Sample records for plaster glue complex

  1. Do You Have Work-Related Asthma? A Guide for You and Your Doctor

    MedlinePlus

    ... Polyurethane foam • Paints, lacquers, ink, varnishes, sealants, finishes • Insulation materials • Polyurethane rubber • Glues and adhesives • Car manufacture and repair • Building construction (plaster, insulation) • Foam blowing and cutting • Painting • Truck bed liner ...

  2. [Propolis. The bee glue as presented by the Graeco-Roman literature].

    PubMed

    Golder, Werner

    2004-01-01

    The bee glue, commonly known as propolis, has been employed for medical purposes already in teh ancient world. More than 15 Greek and Roman authors report on the preparation and application of the so-called third natural product of the bees (besides honey and wax). Aristoteles described the fundamental issues of its biology in his 'Historia Animalium' correctly. The bulk of propolis is obtained from the barks of poplars. Once carried in the hives, the glue is used to stabilize the cells and honeycombs and to protect the bees against invaders and cold weather. Propolis has been chiefly employed for the preparation of ointment and plasters. For this purpose, the viscous raw material was purified, moulded and boiled. In most preparations, the bee glue was only one of many (up to 20) pharmacologically active constituents and came to five to 20% of the mixture. Only rarely, a single drug therapy was using propolis was carried out. The application of the glue was most successful in general surgery and casualties. In that respect, the ancient physicians took advantage of the anti-edematous and anti-infectious properties of the substance. Thus, it was used to treat bumps, indurations, and slow-healing wounds. Moreover, cataplasms against swollen cervical nodes and indurations of the female breast often contained propolis. Finally, bee glue proved successful for the treatment of chronic backache and pain in the hip as well as fresh injuries of muscles and tendons. In the sector of skin diseases, lichens and condylomata were found to respond well to propolis. ALl this indications have been a matter of several records. However, the successful use of propolis in diseases of the stomach and liver has ben reported solely by Alexander of Tralles (6th century AD). Not counting the internal diseases, the spectrum of indications for propolis has not substantially changed as compared to the classical antiquity. Interestingly, radiation therapists have adopted the ancient remedy and use propolis successfully for the treatment of actinic stomatitis and mucositis.

  3. Wall paintings studied using Raman spectroscopy: a comparative study between various assays of cross sections and external layers.

    PubMed

    Perez-Rodriguez, Jose Luis; Robador, Maria Dolores; Centeno, Miguel Angel; Siguenza, Belinda; Duran, Adrian

    2014-01-01

    This work describes a comparative study between in situ applications of portable Raman spectroscopy and direct laboratory measurements using micro-Raman spectroscopy on the surface of small samples and of cross sections. The study was performed using wall paintings from different sites of the Alcazar of Seville. Little information was obtained using a portable Raman spectrometer due to the presence of an acrylic polymer, calcium oxalate, calcite and gypsum that was formed or deposited on the surface. The pigments responsible for different colours, except cinnabar, were not detected by the micro-Raman spectroscopy study of the surface of small samples taken from the wall paintings due to the presence of surface contaminants. The pigments and plaster were characterised using cross sections. The black colour consisted of carbon black. The red layers were formed by cinnabar and white lead or by iron oxides. The green and white colours were composed of green emerald or atacamite and calcite, respectively. Pb3O4 has also been characterised. The white layers (plaster) located under the colour layers consisted of calcite, quartz and feldspars. The fresco technique was used to create the wall paintings. A wall painting located on a gypsum layer was also studied. The Naples yellow in this wall painting was not characterised due to the presence of glue and oils. This study showed the advantage of studying cross sections to completely characterise the pigments and plaster in the studied wall paintings. Copyright © 2013 Elsevier B.V. All rights reserved.

  4. A Water-Borne Adhesive Modeled after the Sandcastle Glue of P. californicaa

    PubMed Central

    Shao, Hui; Bachus, Kent N.

    2010-01-01

    Polyacrylate glue protein analogs of the glue secreted by Phragmatopoma californica, a marine polycheate, were synthesized with phosphate, primary amine, and catechol sidechains with molar ratios similar to the natural glue proteins. Aqueous mixtures of the mimetic polyelectrolytes condensed into liquid complex coacervates around neutral pH. Wet cortical bone specimens bonded with the coacervates, oxidatively crosslinked through catechol sidechains, had bond strengths nearly 40% of the strength of a commercial cyanoacrylate. The unique material properties of complex coacervates may be ideal for development of clinically useful adhesives and other biomaterials. PMID:19040222

  5. Comparison of different techniques for obturating experimental internal resorptive cavities.

    PubMed

    Goldberg, F; Massone, E J; Esmoris, M; Alfie, D

    2000-06-01

    Forty extracted maxillary central incisors were instrumented at the working length to a #50 file. The roots were sectioned transversely with a diamond disk at 7 mm from the anatomical apex. At the opening of the root canal of each section, hemicircular cavities were drilled with a specially designed bur. The corresponding root sections were cemented with glue, thus obtaining root canals with similar cavities that simulated internal resorptions. Teeth were embedded in plaster casts to facilitate their handling. The specimens were randomly separated into four groups of 10. The following obturation techniques were evaluated: lateral compaction (group A), hybrid technique (group B), Obtura II (group C), and Thermafil (group D). AH26 was used as the sealer. After obturation, the plaster was removed and the teeth were radiographed in buccolingual and mesiodistal directions to evaluate the quality of the obturation at the IRC. The incisors were then cut with a scalpel at the same level as the previous section, to examine, under a stereomicroscope, the type of material that filled the IRC. Obtura II gave the best results and in most of the specimens obturated with this technique, the IRC were filled mainly with gutta-percha. Statistical analysis of the data indicated that the differences between group C and the other groups were significant (P < 0.05).

  6. Complex coacervates as a foundation for synthetic underwater adhesives

    PubMed Central

    Stewart, Russell J.; Wang, Ching Shuen; Shao, Hui

    2011-01-01

    Complex coacervation was proposed to play a role in the formation of the underwater bioadhesive of the Sandcastle worm (Phragmatopoma californica) based on the polyacidic and polybasic nature of the glue proteins and the balance of opposite charges at physiological pH. Morphological studies of the secretory system suggested the natural process does not involve complex coacervation as commonly defined. The distinction may not be important because electrostatic interactions likely play an important role in formation of the sandcastle glue. Complex coacervation has also been invoked in the formation of adhesive underwater silk fibers of caddisfly larvae and the adhesive plaques of mussels. A process similar to complex coacervation, that is, condensation and dehydration of biopolyelectrolytes through electrostatic associations, seems plausible for the caddisfly silk. This much is clear, the sandcastle glue complex coacervation model provided a valuable blueprint for the synthesis of a biomimetic, waterborne, underwater adhesive with demonstrated potential for repair of wet tissue. PMID:21081223

  7. Moisture buffer capacity of cement-lime plasters with enhanced thermal storage capacity

    NASA Astrophysics Data System (ADS)

    Fořt, Jan; Pavlíková, Milena; Pavlík, Zbyšek

    2017-07-01

    Indoor air temperature and relative humidity represent important parameters for health and working efficiency of buildings occupants. Beside the moderation of temperature, investigation of hygric properties of building materials with connection to indoor relative humidity variation became recognized as a relevant factor for energy efficient building maintenance. The moisture buffer value introduced in the Nordtest protocol can be used for estimation of moisture buffer capacity of building materials or their multi-layered systems. In this paper, both the ideal and real moisture buffer values are examined on the basis of simulation of diurnal relative humidity fluctuations in plasters with incorporated PCM admixture. Retrieved data points to a complex effect of the tested plasters on possible moderation of buildings interior climate.

  8. Glue detection based on teaching points constraint and tracking model of pixel convolution

    NASA Astrophysics Data System (ADS)

    Geng, Lei; Ma, Xiao; Xiao, Zhitao; Wang, Wen

    2018-01-01

    On-line glue detection based on machine version is significant for rust protection and strengthening in car production. Shadow stripes caused by reflect light and unevenness of inside front cover of car reduce the accuracy of glue detection. In this paper, we propose an effective algorithm to distinguish the edges of the glue and shadow stripes. Teaching points are utilized to calculate slope between the two adjacent points. Then a tracking model based on pixel convolution along motion direction is designed to segment several local rectangular regions using distance. The distance is the height of rectangular region. The pixel convolution along the motion direction is proposed to extract edges of gules in local rectangular region. A dataset with different illumination and complexity shape stripes are used to evaluate proposed method, which include 500 thousand images captured from the camera of glue gun machine. Experimental results demonstrate that the proposed method can detect the edges of glue accurately. The shadow stripes are distinguished and removed effectively. Our method achieves the 99.9% accuracies for the image dataset.

  9. Generalized Likelihood Uncertainty Estimation (GLUE) Using Multi-Optimization Algorithm as Sampling Method

    NASA Astrophysics Data System (ADS)

    Wang, Z.

    2015-12-01

    For decades, distributed and lumped hydrological models have furthered our understanding of hydrological system. The development of hydrological simulation in large scale and high precision elaborated the spatial descriptions and hydrological behaviors. Meanwhile, the new trend is also followed by the increment of model complexity and number of parameters, which brings new challenges of uncertainty quantification. Generalized Likelihood Uncertainty Estimation (GLUE) has been widely used in uncertainty analysis for hydrological models referring to Monte Carlo method coupled with Bayesian estimation. However, the stochastic sampling method of prior parameters adopted by GLUE appears inefficient, especially in high dimensional parameter space. The heuristic optimization algorithms utilizing iterative evolution show better convergence speed and optimality-searching performance. In light of the features of heuristic optimization algorithms, this study adopted genetic algorithm, differential evolution, shuffled complex evolving algorithm to search the parameter space and obtain the parameter sets of large likelihoods. Based on the multi-algorithm sampling, hydrological model uncertainty analysis is conducted by the typical GLUE framework. To demonstrate the superiority of the new method, two hydrological models of different complexity are examined. The results shows the adaptive method tends to be efficient in sampling and effective in uncertainty analysis, providing an alternative path for uncertainty quantilization.

  10. Cutaneous irritancy of an ibuprofen medicated plaster in healthy volunteers.

    PubMed

    Maganji, Manisha; Connolly, Mark P; Bhatt, Aomesh

    2018-01-01

    Ibuprofen is a commonly used non-steroidal anti-inflammatory drug administered to treat injuries, joint pain, and recurrent muscular skeletal pain. The aim of this study was to determine the cutaneous irritancy of a medicated ibuprofen plaster compared with a placebo plaster in healthy volunteers. Healthy volunteers (N = 31) were treated at the same time with one ibuprofen and one placebo plaster. The ibuprofen and placebo plaster were applied in a randomized fashion to sites on the left or right side of subjects' lower backs. At each scheduled visit, the plasters and applications sites were assessed for degree of adhesion and skin irritancy, respectively. The plasters were applied on study Days 1, 2, 3, 5, 8, 10, 12, 15, 17, and 19, with final plaster removal on Day 22. The ibuprofen medicated plaster compared with placebo had a lower percentage of Grade 1 (23.3% vs. 46.7%, respectively), Grade 2 (10% vs. 20%), and ≥Grade 3 (3% vs. 16.1%) irritancy scores after 21 days of application. The mean irritation score across the study was 0.40 for the ibuprofen medicated plaster and 1.18 for the placebo plaster. The irritation score on Day 22 of the study was 0.53 for the ibuprofen medicated plaster and 1.50 for placebo. The placebo plaster was associated with a higher number of stopped applications due to Grade 3 or above skin reactions compared with the ibuprofen medicated plaster (5 vs. 1, respectively). The ibuprofen medicated plaster was well tolerated and was associated with lower irritancy than the placebo plaster.

  11. Cutaneous irritancy of an ibuprofen medicated plaster in healthy volunteers.

    PubMed

    Maganji, Manisha; Connolly, Mark P; Bhatt, Aomesh

    2018-04-01

    To assess the irritation and contact sensitization potential of a 200 mg ibuprofen medicated plaster. This double-blind, phase-1 placebo controlled study had two phases; the induction phase to evaluate the irritant potential of continuous application of the plaster, and the challenge phase to assess contact sensitivity (allergy). The cumulative irritancy potential was evaluated using an adaptation of the Shelanski method. Healthy adults (≥18 years of age) (N = 210) were treated simultaneously with one ibuprofen medicated and one placebo plaster applied in a randomized fashion to either the left or right side of the lower back. During the induction phase, plasters were applied on Days 1, 3, 5, 8, 10, 12, 15, 17, and 19 and the final plaster removed on Day 22. At each scheduled visit plasters and applications sites were assessed for degree of adhesion and skin irritation (score of 1 = no irritation to 7 = strong reaction spreading beyond test sites), respectively. The challenge phase followed a two-week washout period. A plaster was applied on Day 36 for 48 h and assessment occurred on Days 38, 39, and 40. The mean cumulative irritation score during the induction phase was lower for the ibuprofen medicated plaster than the placebo plaster (0.32 vs. 1.23, respectively). Three (1.4%) subjects experience a dermal reaction of grade ≥3 for the ibuprofen medicated plaster compared with 27 (12.7%) for the placebo plaster. Following challenge with ibuprofen or placebo plasters, 12 subjects (6.2%) with the ibuprofen medicated plaster and four (2.2%) with the placebo plaster had skin reaction of assessment grade higher than the induction phase. One subject for the ibuprofen and two for the placebo plaster had reactions with grade >2. No subjects showed an increase in sensitization on Day 39 or 40 compared with Day 38. The findings indicate that the both the irritancy and contact sensitization of the ibuprofen medicated plaster is acceptable.

  12. Minimizing Collateral Brain Injury Using a Protective Layer of Fibrin Glue: Technical Note.

    PubMed

    Basma, Jaafar; Latini, Francesco; Ryttlefors, Mats; Abuelem, Tarek; Krisht, Ali Fadl

    2015-12-01

    Neurosurgical procedures expose the brain surface to a constant risk of collateral injury. We describe a technique where the brain surface is covered with a protective layer of fibrin glue and discuss its advantages. A thin layer of fibrin glue was applied on the brain surface after its exposure in 34 patients who underwent different craniotomies for tumoral and vascular lesions. Data of 35 more patients who underwent standard microsurgical technique were collected as a control group. Cortical and pial injuries were evaluated using an intraoperative visual scale. Eventual abnormal signals at the early postoperative T2-weighted fluid-attenuated inversion recovery (T2FLAIR) magnetic resonance imaging (MRI) sequences were evaluated in oncological patients. Total pial injury was noted in 63% of cases where fibrin glue was not used. In cases where fibrin glue was applied, a significantly lower percentage of 26% (P < 0.01) had pial injuries. Only 9% had injuries in areas covered with fibrin glue (P < 0.0001). Early postoperative T2FLAIR MRI confirmed the differences of altered signal around the surgical field in the two populations. We propose beside an appropriate and careful microsurgical technique the possible use of fibrin glue as alternative, safe, and helpful protection during complex microsurgical dissections. Its intrinsic features allow the neurosurgeon to minimize the cortical manipulation preventing minor collateral brain injury. Copyright © 2015 Elsevier Inc. All rights reserved.

  13. Comparison of effects of seven treatment methods for distal radius fracture on minimizing complex regional pain syndrome

    PubMed Central

    Sun, Tao

    2016-01-01

    Introduction Using network meta-analysis, we evaluated the adverse effects of the seven most common treatment methods, i.e., bridging external fixation, non-bridging external fixation, K-wire fixation, plaster fixation, dorsal plating, volar plating, and dorsal and volar plating, by their associated risk of developing complex regional pain syndrome (CRPS) in distal radius fracture (DRF) patients. Material and methods Following an exhaustive search of scientific literature databases for high quality studies, randomized controlled trials (RCTs) related to our study topic were screened and selected based on stringent predefined inclusion and exclusion criteria. Data extracted from the selected studies were used for statistical analyses using Stata 12.0 software. Results A total of 17 RCTs, including 1658 DRF patients, were enrolled in this network meta-analysis. Among the 1658 DRF patients, 452 received bridging external fixation, 525 received non-bridging external fixation, 154 received K-wire fixation, 84 received plaster fixation, 132 received dorsal plating, 123 received volar plating, and 188 received dorsal and volar plating. When compared to bridging external fixation patients, there was no marked difference in the CRPS risk in DRF patients receiving different treatments (all p > 0.05). However, the surface under the cumulative ranking curves (SUCRA) for plaster fixation (77.0%) and non-bridging external fixation (71.3%) were significantly higher compared with the other five methods. Conclusions Our findings suggest that compared with bridging external fixation, K-wire fixation, dorsal plating, volar plating, dorsal and volar plating, plaster fixation and non-bridging external fixation might be the better treatment methods to reduce the risk of CRPS in DRF patients. PMID:28144268

  14. Refractory ceramic has wide usage, low fabrication cost

    NASA Technical Reports Server (NTRS)

    1964-01-01

    Particulate, fused amorphous silica is formed into complex shapes by casting in plaster molds. High temperature firing is not required. This ceramic is resistant to thermal shock and exhibits good strength properties.

  15. Effect of fibrin glue occlusion of the hepatobiliary tract on thioacetamide-induced liver failure.

    PubMed

    Schmandra, T C; Bauer, H; Petrowsky, H; Herrmann, G; Encke, A; Hanisch, E

    2001-07-01

    Expression and activation of hepatocyte growth factor (HGF) is stimulated by a complex system of interacting proteins, with thrombin playing an initial role in this process. The impact of temporary occlusion of the hepatobiliary tract with fibrin glue (major component thrombin) on the HGF system in acute and chronic liver damage in a rat model was investigated. Chronic liver damage was induced in 40 rats by daily intraperitoneal application of thioacetamide (100 mg/kg) for 14 days. After 7 days half of them received an injection of 0.2 mL fibrin glue into the hepatobiliary system. Daily intraperitoneal administration of thioacetamide continued for 7 consecutive days. The rats were then sacrificed for blood and tissue analysis. Acute liver failure was induced in 12 rats by intraperitoneal administration of a lethal dose of thioacetamide (500 mg/kg per day for 3 days) after an injection with 0.2 mL fibrin glue into their hepatobiliary tract. Survival rates and histological outcome were investigated and compared with control animals. Fibrin glue occluded rats showed significantly lower liver enzyme activities and serum levels of bilirubin, creatinine and urea nitrogen. Immunohistochemistry revealed a significant increase in c-met-, HGFalpha- and especially HGFbeta-positive cells. Rats subjected to a lethal dose of thioacetamide survived when fibrin glue was applied 24 hours prior to the toxic challenge. These animals showed normal liver structure and no clinical abnormalities. Fibrin glue occlusion of the hepatobiliary tract induces therapeutic and prophylactic effects on chronic and acute liver failure by stimulating the HGF system. Therefore, fibrin glue occlusion might be useful in treating toxic liver failure.

  16. Evaluation of Potential Damage to Unconventional Structures by Sonic Booms

    DTIC Science & Technology

    1990-05-01

    plaster and gypsum board caused by sonic boom is broken...on wood lath 3.3 5.6 2. Plaster on gyplath 7.5 16 3. Plaster on expanded metal lath 16 16 4. Plaster on concrete block 16 16 5. Gypsum board (new) 16... wallboard (also called plasterboard or drywall), it is assumed that interior walls of unconventional historic wood frame buildings used plaster instead.

  17. Fibrin glue mixed with platelet-rich fibrin as a scaffold seeded with dental bud cells for tooth regeneration.

    PubMed

    Yang, Kai-Chiang; Wang, Chun-Hao; Chang, Hao-Hueng; Chan, Wing P; Chi, Chau-Hwa; Kuo, Tzong-Fu

    2012-11-01

    Odontogenesis is a complex process with a series of epithelial-mesenchymal interactions and odontogenic molecular cascades. In tissue engineering of teeth from stem cells, platelet-rich fibrin (PRF), which is rich in growth factors and cytokines, may improve regeneration. Accordingly, PRF was added into fibrin glue to enrich the microenvironment with growth factors. Unerupted second molar tooth buds were harvested from miniature swine and cultured in vitro for 3 weeks to obtain dental bud cells (DBCs). Whole blood was collected for the preparation of PRF and fibrin glue before surgery. DBCs were suspended in fibrin glue and then enclosed with PRF, and the DBC-fibrin glue-PRF composite was autografted back into the original alveolar sockets. Radiographic and histological examinations were used to identify the regenerated tooth structure 36 weeks after implantation. Immunohistochemical staining was used to detect proteins specific to tooth regeneration. One pig developed a complete tooth with crown, root, pulp, enamel, dentin, odontoblast, cementum, blood vessels, and periodontal ligaments in indiscriminate shape. Another animal had an unerupted tooth that expressed cytokeratin 14, dentin matrix protein-1, vascular endothelial growth factor, and osteopontin. This study demonstrated, using autogenic cell transplantation in a porcine model, that DBCs seeded into fibrin glue-PRF could regenerate a complete tooth. Copyright © 2011 John Wiley & Sons, Ltd.

  18. A Biological Tissue Adhesive and Dissolvent System for Intraocular Tumor Plaque Brachytherapy.

    PubMed

    Zloto, Ofira; Vishnevskia-Dai, Vicktoria; Moisseiev, Joseph; Belkin, Michael; Fabian, Ido Didi

    2016-02-01

    To examine a novel technique for simplified placement and removal of plaque brachytherapy by fibrin glue and urokinase (medac Gmbh, Hamburg, Germany). In six enucleated porcine eyes, plaques were placed on the episclera and fibrin glue was applied to cover it. Urokinase was used to dissolve the glue in three eyes and saline was used in three eyes. Adhesion strength was measured further on 15 plaques affixed to porcine eyes (glued in five with intact conjunctiva, glued in five with removed conjunctiva, and sutured in five). Saline had no effect on the glue-plaque-eye complex, whereas the urokinase (0.38 mL ± 0.08 mL) easily dissolved the adhesion between the glue layer and surrounding tissues. The weight required to detach the plaques was 0.349 kg ± 0.173 kg for glued eyes with intact conjunctiva, 0.405 kg ± 0.083 kg for sutured eyes (P = .59), and 0.032 kg ± 0.004 kg for glued eyes without intact conjunctiva (P ≤ .015). The usage of the biological adhesive and dissolvent system was applicable for plaque surgery in an ex vivo animal model. Copyright 2016, SLACK Incorporated.

  19. Possibility of reconstruction of dental plaster cast from 3D digital study models

    PubMed Central

    2013-01-01

    Objectives To compare traditional plaster casts, digital models and 3D printed copies of dental plaster casts based on various criteria. To determine whether 3D printed copies obtained using open source system RepRap can replace traditional plaster casts in dental practice. To compare and contrast the qualities of two possible 3D printing options – open source system RepRap and commercially available 3D printing. Design and settings A method comparison study on 10 dental plaster casts from the Orthodontic department, Department of Stomatology, 2nd medical Faulty, Charles University Prague, Czech Republic. Material and methods Each of 10 plaster casts were scanned by inEos Blue scanner and the printed on 3D printer RepRap [10 models] and ProJet HD3000 3D printer [1 model]. Linear measurements between selected points on the dental arches of upper and lower jaws on plaster casts and its 3D copy were recorded and statistically analyzed. Results 3D printed copies have many advantages over traditional plaster casts. The precision and accuracy of the RepRap 3D printed copies of plaster casts were confirmed based on the statistical analysis. Although the commercially available 3D printing enables to print more details than the RepRap system, it is expensive and for the purpose of clinical use can be replaced by the cheaper prints obtained from RepRap printed copies. Conclusions Scanning of the traditional plaster casts to obtain a digital model offers a pragmatic approach. The scans can subsequently be used as a template to print the plaster casts as required. Using 3D printers can replace traditional plaster casts primarily due to their accuracy and price. PMID:23721330

  20. Acute and chronic glue sniffing effects and consequences of withdrawal on aggressive behavior.

    PubMed

    Bouchatta, Otmane; Ouhaz, Zakaria; Ba-Mhamed, Saadia; Kerekes, Nóra; Bennis, Mohamed

    2016-05-01

    Drug abuse act on brain mechanisms that cause a high-risk individual to engage in aggressive and violent behavior. While a drug-violence relationship exists, the nature of this relationship is often complex, with intoxication, neurotoxic, and withdrawal effects often being confused and/or confounded. Glue sniffing is often a springboard to the abuse of more addictive drugs. Despite its high prevalence and serious consequences, we know relatively little about the aggressive behavioral effects of volatile inhalants abuse, especially glue. The aim of the present study was to investigate the link between the duration of glue exposure, a common substance abuse problem in Morocco, and the level of aggressive behavior during withdrawal. For this we used the isolation-induced aggression model "residents" in three groups of mice. The first group served as control resident animals (n=10, without exposure); the second group as experimental resident mice (n=10) tested before and after acute (first day) and chronic exposure to the glue, and at 1 and 2weeks of withdrawal; and the third group of 10 intruder animals. The results showed that the number of attacks decreased (halved) and the latency of the first attack increased (doubled) following acute glue sniffing. However, the effects of chronic exposure and of 1week of withdrawal led to an increase in the intensity of agonistic encounters. After 2weeks of withdrawal, the intensity of aggressive behavior decreased again. These results indicated that chronic glue exposure and the first week of withdrawal are associated with increased aggression in mice. Copyright © 2016 Elsevier Inc. All rights reserved.

  1. A chemical rationalization of the processing and application of the mortar coatings: Structural, thermodynamic, and fluorescence properties

    NASA Astrophysics Data System (ADS)

    Lima, Nathan B.; Rogerio, V. A.; Belarmino, Marcia K. D. L.; Silva, Anderson I. S.; Ioras, Renan U. F.; Oliveira, Romilde A.; Lima, Nathalia B. D.

    2018-07-01

    A chemical rationalization of the processing and application of the roughcast and plaster mortar coatings was advanced. The results revealed that the structural and thermodynamic nature of the hydrogen-bonded complexes between the inorganic precursors and water molecules are associated with the physical properties of both coatings. In this sense, the workability and curing time of the roughcast and the plaster mortars studied, seemingly, are related to the nature of the water solvation in the main components of these materials: calcium hydroxide and silicon dioxide. In addition, PM7 and PM7/COSMO results indicate that the enthalpy of solvation of water by hydrogen bonds in calcium hydroxide is stronger when compared with silicon dioxide systems. Therefore, the presence of free hydrated lime (calcium hydroxide) in the precursor mixture of plaster mortar leads to the large workability and elapsed curing time of this material. On the other hand, the absence of free hydrated lime in the precursor mixture of the roughcast mortar leads to its poor workability and faster elapsed curing time. Further, fluorescence microscopy experiments revealed that the inorganic compounds present in the cement precursor were transformed into different materials, that exhibit red and blue fluorescence. Finally, mechanical tests showed a tensile strength average 0.67 MPa for the plaster mortar material, whereas for the roughcast material is 0.53 MPa.

  2. Numerical simulation of temperature at drilling micro-hole on moving CO2 laser irradiated sticking plaster

    NASA Astrophysics Data System (ADS)

    Rao, Zhiming; He, Zhifang; Du, Jianqiang; Zhang, Xinyou; Ai, Guoping; Zhang, Chunqiang; Wu, Tao

    2012-03-01

    This paper applied numerical simulation of temperature by using finite element analysis software Ansys to study a model of drilling on sticking plaster. The continuous CO2 laser doing uniform linear motion and doing uniform circular motion irradiated sticking plaster to vaporize. The sticking plaster material was chosen as the thermal conductivity, the heat capacity and the density. For temperatures above 450 °C, sticking plaster would be vaporized. Based on the mathematical model of heat transfer, the process of drilling sticking plaster by laser beams could be simulated by Ansys. The simulation results showed the distribution of the temperature at the surface of the sticking plaster with the time of vaporizing at CO2 laser to do uniform linear motion and to do uniform circular motion. The temperature of sticking plaster CO2 laser to do uniform linear motion was higher than CO2 laser to do uniform circular motion in the same condition.

  3. Plaster-based magnetite composite materials in construction

    NASA Astrophysics Data System (ADS)

    Klimenko, V. G.; Kashin, G. A.; Prikaznova, T. A.

    2018-03-01

    Calculation and experimental data demonstrate the possibility of using iron-ore concentrate of Lebedinsky Mining and Processing Plant (Lebedinsky GOK) in the production of plaster concrete. Their physical-mechanical, thermal and radiation protective properties were studied. Structurization mechanisms in plaster magnetite systems depending on the type of plaster binder, textures and the structure of plaster crystals providing for the design of composite materials with predetermined properties are suggested. Composite materials to ensure protection against X-ray radiation are obtained.

  4. Comparison of the spatial landmark scatter of various 3D digitalization methods.

    PubMed

    Boldt, Florian; Weinzierl, Christian; Hertrich, Klaus; Hirschfelder, Ursula

    2009-05-01

    The aim of this study was to compare four different three-dimensional digitalization methods on the basis of the complex anatomical surface of a cleft lip and palate plaster cast, and to ascertain their accuracy when positioning 3D landmarks. A cleft lip and palate plaster cast was digitalized with the SCAN3D photo-optical scanner, the OPTIX 400S laser-optical scanner, the Somatom Sensation 64 computed tomography system and the MicroScribe MLX 3-axis articulated-arm digitizer. First, four examiners appraised by individual visual inspection the surface detail reproduction of the three non-tactile digitalization methods in comparison to the reference plaster cast. The four examiners then localized the landmarks five times at intervals of 2 weeks. This involved simply copying, or spatially tracing, the landmarks from a reference plaster cast to each model digitally reproduced by each digitalization method. Statistical analysis of the landmark distribution specific to each method was performed based on the 3D coordinates of the positioned landmarks. Visual evaluation of surface detail conformity assigned the photo-optical digitalization method an average score of 1.5, the highest subjectively-determined conformity (surpassing computer tomographic and laser-optical methods). The tactile scanning method revealed the lowest degree of 3D landmark scatter, 0.12 mm, and at 1.01 mm the lowest maximum 3D landmark scatter; this was followed by the computer tomographic, photo-optical and laser-optical methods (in that order). This study demonstrates that the landmarks' precision and reproducibility are determined by the complexity of the reference-model surface as well as the digital surface quality and individual ability of each evaluator to capture 3D spatial relationships. The differences in the 3D-landmark scatter values and lowest maximum 3D-landmark scatter between the best and the worst methods showed minor differences. The measurement results in this study reveal that it is not the method's precision but rather the complexity of the object analysis being planned that should determine which method is ultimately employed.

  5. Accuracy of three-dimensional dental resin models created by fused deposition modeling, stereolithography, and Polyjet prototype technologies: A comparative study.

    PubMed

    Rebong, Raymund E; Stewart, Kelton T; Utreja, Achint; Ghoneima, Ahmed A

    2018-05-01

    The aim of this study was to assess the dimensional accuracy of fused deposition modeling (FDM)-, Polyjet-, and stereolithography (SLA)-produced models by comparing them to traditional plaster casts. A total of 12 maxillary and mandibular posttreatment orthodontic plaster casts were selected from the archives of the Orthodontic Department at the Indiana University School of Dentistry. Plaster models were scanned, saved as stereolithography files, and printed as physical models using three different three-dimensional (3D) printers: Makerbot Replicator (FDM), 3D Systems SLA 6000 (SLA), and Objet Eden500V (Polyjet). A digital caliper was used to obtain measurements on the original plaster models as well as on the printed resin models. Comparison between the 3D printed models and the plaster casts showed no statistically significant differences in most of the parameters. However, FDM was significantly higher on average than were plaster casts in maxillary left mixed plane (MxL-MP) and mandibular intermolar width (Md-IMW). Polyjet was significantly higher on average than were plaster casts in maxillary intercanine width (Mx-ICW), mandibular intercanine width (Md-ICW), and mandibular left mixed plane (MdL-MP). Polyjet was significantly lower on average than were plaster casts in maxillary right vertical plane (MxR-vertical), maxillary left vertical plane (MxL-vertical), mandibular right anteroposterior plane (MdR-AP), mandibular right vertical plane (MdR-vertical), and mandibular left vertical plane (MdL-vertical). SLA was significantly higher on average than were plaster casts in MxL-MP, Md-ICW, and overbite. SLA was significantly lower on average than were plaster casts in MdR-vertical and MdL-vertical. Dental models reconstructed by FDM technology had the fewest dimensional measurement differences compared to plaster models.

  6. The complex leaves of the monkey's comb (Amphilophium crucigerum, Bignoniaceae): a climbing strategy without glue.

    PubMed

    Seidelmann, Katrin; Melzer, Björn; Speck, Thomas

    2012-11-01

    Monkey's comb (Amphilophium crucigerum) is a widely spread neotropical leaf climber that develops attachment pads for anchorage. A single complex leaf of the species comprises a basal pair of foliate, assimilating leaflets and apical, attaching leaflet tendrils. This study aims to analyze these leaves and their ontogenetic development for a better understanding of the attachment process, the form-structure-function relationships involved, and the overall maturation of the leaves. Thorough morphometrical, morphological, and anatomical analyses incorporated high-resolution microscopy, various staining techniques, SEM, and photographic recordings over the entire ontogenetic course of leaf development. The foliate, assimilating leaflets and the anchorage of the more apical leaflet tendrils acted independently of each other. Attachment was achieved by coiling of the leaflet tendrils and/or development of attachment pads at the tendril apices that grow opportunistically into gaps and fissures of the substrate. In contact zones with the substrate, the cells of the pads differentiate into a vessel element-like tissue. During the entire attachment process of the plant, no glue was excreted. The complex leaves of monkey's comb are highly differentiated organs with specialized leaf parts whose functions-photosynthesis or attachment-work independently of each other. The function of attachment includes coiling and maturation process of the leaflet tendrils and the formation of attachment pads, resulting in a biomechanically sound and persistent anchorage of the plant without the need of glue excretion. This kind of glue-less attachment is not only of interest in the framework of analyzing the functional variety of attachment structures evolved in climbing plants, but also for the development of innovative biomimetic attachment structures for manifold technical applications.

  7. Calcified lesion modeling for excimer laser ablation

    NASA Astrophysics Data System (ADS)

    Scott, Holly A.; Archuleta, Andrew; Splinter, Robert

    2009-06-01

    Objective: Develop a representative calcium target model to evaluate penetration of calcified plaque lesions during atherectomy procedures using 308 nm Excimer laser ablation. Materials and Methods: An in-vitro model representing human calcified plaque was analyzed using Plaster-of-Paris and cement based composite materials as well as a fibrinogen model. The materials were tested for mechanical consistency. The most likely candidate(s) resulting from initial mechanical and chemical screening was submitted for ablation testing. The penetration rate of specific multi-fiber catheter designs and a single fiber probe was obtained and compared to that in human cadaver calcified plaque. The effects of lasing parameters and catheter tip design on penetration speed in a representative calcified model were verified against the results in human cadaver specimens. Results: In Plaster of Paris, the best penetration was obtained using the single fiber tip configuration operating at 100 Fluence, 120 Hz. Calcified human lesions are twice as hard, twice as elastic as and much more complex than Plaster of Paris. Penetration of human calcified specimens was highly inconsistent and varied significantly from specimen to specimen and within individual specimens. Conclusions: Although Plaster of Paris demonstrated predictable increases in penetration with higher energy density and repetition rate, it can not be considered a totally representative laser ablation model for calcified lesions. This is in part due to the more heterogeneous nature and higher density composition of cadaver intravascular human calcified occlusions. Further testing will require a more representative model of human calcified lesions.

  8. Plaster of Paris–Short History of Casting and Injured Limb Immobilzation

    PubMed Central

    Szostakowski, B.; Smitham, P.; Khan, W.S.

    2017-01-01

    Various materials have been used since ancient times to help immobilise fractures. In this review, we discuss the history and developments of these materials as well as plaster of Paris. There has been a recent trend away from non-operative management of fractures, and skills in the use of plaster of Paris are declining. For the successful treatment of patients, it is important to appreciate how plaster works, how it should be used, and what can go wrong. In this review, we also discuss principles of applications and complications of plaster of Paris. PMID:28567158

  9. Efficacy and tolerability of a new ibuprofen 200mg plaster in patients with acute sports-related traumatic blunt soft tissue injury/contusion.

    PubMed

    Predel, Hans-Georg; Giannetti, Bruno; Connolly, Mark P; Lewis, Fraser; Bhatt, Aomesh

    2018-01-01

    Ibuprofen is used for the treatment of non-serious pain. This study assessed the efficacy and safety of a new ibuprofen plaster for the treatment of pain associated with acute sports impact injuries/contusions. In this randomised, double-blind, multi-centre, placebo controlled, parallel group study, adults (n = 130; 18-58 years of age) diagnosed with acute sports-related blunt soft tissue injury/contusion were randomized to receive either ibuprofen 200 mg plaster or placebo plaster. Plasters were administered once daily for five consecutive days. The primary assessment was area under the visual analogue scale (VAS) of pain on movement (POM) over 0 to three days (VAS AUC 0-3d ). Other endpoints included algometry AUC from 0 to three days (AUC 0-3d ) and 0 to five days (AUC 0-5d ), to evaluate improvement of sensitivity at the injured site, and patient and investigator global assessment of efficacy. Safety was monitored throughout the study. The ibuprofen plaster resulted in superior reduction in AUC 0-3d compared with placebo; the Least Squares (LS) mean difference was 662.82 mm*h in favour of the ibuprofen 200mg plaster (P = 0.0011). The greater improvement in VAS AUC of POM was also observed after 12 h, 24 h, and five days of therapy. Tenderness also significantly improved with the ibuprofen plaster compared with placebo; LS mean difference in algometry/tenderness AUC 0-3d was 1.87 N/cm 2 *d and AUC 0-5d was 1.87 N/cm 2 *d (P values ≤0.0004). At all study timepoints, a greater percentage of patients and investigators rated the effectiveness of the ibuprofen 200 mg plaster as good/excellent than the placebo plaster. Treatment-emergent adverse events for the ibuprofen plaster were few (≤1.5%) and were mild in severity. The results of this study indicate 200 mg plaster is effective and safe for the treatment of pain due to acute sports-related traumatic blunt soft tissue injury/contusion in adults.

  10. Using CV-GLUE procedure in analysis of wetland model predictive uncertainty.

    PubMed

    Huang, Chun-Wei; Lin, Yu-Pin; Chiang, Li-Chi; Wang, Yung-Chieh

    2014-07-01

    This study develops a procedure that is related to Generalized Likelihood Uncertainty Estimation (GLUE), called the CV-GLUE procedure, for assessing the predictive uncertainty that is associated with different model structures with varying degrees of complexity. The proposed procedure comprises model calibration, validation, and predictive uncertainty estimation in terms of a characteristic coefficient of variation (characteristic CV). The procedure first performed two-stage Monte-Carlo simulations to ensure predictive accuracy by obtaining behavior parameter sets, and then the estimation of CV-values of the model outcomes, which represent the predictive uncertainties for a model structure of interest with its associated behavior parameter sets. Three commonly used wetland models (the first-order K-C model, the plug flow with dispersion model, and the Wetland Water Quality Model; WWQM) were compared based on data that were collected from a free water surface constructed wetland with paddy cultivation in Taipei, Taiwan. The results show that the first-order K-C model, which is simpler than the other two models, has greater predictive uncertainty. This finding shows that predictive uncertainty does not necessarily increase with the complexity of the model structure because in this case, the more simplistic representation (first-order K-C model) of reality results in a higher uncertainty in the prediction made by the model. The CV-GLUE procedure is suggested to be a useful tool not only for designing constructed wetlands but also for other aspects of environmental management. Copyright © 2014 Elsevier Ltd. All rights reserved.

  11. A direct biocombinatorial strategy toward next generation, mussel-glue inspired saltwater adhesives.

    PubMed

    Wilke, Patrick; Helfricht, Nicolas; Mark, Andreas; Papastavrou, Georg; Faivre, Damien; Börner, Hans G

    2014-09-10

    Biological materials exhibit remarkable, purpose-adapted properties that provide a source of inspiration for designing new materials to meet the requirements of future applications. For instance, marine mussels are able to attach to a broad spectrum of hard surfaces under hostile conditions. Controlling wet-adhesion of synthetic macromolecules by analogue processes promises to strongly impact materials sciences by offering advanced coatings, adhesives, and glues. The de novo design of macromolecules to mimic complex aspects of mussel adhesion still constitutes a challenge. Phage display allows material scientists to design specifically interacting molecules with tailored affinity to material surfaces. Here, we report on the integration of enzymatic processing steps into phage display biopanning to expand the biocombinatorial procedure and enable the direct selection of enzymatically activable peptide adhesion domains. Adsorption isotherms and single molecule force spectroscopy show that those de novo peptides mimic complex aspects of bioadhesion, such as enzymatic activation (by tyrosinase), the switchability from weak to strong binders, and adsorption under hostile saltwater conditions. Furthermore, peptide-poly(ethylene oxide) conjugates are synthesized to generate protective coatings, which possess anti-fouling properties and suppress irreversible interactions with blood-plasma protein cocktails. The extended phage display procedure provides a generic way to non-natural peptide adhesion domains, which not only mimic nature but also improve biological sequence sections extractable from mussel-glue proteins. The de novo peptides manage to combine several tasks in a minimal 12-mer sequence and thus pave the way to overcome major challenges of technical wet glues.

  12. 6. Cement and Plaster Warehouse, interior. View looking south. Original ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    6. Cement and Plaster Warehouse, interior. View looking south. Original wood roof truss can be seen at upper left. - Curtis Wharf, Cement & Plaster Warehouse, O & Second Streets, Anacortes, Skagit County, WA

  13. 4. Cement and Plaster Warehouse, southeast corner, showing alterations; pent ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    4. Cement and Plaster Warehouse, southeast corner, showing alterations; pent roof, window and door openings, siding, brick foundation sheathing. - Curtis Wharf, Cement & Plaster Warehouse, O & Second Streets, Anacortes, Skagit County, WA

  14. 3. Cement and Plaster Warehouse, north facade. Loading ramp on ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    3. Cement and Plaster Warehouse, north facade. Loading ramp on the right. Utility building, intrusion, on the far right. - Curtis Wharf, Cement & Plaster Warehouse, O & Second Streets, Anacortes, Skagit County, WA

  15. Antihyperalgesic efficacy of 5% lidocaine medicated plaster in capsaicin and sunburn pain models--two randomized, double-blinded, placebo-controlled crossover trials in healthy volunteers.

    PubMed

    Gustorff, Burkhard; Hauer, David; Thaler, Johannes; Seis, Astrid; Draxler, Julia

    2011-12-01

    The aim of this research is to analyze analgesic efficacy of the 5% lidocaine medicated plaster in two randomized, double-blinded, placebo-controlled, crossover studies in 16 healthy volunteers using capsaicin and sunburn pain models. Lidocaine and placebo plasters were simultaneously applied to forearms and thighs at contralateral body sites for three alternating 12-h plaster-on/plaster-off periods. Between the second and third plaster-on period, 4.2-cm circular spots on both pretreated thighs were irradiated with three times the individual minimal erythema dose of UVB light. After the last plaster-on period, 20 μl of 0.1% capsaicin was injected intradermally into both forearms. The study was repeated using a single 12-h plaster application. The area of pinprick hyperalgesia was diminished by 53% (p < 0.003) in the capsaicin model and by 84% (p < 0.0001) in the sunburn model; the intensity of mechanical hyperalgesia to rigid filaments (8 - 512 mN) was reduced in both models. Cold pain perception threshold was reduced (19.7°C ± 8.0 vs 21.8°C ± 6.8 for placebo, p < 0.05, sunburn). Similar effects were observed in the 12-h exposure study. No effect was seen on capsaicin-induced spontaneous pain and flare size, or blood flow in the sunburn area, and heat hyperalgesia in either study. Lidocaine plaster effectively treats mechanical hyperalgesia and cold pain.

  16. Cross-linking by protein oxidation in the rapidly setting gel-based glues of slugs.

    PubMed

    Bradshaw, Andrew; Salt, Michael; Bell, Ashley; Zeitler, Matt; Litra, Noelle; Smith, Andrew M

    2011-05-15

    The terrestrial slug Arion subfuscus secretes a glue that is a dilute gel with remarkable adhesive and cohesive strength. The function of this glue depends on metals, raising the possibility that metal-catalyzed oxidation plays a role. The extent and time course of protein oxidation was measured by immunoblotting to detect the resulting carbonyl groups. Several proteins, particularly one with a relative molecular mass (M(r)) of 165 x 10³, were heavily oxidized. Of the proteins known to distinguish the glue from non-adhesive mucus, only specific size variants were oxidized. The oxidation appears to occur within the first few seconds of secretion. Although carbonyls were detected by 2,4-dinitrophenylhydrazine (DNPH) in denatured proteins, they were not easily detected in the native state. The presence of reversible cross-links derived from carbonyls was tested for by treatment with sodium borohydride, which would reduce uncross-linked carbonyls to alcohols, but stabilize imine bonds formed by carbonyls and thus lead to less soluble complexes. Consistent with imine bond formation, sodium borohydride led to a 20-35% decrease in the amount of soluble protein with a M(r) of 40-165 (x 10³) without changing the carbonyl content per protein. In contrast, the nucleophile hydroxylamine, which would competitively disrupt imine bonds, increased protein solubility in the glue. Finally, the primary amine groups on a protein with a M(r) of 15 x 10³ were not accessible to acid anhydrides. The results suggest that cross-links between aldehydes and primary amines contribute to the cohesive strength of the glue.

  17. Cross-linking by protein oxidation in the rapidly setting gel-based glues of slugs

    PubMed Central

    Bradshaw, Andrew; Salt, Michael; Bell, Ashley; Zeitler, Matt; Litra, Noelle; Smith, Andrew M.

    2011-01-01

    SUMMARY The terrestrial slug Arion subfuscus secretes a glue that is a dilute gel with remarkable adhesive and cohesive strength. The function of this glue depends on metals, raising the possibility that metal-catalyzed oxidation plays a role. The extent and time course of protein oxidation was measured by immunoblotting to detect the resulting carbonyl groups. Several proteins, particularly one with a relative molecular mass (Mr) of 165×103, were heavily oxidized. Of the proteins known to distinguish the glue from non-adhesive mucus, only specific size variants were oxidized. The oxidation appears to occur within the first few seconds of secretion. Although carbonyls were detected by 2,4-dinitrophenylhydrazine (DNPH) in denatured proteins, they were not easily detected in the native state. The presence of reversible cross-links derived from carbonyls was tested for by treatment with sodium borohydride, which would reduce uncross-linked carbonyls to alcohols, but stabilize imine bonds formed by carbonyls and thus lead to less soluble complexes. Consistent with imine bond formation, sodium borohydride led to a 20–35% decrease in the amount of soluble protein with a Mr of 40–165 (×103) without changing the carbonyl content per protein. In contrast, the nucleophile hydroxylamine, which would competitively disrupt imine bonds, increased protein solubility in the glue. Finally, the primary amine groups on a protein with a Mr of 15×103 were not accessible to acid anhydrides. The results suggest that cross-links between aldehydes and primary amines contribute to the cohesive strength of the glue. PMID:21525316

  18. The topical 5% lidocaine medicated plaster in localized neuropathic pain: a reappraisal of the clinical evidence

    PubMed Central

    de León-Casasola, Oscar A; Mayoral, Victor

    2016-01-01

    Topical 5% lidocaine medicated plasters represent a well-established first-line option for the treatment of peripheral localized neuropathic pain (LNP). This review provides an updated overview of the clinical evidence (randomized, controlled, and open-label clinical studies, real-life daily clinical practice, and case series). The 5% lidocaine medicated plaster effectively provides pain relief in postherpetic neuralgia, and data from a large open-label controlled study indicate that the 5% lidocaine medicated plaster is as effective as systemic pregabalin in postherpetic neuralgia and painful diabetic polyneuropathy but with an improved tolerability profile. Additionally, improved analgesia and fewer side effects were experienced by patients treated synchronously with the 5% lidocaine medicated plaster, further demonstrating the value of multimodal analgesia in LNP. The 5% lidocaine medicated plaster provides continued benefit after long-term (≤7 years) use and is also effective in various other LNP conditions. Minor application-site reactions are the most common adverse events associated with the 5% lidocaine medicated plaster; there is minimal risk of systemic adverse events and drug–drug interactions. Although further well-controlled studies are warranted, the 5% lidocaine medicated plaster is efficacious and safe in LNP and may have particular clinical benefit in elderly and/or medically compromised patients because of the low incidence of adverse events. PMID:26929664

  19. Air Permeability of Renovation Plasters Evaluated with Torrent’s Method

    NASA Astrophysics Data System (ADS)

    Brasse, Krystian; Tracz, Tomasz

    2017-10-01

    The aim of research was to determine the air permeability of the renovation plasters, using Torrent’s method. The scope of this research included three renovation plaster systems. Each of them was applied on experimental, masonry element and had a different rendering coat. Permeability measurements were performed after 28 days of curing in a natural state. In order to calculate the coefficient of air permeability (kT), the partial data was registered during the measurements. The test results indicate the possibility of determination the coefficient of air permeability kT in relation to the renovation plasters. At the same time results confirm the high porosity of the renovation plasters.

  20. Separation of overlapping dental arch objects using digital records of illuminated plaster casts.

    PubMed

    Yadollahi, Mohammadreza; Procházka, Aleš; Kašparová, Magdaléna; Vyšata, Oldřich; Mařík, Vladimír

    2015-07-11

    Plaster casts of individual patients are important for orthodontic specialists during the treatment process and their analysis is still a standard diagnostical tool. But the growing capabilities of information technology enable their replacement by digital models obtained by complex scanning systems. This paper presents the possibility of using a digital camera as a simple instrument to obtain the set of digital images for analysis and evaluation of the treatment using appropriate mathematical tools of image processing. The methods studied in this paper include the segmentation of overlapping dental bodies and the use of different illumination sources to increase the reliability of the separation process. The circular Hough transform, region growing with multiple seed points, and the convex hull detection method are applied to the segmentation of orthodontic plaster cast images to identify dental arch objects and their sizes. The proposed algorithm presents the methodology of improving the accuracy of segmentation of dental arch components using combined illumination sources. Dental arch parameters and distances between the canines and premolars for different segmentation methods were used as a measure to compare the results obtained. A new method of segmentation of overlapping dental arch components using digital records of illuminated plaster casts provides information with the precision required for orthodontic treatment. The distance between corresponding teeth was evaluated with a mean error of 1.38% and the Dice similarity coefficient of the evaluated dental bodies boundaries reached 0.9436 with a false positive rate [Formula: see text] and false negative rate [Formula: see text].

  1. Thermophysical properties of hydrophobised lime plaster - Experimental analysis of moisture effect

    NASA Astrophysics Data System (ADS)

    Pavlíková, Milena; Pernicová, Radka; Pavlík, Zbyšek

    2016-07-01

    Lime plasters are the most popular finishing materials in renewal of historical buildings and culture monuments. Because of their limited durability, new materials and design solutions are investigated in order to improve plasters performance in harmful environmental conditions. For the practical use, the plasters mechanical resistivity and the compatibility with substrate are the most decisive material parameters. However, also plasters hygric and thermal parameters affecting the overall hygrothermal function of the renovated structures are of the particular importance. On this account, the effect of moisture content on the thermophysical properties of a newly designed lime plasters containing hydrophobic admixture is analysed in the paper. For the comparative purposes, the reference lime and cement-lime plasters are tested as well. Basic characterization of the tested materials is done using bulk density, matrix density, and porosity measurements. Thermal conductivity and volumetric heat capacity in the broad range of moisture content are experimentally accessed using a transient impulse method. The obtained data reveals the significant increase of the both studied thermal parameters with increasing moisture content and gives information on plasters behaviour in a highly humid environment and/or in the case of their possible direct contact with liquid water. The accessed material parameters will be stored in a material database, where can find use as an input data for computational modelling of coupled heat and moisture transport in this type of porous building materials.

  2. AMS of an Analogue Non-Scale Model Simulating Diapiric Pluton Emplacement

    NASA Astrophysics Data System (ADS)

    Hrouda, F.; Kratinova, Z.; Zavada, P.; Schulmann, K.

    2004-12-01

    Development of magnetic fabric within a pluton during its diapiric ascent was investigated using an analogue non-scale model of plaster of Paris containing small amount of fine-grained (less than 0.09 mm) homogeneously mixed magnetite, with resulting bulk susceptibility being in the order of 10-3 [SI]. The apparatus for this modelling consists of a manual squeezer with calibrated spring and a perspex container. Stratified coloured to visualize internal flow geometries, weak plaster layer at the bottom of the container was forced to intrude overlying fine-grained (>0.017mm) sand through a hole in a board attached to the squeezer. A retarding compound was admixed into the plaster to postpone the solidification of plaster. After solidifying the model, small oriented cylindrical specimens (7 mm in diameter and 6 mm in height) were drilled and their anisotropy of magnetic susceptibility (AMS) was measured with the KLY-4S Kappabridge. The magnetic fabric in the margins of the vertical column of the diapir is characterized by high degree of AMS (P'=1.26-1.30), neutral to oblate AMS ellipsoid (T=0.2-0.6) and vertical magnetic lineations and foliations. In the vent area, the degree of AMS is also high, but the AMS ellipsoid being strongly prolate (T= -1 to -0.8) with vertical magnetic lineations. In the interior of the plug above the vent zone, abrupt transition into horizontal lineations and foliations take place and the low degree of AMS (P'=1.05-1.10) marks the area where strongly prolate magnetic fabric is being gradually changed into the magnetic fabric characterized by neutral to oblate AMS ellipsoid. This type of magnetic fabric extends to the apical part of the body. In the extrusive portions of the diapir, oblate magnetic fabric increases in anisotropy (T=0.8-1, P'=1.26-1.29), while the front of the radial extrusion shows horizontal lineations parallel to the margin and neutral AMS ellipsoids (T=0.2-0.6,P'=1.23-1.26). This changeover of fabric thus indicates divergent flow in the radial extrusion. The development of AMS fabric is correlated with complex flow pattern indicated by coloured and originally horizontal plaster layers. Narrow shear zones in the margins of the plug indicate non-linear behavior of plaster during experiments.

  3. Evaluation of gelatin hydrogel crosslinked with various crosslinking agents as bioadhesives: in vitro study.

    PubMed

    Sung, H W; Huang, D M; Chang, W H; Huang, R N; Hsu, J C

    1999-09-15

    Bioadhesives are used for tissue adhesion and hemostasis in surgery. A gelatin-resorcinol mixture crosslinked with formaldehyde (GRF glue) and/or glutaraldehyde (GRG) is used for this purpose. Although the bonding strength of the GRF glue to tissue is satisfactory, concerns about the cytotoxicity of formaldehyde are reported in the literature. It was suggested that the cytotoxicity problem of the GRF glue may be overcome by changing its crosslinking method. The study was therefore undertaken to assess the feasibility of using an epoxy compound (GRE glue), a water-soluble carbodiimide (GAC glue), or genipin (GG glue) to crosslink with a gelatin hydrogel as new bioadhesives. GRF glue and GRG glue were used as controls. The results of our cytotoxicity study suggested that the cellular compatibility of the GAC and GG glues was superior to the GRF, GRG, and GRE glues. The gelation time for the GG glue was relatively longer than the GRF and GRG glues, while no gelation time could be determined for the GAC glue. Additionally, it took approximately 17 h for the GRE glue to become adhesive. The GRF and GRG glues had the greatest bonding strengths to tissue among all test adhesives, while the bonding strengths of the GAC and GG glues were comparable. In contrast, there was almost no bonding strength to tissue for the GRE glue. However, the GRF and GRG glues were less flexible than the GAC and GG glues. Subsequent to the bonding strength measurement, each test adhesive was found to adhere firmly to the tissue surface and underwent cohesive failure during the bond breaking. In conclusion, the GRF and GRG glues may be used as tissue adhesives when their ability to bind tissue rapidly and tightly is required; the GAC and GG glues are preferable when the adhesive action must be accompanied with minimal cytotoxicity and stiffness; and the GRE glue is not suitable for bioadhesion in clinical applications. Copyright 1999 John Wiley & Sons, Inc.

  4. A Comparative Evaluation of Mixed Dentition Analysis on Reliability of Cone Beam Computed Tomography Image Compared to Plaster Model.

    PubMed

    Gowd, Snigdha; Shankar, T; Dash, Samarendra; Sahoo, Nivedita; Chatterjee, Suravi; Mohanty, Pritam

    2017-01-01

    The aim of the study was to evaluate the reliability of cone beam computed tomography (CBCT) obtained image over plaster model for the assessment of mixed dentition analysis. Thirty CBCT-derived images and thirty plaster models were derived from the dental archives, and Moyer's and Tanaka-Johnston analyses were performed. The data obtained were interpreted and analyzed statistically using SPSS 10.0/PC (SPSS Inc., Chicago, IL, USA). Descriptive and analytical analysis along with Student's t -test was performed to qualitatively evaluate the data and P < 0.05 was considered statistically significant. Statistically, significant results were obtained on data comparison between CBCT-derived images and plaster model; the mean for Moyer's analysis in the left and right lower arch for CBCT and plaster model was 21.2 mm, 21.1 mm and 22.5 mm, 22.5 mm, respectively. CBCT-derived images were less reliable as compared to data obtained directly from plaster model for mixed dentition analysis.

  5. Spectroscopic, microchemical and petrographic analyses of plasters from ancient buildings in Lamezia Terme (Calabria, Southern Italy)

    NASA Astrophysics Data System (ADS)

    De Luca, Raffaella; Gigliotti, Valentina; Panarello, Mario; Bloise, Andrea; Crisci, Gino M.; Miriello, Domenico

    2016-01-01

    This work shows the results of the spectroscopic, microchemical and petrographic study carried out on six plasters coming from three important residential buildings of the 18th century, located in Lamezia Terme (Catanzaro, Southern Italy). To study the provenance of the raw materials used to make the plasters, one sample of limestone and two samples of sand were also collected from the quarries near Lamezia Terme and compared with the historical plasters. Samples were studied by polarized optical microscopy (OM), X-ray powder diffraction (XRPD), scanning electron microscopy (SEM) with energy dispersive X-ray spectroscopy (EDS) and Raman spectroscopy. The results of these analyses allowed to determine the mineralogical, petrographical and chemical characteristics of the plasters, identify the pigments used for their coloration and provide useful information about the building techniques, the raw materials employed and the production technology of plasters during the 18th century in Lamezia Terme. SEM-EDS microanalysis also revealed the presence of gold and silver on the surface of two samples.

  6. Accuracy of laser-scanned models compared to plaster models and cone-beam computed tomography.

    PubMed

    Kim, Jooseong; Heo, Giseon; Lagravère, Manuel O

    2014-05-01

    To compare the accuracy of measurements obtained from the three-dimensional (3D) laser scans to those taken from the cone-beam computed tomography (CBCT) scans and those obtained from plaster models. Eighteen different measurements, encompassing mesiodistal width of teeth and both maxillary and mandibular arch length and width, were selected using various landmarks. CBCT scans and plaster models were prepared from 60 patients. Plaster models were scanned using the Ortho Insight 3D laser scanner, and the selected landmarks were measured using its software. CBCT scans were imported and analyzed using the Avizo software, and the 26 landmarks corresponding to the selected measurements were located and recorded. The plaster models were also measured using a digital caliper. Descriptive statistics and intraclass correlation coefficient (ICC) were used to analyze the data. The ICC result showed that the values obtained by the three different methods were highly correlated in all measurements, all having correlations>0.808. When checking the differences between values and methods, the largest mean difference found was 0.59 mm±0.38 mm. In conclusion, plaster models, CBCT models, and laser-scanned models are three different diagnostic records, each with its own advantages and disadvantages. The present results showed that the laser-scanned models are highly accurate to plaster models and CBCT scans. This gives general clinicians an alternative to take into consideration the advantages of laser-scanned models over plaster models and CBCT reconstructions.

  7. Effect of Fibrin Glue on the Biomechanical Properties of Human Descemet's Membrane

    PubMed Central

    Chaurasia, Shyam S.; Champakalakshmi, Ravi; Li, Ang; Poh, Rebekah; Tan, Xiao Wei; Lakshminarayanan, Rajamani; Lim, Chwee T.; Tan, Donald T.; Mehta, Jodhbir S.

    2012-01-01

    Background Corneal transplantation has rapidly evolved from full-thickness penetrating keratoplasty (PK) to selective tissue corneal transplantation, where only the diseased portions of the patient's corneal tissue are replaced with healthy donor tissue. Descemet's membrane endothelial keratoplasty (DMEK) performed in patients with corneal endothelial dysfunction is one such example where only a single layer of endothelial cells with its basement membrane (10–15 µm in thickness), Descemet's membrane (DM) is replaced. It is challenging to replace this membrane due to its intrinsic property to roll in an aqueous environment. The main objective of this study was to determine the effects of fibrin glue (FG) on the biomechanical properties of DM using atomic force microscopy (AFM) and relates these properties to membrane folding propensity. Methodology/Principal Findings Fibrin glue was sprayed using the EasySpray applicator system, and the biomechanical properties of human DM were determined by AFM. We studied the changes in the “rolling up” tendency of DM by examining the changes in the elasticity and flexural rigidity after the application of FG. Surface topography was assessed using scanning electron microscopy (SEM) and AFM imaging. Treatment with FG not only stabilized and stiffened DM but also led to a significant increase in hysteresis of the glue-treated membrane. In addition, flexural or bending rigidity values also increased in FG-treated membranes. Conclusions/Significance Our results suggest that fibrin glue provides rigidity to the DM/endothelial cell complex that may aid in subsequent manipulation by maintaining tissue integrity. PMID:22662156

  8. Interior building details of Building A, Room A002: plastered painted ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Interior building details of Building A, Room A-002: plastered painted west brick wall, four light double-hung wood window with brick arch lintel, east plastered wall (could be granite), wood ceiling; northerly view - San Quentin State Prison, Building 22, Point San Quentin, San Quentin, Marin County, CA

  9. Ternary binder based plasters with improved thermal insulating ability

    NASA Astrophysics Data System (ADS)

    Čáchová, M.; Koňáková, D.; Vejmelková, E.; Vyšvařil, M.

    2017-10-01

    New kind of plasters with improved thermal insulating ability are presented in this article. Improvement was reached by utilization of lightweight expanded perlite with high porosity. The second used aggregate was silica sand. Regarding the binder, three kind were combined for the reason of better plaster performance. Pure lime, Portland cement and pozzolanic ceramic powder were employed. Basic physical properties and thermal characteristics were determined. The porosity of plasters reached desired higher value about 50% and the thermal conductivity in dry state was lower than 0.16 Wm-1K-1.

  10. Mortality among unionized construction plasterers and cement masons.

    PubMed

    Stern, F; Lehman, E; Ruder, A

    2001-04-01

    Plasterers perform a variety of duties including interior and exterior plastering of drywall, cement, stucco, and stone imitation; the preparation, installation, and repair of all interior and exterior insulation systems; and the fireproofing of steel beams and columns. Some of the current potential toxic exposures among plasterers include plaster of Paris, silica, fiberglass, talc, and 1,1,1-trichloroethylene; asbestos had been used by the plasterers in the past. Cement masons, on the other hand, are involved in concrete construction of buildings, bridges, curbs and gutters, sidewalks, highways, streets and roads, floors and pavements and the finishing of same, when necessary, by sandblasting or any other method. Exposures include cement dust, silica, asphalt, and various solvents. Proportionate mortality ratios (PMRs) and proportionate cancer mortality ratios (PCMRs) were calculated for 99 causes of death among 12,873 members of the Operative Plasterers' and Cement Masons' International Association who died between 1972 and 1996 using United States age-, race-, and calender-specific death rates. Statistical significance (P value) of results was based upon the Poisson distribution. Among plasterers, statistically significant elevated mortality was observed for asbestosis, where the PMR reached 1,657 (P < 0.01) with eleven observed deaths and less than one death expected, for lung cancer (PCMR = 124, P < 0.01), and for benign neoplasms (PMR = 210, P < 0.05). Among cement masons, statistically significant elevated mortality was observed for cancer of the stomach (PCMR = 133, P < 0.01), benign neoplasms (PMR = 132, P < 0.01), and poisonings (PMR = 159, P < 0.05). Except for poisonings, which were not thought to be occupationally related, all of the statistically significant results occurred among those members who entered the union prior to 1950. However, the risk for lung cancer among plasterers was still elevated among those entering the union after 1970 as was the risk for stomach cancer among cement masons who entered the union after 1950. The present study suggests that plasterers and cement masons still have elevated risks for certain diseases, especially lung and stomach cancer. Therefore, union members currently living should be screened for asbestos-related diseases and educated about the future risks for these diseases.

  11. Clay Portrait Boxes

    ERIC Educational Resources Information Center

    Wilbert, Nancy Corrigan

    2009-01-01

    In an attempt to incorporate sculptural elements into her ceramics program, the author decided to try direct plaster casting of the face to make a plaster mold for clay. In this article, the author shares an innovative ceramics lesson that teaches students in making plaster casts and casting the face in clay. This project gives students the…

  12. Thermophysical properties of hydrophobised lime plasters - The influence of ageing

    NASA Astrophysics Data System (ADS)

    Pavlíková, Milena; Zemanová, Lucie; Pavlík, Zbyšek

    2017-07-01

    The building envelope is a principal responsible for buildings energy loses. Lime plasters as the most popular finishing materials of historical buildings and culture monuments influence the thermal behaviour as well as construction material of masonry. On this account, the effect of ageing on the thermophysical properties of a newly designed lime plasters containing hydrophobic admixture is analysed in the paper. For the comparative purposes, the reference lime plaster is tested. The ageing is accelerated with controlled carbonation process to simulate the final plasters properties. Basic characterization of the tested materials is done using bulk density, matrix density, and porosity measurements. Thermal conductivity and volumetric heat capacity are experimentally assessed using a transient impulse method. The obtained data revealed the significant changes of the both studied thermal parameters in the dependence on plasters composition and age. The assessed material parameters will be stored in a material database, where will find use as an input data for computational modelling of heat transport in this type of porous building materials and evaluation of energy-savings and sustainability issues.

  13. A Comparative Evaluation of Mixed Dentition Analysis on Reliability of Cone Beam Computed Tomography Image Compared to Plaster Model

    PubMed Central

    Gowd, Snigdha; Shankar, T; Dash, Samarendra; Sahoo, Nivedita; Chatterjee, Suravi; Mohanty, Pritam

    2017-01-01

    Aims and Objective: The aim of the study was to evaluate the reliability of cone beam computed tomography (CBCT) obtained image over plaster model for the assessment of mixed dentition analysis. Materials and Methods: Thirty CBCT-derived images and thirty plaster models were derived from the dental archives, and Moyer's and Tanaka-Johnston analyses were performed. The data obtained were interpreted and analyzed statistically using SPSS 10.0/PC (SPSS Inc., Chicago, IL, USA). Descriptive and analytical analysis along with Student's t-test was performed to qualitatively evaluate the data and P < 0.05 was considered statistically significant. Results: Statistically, significant results were obtained on data comparison between CBCT-derived images and plaster model; the mean for Moyer's analysis in the left and right lower arch for CBCT and plaster model was 21.2 mm, 21.1 mm and 22.5 mm, 22.5 mm, respectively. Conclusion: CBCT-derived images were less reliable as compared to data obtained directly from plaster model for mixed dentition analysis. PMID:28852639

  14. Synthesis of Plaster for moulers's elaboration of imprint denture

    NASA Astrophysics Data System (ADS)

    Hamiane, M.; Rabahi, N.; Saidi, M.; Salhi, M.

    2012-02-01

    Our goal was the synthesis of plaster from local raw materials to be used in denture mouler's. The plaster type α and β was synthesis by hydrothermal and dry method from gypsum (CaSO4. 2H2O) of the west Algerian. After crushing and mineralogical analysis, gypsum has undergone through cooking in an oven at a temperature (T = 200 ° C), for a time t = 4 hours. The synthesis and characterization of the product has involved several ways investigated as diffraction RX, X-ray fluorescence, time taken, electron microscope (MEB), hardness, SSB, compressive and bending strength and Ph. A digester horizontal type Toni - technical laboratory was used for the synthesis of plasterα. The results are conformable with the standard and plaster synthesized can be a basic material in the manufacture of moulers imprint denture.

  15. Caged Molecular Glues as Photoactivatable Tags for Nuclear Translocation of Guests in Living Cells.

    PubMed

    Arisaka, Akio; Mogaki, Rina; Okuro, Kou; Aida, Takuzo

    2018-02-21

    We developed dendritic caged molecular glues ( Caged Glue-R) as tags for nucleus-targeted drug delivery, whose multiple guanidinium ion (Gu + ) pendants are protected by an anionic photocleavable unit (butyrate-substituted nitroveratryloxycarbonyl; BA NVOC). Negatively charged Caged Glue-R hardly binds to anionic biomolecules because of their electrostatic repulsion. However, upon exposure of Caged Glue-R to UV light or near-infrared (NIR) light, the BA NVOC groups of Caged Glue-R are rapidly detached to yield an uncaged molecular glue ( Uncaged Glue-R) that carries multiple Gu + pendants. Because Gu + forms a salt bridge with PO 4 - , Uncaged Glue-R tightly adheres to anionic biomolecules such as DNA and phospholipids in cell membranes by a multivalent salt-bridge formation. When tagged with Caged Glue-R, guests can be taken up into living cells via endocytosis and hide in endosomes. However, when the Caged Glue-R tag is photochemically uncaged to form Uncaged Glue-R, the guests escape from the endosome and migrate into the cytoplasm followed by the cell nucleus. We demonstrated that quantum dots (QDs) tagged with Caged Glue-R can be delivered efficiently to cell nuclei eventually by irradiation with light.

  16. Efficacy of betamethasone valerate medicated plaster on painful chronic elbow tendinopathy: a double-blind, randomized, placebo-controlled trial

    PubMed Central

    Frizziero, Antonio; Causero, Araldo; Bernasconi, Stefano; Papalia, Rocco; Longo, Mario; Sessa, Vincenzo; Sadile, Francesco; Greco, Pasquale; Tarantino, Umberto; Masiero, Stefano; Rovati, Stefano; Frangione, Valeria

    2016-01-01

    Summary Objective to investigate the efficacy and safety of a medicated plaster containing betamethasone valerate (BMV) 2.25 mg in patients with chronic elbow tendinopathy. Methods randomized, double-blind, placebo-controlled study with assignment 2:2:1:1 to BMV medicated plaster applied daily for 12 hours, daily for 24 hours or matched placebo. 62 patients aged ≥18 years with chronic lateral elbow tendinopathy were randomized. The primary efficacy variable was pain reduction (VAS) at day 28. Secondary objectives included summed pain intensity differences (SPID), overall treatment efficacy and tolerability. Results mean reduction in VAS pain score at day 28 was greater in both BMV medicated plaster groups, −39.35±27.69 mm for BMV12-h and −36.91±32.50 mm for BMV24-h, than with placebo, −20.20±27.32 mm. Considering the adjusted mean decreases, there was a statistically significant difference between BMV12-h and placebo (p=0.0110). Global pain relief (SPID) and overall treatment efficacy were significantly better with BMV. BMV and placebo plasters had similar local tolerability and there were few treatment-related adverse events. Conclusions BMV plaster was significantly more effective than placebo at reducing pain in patients with chronic elbow tendinopathies. The BMV plaster was safe and well tolerated. PMID:27331041

  17. 3-D Wizardry: Design in Papier-Mache, Plaster, and Foam.

    ERIC Educational Resources Information Center

    Wolfe, George

    Papier-mache, plaster, and foam are inexpensive and versatile media for 3-dimensional classroom and studio art experiences. They can be used equally well by elementary, high school, or college students. Each medium has its own characteristic. Papier-mache is pliable but dries into a hard, firm surface that can be waterproofed. Plaster can be…

  18. Populations of some molds in water-damaged homes may differ if the home was constructed with gypsum drywall compared to plaster

    EPA Science Inventory

    Starting in the 1940s, gypsum drywall began replacing plaster and lathe in the U.S. home construction industry. Our goal was to evaluate whether some mold populations differ in water- damaged homes primarily constructed with gypsum drywall compared to plaster. The dust samples fr...

  19. A Novel Ecdysone Receptor Mediates Steroid-Regulated Developmental Events during the Mid-Third Instar of Drosophila

    PubMed Central

    Costantino, Benjamin F. B.; Bricker, Daniel K.; Alexandre, Kelly; Shen, Kate; Merriam, John R.; Antoniewski, Christophe; Callender, Jenna L.; Henrich, Vincent C.; Presente, Asaf; Andres, Andrew J.

    2008-01-01

    The larval salivary gland of Drosophila melanogaster synthesizes and secretes glue glycoproteins that cement developing animals to a solid surface during metamorphosis. The steroid hormone 20-hydroxyecdysone (20E) is an essential signaling molecule that modulates most of the physiological functions of the larval gland. At the end of larval development, it is known that 20E—signaling through a nuclear receptor heterodimer consisting of EcR and USP—induces the early and late puffing cascade of the polytene chromosomes and causes the exocytosis of stored glue granules into the lumen of the gland. It has also been reported that an earlier pulse of hormone induces the temporally and spatially specific transcriptional activation of the glue genes; however, the receptor responsible for triggering this response has not been characterized. Here we show that the coordinated expression of the glue genes midway through the third instar is mediated by 20E acting to induce genes of the Broad Complex (BRC) through a receptor that is not an EcR/USP heterodimer. This result is novel because it demonstrates for the first time that at least some 20E-mediated, mid-larval, developmental responses are controlled by an uncharacterized receptor that does not contain an RXR-like component. PMID:18566664

  20. Royal London space analysis: plaster versus digital model assessment.

    PubMed

    Grewal, Balpreet; Lee, Robert T; Zou, Lifong; Johal, Ama

    2017-06-01

    With the advent of digital study models, the importance of being able to evaluate space requirements becomes valuable to treatment planning and the justification for any required extraction pattern. This study was undertaken to compare the validity and reliability of the Royal London space analysis (RLSA) undertaken on plaster as compared with digital models. A pilot study (n = 5) was undertaken on plaster and digital models to evaluate the feasibility of digital space planning. This also helped to determine the sample size calculation and as a result, 30 sets of study models with specified inclusion criteria were selected. All five components of the RLSA, namely: crowding; depth of occlusal curve; arch expansion/contraction; incisor antero-posterior advancement and inclination (assessed from the pre-treatment lateral cephalogram) were accounted for in relation to both model types. The plaster models served as the gold standard. Intra-operator measurement error (reliability) was evaluated along with a direct comparison of the measured digital values (validity) with the plaster models. The measurement error or coefficient of repeatability was comparable for plaster and digital space analyses and ranged from 0.66 to 0.95mm. No difference was found between the space analysis performed in either the upper or lower dental arch. Hence, the null hypothesis was accepted. The digital model measurements were consistently larger, albeit by a relatively small amount, than the plaster models (0.35mm upper arch and 0.32mm lower arch). No difference was detected in the RLSA when performed using either plaster or digital models. Thus, digital space analysis provides a valid and reproducible alternative method in the new era of digital records. © The Author 2016. Published by Oxford University Press on behalf of the European Orthodontic Society. All rights reserved. For permissions, please email: journals.permissions@oup.com

  1. Fungal-Induced Deterioration of Mural Paintings: In Situ and Mock-Model Microscopy Analyses.

    PubMed

    Unković, Nikola; Grbić, Milica Ljaljević; Stupar, Miloš; Savković, Željko; Jelikić, Aleksa; Stanojević, Dragan; Vukojević, Jelena

    2016-04-01

    Fungal deterioration of frescoes was studied in situ on a selected Serbian church, and on a laboratory model, utilizing standard and newly implemented microscopy techniques. Scanning electron microscopy (SEM) with energy-dispersive X-ray confirmed the limestone components of the plaster. Pigments used were identified as carbon black, green earth, iron oxide, ocher, and an ocher/cinnabar mixture. In situ microscopy, applied via a portable microscope ShuttlePix P-400R, proved very useful for detection of invisible micro-impairments and hidden, symptomless, microbial growth. SEM and optical microscopy established that observed deterioration symptoms, predominantly discoloration and pulverization of painted layers, were due to bacterial filaments and fungal hyphal penetration, and formation of a wide range of fungal structures (i.e., melanized hyphae, chlamydospores, microcolonial clusters, Cladosporium-like conidia, and Chaetomium perithecia and ascospores). The all year-round monitoring of spontaneous and induced fungal colonization of a "mock painting" in controlled laboratory conditions confirmed the decisive role of humidity level (70.18±6.91% RH) in efficient colonization of painted surfaces, as well as demonstrated increased bioreceptivity of painted surfaces to fungal colonization when plant-based adhesives (ilinocopie, murdent), compared with organic adhesives of animal origin (bone glue, egg white), are used for pigment sizing.

  2. Adhesive plasters

    DOEpatents

    Holcombe, Jr., Cressie E.; Swain, Ronald L.; Banker, John G.; Edwards, Charlene C.

    1978-01-01

    Adhesive plaster compositions are provided by treating particles of Y.sub.2 O.sub.3, Eu.sub.2 O.sub.3, Gd.sub.2 O.sub.3 or Nd.sub.2 O.sub.3 with dilute acid solutions. The resulting compositions have been found to spontaneously harden into rigid reticulated masses resembling plaster of Paris. Upon heating, the hardened material is decomposed into the oxide, yet retains the reticulated rigid structure.

  3. Exterior building details of Building A; east façade: concrete staircase, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Exterior building details of Building A; east façade: concrete staircase, profiled cement, plaster door surround, recessed panel inscribed "1859", historic window opening with concrete sill above door, cement plaster dentil course and cornice truncated wood beam ends, plaster finished brick wall, granite base; westerly view - San Quentin State Prison, Building 22, Point San Quentin, San Quentin, Marin County, CA

  4. 21 CFR 178.3120 - Animal glue.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 3 2014-04-01 2014-04-01 false Animal glue. 178.3120 Section 178.3120 Food and... Animal glue. Animal glue may be safely used as a component of articles intended for use in producing... the provisions of this section. (a) Animal glue consists of the proteinaceous extractives obtained...

  5. Serum aluminium levels in glue-sniffer adolescent and in glue containers.

    PubMed

    Akay, Cemal; Kalman, Süleyman; Dündaröz, Ruşen; Sayal, Ahmet; Aydin, Ahmet; Ozkan, Yalçin; Gül, Hüsamettin

    2008-05-01

    Glue sniffing is a serious medical problem among teenagers. Various chemical substances such as toluene and benzene containing glues have been reported to be toxic. It has been demonstrated that some toxic metals such as lead are elevated in the blood of solvent-addicted patients. Whereas aluminium is an element that has toxic effects on neurological, hematopoetic system and bone metabolism. We want to determine the serum levels of aluminium in glue-sniffer adolescents in comparison with healthy subjects. In addition, we compared aluminium levels of different commercial glue preparations (i.e. metal and plastic containers), to determine which type of container is better for less aluminium toxicity. We measured serum levels of aluminium in 37 glue-sniffer and 37 healthy subjects using atomic absorption spectrophotometry. The average duration of glue-sniffer was 3.8 +/- 0.8 years. We also measured aluminium levels of 10 commercial glue preparations that seven of them with metal and three with plastic containers. We found that serum levels of aluminium were 63.29 +/- 13.20 ng/ml and 36.7 +/- 8.60 ng/ml in glue-sniffer and in control subjects, respectively (P < 0.001). The average aluminium level in the glues was 8.6 +/- 3.24 ng/g in the preparations with metal containers, whereas 3.03 +/- 0.76 ng/g with plastic containers (P < 0.001). Therefore, to decrease the incidence of aluminium toxicity in glue-sniffers, it may be a good step to market of glue preparations in plastic instead of metal containers.

  6. Digital model as an alternative to plaster model in assessment of space analysis

    PubMed Central

    Kumar, A. Anand; Phillip, Abraham; Kumar, Sathesh; Rawat, Anuradha; Priya, Sakthi; Kumaran, V.

    2015-01-01

    Introduction: Digital three-dimensional models are widely used for orthodontic diagnosis. The purpose of this study was to appraise the accuracy of digital models obtained from computer-aided design/computer-aided manufacturing (CAD/CAM) and cone-beam computed tomography (CBCT) for tooth-width measurements and the Bolton analysis. Materials and Methods: Digital models (CAD/CAM, CBCT) and plaster model were made for each of 50 subjects. Tooth-width measurements on the digital models (CAD/CAM, CBCT) were compared with those on the corresponding plaster models. The anterior and overall Bolton ratios were calculated for each participant and for each method. The paired t-test was applied to determine the validity. Results: Tooth-width measurements, anterior, and overall Bolton ratio of digital models of CAD/CAM and CBCT did not differ significantly from those on the plaster models. Conclusion: Hence, both CBCT and CAD/CAM are trustable and promising technique that can replace plaster models due to its overwhelming advantages. PMID:26538899

  7. 21 CFR 178.3120 - Animal glue.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 3 2011-04-01 2011-04-01 false Animal glue. 178.3120 Section 178.3120 Food and... and Production Aids § 178.3120 Animal glue. Animal glue may be safely used as a component of articles..., transporting, or holding food, subject to the provisions of this section. (a) Animal glue consists of the...

  8. 21 CFR 178.3120 - Animal glue.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 3 2010-04-01 2009-04-01 true Animal glue. 178.3120 Section 178.3120 Food and... and Production Aids § 178.3120 Animal glue. Animal glue may be safely used as a component of articles..., transporting, or holding food, subject to the provisions of this section. (a) Animal glue consists of the...

  9. 21 CFR 178.3120 - Animal glue.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 3 2012-04-01 2012-04-01 false Animal glue. 178.3120 Section 178.3120 Food and... and Production Aids § 178.3120 Animal glue. Animal glue may be safely used as a component of articles..., transporting, or holding food, subject to the provisions of this section. (a) Animal glue consists of the...

  10. 21 CFR 178.3120 - Animal glue.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 3 2013-04-01 2013-04-01 false Animal glue. 178.3120 Section 178.3120 Food and... and Production Aids § 178.3120 Animal glue. Animal glue may be safely used as a component of articles..., transporting, or holding food, subject to the provisions of this section. (a) Animal glue consists of the...

  11. Can treatment success with 5% lidocaine medicated plaster be predicted in cancer pain with neuropathic components or trigeminal neuropathic pain?

    PubMed Central

    Kern, Kai-Uwe; Nalamachu, Srinivas; Brasseur, Louis; Zakrzewska, Joanna M

    2013-01-01

    An expert group of 40 pain specialists from 16 countries performed a first assessment of the value of predictors for treatment success with 5% lidocaine-medicated plaster in the management of cancer pain with neuropathic components and trigeminal neuropathic pain. Results were based on the retrospective analysis of 68 case reports (sent in by participants in the 4 weeks prior to the conference) and the practical experience of the experts. Lidocaine plaster treatment was mostly successful for surgery or chemotherapy-related cancer pain with neuropathic components. A dose reduction of systemic pain treatment was observed in at least 50% of all cancer pain patients using the plaster as adjunct treatment; the presence of allodynia, hyperalgesia or pain quality provided a potential but not definitively clear indication of treatment success. In trigeminal neuropathic pain, continuous pain, severe allodynia, hyperalgesia, or postherpetic neuralgia or trauma as the cause of orofacial neuropathic pain were perceived as potential predictors of treatment success with lidocaine plaster. In conclusion, these findings provide a first assessment of the likelihood of treatment benefits with 5% lidocaine-medicated plaster in the management of cancer pain with neuropathic components and trigeminal neuropathic pain and support conducting large, well-designed multicenter studies. PMID:23630431

  12. A numerical study of defect detection in a plaster dome ceiling using structural acoustics.

    PubMed

    Bucaro, J A; Romano, A J; Valdivia, N; Houston, B H; Dey, S

    2009-07-01

    A numerical study is carried out to evaluate the effectiveness of using measured surface displacements resulting from acoustic speaker excitation to detect and localize flaws in a domed, plaster ceiling. The response of the structure to an incident acoustic pressure is obtained at four frequencies between 100 and 400 Hz using a parallel h-p structural acoustic finite element-based code. Three ceiling conditions are modeled: the pristine ceiling considered rigidly attached to the domed-shape support, partial detachment of a segment of the plaster layer from the support, and an interior pocket of plaster deconsolidation modeled as a heavy fluid. Spatial maps of the normal displacement resulting from speaker excitation are interpreted with the help of predictions based on static analysis. It is found that acoustic speaker excitation can provide displacement levels readily detected by commercially available laser Doppler vibrometer systems. Further, it is concluded that for 1 in. thick plaster layers, detachment sizes as small as 4 cm are detectable by direct observation of the measured displacement maps. Finally, spatial structure differences are observed in the displacement maps beneath the two defect types, which may provide a wavenumber-based feature useful for distinguishing plaster detachment from other defects such as deconsolidation.

  13. Comparison of linear measurements and analyses taken from plaster models and three-dimensional images.

    PubMed

    Porto, Betina Grehs; Porto, Thiago Soares; Silva, Monica Barros; Grehs, Renésio Armindo; Pinto, Ary dos Santos; Bhandi, Shilpa H; Tonetto, Mateus Rodrigues; Bandéca, Matheus Coelho; dos Santos-Pinto, Lourdes Aparecida Martins

    2014-11-01

    Digital models are an alternative for carrying out analyses and devising treatment plans in orthodontics. The objective of this study was to evaluate the accuracy and the reproducibility of measurements of tooth sizes, interdental distances and analyses of occlusion using plaster models and their digital images. Thirty pairs of plaster models were chosen at random, and the digital images of each plaster model were obtained using a laser scanner (3Shape R-700, 3Shape A/S). With the plaster models, the measurements were taken using a caliper (Mitutoyo Digimatic(®), Mitutoyo (UK) Ltd) and the MicroScribe (MS) 3DX (Immersion, San Jose, Calif). For the digital images, the measurement tools used were those from the O3d software (Widialabs, Brazil). The data obtained were compared statistically using the Dahlberg formula, analysis of variance and the Tukey test (p < 0.05). The majority of the measurements, obtained using the caliper and O3d were identical, and both were significantly different from those obtained using the MS. Intra-examiner agreement was lowest when using the MS. The results demonstrated that the accuracy and reproducibility of the tooth measurements and analyses from the plaster models using the caliper and from the digital models using O3d software were identical.

  14. Efficacy and Safety of Calcipotriol Plus Betamethasone Dipropionate Aerosol Foam Compared with Betamethasone 17-Valerate-Medicated Plaster for the Treatment of Psoriasis.

    PubMed

    Queille-Roussel, Catherine; Rosen, Monika; Clonier, Fabrice; Nørremark, Kasper; Lacour, Jean-Philippe

    2017-04-01

    Fixed combination calcipotriol as hydrate (Cal) 50 µg/g plus betamethasone as dipropionate (BD) 0.5 mg/g aerosol foam is an alcohol-free treatment for psoriasis. Betamethasone 17-valerate 2.25 mg (BV)-medicated plasters are recommended for treating psoriasis plaques localized in difficult-to-treat (DTT; elbow, knee, anterior face of the tibia) areas. The aim of this study was to compare the efficacy of Cal/BD foam with BV-medicated plaster in patients with plaque psoriasis. In this phase IIa, randomized, single-center, investigator-blinded, 4-week study, both Cal/BD foam and BV-medicated plaster were applied once daily to six test sites (three for each treatment). The primary efficacy endpoint was absolute change in total clinical score (TCS; sum of erythema, scaling, and infiltration); secondary endpoints were changes from baseline in each individual clinical score, ultrasonographic changes (total skin and echo-poor band thickness), and safety; and post hoc analysis was change from baseline in TCS on DTT areas. Thirty-five patients were included. Least-squares mean change in TCS from baseline was significantly greater for Cal/BD foam (-5.8) than BV-medicated plaster (-3.7; difference -2.2; 95% confidence interval -2.6 to -1.8; p < 0.001); greater changes for Cal/BD foam were observed from day 8 for each clinical sign. Absolute total skin and echo-poor band thickness change was significantly greater for Cal/BD foam than for BV-medicated plaster (both p < 0.001). Post hoc analyses showed that Cal/BD foam was significantly more effective than BV-medicated plaster on DTT areas after 4 weeks (p < 0.001), and both treatments were well tolerated. Cal/BD foam demonstrated superior efficacy versus BV-medicated plasters, including on DTT areas, in patients with plaque psoriasis. NCT02518048.

  15. Mechanical and chemical characteristics of an autologous glue.

    PubMed

    De Somer, Filip; Delanghe, Joris; Somers, Pamela; Debrouwere, Maarten; Van Nooten, Guido

    2008-09-15

    The study evaluates the mechanical and chemical characteristics of autologous surgical glue made by mixing ultrafiltered plasma with glutaraldehyde (GTA). Human albumin 200 g/L mixed with different concentrations of GTA (25, 50, 75, or 100 g/L) was used as a single protein set-up for testing tensile strength, elasticity, and rate of crosslinking. Subsequently, ultrafiltered canine or human plasma to obtain autologous glue replaced human albumin. BioGlue, a surgical glue, and Tissucol Duo, a fibrin sealant, were used as controls. Tensile strength of human albumin 200 g/L mixed with 75 g/L GTA is 825 +/- 109 N versus 672 +/- 167 N for BioGlue. Ultrafiltered canine plasma showed a maximum tensile strength of 634 +/- 137 N when mixed with GTA 75 g/L. For human plasma, the maximum tensile strength of 436 +/- 69 N was reached after mixing with GTA 25 g/L. Autologous glue had a higher elasticity of 144 +/- 66 N versus 322 +/- 104 N for BioGlue at maximum load. Autologous glues for vascular repair can be easily prepared out of the patient's plasma. The optimal characteristics, compared to BioGlue, are obtained for ultrafiltered canine and human plasma by mixing with a GTA concentration of 50-75 g/L and 25-50 g/L, respectively. The autologous glue will exert less tensile strength than BioGlue but has a better compliance. In case where no plasma can obtained from the patient, mixing human albumin 200 g/L with GTA 75 g/L can be an alternative to BioGlue.

  16. Fibrin Glue Improves the Therapeutic Effect of MSCs by Sustaining Survival and Paracrine Function

    PubMed Central

    Kim, Inok; Lee, Sung Koo; Yoon, Jung In; Kim, Da Eun

    2013-01-01

    Fibrin glue has been widely investigated as a cell delivery vehicle for improving the therapeutic effects of mesenchymal stem cells (MSCs). Implanted MSCs produce their therapeutic effects by secreting paracrine factors and by replacing damaged tissues after differentiation. While the influence of fibrin glue on the differentiation potential of MSCs has been well documented, its effect on paracrine function of MSCs is largely unknown. Herein we investigated the influence of fibrin glue on the paracrine effects of MSCs. MSCs were isolated from human adipose tissue. The effects of fibrin glue on survival, migration, secretion of growth factors, and immune suppression of MSCs were investigated in vitro. MSCs in fibrin glue survived and secreted growth factors such as the vascular endothelial growth factor (VEGF) and hepatocyte growth factor (HGF) over 14 days. VEGF and immune modulators, including the transforming growth factor (TGF)-β1 and prostaglandin E2, secreted from MSCs in fibrin glue significantly increased under inflammatory conditions. Thus, MSCs in fibrin glue effectively suppressed immune reactions. In addition, fibrin glue protected the MSCs from oxidative stress and prevented human dermal fibroblast death induced by exposure to extreme stress. In contrast, MSCs within fibrin glue hardly migrated. These results suggest that fibrin glue may sustain survival of implanted MSCs and their paracrine function. Our results provide a mechanistic data to allow further development of MSCs with fibrin glue as a clinical treatment. PMID:23701237

  17. Seals, Concrete Anchors, and Connections

    DTIC Science & Technology

    1989-02-01

    brick. Medium to heavy I.. loads cannot be safely fastened to soft masonry materials (stuc-. : - . co. grout. plaster or plasterboard ) since such...588C, Type 1. Class A. Style 1 Use in: All masonry material Use in: Block, wallboard , plaster , hollow tile Use with: Sheet metal, wood or lag screws... Wallboard . plaster , paneling Use in: Wallboard or solid masonry Use with: No (- oer fastener needed Use with: Sheet metal screw Made of: Ste( Made of

  18. Adhesive plasters. [Patent application; coatings for crucibles, control rods, etc

    DOEpatents

    Holcombe, C.E. Jr.; Swain, R.L.; Banker, J.G.; Edwards, C.C.

    1975-09-26

    Adhesive plaster compositions are provided by treating particles of Y/sub 2/O/sub 3/, Eu/sub 2/O/sub 3/, Gd/sub 2/O/sub 3/, or Nd/sub 2/O/sub 3/ with dilute acid solutions. The resulting compositions were found to harden spontaneously into rigid reticulated masses resembling plaster of Paris. Upon heating, the hardened material is decomposed into the oxide, yet retains the reticulated rigid structure. 1 table.

  19. Compounds from silicones alter enzyme activity in curing barnacle glue and model enzymes.

    PubMed

    Rittschof, Daniel; Orihuela, Beatriz; Harder, Tilmann; Stafslien, Shane; Chisholm, Bret; Dickinson, Gary H

    2011-02-17

    Attachment strength of fouling organisms on silicone coatings is low. We hypothesized that low attachment strength on silicones is, in part, due to the interaction of surface available components with natural glues. Components could alter curing of glues through bulk changes or specifically through altered enzyme activity. GC-MS analysis of silicone coatings showed surface-available siloxanes when the coatings were gently rubbed with a cotton swab for 15 seconds or given a 30 second rinse with methanol. Mixtures of compounds were found on 2 commercial and 8 model silicone coatings. The hypothesis that silicone components alter glue curing enzymes was tested with curing barnacle glue and with commercial enzymes. In our model, barnacle glue curing involves trypsin-like serine protease(s), which activate enzymes and structural proteins, and a transglutaminase which cross-links glue proteins. Transglutaminase activity was significantly altered upon exposure of curing glue from individual barnacles to silicone eluates. Activity of purified trypsin and, to a greater extent, transglutaminase was significantly altered by relevant concentrations of silicone polymer constituents. Surface-associated silicone compounds can disrupt glue curing and alter enzyme properties. Altered curing of natural glues has potential in fouling management.

  20. Compounds from Silicones Alter Enzyme Activity in Curing Barnacle Glue and Model Enzymes

    PubMed Central

    Rittschof, Daniel; Orihuela, Beatriz; Harder, Tilmann; Stafslien, Shane; Chisholm, Bret; Dickinson, Gary H.

    2011-01-01

    Background Attachment strength of fouling organisms on silicone coatings is low. We hypothesized that low attachment strength on silicones is, in part, due to the interaction of surface available components with natural glues. Components could alter curing of glues through bulk changes or specifically through altered enzyme activity. Methodology/Principal Findings GC-MS analysis of silicone coatings showed surface-available siloxanes when the coatings were gently rubbed with a cotton swab for 15 seconds or given a 30 second rinse with methanol. Mixtures of compounds were found on 2 commercial and 8 model silicone coatings. The hypothesis that silicone components alter glue curing enzymes was tested with curing barnacle glue and with commercial enzymes. In our model, barnacle glue curing involves trypsin-like serine protease(s), which activate enzymes and structural proteins, and a transglutaminase which cross-links glue proteins. Transglutaminase activity was significantly altered upon exposure of curing glue from individual barnacles to silicone eluates. Activity of purified trypsin and, to a greater extent, transglutaminase was significantly altered by relevant concentrations of silicone polymer constituents. Conclusions/Significance Surface-associated silicone compounds can disrupt glue curing and alter enzyme properties. Altered curing of natural glues has potential in fouling management. PMID:21379573

  1. Fibrin glue inhibits migration of ocular surface epithelial cells

    PubMed Central

    Yeung, A M; Faraj, L A; McIntosh, O D; Dhillon, V K; Dua, H S

    2016-01-01

    Purpose Fibrin glue has been used successfully in numerous ophthalmic surgical procedures. Recently, fibrin glue has been used in limbal stem cell transplantation to reduce both operative time and to negate the need for sutures. The aim of this study was to determine the effects of fibrin glue on epithelial cell migration in vitro. Methods Corneoscleral rims were split to retain the epithelial layer, Bowman's layer, and anterior stroma. Rims were cut into eight equal-sized pieces and were placed directly on culture plates or affixed with fibrin glue. Rims were maintained in culture for 25 days and epithelial cell growth was monitored. Cells were photographed to measure area or growth and immunofluorescence staining of explants for fibrin was performed. Results Explants that were glued demonstrated significantly delayed epithelial cell growth and migration as compared with explants without glue. By day 16, all fibrin glue had dissolved and coincided with onset of cell growth from glued explants. Cell growth commenced between days 3 and 4 for control explants without glue and around days 14–16 for explants with fibrin glue. Conclusions Fibrin glue delays epithelial cell migration by acting as a physical barrier and can potentially interfere with explant-derived limbal epithelial cell migration on to the corneal surface. We propose that glue should be used to attach the conjunctival frill of the limbal explant but care should be taken to ensure that the glue does not wrap around the explant if used to secure the explant as well. Strategic use of glue, to attach the recessed conjunctiva, can be advantageous in delaying conjunctival cell migration and reducing the need for sequential sector conjunctival epitheliectomy. PMID:27367746

  2. Treatment of localized neuropathic pain of different etiologies with the 5% lidocaine medicated plaster – a case series

    PubMed Central

    Likar, Rudolf; Demschar, Susanne; Kager, Ingo; Neuwersch, Stefan; Pipam, Wolfgang; Sittl, Reinhard

    2015-01-01

    Objective To assess the efficacy and safety of the topical 5% lidocaine medicated plaster in the treatment of localized neuropathic pain. Study design This was a case series at an Austrian pain clinic, using retrospective analysis. Patients and methods Data of 27 patients treated for localized neuropathic pain with the 5% lidocaine medicated plaster were retrospectively analyzed. Assessment included changes in overall pain intensity, in intensity of different pain qualities, and of hyperalgesia and allodynia, and changes in sleep quality. Results Patients (17 female, ten male; mean age 53.4±11.4 years) presented mainly with dorsalgia (16 patients) or postoperative/posttraumatic pain (seven patients); one patient suffered from both. The mean overall pain intensity prior to treatment with lidocaine medicated plaster was 8.4±1.2 on the 11-point Likert scale. In the majority of cases, the lidocaine plaster was applied concomitantly with preexisting pain medication (81.5% of the patients). During the 6-month observation period, overall mean pain intensity was reduced by almost 5 points (4.98) to 3.5±2.6. Substantial reductions were also observed for neuralgiform pain (5 points from 7.9±2.6 at baseline) and burning pain (3 points from 5.2±4.1). Sleep quality improved from 4.6±2.6 at baseline to 5.5±1.8. Stratification by pain diagnosis showed marked improvements in overall pain intensity for patients with dorsalgia or postoperative/posttraumatic pain. The lidocaine plaster was well tolerated. Conclusion Overall, topical treatment with the 5% lidocaine medicated plaster was associated with effective pain relief and was well tolerated. PMID:25565882

  3. Functional exercise in combination with auricular plaster therapy is more conducive to rehabilitation of menopausal women patients with anxiety disorder

    PubMed Central

    Han, Yubin; Duan, Fugui; Xu, Rongmei; Wang, Yi; Zhang, Hongyu

    2015-01-01

    Objective: Observe the effect of functional exercise in combination with auricular plaster therapy on menopausal women patients with anxiety disorder. Method: Select 45 menopausal women patients with anxiety disorder and then adopt random digital table to divide them into a functional exercise group, an auricular plaster therapy group and a combination group. Each group consists of 15 patients. The patients in the functional exercise group do yoga exercise twice a day; those in the auricular plaster therapy group are provided with the auricular plaster therapy twice a day; those in the combination group do yoga exercise and then they are provided with the auricular plaster therapy twice a day. Before the treatment and after 12 weeks’ treatment, respectively detect and compare the selected patients in the three groups in respect HAMA score, physical function score and mental function score; And the cured patients are followed up for 3 months to compare recurrence rate of each group. Results: After 12 weeks’ treatment, HAMA score, physical function score and mental function score of the combination group are obviously better than those of another two groups (P<0.05); Of the cure rate and the recurrence rate within 3 months, the cure rate of the combination group is higher and the recurrence rate is low. Conclusion: Through the functional rehabilitation exercise in combination with the auricular plaster, the combined curative effect is obviously better than that of single treatment and the clinical recurrence rate is significantly lower than that of single treatment. It shows that the combined treatment method presents obvious synergistic effect and the synergistic treatment is more beneficial to improve the curative effect. PMID:26885051

  4. Analysis of wall plasters and natural sediments from the Neolithic town of Çatalhöyük (Turkey) by a range of analytical techniques

    NASA Astrophysics Data System (ADS)

    Anderson, Emma; Almond, Matthew J.; Matthews, Wendy

    2014-12-01

    Wall plaster sequences from the Neolithic town of Çatalhöyük have been analysed and compared to three types of natural sediment found in the vicinity of the site, using a range of analytical techniques. Block samples containing the plaster sequences were removed from the walls of several different buildings on the East Mound. Sub-samples were examined by IR spectroscopy, X-ray diffraction and X-ray fluorescence to determine the overall mineralogical and elemental composition, whilst thin sections were studied using optical polarising microscopy, IR Microscopy and Environmental Scanning Electron Microscopy with Energy Dispersive X-ray analysis. The results of this study have shown that there are two types of wall plaster found in the sequences and that the sediments used to produce these were obtained from at least two distinct sources. In particular, the presence of clay, calcite and magnesian calcite in the foundation plasters suggested that these were prepared predominantly from a marl source. On the other hand, the finishing plasters were found to contain dolomite with a small amount of clay and no calcite, revealing that softlime was used in their preparation. Whilst marl is located directly below and around Çatalhöyük, the nearest source of softlime is 6.5 km away, an indication that the latter was important to the Neolithic people, possibly due to the whiter colour (5Y 8/1) of this sediment. Furthermore, the same two plaster types were found on each wall of Building 49, the main building studied in this research, and in all five buildings investigated, suggesting that the use of these sources was an established practice for the inhabitants of several different households across the site.

  5. Prediction Model for Impulsive Noise on Structures

    DTIC Science & Technology

    2012-09-01

    construction usually have an interior wall finish of: a) gypsum wallboard (also called plasterboard or drywall), b) plaster or c) wood paneling... Gypsum Plaster , Wall Board 11,67 0.04 NA For simply-supported beams vibrating in their fundamental mode, the value of KS is needed for...Dev of log10(f0) for wood panel interior to be average for wood walls with plaster or gypsum board interior. (8) L(w) based on estimated standard

  6. Studies on use of Copper Slag as Replacement Material for River Sand in Building Constructions

    NASA Astrophysics Data System (ADS)

    Madheswaran, C. K.; Ambily, P. S.; Dattatreya, J. K.; Rajamane, N. P.

    2014-09-01

    This work focuses on the use of copper slag, as a partial replacement of sand for use in cement concrete and building construction. Cement mortar mixtures prepared with fine aggregate made up of different proportions of copper slag and sand were tested for use as masonry mortars and plastering. Three masonry wall panels of dimensions 1 × 1 m were plastered. The studies showed that although copper slag based mortar is suitable for plastering, with the increase in copper slag content, the wastage due to material rebounding from the plastered surfaces increases. It is therefore suggested that the copper slag can be used for plastering of floorings and horizontal up to 50 % by mass of the fine aggregate, and for vertical surfaces, such as, brick/block walls it can be used up to 25 %. In this study on concrete mixtures were prepared with two water cement ratios and different proportions of copper slag ranging from 0 % (for the control mix) to 100 % of fine aggregate. The Concrete mixes were evaluated for workability, density, and compressive strength.

  7. [The effect of curiozin gel and adhesive plaster application on the healing and blood flow dynamics in skin autografts from various areas of body in rats].

    PubMed

    Zadorozhnyĭ, A A; Shtrygol', S Iu; Kataev, S I

    2004-01-01

    The stimulating effect of curiozin gel and plaster application on the engraftment of skin autografts from various areas of body was studied in rats. Curiozin gel in a single dose of 75 mg was used for the daily treatment of autografts over the entire postoperation period of time. The adhesive plaster was applied onto skin autografts for 5 days after skin transplantation. The skin autografts in the test group exhibited normalized volume blood flow dynamics, reduced duration of the inflammatory reaction, and improved the quality of engraftment as compared to the untreated control group. The best healing and blood-flow-normalizing effect was achieved by combined application of curiozin gel and adhesive plaster.

  8. Alternative glues for the production of ATLAS silicon strip modules for the Phase-II upgrade of the ATLAS Inner Detector

    NASA Astrophysics Data System (ADS)

    Poley, L.; Bloch, I.; Edwards, S.; Friedrich, C.; Gregor, I.-M.; Jones, T.; Lacker, H.; Pyatt, S.; Rehnisch, L.; Sperlich, D.; Wilson, J.

    2016-05-01

    The Phase-II upgrade of the ATLAS detector for the High Luminosity Large Hadron Collider (HL-LHC) includes the replacement of the current Inner Detector with an all-silicon tracker consisting of pixel and strip detectors. The current Phase-II detector layout requires the construction of 20,000 strip detector modules consisting of sensor, circuit boards and readout chips, which are connected mechanically using adhesives. The adhesive used initially between readout chips and circuit board is a silver epoxy glue as was used in the current ATLAS SemiConductor Tracker (SCT). However, this glue has several disadvantages, which motivated the search for an alternative. This paper presents a study of six ultra-violet (UV) cure glues and a glue pad for possible use in the assembly of silicon strip detector modules for the ATLAS upgrade. Trials were carried out to determine the ease of use, thermal conduction and shear strength. Samples were thermally cycled, radiation hardness and corrosion resistance were also determined. These investigations led to the exclusion of three UV cure glues as well as the glue pad. Three UV cure glues were found to be possible better alternatives than silver loaded glue. Results from electrical tests of first prototype modules constructed using these glues are presented.

  9. Technological Characterization of Wall Paintings from the A Mithraic Tomb Dated to 4th-5th Century AD, Gargaresc, Libya

    NASA Astrophysics Data System (ADS)

    Abd El Salam, S.; Maniatis, Y.

    2009-04-01

    The excavations of Gargaresc started in 1965 and were one of the most important archaeological sites in Tripoli because it includes a period of about 500 years starting from the 1stc. AD was and continuing until the 5th century AD. The Mithraic tomb is one of the most important outlying monuments of Oea, 200 yards south of the western end of Gargaresc oasis, on the left of the Tripoli-Zuara road between kilometers 5 & 6. The tomb is cut in an outcrop of soft sandstone. The wall paintings found were symbolic to the religion of that period; which contained a mixture of older religions and Christian, and presented the interaction between the artistic and religious elements of that time. Several optical, chemical and mineralogical methods were applied to identify the materials, composition and technology of the plasters and mortars, as well as, the pigments used in the tomb. These are: -OP: Optical microscopy was used as the initial examination of polished cross-sections to identify the structure and microstratigraphy of the plasters and mortars as well as the painted layers. -MCT: Micro-chemical tests were used to identify the type of the plasters and mortars- calcium aluminium silicate and water-soluble salt to identify sulphates, chlorides, carbonates, nitrites and nitrates. -SM: Standard methods for chemical analysis to identify the quantitative and qualitative nature of the plasters and mortars and their mixture. -SEM & EDS: Analytical Scanning electron microscope with energy dispersive x-ray analysis system to examine the micrmorphology and determine the chemical composition of the plasters, pigments and the inclusions. -XRD: X-ray powder diffraction to identify the mineralogical composition of the plasters, mortars and pigments. On the bases of all the data obtained, it was possible to establish the nature of the plasters, mortars and their binder. The examination and analysis gave a full picture about the materials and the approximate ratio of amount of additives to lime used for making the mortars and plasters. In addition the results showed the stratigraphy of the various layers applied. The lime plasters and mortars contained apart from lime as binder quartz grains, charcoal, ironstone, brick and some other inclusions. Furthermore the mineralogical analysis provided information on the main mineralogical phases present in the plasters and pigments. The use of gypsum was detected in some cases but it was identified as a result of conservation. The analytical results provided also information on the deterioration factors and alterations that have affected the materials of the wall paintings and present quite interesting challenges for conservation science.

  10. Rejoining of cut wounds by engineered gelatin-keratin glue.

    PubMed

    Thirupathi Kumara Raja, S; Thiruselvi, T; Sailakshmi, G; Ganesh, S; Gnanamani, A

    2013-08-01

    Rejoining of cut tissue ends of a critical site challenges clinicians. The toxicity, antigenicity, low adhesive strength, flexibility, swelling and cost of the currently employed glue demands an alternative. Engineered gelatin-keratin glue (EGK-glue) described in the present study was found to be suitable for wet tissue approximation. EGK-glue was prepared by engineering gelatin with caffeic acid using EDC and conjugating with keratin by periodate oxidation. UV-visible, (1)H NMR and circular dichroism analyses followed by experiments on gelation time, rheology, gel adhesive strength (in vitro), wet tissue approximation (in vivo), H&E staining of tissue sections at scheduled time intervals and tensile strength of the healed skin were carried out to assess the effectiveness of the EGK-glue in comparison with fibrin glue and cyanoacrylate. Results of UV-visible, NMR and CD analyses confirmed the functionalization and secondary structural changes. Increasing concentration of keratin reduces the gelation time (<15s). Lap-shear test demonstrates the maximum adhesive strength of 16.6±1.2kPa. Results of hemocompatibility and cytocompatibility studies suggested the suitability of the glue for clinical applications. Tissue approximation property assessed using the incision wound model (Wistar strain) in comparison with cyanoacrylate and fibrin glue suggested, that EGK-glue explicitly accelerates the rejoining of tissue with a 1.86 fold increase in skin tensile strength after healing. Imparting quinone moiety to gelatin-keratin conjugates through caffeic acid and a weaker oxidizing agent provides an adhesive glue with appreciable strength, and hemocompatible, cytocompatible and biodegradable properties, which, rejoin the cut tissue ends effectively. EGK-glue obtained in the present study finds wide biomedical/clinical applications. Copyright © 2013 Elsevier B.V. All rights reserved.

  11. SEPALLATA3: the 'glue' for MADS box transcription factor complex formation

    PubMed Central

    Immink, Richard GH; Tonaco, Isabella AN; de Folter, Stefan; Shchennikova, Anna; van Dijk, Aalt DJ; Busscher-Lange, Jacqueline; Borst, Jan W; Angenent, Gerco C

    2009-01-01

    Background Plant MADS box proteins play important roles in a plethora of developmental processes. In order to regulate specific sets of target genes, MADS box proteins dimerize and are thought to assemble into multimeric complexes. In this study a large-scale yeast three-hybrid screen is utilized to provide insight into the higher-order complex formation capacity of the Arabidopsis MADS box family. SEPALLATA3 (SEP3) has been shown to mediate complex formation and, therefore, special attention is paid to this factor in this study. Results In total, 106 multimeric complexes were identified; in more than half of these at least one SEP protein was present. Besides the known complexes involved in determining floral organ identity, various complexes consisting of combinations of proteins known to play a role in floral organ identity specification, and flowering time determination were discovered. The capacity to form this latter type of complex suggests that homeotic factors play essential roles in down-regulation of the MADS box genes involved in floral timing in the flower via negative auto-regulatory loops. Furthermore, various novel complexes were identified that may be important for the direct regulation of the floral transition process. A subsequent detailed analysis of the APETALA3, PISTILLATA, and SEP3 proteins in living plant cells suggests the formation of a multimeric complex in vivo. Conclusions Overall, these results provide strong indications that higher-order complex formation is a general and essential molecular mechanism for plant MADS box protein functioning and attribute a pivotal role to the SEP3 'glue' protein in mediating multimerization. PMID:19243611

  12. Agreement in the determination of preformed wire shape templates on plaster models and customized digital arch form diagrams on digital models.

    PubMed

    Camardella, Leonardo Tavares; Sá, Maiara da Silva Bezerra; Guimarães, Luciana Campos; Vilella, Beatriz de Souza; Vilella, Oswaldo de Vasconcellos

    2018-03-01

    The aim of this study was to verify the accuracy of preformed wire shape templates on plaster models and those of customized digital arch form diagrams on digital models. Twenty pairs of dental plaster models were randomly selected from the archives of the Department of Orthodontics of Federal Fluminense University, Niterói, Rio de Janeiro, Brazil. All plaster model samples were scanned in a plaster model scanner to create the respective digital models. Three examiners defined the arch form on the mandibular arch of these models by selecting the ideal preformed wire shape template on each plaster model or by making a customized digital arch form on the digital models using a digital arch form customization tool. These 2 arch forms were superimposed by the best-fit method. The greatest differences in the 6 regions on the superimposed arches were evaluated. Each examiner presented a descriptive analysis with the means, standard deviation, and minimum and maximum intervals of the differences on the superimpositions. Intraclass correlation coefficient and paired t tests were used to evaluate the accuracy of the superimpositions. Among the 6 regions analyzed in the superimpositions, the largest differences in the anterior and premolar regions were considered clinically insignificant, whereas the largest differences in the right molar region, especially the second molar area, were considered clinically significant by all 3 examiners. The intraclass correlation coefficients showed a weak correlation in the premolar region and moderate correlations in the anterior and molar regions. The paired t test showed statistically significant differences in the left anterior and premolar regions. The superimpositions between the arch forms on plaster and digital models were considered accurate, and the differences were not clinically significant, with the exception of the second molar area. Despite the favorable results, the requirement of correcting some software problems may hamper the transition from plaster to digital models. Copyright © 2017 American Association of Orthodontists. Published by Elsevier Inc. All rights reserved.

  13. Factors contributing to the temperature beneath plaster or fiberglass cast material

    PubMed Central

    Hutchinson, Michael J; Hutchinson, Mark R

    2008-01-01

    Background Most cast materials mature and harden via an exothermic reaction. Although rare, thermal injuries secondary to casting can occur. The purpose of this study was to evaluate factors that contribute to the elevated temperature beneath a cast and, more specifically, evaluate the differences of modern casting materials including fiberglass and prefabricated splints. Methods The temperature beneath various types (plaster, fiberglass, and fiberglass splints), brands, and thickness of cast material were measured after they were applied over thermometer which was on the surface of a single diameter and thickness PVC tube. A single layer of cotton stockinette with variable layers and types of cast padding were placed prior to application of the cast. Serial temperature measurements were made as the cast matured and reached peak temperature. Time to peak, duration of peak, and peak temperature were noted. Additional tests included varying the dip water temperature and assessing external insulating factors. Ambient temperature, ambient humidity and dip water freshness were controlled. Results Outcomes revealed that material type, cast thickness, and dip water temperature played key roles regarding the temperature beneath the cast. Faster setting plasters achieved peak temperature quicker and at a higher level than slower setting plasters. Thicker fiberglass and plaster casts led to greater peak temperature levels. Likewise increasing dip-water temperature led to elevated temperatures. The thickness and type of cast padding had less of an effect for all materials. With a definition of thermal injury risk of skin injury being greater than 49 degrees Celsius, we found that thick casts of extra fast setting plaster consistently approached dangerous levels (greater than 49 degrees for an extended period). Indeed a cast of extra-fast setting plaster, 20 layers thick, placed on a pillow during maturation maintained temperatures over 50 degrees of Celsius for over 20 minutes. Conclusion Clinicians should be cautious when applying thick casts with warm dip water. Fast setting plasters have increased risk of thermal injury while brand does not appear to play a significant role. Prefabricated fiberglass splints appear to be safer than circumferential casts. The greatest risk of thermal injury occurs when thick casts are allowed to mature while resting on pillow. PMID:18298851

  14. Photoinduced Bioorthogonal 1,3-Dipolar Poly-cycloaddition Promoted by Oxyanionic Substrates for Spatiotemporal Operation of Molecular Glues.

    PubMed

    Hatano, Junichi; Okuro, Kou; Aida, Takuzo

    2016-01-04

    PGlue(PZ), a pyrazoline (PZ)-based fluorescent adhesive which can be generated spatiotemporally in living systems, was developed. Since PGlue(PZ) carries many guanidinium ion (Gu(+)) pendants, it strongly adheres to various oxyanionic substrates through a multivalent salt-bridge interaction. PGlue(PZ) is given by bioorthogonal photopolymerization of a Gu(+)-appended monomer (Glue(TZ)), bearing tetrazole (TZ) and olefinic termini. Upon exposure to UV light, Glue(TZ) transforms into a nitrileimine (NI) intermediate (Glue(NI)), which is eligible for 1,3-dipolar polycycloaddition. However, Glue(NI) in aqueous media can concomitantly be deactivated into Glue(WA) by the addition of water, and the polymerization hardly occurs unless Glue(NI) is concentrated. We found that, even under high dilution, Glue(NI) is concentrated on oxyanionic substrates to a sufficient level for the polymerization, so that their surfaces can be point-specifically functionalized with PGlue(PZ) by the use of a focused beam of UV light. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  15. Bio-inspired Nanoparticulate Medical Glues for Minimally Invasive Tissue Repair

    PubMed Central

    Lee, Yuhan; Xu, Chenjie; Sebastin, Monisha; Lee, Albert; Holwell, Nathan; Xu, Calvin; Miranda-Nieves, David; Mu, Luye; Lin, Charles

    2015-01-01

    Delivery of tissue glues through small-bore needles or trocars is critical for sealing holes, affixing medical devices, or attaching tissues together during minimally invasive surgeries. Inspired by the granule-packaged glue delivery system of sandcastle worms, we have developed a nanoparticulate formulation of a viscous hydrophobic light-activated adhesive based on poly(glycerol sebacate)-acrylate. Negatively charged alginate was used to stabilize the nanoparticulate surface to significantly reduce its viscosity and to maximize injectability through small-bore needles. The nanoparticulate glues can be concentrated to ~30w/v% dispersions in water that remain localized following injection. With the trigger of a positively charged polymer (e.g., protamine), the nanoparticulate glues can quickly assemble into a viscous glue that exhibits rheological, mechanical and adhesive properties resembling the native poly(glycerol sebacate)-acrylate based glues. This platform should be useful to enable the delivery of viscous glues to augment or replace sutures and staples during minimally invasive procedures. PMID:26227833

  16. Bioinspired Nanoparticulate Medical Glues for Minimally Invasive Tissue Repair.

    PubMed

    Lee, Yuhan; Xu, Chenjie; Sebastin, Monisha; Lee, Albert; Holwell, Nathan; Xu, Calvin; Miranda Nieves, David; Mu, Luye; Langer, Robert S; Lin, Charles; Karp, Jeffrey M

    2015-11-18

    Delivery of tissue glues through small-bore needles or trocars is critical for sealing holes, affixing medical devices, or attaching tissues together during minimally invasive surgeries. Inspired by the granule-packaged glue delivery system of sandcastle worms, a nanoparticulate formulation of a viscous hydrophobic light-activated adhesive based on poly(glycerol sebacate)-acrylate is developed. Negatively charged alginate is used to stabilize the nanoparticulate surface to significantly reduce its viscosity and to maximize injectability through small-bore needles. The nanoparticulate glues can be concentrated to ≈30 w/v% dispersions in water that remain localized following injection. With the trigger of a positively charged polymer (e.g., protamine), the nanoparticulate glues can quickly assemble into a viscous glue that exhibits rheological, mechanical, and adhesive properties resembling the native poly(glycerol sebacate)-acrylate based glues. This platform should be useful to enable the delivery of viscous glues to augment or replace sutures and staples during minimally invasive procedures. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  17. Plaster core washout tool

    NASA Technical Reports Server (NTRS)

    Heisman, R. M.; Keir, A. R.; Teramura, K.

    1977-01-01

    Tool powered by pressurized water or air removes water soluble plaster lining from Kevlar/epoxy duct. Rotating plastic cutterhead with sealed end fitting connects flexible shaft that allows tool to be used with curved ducts.

  18. Gray level co-occurrence and random forest algorithm-based gender determination with maxillary tooth plaster images.

    PubMed

    Akkoç, Betül; Arslan, Ahmet; Kök, Hatice

    2016-06-01

    Gender is one of the intrinsic properties of identity, with performance enhancement reducing the cluster when a search is performed. Teeth have durable and resistant structure, and as such are important sources of identification in disasters (accident, fire, etc.). In this study, gender determination is accomplished by maxillary tooth plaster models of 40 people (20 males and 20 females). The images of tooth plaster models are taken with a lighting mechanism set-up. A gray level co-occurrence matrix of the image with segmentation is formed and classified via a Random Forest (RF) algorithm by extracting pertinent features of the matrix. Automatic gender determination has a 90% success rate, with an applicable system to determine gender from maxillary tooth plaster images. Copyright © 2016 Elsevier Ltd. All rights reserved.

  19. [The reliability of dento-maxillary models created by cone-beam CT and rapid prototyping:a comparative study].

    PubMed

    Lv, Yan; Yan, Bin; Wang, Lin; Lou, Dong-hua

    2012-04-01

    To analyze the reliability of the dento-maxillary models created by cone-beam CT and rapid prototyping (RP). Plaster models were obtained from 20 orthodontic patients who had been scanned by cone-beam CT and 3-D models were formed after the calculation and reconstruction of software. Then, computerized composite models (RP models) were produced by rapid prototyping technique. The crown widths, dental arch widths and dental arch lengths on each plaster model, 3-D model and RP model were measured, followed by statistical analysis with SPSS17.0 software package. For crown widths, dental arch lengths and crowding, there were significant differences(P<0.05) among the 3 models, but the dental arch widths were on the contrary. Measurements on 3-D models were significantly smaller than those on other two models(P<0.05). Compared with 3-D models, RP models had more numbers which were not significantly different from those on plaster models(P>0.05). The regression coefficient among three models were significantly different(P<0.01), ranging from 0.8 to 0.9. But between RP and plaster models was bigger than that between 3-D and plaster models. There is high consistency within 3 models, while some differences were accepted in clinic. Therefore, it is possible to substitute 3-D and RP models for plaster models in order to save storage space and improve efficiency.

  20. The application of multi-baseline digital close-range photogrammetry in three-dimensional imaging and measurement of dental casts.

    PubMed

    Fu, Xiaoming; Peng, Chun; Li, Zan; Liu, Shan; Tan, Minmin; Song, Jinlin

    2017-01-01

    To explore a new technique for reconstructing and measuring three-dimensional (3D) models of orthodontic plaster casts using multi-baseline digital close-range photogrammetry (MBDCRP) with a single-lens reflex camera. Thirty sets of orthodontic plaster casts that do not exhibit severe horizontal overlap (>2 mm) between any two teeth were recorded by a single-lens reflex camera with 72 pictures taken in different directions. The 3D models of these casts were reconstructed and measured using the open source software MeshLab. These parameters, including mesio-distal crown diameter, arch width, and arch perimeter, were recorded six times on both the 3D digital models and on plaster casts by two examiners. Statistical analysis was carried out using the Bland-Altman method to measure agreement between the novel method and the traditional calliper method by calculating the differences between mean values. The average differences between the measurements of the photogrammetric 3D models and the plaster casts were 0.011-0.402mm. The mean differences between measurements obtained by the photogrammetric 3D models and the dental casts were not significant except for the lower arch perimeter (P>0.05), and all the differences were regarded as clinically acceptable (<0.5 mm). Measurements obtained by MBDCRP are compared well with those obtained from plaster casts, indicating that MBDCRP is an alternate way to store and measure dental plaster casts without severe horizontal overlap between any two teeth.

  1. Plaster-Wrap Dragons

    ERIC Educational Resources Information Center

    Vance, Shelly

    2012-01-01

    In this article, the author describes how her students constructed a three-dimensional sculpture of a dragon using plaster wrap and other materials. The dragons were formed from modest means--using only a toilet-paper tube, newsprint, tape and wire.

  2. Research on preparation of phosphate-modified animal glue binder for foundry use

    NASA Astrophysics Data System (ADS)

    Wang, Tian-Shu; Liu, Wei-Hua; Li, Ying-Min

    2018-03-01

    In this paper, three phosphates were used as modifiers to modify animal glue binder. The structural characteristics and thermal properties of animal glue binder treated with phosphates were studied by Fourier transform-infrared spectroscopy, gel permeation chromatography and derivative thermogravimetric analysis. The results showed that the modified animal glue binder had better sand tensile strength and lower viscosity than untreated animal glue binder. The best modification process was as follows: the optimal amount of sodium carbonate was 4 wt% to animal glue; the optimal weight ratio of the modifiers was sodium pyrophosphate : sodium tripolyphosphate : sodium hexametaphosphate : animal glue = 3 : 3 : 4 : 100, and the optimal reaction should be performed at 80°C for a reaction time of 120 min. A final tensile strength of approximately 3.20 MPa was achieved and the viscosity value was approximately 880 mPa s.

  3. Albumen Glue, New Material for Conjunctival Graft Surgery, an Animal Experiment

    NASA Astrophysics Data System (ADS)

    Kartiwa, A.; Miraprahesti, R.; Sovani, I.; Enus, S.; Boediono, A.

    2017-02-01

    Attach conjunctival graft commonly used are suture technique and fibrin glue. This study was to investigate albumen glue as an alternative to suture technique in attaching conjunctival graft in rabbits. Aim of this study was to compare the conjunctival wound healing between albumen glue and suture technique in rabbit eye as a model. There was an experimental animal study included 32 eyes (16 rabbits) in PT. Bio Farma (Persero) and Histology Laboratory, Faculty of Medicine, Padjadjaran University from March 2014 to July 2104. The study consisted of albumen glue group and suture technique group. The examination included the comparison of conjunctival graft attachment and histologic examination by microscopically was done to obtain the wound gap, then analyze by Mann-Whitney test. The results indicated that the graft attachment was significantly better-using albumen glue (grade 4) compared to suture (grade 2-3) on day-1 after surgery (p=0,000). The wound gap was smaller using albumen glue (0-0,33 μm versus 5,33-14 μm ; p=0,0005) on 10 minutes after surgery and 0 μm versus 0,33-4 μm ; p=0,0005 on day-7 after surgery. In conclusion, the graft attachment using albumen glue was better and the wound gap was smaller using albumen glue than suture technique.

  4. Usefulness of a New Gelatin Glue Sealant System for Dural Closure in a Rat Durotomy Model

    PubMed Central

    KAWAI, Hisashi; NAKAGAWA, Ichiro; NISHIMURA, Fumihiko; MOTOYAMA, Yasushi; PARK, Young-Su; NAKAMURA, Mitsutoshi; NAKASE, Hiroyuki; SUZUKI, Shuko; IKADA, Yoshito

    2014-01-01

    Watertight dural closure is imperative after neurosurgical procedures, because inadequately treated leakage of cerebrospinal fluid (CSF) can have serious consequences. We used a rat durotomy model to test the usefulness of a new gelatin glue as a dural sealant in a rat model of transdural CSF leakage. All rats were randomly divided into one of the following three treatment groups: no application (control group: N = 18), application of fibrin glue (fibrin glue group: N = 18), and application of the new gelatin glue (new gelatin glue group: N = 18). The craniotomy side was re-opened, and CSF leakage was checked and recorded at 1, 7, and 28 days postoperatively. The new gelatin glue was adequate for stopping CSF leakage; no leakage was observed at postoperative days 1 or 7, and leakage was observed in only one rat at postoperative day 28. This result was statistically significant when compared to the control group (P = 0.002, P = 0.015, P = 0.015, respectively). The pathologic score of the new gelatin group was not different from that of the control or fibrin glue groups. We conclude that our new gelatin glue provides effective watertight closure 1, 7, and 28 days after operation in the rat durotomy model. PMID:25070015

  5. Archaeomagnetic studies in central Mexico—dating of Mesoamerican lime-plasters

    NASA Astrophysics Data System (ADS)

    Hueda-Tanabe, Y.; Soler-Arechalde, A. M.; Urrutia-Fucugauchi, J.; Barba, L.; Manzanilla, L.; Rebolledo-Vieyra, M.; Goguitchaichvili, A.

    2004-11-01

    For the first time results of an archaeomagnetic study of unburned lime-plasters from Teotihuacan and Tenochtitlan in central Mesoamerica are presented. Plasters made of lime, lithic clasts and water, appear during the Formative Period and were used for a variety of purposes in floors, sculptures, ceramics and supporting media for mural paintings in the Oaxaca and Maya area. In Central Mexico, grinded volcanic scoria rich in iron minerals is incorporated into the lime-plasters mixture. Samples were selected from two archaeological excavation projects in the Teopancazco residential compound of Teotihuacan and the large multi-stage structure of Templo Mayor in Tenochtitlan, where chronological information is available. The intensity of remanent magnetization (natural remanent magnetization (NRM)) and low-field susceptibility are weak reflecting low relative content of magnetic minerals. NRM directions are well grouped and alternating field demagnetization shows single or two-component magnetizations. Rockmagnetic experiments point to fine-grained titanomagnetites with pseudo-single domain behavior. Anisotropy of magnetic susceptibility (AMS) measurements document a depositional fabric, with normal to free-surface minimum AMS axes. Characteristic mean site directions were correlated to the paleosecular variation curve for Mesoamerica. Data from Templo Mayor reflect recent tilting of the structures. Teopancazco mean site declinations show good correspondence with the reference curve, in agreement with the radiocarbon dating. Dates for four stages of Teotihuacan occupancy based on the study of lime-plasters range from AD 350 to 550. A date for a possible Mazapa occupation around AD 850 or 950 is also suggested based on the archaeomagnetic correlation. The archaeomagnetic record of a plaster floor in Teopancazco differed from the other nearby sites pointing to a thermoremanent magnetization; comparison with the reference curve suggests dates around AD 1375 or 1415. The burning of the stucco floor likely occurred during a late re-occupation of the site by the Aztecs. Our results suggest that archaeomagnetic dating can be applied to lime-plasters, which are materials widely employed in Mesoamerica.

  6. Analysis of wall plasters and natural sediments from the Neolithic town of Çatalhöyük (Turkey) by a range of analytical techniques.

    PubMed

    Anderson, Emma; Almond, Matthew J; Matthews, Wendy

    2014-12-10

    Wall plaster sequences from the Neolithic town of Çatalhöyük have been analysed and compared to three types of natural sediment found in the vicinity of the site, using a range of analytical techniques. Block samples containing the plaster sequences were removed from the walls of several different buildings on the East Mound. Sub-samples were examined by IR spectroscopy, X-ray diffraction and X-ray fluorescence to determine the overall mineralogical and elemental composition, whilst thin sections were studied using optical polarising microscopy, IR Microscopy and Environmental Scanning Electron Microscopy with Energy Dispersive X-ray analysis. The results of this study have shown that there are two types of wall plaster found in the sequences and that the sediments used to produce these were obtained from at least two distinct sources. In particular, the presence of clay, calcite and magnesian calcite in the foundation plasters suggested that these were prepared predominantly from a marl source. On the other hand, the finishing plasters were found to contain dolomite with a small amount of clay and no calcite, revealing that softlime was used in their preparation. Whilst marl is located directly below and around Çatalhöyük, the nearest source of softlime is 6.5km away, an indication that the latter was important to the Neolithic people, possibly due to the whiter colour (5Y 8/1) of this sediment. Furthermore, the same two plaster types were found on each wall of Building 49, the main building studied in this research, and in all five buildings investigated, suggesting that the use of these sources was an established practice for the inhabitants of several different households across the site. Copyright © 2014 Elsevier B.V. All rights reserved.

  7. Outcomes of Pin and Plaster Versus Locking Plate in Distal Radius Intraarticular Fractures

    PubMed Central

    Bahari-Kashani, Mahmoud; Taraz-Jamshidy, Mohammad Hosein; Rahimi, Hassan; Ashraf, Hami; Mirkazemy, Masoud; Fatehi, Amirreza; Asadian, Mariam; Rezazade, Jafar

    2013-01-01

    Background Distal radius fractures are among the most prevalent fractures predictive of probable occurrence of other osteoporotic fractures. They are treated via a variety of methods, but the best treatment has not been defined yet. Objectives This study was performed to compare the results of open reduction and internal fixation with locking plates versus the pin and plaster method. Materials and Methods In this prospective study, 114 patients aged 40 to 60 years with Fernandez type III fracture referring to Imam-Reza and Mehr hospitals of Mashhad from 2009 to 2011, were selected randomly; after obtaining informed consent, they were treated with pin and plaster fixation (n = 57) or internal fixation with the volar locking plate (n = 57). They were compared at the one year follow up. Demographic features and standard radiographic indices were recorded and MAYO, DASH and SF - 36 tests were performed. Data was analyzed by SPSS software version 13, with descriptive indices, Mann-Whitney and Chi-square tests. Results SF-36 test demonstrated a better general health (P < 0.001), mental health (P = 0.006), physical functioning (P < 0.001), social functioning (P < 0.001) and energy/fatigue (P < 0.001) in LCP group. However, pain (P = 0.647) was not significantly different between the groups. Physical limitation (P < 0.001) and emotional limitation (P < 0.001) were greater in the pin and plaster group. Also, in the LCP group mean MAYO score (P < 0.001) was more than pin and plaster group. Mean DASH score was not different between the groups (P = 0.218). The rate of acceptable results of radiographic indices (P < 0.001), grip strength (P < 0.001) and range of motion in supination-pronation (P < 0.001) in LCP method were better than the pin and plaster method. Conclusions In treatment of intra-articular distal radius fractures in middle-aged patients internal fixation with locking plates may be prefered to pin and plaster as the treatment of choice. PMID:24350132

  8. Safety of Synthetic Glue Used for Laparoscopic Prolapse Treatment.

    PubMed

    Sarasa Castelló, Núria; Toth, Alexandra; Canis, Michel; Botchorishvilli, Revaz

    2017-12-29

    We detected mesh erosion and serious postoperative complications in 3 women after performing laparoscopic promontofixation (LPF) using glue for mesh fixation. Glue, largely used in hernia surgery repair, is proposed by some gynecologic surgeons because it saves time and is easier to use than traditional sutures. We report 3 cases of postoperative complications after LPF in which glue had been used and provide research in the published literature about the use of glue in LPF. A research of glue use in gynecology mesh fixation was performed through PubMed on October 2016. The search was done using the Medical Subject Heading terms "POP" & "Laparoscopy" & "surgical Mesh" and the word either "glue" or "adhesive. Only 2 articles were found: Willecocq et al [1] and Estrade et al [2]. Neither study focused on postoperative complications. In this publication, we accurately edited video surgeries with an instructive purpose. University Hospital of Clermont-Ferrand, France. Patient A, a 65-year-old woman, complained of pelvic pain and vaginal discharge 1 month after LPF (polypropylene mesh and glue had been used). Wall mesh exposure and purulent discharge were noted. She received antibiotics and underwent mesh ablation surgery; debris of the glue was easily identified. Patient B, a 65-year-old lady with previous hysterectomy consulted for a bulging feeling in her vagina (classification: cystocele +2; rectocele +3 stage). An LPF was performed using polypropylene soft nonabsorbable mesh and glue. One month later, an apical defect of vaginal epithelialization was detected; she received long estrogenic local treatment but had to undergo surgery when presenting malodorous discharge and mesh exposure. The exposed mesh was removed, and pieces of glue were identified, having avoided mesh attachment. Patient C had a previous abdominal hysterectomy and promontofixation using a polyester mesh with glue. She consulted to us for vaginal mesh erosion covered with purulent discharge 3.5 years after LPF in another center. At the surgery, 1 cm of the prosthesis was identified in the vagina, dissected, and sutured. One year later, she consulted for dyspareunia and purulent discharge; vaginal rigid mesh exposure with an epithelization defect and inflammatory signs was seen. During laparoscopy, prosthetic exposition and glue debris on the prosthesis were identified. In all 3 cases, debris of glue were identified in the no integrated mesh area. The suggested reasons of exposure can be the excessive amount of surgical glue applied. Moreover, a large amount of glue may be impairing tissue ingrowth through the mesh pores, causing low fibrosis and poor tissue integration [3]. Glue seems to prevent fibrosis from occurring. Its use in pelvic organ prolapse laparoscopic mesh fixation should be done with caution. No prospective studies reporting long-term comorbidities and results have been published. Copyright © 2017 American Association of Gynecologic Laparoscopists. Published by Elsevier Inc. All rights reserved.

  9. Asbestos in Plaster and Wall Systems

    EPA Pesticide Factsheets

    This collection of letters and clarification on final rules provides guidance on Asbestos National Emissions Standard for Hazardous Air Pollutants for asbestos-containing join compounds, and asbestos-containing materials found in plaster and wall systems.

  10. 37. PRESSING TILES FROM PLASTER MOLDS, USING A HAND PRESS ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    37. PRESSING TILES FROM PLASTER MOLDS, USING A HAND PRESS CONSTRUCTED IN 1986. - Moravian Pottery & Tile Works, Southwest side of State Route 313 (Swamp Road), Northwest of East Court Street, Doylestown, Bucks County, PA

  11. Hygrothermal analysis of surface layers of historical masonry

    NASA Astrophysics Data System (ADS)

    Kočí, Václav; Maděra, Jiří; Keppert, Martin; Černý, Robert

    2017-11-01

    The paper deals with the hygrothermal analysis of surface layers of historical masonry. Solid brick provided with a traditional and two modified lime-based plasters is studied. The heat and moisture transport in the envelope is induced by an exposure of the wall from the exterior side to dynamic climatic conditions of Olomouc, Czech Republic. The transport processes are described using diffusion type of mathematical model based on experimentally determined material properties. The computational results indicate that hygric transport and accumulation properties of exterior plasters affect the hygrothermal performance of the underlying solid brick in a very significant way, being able to regulate the amount of transported moisture. The modified lime plasters are not found generally superior to the traditional lime plasters in that respect. Therefore, their suitability for historical masonry should be assessed case by case, with a particular attention to the climatic conditions and to the properties of the load bearing structure.

  12. Chemical and mineralogical characterization of archaeologicam building materials from Seyitomer Hoyuk Kutahya, Turkey.

    NASA Astrophysics Data System (ADS)

    Bilgen, Nejat; Olgun, Asim

    This paper focuses on the spectroscopic and thermal analysis of the archaeological samples of mortar and plaster from middle Bronze Age and Achaemenid period in Seyitömer Höyük. The composition of the samples was investigated using X-ray diffraction (XRD), scanning electron microscopy (SEM), Fourier transform infrared (FTIR) spectroscopy and thermogravimetric thermal analysis (TG-DTA). The results showed that human used different types of raw materials in the preperation of the mortar and plaster in the Middle Bronze Age and Achaemenid period. The material used in middle Bronze Age contains muscovite whereas the material in Achaemenid period contains albite. Although, the chemical composition of the mortar and plaster used in the period were similar, the calcium content of the plaster is relatively higher than the one of the mortar indicating people's awareness of the binding properties of calcite.

  13. Glue Guns: Aiming for Safety

    ERIC Educational Resources Information Center

    Roy, Ken

    2010-01-01

    While glue guns are very useful, there are safety issues. Regardless of the temperature setting, glue guns can burn skin. The teacher should demonstrate and supervise the use of glue guns and have a plan should a student get burned. There should be an initial first aid protocol in place, followed by a visit to the school nurse. An accident report…

  14. The GlueX DIRC detector

    NASA Astrophysics Data System (ADS)

    Barbosa, F.; Bessuille, J.; Chudakov, E.; Dzhygadlo, R.; Fanelli, C.; Frye, J.; Hardin, J.; Kelsey, J.; Patsyuk, M.; Schwarz, C.; Schwiening, J.; Stevens, J.; Shepherd, M.; Whitlatch, T.; Williams, M.

    2017-12-01

    The GlueX DIRC (Detection of Internally Reflected Cherenkov light) detector is being developed to upgrade the particle identification capabilities in the forward region of the GlueX experiment at Jefferson Lab. The GlueX DIRC will utilize four existing decommissioned BaBar DIRC bar boxes, which will be oriented to form a plane roughly 4 m away from the fixed target of the experiment. A new photon camera has been designed that is based on the SuperB FDIRC prototype. The full GlueX DIRC system will consist of two such cameras, with the first planned to be built and installed in 2017. We present the current status of the design and R&D, along with the future plans of the GlueX DIRC detector.

  15. The application of multi-baseline digital close-range photogrammetry in three-dimensional imaging and measurement of dental casts

    PubMed Central

    Li, Zan; Liu, Shan; Tan, Minmin; Song, Jinlin

    2017-01-01

    Objective To explore a new technique for reconstructing and measuring three-dimensional (3D) models of orthodontic plaster casts using multi-baseline digital close-range photogrammetry (MBDCRP) with a single-lens reflex camera. Study design Thirty sets of orthodontic plaster casts that do not exhibit severe horizontal overlap (>2 mm) between any two teeth were recorded by a single-lens reflex camera with 72 pictures taken in different directions. The 3D models of these casts were reconstructed and measured using the open source software MeshLab. These parameters, including mesio-distal crown diameter, arch width, and arch perimeter, were recorded six times on both the 3D digital models and on plaster casts by two examiners. Statistical analysis was carried out using the Bland–Altman method to measure agreement between the novel method and the traditional calliper method by calculating the differences between mean values. Results The average differences between the measurements of the photogrammetric 3D models and the plaster casts were 0.011–0.402mm. The mean differences between measurements obtained by the photogrammetric 3D models and the dental casts were not significant except for the lower arch perimeter (P>0.05), and all the differences were regarded as clinically acceptable (<0.5 mm). Conclusions Measurements obtained by MBDCRP are compared well with those obtained from plaster casts, indicating that MBDCRP is an alternate way to store and measure dental plaster casts without severe horizontal overlap between any two teeth. PMID:28640827

  16. 14. DETAIL OF SOUTHWEST FRONT OF WAREHOUSE, SHOWING CORRUGATED PLASTER/ASBESTOS ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    14. DETAIL OF SOUTHWEST FRONT OF WAREHOUSE, SHOWING CORRUGATED PLASTER/ASBESTOS WALLS, WINDOWS AND ROOF. VIEW TO NORTHEAST. - Commercial & Industrial Buildings, International Harvester Company Showroom, Office & Warehouse, 10 South Main Street, Dubuque, Dubuque County, IA

  17. A Fresco Sampler.

    ERIC Educational Resources Information Center

    Leshnoff, Susan K.

    1990-01-01

    Describes how third grade students learned about fresco paintings in Pompeii and made their own frescoes by pouring plaster into styrofoam trays and painting the surface. Students discovered they could control the paint better because of the porous surface of the plaster. (KM)

  18. Plaster, Portraits and Pots.

    ERIC Educational Resources Information Center

    Schimsky, Marc

    1982-01-01

    Describes an art activity in which junior high school students make portrait pots using plaster casts and clay. Each student created a reflection of his or her personality in clay. Specific teaching methods and ways of working with materials are discussed. (AM)

  19. Health hazards in the production and processing of some fibers, resins, and plastics in Bulgaria.

    PubMed Central

    Spassovski, M

    1976-01-01

    Results of the toxicological studies of working conditions, general and professional morbidity, and complex examinations carried out on workers engaged in the production of polyamides, polyacrylonitrile fibers, polyester fibers and poly (vinyl chloride) resin, urea-formaldehyde glue, glass fibre materials and polyurethane resins are given. An extremely high occupational hazard for workers in the production of poly (vinyl chloride) resin and porous materials from polyurethane resins and urea-formaldehyde glue has been established. Cases of vinyl chloride disease, poisoning from formaldehyde, isocyanates, and styrene were noted. Prophylactic measures were taken in Bulgaria to lessen the occupational hazard in the productions as set forth included limitation of the work day to 6 hr, free food, additional bonus and leave, and annual physical examinations of workers. PMID:1026405

  20. Clinical evaluations of complete autologous fibrin glue, produced by the CryoSeal® FS system, and polyglycolic acid sheets as wound coverings after oral surgery.

    PubMed

    Kouketsu, Atsumu; Nogami, Shinnosuke; Yamada-Fujiwara, Minami; Nagai, Hirokazu; Yamauchi, Kensuke; Mori, Shiro; Miyashita, Hitoshi; Kawai, Tadashi; Matsui, Aritsune; Kataoka, Yoshihiro; Satomi, Norihisa; Ezoe, Yushi; Abe, Satoko; Takeda, Yuri; Tone, Takeshi; Hirayama, Bunnichi; Kurobane, Tsuyoshi; Tashiro, Kazuki; Yanagisawa, Yuta; Takahashi, Tetsu

    2017-09-01

    The CryoSeal ® FS System has been recently introduced as an automated device for the production of complete fibrin glue from autologous plasma, rather than from pool allogenic or cattle blood, to prevent viral infection and allergic reaction. We evaluated the effectiveness of complete autologous fibrin glue and polyglycolic acid (PGA) sheet wound coverings in mucosa defect oral surgery. Postoperative pain, scar contracture, ingestion, tongue dyskinesia, and postoperative bleeding were evaluated in 12 patients who underwent oral (including the tongue) mucosa excision, and received a PGA sheet and an autologous fibrin glue covering. They were compared with 12 patients who received a PGA sheet and commercial allogenic fibrin glue. All cases in the complete autologous fibrin glue group demonstrated good wound healing without complications such as local infection or incomplete cure. All evaluated clinical measures in this group were similar or superior to the commercial allogenic fibrin glue group. Coagulation and adhesion quality achieved with this method was comparable to that with a PGA sheet and commercial fibrin glue. Covering oral surgery wounds with complete autologous fibrin glue produced by an automated device was convenient, safe, and reduced the risk of viral infection and allergic reaction associated with conventional techniques. Copyright © 2017 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  1. Evidence from Multiple Species that Spider Silk Glue Component ASG2 is a Spidroin

    PubMed Central

    Collin, Matthew A.; Clarke, Thomas H.; Ayoub, Nadia A.; Hayashi, Cheryl Y.

    2016-01-01

    Spiders in the superfamily Araneoidea produce viscous glue from aggregate silk glands. Aggregate glue coats prey-capture threads and hampers the escape of prey from webs, thereby increasing the foraging success of spiders. cDNAs for Aggregate Spider Glue 1 (ASG1) and 2 (ASG2) have been previously described from the golden orb-weaver, Nephila clavipes, and Western black widow, Latrodectus hesperus. To further investigate aggregate glues, we assembled ASG1 and ASG2 from genomic target capture libraries constructed from three species of cob-web weavers and three species of orb-web weavers, all araneoids. We show that ASG1 is unlikely to be a glue, but rather is part of a widespread arthropod gene family, the peritrophic matrix proteins. For ASG2, we demonstrate its remarkable architectural and sequence similarities to spider silk fibroins, indicating that ASG2 is a member of the spidroin gene family. Thus, spidroins have diversified into glues in addition to task-specific, high performance fibers. PMID:26875681

  2. Spiders Tune Glue Viscosity to Maximize Adhesion.

    PubMed

    Amarpuri, Gaurav; Zhang, Ci; Diaz, Candido; Opell, Brent D; Blackledge, Todd A; Dhinojwala, Ali

    2015-11-24

    Adhesion in humid conditions is a fundamental challenge to both natural and synthetic adhesives. Yet, glue from most spider species becomes stickier as humidity increases. We find the adhesion of spider glue, from five diverse spider species, maximizes at very different humidities that matches their foraging habitats. By using high-speed imaging and spreading power law, we find that the glue viscosity varies over 5 orders of magnitude with humidity for each species, yet the viscosity at maximal adhesion for each species is nearly identical, 10(5)-10(6) cP. Many natural systems take advantage of viscosity to improve functional response, but spider glue's humidity responsiveness is a novel adaptation that makes the glue stickiest in each species' preferred habitat. This tuning is achieved by a combination of proteins and hygroscopic organic salts that determines water uptake in the glue. We therefore anticipate that manipulation of polymer-salts interaction to control viscosity can provide a simple mechanism to design humidity responsive smart adhesives.

  3. The GlueX DIRC detector

    DOE PAGES

    Barbosa, F.; Bessuille, J.; Chudakov, E.; ...

    2017-02-03

    We present the GlueX DIRC (Detection of Internally Reflected Cherenkov light) detector that is being developed to upgrade the particle identification capabilities in the forward region of the GlueX experiment at Jefferson Lab. The GlueX DIRC will utilize four existing decommissioned BaBar DIRC bar boxes, which will be oriented to form a plane roughly 4 m away from the fixed target of the experiment. A new photon camera has been designed that is based on the SuperB FDIRC prototype. The full GlueX DIRC system will consist of two such cameras, with the first planned to be built and installed inmore » 2017. In addition, we present the current status of the design and R&D, along with the future plans of the GlueX DIRC detector.« less

  4. Treatment of unicameral bone cysts by curettage and packing with plaster-of-Paris pellets. 1978.

    PubMed

    Peltier, Leonard F; Jones, Richard H

    2004-05-01

    Long-term follow-up of twenty-six patients with unicameral bone cysts treated by curettage and packing with plaster-of-Paris pellets showed a recurrence in only two cases and no serious complications.

  5. The comparative risk of developing postoperative complications in patients with distal radius fractures following different treatment modalities

    PubMed Central

    Qiu, Wen-Jun; Li, Yi-Fan; Ji, Yun-Han; Xu, Wei; Zhu, Xiao-Dong; Tang, Xian-Zhong; Zhao, Huan-Li; Wang, Gui-Bin; Jia, Yue-Qing; Zhu, Shi-Cai; Zhang, Feng-Fang; Liu, Hong-Mei

    2015-01-01

    In this study, we performed a network meta-analysis to compare the outcomes of seven most common surgical procedures to fix DRF, including bridging external fixation, non-bridging external fixation, K-wire fixation, plaster fixation, dorsal plating, volar plating, and dorsal and volar plating. Published studies were retrieved through PubMed, Embase and Cochrane Library databases. The database search terms used were the following keywords and MeSH terms: DRF, bridging external fixation, non-bridging external fixation, K-wire fixation, plaster fixation, dorsal plating, volar plating, and dorsal and volar plating. The network meta-analysis was performed to rank the probabilities of postoperative complication risks for the seven surgical modalities in DRF patients. This network meta-analysis included data obtained from a total of 19 RCTs. Our results revealed that compared to DRF patients treated with bridging external fixation, marked differences in pin-track infection (PTI) rate were found in patients treated with plaster fixation, volar plating, and dorsal and volar plating. Cluster analysis showed that plaster fixation is associated with the lowest probability of postoperative complication in DRF patients. Plaster fixation is associated with the lowest risk for postoperative complications in DRF patients, when compared to six other common DRF surgical methods examined. PMID:26549312

  6. Echocardiographic demonstration of intracardiac glue after endoscopic obturation of gastroesophageal varices.

    PubMed

    Gallet, B; Zemour, G; Saudemont, J P; Renard, P; Hillion, M L; Hiltgen, M

    1995-01-01

    Systemic embolism is an unusual complication of endoscopic obturation of gastroesophageal varices with glue. This report describes a case of cerebral embolism after this procedure. Intracardiac glue within the left atrium was demonstrated by echocardiography. Cardiac fluoroscopy demonstrated an abnormal vessel connecting periesophageal veins with the right upper pulmonary vein. Cardiac surgery was performed. Intracardiac glue was removed and the entering orifice of the abnormal vessel in the right upper pulmonary vein was sutured. To our knowledge, this is the first reported case of intracardiac glue after variceal obturation. Echocardiography is useful in the diagnosis of this rare complication.

  7. 24. Historic American Buildings Survey, W. Jeter Eason Deputy District ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    24. Historic American Buildings Survey, W. Jeter Eason- Deputy District Officer, Photographer November 21, 1936 PLASTER ORNAMENT ON CEILING AND PLASTER CORNICE BACK PARLOR (FRONT PARLOR SIMLAR). - The Hermitage, U.S. Highway 70 North (4580 Rachel's Lane), Nashville, Davidson County, TN

  8. Abstract Sculptures: Wire and Plaster Cloth Creations.

    ERIC Educational Resources Information Center

    Hiller, Peter

    2001-01-01

    Presents a three-dimensional art project for middle-school students in which they create sculptures of plaster cloth and wire. The introduction explains that they learn about Alexander Calder, a master of using wire in art. Discusses how to make the sculptures. (CMK)

  9. Micronucleus formation and DNA damage in buccal epithelial cells of Indian street boys addicted to gasp 'Golden glue'.

    PubMed

    Mondal, Nandan Kumar; Ghosh, Sreenita; Ray, Manas Ranjan

    2011-04-03

    Genotoxicity of glue sniffing/huffing and tobacco use has been examined in 302 street boys (median age 13 years) and 50 age-matched control school boys who were neither tobacco nor glue users. All the street boys were tobacco users. In addition, 155 were addicted to gasp an industrial adhesive popularly known as 'Golden glue'. Micronucleus (MN) frequency was determined as a measure of chromosomal breakage in exfoliated buccal epithelial cells (BECs) and DNA double strand breaks were quantitatively assessed by counting γ-H2AX foci using immunofluorescence microscopy. Micronucleated cell frequencies (MCFs) in BEC of glue non-addicted (only tobacco) and addicted (tobacco plus glue) street boys were 1.87 ± 1.06‰ and 4.04 ± 2.55‰ respectively, which were significantly higher than that of control (0.32 ± 0.11‰, p<0.0001). Similarly, the numbers γ-H2AX foci in nuclei of BEC were 2.3- and 5.2-times more than control in glue non-addicted and addicted street boys respectively (p<0.0001). Spearman's rank correlation revealed a strong positive association between years of glue addiction with MCFs and γ-H2AX foci numbers, and the association between glue addiction and chromosomal and DNA damage remained positive and significant after controlling income, spending on addiction and loss of appetite as potential confounders in multivariate logistic regression analysis. Thus, addiction to tobacco among the street children in India is associated with chromosomal and DNA damage in BECs and the severity of these changes is significantly increased by the habit of sniffing/huffing of industrial glue. Copyright © 2011 Elsevier B.V. All rights reserved.

  10. Soft Matter: Food for Thought

    ERIC Educational Resources Information Center

    Ogborn, Jon

    2004-01-01

    "Soft matter" is a lively current field of research, looking at fundamental theoretical questions about the structure and behaviour of complex forms of matter, and at very practical problems of, for example, improving the performance of glues or the texture of ice cream. Foodstuffs provide an excellent way in to this modern topic, which lies on…

  11. Characteristics, resource utilization and safety profile of patients prescribed with neuropathic pain treatments: a real-world evidence study on general practices in Europe - the role of the lidocaine 5% medicated plaster.

    PubMed

    Katz, Pablo; Pegoraro, Valeria; Liedgens, Hiltrud

    2017-08-01

    To identify characteristics, resource utilization, and safety profile of patients prescribed with lidocaine 5% medicated plaster, pregabalin, gabapentin, amitriptyline and duloxetine when experiencing pain in the real-world setting of general practitioners (GPs) in Europe. Retrospective analysis on real world data from IMS Health Longitudinal Patient Database. Patients with at least one prescription of the drugs of interest during 2014 were selected and those with a non-neuropathic pain-related diagnosis were excluded. Patients' demographic and clinical characteristics, resource utilization data and adverse drug reactions (ADRs) as described in the leaflet were extracted. The association between treatments and ADR occurrence was evaluated applying multivariate logistic models. A total of 70,515 patients were selected from Italy, Germany, the UK, Spain and Belgium. Lidocaine 5% medicated plaster patients were the oldest in Italy, the UK and Spain and the most health impaired in Italy, Spain and Belgium. No relevant differences in the number of co-prescriptions, specialist visits, examinations and hospitalizations were found. Significantly less lidocaine 5% plasters patients experienced ADRs, with odds ratios in favor of lidocaine 5% medicated plasters ranging from 3.41 (p = .036) to 52.33 (p < .001). Evidence from daily clinical practice in GP settings agrees with the findings from more controlled clinical-trial settings, with lidocaine 5% medicated plaster patients showing a better safety profile, but also a comparable level of resource utilization. A possible re-evaluation of the scientific value coming from this retrospective study in building up a diagnostic as well as a therapeutic algorithm is suggested.

  12. Multidisciplinary approach to improve the quality of below-knee plaster casting.

    PubMed

    Williams, John Teudar; Kedrzycki, Marta; Shenava, Yathish

    2018-01-01

    In our trauma unit, we noted a high rate of incorrectly applied below-knee casts for ankle fractures, in some cases requiring reapplication. This caused significant discomfort and inconvenience for patients and additional burden on plaster-room services. Our aim was to improve the quality of plaster casts and reduce the proportion that needed to be reapplied. Our criteria for plaster cast quality were based on the British Orthopaedic Association Casting Standards (2015) and included neutral (plantargrade) ankle position, adequacy of fracture reduction and rate of cast reapplication. Baseline data collection was performed over a 2-month period by two independent reviewers. After distributing findings and presenting to relevant departments, practical casting sessions with orthopaedic technicians were arranged for the multidisciplinary team responsible for casting. This was later supplemented by new casting guidelines in clinical areas and available online. Postintervention data collection was performed over two separate cycles to assess the effect and permanence of intervention. Data from the preintervention period (n=29) showed median ankle position was 32° plantarflexion (PF), with nine (31%) inadequate reductions and six (20%) backslabs reapplied. Following Plan-Do-Study-Act (PDSA) 1, ankle position was significantly improved (median 25° PF), there were fewer inadequate reductions (12%; 2/17) and a lower rate of reapplication (0%; 0/17). After PDSA 2 (n=16), median ankle position was 21° PF, there was one (6%) inadequate reduction and two (12%) reapplications of casts. Following implementation of plaster training sessions for accident and emergency and junior orthopaedic staff, in addition to publishing guidance and new protocol, there has been a sustained improvement in the quality of below-knee backslabs and fewer cast reapplications. These findings justify continuation and expansion of the current programme to include other commonly applied plaster casts.

  13. A Cut-and-Paste Approach to 3D Graphene-Oxide-Based Architectures.

    PubMed

    Luo, Chong; Yeh, Che-Ning; Baltazar, Jesus M Lopez; Tsai, Chao-Lin; Huang, Jiaxing

    2018-04-01

    Properly cut sheets can be converted into complex 3D structures by three basic operations including folding, bending, and pasting to render new functions. Folding and bending are extensively employed in crumpling, origami, and pop-up fabrications for 3D structures. Pasting joins different parts of a material together, and can create new geometries that are fundamentally unattainable by folding and bending. However, it has been much less explored, likely due to limited choice of weldable thin film materials and residue-free glues. Here it is shown that graphene oxide (GO) paper is one such suitable material. Stacked GO sheets can be readily loosened up and even redispersed in water, which upon drying, restack to form solid structures. Therefore, water can be utilized to heal local damage, glue separated pieces, and release internal stress in bent GO papers to fix their shapes. Complex and dynamic 3D GO architectures can thus be fabricated by a cut-and-paste approach, which is also applicable to GO-based hybrid with carbon nanotubes or clay sheets. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  14. Histopathological effects of fibrin glue on penile fracture in a rat model.

    PubMed

    Tasdemir, Cemal; Samdanci, Emine T; Turtay, Muhammet G; Firat, Cemal; Oguzturk, Hakan; Ozdemir, Hulya

    2011-12-01

    To evaluate both histopathological effects and potential clinical application of fibrin glue on the penile cavernosal tissue. Experimental penile fracture was formed by incising from the proximal dorsal side of the penis in 32 Wistar Albino rats. The rats were randomly assigned to four main groups of eight animals each. In the control group, the incision was not repaired and it was left to secondary healing. In the primary repair group, the incision was primarily repaired. In the fibrin glue group, glue was applied only to the incision. In the final group, fibrin glue was applied to the incision following primary repair. Three weeks later, penectomy tissue was examined histopathologically. When the control group was compared with primary repair+fibrin glue group, the differences in cavernous tissue healing with fibrosis and inflammation were statistically significant (p = 0.04 and 0.01, respectively). The primary repair+fibrin glue group, showed the best cavernous healing with fibrosis observed in only one rat. . There was no significant difference between the control group and the other groups according to cavernous tissue healing with fibrosis and inflammation (p = 0.11 and 0.12). Hyperemia was observed in the all groups of rats. Fibrin glue can be used in cavernoseal surgeries due to its adhesive and potentially anti-inflammatory features.

  15. Fibrin glue as agent for sealing corneal and conjunctival wound leaks.

    PubMed

    Scalcione, C; Ortiz-Vaquerizas, D; Said, D G; Dua, H S

    2018-02-01

    PurposeTo describe a novel use of fibrin glue in managing leaking blebs and leaking wounds following trauma or surgery.MethodsInterventional case series.ResultsWe report eight patients, including three where intra-operative or immediate post-penetrating keratoplasty recalcitrant leaks from the graft-host junction and/or openings created by the needle pass, were noted. All three had thin recipient beds in the sector of leak. This was managed by intra-cameral injection of fibrin glue in the affected quadrant. This stopped the leak and allowed the defect to heal. One patient of Descemets-stripping-endothelial-keratoplasty had leak from the surgical wound, which was also sealed with fibrin glue. Two patients with leaking glaucoma-surgery-related blebs were treated with intra-bleb injection of fibrin glue to stop the leak. One patient with a penetrating corneal injury with a metal wire had a brisk leak upon removal of the wire. This was sealed with fibrin glue. Another patient of chemical burn with spontaneous leaks was managed by glue injection in the perforations. Transient rise of intraocular pressure in one patient with a leaking bleb was the only adverse event recorded.ConclusionThis novel adaptation of the application of fibrin glue can help to deal with persistent intra-operative, post-operative and traumatic aqueous and air leaks.

  16. Nonlinear temperature dependence of glue-induced birefringence in polarization maintaining FBG sensors

    NASA Astrophysics Data System (ADS)

    Hopf, Barbara; Koch, Alexander W.; Roths, Johannes

    2016-05-01

    Glue-induced stresses decrease the accuracy of surface-mounted fiber Bragg gratings (FBG). Significant temperature dependent glue-induced birefringence was verified when a thermally cured epoxy-based bonding technique had been used. Determining the peak separation of two azimuthally aligned FBGs in PM fibers combined with a polarization resolved measurement set-up in a temperature range between -30°C and 150°C revealed high glue-induced stresses at low temperatures. Peak separations of about 60 pm and a nonlinear temperature dependence of the glue-induced birefringence due to stress relaxation processes and a visco-elastic behavior of the used adhesive have been shown.

  17. Sculpting Ceramic Heads.

    ERIC Educational Resources Information Center

    Sapiro, Maurice

    1983-01-01

    Clay sculpture is difficult to produce because of the requirements of kiln firing. The problems can be overcome by modeling the original manikin head and making a plaster mold, pressing molding slabs of clay into the plaster mold to form the hollow clay armature, and sculpting on the armature. (IS)

  18. Utilization of ground waste seashells in cement mortars for masonry and plastering.

    PubMed

    Lertwattanaruk, Pusit; Makul, Natt; Siripattarapravat, Chalothorn

    2012-11-30

    In this research, four types of waste seashells, including short-necked clam, green mussel, oyster, and cockle, were investigated experimentally to develop a cement product for masonry and plastering. The parameters studied included water demand, setting time, compressive strength, drying shrinkage and thermal conductivity of the mortars. These properties were compared with those of a control mortar that was made of a conventional Portland cement. The main parameter of this study was the proportion of ground seashells used as cement replacement (5%, 10%, 15%, or 20% by weight). Incorporation of ground seashells resulted in reduced water demand and extended setting times of the mortars, which are advantages for rendering and plastering in hot climates. All mortars containing ground seashells yielded adequate strength, less shrinkage with drying and lower thermal conductivity compared to the conventional cement. The results indicate that ground seashells can be applied as a cement replacement in mortar mixes and may improve the workability of rendering and plastering mortar. Copyright © 2012 Elsevier Ltd. All rights reserved.

  19. Computational modeling of latent-heat-storage in PCM modified interior plaster

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fořt, Jan; Maděra, Jiří; Trník, Anton

    2016-06-08

    The latent heat storage systems represent a promising way for decrease of buildings energy consumption with respect to the sustainable development principles of building industry. The presented paper is focused on the evaluation of the effect of PCM incorporation on thermal performance of cement-lime plasters. For basic characterization of the developed materials, matrix density, bulk density, and total open porosity are measured. Thermal conductivity is accessed by transient impulse method. DSC analysis is used for the identification of phase change temperature during the heating and cooling process. Using DSC data, the temperature dependent specific heat capacity is calculated. On themore » basis of the experiments performed, the supposed improvement of the energy efficiency of characteristic building envelope system where the designed plasters are likely to be used is evaluated by a computational analysis. Obtained experimental and computational results show a potential of PCM modified plasters for improvement of thermal stability of buildings and moderation of interior climate.« less

  20. [Experimental study on repair of the defect of the pars interarticularis in rat with bone morphogenetic protein and fibrin glue].

    PubMed

    Nakamura, T

    1992-07-01

    The possibility of repairing the defect of the pars interarticularis (pars defect) with Bone Morphogenetic Protein (BMP) and fibrin glue was studied. The pars defect established in the 5th lumbar vertebra of Wistar rat was treated with surgical implantation of a composite consisting of BMP, fibrin glue and autologous cancellous bone. At 3, 6, 9 and 12 weeks after implantation, the osteoinductive activity in the pars defect was observed histologically and compared with that of other composite implants such as BMP with fibrin glue, autologous cancellous bone alone and autologous cancellous bone with fibrin glue. Although perfect bone fusion was not obtained with any of the composites employed, a significant increase in bone formation was seen in a composite of BMP, fibrin glue and autologous cancellous bone (p less than 0.01) as compared with that seen in the others. Consequently, implantation of BMP and fibrin glue combined with some biomaterials which support osteo-induction of BMP and stabilize the pars defect might be successfully applied to repair the pars defect.

  1. Creation of 3D Multi-Body Orthodontic Models by Using Independent Imaging Sensors

    PubMed Central

    Barone, Sandro; Paoli, Alessandro; Razionale, Armando Viviano

    2013-01-01

    In the field of dental health care, plaster models combined with 2D radiographs are widely used in clinical practice for orthodontic diagnoses. However, complex malocclusions can be better analyzed by exploiting 3D digital dental models, which allow virtual simulations and treatment planning processes. In this paper, dental data captured by independent imaging sensors are fused to create multi-body orthodontic models composed of teeth, oral soft tissues and alveolar bone structures. The methodology is based on integrating Cone-Beam Computed Tomography (CBCT) and surface structured light scanning. The optical scanner is used to reconstruct tooth crowns and soft tissues (visible surfaces) through the digitalization of both patients' mouth impressions and plaster casts. These data are also used to guide the segmentation of internal dental tissues by processing CBCT data sets. The 3D individual dental tissues obtained by the optical scanner and the CBCT sensor are fused within multi-body orthodontic models without human supervisions to identify target anatomical structures. The final multi-body models represent valuable virtual platforms to clinical diagnostic and treatment planning. PMID:23385416

  2. Creation of 3D multi-body orthodontic models by using independent imaging sensors.

    PubMed

    Barone, Sandro; Paoli, Alessandro; Razionale, Armando Viviano

    2013-02-05

    In the field of dental health care, plaster models combined with 2D radiographs are widely used in clinical practice for orthodontic diagnoses. However, complex malocclusions can be better analyzed by exploiting 3D digital dental models, which allow virtual simulations and treatment planning processes. In this paper, dental data captured by independent imaging sensors are fused to create multi-body orthodontic models composed of teeth, oral soft tissues and alveolar bone structures. The methodology is based on integrating Cone-Beam Computed Tomography (CBCT) and surface structured light scanning. The optical scanner is used to reconstruct tooth crowns and soft tissues (visible surfaces) through the digitalization of both patients' mouth impressions and plaster casts. These data are also used to guide the segmentation of internal dental tissues by processing CBCT data sets. The 3D individual dental tissues obtained by the optical scanner and the CBCT sensor are fused within multi-body orthodontic models without human supervisions to identify target anatomical structures. The final multi-body models represent valuable virtual platforms to clinical diagnostic and treatment planning.

  3. Atomic Oxygen Cleaning of Unpainted Plaster Sculptures

    NASA Technical Reports Server (NTRS)

    Banks, Bruce A.; Miller, Sharon K.

    2017-01-01

    Atomic oxygen erosion of polymers has been found to be a threat to spacecraft in low Earth orbit. As a result ground facilities have been developed to identify coatings to protect polymers such as used for solar array blankets. As a result of extensive laboratory testing, it was discovered that soot and other organic contamination on paintings could be readily removed by atomic oxygen interactions with minimal damage to the artwork. No method, other than dusting, has been found to be effective in the cleaning of unpainted plaster sculptures This presentation discusses the atomic oxygen interaction processes and how effective they are for cleaning soot damaged unpainted plaster sculptures.

  4. Fibrin glue as a hemostatic agent in hepatic and splenic trauma.

    PubMed

    Ochsner, M G; Maniscalco-Theberge, M E; Champion, H R

    1990-07-01

    Fibrin glue is a biologic hemostatic agent that coagulates and seals upon application. It is made by combining human fibrinogen concentrate with standard thrombin solutions containing calcium. Similar to epoxy glue, the two components are applied simultaneously in equal volumes resulting in an almost instantaneous formation of a coagulum. Fibrinogen concentrate is prepared in the blood bank from single donor plasma. Fibrin glue can be applied topically or injected into the parenchyma of solid organs. Twenty-six patients sustained hepatic or splenic trauma from May through August 1989--17 liver and nine splenic injuries. The glue was effective after one application in 21 patients and after a second in five. Hemostasis was achieved despite coagulopathy and thrombocytopenia in eight patients. There were no re-explorations for bleeding, and nine complications occurred in six patients. Our experience suggests fibrin glue is an effective, underutilized adjunctive hemostatic agent in trauma.

  5. Adhesion modulation using glue droplet spreading in spider capture silk

    PubMed Central

    Zhang, Ci; Blackledge, Todd A.

    2017-01-01

    Orb web spiders use sticky capture spiral silk to retain prey in webs. Capture spiral silk is composed of an axial fibre of flagelliform silk covered with glue droplets that are arranged in a beads-on-a-string morphology that allows multiple droplets to simultaneously extend and resist pull off. Previous studies showed that the adhesion of capture silk is responsive to environmental humidity, increasing up to an optimum humidity that varied among different spider species. The maximum adhesion was hypothesized to occur when the viscoelasticity of the glue optimized contributions from glue spreading and bulk cohesion. In this study, we show how glue droplet shape during peeling contributes significantly to capture silk adhesion. Both overspreading and underspreading of glue droplets reduces adhesion through changes in crack propagation and failure regime. Understanding the mechanism of stimuli-responsive adhesion of spider capture silk will lead to new designs for smarter adhesives. PMID:28490605

  6. Adhesion modulation using glue droplet spreading in spider capture silk.

    PubMed

    Amarpuri, Gaurav; Zhang, Ci; Blackledge, Todd A; Dhinojwala, Ali

    2017-05-01

    Orb web spiders use sticky capture spiral silk to retain prey in webs. Capture spiral silk is composed of an axial fibre of flagelliform silk covered with glue droplets that are arranged in a beads-on-a-string morphology that allows multiple droplets to simultaneously extend and resist pull off. Previous studies showed that the adhesion of capture silk is responsive to environmental humidity, increasing up to an optimum humidity that varied among different spider species. The maximum adhesion was hypothesized to occur when the viscoelasticity of the glue optimized contributions from glue spreading and bulk cohesion. In this study, we show how glue droplet shape during peeling contributes significantly to capture silk adhesion. Both overspreading and underspreading of glue droplets reduces adhesion through changes in crack propagation and failure regime. Understanding the mechanism of stimuli-responsive adhesion of spider capture silk will lead to new designs for smarter adhesives. © 2017 The Author(s).

  7. Clipboard

    ERIC Educational Resources Information Center

    Timmons, Virginia

    1978-01-01

    For the teacher with a limited art materials budget plaster provides a "best buy" in terms of the variety of art projects possible and relative cost. With plaster, the student can cast blocks for printmaking, carving, and assemblage and use it, in combination with other materials, in crafts projects. Describes different kinds of plaster…

  8. Fragmentation, Cost and Environmental Effects of Plaster Stemming Method for Blasting at A Basalt Quarry

    NASA Astrophysics Data System (ADS)

    Cevizci, Halim

    2014-10-01

    In this study, the plaster stemming application for blasting at a basalt quarry is studied. Drill cuttings are generally used in open pits and quarries as the most common stemming material since these are most readily available at blast sites. However, dry drill cuttings eject very easily from blastholes without offering much resistance to blast energy. The plaster stemming method has been found to be better than the drill cuttings stemming method due to increased confinement inside the hole and better utilization of blast explosive energy in the rock. The main advantage of the new stemming method is the reduction in the cost of blasting. At a basalt quarry, blasting costs per unit volume of rock were reduced to 15% by increasing burden and spacing distances. In addition, better fragmentation was obtained by using the plaster stemming method. Blast trials showed that plaster stemming produced finer material. In the same blast tests, +30 cm size fragments were reduced to 47.3% of the total, compared to 32.6% in the conventional method of drill cuttings stemming. With this method of stemming, vibration and air shock values increased slightly due to more blast energy being available for rock breakage but generally these increased values were small and stayed under the permitted limit for blast damage criteria unless measuring distance is too close.

  9. Accuracy of Bolton analysis measured in laser scanned digital models compared with plaster models (gold standard) and cone-beam computer tomography images.

    PubMed

    Kim, Jooseong; Lagravére, Manuel O

    2016-01-01

    The aim of this study was to compare the accuracy of Bolton analysis obtained from digital models scanned with the Ortho Insight three-dimensional (3D) laser scanner system to those obtained from cone-beam computed tomography (CBCT) images and traditional plaster models. CBCT scans and plaster models were obtained from 50 patients. Plaster models were scanned using the Ortho Insight 3D laser scanner; Bolton ratios were calculated with its software. CBCT scans were imported and analyzed using AVIZO software. Plaster models were measured with a digital caliper. Data were analyzed with descriptive statistics and the intraclass correlation coefficient (ICC). Anterior and overall Bolton ratios obtained by the three different modalities exhibited excellent agreement (> 0.970). The mean differences between the scanned digital models and physical models and between the CBCT images and scanned digital models for overall Bolton ratios were 0.41 ± 0.305% and 0.45 ± 0.456%, respectively; for anterior Bolton ratios, 0.59 ± 0.520% and 1.01 ± 0.780%, respectively. ICC results showed that intraexaminer error reliability was generally excellent (> 0.858 for all three diagnostic modalities), with < 1.45% discrepancy in the Bolton analysis. Laser scanned digital models are highly accurate compared to physical models and CBCT scans for assessing the spatial relationships of dental arches for orthodontic diagnosis.

  10. Double Coaxial Microcatheter Technique for Glue Embolization of Renal Arteriovenous Malformations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Uchikawa, Yoko, E-mail: jauchikawa@gmail.com; Mori, Kensaku, E-mail: moriken@md.tsukuba.ac.jp; Shiigai, Masanari, E-mail: m-41gai@yahoo.co.jp

    PurposeTo demonstrate the technical benefit of the double coaxial microcatheter technique for embolization of renal arteriovenous malformations (AVMs) with n-butyl cyanoacrylate and iodized oil (glue).Materials and MethodsSix consecutive patients (1 man and 5 women; mean age 61 years; range 44–77 years) with renal AVMs were included. Five patients had hematuria, and one had a risk of heart failure due to a large intrarenal arteriovenous shunt. All patients underwent transarterial embolization using glue and the double coaxial microcatheter technique with outer 2.6F and inner 1.9F microcatheters. After glue injection, the inner microcatheter was retracted, while the outer microcatheter was retained. We assessed themore » complications and clinical outcomes of this technique.ResultsTechnical success was achieved in all patients. In 9 sessions, 34 feeding arteries were embolized with glue using the double coaxial microcatheter technique, 1 was embolized with glue using a single microcatheter, and 2 were embolized with coils. The double coaxial microcatheter technique was useful for selecting small tortuous feeding arteries, preventing glue reflux to the proximal arteries, and approaching multiple feeding arteries without complete retraction of the microcatheters. As a minor complication, glue migrated into the venous system in four patients without any sequelae. In all patients, favorable clinical outcomes, including hematuria cessation in five patients and improvement of the large intrarenal arteriovenous shunt in one patient, were obtained without deterioration of renal function.ConclusionGlue embolization with the double coaxial microcatheter technique was useful for treating renal AVMs with multiple tortuous feeding arteries.« less

  11. Pro-osteogenic effects of fibrin glue in treatment of avascular necrosis of the femoral head in vivo by hepatocyte growth factor-transgenic mesenchymal stem cells

    PubMed Central

    2014-01-01

    Background Autologous transplantation of modified mesenchymal stem cells (MSCs) is a promising candidate for the treatment of the refractory clinical disease, avascular necrosis of the femoral head (ANFH). Our previous attempts by compounding MSCs with medical fibrin glue to treat ANFH in animal model have achieved excellent effects. However, the underlying molecular mechanism is unclear, especially on the transgenic gene expression. Methods Rabbit MSCs were isolated and compounded with fibrin glue. Following degrading of fibrin glue, proliferation, viability, expression of transgenic hepatocyte growth factor gene as well as osteogenic differentiation of MSCs were evaluated together with that of uncompounded MSCs. Fibrin glue-compounded MSCs were transplanted into the lesion of ANFH model, and the therapeutic efficacy was compared with uncompounded MSCs. One-Way ANOVA was used to determine the statistical significance among treatment groups. Results Fibrin glue compounding will not affect molecular activities of MSCs, including hepatocyte growth factor (HGF) secretion, cell proliferation and viability, and osteogenic differentiation in vitro. When applying fibrin glue-compounded MSCs for the therapy of ANFH in vivo, fibrin glue functioned as a drug delivery system and provided a sustaining microenvironment for MSCs which helped the relatively long-term secretion of HGF in the femoral head lesion and resulted in improved therapeutic efficacy when compared with uncompounded MSCs as indicated by hematoxylin-eosin staining and immunohistochemistry of osteocalcin, CD105 and HGF. Conclusion Transplantation of fibrin glue-compounding MSCs is a promising novel method for ANFH therapy. PMID:24885252

  12. Cyanoacrylate medical glue application in intervertebral disc annulus defect repair: Mechanical and biocompatible evaluation.

    PubMed

    Kang, Ran; Li, Haisheng; Lysdahl, Helle; Quang Svend Le, Dang; Chen, Menglin; Xie, Lin; Bünger, Cody

    2017-01-01

    In an attempt to find an ideal closure method during annulus defect repair, we evaluate the use of medical glue by mechanical and biocompatible test. Cyanoacrylate medical glue was applied together with a multilayer microfiber/nanofiber polycaprolactone scaffold and suture in annulus repair. Continuous axial loading and fatigue mechanical test was performed. Furthermore, the in vitro response of mesenchymal stem cell (MSC) to the glue was evaluated by cell viability assay. The in vivo response of annulus tissue to the glue and scaffold was also studied in porcine lumbar spine; histological sections were evaluated after 3 months. Cyanoacrylate glue significantly improved the closure effect in the experimental group with failure load 2825.7 ± 941.6 N, compared to 774.1 ± 281.3 N in the control group without glue application (p < 0.01). The experimental group also withstood the fatigue test. No toxic effect was observed by in vitro cell culture and in vivo implantation. On the basis of this initial evaluation, the use of cyanoacrylate medical glue improves closure effect with no toxicity in annulus defect repair. This method of annulus repair merits further effectiveness study in vivo. © 2015 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 105B: 14-20, 2017. © 2015 Wiley Periodicals, Inc.

  13. Plaster People...A La George Segal.

    ERIC Educational Resources Information Center

    Boulay, Michele

    2003-01-01

    Describes an art project used with eleventh- and twelfth-grade students in which they created plaster self-portraits inspired by the work of George Segal. Includes directions for the casting and lists the art materials needed for the lesson. Explains that the project requires half a semester to complete. (CMK)

  14. Effectiveness of a new gelatin sealant system for dural closure.

    PubMed

    Kawai, Hisashi; Nakagawa, Ichiro; Nishimura, Fumihiko; Motoyama, Yasushi; Park, Young-Su; Nakamura, Mitsutoshi; Nakase, Hiroyuki; Suzuki, Shuko; Ikada, Yoshito

    2014-10-01

    Watertight dural closure is imperative after neurosurgical procedures because inadequately treated leakage of cerebrospinal fluid (CSF) can have serious consequences. In this study, the authors test the use of a new gelatin glue as a dural sealant in in vitro and in vivo canine models of transdural CSF leakage. The in vitro model was sutured semicircles of canine dura mater and artificial dural substitute. The sutures were sealed with gelatin glue (n  =  20), fibrin glue (n  =  20), or a polyethylene glycol (PEG)-based hydrogel sealant (n  =  20). Each sample was set in a device to measure water pressure, and pressure was increased until leakage occurred. Bonding strength was subjectively evaluated. The in vivo model was dogs who underwent dural excision and received either no sealant (control group; n  =  5) or gelatin glue sealant (n  =  5) before dural closure. Twenty-eight days post-surgery, the maximum intracranial pressure was measured at the cisterna magna using Valsalva maneuver and tissue adhesion was evaluated. The water pressure at which leakage occurred in the in vitro model was higher with gelatin glue (76·5 ± 39·8 mmHg) than with fibrin glue (38·3 ± 27·4 mmHg, P < 0·001) or the PEG-based hydrogel sealant (46·3 ± 20·9 mmHg, P  =  0·007). Bonding strength was higher for the gelatin glue than fibrin glue (P < 0·001) or PEG-based hydrogel sealant (P  =  0·001). The maximum intracranial pressure in the in vivo model was higher for the gelatin glue group (59·0 ± 2·2 mmHg) than the control group (13·8 ± 4·0 mmHg, P < 0·001). Tissue adhesion was lower for the gelatin glue group than the control group (P  =  0·005). The new gelatin glue provides an effective watertight closure when used as an adjunct to sutured dural repair.

  15. Detector development for Jefferson Lab's 12GeV Upgrade

    DOE PAGES

    Qiang, Yi

    2015-05-01

    Jefferson Lab will soon finish its highly anticipated 12 GeV Upgrade. With doubled maximum energy, Jefferson Lab’s Continuous Electron Beam Accelerator Facility (CEBAF) will enable a new experimental program with substantial discovery potential, addressing important topics in nuclear, hadronic and electroweak physics. In order to take full advantage of the high energy, high luminosity beam, new detectors are being developed, designed and constructed to fit the needs of different physics topics. The paper will give an overview of various new detector technologies to be used for 12 GeV experiments. It will then focus on the development of two solenoid-based spectrometers,more » the GlueX and SoLID spectrometers. The GlueX experiment in Hall D will study the complex properties of gluons through exotic hybrid meson spectroscopy. The GlueX spectrometer, a hermetic detector package designed for spectroscopy and the associated partial wave analysis, is currently in the final stage of construction. Hall A, on the other hand, is developing the SoLID spectrometer to capture the 3D image of the nucleon from semi-inclusive processes and to study the intrinsic properties of quarks through mirror symmetry breaking. Such a spectrometer will have the capability to handle very high event rates while still maintaining a large acceptance in the forward region.« less

  16. Soft matter: food for thought

    NASA Astrophysics Data System (ADS)

    Ogborn, Jon

    2004-01-01

    'Soft matter' is a lively current field of research, looking at fundamental theoretical questions about the structure and behaviour of complex forms of matter, and at very practical problems of, for example, improving the performance of glues or the texture of ice cream. Foodstuffs provide an excellent way in to this modern topic, which lies on the boundary between physics and chemistry.

  17. Chronic glue sniffing with transient central hypothyroidism and hypergonadotropism.

    PubMed

    Chen, Hua-Fen; Chen, Shwe-Winn; Chen, Peter; Su, Mei-Chin; See, Ting-Ting; Lee, Hsin-Yu

    2003-12-01

    Neuropsychiatric, gastrointestinal and muscular disorders associated with glue sniffing have been widely reported, but endocrinologic abnormalities of glue exposure are rarely mentioned in the literature. We report a 26-year old male patient, a chronic glue sniffer, who presented with weakness of both lower limbs. On physical examination, he had reduced muscle strength of his 4 limbs, especially in his lower limbs. Laboratory examination revealed hypokalemia with hyperchloremic metabolic acidosis. His thyroid function showed low TSH, T4, T3, free T4 and reverse T3 level. Other pituitary functions were normal apart from high FSH and LH level. TSH response to TRH stimulation was normal, but there was impaired T3 response to TRH. MRI of pituitary showed no significant changes. He continued glue sniffing after discharge. He repeatedly came to our hospital for recurrent hypokalemic paralysis. His serum T4 and free T4 level were low when he had certain amount of glue sniffing and it returned to normal after he stopped sniffing or sniffed less amount of glue. His serum T3 concentrations were normal most of the times thereafter. His FSH and LH level were persistently elevated, even after he did not sniff glue for 2 weeks. Low free T4, TSH and reverse T3 level associated with glue sniffing in our patient were compatible with central hypothyroidism. Toluene, a neurotoxic organic solvent, is present in glues. Being highly lipophilic, it can easily enter and is retained within the lipid-rich nervous system after being inhaled. Like other organic solvents, toluene has been shown to affect dopaminergic and adrenergic turnover within various parts of the brain. The effects on these neurotransmitters could lead to abnormal secretion of pituitary hormones resulting in transient central hypothyroidism and abnormal gonadotropin levels. Long-term harmful effect of central hypothyroidism and chronic influence of abnormal gonadotropins to reproduction function needs further observation.

  18. Mussel mimetic tissue adhesive for fetal membrane repair: initial in vivo investigation in rabbits.

    PubMed

    Kivelio, A; Dekoninck, P; Perrini, M; Brubaker, C E; Messersmith, P B; Mazza, E; Deprest, J; Zimmermann, R; Ehrbar, M; Ochsenbein-Koelble, N

    2013-12-01

    Iatrogenic preterm prelabour rupture of fetal membranes (iPPROM) remains the main complication after invasive interventions into the intrauterine cavity. The aim of this study was to evaluate the sealing capability and tissue interaction of mussel-mimetic tissue adhesive (mussel glue) in comparison to fibrin glue on punctured fetal membranes in vivo. A mid-gestational rabbit model was used for testing the materials. The fetal sacs of pregnant rabbits at day 23 were randomly assigned into experimental groups: unoperated (negative control), unclosed puncture (positive control), commercially available fibrin glue (FG) with decellularized amnion scaffold (DAM), mussel glue (MG) with DAM, or mussel glue alone. Evaluation was done at term (30 days' gestation) assessing fetal survival, fetal membrane integrity and histology of the membranes. Fetal survival was not significantly lower in any of the treatment groups compared to the negative control. All plugging materials could be found at the end of the pregnancy and no adverse effects on the fetus or the pregnant does could be observed. Sac integrity was higher in all treatment groups compared to the positive control group but significant only in the FG+DAM group. Cellular infiltration could be seen in fibrin glue and DAM in contrast to mussel glue which was only tightly adhering to the surrounding tissue. These cells were mostly of mesenchymal phenotype staining positive for vimentin. CD68 positive macrophages were found clustered around all the plugging materials, but their numbers were only significantly increased for the mussel glue alone group compared to negative controls. Mussel glues performance in sealing fetal membranes in the rabbit model was comparable to that of fibrin glue. Taking into account its other favorable properties, it is a noteworthy candidate for a clinically applicable fetal membrane sealant. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  19. Robust cross-links in molluscan adhesive gels: Testing for contributions from hydrophobic and electrostatic interactions

    PubMed Central

    Smith, A.M.; Robinson, T. M.; Salt, M. D.; Hamilton, K. S.; Silvia, B. E.; Blasiak, R.

    2009-01-01

    The cross-linking interactions that provide cohesive strength to molluscan adhesive gels were investigated. Metal-based interactions have been shown to play an important role in the glue of the slug Arion subfuscus (Draparnaud), but other types of interactions may also contribute to the glue's strength and their role has not been investigated. This study shows that treatments that normally disrupt hydrophobic or electrostatic interactions have little to no effect on the slug glue. High salt concentrations and non-ionic detergent do not affect the solubility of the proteins in the glue or the ability of the glue proteins to stiffen gels. In contrast, metal chelation markedly disrupts the gel. Experiments with gel filtration chromatography identify a 40 kDa protein that is a central component of the cross-links in the glue. This 40 kDa protein forms robust macromolecular aggregations that are stable even in the presence of high concentrations of salt, non-ionic detergent, urea or metal chelators. Metal chelation during glue secretion, however, may block some of these cross-links. Such robust, non-specific interactions in an aqueous environment are highly unusual for hydrogels and reflect an intriguing cross-linking mechanism. PMID:18952190

  20. A Comparative Study of the Effect of Fibrin Glue versus Sutures on Clinical Outcome in Patients Undergoing Pterygium Excision and Conjunctival Autografts

    PubMed Central

    Cha, Dong Min; Kim, Kyeong Hwan; Choi, Hyuk Jin; Wee, Won Ryang

    2012-01-01

    Purpose To compare the effect of using fibrin glue or 10-0 nylon sutures on the clinical outcome of patients undergoing pterygium excision and conjunctival autografting. Methods We retrospectively reviewed the medical records of 52 eyes from 46 patients who underwent pterygium excision and conjunctival autografting and were followed up for more than 3 months. The operation duration, postoperative inflammation, complications, and recurrence rates were compared between groups of 20 patients (22 eyes) for whom fibrin glue was used (fibrin glue group) and 26 patients (30 eyes) for whom suturing was performed with 10-0 nylon (suture group) in pterygium excision and conjunctival autografting. Results The operation duration was 27.71 (5.22) minutes in the fibrin glue group and 43.30 (8.18) minutes in the suture group (p = 0.000). Seven days after the operation, the fibrin glue group showed milder conjunctival inflammation than the suture group (p = 0.000). Postoperative complications and corneal recurrence rates were not statistically different between the two groups. Conclusions The use of fibrin glue in pterygium excision with conjunctival autografting is likely to be a more effective, safer procedure than suturing. PMID:23204794

  1. Dynamics of spider glue adhesion: effect of surface energy and contact area

    NASA Astrophysics Data System (ADS)

    Amarpuri, Gaurav; Chen, Yizhou; Blackledge, Todd; Dhinojwala, Ali

    Spider glue is a unique biological adhesive which is humidity responsive such that the adhesion continues to increase upto 100% relative humidity (RH) for some species. This is unlike synthetic adhesives that significantly drop in adhesion with an increase in humidity. However, most of adhesion data reported in literature have used clean hydrophilic glass substrate, unlike the hydrophobic, and charged insect cuticle surface that adheres to spider glue in nature. Previously, we have reported that the spider glue viscosity changes over five orders of magnitude with humidity. Here, we vary the surface energy and surface charge of the substrate to test the change in Larnioides cornutus spider glue adhesion with humidity. We find that an increase in both surface energy and surface charge density increases the droplet spreading and there exists an optimum droplet contact area where adhesion is maximized. Moreover, spider glue droplets act as reusable adhesive for low energy hydrophobic surface at the optimum humidity. These results explain why certain prey are caught more efficiently by spiders in their habitat. The mechanism by which spider species tune its glue adhesion for local prey capture can inspire new generation smart adhesives.

  2. Robust cross-links in molluscan adhesive gels: testing for contributions from hydrophobic and electrostatic interactions.

    PubMed

    Smith, A M; Robinson, T M; Salt, M D; Hamilton, K S; Silvia, B E; Blasiak, R

    2009-02-01

    The cross-linking interactions that provide cohesive strength to molluscan adhesive gels were investigated. Metal-based interactions have been shown to play an important role in the glue of the slug Arion subfuscus (Draparnaud), but other types of interactions may also contribute to the glue's strength and their role has not been investigated. This study shows that treatments that normally disrupt hydrophobic or electrostatic interactions have little to no effect on the slug glue. High salt concentrations and non-ionic detergent do not affect the solubility of the proteins in the glue or the ability of the glue proteins to stiffen gels. In contrast, metal chelation markedly disrupts the gel. Experiments with gel filtration chromatography identify a 40 kDa protein that is a central component of the cross-links in the glue. This 40 kDa protein forms robust macromolecular aggregations that are stable even in the presence of high concentrations of salt, non-ionic detergent, urea or metal chelators. Metal chelation during glue secretion, however, may block some of these cross-links. Such robust, non-specific interactions in an aqueous environment are highly unusual for hydrogels and reflect an intriguing cross-linking mechanism.

  3. Molecular mechanism for adhesion in humid conditions - lessons from spider glue

    NASA Astrophysics Data System (ADS)

    Amarpuri, Gaurav; Singla, Saranshu; Dhopatkar, Nishad; Blackledge, Todd; Dhinojwal, Ali

    Adhesion in humid conditions is a fundamental challenge for both natural and synthetic adhesives. Water lubricates the interface between the adhesive and the substrate resulting in an interfacial failure at high humidity. Yet, glue from most spider species fail cohesively at high humidity, and the spider species from wet habitat show an increase in adhesion with humidity. We use tensile testing, microscopy and surface sensitive spectroscopy techniques to probe the mechanism of spider glue adhesion under high humidity. Humidity responsive structural changes in the glue structure are observed both at the interface and in bulk. However, the humidity responsiveness is lost after washing the water soluble low molecular weight molecules (LMM) from the glue. Many natural systems display a functional response to their environment, but spider glue's humidity responsiveness is a novel adaptation that makes the glue stickiest in each species' preferred habitat. This tuning is achieved by a combination of proteins and hygroscopic LMM that respond to humidity in a unique way. We therefore anticipate that manipulation of polymer-LMM interaction can provide a simple mechanism to design humidity responsive smart adhesives. We acknowledge support from National Science Foundation Grant IOS-1257719.

  4. Optimization of performance parameters for large area silicon photomultipliers for use in the GlueX experiment

    NASA Astrophysics Data System (ADS)

    Janzen, Kathryn Louise

    Largely because of their resistance to magnetic fields, silicon photomultipliers (SiPMs) are being considered as the readout for the GlueX Barrel Calorimeter, a key component of the GlueX detector located immediately inside a 2.2 T superconducting solenoid. SiPMs with active area 1 x 1 mm2 have been investigated for use in other experiments, but detectors with larger active areas are required for the GlueX BCAL. This puts the GlueX collaboration in the unique position of being pioneers in the use of this frontend detection revolution by driving the technology for larger area sensors. SensL, a photonics research and development company in Ireland, has been collaborating with the University of Regina GlueX group to develop prototype large area SiPMs comprising 16 - 3x3 mm2 cells assembled in a close-packed matrix. Performance parameters of individual SensL 1x1 mm2 and 3x3 mm2 SiPMs along with prototype SensL SiPM arrays are tested, including current versus voltage characteristics, photon detection efficiency, and gain uniformity, in an effort to determine the suitability of these detectors to the GlueX BCAL readout.

  5. Glue Sniffers with Special Needs.

    ERIC Educational Resources Information Center

    O'Connor, Denis

    1987-01-01

    Glue sniffing and solvent misuse have seriously affected children and teenagers throughout the United Kingdom. This article discusses glue sniffing in terms of prevalence, association with disability, physical and psychological effects, signs and symptoms, counseling for sniffers, and successful interventions including an approach using videotape…

  6. A general contact mechanical formulation of multilayered structures and its application to deconvolute thickness/mechanical properties of glue used in surface force apparatus.

    PubMed

    Math, Souvik; Horn, Roger; Jayaram, Vikram; Biswas, Sanjay Kumar

    2007-04-15

    Currently data obtained from surface force apparatus experiments are convoluted with the mechanical response of glue of unknown thickness, used to bond mica sheets to the substrates. This paper describes a formulation to precisely deconvolute out the forces between the mica sheets by determining the thickness of glue, knowing the mechanical properties of the glue. The formulation consists of a general solution based on the noniterative Hankel transform of the Laplace equation. The generality is achieved by treating all the layers except the one in contact as an effective lumped system consisting of a set of springs in series, where each spring represents a layer. The solution is validated by nanoindentation of trilayer systems consisting of layers with widely diverse mechanical properties, some differing from each other by three orders of magnitude. SFA experiments are done with carefully metered slabs of glue. The proposed method is validated by comparing the actual glue thicknesses with those determined using the present analysis.

  7. Use of cyanoacrylate glue for temporary tarsorrhaphy in children.

    PubMed

    Trivedi, Dipti; McCalla, Maureen; Squires, Zoe; Parulekar, Manoj

    2014-01-01

    Congenital anophthalmia and postenucleation socket contracture are difficult conditions that require serial socket expansion with the use of hydrogel expanders and custom-made conformers along with temporary tarsorrhaphy. The authors undertook a part prospective case review of all children undergoing temporary tarsorrhaphy using cyanoacrylate glue over a 3-year period at a tertiary specialist children's hospital. They report a series of 7 children undergoing temporary tarsorrhaphy with cyanoacrylate glue instead of the conventional suturing technique. Indications were socket expansion (n = 4), fornix deepening (n = 2), prosthesis reposition, and prolapsed conjunctiva following enucleation (n = 1).The age range was 3 weeks to 14 years (mean, 2.7 years). The glue tarsorrhaphy lasted between 0.5 and 13 weeks (mean, 4.5 weeks). There were no adverse outcomes, and the glue tarsorrhaphy was tolerated well in all cases, with relative ease of reapplication of glue in clinic. Their study demonstrates that this technique allows quick and efficient temporary tarsorrhaphy with relative ease of reapplication in a clinic setting, avoiding the need for multiple general anesthetics.

  8. Fibrin glue as a protective tool for microanastomoses in limb reconstructive surgery.

    PubMed

    Langer, Stefan; Schildhauer, Thomas A; Dudda, Marcel; Sauber, Jeannine; Spindler, Nick

    2015-01-01

    Fibrin glue becomes a more and more routinely used tool for stabilization of microanastomoses and nerve repair. This paper summarizes the technical properties and advantages of its use in a wide variety of microsurgical contexts, and includes an exemplary limb reconstructive case. A total of 131 patients who had undergone elective and emergency microsurgery mainly of the limbs were retrospectively analyzed, as was the use of free flaps. The use of fibrin glue allows for proper positioning of anastomoses and repaired nerves. No torsion of the pedicle could be seen. The flap survival rated >94%. The fibrin glue could stay in place in >99%. In the rare case of revision, the fibrin glue could easily be removed without damaging the region of the microanastomosis. Fibrin glue should not be used to repair insufficient, i.e., leaking anastomoses, but it does protect the site of anastomosis from tissue and fluid pressure. It prevents the pedickle from torsion and its use facilitates relocation of the microanastomoses in cases of revision surgery.

  9. Accuracy of Bolton analysis measured in laser scanned digital models compared with plaster models (gold standard) and cone-beam computer tomography images

    PubMed Central

    Kim, Jooseong

    2016-01-01

    Objective The aim of this study was to compare the accuracy of Bolton analysis obtained from digital models scanned with the Ortho Insight three-dimensional (3D) laser scanner system to those obtained from cone-beam computed tomography (CBCT) images and traditional plaster models. Methods CBCT scans and plaster models were obtained from 50 patients. Plaster models were scanned using the Ortho Insight 3D laser scanner; Bolton ratios were calculated with its software. CBCT scans were imported and analyzed using AVIZO software. Plaster models were measured with a digital caliper. Data were analyzed with descriptive statistics and the intraclass correlation coefficient (ICC). Results Anterior and overall Bolton ratios obtained by the three different modalities exhibited excellent agreement (> 0.970). The mean differences between the scanned digital models and physical models and between the CBCT images and scanned digital models for overall Bolton ratios were 0.41 ± 0.305% and 0.45 ± 0.456%, respectively; for anterior Bolton ratios, 0.59 ± 0.520% and 1.01 ± 0.780%, respectively. ICC results showed that intraexaminer error reliability was generally excellent (> 0.858 for all three diagnostic modalities), with < 1.45% discrepancy in the Bolton analysis. Conclusions Laser scanned digital models are highly accurate compared to physical models and CBCT scans for assessing the spatial relationships of dental arches for orthodontic diagnosis. PMID:26877978

  10. [Contribution of computer-aided design for the conception of custom-made implants in Pectus Excavatum surgical treatment. Experience of the Nantes plastic surgery unit].

    PubMed

    Tilliet Le Dentu, H; Lancien, U; Sellal, O; Duteille, F; Perrot, P

    2018-02-01

    Pectus excavatum is the most common congenital chest malformation and is a common reason for consultation in plastic surgery. Our attitude is most often a filling of the depression with a custom-made silicone prosthesis. The objective of this work was to evaluate the interest of computer-aided design (CAD) of implants compared to the conventional plaster molds method. We have collected all the cases of custom-made silicone implants to treat funnel chests in our plastic surgery department. The quality of the results was evaluated by the patient, and in a blind manner by the surgical team using photographs and standardized surveys. The pre-operative delays, the operating time and length of hospital stays, the number of surgical recoveries, and the post-operative surgical outcomes were recorded. Between 1990 and 2016, we designed 29 silicone thoracic implants in our department. Before 2012, implants were made from plaster chest molds (n=13). After this date, implants were designed by CAD (n=16). Patients rated their results as "good" or "excellent" in 77% and 86% of cases respectively in the plaster and CAD groups. The surgical team's ratings for CAD implant reconstructions were better than in the plaster group: 8.17 versus 6.96 (P=0.001). CAD implants were significantly less detectable than the plaster group implants. The operating time was reduced in the CAO group: 60.2 compared to 74.7minutes in the plaster group (P=0.04), as was the length of hospitalization: 3.5 versus 5.3 days (P=0.01). There were no significant differences between the two groups in terms of post-operative complications. The management of pectus excavatum by a custom-made silicone implant is a minimally invasive method that provides good cosmetic results. The design of these implants is facilitated and qualitatively improved by CAD. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  11. Hidden electronic rule in the “cluster-plus-glue-atom” model

    PubMed Central

    Du, Jinglian; Dong, Chuang; Melnik, Roderick; Kawazoe, Yoshiyuki; Wen, Bin

    2016-01-01

    Electrons and their interactions are intrinsic factors to affect the structure and properties of materials. Based on the “cluster-cluster-plus-glue-atom” model, an electron counting rule for complex metallic alloys (CMAs) has been revealed in this work (i. e. the CPGAMEC rule). Our results on the cluster structure and electron concentration of CMAs with apparent cluster features, indicate that the valence electrons’ number per unit cluster formula for these CMAs are specific constants of eight-multiples and twelve-multiples. It is thus termed as specific electrons cluster formula. This CPGAMEC rule has been demonstrated as a useful guidance to direct the design of CMAs with desired properties, while its practical applications and underlying mechanism have been illustrated on the basis of CMAs’ cluster structural features. Our investigation provides an aggregate picture with intriguing electronic rule and atomic structural features of CMAs. PMID:27642002

  12. Bouncers, brokers, and glue: the self-described roles of social workers in urban hospitals.

    PubMed

    Craig, Shelley L; Muskat, Barbara

    2013-02-01

    Social workers delivering services in health care settings face unique challenges and opportunities. The purpose of this study was to solicit input from social workers employed in urban hospitals about their perceptions of the roles, contribution, and professional functioning of social work in a rapidly changing health care environment. Using qualitative methods, the university and hospital-based research team conducted seven focus groups (n = 65) at urban hospitals and analyzed the data using an interpretive framework with ATLAS.ti software. Seven major themes emerged from the participants' description of their roles: bouncer, janitor, glue, broker, firefighter, juggler, and challenger. Along with descriptions of the ways social workers fulfilled those roles, participants articulated differences in status within those roles, the increasing complexity of discharge planning, and expectations to provide secondary support to other health care professionals on their teams. Implications for practice and research are discussed.

  13. Krazy Glue® in the ear: A case report of child abuse.

    PubMed

    Sorichetti, Brendan D; Fandiño, Marcela; Kozak, Frederick K

    2018-06-01

    Krazy Glue ® or cyanoacrylate glue is an acrylic resin that polymerizes in less than a minute when in contact with moisture or water. We present a case of a one month old referred to our tertiary pediatric otolaryngology clinic from an outside emergency department with a history of application of cyanoacrylate glue in the external ear canals. This report presents the management of this case along with the medical and legal outcomes surrounding this case of child abuse. Copyright © 2018. Published by Elsevier B.V.

  14. Vivostat®: an autologous fibrin sealant as useful adjunct in endoscopic transnasal CSF-leak repair.

    PubMed

    Tomazic, Peter Valentin; Edlinger, Stefan; Gellner, Verena; Koele, Wolfgang; Gerstenberger, Claus; Braun, Hannes; Mokry, Michael; Stammberger, Heinz

    2015-06-01

    The benefit of fibrin glue for reduction of postoperative CSF-leaks after endoscopic skull base surgery is not clearly evident in literature. However, its use is supposed to be beneficial in fixing grafting material. As of today there is no specific data available for otolaryngological procedures. A retrospective data analysis at a tertiary care referral center on 73 patients treated endoscopically transnasally for CSF-leaks at the ENT-department Graz between 2009 and 2012 was performed. Primary closure rate between conventional fibrin glue and autologous fibrin glue were analyzed. The Vivostat(®) system was used in 33 CSF-leak closures and in 40 cases conventional fibrin glue was used. Comparing the two methods the primary closure rate using the autologous Vivostat(®) system was 75.8 and 85.0 % with conventional fibrin glue. The secondary closure the rates were 90.9 % with Vivostat(®) 92.5 % with conventional fibrin glue. The Vivosat(®) system is a useful adjunct in endoscopic CSF-leak closure. Its advantages over conventional fibrin glue are its application system for fixation of grafting material particularly in underlay techniques. Despite this advantage it cannot replace grafting material or is a substitute for proper endoscopic closure which is reflected by the closure rates.

  15. Augmenting pancreatic anastomosis during whipple operation with fibrin glue: a beneficial technical modification?

    PubMed

    Conaglen, Paul J; Collier, Neil A

    2014-04-01

    Various techniques have been described to try and reduce the rate of anastomotic leak following pancreaticoduodenectomy, which remains a challenge for pancreatic surgeons worldwide. We outline a technique to reinforce the pancreatic anastomosis with a double layer of fibrin glue between suture lines. Our technique for pancreatic anastomosis is described in detail. A review of consecutive pancreaticoduodenectomies by a single surgeon (NAC) since introduction of fibrin glue anastomosis reinforcement was compared with a historical control cohort performed by the same surgeon. Thirty-two consecutive pancreaticoduodenectomies were undertaken between March 2008 and March 2012 by a single surgeon, 30 patients had fibrin glue augmentation of the pancreatico-gastrostomy anastomosis. Median length of stay was 12 days. There were no pancreatic leaks or mortality since adopting fibrin glue for the pancreatic anastomosis; however; this single surgeon series is not large enough to provide statistical evidence of a difference since glue was adopted. Our results since the incorporation of this step in pancreaticoduodenectomy are encouraging. Selective use of glue is worthy of consideration in difficult cases, although confirmation of a reduction in pancreatic leak rate is not yet established, and we advocate a multi-institution randomized controlled trial to explore this. © 2013 The Authors. ANZ Journal of Surgery © 2013 Royal Australasian College of Surgeons.

  16. Comparison of fibrin glue and Vicryl sutures in conjunctival autografting for pterygium surgery.

    PubMed

    Wang, Xiu; Zhang, Yan; Zhou, Lei; Wei, Ruihua; Dong, Lijie

    2017-01-01

    To compare clinical parameters and the tear levels of inflammatory cytokines between pterygium surgery using sutures or fibrin glue. Fifty-six patients with primary pterygium were divided into the suture group and the glue group, in which the autograft was secured with 10-0 Vicryl sutures and fibrin glue, respectively. A questionnaire, slit-lamp examination, Schirmer test, and visual acuity test were performed in all participants. Real-time quantitative PCR (q-PCR) was used to analyze the expression of genes in pterygium and healthy conjunctival tissues. Based on the qPCR results and literature reports, five inflammatory cytokines, including hepatocyte growth factor (HGF), fibroblast growth factor 2 (FGF2), transforming growth factor-β1 (TGF-β1), matrix metalloproteinase 2 (MMP2), and tumor necrosis factor-α (TNF-α), were selected, and their protein levels were measured with enzyme-linked immunosorbent assay (ELISA) in patient tears before surgery as well as at postoperative day 1, 7, and 30. There are 28 patients in either the suture or the glue group. The average duration of surgery was 20.17 ± 3.23 min for the glue group and 32.42 ± 4.47 min for the suture group (p = 0.000). Visual acuity in both groups was improved (p = 0.002) after the surgical procedures. There were more symptoms in the suture group than in the glue group at postoperative day 7 (p = 0.002). Postoperative symptoms disappeared in both groups at 1 month after surgery. Recurrence was observed in one case in the glue group and in two cases in the suture group at the 6 month postoperative follow-up (p = 0.714). In comparison to the preoperative levels (4.33 ± 0.43 ng/ml for the suture group; 4.20 ± 0.26 ng/ml for the glue group), the levels of TNF-α in tears increased in the suture group (5.02 ± 0.49 ng/ml, p = 0.016) and decreased in the glue group (3.84 ± 0.35 ng/ml, p = 0.052) on postoperative day 1. The glue treatment induced higher HGF production (4.78 ± 1.25 ng/ml) than the suture treatment (3.04 ± 1.18 ng/ml) at postoperative day 1 (p = 0.020). Higher levels of TGF-β1 in the glue group were detected at postoperative day 1 (3.71 ± 0.18 ng/ml) and postoperative day 30 (4.50 ± 0.51 ng/ml), compared to those in the suture group, respectively (2.74 ± 0.21 ng/ml, p = 0.000 for day 1; 3.36 ± 0.96 ng/ml, p = 0.017 for postoperative day 30). Fibrin glue is effective and safe for attaching conjunctival autografts with an easy surgical procedure, shortened operating time, and less postoperative discomfort. In the early postoperative period, the protein expression of inflammatory cytokines implicates that fibrin glue may induce accelerated healing and subdued inflammation on the ocular surface compared to sutures.

  17. Plastering. Pre-Apprenticeship Phase 2 Training. Student Training Modules.

    ERIC Educational Resources Information Center

    Hamblen, Ron

    These 20 Student Training Modules on plastering comprise one of nine sets of self-paced learning modules developed for Pre-Apprenticeship Phase 2 Training. (A companion instructor's guide is available separately as CE 031 569.) The modules are designed to impart trade knowledge and skills to the student. Each module contains some or all of the…

  18. Specificity and Sensitivity Ratios of the Pediatric Language Acquisition Screening Tool for Early Referral-Revised.

    ERIC Educational Resources Information Center

    Sherman, Tracy; Shulman, Brian B.

    1999-01-01

    This study examined test characteristics of the Pediatric Language Acquisition Screening Tool for Early Referral-Revised (PLASTER-R), a set of developmental questionnaires for children 3 to 60 months of age. The PLASTER-R was moderately to highly successful in identifying children within normal limits for language development. Test-retest…

  19. Plaster Casts after Antique Sculpture: Their Role in the Elevation of Public Taste and in American Art Instruction.

    ERIC Educational Resources Information Center

    McNutt, James K.

    1990-01-01

    Examines the social, ideological, and cultural forces in colonial United States when plaster casts of Grecian and Roman sculpture were introduced. Describes how they were used in U.S. public schools and art museums to transmit the cultural heritage at the end of the nineteenth century. (KM)

  20. [Toxic mustard plaster dematitis and phototoxic dematitis after application of bergamot oil].

    PubMed

    Weisenseel, P; Woitalla, S

    2005-12-15

    Two cases that illustrate the risks attendant on the therapeutic use of natural medications by laypersons are reported. In the first case, the application of a mustard plaster triggered toxic dermatitis. In the second case, a session in a solarium after the external application of bergamot oil resulted in a phototoxic reaction.

  1. MTR, TRA603. CONTROL ROOM DETAILS. ACOUSTIC PLASTER CEILING, USHAPED CONSOLE, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    MTR, TRA-603. CONTROL ROOM DETAILS. ACOUSTIC PLASTER CEILING, U-SHAPED CONSOLE, INSTRUMENT PANELS, GLASS DOOR, ASPHALT TILE FLOOR AND COLORS. BLAW-KNOX 3150-803-11, 10/1950. INL INDEX NO. 531-0603-00-098-100570, REV. 3. - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID

  2. 21 CFR 358.150 - Labeling of wart remover drug products.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... any product formulated in a collodion-like vehicle. (i) “If product gets into the eye, flush with... minutes.”) “Dry area thoroughly.” (If appropriate: “Cut plaster to fit wart.”) “Apply medicated plaster... water for 5 minutes.”) “Dry area thoroughly. Apply” (select one of the following, as appropriate: “one...

  3. 21 CFR 358.150 - Labeling of wart remover drug products.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... any product formulated in a collodion-like vehicle. (i) “If product gets into the eye, flush with... minutes.”) “Dry area thoroughly.” (If appropriate: “Cut plaster to fit wart.”) “Apply medicated plaster... water for 5 minutes.”) “Dry area thoroughly. Apply” (select one of the following, as appropriate: “one...

  4. 21 CFR 358.150 - Labeling of wart remover drug products.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... any product formulated in a collodion-like vehicle. (i) “If product gets into the eye, flush with... minutes.”) “Dry area thoroughly.” (If appropriate: “Cut plaster to fit wart.”) “Apply medicated plaster... water for 5 minutes.”) “Dry area thoroughly. Apply” (select one of the following, as appropriate: “one...

  5. 21 CFR 358.150 - Labeling of wart remover drug products.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... any product formulated in a collodion-like vehicle. (i) “If product gets into the eye, flush with... minutes.”) “Dry area thoroughly.” (If appropriate: “Cut plaster to fit wart.”) “Apply medicated plaster... water for 5 minutes.”) “Dry area thoroughly. Apply” (select one of the following, as appropriate: “one...

  6. Fort Gordon Woodworth Library: Historic Building Survey

    DTIC Science & Technology

    2008-10-01

    9 4. Wall and Ceiling Finish ...reference room are covered with replacement carpet. 4. Wall and Ceiling Finish : The inside of the exterior walls are covered with plaster. The...individual rooms are divided by 0’-4” partition walls clad WOODWORTH LIBRARY (page 10) with a mixture of drywall and wood paneling. A 3’-0” plaster

  7. View of Arcade interior at entrance to Snack House Restaurant. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    View of Arcade interior at entrance to Snack House Restaurant. Note scored plaster detail replicating stone construction joints on brick rearing walls, and detailed plaster relief panels. Various color schemed from panels and cornice details are visible throughout the building and in historic photographs - Post Office Arcade, 2118 First Street, Fort Myers, Lee County, FL

  8. A comparative study of tissue glue and vicryl suture for conjunctival and scleral closure in conventional 20-gauge vitrectomy.

    PubMed

    Batman, C; Ozdamar, Y; Mutevelli, S; Sonmez, K; Zilelioglu, G; Karakaya, J

    2009-06-01

    To describe the use of tissue glue to close scleral and conjunctival wounds, and to compare the clinical outcomes using tissue glue and vicryl suture for closing these areas in conventional 20-gauge (G) vitrectomy. Thirty eyes of 30 patients were included in this study. The indications for vitreoretinal surgery were diabetic vitreous haemorrhage with severe vitreoretinal traction in 10 eyes, retinal detachment and proliferative vitreoretinopathy in 14 eyes, and vitreous opacity in 6 eyes. Tissue glue (Tisseel, Baxter AG Industries, Vienna, Austria) was used to attach scleral and conjunctival wounds in 15 eyes and vicryl sutures in 15 eyes. The patients were allotted into two subgroups as tissue glue group (TG) and vicryl suture group (VG). The sclerotomy sites were evaluated with ultrasound biomicroscopy (UBM) postoperatively in TG. Follow-up period was 2 months. The groups were statistically compared for ocular signs and symptoms by Mann-Whitney U-test. No scleral wound leakage and conjunctival reattachment were observed at the end of the surgical procedure and during the follow-up period. No adverse effects were seen in TG. Abnormal fibrous ingrowth was not detected at the sclerotomy sites by means of UBM in TG. Patient comfort was significantly higher in TG than VG (P<0.05). Tissue glue has no adverse effects on ocular tissue and can be used as a substitute for suture materials, and the use of tissue glue decreases patient symptoms during the postoperative period after 20-G vitrectomy. Tissue glue can enable to perform sutureless surgery in the conventional 20-G vitrectomy.

  9. Accuracy of digital American Board of Orthodontics Discrepancy Index measurements.

    PubMed

    Dragstrem, Kristina; Galang-Boquiren, Maria Therese S; Obrez, Ales; Costa Viana, Maria Grace; Grubb, John E; Kusnoto, Budi

    2015-07-01

    A digital analysis that is shown to be accurate will ease the demonstration of initial case complexity. To date, no literature exists on the accuracy of the digital American Board of Orthodontics Discrepancy Index (DI) calculations when applied to pretreatment digital models. Plaster models were obtained from 45 previous patients with varying degrees of malocclusion. Total DI scores and the target disorders were computed manually with a periodontal probe on the original plaster casts (gold standard) and digitally using Ortho Insight 3D (Motion View Software, Hixson, Tenn) and OrthoCAD (Cadent, Carlstadt, NJ). Intrarater and interrater reliabilities were assessed for 15 subjects using the Spearman rho correlation test. Accuracies of the DI scores and target disorders were assessed for all 45 subjects using Wilcoxon signed ranks tests. Intrarater and interrater reliabilities were high for total DI scores and most target disorders (r > 0.8). No significant difference was found between total DI score when measured with OrthoCAD compared with manual calculations. The total DI scores calculated by Ortho Insight 3D were found to be significantly greater than those by manual calculation by 2.71 points. The findings indicate that a DI calculated by Ortho Insight 3D may lead the clinician to overestimate case complexity. OrthoCAD's DI module was demonstrated to be a clinically acceptable alternative to manual calculation of the total scores. Copyright © 2015 American Association of Orthodontists. Published by Elsevier Inc. All rights reserved.

  10. Commissioning of the pair spectrometer of the GlueX experiment

    DOE PAGES

    Somov, A.; Tolstukhin, I.; Somov, S. V.; ...

    2017-03-07

    The main goal of the pair spectrometer of the GlueX experiment at Jefferson Lab is to determine the photon beam flux and to measure beam polarization. Here, we present the design of the pair spectrometer and the performance results during the first commissioning runs of the GlueX experiment.

  11. Endoscopic Ultrasound (EUS) for Esophageal and Gastric Varices: How Can it Improve the Outcomes and Reduce Complications of Glue Injection

    PubMed Central

    Bhatia, Vikram

    2012-01-01

    A large part of portal venous system and the paragastric and para-esophageal collateral circulation is within the reach of endoscopic ultrasound (EUS). The EUS is more sensitive than gastroscopy for the detection of gastric varices (GV), and can accurately distinguish GV from thickened gastric folds. Gastric varices are depicted by serpiginous, anechoic, Doppler-positive mural channels, with larger collateral channels visible outside the gastric wall. The EUS has also been used to monitor the completeness of GV obturation after glue injection. There are limited data that this strategy may be clinically beneficial to prevent GV re-bleed. The EUS has been used to deliver glue injections under real-time monitoring into the vascular channels, with or without steel coils as scaffolding for the glue. The potential advantages of this technique include a straight scope position, lack of hindrance from pooled blood in gastric fundus, smaller glue volume requirements, and precise intra-vascular placement of glue with avoidance of intramural injections, and reduced embolic complications. PMID:25755407

  12. Fibrin glue as a protective tool for microanastomoses in limb reconstructive surgery

    PubMed Central

    Langer, Stefan; Schildhauer, Thomas A.; Dudda, Marcel; Sauber, Jeannine; Spindler, Nick

    2015-01-01

    Aim: Fibrin glue becomes a more and more routinely used tool for stabilization of microanastomoses and nerve repair. This paper summarizes the technical properties and advantages of its use in a wide variety of microsurgical contexts, and includes an exemplary limb reconstructive case. Patients and methods: A total of 131 patients who had undergone elective and emergency microsurgery mainly of the limbs were retrospectively analyzed, as was the use of free flaps. Results: The use of fibrin glue allows for proper positioning of anastomoses and repaired nerves. No torsion of the pedicle could be seen. The flap survival rated >94%. The fibrin glue could stay in place in >99%. In the rare case of revision, the fibrin glue could easily be removed without damaging the region of the microanastomosis. Conclusion: Fibrin glue should not be used to repair insufficient, i.e., leaking anastomoses, but it does protect the site of anastomosis from tissue and fluid pressure. It prevents the pedickle from torsion and its use facilitates relocation of the microanastomoses in cases of revision surgery. PMID:26759762

  13. Mega-features at the Table Rock phreatomagmatic complex in Christmas Valley, Oregon; Law of original horizontality need not apply

    NASA Astrophysics Data System (ADS)

    Brand, B. D.; Clarke, A.

    2006-12-01

    The Table Rock Complex (TRC; Pliocene-Pleistocene), first documented and described by (Heiken, 1971, J. Geophy Res, 76, 5615-5626) is a large and well exposed phreatomagmatic complex in the Fort Rock- Christmas Lake Valley Basin, south-central Oregon. It is ~7 by 5 km and contains two large phreatomagmatic edifices; a large southern tuff cone with a capping lava lake (TRC1), and a large broad tuff ring in the northeast (TRC2). At least five additional, smaller tuff rings were identified along the flanks of the complex, yielding a complicated network of tuff ring-tuff cone deposits. Based on the low accidental component and evidence for a lake during this time, the cause of the explosive eruptions is interpreted to be due to interaction of magma with shallow standing water. The TRC1 consists of fining-up sequences, large erosive channel scour and fill deposits, massive tuff breccias, and abundant soft sediment deformation, which suggests deposition within a standing body of water. Subaerial TRC1 deposits are found south of the edifice, but are not exposed in the north. A significant repose period occurred between the TRC1 and TRC2 eruptions, evidenced by a wave-cut terrace and 25-50 cm of diatomitic lake sediments. TRC2 produced multiple, extremely erosive pyroclastic surges, which cut and scour the TRC1 deposits. Surge deposits consist of 50-200 m wavelength cross-beds, in some areas form large U-shaped features (10-100 m deep), and can be seen plastering up and around large obstacles from previous vents. The surge-deposits blanket all other sequences and create a hummocky topography around the edifice. This suggests that TRC2 was the last eruption in the sequence. The weight of the TRC2 sediments caused the water-saturated TRC1 sediments to plastically deform into large ball and pillow features and overturned slump blocks on the order of 20-50 m thick. The smaller flank tuff-ring eruptions likely occurred sometime between the TRC1 and TRC2 events. The inner-craters of these vents are well exposed and show features such as near-vertical plastered beds, large-scale convolute bedding, and in some places deformed and folded slump blocks up to 20-120 m thick. The features observed in both TRC deposits and in the smaller flank tuff rings (e.g., large-scale soft sediment deformation, plastered-vertical bedding, accretionary/armored lapilli) are consistent with a high water-magma ratio. The highly erosive surge beds of TRC2 represent the most energetic pulse of the eruptions.

  14. Axillary lymphadenectomy for breast cancer in elderly patients and fibrin glue

    PubMed Central

    2013-01-01

    Background Axillary lymphadenectomy or sentinel biopsy is integral part of breast cancer treatment, yet seroma formation occurs in 15-85% of cases. Among methods employed to reduce seroma magnitude and duration, fibrin glue has been proposed in numerous studies with controversial results. Methods Thirty patients over 60 years underwent quadrantectomy or mastectomy with level I/II axillary lymphadenectomy; a suction drain was fitted in all patients. Fibrin glue spray were applied to the axillary fossa in 15 patients; the other 15 patients were treated with harmonic scalpel. Results Suction drainage was removed between post-operative Days 3 and 4. Seroma magnitude and duration were not significant in patients receiving fibrin glue compared with the harmonic scalpel group. Conclusions Use of fibrin glue does not always prevent seroma formation, but can reduce seroma magnitude, duration and necessary evacuative punctures. PMID:24266959

  15. Fibrin glue in ophthalmology

    PubMed Central

    Panda, Anita; Kumar, Sandeep; Kumar, Abhiyan; Bansal, Raseena; Bhartiya, Shibal

    2009-01-01

    Suturing is a time consuming task in ophthalmology and suture induced irritation and redness are frequent problems. Postoperative wound infection and corneal graft rejection are examples of possible suture related complications. To prevent these complications, ophthalmic surgeons are switching to sutureless surgery. A number of recent developments have established tissue adhesives like cyanoacrylate glue and fibrin glue as attractive alternatives to sutures. A possible and promising new application for tissue adhesives is to provide a platform for tissue engineering. Currently, tissue glue is being used for conjunctival closure following pterygium and strabismus surgery, forniceal reconstruction surgery, amniotic membrane transplantation, lamellar corneal grafting, closure of corneal perforations and descematoceles, management of conjunctival wound leaks after trabeculectomy, lid surgery, adnexal surgery and as a hemostat to minimise bleeding. The purpose of this review is to discuss the currently available information on fibrin glue. PMID:19700876

  16. Managing Scientific Software Complexity with Bocca and CCA

    DOE PAGES

    Allan, Benjamin A.; Norris, Boyana; Elwasif, Wael R.; ...

    2008-01-01

    In high-performance scientific software development, the emphasis is often on short time to first solution. Even when the development of new components mostly reuses existing components or libraries and only small amounts of new code must be created, dealing with the component glue code and software build processes to obtain complete applications is still tedious and error-prone. Component-based software meant to reduce complexity at the application level increases complexity to the extent that the user must learn and remember the interfaces and conventions of the component model itself. To address these needs, we introduce Bocca, the first tool to enablemore » application developers to perform rapid component prototyping while maintaining robust software-engineering practices suitable to HPC environments. Bocca provides project management and a comprehensive build environment for creating and managing applications composed of Common Component Architecture components. Of critical importance for high-performance computing (HPC) applications, Bocca is designed to operate in a language-agnostic way, simultaneously handling components written in any of the languages commonly used in scientific applications: C, C++, Fortran, Python and Java. Bocca automates the tasks related to the component glue code, freeing the user to focus on the scientific aspects of the application. Bocca embraces the philosophy pioneered by Ruby on Rails for web applications: start with something that works, and evolve it to the user's purpose.« less

  17. Fibrin glue for pilonidal sinus disease.

    PubMed

    Lund, Jon; Tou, Samson; Doleman, Brett; Williams, John P

    2017-01-13

    Pilonidal sinus disease is a common condition that mainly affects young adults. This condition can cause significant pain and impairment of normal activities. No consensus currently exists on the optimum treatment for pilonidal sinus and current therapies have various advantages and disadvantages. Fibrin glue has emerged as a potential treatment as both monotherapy and an adjunct to surgery. To assess the effects of fibrin glue alone or in combination with surgery compared with surgery alone in the treatment of pilonidal sinus disease. In December 2016 we searched: the Cochrane Wounds Specialised Register; CENTRAL; MEDLINE; Embase and CINAHL Plus. We also searched clinical trials registries and conference proceedings for ongoing and unpublished studies and scanned reference lists to identify additional studies. There were no restrictions with respect to language, date of publication or study setting. We included randomised controlled trials (RCTs) only. We included studies involving participants of all ages and studies conducted in any setting. We considered studies involving people with both new and recurrent pilonidal sinus. We included studies which evaluated fibrin glue monotherapy or as an adjunct to surgery. Two study authors independently extracted data and assessed risk of bias. We used standard methods expected by Cochrane. We included four RCTs with 253 participants, all were at risk of bias. One unpublished study evaluated fibrin glue monotherapy compared with Bascom's procedure, two studies evaluated fibrin glue as an adjunct to Limberg flap and one study evaluated fibrin glue as an adjunct to Karydakis flap.For fibrin glue monotherapy compared with Bascom's procedure, there were no data available for the primary outcomes of time to healing and adverse events. There was low-quality evidence of less pain on day one after the procedure with fibrin glue monotherapy compared with Bascom's procedure (mean difference (MD) -2.50, 95% confidence interval (CI) -4.03 to -0.97) (evidence downgraded twice for risk of performance and detection bias). Fibrin glue may reduce the time taken to return to normal activities compared with Bascom's procedure (mean time 42 days with surgery and 7 days with glue, MD -34.80 days, 95% CI -66.82 days to -2.78 days) (very low-quality evidence, downgraded as above and for imprecision).Fibrin glue as an adjunct to the Limberg flap may reduce the healing time from 22 to 8 days compared with the Limberg flap alone (MD -13.95 days, 95% CI -16.76 days to -11.14 days) (very low-quality evidence, downgraded twice for risk of selection, performance and detection bias and imprecision). It is uncertain whether use of fibrin glue affects the incidence of postoperative seroma (an adverse event) (risk ratio (RR) 0.27, 95% CI 0.05 to 1.61; very low-quality evidence, downgraded twice for risk of selection, performance and detection bias and imprecision). There was low-quality evidence that fibrin glue, as an adjunct to Limberg flap, may reduce postoperative pain (median 2 versus 4; P < 0.001) and time to return to normal activities (median 8 days versus 17 days; P < 0.001). The addition of fibrin glue to the Limberg flap may reduce the length of hospital stay (MD -1.69 days, 95% CI -2.08 days to -1.29 days) (very low-quality evidence, downgraded twice for risk of selection, performance and detection bias and for unexplained heterogeneity).A single RCT evaluating fibrin glue as an adjunct to the Karydakis flap did not report data for the primary outcome of time to healing. It is uncertain whether fibrin glue with the Karydakis flap affects the incidence of postoperative seroma (adverse event) (RR 3.00, 95% CI 0.67 to 13.46) (very low-quality evidence, downgraded twice for risk of selection, performance and detection bias and for imprecision). Fibrin glue as an adjunct to Karydakis flap may reduce length of stay but this is highly uncertain (mean 2 days versus 3.7 days; P < 0.001, low-quality evidence downgraded twice for risk of selection, performance and detection bias). Current evidence is uncertain regarding any benefits associated with fibrin glue either as monotherapy or as an adjunct to surgery for people with pilonidal sinus disease. We identified only four RCTs and each was small and at risk of bias resulting in very low-quality evidence for the primary outcomes of time to healing and adverse events. Future studies should enrol many more participants, ensure adequate randomisation and blinding, whilst measuring clinically relevant outcomes.

  18. Efficacy of bubaline fibrin glue on full-thickness pinch and punch skin grafting in a pig.

    PubMed

    Dejyong, Krittee; Kaewamatawong, Theerayuth; Brikshavana, Pasakorn; Durongphongtorn, Sumit

    2017-03-01

    Fibrin glue, which is formed from the action of thrombin (a serine protease) on fibrinogen, has been developed for use as an adhesive to increase the success of skin graft surgery. The objective of this study was to evaluate if bubaline fibrin glue would promote skin graft survival in pigs. The grafting was divided into two steps. First, granulation wound preparation was performed in a healthy swine by creating four full-skin depth wounds (3 × 12 cm 2 ) at the dorsal part of the loin area on each side. Second, pinch and punch skin grafting, where eight skin discs (0.6 cm diameter) were regularly placed (0.6 cm distance apart) in the granulation tissue bed of each wound, was performed 5 days later. The bubaline fibrin glue was added prior to application of the 16 skin graft discs in two of the wounds, while no glue was added to the other 16 skin graft discs in the other two wounds. The number of surviving graft pieces and histological examination was evaluated after 3, 7, and 14 days post-operation and compared by pairing between the control and the bubaline fibrin glue groups. The number of grafts that remained at 3 and 7 days post-operation and the number of new microvessels at 3 days post-operation were significantly higher ( p < 0.05) in the bubaline fibrin glue group than in the control group. However, there was no significant difference in the number of fibroblasts, the intensity of scarring and the intensity of inflammation between the two groups, except for the significantly lower intensity of inflammation at 7 days post-operation in the bubaline fibrin glue group. In conclusion, bubaline fibrin glue has the advantage of decreasing the skin graft loss by approximately 31.3-37.5% compared with the control group and also promotes angiogenesis.

  19. Accuracy and eligibility of CBCT to digitize dental plaster casts.

    PubMed

    Becker, Kathrin; Schmücker, Ulf; Schwarz, Frank; Drescher, Dieter

    2018-05-01

    Software-based dental planning requires digital casts and oftentimes cone-beam computed tomography (CBCT) radiography. However, buying a dedicated model digitizing device can be expensive and might not be required. The present study aimed to assess whether digital models derived from CBCT and models digitized using a dedicated optical device are of comparable accuracy. A total of 20 plaster casts were digitized with eight CBCT and five optical model digitizers. Corresponding models were superimposed using six control points and subsequent iterative closest point matching. Median distances were calculated among all registered models. Data were pooled per scanner and model. Boxplots were generated, and the paired t test, a Friedman test, and a post-hoc Nemenyi test were employed for statistical comparison. Results were found significant at p < 0.05. All CBCT devices allowed the digitization of plaster casts, but failed to reach the accuracy of the dedicated model digitizers (p < 0.001). Median distances between CBCT and optically digitized casts were 0.064 + - 0.005 mm. Qualitative differences among the CBCT systems were detected (χ 2  = 78.07, p < 0.001), and one CBCT providing a special plaster cast digitization mode was found superior to the competitors (p < 0.05). CBCT systems failed to reach the accuracy from optical digitizers, but within the limits of the study, accuracy appeared to be sufficient for digital planning and forensic purposes. Most CBCT systems enabled digitization of plaster casts, and accuracy was found sufficient for digital planning and storage purposes.

  20. Terahertz analysis of stratified wall plaster at buildings of cultural importance across Europe

    NASA Astrophysics Data System (ADS)

    Walker, Gillian C.; Jackson, J. Bianca; Giovannacci, David; Bowen, John W.; Delandes, Bruno; Labaune, Julien; Mourou, Gerard; Menu, Michel; Detalle, Vincent

    2013-05-01

    Terahertz (THz) radiation is being developed as a tool for the analysis of cultural heritage, and due to recent advances in technology is now available commercially in systems which can be deployed for field analysis. The radiation is capable of penetrating up to one centimetre of wall plaster and is delivered in ultrafast pulses which are reflected from layers within this region. The technique is non-contact, non-invasive and non-destructive. While sub-surface radar is able to penetrate over a metre of wall plaster, producing details of internal structures, infrared and ultraviolet techniques produce information about the surface layers of wall plaster. THz radiation is able to provide information about the interim region of up to approximately one centimetre into the wall surface. Data from Chartres Cathedral, France, Riga Dome Cathedral, Latvia, and Chartreuse du Val de Bénédiction, France is presented each with different research questions. The presence of sub-surface paint layers was expected from documentary evidence, dating to the 13th Century, at Chartres Cathedral. In contrast, at the Riga Dome Cathedral surface painting had been obscured as recently as 1941 during the Russian occupation of Latvia using white lead-based paint. In the 13th Century, wall paintings at the Chapel of the Frescos, Chartreuse du Val de Benediction in Villeneuve les Avignon were constructed using sinopia under-painting on plaster covering uneven stonework.. This paper compares and contrasts the ability of THz radiation to provide information about sub-surface features in churches and Cathedrals across Europe by analysing depth based profiles gained from the reflected signal.

  1. Effects of forced deep breathing on blood flow velocity in the femoral vein: Developing a new physical prophylaxis for deep vein thrombosis in patients with plaster cast immobilization of the lower limb.

    PubMed

    Nakanishi, Keisuke; Takahira, Naonobu; Sakamoto, Miki; Yamaoka-Tojo, Minako; Katagiri, Masato; Kitagawa, Jun

    2018-02-01

    Patients with plaster cast immobilization of the lower limb have an estimated symptomatic venous thromboembolism rate of 5.5%. However, there is currently no practical physical prophylaxis for deep-vein thrombosis (DVT). The objective of this study was to examine the effects of forced deep breathing on peak blood velocity in the superficial femoral vein (PBVFV), which is a surrogate measure of the efficacy of thromboprophylaxis against DVT, in patients with plaster cast immobilization of the lower limb. Nine young males and 18 elderly males were recruited. We immobilized the right lower limb of each subject with a plaster splint and measured PBVFV during forced deep breathing in supine and sitting positions. In all subjects, PBVFV during forced deep breathing in both positions was significantly higher than at rest. There was no significant difference in the PBVFV change ratio for three breathing rates in the sitting position for the young subjects (15breaths/min: 415%, 5breaths/min: 475%, 3breaths/min: 483%), whereas that for the elderly subjects at 3breaths/min (449%) was significantly higher than that at 15breaths/min (284%). Forced deep breathing significantly increased PBVFV in patients with plaster cast immobilization of the lower limb in both supine and sitting positions. Testing the efficacy and adherence in clinical contexts, and following up with the incidence rate of DVT in future studies, is necessary for the development of a new physical prophylaxis for DVT. Copyright © 2017 Elsevier Ltd. All rights reserved.

  2. Far infrared emitting plaster in knee osteoarthritis: a single blinded, randomised clinical trial.

    PubMed

    Bagnato, G L; Miceli, G; Atteritano, M; Marino, N; Bagnato, G F

    2012-12-20

    Therapeutic approach of osteoarthritis (OA) still represents a challenge in clinical practice. The aim of the study is to assess the efficacy of far infrared (FIR) emitting plaster in the treatment of knee OA. This is a randomized, single-blind, placebo-controlled, parallel group with equal randomization (1:1), clinical trial. Patients affected by knee OA were randomly allocated to 1 of 2 treatment groups, either placebo plaster or far infrared emitting plaster. Primary endpoint was to assess pain improvement from baseline to 1 months posttreatment in the visual analogue score (VAS). Secondary end point was to evaluate pain score after 1 week of treatment and to compare ultrasonographic findings after 1 month of treatment. Each group comprised 30 (in the FIR group) and 30 (in the placebo group) completers. VAS scores of the placebo and the FIR group were significantly lower at 1 week post-treatment (95% confidence interval CI = -1.14 to 0.31; P<0.05) and at the end of the study (95% confidence interval CI = -2.57 to -0.89; P=0.01). Effect size was -0.43 after one week of treatment and -1.38 after one month of treatment. The mean decrease in VAS values was ≥ 20% in the FIR group. The number of patients from the FIR group with joint effusion was lower (40%) compared to baseline (80%), while no changes were seen among the placebo group. Far infrared emitting plaster could be considered an effective non-pharmacological choice for the therapeutic management of knee OA.

  3. The properties of gelatin-poly (gamma-glutamic acid) hydrogels as biological glues.

    PubMed

    Hsu, Shan-Hui; Lin, Chen-Huan

    2007-01-01

    The influence of the molecular weight and the type of gelatin (A or B), as well as the molecular weight of poly (gamma-glutamic acid) (gamma-PGA), on the properties of gelatin/gamma-PGA mixed bioadhesives were studied. The gelation of the system was enhanced by a crosslinker, 1-(3-dimethylaminopropyl)-3-(ethylcarbodiimide) hydrochloride (EDC). The gelation time of the bioadhesives was analyzed using rheological measurements. The results indicated that the type of gelatin was a critical factor in determining the gelation time of the biological glues. The mixed glues had greater bonding strength and smaller gelation times as the molecular weight of gamma-PGA or gelatin increased. The swelling ratio decreased and the denaturation temperature increased upon raising the EDC concentration, indicating a greater degree of crosslinking at higher EDC concentrations. The mixed glues crosslinked with various concentrations of EDC (1.7-2.5%) showed no cytotoxicity to fibroblasts. In addition, no significant inflammatory response was observed in the rat subcutaneous implantation. The bioadhesives based on gelatin/gamma-PGA remained at the site for 7 days while the fibrin glue had almost completely degraded. By choosing the appropriate gelatin type and higher molecular weight gamma-PGA in the mixtures, the gelatin/gamma-PGA biological glues could serve as soft tissue adhesives. Rheological characterization was essential in the evaluation of biological glues.

  4. Occupational contact dermatitis caused by aniline epoxy resins in the aircraft industry.

    PubMed

    Pesonen, Maria; Suuronen, Katri; Jolanki, Riitta; Aalto-Korte, Kristiina; Kuuliala, Outi; Henriks-Eckerman, Maj-Len; Valtanen, Ilona; Alanko, Kristiina

    2015-08-01

    Tetraglycidyl-4,4'-methylenedianiline (TGMDA) is an aniline epoxy resin used in, for example, resin systems of pre-impregnated composite materials (prepregs) of the aircraft industry. Allergic contact dermatitis caused by TGMDA in prepregs has been described previously. To report on 9 patients with occupational allergic contact dermatitis caused by TGMDA in epoxy glues used in helicopter assembly. The patients were examined with patch testing at the Finnish Institute of Occupational Health in 2004-2009. The first patient was diagnosed by testing both components of two epoxy glues from the workplace, and was also tested with glue ingredients, including TGMDA. The following patients were tested with the glues and TGMDA. The resin parts of the glues were analysed for their epoxy compounds, including TGMDA. All of the patients had a patch test reaction to one or both of the resin parts of the TGMDA-containing glues. Eight of them had a strong allergic reaction to TGMDA, and one had a doubtful reaction to TGMDA. Two of the patients also had an allergic reaction to triglycidyl-p-aminophenol (TGPAP), another aniline epoxy resin, which was not present in the TGMDA-containing glues. In aircraft industry workers with suspected occupational dermatitis, aniline epoxy resins should be considered and patch tested as possible contact allergens. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  5. Assessment of the feasibility and clinical value of further research to evaluate the management options for children with Down syndrome and otitis media with effusion: a feasibility study.

    PubMed

    Fortnum, Heather; Leighton, Paul; Smith, Murray D; Brown, Lisa; Jones, Matthew; Benton, Claire; Marder, Elizabeth; Marshall, Andrew; Sutton, Kate

    2014-09-01

    There is clinical uncertainty of the benefits and costs of different treatment options for children with Down syndrome who have glue ear. This study was designed to assess the extent of this lack of knowledge and determine if pursuing further information would be practical, beneficial and cost-effective. To assess the level and practical effect of current uncertainty around treatment options for children with Down syndrome and glue ear. To assess the feasibility of studying the options for management of glue ear in children with Down syndrome via a randomised controlled trial (RCT) or multicentre prospective cohort study by evaluating the willingness of (1) parents to agree to randomisation for their children and (2) clinicians to recruit participants to a definitive study. To undertake value of information analyses to demonstrate the potential economic benefit from undertaking further research. A feasibility study exploring the views of parents of children with Down syndrome and professionals who have responsibility for the health and education of children with Down syndrome, on the participation in, and value of, future research into interventions for glue ear. Data were collected from parents via self-completed questionnaires, face-to-face interviews and focus groups and from professionals via online questionnaires and a Delphi review exercise. Development of economic models to represent clinical pathways of care and a RCT informed a value of information (VOI) analysis. UK (professionals); East Midlands region of the UK (parents). Parents of children aged 1-11 years with Down syndrome (n = 156). Professionals including audiologists, ear, nose and throat surgeons, audiological physicians, speech and language therapists, and teachers of the deaf (n = 128). Quantitative and qualitative data on parental views and experiences of glue ear and its effects; interventions and treatment received; taking part in research and factors that would encourage or discourage participation; and the importance of various outcome domains to them and for their children. For professionals: information on caseloads; approaches to clinical management; opinions on frequency and significance of the consequences of glue ear for this population; importance of different outcome measures; opinions of interventions and their role in future research; views on health research; facilitators and barriers to recruitment, and participation in research involving RCTs. The complexity of the experience and individual characteristics of children with Down syndrome poses challenges for the design of any future research but these challenges were not considered by professionals to raise sufficient barriers to prevent it being undertaken. Parents were generally supportive of the need for, and value of, research but identified practical and emotional issues that would need addressing. Glue ear was considered to impact more on speech, language and communication than on hearing. Outcome measures for future research would need to evaluate these elements but measures should be designed specifically for the population. Parents and professionals identified randomisation as a significant barrier to participation. The VOI analyses identified lack of data as problematic but concluded that a future trial involving surgical intervention would be feasible at costs of < £650,000. Future research into the benefits of interventions for glue ear in children with Down syndrome would be feasible and could be cost-effective but should be carefully designed to facilitate and maximise participation from parents and professionals responsible for recruitment. The National Institute for Health Research Health Technology Assessment programme.

  6. 21 CFR 358.150 - Labeling of wart remover drug products.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ....” (iv) “Do not use on moles, birthmarks, warts with hair growing from them, genital warts, or warts on... minutes.”) “Dry area thoroughly.” (If appropriate: “Cut plaster to fit wart.”) “Apply medicated plaster... water for 5 minutes.”) “Dry area thoroughly. Apply” (select one of the following, as appropriate: “one...

  7. The Contributions Regarding the Use of Microwave to Obtain Modeling Gypsum for Phonic-Absorbent Construction and Orthopedic Materials

    NASA Astrophysics Data System (ADS)

    Pop, P. A.; Ungur, P. A.; Caraban, A.; Marcu, F.

    2009-11-01

    The paper has presented some experiments realized at "Congips" Co. Oradea and University of Oradea, regarding of increase machining efficiency and quality for modeling gypsum plaster by using of microwave energy to gypsum ore roast. The elaboration process of microwave energy for modeling gypsum plaster has done on electromagnetic waves properties and specific properties for dielectric materials. Microwaves are radiations of electromagnetic waveform nature, determine by pulsations of electrical-E) and magnetically-H components of electromagnetic wave in interdependence with Maxwell equations. The gypsum ore is calcium sulphate dehydrate (CaSO4ṡ2H2O) using at modeling gypsum plaster fabrication, which is calcium sulphate hemihydrate (CaSO4ṡ1/2H2O), that has behavior of dielectric with losses. The gypsum ore getting in microwave field, in conditions of predictable pressure and temperature has transformed in modeling gypsum plaster, by quick lost of a part from crystallization water. The processing time is very short, which due to a great productivity and machining efficiency, finally of low process cost. All of these recommend continuing the research at pilot station level.

  8. Properties of a hybrid plaster-fibreglass cast

    PubMed Central

    Charles, Mark N.; Yen, David

    2000-01-01

    Objective To examine the suitability of a plaster-fibreglass hybrid cast for orthopedic applications, comparing them to plaster of Paris (POP) and fibreglass constructs. Method Groups of 10 standardized hybrid, POP and fibreglass casts were studied. An Instron servo-hydraulic system was used to test the casts in 3-point bending and shear. Outcome measures Strength, stiffness, weight, thickness and cost of the 3 types of cast, and shear strength at the interface between the POP and fibreglass in the hybrid casts. Results The hybrid casts were twice as strong as the POP constructs, were stiffer and weighed 14% less but were thicker and cost 2.5 times more. They were almost as strong as and less than half the cost of the fibreglass constructs but were thicker, not as stiff, and weighed 42% more. The shear strength of the POP–fibreglass interface in the hybrid casts was higher than the 3-point bending strength of this construct by a factor of 3. Conclusions Plaster-fibreglass hybrid casts should be considered for orthopedic use on the basis of their strength, stiffness, weight and cost, combined with their acknowledged advantages of good moulding ability and water resistance. PMID:11045095

  9. Delamination of plasters applied to historical masonry walls: analysis by acoustic emission technique and numerical model

    NASA Astrophysics Data System (ADS)

    Grazzini, A.; Lacidogna, G.; Valente, S.; Accornero, F.

    2018-06-01

    Masonry walls of historical buildings are subject to rising damp effects due to capillary or rain infiltrations, which in the time produce decay and delamination of historical plasters. In the restoration of masonry buildings, the plaster detachment frequently occurs because of mechanical incompatibility in repair mortar. An innovative laboratory procedure is described for test mechanical adhesion of new repair mortars. Compression static tests were carried out on composite specimens stone block-repair mortar, which specific geometry can test the de-bonding process of mortar in adherence with a stone masonry structure. The acoustic emission (AE) technique was employed for estimating the amount of energy released from fracture propagation in adherence surface between mortar and stone. A numerical simulation was elaborated based on the cohesive crack model. The evolution of detachment process of mortar in a coupled stone brick-mortar system was analysed by triangulation of AE signals, which can improve the numerical model and predict the type of failure in the adhesion surface of repair plaster. Through the cohesive crack model, it was possible to interpret theoretically the de-bonding phenomena occurring at the interface between stone block and mortar. Therefore, the mechanical behaviour of the interface is characterized.

  10. A comparison of the mechanical properties of fiberglass cast materials and their clinical relevance.

    PubMed

    Berman, A T; Parks, B G

    1990-01-01

    The mechanical properties of five synthetic fiberglass casting materials were evaluated and compared with the properties of plaster of Paris. Two of the tests were designed to bear clinical relevance and the third to determine intrinsic material properties. The effect of water on strength degradation was also evaluated. It was found that the synthetics as a group are far superior to plaster of Paris in all methods of testing and that, among the synthetics, KCast Tack Free, Deltalite "S", and KCast Improved were the stronger materials. Clinically, the most important results are that the synthetics attain their relatively high strength in a much shorter time frame than does plaster of Paris, and retain 70-90% of their strength after being immersed in water and allowed to dry.

  11. High Strength Phosphogypsum and Its Use as a Building Material

    NASA Astrophysics Data System (ADS)

    Kanno, Wellington Massayuki; Rossetto, Hebert Luis; de Souza, Milton Ferreira; Máduar, Marcelo Francis; de Campos, Marcia Pires; Mazzilli, Barbara Paci

    2008-08-01

    A new process (patent applied) that works equally well with both plaster of mineral gypsum and phosphogypsum for the preparation of gypsum components, UCOS, has been developed. The process consists of the following steps: humidification of plaster by fine water droplets, uni-axial compression, hydration reaction and drying. Strong hydrogen bonds develop among the crystals together with adhesion provided by confined water that accounts for nearly 70% of the adhesion forces. By reducing the plaster to water ratio to close the minimum necessary, new features are generated. An experimental house has been constructed, in which walls and ceilings have been built of gypsum and phosphogypsum. Since phosphogypsum potentially contain radioactive elements, the application of an activity concentration index to the phosphogypsum employed in the building was carried out.

  12. Investigation of the seismic resistance of interior building partitions, phase 1

    NASA Astrophysics Data System (ADS)

    Anderson, R. W.; Yee, Y. C.; Savulian, G.; Barclay, B.; Lee, G.

    1981-02-01

    The effective participation of wood-framed interior shear wall partitions when determining the ultimate resistance capacity of two- and three-story masonry apartment buildings to seismic loading was investigated. Load vs. deflection tests were performed on 8 ft by 8 ft wall panel specimens constructed of four different facing materials, including wood lath and plaster, gypsum lath and plaster, and gypsum wallboard with joints placed either horizontally or vertically. The wood lath and plaster construction is found to be significantly stronger and stiffer than the other three specimens. Analyses of the test panels using finite element methods to predict their static resistance characteristics indicates that the facing material acts as the primary shear-resisting structural element. Resistance of shear wall partitions to lateral loads was assessed.

  13. Spiritual and Religious Supports Part 8: Church G.L.U.E.

    ERIC Educational Resources Information Center

    Newman, Barbara J.

    2009-01-01

    CLC Network is an organization that partners with churches, schools, and families to help promote and build inclusive and interdependent communities for those with disabilities. This article describes CLC Network's most recent tool--a book entitled the G.L.U.E. Training Manual. G.L.U.E. is an adhesive process to allow each individual to be firmly…

  14. Acoustic Identification of Filler Materials in Unexploded Ordnance

    DTIC Science & Technology

    2006-04-01

    PBXN- 103 CH-6 PBXW- 108 Parrafin ( wax ) Baratol (76/24) Plaster TNT Octol (50/50) Comp B PETN Concrete Lo ng itu di na l V el oc ity (m /s ec...26 3.7.3 Identification of Wax fillers...plaster and wax from “other” items including explosives. A series of field tests are described that focus on acoustic measurements on both inert and live

  15. Cohort study on respiratory and neurological disorders among workers in a bone glue factory in Egypt.

    PubMed

    Al-Batanony, M A; Abdel-Rasoul, G M; Abu-Salem, M A; Al-Ahmar, I A; Al-Badry, A S

    2012-04-01

    Glues are strong, liquid adhesive derived from animal tissues. It has been shown that glue sniffing is associated with demyelinating polyneuropathy. The low molecular weight agents which cause occupational lung disease have generally included the isocyanates exposure to which could result in asthma among workers. Toluene is also used widely in glue and adhesive industry and households where toluene exposure and abuse can occur. To study some respiratory and neurological disorders that may arise in workers in a bone glue factory in Queisna industrial zone, Menoufyia governorate, Egypt. In a historical cohort study, the exposed participants (n = 50) were recruited from workers in a bone glue factory in Queisna industrial zone, Menoufyia governorate. The unexposed group was selected from workers' relatives who had never worked in glue industry. All participants completed a pre-designed questionnaire on personal and occupational histories. Pulmonary function tests as well as electromyography (EMG) were performed for all participants. Urinary hippuric acid was also measure in all participants. The prevalence of cough, asthmatic attacks and paresthesia were significantly higher among exposed than unexposed participants. Abnormal spirometric measurements (particularly towards obstruction), abnormal EMG and positive urinary hippuric acid were significantly more prevalent among exposed than unexposed group. Spirometry and EMG should be included in the periodic medical examination for exposed workers for early detection of respiratory and neurological disorders. Urinary hippuric acid could be a useful indicator of the nerve conduction abnormalities and should be measured periodically for these workers.

  16. Rescue N-butyl-2 cyanoacrylate embolectomy using a Solitaire FR device after venous glue migration during arteriovenous malformation embolization: technical note.

    PubMed

    Fahed, Robert; Clarençon, Frédéric; Sourour, Nader-Antoine; Chauvet, Dorian; Le Jean, Lise; Chiras, Jacques; Di Maria, Federico

    2016-07-01

    One of the procedural risks in arteriovenous malformation (AVM) embolization is possible migration of the embolic agent into the venous drainage with an incomplete nidus occlusion, which may lead to severe hemorrhagic complications. This report presents the case of a 29-year-old man who presented with a deep intraparenchymal hematoma on the left side secondary to the spontaneous rupture of a claustral AVM. Upon resorption of the hematoma, the patient underwent an initial therapeutic session of N-butyl-2 cyanoacrylate endovascular embolization, with the purpose of reducing the AVM volume and flow before performing Gamma Knife radiosurgery. After glue injection into one of the arterial feeders, the control angiography showed a partial migration of the glue cast into the straight sinus, with most of the nidus still visible. Because of the bleeding risk due to possible venous hypertension, it was decided to try to retrieve the glue from the vein by using a stent retriever via jugular access. This maneuver allowed a nearly complete removal of the glue cast, thereby restoring normal venous flow drainage. The patient showed no clinical worsening after the procedure. To the authors' knowledge, this is the first report of the use of the Solitaire FR device as a rescue glue retriever. This method should be considered by physicians in cases of unintended glue migration into the venous circulation during AVM embolization.

  17. Internal fabrics in magmatic plutons emplaced in extended brittle crust - insight from analogue models with AMS (Anisotropy of Magnetic Susceptibility)

    NASA Astrophysics Data System (ADS)

    Mirzaei, Masoud; Zavada, Prokop; Machek, Matej; Roxerova, Zuzana

    2016-04-01

    Magma emplacement in extended brittle crust was simulated by injecting plaster of Paris (magma) into a large sandbox with central deformable rubber sheet. Analog magma is during the experiments injected through small circular inlet cut in the center of the elastic sheet. Injection force oscillation during the steadily evacuating analog magma was recorded during the experiments and regularly showed 3-4 increases followed by a quick drop. The recorded oscillation amplitude is largest for static injection without extension of the sandbox, which formed a columnar body with concentric and zonal internal fabric. Experiments including normal or oblique 20% extension resulted in along rift axis elongated oblate ellipsoidal pluton with rift parallel ridges in the top part of the pluton. Inspection of horizontal profiles show bone-shaped internal zoning patterns limited by conjugate sets of shear zones. Orientation of these internal shear zones is correlated with the sand-clock fault pattern developed in the overburden sand pack. Another set of shear zones parallel with the long axes of the plutons (rift axis) are associated with successive emplacement of distinct plaster pulses during the buildup of the entire body. The innermost lastly emplaced pulses of plaster display weak vertical magnetic fabrics with vertical lineations, while the outer shells of already emplaced plaster reveal stronger and margin parallel oblate magnetic fabrics with subhorizontal lineations. We interpret the vertical innermost fabrics as a result of active ascent of plaster from the injection inlet, while the fabrics in the outer zones likely reflect push due to inflation of the inner domain reflected in the reworking of the magnetic fabric.

  18. Measurements using orthodontic analysis software on digital models obtained by 3D scans of plaster casts : Intrarater reliability and validity.

    PubMed

    Czarnota, Judith; Hey, Jeremias; Fuhrmann, Robert

    2016-01-01

    The purpose of this work was to determine the reliability and validity of measurements performed on digital models with a desktop scanner and analysis software in comparison with measurements performed manually on conventional plaster casts. A total of 20 pairs of plaster casts reflecting the intraoral conditions of 20 fully dentate individuals were digitized using a three-dimensional scanner (D700; 3Shape). A series of defined parameters were measured both on the resultant digital models with analysis software (Ortho Analyzer; 3Shape) and on the original plaster casts with a digital caliper (Digimatic CD-15DCX; Mitutoyo). Both measurement series were repeated twice and analyzed for intrarater reliability based on intraclass correlation coefficients (ICCs). The results from the digital models were evaluated for their validity against the casts by calculating mean-value differences and associated 95 % limits of agreement (Bland-Altman method). Statistically significant differences were identified via a paired t test. Significant differences were obtained for 16 of 24 tooth-width measurements, for 2 of 5 sites of contact-point displacement in the mandibular anterior segment, for overbite, for maxillary intermolar distance, for Little's irregularity index, and for the summation indices of maxillary and mandibular incisor width. Overall, however, both the mean differences between the results obtained on the digital models versus on the plaster casts and the dispersion ranges associated with these differences suggest that the deviations incurred by the digital measuring technique are not clinically significant. Digital models are adequately reproducible and valid to be employed for routine measurements in orthodontic practice.

  19. Traditional Glue, Adhesive and Poison Used for Composite Weapons by Ju/'hoan San in Nyae Nyae, Namibia. Implications for the Evolution of Hunting Equipment in Prehistory.

    PubMed

    Wadley, Lyn; Trower, Gary; Backwell, Lucinda; d'Errico, Francesco

    2015-01-01

    Ju/'hoan hunters from Nyae Nyae, near Tsumkwe in Namibia, demonstrate the manufacture of three fixative pastes made from plant extracts, and poison made from grubs and plant extracts. Ammocharis coranica and Terminalia sericea produce simple glue. Ozoroa schinzii latex mixed with carbonized Aristeda adscensionis grass is a compound adhesive. Composite poison is made from Chrysomelid grub viscera mixed with salivary extracts of Acacia mellifera inner bark and the tuber sap of Asparagus exuvialis. In order to document potential variability in the chaîne opératoire, and to eliminate inherent biases associated with unique observations, we studied manufacturing processes in three separate Nyae Nyae villages. Although there are methodological similarities in the Nyae Nyae area, we observed a few differences in contemporary traditions of poison manufacture. For example, some hunters make powder from Asparagus exuvialis tuber sap by boiling, reducing, hardening and grinding it, while others simply use heated sap. The Ju/'hoan hunting kit provides insights for archaeologists, but we must exercise caution when looking for continuity between prehistoric and historical technical systems. Some traditions have been lost to modern hunters, while others are new. We should also expect variability in the Stone Age because of geographically restricted resources. Simple glue, compound adhesive, and poison recipes identified in the Stone Age have no modern equivalents. By about 60,000 years ago at Diepkloof, simple glue was used for hafting tools, but at similarly-aged Sibudu there are recipes that combine red ochre powder with plant and/or animal ingredients. At Border Cave, novel poisons and compound adhesives were used in the Early Later Stone Age. It is possible that the complexity that we record in the manufacture of fixative pastes and poison used by Ju/'hoan hunters represents a hafting system both similar to and different from that observed at the Stone Age sites of Diepkloof, Sibudu, and Border Cave.

  20. The management of amputations of the leg using a new rigid foam plaster for prosthetic fitting.

    PubMed

    Hölter, W; Echterhoff, M; Blömer, A; Verfürden, H

    1980-01-01

    This paper describes the use of a rigid polyurethane foam to construct a stump socket for immediate or early prosthetic fitting in 15 patients with amputation through the leg. The foam plaster is poured into a prepared cotton sleeve, with a zip incorporated, and rolled out to a layer 4 mm thick. The filled sleeve is put around the stump and the zip closed, moulding the sleeve firmly to the stump. The closed sleeve hardens into a rigid polyurethane shell within 20 min. Aferwards the skeletal prosthetic components are fixed with the same rigid foam. The polyurethane foam socket is quickly and cleanly prepared, only one third of the weight of a plaster of Paris cast and is easily removed by means of the zip, allowing access to the stump.

  1. Hypokalemic muscular paralysis causing acute respiratory failure due to rhabdomyolysis with renal tubular acidosis in a chronic glue sniffer.

    PubMed

    Kao, K C; Tsai, Y H; Lin, M C; Huang, C C; Tsao, C Y; Chen, Y C

    2000-01-01

    A 34-year-old male was admitted to the emergency department with the development of quadriparesis and respiratory failure due to hypokalemia after prolonged glue sniffing. The patient was subsequently given mechanical ventilatory support for respiratory failure. He was weaned from the ventilator 4 days later after potassium replacement. Toluene is an aromatic hydrocarbon found in glues, cements, and solvents. It is known to be toxic to the nervous system, hematopoietic system, and causes acid-base and electrolyte disorders. Acute respiratory failure with hypokalemia and rhabdomyolysis with acute renal failure should be considered as potential events in a protracted glue sniffing.

  2. Prosthesis Material

    NASA Technical Reports Server (NTRS)

    1995-01-01

    In this photograph, Sandra Rossi user her NASA-developed prosthesis for the first time. Derived from foam insulation technology used to protect the Space Shuttle External Tank from excessive heat, FAB/CAD, a subsidiary of the Harshberger Prosthetic and Orthotic Center, utilized the technology to replace the heavy, fragile plaster they used to produce master molds for prosthetics. The new material was lighter, cheaper and easier to manufacture than plaster, resulting in lower costs to the customer.

  3. Effectiveness of Fibrin Glue in Adherence of Skin Graft.

    PubMed

    Reddy, Konda Sireesha; Chittoria, Ravi Kumar; Babu, Preethitha; Marimuthu, Senthil Kumaran; Kumar, Sudhanva Hemanth; Subbarayan, Elan Kumar; Chavan, Vinayak; Mohapatra, Devi Prasad; Sivakumar, Dinesh Kumar; Friji, M T

    2017-01-01

    Graft fixation is important for graft take. Fibrin glue has been proposed as an ideal material, because of its human origin and it provides firm adhesion in seconds or minutes. To evaluate the efficiency of fibrin glue, in increasing the take of skin graft. Assessment includes surgical time taken for graft fixation, haematoma/seroma formation, engraftment and wound closure by day 14. The study is an observational prospective study conducted in the Department of Plastic Surgery, Jawaharlal Institute of Postgraduate Medical Education and Research, Puducherry, from January 2016 to June 2016. Sixteen patients who underwent split skin grafting were assessed during the study period. Fibrin glue was used on the recipient bed before grafting. Better haemostasis and graft adhesion, with a significant reduction of surgical time, were noted. The safety profile of fibrin glue was excellent as indicated by the lack of any related serious adverse experiences. These findings demonstrate that it is safe and effective for attachment of skin grafts, with outcomes at least as good as conventional methods.

  4. Results of fibrin glue application therapy in testicular hydrocele.

    PubMed

    Sirpa, A; Martti, A O

    1998-01-01

    Nine patients, mean age 55 years, with testicular hydroceles, were treated by aspiration and two-component fibrin glue injection. One patient was treated twice. The glue contains 70-110 mg fibrinogen and 500 IU human thrombin in 0.5- and 2-ml injections, respectively (Tisseel duo quick, Immune AB). The smaller glue volume was used in 4 cases and the larger volume in 6 cases. The average volume of hydrocele fluid was 77 (range 60-120) ml. Treatment caused no pain or discomfort other than puncture of the skin and no pain-relieving medication was required afterwards. In this series there were no infections but one conservatively treated hematoma. The hydrocele of that patient disappeared. Although the hydroceles recurred in 9 cases during the mean follow-up of 3.5 months, in 2 patients the hydroceles were clinically smaller than the original one and symptoms were milder subjectively. Our findings suggest that fibrin-adhesive glue is not sufficiently effective in treatment of testicular hydroceles.

  5. Composition Formulas of Inorganic Compounds in Terms of Cluster Plus Glue Atom Model.

    PubMed

    Ma, Yanping; Dong, Dandan; Wu, Aimin; Dong, Chuang

    2018-01-16

    The present paper attempts to identify the molecule-like structural units in inorganic compounds, by applying the so-called "cluster plus glue atom model". This model, originating from metallic glasses and quasi-crystals, describes any structure in terms of a nearest-neighbor cluster and a few outer-shell glue atoms, expressed in the cluster formula [cluster](glue atoms). Similar to the case for normal molecules where the charge transfer occurs within the molecule to meet the commonly known octet electron rule, the octet state is reached after matching the nearest-neighbor cluster with certain outer-shell glue atoms. These kinds of structural units contain information on local atomic configuration, chemical composition, and electron numbers, just as for normal molecules. It is shown that the formulas of typical inorganic compounds, such as fluorides, oxides, and nitrides, satisfy a similar octet electron rule, with the total number of valence electrons per unit formula being multiples of eight.

  6. Effect of complexation conditions on microcapsulation of Lactobacillus acidophilus in xanthan-chitosan polyelectrolyte complex gels.

    PubMed

    Chen, He; Song, Yajuan; Liu, Nina; Wan, Hongchang; Shu, Guowei; Liao, Na

    2015-01-01

    Lactobacillus acidophilus has become increasingly popular because of their beneficial effects on health of their host, and are called proboscis. In order to exert beneficial effects for probiotics, they must be able to tolerate the acidic conditions of the stomach environment and the bile in the small intestine. Microencapsulated form has received reasonable attention, since it can protect probiotic organisms against an unfavourable environment, and to allow their release in a viable and metabolically active state in the intestine. The aim of this study was to investigate some factores, such as chitosan solution pH and concentration, xanthan concentration, cell suspension-xanthan ratio, mixed bacteria glue liquid-chitosan ratio, which impacted the process of microencapsulation of L. acidophilus. In this study, L. acidophilus was immobilized with xanthan⁄chitosan gel using extrusion method. The viable counts and encapsulation yield of L. acidophilus encapsulated in different chitosan solution pH (4.5, 5, 5.5 and 6), in different chitosan concentration (0.5%, 0.7%, 0.9% and 1.1%), in different xanthan concentration (0.5%, 0.7%, 0.9% and 1.1%), in different cell suspension-xanthan ratios (1:5, 1:10, 1:15 and 1:20), in different mixed bacteria glue liquid-chitosan ratios (1:3, 1:4, 1:5 and 1:6), have been investigated by single factor experiment method. The optimum conditions of microencapsulated L. acidophilus have been observed. The optimum chitosan solution pH for L. acidophilus was 5.5; the optimum chitosan concentration was 0.9%; the optimum xanthan concentration was 0.7%; the optimum cell suspension-xanthan ratio was 1:10; the optimum mixed bacteria glue liquid-chitosan ratio was 1:3. These results will be helpful to further optimize the process of L. acidophilus microencapsulation, and provide reference for obtaining higher viable counts and entrapped yield of L. acidophilus microcapsules.

  7. Compositional and quantitative microtextural characterization of historic paintings by micro-X-ray diffraction and Raman microscopy.

    PubMed

    Romero-Pastor, Julia; Duran, Adrian; Rodríguez-Navarro, Alejandro Basilio; Van Grieken, René; Cardell, Carolina

    2011-11-15

    This work shows the benefits of characterizing historic paintings via compositional and microtextural data from micro-X-ray diffraction (μ-XRD) combined with molecular information acquired with Raman microscopy (RM) along depth profiles in paint stratigraphies. The novel approach was applied to identify inorganic and organic components from paintings placed at the 14th century Islamic University-Madrasah Yusufiyya-in Granada (Spain), the only Islamic University still standing from the time of Al-Andalus (Islamic Spain). The use of μ-XRD to obtain quantitative microtextural information of crystalline phases provided by two-dimensional diffraction patterns to recognize pigments nature and manufacture, and decay processes in complex paint cross sections, has not been reported yet. A simple Nasrid (14th century) palette made of gypsum, vermilion, and azurite mixed with glue was identified in polychromed stuccos. Here also a Christian intervention was found via the use of smalt, barite, hematite, Brunswick green and gold; oil was the binding media employed. On mural paintings and wood ceilings, more complex palettes dated to the 19th century were found, made of gypsum, anhydrite, barite, dolomite, calcite, lead white, hematite, minium, synthetic ultramarine blue, and black carbon. The identified binders were glue, egg yolk, and oil.

  8. Geometrical tile design for complex neighborhoods.

    PubMed

    Czeizler, Eugen; Kari, Lila

    2009-01-01

    Recent research has showed that tile systems are one of the most suitable theoretical frameworks for the spatial study and modeling of self-assembly processes, such as the formation of DNA and protein oligomeric structures. A Wang tile is a unit square, with glues on its edges, attaching to other tiles and forming larger and larger structures. Although quite intuitive, the idea of glues placed on the edges of a tile is not always natural for simulating the interactions occurring in some real systems. For example, when considering protein self-assembly, the shape of a protein is the main determinant of its functions and its interactions with other proteins. Our goal is to use geometric tiles, i.e., square tiles with geometrical protrusions on their edges, for simulating tiled paths (zippers) with complex neighborhoods, by ribbons of geometric tiles with simple, local neighborhoods. This paper is a step toward solving the general case of an arbitrary neighborhood, by proposing geometric tile designs that solve the case of a "tall" von Neumann neighborhood, the case of the f-shaped neighborhood, and the case of a 3 x 5 "filled" rectangular neighborhood. The techniques can be combined and generalized to solve the problem in the case of any neighborhood, centered at the tile of reference, and included in a 3 x (2k + 1) rectangle.

  9. Successful Endoscopic Management of Non-Healing Perforated Duodenal Ulcer with Polyglycolic Acid Sheet and Fibrin Glue.

    PubMed

    Mishiro, Tsuyoshi; Shibagaki, Kotaro; Matsuda, Kayo; Fukuyama, Chika; Okada, Mayumi; Mikami, Hironobu; Izumi, Daisuke; Yamashita, Noritsugu; Okimoto, Eiko; Fukuda, Naoki; Aimi, Masahito; Fukuba, Nobuhiko; Oshima, Naoki; Takanashi, Toshihiro; Matsubara, Takeshi; Ishimura, Norihisa; Ishihara, Shunji; Kinoshita, Yoshikazu

    2016-08-01

    In recent years, treatment techniques in which polyglycolic acid sheets are applied to various situations with fibrin glue have exhibited great clinical potential, and previous studies have reported safety and efficacy. We describe closure of a non-healing perforated duodenal ulcer with the use of a polyglycolic acid sheet and fibrin glue in an elderly patient who was not a candidate for surgery.

  10. [Emission of organic substances from chip-boards].

    PubMed

    Deppe, H J

    1982-01-01

    A relatively small number of investigations on emissions of organic substances from chip-board is available up to now. The emissions known to date are caused by glues or other additives rather than by the wood itself. As concerns aminoplast glues (urea-formaldehyde or melamine-formaldehyde resins) the most important point of public interest has been the off-gassing of formaldehyde from chip-board. Chip-board with phenol-formaldehyde glues has been known in some cases to give off phenol. The formation of diamino diphenyl methane from isocyanate glues is still a matter of discussion. A further source for possible emissions are wood and fire protectives which are added during the manufacturing process. Finally, coating of chip-board may lead to emissions of organic substances. The lack of adequate detection methods has so far delayed the treatment of questions in relation to emissions from chip-board. Even now, there are numerous problems in this field especially when investigating isocyanate glues. Problems in relation to the origin of emissions due to the kind of glue used and the manufacturing process are discussed, and proposals are made how to solve some of these problems. The question of the health risk is dealt with from the view-point of the civil engineer and in an general economic context.

  11. Application of COMPONT Medical Adhesive Glue for Tension-Reduced Duraplasty in Decompressive Craniotomy

    PubMed Central

    Zhou, Yujia; Wang, Gesheng; Liu, Jialin; Du, Yong; Wang, Lei; Wang, Xiaoyong

    2016-01-01

    Background The aim of this study was to evaluate the application of medical adhesive glue for tension-reduced duraplasty in decompressive craniotomy. Material/Methods A total of 56 cases were enrolled for this study from Jan 2013 to May 2015. All patients underwent decompressive craniotomy and the dura was repaired in all of them with tension-reduced duraplasty using the COMPONT medical adhesive to glue artificial dura together. The postoperative complications and the healing of dura mater were observed and recorded. Results No wound infection, epidural or subdural hematoma, cerebrospinal fluid leakage, or other complications associated with the procedure occurred, and there were no allergic reactions to the COMPONT medical adhesive glue. The second-phase surgery of cranioplasty was performed at 3 to 6 months after the decompressive craniotomy in 32 out of the 56 cases. During the cranioplasty we observed no adherence of the artificial dura mater patch to the skin flap, no residual COMPONT glue, or hydropic or contracture change of tissue at the surgical sites. Additionally, no defect or weakening of the adherence between the artificial dura mater patch and the self dura matter occurred. Conclusions COMPONT medical adhesive glue is a safe and reliable tool for tension-reduced duraplasty in decompressive craniotomy. PMID:27752035

  12. Molecular glues for manipulating enzymes: trypsin inhibition by benzamidine-conjugated molecular glues† †Electronic supplementary information (ESI) available: Synthesis of TEG–BA, Gluen–BA, mGluen–BA and Gluen–Ph; 1H NMR, 13C NMR, MALDI-TOF MS, electronic absorption, and CD spectra; zeta potential distributions; SLS plots; DLS histograms; and related experimental procedures. See DOI: 10.1039/c5sc00524h Click here for additional data file.

    PubMed Central

    Mogaki, Rina

    2015-01-01

    Water-soluble bioadhesive polymers bearing multiple guanidinium ion (Gu+) pendants at their side-chain termini (Gluen–BA, n = 10 and 29) that were conjugated with benzamidine (BA) as a trypsin inhibitor were developed. The Gluen–BA molecules are supposed to adhere to oxyanionic regions of the trypsin surface, even in buffer, via a multivalent Gu+/oxyanion salt-bridge interaction, such that their BA group properly blocks the substrate-binding site. In fact, Glue10–BA and Glue29–BA exhibited 35- and 200-fold higher affinities for trypsin, respectively, than a BA derivative without the glue moiety (TEG–BA). Most importantly, Glue10–BA inhibited the protease activity of trypsin 13-fold more than TEG–BA. In sharp contrast, mGlue27–BA, which bears 27 Gu+ units along the main chain and has a 5-fold higher affinity than TEG–BA for trypsin, was inferior even to TEG–BA for trypsin inhibition. PMID:28706668

  13. Evaluating the use of fibrin glue for sealing low-output enterocutaneous fistulas: study protocol for a randomized controlled trial.

    PubMed

    Wu, Xiuwen; Ren, Jianan; Wang, Gefei; Wang, Jianzhong; Wang, Feng; Fan, Yueping; Li, Yuanxin; Han, Gang; Zhou, Yanbing; Song, Xiaofei; Quan, Bin; Yao, Min; Li, Jieshou

    2015-10-07

    The management of an enterocutaneous fistula poses a significant challenge to surgeons and is often associated with a costly hospital stay and long-term discomfort. The use of fibrin glue in the fistula tract has been shown to promote closure of low output enterocutaneous fistulas. Our previous nonrandomized study demonstrated that autologous platelet-rich fibrin glue treatment significantly decreased time to fistula closure and promoted closure rates. However, there are several limitations in the study, which may lead to bias in our conclusion. Thus, a multicenter, randomized, controlled clinical trial is required. The study is designed as a randomized, open-label, three-arm, multicenter study in nine Chinese academic hospitals for evaluating the efficacy and safety of fibrin glue for sealing low-output fistulas. An established number of 171 fistula patients will undergo prospective random assignment to autologous fibrin glue, commercial porcine fibrin sealants or drainage cessation (1:1:1). The primary endpoint is fistula closure time (defined as the interval between the day of enrollment and day of fistula closure) during the 14-day treatment period. To our knowledge, this is the first study to evaluate the safety and efficacy of both autologous and commercial fibrin glue sealing for patients with low-output volume fistulas. NCT01828892 . Registration date: April 2013.

  14. Effect of collagen sponge and fibrin glue on bone repair

    PubMed Central

    SANTOS, Thiago de Santana; ABUNA, Rodrigo Paolo Flores; de ALMEIDA, Adriana Luisa Gonçalves; BELOTI, Marcio Mateus; ROSA, Adalberto Luiz

    2015-01-01

    ABSTRACT The ability of hemostatic agents to promote bone repair has been investigated using in vitro and in vivo models but, up to now, the results are inconclusive. Objective In this context, the aim of this study was to compare the potential of bone repair of collagen sponge with fibrin glue in a rat calvarial defect model. Material and Methods Defects of 5 mm in diameter were created in rat calvariae and treated with either collagen sponge or fibrin glue; untreated defects were used as control. At 4 and 8 weeks, histological analysis and micro-CT-based histomorphometry were carried out and data were compared by two-way ANOVA followed by Student-Newman-Keuls test when appropriated (p≤0.05). Results Three-dimensional reconstructions showed increased bone formation in defects treated with either collagen sponge or fibrin glue compared with untreated defects, which was confirmed by the histological analysis. Morphometric parameters indicated the progression of bone formation from 4 to 8 weeks. Additionally, fibrin glue displayed slightly higher bone formation rate when compared with collagen sponge. Conclusion Our results have shown the benefits of using collagen sponge and fibrin glue to promote new bone formation in rat calvarial bone defects, the latter being discreetly more advantageous. PMID:26814464

  15. Adhesive arachnoiditis after percutaneous fibrin glue treatment of a sacral meningeal cyst.

    PubMed

    Hayashi, Kazunori; Nagano, Junji; Hattori, Satoshi

    2014-06-01

    The authors present the case of a 64-year-old woman who was referred for severe sacral pain. She reported that her pain had been longstanding, and had greatly increased after percutaneous fibrin glue placement therapy for a sacral meningeal cyst 2 months earlier at a different hospital. An MRI scan obtained immediately after fibrin glue placement at that hospital suggested that fibrin glue had migrated superiorly into the subarachnoid space from the sacral cyst to the level of L-4. On admission to the authors' institution, physical examination demonstrated no abnormal findings except for perianal hypesthesia. An MRI study obtained at admission demonstrated a cystic lesion in the peridural space from the level of S-2 to S-4. Inhomogeneous intensity was identified in this region on T2-weighted images. Because the cauda equina and nerve roots appeared to be compressed by the lesion, total cyst excision was performed. The cyst cavity was filled with fluid that resembled CSF, plus gelatinous material. Histopathological examination revealed that the cyst wall was composed of hyaline connective tissue with some calcification. No nervous tissue or ganglion cells were found in the tissue. The gelatinous material was acellular, and appeared to be degenerated fibrin glue. Sacral pain persisted to some extent after surgery. The authors presumed that migrated fibrin glue caused the development of adhesive arachnoiditis. The risk of adhesive arachnoiditis should be considered when this therapy is planned. Communication between a cyst and the subarachnoid space should be confirmed to be sufficiently narrow to prevent the migration of injected fibrin glue.

  16. Amplitude of Glottal Mucosal Wave After Vocal Fold Microflap With or Without Fibrin Glue.

    PubMed

    González-Herranz, Ramón; Amarillo, Elizabeth; Hernández-García, Estefanía; Montojo Woodeson, José; Plaza-Mayor, Guillermo

    2017-05-01

    The vocal fold microflap technique is the ideal to remove benign vocal fold pathology. Our objective is to compare the amplitudes of the mucosal wave before and after the closure of microflap defect with fibrin glue, and when microflap is left to heal by secondary intention. The present study is a retrospective series, including 32 patients treated by intracordal phonosurgery, with closure of the microflap either with fibrin glue or by healing by secondary intention. They all had both preoperative and 6-month postoperative track records to allow voice analysis, a subjective Voice Handicap Index 10 (VHI-10), and a good image quality strobe. After selecting the patients was found that the mean overall preoperative VHI-10 was 26.6, and improved up to 10.5 after surgery, a statistical differences (P = 0.03). When comparing both groups, with or without fibrin glue, fibrin glue did not improved results in VHI-10. On the contrary, there was a significant difference in the improvement of the open glottal phase after surgery (P = 0.03), showing a much higher improvement when fibrin glue was used. The use of fibrin glue after a vocal fold microflap for advanced pathology, such as sulcus vocalis in pocket, vergeture, or vocal fold scar, increases the amplitude of the mucosal wave of the vocal folds, but does not improve the VHI-10 results in our cohort of female patients. So far, patient-reported outcome shows that healing by secondary intention continues to provide excellent voice results. Copyright © 2017 The Voice Foundation. Published by Elsevier Inc. All rights reserved.

  17. Fibrin glue.

    PubMed

    Brennan, M

    1991-12-01

    Fibrin glue is a topical biological adhesive, the effect of which imitates the final stages of coagulation. The glue consists of a solution of concentrated human fibrinogen which is activated by the addition of bovine thrombin and calcium chloride. The resultant clot aids haemostasis and tissue sealing and is completely absorbed during wound healing without foreign body reaction or extensive fibrosis. The fibrinogen component of fibrin glue can be produced from fresh frozen plasma obtained from single unit donations thereby reducing the risks of transfusion transmitted infections encountered by exposure to pools from large numbers of donors. Methods involving precipitation of fibrinogen by cryoprecipitation, polyethylene glycol or ammonium sulphate have been described and evaluated. The risk of transmission of infection can be further reduced by using plasma from 'accredited donors' who are plasma donors regularly tested for ALT and markers of viral infection or by use of fibrinogen prepared in advance of surgery from autologous blood. The second component, a mixture of thrombin and CaCl2, is quantitatively and qualitatively well defined and commercially available (Armour Pharmaceutical Co., Thrombinar (bovine thrombin]. Thrombin is applied to the operation site simultaneously and in equal volume to the fibrinogen but from a separate syringe. In the UK a commercial heat treated fibrin glue prepared from pooled plasma is available on a doctor/named patient basis (Tisseel, Immuno, Vienna). The haemostatic and adhesive properties of fibrin glue can be employed in virtually every surgical specialty. The usefulness of the glue is particularly well documented in the fields of cardiovascular surgery, ENT and neurosurgery.(ABSTRACT TRUNCATED AT 250 WORDS)

  18. Porcine wound healing in full-thickness skin defects using Integra™ with and without fibrin glue with keratinocytes

    PubMed Central

    Melendez, Mark M; Martinez, Rodrigo R; Dagum, Alexander B; McClain, Steve A; Simon, Marcia; Sobanko, Joseph; Zimmerman, Thomas; Wetterau, Meredith; Muller, Douglas; Xu, Xiaoti; Singer, Adam J; Arora, Balvantray

    2008-01-01

    BACKGROUND: An artificial dermal matrix such as Integra (Integra Life Sciences Corporation, USA) provides a wound bed template for vascular and fibrocyte ingrowth as well as collagen remodelling. Dermal repair leads to epidermal and basement membrane regeneration. Burn wounds in particular have been shown to benefit from Integra by enhanced wound healing. OBJECTIVE: To evaluate the effect of fibrin glue to modify the integration of Integra in large excised cutaneous wounds. It was hypothesized that applying fibrin glue on a wound bed would reduce the time needed for matrix vascularization and incorporation of Integra and take of the cultured keratinocytes. METHODS: Four separate full-thickness wounds were created on the dorsum of two swine. Wound beds were randomly assigned to either application of fibrin glue or no application of fibrin glue before application of Integra. Full-thickness biopsies were performed at days 7, 14, 21, 29 and 35. On day 21, keratinocytes were applied either as sheets or aerosolized fibrin glue suspension. RESULTS: Histological analysis revealed a wave of inflammatory cells and early granulation tissue ingrowth into the Integra from the fascia below on day 7. Only this initial phase was augmented by application of fibrin glue to the wound bed. By day 14, most and by day 21, all of the Integra thickness was incorporated. Accelerated dermal repair proceeded from the base with new collagen deposition in Integra spaces. There was no evidence of keratinocyte engraftment, although re-epithelialization occurred at wound edges extending onto the incorporated Integra. CONCLUSIONS: It appears there is an acceleration of early phase (day 7 to day 21) dermal incorporation with fibrin glue application to the wound bed, perhaps secondary to increased cellular migration. Day 21 appears to be too early to apply cultured keratinocytes either as sheets or aerosolized suspension. PMID:19721792

  19. Biomechanical and histologic evaluation of two application forms of surgical glue for mesh fixation to the abdominal wall.

    PubMed

    Ortillés, Á; Pascual, G; Peña, E; Rodríguez, M; Pérez-Köhler, B; Mesa-Ciller, C; Calvo, B; Bellón, J M

    2017-11-01

    The use of an adhesive for mesh fixation in hernia repair reduces chronic pain and minimizes tissue damage in the patient. This study was designed to assess the adhesive properties of a medium-chain (n-butyl) cyanoacrylate glue applied as drops or as a spray in a biomechanical and histologic study. Both forms of glue application were compared to the use of simple-loose or continuous-running polypropylene sutures for mesh fixation. Eighteen adult New Zealand White rabbits were used. For mechanical tests in an ex vivo and in vivo study, patches of polypropylene mesh were fixed to an excised fragment of healthy abdominal tissue or used to repair a partial abdominal wall defect in the rabbit respectively. Depending on the fixation method used, four groups of 12 implants each or 10 implants each respectively for the ex vivo and in vivo studies were established: Glue-Drops, Glue-Spray, Suture-Simple and Suture-Continuous. Biomechanical resistance in the ex vivo implants was tested five minutes after mesh fixation. In vivo implants for biomechanical and histologic assessment were collected at 14 days postimplant. In the ex vivo study, the continuous suture implants showed the highest failure sample tension, while the implants fixed with glue showed lower failure sample tension values. However, the simple and continuous suture implants returned the highest stretch values. In the in vivo implants, failure sample tension values were similar among groups while the implants fixed with a continuous running suture had the higher stretch values, and the glue-fixed implants the lower stretch values. All meshes showed good tissue integration within the host tissue regardless of the fixation method used. Our histologic study revealed the generation of a denser, more mature repair tissue when the cyanoacrylate glue was applied as a spray rather than as drops. Copyright © 2017 Elsevier Ltd. All rights reserved.

  20. Fabrication of complex nanoscale structures on various substrates

    NASA Astrophysics Data System (ADS)

    Han, Kang-Soo; Hong, Sung-Hoon; Lee, Heon

    2007-09-01

    Polymer based complex nanoscale structures were fabricated and transferred to various substrates using reverse nanoimprint lithography. To facilitate the fabrication and transference of the large area of the nanostructured layer to the substrates, a water-soluble polyvinyl alcohol mold was used. After generation and transference of the nanostructured layer, the polyvinyl alcohol mold was removed by dissolving in water. A residue-free, UV-curable, glue layer was formulated and used to bond the nanostructured layer onto the substrates. As a result, nanometer scale patterned polymer layers were bonded to various substrates and three-dimensional nanostructures were also fabricated by stacking of the layers.

  1. Measurement of radiation damage on an epoxy-based optical glue

    NASA Astrophysics Data System (ADS)

    Huang, H. C.; Peng, K. C.; Sahu, S. K.; Ueno, K.; Chang, Y. H.; Wang, C. H.; Hou, W. S.

    1997-02-01

    We measured the radiation damage on an optical glue called Eccobond-24, which is a candidate for CsI and BGO crystal calorimeters of the BELLE detector of the KEK B-factory. Absorption spectrophotometry in the range 300-800 nm was used to monitor the radiation damage. The maximum equivalent dose was 1.64 Mrad. The glue shows effects of damage, but is acceptable for the radiation level in the above-mentioned experiment.

  2. Therapeutic ureteral occlusion with Ifabond cyanoacrylate glue: an interesting solution.

    PubMed

    Oderda, Marco; Lacquaniti, Sergio; Fraire, Flavio; Antolini, Jacopo; Camilli, Marco; Mandras, Roberto; Puccetti, Luca; Varvello, Francesco; Fasolis, Giuseppe

    2017-08-01

    The aim of this study was to present a novel approach for complete and permanent ureteral occlusion using a percutaneous injection of Ifabond cyanoacrylate glue. We describe in detail all the steps of our surgery, performed on a 79-year-old patient with urinary leakage from ureteral stump following radical cystectomy. N-hexyl-cyanoacrylate glue (Ifabond) was used to occlude the distal ureter and solve the leakage. Our approach was successful, sparing our already frail patient further surgical procedures. Six months pyelography confirmed the complete ureteral blockage with absence of extravasation. In complicated scenarios with urinary leakages and frail patients, synthetic glues such as Ifabond might represent an interesting therapeutic option to solve the fistulas, leading to durable success with a minimally invasive approach.

  3. The GlueX DIRC project

    DOE PAGES

    Stevens, J.; Barbosa, F.; Bessuille, J.; ...

    2016-07-20

    Here, the GlueX experiment was designed to search for and study the pattern of gluonic excitations in the meson spectrum produced through photoproduction reactions at a new tagged photon beam facility in Hall D at Jefferson Laboratory. The particle identification capabilities of the GlueX experiment will be enhanced by constructing a DIRC (Detection of Internally Reflected Cherenkov light) detector, utilizing components of the decommissioned BaBar DIRC. The DIRC will allow systematic studies of kaon final states that are essential for inferring the quark flavor content of both hybrid and conventional mesons. In this contribution, the design for the GlueX DIRCmore » will be discussed including new expansion volumes, read out with MaPMTs, that are currently under development.« less

  4. Brainlab: A Python Toolkit to Aid in the Design, Simulation, and Analysis of Spiking Neural Networks with the NeoCortical Simulator.

    PubMed

    Drewes, Rich; Zou, Quan; Goodman, Philip H

    2009-01-01

    Neuroscience modeling experiments often involve multiple complex neural network and cell model variants, complex input stimuli and input protocols, followed by complex data analysis. Coordinating all this complexity becomes a central difficulty for the experimenter. The Python programming language, along with its extensive library packages, has emerged as a leading "glue" tool for managing all sorts of complex programmatic tasks. This paper describes a toolkit called Brainlab, written in Python, that leverages Python's strengths for the task of managing the general complexity of neuroscience modeling experiments. Brainlab was also designed to overcome the major difficulties of working with the NCS (NeoCortical Simulator) environment in particular. Brainlab is an integrated model-building, experimentation, and data analysis environment for the powerful parallel spiking neural network simulator system NCS.

  5. General engineering specifications for 6000 tpd SRC-I Demonstration Plant

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    This volume contains specifications for architectural features of buildings for the SRC-1 Demonstration Plant: skylights, ventilators, sealants, doors, mirrors, furring and lathing, gypsum plaster, lightweight plaster, wallboard, ceramic tile, acoustic ceiling systems, resilient flooring, carpeting, brick flooring, architectural painting, vinyl wall covering, chalkboards, tackboards, toilets, access flooring, lockers, partitions, washroom accessories, unit kitchens, dock levels, seals, shelters, custom casework, auditorium seats, drapery tacks, prefabricated buildings, stairs, elevators, shelves, etc. (LTN).

  6. Benefit from NASA

    NASA Image and Video Library

    1995-01-01

    In this photograph, Sandra Rossi user her NASA-developed prosthesis for the first time. Derived from foam insulation technology used to protect the Space Shuttle External Tank from excessive heat, FAB/CAD, a subsidiary of the Harshberger Prosthetic and Orthotic Center, utilized the technology to replace the heavy, fragile plaster they used to produce master molds for prosthetics. The new material was lighter, cheaper and easier to manufacture than plaster, resulting in lower costs to the customer.

  7. Benefit from NASA

    NASA Image and Video Library

    1995-01-01

    In this photograph, James Carden uses a NASA-developed prosthesis to moved planks around his home. Derived from foam insulation technology used to protect the Space Shuttle External Tank from excessive heat, FAB/CAD, a subsidiary of the Harshberger Prosthetic and Orthotic Center, utilized the technology to replace the heavy, fragile plaster they used to produce master molds for prosthetics. The new material was lighter, cheaper and easier to manufacture than plaster, resulting in lower costs to the customer.

  8. Benefit from NASA

    NASA Image and Video Library

    2004-04-15

    In this photograph, Amputee Amie Bradly uses a NASA-developed prosthesis to paint her fingernails. Derived from foam insulation technology used to protect the Space Shuttle External Tank from excessive heat, FAB/CAD, a subsidiary of the Harshberger Prosthetic and Orthotic Center, utilized the technology to replace the heavy, fragile plaster they used to produce master molds for prosthetics. The new material was lighter, cheaper and easier to manufacture than plaster, resulting in lower costs to the customer.

  9. Prosthesis Material

    NASA Technical Reports Server (NTRS)

    2004-01-01

    In this photograph, Amputee Amie Bradly uses a NASA-developed prosthesis to paint her fingernails. Derived from foam insulation technology used to protect the Space Shuttle External Tank from excessive heat, FAB/CAD, a subsidiary of the Harshberger Prosthetic and Orthotic Center, utilized the technology to replace the heavy, fragile plaster they used to produce master molds for prosthetics. The new material was lighter, cheaper and easier to manufacture than plaster, resulting in lower costs to the customer.

  10. Prosthesis Material

    NASA Technical Reports Server (NTRS)

    1995-01-01

    In this photograph, James Carden uses a NASA-developed prosthesis to moved planks around his home. Derived from foam insulation technology used to protect the Space Shuttle External Tank from excessive heat, FAB/CAD, a subsidiary of the Harshberger Prosthetic and Orthotic Center, utilized the technology to replace the heavy, fragile plaster they used to produce master molds for prosthetics. The new material was lighter, cheaper and easier to manufacture than plaster, resulting in lower costs to the customer.

  11. Comparison of different uncertainty techniques in urban stormwater quantity and quality modelling.

    PubMed

    Dotto, Cintia B S; Mannina, Giorgio; Kleidorfer, Manfred; Vezzaro, Luca; Henrichs, Malte; McCarthy, David T; Freni, Gabriele; Rauch, Wolfgang; Deletic, Ana

    2012-05-15

    Urban drainage models are important tools used by both practitioners and scientists in the field of stormwater management. These models are often conceptual and usually require calibration using local datasets. The quantification of the uncertainty associated with the models is a must, although it is rarely practiced. The International Working Group on Data and Models, which works under the IWA/IAHR Joint Committee on Urban Drainage, has been working on the development of a framework for defining and assessing uncertainties in the field of urban drainage modelling. A part of that work is the assessment and comparison of different techniques generally used in the uncertainty assessment of the parameters of water models. This paper compares a number of these techniques: the Generalized Likelihood Uncertainty Estimation (GLUE), the Shuffled Complex Evolution Metropolis algorithm (SCEM-UA), an approach based on a multi-objective auto-calibration (a multialgorithm, genetically adaptive multi-objective method, AMALGAM) and a Bayesian approach based on a simplified Markov Chain Monte Carlo method (implemented in the software MICA). To allow a meaningful comparison among the different uncertainty techniques, common criteria have been set for the likelihood formulation, defining the number of simulations, and the measure of uncertainty bounds. Moreover, all the uncertainty techniques were implemented for the same case study, in which the same stormwater quantity and quality model was used alongside the same dataset. The comparison results for a well-posed rainfall/runoff model showed that the four methods provide similar probability distributions of model parameters, and model prediction intervals. For ill-posed water quality model the differences between the results were much wider; and the paper provides the specific advantages and disadvantages of each method. In relation to computational efficiency (i.e. number of iterations required to generate the probability distribution of parameters), it was found that SCEM-UA and AMALGAM produce results quicker than GLUE in terms of required number of simulations. However, GLUE requires the lowest modelling skills and is easy to implement. All non-Bayesian methods have problems with the way they accept behavioural parameter sets, e.g. GLUE, SCEM-UA and AMALGAM have subjective acceptance thresholds, while MICA has usually problem with its hypothesis on normality of residuals. It is concluded that modellers should select the method which is most suitable for the system they are modelling (e.g. complexity of the model's structure including the number of parameters), their skill/knowledge level, the available information, and the purpose of their study. Copyright © 2012 Elsevier Ltd. All rights reserved.

  12. Photocurable surgical tissue adhesive glues composed of photoreactive gelatin and poly(ethylene glycol) diacrylate.

    PubMed

    Nakayama, Y; Matsuda, T

    1999-01-01

    This article presents a novel photochemically driven surgical tissue adhesive technology using photoreactive gelatins and a water-soluble difunctional macromer (poly(ethylene glycol) diacrylate: PEGDA).The gelatins were partially derivatized with photoreactive groups, such as ultraviolet light (UV)-reactive benzophenone and visible light-reactive xanthene dye (e.g., fluorescein sodium salt, eosin Y, and rose bengal). A series of the prepared photocurable tissue adhesive glues, consisting of the photoreactive gelatin, PEGDA, and a saline solution with or without ascorbic acid as a reducing agent, were viscous solutions under warming, and their effectiveness was evaluated as hemostasis- and anastomosis-aid in cardiovascular surgery. Regardless of the type of photoreactive groups, the irradiation of the photocurable tissue adhesive glues by UV or visible light within 1 min produced water-swollen gels, which had a high adhesive strength to wet collagen film. These were due to the synergistic action of photoreactive group-initiated photo-cross-linking and photograft polymerization. An increase in the irradiation time resulted in increased gel yield and reduced water swellability. A decrease in the molecular weight of PEGDA and an increase in concentration of both gelatin and PEGDA resulted in reduced water swellability and increased tensile and burst strengths of the resultant gels. In rats whose livers were injured with a trephine in laparotomy, the bleeding spots were coated with the photocurable adhesive glue and irradiated through an optical fiber. The coated solution was immediately converted to a swollen gel. The gel was tightly adhered to the liver tissue presumably by interpenetration, and concomitantly hemostasis was completed. The anastomosis treatment with the photocurable glue in the canine abdominal or thoracic aortas incised with a knife resulted in little bleeding under pulsatile flow after declamping. Histological examination showed that the glues photocured on rat liver surfaces were gradually degraded with time in vivo with infiltration of inflammatory cells and connective tissues without necrotic sign in surrounding tissue. In addition, in the laparoscopic surgery, percutaneous delivery of the glue and its in situ photogelation on rat liver surfaces were demonstrated using a specially designed fiberscope. These results indicate that the photocurable glues developed here may serve as a biodegradable tissue adhesive glue usable in cardiovascular surgery and endoscopic surgery. Copyright 1999 John Wiley & Sons, Inc.

  13. Withstand pressure of a simple fibrin glue sealant: experimental study of mimicked sellar reconstruction in extended transsphenoidal surgery.

    PubMed

    Oshino, Satoru; Saitoh, Youichi; Yoshimine, Toshiki

    2010-06-01

    To examine the strength and tolerance of the fibrin glue sealant in a situation of extended transsphenoidal surgery. The withstand pressure of fibrin glue sealant was measured using a simple sellar reconstruction model. A 15-mm diameter hole at the bottom of a 51-cm high cylinder was covered with a Gore-Tex (Gore-Tex, Tokyo, Japan) sheet. A small plate was placed on the center for a brief fixation, and 3 mL of fibrin glue was applied over the entire bottom. Then water was gradually filled in five cylinders, and the water level at leakage was measured as withstand pressures at 10 minutes and 24 hours after sealant application. The stability of the sealant under pressures of 20 and 30 cm H(2)O for 12 hours was also examined. The median initial withstand pressure at 10 minutes was 32 cm H(2)O (n = 5), and was significantly increased to 47.5 cm H(2)O after 24 hours (n = 4). In four of five cylinders, fibrin glue sealants were stable against a pressure of 20 cm H(2)O for 12 hours and 30 cm H(2)O for the next 12 hours. The withstand pressure of simple fibrin glue sealant without other biological reactions could be estimated to be more than 20 cm H(2)O after application, and increased to more than 40 cm H(2)O after 24 hours. These data are practical for neurosurgeons to comprehend the strength and limit of fibrin glue sealant and suggests the importance to control the intracranial pressure to less than 20 cm H(2)O, especially for the first 12 to 24 hours. Copyright © 2010 Elsevier Inc. All rights reserved.

  14. Addressing subjective decision-making inherent in GLUE-based multi-criteria rainfall-runoff model calibration

    NASA Astrophysics Data System (ADS)

    Shafii, Mahyar; Tolson, Bryan; Shawn Matott, L.

    2015-04-01

    GLUE is one of the most commonly used informal methodologies for uncertainty estimation in hydrological modelling. Despite the ease-of-use of GLUE, it involves a number of subjective decisions such as the strategy for identifying the behavioural solutions. This study evaluates the impact of behavioural solution identification strategies in GLUE on the quality of model output uncertainty. Moreover, two new strategies are developed to objectively identify behavioural solutions. The first strategy considers Pareto-based ranking of parameter sets, while the second one is based on ranking the parameter sets based on an aggregated criterion. The proposed strategies, as well as the traditional strategies in the literature, are evaluated with respect to reliability (coverage of observations by the envelope of model outcomes) and sharpness (width of the envelope of model outcomes) in different numerical experiments. These experiments include multi-criteria calibration and uncertainty estimation of three rainfall-runoff models with different number of parameters. To demonstrate the importance of behavioural solution identification strategy more appropriately, GLUE is also compared with two other informal multi-criteria calibration and uncertainty estimation methods (Pareto optimization and DDS-AU). The results show that the model output uncertainty varies with the behavioural solution identification strategy, and furthermore, a robust GLUE implementation would require considering multiple behavioural solution identification strategies and choosing the one that generates the desired balance between sharpness and reliability. The proposed objective strategies prove to be the best options in most of the case studies investigated in this research. Implementing such an approach for a high-dimensional calibration problem enables GLUE to generate robust results in comparison with Pareto optimization and DDS-AU.

  15. Vascularization of conjunctival autografts in pterygium surgery: comparison of fibrin glue with sutures.

    PubMed

    Küçükerdönmez, Cem; Karalezli, Aylin; Zengin, Mehmet Ozgur; Akova, Yonca Aydin

    2014-01-01

    To monitor the development of graft vascularization after pterygium excision with conjunctival autograft transplantation (CAT) using indocyanine green angiography (ICGA) and to compare the graft vascularization between 2 different fixation techniques (fibrin glue and sutures). A total of 26 eyes of 26 patients with primary pterygium were randomly assigned after pterygium excision as having either fibrin glue (13 eyes) or Vicryl sutures (13 eyes) for CAT. Anterior segment ICGA findings were evaluated postoperatively at 1, 7, and 15 days and the percentages of graft vascularization in both groups were compared using pixel analysis software program. The mean ± SD age of patients in the suture and fibrin glue groups was 52.1 ± 12.7 years and 57.1 ± 9.82 years, respectively. There was no statistically significant difference between the groups regarding age, sex, or follow-up (p<0.05 for all). Also, the mean intraoperative defect size was not significantly different between the groups, which was measured as 20.11 ± 10.44 mm2 in the suture group and 23.44 ± 12.34 mm2 in the fibrin glue group (p = 0.343). The mean percentage of vascularized graft area at postoperative day 1 and 7 was 18.1 ± 7.8% and 25.3 ± 8.6% in the suture group and 34.8 ± 10.2% and 66.1 ± 17.8% in the fibrin glue group. The difference between the groups was statistically significant (p<0.01 for both). At postoperative day 15, all grafts were 100% perfused in both groups. Fibrin glue fixation of conjunctival autografts led to more vascularization in the early postoperative period than suture fixated grafts, which in turn may have significance in terms of graft health and pterygium recurrence.

  16. Calibration of cathode strip gains in multiwire drift chambers of the GlueX experiment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Berdnikov, V. V.; Somov, S. V.; Pentchev, L.

    A technique for calibrating cathode strip gains in multiwire drift chambers of the GlueX experiment is described. The accuracy of the technique is estimated based on Monte Carlo generated data with known gain coefficients in the strip signal channels. One of the four detector sections has been calibrated using cosmic rays. Results of drift chamber calibration on the accelerator beam upon inclusion in the GlueX experimental setup are presented.

  17. Novel dural closure technique using polyglactin acid sheet prevents cerebrospinal fluid leakage after spinal surgery.

    PubMed

    Sugawara, Taku; Itoh, Yasunobu; Hirano, Yoshitaka; Higashiyama, Naoki; Shimada, Yoichi; Kinouchi, Hiroyuki; Mizoi, Kazuo

    2005-10-01

    Extradural or subcutaneous cerebrospinal fluid (CSF) leakage is a common complication after spinal surgery and is associated with the risks of poor wound healing, meningitis, and pseudomeningocele. Numerous methods to prevent postoperative CSF leakage are available, but pressure-tight dural closure remains difficult, especially with synthetic surgical membranes. The efficacy of a novel dural closure technique was assessed by detecting extradural or subcutaneous CSF leakage on magnetic resonance imaging. The novel dural closure technique using absorbable polyglactin acid sheet and fibrin glue and the conventional procedure using only fibrin glue were evaluated retrospectively by identifying extradural or subcutaneous CSF leakage on magnetic resonance imaging scans in the acute (2-7 d) and chronic (3-6 mo) postoperative stages after spinal intradural surgery in 53 patients. The incidence of extradural and subcutaneous CSF leakage was significantly lower (P < 0.05) in the acute (20%) and chronic (0%) stages using polyglactin acid sheet and fibrin glue in 15 patients compared with that in the acute (81%) and chronic (24%) stages using only fibrin glue in 38 patients. One patient in the fibrin glue-only group required repair surgery for cutaneous CSF leakage. The combination of polyglactin acid sheet and fibrin glue can achieve water-tight closure after spinal intradural surgery and can minimize the risk of intractable postoperative CSF leakage. This simple, economical technique is recommended for dural closure after spinal intradural surgery.

  18. Surgical and interventional radiographic treatment of dogs with hepatic arteriovenous fistulae.

    PubMed

    Chanoit, Guillaume; Kyles, Andrew E; Weisse, Chick; Hardie, Elizabeth M

    2007-04-01

    To report outcome after surgical and interventional radiographic treatment of hepatic arteriovenous fistulae (HAVF) in dogs. Retrospective study. Dogs (n=20) with HAVF. Medical records of dogs with HAVF were reviewed. Referring veterinarians and owners were contacted by telephone. History, clinical signs, biochemical and hematologic variables, ultrasonographic and angiographic findings, surgical findings, techniques used to correct the HAVF, survival time, and clinical follow-up were recorded. Canine HAVF often appeared to be an arteriovenous malformation rather than a single fistula. Multiple extrahepatic portosystemic shunts were identified in 19 dogs. Surgery (lobectomy or ligation of the nutrient artery) and/or interventional radiology (glue embolization of the abnormal arterial vessels) was performed in 17 dogs. Thirteen dogs were treated by surgery alone, 4 dogs by glue embolization alone, and 1 dog by glue embolization and surgery. Three dogs treated by surgery alone died <1 month later, and 3 dogs were subsequently euthanatized or died because of persistent clinical signs. None of the dogs treated by glue embolization died <1month after the procedure and all were alive, without clinical signs, at follow-up (9-17 months). Overall, 9 of 12 (75%) dogs with long-term follow-up required dietary or medical management of clinical signs. HAVF-related death occurred less frequently after glue embolization than after surgery. Glue embolization may be a good alternative to surgery for treatment of certain canine HAVF.

  19. Gluing for Raman lidar systems using the lamp mapping technique.

    PubMed

    Walker, Monique; Venable, Demetrius; Whiteman, David N

    2014-12-20

    In the context of combined analog and photon counting (PC) data acquisition in a Lidar system, glue coefficients are defined as constants used for converting an analog signal into a virtual PC signal. The coefficients are typically calculated using Lidar profile data taken under clear, nighttime conditions since, in the presence of clouds or high solar background, it is difficult to obtain accurate glue coefficients from Lidar backscattered data. Here we introduce a new method in which we use the lamp mapping technique (LMT) to determine glue coefficients in a manner that does not require atmospheric profiles to be acquired and permits accurate glue coefficients to be calculated when adequate Lidar profile data are not available. The LMT involves scanning a halogen lamp over the aperture of a Lidar receiver telescope such that the optical efficiency of the entire detection system is characterized. The studies shown here involve two Raman lidar systems; the first from Howard University and the second from NASA/Goddard Space Flight Center. The glue coefficients determined using the LMT and the Lidar backscattered method agreed within 1.2% for the water vapor channel and within 2.5% for the nitrogen channel for both Lidar systems. We believe this to be the first instance of the use of laboratory techniques for determining the glue coefficients for Lidar data analysis.

  20. Quantitative analysis of AgNOR proteins in buccal epithelial cells of Indian street boys addicted to gasp 'golden glue'.

    PubMed

    Mondal, Nandan Kumar; Ghosh, Sreenita; Ray, Manas Ranjan

    2011-11-01

    The effect of glue snuffle on the expression of argyrophilic nucleolar organizer regions (AgNORs), an indicator of ribosome biosynthesis, in epithelial cells of oral mucosa has been investigated. AgNOR was evaluated by cytochemical staining in 148 Indian street boys (median age 12 year) who had different bad addictions like tobacco smoking, chewing and most importantly inhaling glue and 20 age- and body mass index-matched school boys who had no such type of bad habit. Compared with school boys, glue addicted street boys showed remarkably increased number of AgNOR dots per nucleus (9.38±1.84 vs. 3.12±0.87, p<0.001), AgNOR size (1.34±0.52 vs. 0.43±0.02 μm(2), p<0.001) and percentage of AgNOR occupied nuclear area (9.38±2.12 vs. 0.99±0.03%, p<0.001). Increase in number and size of the dots is also higher in tobacco smokers and chewers when compared with school boys but a remarkable difference was recorded in glue addicted boys. The changes in AgNOR expression were positively associated with years of addiction after controlling potential confounders. Thus, glue snuffle appeared to be a risk factor for abnormal cell growth via up-regulation of ribosome biogenesis. Copyright © 2010 Elsevier GmbH. All rights reserved.

  1. Compression properties and dissolution of bioactive glass S53P4 and n-butyl-2 cyanoacrylate tissue adhesive-composite.

    PubMed

    Sarin, Jussi; Hiltunen, Markus; Hupa, Leena; Pulkkinen, Jaakko; Vallittu, Pekka K

    2016-09-28

    Bioactive glass (BG)-containing fiber-reinforced composite implants, typically screw-retained, have started to be used clinically. In this study, we tested the mechanical strength of composites formed by a potential implant adhesive of n-butyl-2-cyanoacrylate glue and BG S53P4 particles. Water immersion for 3, 10 or 30 days had no adverse effect on the compression strength. When cyanoacrylate glue-BG-composites were subjected to simulated body fluid immersion, the average pH rose to 7.52 (SD 0.066) from the original value of 7.35 after 7 days, and this pH increment was smaller compared to BG particle-group or fibrin glue-BG-composite group. Based on these results n-butyl-2 cyanoacrylate glue, by potentially producing a strong adhesion, might be considered a possible alternative for fixation of BG S53P4 containing composite implants. However, the mechanical and solubility properties of the cyanoacrylate glue may not encourage the use of this tissue adhesive with BG particles.

  2. Infrared Emissivity of Tin upon Release of a 25 GPa Shock into a LiF Window

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Turley, W. D., Holtkamp, D. B., Marshall, B. R., Stevens, G. D., Veeser, L. R.

    We measured the emissivity of a tin sample at its interface with a lithium-fluoride window upon release of a 25 GPa shock wave from the tin into the window. Measurements were made over four wavelength bands between 1.2 and 5.4 μm. Thermal emission backgrounds from the tin, glue, and lithium fluoride were successfully removed from the reflectance signals. Emissivity changes for the sample, which was initially nearly specular, were small except for the longest wavelength band, where uncertainties were high because of poor signal-to-noise ratio at that wavelength. A thin glue layer, which bonds the sample to the window, wasmore » found to heat from reverberations of the shock wave between the tin and the lithium fluoride. At approximately 3.4 μm the thermal emission from the glue was large compared to the tin, allowing a good estimate of the glue temperature from the thermal radiance. The glue appears to remain slightly colder than the tin, thereby minimizing heat conduction into or out of the tin immediately after the shock passage.« less

  3. Investigation of Layer Structure of the Takamatsuzuka Mural Paintings by Terahertz Imaging Technique

    NASA Astrophysics Data System (ADS)

    Inuzuka, M.; Kouzuma, Y.; Sugioka, N.; Fukunaga, K.; Tateishi, T.

    2017-04-01

    Terahertz imaging can be a powerful tool in conservation science for cultural heritages. In this study, a new terahertz imaging system was applied to the Takamatsuzuka mural painting of a blue dragon, and the condition of the plaster layer was diagnosed. As a result, the locations where the plaster layer appears solid on the surface but in actuality may have peeled off the underlying tuff stone were revealed and viewed as two-dimensional images.

  4. [A preliminary study on the forming quality of titanium alloy removable partial denture frameworks fabricated by selective laser melting].

    PubMed

    Liu, Y F; Yu, H; Wang, W N; Gao, B

    2017-06-09

    Objective: To evaluate the processing accuracy, internal quality and suitability of the titanium alloy frameworks of removable partial denture (RPD) fabricated by selective laser melting (SLM) technique, and to provide reference for clinical application. Methods: The plaster model of one clinical patient was used as the working model, and was scanned and reconstructed into a digital working model. A RPD framework was designed on it. Then, eight corresponding RPD frameworks were fabricated using SLM technique. Three-dimensional (3D) optical scanner was used to scan and obtain the 3D data of the frameworks and the data was compared with the original computer aided design (CAD) model to evaluate their processing precision. The traditional casting pure titanium frameworks was used as the control group, and the internal quality was analyzed by X-ray examination. Finally, the fitness of the frameworks was examined on the plaster model. Results: The overall average deviation of the titanium alloy RPD framework fabricated by SLM technology was (0.089±0.076) mm, the root mean square error was 0.103 mm. No visible pores, cracks and other internal defects was detected in the frameworks. The framework fits on the plaster model completely, and its tissue surface fitted on the plaster model well. There was no obvious movement. Conclusions: The titanium alloy RPD framework fabricated by SLM technology is of good quality.

  5. 29 CFR 530.101 - General.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... household glues available to the general public, but do not include potentially hazardous operations such as the use of industrial glues, epoxies, soldering irons, or heating elements. (b) This certificate may...

  6. 29 CFR 530.101 - General.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... household glues available to the general public, but do not include potentially hazardous operations such as the use of industrial glues, epoxies, soldering irons, or heating elements. (b) This certificate may...

  7. 29 CFR 530.101 - General.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... household glues available to the general public, but do not include potentially hazardous operations such as the use of industrial glues, epoxies, soldering irons, or heating elements. (b) This certificate may...

  8. 29 CFR 530.101 - General.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... household glues available to the general public, but do not include potentially hazardous operations such as the use of industrial glues, epoxies, soldering irons, or heating elements. (b) This certificate may...

  9. 29 CFR 530.101 - General.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... household glues available to the general public, but do not include potentially hazardous operations such as the use of industrial glues, epoxies, soldering irons, or heating elements. (b) This certificate may...

  10. Photoclickable dendritic molecular glue: noncovalent-to-covalent photochemical transformation of protein hybrids.

    PubMed

    Uchida, Noriyuki; Okuro, Kou; Niitani, Yamato; Ling, Xiao; Ariga, Takayuki; Tomishige, Michio; Aida, Takuzo

    2013-03-27

    A water-soluble dendron with a fluorescein isothiocyanate (FITC) fluorescent label and bearing nine pendant guanidinium ion (Gu(+))/benzophenone (BP) pairs at its periphery (Glue(BP)-FITC) serves as a "photoclickable molecular glue". By multivalent salt-bridge formation between Gu(+) ions and oxyanions, Glue(BP)-FITC temporarily adheres to a kinesin/microtubule hybrid. Upon subsequent exposure to UV light, this noncovalent binding is made permanent via a cross-linking reaction mediated by carbon radicals derived from the photoexcited BP units. This temporal-to-permanent transformation by light occurs quickly and efficiently in this preorganized state, allowing the movements of microtubules on a kinesin-coated glass plate to be photochemically controlled. A fundamental difference between such temporal and permanent bindings was visualized by the use of "optical tweezers".

  11. Proton mass decomposition

    NASA Astrophysics Data System (ADS)

    Yang, Yi-Bo; Chen, Ying; Draper, Terrence; Liang, Jian; Liu, Keh-Fei

    2018-03-01

    We report the results on the proton mass decomposition and also on the related quark and glue momentum fractions. The results are based on overlap valence fermions on four ensembles of Nf = 2 + 1 DWF configurations with three lattice spacings and volumes, and several pion masses including the physical pion mass. With 1-loop pertur-bative calculation and proper normalization of the glue operator, we find that the u, d, and s quark masses contribute 9(2)% to the proton mass. The quark energy and glue field energy contribute 31(5)% and 37(5)% respectively in the MS scheme at µ = 2 GeV. The trace anomaly gives the remaining 23(1)% contribution. The u, d, s and glue momentum fractions in the MS scheme are consistent with the global analysis at µ = 2 GeV.

  12. Dura covered with fibrin glue reduces adhesions in abdominal wall defects.

    PubMed

    Schier, F; Srour, N; Waldschmidt, J

    1991-12-01

    Dura can greatly facilitate the closure of abdominal wall defects. However, a main disadvantage of its use are the adhesions which develop between omentum, bowel and dura and may lead to bowel obstructions. In this study various groups of rats had either the anterior wall replaced by untreated dura or by dura covered with fibrin glue prior to implantation. Adhesions were found in 75% of sham operated rats, 100% after untreated dura implantation and 50% after the implantation of fibrin glue treated dura.

  13. A Novel, High-Resolution, High-Speed Fiber-Optic Temperature Sensor for Oceanographic Applications

    DTIC Science & Technology

    2015-05-11

    attached to the endface of a cleaved single-mode fiber using UV curable glue . A novel signal processing method has also been developed for the...thick Si wafer was bonded onto the tip of a single mode optical fiber using UV -curable glue . In addition to the sensor shown in Fig. 1(b), sensor...we developed a process to introduce much thicker silicon pieces onto the optical fiber tip. UV curable glue was first attached to the endface of

  14. DOE Office of Scientific and Technical Information (OSTI.GOV)

    B. R. Marshall

    Spectral reflectance was used to determine the thickness of thin glue layers in a study of the effect of the glue on radiance and reflectance measurements of shocked-tin substrates attached to lithium fluoride windows. Measurements based on profilometry of the components were found to be inaccurate due to flatness variations and deformation of the tin substrate under pressure during the gluing process. The accuracy of the spectral reflectance measurements were estimated to be ±0.5 μm, which was sufficient to demonstrate a convincing correlation between glue thickness and shock-generated light.

  15. Cyanoacrylate glue as an alternative mounting medium for resin-embedded semithin sections.

    PubMed

    Liu, Pei-Yun; Phillips, Gael E; Kempf, Margit; Cuttle, Leila; Kimble, Roy M; McMillan, James R

    2010-01-01

    Commercially available generic Superglue (cyanoacrylate glue) can be used as an alternative mounting medium for stained resin-embedded semithin sections. It is colourless and contains a volatile, quick-setting solvent that produces permanent mounts of semithin sections for immediate inspection under the light microscope. Here, we compare the use of cyanoacrylate glue for mounting semithin sections with classical dibutyl phthalate xylene (DPX) in terms of practical usefulness, effectiveness and the quality of the final microscopic image.

  16. Patient-performed pinnaplasty using industrial nail glue.

    PubMed

    Chadha, Priyanka; Bast, Florian

    2017-02-01

    Malformations of the pinna occur in around 2-5% of all newborns. Prominent ears in childhood can be a source of psychological distress and lead to bullying and social exclusion. We present the case of a 14-year-old girl who inflicted chronic, non-healing wounds in the post auricular area bilaterally after attempting to glue back her ears with industrial strength glue. To our knowledge, this is the first case of its kind to be published. Copyright © 2016. Published by Elsevier B.V.

  17. Development of high precision and cryogenic lens holders

    NASA Astrophysics Data System (ADS)

    Reutlinger, A.; Boesz, Anton; Mottaghibonab, A.; Eckert, P.; Dubowy, M.; Gebler, H.; Grupp, F.; Geis, N.; Bode, A.; Katterloher, R.; Bender, R.

    2017-11-01

    The optical system of the Near Infrared Spectrometer and Photometer (NISP) of the EUCLID mission consists mainly of a filter and grism wheel and 4 aspherical lenses with large diameters up to 170 mm. The single lenses require a high precision positioning at the operational temperature of 150 K. An additional design driver represents the CaF2 material of a lens, which is very sensitive wrt brittleness. The technical maturity of the combination of single features such as CaF2, large diameter (and mass), high precision and cryogenic conditions is considered as low. Therefore, a dedicated pre-development program has been launched to design and develop a first prototype of lens holder and to demonstrate the functional performance at representative operational conditions. The 4 lenses are divided into 3x lenses for the Camera Lens Assembly (CaLA) and 1x lens for the Corrector Lens Assembly (CoLA). Each lens is glue mounted onto solid state springs, part of an adaption ring. The adaption ring shall provide protection against vibration loads, high accuracy positioning, as well as quasi load free mounting of the lens under operational conditions. To reduce thermomechanical loads on the lens, the CTE of the adaption ring is adapted to that of the lens. The glue between lens and solid state spring has to withstand high tension loads during vibration. At the operational temperature the deviating CTE between glue and lens/adaption ring introduces shear loads into the glue interface, which are critical, in particular for the fragile CaF2 lens material. For the case of NISP the shear loads are controlled with the glue pad diameter and the glue thickness. In the context of the development activity many technology aspects such as various solid state spring designs, glue selection and glue handling have been investigated. A parametric structural model was developed to derive the specific design feature of each ring, such as spring force, number of springs, eigenfrequency, etc. This paper presents the design of the adaption ring in conjunction with test results from functional verification. These results are presented on behalf of the EUCLID consortium.

  18. Fibrin Glue Used as an Adhesive Agent in CNS Tissues

    PubMed Central

    Cheng, Henrich; Almström, Susanne; Olson, Lars

    1994-01-01

    One of the limitations of many bridging experiments in neural transplantation is that the CNS tissues cannot be sutured. Fibrin glue is a two-component system derived from whole blood which, when mixed, reproduces the final stage of blood coagulation and solidifies. Many experimental studies of humans and animals show that fibrin glue repair of peripheral nerves is almost equivalent to microsurgical sutures. In this study, we attempted to extend its use to CNS tissues and transplants. Two techniques were tried: (1) Bilateral parietal knife cuts were performed by stereotaxic technique in six rats. Fibrin glue was applied in the right-side cortical lesion. Immunohistochemistry using antisera to tyrosine hydroxylase (TH), glial fibrillary acidic protein (GFAP), laminin and neurofilament (NF) was essentially similar between the control and treatment groups. The immunoreactivity of each marker revealed no significant differences between the two groups on days 1, 7 and 30. There was no difference in terms of gliosis or microvascular proliferation. (2) Embryonic day 16 fetal locus coeruleus was grafted together with E16 cortex to the anterior chamber of sympathectomized eyes. In the six eyes of the glue treatment group, the parietal cortical piece and the locus coeruleus piece were joined together before grafting by immersing them in the solution of fibrin glue. In the eight eyes of the control group, pieces of parietal cortex and locus coeruleus were introduced individually and approximated by gently pressing the cornea. The sizes of double grafts showed no significant difference between groups during six weeks postgrafting. The immunohistochemical pictures using antisera against TH, GFAP and laminin were similar in both groups. Catecholaminergic fibers from the grafted locus coeruleus were found bridging over into the parietal cortical piece in both the control and treatment groups. There was no significant difference in TH-positive nerve fiber density between tissue glue joined and control double intraocular grafts. In conclusion, fibrin glue can be used as an adhesive agent in CNS tissues without hampering the outgrowth of neurites or causing adverse tissue reactions in fetal or adult nervous tissues. PMID:7578439

  19. Effect of a plaster containing DHEP and heparin in acute ankle sprains with oedema: a randomized, double-blind, placebo-controlled, clinical study.

    PubMed

    Coudreuse, J-M; de Vathaire, F

    2010-09-01

    Ankle sprains are the most frequent injuries in sport and daily life, and are usually treated with anti-inflammatory drugs or compounds that have an effect on microcirculation. The efficacy and tolerability of a novel plaster containing both diclofenac epolamine (DHEP) and heparin in the treatment of acute painful ankle sprains with oedema was investigated in a randomized, double-blind, placebo-controlled study. This study, carried out in 32 French medical centres, enrolled 233 patients (148 male and 86 female, aged 18-65 years) with an ankle sprain that had occurred within the previous 48 hours. Patients were treated once daily with DHEP heparin or placebo plaster for 7 days. Reduction in ankle joint swelling measured by submalleolar circumference was the primary efficacy endpoint; secondary endpoints were pain (at rest, in active mobilization, by passive stretch and by pressure), functional disability and global judgement of efficacy and tolerability. DHEP heparin-treated patients experienced a significantly greater reduction in joint swelling compared with placebo (p = 0.005). The reduction in pain was also in favour of DHEP heparin patients, with significantly lower pain in DHEP heparin-treated than placebo-treated patients within 3 hours of the first application (p < 0.05). Only two patients in the DHEP heparin plaster group and six in the placebo group experienced minor adverse events, all of which resolved spontaneously. By design, the study was limited to a placebo-controlled comparison, and there was no test for possible selection bias (subsequently ruled out by choice of efficacy parameters and measures) that may have resulted in a baseline imbalance between patient groups. Results confirm the efficacy of DHEP heparin plaster compared with placebo for the treatment of painful ankle sprain with oedema. Prompt control of pain and oedema may shorten the time to initiation of a rehabilitation programme, thus reducing the risk of ankle disability recurrence and the development of chronic injury.

  20. Use of polyurethane foam inside plaster casts to prevent the onset of heel sores in the population at risk. A controlled clinical study.

    PubMed

    Forni, Cristiana; Loro, Loretta; Tremosini, Morena; Mini, Sandra; Pignotti, Elettra; Bigoni, Ombretta; Guzzo, Giuseppe; Bellini, Laura; Trofa, Carmela; Di Cataldo, Anna M; Guzzi, Marilena

    2011-03-01

    The aim of this study was to test the effectiveness of polyurethane foam in contact with the heel inside a plaster cast to decrease the rate of pressure sores in the population at most risk. The rate of pressure sores caused by the plaster cast is reported to be 14-15% in the paediatric population, 33.3% in patients having undergone chemotherapy for bone tumours and 43% in orthopaedic patients who already have sore skin when the cast is applied (grade 1 lesion) to the heel. Controlled clinical trial. From November 2007-January 2009, all consecutive subjects requiring lower limb casts having undergone chemotherapy and/or presenting heel soreness received polyurethane foam in contact with the skin of the heel before applying the cast. The results were compared with those of patients with the same risk factors but were not administered the foam and were enrolled from May 2005-August 2006. In total, 156 patients were enrolled, 85 in the control group and 71 in the experimental group. In the experimental group, 2 of the 56 patients (3.6%) with sore skin developed a pressure sore compared with 21 of 49 (42.9%) in the control group without polyurethane foam (p < 0.0005). In the experimental group, one of the 24 patients (4.2%) patients undergoing chemotherapy developed a pressure sore compared with 18 of 54 (33.3%) in the control group (p = 0.005). Placing polyurethane foam in contact with the skin of the heel inside a plaster cast prevents the formation of pressure sores. This study provides evidence that using polyurethane foam to prevent sores even inside plaster casts in populations at most risk is a simple and cost-effective strategy and decreases the discomfort, pain and risks in these patients. © 2011 Blackwell Publishing Ltd.

  1. All Shook Up

    ERIC Educational Resources Information Center

    Barnes, Janet Bratton

    2011-01-01

    In this article, the author describes how second-grade students created animal rattles. For finishing touches, students can add faux fur, cords, beads, feathers, and other objects with glue or hot glue. (Contains 1 online resource.)

  2. Intensive Survey at 11-Jd-126, Jo Daviess County, Illinois. Volume 1.

    DTIC Science & Technology

    1983-07-01

    out. The joints between the roofing is also plastered; carefully covered about a foot thick with grass which we cut with our . knives, & four or...plaster had been pushed or smeared up against the walls or joints provide opportunities to reconstruct the diameter of the lath or withes in ,-any...of the sherds has one fairly complete edge and a small fracture on the opposing side from the opposite edge (see Figure 56), one can estimate an

  3. Dental Assistant, Advanced. Revision

    DTIC Science & Technology

    1989-02-01

    compound , or model- ing plaster instead of the rubber dam retainer Removing the Rubber Dam (figures 4-4 and 4-5). A ligature can also be used After the...roots or split crowns. If a is checked. When directed by the dental officer, ligature, dental compound , or modeling plaster remove the rubber dam...34clean" and 1 " dirty " JOB STEPS 1. Wash hands. 2. Recor! patient’s name. 3. Explain procedure to patient. 4. Tell patient to lie in bed or be seated

  4. Wastewater Sludge Used as Material for Bricks Fabrication

    NASA Astrophysics Data System (ADS)

    Jianu, N. R.; Moga, I. C.; Pricop, F.; Chivoiu, A.

    2018-06-01

    Current world trends related to wastewater sludges are: reuse in agriculture, utilization as retaining material for petroleum products or utilization in construction. Bricks from sand-cement or autoclaved cellular concrete are commonly used in construction. The authors propose innovative receipts for bricks and plasters based on textile wastewaters sludge. Centrifuged sludge is mixed with cement to obtain bricks and plaster. For bricks, the mixture is represented by 45% cement and 55% sludge. The paper presents the obtained results and the new materials used for bricks fabrication.

  5. FGD gypsum issues

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Buecker, B.

    2007-11-15

    The article first explains how gypsum by-product is produced in flue gas desulfurization systems in coal-fired power plants. It goes on to talk about the main markets for gypsum - wallboard manufacture (Plaster of Paris), cement production and soil stabilization. In the USA in 2006 41.6 million tons of gypsum was used by manufacturers of wallboard and plaster products, 3.0 mt for cement production and 1.1 mt for agricultural purposes. A method of determining the by-product gypsum content by thermogravimetric analysis is outlined. 4 refs., 1 fig.

  6. Recipes and Techniques for Producing Artist's Materials.

    ERIC Educational Resources Information Center

    School Arts, 1979

    1979-01-01

    Instructions are given for making oil ground, glue gesso, glue water size, oil colors, damar varnish, water colors, encaustic painting, egg tempera painting, etching inks, etching grounds, etching acids, and sugar-lift. (SJL)

  7. Lifetime Improvement of Organic Light Emitting Diodes using LiF Thin Film and UV Glue Encapsulation

    NASA Astrophysics Data System (ADS)

    Huang, Jian-Ji; Su, Yan-Kuin; Chang, Ming-Hua; Hsieh, Tsung-Eong; Huang, Bohr-Ran; Wang, Shun-Hsi; Chen, Wen-Ray; Tsai, Yu-Sheng; Hsieh, Huai-En; Liu, Mark O.; Juang, Fuh-Shyang

    2008-07-01

    This work demonstrates the use of lithium fluoride (LiF) as a passivation layer and a newly developed UV glue for encapsulation on the LiF passivation layer to enhance the stability of organic light-emitting devices (OLEDs). Devices with double protective layers showed a 25-fold increase in operational lifetime compared to those without any packaging layers. LiF has a low melting point and insulating characteristics and it can be adapted as both a protective layer and pre-encapsulation film. The newly developed UV glue has a fast curing time of only 6 s and can be directly spin-coated onto the surface of the LiF passivation layer. The LiF thin film plus spin-coated UV glue is a simple packaging method that reduces the fabrication costs of OLEDs.

  8. Fibre-Reinforced Adhesive for Structure Anchoring

    NASA Astrophysics Data System (ADS)

    Barnat, J.; Bajer, M.

    2015-11-01

    The topic of this paper is the glue-concrete interface of bonded anchors loaded by tension force. The paper is closely focused on bond strength experiments using high strength concrete up to class C50/60 or higher together with pure epoxy resin and fibre-reinforced resin. The goal of this research is to find the limits of the effective use of such glue types in high performance concrete, and also to verify the most commonly used design methods for bonded anchors. The presented research includes experimental analysis of the glue-concrete interface and the influence of its parameters on anchor behaviour. The presented analysis shows some problems of the 'separated failure modes' approach and also presents experimentally verified bond strength values obtained for the currently most widespread glue types. Results of fibre reinforced epoxy resin are also presented in this paper.

  9. Nail Damage (Severe Onychodystrophy) Induced by Acrylate Glue: Scanning Electron Microscopy and Energy Dispersive X-Ray Investigations

    PubMed Central

    Pinteala, Tudor; Chiriac, Anca Eduard; Rosca, Irina; Larese Filon, Francesca; Pinteala, Mariana; Chiriac, Anca; Podoleanu, Cristian; Stolnicu, Simona; Coros, Marius Florin; Coroaba, Adina

    2017-01-01

    Background Scanning electron microscopy (SEM) and energy dispersive X-ray (EDX) techniques have been used in various fields of medical research, including different pathologies of the nails; however, no studies have focused on obtaining high-resolution microscopic images and elemental analysis of disorders caused by synthetic nails and acrylic adhesives. Methods Damaged/injured fingernails caused by the use of acrylate glue and synthetic nails were investigated using SEM and EDX methods. Results SEM and EDX proved that synthetic nails, acrylic glue, and nails damaged by contact with acrylate glue have a different morphology and different composition compared to healthy human nails. Conclusions SEM and EDX analysis can give useful information about the aspects of topography (surface sample), morphology (shape and size), hardness or reflectivity, and the elemental composition of nails. PMID:28232921

  10. In vitro comparison of two widely used surgical sealants for treating alveolar air leak.

    PubMed

    Zhang, Ruoyu; Bures, Maximilian; Höffler, Klaus; Jonigk, Danny; Haverich, Axel; Krueger, Marcus

    2014-12-01

    Controversies surrounding the efficacy of sealants against alveolar air leak (AAL) are abundant in the literature. We sought to test the widely used sealants, TachoSil (Takeda Pharmaceutical Company Limited, Osaka, Japan) and BioGlue (CryoLife Europa Ltd., Surrey, United Kingdom) in an in vitro model. Materials and After creation of a focal superficial defect (40 × 25 mm) in swine lungs (n=40), AAL was assessed with increasing inspired tidal volume (TVi). Upon sealant application in a randomized order, AAL was assessed in the same way until sealant burst. At TVi =400, 500, 600, and 700 mL, BioGlue achieved sealing in 19, 19, 16, and 14 tests, while TachoSil sealed in 19, 14, 4, and no test, respectively. The maximally tolerated pressure of BioGlue was higher than TachoSil (40.3 ± 3.0 vs. 36.0 ± 4.9 cm H2O, p=0.003). Cohesive and adhesive failures were found in 10 and 1 tests of BioGlue, respectively, while all burst failures of TachoSil were adhesive. Concerning elasticity, TachoSil allowed more expansion of the covered defect than BioGlue (6.3 ± 3.9 vs. 1.4 ± 1.0 mm, p<0.001). The tested sealants demonstrated high sealing efficacy. While BioGlue was superior in resisting higher ventilation pressure, TachoSil possessed better elasticity. Georg Thieme Verlag KG Stuttgart · New York.

  11. Autologous Blood Versus Fibrin Glue in Pterygium Excision With Conjunctival Autograft Surgery.

    PubMed

    Nadarajah, Gaayathri; Ratnalingam, Vanitha Hema; Mohd Isa, Hazlita

    2017-04-01

    To evaluate graft stability and recurrence rate between fibrin glue and autologous blood in pterygium conjunctival autograft surgery. A prospective, randomized, single-blinded clinical trial to assess the efficacy of autologous blood in place of fibrin glue in pterygium surgery. A total of 120 eyes of 111 patients were randomized according to pterygium morphology, to undergo pterygium surgery with autografting using either autologous blood or fibrin glue. All patients were operated by a single surgeon; 58 eyes were operated using fibrin glue and 62 eyes had a conjunctival autograft with autologous blood. Patients were seen on postoperative day 1, 1 week, 1 month, 6 months, and 1 year after surgery. Graft stability and pterygium recurrence were graded by an independent observer who was masked to the method of treatment. All 120 eyes completed the 1-year follow-up. Graft loss was seen only in the autologous blood group. Of the 62 eyes in this group, a total of 15 (24.2%) grafts dislodged. Recurrence was calculated after excluding grafts that were dislodged. Of the 105 patients, there were a total of 7 recurrences, 2 (3.4%) from the fibrin adhesive method and 5 (10.6%) from the autologous blood method. This was not statistically significant (P = 0.238). Autologous blood does not exhibit similar graft stability seen with fibrin glue. Although the recurrence rate may not be significant, careful patient selection and a standard method needs to be laid out before the use of this method is widely accepted.

  12. Deep sea sedimentation processes and geomorphology: Northwest Atlantic continental margin

    NASA Astrophysics Data System (ADS)

    Mosher, David; Campbell, Calvin; Gardner, Jim; Chaytor, Jason; Piper, David; Rebesco, Michele

    2017-04-01

    Deep-sea sedimentation processes impart a fundamental control on the morphology of the western North Atlantic continental margin from Blake Spur to Hudson Strait. This fact is illustrated by the variable patterns of cross-margin gradients that are based on extensive new multibeam echo-sounder data informed by subbottom profiler and seismic reflection data. Erosion by off-shelf sediment transport in turbidity currents creates gullies, canyons and channels and a steep upper slope. Amalgamation of these conduits produces singular channels and turbidite fan complexes on the lower slope, flattening slope-profile gradients. The effect is an exponentially decaying "graded" slope profile. Comparatively, sediment mass failure produces steeper upper slopes due to head scarp development and a wedging architecture to the lower slope as deposits thin in the downslope direction. This process results in either a "stepped" slope, and/or a significant downslope gradient change where MTDs pinch out. Large drift deposits created by geostrophic currents are developed all along the margin. Blake Ridge, Sackville Spur, and Hamilton Spur are large detached drifts on disparate parts of the margin. They form a linear "above grade" profile along their crests from the shelf to abyssal plain. Deeper portions of the US continental margin are dominated by the Chesapeake Drift and Hatteras Outer Ridge; both plastered elongate mounded drifts. Farther north, particularly on the Grand Banks margin, are plastered and separated drifts. These drifts form "stepped" slope profiles, where they onlap the margin. Trough-mouth fan complexes become more common along the margin with increasing latitude. Sediment deposition and retention, particularly those dominated by glacigenic debris flows, characterize these segments producing an "above grade" slope profile. Understanding these geomorphological consequences of deep sea sedimentation processes is important to extended continental shelf mapping in which gradients and gradient change is a critical metric.

  13. Geometrical Tile Design for Complex Neighborhoods

    PubMed Central

    Czeizler, Eugen; Kari, Lila

    2009-01-01

    Recent research has showed that tile systems are one of the most suitable theoretical frameworks for the spatial study and modeling of self-assembly processes, such as the formation of DNA and protein oligomeric structures. A Wang tile is a unit square, with glues on its edges, attaching to other tiles and forming larger and larger structures. Although quite intuitive, the idea of glues placed on the edges of a tile is not always natural for simulating the interactions occurring in some real systems. For example, when considering protein self-assembly, the shape of a protein is the main determinant of its functions and its interactions with other proteins. Our goal is to use geometric tiles, i.e., square tiles with geometrical protrusions on their edges, for simulating tiled paths (zippers) with complex neighborhoods, by ribbons of geometric tiles with simple, local neighborhoods. This paper is a step toward solving the general case of an arbitrary neighborhood, by proposing geometric tile designs that solve the case of a “tall” von Neumann neighborhood, the case of the f-shaped neighborhood, and the case of a 3 × 5 “filled” rectangular neighborhood. The techniques can be combined and generalized to solve the problem in the case of any neighborhood, centered at the tile of reference, and included in a 3 × (2k + 1) rectangle. PMID:19956398

  14. Immunization by bovine thrombin used with fibrin glue during cardiovascular operations. Development of thrombin and factor V inhibitors.

    PubMed

    Berruyer, M; Amiral, J; Ffrench, P; Belleville, J; Bastien, O; Clerc, J; Kassir, A; Estanove, S; Dechavanne, M

    1993-05-01

    Brief case histories of three patients aged 58, 38, and 44 years are reported. All underwent cardiovascular operations. Subsequently hemostasis test abnormalities developed between the seventh and eighth postoperative days after exposure to bovine thrombin used with fibrin glue. These were characterized by an increased activated partial thromboplastin time (64 to 147 seconds), prothrombin time (19 to 24 seconds), bovine thrombin time (> 120 seconds) and a markedly reduced factor V level (< 10% in two patients and 16% in the third patient). A patient plasma dilution of 1 in 200 with a normal plasma pool was necessary to correct bovine thrombin time. No fast-acting or progressive inhibitor against factor V could be detected by coagulation tests, and fresh frozen plasma perfusion had no effect. Plasmapheresis was performed preventatively to avoid bleeding, and factor V levels stabilized at around 50% after two to four exchanges. Immunologic studies showed that the inhibitors were directed not only against bovine factors but also against human ones. Therefore factor V decrease could have been the result of rapid clearance from the circulation of complexes formed with a nonneutralizing inhibitor that is not detected by clotting tests. These antibodies were purified by standard methods and immunoaffinity. Fast immunization could be explained by a prior sensitization to bovine thrombin exposure during previous operations. It is suggested that bovine thrombin used with fibrin glue contains small amounts of factor V and may be responsible for these abnormalities. This is in agreement with previous literature reports. However, these described neutralizing factor V inhibitors, which were easily detected.

  15. Natural healing-inspired collagen-targeting surgical protein glue for accelerated scarless skin regeneration.

    PubMed

    Jeon, Eun Young; Choi, Bong-Hyuk; Jung, Dooyup; Hwang, Byeong Hee; Cha, Hyung Joon

    2017-07-01

    Skin scarring after deep dermal injuries is a major clinical problem due to the current therapies limited to established scars with poor understanding of healing mechanisms. From investigation of aberrations within the extracellular matrix involved in pathophysiologic scarring, it was revealed that one of the main factors responsible for impaired healing is abnormal collagen reorganization. Here, inspired by the fundamental roles of decorin, a collagen-targeting proteoglycan, in collagen remodeling, we created a scar-preventive collagen-targeting glue consisting of a newly designed collagen-binding mussel adhesive protein and a specific glycosaminoglycan. The collagen-targeting glue specifically bound to type I collagen in a dose-dependent manner and regulated the rate and the degree of fibrillogenesis. In a rat skin excisional model, the collagen-targeting glue successfully accelerated initial wound regeneration as defined by effective reepithelialization, neovascularization, and rapid collagen synthesis. Moreover, the improved dermal collagen architecture was demonstrated by uniform size of collagen fibrils, their regular packing, and a restoration of healthy tissue component. Collectively, our natural healing-inspired collagen-targeting glue may be a promising therapeutic option for improving the healing rate with high-quality and effective scar inhibition. Copyright © 2017 Elsevier Ltd. All rights reserved.

  16. Assessment of the adhesive properties of the bacterial polysaccharide FucoPol.

    PubMed

    Araújo, Diana; Alves, Vitor D; Campos, Joana; Coelhoso, Isabel; Sevrin, Chantal; Grandfils, Christian; Freitas, Filomena; Reis, Maria A M

    2016-11-01

    To address the industry's interest in finding novel biobased glues, the adhesive properties of the bacterial polysaccharide FucoPol were evaluated through shear bond strength tests. A FucoPol solution was used to bond different materials, namely, wood, glass, cardboard and cellulose acetate film. The shear strength was compared to that of the same adherends bonded with commercial synthetic glues. Wood-wood joints bonded with FucoPol formulation withstood 742.2±9.8kPa shear strength without detachment. FucoPol adhesive capacity for cardboard was comparable to that of the tested commercial glues (425±8.9kPa), yielding similar shear strength values (416.0±12.9kPa), while improved performance was shown for glass (115.1±26.2kPa) and cellulose acetate film (153.7±11.3kPa) comparing to the commercial glues (67.7-97.5kPa and 79.4-92.7kPa, respectively). This study demonstrates the adhesive properties of FucoPol, opening up the opportunity of using this bacterial polysaccharide for the development of new natural water-based glues, suitable to bond different materials. Copyright © 2016 Elsevier B.V. All rights reserved.

  17. Productivity improvement using industrial engineering tools

    NASA Astrophysics Data System (ADS)

    Salaam, H. A.; How, S. B.; Faisae, M. F.

    2012-09-01

    Minimizing the number of defects is important to any company since it influence their outputs and profits. The aim of this paper is to study the implementation of industrial engineering tools in a manufacturing recycle paper box company. This study starts with reading the standard operation procedures and analyzing the process flow to get the whole idea on how to manufacture paper box. At the same time, observations at the production line were made to identify problem occurs in the production line. By using check sheet, the defect data from each station were collected and have been analyzed using Pareto Chart. From the chart, it is found that glue workstation shows the highest number of defects. Based on observation at the glue workstation, the existing method used to glue the box was inappropriate because the operator used a lot of glue. Then, by using cause and effect diagram, the root cause of the problem was identified and solutions to overcome the problem were proposed. There are three suggestions proposed to overcome this problem. Cost reduction for each solution was calculated and the best solution is using three hair drier to dry the sticky glue which produce only 6.4 defects in an hour with cost of RM 0.0224.

  18. Salt attack in parking garage in block of flats

    NASA Astrophysics Data System (ADS)

    Beran, Pavel; Frankeová, Dita; Pavlík, Zbyšek

    2017-07-01

    In recent years many new block of flats with parking garages placed inside the buildings were constructed. This tendency brings beyond question benefits for residents and also for city planning, but it requires new design and structural approaches and advanced material and construction solutions. The analysis of plaster damage on partition wall in parking garage in one of these buildings is presented in the paper. The damage of studied plaster is caused by the salts which are transported together with snow on cars undercarriage into garage area during winter. The snow melts and water with dissolved salts is transported by the capillary suction from concrete floor into the rendered partition wall. Based on the interior temperature, adsorbed water with dissolved chlorides evaporates and from the over saturated pore solution are formed salt crystals that damages the surface plaster layers. This damage would not occur if the partition wall was correctly isolated from the floor finish layer in the parking garage.

  19. A novel approach for planning orthognathic surgery: the integration of dental casts into three-dimensional printed mandibular models.

    PubMed

    Ayoub, A F; Rehab, M; O'Neil, M; Khambay, B; Ju, X; Barbenel, J; Naudi, K

    2014-04-01

    A method of producing a composite model consisting of a three-dimensional printed mandible bearing plaster teeth is presented. Printed models were obtained from cone beam computed tomograms (CBCT) of dry human mandibles. The plaster casts of the teeth were obtained from impressions of the teeth of the dry mandibles. The distorted teeth of the printed models were removed and replaced by the plaster casts of the teeth using a simple transfer jig. The accuracy of the composite models obtained from six mandibles was assessed from laser scans. The scans of the dry mandibles and the composite models were superimposed and the magnitude of the discrepancies at six points on the dentition and six on the mandible were obtained. It was concluded that the errors of the method were small enough to be clinically significant. The use of the composite models is illustrated in two clinical cases. Copyright © 2013 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  20. CFD analysis of a rotary kiln using for plaster production and discussion of the effects of flue gas recirculation application

    NASA Astrophysics Data System (ADS)

    Gürtürk, Mert; Oztop, Hakan F.; Pambudi, Nugroho Agung

    2018-04-01

    In this study, the CFD analysis of the rotary kiln is carried out for examining effects of various parameters on energy consumption and efficiency of the rotary kiln. The flue gas recirculation using in many applications is a useful method for combusting of fuel unburned in the flue gas. Also, effects of flue gas recirculation on the combusting of fuel, operating temperature and efficiency of the rotary kiln are discussed in this study. The rotary kiln, which is considered in this study, is used in plaster plant. Two different CFD models were created and these models are compared according to many parameters such as temperature distribution, mixture fraction, the mass fraction of O2, CO, CO and CH4 in the combustion chamber. It is found that the plaster plant has a great potential for an increase in energy efficiency. Results obtained for producers of rotary kiln and burner will be useful for determining better design parameters.

  1. Accuracy of digital models generated by conventional impression/plaster-model methods and intraoral scanning.

    PubMed

    Tomita, Yuki; Uechi, Jun; Konno, Masahiro; Sasamoto, Saera; Iijima, Masahiro; Mizoguchi, Itaru

    2018-04-17

    We compared the accuracy of digital models generated by desktop-scanning of conventional impression/plaster models versus intraoral scanning. Eight ceramic spheres were attached to the buccal molar regions of dental epoxy models, and reference linear-distance measurement were determined using a contact-type coordinate measuring instrument. Alginate (AI group) and silicone (SI group) impressions were taken and converted into cast models using dental stone; the models were scanned using desktop scanner. As an alternative, intraoral scans were taken using an intraoral scanner, and digital models were generated from these scans (IOS group). Twelve linear-distance measurement combinations were calculated between different sphere-centers for all digital models. There were no significant differences among the three groups using total of six linear-distance measurements. When limited to five lineardistance measurement, the IOS group showed significantly higher accuracy compared to the AI and SI groups. Intraoral scans may be more accurate compared to scans of conventional impression/plaster models.

  2. Study on γ-ray exposure buildup factors and fast neutron-shielding properties of some building materials

    NASA Astrophysics Data System (ADS)

    Singh, Vishwanath P.; Badiger, N. M.; El-Khayatt, A. M.

    2014-06-01

    We have computed γ-ray exposure buildup factors (EBF) of some building materials; glass, marble, flyash, cement, limestone, brick, plaster of paris (POP) and gypsum for energy 0.015-15 MeV up to 40 mfp (mfp, mean free path) penetration depth. Also, the macroscopic effective removal cross-sections (ΣR) for fast neutron were calculated. We discussed the dependency of EBF values on photon energy, penetration depth and chemical elements. The half-value layer and kinetic energy per unit mass relative to air of building materials were calculated for assessment of shielding effectiveness. Shielding thicknesses for glass, marble, flyash, cement, limestone and gypsum plaster (or Plaster of Paris, POP) were found comparable with ordinary concrete. Among the studied materials limestone and POP showed superior shielding properties for γ-ray and neutron, respectively. Radiation safety inside houses, schools and primary health centers for sheltering and annual dose can be assessed by the determination of shielding parameters of common building materials.

  3. Traditional Glue, Adhesive and Poison Used for Composite Weapons by Ju/’hoan San in Nyae Nyae, Namibia. Implications for the Evolution of Hunting Equipment in Prehistory

    PubMed Central

    2015-01-01

    Ju/’hoan hunters from Nyae Nyae, near Tsumkwe in Namibia, demonstrate the manufacture of three fixative pastes made from plant extracts, and poison made from grubs and plant extracts. Ammocharis coranica and Terminalia sericea produce simple glue. Ozoroa schinzii latex mixed with carbonized Aristeda adscensionis grass is a compound adhesive. Composite poison is made from Chrysomelid grub viscera mixed with salivary extracts of Acacia mellifera inner bark and the tuber sap of Asparagus exuvialis. In order to document potential variability in the chaîne opératoire, and to eliminate inherent biases associated with unique observations, we studied manufacturing processes in three separate Nyae Nyae villages. Although there are methodological similarities in the Nyae Nyae area, we observed a few differences in contemporary traditions of poison manufacture. For example, some hunters make powder from Asparagus exuvialis tuber sap by boiling, reducing, hardening and grinding it, while others simply use heated sap. The Ju/’hoan hunting kit provides insights for archaeologists, but we must exercise caution when looking for continuity between prehistoric and historical technical systems. Some traditions have been lost to modern hunters, while others are new. We should also expect variability in the Stone Age because of geographically restricted resources. Simple glue, compound adhesive, and poison recipes identified in the Stone Age have no modern equivalents. By about 60,000 years ago at Diepkloof, simple glue was used for hafting tools, but at similarly-aged Sibudu there are recipes that combine red ochre powder with plant and/or animal ingredients. At Border Cave, novel poisons and compound adhesives were used in the Early Later Stone Age. It is possible that the complexity that we record in the manufacture of fixative pastes and poison used by Ju/’hoan hunters represents a hafting system both similar to and different from that observed at the Stone Age sites of Diepkloof, Sibudu, and Border Cave. PMID:26509730

  4. Optimized adhesives for strong, lightweight, damage-resistant, nanocomposite materials: new insights from natural materials

    NASA Astrophysics Data System (ADS)

    Hansma, P. K.; Turner, P. J.; Ruoff, R. S.

    2007-01-01

    From our investigations of natural composite materials such as abalone shell and bone we have learned the following. (1) Nature is frugal with resources: it uses just a few per cent glue, by weight, to glue together composite materials. (2) Nature does not avoid voids. (3) Nature makes optimized glues with sacrificial bonds and hidden length. We discuss how optimized adhesives combined with high specific stiffness/strength structures such as carbon nanotubes or graphene sheets could yield remarkably strong, lightweight, and damage-resistant materials.

  5. [Toxic polyneuropathy after sniffing contact glue thinner (author's transl)].

    PubMed

    Altenkirch, H; Mager, J

    1976-02-06

    Four men aged 16 to 19 years who had sniffed contact glue ("Pattex") thinner almost daily for 3 to 7 years developed a pronounced polyneuropathy. They had to be admitted nearly at the same time. A uniform neurological syndrome similar to Landry's paralysis with progressive ascending symmetrical pareses had developed. Motor deficiencies and atrophies affected the lower extremities more frequently and more severely. Only minimal sensory disturbances were found. The disease shows remarkable similarity to the "glue-sniffing neuropathy" described in the US and Japan which is attributed to n-hexane.

  6. Optimal Post-Operative Immobilisation for Supracondylar Humeral Fractures.

    PubMed

    Azzolin, Lucas; Angelliaume, Audrey; Harper, Luke; Lalioui, Abdelfettah; Delgove, Anaïs; Lefèvre, Yan

    2018-05-25

    Supracondylar humeral fractures (SCHFs) are very common in paediatric patients. In France, percutaneous fixation with two lateral-entry pins is widely used after successful closed reduction. Post-operative immobilisation is typically with a long arm cast combined with a tubular-bandage sling that immobilises the shoulder and holds the arm in adduction and internal rotation to prevent external rotation of the shoulder, which might cause secondary displacement. The objective of this study was to compare this standard immobilisation technique to a posterior plaster splint with a simple sling. Secondary displacement is not more common with a posterior plaster splint and sling than with a long arm cast. 100 patients with extension Gartland type III SCHFs managed by closed reduction and percutaneous fixation with two lateral-entry pins between December 2011 and December 2015 were assessed retrospectively. Post-operative immobilisation was with a posterior plaster splint and a simple sling worn for 4 weeks. Radiographs were obtained on days 1, 45, and 90. Secondary displacement occurred in 8% of patients. No patient required revision surgery. The secondary displacement rate was comparable to earlier reports. Of the 8 secondary displacements, 5 were ascribable to technical errors. The remaining 3 were not caused by rotation of the arm and would probably not have been prevented by using the tubular-bandage sling. A posterior plaster splint combined with a simple sling is a simple and effective immobilisation method for SCHFs provided internal fixation is technically optimal. IV, retrospective observational study. Copyright © 2018. Published by Elsevier Masson SAS.

  7. Objective assessment of plaster cast quality in pediatric distal forearm fractures: Is there an optimal index?

    PubMed

    Labronici, Pedro José; Ferreira, Leonardo Termis; Dos Santos Filho, Fernando Claudino; Pires, Robinson Esteves Santos; Gomes, Davi Coutinho Fonseca Fernandes; da Silva, Luiz Henrique Penteado; Gameiro, Vinicius Schott

    2017-02-01

    Several so-called casting indices are available for objective evaluation of plaster cast quality. The present study sought to investigate four of these indices (gap index, padding index, Canterbury index, and three-point index) as compared to a reference standard (cast index) for evaluation of plaster cast quality after closed reduction of pediatric displaced distal forearm fractures. Forty-three radiographs from patients with displaced distal forearm fractures requiring manipulation were reviewed. Accuracy, sensitivity, specificity, false-positive probability, false-negative probability, positive predictive value, negative predictive value, positive likelihood ratio, and negative likelihood ratio were calculated for each of the tested indices. Comparison among indices revealed diagnostic agreement in only 4.7% of cases. The strongest correlation with the cast index was found for the gap index, with a Spearman correlation coefficient of 0.94. The gap index also displayed the best agreement with the cast index, with both indices yielding the same result in 79.1% of assessments. When seeking to assess plaster cast quality, the cast index and gap index should be calculated; if both indices agree, a decision on quality can be made. If the cast and gap indices disagree, the padding index can be calculated as a tiebreaker, and the decision based on the most frequent of the three results. Calculation of the three-point index and Canterbury index appears unnecessary. Copyright © 2016 Elsevier Ltd. All rights reserved.

  8. Accuracy and precision of polyurethane dental arch models fabricated using a three-dimensional subtractive rapid prototyping method with an intraoral scanning technique.

    PubMed

    Kim, Jae-Hong; Kim, Ki-Baek; Kim, Woong-Chul; Kim, Ji-Hwan; Kim, Hae-Young

    2014-03-01

    This study aimed to evaluate the accuracy and precision of polyurethane (PUT) dental arch models fabricated using a three-dimensional (3D) subtractive rapid prototyping (RP) method with an intraoral scanning technique by comparing linear measurements obtained from PUT models and conventional plaster models. Ten plaster models were duplicated using a selected standard master model and conventional impression, and 10 PUT models were duplicated using the 3D subtractive RP technique with an oral scanner. Six linear measurements were evaluated in terms of x, y, and z-axes using a non-contact white light scanner. Accuracy was assessed using mean differences between two measurements, and precision was examined using four quantitative methods and the Bland-Altman graphical method. Repeatability was evaluated in terms of intra-examiner variability, and reproducibility was assessed in terms of inter-examiner and inter-method variability. The mean difference between plaster models and PUT models ranged from 0.07 mm to 0.33 mm. Relative measurement errors ranged from 2.2% to 7.6% and intraclass correlation coefficients ranged from 0.93 to 0.96, when comparing plaster models and PUT models. The Bland-Altman plot showed good agreement. The accuracy and precision of PUT dental models for evaluating the performance of oral scanner and subtractive RP technology was acceptable. Because of the recent improvements in block material and computerized numeric control milling machines, the subtractive RP method may be a good choice for dental arch models.

  9. [The advantages in using cyanoacrylate glue over skin staples as a method of skin graft fixation in the pediatric burns population].

    PubMed

    Curings, P; Vincent, P-L; Viard, R; Gir, P; Comparin, J-P; Voulliaume, D

    2017-11-23

    Local postoperative care and burn wound management can present with a certain degree of difficulty in the pediatric population. While the use of skin staples as a method of skin graft fixation is a well-known, rapid and simple method, their removal can be painful and may necessitate some sedation or even general anesthesia. We studied in this article the advantages and economic value of using the cyanoacrylate glue as a fixation method for skin grafts. A comparative study was carried out from 2012 to 2016. Hundred and eighteen infants with burns up to 5% of total body surface area were included in the study. Seventy-two infants had split thickness skin grafts fixed with skin staples. Forty-six infants had split thickness skin grafts fixed with cyanoacrylate glue. We compared the quality of graft, the sedation used during the first postoperative dressing, the length of hospital stay, the amount of glue used and the presence of complications. There is a difference between the two groups studied in terms of age and total burn surface area. The rate of graft take was 100% in both groups. The first postoperative dressing was carried out without the use of powerful analgesia in the cyanoacrylate group, while it was necessary to use general anesthesia in 64% of the skin staples group. The average length of stay in hospital after skin grafting was 4.9 days for the cyanoacrylate glue versus 6.5 days in the skin staples group. No complications were noted in the 2 groups. The use of cyanoacrylate glue allows rapid fixation of skin grafts and avoid general anesthesia for postoperative cares. Subsequently the length of hospital stay is reduced within 25%. The medico-economic value of glue protocol is highly significant compared to skin staples, while having similar good results and without significant problems. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  10. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mandapaka, A; Ghebremedhin, A; Patyal, B

    Purpose: Patients who undergo n-BCA glue embolization as part of treatment for AVMs are later referred for proton therapy. Knowing the relative stopping power of the glue accurately allows us to perform accurate dose calculations. In this study we experimentally determine the relative stopping power of an n-BCA mixture in a 126 MeV and 149.6 MeV proton beams. Methods: One unit of the TRUFILL™ n-BCA liquid embolic system consists of 1g unit of n-BCA, 1g unit of Tantalum powder and one 10mL vial of Ethiodized oil. The physician mixed 3:1 Ethiodized oil to n-BCA. Five units (20cc) of the n-BCAmore » liquid embolic glue were prepared and placed in a 6cm x 3cm x3cm Lucite container. The container was placed in front of a water tank in the proton beam path. A diamond detector (active volume 0.004mm3) was used to measure distal edge of depth dose of a modulated 126 MeV proton beam collimated using a 3cm brass aperture. The procedure was repeated with a container carrying the same amount of water placed in front of the water tank. The difference in the depth dose measured with glue and with water was used to determine the relative stopping power of the glue. The same determination was done earlier at 149.6 MeV using a different smaller sample (4cc) of n-BCA. Results: The relative stopping power of this particular n-BCA mixture was determined to be 1.06 at both 126 MeV and 149.6 MeV. We are working on obtaining the composition data of the n-BCA glue so we can perform Monte Carlo calculations. Conclusion: Accurate value of the stopping power of the n-BCA glue in the proton beam was determined to be 1.06. It will improve the accuracy of dose calculations in proton radiosurgery procedures on AVM patients with n-BCA embolization.« less

  11. Comparative study of safety and efficacy of synthetic surgical glue for mesh fixation in ventral rectopexy.

    PubMed

    Silveira, Raquel Kelner; Domingie, Sophie; Kirzin, Sylvain; de Melo Filho, Djalma Agripino; Portier, Guillaume

    2017-10-01

    Ventral mesh rectopexy (VMR) is a surgical option to treat rectal prolapse with pelvic floor dysfunction (PFD). Using synthetic surgical glue to fix the mesh to the anterior rectal wall after ventral dissection could be advantageous in comparison with sutured or stapled fixation. This study aimed to evaluate the safety and efficacy of synthetic surgical glue for mesh fixation compared with suture mesh fixation in VMR. This observational cohort study is a retrospective analysis conducted in a University Hospital Pelvic Surgery Center. All consecutive female patients (n = 176) who underwent laparoscopic or laparotomic VMR between January 2009 and December 2014 were included. Two groups were defined based on mesh fixation technique of the rectal wall: VMR with synthetic glue (n = 66) and VMR with suture (n = 110). The recurrence-free survival after VMR was determined by Kaplan-Meier method and multivariate analysis by Cox regression. Short-term postoperative complications, postoperative symptom improvement, the need for complementary treatment postoperatively, and procedure length were evaluated. A total of 176 females patients (mean age, 58.6 ± 13.7 years) underwent VMR with synthetic mesh. Mean recurrence-free survivals after VMR were 17.16 (CI 95% 16.54-17.80) and 17.33 (CI 95% 16.89-17.77) months in the glue group and the suture group, respectively (p > 0.05). Cox regression identified an independent effect on the recurrence risk of the external rectal prolapse, alone, or in combination with other anatomical abnormalities (HR = 0.37; CI 95% 0.14-0.93; p = 0.03). There was no significant difference of short-term postoperative morbidity, procedure length, postoperative symptom improvement, or need for complementary treatment postoperatively between suture versus glue groups (all p > 0.05). Use of glue to fix the mesh in VMR was safe and had no impact on outcomes. External prolapse was the unique significant predictive factor for recurrence.

  12. Percutaneous sclerotherapy of massive venous malformations of the face and neck using fibrin glue combined with OK-432 and pingyangmycin.

    PubMed

    Chen, Wei-liang; Huang, Zhi-quan; Zhang, Da-ming; Chai, Qiang

    2010-04-01

    Surgical excision is useful only for localized and limited lesions. The purpose of this study was to evaluate the clinical curative effect of percutaneous sclerotherapy of massive venous malformations of the face and neck using fibrin glue combined with OK-432 and pingyangmycin. Eighteen patients with massive venous malformations were treated with an injection of fibrin glue combined with OK-432 and pingyangmycin. All the patients had extreme swelling postoperatively with no major complications. The follow-up period ranged from 6 to 12 months. Twelve lesions were completely involuted, 4 lesions were mostly involuted, and 2 lesions were partially involuted. All of the patients had normal liver and kidney functions. None of the patients presented with hematologic toxic effects or signs of pulmonary involvement. Percutaneous sclerotherapy using fibrin glue combined with OK-432 and pingyangmycin provided a simple, safe, and reliable alternative treatment for massive venous malformations.

  13. Clinical experience with fibrin glue in cardiac surgery.

    PubMed

    Köveker, G; de Vivie, E R; Hellberg, K D

    1981-10-01

    Cardiac surgery is often associated with hemostatic abnormalities leading to severe bleeding. Special problems are to be expected, if prosthetic material has to be implanted. Preclotting of Dacron prostheses with blood is well established but failures are sometimes encountered. Several years ago a new hemostatic sealing system (fibrin glue) was introduced into therapy. Since 1978 fibrin glue has been applied in 176 patients. The indications were: 1. sealing of woven Dacron prostheses, 2. bleeding from suture-holes (Gore-Tex), 3. diffuse myocardial bleeding and 4. prevention of kinking of coronary artery grafts. In 32 patients with an aortoventriculoplasty operation using Dacron the "blood preclotting" and "fibrin sealing" methods were compared. In the fibrin glue group there was a significant reduction in postoperative blood loss as well as a shortening of the operation time (period of protamin administration to skin closure). No fibrinolytic dissolution of the fibrin layer on the prostheses was observed.

  14. Restoration of small bone defects at craniotomy using autologous bone dust and fibrin glue.

    PubMed

    Matsumoto, K; Kohmura, E; Kato, A; Hayakawa, T

    1998-10-01

    Bone gaps or burr holes often result in small but undesirable scalp or skin depressions after craniotomy. Whereas a number of reports have discussed cranioplasties to avoid large bone defects, little has been written about the problem of small bone defects which, despite their minor size, could result in bothersome cosmetic problems. This study was designed to assess a simple method to repair burr hole defects and bridge bone gaps with autologous bone dust and fibrin glue. Bone dust was collected when burr holes were created or craniectomy was performed. After replacement of the bone flap, the burr holes or bone gap were filled with a mixture of bone dust and fibrin glue. The mixture of bone dust and fibrin glue was easily shaped to fit bone defects, resulting in favorable cosmetic outcomes 1 to 5 years after operation.

  15. Using the DP-190 glue for adhesive attachment of a large space mirror and its rim

    NASA Astrophysics Data System (ADS)

    Vlasenko, Oleg; Zverev, Alexey; Sachkov, Mikhail

    2014-07-01

    The glue DP-190 is widely used for adhesive attachment of astrositall (zerodur) lightweight large-size space astronomical mirrors (diameter of 1.7 m and more) with elements of their frames of invar. Peculiarities of physicalmechanical behavior of the glue DP-190 when exposed to the environment during the ground operation and in orbit cause instability of the reflective surface quality of mirrors. In this report we show that even a small (around 1%-5%) volumetric deformation of a cylindrical adhesive layer with a thickness of 0.8 mm between the mirror and the rim element causes significant mirrors deformation. We propose to use adhesive layer of special form that allows to reduce volumetric deformations of the glue DP-190 up to three times. Here we present results based on primary mirror tests of the WSO-UV project.

  16. Deliberate self-harming application of superglue in the nose: case report and literature review.

    PubMed

    Tikka, T; Al Abduwani, J; Costello, D

    2015-01-01

    Accidental and non-accidental applications of superglue in the ear, nose and oral cavity have been reported previously. Surgical removal of glue from the nose is the current practice. This paper reports the case of an 18-year-old female, who presented with complete bilateral nasal occlusion due to deliberate self-application of superglue in both nostrils to avoid nasogastric tube insertion. Removal of glue was accomplished with a combination of local anaesthetic cream and acetone-soaked cotton buds, which caused only minimal discomfort to the patient. All traces of glue disappeared within 10 days, without causing damage to the nasal mucosa, nasal blockage or pain. To the best of our knowledge, this is the first case report of deliberate self-application of superglue in the nose. A successful non-surgical management option for the removal of glue from the nose is introduced.

  17. Fibrin glue versus sutures for conjunctival autografting in primary pterygium surgery.

    PubMed

    Romano, Vito; Cruciani, Mario; Conti, Luigi; Fontana, Luigi

    2016-12-02

    Pterygium, a growth of the conjunctiva over the cornea, is a progressive disease leading in advanced stages to visual impairment, restriction of ocular motility, chronic inflammation and cosmetic concerns. Surgical removal is the treatment of choice, but recurrence can be a problem. Currently the best surgical option in terms of recurrence is conjunctival autograft. To date the most common surgical methods of attaching conjunctival autografts to the sclera are through suturing or fibrin glue. Each method presents its own advantages and disadvantages. Sutures require considerable skill from the surgeon and can be associated with a prolonged operation time, postoperative discomfort and suture-related complications, whereas fibrin glue may give a decreased operation time, improve postoperative comfort and avoid suture-related problems. To assess the effectiveness of fibrin glue compared to sutures in conjunctival autografting for the surgical treatment of pterygium. We searched CENTRAL (which contains the Cochrane Eyes and Vision Trials Register) (2016, Issue 9), Ovid MEDLINE, Ovid MEDLINE In-Process and Other Non-Indexed Citations, Ovid MEDLINE Daily, Ovid OLDMEDLINE (January 1946 to October 2016), Embase (January 1980 to October 2016), the ISRCTN registry (www.isrctn.com/editAdvancedSearch), ClinicalTrials.gov (www.clinicaltrials.gov), and the World Health Organization (WHO) International Clinical Trials Registry Platform (ICTRP) (www.who.int/ictrp/search/en). We did not use any date or language restrictions in the electronic searches for trials. We last searched the electronic databases on 14 October 2016. We included randomised controlled trials (RCTs) in any setting where fibrin glue was compared with sutures to treat people with pterygium. Two review authors independently screened the search results, assessed trial quality, and extracted data using standard methodological procedures expected by Cochrane. Our primary outcome was recurrence of pterygium defined as any re-growth of tissue from the area of excision across the limbus onto the cornea. The secondary outcomes were surgical time and complication rate. We graded the certainty of the evidence using GRADE. We included 14 RCTs conducted in Brazil, China, Egypt, India, Malaysia, New Zealand, Philippines, Saudi Arabia, Sweden and Turkey. The trials were published between 2004 and 2016, and were assessed as a mixture of unclear and low risk of bias with three studies at high risk of attrition bias. Only adults were enrolled in these studies.Using fibrin glue for the conjunctival autograft may result in less recurrence of pterygium compared with using sutures (risk ratio (RR) 0.47, 95% CI 0.27 to 0.82, 762 eyes, 12 RCTs; low-certainty evidence). If pterygium recurs after approximately 10 in every 100 surgeries with sutures, then using fibrin glue may result in approximately 5 fewer cases of recurrence in every 100 surgeries (95% CI 2 fewer to 7 fewer cases). Using fibrin glue may lead to more complications compared with sutures (RR 1.92; 95% CI 1.22 to 3.02, 11 RCTs, 673 eyes, low-certainty evidence). The most common complications reported were: graft dehiscence, graft retraction and granuloma. On average using fibrin glue may mean that surgery is quicker compared with suturing (mean difference (MD) -17.01 minutes 95% CI -20.56 to -13.46), 9 RCTs, 614 eyes, low-certainty evidence). The meta-analyses, conducted on people with pterygium in a hospital or outpatient setting, show fibrin glue may result in less recurrence and may take less time than sutures for fixing the conjunctival graft in place during pterygium surgery. There was low-certainty evidence to suggest a higher proportion of complications in the fibrin glue group.

  18. Nutrient Deprivation Induces Property Variations in Spider Gluey Silk

    PubMed Central

    Blamires, Sean J.; Sahni, Vasav; Dhinojwala, Ali; Blackledge, Todd A.; Tso, I-Min

    2014-01-01

    Understanding the mechanisms facilitating property variability in biological adhesives may promote biomimetic innovations. Spider gluey silks such as the spiral threads in orb webs and the gumfoot threads in cobwebs, both of which comprise of an axial thread coated by glue, are biological adhesives that have variable physical and chemical properties. Studies show that the physical and chemical properties of orb web gluey threads change when spiders are deprived of food. It is, however, unknown whether gumfoot threads undergo similar property variations when under nutritional stress. Here we tested whether protein deprivation induces similar variations in spiral and gumfoot thread morphology and stickiness. We manipulated protein intake for the orb web spider Nephila clavipes and the cobweb spider Latrodectus hesperus and measured the diameter, glue droplet volume, number of droplets per mm, axial thread width, thread stickiness and adhesive energy of their gluey silks. We found that the gluey silks of both species were stickier when the spiders were deprived of protein than when the spiders were fed protein. In N. clavipes a concomitant increase in glue droplet volume was found. Load-extension curves showed that protein deprivation induced glue property variations independent of the axial thread extensions in both species. We predicted that changes in salt composition of the glues were primarily responsible for the changes in stickiness of the silks, although changes in axial thread properties might also contribute. We, additionally, showed that N. clavipes' glue changes color under protein deprivation, probably as a consequence of changes to its biochemical composition. PMID:24523902

  19. [Research progress on identification and quality evaluation of glues medicines].

    PubMed

    Li, Hui-Hu; Ren, Gang; Chen, Li-Min; Zhong, Guo-Yue

    2018-01-01

    Glues medicines is a special kind of traditional Chinese medicine.As the market demand is large, the raw materials are in short supply and lacks proper quality evaluation technology, which causes inconsistent quality of products on the market. Its authentic identification and evaluation stay a problem to be solved. In this paper, the research progress of the methods and techniques of the evaluation of the identification and quality of glues medicines were reviewed. The researches of medicinal glue type identification and quality evaluation mainly concentrated in four aspects of medicinal materials of physical and chemical properties, trace elements, organic chemicals and biological genetic methods and techniques. The methods of physicochemical properties include thermal analysis, gel electrophoresis, isoelectric focusing electrophoresis, infrared spectroscopy, gel exclusion chromatography, and circular dichroism. The methods including atomic absorption spectrometry, X-ray fluorescence spectrometry, plasma emission spectrometry and visible spectrophotometry were used for the study of the trace elements of glues medicines. The organic chemical composition was studied by methods of composition of amino acids, content detection, odor detection, lipid soluble component, organic acid detection. Methods based on the characteristics of biogenetics include DNA, polypeptide and amino acid sequence difference analysis. Overall, because of relative components similarity of the glues medicines (such as amino acids, proteins and peptides), its authenticity and quality evaluation index is difficult to judge objectively, all sorts of identification evaluation methods have different characteristics, but also their limitations. It indicates that further study should focus on identification of evaluation index and various technology integrated application combining with the characteristics of the production process. Copyright© by the Chinese Pharmaceutical Association.

  20. Cystoscopic injection of N-butyl-2-cyanoacrylate followed by fibrin glue for the treatment of persistent or massive vesicourethral anastomotic urine leak after radical prostatectomy.

    PubMed

    Lim, Ju Hyun; You, Dalsan; Jeong, In Gab; Park, Hyung Keun; Ahn, Hanjong; Kim, Choung-Soo

    2013-10-01

    Vesicourethral anastomotic urine leak is a common postoperative complication of radical prostatectomy. Herein we describe a novel method for the treatment of this complication. Intervention for a prolonged or massive anastomotic urine leak was required in 10 out of 1828 patients (0.5%) submitted to radical prostatectomy between 2007 and 2011. N-butyl-2-cyanoacrylate (Histoacryl) followed by fibrin glue (Greenplast) were injected under local anesthesia into vesicourethral anastomotic gaps under fluoroscopic guidance using a 20-Fr rigid cystoscope. Cystograms were taken in all patients to confirm complete urine leak resolution before the removal of the urethral catheter. Cystoscopic injection of Histoacryl followed by fibrin glue was technically successful and well tolerated in all patients. The mean time from radical prostatectomy to glue injection was 16.0 days (range 12-27 days). Urethral catheterization was required for an average of 7.7 days after cystoscopic injection of fibrin glue (range 3-13 days). These measures ultimately enabled complete resolution of the urine leak in all cases. At a mean follow up of 23.3 months, all 10 patients were fully continent. The mean time to recovery of urinary continence was 20.4 weeks (range 3.9-60.0 weeks). Cystoscopic injection of N-butyl-2-cyanoacrylate followed by fibrin glue into the anastomotic gap is both a feasible and effective solution in patients with a persistent or massive vesicourethral anastomotic urine leak after radical prostatectomy. © 2013 The Japanese Urological Association.

  1. Natura abhorret a vacuo--use of fibrin glue as a filler and sealant in neurosurgical "dead spaces". Technical note.

    PubMed

    Cappabianca, Paolo; Esposito, Felice; Magro, Francesco; Cavallo, Luigi Maria; Solari, Domenico; Stella, Lucio; de Divitiis, Oreste

    2010-05-01

    The objective of this study is to report our experience and illustrate our technique in the use of fibrin glue in the treatment of post-operatory cerebrospinal fluid (CSF) leaks and collections following different neurosurgical procedures. In a 3-year period, 40 subjects underwent endoscopic endonasal approach for different sellar and skull base lesions (three tuberculum sellae meningiomas, six craniopharyngiomas, three Rathke's cleft cysts and 28 pituitary macroadenomas), in which an intraoperative CSF leakage was evident. In such subjects, the fibrin glue was used as a first step of the final phase of the procedure-i.e. the reconstruction of the skull base defect-followed by the other materials employed. Furthermore, ten other patients, who had undergone transsphenoidal (four cases), spinal (two cases), posterior fossa (three cases) and transcortical intraventricular tumour removal (one case) neurosurgical procedures and developed CSF leaks or collections, were conservatively treated by single or repeated in situ injections of "modified" fibrin glue under local anaesthesia according to different described techniques. In total, 50 patients constitute the clinical material of the present study. In the cases where the fibrin glue was used during the reconstruction phase of the procedure (40 cases), the glue was injected inside the tumour cavity to fill the dead space left by the removal of the lesion. In case of post-operative CSF leak or CSF fluid collection (ten cases), after discarding 50-80% of the thrombin solution to obtain prevalence of the product's adhesive properties, fibrin glue was injected directly in the path of the CSF leak or into the collection cavity after aspiration of the collection's content. This was performed with the provided application system or through lumbar or Tuohy needles. Applications were repeated every 48 h until the disappearance of the leak. In all the treated cases, the disappearance of CSF leaks or collections was obtained with a number of applications ranging from one to five. Successful results are stable with a follow-up ranging from 6 months to 3 years. In our experience, the injection of fibrin glue has proved to be effective in filling or sealing post-operative "dead spaces" and treating minor or initial CSF leaks resulting from procedures of transsphenoidal, cranial and spinal surgery, adding another possibility in the management of many of these dreadful complications.

  2. DCT-TCI: Real Gas Characterization of Plasma Flow Control - An Integrated Approach

    DTIC Science & Technology

    2011-12-23

    as Navier-Stokes equations are solved in this study. We utilize the two-species basic model to reduce the computational complexity of plasma...constant of 3.0. Copper tape was first adhered to both sides of a 3 mm thick acrylic plate. A negative photo-resist, a transparent film and a UV light...ferric chloride. The reminiscence of the adhesive glue left behind by the copper tape was removed using a solvent such as methanol or acetone. The

  3. A different type of 'glue ear': report of an unusual case of prominent ears.

    PubMed

    Purcell, Elizabeth M; O'Neill, Ann C; Regan, Padraic J

    2003-09-01

    Prominent ears is a condition that can cause extreme psychological distress in young people. This cosmetic deformity can be corrected by otoplasty, an outpatient surgical procedure that is associated with a high rate of patient satisfaction. We report the unusual case of a teenage boy who had repeatedly applied cyanoacrylate adhesive ("superglue") to his postauricular skin in an attempt to pin back his prominent ears. This case of "glue ear" was ultimately resolved by successful otoplasty, although the residual effects of the glue resulted in delayed healing of the surgical wound.

  4. Successful closure of chronic BPF by thoracoscopy after failure of endoscopic fibrin glue application and thoracoplasty.

    PubMed

    Tschopp, J M; Evéquoz, D; Karrer, W; Aymon, E; Naef, A P

    1990-03-01

    We report a case of chronic debilitating BPF following right upper lobe resection. Despite several endobronchial applications of fibrin glue, we could not close it. Since the patient was extremely debilitated by symptoms due to the BPF, a thoracoplasty was attempted but was not successful. Finally, the BPF was definitely closed by instillation of talc into the pleura through thoracoscopy. To our knowledge, this is the first reported case of chemical closure of a recalcitrant BPF by the route of thoracoscopy. It also shows the failure of endoscopic fibrin glue application in such a condition.

  5. Study on the Optimal Groove Shape and Glue Material for Fiber Bragg Grating Measuring Bolts.

    PubMed

    Zhao, Yiming; Zhang, Nong; Si, Guangyao; Li, Xuehua

    2018-06-02

    Fiber Bragg grating (FBG) measuring bolts, as a useful tool to evaluate the behaviors of steel bolts in underground engineering, can be manufactured by gluing the FBG sensors inside the grooves, which are usually symmetrical cuts along the steel bolt rod. The selection of the cut shape and the glue types could perceivably affect the final supporting strength of the bolts. Unfortunately, the impact of cut shape and glue type on bolting strength is not yet clear. In this study, based on direct tension tests, full tensile load⁻displacement curves of rock bolts with different groove shapes were obtained and analyzed. The effects of groove shape on the bolt strength were discussed, and the stress redistribution in the cross-section of a rock bolt with different grooves was simulated using ANSYS. The results indicated that the trapezoidal groove is best for manufacturing the FBG bolt due to its low reduction of supporting strength. Four types of glues commonly used for the FBG sensors were assessed by conducting tensile tests on the mechanical testing and simulation system and the static and dynamic optical interrogators system. Using linear regression analysis, the relationship between the reflected wavelength of FBG sensors and tensile load was obtained. Practical recommendations for glue selection in engineering practice are also provided.

  6. PCM-enhanced lime plasters for vernacular and contemporary architecture

    NASA Astrophysics Data System (ADS)

    Theodoridou, Magdalini; Kyriakou, Loucas; Ioannou, Ioannis

    2016-04-01

    In 1997, the European Union (EU) pledged to reduce the amount of greenhouse gas emissions by 20% below the levels of 1990 by the end of 2020. In recent years it has become evident that, in order to reach that goal, EU Member States must take measures to encourage sustainability in the building industry, which is a major energy consumer. Such measures should involve the use of innovative, environmentally friendly materials and methods in new constructions, as well as the renovation of existing properties by upgrading their current state of energy efficiency. Phase Change Materials (PCMs) have the ability to absorb and release thermal energy, in the form of latent heat, during the melting or solidifying processes respectively. Thus, they may be used as additives in the production of thermally efficient composite building materials. A PCM-enhanced plaster is a heat storage medium combining an appropriate PCM with a cementitious or non-cementitious matrix to produce a low-cost thermal storage material with structural and thermostatic properties. Although innovative technologies, such as PCMs, have certainly contributed to the boost in the evolution of the building materials industry in recent years, a significant proportion of these technologies and practices have not yet been fully exploited in materials based on traditional principles. This paper focuses on the design and production of novel cementless PCM-enhanced lime plasters, in line with the traditional production technology of lime composites. The new plasters are produced using either hydrated or natural hydraulic lime binder, crushed calcarenite sand (0-2 mm) and commercial microencapsulated PCM in powder form (5% w/w of solids). Results from comparative tests between reference mixtures and mixtures with the addition of PCM, carried out 28, 56 and 90 days after laboratory production, prove the potential of PCMs in enhancing the thermal performance of traditional lime-based composites. The modified composites have significantly lower (by 55%) thermal conductivity and increased (by almost 20%) specific heat capacity at 90 days after laboratory production. At the same time, even though porosity values are higher for the PCM-enhanced renders, compared to the reference mixtures, their capillary absorption coefficient is significantly reduced (up to 60%). This is of great importance in the case of renders and may well be an indication for better expected durability in the long-term. Regarding the mechanical properties of the laboratory composites, PCM addition seems to have a negative effect on the hydraulic plasters. In contrast, when PCM is added to the hydrated lime-based plaster, no change is observed for the flexural strength, while the compressive strength is notably improved (up to 36%). The apparently improved properties of the PCM-enhanced plasters render them particularly appropriate for application in southern European climatic conditions. Due to their compatibility with traditional substrate materials (e.g. natural stone), the aforementioned composites may be used not only in new contemporary structures, but also for the renovation and retrofitting of existing buildings. The lime-based nature of their matrix and their physico-mechanical properties further extend their applicability to listed and monumental buildings.

  7. Glue versus suture for mesh fixation in inguinal hernia repair.

    PubMed

    Chandrasekar, Shruthi; Jeyakumar, S; Ganapathy, Tharun

    2018-03-22

    Inguinal hernia is one of the most common surgical problem presenting to the surgical OPD. Surgery is the mainstay of treatment for inguinal hernia today. Surgery for inguinal hernia has undergone a great evolution over a period of several centuries. Lichenstein's tension free hernioplasty is the one of the first surgeries taught to a surgical resident. The main aim of surgeries in this era is to give the best possible results with the least possible pain, scar and time. This has given rise to so many modifications to the classical Lichenstein's procedure and also to laparoscopic hernioplasty. Pain after inguinal hernia surgery is found to be debilitating and altering the quality of life in several patients, which has been attributed to the traumatic fixation of the mesh with sutures. This has paved way to the development of various atraumatic methods of fixation, tissue glue is one such development. Hence this study, to compare traumatic and atraumatic methods of mesh fixation in inguinal hernia repair. The aim of this study was to compare suture fixation versus tissue glue fixation of the mesh in inguinal hernia repair. Primary objective was to compare the immediate and chronic post-operative pain. Secondary objective was to compare the time taken for the procedure by the two methods in use and also to compare the presence of any complications. and methodology: This study was done in the General Surgery department of XXX hospital, medical college and research centre, kattangulathur after Ethics committee clearance. It is a single blinded study. The study was done on 51 patients consenting for the study and meeting the inclusion criterias from the period of March 2016 to August 2017 out of which 26 were selected for glue mesh fixation and 25 for suture mesh fixation according to simple randomization. The suture group patients underwent classical Lichenstein's tension free hernioplasty and the glue group underwent Lichenstein's hernioplasty with glue where dots of glue were used to fix the mesh instead of sutures. The tissue glue used in this study was N Butyl- 2 - Cyanoacrylate. All patients in the study underwent surgery only by one group of surgeons to maintain homogeneity and were observed in the hospital for 72 h. A note of the pain on VAS scale was made at 12, 24, 48, 72 h, 1 week, 1 month, 3 months and 6 months. Operative time and any complications were also recorded. Results developed using SPSS software show that there is a significant difference in the time taken by both the methods, with glue taking a significantly lower time than sutures. Significance is also seen in the difference in the immediate and chronic post-operative pain between both the groups. However the complication rates in both the groups were found to be the same. It can thus be concluded from this study that tissue glue mesh fixation is superior to suture mesh fixation in open inguinal repair in terms of operative time, immediate and chronic post-operative time. Copyright © 2018. Published by Elsevier Ltd.

  8. [Case-control study on effects of external fixation combined with limited internal fixation for the treatment of Pilon fractures of Rüedi-Allgower type III].

    PubMed

    Duan, Da-Peng; You, Wu-Lin; Ji, Le; Zhang, Yong-Tao; Dang, Xiao-Qian; Wang, Kun-Zheng

    2014-01-01

    To analyze the effects of three surgical operations in the treatment of Pilon fracture of Rüedi-Allgower type III, and put forward the best therapeutic method. The clinical data of 33 patients with Pilon fracture who received surgical operations (plaster immobilization group, 10 cases; distal tibia anatomical plate group, 11 cases; external fixation with limited internal fixation group, 12 cases) from October 2009 to January 2012 were analyzed. There were 5 males and 5 females, ranging in age from 24 to 61 years in the plaster immobilization group. There were 7 males and 4 females, ranging in age from 21 to 64 years in the distal tibia anatomical plate group. There were 7 males and 5 females, ranging in age from 23 to 67 years in the external fixation with limited internal fixation group. The Ankle X-ray of Pilon fracture after operation, ankle score, early and late complications were collected. Bourne system was used to evaluate ankle joint function. After 8 months to 3 years follow-up, it was found that three kinds of treatment had significant differences in the outcomes and complications (P < 0.05): the external fixation with limited internal fixation group got the best results. The number of anatomic reduction cases in the external fixation with limited internal fixation group (7 cases) and the distal tibia anatomical plate group (8 cases) was more than the plaster immobilization group (2 cases). According to the ankle score, 8 patients got an excellent result, 3 good and 1 poor in the limited internal fixation group ,which was better than those of distal tibia anatomical plate group (5 excellent, 4 good and 2 poor) and the plaster immobilization group (3 excellent, 4 good and 3 poor). The number of early and late complications in the external fixation with limited internal fixation group was more than those in the plaster immobilization group and the distal tibia anatomical plate group (P< 0.05). Treatment of external fixation with limited internal fixation in the treatment of Pilon fracture of Rüedi-Allgower type III is effective and safe.

  9. Safety and efficacy outcomes of long-term treatment up to 4 years with 5% lidocaine medicated plaster in patients with post-herpetic neuralgia.

    PubMed

    Sabatowski, Rainer; Hans, Guy; Tacken, Ingrid; Kapanadze, Sofia; Buchheister, Bettina; Baron, Ralf

    2012-08-01

    Prospective evaluation of the long-term efficacy and safety of the 5% lidocaine medicated plaster in patients with post-herpetic neuralgia (PHN). Patients with persisting pain for ≥3 months after acute herpes zoster and a baseline pain intensity of at least 4 on an 11-point numerical rating scale (NRS 0-10) were treated with 5% lidocaine medicated plasters for up to 5 years and monitored in regular intervals. Efficacy parameters are presented for the first 4 years and include patients' recall of pain relief (6-point verbal rating scale (VRS), clinical global impression of change (CGIC), patients' global impression of change PGIC), and the global evaluations of study medication. Safety parameters (clinical examination, skin evaluation, laboratory) and adverse events (AEs) were assessed at regular visits. KF10004/02. A total of 102 patients continuing from a 1 year main study period were included in an extension phase of up to 3 years. Ten patients (9.8%) dropped out due to lack of efficacy and 9 patients (8.8%) due to treatment-related AEs; 56 patients (54.9%) left the study for non-treatment-related reasons. Twenty-seven patients (26.4%) were still under treatment after a total treatment period of 4 years. On average, a pain relief of at least 4.3 (between moderate and a lot) was achieved throughout the study. At all visits the CGIC and the PGIC were much or very much improved in about 80% of patients. At the final visit, study medication was rated at least to be good by 91% of physicians and 89% of patients. Drug-related adverse events (DRAEs) were reported in 19 of 102 patients, mainly mild to moderate localized skin reactions. There were no hints for a reduced analgesic effect or an increase of DRAEs with long-term treatment. This study demonstrates that long-term treatment of ≥12 months with the 5% lidocaine medicated plaster is effective and well tolerated in PHN patients. These findings support the recommendations to use the 5% lidocaine medicated plaster as baseline therapy for localized neuropathic pain after herpes zoster infection (PHN).

  10. Vertical fixation with fibrin glue-assisted secondary posterior chamber intraocular lens implantation in a case of surgical aphakia

    PubMed Central

    Ladi, Jeevan S; Shah, Nitant A

    2013-01-01

    We report the first case of vertical fixation by fibrin glue-assisted secondary posterior chamber intraocular lens implantation in a case of surgical aphakia. Advantages of vertical fixation are discussed. PMID:23514650

  11. Accuracy and precision of polyurethane dental arch models fabricated using a three-dimensional subtractive rapid prototyping method with an intraoral scanning technique

    PubMed Central

    Kim, Jae-Hong; Kim, Ki-Baek; Kim, Woong-Chul; Kim, Ji-Hwan

    2014-01-01

    Objective This study aimed to evaluate the accuracy and precision of polyurethane (PUT) dental arch models fabricated using a three-dimensional (3D) subtractive rapid prototyping (RP) method with an intraoral scanning technique by comparing linear measurements obtained from PUT models and conventional plaster models. Methods Ten plaster models were duplicated using a selected standard master model and conventional impression, and 10 PUT models were duplicated using the 3D subtractive RP technique with an oral scanner. Six linear measurements were evaluated in terms of x, y, and z-axes using a non-contact white light scanner. Accuracy was assessed using mean differences between two measurements, and precision was examined using four quantitative methods and the Bland-Altman graphical method. Repeatability was evaluated in terms of intra-examiner variability, and reproducibility was assessed in terms of inter-examiner and inter-method variability. Results The mean difference between plaster models and PUT models ranged from 0.07 mm to 0.33 mm. Relative measurement errors ranged from 2.2% to 7.6% and intraclass correlation coefficients ranged from 0.93 to 0.96, when comparing plaster models and PUT models. The Bland-Altman plot showed good agreement. Conclusions The accuracy and precision of PUT dental models for evaluating the performance of oral scanner and subtractive RP technology was acceptable. Because of the recent improvements in block material and computerized numeric control milling machines, the subtractive RP method may be a good choice for dental arch models. PMID:24696823

  12. Reproducibility of the index of orthognathic functional treatment need scores derived from plaster study casts and their three-dimensional digital equivalents: a pilot study.

    PubMed

    McCrory, Emma; McGuinness, Niall Jp; Ulhaq, Aman

    2018-06-01

    To determine the reproducibility of Index of Orthognathic Functional Treatment Need (IOFTN) scores derived from plaster casts and their three-dimensional (3D) digital equivalents. Pilot study, prospective analytical. UK hospital orthodontic department. Thirty casts and their digital equivalents, representing the pre-treatment malocclusions of patients requiring orthodontic-orthognathic surgical treatment, were scored by four clinicians using IOFTN. Casts were scanned using a 3Shape digital scanner and 3D models produced using OrthoAnalyzer TM (3Shape Ltd, Copenhagen, Denmark). Examiners independently determined the IOFTN scores for the casts and digital models, to test their inter- and intra-operator reliability using weighted Kappa scores. Intra-operator agreement with IOFTN major categories (1-5: treatment need) was very good for plaster casts (0.83-0.98) and good-very good for digital models (0.78-0.83). Inter-operator agreement was moderate-very good for casts (0.58-0.82) and good-very good for digital models (0.65-0.92). Intra-operator agreement with IOFTN sub-categories (1-14: feature of malocclusion) was good-very good for casts (0.70-0.97) and digital models (0.80-0.94). Inter-operator agreement was moderate-good for casts (0.53-0.77); and moderate-very good for the digital models (0.58-0.90). Digital models are an acceptable alternative to plaster casts for examining the malocclusion of patients requiring combined orthodontic-orthognathic surgical treatment and determining treatment need.

  13. A new portable vibrator for plaster pouring: effect on the marginal fit at cylinder-abutment

    PubMed Central

    de ANDRADE, Pâmela Cândida Aires Ribas; LUTHI, Leonardo Flores; STANLEY, Kyle; CARDOSO, Antônio Carlos

    2012-01-01

    Objective The aim of this study was to test a new portable vibrator for plaster pouring (developed for this purpose), comparing the effect of its use on the accuracy of working cast of implant-supported restorations to the conventional vibrator. Material and methods From a master cast with 2 implants, 30 transfer moldings were made randomly and divided into three groups: Group I (GI): pouring performed in an outsourced dental laboratory with conventional plaster vibrator (10 casts), Group II (GII): pouring performed in the laboratory of the Federal University of Santa Catarina (UFSC) with conventional plaster vibrator (10 casts) and Group III (GIII): pouring performed with the portable vibrator fabricated for this study (10 casts). The position of the analogue and marginal adaptation of the infrastructure were verified by testing the single screw on the master model and on the working model. The measurement of misfit was blindly performed with a precision microscope and analyzing unit, Quadra-Check 200. The data were statistically analyzed by analysis of variance (ANOVA) and the Holm-Sidak test (α=0.05). Results Means±standard deviations were as follows: GI: 19.19±4.73 µm; GII: 21.72±5.41 µm; GIII: 13.5±2.39 µm (P<0.05), with GIII significantly lower as compared to the other groups. Conclusion Within the limitations of this study, it was concluded that a greater accuracy of working cast was achieved when a portable vibrator was used for casting molds. PMID:23138736

  14. Preliminary report of a sutureless onlay technique for incisional hernia repair using fibrin glue alone for mesh fixation.

    PubMed

    Stoikes, Nathaniel; Webb, David; Powell, Ben; Voeller, Guy

    2013-11-01

    The Rives repair for ventral/incisional (V/I) hernias involves sublay mesh placement requiring retrorectus dissection and transfascial stitches. Chevrel described a repair by onlaying mesh after a unique primary fascial closure. Although Chevrel fixated mesh to the anterior fascia with sutures, he used fibrin glue for fascial closure reinforcement. We describe an onlay technique with mesh fixated to the anterior fascia solely with fibrin glue without suture fixation. From January 2010 to January 2012, 50 patients underwent a V/I hernia onlay technique with fibrin glue mesh fixation. Records were reviewed for technical details, demographics, mesh characteristics, and postoperative outcomes. Primary fascial closure with interrupted permanent suture was done with or without myofascial advancement flaps. Onlay polypropylene mesh was placed providing 8 cm of overlap. Fibrin glue was applied over the prosthesis and subcutaneous drains were placed. Mean age was 62.4 years. Mean body mass index was 30.1 kg/m(2). Average mesh size was 14.5 cm × 19.1 cm. Mean operative time was 144.4 minutes (range, 38 to 316 minutes). Mean discharge was postoperative Day 2.9 (range, 0 to 15 days). Morbidity included eight seromas, one hematoma, and three wound infections. Seventeen patients required components separation. Mean follow-up was 19.5 months with no recurrences. This is the first series describing fibrin glue alone for mesh fixation for V/I hernia repair. It allows for immediate prosthesis fixation to the anterior fascia. Early results are promising. Potential advantages include less operative time, less technical difficulty, and less long-term pain. A prospective trial is needed to evaluate this approach.

  15. Effectiveness of glues for harmonic radar tag attachment on Halyomorpha halys (Hemiptera: Pentatomidae) and their impact on adult survivorship and mobility.

    PubMed

    Lee, Doo-Hyung; Wright, Starker E; Boiteau, Gilles; Vincent, Charles; Leskey, Tracy C

    2013-06-01

    We evaluated the effectiveness of three cyanoacrylate glues (trade names: Krazy [Elmer's Products Inc., Westerville, OH], Loctite [Henkel Corporation, Rocky Hill, CT], and FSA [Barnes Distribution, Cleveland, OH]) to attach harmonic radar tags securely on adult Halyomorpha halys (Stål) (Hemiptera: Pentatomidae) and quantified the effect of the radar tag attachment on insect survivorship and mobility. In the laboratory, the strength of the glue bond between the radar tag and H. halys pronotum was significantly increased when the pronotum was sanded to remove cuticular waxes. The adhesive bond of the radar tag to the sanded pronotum of H. halys had strength of 160-190-g force and there was no significant difference among the three types of glue tested. The three glues had no measurable effect on the survivorship of radar-tagged H. halys over 7 d, compared with untagged insects. Over a 7-d period in the laboratory, horizontal distance traveled, horizontal walking velocity, and vertical climbing distance were all unaffected by the presence of the tags regardless of glue. A field experiment was conducted to compare the free flight behavior of untagged and radar-tagged H. halys. Adults were released on a vertical dowel and their flights were tracked visually up to ≍200 m from the release point. There was no significant difference in take-off time or in flight distance, time, or speed between untagged and radar-tagged individuals. In addition, prevailing flight direction was not significantly different between untagged and radar-tagged individuals. The absence of measurable impact of the radar tag attachment on H. halys survivorship or mobility validates the use of harmonic radar tags to study the dispersal ecology of this insect in field conditions.

  16. Efficacy of a sheet combined with fibrin glue in repair of pleural defect at the early phase after lung surgery in a canine model.

    PubMed

    Sakai, Takashi; Matsutani, Noriyuki; Kanai, Eiichi; Yamauchi, Yoshikane; Uehara, Hirofumi; Iinuma, Hisae; Kawamura, Masafumi

    2018-02-01

    Polyglycolic acid and oxidized regenerated cellulose have been widely used as a sealant for repairing pulmonary air leakage during respiratory surgery. However, fundamental research of these materials has not been sufficiently conducted. Therefore, we conducted studies to assess the pressure resistance ability of these materials using a canine visceral pleural defect model at the early phase. The 6-mm circular defect and the 12-mm square defect were created on the visceral pleura of anesthetized beagles. These defects were then repaired using one of four methods: method A using polyglycolic acid and fibrin glue; method B using oxidized regenerated cellulose and fibrin glue; method C using oxidized regenerated cellulose; method D using fibrin glue. Airway pressure was measured as bursting pressure when air leakage from the repaired areas occurred at 5 min, 3 h, and 24 h after repair. For the 6-mm circle defect, method A showed higher bursting pressures than the other methods at 5 min and 3 h (p < 0.05); method B showed higher than methods C and D at 5 min and 3 h (p < 0.05). For the 12-mm square defect, method A showed higher bursting pressures than the other methods at all time points (p < 0.05). Moreover, method B showed higher than method C at 24 h (p < 0.05). Visceral pleural repairs using polyglycolic acid combined with fibrin glue showed the highest bursting pressure. Oxidized regenerated cellulose combined with fibrin glue showed sufficiently high bursting pressure in repair of small 6-mm circular defects.

  17. A biological tissue adhesive and dissolvent system for intraocular tumor plaque radiotherapy: an in vivo animal model experiment.

    PubMed

    Zloto, Ofira; Alezra, Dror; Sagiv, Oded; Belkin, Michael; Dai, Vicktoria Vishnevskia; Moroz, Iris; Greenberg, Gahl; Ben-Artsi, Elad; Fabian, Ido Didi

    2015-11-01

    To examine a novel biological adhesive and dissolvent system for plaque placement and removal using fibrin glue and urokinase, respectively, in an in vivo animal model. The study was performed on 23 rabbit eyes. Of these, eight underwent a technical feasibility study and ultrasonographic plaque displacement measurements, nine were examined clinically and by magnetic resonance imaging and histopathology for tissue reaction to the biological substances used, and in six the impact of fibrin glue as an orbital space occupier on intraocular pressure was assessed. In an additional ex vivo experiment, the glue's radiation attenuating properties were tested using an oncology EDR2 film. Plaque horizontal movement throughout follow-up (7-10 days) was negligible (0.5 ± 0.2 mm), and there was no tilting whatsoever. In the tissue response experiment, no adverse effects were recorded after application of fibrin or urokinase throughout the 21-day follow-up period. Interestingly, a circumscribed local inflammatory response was noted in tissue surrounding the fibrin glue, and persisted at 21 days. In the orbital space-occupying experiment, application of 1 cc fibrin glue did not cause a significant elevation in intraocular pressure (IOP) (P = 0.06), and in the ex vivo experiment, there was no significant difference between radiation readings with and without glue separation of the radioactive sources and film (P = 0.065). The adhesive and dissolvent system was feasible and safe for plaque placement and removal. It may be superior to conventional surgical plaque placement methods in eliminating the relatively common risk of plaque tilting and complications due to scleral suturing.

  18. Fibrin Tissue Sealant as an Adjunct to Cleft Palate Repair.

    PubMed

    Wu, Robin; Wilson, Alexander; Travieso, Roberto; Steinbacher, Derek M

    2017-07-01

    Fibrin glue is a common tissue sealant used to promote hemostasis, adhere tissues, and accelerate healing. Cleft palate repair can be technically challenging, creating dead space between tissue planes, and can be prone to complications such as would dehiscence or bleeding. The purpose of this study is to assess the role of fibrin glue as an adjunct to cleft palate repair. The authors hypothesize a beneficial impact on complication rates, including bleeding, dehiscence, and fistula formation, among others. Primary cleft palate repairs using fibrin glue were retrospectively analyzed. Demographic, intraoperative, perioperative, and postoperative data were combed for outcome variables. Complication rates were calculated in percentages and the results were compared to the published literature. Z-test statistics were performed for comparison. A total of 45 patients, 21 females and 24 males, who underwent primary cleft palate repair with fibrin glue between 2011 and 2014, had sufficient data to be reviewed. There were no instances of bleeding, dehiscence, airway obstruction, infection, oronasal fistula, or return to the operating room in any patients. One patient exhibited mild postoperative coughing and secretions that resolved with conservative measures. Another patient displayed postoperative seizure activity due to a pre-existing condition. All complication rates in our fibrin glue series were lower than those reported without the use of fibrin glue. Overall complication rates with fibrin sealant are significantly lower than overall complication rates without. Our data suggest that fibrin sealant is a beneficial adjunct to cleft palate repair. Its application is well-tolerated and the complication profile in our cohort was much less than the reported rates. The results of this preliminary study should be vetted with a prospective analysis involving a control group.

  19. Gluing the 'unwettable': soil-dwelling harvestmen use viscoelastic fluids for capturing springtails.

    PubMed

    Wolff, Jonas O; Schönhofer, Axel L; Schaber, Clemens F; Gorb, Stanislav N

    2014-10-01

    Gluing can be a highly efficient mechanism of prey capture, as it should require less complex sensory-muscular feedback. Whereas it is well known in insects, this mechanism is much less studied in arachnids, except spiders. Soil-dwelling harvestmen (Opiliones, Nemastomatidae) bear drumstick-like glandular hairs (clavate setae) at their pedipalps, which were previously hypothesized to be sticky and used in prey capture. However, clear evidence for this was lacking to date. Using high-speed videography, we found that the harvestman Mitostoma chrysomelas was able to capture fast-moving springtails (Collembola) just by a slight touch of the pedipalp. Adhesion of single clavate setae increased proportionally with pull-off velocity, from 1 μN at 1 μm s(-1) up to 7 μN at 1 mm s(-1), which corresponds to the typical weight of springtails. Stretched glue droplets exhibited characteristics of a viscoelastic fluid forming beads-on-a-string morphology over time, similar to spider capture threads and the sticky tentacles of carnivorous plants. These analogies indicate that viscoelasticity is a highly efficient mechanism for prey capture, as it holds stronger the faster the struggling prey moves. Cryo-scanning electron microscopy of snap-frozen harvestmen with glued springtails revealed that the gluey secretions have a high affinity to wet the microstructured cuticle of collembolans, which was previously reported to be barely wettable for both polar and non-polar liquids. Glue droplets can be contaminated with the detached scaly setae of collembolans, which may represent a counter-adaptation against entrapment by the glue, similar to the scaly surfaces of Lepidoptera and Trichoptera (Insecta) facilitating escape from spider webs. © 2014. Published by The Company of Biologists Ltd.

  20. Durability of traditional plasters with respect to blast furnace slag-based plaster

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cerulli, T.; Pistolesi, C.; Maltese, C.

    2003-09-01

    Blast furnace slag is a residue of steel production. It is a latent hydraulic binder and is normally used to improve the durability of concrete and mortars. Slag could be also used as rendering mortar for masonry and old buildings. Today, cement and hydraulic lime are the most popular hydraulic binders used to make plasters. They are characterised by a low durability when exposed to the action of chemical and physical agents. The aim of this study was to provide a comparison between the physical-mechanical properties of some renders made with ordinary Portland cement, hydraulic lime, or slag. Furthermore, anmore » investigation was carried out to analyse mortar resistance to several aggressive conditions like acid attack, freezing and thawing cycles, abrasion, sulphate aggression, cycles in ultraviolet screening device, and salt diffusion. The specimens, after chemical attack, have been characterised from the chemical-physical [specific surface according to the BET (Brunauer-Emmet-Teller) method], crystal-chemical (X-ray diffraction, XRD), and morphological (scanning electron microscopy, SEM) points of view.« less

  1. Severed cuff inflation tubing of endotracheal tube: A novel way to prevent cuff deflation.

    PubMed

    Rao, Amrut K; Chaudhuri, Souvik; Joseph, Tim T; Kamble, Deependra; Gotur, Gopal; Venkatesh, Sandeep

    2014-01-01

    A well-secured endotracheal tube (ETT) is essential for safe anesthesia. The ETT has to be fixed with the adhesive plasters or with tie along with adhesive plasters appropriately. It is specially required in patients having beard, in intensive care unit (ICU) patients or in oral surgeries. If re-adjustment of the ETT is necessary, we should be cautious while removal of the plasters and tie, as there may be damage to the cuff inflation system. This can be a rare cause of ETT cuff leak, thus making maintenance of adequate ventilation difficult and requiring re-intubation. In a difficult airway scenario, it can be extremely challenging to re-intubate again. We report an incidence where the ETT cuff tubing was severed while attempting to re-adjust and re-fix the ETT and the patient required re-intubation. Retrospectively, we thought of and describe a safe, reliable and novel technique to prevent cuff deflation of the severed inflation tube. The technique can also be used to monitor cuff pressure in such scenarios.

  2. Silesia Dryvit

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Presz, K.

    1995-12-31

    MT International, as a manufacturer and distributor for of US company named Dryvit Systems is focused on weatherization techniques as well as on facade and external wall finishing. The materials manufactured by Dryvit for building and construction purposes (plaster masses, building binders, insulating materials, reinforced fabric, etc.) are used at many sites. The consistent and well-selected composition of these materials guarantees highest quality of facade finishing in building structures of any type. The first implementation of Dryvit system in Warsaw was completed in 1974 and it remains the first exampled of professionally weatherized building in Poland. Different versions of Dryvitmore » system have been elaborated for various plaster base types. Consequently the assembling procedure differs, too. The main classification includes methods used directly on-site by a specialized contractor as well as prefabrication systems in which the ready-made elements prefabricated in a central plant or in a moveable unit are mounted on the walls. Distribution of materials and systems is based upon a network of branch offices and plaster mass mixter plants located in Warsaw, Szczecin, Lublin, Gdansk and Zabrze.« less

  3. Tissue glue in sutureless vitreoretinal surgery for the treatment of wound leakage.

    PubMed

    Batman, Cosar; Ozdamar, Yasemin; Aslan, Ozlem; Sonmez, Kenan; Mutevelli, Seda; Zilelioglu, Guler

    2008-01-01

    To assess the surgical outcomes of the use of tissue glue to close sclerotomy sites when required and the views of ultrasound biomicroscopy of the sclerotomy sites in 23- and 25-gauge vitrectomy systems. A 25-gauge transconjunctival sutureless vitrectomy was performed in 38 eyes and a 23-gauge transconjunctival sutureless vitrectomy was performed in 46 eyes for various vitreoretinal diseases. Wound leakage occurred at the sclerotomy sites at the end of the surgery in 6 eyes with 23-gauge transconjunctival sutureless vitrectomy and 7 eyes with 25-gauge transconjunctival sutureless vitrectomy. The sclerotomy sites were closed by using tissue glue to prevent wound leakage and evaluated with ultrasound biomicroscopy postoperatively. No wound leakage was observed at the end of the surgical procedure or during the follow-up period. Abnormal fibrous ingrowth was not detected at the sclerotomy sites by means of ultrasound biomicroscopy. The results demonstrated the efficacy of tissue glue for closing site ports when wound leakage is observed in transconjunctival sutureless vitreoretinal surgery.

  4. [The influence of biological compatibility of the cyanoacrylate glue on regeneration of the cartilaginous tissue].

    PubMed

    Semenov, F V; Skibitskaya, N F

    The objective of the present study was to evaluate the possibility of the application of the cyanoacrylate-based glue for the strengthening of the reconstructed elements of the middle ear and its influence on the regeneration of the cartilaginous tissue. We used the cartilaginous tissue from the auricles of the male California rabbits as a model. The cartilage was destroyed in a standard press. Half of the cartilage thus fragmented was implanted into the left auricle. The remaining part was mixed up with the cyanoacrylate glue and implanted into the right auricle of the same animal. The implanted material was used for the morphological study on day 10, within 1 and 2 months after the beginning of the experiment. The results of the study confirm the absence of the toxic action of the biologically compatible cyanoacrylate-based glue on the regeneration of the cartilaginous and connective tissues which suggests the possibility of its application for the surgical treatment of the diseases of the middle ear.

  5. Fibrin glue as interposition graft for tarsal coalition.

    PubMed

    Weatherall, Justin M; Price, Andrew E

    2013-01-01

    We describe a surgical technique and report outcomes for fibrin glue interposition after resection of a tarsal condition. An institutional review board--approved retrospective review of all pediatric patients with a tarsal coalition managed with resection was conducted between January 2002 and July 2010 by a single surgeon. All coalitions were resected with interposition of fibrin glue. Patients were evaluated for postoperative complications, pain, weight-bearing status, return to sports, and ankle and subtalar range of motion. Six feet without a coalition were used as a control group. Nine patients (12 feet) were identified with mean follow-up of 2.1 years (range, 7-72 months). Pre-operative complaints were predominantly foot and ankle pain. Patients also reported flatfeet and recurrent ankle sprains. There were no reported postoperative complications. All 9 patients were weight-bearing as tolerated and returned to sports by 6 months. Fibrin glue is a safe and reliable alternative to tissue grafts for interposition after resection of a tarsal coalition.

  6. Does fibrin glue reduce lymph leakage (pleural effusion) after extended esophagectomy? Prospective randomized clinical trial.

    PubMed

    Tachibana, Mitsuo; Kinugasa, Shoichi; Yoshimura, Hiroshi; Dhar, Dipok Kumar; Ueda, Shuhei; Fujii, Toshiyuki; Kohno, Hitoshi; Nagasue, Naofumi

    2003-07-01

    Fibrin glue has been shown to be effective in improving postoperative chylothorax following various thoracic procedures and in reducing lymphorrhea after axillary dissection. It is unknown, however, whether fibrin glue is effective in reducing lymph leakage (pleural effusion) after esophagectomy. A series of 43 consecutive patients with thoracic esophageal cancer who underwent extended esophagectomy were prospectively randomized to two groups: group A (n = 21), in whom 3 ml of fibrin glue was applied to the dissected mediastinum; and group B (n = 22), in whom fibrin glue was not applied. The time of drain removal and the volume of the thoracic drainage were compared. All data were expressed as the mean +/- standard deviation. There were no significant differences in the clinicopathologic characteristics between the two groups. None of the patients developed chylothorax or died during their hospital stay. The daily volume from the thoracic drain (457 +/- 273 ml) was significantly (p < 0.05) larger on postoperative day (POD) 1 in group A than in group B (298 +/- 158 ml) and tended to be larger (p < 0.10) on PODs 4 and 6 in group A than in group B. The cumulative drainage volume was significantly (p < 0.05) larger on PODs 4 to 6 and POD 9, and it tended to be larger (p < 0.10) on PODs 1, 3, 7, 8, 10, and 11 in group A than in group B, suggesting that the cumulative drainage volume in group A was consistently larger than that in group B. The cumulative numbers of patients with a drain remaining in place were not significantly different for the two groups (p = 0.4683). Three patients in group A, however, had prolonged insertion (> 20 days) of the chest tube. There were no significant differences in the incidence of postoperative chest-related complications. No patients in group A developed viral infectious disease during the long-term follow-up. Application of fibrin glue to the dissected mediastinum seems to induce postoperative lymph leakage and thus be responsible for prolonged chest tube insertion in some patients. Hence the use of fibrin glue cannot be recommended for reducing lymph leakage after esophagectomy.

  7. Experimental closure of gunshot wounds by fibrin glue with antibiotics in pigs.

    PubMed

    Djenić, Nebojša; Višnjić, Milan; Dragović, Saša; Bojanić, Vladmila; Bojanić, Zoran; Djurdjević, Dragan; Djindjić, Boris; Kostov, Miloš

    2015-09-01

    Gunshot wounds caused by the automatic rifle M70AB2 (AK-47) 7.62 mm, after the primary surgical management, were closed with delayed primary suture during the next four to seven days. This period coincides with the fibroblastic phase of wound healing. Fibrin glue is used as a local hemostatic and as a matrix for the local dosed release of antibiotics. Antibiotics addition to fibrin glue resulted in continuous diffusion into the surrounding next 4 to 7 days. The aim of this study was to create the preconditions for gunshot wounds closing without complications by the application of fibrin glue with antibiotics 24 h after primary surgical treatment. A total of 14 pigs were wounded in the gluteofemoral region by the bullet M67, initial velocity of 720 m/s. All wounded animals were surgically treated according to the principles of the war-surgery doctrine. Seven wounds were closed with primary delayed suture four days after the primary surgical treatment (traditional approach). Fibrin glue with antibiotics was introduced in seven wounds during the primary surgical treatment and primary delayed suture was done after 24 h. The macroscopic appearance and the clinical assessment of the wound were done during the primary surgical treatment and during its revision after 24 h, as well as histopathological findings at the days 4 and 7 after wounding. Gunshot wounds caused by the automatic rifle M70AB2 (AK-47) 7.62 mm, and treated with fibrin glue with antibiotics after primary surgical management, were closed with primary delayed suture after 24 h. In further wound evolution there were no complications. Uncomplicated soft-tissue wounds caused by an automatic M70AB2 rifle may be closed primarily with delayed suture without the risk of developing complications if on revision, 24 h after primary surgery, there were no present necrotic tissues, hematoma, and any signs of infection when fibrin glue with antibiotics (ceftriaxone and clindamycin) was applied. The use of this method should be limited to individual and strictly controlled cases in civil practice for now.

  8. GLUE 2 deployment: Ensuring quality in the EGI/WLCG information system

    NASA Astrophysics Data System (ADS)

    Burke, Stephen; Alandes Pradillo, Maria; Field, Laurence; Keeble, Oliver

    2014-06-01

    The GLUE 2 information model is now fully supported in the production EGI/WLCG information system. However, to make it usable and allow clients to rely on the published information it is important that the meaning is clearly defined, and that information providers and site configurations are validated to ensure as far as possible that what they publish is correct. In this paper we describe the definition of a detailed schema usage profile, the implementation of a software tool to validate published information according to the profile and the use of the tool in the production Grid, and also summarise the overall state of GLUE 2 deployment.

  9. LINC Complexes Form by Binding of Three KASH Peptides to Domain Interfaces of Trimeric SUN Proteins

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sosa, Brian A.; Rothballer, Andrea; Kutay, Ulrike

    Linker of nucleoskeleton and cytoskeleton (LINC) complexes span the nuclear envelope and are composed of KASH and SUN proteins residing in the outer and inner nuclear membrane, respectively. LINC formation relies on direct binding of KASH and SUN in the perinuclear space. Thereby, molecular tethers are formed that can transmit forces for chromosome movements, nuclear migration, and anchorage. We present crystal structures of the human SUN2-KASH1/2 complex, the core of the LINC complex. The SUN2 domain is rigidly attached to a trimeric coiled coil that prepositions it to bind three KASH peptides. The peptides bind in three deep and expansivemore » grooves formed between adjacent SUN domains, effectively acting as molecular glue. In addition, a disulfide between conserved cysteines on SUN and KASH covalently links both proteins. The structure provides the basis of LINC complex formation and suggests a model for how LINC complexes might arrange into higher-order clusters to enhance force-coupling.« less

  10. Glue-Sniffing: A Comparison Study of Sniffers and Non-Sniffers.

    ERIC Educational Resources Information Center

    Jansen, P.; And Others

    1992-01-01

    Compared 22 glue sniffers and 22 nonsniffers from group of street children and adolescents living in supervised shelters. Found no statistically significant differences between groups on cognitive measures or biographical features. Shelter staff rated sniffers as significantly more disturbed in their relationships with others, although…

  11. Glues Used in Airplane Parts

    NASA Technical Reports Server (NTRS)

    Allen, S W; Truax, T R

    1920-01-01

    This report was prepared for the National Advisory Committee for Aeronautics and presents the results of investigations conducted by the Forest Products Laboratory of the United States Forest Service on the manufacture, preparation, application, testing and physical properties of the different types of glues used in wood airplane parts.

  12. Review of Allergic and Photoallergic Contact Dermatitis from an Ingredient in a Medicament Vehicle Consisting of a Compress, Poultice, Plaster, and Tape

    PubMed Central

    Oiso, Naoki; Kawada, Akira

    2011-01-01

    The topical application of a medicament vehicle consisting of a compress, poultice, plaster, and tape containing a nonsteroidal anti-inflammatory drug or methyl salicylate is prevalent in Japan. The method is effective for conveying ingredients to the muscles via the skin for the relief of muscular pain. However, an ingredient in the occlusive vehicle can cause allergic and photoallergic contact dermatitis. We summarize cases reported over the past decade and discuss the current strategy for diminishing the risk of allergic and photoallergic contact dermatitis. PMID:21603165

  13. A novel method for creating custom shaped ballistic gelatin trainers using plaster molds.

    PubMed

    Doctor, Michael; Katz, Anne; McNamara, Shannon O; Leifer, Jessica H; Bambrick-Santoyo, Gabriela; Saul, Turandot; Rose, Keith M

    2018-03-01

    Simulation based procedural training is an effective and frequently used method for teaching vascular access techniques which often require commercial trainers. These can be prohibitively expensive, which allows for homemade trainers made of gelatin to be a more cost-effective and attractive option. Previously described trainers are often rectangular with a flat surface that is dissimilar to human anatomy. We describe a novel method to create a more anatomically realistic trainer using ballistic gelatin, household items, and supplies commonly found in an emergency department such as the plaster wrap typically used to make splints.

  14. Prosthesis Material

    NASA Technical Reports Server (NTRS)

    1995-01-01

    FAB/CAM, a subsidiary of the Harshberger Prosthetic and Orthotic Center, Inc., approached Marshall for help in replacing the heavy, fragile plaster they used to produce master molds for prosthetics. Concurrently, Marshall and Martin Marietta were creating a commercial derivative of the foam insulation used to protect the Space Shuttle External Tank from excessive heat. FAB/CAM found the foam blanks to be lighter, cheaper and easier to manufacture than plaster, resulting in lower costs to the consumer. Martin Marietta markets the foam system, MARCORE, for the prosthesis market. The system also has commercial potential in high temperature insulation and structural applications.

  15. Versatile fabrication of paper-based microfluidic devices with high chemical resistance using scholar glue and magnetic masks.

    PubMed

    Cardoso, Thiago M G; de Souza, Fabrício R; Garcia, Paulo T; Rabelo, Denilson; Henry, Charles S; Coltro, Wendell K T

    2017-06-29

    Simple methods have been developed for fabricating microfluidic paper-based analytical devices (μPADs) but few of these devices can be used with organic solvents and/or aqueous solutions containing surfactants. This study describes a simple fabrication strategy for μPADs that uses readily available scholar glue to create the hydrophobic flow barriers that are resistant to surfactants and organic solvents. Microfluidic structures were defined by magnetic masks designed with either neodymium magnets or magnetic sheets to define the patter, and structures were created by spraying an aqueous solution of glue on the paper surface. The glue-coated paper was then exposed to UV/Vis light for cross-linking to maximize chemical resistance. Examples of microzone arrays and microfluidic devices are demonstrated. μPADs fabricated with scholar glue retained their barriers when used with surfactants, organic solvents, and strong/weak acids and bases unlike common wax-printed barriers. Paper microzones and microfluidic devices were successfully used for colorimetric assays of clinically relevant analytes commonly detected in urinalysis to demonstrate the low background of the barrier material and generally applicability to sensing. The proposed fabrication method is attractive for both its ability to be used with diverse chemistries and the low cost and simplicity of the materials and process. Copyright © 2017 Elsevier B.V. All rights reserved.

  16. Stochastic capture zone analysis of an arsenic-contaminated well using the generalized likelihood uncertainty estimator (GLUE) methodology

    NASA Astrophysics Data System (ADS)

    Morse, Brad S.; Pohll, Greg; Huntington, Justin; Rodriguez Castillo, Ramiro

    2003-06-01

    In 1992, Mexican researchers discovered concentrations of arsenic in excess of World Heath Organization (WHO) standards in several municipal wells in the Zimapan Valley of Mexico. This study describes a method to delineate a capture zone for one of the most highly contaminated wells to aid in future well siting. A stochastic approach was used to model the capture zone because of the high level of uncertainty in several input parameters. Two stochastic techniques were performed and compared: "standard" Monte Carlo analysis and the generalized likelihood uncertainty estimator (GLUE) methodology. The GLUE procedure differs from standard Monte Carlo analysis in that it incorporates a goodness of fit (termed a likelihood measure) in evaluating the model. This allows for more information (in this case, head data) to be used in the uncertainty analysis, resulting in smaller prediction uncertainty. Two likelihood measures are tested in this study to determine which are in better agreement with the observed heads. While the standard Monte Carlo approach does not aid in parameter estimation, the GLUE methodology indicates best fit models when hydraulic conductivity is approximately 10-6.5 m/s, with vertically isotropic conditions and large quantities of interbasin flow entering the basin. Probabilistic isochrones (capture zone boundaries) are then presented, and as predicted, the GLUE-derived capture zones are significantly smaller in area than those from the standard Monte Carlo approach.

  17. The High-Energy Photoproduction of Light-Quark Pseudoscalar and Scalar Meson at GlueX

    NASA Astrophysics Data System (ADS)

    Zhang, Zhenyu

    The high-energy photoproduction of light-quark pseudoscalar and scalar mesons is an effective tool for understanding the properties of strong interaction in the nonperturbative regime. It has been investigated theoretically using Regge-cut phenomenology with massive quasi-particle exchange in the high-energy regime, and the linearly polarized photon beam asymmetry Σ can provide insight into the dominant production mechanism. In the low-energy region, it can provide constraints on ”background” to baryon resonance extraction. With an almost 50-year history, intensive experiments on meson photoproduction are growing vigorously at several international laboratories, such as JLab, ELSA, and MAMI. Recently the beam asymmetry Σ in high-energy π0/η photoproduction has been measured at GlueX, which is the first measurement both from the GlueX experiment and the 12 GeV upgraded JLab. The highest precision measurement of the π0 asymmetry and the first measurement of η beam asymmetry at a beam energy above 3 GeV are presented. A broad meson photoproduction project, including scalar meson a0(980)/f0(980), is under way at GlueX. In the proceedings, we report the beam asymmetry results for π0/η photoproduction at GlueX, as well as preliminary results for scalar meson photoproduction in the π0π0 and π0η channels.

  18. 9 CFR 95.9 - Glue stock; requirements for unrestricted entry.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 9 Animals and Animal Products 1 2011-01-01 2011-01-01 false Glue stock; requirements for unrestricted entry. 95.9 Section 95.9 Animals and Animal Products ANIMAL AND PLANT HEALTH INSPECTION SERVICE, DEPARTMENT OF AGRICULTURE EXPORTATION AND IMPORTATION OF ANIMALS (INCLUDING POULTRY) AND ANIMAL PRODUCTS...

  19. 9 CFR 95.9 - Glue stock; requirements for unrestricted entry.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 9 Animals and Animal Products 1 2010-01-01 2010-01-01 false Glue stock; requirements for unrestricted entry. 95.9 Section 95.9 Animals and Animal Products ANIMAL AND PLANT HEALTH INSPECTION SERVICE, DEPARTMENT OF AGRICULTURE EXPORTATION AND IMPORTATION OF ANIMALS (INCLUDING POULTRY) AND ANIMAL PRODUCTS...

  20. Antibacterial properties of propolis (bee glue).

    PubMed Central

    Grange, J M; Davey, R W

    1990-01-01

    Propolis (bee glue) was found to have antibacterial activity against a range of commonly encountered cocci and Gram-positive rods, including the human tubercle bacillus, but only limited activity against Gram-negative bacilli. These findings confirm previous reports of antimicrobial properties of this material, possibly attributable to its high flavonoid content. PMID:2182860

  1. Hearing loss in a glue sniffer.

    PubMed

    Williams, D M

    1988-10-01

    A case is presented of a 27-year-old glue sniffing woman with sensorineural hearing loss, optic atrophy and global brain damage. This form of addiction has not received much attention as a cause of otologic catastrophes, and should be borne in mind where similar cases come to the otolaryngologist.

  2. 9 CFR 95.10 - Glue stock; importations permitted subject to restrictions.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... disinfection by such method or methods as the Deputy Administrator, Veterinary Services may prescribe unless... permission by the Deputy Administrator, Veterinary Services glue stock may be stored for a temporary period... persons authorized by the Deputy Administrator, Veterinary Services so to do, or without sealing as...

  3. 9 CFR 95.10 - Glue stock; importations permitted subject to restrictions.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... disinfection by such method or methods as the Deputy Administrator, Veterinary Services may prescribe unless... permission by the Deputy Administrator, Veterinary Services glue stock may be stored for a temporary period... persons authorized by the Deputy Administrator, Veterinary Services so to do, or without sealing as...

  4. Leaf Histology--Two Modern Methods.

    ERIC Educational Resources Information Center

    Freeman, H. E.

    1984-01-01

    Two methods for examining leaf structure are presented; both methods involve use of "superglue." The first method uses the glue to form a thin, permanent, direct replica of a leaf surface on a microscope slide. The second method uses the glue to examine the three-dimensional structure of spongy mesophyll. (JN)

  5. Gluing interface qualification test results and gluing process development of the EUCLID near-infrared spectro-photometer optical assembly

    NASA Astrophysics Data System (ADS)

    Mottaghibonab, A.; Thiele, H.; Gubbini, E.; Dubowy, M.; Gal, C.; Mecsaci, A.; Gawlik, K.; Vongehr, M.; Grupp, F.; Penka, D.; Wimmer, C.; Bender, R.

    2016-07-01

    The Near Infrared Spectro-Photometer Optical assembly (NIOA) of EUCLID satellite requires high precision large lens holders with different lens materials, shapes and diameters. The aspherical lenses are glued into their separate CTE matched lens holder. The gluing of the lenses in their holder with 2K epoxy is selected as bonding process to minimize the stress in the lenses to achieve the required surface form error (SFE) performance (32nm) and lens position stability (+/-10μm) due to glue shrinkage. Adhesive shrinkage stress occurs during the glue curing at room temperature and operation in cryogenic temperatures, which might overstress the lens, cause performance loss, lens breakage or failure of the gluing interface. The selection of the suitable glue and required bonding parameters, design and qualification of the gluing interface, development and verification of the gluing process was a great challenge because of the low TRL and heritage of the bonding technology. The different material combinations (CaF2 to SS316L, LF5G15 and S-FTM16 to Titanium, SUPRASIL3001 to Invar M93), large diameter (168mm) and thin edge of the lenses, cryogenic nonoperational temperature (100K) and high performance accuracy of the lenses were the main design driver of the development. The different coefficients of thermal expansion (CTE) between lens and lens holder produce large local mechanical stress. As hygroscopic crystal calcium fluoride (CaF2) is very sensitive to moisture therefore an additional surface treatment of the gluing area is necessary. Extensive tests e.g glue handling and single lap shear tests are performed to select the suitable adhesive. Interface connection tests are performed to verify the feasibility of selected design (double pad design), injection channel, the roughness and treatment of the metal and lens interfaces, glue thickness, glue pad diameter and the gluing process. CTE and dynamic measurements of the glue, thermal cycling, damp- heat, connection shear and tension tests with all material combinations at RT and 100K are carried out to qualify the gluing interface. The gluing interface of the glued lenses in their mounts is also qualified with thermal cycling, 3D coordinate measurements before and after environmental tests, Polarimetry and vibration test of the lens assemblies. A multi-function double pad gluing tool and lens mounting tool is designed, manufactured and verified to meet the lens positioning and alignment performance of the lens in the holder which provides the possibility to glue lenses, filters, mirrors with different diameters, shapes and thickness with +/-10μm accuracy in plane, out of plane and +/-10 arcsec in tip/tilt with respect to the lens holder interface. The paper presents the glue interface qualification results, the qualification/verification methods, the developed ground support equipment and the gluing process of the EUCLID high precision large cryogenic lens mounts. Test results achieved in the test campaign demonstrate the suitability of the selected adhesive, glue pad design, interface parameters and the processes for the precise gluing of the lenses in lens holders for all lenses. The qualification models of the NIOA are successfully glued and qualified. The developed process can also be used for other glass materials e.g. MaF2 and optical black coated metallic surfaces.

  6. High-performance mussel-inspired adhesives of reduced complexity.

    PubMed

    Ahn, B Kollbe; Das, Saurabh; Linstadt, Roscoe; Kaufman, Yair; Martinez-Rodriguez, Nadine R; Mirshafian, Razieh; Kesselman, Ellina; Talmon, Yeshayahu; Lipshutz, Bruce H; Israelachvili, Jacob N; Waite, J Herbert

    2015-10-19

    Despite the recent progress in and demand for wet adhesives, practical underwater adhesion remains limited or non-existent for diverse applications. Translation of mussel-inspired wet adhesion typically entails catechol functionalization of polymers and/or polyelectrolytes, and solution processing of many complex components and steps that require optimization and stabilization. Here we reduced the complexity of a wet adhesive primer to synthetic low-molecular-weight catecholic zwitterionic surfactants that show very strong adhesion (∼50 mJ m(-2)) and retain the ability to coacervate. This catecholic zwitterion adheres to diverse surfaces and self-assembles into a molecularly smooth, thin (<4 nm) and strong glue layer. The catecholic zwitterion holds particular promise as an adhesive for nanofabrication. This study significantly simplifies bio-inspired themes for wet adhesion by combining catechol with hydrophobic and electrostatic functional groups in a small molecule.

  7. Sustained compression and healing of chronic venous ulcers.

    PubMed Central

    Blair, S. D.; Wright, D. D.; Backhouse, C. M.; Riddle, E.; McCollum, C. N.

    1988-01-01

    STUDY OBJECTIVE--Comparison of four layer bandage system with traditional adhesive plaster bandaging in terms of (a) compression achieved and (b) healing of venous ulcers. DESIGN--Part of larger randomised trial of five different dressings. SETTING--Outpatient venous ulcer clinic in university hospital. PATIENTS--(a) Pressure exerted by both bandage systems was measured in the same 20 patients. (b) Healing with the four layer bandage was assessed in 148 legs in 126 consecutive patients (mean age 71 (SE 2); range 30-96) with chronic venous ulcers that had resisted treatment with traditional bandaging for a mean of 27.2 (SE 8) months. INTERVENTIONS--(a) Four layer bandage system or traditional adhesive plaster bandaging for pressure studies; (b) four layer bandaging applied weekly for studies of healing. END POINTS--(a) Comparison of pressures achieved at the ankle for up to one week; (b) complete healing within 12 weeks. MEASUREMENTS AND MAIN RESULTS--(a) Four layer bandage produced higher initial pressures at the ankle of 42.5 (SE 1) mm Hg compared with 29.8 (1.8) for the adhesive plaster (p less than 0.001; 95% confidence interval 18.5 to 6.9). Pressure was maintained for one week with the four layer bandage but fell to 10.4 (3.5) mm Hg at 24 hours with adhesive plaster bandaging. (b) After weekly bandaging with the four layer bandage 110 of 48 venous ulcers had healed completely within 12 (mean 6.3 (0.4)) weeks. CONCLUSION--Sustained compression of over 40 mm Hg achieved with a multilayer bandage results in rapid healing of chronic venous ulcers that have failed to heal in many months of compression at lower pressures with more conventional bandages. PMID:3144330

  8. Accuracy of five implant impression technique: effect of splinting materials and methods

    PubMed Central

    Cho, Sung-Bum

    2011-01-01

    PURPOSE The aim of this study was to evaluate the effect of dimensional stability of splinting material on the accuracy of master casts. MATERIALS AND METHODS A stainless steel metal model with 6 implants embedded was used as a master model. Implant level impressions were made after square impression copings were splinted using 5 different techniques as follows. (1) Splinted with autopolymerizing resin and sectioned, reconnected to compensate polymerization shrinkage before the impression procedure. (2) Splinted with autopolymerizing resin just before impression procedure. (3) Primary impression made with impression plaster and secondary impression were made over with polyether impression material. (4) Splinted with impression plaster. (5) Splinted with VPS bite registration material. From master model, 5 impressions and 5 experimental casts, total 25 casts were made for each of 5 splinting methods. The distortion values of each splinting methods were measured using coordinate measuring machine, capable of recordings in the x-, y-, z-axes. A one-way analysis of variance (ANOVA) at a confidence level of 95% was used to evaluate the data and Tukey's studentized range test was used to determine significant differences between the groups. RESULTS Group 1 showed best accuracy followed by Group 3 & 4. Group 2 and 5 showed relatively larger distortion value than other groups. No significant difference was found between group 3, 4, 5 in x-axis, group 2, 3, 4 in y-axis and group 1, 3, 4, 5 in z-axis (P<.0001). CONCLUSION Both Splinting impression copings with autopolymerizing resin following compensation of polymerization shrinkage and splinting method with impression plaster can enhance the accuracy of master cast and impression plaster can be used simple and effective splinting material for implant impression procedure. PMID:22259700

  9. The Accuracy and Reproducibility of Linear Measurements Made on CBCT-derived Digital Models.

    PubMed

    Maroua, Ahmad L; Ajaj, Mowaffak; Hajeer, Mohammad Y

    2016-04-01

    To evaluate the accuracy and reproducibility of linear measurements made on cone-beam computed tomography (CBCT)-derived digital models. A total of 25 patients (44% female, 18.7 ± 4 years) who had CBCT images for diagnostic purposes were included. Plaster models were obtained and digital models were extracted from CBCT scans. Seven linear measurements from predetermined landmarks were measured and analyzed on plaster models and the corresponding digital models. The measurements included arch length and width at different sites. Paired t test and Bland-Altman analysis were used to evaluate the accuracy of measurements on digital models compared to the plaster models. Also, intraclass correlation coefficients (ICCs) were used to evaluate the reproducibility of the measurements in order to assess the intraobserver reliability. The statistical analysis showed significant differences on 5 out of 14 variables, and the mean differences ranged from -0.48 to 0.51 mm. The Bland-Altman analysis revealed that the mean difference between variables was (0.14 ± 0.56) and (0.05 ± 0.96) mm and limits of agreement between the two methods ranged from -1.2 to 0.96 and from -1.8 to 1.9 mm in the maxilla and the mandible, respectively. The intraobserver reliability values were determined for all 14 variables of two types of models separately. The mean ICC value for the plaster models was 0.984 (0.924-0.999), while it was 0.946 for the CBCT models (range from 0.850 to 0.985). Linear measurements obtained from the CBCT-derived models appeared to have a high level of accuracy and reproducibility.

  10. Bandwidth-Tunable Fiber Bragg Gratings Based on UV Glue Technique

    NASA Astrophysics Data System (ADS)

    Fu, Ming-Yue; Liu, Wen-Feng; Chen, Hsin-Tsang; Chuang, Chia-Wei; Bor, Sheau-Shong; Tien, Chuen-Lin

    2007-07-01

    In this study, we have demonstrated that a uniform fiber Bragg grating (FBG) can be transformed into a chirped fiber grating by a simple UV glue adhesive technique without shifting the reflection band with respect to the center wavelength of the FBG. The technique is based on the induced strain of an FBG due to the UV glue adhesive force on the fiber surface that causes a grating period variation and an effective index change. This technique can provide a fast and simple method of obtaining the required chirp value of a grating for applications in the dispersion compensators, gain flattening in erbium-doped fiber amplifiers (EDFAs) or optical filters.

  11. Detection of Gelatin Adulteration in Traditional Chinese Medicine: Analysis of Deer-Horn Glue by Rapid-Resolution Liquid Chromatography-Triple Quadrupole Mass Spectrometry

    PubMed Central

    Chen, Jia; Cheng, Xian-Long; Wei, Feng; Zhang, Qian-Qian; Li, Ming-Hua; Ma, Shuang-Cheng

    2015-01-01

    Simultaneous identification of donkey-hide gelatin and bovine-hide gelatin in deer-horn glue was established by rapid-resolution liquid chromatography-triple quadrupole mass spectrometry. Water containing 1% NH4HCO3 was used for sample dissolution and trypsin was used for hydrolysis of the gelatins. After separation by a SB-C18 reversed-phase analytical column, collagen marker peptides were detected by mass spectrometry in positive electrospray ionization mode with multiple reaction monitoring. The method was specific, precise and reliable, and suitable for detection of adulterants derived from donkey-hide gelatin and bovine-hide gelatin in deer-horn glue. PMID:26504613

  12. Sutureless Technique to Fix the Great Saphenous Vein along the Atrioventricular Groove Using Fibrin Glue in Off-Pump Coronary Artery Bypass Grafting.

    PubMed

    Ohira, Suguru; Doi, Kiyoshi; Yaku, Hitoshi

    2016-04-05

    We describe a simple method to fix the great saphenous vein graft (SVG) to the right coronary artery along the atrioventricular groove using fibrin glue in off-pump coronary artery bypass grafting (OPCAB). After completion of the proximal anastomosis, the SVG was placed along the atrioventricular groove to the acute margin. Fibrin glue was sprayed using pressurized carbon dioxide gas. A distal anastomosis was subsequently performed after rotating the heart to expose the posterior descending artery. It is a straightforward and reproducible technique to determine the optimal length of the SVG and prevent kinking or stretching of the graft, especially in OPCAB.

  13. Critical Speed of The Glass Glue Machine's Creep and Influence Factors Analysis

    NASA Astrophysics Data System (ADS)

    Yang, Jianxi; Huang, Jian; Wang, Liying; Shi, Jintai

    When automatic glass glue machine works, two questions of the machine starting vibrating and stick-slip motion are existing. These problems should be solved. According to these questions, a glue machine's model for studying stick-slip is established. Based on the dynamics system describing of the model, mathematical expression is presented. The creep critical speed expression is constructed referring to existing research achievement and a new conclusion is found. The influencing factors of stiffness, dampness, mass, velocity, difference of static and kinetic coefficient of friction are analyzed through Matlab simulation. Research shows that reasonable choice of influence parameters can improve the creep phenomenon. These all supply the theory evidence for improving the machine's motion stability.

  14. Coronary artery narrowing after aortic root reconstruction with resorcin-formalin glue.

    PubMed

    Martinelli, L; Graffigna, A; Guarnerio, M; Bonmassari, R; Disertori, M

    2000-11-01

    Severe stenosis of right and left main coronary artery ostia developed after aortic root reconstruction with gelatin-resorcin-formol glue for correction of acute type A aortic dissection. Surgical treatment of this condition required grafting of the right and left anterior descending arteries with bilateral mammary arteries on the beating heart.

  15. 75 FR 27991 - Notice of Petitions by Firms for Determination of Eligibility To Apply for Trade Adjustment...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-05-19

    ..., varnish, glue, inlay, sawing, planing, sanding equipment. Process: Plane and sand wood, cut wood pieces, do inlay, glue, sand, stain, varnish, add hardware, inspect, ship. Sioux Corporation One Sioux Plaza.... Quality Rolling & Deburring Inc....... 135 South Main Street, 5/5/2010 Quality Rolling & Deburring...

  16. Damage of Wood-Concrete Composite subjected to variable hygrometric conditions

    NASA Astrophysics Data System (ADS)

    Loulou, L.; Caré, S.; Le Roy, R.; Bornert, M.

    2010-06-01

    This paper discusses the factors influencing the durability of glued assemblies of wood and cementitious material under variable hygrometric conditions. The composite specimens are composed of cement paste connected to plywood using epoxy glue. The cement paste is subjected to autogeneous shrinkage and the wood is subjected to imbibition test. Plywood is used so that the swelling deformations due to the imbibition process are parallel to the connection plane. Swelling strains in wood are related to the water content measured by gammadensimetry technique. Global strains above and below the glue interface have been measured and have been compared to the free strains. We showed that there are restrained deformations at the glue interface and that the cement paste is damaged. Local strains have been characterized by means of the digital image correlation technique. We showed in particular that the deformations in wood are related to the microstructure of the layers of plywood and that the restrained deformations at the glue interface lead to a bending of the cement paste. In the case of strong adhesion properties, this bending induces cracking in cement paste.

  17. Glue-induced birefringence in surface-attached FBG strain sensors

    NASA Astrophysics Data System (ADS)

    Helminger, Dominik; Daitche, Alexej; Roths, Johannes

    2014-05-01

    The influence of the gluing process on the birefringence of surface-glued FBGs that were inscribed in highly birefringence (HiBi) optical fibers of type Panda was studied by monitoring the variation of the birefringence during the gluing procedure. The isothermal curing process at 100°C of the epoxy-based adhesive is characterized by the reduction of birefringence during curing. Significant transversal strain is introduced into the fiber during the cool down period, which is due to different thermal expansion coefficients of the silica and the glue. When the slow axis of the HiBi fiber is oriented parallel to the surface, the glue-induced transversal strain reduces the birefringence of the fiber by ΔB = -6.6 10-5 and when it is perpendicular to the surface, it is increased by ΔB = 1.1 10-5. It can be estimated that for conventional FBGs in single mode fibers a glue-induced birefringence in the order of ΔB = 3.4 10-5 can be expected, which has to be taken into account if in surface-mounted FBG-based strain measurements a high accuracy has to be achieved.

  18. Percutaneous Glue Embolization of a Visceral Artery Pseudoaneurysm in a Case of Sickle Cell Anemia

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gulati, Gurpreet S.; Gulati, Manpreet S.; Makharia, Govind

    2006-08-15

    Although aneurysmal complications of sickle cell anemia have been described in the intracranial circulation, visceral artery pseudoaneurysms in this disease entity have not previously been reported in the literature. Conventional treatment of visceral pseudoaneurysms has been surgical ligation or resection of the aneurysm. Transcatheter embolization has emerged as an attractive, minimally invasive alternative to surgery in the treatment of these lesions. In certain situations, however, due to the unfavorable angiographic anatomy precluding safe transcatheter embolization, direct percutaneous glue injection of the pseudoaneurysm sac may be considered to achieve successful occlusion of the sac. The procedure may be rendered safer bymore » simultaneous balloon protection of the parent artery. We describe this novel treatment modality in a case of inferior pancreaticoduodenal artery pseudoaneurysm in a patient with sickle cell anemia. Although a complication in the form of glue reflux into the parent vessel occurred that necessitated surgery, this treatment modality may be used in very selected cases (where conventional endovascular embolization techniques are not applicable) after careful selection of the balloon diameter and appropriate concentration of the glue-lipiodol mixture.« less

  19. Endovascular embolization of varicoceles using n-butyl cyanoacrylate (NBCA) glue

    PubMed Central

    Pietura, Radosław; Toborek, Michał; Dudek, Aneta; Boćkowska, Agata; Janicka, Joanna; Piekarski, Paweł

    2013-01-01

    Summary Background: Varicoceles are abnormally dilated veins within the pampiniform plexus. They are caused by reflux of blood in the internal spermatic vein. The incidence of varicoceles is approximately 10–15% of the adolescent male population. The etiology of varicoceles is probably multifactorial. The diagnosis is based on Doppler US. Treatment could be endovascular or surgical. The aim of the study was to describe and evaluate a novel method of endovascular embolization of varicoceles using n-butyl cyanoacrylate (NBCA) glue. Material/Methods: 17 patients were subjected to endovascular treatment of varicoceles using NBCA. A 2.8 Fr microcatheter and a 1:1 mixture of NBCA and lipiodol were used for embolization of the spermatic vein. Results: All 17 procedures were successful. There were no complications. Discussion: Embolization of varicoceles using NBCA glue is efficient and safe for all patients. The method should be considered as a method of choice in all patients. Phlebography and Valsalva maneuver are crucial for technical success and avoidance of complications. Conclusions: Endovascular treatment of varicoceles using NBCA glue is very effective and safe. PMID:23807881

  20. Glue Spin and Helicity in the Proton from Lattice QCD.

    PubMed

    Yang, Yi-Bo; Sufian, Raza Sabbir; Alexandru, Andrei; Draper, Terrence; Glatzmaier, Michael J; Liu, Keh-Fei; Zhao, Yong

    2017-03-10

    We report the first lattice QCD calculation of the glue spin in the nucleon. The lattice calculation is carried out with valence overlap fermions on 2+1 flavor domain-wall fermion gauge configurations on four lattice spacings and four volumes including an ensemble with physical values for the quark masses. The glue spin S_{G} in the Coulomb gauge in the modified minimal subtraction (MS[over ¯]) scheme is obtained with one-loop perturbative matching. We find the results fairly insensitive to lattice spacing and quark masses. We also find that the proton momentum dependence of S_{G} in the range 0≤|p[over →]|<1.5  GeV is very mild, and we determine it in the large-momentum limit to be S_{G}=0.251(47)(16) at the physical pion mass in the MS[over ¯] scheme at μ^{2}=10  GeV^{2}. If the matching procedure in large-momentum effective theory is neglected, S_{G} is equal to the glue helicity measured in high-energy scattering experiments.

  1. [Research of repairing rabbit knee joint cartilage defect by compound material of fibrin glue and decalcified bone matrix (DBM) and chondrocytes].

    PubMed

    He, Jie; Yang, Xiang; Yue, Peng-ju; Wang, Guan-yu; Guo, Ting; Zhao, Jian-ning

    2009-07-01

    To investigate the feasibility and effectivity of using compound material of fibrin glue and DBM as scaffolds for cartilage tissue engineering. Chondrocytes isolated from articular cartilage were seeded into prepared scaffolds, after incubation for 4 weeks in vitro. Chondrocytes and fibrin glue and DBM constructs were implanted in the joint cave of rabbit. The specimens were excised at the 4th, 8th, 12th week, examined grossly analyzed by haematoxylin cosine, toluidine blues staining and type II collagen immunohistochemistry reaction. Wakitani score was counted to evaluate the repairing effect. Grossly analysis showed some ivory tissue filled the caves after 4 weeks and the caves were full filled with smooth surface after 12 weeks. The microscope showed a good deal of chondrocytes appeared after 8 weeks and more type II collagen than 4 weeks. Twelve weeks later, cartilage lacuna could be observed. The cells arrangement and the amount of type II collagen both showed the same as the natural one. Complicated material of fibrin glue and DBM as scaffolds can be used as scaffolds for cartilage tissue engineering.

  2. Limiting hazardous noise exposure from noisy toys: simple, sticky solutions.

    PubMed

    Weinreich, Heather M; Jabbour, Noel; Levine, Samuel; Yueh, Bevan

    2013-09-01

    To assess noise levels of toys from the Sight & Hearing Association (SHA) 2010 Noisy Toys List and evaluate the change in noise of these toys after covering the speakers with tape or glue. One Group Pretest-Posttest Design. SHA 2010 Toys List (n = 18) toys were tested at distances of 0 and 25 cm from sound source in a soundproof booth using a digital sound-level meter. The dBA level of sound produced by toy was obtained. Toys with speakers (n = 16) were tested before and after altering speakers with plastic packing tape or nontoxic glue. Mean noise level for non-taped toys at 0 and 25 cm was 107.6 dBA (SD ± 8.5) and 82.5 dBA (SD ± 8.8), respectively. With tape, there was a statistically significant decrease in noise level at 0 and 25 cm: 84.2 dBA and 68.2 dBA (P <0.001). With glue, there was a statistically significant decrease in noise level at 0 cm and 25 cm: 79.7 dBA and 66.4 dBA (P <0.001). Both tape and glue significantly decreased the noise level produced by the toys. However, there was no significant difference between tape or glue. Overall, altering the toy can significantly decrease the sound a child may experience when playing with toys. However, some toys, even after altering, still produce sound levels that may be considered dangerous. Copyright © 2013 The American Laryngological, Rhinological and Otological Society, Inc.

  3. Reduction of bone resorption by the application of fibrin glue in the reconstruction of the alveolar cleft.

    PubMed

    Segura-Castillo, José L; Aguirre-Camacho, Humberto; González-Ojeda, Alejandro; Michel-Perez, Jorge

    2005-01-01

    A major complication in 30% to 75% of cases of surgical treatment of alveolar cleft is resorption of the bone graft. A treatment alternative is the application of fibrin glue, which has the capacity to favor the integration of the graft. The main objective of the study was to evaluate if the use of the fibrin glue reduces bone resorption when it is applied locally. The authors designed a randomized clinical trial. Patients were divided into two groups: group 1, fibrin glue; and group 2, control. Pre- and postoperative graft volume, bone density, bone quality (Lekholm and Zarb, and Norton and Gamble classifications), and postoperative complications were evaluated. The follow-up for all patients was 3 months after discharge. Twenty-seven patients were surgically treated, 13 in group 1 and 14 in group 2. Group 1 had increased graft volume compared with group 2 (64.32 cm v 21.70 cm; P < 0.0001). Bone density was higher in group 1 than in group 2 (396.57 v 245.68; P > 0.076). Bone quality was type 1, 2 and 3 and 4 in group 1. Resorption in group 2 was 62.26%; in group 1, it was 29.72% (P > 0.081). The observed complications were infection and dehiscence of sutures (P > 0.537). The authors conclude that the fibrin glue significantly diminishes bone resorption, allowing improved graft integration and quality.

  4. Autologous fibrin glue: the last step in operative hemostasis.

    PubMed

    Tawes, R L; Sydorak, G R; DuVall, T B

    1994-08-01

    Fibrin glue may be the perfect hemostatic agent for operative use as it seals in minutes, has no tissue toxicity, reabsorbs, and promotes local tissue growth and repair. Use in the United States has been limited because of lack of Food and Drug Administration approval of the commercial homologous products, lack of a concentrated source of fibrinogen, and because of the potential for viral transmission, particularly hepatitis, with pooled homologous plasma and cryoprecipitate-based methods. Autologous fibrin glue (AFG) obviates these problems. During the past year, we obtained AFG through the same routine predonation procedure as with red blood cells before major elective surgery. Intraoperatively, we made AFG from the platelet-rich plasma derived from the Plasma-Saver. Our experience has been with 36 patients undergoing aortic, thoracoabdominal, and thoracic surgery, as well as patch graft angioplasty cases. Fibrin glue formation mimics the final stage in the coagulation cascade. The AFG from predonation acts more like an epoxy glue, while the AFG made during surgery is less viscous and acts more like a sealant because of the lesser concentration of fibrinogen in platelet-rich plasma. In emergencies, however, the intraoperative method is obviously the only choice available, and it is a useful adjunct to hemostasis at the end of the procedure. The technique will be described. This relatively new approach to hemostasis should gain popularity because it is easy and fairly inexpensive to produce, and because the patient's own blood is used.

  5. Use of Cyanoacrylate Glue Casting for Stabilization of Periocular Skin Grafts and Flaps.

    PubMed

    Jackson, Colette M; Nguyen, Michelle; Mancini, Ronald

    To examine a novel technique for periocular skin graft and flap stabilization using cyanoacrylate glue applied to the host bed around the perimeter of the graft or flap to create an immobile cast in the immediate postoperative period to promote successful graft take and stable anatomic position. Retrospective review was performed of a single surgeon's patients who underwent periocular skin graft or flap between August 1, 2011, and February 29, 2016, in which cyanoacrylate glue was applied postoperatively for graft stabilization. Data examined included indication for procedure, location and size of graft, postoperative complications, and length of follow up postoperatively. Of 164 cases reviewed, 9 cases were identified in which cyanoacrylate glue was used as the sole means of graft or flap stabilization. Indications for surgery included repair of cicatricial ectropion (3 cases) and repair of Mohs defect status after excision of basal or squamous cell carcinoma (6 cases). All cases involved reformation of the lower eyelid. Five cases employed full-thickness skin grafts and 4 cases employed adjacent tissue rearrangement. Size of defect repaired ranged from 8 mm to 35 mm when largest diameter was measured. Complications included mild residual ectropion or mild punctal ectropion in 2 patients who was asymptomatic and did not require further surgery. No cases were complicated by hematoma, infection, or graft necrosis. Cyanoacrylate glue can be used to successfully stabilize skin grafts and flaps in the immediate postoperative period.

  6. Control of DNA hybridization by photoswitchable molecular glue.

    PubMed

    Dohno, Chikara; Nakatani, Kazuhiko

    2011-12-01

    Hybridization of DNA is one of the most intriguing events in molecular recognition and is essential for living matter to inherit life beyond generations. In addition to the function of DNA as genetic material, DNA hybridization is a key to control the function of DNA-based materials in nanoscience. Since the hybridization of two single stranded DNAs is a thermodynamically favorable process, dissociation of the once formed DNA duplex is normally unattainable under isothermal conditions. As the progress of DNA-based nanoscience, methodology to control the DNA hybridization process has become increasingly important. Besides many reports using the chemically modified DNA for the regulation of hybridization, we focused our attention on the use of a small ligand as the molecular glue for the DNA. In 2001, we reported the first designed molecule that strongly and specifically bound to the mismatched base pairs in double stranded DNA. Further studies on the mismatch binding molecules provided us a key discovery of a novel mode of the binding of a mismatch binding ligand that induced the base flipping. With these findings we proposed the concept of molecular glue for DNA for the unidirectional control of DNA hybridization and, eventually photoswitchable molecular glue for DNA, which enabled the bidirectional control of hybridization under photoirradiation. In this tutorial review, we describe in detail how we integrated the mismatch binding ligand into photoswitchable molecular glue for DNA, and the application and perspective in DNA-based nanoscience.

  7. Healing of rabbit calvarial critical-sized defects using autogenous bone grafts and fibrin glue.

    PubMed

    Lappalainen, Olli-Pekka; Korpi, Riikka; Haapea, Marianne; Korpi, Jarkko; Ylikontiola, Leena P; Kallio-Pulkkinen, Soili; Serlo, Willy S; Lehenkari, Petri; Sándor, George K

    2015-04-01

    This study aimed to evaluate ossification of cranial bone defects comparing the healing of a single piece of autogenous calvarial bone representing a bone flap as in cranioplasty compared to particulated bone slurry with and without fibrin glue to represent bone collected during cranioplasty. These defect-filling materials were then compared to empty control cranial defects. Ten White New Zealand adult male rabbits had bilateral critical-sized calvarial defects which were left either unfilled as control defects or filled with a single full-thickness piece of autogenous bone, particulated bone, or particulated bone combined with fibrin glue. The defects were left to heal for 6 weeks postoperatively before termination. CT scans of the calvarial specimens were performed. Histomorphometric assessment of hematoxylin-eosin- and Masson trichrome-stained specimens was used to analyze the proportion of new bone and fibrous tissue in the calvarial defects. There was a statistically significant difference in both bone and soft tissue present in all the autogenous bone-grafted defect sites compared to the empty negative control defects. These findings were supported by CT scan findings. While fibrin glue combined with the particulated bone seemed to delay ossification, the healing was more complete compared to empty control non-grafted defects. Autogenous bone grafts in various forms such as solid bone flaps or particulated bone treated with fibrin glue were associated with bone healing which was superior to the empty control defects.

  8. Egg-laying behavior and morphological and chemical characterization of egg surface and egg attachment glue of the digger wasp Ampulex compressa (Hymenoptera, Ampulicidae).

    PubMed

    Gnatzy, Werner; Volknandt, Walter; Dzwoneck, Anja

    2018-01-01

    For providing their offspring females of the digger wasp species Ampulex compressa hunt cockroaches, paralyze them and attach as a rule one egg to the coxa of one of the mid legs of their prey. We observed the egg-laying behavior and examined with light- and scanning microscopy (i) nearly mature eggs from ovaries of freshly dissected females and (ii) eggs immediately after their deposition on the coxae of their prey. The length of the white bean-shaped eggs varied between 2.2 and 3.0 mm, their diameter between 0.66 and 0.72 mm, and their weight between 345 and 832 μg. The surface of fresh, untreated eggs shows even at higher magnifications (>20.000×) a smooth appearance. However, after conventional fixation, dehydration with ethyl-alcohol and critical-point drying the egg-surface exhibited a little bit texture. The eggs are at two-third of their underside glued to the coxa of the prey. With the naked eye the glue appears as a compact mass. The eggs may be mechanically removed from the substrate (their attachment site); however, in doing so the viscous attachment glue appears in a more fibrous consistence. The polypeptide composition washed off the egg surface and the glue revealed no similarities, whereas the molecular mass of two polypeptides were similar between glue and the Dufour's gland contents. Copyright © 2017. Published by Elsevier Ltd.

  9. A comparison of the application of fibrin glue and adhesive film for repair of anastomotic leaks in the rat.

    PubMed

    Ayhan, Baris; Erikoglu, Mehmet; Tavli, Süleyman S; Toy, Hatice

    2012-08-04

    Anastomotic leaks constitute one of the most serious intraoperative complications and although many studies have been devoted to finding a solution for this problem, none of them has yet been able offer a decisive, successful method. In this study, the ability of fibrin glue and adhesive film to repair anastomotic leaks in an experimental model was compared. The sample comprised four groups of seven rats: Group 1 (Control): the distal colon was transected and anastomosis was performed. Group 2 (Primary repair): incomplete anastomosis produced a leak that was closed by primary repair on day 3. Group 3 (Fibrin glue): incomplete anastomosis produced a leak that was closed by primary repair and fibrin glue applied on day 3. Group 4 (Adhesive film): incomplete anastomosis produced a leak that was closed by primary repair and adhesive film was applied on day 3. The rats were sacrificed on day 6 following anastomosis. Anastomotic blast compressions were measured and fibroblast activation, inflammation, neovascularization and levels of collagen were evaluated. The results from Group 4 showed that blast compression values were high and statistically significantly increased over control values (p < 0.05). Inflammation in Group 2 was significantly higher than the other groups (p < 0.05). No significant differences were detected in the comparison of the groups regarding the other scoring criteria (p > 0.05). Adhesive film is more effective in reducing anastomotic leakage than fibrin glue.

  10. Injectable tissue-engineered cartilage using commercially available fibrin glue.

    PubMed

    Cakmak, Ozcan; Babakurban, Seda T; Akkuzu, Hatice G; Bilgi, Selcuk; Ovalı, Ercüment; Kongur, Merve; Altintas, Hande; Yilmaz, Bayram; Bilezikçi, Banu; Celik, Zerrin Y; Yakicier, Mustafa C; Sahin, Feride I

    2013-12-01

    To achieve injectable tissue-engineered cartilage using a commercially available fibrin sealant, and to determine the most suitable fibrin glue concentration, cartilage source, and cultured chondrocyte concentration. Animal research. A total of 28 immunocompetent New Zealand white rabbits were divided into four groups. The cultured chondrocytes from different anatomical sources carried in fibrin glue with and without aprotinin in different concentrations of fibrinogen and thrombin (Tisseell), were injected into forehead and interocular regions of the rabbits. The new tissue formation was harvested at 8 weeks and analyzed through gross and histological analysis. The new tissue formations were found in round, elliptical, and flat forms. The mean value of Tisseell and cell suspension was 0.8 cc in all of the rabbits' injection regions, but the mean volume of the samples in which immature cartilage matrix and mature cartilage was 0.1 cc. In the 20 of the 55 injection regions of rabbits (36, 36%), mature and/or immature cartilage formation were observed. We observed inflammatory reactions, abscess formation, and foreign body reactions around the new cartilage tissue of tissue-engineered cartilage. The comparison of results using different cartilage sources, chondrocyte concentrations, or different fibrin glue concentrations did not show any significant difference. We observed that changing the concentrations of ingredients of commercially available fibrin glue, the source of the cartilage, or the cultured chondrocyte concentration did not have significant effect on neocartilage formation. Copyright © 2013 The American Laryngological, Rhinological and Otological Society, Inc.

  11. Lessons learned from laser tissue soldering and fibrin glue pyeloplasty in an in vivo porcine model.

    PubMed

    Barrieras, D; Reddy, P P; McLorie, G A; Bägli, D; Khoury, A E; Farhat, W; Lilge, L; Merguerian, P A

    2000-09-01

    We compared sutured pyeloplasty to 2 newer techniques of tissue anastomosis, including laser soldered pyeloplasty using a diode laser with 50% albumin solder mixed with indocyanine green and fibrin glue. We performed 53 pyeloplasties in 50 pigs using suture, laser or fibrin glue. In the immediate group anastomotic leak pressure was measured immediately postoperatively, and then animals were euthanized. At 1, 3 and 4 weeks postoperatively a pressure flow study at 10 cc per minute in cm. H2O was performed, and tissue was sent for histological and collagen content analysis. In the immediate studies laser soldering achieved a significantly higher mean anastomotic leak pressure (50.5 +/- 15.1 cm. H2O) than sutured (17.3 +/- 5.4) or fibrin glued (3.5 +/- 1.5) repairs. In the 1, 2 and 4-week studies animals in the sutured pyeloplasty group had no complications, and all pressure flow studies except 1 were normal. However, in the laser soldered groups we observed 8 urinomas in 19 animals, and most occurred during the first part of our study. This complication was prevented by stopping urine flow at the anastomotic site at laser irradiation and by improving application of the solder. Of the 11 animals in which pressure flow studies were performed only 2 were obstructed. Of the 7 chronic fibrin glue group 4 animals had urinomas and 2 had unobstructed pressure flow studies. Histological studies and immunohistochemical staining for collagen showed no differences in collagen distribution among the 3 procedures. Laser soldering and fibrin glue pyeloplasties are not superior in the long-term compared to sutured pyeloplasty. Fibrin glue in our animal model had the highest failure rate. Further improvements in the technical aspect of laser tissue welding need to be made to benefit from its theoretical advantages in minimally invasive surgery.

  12. Mesh fixation in laparoscopic incisional hernia repair: glue fixation provides attachment strength similar to absorbable tacks but differs substantially in different meshes.

    PubMed

    Rieder, Erwin; Stoiber, Martin; Scheikl, Verena; Poglitsch, Marcus; Dal Borgo, Andrea; Prager, Gerhard; Schima, Heinrich

    2011-01-01

    Laparoscopic ventral hernia repair has gained popularity among minimally invasive surgeons. However, mesh fixation remains a matter of discussion. This study was designed to compare noninvasive fibrin-glue attachment with tack fixation of meshes developed primarily for intra-abdominal use. It was hypothesized that particular mesh structures would substantially influence detachment force. For initial evaluation, specimens of laminated polypropylene/polydioxanone meshes were anchored to porcine abdominal walls by either helical titanium tacks or absorbable tacks in vitro. A universal tensile-testing machine was used to measure tangential detachment forces (TF). For subsequent experiments of glue fixation, polypropylene/polydioxanone mesh and 4 additional meshes with diverse particular mesh structure, ie, polyvinylidene fluoride/polypropylene mesh, a titanium-coated polypropylene mesh, a polyester mesh bonded with a resorbable collagen, and a macroporous condensed PTFE mesh were evaluated. TF tests revealed that fibrin-glue attachment was not substantially different from that achieved with absorbable tacks (median TF 7.8 Newton [N], range 1.3 to 15.8 N), but only when certain open porous meshes (polyvinylidene fluoride/polypropylene mesh: median 6.2 N, range 3.4 to 10.3 N; titanium-coated polypropylene mesh: median 5.2 N, range 2.1 to 11.7 N) were used. Meshes coated by an anti-adhesive barrier (polypropylene/polydioxanone mesh: median 3.1 N, range 1.7 to 5.8 N; polyester mesh bonded with a resorbable collagen: median 1.3 N, range 0.5 to 1.9 N), or the condensed PTFE mesh (median 3.1 N, range 2.1 to 7.0 N) provided a significantly lower TF (p < 0.01). Fibrin glue appears to be an appealing noninvasive option for mesh fixation in laparoscopic ventral hernia repair, but only if appropriate meshes are used. Glue can also serve as an adjunct to mechanical fixation to reduce the number of invasive tacks. Copyright © 2010 American College of Surgeons. Published by Elsevier Inc. All rights reserved.

  13. Treatment of wrist and hand fractures with natural magnets: preliminary report.

    PubMed

    Costantino, Cosimo; Pogliacomi, Francesco; Passera, Francesco; Concari, Galeazzo

    2007-12-01

    The Authors, after having defined the phenomenon and the biological characteristics of natural magnets, evaluate their ability in accelerating the formation of bone callus in hand and wrist fractures compared to treatment with immobilization in a plaster cast. Forty patients (4 females and 37 males) between 20 and 86 years of age were treated. A small natural magnet was inserted in each of the plaster casts (diameter: 2cm, height: 0.5cm) made of 4 blocks in Neodymium-Iron-Boron, capable of generating 4 magnetic poles (2 positive and 2 negative) of diagonal alternate polarity that produced a symmetric, quadruple static magnetic field. The created magnetic flow was wavelike, concentrated in one direction, and developed a force up to 12,500 gauss. From this study it has emerged that inserting a quadruple magnet in a plaster cast in hand and wrist fractures results in the formation of bone callus in an average time that is 35% inferior to the "standard" time. Accelerating the healing of the fracture is important since it reduces immobilization time for the joints involved, avoiding subsequent weakness and stiffness and allowing the patient to begin rehabilitative physiotherapy sooner, which permits a faster functional recovery.

  14. The Aspects About of Objectively Appraisals of Modeling Gypsum Quality and Composites of Phonic-Absorbent and Orthopedic on Base of Gypsum

    NASA Astrophysics Data System (ADS)

    Pop, P. A.; Ungur, P. A.; Lazar, L.; Marcu, F.

    2009-11-01

    The EU Norms about of protection environment, outside and inside ambient, and human health demands has lead at obtain of new materials on the base of airborne material, with high thermo and phonic-absorbent properties, porous and lightweight. The α and β-modeling gypsum plaster quality and lightweight depend on many factors as: fabrication process, granulation, roast temperature, work temperature, environment, additives used, breakage, etc. Also, the objectively appraisal of modeling gypsum quality depends of proper tests methods selection, which are legislated in norms, standards and recommendations. In Romanian Standards SR EN 13279-1/2005 and SR EN 13279-2/2005, adaptable from EU Norms EN 13279-1/2004 and EN 13279-2/2004, the characteristics gypsum family tests are well specification, as: granule-metric analysis, determination of water/plaster ratio, setting time, mechanical characteristics, adhesions and water restrain. For plaster with special use (phonic-absorbent and orthopedic materials, etc.) these determinations are not concluding, being necessary more parameters finding, as: elastic constant, phonic-absorbent coefficient, porosity, working, etc., which is imposed the completion of norms and standards with new determinations.

  15. Tooth-size discrepancy: A comparison between manual and digital methods

    PubMed Central

    Correia, Gabriele Dória Cabral; Habib, Fernando Antonio Lima; Vogel, Carlos Jorge

    2014-01-01

    Introduction Technological advances in Dentistry have emerged primarily in the area of diagnostic tools. One example is the 3D scanner, which can transform plaster models into three-dimensional digital models. Objective This study aimed to assess the reliability of tooth size-arch length discrepancy analysis measurements performed on three-dimensional digital models, and compare these measurements with those obtained from plaster models. Material and Methods To this end, plaster models of lower dental arches and their corresponding three-dimensional digital models acquired with a 3Shape R700T scanner were used. All of them had lower permanent dentition. Four different tooth size-arch length discrepancy calculations were performed on each model, two of which by manual methods using calipers and brass wire, and two by digital methods using linear measurements and parabolas. Results Data were statistically assessed using Friedman test and no statistically significant differences were found between the two methods (P > 0.05), except for values found by the linear digital method which revealed a slight, non-significant statistical difference. Conclusions Based on the results, it is reasonable to assert that any of these resources used by orthodontists to clinically assess tooth size-arch length discrepancy can be considered reliable. PMID:25279529

  16. The use of tissue glue in prominent ear correction surgery.

    PubMed

    Patel, Animesh J K; Price, Richard D

    2011-04-01

    Cyanoacrylate tissue glues have been used for many years in otoplasty and specific indications for its use are as described. As well as being an effective means of dressing the postauricular suture line, its use in gluing the pinna back to the postauricular skin may negate the use of the head bandage in the postoperative period.

  17. Gravity: The Glue of the Universe. History and Activities.

    ERIC Educational Resources Information Center

    Gilbert, Harry; Smith, Diana Gilbert

    This book presents a story of the history of gravity, the glue of the universe, and is based on two premises: (1) an understanding of mathematics is not required to grasp the concepts and implications of relativity; and (2) relativity has altered forever the perceptions of gravity, space, time, and how the universe works. A narrative text section…

  18. The GlueX Experiment: First Results

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fanelli, Cristiano

    GlueX is a nuclear physics experiment located at the Thomas Jefferson National Accelerator Facility designed to study and understand the nature of confinement in QCD by mapping the spectrum of exotic mesons. The experiment will be able to probe new areas by using photoproduction, i.e. the scattering on nucleon of ~9 GeV linearly polarized photons derived from the recently upgraded CEBAF with a 12 GeV electron beam. Spring 2016 has been characterized by a continued detector commissioning and initial running at the full design energy. The current status of the GlueX detector performance and data collection will be discussed, withmore » a brief overview of first physics results, future run plans, and long term upgrades.« less

  19. Glue, steam and Clarivein--Best practice techniques and evidence.

    PubMed

    Whiteley, Mark S

    2015-11-01

    In July 2013, the National Institute of Health and Clinical Excellence (NICE) recommended "endothermal" ablation (meaning endovenous thermal ablation) is the first line treatment for truncal venous reflux in varicose veins. The initial endovenous thermoablation devices were radiofrequency ablation and endovenous laser ablation. More recently, Glue (cyanoacrylate), endovenous steam and Clarivein (mechanochemical ablation or MOCA) have entered the market as new endovenous techniques for the treatment of varicose veins. Glue and Clarivein do not require tumescent anaesthesia and do not use heat and therefore termed non-tumescent non-thermal (NTNT). Steam both requires tumescence and is also a thermal technique (TT). This article reviews the current position of these 3 new technologies in the treatment of varicose veins. © The Author(s) 2015.

  20. Fabrication of a microfluidic chip by UV bonding at room temperature for integration of temperature-sensitive layers

    NASA Astrophysics Data System (ADS)

    Schlautmann, S.; Besselink, G. A. J.; Radhakrishna Prabhu, G.; Schasfoort, R. B. M.

    2003-07-01

    A method for the bonding of a microfluidic device at room temperature is presented. The wafer with the fluidic structures was bonded to a sensor wafer with gold pads by means of adhesive bonding, utilizing an UV-curable glue layer. To avoid filling the fluidic channels with the glue, a stamping process was developed which allows the selective application of a thin glue layer. In this way a microfluidic glass chip was fabricated that could be used for performing surface plasmon resonance measurements without signs of leakage. The advantage of this method is the possibility of integration of organic layers as well as other temperature-sensitive layers into a microfluidic glass device.

  1. In situ precise electrospinning of medical glue fibers as nonsuture dural repair with high sealing capability and flexibility.

    PubMed

    Lv, Fu-Yan; Dong, Rui-Hua; Li, Zhao-Jian; Qin, Chong-Chong; Yan, Xu; He, Xiao-Xiao; Zhou, Yu; Yan, Shi-Ying; Long, Yun-Ze

    In this work, we propose an in situ precise electrospinning of medical glue fibers onto dural wound for improving sealing capability, avoiding tissue adhesion, and saving time in dural repair. N-octyl-2-cyanoacrylate, a commercial tissue adhesive (medical glue), can be electrospun into ultrathin fibrous film with precise and homogeneous deposition by a gas-assisted electrospinning device. The self-assembled N-octyl-2-cyanoacrylate film shows high compactness and flexibility owing to its fibrous structure. Simulation experiments on egg membranes and goat meninges demonstrated that this technology can repair small membrane defects quickly and efficiently. This method may have potential application in dural repair, for example, working as an effective supplementary technique for conventional dura suture.

  2. Robust and stretchable indium gallium zinc oxide-based electronic textiles formed by cilia-assisted transfer printing

    PubMed Central

    Yoon, Jongwon; Jeong, Yunkyung; Kim, Heeje; Yoo, Seonggwang; Jung, Hoon Sun; Kim, Yonghun; Hwang, Youngkyu; Hyun, Yujun; Hong, Woong-Ki; Lee, Byoung Hun; Choa, Sung-Hoon; Ko, Heung Cho

    2016-01-01

    Electronic textile (e-textile) allows for high-end wearable electronic devices that provide easy access for carrying, handling and using. However, the related technology does not seem to be mature because the woven fabric hampers not only the device fabrication process directly on the complex surface but also the transfer printing of ultrathin planar electronic devices. Here we report an indirect method that enables conformal wrapping of surface with arbitrary yet complex shapes. Artificial cilia are introduced in the periphery of electronic devices as adhesive elements. The cilia also play an important role in confining a small amount of glue and damping mechanical stress to maintain robust electronic performance under mechanical deformation. The example of electronic applications depicts the feasibility of cilia for ‘stick-&-play' systems, which provide electronic functions by transfer printing on unconventional complex surfaces. PMID:27248982

  3. High-performance mussel-inspired adhesives of reduced complexity

    PubMed Central

    Ahn, B. Kollbe; Das, Saurabh; Linstadt, Roscoe; Kaufman, Yair; Martinez-Rodriguez, Nadine R.; Mirshafian, Razieh; Kesselman, Ellina; Talmon, Yeshayahu; Lipshutz, Bruce H.; Israelachvili, Jacob N.; Waite, J. Herbert

    2015-01-01

    Despite the recent progress in and demand for wet adhesives, practical underwater adhesion remains limited or non-existent for diverse applications. Translation of mussel-inspired wet adhesion typically entails catechol functionalization of polymers and/or polyelectrolytes, and solution processing of many complex components and steps that require optimization and stabilization. Here we reduced the complexity of a wet adhesive primer to synthetic low-molecular-weight catecholic zwitterionic surfactants that show very strong adhesion (∼50 mJ m−2) and retain the ability to coacervate. This catecholic zwitterion adheres to diverse surfaces and self-assembles into a molecularly smooth, thin (<4 nm) and strong glue layer. The catecholic zwitterion holds particular promise as an adhesive for nanofabrication. This study significantly simplifies bio-inspired themes for wet adhesion by combining catechol with hydrophobic and electrostatic functional groups in a small molecule. PMID:26478273

  4. The effects of ionic strength and organic matter on virus inactivation at low temperatures: general likelihood uncertainty estimation (GLUE) as an alternative to least-squares parameter optimization for the fitting of virus inactivation models

    NASA Astrophysics Data System (ADS)

    Mayotte, Jean-Marc; Grabs, Thomas; Sutliff-Johansson, Stacy; Bishop, Kevin

    2017-06-01

    This study examined how the inactivation of bacteriophage MS2 in water was affected by ionic strength (IS) and dissolved organic carbon (DOC) using static batch inactivation experiments at 4 °C conducted over a period of 2 months. Experimental conditions were characteristic of an operational managed aquifer recharge (MAR) scheme in Uppsala, Sweden. Experimental data were fit with constant and time-dependent inactivation models using two methods: (1) traditional linear and nonlinear least-squares techniques; and (2) a Monte-Carlo based parameter estimation technique called generalized likelihood uncertainty estimation (GLUE). The least-squares and GLUE methodologies gave very similar estimates of the model parameters and their uncertainty. This demonstrates that GLUE can be used as a viable alternative to traditional least-squares parameter estimation techniques for fitting of virus inactivation models. Results showed a slight increase in constant inactivation rates following an increase in the DOC concentrations, suggesting that the presence of organic carbon enhanced the inactivation of MS2. The experiment with a high IS and a low DOC was the only experiment which showed that MS2 inactivation may have been time-dependent. However, results from the GLUE methodology indicated that models of constant inactivation were able to describe all of the experiments. This suggested that inactivation time-series longer than 2 months were needed in order to provide concrete conclusions regarding the time-dependency of MS2 inactivation at 4 °C under these experimental conditions.

  5. Collagen-Based Fillers as Alternatives to Cyanoacrylate Glue for the Sealing of Large Corneal Perforations.

    PubMed

    Samarawickrama, Chameen; Samanta, Ayan; Liszka, Aneta; Fagerholm, Per; Buznyk, Oleksiy; Griffith, May; Allan, Bruce

    2018-05-01

    To describe the use of collagen-based alternatives to cyanoacrylate glue for the sealing of acute corneal perforations. A collagen analog comprising a collagen-like peptide conjugated to polyethylene glycol (CLP-PEG) and its chemical crosslinker were tested for biocompatibility. These CLP-PEG hydrogels, which are designed to act as a framework for corneal tissue regeneration, were then tested as potential fillers in ex vivo human corneas with surgically created full-thickness perforations. Bursting pressures were measured in each of 3 methods (n = 10 for each condition) of applying a seal: 1) cyanoacrylate glue with a polyethylene patch applied ab externo (gold standard); 2) a 100-μm thick collagen hydrogel patch applied ab interno, and 3) the same collagen hydrogel patch applied ab interno supplemented with CLP-PEG hydrogel molded in situ to fill the remaining corneal stromal defect. Cyanoacrylate gluing achieved a mean bursting pressure of 325.9 mm Hg, significantly higher than the ab interno patch alone (46.3 mm Hg) and the ab interno patch with the CLP-PEG filler (86.6 mm Hg). All experimental perforations were sealed effectively using 100 μm hydrogel sheets as an ab interno patch, whereas conventional ab externo patching with cyanoacrylate glue failed to provide a seal in 30% (3/10) cases. An ab interno patch system using CLP-PEG hydrogels designed to promote corneal tissue regeneration may be a viable alternative to conventional cyanoacrylate glue patching for the treatment of corneal perforation. Further experimentation and material refinement is required in advance of clinical trials.

  6. Risk factor analysis for massive lymphatic ascites after laparoscopic retroperitonal lymphadenectomy in gynecologic cancers and treatment using intranodal lymphangiography with glue embolization

    PubMed Central

    2016-01-01

    Objective To evaluate risk factors for massive lymphatic ascites after laparoscopic retroperitoneal lymphadenectomy in gynecologic cancer and the feasibility of treatments using intranodal lymphangiography (INLAG) with glue embolization. Methods A retrospective analysis of 234 patients with gynecologic cancer who received laparoscopic retroperitonal lymphadenectomy between April 2006 and November 2015 was done. In June 2014, INLAG with glue embolization was initiated to manage massive lymphatic ascites. All possible clinicopathologic factors related to massive lymphatic ascites were determined in the pre-INLAG group (n=163). Clinical courses between pre-INLAG group and post-INLAG group (n=71) were compared. Results In the pre-INLAG group (n=163), four patients (2.5%) developed massive lymphatic ascites postoperatively. Postoperative lymphatic ascites was associated with liver cirrhosis (three cirrhotic patients, p<0.001). In the post-INLAG group, one patient with massive lymphatic ascites had a congestive heart failure and first received INLAG with glue embolization. She had pelvic drain removed within 7 days after INLAG. The mean duration of pelvic drain and hospital stay decreased after the introduction of INLAG (13.2 days vs. 10.9 days, p=0.001; 15.2 days vs. 12.6 days, p=0.001). There was no evidence of recurrence after this procedure. Conclusion Underlying medical conditions related to the reduced effective circulating volume, such as liver cirrhosis and heart failure, may be associated with massive lymphatic ascites after retroperitoneal lymphadenectomy. INLAG with glue embolization can be an alternative treatment options to treat leaking lymphatic channels in patients with massive lymphatic leakage. PMID:27171674

  7. Contribution of glue layer into epidermis sample fluorescence dynamics

    NASA Astrophysics Data System (ADS)

    Salomatina, Elena V.; Chernova, Svetlana P.; Pravdin, Alexander B.

    2000-04-01

    In this work, the temporal behavior of autofluorescence of epidermis samples under UV-irradiation has ben studied. The samples were prepared using surface epidermis stripping technique. Fluorescence spectra and kinetic curves of fluorescence intensity have been obtained. It has been concluded that the glue composition used allows the measurement of epidermis fluorescence dynamics with the first 60 min of experiment.

  8. A unique and unexplained ricochet leak post PCI - successfully treated with intra-coronary glue.

    PubMed

    Goel, Pravin K; Syal, Sanjeev K

    2014-01-01

    We herein describe a unique case of coronary artery perforation treated with covered stent with repeat cardiac tamponade resulting out of a fresh unexplained leak from a remote vessel (Ricochet) and successfully treated with intra-coronary injection of sterile synthetic glue, cyanoacrylate. Copyright © 2014 Cardiological Society of India. Published by Elsevier B.V. All rights reserved.

  9. Composition formulas of binary eutectics

    PubMed Central

    Ma, Y. P.; Dong, D. D.; Dong, C.; Luo, L. J.; Wang, Q.; Qiang, J. B.; Wang, Y. M.

    2015-01-01

    The present paper addresses the long-standing composition puzzle of eutectic points by introducing a new structural tool for the description of short-range-order structural unit, the cluster-plus-glue-atom model. In this model, any structure is dissociated into a 1st-neighbor cluster and a few glue atoms between the clusters, expressed by a cluster formula [cluster]gluex. This model is applied here to establish the structural model for eutectic liquids, assuming that a eutectic liquid consist of two subunits issued from the relevant eutectic phases, each being expressed by the cluster formula for ideal metallic glasses, i.e., [cluster](glue atom)1 or 3. A structural unit is then composed of two clusters from the relevant eutectic phases plus 2, 4, or 6 glue atoms. Such a dual cluster formulism is well validated in all boron-containing (except those located by the extreme phase diagram ends) and in some commonly-encountered binary eutectics, within accuracies below 1 at.%. The dual cluster formulas vary extensively and are rarely identical even for eutectics of close compositions. They are generally formed with two distinctly different cluster types, with special cluster matching rules such as cuboctahedron plus capped trigonal prism and rhombidodecahedron plus octahedral antiprism. PMID:26658618

  10. OB glue paste technique for establishing nude mouse human gastric cancer orthotopic transplantation models

    PubMed Central

    Shi, Jun; Wei, Pin-Kang; Zhang, Shen; Qin, Zhi-Feng; Li, Jun; Sun, Da-Zhi; Xiao, Yan; Yu, Zhi-Hong; Lin, Hui-Ming; Zheng, Guo-Jing; Su, Xiao-Mei; Chen, Ya-Lin; Liu, Yan-Fang; Xu, Ling

    2008-01-01

    AIM: To establish nude mouse human gastric cancer orthotopic transplantation models using OB glue paste technique. METHODS: Using OB glue paste technique, orthotopic transplantation models were established by implanting SGC-7901 and MKN-45 human gastric cancer cell strains into the gastric wall of nude mice. Biological features, growth of the implanted tumors, the success rate of transplantation and the rate of auto-metastasis of the two models were observed. RESULTS: The success rates of orthotopic transplan-tation of the two models were 94.20% and 96%. The rates of hepatic metastasis, pulmonary metastasis, peritoneal metastasis, lymphocytic metastasis and splenic metastasis were 42.13% and 94.20%, 48.43% and 57.97%, 30.83% and 36.96%, 67.30% and 84.06%, and 59.75% and 10.53%, respectively. The occurrence of ascites was 47.80% and 36.96%. CONCLUSION: OB glue paste technique is easy to follow. The biological behaviors of the nude mouse human gastric cancer orthotopic transplantation models established with this technique are similar to the natural processes of growth and metastasis of human gastric cancer, and, therefore, can be used as an ideal model for experimental research of proliferative metastasis of tumors. PMID:18720543

  11. Optimization of Performance Parameters for Large Area Silicon Photomultipliers

    NASA Astrophysics Data System (ADS)

    Janzen, Kathryn

    2008-10-01

    The goal of the GlueX experiment is to search for exotic hybrid mesons as evidence of gluonic excitations in an effort to better understand confinement. A key component of the GlueX detector is the electromagnetic barrel calorimeter (BCAL) located immediately inside a superconducting solenoid of approximately 2.5T. Because of this arrangement, traditional vacuum photomultiplier tubes (PMTs) which are affected significantly by magnetic fields cannot be used on the BCAL. The use of Silicon photomultipliers (SiPMs) as front-end detectors has been proposed. While the largest SiPMs that have been previously employed by other experiments are 1x1 mm^2, GlueX proposes to use large area SiPMs each composed of 16 - 3x3 mm^2 cells in a 4x4 array. This puts the GlueX collaboration in the unique position of driving the technology for larger area sensors. In this talk I will discuss tests done in Regina regarding performance parameters of prototype SiPM arrays delivered by SensL, a photonics research and development company based in Ireland, as well as sample 1x1 mm^2 and 3x3 mm^2 SiPMs.

  12. Construction of a Corneal Stromal Equivalent with SMILE-Derived Lenticules and Fibrin Glue

    PubMed Central

    Yin, Houfa; Qiu, Peijin; Wu, Fang; Zhang, Wei; Teng, Wenqi; Qin, Zhenwei; Li, Chao; Zhou, Jiaojie; Fang, Zhi; Tang, Qiaomei; Fu, Qiuli; Ma, Jian; Yang, Yabo

    2016-01-01

    The scarcity of corneal tissue to treat deep corneal defects and corneal perforations remains a challenge. Currently, small incision lenticule extraction (SMILE)-derived lenticules appear to be a promising alternative for the treatment of these conditions. However, the thickness and toughness of a single piece of lenticule are limited. To overcome these limitations, we constructed a corneal stromal equivalent with SMILE-derived lenticules and fibrin glue. In vitro cell culture revealed that the corneal stromal equivalent could provide a suitable scaffold for the survival and proliferation of corneal epithelial cells, which formed a continuous pluristratified epithelium with the expression of characteristic markers. Finally, anterior lamellar keratoplasty in rabbits demonstrated that the corneal stromal equivalent with decellularized lenticules and fibrin glue could repair the anterior region of the stroma, leading to re-epithelialization and recovery of both transparency and ultrastructural organization. Corneal neovascularization, graft degradation, and corneal rejection were not observed within 3 months. Taken together, the corneal stromal equivalent with SMILE-derived lenticules and fibrin glue appears to be a safe and effective alternative for the repair of damage to the anterior cornea, which may provide new avenues in the treatment of deep corneal defects or corneal perforations. PMID:27651001

  13. Construction of a Corneal Stromal Equivalent with SMILE-Derived Lenticules and Fibrin Glue.

    PubMed

    Yin, Houfa; Qiu, Peijin; Wu, Fang; Zhang, Wei; Teng, Wenqi; Qin, Zhenwei; Li, Chao; Zhou, Jiaojie; Fang, Zhi; Tang, Qiaomei; Fu, Qiuli; Ma, Jian; Yang, Yabo

    2016-09-21

    The scarcity of corneal tissue to treat deep corneal defects and corneal perforations remains a challenge. Currently, small incision lenticule extraction (SMILE)-derived lenticules appear to be a promising alternative for the treatment of these conditions. However, the thickness and toughness of a single piece of lenticule are limited. To overcome these limitations, we constructed a corneal stromal equivalent with SMILE-derived lenticules and fibrin glue. In vitro cell culture revealed that the corneal stromal equivalent could provide a suitable scaffold for the survival and proliferation of corneal epithelial cells, which formed a continuous pluristratified epithelium with the expression of characteristic markers. Finally, anterior lamellar keratoplasty in rabbits demonstrated that the corneal stromal equivalent with decellularized lenticules and fibrin glue could repair the anterior region of the stroma, leading to re-epithelialization and recovery of both transparency and ultrastructural organization. Corneal neovascularization, graft degradation, and corneal rejection were not observed within 3 months. Taken together, the corneal stromal equivalent with SMILE-derived lenticules and fibrin glue appears to be a safe and effective alternative for the repair of damage to the anterior cornea, which may provide new avenues in the treatment of deep corneal defects or corneal perforations.

  14. Mesh fixation with glue versus suture for chronic pain and recurrence in Lichtenstein inguinal hernioplasty.

    PubMed

    Sun, Ping; Cheng, Xiang; Deng, Shichang; Hu, Qinggang; Sun, Yi; Zheng, Qichang

    2017-02-07

    Chronic pain following mesh-based inguinal hernia repair is frequently reported, and has a significant impact on quality of life. Whether mesh fixation with glue can reduce chronic pain without increasing the recurrence rate is still controversial. To determine whether tissue adhesives can reduce postoperative complications, especially chronic pain, with no increase in recurrence rate, compared with sutures for mesh fixation in Lichtenstein hernia repair. We searched the following electronic databases with no language restrictions: the Cochrane Central Register of Controlled Trials (CENTRAL; issue 4, 2016) in the Cochrane Library (searched 11 May 2016), MEDLINE Ovid (1986 to 11 May 2016), Embase Ovid (1986 to 11 May 2016), Science Citation Index (Web of Science) (1986 to 11 May 2016), CBM (Chinese Biomedical Database), CNKI (China National Knowledge Infrastructure), VIP (a full-text database in China), Wanfang databases. We also checked reference lists of identified papers (included studies and relevant reviews). We included all randomised and quasi-randomised controlled trials comparing glue versus sutures for mesh fixation in Lichtenstein hernia repair. Cluster-RCTs were also eligible. Two review authors extracted data and assessed the risk of bias independently. Dichotomous outcomes were expressed as odds ratio (OR) with 95% confidence intervals (CI). Continuous outcomes were expressed as mean differences (MD) with 95% CIs. Twelve trials with a total of 1932 participants were included in this review. The overall postoperative chronic pain in the glue group was reduced by 37% (OR 0.63, 95% CI 0.44 to 0.91; 10 studies, 1418 participants, low-quality evidence) compared with the suture group. However, the results changed when we conducted subgroup analysis with regard to the type of mesh. Subgroup analysis of included studies using lightweight mesh showed the reduction of chronic pain was less profound and insignificant (OR 0.77, 95% CI 0.50 to 1.17). Subgroup analysis of included studies using heavyweight mesh resulted in a significant benefit from the fixation with glue (OR 0.38, 95% CI 0.17 to 0.82).Hernia recurrence was similar between the two groups (OR 1.44, 95% CI 0.63 to 3.28; 12 studies, 1932 participants, low-quality evidence). Fixation with glue was superior to suture regarding duration of the operation (MD -3.13, 95% CI -4.48 to -1.78; 9 studies, 1790 participants, low-quality evidence); haematoma (OR 0.52, 95% CI 0.31 to 0.86; 10 studies, 1384 participants, moderate-quality evidence); and recovery time to daily activities (MD -1.26, 95% CI -1.89 to -0.63; 3 studies, 403 participants, low-quality evidence).We also investigated adverse events. There were no significant differences between the two groups. For superficial wound infection pooled analyses showed OR 1.23, 95% CI 0.37 to 4.11; 7 studies, 763 participants (low-quality evidence); for mesh/deep infection OR 0.67, 95% CI 0.16 to 2.83; 8 studies, 1393 participants (low-quality evidence). Furthermore, we investigated seroma (a postoperative swelling caused by fluid) (OR 0.83, 95% CI 0.51 to 1.33); and persisting numbness (OR 0.81, 95% CI 0.57 to 1.14).Finally, six trials involving 1009 participants reported postoperative length of stay, resulting in non-significant difference between the two groups (MD -0.12, 95% CI: -0.35 to 0.10)Due to the lack of data, it was impossible to draw any distinction between synthetic glue and biological glue.Eight out of 12 trials showed high risk of bias in at least one of the investigated domains. Two studies were quasi-randomised controlled trials and the allocation sequence of one trial was not concealed. Nearly half of the included trials either did not provide adequate information or had high risk of bias regarding blinding processes. The risk of bias for incomplete outcome data of all the included studies varied from low to high risk of bias. Two trials did not report on some important outcomes. One study was funded by the manufacturer producing the fibrin sealant. Therefore, according to the 'Summary of findings' tables, the quality of the evidence (GRADE) for the outcomes is moderate to low. Based on the short-term results, glue may reduce postoperative chronic pain and not simultaneously increase the recurrence rate, compared with sutures for mesh fixation in Lichtenstein hernia repair. Glue may therefore be a sensible alternative to suture for mesh fixation in Lichtenstein repair. Larger trials with longer follow-up and high quality are warranted. The difference between synthetic glue and biological glue should also be assessed in the future.

  15. Electro-encephalographic disturbances due to chronic toxin abuse in young people, with special reference to glue-sniffing.

    PubMed

    Griesel, R D; Jansen, P; Richter, L M

    1990-11-03

    A study was carried out in order to document any abnormalities in the electro-encephalogram (EEG) that might appear in young adolescents who have deliberately inhaled the range of volatile substances loosely referred to as 'glue'. The EEGs of a group of 'street children' being assisted in a Johannesburg shelter were examined. The records were analysed for any clinical abnormalities and also subjected to spectral analysis in order to examine the overall characteristics of frequency, power and spatial distribution. The EEGs clearly revealed that, although at the time of the examination the subjects were ostensibly abstinent, both clinical and normative evidence of continuing brain disturbance was present. It was concluded that glue sniffing is likely to have long term electrocerebral sequelae.

  16. Implications for complex cognition from the hafting of tools with compound adhesives in the Middle Stone Age, South Africa

    PubMed Central

    Wadley, Lyn; Hodgskiss, Tamaryn; Grant, Michael

    2009-01-01

    Compound adhesives made from red ochre mixed with plant gum were used in the Middle Stone Age (MSA), South Africa. Replications reported here suggest that early artisans did not merely color their glues red; they deliberately effected physical transformations involving chemical changes from acidic to less acidic pH, dehydration of the adhesive near wood fires, and changes to mechanical workability and electrostatic forces. Some of the steps required for making compound adhesive seem impossible without multitasking and abstract thought. This ability suggests overlap between the cognitive abilities of modern people and people in the MSA. Our multidisciplinary analysis provides a new way to recognize complex cognition in the MSA without necessarily invoking the concept of symbolism. PMID:19433786

  17. High-Flow Arterio-Hepatic Venous Shunt in Hepatocellular Carcinoma: Use of Multi-Electrode Radiofrequency for Shunt Obliteration

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pua, Uei, E-mail: druei@yahoo.com

    2015-10-15

    Intra-tumoral arterio-hepatic venous shunting (AHVS) poses an impediment to transarterial chemoembolization of liver tumors. Not only does it present a potential hazard for systemic shunting and embolization, but also the altered flow dynamics may also result in poor delivery of drug/embolics to the target tumor bed. Current available techniques to overcome AVHS include arterial embolization (particles, coils, glue, etc.) or temporary venous occlusion using balloons. We hereby illustrate the use of radiofrequency ablation to obliterate a complex AHVS consisting of a varix-like venous aneurysm.

  18. Effect of channel coupling on the elastic scattering of lithium isotopes

    NASA Astrophysics Data System (ADS)

    Furumoto, T.; Suhara, T.; Itagaki, N.

    2018-04-01

    Herein, we investigated the channel coupling (CC) effect on the elastic scatterings of lithium (Li) isotopes (A =6 -9) for 12C and 28Si targets at E /A =50 -60 MeV. The wave functions of the Li isotopes were obtained using the stochastic multi-configuration mixing method based on the microscopic-cluster model. The proton radii of the 7Li, 8Li, and 9Li nuclei became smaller as the number of valence neutrons increased. The valence neutrons in the 8Li and 9Li nuclei exhibited a glue-like behavior, thereby attracting the α and t clusters. Based on the transition densities derived from these microscopic wave functions, the elastic-scattering cross section was calculated using a microscopic coupled-channel method with a complex G -matrix interaction. The existing experimental data for the elastic scatterings of the Li isotopes and 10Be nuclei were well reproduced. The Li isotope elastic cross sections were demonstrated for the 12C and 28Si targets at E /A =53 MeV. The glue-like effect of the valence neutrons on the Li isotope was clearly demonstrated by the CC effect on elastic scattering. Finally, we realize that the valence neutrons stabilized the bindings of the core parts and the CC effect related to core excitation was indeed reduced.

  19. Effects of adhesive dressings on stratum corneum conductance.

    PubMed

    Cavallini, Maurizio; Gazzola, Riccardo; Vaienti, Luca

    2012-05-01

    Stratum corneum is a fundamental layer of epidermis. It acts as a barrier, with antimicrobial features, regulating skin permeability and integrity as well. Adhesive dressings and their removal could alter this layer, affecting cutaneous water balance and lipid composition of stratum corneum. These changes could be monitored by measurement of cutaneous hydration. Ninety-two patients affected by wounds dressed with adhesive tapes or plasters have been studied. Measurement of skin conductance under tape/plaster and in the surrounding healthy skin, immediately after removal of dressing has been performed. Dressing age, wound localization, and characteristics were also considered. Adhesive dressings alter significantly stratum corneum conductance. Although healthy skin hydration has significant variations throughout the body, cutaneous conductance under adhesive dressing in different areas displays no significative changes. Moreover, the increase in hydration due to adhesive tapes/plasters showed no association with wound dehiscence. Adhesive dressings cause a significative increase in stratum corneum conductance, acting as a barrier to apocrine secretions. Although different hydration levels have been observed in healthy skin throughout the body, no difference exists under adhesive dressing among different regions, suggesting no contraindications in their employment throughout the body. Increase in cutaneous hydration showed no correlations with wound dehiscence, thus confirming safety and practicality of these dressings. © 2011 John Wiley & Sons A/S.

  20. Plastering mortar with antibacterial and antifungal properties studied by 1H NMR relaxometry

    NASA Astrophysics Data System (ADS)

    Jumate, E.; Aciu, C.; Manea, D. L.; Moldovan, D.; Chelcea, R.; Fechete, R.

    2017-12-01

    The Plastering mortars, with good antibacterial (in particular Escherichia coli, Staphylococcus aureus, Enterococcus faecalis, Pseudomonas aeruginosa) and antifungal (Aspergillus niger and Penicillium chrysogenum) properties, were studied by 1D NMR relaxometry and internal humidity measurements. Three recipes based on plastering mortar with variable content (0, 5 and 10 %) of Ag/ZnO nanopowders and with adequate physical characteristics regarding the mechanical strengths (CS IV), good adhesion to the substrate and low water absorption by capillarity (W2) were considered. The distributions of transverse relaxation times T2 were measured at 2 h after preparation (for mortar pasta) and then for the same samples at 2, 7, and 28 days during the hydration of mineralogical components. The T2 distributions are characterized by four components associated with hydration water and water in three types of pores of different dimension. The dimension of pores formed during hydration process are strongly dependent on the Ag/ZnO nanopowders content but finally at 28 days the pores distributions, as resulted from the T2 distributions, looks similar. Finally, the transverse relaxation ratio was linearly correlated to the compressive strength and the hydration behaviour during 132 days measured with a dedicated humidity sensor embedded inside sampled was discussed.

  1. Populations of some molds in water-damaged homes may differ if the home was constructed with gypsum drywall compared to plaster.

    PubMed

    Vesper, Stephen; Wymer, Larry; Cox, David; Dewalt, Gary

    2016-08-15

    Starting in the 1940s, gypsum drywall began replacing plaster and lathe in the U.S. home construction industry. Our goal was to evaluate whether some mold populations differ in water- damaged homes primarily constructed with gypsum drywall compared to plaster. The dust samples from the 2006 Department of Housing and Urban Development's (HUD) American Health Homes Survey (AHHS) were the subject of this analysis. The concentrations of the 36 Environmental Relative Moldiness Index (ERMI) molds were compared in homes of different ages. The homes (n=301) were built between 1878 and 2005. Homes with ERMI values >5 (n=126) were defined as water-damaged. Homes with ERMI values >5 were divided in the years 1976 to 1977 into two groups, i.e., older (n=61) and newer (n=65). Newer water-damaged homes had significantly (p=0.002) higher mean ERMI values than older water-damaged homes, 11.18 and 8.86, respectively. The Group 1 molds Aspergillus flavus, Ammophilus fumigatus, Aspergillus ochraceus, Cladosporium sphaerospermum and Trichoderma viride were found in significantly higher concentrations in newer compared to older high-ERMI homes. Some mold populations in water-damaged homes may have changed after the introduction of gypsum drywall. Published by Elsevier B.V.

  2. Science 101: Why Don't Spiders Stick to Their Own Webs?

    ERIC Educational Resources Information Center

    Robertson, Bill

    2011-01-01

    This article explains why spiders don't stick to their webs. Spiders don't get stuck in their own webs (and they aren't immune to their own glue) because they use a combination of sticky and nonsticky threads (different glands for producing those), and the glue is in droplets that the spider can avoid but the prey can't. The spider's nervous…

  3. [Embolization as a treatment method in post-traumatic right hepatic artery pseudoaneurysm].

    PubMed

    Dobrowolska-Bak, Malgorzata; Brzegowy, Paweł; Urbanik, Andrzej

    2012-01-01

    A case of 42-year-old man with post-traumatic right hepatic artery pseudoaneurysm successfully treated by endovascular embolization with histoacrylate glue is presented. Despite coils are mostly used embolic material in pseudoaneurysm, embolization with histoacrylate glue can be highly effective and quick treatment modality for post-traumatic hepatic artery pseudoaneurysm, especially in cases when it is impossible to use standard materials.

  4. Parent Versus Professional Views of the Developmental Impact of a Multi-Faceted Condition at School Age: Otitis Media with Effusion ("Glue Ear")

    ERIC Educational Resources Information Center

    Higgins, Josephine; Haggard, Mark

    2005-01-01

    Background: Several aspects of children's health and development are known from empirical studies to be associated with otitis media with effusion (OME; "glue ear"'). The "diffuse image" has been an obstacle to defining a core set of impacts about which inter-profession and parent-professional communication can be effective. Aims: The study…

  5. Acute nonlymphocytic leukemia in a glue sniffer.

    PubMed

    Caligiuri, M A; Early, A P; Marinello, M J; Preisler, H D

    1985-09-01

    A 17-year-old white male with a past history of chronic inhalational abuse of plastic glue was referred to our institution for sore throat, cervical adenopathy, and an abnormal peripheral blood smear. A diagnosis of acute myelomonocytic leukemia was made and abnormalities in cytogenetic studies were demonstrated. Specific inquiry regarding this form of drug exposure should be pursued when searching for possible etiologies of malignant disease.

  6. Transcatheter Embolization of a Large Symptomatic Pelvic Arteriovenous Malformation with Glubran 2 Acrylic Glue

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gandini, R.; Angelopoulos, G., E-mail: giorginos78@msn.com; Konda, D.

    A young patient affected by a pelvic arteriovenous malformation (pAVM) with recurrent episodes of hematuria following exercise, underwent transcatheter embolization using Glubran 2 acrylic glue (GEM, Viareggio, Italy). All branches of the pAVM were successfully occluded. The patient showed prompt resolution of symptoms and persistent occlusion of the pAVM at the 6 month follow-up.

  7. Beyond Scissors and Glue: Staff Developers Guide Teachers in Piecing Together a Vertically Aligned Curriculum and in Creating a Method to Get This Job Done

    ERIC Educational Resources Information Center

    Phelps, Vickie

    2005-01-01

    Layers and layers of curricula stuffed into vinyl binders were the norm in this Texas district until teachers sat down with scissors and glue to create a vertically aligned curriculum. They then created standards-based lessons to support the curriculum and put them into a database readily accessible by all.

  8. Data Publishing Services in a Scientific Project Platform

    NASA Astrophysics Data System (ADS)

    Schroeder, Matthias; Stender, Vivien; Wächter, Joachim

    2014-05-01

    Data-intensive science lives from data. More and more interdisciplinary projects are aligned to mutually gain access to their data, models and results. In order to achieving this, an umbrella project GLUES is established in the context of the "Sustainable Land Management" (LAMA) initiative funded by the German Federal Ministry of Education and Research (BMBF). The GLUES (Global Assessment of Land Use Dynamics, Greenhouse Gas Emissions and Ecosystem Services) project supports several different regional projects of the LAMA initiative: Within the framework of GLUES a Spatial Data Infrastructure (SDI) is implemented to facilitate publishing, sharing and maintenance of distributed global and regional scientific data sets as well as model results. The GLUES SDI supports several OGC webservices like the Catalog Service Web (CSW) which enables it to harvest data from varying regional projects. One of these regional projects is SuMaRiO (Sustainable Management of River Oases along the Tarim River) which aims to support oasis management along the Tarim River (PR China) under conditions of climatic and societal changes. SuMaRiO itself is an interdisciplinary and spatially distributed project. Working groups from twelve German institutes and universities are collecting data and driving their research in disciplines like Hydrology, Remote Sensing, and Agricultural Sciences among others. Each working group is dependent on the results of another working group. Due to the spatial distribution of participating institutes the data distribution is solved by using the eSciDoc infrastructure at the German Research Centre for Geosciences (GFZ). Further, the metadata based data exchange platform PanMetaDocs will be used by participants collaborative. PanMetaDocs supports an OAI-PMH interface which enables an Open Source metadata portal like GeoNetwork to harvest the information. The data added in PanMetaDocs can be labeled with a DOI (Digital Object Identifier) to publish the data and to harvest this information subsequently by the GLUES SDI. Our contribution will show the architecture of this new established SuMaRiO infrastructure node in a superordinate network of the GLUES infrastructure.

  9. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mandapaka, A; Ghebremedhin, A; Patyal, B

    Purpose: To validate the treatment planning system predicted proton dose beyond a heterogeneity (n-BCA glue) by making a measurement in a custom acrylic phantom. Methods: A custom cubic acrylic phantom was designed for this experiment. A container was designed to fit in the phantom. This container was filled with TRUFILL™ n-Butyl Cyanoacrylate(n-BCA) glue. When the container was placed in the phantom, its center was at a distance of 7.4cm from the entrance. This depth allows us to make measurements around the center of modulation of a 126 MeV proton beam with a 3cm spread-out-Bragg peak. To make measurements at othermore » beam energies, additional acrylic can be added in front of the phantom, to adjust the depth of the heterogeneity. A diamond detector was cross calibrated against a standard cylindrical ion chamber in a 126MeV beam. The diamond detector was then used to make dose measurements beyond the inhomogeneity. The measurement was repeated with the container filled with water. Several measurements were made at each setup, to check reproducibility of measurements. Results: For the same number of Tic3R1 counts, the dose measured with the diamond detector beyond n-BCA glue was 1.053 times the dose measured beyond the water filled container. This result is in agreement with the measured stopping power of glue (1.06). These measurements were in agreement with the dose predicted by the treatment planning system when the electron density of the heterogeneity was replaced with 1.06 before the dose calculation. Conclusion: Our initial measurements validate the dose predicted by our treatment plan in the presence of heterogeneity in a phantom. The material tested (n-BCA glue) is commonly used in the treatment of AVM’s prior to an SRS treatment. An error in dose predicted by the treatment plan in the presence of the glue can be detrimental in a single fraction high dose SRS treatment I received the n-BCA liquid embolic system samples from Codman and Shurtleff, Inc.« less

  10. Comparison of Collagen Graft Fixation Methods in the Porcine Knee: Implications for Matrix-Assisted Chondrocyte Implantation and Second-Generation Autologous Chondrocyte Implantation.

    PubMed

    Whyte, Graeme P; McGee, Alan; Jazrawi, Laith; Meislin, Robert

    2016-05-01

    To evaluate the fixation integrity at time zero of a type I/III collagen patch secured to a chondral defect in the porcine knee using methods typically employed in autologous chondrocyte implantation (ACI) and matrix-assisted chondrocyte implantation. Twenty-four porcine knee specimens underwent a medial parapatellar arthrotomy. A prefabricated template was used to create cartilage defects of 2 cm(2) in the medial femoral condyle. A size-matched collagen patch was fashioned. Four methods of fixation to the chondral defect were analyzed: group 1-saline, group 2-fibrin glue around the periphery of the patch, group 3-fibrin glue applied to the base of the defect and around the periphery of the patch, group 4-6-0 vicryl suture and fibrin glue around the periphery of the patch. Collagen patch fixation was assessed at intervals of 60, 300, 600, 900, and 1,200 cycles from full extension to 90° of flexion, performed manually without application of axial force. Patch fixation was evaluated by 2 independent observers using a customized scoring scale. Mean peripheral detachment of the patch and chondral defect uncovering remained less than 25% for all groups. Area of defect uncovering was significantly increased in group 2 compared with group 4 after 900 and 1,200 cycles (P = .0014 and P = .0025, respectively). Fibrin glue applied to the base of the defect, or suturing of the patch, reduced deformation significantly after 900 cycles. Suture increases the stability of fixation of a type I/III collagen patch to a chondral defect better than fibrin glue alone in the porcine knee after repetitive cycling, with respect to patch detachment and chondral defect uncovering. Application of fibrin glue to the base of the defect, or securing the patch with suture, decreases collagen patch deformation. In cases where minimally invasive techniques do not allow suture fixation of the collagen patch, scaffold fixation may be compromised during articular motion protocols typically used after second- and third-generation ACI procedures. Copyright © 2016 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  11. Efficiency and Safety: The Best Time to Valve a Plaster Cast.

    PubMed

    Steiner, Samuel R H; Gendi, Kirollos; Halanski, Matthew A; Noonan, Kenneth J

    2018-04-18

    The act of applying, univalving, and spreading a plaster cast to accommodate swelling is commonly performed; however, cast saws can cause thermal and/or abrasive injury to the patient. This study aims to identify the optimal time to valve a plaster cast so as to reduce the risk of cast-saw injury and increase spreading efficiency. Plaster casts were applied to life-sized pediatric models and were univalved at set-times of 5, 8, 12, or 25 minutes. Outcome measures included average and maximum force applied during univalving, blade-to-skin touches, cut time, force needed to spread, number of spread attempts, spread completeness, spread distance, saw blade temperature, and skin surface temperature. Casts allowed to set for ≥12 minutes had significantly fewer blade-to-skin touches compared with casts that set for <12 minutes (p < 0.001). For average and maximum saw blade force, no significant difference was observed between individual set-times. However, in a comparison of the shorter group (<12 minutes) and the longer group (≥12 minutes), the longer group had a higher average force (p = 0.009) but a lower maximum force (p = 0.036). The average temperature of the saw blade did not vary between groups. The maximum force needed to "pop," or spread, the cast was greater for the 5-minute and 8-minute set-times. Despite requiring more force to spread the cast, 0% of attempts at 5 minutes and 54% of attempts at 8 minutes were successful in completely spreading the cast, whereas 100% of attempts at 12 and 25 minutes were successful. The spread distance was greatest for the 12-minute set-time at 5.7 mm. Allowing casts to set for 12 minutes is associated with decreased blade-to-skin contact, less maximum force used with the saw blade, and a more effective spread. Adherence to the 12-minute interval could allow for fewer cast-saw injuries and more effective spreading.

  12. Sampling methods in archaeomagnetic dating: A comparison using case studies from Wörterberg, Eisenerz and Gams Valley (Austria)

    NASA Astrophysics Data System (ADS)

    Trapanese, A.; Batt, C. M.; Schnepp, E.

    The aim of this research was to review the relative merits of different methods of taking samples for archaeomagnetic dating. To allow different methods to be investigated, two archaeological structures and one modern fireplace were sampled in Austria. On each structure a variety of sampling methods were used: the tube and disc techniques of Clark et al. (Clark, A.J., Tarling, D.H., Noel, M., 1988. Developments in archaeomagnetic dating in Great Britain. Journal of Archaeological Science 15, 645-667), the drill core technique, the mould plastered hand block method of Thellier, and a modification of it. All samples were oriented with a magnetic compass and sun compass, where weather conditions allowed. Approximately 12 discs, tubes, drill cores or plaster hand blocks were collected from each structure, with one mould plaster hand block being collected and cut into specimens. The natural remanent magnetisation (NRM) of the samples was measured and stepwise alternating field (AF) or thermal demagnetisation was applied. Samples were measured either in the UK or in Austria, which allowed the comparison of results between magnetometers with different sensitivity. The tubes and plastered hand block specimens showed good agreement in directional results, and the samples obtained showed good stability. The discs proved to be unreliable as both NRM and the characteristic remanent magnetisation (ChRM) distribution were very scattered. The failure of some methods may be related to the suitability of the material sampled, for example if it was disturbed before sampling, had been insufficiently heated or did not contain appropriate magnetic minerals to retain a remanent magnetisation. Caution is also recommended for laboratory procedures as the cutting of poorly consolidated specimens may disturb the material and therefore the remanent magnetisation. Criteria and guidelines were established to aid researchers in selecting the most appropriate method for a particular archaeological structure.

  13. Evaluation of the iPhone with an acrylic sleeve versus the Scoliometer for rib hump measurement in scoliosis.

    PubMed

    Izatt, Maree T; Bateman, Gary R; Adam, Clayton J

    2012-07-30

    Vertebral rotation found in structural scoliosis contributes to trunkal asymmetry which is commonly measured with a simple Scoliometer device on a patient's thorax in the forward flexed position. The new generation of mobile 'smartphones' have an integrated accelerometer, making accurate angle measurement possible, which provides a potentially useful clinical tool for assessing rib hump deformity. This study aimed to compare rib hump angle measurements performed using a Smartphone and traditional Scoliometer on a set of plaster torsos representing the range of torsional deformities seen in clinical practice. Nine observers measured the rib hump found on eight plaster torsos moulded from scoliosis patients with both a Scoliometer and an Apple iPhone on separate occasions. Each observer repeated the measurements at least a week after the original measurements, and were blinded to previous results. Intra-observer reliability and inter-observer reliability were analysed using the method of Bland and Altman and 95% confidence intervals were calculated. The Intra-Class Correlation Coefficients (ICC) were calculated for repeated measurements of each of the eight plaster torso moulds by the nine observers. Mean absolute difference between pairs of iPhone/Scoliometer measurements was 2.1 degrees, with a small (1 degrees) bias toward higher rib hump angles with the iPhone. 95% confidence intervals for intra-observer variability were +/- 1.8 degrees (Scoliometer) and +/- 3.2 degrees (iPhone). 95% confidence intervals for inter-observer variability were +/- 4.9 degrees (iPhone) and +/- 3.8 degrees (Scoliometer). The measurement errors and confidence intervals found were similar to or better than the range of previously published thoracic rib hump measurement studies. The iPhone is a clinically equivalent rib hump measurement tool to the Scoliometer in spinal deformity patients. The novel use of plaster torsos as rib hump models avoids the variables of patient fatigue and discomfort, inconsistent positioning and deformity progression using human subjects in a single or multiple measurement sessions.

  14. Evaluation of the iPhone with an acrylic sleeve versus the Scoliometer for rib hump measurement in scoliosis

    PubMed Central

    2012-01-01

    Background Vertebral rotation found in structural scoliosis contributes to trunkal asymmetry which is commonly measured with a simple Scoliometer device on a patient's thorax in the forward flexed position. The new generation of mobile 'smartphones' have an integrated accelerometer, making accurate angle measurement possible, which provides a potentially useful clinical tool for assessing rib hump deformity. This study aimed to compare rib hump angle measurements performed using a Smartphone and traditional Scoliometer on a set of plaster torsos representing the range of torsional deformities seen in clinical practice. Methods Nine observers measured the rib hump found on eight plaster torsos moulded from scoliosis patients with both a Scoliometer and an Apple iPhone on separate occasions. Each observer repeated the measurements at least a week after the original measurements, and were blinded to previous results. Intra-observer reliability and inter-observer reliability were analysed using the method of Bland and Altman and 95% confidence intervals were calculated. The Intra-Class Correlation Coefficients (ICC) were calculated for repeated measurements of each of the eight plaster torso moulds by the nine observers. Results Mean absolute difference between pairs of iPhone/Scoliometer measurements was 2.1 degrees, with a small (1 degrees) bias toward higher rib hump angles with the iPhone. 95% confidence intervals for intra-observer variability were +/- 1.8 degrees (Scoliometer) and +/- 3.2 degrees (iPhone). 95% confidence intervals for inter-observer variability were +/- 4.9 degrees (iPhone) and +/- 3.8 degrees (Scoliometer). The measurement errors and confidence intervals found were similar to or better than the range of previously published thoracic rib hump measurement studies. Conclusions The iPhone is a clinically equivalent rib hump measurement tool to the Scoliometer in spinal deformity patients. The novel use of plaster torsos as rib hump models avoids the variables of patient fatigue and discomfort, inconsistent positioning and deformity progression using human subjects in a single or multiple measurement sessions. PMID:22846346

  15. Preparation and Mechanical Properties of Pressed Straw Concrete Brick

    NASA Astrophysics Data System (ADS)

    Sumarni, S.; Wijanarko, W.

    2018-03-01

    Rice straws have been widely used as wall filler material in China, Australia, and United States, by spinning them into hays with an approximate dimension of 40 cm of height, 40cm of thickness and 60 cm of width, using a machine. Then, the hays are placed into a wall frame until they fill it completely. After that, the wall frame is covered with wire mesh and plastered. In this research, rice straws are to be used as concrete brick fillers, by pressing the straws into hays and then putting them into the concrete brick mold along with mortar. The objective of this research is to investigate the mechanical properties of concrete brick, namely: compressive strength, specific gravity, and water absorption power. This research used experimental research method. It was conducted by using concrete bricks which had 400 cm of width, 200 cm of height, and 100 cm of thickness, made from rice straws, cement, sand, and water as the test sample. The straws were each made different by their volume. The mortars used in this research were made from cement, sand, and water, with the ratio of 1:7:0.5. The concrete bricks were made by pressing straws mixed with glue into hays, and then cut by determined variations of volume. The variations of hays volume were 0 m3, 0.000625 m3, 0.00075 m3, 0.000875 m3, 0.00125 m3, 0.0015 m3, 0.00175 m3, 0.001875 m3, 0.00225 m3, and 0.002625 m3. There were 3 samples for each volumes of hays. The result shows that the straw concrete bricks reached the maximum compressive strength of 1.92 MPa, specific gravity of 1,702 kg/m3, and water absorption level of 3.9 %. Based on the provided measurements of products in the Standar Nasional Indonesia (Indonesian product standardization), the concrete bricks produced attained the prescribed standard quality.

  16. Developing a non-point source P loss indicator in R and its parameter uncertainty assessment using GLUE: a case study in northern China.

    PubMed

    Su, Jingjun; Du, Xinzhong; Li, Xuyong

    2018-05-16

    Uncertainty analysis is an important prerequisite for model application. However, the existing phosphorus (P) loss indexes or indicators were rarely evaluated. This study applied generalized likelihood uncertainty estimation (GLUE) method to assess the uncertainty of parameters and modeling outputs of a non-point source (NPS) P indicator constructed in R language. And the influences of subjective choices of likelihood formulation and acceptability threshold of GLUE on model outputs were also detected. The results indicated the following. (1) Parameters RegR 2 , RegSDR 2 , PlossDP fer , PlossDP man , DPDR, and DPR were highly sensitive to overall TP simulation and their value ranges could be reduced by GLUE. (2) Nash efficiency likelihood (L 1 ) seemed to present better ability in accentuating high likelihood value simulations than the exponential function (L 2 ) did. (3) The combined likelihood integrating the criteria of multiple outputs acted better than single likelihood in model uncertainty assessment in terms of reducing the uncertainty band widths and assuring the fitting goodness of whole model outputs. (4) A value of 0.55 appeared to be a modest choice of threshold value to balance the interests between high modeling efficiency and high bracketing efficiency. Results of this study could provide (1) an option to conduct NPS modeling under one single computer platform, (2) important references to the parameter setting for NPS model development in similar regions, (3) useful suggestions for the application of GLUE method in studies with different emphases according to research interests, and (4) important insights into the watershed P management in similar regions.

  17. Autologous plasma rich in growth factors in the prevention of severe bleeding after teeth extractions in patients with bleeding disorders: a controlled comparison with fibrin glue

    PubMed Central

    Cocero, Nadia; Pucci, Fabrizio; Messina, Maria; Pollio, Berardino; Mozzati, Marco; Bergamasco, Laura

    2015-01-01

    Background Dental extractions in haemophiliacs may cause secondary bleeding, requiring repeated surgical and haematological interventions. As a local haemostatic, fibrin glue has recognised efficacy but, as a plasma-derived product, it carries the risk of viral infections. We, therefore, compared fibrin glue with an autologous haemostatic, plasma rich in growth factors (PRGF), in a controlled trial. Material and methods One hundred and twenty patients with different blood disorders were randomised into two cohorts to undergo dental extraction procedures without hospitalisation. Prior to the extractions, patients underwent systemic haematological treatment. Complications were defined as secondary bleeding after the 7-day follow-up period or protracting after the repair procedure. Results There were 106 extractions (7 retained 3rd molars) in the group managed with fibrin glue: secondary bleeding affected 3/60 patients (5%) on the third day after extraction and necessitated additional surgery and systemic treatment (in one case the procedure had to be repeated on the 7th day). In the PRGF arm there were 98 extractions (23 retained 3rd molars): secondary bleeding affected two patients (3.3%) on the first day after extraction and was arrested with surgery without systemic treatment. Four out of the five secondary bleeds occurred in patients with haemophilia A. Concomitant diabetes or liver disease significantly increased the bleeding risk. Discussion The bleeding rates in the study and control arm prove that PRGF works as well as fibrin glue as a local haemostatic. Further assets are that PRGF has autologous origin, does not require additional systemic treatment in post-extraction repair surgery, is associated with an earlier onset of neo-angiogenesis and, overall, can reduce patients’ distress and costs to the health system. PMID:25369587

  18. Fish gelatin thin film standards for biological application of PIXE

    NASA Astrophysics Data System (ADS)

    Manuel, Jack E.; Rout, Bibhudutta; Szilasi, Szabolcs Z.; Bohara, Gyanendra; Deaton, James; Luyombya, Henry; Briski, Karen P.; Glass, Gary A.

    2014-08-01

    There exists a critical need to understand the flow and accumulation of metallic ions, both naturally occurring and those introduced to biological systems. In this paper the results of fabricating thin film elemental biological standards containing nearly any combination of trace elements in a protein matrix are presented. Because it is capable of high elemental sensitivity, particle induced X-ray emission spectrometry (PIXE) is an excellent candidate for in situ analysis of biological tissues. Additionally, the utilization of microbeam PIXE allows the determination of elemental concentrations in and around biological cells. However, obtaining elemental reference standards with the same matrix constituents as brain tissue is difficult. An excellent choice for simulating brain-like tissue is Norland® photoengraving glue which is derived from fish skin. Fish glue is water soluble, liquid at room temperature, and resistant to dilute acid. It can also be formed into a thin membrane which dries into a durable, self-supporting film. Elements of interest are introduced to the fish glue in precise volumetric additions of well quantified atomic absorption standard solutions. In this study GeoPIXE analysis package is used to quantify elements intrinsic to the fish glue as well as trace amounts of manganese added to the sample. Elastic (non-Rutherford) backscattered spectroscopy (EBS) and the 1.734 MeV proton-on-carbon 12C(p,p)12C resonance is used for a normalization scheme of the PIXE spectra to account for any discrepancies in X-ray production arising from thickness variation of the prepared standards. It is demonstrated that greater additions of the atomic absorption standard cause a viscosity reduction of the liquid fish glue resulting in thinner films but the film thickness can be monitored by using simultaneous PIXE and EBS proton data acquisition.

  19. Comparison of mechanical compressive properties of commercial and autologous fibrin glues for tissue engineering applications.

    PubMed

    Cravens, Matthew G; Behn, Anthony W; Dragoo, Jason L

    2017-11-01

    Fibrin glues are widely used in orthopedic surgery as adhesives and hemostatic agents. We evaluated the compressive properties of selected fibrin glues in order to identify which are appropriate for tissue regeneration applications subject to compression. Uniaxial unconfined compression tests were performed on fibrin gels prepared from commercial and autologous products: (1) Evicel (Ethicon), (2) Tisseel (Baxter), (3) Angel (Arthrex), and (4) ProPlaz (Biorich). Cyclic loads were applied from 0 to 30% strain for 100cycles at 0.5Hz. Following cyclic testing, specimens were subjected to ramp displacement of 1% strain per second to 80% strain. Throughout cyclic loading, Evicel and Tisseel deformed (shortened) less than Angel at all but one time point, and deformed less than ProPlaz at cycles 10 and 20. The dynamic moduli, peak stress, and strain energy were significantly greater in Tisseel than all other groups. Evicel displayed significantly greater dynamic moduli, peak stress, and strain energy than Angel and ProPlaz. Following cyclic testing, Tisseel and Evicel were significantly less deformed than Angel. No specimens exhibited gross failure during ramp loading to 80% strain. Ramp loading trends mirrored those of cyclic loading. The tested commercial glues were significantly more resistant to compression than the autologous products. The compressive properties of Tisseel were approximately twice those of Evicel. All preparations displayed moduli multiple orders of magnitude less than that of native articular cartilage. We conclude that in knee surgeries requiring fibrin glue to undergo compression of daily activity, commercial products are preferable to autologous preparations from platelet-poor plasma, though both will deform significantly. Copyright © 2017 Elsevier Ltd. All rights reserved.

  20. Comparison of self-made cryopreservative fibrin glue and commercial fibrin glue kit in pterygium surgery: 1-year follow-up.

    PubMed

    Gong, Jingwen; Fan, Jiaqi; Shen, Ting; Jiang, Jin

    2018-03-01

    To assess long-term efficacy and safety of self-made cryopreservative fibrin glue (SMC) applied in pterygium surgery. Prospective, comparative, interventional case series. Forty eyes of 40 patients with nasal primary pterygium, 24 male and 16 female, were enrolled. The patients were assigned to two groups and each contained 12 male and eight female based on the pterygium area encroaching onto the cornea. In one group, the conjunctival autograft was attached to the sclera with SMC stored for 2 months, and in the other group, commercial fibrin glue kit (CK) was applied after the pterygium was removed. All the patients were followed up postoperatively on days 1, 3, 7 and 14 then at months 1, 3, 6, 12. The main outcome measures included operating time, postoperative discomfort, recurrence rate and complications. There were no significant differences in surgery time (p = 0.713) and postoperative discomfort (day 1, 3, 7; p = 0.747, p = 0.766, p = 0.983, respectively) between the two groups. By the end of 1-year follow-up, the recurrence rate was 0% in the SMC group and 5% in the CK group (p = 1.000). There were no infections and severe visual acuity (VA) threatening complications in either group. Self-made cryopreservative fibrin glue (SMC) is as effective as standard CK for autograft fixation in pterygium surgery and it also has good safety after long-term follow-up. For its convenience and low cost, this new methods should be popularized, especially in underdeveloped area. © 2017 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  1. [Effect of different number of bone marrow mesenchymal stem cells on growth of rat dorsal root ganglia in vitro].

    PubMed

    Xu, Wenjing; Zhao, Zhe; Zhao, Bin; Wang, Yu; Peng, Jiang; Zhang, Li; Chen, Jifeng; Lu, Shibi

    2011-10-01

    Bone marrow mesenchymal stem cells (BMSCs), as replacement cells of Schwann cells, can increase the effect of peripheral nerve repair. However, it has not yet reached any agreement to add the appropriate number of seeded cells in nerve scaffold. To investigate the effect of different number of BMSCs on the growth of rat dorsal root ganglia (DRG). Three 4-week-old Sprague Dawley (SD) rats (weighing 80-100 g) were selected to isolate BMSCs, which were cultured in vitro. Three 1- to 2-day-old SD rats (weighing 4-6 g) were selected to prepare DRG. BMSCs at passage 3 were used to prepare BMSCs-fibrin glue complex. According to different number of BMSCs at passage 3 in fibrin glue, experiment was divided into group A (1 x 10(3)), group B (1 x 10(4)), group C (1 x 10(5)), and group D (0, blank control), and BMSCs were co-cultured with rat DRG. The axon length of DRG, Schwann cell migration distance, and axon area index were quantitatively evaluated by morphology, neurofilament 200, and Schwann cells S-100 immunofluorescence staining after cultured for 48 hours. Some long cell processes formed in BMSCs at 48 hours; migration of Schwann cells and axons growth from the DRG were observed, growing in every direction. BMSCs in fibrin glue had the biological activity and could effect DRG growth. The axon length of DRG and Schwann cell migration distance in groups A, B, and C were significantly greater than those in group D (P < 0.05). The axon length of DRG and Schwann cell migration distance in group C were significantly less than those in group B (P < 0.05), but there was no significant difference between group A and group C, and between group A and group B (P > 0.05). The axon area index in groups A and B was significantly greater than that in group D (P < 0.05), but there was no significant difference between group C and group D (P > 0.05); there was no significant difference in groups A, B, and C (P > 0.05). In vitro study on DRG culture experiments is an ideal objective neural model of nerve regeneration. The effect of different number of BMSCs in fibrin glue on the growth of DRG has dose-effect relationship. It can provide a theoretical basis for the appropriate choice of the BMSCs number for tissue engineered nerve.

  2. Proximity of f0(1500 ) and f0(1710 ) to the scalar glueball

    NASA Astrophysics Data System (ADS)

    Fariborz, Amir H.; Azizi, Azizollah; Asrar, Abdorreza

    2015-12-01

    Within a nonlinear chiral Lagrangian framework, the underlying mixings among quark-antiquark, four-quark and glue components of f0(1500 ) and f0(1710 ) are studied in a global picture that includes all isosinglet scalar mesons below 2 GeV. The quark components are introduced in the Lagrangian in terms of two separate nonets (a quark-antiquark nonet and a four-quark nonet) which can mix with each other and with a scalar glueball. An iterative Monte Carlo simulation is developed to study the 14 free parameters of the Lagrangian by a simultaneous fit to more than 20 experimental data and constraints on the mass spectrum, decay widths, and decay ratios of the isosinglet scalars below 2 GeV. Moreover, constraints on the mass spectrum and decay widths of isodoublet and isovector scalars below 2 GeV as well as pion-pion scattering amplitude are also taken into account. In the leading order of the model and within the overall experimental uncertainties, the ranges of variation of the model parameters are determined. This leads to a set of points in the 14-dimensional parameter space at which the overall disagreement with experiment is no larger than the overall experimental uncertainties. The insights gained in this global picture, due to the complexities of the mixings as well as the experimental uncertainties, are mainly qualitative but are relatively robust, and reveal that the lowest scalar glueball hides between f0(1500 ) and f0(1710 ) , resulting in a considerable mixing with various quark components of these two states. The overall current experimental and theoretical uncertainties do not allow us to pin down the exact glue components of isosinglet states; nevertheless it is shown that the f0(1500 ) and f0(1710 ) have the highest glue component. While this global study does not allow precision predictions for each individual state, it provides useful "family" correlations among the isosinglet states that are found insightful in probing the substructure of scalars, in general, and the isosinglets, in particular. Specifically, a close correlation between the substructure of isosinglets below and above 1 GeV is observed. It is shown that as the simulations approach the limit where the f0(500 ) and f0(980 ) become the two isosinglet members of an ideally mixed two-quark two-antiquark nonet (which is widely believed to be a good approximation), the f0(1500 ) develops a large glue component. The overall estimate of the scalar glueball mass is found to be 1.58 ±0.18 GeV .

  3. Biological Glue Application in Repair of Atrioventricular Groove Rupture: A Case Report

    PubMed Central

    Durukan, Ahmet Baris; Serter, Fatih Tanzer; Gurbuz, Hasan Alper; Tavlasoglu, Murat; Ucar, Halil Ibrahim; Yorgancioglu, Cem

    2014-01-01

    Abstract Atrioventricular groove rupture is a rare, albeit mortal, complication following mitral valve surgery. Avoidance is the best strategy but it cannot fully prevent the occurrence of this complication. Several repair techniques have been described with varying success rates; however, the rarity of the complication precludes consensus about the safest technique. Here we report two cases of posterior atrioventricular groove rupture. Both cases were diagnosed immediately after the cessation of cardiopulmonary bypass. Repair was performed successfully with a technique involving the use of biological glue. The postoperative course was uneventful for both of them. Both cases are well with normally functioning mitral prostheses; one with a follow-up time of 5.5 years and the other 10 months. We believe that the glue provides additional hemostasis and support to the repaired area. PMID:25870633

  4. A novel injectable tissue adhesive based on oxidized dextran and chitosan.

    PubMed

    Balakrishnan, Biji; Soman, Dawlee; Payanam, Umashanker; Laurent, Alexandre; Labarre, Denis; Jayakrishnan, Athipettah

    2017-04-15

    A surgical adhesive that can be used in different surgical situations with or without sutures is a surgeons' dream and yet none has been able to fulfill many such demanding requirements. It was therefore a major challenge to develop an adhesive biomaterial that stops bleeding and bond tissues well, which at the same time is non-toxic, biocompatible and yet biodegradable, economically viable and appealing to the surgeon in terms of the simplicity of application in complex surgical situations. With this aim, we developed an in situ setting adhesive based on biopolymers such as chitosan and dextran. Dextran was oxidized using periodate to generate aldehyde functions on the biopolymer and then reacted with chitosan hydrochloride. Gelation occurred instantaneously upon mixing these components and the resulting gel showed good tissue adhesive properties with negligible cytotoxicity and minimal swelling in phosphate buffered saline (PBS). Rheology analysis confirmed the gelation process by demonstrating storage modulus having value higher than loss modulus. Adhesive strength was in the range 200-400gf/cm 2 which is about 4-5 times more than that of fibrin glue at comparable setting times. The adhesive showed burst strength in the range of 400-410mm of Hg which should make the same suitable as a sealant for controlling bleeding in many surgical situations even at high blood pressure. Efficacy of the adhesive as a hemostat was demonstrated in a rabbit liver injury model. Histological features after two weeks were comparable to that of commercially available BioGlue®. The adhesive also demonstrated its efficacy as a drug delivery vehicle. The present adhesive could function without the many toxicity and biocompatibility issues associated with such products. Though there are many tissue adhesives available in market, none are free of shortcomings. The newly developed surgical adhesive is a 2-component adhesive system based on time-tested, naturally occurring polysaccharides such as chitosan and dextran which are both biocompatible and biodegradable. Simple polymer modification has been carried out on both polysaccharides so that when aqueous solutions of both are mixed, the solutions gel in less than 10s and forms an adhesive that seals a variety of incisions. The strength of the adhesive is over 5-times the strength of commercially available Fibrin glue and is more tissue compliant than BioGlue®. This adhesive biomaterial showed excellent tissue bonding, was hemostatic, biocompatible and biodegradable. The significance of this work lies on the features of the developed tissue adhesive that it stops bleeding, bond the tissues well, can act as a drug delivery vehicle and would appeal to the surgeon in terms of the simplicity of application in complex surgical situations. There is no need for special delivery systems for application of this adhesive. The two-component adhesive can be applied one over the other using syringes. There is also no need for light curing with UV or visible light and the gelation between the two components spontaneously takes place on application leading to excellent tissue bonding. Copyright © 2017 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

  5. Synthesis and Characterization of High Molecular Weight Peptide Polymers and Copolymers Containing L-Dopa Residues

    DTIC Science & Technology

    1988-07-01

    polymerize E- aminocaproic acid with DPPA for the S same period of time. Portions of each sample were then mixed together and the polymerization was...copolymers between GLUE polypeptides and poly(?c.-amino caproic acid ). Concurrent enzymatic oxidation studies with GLUE peptidesihas given some...insight into the crosslinking mechanisms which control relative reactivities of specific amino acid residues towards intramolecular or intermolecular bond

  6. Effect of dieldrin in the glue line of oak plywood panels in preventing Lyctus beetle damage

    Treesearch

    Thomas McIntyre

    1961-01-01

    For many years the lumber industry has been seeking improved methods of preventing decay and insect damage to lumber and other wood products. One relatively new approach to this problem is the addition of toxic chemicals in plywood glues to prevent infestations or restrict feeding injury by wood-boring insects. Wood products treated in this manner have been marketed in...

  7. Surgical adhesives in ophthalmology: history and current trends.

    PubMed

    Guhan, Samantha; Peng, Si-Liang; Janbatian, Hrag; Saadeh, Stephanie; Greenstein, Stephen; Al Bahrani, Faisal; Fadlallah, Ali; Yeh, Tsai-Chu; Melki, Samir A

    2018-03-26

    Tissue adhesives are gaining popularity in ophthalmology, as they could potentially reduce the complications associated with current surgical methods. An ideal tissue adhesive should have superior tensile strength, be non-toxic and anti-inflammatory, improve efficiency and be cost-effective. Both synthetic and biological glues are available. The primary synthetic glues include cyanoacrylate and the recently introduced polyethylene glycol (PEG) derivatives, while most biological glues are composed of fibrin. Cyanoacrylate has a high tensile strength, but rapidly polymerises upon contact with any fluid and has been associated with histotoxicity. Fibrin induces less toxic and inflammatory reactions, and its polymerisation time can be controlled. Tensile strength studies have shown that fibrin is not as strong as cyanoacrylate. While more research is needed, PEG variants currently appear to have the most promise. These glues are non-toxic, strong and time-effective. Through MEDLINE and internet searches, this paper presents a systematic review of the current applications of surgical adhesives to corneal, glaucoma, retinal, cataract and strabismus surgeries. Our review suggests that surgical adhesives have promise to reduce problems in current ophthalmic surgical procedures. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  8. Results after endoscopic treatment of postoperative upper gastrointestinal fistulas and leaks using combined Vicryl plug and fibrin glue.

    PubMed

    Truong, S; Böhm, G; Klinge, U; Stumpf, M; Schumpelick, V

    2004-07-01

    The incidence of clinically relevant anastomotic leaks after upper gastrointestinal surgery is approximately 4% to 20%, and the associated mortality is up to 80%. Depending on the clinical presentation, the treatment options include surgery, conservative treatment with or without external drainage or endoscopic treatment. This report presents nine cases of anastomotic leaks or fistulae after surgery for upper gastrointestinal cancers that were treated by insertion of a Vicryl plug and sealing with fibrin glue. Under sedation, all nine patients underwent endoscopic lavage of the cavity at the site of anastomotic leakage. The entrance to the cavity then was filled with Vicryl mesh and sealed off with fibrin glue. After the procedure, the patients underwent endoscopy and a water-soluble contrast study for assessment of the result. Seven of the nine patients had complete healing of the anastomotic leak or fistula after one to two endoscopic treatments. In one case, the treatment failed immediately because of a large and direct tracheoesophageal fistula. Another patient experienced recurrent intrathoracic abscesses after initial technical success. Postoperative upper gastrointestinal fistulas or anastomotic leaks can be managed successfully with little morbidity by means of endoscopic insertion of Vicryl mesh with fibrin glue, thereby avoiding repetitive major surgery and its associated risks.

  9. The diced cartilage glue graft for nasal augmentation. Morphometric evidence of longevity.

    PubMed

    Tasman, Abel-Jan; Diener, Pierre-André; Litschel, Ralph

    2013-03-01

    A grafting technique that uses diced cartilage without fascia, which improves formability while maintaining long-term stability, would be a welcome addition to the rhinoplasty armamentarium. A diced cartilage glue graft was recently introduced as the Tasman technique. The technique has been used by one of us (A.-J.T.) in 28 patients who were monitored clinically for 4 to 26 months. Sonographic morphometry of the graft was used in 10 patients with a maximum follow-up of 15 months, and 2 biopsies were obtained for histologic examination. Fashioning the diced cartilage glue graft reduced operating time compared with the diced cartilage fascia graft and allowed for a wide variety of transplant shapes and sizes, depending on the mold used. All grafts were used for augmentation of the nasal dorsum or radix and healed uneventfully. Sonographic cross-section measures of the grafts changed between 6% and –29%(median, –5%) in the early postoperative phase and 8%and –7% (median, –2%) between 3 and 15 months after insertion. Histologic examination of the graft biopsies revealed viable cartilage with signs of regeneration. The diced cartilage glue graft may become an attractive alternative to accepted methods for dorsal augmentation, the diced cartilage fascia graft in particular.

  10. Transvenous embolization of cavernous sinus dural arteriovenous fistulas using detachable coils and Glubran 2 acrylic glue via the inferior petrosal sinus approach.

    PubMed

    Li, Zheng-Ran; Jiang, Zai-Bo; Huang, Ming-Sheng; Zhu, Kang-Shun; Wang, Qing; Shan, Hong

    2010-12-01

    To describe the technique, efficacy, and safety of transvenous embolisation (TVE) of cavernous sinus arteriovenous fistulas (CSDAVFs) via the inferior petrosal sinus (IPS) with detachable coils and acrylic glue. Spontaneous unilateral CSDAVFs were confirmed by cerebral angiography in eight patients, with angiographic patency of the ipsilateral IPS in three and angiographic non-visualisation of the ipsilateral IPS in five. There were two patients with complete occlusion of the ipsilateral internal jugular vein (IJV). TVE with detachable coils and acrylic glue were performed through a femoral vein and an IPS approach. TVE viaipsilateral IPS was successfully performed in all eight patients in our group. The number of detachable coils for each patient ranged from 2 to 8 (mean, 5.0). Angiography immediately after TVE showed complete occlusion of the CSCAVFs in seven patients and nearly complete occlusion in one. Complete recovery of clinical symptoms was achieved in all eight patients. No recurrence of clinical symptoms was observed at follow-up. Transvenous embolisation via an IPS approach is a highly efficient and safe treatment for CSDAVFs. Embolisation with a combination of coils and acrylic glue may help to achieve complete occlusion of fistulas with fewer coils.

  11. Single-stage excision of localized head and neck venous malformations using preoperative glue embolization.

    PubMed

    Tieu, David D; Ghodke, Basavaraj V; Vo, Nghia J; Perkins, Jonathan A

    2013-04-01

    Describe single-stage removal of head and neck venous malformations using percutaneous embolization with n-butyl cyanoacrylate (n-BCA) glue prior to surgical resection. Case series with chart review. Tertiary-care pediatric hospital. A total of 169 venous malformations were identified between 2000 and 2012, and 102 (60.1%) were in the head and neck. Thirty-five of 102 (34.3%) were observed, 56 of 102 (54.9%) had invasive therapy, and 11 of 102 (10.8%) underwent n-BCA embolization and surgery ("GES procedure"). The median age of the glue embolization and surgery cohort was 14 years (range, 6-19), and 7 of 11 (63.6%) were female. Treated venous malformations involved the oral cavity/tongue (4/11; 36.4%) and parotid/face (7/11; 63.6%). During facial lesion excision, intraoperative facial nerve monitoring was used. All surgical sites (11/11) were closed primarily. No patient in this cohort had any posttreatment nerve deficits, dysarthria, and dysphagia or lesion persistence. Localized venous malformations can be treated with preoperative percutaneous embolization with n-BCA glue followed by surgical excision. This technique, with selective motor nerve monitoring, appears safe and allows for complete venous malformation removal with limited nerve dissection, to allow maximal tissue and functional preservation.

  12. Endoscopic treatment with fibrin glue of post-intubation tracheal laceration

    PubMed Central

    Cascone, Roberto; Di Natale, Davide; Pierdiluca, Matteo; Mastromarino, Rossella; Natale, Giovanni; De Ruberto, Emanuele; Messina, Gaetana; Vicidomini, Giovanni; Santini, Mario

    2017-01-01

    Post-intubation tracheal laceration (PITL) is a rare and potential life-threatening condition requiring prompt diagnosis and treatment. A conservative treatment is indicated in patients with laceration <2 cm in length while surgery is the treatment of choice for laceration >4 cm. For laceration between 2–4 cm, the best treatment is debate; some authors recommend surgery while others do not definitely exclude endoscopic treatment. Herein, we reported the endoscopic treatment with fibrin glue of PITL. The procedure is performed using a standard video-bronchoscopy in operating room; the patient is in spontaneous breathing and deep sedation. After identification of tracheal laceration, the fibrin glue is injected through a dedicated double lumen catheter into the lesion. After mixing both components of fibrin glue, polymerization of fibrin occurs resulting in an elastic and opaque clot that closes the lesion. The key success of the procedure is based on accurate patient selection. Patients are eligible if (I) they are clinically stable and in spontaneous respiration; (II) with a small and superficial tracheal laceration (≤4 cm in length and without oesophageal injury); (III) localized at level of the upper or middle trachea; and (IV) without clinical and/or radiological signs of mediastinal collection, of emphysema or pneumomediastinum progression, and of infection. PMID:29078663

  13. Analysis of the η(548) ->π+π-π0 and η'(958) ->π+π- η channels using a 8-9 GeV tagged photon beam for the GlueX Experiment

    NASA Astrophysics Data System (ADS)

    Beattie, Tegan; Papandreou, Zisis; Stevens, Justin; GlueX Collaboration

    2016-09-01

    The primary goal of the GlueX experiment is to conduct a definitive mapping of states in the light meson sector with an emphasis on searching for exotic hybrid mesons as evidence of gluonic excitations. The experiment, housed in the Hall-D facility at Jefferson Lab following its accelerator upgrade to 12 GeV, is now entering the physics data taking phase. The η(548) and η'(958) mesons are two of the richest unflavoured light mesons readily available at GlueX energies for studying resonances. Many other light mesons have decay channels involving the η mesons with significant branching ratios, and πη / πη' resonances are among the top contenders for possibly-accessible exotic and hybrid resonances which GlueX aims to study. As such, the ability to reconstruct pure η/η' samples and analyze their decays is of utmost importance for understanding future work on more complicated analyses. Preliminary analysis results from commissioning data will be presented. This work was supported by NSERC Grant SAPJ-326516 and Jefferson Science Associates, LLC, who operates Jefferson Lab under U.S. DOE Contract No. DE-AC05-06OR23177.

  14. An overview on autologous fibrin glue in bone tissue engineering of maxillofacial surgery

    PubMed Central

    Khodakaram-Tafti, Azizollah; Mehrabani, Davood; Shaterzadeh-Yazdi, Hanieh

    2017-01-01

    The purpose of this review is to have an overview on the applications on the autologous fibrin glue as a bone graft substitute in maxillofacial injuries and defects. A search was conducted using the databases such as Medline or PubMed and Google Scholar for articles from 1985 to 2016. The criteria were “Autograft,” “Fibrin tissue adhesive,” “Tissue engineering,” “Maxillofacial injury,” and “Regenerative medicine.” Bone tissue engineering is a new promising approach for bone defect reconstruction. In this technique, cells are combined with three-dimensional scaffolds to provide a tissue-like structure to replace lost parts of the tissue. Fibrin as a natural scaffold, because of its biocompatibility and biodegradability, and the initial stability of the grafted stem cells is introduced as an excellent scaffold for tissue engineering. It promotes cell migration, proliferation, and matrix making through acceleration in angiogenesis. Growth factors in fibrin glue can stimulate and promote tissue repair. Autologous fibrin scaffolds are excellent candidates for tissue engineering so that they can be produced faster, cheaper, and in larger quantities. In addition, they are easy to use and the probability of viral or prion transmission may be decreased. Therefore, autologous fibrin glue appears to be promising scaffold in regenerative maxillofacial surgery. PMID:28584530

  15. Development of Self Fire Retardant Melamine-Animal Glue Formaldehyde (MGF) Resin for the Manufacture of BWR Ply Board

    NASA Astrophysics Data System (ADS)

    Khatua, Pijus Kanti; Dubey, Rajib Kumar; Roymahapatra, Gourisankar; Mishra, Anjan; Shahoo, Shadhu Charan; Kalawate, Aparna

    2017-10-01

    Wood is one of the most sustainable, naturally growing materials that consist mainly of combustible organic carbon compounds. Since plywood are widely used nowadays especially in buildings, furniture and cabinets. Too often the fire behavior of ply-board may be viewed as a drawback. Amino-plastic based thermosetting resin adhesives are the important and most widely used in the plywood panel industries. The fire retardant property of wood panel products by adding animal glue as an additive in the form of MGF resin and used as substitute of melamine for manufacture of plywood. Environment concerns and higher cost of petroleum based resins have resulted in the development of technologies to replace melamine partially by biomaterials for the manufacturing of resin adhesive. Natural bio-based materials such as tannin, CNSL (cardanol), lignin, soya etc. are used as partial substitution of melamine. This article presents the development of melamine-animal glue formaldehyde resin as plywood binder. About 30 % melamine was substituted by animal glue and optimized. The different physico-mechanical and fire retardant property properties tested as per IS: 1734-1983 and IS: 5509-2000 respectively are quite satisfactory. The production of adhesive from melamine with compatible natural proteinous material is cost effective, eco-friendly and enhance the fire retardant property.

  16. Damage monitoring in historical murals by speckle interferometry

    NASA Astrophysics Data System (ADS)

    Hinsch, Klaus D.; Gulker, Gerd; Joost, Holger

    2003-11-01

    In the conservation of historical murals it is important to identify loose plaster sections that threaten to fall off. Electronic speckle interferometry in combination with acoustic excitation of the object has been employed to monitor loose areas. To avoid disadvantages of high sound irradiation of the complete building a novel directional audio-sound source based on nonlinear mixing of ultrasound has been introduced. The optical system was revised for optimum performance in the new environment. Emphasis is placed on noise suppression to increase sensitivity. Furthermore, amplitude and phase data of object response over the frequency-range inspected are employed to gain additional information on the state of the plaster or paint. Laboratory studies on sample specimen supplement field campaigns at historical sites.

  17. Adhesive complex coacervate inspired by the sandcastle worm as a sealant for fetoscopic defects

    NASA Astrophysics Data System (ADS)

    Kaur, Sarbjit

    Inspired by the Sandcastle Worm, biomimetic of the water-borne adhesive was developed by complex coacervation of the synthetic copolyelectrolytes, mimicking the chemistries of the worm glue. The developed underwater adhesive was designed for sealing fetal membranes after fetoscopic surgery in twin-to-twin transfusion syndrome (TTTS) and sealing neural tissue of a fetus in aminiotic sac for spina bifida condition. Complex coacervate with increased bond strength was created by entrapping polyethylene glycol diacrylate (PEG-dA) monomer within the cross-linked coacervate network. Maximum shear bond strength of ~ 1.2 MPa on aluminum substrates was reached. The monomer-filled coacervate had complex flow behavior, thickening at low shear rates and then thinning suddenly with a 16-fold drop in viscosity at shear rates near 6 s-1. The microscale structure of the complex coacervates resembled a three-dimensional porous network of interconnected tubules. This complex coacervate adhesive was used in vitro studies to mimic the uterine wall-fetal membrane interface using a water column with one end and sealed with human fetal membranes and poultry breast, and a defect was created with an 11 French trocar. The coacervate adhesive in conjunction with the multiphase adhesive was used to seal the defect. The sealant withstood an additional traction of 12 g for 30-60 minutes and turbulence of the water column without leakage of fluid or slippage. The adhesive is nontoxic when in direct contact with human fetal membranes in an organ culture setting. A stable complex coacervate adhesive for long-term use in TTTS and spina bifida application was developed by methacrylating the copolyelectrolytes. The methacrylated coacervate was crosslinked chemically for TTTS and by photopolymerization for spina bifida. Tunable mechanical properties of the adhesive were achieved by varying the methacrylation of the polymers. Varying the amine to phosphate (A/P) ratio in the coacervate formation generated a range of viscosities. The chemically cured complex coacervate, with sodium (meta) periodate crosslinker, was tested in pig animal studies, showing promising results. The adhesive adhered to the fetal membrane tissue, with maximum strength of 473 +/- 82 KPa on aluminum substrates. The elastic modulus increased with increasing methacrylation on both the polyphosphate and polyamine within the coacervate. Photopolymerized complex coacervate adhesive was photocured using Eosin-Y and treiethanolamine photoinitiators, using a green laser diode. Soft substrate bond strength increased with increasing PEG-dA concentration to a maximum of ~90 kPa. The crosslinked complex coacervate adhesives with PEG networks swelled less than 5% over 30 days in physiological conditions. The sterile glue was nontoxic, deliverable through a fine cannula, and stable over a long time period. Preliminary animal studies show a novel innovative method to seal fetal membrane defects in humans, in utero.

  18. Comparing Composites.

    ERIC Educational Resources Information Center

    Mathras, Michael S.

    1993-01-01

    Presents an activity that models the work of chemical engineers. Students design, fabricate, and perform mechanical tests on plaster matrix composites and compare the strength to mass ratios of several products. (PR)

  19. Synthesis and Characterization of High Molecular Weight Peptide Polymers and Copolymers Containing L-Dopa Residues

    DTIC Science & Technology

    1988-07-01

    decapeptide (GLUE-12) with blocked lysines with DPPA for 24 hours. A parallel reaction was carried out to polymerize E- aminocaproic acid with DPPA for...shear adhesive strength tests. OPPA has also been used to prepare block copolymers between GLUE polypeptides and poly(e-amino caproic acid ). Concurrent...amino acid residues towards intramolecular or intermolecular bond formation. Polypeptides with repeating amino acid sequences have also been produced

  20. Development of Aspherical Active Gratings at NSRRC

    NASA Astrophysics Data System (ADS)

    Tseng, Tse-Chuan; Wang, Duan Jen; Perng, Shen-Yaw; Chen, Chien-Te; Lin, Chia-Jui; Kuan, Chien-Kuang; Ho, His-Chou; Wang, Jeremy; Fung, H. S.; Chang, Shuo-Hung

    2007-01-01

    An active grating based on a novel optical concept with bendable polynomial surface profile to reduce the coma and defocus aberrations had been designed and proved by the prototype testing. Due to the low glass transition temperature of the glue and the difference of thermal expansion coefficient between the 17-4 steel bender and silicon, the prototype distorted from flat polished condition when thermally de-blocked the polishing pitch. To improve the thermal deformation of the active grating in the polishing process, a new invar bender and high curing temperature glue were adapted to glue a silicon substrate on the bender. After some tests and manufacturer polishing, it showed acceptable conditions. In this paper we will present the design and preliminary tests of the invar active grating. Meanwhile, the design and analysis of a new 17-4 PH steel bender to be electro-less nickel plating and mechanical ruling for a new beamline will also be discussed.

  1. Emergency reinforcement of cracked paracorporeal blood pumps.

    PubMed

    Schima, Heinrich; Reindl, Christian; Stoiber, Martin; Röthy, Wilfried; Wieselthaler, Georg

    2004-01-01

    In a patient with biventricular paracorporeal cardiac support, severe cracks in the outer pump housing occurred for unknown reasons (possibly because of the application of solvent). Pump replacement was considered but estimated to be a very high risk for this particular patient. Therefore, it was decided to glue the ventricles. Gluing was done after pilot tests in a two stage procedure: first, with a special glue that hardens under exposure to ultraviolet light and then with a two component low exothermic epoxy resin. The procedure resulted in very satisfying stability for the remainder of the bridging period, and the patient could be transplanted successfully 59 days after the event. It is concluded that a carefully selected gluing procedure (caveats: with previously tested glue, a validated procedure, and as a last resort only) may bring less risk in such rare cases of pump cracks than a pump exchange.

  2. Humidity control and hydrophilic glue coating applied to mounted protein crystals improves X-ray diffraction experiments

    PubMed Central

    Baba, Seiki; Hoshino, Takeshi; Ito, Len; Kumasaka, Takashi

    2013-01-01

    Protein crystals are fragile, and it is sometimes difficult to find conditions suitable for handling and cryocooling the crystals before conducting X-ray diffraction experiments. To overcome this issue, a protein crystal-mounting method has been developed that involves a water-soluble polymer and controlled humid air that can adjust the moisture content of a mounted crystal. By coating crystals with polymer glue and exposing them to controlled humid air, the crystals were stable at room temperature and were cryocooled under optimized humidity. Moreover, the glue-coated crystals reproducibly showed gradual transformations of their lattice constants in response to a change in humidity; thus, using this method, a series of isomorphous crystals can be prepared. This technique is valuable when working on fragile protein crystals, including membrane proteins, and will also be useful for multi-crystal data collection. PMID:23999307

  3. ``Glue" approximation for the pairing interaction in the Hubbard model with next nearest neighbor hopping

    NASA Astrophysics Data System (ADS)

    Khatami, Ehsan; Macridin, Alexandru; Jarrell, Mark

    2008-03-01

    Recently, several authors have employed the ``glue" approximation for the Cuprates in which the full pairing vertex is approximated by the spin susceptibility. We study this approximation using Quantum Monte Carlo Dynamical Cluster Approximation methods on a 2D Hubbard model. By considering a reasonable finite value for the next nearest neighbor hopping, we find that this ``glue" approximation, in the current form, does not capture the correct pairing symmetry. Here, d-wave is not the leading pairing symmetry while it is the dominant symmetry using the ``exact" QMC results. We argue that the sensitivity of this approximation to the band structure changes leads to this inconsistency and that this form of interaction may not be the appropriate description of the pairing mechanism in Cuprates. We suggest improvements to this approximation which help to capture the the essential features of the QMC data.

  4. The Research of Improving the Particleboard Glue Dosing Process Based on TRIZ Analysis

    NASA Astrophysics Data System (ADS)

    Yu, Huiling; Fan, Delin; Zhang, Yizhuo

    This research creates a design methodology by synthesizing the Theory of Inventive Problem Solving (TRIZ) and cascade control based on Smith predictor. The particleboard glue supplying and dosing system case study defines the problem and the solution using the methodology proposed in the paper. Status difference existing in the gluing dosing process of particleboard production usually causes gluing volume inaccurately. In order to solve the problem above, we applied the TRIZ technical contradiction and inventive principle to improve the key process of particleboard production. The improving method mapped inaccurate problem to TRIZ technical contradiction, the prior action proposed Smith predictor as the control algorithm in the glue dosing system. This research examines the usefulness of a TRIZ based problem-solving process designed to improve the problem-solving ability of users in addressing difficult or reoccurring problems and also testify TRIZ is practicality and validity. Several suggestions are presented on how to approach this problem.

  5. [Chemical hazards when working with solvent glues].

    PubMed

    Domański, Wojciech; Makles, Zbigniew

    2012-01-01

    Solvent glues are used in a wide variety of industries, e.g., textile, footwear and rubber. The problem of workers' exposure to solvent vapors is rarely tackled within the area of occupational safety and health in small and medium-sized enterprises. In order to assess exposure to solvents, organic solvents emitted by glues were identified in the samples of workplace air. The concentration of acetone, benzene, cyclohexane, ethylbenzene, n-hexane, methylcyclohexane, butyl acetate and toluene were determined. The obtained results evidenced the presence of cyclohexane, ethylbenzene, ethylcyclohexane, heptane, n-hexane, o-xylene, methylcyclohexane, methylcyclopentane, butyl acetate and toluene in workplace air. The concentration of those compounds in workplace air was low, usually below 0.15 of MAC. At some workstations the presence of benzene was also observed. Occupational risk was assessed at workstations where gluing took place. It showed that the risk at those workstations was medium or low.

  6. An Exploratory Study of γp -> ϕ (K+K-) ω (π+π-π0) p in the GlueX Experiment at Jefferson Lab

    NASA Astrophysics Data System (ADS)

    Banks, Christopher; Salgado, Carlos; GlueX Collaboration

    Mesons are subatomic particles that have intermediate masses between electrons and protons and manifest as quark-antiquark pairs kept together by the strong force (gluons). Quantum Chromodynamics (QCD) states the possibility for mesons manifested only as gluons (glueballs) or as quarks and gluons (hybrids). Some of those hybrid mesons could have quantum numbers that are inaccessible to conventional mesons (exotics). The GlueX detector at Jefferson Lab was built to search for exotic mesons at intermediate energies (2-3 GeV masses). The reaction γp -> ϕ (K+K-) ω (π+π-π0) p is of interest for this study. By simulating the detector and the reconstruction acceptance and efficiency, and by using expected signals and backgrounds through a detailed Monte Carlo, we have studied the possibilities of observing this reaction with the present GlueX configuration. Department of Energy (DOE).

  7. Generalized Likelihood Uncertainty Estimation (GLUE) methodology for optimization of extraction in natural products.

    PubMed

    Maulidiani; Rudiyanto; Abas, Faridah; Ismail, Intan Safinar; Lajis, Nordin H

    2018-06-01

    Optimization process is an important aspect in the natural product extractions. Herein, an alternative approach is proposed for the optimization in extraction, namely, the Generalized Likelihood Uncertainty Estimation (GLUE). The approach combines the Latin hypercube sampling, the feasible range of independent variables, the Monte Carlo simulation, and the threshold criteria of response variables. The GLUE method is tested in three different techniques including the ultrasound, the microwave, and the supercritical CO 2 assisted extractions utilizing the data from previously published reports. The study found that this method can: provide more information on the combined effects of the independent variables on the response variables in the dotty plots; deal with unlimited number of independent and response variables; consider combined multiple threshold criteria, which is subjective depending on the target of the investigation for response variables; and provide a range of values with their distribution for the optimization. Copyright © 2018 Elsevier Ltd. All rights reserved.

  8. Management of a complicated pulmonary fistula caused by lung cancer using a fibrin glue-soaked polyglycolic acid sheet covered with an intercostal muscle flap.

    PubMed

    Maniwa, Tomohiro; Kaneda, Hiroyuki; Saito, Yukihito

    2009-06-01

    Pulmonary fistulas caused by tumours are very fragile and difficult to suture directly. It is impossible to close pulmonary fistulas with tissue sealants when massive air leakage occurs in the low pressure of the respiratory tract. A 73-year-old man with a pneumothorax caused by lung cancer had suffered a persistent massive air leakage for more than one month. We used a fibrin glue-soaked polyglycolic acid (PGA) sheet for sealing the complicated fistula. In addition, the visceral pleura of the fistula was wrapped with the pedicle of an intercostal muscle (ICM) flap to prevent massive air leakage. The pneumothorax did not reappear after surgery. Thus, a fibrin glue-soaked PGA sheet covered with an ICM flap was effective for sealing an intractable air-leaking fistula caused by lung cancer.

  9. MEASUREMENT OF RADON, THORON AND THEIR PROGENY IN DIFFERENT TYPES OF DWELLING IN ALMORA DISTRICT OF KUMAUN HIMALAYAN REGION.

    PubMed

    Singh, Kuldeep; Semwal, Poonam; Pant, Preeti; Gusain, G S; Joshi, Manish; Sapra, B K; Ramola, R C

    2016-10-01

    The indoor concentrations of radon ( 222 Rn), thoron ( 220 Rn) and their daughter products were measured in the dwellings of Almora district in Kumaun Himalaya, India using pin-hole dosemeters and deposition progeny sensors. The measurements were made in the residential houses built of mud, stone with cement plaster and cemented house during winter season. Average [geometric mean (GM) values] radon and thoron concentrations for all dwellings were found to be 99.82 and 79.70 Bq m -3 , respectively, while average equilibrium equivalent radon concentration and equilibrium equivalent thoron concentration (measured for the first time for this region) were measured at 35.22 and 2.52 Bq m -3 , respectively. Radon concentration (GM values) was found to be 110.73, 97.00 and 93.85 Bq m -3 for mud houses, stone with cemented plaster houses and cemented houses, respectively. On the other hand, thoron concentration values were 87.10, 75.79 and 75.68 Bq m -3 for cemented houses, mud houses and stone with cemented plaster houses, respectively. Interpretations have been made on the basis of measured radon/thoron and progeny concentration values with respect to the difference of construction material of the dwellings. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  10. Treatment of unstable intraarticular fracture of distal radius: POP casting with external fixation.

    PubMed

    ur Rahman, Obaid; Khan, Mohammad Qadeem; Rasheed, Haroon; Ahmad, Saleem

    2012-04-01

    To compare radiological and functional outcome of external fixation and distraction with conservative Plaster of Paris (POP) cast for unstable intra-articular fractures of the distal radius. The study was conducted on 60 patients with unstable intra-articular fracture of distal radius who reported to emergency or outpatient Orthopaedic Surgery department of Benazir Bhutto Hospital, Rawalpindi, between March and August 2007. They were divided into two equal groups: Group A and Group B, treated by Plaster of Paris cast, and external fixation with distraction respectively. The functional outcome in terms of freedom from pain, range of movement, grip power and deformity, and the radiological outcome of radial length, incongruity and radio-ulnar joint position were analysed at three months follow-up using a 3-point scoring scale. In Group A, 1 (3%) patient showed excellent result, 8 (27%) patients good results, 19 (63%) patients fair results and 2 (7%) patients poor result. In Group B, 14 (47%) patients showed excellent results, 11 (37%) patients good results, 4 (13%) patients fair results and 1 (3%) patient poor result. The outcome score of the Group B patients was significantly better compared to the Group A patients (p value < 0.05). External fixation has definite advantages over conventional Plaster of Paris cast in the treatment of unstable intra-articular fractures of distal radius.

  11. Steel slag: a waste industrial by-product as an alternative sustainable green building material in construction applications--an attempt for solid waste management.

    PubMed

    Pofale, Arun D; Nadeem, Mohammed

    2012-01-01

    This investigation explores the possibility of utilizing granular slag as an alternative to fine aggregate (natural sand) in construction applications like masonry and plastering. Construction industry utilizes large volume of fine aggregate in all the applications which has resulted into shortage of good quality naturally available fine aggregate. Use of granular slag serves two fold purposes, i.e. waste utilisation as well as alternative eco-friendly green building material for construction. The investigation highlights comparative study of properties with partial and full replacement of fine aggregate (natural sand) by granular slag in cement mortar applications (masonry and plastering). For this purpose, cement mortar mix proportions from 1:3, 1:4, 1:5 & 1:6 by volume were selected for 0, 25, 50, 75 & 100% replacement levels with w/c ratios of 0.60, 0.65, 0.70 & 0.72 respectively. Based on the study results, it could be inferred that replacement of natural sand with granular slag from 25 to 75% increased the packing density of mortar which resulted into reduced w/c ratio, increased strength properties of all mortar mixes. Hence, it could be recommended that the granular slag could be effectively utilized as fine aggregate in masonry and plastering applications in place of conventional cement mortar mixes using natural sand.

  12. Axial compression behaviour of reinforced wallettes fabricated using wood-wool cement panel

    NASA Astrophysics Data System (ADS)

    Noh, M. S. Md; Kamarudin, A. F.; Mokhatar, S. N.; Jaudin, A. R.; Ahmad, Z.; Ibrahim, A.; Muhamad, A. A.

    2018-04-01

    Wood-wool cement composite panel (WWCP) is one of wood based composite material that produced in a stable panel form and suitable to be used as building wall system to replace non-ecofriendly material such as brick and other masonry element. Heavy construction material such as brick requires more manpower and consume a lot of time to build the wall panel. WWCP is a lightweight material with a density range from 300 kg/m3 to 500 kg/m3 and also capable to support an imposed load from the building. This study reported on the axial compression behaviour of prefabricated reinforced wallettes constructed with wood-wool cement panel. A total of six specimens were fabricated using two layers of cross laminated WWCP bonded with normal mortar paste (Portland cement) at a mix ratio of 1:3 (cement : sand). As part of lifting mechanism, the wallettes were equipped with three steel reinforcement (T12) that embedded inside the core of wallettes. Three replicates of wallettes specimens with dimension 600 mm width and 600 mm length were fabricated without surface plaster and with 16 mm thickness of surface plaster. The wallettes were tested under axial compression load after 28 days of fabrication until failure. The result indicated that, the application of surface plaster significantly increases the loading capacity about 35 % and different orientation of the panels improve the bonding strength of the wall.

  13. Biomaterials in the treatment of anal fistula: hope or hype?

    PubMed

    Scoglio, Daniele; Walker, Avery S; Fichera, Alessandro

    2014-12-01

    Anal fistula (AF) presents a chronic problem for patients and colorectal surgeons alike. Surgical treatment may result in impairment of continence and long-term risk of recurrence. Treatment options for AFs vary according to their location and complexity. The ideal approach should result in low recurrence rates and minimal impact on continence. New technical approaches involving biologically derived products such as biological mesh, fibrin glue, fistula plug, and stem cells have been applied in the treatment of AF to improve outcomes and decrease recurrence rates and the risk of fecal incontinence. In this review, we will highlight the current evidence and describe our personal experience with these novel approaches.

  14. The regulation of crystalline silica: an industry perspective.

    PubMed

    Elzea, J M

    1997-01-01

    Silica is ubiquitous in the earth's crust. It occurs in trace to large quantities in rocks and soil. Because it is so common, the regulation of silica has affected a large number of industries, including the mining industry and any industry that uses quartz in the manufacture of a products. Mineral commodities that contain silica include diatomite, bentonite, kaolinite, talc, pyrophyllite, sand and gravel, perlite, pumice, dimension stone, and barite. Products that contain minerals, many of which are associated with silica, include paint, paper, rubber, plastic, pharmaceuticals, food, cement, plaster, cat litter, potting soil, plaster board, and miscellaneous construction materials. In collaboration with some agencies and academic centers, the silica industry is supporting research to lower health risks and to improve the methods of detecting this common material.

  15. Virtual Planning of a Complex Three-Part Bimaxillary Osteotomy

    PubMed Central

    Anghinoni, Marilena Laura

    2017-01-01

    In maxillofacial surgery, every patient presents special problems requiring careful evaluation. Conventional methods to study the deformities are still reliable, but the advent of tridimensional (3D) imaging, especially computed tomography (CT) scan and laser scanning of casts, created the opportunity to better understanding the skeletal support and the soft tissue structures. Nowadays, virtual technologies are increasingly employed in maxillofacial surgery and demonstrated precision and reliability. However, in complex surgical procedures, these new technologies are still controversial. Especially in the less frequent cases of three-part maxillary surgery, the experience is limited, and scientific literature cannot give a clear support. This paper presents the case of a young patient affected by a complex long face dentofacial deformity treated by a bimaxillary surgery with three-part segmentation of the maxilla. The operator performed the surgical study completely with a virtual workflow. Pre- and postoperative CT scan and optical scanning of plaster models were collected and compared. Every postoperatory maxillary piece was superimposed with the presurgical one, and the differences were examined in a color-coded map. Only mild differences were found near the osteotomy lines, when the bony surface and the teeth demonstrated an excellent coincidence. PMID:29318057

  16. Malignant biliary obstruction complicated by ascites: Closure of the transhepatic tract with cyanoacrylate glue after placement of an endoprosthesis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cekirge, Saruhan; Akhan, Okan; Ozmen, Mustafa

    1997-05-15

    A new technique using cyanoacrylate glue is suggested for closing the transparenchymal tract following metallic endoprosthesis placement in a patient with malignant biliary obstruction complicated by ascites. With this technique, complications related to bile reflux through the transparenchymal tract would be avoided after transhepatic endoprosthesis placement in patients who have ascites. This technique would also be useful for avoiding bleeding following transhepatic portal venous puncture.

  17. The structural genes for three Drosophila glue proteins reside at a single polytene chromosome puff locus.

    PubMed Central

    Crowley, T E; Bond, M W; Meyerowitz, E M

    1983-01-01

    The polytene chromosome puff at 68C on the Drosophila melanogaster third chromosome is thought from genetic experiments to contain the structural gene for one of the secreted salivary gland glue polypeptides, sgs-3. Previous work has demonstrated that the DNA included in this puff contains sequences that are transcribed to give three different polyadenylated RNAs that are abundant in third-larval-instar salivary glands. These have been called the group II, group III, and group IV RNAs. In the experiments reported here, we used the nucleotide sequence of the DNA coding for these RNAs to predict some of the physical and chemical properties expected of their protein products, including molecular weight, amino acid composition, and amino acid sequence. Salivary gland polypeptides with molecular weights similar to those expected for the 68C RNA translation products, and with the expected degree of incorporation of different radioactive amino acids, were purified. These proteins were shown by amino acid sequencing to correspond to the protein products of the 68C RNAs. It was further shown that each of these proteins is a part of the secreted salivary gland glue: the group IV RNA codes for the previously described sgs-3, whereas the group II and III RNAs code for the newly identified glue polypeptides sgs-8 and sgs-7. Images PMID:6406838

  18. Intraoperative use of fibrin glue dyed with methylene blue in surgery for branchial cleft anomalies.

    PubMed

    Piccioni, Michela; Bottazzoli, Marco; Nassif, Nader; Stefini, Stefania; Nicolai, Piero

    2016-09-01

    We present a new method of optimizing the results of surgery for branchial cleft anomalies based on the intraoperative injection of fibrin glue combined with methylene blue dye. Retrospective single-center cohort study. The method was applied in 17 patients suffering from branchial anomalies. Six (35.29%) had a preauricular lesion; three (17.65%) had lesions derived from the first arch/pouch/groove (type I), four (23.53%) had lesions derived from the first (type II), one (5.88%) had lesions derived from the second, one (5.88%) had lesions derived from the third, and two (11.76%) had lesions derived from the fourth. The median and mean age at surgery were 10 and 10.6 years, respectively. All patients were followed by periodic clinical and ultrasonographic examination. The combination of fibrin glue with methylene blue facilitated the correct assessment of the extension of the lesions and their intraoperative manipulation. After a mean follow-up of 47.8 months, all patients were free of disease. Intraoperative injection of branchial fistulae and cysts by a mixture of fibrin glue and methylene blue is an effective, easy, and safe tool to track lesions and achieve radical resection. The technique requires a definitive validation on a large cohort with adequate stratification of patients. 4 Laryngoscope, 126:2147-2150, 2016. © 2015 The American Laryngological, Rhinological and Otological Society, Inc.

  19. Patch-test reactions to plastic and glue allergens.

    PubMed

    Kanerva, L; Jolanki, R; Alanko, K; Estlander, T

    1999-07-01

    Plastics and glues are common causes of occupational dermatoses, but only few reports have dealt with patch-test reactions caused by plastic and glue allergens. Patients exposed to plastics and remitted to an occupational dermatology clinic, were patch-tested with 50-53 plastic and glue allergens during a 6-year period. Conventional patch-test techniques were used. The most common causes of allergic patch-test reactions in 360 patients were novolac epoxy resin (5.1%), phenol formaldehyde resin (3.1%), 4-tert-butylcatechol (2.6%), phenyl glycidyl ether (2.6%), diaminodiphenyl methane (2.2%), benzoyl peroxide (2.2%), hexamethylene tetramine (2.0%) and o-cresyl glycidyl ether (1.6%). The allergens that most often elicited irritant patch-test reactions were: benzoyl peroxide (9.5%), abitol alcohol (3.6%), hydroquinone (3.1%), acid-catalyzed phenol formaldehyde resin (2.5%) and toluene diisocyanate (1.9%). Twenty-six out of 53 chemicals caused no allergic reaction during the 6-year period. Plastic allergens in the standard series provoked allergic reactions with formaldehyde (5.8%), diglycidyl ether of bisphenol A (3.2%), 4-tert-butylphenol-formaldehyde-resin (1.1%), toluene sulphonamide formaldehyde-resin (1.1%) and triethylenglycol diacrylate (0.4%). Although half of the plastic chemicals gave no allergic patch-test reactions during a 6-year period, with unusual allergens this low yield needs to be accepted, because otherwise rare allergies will not be detected. Also a negative reaction has diagnostic value.

  20. Percutaneous sclerotherapy of massive macrocystic lymphatic malformations of the face and neck using fibrin glue with OK-432 and bleomycin.

    PubMed

    Chen, W-l; Huang, Z-q; Chai, Q; Zhang, D-m; Wang, Y-y; Wang, H-j; Wang, L; Fan, S

    2011-06-01

    Picibanil (OK-432) and bleomycin have been used as alternative sclerosing agents for lymphatic malformations. This study evaluated the clinical curative effect of sclerotherapy using fibrin glue combined with OK-432 and bleomycin for the treatment of macrocystic lymphatic malformations of the face and neck. Fifteen paediatric patients (6 males; 9 females, aged 13 months to 14 years) who had received percutaneous sclerotherapy for massive macrocystic lymphatic malformations of the face and neck were retrospectively reviewed. Affected regions included the neck, parotid region and parapharynx, mouth floor, face and cheek, and orbital regions. All patients showed preoperative symptoms of space-occupying lesions between 4 cm × 5 cm and 12 cm × 16 cm in size. Fibrin glue with OK-432 and bleomycin was injected under general anaesthesia. All patients received preoperative and follow-up CT scans. Outcomes were assessed by three surgeons. All patients exhibited mid-facial swelling for 3-4 weeks after surgery, but no major complications. Follow-up periods ranged from 8 to 16 months. Eight lesions were completely involuted, five were mostly involuted, and two were partially involuted. Percutaneous sclerotherapy using fibrin glue with OK-432 and bleomycin provided a simple, safe, and reliable alternative treatment for massive macrocystic lymphatic malformations of the face and neck. Copyright © 2011 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  1. Glue septal ablation: A promising alternative to alcohol septal ablation

    PubMed Central

    Aytemir, Kudret; Oto, Ali

    2016-01-01

    Hypertrophic cardiomyopathy (HCM) is defined as myocardial hypertrophy in the absence of another cardiac or systemic disease capable of producing the magnitude of present hypertrophy. In about 70% of patients with HCM, there is left ventricular outflow tract (LVOT) obstruction (LVOTO) and this is known as obstructive type of hypertrophic cardiomyopathy (HOCM). Cases refractory to medical treatment have had two options either surgical septal myectomy or alcohol septal ablation (ASA) to alleviate LVOT gradient. ASA may cause some life-threatening complications including conduction disturbances and complete heart block, hemodynamic compromise, ventricular arrhythmias, distant and massive myocardial necrosis. Glue septal ablation (GSA) is a promising technique for the treatment of HOCM. Glue seems to be superior to alcohol due to some intrinsic advantageous properties of glue such as immediate polymerization which prevents the leak into the left anterior descending coronary artery and it is particularly useful in patients with collaterals to the right coronary artery in whom alcohol ablation is contraindicated. In our experience, GSA is effective and also a safe technique without significant complications. GSA decreases LVOT gradient immediately after the procedure and this reduction persists during 12 months of follow-up. It improves New York Heart Association functional capacity and decrease interventricular septal wall thickness. Further studies are needed in order to assess the long-term efficacy and safety of this technique. PMID:27011786

  2. Sutureless amniotic membrane transplantation for partial limbal stem cell deficiency.

    PubMed

    Kheirkhah, Ahmad; Casas, Victoria; Raju, Vadrevu K; Tseng, Scheffer C G

    2008-05-01

    To evaluate the results of sutureless amniotic membrane (AM) transplantation using fibrin glue for reconstructing corneal surfaces with partial limbal stem cell deficiency (LSCD). Retrospective noncomparative interventional case series. Eleven eyes of nine patients that had LSCD with 120 degrees to almost 360 degrees of limbal involvement underwent superficial keratectomy to remove the conjunctivalized pannus followed by AM transplantation using fibrin glue. Additional sutureless AM patch (ProKera; Bio-Tissue, Inc, Miami, Florida, USA) was used in seven patients, and mitomycin C was applied on the cornea in four eyes and during fornix reconstruction in seven eyes. The surgery was repeated in three eyes for residual pannus. During a mean follow-up of 14.2 +/- 7.7 months (range, six to 26 months), all eyes maintained a smooth and stable corneal epithelial surface without recurrent erosion or persistent epithelial defect, and showed less stromal cloudiness and vascularization. Best-corrected visual acuity improved in nine eyes (81.8%). Corneal epithelialization proceeded by epithelial growth over AM (n = 4), accompanied by dissolution of AM (n = 4) or a combination of both (n = 3). No complication was noted regarding initial or repeated uses of fibrin glue. AM transplantation using fibrin glue appears to be a safe and effective method of restoring a stable corneal epithelium for cases with partial LSCD. This approach avoids the need of transplanting limbal epithelial stem cells.

  3. [Computer aided design and 3-dimensional printing for the production of custom trays of maxillary edentulous jaws based on 3-dimensional scan of primary impression].

    PubMed

    Chen, H; Zhao, T; Wang, Y; Sun, Y C

    2016-10-18

    To establish a digital method for production of custom trays for edentulous jaws using fused deposition modeling (FDM) based on three-dimensional (3D) scans of primary jaw impressions, and to quantitatively evaluate the accuracy. A red modeling compound was used to make a primary impression of a standard maxillary edentulous plaster model. The plaster model data and the primary impression tissue surface data were obtained using a 3D scanner. In the Gemomagic 2012 software, several commands were used, such as interactive drawing curves, partial filling holes, local offset, bodily offset, bodily shell, to imitate clinical procedures of drawing tray boundary, filling undercut, buffer, and generating the tray body. A standard shape of tray handle was designed and attached to the tray body and the data saved as stereolithography (STL) format. The data were imported into a computer system connected to a 3D FDM printing device, and the custom tray for the edentulous jaw model was printed layer upon layer at 0.2 mm/layer, using polylactic acid (PLA) filament, the tissue surface of the tray was then scanned with a 3D scanner. The registration functions of Geomagic 2012 was used to register the 3-dimentional surface data, and the point-cloud deviation analysis function of the Imageware 13.0 system was used to analyze the error. The CAD data of the custom tray was registered to the scan data, and the error between them was analyzed. The scanned plaster model surface was registered to the scanned impression surface and the scanned tray data to the CAD data, then the distance between the surface of plaster model and the scanned tissue surface of the custom tray was measured in Imageware 13.0. The deviation between the computer aided design data and the scanned data of the custom tray was (0.17±0.20) mm, with (0.19±0.18) mm in the primary stress-bearing area, (0.17±0.22) mm in the secondary stress-bearing area, (0.30±0.29) mm in the border seal area, (0.08±0.06) mm in the buffer area; the space between the tissue faces of the plaster model and the scanned tissue surface of custom tray was (1.98±0.40) mm, with (1.85±0.24) mm in the primary stress-bearing area, (1.86±0.26) mm in the secondary stress-bearing area, (1.77±0.36) mm in the border seal area, (2.90±0.26) mm in the buffer area. With 3D scanning, computer aided design and FDM technology, an efficient means of custom tray production was established.

  4. Presidential Green Chemistry Challenge: 2010 Designing Greener Chemicals Award

    EPA Pesticide Factsheets

    Presidential Green Chemistry Challenge 2010 award winner, Clarke, developed Natular, a plaster matrix that encapsulates the pesticide spinosad, slowly releasing it into water and effectively controlling mosquito larvae.

  5. 21 CFR 358.103 - Definitions.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... USE MISCELLANEOUS EXTERNAL DRUG PRODUCTS FOR OVER-THE-COUNTER HUMAN USE Wart Remover Drug Products... skin in a thin layer. (c) Plaster vehicle. A fabric, plastic, or other suitable backing material in...

  6. In vivo cartilage formation using chondrogenic-differentiated human adipose-derived mesenchymal stem cells mixed with fibrin glue.

    PubMed

    Jung, Sung-No; Rhie, Jong Won; Kwon, Ho; Jun, Young Joon; Seo, Je-Won; Yoo, Gyeol; Oh, Deuk Young; Ahn, Sang Tae; Woo, Jihyoun; Oh, Jieun

    2010-03-01

    Human adipose-derived mesenchymal stem cells (MSCs) were differentiated into chondrogenic MSCs, and fibrin glue was used together to explore the feasibility of whether cartilages can be generated in vivo by injecting the differentiated cells. Mesenchymal stem cells extracted from human adipose were differentiated into chondrogenic MSCs, and such differentiated cells mixed with fibrin glue were injected subcutaneously into the back of the nude mouse. In addition to visual evaluation of the tissues formed after 4, 8, and 12 weeks, hematoxylin-eosin staining, Masson trichrome staining, measurement of glycosaminoglycan concentration using dimethylmethylene blue, agreecan through reverse transcriptase-polymerase chain reaction, type II collagen, and expression of SOX-9 were verified. Moreover, the results were compared with 2 groups of controls: 1 control group that received only injection of chondrogenic-differentiated MSC and the supporting control group that received only fibrin glue injection. For the experimental group, cartilage-like tissues were formed after 4, 8, and 12 weeks. Formation of cartilage tissues was not observed in any of 4, 8, and 12 weeks of the control group. The supporting control group had only a small structure formation after 4 weeks, but the formed structure was completely decomposed by the 8th and 12th weeks. The range of staining dramatically increased with time at 4, 8, and 12 weeks in Masson trichrome staining. The concentration of glycosaminoglycan also increased with time. The increased level was statistically significant with more than 3 times more after 8 weeks compared with 4 weeks and more than 2 times more after 12 weeks compared with 8 weeks. Also, in reverse transcriptase-polymerase chain reaction at 4, 8, and 12 weeks, all results expressed a cartilage-specific gene called aggrecan, type II collagen, and SOX-9. The study verified that the chondrogenic-differentiated MSCs derived from human adipose tissues with fibrin glue can proliferate and form new cartilage. Our findings suggest that formation of cartilages in vivo is possible.

  7. 21 CFR 358.103 - Definitions.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... (nitrocellulose) in an appropriate nonaqueous solvent that leaves a transparent cohesive film when applied to the skin in a thin layer. (c) Plaster vehicle. A fabric, plastic, or other suitable backing material in...

  8. 21 CFR 358.503 - Definitions.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... film when applied to the skin in a thin layer. (c) Plaster vehicle. A fabric, plastic, or other suitable backing material in which medication is usually incorporated for topical application to the skin. ...

  9. 21 CFR 358.503 - Definitions.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... film when applied to the skin in a thin layer. (c) Plaster vehicle. A fabric, plastic, or other suitable backing material in which medication is usually incorporated for topical application to the skin. ...

  10. 21 CFR 358.503 - Definitions.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... film when applied to the skin in a thin layer. (c) Plaster vehicle. A fabric, plastic, or other suitable backing material in which medication is usually incorporated for topical application to the skin. ...

  11. 21 CFR 358.503 - Definitions.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... film when applied to the skin in a thin layer. (c) Plaster vehicle. A fabric, plastic, or other suitable backing material in which medication is usually incorporated for topical application to the skin. ...

  12. 27. Historic American Buildings Survey Albert S. Burns, Photographer September ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    27. Historic American Buildings Survey Albert S. Burns, Photographer September 30, 1935. PLASTER CORNICE - MUSIC ROOM - The Maples, 630 South Carolina Avenue Southeast, Washington, District of Columbia, DC

  13. 21 CFR 358.503 - Definitions.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... film when applied to the skin in a thin layer. (c) Plaster vehicle. A fabric, plastic, or other suitable backing material in which medication is usually incorporated for topical application to the skin. ...

  14. Dry solution to a sticky problem

    PubMed Central

    KARP, JEFFREY M.; LANGER, ROBERT

    2011-01-01

    Sticking plasters revolutionized the protection of minor wounds, but they’re not ideal for fragile skin. A material that mimics the adhesive properties of certain beetles’ feet might provide a solution. PMID:21886155

  15. Ways.

    ERIC Educational Resources Information Center

    Finnucan, Donna; And Others

    1985-01-01

    Describes an elementary art program that teaches children to use clay, a course in which middle-grade students made pottery using old plaster greenware molds, and an art class in which middle-grade students made Indian jewelry. (RM)

  16. Occupational exposures to styrene vapor in a manufacturing plant for fiber-reinforced composite wind turbine blades.

    PubMed

    Hammond, Duane; Garcia, Alberto; Feng, H Amy

    2011-07-01

    A utility-scale wind turbine blade manufacturing plant requested assistance from the National Institute for Occupational Safety and Health (NIOSH) in controlling worker exposures to styrene at a plant that produced 37 and 42 m long fiber-reinforced wind turbine blades. The plant requested NIOSH assistance because previous air sampling conducted by the company indicated concerns about peak styrene concentrations when workers entered the confined space inside of the wind turbine blade. NIOSH researchers conducted two site visits and collected personal breathing zone and area air samples while workers performed the wind turbine blade manufacturing tasks of vacuum-assisted resin transfer molding (VARTM), gelcoating, glue wiping, and installing the safety platform. All samples were collected during the course of normal employee work activities and analyzed for styrene using NIOSH Method 1501. All sampling was task based since full-shift sampling from a prior Occupational Safety and Health Administration (OSHA) compliance inspection did not show any exposures to styrene above the OSHA permissible exposure limit. During the initial NIOSH site visit, 67 personal breathing zone and 18 area air samples were collected while workers performed tasks of VARTM, gelcoating, glue wipe, and installation of a safety platform. After the initial site visit, the company made changes to the glue wipe task that eliminated the need for workers to enter the confined space inside of the wind turbine blade. During the follow-up site visit, 12 personal breathing zone and 8 area air samples were collected from workers performing the modified glue wipe task. During the initial site visit, the geometric means of the personal breathing zone styrene air samples were 1.8 p.p.m. (n = 21) for workers performing the VARTM task, 68 p.p.m. (n = 5) for workers installing a safety platform, and 340 p.p.m. (n = 14) for workers performing the glue wipe task, where n is the number of workers sampled for a given mean result. Gelcoating workers included job categories of millers, gelcoat machine operators, and gelcoaters. Geometric mean personal breathing zone styrene air samples were 150 p.p.m. (n = 6) for millers, 87 p.p.m. (n = 2) for the gelcoat machine operators, and 66 p.p.m. (n = 19) for gelcoaters. The geometric mean of the personal breathing zone styrene air samples from the glue wipe task measured during the follow-up site visit was 31 p.p.m. (n = 12). The closed molding VARTM process was very effective at controlling worker exposures to styrene. Personal breathing zone styrene air samples were reduced by an order of magnitude after changes were made to the glue wipe task. The company used chemical substitution to eliminate styrene exposure during the installation of the safety platform. Recommendations were provided to reduce styrene concentrations during gelcoating.

  17. Aerosol characterization and pulmonary responses in rats after short-term inhalation of fumes generated during resistance spot welding of galvanized steel.

    PubMed

    Antonini, James M; Afshari, Aliakbar; Meighan, Terence G; McKinney, Walter; Jackson, Mark; Schwegler-Berry, Diane; Burns, Dru A; LeBouf, Ryan F; Chen, Bean T; Shoeb, Mohammad; Zeidler-Erdely, Patti C

    2017-01-01

    Resistance spot welding is a common process to join metals in the automotive industry. Adhesives are often used as sealers to seams of metals that are joined. Anti-spatter compounds sometimes are sprayed onto metals to be welded to improve the weldability. Spot welding produces complex aerosols composed of metal and volatile compounds (VOCs) which can cause lung disease in workers. Male Sprague-Dawley rats (n = 12/treatment group) were exposed by inhalation to 25 mg/m 3 of aerosol for 4 h/day × 8 days during spot welding of galvanized zinc (Zn)-coated steel in the presence or absence of a glue or anti-spatter spray. Controls were exposed to filtered air. Particle size distribution and chemical composition of the generated aerosol were determined. At 1 and 7 days after exposure, bronchoalveolar lavage (BAL) was performed to assess lung toxicity. The generated particles mostly were in the submicron size range with a significant number of nanometer-sized particles formed. The primary metals present in the fumes were Fe (72.5%) and Zn (26.3%). The addition of the anti-spatter spray and glue did affect particle size distribution when spot welding galvanized steel, whereas they had no effect on metal composition. Multiple VOCs (e.g., methyl methacrylate, acetaldehyde, ethanol, acetone, benzene, xylene) were identified when spot welding using either the glue or the anti-spatter spray that were not present when welding alone. Markers of lung injury (BAL lactate dehydrogenase) and inflammation (total BAL cells/neutrophils and cytokines/chemokines) were significantly elevated compared to controls 1 day after exposure to the spot welding fumes. The elevated pulmonary response was transient as lung toxicity mostly returned to control values by 7 days. The VOCs or the concentrations that they were generated during the animal exposures had no measurable effect on the pulmonary responses. Inhalation of galvanized spot welding fumes caused acute lung toxicity most likely due to the short-term exposure of particles that contain Zn.

  18. A scientific approach to the characterization of the painting materials of Fra Mattia della Robbia polychrome terracotta altarpiece

    NASA Astrophysics Data System (ADS)

    Amadori, M. L.; Barcelli, S.; Casoli, A.; Mazzeo, R.; Prati, S.

    2013-12-01

    During the last restoration (2008-2011) of the polychrome terracotta altarpiece called Coronation of Virgin between Saints Rocco, Sebastian, Peter martyr and Antonio abbot, located in the collegiate church of S. Maria Assunta in Montecassiano (Macerata, Italy), scientific investigations were carried out to acquire detailed information about the painting technique. The identification of materials allowed a correct restoration. The altarpiece is almost entirely realized by Marco della Robbia (Fra Mattia), dates back to the first half of the XVI century and represents an interesting example of painted terracotta produced by using two different techniques: glazed polychrome terracotta and the "cold painting" technique. The characterization of the samples' material constituents was obtained by analysing the cross-sections and the fragments by different techniques (optical, SEM-EDS and ATR-FTIR microscopy as well as GC-MS), as the real nature of a component is often difficult to assess with one single technique. The optical microscope examination of paint cross-sections shows the presence of many layers, indicating the complexity of the paint stratigraphic morphologies. The original polychromy of della Robbia's masterpiece is constituted of cinnabar, red lake, red lead, orpiment, red ochre, lead white, lead tin yellow, green earth and raw umber. Two different types of gilding technique have been distinguished. The first one presents a glue mordant, and the second one shows an oil mordant composed by a mixture of red lead, red ochre, cinnabar and orpiment. The GC-MS analysis allowed the characterisation of linseed oil and a mixture of animal glue and egg as binding media stratigraphically located by the use of ATR-FTIR mapping microscopy. The analytical results of the painted terracotta integrated investigations show that original technique adopted is characterised by the application of pigments in an oil-binding medium directly applied on the substrates, probably treated with oil and animal glue. A large number of overpaintings above the original scheme of polychromy was found, which could be ascribed to almost three different interventions; the absence of modern pigments suggests that they could be realized long ago.

  19. Quantum-dot-sensitized solar cells fabricated by the combined process of the direct attachment of colloidal CdSe quantum dots having a ZnS glue layer and spray pyrolysis deposition.

    PubMed

    Im, Sang Hyuk; Lee, Yong Hui; Seok, Sang Il; Kim, Sung Woo; Kim, Sang-Wook

    2010-12-07

    We were able to attach CdSe quantum dots (QDs) having a ZnS inorganic glue layer directly to a mesoporous TiO(2) (mp-TiO(2)) surface by spray coating and thermal annealing. Quantum-dot-sensitized solar cells based on CdSe QDs having ZnS as the inorganic glue layer could easily transport generated charge carriers because of the intimate bonding between CdSe and mp-TiO(2). The application of spray pyrolysis deposition (SPD) to obtain additional CdSe layers improved the performance characteristics to V(oc) = 0.45 V, J(sc) = 10.7 mA/cm(2), fill factor = 35.8%, and power conversion efficiency = 1.7%. Furthermore, ZnS post-treatment improved the device performance to V(oc) = 0.57 V, J(sc) = 11.2 mA/cm(2), fill factor = 35.4%, and power conversion efficiency = 2.2%.

  20. Electrospinning of Biodegradable and Biocompatible Nanofiber Patches from Solutions of ``Green'' Materials for Plant Protection against Fungi Attack

    NASA Astrophysics Data System (ADS)

    Sett, Soumyadip; Lee, Minwook; Yarin, Alexander; Moghadam, S. M. Alavi; Meinke, Matthias; Schroeder, Wolfgang

    2015-11-01

    Biodegradable and biocompatible soy protein/petroleum-derived polymer monolithic fibers containing adhesives were electrospun on commercial rayon pads. The polymers used, PVA and PCL, are widely used in the biomedical industry, including such applications as drug delivery and scaffold manufacturing. Soy protein is an abundant waste of SoyDiesel production, and is widely used as a nutrient. The soy content in our fibers was as high as 40% w/w. Four different adhesives, including ordinary wood glue, repositionable glue and FDA-approved pressure-sensitive glue were used for electrospinning and electrospraying. The normal and shear adhesive strengths of the patches developed in this work were measured and compared. The adhesive strength was sufficient enough to withstand normal atmospheric conditions. These biodegradable and biocompatible nano-textured patches are ready to be used on prune locations without being carried away by wind and will protect plants against fungi attack at these locations, preventing diseases like Vine Decline.

Top