Evaluation of Petrifilm Lactic Acid Bacteria Plates for Counting Lactic Acid Bacteria in Food.
Kanagawa, Satomi; Ohshima, Chihiro; Takahashi, Hajime; Burenqiqige; Kikuchi, Misato; Sato, Fumina; Nakamura, Ayaka; Mohamed, Shimaa M; Kuda, Takashi; Kimura, Bon
2018-06-01
Although lactic acid bacteria (LAB) are used widely as starter cultures in the production of fermented foods, they are also responsible for food decay and deterioration. The undesirable growth of LAB in food causes spoilage, discoloration, and slime formation. Because of these adverse effects, food companies test for the presence of LAB in production areas and processed foods and consistently monitor the behavior of these bacteria. The 3M Petrifilm LAB Count Plates have recently been launched as a time-saving and simple-to-use plate designed for detecting and quantifying LAB. This study compares the abilities of Petrifilm LAB Count Plates and the de Man Rogosa Sharpe (MRS) agar medium to determine the LAB count in a variety of foods and swab samples collected from a food production area. Bacterial strains isolated from Petrifilm LAB Count Plates were identified by 16S rDNA sequence analysis to confirm the specificity of these plates for LAB. The results showed no significant difference in bacterial counts measured by using Petrifilm LAB Count Plates and MRS medium. Furthermore, all colonies growing on Petrifilm LAB Count Plates were confirmed to be LAB, while yeast colonies also formed in MRS medium. Petrifilm LAB Count Plates eliminated the plate preparation and plate inoculation steps, and the cultures could be started as soon as a diluted food sample was available. Food companies are required to establish quality controls and perform tests to check the quality of food products; the use of Petrifilm LAB Count Plates can simplify this testing process for food companies.
A THUMBNAIL HISTORY OF HETEROTROPHIC PLATE COUNT (HPC) METHODOLOGY IN THE UNITED STATES
Over the past 100 years, the method of determining the number of bacteria in water, foods or other materials has been termed variously as: bacterial plate count, total plate count, total viable plate count, aerobic plate count, standard plate cound and more recently, heterotrophi...
Rapid enumeration of viable bacteria by image analysis
NASA Technical Reports Server (NTRS)
Singh, A.; Pyle, B. H.; McFeters, G. A.
1989-01-01
A direct viable counting method for enumerating viable bacteria was modified and made compatible with image analysis. A comparison was made between viable cell counts determined by the spread plate method and direct viable counts obtained using epifluorescence microscopy either manually or by automatic image analysis. Cultures of Escherichia coli, Salmonella typhimurium, Vibrio cholerae, Yersinia enterocolitica and Pseudomonas aeruginosa were incubated at 35 degrees C in a dilute nutrient medium containing nalidixic acid. Filtered samples were stained for epifluorescence microscopy and analysed manually as well as by image analysis. Cells enlarged after incubation were considered viable. The viable cell counts determined using image analysis were higher than those obtained by either the direct manual count of viable cells or spread plate methods. The volume of sample filtered or the number of cells in the original sample did not influence the efficiency of the method. However, the optimal concentration of nalidixic acid (2.5-20 micrograms ml-1) and length of incubation (4-8 h) varied with the culture tested. The results of this study showed that under optimal conditions, the modification of the direct viable count method in combination with image analysis microscopy provided an efficient and quantitative technique for counting viable bacteria in a short time.
NASA Astrophysics Data System (ADS)
Ekawati, ER; Yusmiati, S. N. H.
2018-01-01
Blood cockle (Anadara granosa) has high level of zinc and protein, which is beneficial for therapeutic function for malnourished particularly stunting case in children. Zinc in animal foods is more absorbable than that from vegetable food. Blood cockle (Anadara granosa) is rich in nutrient and an excellent environment for the growth of microorganisms. This research aimed to identify the contamination of Salmonella sp., Vibrio sp. and total plate count bacteria on blood cockle (Anadara granosa). This was observation research with laboratory analysis. Salmonella sp. and Vibrio sp. were detected from blood cockle. Total plate count was determine of the total amount of the bacteria. Results detected from 20 samples of blood cockle showed that all samples were negative of Salmonella sp. and 1 sample positive Vibrio sp. The result of total plate count bacteria was < 5 x 105 colony/g sample.
Limberg, Brian J; Johnstone, Kevin; Filloon, Thomas; Catrenich, Carl
2016-09-01
Using United States Pharmacopeia-National Formulary (USP-NF) general method <1223> guidance, the Soleris(®) automated system and reagents (Nonfermenting Total Viable Count for bacteria and Direct Yeast and Mold for yeast and mold) were validated, using a performance equivalence approach, as an alternative to plate counting for total microbial content analysis using five representative microbes: Staphylococcus aureus, Bacillus subtilis, Pseudomonas aeruginosa, Candida albicans, and Aspergillus brasiliensis. Detection times (DTs) in the alternative automated system were linearly correlated to CFU/sample (R(2) = 0.94-0.97) with ≥70% accuracy per USP General Chapter <1223> guidance. The LOD and LOQ of the automated system were statistically similar to the traditional plate count method. This system was significantly more precise than plate counting (RSD 1.2-2.9% for DT, 7.8-40.6% for plate counts), was statistically comparable to plate counting with respect to variations in analyst, vial lots, and instruments, and was robust when variations in the operating detection thresholds (dTs; ±2 units) were used. The automated system produced accurate results, was more precise and less labor-intensive, and met or exceeded criteria for a valid alternative quantitative method, consistent with USP-NF general method <1223> guidance.
Uncertainty of quantitative microbiological methods of pharmaceutical analysis.
Gunar, O V; Sakhno, N G
2015-12-30
The total uncertainty of quantitative microbiological methods, used in pharmaceutical analysis, consists of several components. The analysis of the most important sources of the quantitative microbiological methods variability demonstrated no effect of culture media and plate-count techniques in the estimation of microbial count while the highly significant effect of other factors (type of microorganism, pharmaceutical product and individual reading and interpreting errors) was established. The most appropriate method of statistical analysis of such data was ANOVA which enabled not only the effect of individual factors to be estimated but also their interactions. Considering all the elements of uncertainty and combining them mathematically the combined relative uncertainty of the test results was estimated both for method of quantitative examination of non-sterile pharmaceuticals and microbial count technique without any product. These data did not exceed 35%, appropriated for a traditional plate count methods. Copyright © 2015 Elsevier B.V. All rights reserved.
Bowen, Michael E; Cavanaugh, Kerri L; Wolff, Kathleen; Davis, Dianne; Gregory, Rebecca P; Shintani, Ayumi; Eden, Svetlana; Wallston, Ken; Elasy, Tom; Rothman, Russell L
2016-08-01
To compare the effectiveness of different approaches to nutrition education in diabetes self-management education and support (DSME/S). We randomized 150 adults with type 2 diabetes to either certified diabetes educator (CDE)-delivered DSME/S with carbohydrate gram counting or the modified plate method versus general health education. The primary outcome was change in HbA1C over 6 months. At 6 months, HbA1C improved within the plate method [-0.83% (-1.29, -0.33), P<0.001] and carbohydrate counting [-0.63% (-1.03, -0.18), P=0.04] groups but not the control group [P=0.34]. Change in HbA1C from baseline between the control and intervention groups was not significant at 6 months (carbohydrate counting, P=0.36; modified plate method, P=0.08). In a pre-specified subgroup analysis of patients with a baseline HbA1C 7-10%, change in HbA1C from baseline improved in the carbohydrate counting [-0.86% (-1.47, -0.26), P=0.006] and plate method groups [-0.76% (-1.33, -0.19), P=0.01] compared to controls. CDE-delivered DSME/S focused on carbohydrate counting or the modified plate method improved glycemic control in patients with an initial HbA1C between 7 and 10%. Both carbohydrate counting and the modified plate method improve glycemic control as part of DSME/S. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
A Hidden Pitfall in the Preparation of Agar Media Undermines Microorganism Cultivability
Tanaka, Tomohiro; Kawasaki, Kosei; Daimon, Serina; Kitagawa, Wataru; Yamamoto, Kyosuke; Tamaki, Hideyuki; Tanaka, Michiko; Nakatsu, Cindy H.
2014-01-01
Microbiologists have been using agar growth medium for over 120 years. It revolutionized microbiology in the 1890s when microbiologists were seeking effective methods to isolate microorganisms, which led to the successful cultivation of microorganisms as single clones. But there has been a disparity between total cell counts and cultivable cell counts on plates, often referred to as the “great plate count anomaly,” that has long been a phenomenon that still remains unsolved. Here, we report that a common practice microbiologists have employed to prepare agar medium has a hidden pitfall: when phosphate was autoclaved together with agar to prepare solid growth media (PT medium), total colony counts were remarkably lower than those grown on agar plates in which phosphate and agar were separately autoclaved and mixed right before solidification (PS medium). We used a pure culture of Gemmatimonas aurantiaca T-27T and three representative sources of environmental samples, soil, sediment, and water, as inocula and compared colony counts between PT and PS agar plates. There were higher numbers of CFU on PS medium than on PT medium using G. aurantiaca or any of the environmental samples. Chemical analysis of PT agar plates suggested that hydrogen peroxide was contributing to growth inhibition. Comparison of 454 pyrosequences of the environmental samples to the isolates revealed that taxa grown on PS medium were more reflective of the original community structure than those grown on PT medium. Moreover, more hitherto-uncultivated microbes grew on PS than on PT medium. PMID:25281372
HETEROTROPHIC PLATE COUNT BACTERIA - WHAT IS THEIR SIGNIFICANCE IN DRINKING WATER?
The possible health significance of heterotrophic plate count (HPC) bacteria, also know in earlier terminology as standard plate count (SPC) bacteria, in drinking water has been debated for decades. While the literature documents the universal occurrence of HPC bacteria in soil, ...
Garza-Gisholt, Eduardo; Hemmi, Jan M; Hart, Nathan S; Collin, Shaun P
2014-01-01
Topographic maps that illustrate variations in the density of different neuronal sub-types across the retina are valuable tools for understanding the adaptive significance of retinal specialisations in different species of vertebrates. To date, such maps have been created from raw count data that have been subjected to only limited analysis (linear interpolation) and, in many cases, have been presented as iso-density contour maps with contour lines that have been smoothed 'by eye'. With the use of stereological approach to count neuronal distribution, a more rigorous approach to analysing the count data is warranted and potentially provides a more accurate representation of the neuron distribution pattern. Moreover, a formal spatial analysis of retinal topography permits a more robust comparison of topographic maps within and between species. In this paper, we present a new R-script for analysing the topography of retinal neurons and compare methods of interpolating and smoothing count data for the construction of topographic maps. We compare four methods for spatial analysis of cell count data: Akima interpolation, thin plate spline interpolation, thin plate spline smoothing and Gaussian kernel smoothing. The use of interpolation 'respects' the observed data and simply calculates the intermediate values required to create iso-density contour maps. Interpolation preserves more of the data but, consequently includes outliers, sampling errors and/or other experimental artefacts. In contrast, smoothing the data reduces the 'noise' caused by artefacts and permits a clearer representation of the dominant, 'real' distribution. This is particularly useful where cell density gradients are shallow and small variations in local density may dramatically influence the perceived spatial pattern of neuronal topography. The thin plate spline and the Gaussian kernel methods both produce similar retinal topography maps but the smoothing parameters used may affect the outcome.
Mueller, Sherry A; Anderson, James E; Kim, Byung R; Ball, James C
2009-04-01
Effective bacterial control in cooling-tower systems requires accurate and timely methods to count bacteria. Plate-count methods are difficult to implement on-site, because they are time- and labor-intensive and require sterile techniques. Several field-applicable methods (dipslides, Petrifilm, and adenosine triphosphate [ATP] bioluminescence) were compared with the plate count for two sample matrices--phosphate-buffered saline solution containing a pure culture of Pseudomonas fluorescens and cooling-tower water containing an undefined mixed bacterial culture. For the pure culture, (1) counts determined on nutrient agar and plate-count agar (PCA) media and expressed as colony-forming units (CFU) per milliliter were equivalent to those on R2A medium (p = 1.0 and p = 1.0, respectively); (2) Petrifilm counts were not significantly different from R2A plate counts (p = 0.99); (3) the dipslide counts were up to 2 log units higher than R2A plate counts, but this discrepancy was not statistically significant (p = 0.06); and (4) a discernable correlation (r2 = 0.67) existed between ATP readings and plate counts. For cooling-tower water samples (n = 62), (1) bacterial counts using R2A medium were higher (but not significant; p = 0.63) than nutrient agar and significantly higher than tryptone-glucose yeast extract (TGE; p = 0.03) and PCA (p < 0.001); (2) Petrifilm counts were significantly lower than nutrient agar or R2A (p = 0.02 and p < 0.001, respectively), but not statistically different from TGE, PCA, and dipslides (p = 0.55, p = 0.69, and p = 0.91, respectively); (3) the dipslide method yielded bacteria counts 1 to 3 log units lower than nutrient agar and R2A (p < 0.001), but was not significantly different from Petrifilm (p = 0.91), PCA (p = 1.00) or TGE (p = 0.07); (4) the differences between dipslides and the other methods became greater with a 6-day incubation time; and (5) the correlation between ATP readings and plate counts varied from system to system, was poor (r2 values ranged from < 0.01 to 0.47), and the ATP method was not sufficiently sensitive to measure counts below approximately 10(4) CFU/mL.
Han, Haihong; Li, Ning; Li, Yepeng; Fu, Ping; Yu, Dongmin; Li Zhigang; Du, Chunming; Guo, Yunchang
2015-01-01
To test the aerobic plate count examining capability of microbiology laboratories, to ensure the accuracy and comparability of quantitative bacteria examination results, and to improve the quality of monitoring. The 4 different concentration aerobic plate count piece samples were prepared and noted as I, II, III and IV. After homogeneity and stability tests, the samples were delivered to monitoring institutions. The results of I, II, III samples were logarithmic transformed, and evaluated with Z-score method using the robust average and standard deviation. The results of IV samples were evaluated as "satisfactory" when reported as < 10 CFU/piece or as "not satisfactory" otherwise. Pearson χ2 test was used to analyze the ratio results. 309 monitoring institutions, which was 99.04% of the total number, reported their results. 271 institutions reported a satisfactory result, and the satisfactory rate was 87.70%. There was no statistical difference in satisfactory rates of I, II and III samples which were 81.52%, 88.30% and 91.40% respectively. The satisfactory rate of IV samples was 93.33%. There was no statistical difference in satisfactory rates between provincial and municipal CDC. The quality control program has provided scientific data that the aerobic plate count capability of the laboratories meets the requirements of monitoring tasks.
Monitoring Microbial Numbers in Food by Density Centrifugation
Basel, Richard M.; Richter, Edward R.; Banwart, George J.
1983-01-01
Some foods contain low numbers of microbes that may be difficult to enumerate by the plate count method due to small food particles that interfere with the counting of colonies. Ludox colloidal silicon was coated with reducing agents to produce a nontoxic density material. Food homogenates were applied to a layered 10 and 80% mixture of modified Ludox and centrifuged at low speed. The top and bottom of the tube contained the food material, and the Ludox-containing portion was evaluated by conventional pour plate techniques. Plate counts of the Ludox mixture agreed with plate counts of the food homogenate alone. The absence of small food particles from pour plates resulted in a plate that was more easily read than pour plates of the homogenate alone. Modified Ludox was evaluated for its effect on bacteria at 4°C during a 24-h incubation period. No inhibition was observed. This method is applicable to food products, such as doughnuts, spices, tomato products, and meat, in which small food particles often interfere with routine plate counts or low dilution may inhibit colony formation. Inhibitory substances can be removed from spices, resulting in higher counts. Ludox is more economical than similar products, such as Percoll. Modified Ludox is easily rendered nontoxic by the addition of common laboratory reagents. In addition, the mixture is compatible with microbiological media. PMID:6303217
Andrade, N J; Bridgeman, T A; Zottola, E A
1998-07-01
Enterococcus faecium attached to stainless steel chips (100 mm2) was treated with the following sanitizers: sodium hypochlorite, peracetic acid (PA), peracetic acid plus an organic acid (PAS), quaternary ammonium, organic acid, and anionic acid. The effectiveness of sanitizer solutions on planktonic cells (not attached) was evaluated by the Association of Official Analytical Chemists (AOAC) suspension test. The number of attached cells was determined by impedance measurement and plate count method after vortexing. The decimal reduction (DR) in numbers of the E. faecium population was determined for the three methods and was analyzed by analysis of variance (P < 0.05) using Statview software. The adhered cells were more resistant (P < 0.05) than nonadherent cells. The DR averages for all of the sanitizers for 30 s of exposure were 6.4, 2.2, and 2.5 for the AOAC suspension test, plate count method after vortexing, and impedance measurement, respectively. Plate count and impedance methods showed a difference (P < 0.05) after 30 s of sanitizer exposure but not after 2 min. The impedance measurement was the best method to measure adherent cells. Impedance measurement required the development of a quadratic regression. The equation developed from 82 samples is as follows: log CFU/chip = 0.2385T2-0.96T + 9.35, r2 = 0.92, P < 0.05, T = impedance detection time in hours. This method showed that the sanitizers PAS and PA were more effective against E. faecium than the other sanitizers. At 30 s, the impedance method recovered about 25 times more cells than the plate count method after vortexing. These data suggest that impedance measurement is the method of choice when evaluating the number of bacterial cells adhered to a surface.
Patrone, Vania; Molinari, Paola; Morelli, Lorenzo
2016-11-21
Probiotics are actively used for treatment of diarrhoea, respiratory infections, and prevention of infectious gastrointestinal diseases. The efficacy of probiotics is due to strain-specific features and the number of viable cells; however, several reports of deviations from the label in the actual content of strains in probiotic products are a matter of concern. Most of the available data on quality focuses on probiotic products containing lactobacilli and/or bifidobacteria, while very few data are available on spore-forming probiotics. The present study evaluates the label claims for spore count and species identification in five commercial probiotic products marketed in India and Pakistan that claim to contain Bacillus clausii: Tufpro, Ecogro, Enterogermina, Entromax, and Ospor. Bacterial enumeration from three batches was done by microbiological plating methods by two independent operators. Species identification was done using PCR amplification and sequence analysis of the 16S rRNA gene, and determination of the total amount of species present in the products was done using PCR-denaturing gradient gel electrophoresis (PCR-DGGE) analysis followed by DNA sequencing of the excised bands. Plate count methods demonstrated poor correlations between quantitative label indications and bacteria recovered from plates for Tufpro, Ecogro, and Ospor. The 16S rRNA analysis performed on bacteria isolated from plate counts showed that only Enterogermina and Ospor contained homogenous B. clausii. PCR-DGGE analysis revealed that only Enterogermina had a homogenous B. clausii population while other products had mixed bacterial populations. In conclusion, the current analysis clearly demonstrates that of the five analysed commercial probiotics, only Enterogermina followed the label claims. Copyright © 2016 Elsevier B.V. All rights reserved.
Shigematsu, Toru; Ueno, Shigeaki; Tsuchida, Yasuharu; Hayashi, Mayumi; Okonogi, Hiroko; Masaki, Haruhiko; Fujii, Tomoyuki
2007-12-01
Bacterial counts under liquid cultivation using 96-well microplates were performed. The counts under liquid and under solid cultivation were equivalent in foods, although the counts under liquid cultivation exceeded those under solid cultivation in seawater, suggesting that some bacteria in seawater were viable but did not form detectable colonies. Phylogenetic analysis of bacteria obtained under liquid cultivation was also performed.
Detecting swift fox: Smoked-plate scent stations versus spotlighting
Daniel W. Uresk; Kieth E. Severson; Jody Javersak
2003-01-01
We compared two methods of detecting presence of swift fox: smoked-plate scent stations and spotlight counts. Tracks were counted on ten 1-mile (1.6-km) transects with bait/tracking plate stations every 0.1 mile (0.16 km). Vehicle spotlight counts were conducted on the same transects. Methods were compared with Spearman's rank order correlation. Repeated measures...
Jasper, Phillip W; James, Melva T; Hoover, Adam W; Muth, Eric R
2016-11-01
New technologies are emerging that may help individuals engage in healthier eating behaviors. One paradigm to test the efficacy of a technology is to determine its effect relative to environment cues that are known to cause individuals to overeat. The purpose of this work was to independently investigate two questions: How does the presence of a technology that provides bite count feedback alter eating behavior? and, How does the presence of a technology that provides bite count feedback paired with a goal alter eating behavior? Two studies investigated these research questions. The first study tested the effects of a large and small plate crossed with the presence or absence of a device that provided bite count feedback on intake. The second study tested the effects of a bite count goal with bite count feedback, again crossed with plate size, on intake. Both studies used a 2×2 between-subjects design. In the first study, 94 subjects (62 women aged 19.0±1.6 years with body mass index [BMI] 23.04±3.6) consumed lunch in a laboratory. The second study examined 99 subjects (56 women aged 18.5±1.5 years with BMI 22.73±2.70) under the same conditions. In both studies subjects consumed a single-course meal, using either a small or large plate. In the first study participants either wore or did not wear an automated bite counting device. In the second study all participants wore the bite counting device and were given either a low bite count goal (12 bites) or a high bite count goal (22 bites). Effect of plate size, feedback, and goal on consumption (grams) and number of bites taken were assessed using 2×2 analyses of variance. As adjunct measures, the effects of serving size, bite size (grams per bite), postmeal satiety, and satiety change were also assessed. In the first study there was a main effect of plate size on grams consumed and number of bites taken such that eating from a large plate led to greater consumption (P=0.001) and a greater number of bites (P=0.001). There was also a main effect of feedback on consumption and number of bites taken such that those who received feedback consumed less (P=0.011) and took fewer bites (P<0.001). In the second study there was a main effect of plate size on consumption such that those eating from a large plate consumed more (P=0.003) but did not take more bites. Further analysis revealed a main effect of goal on number of bites taken such that those who received the low goal took fewer bites (P<0.001) but did not consume less. Providing feedback on the number of bites taken from a wearable intake monitor can reduce overall intake during a single meal. Regarding the first research question, providing feedback significantly reduced intake in both plate size groups and reduced the overall number of bites taken. Regarding the second research question, participants were successful in eating to their goals. However, individuals in the low goal condition appeared to compensate for the restricted goal by taking larger bites, leading to comparable levels of consumption between the low and high goal groups. Hence, the interaction of technology with goals should be considered when introducing a health intervention. Copyright © 2016 Academy of Nutrition and Dietetics. Published by Elsevier Inc. All rights reserved.
A miniaturized counting technique for anaerobic bacteria.
Sharpe, A N; Pettipher, G L; Lloyd, G R
1976-12-01
A miniaturized counting technique gave results as good as the pour-plate and Most Probable Number (MPN) techniques for enumeration of clostridia spp. and anaerobic isolates from the gut. Highest counts were obtained when ascorbic acid (1%) and dithiothreitol (0.015%) were added to the reinforced clostridial medium used for counting. This minimized the effect of exposure to air before incubation. The miniature technique allowed up to 40 samples to be plated and incubated in one McIntosh-Filde's-type anaerobic jar, compared with 3 or 4 by the normal pour plate.
Garza-Gisholt, Eduardo; Hemmi, Jan M.; Hart, Nathan S.; Collin, Shaun P.
2014-01-01
Topographic maps that illustrate variations in the density of different neuronal sub-types across the retina are valuable tools for understanding the adaptive significance of retinal specialisations in different species of vertebrates. To date, such maps have been created from raw count data that have been subjected to only limited analysis (linear interpolation) and, in many cases, have been presented as iso-density contour maps with contour lines that have been smoothed ‘by eye’. With the use of stereological approach to count neuronal distribution, a more rigorous approach to analysing the count data is warranted and potentially provides a more accurate representation of the neuron distribution pattern. Moreover, a formal spatial analysis of retinal topography permits a more robust comparison of topographic maps within and between species. In this paper, we present a new R-script for analysing the topography of retinal neurons and compare methods of interpolating and smoothing count data for the construction of topographic maps. We compare four methods for spatial analysis of cell count data: Akima interpolation, thin plate spline interpolation, thin plate spline smoothing and Gaussian kernel smoothing. The use of interpolation ‘respects’ the observed data and simply calculates the intermediate values required to create iso-density contour maps. Interpolation preserves more of the data but, consequently includes outliers, sampling errors and/or other experimental artefacts. In contrast, smoothing the data reduces the ‘noise’ caused by artefacts and permits a clearer representation of the dominant, ‘real’ distribution. This is particularly useful where cell density gradients are shallow and small variations in local density may dramatically influence the perceived spatial pattern of neuronal topography. The thin plate spline and the Gaussian kernel methods both produce similar retinal topography maps but the smoothing parameters used may affect the outcome. PMID:24747568
Freitas, R; Nero, L A; Carvalho, A F
2009-07-01
Enumeration of mesophilic aerobes (MA) is the main quality and hygiene parameter for raw and pasteurized milk. High levels of these microorganisms indicate poor conditions in production, storage, and processing of milk, and also the presence of pathogens. Fifteen raw and 15 pasteurized milk samples were submitted for MA enumeration by a conventional plating method (using plate count agar) and Petrifilm Aerobic Count plates (3M, St. Paul, MN), followed by incubation according to 3 official protocols: IDF/ISO (incubation at 30 degrees C for 72 h), American Public Health Association (32 degrees C for 48 h), and Brazilian Ministry of Agriculture (36 degrees C for 48 h). The results were compared by linear regression and ANOVA. Considering the results from conventional methodology, good correlation indices and absence of significant differences between mean counts were observed, independent of type of milk sample (raw or pasteurized) and incubation conditions (IDF/ISO, American Public Health Association, or Ministry of Agriculture). Considering the results from Petrifilm Aerobic Count plates, good correlation indices and absence of significant differences were only observed for raw milk samples. The microbiota of pasteurized milk interfered negatively with the performance of Petrifilm Aerobic Count plates, probably because of the presence of microorganisms that poorly reduce the dye indicator of this system.
Automated food microbiology: potential for the hydrophobic grid-membrane filter.
Sharpe, A N; Diotte, M P; Dudas, I; Michaud, G L
1978-01-01
Bacterial counts obtained on hydrophobic grid-membrane filters were comparable to conventional plate counts for Pseudomonas aeruginosa, Escherichia coli, and Staphylococcus aureus in homogenates from a range of foods. The wide numerical operating range of the hydrophobic grid-membrane filters allowed sequential diluting to be reduced or even eliminated, making them attractive as components in automated systems of analysis. Food debris could be rinsed completely from the unincubated hydrophobic grid-membrane filter surface without affecting the subsequent count, thus eliminating the possibility of counting food particles, a common source of error in electronic counting systems. PMID:100054
Feldsine, Philip T; Leung, Stephanie C; Lienau, Andrew H; Mui, Linda A; Townsend, David E
2003-01-01
The relative efficacy of the SimPlate Total Plate Count-Color Indicator (TPC-CI) method (SimPlate 35 degrees C) was compared with the AOAC Official Method 966.23 (AOAC 35 degrees C) for enumeration of total aerobic microorganisms in foods. The SimPlate TPC-CI method, incubated at 30 degrees C (SimPlate 30 degrees C), was also compared with the International Organization for Standardization (ISO) 4833 method (ISO 30 degrees C). Six food types were analyzed: ground black pepper, flour, nut meats, frozen hamburger patties, frozen fruits, and fresh vegetables. All foods tested were naturally contaminated. Nineteen laboratories throughout North America and Europe participated in the study. Three method comparisons were conducted. In general, there was <0.3 mean log count difference in recovery among the SimPlate methods and their corresponding reference methods. Mean log counts between the 2 reference methods were also very similar. Repeatability (Sr) and reproducibility (SR) standard deviations were similar among the 3 method comparisons. The SimPlate method (35 degrees C) and the AOAC method were comparable for enumerating total aerobic microorganisms in foods. Similarly, the SimPlate method (30 degrees C) was comparable to the ISO method when samples were prepared and incubated according to the ISO method.
HETEROTROPHIC PLATE COUNT (HPC) METHODOLOGY IN THE UNITED STATES
ABSTRACT
In the United States (U.S.), the history of bacterial plate counting methods used for water can be traced largely through Standard Methods for the Examination of Water and Wastewater (Standard Methods). The bacterial count method has evolved from the original St...
Microorganisms as an Indicator of Hygiene Status Among Migrant Food Handlers in Peninsular Malaysia.
Woh, Pei Yee; Thong, Kwai Lin; Lim, Yvonne Ai Lian; Behnke, Jerzy Marian; Lewis, John Watkin; Mohd Zain, Siti Nursheena
2017-10-01
This study used microbial indicators to assess the hygiene status of 383 migrant food handlers from 3 urban cities in Peninsular Malaysia. Microbiological analysis revealed that all the hand swabs tested 99.5% positive for aerobic plate counts (mean [M] ± standard deviation [SD] = 3.57 ± 0.83 log 10 CFU [colony forming unit]), 20.8% positive for total coliform/ Escherichia coli (M ± SD = 0.30 ± 0.67 log 10 CFU), and 63.4% positive for Staphylococcus aureus (M ± SD = 1.38 ± 1.26 log 10 CFU). In addition, aerobic plate counts and Staphylococcus aureus counts exceeded the acceptable standard levels. Bacterial counts were found to be significantly associated with subjects' country of origin ( P = .019) and working responsibilities ( P = .001). Our findings indicate high probability of transmission of pathogenic bacteria from the food handlers' hands to customers during meal preparation and serving. This calls for improvements in personal hygiene and sanitation standards by the relevant health authorities among migrant food handlers.
Conventional plating methods were used to quantify heterotrophic bacteria from a drinking water distribution system. Three media, plate count agar (PCA), R2A agar and sheep blood agar (TSA-SB) were used to determine heterotrophic plate count (HPC) levels. Grab samples were collec...
Estimation method for serial dilution experiments.
Ben-David, Avishai; Davidson, Charles E
2014-12-01
Titration of microorganisms in infectious or environmental samples is a corner stone of quantitative microbiology. A simple method is presented to estimate the microbial counts obtained with the serial dilution technique for microorganisms that can grow on bacteriological media and develop into a colony. The number (concentration) of viable microbial organisms is estimated from a single dilution plate (assay) without a need for replicate plates. Our method selects the best agar plate with which to estimate the microbial counts, and takes into account the colony size and plate area that both contribute to the likelihood of miscounting the number of colonies on a plate. The estimate of the optimal count given by our method can be used to narrow the search for the best (optimal) dilution plate and saves time. The required inputs are the plate size, the microbial colony size, and the serial dilution factors. The proposed approach shows relative accuracy well within ±0.1log10 from data produced by computer simulations. The method maintains this accuracy even in the presence of dilution errors of up to 10% (for both the aliquot and diluent volumes), microbial counts between 10(4) and 10(12) colony-forming units, dilution ratios from 2 to 100, and plate size to colony size ratios between 6.25 to 200. Published by Elsevier B.V.
Park, Junghyun; Kim, Myunghee
2013-01-01
This study was performed to compare the performance of Sanita-Kun dry medium culture plate with those of traditional culture medium and Petrifilm dry medium culture plate for the enumeration of the mesophilic aerobic bacteria in milk, ice cream, ham, and codfish fillet. Mesophilic aerobic bacteria were comparatively evaluated in milk, ice cream, ham, and codfish fillet using Sanita-Kun aerobic count (SAC), Petrifilm aerobic count (PAC), and traditional plate count agar (PCA) media. According to the results, all methods showed high correlations of 0.989~1.000 and no significant differences were observed for enumerating the mesophilic aerobic bacteria in the tested food products. SAC method was easier to perform and count colonies efficiently as compared to the PCA and PAC methods. Therefore, we concluded that the SAC method offers an acceptable alternative to the PCA and PAC methods for counting the mesophilic aerobic bacteria in milk, ice cream, ham, and codfish fillet products. PMID:24551829
Conclusions on measurement uncertainty in microbiology.
Forster, Lynne I
2009-01-01
Since its first issue in 1999, testing laboratories wishing to comply with all the requirements of ISO/IEC 17025 have been collecting data for estimating uncertainty of measurement for quantitative determinations. In the microbiological field of testing, some debate has arisen as to whether uncertainty needs to be estimated for each method performed in the laboratory for each type of sample matrix tested. Queries also arise concerning the estimation of uncertainty when plate/membrane filter colony counts are below recommended method counting range limits. A selection of water samples (with low to high contamination) was tested in replicate with the associated uncertainty of measurement being estimated from the analytical results obtained. The analyses performed on the water samples included total coliforms, fecal coliforms, fecal streptococci by membrane filtration, and heterotrophic plate counts by the pour plate technique. For those samples where plate/membrane filter colony counts were > or =20, uncertainty estimates at a 95% confidence level were very similar for the methods, being estimated as 0.13, 0.14, 0.14, and 0.12, respectively. For those samples where plate/membrane filter colony counts were <20, estimated uncertainty values for each sample showed close agreement with published confidence limits established using a Poisson distribution approach.
Validation of an automated colony counting system for group A Streptococcus.
Frost, H R; Tsoi, S K; Baker, C A; Laho, D; Sanderson-Smith, M L; Steer, A C; Smeesters, P R
2016-02-08
The practice of counting bacterial colony forming units on agar plates has long been used as a method to estimate the concentration of live bacteria in culture. However, due to the laborious and potentially error prone nature of this measurement technique, an alternative method is desirable. Recent technologic advancements have facilitated the development of automated colony counting systems, which reduce errors introduced during the manual counting process and recording of information. An additional benefit is the significant reduction in time taken to analyse colony counting data. Whilst automated counting procedures have been validated for a number of microorganisms, the process has not been successful for all bacteria due to the requirement for a relatively high contrast between bacterial colonies and growth medium. The purpose of this study was to validate an automated counting system for use with group A Streptococcus (GAS). Twenty-one different GAS strains, representative of major emm-types, were selected for assessment. In order to introduce the required contrast for automated counting, 2,3,5-triphenyl-2H-tetrazolium chloride (TTC) dye was added to Todd-Hewitt broth with yeast extract (THY) agar. Growth on THY agar with TTC was compared with growth on blood agar and THY agar to ensure the dye was not detrimental to bacterial growth. Automated colony counts using a ProtoCOL 3 instrument were compared with manual counting to confirm accuracy over the stages of the growth cycle (latent, mid-log and stationary phases) and in a number of different assays. The average percentage differences between plating and counting methods were analysed using the Bland-Altman method. A percentage difference of ±10 % was determined as the cut-off for a critical difference between plating and counting methods. All strains measured had an average difference of less than 10 % when plated on THY agar with TTC. This consistency was also observed over all phases of the growth cycle and when plated in blood following bactericidal assays. Agreement between these methods suggest the use of an automated colony counting technique for GAS will significantly reduce time spent counting bacteria to enable a more efficient and accurate measurement of bacteria concentration in culture.
Garcés-Vega, Francisco; Marks, Bradley P
2014-08-01
In the last 20 years, the use of microbial reduction models has expanded significantly, including inactivation (linear and nonlinear), survival, and transfer models. However, a major constraint for model development is the impossibility to directly quantify the number of viable microorganisms below the limit of detection (LOD) for a given study. Different approaches have been used to manage this challenge, including ignoring negative plate counts, using statistical estimations, or applying data transformations. Our objective was to illustrate and quantify the effect of negative plate count data management approaches on parameter estimation for microbial reduction models. Because it is impossible to obtain accurate plate counts below the LOD, we performed simulated experiments to generate synthetic data for both log-linear and Weibull-type microbial reductions. We then applied five different, previously reported data management practices and fit log-linear and Weibull models to the resulting data. The results indicated a significant effect (α = 0.05) of the data management practices on the estimated model parameters and performance indicators. For example, when the negative plate counts were replaced by the LOD for log-linear data sets, the slope of the subsequent log-linear model was, on average, 22% smaller than for the original data, the resulting model underpredicted lethality by up to 2.0 log, and the Weibull model was erroneously selected as the most likely correct model for those data. The results demonstrate that it is important to explicitly report LODs and related data management protocols, which can significantly affect model results, interpretation, and utility. Ultimately, we recommend using only the positive plate counts to estimate model parameters for microbial reduction curves and avoiding any data value substitutions or transformations when managing negative plate counts to yield the most accurate model parameters.
Death of the Escherichia coli K-12 strain W3110 in soil and water.
Bogosian, G; Sammons, L E; Morris, P J; O'Neil, J P; Heitkamp, M A; Weber, D B
1996-01-01
Whether Escherichia coli K-12 strain W3110 can enter the "viable but nonculturable" state was studied with sterile and nonsterile water and soil at various temperatures. In nonsterile river water, the plate counts of added E. coli cells dropped to less than 10 CFU/ml in less than 10 days. Acridine orange direct counts, direct viable counts, most-probable-number estimates, and PCR analyses indicated that the added E. coli cells were disappearing from the water in parallel with the number of CFU. Similar results were obtained with nonsterile soil, although the decline of the added E. coli was slower. In sterile water or soil, the added E. coli persisted for much longer, often without any decline in the plate counts even after 50 days. In sterile river water at 37 degrees C and sterile artificial seawater at 20 and 37 degrees C, the plate counts declined by 3 to 5 orders of magnitude, while the acridine orange direct counts remained unchanged. However, direct viable counts and various resuscitation studies all indicated that the nonculturable cells were nonviable. Thus, in either sterile or nonsterile water and soil, the decline in plate counts of E. coli K-12 strain W3110 is not due to the cells entering the viable but nonculturable state, but is simply due to their death. PMID:8900002
Establishment of HPC(R2A) for regrowth control in non-chlorinated distribution systems.
Uhl, Wolfgang; Schaule, Gabriela
2004-05-01
Drinking water distributed without disinfection and without regrowth problems for many years may show bacterial regrowth when the residence time and/or temperature in the distribution system increases or when substrate and/or bacterial concentration in the treated water increases. An example of a regrowth event in a major German city is discussed. Regrowth of HPC bacteria occurred unexpectedly at the end of a very hot summer. No pathogenic or potentially pathogenic bacteria were identified. Increased residence times in the distribution system and temperatures up to 25 degrees C were identified as most probable causes and the regrowth event was successfully overcome by changing flow regimes and decreasing residence times. Standard plate counts of HPC bacteria using the spread plate technique on nutrient rich agar according to German Drinking Water Regulations (GDWR) had proven to be a very good indicator of hygienically safe drinking water and to demonstrate the effectiveness of water treatment. However, the method proved insensitive for early regrowth detection. Regrowth experiments in the lab and sampling of the distribution system during two summers showed that spread plate counts on nutrient-poor R2A agar after 7-day incubation yielded 100 to 200 times higher counts. Counts on R2A after 3-day incubation were three times less than after 7 days. As the precision of plate count methods is very poor for counts less than 10 cfu/plate, a method yielding higher counts is better suited to detect upcoming regrowth than a method yielding low counts. It is shown that for the identification of regrowth events HPC(R2A) gives a further margin of about 2 weeks for reaction before HPC(GDWR). Copyright 2003 Elsevier B.V.
Robinson, H.P.
1960-06-01
An automatic counter of alpha particle tracks recorded by a sensitive emulsion of a photographic plate is described. The counter includes a source of mcdulated dark-field illumination for developing light flashes from the recorded particle tracks as the photographic plate is automatically scanned in narrow strips. Photoelectric means convert the light flashes to proportional current pulses for application to an electronic counting circuit. Photoelectric means are further provided for developing a phase reference signal from the photographic plate in such a manner that signals arising from particle tracks not parallel to the edge of the plate are out of phase with the reference signal. The counting circuit includes provision for rejecting the out-of-phase signals resulting from unoriented tracks as well as signals resulting from spurious marks on the plate such as scratches, dust or grain clumpings, etc. The output of the circuit is hence indicative only of the tracks that would be counted by a human operator.
Reyes, Mayra I; Pérez, Cynthia M; Negrón, Edna L
2008-03-01
Consumers increasingly use bottled water and home water treatment systems to avoid direct tap water. According to the International Bottled Water Association (IBWA), an industry trade group, 5 billion gallons of bottled water were consumed by North Americans in 2001. The principal aim of this study was to assess the microbial quality of in-house and imported bottled water for human consumption, by measurement and comparison of the concentration of bacterial endotoxin and standard cultivable methods of indicator microorganisms, specifically, heterotrophic and fecal coliform plate counts. A total of 21 brands of commercial bottled water, consisting of 10 imported and 11 in-house brands, selected at random from 96 brands that are consumed in Puerto Rico, were tested at three different time intervals. The Standard Limulus Amebocyte Lysate test, gel clot method, was used to measure the endotoxin concentrations. The minimum endotoxin concentration in 63 water samples was less than 0.0625 EU/mL, while the maximum was 32 EU/mL. The minimum bacterial count showed no growth, while the maximum was 7,500 CFU/mL. Bacterial isolates like P. fluorescens, Corynebacterium sp. J-K, S. paucimobilis, P. versicularis, A. baumannii, P. chlororaphis, F. indologenes, A. faecalis and P. cepacia were identified. Repeated measures analysis of variance demonstrated that endotoxin concentration did not change over time, while there was a statistically significant (p < 0.05) decrease in bacterial count over time. In addition, multiple linear regression analysis demonstrated that a unit change in the concentration of endotoxin across time was associated with a significant (p < 0.05) reduction in the bacteriological cell count. This analysis evidenced a significant time effect in the average log bacteriological cell count. Although bacterial growth was not detected in some water samples, endotoxin was present. Measurement of Gram-negative bacterial endotoxins is one of the methods that have been suggested as a rapid way of determining bacteriological water quality.
Souto, Luís I M; Minagawa, Clarice Y; Telles, Evelise O; Garbuglio, Márcio A; Amaku, Marcos; Melville, Priscilla A; Dias, Ricardo A; Sakata, Sonia T; Benites, Nilson R
2010-02-01
Milk is the normal secretion of the mammary gland, practically free of colostrum and obtained by the complete milking of one or more healthy animals. Mastitis is an inflammatory process of the mammary gland and it may cause alterations in the milk. The present work aimed to verify whether it is possible, by means of the counts of microorganism in the bulk raw milk in four selective culture media, to establish a correlation with the occurrence of mastitis and therefore, to monitor this disease in bovine dairy herds. The following selective culture media were used: KF Streptococcus Agar, Edwards Agar, Baird-Parker Agar, Blood Agar plus potassium tellurite. Spearman's correlation coefficient was calculated in order to compare the occurrence of mastitis (percentage) in each herd with respective selective culture media counts of microorganisms in bulk raw milk. Thirty-six possibilities were analysed (Tamis and CMT-positive rates were compared with the log-transformed count in four selective culture media) and there was a negative correlation between Tamis 3 and the Baird-Parker Agar plate count. The total results of microbiological tests showed that there were three correlations of the counts in selective culture media. Fifty-two possibilities were analysed and there was a negative correlation between no-bacterial-growth mastitis rates and log10 of KF Streptoccocus Agar plate count and there were two positive correlations between coagulase-positive staphylococci and log10 of Baird-Parker Agar plate count and Blood Agar plus potassium tellurite plate count.
Regulation of Glucose Utilization by Estradiol in Breast Cancer
2014-10-01
counts/min) weremeasured using 350 l of lysate. Protein concentration was determined using the BCA assay according to the manufacturer’s...instructions and measured on a Powerwave XS plate reader (Biotek). Counts were normalized to protein concentration. Glycolysis Assay—MCF-7 cells growing in 6...determined using the BCA assay according to the manufacturer’s instructions and mea- sured on a Powerwave XS plate reader. Counts were normal- ized to
Oketič, K; Matijašić, B Bogovič; Obermajer, T; Radulović, Z; Lević, S; Mirković, N; Nedović, V
2015-01-01
The aim of the study was to evaluate real-time PCR coupled with propidium monoazide (PMA) treatment for enumeration of microencapsulated probiotic lactobacilli microencapsulated in calcium alginate beads. Lactobacillus gasseri K7 (CCM 7710) and Lactobacillus delbrueckii subsp. bulgaricus (CCM 7712) were analysed by plate counting and PMA real-time PCR during storage at 4 °C for 90 days. PMA was effective in preventing PCR amplification of the target sequences of DNA released from heat-compromised bacteria. The values obtained by real-time PCR of non-treated samples were in general higher than those obtained by real-time PCR of PMA-treated samples or by plate counting, indicating the presence of sub-lethally injured cells. This study shows that plate count could not be completely replaced by culture independent method PMA real-time PCR for enumeration of probiotics, but may rather complement the well-established plate counting, providing useful information about the ratio of compromised bacteria in the samples.
Martin, N H; Ranieri, M L; Murphy, S C; Ralyea, R D; Wiedmann, M; Boor, K J
2011-03-01
Analytical tools that accurately predict the performance of raw milk following its manufacture into commercial food products are of economic interest to the dairy industry. To evaluate the ability of currently applied raw milk microbiological tests to predict the quality of commercially pasteurized fluid milk products, samples of raw milk and 2% fat pasteurized milk were obtained from 4 New York State fluid milk processors for a 1-yr period. Raw milk samples were examined using a variety of tests commonly applied to raw milk, including somatic cell count, standard plate count, psychrotrophic bacteria count, ropy milk test, coliform count, preliminary incubation count, laboratory pasteurization count, and spore pasteurization count. Differential and selective media were used to identify groups of bacteria present in raw milk. Pasteurized milk samples were held at 6°C for 21 d and evaluated for standard plate count, coliform count, and sensory quality throughout shelf-life. Bacterial isolates from select raw and pasteurized milk tests were identified using 16S ribosomal DNA sequencing. Linear regression analysis of raw milk test results versus results reflecting pasteurized milk quality consistently showed low R(2) values (<0.45); the majority of R(2) values were <0.25, indicating small relationship between the results from the raw milk tests and results from tests used to evaluate pasteurized milk quality. Our findings suggest the need for new raw milk tests that measure the specific biological barriers that limit shelf-life and quality of fluid milk products. Copyright © 2011 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
Hashimoto, Muneaki; Yatsushiro, Shouki; Yamamura, Shohei; Tanaka, Masato; Sakamoto, Hirokazu; Ido, Yusuke; Kajimoto, Kazuaki; Bando, Mika; Kido, Jun-Ichi; Kataoka, Masatoshi
2017-08-08
Malaria is a red blood cell (RBC) infection caused by Plasmodium parasites. To determine RBC infection rate, which is essential for malaria study and diagnosis, microscopic evaluation of Giemsa-stained thin blood smears on glass slides ('Giemsa microscopy') has been performed as the accepted gold standard for over 100 years. However, only a small area of the blood smear provides a monolayer of RBCs suitable for determination of infection rate, which is one of the major reasons for the low parasite detection rate by Giemsa microscopy. In addition, because Giemsa microscopy is exacting and time-consuming, automated counting of infection rates is highly desirable. A method that allows for microscopic examination of Giemsa-stained cells spread in a monolayer on almost the whole surface of hydrophilic-treated cyclic olefin copolymer (COC) plates was established. Because wide-range Giemsa microscopy can be performed on a hydrophilic-treated plate, the method may enable more reliable diagnosis of malaria in patients with low parasitaemia burden. Furthermore, the number of RBCs and parasites stained with a fluorescent nuclear staining dye could be counted automatically with a software tool, without Giemsa staining. As a result, researchers studying malaria may calculate the infection rate easily, rapidly, and accurately even in low parasitaemia. Because the running cost of these methods is very low and they do not involve complicated techniques, the use of hydrophilic COC plates may contribute to improved and more accurate diagnosis and research of malaria.
Chon, Jung-Whan; Kim, Hong-Seok; Kim, Hyunsook; Oh, Deog-Hwan; Seo, Kun-Ho
2014-05-01
Potassium-clavulanate-supplemented modified charcoal-cefoperazone-deoxycholate agar (C-mCCDA) that was described in our previous study was compared with original mCCDA for the enumeration of Campylobacter in pure culture and chicken carcass rinse. The quantitative detection of viable Campylobacter cells from a pure culture, plated on C-mCCDA, is statistically similar (P > 0.05) to mCCDA. In total, 120 chickens were rinsed using 400 mL buffered peptone water. The rinses were inoculated onto C-mCCDA and mCCDA followed by incubation at 42 °C for 48 h. There was no statistical difference between C-mCCDA (45 of 120 plates; mean count, 145.5 CFU/mL) and normal mCCDA (46 of 120 plates; mean count, 160.8 CFU/mL) in the isolation rate and recovery of Campylobacter (P > 0.05) from chicken carcass rinse. The Pearson correlation coefficient value for the number of Campylobacter cells recovered in the 2 media was 0.942. However, the selectivity was much better on C-mCCDA than on mCCDA plates (P < 0.05). Significantly fewer C-mCCDA plates (33 out of 120 plates; mean count, 1.9 CFU/mL) were contaminated with non-Campylobacter cells than the normal mCCDA plates (67 out of 120 plates; mean count, 27.1 CFU/mL). The C-mCCDA may provide improved results for enumeration of Campylobacter in chicken meat alternative to mCCDA with its increased selectivity the modified agar possess. © 2014 Institute of Food Technologists®
A comparison of legionella and other bacteria concentrations in cooling tower water
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cappabianca, R.M.; Jurinski, N.B.; Jurinski, J.B.
1994-05-01
A field study was conducted in which water samples collected from air conditioning cooling water reservoirs of high-rise buildings throughout an urban area were assayed for Legionella and for total bacteria. Buildings included within the study had ongoing biocidal treatment programs for the cooling towers. Separate sample analyses were performed to measure the viable colony concentrations of total bacteria and of Legionella in the process waters. The occurrence and viable counts of Legionella in 304 environmental water samples were determined by inoculating them onto plates of buffered charcoal yeast extract (BCYE) agar medium (a presumptive screening method). The samples weremore » collected during summer months between July and September. BCYE plate cultures of 50 (16.4%) of the samples yielded Legionella with viable counts ranging from 2 to 608 colony forming units per milliliter. In the water samples, 281 (92.4%) yielded viable counts of bacteria that ranged from 9 to 1.2 x 10{sup 6} per milliliter. This study demonstrates that Legionella are commonly present in the water of air conditioning cooling towers and that there is no significant correlation between concurrently sampled culture plate counts of Legionella and total bacteria plate counts. Correspondingly, there is no demonstrated validity for use of total bacterial counts as an inferential surrogate for the concentration of Legionella in the water. 19 refs., 3 figs., 1 tab.« less
Zhang, Can; Liu, Wen-jun; Ao, Lu; Shi, Yun; An, Dai-zhi; Liu, Zhi-ping
2015-12-01
A survey of endotoxin activity in groundwater from 14 self-contained wells in PLA units stationed in Beijing was conducted by the kinetic-turbid assay of Tachypleus Amebocyte Lysate (TAL). Bacteriological parameters, including total cell counts detected by flow cytometry, heterotrophic plate counts (HPC), standard plate counts and total coliforms were analyzed. Additionally, suspended particles, turbidity, dissolved organic carbon (DOC), and UV₂₅₄ were investigated. Total endotoxin activities ranged from 0. 15 to 13.20 EU · mL⁻¹, free endotoxin activities ranged from 0.10 to 5.29 EU · mL⁻¹ and bound endotoxin activities ranged from 0.01 to 8.60 EU · mL⁻¹. Most of the endotoxins in heavily contaminated groundwater existed as bound endotoxins. As for total endotoxins, the sequence of correlation coefficients with other parameters was total cell counts (r = 0.88 ) > HPC (r = 0.79) > DOC (r = 0.77) > UV₂₅₄ (r = 0.57) > total coliforms (r = 0.50) > standard plate counts (r = 0.49) = turbidity (r = 0. 49) > total particles (r = 0.41). The sequence of correlations of the bound endotoxins with other parameters was total cell counts (r = 0.81) > HPC (r = 0.66) > total coliforms (r = 0.65) > turbidity (r = 0.62) > total particles (r = 0.58) > standard plate counts (r = 0.22). Free endotoxins were correlated with DOC and UV₂₅₄, r = 0.58 and 0.26, respectively. Result showed free endotoxins had a higher correlation with DOC, and a lower correlation with UV₂₅₄.
McConville, John F.; Anger, Claude B.; Anderson, David W.
1974-01-01
An aqueous diluent containing Tween 60 and Arlacel 80 gave greater recovery of microorganisms when compared with two common diluents as determined by aerobic plate count of inoculated anhydrous cosmetics. The greater recovery was caused by better dispersion of the anhydrous cosmetics in the diluents. Images PMID:4203790
Accurate live and dead bacterial cell enumeration using flow cytometry (Conference Presentation)
NASA Astrophysics Data System (ADS)
Ou, Fang; McGoverin, Cushla; Swift, Simon; Vanholsbeeck, Frédérique
2017-03-01
Flow cytometry (FCM) is based on the detection of scattered light and fluorescence to identify cells with particular characteristics of interest. However most FCM cannot precisely control the flow through its interrogation point and hence the volume and concentration of the sample cannot be immediately obtained. The easiest, most reliable and inexpensive way of obtaining absolute counts with FCM is by using reference beads. We investigated a method of using FCM with reference beads to measure live and dead bacterial concentration over the range of 106 to 108 cells/mL and ratio varying from 0 to 100%. We believe we are the first to use this method for such a large cell concentration range while also establishing the effect of varying the live/dead bacteria ratios. Escherichia coli solutions with differing ratios of live:dead cells were stained with fluorescent dyes SYTO 9 and propidium iodide (PI), which label live and dead cells, respectively. Samples were measured using a LSR II Flow Cytometer (BD Biosciences); using 488 nm excitation with 20 mW power. Both SYTO 9 and PI fluorescence were collected and threshold was set to side scatter. Traditional culture-based plate count was done in parallel to the FCM analysis. The concentration of live bacteria from FCM was compared to that obtained by plate counts. Preliminary results show that the concentration of live bacteria obtained by FCM and plate counts correlate well with each other and indicates this may be extended to a wider concentration range or for studying other cell characteristics.
Microbiological survey of a South African poultry processing plant.
Geornaras, I; de Jesus, A; van Zyl, E; von Holy, A
1995-01-01
Bacterial populations associated with poultry processing were determined on neck skin samples, equipment surfaces and environmental samples by replicate surveys. Aerobic plate counts, Enterobacteriaceae counts, Enterobacteriaceae counts and Pseudomonas counts were performed by standard procedures and the prevalence of Listeria, presumptive Salmonella and Staphylococcus aureus determined. Statistically significant (P < 0.05) increases in counts of all types of bacteria were obtained on product samples as a result of processing. Although bacterial counts on neck skin samples decreased by 0.3 to 0.4 log CFU g-1 after spray washing of carcasses, subsequent spinchilling and packaging of whole carcasses resulted in 0.7 to 1.2 log CFU g-1 increases. Bacterial numbers on equipment surfaces, however, decreased significantly from the "dirty" to the "clean" areas of the abattoir. Transport cages, "rubber fingers", defeathering curtains, shackles and conveyor belts repeatedly showed aerobic plate counts in excess of 5.0 log CFU 25 cm-2. Aerobic plate counts of scald tank and spinchiller water were 2 log CFU ml-1 higher than those of potable water samples. Bacterial numbers of the air in the "dirty" area were higher than those of the "clean" area. Listeria, presumptive Salmonella and Staphylococcus aureus were isolated from 27.6, 51.7 and 24.1% of all product samples, respectively, and Listeria and Staphylococcus aureus were also isolated from selected equipment surfaces.
McCarron, J L; Keefe, G P; McKenna, S L B; Dohoo, I R; Poole, D E
2009-05-01
The objective was to determine test characteristics and compare 2 potential on-farm culture systems for clinical mastitis, the Minnesota Easy Culture System II Bi-plate and Petrifilm. The tests were evaluated using clinically positive mastitic milk samples (n = 282) to determine their ability to differentiate appropriate treatment groups; all cases that had gram-positive growth were considered treatment candidates (n = 161), whereas cases that grew gram-negative organisms only or yielded no bacterial growth were classified as no treatment (n = 121). For Petrifilm, both undiluted and 1:10 diluted milk samples were used. To create treatment categories, 2 types of Petrifilms were used, Aerobic Count (AC) and Coliform Count (CC). Both Bi-plates and Petrifilms were read after 24 h of incubation. Analysis was conducted at various colony count thresholds for the Petrifilm test system. The combination of Petrifilms that had the highest sensitivity classified a case as gram-negative if there were > or =20 colonies present on the CC. If there were <20 colonies present on the CC and >5 colonies present on the AC, a case would be classified as gram-positive. The Bi-plate had a sensitivity of 97.9% and a specificity of 68.6%. The Petrifilm test system had a sensitivity of 93.8% and a specificity of 70.1%. There was no significant difference in the sensitivities between the tests. All Bi-plates and Petrifilms were read by a laboratory technician and a group of masked readers with limited microbiology training. Kappa values for the masked readers were 0.75 for Bi-plates and 0.84 and 0.86 for AC and CC Petrifilms, respectively. The Bi-plate and Petrifilm were able to successfully categorize clinical cases of mastitis into 2 treatments based on their ability to detect the presence of a gram-positive organism. Neither method had the ability to determine if a sample was contaminated. The results of this study indicate that both tests were able to appropriately categorize cases, which could potentially result in a reduction in the quantity of antibiotics used to treat clinical cases of mastitis.
Bankier, Claire; Cheong, Yuen; Mahalingam, Suntharavathanan; Edirisinghe, Mohan; Ren, Guogang; Cloutman-Green, Elaine; Ciric, Lena
2018-01-01
Bacterial cell quantification after exposure to antimicrobial compounds varies widely throughout industry and healthcare. Numerous methods are employed to quantify these antimicrobial effects. With increasing demand for new preventative methods for disease control, we aimed to compare and assess common analytical methods used to determine antimicrobial effects of novel nanoparticle combinations on two different pathogens. Plate counts of total viable cells, flow cytometry (LIVE/DEAD BacLight viability assay) and qPCR (viability qPCR) were used to assess the antimicrobial activity of engineered nanoparticle combinations (NPCs) on Gram-positive (Staphylococcus aureus) and Gram-negative (Pseudomonas aeruginosa) bacteria at different concentrations (0.05, 0.10 and 0.25 w/v%). Results were analysed using linear models to assess the effectiveness of different treatments. Strong antimicrobial effects of the three NPCs (AMNP0-2) on both pathogens could be quantified using the plate count method and flow cytometry. The plate count method showed a high log reduction (>8-log) for bacteria exposed to high NPC concentrations. We found similar antimicrobial results using the flow cytometry live/dead assay. Viability qPCR analysis of antimicrobial activity could not be quantified due to interference of NPCs with qPCR amplification. Flow cytometry was determined to be the best method to measure antimicrobial activity of the novel NPCs due to high-throughput, rapid and quantifiable results.
Chen, Huibin; Liu, Zhiyu; Wang, Meiying; Chen, Shaojun; Chen, Tuanwei
2013-12-01
The spoilage bacterial community in oyster gill was investigated during storage at 4, 10 and 20 °C. Aerobic plate counts and pH values were determined. Total bacterial DNA was extracted from oyster gill and bulk cells of plate count media. The major bacterial species during fresh or different temperatures storage were determined by polymerase chain reaction-denaturing gradient gel electrophoresis (PCR-DGGE). The initial aerobic plate count in oyster gill reached 6.70 log CFU g(-1). PCR-DGGE fingerprinting analysis of the 16S rRNA gene V3 region revealed that most of the strains in fresh oyster gill belonged to the genera Lactococcus and Enterobacter. The major spoilage bacteria at a storage temperature of 20 °C were Leuconostoc pseudomesenteroides, an uncultured bacterium, Cytophaga fermentans, Lactococcus lactis, Pseudoalteromonas sp., Enterococcus mundtii, Clostridium difficile and an uncultured Fusobacteria; those at 10 °C were Lactococcus spp., Lactobacillus curvatus, Weissella confusa and C. difficile; those at 4 °C were Lactococcus, Weissella, Enterobacter and Aeromonas. The other minor species were L. curvatus, Pseudomonas sp. and E. mundtii. Lactococcus spp. was the most common main spoilage bacteria in oyster gill during chilled storage. PCR-DGGE revealed the complexity of the bacterial microbiota and the major bacteria species in oyster gill for fresh and storage. © 2013 Society of Chemical Industry.
O'Mahony, Fiach C.; Papkovsky, Dmitri B.
2006-01-01
A simple method has been developed for the analysis of aerobic bacteria in complex samples such as broth and food homogenates. It employs commercial phosphorescent oxygen-sensitive probes to monitor oxygen consumption of samples containing bacteria using standard microtiter plates and fluorescence plate readers. As bacteria grow in aqueous medium, at certain points they begin to deplete dissolved oxygen, which is seen as an increase in probe fluorescence above baseline signal. The time required to reach threshold signal is used to either enumerate bacteria based on a predetermined calibration or to assess the effects of various effectors on the growth of test bacteria by comparison with an untreated control. This method allows for the sensitive (down to a single cell), rapid (0.5 to 12 h) enumeration of aerobic bacteria without the need to conduct lengthy (48 to 72 h) and tedious colony counts on agar plates. It also allows for screening a wide range of chemical and environmental samples for their toxicity. These assays have been validated with different bacteria, including Escherichia coli, Micrococcus luteus, and Pseudomonas fluorescens, with the enumeration of total viable counts in broth and industrial food samples (packaged ham, chicken, and mince meat), and comparison with established agar plating and optical-density-at-600-nm assays has been given. PMID:16461677
Ingham, S C; Hu, Y; Ané, C
2011-08-01
The objective of this study was to evaluate possible claims by advocates of small-scale dairy farming that milk from smaller Wisconsin farms is of higher quality than milk from larger Wisconsin farms. Reported bulk tank standard plate count (SPC) and somatic cell count (SCC) test results for Wisconsin dairy farms were obtained for February to December, 2008. Farms were sorted into 3 size categories using available size-tracking criteria: small (≤118 cows; 12,866 farms), large (119-713 cattle; 1,565 farms), and confined animal feeding operations (≥714 cattle; 160 farms). Group means were calculated (group=farm size category) for the farms' minimum, median, mean, 90th percentile, and maximum SPC and SCC. Statistical analysis showed that group means for median, mean, 90th percentile, and maximum SPC and SCC were almost always significantly higher for the small farm category than for the large farm and confined animal feeding operations farm categories. With SPC and SCC as quality criteria and the 3 farm size categories of ≤118, 119 to 713, and ≥714 cattle, the claim of Wisconsin smaller farms producing higher quality milk than Wisconsin larger farms cannot be supported. Copyright © 2011 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
SURVIVAL OF SALMONELLA SPECIES IN RIVER WATER.
The survival of four Salmonella strains in river water microcosms was monitored using culturing techniques, direct counts, whole cell hybridization, scanning electron microscopy, and resuscitation techniques via the direct viable count method and flow cytrometry. Plate counts of...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fliermans, C.B.; Dougherty, J.M.; Franck, M.M.
Effective in situ bioremediation strategies require an understanding of the effects pollutants and remediation techniques have on subsurface microbial communities. Therefore, detailed characterization of a site`s microbial communities is important. Subsurface sediment borings and water samples were collected from a trichloroethylene (TCE) contaminated site, before and after horizontal well in situ air stripping and bioventing, as well as during methane injection for stimulation of methane-utilizing microorganisms. Subsamples were processed for heterotrophic plate counts, acridine orange direct counts (AODC), community diversity, direct fluorescent antibodies (DFA) enumeration for several nitrogen-transforming bacteria, and Biolog {reg_sign} evaluation of enzyme activity in collected water samples.more » Plate counts were higher in near-surface depths than in the vadose zone sediment samples. During the in situ air stripping and bioventing, counts increased at or near the saturated zone, remained elevated throughout the aquifer, but did not change significantly after the air stripping. Sporadic increases in plate counts at different depths as well as increased diversity appeared to be linked to differing lithologies. AODCs were orders of magnitude higher than plate counts and remained relatively constant with depth except for slight increases near the surface depths and the capillary fringe. Nitrogen-transforming bacteria, as measured by serospecific DFA, were greatly affected both by the in situ air stripping and the methane injection. Biolog{reg_sign} activity appeared to increase with subsurface stimulation both by air and methane. The complexity of subsurface systems makes the use of selective monitoring tools imperative.« less
Moosavi-Nasab, Marzieh; Shad, Ehsan; Ziaee, Esmaeil; Yousefabad, Seyyed Hossein Asadi; Golmakani, Mohammad Taghi; Azizinia, Mehdi
2016-06-01
Chitosan (Ch) coating incorporated with black pepper essential oil (Ch+BPEO) was studied to extend the shelf life of common carp (Cyprinus carpio) during refrigerated storage at 4 ± 1°C. The chemical composition of BPEO was characterized using gas chromatography-mass spectrometry (GC-MS). Antibacterial properties of BPEO were determined by disk diffusion agar, MIC, and MBC. Ch (2% [wt/vol]) and Ch+BPEO (2% [wt/vol] Ch with 1.5% [vol/vol] BPEO) were used for common carp fillet coating. The samples were analyzed periodically for chemical (pH, total volatile basic nitrogen) and microbiological (aerobic plate count, psychrophilic bacteria count, lactic acid bacteria, and Enterobacteriaceae bacterial counts) characteristics during 16 days. The GC-MS results indicated that main components in BPEO were carene, caryophyllene, limonene, β-pinene, and α-pinene. The samples coated with Ch and Ch+BPEO resulted in lower pH and total volatile basic nitrogen values in comparison with the control. The microbiological analysis of fish fillets during refrigerated storage clearly indicated that Ch+BPEO coating significantly reduced the fish fillet microbial load. The aerobic plate count, psychrophilic bacteria count, lactic acid bacteria count, and Enterobacteriaceae bacterial count of samples coated with Ch+BPEO were reduced approximately 4.1, 3.9, 2.3, and 2.8 log CFU/g, respectively, at the end of the storage period. Finally, Ch and Ch+BPEO effectively improved the quality of fish fillet during refrigerated storage and extended the shelf life of fish fillets from 8 to 16 days. Black pepper; Chitosan; Common carp; Essential oil.
SURVIVAL OF SALMONELLA SPECIES IN RIVER WATER
The survival of four Salmonella strains in river water microcosms was monitored by culturing techniques, direct counts, whole-cell hybridization, scanning electron microscopy, and resuscitation techniques via the direct viable count method and flow cytometry. Plate counts of bact...
Hallas, Gary; Monis, Paul
2015-01-01
The enumeration of bacteria using plate-based counts is a core technique used by food and water microbiology testing laboratories. However, manual counting of bacterial colonies is both time and labour intensive, can vary between operators and also requires manual entry of results into laboratory information management systems, which can be a source of data entry error. An alternative is to use automated digital colony counters, but there is a lack of peer-reviewed validation data to allow incorporation into standards. We compared the performance of digital counting technology (ProtoCOL3) against manual counting using criteria defined in internationally recognized standard methods. Digital colony counting provided a robust, standardized system suitable for adoption in a commercial testing environment. The digital technology has several advantages:•Improved measurement of uncertainty by using a standard and consistent counting methodology with less operator error.•Efficiency for labour and time (reduced cost).•Elimination of manual entry of data onto LIMS.•Faster result reporting to customers.
Mosupye, F M; von Holy, A
2000-11-01
One hundred and thirty-two samples of beef, chicken, salad and gravy were collected from two street vendors over eleven replicate surveys to assess microbiological safety and quality. For each food type samples were collected during preparation and holding. Dish water was also collected and food preparation surfaces swabbed during preparation and display. Standard methods were used to determine aerobic plate counts, Enterobacteriaceae counts, coliform counts and spore counts. Six hundred and seventy-five predominant colonies were isolated from aerobic plate counts of all samples and characterised. The incidence of selected foodborne bacterial pathogens and non-pathogenic E. coli 1 was also determined. In most cases mean bacterial counts of the raw materials were significantly higher (P < 0.05) than those of corresponding cooked foods. No significant differences (P > 0.05) in all count types were observed between food samples collected during cooking and those collected during holding. In addition, no significant differences (P > 0.05) in all count types were observed between prepared salads and their raw materials. Mean bacterial counts of water and swab samples collected from vendor 1 were lower than those of water and swab samples collected from vendor 2.The predominant populations isolated from the aerobic plate counts were Bacillus spp., Staphylococcus spp., Enterobacteriaceae and Alcaligenes spp. Bacillus cereus was detected in 17%, Clostridium perfringens in 1%, Staphylococcus aureus in 3% and Vibrio metchnikovii in 2% of the food samples. Campylobacter jejuni, Listeria monocytogenes, and Escherichia coli O157:H7 were not detected. Non-pathogenic E. coli 1 was detected in 13% of food samples, in 86 and 36% of dish water samples collected from vendors 1 and 2, respectively, and in 36% of surface swab samples from vendor 2.
Tandon, Puja; Chhibber, Sanjay; Reed, Robert H
2005-07-01
The detection and enumeration of indicator bacteria such as Escherichia coli is used to assess the extent of faecal contamination of drinking water. On the basis of this approach, the effectiveness of storing water contaminated with faecal indicator bacteria in brass or earthern vessels (mutkas) of the type used in rural India have been investigated. Suspensions of bacteria in sterile distilled water were maintained for up to 48 h in each vessel and enumerated by surface plate counts on nutrient agar (non-selective) and several selective coliform media at 37 degrees C either under standard aerobic conditions, or under conditions designed to neutralise reactive oxygen species (ROS), e.g. using an anaerobic cabinet to prepare plates of pre-reduced growth medium or by inclusion of sodium pyruvate in the growth medium, with incubation of aerobically-prepared plates in an anaerobic jar. The counts obtained for E. coli decreased on short-term storage in a brass mutka; counts for selective media were lower than for equivalent counts for non-selective medium, with ROS-neutralised conditions giving consistently higher counts than aerobic incubation. However, after 48 h, no bacteria were cultivable under any conditions. Similar results were obtained using water from environmental sources in the Panjab, and from rural households where brass and earthern mutkas are used for storage of drinking water, with enumeration on selective coliform media (presumptive total coliforms). In all cases results indicated that, while storage of water in a brass mutka can inactivate E. coli and coliforms over a 48 h period, standard aerobic plate counting using selective media may not be fully effective in enumerating sub-lethally damaged bacteria.
Murphy, P; Dal Bello, F; O'Doherty, J; Arendt, E K; Sweeney, T; Coffey, A
2013-07-01
This study was designed to evaluate the effects of algal and yeast β-glucans on the porcine gastrointestinal microbiota, specifically the community of Lactobacillus, Bifidobacterium and coliforms. A total of 48 pigs were fed four diets over a 28-day period to determine the effect that each had on these communities. The control diet consisted of wheat and soya bean meal. The remaining three diets contained wheat and soya bean meal supplemented with β-glucan at 250 g/tonne from Laminaria digitata, Laminaria hyperborea or Saccharomyces cerevisiae. Faecal samples were collected from animals before feeding each diet and after the feeding period. The animals were slaughtered the following day and samples were collected from the stomach, ileum, caecum, proximal colon and distal colon. Alterations in Lactobacillus in the gastrointestinal tract (GIT) were analysed using denaturing gradient gel electrophoresis (DGGE) profiles generated by group-specific 16S rRNA gene PCR amplicons. Plate count analysis was also performed to quantify total coliforms. DGGE profiles indicated that all β-glucan diets provoked the emergence of a richer community of Lactobacillus. The richest community of lactobacilli emerged after feeding L. digitata (LD β-glucan). Plate count analysis revealed that the L. hyperborea (LH β-glucan) diet had a statistically significant effect on the coliform counts in the proximal colon in comparison with the control diet. β-glucan from L. digitata and S. cerevisiae also generally reduced coliforms but to a lesser extent. Nevertheless, the β-glucan diets did not significantly reduce levels of Lactobacillus or Bifidobacterium. DGGE analysis of GIT samples indicated that the three β-glucan diets generally promoted the establishment of a more varied range of Lactobacillus species in the caecum, proximal and distal colon. The LH β-glucan had the most profound reducing effect on coliform counts when compared with the control diet and diets supplemented with L. digitata and S. cerevisiae β-glucans.
Project environmental microbiology as related to planetary quarantine
NASA Technical Reports Server (NTRS)
Pflug, I. J.
1974-01-01
Microbiological analyses of soil particles allow for the following conclusions: (1) there is a considerable range in the values of aerobic, mesophilic microbial counts associated with different size soil fractions; (2) as soil particle size increases, there is an increase in the mean microbial concentration per particle; (3) plate counts of aerobic, mesophilic organisms in unheated soils yielded a mean concentration of about six organisms per particle for the smallest soil fraction; (4) aerobic, mesophilic counts for sonicated particles heated at 80 C for 20 minutes yielded mean values of about two organisms per particle for the smallest particles; (5) some actinomycetes associated with the soil fractions could survive dry heat treatment at 110 C for one hour; and (6) soil particles stored under ambient laboratory conditions for 2.5 years aerobic, mesophilic plate counts which were comparable or slightly greater than the counts for more recently collected soil.
Pettipher, Graham L.; Mansell, Roderick; McKinnon, Charles H.; Cousins, Christina M.
1980-01-01
Membrane filtration and epifluorescent microscopy were used for the direct enumeration of bacteria in raw milk. Somatic cells were lysed by treatment with trypsin and Triton X-100 so that 2 ml of milk containing up to 5 × 106 somatic cells/ml could be filtered. The majority of the bacteria (ca. 80%) remained intact and were concentrated on the membrane. After being stained with acridine organe, the bacteria fluoresced under ultraviolet light and could easily be counted. The clump count of orange fluorescing cells on the membrane correlated well (r = 0.91) with the corresponding plate count for farm, tanker, and silo milks. Differences between counts obtained by different operators and between the membrane clump count and plate count were not significant. The technique is rapid, taking less than 25 min, inexpensive, costing less than 50 cents per sample, and is suitable for milks containing 5 × 103 to 5 × 108 bacteria per ml. Images PMID:16345515
NASA Astrophysics Data System (ADS)
Wilson, D.; Hopkins, C.
2015-04-01
For bending wave transmission across periodic box-like arrangements of plates, the effects of spatial filtering can be significant and this needs to be considered in the choice of prediction model. This paper investigates the errors that can occur with Statistical Energy Analysis (SEA) and the potential of using Advanced SEA (ASEA) to improve predictions. The focus is on the low- and mid-frequency range where plates only support local modes with low mode counts and the in situ modal overlap is relatively high. To increase the computational efficiency when using ASEA on large systems, a beam tracing method is introduced which groups together all rays with the same heading into a single beam. Based on a diffuse field on the source plate, numerical experiments are used to determine the angular distribution of incident power on receiver plate edges on linear and cuboid box-like structures. These show that on receiver plates which do not share a boundary with the source plate, the angular distribution on the receiver plate boundaries differs significantly from a diffuse field. SEA and ASEA predictions are assessed through comparison with finite element models. With rain-on-the-roof excitation on the source plate, the results show that compared to SEA, ASEA provides significantly better estimates of the receiver plate energy, but only where there are at least one or two bending modes in each one-third octave band. Whilst ASEA provides better accuracy than SEA, discrepancies still exist which become more apparent when the direct propagation path crosses more than three nominally identical structural junctions.
Kiess, A S; Hirai, J H; Triplett, M D; Parker, H M; McDaniel, C D
2016-08-01
The use of antibiotics in poultry is being heavily scrutinized, therefore alternatives such as probiotics are being investigated. Lactobacilli spp. are a commonly used bacteria in formulating probiotics, and the addition of Lactobacilli to broiler diets has demonstrated increased growth rates, stimulated immune systems, and reduced pathogen loads in the gastro-intestinal tract ( GI: ) tract. However, previous research has shown that when rooster semen is directly exposed to Lactobacillus acidophilus (L. acidophilus) sperm quality is reduced. Therefore, the objective of the current study was to determine if oral administration of L. acidophilus increases the concentration of Lactobacilli in semen as well as the cloaca. A total of 30 roosters were used: 15 roosters were gavaged with 1X PBS (Control) and 15 roosters were gavaged with 10(7) cfu/mL of L. acidophilus (Treated). All roosters were gavaged for 14 consecutive days. Semen was collected on a 3 d interval, and cloacal swabs were collected on a 2 d interval, beginning on the first day prior to oral administration. Semen and cloacal swabs were serial diluted, and 100 μL of each dilution was then plated on Man, Rogosa, Sharpe ( MRS: ) agar plates. All plates were incubated for 48 h at 37°C under anaerobic conditions and counted. All Lactobacilli counts were first log transformed, then log transformed (day 0) pre-counts were subtracted from the log transformed day counts providing log differences for the analysis. Seminal Lactobacilli counts were not altered by treatments. However, the main effect of treatment (P = 0.026) for cloacal counts indicated that roosters gavaged with Lactobacilli yielded higher counts than the controls. Additionally, cloaca samples also demonstrated a treatment by day interaction trend (P = 0.082), where Lactobacilli was higher in the L. acidophilus gavaged roosters than the controls only on days 3, 5, 13, and 15. In conclusion, the addition of L. acidophilus to the male breeder diet over extended periods may increase concentrations of Lactobacilli in the cloaca even higher than the concentrations observed in this study. If Lactobacilli reaches high enough concentrations in the cloaca, then sperm quality may be impacted which could lead to poor fertility within the breeder flock. © 2016 Poultry Science Association Inc.
The effect of microchannel plate gain depression on PAPA photon counting cameras
NASA Astrophysics Data System (ADS)
Sams, Bruce J., III
1991-03-01
PAPA (precision analog photon address) cameras are photon counting imagers which employ microchannel plates (MCPs) for image intensification. They have been used extensively in astronomical speckle imaging. The PAPA camera can produce artifacts when light incident on its MCP is highly concentrated. The effect is exacerbated by adjusting the strobe detection level too low, so that the camera accepts very small MCP pulses. The artifacts can occur even at low total count rates if the image has highly a concentrated bright spot. This paper describes how to optimize PAPA camera electronics, and describes six techniques which can avoid or minimize addressing errors.
Koop, G; Dik, N; Nielen, M; Lipman, L J A
2010-06-01
The aims of this study were to assess how different bacterial groups in bulk milk are related to bulk milk somatic cell count (SCC), bulk milk total bacterial count (TBC), and bulk milk standard plate count (SPC) and to measure the repeatability of bulk milk culturing. On 53 Dutch dairy goat farms, 3 bulk milk samples were collected at intervals of 2 wk. The samples were cultured for SPC, coliform count, and staphylococcal count and for the presence of Staphylococcus aureus. Furthermore, SCC (Fossomatic 5000, Foss, Hillerød, Denmark) and TBC (BactoScan FC 150, Foss) were measured. Staphylococcal count was correlated to SCC (r=0.40), TBC (r=0.51), and SPC (r=0.53). Coliform count was correlated to TBC (r=0.33), but not to any of the other variables. Staphylococcus aureus did not correlate to SCC. The contribution of the staphylococcal count to the SPC was 31%, whereas the coliform count comprised only 1% of the SPC. The agreement of the repeated measurements was low. This study indicates that staphylococci in goat bulk milk are related to SCC and make a significant contribution to SPC. Because of the high variation in bacterial counts, repeated sampling is necessary to draw valid conclusions from bulk milk culturing. 2010 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
Microbial contamination in intraoral phosphor storage plates: the dilemma.
de Souza, Tricia Murielly Pereira Andrade; de Castro, Ricardo Dias; de Vasconcelos, Laís César; Pontual, Andréa Dos Anjos; de Moraes Ramos Perez, Flávia Maria; Pontual, Maria Luiza Dos Anjos
2017-01-01
The aims of this study were to evaluate microbial contamination in phosphor storage plates in dental radiology services and discuss the possible origin of this contamination. The sample comprised 50 phosphor plates: 14 plates from service A, 30 from service B, and 6 in the control group, consisting of plates never used. Damp sterile swabs were rubbed on the phosphor plates, and then transferred to tests tubes containing sterile saline solution. Serial dilutions were made, and then inoculated in triplicate on Mueller Hinton agar plates and incubated at 37 °C/48 h, before counting the colony-forming units (CFU). The samples were also seeded in brain-heart infusion medium to confirm contamination by turbidity of the culture medium. All solutions, turbid and clean, were seeded in selective and non-selective media. At service A and B, 50 and 73.3 % of the phosphor plates were contaminated, respectively. This contamination was mainly due to bacteria of the genus Staphylococcus. CFU counts ranged from 26.4 to 80.0 CFU/plate. Most of the phosphor plates evaluated shown to be contaminated, mainly by Staphylococcus ssp. Quantitatively, this contamination occurred at low levels, possibly arising from handling of the plates. The use of a second plastic barrier may have diminished contamination by microorganisms from the oral cavity. There is a risk of cross-contamination by phosphor storage plates used in dental radiology services.
Analysis of Acoustic Emission Parameters from Corrosion of AST Bottom Plate in Field Testing
NASA Astrophysics Data System (ADS)
Jomdecha, C.; Jirarungsatian, C.; Suwansin, W.
Field testing of aboveground storage tank (AST) to monitor corrosion of the bottom plate is presented in this chapter. AE testing data of the ten AST with different sizes, materials, and products were employed to monitor the bottom plate condition. AE sensors of 30 and 150 kHz were used to monitor the corrosion activity of up to 24 channels including guard sensors. Acoustic emission (AE) parameters were analyzed to explore the AE parameter patterns of occurring corrosion compared to the laboratory results. Amplitude, count, duration, and energy were main parameters of analysis. Pattern recognition technique with statistical was implemented to eliminate the electrical and environmental noises. The results showed the specific AE patterns of corrosion activities related to the empirical results. In addition, plane algorithm was utilized to locate the significant AE events from corrosion. Both results of parameter patterns and AE event locations can be used to interpret and locate the corrosion activities. Finally, basic statistical grading technique was used to evaluate the bottom plate condition of the AST.
Kennedy, Deirdre; Cronin, Ultan P.; Wilkinson, Martin G.
2011-01-01
Three common food pathogenic microorganisms were exposed to treatments simulating those used in food processing. Treated cell suspensions were then analyzed for reduction in growth by plate counting. Flow cytometry (FCM) and fluorescence-activated cell sorting (FACS) were carried out on treated cells stained for membrane integrity (Syto 9/propidium iodide) or the presence of membrane potential [DiOC2(3)]. For each microbial species, representative cells from various subpopulations detected by FCM were sorted onto selective and nonselective agar and evaluated for growth and recovery rates. In general, treatments giving rise to the highest reductions in counts also had the greatest effects on cell membrane integrity and membrane potential. Overall, treatments that impacted cell membrane permeability did not necessarily have a comparable effect on membrane potential. In addition, some bacterial species with extensively damaged membranes, as detected by FCM, appeared to be able to replicate and grow after sorting. Growth of sorted cells from various subpopulations was not always reflected in plate counts, and in some cases the staining protocol may have rendered cells unculturable. Optimized FCM protocols generated a greater insight into the extent of the heterogeneous bacterial population responses to food control measures than did plate counts. This study underlined the requirement to use FACS to relate various cytometric profiles generated by various staining protocols with the ability of cells to grow on microbial agar plates. Such information is a prerequisite for more-widespread adoption of FCM as a routine microbiological analytical technique. PMID:21602370
Selective cultivation and rapid detection of Staphylococcus aureus by computer vision.
Wang, Yong; Yin, Yongguang; Zhang, Chaonan
2014-03-01
In this paper, we developed a selective growth medium and a more rapid detection method based on computer vision for selective isolation and identification of Staphylococcus aureus from foods. The selective medium consisted of tryptic soy broth basal medium, 3 inhibitors (NaCl, K2 TeO3 , and phenethyl alcohol), and 2 accelerators (sodium pyruvate and glycine). After 4 h of selective cultivation, bacterial detection was accomplished using computer vision. The total analysis time was 5 h. Compared to the Baird-Parker plate count method, which requires 4 to 5 d, this new detection method offers great time savings. Moreover, our novel method had a correlation coefficient of greater than 0.998 when compared with the Baird-Parker plate count method. The detection range for S. aureus was 10 to 10(7) CFU/mL. Our new, rapid detection method for microorganisms in foods has great potential for routine food safety control and microbiological detection applications. © 2014 Institute of Food Technologists®
Telang, Sucheta; Berseth, Carol Lynn; Ferguson, Paul W; Kinder, Julie M; DeRoin, Mark; Petschow, Bryon W
2005-10-01
To evaluate the growth of resident aerobic mesophilic flora and added Enterobacter sakazakii in fresh, unfortified human milk; fresh human milk fortified with two commercial powdered fortifiers differing in iron content; and infant formula prepared from powder. Eight mothers provided preterm breast milk samples. Breast milk samples were divided into three aliquots: unfortified, fortified with fortifier containing 1.44 mg iron/14 kcal, and fortified with fortifier containing 0.4 mg iron/14 kcal. Aliquots of formula were prepared. Breast milk and formula aliquots were divided into two test samples. Half were inoculated with low amounts of E sakazakii; half were not. All test samples were maintained at room temperature (22 degrees C), serially diluted, and plated onto agars after 0, 2, 4, and 6 hours. Plates were incubated at 35 degrees C and enumerated. Data were analyzed using repeated measures analysis of variance. P<.05 was considered significant. There were no differences in colony counts of aerobic bacteria among uninoculated or among inoculated human milk samples at any time; counts did not increase significantly over 6 hours. There were no differences in colony counts of E sakazakii among inoculated human milk samples at any time; counts did not increase significantly over 6 hours. Aerobic bacteria and E sakazakii colony counts from infant formula did not increase significantly over 6 hours. During 6 hours at 22 degrees C, fresh human milk and formula had negligible bacterial growth; fortifying human milk with powdered fortifiers did not affect bacterial growth.
Narihiro, Takashi; Kanosue, Yuji; Hiraishi, Akira
2016-06-25
This study was undertaken to examine the effects of water activity (aw) on the viability of actinobacterial isolates from a fed-batch composting (FBC) process by comparing culturability and stainability with 5-cyano-2,3-ditoryl tetrazolium chloride (CTC). The FBC reactor as the source of these bacteria was operated with the daily loading of household biowaste for 70 d. During this period of composting, aw in the reactor decreased linearly with time and reached approximately 0.95 at the end of operation. The plate counts of aerobic chemoorganotrophic bacteria were 3.2-fold higher than CTC-positive (CTC+) counts on average at the fully acclimated stage (after 7 weeks of operation), in which Actinobacteria predominated, as shown by lipoquinone profiling and cultivation methods. When the actinobacterial isolates from the FBC process were grown under aw stress, no significant differences were observed in culturability among the cultures, whereas CTC stainability decreased with reductions in aw levels. A cDNA microarray-based transcriptomic analysis of a representative isolate showed that many of the genes involved in cellular metabolism and genetic information processing were down-regulated by aw stress. This result was fully supported by a proteomic analysis. The results of the present study suggest that, in low aw mature compost, the metabolic activity of the community with Actinobacteria predominating is temporarily reduced to a level that hardly reacts with CTC; however, these bacteria are easily recoverable by exposure to a high aw culture medium. This may be a plausible reason why acclimated FBC reactors in which Actinobacteria predominate yields higher plate counts than CTC+ counts.
21 CFR 1210.16 - Method of bacterial count.
Code of Federal Regulations, 2010 CFR
2010-04-01
... Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED... FEDERAL IMPORT MILK ACT Inspection and Testing § 1210.16 Method of bacterial count. The bacterial count of milk and cream refers to the number of viable bacteria as determined by the standard plate method of...
21 CFR 1210.16 - Method of bacterial count.
Code of Federal Regulations, 2011 CFR
2011-04-01
... Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED... FEDERAL IMPORT MILK ACT Inspection and Testing § 1210.16 Method of bacterial count. The bacterial count of milk and cream refers to the number of viable bacteria as determined by the standard plate method of...
A Microbial Community in Sediments Beneath the Western Antarctic Ice Sheet, Ice Stream C (Kamb)
NASA Astrophysics Data System (ADS)
Skidmore, M.; Han, S.; Foo, W.; Bui, D.; Lanoil, B.
2004-12-01
In 2000, an ice-drilling project focusing on the "sticky spot" of Ice Stream C recovered cores of sub-glacial sediments from beneath the Western Antarctic Ice Sheet. We have characterized several chemical and microbiological parameters of the sole intact sediment core. Pore waters extracted from these sediments were brackish and some were supersaturated with respect to calcite. Ion chromatography demonstrated the presence of several organic acids at low, but detectable, levels in the pore water. DAPI direct cell counts were approximately 107 cells g-1. Aerobic viable plate counts were much lower than direct cell counts; however, they were two orders of magnitude higher on plates incubated at low temperature (4 ° C; 3.63 x 105 CFU ml-1) than at higher temperatures (ca. 22° C; 1.5 x 103 CFU ml-1); no colonies were detected on plates incubated anaerobically at either temperature. 16S rDNA clone library analysis indicates extremely limited bacterial diversity in these samples: six phylogenetic clades were detected. The three dominant bacterial phylogenetic clades in the clone libraries (252 clones total) were most closely related to Thiobacillus thioparus (180 clones), Polaromonas vacuolata (34 clones), and Gallionella ferruginea (35 clones) and their relatives; one clone each represented the other three phylogenetic clades (most closely related to Ralstonia pickettii, Lysobacter antibioticus, and Xylella fastidiosa, respectively). These sequences match closely with sequences previously obtained from other subglacial environments in Alaska, Ellesmere Island, Canada and New Zealand. Implications of this microbial community to subglacial chemistry and microbial biogeography will be discussed.
NASA Astrophysics Data System (ADS)
Edwards, Nathaniel S.; Conley, Jerrod C.; Reichenberger, Michael A.; Nelson, Kyle A.; Tiner, Christopher N.; Hinson, Niklas J.; Ugorowski, Philip B.; Fronk, Ryan G.; McGregor, Douglas S.
2018-06-01
The propagation of electrons through several linear pore densities of reticulated vitreous carbon (RVC) foam was studied using a Frisch-grid parallel-plate ionization chamber pressurized to 1 psig of P-10 proportional gas. The operating voltages of the electrodes contained within the Frisch-grid parallel-plate ionization chamber were defined by measuring counting curves using a collimated 241Am alpha-particle source with and without a Frisch grid. RVC foam samples with linear pore densities of 5, 10, 20, 30, 45, 80, and 100 pores per linear inch were separately positioned between the cathode and anode. Pulse-height spectra and count rates from a collimated 241Am alpha-particle source positioned between the cathode and each RVC foam sample were measured and compared to a measurement without an RVC foam sample. The Frisch grid was positioned in between the RVC foam sample and the anode. The measured pulse-height spectra were indiscernible from background and resulted in negligible net count rates for all RVC foam samples. The Frisch grid parallel-plate ionization chamber measurement results indicate that electrons do not traverse the bulk of RVC foam and consequently do not produce a pulse.
Harmon, S Michele; West, Ryan T; Yates, James R
2014-12-01
Sources of fecal coliform pollution in a small South Carolina (USA) watershed were identified using inexpensive methods and commonly available equipment. Samples from the upper reaches of the watershed were analyzed with 3M(™) Petrifilm(™) count plates. We were able to narrow down the study's focus to one particular tributary, Sand River, that was the major contributor of the coliform pollution (both fecal and total) to a downstream reservoir that is heavily used for recreation purposes. Concentrations of total coliforms ranged from 2,400 to 120,333 cfu/100 mL, with sharp increases in coliform counts observed in samples taken after rain events. Positive correlations between turbidity and fecal coliform counts suggested a relationship between fecal pollution and stormwater runoff. Antibiotic resistance analysis (ARA) compared antibiotic resistance profiles of fecal coliform isolates from the stream to those of a watershed-specific fecal source library (equine, waterfowl, canines, and untreated sewage). Known fecal source isolates and unknown isolates from the stream were exposed to six antibiotics at three concentrations each. Discriminant analysis grouped known isolates with an overall average rate of correct classification (ARCC) of 84.3 %. A total of 401 isolates from the first stream location were classified as equine (45.9 %), sewage (39.4 %), waterfowl (6.2 %), and feline (8.5 %). A similar pattern was observed at the second sampling location, with 42.6 % equine, 45.2 % sewage, 2.8 % waterfowl, 0.6 % canine, and 8.8 % feline. While there were slight weather-dependent differences, the vast majority of the coliform pollution in this stream appeared to be from two sources, equine and sewage. This information will contribute to better land use decisions and further justify implementation of low-impact development practices within this urban watershed.
Castillo-Ayala, A; Salas-Ubiarco, M G; Márquez-Padilla, M L; Osorio-Hernández, M D
1993-01-01
The presence of Campylobacter spp. and Salmonella was studied in 70 samples of fresh retail chicken pieces and in 40 samples of roast chicken. Total plate count was performed in every sample as well. Most of the samples of fresh chicken yielded total plate counts > 10(8)/piece (thigh), while in roast chicken these counts ranged from 10(3) to 10(5)/piece (leg and thigh). Campylobacter was isolated from 33% of fresh chicken and from no sample of roast chicken. Salmonella was isolated from 69% of fresh chicken and 2.5% of roast chicken. There was no relationship between total plate counts in fresh chicken and isolation of either Campylobacter or Salmonella. Sixty percent of the Salmonella isolates belonged to serotype S. anatum, and about 50% of the isolates of Campylobacter were identified as being C. coli. The only Salmonella-positive sample of roast chicken yielded three serotypes: S. give, S. muenster, and S. manhattan. Presence of Campylobacter and Salmonella in chicken is of concern, due to the risk of spreading from the raw food to other cooked foods. The isolation of pathogens from roast chicken indicates mishandling during processing and/or storage of the product.
A generalized plate method for estimating total aerobic microbial count.
Ho, Kai Fai
2004-01-01
The plate method outlined in Chapter 61: Microbial Limit Tests of the U.S. Pharmacopeia (USP 61) provides very specific guidance for assessing total aerobic bioburden in pharmaceutical articles. This methodology, while comprehensive, lacks the flexibility to be useful in all situations. By studying the plate method as a special case within a more general family of assays, the effects of each parameter in the guidance can be understood. Using a mathematical model to describe the plate counting procedure, a statistical framework for making more definitive statements about total aerobic bioburden is developed. Such a framework allows the laboratory scientist to adjust the USP 61 methods to satisfy specific practical constraints. In particular, it is shown that the plate method can be conducted, albeit with stricter acceptance criteria, using a test specimen quantity that is smaller than the 10 g or 10 mL prescribed in the guidance. Finally, the interpretation of results proffered by the guidance is re-examined within this statistical framework and shown to be overly aggressive.
Spatial distribution of Legionella pneumophila MLVA-genotypes in a drinking water system.
Rodríguez-Martínez, Sarah; Sharaby, Yehonatan; Pecellín, Marina; Brettar, Ingrid; Höfle, Manfred; Halpern, Malka
2015-06-15
Bacteria of the genus Legionella cause water-based infections, resulting in severe pneumonia. To improve our knowledge about Legionella spp. ecology, its prevalence and its relationships with environmental factors were studied. Seasonal samples were taken from both water and biofilm at seven sampling points of a small drinking water distribution system in Israel. Representative isolates were obtained from each sample and identified to the species level. Legionella pneumophila was further determined to the serotype and genotype level. High resolution genotyping of L. pneumophila isolates was achieved by Multiple-Locus Variable number of tandem repeat Analysis (MLVA). Within the studied water system, Legionella plate counts were higher in summer and highly variable even between adjacent sampling points. Legionella was present in six out of the seven selected sampling points, with counts ranging from 1.0 × 10(1) to 5.8 × 10(3) cfu/l. Water counts were significantly higher in points where Legionella was present in biofilms. The main fraction of the isolated Legionella was L. pneumophila serogroup 1. Serogroup 3 and Legionella sainthelensis were also isolated. Legionella counts were positively correlated with heterotrophic plate counts at 37 °C and negatively correlated with chlorine. Five MLVA-genotypes of L. pneumophila were identified at different buildings of the sampled area. The presence of a specific genotype, "MLVA-genotype 4", consistently co-occurred with high Legionella counts and seemed to "trigger" high Legionella counts in cold water. Our hypothesis is that both the presence of L. pneumophila in biofilm and the presence of specific genotypes, may indicate and/or even lead to high Legionella concentration in water. This observation deserves further studies in a broad range of drinking water systems to assess its potential for general use in drinking water monitoring and management. Copyright © 2015 Elsevier Ltd. All rights reserved.
Bohaychuk, Valerie M.; Checkley, Sylvia L.; Gensler, Gary E.; Barrios, Pablo Romero
2009-01-01
Studies to determine baseline levels of microbial contaminants and foodborne bacterial pathogens are needed to evaluate the effectiveness of Hazard Analysis Critical Control Point (HACCP) programs, Good Manufacturing/Production Practices, and various interventions. In 2004 and 2005 poultry carcass rinses from provincially inspected abattoirs in Alberta, Canada, were tested to determine the levels of aerobic plate count bacteria, coliform bacteria, and generic Escherichia coli, the prevalence and levels of Campylobacter spp., and the prevalence of Salmonella spp. and Shiga toxin-producing E. coli (STEC). Samples were collected from 3 high volume and 62 low volume abbatoirs. All samples (1296) were positive for aerobic plate count bacteria, with 98.8% of samples having counts of 100 000 or less colony forming units (CFU)/cm2. Coliform bacteria were isolated from 99.7% of the 1296 carcasses and were recovered at levels of ≤ 1000 CFU/cm2 for 98.3% of the samples. Generic E. coli were recovered from 99.1% of the 1296 carcasses at levels of ≤ 1000 CFU/cm2 for 98.6% of the samples. Seventy five percent of 1234 samples that were tested for Campylobacter were positive; 37.5% of 1295 samples that were tested for Salmonella were positive; and only 2 of 1296 samples tested for STEC were positive (0.15%). PMID:19412397
Automatic counting and classification of bacterial colonies using hyperspectral imaging
USDA-ARS?s Scientific Manuscript database
Detection and counting of bacterial colonies on agar plates is a routine microbiology practice to get a rough estimate of the number of viable cells in a sample. There have been a variety of different automatic colony counting systems and software algorithms mainly based on color or gray-scale pictu...
Xue, Yong; Wilkes, Jon G.; Moskal, Ted J.; Williams, Anna J.; Cooper, Willie M.; Nayak, Rajesh; Rafii, Fatemeh; Buzatu, Dan A.
2016-01-01
Standard methods to detect Escherichia coli contamination in food use the polymerase chain reaction (PCR) and agar culture plates. These methods require multiple incubation steps and take a long time to results. An improved rapid flow-cytometry based detection method was developed, using a fluorescence-labeled oligonucleotide probe specifically binding a16S rRNA sequence. The method positively detected 51 E. coli isolates as well as 4 Shigella species. All 27 non-E. coli strains tested gave negative results. Comparison of the new genetic assay with a total plate count (TPC) assay and agar plate counting indicated similar sensitivity, agreement between cytometry cell and colony counts. This method can detect a small number of E.coli cells in the presence of large numbers of other bacteria. This method can be used for rapid, economical, and stable detection of E. coli and Shigella contamination in the food industry and other contexts. PMID:26913737
Xue, Yong; Wilkes, Jon G; Moskal, Ted J; Williams, Anna J; Cooper, Willie M; Nayak, Rajesh; Rafii, Fatemeh; Buzatu, Dan A
2016-01-01
Standard methods to detect Escherichia coli contamination in food use the polymerase chain reaction (PCR) and agar culture plates. These methods require multiple incubation steps and take a long time to results. An improved rapid flow-cytometry based detection method was developed, using a fluorescence-labeled oligonucleotide probe specifically binding a16S rRNA sequence. The method positively detected 51 E. coli isolates as well as 4 Shigella species. All 27 non-E. coli strains tested gave negative results. Comparison of the new genetic assay with a total plate count (TPC) assay and agar plate counting indicated similar sensitivity, agreement between cytometry cell and colony counts. This method can detect a small number of E.coli cells in the presence of large numbers of other bacteria. This method can be used for rapid, economical, and stable detection of E. coli and Shigella contamination in the food industry and other contexts.
NASA Astrophysics Data System (ADS)
Watanabe, Kenichi; Minniti, Triestino; Kockelmann, Winfried; Dalgliesh, Robert; Burca, Genoveva; Tremsin, Anton S.
2017-07-01
The uncertainties and the stability of a neutron sensitive MCP/Timepix detector when operating in the event timing mode for quantitative image analysis at a pulsed neutron source were investigated. The dominant component to the uncertainty arises from the counting statistics. The contribution of the overlap correction to the uncertainty was concluded to be negligible from considerations based on the error propagation even if a pixel occupation probability is more than 50%. We, additionally, have taken into account the multiple counting effect in consideration of the counting statistics. Furthermore, the detection efficiency of this detector system changes under relatively high neutron fluxes due to the ageing effects of current Microchannel Plates. Since this efficiency change is position-dependent, it induces a memory image. The memory effect can be significantly reduced with correction procedures using the rate equations describing the permanent gain degradation and the scrubbing effect on the inner surfaces of the MCP pores.
Development of a rapid optic bacteria detecting system based on ATP bioluminescence
NASA Astrophysics Data System (ADS)
Liu, Jun Tao; Luo, JinPing; Liu, XiaoHong; Cai, XinXia
2014-12-01
A rapid optic bacteria detecting system based on the principle of Adenosine triphosphate(ATP) bioluminescence was presented in this paper. This system consisted of bioluminescence-based biosensor and the high-sensitivity optic meter. A photon counting photomultiplier tube (PMT) module was used to improve the detection sensitivity, and a NIOS II/f processor based on a Field Programmable Gate Array(FPGA) was used to control the system. In this work, Micrococcus luteus were chosen as the test sample. Several Micrococcus luteus suspension with different concentration was tested by both T2011 and plate counting method. By comparing the two group results, an calibration curve was obtained from the bioluminescence intensity for Micrococcus luteus in the range of 2.3×102 ~ 2.3×106 CFU/mL with a good correlation coefficient of 0.960. An impacting Air microorganism sampler was used to capture Airborne Bacteria, and 8 samples were collected in different place. The TBC results of 8 samples by T2011 were between 10 ~ 2×103 cfu/mL, consistent with that of plate counting method, which indicated that 8 samples were between 10 ~ 3×103 cfu/mL. For total airborne bacteria count was small, correlation coefficient was poor. Also no significant difference was found between T2011 and plate counting method by statistical analyses.
Low noise and conductively cooled microchannel plates
NASA Technical Reports Server (NTRS)
Feller, W. B.
1990-01-01
Microchannel plate (MCP) dynamic range has recently been enhanced for both very low and very high input flux conditions. Improvements in MCP manufacturing technology reported earlier have led to MCPs with substantially reduced radioisotope levels, giving dramatically lower internal background-counting rates. An update is given on the Galileo low noise MCP. Also, new results in increasing the MCP linear counting range for high input flux densities are presented. By bonding the active face of a very low resistance MCP (less than 1 megaohm) to a substrate providing a conductive path for heat transport, the bias current limit (hence, MCP output count rate limit) can be increased up to two orders of magnitude. Normal pulse-counting MCP operation was observed at bias currents of several mA when a curved-channel MCP (80:1) was bonded to a ceramic multianode substrate; the MCP temperature rise above ambient was less than 40 C.
Photon-counting detector arrays based on microchannel array plates. [for image enhancement
NASA Technical Reports Server (NTRS)
Timothy, J. G.
1975-01-01
The recent development of the channel electron multiplier (CEM) and its miniaturization into the microchannel array plate (MCP) offers the possibility of fully combining the advantages of the photographic and photoelectric detection systems. The MCP has an image-intensifying capability and the potential of being developed to yield signal outputs superior to those of conventional photomultipliers. In particular, the MCP has a photon-counting capability with a negligible dark-count rate. Furthermore, the MCP can operate stably and efficiently at extreme-ultraviolet and soft X-ray wavelengths in a windowless configuration or can be integrated with a photo-cathode in a sealed tube for use at ultraviolet and visible wavelengths. The operation of one- and two-dimensional photon-counting detector arrays based on the MCP at extreme-ultraviolet wavelengths is described, and the design of sealed arrays for use at ultraviolet and visible wavelengths is briefly discussed.
NASA Technical Reports Server (NTRS)
Timothy, J. G.
1976-01-01
The full sensitivity, dynamic range, and photometric stability of microchannel array plates(MCP) are incorporated into a photon-counting detection system for space operations. Components of the system include feedback-free MCP's for high gain and saturated output pulse-height distribution with a stable response; multi-anode readout arrays mounted in proximity focus with the output face of the MCP; and multi-layer ceramic headers to provide electrical interface between the anode array in a sealed detector tube and the associated electronics.
Veggie ISS Validation Test Results and Produce Consumption
NASA Technical Reports Server (NTRS)
Massa, Gioia; Hummerick, Mary; Spencer, LaShelle; Smith, Trent
2015-01-01
The Veggie vegetable production system flew to the International Space Station (ISS) in the spring of 2014. The first set of plants, Outredgeous red romaine lettuce, was grown, harvested, frozen, and returned to Earth in October. Ground control and flight plant tissue was sub-sectioned for microbial analysis, anthocyanin antioxidant phenolic analysis, and elemental analysis. Microbial analysis was also performed on samples swabbed on orbit from plants, Veggie bellows, and plant pillow surfaces, on water samples, and on samples of roots, media, and wick material from two returned plant pillows. Microbial levels of plants were comparable to ground controls, with some differences in community composition. The range in aerobic bacterial plate counts between individual plants was much greater in the ground controls than in flight plants. No pathogens were found. Anthocyanin concentrations were the same between ground and flight plants, while antioxidant and phenolic levels were slightly higher in flight plants. Elements varied, but key target elements for astronaut nutrition were similar between ground and flight plants. Aerobic plate counts of the flight plant pillow components were significantly higher than ground controls. Surface swab samples showed low microbial counts, with most below detection limits. Flight plant microbial levels were less than bacterial guidelines set for non-thermostabalized food and near or below those for fungi. These guidelines are not for fresh produce but are the closest approximate standards. Forward work includes the development of standards for space-grown produce. A produce consumption strategy for Veggie on ISS includes pre-flight assessments of all crops to down select candidates, wiping flight-grown plants with sanitizing food wipes, and regular Veggie hardware cleaning and microbial monitoring. Produce then could be consumed by astronauts, however some plant material would be reserved and returned for analysis. Implementation of this plan is a step toward developing pick-and-eat food production to supplement the packaged diet on ISS and for future exploration missions where plants could make up a larger portion of the diet. Supported by NASA Space Biology Program.
The effect of ice-cream-scoop water on the hygiene of ice cream.
Wilson, I. G.; Heaney, J. C.; Weatherup, S. T.
1997-01-01
A survey of unopened ice cream, ice cream in use, and ice-cream-scoop water (n = 91) was conducted to determine the effect of scoop water hygiene on the microbiological quality of ice cream. An aerobic plate count around 10(6) c.f.u. ml-1 was the modal value for scoop waters. Unopened ice creams generally had counts around 10(3)-10(4) c.f.u. ml-1 and this increased by one order of magnitude when in use. Many scoop waters had low coliform counts, but almost half contained > 100 c.f.u. ml-1. E. coli was isolated in 18% of ice creams in use, and in 10% of unopened ice creams. S. aureus was not detected in any sample. Statistical analysis showed strong associations between indicator organisms and increased counts in ice cream in use. EC guidelines for indicator organisms in ice cream were exceeded by up to 56% of samples. PMID:9287941
The effect of ice-cream-scoop water on the hygiene of ice cream.
Wilson, I G; Heaney, J C; Weatherup, S T
1997-08-01
A survey of unopened ice cream, ice cream in use, and ice-cream-scoop water (n = 91) was conducted to determine the effect of scoop water hygiene on the microbiological quality of ice cream. An aerobic plate count around 10(6) c.f.u. ml-1 was the modal value for scoop waters. Unopened ice creams generally had counts around 10(3)-10(4) c.f.u. ml-1 and this increased by one order of magnitude when in use. Many scoop waters had low coliform counts, but almost half contained > 100 c.f.u. ml-1. E. coli was isolated in 18% of ice creams in use, and in 10% of unopened ice creams. S. aureus was not detected in any sample. Statistical analysis showed strong associations between indicator organisms and increased counts in ice cream in use. EC guidelines for indicator organisms in ice cream were exceeded by up to 56% of samples.
Rapid surface colony counts determination with three new miniaturised techniques.
Malik, K A
1977-01-01
Three different miniaturised methods for the rapid surface viable counting are described. The methods were tried in parallel to seven different existing methods (Table 1) for viable counts and were found to be easier, quicker and insome cases more accurate. The techniques require about 10% of the material and time needed for conventional spread-plates method and the results were in no way inferior to that (Table 1 and 2). Mini agar discs were cut aseptically with an especially designed stainless steel agar disc cutter (25 mm internal and 28 mm external diameter, Fig. 1b) or with a test tube of similar diameter. The area of the resulted mini-agar-disc of 25 mm diameter was kept such (about 1/10th of the normal plate) that the ratio of the colony-bearing area to the inoculm remained the same as on big plates in spread-plate-method (Table 2). In normal Petri dishes (about 90 mm diameter) up to seven mini agar discs were possible to cut. Each small agar disc was seperated from the other mini-disc by a distance of at least 6 mm (Fig. 1a). The empty place around the disc was still enlarged during over drying of the plates and during incubation. This created complete isolation from the neighbouring disc. For micro-determination of surface viable counts 10 micronl from each dilution was delivered on a well-dired mini-disc with a piston micropipette. The inoculm was immediately spread on the whole mini-disc with a specially designed flame sterilizable platinum-Mini-spreader (Fig. 2a). No spinning of the plate was needed. Alternatively the dropping pipette and spreader was replaced by a calibrated platinum wire Loop-spreader (Fig. 2b). A loop of 3 mm internal diameter made from a platinum-iridium wire of 0.75 mm thickness proved most useful and carried a drop of 10 micronl. Differences especially in surface tension of various diluting fluids did not influence to drop of this size and no recalibration was needed for water and nutrient broth. The loop was further shaped to Loop-spreader form. From each bacterial suspension 10 micronl were carried and spread on each mini-disc. The method is useful for pathogenic organisms as the loop can readily be flame sterilized. For routine purposes where only approximate numbers of bacteria need to be known a still rapid semiquantitative method was deviced making use of a calibrated stainless steel Stamping-disc (Fig. 2c). A disc of 25mm diameter and 1 mm thickness delivered approximateyl 10 microlitres of supensions and was found to be most useful to stamp seven dilutions on a single plate. In collections and bacteriology laboratories where by conventional methods large number of plates are to be plated and counted the presented techniques could prove most convenient, rapid and economical.
Bai, Xiaohui; Zhi, Xinghua; Zhu, Huifeng; Meng, Mingqun; Zhang, Mingde
2015-01-01
This study investigates the effect of chloramine residual on bacteria growth and regrowth and the relationship between heterotrophic plate counts (HPCs) and the concentration of chloramine residual in the Shanghai drinking water distribution system (DWDS). In this study, models to control HPCs in the water distribution system and consumer taps are also developed. Real-time ArcGIS was applied to show the distribution and changed results of the chloramine residual concentration in the pipe system by using these models. Residual regression analysis was used to get a reasonable range of the threshold values that allows the chloramine residual to efficiently inhibit bacteria growth in the Shanghai DWDS; the threshold values should be between 0.45 and 0.5 mg/L in pipe water and 0.2 and 0.25 mg/L in tap water. The low residual chloramine value (0.05 mg/L) of the Chinese drinking water quality standard may pose a potential health risk for microorganisms that should be improved. Disinfection by-products (DBPs) were detected, but no health risk was identified.
Quintana, Gabriel; Gerbino, Esteban; Gómez-Zavaglia, Andrea
2017-01-01
Okara is a nutritionally valuable by-product produced in large quantities as result of soymilk elaboration. This work proposes its use as both culture and dehydration medium during freeze-drying, spray-drying, and storage of Lactobacillus plantarum CIDCA 83114. Whole and defatted okara were employed as culture media for L. plantarum CIDCA 83114. The growth kinetics were followed by plate counting and compared with those of bacteria grown in MRS broth (control). No significant differences in plate counting were observed in the three media. The fatty acid composition of bacteria grown in whole and defatted okara showed a noticeable increase in the unsaturated/saturated (U/S) fatty acid ratio, with regard to bacteria grown in MRS. This change was mainly due to the increase in polyunsaturated fatty acids, namely C18:2. For dehydration assays, cultures in the stationary phase were neutralized and freeze-dried (with or without the addition of 250 mM sucrose) or spray-dried. Bacteria were plate counted immediately after freeze-drying or spray-drying and during storage at 4°C for 90 days. Freeze-drying in whole okara conducted to the highest bacterial recovery. Regarding storage, spray-dried bacteria previously grown in whole and defatted okara showed higher plate counts than those grown in MRS. On the contrary, freeze-dried bacteria previously grown in all the three culture media were those with the lowest plate counts. The addition of sucrose to the dehydration media improved their recovery. The higher recovery of microorganisms grown in okara after freeze-drying and spray-drying processes and during storage was ascribed to both the presence of fiber and proteins in the dehydration media, and the increase in U/S fatty acids ratio in bacterial membranes. The obtained results support for the first time the use of okara as an innovative matrix to deliver L. plantarum . Considering that okara is an agro-waste obtained in large quantities, these results represent an innovative strategy to add it value, providing a symbiotic ingredient with promising industrial applications in the development of novel functional foods and feeds.
Quintana, Gabriel; Gerbino, Esteban; Gómez-Zavaglia, Andrea
2017-01-01
Okara is a nutritionally valuable by-product produced in large quantities as result of soymilk elaboration. This work proposes its use as both culture and dehydration medium during freeze-drying, spray-drying, and storage of Lactobacillus plantarum CIDCA 83114. Whole and defatted okara were employed as culture media for L. plantarum CIDCA 83114. The growth kinetics were followed by plate counting and compared with those of bacteria grown in MRS broth (control). No significant differences in plate counting were observed in the three media. The fatty acid composition of bacteria grown in whole and defatted okara showed a noticeable increase in the unsaturated/saturated (U/S) fatty acid ratio, with regard to bacteria grown in MRS. This change was mainly due to the increase in polyunsaturated fatty acids, namely C18:2. For dehydration assays, cultures in the stationary phase were neutralized and freeze-dried (with or without the addition of 250 mM sucrose) or spray-dried. Bacteria were plate counted immediately after freeze-drying or spray-drying and during storage at 4°C for 90 days. Freeze-drying in whole okara conducted to the highest bacterial recovery. Regarding storage, spray-dried bacteria previously grown in whole and defatted okara showed higher plate counts than those grown in MRS. On the contrary, freeze-dried bacteria previously grown in all the three culture media were those with the lowest plate counts. The addition of sucrose to the dehydration media improved their recovery. The higher recovery of microorganisms grown in okara after freeze-drying and spray-drying processes and during storage was ascribed to both the presence of fiber and proteins in the dehydration media, and the increase in U/S fatty acids ratio in bacterial membranes. The obtained results support for the first time the use of okara as an innovative matrix to deliver L. plantarum. Considering that okara is an agro-waste obtained in large quantities, these results represent an innovative strategy to add it value, providing a symbiotic ingredient with promising industrial applications in the development of novel functional foods and feeds. PMID:28446905
Assessment of microbiological quality of retail fresh sushi from selected sources in Norway.
Hoel, Sunniva; Mehli, Lisbeth; Bruheim, Torkjel; Vadstein, Olav; Jakobsen, Anita Nordeng
2015-05-01
Retail fresh sushi is gaining popularity in Europe. This study was conducted to investigate the microbiological quality of selected samples of fresh sushi with a shelf life of 2 to 3 days offered as complete meals in Norwegian supermarkets. Analysis of aerobic plate counts in 58 sushi samples from three producers revealed large variations in microbiological quality, and 48% of the analyzed sushi boxes were rated as unsatisfactory (> 6.0 log CFU/g). Mesophilic Aeromonas spp. was detected in 71% of the samples. In a follow-up study, we collected products and raw materials directly from the production facility of one producer and observed a significant decrease (P < 0.01) in aerobic plate counts compared with the initial sampling. The observed difference between products purchased in stores compared with those collected directly from the factory suggests that poor temperature control during distribution and display in stores leads to reduced microbiological quality. Microbiological analysis of the sushi ingredients revealed that potentially pathogenic bacteria such as mesophilic Aeromonas spp. or bacteria belonging to the Enterobacteriaceae can be introduced into sushi through both raw vegetables and fish. The results highlight the importance of high quality ingredients and proper temperature control to ensure stable quality and safety of these food products.
de Freitas, Rosângela; Luiz, Lívia M Pinheiro; Alves, Maura Pinheiro; Valence-Bertel, Florence; Nero, Luís Augusto; de Carvalho, Antônio Fernandes
2013-08-01
Propionibacteria derived from dairy products are relevant starter cultures for the production of Swiss and Emmental-type cheeses, and the monitoring of which is mandatory for proper quality control. This study aimed to evaluate an alternative procedure to enumerate propionibacteria, in order to develop a reliable and practical methodology to be employed by dairy industries. 2,3,5-triphenyltetrazolium chloride (TTC) inhibitory activity was tested against five reference strains (CIRM 09, 38, 39, 40 and 116); TTC at 0·0025% (w/v) was not inhibitory, with the exception of one strain (CIRM 116). Subsequently, the four TTC-resistant strains, three commercial starter cultures (PS-1, PB-I, and CHOO) and twelve Emmental-type cheese samples were subjected to propionibacteria enumeration using Lithium Glycerol (LG) agar, and Petrifilm™ Aerobic Count (AC) plates added to LG broth (anaerobic incubation at 30 °C for 7 d). Petrifilm™ AC added to LG broth presented high counts than LG agar (P<0·05) for only two reference strains (CIRM 39, and 40) and for all commercial starter cultures. Cheese sample counts obtained by both procedures did not show significant differences (P<0·05). Significant correlation indexes were observed between the counts recorded by both methods (P<0·05). These results demonstrate the reliability of Petrifilm™ AC plates added to LG broth in enumerating select Propionibacterium spp., despite some limitations observed for specific commercial starter cultures.
Parthuisot, N.; Binet, M.; Touron-Bodilis, A.; Pougnard, C.; Lebaron, P.; Baudart, J.
2011-01-01
A new method was developed for the rapid and sensitive detection of viable Legionella pneumophila. The method combines specific immunofluorescence (IF) staining using monoclonal antibodies with a bacterial viability marker (ChemChrome V6 cellular esterase activity marker) by means of solid-phase cytometry (SPC). IF methods were applied to the detection and enumeration of both the total and viable L. pneumophila cells in water samples. The sensitivity of the IF methods coupled to SPC was 34 cells liter−1, and the reproducibility was good, with the coefficient of variation generally falling below 30%. IF methods were applied to the enumeration of total and viable L. pneumophila cells in 46 domestic hot water samples as well as in cooling tower water and natural water samples, such as thermal spring water and freshwater samples. Comparison with standard plate counts showed that (i) the total direct counts were always higher than the plate counts and (ii) the viable counts were higher than or close to the plate counts. With domestic hot waters, when the IF assay was combined with the viability test, SPC detected up to 3.4 × 103 viable but nonculturable L. pneumophila cells per liter. These direct IF methods could be a powerful tool for high-frequency monitoring of domestic hot waters or for investigating the occurrence of viable L. pneumophila in both man-made water systems and environmental water samples. PMID:21742913
NASA Astrophysics Data System (ADS)
Tremsin, A. S.; Vallerga, J. V.; McPhate, J. B.; Siegmund, O. H. W.
2015-07-01
Many high resolution event counting devices process one event at a time and cannot register simultaneous events. In this article a frame-based readout event counting detector consisting of a pair of Microchannel Plates and a quad Timepix readout is described. More than 104 simultaneous events can be detected with a spatial resolution of 55 μm, while >103 simultaneous events can be detected with <10 μm spatial resolution when event centroiding is implemented. The fast readout electronics is capable of processing >1200 frames/sec, while the global count rate of the detector can exceed 5×108 particles/s when no timing information on every particle is required. For the first generation Timepix readout, the timing resolution is limited by the Timepix clock to 10-20 ns. Optimization of the MCP gain, rear field voltage and Timepix threshold levels are crucial for the device performance and that is the main subject of this article. These devices can be very attractive for applications where the photon/electron/ion/neutron counting with high spatial and temporal resolution is required, such as energy resolved neutron imaging, Time of Flight experiments in lidar applications, experiments on photoelectron spectroscopy and many others.
APPARENT BIAS IN RIVER WATER INOCULUM FOLLOWING CENTRIFUGATION
We collected four measures of viable bacterial concentration (heterotrophic plate count, total coliform, fecal coliform, and Escherichia coli) and three measures of well color development in Biolog GN2 microtiter plates from water samples that were collected on two or three separ...
Hybrid Ion-Detector/Data-Acquisition System for a TOF-MS
NASA Technical Reports Server (NTRS)
Burton, William D., Jr.; Schultz, J. Albert; Vaughn, Valentine; McCully, Michael; Ulrich, Steven; Egan, Thomas F.
2006-01-01
A modified ion-detector/data-acquisition system has been devised to increase the dynamic range of a time-of-flight mass spectrometer (TOF-MS) that, previously, included a microchannel-plate detector and a data-acquisition system based on counting pulses and time-tagging them by use of a time-to-digital converter (TDC). The dynamic range of the TOF-MS was limited by saturation of the microchannel plate detector, which can handle no more than a few million counts per second. The modified system includes (1) a combined microchannel plate/discrete ion multiplier and (2) a hybrid data-acquisition system that simultaneously performs analog current or voltage measurements and multianode single-ion-pulse-counting time-of-flight measurements to extend the dynamic range of a TDC into the regime in which a mass peak comprises multiple ions arriving simultaneously at the detector. The multianode data are used to determine, in real time, whether the detector is saturated. When saturation is detected, the data-acquisition system selectively enables circuitry that simultaneously determines the ion-peak intensity by measuring the time profile of the analog current or voltage detector-output signal.
Detection of microbial concentration in ice-cream using the impedance technique.
Grossi, M; Lanzoni, M; Pompei, A; Lazzarini, R; Matteuzzi, D; Riccò, B
2008-06-15
The detection of microbial concentration, essential for safe and high quality food products, is traditionally made with the plate count technique, that is reliable, but also slow and not easily realized in the automatic form, as required for direct use in industrial machines. To this purpose, the method based on impedance measurements represents an attractive alternative since it can produce results in about 10h, instead of the 24-48h needed by standard plate counts and can be easily realized in automatic form. In this paper such a method has been experimentally studied in the case of ice-cream products. In particular, all main ice-cream compositions of real interest have been considered and no nutrient media has been used to dilute the samples. A measurement set-up has been realized using benchtop instruments for impedance measurements on samples whose bacteria concentration was independently measured by means of standard plate counts. The obtained results clearly indicate that impedance measurement represents a feasible and reliable technique to detect total microbial concentration in ice-cream, suitable to be implemented as an embedded system for industrial machines.
Borneman, Darand L; Ingham, Steve
2014-05-01
The objective of this study was to determine if a correlation exists between standard plate count (SPC) and somatic cell count (SCC) monthly reported results for Wisconsin dairy producers. Such a correlation may indicate that Wisconsin producers effectively controlling sanitation and milk temperature (reflected in low SPC) also have implemented good herd health management practices (reflected in low SCC). The SPC and SCC results for all grade A and B dairy producers who submitted results to the Wisconsin Department of Agriculture, Trade, and Consumer Protection, in each month of 2012 were analyzed. Grade A producer SPC results were less dispersed than grade B producer SPC results. Regression analysis showed a highly significant correlation between SPC and SCC, but the R(2) value was very small (0.02-0.03), suggesting that many other factors, besides SCC, influence SPC. Average SCC (across 12 mo) for grade A and B producers decreased with an increase in the number of monthly SPC results (out of 12) that were ≤ 25,000 cfu/mL. A chi-squared test of independence showed that the proportion of monthly SCC results >250,000 cells/mL varied significantly depending on whether the corresponding SPC result was ≤ 25,000 or >25,000 cfu/mL. This significant difference occurred in all months of 2012 for grade A and B producers. The results suggest that a generally consistent level of skill exists across dairy production practices affecting SPC and SCC. Copyright © 2014 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
Protocols and programs for high-throughput growth and aging phenotyping in yeast.
Jung, Paul P; Christian, Nils; Kay, Daniel P; Skupin, Alexander; Linster, Carole L
2015-01-01
In microorganisms, and more particularly in yeasts, a standard phenotyping approach consists in the analysis of fitness by growth rate determination in different conditions. One growth assay that combines high throughput with high resolution involves the generation of growth curves from 96-well plate microcultivations in thermostated and shaking plate readers. To push the throughput of this method to the next level, we have adapted it in this study to the use of 384-well plates. The values of the extracted growth parameters (lag time, doubling time and yield of biomass) correlated well between experiments carried out in 384-well plates as compared to 96-well plates or batch cultures, validating the higher-throughput approach for phenotypic screens. The method is not restricted to the use of the budding yeast Saccharomyces cerevisiae, as shown by consistent results for other species selected from the Hemiascomycete class. Furthermore, we used the 384-well plate microcultivations to develop and validate a higher-throughput assay for yeast Chronological Life Span (CLS), a parameter that is still commonly determined by a cumbersome method based on counting "Colony Forming Units". To accelerate analysis of the large datasets generated by the described growth and aging assays, we developed the freely available software tools GATHODE and CATHODE. These tools allow for semi-automatic determination of growth parameters and CLS behavior from typical plate reader output files. The described protocols and programs will increase the time- and cost-efficiency of a number of yeast-based systems genetics experiments as well as various types of screens.
Inter-operator variation in ELISPOT analysis of measles virus-specific IFN-gamma-secreting T cells.
Ryan, J E; Ovsyannikova, I G; Dhiman, N; Pinsky, N A; Vierkant, R A; Jacobson, R M; Poland, G A
2005-01-01
The ELISPOT assay is a highly sensitive technique used for the detection of individual cytokine releasing cells. We have developed an IFN-gamma ELISPOT assay utilizing unfractionated frozen peripheral blood mononuclear cells (PBMC) to quantify the frequency of measles virus (MV)-specific IFN-gamma-secreting T cells in 117 healthy children who had been previously immunized with two doses of the measles-mumps-rubella vaccine. We have also estimated the variability associated with the quantification of ELISPOT plates and compared the number of MV-specific IFN-gamma-secreting T cells for each subject as determined by two different operators of an ELISPOT reader. The median frequency of MV-specific IFN-gamma-producing memory T cells detected by this assay was 0.005 % and 0.01 % as determined by an in-house and commercial operator, respectively. Although we found a significant correlation (r = 0.83, p<0.0001) between the number of spots counted by the commercial and in-house operators of an ELISPOT reader, the median number of spots counted by the commercial operator was twice the number of spots counted by an in-house operator (p<0.001). This demonstrates the importance of using a common ELISPOT reader and operator, among other parameters, to quantify the number of spots when a large volume of plates are being scanned and analyzed.
Shultzaberger, Ryan K.; Paddock, Mark L.; Katsuki, Takeo; Greenspan, Ralph J.; Golden, Susan S.
2016-01-01
The temporal measurement of a bioluminescent reporter has proven to be one of the most powerful tools for characterizing circadian rhythms in the cyanobacterium Synechococcus elongatus. Primarily, two approaches have been used to automate this process: (1) detection of cell culture bioluminescence in 96-well plates by a photomultiplier tube-based plate-cycling luminometer (TopCount Microplate Scintillation and Luminescence Counter, Perkin Elmer) and (2) detection of individual colony bioluminescence by iteratively rotating a Petri dish under a cooled CCD camera using a computer-controlled turntable. Each approach has distinct advantages. The TopCount provides a more quantitative measurement of bioluminescence, enabling the direct comparison of clock output levels among strains. The computer-controlled turntable approach has a shorter set-up time and greater throughput, making it a more powerful phenotypic screening tool. While the latter approach is extremely useful, only a few labs have been able to build such an apparatus because of technical hurdles involved in coordinating and controlling both the camera and the turntable, and in processing the resulting images. This protocol provides instructions on how to construct, use, and process data from a computer-controlled turntable to measure the temporal changes in bioluminescence of individual cyanobacterial colonies. Furthermore, we describe how to prepare samples for use with the TopCount to minimize experimental noise, and generate meaningful quantitative measurements of clock output levels for advanced analysis. PMID:25662451
Protocol for evaluating the efficacy of cetylpyridinium chloride as a beef hide intervention.
Bosilevac, Joseph M; Wheeler, Tommy L; Rivera-Betancourt, Mildred; Nou, Xiangwu; Arthur, Terrance M; Shackelford, Steven D; Kent, Matthew P; Jaroni, Divya; Osborn, Matthew S; Rossman, Michelle; Reagan, James O; Koohmaraie, Mohammad
2004-02-01
The objective of this study was to establish the necessary protocols and assess the efficacy of cetylpyridinium chloride (CPC) as an antimicrobial intervention on beef cattle hides. Experiments using CPC were conducted to determine (i) the methods of neutralization needed to obtain valid efficacy measurements, (ii) the effect of concentration and dwell time after treatment, (iii) the effect of CPC on hide and carcass microbial populations when cattle were treated at a feedlot and then transported to a processing facility for harvest, and (iv) the effectiveness of spray pressure and two-spray combinations of CPC and water to reduce hide microbial populations. Residual CPC in hide sponge samples prevented bacterial growth. Dey-Engley neutralization media at 7.8% and a centrifugation step were necessary to overcome this problem. All dwell times, ranging from 30 s to 4 h, after 1% CPC application to cattle hides resulted in aerobic plate counts and Enterobacteriaceae counts 1.5 log CFU/100 cm2 lower than controls. The most effective dose of CPC was 1%, which reduced aerobic plate counts and Enterobacteriaceae counts 2 and 1 log CFU/100 cm2, respectively. Low-pressure application of 1% CPC at the feedlot, transport to the processing facility, and harvest within 5 h of application resulted in no effect on Escherichia coli O157 prevalence on hides or preevisceration carcasses. Two high-pressure CPC washes lowered aerobic plate counts and Enterobacteriaceae counts by 4 log CFU/100 cm2, and two medium-pressure CPC washes were only slightly less effective. These results indicate that under the proper conditions, CPC may still be effective for reducing microbial populations on cattle hides. Further study is warranted to determine if this effect will result in reduction of hide-to-carcass contamination during processing.
Champagne, C P; Raymond, Y; Gonthier, J; Audet, P
2009-04-01
Pasteurized and unfermented milks supplemented with probiotic bacteria are appearing on the market. It then becomes a challenge to ascertain the undesirable contamination microbiota in the presence of a largely superior population of probiotic bacteria. A method to enumerate the contaminating microbial microbiota in such probiotic-enriched milks was developed. The probiotic cultures, Lactobacillus rhamnosus Lb-Immuni-T and Bifidobacterium animalis subsp. lactis BB-12(R), were added to a pasteurized unfermented milk to reach a minimum of 1 billion CFU per 250 mL portion, as ascertained by plating on de Man - Rogosa - Sharpe (MRS) agar in anaerobic conditions. No growth of B. animalis subsp. lactis BB-12 was noted on plate count agar (PCA) or Petrifilm plates, and the presence of this culture did not affect standard plate counts (SPC) of contaminating bacteria. However, L. rhamnosus formed colonies on PCA and Petrifilm plates. Attempts were thus made to inhibit the growth of the probiotic lactobacilli in PCA. The addition of 2% sodium phosphate (SP) or 5% glycerophosphate (GP) inhibited the growth of the lactobacilli in broths, but pin-point colonies of L. rhamnosus Lb-Immuni-T nevertheless appeared on PCA supplemented with phosphates. SPC could be obtained on PCA + 2% SP by only counting the large colonies, but this resulted in a significant (4.4 fold) underestimation of SPC values. On Petrifilm AC, at dilutions 0 to 2, all colonies were considered as being contaminants, while at dilutions 3 and 4, only large colonies were counted for SPC determinations. There was a direct correlation (R2 = 0.99) between SPC values with Petrifilm in uninoculated milks and those obtained on probiotic-enriched milks. The high correlation obtained over the 102 to 106 CFU/mL range of SPC values show that this Petrifilm method is appropriate to evaluate the microbiological quality of pasteurized milks enriched with L. rhamnosus Lb-Immuni-T and B. animalis subsp. lactis BB-12.
Noise-free accurate count of microbial colonies by time-lapse shadow image analysis.
Ogawa, Hiroyuki; Nasu, Senshi; Takeshige, Motomu; Funabashi, Hisakage; Saito, Mikako; Matsuoka, Hideaki
2012-12-01
Microbial colonies in food matrices could be counted accurately by a novel noise-free method based on time-lapse shadow image analysis. An agar plate containing many clusters of microbial colonies and/or meat fragments was trans-illuminated to project their 2-dimensional (2D) shadow images on a color CCD camera. The 2D shadow images of every cluster distributed within a 3-mm thick agar layer were captured in focus simultaneously by means of a multiple focusing system, and were then converted to 3-dimensional (3D) shadow images. By time-lapse analysis of the 3D shadow images, it was determined whether each cluster comprised single or multiple colonies or a meat fragment. The analytical precision was high enough to be able to distinguish a microbial colony from a meat fragment, to recognize an oval image as two colonies contacting each other, and to detect microbial colonies hidden under a food fragment. The detection of hidden colonies is its outstanding performance in comparison with other systems. The present system attained accuracy for counting fewer than 5 colonies and is therefore of practical importance. Copyright © 2012 Elsevier B.V. All rights reserved.
Montei, Carolyn; McDougal, Susan; Mozola, Mark; Rice, Jennifer
2014-01-01
The Soleris Non-fermenting Total Viable Count method was previously validated for a wide variety of food products, including cocoa powder. A matrix extension study was conducted to validate the method for use with cocoa butter and cocoa liquor. Test samples included naturally contaminated cocoa liquor and cocoa butter inoculated with natural microbial flora derived from cocoa liquor. A probability of detection statistical model was used to compare Soleris results at multiple test thresholds (dilutions) with aerobic plate counts determined using the AOAC Official Method 966.23 dilution plating method. Results of the two methods were not statistically different at any dilution level in any of the three trials conducted. The Soleris method offers the advantage of results within 24 h, compared to the 48 h required by standard dilution plating methods.
Ahmad, S; Srivastava, P K
2007-04-01
Investigations were carried to study the effect of heart incorporation (0%, 15% and 20%) and increasing levels of fat (20% and 25%) on physicochemical (pH, moisture content and thiobarbituric acid, TBA number) and microbiological (total plate count and yeast and mold count) quality and shelf life of semi dry sausages of buffalo meat during refrigerated storage (4°C). Different levels of fat significantly (p<0.05) increased the pH of the sausage samples. However different levels of heart incorporation did not significantly (p<0.05) affect pH, moisture content and TBA number of sausage samples. Fresh samples had pH, moisture content and TBA number in the range of 5.15-5.28, 42.4-47.4% and 0.073-0.134 respectively. Refrigerated storage significantly (p<0.05) increased TBA number of control samples while storage did not significantly (p<0.05) increase the TBA number of sodium ascorbate (SA) treated samples. Total plate counts of twelve sausage samples were f under the TFTC (too few to count) limit at the initial stage. Incorporation of different levels of heart and also increasing levels of fat did not significantly (p<0.05) increase the log TPC/g values. Yeast and molds were not detected in twelve samples of semi dry fermented sausages in their fresh condition. Storage revealed that there was a consistent decrease in pH, and moisture content. Refrigerated storage significantly (p<0.05) reduced both pH and moisture contents. TBA number and total plate counts and yeast and mold counts of controls were found to increase significantly (p<0.05) during refrigerated storage. However, in SA treated sausage, only TPC and yeast and mold count significantly (p<0.05) increased during refrigerated storage. Shelf life of the sausages was found to be 60 days under refrigerated storage (4°C).
Hansen, Sarah J Z; Morovic, Wesley; DeMeules, Martha; Stahl, Buffy; Sindelar, Connie W
2018-01-01
The current standard for enumeration of probiotics to obtain colony forming units by plate counts has several drawbacks: long time to results, high variability and the inability to discern between bacterial strains. Accurate probiotic cell counts are important to confirm the delivery of a clinically documented dose for its associated health benefits. A method is described using chip-based digital PCR (cdPCR) to enumerate Bifidobacterium animalis subsp. lactis Bl-04 and Lactobacillus acidophilus NCFM both as single strains and in combination. Primers and probes were designed to differentiate the target strains against other strains of the same species using known single copy, genetic differences. The assay was optimized to include propidium monoazide pre-treatment to prevent amplification of DNA associated with dead probiotic cells as well as liberation of DNA from cells with intact membranes using bead beating. The resulting assay was able to successfully enumerate each strain whether alone or in multiplex. The cdPCR method had a 4 and 5% relative standard deviation (RSD) for Bl-04 and NCFM, respectively, making it more precise than plate counts with an industry accepted RSD of 15%. cdPCR has the potential to replace traditional plate counts because of its precision, strain specificity and the ability to obtain results in a matter of hours.
What's growing on your stethoscope? (And what you can do about it).
Schroeder, Ariel; Schroeder, Maryellen A; D'Amico, Frank
2009-08-01
Studies have shown that rubbing alcohol pads on stethoscope diaphragms can reduce bacterial colonization, but alcohol pads are used infrequently used and not always available. We conducted a prospective, single-blinded study to investigate whether simultaneously scrubbing hands and stethoscope head with alcohol-based hand foam would significantly reduce bacterial counts on the stethoscope. Using their own stethoscope, participants imprinted the stethoscope head onto a chocolate agar plate, then used alcohol-based hand foam to cleanse their hands while simultaneously rubbing the stethoscope head. Once the stethoscope heads were dry, the participants imprinted their stethoscope heads onto a second plate. After 48 hours' incubation, we determined the bacterial counts for the prewash and post-wash plates, and compared the 2. We analyzed a total of 184 cultures (from 92 stethoscopes). Both the mean (28 prewash vs 3 post-wash, P=.001) and median (11 prewash vs 1 post-wash, P=.001) colony counts were significantly greater before being cleansed. Three methicillin-resistant Staphylococcus aureus (MRSA) colonies were identified in the prewash period; all were destroyed by the foam. The estimated number of hand washes needed to prevent 1 MRSA colony is 31 (95% confidence interval [CI], 18-89). Simultaneously using hand foam to clean hands and stethoscope heads reduces bacterial counts on stethoscopes. Further research is needed to determine whether this intervention can reduce morbidity and mortality associated with bacterial infection.
Bacteriology of Dehydrated Space Foods 1
Powers, Edmund M.; Ay, Carl; El-Bisi, Hamed M.; Rowley, Durwood B.
1971-01-01
The initial bacteriological requirement established in 1964 for space foods by the U.S. Army Natick Laboratories are: a total aerobic plate count (≤ 10,000 per g), a total coliform count (≤ 10 per g), fecal coliforms (negative per gram), fecal streptococci (≤ 20 per g), coagulase-positive staphylococci (negative in 5 g) and salmonellae (negative in 10 g). Of the space foods and prototypes tested during 1968 and 1969, 93% complied with the total aerobic plate count, 98% had less than 1 coliform per g, and 99% were negative for fecal coliforms; 88% complied with the streptococci requirement; 100 and 98% were negative for staphylococci and salmonellae, respectively. Nineteen food samples which did not comply (as indicated parenthetically by actual counts per gram) with the requirements were (i) total aerobic plate count: beef soup and gravy base (18,000), chicken soup and gravy base (57,000), spaghetti with meat sauce (12,100 and 14,000), sugared coffee (> 300,000), chocolate ice cream cubes (20,000), and each of four samples of chocolate candy (12,000 to 61,000); (ii) coliforms: two out of three vanilla milk drinks (16 and 127) and one beef hash bar (14); (iii) fecal coliforms: one sample of chicken soup and gravy base positive; (iv) fecal streptococci: two samples of peanut cubes (40 and 108), coconut cubes (75), chicken soup and gravy base (2,650), beef soup and gravy base (33), and five out of six flavored milk drinks (23 to 300); (v) salmonellae: one each of chicken and beef soup and gravy base were positive. Images PMID:4940878
Formation and resuscitation of viable but nonculturable Salmonella typhi.
Zeng, Bin; Zhao, Guozhong; Cao, Xiaohong; Yang, Zhen; Wang, Chunling; Hou, Lihua
2013-01-01
Salmonella typhi is a pathogen that causes the human disease of typhoid fever. The aim of this study was to investigate the viable but nonculturable (VBNC) state of S. typhi. Some samples were stimulated at 4°C or -20°C, while others were induced by different concentrations of CuSO4. Total cell counts remained constant throughout several days by acridine orange direct counting; however, plate counts declined to undetectable levels within 48 hours by plate counting at -20°C. The direct viable counts remained fairly constant at this level by direct viable counting. Carbon and nitrogen materials slowly decreased which indicated that a large population of cells existed in the VBNC state and entered the VBNC state in response to exposure to 0.01 or 0.015 mmol/L CuSO4 for more than 14 or 12 days, respectively. Adding 3% Tween 20 or 1% catalase enabled cells to become culturable again, with resuscitation times of 48 h and 24 h, respectively. The atomic force microscope results showed that cells gradually changed in shape from short rods to coccoids, and decreased in size when they entered the VBNC state. Further animal experiments suggested that resuscitated cells might regain pathogenicity.
Rapid enumeration of low numbers of moulds in tea based drinks using an automated system.
Tanaka, Kouichi; Yamaguchi, Nobuyasu; Baba, Takashi; Amano, Norihide; Nasu, Masao
2011-01-31
Aseptically prepared cold drinks based on tea have become popular worldwide. Contamination of these drinks with harmful microbes is a potential health problem because such drinks are kept free from preservatives to maximize aroma and flavour. Heat-tolerant conidia and ascospores of fungi can survive pasteurization, and need to be detected as quickly as possible. We were able to rapidly and accurately detect low numbers of conidia and ascospores in tea-based drinks using fluorescent staining followed by an automated counting system. Conidia or ascospores were inoculated into green tea and oolong tea, and samples were immediately filtered through nitrocellulose membranes (pore size: 0.8 μm) to concentrate fungal propagules. These were transferred onto potato dextrose agar and incubated for 23 h at 28 °C. Fungi germinating on the membranes were fluorescently stained for 30 min. The stained mycelia were counted selectively within 90s using an automated counting system (MGS-10LD; Chuo Electric Works, Osaka, Japan). Very low numbers (1 CFU/100ml) of conidia or ascospores could be rapidly counted, in contrast to traditional labour intensive techniques. All tested mould strains were detected within 24h while conventional plate counting required 72 h for colony enumeration. Counts of slow-growing fungi (Cladosporium cladosporioides) obtained by automated counting and by conventional plate counting were close (r(2) = 0.986). Our combination of methods enables counting of both fast- and slow-growing fungi, and should be useful for microbiological quality control of tea-based and also other drinks. Copyright © 2011 Elsevier B.V. All rights reserved.
De Prijck, K; Peeters, E; Nelis, H J
2008-12-01
To compare the survival of four bacterial strains (Escherichia coli, Proteus mirabilis, Staphylococcus aureus, Pseudomonas aeruginosa) in pharmaceutical oils, including jojoba oil/tea tree oil, carbol oil, jojoba oil and sesame oil. Oils were spiked with the test bacteria in a concentration of 10(4) CFU ml(-1). Bacteria were extracted from oils with phosphate-buffered saline containing 0.5% Tween 20. Aliquots of the pooled water layers were analysed by solid-phase cytometry and plate counting. Plate counts dropped to zero for all test strains exposed for 24 h to three of the four oils. In contrast, significant numbers of viable cells were still detected by SPC, except in the jojoba oil/tea tree oil mixture and partly in sesame oil. Exposure of bacteria for 24 h to the two oils containing an antimicrobial led to a loss of their culturability but not necessarily of their viability. The antibacterial activity of the jojoba oil/tea tree oil mixture supersedes that of carbol oil. These in vitro data suggest that the jojoba oil/tea tree oil mixture more than carbol oil inhibits bacterial proliferation when used for intermittent self-catherization.
Stachelska, Milena A
2017-12-04
The aim of this paper was to detect Lactobacillus delbrueckii and Streptococcus thermophilus using real-time quantitative PCR assay in 7-day ripening cheese produced from unpasteurised milk. Real-time quantitative PCR assays were designed to identify and enumerate the chosen species of lactic acid bacteria (LAB) in ripened cheese. The results of molecular quantification and classic bacterial enumeration showed a high level of similarity proving that DNA extraction was carried out in a proper way and that genomic DNA solutions were free of PCR inhibitors. These methods revealed the presence of L. delbrueckii and S. thermophilus. The real-time PCR enabled quantification with a detection of 101-103 CFU/g of product. qPCR-standard curves were linear over seven log units down to 101 copies per reaction; efficiencies ranged from 77.9% to 93.6%. Cheese samples were analysed with plate count method and qPCR in parallel. Compared with the classic plate count method, the newly developed qPCR method provided faster and species specific identification of two dairy LAB and yielded comparable quantitative results.
Comparison of Primary Models to Predict Microbial Growth by the Plate Count and Absorbance Methods.
Pla, María-Leonor; Oltra, Sandra; Esteban, María-Dolores; Andreu, Santiago; Palop, Alfredo
2015-01-01
The selection of a primary model to describe microbial growth in predictive food microbiology often appears to be subjective. The objective of this research was to check the performance of different mathematical models in predicting growth parameters, both by absorbance and plate count methods. For this purpose, growth curves of three different microorganisms (Bacillus cereus, Listeria monocytogenes, and Escherichia coli) grown under the same conditions, but with different initial concentrations each, were analysed. When measuring the microbial growth of each microorganism by optical density, almost all models provided quite high goodness of fit (r(2) > 0.93) for all growth curves. The growth rate remained approximately constant for all growth curves of each microorganism, when considering one growth model, but differences were found among models. Three-phase linear model provided the lowest variation for growth rate values for all three microorganisms. Baranyi model gave a variation marginally higher, despite a much better overall fitting. When measuring the microbial growth by plate count, similar results were obtained. These results provide insight into predictive microbiology and will help food microbiologists and researchers to choose the proper primary growth predictive model.
Van Nevel, S; Koetzsch, S; Proctor, C R; Besmer, M D; Prest, E I; Vrouwenvelder, J S; Knezev, A; Boon, N; Hammes, F
2017-04-15
Drinking water utilities and researchers continue to rely on the century-old heterotrophic plate counts (HPC) method for routine assessment of general microbiological water quality. Bacterial cell counting with flow cytometry (FCM) is one of a number of alternative methods that challenge this status quo and provide an opportunity for improved water quality monitoring. After more than a decade of application in drinking water research, FCM methodology is optimised and established for routine application, supported by a considerable amount of data from multiple full-scale studies. Bacterial cell concentrations obtained by FCM enable quantification of the entire bacterial community instead of the minute fraction of cultivable bacteria detected with HPC (typically < 1% of all bacteria). FCM measurements are reproducible with relative standard deviations below 3% and can be available within 15 min of samples arriving in the laboratory. High throughput sample processing and complete automation are feasible and FCM analysis is arguably less expensive than HPC when measuring more than 15 water samples per day, depending on the laboratory and selected staining procedure(s). Moreover, many studies have shown FCM total (TCC) and intact (ICC) cell concentrations to be reliable and robust process variables, responsive to changes in the bacterial abundance and relevant for characterising and monitoring drinking water treatment and distribution systems. The purpose of this critical review is to initiate a constructive discussion on whether FCM could replace HPC in routine water quality monitoring. We argue that FCM provides a faster, more descriptive and more representative quantification of bacterial abundance in drinking water. Copyright © 2017 Elsevier Ltd. All rights reserved.
Nurses’ uniforms: How many bacteria do they carry after one shift?
Sanon, Marie-Anne; Watkins, Sally
2013-01-01
This pilot study investigated the pathogens that nurses are potentially bringing into the public and their home when they wear work uniforms outside of the work environment. To achieve this, sterilized uniforms were distributed to 10 nurses at a local hospital in Washington State at the beginning of their shift. Worn uniforms were collected at the end of the shifts and sent to a laboratory for analysis. Four tests were conducted: 1) a heterotrophic growth plate count, 2) methicillin-resistant Staphylococcus aureus (MRSA) growth, 3) vancomycin-resistant Enterococci (VRE), and 4) identification of the heterotrophic plate counts. Each participant completed a questionnaire and a survey. The results showed that the average bacteria colony growth per square inch was 1,246 and 5,795 for day and night shift, respectively. After 48 h, MRSA positives were present on 4 of the day shift and 3 of the night shift uniforms. Additional bacteria identified include: Bacillus sp., Micrococcus luteus, Staphylococcus aureus, Staphylococcus epidermidis, and Micrococcus roseus. The significant presence of bacteria on the uniforms 48 h after the shift ended necessitates further study, discussions and policy consideration regarding wearing health care uniforms outside of the work environment. PMID:25285235
Nurses' uniforms: How many bacteria do they carry after one shift?
Sanon, Marie-Anne; Watkins, Sally
2012-12-01
This pilot study investigated the pathogens that nurses are potentially bringing into the public and their home when they wear work uniforms outside of the work environment. To achieve this, sterilized uniforms were distributed to 10 nurses at a local hospital in Washington State at the beginning of their shift. Worn uniforms were collected at the end of the shifts and sent to a laboratory for analysis. Four tests were conducted: 1) a heterotrophic growth plate count, 2) methicillin-resistant Staphylococcus aureus (MRSA) growth, 3) vancomycin-resistant Enterococci (VRE), and 4) identification of the heterotrophic plate counts. Each participant completed a questionnaire and a survey. The results showed that the average bacteria colony growth per square inch was 1,246 and 5,795 for day and night shift, respectively. After 48 h, MRSA positives were present on 4 of the day shift and 3 of the night shift uniforms. Additional bacteria identified include: Bacillus sp., Micrococcus luteus, Staphylococcus aureus, Staphylococcus epidermidis, and Micrococcus roseus. The significant presence of bacteria on the uniforms 48 h after the shift ended necessitates further study, discussions and policy consideration regarding wearing health care uniforms outside of the work environment.
Microbiological Quality Assessment of Game Meats at Retail in Japan.
Asakura, Hiroshi; Kawase, Jun; Ikeda, Tetsuya; Honda, Mioko; Sasaki, Yoshimasa; Uema, Masashi; Kabeya, Hidenori; Sugiyama, Hiromu; Igimi, Shizunobu; Takai, Shinji
2017-12-01
In this study, we examined the prevalence of Shiga toxin-producing Escherichia coli and Salmonella spp. and the distribution of indicator bacteria in 248 samples of game meats (120 venison and 128 wild boar) retailed between November 2015 and March 2016 in Japan. No Salmonella spp. were detected in any of the samples, whereas Shiga toxin-producing Escherichia coli serotype OUT:H25 (stx 2d + , eae - ) was isolated from one deer meat sample, suggesting a possible source for human infection. Plate count assays indicated greater prevalence of coliforms and E. coli in wild boar meat than in venison, whereas their prevalence in processing facilities showed greater variation than in animal species. The 16S rRNA ion semiconductor sequencing analysis of 24 representative samples revealed that the abundances of Acinetobacter and Arthrobacter spp. significantly correlated with the prevalence of E. coli, and quantitative PCR analyses in combination with selective plate count assay verified these correlations. To our knowledge, this is the first report to characterize the diversity of microorganisms of game meats at retail in Japan, together with identification of dominant microbiota. Our data suggest the necessity of bottom-up hygienic assessment in areas of slaughtering and processing facilities to improve microbiological safety.
Lee, Eun Gyung; Nelson, John H.; Kashon, Michael L.; Harper, Martin
2015-01-01
A Japanese round-robin study revealed that analysts who used a dark-medium (DM) objective lens reported higher fiber counts from American Industrial Hygiene Association (AIHA) Proficiency Analytical Testing (PAT) chrysotile samples than those using a standard objective lens, but the cause of this difference was not investigated at that time. The purpose of this study is to determine any major source of this difference by performing two sets of round-robin studies. For the first round-robin study, 15 AIHA PAT samples (five each of chrysotile and amosite generated by water-suspended method, and five chrysotile generated by aerosolization method) were prepared with relocatable cover slips and examined by nine laboratories. A second round-robin study was then performed with six chrysotile field sample slides by six out of nine laboratories who participated in the first round-robin study. In addition, two phase-shift test slides to check analysts’ visibility and an eight-form diatom test plate to compare resolution between the two objectives were examined. For the AIHA PAT chrysotile reference slides, use of the DM objective resulted in consistently higher fiber counts (1.45 times for all data) than the standard objective (P-value < 0.05), regardless of the filter generation (water-suspension or aerosol) method. For the AIHA PAT amosite reference and chrysotile field sample slides, the fiber counts between the two objectives were not significantly different. No statistically significant differences were observed in the visibility of blocks of the test slides between the two objectives. Also, the DM and standard objectives showed no pattern of differences in viewing the fine lines and/or dots of each species images on the eight-form diatom test plate. Among various potential factors that might affect the analysts’ performance of fiber counts, this study supports the greater contrast caused by the different phase plate absorptions as the main cause of high counts for the AIHA PAT chrysotile slides using the DM objective. The comparison of fiber count ratios (DM/standard) between the AIHA PAT chrysotile samples and chrysotile field samples indicates that there is a fraction of fibers in the PAT samples approaching the theoretical limit of visibility of the phase-contrast microscope with 3-degree phase-shift. These fibers become more clearly visible through the greater contrast from the phase plate absorption of the DM objective. However, as such fibers are not present in field samples, no difference in counts between the two objectives was observed in this study. The DM objective, therefore, could be allowed for routine fiber counting as it will maintain continuity with risk assessments based on earlier phase-contrast microscopy fiber counts from field samples. Published standard methods would need to be modified to allow a higher aperture specification for the objective. PMID:25737333
Di Schiavi, Maria Teresa; Foti, Marina; Mosconi, Maria Cristina; Mattiolo, Giuseppina; Cavallina, Roberta
2014-01-01
Irradiation is a preservation technology used to improve the safety and hygienic quality of food. Aim of this study was to assess the applicability and validity of the microbiological screening method direct epifluorescence filter technique (DEFT)/aerobic plate count (APC) (EN 13783:2001) for the identification of irradiated herbs and spices. Tests on non-irradiated and irradiated samples of dried herbs and spices were performed. The method was based on the comparison of APC and count obtained using DEFT. In accordance with the standard reference, this method is not applicable to samples with APC<103 colony forming units (CFU)/g and this is its main limit. The results obtained in our laboratories showed that in 50% of cases of non-irradiated samples and in 96% of the samples treated with ionising radiation, the method was not applicable due to a value of CFU/g <103. PMID:27800348
Airborne Salmonella and Listeria associated with Irish commercial beef, sheep and pig plants.
Okraszewska-Lasica, Wioletta; Bolton, D J; Sheridan, J J; McDowell, D A
2014-06-01
Air samples from lairage, hide/fleece pulling or dehairing/scraping, evisceration and chilling areas in commercial beef, sheep and pig plants were examined for Salmonella spp. and Listeria monocytogenes, by impaction or sedimentation onto selective (Brilliant Green Agar, BSA; Listeria Selective Agar, LSA) and non-selective (Plate Count Agar, PCA) media. Both pathogens were frequently detected in all three plants. Improved recoveries were achieved by combining sedimentation, and broth based resuscitation, suggesting cell injury. Salmonella were recovered from all three plants, with the highest counts on BGA in the pig plant. The most common serotypes were S. Typhimurium in the beef/sheep plants and S. Derby in the pig plant. Very low counts of L. monocytogenes (e.g. 2.6CFUm(2)) were detected at hide removal on LSA sedimentation plates in the beef plant. These included serogroup 1/2a-3a and 1/2b-3b-7. Pathogen counts in the three plants were generally very low, suggesting that air is unlikely to be a significant source of carcass or plant surface contamination. Copyright © 2014 Elsevier Ltd. All rights reserved.
NASA Technical Reports Server (NTRS)
Munroe, J.; Wilkins, K.; Gruber, M.; Domack, Marcia S. (Technical Monitor)
2000-01-01
The Integral Airframe Structures (IAS) program investigated the feasibility of using "integrally stiffened" construction for commercial transport fuselage structure. The objective of the program was to demonstrate structural performance and weight equal to current "built-up" structure with lower manufacturing cost. Testing evaluated mechanical properties, structural details, joint performance, repair, static compression, and two-bay crack residual strength panels. Alloys evaluated included 7050-T7451 plate, 7050-T74511 extrusion, 6013-T6511x extrusion, and 7475-T7351 plate. Structural performance was evaluated with a large 7475-T7351 pressure test that included the arrest of a two-bay longitudinal crack, and a measure of residual strength for a two-bay crack centered on a broken frame. Analysis predictions for the two-bay longitudinal crack panel correlated well with the test results. Analysis activity conducted by the IAS team strongly indicates that current analysis tools predict integral structural behavior as accurately as built-up structure. The cost study results indicated that, compared to built-up fabrication methods, high-speed machining structure from aluminum plate would yield a recurring cost savings of 61%. Part count dropped from 78 individual parts on a baseline panel to just 7 parts for machined IAS structure.
Majeed, Muhammed; Majeed, Shaheen; Nagabhushanam, Kalyanam; Punnapuzha, Ardra; Philip, Sheena; Mundkur, Lakshmi
2018-01-01
Accurate enumeration of bacterial count in probiotic formulation is imperative to ensure that the product adheres to regulatory standards and citation in consumer product label. Standard methods like plate count, can enumerate only replicating bacterial population under selected culture conditions. Viable but non culturable bacteria (VBNC) retain characteristics of living cells and can regain cultivability by a process known as resuscitation. This is a protective mechanism adapted by bacteria to evade stressful environmental conditions. B. coagulans MTCC 5856(LactoSpore®) is a probiotic endospore which can survive for decades in hostile environments without dividing. In the present study, we explored the use of flow cytometry to enumerate the viable count of B. coagulans MTCC 5856 under acidic and alkaline conditions, high temperature and in commercial formulations like compressed tablets and capsules. Flow cytometry (FCM) was comparable to plate count method when the spores were counted at physiological conditions. We show that VBNC state is induced in B. coagulans MTCC 5856by high temperature and acidic pH. The cells get resuscitated under physiological conditions and FCM was sensitive to detect the VBNC spores. Flow cytometry showed excellent ability to assess the viable spore count in commercial probiotic formulations of B. coagulans MTCC 5856. The results establish Flow cytometry as a reliable method to count viable bacteria in commercial probiotic preparations. Sporulation as well as existence as VBNC could contribute to the extreme stability of B. coagulans MTCC 5856.
Majeed, Muhammed; Majeed, Shaheen; Nagabhushanam, Kalyanam; Punnapuzha, Ardra; Philip, Sheena
2018-01-01
Accurate enumeration of bacterial count in probiotic formulation is imperative to ensure that the product adheres to regulatory standards and citation in consumer product label. Standard methods like plate count, can enumerate only replicating bacterial population under selected culture conditions. Viable but non culturable bacteria (VBNC) retain characteristics of living cells and can regain cultivability by a process known as resuscitation. This is a protective mechanism adapted by bacteria to evade stressful environmental conditions. B. coagulans MTCC 5856(LactoSpore®) is a probiotic endospore which can survive for decades in hostile environments without dividing. In the present study, we explored the use of flow cytometry to enumerate the viable count of B. coagulans MTCC 5856 under acidic and alkaline conditions, high temperature and in commercial formulations like compressed tablets and capsules. Flow cytometry (FCM) was comparable to plate count method when the spores were counted at physiological conditions. We show that VBNC state is induced in B. coagulans MTCC 5856by high temperature and acidic pH. The cells get resuscitated under physiological conditions and FCM was sensitive to detect the VBNC spores. Flow cytometry showed excellent ability to assess the viable spore count in commercial probiotic formulations of B. coagulans MTCC 5856. The results establish Flow cytometry as a reliable method to count viable bacteria in commercial probiotic preparations. Sporulation as well as existence as VBNC could contribute to the extreme stability of B. coagulans MTCC 5856. PMID:29474436
Fu, Xin; Huang, Kelong; Liu, Suqin
2010-02-01
In this paper, a rapid, simple, and sensitive method was described for detection of the total bacterial count using SiO(2)-coated CdSe/ZnS quantum dots (QDs) as a fluorescence marker that covalently coupled with bacteria using glutaraldehyde as the crosslinker. Highly luminescent CdSe/ZnS were prepared by applying cadmium oxide and zinc stearate as precursors instead of pyrophoric organometallic precursors. A reverse-microemulsion technique was used to synthesize CdSe/ZnS/SiO(2) composite nanoparticles with a SiO(2) surface coating. Our results showed that CdSe/ZnS/SiO(2) composite nanoparticles prepared with this method possessed highly luminescent, biologically functional, and monodispersive characteristics, and could successfully be covalently conjugated with the bacteria. As a demonstration, it was found that the method had higher sensitivity and could count bacteria in 3 x 10(2) CFU/mL, lower than the conventional plate counting and organic dye-based method. A linear relationship of the fluorescence peak intensity (Y) and the total bacterial count (X) was established in the range of 3 x 10(2)-10(7) CFU/mL using the equation Y = 374.82X-938.27 (R = 0.99574). The results of the determination for the total count of bacteria in seven real samples were identical with the conventional plate count method, and the standard deviation was satisfactory.
Biofilms associated with poultry processing equipment.
Lindsay, D; Geornaras, I; von Holy, A
1996-01-01
Aerobic and Gram-negative bacteria were enumerated on non-metallic surfaces and stainless steel test pieces attached to equipment surfaces by swabbing and a mechanical dislodging procedure, respectively, in a South African grade B poultry processing plant. Changes in bacterial numbers were also monitored over time on metal test pieces. The highest bacterial counts were obtained from non-metallic surfaces such as rubber fingered pluckers and plastic defeathering curtains which exceeded the highest counts found on the metal surfaces by at least 1 log CFU cm-2. Gram-negative bacterial counts on all non-metallic surface types were at least 2 log CFU cm-2 lower than corresponding aerobic plate counts. On metal surfaces, the highest microbial numbers were obtained after 14 days exposure, with aerobic plate counts ranging from 3.57 log CFU cm-2 to 5.13 log CFU cm-2, and Gram-negative counts from 0.70 log CFU cm-2 to 3.31 log CFU cm-2. Scanning electron microscopy confirmed the presence of bacterial cells on non-metallic and metallic surfaces associated with poultry processing. Rubber 'fingers', plastic curtains, conveyor belt material and stainless steel test surfaces placed on the scald tank overflow and several chutes revealed extensive and often confluent bacterial biofilms. Extracellular polymeric substances, but few bacterial cells were visible on test pieces placed on evisceration equipment, spinchiller blades and the spinchiller outlet.
Effectiveness of a steam cleaning unit for disinfection in a veterinary hospital.
Wood, Cheryl L; Tanner, Benjamin D; Higgins, Laura A; Dennis, Jeffrey S; Luempert, Louis G
2014-12-01
To evaluate whether the application of steam to a variety of surface types in a veterinary hospital would effectively reduce the number of bacteria. 5 surface types. Steam was applied as a surface treatment for disinfection to 18 test sites of 5 surface types in a veterinary hospital. A pretreatment sample was obtained by collection of a swab specimen from the left side of each defined test surface. Steam disinfection was performed on the right side of each test surface, and a posttreatment sample was then collected in the same manner from the treated (right) side of each test surface. Total bacteria for pretreatment and posttreatment samples were quantified by heterotrophic plate counts and for Staphylococcus aureus, Pseudomonas spp, and total coliforms by counts on selective media. Significant reductions were observed in heterotrophic plate counts after steam application to dog runs and dog kennel floors. A significant reduction in counts of Pseudomonas spp was observed after steam application to tub sinks. Bacterial counts were reduced, but not significantly, on most other test surfaces that had adequate pretreatment counts for quantification. Development of health-care-associated infections is of increasing concern in human and veterinary medicine. The application of steam significantly reduced bacterial numbers on a variety of surfaces within a veterinary facility. Steam disinfection may prove to be an alternative or adjunct to chemical disinfection within veterinary practices.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wiggins, B. B.; Richardson, E.; Siwal, D.
A method for achieving good position resolution of low-intensity electron signals using a microchannel plate resistive anode detector is demonstrated. Electron events at a rate of 7 counts s{sup −1} are detected using a Z-stack microchannel plate. The dependence of position resolution on both the distance and the potential difference between the microchannel plate and resistive anode is investigated. Using standard commercial electronics, a measured position resolution of 170 μm (FWHM) is obtained, which corresponds to an intrinsic resolution of 157 μm (FWHM)
Two-dimensional photon-counting detector arrays based on microchannel array plates
NASA Technical Reports Server (NTRS)
Timothy, J. G.; Bybee, R. L.
1975-01-01
The production of simple and rugged photon-counting detector arrays has been made possible by recent improvements in the performance of the microchannel array plate (MCP) and by the parallel development of compatible electronic readout systems. The construction of proximity-focused MCP arrays of novel design in which photometric information from (n x m) picture elements is read out with a total of (n + m) amplifier and discriminator circuits is described. Results obtained with a breadboard (32 x 32)-element array employing 64 charge-sensitive amplifiers are presented, and the application of systems of this type in spectrometers and cameras for use with ground-based telescopes and on orbiting spacecraft discussed.
Microchannel plate life testing for UV spectroscopy instruments
NASA Astrophysics Data System (ADS)
Darling, N. T.; Siegmund, O. H. W.; Curtis, T.; McPhate, J.; Tedesco, J.; Courtade, S.; Holsclaw, G.; Hoskins, A.; Al Dhafri, S.
2017-08-01
The Emirates Mars Mission (EMM) UV Spectrograph (EMUS) is a far ultraviolet (102 nm to 170 nm) imaging spectrograph for characterization of the Martian exosphere and thermosphere. Imaging is accomplished by a photon counting open-face microchannel plate (MCP) detector using a cross delay line (XDL) readout. An MCP gain stabilization ("scrub") followed by lifetime spectral line burn-in simulation has been completed on a bare MCP detector at SSL. Gain and sensitivity stability of better than 7% has been demonstrated for total dose of 2.5 × 1012 photons cm-2 (2 C · cm-2 ) at 5.5 kHz mm-2 counting rates, validating the efficacy of an initial low gain full-field scrub.
McCray, Sally; Maunder, Kirsty; Krikowa, Renee; MacKenzie-Shalders, Kristen
2018-02-01
Room service is a foodservice model that has been increasingly implemented across health care facilities in an effort to improve patient satisfaction and reduce food waste. In 2013, Mater Private Hospital Brisbane, Australia, was the first hospital in Australia to implement room service, with the aim of improving patient nutrition care and reducing costs. The aim of this study was to comprehensively evaluate the nutritional intake, plate waste, patient satisfaction, and patient meal costs of room service compared to a traditional foodservice model. A retrospective analysis of quality-assurance data audits was undertaken to assess patient nutritional intake between a facility utilizing a traditional foodservice model and a facility utilizing room service and in a pre-post study design to assess plate waste, patient satisfaction, and patient meal costs before and after the room service implementation. Audit data were collected for eligible adult inpatients in Mater Private Hospital Brisbane and Mater Hospital Brisbane, Australia, between July 2012 and May 2015. The primary outcome measures were nutritional intake, plate waste, patient satisfaction, and patient meal costs. Independent samples t-tests and χ 2 analyses were conducted between pre and post data for continuous data and categorical data, respectively. Pearson χ 2 analysis of count data for sex and reasons for plate waste for data with counts more than five was used to determine asymptotic (two-sided) significance and n-1 χ 2 used for the plate waste analysis. Significance was assessed at P<0.05. This study reported an increased nutritional intake, improved patient satisfaction, and reduced plate waste and patient meal costs with room service compared to a traditional foodservice model. Comparison of nutritional intake between a traditional foodservice model (n=85) and room service (n=63) showed statistically significant increases with room service in both energy (1,306 kcal/day vs 1,588 kcal/day; P=0.005) and protein (52 g/day vs 66 g/day, P=0.003) intake, as well as energy and protein intake as a percentage of requirements (63% vs 75%; P=0.024 and 65% vs 85%; P=0.011, respectively). Total mean plate waste decreased from 29% (traditional foodservice model) to 12% (room service) (P<0.001). Patient satisfaction ratings indicated improvement with room service across all Press Ganey meal scores: 68th to 86th percentile overall; 64th to 95th percentile for "quality of food"; and 60th to 99th percentile for "flavor of food." Evaluated during comparable times of the year, patient meal costs decreased by 15% with room service. A patient-centered foodservice model, such as room service, can improve patient nutritional intake and enhance patient satisfaction in a budget constrained health care environment. Copyright © 2018 Academy of Nutrition and Dietetics. Published by Elsevier Inc. All rights reserved.
High-Throughput Quantification of Bacterial-Cell Interactions Using Virtual Colony Counts
Hoffmann, Stefanie; Walter, Steffi; Blume, Anne-Kathrin; Fuchs, Stephan; Schmidt, Christiane; Scholz, Annemarie; Gerlach, Roman G.
2018-01-01
The quantification of bacteria in cell culture infection models is of paramount importance for the characterization of host-pathogen interactions and pathogenicity factors involved. The standard to enumerate bacteria in these assays is plating of a dilution series on solid agar and counting of the resulting colony forming units (CFU). In contrast, the virtual colony count (VCC) method is a high-throughput compatible alternative with minimized manual input. Based on the recording of quantitative growth kinetics, VCC relates the time to reach a given absorbance threshold to the initial cell count using a series of calibration curves. Here, we adapted the VCC method using the model organism Salmonella enterica sv. Typhimurium (S. Typhimurium) in combination with established cell culture-based infection models. For HeLa infections, a direct side-by-side comparison showed a good correlation of VCC with CFU counting after plating. For MDCK cells and RAW macrophages we found that VCC reproduced the expected phenotypes of different S. Typhimurium mutants. Furthermore, we demonstrated the use of VCC to test the inhibition of Salmonella invasion by the probiotic E. coli strain Nissle 1917. Taken together, VCC provides a flexible, label-free, automation-compatible methodology to quantify bacteria in in vitro infection assays. PMID:29497603
Track counts as indices to abundances of arboreal rodents.
A.B. Carey; J.W. Witt
1991-01-01
Counting tracks to obtain an index of abundance for species difficult to capture offers a promise of efficiency and effectiveness when broad surveys of populations are necessary. Sand plots, smoked kymograph paper, and, recently, smoked aluminum plates have been used to record tracks(Raphael et al., 1986; Taylor and Raphael, 1988). Findings of studies of carnivores...
NASA Astrophysics Data System (ADS)
Yanbe, Yutaka; Sato, Eiichi; Chiba, Hiraku; Maeda, Tomoko; Matsushita, Ryo; Oda, Yasuyuki; Hagiwara, Osahiko; Matsukiyo, Hiroshi; Osawa, Akihiro; Enomoto, Toshiyuki; Watanabe, Manabu; Kusachi, Shinya; Sato, Shigehiro; Ogawa, Akira
2013-09-01
X-ray fluorescence (XRF) analysis is useful for mapping various atoms in objects. Bremsstrahlung X-rays with energies beyond tantalum (Ta) K-edge energy 67.4 keV are absorbed effectively using a 100-µm-thick Ta filter, and the filtered X-rays including tungsten (W) Kα rays are absorbed by gadolinium (Gd) atoms in objects. The Gd XRF is then produced from Gd atoms in the objects and is counted by a cadmium telluride (CdTe) detector. Gd Kα photons with a maximum count rate of 1 kilo counts per second are dispersed using a multichannel analyzer, and the number of photons is counted by a counter card. The distance between the CdTe detector and the object is minimized to 40 mm to increase the count rate. The object is scanned using an x-y stage with a velocity of 5.0 mm/s, and Gd mapping are shown on a computer monitor. The scan steps of the x- and y-axes were both 2.5 mm, and the photon-counting time per mapping point was 0.5 s. We obtained Gd XRF images at high contrast, and Gd Kα photons were easily detected from cancerous regions in a nude mouse placed behind a 20-mm-thick poly(methyl methacrylate) plate.
von Breymann, Juliana; Chaves, Carolina; Arias, María Laura
2013-03-01
The objective of this work was to determine some of the indicators associated to shelf life, hygiene, process and storage conditions for some of custard apple, mango and passion fruit pulps distributed by the main supermarket chains of the Metropolitan Area of San José, Costa Rica, as well as to examine the potential presence of Listeria monocytogenes in them. Sixty fruit pulp samples were analyzed. Tests included pH determination, total aerobic plate count, yeasts and mold count, lactic bacteria count, total and fecal most probable number and the presence/absence of Listeria monocytogenes in 25 g of the product. Fruit pulp's pH ranged between 3,1 and 3,9, and the microbiological counts obtained were relatively low except for one industry. None of the samples analyzed presented total or fecal coliforms. The presence of Listeria monocytogenes was confirmed in three samples, all of them coming from industry C. Low microbiological counts obtained may be due to the addition of preserving substances and to the pasteurization of some of the products; lack of these two elements may allow the presence of dangerous bacteria such as Listeria monocytogenes.
2014-12-11
and 1 mm depth. Bacterial culture and cell count determination Bacterial species of Acinetobacter baumannii (A. baumannii, ST-3), Escherichia coli...remove all broth components followed by a final resuspension of the pellet in ddH2O back to 1 OD. Cell count was determined by plating the 10 4 , 10 3...10 2 and 10 1 cell dilutions on TSB Nutrient Agar media. Colony forming units (CFU) were counted the following day to confirm bacterial species
An evidential example of airborne bacteria in a crowded, underground public concourse in Tokyo
NASA Astrophysics Data System (ADS)
Seino, Kaoruko; Takano, Takehito; Nakamura, Keiko; Watanabe, Masafumi
2005-01-01
We examined airborne bacteria in an underground concourse in Tokyo and investigated conditions that influenced bacterial counts. Airborne bacteria were collected by using an impactor sampler. Colonies on plate count agar (PCA) and Columbia colistin-nalidixic acid agar with 5% sheep blood (CNA agar) were enumerated. The range, geometric mean, and 95% CI of the bacterial counts (CFU m-3) on PCA and CNA agar were 150-1380, 456, 382-550 and 50-990, 237, 182-309, respectively. Bacterial counts on PCA significantly correlated with number of the pedestrians (r=0.89), relative humidity (r=0.70) and airborne dust (PM5.0) (r=0.73). Results of a multiple regression indicated independent positive association between the number of pedestrians and bacterial counts on PCA (p<0.01) after excluding the influence of relative humidity and airborne dust. Similar results were obtained with the statistical analysis for the counts of bacteria on CNA agar. Gram-positive cocci were dominant on PCA and CNA agar. Staphylococcus epidermidis and Micrococcus spp. were dominant among the 11 genera and 19 species identified in the present study. Considering the pattern of identified species and the significant independent association between number of pedestrians and bacterial counts, airborne bacteria in a crowded underground concourse were mostly originated from the pedestrians who were walking in the underground concourse. This study gave an evidential example of bacterial conditions in the air of an underground crowded public space in Tokyo.
The influence of dialyzer geometry on blood coagulation and biocompatibility.
Lins, L E; Boberg, U; Jacobson, S H; Kjellstrand, C; Ljungberg, B; Skröder, R
1993-11-01
The influence of dialyzer geometry on blood coagulation, heparin requirement and complement activation was studied in fourteen chronic hemodialysis patients. Each patient was dialyzed with two different cuprophan dialyzers, hollow fiber GF 120M and parallel plate Lundia IC5N. Both dialyzers had a wall thickness of 11 microns, surface area of 1.2 m2 and both were sterilized with ethylene oxide. Heparin doses were individually titrated. The mean heparin dose was 6089 +/- 988 U. Platelet count decreased from 218 x 10(9)/l to 193 x 10(9)/l and from 235 x 10(9)/l to 197 x 10(9)/l respectively (hollow fiber/plate dialyzer, ns). The number of leucocytes decreased at 15 min after start of dialysis by 56% and 61% (hollow fiber/plate dialyzer, ns). The heparin requirement, measured as prolongation of whole blood activated coagulation time after identical doses of heparin, were the same in hollow fiber and plate dialysis sessions. The arterial fibrinopeptide A concentrations increased during dialysis from 5.4 to 7.1 nmol/l and 8.5 to 9.6 nmol/l respectively (hollow fiber/plate dialyzer, ns). The residual blood volume in the hollow fiber dialyzers was 1.3 +/- 1.1 ml and in the plate dialyzers 1.5 +/- 0.9 ml (ns). C3a activation, indicated by a marked arterio-venous difference, was observed at 15 min after start of dialysis with hollow fiber as well as plate dialyzers. The arterio-venous difference was less pronounced at the end of dialysis. There were no differences in C3a activation between hollow fiber and plate dialyzers at any timepoint. It is concluded that dialyzer geometry does not significantly influence platelet count, blood coagulation, heparin requirement or complement activation.
Patrick, T E; Goodwin, T L; Collins, J A; Wyche, R C; Love, B E
1972-04-01
A comparison of two types of scalders was conducted to determine their effectiveness in reducing bacterial contamination of poultry carcasses. A conventional hot-water scalder and a prototype model of a steam scalder were tested under commercial conditions. Total plate counts from steam-scalded birds were significantly lower than the counts of water-scalded birds immediately after scalding and again after picking. No differences in the two methods could be found after chilling. Coliform counts from steam-scalded birds were significantly lower than the counts from water-scalded birds immediately after scalding. No significant differences in coliform counts were detected when the two scald methods were compared after defeathering and chilling.
Population Screening Using Sewage Reveals Pan-Resistant Bacteria in Hospital and Community Samples.
Meir-Gruber, Lital; Manor, Yossi; Gefen-Halevi, Shiraz; Hindiyeh, Musa Y; Mileguir, Fernando; Azar, Roberto; Smollan, Gill; Belausov, Natasha; Rahav, Galia; Shamiss, Ari; Mendelson, Ella; Keller, Nathan
2016-01-01
The presence of pan-resistant bacteria worldwide possesses a threat to global health. It is difficult to evaluate the extent of carriage of resistant bacteria in the population. Sewage sampling is a possible way to monitor populations. We evaluated the presence of pan-resistant bacteria in Israeli sewage collected from all over Israel, by modifying the pour plate method for heterotrophic plate count technique using commercial selective agar plates. This method enables convenient and fast sewage sampling and detection. We found that sewage in Israel contains multiple pan-resistant bacteria including carbapenemase resistant Enterobacteriacae carrying blaKPC and blaNDM-1, MRSA and VRE. blaKPC carrying Klebsiella pneumonia and Enterobacter cloacae were the most common Enterobacteriacae drug resistant bacteria found in the sewage locations we sampled. Klebsiella pneumonia, Enterobacter spp., Escherichia coli and Citrobacter spp. were the 4 main CRE isolated from Israeli sewage and also from clinical samples in our clinical microbiology laboratory. Hospitals and Community sewage had similar percentage of positive samplings for blaKPC and blaNDM-1. VRE was found to be more abundant in sewage in Israel than MRSA but there were more locations positive for MRSA and VRE bacteria in Hospital sewage than in the Community. Therefore, our upgrade of the pour plate method for heterotrophic plate count technique using commercial selective agar plates can be a useful tool for routine screening and monitoring of the population for pan-resistant bacteria using sewage.
Population Screening Using Sewage Reveals Pan-Resistant Bacteria in Hospital and Community Samples
Mileguir, Fernando; Azar, Roberto; Smollan, Gill; Belausov, Natasha; Rahav, Galia; Shamiss, Ari; Mendelson, Ella; Keller, Nathan
2016-01-01
The presence of pan-resistant bacteria worldwide possesses a threat to global health. It is difficult to evaluate the extent of carriage of resistant bacteria in the population. Sewage sampling is a possible way to monitor populations. We evaluated the presence of pan-resistant bacteria in Israeli sewage collected from all over Israel, by modifying the pour plate method for heterotrophic plate count technique using commercial selective agar plates. This method enables convenient and fast sewage sampling and detection. We found that sewage in Israel contains multiple pan-resistant bacteria including carbapenemase resistant Enterobacteriacae carrying blaKPC and blaNDM-1, MRSA and VRE. blaKPC carrying Klebsiella pneumonia and Enterobacter cloacae were the most common Enterobacteriacae drug resistant bacteria found in the sewage locations we sampled. Klebsiella pneumonia, Enterobacter spp., Escherichia coli and Citrobacter spp. were the 4 main CRE isolated from Israeli sewage and also from clinical samples in our clinical microbiology laboratory. Hospitals and Community sewage had similar percentage of positive samplings for blaKPC and blaNDM-1. VRE was found to be more abundant in sewage in Israel than MRSA but there were more locations positive for MRSA and VRE bacteria in Hospital sewage than in the Community. Therefore, our upgrade of the pour plate method for heterotrophic plate count technique using commercial selective agar plates can be a useful tool for routine screening and monitoring of the population for pan-resistant bacteria using sewage. PMID:27780222
Embedded and conventional ultrasonic sensors for monitoring acoustic emission during thermal fatigue
NASA Astrophysics Data System (ADS)
Trujillo, Blaine; Zagrai, Andrei
2016-04-01
Acoustic emission is widely used for monitoring pressure vessels, pipes, critical infrastructure, as well as land, sea and air vehicles. It is one of dominant approaches to explore material degradation under fatigue and events leading to material fracture. Addressing a recent interest in structural health monitoring of space vehicles, a need has emerged to evaluate material deterioration due to thermal fatigue during spacecraft atmospheric reentry. Thermal fatigue experiments were conducted, in which aluminum plates were subjected to localized heating and acoustic emission was monitoring by embedded and conventional acoustic emission sensors positioned at various distances from a heat source. At the same time, surface temperature of aluminum plates was monitored using an IR camera. Acoustic emission counts collected by embedded sensors were compared to counts measured with conventional acoustic emission sensors. Both types of sensors show noticeable increase of acoustic emission activity as localized heating source was applied to aluminum plates. Experimental data demonstrate correlation between temperature increase on the surface of the plates and increase in measured acoustic emission activity. It is concluded that under particular conditions, embedded piezoelectric wafer active sensors can be used for acoustic emission monitoring of thermally-induced structural degradation.
Virological and bacteriological quality of drinking water in Ethiopia
NASA Astrophysics Data System (ADS)
Bedada, Tesfaye Legesse; Mezemir, Walelign Dessie; Dera, Firehiwot Abera; Sima, Waktole Gobena; Gebre, Samson Girma; Edicho, Redwan Muzeyin; Biegna, Almaz Gonfa; Teklu, Dejenie Shiferaw; Tullu, Kassu Desta
2018-05-01
Since unsafe water is responsible for many illness, deaths, and economic failure, water quality monitoring is essential. A cross-sectional study was conducted on 218 drinking waters samples collected between February and June 2016 to assess water quality using phages by the help of CB390 E. coli host, plaque assay; multiple tube fermentation for coliforms and pour plate for heterotrophic bacteria at Ethiopian Public Health Institute. Heterotrophic plate count greater than 100 cfu/ml was noted in 41 samples and detections of total and thermotolerant coliforms and E. coli in 38, 24, and 10 samples, respectively, and no phages detection in chlorinated waters. While heterotrophic plate count greater than 100 cfu/ml was observed in 100 samples and detections of total and thermotolerant coliforms, E. coli, and phages in 75, 60, 42, and 5 samples, respectively, for untreated waters. The majority of the waters contained indicators above standard limits. This indicates that the sources are contaminated and they are potential threats for health. Hence, regular water monitoring should be a priority agenda.
NASA Technical Reports Server (NTRS)
Lisle, J. T.; Pyle, B. H.; McFeters, G. A.
1999-01-01
A suite of fluorescent intracellular stains and probes was used, in conjunction with viable plate counts, to assess the effect of chlorine disinfection on membrane potential (rhodamine 123; Rh123 and bis-(1,3-dibutylbarbituric acid) trimethine oxonol; DiBAC4(3)), membrane integrity (LIVE/DEAD BacLight kit), respiratory activity (5-cyano-2,3-ditolyl tetrazolium chloride; CTC) and substrate responsiveness (direct viable counts; DVC) in the commensal pathogen Escherichia coli O157:H7. After a 5 min exposure to the disinfectant, physiological indices were affected in the following order: viable plate counts > substrate responsiveness > membrane potential > respiratory activity > membrane integrity. In situ assessment of physiological activity by examining multiple targets, as demonstrated in this study, permits a more comprehensive determination of the site and extent of injury in bacterial cells following sublethal disinfection with chlorine. This approach to assessing altered bacterial physiology has application in various fields where detection of stressed bacteria is of interest.
NASA Technical Reports Server (NTRS)
Broadaway, Susan C.; Barton, Stephanie A.; Pyle, Barry H.
2003-01-01
The nucleic acid stain SYBR Green I was evaluated for use with solid-phase laser cytometry to obtain total bacterial cell counts from several water sources with small bacterial numbers. Results were obtained within 30 min and exceeded or equaled counts on R2A agar plates incubated for 14 days at room temperature.
Bekaert, Karen; Devriese, Lisa; Maes, Sara; Robbens, Johan
2015-04-01
The aim of this study was to investigate the microbial quality of whole Norway lobster (Nephrops norvegicus) and Norway lobster tails to optimize handling conditions. This was done by assessing the total viable count (TVC) and characterizing the dominant microbiota. The cultivable microorganisms were quantified via classical microbiological plating methods. To characterize as many bacterial species present as possible, we performed advanced molecular identification techniques (PCR-DGGE). The initial TVC of fresh Norway lobster meat was high (3.0 log cfu/g) as compared to fish. No significant difference between whole Norway lobster and Norway lobster tails could be found during the storage period. From day 6 of storage, a significant difference between Plate Count Agar (PCA) and Marine Agar (MA) was observed. The microbiota of Norway lobster was dominated by members of the Gram-negative genera such as Psychrobacter spp., Pseudoalteromonas spp., Pseudomonas spp., Luteimonas spp., and Aliivibrio spp. From these bacteria, mainly Psychrobacter spp. and Pseudomonas spp. remained present until the end of the storage period. These are known spoilage organisms in fishery products. Other known spoilage organisms of crustaceans such as Photobacterium spp. could not be identified. Copyright © 2014 Elsevier Ltd. All rights reserved.
Eddy, Russell S; Joyce, Anthony P; Roberts, Steven; Buxton, Thomas B; Liewehr, Frederick
2005-09-01
This study investigated the ability of chlorine dioxide to eliminate Enterococcus faecalis from dentinal tubules of bovine incisors. Thirty-seven extracted bovine incisor roots were sectioned into seventy-four 5 mm disks. Standardized lumens were filled with either sterile Brain Heart Infusion Broth (contamination controls, n = 10) or BHI containing E. faecalis (1.0 x 10 cfu/ml). Disks were incubated in 5% CO2 at 37 degrees C for 72 h. To simulate endodontic instrumentation the lumens were again enlarged. Sixty disks were randomly divided into four experimental groups and filled with one of the following irrigants: 10% Clidox-S (chlorine dioxide), 13.8% BioClenz (chlorine dioxide), 5.25% Clorox, or saline. The disks were incubated for 30 min and were then frozen, pulverized, serially diluted in phosphate buffered saline, and plated on BHI plates in triplicate. Total colony forming units were counted macroscopically. Statistical analysis of the data was performed with a Kruskal-Wallis one-way ANOVA on ranks (p < 0.05, n = 60). Bacterial counts, expressed in log10 cfu/disk were as follows (">" denotes significant differences): Saline > Clidox-S = BioClenz > Clorox. All negative controls were sterile. Chlorine dioxide and NaOCL were both effective in eliminating E. faecalis from the dentinal disks within 30 min.
Optimization of Uranium Molecular Deposition for Alpha-Counting Sources
DOE Office of Scientific and Technical Information (OSTI.GOV)
Monzo, Ellen; Parsons-Moss, Tashi; Genetti, Victoria
2016-12-12
Method development for molecular deposition of uranium onto aluminum 1100 plates was conducted with custom plating cells at Lawrence Livermore National Laboratory. The method development focused primarily on variation of electrode type, which was expected to directly influence plated sample homogeneity. Solid disc platinum and mesh platinum anodes were compared and data revealed that solid disc platinum anodes produced more homogenous uranium oxide films. However, the activity distribution also depended on the orientation of the platinum electrode relative to the aluminum cathode, starting current, and material composition of the plating cell. Experiments demonstrated these variables were difficult to control undermore » the conditions available. Variation of plating parameters among a series of ten deposited plates yielded variations up to 30% in deposition efficiency. Teflon particles were observed on samples plated in Teflon cells, which poses a problem for alpha activity measurements of the plates. Preliminary electropolishing and chemical polishing studies were also conducted on the aluminum 1100 cathode plates.« less
Patrick, Thomas E.; Goodwin, T. L.; Collins, J. A.; Wyche, R. C.; Love, B. E.
1972-01-01
A comparison of two types of scalders was conducted to determine their effectiveness in reducing bacterial contamination of poultry carcasses. A conventional hot-water scalder and a prototype model of a steam scalder were tested under commercial conditions. Total plate counts from steam-scalded birds were significantly lower than the counts of water-scalded birds immediately after scalding and again after picking. No differences in the two methods could be found after chilling. Coliform counts from steam-scalded birds were significantly lower than the counts from water-scalded birds immediately after scalding. No significant differences in coliform counts were detected when the two scald methods were compared after defeathering and chilling. PMID:4553146
Coliphages as indicators of enteroviruses.
Stetler, R E
1984-01-01
Coliphages were monitored in conjunction with indicator bacteria and enteroviruses in a drinking-water plant modified to reduce trihalomethane production. Coliphages could be detected in the source water by direct inoculation, and sufficient coliphages were detected in enterovirus concentrates to permit following the coliphage levels through different water treatment processes. The recovery efficiency by different filter types ranged from 1 to 53%. Statistical analysis of the data indicated that enterovirus isolates were better correlated with coliphages than with total coliforms, fecal coliforms, fecal streptococci, or standard plate count organisms. Coliphages were not detected in finished water. PMID:6093694
Is there an association between airborne and surface microbes in the critical care environment?
Smith, J; Adams, C E; King, M F; Noakes, C J; Robertson, C; Dancer, S J
2018-04-09
There are few data and no accepted standards for air quality in the intensive care unit (ICU). Any relationship between airborne pathogens and hospital-acquired infection (HAI) risk in the ICU remains unknown. First, to correlate environmental contamination of air and surfaces in the ICU; second, to examine any association between environmental contamination and ICU-acquired staphylococcal infection. Patients, air, and surfaces were screened on 10 sampling days in a mechanically ventilated 10-bed ICU for a 10-month period. Near-patient hand-touch sites (N = 500) and air (N = 80) were screened for total colony count and Staphylococcus aureus. Air counts were compared with surface counts according to proposed standards for air and surface bioburden. Patients were monitored for ICU-acquired staphylococcal infection throughout. Overall, 235 of 500 (47%) surfaces failed the standard for aerobic counts (≤2.5 cfu/cm 2 ). Half of passive air samples (20/40: 50%) failed the 'index of microbial air' contamination (2 cfu/9 cm plate/h), and 15/40 (37.5%) active air samples failed the clean air standard (<10 cfu/m 3 ). Settle plate data were closer to the pass/fail proportion from surfaces and provided the best agreement between air parameters and surfaces when evaluating surface benchmark values of 0-20 cfu/cm 2 . The surface standard most likely to reflect hygiene pass/fail results compared with air was 5 cfu/cm 2 . Rates of ICU-acquired staphylococcal infection were associated with surface counts per bed during 72h encompassing sampling days (P = 0.012). Passive air sampling provides quantitative data analogous to that obtained from surfaces. Settle plates could serve as a proxy for routine environmental screening to determine the infection risk in ICU. Copyright © 2018 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.
Eglezos, Sofroni; Huang, Bixing; Stuttard, Ed
2008-02-01
There is little information about bacteriological quality of preroasted kernels available in the public domain. An investigation of the bacteriological quality of preroasted peanut, almond, cashew, hazelnut, and Brazil nut kernels received into three Australian nut-processing facilities was performed over a period of 3 years. A total of 836 samples were analyzed for aerobic plate count, and 921 samples for Salmonella and Escherichia coli. The 921 samples included 653 peanut, 100 cashew, 60 almond, 60 Brazil nut, and 48 hazelnut kernels. There was no E. coli detected in any sample. Salmonella subsp. II (Fremantle) was detected in one raw almond sample. The aerobic plate count percentages of positive samples with counts above the detection level of the plating method used (100 CFU/g) for peanuts, almonds, cashews, hazelnuts, and Brazil nuts were 84, 78, 74, 50, and 45%, respectively. Of the samples containing more than this detection limit, the means were 4.5, 4.4, 3.1, 2.5, and 3.8 log CFU/g respectively. Although roasted kernel quality was not within the scope of this survey, raw microbial bioload would be expected to reduce on roasting. The bacteriological quality of preroasted peanut, almond, cashew, hazelnut, and Brazil nut kernels received into nut-processing facilities in Australia does not appear to suggest a public health concern.
Shao, Yuyu; Wang, Zhaoxia; Bao, Qiuhua; Zhang, Heping
2017-11-01
Differential enumeration of subpopulations in concentrated frozen and lyophilized cultures of Lactobacillus delbrueckii ssp. bulgaricus ND02 derived from 2 propagation procedures was determined. The subpopulations consisted of 3 categories (physiological states): viable cells capable of forming colonies on agar plates (VC+), viable cells incapable of forming colonies on agar plates (VC-), widely referred to as viable but nonculturable (VBNC) cells, and nonviable or dead cells (NVC). Counts of VC+ were recorded using a conventional plate count procedure. A fluorescent vital staining procedure that discriminates between viable (VC+ and VC-) and NVC cells was used to determine the number of viable and nonviable cells. Both propagation procedures had 2 variables: in procedure (P)1, the propagation medium was rich in yeast extract (4.0%) and the pH was maintained at 5.7; in P2, the medium was devoid of yeast extract and the pH was maintained at 5.1. The results showed that post-propagation operations-concentration of cells by centrifugation and subsequent freezing or lyophilization of cell concentrate-induced different degrees of transience from VC+ to VC- states in cells derived from P1 and P2. Compared with cells derived from P2, cells from P1 were more labile to stress associated with centrifugation, freezing, and lyophilization, as revealed by differential counting. Copyright © 2017 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
Armengol, Ramon; Fraile, Lorenzo
2016-06-01
The objective of the study was to evaluate if on-farm heat treatment of colostrum and bulk tank milk can improve calf health status and morbidity and mortality rates during the first 21d of life in neonatal Holstein calves receiving appropriate colostrum ingestion. A total of 587 calves were randomly assigned to 2 groups of males and females over 18mo. The nonpasteurized group (n=287, 143 males and 144 females) was fed frozen (-20°C) colostrum (6-8L during the first 12h of life) that was previously reheated up to 40°C. They were also fed refrigerated (4°C) raw milk from the bulk tank that was also reheated up to 40°C (1.8L every 12h). The pasteurized group (n=300, 150 males and 150 females) was also fed colostrum and milk, but both were pasteurized before freezing. Blood samples were drawn from all calves to obtain serum at 2 to 5d of life. Serum total protein (g/dL) was determined using a commercially available refractometer. Colostrum and milk underwent routine bacteriological analysis to determine total plate counts (cfu/mL) and total coliform counts (cfu/mL). All the calves underwent clinical examination every 24h during the first 21d of life. Every day, calves were clinically diagnosed either as being healthy or suffering from respiratory disease, neonatal calf diarrhea, or suffering other diseases. On-farm heat treatment for colostrum and milk reduced total plate counts and total coliform counts between 1 and 2 log10. Pasteurization of colostrum and milk significantly decreased the morbidity and mortality (5.2 and 2.8%) in comparison with calves receiving nonpasteurized colostrum and milk (15.0 and 6.5%), respectively, during the first 21d of life, even in animals receiving appropriate colostrum ingestion. Copyright © 2016 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
Prevalence of Vibrio vulnificus and Vibrio parahaemolyticus in the Maryland Coastal Bays
NASA Astrophysics Data System (ADS)
De Pascuale, V. O.
2016-02-01
The bacterial family of Vibrionaceae is indigenous in the marine estuarine environments such as the Maryland Coastal Bays. Vibrio vulnificus and Vibrio parahaemolyticus are both pathogenic bacteria. Understanding the distribution of Vibrio species is crucial because of the health concerns associated with the bacteria. The aim of this study was to evaluate the overall abundance of bacteria with a focus on Vibrio species in the Maryland Coastal Bays. Seawater samples were collected from 10 different sites that differ with regard to water quality. The total bacteria count (TBC) was determined by two methods: Total plate count and Epifluorescence microscopy. The most-probable-number (MPN) methodology was used to estimate the population of Vibrio parahaemolyticus and Vibrio vulnificus. In addition to the bacteriological analysis, the environmental parameters of temperature and salinity were measured using YSI 6600 multiparameter meter. The average total bacteria count was 2.21 log CFU ml-1. Vibrio vulnificus comprised 5% of the total bacteria count while Vibrio parahaemolyticus comprised only 2% of the total bacteria count. Vibrio vulnificus ranged from 0.30 to 2.48 log MPN ml-1 at the sites tested. Lower Vibrio parahaemolyticus count was observed at the sites with a range of 0.30 to 1.97 log MPN ml-1. There was no significant correlation between the environmental parameters and the Vibrio spp. Since both Vibrio vulnificus and Vibrio parahaemolyticus peak in the summer, there is a potential for a risk of wound infections and gastrointestinal illness based on this data.
Use of hot water for beef carcass decontamination.
Castillo, A; Lucia, L M; Goodson, K J; Savell, J W; Acuff, G R
1998-01-01
Hot water treatment of beef carcass surfaces for reduction of Escherichia coli O157:H7, Salmonella typhimurium, and various indicator organisms was studied using a model carcass spray cabinet. Paired hot carcass surface regions with different external fat characteristics (inside round, outside round, brisket, flank, and clod) were removed from carcasses immediately after the slaughter and dressing process. All cuts were inoculated with bovine feces containing 10(6)/g each of rifampicin-resistant E. coli O157:H7 and S. typhimurium, or with uninoculated bovine feces. Surfaces then were exposed to a carcass water wash or a water wash followed by hot water spray (95 degrees C). Counts of rifampicin-resistant Salmonella and E. coli or aerobic plate count (APC) and coliform counts were conducted before and after each treatment. All treatments significantly reduced levels of pathogens from the initial inoculation level of 5.0 log(10) CFU/cm2. Treatments including hot water sprays provided mean reductions of initial counts for E. coli O157:H7 and S. typhimurium of 3.7 and 3.8 log, APC reductions of 2.9 log, and coliform and thermotolerant coliform count reductions of 3.3 log. The efficacy of hot water treatments was affected by the carcass surface region, but not by delaying the treatment (30 min) after contaminating the surface. Verification of efficacy of hot water interventions used as critical control points in a hazard analysis critical control point (HACCP) system may be possible using coliform counts.
Whyte, P; Collins, J D; McGill, K; Monahan, C; O'Mahony, H
2001-03-01
Airborne microbial contaminants and indicator organisms were monitored within three poultry processing plants (plants A, B, and C). In total, 15 cubic feet (c.f.) of air was sampled per location during 15 visits to each plant and quantitatively analyzed for total mesophilic and psychrophilic aerobic counts, thermophilic campylobacters, Escherichia coli, and Enterobacteriaceae. The prevalence of Salmonella spp. in air samples was also evaluated. Significant reductions in total aerobic counts were observed between defeathering and evisceration areas of the three plants (P < 0.05). Mesophilic plate counts were highest in the defeathering areas of all plants compared to equivalent psychrophilic plate counts. Enterobacteriaceae counts were highest in the defeathering areas of all three plants with counts of log10 1.63, 1.53, and 1.18 CFU/15 c.f. recovered in plants A, B, and C, respectively. E. coli enumerated from air samples in the defeathering areas exhibited a similar trend to those obtained for Enterobacteriaceae with log10 1.67, 1.58, and 1.18 CFU for plants A, B, and C, respectively. Thermophilic campylobacters were most frequently isolated from samples in the defeathering areas followed by the evisceration areas. The highest mean counts of the organism were observed in plant A at 21 CFU/15 c.f. sample with plants B and C at 9 and 8 CFU/sample, respectively. With the exception of low levels of Enterobacteriaceae recovered from samples in the on-line air chill in plant A, E. coli, Enterobacteriaceae, or Campylobacter spp. were not isolated from samples in postevisceration sites in any of the plants examined. Salmonella spp. were not recovered from any samples during the course of the investigation.
The degree of bacterial contamination while performing spine surgery.
Ahn, Dong Ki; Park, Hoon Seok; Kim, Tae Woo; Yang, Jong Hwa; Boo, Kyung Hwan; Kim, In Ja; Lee, Hye Jin
2013-03-01
Prospective experimental study. To evaluate bacterial contamination during surgery. The participants of surgery and ventilation system have been known as the most significant sources of contamination. Two pairs of air culture blood agar plate for G(+) bacteria and MacConkey agar plate for G(-) bacteria were placed at 3 different locations in a conventional operation room: in the surgical field, under the airflow of local air conditioner, and pathway to door while performing spine surgeries. One pair of culture plates was retrieved after one hour and the other pair was retrieved after 3 hours. The cultured bacteria were identified and number of colonies was counted. There was no G(-) bacteria identified. G(+) bacteria grew on all 90 air culture blood agar plates. The colony count of one hour group was 14.5±5.4 in the surgical field, 11.3±6.6 under the local air conditioner, and 13.1±8.7 at the pathway to the door. There was no difference among the 3 locations. The colony count of 3 hours group was 46.4±19.5, 30.3±12.9, and 39.7±15.2, respectively. It was more at the surgical field than under the air conditioner (p=0.03). The number of colonies of one hour group was 13.0±7.0 and 3 hours group was 38.8±17.1. There was positive correlation between the time and the number of colonies (r=0.76, p=0.000). Conventional operation room was contaminated by G(+) bacteria. The degree of contamination was most high at the surgical field. The number of bacteria increased right proportionally to the time.
The Degree of Bacterial Contamination While Performing Spine Surgery
Ahn, Dong Ki; Park, Hoon Seok; Yang, Jong Hwa; Boo, Kyung Hwan; Kim, In Ja; Lee, Hye Jin
2013-01-01
Study Design Prospective experimental study. Purpose To evaluate bacterial contamination during surgery. Overview of Literature The participants of surgery and ventilation system have been known as the most significant sources of contamination. Methods Two pairs of air culture blood agar plate for G(+) bacteria and MacConkey agar plate for G(-) bacteria were placed at 3 different locations in a conventional operation room: in the surgical field, under the airflow of local air conditioner, and pathway to door while performing spine surgeries. One pair of culture plates was retrieved after one hour and the other pair was retrieved after 3 hours. The cultured bacteria were identified and number of colonies was counted. Results There was no G(-) bacteria identified. G(+) bacteria grew on all 90 air culture blood agar plates. The colony count of one hour group was 14.5±5.4 in the surgical field, 11.3±6.6 under the local air conditioner, and 13.1±8.7 at the pathway to the door. There was no difference among the 3 locations. The colony count of 3 hours group was 46.4±19.5, 30.3±12.9, and 39.7±15.2, respectively. It was more at the surgical field than under the air conditioner (p=0.03). The number of colonies of one hour group was 13.0±7.0 and 3 hours group was 38.8±17.1. There was positive correlation between the time and the number of colonies (r=0.76, p=0.000). Conclusions Conventional operation room was contaminated by G(+) bacteria. The degree of contamination was most high at the surgical field. The number of bacteria increased right proportionally to the time. PMID:23508998
Development of a nematode offspring counting assay for rapid and simple soil toxicity assessment.
Kim, Shin Woong; Moon, Jongmin; Jeong, Seung-Woo; An, Youn-Joo
2018-05-01
Since the introduction of standardized nematode toxicity assays by the American Society for Testing and Materials (ASTM) and International Organization for Standardization (ISO), many studies have reported their use. Given that the currently used standardized nematode toxicity assays have certain limitations, in this study, we examined the use of a novel nematode offspring counting assay for evaluating soil ecotoxicity based on a previous soil-agar isolation method used to recover live adult nematodes. In this new assay, adult Caenorhabditis elegans were exposed to soil using a standardized toxicity assay procedure, and the resulting offspring in test soils attracted by a microbial food source in agar plates were counted. This method differs from previously used assays in terms of its endpoint, namely, the number of nematode offspring. The applicability of the bioassay was demonstrated using metal-spiked soils, which revealed metal concentration-dependent responses, and with 36 field soil samples characterized by different physicochemical properties and containing various metals. Principal component analysis revealed that texture fraction (clay, sand, and silt) and electrical conductivity values were the main factors influencing the nematode offspring counting assay, and these findings warrant further investigation. The nematode offspring counting assay is a rapid and simple process that can provide multi-directional toxicity assessment when used in conjunction with other standard methods. Copyright © 2018 Elsevier Ltd. All rights reserved.
Hazard analysis and critical point identification at Abiss slaughter house in Alexandria.
Gomaa, N F; El-Derea, H B; ElI-Adham, E
2003-01-01
The purpose of this study is to identify potential hazards associated with animal slaughtering and how could these affect the microbiological count of carcasses, and to describe the use of HACCP to improve the microbiological count of fresh meat. Hazards were detected by observing the different steps of animal slaughter and then filling a prepared red meat slaughterhouse score sheet. The microbiological load was determined through testing 112 swab samples taken from the surface of carcasses in addition to 21 samples from hands, knives, tap water and air. Results showed that most of the parameters of the score sheet observed for evaluating hygienic operations were classified as being of maximum risk C. The aerobic plate count enterobacteriacea, mold and yeast and staphylococci increased insignificantly after cutting to 9.7x10(2), 6.4x10, 2.6x10(2), and 3.7x10 cfu/cm2, respectively. Washing of the carcasses decreased counts insignificantly to 6.4x10(2), 2.0x10, 1.7x10(2), and 2.0x10 cfu/cm2, respectively. The microbiological count of air samples at quiet hours were lower insignificantly than those at busy hours. Subsequently a HACCP system was designed based on these microbial studies, observations of current practices within the slaughterhouse and relevant literature and following the 7 principles of HACCP.
Karulin, Alexey Y; Caspell, Richard; Dittrich, Marcus; Lehmann, Paul V
2015-03-02
Accurate assessment of positive ELISPOT responses for low frequencies of antigen-specific T-cells is controversial. In particular, it is still unknown whether ELISPOT counts within replicate wells follow a theoretical distribution function, and thus whether high power parametric statistics can be used to discriminate between positive and negative wells. We studied experimental distributions of spot counts for up to 120 replicate wells of IFN-γ production by CD8+ T-cell responding to EBV LMP2A (426 - 434) peptide in human PBMC. The cells were tested in serial dilutions covering a wide range of average spot counts per condition, from just a few to hundreds of spots per well. Statistical analysis of the data using diagnostic Q-Q plots and the Shapiro-Wilk normality test showed that in the entire dynamic range of ELISPOT spot counts within replicate wells followed a normal distribution. This result implies that the Student t-Test and ANOVA are suited to identify positive responses. We also show experimentally that borderline responses can be reliably detected by involving more replicate wells, plating higher numbers of PBMC, addition of IL-7, or a combination of these. Furthermore, we have experimentally verified that the number of replicates needed for detection of weak responses can be calculated using parametric statistics.
Clais, S; Boulet, G; Van Kerckhoven, M; Lanckacker, E; Delputte, P; Maes, L; Cos, P
2015-01-01
The viable plate count (VPC) is considered as the reference method for bacterial enumeration in periodontal microbiology but shows some important limitations for anaerobic bacteria. As anaerobes such as Porphyromonas gingivalis are difficult to culture, VPC becomes time-consuming and less sensitive. Hence, efficient normalization of experimental data to bacterial cell count requires alternative rapid and reliable quantification methods. This study compared the performance of VPC with that of turbidity measurement and real-time PCR (qPCR) in an experimental context using highly concentrated bacterial suspensions. Our TaqMan-based qPCR assay for P. gingivalis 16S rRNA proved to be sensitive and specific. Turbidity measurements offer a fast method to assess P. gingivalis growth, but suffer from high variability and a limited dynamic range. VPC was very time-consuming and less repeatable than qPCR. Our study concludes that qPCR provides the most rapid and precise approach for P. gingivalis quantification. Although our data were gathered in a specific research context, we believe that our conclusions on the inferior performance of VPC and turbidity measurements in comparison to qPCR can be extended to other research and clinical settings and even to other difficult-to-culture micro-organisms. Various clinical and research settings require fast and reliable quantification of bacterial suspensions. The viable plate count method (VPC) is generally seen as 'the gold standard' for bacterial enumeration. However, VPC-based quantification of anaerobes such as Porphyromonas gingivalis is time-consuming due to their stringent growth requirements and shows poor repeatability. Comparison of VPC, turbidity measurement and TaqMan-based qPCR demonstrated that qPCR possesses important advantages regarding speed, accuracy and repeatability. © 2014 The Society for Applied Microbiology.
NASA Astrophysics Data System (ADS)
Salançon, Evelyne; Degiovanni, Alain; Lapena, Laurent; Morin, Roger
2018-04-01
An event-counting method using a two-microchannel plate stack in a low-energy electron point projection microscope is implemented. 15 μm detector spatial resolution, i.e., the distance between first-neighbor microchannels, is demonstrated. This leads to a 7 times better microscope resolution. Compared to previous work with neutrons [Tremsin et al., Nucl. Instrum. Methods Phys. Res., Sect. A 592, 374 (2008)], the large number of detection events achieved with electrons shows that the local response of the detector is mainly governed by the angle between the hexagonal structures of the two microchannel plates. Using this method in point projection microscopy offers the prospect of working with a greater source-object distance (350 nm instead of 50 nm), advancing toward atomic resolution.
The effect of laminar air flow and door openings on operating room contamination.
Smith, Eric B; Raphael, Ibrahim J; Maltenfort, Mitchell G; Honsawek, Sittisak; Dolan, Kyle; Younkins, Elizabeth A
2013-10-01
We evaluate the association of laminar airflow (LAF) and OR traffic with intraoperative contamination rates. Two sterile basins were placed in each room during 81 cases, one inside and one outside the LAF. One Replicate Organism Detection and Counting (RODAC) plate from each basin was sent for culture at successive 30-minute intervals from incision time until wound closure. At successive 30-minute intervals more plates were contaminated outside than inside the LAF. A negative binomial model showed that the bacteria colony forming units (CFU) depended on whether there were any door openings (P=0.02) and the presence of LAF (P=0.003). LAF decreases CFU by 36.6%. LAF independently reduces the risk of contamination and microbial counts for surgeries lasting 90 minutes or less. © 2013.
Reborn quadrant anode image sensor
NASA Astrophysics Data System (ADS)
Prokazov, Yury; Turbin, Evgeny; Vitali, Marco; Herzog, Andreas; Michaelis, Bernd; Zuschratter, Werner; Kemnitz, Klaus
2009-06-01
We describe a position sensitive photon counting microchannel plate based detector with an improved quadrant anode (QA) readout system. The technique relies on a combination of the four planar elements pattern and an additional fifth electrode. The charge cloud induced by single particle detection is split between the electrodes. The measured charge values uniquely define the position of the initial event. QA has been first published in 1976 by Lampton and Malina. This anode configuration was undeservedly forgotten and its potential has been hardly underestimated. The presented approach extends the operating spatial range to the whole sensitive area of the microchannel plate surface and demonstrates good linearity over the field of view. Therefore, the novel image sensor results in spatial resolution better then 50 μm and count rates up to one million events per second.
Single electron counting using a dual MCP assembly
NASA Astrophysics Data System (ADS)
Yang, Yuzhen; Liu, Shulin; Zhao, Tianchi; Yan, Baojun; Wang, Peiliang; Yu, Yang; Lei, Xiangcui; Yang, Luping; Wen, Kaile; Qi, Ming; Heng, Yuekun
2016-09-01
The gain, pulse height resolution and peak-to-valley ratio of single electrons detected by using a Chevron configured Microchannel Plate (MCP) assembly are studied. The two MCPs are separated by a 280 μm gap and are biased by four electrodes. The purpose of the study is to determine the optimum bias voltage arrangements for single electron counting. By comparing the results of various bias voltage combinations, we conclude that good performance for the electron counting can be achieved by operating the MCP assembly in saturation mode. In addition, by applying a small reverse bias voltage across the gap while adjusting the bias voltages of the MCPs, optimum performance of electron counting can be obtained.
Physiological responses of bacteria in biofilms to disinfection.
Yu, F P; McFeters, G A
1994-01-01
In situ enumeration methods using fluorescent probes and a radioisotope labelling technique were applied to evaluate physiological changes of Klebsiella pneumoniae within biofilms after disinfection treatment. Chlorine (0.25 mg of free chlorine per liter [pH 7.2]) and monochloramine (1 mg/liter [pH 9.0]) were employed as disinfectants in the study. Two fluorgenic compounds, 5-cyano-2,3-ditolyl tetrazolium chloride and rhodamine 123, and tritiated uridine incorporation were chosen for assessment of physiological activities. Results obtained by these methods were compared with those from the plate count and direct viable count methods. 5-Cyano-2,3-ditolyl tetrazolium chloride is an indicator of bacterial respiratory activity, rhodamine 123 is incorporated into bacteria in response to transmembrane potential, and the incorporation of uridine represents the global RNA turnover rate. The results acquired by these methods following disinfection exposure showed a range of responses and suggested different physiological reactions in biofilms exposed to chlorine and monochloramine. The direct viable count response and respiratory activity were affected more by disinfection than were the transmembrane potential and RNA turnover rate on the basis of comparable efficiency as evaluated by plate count enumeration. Information revealed by these approaches can provide different physiological insights that may be used in evaluating the efficacy of biofilm disinfection. PMID:8074525
Experimental Study for Automatic Colony Counting System Based Onimage Processing
NASA Astrophysics Data System (ADS)
Fang, Junlong; Li, Wenzhe; Wang, Guoxin
Colony counting in many colony experiments is detected by manual method at present, therefore it is difficult for man to execute the method quickly and accurately .A new automatic colony counting system was developed. Making use of image-processing technology, a study was made on the feasibility of distinguishing objectively white bacterial colonies from clear plates according to the RGB color theory. An optimal chromatic value was obtained based upon a lot of experiments on the distribution of the chromatic value. It has been proved that the method greatly improves the accuracy and efficiency of the colony counting and the counting result is not affected by using inoculation, shape or size of the colony. It is revealed that automatic detection of colony quantity using image-processing technology could be an effective way.
Seo, K H; Mitchell, B W; Holt, P S; Gast, R K
2001-01-01
The bactericidal effect of high levels of negative ions was studied using a custom-built electrostatic space charge device. To investigate whether the ion-enriched air exerted a bactericidal effect, an aerosol containing Salmonella Enteritidis (SE) was pumped into a sealed plastic chamber. Plates of XLT4 agar were attached to the walls, top, and bottom of the chamber and exposed to the aerosol for 3 h with and without the ionizer treatment. The plates were then removed from the chamber, incubated at 37 degrees C for 24 h, and colonies were counted. An average of greater than 10(3) CFU/plate were observed on plates exposed to the aerosol without the ionizer treatment (control) compared with an average of less than 53 CFU/plate on the ionizer-treated plates. In another series of experiments, the SE aerosol was pumped for 3 h into an empty chamber containing only the ionizer and allowed to collect on the internal surfaces. The inside surfaces of the chamber were then rinsed with 100 ml phosphate-buffered saline that was then plated onto XLT4 plates. While the rinse from the control chamber contained colony counts greater than 400 CFU/ml of wash, no colonies were found in the rinse from the ionizer-treatment chamber. These results indicate that high levels of negative air ions can have a significant impact on the airborne microbial load, and that most of this effect is through direct killing of the organisms. This technology, which also causes significant reduction in airborne dust, has already been successfully applied for poultry hatching cabinets and caged layer rooms. Other potential applications include any enclosed space such as food processing areas, medical institutions, the workplace, and the home, where reduction of airborne and surface pathogens is desired.
PCR-DGGE analysis of bacterial community dynamics in kava beverages during refrigeration.
Dong, J; Kandukuru, P; Huang, A S; Li, Y
2011-07-01
Kava beverages are highly perishable even under refrigerated conditions. This study aimed to investigate the bacterial community dynamics in kava beverages during refrigeration. Four freshly made kava beverages were obtained from kava bars and stored at 4°C. On days 0, 3 and 6, the aerobic plate count (APC), lactic acid bacteria (LAB) count and yeast and mould count (YMC) of the samples were determined. Meanwhile, bacterial DNA was extracted from each sample and subjected to the polymerase chain reaction-denaturing gradient gel electrophoresis (PCR-DGGE). Moreover, species-specific PCR assays were employed to identify predominant Pseudomonas spp. involved in kava spoilage. Over the storage period, the APC, LAB count and YMC of the four kava beverages all increased, whereas their pH values decreased. The DGGE profile revealed diverse bacterial populations in the samples. LAB, such as Weissella soli, Lactobacillus spp. and Lactococcus lactis, were found in the kava beverages. Species-specific PCR assays detected Pseudomonas putida and Pseudomonas fluorescens in the samples; Ps. fluorescens became dominant during refrigeration. LAB and Pseudomonas may play a significant role in the spoilage of kava beverages. This study provides important information that may be used to extend the shelf life of kava beverages. © 2011 The Authors. Letters in Applied Microbiology © 2011 The Society for Applied Microbiology.
Vandeweyer, D; Crauwels, S; Lievens, B; Van Campenhout, L
2017-02-02
The rising interest in insects for human consumption and the changing regulations in Europe require a profound insight into the food safety of insects reared and sold in Western society. The microbial quality of edible insects has only been studied occasionally. This study aimed at generating an overview of intrinsic parameters (pH, water activity and moisture content) and microbial quality of fresh mealworm larvae and crickets for several rearing companies and for several batches per rearer. In total, 21 batches obtained from 7 rearing companies were subjected to analysis of intrinsic parameters, a range of plate counts and presence-absence tests for Salmonella spp. and Listeria monocytogenes. The microbial counts of the fresh insects were generally high. Different rearing batches from a single rearing company showed differences in microbial counts which could not be explained by variations in intrinsic properties. The largest variations were found in numbers of bacterial endospores, psychrotrophs and fungi. Salmonella spp. and L. monocytogenes were not detected in any of the samples. Altogether, our study shows that large variations were found between batches from individual rearers. As a consequence, no overall differences between rearers could be observed. Copyright © 2016 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Lehmann, I.; Scholz, R.-D.
1997-04-01
We present new tidal radii for seven Galactic globular clusters using the method of automated star counts on Schmidt plates of the Tautenburg, Palomar and UK telescopes. The plates were fully scanned with the APM system in Cambridge (UK). Special account was given to a reliable background subtraction and the correction of crowding effects in the central cluster region. For the latter we used a new kind of crowding correction based on a statistical approach to the distribution of stellar images and the luminosity function of the cluster stars in the uncrowded area. The star counts were correlated with surface brightness profiles of different authors to obtain complete projected density profiles of the globular clusters. Fitting an empirical density law (King 1962) we derived the following structural parameters: tidal radius r_t_, core radius r_c_ and concentration parameter c. In the cases of NGC 5466, M 5, M 12, M 13 and M 15 we found an indication for a tidal tail around these objects (cf. Grillmair et al. 1995).
Marcinkowska-Lesiak, Monika; Poławska, Ewa; Wierzbicka, Agnieszka
2017-03-01
The aim of this study was to determine the influence of different packaging materials on meat quality during cold storage. Therefore pork loins (m. longissimus thoracis et lumborum) obtained from crossbred pigs (Polish Landrance x Duroc, n = 6) were stored at 2 ℃ in modified atmosphere packs (80% O 2 , 20% CO 2 ) in four types of trays, which differ in gas permeability. Physicochemical (headspace gas composition, pH, colour, drip loss, cooking loss, shear force, the basic composition and fatty acid profile) and microbiological ( Salmonella spp., Escherichia coli, Enterobacteriaceae, total aerobic plates count, total psychrotrophic bacteria count, the number of lactic acid bacteria, Pseudomonas spp., the general amount of yeast and mold) parameters were monitored for up to 12 days. At the end of the storage period no differences in most physicochemical properties of pork loin due to type of packaging were found, however trays with high gas permeability had the greatest impact on total aerobic plates count and Pseudomonas spp. growth.
High-Dose Neutron Detector Development Using 10B Coated Cells
DOE Office of Scientific and Technical Information (OSTI.GOV)
Menlove, Howard Olsen; Henzlova, Daniela
2016-11-08
During FY16 the boron-lined parallel-plate technology was optimized to fully benefit from its fast timing characteristics in order to enhance its high count rate capability. To facilitate high count rate capability, a novel fast amplifier with timing and operating properties matched to the detector characteristics was developed and implemented in the 8” boron plate detector that was purchased from PDT. Each of the 6 sealed-cells was connected to a fast amplifier with corresponding List mode readout from each amplifier. The FY16 work focused on improvements in the boron-10 coating materials and procedures at PDT to significantly improve the neutron detectionmore » efficiency. An improvement in the efficiency of a factor of 1.5 was achieved without increasing the metal backing area for the boron coating. This improvement has allowed us to operate the detector in gamma-ray backgrounds that are four orders of magnitude higher than was previously possible while maintaining a relatively high counting efficiency for neutrons. This improvement in the gamma-ray rejection is a key factor in the development of the high dose neutron detector.« less
Magwedere, K; Shilangale, R; Mbulu, R S; Hemberger, Y; Hoffman, L C; Dziva, F
2013-01-01
To assess the microbiological quality and safety of export game meat; i) a total of 80 pooled meat samples for aerobic plate count (APC) and Enterobacteriaceae ii) water used in harvesting and processing for microbiological quality and iii) meat and rectal contents for Salmonella spp. and Shiga toxin Escherichia coli (STEC) were evaluated in 2009 and 2010. No differences (p>0.05) in the APCs were observed between the years, but the mean Enterobacteriaceae count for 2009 was 1.33 ± 0.69 log(10)cfu/cm(2) compared to 2.93 ± 1.50 log(10)cfu/cm(2) for 2010. Insignificant Heterotrophic Plate Count (HPC) levels were detected in 9/23 field water samples, while fecal bacterial (coliforms, Clostridium perfringens and enterococci) were absent in all samples. No Salmonella spp. was isolated and all E. coli isolates from meat were negative for STEC virulence genes (stx1, stx2, eae and hlyA), suggesting a negligible role by springbok in the epidemiology of STEC and Salmonella. Copyright © 2012 Elsevier Ltd. All rights reserved.
High precision refractometry based on Fresnel diffraction from phase plates.
Tavassoly, M Taghi; Naraghi, Roxana Rezvani; Nahal, Arashmid; Hassani, Khosrow
2012-05-01
When a transparent plane-parallel plate is illuminated at a boundary region by a monochromatic parallel beam of light, Fresnel diffraction occurs because of the abrupt change in phase imposed by the finite change in refractive index at the plate boundary. The visibility of the diffraction fringes varies periodically with changes in incident angle. The visibility period depends on the plate thickness and the refractive indices of the plate and the surrounding medium. Plotting the phase change versus incident angle or counting the visibility repetition in an incident-angle interval provides, for a given plate thickness, the refractive index of the plate very accurately. It is shown here that the refractive index of a plate can be determined without knowing the plate thickness. Therefore, the technique can be utilized for measuring plate thickness with high precision. In addition, by installing a plate with known refractive index in a rectangular cell filled with a liquid and following the described procedures, the refractive index of the liquid is obtained. The technique is applied to measure the refractive indices of a glass slide, distilled water, and ethanol. The potential and merits of the technique are also discussed.
NASA Technical Reports Server (NTRS)
Lauer, J. L.; King, V. W.
1979-01-01
A far-infrared interferometer was converted into an emission microspectrophotometer for surface analysis. To cover the mid-infrared as well as the far-infrared the Mylar beamsplitter was made replaceable by a germanium-coated salt plate, and the Moire fringe counting system used to locate the moveable Michelson mirror was improved to read 0.5 micron of mirror displacement. Digital electronics and a dedicated minicomputer were installed for data collection and processing. The most critical element for the recording of weak emission spectra from small areas was, however, a reflecting microscope objective and phase-locked signal detection with simultaneous referencing to a blackbody source. An application of the technique to lubrication problems is shown.
Extinction map of Chamaeleon I molecular cloud with DENIS star counts.
NASA Astrophysics Data System (ADS)
Cambresy, L.; Epchtein, N.; Copet, E.; de Batz, B.; Kimeswenger, S.; Le Bertre, T.; Rouan, D.; Tiphene, D.
1997-08-01
Massive, large scale star counts in the J (1.25μm) band provided by the Deep Near Infrared Survey of the Southern Sky (DENIS) are used for the first time to draw out an extinction map of the Chamaeleon I dark cloud. We derived a 2' resolution map of the cloud from J star counts within an area of 1.5°x3° around the centre of the cloud using an adaptive grid method and applying a wavelet decomposition. Possible contaminating young stellar objects within the cloud are removed, although they are shown to have a negligible effect on the counts. A comparison of our extinction map with the cold contribution of the IRAS 100μm emission shows an almost perfect matching. It is shown that J star counts supersede optical counts on Schmidt plate where A_V_>4.
NASA Astrophysics Data System (ADS)
Fu, Yanshu; Qiu, Yaohui; Li, Yulong
2018-03-01
The mechanical anisotropy of an explosive welding composite plate made of 304 stainless steel/245 steel was studied through shear experiments performed on explosively welded wavy interfaces along several orientation angles. The results indicated that the strength and the fracture energy of samples significantly varied with the orientation angles. The fracture surfaces of all samples were observed using a scanning electron microscope and through three-dimensional structure microscopy. The periodic features of all the fracture surfaces were clearly shown in different fracture modes. The fractal dimension of the fracture surfaces was calculated based on the fractal geometry by the box-counting method in MATLAB. The cohesive element model was used to analyze the fracture energy according to the physical dependence of the fractal dimension on thermodynamic entropy and interface separation energy. The fracture energy was an exponential function of the fractal dimension value, which was in good agreement with the experimental results. All results were validated for effective use in the application of anisotropy analysis to the welded interface and structural optimization of explosively welded composite plates.
NASA Astrophysics Data System (ADS)
Fu, Yanshu; Qiu, Yaohui; Li, Yulong
2018-05-01
The mechanical anisotropy of an explosive welding composite plate made of 304 stainless steel/245 steel was studied through shear experiments performed on explosively welded wavy interfaces along several orientation angles. The results indicated that the strength and the fracture energy of samples significantly varied with the orientation angles. The fracture surfaces of all samples were observed using a scanning electron microscope and through three-dimensional structure microscopy. The periodic features of all the fracture surfaces were clearly shown in different fracture modes. The fractal dimension of the fracture surfaces was calculated based on the fractal geometry by the box-counting method in MATLAB. The cohesive element model was used to analyze the fracture energy according to the physical dependence of the fractal dimension on thermodynamic entropy and interface separation energy. The fracture energy was an exponential function of the fractal dimension value, which was in good agreement with the experimental results. All results were validated for effective use in the application of anisotropy analysis to the welded interface and structural optimization of explosively welded composite plates.
UV inactivation of pathogenic and indicator microorganisms
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chang, J.C.; Ossoff, S.F.; Lobe, D.C.
1985-06-01
Survival was measured as a function of the dose of germicidal UV light for the bacteria Escherichia coli, Salmonella typhi, Shigella sonnei, Streptococcus faecalis, Staphylococcus aureus, and Bacillus subtilis spores, the enteric viruses poliovirus type 1 and simian rotavirus SA11, the cysts of the protozoan Acanthamoeba castellanii, as well as for total coliforms and standard plate count microorganisms from secondary effluent. The doses of UV light necessary for a 99.9% inactivation of the cultured vegetative bacteria, total coliforms, and standard plate count microorganisms were comparable. However, the viruses, the bacterial spores, and the amoebic cysts required about 3 to 4more » times, 9 times, and 15 times, respectively, the dose required for E. coli. These ratios covered a narrower relative dose range than that previously reported for chlorine disinfection of E. coli, viruses, spores, and cysts.« less
Knight, M T; Newman, M C; Benzinger, M J; Neufang, K L; Agin, J R; McAllister, J S; Ramos, M
1997-01-01
A collaborative study was performed involving 18 laboratories and 6 food types to compare 3M Petrifilm yeast and mold count plates with the method described in the U.S. Food and Drug Administration's Bacteriological Analytical Manual. Four species of mold and 2 species of yeast were used to inoculate the following foods: hot dogs, corn meal, ketchup, orange juice, yogurt, and cake mix. Each collaborator received 15 samples of each food type: 5 low-level inoculations, 5 high-level inoculations, and 5 uninoculated samples. There was no significant difference between the means of the 2 methods for any product or inoculation level. The Petrifilm yeast and mold count plate method for enumeration of yeasts and molds in foods has been adopted first action by AOAC INTERNATIONAL.
Stewart, M H; Wolfe, R L; Means, E G
1990-01-01
Bacteriological analyses were performed on the effluent from a conventional water treatment pilot plant in which granular activated carbon (GAC) had been used as the final process to assess the impact of GAC on the microbial quality of the water produced. Samples were collected twice weekly for 160 days from the effluents of six GAC columns, each of which used one of four different empty-bed contact times (7.5, 15, 30, and 60 min). The samples were analyzed for heterotrophic plate counts and total coliforms. Effluent samples were also exposed to chloramines and free chlorine for 60 min (pH 8.2, 23 degrees C). Bacterial identifications were performed on the disinfected and nondisinfected effluents. Additional studies were conducted to assess the bacteriological activity associated with released GAC particles. The results indicated that heterotrophic plate counts in the effluents from all columns increased to 10(5) CFU/ml within 5 days and subsequently stabilized at 10(4) CFU/ml. The heterotrophic plate counts did not differ at different empty-bed contact times. Coliforms (identified as Enterobacter spp.) were recovered from the nondisinfected effluent on only two occasions. The disinfection results indicated that 1.5 mg of chloramines per liter inactivated approximately 50% more bacteria than did 1.0 mg of free chlorine per liter after 1 h of contact time. Chloramines and chlorine selected for the development of different bacterial species--Pseudomonas spp. and Flavobacterium spp., respectively.(ABSTRACT TRUNCATED AT 250 WORDS) PMID:2082828
J.D. Podgwaite; R.B. Bruen; M. Shapiro
1983-01-01
Samples of a gypsy moth nucleopolyhedrosis virus product, Gypchek®, were taken each day during a 100-day production run and monitored for the presence of pathogenic bacteria and fungi. The standard plate count/g of product was 5.97 ± 1.51 x 108 over the 100-day period, while the sporulating bacteria count was 3.81 ± 1.21 x 106...
Aerosol, a health hazard during ultrasonic scaling: A clinico-microbiological study.
Singh, Akanksha; Shiva Manjunath, R G; Singla, Deepak; Bhattacharya, Hirak S; Sarkar, Arijit; Chandra, Neeraj
2016-01-01
Ultrasonic scaling is a routinely used treatment to remove plaque and calculus from tooth surfaces. These scalers use water as a coolant which is splattered during the vibration of the tip. The splatter when mixed with saliva and plaque of the patients causes the aerosol highly infectious and acts as a major risk factor for transmission of the disease. In spite of necessary protection, sometimes, the operator might get infected because of the infectious nature of the splatter. To evaluate the aerosol contamination produced during ultrasonic scaling by the help of microbiological analysis. This clinico-microbiological study consisted of twenty patients. Two agar plates were used for each patient; the first was kept at the center of the operatory room 20 min before the treatment while the second agar plate was kept 40 cm away from the patient's chest during the treatment. Both the agar plates were sent for microbiological analysis. The statistical analysis was done with the help of STATA 11.0 (StataCorp. 2013. Stata Statistical Software, Release 13. College Station, TX: StataCorp LP, 4905 Lakeway Drive College Station, Texas, USA). Statistical software was used for data analysis and the P < 0.001 was considered to be statistically significant. The results for bacterial count were highly significant when compared before and during the treatment. The Gram staining showed the presence of Staphylococcus and Streptococcus species in high numbers. The aerosols and splatters produced during dental procedures have the potential to spread infection to dental personnel. Therefore, proper precautions should be taken to minimize the risk of infection to the operator.
[Chromosome analysis of bulls in relation to disorders of sexual activity].
Staník, J; Izariková, A
1984-05-01
Chromosomal analysis was used for the examination of 16 bulls of different breeds from the Milhostov breeding station. The examined bulls exhibited disorders of sexual activity (disorders of spermiogenesis, aspermia, bad quality of semen, hypoplasia of testes, etc.). The examination was performed by the method after Moorhead et al. (1960) modified by Lojda et al. (1974): metaphase plates were evaluated microscopically (100 X 12) and from photos. The chromosomes were counted by means of the counting documator (from film negatives) and from photos. A card was prepared for each animal. Hyposomy (11 sires--68.75%) and hyperploidy (10 sires--62.5%) were found to be the most frequent numerical aberrations, followed by polysomy (4 sires--25.0%) and other aneuploidies (one case--6.2%). As to structural defects, breaks occurred in 14 sires (87.5%), bichromatid breaks in five sires (31.25%) and breaks on sexual chromosomes in three sires (18.75%). Centric fusion was observed in one case (6.25%), association in two cases (12.5%) and mixed aberrations in four cases (25.00%).
NASA Astrophysics Data System (ADS)
Zheng, Xiaochun; Peng, Yankun; Li, Yongyu; Chao, Kuanglin; Qin, Jianwei
2017-05-01
The plate count method is commonly used to detect the total viable count (TVC) of bacteria in pork, which is timeconsuming and destructive. It has also been used to study the changes of the TVC in pork under different storage conditions. In recent years, many scholars have explored the non-destructive methods on detecting TVC by using visible near infrared (VIS/NIR) technology and hyperspectral technology. The TVC in chilled pork was monitored under high oxygen condition in this study by using hyperspectral technology in order to evaluate the changes of total bacterial count during storage, and then evaluate advantages and disadvantages of the storage condition. The VIS/NIR hyperspectral images of samples stored in high oxygen condition was acquired by a hyperspectral system in range of 400 1100nm. The actual reference value of total bacteria was measured by standard plate count method, and the results were obtained in 48 hours. The reflection spectra of the samples are extracted and used for the establishment of prediction model for TVC. The spectral preprocessing methods of standard normal variate transformation (SNV), multiple scatter correction (MSC) and derivation was conducted to the original reflectance spectra of samples. Partial least squares regression (PLSR) of TVC was performed and optimized to be the prediction model. The results show that the near infrared hyperspectral technology based on 400-1100nm combined with PLSR model can describe the growth pattern of the total bacteria count of the chilled pork under the condition of high oxygen very vividly and rapidly. The results obtained in this study demonstrate that the nondestructive method of TVC based on NIR hyperspectral has great potential in monitoring of edible safety in processing and storage of meat.
Efficacy of hypobromous acid as a hide-on carcass antimicrobial intervention.
Schmidt, John W; Wang, Rong; Kalchayanand, Norasak; Wheeler, Tommy L; Koohmaraie, Mohammad
2012-05-01
Escherichia coli O157:H7 and Salmonella on cattle hides at slaughter are the main source of beef carcass contamination by these foodborne pathogens during processing. Hypobromous acid (HOBr) has been approved for various applications in meat processing, but the efficacy of HOBr as a hide antimicrobial has not been determined. In this study, the antimicrobial properties of HOBr were determined by spraying cattle hides at either of two concentrations, 220 or 500 ppm. Treatment of hides with 220 ppm of HOBr reduced the prevalence of E. coli O157:H7 on hides from 25.3 to 10.1% (P < 0.05) and reduced the prevalence of Salmonella from 28.3 to 7.1% (P < 0.05). Treatment of hides with 500 ppm of HOBr reduced (P < 0.05) the prevalence of E. coli O157:H7 on hides from 21.2 to 10.1% and the prevalence of Salmonella from 33.3 to 8.1%. The application of 220 ppm of HOBr reduced (P < 0.05) aerobic plate counts, total coliform counts, and E. coli counts on hides by 2.2 log CFU/ 100 cm(2). The use of 500 ppm of HOBr resulted in reductions (P < 0.05) of aerobic plate counts, total coliform counts, and E. coli counts by 3.3, 3.7, and 3.8 log CFU/100 cm(2), respectively, demonstrating that the use of higher concentrations of HOBr on hides resulted in additional antimicrobial activity. These results indicate that the adoption of a HOBr hide wash will reduce hide concentrations of spoilage bacteria and pathogen prevalence, resulting in a lower risk of carcass contamination.
Feasibility study for epidemic prevention and control in a regional hospital.
Chen, Yung-Liang; Yeh, Ming-Yang; Huang, Shau-Yen; Liu, Chi-Ming; Sun, Chi-Chen; Lu, Hsu-Feng; Chiu, Tsan-Hung; Hsia, Te-Chun; Chung, Jing-Gung
2012-03-01
Epidemic prevention policies in hospitals address issues such as, indoor air quality control, cleanliness of medical staff clothing and employee hand-washing procedures. Our hospital employed Bio-Kil to treat air-conditioning filters and nursing staff uniforms. We also assessed the efficacy of different detergents. Using Bio-Kil technology, the mean bacterial count in the air was reduced from 108.8 CFU/h/plate (n=420) to 68.6 CFU/h/plate (n=630). On the lower hems of the Bio-Kil-treated gowns, the mean bacterial count was 1,201 CFU/100 cm(2), markedly lower than the bacterial count of 7,753 CFU/100 cm(2), found on the parts of the gowns not treated with Bio-Kil (p=0.0401). On the cuffs of sleeves treated with Bio-Kil, the mean count was 1,165 CFU/100 cm(2), markedly lower than that of 2,131 CFU/100 cm(2), found on the cuffs not treated with Bio-Kil (p=0.0073). With regard to the mean bacterial eradication rates of antimicrobial solutions, Steridal Solution, 75% alcohol and Bio-Kil (3rd generation) were shown to be the most effective, with rates exceeding 80%. Hibiscrub with paper towels and Fresh Protect Skin were the second most effective. Bio-Kil (1st generation), tap water with paper towels, liquid hand soap with paper towels and ozone water were the least effective. One important observation was that hand-washing without the use of paper towels increased the bacterial count by as much as 84% . Bio-Kil is effective in reducing bacterial counts in the air, on nursing staff uniforms and is an effective detergent.
Sundaram, Meenakshi; Nayak, Ullal Anand; Ramalingam, Krishnakumar; Reddy, Venugopal; Rao, Arun Prasad; Mathian, Mahesh
2013-01-01
Aims: The aim of this study is to find out whether Oratest can be used as a diagnostic tool in assessing the caries activity by evaluating its relationship to the existing caries status and the salivary streptococcus mutans level. Materials and Methods: The study sample consists of 90 students divided into two groups. Group I (test group) and Group II (control group) consisting of 30 children for control group and 60 children for test group. The sampling of unstimulated saliva for the estimation of streptococcus mutans was done as per the method suggested by Kohler and Bratthall. The plates were then incubated. Rough surface colonies were identified as streptococcus mutans on a pre-determined area of the tip (approximately 1.5 cm2) were counted for each side of spatula pressed against mitis salivarius bacitracin agar using digital colony counter. The results were expressed in colony forming units (CFU). Oratest was carried out in the same patients after the collection of salivary sample for the microbiological method to evaluate the relationship between the two tests. Statistical Analysis Used: The tests used were ANOVA, Pearson Chi-square test, Pearson′s correlation analysis, Mann-Whitney U test and Student′s independent t-test. Results: In the control group and test group, when the streptococcus mutans count (CFU) and Oratest time (minutes) were correlated using Pearson′s correlation analysis, the streptococcus mutans counts was found to be in a statistically significant negative linear relationship with the Oratest time. When the caries status of the children, participated in the test group were correlated with mutans count (CFU) and Oratest time, caries status were found to be in a statistically significant positive linear relationship with streptococcus mutans count and in a significant negative linear relationship with Oratest time. Conclusions: The test proved to be a simple, inexpensive and rapid technique for assessing caries activity since a significant relationship exists clinically with caries status and microbiologically with the streptococcus mutans count of the individual. PMID:23946577
Calorie count - sodas and energy drinks
... Accessed May 11, 2016. United States Department of Agriculture website. ChooseMyPlate.gov. Make better beverage choices. www. ... Accessed May 11, 2016. United States Department of Agriculture. National nutrient database for standard reference. Release 28. ...
7 CFR 58.653 - Microbiological requirements for sherbet.
Code of Federal Regulations, 2011 CFR
2011-01-01
... requirements for sherbet. The finished product shall contain not more than 50,000 bacteria per gram as determined by the standard plate count and shall contain not more than 10 coliform organisms per gram in...
7 CFR 58.653 - Microbiological requirements for sherbet.
Code of Federal Regulations, 2010 CFR
2010-01-01
... requirements for sherbet. The finished product shall contain not more than 50,000 bacteria per gram as determined by the standard plate count and shall contain not more than 10 coliform organisms per gram in...
7 CFR 58.653 - Microbiological requirements for sherbet.
Code of Federal Regulations, 2013 CFR
2013-01-01
... requirements for sherbet. The finished product shall contain not more than 50,000 bacteria per gram as determined by the standard plate count and shall contain not more than 10 coliform organisms per gram in...
Comprehensive System-Based Architecture for an Integrated High Energy Laser Test Bed
2015-03-01
76 4. Comparison of Sensors ................................................................76 B. TRANSMISSION...81 b. Photometers .......................................................................84 4. Comparison of Sensors ...88 a. Flat Plate Target Boards, Ablatives, and Acrylite ...........88 b. Photon-Counting Sensors
Microchannel plate EUV detectors for the Extreme Ultraviolet Explorer
NASA Technical Reports Server (NTRS)
Siegmund, O. H. W.; Malina, R. F.; Coburn, K.; Werthimer, D.
1984-01-01
The design and operating characteristics of the prototype imaging microchannel plate (MCP) detector for the Extreme Ultraviolet Explorer (EUVE) Satellite are discussed. It is shown that this detector has achieved high position resolution performance (greater than 512 x 512 pixels) and has low (less than one percent) image distortion. In addition, the channel plate scheme used has tight pulse height distributions (less than 40 percent FWHM) for UV radiation and displays low (less than 0.2 cnt/sq cm-s) dark background counting rates. Work that has been done on EUV filters in relation to the envisaged filter and photocathode complement is also described.
Radiation-hard ceramic Resistive Plate Chambers for forward TOF and T0 systems
NASA Astrophysics Data System (ADS)
Akindinov, A.; Dreyer, J.; Fan, X.; Kämpfer, B.; Kiselev, S.; Kotte, R.; Garcia, A. Laso; Malkevich, D.; Naumann, L.; Nedosekin, A.; Plotnikov, V.; Stach, D.; Sultanov, R.; Voloshin, K.
2017-02-01
Resistive Plate Chambers with ceramic electrodes are the main candidates for a use in precise multi-channel timing systems operating in high-radiation conditions. We report the latest R&D results on these detectors aimed to meet the requirements of the forward T0 counter at the CBM experiment. RPC design, gas mixture, limits on the bulk resistivity of ceramic electrodes, efficiency, time resolution, counting rate capabilities and ageing test results are presented.
NASA Astrophysics Data System (ADS)
Zawisky, M.; Hameed, F.; Dyrnjaja, E.; Springer, J.
2008-03-01
Imaging techniques provide an indispensable tool for investigation of materials. Neutrons, due to their specific properties, offer a unique probe for many aspects of condensed matter. Neutron imaging techniques present a challenging experimental task, especially at a low power research reactor. The Atomic Institute with a 250 kW TRIGA MARK II reactor looks back at a long tradition in neutron imaging. Here we report on the advantages gained in a recent upgrade of the imaging instrument including the acquisition of a thin-plate scintillation detector, a single counting micro-channel plate detector, and an imaging plate detector in combination with a high resolution scanner. We analyze the strengths and limitations of each detector in the field of neutron radiography and tomography, and demonstrate that high resolution digitized imaging down to the 50 μm scale can be accomplished with weak beam intensities of 1.3×10 5 n/cm 2 s, if appropriate measures are taken for the inevitable extension of measurement times. In a separate paper we will present some promising first results from the fields of engineering and geology.
SkICAT: A cataloging and analysis tool for wide field imaging surveys
NASA Technical Reports Server (NTRS)
Weir, N.; Fayyad, U. M.; Djorgovski, S. G.; Roden, J.
1992-01-01
We describe an integrated system, SkICAT (Sky Image Cataloging and Analysis Tool), for the automated reduction and analysis of the Palomar Observatory-ST ScI Digitized Sky Survey. The Survey will consist of the complete digitization of the photographic Second Palomar Observatory Sky Survey (POSS-II) in three bands, comprising nearly three Terabytes of pixel data. SkICAT applies a combination of existing packages, including FOCAS for basic image detection and measurement and SAS for database management, as well as custom software, to the task of managing this wealth of data. One of the most novel aspects of the system is its method of object classification. Using state-of-theart machine learning classification techniques (GID3* and O-BTree), we have developed a powerful method for automatically distinguishing point sources from non-point sources and artifacts, achieving comparably accurate discrimination a full magnitude fainter than in previous Schmidt plate surveys. The learning algorithms produce decision trees for classification by examining instances of objects classified by eye on both plate and higher quality CCD data. The same techniques will be applied to perform higher-level object classification (e.g., of galaxy morphology) in the near future. Another key feature of the system is the facility to integrate the catalogs from multiple plates (and portions thereof) to construct a single catalog of uniform calibration and quality down to the faintest limits of the survey. SkICAT also provides a variety of data analysis and exploration tools for the scientific utilization of the resulting catalogs. We include initial results of applying this system to measure the counts and distribution of galaxies in two bands down to Bj is approximately 21 mag over an approximate 70 square degree multi-plate field from POSS-II. SkICAT is constructed in a modular and general fashion and should be readily adaptable to other large-scale imaging surveys.
Protective isolation in single-bed rooms: studies in a modified hospital ward
Ayliffe, G. A. J.; Collins, B. J.; Lowbury, E. J. L.; Wall, Mary
1971-01-01
Studies were made in a modified hospital ward containing 19 beds, 14 of them in the open ward, one in a window-ventilated side-room, two in rooms with partial-recirculation ventilators giving 7-10 air changes per hour, and two in self-contained isolation suites with plenum ventilation (20 air changes per hour), ultra-violet (UV) barriers at doorways and airlocks. Preliminary tests with aerosols of tracer bacteria showed that few bacteria entered the plenum or recirculation-ventilated rooms. Bacteria released inside mechanically ventilated cubicles escaped into the corridor, but this transfer was reduced by the presence of an airlock. UV barriers at the entrance to the airlock and the cubicle reduced the transfer of bacteria from cubicle to corridor. During a period of 4 years while the ward was in use for surgical and gynaecological patients, the incidence of post-operative sepsis and colonization of wounds by multiple-resistant Staphylococcus aureus was lower (though not significantly lower) in the plenum-ventilated rooms than in the open ward, the recirculator-ventilated cubicles and the window-ventilated cubicles. Nasal acquisition of multiple-resistant Staph. aureus was significantly less common in the plenum-ventilated than in the recirculator-ventilated cubicles and in the other areas. Mean counts of bacteria on settle-plates were significantly lower in the plenum-ventilated cubicles than in the other areas; mean settle-plate counts in the recirculator-ventilated cubicles were significantly lower than in the open ward and in the window-ventilated side-room; similar results were shown by slit-sampling of air. Mean settle-plate counts were significantly lower in all areas when the ward was occupied by female patients. Staph. aureus was rarely carried by air from plenum-ventilated or other cubicles to the open ward, or from the open ward to the cubicles; though staphylococci were transferred from one floor area to another, they did not appear to be redispersed into the air in sufficient numbers to infect the patients. Ultra-violet irradiation caused a significant reduction in the total and staphylococcal counts from the floors of airlocks, and a significant reduction of total counts in the air. PMID:5289715
High event rate ROICs (HEROICs) for astronomical UV photon counting detectors
NASA Astrophysics Data System (ADS)
Harwit, Alex; France, Kevin; Argabright, Vic; Franka, Steve; Freymiller, Ed; Ebbets, Dennis
2014-07-01
The next generation of astronomical photocathode / microchannel plate based UV photon counting detectors will overcome existing count rate limitations by replacing the anode arrays and external cabled electronics with anode arrays integrated into imaging Read Out Integrated Circuits (ROICs). We have fabricated a High Event Rate ROIC (HEROIC) consisting of a 32 by 32 array of 55 μm square pixels on a 60 μm pitch. The pixel sensitivity (threshold) has been designed to be globally programmable between 1 × 103 and 1 × 106 electrons. To achieve the sensitivity of 1 × 103 electrons, parasitic capacitances had to be minimized and this was achieved by fabricating the ROIC in a 65 nm CMOS process. The ROIC has been designed to support pixel counts up to 4096 events per integration period at rates up to 1 MHz per pixel. Integration time periods can be controlled via an external signal with a time resolution of less than 1 microsecond enabling temporally resolved imaging and spectroscopy of astronomical sources. An electrical injection port is provided to verify functionality and performance of each ROIC prior to vacuum integration with a photocathode and microchannel plate amplifier. Test results on the first ROICs using the electrical injection port demonstrate sensitivities between 3 × 103 and 4 × 105 electrons are achieved. A number of fixes are identified for a re-spin of this ROIC.
Improved methods for the enumeration of heterotrophic bacteria in bottled mineral waters.
Ramalho, R; Cunha, J; Teixeira, P; Gibbs, P A
2001-03-01
At this time the European Union regulations require that the heterotrophic plate counts (HPC) of mineral waters be assessed at two recovery temperatures: 22 degrees C for 72 h and 37 degrees C for 24 h. This procedure is time consuming and expensive. Development of new rapid methods for microbiological assessment of the microbial flora in the bottled water is an industry-driven need. The objectives of this work were to develop a method for the HPC that utilises only one recovery temperature and one incubation period and evaluate the use of, the LIVE/DEAD(R) BacLight Bacterial Viability Kit, 5-cyano-2,3-ditotyl tetrazolium chloride (CTC) and impedance methods to enumerate viable bacteria in bottled mineral water. Results showed that incubation at 30 degrees C could be used instead of incubation at 22 degrees C and 37 degrees C. Good correlation exists between counts at 30 degrees C and counts at 22 degrees C (r>0.90) and all the pathogens important in mineral water analyses grow similarly at 30 degrees C and 37 degrees C during 24 h. It was demonstrated that impedance methods might be useful to the mineral water industry as a rapid indicator of microbiological quality of the water. Results obtained with BacLight and CTC were similar to those obtained with plate counts.
Wang, Yongli; Li, Feng; Zhuang, Hong; Li, Lianghao; Chen, Xiao; Zhang, Jianhao
2015-03-01
Effects of plant polyphenols (tea polyphenol [TP], grape seed extract [GSE], and gingerol) and α-tocopherol on physicochemical parameters, microbiological counts, and biogenic amines were determined in dry-cured bacons at the end of ripening. Results showed that plant polyphenols and α-tocopherol significantly decreased pH, thiobarbituric acid reactive substances content, and total volatile basic nitrogen (TVBN) compared with the control (P < 0.05). Microbial counts and biogenic amine contents in dry-cured bacons were affected by plant polyphenols or α-tocopherol, with TP being the most effective (P < 0.05) in reducing aerobic plate counts, Enterobacteriaceae, Micrococcaceae, yeast, and molds, as well as in inhibiting formation of putrescine, cadaverine, tyramine, and spermine. Principal component analysis indicated that the first 2 principal components (PC) explained about 85.5% of the total variation. PC1 was related with physicochemical factors, parts of biogenic amines, and spoilage microorganisms, whereas PC2 grouped the TVBN, tyramine, 2-phenylethylamine, yeast, and molds. These findings suggest that plant polyphenols, especially TP, could be used to process dry-cured bacons to improve the quality and safety of finished products. © 2015 Institute of Food Technologists®
Loske, Achim M; Tello, Elba M; Vargas, Susana; Rodriguez, Rogelio
2014-08-01
To determine the concentration of bacteria in a sample is important in the food industry, medicine and biotechnology. A disadvantage of the plate-counting method is that a microorganism colony could arise from one cell or from many cells. The other standard methodology, known as optical density determination, is based on the turbidity of a suspension and registers all bacteria, dead and alive. In this article, dynamic light scattering is proposed as a fast and reliable method to determine bacterial viability and, consequently, time evolution. Escherichia coli was selected because this microorganism is well known and easy to handle. A correlation between the data from these three techniques was obtained. We were able to calculate the growth rate, usually determined by plate counting or optical density measurement, using dynamic light scattering and to predict bacterial behavior. An analytical relationship between the colony forming units and the light scattered intensity was also deduced.
Ahmed, Asm Sabbir; Hauck, Barry; Kramer, Gary H
2012-08-01
This study described the performance of an array of high-purity Germanium detectors, designed with two different end cap materials-steel and carbon fibre. The advantages and disadvantages of using this detector type in the estimation of the minimum detectable activity (MDA) for different energy peaks of isotope (152)Eu were illustrated. A Monte Carlo model was developed to study the detection efficiency for the detector array. A voxelised Lawrence Livermore torso phantom, equipped with lung, chest plates and overlay plates, was used to mimic a typical lung counting protocol with the array of detectors. The lung of the phantom simulated the volumetric source organ. A significantly low MDA was estimated for energy peaks at 40 keV and at a chest wall thickness of 6.64 cm.
Quality control of fifteen probiotic products containing Saccharomyces boulardii.
Vanhee, L M E; Goemé, F; Nelis, H J; Coenye, T
2010-11-01
The yeast Saccharomyces boulardii is used as a probiotic for the prevention and treatment of diarrhoea. In this study, the quality of 15 probiotic products containing S. boulardii was verified. Using microsatellite typing, the identity of all Saccharomyces strains in the products was confirmed as S. boulardii. Additionally, solid-phase cytometry (SPC) and a plate method were used to enumerate S. boulardii cells. SPC was not only able to produce results more rapidly than plating (4h compared to 48h) but the cell counts obtained with SPC were significantly higher than the plate counts. Finally, we found that <1% of the S. boulardii cells survived 120min in gastric conditions and storage for 3months at 40°C with 75% relative humidity. We developed a SPC method for the quantification of viable S. boulardii cells in probiotics. Additionally, we demonstrated that gastric conditions and storage have a marked effect on the viability of the yeast cells. To our knowledge, this is the first time SPC is used for the quality control of probiotics with S. boulardii. Additionally, we demonstrated the need for gastric protection and accurate storage. © 2010 The Authors. Journal of Applied Microbiology © 2010 The Society for Applied Microbiology.
A Novel 96well-formatted Micro-gap Plate Enabling Drug Response Profiling on Primary Tumour Samples
NASA Astrophysics Data System (ADS)
Ma, Wei-Yuan; Hsiung, Lo-Chang; Wang, Chen-Ho; Chiang, Chi-Ling; Lin, Ching-Hung; Huang, Chiun-Sheng; Wo, Andrew M.
2015-04-01
Drug-based treatments are the most widely used interventions for cancer management. Personalized drug response profiling remains inherently challenging with low cell count harvested from tumour sample. We present a 96well-formatted microfluidic plate with built-in micro-gap that preserves up to 99.2% of cells during multiple assay/wash operation and only 9,000 cells needed for a single reagent test (i.e. 1,000 cells per test spot x 3 selected concentration x triplication), enabling drug screening and compatibility with conventional automated workstations. Results with MCF7 and MDA-MB-231 cell lines showed that no statistical significance was found in dose-response between the device and conventional 96-well plate control. Primary tumour samples from breast cancer patients tested in the device also showed good IC50 prediction. With drug screening of primary cancer cells must consider a wide range of scenarios, e.g. suspended/attached cell types and rare/abundant cell availability, the device enables high throughput screening even for suspended cells with low cell count since the signature microfluidic cell-trapping feature ensures cell preservation in a multiple solution exchange protocol.
Mwanamoki, Paola M; Devarajan, Naresh; Thevenon, Florian; Atibu, Emmanuel K; Tshibanda, Joseph B; Ngelinkoto, Patience; Mpiana, Pius T; Prabakar, Kandasamy; Mubedi, Josué I; Kabele, Christophe G; Wildi, Walter; Poté, John
2014-10-01
This study was conducted to assess potential human health risks presented by pathogenic bacteria in a protected multi-use lake-reservoir (Lake Ma Vallée) located in west of Kinshasa, Democratic Republic of Congo (DRC). Water and surface sediments from several points of the Lake were collected during summer. Microbial analysis was performed for Escherichia coli, Enterococcus (ENT), Pseudomonas species and heterotrophic plate counts. PCR amplification was performed for the confirmation of E. coli, ENT, Pseudomonas spp. and Pseudomonas aeruginosa isolated from samples. The results reveal low concentration of bacteria in water column of the lake, the bacterial quantification results observed in this study for the water column were below the recommended limits, according to WHO and the European Directive 2006/7/CE, for bathing water. However, high concentration of bacteria was observed in the sediment samples; the values of 2.65 × 10(3), 6.35 × 10(3), 3.27 × 10(3) and 3.60 × 10(8) CFU g(-1) of dry sediment for E. coli, ENT, Pseudomonas spp. and heterotrophic plate counts, respectively. The results of this study indicate that sediments of the Lake Ma Vallée can constitute a reservoir of pathogenic microorganisms which can persist in the lake. Possible resuspension of faecal indicator bacteria and pathogens would affect water quality and may increase health risks to the population during recreational activities. Our results indicate that the microbial sediment analysis provides complementary and important information for assessing sanitary quality of surface water under tropical conditions.
Davis, Reeta; Irudayaraj, Joseph; Reuhs, Bradley L; Mauer, Lisa J
2010-08-01
FT-IR spectroscopy methods for detection, differentiation, and quantification of E. coli O157:H7 strains separated from ground beef were developed. Filtration and immunomagnetic separation (IMS) were used to extract live and dead E. coli O157:H7 cells from contaminated ground beef prior to spectral acquisition. Spectra were analyzed using chemometric techniques in OPUS, TQ Analyst, and WinDAS software programs. Standard plate counts were used for development and validation of spectral analyses. The detection limit based on a selectivity value using the OPUS ident test was 10(5) CFU/g for both Filtration-FT-IR and IMS-FT-IR methods. Experiments using ground beef inoculated with fewer cells (10(1) to 10(2) CFU/g) reached the detection limit at 6 h incubation. Partial least squares (PLS) models with cross validation were used to establish relationships between plate counts and FT-IR spectra. Better PLS predictions were obtained for quantifying live E. coli O157:H7 strains (R(2)> or = 0.9955, RMSEE < or = 0.17, RPD > or = 14) and different ratios of live and dead E. coli O157:H7 cells (R(2)= 0.9945, RMSEE = 2.75, RPD = 13.43) from ground beef using Filtration-FT-IR than IMS-FT-IR methods. Discriminant analysis and canonical variate analysis (CVA) of the spectra differentiated various strains of E. coli O157:H7 from an apathogenic control strain. CVA also separated spectra of 100% dead cells separated from ground beef from spectra of 0.5% live cells in the presence of 99.5% dead cells of E. coli O157:H7. These combined separation and FT-IR methods could be useful for rapid detection and differentiation of pathogens in complex foods.
Kim, Do-Kyun; Kim, Soo-Ji; Kang, Dong-Hyun
2015-07-01
This study was undertaken to compare the effect of the spindle and stomacher for detaching microorganisms from fresh vegetables. The spindle is an apparatus for detaching microorganisms from food surfaces, which was developed in our laboratory. When processed with the spindle, food samples were barely disrupted, the original shape was maintained, and the diluent was clear, facilitating further detection analysis more easily than with stomacher treatment. The four-section spindle consists of four sample bag containers (A, B, C, and D) to economize time and effort by simultaneously processing four samples. The aerobic plate counts (APC) of 50 fresh vegetable samples were measured following spindle and stomacher treatment. Correlations between the two methods for each section of the spindle and stomacher were very high (R(2) = 0.9828 [spindle compartment A; Sp A], 0.9855 [Sp B], 0.9848 [Sp C], and 0.9851 [Sp D]). One-tenth milliliter of foodborne pathogens suspensions was inoculated onto surfaces of food samples, and ratios of spindle-to-stomacher enumerations were close to 1.00 log CFU/g between every section of the spindle and stomacher. One of the greatest features of the spindle is that it can treat large-sized samples that exceed 200 g. Uncut whole apples, green peppers, potatoes, and tomatoes were processed by the spindle and by hand massaging by 2 min. Large-sized samples were also assayed for aerobic plate count and recovery of the three foodborne pathogens, and the difference between each section of the spindle and hand massaging was not significant (P > 0.05). This study demonstrated that the spindle apparatus can be an alternative device for detaching microorganisms from all fresh vegetable samples for microbiological analysis by the food processing industry.
The effect of an antibacterial washing-up liquid in reducing dishwater aerobic plate counts.
Holah, J T; Hall, K E
2006-05-01
To assess any significant differences in the aerobic plate count (APC) of catering dishwaters following the use of a traditional, nonantibacterial or an antibacterial washing-up liquid. A dishwashing trial was undertaken within a commercial restaurant of 6 weeks duration (3 weeks with each washing-up liquid in a randomized, weekly pattern). Five replicate samples were taken from the dishwater at the end of the washing-up operation, on three separate occasions each day corresponding to mid-morning, lunchtime and mid-afternoon meal preparations. The antibacterial product was shown to significantly reduce the APC by an average log10 reduction of 1.81 CFU ml(-1) (98.5%) as compared with the traditional product. APC were lower for each of the three weekly time periods for the antibacterial product. Continued use of the antibacterial product did not decrease the APC of the dishwater, though with the traditional product, dishwater counts increased throughout the trial week. Antibacterial washing-up liquids, with proven activity in controlling levels of microorganisms in dishwaters, could play a significant role in reducing the risk of cross-contamination between washed articles during washing-up operations.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Andre, M.; Hugot, G.
A procedure is described for the detection of alpha -emitting contaminants of the respiratory tract. The method is useful when contamination from inhaled Pu/sup 239/ is suspected. Sputum, collected early in the morning, is dissolved in mineral acids and then evaporated on a stainiess steel plate. Radioautograms are prepared by placing the plate in contact with a nuclear emulsion. The number of tracks appearing after 24 and 48 hrs and 7 days is counted. The results are useful in estimating internal contamination and in following removal from the respiratory tract. (C.H.)
The Sydney University PAPA camera
NASA Astrophysics Data System (ADS)
Lawson, Peter R.
1994-04-01
The Precision Analog Photon Address (PAPA) camera is a photon-counting array detector that uses optical encoding to locate photon events on the output of a microchannel plate image intensifier. The Sydney University camera is a 256x256 pixel detector which can operate at speeds greater than 1 million photons per second and produce individual photon coordinates with a deadtime of only 300 ns. It uses a new Gray coded mask-plate which permits a simplified optical alignment and successfully guards against vignetting artifacts.
Bare below elbows: does this policy affect handwashing efficacy and reduce bacterial colonisation?
Burger, A; Wijewardena, C; Clayson, S; Greatorex, RA
2010-01-01
INTRODUCTION UK Department of Health guidelines recommend that clinical staff are ‘bare below the elbows’. There is a paucity of evidence to support this policy. One may hypothesise that absence of clothing around wrists facilitates more effective handwashing: this study aims to establish whether dress code affects bacterial colonisation before and after handwashing. SUBJECTS AND METHODS Sixty-six clinical staff volunteered to take part in the study, noting whether they were bare below the elbows (BBE) or not bare (NB). Using a standardised technique, imprints of left and right fingers, palms, wrists and forearms were taken onto mini agar plates. Imprints were repeated after handwashing. After incubation, colonies per plate were counted, and subcultures taken. RESULTS Thirty-eight staff were BBE and 28 were not. A total of 1112 plates were cultured. Before handwashing there was no significant difference in number of colonies between BBE and NB groups (Mann–Whitney, P < 0.05). Handwashing reduced the colony count, with greatest effect on fingers, palms and dominant wrists (t-test, P < 0.05). Comparing the two groups again after handwashing revealed no significant difference (Mann–Whitney, P < 0.05). Subcultures revealed predominantly skin flora. CONCLUSIONS There was a large variation in number of colonies cultured. Handwashing resulted in a statistically significant reduction in colony count on fingers, palms and dominant wrist regardless of clothing. We conclude that handwashing produces a significant reduction in number of bacterial colonies on staff hands, and that clothing that is not BBE does not impede this reduction. PMID:20727253
Relationship between salivary flow rates and Candida counts in subjects with xerostomia.
Torres, Sandra R; Peixoto, Camila Bernardo; Caldas, Daniele Manhães; Silva, Eline Barboza; Akiti, Tiyomi; Nucci, Márcio; de Uzeda, Milton
2002-02-01
This study evaluated the relationship between salivary flow and Candida colony counts in the saliva of patients with xerostomia. Sialometry and Candida colony-forming unit (CFU) counts were taken from 112 subjects who reported xerostomia in a questionnaire. Chewing-stimulated whole saliva was collected and streaked in Candida plates and counted in 72 hours. Species identification was accomplished under standard methods. There was a significant inverse relationship between salivary flow and Candida CFU counts (P =.007) when subjects with high colony counts were analyzed (cutoff point of 400 or greater CFU/mL). In addition, the median sialometry of men was significantly greater than that of women (P =.003), even after controlling for confounding variables like underlying disease and medications. Sjögren's syndrome was associated with low salivary flow rate (P =.007). There was no relationship between the median Candida CFU counts and gender or age. There was a high frequency (28%) of mixed colonization. Candida albicans was the most frequent species, followed by C parapsilosis, C tropicalis, and C krusei. In subjects with high Candida CFU counts there was an inverse relationship between salivary flow and Candida CFU counts.
Rivas, Lucia; Dykes, Gary A; Fegan, Narelle
2007-04-01
Attachment of Shiga toxigenic Escherichia coli (STEC) to surfaces and the formation of biofilms may enhance persistence in a food processing environment and present a risk of contaminating products. Seven strains of STEC and three non-STEC strains were selected to compare two biofilm quantification methods; epifluorescence microscopy on stainless steel (SS) and a microtitre plate assay. The influence of prior growth in planktonic (nutrient broth) and sessile (nutrient agar) culture on biofilm production, as well as expression of surface structures and the possession of antigen 43 (encoded by agn43) on biofilm formation were also investigated. Biofilms were produced in diluted nutrient broth at 25 degrees C for 24 and 48 h. Curli expression was determined using congo red indicator agar, while the presence of agn43 was determined using polymerase chain reaction. No correlation was found between counts for epifluorescence microscopy on SS and the absorbance values obtained with the microtitre plate method for planktonic and sessile grown cultures. Different abilities of individual STEC strains to attach to SS and microtitre plates were found with some strains attaching better to each surface following growth in either planktonic or sessile culture. All O157 STEC strains had low biofilm counts on SS for planktonic and sessile grown cultures; however, one STEC O157:H- strain (EC516) had significantly greater (p<0.05) biofilm production on microtitre plates compared to the other O157 STEC strains. EC516 and other STEC (O174:H21 and O91:H21) strains expressing curli fimbriae were found to produce significantly greater (p<0.05) biofilms on microtitre plates compared to the non-curli expressing strains. No relationship was found between the production of type-I fimbriae, motility, agn43 and bacterial physicochemical properties (previously determined) and biofilm formation on SS or microtitre plates. Variations between the two biofilm determination methods may suggest that the biofilm production on microtitre plates may not be appropriate to represent other surfaces such as SS and that caution should be taken when selecting a method to quantify biofilm production on a surface.
Long-Term Bacterial Dynamics in a Full-Scale Drinking Water Distribution System
Prest, E. I.; Weissbrodt, D. G.; Hammes, F.; van Loosdrecht, M. C. M.; Vrouwenvelder, J. S.
2016-01-01
Large seasonal variations in microbial drinking water quality can occur in distribution networks, but are often not taken into account when evaluating results from short-term water sampling campaigns. Temporal dynamics in bacterial community characteristics were investigated during a two-year drinking water monitoring campaign in a full-scale distribution system operating without detectable disinfectant residual. A total of 368 water samples were collected on a biweekly basis at the water treatment plant (WTP) effluent and at one fixed location in the drinking water distribution network (NET). The samples were analysed for heterotrophic plate counts (HPC), Aeromonas plate counts, adenosine-tri-phosphate (ATP) concentrations, and flow cytometric (FCM) total and intact cell counts (TCC, ICC), water temperature, pH, conductivity, total organic carbon (TOC) and assimilable organic carbon (AOC). Multivariate analysis of the large dataset was performed to explore correlative trends between microbial and environmental parameters. The WTP effluent displayed considerable seasonal variations in TCC (from 90 × 103 cells mL-1 in winter time up to 455 × 103 cells mL-1 in summer time) and in bacterial ATP concentrations (<1–3.6 ng L-1), which were congruent with water temperature variations. These fluctuations were not detected with HPC and Aeromonas counts. The water in the network was predominantly influenced by the characteristics of the WTP effluent. The increase in ICC between the WTP effluent and the network sampling location was small (34 × 103 cells mL-1 on average) compared to seasonal fluctuations in ICC in the WTP effluent. Interestingly, the extent of bacterial growth in the NET was inversely correlated to AOC concentrations in the WTP effluent (Pearson’s correlation factor r = -0.35), and positively correlated with water temperature (r = 0.49). Collecting a large dataset at high frequency over a two year period enabled the characterization of previously undocumented seasonal dynamics in the distribution network. Moreover, high-resolution FCM data enabled prediction of bacterial cell concentrations at specific water temperatures and time of year. The study highlights the need to systematically assess temporal fluctuations in parallel to spatial dynamics for individual drinking water distribution systems. PMID:27792739
Long-Term Bacterial Dynamics in a Full-Scale Drinking Water Distribution System.
Prest, E I; Weissbrodt, D G; Hammes, F; van Loosdrecht, M C M; Vrouwenvelder, J S
2016-01-01
Large seasonal variations in microbial drinking water quality can occur in distribution networks, but are often not taken into account when evaluating results from short-term water sampling campaigns. Temporal dynamics in bacterial community characteristics were investigated during a two-year drinking water monitoring campaign in a full-scale distribution system operating without detectable disinfectant residual. A total of 368 water samples were collected on a biweekly basis at the water treatment plant (WTP) effluent and at one fixed location in the drinking water distribution network (NET). The samples were analysed for heterotrophic plate counts (HPC), Aeromonas plate counts, adenosine-tri-phosphate (ATP) concentrations, and flow cytometric (FCM) total and intact cell counts (TCC, ICC), water temperature, pH, conductivity, total organic carbon (TOC) and assimilable organic carbon (AOC). Multivariate analysis of the large dataset was performed to explore correlative trends between microbial and environmental parameters. The WTP effluent displayed considerable seasonal variations in TCC (from 90 × 103 cells mL-1 in winter time up to 455 × 103 cells mL-1 in summer time) and in bacterial ATP concentrations (<1-3.6 ng L-1), which were congruent with water temperature variations. These fluctuations were not detected with HPC and Aeromonas counts. The water in the network was predominantly influenced by the characteristics of the WTP effluent. The increase in ICC between the WTP effluent and the network sampling location was small (34 × 103 cells mL-1 on average) compared to seasonal fluctuations in ICC in the WTP effluent. Interestingly, the extent of bacterial growth in the NET was inversely correlated to AOC concentrations in the WTP effluent (Pearson's correlation factor r = -0.35), and positively correlated with water temperature (r = 0.49). Collecting a large dataset at high frequency over a two year period enabled the characterization of previously undocumented seasonal dynamics in the distribution network. Moreover, high-resolution FCM data enabled prediction of bacterial cell concentrations at specific water temperatures and time of year. The study highlights the need to systematically assess temporal fluctuations in parallel to spatial dynamics for individual drinking water distribution systems.
Bacteriological quality of drinking water from dispensers (coolers) and possible control measures.
Baumgartner, Andreas; Grand, Marius
2006-12-01
Three water dispensers (coolers) were bacteriologically monitored over a period of 3 months to evaluate their hygienic status. For this purpose, 174 samples of chilled and unchilled water were analyzed for levels of mesophilic aerobic bacteria and the presence of Escherichia coli and enterococci in 100-ml samples, and the presence of Pseudomonas aeruginosa in 10- and 100-ml samples. Additionally, 12 samples from 20-liter plastic bottles of spring water used to supply the coolers and 36 samples of 12 different brands of noncarbonated bottled mineral water were similarly analyzed. Water from the coolers yielded aerobic plate counts of 3 to 5 log CFU/ml with a geometric mean of 3.86 log CFU/ml, whereas water from the 20-liter bottles had a mean aerobic plate count of 3.3 log CFU/ml. Aerobic plate counts for noncarbonated mineral waters were generally lower (13 samples, < 10 CFU/ml; 6 samples, 10 to 10(2) CFU/ml; 13 samples, 10(2) to 10(3) CFU/ml; 3 samples, 10(3) to 10(4) CFU/ ml; 1 sample, 2 x 10(4) CFU/ml). Although occasional professional cleaning of the coolers did not affect the aerobic plate count, P. aeruginosa was successfully eliminated 2 weeks after cleaning, with only one cooler becoming recolonized. Neither E. coli nor enterococci was found in any of the water samples tested. However, P. aeruginosa was identified in three (25%) of twelve 100-ml samples from 20-liter bottles of spring water; a similar frequency of 24.1% was seen for water samples from coolers. Overall, 35 (21.6%) of 162 water samples (10 ml) from coolers also yielded P. aeruginosa, suggesting potential growth of P. aeruginosa in the dispensers. Pulsed-field gel electrophoresis typing and antibiotic susceptibility testing found 19 P. aeruginosa isolates from the coolers and bottles to be identical, indicating that a single strain originated from the bottled water rather than the surroundings of the coolers. Because P. aeruginosa can cause serious nosocomial infections, its spread should be strictly controlled in institutions caring for vulnerable people such as hospitals and nursing homes. Consequently, in keeping with legal requirement for bottled spring and mineral water in Switzerland, it is also advisable that P. aeruginosa be absent in 100-ml samples of cooler water.
The application of the hazard analysis and control points (HACCP) in an ice cream production plant.
El-Tawila, M M
1998-01-01
The HACCP system is applied in the present study as a preventive food safety approach to control some hazards appearing in one of the ice cream production plants in Egypt. The problem comprised the presence of bacteriological and some chemical contamination in most of the company products. Before applying the HACCP system, the samples examination showed high total mesophilic plat count in 50% of the samples and high coliform count in all samples compared to the level recommended in the Egyptian standards. The highest staphylococcal count (negative for coagulase test) obtained was that of chocolate (1.3 x 10(4) CFU/g) followed by mango ice cream (l.0 x 10(4) CFU/g). Faecal coliform was only positive in mango ice cream. Additionally, the levels of lead, iron and copper have been determined. Copper was higher than the recommended level in all samples and ranged between 0.46 ppm in pistachio ice cream and 2.48 ppm in chocolate ice cream. Most of the CCPs in the ice cream production were mainly due to improper handling and practices throughout the processing steps and also related to the lack of food hygiene knowledge of the workers. The application of HACCP system has successfully reduced the bacteriological hazards in all samples. After applying the corrective actions, the highest total aerobic plate count (8.0 x 10(4)) was that of Swiss chocolate ice cream which corresponds to 50% of the recommended level by the Egyptian standards. Coliform count was less than 10 in all samples except mango ice cream (43 MPN). A significant decrease in staphylococcal count, faecal coliform and trace metal contamination was also recorded in all samples.
Sharma, Rama; Reddy, Vamsi Krishna L; Prashant, GM; Ojha, Vivek; Kumar, Naveen PG
2014-01-01
Context: Several studies have demonstrated the activity of natural plants on the dental biofilm and caries development. But few studies on the antimicrobial activity of coffee-based solutions were found in the literature. Further there was no study available to check the antimicrobial effect of coffee solutions with different percentages of chicory in it. Aims: To evaluate the antimicrobial activity of different combinations of coffee-chicory solutions and their anti-adherence effect on Streptococcus mutans to glass surface. Materials and Methods: Test solutions were prepared. For antimicrobial activity testing, tubes containing test solution and culture medium were inoculated with a suspension of S. mutans followed by plating on Brain Heart Infusion (BHI) agar. S. mutans adherence to glass in presence of the different test solutions was also tested. The number of adhered bacteria (CFU/mL) was determined by plating method. Statistical Analysis: Statistical significance was measured using one way ANOVA followed by Tukey's post hoc test. P value < 0.05 was considered statistically significant. Results: Pure chicory had shown significantly less bacterial count compared to all other groups. Groups IV and V had shown significant reduction in bacterial counts over the period of 4 hrs. Regarding anti-adherence effect, group I-IV had shown significantly less adherence of bacteria to glass surface. Conclusions: Chicory exerted antibacterial effect against S. mutans while coffee reduced significantly the adherence of S. mutans to the glass surface. PMID:25328299
NASA Astrophysics Data System (ADS)
Hertanto, B. S.; Nurmalasari, C. D. A.; Nuhriawangsa, A. M. P.; Cahyadi, M.; Kartikasari, L. R.
2018-01-01
The aim of this study was to determine the physical and microbiological quality of chicken meat produced by the different type of enterprise slaughterhouse in Karanganyar District. The number of 20 poultry slaughterhouses was determined by convenience sampling method. The samples of chicken meat were randomly collected from medium enterprise poultry slaughterhouses (n=12) and small enterprise poultry slaughterhouses (n=8). A survey was carried out among poultry slaughterhouses in Karanganyar District. All the samples were subjected to physical quality consisted of pH test, texture, and color, while microbiological quality consisted of total plate count, microbial detection of Escherichia coli and Salmonella. The data were analyzed using descriptive quantitative analysis. The study showed that chicken meat in 6 small enterprise slaughterhouses and 11 medium enterprise slaughterhouses had normal pH of 5.81 - 6.3. Color and texture of chicken meats had relatively normal in both small and medium enterprise slaughterhouses. The total plate count of chicken meat showed in both small and medium enterprise slaughterhouses was <1x106 CFU/gr. The test of bacterial contamination showed that 3 of small and medium enterprise slaughterhouses were positively contaminated by Escherichia coli of >1x101 CFU/gr, and Salmonella was detected in 1 medium enterprise slaughterhouse. The overall results of the study suggest that the potential risk of chicken meat contamination depends on the processing of chicken meat in poultry slaughterhouses.
Basheer, Jasim; Ravi, Aswani; Mathew, Jyothis; Krishnankutty, Radhakrishnan Edayileveettil
2018-01-25
Endophytic bacteria are considered to have a plethora of plant growth promoting and anti-phytopathogenic traits to live within the plants. Hence, they have immense promises for plant probiotic development. In the current study, plant probiotic endophytic Bacillus sp. CaB5 which has been previously isolated from Capsicum annuum was investigated for its performance in talc-based formulation. For this, CaB5 was made into formulation with sterile talc, calcium carbonate, and carboxymethyl cellulose. The viability analysis of the formulation by standard plate count and fluorescence methods has confirmed the stable microbial count up to 45 days. Plant probiotic performance of the prepared formulation was analyzed on cowpea (Vigna unguiculata) and lady's finger (Abelmoschus esculentus). The results showed the formulation treatment to have enhancement effect on seed germination as well as plant growth in both selected plants. The results highlight the potential of CaB5-based formulation for field application to enhance growth of economically important plants.
Bacteriological and genetic assessment of game meat from Japanese wild boars.
Naya, Yuka; Horiuchi, Motohiro; Ishiguro, Naotaka; Shinagawa, Morikazu
2003-01-15
Bacterial tests were used to assess bacterial contamination of game meat from Japanese wild boars. The bacterial contamination of wild boar meat was less than that of domestic pork, as determined by aerobic plate counts (APC) and coliform counts. None of the meat examined in this study was contaminated by Salmonella or E. coli O-157. To detect adulteration by domestic pig meat or European wild boar meat, 46 samples of game meat sold as Japanese wild boar were examined genetically. A total of 17 samples showed genetic haplotypes of European and Asian domestic pigs in the D-loop of mitochondrial DNA (mtDNA), and 16 samples showed nuclear glucosephosphate isomerase-processed pseudogene (GPIP) genotypes of European domestic pigs. The European GPIP genotypes of these samples were confirmed by PCR-RFLP analysis. These results indicate that some game meat sold as Japanese wild boar is adulterated by cross-breeding between pigs and wild boars or by contamination with meat from domestic pigs or European wild boars.
Hassan, Afrah Fatima; Yadav, Gunjan; Tripathi, Abhay Mani; Mehrotra, Mridul; Saha, Sonali; Garg, Nishita
2016-01-01
Caries excavation is a noninvasive technique of caries removal with maximum preservation of healthy tooth structure. To compare the efficacy of three different caries excavation techniques in reducing the count of cariogenic flora. Sixty healthy primary molars were selected from 26 healthy children with occlusal carious lesions without pulpal involvement and divided into three groups in which caries excavation was done with the help of (1) carbide bur; (2) polymer bur using slow-speed handpiece; and (3) ultrasonic tip with ultrasonic machine. Samples were collected before and after caries excavation for microbiological analysis with the help of sterile sharp spoon excavator. Samples were inoculated on blood agar plate and incubated at 37°C for 48 hours. After bacterial cultivation, the bacterial count of Streptococcus mutans was obtained. All statistical analysis was performed using SPSS 13 statistical software version. Kruskal-Wallis analysis of variance, Wilcoxon matched pairs test, and Z test were performed to reveal the statistical significance. The decrease in bacterial count of S. mutans before and after caries excavation was significant (p < 0.001) in all the three groups. Carbide bur showed most efficient reduction in cariogenic flora, while ultrasonic tip showed almost comparable results, while polymer bur showed least reduction in cariogenic flora after caries excavation. Hassan AF, Yadav G, Tripathi AM, Mehrotra M, Saha S, Garg N. A Comparative Evaluation of the Efficacy of Different Caries Excavation Techniques in reducing the Cariogenic Flora: An in vivo Study. Int J Clin Pediatr Dent 2016;9(3):214-217.
Microbiological Analysis in Three Diverse Natural Geothermal Bathing Pools in Iceland
Thorolfsdottir, Berglind Osk Th.; Marteinsson, Viggo Thor
2013-01-01
Natural thermal bathing pools contain geothermal water that is very popular to bathe in but the water is not sterilized, irradiated or treated in any way. Increasing tourism in Iceland will lead to increasing numbers of bath guests, which can in turn affect the microbial flora in the pools and therefore user safety. Today, there is no legislation that applies to natural geothermal pools in Iceland, as the water is not used for consumption and the pools are not defined as public swimming pools. In this study, we conducted a microbiological analysis on three popular but different natural pools in Iceland, located at Lýsuhóll, Hveravellir and Landmannalaugar. Total bacterial counts were performed by flow cytometry, and with plate count at 22 °C, 37 °C and 50 °C. The presence of viable coliforms, Enterococcus spp. and pseudomonads were investigated by growth experiments on selective media. All samples were screened for noroviruses by real time PCR. The results indicate higher fecal contamination in the geothermal pools where the geothermal water flow was low and bathing guest count was high during the day. The number of cultivated Pseudomonas spp. was high (13,000–40,000 cfu/100 mL) in the natural pools, and several strains were isolated and classified as opportunistic pathogens. Norovirus was not detected in the three pools. DNA was extracted from one-liter samples in each pool and analyzed by partial 16S rRNA gene sequencing. Microbial diversity analysis revealed different microbial communities between the pools and they were primarily composed of alpha-, beta- and gammaproteobacteria. PMID:23493033
Seasonal microbial and environmental parameters at Crocker Reef, Florida Keys, 2014–2015
Kellogg, Christina A.; Yates, Kimberly K.; Lawler, Stephanie N.; Moore, Christopher S.; Smiley, Nathan A.
2015-11-04
Microbial measurements included enumeration of total bacteria, enumeration of virus-like particles, and plate counts of Vibrio spp. colony-forming units (CFU). These measurements were intended to give a sense of any seasonal changes in the total microbial load and to provide an indication of water quality. Additional environmental parameters measured included water temperature, salinity, dissolved oxygen, and pH. Four sites (table 1) were intensively sampled for periods of approximately 48 hours during summer (July 2014) and winter (January–February 2015), during which water samples were collected every 4 hours for analysis, except when prevented by weather conditions.
Alizadeh Behbahani, Behrooz; Tabatabaei Yazdi, Farideh; Shahidi, Fakhri; Mortazavi, Seyed Ali; Mohebbi, Mohebbat
2017-04-01
Principle component analysis (PCA) was employed to examine the effect of the exerted treatments on the beef shelf life as well as discovering the correlations between the studied responses. Considering the variability of the dimensions of the responses, correlation coefficients were applied to form the matrix and extract the eigenvalue. Antimicrobial effect was evaluated on 10 pathogenic microorganisms through the methods of hole-plate diffusion method, disk diffusion method, pour plate method, minimum inhibitory concentration and minimum bactericidal/fungicidal concentration. Antioxidant potential and total phenolic content were examined through the method of 2,2-diphenyl-1-picrylhydrazyl (DPPH) and Folin-Ciocalteu method, respectively. The components were identified through gas chromatography and gas chromatography/mass spectrometry. Barhang seed mucilage (BSM) based edible coating containing 0, 0.5, 1 and 1.5% (w/w) Tarragon (T) essential oil mix were applied on beef slices to control the growth of pathogenic microorganisms. Microbiological (total viable count, psychrotrophic count, Escherichia coli, Staphylococcus aureus and fungi), chemical (thiobarbituric acid, peroxide value and pH) and sensory characteristics (odor, color and overall acceptability) analysis measurements were made during the storage periodically. PCA was employed to examine the effect of the exerted treatments on the beef shelf life as well as discovering the correlations between the studied responses. Considering the variability of the dimensions of the responses, correlation coefficients were applied to form the matrix and extract the eigenvalue. The PCA showed that the properties of the uncoated meat samples on the 9th, 12th, 15th and 18th days of storage are continuously changing independent of the exerted treatments on the other samples. This reveals the effect of the exerted treatments on the samples. Copyright © 2017 Elsevier Ltd. All rights reserved.
Nickerson, Kourtney P; Faherty, Christina S
2018-05-06
Biofilm formation is a dynamic, multistage process that occurs in bacteria under harsh environmental conditions or times of stress. For enteric pathogens, a significant stress response is induced during gastrointestinal transit and upon bile exposure, a normal component of human digestion. To overcome the bactericidal effects of bile, many enteric pathogens form a biofilm hypothesized to permit survival when transiting through the small intestine. Here we present methodologies to define biofilm formation through solid-phase adherence assays as well as extracellular polymeric substance (EPS) matrix detection and visualization. Furthermore, biofilm dispersion assessment is presented to mimic the analysis of events triggering release of bacteria during the infection process. Crystal violet staining is used to detect adherent bacteria in a high-throughput 96-well plate adherence assay. EPS production assessment is determined by two assays, namely microscopy staining of the EPS matrix and semi-quantitative analysis with a fluorescently-conjugated polysaccharide binding lectin. Finally, biofilm dispersion is measured through colony counts and plating. Positive data from multiple assays support the characterization of biofilms and can be utilized to identify bile salt-induced biofilm formation in other bacterial strains.
Rubik, Beverly; Brooks, Audrey J; Schwartz, Gary E
2006-01-01
To measure effects of Reiki treatments on growth of heat-shocked bacteria, and to determine the influence of healing context and practitioner well-being. Overnight cultures of Escherichia coli K12 in fresh medium were used. Culture samples were paired with controls to minimize any ordering effects. Samples were heat-shocked prior to Reiki treatment, which was performed by Reiki practitioners for up to 15 minutes, with untreated controls. Plate-count assay using an automated colony counter determined the number of viable bacteria. Fourteen Reiki practitioners each completed 3 runs (n = 42 runs) without healing context, and another 2 runs (n = 28 runs) in which they first treated a pain patient for 30 minutes (healing context). Well-being questionnaires were administered to practitioners pre-post all sessions. No overall difference was found between the Reiki and control plates in the nonhealing context. In the healing context, the Reiki treated cultures overall exhibited significantly more bacteria than controls (p < 0.05). Practitioner social (p < 0.013) and emotional well-being (p < 0.021) correlated with Reiki treatment outcome on bacterial cultures in the nonhealing context. Practitioner social (p < 0.031), physical (p < 0.030), and emotional (p < 0.026) well-being correlated with Reiki treatment outcome on the bacterial cultures in the healing context. For practitioners starting with diminished well-being, control counts were likely to be higher than Reiki-treated bacterial counts. For practitioners starting with a higher level of well-being, Reiki counts were likely to be higher than control counts. Reiki improved growth of heat-shocked bacterial cultures in a healing context. The initial level of well-being of the Reiki practitioners correlates with the outcome of Reiki on bacterial culture growth and is key to the results obtained.
Nonuniform spatial patterns of respiratory activity within biofilms during disinfection.
Huang, C T; Yu, F P; McFeters, G A; Stewart, P S
1995-01-01
Fluorescent stains in conjunction with cryoembedding and image analysis were applied to demonstrate spatial gradients in respiratory activity within bacterial biofilms during disinfection with monochloramine. Biofilms of Klebsiella pneumoniae and Pseudomonas aeruginosa grown together on stainless steel surfaces in continuous-flow annular reactors were treated with 2 mg of monochloramine per liter (influent concentration) for 2 h. Relatively little biofilm removal occurred as evidenced by total cell direct counts. Plate counts (of both species summed) indicated an average 1.3-log decrease after exposure to 2 mg of monochloramine per liter. The fluorogenic redox indicator 5-cyano-2,3-ditolyl tetrazolium chloride (CTC) and the DNA stain 4',6-diamidino-2-phenylindole (DAPI) were used to differentiate respiring and nonrespiring cells in biofilms. Epifluorescence micrographs of frozen biofilm cross sections clearly revealed gradients of respiratory activity within biofilms in response to monochloramine treatment. These gradients in specific respiratory activity were quantified by calculating the ratio of CTC and DAPI intensities measured by image analysis. Cells near the biofilm-bulk fluid interface lost respiratory activity first. After 2 h of biocide treatment, greater respiratory activity persisted deep in the biofilm than near the biofilm-bulk fluid interface. PMID:7793945
Beyond the standard plate count: genomic views into microbial food ecology
USDA-ARS?s Scientific Manuscript database
Food spoilage is a complex process that involves multiple species with specific niches and metabolic processes; bacterial culturing techniques are the traditional methods for identifying the microbes responsible. These culture-dependent methods may be considered selective, targeting the isolation of...
Code of Federal Regulations, 2011 CFR
2011-07-01
... serves water to the public. Water in the distribution system with a heterotrophic bacteria concentration... heterotrophic bacteria plate count (HPC) is measured; c=number of instances where the residual disinfectant... system with a heterotrophic bacteria concentration less than or equal to 500/ml, measured as...
Code of Federal Regulations, 2013 CFR
2013-07-01
... serves water to the public. Water in the distribution system with a heterotrophic bacteria concentration... heterotrophic bacteria plate count (HPC) is measured; c=number of instances where the residual disinfectant... system with a heterotrophic bacteria concentration less than or equal to 500/ml, measured as...
High Speed Large Format Photon Counting Microchannel Plate Imaging Sensors
NASA Astrophysics Data System (ADS)
Siegmund, O.; Ertley, C.; Vallerga, J.; Craven, C.; Popecki, M.; O'Mahony, A.; Minot, M.
The development of a new class of microchannel plate technology, using atomic layer deposition (ALD) techniques applied to a borosilicate microcapillary array is enabling the implementation of larger, more stable detectors for Astronomy and remote sensing. Sealed tubes with MCPs with SuperGenII, bialkali, GaAs and GaN photocathodes have been developed to cover a wide range of optical/UV sensing applications. Formats of 18mm and 25mm circular, and 50mm (Planacon) and 20cm square have been constructed for uses from night time remote reconnaissance and biological single-molecule fluorescence lifetime imaging microscopy, to large area focal plane imagers for Astronomy, neutron detection and ring imaging Cherenkov detection. The large focal plane areas were previously unattainable, but the new developments in construction of ALD microchannel plates allow implementation of formats of 20cm or more. Continuing developments in ALD microchannel plates offer improved overall sealed tube lifetime and gain stability, and furthermore show reduced levels of radiation induced background. High time resolution astronomical and remote sensing applications can be addressed with microchannel plate based imaging, photon time tagging detector sealed tube schemes. Photon counting imaging readouts for these devices vary from cross strip (XS), cross delay line (XDL), to stripline anodes, and pad arrays depending on the intended application. The XS and XDL readouts have been implemented in formats from 22mm, and 50mm to 20cm. Both use MCP charge signals detected on two orthogonal layers of conductive fingers to encode event X-Y positions. XDL readout uses signal propagation delay to encode positions while XS readout uses charge cloud centroiding. Spatial resolution readout of XS detectors can be better than 20 microns FWHM, with good image linearity while using low gain (<10^6), allowing high local counting rates and longer overall tube lifetime. XS tubes with electronics can encode event rates of >5 MHz and event timing accuracy of ~100ps. We will discuss how we are applying these detector system developments for devices in formats of 18mm and 25mm circular, and 50mm and 20cm square. The performance characteristics will be demonstrated along with lifetest data taken over the last year. Implications for ground based instruments to study transient and variable astronomical objects, as well as implementation in satellite instruments for earth atmospheric, planetary and solar observations will be discussed.
Cui, Xiaonan; Ren, Lihui; Shan, Yufei; Wang, Xixian; Yang, Zhenlong; Li, Chunyu; Xu, Jian; Ma, Bo
2018-05-18
Standard plate count (SPC) has been recognized as the golden standard for the quantification of viable bacteria. However, SPC usually takes one to several days to grow individual cells into a visible colony, which greatly hampers its application in rapid bacteria enumeration. Here we present a microdroplet turbidity imaging based digital standard plate count (dSPC) method to overcome this hurdle. Instead of cultivating on agar plates, bacteria are encapsulated in monodisperse microdroplets for single-cell cultivation. Proliferation of the encapsulated bacterial cell produced a detectable change in microdroplet turbidity, which allowed, after just a few bacterial doubling cycles (i.e., a few hours), enumeration of viable bacteria by visible-light imaging. Furthermore, a dSPC platform integrating a power-free droplet generator with smartphone-based turbidity imaging was established. As proof-of-concept demonstrations, a series of Gram-negative bacteria (Escherichia coli) and Gram-positive bacteria (Bacillus subtilis) samples were quantified via the smartphone dSPC accurately within 6 hours, representing a detection sensitivity of 100 CFU ml-1 and at least 3 times faster. In addition, Enterobacter sakazakii (E. sakazakii) in infant milk powder as a real sample was enumerated within 6 hours, in contrast to the 24 hours needed in traditional SPC. Results with high accuracy and reproducibility were achieved, with no difference in counts found between dSPC and SPC. By enabling label-free, rapid, portable and low-cost enumeration and cultivation of viable bacteria onsite, smartphone dSPC forms the basis for a temporally and geographically trackable network for surveying live microbes globally where every citizen with a cellphone can contribute anytime and anywhere.
Liming Poultry Manures to Kill Pathogens and Decrease Soluble Phosphorus
DOE Office of Scientific and Technical Information (OSTI.GOV)
Maguire,R.; Hesterberg, D.; Gernat, A.
2006-01-01
Received for publication September 9, 2005. Stabilizing phosphorus (P) in poultry waste to reduce P losses from manured soils is important to protect surface waters, while pathogens in manures are an emerging issue. This study was conducted to evaluate CaO and Ca(OH){sub 2} for killing manure bacterial populations (pathogens) and stabilizing P in poultry wastes and to investigate the influence on soils following amendment with the treated wastes. Layer manure and broiler litter varying in moisture content were treated with CaO and Ca(OH){sub 2} at rates of 2.5, 5, 10, and 15% by weight. All treated wastes were analyzed formore » microbial plate counts, pH, and water-soluble phosphorus (WSP), while a few selected layer manures were analyzed by phosphorus X-ray absorption near edge structure (XANES). A loamy sand and a silt loam were amended with broiler litter and layer manure treated with CaO at rates of 0, 2.5, 5, 10, and 15% and soil WSP and pH were measured at times 1, 8, and 29 d. Liming reduced bacterial populations, with greater rates of lime leading to greater reductions; for example 10% CaO applied to 20% solids broiler litter reduced the plate counts from 793 000 to 6500 mL{sup -1}. Liming also reduced the WSP in the manures by over 90% in all cases where at least 10% CaO was added. Liming the manures also reduced WSP in soils immediately following application and raised soil pH. The liming process used successfully reduced plate counts and concerns about P losses in runoff following land application of these limed products due to decreased WSP.« less
Microbial quality and associated health risks of raw milk marketed in the Tanga region of Tanzania.
Swai, E S; Schoonman, L
2011-06-01
To evaluate microbial quality and associated health risks of raw milk marketed in the Tanga region of Tanzania. A microbial quality assessment of marketed raw milk was undertaken by evaluating 59 samples of milk from selling points (collecting centres =15), bicycle boys (12) and kiosks/restaurants (32) in Tanga city during April-May 2005. Quality and milk-borne hazards were assessed using a combination of tests in order to quantify the occurrence of Brucellosis (milk ring test), Escherichia coli (E. coli) O157:H7 (culture), the coliform bacteria as well as standard plate count (SPC). Specific gravity (SG) determination was used as an indicator of adulteration. The mean coliform plate count (c.f.u/mL) of milk handled by bicycle boys (4.2×10(6)) was significantly higher than that handled by collecting centres (3.0×10(6)) and kiosk/ restaurants (1.4×10(6)), respectively (P < 0.05). Of the 59 milk samples collected, 33 (56%) were Brucella milk ring test (MRT)-positive and 78% and 17% of the samples graded satisfactorily based on SG and coliform plate counts as prescribed by East African Community standards for raw milk. There was no verocytotoxigenic E. coli (VTEC) O157: H7 in any of the milk samples collected and analysed during the present study. It can be concluded that raw market milk in the study area is of poor bacteriological quality and hazardous for human consumption. This highlights the need to implement good hygiene practices and effective monitoring from production through the delivery chain to the consumer. Further studies are needed for detection of toxins that are produced by E. coli, other pathogenic spore forming bacteria (Bacillus spp. and Clostridium spp.) and other harmful microorganisms.
Liming poultry manures to decrease soluble phosphorus and suppress the bacteria population.
Maguire, R O; Hesterberg, D; Gernat, A; Anderson, K; Wineland, M; Grimes, J
2006-01-01
Stabilizing phosphorus (P) in poultry waste to reduce P losses from manured soils is important to protect surface waters, while pathogens in manures are an emerging issue. This study was conducted to evaluate CaO and Ca(OH)2 for killing manure bacterial populations (pathogens) and stabilizing P in poultry wastes and to investigate the influence on soils following amendment with the treated wastes. Layer manure and broiler litter varying in moisture content were treated with CaO and Ca(OH)2 at rates of 2.5, 5, 10, and 15% by weight. All treated wastes were analyzed for microbial plate counts, pH, and water-soluble phosphorus (WSP), while a few selected layer manures were analyzed by phosphorus X-ray absorption near edge structure (XANES). A loamy sand and a silt loam were amended with broiler litter and layer manure treated with CaO at rates of 0, 2.5, 5, 10, and 15% and soil WSP and pH were measured at times 1, 8, and 29 d. Liming reduced bacterial populations, with greater rates of lime leading to greater reductions; for example 10% CaO applied to 20% solids broiler litter reduced the plate counts from 793,000 to 6500 mL-1. Liming also reduced the WSP in the manures by over 90% in all cases where at least 10% CaO was added. Liming the manures also reduced WSP in soils immediately following application and raised soil pH. The liming process used successfully reduced plate counts and concerns about P losses in runoff following land application of these limed products due to decreased WSP.
Effects of 1-MeV gamma radiation on a multi-anode microchannel array detector tube
NASA Technical Reports Server (NTRS)
Timothy, J. G.; Bybee, R. L.
1979-01-01
A multianode microchannel array (MAMA) detector tube without a photocathode was exposed to a total dose of 1,000,000 rads of 1-MeV gamma radiation from a Co-60 source. The high-voltage characteristic of the microchannel array plate, average dark count, gain, and resolution of pulse height distribution characteristics showed no degradation after this total dose. In fact, the degassing of the microchannels induced by the high radiation flux had the effect of cleaning up the array plate and improving its characteristics.
Impedance technology reduces the enumeration time of Brettanomyces yeast during beer fermentation.
van Wyk, Sanelle; Silva, Filipa V M
2016-12-01
Brettanomyces yeasts are increasingly being used to produce lambic style beers and craft beers with unique flavors. Currently, the industry monitors Brettanomyces bruxellensis using time consuming plate counting. B. bruxellensis is a fastidious slow growing organism, requiring five days of incubation at 30°C for visible growth on agar plates. Thus, a need exists to develop a quicker, feasible method to enumerate this yeast. The aim of this study was therefore to determine the feasibility of using the 'direct' and 'indirect' impedance methods for the enumeration of B. bruxellensis in beer and to monitor the growth of the yeast during fermentation. The impedance methods were able to decrease the incubation time of beer samples containing Brettanomyces from 120 h down to 2 and 84 h for samples containing 10 7 and 10 3 cfu/mL, respectively. The 'indirect' method was more successful than the 'direct' method, presenting a smaller error and wider detection range. Overall, the 'indirect' impedance method is a viable alternative to plate counting for the enumeration of yeasts in the brewing industry because it decreases preparation and incubation times, thereby increasing throughput and decreasing the chance of contamination. Copyright © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Chan, Leo Li-Ying; Smith, Tim; Kumph, Kendra A; Kuksin, Dmitry; Kessel, Sarah; Déry, Olivier; Cribbes, Scott; Lai, Ning; Qiu, Jean
2016-10-01
To ensure cell-based assays are performed properly, both cell concentration and viability have to be determined so that the data can be normalized to generate meaningful and comparable results. Cell-based assays performed in immuno-oncology, toxicology, or bioprocessing research often require measuring of multiple samples and conditions, thus the current automated cell counter that uses single disposable counting slides is not practical for high-throughput screening assays. In the recent years, a plate-based image cytometry system has been developed for high-throughput biomolecular screening assays. In this work, we demonstrate a high-throughput AO/PI-based cell concentration and viability method using the Celigo image cytometer. First, we validate the method by comparing directly to Cellometer automated cell counter. Next, cell concentration dynamic range, viability dynamic range, and consistency are determined. The high-throughput AO/PI method described here allows for 96-well to 384-well plate samples to be analyzed in less than 7 min, which greatly reduces the time required for the single sample-based automated cell counter. In addition, this method can improve the efficiency for high-throughput screening assays, where multiple cell counts and viability measurements are needed prior to performing assays such as flow cytometry, ELISA, or simply plating cells for cell culture.
Thomas, P; Sekhar, A C; Mujawar, M M
2012-08-01
To elucidate the cause of high variations and inconsistencies in bacterial CFU observed within and between different experiments while assessing viable bacterial counts through spread plating (SP). Following the inconsistent results, CFU estimations were undertaken through conventional SP using the spreader, or a modified approach that did not use spreader employing four organisms. The latter approach involving spotting-and-tilt-spreading of inoculum on agar surface [spotting spreading (SS)] yielded higher CFU by 11-120% over the weighted average depending on the organism and diluent. The adverse effect owing to the spreader was the most obvious in Escherichia coli followed by Staphylococcus epidermidis, Enterobacter cloacae and Bacillus pumilus. Plate attributes that determined the surface moisture levels of agar medium and the spreading practice adopted by the personnel formed two other major influencing factors. Plating for shorter periods (<60 s) using fresh 15/20 ml plates caused loss of 3-12% CFU owing to inoculum adhesion to spreader irrespective of glass or polypropylene make. On the other hand, prolonging the plating brought down the CFU significantly. Spreader movement on agar surface subsequent to the exhaustion of free moisture, which was marked by the experiencing of some friction to smooth spreader movement, was detrimental to vegetative cells, while Bacillus spores were less affected. The study brings out that the way SP is carried out exerts significant effects on CFU influenced by plate conditions. Prolonged use of spreader on dry agar surface could be highly detrimental to bacterial cells. A mild use of spreader accounting for spreader-adhering inoculum or the practice of SS not involving the spreader is recommended. This study unravels the effects owing to the spreader on bacterial cells and the CFU and recommends an alternate approach of SS to minimize CFU inconsistencies and to maximize the viable bacterial counts. © 2012 The Authors Journal of Applied Microbiology © 2012 The Society for Applied Microbiology.
Development of a single-photon-counting camera with use of a triple-stacked micro-channel plate.
Yasuda, Naruomi; Suzuki, Hitoshi; Katafuchi, Tetsuro
2016-01-01
At the quantum-mechanical level, all substances (not merely electromagnetic waves such as light and X-rays) exhibit wave–particle duality. Whereas students of radiation science can easily understand the wave nature of electromagnetic waves, the particle (photon) nature may elude them. Therefore, to assist students in understanding the wave–particle duality of electromagnetic waves, we have developed a photon-counting camera that captures single photons in two-dimensional images. As an image intensifier, this camera has a triple-stacked micro-channel plate (MCP) with an amplification factor of 10(6). The ultra-low light of a single photon entering the camera is first converted to an electron through the photoelectric effect on the photocathode. The electron is intensified by the triple-stacked MCP and then converted to a visible light distribution, which is measured by a high-sensitivity complementary metal oxide semiconductor image sensor. Because it detects individual photons, the photon-counting camera is expected to provide students with a complete understanding of the particle nature of electromagnetic waves. Moreover, it measures ultra-weak light that cannot be detected by ordinary low-sensitivity cameras. Therefore, it is suitable for experimental research on scintillator luminescence, biophoton detection, and similar topics.
Kauppinen, Ari; Ikonen, Jenni; Pursiainen, Anna; Pitkänen, Tarja; Miettinen, Ilkka T
2012-09-01
A contaminated drinking water distribution network can be responsible for major outbreaks of infections. In this study, two chemical decontaminants, peracetic acid (PAA) and chlorine, were used to test how a laboratory-scale pipeline system can be cleaned after simultaneous contamination with human adenovirus 40 (AdV40) and Escherichia coli. In addition, the effect of the decontaminants on biofilms was followed as heterotrophic plate counts (HPC) and total cell counts (TCC). Real-time quantitative polymerase chain reaction (qPCR) was used to determine AdV40 and plate counting was used to enumerate E. coli. PAA and chlorine proved to be effective decontaminants since they decreased the levels of AdV40 and E. coli to below method detection limits in both water and biofilms. However, without decontamination, AdV40 remained present in the pipelines for up to 4 days. In contrast, the concentration of cultivable E. coli decreased rapidly in the control pipelines, implying that E. coli may be an inadequate indicator for the presence of viral pathogens. Biofilms responded to the decontaminants by decreased HPCs while TCC remained stable. This indicates that the mechanism of pipeline decontamination by chlorine and PAA is inactivation rather than physical removal of microbes.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Menlove, Howard Olsen; Henzlova, Daniela
This informal report presents the measurement data and information to document the performance of the advanced Precision Data Technology, Inc. (PDT) sealed cell boron-10 plate neutron detector that makes use of the advanced coating materials and procedures. In 2015, PDT changed the boron coating materials and application procedures to significantly increase the efficiency of their basic corrugated plate detector performance. A prototype sealed cell unit was supplied to LANL for testing and comparison with prior detector cells. Also, LANL had reference detector slabs from the original neutron collar (UNCL) and the new Antech UNCL with the removable 3He tubes. Themore » comparison data is presented in this report.« less
Wohlsen, T; Bates, J; Vesey, G; Robinson, W A; Katouli, M
2006-04-01
To use BioBall cultures as a precise reference standard to evaluate methods for enumeration of Escherichia coli and other coliform bacteria in water samples. Eight methods were evaluated including membrane filtration, standard plate count (pour and spread plate methods), defined substrate technology methods (Colilert and Colisure), the most probable number method and the Petrifilm disposable plate method. Escherichia coli and Enterobacter aerogenes BioBall cultures containing 30 organisms each were used. All tests were performed using 10 replicates. The mean recovery of both bacteria varied with the different methods employed. The best and most consistent results were obtained with Petrifilm and the pour plate method. Other methods either yielded a low recovery or showed significantly high variability between replicates. The BioBall is a very suitable quality control tool for evaluating the efficiency of methods for bacterial enumeration in water samples.
Microbiological quality of frozen cauliflower, corn, and peas obtained at retail markets.
Barnard, R J; Duran, A P; Swartzentruber, A; Schwab, A H; Wentz, B A; Read, R B
1982-01-01
The microbiological quality of blanched frozen cauliflower, cut corn, and peas at the retail level was determined. At 35 degrees C, mean aerobic plate count (APC) values for cauliflower, corn, and peas, respectively, were 30,000, 6,100, and 4,700 per g; at 30 degrees C, the mean APC values were 45,000, 8,500, and 6,800 per g, respectively. Geometric means for coliform, Escherichia coli, and Staphylococcus aureus counts for all three vegetables were less than 10 per g. PMID:6751226
Microbiological survey of five poultry processing plants in the UK.
Mead, G C; Hudson, W R; Hinton, M H
1993-07-01
1. Neck skin samples were taken from chickens and turkeys at all the main stages of processing to monitor changes in total viable count (TVC) and counts of coliforms and pseudomonads. 2. Processing reduced TVC by up to 100-fold. Geometric mean counts after packaging were log10 4.4 to 5.3 CFU/g whilst corresponding counts of coliforms were 2.7 to 3.8 CFU/g. 3. Increases in mean TVC or coliforms as a result of either defeathering or evisceration did not exceed 0.6 log. 4. Pseudomonads represented only a minor fraction of the initial microflora of the bird and were often reduced by scalding to a figure which could not be detected by direct plating of samples; however, subsequent contamination resulted in means between log10 2.9 and 4.0 CFU/g for packaged carcases. 5. Although Staphylococcus aureus was readily isolated from defeathering equipment, mean counts from defeathered carcases were always below log10 3.0 CFU/g.
Comparison of methods for isolation and enumeration of thermophilic actinomycetes from dust.
Treuhaft, M W; Arden Jones, M P
1982-01-01
Thermophilic actinomycetes are the primary sensitizing agents in farmer's lung disease. We compared dilution pour-plate and spread-plate methods for their usefulness in enumerating thermophilic actinomycetes in moldy silage dust and evaluated the ability of a nonquantitative gravity settling technique to recover thermophilic actinomycetes from moldy silage. Spread plates and pour plates yielded similar estimates of total thermophiles. Higher counts were observed on spread plates (P less than 0.05) for Thermoactinomyces candidus, Micropolyspora faeni, and Saccharomonospora viridis. M. faeni and S. viridis were less efficient than T. candidus in breaking through the agar of pour plates to form colonies which could be identified. Coefficients of variability were less than 10% for the two methods. The relative proportion of organisms recovered by the settling method correlated well with that recovered on spread plates for M. faeni (r = 0.79), S. viridis (r = 0.88), and Thermomonospora spp. (r = 0.79), but not well for T. candidus (r = 0.28). When sophisticated air-sampling equipment is not available, dilution spread plates of dust washings provide a reproducible method for enumerating a broad range of thermophilic actinomycetes of interest. The gravity settling method is a simple, rapid alternative when isolation is all that is required. PMID:6761363
Microbial quality of catfish nuggets
USDA-ARS?s Scientific Manuscript database
The microbiological quality of catfish nuggets is not known. Nuggets, purchased from local retailers in the northeast United States (NJ, NY, PA, and DE), were tested for aerobic plate count (APC) at 22 and 37 deg C, Enterobacteriacea, and Escherichia coli/coliform using Petrifilms**™. The BAX**™ ...
Rossitto, P V; Cullor, J S; Crook, J; Parko, J; Sechi, P; Cenci-Goga, B T
2012-12-01
The dairy industry under current pasteurization conditions (15 s at 72°C) and sanitary standards achieves a safe product with excellent quality. In an ever-competitive market there is still a need to improve product quality and extend shelf life of dairy products to increase competitiveness and open up new markets. In an attempt to test the effect of UV irradiation on microbiota of fluid milk, a continuous flow UV system at 254 nm was used to treat 3.5 and 2% fat milk at two UV doses (880 and 1,760 J liter(-1)). Milk was obtained from three processors, and two lots from each processor were assessed. To assess the impact on the most descriptive native microbiota in pasteurized milk after UV illumination, the product was held at two storage temperatures (4 and 7°C) and tested weekly for 5 weeks for aerobic plate counts (psychrotrophic and mesophilic bacteria), laboratory pasteurization counts, aerobic sporeformers, coliform organisms, and titratable acidity. Microbial counts for all tested microorganisms were lower in UV-treated milk when compared with control throughout storage at 4 and 7°C in both 3.5 and 2% fat milk. Sensory analysis indicated that there is a sensory defect associated with UV treatment at the wavelength used.
Prevalence of pathogenic bacteria in street vended ready-to-eat meats in Windhoek, Namibia.
Shiningeni, Daphney; Chimwamurombe, Percy; Shilangale, Renatus; Misihairabgwi, Jane
2018-05-31
To determine the prevalence of pathogenic bacteria in street vended ready-to-eat meats in Windhoek, Namibia, a total of 96 street vended ready to eat meat samples were evaluated. Prevalences of 42%, 52%, 15%, 6% and 83% were observed for Escherichia coli, Staphylococcus aureus, Listeria monocytogenes, Shigella and Enterobacteriaceae respectively, while the highest aerobic plate counts were 7.74 Log 10 cfu/g, 5.67 Log 10 cfu/g, 5.12 Log 10 cfu/g , 4.56 Log 10 cfu/g, 3.3 Log 10 cfu/g, 5.75 Log 10 cfu/g respectively. Unsatisfactory microbial levels were 32% for aerobic plate count, 26% for Enterobacteriaceae, 35% for Escherichia coli, 11% for Listeria monocytogenes, 7% for Staphylococcus aureus and 6% for Shigella. Salmonella was detected in 11% and 40% of samples from two suburbs. The unsatisfactory microbiological quality of some ready-to-eat meats necessitates the provision of training on food safety and hygiene to street vendors for consumer protection. Copyright © 2018 Elsevier Ltd. All rights reserved.
Dahl, C A; Matthews, M E; Marth, E H
1980-06-01
The purpose was to evaluate microbiological quality and end temperature (ET) of portioned food after heating in a microwave oven as used in a hospital cook/chill foodservice system. Beef loaf (15 kg), potatoes (6 kg), and green beans (5 kg) were prepared in a laboratory. After initial cooking to 60 degrees C, and storage (7 degrees C for 24 h), beef loaf (100 g) was microwave heated: 20, 50, 80 or 110 s. Potatoes were reconstituted, stored (7 degrees C for 24 h), portioned (100 g/portion), and microwave-heated: 25, 45, 65 or 84 s. Beans were thawed (7 degrees C for 24 h), portioned (100 g/portion), and microwave-heated: 20, 50, 80 or 110 s. Aerobic plate counts (APC) for foods were obtained throughout product flow. Wide ranges of Et and of APC in foods indicates that research is needed, for greater control of microwave-heating through advanced microwave engineering and food technology, to produce food with constant microbiological quality.
NASA Technical Reports Server (NTRS)
Foster, T. L.
1974-01-01
The effect of storage of dry heat treated Teflon ribbons under nitrogen gas followed by high vacuum on the recovery of hardy organisms from the ribbons was studied. A similar experiment was performed on spore crops of hardy organisms recovered previously from Cape Canaveral. Hardy organisms have been inoculated onto slides and subjected to an artificial Martian environment in an attempt to demonstrate their growth in this environment. Additional experiments using the artificial Martian environment include response of soil samples from the VAB with both constant temperature and freeze-thaw cycles. These experiments were performed with dried soil and soil containing added water. Other investigations included the effect of heatshock on soil samples, psychrophilic counts of new soil samples from the manufacture area of the Viking spacecraft, effect of pour plate versus spread plate on psychrophilic counts, and preparation of spore crops of hardy organisms from Cape Canaveral.
Gopal, Judy; Lee, Chia-Hsun; Wu, Hui-Fen
2012-06-06
This study demonstrates the first use of matrix assisted laser desorption/ionization mass spectrometry (MALDI-MS) to trace the Invivo infection kinetics of the well known deadly pathogen Staphylococcus aureus in Swiss albino mice. The growth curve of the bacteria from the point of injection (200μL of bacterial suspension (10(8)cfu/mL)) into the mouse blood till mortality (death) was periodically analyzed using the plate counting method and MALDI-MS. Bacterial counts of 10(3)cfu/mL were observed in the log phase of the growth curve in the blood and 10(2)cfu/mL were observed in the urine samples. Death occurred in the log phase of the growth curve, where the bacterial counts showed steady increase. In other cases, the bacteria counts started decreasing after 48h and by 96h the bacteria got totally eliminated from the mouse and these mice survived. Direct MALDI-MS was not feasible for tracking the bacteria in the infected blood. However, ionic liquid 1-Butyl-3-methylimidazolium tetrafluoroborate was successful in enabling bacterial detection amidst the strong blood peaks. But, in the case of the urine analysis, it was observed that direct MALDI-MS was adequate to enable detection. The results obtained prove the efficacy of MALDI-MS for analyzing pathogenic bacteria in clinical samples. This article is part of a Special Issue entitled: Proteomics: The clinical link. Copyright © 2011 Elsevier B.V. All rights reserved.
Winter, F H; York, G K; el-Nakhal, H
1971-07-01
A rapid method for estimating the extent of microbial contamination on food and on food processing equipment is described. Microbial cells are rinsed from food or swab samples with sterile diluent and concentrated on the surface of membrane filters. The filters are incubated on a suitable bacteriological medium for 4 hr at 30 C, heated at 105 C for 5 min, and stained. The membranes are then dried at 60 C for 15 min, rendered transparent with immersion oil, and examined microscopically. Data obtained by the rapid method were compared with counts of the same samples determined by the standard plate count method. Over 60 comparisons resulted in a correlation coefficient of 0.906. Because the rapid technique can provide reliable microbiological count information in extremely short times, it can be a most useful tool in the routine evaluation of microbial contamination of food processing facilities and for some foods.
PATHOGENICITY OF DRINKING WATER ISOLATES OF HETEROTROPHIC BACTERIA WITH PUTATIVE VIRULENCE FACTORS
Although the heterotrophic plate count (HPC) bacteria normally found in potable water are not a threat to the healthy population, some of them may be opportunistic pathogens that could cause adverse health effects in individuals with impaired immune systems. Earlier studies of t...
NASA Technical Reports Server (NTRS)
Kimble, Randy A.; Pain, Bedabrata; Norton, Timothy J.; Haas, J. Patrick; Oegerle, William R. (Technical Monitor)
2002-01-01
Silicon array readouts for microchannel plate intensifiers offer several attractive features. In this class of detector, the electron cloud output of the MCP intensifier is converted to visible light by a phosphor; that light is then fiber-optically coupled to the silicon array. In photon-counting mode, the resulting light splashes on the silicon array are recognized and centroided to fractional pixel accuracy by off-chip electronics. This process can result in very high (MCP-limited) spatial resolution while operating at a modest MCP gain (desirable for dynamic range and long term stability). The principal limitation of intensified CCD systems of this type is their severely limited local dynamic range, as accurate photon counting is achieved only if there are not overlapping event splashes within the frame time of the device. This problem can be ameliorated somewhat by processing events only in pre-selected windows of interest of by using an addressable charge injection device (CID) for the readout array. We are currently pursuing the development of an intriguing alternative readout concept based on using an event-driven CMOS Active Pixel Sensor. APS technology permits the incorporation of discriminator circuitry within each pixel. When coupled with suitable CMOS logic outside the array area, the discriminator circuitry can be used to trigger the readout of small sub-array windows only when and where an event splash has been detected, completely eliminating the local dynamic range problem, while achieving a high global count rate capability and maintaining high spatial resolution. We elaborate on this concept and present our progress toward implementing an event-driven APS readout.
Use of Dehydrated Agar to Estimate Microbial Water Quality for Horticulture Irrigation.
Meador, Dustin P; Fisher, Paul R; Guy, Charles L; Harmon, Philip F; Peres, Natalia A; Teplitski, Max
2016-07-01
Petrifilms are dehydrated agar culture plates that have been used to quantify colony forming units (CFU) mL of either aerobic bacteria (Petrifilm-AC) or fungus (Petrifilm-YM), depending on substrate composition. Microbes in irrigation systems can indicate biofilm risk and potential clogging of irrigation emitters. The research objective was to compare counts on Petrifilms versus traditional, hydrated-agar plates using samples collected from recirculated irrigation waters and cultures of isolated known species. The estimated count (in CFU mL) from a recirculated irrigation sample after 7 d of incubation on Petrifilm-YM was only 5.5% of the count quantified using sabouraud dextrose agar (SDA) with chloramphenicol after 14 d. In a separate experiment with a known species, Petrifilm-YM did not successfully culture zoospores of . Isolates of viable zoospores were cultured successfully on potato-dextrose agar (PDA), with comparable counts with a vegetable juice medium supplemented with the antibiotics pimaricin, ampicillin, rifamycin, pentochloronitrobenzene and hymexazol (PARP-H). The quantification of pv. Begoniaceae on Petrifilm-AC was not significantly different ( < 0.05) than on PDA, but was lower than on Reasoner and Goldrich agar (R2A) or with a hemocytometer. The current formulation of Petrifilm-YM is unlikely to be a useful monitoring method for plant pathogens in irrigation water because of the inability to successfully culture oomycetes. However, Petrifilm-AC was an effective method to quantify bacteria and can provide an easy-to-use on-farm tool to monitor biofilm risk and microbial density. Copyright © by the American Society of Agronomy, Crop Science Society of America, and Soil Science Society of America, Inc.
Kim, S A; Jeon, S H; Kim, N H; Kim, H W; Lee, N Y; Cho, T J; Jung, Y M; Lee, S H; Hwang, I G; Rhee, M S
2015-12-01
This study investigated changes in the microbial composition of microbrewed beer during the manufacturing processes and identified potential microbial hazards, effective critical quality control points, and potential contamination routes. Comprehensive quantitative (aerobic plate count, lactic acid bacteria, fungi, acetic acid bacteria, coliforms, and Bacillus cereus) and qualitative (Escherichia coli and eight foodborne pathogens) microbiological analyses were performed using samples of raw materials (malt and manufacturing water), semiprocessed products (saccharified wort, boiled wort, and samples taken during the fermentation and maturation process), and the final product obtained from three plants. The initial aerobic plate count and lactic acid bacteria counts in malt were 5.2 and 4.3 log CFU/g, respectively. These counts were reduced to undetectable levels by boiling but were present at 2.9 and 0.9 log CFU/ml in the final product. Fungi were initially present at 3.6 log CFU/g, although again, the microbes were eliminated by boiling; however, the level in the final product was 4.6 log CFU/ml. No E. coli or foodborne pathogens (except B. cereus) were detected. B. cereus was detected at all stages, although it was not present in the water or boiled wort (total detection rate ¼ 16.4%). Results suggest that boiling of the wort is an effective microbial control measure, but careful management of raw materials and implementation of effective control measures after boiling are needed to prevent contamination of the product after the boiling step. The results of this study may constitute useful and comprehensive information regarding the microbiological quality of microbrewed beer.
Naz, Iffat; Batool, Syeda Ain-ul; Ali, Naeem; Khatoon, Nazia; Atiq, Niama; Hameed, Abdul; Ahmed, Safia
2013-08-01
The present research work monitored the successive biofilm development and its catabolic role in the degradation of polystyrene (PS). PS material was artificially colonized with biofilm by incubating it with activated sludge under aerobic and anaerobic conditions. Biofilm formation was monitored by gravimetric weight analysis, spectrophotometric absorbance technique, heterotrophic plate count, and scanning electron microscopy under aerobic and anaerobic conditions. The wet weight (1.59 and 1.17 g) and dry weight (0.41 and 0.08 g) of a biofilm showed a significant constant increase under aerobic and anaerobic conditions, respectively, from first till 9 weeks of incubation. Plate count of the selected bacteria (Escherichia coli, Salmonella typhimurium, Shigella dysenteriae, Pseudomonas aeruginosa) considerably declined (90-99 %) in the biofilm after seventh and fifth weeks of incubation under aerobic and anaerobic conditions, respectively, indicating a positive shift from pathogenic to beneficial microbial community. While most probable number index of fecal coliforms and E. coli in the sludge showed more reduction (98 and 99 %) under aerobic as compare to anaerobic conditions (86 and 91 %) after 9 weeks of biofilm formation on PS cubes. Correspondingly, the decreasing levels of chemical oxygen demand and biochemical oxygen demand (up to 73 %) showed signs of sludge digestion. Scanning electron microscope coupled with energy dispersive X-ray spectroscope revealed nature of PS media containing high carbon content. However, biofilm development proved to be involved in the biochemical transformation of the PS medium as indicated by Fourier transform infrared spectroscopy.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sinclair, Michael B.; Caldwell, Sara; Jones, Howland D. T.
2005-12-01
Basic research is needed to better understand the potential risk of dangerous biological agents that are unintentionally or intentionally introduced into a water distribution system. We report on our capabilities to conduct such studies and our preliminary investigations. In 2004, the Biofilms Laboratory was initiated for the purpose of conducting applied research related to biofilms with a focus on application, application testing and system-scale research. Capabilities within the laboratory are the ability to grow biofilms formed from known bacteria or biofilms from drinking water. Biofilms can be grown quickly in drip-flow reactors or under conditions more analogous to drinking-water distributionmore » systems in annular reactors. Biofilms can be assessed through standard microbiological techniques (i .e, aerobic plate counts) or with various visualization techniques including epifluorescent and confocal laser scanning microscopy and confocal fluorescence hyperspectral imaging with multivariate analysis. We have demonstrated the ability to grow reproducible Pseudomonas fluorescens biofilms in the annular reactor with plate counts on the order of 10{sup 5} and 10{sup 6} CFU/cm{sup 2}. Stationary phase growth is typically reached 5 to 10 days after inoculation. We have also conducted a series of pathogen-introduction experiments, where we have observed that both polystyrene microspheres and Bacillus cereus (as a surrogate for B. anthracis) stay incorporated in the biofilms for the duration of our experiments, which lasted as long as 36 days. These results indicated that biofilms may act as a safe harbor for bio-pathogens in drinking water systems, making it difficult to decontaminate the systems.« less
García, R.; Bælum, J.; Fredslund, L.; Santorum, P.; Jacobsen, C. S.
2010-01-01
The effects of three temperatures (5, 15, and 25°C) on the survival of Salmonella enterica serovar Typhimurium in topsoil were investigated in small microcosms by three different techniques: plate counting, invA gene quantification, and invA mRNA quantification. Differences in survival were related to the effect of protozoan predation. Tetracycline-resistant Salmonella serovar Typhimurium was inoculated into soil and manure-amended soil at 1.5 × 108 cells g soil−1. Population densities were determined by plate counting and by molecular methods and monitored for 42 days. Simultaneous extraction of RNA and DNA, followed by quantitative PCR, was used to investigate invA gene levels and expression. Analysis by these three techniques showed that Salmonella serovar Typhimurium survived better at 5°C. Comparing DNA and CFU levels, significantly higher values were determined by DNA-based techniques. invA mRNA levels showed a fast decrease in activity, with no detectable mRNA after an incubation period of less than 4 days in any of the soil scenarios. A negative correlation was found between Salmonella serovar Typhimurium CFU levels and protozoan most probable numbers, and we propose the role of the predator-prey interaction as a factor to explain the die-off of the introduced strain by both culture- and DNA quantification-based methods. The results indicate that temperature, manure, and protozoan predation are important factors influencing the survival of Salmonella serovar Typhimurium in soil. PMID:20562283
Bacteriological Survey of Fresh Pork Sausage Produced at Establishments Under Federal Inspection1
Surkiewicz, Bernard F.; Johnston, Ralph W.; Elliott, R. Paul; Simmons, E. Ruth
1972-01-01
At the time of manufacture, 75% of 67 sets of finished fresh pork sausage collected in 44 plants had aerobic plate counts in the range of 500,000 or fewer/g; 88% contained 100 or fewer E. coli/g; and 75% contained 100 or fewer S. aureus/g (geometric means of 10 samples). Salmonellae were isolated from 28% of 529 samples of pork trimmings used for sausage, and from 28% of 560 finished sausage samples. Semiquantitative analysis revealed that salmonellae were at low levels; more than 80% of the salmonellae-positive samples were positive only in 25-g portions (negative in 1.0- and 0.1-g portions). PMID:4553799
NASA Astrophysics Data System (ADS)
Ahn, Jae-Jun; Akram, Kashif; Kwak, Ji-Young; Jeong, Mi-Seon; Kwon, Joong-Ho
2013-10-01
Cost-effective and time-efficient analytical techniques are required to screen large food lots in accordance to their irradiation status. Gamma-irradiated (0-10 kGy) cinnamon, red pepper, black pepper, and fresh paprika were investigated using photostimulated luminescence (PSL), direct epifluorescent filter technique/the aerobic plate count (DEFT/APC), and electronic-nose (e-nose) analyses. The screening results were also confirmed with thermoluminescence analysis. PSL analysis discriminated between irradiated (positive, >5000 PCs) and non-irradiated (negative, <700 PCs) cinnamon and red peppers. Black pepper had intermediate results (700-5000 PCs), while paprika had low sensitivity (negative results) upon irradiation. The DEFT/APC technique also showed clear screening results through the changes in microbial profiles, where the best results were found in paprika, followed by red pepper and cinnamon. E-nose analysis showed a dose-dependent discrimination in volatile profiles upon irradiation through principal component analysis. These methods can be used considering their potential applications for the screening analysis of irradiated foods.
Zhao, Y; Kumar, M; Caspers, M P M; Nierop Groot, M N; van der Vossen, J M B M; Abee, T
2018-02-01
Thermophilic bacilli such as Anoxybacillus and Geobacillus are important contaminants in dairy powder products. Remarkably, one of the common contaminants, Geobacillus thermoglucosidans, showed poor growth in skim milk, whereas significant growth of G. thermoglucosidans was observed in the presence of an Anoxybacillus flavithermus dairy isolate. In the present study, we investigated the underlying reason for this growth dependence of G. thermoglucosidans. Whole-genome sequences of 4 A. flavithermus strains and 4 G. thermoglucosidans strains were acquired, with special attention given to carbohydrate utilization clusters and proteolytic enzymes. Focusing on traits relevant for dairy environments, comparative genomic analysis revealed that all G. thermoglucosidans strains lacked the genes necessary for lactose transport and metabolism, showed poor growth in skim milk, and produced white colonies on X-gal plates, indicating the lack of β-galactosidase activity. The A. flavithermus isolates scored positive in these tests, consistent with the presence of a putative lactose utilization gene cluster. All tested isolates from both species showed proteolytic activity on milk plate count agar plates. Adding glucose or galactose to liquid skim milk supported growth of G. thermoglucosidans isolates, in line with the presence of the respective monosaccharide utilization gene clusters in the genomes. Analysis by HPLC of A. flavithermus TNO-09.006 culture filtrate indicated that the previously described growth dependence of G. thermoglucosidans in skim milk was based on the supply of glucose and galactose by A. flavithermus TNO-09.006. Copyright © 2018 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
Okamoto, K; Rhee, Y; Schoeny, M; Lolans, K; Cheng, J; Reddy, S; Weinstein, R A; Hayden, M K; Popovich, K J
2018-01-01
To compare two culture methods [nylon fiber flocked swabs with broth enrichment versus RODAC ('replicate organism detection and counting') plates] for recovery of multidrug-resistant organisms, 780 environmental surfaces in 63 rooms of patients on contact precautions in four intensive care units at one hospital were examined. Among sites that had at least one positive culture, swab culture with broth enrichment detected the target organisms more frequently than RODAC plates (37.5% vs 26.0%, P = 0.06). There was moderate agreement between the two methods (κ = 0.44) with agreement better for small or flat surfaces compared to large or irregular surfaces. Copyright © 2017 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.
Weiser, H; Vitz, R C; Moos, H W; Weinstein, A
1976-12-01
An evacuated high transmission prism spectrograph using a microchannel plate detection system with resistive strip readout was flown behind a precision pointing telescope on a sounding rocket. The construction, preparation, flight performance, and calibration stability of the system are discussed. Despite the adverse environmental conditions associated with sounding rocket flights, the microchannel detector system performed well. Far uv spectra (1160-1750 A) of stellar and planetary objects were obtained; spectral features with fluxes as low as 0.06 photons cm(-2) sec(-1) were detectable. This was achieved by operating the plates at lower than normal gains, using sensitive pulse counting electronics with both upper and lower limit discriminators, and maintaining the spectrograph and detector at a pressure of ~10(-6) Torr until reaching altitude.
The Role of Flushing Dental Waterlines for the Removal of Microbial Contaminants - MCEARD
Objectives. This study was designed to determine the role of flushing dental water lines for the removal of heterotrophic plate count bacteria, Legionella spp., and free-living protozoa. Methods. Forty dental offices were surveyed in the study. An initial sample and a sample tak...
Two second-order transformation rate coefficients--kb, based on total plate counts, and kA, based on periphyton-colonized surface areas--were used to compare xenobiotic chemical transformation by laboratory-developed (microcosm) and by field-collected microbiota. Similarity of tr...
EFFECT OF AEROSOLIZATION ON CULTURABILITY AND VIABILITY OF GRAM-NEGATIVE BACTERIA
Estimations of the bacterial content of air can be more easily made now than a decade ago, with colony formation the method of choice for enumeration of airborne bacteria.However, plate counts are subject to error because bacteria exposed to the air may remain viable yet lose the...
Bacterial Cleanability of Various Types of Eating Surfaces.
ERIC Educational Resources Information Center
Ridenour, Gerald M.; Armbruster, E. H.
1953-01-01
Presents a study of the capability of commercial dishwashers to remove bacteria from various kinds of service plates. Gives an account of preliminary research on the bacterial cleanability of eating surfaces of different materials by two radiological procedures--(1) radiological count, and (2) autoradiographic measurement. Among the factors…
Automated agar plate streaker: a linear plater on Society for Biomolecular Sciences standard plates.
King, Gregory W; Kath, Gary S; Siciliano, Sal; Simpson, Neal; Masurekar, Prakash; Sigmund, Jan; Polishook, Jon; Skwish, Stephen; Bills, Gerald; Genilloud, Olga; Peláez, Fernando; Martín, Jesus; Dufresne, Claude
2006-09-01
Several protocols for bacterial isolation and techniques for aerobic plate counting rely on the use of a spiral plater to deposit concentration gradients of microbial suspensions onto a circular agar plate to isolate colony growth. The advantage of applying a gradient of concentrations across the agar surface is that the original microbiological sample can be applied at a single concentration rather than as multiple serial dilutions. The spiral plater gradually dilutes the sample across a compact area and therefore saves time preparing dilutions and multiple agar plates. Commercial spiral platers are not automated and require manual sample loading. Dispensing of the sample volume and rate of gradients are often very limited in range. Furthermore, the spiral sample application cannot be used with rectangular microplates. Another limitation of commercial spiral platers is that they are useful only for dilute, filtered suspensions and cannot plate suspensions of coarse organic particles therefore precluding the use of many kinds of microorganism-containing substrata. An automated agar plate spreader capable of processing 99 rectangular microplates in unattended mode is described. This novel instrument is capable of dispensing discrete volumes of sample in a linear pattern. It can be programmed to dispense a sample suspense at a uniform application rate or across a decreasing concentration gradient.
MacDonald, David S; Waterfield, J Douglas
2011-01-01
The detectors (both solid-state sensors and photostimulable phosphor [PSP] plates) used for digital intraoral radiography cannot be autoclaved, and barriers are typically used to prevent the spread of infection. The aim of this study was to determine the effectiveness of a barrier envelope system for PSP plates. Disinfected PSP plates were aseptically inserted into barrier envelopes and placed in a periapical location. One PSP plate was placed in each of 28 patients, and 12 plates in each of 2 volunteers (D.S.M., J.D.W.). After retrieval, each PSP plate was removed from its barrier envelope, immersed in trypticase soy broth and aliquots were plated on trypticase soy agar. Bacterial colonies were counted 2 days later. Fifty-two PSP plates in barrier envelopes were evaluated for contamination. Quality assurance of the PSP plates before clinical placement revealed defects in the integrity of 4 barrier envelopes, caused by forceps-related damage or failure to achieve a uniform seal. These defects allowed substantial contamination. Contamination also occurred as a result of failure to extract the PSP plate from the barrier envelope cleanly. Of the 44 barriers with no obvious defects that were placed by either final-year dental students or a radiologist, only 3 allowed bacterial contamination of the PSP plate. Detectors contained in barrier envelopes remain a potential source of contamination. PSP plates must be disinfected between removal from a contaminated barrier envelope and placement in a new barrier envelope. In addition, placement into the barrier envelope should ideally be carried out under aseptic conditions. Finally, the integrity of each sealed barrier envelope must be verified visually before release to the clinic.
Applications of chemiluminescence to bacterial analysis
NASA Technical Reports Server (NTRS)
Searle, N. D.
1975-01-01
Luminol chemiluminescence method for detecting bacteria was based on microbial activation of the oxidation of the luminol monoanion by hydrogen peroxide. Elimination of the prior lysing step, previously used in the chemiluminescence technique, was shown to improve considerably the reproducibility and accuracy of the method in addition to simplifying it. An inexpensive, portable photomultiplier detector was used to measure the maximum light intensity produced when the sample is added to the reagent. Studies of cooling tower water show that the luminol chemiluminescence technique can be used to monitor changes in viable cell population both under normal conditions and during chlorine treatment. Good correlation between chemiluminescence and plate counts was also obtained in the analysis of process water used in paper mills. This method showed good potential for monitoring the viable bacteria populations in activated sludge used in waste treatment plants to digest organic matter.
Arslan, Sultan; Durak, Atike N; Erbas, Mustafa; Tanriverdi, Emel; Gulcan, Ummugulsum
2015-01-01
The aim of research was producing boza as a probiotic product with certificated probiotic starter cultures (Lactobacillus acidophilus LA-5 and Bifidobacterium bifidum BB-12 and Saccharomyces boulardii). Analysis were done in boza samples taken in fermentation and storage. Probiotic and non-probiotic bacteria were enumerated with pour plate technique and yeast enumerated spread plate technique. Sugar, organic acid and Water soluble vitamin content were determined by using of HPLC. Sensory analyses were done by two different types of panels, once comprised of trained panelists and the other of consumers. Shelf life was determined according the results of sensory analysis. It was determinated that S. boulardii and L acidophilius counts increased nearly 0.5 log unit during of boza fermentation. Lactic, acetic, citric, butyric and succinic acid as organic acids and thiamin, niacin, B6 and pantothenic acid as water soluble vitamin evaluated in boza samples. Shelf life of the probiotic boza determined as 12 days at +4°C fridge storage temperature. The boza samples had a probiotic effect because it had viable microorganisms more than 10(6) cfu/ml which was defined enough for functional foods. All boza samples had lower pH value than 4.5, so it is evaluated that boza is a safety food as its low pH preventing pathogen growth.
Photon-counting image sensors for the ultraviolet
NASA Technical Reports Server (NTRS)
Jenkins, E. B.
1985-01-01
An investigation on specific performance details of photon counting, ultraviolet image sensors having 2-dimensional formats is reviewed. In one study, controlled experiments were performed which compare the quantum efficiencies, in pulse counting mode, of CsI photocathodes deposited on: (1) the front surface of a microchannel plate (MCP), (2) a solid surface in front of an MCP, and (3) an intensified CCD image sensor (ICCD) where a CCD is directly bombarded by accelerated photoelectrons. Tests indicated that the detection efficiency of the CsI-coated MCP at 1026 A is lower by a factor of 2.5 than that of the MCP with a separate, opaque CsI photocathode, and the detection efficiency ratio increases substantially at longer wavelengths (ratio is 5 at 1216 A and 20 at 1608 A).
Microbial evaluation of Alaska salmon caviar.
Himelbloom, B H; Crapo, C A
1998-05-01
Microbial quality of pink salmon caviar (ikura) processed at one plant in Alaska during a 30-day season was examined. Ikura (aw = 0.98; pH 6.1) averaged 49% water, 32% protein, 11% fat, 7% ash, and 3% salt. Aerobic plate counts (APCs) ranged from < 10(2)/g to 4.5 x 10(7)/g with increasing APC toward season's end. Coliform counts ranged from < 3/g to 2.4 x 10(3)/g. Escherichia coli, Staphylococcus aureus, yeasts, and molds were not detected. High-APC (10(7)/g) thawed caviar exhibited predominantly lactic acid bacteria; low-APC (10(3)/g) thawed caviar exhibited predominantly gram-negative bacteria. Freezing had little effect on the microbial counts, and shelf life of thawed caviar was 3 to 5 days at 2 degrees C.
Monitoring process hygiene in Serbian retail establishments
NASA Astrophysics Data System (ADS)
Vesković Moračanin, S.; Baltić, T.; Milojević, L.
2017-09-01
The present study was conducted to estimate the effectiveness of sanitary procedures on food contact surfaces and food handlers’ hands in Serbian retail establishments. For that purpose, a total of 970 samples from food contact surfaces and 525 samples from workers’ hands were microbiologically analyzed. Results of total aerobic plate count and total Enterobacteriaceae count showed that the implemented washing and disinfection procedures, as a part of HACCP plans, were not effective enough in most retail facilities. Constant and intensive education of employees on proper implementation of sanitation procedures are needed in order to ensure food safety in the retail market.
Photon-Counting H33D Detector for Biological Fluorescence Imaging
Michalet, X.; Siegmund, O.H.W.; Vallerga, J.V.; Jelinsky, P.; Millaud, J.E.; Weiss, S.
2010-01-01
We have developed a photon-counting High-temporal and High-spatial resolution, High-throughput 3-Dimensional detector (H33D) for biological imaging of fluorescent samples. The design is based on a 25 mm diameter S20 photocathode followed by a 3-microchannel plate stack, and a cross delay line anode. We describe the bench performance of the H33D detector, as well as preliminary imaging results obtained with fluorescent beads, quantum dots and live cells and discuss applications of future generation detectors for single-molecule imaging and high-throughput study of biomolecular interactions. PMID:20151021
Bhat, Rajeev
2016-12-15
Impact of ultraviolet (UV-C) radiation treatments (0, 15, 30 and 60min) on freshly extracted tomato juice quality (physicochemical properties, antioxidant activity and microbial load) was evaluated. On exposure to UV-C, level of water activity, total soluble solids, and titratable acidity exhibited non-significant increase up to 30min of exposure time. Regarding colour analysis, L∗ value significantly increased with subsequent decrease in a∗ and b∗ values post UV-C treatments. Clarity, DPPH (1,1-diphenyl-2-picrylhydrazyl) radical scavenging activity and total phenolics content significantly increased, whereas ascorbic acid level significantly reduced at 60min of UV-C exposure time. So also, lycopene content exhibited a non-significant decrease after UV-C treatment. Microbial studies showed reduction in total plate count and total mould counts post UV-C treatment. Overall, UV-C treatment being a physical, non-thermal method of food preservation holds the ability to improve or preserve vital quality parameters in freshly prepared tomato juices, and henceforth possesses high scope for commercial exploration. Copyright © 2016 Elsevier Ltd. All rights reserved.
Cicconi-Hogan, K M; Gamroth, M; Richert, R; Ruegg, P L; Stiglbauer, K E; Schukken, Y H
2013-01-01
The purpose of this study was to assess the association of bulk tank milk standard plate counts, bulk tank coliform counts (CC), and the presence of Staphylococcus aureus in bulk tank milk with various management and farm characteristics on organic and conventional dairy farms throughout New York, Wisconsin, and Oregon. Data from size-matched organic farms (n=192), conventional nongrazing farms (n=64), and conventional grazing farms (n=36) were collected at a single visit for each farm. Of the 292 farms visited, 290 bulk tank milk samples were collected. Statistical models were created using data from all herds in the study, as well as exclusively for the organic subset of herds. Because of incomplete data, 267 of 290 herds were analyzed for total herd modeling, and 173 of 190 organic herds were analyzed for the organic herd modeling. Overall, more bulk tanks from organic farms had Staph. aureus cultured from them (62% of organic herds, 42% conventional nongrazing herds, and 43% of conventional grazing herds), whereas fewer organic herds had a high CC, defined as ≥50 cfu/mL, than conventional farms in the study. A high standard plate count (×1,000 cfu/mL) was associated with decreased body condition score of adult cows and decreased milk production in both models. Several variables were significant only in the model created using all herds or only in organic herds. The presence of Staph. aureus in the bulk tank milk was associated with fewer people treating mastitis, increased age of housing, and a higher percentage of cows with 3 or fewer teats in both the organic and total herd models. The Staph. aureus total herd model also showed a relationship with fewer first-lactation animals, higher hock scores, and less use of automatic takeoffs at milking. High bulk tank CC was related to feeding a total mixed ration and using natural service in nonlactating heifers in both models. Overall, attentive management and use of outside resources were useful with regard to CC on organic farms. In all models except the organic CC model, we observed an association with the average reported somatic cell count from 3 mo before the herd visit, indicating that many of the regularly tested milk quality parameters are interconnected. In conclusion, we found that conventional and organic farms are similar in regard to overall herd management, but each grazing system faces unique challenges when managing milk quality. Copyright © 2013 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
Pianetti, Anna; Manti, Anita; Boi, Paola; Citterio, Barbara; Sabatini, Luigia; Papa, Stefano; Rocchi, Marco Bruno Luigi; Bruscolini, Francesca
2008-10-31
Aeromonads in waters and foods can represent a risk to human health. Factors such as sodium chloride concentration and temperature can affect growth and viability of several food and water-borne pathogens. The behaviour of an Aeromonas hydrophila strain in the presence of 1.7%, 3.4% and 6% NaCl concentrations at 24 degrees C and 4 degrees C was studied over a 188 day period. Viability and membrane potential were assessed by flow cytometry; growth was evaluated by plate count technique. Flow cytometry evidenced that A. hydrophila retained viability over the period although varying according to temperature and salt concentrations. Colony Forming Units were generally lower in number than viable cells especially in the presence of 6% NaCl, indicating the occurrence of stressed cells which maintain metabolic activity yet are not able to grow on agar plates. In conclusion, A. hydrophila showed a long-term halotolerance even at elevated (6%) NaCl concentrations and a lesser sensitivity to salt at low temperature; therefore, low temperature and salt, which are two important factors limiting bacterial growth, do not assure safety in the case of high initial contamination. Finally, cytometry appears a valid tool for the rapid detection of the viability of pathogenic bacteria in food and environmental matrices to control and prevent health risks.
Survival of B. Horneckiae Spores Under Ground-simulated Space Conditions
NASA Technical Reports Server (NTRS)
Schanche, Bradley
2012-01-01
To prevent forward contamination and maintain the scientific integrity of future life detection missions, it is important to characterize and attempt to eliminate terrestrial microorganisms associated with exploratory spacecraft and landing vehicles. Among the organisms isolated from spacecraft-associated habitats, spore-forming microbes are highly resistant to various physical and chemical conditions, which include ionizing and UV radiation, desiccation and oxidative stress, and the harsh environment of outer space or planetary surfaces. Recently a radiation resistant, spore forming bacterial isolate, Bacillus horneckiae, was isolated from a clean room of the Kennedy Space Center where the Phoenix spacecraft was assembled. The exceptionally high tolerance of extreme conditions demonstrated by sporeforming bacteria highlighted the need to assess the viability of these microbes in situ (in real) space. The proposed BOSS (Biofilm Organisms Surfing Space) project aims to understand the mechanisms by which biofilm forming organisms, such as B. horneckiae, will potentially be able to withstand harsh space conditions. As previously stated, the spore producing ability of these species gives them increased survivability to harsh conditions. Some of the spores will have the protective exosporium layer artificially removed before the test to determine if the existence of this layer significantly changes the survivability during the mission. In preparation for that experiment, we analyzed spores which were exposed during a ground simulation, the EXPOSE R2 Biofilm Organisms Surfing Space (BOSS). Previous to exposure, spores were deposited onto spacecraft grade aluminum coupons in a spore suspension calculated to contain between 10(exp 7) and 10(exp 8) spores. This precursor series will be used to establish a baseline survivability function for comparison with the future flight tests during EXPOSE-R. For each coupon, a 10% polyvinyl alcohol (PVA) film was applied and peeled from the coupon to recover the spores. One hundred µl of sterile 10% PVA was applied to the surface of the coupon and allowed to dry for 1 hour at 37 C. The films were then removed using sterile scalpel and forceps and placed into a glass test tube containing 2 milliliters of sterile deionized water. The PVA film process was then repeated on each coupon one additional time to ensure recovery of the majority of spores. The second PVA film was added in the same glass tube as in the previous round. If the spores remained 100% viable, the test tubes should now contain between 5 X 10(exp 6) and 5 X 10(exp 7) spores per millimeter; however, it is expected that some loss of viability has occurred. In order to assess this loss, the number of colony forming, viable spores was counted. To count the colony forming units (CFUs), the spore containing solution was diluted in a process of 10-fold serial dilution by mixing successive solutions in a 100 microliter spore suspension to 900 microliter deionized H2O ratio. A sample dilution series revealed that 10(exp -3) and 10(exp -4) concentrations would be necessary for an accurate CFU count to be taken. For those two concentrations, a spread on a TSA plate was prepared and incubated at 32 C. For the samples exposed to UV radiation, the cell survivability was too low to establish a count from 100 microliter spread plating. Instead, no dilutions were performed and the entire 2 milliliter spore suspension was plated and incubated at 32 C. The plate's CFU counts were taken at 24 hours and 48 hours from the time of plating. At the end of the CFU counting the total surviving spores in each sample were calculated based on the number of CFUs that were observed per 100 microliters, or per 2 milliliters for the UV irradiated samples. The results of these calculations are shown in Figures 1 and 2.
Microbiological quality of drinking water from dispensers in roadside restaurants of Bangladesh.
Moniruzzaman, M; Akter, S; Islam, M A; Mia, Z
2011-01-15
The microbiological status of water from dispensers in different roadside restaurants of Dhaka city and Savar area was analyzed in this study. Seven samples from Dhaka and 8 samples of Savar were checked. The heterotrophic plate count was in a range of 1.0 x 10(3) CFU mL(-1) to 2.0 x 10(4) CFU mL(-1) (from new bottles), 1.0 x 10(3) to 1.5 x 10(4) CFU mL(-1) (after dispensation), and 1.5 x 10(3) CFU mL(-1) to 1.0 x l0(5) CFU mL(-1) (from serving glass). In several of the samples, the heterotrophic plate count was higher than the count in water from new bottle or after dispensation, suggesting added contamination from the serving glass. 80% of the samples were contaminated with total and fecal coliform bacteria, which render these waters unacceptable for human consumption. The samples were found to contain gram negative bacteria like E coli, Shigella sp., Klebsiella sp., Enterobacter sp., Pseudomonas sp., and Salmonella sp., which are potential pathogens and thus pose a serious threat to public health. This study elucidates the importance of monitoring the bottling companies and the restaurants and put them under strict regulations to prevent future outbreak of any water borne diseases caused by consumption of dispensed water.
Stress-opioid interactions: a comparison of morphine and methadone.
Taracha, Ewa; Mierzejewski, Paweł; Lehner, Małgorzata; Chrapusta, Stanisław J; Kała, Maria; Lechowicz, Wojciech; Hamed, Adam; Skórzewska, Anna; Kostowski, Wojciech; Płaźnik, Adam
2009-01-01
The utility of methadone and morphine for analgesia and of methadone for substitution therapy for heroin addiction is a consequence of these drugs acting as opioid receptor agonists.We compared the cataleptogenic and antinociceptive effects of single subcutaneous doses of methadone hydrochloride (1-4 mg/kg) and morphine sulfate (2.5-10 mg/kg) using catalepsy and hot-plate tests, and examined the effects of the highest doses of the drugs on Fos protein expression in selected brain regions in male Sprague-Dawley rats. Methadone had greater cataleptogenic and analgesic potency than morphine. Fos immunohistochemistry revealed substantial effects on the Fos response of both the stress induced by the experimental procedures and of the drug exposure itself. There were three response patterns identified: 1) drug exposure, but not stress, significantly elevated Fos-positive cell counts in the caudate-putamen; 2) stress alone and stress combined with drug exposure similarly elevated Fos-positive cell counts in the nucleus accumbens and cingulate cortex; and 3) methadone and morphine (to a lesser extent) counteracted the stimulatory effect of nonpharmacological stressors on Fos protein expression in the somatosensory cortex barrel field, and Fos-positive cell counts in this region correlated negatively with both the duration of catalepsy and the latency time in the hot-plate test. The overlap between brain regions reacting to nonpharmacological stressors and those responding to exogenous opioids suggests that stress contributes to opioid-induced neuronal activation.
Lehtola, Markku J; Miettinen, Ilkka T; Hirvonen, Arja; Vartiainen, Terttu; Martikainen, Pertti J
2007-12-01
The numbers of bacteria generally increase in distributed water. Often household pipelines or water fittings (e.g., taps) represent the most critical location for microbial growth in water distribution systems. According to the European Union drinking water directive, there should not be abnormal changes in the colony counts in water. We used a pilot distribution system to study the effects of water stagnation on drinking water microbial quality, concentration of copper and formation of biofilms with two commonly used pipeline materials in households; copper and plastic (polyethylene). Water stagnation for more than 4h significantly increased both the copper concentration and the number of bacteria in water. Heterotrophic plate counts were six times higher in PE pipes and ten times higher in copper pipes after 16 h of stagnation than after only 40 min stagnation. The increase in the heterotrophic plate counts was linear with time in both copper and plastic pipelines. In the distribution system, bacteria originated mainly from biofilms, because in laboratory tests with water, there was only minor growth of bacteria after 16 h stagnation. Our study indicates that water stagnation in the distribution system clearly affects microbial numbers and the concentration of copper in water, and should be considered when planning the sampling strategy for drinking water quality control in distribution systems.
Salvador, Angelo C; Baptista, Inês; Barros, António S; Gomes, Newton C M; Cunha, Angela; Almeida, Adelaide; Rocha, Silvia M
2013-01-01
A novel approach based on headspace solid-phase microextraction (HS-SPME) combined with comprehensive two-dimensional gas chromatography-time-of-flight mass spectrometry (GC×GC-ToFMS) was developed for the simultaneous screening of microbial and mite contamination level in cereals and coffee beans. The proposed approach emerges as a powerful tool for the rapid assessment of the microbial contamination level (ca. 70 min versus ca. 72 to 120 h for bacteria and fungi, respectively, using conventional plate counts), and mite contamination (ca. 70 min versus ca. 24 h). A full-factorial design was performed for optimization of the SPME experimental parameters. The methodology was applied to three types of rice (rough, brown, and white rice), oat, wheat, and green and roasted coffee beans. Simultaneously, microbiological analysis of the samples (total aerobic microorganisms, moulds, and yeasts) was performed by conventional plate counts. A set of 54 volatile markers was selected among all the compounds detected by GC×GC-ToFMS. Principal Component Analysis (PCA) was applied in order to establish a relationship between potential volatile markers and the level of microbial contamination. Methylbenzene, 3-octanone, 2-nonanone, 2-methyl-3-pentanol, 1-octen-3-ol, and 2-hexanone were associated to samples with higher microbial contamination level, especially in rough rice. Moreover, oat exhibited a high GC peak area of 2-hydroxy-6-methylbenzaldehyde, a sexual and alarm pheromone for adult mites, which in the other matrices appeared as a trace component. The number of mites detected in oat grains was correlated to the GC peak area of the pheromone. The HS-SPME/GC×GC-ToFMS methodology can be regarded as the basis for the development of a rapid and versatile method that can be applied in industry to the simultaneous assessment the level of microbiological contamination and for detection of mites in cereals grains and coffee beans.
Salvador, Ângelo C.; Baptista, Inês; Barros, António S.; Gomes, Newton C. M.; Cunha, Ângela; Almeida, Adelaide; Rocha, Silvia M.
2013-01-01
A novel approach based on headspace solid-phase microextraction (HS-SPME) combined with comprehensive two-dimensional gas chromatography–time-of-flight mass spectrometry (GC×GC–ToFMS) was developed for the simultaneous screening of microbial and mite contamination level in cereals and coffee beans. The proposed approach emerges as a powerful tool for the rapid assessment of the microbial contamination level (ca. 70 min versus ca. 72 to 120 h for bacteria and fungi, respectively, using conventional plate counts), and mite contamination (ca. 70 min versus ca. 24 h). A full-factorial design was performed for optimization of the SPME experimental parameters. The methodology was applied to three types of rice (rough, brown, and white rice), oat, wheat, and green and roasted coffee beans. Simultaneously, microbiological analysis of the samples (total aerobic microorganisms, moulds, and yeasts) was performed by conventional plate counts. A set of 54 volatile markers was selected among all the compounds detected by GC×GC–ToFMS. Principal Component Analysis (PCA) was applied in order to establish a relationship between potential volatile markers and the level of microbial contamination. Methylbenzene, 3-octanone, 2-nonanone, 2-methyl-3-pentanol, 1-octen-3-ol, and 2-hexanone were associated to samples with higher microbial contamination level, especially in rough rice. Moreover, oat exhibited a high GC peak area of 2-hydroxy-6-methylbenzaldehyde, a sexual and alarm pheromone for adult mites, which in the other matrices appeared as a trace component. The number of mites detected in oat grains was correlated to the GC peak area of the pheromone. The HS-SPME/GC×GC–ToFMS methodology can be regarded as the basis for the development of a rapid and versatile method that can be applied in industry to the simultaneous assessment the level of microbiological contamination and for detection of mites in cereals grains and coffee beans. PMID:23613710
Bhaduri, Saumya; Cottrell, Bryan
2004-12-01
Campylobacter jejuni is prevalent in poultry, but the effect of combined refrigerated and frozen storage on its survival, conditions relevant to poultry processing and storage, has not been evaluated. Therefore, the effects of refrigeration at 4 degrees C, freezing at -20 degrees C, and a combination of refrigeration and freezing on the survival of C. jejuni in ground chicken and on chicken skin were examined. Samples were enumerated using tryptic soy agar containing sheep's blood and modified cefoperazone charcoal deoxycholate agar. Refrigerated storage alone for 3 to 7 days produced a reduction in cell counts of 0.34 to 0.81 log10 CFU/g in ground chicken and a reduction in cell counts of 0.31 to 0.63 log10 CFU/g on chicken skin. Declines were comparable for each sample type using either plating medium. Frozen storage, alone and with prerefrigeration, produced a reduction in cell counts of 0.56 to 1.57 log10 CFU/g in ground chicken and a reduction in cell counts of 1.38 to 3.39 log10 CFU/g on chicken skin over a 2-week period. The recovery of C. jejuni following freezing was similar on both plating media. The survival following frozen storage was greater in ground chicken than on chicken skin with or without prerefrigeration. Cell counts after freezing were lower on chicken skin samples that had been prerefrigerated for 7 days than in those that had been prerefrigerated for 0, 1, or 3 days. This was not observed for ground chicken samples, possibly due to their composition. C. jejuni survived storage at 4 and -20 degrees C with either sample type. This study indicates that, individually or in combination, refrigeration and freezing are not a substitute for safe handling and proper cooking of poultry.
NASA Astrophysics Data System (ADS)
Foley, D. M.; Dufour, A.; Rodriguez, L.; Caporaso, F.; Prakash, A.
2002-03-01
Lettuce was inoculated with a six-strain cocktail of acid-adapted Escherichia coli 0157:H7 at a level of 1×10 7 CFU/g. Following chlorination at 200 μg/ml, the lettuce was irradiated at 0.15, 0.38, or 0.55 kGy using a 60Co source. Survival of E. coli 0157:H7, aerobic mesophiles and yeast and molds were measured over a period of 10 days. For quality analysis, chlorinated lettuce was subjected to irradiation at 0.33 and 0.53 kGy and stored at 1.0°C, 4.0°C or 7.0°C. Changes in texture and color were determined by instrumental means and changes in flavor, odor, and visual quality were determined by sensory testing. Chlorination plus irradiation at 0.55 kGy produced a 5.4-log reduction in E. coli 0157:H7 levels. Chlorination alone reduced the E. coli 0157:H7 counts by 1-2 logs. Irradiation at 0.55 kGy was also effective in reducing standard plate counts and yeast and mold counts. Irradiation at this level did not cause softening of lettuce and sensory attributes were not adversely affected. In general, appearance and flavor were affected more by the length of storage than by temperature conditions. The 5+log reduction in E. coli counts and lack of adverse effects on sensory attributes indicate that low-dose irradiation can improve the safety and shelf-life of fresh-cut iceberg lettuce for retail sale or food service.
Ferreira, Fernanda Stoduto; Horvath, Mariana Bandeira; Tondo, Eduardo Cesar
2013-01-01
The objective of the present study was to assess the growth and the recovery of Salmonella (S.) Enteritidis SE86 in different diluents, culture media and using different plating methods after the exposure to 200 mg/kg sodium dichloroisocyanurate (NaDCC). Before and after NaDCC exposure, SE86 was cultured at 30 °C and 7 °C in the following diluents: Peptone water (P), Saline solution (SaS), Peptone water+Saline solution (P+SaS), Peptone water+Tween 80+Lecithin+Sodium thiosulfate (P+N) and Saline solution+Tween 80+Lecithin+Sodium thiosulfate (SaS+N). The SaS diluent was chosen because it was able to maintain cells viable without growth and was further used for plating SE86 on non selective medium (Tryptic Soy Agar-TSA) and on selective media (Mannitol Lysine Crystal Violet Brilliant Green Agar-MLCB; Brilliant Green Agar-BGA; Salmonella Shigella Agar-SS and Xylose Lysine Dextrose–XLD). The Thin Agar Layer method (TAL) i.e., selective media overlayed with non selective TSA was also evaluated. Results indicated that SE86 not exposed to NaDCC was able to grow in P, P+N, SaS+N and P+SaS, but not in SaS, that was able to maintain cells viable. SE86 exposed to NaDCC demonstrated similar counts after dilution in SaS and the plating on non selective TSA, selective media MLCB, BGA, SS and XLD and on TAL media. SE86, S. Typhimurium and S. Bredeney, exposed or not exposed to NaDCC, showed no significant differences in counts on TSA, XLD and XLD overlayed with TSA, suggesting that all those media may be used to quantify NaDCC-exposed Salmonella by plating method. PMID:24516446
Paludetti, Lizandra F; Kelly, Alan L; O'Brien, Bernadette; Jordan, Kieran; Gleeson, David
2018-03-01
The objective of this study was to measure the effect of different milk cooling rates, before entering the bulk tank, on the microbiological load and composition of the milk, as well as on energy usage. Three milk precooling treatments were applied before milk entered 3 identical bulk milk tanks: no plate cooler (NP), single-stage plate cooler (SP), and double-stage plate cooler (DP). These precooling treatments cooled the milk to 32.0 ± 1.4°C, 17.0 ± 2.8°C, and 6.0 ± 1.1°C, respectively. Milk was added to the bulk tank twice daily for 72 h, and the tank refrigeration temperature was set at 3°C. The blend temperature within each bulk tank was reduced after each milking event as the volume of milk at 3°C increased simultaneously. The bacterial counts of the milk volumes precooled at different rates did not differ significantly at 0 h of storage or at 24-h intervals thereafter. After 72 h of storage, the total bacterial count of the NP milk was 3.90 ± 0.09 log 10 cfu/mL, whereas that of the precooled milk volumes were 3.77 ± 0.09 (SP) and 3.71 ± 0.09 (DP) log 10 cfu/mL. The constant storage temperature (3°C) over 72 h helped to reduce bacterial growth rates in milk; consequently, milk composition was not affected and minimal, if any, proteolysis occurred. The DP treatment had the highest energy consumption (17.6 ± 0.5 Wh/L), followed by the NP (16.8 ± 2.7 Wh/L) and SP (10.6 ± 1.3 Wh/L) treatments. This study suggests that bacterial count and composition of milk are minimally affected when milk is stored at 3°C for 72 h, regardless of whether the milk is precooled; however, milk entering the tank should have good initial microbiological quality. Considering the numerical differences between bacterial counts, however, the use of the SP or DP precooling systems is recommended to maintain low levels of bacterial counts and reduce energy consumption. The Authors. Published by FASS Inc. and Elsevier Inc. on behalf of the American Dairy Science Association®. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/3.0/).
A rapid detection method using flow cytometry to monitor the risk of Legionella in bath water.
Taguri, Toshitsugu; Oda, Yasunori; Sugiyama, Kanji; Nishikawa, Toru; Endo, Takuro; Izumiyama, Shinji; Yamazaki, Masayuki; Kura, Fumiaki
2011-07-01
Legionella species are the causative agents of human legionellosis, and bathing facilities have been identified as the sources of infection in several outbreaks in Japan. Researchers in Japan have recently reported evidence of significant associations between bacterial counts and the occurrence of Legionella in bathing facilities and in a hot tub model. A convenient and quantitative bacterial enumeration method is therefore required as an indicator of Legionella contamination or disinfection to replace existing methods such as time-consuming Legionella culture and expensive Legionella-DNA amplification. In this study, we developed a rapid detection method (RDM) to monitor the risk of Legionella using an automated microbial analyzing device based on flow cytometry techniques to measure the total number of bacteria in water samples within two minutes, by detecting typical patterns of scattered light and fluorescence. We first compared the results of our RDM with plate counting results for five filtered hot spring water samples spiked with three species of bacteria, including Legionella. Inactivation of these samples by chlorine was also assessed by the RDM, a live/dead bacterial fluorescence assay and plate counting. Using the RDM, the lower limit of quantitative bacterial counts in the spiked samples was determined as 3.0×10(3)(3.48log)counts mL(-1). We then used a laboratory model of a hot tub and found that the RDM could monitor the growth curve of naturally occurring heterotrophic bacteria with 1 and 2 days' delayed growth of amoeba and Legionella, respectively, and could also determine the killing curve of these bacteria by chlorination. Finally, samples with ≥3.48 or <3.48log total bacterial counts mL(-1) were tested using the RDM from 149 different hot tubs, and were found to be significantly associated with the positive or negative detection of Legionella with 95% sensitivity and 84% specificity. These findings indicated that the RDM can be used for Legionella control at bathing facilities, especially those where the effectiveness of chlorine is reduced by the presence of Fe(2+), Mn(2+), NH(4)(+), skin debris, and/or biofilms in the water. Copyright © 2011 Elsevier B.V. All rights reserved.
Wang, Lei; Wu, Xiaobo; Qi, Wei; Wang, Yongbin; He, Quanjie; Xu, Fengsong; Liu, Hongyang
2015-10-01
To compare the biomechanical difference of 4 kinds of internal fixations for acetabular fracture in quadrilateral area. The transverse fracture models were created in 16 hemipelves specimens from 8 adult males, and were randomly divided into 4 groups according to different internal fixation methods (n = 4): infrapectineal buttress reconstruction plate (group A), infrapectineal buttress locking reconstruction plate (group B), reconstruction plate combined with trans-plate quadrilateral screws (group C), and anterior reconstruction plate-lag screw (group D). Then the horizontal displacement, longitudinal displacement of fractures, and axial stiffness were measured and counted to compare the stability after continuous vertical loading. Under the same loading, the horizontal and longitudinal displacements of groups A, B, C, and D were decreased gradually; when the loading reached 1 800 N, the longitudinal displacement of group A was more than 3.00 mm, indicating the failure criterion, while the axial stiffness increased gradually. Under 200 N loading, there was no significant difference (P > 0.05) in horizontal displacement, longitudinal displacement, and axial stiffness among 4 groups. When the loading reached 600-1 800 N, significant differences were found in horizontal displacement, longitudinal displacement, and axial stiffness among 4 groups (P < 0.05) except the horizontal displacement between groups C and D (P > 0.05). For acetabular fracture in the quadrilateral area, anterior reconstruction plate-lag screw for internal fixation has highest stability, followed by reconstruction plate combined with trans-plate quadrilateral screws, and they are better than infrapectineal buttress reconstruction plate and infrapectineal buttress locking reconstruction plate.
Multi-anode microchannel arrays
NASA Technical Reports Server (NTRS)
Timothy, J. G.; Bybee, R. L.
1977-01-01
A development program is currently being undertaken to produce photon-counting detector arrays which are suitable for use in both ground-based and space-borne instruments and which utilize the full sensitivity, dynamic range and photometric stability of the microchannel array plate (MCP). The construction of the detector arrays and the status of the development program are described.
Paper Plate Fractions: The Counting Connection
ERIC Educational Resources Information Center
McCoy, Ann; Barnett, Joann; Stine, Tammy
2016-01-01
Without a doubt, fractions prove to be a stumbling block for many children. Researchers have suggested a variety of explanations for why this is the case. The introduction of symbolization and operations before the development of conceptual understanding of fractions, a lack of understanding of the role of the numerator and denominator, and an…
Ivanova, L V; Artemova, T Z; Gipp, E K; Zagaĭnova, A V; Maksimkina, T N; Krasniak, A V; Korneĭchuk, S S; Shustova, S S
2013-01-01
For the purpose of harmonization of microbiological and parasitological indices and benchmarks there was performed the comparative analysis of the requirements for the quality of drinking water in respect of the epidemic safety on the basic regulations of Russia, the Directive Council of the European Union EU, WHO, the United States, Canada, Australia, Finland, Sweden, Brazil, France, Japan and China. As a result, there were revealed the priority bacteriological, virological and parasitological parameters: E. coli--indicator of recent fecal contamination, coliforms, heterotrophic bacteria colony count (Heterotrophic plate count), which is in the water legislation of the Russian Federation is characterized as total bacterial count (TBC), being an integral index of the quality of wastewater treatment technologies and hygienic condition of the water supply systems, coliphages as an indicator of viral contamination. In the Guidelines for drinking-water quality control, WHO and a set of countries there is recommended a more wide range of indicators: enterococci, Clostridium perfringens, Pseudomonas aeruginosa, enteroviruses, parasitological indices. With aim of harmonization of the requirements for the quality of drinking water in the Russian Federation with international approaches to the revision of the Sanitary Regulations and Norms (SanPin) 2.1.4.1074 into the project there are introduced priority indicator parameters of bacterial, viral and parasitic contamination of water, evidence-based guidelines.
Mendez, Javier; Monleon-Getino, Antonio; Jofre, Juan; Lucena, Francisco
2017-10-01
The present study aimed to establish the kinetics of the appearance of coliphage plaques using the double agar layer titration technique to evaluate the feasibility of using traditional coliphage plaque forming unit (PFU) enumeration as a rapid quantification method. Repeated measurements of the appearance of plaques of coliphages titrated according to ISO 10705-2 at different times were analysed using non-linear mixed-effects regression to determine the most suitable model of their appearance kinetics. Although this model is adequate, to simplify its applicability two linear models were developed to predict the numbers of coliphages reliably, using the PFU counts as determined by the ISO after only 3 hours of incubation. One linear model, when the number of plaques detected was between 4 and 26 PFU after 3 hours, had a linear fit of: (1.48 × Counts 3 h + 1.97); and the other, values >26 PFU, had a fit of (1.18 × Counts 3 h + 2.95). If the number of plaques detected was <4 PFU after 3 hours, we recommend incubation for (18 ± 3) hours. The study indicates that the traditional coliphage plating technique has a reasonable potential to provide results in a single working day without the need to invest in additional laboratory equipment.
VizieR Online Data Catalog: Tidal radii of 7 globular clusters (Lehmann+ 1997)
NASA Astrophysics Data System (ADS)
Lehmann, I.; Scholz, R.-D.
1998-02-01
We present new tidal radii for seven Galactic globular clusters using the method of automated star counts on Schmidt plates of the Tautenburg, Palomar and UK telescopes. The plates were fully scanned with the APM system in Cambridge (UK). Special account was given to a reliable background subtraction and the correction of crowding effects in the central cluster region. For the latter we used a new kind of crowding correction based on a statistical approach to the distribution of stellar images and the luminosity function of the cluster stars in the uncrowded area. The star counts were correlated with surface brightness profiles of different authors to obtain complete projected density profiles of the globular clusters. Fitting an empirical density law (King 1962AJ.....67..471K) we derived the following structural parameters: tidal radius rt, core radius rc and concentration parameter c. In the cases of NGC 5466, M 5, M 12, M 13 and M 15 we found an indication for a tidal tail around these objects (cf. Grillmair et al., 1995AJ....109.2553G). (1 data file).
Evaluation of quantitative PCR measurement of bacterial colonization of epithelial cells.
Schmidt, Marcin T; Olejnik-Schmidt, Agnieszka K; Myszka, Kamila; Borkowska, Monika; Grajek, Włodzimierz
2010-01-01
Microbial colonization is an important step in establishing pathogenic or probiotic relations to host cells and in biofilm formation on industrial or medical devices. The aim of this work was to verify the applicability of quantitative PCR (Real-Time PCR) to measure bacterial colonization of epithelial cells. Salmonella enterica and Caco-2 intestinal epithelial cell line was used as a model. To verify sensitivity of the assay a competition of the pathogen cells to probiotic microorganism was tested. The qPCR method was compared to plate count and radiolabel approach, which are well established techniques in this area of research. The three methods returned similar results. The best quantification accuracy had radiolabel method, followed by qPCR. The plate count results showed coefficient of variation two-times higher than this of qPCR. The quantitative PCR proved to be a reliable method for enumeration of microbes in colonization assay. It has several advantages that make it very useful in case of analyzing mixed populations, where several different species or even strains can be monitored at the same time.
Bacteria associated with granular activated carbon particles in drinking water.
Camper, A K; LeChevallier, M W; Broadaway, S C; McFeters, G A
1986-01-01
A sampling protocol was developed to examine particles released from granular activated carbon filter beds. A gauze filter/Swinnex procedure was used to collect carbon fines from 201 granular activated carbon-treated drinking water samples over 12 months. Application of a homogenization procedure (developed previously) indicated that 41.4% of the water samples had heterotrophic plate count bacteria attached to carbon particles. With the enumeration procedures described, heterotrophic plate count bacteria were recovered at an average rate of 8.6 times higher than by conventional analyses. Over 17% of the samples contained carbon particles colonized with coliform bacteria as enumerated with modified most-probable-number and membrane filter techniques. In some instances coliform recoveries were 122 to 1,194 times higher than by standard procedures. Nearly 28% of the coliforms attached to these particles in drinking water exhibited the fecal biotype. Scanning electron micrographs of carbon fines from treated drinking water showed microcolonies of bacteria on particle surfaces. These data indicate that bacteria attached to carbon fines may be an important mechanism by which microorganisms penetrate treatment barriers and enter potable water supplies. PMID:3767356
Growth and persistence of pathogens on granular activated carbon filters.
Camper, A K; LeChevallier, M W; Broadaway, S C; McFeters, G A
1985-01-01
Three enteric pathogens Yersinia enterocolitica O:8, Salmonella typhimurium, and enterotoxigenic Escherichia coli, were examined for their ability to colonize granular activated carbon (GAC) in pure cultures and in the presence of autochthonous river water organisms. All three organisms readily colonized sterile GAC and maintained populations of ca. 10(5) to 10(7) CFU g-1 for 14 days when suspended in sterile river water. Exposure of pathogen biofilms on GAC to unsterile river water resulted in a gradual decline in pathogens on the carbon (0.08 to 0.14 log day-1). When pathogens were introduced to sterile GAC in the presence of heterotrophic plate count organisms, they attached at levels similar to those in the pure cultures and then decreased (0.10 to 0.22 log day-1). When added with heterotrophic plate count bacteria to GAC supporting a mature biofilm of native river water bacteria, they attached at a lower level (1.0 X 10(4) to 4.6 X 10(4) CFU g-1) and decreased at a more rapid rate (0.11 to 0.70 log day-1). PMID:3911903
Rodes, Laetitia; Paul, Arghya; Coussa-Charley, Michael; Al-Salami, Hani; Tomaro-Duchesneau, Catherine; Fakhoury, Marc; Prakash, Satya
2011-12-01
Retention time, which is analogous to transit time, is an index for bacterial stability in the intestine. Its consideration is of particular importance to optimize the delivery of probiotic bacteria in order to improve treatment efficacy. This study aims to investigate the effect of retention time on Lactobacilli and Bifidobacteria stability using an established in vitro human colon model. Three retention times were used: 72, 96, and 144 h. The effect of retention time on cell viability of different bacterial populations was analyzed with bacterial plate counts and PCR. The proportions of intestinal Bifidobacteria, Lactobacilli, Enterococci, Staphylococci and Clostridia populations, analyzed by plate counts, were found to be the same as that in human colonic microbiota. Retention time in the human colon affected the stability of Lactobacilli and Bifidobacteria communities, with maximum stability observed at 144 h. Therefore, retention time is an important parameter that influences bacterial stability in the colonic microbiota. Future clinical studies on probiotic bacteria formulations should take into consideration gastrointestinal transit parameters to improve treatment efficacy.
Tolerance of Chemoorganotrophic Bioleaching Microorganisms to Heavy Metal and Alkaline Stresses
Monballiu, Annick; Cardon, Nele; Tri Nguyen, Minh; Cornelly, Christel; Meesschaert, Boudewijn; Chiang, Yi Wai
2015-01-01
The bioleaching potential of the bacterium Bacillus mucilaginosus and the fungus Aspergillus niger towards industrial residues was investigated by assessing their response towards various heavy metals (including arsenic, cadmium, cobalt, chromium, nickel, lead, and zinc) and elevated pH. The plate diffusion method was performed for each metal to determine the toxicity effect. Liquid batch cultures were set up for more quantitative evaluation as well as for studying the influence of basicity. Growth curves were prepared using bacterial/fungal growth counting techniques such as plate counting, optical density measurement, and dry biomass determination. Cadmium, nickel, and arsenite had a negative influence on the growth of B. mucilaginosus, whereas A. niger was sensitive to cadmium and arsenate. However, it was shown that growth recovered when microorganisms cultured in the presence of these metals were inoculated onto metal-free medium. Based on the findings of the bacteriostatic/fungistatic effect of the metals and the adaptability of the microorganisms to fairly elevated pH values, it is concluded that both strains have potential applicability for further research concerning bioleaching of alkaline waste materials. PMID:26236176
NASA Technical Reports Server (NTRS)
Kimble, Randy A.; Pain, B.; Norton, T. J.; Haas, P.; Fisher, Richard R. (Technical Monitor)
2001-01-01
Silicon array readouts for microchannel plate intensifiers offer several attractive features. In this class of detector, the electron cloud output of the MCP intensifier is converted to visible light by a phosphor; that light is then fiber-optically coupled to the silicon array. In photon-counting mode, the resulting light splashes on the silicon array are recognized and centroided to fractional pixel accuracy by off-chip electronics. This process can result in very high (MCP-limited) spatial resolution for the readout while operating at a modest MCP gain (desirable for dynamic range and long term stability). The principal limitation of intensified CCD systems of this type is their severely limited local dynamic range, as accurate photon counting is achieved only if there are not overlapping event splashes within the frame time of the device. This problem can be ameliorated somewhat by processing events only in pre-selected windows of interest or by using an addressable charge injection device (CID) for the readout array. We are currently pursuing the development of an intriguing alternative readout concept based on using an event-driven CMOS Active Pixel Sensor. APS technology permits the incorporation of discriminator circuitry within each pixel. When coupled with suitable CMOS logic outside the array area, the discriminator circuitry can be used to trigger the readout of small sub-array windows only when and where an event splash has been detected, completely eliminating the local dynamic range problem, while achieving a high global count rate capability and maintaining high spatial resolution. We elaborate on this concept and present our progress toward implementing an event-driven APS readout.
Fluorometric determination of the DNA concentration in municipal drinking water.
McCoy, W F; Olson, B H
1985-01-01
DNA concentrations in municipal drinking water samples were measured by fluorometry, using Hoechst 33258 fluorochrome. The concentration, extraction, and detection methods used were adapted from existing techniques. The method is reproducible, fast, accurate, and simple. The amounts of DNA per cell for five different bacterial isolates obtained from drinking water samples were determined by measuring DNA concentration and total cell concentration (acridine orange epifluorescence direct cell counting) in stationary pure cultures. The relationship between DNA concentration and epifluorescence total direct cell concentration in 11 different drinking water samples was linear and positive; the amounts of DNA per cell in these samples did not differ significantly from the amounts in pure culture isolates. We found significant linear correlations between DNA concentration and colony-forming unit concentration, as well as between epifluorescence direct cell counts and colony-forming unit concentration. DNA concentration measurements of municipal drinking water samples appear to monitor changes in bacteriological quality at least as well as total heterotrophic plate counting and epifluorescence direct cell counting. PMID:3890737
del Río, Joaquín; Aguzzi, Jacopo; Costa, Corrado; Menesatti, Paolo; Sbragaglia, Valerio; Nogueras, Marc; Sarda, Francesc; Manuèl, Antoni
2013-10-30
Field measurements of the swimming activity rhythms of fishes are scant due to the difficulty of counting individuals at a high frequency over a long period of time. Cabled observatory video monitoring allows such a sampling at a high frequency over unlimited periods of time. Unfortunately, automation for the extraction of biological information (i.e., animals' visual counts per unit of time) is still a major bottleneck. In this study, we describe a new automated video-imaging protocol for the 24-h continuous counting of fishes in colorimetrically calibrated time-lapse photographic outputs, taken by a shallow water (20 m depth) cabled video-platform, the OBSEA. The spectral reflectance value for each patch was measured between 400 to 700 nm and then converted into standard RGB, used as a reference for all subsequent calibrations. All the images were acquired within a standardized Region Of Interest (ROI), represented by a 2 × 2 m methacrylate panel, endowed with a 9-colour calibration chart, and calibrated using the recently implemented "3D Thin-Plate Spline" warping approach in order to numerically define color by its coordinates in n-dimensional space. That operation was repeated on a subset of images, 500 images as a training set, manually selected since acquired under optimum visibility conditions. All images plus those for the training set were ordered together through Principal Component Analysis allowing the selection of 614 images (67.6%) out of 908 as a total corresponding to 18 days (at 30 min frequency). The Roberts operator (used in image processing and computer vision for edge detection) was used to highlights regions of high spatial colour gradient corresponding to fishes' bodies. Time series in manual and visual counts were compared together for efficiency evaluation. Periodogram and waveform analysis outputs provided very similar results, although quantified parameters in relation to the strength of respective rhythms were different. Results indicate that automation efficiency is limited by optimum visibility conditions. Data sets from manual counting present the larger day-night fluctuations in comparison to those derived from automation. This comparison indicates that the automation protocol subestimate fish numbers but it is anyway suitable for the study of community activity rhythms.
del Río, Joaquín; Aguzzi, Jacopo; Costa, Corrado; Menesatti, Paolo; Sbragaglia, Valerio; Nogueras, Marc; Sarda, Francesc; Manuèl, Antoni
2013-01-01
Field measurements of the swimming activity rhythms of fishes are scant due to the difficulty of counting individuals at a high frequency over a long period of time. Cabled observatory video monitoring allows such a sampling at a high frequency over unlimited periods of time. Unfortunately, automation for the extraction of biological information (i.e., animals' visual counts per unit of time) is still a major bottleneck. In this study, we describe a new automated video-imaging protocol for the 24-h continuous counting of fishes in colorimetrically calibrated time-lapse photographic outputs, taken by a shallow water (20 m depth) cabled video-platform, the OBSEA. The spectral reflectance value for each patch was measured between 400 to 700 nm and then converted into standard RGB, used as a reference for all subsequent calibrations. All the images were acquired within a standardized Region Of Interest (ROI), represented by a 2 × 2 m methacrylate panel, endowed with a 9-colour calibration chart, and calibrated using the recently implemented “3D Thin-Plate Spline” warping approach in order to numerically define color by its coordinates in n-dimensional space. That operation was repeated on a subset of images, 500 images as a training set, manually selected since acquired under optimum visibility conditions. All images plus those for the training set were ordered together through Principal Component Analysis allowing the selection of 614 images (67.6%) out of 908 as a total corresponding to 18 days (at 30 min frequency). The Roberts operator (used in image processing and computer vision for edge detection) was used to highlights regions of high spatial colour gradient corresponding to fishes' bodies. Time series in manual and visual counts were compared together for efficiency evaluation. Periodogram and waveform analysis outputs provided very similar results, although quantified parameters in relation to the strength of respective rhythms were different. Results indicate that automation efficiency is limited by optimum visibility conditions. Data sets from manual counting present the larger day-night fluctuations in comparison to those derived from automation. This comparison indicates that the automation protocol subestimate fish numbers but it is anyway suitable for the study of community activity rhythms. PMID:24177726
Highly charged ion secondary ion mass spectroscopy
Hamza, Alex V.; Schenkel, Thomas; Barnes, Alan V.; Schneider, Dieter H.
2001-01-01
A secondary ion mass spectrometer using slow, highly charged ions produced in an electron beam ion trap permits ultra-sensitive surface analysis and high spatial resolution simultaneously. The spectrometer comprises an ion source producing a primary ion beam of highly charged ions that are directed at a target surface, a mass analyzer, and a microchannel plate detector of secondary ions that are sputtered from the target surface after interaction with the primary beam. The unusually high secondary ion yield permits the use of coincidence counting, in which the secondary ion stops are detected in coincidence with a particular secondary ion. The association of specific molecular species can be correlated. The unique multiple secondary nature of the highly charged ion interaction enables this new analytical technique.
Jin, Mengtong; Sun, Wenshuo; Li, Qin; Sun, Xiaohong; Pan, Yingjie; Zhao, Yong
2014-04-04
We evaluated the difference of three standard curves in quantifying viable Vibrio parahaemolyticus in samples by real-time reverse-transcriptase PCR (Real-time RT-PCR). The standard curve A was established by 10-fold diluted cDNA. The cDNA was reverse transcripted after RNA synthesized in vitro. The standard curve B and C were established by 10-fold diluted cDNA. The cDNA was synthesized after RNA isolated from Vibrio parahaemolyticus in pure cultures (10(8) CFU/mL) and shrimp samples (10(6) CFU/g) (Standard curve A and C were proposed for the first time). Three standard curves were performed to quantitatively detect V. parahaemolyticus in six samples, respectively (Two pure cultured V. parahaemolyticus samples, two artificially contaminated cooked Litopenaeus vannamei samples and two artificially contaminated Litopenaeus vannamei samples). Then we evaluated the quantitative results of standard curve and the plate counting results and then analysed the differences. The three standard curves all show a strong linear relationship between the fractional cycle number and V. parahaemolyticus concentration (R2 > 0.99); The quantitative results of Real-time PCR were significantly (p < 0.05) lower than the results of plate counting. The relative errors compared with the results of plate counting ranked standard curve A (30.0%) > standard curve C (18.8%) > standard curve B (6.9%); The average differences between standard curve A and standard curve B and C were - 2.25 Lg CFU/mL and - 0.75 Lg CFU/mL, respectively, and the mean relative errors were 48.2% and 15.9%, respectively; The average difference between standard curve B and C was among (1.47 -1.53) Lg CFU/mL and the average relative errors were among 19.0% - 23.8%. Standard curve B could be applied to Real-time RT-PCR when quantify the number of viable microorganisms in samples.
Zhou, Baoqing; Chen, Bolu; Wu, Xin; Li, Fan; Yu, Pei; Aguilar, Zoraida P; Wei, Hua; Xu, Hengyi
2016-12-01
A rapid, reliable, and sensitive method for the detection of Cronobacter sakazakii, a common foodborne pathogen that may cause serious neonatal disease, has been developed. In this study, a rapid real-time quantitative PCR (qPCR) assay combined with sodium deoxycholate (SD) and propidium monoazide (PMA) was developed to detect C. sakazakii contamination in powdered infant formula (PIF). This method could eliminate the interference from dead or injured bacteria. Optimization studies indicated that SD and PMA at 0.08% (wt/vol) and 5µg/mL, respectively, were the most appropriate. In addition, qPCR, PMA-qPCR, SD-PMA-qPCR, and plate count assays were used to account for the number of viable bacteria in cell suspensions that were exposed to a 55°C water bath at different length of time. As a result, the viable number by PMA-qPCR showed significantly higher than of the number from SD-PMA-qPCR or plate counts. The number of viable bacteria was consistent between SD-PMA-qPCR and traditional plate counts, which indicated that SD treatment could eliminate the interference from dead or injured cells. Using the optimized parameters, the limit of detection with the SD-PMA-qPCR assay was 3.3×10 2 cfu/mL and 4.4×10 2 cfu/g in pure culture and in spiked PIF, respectively. A similar detection limit of 5.6×10 2 cfu/g was obtained in the presence of the Staphylococcus aureus (10 7 cfu/mL). The combined SD-PMA-qPCR assay holds promise for the rapid detection of viable C. sakazakii in PIF. Copyright © 2016 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
Villarreal, Martha Lissete Morales; Padilha, Marina; Vieira, Antonio Diogo Silva; Franco, Bernadette Dora Gombossy de Melo; Martinez, Rafael Chacon Ruiz; Saad, Susana Marta Isay
2013-01-01
Species-specific Quantitative Real Time PCR (qPCR) alone and combined with the use of propidium monoazide (PMA) were used along with the plate count method to evaluate the survival of the probiotic strains Lactobacillus acidophilus La-5 and Bifidobacterium animalis subsp. lactis Bb-12, and the bacteriocinogenic and potentially probiotic strain Lactobacillus sakei subsp. sakei 2a in synbiotic (F1) and probiotic (F2) petit-suisse cheeses exposed throughout shelf-life to in vitro simulated gastrointestinal tract conditions. The three strains studied showed a reduction in their viability after the 6 h assay. Bb-12 displayed the highest survival capacity, above 72.6 and 74.6% of the initial populations, respectively, by plate count and PMA-qPCR, maintaining population levels in the range or above 6 log CFU/g. The prebiotic mix of inulin and FOS did not offer any additional protection for the strains against the simulated gastrointestinal environment. The microorganisms' populations were comparable among the three methods at the initial time of the assay, confirming the presence of mainly viable and culturable cells. However, with the intensification of the stress induced throughout the various stages of the in vitro test, the differences among the methods increased. The qPCR was not a reliable enumeration method for the quantification of intact bacterial populations, mixed with large numbers of injured and dead bacteria, as confirmed by the scanning electron microscopy results. Furthermore, bacteria plate counts were much lower (P<0.05) than with the PMA-qPCR method, suggesting the accumulation of stressed or dead microorganisms unable to form colonies. The use of PMA overcame the qPCR inability to differentiate between dead and alive cells. The combination of PMA and species-specific qPCR in this study allowed a quick and unequivocal way of enumeration of viable closely related species incorporated into probiotic and synbiotic petit-suisse cheeses and under stress conditions. PMID:24358142
NASA Astrophysics Data System (ADS)
Thoren, K. M.; Sinigalliano, C. D.
2016-02-01
Despite numerous cases of beach bacteria affecting millions of people worldwide, the persistence of the bacteria populations in coastal areas is still not well understood. The purpose of this study was to test the levels of persistence of Fecal Indicating Bacteria (FIB) of enterococci, Escherichia coli, and Human-source Bacteroidales, within the intertidal "swash zone" and the deeper waist zone in which people commonly bathe and play. In addition, the study sought to determine if these bacterial contaminants may also be found in aerosols at the beach. Measuring solar insolation in relation to bacterial persistence in seaweed wrack was used to determine if sunlight plays a role in modifying concentrations of FIB at the beach. Light intensity measured by a solar photometer and air quality measured by aerosol plate counts and qPCR Microbial Source Tracking (MST) was compared to varying locations where the beach samples were collected. Results from water samples demonstrate that bacteria measured using plate counts and qPCR were indeed higher within the swash zone than in the waist zone. This is in contrast with the way that the EPA currently measures and determines the public safety of beach waters. They commonly measure the waist zone, but disregard the swash zone. Results from beach bio-aerosol samples showed a wide variety of fungi and bacteria in the beach air, and qPCR MST analysis of these bio-aerosols showed the presence of FIBs such as enterococci on several of the aerosol collection plates. This emphasizes the need to collect samples from the entire beach instead of just measuring at an isolated area, and that exposure to microbial contaminants may include bathing water, beach sand, seaweed wrack, and bio-aerosols. Thus, the data reveals a potential way to identify harmful levels of bacteria and dangerous levels of poor air quality at recreational beaches. These results expound the need for broader assessment of potential beach contamination, not only the swimming water, but also the beach air, shoreline, and also varying depths of water, which can be extremely beneficial to reduce people's risk from microbial contamination exposure.
Nishimura, Hidekazu
2012-11-01
Several Japanese companies sell electrical devices advertised as effective in inactivating viruses and killing bacteria by releasing special materials, e.g., Plasmacluster ions, Nanoe particle and minus ions, into the air. These companies claim that their devices killed bacteria on plates in their own experiments. We tested device effectiveness using the same experiments from the Plasmacluster ioniser SHARP Co., Japan, the Nanoe generator Panasonic Co., Japan, and the Vion KING JIM Co., Japan, to test their advertising claims. Bactericidal ability on agar plate was tested, using Staphylococcus aureus, Pseudomonas aeruginosa, Bacillus cereus, and Enterococcus faecalis as follows: the medium containing a certain amount of each bacterium was put onto an agar plate and smeared. Plates were kept in a closed chamber (inner volume 14.4 m3) or a glove box (inner volume 0.2 m), with one of the devices run for 2 hours. Plates not exposed to any device were used as controls. Each plate was retrieved and put in an incubator to count the number of bacterial colonies formed on the plate. There was no significant difference in the number of colonies on plates exposed to devices compared to control, in the number for all devices, or in all bacteria tested in experiments in the 14.4 m3 chamber. These results strongly suggest that these devices have almost no bactericidal effect, at least in space exceeding this volume. Colony formation was suppressed in the glove box in all devices and in all bacteria tested except P. aeruginosa, although the degree of suppression differed among experiments. The colony formation suppression mechanism was analyzed, and indicated that:colony formation did not change even after the removal of Plasmacluster ions, Nanoe particles, or negative ions from the air, while colony formation was decreased drastically by the removal of ozone from space, which was revealed to be generated inevitably during device operation. These results strongly suggest that the bactericidal effect seen only on the agar plate in narrow space was explained by ozone released in space as a by-product, not by special materials as advertising claimed. It is thus important to analyze the effect of special materials such as those done in this study and to suggest the involvement of ozone as the true cause, as have been done in this study, in evaluating bactericidal effect or viral inactivation as advertised by these companies.
In situ evaluation of a new silorane-based composite resin's bioadhesion properties.
Claro-Pereira, Diogo; Sampaio-Maia, Benedita; Ferreira, Carla; Rodrigues, Andreia; Melo, Luís F; Vasconcelos, Mário R
2011-12-01
The aim of the present study was to compare, in situ, the initial dental plaque formation on a recently developed silorane-based composite resin, Filtek Silorane, and on a widely used methacrylate-based composite resin, Synergy D6, and to relate possible differences to surface free energy, hydrophobicity and type of organic matrix. Discs of Filtek Silorane and Synergy D6 were prepared and polished equally in order to attain the same surface roughness. Water, formamide and 1-bromonaphthalene contact angles were determined and the surface free energy and the hydrophobicity of the materials calculated. Two discs of each material were mounted in individual oral splints and exposed to the oral cavity of 20 participants for 4h. After this period the microbial adhesion to both materials' surface was measured by two different approaches, the DAPI staining and the plate count. Statistical analysis was performed using non-parametric tests. The surface roughness (R(a) parameter) was similar between the two materials and lower than 0.2μm. Mean water and formamide contact angles were significantly higher for Filtek Silorane, which presented significantly lower surface free energy and greater degree of hydrophobicity in comparison to Synergy D6. The bioadhesion potential evaluated by either DAPI staining or plate count did not differ between the two materials. In contrast to previous in vitro studies, the present in situ study found no statistically significant differences with respect to bacterial adhesion between Filtek Silorane and Synergy D6, despite the differences found for surface free energy and hydrophobicity. Copyright © 2011 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.
Gómez-Aldapa, Carlos A; Rangel-Vargas, Esmeralda; Torres-Vitela, Ma Refugio; Villarruel-López, Angélica; Acevedo-Sandoval, Otilio A; Gordillo-Martínez, Alberto J; Godínez-Oviedo, Angélica; Castro-Rosas, Javier
2018-02-01
Leafy greens have been associated with foodborne disease outbreaks in different countries. To decrease microbial contamination of leafy greens, chemical agents are commonly used; however, a number of studies have shown these agents to have limited antimicrobial effect against pathogenic bacteria on vegetables. The objective of this study was to compare the antibacterial effect of Hibiscus sabdariffa calyx extracts (water, methanol, acetone, and ethyl acetate), sodium hypochlorite, acetic acid, and colloidal silver against foodborne bacteria on leafy greens. Thirteen foodborne bacteria were used in the study: Listeria monocytogenes, Shigella flexneri, Salmonella serotypes Typhimurium Typhi, and Montevideo, Staphylococcus aureus, Escherichia coli O157:H7, five E. coli pathotypes (Shiga toxin-producing, enteropathogenic, enterotoxigenic, enteroinvasive, and enteroaggregative), and Vibrio cholerae O1. Each foodborne bacterium was separately inoculated on romaine lettuce, spinach, and coriander leaves. Separately, contaminated leafy greens were immersed in four hibiscus extracts and in sanitizers for 5 min. Next, green leaves were washed with sterile tap water. Separately, each green leaf was placed in a bag that contained 0.1% sterile peptone water and was rubbed for 2 min. Counts were done by plate count using appropriate dilutions (in sterile peptone water) of the bacterial suspensions spread on Trypticase soy agar plates and incubated at 35 ± 2°C for 48 h. Statistically significant differences ( P < 0.05) were calculated with an analysis of variance and Duncan's test. All 13 foodborne bacteria attached to leafy greens. Roselle calyx extracts caused a significantly greater reduction ( P < 0.05) in concentration of all foodborne bacteria on contaminated romaine lettuce, spinach, and coriander than did the sodium hypochlorite, colloidal silver, and acetic acid. Dry roselle calyx extracts may potentially be a useful addition to disinfection procedures for romaine lettuce, spinach, and coriander.
Intercondylar humerus fracture- parallel plating and its results.
Kumar, Sanjiv; Singh, Sudhir; Kumar, Dharmender; Kumar, Neeraj; Verma, Reetu
2015-01-01
Intercondylar fracture of humerus is one of the commonest fractures of young adult and counts for about 30% of all elbow fractures. The treatment of these fractures continues to present challenges despite advances in internal fixation. Although orthogonal plating use to provid adequate functional results in these fractures, parallel plating is said to be mechanically more stable construct thus allowing early mobilization and better range of motion. AIM of the study is to assess the clinical as well functional results of these fractures treated with parallel plating. Prospective study in a tertiary care hospital. A total of 23 fresh patients of intercondylar fracture of humerus from Jan 2013 to May 2014 were included in the study and were treated with parallel plating. These patients were followed at 3, 6, 12, 24 weeks and at 1year of follow up and assessed in terms of time for union, range of motion, MAYO score, DASH score and complication rate. At final follow up Mayo score was 96.32±04.96 from 5.00±01.26 and DASH SCORE was 31.42±2.04 which dropped from 150±05.34, Range of motion improved from 21.38±05.70 to 116.1±07.92 with 100% union rate and complications less than 19%. Parallel plating for intercondylar fracture of humerus is excellent method of fixation and results are similar to those treated with orthogonal plating.
Free Surface Effects on the Wake of a Flat Plate.
1984-11-08
D-i46 98 FREE SURFCE’EFFECTS ON THE MAKE OF A FLAT PLTE(U) i/l 9(8 NAVAL RESEARCH LAB WASHINGTON DC T F SWEAN ET AL. 08 NOV 84 NRL-MR...5426UNCLASSIFIED F/ 20/4 NL 11111 ~ L.0 2 4 11111L .563 I -A 16 CEO -- . . IV NRL Memorandum Rpot52 Free Surface iEffwcs on the Wake of Al lit Plate T . F. SWEAlJ...13b. TIME COVERED 14. DATE OF REPORT (YeasrUonitDay) S.PAGE COUNT .0 - Interim IFROM _ TO T 1984 November 8 FS23 16 SUPPLEMENTARY NOTATION 17 COSATI
NASA Technical Reports Server (NTRS)
Lampton, M.; Malina, R. F.
1976-01-01
A position-sensitive event-counting electronic readout system for microchannel plates (MCPs) is described that offers the advantages of high spatial resolution and fast time resolution. The technique relies upon a four-quadrant electron-collecting anode located behind the output face of the microchannel plate, so that the electron cloud from each detected event is partly intercepted by each of the four quadrants. The relative amounts of charge collected by each quadrant depend on event position, permitting each event to be localized with two ratio circuits. A prototype quadrant anode system for ion, electron, and extreme ultraviolet imaging is described. The spatial resolution achieved, about 10 microns, allows individual MCP channels to be distinguished.
Muhlisin; Panjono; Kim, Dong Soo; Song, Yeong Rae; Lee, Sung-Jin; Lee, Jeong Koo; Lee, Sung Ki
2014-01-01
This study was conducted to observe the effects of gas composition in modified atmosphere packaging (MAP) on the shelf-life of Longissimus dorsi of Korean Native Black Pigs-Duroc Crossbred (KNP×D) during refrigerated storage. Muscle sample was obtained from the left side of carcass of seven months old of KNP×D barrow. The sample was sliced into 1 cm in thickness, placed on trays (two slices/tray) and filled with different gas composition, i.e. 0:20:80/O2:CO2:N2 (MAP1), 30:20:50/O2:CO2:N2 (MAP2) and 70:20:10/O2:CO2:N2 (MAP3). Other slices of sample were vacuum packed (VP) as a control. All packs were stored at 5±1°C. At 12 d of storage, pH value of MAP2 and MAP3 were higher (p<0.05) than that of MAP1 and pH value of MAP1 was higher (p<0.05) than that of VP. At 6 d of storage, redness (a*) value of MAP2 and MAP3 were higher (p<0.05) than that of VP and MAP1 and, at 9 and 12 d of storage, redness value of MAP3 was higher (p<0.05) than that of VP, MAP1, and MAP2. At 3, 6, 9, and 12 d of storage, the 2-thiobarbituric acid reactive substances (TBARS) value of MAP3 was higher than that of MAP2 and TBARS value of MAP2 was higher than that of VP and MAP1. At 3, 6, 9, and 12 d of storage, volatile basic nitrogen values of MAP2 and MAP3 were higher (p<0.05) than those of VP and MAP1. At 3 d of storage, total aerobic plate counts of MAP2 and MAP3 were higher (p<0.05) than those of VP and MAP1 and, at 6 d of storage, total aerobic plate counts of MAP3 was higher (p<0.05) than that of MAP1 and MAP2. However, there was no significant different total aerobic plate count among MAP1, MAP2, and MAP3 at 9 and 12 d of storage. There was no significant different total anaerobic plate count among MAP1, MAP2, and MAP3 during storage. It is concluded that the MAP containing 30:20:50/O2:CO2:N2 gas composition (MAP2) might be ideal for better meat quality for KNP×D meat. PMID:25083110
[Surgical approach of internal fixation of maxillofacial fracture].
Liu, Dashun; Zhang, Ruizhen; Dong, Xiao
2013-11-01
By summary and analysis of rigid internal fixation for the treatment of maxillofacial fractures incision and exposure, investigate the plate reasonable surgical approach of fracture reduction and fixation titanium. Summary of the 76 surgical cases, Counting the statistics of the number that the surgery ways choose by facial incision and fractures location, analysis of the indications for surgery and the advantages and disadvantages of various surgical approaches. Followed up for more than six months, in order to observe the recovery of occlusal function and the facial cosmetic results. The upper jaw or cheek bone has the more possibility in facial fracture, which used of a small incision hidden under the lip gingival sulcus and lower eyelid. After six months, the facial wound healing recover in good occlusal with no obvious scarring. Reasonable choice of surgical incision can make the fracture site exposure and the facial aesthetic effect into account.
Characterization of Al-Cu-Mg-Ag Alloy RX226-T8 Plate
NASA Technical Reports Server (NTRS)
Lach, Cynthia L.; Domack, Marcia S.
2003-01-01
Aluminum-copper-magnesium-silver (Al-Cu-Mg-Ag) alloys that were developed for thermal stability also offer attractive ambient temperature strength-toughness combinations, and therefore, can be considered for a broad range of airframe structural applications. The current study evaluated Al-Cu-Mg-Ag alloy RX226-T8 in plate gages and compared performance with sheet gage alloys of similar composition. Uniaxial tensile properties, plane strain initiation fracture toughness, and plane stress tearing resistance of RX226-T8 were examined at ambient temperature as a function of orientation and thickness location in the plate. Properties were measured near the surface and at the mid-plane of the plate. Tensile strengths were essentially isotropic, with variations in yield and ultimate tensile strengths of less than 2% as a function of orientation and through-thickness location. However, ductility varied by more than 15% with orientation. Fracture toughness was generally higher at the mid-plane and greater for the L-T orientation, although the differences were small near the surface of the plate. Metallurgical analysis indicated that the microstructure was primarily recrystallized with weak texture and was uniform through the plate with the exception of a fine-grained layer near the surface of the plate. Scanning electron microscope analysis revealed Al-Cu-Mg second phase particles which varied in composition and were primarily located on grain boundaries parallel to the rolling direction. Fractography of toughness specimens for both plate locations and orientations revealed that fracture occurred predominantly by transgranular microvoid coalescence. Introduction High-strength, low-density Al-Cu-Mg-Ag alloys were initially developed to replace conventional 2000 (Al-Cu-Mg) and 7000 (Al-Zn-Cu-Mg) series aluminum alloys for aircraft structural applications [1]. During the High Speed Civil Transport (HSCT) program, improvements in thermal stability were demonstrated for candidate aircraft wing and fuselage skin materials through the addition of silver to Al-Cu-Mg alloys based on Al 2519 chemistry [2]. Thermal stability of the resulting Al-Cu-Mg-Ag alloys, C415-T8 and C416-T8, was due to co-precipitation of the thermally stable . (AlCu) and ' (Al2Cu) strengthening phases [1-4]. The strength and toughness behavior was investigated for these alloys produced as 0.090-inch thick rolled sheet in the T8 condition and after various thermal exposures. The mechanical properties were shown to be competitive with conventional aircraft alloys, 2519-T8 and 2618-T8 [2]. During the Integral Airframe Structure (IAS) program, advanced aluminum alloys were examined for use in an integrally stiffened airframe structure where the skin and stiffeners would be machined from plate and extruded frames would be mechanically attached (see Figure 1) [5]. Advantages of integrally stiffened structure include reduced part count, and reduced assembly times compared to conventional built-up airframe structure. The near-surface properties of a thick plate are of significance for a machined integrally stiffened airframe structure since this represents the skin location. Properties measured at the mid-plane of the plate are more representative of the stiffener web. RX226 was developed to exploit strength-toughness improvements and thermal stability benefits of Al-Cu-Mg-Ag alloys in plate gages. This study evaluated the microstructure and properties of three gages of plate produced in the T8 condition.
Hamling, A E; Jenschke, B E; Calkins, C R
2008-04-01
The objective of this study was to determine the retail shelf stability of beef chuck and round muscles enhanced with ammonium hydroxide, salt, and carbon monoxide. A split plot design was used for each of 3 muscles [triceps brachii (TB), biceps femoris (BF), and rectus femoris (RF)] with 2 treatments (0 and 20% pump), 3 dark storage periods (1, 2, and 3 wk), and 3 replications in the whole plot and retail display period as the split plot. There were a total of 12 subprimals per treatment per dark storage period (n = 72 each). Individual steaks were cut to a thickness of 2.54 cm and packaged in a modified-atmosphere package (MAP). The TB was packaged in a high-oxygen MAP (80% oxygen, 20% carbon dioxide). The BF and RF were packaged in a low-oxygen MAP (100% carbon dioxide). At the completion of each dark storage period, steaks were subjected to 7 d of simulated retail display. Steaks were used for objective and subjective color measurements, total plate counts, and determination of retail purge and oxidation. For all muscles, total plate counts were always numerically greater in injected steaks. Triceps brachii steaks held in dark storage for 3 wk and displayed at retail for 4 or more days all exceeded 10(7) log of cfu/cm(2) for aerobic plate count. Biceps femoris and RF steaks packaged in a low-oxygen MAP had much lower bacterial counts, with levels below 4.2 log of cfu/cm(2), even after 7 d of retail display. Oxidation values for the TB were extremely high (ranging from 12.3 to 26.6), whereas the BF and RF had values that were much lower (< or =1.0 mg of malonaldehyde/kg of muscle), likely due to the oxidation occurring in a high-oxygen MAP for the TB. Enhanced TB steaks proved to have greater color stability (less discoloration) than nonenhanced TB steaks. In addition, the BF and RF (low-oxygen MAP) steaks had better color stability (more stable redness values) than TB (high-oxygen MAP) steaks, although TB steaks initially exhibited a brighter red color. Retail display life was enhanced by packaging in 100% carbon dioxide, and enhanced steaks exhibited greater color stability in retail display than control steaks.
Shen, Feng; Du, Wenbin; Kreutz, Jason E; Fok, Alice; Ismagilov, Rustem F
2010-10-21
This paper describes a SlipChip to perform digital PCR in a very simple and inexpensive format. The fluidic path for introducing the sample combined with the PCR mixture was formed using elongated wells in the two plates of the SlipChip designed to overlap during sample loading. This fluidic path was broken up by simple slipping of the two plates that removed the overlap among wells and brought each well in contact with a reservoir preloaded with oil to generate 1280 reaction compartments (2.6 nL each) simultaneously. After thermal cycling, end-point fluorescence intensity was used to detect the presence of nucleic acid. Digital PCR on the SlipChip was tested quantitatively by using Staphylococcus aureus genomic DNA. As the concentration of the template DNA in the reaction mixture was diluted, the fraction of positive wells decreased as expected from the statistical analysis. No cross-contamination was observed during the experiments. At the extremes of the dynamic range of digital PCR the standard confidence interval determined using a normal approximation of the binomial distribution is not satisfactory. Therefore, statistical analysis based on the score method was used to establish these confidence intervals. The SlipChip provides a simple strategy to count nucleic acids by using PCR. It may find applications in research applications such as single cell analysis, prenatal diagnostics, and point-of-care diagnostics. SlipChip would become valuable for diagnostics, including applications in resource-limited areas after integration with isothermal nucleic acid amplification technologies and visual readout.
7 CFR 58.648 - Microbiological requirements for ice cream.
Code of Federal Regulations, 2012 CFR
2012-01-01
... requirements for ice cream. The finished product shall contain not more than 50,000 bacteria per gram as determined by the standard plate count, and shall contain not more than 10 coliform organisms per gram for plain and not more than 20 coliform per gram in chocolate, fruit, nut or other flavors in three out of...
7 CFR 58.648 - Microbiological requirements for ice cream.
Code of Federal Regulations, 2013 CFR
2013-01-01
... requirements for ice cream. The finished product shall contain not more than 50,000 bacteria per gram as determined by the standard plate count, and shall contain not more than 10 coliform organisms per gram for plain and not more than 20 coliform per gram in chocolate, fruit, nut or other flavors in three out of...
7 CFR 58.648 - Microbiological requirements for ice cream.
Code of Federal Regulations, 2011 CFR
2011-01-01
... requirements for ice cream. The finished product shall contain not more than 50,000 bacteria per gram as determined by the standard plate count, and shall contain not more than 10 coliform organisms per gram for plain and not more than 20 coliform per gram in chocolate, fruit, nut or other flavors in three out of...
7 CFR 58.648 - Microbiological requirements for ice cream.
Code of Federal Regulations, 2014 CFR
2014-01-01
... requirements for ice cream. The finished product shall contain not more than 50,000 bacteria per gram as determined by the standard plate count, and shall contain not more than 10 coliform organisms per gram for plain and not more than 20 coliform per gram in chocolate, fruit, nut or other flavors in three out of...
7 CFR 58.648 - Microbiological requirements for ice cream.
Code of Federal Regulations, 2010 CFR
2010-01-01
... requirements for ice cream. The finished product shall contain not more than 50,000 bacteria per gram as determined by the standard plate count, and shall contain not more than 10 coliform organisms per gram for plain and not more than 20 coliform per gram in chocolate, fruit, nut or other flavors in three out of...
Gamble, Rachel; Muriana, Peter M.
2007-01-01
Listeria monocytogenes is a significant food-borne pathogen that is capable of adhering to and producing biofilms on processing equipment, making it difficult to eliminate from meat-processing environments and allowing potential contamination of ready-to-eat (RTE) products. We devised a fluorescence-based microplate method for screening isolates of L. monocytogenes for the ability to adhere to abiotic surfaces. Strains of L. monocytogenes were incubated for 2 days at 30°C in 96-well microplates, and the plates were washed in a plate washer. The retained cells were incubated for 15 min at 25°C with 5,6-carboxyfluorescein diacetate and washed again, and then the fluorescence was read with a plate reader. Several enzymatic treatments (protease, lipase, and cellulase) were effective in releasing adherent cells from the microplates, and this process was used for quantitation on microbiological media. Strongly adherent strains of L. monocytogenes were identified that had 15,000-fold-higher levels of fluorescence and 100,000-fold-higher plate counts in attachment assays than weakly adherent strains. Strongly adherent strains of L. monocytogenes adhered equally well to four different substrates (glass, plastic, rubber, and stainless steel); showed high-level attachment on microplates at 10, 20, 30, and 40°C; and showed significant differences from weakly adherent strains when examined by scanning electron microscopy. A greater incidence of strong adherence was observed for strains isolated from RTE meats than for those isolated from environmental surfaces. Analysis of surface adherence among Listeria isolates from processing environments may provide a better understanding of the molecular mechanisms involved in attachment and suggest solutions to eliminate them from food-processing environments. PMID:17586676
Perrenoud, Alexandre Grand-Guillaume; Farrell, William P; Aurigemma, Christine M; Aurigemma, Nicole C; Fekete, Szabolcs; Guillarme, Davy
2014-09-19
Superficially porous particles (SPP), or core shell particles, which consist of a non-porous silica core surrounded by a thin shell of porous silica, have gained popularity as a solid support for chromatography over the last decade. In the present study, five unbonded silica, one diol, and two ethylpyridine (2-ethyl and 4-ethyl) SPP columns were evaluated under SFC conditions using two mixtures, one with 17 drug-like compounds and the other one with 7 drug-like basic compounds. Three of the SPP phases, SunShell™ 2-ethylpyridine (2-EP), Poroshell™ HILIC, and Ascentis(®) Express HILIC, exhibited superior performances relative to the others (reduced theoretical plate height (hmin) values of 1.9-2.5 for neutral compounds). When accounting for both achievable plate count and permeability of the support using kinetic plot evaluation, the Cortecs™ HILIC 1.6μm and Ascentis(®) Express HILIC 2.7μm phases were found to be the best choices among tested SPPs to reach efficiencies up to 30,000 plates in the minimum amount of time. For desired efficiencies ranging from 30,000 to 60,000 plates, the SunShell™ 2-EP 2.6μm column clearly outperformed all other SPPs. With the addition of a mobile phase additive such as 10mM ammonium formate, which was required to elute the basic components with sharp peaks, the Poroshell™ HILIC, SunShell™ Diol and SunShell™ 2-EP phases represent the most orthogonal SPP columns with the highest peak capacities. This study demonstrates the obvious benefits of using columns packed with SPP on current SFC instrumentation. Copyright © 2014 Elsevier B.V. All rights reserved.
Rock, Clare; Harris, Anthony D; Reich, Nicholas G; Johnson, J Kristie; Thom, Kerri A
2013-11-01
Hand hygiene (HH) is recognized as a basic effective measure in prevention of nosocomial infections. However, the importance of HH before donning nonsterile gloves is unknown, and few published studies address this issue. Despite the lack of evidence, the World Health Organization and other leading bodies recommend this practice. The aim of this study was to assess the utility of HH before donning nonsterile gloves prior to patient contact. A prospective, randomized, controlled trial of health care workers entering Contact Isolation rooms in intensive care units was performed. Baseline finger and palm prints were made from dominant hands onto agar plates. Health care workers were then randomized to directly don nonsterile gloves or perform HH and then don nonsterile gloves. Postgloving finger and palm prints were then made from the gloved hands. Plates were incubated and colony-forming units (CFU) of bacteria were counted. Total bacterial colony counts of gloved hands did not differ between the 2 groups (6.9 vs 8.1 CFU, respectively, P = .52). Staphylococcus aureus was identified from gloves (once in "hand hygiene prior to gloving" group, twice in "direct gloving" group). All other organisms were expected commensal flora. HH before donning nonsterile gloves does not decrease already low bacterial counts on gloves. The utility of HH before donning nonsterile gloves may be unnecessary. Copyright © 2013 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Mosby, Inc. All rights reserved.
Addo, K K; Mensah, G I; Aning, K G; Nartey, N; Nipah, G K; Bonsu, C; Akyeh, M L; Smits, H L
2011-02-01
To investigate the microbiological quality and the presence of antibiotic residues in raw cow milk and in some indigenous milk products produced and marketed by the informal sector in the coastal savannah zone of Ghana. Milk samples were aseptically collected from 224 kraals and samples of 26 indigenous milk products were purchased from processors and retailers. Total plate counts, total coliform counts and the presence of Escherichia coli and E. coli O157:H7 were determined in all 250 samples. Milk samples were also tested for antibiotic residues. Total plate counts exceeded 10⁵ CFU/ml in 45.2% of the samples while coliforms exceeded 10³ CFU/ml in 66.0% and E. coli was detected in 11.2%. E. coli was present in raw cow milk but not in the indigenous products and all E. coli isolates were negative for E. coli O157:H7. Antibiotic residues were detected in 3.1% of the raw cow milk samples. Bulk milk contains unacceptable levels of hygiene indicators and antibiotic residues and is a potential source of milk-borne infections. The detection of E. coli and antibiotic residues raises public health concerns about the safety of fresh unpasteurized cow milk in the coastal savannah zone of Ghana and calls for improved farm hygiene, the need for milk pasteurization and the sensible use of antibiotics in the milk industry. © 2010 Blackwell Publishing Ltd.
The use of detergents and sanitizers in dairy farm sanitation--an updated perspective.
Gilbert, P H
1982-06-01
Raw milk quality in South Africa is poor and standard plate counts in the millions per ml are common. This is largely due to inefficient cleaning and sanitizing of dairy equipment. The basic constituents in milk are described and various soils are classified as soluble in water, alkali, acid, solvent or surfactant or as insoluble. The importance of water quality is highlighted and the influence of mineral salts on soil deposition described. Dairy detergents are broadly classified as alkaline or acid, the former being most effective against fatty and proteinaceous soils and the latter effective against mineral salts. Typical detergent ingredients and their properties are described. Chlorine is incorporated into alkaline detergents not as a sanitizing agent, but as a peptizing agent to aid in protein soil removal. At high pH values the antimicrobial activity of chlorine is greatly diminished. The use of a daily acidified rinse (pH 3,0-5,0) is preferred to the periodic acid wash, since the acid rinse prevents mineral deposition rather than removing accumulated milkstone. All cleaning programmes follow the same fundamental steps--Pre-rinse (40-50 degrees C), wash (60-70 degrees C), rinse (pH 3,0-5,0) and sanitize (25 ppm iodine and 100 ppm chlorine). Farms following such a programme are able to achieve Standard Plate Counts of less than 10,000/ml and coliform counts of less than 10/ml for raw milk.
Martin, F Elizabeth; Nadkarni, Mangala A; Jacques, Nicholas A; Hunter, Neil
2002-05-01
The bacteria found in carious dentine were correlated with the tissue response of the dental pulps of 65 teeth extracted from patients with advanced caries and pulpitis. Standardized homogenates of carious dentine were plated onto selective and nonselective media under anaerobic and microaerophilic conditions. In addition, real-time PCR was used to quantify the recovery of anaerobic bacteria. Primers and fluorogenic probes were designed to detect the total anaerobic microbial load, the genera Prevotella and Fusobacterium, and the species Prevotella melaninogenica, Porphyromonas endodontalis, Porphyromonas gingivalis, and Micromonas (formerly Peptostreptococcus) micros. The pulpal pathology was categorized according to the cellular response and degenerative changes. Analysis of cultured bacteria showed a predominance of gram-positive microorganisms, particularly lactobacilli. Gram-negative bacteria were also present in significant numbers with Prevotella spp., the most numerous anaerobic group cultured. Real-time PCR analysis indicated a greater microbial load than that determined by colony counting. The total number of anaerobes detected was 41-fold greater by real-time PCR than by colony counting, while the numbers of Prevotella and Fusobacterium spp. detected were 82- and 2.4-fold greater by real-time PCR than by colony counting, respectively. Real-time PCR also identified M. micros, P. endodontalis, and P. gingivalis in 71, 60, and 52% of carious samples, respectively. Correlation matrices of the real-time PCR data revealed significant positive associations between M. micros and P. endodontalis detection and inflammatory degeneration of pulpal tissues. These anaerobes have been strongly implicated in endodontic infections that occur as sequelae to carious pulpitis. Accordingly, the data suggest that the presence of high levels of these bacteria in carious lesions may be indicative of irreversible pulpal pathology.
Berrang, M E; Dickens, J A; Musgrove, M T
2000-11-01
Scalding has been found to lower the levels of Campylobacter on broiler carcasses. However, the numbers recovered from whole-carcass rinse samples increase following defeathering. This study was undertaken to examine the effect of a second scald applied after defeathering on microbial levels recovered from carcass rinses. Four treatments were evaluated: 1) immersion at 60 C for 28 s 30 min after defeathering, 2) immersion at 60 C for 28 s immediately after defeathering, 3) spray at 73 C for 20 s 30 min after defeathering, and 4) spray at 71 C for 20 s immediately after defeathering. As reported earlier, a significant increase in Campylobacter counts per mL whole carcass rinse was noted after carcasses were defeathered. However, when applied 30 min after defeathering, neither the immersion nor the spray second scald treatments lowered the Campylobacter counts. Likewise, neither treatment had any affect on Escherichia coli or coliform bacteria counts, even though total counts were slightly reduced by the treatments. When the second scald treatment immediately followed defeathering, the same trends were observed. Campylobacter counts after the second scald remained at the postpick levels, as did counts for E. coli and coliform bacteria, but total plate counts were slightly reduced. Overall, it would appear that a postscald treatment gentle enough not to alter the carcass appearance or meat quality would not effectively lower Campylobacter, E. coli, or coliform bacteria counts.
Skazalski, C; Whiteley, R; Hansen, C; Bahr, R
2018-05-01
Use of a commercially available wearable device to monitor jump load with elite volleyball players has become common practice. The purpose of this study was to evaluate the validity and reliability of this device, the Vert, to count jumps and measure jump height with professional volleyball players. Jump count accuracy was determined by comparing jumps recorded by the device to jumps observed through systematic video analysis of three practice sessions and two league matches performed by a men's professional volleyball team. Jumps performed by 14 players were each coded for time and jump type and individually matched to device recorded jumps. Jump height validity of the device was examined against reference standards as participants performed countermovement jumps on a force plate and volleyball-specific jumps with a Vertec. The Vert device accurately counted 99.3% of the 3637 jumps performed during practice and match play. The device showed excellent jump height interdevice reliability for two devices placed in the same pouch during volleyball jumps (r = .99, 95% CI 0.98-0.99). The device had a minimum detectable change (MDC) of 9.7 cm and overestimated jump height by an average of 5.5 cm (95% CI 4.5-6.5) across all volleyball jumps. The Vert device demonstrates excellent accuracy counting volleyball-specific jumps during training and competition. While the device is not recommended to measure maximal jumping ability when precision is needed, it provides an acceptable measure of on-court jump height that can be used to monitor athlete jump load. © 2018 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
A high-throughput, multi-channel photon-counting detector with picosecond timing
NASA Astrophysics Data System (ADS)
Lapington, J. S.; Fraser, G. W.; Miller, G. M.; Ashton, T. J. R.; Jarron, P.; Despeisse, M.; Powolny, F.; Howorth, J.; Milnes, J.
2009-06-01
High-throughput photon counting with high time resolution is a niche application area where vacuum tubes can still outperform solid-state devices. Applications in the life sciences utilizing time-resolved spectroscopies, particularly in the growing field of proteomics, will benefit greatly from performance enhancements in event timing and detector throughput. The HiContent project is a collaboration between the University of Leicester Space Research Centre, the Microelectronics Group at CERN, Photek Ltd., and end-users at the Gray Cancer Institute and the University of Manchester. The goal is to develop a detector system specifically designed for optical proteomics, capable of high content (multi-parametric) analysis at high throughput. The HiContent detector system is being developed to exploit this niche market. It combines multi-channel, high time resolution photon counting in a single miniaturized detector system with integrated electronics. The combination of enabling technologies; small pore microchannel plate devices with very high time resolution, and high-speed multi-channel ASIC electronics developed for the LHC at CERN, provides the necessary building blocks for a high-throughput detector system with up to 1024 parallel counting channels and 20 ps time resolution. We describe the detector and electronic design, discuss the current status of the HiContent project and present the results from a 64-channel prototype system. In the absence of an operational detector, we present measurements of the electronics performance using a pulse generator to simulate detector events. Event timing results from the NINO high-speed front-end ASIC captured using a fast digital oscilloscope are compared with data taken with the proposed electronic configuration which uses the multi-channel HPTDC timing ASIC.
High throughput RNAi assay optimization using adherent cell cytometry.
Nabzdyk, Christoph S; Chun, Maggie; Pradhan, Leena; Logerfo, Frank W
2011-04-25
siRNA technology is a promising tool for gene therapy of vascular disease. Due to the multitude of reagents and cell types, RNAi experiment optimization can be time-consuming. In this study adherent cell cytometry was used to rapidly optimize siRNA transfection in human aortic vascular smooth muscle cells (AoSMC). AoSMC were seeded at a density of 3000-8000 cells/well of a 96 well plate. 24 hours later AoSMC were transfected with either non-targeting unlabeled siRNA (50 nM), or non-targeting labeled siRNA, siGLO Red (5 or 50 nM) using no transfection reagent, HiPerfect or Lipofectamine RNAiMax. For counting cells, Hoechst nuclei stain or Cell Tracker green were used. For data analysis an adherent cell cytometer, Celigo® was used. Data was normalized to the transfection reagent alone group and expressed as red pixel count/cell. After 24 hours, none of the transfection conditions led to cell loss. Red fluorescence counts were normalized to the AoSMC count. RNAiMax was more potent compared to HiPerfect or no transfection reagent at 5 nM siGLO Red (4.12 +/-1.04 vs. 0.70 +/-0.26 vs. 0.15 +/-0.13 red pixel/cell) and 50 nM siGLO Red (6.49 +/-1.81 vs. 2.52 +/-0.67 vs. 0.34 +/-0.19). Fluorescence expression results supported gene knockdown achieved by using MARCKS targeting siRNA in AoSMCs. This study underscores that RNAi delivery depends heavily on the choice of delivery method. Adherent cell cytometry can be used as a high throughput-screening tool for the optimization of RNAi assays. This technology can accelerate in vitro cell assays and thus save costs.
High throughput RNAi assay optimization using adherent cell cytometry
2011-01-01
Background siRNA technology is a promising tool for gene therapy of vascular disease. Due to the multitude of reagents and cell types, RNAi experiment optimization can be time-consuming. In this study adherent cell cytometry was used to rapidly optimize siRNA transfection in human aortic vascular smooth muscle cells (AoSMC). Methods AoSMC were seeded at a density of 3000-8000 cells/well of a 96well plate. 24 hours later AoSMC were transfected with either non-targeting unlabeled siRNA (50 nM), or non-targeting labeled siRNA, siGLO Red (5 or 50 nM) using no transfection reagent, HiPerfect or Lipofectamine RNAiMax. For counting cells, Hoechst nuclei stain or Cell Tracker green were used. For data analysis an adherent cell cytometer, Celigo® was used. Data was normalized to the transfection reagent alone group and expressed as red pixel count/cell. Results After 24 hours, none of the transfection conditions led to cell loss. Red fluorescence counts were normalized to the AoSMC count. RNAiMax was more potent compared to HiPerfect or no transfection reagent at 5 nM siGLO Red (4.12 +/-1.04 vs. 0.70 +/-0.26 vs. 0.15 +/-0.13 red pixel/cell) and 50 nM siGLO Red (6.49 +/-1.81 vs. 2.52 +/-0.67 vs. 0.34 +/-0.19). Fluorescence expression results supported gene knockdown achieved by using MARCKS targeting siRNA in AoSMCs. Conclusion This study underscores that RNAi delivery depends heavily on the choice of delivery method. Adherent cell cytometry can be used as a high throughput-screening tool for the optimization of RNAi assays. This technology can accelerate in vitro cell assays and thus save costs. PMID:21518450
Morphological and compositional study of 238U thin film targets for nuclear experiments
NASA Astrophysics Data System (ADS)
Sibbens, Goedele; Ernstberger, Markus; Gouder, Thomas; Marouli, Maria; Moens, André; Seibert, Alice; Vanleeuw, David; Zúñiga, Martin Vargas; Wiss, Thierry; Zampella, Mariavittoria; Zuleger, Evelyn
2018-05-01
The uncertainty in neutron cross section values strongly depends on the quality and characteristics of the deposited actinide films which are used as "targets" in the nuclear experiments. Until recently, at the Joint Research Centre in Geel (JRC-Geel), mass and areal densities of actinide layers were determined by measuring activity (using alpha-particle counting), isotopic composition (using thermal ionisation mass spectrometry) and diameter. In this study a series of 238U deposits, prepared by molecular plating and vacuum deposition on different substrates, were characterized with additional non-destructive and destructive analysis techniques. The quality of the deposits was investigated by autoradiography, high-resolution alpha-particle spectrometry, and scanning electron microscopy. The elemental composition was determined by x-ray photoelectron spectroscopy and inductively coupled plasma mass spectrometry. The latter technique was also applied on the U3O8 starting material and the converted UF4 powder. This paper compares the quality and morphology of deposited 238U films prepared by molecular plating and vacuum deposition on various backings, including their elemental composition determined by different characterization techniques. Also discussed are problems in target preparation and characterization.
Enhanced technologies for unattended ground sensor systems
NASA Astrophysics Data System (ADS)
Hartup, David C.
2010-04-01
Progress in several technical areas is being leveraged to advantage in Unattended Ground Sensor (UGS) systems. This paper discusses advanced technologies that are appropriate for use in UGS systems. While some technologies provide evolutionary improvements, other technologies result in revolutionary performance advancements for UGS systems. Some specific technologies discussed include wireless cameras and viewers, commercial PDA-based system programmers and monitors, new materials and techniques for packaging improvements, low power cueing sensor radios, advanced long-haul terrestrial and SATCOM radios, and networked communications. Other technologies covered include advanced target detection algorithms, high pixel count cameras for license plate and facial recognition, small cameras that provide large stand-off distances, video transmissions of target activity instead of still images, sensor fusion algorithms, and control center hardware. The impact of each technology on the overall UGS system architecture is discussed, along with the advantages provided to UGS system users. Areas of analysis include required camera parameters as a function of stand-off distance for license plate and facial recognition applications, power consumption for wireless cameras and viewers, sensor fusion communication requirements, and requirements to practically implement video transmission through UGS systems. Examples of devices that have already been fielded using technology from several of these areas are given.
NASA Astrophysics Data System (ADS)
Nelce Mailoa, Meigy; Marthina Tapotubun, Alfonsina; Matrutty, Theodora E. A. A.
2017-10-01
A study has been conducted to determine the use of Caulerpa sp. Edible coatings on fresh steaks tuna against the presence of microbes during storage at chilling temperatures. In this research, two applied method of edible coating is used, that is dipping and immersion method, with chilling temperature (5°C), storage time (0, 3, 6, 9 days). Each treatment is compared to control (without an edible coating). The results showed that the application of edible coating Caulerpa sp in fresh steaks tuna with soaking and dipping method showed total bacteria increase during storage, but still fulfill the microbiological quality of fresh fish that is maximum total plate 5.0 × 105 cfu/g. Total microbes in fresh steaks tuna were soaked with immersion methods and stored up to 9 days: 2.3 × 105 cfu/g while total microbial on fresh steaks tuna were dipped by dipping method and stored up to 9 days ie 3.4 × 105 cfu/g. So it can be concluded that application method of edible coating Caulerpa sp on fresh steaks tuna soaked better than the method of dipping.
Influence of composition of diluent on populations of yeasts and moulds recovered from raw fruits.
Beuchat, L R; Scouten, A J; Jablonska, J
2002-01-01
The aims of this study were (i) to determine the retention of viability of mycoflora removed from raw fruits, and how this affected diluents used to prepare samples for enumeration of propagules, and (ii) to evaluate the performance of recovery media for supporting colony development. Yeasts and moulds removed from seven types of raw fruit were held in seven diluents for 1 h before plating on dichloran rose bengal chloramphenicol (DRBC) agar and plate count agar supplemented with chloramphenicol (100 micro g ml-1) (PCAC). Significant reductions (P=0.05) in populations of yeasts, moulds, and yeasts plus moulds occurred within the 1 h holding period, regardless of diluent composition. Overall, retention of viability was not influenced by diluent composition, and neither DRBC agar nor PCAC were superior in supporting colony development. The composition of diluents used to prepare food samples for mycological analysis has little affect on the number of yeasts and moulds recovered from seven types of naturally contaminated raw fruit. Both DRBC agar and PCAC are suitable as enumeration media. Diluents and media most often recommended for enumerating yeasts and moulds in foods are appropriate for raw fruits.
Al-Bakri, Amal G; Afifi, Fatma U
2007-01-01
The aim of this study was to screen and evaluate the antimicrobial activity of indigenous Jordanian plant extracts, dissolved in dimethylsulfoxide, using the rapid XTT assay and viable count methods. XTT rapid assay was used for the initial screening of antimicrobial activity for the plant extracts. Antimicrobial activity of potentially active plant extracts was further assessed using the "viable plate count" method. Four degrees of antimicrobial activity (high, moderate, weak and inactive) against Bacillus subtilis, Staphylococcus aureus, Escherichia coli and Pseudomonas aeruginosa, respectively, were recorded. The plant extracts of Hypericum triquetrifolium, Ballota undulata, Ruta chalepensis, Ononis natrix, Paronychia argentea and Marrubium vulgare had shown promising antimicrobial activity. This study showed that while both XTT and viable count methods are comparable when estimating the overall antimicrobial activity of experimental substances, there is no strong linear correlation between the two methods.
Clinical aspects of Candida species carriage in saliva of xerotomic subjects.
Torres, S R; Peixoto, C B; Caldas, D M; Silva, E B; Magalhães, F A C; Uzeda, M; Nucci, M
2003-10-01
In order to investigate the clinical factors that might influence the diversity and the degree of Candida species carriage in saliva, we conducted a cross-sectional study with 133 patients with complaints of xerostomia. Anamnesis, oral examination and collection of chewing-stimulated whole saliva were performed. The samples of saliva were kept refrigerated until they were plated onto CHROMagar Candida; cfu were counted and Candida species were identified by standard methods. There was a high prevalence of mixed Candida colonization. No relationship was found between total Candida cfu counts and variables like gender, age, place of origin, underlying diseases, exposure to medications (except antibiotics), daily habits and salivary flow rates. Oral candidiasis, antibiotic exposure and dental prosthesis wearing were associated with relatively high Candida counts in saliva. Low salivary flow rates predisposed to intense colonization by C. albicans and C. parapsilosis.
A statistical treatment of bioassay pour fractions
NASA Astrophysics Data System (ADS)
Barengoltz, Jack; Hughes, David
A bioassay is a method for estimating the number of bacterial spores on a spacecraft surface for the purpose of demonstrating compliance with planetary protection (PP) requirements (Ref. 1). The details of the process may be seen in the appropriate PP document (e.g., for NASA, Ref. 2). In general, the surface is mechanically sampled with a damp sterile swab or wipe. The completion of the process is colony formation in a growth medium in a plate (Petri dish); the colonies are counted. Consider a set of samples from randomly selected, known areas of one spacecraft surface, for simplicity. One may calculate the mean and standard deviation of the bioburden density, which is the ratio of counts to area sampled. The standard deviation represents an estimate of the variation from place to place of the true bioburden density commingled with the precision of the individual sample counts. The accuracy of individual sample results depends on the equipment used, the collection method, and the culturing method. One aspect that greatly influences the result is the pour fraction, which is the quantity of fluid added to the plates divided by the total fluid used in extracting spores from the sampling equipment. In an analysis of a single sample’s counts due to the pour fraction, one seeks to answer the question: What is the probability that if a certain number of spores are counted with a known pour fraction, that there are an additional number of spores in the part of the rinse not poured. This is given for specific values by the binomial distribution density, where detection (of culturable spores) is success and the probability of success is the pour fraction. A special summation over the binomial distribution, equivalent to adding for all possible values of the true total number of spores, is performed. This distribution when normalized will almost yield the desired quantity. It is the probability that the additional number of spores does not exceed a certain value. Of course, for a desired value of uncertainty, one must invert the calculation. However, this probability of finding exactly the number of spores in the poured part is correct only in the case where all values of the true number of spores greater than or equal to the adjusted count are equally probable. This is not realistic, of course, but the result can only overestimate the uncertainty. So it is useful. In probability speak, one has the conditional probability given any true total number of spores. Therefore one must multiply it by the probability of each possible true count, before the summation. If the counts for a sample set (of which this is one sample) are available, one may use the calculated variance and the normal probability distribution. In this approach, one assumes a normal distribution and neglects the contribution from spatial variation. The former is a common assumption. The latter can only add to the conservatism (over estimate the number of spores at some level of confidence). A more straightforward approach is to assume a Poisson probability distribution for the measured total sample set counts, and use the product of the number of samples and the mean number of counts per sample as the mean of the Poisson distribution. It is necessary to set the total count to 1 in the Poisson distribution when actual total count is zero. Finally, even when the planetary protection requirements for spore burden refer only to the mean values, they require an adjustment for pour fraction and method efficiency (a PP specification based on independent data). The adjusted mean values are a 50/50 proposition (e.g., the probability of the true total counts in the sample set exceeding the estimate is 0.50). However, this is highly unconservative when the total counts are zero. No adjustment to the mean values occurs for either pour fraction or efficiency. The recommended approach is once again to set the total counts to 1, but now applied to the mean values. Then one may apply the corrections to the revised counts. It can be shown by the methods developed in this work that this change is usually conservative enough to increase the level of confidence in the estimate to 0.5. 1. NASA. (2005) Planetary protection provisions for robotic extraterrestrial missions. NPR 8020.12C, April 2005, National Aeronautics and Space Administration, Washington, DC. 2. NASA. (2010) Handbook for the Microbiological Examination of Space Hardware, NASA-HDBK-6022, National Aeronautics and Space Administration, Washington, DC.
Lee, A P; Barbano, D M; Drake, M A
2016-12-01
The cooling rate of raw milk may influence sensory properties and pasteurized shelf life. Under the Pasteurized Milk Ordinance for grade A milk, raw milk may be cooled instantaneously by on-farm heat exchangers but is also acceptable if "cooled to 10°C or less within four (4) hours of the commencement of the first milking." The objective of this study was to determine the effect of raw milk cooling on consumer perception and shelf life. Raw milk (18-21°C) was obtained and transported within 1h of milking to North Carolina State University (Raleigh). The batch of raw milk was split in 2 portions, and a plate heat exchanger was used to quickly cool one portion to <6°C within 1min. The second portion was stored in a jacketed bulk tank and slowly cooled over 4h to <10°C. Milk from 3 consecutive milkings was collected every 12h, with subsequent milkings added to the previous collections. The bulk milk was kept below 10°C while adding milk for the slow cool milk treatment. After 72h, each whole milk was separated; the skim milk was pasteurized at 73 or 78°C for 20 s, homogenized, and held at 4°C. Difference tests (n=75) and consumer acceptance tests (n=100) were conducted to determine if consumers could detect differences among milks. Descriptive analysis and microbial testing for aerobic, psychrotrophic, and psychrotolerant spore counts were conducted through shelf life. The entire experiment was repeated in triplicate. Raw milks averaged 3.3 logcfu/mL by aerobic plate count, <25cfu/mL coliforms, somatic cell count of 300,000 cells/mL, and 3.15±0.07% protein. Psychrotolerant spores were not found in the raw milk. Consumers could not detect differences between cooling treatments of the same pasteurization temperature or between different temperatures of the same cooling treatment. Milks reached sensory failure 49±4d on average after processing, and aerobic counts were between 5 to 7 logcfu/mL. Cooling treatment had no effect on shelf life. These results suggest that pasteurized milk quality is due to a combination of many factors. Raw milk cooling rate is not the most important factor affecting milk quality when raw milk quality is excellent. Copyright © 2016 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
Clinical use of photodynamic antimicrobial chemotherapy for the treatment of deep carious lesions
NASA Astrophysics Data System (ADS)
Guglielmi, Camila De Almeida B.; Simionato, Maria Regina L.; Ramalho, Karen Müller; Imparato, José Carlos P.; Pinheiro, Sérgio Luiz; Luz, Maria A. A. C.
2011-08-01
The purpose of this study was to assess photodynamic antimicrobial chemotherapy (PACT) via irradiation, using a low power laser associated with a photosensitization dye, as an alternative to remove cariogenic microorganisms by drilling. Remaining dentinal samples in deep carious lesions on permanent molars (n = 26) were treated with 0.01% methylene blue dye and irradiated with a low power laser (InGaAIP - indium gallium aluminum phosphide; λ = 660 nm; 100 mW; 320 Jcm-2 90 s; 9J). Samples of dentin from the pulpal wall region were collected with a micropunch before and immediately after PACT and kept in a transport medium for microbiological analysis. Samples were cultured in plates of Brucella blood agar, Mitis Salivarius Bacitracin agar and Rogosa SL agar to determine the total viable bacteria, mutans streptococci and Lactobacillus spp. counts, respectively. After incubation, colony-forming units were counted and microbial reduction was calculated for each group of bacteria. PACT led to statistically significant reductions in mutans streptococci (1.38 log), Lactobacillus spp. (0.93 log), and total viable bacteria (0.91 log). This therapy may be an appropriate approach for the treatment of deep carious lesions using minimally invasive procedures.
Production of crispy bread snacks containing chicken meat and chicken meat powder.
Cakmak, Hulya; Altinel, Burak; Kumcuoglu, Seher; Kisla, Duygu; Tavman, Sebnem
2016-01-01
Chicken meat in two different forms (chicken meat and chicken meat powder) were added into white flour and whole wheat blend baguette bread formulations for protein enrichment and finally developing new and healthy snacks. The chicken meat and powder levels were 10% for white flour baguette, and 15% for whole wheat blend. The dried baguette samples were packaged under 100% N2, and physical, chemical, microbiological and sensorial properties were evaluated during 3 months of storage. Protein content of chicken meat powder added samples were found statistically higher than chicken meat added samples. Hardness of the snacks was significantly affected from type of chicken meat, such as values were higher for chicken meat added samples than chicken meat powder added samples. Lipid oxidation of the snacks was determined by TBA analysis, and TBA value for whole wheat mixture snack with 15% of chicken meat was the highest among all during storage. The highest overall acceptance score was obtained from white flour snack with 10% chicken meat. There was no coliform bacteria detected during storage and the results of yeast-mold count and aerobic plate count of snacks remained between the quantitative ranges.
NASA Astrophysics Data System (ADS)
Marteinsson, V.; Klonowski, A.; Reynisson, E.; Vannier, P.; Sigurdsson, B. D.; Ólafsson, M.
2015-02-01
Colonization of life on Surtsey has been observed systematically since the formation of the island 50 years ago. Although the first colonisers were prokaryotes, such as bacteria and blue-green algae, most studies have been focused on the settlement of plants and animals but less on microbial succession. To explore microbial colonization in diverse soils and the influence of associated vegetation and birds on numbers of environmental bacteria, we collected 45 samples from different soil types on the surface of the island. Total viable bacterial counts were performed with the plate count method at 22, 30 and 37 °C for all soil samples, and the amount of organic matter and nitrogen (N) was measured. Selected samples were also tested for coliforms, faecal coliforms and aerobic and anaerobic bacteria. The subsurface biosphere was investigated by collecting liquid subsurface samples from a 181 m borehole with a special sampler. Diversity analysis of uncultivated biota in samples was performed by 16S rRNA gene sequences analysis and cultivation. Correlation was observed between nutrient deficits and the number of microorganisms in surface soil samples. The lowest number of bacteria (1 × 104-1 × 105 cells g-1) was detected in almost pure pumice but the count was significantly higher (1 × 106-1 × 109 cells g-1) in vegetated soil or pumice with bird droppings. The number of faecal bacteria correlated also to the total number of bacteria and type of soil. Bacteria belonging to Enterobacteriaceae were only detected in vegetated samples and samples containing bird droppings. The human pathogens Salmonella, Campylobacter and Listeria were not in any sample. Both thermophilic bacteria and archaea 16S rDNA sequences were found in the subsurface samples collected at 145 and 172 m depth at 80 and 54 °C, respectively, but no growth was observed in enrichments. The microbiota sequences generally showed low affiliation to any known 16S rRNA gene sequences.
NASA Astrophysics Data System (ADS)
Marteinsson, V.; Klonowski, A.; Reynisson, E.; Vannier, P.; Sigurdsson, B. D.; Ólafsson, M.
2014-09-01
Colonisation of life on Surtsey has been observed systematically since the formation of the island 50 years ago. Although the first colonisers were prokaryotes, such as bacteria and blue-green algae, most studies have been focusing on settlement of plants and animals but less on microbial succession. To explore microbial colonization in diverse soils and the influence of associate vegetation and birds on numbers of environmental bacteria, we collected 45 samples from different soils types on the surface of the island. Total viable bacterial counts were performed with plate count at 22, 30 and 37 °C for all soils samples and the amount of organic matter and nitrogen (N) was measured. Selected samples were also tested for coliforms, faecal coliforms aerobic and anaerobic bacteria. The deep subsurface biosphere was investigated by collecting liquid subsurface samples from a 182 m borehole with a special sampler. Diversity analysis of uncultivated biota in samples was performed by 16S rRNA gene sequences analysis and cultivation. Correlation was observed between N deficits and the number of microorganisms in surface soils samples. The lowest number of bacteria (1 × 104-1 × 105 g-1) was detected in almost pure pumice but the count was significant higher (1 × 106-1 × 109 g-1) in vegetated soil or pumice with bird droppings. The number of faecal bacteria correlated also to the total number of bacteria and type of soil. Bacteria belonging to Enterobacteriaceae were only detected in vegetated and samples containing bird droppings. The human pathogens Salmonella, Campylobacter and Listeria were not in any sample. Both thermophilic bacteria and archaea 16S rDNA sequences were found in the subsurface samples collected at 145 m and 172 m depth at 80 °C and 54 °C, respectively, but no growth was observed in enrichments. The microbiota sequences generally showed low affiliation to any known 16S rRNA gene sequences.
A simple and highly repeatable viral plaque assay for enterovirus 71.
Yin, Yingxian; Xu, Yi; Ou, Zhiying; Su, Ling; Xia, Huimin
2015-04-01
The classic plaque assay is a method for counting infectious viral particles, however its complexity limits its use in a variety of virological experiments. To simplify the operation and to improve the repeatability, we employed an improved plaque assay procedure based on Avicel to make the whole experiment easier and optimize the results on a model of Vero cells infection with Enterovirus 71(EV71). Clear plaques visible to the naked eyes can be formed on a 24-well plate or a 96-well plate without immunostaining. Following further improvement, this plaque assay procedure could be applied to other viruses, being both simple and repeatable. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Bej, A K; McCarty, S C; Atlas, R M
1991-01-01
Multiplex polymerase chain reaction (PCR) and gene probe detection of target lacZ and uidA genes were used to detect total coliform bacteria and Escherichia coli, respectively, for determining water quality. In tests of environmental water samples, the lacZ PCR method gave results statistically equivalent to those of the plate count and defined substrate methods accepted by the U.S. Environmental Protection Agency for water quality monitoring and the uidA PCR method was more sensitive than 4-methylumbelliferyl-beta-D-glucuronide-based defined substrate tests for specific detection of E. coli. Images PMID:1768116
An evaluation of a partial-walled laminar-flow operating room
Whyte, W.; Shaw, B. H.; Freeman, M. A. R.
1974-01-01
This paper contains an assessment of the physical performance of a permanently installed down-flow laminar-flow operating room at the London Hospital. This system employs partial walls extending 0·76 m (2·5 ft.) from the ceiling, from which the air is allowed to issue freely downwards at an initial velocity of about 0·4 m./sec. (80 ft./min.). The usefulness of the partial wall, as compared with a free issuing system, was demonstrated and a comparison made with a fully walled system. It was shown that a fully walled system would be more efficient than a partial-walled system as there was a loss in air velocity of about 20-25% with the partial wall due to the nonconstrained flow of air. This loss would be reflected in an increase in airborne bacterial count and would mean that an increase of 20-25% in the air volume would be required to obtain the same conditions as with the full-walled system. Entrainment of contaminated air was demonstrated but it was concluded that this would be of little consequence in the centre of the clean area, i.e. at the wound site. Sterile instruments, etc., however, on the outside of the clean area, would be more liable to airborne contamination. Bacterial and dust airborne counts taken during total hip operations gave a very low average figure (0·3 bacteria/ft.3 or 10·5/m.3) from which we conclude that the system was about 30 times cleaner in terms of airborne bacteria than a well ventilated conventional operating-room. We concluded that although the partial-walled system was slightly less efficacious than a normal full-walled system, the freedom of movement and of communication for the operating team could in some circumstances outweigh this disadvantage. Sound levels were such that normal conversation was possible with little or no awareness of background noise. ImagesFig. 2Fig. 3Plate 2Plate 2Plate 3Plate 3Plate 1 PMID:4529595
Interlaboratory Evaluation of a Multiplexed High Information Content In Vitro Genotoxicity Assay
Bryce, Steven M.; Bernacki, Derek T.; Bemis, Jeffrey C.; Spellman, Richard A.; Engel, Maria E.; Schuler, Maik; Lorge, Elisabeth; Heikkinen, Pekka T.; Hemmann, Ulrike; Thybaud, Véronique; Wilde, Sabrina; Queisser, Nina; Sutter, Andreas; Zeller, Andreas; Guérard, Melanie; Kirkland, David; Dertinger, Stephen D.
2017-01-01
We previously described a multiplexed in vitro genotoxicity assay based on flow cytometric analysis of detergent-liberated nuclei that are simultaneously stained with propidium iodide and labeled with fluorescent antibodies against p53, γH2AX, and phospho-histone H3. Inclusion of a known number of microspheres provides absolute nuclei counts. The work described herein was undertaken to evaluate the interlaboratory transferability of this assay, commercially known as MultiFlow™ DNA Damage Kit— p53, γH2AX, Phospho-histone H3. For these experiments seven laboratories studied reference chemicals from a group of 84 representing clastogens, aneugens, and non-genotoxicants. TK6 cells were exposed to chemicals in 96-well plates over a range of concentrations for 24 hrs. At 4 and 24 hrs cell aliquots were added to the MultiFlow reagent mix and following a brief incubation period flow cytometric analysis occurred, in most cases directly from a 96-well plate via a robotic walk-away data acquisition system. Multiplexed response data were evaluated using two analysis approaches, one based on global evaluation factors (i.e., cutoff values derived from all inter-laboratory data), and a second based on multinomial logistic regression that considers multiple biomarkers simultaneously. Both data analysis strategies were devised to categorize chemicals as predominately exhibiting a clastogenic, aneugenic, or non-genotoxic mode of action (MoA). Based on the aggregate 231 experiments that were performed, assay sensitivity, specificity, and concordance in relation to a priori MoA grouping were ≥ 92%. These results are encouraging as they suggest that two distinct data analysis strategies can rapidly and reliably predict new chemicals’ predominant genotoxic MoA based on data from an efficient and transferable multiplexed in vitro assay. PMID:28370322
Pavlov, D; de Wet, C M E; Grabow, W O K; Ehlers, M M
2004-05-01
Heterotrophic plate counts (HPCs) are commonly used to assess the general microbiological quality of drinking water. Drinking water quality specifications worldwide recommend HPC limits from 100 to 500 cfu ml(-1). A number of recent studies revealed evidence that these bacteria may not be as harmless as generally accepted. It appears that immuno-compromised individuals are particularly at risk. This would include the very young and very old patients with diseases such as AIDS and patients on therapy for purposes such as organ transplantation and cancer treatment. In this study, 339 bacterial colonies were isolated at random from selected treated and untreated drinking water in South Africa using routine heterotrophic plate count tests. In a first step to screen for potentially pathogenic properties, 188 (55.5%) of the isolates showed alpha- or beta-haemolysis on human- and horse-blood agar media. Subsequent analysis of the haemolytic isolates for enzymatic properties associated with pathogenicity revealed the presence of chondroitinase in 5.3% of the isolates, coagulase in 16.0%, DNase in 60.6%, elastase in 33.0%, fibrinolysin in 53.7%, gelatinase in 62.2%, hyaluronidase in 21.3%, lecithinase in 47.9%, lipase in 54.8% and proteinase in 64.4%. Fluorescein and pyocyanin were not produced by any of the isolates. Among the haemolytic isolates, 77.7% were resistant to oxacillin 1 microg, 59.6% to penicillin G 2 units, 47.3% to penicillin G 10 units, 54.3% to ampicillin 10 microg and 43.1% to ampicillin 25 microg. Cell culture studies revealed that 96% of haemolytic isolates were cytotoxic to HEp-2 cells, and 98.9% of the 181 cytotoxic isolates adhered to HEp-2 or Caco-2 cells. HEp-2 cells were invaded by 43.6%, and Caco-2 cells by 49.7%, of the 181 cytotoxic isolates. The invasion index on HEp-2 cells ranged from 1.9 x 10(-1) to 8.9 x 10(-6), whereas the invasion index on Caco-2 cells varied between 7.7 x 10(-2) and 8.3 x 10(-6). The most commonly isolated genera with these potentially pathogenic features were Aeromonas, Acinetobacter, Aureobacterium, Bacillus, Chryseobacterium, Corynebacterium, Klebsiella, Moraxella, Pseudomonas, Staphylococcus, Tsukamurella and Vibrio. The results obtained in this study support earlier findings on potentially pathogenic features of bacteria detected by routine HPCs on drinking water. These findings are in agreement with some epidemiological studies, which indicated an association between HPCs in drinking water and the incidence of gastroenteritis in consumers. However, the extent of the health risk concerned needs to be defined in more detail for meaningful revision of quality guidelines for HPCs in drinking water. Copyright 2003 Elsevier B.V.
Microbial Populations in Two Swamp Soils of South Carolina
David S. Priester; William R. Harms
1971-01-01
Microbial populations were counted in agar-plated samples of two swamp soils collected in summer and winter. Number of aerobic and anaerobic microorganisms differed significantly among the soils and between seasons. Alluvial soil from the river swamp was high in organic matter, N, K, Ca, and pH and averaged 88 million microorganisms per gram over the growing season....
7 CFR 58.938 - Physical requirements and microbiological limits for sweetened condensed milk.
Code of Federal Regulations, 2013 CFR
2013-01-01
... retain a definite form. (e) Microbiological limits. (1) Coliforms, less than 10 per gram; (2) yeasts, less than 5 per gram; (3) molds, less than 5 per gram; (4) total plate count, less than 1,000 per gram... amount of sediment retained on a lintine disc after a sample composed of 225 grams of product dissolved...
Ecology and thermal inactivation of microbes in and on interplanetary space vehicle components
NASA Technical Reports Server (NTRS)
Campbell, J. E.; Reyes, A. L.; Wehby, A. J.; Crawford, R. G.; Wimsatt, J. C.; Peeler, J. T.
1974-01-01
Dry heat sterilization of spacecraft was investigated by studying the production of spore crops, and thermal inactivation of the spores, and bacillus subtillus. Spore assays were made by conventional plate count methods, and survival curves for the spores are presented. The results indicate that the inherent resistance of spores from a parent cell can be maintained.
NASA Astrophysics Data System (ADS)
Sahlan, Muhamad; Prakoso, Chandra Dwi; Darwita, Risqa Rina; Hermansyah, Heri
2017-02-01
Topical fluoride is proven to have higher efficacy in preventing dental caries with low production cost and easy to apply. The objective of this research is to formulate alternative agent topical fluoride NH4F 5% mixed with extract ethanol propolis (EEP) in the micro-emulsion system that has high stability, antimicrobial activity, and remineralization capability to arrest teeth caries activity. By using total plate count (TPC) analysis, formulation 2.7% EEP; 6,3% surfactant; and 90,9% NH4F shows good perform to inhibit cariogenic bacteria development around 78-80%. Scanning Electron Microscopy (SEM) and Energy Dispersive X-Ray (EDX) result also showed that sample successfully remineralized enamel surface. In addition, sample showed good pH, flavonoid, and polyphenol stability for 40 days.
Effect of Time Lenght Fermentation to Katsuobushi Oxidation Rate As Fish Flavor Based
NASA Astrophysics Data System (ADS)
Amalia, U.; Rianingsih, L.; Wijayanti, I.
2018-02-01
Katsuobushi or dried smoked skipjack had a distinctive flavor and widely used in traditional Japanese cuisine. This study aimed to evaluate the oxidation rate of Katsuobushi with different lenght fermentation. The processing treatment of the product were the differences of fish boiling time (30 min and 60 min) and the lenght of fermentation: 1 week, 2 weeks and 3 weeks. The glutamic acid content, the oxidation rate (thiobarbituric acid and peroxide value) and Total Plate Count of katsuobushi were analyzed statistically using analysis of varians. Significant differences were found among 3 weeks of fermentation compare to 1 weeks fermentation (P < 0.05). The conclusion of this study was katsuobushi with 60 min boiling and 3 weeks fermentation was potential to be developed become basic ingredients for the fish flavor.
Im, Min Chan; Seo, Kwang Won; Bae, Dong Hwa; Lee, Young Ju
2016-01-01
Edible offal meats have recently received significant attention worldwide. However, studies evaluating the microbial quality of diverse edible offal and specifically investigating contamination by pathogens that cause foodborne illnesses are rare. Our study was conducted to investigate the microbiological quality of six kinds of edible offal produced from 11 pigs and 8 cattle slaughterhouses in the Republic of Korea and the prevalence of pathogenic microorganisms such as Salmonella, Clostridium perfringens, Staphylococcus aureus, and Escherichia coli O157:H7 in these products. The values for aerobic plate counts, coliform counts, and E. coli counts in red offal were 1.00 to 6.70, 0 (below 10 CFU) to 4.78, and 0 to 4.00 log CFU/g, respectively. For green offal, the values were 3.00 to 7.00, 1.48 to 6.30, and 0 to 6.00 log CFU/g, respectively. The most frequently detected foodborne pathogen was Salmonella (23.8% prevalence in pig offal and 7.1% prevalence in cattle offal), followed by C. perfringens (11.1 and 7.1%, respectively) and S. aureus (12.7 and 2.4%, respectively). None of the offal samples tested positive for E. coli O157:H7. Considering the microbial quality of offal from Korean slaughterhouses and the prevalence of foodborne pathogens in this material, more refined hygienic standards such as a hazard analysis critical control point system for processing, packing, and transporting edible offal are necessary for preventing further contamination.
Diab-Elschahawi, Magda; Berger, Jutta; Blacky, Alexander; Kimberger, Oliver; Oguz, Ruken; Kuelpmann, Ruediger; Kramer, Axel; Assadian, Ojan
2011-09-01
This study investigated the influence of the size of unidirectional ceiling distribution systems on counts of viable microorganisms recovered at defined sites in operating room (ORs) and on instrument tables during orthopedic surgery. We compared bacterial sedimentation during 80 orthopedic surgeries. A total of 19 surgeries were performed in ORs with a large (518 cm × 380 cm) unidirectional ceiling distribution (colloquially known as laminar air flow [LAF]) ventilation system, 21 procedures in ORs with a small (380 cm × 120 cm) LAF system, and 40 procedures in ORs with no LAF system. Bacterial sedimentation was evaluated using both settle plates and nitrocellulose membranes. Multivariate linear regression analysis revealed that the colony-forming unit count on nitrocellulose membranes positioned on the instrument table was significantly associated only with the size of the unidirectional LAF distribution system (P < .001), not with the duration of the surgical intervention (P = .753) or with the number of persons present during the surgical intervention (P = .291). Our findings indicate that simply having an LAF ventilation system in place will not provide bacteria-free conditions at the surgical site and on the instrument table. In view of the limited number of procedures studied, our findings require confirmation and further investigations on the ideal, but affordable, size of LAF ventilation systems. Copyright © 2011 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Mosby, Inc. All rights reserved.
Development of microchannel plates in advanced wind-tunnel instrumentation
NASA Technical Reports Server (NTRS)
Feller, W. Bruce
1990-01-01
Microchannel plate (MCP) electron multiplier dynamic range has been increased 3 to 4 orders of magnitude at ambient temperatures, through enhanced input count rate capability and reduced background or 'dark' noise. The previous upper limit of roughly 10(exp 7) - 10(exp 8) cm(exp -2)s(exp -1) at ambient has been extended to levels approach 10(exp 10) cm(exp -2)s(exp -1) under continuous dc operation. The lower limit, previously set by an irreducible background component (approximately 0.6 cm(exp -2)s(exp -1)), has been lowered to the cosmic ray limit of .01 cm(exp -2)s(exp -1). The high end improvement was achieved by conductively cooling a very low resistance MCP by bonding it to a heat sink, while maintaining pulse-counting operation with multianode readouts. The low-end improvement was achieved by removing all radioisotopes from the MCP matrix glass. The detectors will benefit optical and mass spectrometry, flow visualization, plasma diagnostics, magnetometry, and other high signal flux applications. Very low MCP background noise will benefit X-ray and UV astronomy, medical imaging, trace isotope mass spectrometry, and other applications where the signal flux is often extremely low.
Radium-226 body burden in U miners by measurement of Rn in exhaled breath.
Srivastava, G K; Raghavayya, M; Kotrappa, P; Somasundaram, S
1986-02-01
Uranium miners were made to inhale Rn-free medical O2 and exhale through a 5.2-1 A1 chamber before reporting to work. The chamber was sealed and isolated from the sampling circuit. An electrostatic plate collected the freshly formed Rn-decay products. The subsequent programmed alpha counting of the plate yielded a Rn concentration in the exhaled breath. Assuming that the exhaled breath represents a certain fraction of the Rn produced inside the body, the body burden of 226Ra was calculated. Standardisation of this procedure and the data collected on 310 miners are discussed. The procedure is simple and applicable for routine measurements. The miner needs to be in the laboratory for only 10 min. The system is also portable for field application. For routine use, the minimum detectable concentration is 3.87 Bq X m-3 which corresponds to a body burden of 0.26 kBq in a typical miner, if one assumes the Rn release fraction from the body as 84%. The system offers a more convenient and sensitive alternative to whole-body counting of workers for 226Ra.
Ishmayana, Safri; Kennedy, Ursula J; Learmonth, Robert P
2017-11-27
Membrane lipid unsaturation index and membrane fluidity have been related to yeast ethanol stress tolerance in published studies, however findings have been inconsistent. In this study, viability reduction on exposure to 18% (v/v) ethanol was compared to membrane fluidity determined by laurdan generalized polarization. Furthermore, in the determination of viability reduction, we examined the effectiveness of two methods, namely total plate count and methylene violet staining. We found a strong negative correlation between ethanol tolerance and membrane fluidity, indicated by negative Pearson correlation coefficients of - 0.79, - 0.65 and - 0.69 for Saccharomyces cerevisiae strains A12, PDM and K7, respectively. We found that lower membrane fluidity leads to higher ethanol tolerance, as indicated by decreased viability reduction and higher laurdan generalized polarization in respiratory phase compared to respiro-fermentative phase cells. Total plate count better differentiated ethanol tolerance of yeast cells in different growth phases, while methylene violet staining was better to differentiate ethanol tolerance of the different yeast strains at a particular culture phase. Hence, both viability assessment methods have their own advantages and limitations, which should be considered when comparing stress tolerance in different situations.
Gingerich, T M; Lorca, T; Flick, G J; Pierson, M D; McNair, H M
1999-09-01
Changes in histamine, putrescine, and cadaverine concentrations in bluefish filets (Pomatomus saltatrix) stored at 5, 10, and 15 degrees C were determined using high-performance liquid chromatography. An organoleptic assessment was conducted simultaneously with the biogenic amine analyses. The histamine levels found in fresh bluefish obtained from wholesale seafood distributors ranged between <1 ppm and 99 with an average of 39 ppm. Putrescine and cadaverine were not found in fresh bluefish. Fish fillets stored at each of the three temperatures developed histamine. The greatest accumulation of histamine was observed in fish stored at 15 degrees C, which developed histamine levels as high as 2,200 ppm. Putrescine levels increased at each temperature during storage. Cadaverine was present only in uninoculated bluefish stored at 15 degrees C. Histamine achieved higher levels in bluefish pieces inoculated with Morganella morganii, which demonstrates that bluefish support bacterial histamine formation. Histamine levels at each temperature exceeded the 50-ppm advisory level established by the Food and Drug Administration before 100% sensory rejection. Standard plate counts increased during storage of fish at all temperatures, but the correlation between histamine levels and standard plate count was not significant.
Pathogenic features of heterotrophic plate count bacteria from drinking-water boreholes.
Horn, Suranie; Pieters, Rialet; Bezuidenhout, Carlos
2016-12-01
Evidence suggests that heterotrophic plate count (HPC) bacteria may be hazardous to humans with weakened health. We investigated the pathogenic potential of HPC bacteria from untreated borehole water, consumed by humans, for: their haemolytic properties, the production of extracellular enzymes such as DNase, proteinase, lipase, lecithinase, hyaluronidase and chondroitinase, the effect simulated gastric fluid has on their survival, as well as the bacteria's antibiotic-susceptible profile. HuTu-80 cells acted as model for the human intestine and were exposed to the HPC isolates to determine their effects on the viability of the cells. Several HPC isolates were α- or β-haemolytic, produced two or more extracellular enzymes, survived the SGF treatment, and showed resistance against selected antibiotics. The isolates were also harmful to the human intestinal cells to varying degrees. A novel pathogen score was calculated for each isolate. Bacillus cereus had the highest pathogen index: the pathogenicity of the other bacteria declined as follows: Aeromonas taiwanensis > Aeromonas hydrophila > Bacillus thuringiensis > Alcaligenes faecalis > Pseudomonas sp. > Bacillus pumilus > Brevibacillus sp. > Bacillus subtilis > Bacillus sp. These results demonstrated that the prevailing standards for HPCs in drinking water may expose humans with compromised immune systems to undue risk.
Sun, Shih Hui; Kim, Su Jin; Kwak, Soo Jin; Yoon, Ki Sun
2012-01-01
The use of suitable sanitizers can increase the quality of fresh-cut produce and reduce the risk of foodborne illnesses. The objective of this study was to compare the washing effects of 100 mg/L sodium hypochlorite (SH) and 500 mg/L acidified sodium chlorite (ASC) on the prevention of enzymatic browning and the growth of microbial populations, including aerobic plate counts, E. coli, and coliforms, throughout storage at 4°C and 10°C. Fresh-cut zucchini, cucumbers, green bell peppers, and root vegetables such as potatoes, sweet potatoes, carrots, and radishes were used. Compared to SH washing, ASC washing significantly (p<0.05) reduced microbial contamination on the fresh-cut produce and prevented browning of fresh-cut potatoes and sweet potatoes during storage. More effective inhibition of aerobic plate counts and coliforms growth was observed on fresh-cut produce treated with ASC during storage at 10°C. Polyphenol oxidase (PPO) activity of fresh-cut potatoes and sweet potatoes was more effectively inhibited after washing with ASC. The use of 500 mg/L ASC can provide effective antimicrobial and anti-browning treatments of fresh-cut produce, including processed root vegetables. PMID:24471086
Sun, Shih Hui; Kim, Su Jin; Kwak, Soo Jin; Yoon, Ki Sun
2012-09-01
The use of suitable sanitizers can increase the quality of fresh-cut produce and reduce the risk of foodborne illnesses. The objective of this study was to compare the washing effects of 100 mg/L sodium hypochlorite (SH) and 500 mg/L acidified sodium chlorite (ASC) on the prevention of enzymatic browning and the growth of microbial populations, including aerobic plate counts, E. coli, and coliforms, throughout storage at 4°C and 10°C. Fresh-cut zucchini, cucumbers, green bell peppers, and root vegetables such as potatoes, sweet potatoes, carrots, and radishes were used. Compared to SH washing, ASC washing significantly (p<0.05) reduced microbial contamination on the fresh-cut produce and prevented browning of fresh-cut potatoes and sweet potatoes during storage. More effective inhibition of aerobic plate counts and coliforms growth was observed on fresh-cut produce treated with ASC during storage at 10°C. Polyphenol oxidase (PPO) activity of fresh-cut potatoes and sweet potatoes was more effectively inhibited after washing with ASC. The use of 500 mg/L ASC can provide effective antimicrobial and anti-browning treatments of fresh-cut produce, including processed root vegetables.
Cenci-Goga, B T; Ortenzi, R; Bartocci, E; Codega de Oliveira, A; Clementi, F; Vizzani, A
2005-01-01
A study was conducted to evaluate the microbiological quality, including total mesophilic counts and markers of bacteriological hygiene, as indicator of food safety of three categories of the most consumed meals in a university restaurant, before and after implementation of the HACCP system and personnel training. Cold gastronomy products, cooked warm-served products, and cooked cold-served products were tested for bacterial contamination. Throughout the experiment, 894 samples were examined for total counts of aerobic bacteria, counts of indicator organisms (coliform organisms and Escherichia coli) and pathogens (Staphylococcus aureus, Bacillus cereus, Salmonella spp., and Listeria monocytogenes). Implementation of the HACCP system, together with training in personnel hygiene, good manufacturing practices, and cleaning and sanitation procedures, resulted in lower aerobic plate counts and a lower incidence of S. aureus, coliform organisms, E. coli, and B. cereus, whereas Salmonella spp. and L. monocytogenes were not found in all samples studied. The microbial results of this study demonstrate that personnel training together with HACCP application contributed to improve the food safety of meals served in the restaurant studied.
Guarddon, Mónica; Miranda, Jose M; Vázquez, Beatriz I; Cepeda, Alberto; Franco, Carlos M
2012-07-01
The evolution of antimicrobial-resistant bacteria has become a threat to food safety and methods to control them are necessary. Counts of tetracycline-resistant (TR) bacteria by microbiological methods were compared with those obtained by quantitative PCR (qPCR) in 80 meat samples. TR Enterobacteriaceae counts were similar between the count plate method and qPCR (P= 0.24), whereas TR aerobic mesophilic bacteria counts were significantly higher by the microbiological method (P < 0.001). The distribution of tetA and tetB genes was investigated in different types of meat. tetA was detected in chicken meat (40%), turkey meat (100%), pork (20%), and beef (40%) samples, whereas tetB was detected in chicken meat (45%), turkey meat (70%), pork (30%), and beef (35%) samples. The presence of tetracycline residues was also investigated by a receptor assay. This study offers an alternative and rapid method for monitoring the presence of TR bacteria in meat and furthers the understanding of the distribution of tetA and tetB genes. © 2012 Institute of Food Technologists®
Zhou, Xin; Cao, Peng; Zhu, Ye; Lu, Wuguang; Gu, Ning; Mao, Chuanbin
2015-10-01
The ability to count biomolecules such as cancer-biomarker miRNAs with the naked eye is seemingly impossible in molecular diagnostics. Here, we show an ultrasensitive naked-eye-counting strategy for quantifying miRNAs by employing T7 phage-a bacteria-specific virus nanoparticle-as a surrogate. The phage is genetically engineered to become fluorescent and capable of binding a miRNA-capturing gold nanoparticle (GNP) in a one-to-one manner. Target miRNAs crosslink the resultant phage-GNP couple and miRNA-capturing magnetic microparticles, forming a sandwich complex containing equimolar phage and miRNA. The phage is then released from the complex and developed into one macroscopic fluorescent plaque in a Petri dish by plating it in a host bacterial medium. Counting the plaques by the naked eye enables the quantification of miRNAs with detection limits of ∼3 and ∼5 aM for single-target and two-target miRNAs, respectively. This approach offers ultrasensitive and convenient quantification of disease biomarkers by the naked eye.
NASA Astrophysics Data System (ADS)
Zhou, Xin; Cao, Peng; Zhu, Ye; Lu, Wuguang; Gu, Ning; Mao, Chuanbin
2015-10-01
The ability to count biomolecules such as cancer-biomarker miRNAs with the naked eye is seemingly impossible in molecular diagnostics. Here, we show an ultrasensitive naked-eye-counting strategy for quantifying miRNAs by employing T7 phage--a bacteria-specific virus nanoparticle--as a surrogate. The phage is genetically engineered to become fluorescent and capable of binding a miRNA-capturing gold nanoparticle (GNP) in a one-to-one manner. Target miRNAs crosslink the resultant phage-GNP couple and miRNA-capturing magnetic microparticles, forming a sandwich complex containing equimolar phage and miRNA. The phage is then released from the complex and developed into one macroscopic fluorescent plaque in a Petri dish by plating it in a host bacterial medium. Counting the plaques by the naked eye enables the quantification of miRNAs with detection limits of ~3 and ~5 aM for single-target and two-target miRNAs, respectively. This approach offers ultrasensitive and convenient quantification of disease biomarkers by the naked eye.
A System for Photon-Counting Spectrophotometry of Prompt Optical Emission from Gamma-Ray Bursts
NASA Astrophysics Data System (ADS)
Vestrand, W. T.; Albright, K.; Casperson, D.; Fenimore, E.; Ho, C.; Priedhorsky, W.; White, R.; Wren, J.
2003-04-01
With the launch of HETE-2 and the coming launch of the Swift satellite, there will be many new opportunities to study the physics of the prompt optical emission with robotic ground-based telescopes. Time-resolved spectrophotometry of the rapidly varying optical emission is likely to be a rich area for discovery. We describe a program to apply state-of-the-art photon-counting imaging technology to the study of prompt optical emission from gamma-ray bursts. The Remote Ultra-Low Light Imaging (RULLI) project at Los Alamos National Laboratory has developed an imaging sensor which employs stacked microchannel plates and a crossed delay line readout with 200 picosecond photon timing to measure the time of arrival and positions for individual optical photons. RULLI detectors, when coupled with a transmission grating having 300 grooves/mm, can make photon-counting spectroscopic observations with spectral resolution that is an order of magnitude greater and temporal resolution three orders of magnitude greater than the most capable photon-counting imaging detectors that have been used for optical astronomy.
Türetgen, Irfan; Cotuk, Aysin
2007-02-01
Cooling towers have the potential to develop infectious concentrations of Legionella pneumophila. Legionella counts increases where biofilm and warm water temperatures are present. In this study, biofilm associated L. pneumophila and heterotrophic bacteria were compared in terms of material dependence. Model cooling tower system was experimentally infected by L. pneumophila standard strain and monthly monitored. Different materials were tested for a period of 180 days. The lowest L. pneumophila and heterotrophic plate counts were measured on plastic polymers, whereas L. pneumophila and heterotrophic bacteria were accumulated rapidly on galvanized steel surfaces. It can be concluded that selection of plastic polymers, as a manufacturing material, are suitable for recirculating water systems.
NASA Technical Reports Server (NTRS)
Nikzad, Shouleh; Hoenk, M. E.; Carver, A. G.; Jones, T. J.; Greer, F.; Hamden, E.; Goodsall, T.
2013-01-01
In this paper we discuss the high throughput end-to-end post fabrication processing of high performance delta-doped and superlattice-doped silicon imagers for UV, visible, and NIR applications. As an example, we present our results on far ultraviolet and ultraviolet quantum efficiency (QE) in a photon counting, detector array. We have improved the QE by nearly an order of magnitude over microchannel plates (MCPs) that are the state-of-the-art UV detectors for many NASA space missions as well as defense applications. These achievements are made possible by precision interface band engineering of Molecular Beam Epitaxy (MBE) and Atomic Layer Deposition (ALD).
NASA Technical Reports Server (NTRS)
Viswanathan, A. V.; Soong, T.; Miller, R. E., Jr.
1971-01-01
A classical buckling analysis is developed for stiffened, flat plates composed of a series of linked plate and beam elements. Plates are idealized as multilayered orthotropic elements. Structural beads and lips are idealized as beams. The loaded edges of the stiffened plate are simply-supported and the conditions at the unloaded edges can be prescribed arbitrarily. The plate and beam elements are matched along their common junctions for displacement continuity and force equilibrium in an exact manner. Offsets between elements are considered in the analysis. Buckling under uniaxial compressive load for plates, sections, and stiffened plates is investigated. Buckling loads are the lowest of all possible general and local failure modes, and the mode shape is used to determine whether buckling is a local or general instability. Numerical correlations with existing analysis and test data for plates, sections, and stiffened plates including boron-reinforced structures are discussed. In general correlations are reasonably good.
Mehrkash, Milad; Azhari, Mojtaba; Mirdamadi, Hamid Reza
2014-01-01
The importance of elastic wave propagation problem in plates arises from the application of ultrasonic elastic waves in non-destructive evaluation of plate-like structures. However, precise study and analysis of acoustic guided waves especially in non-homogeneous waveguides such as functionally graded plates are so complicated that exact elastodynamic methods are rarely employed in practical applications. Thus, the simple approximate plate theories have attracted much interest for the calculation of wave fields in FGM plates. Therefore, in the current research, the classical plate theory (CPT), first-order shear deformation theory (FSDT) and third-order shear deformation theory (TSDT) are used to obtain the transient responses of flexural waves in FGM plates subjected to transverse impulsive loadings. Moreover, comparing the results with those based on a well recognized hybrid numerical method (HNM), we examine the accuracy of the plate theories for several plates of various thicknesses under excitations of different frequencies. The material properties of the plate are assumed to vary across the plate thickness according to a simple power-law distribution in terms of volume fractions of constituents. In all analyses, spatial Fourier transform together with modal analysis are applied to compute displacement responses of the plates. A comparison of the results demonstrates the reliability ranges of the approximate plate theories for elastic wave propagation analysis in FGM plates. Furthermore, based on various examples, it is shown that whenever the plate theories are used within the appropriate ranges of plate thickness and frequency content, solution process in wave number-time domain based on modal analysis approach is not only sufficient but also efficient for finding the transient waveforms in FGM plates. Copyright © 2013 Elsevier B.V. All rights reserved.
Pothakos, Vasileios; Samapundo, Simbarashe; Devlieghere, Frank
2012-12-01
The major objective of this study was to determine the role of psychrotrophic lactic acid bacteria (LAB) in spoilage-associated phenomena at the end of the shelf-life of 86 various packaged (air, vacuum, modified-atmosphere) chilled-stored retail food products. The current microbiological standards, which are largely based on the total viable mesophilic counts lack discriminatory capacity to detect psychrotrophic LAB. A comparison between the total viable counts on plates incubated at 30 °C (representing the mesophiles) and at 22 °C (indicating the psychrotrophs) for 86 food samples covering a wide range - ready-to-eat vegetable salads, fresh raw meat, cooked meat products and composite food - showed that a consistent underestimation of the microbial load occurs when the total aerobic mesophilic counts are used as a shelf-life parameter. In 38% of the samples, the psychrotrophic counts had significantly higher values (+0.5-3 log CFU/g) than the corresponding total aerobic mesophilic counts. A total of 154 lactic acid bacteria, which were unable to proliferate at 30 °C were isolated. In addition, a further 43 with a poor recovery at this temperature were also isolated. This study highlights the potential fallacy of the total aerobic mesophilic count as a reference shelf-life parameter for chilled food products as it can often underestimate the contamination levels at the end of the shelf-life. Copyright © 2012 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Siegmund, O.; Vallerga, J.; Tremsin, A.; McPhate, J.; Frisch, H.; Elam, J.; Mane, A.; Wagner, R.; Varner, G.
2012-09-01
The development of large area photon counting, imaging, timing detectors with high performance has significance for applications in astronomy (such as our sensor on the SAAO SALT 10m telescope), night time remote reconnaissance, airborne/space situational awareness, and high-speed adaptive optics. Sealed tube configurations for optical/IR sensing also have applications in detection of Cherenkov light (RICH), biological single-molecule fluorescence lifetime imaging microscopy and neutron imaging applications. In open faced configurations these devices are important for UV and particle detection in space astrophysics, mass spectroscopy and many time-of flight applications. Currently available devices are limited to sizes of about 5 cm and use either conventional microchannel plates, or dynode multipliers for amplification, coupled coarse pad array readouts. Extension of these schemes to devices as large as 20 cm with high spatial resolution presents significant problems and potentially considerable cost. A collaboration (Large Area Picosecond Photon Detector) of the U. Chicago, Argonne National Laboratory, U.C. Berkeley, U. Hawaii and a number of other institutions has developed novel technologies to realize 20 cm format detectors in open face or sealed tube configurations. One critical component of this development is novel microchannel plates employing borosilicate micro-capillary arrays. The microchannel plates are based on a novel concept where the substrate is constructed from a borosilicate micro-capillary array that is made to function as a microchannel plate by deposition of resistive and secondary emissive layers using atomic layer deposition. The process is relatively inexpensive compared with conventional microchannel plates and allows very large microchannel plates to be produced with pore sizes as small as 10 microns. These provide many performance characteristics typical of conventional microchannel plates, but have been made in sizes up to 20 cm, have low intrinsic background (<0.1 events/sq-cm/sec) and high stability with no observed gain degradation behavior over at least 5 Coul/sq-cm of charge extraction. Initial tests in a 20 cm detector with a cross strip electronic readout have achieved 4k x 4k pixel imaging with single photon sub-ns timing and MHz event rates. In concert with this effort we have made stable, uniform 20 cm bialkali photocathodes with >20% quantum efficiency on borosilicate windows compatible with a large sealed tube device. Other related efforts have also produced small sealed tubes with 30% quantum efficiency GaAs sealed tubes with high resolution imaging and timing that are immediately applicable to current applications, and opaque GaN UV photocathodes directly deposited onto these novel microchannel plates. We will discuss the details and implications of these novel microchannel plates with respect to the realization of novel detectors up to 20 cm format with reasonable cost and performance, robust construction, high flexibility of format and readout, reduction of fabrication effort, dramatically increased lifetime and stability, and their potential applications.
NASA Astrophysics Data System (ADS)
Boutet, J.; Debourdeau, M.; Laidevant, A.; Hervé, L.; Dinten, J.-M.
2010-02-01
Finding a way to combine ultrasound and fluorescence optical imaging on an endorectal probe may improve early detection of prostate cancer. A trans-rectal probe adapted to fluorescence diffuse optical tomography measurements was developed by our team. This probe is based on a pulsed NIR laser source, an optical fiber network and a time-resolved detection system. A reconstruction algorithm was used to help locate and quantify fluorescent prostate tumors. In this study, two different kinds of time-resolved detectors are compared: High Rate Imaging system (HRI) and a photon counting system. The HRI is based on an intensified multichannel plate and a CCD Camera. The temporal resolution is obtained through a gating of the HRI. Despite a low temporal resolution (300ps), this system allows a simultaneous acquisition of the signal from a large number of detection fibers. In the photon counting setup, 4 photomultipliers are connected to a Time Correlated Single Photon Counting (TCSPC) board, providing a better temporal resolution (0.1 ps) at the expense of a limited number of detection fibers (4). At last, we show that the limited number of detection fibers of the photon counting setup is enough for a good localization and dramatically improves the overall acquisition time. The photon counting approach is then validated through the localization of fluorescent inclusions in a prostate-mimicking phantom.
NASA Technical Reports Server (NTRS)
Whitcomb, John D.
1989-01-01
Strain-energy release rates are often used to predict when delamination growth will occur in laminates under compression. Because of the inherently high computational cost of performing such analyses, less rigorous analyses such as thin-film plate analysis were used. The assumptions imposed by plate theory restrict the analysis to the calculation of total strain energy, G(sub t). The objective is to determine the accuracy of thin-film plate analysis by comparing the distribution of G(sub t) calculated using fully three dimensional (3D), thin-film 3D, and thin-film plate analyses. Thin-film 3D analysis is the same as thin-film plate analysis, except 3D analysis is used to model the sublaminate. The 3D stress analyses were performed using the finite element program NONLIN3D. The plate analysis results were obtained from published data, which used STAGS. Strain-energy release rates were calculated using variations of the virtual crack closure technique. The results demonstrate that thin-film plate analysis can predict the distribution of G(sub t) quite well, at least for the configurations considered. Also, these results verify the accuracy of the strain-energy release rate procedure for plate analysis.
Effects of Jet Fuel Spills on the Microbial Community of Soil †
Song, Hong-Gyu; Bartha, Richard
1990-01-01
Hydrocarbon residues, microbial numbers, and microbial activity were measured and correlated in loam soil contaminated by jet fuel spills resulting in 50 and 135 mg of hydrocarbon g of soil−1. Contaminated soil was incubated at 27°C either as well-aerated surface soil or as poorly aerated subsurface soil. In the former case, the effects of bioremediation treatment on residues, microbial numbers, and microbial activity were also assessed. Hydrocarbon residues were measured by quantitative gas chromatography. Enumerations included direct counts of metabolically active bacteria, measurement of mycelial length, plate counts of aerobic heterotrophs, and most probable numbers of hydrocarbon degraders. Activity was assessed by fluorescein diacetate (FDA) hydrolysis. Jet fuel disappeared much more rapidly from surface soil than it did from subsurface soil. In surface soil, microbial numbers and mycelial length were increased by 2 to 2.5 orders of magnitude as a result of jet fuel contamination alone and by 3 to 4 orders of magnitude as a result of the combination of jet fuel contamination and bioremediation. FDA hydrolysis was stimulated by jet fuel and bioremediation, but was inhibited by jet fuel alone. The latter was traced to an inhibition of the FDA assay by jet fuel biodegradation products. In subsurface soil, oxygen limitation strongly attenuated microbial responses to jet fuel. An increase in the most probable numbers of hydrocarbon degraders was accompanied by a decline in other aerobic heterotrophs, so that total plate counts changed little. The correlations between hydrocarbon residues, microbial numbers, and microbial activity help in elucidating microbial contributions to jet fuel elimination from soil. PMID:16348138
Computer vision-based carbohydrate estimation for type 1 patients with diabetes using smartphones.
Anthimopoulos, Marios; Dehais, Joachim; Shevchik, Sergey; Ransford, Botwey H; Duke, David; Diem, Peter; Mougiakakou, Stavroula
2015-05-01
Individuals with type 1 diabetes (T1D) have to count the carbohydrates (CHOs) of their meal to estimate the prandial insulin dose needed to compensate for the meal's effect on blood glucose levels. CHO counting is very challenging but also crucial, since an error of 20 grams can substantially impair postprandial control. The GoCARB system is a smartphone application designed to support T1D patients with CHO counting of nonpacked foods. In a typical scenario, the user places a reference card next to the dish and acquires 2 images with his/her smartphone. From these images, the plate is detected and the different food items on the plate are automatically segmented and recognized, while their 3D shape is reconstructed. Finally, the food volumes are calculated and the CHO content is estimated by combining the previous results and using the USDA nutritional database. To evaluate the proposed system, a set of 24 multi-food dishes was used. For each dish, 3 pairs of images were taken and for each pair, the system was applied 4 times. The mean absolute percentage error in CHO estimation was 10 ± 12%, which led to a mean absolute error of 6 ± 8 CHO grams for normal-sized dishes. The laboratory experiments demonstrated the feasibility of the GoCARB prototype system since the error was below the initial goal of 20 grams. However, further improvements and evaluation are needed prior launching a system able to meet the inter- and intracultural eating habits. © 2015 Diabetes Technology Society.
Power flow analysis of two coupled plates with arbitrary characteristics
NASA Technical Reports Server (NTRS)
Cuschieri, J. M.
1988-01-01
The limitation of keeping two plates identical is removed and the vibrational power input and output are evaluated for different area ratios, plate thickness ratios, and for different values of the structural damping loss factor for the source plate (plate with excitation) and the receiver plate. In performing this parametric analysis, the source plate characteristics are kept constant. The purpose of this parametric analysis is to be able to determine the most critical parameters that influence the flow of vibrational power from the source plate to the receiver plate. In the case of the structural damping parametric analysis, the influence of changes in the source plate damping is also investigated. As was done previously, results obtained from the mobility power flow approach will be compared to results obtained using a statistical energy analysis (SEA) approach. The significance of the power flow results are discussed together with a discussion and a comparison between SEA results and the mobility power flow results. Furthermore, the benefits that can be derived from using the mobility power flow approach, are also examined.
Microbial and Chemical Shelf-Life of Vacuum Steam-Pasteurized Whole Flaxseed and Milled Flaxseed.
Shah, Manoj; Eklund, Bridget; Conde Lima, Luiz Gustavo; Bergholz, Teresa; Hall, Clifford
2018-02-01
Flaxseed is an oilseed with many health benefits. Flaxseed may be consumed raw or in processed form. In the raw form, there is a potential for microbial contamination. Several pasteurization methods have been used to reduce microbial contamination. However, such treatments may affect chemical properties of foods. In this study, vacuum steam-pasteurization was conducted on whole flaxseed and milled flaxseed using 4 different conditions (3 min at 75 °C, 3 min at 90 °C, 9 min at 90 °C, and 3 min at 105 °C). Microbial and chemical shelf-life was monitored for 28 wk (36 wk for aerobic plate counts). Significant reduction (P < 0.05) in microbial counts (total aerobic plate counts, and yeast and mold counts) occurred after pasteurization and during storage of both whole flaxseed and milled flaxseed. Although both the moisture content and a w increased after pasteurization, they were similar to the unpasteurized samples during storage. Peroxide value, free fatty acid, headspace volatiles, fatty acid profiles, oil content, and secoisolariciresinol diglucoside (SDG) content were chemical indices measured. Only small changes were observed in the chemical indices after vacuum steam-pasteurization for both pasteurized whole flaxseed and milled flaxseed as compared to the unpasteurized flaxseed at most instances. Vacuum steam-pasteurization can be used as a safe alternative for the microbial reduction of low-moisture products, such as flaxseed, without significantly affecting chemical stability. Vacuum steam-pasteurization can be effectively used for the treatment of whole flaxseed and milled flaxseed to reduce spoilage microorganisms, such as total aerobes and yeasts and molds. In addition, this pasteurization method had minimal effects on several chemical shelf-life parameters with positive impact on SDG of the processed flaxseed. © 2018 Institute of Food Technologists®.
Pant, Narayan Dutt; Poudyal, Nimesh; Bhattacharya, Shyamal Kumar
2016-06-07
Water-related diseases are of great concern in developing countries like Nepal. Every year, there are countless morbidity and mortality due to the consumption of unsafe drinking water. Recently, there have been increased uses of bottled drinking water in an assumption that the bottled water is safer than the tap water and its use will help to protect from water-related diseases. So, the main objective of this study was to analyze the bacteriological quality of bottled drinking water and that of municipal tap water. A total of 100 samples (76 tap water and 24 bottled water) were analyzed for bacteriological quality and pH. The methods used were spread plate method for total plate count (TPC) and membrane filter method for total coliform count (TCC), fecal coliform count (FCC), and fecal streptococcal count (FSC). pH meter was used for measuring pH. One hundred percent of the tap water samples and 87.5 % of the bottled water samples were found to be contaminated with heterotrophic bacteria. Of the tap water samples, 55.3 % were positive for total coliforms, compared with 25 % of the bottled water. No bottled water samples were positive for fecal coliforms and fecal streptococci, in contrast to 21.1 % and 14.5 % of the tap water samples being contaminated with fecal coliforms and fecal streptococci, respectively. One hundred percent of the tap water samples and 54.2 % of the bottled water samples had pH in the acceptable range. All of the municipal tap water samples and most of the bottled drinking water samples distributed in Dharan municipality were found to be contaminated with one or more than one type of indicator organisms. On the basis of our findings, we may conclude that comparatively, the bottled drinking water may have been safer (than tap water) to drink.
Evaluation of microbial survival post-incidence on fresh Mozzarella cheese.
Ganesan, Balasubramanian; Irish, David A; Brothersen, Carl; McMahon, Donald J
2012-12-01
Commercial fresh Mozzarella cheese is made by direct acidification and is stored dry or in water without salt addition. The cheese has a shelf life of 6 wk, but usually develops an off-flavor and loses textural integrity by 4 wk, potentially due to the lack of salt and high moisture that allow the outgrowth of undesirable bacteria. To understand how microbial incidence affects cheese quality and how incident pathogen-related bacteria are limited by salt level during refrigerated storage, we made fresh Mozzarella cheese with high (2%) and low (0.5%) salt. The high-salt cheese was packaged and stored dry. The low-salt cheese was packaged and stored either dry or in 0.5% salt brine. One portion of cheeses was evaluated for surviving incident microbes by aerobic plate counts, coliform counts, and psychrophilic bacterial counts, of which coliforms and psychrophiles were not detected over 9 wk. Aerobic plate counts remained at 100 to 300 cfu/g up to 2 wk but increased by 1,000- to 10,000-fold between 4 and 6 wk at all salt levels and storage conditions. Other portions of cheeses were inoculated with either Escherichia coli or Enterococcus faecalis, both of which increased by 100-fold over 90 d of storage. Interestingly, E. coli added to the cheese brine first grew in the brine by 100-fold before attaching to the cheese, whereas Ent. faecalis attached to the cheese within 24h and grew only on the cheese. We conclude that incident bacteria, even from similar environments, may attach to cheese curd and survive differently in fresh Mozzarella cheese than in brine. Overall, 2% salt was insufficient to control bacterial growth, and slow-growing, cold- and salt-tolerant bacteria may survive and spoil fresh Mozzarella cheese. Copyright © 2012 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
Zago, Miriam; Scaltriti, Erika; Fornasari, Maria Emanuela; Rivetti, Claudio; Grolli, Stefano; Giraffa, Giorgio; Ramoni, Roberto; Carminati, Domenico
2012-01-01
Bacteriophages attacking lactic acid bacteria (LAB) still represent a crucial problem in industrial dairy fermentations. The consequences of a phage infection against LAB can lead to fermentation delay, alteration of the product quality and, in most severe cases, the product loss. Phage particles enumeration and phage-host interactions are normally evaluated by conventional plaque count assays, but, in many cases, these methods can be unsuccessful. Bacteriophages of Lactobacillus helveticus, a LAB species widely used as dairy starter or probiotic cultures, are often unable to form lysis plaques, thus impairing their enumeration by plate assay. In this study, we used epifluorescence microscopy to enumerate L. helveticus phage particles from phage-infected cultures and Atomic Force Microscopy (AFM) to visualize both phages and bacteria during the different stages of the lytic cycle. Preliminary, we tested the sensitivity of phage counting by epifluorescence microscopy. To this end, phage particles of ΦAQ113, a lytic phage of L. helveticus isolated from a whey starter culture, were stained by SYBR Green I and enumerated by epifluorescence microscopy. Values obtained by the microscopic method were 10 times higher than plate counts, with a lowest sensitivity limit of ≥6log phage/ml. The interaction of phage ΦAQ113 with its host cell L. helveticus Lh1405 was imaged by AFM after 0, 2 and 5h from phage-host adsorption. The lytic cycle was followed by epifluorescence microscopy counting and the concomitant cell wall changes were visualized by AFM imaging. Our results showed that these two methods can be combined for a reliable phage enumeration and for studying phage and host morphology during infection processes, thus giving a complete overview of phage-host interactions in L. helveticus strains involved in dairy productions. Copyright © 2011 Elsevier B.V. All rights reserved.
Buckling analysis for structural sections and stiffened plates reinforced with laminated composites.
NASA Technical Reports Server (NTRS)
Viswanathan, A. V.; Soong, T.-C.; Miller, R. E., Jr.
1972-01-01
A classical buckling analysis is developed for stiffened, flat plates composed of a series of linked flat plate and beam elements. Plates are idealized as multilayered orthotropic elements; structural beads and lips are idealized as beams. The loaded edges of the stiffened plate are simply supported and the conditions at the unloaded edges can be prescribed arbitrarily. The plate and beam elements are matched along their common junctions for displacement continuity and force equilibrium in an exact manner. Offsets between elements are considered in the analysis. Buckling under uniaxial compressive load for plates, sections and stiffened plates is investigated. Buckling loads are found as the lowest of all possible general and local failure modes and the mode shape is used to determine whether buckling is a local or general instability. Numerical correlations with existing analysis and test data for plates, sections and stiffened plates including boron-reinforced structures are discussed. In general, correlations are reasonably good.
1985-03-01
used to remove trichloroethylene (TCE) from contaminated well water. 7 MATERIALS Chemicals: Trichloroethylene (Aldrich chemical, Milwaukee, WI), sodium ...Cleveland, OH), sodium hydrcxide (J.T. Baker, Phillipsburg, NJ), potassium dichloroisocyanurate (Dorex Inc., Frankfort, IL), potassium iodide starch...NJ). Media and Reagents: Plate count agar (Difco Laboratories, Detroit, MI), lauryl tryptose broth (Difco Laboratories, Detroit, MI), motility medium
The use of coliform plate count data to assess stream sanitary and ecological condition is limited by the need to store samples at 4oC and analyze them within a 24-hour period. We are testing LH-PCR as an alternative tool to assess the bacterial load of streams, offering a cost ...
Retreived bacteria from Noctiluca miliaris (green) bloom of the northeastern Arabian Sea
NASA Astrophysics Data System (ADS)
Basu, Subhajit; Matondkar, S. G. Prabhu; Furtado, Irene
2013-01-01
In recent years, seasonal blooms of the dinoflagellate Noctiluca miliaris have appeared in the open-waters of the northern Arabian Sea (NAS). This study provides the first characterization of bacteria from a seasonal bloom of green Noctiluca of NAS (20°N-17°N and 64°E-70°E), during the spring-inter-monsoon cruise of Sagar Sampada 253, in March 2007. Bacterial growth as assessed by most-probable number (MPN) and plate counts, revealed `variable-physiotypes' over a wide range of salinities (0%-25% w/v NaCl), pH levels (5-8.5), and organic nutrient strengths, in comparison to non-bloom waters. MPN indices of bacteria in surface waters of bloom stations *DWK and *PRB, corresponded to (3.08-4.41)×103 cells/mL at 3.5% NaCl (w/v), and (2.82-9.49)×102 cells/mL at 25% (w/v) NaCl in tryptone-yeast extract broth (TYE). Plate counts were (1.12-4)×106 CFU/mL at 0% (w/v) NaCl, (1.28-3.9)×106 CFU/mL at 3.5% (w/v) NaCl, and (0.4-7)×104 CFU/mL at 25% NaCl (w/v) on TYE. One-tenth-strength Zobell's gave (0.6-3.74)×105 CFU/mL at pH 5 to (3.58-7.5)×105 CFU/mL at pH 8.5. These bacteria were identified to the genera Bacillus, Cellulomonas, Staphylococcus, Planococcus, Dietzia, Virgibacillus, Micrococcus, Sporosarcinae, Leucobacter, and Halomonas. The identity of three strains (GUFBSS253N2, GUFBSS253N30, and GUFBSS253N84) was confirmed through 16S rDNA sequence homology as Bacillus cohnii, Bacillus flexus, and Bacillus cereus. The ˜2-3-fold higher plate counts of culturable bacteria from the open-waters of the NAS indicate that these bacteria could critically determine the biogeochemical dynamics of the bloom and its milieu. The role of these bacteria in sustaining/terminating the bloom is under evaluation.
Tomasino, Stephen F; Fiumara, Rebecca M; Cottrill, Michele P
2006-01-01
The AOAC Use-Dilution methods do not provide procedures to enumerate the test microbe on stainless steel carriers (penicylinders) or guidance on the expected target populations of the test microbe (i.e., a performance standard). This report describes the procedures used by the U.S. Environmental Protection Agency to enumerate the test microbe (carrier counts) associated with conducting the Use-Dilution method with Staphylococcus aureus (Method 955.15) and Pseudomonas aeruginosa (Method 964.02) and the examination of historical data. The carrier count procedure involves the random selection of carriers, shearing bacterial cells from the carrier surface through sonication, and plating of serially diluted inoculum on trypticase soy agar. For each Use-Dilution test conducted, the official AOAC method was strictly followed for carrier preparation, culture initiation, test culture preparation, and carrier inoculation steps. Carrier count data from 78 Use-Dilution tests conducted over a 6-year period were compiled and analyzed. A mean carrier count of 6.6 logs (approximately 4.0 x 10(6) colony-forming units/carrier) was calculated for both S. aureus and P. aeruginosa. Of the mean values, 95% fell within +/- 2 repeatability standard deviations. The enumeration procedure and target carrier counts are desirable for standardizing the Use-Dilution methods, increasing their reproducibility, and ensuring the quality of the data.
Puesta en marcha de un microdensitómetro automático basado en CCD
NASA Astrophysics Data System (ADS)
Calderón, J. H.; Bustos Fierro, I. H.
We present the commisioning of a CCD-based microdensitometer intended to perform astrometric measurements of photographic plates. The work done consisted in the installation of a CCD camera, the modification of the motion system, the construction of a new illumination device, the adaptation of the electronics, and the development of software. The instrument is intended to be used for the astrometric measurement mainly of plates of the Astrographic Catalog and Carte du Ciel collections from Córdoba Observatory. In this phase of the project we counted with the collaboration of the Instituto Provincial de Enseñanza Media No 59, 25 de Mayo, Cruz Alta (Province of Córdoba). The origin and importance of such collaboration is commented.
Aftershocks to Philippine quake found within nearby megathrust fault
NASA Astrophysics Data System (ADS)
Schultz, Colin
2013-02-01
On 31 August 2012 a magnitude 7.6 earthquake ruptured deep beneath the sea floor of the Philippine Trench, a powerful intraplate earthquake centered seaward of the plate boundary. In the wake of the main shock, sensors detected a flurry of aftershocks, counting 110 in total. Drawing on seismic wave observations and rupture mechanisms calculated for the aftershocks, Ye et al. found that many were located near the epicenter of the main intraplate quake but at shallower depth; all involved normal faulting. Some shallow thrusting aftershocks were located farther to the west, centered within the potentially dangerous megathrust fault formed by the subduction of the Philippine Sea plate beneath the Philippine microplate, the piece of crust housing the Philippine Islands.
Modeling of composite beams and plates for static and dynamic analysis
NASA Technical Reports Server (NTRS)
Hodges, Dewey H.
1992-01-01
A rigorous theory and the corresponding computational algorithms were developed for through-the-thickness analysis of composite plates. This type of analysis is needed in order to find the elastic stiffness constants of a plate. Additionally, the analysis is used to post-process the resulting plate solution in order to find approximate three-dimensional displacement, strain, and stress distributions throughout the plate. It was decided that the variational-asymptotical method (VAM) would serve as a suitable framework in which to solve these types of problems. Work during this reporting period has progressed along two lines: (1) further evaluation of neo-classical plate theory (NCPT) as applied to shear-coupled laminates; and (2) continued modeling of plates with nonuniform thickness.
Flexural Plate Wave Devices for Chemical Analysis
1991-04-16
Naval Research Laboratory Washi..gton. DC 20375-5000 NRL Memorandum Report 6815 AD-A234 129 Flexural Plate Wave Devices for Chemical Analysis JAY W...4. TITLE AND SUBTITLE S. FUNDING NUMBERS Flexural Plate Wave Devices for Chemical Analysis 6. AUTHOR(S) 61-1638-01 Jay W. Grate. Stuart W. Wenzel... ANALYSIS INTRODUCTION Flexural plate wave (FPW) devices offer many attractive features for chemical analysis (1-9). As gravimetric sensors for chemical
Power flow analysis of two coupled plates with arbitrary characteristics
NASA Technical Reports Server (NTRS)
Cuschieri, J. M.
1990-01-01
In the last progress report (Feb. 1988) some results were presented for a parametric analysis on the vibrational power flow between two coupled plate structures using the mobility power flow approach. The results reported then were for changes in the structural parameters of the two plates, but with the two plates identical in their structural characteristics. Herein, limitation is removed. The vibrational power input and output are evaluated for different values of the structural damping loss factor for the source and receiver plates. In performing this parametric analysis, the source plate characteristics are kept constant. The purpose of this parametric analysis is to determine the most critical parameters that influence the flow of vibrational power from the source plate to the receiver plate. In the case of the structural damping parametric analysis, the influence of changes in the source plate damping is also investigated. The results obtained from the mobility power flow approach are compared to results obtained using a statistical energy analysis (SEA) approach. The significance of the power flow results are discussed together with a discussion and a comparison between the SEA results and the mobility power flow results. Furthermore, the benefits derived from using the mobility power flow approach are examined.
NASA Technical Reports Server (NTRS)
Krishnamurthy, Thiagarajan
2010-01-01
Equivalent plate analysis is often used to replace the computationally expensive finite element analysis in initial design stages or in conceptual design of aircraft wing structures. The equivalent plate model can also be used to design a wind tunnel model to match the stiffness characteristics of the wing box of a full-scale aircraft wing model while satisfying strength-based requirements An equivalent plate analysis technique is presented to predict the static and dynamic response of an aircraft wing with or without damage. First, a geometric scale factor and a dynamic pressure scale factor are defined to relate the stiffness, load and deformation of the equivalent plate to the aircraft wing. A procedure using an optimization technique is presented to create scaled equivalent plate models from the full scale aircraft wing using geometric and dynamic pressure scale factors. The scaled models are constructed by matching the stiffness of the scaled equivalent plate with the scaled aircraft wing stiffness. It is demonstrated that the scaled equivalent plate model can be used to predict the deformation of the aircraft wing accurately. Once the full equivalent plate geometry is obtained, any other scaled equivalent plate geometry can be obtained using the geometric scale factor. Next, an average frequency scale factor is defined as the average ratio of the frequencies of the aircraft wing to the frequencies of the full-scaled equivalent plate. The average frequency scale factor combined with the geometric scale factor is used to predict the frequency response of the aircraft wing from the scaled equivalent plate analysis. A procedure is outlined to estimate the frequency response and the flutter speed of an aircraft wing from the equivalent plate analysis using the frequency scale factor and geometric scale factor. The equivalent plate analysis is demonstrated using an aircraft wing without damage and another with damage. Both of the problems show that the scaled equivalent plate analysis can be successfully used to predict the frequencies and flutter speed of a typical aircraft wing.
NASA Astrophysics Data System (ADS)
Fenske, Roger; Näther, Dirk U.; Dennis, Richard B.; Smith, S. Desmond
2010-02-01
Commercial Fluorescence Lifetime Spectrometers have long suffered from the lack of a simple, compact and relatively inexpensive broad spectral band light source that can be flexibly employed for both quasi-steady state and time resolved measurements (using Time Correlated Single Photon Counting [TCSPC]). This paper reports the integration of an optically pumped photonic crystal fibre, supercontinuum source1 (Fianium model SC400PP) as a light source in Fluorescence Lifetime Spectrometers (Edinburgh Instruments FLS920 and Lifespec II), with single photon counting detectors (micro-channel plate photomultiplier and a near-infrared photomultiplier) covering the UV to NIR range. An innovative method of spectral selection of the supercontinuum source involving wedge interference filters is also discussed.
Breazeale, F. W.; Camper, N. D.
1970-01-01
Soil samples were collected from an untreated plot and plots receiving repeated applications of 2,4-dichlorophenoxyacetic acid (2,4-D) and α,α,α-trifluoro-2, 6-dinitro-N,N-dipropyl-p-toluidine (trifluralin); they were then plated on media specific for bacteria, fungi, and actinomycetes. The actinomycete colony count in the trifluralin-treated plot was greater than the control, but the same as the control in the 2,4-D-treated plot. The bacterial count was lower in both treated plots. Fungal colonies in the trifluralin-treated plots were greater than the control, but not different from the control in the 2,4-D-treated plot. PMID:5437308
High altitude hypoxia as a factor that promotes tibial growth plate development in broiler chickens
Huang, Shucheng; Zhang, Lihong; Rehman, Mujeeb Ur; Iqbal, Muhammad Kashif; Lan, Yanfang; Mehmood, Khalid; Zhang, Hui; Qiu, Gang; Nabi, Fazul; Yao, Wangyuan; Wang, Meng; Li, Jiakui
2017-01-01
Tibial dyschondroplasia (TD) is one of the most common problems in the poultry industry and leads to lameness by affecting the proximal growth plate of the tibia. However, due to the unique environmental and geographical conditions of Tibet, no case of TD has been reported in Tibetan chickens (TBCs). The present study was designed to investigate the effect of high altitude hypoxia on blood parameters and tibial growth plate development in chickens using the complete blood count, morphology, and histological examination. The results of this study showed an undesirable impact on the overall performance, body weight, and mortality of Arbor Acres chickens (AACs) exposed to a high altitude hypoxic environment. However, AACs raised under hypoxic conditions showed an elevated number of red blood cells (RBCs) and an increase in hemoglobin and hematocrit values on day 14 compared to the hypobaric normoxia group. Notably, the morphology and histology analyses showed that the size of tibial growth plates in AACs was enlarged and that the blood vessel density was also higher after exposure to the hypoxic environment for 14 days, while no such change was observed in TBCs. Altogether, our results revealed that the hypoxic environment has a potentially new role in increasing the blood vessel density of proximal tibial growth plates to strengthen and enhance the size of the growth plates, which may provide new insights for the therapeutic manipulation of hypoxia in poultry TD. PMID:28282429
Thomas, Pious; Sekhar, Aparna C; Upreti, Reshmi; Mujawar, Mohammad M; Pasha, Sadiq S
2015-12-01
We propose a simple technique for bacterial and yeast cfu estimations from diverse samples with no prior idea of viable counts, designated as single plate-serial dilution spotting (SP-SDS) with the prime recommendation of sample anchoring (10 0 stocks). For pure cultures, serial dilutions were prepared from 0.1 OD (10 0 ) stock and 20 μl aliquots of six dilutions (10 1 -10 6 ) were applied as 10-15 micro-drops in six sectors over agar-gelled medium in 9-cm plates. For liquid samples 10 0 -10 5 dilutions, and for colloidal suspensions and solid samples (10% w/v), 10 1 -10 6 dilutions were used. Following incubation, at least one dilution level yielded 6-60 cfu per sector comparable to the standard method involving 100 μl samples. Tested on diverse bacteria, composite samples and Saccharomyces cerevisiae , SP-SDS offered wider applicability over alternative methods like drop-plating and track-dilution for cfu estimation, single colony isolation and culture purity testing, particularly suiting low resource settings.
[Physicochemical and microbiological evaluation of 3 commercial guava jams (Psidium guajava L.)].
López, R; Ramírez, A O; Graziani de Fariñas, L
2000-09-01
Four different production batches were taken from each brand. Samples were purchased from retail markets in Maracay, Cagua and Turmero. (Venezuela). The average physical and chemical values were: vacuum = 38.81 cm Hg; pH = 3.28; titrable acidity (%citric acid) = 0.59%; degree Brix = 67.24; reducing sugars = 55.28%; total sugars = 62.28, and the color parameters a = +14.44, b = +8.77 and L = 17.09. Molds, yeast and aerobic plate counts were lower than 10 UFC/g; it reveals an excellent microbiological quality of the product. The studied jams degree Brix and acidity fulfil COVENIN (1) requirements for jam products, but not pH range. In agreement with variance analysis, there were highly significance differences between the samples and among the shares of each sample for all physical and chemical properties evaluated.
High-speed MCP anodes for high time resolution low-energy charged particle spectrometers
NASA Astrophysics Data System (ADS)
Saito, Yoshifumi; Yokota, Shoichiro; Asamura, Kazushi; Krieger, Amanda
2017-02-01
The time resolution of low-energy charged particle measurements is becoming higher and higher. In order to realize high time resolution measurements, a 1-D circular delay line anode has been developed as a high-speed microchannel plate (MCP) anode. The maximum count rate of the 1-D circular delay line anode is around 1 × 107/s/360°, which is much higher than the widely used resistive anode, whose maximum count rate is around 1 × 106/s/360°. In order to achieve much higher speeds, an MCP anode with application-specific integrated circuit (ASIC) has been developed. We have decided to adopt an anode configuration in which a discrete anode is formed on a ceramic substrate, and a bare ASIC chip is installed on the back of the ceramic. It has been found that the anode can detect at a high count rate of 2 × 108/s/360°. Developments in both delay line and discrete anodes, as well as readout electronics, will be reviewed.
Accelerated dry curing of hams.
Marriott, N G; Kelly, R F; Shaffer, C K; Graham, P P; Boling, J W
1985-01-01
Uncured pork legs from the right side of 18 carcasses were treated with a Ross Tenderizer and the left side were controls. All 36 samples were dry-cured for 40, 56 or 70 days and evaluated for appearance traits, cure penetration characteristics, microbial load, Kramer Shear force and taste attributes. The tenderization treatment had no effect (P > 0·05) on visual color or cure penetration rate, weight loss before curing, percentage moisture, nitrate level, nitrite level, total plate count, anaerobic counts, psychrotrophic counts, objective and subjective tenderness measurements or juiciness. However, the higher values of salt suggested a possible acceleration of the dry cure penetration process among the tenderized samples. Cure time had no effect (P > 0·05) on percentage moisture, percentage salt, nitrate content, nitrite content, shear force and juiciness. Results suggest a limited effect of the mechanical tenderization process on certain traits related to dry curing and that total process time should be at least 70 days if color stability during cooking is desired. Copyright © 1985. Published by Elsevier Ltd.
Image charge multi-role and function detectors
NASA Astrophysics Data System (ADS)
Milnes, James; Lapington, Jon S.; Jagutzki, Ottmar; Howorth, Jon
2009-06-01
The image charge technique used with microchannel plate imaging tubes provides several operational and practical benefits by serving to isolate the electronic image readout from the detector. The simple dielectric interface between detector and readout provides vacuum isolation and no vacuum electrical feed-throughs are required. Since the readout is mechanically separate from the detector, an image tube of generic design can be simply optimised for various applications by attaching it to different readout devices and electronics. We present imaging performance results using a single image tube with a variety of readout devices suited to differing applications: (a) A four electrode charge division tetra wedge anode, optimised for best spatial resolution in photon counting mode. (b) A cross delay line anode, enabling higher count rate, and the possibility of discriminating near co-incident events, and an event timing resolution of better than 1 ns. (c) A multi-anode readout connected, either to a multi-channel oscilloscope for analogue measurements of fast optical pulses, or alternately, to a multi-channel time correlated single photon counting (TCSPC) card.
NASA Technical Reports Server (NTRS)
Strayer, Richard F.; Hummerick, Mary E.; Richards, Jeffrey T.; McCoy, LaShelle E.; Roberts, Michael S.; Wheeler, Raymond M.
2011-01-01
The fate of space-generated solid wastes, including trash, for future missions is under consideration by NASA. Several potential treatment options are under active technology development. Potential fates for space-generated solid wastes: Storage without treatment; storage after treatment(s) including volume reduction, water recovery, sterilization, and recovery plus recycling of waste materials. For this study, a microbial characterization was made on trash returned from four recent STS missions. The material analyzed were 'Volume F' trash and other bags of accompanying trash. This is the second of two submitted papers on these wastes. This first one covered trash content, weight and water content. Upon receipt, usually within 2 days of landing, trash contents were catalogued and placed into categories: drink containers, food waste, personal hygiene items, and packaging materials, i.e., plastic film and duct tape. Microbial counts were obtained with cultivatable counts on agar media and direct counts using Acridine Orange fluorescent stain (AODC). Trash bag surfaces, 25 square cm , were also sampled. Direct counts were approximately 1 x 10(exp 6) microbes/square cm and cultivatable counts ranged from 1 x 10 to 1 X 10(exp 4) microbes/ square cm-2. Aerobic microbes, aerobic sporeformers, and yeasts plus molds were common for all four missions. Waste items from each category were placed into sterile ziplock bags and 1.5 L sterile DI water added. These were then dispersed by hand shaking for 2 min. prior to inoculation of count media or determining AODC. In general, cultivatable microbes were found in drinks, food wastes, and personal hygiene items. Direct counts were usually higher than cultivatable counts. Some pathogens were found: Staphylococcus auerus, Escherichia coli (fecal wastes). Count ranges: drink pouches - AODC 2 x 10(exp 6) to 1 X 10(exp 8) g(sub fw) (exp -1); cultivatable counts variable between missions; food wastes: Direct counts were close to aerobic plate counts. Counts ranged from 10(exp 6) to 10(exp 9) per g(sub fw). Identities of isolates from cultivation media were obtained using a Biolog Microbial ID System or microSEQ molecular ID methodology using an ABI3130 gene analyzer.
Rasdhari, M; Parekh, T; Dave, N; Patel, V; Subhash, R
2008-09-01
The present investigation was carried out to examine the effect of Hibiscus sabdariffa Calyx extract on the physico-chemical properties, sensory attributes, texture and microbial analysis of L. casei incorporated in probiotic yoghurt after manufacture and during storage. Incorporation of Hibiscus sabdariffa Calyx extract into the probiotic yoghurt resulted into decrease in coagulation time by 25 min. The pH ranged from 4.39 to 4.59, TA 0.81 to 1.14%, moisture 3.05 to 3.37 g%, syneresis 18.85 to 24.90 mL/50 g of sample, % inhibition 12.32 to 59.43, TS 21.27 to 24.90 g% and beta-galactosidase activity 1.041 to 3.277. The protein content ranged between 4.11 and 4.14 g% while the fat content ranged between 3.43 and 3.49 g%. No major changes in sensory evaluation were observed on the day of manufacture and during storage for 7 days. Sabdariffa added yoghurt showed a higher score in almost all sensory attributes. Microbial analysis showed a total plate count ranging from 1.8 x 10(4) to 1.85 x 10(7) cfu mL(-1). Yeast and mold counts were negligible in the Sabdariffa yoghurts. Thus the study concludes that incorporation of Hibiscus sabdariffa extract in yoghurt improved the total antioxidant property, organoleptic qualities and decreased the exudation of whey proteins (Syneresis). Thus, Hibiscus sabdariffa Calyces has beneficial influence on the quality of L. casei incorporated probiotic yoghurt.
Fernandes, Richard; Carey, Conn; Hynes, James; Papkovsky, Dmitri
2013-01-01
The importance of food safety has resulted in a demand for a more rapid, high-throughput method for total viable count (TVC). The industry standard for TVC determination (ISO 4833:2003) is widely used but presents users with some drawbacks. The method is materials- and labor-intensive, requiring multiple agar plates per sample. More importantly, the method is slow, with 72 h typically required for a definitive result. Luxcel Biosciences has developed the GreenLight Model 960, a microtiter plate-based assay providing a rapid high-throughput method of aerobic bacterial load assessment through analysis of microbial oxygen consumption. Results are generated in 1-12 h, depending on microbial load. The mix and measure procedure allows rapid detection of microbial oxygen consumption and equates oxygen consumption to microbial load (CFU/g), providing a simple, sensitive means of assessing the microbial contamination levels in foods (1). As bacteria in the test sample grow and respire, they deplete O2, which is detected as an increase in the GreenLight probe signal above the baseline level (2). The time required to reach this increase in signal can be used to calculate the CFU/g of the original sample, based on a predetermined calibration. The higher the initial microbial load, the earlier this threshold is reached (1).
Enrichment of Acinetobacter spp. from food samples.
Carvalheira, Ana; Ferreira, Vânia; Silva, Joana; Teixeira, Paula
2016-05-01
Relatively little is known about the role of foods in the chain of transmission of acinetobacters and the occurrence of different Acinetobacter spp. in foods. Currently, there is no standard procedure to recover acinetobacters from food in order to gain insight into the food-related ecology and epidemiology of acinetobacters. This study aimed to assess whether enrichment in Dijkshoorn enrichment medium followed by plating in CHROMagar™ Acinetobacter medium is a useful method for the isolation of Acinetobacter spp. from foods. Recovery of six Acinetobacter species from food spiked with these organisms was compared for two selective enrichment media (Baumann's enrichment and Dijkshoorn's enrichment). Significantly (p < 0.01) higher cell counts were obtained in Dijkshoorn's enrichment. Next, the Dijkshoorn's enrichment followed by direct plating on CHROMagar™ Acinetobacter was applied to detect Acinetobacter spp. in different foods. Fourteen different presumptive acinetobacters were recovered and assumed to represent nine different strains on the basis of REP-PCR typing. Eight of these strains were identified by rpoB gene analysis as belonging to the species Acinetobacter johnsonii, Acinetobacter calcoaceticus, Acinetobacter guillouiae and Acinetobacter gandensis. It was not possible to identify the species level of one strain which may suggests that it represents a distinct species. Copyright © 2015 Elsevier Ltd. All rights reserved.
System for analysis of explosives
Haas, Jeffrey S [San Ramon, CA
2010-06-29
A system for analysis of explosives. Samples are spotted on a thin layer chromatography plate. Multi-component explosives standards are spotted on the thin layer chromatography plate. The thin layer chromatography plate is dipped in a solvent mixture and chromatography is allowed to proceed. The thin layer chromatography plate is dipped in reagent 1. The thin layer chromatography plate is heated. The thin layer chromatography plate is dipped in reagent 2.
Kim, Jung Hyun; Hur, Sun Jin; Yim, Dong Gyun
2018-04-01
This research was to evaluate microbial contamination levels in meat samples at hazard analysis critical control point (HACCP)-implemented processing plants that produce beef, pork, and chicken. During a period of about a year, a total of 178 samples (76 from beef, 89 from pork, and 13 from chicken) were obtained from raw materials (21.3%) and final products (78.7%). All samples were determined for each 25 g homogenized one. Samples were analyzed to determine the total aerobic plate count (APC), coliform count (CC), and E. coli count (ECC). By month, APC levels were the highest in September and the lowest in February ( p <0.001). In comparison among season, APC levels in meat samples were the highest in the summer and the lowest in winter ( p <0.001). By month, the highest CC prevalence was found in August, followed by October and then July ( p <0.001). By season, the highest CC was obtained in summer, followed by autumn and then spring ( p <0.001). All samples were negative for ECC. There was a direct correlation between the product form and coliform presence ( p <0.001). In addition, there was a positive correlation between the APC and CC (r=0.261). The APCs in analyzed samples ranged from below <10 1 CFU/g to <10 7 CFU/g. In conclusion, the month and season had significant effects on microbial contamination levels at HACCP implemented processing plants. Interrelationships between (i) the product form and coliform, (ii) the APC and CC were revealed.
NASA Technical Reports Server (NTRS)
Lee, Dana W
1933-01-01
The atomization and distribution characteristics of fuel sprays from automatic injection valves for compression-ignition engines were determined by catching the fuel drops on smoked-glass plates, and then measuring and counting the impressions made in the lampblack. The experiments were made in an air-tight chamber in which the air density was raised to values corresponding to engine conditions.
Shakya, S; Pradhan, B; Smith, L; Shrestha, J; Tuladhar, S
2012-03-01
Arsenic (As) contamination of groundwater is a serious Environmental Health Management issue of drinking water sources especially in Terai region of Nepal. Many studies have reported that due to natural abundance of arsenic in the environment, various bacteria have developed different resistance mechanisms for arsenic compound. In this study, the culturable arsenic-resistant bacteria indigenous to surfacewater as well as groundwater from Rautahat District of Nepal were randomly isolated by standard plate count method on the basis of viable growth on plate count agar amended with arsenate ranging from 0, 0.5, 10, 40, 80 to 160 milligram per liter (mg/l). With respect to the morphological and biochemical tests, nine morphologically distinct potent arsenate tolerant bacteria showed relatedness with Micrococcus varians, Micrococcus roseus, Micrococcus luteus, Pseudomonas maltophilia, Pseudomonas sp., Vibrio parahaemolyticus, Bacillus cereus, Bacillus smithii 1 and Bacillus smithii 2. The isolates were capable of tolerating more than 1000 mg/l of arsenate and 749 mg/l of arsenite. Likewise, bioaccumulation capability was highest with M. roseus (85.61%) and the least with B. smithii (47.88%) indicating the potential of the organisms in arsenic resistance and most probably in bioremediation. Copyright © 2011 Elsevier Ltd. All rights reserved.
Cengiz, M; Sahinturk, P; Sonal, S; Buyukcangaz, E; Sen, A; Arslan, E
2013-05-04
The objective of this work was to investigate the bactericidal activity of enrofloxacin against gyrA mutant and qnr-containing Escherichia coli isolates from animals. The minimum inhibitory concentrations (MICs) of gyrA mutant and qnr-containing E coli isolates ranged from 1 µg/ml to 32 µg/ml for enrofloxacin. Time-kill experiments were performed using selected E coli isolates. For the time-kill experiments, the colony counts were determined by plating each diluted sample onto plate count agar and an integrated pharmacokinetic/pharmacodynamics area measure (log ratio area) was applied to the colony-forming units (cfu) data. In general, enrofloxacin exhibited bactericidal activity against all the gyrA mutant E coli isolates at all concentrations greater than four times the MIC. However, the bactericidal activity of enrofloxacin for all the qnr-containing E coli isolates was less dependent on concentration. The results of the present study indicated that the genetic mechanism of resistance might account for the different bactericidal activities of enrofloxacin observed for the gyrA mutant and the qnr-containing E coli isolates. Therefore, in addition to MIC assays, genetic mechanism-based pharmacodynamic models should be used to provide accurate predictions of the effects of drugs on resistant bacteria.
Funsten, Herbert O.; Harper, Ronnie W.; Dors, Eric E.; ...
2015-10-02
Channel electron multiplier (CEM) and microchannel plate (MCP) detectors are routinely used in space instrumentation for measurement of space plasmas. Here, our goal is to understand the relative sensitivities of these detectors to penetrating radiation in space, which can generate background counts and shorten detector lifetime. We use 662 keV γ-rays as a proxy for penetrating radiation such as γ-rays, cosmic rays, and high-energy electrons and protons that are ubiquitous in the space environment. We find that MCP detectors are ~20 times more sensitive to 662 keV γ-rays than CEM detectors. This is attributed to the larger total area ofmore » multiplication channels in an MCP detector that is sensitive to electronic excitation and ionization resulting from the interaction of penetrating radiation with the detector material. In contrast to the CEM detector, whose quantum efficiency ε γ for 662 keVγ -rays is found to be 0.00175 and largely independent of detector bias, the quantum efficiency of the MCP detector is strongly dependent on the detector bias, with a power law index of 5.5. Lastly, background counts in MCP detectors from penetrating radiation can be reduced using MCP geometries with higher pitch and smaller channel diameter.« less
Quality characteristic of liquid smoked straw mushroom (Volvariella volvacea) ball during storage
NASA Astrophysics Data System (ADS)
Kurniawan, C. W.; Atmaka, W.; Manuhara, G. J.; Sanjaya, A. P.
2018-01-01
Straw mushroom (Volvariella volvacea) ball was soaked for 15, 30, and 45 minutes with the concentration level 1%, 2%, and 3% (v/v) of the coconut shell liquid smoke. The chemical characteristics (water contains, total phenol, carbonil contains, total-N, TVB-N, and pH), microbiological characteristics (Total Plate Count), and sensory characteristics (color, flavor, taste, texture, and overalls) of the liquid smoked straw mushroom ball during 14 days storage at freezing temperature were investigated. The result showed that the water content and TVB-N were decreased after soaked and were increased after storaged. On the other hand, the result of total phenol, carbonyl content, and Total-N were increased after soaked and were decreased after storage. The level of pH and Total Plate Count of the straw mushroom ball were decreased during storage. Due to the sensory characteristics of the straw mushroom ball, the panelists provide high values for the straw mushroom ball which was soaked in 3% concentration level with 30 minutes soaked time. The best-soaked treatment was by soaked at 30 minutes with 3% concentration level liquid smoke. The straw mushroom ball has 70.95±0.10% water contains; 0.32±0.02% total phenol; 1.08±0.22% carbonyl contains; and 2.29±0.07% total-N.
Limitations in the use of ozone to disinfect maple sap.
Labbe, R G; Kinsley, M; Wu, J
2001-01-01
The sap of the maple sugar tree (Acer saccharum) contains 2 to 3% sucrose and is traditionally collected early in the year and concentrated by boiling to produce maple syrup. High levels of microorganisms in the sap occur during holding, leading to a darker syrup with lower economic value. We investigated the use of dissolved ozone as a method to reduce the microbial population in sap. After 40 min of ozone treatment, concentrations of up to 0.30 mg/liter were achieved but were ineffective in reducing the aerobic plate count. Three predominant colonies on nutrient agar were selected for isolation and identification from sap. These included one mucoid and one nonmucoid yeast, both identified as Candida, and Pseudomonas fluorescens. When suspended in buffer, each was readily inactivated by ozone. Addition of 3% sucrose to the buffer markedly reduced the effectiveness of ozone. With the use of an ozone generator with a larger ozone output, saturating ozone concentrations (1 mg/liter) were achieved within 5 min but were accompanied by only a 1-log reduction in aerobic plate count of maple sap. After 40 min of ozone treatment, a less than 3-log reduction occurred. The results indicate that, because of the presence of sucrose, ozone may be of limited use in reducing the microbial population in sap.
Pesewu, George A; Bentum, Daniel; Olu-Taiwo, Michael A; Glover, Kathreen K; Yirenya-Tawiah, Dzidzo R
2017-01-01
Many developing countries, including Ghana, are water stressed. As such, farmers, particularly those in urban areas, have adopted the use of wastewater for irrigation. This study evaluated the bacteriological water quality of the wastewater used for irrigation in the vegetable farms at Korle-Bu Teaching Hospital (KBTH), Accra Metropolis, Ghana. In all, 40 wastewater samples were collected and analysed bacteriologically using the total aerobic plate count method. The isolated bacteria were identified biochemically using Bergey's manual for determinative bacteriology. Mean total bacterial colony count values in the range of 2.75-4.44 × 10 5 CFU/100 mL were isolated which far exceeds values of 1 × 10 3 /100 mL recommended by the World Health Organization (WHO) for unrestricted irrigation of crops likely to be eaten raw. Enterobacter cloacae (51.4%), Klebsiella sp. (24.1%), Pseudomonas aeruginosa (11.3%), Salmonella typhi (10.6%), Escherichia coli (2.2%) and Proteus sp. (0.4%) were the predominant bacteria isolated. Growers should use treated wastewater for farming while processors and consumers should minimize contamination risks of produce from the vegetable farms/garden to the plate. © The Author(s) 2016.
Blood cell counting and classification by nonflowing laser light scattering method
NASA Astrophysics Data System (ADS)
Yang, Ye; Zhang, Zhenxi; Yang, Xinhui; Jiang, Dazong; Yeo, Joon Hock
1999-11-01
A new non-flowing laser light scattering method for counting and classifying blood cells is presented. A linear charge- coupled device with 1024 elements is used to detect the scattered light intensity distribution of the blood cells. A pinhole plate is combined with the CCD to compete the focusing of the measurement system. An isotropic sphere is used to simulate the blood cell. Mie theory is used to describe the scattering of blood cells. In order to inverse the size distribution of blood cells from their scattered light intensity distribution, Powell method combined with precision punishment method is used as a dependent model method for measurement red blood cells and blood plates. Non-negative constraint least square method combined with Powell method and precision punishment method is used as an independent model for measuring white blood cells. The size distributions of white blood cells and red blood cells, and the mean diameter of red blood cells are measured by this method. White blood cells can be divided into three classes: lymphocytes, middle-sized cells and neutrocytes according to their sizes. And the number of blood cells in unit volume can also be measured by the linear dependence of blood cells concentration on scattered light intensity.
NASA Astrophysics Data System (ADS)
Araújo, M. M.; Duarte, R. C.; Silva, P. V.; Marchioni, E.; Villavicencio, A. L. C. H.
2009-07-01
Marketing of minimally processed vegetables (MPV) are gaining impetus due to its convenience, freshness and apparent health effect. However, minimal processing does not reduce pathogenic microorganisms to safe levels. Food irradiation is used to extend the shelf life and to inactivate food-borne pathogens. In combination with minimal processing it could improve safety and quality of MPV. A microbiological screening method based on the use of direct epifluorescent filter technique (DEFT) and aerobic plate count (APC) has been established for the detection of irradiated foodstuffs. The aim of this study was to evaluate the applicability of this technique in detecting MPV irradiation. Samples from retail markets were irradiated with 0.5 and 1.0 kGy using a 60Co facility. In general, with a dose increment, DEFT counts remained similar independent of the irradiation while APC counts decreased gradually. The difference of the two counts gradually increased with dose increment in all samples. It could be suggested that a DEFT/APC difference over 2.0 log would be a criteria to judge if a MPV was treated by irradiation. The DEFT/APC method could be used satisfactorily as a screening method for indicating irradiation processing.
Zhou, Haijian; Wang, Huanxin; Xu, Ying; Zhao, Mingqiang; Guan, Hong; Li, Machao; Shao, Zhujun
2013-01-01
Background Legionella is the causative agent of Legionnaires' disease, and hot springs are a major source of outbreaks of this disease. It is important from a public health perspective to survey hot spring environments for the presence of Legionella. Methods Prospective surveillance of the extent of Legionella pollution was conducted at three hot spring recreational areas in Beijing, China in 2011. Pulsed-field gel electrophoresis (PFGE) and sequence-based typing (SBT) were used to describe the genetic polymorphism of isolates. The intracellular growth ability of the isolates was determined by interacting with J774 cells and plating the dilutions onto BCYE agar plates. Results Overall, 51.9% of spring water samples showed Legionella-positive, and their concentrations ranged from 1 CFU/liter to 2,218 CFU/liter. The positive rates of Legionella were significantly associated with a free chlorine concentration of ≥0.2 mg/L, urea concentration of ≥0.05 mg/L, total microbial counts of ≥400 CFU/ml and total coliform of ≥3 MPN/L (p<0.01). The Legionella concentrations were significantly associated with sample temperature, pH, total microbial counts and total coliform (p<0.01). Legionella pneumophila was the most frequently isolated species (98.9%), and the isolated serogroups included serogroups 3 (25.3%), 6 (23.4%), 5 (19.2%), 1 (18.5%), 2 (10.2%), 8 (0.4%), 10 (0.8%), 9 (1.9%) and 12 (0.4%). Two hundred and twenty-eight isolates were analyzed by PFGE and 62 different patterns were obtained. Fifty-seven L. pneumophila isolates were selected for SBT analysis and divided into 35 different sequence types with 5 main clonal groups. All the 57 isolates had high intracellular growth ability. Conclusions Our results demonstrated high prevalence and genetic polymorphism of Legionella in springs in Beijing, China, and the SBT and intracellular growth assay results suggested that the Legionella isolates of hot spring environments were pathogenic. Improved control and prevention strategies are urgently needed. PMID:23527075
Gu, Xinzhe; Sun, Ye; Tu, Kang; Dong, Qingli; Pan, Leiqing
2016-01-01
A rapid method of predicting the growing situation of Pseudomonas aeruginosa is presented. Gas sensors were used to acquire volatile compounds generated by P. aeruginosa on agar plates and meat stuffs. Then, optimal sensors were selected to simulate P. aeruginosa growth using modified Logistic and Gompertz equations by odor changes. The results showed that the responses of S8 or S10 yielded high coefficients of determination (R2) of 0.89–0.99 and low root mean square errors (RMSE) of 0.06–0.17 for P. aeruginosa growth, fitting the models on the agar plate. The responses of S9, S4 and the first principal component of 10 sensors fit well with the growth of P. aeruginosa inoculated in meat stored at 4 °C and 20 °C, with R2 of 0.73–0.96 and RMSE of 0.25–1.38. The correlation coefficients between the fitting models, as measured by electronic nose responses, and the colony counts of P. aeruginosa were high, ranging from 0.882 to 0.996 for both plate and meat samples. Also, gas chromatography–mass spectrometry results indicated the presence of specific volatiles of P. aeruginosa on agar plates. This work demonstrated an acceptable feasibility of using gas sensors—a rapid, easy and nondestructive method for predicting P. aeruginosa growth. PMID:27941841
van Frankenhuyzen, Jessica K; Trevors, Jack T; Flemming, Cecily A; Lee, Hung; Habash, Marc B
2013-11-01
Biosolids result from treatment of sewage sludge to meet jurisdictional standards, including pathogen reduction. Once government regulations are met, materials can be applied to agricultural lands. Culture-based methods are used to enumerate pathogen indicator microorganisms but may underestimate cell densities, which is partly due to bacteria existing in a viable but non-culturable physiological state. Viable indicators can also be quantified by realtime polymerase chain reaction (qPCR) used with propidium monoazide (PMA), a dye that inhibits amplification of DNA found extracellularly or in dead cells. The objectives of this study were to test an optimized PMA-qPCR method for viable pathogen detection in wastewater solids and to validate it by comparing results to data obtained by conventional plating. Reporter genes from genetically marked Pseudomonas sp. UG14Lr and Agrobacterium tumefaciens 542 cells were spiked into samples of primary sludge, and anaerobically digested and Lystek-treated biosolids as cell-free DNA, dead cells, viable cells, and mixtures of live and dead cells, followed by DNA extraction with and without PMA, and qPCR. The protocol was then used for Escherichia coli quantification in the three matrices, and results compared to plate counts. PMA-qPCR selectively detected viable cells, while inhibiting signals from cell-free DNA and DNA found in membrane-compromised cells. PMA-qPCR detected 0.5-1 log unit more viable E. coli cells in both primary solids and dewatered biosolids than plate counts. No viable E. coli was found in Lystek-treated biosolids. These data suggest PMA-qPCR may more accurately estimate pathogen cell numbers than traditional culture methods.
Thomas, Toby; Gopikrishna, Velayutham; Kandaswamy, Deivanayagam
2008-01-01
The purpose of this study was to evaluate the efficiency of a new storage medium, coconut water, in comparison with other traditional storage media like Hank's balanced salt solution (HBBS) and milk, in maintaining the viability of an established cell line BHK-21/C13 (baby hamster kidney fibroblasts) using the direct suspension cell culture technique. The storage media tested in the study were divided into three major groups and two control groups - Group A: HBBS, Group B: milk, and Group C: coconut water. The positive and negative controls corresponded to 0-minute and 24-hour dry times respectively. The three groups were then divided into five subgroups, each denoting the storage time periods 15 min, 30 min, 45 min, 60 min and 120 min respectively. The cell line BHK-21/C13 was subcultured and the number of cells was standardized by making a cell suspension using Minimal Essential Medium in five culture plates. One ml of each experimental group (HBBS, milk and coconut water) was added to eight wells of each culture plate. The culture plates containing the cells and the experimental groups were incubated for the respective time periods. The cells were then counted with a Neubauer counting chamber, under light microscope. The results were statistically analyzed using One-way ANOVA and Multiple Range Test using the Tukey-HSD procedure to identify the significant groups at p ≤ 0.05. Within the parameters of this study, it appears that coconut water may be a better alternative to HBSS or milk, in terms of maintaining cell viability. Coconut water can be used as a superior transport medium for avulsed teeth. PMID:20142880
Deficits in serum amyloid A contribute to increased neonatal mortality during murine listeriosis.
Hawkins, J Seth; Wu, Qingqing; Wang, Yanxia; Lu, Christopher Y
2013-12-01
To understand the increased susceptibility of preterm neonates to infection. A murine listeriosis model using immunohistochemistry, microarray technology, and real-time polymerase chain reaction (PCR). We report that recombinant serum amyloid A (SAA) administered prophylactically 18 h before intraperitoneal (i.p.) inoculation with Listeria monocytogenes conferred a dramatic survival benefit compared with administration of only vehicle in neonatal mice. Neonates that received the recombinant SAA protein had significantly fewer Listeria colony counts on plating of infected liver and showed significantly more activated macrophages, but SAA did not affect postnatal growth. Real-time PCR was used to confirm the microarray findings that gene expression levels for the SAA proteins 1 (Saa1) and 2 (Saa2), in addition to that for orosomucoid-2 (Orm2), were strikingly elevated in the adult compared with those in the neonate. Real-time PCR analysis showed that of the acute phase cytokines, tumor necrosis factor (TNF) gene expression increased exponentially with time in the infected adult, whereas neonates did not show similar increases. The increased susceptibility of neonatal mice to listeriosis is in part mediated by a deficiency in the acute phase response, specifically expression of SAA, and that prophylactic SAA protein before neonatal murine listeriosis results in more macrophage activation, lower Listeria counts, and greater survival.
Tokajian, Sima T; Hashwa, Fuad A; Hancock, Ian C; Zalloua, Pierre A
2005-04-01
Determination of a heterotrophic plate count (HPC) for drinking-water samples alone is not enough to assess possible health hazards associated with sudden changes in the bacterial count. Speciation is very crucial to determine whether the population includes pathogens and (or) opportunistic pathogens. Most of the isolates recovered from drinking water samples could not be allocated to a specific phylogenetic branch based on the use of conventional diagnostic methods. The present study had to use phylogenetic analysis, which was simplified by determining and using the first 500-bp sequence of the 16S rDNA, to successfully identify the type and species of bacteria found in the samples. Gram-positive bacteria alpha-, beta-, and gamma-Proteobacteria were found to be the major groups representing the heterotrophic bacteria in drinking water. The study also revealed that the presence of sphingomonads in drinking water supplies may be much more common than has been reported so far and thus further studies are merited. The intermittent mode of supply, mainly characterized by water stagnation and flow interruption associated possibly with biofilm detachment, raised the possibility that the studied bacterial populations in such systems represented organisms coming from 2 different niches, the biofilm and the water column.
Sangodoyin, A. Y.
2015-01-01
A box-type solar heater was designed, constructed, and used to determine the effect of solar heating on quality of domestic roof-harvested rainwater (DRHRW). During testing, naturally contaminated DRHRW was harvested in Ibadan, Nigeria, and released into the system at 93.96 Lh−1 (2.61 × 10−5 m3 s−1) in a continuous flow process. Water temperatures at inlet, within the heating chamber, and at outlet from the heating chamber and solar radiation were monitored at 10 min interval. Samples were collected at both inlet to and outlet from the heating chamber at 10 min interval for microbiological analysis. The highest plate stagnation temperature, under no-load condition, was 100°C. The solar water heater attained a maximum operational temperature of 75°C with 89.6 and 94.4% reduction in total viable count and total coliform count, respectively, while Escherichia coli and Staphylococcus aureus were completely eradicated at this temperature. The solar heater developed proved to be effective in enhancing potability of DRHRW in Ibadan, Nigeria. This may be an appropriate household water treatment technology for developing countries, hence, a way of resolving problem of low quality water for potable uses. PMID:27347529
NASA Astrophysics Data System (ADS)
Sun, Da; Xu, Dake; Yang, Chunguang; Shahzad, M. Babar; Sun, Ziqing; Xia, Jin; Zhao, Jinlong; Gu, Tingyue; Yang, Ke; Wang, Guixue
2016-07-01
In order to solve the challenging problem of microbial infections caused by microorganisms on medical implants, it is imperative to develop novel antimicrobial biomaterials. This work demonstrated that 317L-Cu stainless steel (SS), created by adding copper through a solution and aging heat treatment process, exhibited good antibacterial properties against staphylococcus aureus, achieving 2 log reduction of planktonic cells after 5 days of incubation. In this study, the antibacterial test was performed using the plate count method, the fluorescence cell staining method and the quantitative polymerase chain reaction (qPCR) method. It is well known that a high concentration of copper ion can lead to cytotoxicity. This work explored the cytotoxicity of 317L-Cu SS through real-time cell analysis (RTCA). Experimental results demonstrated that the 317L-Cu SS possessed a satisfactory antibacterial ability against S. aureus, and the antibacterial rate based on the reduction of sessile cell count reached 98.3% after 24-hour treatment. The bacterial adhesion and the biofilm thickness were considerably reduced by the 317L-Cu SS. The results of RTCA suggested that 317L-Cu SS did not introduce cytotoxicity to mouse cells, indicating its suitability as a medical implant material.
Akintola, O A; Sangodoyin, A Y
2015-01-01
A box-type solar heater was designed, constructed, and used to determine the effect of solar heating on quality of domestic roof-harvested rainwater (DRHRW). During testing, naturally contaminated DRHRW was harvested in Ibadan, Nigeria, and released into the system at 93.96 Lh(-1) (2.61 × 10(-5) m(3) s(-1)) in a continuous flow process. Water temperatures at inlet, within the heating chamber, and at outlet from the heating chamber and solar radiation were monitored at 10 min interval. Samples were collected at both inlet to and outlet from the heating chamber at 10 min interval for microbiological analysis. The highest plate stagnation temperature, under no-load condition, was 100°C. The solar water heater attained a maximum operational temperature of 75°C with 89.6 and 94.4% reduction in total viable count and total coliform count, respectively, while Escherichia coli and Staphylococcus aureus were completely eradicated at this temperature. The solar heater developed proved to be effective in enhancing potability of DRHRW in Ibadan, Nigeria. This may be an appropriate household water treatment technology for developing countries, hence, a way of resolving problem of low quality water for potable uses.
Stagnari, Fabio; Perpetuini, Giorgia; Tofalo, Rosanna; Campanelli, Gabriele; Leteo, Fabrizio; Della Vella, Umberto; Schirone, Maria; Suzzi, Giovanna; Pisante, Michele
2014-01-01
In the present study, long-term organic and conventional managements were compared at the experimental field of Monsampolo del Tronto (Marche region, Italy) with the aim of investigating soil chemical fertility and microbial community structure. A polyphasic approach, combining soil fertility indicators with microbiological analyses (plate counts, PCR-denaturing gradient gel electrophoresis [DGGE] and phospholipid fatty acid analysis [PLFA]) was applied. Organic matter, N as well as some important macro and micronutrients (K, P, Mg, Mn, Cu, and Zn) for crop growth, were more available under organic management. Bacterial counts were higher in organic management. A significant influence of management system and management x crop interaction was observed for total mesophilic bacteria, nitrogen fixing bacteria and actinobacteria. Interestingly, cultivable fungi were not detected in all analyzed samples. PLFA biomass was higher in the organic and Gram positive bacteria dominated the microbial community in both systems. Even if fungal biomass was higher in organic management, fungal PCR-DGGE fingerprinting revealed that the two systems were very similar in terms of fungal species suggesting that 10 years were not enough to establish a new dynamic equilibrium among ecosystem components. A better knowledge of soil biota and in particular of fungal community structure will be useful for the development of sustainable management strategies. PMID:25540640
Microbial assessment of cabin air quality on commercial airliners
NASA Technical Reports Server (NTRS)
La Duc, Myron T.; Stuecker, Tara; Bearman, Gregory; Venkateswaran, Kasthuri
2005-01-01
The microbial burdens of 69 cabin air samples collected from commercial airliners were assessed via conventional culture-dependent, and molecular-based microbial enumeration assays. Cabin air samples from each of four separate flights aboard two different carriers were collected via air-impingement. Microbial enumeration techniques targeting DNA, ATP, and endotoxin were employed to estimate total microbial burden. The total viable microbial population ranged from 0 to 3.6 x10 4 cells per 100 liters of air, as assessed by the ATP-assay. When these same samples were plated on R2A minimal medium, anywhere from 2% to 80% of these viable populations were cultivable. Five of the 29 samples examined exhibited higher cultivable counts than ATP derived viable counts, perhaps a consequence of the dormant nature (and thus lower concentration of intracellular ATP) of cells inhabiting these air cabin samples. Ribosomal RNA gene sequence analysis showed these samples to consist of a moderately diverse group of bacteria, including human pathogens. Enumeration of ribosomal genes via quantitative-PCR indicated that population densities ranged from 5 x 10 1 ' to IO 7 cells per 100 liters of air. Each of the aforementioned strategies for assessing overall microbial burden has its strengths and weaknesses; this publication serves as a testament to the power of their use in concert.
Comparative calibration of IP scanning equipment
NASA Astrophysics Data System (ADS)
Ingenito, F.; Andreoli, P.; Batani, D.; Boutoux, G.; Cipriani, M.; Consoli, F.; Cristofari, G.; Curcio, A.; De Angelis, R.; Di Giorgio, G.; Ducret, J.; Forestier-Colleoni, P.; Hulin, S.; Jakubowska, K.; Rabhi, N.
2016-05-01
Imaging Plates (IP) are diagnostic devices which contain a photostimulable phosphor layer that stores the incident radiation dose as a latent image. The image is read with a scanner which stimulates the decay of electrons, previously excited by the incident radiation, by exposition to a laser beam. This results in emitted light, which is detected by photomultiplier tubes; so the latent image is reconstructed. IPs have the interesting feature that can be reused many times, after erasing stored information. Algorithms to convert signals stored in the detector to Photostimulated luminescence (PSL) counts depend on the scanner and are not available on every model. A comparative cross-calibration of the IP scanner Dürr CR35 BIO, used in ABC laboratory, was performed, using the Fujifilm FLA 7000 scanner as a reference, to find the equivalence between grey-scale values given by the Dürr scanner to PSL counts. Using an IP and a 55Fe β-source, we produced pairs of samples with the same exposition times, which were analysed by both scanners, placing particular attention to fading times of the image stored on IPs. Data analysis led us to the determine a conversion formula which can be used to compare data of experiments obtained in different laboratories and to use IP calibrations available, till now, only for Fujifilm scanners.
1997-12-05
The following foldout present images and analysis from the Mars Pathfinder Mission that are discussed in seven subsequent Reports. The center is a four-page panorama of the surface of Mars around the lander (Plate 1). The back of the foldout contains surface images (Plate 7), a different perspective of the landing site (Plate 2), rover targets (Plate 3), locations of rocks and other features (Plate 6) and data analysis (Plates 4, 4, 8, 9, and 10).
Buckling behavior of compression-loaded symmetrically-laminated angle-ply plates with holes
NASA Technical Reports Server (NTRS)
Nemeth, M. P.
1986-01-01
An approximate analysis for buckling of a rectangular specially-orthotropic plate with a central circular hole is applied to symmetrically-laminated angle-ply plates. Results obtained from finite element analyses and experiments indicate that the approximate analysis predicts accurately the buckling loads of (+/-theta sub m)s plates with integer values of m not below 6 and with hole diameters up to 50 percent of the plate width. Moreover, the results indicate that the approximate analysis can be used to predict the buckling trends of plates with hole diameters up to 70 percent of the plate width. Results of a parametric study indicate the influence of hole size, plate aspect ratio, loading conditions, boundary conditions, and orthotropy on the buckling load. Results are also presented that indicate the relationship of the bending stiffness and the prebuckling load distribution to the buckling load of a plate with a hole.
Flórez, Ana Belén; Mayo, Baltasar
2015-12-02
This work reports the composition and succession of tetracycline- and erythromycin-resistant bacterial communities in a model cheese, monitored by polymerase chain reaction denaturing gradient gel electrophoresis (PCR-DGGE). Bacterial 16S rRNA genes were examined using this technique to detect structural changes in the cheese microbiota over manufacturing and ripening. Total bacterial genomic DNA, used as a template, was extracted from cultivable bacteria grown without and with tetracycline or erythromycin (both at 25 μg ml(-1)) on a non-selective medium used for enumeration of total and viable cells (Plate Count agar with Milk; PCA-M), and from those grown on selective and/or differential agar media used for counting various bacterial groups; i.e., lactic acid bacteria (de Man, Rogosa and Sharpe agar; MRSA), micrococci and staphylococci (Baird-Parker agar; BPA), and enterobacteria (Violet Red Bile Glucose agar; VRBGA). Large numbers of tetracycline- and erythromycin-resistant bacteria were detected in cheese samples at all stages of ripening. Counts of antibiotic-resistant bacteria varied widely depending on the microbial group and the point of sampling. In general, resistant bacteria were 0.5-1.0 Log10 units fewer in number than the corresponding susceptible bacteria. The PCR-DGGE profiles obtained with DNA isolated from the plates for total bacteria and the different bacterial groups suggested Escherichia coli, Lactococcus lactis, Enterococcus faecalis and Staphylococcus spp. as the microbial types resistant to both antibiotics tested. This study shows the suitability of the PCR-DGGE technique for rapidly identifying and tracking antibiotic resistant populations in cheese and, by extension, in other foods. Copyright © 2015 Elsevier B.V. All rights reserved.
Cruz-Cansino, Nelly Del Socorro; Ramírez-Moreno, Esther; León-Rivera, Jesús Ernesto; Delgado-Olivares, Luis; Alanís-García, Ernesto; Ariza-Ortega, José Alberto; Manríquez-Torres, José de Jesús; Jaramillo-Bustos, Diana Pamela
2015-11-01
The objective of this study was to evaluate changes in color, betalain content, browning index, viscosity, physical stability, microbiological growth, antioxidant content and antioxidant activity of purple cactus pear juice during storage after thermoultrasonication at 80% amplitude level for 15 and 25 min in comparison with pasteurized juice. Thermoultrasound treatment for 25 min increased color stability and viscosity compared to treatment for 15 min (6.83 and 6.72 MPa, respectively), but this last parameter was significantly lower (p<0.05) compared to the control and pasteurized juices (22.47 and 26.32 MPa, respectively). Experimental treatment reduced significantly (p<0.05) sediment solids in juices. Total plate counts decreased from the first day of storage exhibiting values of 1.38 and 1.43 logCFU/mL, for 15 and 25 min treatment, respectively. Compared to the control, both treatments reduced enterobacteria counts (1.54 logCFU/mL), and compared to pasteurized juice decreased pectinmethylesterase activity (3.76 and 3.82 UPE/mL), maintained high values of ascorbic acid (252.05 and 257.18 mg AA/L) and antioxidant activity (by ABTS: 124.8 and 115.6 mg VCEAC/100 mL; and DPPH: 3114.2 and 2757.1 μmol TE/L). During storage thermoultrasonicated juices had a minimum increase in pectinmethylesterase activity (from day 14), and exhibited similar total plate counts to pasteurized juice. An increase of phenolic content was observed after 14 days of storage, particularly for treatment at 80%, 25 min, and an increase in antioxidant activity (ABTS, DPPH) by the end of storage. Copyright © 2015 Elsevier B.V. All rights reserved.
Garcia-Pichel, F.; Johnson, S.L.; Youngkin, D.; Belnap, J.
2003-01-01
We characterized, at millimeter resolution, bacterial biomass, diversity, and vertical stratification of biological soil crusts in arid lands from the Colorado Plateau. Microscopic counts, extractable DNA, and plate counts of viable aerobic copiotrophs (VAC) revealed that the top centimeter of crusted soils contained atypically large bacterial populations, tenfold larger than those in uncrusted, deeper soils. The plate counts were not always consistent with more direct estimates of microbial biomass. Bacterial populations peaked at the immediate subsurface (1-2 mm) in light-appearing, young crusts, and at the surface (0-1 mm) in well-developed, dark crusts, which corresponds to the location of cyanobacterial populations. Bacterial abundance decreased with depth below these horizons. Spatially resolved DGGE fingerprints of Bacterial 16S rRNA genes demonstrated the presence of highly diverse natural communities, but we could detect neither trends with depth in bacterial richness or diversity, nor a difference in diversity indices between crust types. Fingerprints, however, revealed the presence of marked stratification in the structure of the microbial communities, probably a result of vertical gradients in physicochemical parameters. Sequencing and phylogenetic analyses indicated that most of the naturally occurring bacteria are novel types, with low sequence similarity (83-93%) to those available in public databases. DGGE analyses of the VAC populations indicated communities of lower diversity, with most types having sequences more than 94% similar to those in public databases. Our study indicates that soil crusts represent small-scale mantles of fertility in arid ecosystems, harboring vertically structured, little-known bacterial populations that are not well represented by standard cultivation methods.
Modeling of composite beams and plates for static and dynamic analysis
NASA Technical Reports Server (NTRS)
Hodges, Dewey H.; Sutyrin, Vladislav G.; Lee, Bok Woo
1993-01-01
The main purpose of this research was to develop a rigorous theory and corresponding computational algorithms for through-the-thickness analysis of composite plates. This type of analysis is needed in order to find the elastic stiffness constants for a plate and to post-process the resulting plate solution in order to find approximate three-dimensional displacement, strain, and stress distributions throughout the plate. This also requires the development of finite deformation plate equations which are compatible with the through-the-thickness analyses. After about one year's work, we settled on the variational-asymptotical method (VAM) as a suitable framework in which to solve these types of problems. VAM was applied to laminated plates with constant thickness in the work of Atilgan and Hodges. The corresponding geometrically nonlinear global deformation analysis of plates was developed by Hodges, Atilgan, and Danielson. A different application of VAM, along with numerical results, was obtained by Hodges, Lee, and Atilgan. An expanded version of this last paper was submitted for publication in the AIAA Journal.
Shelf life of pasteurized microfiltered milk containing 2% fat.
Caplan, Z; Barbano, D M
2013-01-01
The goal of this research was to produce homogenized milk containing 2% fat with a refrigerated shelf life of 60 to 90 d using minimum high temperature, short time (HTST) pasteurization in combination with other nonthermal processes. Raw skim milk was microfiltered (MF) using a Tetra Alcross MFS-7 pilot plant (Tetra Pak International SA, Pully, Switzerland) equipped with Membralox ceramic membranes (1.4 μm and surface area of 2.31 m(2); Pall Corp., East Hills, NY). The unpasteurized MF skim permeate and each of 3 different cream sources were blended together to achieve three 2% fat milks. Each milk was homogenized (first stage: 17 MPa, second stage: 3 MPa) and HTST pasteurized (73.8°C for 15s). The pasteurized MF skim permeate and the 3 pasteurized homogenized 2% fat milks (made from different fat sources) were stored at 1.7 and 5.7°C and the standard plate count for each milk was determined weekly over 90 d. When the standard plate count was >20,000 cfu/mL, it was considered the end of shelf life for the purpose of this study. Across 4 replicates, a 4.13 log reduction in bacteria was achieved by MF, and a further 0.53 log reduction was achieved by the combination of MF with HTST pasteurization (73.8°C for 15s), resulting in a 4.66 log reduction in bacteria for the combined process. No containers of MF skim milk that was pasteurized after MF exceeded 20,000 cfu/mL bacteria count during 90 d of storage at 5.7°C. The 3 different approaches used to reduce the initial bacteria and spore count of each cream source used to make the 2% fat milks did not produce any shelf-life advantage over using cold separated raw cream when starting with excellent quality raw whole milk (i.e., low bacteria count). The combination of MF with HTST pasteurization (73.8°C for 15s), combined with filling and packaging that was protected from microbial contamination, achieved a refrigerated shelf life of 60 to 90 d at both 1.7 and 5.7°C for 2% fat milks. Copyright © 2013 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
Accurate on line measurements of low fluences of charged particles
NASA Astrophysics Data System (ADS)
Palla, L.; Czelusniak, C.; Taccetti, F.; Carraresi, L.; Castelli, L.; Fedi, M. E.; Giuntini, L.; Maurenzig, P. R.; Sottili, L.; Taccetti, N.
2015-03-01
Ion beams supplied by the 3MV Tandem accelerator of LABEC laboratory (INFN-Firenze), have been used to study the feasibility of irradiating materials with ion fluences reproducible to about 1%. Test measurements have been made with 7.5 MeV 7Li2+ beams of different intensities. The fluence control is based on counting ions contained in short bursts generated by chopping the continuous beam with an electrostatic deflector followed by a couple of adjustable slits. Ions are counted by means of a micro-channel plate (MCP) detecting the electrons emitted from a thin layer of Al inserted along the beam path in between the pulse defining slits and the target. Calibration of the MCP electron detector is obtained by comparison with the response of a Si detector.
Fluoridated elastomers: effect on the microbiology of plaque.
Benson, Philip E; Douglas, C W Ian; Martin, Michael V
2004-09-01
The objective of this study was to investigate the effect of fluoridated elastomeric ligatures on the microbiology of local dental plaque in vivo. This randomized, prospective, longitudinal, clinical trial had a split-mouth crossover design. The subjects were 30 patients at the beginning of their treatment with fixed orthodontic appliances in the orthodontic departments of the Liverpool and the Sheffield dental hospitals in the United Kingdom. The study consisted of 2 experimental periods of 6 weeks with a washout period between. Fluoridated elastomers were randomly allocated at the first visit to be placed around brackets on tooth numbers 12, 11, 33 or 22, 21, 43. Nonfluoridated elastomers were placed on the contralateral teeth. Standard nonantibacterial fluoridated toothpaste and mouthwash were supplied. After 6 weeks (visit 2), the elastomers were removed, placed in transport media, and plated on agar within 2 hours. Nonfluoridated elastomers were placed on all brackets for 1 visit to allow for a washout period. At visit 3, fluoridated elastomers were placed on the teeth contralateral to those that received them at visit 1. At visit 4, the procedures at visit 2 were repeated. Samples were collected on visits 2 and 4. A logistic regression was performed, with the presence or absence of streptococcal or anaerobic growth as the dependent variable. A mixed-effects analysis of variance was carried out with the percentage of streptococcal or anaerobic bacterial count as the dependent variable. The only significant independent variables were the subject variable (P =<.001) for the percentage of streptococcal and anaerobic bacterial count and the visit variable for the percentage of streptococcal count (P =<.001). The use of fluoridated or nonfluoridated elastomers was not significant for percentage of either streptococcal (P =.288) or anaerobic count (P =.230). Fluoridated elastomers are not effective at reducing local streptococcal or anaerobic bacterial growth after a clinically relevant time in the mouth.
de Oliveira Moura, Emmanuella; do Nascimento Rangel, Adriano Henrique; de Melo, Maria Celeste Nunes; Borba, Luiz Henrique Fernandes; de Lima Júnior, Dorgival Morais; Novaes, Luciano Patto; Urbano, Stela Antas; de Andrade Neto, Júlio César
2017-01-01
Objective This study aimed to evaluate the microbiological and cellular milk profile for the diagnosis of subclinical mastitis in female buffaloes and to assess risk factors for predisposition of the disease. Methods Analyses were carried out by standard plate count (SPC), identification of species and antibiotic resistance, somatic cell count (SCC), electrical electrical conductivity of milk (ECM), and lactoferrin content in milk. Teat cups were swabbed to evaluate risk factors, observing hyperkeratosis, milking vacuum pressure and cleanliness of the site. Hence, 30 female buffaloes were randomly selected (15 from a group in early lactation and 15 in late lactation). Results The most common bacteria in the microbiological examination were Staphylococcus spp., Streptococcus spp. and Corynebacterium sp. In the antibiotic sensitivity test, 10 (58.82%) of the 17 antibiotics tested were sensitive to all isolates, and resistant bacteria were Streptococcus uberis, Streptococcus dysgalactiae, Streptococcus haemolyticus, and Escherichia coli. It was observed that positive samples in the microbiological examination showed total bacterial count between 9.10×103 to 6.94×106 colony forming units/mL, SCC between 42,000 to 4,320,000 cells/mL and ECM ranging from 1.85 to 7.40 mS/cm. It was also found that the teat cups had high microbial counts indicating poor hygiene, and even faults in the cleanliness of the animals’ waiting room were observed. It is concluded that values of SCC above 537,000 cells/mL and ECM above 3.0 mS/mL are indications of mammary gland infection for this herd; however, the association of these values with a microbiological analysis is necessary to more accurately evaluate the health status of mammary glands with subclinical mastitis. Conclusion Through phenotypic characterization of bacteria involved in the samples, the genera Staphylococcus spp., Streptococcus spp., and Corynebacterimum bovis were the most prevalent in this study. Faults in environment and equipment hygienization are factors that are directly associated with mastitis. PMID:28183165
Kim, S-J; Kim, D-K; Kang, D-H
2016-04-01
We investigated and compared the efficacy of a new apparatus for detaching micro-organisms from meat samples. The efficacy of Spindle and stomacher in detaching micro-organisms from meat samples was evaluated. Also, evaluation of appropriateness of suspensions generated by both methods for carrying out molecular biological analysis was implemented. A nearly identical correlation and high R(2) were obtained between Spindle and stomacher in Aerobic Plate Count (APC), and no significant differences were observed in detachment of three major foodborne pathogens. The suspension generated by the Spindle showed lower turbidity and total protein concentration. Also, significantly different threshold cycles were observed in Real-time PCR analysis using suspensions generated by both methods. The Spindle shows nearly identical efficacy with stomacher treatment in detaching micro-organisms from meat samples. Furthermore, the high quality of suspensions generated by the Spindle, in terms of turbidity and total protein assay, allows for a lower threshold cycle than stomached suspension in Real-time PCR. The Spindle could be an alternative method for detaching micro-organisms, yielding a higher quality of suspensions which may be better suited for further molecular microbiological analysis. © 2016 The Society for Applied Microbiology.
NASA Astrophysics Data System (ADS)
Silva, A. L. M.; Figueroa, R.; Jaramillo, A.; Carvalho, M. L.; Veloso, J. F. C. A.
2013-08-01
Energy dispersive X-ray fluorescence (EDXRF) imaging systems are of great interest in many applications of different areas, once they allow us to get images of the spatial elemental distribution in the samples. The detector system used in this study is based on a micro patterned gas detector, named Micro-Hole and Strip Plate. The full field of view system, with an active area of 28 × 28 mm2 presents some important features for EDXRF imaging applications, such as a position resolution below 125 μm, an intrinsic energy resolution of about 14% full width at half maximum for 5.9 keV X-rays, and a counting rate capability of 0.5 MHz. In this work, analysis of human teeth treated by dental amalgam was performed by using the EDXRF imaging system mentioned above. The goal of the analysis is to evaluate the system capabilities in the biomedical field by measuring the drift of the major constituents of a dental amalgam, Zn and Hg, throughout the tooth structures. The elemental distribution pattern of these elements obtained during the analysis suggests diffusion of these elements from the amalgam to teeth tissues.
Modeling of composite beams and plates for static and dynamic analysis
NASA Technical Reports Server (NTRS)
Hodges, Dewey H.; Atilgan, Ali R.; Lee, Bok Woo
1990-01-01
A rigorous theory and corresponding computational algorithms was developed for a variety of problems regarding the analysis of composite beams and plates. The modeling approach is intended to be applicable to both static and dynamic analysis of generally anisotropic, nonhomogeneous beams and plates. Development of a theory for analysis of the local deformation of plates was the major focus. Some work was performed on global deformation of beams. Because of the strong parallel between beams and plates, the two were treated together as thin bodies, especially in cases where it will clarify the meaning of certain terminology and the motivation behind certain mathematical operations.
Microcoupon Assay Of Adhesion And Growth Of Bacterial Films
NASA Technical Reports Server (NTRS)
Pierson, Duane L.; Koenig, David W.
1994-01-01
Microbiological assay technique facilitates determination of some characteristics of sessile bacteria like those that attach to and coat interior walls of water-purification systems. Biofilms cause sickness and interfere with purification process. Technique enables direct measurement of rate of attachment of bacterial cells, their metabolism, and effects of chemicals on them. Used to quantify effects of both bactericides and growth-stimulating agents and in place of older standard plate-count and tube-dilution techniques.
Interactions of Liquid Propellant/LP XM46 With Soils
1994-09-01
of the solution was plated for colony counting. Results Microbial populations before contact with I.P (controls) Bacteria were detected in BRL-SAS B...agars ( bacteria ) from the control and short-term contact tests .................... 96 Figure 3 i. Response of microfiora in Picatinny A soil to 1 hr...native actinomycetes, bacteria , and fungi after contact with LP or nmtrin, acid. Effects of washing the soil with water immediately after contact with LP
Microbiological Evaluation of Containment Isolators for the Care of Patients with Exotic Diseases.
1980-02-01
The microbiological integrity of containment isolators obtained from Vickers Limited Medical Engineering was evaluated using aerosols of Tl coliphage ...diluted in sterile distilled water (SDW). Aliquots for plate counts were mixed with log phase host cells and the mixture spread evenly on pre-dried...of water was diffi- cult to maintain and measure accurately even with sensitive meters, and finally visual observation of the curvature of the side
Bacillus Collagen Like Protein of Anthracis: Immunological and Functional Analyses
2007-09-21
heated at 65°C for 30 minutes, diluted, and plated on trypticase soy agar (TSA) to obtain viable counts. Since heat treatment kills the vegetative...purification of that protein by nickel-affinity chromatography are also described in detail elsewhere (Brahmbhatt T.N, lK. Janes, E.S. Stibitz, S.C...Trap Nickel affinity column chromatography with the Fast Phase Liquid Chromatography (FPLC) AKTA system (GE Healthcare, Piscataway, NJ). Rabbit anti
Radiation Resistance of Asporogenous Bacteria in Frozen Beef
1976-03-01
Salmonella enteritidis , and Escherichia coli were used. Cultures were grown to the maximum stationary phase for use as an inoculum. Ground beef containing...eosin methylene blue agar, Shigella- Salmonella agar, and growth on plate count agar with 2.5% and 6.5% NaCl was observed. Penicillin susceptibility was...selective media as follows: Staphylococcus Medium No. 110 for S. aureus; Violet Red Bile Agar for E. coli; and Bismuth Sulfite Agar for S. enteritidis
A Study on the Saving Method of Plate Jigs in Hull Block Butt Welding
NASA Astrophysics Data System (ADS)
Ko, Dae-Eun
2017-11-01
A large amount of plate jigs is used for alignment of welding line and control of welding deformations in hull block assembly stage. Besides material cost, the huge working man-hours required for working process of plate jigs is one of the obstacles in productivity growth of shipyard. In this study, analysis method was proposed to simulate the welding deformations of block butt joint with plate jigs setting. Using the proposed analysis method, an example simulation was performed for actual panel block joint to investigate the saving method of plate jigs. Results show that it is possible to achieve two objectives of quality accuracy of the hull block and saving the plate jig usage at the same time by deploying the plate jigs at the right places. And the proposed analysis method can be used in establishing guidelines for the proper use of plate jigs in block assembly stage.
NASA Astrophysics Data System (ADS)
Katili, Irwan
1993-06-01
A new three-node nine-degree-of-freedom triangular plate bending element is proposed which is valid for the analysis of both thick and thin plates. The element, called the discrete Kirchhoff-Mindlin triangle (DKMT), has a proper rank, passes the patch test for thin and thick plates in an arbitrary mesh, and is free of shear locking. As an extension of the DKMT element, a four-node element with 3 degrees of freedom per node is developed. The element, referred to as DKMQ (discrete Kirchhoff-Mindlin quadrilateral) is found to provide good results for both thin and thick plates without any compatibility problems.
Fuel Cell Thermal Management Through Conductive Cooling Plates
NASA Technical Reports Server (NTRS)
Colozza, Anthony J.; Burke, Kenneth A.
2008-01-01
An analysis was performed to evaluate the concept of utilizing conductive cooling plates to remove heat from a fuel cell stack, as opposed to a conventional internal cooling loop. The potential advantages of this type of cooling system are reduced stack complexity and weight and increased reliability through the reduction of the number of internal fluid seals. The conductive cooling plates would extract heat from the stack transferring it to an external coolant loop. The analysis was performed to determine the required thickness of these plates. The analysis was based on an energy balance between the thermal energy produced within the stack and the heat removal from the cooling plates. To accomplish the energy balance, the heat flow into and along the plates to the cooling fluid was modeled. Results were generated for various numbers of cells being cooled by a single cooling plate. The results provided cooling plate thickness, mass, and operating temperature of the plates. It was determined that utilizing high-conductivity pyrolitic graphite cooling plates can provide a specific cooling capacity (W/kg) equivalent to or potentially greater than a conventional internal cooling loop system.
Matsuura, Yusuke; Kuniyoshi, Kazuki; Suzuki, Takane; Ogawa, Yasufumi; Sukegawa, Koji; Rokkaku, Tomoyuki; Thoreson, Andrew Ryan; An, Kai-Nan; Takahashi, Kazuhisa
2015-01-01
The feasibility of a user-specific finite element model for predicting the in situ strength of the radius after implantation of bone plates for open fracture reduction was established. The effect of metal artifact in CT imaging was characterized. The results were verified against biomechanical test data. Fourteen cadaveric radii were divided into two groups: (1) intact radii for evaluating the accuracy of radial diaphysis strength predictions with finite element analysis and (2) radii with a locking plate affixed for evaluating metal artifact. All bones were imaged with CT. In the plated group, radii were first imaged with the plates affixed (for simulating digital plate removal). They were then subsequently imaged with the locking plates and screws removed (actual plate removal). Fracture strength of the radius diaphysis under axial compression was predicted with a three-dimensional, specimen-specific, nonlinear finite element analysis for both the intact and plated bones (bones with and without the plate captured in the scan). Specimens were then loaded to failure using a universal testing machine to verify the actual fracture load. In the intact group, the physical and predicted fracture loads were strongly correlated. For radii with plates affixed, the physical and predicted (simulated plate removal and actual plate removal) fracture loads were strongly correlated. This study demonstrates that our specimen-specific finite element analysis can accurately predict the strength of the radial diaphysis. The metal artifact from CT imaging was shown to produce an overestimate of strength.
Antimicrobial and physical properties of chitosan films incorporated with turmeric extract.
Kalaycıoğlu, Zeynep; Torlak, Emrah; Akın-Evingür, Gülşen; Özen, İlhan; Erim, F Bedia
2017-08-01
In this study, the effects of turmeric extract incorporation on the antibacterial and physical properties of the chitosan films were evaluated. Turmeric containing chitosan-based film was produced with casting procedure and cross-linked with sodium sulfate. Mechanical, optical, thermal properties, and water vapor permeability of the films were studied. The addition of turmeric to chitosan film significantly increased the tensile strength of the film and improved the ultraviolet-visible light barrier of the film. Infrared spectroscopy analysis suggested an interaction between the phenolic compounds of the extract and amin group of chitosan. Antimicrobial activity of the chitosan films was studied against Salmonella and Staphylococcus aureus by plate count agar technique and a better antimicrobial activity was observed with turmeric incorporation. Turmeric incorporated chitosan films with enhanced antimicrobial activity and film stiffness can be suggested as a promising application for food packaging. Copyright © 2017 Elsevier B.V. All rights reserved.
Silva, Nádia F D; Magalhães, Júlia M C S; Freire, Cristina; Delerue-Matos, Cristina
2018-01-15
According to the recent statistics, Salmonella is still an important public health issue in the whole world. Legislated reference methods, based on counting plate methods, are sensitive enough but are inadequate as an effective emergency response tool, and are far from a rapid device, simple to use out of lab. An overview of the commercially available rapid methods for Salmonella detection is provided along with a critical discussion of their limitations, benefits and potential use in a real context. The distinguished potentialities of electrochemical biosensors for the development of rapid devices are highlighted. The state-of-art and the newest technologic approaches in electrochemical biosensors for Salmonella detection are presented and a critical analysis of the literature is made in an attempt to identify the current challenges towards a complete solution for Salmonella detection in microbial food control based on electrochemical biosensors. Copyright © 2017 Elsevier B.V. All rights reserved.
Van der Merwe, Maretha; Hoffman, Louw C; Jooste, Piet J; Calitz, Frikkie Johannes
2013-05-01
Three game meat production systems used on game ranches in South Africa are reported on. System one is applied in the game export market and conforms to the hygiene requirements of the European Union (EU). System two and three entail game meat available on the local market not subjected to any regulation. System 2 however, implemented basic meat hygiene values. Measurements of pH, temperature, Aerobic Plate Count (APC), E. coli, Salmonella and S. aureus were subjected to a 3×2 factorial analysis of variance with factors that involve 3 system compliances in 2 classes of game animals in a completely randomised design. The measured bacteriological and quality differences between the three systems do not justify EU standards application on the local market but results indicated a significant compliance×class interaction. Copyright © 2013 Elsevier Ltd. All rights reserved.
NASA Technical Reports Server (NTRS)
Pyle, B. H.; Broadaway, S. C.; McFeters, G. A.
1999-01-01
Rapid, direct methods are needed to assess active bacterial populations in water and foods. Our objective was to determine the efficiency of bacterial detection by immunomagnetic separation (IMS) and the compatibility of IMS with cyanoditolyl tetrazolium chloride (CTC) incubation to determine respiratory activity, using the pathogen Escherichia coli O157:H7. Counterstaining with a specific fluorescein-conjugated anti-O157 antibody (FAb) following CTC incubation was used to allow confirmation and visualization of bacteria by epifluorescence microscopy. Broth-grown E. coli O157:H7 was used to inoculate fresh ground beef (<17% fat), sterile 0.1% peptone, or water. Inoculated meat was diluted and homogenized in a stomacher and then incubated with paramagnetic beads coated with anti-O157 specific antibody. After IMS, cells with magnetic beads attached were stained with CTC and then an anti-O157 antibody-fluorescein isothiocyanate conjugate and filtered for microscopic enumeration or solid-phase laser cytometry. Enumeration by laser scanning permitted detection of ca. 10 CFU/g of ground beef or <10 CFU/ml of liquid sample. With inoculated meat, the regression results for log-transformed respiring FAb-positive counts of cells recovered on beads versus sorbitol-negative plate counts in the inoculum were as follows: intercept = 1.06, slope = 0.89, and r2 = 0. 95 (n = 13). The corresponding results for inoculated peptone were as follows: intercept = 0.67, slope = 0.88, and r2 = 0.98 (n = 24). Recovery of target bacteria on beads by the IMS-CTC-FAb method, compared with recovery by sorbitol MacConkey agar plating, yielded greater numbers (beef, 6.0 times; peptone, 3.0 times; water, 2.4 times). Thus, within 5 to 7 h, the IMS-CTC-FAb method detected greater numbers of E. coli O157 cells than were detected by plating. The results show that the IMS-CTC-FAb technique with enumeration by either fluorescence microscopy or solid-phase laser scanning cytometry gave results that compared favorably with plating following IMS.
Morgan, S M; Hickey, R; Ross, R P; Hill, C
2000-07-01
A novel method for the isolation of microbially-derived inhibitory substances from food sources was developed. The method involves an enrichment step coupled to a killing assay which is initially carried out in multiwell plates. The technique has advantages in that large numbers of samples can be tested in parallel. The assay can be completed in less than 60 h and is more sensitive than direct plating due to the enrichment step. This novel screening approach was compared with the standard direct plating approach in an effort to identify the antimicrobial potential of a number of Kefir grains. Kefir grains were incubated in 10% reconstituted skim milk for 20 h at 32 degrees C to enable production of any potential biopreservatives. Following overnight incubation, fermentates were aliquoted into multi-well plates and a known number of indicator cells was added to each well. The fermentates were incubated for a further 20 h and counts were carried out to determine whether a reduction in indicator cell numbers had occurred. A reduction in cell-forming units indicated the presence of an inhibitory substance and these inhibitory fermentates were selected for further investigation. Using the protocol outlined, Kefir fermentates capable of inhibiting Listeria innocua DPC1770 and Escherichia coli O157:H45 were identified.
Addison, Elena S; Clements, Dylan N
2017-12-01
Objectives The aim of this study was to evaluate the repeatability of quantitative sensory tests (QSTs) in a group of healthy untrained cats (n = 14) and to compare the results with those from cats with osteoarthritis (n = 7). Methods Peak vertical force (PVF) and vertical impulse were measured on a pressure plate system. Thermal sensitivity was assessed using a temperature-controlled plate at 7°C and 40°C. Individual paw lifts and overall duration of paw lifts were counted and measured for each limb. Paw withdrawal thresholds were measured using manual and electronic von Frey monofilaments (MVF and EVF, respectively) applied to the metacarpal or metatarsal pads. All measurements were repeated twice to assess repeatability of the tests. Results In healthy cats all tests were moderately repeatable. When compared with cats with osteoarthritis the PVF was significantly higher in healthy hindlimbs in repeat 1 but not in repeat 2. Cats with osteoarthritis of the forelimbs showed a decrease in the frequency of paw lifts on the 7°C plate compared with cats with healthy forelimbs, and the duration of paw lifts was significantly less than healthy forelimbs in the first repeat but not in the second repeat. Osteoarthritic limbs had significantly lower paw withdrawal thresholds with both MVF and EVF than healthy limbs. Conclusions and relevance QSTs are moderately repeatable in untrained cats. Kinetic gait analysis did not permit differentiation between healthy limbs and those with osteoarthritis, but thermal sensitivity testing (cold) does. Sensory threshold testing can differentiate osteoarthritic and healthy limbs, and may be useful in the diagnosis and monitoring of this condition in cats in the clinical setting.
Effect of selected solutes on growth and recovery of a radiation-resistant Moraxella
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bruns, M.A.; Maxcy, R.B.
1978-01-01
A highly radiation-resistant Moraxella sp. from beef was more resistant to gamma radiation in frozen beef than Clostridium botulinum 33A spores. Even though the Moraxella sp. was extremely radiation-resistant, its recovery after irradiation was markedly influenced by the plating medium. Fewer colony-forming units were recovered in Tryptic Soy Agar (TSA) than in Plate Count Agar (PCA), and differences in recovery became more pronounced with increasing radiation dose. Growth studies of the nonirradiated Moraxella sp. suggested the presence of dialyzable inhibitory factor(s) in Trypticase Soy Broth (TSB) and TSA. The low (0.5 percent) concentration of NaCl in TSA was shown tomore » be mainly responsible for the slow growth and reduced recovery after irradiation. Reduced recovery was also obtained by plating the Moraxella sp. in PCA plus 0.5 percent NaCl or PCA plus 6 percent glucose after irradiation. It was noted that 2 other highly radiation-resistant isolates identified as Moraxella sp. gave similar results. Sensitivity to low solute concentrations, therefore, appeared to be a general phenomenon for this group.« less
Killing rate of colony count by hydrodynamic cavitation due to square multi-orifice plates
NASA Astrophysics Data System (ADS)
Dong, Zhiyong; Zhao, Wenqian
2018-02-01
Currently,in water supply engineering, the conventional technique of disinfection by chlorination is employed to kill pathogenic microorganisms in raw water. However, chlorine reacts with organic compounds in water and generates disinfection byproducts (DBPs), such as trihalomethanes (THMs), haloacetic acids (HAAs) etc. These byproducts are of carcinogenic, teratogenic and mutagenic effects, which seriously threaten human health. Hydrodynamic cavitation is a novel technique of drinking water disinfection without DBPs. Effects of orifice size, orifice number and orifice layout of multi-orifice plate, cavitation number, cavitation time and orifice velocity on killing pathogenic microorganisms by cavitation were investigated experimentally in a self-developed square multi-orifice plate-type hydrodynamic cavitation device. The experimental results showed that cavitation effects increased with decrease in orifice size and increase in orifice number, cavitation time and orifice velocity. Along with lowering in cavitation number, there was an increase in Reynolds shear stress,thus enhancing the killing rate of pathogenic microorganism in raw water. In addition, the killing rate by staggered orifice layout was greater than that by checkerboard-type orifice layout.
Luppens, S B; Abee, T; Oosterom, J
2001-04-01
The difference in killing exponential- and stationary-phase cells of Listeria monocytogenes by benzalkonium chloride (BAC) was investigated by plate counting and linked to relevant bioenergetic parameters. At a low concentration of BAC (8 mg liter(-1)), a similar reduction in viable cell numbers was observed for stationary-phase cells and exponential-phase cells (an approximately 0.22-log unit reduction), although their membrane potential and pH gradient were dissipated. However, at higher concentrations of BAC, exponential-phase cells were more susceptible than stationary-phase cells. At 25 mg liter(-1), the difference in survival on plates was more than 3 log units. For both types of cells, killing, i.e., more than 1-log unit reduction in survival on plates, coincided with complete inhibition of acidification and respiration and total depletion of ATP pools. Killing efficiency was not influenced by the presence of glucose, brain heart infusion medium, or oxygen. Our results suggest that growth phase is one of the major factors that determine the susceptibility of L. monocytogenes to BAC.
NASA Technical Reports Server (NTRS)
Mayers, J; Budiansky, Bernard
1955-01-01
An analysis is presented of the postbuckling behavior of a simply supported square flat plate with straight edges compressed beyond the buckling load into the plastic range. The method of analysis involves the application of a variational principle of the deformation theory of plasticity in conjunction with computations carried out on a high-speed calculating machine. Numerical results are obtained for several plate proportions and for one material. The results indicate plate strengths greater than those that have been found experimentally on plates that do not satisfy straight-edge conditions. (author)
Shih, Cheng-Min; Huang, Kui-Chou; Pan, Chien-Chou; Lee, Cheng-Hung; Su, Kuo-Chih
2015-11-01
Clavicle hook plates are frequently used in clinical orthopaedics to treat acromioclavicular joint dislocation. However, patients often exhibit acromion osteolysis and per-implant fracture after undergoing hook plate fixation. With the intent of avoiding future complications or fixation failure after clavicle hook plate fixation, we used finite element analysis (FEA) to investigate the biomechanics of clavicle hook plates of different materials and sizes when used in treating acromioclavicular joint dislocation. Using finite element analysis, this study constructed a model comprising four parts: clavicle, acromion, clavicle hook plate and screws, and used the model to simulate implanting different types of clavicle hook plates in patients with acromioclavicular joint dislocation. Then, the biomechanics of stainless steel and titanium alloy clavicle hook plates containing either six or eight screw holes were investigated. The results indicated that using a longer clavicle hook plate decreased the stress value in the clavicle, and mitigated the force that clavicle hook plates exert on the acromion. Using a clavicle hook plate material characterized by a smaller Young's modulus caused a slight increase in the stress on the clavicle. However, the external force the material imposed on the acromion was less than the force exerted on the clavicle. The findings of this study can serve as a reference to help orthopaedic surgeons select clavicle hook plates.
Symmetries in laminated composite plates
NASA Technical Reports Server (NTRS)
Noor, A. K.
1976-01-01
The different types of symmetry exhibited by laminated anisotropic fibrous composite plates are identified and contrasted with the symmetries of isotropic and homogeneous orthotropic plates. The effects of variations in the fiber orientation and the stacking sequence of the layers on the symmetries exhibited by composite plates are discussed. Both the linear and geometrically nonlinear responses of the plates are considered. A simple procedure is presented for exploiting the symmetries in the finite element analysis. Examples are given of square, skew and polygonal plates where use of symmetry concepts can significantly reduce the scope and cost of analysis.
Mansion-de Vries, Elisabeth Maria; Knorr, Nicole; Paduch, Jan-Hendrik; Zinke, Claudia; Hoedemaker, Martina; Krömker, Volker
2014-03-01
Clinical mastitis is one of the most common and expensive diseases of dairy cattle. To make an informed treatment decision, it is important to know the causative pathogen. However, no detection of bacterial growth can be made in approximately 30% of all clinical cases of mastitis. Before selecting the treatment regimen, it is important to know whether the mastitis-causing pathogen (MCP) is Gram-positive or Gram-negative. The aim of this field study was to investigate whether using two 3M Petrifilm™ products on-farm (which conveys a higher degree of sample freshness but also bears a higher risk for contamination than working in a lab) as 24-h rapid diagnostic of clinical mastitis achieved results that were comparable to the conventional microbiological diagnostic method. AerobicCount (AC)-Petrifilm™ and ColiformCount (CC)-Petrifilm™ were used to identify the total bacterial counts and Gram-negative bacteria in samples from clinical mastitis cases, respectively. Missing growth on both plates was classified as no bacterial detection. Growth only on the AC-Petrifilm™ was assessed as Gram-positive, and growth on both Petrifilm™ plates was assessed as Gram-negative bacterial growth. Additionally, milk samples were analysed by conventional microbiological diagnostic method on aesculin blood agar as a reference method. Overall, 616 samples from clinical mastitis cases were analysed. Using the reference method, Gram-positive and Gram-negative bacteria, mixed bacterial growth, contaminated samples and yeast were determined in 32.6%, 20.0%, 2.5%, 14.1% and 1.1% of the samples, respectively. In 29.7% of the samples, microbiological growth could not be identified. Using the Petrifilm™ concept, bacterial growth was detected in 59% of the culture-negative samples. The sensitivity of the Petrifilm™ for Gram-positive and Gram-negative MCP was 85.2% and 89.9%, respectively. The specificity was 75.4% for Gram-positive and 88.4% for Gram-negative MCP. For the culture-negative samples, sensitivity was 41.0% and specificity was 91.0%. The results indicate that the Petrifilm™ concept is suitable for therapeutic decision-making at the farm level or in veterinary practice. As this concept does not allow any statement about the genus or species of microorganisms, relevant MCP should be assessed periodically at the herd level with conventional microbiological diagnostics. Copyright © 2014 Elsevier B.V. All rights reserved.
Dobrowsky, Penelope H; Khan, Sehaam; Cloete, Thomas E; Khan, Wesaal
2016-10-10
Legionella spp. employ multiple strategies to adapt to stressful environments including the proliferation in protective biofilms and the ability to form associations with free-living amoeba (FLA). The aim of the current study was to identify Legionella spp., Acanthamoeba spp., Vermamoeba (Hartmannella) vermiformis and Naegleria fowleri that persist in a harvested rainwater and solar pasteurization treatment system. Pasteurized (45 °C, 65 °C, 68 °C, 74 °C, 84 °C and 93 °C) and unpasteurized tank water samples were screened for Legionella spp. and the heterotrophic plate count was enumerated. Additionally, ethidium monoazide quantitative polymerase chain reaction (EMA-qPCR) was utilized for the quantification of viable Legionella spp., Acanthamoeba spp., V. vermiformis and N. fowleri in pasteurized (68 °C, 74 °C, 84 °C and 93 °C) and unpasteurized tank water samples, respectively. Of the 82 Legionella spp. isolated from unpasteurized tank water samples, Legionella longbeachae (35 %) was the most frequently isolated, followed by Legionella norrlandica (27 %) and Legionella rowbothamii (4 %). Additionally, a positive correlation was recorded between the heterotrophic plate count vs. the number of Legionella spp. detected (ρ = 0.710, P = 0.048) and the heterotrophic plate count vs. the number of Legionella spp. isolated (ρ = 0.779, P = 0.0028) from the tank water samples collected. Solar pasteurization was effective in reducing the gene copies of viable V. vermiformis (3-log) and N. fowleri (5-log) to below the lower limit of detection at temperatures of 68-93 °C and 74-93 °C, respectively. Conversely, while the gene copies of viable Legionella and Acanthamoeba were significantly reduced by 2-logs (P = 0.0024) and 1-log (P = 0.0015) overall, respectively, both organisms were still detected after pasteurization at 93 °C. Results from this study indicate that Acanthamoeba spp. primarily acts as the vector and aids in the survival of Legionella spp. in the solar pasteurized rainwater as both organisms were detected and were viable at high temperatures (68-93 °C).
Theoretical analysis of a ceramic plate thickness-shear mode piezoelectric transformer.
Xu, Limei; Zhang, Ying; Fan, Hui; Hu, Junhui; Yang, Jiashi
2009-03-01
We perform a theoretical analysis on a ceramic plate piezoelectric transformer operating with thickness-shear modes. Mindlin's first-order theory of piezoelectric plates is employed, and a forced vibration solution is obtained. Transforming ratio, resonant frequencies, and vibration mode shapes are calculated, and the effects of plate thickness and electrode dimension are examined.
AE Source Orientation by Plate Wave Analysis
NASA Technical Reports Server (NTRS)
Gorman, Michael R.; Prosser, William H.
1991-01-01
Lead breaks (Hsu-Neilsen source) were used to generate simulated acoustic emission signals in an aluminum plate at angles of 0, 30, 60, and 90 degrees with respect to the plane of the plate. This was accomplished by breaking the lead on slots cut into the plate at the respective angles. The out-of-plane and in-plane displacement components of the resulting signals were detected by broad band transducers and digitized. Analysis of the waveforms showed them to consist of the extensional and flexural plate modes. The amplitude of both components of the two modes was dependent on the source orientation angle. This suggests that plate wave analysis may be used to determine the source orientation of acoustic emission sources.
Disposable bioluminescence-based biosensor for detection of bacterial count in food.
Luo, Jinping; Liu, Xiaohong; Tian, Qing; Yue, Weiwei; Zeng, Jing; Chen, Guangquan; Cai, Xinxia
2009-11-01
A biosensor for rapid detection of bacterial count based on adenosine 5'-triphosphate (ATP) bioluminescence has been developed. The biosensor is composed of a key sensitive element and a photomultiplier tube used as a detector element. The disposable sensitive element consists of a sampler, a cartridge where intracellular ATP is chemically extracted from bacteria, and a microtube where the extracted ATP reacts with the luciferin-luciferase reagent to produce bioluminescence. The bioluminescence signal is transformed into relevant electrical signal by the detector and further measured with a homemade luminometer. Parameters affecting the amount of the extracted ATP, including the types of ATP extractants, the concentrations of ATP extractant, and the relevant neutralizing reagent, were optimized. Under the optimal experimental conditions, the biosensor showed a linear response to standard bacteria in a concentration range from 10(3) to 10(8) colony-forming units (CFU) per milliliter with a correlation coefficient of 0.925 (n=22) within 5min. Moreover, the bacterial count of real food samples obtained by the biosensor correlated well with those by the conventional plate count method. The proposed biosensor, with characteristics of low cost, easy operation, and fast response, provides potential application to rapid evaluation of bacterial contamination in the food industry, environment monitoring, and other fields.
Use of mixed cultures of biocontrol agents to control sheep nematodes.
Baloyi, M A; Laing, M D; Yobo, K S
2012-03-23
Biological control is a promising non-chemical approach for the control of gastrointestinal nematodes of sheep. Use of combinations of biocontrol agents have been reported to be an effective method to increase the efficacy of biological control effects. In this study, combinations of either two Bacillus thuringiensis (Bt) or Clonostachys rosea (C. rosea) isolates and Bt+C. rosea isolates were evaluated in vitro in microtitre plates for their biocontrol activity on sheep nematodes. The Baermann technique was used to extract the surviving L3 larval stages of intestinal nematodes and counted under a dissecting microscope to determine the larval counts. Results indicate that there was a significant reduction of nematode counts due to combination of biocontrol agents (P<0.001). Combinations of Bt isolates reduced nematodes counts by 72.8%, 64% and 29.8%. The results revealed a control level of 57% when C. rosea isolates P3+P8 were combined. Combination of Bt and C. rosea isolates B10+P8 caused the greatest mortality of 76.7%. Most combinations were antagonistic, with only a few combinations showing an additive effect. None were synergistic. The isolate combinations were more effective than when isolates were used alone. Copyright © 2011 Elsevier B.V. All rights reserved.
Computational models for the nonlinear analysis of reinforced concrete plates
NASA Technical Reports Server (NTRS)
Hinton, E.; Rahman, H. H. A.; Huq, M. M.
1980-01-01
A finite element computational model for the nonlinear analysis of reinforced concrete solid, stiffened and cellular plates is briefly outlined. Typically, Mindlin elements are used to model the plates whereas eccentric Timoshenko elements are adopted to represent the beams. The layering technique, common in the analysis of reinforced concrete flexural systems, is incorporated in the model. The proposed model provides an inexpensive and reasonably accurate approach which can be extended for use with voided plates.
Bowling, Frank L; Stickings, Daryl S; Edwards-Jones, Valerie; Armstrong, David G; Boulton, Andrew Jm
2009-05-08
The purpose of this study was to assess the level of air contamination with bacteria after surgical hydrodebridement and to determine the effectiveness of hydro surgery on bacterial reduction of a simulated infected wound. Four porcine samples were scored then infected with a broth culture containing a variety of organisms and incubated at 37 degrees C for 24 hours. The infected samples were then debrided with the hydro surgery tool (Versajet, Smith and Nephew, Largo, Florida, USA). Samples were taken for microbiology, histology and scanning electron microscopy pre-infection, post infection and post debridement. Air bacterial contamination was evaluated before, during and after debridement by using active and passive methods; for active sampling the SAS-Super 90 air sampler was used, for passive sampling settle plates were located at set distances around the clinic room. There was no statistically significant reduction in bacterial contamination of the porcine samples post hydrodebridement. Analysis of the passive sampling showed a significant (p < 0.001) increase in microbial counts post hydrodebridement. Levels ranging from 950 colony forming units per meter cubed (CFUs/m3) to 16780 CFUs/m3 were observed with active sampling of the air whilst using hydro surgery equipment compared with a basal count of 582 CFUs/m3. During removal of the wound dressing, a significant increase was observed relative to basal counts (p < 0.05). Microbial load of the air samples was still significantly raised 1 hour post-therapy. The results suggest a significant increase in bacterial air contamination both by active sampling and passive sampling. We believe that action might be taken to mitigate fallout in the settings in which this technique is used.
Aslanimehr, Masoomeh; Rezvani, Shirin; Mahmoudi, Ali; Moosavi, Najmeh
2017-01-01
Statement of the Problem: Candida species are believed to play an important role in initiation and progression of denture stomatitis. The type of the denture material also influences the adhesion of candida and development of stomatitis. Purpose: The aim of this study was comparing the adherence of candida albicans to the conventional and injection molding acrylic denture base materials. Materials and Method: Twenty injection molding and 20 conventional pressure pack acrylic discs (10×10×2 mm) were prepared according to their manufacturer’s instructions. Immediately before the study, samples were placed in sterile water for 3 days to remove residual monomers. The samples were then sterilized using an ultraviolet light unit for 10 minutes. 1×108 Cfu/ml suspension of candida albicans ATCC-10231 was prepared from 48 h cultured organism on sabouraud dextrose agar plates incubated at 37oC. 100 μL of this suspension was placed on the surface of each disk. After being incubated at 37oC for 1 hour, the samples were washed with normal saline to remove non-adherent cells. Attached cells were counted using the colony count method after shaking at 3000 rmp for 20 seconds. Finally, each group was tested for 108 times and the data were statistically analyzed by t-test. Results: Quantitative analysis revealed that differences in colony count average of candida albicans adherence to conventional acrylic materials (8.3×103) comparing to injection molding acrylic resins (6×103) were statistically significant (p<0.001). Conclusion: Significant reduction of candida albicans adherence to the injection acrylic resin materials makes them valuable for patients with high risk of denture stomatitis. PMID:28280761
Aslanimehr, Masoomeh; Rezvani, Shirin; Mahmoudi, Ali; Moosavi, Najmeh
2017-03-01
Candida species are believed to play an important role in initiation and progression of denture stomatitis. The type of the denture material also influences the adhesion of candida and development of stomatitis. The aim of this study was comparing the adherence of candida albicans to the conventional and injection molding acrylic denture base materials. Twenty injection molding and 20 conventional pressure pack acrylic discs (10×10×2 mm) were prepared according to their manufacturer's instructions. Immediately before the study, samples were placed in sterile water for 3 days to remove residual monomers. The samples were then sterilized using an ultraviolet light unit for 10 minutes. 1×10 8 Cfu/ml suspension of candida albicans ATCC-10231 was prepared from 48 h cultured organism on sabouraud dextrose agar plates incubated at 37oC. 100 μL of this suspension was placed on the surface of each disk. After being incubated at 37oC for 1 hour, the samples were washed with normal saline to remove non-adherent cells. Attached cells were counted using the colony count method after shaking at 3000 rmp for 20 seconds. Finally, each group was tested for 108 times and the data were statistically analyzed by t-test. Quantitative analysis revealed that differences in colony count average of candida albicans adherence to conventional acrylic materials (8.3×10 3 ) comparing to injection molding acrylic resins (6×10 3 ) were statistically significant ( p <0.001). Significant reduction of candida albicans adherence to the injection acrylic resin materials makes them valuable for patients with high risk of denture stomatitis.
Bunthof, Christine J; Abee, Tjakko
2002-06-01
Flow cytometry (FCM) is a rapid and sensitive technique that can determine cell numbers and measure various physiological characteristics of individual cells by using appropriate fluorescent probes. Previously, we developed an FCM assay with the viability probes carboxyfluorescein diacetate (cFDA) and TOTO-1 [1'-(4,4,7,7-tetramethyl-4,7-diazaundecamethylene)-bis-4-[3-methyl-2,3dihydro(benzo-1,3-oxazole)-2-methylidene]-1-(3'-trimethylammoniumpropyl)-pyridinium tetraiodide] for (stressed) lactic acid bacteria (C. J. Bunthof, K. Bloemen, P. Breeuwer, F. M. Rombouts, and T. Abee, Appl. Environ. Microbiol. 67:2326-2335, 2001). cFDA stains intact cells with enzymatic activity, and TOTO-1 stains membrane-permeabilized cells. Here we used this assay to study the viability of bacterial suspensions in milk, dairy fermentation starters, and probiotic products. To facilitate FCM analysis of bacteria in milk, a commercially available milk-clearing solution was used. The procedure was optimized to increase the signal-to-noise ratio. FCM enumerations were accurate down to a concentration of 10(5) cells ml(-1). The level of retrieval of Lactobacillus plantarum WCFS 1 suspended in milk was high, and viability was not affected by the procedure. The plate counts for cleared samples of untreated cell suspensions were nearly as high as the total FCM counts, and the correlation was strong (r > 0.99). In dairy fermentation starters and in probiotic products the FCM total cell counts were substantially higher than the numbers of CFU. Three functional populations could be distinguished: culturable cells, cells that are intact and metabolically active but not culturable, and permeabilized cells. The proportions of the populations differed in the products tested. This FCM method provides tools to assess the functionality of different populations in fermentation starters and probiotic products.
Bunthof, Christine J.; Abee, Tjakko
2002-01-01
Flow cytometry (FCM) is a rapid and sensitive technique that can determine cell numbers and measure various physiological characteristics of individual cells by using appropriate fluorescent probes. Previously, we developed an FCM assay with the viability probes carboxyfluorescein diacetate (cFDA) and TOTO-1 {1′-(4,4,7,7-tetramethyl-4,7-diazaundecamethylene)-bis-4-[3-methyl-2,3dihydro(benzo-1,3-oxazole)-2-methylidene]-1-(3′-trimethylammoniumpropyl)-pyridinium tetraiodide} for (stressed) lactic acid bacteria (C. J. Bunthof, K. Bloemen, P. Breeuwer, F. M. Rombouts, and T. Abee, Appl. Environ. Microbiol. 67:2326-2335, 2001). cFDA stains intact cells with enzymatic activity, and TOTO-1 stains membrane-permeabilized cells. Here we used this assay to study the viability of bacterial suspensions in milk, dairy fermentation starters, and probiotic products. To facilitate FCM analysis of bacteria in milk, a commercially available milk-clearing solution was used. The procedure was optimized to increase the signal-to-noise ratio. FCM enumerations were accurate down to a concentration of 105 cells ml−1. The level of retrieval of Lactobacillus plantarum WCFS 1 suspended in milk was high, and viability was not affected by the procedure. The plate counts for cleared samples of untreated cell suspensions were nearly as high as the total FCM counts, and the correlation was strong (r > 0.99). In dairy fermentation starters and in probiotic products the FCM total cell counts were substantially higher than the numbers of CFU. Three functional populations could be distinguished: culturable cells, cells that are intact and metabolically active but not culturable, and permeabilized cells. The proportions of the populations differed in the products tested. This FCM method provides tools to assess the functionality of different populations in fermentation starters and probiotic products. PMID:12039752
Quantitative analysis of fecal flora in goat kids with and without floppy kid syndrome.
Bleul, U; Fassbind, N; Ghielmetti, G; Zoller, D; Liesegang, A; Hässig, M; Wittenbrink, M M; Prohaska, S
2013-01-01
Floppy kid syndrome (FKS) affects goat kids in the first month of life and is associated with high morbidity and mortality rates. The condition is characterized by neurological signs that can be ascribed to increased plasma D-lactate concentrations. The source of D-lactate has not been identified conclusively, but D-lactate-producing bacteria in the large intestine are thought to be involved. To determine the number of colony-forming unit (CFUs) of certain groups of bacteria in the feces of kids with and without FKS. Nineteen goat kids with clinical signs of FKS, acidemia (pH ≤ 7.2), and plasma D-lactate concentration >7 mM and 15 healthy goat kids without acidemia (pH >7.2) and D-lactate concentration <1 mM. In this case-control study, the goat kids were examined clinically and blood was collected to measure D-lactate concentration, blood gases, and acid-base parameters. Fecal samples were collected and the total aerobic bacterial count and CFU counts of coliforms, enterococci, staphylococci, streptococci, lactobacilli, and clostridia were determined using the surface plating method. Goat kids with FKS had a mean plasma D-lactate concentration of 10.9 ± 3.7 mM compared with 0.3 ± 0.9 mM in healthy kids, and significantly greater CFU counts for enterococci, streptococci, staphylococci, and lactobacilli than healthy kids. The groups of bacteria present in greater numbers in the feces of goat kids with FKS include several D-lactate-producing species, which makes dysbacteriosis a likely cause of the increased plasma D-lactate concentration in FKS. Copyright © 2013 by the American College of Veterinary Internal Medicine.
MCP performance improvement using alumina thin film
NASA Astrophysics Data System (ADS)
Yang, Yuzhen; Yan, Baojun; Liu, Shulin; Zhao, Tianchi; Yu, Yang; Wen, Kaile; Li, Yumei; Qi, Ming
2017-10-01
The performance improvement using alumina thin film on a dual microchannel plate (MCP) detector for single electron counting was investigated. The alumina thin film was coated on all surfaces of the MCPs by atomic layer deposition method. It was found that the gain, the single electron resolution and the peak-to-valley ratio of the dual MCP detector were significantly enhanced by coating the alumina thin film. The optimum operating conditions of the new dual MCP detector have been studied.
Comparative determination of two probiotics by QCM and OWLS-based immunosensors.
Szalontai, Helga; Adányi, Nóra; Kiss, Attila
2014-09-25
The regular consumption of foods containing probiotic bacteria has beneficial physiological effects on the health and the digestion system. There is a need for novel analytical approaches for the determination of these bacteria that are faster than the classical plate counting method. For this purpose, two label-free biosensors were investigated and presented in this paper: Quartz Crystal Microbalance (QCM) and Optical Waveguide Lightmode Spectroscopy (OWLS) based direct immunosensors were developed for real-time direct detection of probiotic bacteria in fermented dairy products. Bifidobacterium bifidum O1356 and Lactobacillus acidophilus O1132 were detected by polyclonal anti-B. bifidum IgG and anti-L. acidophilus IgG immobilized on the sensors' surface. Sulfo-LC-SPDP cross linking agent was used to bind antibodies to the gold surface of the QCM's AT-cut quartz wafer. Concerning OWLS, antibodies were covalently bound to the amino groups of the silanized surface of the waveguide by glutaraldehyde. The dynamic measuring range was found between 1.0E+3 and 5.0E+5CFUmL(-1) in 100 fold diluted fermented milk products by QCM and with OWLS. Considering the current legislation of the probiotic content in probiotic products, the two developed immunosensors can be applied for rapid quantification of L. acidophilus and B. bifidum in fermented milk. These examinations offer effective alternatives to the microbiological plate counting method. Copyright © 2014 Elsevier B.V. All rights reserved.
Standing, Taryn-Ann; du Plessis, Erika; Duvenage, Stacey; Korsten, Lise
2013-06-01
The internalisation potential of Listeria monocytogenes, Staphylococcus aureus, Escherichia coli O157:H7 and Salmonella enterica subsp. enterica serovar Typhimurium in lettuce was evaluated using seedlings grown in vermiculite in seedling trays as well as hydroponically grown lettuce. Sterile distilled water was spiked with one of the four human pathogenic bacteria (10(5) CFU/mL) and used to irrigate the plants. The potential for pathogen internalisation was investigated over time using light microscopy, transmission electron microscopy and viable plate counts. Additionally, the identities of the pathogens isolated from internal lettuce plant tissues were confirmed using polymerase chain reaction with pathogen-specific oligonucleotides. Internalisation of each of the human pathogens was evident in both lettuce seedlings and hydroponically grown mature lettuce plants. To our knowledge, this is the first report of S. aureus internalisation in lettuce plants. In addition, the levels of background microflora in the lettuce plants were determined by plate counting and the isolates identified using matrix-assisted laser ionisation-time of flight (MALDI-TOF). Background microflora assessments confirmed the absence of the four pathogens evaluated in this study. A low titre of previously described endophytes and soil inhabitants, i.e., Enterobacter cloacae, Enterococcus faecalis, Lysinibacillus fusiformis, Rhodococcus rhodochrous, Staphylococcus epidermidis and Staphylococcus hominis were identified.
Chappuy, L; Charroin, C; Vételé, F; Durand, T; Quessada, T; Klotz, M-C; Bréant, V; Aulagner, G
2014-01-01
The parenteral nutrition admixtures are manufactured with an automated compounding BAXA(®) Exacta-Mix 2400. A 48-hour assembly has been validated. To optimize time and cost, a weekly assembly was tested. Assembly was made on the first day. Ten identical parenteral nutrition admixtures (different volumes and compositions) were produced each day. A macroscopic examination was done at D0, D7 and D14. Physicochemical controls (electrolytes determinations by atomic absorption spectrophotometry, osmolalities measurements) were performed. Microbiological tests included a filtration membrane sterility test (Steritest(®)) and a plate count agar environmental monitoring. All mixtures were considered stable. The 12 Steritest(®) (H24, H48, D7 and D14) did not show any bacterial or fungal contamination. No microorganism has been detected on the plate count agar at D4 and D7. Concerning the physicochemical parameters of each parental nutrition admixture, no significant difference (Wilcoxon test) with the first day was found. The automated filling system BAXA(®) Exacta-Mix 2400 improves the quality and safety of production. According to these results, the weekly assembly is validated and permit to save time (80hours/year) and cost (40 000 euros on consumable/year). Copyright © 2013 Elsevier Masson SAS. All rights reserved.
Kim, Hye-Jin; Kim, Dongwook; Kim, Hee-Jin; Song, Sung-Ok; Song, Young-Han; Jang, Aera
2018-01-01
This study was conducted to analyze the microbiological contamination status of raw beef distributed in Korea, and evaluate the suitability of current aerobic plate count (APC) guidelines. We analyzed five years (2010-2014) of microbiological monitoring data obtained from the Ministry of Food and Drug Safety and investigated the microbiological status of raw beef collected from meat packing centers and meat shops in the Seoul/Gyeonggi, Gangwon, and Chungcheong regions in August 2015. From 2010-2014, most raw beef (>94%) displayed APC levels of < 1.0 × 106 CFU/g. However, raw beef samples collected from all three regions in August 2015 had comparatively higher APC levels than those reported in previous years. To evaluate the relationship between the APC level and quality, changes in beef loin were evaluated during cold storage for 15 days at 4°C. On day 11, the mean APC level (4.7 × 106 CFU/g) conformed to current guidelines in Korea (1.0 × 107 CFU/g) and the pH value was 5.82. However, the sensory evaluation score for color and overall acceptability was under 3.0, meaning that the beef loin was not acceptable for eating. These results suggest that current APC guideline for raw beef should be lowered to 1.0 × 106 CFU/g to improve both the microbiological safety and palatability of raw beef. PMID:29725223
Lee, Cheng-Hung; Shih, Cheng-Min; Huang, Kui-Chou; Chen, Kun-Hui; Hung, Li-Kun; Su, Kuo-Chih
2016-11-01
Clinical implantation of clavicle hook plates is often used as a treatment for acromioclavicular joint dislocation. However, it is not uncommon to find patients that have developed acromion osteolysis or had peri-implant fracture after hook plate fixation. With the aim of preventing complications or fixation failure caused by implantation of inappropriate clavicle hook plates, the present study investigated the biomechanics of clavicle hook plates made of different materials and with different hook depths in treating acromioclavicular joint dislocation, using finite element analysis (FEA). This study established four parts using computer models: the clavicle, acromion, clavicle hook plate, and screws, and these established models were used for FEA. Moreover, implantations of clavicle hook plates made of different materials (stainless steel and titanium alloy) and with different depths (12, 15, and 18 mm) in patients with acromioclavicular joint dislocation were simulated in the biomechanical analysis. The results indicate that deeper implantation of the clavicle hook plate reduces stress on the clavicle, and also reduces the force applied to the acromion by the clavicle hook plate. Even though a clavicle hook plate made of titanium alloy (a material with a lower Young's modulus) reduces the force applied to the acromion by the clavicle hook plate, slightly higher stress on the clavicle may occur. The results obtained in this study provide a better reference for orthopedic surgeons in choosing different clavicle hook plates for surgery. Copyright © 2016 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.
Dolan, Anthony; Burgess, Catherine M; Barry, Thomas B; Fanning, Seamus; Duffy, Geraldine
2009-04-01
A sensitive quantitative reverse-transcription PCR (qRT-PCR) method was developed for enumeration of total bacteria. Using two sets of primers separately to target the ribonuclease-P (RNase P) RNA transcripts of gram positive and gram negative bacteria. Standard curves were generated using SYBR Green I kits for the LightCycler 2.0 instrument (Roche Diagnostics) to allow quantification of mixed microflora in liquid media. RNA standards were used and extracted from known cell equivalents and subsequently converted to cDNA for the construction of standard curves. The number of mixed bacteria in culture was determined by qRT-PCR, and the results correlated (r(2)=0.88, rsd=0.466) with the total viable count over the range from approx. Log(10) 3 to approx. Log(10) 7 CFU ml(-1). The rapid nature of this assay (8 h) and its potential as an alternative method to the standard plate count method to predict total viable counts and shelf life are discussed.
Shahsavari, Esmaeil; Aburto-Medina, Arturo; Taha, Mohamed; Ball, Andrew S
2016-01-01
Polycyclic aromatic hydrocarbons (PAHs) are major pollutants globally and due to their carcinogenic and mutagenic properties their clean-up is paramount. Bioremediation or using PAH degrading microorganisms (mainly bacteria) to degrade the pollutants represents cheap, effective methods. These PAH degraders harbor functional genes which help microorganisms use PAHs as source of food and energy. Most probable number (MPN) and plate counting methods are widely used for counting PAHs degraders; however, as culture based methods only count a small fraction (<1%) of microorganisms capable of carrying out PAH degradation, the use of culture-independent methodologies is desirable.•This protocol presents a robust, rapid and sensitive qPCR method for the quantification of the functional genes involved in the degradation of PAHs in soil samples.•This protocol enables us to screen a vast number of PAH contaminated soil samples in few hours.•This protocol provides valuable information about the natural attenuation potential of contaminated soil and can be used to monitor the bioremediation process.