Sample records for platform total knee

  1. Limited rotation of the mobile-bearing in a rotating platform total knee prosthesis.

    PubMed

    Garling, E H; Kaptein, B L; Nelissen, R G H H; Valstar, E R

    2007-01-01

    The hypothesis of this study was that the polyethylene bearing in a rotating platform total knee prosthesis shows axial rotation during a step-up motion, thereby facilitating the theoretical advantages of mobile-bearing knee prostheses. We examined 10 patients with rheumatoid arthritis who had a rotating platform total knee arthroplasty (NexGen LPS mobile, Zimmer Inc. Warsaw, USA). Fluoroscopic data was collected during a step-up motion six months postoperatively. A 3D-2D model fitting technique was used to reconstruct the in vivo 3D kinematics. The femoral component showed more axial rotation than the polyethylene mobile-bearing insert compared to the tibia during extension. In eight knees, the femoral component rotated internally with respect to the tibia during extension. In the other two knees the femoral component rotated externally with respect to the tibia. In all 10 patients, the femur showed more axial rotation than the mobile-bearing insert indicating the femoral component was sliding on the polyethylene of the rotating platform during the step-up motion. Possible explanations are a too limited conformity between femoral component and insert, the anterior located pivot location of the investigated rotating platform design, polyethylene on metal impingement and fibrous tissue formation between the mobile-bearing insert and the tibial plateau.

  2. Comparison of fixed-bearing and mobile-bearing total knee arthroplasty after high tibial osteotomy.

    PubMed

    Hernigou, Philippe; Huys, Maxime; Pariat, Jacques; Roubineau, François; Flouzat Lachaniette, Charles Henri; Dubory, Arnaud

    2018-02-01

    There is no information comparing the results of fixed-bearing total knee replacement and mobile-bearing total knee replacement in the same patients previously treated by high tibial osteotomy. The purpose was therefore to compare fixed-bearing and mobile-bearing total knee replacements in patients treated with previous high tibial osteotomy. We compared the results of 57 patients with osteoarthritis who had received a fixed-bearing prosthesis after high tibial osteotomy with the results of 41 matched patients who had received a rotating platform after high tibial osteotomy. The match was made for length of follow-up period. The mean follow-up was 17 years (range, 15-20 years). The patients were assessed clinically and radiographically. The pre-operative knee scores had no statistically significant differences between the two groups. So was the case with the intra-operative releases, blood loss, thromboembolic complications and infection rates in either group. There was significant improvement in both groups of knees, and no significant difference was observed between the groups (i.e., fixed-bearing and mobile-bearing knees) for the mean Knee Society knee clinical score (95 and 92 points, respectively), or the Knee Society knee functional score (82 and 83 points, respectively) at the latest follow-up. However, the mean post-operative knee motion was higher for the fixed-bearing group (117° versus 110°). In the fixed-bearing group, one knee was revised because of periprosthetic fracture. In the rotating platform mobile-bearing group, one knee was revised because of aseptic loosening of the tibial component. The Kaplan-Meier survivorship for revision at ten years of follow-up was 95.2% for the fixed bearing prosthesis and 91.1% for the rotating platform mobile-bearing prosthesis. Although we did manage to detect significant differences mainly in clinical and radiographic results between the two groups, we found no superiority or inferiority of the mobile-bearing total knee prosthesis over the fixed-bearing total knee prosthesis for patients previously operated by high tibial osteotomy.

  3. Comparison of the clinical outcomes after total knee arthroplasty with the LCS rotating platform mobile bearing knee system and the PFC Sigma RP-F mobile bearing knee system.

    PubMed

    Kwak, Ju-Yeong; Jeong, Jae-Heon; Lee, Sang-Hak; Jung, Ho-Joong; Jung, Young-Bok

    2012-12-01

    We compared clinical outcomes after total knee arthroplasty with the Low Contact Stress (LCS) rotating platform mobile bearing knee system and the Press Fit Condylar Sigma rotating platform high flexion (PFC Sigma RP-F) mobile bearing knee system. Fifty cases of total knee arthroplasty were performed with the PFC Sigma RP-F mobile bearing knee system and sixty-one cases were performed with the LCS mobile bearing total knee arthroplasty. The average duration of follow-up was 2.9 years. The mean Hospital for Special Surgery (HSS) knee score was 62.1 (range, 52 to 75) in the LCS group and 61.9 (range, 50 to 74) in the Sigma RP-F group preoperatively, and 90.1 (range, 84 to 100) in the LCS group and 89.8 (range, 83 to 100) in the Sigma RP-F group at the final follow-up. The mean preoperative flexion contracture was 6.7° (range, 0° to 10°) in the LCS group and 9.3° (range, 0° to 15°) in the Sigma RP-F group preoperatively. The mean range of motion was 124.6° (range, 105° to 150°) in the LCS group and 126.1° (range, 104° to 145°) in the Sigma RP-F group at the final follow-up. After a minimum duration of follow-up of two years, we found no significant differences between the two groups with regard to the range of knee motion or the clinical or radiographic results.

  4. 10-year evaluation of the cementless low-contact- stress rotating-platform total knee arthroplasty.

    PubMed

    Efstathopoulos, Nikolaos; Mavrogenis, Andreas F; Lallos, Stergios; Nikolaou, Vassilios; Papagelopoulos, Panayiotis J; Savvidou, Olga D; Korres, Demetrios S

    2009-01-01

    We present the clinical and radiographic outcomes of the cementless low-contact-stress (LCS) rotating-platform total knee arthroplasty. Overall, 423 prostheses were implanted in 393 consecutive patients (30 patients had bilateral total knee replacement) for primary varus gonarthrosis (381 patients) and rheumatoid arthritis (12 patients). There were 81 men and 312 women with a mean age of 73 years (range, 58-85 years). Patella replacement was not performed in any case. Clinical and radiographic evaluation was performed using the Knee Society Score (KSS) and the Knee Society Assessment Form, respectively. The mean follow-up was 10 years (range, 5-15 years). Three patients were lost to follow-up. Survival of the prostheses was 98% at 10 years; three prostheses required revision for deep infection, bearing dislocation, and periprosthetic fracture. The mean KSS improved significantly, from 42 and 44 points preoperatively to 90 and 79 points, respectively, at the latest evaluation (P < 0.001); results were excellent in 278 cases, good in 106, fair in 27, and poor in nine. Radiolucent lines were observed in 80 cases; revision arthroplasty was not performed in any of these cases. Complications included deep infection in one patient, bearing dislocation in one, skin necrosis in four, and a supracondylar fracture in one. The cementless LCS rotating-platform total knee arthroplasty is associated with excellent mid- and long-term results for patients with osteoarthritis and rheumatoid arthritis of the knee.

  5. No difference between fixed- and mobile-bearing total knee arthroplasty in activities of daily living and pain: a randomized clinical trial.

    PubMed

    Amaro, Joicemar Tarouco; Arliani, Gustavo Gonçalves; Astur, Diego Costa; Debieux, Pedro; Kaleka, Camila Cohen; Cohen, Moises

    2017-06-01

    Until now, there are no definitive conclusions regarding functional differences related to middle- and long-term everyday activities and patient pain following implantation of mobile- and fixed-platform tibial prostheses. The aim of this study was to determine whether there are middle-term differences in knee function and pain in patients undergoing fixed- and mobile-bearing total knee arthroplasty (TKA). Eligible patients were randomized into two groups: the first group received TKA implantation with a fixed tibial platform (group A); the second group received TKA with a mobile tibial platform (group B). Patients were followed up (2 years), and their symptoms and limitations in daily living activities were evaluated using the Knee Outcome Survey-Activities of Daily Living Scale (ADLS), in addition to pain evaluation assessed using the pain visual analogue scale (VAS). There were no significant differences in function and symptoms in the ADLS and VAS between the study groups. The type of platform used in TKA (fixed vs. mobile) does not change the symptoms, function or pain of patients 2 years post-surgery. Although mobile TKAs may have better short-term results, at medium- and long-term follow-up they do not present important clinical differences compared with fixed-platform TKAs. This information is important so that surgeons can choose the most suitable implant for each patient. Randomized clinical trial, Level I.

  6. Vibration platform training in women at risk for symptomatic knee osteoarthritis.

    PubMed

    Segal, Neil A; Glass, Natalie A; Shakoor, Najia; Wallace, Robert

    2013-03-01

    To determine whether a platform exercise program with vibration is more effective than platform exercise alone for improving lower limb muscle strength and power in women ages 45 to 60 with risk factors for knee osteoarthritis (OA). Randomized, controlled study. Academic center. A total of 48 women ages 45-60 years with risk factors for knee OA (a history of knee injury or surgery or body mass index ≥25 kg/m(2)). Subjects were randomly assigned to a twice-weekly lower limb exercise program (quarter squat, posterolateral leg lifts, calf raises, step-ups, and lunges) on either a vertically vibrating platform (35 Hz, 2 mm) or a nonvibrating platform. Change in isokinetic quadriceps strength, leg press power, and stair climb power by 12 weeks. A total of 39 of 48 enrolled participants completed the study (26 vibration and 13 control exercise). Nine participants discontinued the study after randomization mainly because of a lack of time. No intergroup differences in age, body mass index, or activity level existed. Isokinetic knee extensor strength did not significantly improve in either group. Leg press power improved by 92.0 ± 69.7 W in the vibration group (P < .0001) and 58.2 ± 96.2 W in the control group (P = .0499) but did not differ between groups (P = .2262). Stair climb power improved by 53.4 ± 64.7 W in the vibration group (P = .0004) and 55.7 ± 83.3 W in the control group (P = .0329) but did not differ between groups (P = .9272). Whole body vibration platforms have been marketed for increasing strength and power. In this group of asymptomatic middle-aged women with risk factors for knee OA, the addition of vibration to a 12-week exercise program did not result in significantly greater improvement in lower limb strength or power than did participation in the exercise program without vibration. Copyright © 2013 American Academy of Physical Medicine and Rehabilitation. Published by Elsevier Inc. All rights reserved.

  7. Unsatisfactory clinical outcomes of second-generation mobile bearing floating platform total knee arthroplasty: comparing outcomes with fixed bearing after five years minimum.

    PubMed

    Yoon, Jung-Ro; Yang, Jae-Hyuk

    2018-03-20

    The purpose of this retrospective study was to analyze and compare the clinical and radiologic outcomes of fixed bearing ultracongruent (UC) insert total knee arthroplasty (TKA) and mobile bearing (MB) floating platform TKA using the navigation-assisted gap balancing technique with a minimum follow-up of five years. The study retrospectively enrolled 105 patients who received the UC type fixed bearing insert (group 1) and 95 patients who received the floating platform MB insert (group 2) during the period from August 2009 to June 2012. All surgery was performed using the navigation-assisted gap balancing technique. For strict assessment of gap measurements, the offset-type-force-controlled-spreader-system was used. Radiologic and clinical outcomes were assessed before operation and at the most recent follow-up using the Knee Society Score (KSS) and the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) score. For statistical analysis, paired sample t tests were used. A p value less than 0.05 was considered significant. Although the radiologic alignments were satisfactory for both groups (99/105 [94%] cases were neutral for group 1 and 90/95 [94%] for group 2), the functional and total WOMAC scores were inferior in group 2 (p < 0.05). There were two cases of insert breakage in group 2 that required bearing exchange. The Kaplan-Meier survivorship rates for groups 1 and 2 at 77 months were 100.0 and 97.9%, respectively. Second-generation MB floating platform TKA cases did not have satisfactory outcomes. There were two cases of insert breakage, which required bearing exchange. Other patients who underwent surgery with second-generation MB floating platform were encouraged to avoid high knee flexion activities, resulting in lower clinical performance.

  8. Late dislocation of rotating platform in New Jersey Low-Contact Stress knee prosthesis.

    PubMed

    Huang, Chun-Hsiung; Ma, Hon-Ming; Liau, Jiann-Jong; Ho, Fang-Yuan; Cheng, Cheng-Kung

    2002-12-01

    Five patients with late rotational dislocation of the rotating platform bearing in the New Jersey Low-Contact Stress total knee arthroplasty are reported. The prostheses had functioned well for 8 to 12 years before failure. Preoperative radiographs showed asymmetric femorotibial joint spaces. Entrapment of the dislocated bearing in three patients and spontaneous reduction of the dislocated bearing in another two patients were seen at revision. Femorotibial ligamentous instability was found after reduction. The retrieved polyethylene bearings showed advanced wear and cold flow deformities and the thickness was reduced. The revision arthroplasty was accomplished by replacement with a thicker bearing element. Progressive femorotibial ligament laxity and reduction of the thickness of polyethylene with wearing break down the originally well-balanced soft tissue tension of the knee. The rotational degree of the rotating platform bearing is unrestricted, which may result in late dislocation. Polyethylene wear is unavoidable in knee prostheses using metal contact with polyethylene even with a mobile-bearing design. Efforts to reduce polyethylene wear are mandatory.

  9. Intraoperative evaluation of total knee replacement: kinematic assessment with a navigation system.

    PubMed

    Casino, Daniela; Zaffagnini, Stefano; Martelli, Sandra; Lopomo, Nicola; Bignozzi, Simone; Iacono, Francesco; Russo, Alessandro; Marcacci, Maurilio

    2009-04-01

    Interest in the kinematics of reconstructed knees has increased since it was shown that the alteration of knee motion could lead to abnormal wear and damage to soft tissues. We performed intraoperative kinematic measurements using a navigation system to study knee kinematics before and after posterior substituting rotating platform total knee arthroplasty (TKA). We verified intraoperatively (1) if varus/valgus (VV) laxity and anterior/posterior (AP) laxity were restored after TKA; (2) if TKA induced abnormal femoral rollback; and (3) how tibial axial rotation was influenced by TKA throughout the range of flexion. We found that TKA improved alignment in preoperative osteoarthritic varus knees which became neutral after surgery and maintained a neutral alignment in neutral knees. The VV stability at 0 degrees was restored while AP laxity at 90 degrees significantly increased after TKA. Following TKA, the femur had an abnormal anterior translation up to 60 degrees of flexion, followed by a small rollback of 12 +/- 5 mm. TKA influenced the tibia rotation pattern during flexion, but not the total amount of internal/external rotation throughout whole range of flexion, which was preserved after TKA (6 degrees +/- 5 degrees ). This study showed that the protocol proposed might be useful to adjust knee stability at time zero and that knee kinematic outcome during total knee replacement can be monitored by a navigation system.

  10. Knee stability before and after total and unicondylar knee replacement: in vivo kinematic evaluation utilizing navigation.

    PubMed

    Casino, Daniela; Martelli, Sandra; Zaffagnini, Stefano; Lopomo, Nicola; Iacono, Francesco; Bignozzi, Simone; Visani, Andrea; Marcacci, Maurilio

    2009-02-01

    Surgical navigation systems are currently used to guide the surgeon in the correct alignment of the implant. The aim of this study was to expand the use of navigation systems by proposing a surgical protocol for intraoperative kinematics evaluations during knee arthroplasty. The protocol was evaluated on 20 patients, half undergoing unicondylar knee arthroplasty (UKA) and half undergoing posterior-substituting, rotating-platform total knee arthroplasty (TKA). The protocol includes a simple acquisition procedure and an original elaboration methodology. Kinematic tests were performed before and after surgery and included varus/valgus stress at 0 and 30 degrees and passive range of motion. Both UKA and TKA improved varus/valgus stability in extension and preserved the total magnitude of screw-home motion during flexion. Moreover, compared to preoperative conditions, values assumed by tibial axial rotation during flexion in TKA knees were more similar to the rotating patterns of UKA knees. The analysis of the anteroposterior displacement of the knee compartments confirmed that the two prostheses did not produce medial pivoting, but achieved a postoperative normal behavior. These results demonstrated that proposed intraoperative kinematics evaluations by a navigation system provided new information on the functional outcome of the reconstruction useful to restore knee kinematics during surgery.

  11. The Role of Virtual Rehabilitation in Total Knee and Hip Arthroplasty.

    PubMed

    Chughtai, Morad; Newman, Jared M; Sultan, Assem A; Khlopas, Anton; Navarro, Sergio M; Bhave, Anil; Mont, Michael A

    2018-06-01

    Virtual rehabilitation therapies have been developed to focus on improving care for those suffering from various musculoskeletal disorders. There has been evidence suggesting that real-time virtual rehabilitation may be equivalent to conventional methods for adherence, improvement of function, and relief of pain seen in these conditions. This study specifically evaluated the use of a virtual physical therapy/rehabilitation platform for use during the postoperative period after total hip arthroplasty (THA) and total knee arthroplasty (TKA). The use of this technology has the potential benefits that allow for patient adherence, cost reductions, and coordination of care.

  12. Difference in knee rotation between total and unicompartmental knee arthroplasties during stair climbing.

    PubMed

    Jung, Myung-Chul; Chung, Jun Young; Son, Kwang-Hyun; Wang, Hui; Hwang, Jaejin; Kim, Jay Joong; Kim, Joon Ho; Min, Byoung-Hyun

    2014-08-01

    The purpose of this study was to compare knee kinematics during stair walking in patients with simultaneous total knee arthroplasty (TKA) and unicompartmental knee arthroplasties (UKA). It was hypothesized that UKA would reproduce more normalized knee kinematics than TKA during stair ascent and descent. Six patients who received UKA in one knee and TKA in the other knee were included in the study. For this study, a four-step staircase was assembled with two force platforms being positioned at the centre of the second and third steps. Each patient was attached with 16 reflective markers at both lower extremities and was asked to perform five roundtrip trials of stair climbing. Kinematic parameters including stance duration, knee angle, vertical ground reaction force (GRF), joint reaction force, and moments were obtained and analysed using a10-camera motion system (VICON, Oxford, UK). Nonparametric Friedman test was used to compare the results between two arthroplasty methods and between stair ascent and descent. Compared to TKA, UKA knees exhibited significantly greater degree of rotation in transverse planes (5.0 degrees during ascent and 6.0 degrees during descent on average), but showed no difference in terms of the other parameters. When comparing the results during stair ascent with descent, overall greater knee angle, vertical GRF, joint reaction force, and moment were observed during stair descent. Both UKA and TKA knees have shown overall similar knee kinematics, though UKA knee may allow greater degree of rotation freedom, which resembles normal knee kinematics during stair walking.

  13. A comparative analysis between fixed bearing total knee arthroplasty (PFC Sigma) and rotating platform total knee arthroplasty (PFC-RP) with minimum 3-year follow-up.

    PubMed

    Jawed, Akram; Kumar, Vijay; Malhotra, R; Yadav, C S; Bhan, S

    2012-06-01

    Since the introduction of mobile bearing total knee designs nearly 30 years back, many studies have been done to evaluate its long-term result. Comparison with fixed bearing designs has been done in the past, but the studies were confounded by variables such as disease, surgeon, bone quality, pain tolerance, etc. We attempt to eliminate these variables in this study. A total of 50 patients who had bilateral arthritis of the knee with similar deformity and pre-operative range of motion on both sides agreed to have one knee replaced with mobile bearing total knee design (PFC-RP) and the other with a fixed bearing design (PFC Sigma) were prospectively evaluated. Comparative analysis of both the designs was done at a mean follow-up of 40 months, minimizing patient, surgeon and observer related bias. Clinical and radiographic outcome, survival and complication rates were compared. At a mean follow-up of 40 months (range 36-47 months), no benefit of mobile bearing (PFC-RP) over fixed bearing design (PFC Sigma) could be demonstrated with respect to Knee Society scores, pain scores, range of flexion, subject preference or patello-femoral complication rates. Radiographs showed no difference in prosthetic alignment. No patient required a revision surgery till last follow-up. Our study demonstrated no advantage of the mobile-bearing arthroplasty over fixed bearing arthroplasty with regard to clinical results at short-term follow-up. However, longer follow-up is necessary to confirm whether these results are sustained.

  14. Increased risk of aseptic loosening for 43,525 rotating-platform vs. fixed-bearing total knee replacements

    PubMed Central

    Gothesen, Oystein; Lygre, Stein Hakon L; Lorimer, Michelle; Graves, Stephen; Furnes, Ove

    2017-01-01

    Background and purpose — Given similar functional outcomes with mobile and fixed bearings, a difference in survivorship may favor either. This study investigated the risk of aseptic loosening for the most used subtypes of mobile-bearing rotating-platform knees, in Norway and Australia. Patients and methods — Primary TKRs reported to the Norwegian and Australian joint registries, between 2003 and 2014, were analyzed with aseptic loosening as primary end-point and all revisions as secondary end-point. We hypothesized that no difference would be found in the rate of revision between rotating-platform and the most used fixed-bearing TKRs, or between keeled and non-keeled tibia. Kaplan–Meier estimates and curves, and Cox regression relative risk estimates adjusted for age, sex, and diagnosis were used for comparison. Results — The rotating-platform TKRs had an increased risk of revision for aseptic loosening compared with the most used fixed-bearing knees, in Norway (RR =6, 95% CI 4–8) and Australia (RR =2.1, 95% CI 1.8–2.5). The risk of aseptic loosening as a reason for revision was highest in Norway compared with Australia (RR =1.7, 95% CI 1.4–2.0). The keeled tibial component had the same risk of aseptic loosening as the non-keeled tibia (Australia). Fixation method and subtypes of the tibial components had no impact on the risk of aseptic loosening in these mobile-bearing knees. Interpretation — The rotating-platform TKRs in this study appeared to have a higher risk of revision for aseptic loosening than the most used fixed-bearing TKRs. PMID:28929828

  15. Improvement in the clinical practicability of roentgen stereophotogrammetric analysis (RSA): free from the use of the dual X-ray equipment.

    PubMed

    Shih, Kao-Shang; Lee, Chian-Her; Syu, Ci-Bin; Lai, Jiing-Yih; Chen, Kuo-Jen; Lin, Shang-Chih

    2012-10-01

    After total knee replacement, the monitoring of the prosthetic performance is often done by roentgenographic examination. However, the two-dimensional (2D) roentgen images only provide information about the projection onto the anteroposterior (AP) and mediolateral (ML) planes. Historically, the model-based roentgen stereophotogrammetric analysis (RSA) technique has been developed to predict the spatial relationship between prostheses by iteratively comparing the projective data for the prosthetic models and the roentgen images. During examination, the prosthetic poses should be stationary. This should be ensured, either by the use of dual synchronized X-ray equipment or by the use of a specific posture. In practice, these methods are uncommon or technically inconvenient during follow-up examination. This study aims to develop a rotation platform to improve the clinical applicability of the model-based RSA technique. The rotation platform allows the patient to assume a weight-bearing posture, while being steadily rotated so that both AP and ML knee images can be obtained. This study uses X-ray equipment with a single source and flat panel detectors (FPDs). Four tests are conducted to evaluate the quality of the FPD images, steadiness of the rotation platform, and accuracy of the RSA results. The results show that the distortion-induced error of the FPD image is quite minor, and the prosthetic size can be cautiously calibrated by means of the scale ball(s). The rotation platform should be placed closer to the FPD and orthogonal to the projection axis of the X-ray source. Image overlap of the prostheses can be avoided by adjusting both X-ray source and knee posture. The device-induced problems associated with the rotation platform include the steadiness of the platform operation and the balance of the rotated subject. Sawbone tests demonstrate that the outline error, due to the platform, is of the order of the image resolution (= 0.145 mm). In conclusion, the rotation platform with steady rotation, a knee support, and a handle can serve as an alternative method to take prosthetic images, without the loss in accuracy associated with the RSA method.

  16. [Investigation of body weight ratios on joint structures at different knee flexion angles in patients with unilateral knee arthroplasty].

    PubMed

    Bakırhan, Serkan; Unver, Bayram; Karatosun, Vasfi

    2013-01-01

    The study aims to determine body weight ratios between extremities in patients with unilateral total knee arthroplasty (TKA) at 12 months postoperatively at the static-standing position at 30, 60 and 90 degrees of knee flexion. The study included 52 female patients (mean age 65.6±10.6 years; range 40 to 83 years) who underwent unilateral primary TKA. The force-platform was used to calculate the body-weight ratios of the patients. Body weight ratios on the operated and non-operated limbs of the unilateral TKA patients were examined at standing-static position at 30, 60 and 90 degrees of knee flexion on the force-platform according to their age and body mass index (BMI). The pain levels of the patients were evaluated using the visual analog scale. It was found that unilateral TKA patients placed their body weight on the non-operated limb more at the standing-static position, and 30, 60 and 90 degrees of knee flexion at 12 months postoperatively (p<0.05). It was also found that as the knee flexion degree increased with age, so did TKA patients place their body weight on the nonoperated limb more (p<0.05), and that BMI had no effect on the load distribution difference over the two extremities (p>0.05). During the postoperative period, load asymmetry between the two extremities in patients with unilateral TKA remains the same due to advancing age. This accelerates the osteoarthritis process on the non-operated knee. It is concluded that the age factor should be taken into account while planning physiotherapy and rehabilitation programs for unilateral TKA patients and knee exercise programs aiming to place load over the operated limb should be arranged.

  17. Comparison of the low contact stress and press fit condylar rotating-platform mobile-bearing prostheses in total knee arthroplasty: a prospective randomized study.

    PubMed

    Kim, Young-Hoo; Kim, Jun-Shik; Park, Jang-Won; Joo, Jong-Hwan

    2011-06-01

    To our knowledge, no study to date has compared the clinical results of posterior cruciate-sacrificing mobile-bearing total knee replacements with those of posterior-stabilized mobile-bearing total knee replacements in the same patients. The purpose of the present study was to compare the clinical and radiographic results of these two designs. We hypothesized that the results would be better for knees treated with the posterior-stabilized mobile-bearing prosthesis. The present study consisted of a consecutive series of 107 female patients (mean age, 66.8 years) who underwent bilateral simultaneous total knee arthroplasty at the same surgical setting. All of these patients received a posterior cruciate-sacrificing mobile-bearing prosthesis in one knee and a posterior-stabilized mobile-bearing prosthesis in the contralateral knee. At the time of each follow-up (mean, 7.4 years; range, seven to 7.6 years), the patients were assessed clinically. The mean postoperative Knee Society knee score (96 compared with 97 points) and Hospital for Special Surgery knee score (93 compared with 94 points) were similar between the two groups. At the time of the latest follow-up, the average range of motion was 127.7° (range, 70° to 150°) in the knees with a posterior cruciate-sacrificing mobile-bearing prosthesis and 132.4° (range, 90° to 150°) in the knees with a posterior-stabilized mobile-bearing prosthesis. With a margin of error of the manual measurement of 5°, this difference was not significant. The estimated survival rate was 97.2% (95% confidence interval, 91% to 99%) at seven years in the posterior-cruciate sacrificing mobile-bearing prosthesis group and 98.1% (95% confidence interval, 92% to 99%) at seven years in the posterior-stabilized mobile-bearing prosthesis group. After a minimum duration of follow-up of seven years, we found no significant differences between the two groups with regard to the clinical and radiographic results, including knee range of motion.

  18. Differential bacterial load on components of total knee prosthesis in patients with prosthetic joint infection.

    PubMed

    Holinka, Johannes; Pilz, Magdalena; Hirschl, Alexander M; Graninger, Wolfgang; Windhager, Reinhard; Presterl, Elisabeth

    2012-10-01

    The purpose of our study was to evaluate and quantify the bacterial adherence on different components of total knee prosthesis with the sonication culture method. Explanted components of all patients with presumptive prosthetic or implant infection were treated by sonication separately in sterile containers to dislodge the adherent bacteria from the surfaces and cultured. The bacterial load of the different knee components (femur, tibia, PE-inlay and patella) was evaluated by counting of colony-forming units (CFU) dislodged from the components surfaces using the sonication culture method. Overall, 27 patients had positive sonication cultures of explanted total knee prostheses. Microorganisms were detected from 88 of 100 explanted components. Twenty femoral components were culture positive and 7 negative, 23 tibial components as well as 23 polyethylene (PE) platforms had positive microorganism detection from the surface. Staphylococcus epidermidis adhered to the highest number of components whereas Staphylococcus aureus yielded the highest load of CFU in the sonication cultures. Although not significant, PE-inlays and tibial components were most often affected. The highest CFU count was detected in polyethylene components. The sonication culture method is a reliable method to detect bacteria from the components. Additionally, the results demonstrate that bacterial adherence is not affecting a single component of knee prosthesis only. Thus, in septic revision surgery partial prosthetic exchange or exchange of single polyethylene components alone may be not sufficient.

  19. What have we learned from 100% success of press fit condylar rotating platform posterior stabilized knees?: A 5-10 years followup by a nondesigner.

    PubMed

    Vaidya, Shrinand V; Virani, Siddharth; Phunde, Rajendra; Mahajan, Abhishek

    2016-01-01

    Total joint arthroplasties of the hip and knee represent a remarkable feat of modern medicine in terms of reducing pain and restoring function to millions of patients afflicted with severe arthritis. Oftentimes, the performance and longevity of new implants and devices are based on limited data. This is the first study by a non-designer on the press fit condylar rotating platform posterior stabilized (PFC-RP-PS) design with 100' success. This has a relevance, vis-á -vis bias that one may have in terms of reproducibility of technique and funding from the manufacturer. We associate our excellent mid-term results to intra operative technical aspects and stringent intra operative exclusion criteria. Our study includes a cohort of 121 selected knees operated between January 2003 and October 2010. We used cemented, posterior stabilized (PS), mobile bearing (MB), and RP prosthesis from the same manufacturer in all these 121 knees. The patients were evaluated bi-annually with the calculation of their Knee Society Scores (KSS) and a radiological assessment for loosening/osteolysis. 120 knees were available for followup. The average Knee Society clinical and functional scores, respectively, were 27 points and 40 points preoperatively and 93 points and 95 points postoperatively. This indicates a mean increase of about 71' in the clinical score and about 58' in the functional score, which is statistically significant. The mean postoperative flexion was 124°, a mean increase of 23° from the preoperative flexion of 101°. There were no revisions (Kaplan--Meier survivorship of 100'). We feel durable and reproducible results of PFC-RP-PS design knees are very technique sensitive. The way ahead with the PFC-RP-PS knees looks promising when the exclusion criteria for this design are strictly met. Coming from a non-designer, this study acquires a higher degree of relevance without any designer's or manufacturer's bias.

  20. Supporting the Delivery of Total Knee Replacements Care for Both Patients and Their Clinicians With a Mobile App and Web-Based Tool: Randomized Controlled Trial Protocol.

    PubMed

    Hussain, M Sazzad; Li, Jane; Brindal, Emily; van Kasteren, Yasmin; Varnfield, Marlien; Reeson, Andrew; Berkovsky, Shlomo; Freyne, Jill

    2017-03-01

    Total knee replacement (TKR) surgeries have increased in recent years. Exercise programs and other interventions following surgery can facilitate the recovery process. With limited clinician contact time, patients with TKR have a substantial burden of self-management and limited communication with their care team, thus often fail to implement an effective rehabilitation plan. We have developed a digital orthopedic rehabilitation platform that comprises a mobile phone app, wearable activity tracker, and clinical Web portal in order to engage patients with self-management tasks for surgical preparation and recovery, thus addressing the challenges of adherence to and completion of TKR rehabilitation. The study will determine the efficacy of the TKR platform in delivering information and assistance to patients in their preparation and recovery from TKR surgery and a Web portal for clinician care teams (ie, surgeons and physiotherapists) to remotely support and monitor patient progress. The study will evaluate the TKR platform through a randomized controlled trial conducted at multiple sites (N=5) in a number of states in Australia with 320 patients undergoing TKR surgery; the trial will run for 13 months for each patient. Participants will be randomized to either a control group or an intervention group, both receiving usual care as provided by their hospital. The intervention group will receive the app and wearable activity tracker. Participants will be assessed at 4 different time points: 4 weeks before surgery, immediately before surgery, 12 weeks after surgery, and 52 weeks after surgery. The primary outcome measure is the Oxford Knee Score. Secondary outcome measures include quality of life (Short-Form Health Survey); depression, anxiety, and stress (Depression, Anxiety, and Stress Scales); self-motivation; self-determination; self-efficacy; and the level of satisfaction with the knee surgery and care delivery. The study will also collect quantitative usage data related to all components (app, activity tracker, and Web portal) of the TKR platform and qualitative data on the perceptions of the platform as a tool for patients, carers, and clinicians. Finally, an economic evaluation of the impact of the platform will be conducted. Development of the TKR platform has been completed and deployed for trial. The research protocol is approved by 2 human research ethics committees in Australia. A total of 5 hospitals in Australia (2 in New South Wales, 2 in Queensland, and 1 in South Australia) are expected to participate in the trial. The TKR platform is designed to provide flexibility in care delivery and increased engagement with rehabilitation services. This trial will investigate the clinical and behavioral efficacy of the app and impact of the TKR platform in terms of service satisfaction, acceptance, and economic benefits of the provision of digital services. Australian New Zealand Clinical Trials Registry (ANZCTR) ACTRN12616000504415; https://www.anzctr.org.au/Trial/Registration/TrialReview.aspx?id=370536 (Archived by WebCite at http://www.webcitation.org/6oKES0Gp1). ©M Sazzad Hussain, Jane Li, Emily Brindal, Yasmin van Kasteren, Marlien Varnfield, Andrew Reeson, Shlomo Berkovsky, Jill Freyne. Originally published in JMIR Research Protocols (http://www.researchprotocols.org), 01.03.2017.

  1. Posterior Shift of Contact Point between Femoral Component and Polyethylene in the LCS Rotating Platform Implant under Weight Bearing Condition.

    PubMed

    Oh, Won Seok; Lee, Yong Seuk; Kim, Byung Kak; Sim, Jae Ang; Lee, Beom Koo

    2016-06-01

    To analyze the contact mechanics of the femoral component and polyethylene of the Low Contact Stress rotating platform (LCS-RP) in nonweight bearing and weight bearing conditions using full flexion lateral radiographs. From May 2009 to December 2013, 58 knees in 41 patients diagnosed with osteoarthritis and treated with total knee arthroplasty (TKA) were included in this study. TKA was performed using an LCS-RP knee prosthesis. Full flexion lateral radiographs in both weight bearing and nonweight bearing condition were taken at least one month postoperatively (average, 28.8 months). Translation of femoral component was determined by the contact point between the femoral component and polyethylene. Maximum flexion was measured as the angle between the lines drawn at the midpoint of the femur and tibia. Posterior shift of the contact point in LCS-RP TKA was observed under weight bearing condition, which resulted in deeper flexion compared to LCS-RP TKA under nonweight bearing condition. In the LCS-RP TKA, the contact point between the femoral component and polyethylene moved posteriorly under weight bearing condition, and the joint was more congruent and maximum flexion increased with weight bearing.

  2. Risk factors for manipulation after total knee arthroplasty: a pooled electronic health record database study.

    PubMed

    Pfefferle, Kiel J; Shemory, Scott T; Dilisio, Matthew F; Fening, Stephen D; Gradisar, Ian M

    2014-10-01

    A commercially available software platform, Explorys (Explorys, Inc., Cleveland, OH), was used to mine a pooled electronic healthcare database consisting of the medical records of more than 27 million patients. A total of 229,420 patients had undergone a total knee arthroplasty; 3470 (1.51%) patients were identified to have undergone manipulation under anesthesia. Individual risk factors of being female, African American race, age less than 60, BMI >30 and nicotine dependence were determined to have relative risk of 1.25, 2.20, 3.46, 1.33 and 1.32 respectively. Depressive disorder, diabetes mellitus, opioid abuse/dependence and rheumatoid arthritis were not significant risk factors. African Americans under the age of 60 at time of TKA had the greatest incidence of MUA (5.17%) and relative risk of 3.73 (CI: 3.36, 4.13). Copyright © 2014 Elsevier Inc. All rights reserved.

  3. Determining the True Cost to Deliver Total Hip and Knee Arthroplasty Over the Full Cycle of Care: Preparing for Bundling and Reference-Based Pricing.

    PubMed

    DiGioia, Anthony M; Greenhouse, Pamela K; Giarrusso, Michelle L; Kress, Justina M

    2016-01-01

    The Affordable Care Act accelerates health care providers' need to prepare for new care delivery platforms and payment models such as bundling and reference-based pricing (RBP). Thriving in this environment will be difficult without knowing the true cost of care delivery at the level of the clinical condition over the full cycle of care. We describe a project in which we identified true costs for both total hip and total knee arthroplasty. With the same tool, we identified cost drivers in each segment of care delivery and collected patient experience information. Combining cost and experience information with outcomes data we already collect allows us to drive costs down while protecting outcomes and experiences, and compete successfully in bundling and RBP programs. Copyright © 2016 Elsevier Inc. All rights reserved.

  4. Changes in the three-dimensional load-bearing axis after mobile-bearing total knee arthroplasty.

    PubMed

    Ishii, Yoshinori; Noguchi, Hideo; Sato, Junko; Ezawa, Nobukazu; Toyabe, Shin-Ichi

    2016-07-01

    The purpose of this study was to assess changes in the three-dimensional (3D) load-bearing mechanical axis (LBMA) preoperatively and at 3 weeks and more than 1-year follow-up after total knee arthroplasty (TKA), and effects of the degree of constraint in the anteroposterior (AP) direction because of the retention of the posterior cruciate ligament (PCL) and the implant design on the changes in LBMA. We evaluated 157 knees from 131 patients, including 79 knees that received meniscal-bearing-type (PCL-retaining) and 78 knees that received rotating-platform-type (PCL-substituting) prostheses. Quantitative 3D computed tomography was used to assess changes in the location of the pre- and postoperative LBMA at the tibial plateau level. Changes in the 3D axis were mainly found from medial to lateral and posterior to anterior in both implant designs with no significant differences. Change in the mediolateral (ML) direction was improved soon after TKA, but change in the AP direction improved more gradually over time. The different constraints in the AP direction because of the retention of the PCL and different implant designs did not affect the changes in the LBMA. The LBMA in the AP direction more than 1 year postoperatively, as well as the LBMA in the ML direction at 3 weeks, appears to shift toward the location found in normal knees after TKA, regardless of the type of prosthetic constraint. These changes may be an important factor that influences the periarticular knee bone mineral density which load bearing may be related to. Level II, Prognostic study.

  5. OpenSim as a preliminary kinematic testing platform for the development of total knee arthroplasty implants.

    PubMed

    Chan, Hao Yang; Walker, Peter S

    2018-05-18

    The design of a total knee replacement implant needs to take account the complex surfaces of the knee which it is replacing. Ensuring design performance of the implant requires in vitro testing of the implant. A considerable amount of time is required to produce components and evaluate them inside an experimental setting. Numerous adjustments in the design of an implant and testing each individual design can be time consuming and expensive. Our solution is to use the OpenSim simulation software to rapidly test multiple design configurations of implants. This study modeled a testing rig which characterized the motion and laxity of knee implants. Three different knee implant designs were used to test and validate the accuracy of the simulation: symmetrical, asymmetric, and anatomic. Kinematics were described as distances measured from the center of each femoral condyle to a plane intersecting the most posterior points of the tibial condyles between 0 and 135° of flexion with 15° increments. Excluding the initial flexion measurement (∼0°) results, the absolute differences between all experimental and simulation results (neutral path, anterior-posterior shear, internal-external torque) for the symmetric, asymmetric, and anatomical designs were 1.98 mm ± 1.15, 1.17 mm ± 0.89, and 1.24 mm ± 0.97, respectively. Considering all designs, the accuracy of the simulation across all tests was 1.46 mm ± 1.07. It was concluded that the results of the simulation were an acceptable representation of the testing rig and hence applicable as a design tool for new total knees. Copyright © 2018 Elsevier Ltd. All rights reserved.

  6. Different intraoperative kinematics with comparable clinical outcomes of ultracongruent and posterior stabilized mobile-bearing total knee arthroplasty.

    PubMed

    Kim, Tae Woo; Lee, Sang Min; Seong, Sang Cheol; Lee, Sahnghoon; Jang, Jak; Lee, Myung Chul

    2016-09-01

    There remains no consensus as to whether mobile total knee arthroplasty (TKA) should use a posterior cruciate ligament-sacrificing ultracongruent (UC) or a posterior cruciate ligament-substituting posterior stabilized (PS) prosthesis. The purpose of this study was to assess intraoperative kinematics and clinical outcomes of UC and PS rotating platform mobile-bearing TKA. In this randomized controlled study, mobile UC TKA prostheses (n = 45) were compared with mobile PS TKA prostheses (n = 45) with regard to intraoperative kinematics and clinical outcomes. The passive kinematic study using intraoperative navigation system included anterior/posterior translation, varus/valgus alignment and rotation of femur during flexion. The patients were clinically and radiographically evaluated over a 3-year follow-up. Paradoxical anterior translation of the femur was 10.8 ± 5.2 mm in the UC knee from 0° to 82° of knee flexion and 8.7 ± 3.0 mm in the PS knee from 0° to 70° of knee flexion (p = 0.027). Paradoxical internal rotation of the femur was 5.8° in the UC knees and 9.9° in the PS knees (p = 0.003). But, there was no significant difference between the groups in regard to the coronal alignment. There was no significant difference in the range of motion, KS knee scores, KS function scores, and WOMAC index scores. Despite different intraoperative kinematics between mobile UC and mobile PS TKA, neither design reproduced physiologic knee kinematics and there was no difference in clinical outcomes between the two groups. The clinical relevance of the study is that despite different intraoperative kinematics, UC design can be a considerable alternative to PS design in mobile-bearing TKA in respect of clinical outcomes. II.

  7. Evidence for differential control of tibial position in perturbed unilateral stance after acute ACL rupture.

    PubMed

    Chmielewski, T L; Ramsey, D K; Snyder-Mackler, L

    2005-01-01

    Functional outcomes in anterior cruciate ligament-deficient "potential copers" and "non-copers" may be related to their knee stabilization strategies. Therefore, the purpose of this study was to differentiate dynamic knee stabilization strategies of potential copers and non-copers through analysis of sagittal plane knee angle and tibia position during disturbed and undisturbed unilateral standing. Ten uninjured potential coper and non-coper subjects stood in unilateral stance on a platform that translated anteriorly, posteriorly and laterally. Knee angle and tibia position with reference to the femur were calculated before and after platform movement. During perturbation trials, potential copers maintained kinematics that were similar to uninjured subjects across conditions. Conversely, non-copers stood with greater knee flexion than uninjured subjects and a tibia position that was more posterior than the other groups. Both non-copers and potential copers demonstrated small changes in tibia position following platform movement, but direction of movement was not similar. The similarities between the knee kinematics of potential copers and uninjured subjects suggest that potential copers compensated well from their injury by utilizing analogous dynamic knee stabilization strategies. In comparison to the other groups, by keeping the knee in greater flexion and the tibia in a more posterior position, non-copers appear to constrain the tibia in response to a challenging task, which is consistent with a "stiffening strategy". Based on the poor functional outcomes of non-copers, a stiffening strategy does not lead to dynamic knee stability, and the strategy may increase compressive forces which could contribute to or exacerbate articular cartilage degeneration.

  8. Migration and clinical outcome of mobile-bearing versus fixed-bearing single-radius total knee arthroplasty.

    PubMed

    Van Hamersveld, Koen T; Marang-Van De Mheen, Perla J; Van Der Heide, Huub J L; Van Der Linden-Van Der Zwaag, Henrica M J; Valstar, Edward R; Nelissen, Rob G H H

    2018-04-01

    Background and purpose - Mobile-bearing total knee prostheses (TKPs) were developed in the 1970s in an attempt to increase function and improve implant longevity. However, modern fixed-bearing designs like the single-radius TKP may provide similar advantages. We compared tibial component migration measured with radiostereometric analysis (RSA) and clinical outcome of otherwise similarly designed cemented fixed-bearing and mobile-bearing single-radius TKPs. Patients and methods - RSA measurements and clinical scores were assessed in 46 randomized patients at baseline, 6 months, 1 year, and annually thereafter up to 6 years postoperatively. A linear mixed-effects model was used to analyze the repeated measurements. Results - Both groups showed comparable migration (p = 0.3), with a mean migration at 6-year follow-up of 0.90 mm (95% CI 0.49-1.41) for the fixed-bearing group compared with 1.22 mm (95% CI 0.75-1.80) for the mobile-bearing group. Clinical outcomes were similar between groups. 1 fixed-bearing knee was revised for aseptic loosening after 6 years and 2 knees (1 in each group) were revised for late infection. 2 knees (1 in each group) were suspected for loosening due to excessive migration. Another mobile-bearing knee was revised after an insert dislocation due to failure of the locking mechanism 6 weeks postoperatively, after which study inclusion was preliminary terminated. Interpretation - Fixed-bearing and mobile-bearing single-radius TKPs showed similar migration. The latter may, however, expose patients to more complex surgical techniques and risks such as insert dislocations inherent to this rotating-platform design.

  9. Mobile-bearing knees reduce rotational asymmetric wear.

    PubMed

    Ho, Fang-Yuan; Ma, Hon-Ming; Liau, Jiann-Jong; Yeh, Chuan-Ren; Huang, Chun-Hsiung

    2007-09-01

    Polyethylene wear of bearing components is the most common long-term complication in total knee arthroplasty. One would anticipate differing kinematics would generate different wear patterns (including wear type, degree, and symmetry) on the articulating surface of mobile-bearing and fixed-bearing inserts. Because mobile-bearing designs facilitate movement of the insert relative to the tray when the knee rotates, we hypothesized mobile-bearing designs would reduce the incidence of rotational asymmetric wear. We examined 51 worn tibial inserts, including 15 from mobile-bearing rotating-platform posterior-cruciate-sacrificing dished prostheses and 36 from fixed-bearing posterior-cruciate-retaining flat prostheses, which were retrieved at revision surgery with an average implantation time of 115 months. We divided wear types into low-grade wear (burnishing, abrasion, and cold flow) and high-grade wear (scratching, pitting, metal embedding, and delamination) to assess wear degree of polyethylene. To assess symmetry of wear, the insert surface was divided into medial and lateral sides and each side was further divided into three equal zones along the anteroposterior direction. Low-grade wear was more common in mobile-bearing knees, whereas high-grade wear was more common in fixed-bearing knees. We identified no internal/external rotational asymmetric wear or anteroposterior asymmetric wear in mobile-bearing knees.

  10. Strategies utilized to transfer weight during knee flexion and extension with rotation for individuals with a total knee replacement.

    PubMed

    Ferris, Lauren A; Denney, Linda M; Maletsky, Lorin P

    2013-02-01

    Functional activities in daily life can require squatting and shifting body weight during transverse plane rotations. Stability of the knee can be challenging for people with a total knee replacement (TKR) due to reduced proprioception, nonconforming articular geometry, muscle strength, and soft tissue weakness. The objective of this study was to identify strategies utilized by individuals with TKR in double-stance transferring load during rotation and flexion. Twenty-three subjects were recruited for this study: 11 TKR subjects (age: 65 ± 6 years; BMI 27.4 ± 4.1) and 12 healthy subjects (age: 63 ± 7; BMI 24.6 ± 3.8). Each subject completed a novel crossover button push task where rotation, flexion, and extension of the knee were utilized. Each subject performed two crossover reaching tasks where the subject used the opposite hand to cross over their body and press a button next to either their shoulder (high) or knee (low), then switched hands and rotated to press the opposite button, either low or high. The two tasks related to the order they pressed the buttons while crossing over, either low-to-high (L2H) or high-to-low (H2L). Force platforms measured ground reaction forces under each foot, which were then converted to lead force ratios (LFRs) based on the total force. Knee flexion angles were also measured. No statistical differences were found in the LFRs during the H2L and L2H tasks for the different groups, although differences in the variation of the loading within subjects were noted. A significant difference was found between healthy and unaffected knee angles and a strong trend between healthy and affected subject's knee angles in both H2L and L2H tasks. Large variations in the LFR at mid-task in the TKR subjects suggested possible difficulties in maintaining positional stability during these tasks. The TKR subjects maintained more of an extended knee, which is a consistent quadriceps avoidance strategy seen by other researchers in different tasks. These outcomes suggest that individuals with a TKR utilize strategies, such as keeping an extended knee, to achieve rotary tasks during knee flexion and extension. Repeated compensatory movements could result in forces that may cause difficulty over time in the hip joints or low back. Early identification of these strategies could improve TKR success and the return to activities of daily living that involve flexion and rotation.

  11. Sex differences in lower extremity biomechanics during single leg landings.

    PubMed

    Schmitz, Randy J; Kulas, Anthony S; Perrin, David H; Riemann, Bryan L; Shultz, Sandra J

    2007-07-01

    Females have an increased incident rate of anterior cruciate ligament tears compared to males. Biomechanical strategies to decelerate the body in the vertical direction have been implicated as a contributing cause. This study determined if females would exhibit single leg landing strategies characterized by decreased amounts of hip, knee, and ankle flexion resulting in greater vertical ground reaction forces and altered energy absorption patterns when compared to males. Recreationally active males (N=14) and females (N=14), completed five single leg landings from a 0.3m height onto a force platform while three-dimensional kinematics and kinetics were simultaneously collected. Compared to males, females exhibited (1) less total hip and knee flexion displacements (40% and 64% of males, respectively, P<0.05) and less time to peak hip and knee flexion (48% and 78% of males, respectively, P<0.05), (2) 9% greater peak vertical ground reaction forces (P<0.05), (3) less total lower body energy absorption (76% of males, P<0.05), and (4) 11% greater relative energy absorption at the ankle (P<0.05). Females in this study appear to adopt a single leg landing style using less hip and knee flexion, absorbing less total lower body energy with more relative energy at the ankle resulting in a landing style that can be described as stiff. This may potentially cause increased demands on non-contractile components of the lower extremity. Preventative training programs designed to prevent knee injury may benefit from the biomechanical description of sex-specific landing methods demonstrated by females in this study by focusing on the promotion of more reliance on using the contractile components to absorb impact energy during landings.

  12. Sports activity following total knee arthroplasty in patients older than 60 years.

    PubMed

    Mayr, Hermann O; Reinhold, Maik; Bernstein, Anke; Suedkamp, Norbert P; Stoehr, Amelie

    2015-01-01

    In a retrospective study with a population over 65 years, sports activity was conducted 6 years after cruciate retaining (CR) total condylar knee arthroplasty (TKA) with rotating platform (RP). Eighty-one Patients (71.8±5.4years) were examined at follow-up 6.4±0.9 years postoperative. Sport was practiced 5.3 hours every week in mean. Patients were active in sports 3.5times per week. Twenty-five percent performed high impact sports, 47% medium impact sports and 52% low impact sports at follow-up. In KOOS sports 60±28 was reached, in WOMAC 12.1±15.1. It can be concluded that in this population 50% of patients were active in medium and low impact sport 6 years after surgery. However, a quarter of patients were also active in high impact sports. Copyright © 2014 Elsevier Inc. All rights reserved.

  13. Vibration Platform Training in Women at Risk for Symptomatic Knee Osteoarthritis

    PubMed Central

    Segal, Neil A.; Glass, Natalie A.; Shakoor, Najia; Wallace, Robert

    2013-01-01

    Objective To determine whether a platform exercise program with vibration is more effective than the platform exercise alone for improving lower limb muscle strength and power in women age 45-60 with risk factors for knee osteoarthritis (OA). Design Randomized, controlled study Setting Academic center Participants 48 women age 45-60 years old with risk factors for knee OA (history of knee injury or surgery or BMI≥25kg/m2). Interventions Subjects were randomized to a twice weekly lower limb exercise program (quarter squat, posterolateral leg lifts, calf raises) on either a vertically vibrating (35Hz, 2mm), or a non-vibrating platform. Main Outcome Measurements The main outcome measures included change in isokinetic quadriceps strength, leg press power, and stair climb power by 12 weeks. Results 39 out of 48 enrolled participants completed the study (26 vibration and 13 control exercise). Nine participants discontinued the study after randomization mainly due to lack of time. There were no intergroup differences in age, BMI, or activity level. Isokinetic knee extensor strength did not significantly improve in either group. Leg press power improved by 92.0±69.7 W in the vibration group (p<.0001) and 58.2±96.2 W in the control group (p=0.0499), but did not differ between groups (p=0.2262). Stair climb power improved by 53.4±64.7 W in the vibration group (p=0.0004) and 55.7±83.3 W in the control group (p=0.0329), but did not differ between groups (p=0.9272). Conclusions Whole body vibration platforms have been marketed for increasing strength and power. In this group of asymptomatic middle-aged women with risk factors for knee OA, addition of vibration to a 12-week exercise program did not result in significantly greater improvement in lower limb strength or power than participation in the exercise program without vibration. PMID:22981005

  14. Migration and clinical outcome of mobile-bearing versus fixed-bearing single-radius total knee arthroplasty

    PubMed Central

    Van Hamersveld, Koen T; Marang-Van De Mheen, Perla J; Van Der Heide, Huub J L; Van Der Linden-Van Der Zwaag, Henrica M J; Valstar, Edward R; Nelissen, Rob G H H

    2018-01-01

    Background and purpose Mobile-bearing total knee prostheses (TKPs) were developed in the 1970s in an attempt to increase function and improve implant longevity. However, modern fixed-bearing designs like the single-radius TKP may provide similar advantages. We compared tibial component migration measured with radiostereometric analysis (RSA) and clinical outcome of otherwise similarly designed cemented fixed-bearing and mobile-bearing single-radius TKPs. Patients and methods RSA measurements and clinical scores were assessed in 46 randomized patients at baseline, 6 months, 1 year, and annually thereafter up to 6 years postoperatively. A linear mixed-effects model was used to analyze the repeated measurements. Results Both groups showed comparable migration (p = 0.3), with a mean migration at 6-year follow-up of 0.90 mm (95% CI 0.49–1.41) for the fixed-bearing group compared with 1.22 mm (95% CI 0.75–1.80) for the mobile-bearing group. Clinical outcomes were similar between groups. 1 fixed-bearing knee was revised for aseptic loosening after 6 years and 2 knees (1 in each group) were revised for late infection. 2 knees (1 in each group) were suspected for loosening due to excessive migration. Another mobile-bearing knee was revised after an insert dislocation due to failure of the locking mechanism 6 weeks postoperatively, after which study inclusion was preliminary terminated. Interpretation Fixed-bearing and mobile-bearing single-radius TKPs showed similar migration. The latter may, however, expose patients to more complex surgical techniques and risks such as insert dislocations inherent to this rotating-platform design. PMID:29448880

  15. The Role of Virtual Rehabilitation in Total and Unicompartmental Knee Arthroplasty.

    PubMed

    Chughtai, Morad; Kelly, John J; Newman, Jared M; Sultan, Assem A; Khlopas, Anton; Sodhi, Nipun; Bhave, Anil; Kolczun, Michael C; Mont, Michael A

    2018-03-16

    This study evaluated the use of telerehabilitation during the postoperative period for patients who underwent total knee arthroplasty (TKA) or unicompartmental knee arthroplasty (UKA). Specifically, this study evaluated the following: (1) patient compliance and adherence to the program, (2) time spent performing physical therapy exercises, (3) the usability of the virtual rehabilitation platform, and (4) clinical outcome scores in a selected primary knee arthroplasty cohort. A total of 157 consecutive patients underwent TKA ( n  = 18) or UKA ( n  = 139). These patients used a telerehabilitation system with an instructional avatar, three-dimensional motion measurement and analysis software, and real-time televisit capability designed for arthroplasty patients. Compliance was determined by how many times the patients followed prescribed repetitions of exercises. The total time spent performing exercises for each patient was collected. The usability of the virtual rehabilitation platform (on the patient's end) was evaluated using the system usability scale (SUS) questionnaire. The number of in-person and televisits was recorded for each patient. Patient-reported outcomes were collected through the patient and clinician interfaces and included the Knee Society Score (KSS) for pain and functions, the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) score, and Boston University Activity Measure for Post-Acute Care (AM-PAC) score. Patients spent an average of 29.5 days partaking in the therapy. TKA and UKA patients had a mean of 3.5 and 3.2 outpatient follow-up visits, each, for in-office therapy with a physical therapist, respectively. This figure exceeded the mean number of real-time virtual patient-clinician visits by 0.8 visits per patient in the TKA cohort and by 1 visit per patient in the UKA cohort. Patients spent on average 26.5 minutes per day conducting an average of 13.5 exercises. By the end of rehabilitation, patients had spent an average of 10.8 hours performing exercises, and of all the exercises performed, approximately 21 exercises were uniquely designed. Mean SUS score in the cohort was 93 points, which was interpreted as being above the 50th percentile point of the scale. Following therapy, KSS pain and function scores improved markedly and the improvements were measured at 368% for TKA and 350% for UKA (pain) and 27% for UKA and 33% for TKA (function). In addition, WOMAC scores improved by 57% and 66% for UKA and TKA patients while the improvement in AM-PAC scores was at 22% and 24%. This telerehabilitation platform encouraged clinician-patient interaction beyond the hospital setting and offers the advantage of cost savings, convenience, at-home monitoring, and coordination of care, all of which are geared to improve adherence and overall patient satisfaction. Additionally, the biometric data can be used to develop custom physical therapy regimens to assure proper rehabilitation, which is lacking in other telerehabilitation applications that use noninteractive videos that can be watched on mobile devices and tablets. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  16. P.F.C Sigma® cruciate retaining fixed-bearing versus mobile-bearing knee arthroplasty: a prospective comparative study with minimum 10-year follow-up.

    PubMed

    Riaz, O; Aqil, A; Sisodia, G; Chakrabarty, G

    2017-12-01

    To prospectively compare long-term clinical and radiological outcomes following a cruciate retaining fixed-bearing (FB) and a mobile-bearing (MB) primary total knee replacement (TKR). We prospectively reviewed 113 TKRs in 99 patients (14 bilateral) with a PFC sigma cruciate retaining rotating platform system, at an average follow-up of 11.1 years (range 10-12). Results were contrasted with those from 89 TKRs in 72 patients (17 bilateral) with a PFC sigma cruciate fixed-bearing prosthesis, at an average follow-up of 12.1 years (range 10-14.1). Outcomes collected included pre- and post-operative range of motion, Oxford Knee Scores, complications encountered, as well as radiographical assessments of polyethylene wear. In the MB group, mean Oxford Knee Scores improved from 16 pre-operatively to 42 at final follow-up. The mean range of motion was 115° (75-130). In the FB group, mean Oxford Knee Scores improved from 16.2 pre-operatively to 42.5 at final follow-up. The mean range of motion was 111.2 (80-135) degrees at final follow-up. We failed to elicit an objectively demonstrable clinical difference between the MB- and FB-implanted knees. Similarly, radiological benefits of the MB implants with regard to polyethylene wear were not evident at a minimum 10-year follow-up.

  17. Behavioral effect of knee joint motion on body's center of mass during human quiet standing.

    PubMed

    Yamamoto, Akio; Sasagawa, Shun; Oba, Naoko; Nakazawa, Kimitaka

    2015-01-01

    The balance control mechanism during upright standing has often been investigated using single- or double-link inverted pendulum models, involving the ankle joint only or both the ankle and hip joints, respectively. Several studies, however, have reported that knee joint motion during quiet standing cannot be ignored. This study aimed to investigate the degree to which knee joint motion contributes to the center of mass (COM) kinematics during quiet standing. Eight healthy adults were asked to stand quietly for 30s on a force platform. Angular displacements and accelerations of the ankle, knee, and hip joints were calculated from kinematic data obtained by a motion capture system. We found that the amplitude of the angular acceleration was smallest in the ankle joint and largest in the hip joint (ankle < knee < hip). These angular accelerations were then substituted into three biomechanical models with or without the knee joint to estimate COM acceleration in the anterior-posterior direction. Although the "without-knee" models greatly overestimated the COM acceleration, the COM acceleration estimated by the "with-knee" model was similar to the actual acceleration obtained from force platform measurement. These results indicate substantial effects of knee joint motion on the COM kinematics during quiet standing. We suggest that investigations based on the multi-joint model, including the knee joint, are required to reveal the physiologically plausible balance control mechanism implemented by the central nervous system. Copyright © 2014 Elsevier B.V. All rights reserved.

  18. Level of response to telematic questionnaires on Health Related Quality of Life on total knee replacement.

    PubMed

    Besalduch-Balaguer, M; Aguilera-Roig, X; Urrútia-Cuchí, G; Puntonet-Bruch, A; Jordan-Sales, M; González-Osuna, A; Celaya-Ibáñez, F; Colomina-Morales, J

    2015-01-01

    Questionnaires measuring health-related quality of life are difficult to perform and obtain for patients and professionals. Computerised tools are now available to collect this information. The objective of this study was to assess the ability of patients undergoing total knee replacement to fill in health-related quality-of-life questionnaires using a telematic platform. Ninety eight consecutive patients undergoing total knee arthroplasty were included. Participants were given an access code to enter the website where they had to respond to 2 questionnaires (SF8 and the reduced WOMAC), and 3 additional questions about the difficulty in completing the questionnaires. A total of 98 patients agreed to participate: 45 males and 53 females (mean age 72.7 years). Fourteen did not agree to participate due to lack of internet access. Of the final 84 participants, 50% entered the website, and only 36 answered all questions correctly. Of the patients who answered the questionnaire, 80% were helped by a relative or friend, and 22% reported difficulty accessing internet. The use of telematic systems to respond to health-related quality of life questionnaires should be used cautiously, especially in elderly population. It is likely that the population they are directed at is not prepared to use this type of technology. Therefore, before designing telematics questionnaires it must be ensured that they are completed properly. Copyright © 2014 SECOT. Published by Elsevier Espana. All rights reserved.

  19. KNEE-JOINT LOADING IN KNEE OSTEOARTHRITIS: INFLUENCE OF ABDOMINAL AND THIGH FAT

    PubMed Central

    Messier, Stephen P.; Beavers, Daniel P.; Loeser, Richard F.; Carr, J. Jeffery; Khajanchi, Shubham; Legault, Claudine; Nicklas, Barbara J.; Hunter, David J.; DeVita, Paul

    2014-01-01

    Purpose Using three separate models that included total body mass, total lean and total fat mass, and abdominal and thigh fat as independent measures, we determined their association with knee-joint loads in older overweight and obese adults with knee osteoarthritis (OA). Methods Fat depots were quantified using computed tomography and total lean and fat mass determined with dual energy x-ray absorptiometry in 176 adults (age = 66.3 yr., BMI = 33.5 kg·m−2) with radiographic knee OA. Knee moments and joint bone-on-bone forces were calculated using gait analysis and musculoskeletal modeling. Results Higher total body mass was significantly associated (p ≤ 0.0001) with greater knee compressive and shear forces, compressive and shear impulses (p < 0.0001), patellofemoral forces (p< 0.006), and knee extensor moments (p = 0.003). Regression analysis with total lean and total fat mass as independent variables revealed significant positive associations of total fat mass with knee compressive (p = 0.0001), shear (p < 0.001), and patellofemoral forces (p = 0.01) and knee extension moment (p = 0.008). Gastrocnemius and quadriceps forces were positively associated with total fat mass. Total lean mass was associated with knee compressive force (p = 0.002). A regression model that included total thigh and total abdominal fat found both were significantly associated with knee compressive and shear forces (p ≤ 0.04). Thigh fat was associated with the knee abduction (p = 0.03) and knee extension moment (p = 0.02). Conclusions Thigh fat, consisting predominately of subcutaneous fat, had similar significant associations with knee joint forces as abdominal fat despite its much smaller volume and could be an important therapeutic target for people with knee OA. PMID:25133996

  20. Knee joint loading in knee osteoarthritis: influence of abdominal and thigh fat.

    PubMed

    Messier, Stephen P; Beavers, Daniel P; Loeser, Richard F; Carr, J Jeffery; Khajanchi, Shubham; Legault, Claudine; Nicklas, Barbara J; Hunter, David J; Devita, Paul

    2014-09-01

    Using three separate models that included total body mass, total lean and total fat mass, and abdominal and thigh fat as independent measures, we determined their association with knee joint loads in older overweight and obese adults with knee osteoarthritis (OA). Fat depots were quantified using computed tomography, and total lean and fat mass were determined with dual energy x-ray absorptiometry in 176 adults (age, 66.3 yr; body mass index, 33.5 kg·m) with radiographic knee OA. Knee moments and joint bone-on-bone forces were calculated using gait analysis and musculoskeletal modeling. Higher total body mass was significantly associated (P ≤ 0.0001) with greater knee compressive and shear forces, compressive and shear impulses (P < 0.0001), patellofemoral forces (P < 0.006), and knee extensor moments (P = 0.003). Regression analysis with total lean and total fat mass as independent variables revealed significant positive associations of total fat mass with knee compressive (P = 0.0001), shear (P < 0.001), and patellofemoral forces (P = 0.01) and knee extension moment (P = 0.008). Gastrocnemius and quadriceps forces were positively associated with total fat mass. Total lean mass was associated with knee compressive force (P = 0.002). A regression model that included total thigh and total abdominal fat found that both were significantly associated with knee compressive and shear forces (P ≤ 0.04). Thigh fat was associated with knee abduction (P = 0.03) and knee extension moment (P = 0.02). Thigh fat, consisting predominately of subcutaneous fat, had similar significant associations with knee joint forces as abdominal fat despite its much smaller volume and could be an important therapeutic target for people with knee OA.

  1. Revision of Unicondylar to Total Knee Arthroplasty: A Systematic Review

    PubMed Central

    Siddiqui, Nashat A; Ahmad, Zafar M

    2012-01-01

    Isolated unicompartmental osteoarthritis in the young patient is a difficult problem to treat; they may be too young to consider total knee arthroplasty due to difficulties with inevitable future revision. Unicompartmental knee arthroplasty is one possible solution as it is perceived by some as being a smaller surgical insult than total knee arthroplasty, with easier revision to total knee arthroplasty than a revision total knee arthroplasty. A total knee arthroplasty performed as a revision unicondylar knee arthroplasty is thought by some authors to have equivalent functional outcomes to a primary total knee replacement. However, there have been several studies suggesting that revision is not as simple as suggested, and that function is not as good as primary total knee arthroplasty. We performed a systematic review of the literature regarding outcomes after revision of a unicondylar knee arthroplasty. Although there are many studies proposing selective use of the unicondylar knee arthroplasty, there are a number of studies highlighting difficulties with revision and poorer outcomes, and, therefore, the unicondylar knee arthroplasty cannot be considered a small procedure that will 'buy time' for the patient, and have results equal to a primary knee arthroplasty when revised. Further controlled studies, ideally randomised, are required before final conclusions can be drawn. PMID:22905072

  2. Reducing gender disparities in post-total knee arthroplasty expectations through a decision aid.

    PubMed

    Volkmann, Elizabeth R; FitzGerald, John D

    2015-02-07

    Gender disparities in total knee arthroplasty utilization may be due to differences in perceptions and expectations about total knee arthroplasty outcomes. This study evaluates the impact of a decision aid on perceptions about total knee arthroplasty and decision-making parameters among patients with knee osteoarthritis. Patients with moderate to severe knee osteoarthritis viewed a video about knee osteoarthritis treatments options, including total knee arthroplasty, and received a personalized arthritis report. An adapted version of the Western Ontario and McMaster Universities Osteoarthritis Index was used to assess pain and physical function expectations following total knee arthroplasty before/after the intervention. These scores were compared to an age- and gender-adjusted means for a cohort of patients who had undergone total knee arthroplasty. Decision readiness and conflict were also measured. At baseline, both men and women had poorer expectations about post-operative pain and physical outcomes compared with observed outcomes of the comparator group. Following the intervention, women's mean age-adjusted expectations about post- total knee arthroplasty pain outcomes improved (Pre: 27.0; Post: 21.8 [p =0.08; 95% CI -0.7, 11.0]) and were closer to observed post-TKA outcomes; whereas men did not have a significant change in their pain expectations (Pre: 21.3; Post: 19.6 [p = 0.6; 95% CI -5.8, 9.4]). Women also demonstrated a significant improvement in decision readiness; whereas men did not. Both genders had less decision conflict after the intervention. Both women and men with osteoarthritis had poor estimates of total knee arthroplasty outcomes. Women responded to the intervention with more accurate total knee arthroplasty outcome expectations and greater decision readiness. Improving patient knowledge of total knee arthroplasty through a decision aid may improve medical decision-making and reduce gender disparities in total knee arthroplasty utilization.

  3. Effects of different foot progression angles and platform settings on postural stability and fall risk in healthy and medial knee osteoarthritic adults.

    PubMed

    Khan, Saad Jawaid; Khan, Soobia Saad; Usman, Juliana; Mokhtar, Abdul Halim; Abu Osman, Noor Azuan

    2018-02-01

    This study aims to investigate the effects of varying toe angles at different platform settings on Overall Stability Index of postural stability and fall risk using Biodex Balance System in healthy participants and medial knee osteoarthritis patients. Biodex Balance System was employed to measure postural stability and fall risk at different foot progression angles (ranging from -20° to 40°, with 10° increments) on 20 healthy (control group) and 20 knee osteoarthritis patients (osteoarthritis group) randomly (age: 59.50 ± 7.33 years and 61.50 ± 8.63 years; body mass: 69.95 ± 9.86 kg and 70.45 ± 8.80 kg). Platform settings used were (1) static, (2) postural stability dynamic level 8 (PS8), (3) fall risk levels 12 to 8 (FR12) and (4) fall risk levels 8 to 2 (FR8). Data from the tests were analysed using three-way mixed repeated measures analysis of variance. The participant group, platform settings and toe angles all had a significant main effect on balance ( p ≤ 0.02). Platform settings had a significant interaction effect with participant group F(3, 144) = 6.97, p < 0.01 and toe angles F(21, 798) = 2.83, p < 0.01. Non-significant interactions were found for group × toe angles, F(7, 266) = 0.89, p = 0.50, and for group × toe angles × settings, F(21, 798) = 1.07, p = 0.36. The medial knee osteoarthritis group has a poorer postural stability and increased fall risk as compared to the healthy group. Changing platform settings has a more pronounced effect on balance in knee osteoarthritis group than in healthy participants. Changing toe angles produced similar effects in both the participant groups, with decreased stability and increased fall risk at extreme toe-in and toe-out angles.

  4. Posterior dislocation following revision total knee replacement arthroplasty: a case report and literature analysis.

    PubMed

    Lee, Ho Min; Kim, Jong Pil; Chung, Phil Hyun; Kang, Suk; Kim, Young Sung; Go, Bo Seong

    2018-05-24

    Knee dislocation following total knee replacement arthroplasty is a rare but serious complication. The incidence of dislocation following primary total knee arthroplasty with posterior stabilized implants ranges from 0.15 to 0.5%, and posterior dislocation after revision total knee arthroplasty is even rarer. Here, we report the case of a 76-year-old male who presented with posterior dislocation after posterior stabilized revision total knee arthroplasty.

  5. The Cost-Effectiveness of Surgical Treatment of Medial Unicompartmental Knee Osteoarthritis in Younger Patients

    PubMed Central

    Konopka, Joseph F.; Gomoll, Andreas H.; Thornhill, Thomas S.; Katz, Jeffrey N.; Losina, Elena

    2015-01-01

    Background: Surgical options for the management of medial compartment osteoarthritis of the varus knee include high tibial osteotomy, unicompartmental knee arthroplasty, and total knee arthroplasty. We sought to determine the cost-effectiveness of high tibial osteotomy and unicompartmental knee arthroplasty as alternatives to total knee arthroplasty for patients fifty to sixty years of age. Methods: We built a probabilistic state-transition computer model with health states defined by pain, postoperative complications, and subsequent surgical procedures. We estimated transition probabilities from published literature. Costs were determined from Medicare reimbursement schedules. Health outcomes were measured in quality-adjusted life-years (QALYs). We conducted analyses over patients’ lifetimes from the societal perspective, with health and cost outcomes discounted by 3% annually. We used probabilistic sensitivity analyses to account for uncertainty in data inputs. Results: The estimated discounted QALYs were 14.62, 14.63, and 14.64 for high tibial osteotomy, unicompartmental knee arthroplasty, and total knee arthroplasty, respectively. Discounted total direct medical costs were $20,436 for high tibial osteotomy, $24,637 for unicompartmental knee arthroplasty, and $24,761 for total knee arthroplasty (in 2012 U.S. dollars). The incremental cost-effectiveness ratio (ICER) was $231,900 per QALY for total knee arthroplasty and $420,100 per QALY for unicompartmental knee arthroplasty. Probabilistic sensitivity analyses showed that, at a willingness-to-pay (WTP) threshold of $50,000 per QALY, high tibial osteotomy was cost-effective 57% of the time; total knee arthroplasty, 24%; and unicompartmental knee arthroplasty, 19%. At a WTP threshold of $100,000 per QALY, high tibial osteotomy was cost-effective 43% of time; total knee arthroplasty, 31%; and unicompartmental knee arthroplasty, 26%. Conclusions: In fifty to sixty-year-old patients with medial unicompartmental knee osteoarthritis, high tibial osteotomy is an attractive option compared with unicompartmental knee arthroplasty and total knee arthroplasty. This finding supports greater utilization of high tibial osteotomy for these patients. The cost-effectiveness of high tibial osteotomy and of unicompartmental knee arthroplasty depend on rates of conversion to total knee arthroplasty and the clinical outcomes of the conversions. Level of Evidence: Economic Level II. See Instructions for Authors for a complete description of levels of evidence. PMID:25995491

  6. Effect of voluntary soft tissue tension and articular conformity after total knee arthroplasty on in vivo anteroposterior displacement.

    PubMed

    Ishii, Y; Noguchi, H; Takeda, M; Kiga, H; Toyabe, S I

    2011-01-01

    The in vivo relationship between the degree of voluntary soft tissue tension and articular conformity after total knee arthroplasty (TKA) and anteroposterior (AP) displacement was simultaneously investigated by analyzing LCS prostheses (posterior cruciate ligament-sacrificing rotating platform design) in 20 knees from 20 patients. AP displacement was measured using the KT-2000 arthrometer, at 30° and 75° flexion, while patients were conscious and under anesthesia; 30° flexion was regarded as high conformity and 75° as low conformity. Mean displacements at 30° and 75° were 5.1mm and 7.0mm, respectively, in conscious patients, and 6.7 mm and 7.7 mm, respectively, in patients under anesthesia. AP displacement was significantly associated with soft tissue tension (p=0.026) and conformity (p=0.001). No interaction was observed between the two variables (p=0.193). Surgeons should recognize that AP displacement is greater in anesthetized patients than in conscious patients, regardless of the degree of conformity, and that higher conformity shows less displacement, regardless of the degree of soft tissue tension. These results may help surgeons to determine the intra-operative AP displacement required for proper postoperative displacement in the current prosthetic design. Copyright © 2009 Elsevier B.V. All rights reserved.

  7. The use of synthetic ligaments in the design of an enhanced stability total knee joint replacement.

    PubMed

    Stokes, Michael D; Greene, Brendan C; Pietrykowski, Luke W; Gambon, Taylor M; Bales, Caroline E; DesJardins, John D

    2018-03-01

    Current total knee replacement designs work to address clinically desired knee stability and range of motion through a balance of retained anatomy and added implant geometry. However, simplified implant geometries such as bearing surfaces, posts, and cams are often used to replace complex ligamentous constraints that are sacrificed during most total knee replacement procedures. This article evaluates a novel total knee replacement design that incorporates synthetic ligaments to enhance the stability of the total knee replacement system. It was hypothesized that by incorporating artificial cruciate ligaments into a total knee replacement design at specific locations and lengths, the stability of the total knee replacement could be significantly altered while maintaining active ranges of motion. The ligament attachment mechanisms used in the design were evaluated using a tensile test, and determined to have a safety factor of three with respect to expected ligamentous loading in vivo. Following initial computational modeling of possible ligament orientations, a physical prototype was constructed to verify the function of the design by performing anterior/posterior drawer tests under physiologic load. Synthetic ligament configurations were found to increase total knee replacement stability up to 94% compared to the no-ligament case, while maintaining total knee replacement flexion range of motion between 0° and 120°, indicating that a total knee replacement that incorporates synthetic ligaments with calibrated location and lengths should be able to significantly enhance and control the kinematic performance of a total knee replacement system.

  8. [Knee arthrodesis performed with intramedullary nailing technique in failed total knee replacement--a preliminary report].

    PubMed

    Gaździk, Tadeusz Szymon; Kotas-Strzoda, Justyna; Bozek, Marek

    2004-01-01

    Knee arthrodesis is the method of choice in treatment of failed total knee replacement. It is recommended when revisory total knee replacement is impossible. The authors present 2 cases of knee fusions using intramedullary nails after prosthesis loosening (1 aseptic, 1 septic). In both cases good results were achieved, with no complications observed during convalescence.

  9. Total knee arthroplasty in patients with a previous patellectomy.

    PubMed

    Maslow, Jed; Zuckerman, Joseph D; Immerman, Igor

    2013-01-01

    Post-patellectomy patients represent a specific subgroup of patients that may develop arthritis and persistent knee pain and potentially require treatment with total knee arthroplasty. This article reviews the treatment and functional outcomes following total knee arthroplasty in patients with prior patellectomy. A case report is presented as an example of the clinical management of a post-patellectomy patient with significant knee pain and disability treated with total knee arthroplasty. Emphasis will be placed in decision- making, specifically with the use of a posterior stabilized implant. In addition, postoperative strengthening of the quadriceps is essential to compensate for the lack of the patella and increase the success of total knee arthroplasty in this subgroup of patients.

  10. One Stage Conversion of an Infected Fused Knee to Total Knee Replacement - A Surgical Challenge

    PubMed Central

    Ravikumar, Mukartihal; Kendoff, Daniel; Citak, Mustafa; Luck, Stefan; Gehrke, Thorsten; Zahar, Akos

    2013-01-01

    Background and Purpose: Two-stage revision arthroplasty is a common technique for the treatment of infected total knee replacement. Few reports have addressed the conversion of a fused knee into a total knee replacement. However, there is no case reported of converting an infected fused knee into a hinge knee using a one-stage procedure. Methods: We report on a 51-year old male patient with an infected fused knee after multiple surgeries. Results and Interpretation: A one-stage conversion of septic fused knee into total knee arthroplasty by a rotational hinge prosthesis was performed. The case highlights that with profound preoperative assessment, meticulous surgical technique, combined antibiotic treatment and the right implant, one-stage revision in a surgical challenge may have a role as a treatment option with good functional outcome. PMID:23526706

  11. Total knee arthroplasty in limbs affected by poliomyelitis.

    PubMed

    Giori, Nicholas J; Lewallen, David G

    2002-07-01

    Little information is available regarding the results and complications of total knee arthroplasty in limbs affected by poliomyelitis with severe knee degeneration. We performed a retrospective chart and radiograph review of patients with a history of poliomyelitis involving a limb that subsequently underwent primary total knee arthroplasty between 1970 and 2000. Sixteen total knee arthroplasties were performed in limbs affected by poliomyelitis in fifteen patients. Eleven patients were followed for a minimum of two years, one (two knees) died before the minimum two-year follow-up could be completed, and three were followed for less than two years. No patient was lost to follow-up. There were two periprosthetic fractures, one peroneal nerve palsy, one avulsion of the patellar tendon, and four cases of recurrent instability. These complications were related to the poor bone quality, valgus deformity, patella baja, poor musculature, and attenuated soft tissues commonly found in knees affected by poliomyelitis. Knee Society pain and knee scores were improved postoperatively for all nine knees with a two-year follow-up that had had at least antigravity quadriceps strength prior to surgery. However, Knee Society function scores remained at 0 or worsened for six of the eleven knees followed for at least two years, including those with less than antigravity strength, and four of the nine knees with at least antigravity strength. None of the prostheses loosened. Pain and knee scores improved following total knee arthroplasty in patients with a history of poliomyelitis and antigravity quadriceps strength, but there was less pain relief in patients with less than antigravity quadriceps strength. Recurrence of instability and progressive functional deterioration is possible in all knees affected by poliomyelitis that have undergone total knee replacement, but they appear to occur more commonly in more severely affected knees.

  12. [The impact of dynamic platform exercises on knee joint muscle strength in patients with gonarthrosis treated with microfracture method].

    PubMed

    Klupiński, Kamil; Krochmalski, Jakub; Woldańska-Okońska, Marta

    2017-06-23

    Osteoarthritis is the most common joint disease. Gonarthrosis is one of the most serious diseases the highly developed modern medicine must face. The number of patients suffering from joint pain and progressive disability is growing, especially in economically developed countries. Over the years, the disease has been considered merely as a symptom of aging and the effect of "wear and tear" of the cartilage. At present it is known that the degenerative joint disease is of chronic and progressive nature and its pathogenesis is complex. The aim of the study was to determine the impact of dynamic platform exercises on knee joint muscle strength in patients with gonarthrosis treated with microfracture method. The study included 120 patients of both sexes, aged 40 to 65 years, height range1.60-1.90 m., weight 50- 100 kg. Patients were divided into two groups. Group I of 60 patients after knee arthroscopy (with performed microfractures on the articular cartilage) who were subjected to physiotherapy with the use of dynamometric platform and to isometric and dynamic exercises of muscles surrounding the knee joint. Group II (control) of 60 patients after knee arthroscopy (with performed microfractures on the articular cartilage), who were subjected only to isometric and dynamic exercises of muscles surrounding the knee joint. The patients underwent rehabilitation according to the same rehabilitation program suggested by the Medical Magnus Clinic in Lodz, which consisted in performing daily exercises in open and closed kinetic chains. All Group I and II patients were examined three times: before the start of the rehabilitation, after 4th week of rehabilitation (on the average 20 days of the procedures) and 3 months afterwards. The clinical examination included the measurement of muscle strength using Lovett test. It has been demonstrated that the introduction of modern highly specialized physiotherapy contributes to the improvement of the outcome and to the shortening of the treatment duration. A significant improvement was observed in all the examined patients at all stages of rehabilitation in relation to the baseline values. The conducted modern physiotherapy has a significant effect on the condition of patients after surgery. Different exercises on dynamometric platform combined with static and dynamic exercises exert a positive impact on the strengthening of muscles surrounding the knee joint, which in time perspective results in better quality of life of the patients.

  13. Subsequent Total Joint Arthroplasty After Primary Total Knee or Hip Arthroplasty

    PubMed Central

    Sanders, Thomas L.; Maradit Kremers, Hilal; Schleck, Cathy D.; Larson, Dirk R.; Berry, Daniel J.

    2017-01-01

    Background: Despite the large increase in total hip arthroplasties and total knee arthroplasties, the incidence and prevalence of additional contralateral or ipsilateral joint arthroplasty are poorly understood. The purpose of this study was to determine the rate of additional joint arthroplasty after a primary total hip arthroplasty or total knee arthroplasty. Methods: This historical cohort study identified population-based cohorts of patients who underwent primary total hip arthroplasty (n = 1,933) or total knee arthroplasty (n = 2,139) between 1969 and 2008. Patients underwent passive follow-up through their medical records beginning with the primary total hip arthroplasty or total knee arthroplasty. We assessed the likelihood of undergoing a subsequent total joint arthroplasty, including simultaneous and staged bilateral procedures. Age, sex, and calendar year were evaluated as potential predictors of subsequent arthroplasty. Results: During a mean follow-up of 12 years after an initial total hip arthroplasty, we observed 422 contralateral total hip arthroplasties (29% at 20 years), 76 contralateral total knee arthroplasties (6% at 10 years), and 32 ipsilateral total knee arthroplasties (2% at 20 years). Younger age was a significant predictor of contralateral total hip arthroplasty (p < 0.0001), but not a predictor of the subsequent risk of total knee arthroplasty. During a mean follow-up of 11 years after an initial total knee arthroplasty, we observed 809 contralateral total knee arthroplasties (45% at 20 years), 31 contralateral total hip arthroplasties (3% at 20 years), and 29 ipsilateral total hip arthroplasties (2% at 20 years). Older age was a significant predictor of ipsilateral or contralateral total hip arthroplasty (p < 0.001). Conclusions: Patients undergoing total hip arthroplasty or total knee arthroplasty can be informed of a 30% to 45% chance of a surgical procedure in a contralateral cognate joint and about a 5% chance of a surgical procedure in noncognate joints within 20 years of initial arthroplasty. Increased risk of contralateral total knee arthroplasty following an initial total hip arthroplasty may be due to gait changes prior to and/or following total hip arthroplasty. The higher prevalence of bilateral total hip arthroplasty in younger patients may result from bilateral disease processes that selectively affect the young hip, such as osteonecrosis, or structural hip problems, such as acetabular dysplasia or femoroacetabular impingement. Level of Evidence: Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence. PMID:28244910

  14. Effect of knee joint icing on knee extension strength and knee pain early after total knee arthroplasty: a randomized cross-over study.

    PubMed

    Holm, Bente; Husted, Henrik; Kehlet, Henrik; Bandholm, Thomas

    2012-08-01

    To investigate the acute effect of knee joint icing on knee extension strength and knee pain in patients shortly after total knee arthroplasty. A prospective, single-blinded, randomized, cross-over study. A fast-track orthopaedic arthroplasty unit at a university hospital. Twenty patients (mean age 66 years; 10 women) scheduled for primary unilateral total knee arthroplasty. The patients were treated on two days (day 7 and day 10) postoperatively. On one day they received 30 minutes of knee icing (active treatment) and on the other day they received 30 minutes of elbow icing (control treatment). The order of treatments was randomized. Maximal knee extension strength (primary outcome), knee pain at rest and knee pain during the maximal knee extensions were measured 2-5 minutes before and 2-5 minutes after both treatments by an assessor blinded for active or control treatment. The change in knee extension strength associated with knee icing was not significantly different from that of elbow icing (knee icing change (mean (1 SD)) -0.01 (0.07) Nm/kg, elbow icing change -0.02 (0.07) Nm/kg, P = 0.493). Likewise, the changes in knee pain at rest (P = 0.475), or knee pain during the knee extension strength measurements (P = 0.422) were not different between treatments. In contrast to observations in experimental knee effusion models and inflamed knee joints, knee joint icing for 30 minutes shortly after total knee arthroplasty had no acute effect on knee extension strength or knee pain.

  15. Soft tissue knee contracture of the knee due to melorheostosis, treated by total knee arthroplasty.

    PubMed

    Moulder, Elizabeth; Marsh, Clayton

    2006-10-01

    Melorheostosis is a rare condition which can cause soft tissue joint contractures. We present a case of melorheostosis causing disabling knee joint contracture, treated successfully by total knee arthroplasty.

  16. Effect of surgical closing in total knee arthroplasty at flexion or extension: a prospective, randomized study.

    PubMed

    Kömürcü, Erkam; Yüksel, Halil Yalçın; Ersöz, Murat; Aktekin, Cem Nuri; Hapa, Onur; Çelebi, Levent; Akbal, Ayla; Biçimoğlu, Ali

    2014-12-01

    The aim of this study was to evaluate the effect of knee position during wound closure (flexed vs. extended) in total knee arthroplasty on knee strength and function, as determined by knee society scores and isokinetic testing of extensor and flexor muscle groups. In a prospective, randomized, double-blind trial, 29 patients were divided in two groups: for Group 1 patients, surgical closing was performed with the knee extended, and for Group 2 patients, the knee flexed at 90°. All the patients were treated with the same anaesthesia method, surgical team, surgical technique, prosthesis type, and rehabilitation process. American Knee Society Score values and knee flexion degrees were recorded. Isokinetic muscle strength measurements of both knees in flexion and extension were taken using 60° and 180°/s angular velocity. The peak torque and total work values, isokinetic muscle strength differences, and total work difference values were calculated for surgically repaired and healthy knees. No significant difference in the mean American Knee Society Score values and knee flexion degrees was observed between the two groups. However, using isokinetic evaluation, a significant difference was found in the isokinetic muscle strength differences and total work difference of the flexor muscle between the two groups when patients were tested at 180°/s. Less loss of strength was detected in the isokinetic muscle strength differences of the flexor muscle in Group 2 (-4.2%) than in Group 1 (-23.1%). For patients undergoing total knee arthroplasty, post-operative flexor muscle strength is improved if the knee is flexed during wound closure. II.

  17. No Differences Identified in Transverse Plane Biomechanics Between Medial Pivot and Rotating Platform Total Knee Implant Designs.

    PubMed

    Papagiannis, Georgios I; Roumpelakis, Ilias M; Triantafyllou, Athanasios I; Makris, Ioannis N; Babis, George C

    2016-08-01

    Total knee arthroplasties (TKAs) using well-designed, fixed bearing prostheses, such as medial pivot (MP), have produced good long-term results. Rotating-platform, posterior-stabilized (RP-PS) mobile bearing implants were designed to decrease polyethylene wear. Sagittal and coronal plane TKA biomechanics are well examined and correlated to polyethylene wear. However, limited research findings describe this relationship in transverse plane. We assumed that although axial plane biomechanics might not be the most destructive parameters on polyethylene wear, it is important to clarify their role because both joint kinematics and kinetics in all 3 planes are important input parameters for TKA wear testing (International Organization for Standardization 14243-1 and 14343-3). Our hypothesis was that transverse plane overall range of motion (ROM) and/or peak moment show differences that reflect on wear advantages when compared RP-PS implants to MP designs. Two groups (MPs = 24 and RP-PSs = 22 subjects) were examined by using 3D gait analysis. The variables were total internal-external rotation (IER) ROM and peak IER moments. No statistically significant difference was demonstrated between the 2 groups in kinetics (P = .389) or kinematics (P = .275). In the present study, no wear advantages were found between 2 TKAs. Both designs showed identical kinetics at the transverse plane in level-ground walking. Kinematic analysis could not illustrate any statistically significant difference in terms of overall IER ROM. Nevertheless, kinematic gait pattern differences observed possibly reflect different patterns of joint surface motion or abnormal gait patterns. Thus, wear testing with various input waveforms combined with functional data analysis will be necessary to identify the actual effects of gait variability on polyethylene wear. Copyright © 2016 Elsevier Inc. All rights reserved.

  18. Intra-operative periarticular multimodal injection in total knee arthroplasty: a local hospital experience in Hong Kong.

    PubMed

    Fan, J Ch

    2018-04-01

    Data from a local report revealed the superior outcome of regional anaesthesia and analgesia compared with general anaesthesia and intravenous patient-controlled analgesia in total knee arthroplasty. This retrospective study aimed to assess the efficacy of intra-operative periarticular multimodal injection in improving postoperative pain and reducing morphine consumption with patient-controlled analgesia after total knee arthroplasty in patients with knee osteoarthritis. From July 2005 to May 2009, 213 total knee arthroplasties without intra-operative periarticular multimodal injection (control group) were performed at a local hospital. From June 2009 to December 2012, 185 total knee arthroplasties were performed with intra-operative periarticular multimodal injection (cocktail group). The inclusion criteria were osteoarthritis of the knee, single method of anaesthesia (general or neuraxial), simple total knee arthroplasty without any metal augmentation or constraint, and postoperative patient-controlled analgesia. Postoperative patient-controlled morphine doses were compared. A total of 152 total knee arthroplasties were recruited to the cocktail group, and 89 to the control group. Duration of tourniquet application and preoperative knee score did not significantly correlate with morphine consumption by patient-controlled analgesia. Multimodal injection significantly decreased such consumption for 36 h. When injection was separately analysed for general and neuraxial anaesthesia, the effect lasted for 42 h and 24 h, respectively. Intra-operative periarticular multimodal injection decreased morphine consumption for up to 42 h postoperatively.

  19. Relationship of unilateral total hip arthroplasty (THA) to contralateral and ipsilateral knee joint degeneration - a longitudinal 3T MRI study from the Osteoarthritis Initiative (OAI).

    PubMed

    Jungmann, P M; Nevitt, M C; Baum, T; Liebl, H; Nardo, L; Liu, F; Lane, N E; McCulloch, C E; Link, T M

    2015-07-01

    To evaluate the association of prevalent unilateral total hip arthroplasty (THA) with worsening of degenerative knee abnormalities and clinical outcomes in the ipsilateral and contralateral knee. Both knees of 30 individuals in the Osteoarthritis Initiative (OAI) with unilateral THA (n = 14 left, n = 16 right) at baseline were assessed at baseline and at 4-year follow-up for Whole-organ MR Imaging Scores (WORMS), cartilage T2 relaxation times (only available for right knees), Western Ontario and McMasters Universities Arthritis Index (WOMAC) scores and upper leg isometric strength. Right knees of 30 individuals without THA were analyzed as controls. Contralateral knees were compared to ipsilateral knees with paired t-tests and to control knees with multivariate regression analysis adjusting for covariates. In paired analyses, compared to ipsilateral knees, contralateral knees had higher WORMS total (P = 0.008) and cartilage scores (P = 0.007) at baseline. Over 4 years contralateral knees worsened more on WORMS total score (P = 0.008). Cartilage T2 values were higher in knees contralateral to the THA (baseline, P = 0.02; follow-up, P < 0.001). Contralateral knees had greater declines in knee extension strength (P = 0.04) and had a trend for greater worsening in WOMAC pain, stiffness, function and total scores (P = 0.04-0.09). Similar results were found comparing contralateral knees with control knees in multivariate regression models. Prevalent unilateral THA is associated with an greater progression of degenerative findings for the knee contralateral to THA. Copyright © 2015 Osteoarthritis Research Society International. Published by Elsevier Ltd. All rights reserved.

  20. Effect of Age on Cost-Effectiveness of Unicompartmental Knee Arthroplasty Compared with Total Knee Arthroplasty in the U.S.

    PubMed Central

    Ghomrawi, Hassan M.; Eggman, Ashley A.; Pearle, Andrew D.

    2015-01-01

    Background: Trade-offs between upfront benefits and later risk of revision of unicompartmental knee arthroplasty compared with those of total knee arthroplasty are poorly understood. The purpose of our study was to compare the cost-effectiveness of unicompartmental knee arthroplasty with that of total knee arthroplasty across the age spectrum of patients undergoing knee replacement. Methods: Using a Markov decision analytic model, we compared unicompartmental knee arthroplasty with total knee arthroplasty with regard to lifetime costs, quality-adjusted life-years (QALYs), and incremental cost-effectiveness ratios (ICERs) from a societal perspective for patients undergoing surgery at forty-five, fifty-five, sixty-five, seventy-five, or eighty-five years of age. Transition probabilities were estimated from the literature; survival, from the Swedish Knee Arthroplasty Register; and costs, from the literature and the Healthcare Cost and Utilization Project (HCUP) database. Costs and QALYs were discounted at 3.0% annually. We conducted sensitivity analyses to test the robustness of model estimates and threshold analyses. Results: For patients sixty-five years of age and older, unicompartmental knee arthroplasty dominated total knee arthroplasty, with lower lifetime costs and higher QALYs. Unicompartmental knee arthroplasty was no longer cost-effective at a $100,000/QALY threshold when total knee arthroplasty rehabilitation costs were reduced by two-thirds or more for these older patients. Lifetime societal savings from utilizing unicompartmental knee arthroplasty in all older patients (sixty-five or older) in 2015 and 2020 were $56 to $336 million and $84 to $544 million, respectively. In the forty-five and fifty-five-year-old age cohorts, total knee arthroplasty had an ICER of $30,300/QALY and $63,000/QALY, respectively. Unicompartmental knee arthroplasty became cost-effective when its twenty-year revision rate dropped from 27.8% to 25.7% for the forty-five-year age group and from 27.9% to 26.7% for the fifty-five-year age group. Conclusions: Unicompartmental knee arthroplasty is an economically attractive alternative in patients sixty-five years of age or older, and modest improvements in implant survivorship could make it a cost-effective alternative in younger patients. PMID:25740030

  1. Kinematic analysis of anterior cruciate ligament reconstruction in total knee arthroplasty

    PubMed Central

    Liu, Hua-Wei; Ni, Ming; Zhang, Guo-Qiang; Li, Xiang; Chen, Hui; Zhang, Qiang; Chai, Wei; Zhou, Yong-Gang; Chen, Ji-Ying; Liu, Yu-Liang; Cheng, Cheng-Kung; Wang, Yan

    2016-01-01

    Background: This study aims to retain normal knee kinematics after knee replacement surgeries by reconstructing anterior cruciate ligament during total knee arthroplasty. Method: We use computational simulation tools to establish four dynamic knee models, including normal knee model, posterior cruciate ligament retaining knee model, posterior cruciate ligament substituting knee model, and anterior cruciate ligament reconstructing knee model. Our proposed method utilizes magnetic resonance images to reconstruct solid bones and attachments of ligaments, and assemble femoral and tibial components according representative literatures and operational specifications. Dynamic data of axial tibial rotation and femoral translation from full-extension to 135 were measured for analyzing the motion of knee models. Findings: The computational simulation results show that comparing with the posterior cruciate ligament retained knee model and the posterior cruciate ligament substituted knee model, reconstructing anterior cruciate ligament improves the posterior movement of the lateral condyle, medial condyle and tibial internal rotation through a full range of flexion. The maximum posterior translations of the lateral condyle, medial condyle and tibial internal rotation of the anterior cruciate ligament reconstructed knee are 15.3 mm, 4.6 mm and 20.6 at 135 of flexion. Interpretation: Reconstructing anterior cruciate ligament in total knee arthroplasty has been approved to be an more efficient way of maintaining normal knee kinematics comparing to posterior cruciate ligament retained and posterior cruciate ligament substituted total knee arthroplasty. PMID:27347334

  2. Prevalence of Total Hip and Knee Replacement in the United States.

    PubMed

    Maradit Kremers, Hilal; Larson, Dirk R; Crowson, Cynthia S; Kremers, Walter K; Washington, Raynard E; Steiner, Claudia A; Jiranek, William A; Berry, Daniel J

    2015-09-02

    Descriptive epidemiology of total joint replacement procedures is limited to annual procedure volumes (incidence). The prevalence of the growing number of individuals living with a total hip or total knee replacement is currently unknown. Our objective was to estimate the prevalence of total hip and total knee replacement in the United States. Prevalence was estimated using the counting method by combining historical incidence data from the National Hospital Discharge Survey and the Healthcare Cost and Utilization Project (HCUP) State Inpatient Databases from 1969 to 2010 with general population census and mortality counts. We accounted for relative differences in mortality rates between those who have had total hip or knee replacement and the general population. The 2010 prevalence of total hip and total knee replacement in the total U.S. population was 0.83% and 1.52%, respectively. Prevalence was higher among women than among men and increased with age, reaching 5.26% for total hip replacement and 10.38% for total knee replacement at eighty years. These estimates corresponded to 2.5 million individuals (1.4 million women and 1.1 million men) with total hip replacement and 4.7 million individuals (3.0 million women and 1.7 million men) with total knee replacement in 2010. Secular trends indicated a substantial rise in prevalence over time and a shift to younger ages. Around 7 million Americans are living with a hip or knee replacement, and consequently, in most cases, are mobile, despite advanced arthritis. These numbers underscore the substantial public health impact of total hip and knee arthroplasties. Copyright © 2015 by The Journal of Bone and Joint Surgery, Incorporated.

  3. Current and innovative pain management techniques in total knee arthroplasty.

    PubMed

    Dalury, David F; Lieberman, Jay R; Macdonald, Steven J

    2012-01-01

    Pain management is a major concern for patients contemplating total knee replacement surgery and is one of the leading causes of dissatisfaction after knee replacement. Substantial progress has been made over the past several years in improving pain control after total knee replacement using multimodal pain control, preemptive analgesia, and periarticular injections.

  4. Design forms of total knee replacement.

    PubMed

    Walker, P S; Sathasivam, S

    2000-01-01

    The starting point of this article is a general design criterion applicable to all types of total knee replacement. This criterion is then expanded upon to provide more specifics of the required kinematics, and the forces which the total knee must sustain. A characteristic which differentiates total knees is the amount of constraint which is required, and whether the constraint is translational or rotational. The different forms of total knee replacement are described in terms of these constraints, starting with the least constrained unicompartments to the almost fully constrained fixed and rotating hinges. Much attention is given to the range of designs in between these two extreme types, because they constitute by far the largest in usage. This category includes condylar replacements where the cruciate ligaments are preserved or resected, posterior cruciate substituting designs and mobile bearing knees. A new term, 'guided motion knees', is applied to the growing number of designs which control the kinematics by the use of intercondylar cams or specially shaped and even additional bearing surfaces. The final section deals with the selection of an appropriate design of total knee for specific indications based on the design characteristics.

  5. Balance Training With a Dynamometric Platform Following Total Knee Replacement: A Randomized Controlled Trial.

    PubMed

    Roig-Casasús, Sergio; María Blasco, José; López-Bueno, Laura; Blasco-Igual, María Clara

    2017-03-01

    Sensorimotor training has proven to be an efficient approach for recovering balance control following total knee replacement (TKR). The purpose of this trial was to evaluate the influence of specific balance-targeted training using a dynamometric platform on the overall state of balance in older adults undergoing TKR. This was a randomized controlled clinical trial conducted at a university hospital rehabilitation unit. Patients meeting the inclusion criteria were randomly assigned to a control group or an experimental group. Both groups participated in the same 4-week postoperative rehabilitation training protocol. Participants in the experimental group performed additional balance training with a dynamometric platform consisting of tests related to stability challenges, weight-shifting, and moving to the limits of stability. The primary outcome measure was the overall state of balance rated according to the Berg Balance Scale. Secondary outcomes in terms of balance were the Timed Up and Go Test, Functional Reach Test, and Romberg open and closed-eyes tests. Data processing included between-group analysis of covariance, minimal detectable change assessment for the primary outcome measure, and effect size estimation. Confidence intervals (CIs) were set at 95%. Forty-three participants meeting the inclusion criteria and having signed the informed consent were randomly assigned to 2 groups. Thirty-seven completed the training (86.1%). Significant between-group differences in balance performance were found as measured with the Berg Balance Scale (P = .03) and Functional Reach Test (P = .04) with a CI = 95%. Significant differences were not recorded for the Timed Up and Go Test or Romberg open and closed-eyes tests (P > .05). Furthermore, Cohen's effect size resulted in a value of d = 0.97, suggesting a high practical significance of the trial. According to the Berg Balance Scale and Functional Reach Test, participants with TKR who have followed a 4-week training program using a dynamometric platform improved balance performance to a higher extent than a control group training without such a device. The inclusion of this instrument in the functional training protocol may be beneficial for recovering balance following TKR.

  6. Computer-aided diagnosis of early knee osteoarthritis based on MRI T2 mapping.

    PubMed

    Wu, Yixiao; Yang, Ran; Jia, Sen; Li, Zhanjun; Zhou, Zhiyang; Lou, Ting

    2014-01-01

    This work was aimed at studying the method of computer-aided diagnosis of early knee OA (OA: osteoarthritis). Based on the technique of MRI (MRI: Magnetic Resonance Imaging) T2 Mapping, through computer image processing, feature extraction, calculation and analysis via constructing a classifier, an effective computer-aided diagnosis method for knee OA was created to assist doctors in their accurate, timely and convenient detection of potential risk of OA. In order to evaluate this method, a total of 1380 data from the MRI images of 46 samples of knee joints were collected. These data were then modeled through linear regression on an offline general platform by the use of the ImageJ software, and a map of the physical parameter T2 was reconstructed. After the image processing, the T2 values of ten regions in the WORMS (WORMS: Whole-organ Magnetic Resonance Imaging Score) areas of the articular cartilage were extracted to be used as the eigenvalues in data mining. Then,a RBF (RBF: Radical Basis Function) network classifier was built to classify and identify the collected data. The classifier exhibited a final identification accuracy of 75%, indicating a good result of assisting diagnosis. Since the knee OA classifier constituted by a weights-directly-determined RBF neural network didn't require any iteration, our results demonstrated that the optimal weights, appropriate center and variance could be yielded through simple procedures. Furthermore, the accuracy for both the training samples and the testing samples from the normal group could reach 100%. Finally, the classifier was superior both in time efficiency and classification performance to the frequently used classifiers based on iterative learning. Thus it was suitable to be used as an aid to computer-aided diagnosis of early knee OA.

  7. Influence of hip and knee osteoarthritis on dynamic postural control parameters among older fallers.

    PubMed

    Mat, Sumaiyah; Ng, Chin Teck; Tan, Maw Pin

    2017-03-06

    To compare the relationship between postural control and knee and hip osteoarthritis in older adults with and without a history of falls. Fallers were those with ≥ 2 falls or 1 injurious fall over 12 months. Non-fallers were volunteers with no falls in the past year. Radiological evidence of osteoarthritis with no reported symptoms was considered "asymptomatic osteoarthritis", while "symptomatic osteoarthritis" was defined as radiographic osteoarthritis with pain or stiffness. Dynamic postural control was quantified with the limits of stability test measured on a balance platform (Neurocom® Balancemaster, California, USA). Parameters assessed were end-point excursion, maximal excursion, and directional control. A total of 102 older individuals, mean age 73 years (standard deviation 5.7) years were included. The association between falls and poor performance in maximal excursion and directional control was confounded by age and comorbidities. In the same linear equation model with falls, symptomatic osteoarthritis remained independently associated with poor end-point excursion (β-coefficient (95% confidence interval) -6.80 (-12.14 to -1.42)). Poor performance in dynamic postural control (maximal excursion and directional control) among fallers was not accounted for by hip/knee osteoarthritis, but was confounded by old age and comorbidities. Loss of postural control due to hip/knee osteoarthritis is not a risk factor for falls among community-dwelling older adults.

  8. Effects of early whole-body vibration treatment on knee neuromuscular function and postural control after anterior cruciate ligament reconstruction: A randomized controlled trial.

    PubMed

    Pistone, Eugenio Maria; Laudani, Luca; Camillieri, Gianluca; Di Cagno, Alessandra; Tomassi, Gabriele; Macaluso, Andrea; Giombini, Arrigo

    2016-11-11

    To assess the effects of adding a whole-body vibration protocol at optimal frequency (WBV-OF) to a traditional rehabilitation programme (TRP) early after anterior cruciate ligament reconstruction, on maximal strength and balance, in comparison with a traditional rehabilitation programme. A total of 34 anterior cruciate ligament reconstructed patients with hamstring-tendon graft underwent either 4 weeks of WBV-OF training in addition to a traditional rehabilitation programme, or a traditional rehabilitation programme only, starting from the first month after surgery. Patients were assessed for maximal voluntary isometric strength during both knee extension and flexion and for balance on a force platform before, 1 month after treatment and at 3-month follow-up. Strength symmetry of the knee flexor muscles improved in WBV-OF+TRP patients more than in TRP patients 1 month after treatment (mean 66% (standard deviation (SD) 15) vs 58% SD 13), and also at the 3-month follow-up (mean 77% (SD 15) vs 64% (SD 15)), with no differences in balance improvements between the groups. Adding 4-weeks of WBV-OF to a traditional rehabilitation programme 1 month after surgery is effective in improving muscle strength of the knee flexor muscles. This early intervention may be incorporated into current rehabilitation to facilitate early strength recovery of anterior cruciate ligament reconstructed patients.

  9. Quasi-stiffness of the knee joint in flexion and extension during the golf swing.

    PubMed

    Choi, Ahnryul; Sim, Taeyong; Mun, Joung Hwan

    2015-01-01

    Biomechanical understanding of the knee joint during a golf swing is essential to improve performance and prevent injury. In this study, we quantified the flexion/extension angle and moment as the primary knee movement, and evaluated quasi-stiffness represented by moment-angle coupling in the knee joint. Eighteen skilled and 23 unskilled golfers participated in this study. Six infrared cameras and two force platforms were used to record a swing motion. The anatomical angle and moment were calculated from kinematic and kinetic models, and quasi-stiffness of the knee joint was determined as an instantaneous slope of moment-angle curves. The lead knee of the skilled group had decreased resistance duration compared with the unskilled group (P < 0.05), and the resistance duration of the lead knee was lower than that of the trail knee in the skilled group (P < 0.01). The lead knee of the skilled golfers had greater flexible excursion duration than the trail knee of the skilled golfers, and of both the lead and trail knees of the unskilled golfers. These results provide critical information for preventing knee injuries during a golf swing and developing rehabilitation strategies following surgery.

  10. Bilateral custom-fit total knee arthroplasty in a patient with poliomyelitis.

    PubMed

    Tardy, Nicolas; Chambat, Pierre; Murphy, Colin G; Fayard, Jean-Marie

    2014-09-01

    In limbs affected by poliomyelitis, total knee arthroplasty results in satisfactory pain relief. However, the risk of failure is high, especially if the preoperative quadriceps power is low. Therefore, treating osteoarthritis in the current patient represented a challenging procedure. A 66-year-old man presented with tricompartmental osteoarthritis of both knees, with valgus deformity of 14° on the left knee and 11° on the right knee. He walked with a bilateral knee recurvatum of 30° and a grade 1 quadriceps power. The authors treated both knees with cemented custom-fit hinged total knee arthroplasty with 30° of recurvatum in the tibial keel. Clinical scores showed good results 1 year postoperatively, especially on the subjective data of quality of life and function. At follow-up, radiographs showed good total knee arthroplasty positioning on the right side and a small mechanical loosening at the end of the tibial keel on the left side. Only 5 studies (Patterson and Insall; Moran; Giori and Lewallen; Jordan et al; and Tigani et al) have reported total knee arthroplasty results in patients with poliomyelitis. This study reports an original case of bilateral custom-fit hinged total knee arthroplasty in a patient with poliomyelitis. To the authors' knowledge, this is the first report of this type of procedure in the literature. The key point is the degree of recurvatum that is needed to allow walking, avoiding excessive constraints on the implants that can lead to early mechanical failure. Copyright 2014, SLACK Incorporated.

  11. Soft-Tissue Reconstruction of the Complicated Knee Arthroplasty: Principles and Predictors of Salvage.

    PubMed

    Colen, David L; Carney, Martin J; Shubinets, Valeriy; Lanni, Michael A; Liu, Tiffany; Levin, L Scott; Lee, Gwo-Chin; Kovach, Stephen J

    2018-04-01

    Total knee arthroplasty is a common orthopedic procedure in the United States and complications can be devastating. Soft-tissue compromise or joint infection may cause failure of prosthesis requiring knee fusion or amputation. The role of a plastic surgeon in total knee arthroplasty is critical for cases requiring optimization of the soft-tissue envelope. The purpose of this study was to elucidate factors associated with total knee arthroplasty salvage following complications and clarify principles of reconstruction to optimize outcomes. A retrospective review of patients requiring soft-tissue reconstruction performed by the senior author after total knee arthroplasty over 8 years was completed. Logistic regression and Fisher's exact tests determined factors associated with the primary outcome, prosthesis salvage versus knee fusion or amputation. Seventy-three knees in 71 patients required soft-tissue reconstruction (mean follow-up, 1.8 years), with a salvage rate of 61.1 percent, mostly using medial gastrocnemius flaps. Patients referred to our institution with complicated periprosthetic wounds were significantly more likely to lose their knee prosthesis than patients treated only within our system. Patients with multiple prior knee operations before definitive soft-tissue reconstruction had significantly decreased rates of prosthesis salvage and an increased risk of amputation. Knee salvage significantly decreased with positive joint cultures (Gram-negative greater than Gram-positive organisms) and particularly at the time of definitive reconstruction, which also trended toward an increased risk of amputation. In revision total knee arthroplasty, prompt soft-tissue reconstruction improves the likelihood of success, and protracted surgical courses and contamination increase failure and amputations. The authors show a benefit to involving plastic surgeons early in the course of total knee arthroplasty complications to optimize genicular soft tissues. Therapeutic, III.

  12. Lessons learned from selective soft-tissue release for gap balancing in primary total knee arthroplasty: an analysis of 1216 consecutive total knee arthroplasties: AAOS exhibit selection.

    PubMed

    Peters, Christopher L; Jimenez, Chris; Erickson, Jill; Anderson, Mike B; Pelt, Christopher E

    2013-10-16

    Soft-tissue releases are commonly necessary to achieve symmetrical flexion and extension gaps in primary total knee arthroplasty performed with a measured resection technique. We reviewed the frequency of required releases according to preoperative alignment and the clinical and radiographic results; associations with failure, reoperations, and complications are presented. We reviewed 1216 knees that underwent primary total knee arthroplasty from 2004 to 2009; 774 (64%) were in female patients and 442 (36%), in male patients. In the coronal plane, 855 knees had preoperative varus deformity, 123 were neutral, and 238 had valgus deformity. The mean age at the time of the index procedure was 62.7 years (range, twenty-three to ninety-four years), and the mean body mass index was 32.7 kg/m² (range, 17.4 to 87.9 kg/m²). Clinical outcomes included the Knee Society Score (KSS), implant failure, reoperation, and complications. Radiographs were analyzed for component alignment. The only difference in the total KSS was found at the time of final follow-up between valgus knees with zero releases (total KSS = 178) and those with one or two releases (KSS = 160, p = 0.026). Overall, 407 knees (33.5%) required zero releases, 686 (56.4%) required one or two releases, and 123 (10.1%) required three or more releases. Among varus knees, 37% required zero releases, 55% required one or two releases, and 7.5% required three or more releases. Among neutral knees, 39% required zero releases, 55% required one or two releases, and 5.7% required three or more releases. Only 17% of valgus knees required zero releases whereas 61% required one or two releases and 21.8% required three or more releases. Valgus knees required more releases than neutral or varus knees did (p < 0.001). Selective soft-tissue release for gap balancing in primary total knee arthroplasty is an effective technique that produced excellent clinical and radiographic results regardless of preoperative alignment. Consistent anatomic coronal-plane alignment and soft-tissue balance could be achieved without bone cut modification by using measured bone resection and selective soft-tissue release.

  13. Total knee arthroplasty after high tibial osteotomy. A comparison study in patients who had bilateral total knee replacement.

    PubMed

    Meding, J B; Keating, E M; Ritter, M A; Faris, P M

    2000-09-01

    The outcome of total knee replacement after high tibial osteotomy remains uncertain. We hypothesized that the results of total knee replacement with or without a previous high tibial osteotomy are similar. The results of a consecutive series of thirty-nine bilateral total knee arthroplasties performed with cement at an average of 8.7 years after unilateral high tibial osteotomy were reviewed. There were twenty-seven men and twelve women. Preoperatively, the knee scores according to the system of the Knee Society were similar for all of the knees; however, valgus alignment and patella infera were more common in the knees with a previous high tibial osteotomy. Bilateral total knee replacement was staged in seven patients and was simultaneous in thirty-two patients. The results of the total knee arthroplasties were retrospectively reviewed with respect to the knee and function scores according to the system of the Knee Society, the radiographic findings, and the complications. Intraoperatively, no notable differences were identified in the number of medial, lateral, or lateral patellar releases required. However, less lateral tibial bone was resected in the group with a previous high tibial osteotomy (average, 3.3 millimeters) than in the group without a high tibial osteotomy (average, 7.5 millimeters). The average duration of follow-up was 7.5 years (range, three to sixteen years) in the group with a previous high tibial osteotomy and 6.8 years (range, two to ten years) in the group without a high tibial osteotomy. At the time of the final follow-up, the knee and function scores were similar for the two groups (89.0 and 81.0 points, respectively, for the group with a previous high tibial osteotomy, and 89.6 and 83.9 points, respectively, for the group without a high tibial osteotomy). Although more knees were free of pain in the group without a previous high tibial osteotomy (thirty-six) than in the group with a previous osteotomy (thirty-three), this difference was not found to be significant with the numbers available (p = 0.4810). Knee alignment and stability, femoral and tibial component alignment, and range of motion also were similar in both groups postoperatively. One allpolyethylene tibial component was revised in the high tibial osteotomy group. Two knees in each group required manipulation. There were no deep infections. While patients with a previous high tibial osteotomy may have important differences preoperatively, including valgus alignment, patella infera, and decreased bone stock in the proximal part of the tibia, the present study suggests that the clinical and radiographic results of primary total knee arthroplasty in knees with and without a previous high tibial osteotomy are not substantially different. In our relatively small group of patients, the previous high tibial osteotomy had no adverse effect on the outcome of the subsequent total knee replacement.

  14. [Prevention and repair of patellar ligament injury in total knee arthroplasty].

    PubMed

    Bian, Yanyan; Weng, Xisheng

    2013-09-01

    To review the progress in the prevention and repair of patellar ligament injury in total knee Recent literature about the prevention and repair of patellar ligament injury in total knee arthroplasty arthroplasty. was reviewed and analyzed. Increased exposure can prevent the patellar ligament injury, and treatments of acute patellar ligament rupture can be obtained by simple repair, reconstruction with allograft materials or artificial materials, and auxiliary strengthening. Patellar ligament injury in total knee arthroplasty should not be ignored. Active prevention and repair of patellar ligament injury can obtain better function of knee joint.

  15. Joint Line Reconstruction in Navigated Total Knee Arthroplasty Revision

    ClinicalTrials.gov

    2012-05-16

    Revision Total Knee Arthroplasty Because of; Loosening; Instability; Impingement; or Other Reasons Accepted as Indications for TKA Exchange.; The Focus is to Determine the Precision of Joint Line Restoration in Navigated vs. Conventional Revision Total Knee Arthroplasty

  16. Radiologic changes of ankle joint after total knee arthroplasty.

    PubMed

    Lee, Jung Hee; Jeong, Bi O

    2012-12-01

    The authors noticed that ankle joint osteoarthritis was not uncommon when lower extremity malalignment, such as a knee varus deformity, was present as a result of severe osteoarthritis of the knee. The purpose of this study was to analyze radiologic changes of the ankle joint after total knee arthroplasty. This study included 142 cases in 110 patients who underwent total knee arthroplasty and were followed for at least 3 years. The varus knee group included 128 cases and the valgus knee group included 14 cases. On anteroposterior standing lower extremity radiographs, varus and valgus angles of the knee were measured preoperatively and at the last follow-up. The angle between the ground surface and the distal tibial plafond as well as the upper talus was also measured. In addition, tibial anterior surface angle, talar tilt, space between the medial malleolar distal tip and the medial articular surface of the talus, and medial tibiotalar joint space of the ankle joint were measured. Out of 142 cases, 50 (35.2%) had arthritis in the ankle before total knee arthroplasty and 31 (21.8%) had newly developed or progressive arthritis after surgery. In particular, the varus knee group demonstrated statistically significant differences in preoperative varus deformity, preoperative talar tilt, and postoperative correction angle between the cases that developed or had progressive arthritis and those that did not show any changes (p < .05). After total knee arthroplasty, arthritis developed or progressed in the ankle of many cases radiographically. In particular, when the preoperative talar tilt increased medial to the ankle or the postoperative correction angle was large, the incidence of arthritis in the ankle joint increased. The authors recommend more cautious follow-up on the symptoms of the ankle joint after total knee arthroplasty.

  17. Failure of aseptic revision total knee arthroplasties

    PubMed Central

    Leta, Tesfaye H; Lygre, Stein Håkon L; Skredderstuen, Arne; Hallan, Geir; Furnes, Ove

    2015-01-01

    Background and purpose In Norway, the proportion of revision knee arthroplasties increased from 6.9% in 1994 to 8.5% in 2011. However, there is limited information on the epidemiology and causes of subsequent failure of revision knee arthroplasty. We therefore studied survival rate and determined the modes of failure of aseptic revision total knee arthroplasties. Method This study was based on 1,016 aseptic revision total knee arthroplasties reported to the Norwegian Arthroplasty Register between 1994 and 2011. Revisions done for infections were not included. Kaplan-Meier and Cox regression analyses were used to assess the survival rate and the relative risk of re-revision with all causes of re-revision as endpoint. Results 145 knees failed after revision total knee arthroplasty. Deep infection was the most frequent cause of re-revision (28%), followed by instability (26%), loose tibial component (17%), and pain (10%). The cumulative survival rate for revision total knee arthroplasties was 85% at 5 years, 78% at 10 years, and 71% at 15 years. Revision total knee arthroplasties with exchange of the femoral or tibial component exclusively had a higher risk of re-revision (RR = 1.7) than those with exchange of the whole prosthesis. The risk of re-revision was higher for men (RR = 2.0) and for patients aged less than 60 years (RR = 1.6). Interpretation In terms of implant survival, revision of the whole implant was better than revision of 1 component only. Young age and male sex were risk factors for re-revision. Deep infection was the most frequent cause of failure of revision of aseptic total knee arthroplasties. PMID:25267502

  18. Arthrodesis Using Pedicled Fibular Flap After Failed Infected Knee Arthroplasty

    PubMed Central

    Minear, Steve C.; Lee, Gordon; Kahn, David; Goodman, Stuart

    2011-01-01

    Objective: Severe bone loss associated with failed revision total knee arthroplasty is a challenging scenario. The pedicled fibular flap is a method to obtain vascularized bone for use in knee arthrodesis after failure of a total knee arthroplasty, with substantial loss of bone. Methods: We report 2 successful knee arthrodeses using this method in patients with infected, failed multiply revised total knee arthroplasties. The failed prosthesis was removed, and the bones were aligned and stabilized. The fibular flap was then harvested, fed through a subcutaneous tunnel, and placed within the medullary canal at the arthrodesis site. The soft tissue was closed over the grafts and flaps. Results: Two elderly women presented with pain and drainage from previous total knee arthroplasties after multiple revisions. Arthrodeses were performed as described, and both patients were pain-free with the knee fused at 1 year. Conclusions: Thus, pedicled vascularized flaps are a viable alternative in the treatment of failed revision arthroplasty with large segmental bone loss. PMID:22132250

  19. Extra-articular deformity correction using Taylor spatial frame prior to total knee arthroplasty.

    PubMed

    Tawari, Gautam J K; Maheshwari, Rajan; Madan, Sanjeev S

    2018-03-20

    A good long-term outcome following a total knee arthroplasty relies on restoration of the mechanical axis and effective soft tissue balancing of the prosthetic knee. Arthroplasty surgery in patients with secondary osteoarthritis of the knee with an extra-articular tibial deformity is a complex and challenging procedure. The correction of mal-alignment of the mechanical axis is associated with unpredictable result and with higher revision rates. Single-staged deformity correction and replacement surgery often result in the use of constraint implants. We describe our experience with staged correction of deformity using a Taylor Spatial Frame (TSF) followed by total knee arthroplasty in these patients and highlight the advantage of staged approach. The use of TSF fixator for deformity correction prior to a primary total knee arthroplasty has not been described in the literature. We describe three cases of secondary osteoarthritis of the knee associated with multiplanar tibial deformity treated effectively with a total knee arthroplasty following deformity correction and union using a TSF. All patients had an improved Knee Society score and Oxford Knee score postoperatively and were satisfied with their replacement outcome. Staged deformity correction followed by arthroplasty allows the use of standard primary arthroplasty implants with predicable results and flexible aftercare. This approach may also provide significant improvement of patient symptoms following correction of deformity resulting in deferment of the arthroplasty surgery.

  20. Evaluation of a knee-kicker bumper design for reducing knee morbidity among carpet layers.

    PubMed

    Huang, Wan-Fu; Wu, Chih-Fu

    2012-09-01

    Carpet layers have a high prevalence of occupational knee morbidity. One of the main causes is that they need to frequently 'kick' the bumper on the rear end of the knee kicker with one knee when laying a carpet. Considering the bumper's marked effects on kicking force transmission and safety, this study aims to improve the design of the knee-kicker bumper by reducing the risk factors. An improved pendulum-type impact-testing platform was designed as an evaluative apparatus, with the impulse and the coefficient of restitution serving as evaluative criteria. The newly developed bumper has improved firmness from drilled blind holes and an increase in effective forward force of 15%-138%, which implies lower operational demands and a lighter knee burden (i.e., less kicking energy results in the same work efficiency), and a softer contact surface that enhances operating comfort. The newly designed kicker was positively reviewed by subjects. Crown Copyright © 2012. Published by Elsevier Ltd. All rights reserved.

  1. Total knee arthroplasty in patients with a prior fracture of the tibial plateau.

    PubMed

    Weiss, Nicholas G; Parvizi, Javad; Trousdale, Robert T; Bryce, Rex D; Lewallen, David G

    2003-02-01

    A fracture of the tibial plateau may predispose the knee to the development of posttraumatic arthritis. Malunion, intra-articular chondro-osseous defects, limb malalignment, retained internal fixation devices, and poor surrounding soft tissues may in turn compromise the outcome of total knee arthroplasty. The aim of our study was to evaluate the results of total knee arthroplasty in patients with a previous fracture of the tibial plateau. The results of sixty-two condylar total knee arthroplasties performed with cement, from 1988 to 1999, in sixty-two patients with a previous fracture of the tibial plateau were reviewed. The fracture of the tibial plateau had been treated by open reduction and internal fixation in thirty-eight knees, external fixation in one knee, and nonoperatively in twenty-three knees. There were forty women and twenty-two men with an average age of sixty-three years at the time of the arthroplasty. Knee Society scores were recorded preoperatively and at the time of follow-up, at an average of 4.7 years, and complications were noted. No patient was lost to follow-up. The mean Knee Society scores improved significantly (p < 0.0001), from 43.9 points for pain and 52 points for function preoperatively to 82.9 and 84 points, respectively, at the time of the latest follow-up. There were thirteen reoperations, which included manipulation with the patient under anesthesia (five knees), wound revision (three knees), and component revision (five knees). There were six intraoperative complications (10%). A postoperative complication occurred in sixteen knees (26%). The vast majority of patients treated with total knee arthroplasty after a previous fracture of the tibial plateau have substantial improvement in function and relief of pain. However, these patients are at increased risk for perioperative complications, as evidenced by the high reoperation rate of 21% in this study.

  2. Initial experience with custom-fit total knee replacement: intra-operative events and long-leg coronal alignment.

    PubMed

    Spencer, Brian A; Mont, Michael A; McGrath, Mike S; Boyd, Bradley; Mitrick, Michael F

    2009-12-01

    New technology using magnetic resonance imaging (MRI) allows the surgeon to place total knee replacement components into each patient's pre-arthritic natural alignment. This study evaluated the initial intra-operative experience using this technique. Twenty-one patients had a sagittal MRI of their arthritic knee to determine component placement for a total knee replacement. Cutting guides were machined to control all intra-operative cuts. Intra-operative events were recorded and these knees were compared to a matching cohort of the senior surgeon's previous 30 conventional total knee replacements. Post-operative scanograms were obtained from each patient and coronal alignment was compared to previous studies using conventional and computer-assisted techniques. There were no intra-operative or acute post-operative complications. There were no differences in blood loss and there was a mean decrease in operative time of 14% compared to a cohort of patients with conventional knee replacements. The average deviation from the mechanical axis was 1.2 degrees of varus, which was comparable to previously reported conventional and computer-assisted techniques. Custom-fit total knee replacement appeared to be a safe procedure for uncomplicated cases of osteoarthritis.

  3. Influence of posterior condylar offset on knee flexion after cruciate-sacrificing mobile-bearing total knee replacement: a prospective analysis of 410 consecutive cases.

    PubMed

    Bauer, T; Biau, D; Colmar, M; Poux, X; Hardy, P; Lortat-Jacob, A

    2010-12-01

    The range of motion of the knee joint after Total Knee Replacement (TKR) is a factor of great importance that determines the postoperative function of patients. Much enthusiasm has been recently directed towards the posterior condylar offset with some authors reporting increasing postoperative knee flexion with increasing posterior condylar offset and others who did not report any significant association. Patients undergoing primary total knee replacement were included in a prospective multicentre study and the effect of the posterior condylar offset on the postoperative knee flexion was assessed after adjusting for known influential factors. All knees were implanted by three senior orthopedist surgeons with the same cemented cruciate-sacrificing mobile-bearing implant and with identical surgical technique. Clinical data, active knee flexion and posterior condylar offset were recorded preoperatively and postoperatively at a minimal one year follow-up for all patients. Univariate and multivariate linear models were fitted to select independent predictors of the postoperative knee flexion. Four hundred and ten consecutive total knee replacements (379 patients) were included in the study. The mean preoperative knee flexion was 112°. The mean condylar offset was 28.3mm preoperatively and 29.4mm postoperatively. The mean postoperative knee flexion was 108°. No correlation was found between the posterior condylar offset or the tibial slope and the postoperative knee flexion. The most significant predictive factor for postoperative flexion after posterior-stabilized TKR without PCL retention was the preoperative range of flexion, with a linear effect. Copyright © 2009 Elsevier B.V. All rights reserved.

  4. [The application of electroacupuncture to postoperative rehabilitation of total knee replacement].

    PubMed

    Chen, Gang; Gu, Rui-Xin; Xu, Dan-Dan

    2012-04-01

    To explore the effect of electroacupuncture therapy for postoperative rehabilitation of total knee replacement of knee osteoarthritis. Seventy cases of total knee replacement of knee osteoarthritis were randomly divided into an acupuncture-rehabilitation group and a rehabilitation group, thirty five cases in each group. In acupuncture-rehabilitation group, routine rehabilitation therapy combined with electroacupuncture therapy was applied. The acupoints selection was mainly based on pathological location; Xuehai (SP 10), Liangqiu (ST 34), Dubi (ST 35), Neixiyan (EX-LE 4) and Yanglingquan (GB 34), etc. were selected. In rehabilitation group, routine rehabilitation therapy was applied. The functions of affected knee in both groups were evaluated by artificial total knee replacement scale of the New York Hospital for Special Surgery (HSS), range of motion (ROM) of affected knee, Visual Analogue Scale (VAS) of pain and Manual Muscle Test (MMT) before, and 2, 6 and 12 weeks after surgery. HSS scores in acupuncture-rehabilitation group were markedly higher than those in rehabilitation group in 2, 6 and 12 weeks after surgery (P < 0.05, P < 0.01); VAS scores in acupuncture-rehabilitation group were markedly lower than those in rehabilitation group (P < 0.05, P < 0.01); ROM and MMT in acupuncture-rehabilitation group were little superior to those in rehabilitation group, however, there was no significant difference (all P > 0.05). Rehabilitation therapy combined with electroacupuncture can obviously restrain the pain during rehabilitation process for total knee replacement patients, improve the endurance capacity of rehabilitation training and motivation, and obviously promote the recovery of total knee joint function.

  5. Outcomes of Total Knee Arthroplasty in Patients With Poliomyelitis.

    PubMed

    Gan, Zhi-Wei Jonathan; Pang, Hee Nee

    2016-11-01

    We report our experience with outcomes of poliomyelitis in the Asian population. Sixteen total knee replacements in 14 patients with polio-affected knees were followed up for at least 18 months. Follow-up assessment included scoring with the American Knee Society Score (AKSS), Oxford knee score, and Short Form 36 Health Survey scores. The mean AKSS improved from 25.59 preoperatively to 82.94 at 24 months, with greater improvement in the knee score. The mean Oxford knee score improved from 40.82 preoperatively to 20.53 at 24 months. The mean AKSS pain score rose from 2.35 to 47.66 at 24 months. The Short Form 36 Health Survey physical functioning and bodily pain scores improved for all patients. Primary total knee arthroplasty of poliomyelitis-affected limbs shows good outcomes, improving quality of life, and decreasing pain. Copyright © 2016 Elsevier Inc. All rights reserved.

  6. Analysis of the lateral push-off in the freestyle flip turn.

    PubMed

    Araujo, Luciana; Pereira, Suzana; Gatti, Roberta; Freitas, Elinai; Jacomel, Gabriel; Roesler, Helio; Villas-Boas, Joao

    2010-09-01

    The aim of this study was to examine the contact phase during the lateral push-off in the turn of front crawl swimming to determine which biomechanical variables (maximum normalized peak force, contact time, impulse, angle of knee flexion, and total turn time within 15 m) contribute to the performance of this turn technique. Thirty-four swimmers of state, national, and international competitive standard participated in the study. For data collection, the following equipment was used: an underwater force platform, a 30-Hz VHS video camera, and a MiniDv digital camera within an underwater box. Data are expressed as descriptive statistics. Inferential analyses were performed using Pearson's correlation and multiple linear regressions. All variables studied had a significant relationship with turn performance. We conclude that a turn executed with a knee flexion angle of between 100° and 120° provides optimum peak forces to generate impulses that allow the swimmer to lose less time in the turn without the need for an excessive force application and with less energy lost.

  7. The Influence Of Component Alignment On The Life Of Total Knee Prostheses

    NASA Astrophysics Data System (ADS)

    Bugariu, Delia; Bereteu, Liviu

    2012-12-01

    An arthritic knee affects the patient's life by causing pain and limiting movement. If the cartilage and the bone surfaces are severely affected, the natural joint is replaced with an artificial joint. The procedure is called total knee arthroplasty (TKA). Lately, the numbers of implanted total knee prostheses grow steadily. An important factor in TKA is the perfect alignment of the total knee prosthesis (TKP) components. Component misalignment can lead to the prosthesis loss by producing wear particles. The paper proposes a study on mechanical behaviors of a TKP based on numerical analysis, using ANSYS software. The numerical analysis is based on both the normal and the changed angle of the components alignment.

  8. Multi-ligament instability after early dislocation of a primary total knee replacement - case report.

    PubMed

    Sisak, Krisztian; Lloyd, John; Fiddian, Nick

    2011-01-01

    Peripheral nerve blocks have found increased popularity in providing prolonged post-operative analgesia following total knee replacement surgery. They generally provide effective analgesia with fewer complications than epidurals. This report describes an acute low-energy knee dislocation after a well balanced, fixed bearing, cruciate-retaining primary total knee replacement performed under a spinal anaesthetic with combined complimentary femoral and sciatic nerve blocks. The dislocation was not accompanied by neurovascular compromise. Due to the subsequent instability and injury to both collaterals, the posterior cruciate ligament and posterolateral corner structures, the knee was treated with a rotating-hinge revision total knee replacement. The dislocation occurred whilst the peripheral nerve blocks (PNB) were still working. We review our incidence of PNB related complications and conclude that PNB remain a safe and effective analgesia for total knee replacements. However, we advocate that ward staff and patients should be sufficiently educated to ensure that unaided post-operative mobilisation is prevented until such a time that patients have regained complete voluntary muscle control. Copyright © 2009 Elsevier B.V. All rights reserved.

  9. Improvements in knee biomechanics during walking are associated with increased physical activity after total knee arthroplasty.

    PubMed

    Arnold, John B; Mackintosh, Shylie; Olds, Timothy S; Jones, Sara; Thewlis, Dominic

    2015-12-01

    Total knee arthroplasty (TKA) in people with knee osteoarthritis increases knee-specific and general physical function, but it has not been established if there is a relationship between changes in these elements of functional ability. This study investigated changes and relationships between knee biomechanics during walking, physical activity, and use of time after TKA. Fifteen people awaiting TKA underwent 3D gait analysis before and six months after surgery. Physical activity and use of time were determined in free-living conditions from a high resolution 24-h activity recall. After surgery, participants displayed significant improvements in sagittal plane knee biomechanics and improved their physical activity profiles, standing for 105 more minutes (p=0.001) and performing 64 min more inside chores on average per day (p=0.008). Changes in sagittal plane knee range of motion (ROM) and peak knee flexion positively correlated with changes in total daily energy expenditure, time spent undertaking moderate to vigorous physical activity, inside chores and passive transport (r=0.52-0.66, p=0.005-0.047). Restoration of knee function occurs in parallel and is associated with improvements in physical activity and use of time after TKA. Increased functional knee ROM is required to support improvements in total and context specific physical activity. © 2015 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  10. The trivector approach for minimally invasive total knee arthroplasty: a technical note.

    PubMed

    Benazzo, Francesco; Rossi, Stefano Marco Paolo

    2012-09-01

    One of the main criticisms of minimally invasive approaches in total knee arthroplasty has been their poor adaptability in cases of major deformity or stiffness of the knee joint. When they are used in such cases, excessive soft-tissue tension is needed to provide appropriate joint exposure. Here, we describe the "mini trivector approach," which has become our standard approach for total knee replacement because it permits us to enlarge the indication for minimally or less invasive total knee replacement to many knees where quad sparing, a subvastus approach, or a mini quad or mini midvastus snip may not be sufficient to achieve correct exposure. It consists of a limited double snip of the VMO and the quadriceps tendon that reduces tension on the extensor mechanism and allows easier verticalization of the patella as well as good joint exposure.

  11. Evaluation of total knee mechanics using a crouching simulator with a synthetic knee substitute.

    PubMed

    Lowry, Michael; Rosenbaum, Heather; Walker, Peter S

    2016-05-01

    Mechanical evaluation of total knees is frequently required for aspects such as wear, strength, kinematics, contact areas, and force transmission. In order to carry out such tests, we developed a crouching simulator, based on the Oxford-type machine, with novel features including a synthetic knee including ligaments. The instrumentation and data processing methods enabled the determination of contact area locations and interface forces and moments, for a full flexion-extension cycle. To demonstrate the use of the simulator, we carried out a comparison of two different total knee designs, cruciate retaining and substituting. The first part of the study describes the simulator design and the methodology for testing the knees without requiring cadaveric knee specimens. The degrees of freedom of the anatomic hip and ankle joints were reproduced. Flexion-extension was obtained by changing quadriceps length, while variable hamstring forces were applied using springs. The knee joint was represented by three-dimensional printed blocks on to which the total knee components were fixed. Pretensioned elastomeric bands of realistic stiffnesses passed through holes in the block at anatomical locations to represent ligaments. Motion capture of the knees during flexion, together with laser scanning and computer modeling, was used to reconstruct contact areas on the bearing surfaces. A method was also developed for measuring tibial component interface forces and moments as a comparative assessment of fixation. The method involved interposing Tekscan pads at locations on the interface. Overall, the crouching machine and the methodology could be used for many different mechanical measurements of total knee designs, adapted especially for comparative or parametric studies. © IMechE 2016.

  12. Effects of bariatric surgery for knee complaints in (morbidly) obese adult patients: a systematic review.

    PubMed

    Groen, V A; van de Graaf, V A; Scholtes, V A B; Sprague, S; van Wagensveld, B A; Poolman, R W

    2015-02-01

    Obesity is a major risk factor for the development of knee osteoarthritis, and over the past 30 years the prevalence of obesity has more than doubled. In an advanced-stage knee osteoarthritis is treated with total knee arthroplasty, and the demand for primary total knee arthroplasties is expected to grow exponentially. However, total knee arthroplasty in obese patients is associated with more complications, longer hospital stay and higher costs. We aimed to determine the effects of bariatric surgery on knee complaints in (morbidly) obese (body mass index >30 kg m(-2) ) adult patients. The Cochrane Central Register of Controlled Trials, MEDLINE, EMBASE, TRIP, BIOSIS-Previews and reference lists of retrieved publications were systematically searched from earliest available up to 20 April 2014 for any English, German, French and Dutch studies. There was no restriction on study design. We included studies on the effect of surgically induced weight reduction on knee complaints in (morbidly) obese adult patients, with a minimal follow-up of 3 months. Studies on the effects of lipectomy or liposuction and studies in which patients had already received a total knee arthroplasty were excluded. Thirteen studies were included in this systematic review with a total of 3,837 patients. Although different assessment tools were used, an overall significant improvement in knee pain was seen in 73% out of the used assessments. All studies measuring intensity of knee pain, knee physical function and knee stiffness showed a significant improvement after bariatric surgery. The quality of evidence was very low or too low for most of the included studies and moderate for one study. Bariatric surgery with subsequent marked weight loss is likely to improve knee pain, physical function and stiffness in (morbidly) obese adult patients. However, with the current available evidence, there is need for high-quality studies. © 2014 World Obesity.

  13. [Clinical effect of total knee arthroplasty on patients with knee osteoarthritis combined with mild to moderate valgus knee deformity].

    PubMed

    Chen, Peng; Zeng, Min; Xie, Jie; Wang, Long; Su, Weiping; Hu, Yihe

    2016-09-28

    To investigate the clinical effect of total knee arthroplasty on patients with knee osteoarthritis combined with mild to moderate valgus knee deformity.
 A total of 15 patients received total knee arthroplasty for correcting mild (10°-15°) to moderate (15°-30°) valgus knee between January 2011 and February 2014 in Xiangya Hospital of Central South University. We adopted a stable prosthesis surgery through patellar medial approach, osteophytes cleaning, conventional osteotomy, a selective soft tissue release and balance technical correcting of knee valgus deformity. Then conventional anticoagulation and symptomatic rehabilitation was utilized. Preoperative and postoperative X-ray was conducted in patients with measuring femor-tibial angle (FTA) and inspecting the prosthesis position. FTA, visual analog scale (VAS) standard, and parallel knee scoring system (KSS) were used to evaluate the clinical effect.
 Fifteen patients were followed up for 14 to 36 (22.40±11.88) months. The hospitalization time was 7-13 (7.73±1.58) d; operative time was 58-110 (81.8±16.85) min, the dominant blood loss was 140-600 (337.30±143.65) mL. Two cases had knee extension hysteresis, and the knee activity recovered after exercise. Leg power lines were normal. Three postoperative cases suffered anterior knee pain. They were subjected to celecoxib analgesic treatment and the pain gradually eased after 3 months. One postoperative case showed incision discharge and swelling, which was healed after change of dressing. During follow-up, review of X-ray film does not show prosthesis loose, subsidence and other complications. The knee valgus angle (8.1±1.8)°, knee motion range (107.33±9.61)°, KSS knee score (74.7±14.5, 75.3±2.7) and pain score (2.5±0.9) were significantly better than the preoperative (P<0.05). The clinical and function KSS scores showed that the improvement rate was 80%. 
 Total knee arthroplasty is an effective way to treat patients with knee osteoarthritis combined with mild to moderate valgus knee deformity. The correction of deformity and improvement of joint function can be achieved significantly. The clinical result is satisfactory and patients' quality of life is improved.

  14. Gender Differences among Sagittal Plane Knee Kinematic and Ground Reaction Force Characteristics during a Rapid Sprint and Cut Maneuver

    ERIC Educational Resources Information Center

    James, C. Roger; Sizer, Phillip S.; Starch, David W.; Lockhart, Thurmon E.; Slauterbeck, James

    2004-01-01

    Women are more prone to anterior cruciate ligament (ACL) injury during cutting sports than men. The purpose of this study was to examine knee kinematic and ground reaction forces (GRF) differences between genders during cutting. Male and female athletes performed cutting trials while force platform and video data were recorded (180 Hz).…

  15. [Meta analysis of three-dimensional printing patient-specific instrumentation versus conventional instrumentation in total knee arthroplasty].

    PubMed

    Ren, J T; Xu, C; Wang, J S; Liu, X L

    2017-10-01

    Objective: To evaluate the effects of three-dimensional printing patient-specific instrumentation(PSI) versus conventional instrumentation(CI) in the total knee arthroplasty. Methods: According to "patient-specific" , "patient-matched" , "custom" , "Instrumentation" , "Guide Instrumentation" , "cutting blocks" , "total knee arthroplasty" , "total knee replacement" , "TKA" and "TKR" , the literature on PubMed, EMbase, Cochrane library, CBM and WanFang were searched. According to the inclusion and exclusion criteria, the high quality randomized control trial (RCT) studies about three-dimensional (3D) printing patient-specific instrumentation versus conventional instrumentation in the total knee arthroplasty were collected. The post-operative limb mechanical axis outlier, the position of the components outlier, post-operative knee function, operative time, post-operative blood transfusion and complications were analyzed by RevMan 5.3 software. Results: A total of 13 high quality RCT studies were included. The results of Meta-analysis show that there were no statistical differences in the post-operative limb mechanical axis outlier( Z =0.55, P =0.58, 95% CI: 0.78 to 1.56), femoral coronal component outlier( Z =0.38, P =0.71, 95% CI: 0.69 to 1.72), tibia coronal component outlier( Z =1.95, P =0.05, 95% CI: 1.00 to 3.38), femoral rotation angle outlier( Z =0.36, P =0.72, 95% CI: 0.49 to 1.64), post-operative knee function( Z =1.18, P =0.24, 95% CI : -0.66 to 2.63), post-operative blood transfusions( Z =0.74, P =0.46, 95% CI: -0.10 to 0.05) and complications( Z =0.18, P =0.86, 95% CI: -0.07 to 0.05) between the PSI group and the CI group. But there are statistical differences in the operation time( Z =2.66, P =0.01, 95% CI: -15.97 to -2.41)and tibia sagittal component outlier ( Z =3.69, P =0.00, 95% CI: 1.43 to 3.18)between the PSI group and the CI group. Conclusions: In the primary total knee arthroplasty the PSI is not superior over the CI for the knee without severe knee varus or valgus deformity or contracture deformity, without the deformity around the knee and without the knee bone loss and obesity. The use of PSI in the primary total knee arthroplasty are not recommend.

  16. Correcting deformity in total knee arthroplasty: Techniques to avoid the release of collateral ligaments in severely deformed knees.

    PubMed

    Mullaji, A B; Shetty, G M

    2016-01-01

    Collateral ligament release is advocated in total knee arthroplasty (TKA) to deal with significant coronal plane deformities, but is also associated with significant disadvantages. We describe steps to avoid release of the collateral (superficial medial and lateral collateral) ligaments during TKA in severely deformed knees, while correcting deformity and balancing the knee. ©2016 The British Editorial Society of Bone & Joint Surgery.

  17. [Arthrodesis following revision of a knee endoprosthesis. Literature review 1984-1994].

    PubMed

    Kohn, D; Schmolke, S

    1996-04-01

    Two percent of primary and 8% of revision total knee replacements are followed by arthrodesis. Today knee arthrodesis is the most important salvage procedure after failed total knee arthroplasty, resection arthroplasty and above-the-knee amputation being the only alternatives. Analysis of the literature between 1984 and 1994 revealed 533 cases treated with arthrodesis of the knee; 403 were done after failed total knee arthroplasty. The fusion rate was 74%. External fixation, intramedullary nail, plates and combinations of these are currently used for fixation. The literature and an analysis of our own patients from 1988 to 1994 showed that arthrodesis after failed arthroplasty is a difficult procedure, and complications often occur. Bone loss of the distal femur and proximal tibia is the one most important prognostic factor. A new classification system for bone loss is presented.

  18. Effect of Tibial Posterior Slope on Knee Kinematics, Quadriceps Force, and Patellofemoral Contact Force After Posterior-Stabilized Total Knee Arthroplasty.

    PubMed

    Okamoto, Shigetoshi; Mizu-uchi, Hideki; Okazaki, Ken; Hamai, Satoshi; Nakahara, Hiroyuki; Iwamoto, Yukihide

    2015-08-01

    We used a musculoskeletal model validated with in vivo data to evaluate the effect of tibial posterior slope on knee kinematics, quadriceps force, and patellofemoral contact force after posterior-stabilized total knee arthroplasty. The maximum quadriceps force and patellofemoral contact force decreased with increasing posterior slope. Anterior sliding of the tibial component and anterior impingement of the anterior aspect of the tibial post were observed with tibial posterior slopes of at least 5° and 10°, respectively. Increased tibial posterior slope contributes to improved exercise efficiency during knee extension, however excessive tibial posterior slope should be avoided to prevent knee instability. Based on our computer simulation we recommend tibial posterior slopes of less than 5° in posterior-stabilized total knee arthroplasty. Copyright © 2015 Elsevier Inc. All rights reserved.

  19. Profix cemented total knee replacement: a 5-year outcome review from Lagos, Nigeria.

    PubMed

    Ugbeye, M E; Odunubi, O O; Dim, E M; Ekundayo, O O

    2012-01-01

    Total knee replacement is a standard treatment for severe osteoarthritis of the knees. It is however, still a novel procedure in Nigeria. Literature on the procedure and outcome of management are sparse in Nigeria. This study aimed at describing Total Knee prosthetic Replacement as it is practiced in National Orthopaedic Hospital, Lagos. Data on patients treated with Total knee replacement between 2006 and 2010 were analyzed retrospectively. The standard anterior approach, with a medial parapatellar incision under pneumatic tourniquet was used in all cases. There were a total of 59 knees in 48 patients operated, with a female: male ratio of 5:1. Patients were in the sixth to ninth decades of life. There was a statistically significant relationship between duration of symptoms and severity of angular deformity. The average pre-operative Knee score (KS) was 27 and average function score (FS) was 43. Average duration of surgery was 126.38 minutes. Tourniquet removal after wound closure was associated with reduced intra-operative blood loss (p < 0.05). Post-operative complications included peri-prosthetic fracture (1.69%), post-operative anaemia (8.47%), superficial wound dehiscence (3.39%) and foot drop (3.39%). The mean post-operative KS and FS increased to 80 and 75 respectively. Total knee replacement, though a novel procedure in our institution is beneficial to patients with severe osteoarthritis. A long term outcome study is being planned.

  20. Custom-fit total knee arthroplasty: our initial experience with 30 knees.

    PubMed

    Bonicoli, Enrico; Andreani, Lorenzo; Parchi, Paolo; Piolanti, Nicola; Lisanti, Michele

    2014-10-01

    We report our initial experience of total knee arthroplasty (TKA) using customized cutting block technology in 30 TKAs from December 2010 to September 2012. Customized blocks were generated for each of the knees using preoperative magnetic resonance imaging of knee and long-leg weight-bearing radiographs. At 30 days, long-leg radiographs were obtained to evaluate the coronal alignment. Twenty-six of the 30 knees had a mechanical axis restored to within 3° of neutral. We conclude that this technology can be safely used in most of the cases of osteoarthritis.

  1. A Comparison of Two Surgical Techniques Using the Unity Knee™ Total Knee System

    ClinicalTrials.gov

    2018-04-24

    Osteoarthritis, Knee; Rheumatoid Arthritis; Post-Traumatic Osteoarthritis of Knee; Varus Deformity, Not Elsewhere Classified, Knee; Valgus Deformity, Not Elsewhere Classified, Knee; Flexion Deformity, Knee; Fracture of Distal End of Femur; Fracture of Upper End of Tibia

  2. Design comparison: manipulation after total knee arthroplasty.

    PubMed

    Rogers, Jason M; Patel, Kevin V; Barnes, C Lowry

    2015-01-01

    Postoperative stiffness is a relatively uncommon issue in total knee arthroplasty (TKA). However, it can be a debilitating complication when it occurs. Manipulation under anesthesia (MUA) is commonly used as the primary treatment modality following failed physiotherapy. The Advance medial pivot knee (Wright Medical Technology) was created in an effort to prevent stiffness postoperatively and increase range of motion. The Evolution medial pivot knee is a second-generation design that builds on the technology of the Advance knee. This article presents a retrospective review of prospectively collected data on 881 primary medial pivot knees (592 Advance knees, 289 Evolution knees). It was theorized that the design changes made to the Evolution knees might contribute toward reducing the need for MUA. It was found that the Evolution knees required significantly fewer manipulations under anesthesia (p = .036). The design modifications made to the Evolution knees may have contributed to the lower rate of MUA.

  3. Outcome following total knee arthroplasty in obese versus non-obese Asian patients.

    PubMed

    Goh, Graham Seow-Hng; Liow, Ming Han Lincoln; Mitra, Amit Kanta

    2015-12-01

    To compare the outcome following total knee arthroplasty (TKA) in obese and non-obese Asian patients. 27 obese patients were compared with 27 non-obese controls matched for age, gender, diagnosis (osteoarthritis), prosthesis, preoperative Knee Society knee and function scores, preoperative Oxford Knee Score, and follow-up duration. All TKAs were performed by a single surgeon. Patients were assessed at 6 months and 2 years for the range of motion, Knee Society knee and function scores, Oxford Knee Score, and Short Form-36 Health Survey (SF-36). The obese and non-obese groups did not differ significantly in pre- and post-operative variables: range of motion, Knee Society knee and function scores, Oxford Knee Score, and SF-36 score. Using revision as an end-point, implant survival was 100%. There were no intra- or post-operative complications in either group. Obese and non-obese Asian patients achieved a comparable outcome following TKA.

  4. [CORRECTION OF VARUS KNEE WITH REDUCTION OSTEOTOMY DURING TOTAL KNEE ARTHROPLASTY].

    PubMed

    Su, Weiping; Xie, Jie; Li, Mingqing; Zeng, Min; Lei, Pengfei; Wang, Long; Hu, Yihe

    2015-12-01

    To evaluate the effectiveness of reduction osteotomy for correction of varus knee during total knee arthroplasty. A retrospective analysis was made on the clinical data of 16 patients (24 knees) who received reduction osteotomy for correcting varus knee during total knee arthroplasty between May 2010 and July 2012. There were 2 males (3 knees) and 14 females (21 knees), with an average age of 67 years (range, 57-79 years). The disease duration ranged from 3 to 15 years (mean, 9.1 years). The Knee Society Score (KSS) was 38.71 ± 10.04 for clinical score and 50.31 ± 14.31 for functional score. The range of motion (ROM) of the knee was (91.88 ± 13.01). The tibiofemoral angle was (9.04 ± 4.53)° of varus deformity. Reduction osteotomy was applied to correct varus knee. The operation time was 85-245 minutes (mean, 165.5 minutes); the obvious blood loss was 10-800 mL (mean, 183.1 mL); the hospitalization time was 8-22 days (mean, 13.6 days). All incisions healed by first intention. No neurovascular injury or patellar fracture occurred. The follow-up duration ranged from 37 to 62 months (mean, 48 months). The tibiofemoral angle was corrected to (3.92 ± 1.89)° of valgus at 48 hours after operation. The lower limb alignment recovered to normal. The X-ray films showed no evidence of obvious radiolucent line, osteolysis, or prosthesis subsidence. The results of KSS were significantly improved to 84.21 ± 6.49 for clinical score and 85.31 ± 6.95 for functional score (t = 20.665, P = 0.000; t = 9.585, P = 0.000); and ROM of the knee was significantly increased to (105.83 ± 11.29)° (t = 8.333, P = 0.000) at last follow-up. The effectiveness of reduction osteotomy for varus knee deformity during total knee arthroplasty is satisfactory. Proper alignment, ROM, and function of knee can be achieved.

  5. A comparison of clinical- and patient-reported outcomes of the cemented ATTUNE and PFC sigma fixed bearing cruciate sacrificing knee systems in patients who underwent total knee replacement with both prostheses in opposite knees.

    PubMed

    Carey, Brian W; Harty, James

    2018-03-15

    The ATTUNE Knee by DePuy Synthes was introduced in 2013. It is designed to provide better range of motion and address patient-reported instability. The PFC Sigma Knee, an earlier prosthesis by DePuy Synthes, is a common knee replacement with a strong clinical track record. Our aim is to compare the outcomes after primary total knee replacement for end-stage knee osteoarthritis of the PFC and ATTUNE knee systems in 21 patients who each have prosthesis in opposite knees using WOMAC, Oxford Knee and SF-12 scores and evaluation of range of motion. A review was carried out on 21 patients who underwent primary total knee replacement with both the ATTUNE and PFC knee systems. These were staged operations performed in the same institution and by the same surgeon. All cases were followed up for a minimum of 6 months. WOMAC, Oxford Knee and SF-12 scores, as well as knee range of motion were recorded preoperatively and at 6 months postoperatively. There was a significant difference in pre- to 6-month post-operative outcomes in PFC and ATTUNE groups with regard to improvement in range of motion (10° ± 8 and 13° ± 11, respectively). There was also a significant improvement in WOMAC scores (PFC group) and Oxford Knee Scores (ATTUNE group) (8.9 ± 7.7 and 12.1 ± 8.4, respectively). There was a significant improvement in SF-12 Score in both groups (10.1 ± 9.3 for PFC and 15.8 ± 13.3 for ATTUNE). The minimum clinically important difference (MCID) in scoring systems at 6 months was reached by 6 patients in the PFC group and 12 in the ATTUNE group. A significant difference was demonstrated in clinical outcome at 6 months postoperatively between PFC and ATTUNE knee systems in patients who underwent total knee arthroplasty with both prostheses. Superior results were recorded for the ATTUNE knee system.

  6. Salvage of infected total knee fusion: the last option.

    PubMed

    Wiedel, Jerome D

    2002-11-01

    Currently the most common indication for an arthrodesis of the knee is a failed infected total knee prosthesis. Other causes of a failed total knee replacement that might necessitate a knee fusion include aseptic loosening, deficient extensor mechanism, poor soft tissues, and Charcot joint. Techniques available for achieving a knee fusion are external fixation and internal fixation methods. The external fixation compression devices have been the most widely used for knee fusion and have been successful until the indications for fusion changed to mostly failed prosthetic knee replacement. With failed total knee replacement, the problem of severe bone loss became an issue, and the external fixation compression devices, even including the biplane external fixators, have been the least successful method reported for gaining fusion. The Ilizarov technique has been shown to achieve rigid fixation despite this bone loss, and a review of reports are showing high fusion rates using this method. Internal fixation methods including plate fixation and intramedullary nails have had the best success in gaining fusion in the face of this bone loss and have replaced external fixation methods as the technique of choice for knee fusion when severe bone loss is present. A review of the literature and a discussion of different fusion techniques are presented including a discussion of the influence that infection has on the success of fusion.

  7. Unsatisfactory Outcome of Arthrodesis Performed After Septic Failure of Revision Total Knee Arthroplasty

    PubMed Central

    Röhner, Eric; Windisch, Christoph; Nuetzmann, Katy; Rau, Max; Arnhold, Michael; Matziolis, Georg

    2015-01-01

    Background: Periprosthetic infection is one of the most dreaded orthopaedic complications. Current treatment procedures include one-stage or two-stage revision total knee arthroplasty. If the periprosthetic infection is no longer controllable after several revision total knee arthroplasties, many surgeons regard knee arthrodesis as a promising option. The aim of our study was to ascertain whether intramedullary nailing results in the suppression or eradication of an infection and to identify risk factors for persistent infection. Methods: All patients who had undergone intramedullary nailing following septic failure of revision total knee arthroplasty between 1997 and 2013 were included in the study. Pathogens, risk factors predisposing to persistent infection, and the rate of persistent infections were recorded. In addition, a visual analog scale (VAS) and Knee injury Osteoarthritis Outcome Score (KOOS), Knee Society Score (KSS), Lysholm, Short Form-36 (SF-36), and Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) questionnaires were completed to assess clinical outcomes and quality of life. Results: Twenty-six patients were included in the study. Thirteen (50%) had a persistent infection requiring additional revision surgery. Nineteen patients (73%) reported persistent pain (VAS score of >3). All scores showed marked impairment of quality of life. Conclusions: Intramedullary nailing following septic failure of revision total knee arthroplasty must be regarded with skepticism, and we cannot recommend it. Repeat revision total knee arthroplasty or amputation should be considered as an alternative in such difficult cases. Level of Evidence: Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence. PMID:25695981

  8. Collateral ligament strains during knee joint laxity evaluation before and after TKA.

    PubMed

    Delport, Hendrik; Labey, Luc; De Corte, Ronny; Innocenti, Bernardo; Vander Sloten, Jos; Bellemans, Johan

    2013-08-01

    Passive knee stability is provided by the soft tissue envelope. There is consensus among orthopedic surgeons that good outcome in Total Knee Arthroplasty requires equal tension in the medial/lateral compartment of the knee joint, as well as equal tension in the flexion/extension gap. The purpose of this study was to quantify the ligament laxity in the normal non-arthritic knee before and after Posterior-Stabilized Total Knee Arthroplasty. We hypothesized that the Medial/Lateral Collateral Ligament shows minimal changes in length when measured directly by extensometers in the native human knee during varus/valgus laxity testing. We also hypothesized that due to differences in material properties and surface geometry, native laxity is difficult to reconstruct using a Posterior-Stabilized Total Knee. Six specimens were used to perform this in vitro cadaver test using extensometers to provide numerical values for laxity and varus-valgus tilting in the frontal plane. This study enabled a precise measurement of varus-valgus laxity as compared with the clinical assessment. The strains in both ligaments in the replaced knee were different from those in the native knee. Both ligaments were stretched in extension, in flexion the Medial Collateral Ligament tends to relax and the Lateral Collateral Ligament remains tight. As material properties and surface geometry of the replaced knee add stiffness to the joint, we recommend to avoid overstuffing the joint, when using this type of Posterior-Stabilized Total Knee Arthroplasty, in order to obtain varus/valgus laxity close to the native joint. Copyright © 2013 Elsevier Ltd. All rights reserved.

  9. Knee extension range of motion and self-report physical function in total knee arthroplasty: mediating effects of knee extensor strength

    PubMed Central

    2013-01-01

    Background Knee extensor strength and knee extension range of motion (ROM) are important predictors of physical function in patients with a total knee arthroplasty (TKA). However, the relationship between the two knee measures remains unclear. The purpose of this study was to examine whether changes in knee extensor strength mediate the association between changes in knee extension ROM and self-report physical function. Methods Data from 441 patients with a TKA were collected preoperatively and 6 months postoperatively. Self-report measure of physical function was assessed by the Short Form 36 (SF-36) questionnaire. Knee extensor strength was measured by handheld dynamometry and knee extension ROM by goniometry. A bootstrapped cross product of coefficients approach was used to evaluate mediation effects. Results Mediation analyses, adjusted for clinicodemographic measures, revealed that the association between changes in knee extension ROM and SF-36 physical function was mediated by changes in knee extensor strength. Conclusions In patients with TKA, knee extensor strength mediated the influence of knee extension ROM on physical function. These results suggest that interventions to improve the range of knee extension may be useful in improving knee extensor performance. PMID:23332039

  10. In vivo determination of total knee arthroplasty kinematics

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Komistek, Richard D; Mahfouz, Mohamed R; Bertin, Kim

    2008-01-01

    The objective of this study was to determine if consistent posterior femoral rollback of an asymmetrical posterior cruciate retaining (PCR) total knee arthroplasty was mostly influenced by the implant design, surgical technique, or presence of a well-functioning posterior cruciate ligament (PCL). Three-dimensional femorotibial kinematics was determined for 80 subjects implanted by 3 surgeons, and each subject was evaluated under fluoroscopic surveillance during a deep knee bend. All subjects in this present study having an intact PCL had a well-functioning PCR knee and experienced normal kinematic patterns, although less in magnitude than the normal knee. In addition, a surprising finding wasmore » that, on average, subjects without a PCL still achieved posterior femoral rollback from full extension to maximum knee flexion. The findings in this study revealed that implant design did contribute to the normal kinematics demonstrated by subjects having this asymmetrical PCR total knee arthroplasty.« less

  11. Anterior knee pain after a total knee arthroplasty: What can cause this pain?

    PubMed Central

    Breugem, Stéfanus Jacob Martinus; Haverkamp, Daniël

    2014-01-01

    Total Knee Arthroplasty has been shown to be a successful procedure for treating patients with osteoarthritis, and yet approximately 5%-10% of patients experience residual pain, especially in the anterior part of the knee. Many theories have been proposed to explain the etiology of this anterior knee pain (AKP) but, despite improvements having been made, AKP remains a problem. AKP can be described as retropatellar or peripatellar pain, which limits patients in their everyday lives. Patients suffering from AKP experience difficulty in standing up from a chair, walking up and down stairs and riding a bicycle. The question asked was: “How can a ‘perfectly’ placed total knee arthroplasty (TKA) still be painful: what can cause this pain?”. To prevent AKP after TKA it is important to first identify the different anatomical structures that can cause this pain. Greater attention to and understanding of AKP should lead to significant pain relief and greater overall patient satisfaction after TKA. This article is a review of what pain is, how nerve signalling works and what is thought to cause Anterior Knee Pain after a Total Knee Arthroplasty. PMID:25035818

  12. Revision total knee arthroplasty in the young patient: is there trouble on the horizon?

    PubMed

    Aggarwal, Vinay K; Goyal, Nitin; Deirmengian, Gregory; Rangavajulla, Ashwin; Parvizi, Javad; Austin, Matthew S

    2014-04-02

    The volume of total knee arthroplasties, including revisions, in young patients is expected to rise. The objective of this study was to compare the reasons for revision and re-revision total knee arthroplasties between younger and older patients, to determine the survivorship of revision total knee arthroplasties, and to identify risk factors associated with failure of revision in patients fifty years of age or younger. Perioperative data were collected for all total knee arthroplasty revisions performed from August 1999 to December 2009. A cohort of eighty-four patients who were fifty years of age or younger and a cohort of eighty-four patients who were sixty to seventy years of age were matched for the date of surgery, sex, and body mass index (BMI). The etiology of failure of the index total knee arthroplasty and all subsequent revision total knee arthroplasties was determined. Kaplan-Meier survival curves were used to evaluate the timing of the primary failure and the survivorship of revision knee procedures. Finally, multivariate Cox regression was used to calculate risk ratios for the influence of age, sex, BMI, and the reason for the initial revision on survival of the revision total knee arthroplasty. The most common reason for the initial revision was aseptic loosening (27%; 95% confidence interval [CI] = 19% to 38%) in the younger cohort and infection (30%; 95% CI = 21% to 40%) in the older cohort. Of the twenty-five second revisions in younger patients, 32% (95% CI = 17% to 52%) were for infection, whereas 50% (95% CI = 32% to 68%) of the twenty-six second revisions in the older cohort were for infection. Cumulative six-year survival rates were 71.0% (95% CI = 60.7% to 83.0%) and 66.1% (95% CI = 54.5% to 80.2%) for revisions in the younger and older cohorts, respectively. Infection and a BMI of ≥ 40 kg/m(2) posed the greatest risk of failure of revision procedures, with risk ratios of 2.731 (p = 0.006) and 2.934 (p = 0.009), respectively. The survivorship of knee revisions in younger patients is a cause of concern, and the higher rates of aseptic failure in these patients may be related to unique demands that they place on the reconstruction. Improvement in implant fixation and treatment of infection when these patients undergo revision total knee arthroplasty is needed.

  13. Total knee arthroplasty in a rheumatoid arthritic knee with large geode: a case report.

    PubMed

    Shih, H N; Hsu, K Y; Tan, C F; Hsueh, S; Hsu, R W

    1997-09-01

    Geodes (subchondral cysts) are a well-known manifestation of rheumatoid arthritis. Solitary cysts or cysts larger than 2 cm are not generally found in the knee joint of patients with rheumatoid arthritis (RA). We report a case of RA involving both knees with a giant geode over the right proximal tibia. Surgical treatment was performed including synovectomy, cyst enucleation and packing of autogenous bone chips followed by primary total knee arthroplasty. The postsurgical result was excellent with the knee restored to good function and complete healing of the cystic lesion.

  14. Clinical Outcomes in Men and Women following Total Knee Arthroplasty with a High-Flex Knee: No Clinical Effect of Gender.

    PubMed

    Nassif, Jeffrey M; Pietrzak, William S

    2015-01-01

    While it is generally recognized that anatomical differences exist between the male and female knee, the literature generally refutes the clinical need for gender-specific total knee prostheses. It has been found that standard, unisex knees perform as well, or better, in women than men. Recently, high-flex knees have become available that mechanically accommodate increased flexion yet no studies have directly compared the outcomes of these devices in men and women to see if gender-based differences exist. We retrospectively compared the performance of the high-flex Vanguard knee (Biomet, Warsaw, IN) in 716 male and 1,069 female knees. Kaplan-Meier survivorship was 98.5% at 5.6-5.7 years for both genders. After 2 years, mean improvements in Knee Society Knee and Function scores for men and women (50.9 versus 46.3; 26.5 versus 23.1) and corresponding SF-12 Mental and Physical scores (0.2 versus 2.2; 13.7 versus 12.2) were similar with differences not clinically relevant. Postoperative motion gains as a function of preoperative motion level were virtually identical in men and women. This further confirms the suitability of unisex total knee prostheses for both men and women.

  15. The Effect on Long-Term Survivorship of Surgeon Preference for Posterior-Stabilized or Minimally Stabilized Total Knee Replacement: An Analysis of 63,416 Prostheses from the Australian Orthopaedic Association National Joint Replacement Registry.

    PubMed

    Vertullo, Christopher J; Lewis, Peter L; Lorimer, Michelle; Graves, Stephen E

    2017-07-05

    Controversy still exists as to the optimum management of the posterior cruciate ligament (PCL) in total knee arthroplasty. Surgeons can choose to kinematically substitute the PCL with a posterior-stabilized total knee replacement or alternatively to utilize a cruciate-retaining, also known as minimally stabilized, total knee replacement. Proponents of posterior-stabilized total knee replacement propose that the reported lower survivorship in registries when directly compared with minimally stabilized total knee replacement is due to confounders such as selection bias because of the preferential usage of posterior-stabilized total knee replacement in more complex or severe cases. In this study, we aimed to eliminate these possible confounders by performing an instrumental variable analysis based on surgeon preference to choose either posterior-stabilized or minimally stabilized total knee replacement, rather than the actual prosthesis received. Cumulative percent revision, hazard ratio (HR), and revision diagnosis data were obtained from the Australian Orthopaedic Association National Joint Replacement Registry from September 1, 1999, to December 31, 2014, for 2 cohorts of patients, those treated by high-volume surgeons who preferred minimally stabilized replacements and those treated by high-volume surgeons who preferred posterior-stabilized replacements. All patients had a diagnosis of osteoarthritis and underwent fixed-bearing total knee replacement with patellar resurfacing. At 13 years, the cumulative percent revision was 5.0% (95% confidence interval [CI], 4.0% to 6.2%) for the surgeons who preferred the minimally stabilized replacements compared with 6.0% (95% CI, 4.2% to 8.5%) for the surgeons who preferred the posterior-stabilized replacements. The revision risk for the surgeons who preferred posterior-stabilized replacements was significantly higher for all causes (HR = 1.45 [95% CI, 1.30 to 1.63]; p < 0.001), for loosening or lysis (HR = 1.93 [95% CI, 1.58 to 2.37]; p < 0.001), and for infection (HR = 1.51 [95% CI, 1.25 to 1.82]; p < 0.001). This finding was irrespective of patient age and was evident with cemented fixation and with both cross-linked polyethylene and non-cross-linked polyethylene. However, the higher revision risk was only evident in male patients. There was a 45% higher risk of revision for the patients of surgeons who preferred a posterior-stabilized total knee replacement compared with the patients of surgeons who preferred a minimally stabilized total knee replacement. Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence.

  16. The Effect of Electrocautery around the Patellar Rim in Patellar Non-Resurfacing Total Knee Arthroplasty

    PubMed Central

    Yim, Soo Jae; Jang, Mun Suk; Kim, Wook Joong; Kang, Hee Kyung

    2012-01-01

    Purpose The purpose of this study was to evaluate the clinical effect of electrocautery on the reduction of pain in patellar non-resurfacing bilateral total knee arthroplasty. Materials and Methods A total of 50 patients were enrolled into this study; all patients had undergone bilateral patellar non-resurfacing total knee arthoplasty at our hospital, between January 2007 to December 2008. The minimum follow-up period was 1 year. The electrocautery of the patellar rim was performed randomly on one side only. The clinical results were evaluated between the electrocautery group and the non-electrocautery group based on measures of anterior knee pain, range of motion, American Knee Society clinical rating score, Feller knee score, Western Ontario and McMaster Universities score, and radiographic analysis. Results There were statistically significant differences between preoperative and postoperative status for all parameters. There were no statistically significant differences noted between the electrocautery group and the non electrocautery group for all parameters. Conclusions Electrocautery of patellar rim is thought to be less effective in reducing anterior knee pain. PMID:22708111

  17. Knee arthrodesis with an intramedullary nail: a retrospective study.

    PubMed

    De Vil, Jeroen; Almqvist, Karl Fredrik; Vanheeren, Philippe; Boone, Barbara; Verdonk, René

    2008-07-01

    A group of 19 patients who underwent knee arthrodesis with use of an intramedullary nail between 1996 and 2005, was studied. In the majority of patients knee arthrodesis was performed as a salvage procedure for the limb following an infected total knee arthroplasty. The outcome of the procedure was evaluated with radiographs, the SF-36 score and the Oxford 12-item knee score. The functional result of a successful arthrodesis was found to be comparable with that of a revised hinged total knee arthroplasty. Knee arthrodesis with an intramedullary nail allows weightbearing within 1 week and is accompanied by a high rate of pain relief. However, recurrence of infection is the most challenging problem.

  18. Correlation of a single assessment numeric evaluation (SANE) rating with modified Cincinnati knee rating system and IKDC subjective total scores for patients after ACL reconstruction or knee arthroscopy.

    PubMed

    Shelbourne, K Donald; Barnes, Adam F; Gray, Tinker

    2012-11-01

    Limited studies exist regarding how well a single assessment numeric evaluation (SANE) rating correlates with validated knee surveys. To determine whether a SANE rating correlates positively with the International Knee Documentation Committee (IKDC) and the modified Cincinnati Knee Rating System (CKRS) total scores after knee surgery. Cohort study (Diagnosis); Level of evidence, 2. Patients undergoing either anterior cruciate ligament (ACL) reconstruction or knee arthroscopy were prospectively given subjective evaluations yearly after surgery between January 2000 and June 2011. Subjective evaluations were obtained using modified CKRS and IKDC subjective knee surveys and a SANE rating. Interclass correlation coefficient was used to determine the correlation of the SANE rating to the survey total scores. Bland-Altman method was used to access precision and limits of agreement between scores. In addition, the data were analyzed according to sex and age categories (<18, 18-24, 25-40, >40 years). A total of 11,939 surveys were collected from 3209 patients (mean, 3.7 surveys/person; range, 1-22) after ACL reconstruction with a mean survey age of 35.2 ± 11.9 years (range, 13-72). A total of 4615 surveys were collected from 1813 patients (mean, 2.6 surveys/person; range, 1-17) after knee arthroscopy with a mean survey age of 47.4 ± 14.6 years (range, 11-88). For patients who underwent ACL reconstruction, the SANE rating had a moderate positive correlation of 0.66 to the total survey scores. For patients who underwent knee arthroscopies, the SANE rating had a strong positive correlation of 0.74 to total scores. There was minimal difference in correlations based on age group or sex. Bland-Altman analysis showed that the limits of agreement between the SANE score and the 2 surveys were met for at least 94% of patients in both patient groups. The SANE ratings exhibited moderate to strong positive correlations with the modified CKRS and IKDC subjective surveys after ACL reconstruction and knee arthroscopy for patients of all ages and both sexes.

  19. A randomised, controlled trial of circumpatellar electrocautery in total knee replacement without patellar resurfacing.

    PubMed

    van Jonbergen, H P W; Scholtes, V A B; van Kampen, A; Poolman, R W

    2011-08-01

    The efficacy of circumpatellar electrocautery in reducing the incidence of post-operative anterior knee pain is unknown. We conducted a single-centre, outcome-assessor and patient-blinded, parallel-group, randomised, controlled trial to compare circumpatellar electrocautery with no electrocautery in total knee replacement in the absence of patellar resurfacing. Patients requiring knee replacement for primary osteoarthritis were randomly assigned circumpatellar electrocautery (intervention group) or no electrocautery (control group). The primary outcome measure was the incidence of anterior knee pain. A secondary measure was the standardised clinical and patient-reported outcomes determined by the American Knee Society scores and the Western Ontario and McMaster Universities (WOMAC) osteoarthritis index. A total of 131 knees received circumpatellar electrocautery and 131 had no electrocautery. The overall incidence of anterior knee pain at follow-up at one year was 26% (20% to 31%), with 19% (12% to 26%) in the intervention group and 32% (24% to 40%) in the control group (p = 0.02). The relative risk reduction from electrocautery was 40% (9% to 61%) and the number needed to treat was 7.7 (4.3 to 41.4). The intervention group had a better mean total WOMAC score at follow-up at one year compared with the control group (16.3 (0 to 77.7) versus 21.6 (0 to 76.7), p = 0.04). The mean post-operative American Knee Society knee scores and function scores were similar in the intervention and control groups (knee score: 92.4 (55 to 100) versus 90.4 (51 to 100), respectively (p = 0.14); function score: 86.5 (15 to 100) versus 84.5 (30 to 100), respectively (p = 0.49)). Our study suggests that in the absence of patellar resurfacing electrocautery around the margin of the patella improves the outcome of total knee replacement.

  20. Vibration arthrometry in the patients with failed total knee replacement.

    PubMed

    Jiang, C C; Lee, J H; Yuan, T T

    2000-02-01

    This is a preliminary research on the vibration arthrometry of artificial knee joint in vivo. Analyzing the vibration signals measured from the accelerometer on patella, there are two speed protocols in knee kinematics: 1) 2 degrees/s, the signal is called "physiological patellofemoral crepitus (PPC)", and 2) 67 degrees/s, the signal is called "vibration signal in rapid knee motion". The study has collected 14 patients who had revision total knee arthroplasty due to prosthetic wear or malalignment represent the failed total knee replacement (FTKR), and 12 patients who had just undergone the primary total knee arthroplasty in the past two to six months and have currently no knee pain represent the normal total knee replacement (NTKR). FTKR is clinically divided into three categories: metal wear, polyethylene wear of the patellar component, and no wear but with prosthesis malalignment. In PPC, the value of root mean square (rms) is used as a parameter; in vibration signals in rapid knee motion, autoregressive modeling is used for adaptive segmentation and extracting the dominant pole of each signal segment to calculate the spectral power ratios in f < 100 Hz and f > 500 Hz. It was found that in the case of metal wear, the rms value of PPC signal is far greater than a knee joint with polyethylene wear and without wear, i.e., PPC signal appears only in metal wear. As for vibration signals in rapid knee motion, prominent time-domain vibration signals could be found in the FTKR patients with either polyethylene or metal wear of the patellar component. We also found that for normal knee joint, the spectral power ratio of dominant poles has nearly 80% distribution in f < 100 Hz, is between 50% and 70% for knee with polyethylene wear and below 30% for metal wear, whereas in f > 500 Hz, spectral power ratio of dominant poles has over 30% distribution in metal wear but only nonsignificant distribution in polyethylene wear, no wear, and normal knee. The results show that vibration signals in rapid knee motion can be used for effectively detecting polyethylene wear of the patellar component in the early stage, while PPC signals can only be used to detect prosthetic metal wear in the late stage.

  1. Risk of total knee arthroplasty after operatively treated tibial plateau fracture: a matched-population-based cohort study.

    PubMed

    Wasserstein, David; Henry, Patrick; Paterson, J Michael; Kreder, Hans J; Jenkinson, Richard

    2014-01-15

    The aims of operative treatment of displaced tibial plateau fractures are to stabilize the injured knee to restore optimal function and to minimize the risk of posttraumatic arthritis and the eventual need for total knee arthroplasty. The purpose of our study was to define the rate of subsequent total knee arthroplasty after tibial plateau fractures in a large cohort and to compare that rate with the rate in the general population. All patients sixteen years of age or older who had undergone surgical treatment of a tibial plateau fracture from 1996 to 2009 in the province of Ontario, Canada, were identified from administrative health databases with use of surgeon fee codes. Each member of the tibial plateau fracture cohort was matched to four individuals from the general population according to age, sex, income, and urban/rural residence. The rates of total knee arthroplasty at two, five, and ten years were compared by using time-to-event analysis. A separate Cox proportional hazards model was used to explore the influence of patient, provider, and surgical factors on the time to total knee arthroplasty. We identified 8426 patients (48.5% female; median age, 48.9 years) who had undergone fixation of a tibial plateau fracture and matched them to 33,698 controls. The two, five, and ten-year rates of total knee arthroplasty in the plateau fracture and control cohorts were 0.32% versus 0.29%, 5.3% versus 0.82%, and 7.3% versus 1.8%, respectively (p < 0.0001). After adjustment for comorbidity, plateau fracture surgery was found to significantly increase the likelihood of total knee arthroplasty (hazard ratio [HR], 5.29 [95% confidence interval, 4.58, 6.11]; p < 0.0001). Higher rates of total knee arthroplasty were also associated with increasing age (HR, 1.03 [1.03, 1.04] per year over the age of forty-eight; p < 0.0001), bicondylar fracture (HR, 1.53 [1.26, 1.84]; p < 0.0001), and greater comorbidity (HR, 2.17 [1.70, 2.77]; p < 0.001). Ten years after tibial plateau fracture surgery, 7.3% of the patients had had a total knee arthroplasty. This corresponds to a 5.3 times increase in likelihood compared with a matched group from the general population. Older patients and those with more severe fractures are also more likely to need total knee arthroplasty after repair of a tibial plateau fracture.

  2. Leg stiffness, valgus knee motion, and Q-angle are associated with hypertrophic soft patella tendon and idiopathic knee pain in adolescent basketball players.

    PubMed

    Satkunskiene, Danguole; Mickevicius, Mantas; Snieckus, Audrius; Kamandulis, Sigitas

    2017-01-01

    Knee pain without knee degenerative symptoms is a common phenomenon among young basketball players. The aim of this study was to identify factors predisposing young basketball players to suffer from knee pain. The study involved 20 male adolescent (14-15 years) basketball players who were divided into two equal groups based on knee pain symptoms. Legs torque was tested on an isokinetic dynamometer. The length, elongation and the cross-sectional area (CSA) of the patellar tendon were measured with ultrasonography. Quadriceps angle (Q-angle), knee valgus motion, and joint angular displacement in the sagittal plane were analyzed using video recording during countermovement jump. Ground reaction force was measured using a force platform. Knee pain (KP) participants had a significantly lower Q-angle (P=0.045) and lower maximum varus knee angle (P=0.035), and a greater knee inside displacement (P=0.039) during squat phase. In the KP group, the CSA at the top of the tendon was significantly greater than in the middle (P=0.006) and at the bottom (P=0.039). Absolute tendon stiffness (P=0.013) and Young's modulus (P=0.034) were significantly lower in the KP group compared with controls. Leg stiffness during landing was significantly greater in the control group (P=0.015). Leg stiffness, valgus knee motion, and Q-angle are associated with hypertrophic soft patella tendon and idiopathic knee pain in adolescent basketball players.

  3. Effect of rotational alignment on outcome of total knee arthroplasty

    PubMed Central

    Breugem, Stefan J; van den Bekerom, Michel PJ; Tuinebreijer, Willem E; van Geenen, Rutger C I

    2015-01-01

    Background and purpose Poor outcomes have been linked to errors in rotational alignment of total knee arthroplasty components. The aims of this study were to determine the correlation between rotational alignment and outcome, to review the success of revision for malrotated total knee arthroplasty, and to determine whether evidence-based guidelines for malrotated total knee arthroplasty can be proposed. Patients and methods We conducted a systematic review including all studies reporting on both rotational alignment and functional outcome. Comparable studies were used in a correlation analysis and results of revision were analyzed separately. Results 846 studies were identified, 25 of which met the inclusion criteria. From this selection, 11 studies could be included in the correlation analysis. A medium positive correlation (ρ = 0.44, 95% CI: 0.27–0.59) and a large positive correlation (ρ = 0.68, 95% CI: 0.64–0.73) were found between external rotation of the tibial component and the femoral component, respectively, and the Knee Society score. Revision for malrotation gave positive results in all 6 studies in this field. Interpretation Medium and large positive correlations were found between tibial and femoral component rotational alignment on the one hand and better functional outcome on the other. Revision of malrotated total knee arthroplasty may be successful. However, a clear cutoff point for revision for malrotated total knee arthroplasty components could not be identified. PMID:25708694

  4. The Time Course of Knee Swelling Post Total Knee Arthroplasty and Its Associations with Quadriceps Strength and Gait Speed.

    PubMed

    Pua, Yong-Hao

    2015-07-01

    This study examines the time course of knee swelling post total knee arthroplasty (TKA) and its associations with quadriceps strength and gait speed. Eighty-five patients with unilateral TKA participated. Preoperatively and on post-operative days (PODs) 1, 4, 14, and 90, knee swelling was measured using bioimpedance spectrometry. Preoperatively and on PODs 14 and 90, quadriceps strength was measured using isokinetic dynamometry while fast gait speed was measured using the timed 10-meter walk. On POD1, knee swelling increased ~35% from preoperative levels after which, knee swelling reduced but remained at ~11% above preoperative levels on POD90. In longitudinal, multivariable analyses, knee swelling was associated with quadriceps weakness (P<0.01) and slower gait speed (P=0.03). Interventions to reduce post-TKA knee swelling may be indicated to improve quadriceps strength and gait speed. Copyright © 2015 Elsevier Inc. All rights reserved.

  5. Poor WOMAC scores in contralateral knee negatively impact TKA outcomes: data from the osteoarthritis initiative.

    PubMed

    Kahn, Timothy L; Soheili, Aydin C; Schwarzkopf, Ran

    2014-08-01

    While total knee arthroplasty (TKA) has been shown to have excellent outcomes, a significant proportion of patients experience relatively poor post-operative function. In this study, we test the hypothesis that the level of osteoarthritic symptoms in the contralateral knee at the time of TKA is associated with poorer post-operative outcomes in the operated knee. Using longitudinal cohort data from the Osteoarthritis Initiative (OAI), we included 171 patients who received a unilateral TKA. We compared pre-operative Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) scores in the contralateral knee to post-operative WOMAC scores in the index knee. Pre-operative contralateral knee WOMAC scores were associated with post-operative index knee WOMAC Total scores, indicating that the health of the pre-operative contralateral knee is a significant factor in TKA outcomes. Copyright © 2014 Elsevier Inc. All rights reserved.

  6. Spontaneous patella fracture associated with anterior tibial tubercle pseudarthrosis in a revised knee replacement following knee Arthrodesis

    PubMed Central

    2013-01-01

    Background Conversion of a knee arthrodesis to a Total Knee Arthroplasty is an uncommon procedure. Revision Total Knee Arthroplasty in this setting presents the surgeon with a number of challenges including the management of the extensor mechanism and patella. Case presentation We describe a unique case of a 69 years old Caucasian man who underwent a revision Total Knee Arthroplasty using a tibial tubercle osteotomy after a previous conversion of a knee arthrodesis without patella resurfacing. Unfortunately 9 months following surgery a tibial tubercle pseudarthrosis and spontaneous patella fracture occurred. Both were managed with open reduction and internal fixation. At 30 months follow-up the tibial tubercle osteotomy had completely consolidated while the patella fracture was still evident but with no signs of further displacement. The patient was completely satisfied with the outcome and had a painless range of knee flexion between 0-95°. Conclusions We believe that patients undergoing this type of surgery require careful counseling regarding the risk of complications both during and after surgery despite strong evidence supporting improved functional outcomes. PMID:24195600

  7. TOTAL KNEE REPLACEMENT IN PATIENTS WITH BELOW-KNEE AMPUTATION

    PubMed Central

    Karam, Matthew D; Willey, Michael; Shurr, Donald G

    2010-01-01

    Total knee replacement (TKR) is reserved for patients with severe and disabling arthritis that is non-responsive to conservative measures. Based on existing data, total knee replacement is a safe and cost-effective treatment for alleviating pain and improving physical function in patients who do not respond to conservative therapy. Despite the large variation in health status of patients and types of prosthesis implanted, total knee replacement has proven to be a relatively low risk and successful operation. Each year in the United States surgeons perform approximately 300,000 TKR.1 Likewise, lower extremity amputation is commonly performed in the United States with an annual incidence of 110,000 per year.2 Nearly 70% of all lower extremity amputations are performed as the result of chronic vascular disease, followed by trauma (22%), congenital etiology and tumor (4% each).3 Approximately 50% of all lower extremity amputations are performed secondary to complications from Diabetes Mellitus. Norvell et al. demonstrated that patients who have previously undergone transtibial amputation and ambulate with a prosthesis are more likely to develop degenerative joint disease in the con-tralateral extremity than the ipsilateral extremity.4 Further, radiographic changes consistent with osteoporosis have been demonstrated in up to 88% of limbs that have undergone transtibial amputation.8 To our knowledge, there have been only three reported cases of total knee replacement in patients with ipsilateral transtibial amputation.5,7 The purpose of the present study is to review the existing data on total knee replacement in patients who have undergone transtibial amputation. Further we present a patient with a transtibial amputation who underwent contralateral total knee replacement. PMID:21045987

  8. Effect of Body Mass Index on Reoperation and Complications After Total Knee Arthroplasty.

    PubMed

    Wagner, Eric R; Kamath, Atul F; Fruth, Kristin; Harmsen, William S; Berry, Daniel J

    2016-12-21

    High body mass index (BMI) is associated with increased rates of complications after total knee arthroplasty. To date, to our knowledge, studies have examined risk as a dichotomous variable using specific BMI thresholds. The purpose of this investigation was to quantify implant survival and the risk of common complications after total knee arthroplasty using BMI as a continuous variable. Using prospectively collected data from our institutional total joint registry, we analyzed 22,289 consecutive knees, in 16,136 patients, treated with primary total knee arthroplasty from 1985 to 2012. The mean BMI of these patients at the time of the surgical procedure was 31.3 kg/m (range, 11 to 69 kg/m). The Kaplan-Meier survival method was used to estimate survivorship, reoperations, and common complications, with associations of outcomes assessed using a Cox regression model. Utilizing smoothing spline parameterization, we found that reoperation (p < 0.001) and implant revision or removal rates (p < 0.001) increased with increasing BMI after total knee arthroplasty. Increasing BMI also was associated with increased rates of wound infection (hazard ratio [HR], 1.07; p < 0.001) and deep infection (HR, 1.08; p < 0.001) per unit of BMI over 35 kg/m. A BMI of 35 to 40 kg/m was associated with a higher rate of implant revision for aseptic loosening (p < 0.001) and for polyethylene wear (p < 0.001) compared with a BMI of 18 to 24.99 kg/m. There was no correlation between BMI and risk of venous thromboembolism, tibiofemoral instability, or need for knee manipulation. The rates of reoperation, implant revision or removal, and many common complications after total knee arthroplasty were strongly associated with BMI. Prognostic Level IV. See Instructions for Authors for a complete description of levels of evidence.

  9. Interventions for the prediction and management of chronic postsurgical pain after total knee replacement: systematic review of randomised controlled trials

    PubMed Central

    Beswick, Andrew D; Wylde, Vikki; Gooberman-Hill, Rachael

    2015-01-01

    Objectives Total knee replacement can be a successful operation for pain relief. However, 10–34% of patients experience chronic postsurgical pain. Our aim was to synthesise evidence on the effectiveness of applying predictive models to guide preventive treatment, and for interventions in the management of chronic pain after total knee replacement. Setting We conducted a systematic review of randomised controlled trials using appropriate search strategies in the Cochrane Library, MEDLINE and EMBASE from inception to October 2014. No language restrictions were applied. Participants Adult patients receiving total knee replacement. Interventions Predictive models to guide treatment for prevention of chronic pain. Interventions for management of chronic pain. Primary and secondary outcome measures Reporting of specific outcomes was not an eligibility criterion but we sought outcomes relating to pain severity. Results No studies evaluated the effectiveness of predictive models in guiding treatment and improving outcomes after total knee replacement. One study evaluated an intervention for the management of chronic pain. The trial evaluated the use of a botulinum toxin A injection with antinociceptive and anticholinergic activity in 49 patients with chronic postsurgical pain after knee replacement. A single injection provided meaningful pain relief for about 40 days and the authors acknowledged the need for a large trial with repeated injections. No trials of multidisciplinary interventions or individualised treatments were identified. Conclusions Our systematic review highlights a lack of evidence about the effectiveness of prediction and management strategies for chronic postsurgical pain after total knee replacement. As a large number of people are affected by chronic pain after total knee replacement, development of an evidence base about care for these patients should be a research priority. PMID:25967998

  10. RSA and registries: the quest for phased introduction of new implants.

    PubMed

    Nelissen, Rob G H H; Pijls, Bart G; Kärrholm, Johan; Malchau, Henrik; Nieuwenhuijse, Marc J; Valstar, Edward R

    2011-12-21

    Although the overall survival of knee and hip prostheses at ten years averages 90%, recent problems with several hip and knee prostheses have illustrated that the orthopaedic community, industry, and regulators can still further improve patient safety. Given the early predictive properties of roentgen stereophotogrammetric analysis (RSA) and the meticulous follow-up of national joint registries, these two methods are ideal tools for such a phased clinical introduction. In this paper, we elaborate on the predictive power of RSA within a two-year follow-up after arthroplasty and its relationship to national joint registries. The association between RSA prosthesis-migration data and registry data is evaluated. The five-year rate of revision of RSA-tested total knee replacements was compared with that of non-RSA-tested total knee replacements. Data were extracted from the published results of the national joint registries of Sweden, Australia, and New Zealand. There was a 22% to 35% reduction in the number of revisions of RSA-tested total knee replacements as compared with non-RSA-tested total knee replacements in the national joint registries. Assuming that the total cost of total knee arthroplasty is $37,000 in the United States, a 22% to 35% reduction in the number of revisions (currently close to 55,000 annually) could lead to an estimated annual savings of over $400 million to the health-care system. The phased clinical introduction of new prostheses with two-year RSA results as a qualitative tool could lead to better patient care and could reduce the costs associated with revision total knee arthroplasty. Follow-up in registries is necessary to substantiate these results and to improve post-market surveillance.

  11. The effect of the training with the different combinations of frequency and peak-to-peak vibration displacement of whole-body vibration on the strength of knee flexors and extensors

    PubMed Central

    Król, P; Sobota, G; Polak, A; Bacik, B; Juras, G

    2017-01-01

    Whole-body vibration training has become a popular method used in sports and physiotherapy. The study aimed to evaluate the effect of different vibration frequency and peak-to-peak displacement combinations on men knee flexors and extensors strength in isokinetic conditions. The sample consisted of 49 male subjects randomly allocated to seven comparative groups, six of which exercised on a vibration platform with parameters set individually for the groups. The experimental groups were exposed to vibrations 3 times a week for 4 weeks. The pre- and post- isokinetic strength tests, with the angular velocities of 240°/s and 30°/s, were recorded prior to and 2 days after the training. After 4 weeks of whole-body vibration training, a significant increase was noted regarding the mean values of peak torque, average peak torque and total work for knee flexors at high angular velocity in Groups I (60 Hz/4 mm) and V (40 Hz/2 mm) (p<0.05). The mean percentage values of post-training changes to study parameters suggest that the training had the most beneficial effect in Groups I (60 Hz/4 mm) and IV (60 Hz/2 mm) (p<0.05). Whole-body vibrations during static exercise beneficially affected knee flexor strength profile in young men at high angular velocity. The combinations of 60 Hz/4 mm seem to have the most advantageous effects on muscle strength parameters. PMID:28566806

  12. Serum adipokines, adipose tissue measurements and metabolic parameters in patients with advanced radiographic knee osteoarthritis.

    PubMed

    Toussirot, Eric; Michel, Fabrice; Béreau, Matthieu; Dehecq, Barbara; Gaugler, Béatrice; Wendling, Daniel; Grandclément, Emilie; Saas, Philippe; Dumoulin, Gilles

    2017-11-01

    We conducted the present study to evaluate the serum levels of adipokines (leptin, total and high molecular adiponectin, resistin), a marker of cartilage breakdown (C2C), and ghrelin together with body composition in patients with knee osteoarthritis (OA). Fifty patients and 50 sex-matched healthy subjects (HS) were evaluated. Knee OA was scored according to the Kellgren-Lawrence (KL) grade. Body composition parameters including lean mass and measurements of fat mass (total fat, adiposity, fat in the android and gynoid regions, visceral fat and trunk/legs fat ratio) were obtained using dual energy X-ray absorptiometry. Most of the recruited patients (88%) had advanced knee OA with KL grade 3 or 4. The patients had higher body mass index than HS (p < 0.0001). Serum leptin, high molecular adiponectin, resistin and ghrelin levels did not differ between patients and HS. Total adiponectin was higher in women with OA compared to women from the HS group (p = 0.004). Total fat mass, adiposity and measurements of central adiposity (fat in the android region, trunk/lower limbs fat ratio and visceral fat) were increased in patients with knee OA (all p < 0.05). Total adiponectin was borderline associated with the severity of OA. Our results show that total adiponectin is significantly increased in women with advanced knee OA. Independently of gender, patients with severe knee OA were characterized by a significant excess of fat with a distribution toward the visceral region. This abnormal body composition may contribute to the cardiometabolic profile that is described in patients with knee OA.

  13. Impact of total knee replacement practice: cost effectiveness analysis of data from the Osteoarthritis Initiative.

    PubMed

    Ferket, Bart S; Feldman, Zachary; Zhou, Jing; Oei, Edwin H; Bierma-Zeinstra, Sita M A; Mazumdar, Madhu

    2017-03-28

    Objectives  To evaluate the impact of total knee replacement on quality of life in people with knee osteoarthritis and to estimate associated differences in lifetime costs and quality adjusted life years (QALYs) according to use by level of symptoms. Design  Marginal structural modeling and cost effectiveness analysis based on lifetime predictions for total knee replacement and death from population based cohort data. Setting  Data from two studies-Osteoarthritis Initiative (OAI) and the Multicenter Osteoarthritis Study (MOST)-within the US health system. Participants  4498 participants with or at high risk for knee osteoarthritis aged 45-79 from the OAI with no previous knee replacement (confirmed by baseline radiography) followed up for nine years. Validation cohort comprised 2907 patients from MOST with two year follow-up. Intervention  Scenarios ranging from current practice, defined as total knee replacement practice as performed in the OAI (with procedural rates estimated by a prediction model), to practice limited to patients with severe symptoms to no surgery. Main outcome measures  Generic (SF-12) and osteoarthritis specific quality of life measured over 96 months, model based QALYs, costs, and incremental cost effectiveness ratios over a lifetime horizon. Results  In the OAI, total knee replacement showed improvements in quality of life with small absolute changes when averaged across levels of confounding variables: 1.70 (95% uncertainty interval 0.26 to 3.57) for SF-12 physical component summary (PCS); -10.69 (-13.39 to -8.01) for Western Ontario and McMaster Universities arthritis index (WOMAC); and 9.16 (6.35 to 12.49) for knee injury and osteoarthritis outcome score (KOOS) quality of life subscale. These improvements became larger with decreasing functional status at baseline. Provision of total knee replacement to patients with SF-12 PCS scores <35 was the optimal scenario given a cost effectiveness threshold of $200 000/QALY, with cost savings of $6974 ($5789 to $8269) and a minimal loss of 0.008 (-0.056 to 0.043) QALYs compared with current practice. These findings were reproduced among patients with knee osteoarthritis from the MOST cohort and were robust against various scenarios including increased rates of total knee replacement and mortality and inclusion of non-healthcare costs but were sensitive to increased deterioration in quality of life without surgery. In a threshold analysis, total knee replacement would become cost effective in patients with SF-12 PCS scores ≤40 if the associated hospital admission costs fell below $14 000 given a cost effectiveness threshold of $200 000/QALY. Conclusion  Current practice of total knee replacement as performed in a recent US cohort of patients with knee osteoarthritis had minimal effects on quality of life and QALYs at the group level. If the procedure were restricted to more severely affected patients, its effectiveness would rise, with practice becoming economically more attractive than its current use. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  14. Intramedullary knee arthrodesis as a salvage procedure after failed total knee replacement.

    PubMed

    Panagiotopoulos, E; Kouzelis, A; Matzaroglou, Ch; Saridis, A; Lambiris, E

    2006-12-01

    Septic and aseptic loosening with or without extensive bone loss after total knee replacement are the most common indications for knee fusion. Both external fixation and intramedullary nailing can be used for the treatment, though the latter appears to be the method of choice for most patients. Nine patients were treated after a total knee replacement failure using intramedullary nailing. A long intramedullary nail with a proximal interlocking screw was used in five cases, and a customised nail was used in four cases. Successful fusion occurred in eight of nine patients (89%). Average time for the joint union was 6.5 months, and average operative blood loss was 860 ml. In two patients, iliac crest and patellar bone graft were also used. In conclusion, intramedullary nailing can give excellent results in achieving knee fusion after a failed knee replacement as it allows early weight bearing and at the same time offers stability, pain relief, and a high rate of union, even though the surgical technique is demanding.

  15. Mobile bearing vs fixed bearing prostheses for posterior cruciate retaining total knee arthroplasty for postoperative functional status in patients with osteoarthritis and rheumatoid arthritis.

    PubMed

    Hofstede, Stefanie N; Nouta, Klaas Auke; Jacobs, Wilco; van Hooff, Miranda L; Wymenga, Ate B; Pijls, Bart G; Nelissen, Rob G H H; Marang-van de Mheen, Perla J

    2015-02-04

    It is unclear whether there are differences in benefits and harms between mobile and fixed prostheses for total knee arthroplasty (TKA). The previous Cochrane review published in 2004 included two articles. Many more trials have been performed since then; therefore an update is needed. To assess the benefits and harms of mobile bearing compared with fixed bearing cruciate retaining total knee arthroplasty for functional and clinical outcomes in patients with osteoarthritis (OA) or rheumatoid arthritis (RA). We searched The Cochrane Library, PubMed, EMBASE, CINAHL and Web of Science up to 27 February 2014, and the trial registers ClinicalTrials.gov, Multiregister, Current Controlled Trials and the World Health Organization (WHO) International Clinical Trials Registry Platform for data from unpublished trials, up to 11 February 2014. We also screened the reference lists of selected articles. We selected randomised controlled trials comparing mobile bearing with fixed bearing prostheses in cruciate retaining TKA among patients with osteoarthritis or rheumatoid arthritis, using functional or clinical outcome measures and follow-up of at least six months. We used standard methodological procedures as expected by The Cochrane Collaboration. We found 19 studies with 1641 participants (1616 with OA (98.5%) and 25 with RA (1.5%)) and 2247 knees. Seventeen new studies were included in this update.Quality of the evidence ranged from moderate (knee pain) to low (other outcomes). Most studies had unclear risk of bias for allocation concealment, blinding of participants and personnel, blinding of outcome assessment and selective reporting, and high risk of bias for incomplete outcome data and other bias. Knee painWe calculated the standardised mean difference (SMD) for pain, using the Knee Society Score (KSS) and visual analogue scale (VAS) in 11 studies (58%) and 1531 knees (68%). No statistically significant differences between groups were reported (SMD 0.09, 95% confidence interval (CI) -0.03 to 0.22, P value 0.15). This represents an absolute risk difference of 2.4% points higher (95% CI 0.8% lower to 5.9% higher) on the KSS pain scale and a relative percent change of 0.22% (95% CI 0.07% lower to 0.53% higher). The results were homogeneous. Clinical and functional scores The KSS clinical score did not differ statistically significantly between groups (14 studies (74%) and 1845 knees (82%)) with a mean difference (MD) of -1.06 points (95% CI -2.87 to 0.74, P value 0.25) and heterogeneous results. KSS function was reported in 14 studies (74%) with 1845 knees (82%) as an MD of -0.10 point (95% CI -1.93 to 1.73, P value 0.91) and homogeneous results. In two studies (11%), the KSS total score was favourable for mobile bearing (159 vs 132 for fixed bearing), with MD of -26.52 points (95% CI -45.03 to -8.01, P value 0.005), but with a wide 95% confidence interval indicating uncertainty about the estimate.Other reported scoring systems did not show statistically significant differences: Hospital for Special Surgery (HSS) score (seven studies (37%) in 1021 knees (45%)) with an MD of -1.36 (95% CI -4.18 to 1.46, P value 0.35); Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) total score (two studies (11%), 167 knees (7%)) with an MD of -4.46 (95% CI -16.26 to 7.34, P value 0.46); and Oxford total (five studies (26%), 647 knees (29%) with an MD of -0.25 (95% CI -1.41 to 0.91, P value 0.67). Health-related quality of lifeThree studies (16%) with 498 knees (22%) reported on health-related quality of life, and no statistically significant differences were noted between the mobile bearing and fixed bearing groups. The Short Form (SF)-12 Physical Component Summary had an MD of -1.96 (95% CI -4.55 to 0.63, P value 0.14) and heterogeneous results. Revision surgeryTwenty seven revisions (1.3%) were performed in 17 studies (89%) with 2065 knees (92%). In all, 13 knees were revised in the fixed bearing group and 14 knees in the mobile bearing group. No statistically significant differences were found (risk difference 0.00, 95% CI -0.01 to 0.01, P value 0.58), and homogeneous results were reported. MortalityIn seven out of 19 studies, 13 participants (37%) died. Two of these participants had undergone bilateral surgery, and for seven participants, it was unclear which prosthesis they had received; therefore they were excluded from the analyses. Thus our analysis included four out of 191 participants (2.1%) who had died: one in the fixed bearing group and three in the mobile bearing group. No statistically significant differences were found. The risk difference was -0.02 (95% CI -0.06 to 0.03, P value 0.49) and results were homogeneous. Reoperation ratesThirty reoperations were performed in 17 studies (89%) with 2065 knees (92%): 18 knees in the fixed bearing group (of the 1031 knees) and 12 knees in the mobile group (of the 1034 knees). No statistically significant differences were found. The risk difference was -0.01 (95% CI -0.01 to 0.01, P value 0.99) with homogeneous results. Other serious adverse eventsSixteen studies (84%) reported nine other serious adverse events in 1735 knees (77%): four in the fixed bearing group (of the 862 knees) and five in the mobile bearing group (of the 873 knees). No statistically significant differences were found (risk difference 0.00, 95% CI -0.01 to 0.01, P value 0.88), and results were homogeneous. Moderate- to low-quality evidence suggests that mobile bearing prostheses may have similar effects on knee pain, clinical and functional scores, health-related quality of life, revision surgery, mortality, reoperation rate and other serious adverse events compared with fixed bearing prostheses in posterior cruciate retaining TKA. Therefore we cannot draw firm conclusions. Most (98.5%) participants had OA, so the findings primarily reflect results reported in participants with OA. Future studies should report in greater detail outcomes such as those presented in this systematic review, with sufficient follow-up time to allow gathering of high-quality evidence and to inform clinical practice. Large registry-based studies may have added value, but they are subject to treatment-by-indication bias. Therefore, this systematic review of RCTs can be viewed as the best available evidence.

  16. Quantitative, Comparative Assessment of Gait Between Single-Radius and Multi-Radius Total Knee Arthroplasty Designs.

    PubMed

    Larsen, Bethany; Jacofsky, Marc C; Jacofsky, David J

    2015-06-01

    Gait of single-radius (SR, n=16) and multi-radius (MR, n=16) posterior stabilized total knee arthroplasties was compared, along with controls (n=16), pre-op and 1 year post-op. Computer navigation and standard order sets controlled confounding variables. Post-operatively, SR knees did not differ from controls while MR knees continued to differ in important knee kinetic and kinematic properties. MR knees remained more extended (P=0.019) and had decreased power absorption (P=0.0001) during weight acceptance compared to the SR knees. Both surgical groups had similar KSS for Knee Scores (P=0.22) and Function Scores (P=0.58). The significant biomechanical differences are likely influenced by patella-femoral moment arm geometry and changing ligament laxity throughout the active range of motion. Copyright © 2015 Elsevier Inc. All rights reserved.

  17. Human knee joint anatomy revisited: morphometry in the light of sex-specific total knee arthroplasty.

    PubMed

    Dargel, Jens; Michael, Joern W P; Feiser, Janna; Ivo, Roland; Koebke, Juergen

    2011-04-01

    This study investigates differences in the anatomy of male and female knee joints to contribute to the current debate on sex-specific total knee implants. Morphometric data were obtained from 60 human cadaver knees, and sex differences were calculated. All data were corrected for height, and male and female specimens presenting with an identical length of the femur were analyzed as matched pairs. Male linear knee joint dimensions were significantly larger when compared with females. When corrected for differences in height, medial-lateral dimensions of male knees were significantly larger than female; however, matched paired analysis did not prove these differences to be consistent. Although implant design should focus interindividual variations in knee joint anatomy, our data do not support the concept of a female-specific implant design. Copyright © 2011 Elsevier Inc. All rights reserved.

  18. The biomechanical effect of increased valgus on total knee arthroplasty: a cadaveric study.

    PubMed

    Bryant, Brandon J; Tilan, Justin U; McGarry, Michelle H; Takenaka, Nobuyuki; Kim, William C; Lee, Thay Q

    2014-04-01

    The effects of valgus load on cadaveric knees following total knee arthroplasty (TKA) were investigated using a custom testing system. TKAs were performed on 8 cadaveric knees and tested at 0°, 30°, and 60° knee flexion in both neutral and 5° valgus. Fuji pressure sensitive film was used to quantify contact areas and pressures and MCL strain was determined using a Microscribe digitizing system. Lateral tibiofemoral pressures increased (P < 0.05) at all knee flexion angles with valgus loading. Patellofemoral contact characteristics did not change significantly (P > 0.05). Significant increases in strain were observed along the anterior and posterior border of the MCL at all knee flexion angles. These findings suggest that valgus loading increases TKA joint contact pressures and MCL strain with increasing knee flexion which may increase implant instability. © 2014.

  19. Loosening of the total knee arthroplasty: detection by radionuclide bone scanning. [/sup 99m/Tc-methylene diphosphonate

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hunter, J.C.; Hattner, R.S.; Murray, W.R.

    1980-07-01

    Pain after total knee arthroplasty is a common clinical problem in orthopedics, and prosthetic loosening, often requiring surgical revision, is usually the etiology. Since standard clinical and radiographic diagnostic measures have not proven totally satisfactory, a study of the utility of bone scintigraphy to assess stability of the knee prosthesis was done. Thirty-five patients with 39 prostheses were studied. Seventeen patients with 21 total knee arthroplasties served as controls and were asymptomatic, were stable at surgery, or improved with conservative management. Eighteen knees in 18 symptomatic patients composed the experimental group. Of these, 11 knees were loose at surgery andmore » seven have had surgery recommended. Scintigrams of the knees were obtained using /sup 99m/Tc-MDP, and ranked 0-3 corresponding to increasingly abnormal localization by three observers. Highly significant differences were observed between the abnormal and control groups (p<0.001). Reciprocal changes in sensitivity and specificity with increasingly stringent criteria were shown. While it is apparent that the bone scan cannot be used as the sole diagnostic method for evaluation of prosthetic stability, it does seem to be a useful adjunct along with clinical criteria and radiographic studies.« less

  20. Knee Replacement - Multiple Languages

    MedlinePlus

    ... in a new window. Arabic (العربية) Expand Section Total Knee Replacement - العربية (Arabic) Bilingual PDF Health Information Translations Chinese, Simplified (Mandarin dialect) (简体中文) Expand Section Total Knee Replacement - 简体中文 (Chinese, Simplified (Mandarin dialect)) Bilingual PDF Health ...

  1. Knee arthrodesis in failed total knee arthroplasty with severe osteolysis and ipsilateral long-stem total hip arthroplasty.

    PubMed

    Sim, Jae Ang; Lee, Beom Koo; Kwak, Ji Hoon; Moon, Sung Hoon

    2009-02-01

    We report a case of knee fusion after a failed total knee arthroplasty (TKA) with severe osteolysis including the epicondyle and ipsilateral total hip arthroplasty (THA) with long Wagner revision stem (Sulzer Orthopedics, Baar, Switzerland). The conventional devices for arthrodesis were unavailable in this case because of the long Wagner revision stem and poor bone stock. A connector was made between the long Wagner revision stem and an intramedullary nail (IM nail; Solco, Seoul, Korea). The custom-made connector was coupled with a femoral stem by cylindrical taper fit with additional cement augmentation and an intramedullary nail by screws. Osseous fusion was achieved without pain or instability.

  2. Arthroscopic treatment of patients with moderate arthrofibrosis after total knee replacement.

    PubMed

    Jerosch, Joerg; Aldawoudy, Akram M

    2007-01-01

    The purpose of this study was to document the effect of arthroscopic management in patients with knee stiffness after total knee replacement. We present a case series study, in which 32 patients have been treated for moderate arthrofibrosis of the knee after total knee replacement, with the same regimen. We have excluded all cases of stiffness, because of infection, mechanical mal-alignment, loosening of the implants and other obvious reasons of stiffness of the knee, rather than pure arthrofibrosis. All patients first underwent a trial of conservative treatment before going for arthroscopic management. A pain catheter for femoral nerve block was inserted just before anesthesia for post-operative pain management. Arthroscopic arthrolysis of the intra-articular pathology was performed in a standardized technique with release of all fibrous bands in the suprapatellar pouch, reestablishing the medial and lateral gutter, release of the patella, resection of the remaining meniscal tissue or an anterior cyclops, if needed. Intensive physiotherapy and continuous passive motion were to start immediately post-operatively. All the patients were available for the follow up and they were evaluated using the knee society rating system. A total of 25 of the 32 procedures resulted in an improvement of the patients knee score. All the knees operated upon had intra-articular fibrous bands, hypertrophic synovitis and peri-patellar adhesions. A total of eight patients suffered from an anterior cyclops lesion and six patients showed pseudomenicus. In 19 cases a medial and lateral relapse of the patella was performed; only 5 patients got an isolated lateral release. The mean knee flexion was 119 degrees (100-130) at the end of arthroscopy and was 97 degrees (75-115) at the last follow up. The eight patients with extension lags decreased from 27 degrees (10 degrees-35 degrees) pre-operatively to 4 degrees (0-10) at time of follow up. The average knee society ratings increased from 70 points prior to the arthroscopy to 86 at time of follow up, which was found to be statistically significant (P < 0.01, student's t test). The average function score also showed improvement from 68 points pre-operatively to 85 at the time of final follow up. The average pain scores improved from 30 points pre-operatively to 41 at the time of final follow up. Our results showed that arthroscopic management of knee stiffness following total knee replacement is a safe and efficient method of treatment. Pain and functional knee scores can improve markedly.

  3. Improved knee biomechanics among patients reporting a good outcome in knee-related quality of life one year after total knee arthroplasty.

    PubMed

    Naili, Josefine E; Wretenberg, Per; Lindgren, Viktor; Iversen, Maura D; Hedström, Margareta; Broström, Eva W

    2017-03-21

    It is not well understood why one in five patients report poor outcomes following knee arthroplasty. This study evaluated changes in knee biomechanics, and perceived pain among patients reporting either a good or a poor outcome in knee-related quality of life after total knee arthroplasty. Twenty-eight patients (mean age 66 (SD 7) years) were included in this prospective study. Within one month of knee arthroplasty and one year after surgery, patients underwent three-dimensional (3D) gait analysis, completed the Knee Injury and Osteoarthritis Outcome Score (KOOS), and rated perceived pain using a visual analogue scale. A "good outcome" was defined as a change greater than the minimally detectable change in the KOOS knee-related quality of life, and a "poor outcome" was defined as change below the minimally detectable change. Nineteen patients (68%) were classified as having a good outcome. Groups were analyzed separately and knee biomechanics were compared using a two-way repeated measures ANOVA. Differences in pain between groups were evaluated using Mann Whitney U test. Patients classified as having a good outcome improved significantly in most knee gait biomechanical outcomes including increased knee flexion-extension range, reduced peak varus angle, increased peak flexion moment, and reduced peak valgus moment. The good outcome group also displayed a significant increase in walking speed, a reduction (normalization) of stance phase duration (% of gait cycle) and increased passive knee extension. Whereas, the only change in knee biomechanics, one year after surgery, for patients classified as having a poor outcome was a significant reduction in peak varus angle. No differences in pain postoperatively were found between groups. Patients reporting a good outcome in knee-related quality of life improved in knee biomechanics during gait, while patients reporting a poor outcome, despite similar reduction in pain, remained unchanged in knee biomechanics one year after total knee arthroplasty. With regards to surgeon-controlled biomechanical factors, surgery may most successfully address frontal plane knee alignment. However, achieving a good outcome in patient-reported knee-related quality of life may be related to dynamic improvements in the sagittal plane.

  4. Radiographic assessment of knee-ankle alignment after total knee arthroplasty for varus and valgus knee osteoarthritis.

    PubMed

    Gao, Fuqiang; Ma, Jinhui; Sun, Wei; Guo, Wanshou; Li, Zirong; Wang, Weiguo

    2017-01-01

    There are unanswered questions about knee-ankle alignment after total knee arthroplasty (TKA) for varus and valgus osteoarthritis (OA) of the knee. The aim of this retrospective study was to assess knee-ankle alignment after TKA. The study consisted of 149 patients who had undergone TKA due to varus and valgus knee OA. The alignment and angles in the selected knees and ankles were measured on full-length standing anteroposterior radiographs, both pre-operatively and post-operatively. The paired t-test and Pearson's correlation tests were used for statistical analysis. The results showed that ankle alignment correlated with knee alignment both pre-operatively and postoperatively (P<0.05). The pre-operative malalignment of the knee was corrected (P<0.05), and the ankle tilt angle was accordingly improved in the operative side after TKA (P<0.05). In addition, TKA had little effect on knee-ankle alignment on the non-operative side (P>0.05). These findings indicated that routine TKA could correct the varus or valgus deformity of a knee, and improve the tilt of the ankle. Ankle alignment correlated with knee alignment both pre-operatively and postoperatively. Both pre-operative knee and ankle malalignment can be simultaneously corrected following TKA. Level III. Copyright © 2016 Elsevier B.V. All rights reserved.

  5. Recent Advances and Developments in Knee Surgery: Principles of Periprosthetic Knee Fracture Management

    PubMed Central

    Chimutengwende-Gordon, Mukai; Khan, Wasim; Johnstone, David

    2012-01-01

    The management of distal femoral, tibial and patellar fractures after total knee arthroplasty can be complex. The incidence of these fractures is increasing as the number of total knee arthroplasties being performed and patient longevity is increasing. There is a wide range of treatment options including revision arthroplasty for loose implants. This review article discusses the epidemiology, risk factors, classification and treatment of these fractures. PMID:22888380

  6. Simultaneous mobile- and fixed-bearing total knee replacement in the same patients. A prospective comparison of mid-term outcomes using a similar design of prosthesis.

    PubMed

    Kim, Y-H; Kim, D-Y; Kim, J-S

    2007-07-01

    We conducted a randomised prospective study to evaluate the clinical and radiological results of a mobile- and fixed-bearing total knee replacement of similar design in 174 patients who had bilateral simultaneous knee replacement. The mean follow-up was for 5.6 years (5.2 to 6.1). The total knee score, pain score, functional score and range of movement were not statistically different (p > 0.05) between the two groups. Osteolysis was not seen in any knee in either group. Two knees (1%) in the mobile-bearing group required revision because of infection; none in the fixed-bearing group needed revision. Excellent results can be achieved with both mobile- and fixed-bearing prostheses of similar design at mid-term follow-up. We could demonstrate no significant clinical advantage for a mobile bearing.

  7. Kinematic and kinetic analysis of the knee joint before and after a PCL retaining total knee replacement during gait and single step ascent.

    PubMed

    Apostolopoulos, Alexandros; Lallos, Stergios; Mastrokalos, Dimitrios; Michos, Ioannis; Darras, Nikolaos; Tzomaki, Magda; Efstathopoulos, Nikolaos

    2011-01-01

    The objective of this study was to capture and analyze the kinetics and kinematics and determine the functional performance of the osteoarthritic knee after a posterior cruciate ligament (PCL) retaining total knee arthroplasty. Kinematic and kinetic gait analysis of level walking was performed in 20 subjects (12 female and 8 male) with knee ostoarthritis. These patients were free of any neurological diseases that could affect their normal gait. Mean age was 69.6 ± 6.6 years; mean height was 157.6 cm ± 7.6 cm; and mean weight was 77.2 ± 12.1 kg. Full body gait analyses were performed using the BIOKIN 3D motion analysis system before and 9 months after total knee arthroplasty procedures. Single-step ascending kinetic analyses and plantar pressure distribution analyses were also performed for all subjects. International Knee Society Scores (IKSSs) were also assessed pre- and postoperatively. Significant increases were noted postoperatively in average cadence (preoperative mean = 99.26, postoperative mean = 110.5; p < 0.004), step length (preoperative mean = 0.49, postoperative mean = 0.54; p < 0.01) , and walking velocity (preoperative mean = 0.78, preoperatively, postoperative mean = 0.99; p < 0.001). Decreases in stance duration percentage and knee adduction moment were also reported postoperatively. All patients showed a significant improvement of knee kinetics and kinematics after a PCL retaining total knee arthroplasty. Significant differences were found in the cadence, step length, stride length, and walk velocity postoperatively. IKSSs also significantly improved. Further research is warranted to determine the clinical relevance of these findings.

  8. Atraumatic haemarthrosis following total knee replacement treated with selective embolisation.

    PubMed

    Karataglis, Dimitrios; Marlow, Duncan; Learmonth, Duncan J A

    2006-06-01

    Spontaneous haemarthrosis in the absence of anticoagulant medication or a bleeding disorder is a very rare complication after total knee arthroplasty. A case of recurrent spontaneous haemarthrosis following total knee replacement in a 69-year-old patient is reported. Angiography was used to aid the diagnosis. It demonstrated an abnormal blush of vessels around the anterior aspect of the knee joint, that was fed by genicular branches and a recurrent branch of the anterior tibial artery. Selective embolisation of the bleeding vessels with coils led to immediate control of the bleeding. No further recurrence of haemarthrosis has been recorded.

  9. Knee arthrodesis as limb salvage for complex failures of total knee arthroplasty.

    PubMed

    Kuchinad, Raul; Fourman, Mitchell S; Fragomen, Austin T; Rozbruch, S Robert

    2014-11-01

    Patients with multiple failures of total knee arthroplasty (TKA) are challenging limb salvage cases. Twenty one patients over the last 10 years were referred to our service for knee fusion by arthroplasty surgeons who felt they were not candidates for revision TKA. Active infection was present in 76.2% and total bone loss averaged 6.6 cm. Lengthening was performed in 7/22 patients. Total time in Ilizarov frames was 9 months, with 93.3% union. Patients treated with IM fusion nails had 100% union. Average LLD increased from 3.6 to 4.5 cm following intervention, while those with concurrent lengthening improved to 1.6 cm. Findings suggest that bone loss and the soft-tissue envelope dictate knee fusion method, and multiple techniques may be needed. A treatment algorithm is presented. Copyright © 2014 Elsevier Inc. All rights reserved.

  10. Posterior cruciate-retaining versus posterior-stabilized total knee arthroplasty for osteoarthritis with severe varus deformity.

    PubMed

    Ünkar, Ethem Ayhan; Öztürkmen, Yusuf; Şükür, Erhan; Çarkçı, Engin; Mert, Murat

    2017-03-01

    The aim of this study was to compare the radiological and functional results of posterior cruciate ligament (PCL) - retaining and posterior-stabilized total knee arthroplasties in patients with severe varus gonarthrosis. Medical records of 112 knees of 96 patients who underwent total knee arthroplasty for severe varus (≥15°) were reviewed. PCL-retaining and PCL-stabilizing groups consisted of 58 and 54 knees, respectively. Mean follow-up time was 56.6 months (range: 24-112 months). Knee Society (KS) clinical rating system was used in clinical evaluation. Range of motion, degree of flexion contracture, postoperative alignment, and complication rates were compared between the groups. Mean preoperative mechanical tibiofemoral angle was 20.1° in varus alignment, and was restored to 4.6° in valgus postoperatively. No statistically significant differences were found between PCL-stabilizing and PCL-retaining groups when KS knee scores, function scores, and flexion arc were evaluated. Two patients in PCL-retaining group underwent revision surgery due to aseptic loosening of tibial component. One patient in PCL-stabilizing group needed arthrotomy due to patellar clunk syndrome. There were no notable differences between the 2 groups and PCL-retaining design had outcomes as good as PCL-stabilizing total knee implant in osteoarthritic knees with severe varus deformity. Level III, Therapeutic study. Copyright © 2016 Turkish Association of Orthopaedics and Traumatology. Production and hosting by Elsevier B.V. All rights reserved.

  11. Clinical and biomechanical assessment of patella resurfacing in total knee arthroplasty.

    PubMed

    Berti, Lisa; Benedetti, Maria Grazia; Ensini, Andrea; Catani, Fabio; Giannini, Sandro

    2006-07-01

    Currently there is a limited understanding of the factors influencing range of motion by comparing patellar resurfacing vs non-resurfacing in total knee arthroplasty during activities of daily living. A recent meta-analysis of patellar replacement confirms better outcome with patella resurfacing; however, the result can be influenced by many other factors, such as: component design, surgeon experience, and technical aspects of the surgery. This study compares the biomechanics of the knee in patients after total knee arthroplasty with and without patellar resurfacing during stair climbing. Forty-seven patients with total knee arthroplasty were assessed at the mean follow-up of 24 months. In all of them a posterior stabilised fixed bearing prosthesis (Optetrak PS, Exactech) was implanted. Twenty-six patients were treated without patellar resurfacing and 21 with patellar resurfacing. Clinical evaluations were performed using the International Knee Society and the Hospital for Special Surgery scores. Ten patients with patellar resurfacing and 10 patients without patellar resurfacing were also studied with motion analysis during stair climbing; 10 healthy subjects were studied for statistical comparison. Clinical passive knee flexion, International Knee Society Function and Hospital for Special Surgery scores were significantly higher in the patellar resurfacing group. During stair climbing, active knee joint range of motion during the stance phase was greater in patients with patellar resurfacing. The maximum adduction moment was significantly higher in the group without patellar resurfacing. Patients with patellar resurfacing demonstrated better clinical scores, and kinematic and kinetic data while ascending stairs.

  12. [EFFECTIVENESS OF BILATERAL TOTAL HIP AND KNEE ARTHROPLASTY FOR SEVERE INFLAMMATORY ARTHROPATHIES].

    PubMed

    Li, Xin; Li, Heng; Ni, Ming; Li, Xiang; Song, Xinggui; Kong, Xiangpeng; Li, Yucong; Chen, Jiying

    2016-11-08

    To evaluate the application and effectiveness of bilateral total hip arthroplasty and total knee arthroplasty in the treatment of severe inflammatory arthropathies. Between September 2008 and September 2015, 31 patients with severe inflammatory arthropathies were treated with bilateral total hip arthroplasty and total knee arthroplasty. Of 31 cases, 22 were male and 9 were female with an average age of 30 years (range, 20 to 41 years); there were 15 cases of rheumatoid arthritis and 16 cases of ankylosing spondylitis with an average onset age of 14 years (range, 5-28 years); all 4 ankylosed joints were observed in 11 cases, 3 ankylosed joints in 2 cases, 2 ankylosed joints in 6 cases, 1 ankylosed joint in 1 case, and no ankylosed joint in 11 cases. Before operation, the hip range of motion (ROM) value was (17.82±28.18)°, and the knee ROM value score was (26.45±30.18)°; the hip Harris score was 29.64±11.58, and the hospital for special surgery (HSS) score was 27.07±11.04. The patients were grouped and compared in accordance with etiology and ankylosed joint. One-stage arthroplasty was performed in 1 case, two-stage arthroplasty in 22 cases, three-stage arthroplasty in 7 cases, and four-stage arthroplasty in 1 case. The total operation time was 325-776 minutes; the total blood loss was 900-3 900 mL; the total transfusion volume was 2 220-8 070 mL; and the total hospitalization time was 21-65 days. The patients were followed up 12-94 months (mean, 51 months). The hip and knee ROM values, Harris score and HSS score at last follow-up were significantly improved when compared with preoperative ones ( P <0.05). The subjective satisfaction degree was good in 16 cases, moderate in 10 cases, and poor in 5 cases. Periprosthetic infection occurred in 2 cases (3 knees), joint stiffness in 3 cases (6 knees), joint instability in 1 case (1 knee), leg length discrepancy of >2 cm in 2 cases, and flexion deformity of 10° in 1 case (1 knee). The hip and knee ROM values, Harris score and HSS score showed no significant difference between patients with ankylosing spondylitis and patients rheumatoid arthritis at last follow-up ( P >0.05). The hip and knee ROM values of the patients with ankylosed joint were significantly lower than those of patients with no ankylosed joint ( P <0.05); the Harris score and HSS score of the patients with ankylosed joint were lower than those of patients with no ankylosed joint, but no significant difference was found ( P >0.05). A combination of bilateral hip and knee arthroplasty is an efficient treatment for severe lower extremities deformity, arthralgia and poor quality of life caused by inflammatory arthropathies. However, the postoperative periprosthetic infection and stiffness of knee are important complications influencing the effectiveness of operation.

  13. Comparison of topical versus intravenous tranexamic acid in primary total knee arthroplasty: a meta-analysis of randomized controlled and prospective cohort trials.

    PubMed

    Wang, Hao; Shen, Bin; Zeng, Yi

    2014-12-01

    There has been much debate and controversy about the optimal regimen of tranexamic acid in primary total knee arthroplasty. The purpose of this study was to undertake a meta-analysis to compare the efficacy of topical and intravenous regimen of tranexamic acid in primary total knee arthroplasty. A systematic review of the electronic databases PubMed, CENTRAL, Web of Science, and Embase was undertaken. All randomized controlled trials and prospective cohort studies evaluating the effectiveness of topical and intravenous tranexamic acid during primary total knee arthroplasty were included. The focus of the analysis was on the outcomes of blood loss, transfusion rate, and thromboembolic complications. Subgroup analysis was performed when possible. Of 328 papers identified, six trials were eligible for data extraction and meta-analysis comprising 679 patients (739 knees). We found no statistically significant difference between topical and intravenous administration of tranexamic acid in terms of blood loss, transfusion requirements and thromboembolic complications. Topical tranexamic acid has a similar efficacy to intravenous tranexamic acid in reducing both blood loss and transfusion rate without sacrificing safety in primary total knee arthroplasty. II. Copyright © 2014 Elsevier B.V. All rights reserved.

  14. Comparison of cemented and uncemented fixation in total knee arthroplasty.

    PubMed

    Brown, Thomas E; Harper, Benjamin L; Bjorgul, Kristian

    2013-05-01

    As a result of reading this article, physicians should be able to :1. Understand the rationale behind using uncemented fixation in total knee arthroplasty.2.Discuss the current literature comparing cemented and uncemented total knee arthroplasty3. Describe the value of radiostereographic analysis in assessing implant stability.4. Appreciate the limitations in the available literature advocating 1 mode of fixation in total knee arthroplasty. Total knee arthroplasty performed worldwide uses either cemented, cementless, or hybrid (cementless femur with a cemented tibia) fixation of the components. No recent literature review concerning the outcomes of cemented vs noncemented components has been performed. Noncemented components offer the potential advantage of a biologic interface between the bone and implants, which could demonstrate the greatest advantage in long-term durable fixation in the follow-up of young patients undergoing arthroplasty. Several advances have been made in the backing of the tibial components that have not been available long enough to yield long-term comparative follow-up studies. Short-term radiostereographic analysis studies have yielded differing results. Although long-term, high-quality studies are still needed, material advances in biologic fixation surfaces, such as trabecular metal and hydroxyapatite, may offer promising results for young and active patients undergoing total knee arthroplasty when compared with traditional cemented options. Copyright 2013, SLACK Incorporated.

  15. Lower limb joint moment during walking in water.

    PubMed

    Miyoshi, Tasuku; Shirota, Takashi; Yamamoto, Shin-Ichiro; Nakazawa, Kimitaka; Akai, Masami

    2003-11-04

    Walking in water is a widely used rehabilitation method for patients with orthopedic disorders or arthritis, based on the belief that the reduction of weight in water makes it a safer medium and prevents secondary injuries of the lower-limb joints. To our knowledge, however, no experimental data on lower-limb joint moment during walking in water is available. The aim of this study was to quantify the joint moments of the ankle, knee, and hip during walking in water in comparison with those on land. Eight healthy volunteers walked on land and in water at a speed comfortable for them. A video-motion analysis system and waterproof force platform were used to obtain kinematic data and to calculate the joint moments. The hip joint moment was shown to be an extension moment almost throughout the stance phase during walking in water, while it changed from an extension- to flexion-direction during walking on land. The knee joint moment had two extension peaks during walking on land, whereas it had only one extension peak, a late one, during walking in water. The ankle joint moment during walking in water was considerably reduced but in the same direction, plantarflexion, as that during walking on land. The joint moments of the hip, knee, and ankle were not merely reduced during walking in water; rather, inter-joint coordination was totally changed.

  16. Human Gait and Postural Control after Unilateral Total Knee Arthroplasty

    PubMed Central

    STAN, Gabriel; ORBAN, Horia

    2014-01-01

    Introduction: This study assesses the changes in human gait in the early postoperative phase of unilateral TKA, by evaluating the variability of free moment. Materials and method: The study group consisted of 10 patients from the Orthopedic Department of the 'Elias' University Hospital in Bucharest who undergone unilateral knee arthroplasty with the same type of posterior cruciate ligament substituting prosthesis. For the evaluation of free moment an AMTI AccuGait force platform was used. Results: Regarding the free moment peaks, for the operated and non-operated limb, increased significantly (p <0.05) in the postoperative period. The stance time was higher post-surgery for both limbs. Discussion: In the early postoperative phase of unilateral TKA, free moment is higher on both the operated and the non-operated limbs, which means that the knees are subjected to higher torques. Shortly after TKA, patients tend to walk with lower speed, with small steps and reduced cadence. Stance time differences between the operated and the non-operated limbs can lead to overuse of the latter, worsening its condition. Conclusions: It is highly important to adopt a well-managed rehabilitation program in order to increase walking stability. The cost effectiveness of this procedure could be highly dependent on the rehab program. The parameters studied in this article are useful in assessing the rehabilitation protocol. PMID:25705305

  17. Gender comparisons between unilateral and bilateral landings.

    PubMed

    Weinhandl, Joshua T; Joshi, Mukta; O'Connor, Kristian M

    2010-11-01

    The increased number of women participating in sports has led to a higher knee injury rate in women compared with men. Among these injuries, those occurring to the ACL are commonly observed during landing maneuvers. The purpose of this study was to determine gender differences in landing strategies during unilateral and bilateral landings. Sixteen male and 17 female recreational athletes were recruited to perform unilateral and bilateral landings from a raised platform, scaled to match their individual jumping abilities. Three-dimensional kinematics and kinetics of the dominant leg were calculated during the landing phase and reported as initial ground contact angle, ranges of motion (ROM) and peak moments. Lower extremity energy absorption was also calculated for the duration of the landing phase. Results showed that gender differences were only observed in sagittal plane hip and knee ROM, potentially due to the use of a relative drop height versus the commonly used absolute drop height. Unilateral landings were characterized by significant differences in hip and knee kinematics that have been linked to increased injury risk and would best be classified as "stiff" landings. The ankle musculature was used more for impact absorption during unilateral landing, which required increased joint extension at touchdown and may increase injury risk during an unbalanced landing. In addition, there was only an 11% increase in total energy absorption during unilateral landings, suggesting that there was a substantial amount of passive energy transfer during unilateral landings.

  18. Avulsion of the fibular head post-total knee replacement.

    PubMed

    Phadnis, Ashish; Johnston, Phillip; Glasgow, Malcom

    2007-11-01

    We report a case of an avulsion of part of the fibular head during a primary total knee replacement for osteoarthritis. Post-operatively the patient developed a foot-drop. However, there was no clinically demonstrable instability of the knee. The patient was managed conservatively, the foot-drop recovered completely and the knee remained clinically stable. We observed that excessive hyperextension and/or a varus strain on the knee during pressurisation while cementing could have led to the injury. We advise caution while using this manoeuvre for pressurisation. This is the first injury of its kind reported in the literature.

  19. Influence of Total Knee Arthroplasty on Gait Mechanics of the Replaced and Non-Replaced Limb During Stair Negotiation.

    PubMed

    Standifird, Tyler W; Saxton, Arnold M; Coe, Dawn P; Cates, Harold E; Reinbolt, Jeffrey A; Zhang, Songning

    2016-01-01

    This study compared biomechanics during stair ascent in replaced and non-replaced limbs of total knee arthroplasty (TKA) patients with control limbs of healthy participants. Thirteen TKA patients and fifteen controls performed stair ascent. Replaced and non-replaced knees of TKA patients were less flexed at contact compared to controls. The loading response peak knee extension moment was greater in control and non-replaced knees compared with replaced. The push-off peak knee abduction moment was elevated in replaced limbs compared to controls. Loading and push-off peak hip abduction moments were greater in replaced limbs compared to controls. The push-off peak hip abduction moment was greater in non-replaced limbs compared to controls. Future rehabilitation protocols should consider the replaced knee and also the non-replaced knee and surrounding joints. Copyright © 2016 Elsevier Inc. All rights reserved.

  20. Continuous femoral versus epidural block for attainment of 120° knee flexion after total knee arthroplasty: a randomized controlled trial.

    PubMed

    Sakai, Norihiro; Inoue, Takaya; Kunugiza, Yasuo; Tomita, Tetsuya; Mashimo, Takashi

    2013-05-01

    We conducted the prospective randomized controlled trial to test that continuous femoral nerve block (CFNB) improves attainment of 120° knee flexion compared to continuous epidural analgesia (CEA). Sixty-six patients scheduled for unilateral total knee arthroplasty were randomized into two groups; infusion of ropivacaine 0.15% into CEA or CFNB to third postoperative days. We studied the time required to attain 120° knee flexion, variations in thigh and calf circumferences around the treated knee, pain scores, rehabilitation milestones, the need for adjuvant analgesics, and side effects. CFNB patients attained earlier knee flexion to 120°, lower variations in thigh and calf circumferences, less pain during rehabilitation, and less need for adjuvant analgesics. CFNB is a better pain management strategy that accelerates knee flexion rehabilitation. Copyright © 2013 Elsevier Inc. All rights reserved.

  1. Differences in the stress distribution in the distal femur between patellofemoral joint replacement and total knee replacement: a finite element study

    PubMed Central

    2012-01-01

    Background Patellofemoral joint replacement is a successful treatment option for isolated patellofemoral osteoarthritis. However, results of later conversion to total knee replacement may be compromised by periprosthetic bone loss. Previous clinical studies have demonstrated a decrease in distal femoral bone mineral density after patellofemoral joint replacement. It is unclear whether this is due to periprosthetic stress shielding. The main objective of the current study was to evaluate the stress shielding effect of prosthetic replacement with 2 different patellofemoral prosthetic designs and with a total knee prosthesis. Methods We developed a finite element model of an intact patellofemoral joint, and finite element models of patellofemoral joint replacement with a Journey PFJ prosthesis, a Richards II prosthesis, and a Genesis II total knee prosthesis. For each of these 4 finite element models, the average Von Mises stress in 2 clinically relevant regions of interest were evaluated during a simulated squatting movement until 120 degrees of flexion. Results During deep knee flexion, in the anterior region of interest, the average Von Mises stress with the Journey PFJ design was comparable to the physiological knee, while reduced by almost 25% for both the Richards II design and the Genesis II total knee joint replacement design. The average Von Mises stress in the supracondylar region of interest was similar for both patellofemoral prosthetic designs and the physiological model, with slightly lower stress for the Genesis II design. Conclusions Patellofemoral joint replacement results in periprosthetic stress-shielding, although to a smaller degree than in total knee replacement. Specific patellofemoral prosthetic design properties may result in differences in femoral stress shielding. PMID:22704638

  2. Repeat Manipulation Under Anesthesia For Persistent Stiffness After Total Knee Arthroplasty Achieves Functional Range of Motion.

    PubMed

    Ferrel, Jason R; Davis, Richard L; Agha, Obiajulu A J C; Politi, Joel R

    2015-05-01

    Poor range of motion may decrease a patient's ability to participate in activities of daily living after total knee arthroplasty. Manipulation under anesthesia has been shown to improve range of motion; however, some patients have persistent stiffness even after manipulation. The goal of this study was to evaluate the outcomes and complications of patients who underwent a second manipulation under anesthesia for persistent stiffness after total knee arthroplasty. The review of surgical records of two joint arthroplasty surgeons identified 226 knees in 210 patients who underwent a manipulation under anesthesia for poor range of motion after total knee arthroplasty. Of these patients, 16 patients underwent a second manipulation under anesthesia. For patients undergoing two manipulations under anesthesia procedures, at latest follow up (mean 539 days), mean extension improved from 10.50° to 2.50° (p=0.001) and mean flexion improved from 87.50° to 112.69° (p=0.001) respectively. SF-12 scores were available for 12 of 16 knees with a mean score of 34.42. Two of 16 patients (12.5%) experienced a complication. Three of 16 (18.8%) patients who underwent a second manipulation required a revision arthroplasty procedure. In conclusion, a second manipulation under anesthesia can achieve functional range of motion that is sustained after total knee arthroplasty.

  3. Lower Limbs Function and Pain Relationships after Unilateral Total Knee Arthroplasty

    ERIC Educational Resources Information Center

    Tali, Maie; Maaroos, Jaak

    2010-01-01

    The aim of the study was to evaluate gait characteristics, lower limbs joint function, and pain relationships associated with knee osteoarthritis of female patients before and 3 months after total knee arthroplasty at an outpatient clinic rehabilitation department. Gait parameters were registered, the active range of lower extremity joints was…

  4. Historical view and future demand for knee arthroplasty in Sweden

    PubMed Central

    Rolfson, Ola; W-Dahl, Annette; Garellick, Göran; Sundberg, Martin; Kärrholm, Johan; Robertsson, Otto

    2015-01-01

    Background and purpose The incidence of knee osteoarthritis will most likely increase. We analyzed historical trends in the incidence of knee arthroplasty in Sweden between 1975 and 2013, in order to be able to provide projections of future demand. Patients and methods We obtained information on all knee arthroplasties in Sweden in the period 1975–2013 from the Swedish Knee Arthroplasty Register, and used public domain data from Statistics Sweden on the evolution of and forecasts for the Swedish population. We forecast the incidence, presuming the existence of a maximum incidence. Results We found that the incidence of knee arthroplasty will continue to increase until a projected upper incidence level of about 469 total knee replacements per 105 Swedish residents aged 40 years and older is reached around the year 2130. In 2020, the estimated incidence of total knee arthroplasties per 105 Swedish residents aged 40 years and older will be 334 (95% prediction interval (PI): 281–374) and in 2030 it will be 382 (PI: 308–441). Using officially forecast population growth data, around 17,500 operations would be expected to be performed in 2020 and around 21,700 would be expected to be performed in 2030. Interpretation Today’s levels of knee arthroplasty are well below the expected maximum incidence, and we expect a continued annual increase in the total number of knee arthroplasties performed. PMID:25806653

  5. Estimating patient-specific soft-tissue properties in a TKA knee.

    PubMed

    Ewing, Joseph A; Kaufman, Michelle K; Hutter, Erin E; Granger, Jeffrey F; Beal, Matthew D; Piazza, Stephen J; Siston, Robert A

    2016-03-01

    Surgical technique is one factor that has been identified as critical to success of total knee arthroplasty. Researchers have shown that computer simulations can aid in determining how decisions in the operating room generally affect post-operative outcomes. However, to use simulations to make clinically relevant predictions about knee forces and motions for a specific total knee patient, patient-specific models are needed. This study introduces a methodology for estimating knee soft-tissue properties of an individual total knee patient. A custom surgical navigation system and stability device were used to measure the force-displacement relationship of the knee. Soft-tissue properties were estimated using a parameter optimization that matched simulated tibiofemoral kinematics with experimental tibiofemoral kinematics. Simulations using optimized ligament properties had an average root mean square error of 3.5° across all tests while simulations using generic ligament properties taken from literature had an average root mean square error of 8.4°. Specimens showed large variability among ligament properties regardless of similarities in prosthetic component alignment and measured knee laxity. These results demonstrate the importance of soft-tissue properties in determining knee stability, and suggest that to make clinically relevant predictions of post-operative knee motions and forces using computer simulations, patient-specific soft-tissue properties are needed. © 2015 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  6. Excellent Survival and Good Outcomes at 15 Years Using the Press-Fit Condylar Sigma Total Knee Arthroplasty.

    PubMed

    Oliver, William M; Arthur, Calum H C; Wood, Alexander M; Clayton, Robert A E; Brenkel, Ivan J; Walmsley, Philip

    2018-03-27

    We report 15-year survival, clinical, and radiographic follow-up data for the Press-Fit Condylar Sigma total knee arthroplasty. Between October 1998 and October 1999, 235 consecutive TKAs were performed in 203 patients. Patients were reviewed at a specialist nurse-led clinic before surgery and at 5, 8-10, and 15 years postoperatively. Clinical outcomes, including Knee Society Score, were recorded prospectively at each clinic visit, and radiographs were obtained. Of our initial cohort, 99 patients (118 knees) were alive at 15 years, and 31 patients (34 knees) were lost to follow-up. Thirteen knees (5.5%) were revised; 5 (2.1%) for infection, 7 (3%) for instability, and 1 (0.4%) for aseptic loosening. Cumulative survival with the end point of revision for any reason was 92.3% at 15 years and with revision for aseptic failure as the end point was 94.4%. The mean Knee Society Score knee score was 77.4 (33-99) at 15 years, compared with 31.7 (2-62) preoperatively. Of 71 surviving knees for which X-rays were available, 12 (16.9%) had radiolucent lines and 1 (1.4%) demonstrated clear radiographic evidence of loosening. The Press-Fit Condylar Sigma total knee arthroplasty represents a durable, effective option for patients undergoing knee arthroplasty, with excellent survival and good clinical and radiographic outcomes at 15 years. Copyright © 2018 Elsevier Inc. All rights reserved.

  7. Ground reaction forces and knee mechanics in the weight acceptance phase of a dance leap take-off and landing.

    PubMed

    Kulig, Kornelia; Fietzer, Abbigail L; Popovich, John M

    2011-01-01

    Aesthetic constraints allow dancers fewer technique modifications than other athletes to negotiate the demands of leaping. We examined vertical ground reaction force and knee mechanics during a saut de chat performed by healthy dancers. It was hypothesized that vertical ground reaction force during landing would exceed that of take-off, resulting in greater knee extensor moments and greater knee angular stiffness. Twelve dancers (six males, six females; age 18.9 ± 1.2 years, mass 59.2 ± 9.5 kg, height 1.68 ± 0.08 m, dance training 8.9 ± 5.1 years) with no history of low back pain or lower extremity pathology participated in the study. Saut de chat data were captured using an eight-camera Vicon system and AMTI force platforms. Peak ground reaction force was 26% greater during the landing phase, but did not result in increased peak knee extensor moments. Taking into account the 67% greater knee angular displacement during landing, this resulted in less knee angular stiffness during landing. In conclusion, landing was accomplished with less knee angular stiffness despite the greater peak ground reaction force. A link between decreased joint angular stiffness and increased soft tissue injury risk has been proposed elsewhere; therefore, landing from a saut de chat may be more injurious to the knee soft tissue than take-off.

  8. Characterizing Knee Loading Asymmetry in Individuals Following Anterior Cruciate Ligament Reconstruction Using Inertial Sensors

    PubMed Central

    Sigward, Susan M.; Chan, Ming-Sheng M.; Lin, Paige E.

    2016-01-01

    Limitations in the ability to identify knee extensor loading deficits during gait in individuals following anterior cruciate ligament reconstruction (ACLr) may underlie their persistence. A recent study suggested that shank angular velocity, directly output from inertial sensors, differed during gait between individuals post-ACLr and controls. However, it is not clear if this kinematic variable relates to knee moments calculated using joint kinematics and ground reaction forces. Heel rocker mechanics during loading response of gait, characterized by rapid shank rotation, require knee extensor control. Measures of shank angular velocity may be reflective of knee moments. This study investigated the relationship between shank angular velocity and knee extensor moment during gait in individuals (n=19) 96.7±16.8 days post-ACLr. Gait was assessed concurrently using inertial sensors and a marker-based motion system with force platforms. Peak angular velocity and knee extensor moment were strongly correlated (r=0.75, p<0.001) and between limb ratios of angular velocity predicted between limb ratios of extensor moment (r2=0.57 ,p<0.001) in the absence of between limb differences in spatiotemporal gait parameters. The strength of these relationships indicate that shank kinematic data offer meaningful information regarding knee loading and provide a potential alternative to full motion analysis systems for identification of altered knee loading following ACLr PMID:27395452

  9. Detection of total knee prostheses at airport security checkpoints.

    PubMed

    Naziri, Qais; Johnson, Aaron J; Hooper, Hasan A; Sana, Said H; Mont, Michael A

    2012-06-01

    Airport security screening measures have changed substantially during the past decade, but few reports have examined how this affects patients who have undergone knee arthroplasties. The purpose of this study was to characterize the efficacy of airport metal detection of total knee prostheses, the delays faced, any inconvenience this may have caused, and the role of implant identification cards. Ninety-seven total knee arthroplasty recipients reported passing through an airport metal detector, with 70 triggering the alarm a mean of 3 times (range, 1-36). The presence of a single-knee prosthesis triggered airport security alarms more than 83% of the time and increased patient inconvenience. Patients should be informed about this chance and be prepared to present documentation of their prosthesis. Copyright © 2012 Elsevier Inc. All rights reserved.

  10. Data Collection and Analysis Using Wearable Sensors for Monitoring Knee Range of Motion after Total Knee Arthroplasty

    PubMed Central

    Chiang, Chih-Yen; Chen, Kun-Hui; Liu, Kai-Chun; Hsu, Steen Jun-Ping; Chan, Chia-Tai

    2017-01-01

    Total knee arthroplasty (TKA) is the most common treatment for degenerative osteoarthritis of that articulation. However, either in rehabilitation clinics or in hospital wards, the knee range of motion (ROM) can currently only be assessed using a goniometer. In order to provide continuous and objective measurements of knee ROM, we propose the use of wearable inertial sensors to record the knee ROM during the recovery progress. Digitalized and objective data can assist the surgeons to control the recovery status and flexibly adjust rehabilitation programs during the early acute inpatient stage. The more knee flexion ROM regained during the early inpatient period, the better the long-term knee recovery will be and the sooner early discharge can be achieved. The results of this work show that the proposed wearable sensor approach can provide an alternative for continuous monitoring and objective assessment of knee ROM recovery progress for TKA patients compared to the traditional goniometer measurements. PMID:28241434

  11. Non-Traumatic Anterior Dislocation of a Total Knee Replacement Associated with Neurovascular Injury

    PubMed Central

    Aderinto, Joseph; Gross, Allan E; Rittenhouse, Bryan

    2009-01-01

    Prosthetic total knee replacements rarely dislocate. When dislocation does occur, it is usually in a posterior direction in association with a posterior stabilised, cruciate-sacrificing prosthesis. Neurovascular injury is unusual. In this report, we describe a case of anterior dislocation of a cruciate-retaining total knee replacement in a 67-year-old woman. The dislocation occurred in the absence of overt trauma and resulted in severe neurovascular injury. PMID:19686618

  12. The AAHKS Clinical Research Award: What Are the Costs of Knee Osteoarthritis in the Year Prior to Total Knee Arthroplasty?

    PubMed

    Bedard, Nicholas A; Dowdle, Spencer B; Anthony, Christopher A; DeMik, David E; McHugh, Michael A; Bozic, Kevin J; Callaghan, John J

    2017-09-01

    Despite American Academy of Orthopaedic Surgeons Clinical Practice Guidelines (CPGs) related to the non-arthroplasty management of osteoarthritis (OA) of the knee, non-recommended treatments remain in common use. We sought to determine the costs associated with non-arthroplasty management of knee OA in the year prior to total knee arthroplasty (TKA) and stratify them by CPG recommendation status. The Humana database was reviewed from 2007 to 2015 for primary TKA patients. Costs for hyaluronic acid (HA) and corticosteroid injections, physical therapy, braces, wedge insoles, opioids, non-steroidal anti-inflammatories, and tramadol in the year prior to TKA were calculated. Cost was defined as reimbursement paid by the insurance provider. Costs were analyzed relative to the overall non-inpatient costs for knee OA and categorized based on CPG recommendations. In total 86,081 primary TKA patients were analyzed and 65.8% had at least one treatment in the year prior to TKA. Treatments analyzed made up 57.6% of the total non-inpatient cost of knee OA in the year prior to TKA. Only 3 of the 8 treatments studied have a strong recommendation for their use (physical therapy, non-steroidal anti-inflammatories, tramadol) and costs for these interventions represented 12.2% of non-inpatient knee OA cost. In contrast, 29.3% of the costs are due to HA injections alone, which are not supported by CPGs. In the year prior to TKA, over half of the non-inpatient costs associated with knee OA are from injections, therapy, prosthetics, and prescriptions. Approximately 30% of this is due to HA injections alone. If only interventions recommend by the CPG are utilized then costs associated with knee OA could be decreased by 45%. Copyright © 2017 Elsevier Inc. All rights reserved.

  13. EFFECTS OF MOVEABLE PLATFORM TRAINING IN PREVENTING SLIP-INDUCED FALLS IN OLDER ADULTS

    PubMed Central

    Parijat, Prakriti; Lockhart, Thurmon E

    2011-01-01

    Identifying effective interventions is vitalin preventing slip-induced fall accidents in older adults. The purpose of the current study was to evaluate the efficacy of moveable platform training in improving recovery reactions and reducing fall frequency in older adults. Twenty-four older adults were recruited and randomly assigned to two groups (training and control). Both groups underwent three sessions including baseline slip, training, and transfer of training on a slippery surface. Both groups experienced two slips on a slippery surface, one during the baseline and the other (after two weeks) during the transfer of training session. In the training session, the training group underwent twelve simulated slips using a moveable platform while the control group performed normal walking trials. Kinematic, kinetic, and EMG data were collected during all the sessions. Results indicated a reduced incidence of falls in the training group during the transfer of training trial as compared to the control group. The training group was able to transfer proactive and reactive control strategies learned during training to the second slip trial. The proactive adjustments include increased center-of-mass velocity and transitional acceleration after training. Reactive adjustments include reduction in muscle onset and time to peak activations of knee flexors and ankle plantarflexors, reduced ankle and knee coactivation, reduced slip displacement, and reduced time to peak knee flexion, trunk flexion, and hip flexion velocities. In general, the results indicated a beneficial effect of perturbation training in reducing slip severity and recovery kinematics in healthy older adults. PMID:22134467

  14. Bicruciate retaining

    PubMed Central

    2016-01-01

    Total knee replacement (TKR) is a procedure used to treat knee arthropathy. Patients’ dissatisfaction is still relevant (literature reports dissatisfaction rates as high as 40%). The anterior cruciate ligament is usually removed while performing a total knee arthroplasty, thus changing knee biomechanics. As patients’ mean age to surgery is decreasing, bicruciate retaining models, which preserve normal biomechanics, may be useful in increasing patients’ outcomes. Limited data concerning bicruciate retaining arthroplasty is available; although clinical results are encouraging, there are concerns regarding surgical exposure, anterior cruciate integrity evaluation, and implant fixation. PMID:27162778

  15. International comparative evaluation of fixed-bearing non-posterior-stabilized and posterior-stabilized total knee replacements.

    PubMed

    Comfort, Thomas; Baste, Valborg; Froufe, Miquel Angel; Namba, Robert; Bordini, Barbara; Robertsson, Otto; Cafri, Guy; Paxton, Elizabeth; Sedrakyan, Art; Graves, Stephen

    2014-12-17

    Differences in survivorship of non-posterior-stabilized compared with posterior-stabilized knee designs carry substantial economic consequences, especially with limited health-care resources. However, these comparisons have often been made between relatively small groups of patients, often with short-term follow-up, with only small differences demonstrated between the groups. The goal of this study is to compare the outcomes of non-posterior-stabilized and posterior-stabilized total knee arthroplasties with use of a unique collaboration of multiple established knee arthroplasty registries. A distributed health data network was developed by the International Consortium of Orthopaedic Registries and was used in this study to reduce barriers to participation (such as security, propriety, legal, and privacy issues) compared with a centralized data warehouse approach. The study included only replacements in osteoarthritis patients who underwent total knee procedures involving fixed-bearing devices from 2001 to 2010. The outcome of interest was time to first revision. On average, not resurfacing showed a more harmful effect than resurfacing did when posterior-stabilized and non-posterior-stabilized knee replacements were compared, while the risk of revision for posterior-stabilized compared with non-posterior-stabilized knees was highest in year zero to one, followed by year one to two, years eight through ten, and years two through eight. Posterior-stabilized knees did significantly worse than non-posterior-stabilized knees did when the patella was not resurfaced. This difference was most pronounced in the first two years (year zero to one: hazard ratio [HR] = 2.15, 95% confidence interval [CI] = 1.56 to 2.95, p < 0.001; year one to two: HR = 1.61, 95% CI = 1.48 to 1.75, p < 0.001). When the patella was resurfaced, posterior-stabilized knees did significantly worse than non-posterior-stabilized knees did. This was again most pronounced in the first two years (year zero to one: HR = 1.75, 95% CI = 1.27 to 2.42, p = 0.001; year one to two: HR = 1.31, 95% CI = 1.19 to 1.45, p < 0.001). There was a reduced risk of revision with a patient age of more than sixty-five years (HR = 0.57, 95% CI = 0.55 to 0.60, p < 0.001). We found that fixed non-posterior-stabilized total knee arthroplasty performed better with or without patellar resurfacing than did fixed posterior-stabilized total knee arthroplasty. This effect was most pronounced in the first two years. The risk of revision for posterior-stabilized total knee arthroplasties was reduced with patellar resurfacing. Also, a patient age of more than sixty-five years and female gender reduced the risk of revision. Copyright © 2014 by The Journal of Bone and Joint Surgery, Incorporated.

  16. Interventions for the prediction and management of chronic postsurgical pain after total knee replacement: systematic review of randomised controlled trials.

    PubMed

    Beswick, Andrew D; Wylde, Vikki; Gooberman-Hill, Rachael

    2015-05-12

    Total knee replacement can be a successful operation for pain relief. However, 10-34% of patients experience chronic postsurgical pain. Our aim was to synthesise evidence on the effectiveness of applying predictive models to guide preventive treatment, and for interventions in the management of chronic pain after total knee replacement. We conducted a systematic review of randomised controlled trials using appropriate search strategies in the Cochrane Library, MEDLINE and EMBASE from inception to October 2014. No language restrictions were applied. Adult patients receiving total knee replacement. Predictive models to guide treatment for prevention of chronic pain. Interventions for management of chronic pain. Reporting of specific outcomes was not an eligibility criterion but we sought outcomes relating to pain severity. No studies evaluated the effectiveness of predictive models in guiding treatment and improving outcomes after total knee replacement. One study evaluated an intervention for the management of chronic pain. The trial evaluated the use of a botulinum toxin A injection with antinociceptive and anticholinergic activity in 49 patients with chronic postsurgical pain after knee replacement. A single injection provided meaningful pain relief for about 40 days and the authors acknowledged the need for a large trial with repeated injections. No trials of multidisciplinary interventions or individualised treatments were identified. Our systematic review highlights a lack of evidence about the effectiveness of prediction and management strategies for chronic postsurgical pain after total knee replacement. As a large number of people are affected by chronic pain after total knee replacement, development of an evidence base about care for these patients should be a research priority. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  17. Is latero-medial patellar mobility related to the range of motion of the knee joint after total knee arthroplasty?

    PubMed

    Ota, Susumu; Nakashima, Takeshi; Morisaka, Ayako; Omachi, Takaaki; Ida, Kunio; Kawamura, Morio

    2010-12-01

    Diminished range of motion (ROM) of the knee joint after total knee arthroplasty (TKA) is thought to be related to reduced patellar mobility. This has not been confirmed clinically due to a lack of quantitative methods adequate for measuring patellar mobility. We investigated the relationship between patellar mobility by a reported quantitative method and knee joint ROM after TKA. Forty-nine patients [osteoarthritis--OA: 29 knees; rheumatoid arthritis--RA: 20 knees] were examined after TKA. Respective medial and lateral patellar mobility was measured 1 and 6 months postoperatively using a patellofemoral arthrometer (PFA). Knee joint ROM was also measured in each of those 2 sessions. Although the flexion and extension of the knee joints improved significantly from 1 to 6 months after TKA, the medial and lateral patellar displacements (LPDs) failed to improve during that same period. Moreover, only the changes in knee flexion and medial patellar displacement (MPD) between the two sessions were positively correlated (r = 0.31, p < 0.05). However, our findings demonstrated that medial and lateral patellar mobility had no sufficient longitudinal relationship with knee ROM after TKA. Copyright © 2010 Elsevier Ltd. All rights reserved.

  18. Designing an E-Learning Platform for Postoperative Arthroplasty Adverse Events.

    PubMed

    Krumsvik, Ole Andreas; Babic, Ankica

    2017-01-01

    This paper presents a mobile software application development for e-learning based on the adverse events data within the field of arthroplasty. The application aims at providing a learning platform for physicians, patients, and medical students. Design of user interface aims to meet requirements of several user groups concerned with the adverse events of the knee and hip implants. Besides the clinical patient data, the platform wants to include even electronic patient data as a result of self-monitoring. Two different modules were created, one for medical staff and one for patients, both divided into the knee and hip areas. Knowledge is represented in forms of statistics, treatment options, and detailed, actual adverse event reports. Patients are given a choice of recommendation for two main situations: 'about your diagnosis', and 'what if you get a problem' as advice and guidance during the postoperative rehabilitation. Expert evaluation resulted in acceptance of the concept and provided feedback ideas. The patient evaluation has also been positive. Implementation will mean that a high-fidelity prototype will be developed and tested in larger user groups (medical staff, patients).

  19. Influence of bi- and tri-compartmental knee arthroplasty on the kinematics of the knee joint.

    PubMed

    Wünschel, Markus; Lo, Jiahsuan; Dilger, Torsten; Wülker, Nikolaus; Müller, Otto

    2011-01-27

    The cruciate ligaments are important stabilizers of the knee joint and determine joint kinematics in the natural knee and after cruciate retaining arthroplasty.No in vitro data is available to biomechanically evaluate the ability of the anterior cruciate ligament (ACL) to maintain knee joint kinematics after bicruciate-retaining bi-compartmental knee arthroplasty (BKA).Therefore, the objective of the current study was to investigate the kinematics of the natural knee joint, before and after installing bicruciate-retaining BKA and posterior cruciate retaining total knee arthroplasty. Specifically, we incorporated a dynamic knee simulator to simulate weight-bearing flexions on cadaveric knee specimen before and after surgical manipulations. In this cadaveric study we investigated rotational and translational tibiofemoral kinematics during simulated weight-bearing flexions of the intact knee, after bi-compartmental knee arthroplasty (BKA+), after resecting the ACL in BKA (BKA-), and after posterior cruciate retaining total knee arthroplasty (TKA). Rotation of BKA+ is closest to the intact knee joint, whereas TKA shows significant differences from 30 to 90 degree of flexion. Within the tested flexion range (15 to 90 degree of flexion), there was no significant difference in the anterior-posterior translation among intact, BKA+, and TKA knees. Resecting the ACL in BKA leads to a significant anterior tibial translation. BKA with intact cruciate ligaments resembles rotation and translation of the natural knee during a simulated weight-bearing flexion. It is a suitable treatment option for medial and patellofemoral osteoarthritis with advantages in rotational characteristics compared to TKA.

  20. Wear Distribution Detection of Knee Joint Prostheses by Means of 3D Optical Scanners

    PubMed Central

    Affatato, Saverio; Valigi, Maria Cristina; Logozzo, Silvia

    2017-01-01

    The objective of this study was to examine total knee polyethylene inserts from in vitro simulation to evaluate and display—using a 3D optical scanner—wear patterns and wear rates of inserts exposed to wear by means of simulators. Various sets of tibial inserts have been reconstructed by using optical scanners. With this in mind, the wear behavior of fixed and mobile bearing polyethylene knee configurations was investigated using a knee wear joint simulator. After the completion of the wear test, the polyethylene menisci were analyzed by an innovative 3D optical scanners in order to evaluate the 3D wear distribution on the prosthesis surface. This study implemented a new procedure for evaluating polyethylene bearings of joint prostheses obtained after in vitro wear tests and the proposed new approach allowed quantification of the contact zone on the geometry of total knee prostheses. The results of the present study showed that mobile TKPs (total knee prosthesis) have lower wear resistance with respect to fixed TKPs. PMID:28772725

  1. Cross-linked polyethylene does not reduce wear in total knee arthroplasty.

    PubMed

    Lasurt-Bachs, S; Torner, P; Maculé, F; Prats, E; Menéndez-García, F; Ríos-Guillermo, J; Torrents, A

    To compare two different types of inserts: Ultra-high molecular weight polyethylene (UHMWPE) and cross-linked polyethylene with a quantitative and qualitative study of polyethylene wear particles in synovial fluid 3 years after total knee arthroplasty. A prospective, randomized, controlled cohort study with blinded evaluation was carried out on 25 patients undergoing staged bilateral total knee replacement, 6 months apart. Knee arthrocentesis was performed on 12 patients 3 years after surgery, and the polyethylene particles were analyzed. No significant differences were found in the number of particles generated by the two different types of inserts at 3 years from total knee arthroplasty (3,000×: x¯ cross-linked=849.7; x¯ UHMWPE=796.9; P=.63; 20,000×: x¯ cross-linked=66.3; x¯ UHMWPE=73.1; P=.76). Likewise, no differences in the probability of finding elongated (χ 2 =0.19; P=.66) or rounded (χ 2 =1.44; P=.23) particles in both types of inserts were observed. However, the probability of finding fibrillar particles is 3.08 times greater in UHMWPE. Cross-linked polyethylene does not significantly reduce the generation of polyethylene particles in patients with total knee arthroplasty, 3 years after the surgical procedure. Copyright © 2018 SECOT. Publicado por Elsevier España, S.L.U. All rights reserved.

  2. Simultaneous bilateral total knee and ankle arthroplasty as a single surgical procedure.

    PubMed

    Pagenstert, Geert; Hintermann, Beat

    2011-10-13

    Simultaneous osteoarthritis (OA) of the ankle joint complicates primary total knee arthroplasty (TKA). In such cases, rehabilitation of TKA is limited by debilitating ankle pain, but varus or valgus ankle arthritis may even compromise placement of knee prosthetic components. We present a patient with simultaneous bilateral valgus and patellofemoral OA of the knees and bilateral varus OA of the ankle joints that equally contributed to overall disability. This 63 years old, motivated and otherwise healthy patient was treated by simultaneous bilateral total knee and ankle arthroplasty (quadruple total joint arthroplasty, TJA) during the same anesthesia. Two years outcome showed excellent alignment and function of all four replaced joints. Postoperative time for rehabilitation, back to work (6th week) and hospital stay (12 days) of this special patient was markedly reduced compared to the usual course of separate TJA. Simultaneous quadruple TJA in equally disabling OA of bilateral deformed knees and ankles resulted in a better functional outcome and faster recovery compared to the average reported results after TKA and TAA in literature. However, careful preoperative planning, extensive patient education, and two complete surgical teams were considered essential for successful performance. To the best of our knowledge this is the first case report in literature about quadruple major total joint arthroplasty implanted during the same anesthesia in the same patient.

  3. Comparative study of design and PCL-substituting systems of total knee prosthesis.

    PubMed

    Adam, R; Orban, C; Orban, H

    2014-01-01

    The aim of this study is to assess postoperative results obtained by different knee implants. The main implant types differences are given by generally implant design and by PCL substituting systems that are used. Between 04.2004 - 02.2012 we have performed 506 total knee arthroplasties (TKA), on a group of 460 patients. Our choice, was for cemented total knee prostheses, using PCL-substituting systems. Regarding general design and PCL-substituting systems of the implant we had divided the main group in three lots. In order to assess post operative result we had used the American Knee Society Score(AKSS). All prostheses types that we had implanted, had registered satisfactory values of AKSS. Our study showed that one group scored higher values of AKSS, compared the other two, but there are not statistical semnificative differences (p=0,09). Celsius.

  4. Single-use instruments, cutting blocks, and trials increase efficiency in the operating room during total knee arthroplasty: a prospective comparison of navigated and non-navigated cases.

    PubMed

    Mont, Michael A; McElroy, Mark J; Johnson, Aaron J; Pivec, Robert

    2013-08-01

    The purpose of this prospective controlled trial was to determine if efficiency increases could be achieved in non-navigated and navigated total knee arthroplasties by replacing traditional saws, cutting blocks, and trials with specialized saws and single-use cutting blocks and trials. Various timing metrics during total knee arthroplasty, including operating room preparation times and specific intra-operative times, were measured in 400 procedures performed by eight different surgeons at 6 institutions. Efficiency increases were the result of statistically significant reductions in combined instrument setup and cleanup times as well as in adjusted surgical episode times in navigated total knee arthroplasties. Single-use instruments show promising benefits, but adequate patient follow-up is needed to confirm safety and efficacy before they can be widely adopted. Nevertheless, the authors believe that the use of single-use instruments, cutting guides, and trial implants for total knee arthroplasty will play an increasing role in improving operating room efficiency. Copyright © 2013 Elsevier Inc. All rights reserved.

  5. A prospective randomised study comparing the jubilee dressing method to a standard adhesive dressing for total hip and knee replacements.

    PubMed

    Burke, Neil G; Green, Connor; McHugh, Gavin; McGolderick, Niall; Kilcoyne, Carol; Kenny, Patrick

    2012-08-01

    It is important to reduce potential wound complications in total hip and total knee arthroplasty procedures. The purpose of this study was to compare the jubilee dressing method to a standard adhesive dressing. 124 patients (62 total hip replacements and 62 total knee replacements) were randomly selected to have either a standard adhesive dressing or jubilee method dressing. The number of dressing changes, incidence of blistering, leakage, appearance of inflammation, infection rate and the average stay in hospital was recorded for each patient. The jubilee dressing significantly reduced the rate of blistering, leakage and number of dressing changes when compare to a traditional adhesive dressing (p < 0.05). The rate of inflammation and average length of stay in hospital was not significantly different between the two groups. The authors recommend the use of this dressing for total hip and total knee arthroplasty procedures due to the associated lower complication rate. Copyright © 2012 Tissue Viability Society. Published by Elsevier Ltd. All rights reserved.

  6. Results of revision total knee arthroplasty using press-fit cementless stem.

    PubMed

    Iamaguchi, Maurício Masasi; de Castro, Fernando Bley Vicente; Gobbi, Riccardo Gomes; Tirico, Luis Eduardo Passarelli; Pécora, José Ricardo; Camanho, Gilberto Luis

    2013-01-01

    To show our experience with press-fit cementless stem and metaphyseal fixation with cement in a selected series of patients who underwent revision total knee arthroplasty. Thirty-four patients (35 knees) underwent revision total knee arthroplasty using the press-fit technique. Minimum follow-up was one year (mean 2.2 years) with a maximum length of three years. Of 34 patients, 20 were women and 14 were men. There was one death due to causes not related to arthroplasty and one patient dropout. There were no cases in which further review was necessary. Patients who underwent revision had clinical and functional improvement demonstrated by the results of the KSS, results of the SF-36 quality of life questionnaire, through gains in range of motion and improved limb alignment. There was postoperative clinical and functional improvement in comparison to the preoperative status in revision total knee arthroplasty with press-fit cementless stem. Level of Evidence IV, Case series.

  7. Knee Extensor Strength and Gait Characteristics After Minimally Invasive Unicondylar Knee Arthroplasty vs Minimally Invasive Total Knee Arthroplasty: A Nonrandomized Controlled Trial.

    PubMed

    Braito, Matthias; Giesinger, Johannes M; Fischler, Stefan; Koller, Arnold; Niederseer, David; Liebensteiner, Michael C

    2016-08-01

    In light of the existing lack of evidence, it was the aim of this study to compare gait characteristics and knee extensor strength after medial unicondylar knee arthroplasty (MUKA) with those after total knee arthroplasty (TKA), given the same standardized minimally invasive surgery (MIS) approach in both groups. Patients scheduled for MIS-MUKA or MIS-TKA as part of clinical routine were invited to participate. A posterior cruciate ligament-retaining total knee design was used for all MIS-TKA. A 3-dimensional gait analysis was performed preoperatively with a VICON system and at 8 weeks postoperative to determine temporospatial parameters, ground reaction forces, joint angles, and joint moments. At the same 2 times, isokinetic tests were performed to obtain peak values of knee extensor torque. A multivariate analysis of variance was conducted and included the main effects time (before and after surgery) and surgical group and the group-by-time interaction effect. Fifteen MIS-MUKA patients and 17 MIS-TKA patients were eligible for the final analysis. The groups showed no differences regarding age, body mass index, sex, side treated, or stage of osteoarthritis. We determined neither intergroup differences nor time × group interactions for peak knee extensor torque or any gait parameters (temporospatial, ground reaction forces, joint angles, and joint moments). It is concluded that MUKA is not superior to TKA with regard to knee extensor strength or 3-dimensional gait characteristics at 8 weeks after operation. As gait characteristics and knee extensor strength are only 2 of the various potential outcome parameters (knee scores, activity scores…) and quadriceps strength might take a longer time to recover, our findings should be interpreted with caution. Copyright © 2016 The Authors. Published by Elsevier Inc. All rights reserved.

  8. Technique for Periarticular Local Infiltrative Anesthesia Delivery Using Liposomal Bupivacaine in Total Knee Arthroplasty.

    PubMed

    Connelly, Jacob O; Edwards, Paul K; Mears, Simon C; Barnes, C Lowry

    2015-01-01

    Postoperative pain control after total knee arthroplasty is a major contributing factor to patient satisfaction, rehabilitation, and length of stay. Current clinical practice guidelines recommend a multimodal pain management protocol, including the use of regional anesthesia. Periarticular injection (PAI) has been shown to provide excellent pain relief after total knee arthroplasty. Recently, liposomal bupivacaine has been introduced as a long-acting alternative to traditional local anesthetics, such as bupivacaine or ropivacaine. Liposomal bupivacaine is a sustained-release preparation designed to provide local analgesia up to 72 hours after initial application. The efficacy of PAI relies significantly on a meticulous, systematic injection technique. This article details recommendations for solution preparation and injection during total knee arthroplasty on the basis of the experience of a high-volume orthopaedic reconstruction service.

  9. Multimodal analgesia without parenteral narcotics for total knee arthroplasty.

    PubMed

    Dorr, Lawrence D; Raya, Julio; Long, William T; Boutary, Myriam; Sirianni, Leigh Ellen

    2008-06-01

    Use of parenteral narcotics after total knee arthroplasty is considered by most orthopedic surgeons to be the standard of care. This study tested the hypothesis that a multimodal oral pain medication protocol could control pain and minimize complications of parenteral narcotics. Postoperative oral analgesia was augmented with either continuous epidural infusion or continuous femoral infusion using ropivacaine only. Seventy patients had total knee arthroplasty with a protocol that included preemptive oral analgesics, epidural anesthesia, pericapsular analgesic injection, and postoperative analgesia without parenteral opioids. The average daily pain score was less than 4 out of 10, nausea occurred in 15 patients (21%), emesis in 1 patient (1.4%), and there were no severe complications. This study proved the hypothesis that pain after total knee arthroplasty could be effectively managed without routine use of parenteral opioids.

  10. Acute Perioperative Comparison of Patient-Specific Instrumentation versus Conventional Instrumentation Utilization during Bilateral Total Knee Arthroplasty.

    PubMed

    Steimle, Jerrod A; Groover, Michael T; Webb, Brad A; Ceccarelli, Brian J

    2018-01-01

    Utilizing patient-specific instrumentation during total knee arthroplasty has gained popularity in recent years with theoretical advantages in blood loss, intraoperative time, length of stay, postoperative alignment, and functional outcome, amongst others. No study has compared acute perioperative measures between patient-specific instrumentation and conventional instrumentation in the bilateral total knee arthroplasty setting. We compared patient-specific instrumentation versus conventional instrumentation in the setting of bilateral total knee arthroplasty to determine any benefits in the immediate perioperative period including surgical time, blood loss, pain medication use, length of stay, and discharge disposition. A total of 49 patients with standard instrumentation and 31 patients with patient-specific instrumentation were retrospectively reviewed in a two-year period at one facility. At baseline, the groups were comparable with respect to age, ASA, BMI, and comorbid conditions. We analyzed data on operative time, blood loss, hemoglobin change, need for transfusion, pain medication use, length of stay, and discharge disposition. There was no statistically significant difference between groups in regards to these parameters. Patient-specific instrumentation in the setting of bilateral total knee arthroplasty did not provide any immediate perioperative benefit compared to conventional instrumentation.

  11. [Local infiltration analgesia in total joint replacement].

    PubMed

    de Jonge, Tamás; Görgényi, Szabolcs; Szabó, Gabriella; Torkos, Miklós Bulcsú

    2017-03-01

    Total hip and knee replacment surgeries are characterized by severe postoperative pain. Local infiltration analgesia is proved to be very effective. However this method has not been widely used in Hungary. To evaluate the efficacy of the local infiltration analgesia with modified components in patients underwent total hip or knee replacement surgery. Data of 99 consecutive patients underwent primary total hip or knee replacement surgery were evaluated prospectively. In all the 99 surgeries modified local infiltration analgesia was applied. Postoperative pain reported on a visual analog scale was recorded as well as the need for further analgetics during the first 18 hours after surgery. The cost of the analgetic drugs was calculated. The control group comprised 97 consecutive patients underwent total hip or knee replacement, where local infiltration analgesia was not applied. Statistical analysis was done. Patients received local infiltration analgesia reported significantly less pain (p<0.001). The need for postoperatively given analgetics was almost 50% less, and the cost of all postoperative analgetics was 47% less than in the control group. In total hip and knee replacement surgeries the modified local infiltration analgesia decreases postoperative pain effectively and contribute to the early mobilization of the patients. Orv. Hetil., 2017, 158(9), 352-357.

  12. Knee Joint Kinetics in Relation to Commonly Prescribed Squat Loads and Depths

    PubMed Central

    Cotter, Joshua A.; Chaudhari, Ait M.; Jamison, Steve T.; Devor, Steven T.

    2014-01-01

    Controversy exists regarding the safety and performance benefits of performing the squat exercise to depths beyond 90° of knee flexion. Our aim was to compare the net peak external knee flexion moments (pEKFM) experienced over typical ranges of squat loads and depths. Sixteen recreationally trained males (n = 16; 22.7 ± 1.1 yrs; 85.4 ± 2.1 kg; 177.6 ± 0.96 cm; mean ± SEM) with no previous lower limb surgeries or other orthopedic issues and at least one year of consistent resistance training experience while utilizing the squat exercise performed single repetition squat trials in a random order at squat depths of above parallel, parallel, and below parallel. Less than one week before testing, one repetition maximum (1RM) values were found for each squat depth. Subsequent testing required subjects to perform squats at the three depths with three different loads: unloaded, 50% 1RM, and 85% 1RM (nine total trials). Force platform and kinematic data were collected to calculate pEKFM. To assess differences among loads and depths, a two-factor (load and depth) repeated-measures ANOVA with significance set at the P < 0.05 level was used. Squat 1RM significantly decreased 13.6% from the above parallel to parallel squat and another 3.6% from the parallel to the below parallel squat (P < 0.05). Net peak external knee flexion moments significantly increased as both squat depth and load were increased (P ≤ 0.02). Slopes of pEKFM were greater from unloaded to 50% 1RM than when progressing from 50% to 85% 1RM (P < 0.001). The results suggest that that typical decreases in squat loads used with increasing depths are not enough to offset increases in pEKFM. PMID:23085977

  13. Knee joint biomechanics and neuromuscular control during gait before and after total knee arthroplasty are sex-specific.

    PubMed

    Astephen Wilson, Janie L; Dunbar, Michael J; Hubley-Kozey, Cheryl L

    2015-01-01

    The future of total knee arthroplasty (TKA) surgery will involve planning that incorporates more patient-specific characteristics. Despite known biological, morphological, and functional differences between men and women, there has been little investigation into knee joint biomechanical and neuromuscular differences between men and women with osteoarthritis, and none that have examined sex-specific biomechanical and neuromuscular responses to TKA surgery. The objective of this study was to examine sex-associated differences in knee kinematics, kinetics and neuromuscular patterns during gait before and after TKA. Fifty-two patients with end-stage knee OA (28 women, 24 men) underwent gait and neuromuscular analysis within the week prior to and one year after surgery. A number of sex-specific differences were identified which suggest a different manifestation of end-stage knee OA between the sexes. Copyright © 2014 Elsevier Inc. All rights reserved.

  14. Infected total knee arthroplasty treated with arthrodesis using a modular nail.

    PubMed

    Waldman, B J; Mont, M A; Payman, K R; Freiberg, A A; Windsor, R E; Sculco, T P; Hungerford, D S

    1999-10-01

    Failed treatment of infected total knee replacement presents few attractive surgical options. Knee arthrodesis is challenging surgically and can be complicated by nonunion, malunion, or recurrent infection. Recently, a modular titanium intramedullary nail has been used in an attempt to reduce the incidence of nonunion and the rate of complications. In the present study, a review of the results of knee arthrodesis after infected total knee arthroplasty in 21 patients at three large academic institutions was performed. All patients were followed up for a mean of 2.4 years (range, 2-7.5 years). The mean age of the patients was 64 years. The mean number of previous operations was four (range, 2-9 operations). A solid arthrodesis was achieved without additional surgical treatment in 20 of 21 patients (95%). The mean time to fusion was 6.3 months. The one patient who suffered a nonunion achieved fusion after a subsequent bone grafting procedure. Based on the present study, intramedullary arthrodesis with a coupled titanium nail, is a reliable, effective method of achieving fusion after infection of a total knee arthroplasty. This procedure resulted in a high rate of fusion and a lower rate of complications when compared with traditional methods of arthrodesis.

  15. The Cruciate Ligaments in Total Knee Arthroplasty.

    PubMed

    Parcells, Bertrand W; Tria, Alfred J

    2016-01-01

    The early knee replacements were hinge designs that ignored the ligaments of the knee and resurfaced the joint, allowing freedom of motion in a single plane. Advances in implant fixation paved the way for modern designs, including the posterior-stabilized (PS) total knee arthroplasty (TKA) that sacrifices both cruciate ligaments while substituting for the posterior cruciate ligament (PCL), and the cruciate-retaining (CR) TKA designs that sacrifice the anterior cruciate ligament but retain the PCL. The early bicruciate retaining (BCR) TKA designs suffered from loosening and early failures. Townley and Cartier designed BCR knees that had better clinical results but the surgical techniques were challenging.Kinematic studies suggest that normal motion relies on preservation of both cruciate ligaments. Unicompartmental knee arthroplasty retains all knee ligaments and closely matches normal motion, while PS and CR TKA deviate further from normal. The 15% to 20% dissatisfaction rate with current TKA has renewed interest in the BCR design. Replication of normal knee kinematics and proprioception may address some of the dissatisfaction.

  16. Bridging knee arthrodesis for limb salvage using an intramedullary cemented nail: a retrospective outcome analysis of a case series.

    PubMed

    Neuerburg, Carl; Bieger, Ralf; Jung, Sebastian; Kappe, Thomas; Reichel, Heiko; Decking, Ralf

    2012-08-01

    Failed total knee replacement with compromised bone and soft-tissues can be challenging. In these situations, arthrodesis remains a treatment option of a limb-saving procedure. We investigated the outcome of treatment with an intramedullary cemented knee arthrodesis nail implanted in 22 consecutive patients with forlorn situations after failed total knee replacement. There were three major complications due to re-infection and two minor complications due to wound-healing disturbances that healed with the implant retained after an average follow-up of 3.4 years. Clinical examination, Short Form-36 and Oxford knee scores revealed low pain levels, safe implant anchorage, and improved stability of the knee, whilst autonomous mobility utilizing walking aids was still possible. Bridging knee arthrodesis with an intramedullary nail is a valuable salvage procedure with acceptable clinical results. As recurring infection remains the most challenging complication, regular clinical and radiological follow-up examinations are necessary following implant-related knee arthrodesis to allow timely intervention in case of loosening.

  17. Reverse Engineering Nature to Design Biomimetic Total Knee Implants.

    PubMed

    Varadarajan, Kartik Mangudi; Zumbrunn, Thomas; Rubash, Harry E; Malchau, Henrik; Muratoglu, Orhun K; Li, Guoan

    2015-10-01

    While contemporary total knee arthroplasty (TKA) provides tremendous clinical benefits, the normal feel and function of the knee is not fully restored. To address this, a novel design process was developed to reverse engineer "biomimetic" articular surfaces that are compatible with normal soft-tissue envelope and kinematics of the knee. The biomimetic articular surface is created by moving the TKA femoral component along in vivo kinematics of normal knees and carving out the tibial articular surface from a rectangular tibial block. Here, we describe the biomimetic design process. In addition, we utilize geometric comparisons and kinematic simulations to show that; (1) tibial articular surfaces of conventional implants are fundamentally incompatible with normal knee motion, and (2) the anatomic geometry of the biomimetic surface contributes directly to restoration of normal knee kinematics. Such biomimetic implants may enable us to achieve the long sought after goal of a "normal" knee post-TKA surgery. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  18. Closed Incision Negative Pressure Therapy Versus Standard of Care Surgical Dressing in Revision Total Knee Arthroplasty

    ClinicalTrials.gov

    2018-06-07

    Surgical Wound; Revision Total Knee Arthroplasty; Wounds and Injuries; Joint Disease; Musculoskeletal Disease; Prosthesis-Related Infections; Infection; Postoperative Complications; Pathologic Processes

  19. Cost-benefit comparison of the Oxford Knee score and the American Knee Society score in measuring outcome of total knee arthroplasty.

    PubMed

    Medalla, Greg Anthony; Moonot, Pradeep; Peel, Tamlyn; Kalairajah, Yegappan; Field, Richard E

    2009-06-01

    The American Knee Society score (AKSS) and the Oxford Knee score (OKS) are validated outcome measures for evaluation of total knee arthroplasties (TKAs). We investigated whether patient self-assessment using the OKS offers a viable alternative to clinical review using the AKSS. Preoperative, 2-year, 5-year, and 10-year postoperative OKS and AKSS were reviewed from TKA patients. The scores were analyzed using the Pearson correlation. There was good correlation of OKS and AKSS at 2 years. This implies that patient self-assessment is a viable screening tool to identify which patients require clinical review, at 2 years, after TKA. However, the moderate correlation at 5 and 10 years indicates that clinical evaluation remains necessary at these time points.

  20. Ground reaction forces and knee kinetics during single and repeated badminton lunges.

    PubMed

    Lam, Wing Kai; Ding, Rui; Qu, Yi

    2017-03-01

    Repeated movement (RM) lunge that frequently executed in badminton might be used for footwear evaluation. This study examined the influence of single movement (SM) and RM lunges on the ground reaction forces (GRFs) and knee kinetics during the braking phase of a badminton lunge step. Thirteen male university badminton players performed left-forward lunges in both SM and RM sessions. Force platform and motion capturing system were used to measure GRFs and knee kinetics variables. Paired t-test was performed to determine any significant differences between SM and RM lunges regarding mean and coefficient of variation (CV) in each variable. The kinetics results indicated that compared to SM lunges, the RM lunges had shorter contact time and generated smaller maximum loading rate of impact force, peak knee anterior-posterior force, and peak knee sagittal moment but generated larger peak horizontal resultant forces (Ps < 0.05). Additionally, the RM lunges had lower CV for peak knee medial-lateral and vertical forces (Ps < 0.05). These results suggested that the RM testing protocols had a distinct loading response and adaptation pattern during lunge and that the RM protocol showed higher within-trial reliability, which may be beneficial for the knee joint loading evaluation under different interventions.

  1. Effect of postoperative use of nasal oxygen catheter supplementation in wound healing following total knee arthroplasty

    PubMed Central

    Helito, Camilo Partezani; Junqueira, Jader Joel Machado; Gobbi, Ricardo Gomes; Angelini, Fábio Janson; Rezende, Marcia Uchoa; Tírico, Luis Eduardo Passarelli; Demange, Marco Kawamura; da Mota e Albuquerque, Roberto Freire; Pécora, José Ricardo; Camanho, Gilberto Luis

    2014-01-01

    OBJECTIVES: Healing is an event that is fundamental to the success of total knee arthroplasty. The aims of the present study were to compare the rates of complications related to wound healing between two groups of volunteers submitted to total knee arthroplasty and to evaluate the effects of postoperative oxygen supplementation by means of a nasal catheter. METHOD: A total of 109 patients who underwent total knee arthroplasty were randomized into two groups, namely, groups that did and did not receive postoperative oxygen supplementation via a nasal catheter. The surgical wound was monitored every day during the hospital stay and on the 7th, 14th, 21st, 30th and 42nd postoperative days. Characteristics related to healing were observed, including hyperemia, dehiscence, necrosis, phlyctenules and deep and superficial infection. RESULTS: There were no cases of deep infection. Hyperemia was statistically correlated with the total number of complications in the groups, with oxygen demonstrated to be a protective factor against hyperemia. Approximately 30% of the patients who exhibited hyperemia had other complications, independent of oxygen supplementation. CONCLUSION: Oxygen supplementation following total knee arthroplasty was shown to be effective in diminishing hyperemia around the operative wound. The development of hyperemia was a precursor to other complications, irrespective of whether oxygen supplementation was used. PMID:25518030

  2. Influence of Ligament Properties on Knee Mechanics in Walking

    PubMed Central

    Smith, Colin R.; Lenhart, Rachel L.; Kaiser, Jarred; Vignos, Mike; Thelen, Darryl G.

    2016-01-01

    Computational knee models provide a powerful platform to investigate the effects of injury and surgery on functional knee behavior. The objective of this study was to use a multibody knee model to investigate the influence of ligament properties on tibiofemoral kinematics and cartilage contact pressures in the stance phase of walking. The knee model included 14 ligament bundles and articular cartilage contact acting across the tibiofemoral and patellofemoral joints. The knee was incorporated into a lower extremity musculoskeletal model and used to simulate knee mechanics during the stance phase of normal walking. A Monte Carlo approach was employed to assess the influence ligament stiffness and reference strains on knee mechanics. The ACL, MCL and posterior capsule properties exhibited significant influence on anterior tibial translation at heel strike, with the ACL acting as the primary restraint to anterior translation in mid-stance. The MCL and LCL exhibited the greatest influence on tibial rotation from heel strike through mid-stance. Simulated tibial plateau contact location was dependent on the ACL, MCL and LCL properties, while pressure magnitudes were most dependent on the ACL. A decrease in ACL stiffness or reference strain significantly increased average contact pressure in mid-stance, with the pressure migrating posteriorly on the medial tibial plateau. These ligament-dependent shifts in tibiofemoral cartilage contact during walking are potentially relevant to consider when investigating the causes of early onset osteoarthritis following knee ligament injury and surgical treatment. PMID:26408997

  3. Perioperative comorbidities and complications among patients undergoing primary total knee arthroplasty: a retrospective analysis and prospective survey.

    PubMed

    Oviedo Baena, Ana M; Moeschler, Susan M; Smith, Hugh M; Duncan, Christopher M; Schroeder, Darrell R; Kopp, Sandra L

    2015-11-01

    To determine the demographic characteristics of patients undergoing primary total knee arthroplasty during the years 1989, 1999, and 2009 at our institution and determine whether their characteristics mirror the changing US demographic characteristics. Retrospective chart review of patients and prospective survey of experienced anesthesia providers in total knee arthroplasty. Tertiary care academic medical center. All patients 18 years and older who underwent unilateral primary total knee arthroplasty in 1989, 1999, and 2009 were identified through the Mayo Clinic Total Joint Registry. For each year, 200 patients were randomly selected. The demographic characteristics, comorbidities, perioperative care, and postoperative outcomes of patients, as well as survey responses from experienced anesthesia providers. During the 3 study years, a total of 591 patients were included for analysis. A statistically significant increase in body mass index (BMI) was observed over time in patients undergoing primary total knee arthroplasty (average BMI, 29.01 in 1989, 31.32 in 1999, and 32.32 in 2009 [P < .001]). Despite the increase in patient comorbidities, the percentage of patients who had postoperative complications decreased over time (P = .003), and postoperative disposition (general medicine ward vs intensive care unit) did not change. Our provider survey received a 76% response rate. In total, 82% of anesthesia providers who responded to the survey perceived that both BMI and the number of comorbidities had increased. Of survey respondents, 67% state that they have modified their perioperative anesthesia care because of changes in body habitus and patient comorbidities. The number of obese patients with comorbidities who present for total knee arthroplasty at our institution has increased over the past 20 years. Despite this fact, a reduction was detected in postoperative complications. Copyright © 2015 Elsevier Inc. All rights reserved.

  4. Longitudinal tear of the medial meniscus posterior horn in the anterior cruciate ligament-deficient knee significantly influences anterior stability.

    PubMed

    Ahn, Jin Hwan; Bae, Tae Soo; Kang, Ki-Ser; Kang, Soo Yong; Lee, Sang Hak

    2011-10-01

    Longitudinal tears of the medial meniscus posterior horn (MMPH) are commonly associated with a chronic anterior cruciate ligament (ACL) deficiency. Many studies have demonstrated the importance of the medial meniscus in terms of limiting the amount of anterior-posterior tibial translation in response to anterior tibial loads in ACL-deficient knees. An MMPH tear in an ACL-deficient knee increases the anterior-posterior tibial translation and rotatory instability. In addition, MMPH repair will restore the tibial translation to the level before the tear. Controlled laboratory study. Ten human cadaveric knees were tested sequentially using a custom testing system under 5 conditions: intact, ACL deficient, ACL deficient with an MMPH peripheral longitudinal tear, ACL deficient with an MMPH repair, and ACL deficient with a total medial meniscectomy. The knee kinematics were measured at 0°, 15°, 30°, 60°, and 90° of flexion in response to a 134-N anterior and 200-N axial compressive tibial load. The rotatory kinematics were also measured at 15° and 30° of flexion in a combined rotatory load of 5 N·m of internal tibial torque and 10 N·m of valgus torque. Medial meniscus posterior horn longitudinal tears in ACL-deficient knees resulted in a significant increase in anterior-posterior tibial translation at all flexion angles except 90° (P < .05). An MMPH repair in an ACL-deficient knee showed a significant decrease in anterior-posterior tibial translation at all flexion angles except 60° compared with the ACL-deficient/MMPH tear state (P < .05). The total anterior-posterior translation of the ACL-deficient/MMPH repaired knee was not significantly increased compared with the ACL (only)-deficient knee but was increased compared with the ACL-intact knee (P > .05). A total medial meniscectomy in an ACL-deficient knee did not increase the anterior-posterior tibial translation significantly compared with MMPH tears in ACL-deficient knees at all flexion angles (P > .05). In a combined rotatory load, tibial rotation after MMPH tears or a total medial meniscectomy in an ACL-deficient knee were not affected significantly at all flexion angles. This study shows that an MMPH longitudinal tear in an ACL-deficient knee alters the knee kinematics, particularly the anterior-posterior tibial translation. MMPH repair significantly improved anterior-posterior tibial translation in ACL-deficient knees. These findings may help improve the treatment of patients with ACL and MMPH longitudinal tear by suggesting that the medial meniscal repairs should be performed for greater longevity when combined with an ACL reconstruction.

  5. Total knee arthroplasty in motivated patients with knee osteoarthritis and athletic activity approach type goals: a conceptual decision-making model.

    PubMed

    Nyland, John; Kanouse, Zachary; Krupp, Ryan; Caborn, David; Jakob, Rolie

    2011-01-01

    Knee osteoarthritis is one of the most common disabling medical conditions. With longer life expectancy the number of total knee arthroplasty (TKA) procedures being performed worldwide is projected to increase dramatically. Patient education, physical activity, bodyweight levels, expectations and goals regarding the ability to continue athletic activity participation are also increasing. For the subset of motivated patients with knee osteoarthritis who have athletic activity approach type goals, early TKA may not be the best knee osteoarthritis treatment option to improve satisfaction, quality of life and outcomes. The purpose of this clinical commentary is to present a conceptual decision-making model designed to improve the knee osteoarthritis treatment intervention outcome for motivated patients with athletic activity approach type goals. The model focuses on improving knee surgeon, patient and rehabilitation clinician dialogue by rank ordering routine activities of daily living and quality of life evoking athletic activities based on knee symptom exacerbation or re-injury risk. This process should help establish realistic patient expectations and goals for a given knee osteoarthritis treatment intervention that will more likely improve self-efficacy, functional independence, satisfaction and outcomes while decreasing the failure risk associated with early TKA.

  6. Kinematic analysis of total knee prosthesis designed for Asian population.

    PubMed

    Low, F H; Khoo, L P; Chua, C K; Lo, N N

    2000-01-01

    In designing a total knee replacement (TKR) prosthesis catering for the Asian population, 62 sets of femur were harvested and analyzed. The morphometrical data obtained were found to be in good agreement with dimensions typical of the Asian knee and has reaffirmed the fact that Caucasian knees are generally larger than Asian knees. Subsequently, these data when treated using a multivariate statistical technique resulted in the establishment of major design parameters for six different sizes of femoral implants. An extra-small implant size with established dimensions and geometrical shape has surfaced from the study. The differences between the Asian knees and the Caucasian knees are discussed. Employing the established femoral dimensions and motion path of the knee joint, the articulating tibia profile was generated. All the sizes of implants were modeled using a computer-aided software package. Thereupon, these models that accurately fits the local Asian knee were transported into a dynamic and kinematic analysis software package. The tibiofemoral joint was modeled successfully as a slide curve joint to study intuitively the motion of the femur when articulating on the tibia surface. An optimal tibia profile could be synthesized to mimic the natural knee path motion. Details of the analysis are presented and discussed.

  7. Total knee replacement-cementless tibial fixation with screws: 10-year results.

    PubMed

    Ersan, Önder; Öztürk, Alper; Çatma, Mehmet Faruk; Ünlü, Serhan; Akdoğan, Mutlu; Ateş, Yalım

    2017-12-01

    The aim of this study was to evaluate the long term clinical and radiological results of cementless total knee replacement. A total of 51 knees of 49 patients (33 female and 16 male; mean age: 61.6 years (range, 29-66 years)) who underwent TKR surgery with a posterior stabilized hydroxyapatite coated knee implant were included in this study. All of the tibial components were fixed with screws. The HSS scores were examined preoperatively and at the final follow-up. Radiological assessment was performed with Knee Society evaluating and scoring system. Kaplan-Meier survival analysis was performed to rule out the survival of the tibial component. The mean HSS scores were 45.8 (range 38-60) and 88.1 (range 61-93), preoperatively and at the final follow-up respectively. Complete radiological assessment was performed for 48 knees. Lucent lines at the tibial component were observed in 4 patients; one of these patients underwent a revision surgery due to the loosening of the tibial component. The 10-year survival rate of a tibial component was 98%. Cementless total knee replacement has satisfactory long term clinical results. Primary fixation of the tibial component with screws provides adequate stability even in elderly patients with good bone quality. Level IV, Therapeutic study. Copyright © 2017 Turkish Association of Orthopaedics and Traumatology. Production and hosting by Elsevier B.V. All rights reserved.

  8. Timeframe for return to driving for patients with minimally invasive knee arthroplasty is associated with knee performance on functional tests

    PubMed Central

    2014-01-01

    Background This study hopes to establish the timeframe for a safe return to driving under different speed conditions for patients after minimally invasive total knee arthroplasty and further explores how well various kinds of functional tests on knee performance can predict the patients’ braking ability. Methods 14 patients with right knee osteoarthritis were included in the present study and instructed to perform three simulated driving tasks at preoperative, 2 weeks postoperative and 4 weeks postoperative. Results The results showed that the total braking time at 4 week postoperative has attained the preoperative level at the driving speed 50 and 70 km/hr but not at the driving speed 90 km/hr. It had significantly improving in knee reaction time and maximum isometric force at 4 weeks postoperative. Besides, there was a moderate to high correlation between the scores of the step counts and the total braking time. Conclusions Summary, it is recommended that driving may be resumed 4 weeks after a right knee replacement but had to drive at low or moderate speed and the best predictor of safety driving is step counts. PMID:24913312

  9. Influence of bi- and tri-compartmental knee arthroplasty on the kinematics of the knee joint

    PubMed Central

    2011-01-01

    Background The cruciate ligaments are important stabilizers of the knee joint and determine joint kinematics in the natural knee and after cruciate retaining arthroplasty. No in vitro data is available to biomechanically evaluate the ability of the anterior cruciate ligament (ACL) to maintain knee joint kinematics after bicruciate-retaining bi-compartmental knee arthroplasty (BKA). Therefore, the objective of the current study was to investigate the kinematics of the natural knee joint, before and after installing bicruciate-retaining BKA and posterior cruciate retaining total knee arthroplasty. Specifically, we incorporated a dynamic knee simulator to simulate weight-bearing flexions on cadaveric knee specimen before and after surgical manipulations. Methods In this cadaveric study we investigated rotational and translational tibiofemoral kinematics during simulated weight-bearing flexions of the intact knee, after bi-compartmental knee arthroplasty (BKA+), after resecting the ACL in BKA (BKA-), and after posterior cruciate retaining total knee arthroplasty (TKA). Results Rotation of BKA+ is closest to the intact knee joint, whereas TKA shows significant differences from 30 to 90 degree of flexion. Within the tested flexion range (15 to 90 degree of flexion), there was no significant difference in the anterior-posterior translation among intact, BKA+, and TKA knees. Resecting the ACL in BKA leads to a significant anterior tibial translation. Conclusions BKA with intact cruciate ligaments resembles rotation and translation of the natural knee during a simulated weight-bearing flexion. It is a suitable treatment option for medial and patellofemoral osteoarthritis with advantages in rotational characteristics compared to TKA. PMID:21272328

  10. [In vitro analysis of the continuous active patellofemoral kinematics of the normal and prosthetic knee].

    PubMed

    Jenny, J-Y; Lefèbvre, Y; Vernizeau, M; Lavaste, F; Skalli, W

    2002-12-01

    In vitro experiments are particularly useful for studying kinematic changes from the normal knee to experimental conditions simulating different disease states. We developed an experimental protocol allowing a kinematic analysis of the femorotibial and femoropatellar joints in the healthy knee and after implantation of a knee prosthesis, according to the central pivot during simulated active loaded movement from the standing to sitting position. An experimental device was designed to apply force to the femur of a cadaveric specimen including the femur, the patella and the tibia. The tibia was angled in the sagittal plane and the femur was free to move in space in response to the geometric movement of the knee joint, the capsuloligamentary structures, the quadriceps tendon and gravity. Variation in the length of the quadriceps tendon controlled the flexion-extension movement. The experimental setup included computer-controlled activation allowing continuous coordinated movement of the femur relative to the tibia and of the tibia relative to the ground. Standard activations simulated movement from the standing to the sitting position. Five pairs of fresh-frozen cadaver specimens including the entire femur, patella, tibia and fibula, the capsuloligamentary and intra-articular structures of the knee, the superior and inferior tibiofibular ligaments and the quadriceps tendon were studied. The quadriceps tendon was connected to the computer-guided activation device. Reflectors were fixed onto the anterior aspect of the femur, the superior tibial epiphysis and the center of the patella. Anatomic landmarks on the femur, the tibia, and the patella were identified to determine the plane of movement of each bone in the three rotation axes and the three translation directions. Three infrared cameras recorded movements of the reflectors fixed on the bony segments and, by mathematical transformation, the movement of the corresponding bony segment, displayed in time-course curves. The patella moved in continuous fashion over the femur, directly following the angle of knee flexion with a ratio of about 60%, which was constant for all knees studied and for all configurations. The patella of healthy knees and knees implanted with a unicompartmental prosthesis exhibited medial rotation during the first 30 degrees of flexion, with a movement of about of 10 degrees, then a lateral rotation of about 10 degrees to 20 degrees when the flexion reached 90 degrees; implantation of a total knee prosthesis led to a medial rotation which was continuous from 5 degrees to 15 degrees. There was a trend towards continuous abduction of about 10 degrees. The patella exhibited a continuous anterior translation of 10 to 20 mm from the tibia with increasing knee flexion, in both normal and prosthetic knees (unicompartmental prosthesis); knees implanted with a total knee prosthesis exhibited 5 to 10 mm anterior translation from 0 degrees to 50 degrees flexion, then an equivalent posterior translation for 50 degrees to 90 degrees flexion. The patella made a continuous 5 to 10 mm medial translation movement over the tibia in both normal and prosthetic (unicompartmental) knees; knees implanted with a total knee prosthesis exhibited 0 to 5 mm lateral translation starting after 50 degrees flexion. The patella also exhibited a continuous distal translation over the tibia of about 20 to 30 mm, for all configurations. The experimental set up enables a comparison of the kinetics of a normal knee with the kinetics observed after implantation of a prosthesis on the same knee. Implantation of a unicompartmental medial prosthesis, leaving the posterior cruciate ligament intact and irrespective of the status of the anterior cruciate ligament, did not, in these experimental conditions, exhibit any significant difference in the femorotibial or femoropatellar kinetics compared with the same normal knee. Implantation of a total knee prosthesis had a significant effect on the femoropatellar kinematics, compared with the same knee before implantation. The main anomalies were related to the medial-lateral rotation of the patella which exhibited an abnormal lateral rotation, possibly favorable for subluxation; these changes were directly related to femorotibial rotation after implantation of the total prosthesis and appeared to be related to the symmetry of the femoral condyles of the prosthesis model studied, perturbing the normal automatic rotation of the knee. There is thus a strong relationship between femorotibial and femoropatellar kinetics in the total knee prosthesis.

  11. A Novel, Nonoperative Treatment Demonstrates Success for Stiff Total Knee Arthroplasty after Failure of Conventional Therapy.

    PubMed

    Chughtai, Morad; Mont, Michael A; Cherian, Chris; Cherian, Jeffrey Jai; Elmallah, Randa D K; Naziri, Qais; Harwin, Steven F; Bhave, Anil

    2016-04-01

    Certain patients continue to suffer from knee stiffness following total knee arthroplasty (TKA) despite undergoing conventional therapies. Astym therapy to these patients may offer an effective, safe, nonoperative treatment. This study evaluates the effects of Astym therapy upon (1) range of motion and (2) subjective functional improvements in post-TKA patients who suffered from stiffness recalcitrant to other nonoperative interventions. Twenty-three post-TKA patients (29 knees) who had recalcitrant knee stiffness were included in this study. Pre- and post-Astym improvements in range of motion and Knee Society scores were compared. We analyzed knees based on the presence of flexion deficit or contracture. Further stratification was made into knees that received Astym therapy before and after a 3-month period of standard rehabilitation. Differences in range of motion from pre- to post-Astym were evaluated by measuring (1) degree of flexion deficit or contracture and (2) total arc of passive motion. Improvements in subjective functional status were determined by evaluating Knee Society scores pre- and post-Astym therapy. A two-tailed Student t-test was used to compare weighted mean differences from pre- to post-Astym for the above parameters. The mean flexion deficit improved significantly (p < 0.001) in all patients after Astym therapy. The mean flexion contracture improved significantly in (p = 0.001) in 91% of patients after Astym therapy. Knees with flexion deficits or contractures both improved in total arc of motion when compared with pretherapy. Overall, patients who underwent treatment with Astym therapy reported significant mean improvements in both Knee Society objective (80 vs. 57 points; p < 0.0001) and functional scores (80 vs. 54 points; p = 0.0003) when compared with their pretherapy objective and functional scores. No harms were reported. Astym therapy is a novel, nonoperative treatment that may be an effective treatment option for post-TKA patients suffering from persistent knee stiffness. Further studies are needed to validate this intervention as a part of cost-effective, standard treatment after TKA. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  12. The association between lower extremity energy absorption and biomechanical factors related to anterior cruciate ligament injury.

    PubMed

    Norcross, Marc F; Blackburn, J Troy; Goerger, Benjamin M; Padua, Darin A

    2010-12-01

    Greater total energy absorption by the lower extremity musculature during landing may reduce stresses placed on capsuloligamentous tissues with differences in joint contributions to energy absorption potentially affecting anterior cruciate ligament injury risk. However, the relationships between energy absorption and prospectively identified biomechanical factors associated with non-contact anterior cruciate ligament injury have yet to be demonstrated. Sagittal plane total, hip, knee and ankle energy absorption, and peak vertical ground reaction force, anterior tibial shear force, knee flexion and knee valgus angles, and internal hip extension and knee varus moments were measured in 27 individuals (14 females, 13 males) performing double leg jump landings. Correlation coefficients assessed the relationships between energy absorption during three time intervals (initial impact phase, terminal phase, and total landing) and biomechanical factors related to anterior cruciate ligament injury. More favorable values of biomechanical factors related to non-contact anterior cruciate ligament injury were associated with: 1) Lesser total (R(2)=0.178-0.558), hip (R(2)=0.229-0.651) and ankle (R(2)=0.280), but greater knee (R(2)=0.147) energy absorption during the initial impact phase; 2) Greater total (R(2)=0.170-0.845), hip (R(2)=0.599), knee (R(2)=0.236-0.834), and ankle (R(2)=0.276) energy absorption during the terminal phase of landing; and 3) Greater knee (R(2)=0.158-0.709), but lesser hip (R(2)=0.309) and ankle (R(2)=0.210-0.319) energy absorption during the total landing period. These results suggest that biomechanical factors related to anterior cruciate ligament injury are influenced by both the magnitude and timing of lower extremity energy absorption during landing. Copyright © 2010 Elsevier Ltd. All rights reserved.

  13. The AViKA (Adding Value in Knee Arthroplasty) postoperative care navigation trial: rationale and design features.

    PubMed

    Losina, Elena; Collins, Jamie E; Daigle, Meghan E; Donnell-Fink, Laurel A; Prokopetz, Julian J Z; Strnad, Doris; Lerner, Vladislav; Rome, Benjamin N; Ghazinouri, Roya; Skoniecki, Debra J; Katz, Jeffrey N; Wright, John

    2013-10-12

    Utilization of total knee arthroplasty is increasing rapidly. A substantial number of total knee arthroplasty recipients have persistent pain after surgery. Our objective was to design a randomized controlled trial to establish the efficacy of a motivational-interviewing-based telephone intervention aimed at improving patient outcomes and satisfaction following total knee arthroplasty. The study was conducted at Brigham and Women's Hospital in Boston, Massachusetts. The study focused on individuals 40 years or older with a primary diagnosis of osteoarthritis who were scheduled for total knee arthroplasty. The study compared two management strategies over the first six months postoperatively: 1) enhanced postoperative care with frequent follow-up by a care navigator; 2) usual postoperative care. Those who were randomized into the enhanced postoperative care arm received ten calls from a trained non-clinician care navigator over the first six postoperative months. The navigator used motivational interviewing techniques to engage patients in discussions related to their rehabilitation goals, including patient's plans for and confidence in achieving those goals. Patients in the usual care arm received standard postoperative management and received no navigator phone calls. Patients in both arms were assessed at baseline, three months, and six months postoperatively. The primary outcome of the study was improvement in function as measured by the difference in Western Ontario and McMaster Universities Osteoarthritis Index function score between preoperative (baseline) status and six months postoperatively. Data were collected to identify factors that may be related to total knee arthroplasty outcomes, including preoperative pain, pain catastrophizing, self-efficacy, and depression. A formal economic analysis is also planned to determine the cost-effectiveness of the care navigator as a component of total knee arthroplasty care. ClinicalTrials.gov NCT01540851.

  14. The Cost of Joint Replacement: Comparing Two Approaches to Evaluating Costs of Total Hip and Knee Arthroplasty.

    PubMed

    Palsis, John A; Brehmer, Thomas S; Pellegrini, Vincent D; Drew, Jacob M; Sachs, Barton L

    2018-02-21

    In an era of mandatory bundled payments for total joint replacement, accurate analysis of the cost of procedures is essential for orthopaedic surgeons and their institutions to maintain viable practices. The purpose of this study was to compare traditional accounting and time-driven activity-based costing (TDABC) methods for estimating the total costs of total hip and knee arthroplasty care cycles. We calculated the overall costs of elective primary total hip and total knee replacement care cycles at our academic medical center using traditional and TDABC accounting methods. We compared the methods with respect to the overall costs of hip and knee replacement and the costs for each major cost category. The traditional accounting method resulted in higher cost estimates. The total cost per hip replacement was $22,076 (2014 USD) using traditional accounting and was $12,957 using TDABC. The total cost per knee replacement was $29,488 using traditional accounting and was $16,981 using TDABC. With respect to cost categories, estimates using traditional accounting were greater for hip and knee replacement, respectively, by $3,432 and $5,486 for personnel, by $3,398 and $3,664 for space and equipment, and by $2,289 and $3,357 for indirect costs. Implants and consumables were derived from the actual hospital purchase price; accordingly, both methods produced equivalent results. Substantial cost differences exist between accounting methods. The focus of TDABC only on resources used directly by the patient contrasts with the allocation of all operating costs, including all indirect costs and unused capacity, with traditional accounting. We expect that the true costs of hip and knee replacement care cycles are likely somewhere between estimates derived from traditional accounting methods and TDABC. TDABC offers patient-level granular cost information that better serves in the redesign of care pathways and may lead to more strategic resource-allocation decisions to optimize actual operating margins.

  15. Relationship between Improvements in Physical Measures and Patient Satisfaction in Rehabilitation after Total Knee Arthroplasty

    ERIC Educational Resources Information Center

    Nazzal, Mahmoud I.; Bashaireh, Khaldoon H.; Alomari, Mahmoud A.; Nazzal, Mohammad S.; Maayah, Mikhled F.; Mesmar, Mohammad

    2012-01-01

    The aim of this study was to examine patient satisfaction with rehabilitation after total knee arthroplasty (TKA). Fifty-six patients, aged 45-77 years, were enrolled in a post-TKA comprehensive therapy program focusing on knee strengthening and functional activities. The program lasted 3 months and was conducted for 1 h, twice a day, 5 days per…

  16. Influence of conformity on the wear of total knee replacement: An experimental study

    PubMed Central

    Brockett, Claire L; Carbone, Silvia; Fisher, John; Jennings, Louise M

    2017-01-01

    Wear of total knee replacement continues to be a significant factor influencing the clinical longevity of implants. Historically, failure due to delamination and fatigue directed design towards more conforming inserts to reduce contact stress. As new generations of more oxidatively stable polyethylene have been developed, more flexibility in bearing design has been introduced. The aim of this study was to investigate the effect of insert conformity on the wear performance of a fixed bearing total knee replacement through experimental simulation. Two geometries of insert were studied under standard gait conditions. There was a significant reduction in wear with reducing implant conformity. This study has demonstrated that bearing conformity has a significant impact on the wear performance of a fixed bearing total knee replacement, providing opportunities to improve clinical performance through enhanced material and design selection. PMID:29251167

  17. Comparison of Floseal(r) and electrocautery in hemostasis after total knee arthroplasty

    PubMed Central

    Helito, Camilo Partezani; Gobbi, Riccardo Gomes; Castrillon, Lucas Machado; Hinkel, Betina Bremer; Pécora, José Ricardo; Camanho, Gilberto Luis

    2013-01-01

    Objective To evaluate whether hemostasis with eletrocauterization in comparison with Floseal(r) leads to different bleeding rates during total knee arthroplasty. Methods A comparative study was performed between two groups: group with ten consecutive total knee arthroplasties with Floseal(r) used as hemostatic method and control group with ten consecutive total knee arthroplasties with eletrocauterization as hemostatic method. Bleeding parameters such as debit of the drain, liquid infusion and blood transfusion rate were recorded. Results Floseal(r) group received less blood transfusion, less liquid infusion and lower drainage in absolute numbers compared to the control group. However, no parameter was statistically significant. Conclusion Hemostasis with Floseal(r) is as effective as hemostasis with eletrocauterization, what makes it a viable alternative to patients with contraindication to electric scalpel use. Level of Evidence II, Prospective Comparative Study. PMID:24453689

  18. The influence of tourniquet use and operative time on the incidence of deep vein thrombosis in total knee arthroplasty.

    PubMed

    Hernandez, Arnaldo José; Almeida, Adriano Marques de; Fávaro, Edmar; Sguizzato, Guilherme Turola

    2012-09-01

    To evaluate the association between tourniquet and total operative time during total knee arthroplasty and the occurrence of deep vein thrombosis. Seventy-eight consecutive patients from our institution underwent cemented total knee arthroplasty for degenerative knee disorders. The pneumatic tourniquet time and total operative time were recorded in minutes. Four categories were established for total tourniquet time: <60, 61 to 90, 91 to 120, and >120 minutes. Three categories were defined for operative time: <120, 121 to 150, and >150 minutes. Between 7 and 12 days after surgery, the patients underwent ascending venography to evaluate the presence of distal or proximal deep vein thrombosis. We evaluated the association between the tourniquet time and total operative time and the occurrence of deep vein thrombosis after total knee arthroplasty. In total, 33 cases (42.3%) were positive for deep vein thrombosis; 13 (16.7%) cases involved the proximal type. We found no statistically significant difference in tourniquet time or operative time between patients with or without deep vein thrombosis. We did observe a higher frequency of proximal deep vein thrombosis in patients who underwent surgery lasting longer than 120 minutes. The mean total operative time was also higher in patients with proximal deep vein thrombosis. The tourniquet time did not significantly differ in these patients. We concluded that surgery lasting longer than 120 minutes increases the risk of proximal deep vein thrombosis.

  19. Gait Parameters and Functional Outcomes After Total Knee Arthroplasty Using Persona Knee System With Cruciate Retaining and Ultracongruent Knee Inserts.

    PubMed

    Rajgopal, Ashok; Aggarwal, Kalpana; Khurana, Anshika; Rao, Arun; Vasdev, Attique; Pandit, Hemant

    2017-01-01

    Total knee arthroplasty is a well-established treatment for managing end-stage symptomatic knee osteoarthritis. Currently, different designs of prostheses are available with majority ensuring similar clinical outcomes. Altered surface geometry is introduced to strive toward gaining superior outcomes. We aimed to investigate any differences in functional outcomes between 2 different polyethylene designs namely the Persona CR (cruciate retaining) and Persona UC (ultracongruent) tibial inserts (Zimmer-Biomet, Warsaw, IN). This prospective single blind, single-surgeon randomized controlled trial reports on 105 patients, (66 female and 39 male), who underwent simultaneous bilateral total knee arthroplasty using the Persona knee system (Zimmer-Biomet) UC inserts in one side and CR inserts in the contralateral side. By a blind assessor, at regular time intervals patients were assessed in terms of function and gait. The functional knee scoring scales used were the Western Ontario and McMaster Universities Osteoarthritis Index and Modified Knee Society Score. The gait parameters evaluated were foot pressure and step length. During the study period, no patient was lost to follow-up or underwent revision surgery for any cause. Western Ontario and McMaster Universities Osteoarthritis Index scores, Modified Knee Society Score, and knee range of motion of all 105 patients assessed preoperatively and postoperatively at 6 months, 1 year, and 2 years showed statistically better results (P < .05) for UC inserts. Gait analysis measuring foot pressures and step length, however, did not show any statistically significant differences at 2-year follow-up. Ultracongruent tibial inserts show significantly better functional outcomes as compared to CR inserts during a 2-year follow-up period. However, in this study these findings were not shown to be attributed to differences in gait parameters. Copyright © 2016 Elsevier Inc. All rights reserved.

  20. Does high flexion after total knee replacement really improve our patients' quality of life at a short-term follow-up? : a comparative case-control study with hyperflex PFC Sigma versus a Triathlon knee series.

    PubMed

    Mencière, Maxime L; Epinette, Jean-Alain; Gabrion, Antoine; Arnalsteen, Damien; Mertl, Patrice

    2014-10-01

    A full range of motion after total knee arthroplasty has become more and more requested by our patients, leading to novel designs of knee implants, the so-called "hyperflex" knees. The aim of the present study was to confirm whether or not hyperflexion of operated knees really improves the patients' quality of life. A retrospective comparative case-control study has been carried out to compare clinical results shown in two types of knee prosthesis, from two homogeneous paired groups of patients including 45 cases of a "hyperflex" model (RP-F), while the control group consisted of 43 cases of a "regular design" model (Triathlon) in terms of expected postoperative flexion. The hyperflex group demonstrated significant higher mean values of passive flexion at 119.9° in the RP-F group versus 111.1° in the Triathlon group. However, global results in the "regular" control group were significantly better than the "hyperflex" study group, in both IKS knee and functional scores at 84.4 points (RP-F) vs. 89.8 points (Triathlon), and 84.6 points (RP-F) vs. 89.5 points (Triathlon), respectively. Moreover, the self-administered KOOS questionnaire was significantly in favor of the control group, with 73.5 points in RP-F knees versus 86.0 points for Triathlon knees at global KOOS postoperative scores. The quality of life of operated patients after TKA obviously would be considered as the main priority, which was better obtained by a "regular design" in our study. Hence "high flexion" cannot be considered as an absolute target when choosing a model for total knee arthroplasty.

  1. Calcaneal stress fracture: an adverse event following total hip and total knee arthroplasty: a report of five cases.

    PubMed

    Miki, Takaaki; Miki, Takahito; Nishiyama, Akihiro

    2014-01-15

    Stress fractures have been reported to occur in the pubis, femoral neck, proximal part of the tibia, and fabella during the postoperative period following total knee or total hip arthroplasty. However, to our knowledge, calcaneal stress fractures after total hip or total knee arthroplasty have not been reported in the English-language literature. Most orthopaedic surgeons are not familiar with calcaneal stress fractures that may occur in elderly patients after a total knee or total hip arthroplasty. We retrospectively reviewed the clinical features, imaging findings, and bone mineral content of the proximal part of the femur and the distal end of the radius in five patients who had a calcaneal stress fracture after a total knee or total hip arthroplasty. All patients were women with a mean age of 76.8 years. All fractures occurred in the calcaneus on the same side as the arthroplasty. The fracture appeared at a mean of 10.2 weeks postoperatively. All patients reported heel pain on walking. Swelling and local heat were found in four and three patients, respectively. Pain was elicited by squeezing the calcaneus in all patients. Early radiographs had normal findings in two patients, and an irregular sclerotic line appeared later in the radiographs of all patients. All fractures were treated conservatively. Four fractures healed uneventfully, but one fracture displaced. All patients had osteoporosis. Calcaneal stress fractures during the postoperative period following total knee or total hip arthroplasty may not be as rare as previously thought. Because clinical symptoms of the fracture appear insidiously and radiographic findings are absent or subtle in the early stage, a high index of suspicion is needed for orthopaedic surgeons to make the correct diagnosis. Magnetic resonance imaging or repeated radiographs may be necessary to make the correct diagnosis when no abnormality is apparent on the initial radiograph.

  2. Do Changes in Patellofemoral Joint Offset Lead to Adverse Outcomes in Total Knee Arthroplasty With Patellar Resurfacing? A Radiographic Review.

    PubMed

    Matz, Jacob; Howard, James L; Morden, David J; MacDonald, Steven J; Teeter, Matthew G; Lanting, Brent A

    2017-03-01

    Patellofemoral joint biomechanics contribute to anterior knee pain, instability, and dysfunction following total knee arthroplasty (TKA). Information about specific factors leading to anterior knee pain and dysfunction is currently limited. Changes in patellofemoral joint offset (PFO) refers to a mismatch between the preoperative and postoperative anteroposterior geometry of the patellofemoral joint. It remains unclear whether these changes lead to adverse outcomes in TKA. A retrospective radiographic review of 970 knees pre-TKA and post-TKA was completed to correlate the radiographic and clinical outcomes of changing the PFO using a posterior-stabilized single knee design with patellar resurfacing. A total of 970 patients were reviewed. Postoperatively, the anterior femoral offset, anteroposterior femoral size, and anterior patellar offset were changed in 40%, 60%, and 71% of knees, respectively, compared to preoperative values. The Western Ontario and McMasters Osteoarthritis Index total score as well as subscale scores for pain and function were not significantly affected by an increase or decrease in PFO. Similarly, Knee Society Scores and range of motion were not significantly affected. Increased anterior patellar offset was, however, associated with increased postoperative patellar tilt. Postoperative patellar tilt was not correlated with adverse patient satisfaction scores or loss of range of motion. Changes in PFO (decreased, maintained, or increased) are common post-TKA and are not associated with a difference in clinical outcomes. Increases in anterior patellar offset led to increased patellar tilt, which was not associated with adverse patient satisfaction scores. Copyright © 2016 Elsevier Inc. All rights reserved.

  3. Fixation of periprosthetic femur fractures above total knee arthroplasty with the less invasive stabilization system: a midterm follow-up study.

    PubMed

    Kolb, Werner; Guhlmann, Hanno; Windisch, Christoph; Marx, Frank; Koller, Heiko; Kolb, Klaus

    2010-09-01

    The complication rate of periprosthetic femoral fractures above well-fixed total knee arthroplasties is high. The Less Invasive Stabilization System (LISS) was introduced to reduce surgical dissections at the fracture site. The purpose of this retrospective study was to evaluate the midterm functional outcome of a group of patients with periprosthetic fractures above well-fixed total knee arthroplasties treated with the LISS. Between January 1999 and June 2004, 23 consecutive patients (all women) with periprosthetic fractures above well-fixed total knee arthroplasties were treated with the LISS. The mean age was 77 years (range, 61-90 years). Nineteen of the patients (83%) were seen after a midterm follow-up of 46 months (range, 26-67 months). Three patients (13%) died, and one patient (4%) was lost to follow-up. A proximal screw pull-out of the internal fixator occurred in one patient (4%). All fractures healed within a mean of 14 weeks (range, 9-21 weeks). No bone graft was required. There were two delayed unions, no nonunions or infections. One patient (4%) had a malalignment with 7° varus. The mean range of motion was 102° (range, 65-120°). The mean knee score of the Knee Society was 81 points (range, 65-90 points), and the mean function score of the Knee Society was 56 points (range, 35-90 points). We found that a minimally invasive, locked plating system permitted stable fixation, early knee motion with good midterm results, and minimal complications. These techniques should be used in place of less stable and more invasive methods.

  4. Chronic Quadriceps Tendon Rupture After Total Knee Arthroplasty Augmented With Synthetic Mesh.

    PubMed

    Ormaza, Amaia; Moreta, Jesús; Mosquera, Javier; de Ugarte, Oskar Sáez; Mozos, José Luis Martinez-de Los

    2017-01-01

    Tear of the quadriceps tendon after revision or primary total knee arthroplasty is a rare complication, but when it occurs, this injury has serious functional consequences. In complete tears, the outcome of direct repair is unpredictable, and several authors recommend that the suture should be reinforced. Several techniques have been described, including the use of autografts, allografts, and synthetic mesh. The goal of this study was to assess the outcomes of a reconstruction technique augmented with synthetic mesh. A retrospective study was performed involving 3 patients who had chronic partial quadriceps tendon tear after total knee revision. In 2 cases, proximal quadriceps release was performed. When conservative management failed, surgical reconstruction with suture reinforced with synthetic mesh was attempted. The knee was immobilized in full extension for 6 weeks after the surgical procedure. A minimum follow-up of 12 months was required to assess results. All reconstructions showed clinical success at a mean follow-up of 19 months. Mean Knee Society Score improved from 55.7 to 87.3, with average postoperative extensor lag of 3.3° (range, 0°-10°). The mean visual analog scale pain score was 2.3 (range, 0-4). No complications were reported. Synthetic mesh has previously been shown to be an effective treatment for patellar tendon repairs after total knee replacement, but there have been few articles on quadriceps rupture. Surgical reconstruction with synthetic mesh is a viable option that provides good functional outcomes in chronic quadriceps tendon rupture after total knee arthroplasty. [Orthopedics. 2017; 40(1):38-42.]. Copyright 2016, SLACK Incorporated.

  5. Reductions in knee joint forces with weight loss are attenuated by gait adaptations in class III obesity.

    PubMed

    DeVita, Paul; Rider, Patrick; Hortobágyi, Tibor

    2016-03-01

    A consensus exists that high knee joint forces are a precursor to knee osteoarthritis and weight loss reduces these forces. Because large weight loss also leads to increased step length and walking velocity, knee contact forces may be reduced less than predicted by the magnitude of weight loss. The purpose was to determine the effects of weight loss on knee muscle and joint loads during walking in Class III obese adults. We determined through motion capture, force platform measures and biomechanical modeling the effects of weight loss produced by gastric bypass surgery over one year on knee muscle and joint loads during walking at a standard, controlled velocity and at self-selected walking velocities. Weight loss equaling 412 N or 34% of initial body weight reduced maximum knee compressive force by 824 N or 67% of initial body weight when walking at the controlled velocity. These changes represent a 2:1 reduction in knee force relative to weight loss when walking velocity is constrained to the baseline value. However, behavioral adaptations including increased stride length and walking velocity in the self-selected velocity condition attenuated this effect by ∼50% leading to a 392 N or 32% initial body weight reduction in compressive force in the knee joint. Thus, unconstrained walking elicited approximately 1:1 ratio of reduction in knee force relative to weight loss and is more indicative of walking behavior than the standard velocity condition. In conclusion, massive weight loss produces dramatic reductions in knee forces during walking but when patients stride out and walk faster, these favorable reductions become substantially attenuated. Copyright © 2016 Elsevier B.V. All rights reserved.

  6. The influence of motion control shoes on the running gait of mature and young females.

    PubMed

    Lilley, Kim; Stiles, Vicky; Dixon, Sharon

    2013-03-01

    This study compared the running gait of mature and young females, and investigated the effect of a motion control shoe. First, it was hypothesised that in a neutral shoe, mature females would display significantly greater rearfoot eversion, knee internal rotation and external adductor moments when compared to a younger group. Secondly, the motion control shoe would reduce rearfoot eversion and knee internal rotation in both groups. Thirdly it was hypothesised that the motion control shoe would increase knee external adductor moment, through an increase in knee varus and moment arm. 15 mature (40-60 years) and 15 young (18-25 years) females performed 10 running trials at 3.5ms(-1)±5% over a force platform. Two shoes were tested, the Adidas Supernova Glide (neutral), and the Adidas Supernova Sequence (motion control). Ankle and knee joint dynamics were analysed for the right leg, and the mean of ten trials was calculated. Joint moments were calculated using inverse dynamics. In the neutral condition, mature females presented greater peak rearfoot eversion, knee internal rotation, and external adductor moments than young females (p<0.05). A motion control shoe significantly reduced peak rearfoot eversion and knee internal rotation among both groups (p<0.05). No between shoe differences in knee external adductor moment were observed. A motion control shoe is recommended to reduce risk of injury associated with rearfoot eversion and knee internal rotation in mature females. However since the knee external adductor moment is a variable commonly associated with medial knee loading it is suggested that alternative design features are required to influence this moment. Copyright © 2012 Elsevier B.V. All rights reserved.

  7. Histopathological Evaluation of the Anterior Cruciate Ligament in Patients Undergoing Primary Total Knee Arthroplasty.

    PubMed

    Mont, Michael A; Elmallah, Randa K; Cherian, Jeffrey J; Banerjee, Samik; Kapadia, Bhaveen H

    2016-01-01

    This study assessed gross and histopathological ACL changes in arthritic knees (n=174) undergoing total knee arthroplasty. Histopathological changes were assessed and graded as absent (0), mild (1), moderate (2), or marked (3). These were correlated to demographic and clinical factors, and radiographic evaluations. The ACL was intact in 43, frayed in 85, torn in 15, and absent in 31 knees. Eighty-five percent had histological changes. Overall, there were significant associations between greater age and BMI, and histological changes. Grade IV knees had significantly greater calcium pyrophosphate deposits, microcyst formation, and number of pathologic changes. These correlations may aid decision-making when determining suitability for unicompartmental or bicruciate-retaining arthroplasties, though further studies should correlate these histological findings to mechanical and functional knee status. Copyright © 2016 Elsevier Inc. All rights reserved.

  8. Self-Reported Knee Instability Before and After Total Knee Replacement Surgery.

    PubMed

    Fleeton, Genevieve; Harmer, Alison R; Nairn, Lillias; Crosbie, Jack; March, Lyn; Crawford, Ross; van der Esch, Martin; Fransen, Marlene

    2016-04-01

    To determine the prevalence and burden of pain and activity limitations associated with retaining presurgery self-reported knee instability 6 months after total knee replacement (TKR) surgery and to identify early potentially modifiable risk factors for retaining knee instability in the operated knee after TKR surgery. A secondary analysis was performed using measures obtained from 390 participants undergoing primary unilateral TKR and participating in a randomized clinical trial. Self-reported knee instability was measured using 2 items from the Activities of Daily Living Scale of the Knee Outcome Survey. Outcome measures were knee pain (range 0-20) and physical function (range 0-68) on the Western Ontario and McMaster Universities Arthritis Index (WOMAC), stair-climb power, 50-foot walk time, knee range of motion, and isometric knee flexion and extension strength. In this study, 72% of participants reported knee instability just prior to surgery, with 32% retaining instability in the operated knee 6 months after surgery. Participants retaining operated knee instability had significantly more knee pain and activity limitations 6 months after surgery, with mean ± SD WOMAC scores of 4.8 ± 3.7 and 17.5 ± 11.1, respectively, compared to participants without knee instability, with 2.9 ± 3.1 and 9.8 ± 9.2. The multivariable predictor model for retained knee instability included a high comorbidity score (>6), low stair-climb power (<150 watts), more pain in the operated knee (>7 of 20), and younger age (<60 years). Self-reported knee instability is highly prevalent before and after TKR surgery and is associated with a considerable burden of pain and activity limitation in the operated knee. Increasing lower extremity muscle power may reduce the risk of retaining knee instability after TKR surgery. © 2016, American College of Rheumatology.

  9. Results of press-fit stems in revision knee arthroplasties.

    PubMed

    Wood, Gavin C; Naudie, Douglas D R; MacDonald, Steven J; McCalden, Richard W; Bourne, Robert B

    2009-03-01

    The ideal method of stem fixation in revision knee arthroplasty is controversial with advantages and disadvantages for cemented and press-fit designs. Studies have suggested cemented revision knee stems may provide better long-term survival. The aim of this study was to report our experience with press-fit uncemented stems and metaphyseal cement fixation in a selected series of patients undergoing revision total knee arthroplasty. One hundred twenty-seven patients (135 knees) who underwent revision total knee arthroplasty using a press-fit technique (press-fit diaphyseal fixation and cemented metaphyseal fixation) were reviewed. Minimum followup was 2 years (mean, 5 years; range, 2-12 years). A Kaplan-Meier survivorship analysis using an end point of revision surgery or radiographic loosening was used to determine probability of survival at 5 and 10 years. Of the 127 patients (135 knees), 31 patients (36 knees) died and two patients (two knees) were lost to followup. Six patients (six knees) had revisions at a mean of 3.5 years (range, 1-8 years). Kaplan-Meier survivorship analysis revealed a probability of survival free of revision for aseptic loosening of 98% at 12 years. Survivorship of press-fit stems for revision knee arthroplasty is comparable to reported survivorship of cemented stem revision knee arthroplasty. Radiographic analysis has shown continued satisfactory appearances regardless of constraint, stem size, and augmentations.

  10. Are external knee load and EMG measures accurate indicators of internal knee contact forces during gait?

    PubMed

    Meyer, Andrew J; D'Lima, Darryl D; Besier, Thor F; Lloyd, David G; Colwell, Clifford W; Fregly, Benjamin J

    2013-06-01

    Mechanical loading is believed to be a critical factor in the development and treatment of knee osteoarthritis. However, the contact forces to which the knee articular surfaces are subjected during daily activities cannot be measured clinically. Thus, the ability to predict internal knee contact forces accurately using external measures (i.e., external knee loads and muscle electromyographic [EMG] signals) would be clinically valuable. We quantified how well external knee load and EMG measures predict internal knee contact forces during gait. A single subject with a force-measuring tibial prosthesis and post-operative valgus alignment performed four gait patterns (normal, medial thrust, walking pole, and trunk sway) to induce a wide range of external and internal knee joint loads. Linear regression analyses were performed to assess how much of the variability in internal contact forces was accounted for by variability in the external measures. Though the different gait patterns successfully induced significant changes in the external and internal quantities, changes in external measures were generally weak indicators of changes in total, medial, and lateral contact force. Our results suggest that when total contact force may be changing, caution should be exercised when inferring changes in knee contact forces based on observed changes in external knee load and EMG measures. Advances in musculoskeletal modeling methods may be needed for accurate estimation of in vivo knee contact forces. Copyright © 2012 Orthopaedic Research Society.

  11. [Joint dislocation after total knee arthroplasty as an ankle fracture complication. Case report].

    PubMed

    Hrubina, M; Skoták, M

    2012-01-01

    Joint dislocation after total knee arthroplasty is a rare complication. It is described as the result of ligamentous instability. Here we report the case of an 82-year-old women who underwent primary total knee arthroplasty (TKA) for advanced primary grade III gonarthrosis. At 3 post-operative months the joint was stable and painless, with radiographic evidence of good TKA alignment and integration. At 4 months the patient suffered injury to the ankle involving a bimalleolar fracture and damage to knee soft tissues. The fracture was surgically treated. Subsequently, dorsal tibial dislocation was manifested. This was managed by individual intramedullary nail arthrodesis. At 8 months following the operation, the knee condition was satisfactory, with rigid arthrodesis and leg shortening of 4 cm. The patient was satisfied because she was free of pain and able to walk. Arthrodesis of the knee joint with an individual nail is an option for a definitive treatment of TKA instability. When other joints, such as ankle or hip joints, are injured, it is recommended to pay attention also to any TKA implanted previously because of potential development of instability or infection.

  12. Wound closure in flexion versus extension following total knee arthroplasty: a systematic review.

    PubMed

    Smith, Toby O; Davies, Leigh; Hing, Caroline B

    2010-06-01

    Optimising knee range of motion following total knee arthroplasty (TKA) is important for patient satisfaction, functional outcome and early rehabilitation to promote accelerated discharge. Historically, wound closure following TKA has been performed in extension. It has been suggested that knee position during wound closure may influence range of motion and clinical outcomes following TKA. The purpose of this study was to determine whether TKA wounds should be closed in flexion or extension. An electronic search of MEDLINE, EMBASE, CINAHL and AMED databases was made in addition to a review of unpublished material. All included papers were critically appraised using a modified PEDro (Physiotherapy Evidence Database) critical appraisal tool. Three papers were eligible, assessing 237 TKAs. On analysis, patients with TKA wounds closed in flexion had greater flexion range of motion and required less domiciliary physiotherapy compared to those with wounds closed in full extension. The specific degree of knee flexion used when closing total knee replacement wounds may be an important variable to clinical outcome. However, the present evidence-base is limited in both size and methodological quality.

  13. [Navigated implantation of total knee endoprostheses--a comparative study with conventional instrumentation].

    PubMed

    Jenny, J Y; Boeri, C

    2001-01-01

    A navigation system should improve the quality of a total knee prosthesis implantation in comparison to the classical, surgeon-controlled operative technique. The authors have implanted 40 knee total prostheses with an optical infrared navigation system (Orthopilot AESCULAP, Tuttlingen--group A). The quality of implantation was studied on postoperative long leg AP and lateral X-rays, and compared to a control group of 40 computer-paired total knee prostheses o the same model (Search Prosthesis, AESCULAP, Tuttlingen) implanted with a classical, surgeon-controlled technique (group B). An optimal mechanical femorotibial angle (3 degrees valgus to 3 degrees varus) was obtained by 33 cases in group A and 31 cases in group B (p > 0.05). Better results were seen for the coronal and sagittal orientation of both tibial and femoral components in group A. Globally, 26 cases of the group A and 12 cases of the group B were implanted in an optimal manner for all studied criteria (p < 0.01). The used navigation system allows a significant improvement of the quality of implantation of a knee total prosthesis in comparison to a classical, surgeon-controlled instrumentation. Long-term outcome could be consequently improved.

  14. Quantification of polyethylene degradation in mobile bearing knees: a retrieval analysis of the Anterior-Posterior-Glide (APG) and Rotating Platform (RP) Low Contact Stress (LCS) knee.

    PubMed

    Kop, Alan M; Swarts, Eric

    2007-06-01

    Routine qualitative observations of more than 850 polyethylene fixed and mobile bearings at our institution have noted minimal wear of mobile bearings. The APG mobile bearing is the most recent design variant of the LCS knee, allows multi-directional movement at the tibiofemoral articulation, and is posterior cruciate sparing. Even though it is difficult to perform, quantitative wear measurement is important in determining the likely longevity of new arthroplasty devices, and is especially relevant because of increasing numbers of new mobile bearing designs. We analyzed 10 retrieved APG and 7 retrieved RP tibial bearings (De Puy) with a mean implantation period of 33 (9-70) months. We used coordinate-measuring techniques to quantitatively determine linear penetration, and optical and scanning electron microscopy to assess wear mechanisms qualitatively. The mean total volume loss (superior and inferior articulations) of the APG and RP designs was 85 mm((3))/year and 77 mm((3))/year, respectively. Burnishing was the predominant wear mechanism, and to a lesser extent scratching, abrasion and pitting. Multidirectional scratching and abrasion were noted on the APG inserts inferiorly, whereas there was circumferential scratching on the RP inserts. Our short-term results for the APG and RP mobile bearing designs are similar and compare more than favorably with reported values for fixed-bearing designs. However, increased backside wear due to multidirectional movement may predispose the APG design to greater wear in the long term.

  15. Impact of Soft Tissue Imbalance on Knee Flexion Angle After Posterior Stabilized Total Knee Arthroplasty.

    PubMed

    Tsukada, Sachiyuki; Fujii, Tomoko; Wakui, Motohiro

    2017-08-01

    This study was performed to assess the impact of soft tissue imbalance on the knee flexion angle 2 years after posterior stabilized total knee arthroplasty (TKA). A total of 329 consecutive varus knees were included to assess the association of knee flexion angle 2 years after TKA with preoperative, intraoperative, and postoperative variables. All intraoperative soft tissue measurements were performed by a single surgeon under spinal anesthesia in a standardized manner including the subvastus approach, reduced patella, and without use of a pneumonic tourniquet. Multiple linear regression analysis showed no significant correlations in terms of intraoperative valgus imbalance at 90-degree flexion or the difference in soft tissue tension between 90-degree flexion and 0-degree extension (β = -0.039; 95% confidence interval [CI], -0.88 to 0.80; P = .93 and β = 0.015; 95% CI, -0.29 to 0.32; P = .92, respectively). Preoperative flexion angle was significantly correlated with knee flexion angle 2 years after TKA (β = 0.42; 95% CI, 0.33 to 0.51; P < .0001). Avoiding valgus imbalance at 90-degree flexion and aiming for strictly equal soft tissue tension between 90-degree flexion and 0-degree extension had little practical value with regard to knee flexion angle 2 years after posterior stabilized TKA. Copyright © 2017 The Author(s). Published by Elsevier Inc. All rights reserved.

  16. Soft tissue balancing in total knee arthroplasty using sensor-guided assessment: is there a learning curve?

    PubMed

    Gharaibeh, Monther A; Chen, Darren B; MacDessi, Samuel J

    2018-05-01

    Sensor-guided assessment for soft tissue balance in total knee arthroplasty (TKA) has been reported to improve patient satisfaction and self-reported outcome scores. As more surgeons adopt this technology in TKA, we performed this study to identify if there is a learning curve with its use. Analysis of a total of 90 consecutive cases was performed in this study. Initial and final intercompartmental pressure differences were recorded before and after knee ligament balancing. The first 45 patients (group 1) were compared to the last 45 patients (group 2) in terms of operative time and the final state of knee balance. A balanced knee was defined as pressure difference between medial and lateral compartments of ≤15 pounds. Group 1 had 10 unbalanced knees in the final pressure difference assessment, while all cases in group 2 were balanced (P < 0.001). There was no statistically significant difference in mean operative time between the two groups. A scatter plot of intercompartmental pressure difference identified that after 30 cases, the capacity to achieve knee ligament balance improved. This study suggests that there is a learning curve with the use of sensor-guided assessment in TKA in achieving knee balance; however, the differences noted between initial and final groups were small and may not be of clinical significance. © 2018 Royal Australasian College of Surgeons.

  17. No difference in in vivo polyethylene wear particles between oxidized zirconium and cobalt-chromium femoral component in total knee arthroplasty.

    PubMed

    Minoda, Yukihide; Hata, Kanako; Iwaki, Hiroyoshi; Ikebuchi, Mitsuhiko; Hashimoto, Yusuke; Inori, Fumiaki; Nakamura, Hiroaki

    2014-03-01

    Polyethylene wear particle generation is one of the most important factors affecting mid- to long-term results of total knee arthroplasties. Oxidized zirconium was introduced as a material for femoral components to reduce polyethylene wear generation. However, an in vivo advantage of oxidized zirconium on polyethylene wear particle generation is still controversial. The purpose of this study was to compare in vivo polyethylene wear particles between oxidized zirconium total knee prosthesis and conventional cobalt-chromium (Co-Cr) total knee prosthesis. Synovial fluid was obtained from the knees of 6 patients with oxidized zirconium total knee prosthesis and from 6 patients with conventional cobalt-chromium (Co-Cr) total knee prosthesis 12 months after the operation. Polyethylene particles were isolated and examined using a scanning electron microscope and image analyser. Total number of particles in each knee was 3.3 ± 1.3 × 10(7) in the case of oxidized zirconium (mean ± SD) and 3.4 ± 1.2 × 10(7) in that of Co-Cr (n.s.). The particle size (equivalent circle diameter) was 0.8 ± 0.3 μm in the case of oxidized zirconium and 0.6 ± 0.1 μm in that of Co-Cr (n.s.). The particle shape (aspect ratio) was 1.4 ± 0.0 in the case of oxidized zirconium and 1.4 ± 0.0 in that of metal Co-Cr (n.s). Although newly introduced oxidized zirconium femoral component did not reduce the in vivo polyethylene wear particles in early clinical stage, there was no adverse effect of newly introduced material. At this moment, there is no need to abandon oxidized zirconium femoral component. However, further follow-up of polyethylene wear particle generation should be performed to confirm the advantage of the oxidized zirconium femoral component. Therapeutic study, Level III.

  18. Astym® Therapy for the Management of Recalcitrant Knee Joint Stiffness after Total Knee Arthroplasty.

    PubMed

    Bhave, Anil; Corcoran, James; Cherian, Jeffery J; Mont, Michael A

    2016-01-01

    Knee stiffness is a common complication after total knee arthroplasty (TKA). Despite studies published on the surgical management of reduced range of motion (ROM) after TKA, there is limited evidence on the nonoperative management of joint and soft tissue imbalances possibly contributing to reduced knee ROM. This report assesses changes in ROM, pain, function, and patellar tendon length after Astym® joint mobilization use. A 38-year-old male professional skier had a right TKA 3 months before presentation with 2 subsequent manipulations under anesthesia secondary to persistent knee stiffness. He had patellar baja on radiograph, a reduced arc of ROM, reduced patellar mobility and muscular extensibility, and pain to palpation along the patellar tendon. He had 12 visits of physical therapy with the use of Astym®, patellar mobilization, and tibio-femoral mobilizations with movement. The patient also used a customized knee device at home for prolonged knee extension stretching. The patient was treated for 12 visits, along with home use of customized bracing for knee extension. Significant improvements were seen in pain, function, and ROM. He returned to work full-time, ambulated prolonged distances, and negotiated stairs pain-free. He also demonstrated resolution of patellar baja radiographically. Conservative management of recalcitrant knee joint stiffness after primary TKA can be effective in restoring knee mobility and reducing pain and activity limitation. A multimodal approach using Astym® treatment, customized knee bracing, and targeted joint mobilization can be effective in resolving knee joint stiffness.

  19. Primary Total Knee Replacement: Is Suction a Portal of Infection?

    PubMed Central

    Budnar, Vijaya M; Amirfeyz, Rouin; Ng, Michael; Bannister, Gordon C; Blom, Ashley W

    2009-01-01

    INTRODUCTION Pulsed lavage during a total knee replacement usually leaves a pool of fluid on the surgical drapes. It is common practice to suck away this fluid using the same suction device used intra-operatively. This could be a cause of direct wound contamination. We hypothesised that bacteria contaminate fluid that collects around the foot in total knee replacement surgery and that suction equipment could be a portal of contamination. We also hypothesised that bacterial count in the fluid is lower if chlorhexidine, rather than saline, is used in the pulsed lavage. PATIENTS AND METHODS Forty patients undergoing primary total knee replacement were divided into two groups. The first group had pulsed lavage with normal saline and the second with 0.05% chlorhexidine. RESULTS At the end of the operation, 20 ml of fluid, pooled on the surgical drapes was aspirated and cultured for bacterial growth. None of the fluid samples showed bacterial growth. CONCLUSIONS Suction device used peri-operatively during knee replacement is unlikely to be a cause of wound contamination. Pulsed lavage with normal saline is as effective as lavage with chlorhexidine. PMID:19335972

  20. In vivo kinematics of a robot-assisted uni- and multi-compartmental knee arthroplasty.

    PubMed

    Watanabe, Toshifumi; Abbasi, Ali Z; Conditt, Michael A; Christopher, Jennifer; Kreuzer, Stefan; Otto, Jason K; Banks, Scott A

    2014-07-01

    There is great interest in providing reliable and durable treatments for one- and two-compartment arthritic degeneration of the cruciate-ligament intact knee. One approach is to resurface only the diseased compartments with discrete unicompartmental components, retaining the undamaged compartment(s). However, placing multiple small implants into the knee presents a greater surgical challenge than total knee arthroplasty, so it is not certain that the natural knee mechanics can be maintained or restored. The goal of this study was to determine whether near-normal knee kinematics can be obtained with a robot-assisted multi-compartmental knee arthroplasty. Thirteen patients with 15 multi-compartmental knee arthroplasties using haptic robotic-assisted bone preparation were involved in this study. Nine subjects received a medial unicompartmental knee arthroplasty (UKA), three subjects received a medial UKA and patellofemoral (PF) arthroplasty, and three subjects received medial and lateral bi-unicondylar arthroplasty. Knee motions were recorded using video-fluoroscopy an average of 13 months (6-29 months) after surgery during stair and kneeling activities. The three-dimensional position and orientation of the implant components were determined using model-image registration techniques. Knee kinematics during maximum flexion kneeling showed femoral external rotation and posterior lateral condylar translation. All knees showed femoral external rotation and posterior condylar translation with flexion during the step activity. Knees with medial UKA and PF arthroplasty showed the most femoral external rotation and posterior translation, and knees with bicondylar UKA showed the least. Knees with accurately placed uni- or bi-compartmental arthroplasty exhibited stable knee kinematics consistent with intact and functioning cruciate ligaments. The patterns of tibiofemoral motion were more similar to natural knees than commonly has been observed in knees with total knee arthroplasty. Larger series are required to confirm these as general observations, but the present results demonstrate the potential to restore or maintain closer-to-normal knee kinematics by retaining intact structures and compartments.

  1. Association Between Pain at Sites Outside the Knee and Knee Cartilage Volume Loss in Elderly People Without Knee Osteoarthritis: A Prospective Study.

    PubMed

    Pan, Feng; Laslett, Laura; Tian, Jing; Cicuttini, Flavia; Winzenberg, Tania; Ding, Changhai; Jones, Graeme

    2017-05-01

    Pain is common in the elderly. Knee pain may predict knee cartilage loss, but whether generalized pain is associated with knee cartilage loss is unclear. This study, therefore, aimed to determine whether pain at multiple sites predicts knee cartilage volume loss among community-dwelling older adults, and, if so, to explore potential mechanisms. Data from the prospective Tasmanian Older Adult Cohort study was utilized (n = 394, mean age 63 years, range 52-79 years). Experience of pain at multiple sites was assessed using a questionnaire at baseline. T1-weighted fat-saturated magnetic resonance imaging of the right knee was performed to assess the cartilage volume at baseline and after 2.6 years. Linear regression modeling was used with adjustment for potential confounders. The median number of painful sites was 3 (range 0-7). There was a dose-response relationship between the number of painful sites and knee cartilage volume loss in the lateral and total tibiofemoral compartments (lateral β = -0.28% per annum; total β = -0.25% per annum, both P for trend < 0.05), but not in the medial compartment. These associations were stronger in participants without radiographic knee osteoarthritis (OA) (P < 0.05) and independent of age, sex, body mass index, physical activity, pain medication, and knee structural abnormalities. The number of painful sites independently predicts knee cartilage volume loss, especially in people without knee OA, suggesting that widespread pain may be an early marker of more rapid knee cartilage loss in those without radiographic knee OA. The underlying mechanism is unclear, but it is independent of anthropometrics, physical activity, and knee structural abnormalities. © 2016, American College of Rheumatology.

  2. The treatment of recurrent chronic infected knee arthroplasty with a 2-stage procedure.

    PubMed

    Antoci, Valentin; Phillips, Matthew J; Antoci, Valentin; Krackow, Kenneth A

    2009-01-01

    We report the case of a patient with recurrent periprosthetic infections after total knee arthroplasty associated with bone destruction and massive bone loss that was successfully treated with a 2-stage procedure-resection arthroplasty with insertion of an antibiotic-impregnated cement rod-spacer and systemic antibiotics and then a resection arthrodesis of the knee with the use of an intercalary allograft fixed with a long intramedullary nail. This technique is a viable option for the treatment of recurrent periprosthetic infections after total knee arthroplasty associated with bone destruction, massive bone loss, and severe instability.

  3. Wichita fusion nail for patients with failed total knee arthroplasty and active infection.

    PubMed

    Barsoum, Wael K; Hogg, Christopher; Krebs, Viktor; Klika, Alison K

    2008-01-01

    In the study reported here, we retrospectively evaluated short-term results of knee arthrodesis using the Wichita fusion nail (WFN) in patients with active infection. Clinical examinations, x-rays, time to union, knee pain after fusion, and ambulatory status were compared in 7 patients who received the WFN. Mean fusion rate was 86%, mean time to fusion was 9.8 months, and mean complication rate was 57%. Complication rates were high, but clinical outcomes were acceptable, supporting use of WFN as a reasonable way to salvage failed total knee arthroplasty in patients with active infection.

  4. The importance of bony impingement in restricting flexion after total knee arthroplasty: computer simulation model with clinical correlation.

    PubMed

    Mizu-Uchi, Hideki; Colwell, Clifford W; Fukagawa, Shingo; Matsuda, Shuichi; Iwamoto, Yukihide; D'Lima, Darryl D

    2012-10-01

    We constructed patient-specific models from computed tomography data after total knee arthroplasty to predict knee flexion based on implant-bone impingement. The maximum flexion before impingement between the femur and the tibial insert was computed using a musculoskeletal modeling program (KneeSIM; LifeModeler, Inc, San Clemente, California) during a weight-bearing deep knee bend. Postoperative flexion was measured in a clinical cohort of 21 knees (low-flex group: 6 knees with <100° of flexion and high-flex group: 15 size-matched knees with >125° of flexion at 2 years). Average predicted flexion angles were within 2° of clinical measurements for the high-flex group. In the low-flex group, 4 cases had impingement involving the bone cut at the posterior condyle, and the average predicted knee flexion was 102° compared with 93° measured clinically. These results indicate that the level of the distal femoral resection should be carefully planned and that exposed bone proximal to the tips of the posterior condyles of the femoral component should be removed if there is risk of impingement. Copyright © 2012 Elsevier Inc. All rights reserved.

  5. Custom-fit total knee arthroplasty: our initial experience in 32 knees.

    PubMed

    Bali, Kamal; Walker, Peter; Bruce, Warwick

    2012-06-01

    We share our initial experience of total knee arthroplasty (TKA) using customized cutting block technology in 32 TKAs from May 2010 to March 2011. Ten of these patients had prior TKA done on the other side using conventional or navigation-assisted TKA. Customized cutting blocks were generated for each of the knee using preoperative magnetic resonance imaging of knee and long-leg weight-bearing radiographs. At 6 weeks, long-leg radiographs were obtained to evaluate the coronal alignment. There were no adverse intraoperative events. Twenty-nine of the 32 knees had a mechanical axis restored to within 3°° of neutral. Of 10 patients with prior TKA without custom-fit technology, the mean blood loss and the mean skin-to-skin time was found to be lower in knees that had undergone custom-fit TKA. We conclude that this technology can be safely used in most of the cases of osteoarthritis. Copyright © 2012 Elsevier Inc. All rights reserved.

  6. Transfusions and blood loss in total hip and knee arthroplasty: a prospective observational study.

    PubMed

    Carling, Malin S; Jeppsson, Anders; Eriksson, Bengt I; Brisby, Helena

    2015-03-28

    There is a high prevalence of blood product transfusions in orthopedic surgery. The reported prevalence of red blood cell transfusions in unselected patients undergoing hip or knee replacement varies between 21% and 70%. We determined current blood loss and transfusion prevalence in total hip and knee arthroplasty when tranexamic acid was used as a routine prophylaxis, and further investigated potential predictors for excessive blood loss and transfusion requirement. In total, 193 consecutive patients undergoing unilateral hip (n = 114) or knee arthroplasty (n = 79) were included in a prospective observational study. Estimated perioperative blood loss was calculated and transfusions of allogeneic blood products registered and related to patient characteristics and perioperative variables. Overall transfusion rate was 16% (18% in hip patients and 11% in knee patients, p = 0.19). Median estimated blood loss was significantly higher in hip patients (984 vs 789 mL, p < 0.001). Preoperative hemoglobin concentration was the only independent predictor of red blood cell transfusion in hip patients while low hemoglobin concentration, body mass index, and operation time were independent predictors for red blood cell transfusion in knee patients. The prevalence of red blood cell transfusion was lower than previously reported in unselected total hip or knee arthroplasty patients. Routine use of tranexamic acid may have contributed. Low preoperative hemoglobin levels, low body mass index, and long operation increase the risk for red blood cell transfusion.

  7. Semimembranosus Release for Medial Soft Tissue Balancing Does Not Weaken Knee Flexion Strength in Patients Undergoing Varus Total Knee Arthroplasty.

    PubMed

    Jang, Sung Won; Koh, In Jun; Kim, Man Soo; Kim, Ju Yeong; In, Yong

    2016-11-01

    The sequential medial release technique including semimembranosus (semiM) release is effective and safe during varus total knee arthroplasty (TKA). However, there are concerns about weakening of knee flexion strength after semiM release. We determined whether semiM release to balance the medial soft tissue decreased knee flexion strength after TKA. Fifty-nine consecutive varus knees undergoing TKA were prospectively enrolled. A 3-step sequential release protocol which consisted of release of (1) the deep medial collateral ligament (dMCL), (2) the semiM, and (3) the superficial medial collateral ligament based on medial tightness. Gap balancing was obtained after dMCL release in 31 knees. However, 28 knees required semiM release or more after dMCL release. Isometric muscle strength of the knee was compared 6 months postoperatively between the semiM release and semiM nonrelease groups. Knee stability and clinical outcomes were also compared. No differences in knee flexor or extensor peak torque were observed between the groups 6 months postoperatively (P = .322 and P = .383, respectively). No group difference was observed in medial joint opening angle on valgus stress radiographs (P = .327). No differences in the Knee Society or Western Ontario and McMaster Universities Osteoarthritis Index scores were detected between the groups (P = .840 and P = .682, respectively). These results demonstrate that semiM release as a sequential step to balance medial soft tissue in varus knees did not affect knee flexion strength after TKA. Copyright © 2016 Elsevier Inc. All rights reserved.

  8. Long-term outcome of 42 knees with chronic infection after total knee arthroplasty.

    PubMed

    Bose, W J; Gearen, P F; Randall, J C; Petty, W

    1995-10-01

    The outcome of treatment in 40 patients (42 knees) with chronic infections after total knee arthroplasty was reviewed. Eighteen knees were treated with a 2-stage reimplantation. Sixteen of these 18 knees were treated with antibiotic-containing beads between debridement and reimplantation, and 7 of these were also treated with antibiotics in the cement at reimplantation. Infection did not recur in any of these 18 knees. Clinically, the 2-stage reimplantation group averaged a score of 90 points on the Knee Society Clinical Rating System. Average function score was 86.5 points, with average range of motion from 2 degrees to 109 degrees. Sixteen knees were treated with an arthrodesis: 9 with a 1-stage technique with a uniplanar external fixator and 7 with a 2-stage technique with intramedullary nail internal fixation. Infection did not recur in 6 of 9 knees treated with the 1-stage technique, but only 2 had a solid arthrodesis. All 7 treated with the 2-stage intramedullary nail technique had no recurrence of infection and achieved a solid fusion. Reimplantation or arthrodesis was not attempted in 8 other knees because of recalcitrant infection, vascular complications, or medical infirmity. Of the 42 knees, 11 (26%) had a severely morbid outcome. The infection could not be eradicated in 7 knees: 6 required amputation and 1 had a solid fusion but chronic drainage. In 3 knees, the infection was cured but resection arthroplasties were required, and in 1 patient an amputation was needed as a result of an intraoperative vascular complication.

  9. Influence of Total Knee Arthroplasty on Patellar Kinematics and Patellofemoral Pressure.

    PubMed

    Tanikawa, Hidenori; Tada, Mitsunori; Harato, Kengo; Okuma, Kazunari; Nagura, Takeo

    2017-01-01

    Patellofemoral complications are one of the main problems after total knee arthroplasty (TKA). The design of the TKA component may affect the patellar biomechanics, which may be associated with this postoperative complication. The purpose of this study was to assess the influence of TKA and prosthesis designs on the patellar kinematics and patellofemoral pressure. Using fresh-frozen cadavers, we measured the patellofemoral pressure, patella offset, and patella tilt in the following 4 conditions: normal knee (patella replacement only), cruciate-retaining TKA, condylar-stabilizing TKA, and posterior-stabilized TKA. The patellofemoral pressure increased significantly after the cruciate-retaining TKA and condylar-stabilizing TKA compared with the normal knee. The patella offset in the normal knee decreased with increasing knee flexion angles, while the patella offset in the TKA knees did not change significantly through the full range of motion. The amount of lateral patella tilt in the normal knee was significantly larger than the TKA knees in the full range of motion. Although the femoral components are designed to reproduce an anatomical patellar tracking, the physiological patellar kinematics were not observed. Relatively high patellofemoral pressure and kinematic change after TKA may be associated with postoperative complications such as the anterior knee pain. Copyright © 2016 Elsevier Inc. All rights reserved.

  10. Expectations in patients with total knee arthroplasty.

    PubMed

    Tekin, Burcu; Unver, Bayram; Karatosun, Vasfi

    2012-01-01

    The primary objective of total knee arthroplasty (TKA) is to decrease pain and restore functional knee joint. Current hypotheses indicate higher knee flexion is required in terms of life style, culture and expectations in Eastern communities. Therefore, society-specific features related to life style and cultural habits are needed. The objective of this study was to investigate the expectations of patients undergoing TKA. The study included 131 patients (18 male, 113 female; mean age: 66.2 ± 8.3 years) who underwent cemented TKA due to knee osteoarthritis. All patients were operated by the same surgeon using the same implant and surgical technique. Patients were evaluated using the Hospital for Special Surgery (HSS) knee score, a 15-item clinical knee assessment questionnaire and the HSS knee arthroplasty expectation questionnaire. Mean HSS score for the right knee was 89.2 ± 10.5 and for the left knee was 89.6 ± 9.4. The two most expected outcomes were improvements in pain (99.2%) and gait (96.2%) and the two least expected outcomes were improvements in psychological well-being (22.9%) and communicative skills (35.1%). Expectations were not affected by education and working conditions. Patients' most expected outcomes were improvement in pain and restoration of function (gait, climbing stairs and no need of assistive devices), similar to Western and American communities.

  11. Stem cell application for osteoarthritis in the knee joint: A minireview.

    PubMed

    Uth, Kristin; Trifonov, Dimitar

    2014-11-26

    Knee osteoarthritis is a chronic, indolent disease that will affect an ever increasing number of patients, especially the elderly and the obese. It is characterized by degeneration of the cartilage substance inside the knee which leads to pain, stiffness and tenderness. By some estimations in 2030, only in the United States, this medical condition will burden 67 million people. While conventional treatments like physiotherapy or drugs offer temporary relief of clinical symptoms, restoration of normal cartilage function has been difficult to achieve. Moreover, in severe cases of knee osteoarthritis total knee replacement may be required. Total knee replacements come together with high effort and costs and are not always successful. The aim of this review is to outline the latest advances in stem cell therapy for knee osteoarthritis as well as highlight some of the advantages of stem cell therapy over traditional approaches aimed at restoration of cartilage function in the knee. In addition to the latest advances in the field, challenges associated with stem cell therapy regarding knee cartilage regeneration and chondrogenesis in vitro and in vivo are also outlined and analyzed. Furthermore, based on their critical assessment of the present academic literature the authors of this review share their vision about the future of stem cell applications in the treatment of knee osteoarthritis.

  12. [Knee-related Pain Problems during Pregnancy Correlate with an Increase in Body Weight. Results of a Prospective Study].

    PubMed

    Spahn, G; Lesser, A; Hofmann, G O; Schiele, R

    2015-10-01

    This study aimed to evaluate the incidence of knee pain or the intensification of knee-related problems during pregnancy. We hypothesised that the occurrence of knee problems correlates with an increase in body weight during pregnancy. A total of 326 women (30(th)-40(th) week of pregnancy) were involved in this study. At onset of the pregnancy, the patients were 29.4 [95% CI 28.8-29.9] years of age. We asked all patients retrospectively about their anthropometric data at the beginning of pregnancy. All patients provided information about former knee problems, knee problems occurring after onset of pregnancy or any increase in these problems. These knee patients were re-evaluated 6 weeks after childbirth. At follow-up, the patients were asked about their knee problems and about their body weight. At the beginning of pregnancy, the mean body weight was 68.0 kg (95% CI 64.4-69.6; range 41-117). The mean BMI of all patients was 24.5 kg/m² (25% CI 23.9-25.0; range 17.0-26.0). The absolute body weight increased by 13.8 kg (95% CI 13.2-1.5; range 3-38). A total of 24 patients (7.4%) reported new knee problems during pregnancy. 2 patients reported an increase in knee-related problems during pregnancy (0.6%). The incidence of knee-related problems (new cases and increase of problems n=26) was 26/326 or 7.6/100 pregnancies. In patients without knee problems, the pregnancy-related increase in the BMI (ΔBMI) was 4.8 kg/m² (95% CI 4.6-5.1, range 1.1-14.1). In cases with incident knee problems, the ΔBMI was 5.9 kg/m² (95% CI 4.9-6.9, range 2.1-11.8). The increase in body weight (Δbody weight) in patients without knee problems was 13.5 kg (95% CI 12.9-14.2, range 3-38). Patients with incident knee pain experienced a Δbody weight of 16.8 kg (95% CI 13.9-19.4, range 6-35). The differences in ΔBMI and Δbody weight were significant (p=0.009). A Δbody weight >20 kg was a significant risk factor for pregnancy-related knee pain significant risk factor pregnancy related pain. A total of 23 incident cases (92%) underwent a follow-up interview 6 weeks after parturition. At this time, a total of 6 patients (26.1%) had not experienced further knee problems, whereas persistent knee problems were reported in the remaining patients (73.9%). Patients without any knee complaints [body weight 72.5 kg (CI 95% 60.9-83.9)] tended to have a lower body weight at follow-up than patients with persistent knee pain [85.5 kg (CI 95% 71.8-99.1), p=0.162]. There is a body weight-associated increase in the incidence of functional knee pain in pregnant women. In about one-third of the cases, knee problems persist after pregnancy and are associated with a residual increase in body weight. Thus, we conclude that body weight is a potential risk factor for functional knee pain. © Georg Thieme Verlag KG Stuttgart · New York.

  13. Factors affecting the achievement of Japanese-style deep knee flexion after total knee arthroplasty using posterior-stabilized prosthesis with high-flex knee design.

    PubMed

    Niki, Yasuo; Takeda, Yuki; Harato, Kengo; Suda, Yasunori

    2015-11-01

    Achievement of very deep knee flexion after total knee arthroplasty (TKA) can play a critical role in the satisfaction of patients who demand a floor-sitting lifestyle and engage in high-flexion daily activities (e.g., seiza-sitting). Seiza-sitting is characterized by the knees flexed >145º and feet turned sole upwards underneath the buttocks with the tibia internally rotated. The present study investigated factors affecting the achievement of seiza-sitting after TKA using posterior-stabilized total knee prosthesis with high-flex knee design. Subjects comprised 32 patients who underwent TKA with high-flex knee prosthesis and achieved seiza-sitting (knee flexion >145º) postoperatively. Another 32 patients served as controls who were capable of knee flexion >145º preoperatively, but failed to achieve seiza-sitting postoperatively. Accuracy of femoral and tibial component positions was assessed in terms of deviation from the ideal position using a two-dimensional to three-dimensional matching technique. Accuracies of the component position, posterior condylar offset ratio and intraoperative gap length were compared between the two groups. The proportion of patients with >3º internally rotated tibial component was significantly higher in patients who failed at seiza-sitting (41 %) than among patients who achieved it (13 %, p = 0.021). Comparison of intraoperative gap length between patient groups revealed that gap length at 135º flexion was significantly larger in patients who achieved seiza-sitting (4.2 ± 0.4 mm) than in patients who failed at it (2.7 ± 0.4 mm, p = 0.007). Conversely, no significant differences in gap inclination were seen between the groups. From the perspective of surgical factors, accurate implant positioning, particularly rotational alignment of the tibial component, and maintenance of a sufficient joint gap at 135º flexion appear to represent critical factors for achieving >145º of deep knee flexion after TKA.

  14. Knee contact forces and lower extremity support moments during running in young individuals post-partial meniscectomy.

    PubMed

    Willy, R W; Bigelow, M A; Kolesar, A; Willson, J D; Thomas, J S

    2017-01-01

    While partial meniscectomy results in a compromised tibiofemoral joint, little is known regarding tibiofemoral joint loading during running in individuals who are post-partial meniscectomy. It was hypothesized that individuals post-partial meniscectomy would run with a greater hip support moment, yielding reduced peak knee extension moments and reduced tibiofemoral joint contact forces. 3-D Treadmill running mechanics were evaluated in 23 athletic individuals post-partial meniscectomy (37.5 ± 19.0 months post-partial meniscectomy) and 23 matched controls. Bilateral hip, knee and ankle contributions to the total support moment and the peak knee extension moment were calculated. A musculoskeletal model estimated peak and impulse tibiofemoral joint contact forces. Knee function was quantified with the Knee injury and Osteoarthritis Outcome Score (KOOS). During running, the partial meniscectomy group had a greater hip support moment (p = 0.002) and a reduced knee support moment (p < 0.001) relative to the total support moment. This movement pattern was associated with a 14.5 % reduction (p = 0.019) in the peak knee extension moment. Despite these differences, there were no significant group differences in peak or impulse tibiofemoral joint contact forces. Lower KOOS Quality of Life scores were associated with greater hip support moment (p = 0.004, r = -0.58), reduced knee support moment (p = 0.006, r = 0.55) and reduced peak knee extension moment (p = 0.01, r = 0.52). Disordered running mechanics are present long term post-partial meniscectomy. A coordination strategy that shifts a proportion of the total support moment away from the knee to the hip reduces the peak knee extension moment, but does not equate to reduced tibiofemoral joint contact forces during running in individuals post-partial meniscectomy. III.

  15. No Exacerbation of Knee Joint Pain and Effusion Following Preoperative Progressive Resistance Training in Patients Scheduled for Total Knee Arthroplasty: Secondary Analyses From a Randomized Controlled Trial.

    PubMed

    Skoffer, Birgit; Dalgas, Ulrik; Maribo, Thomas; Søballe, Kjeld; Mechlenburg, Inger

    2017-11-09

    Preoperative progressive resistance training (PRT) is controversial in patients scheduled for total knee arthroplasty (TKA), because of the concern that it may exacerbate knee joint pain and effusion. To examine whether preoperative PRT initiated 5 weeks prior to TKA would exacerbate pain and knee effusion, and would allow a progressively increased training load throughout the training period that would subsequently increase muscle strength. Secondary analyses from a randomized controlled trial. University Hospital and a Regional Hospital. A total of 30 patients who were scheduled for TKA due to osteoarthritis and assigned as the intervention group. Patients underwent unilateral PRT (3 sessions per week). Exercise loading was 12 repetitions maximum (RM) with progression toward 8 RM. The training program consisted of 6 exercises performed unilaterally. Before and after each training session, knee joint pain was rated on an 11-point scale, effusion was assessed by measuring the knee joint circumference, and training load was recorded. The first and last training sessions were initiated by 1 RM testing of unilateral leg press, unilateral knee extension, and unilateral knee flexion. The median pain change score from before to after each training session was 0 at all training sessions. The average increase in knee joint effusion across the 12 training sessions was a mean 0.16 cm ± 0.23 cm. No consistent increase in knee joint effusion after training sessions during the training period was found (P = .21). Training load generally increased, and maximal muscle strength improved as follows: unilateral leg press: 18% ± 30% (P = .03); unilateral knee extension: 81% ± 156% (P < .001); and unilateral knee flexion: 53% ± 57% (P < .001). PRT of the affected leg initiated shortly before TKA does not exacerbate knee joint pain and effusion, despite a substantial progression in loading and increased muscle strength. Concerns for side effects such as pain and effusion after PRT seem unfounded. To be determined. Copyright © 2017. Published by Elsevier Inc.

  16. Modelling and Analysis on Biomechanical Dynamic Characteristics of Knee Flexion Movement under Squatting

    PubMed Central

    Wang, Jianping; Tao, Kun; Li, Huanyi; Wang, Chengtao

    2014-01-01

    The model of three-dimensional (3D) geometric knee was built, which included femoral-tibial, patellofemoral articulations and the bone and soft tissues. Dynamic finite element (FE) model of knee was developed to simulate both the kinematics and the internal stresses during knee flexion. The biomechanical experimental system of knee was built to simulate knee squatting using cadaver knees. The flexion motion and dynamic contact characteristics of knee were analyzed, and verified by comparing with the data from in vitro experiment. The results showed that the established dynamic FE models of knee are capable of predicting kinematics and the contact stresses during flexion, and could be an efficient tool for the analysis of total knee replacement (TKR) and knee prosthesis design. PMID:25013852

  17. Pre-operative patient education is associated with decreased risk of arthrofibrosis after total knee arthroplasty: a case control study.

    PubMed

    Livbjerg, Anna Emilie; Froekjaer, Sara; Simonsen, Ole; Rathleff, Michael S

    2013-09-01

    The purpose was to investigate risk factors for postoperative stiffness and long-term outcome following manipulation under anaesthesia (MUA). In one of the five Danish regions, all patients in a 4-year period who received MUA following total knee arthroplasty (N=36) were included in two case-control studies. Data on potential risk factors were extracted from the Danish Knee arthroplasty Register and from a postal questionnaire including long-term outcome measures regarding pain, function and quality of life (Oxford Knee Score and EQ-5D). Previous knee surgery and a high preoperative Knee Society Function Score were significant risk factors, whereas attending a preoperative information meeting was associated with a significantly decreased risk of postoperative stiffness requiring MUA (P<0.001). The long-term results following MUA (1-5 years) were equivalent to patients without postoperative stiffness. Copyright © 2013 Elsevier Inc. All rights reserved.

  18. Vascularised knee joint transplantation in man: the first two years experience.

    PubMed

    Kirschner, M H; Brauns, L; Gonschorek, O; Bühren, V; Hofmann, G O

    2000-04-01

    To describe our early experience with a new technique for restoring destroyed knee joints to give reasonable functional results. Observational clinical trial. Level-1-Trauma centre, Germany. 5 patients with large bone defects of the knee and loss of the extensor apparatus caused either by serious injury alone, or infection after serious injury. Transplantation of fresh and perfused knee joints with a vascular pedicle from multiorgan donors under immunosuppression. Ability to walk, need to remove one transplanted joint. Four patients are able to walk, the range of movement being from 50 degrees-120 degrees. The first patient additionally had to be provided with a total knee joint arthroplasty. In the third patient the graft became infected and had to be removed. She finally had an arthrodesis and bone lengthening by the Ilizarov technique. Transplantation of the knee joint may be an alternative to bone lengthening or amputation for patients with total loss of the extensor apparatus.

  19. Early clinical results of a high-flexion, posterior-stabilized, mobile-bearing total knee arthroplasty: a US investigational device exemption trial.

    PubMed

    Scuderi, Giles R; Hedden, David R; Maltry, John A; Traina, Steven M; Sheinkop, Mitchell B; Hartzband, Mark A

    2012-03-01

    Between May 2001 and June 2004, 388 total knee arthroplasty cases were enrolled in a prospective, randomized, multicenter investigational device exemption trial. Patients received either the investigational high-flexion mobile-bearing knee or a fixed-bearing control. At 2 to 4 years of follow-up, results in 293 patients with degenerative joint disease were compared using Knee Society Assessment and Function scores, radiographic results, complications analysis, and survival estimates. The mobile-bearing and fixed-bearing groups demonstrated similar, significant improvement over preoperative assessments in Knee Scores, maximum flexion, and range of motion. One mobile-bearing arthroplasty required revision. Radiographic results were unremarkable, and implant-related complications were rare in both groups. At this early follow-up, the investigational high-flexion mobile-bearing knee and its fixed-bearing counterpart demonstrated comparable, effective performance. Copyright © 2012 Elsevier Inc. All rights reserved.

  20. [Generalised Form of Synovial Chondromatosis of the Knee Joint].

    PubMed

    Vališ, P; Vyskočil, R

    2016-01-01

    This study describes a diagnostic and therapeutic algorithm in a 53-year-old male patient who was diagnosed with a synovial chondromatosis of the knee joint extending to the popliteal fossa and soft tissues around the knee. Because of the presence of massive nodules, the patient was indicated for total synovectomy, with removal of pathologically changed cartilaginous tissue, performed by combined anterior and posterior approaches to the knee joint. Despite complete removal of the synovium and loose cartilage bodies and the patient's pain relief in the post-operative time, three years after the operation new problems appeared. Magnetic resonance imaging (MRI) confirmed a relapse of synovial chondromatosis and the patient was indicated for revision surgery of the knee joint. The results of physical examination and MRI scans, and intra-operative findings in the patient are reported. synovial chondromatosis, total synovectomy, direct anterior and posterior approaches to the knee joint.

  1. Posterior medial meniscus detachment: a unique type of medial meniscal tear.

    PubMed

    Rubinstein, Richard A; DeHaan, Alex; Baldwin, James L

    2009-10-01

    Patients with posterior medial meniscal detachment, as determined at knee arthroscopy, were evaluated retrospectively. Mean follow-up was 5.3 years for 8 men and 20 women (30 knees; mean age, 57 years). Most patients had acute onset of pain with a minor specific incident. Seventeen patients were obese, 9 were overweight, and 2 were normal. Eleven of 22 magnetic resonance imaging evaluations detected a tear at the site of the posterior medial meniscus root. Nine of 16 bone scan evaluations showed moderate uptake medially. Arthroscopic treatment included partial medial meniscectomy or meniscal repair. Twelve knees (40%) showed significant progression of arthritis. Of the 7 patients with severe arthritic knees, 5 have subsequently undergone total knee arthroplasty, 1 is considering total knee arthroplasty, and the other has minimal symptoms. Patients should be counseled about the clinical course of posterior medial meniscus detachment and its potential for progressive arthritis in the joint.

  2. Aspirin or Rivaroxaban for VTE Prophylaxis after Hip or Knee Arthroplasty.

    PubMed

    Anderson, David R; Dunbar, Michael; Murnaghan, John; Kahn, Susan R; Gross, Peter; Forsythe, Michael; Pelet, Stephane; Fisher, William; Belzile, Etienne; Dolan, Sean; Crowther, Mark; Bohm, Eric; MacDonald, Steven J; Gofton, Wade; Kim, Paul; Zukor, David; Pleasance, Susan; Andreou, Pantelis; Doucette, Steve; Theriault, Chris; Abianui, Abongnwen; Carrier, Marc; Kovacs, Michael J; Rodger, Marc A; Coyle, Doug; Wells, Philip S; Vendittoli, Pascal-Andre

    2018-02-22

    Clinical trials and meta-analyses have suggested that aspirin may be effective for the prevention of venous thromboembolism (proximal deep-vein thrombosis or pulmonary embolism) after total hip or total knee arthroplasty, but comparisons with direct oral anticoagulants are lacking for prophylaxis beyond hospital discharge. We performed a multicenter, double-blind, randomized, controlled trial involving patients who were undergoing total hip or knee arthroplasty. All the patients received once-daily oral rivaroxaban (10 mg) until postoperative day 5 and then were randomly assigned to continue rivaroxaban or switch to aspirin (81 mg daily) for an additional 9 days after total knee arthroplasty or for 30 days after total hip arthroplasty. Patients were followed for 90 days for symptomatic venous thromboembolism (the primary effectiveness outcome) and bleeding complications, including major or clinically relevant nonmajor bleeding (the primary safety outcome). A total of 3424 patients (1804 undergoing total hip arthroplasty and 1620 undergoing total knee arthroplasty) were enrolled in the trial. Venous thromboembolism occurred in 11 of 1707 patients (0.64%) in the aspirin group and in 12 of 1717 patients (0.70%) in the rivaroxaban group (difference, 0.06 percentage points; 95% confidence interval [CI], -0.55 to 0.66; P<0.001 for noninferiority and P=0.84 for superiority). Major bleeding complications occurred in 8 patients (0.47%) in the aspirin group and in 5 (0.29%) in the rivaroxaban group (difference, 0.18 percentage points; 95% CI, -0.65 to 0.29; P=0.42). Clinically important bleeding occurred in 22 patients (1.29%) in the aspirin group and in 17 (0.99%) in the rivaroxaban group (difference, 0.30 percentage points; 95% CI, -1.07 to 0.47; P=0.43). Among patients who received 5 days of rivaroxaban prophylaxis after total hip or total knee arthroplasty, extended prophylaxis with aspirin was not significantly different from rivaroxaban in the prevention of symptomatic venous thromboembolism. (Funded by the Canadian Institutes of Health Research; ClinicalTrials.gov number, NCT01720108 .).

  3. The Impact of Mechanical and Restricted Kinematic Alignment on Knee Anatomy in Total Knee Arthroplasty.

    PubMed

    Almaawi, Abdulaziz M; Hutt, Jonathan R B; Masse, Vincent; Lavigne, Martin; Vendittoli, Pascal-Andre

    2017-07-01

    Total knee arthroplasty (TKA), aiming at neutral mechanical alignment (MA), inevitably modifies the patient's native knee anatomy. Another option is kinematic alignment (KA), which aims to restore the original anatomy of the knee. The aim of this study was to evaluate the variations in lower limb anatomy of a patient population scheduled for TKA, and to assess the use of a restricted KA TKA protocol and compare the resulting anatomic modifications with the standard MA technique. A total of 4884 knee computed tomography scans were analyzed from a database of patients undergoing TKA with patient-specific instrumentation. The lateral distal femoral angle (LDFA), medial proximal tibial angle (MPTA), and hip-knee-ankle angle (HKA) were measured. Bone resections were compared using a standard MA and a restricted KA aiming for independent tibial and femoral cuts of maximum ±5° deviation from the coronal mechanical axis and a resulting overall coronal HKA within ±3° of neutral. The mean preoperative MPTA was 2.9° varus, LDFA was 2.7° valgus, and overall HKA was 0.1° varus. Using our protocol, 2475 knees (51%) could have undergone KA without adjustment. To include 4062 cases (83%), mean corrections of 0.5° for MPTA and 0.3° for LDFA were needed, significantly less than with MA (3.3° for MPTA and 3.2° for LDFA; P < .001). The range of knee anatomy in patients scheduled for TKA is wide. MA leads to greater modifications of knee joint anatomy. To avoid reproducing extreme anatomy, the proposed restricted KA protocol provides an interesting hybrid option between MA and true KA. Copyright © 2017 Elsevier Inc. All rights reserved.

  4. A Comparison of 2 Tibial Inserts of Different Constraint for Cruciate-Retaining Primary Total Knee Arthroplasty: An Additional Tool for Balancing the Posterior Cruciate Ligament.

    PubMed

    Emerson, Roger H; Barrington, John W; Olugbode, Seun A; Alnachoukati, Omar K

    2016-02-01

    Frequently, a normal posterior-cruciate ligament (PCL) is removed at the surgeon's discretion, converting the normal 4-ligament knee to a 2-ligament knee, thus eliminating the need to balance all 4 ligaments. The development of modular tibial components has led to the availability of differing polyethylene inserts that permit adjustment to the flexion gap independent of the extension gap, permitting PCL balancing not previously available. The purpose of this study is to analyze a specific cruciate-retaining (CR) prosthesis which has 2 polyethylene inserts intended for CR knee use. Between February 2004 and February 2013, the senior author (R.H.E.) has performed 930 total knee arthroplasties using the CR flat insert and 424 knees using the CR lipped insert. The inserts were selected during surgery, based on the assessed tension and function of the PCL. The patients were followed up as part of a prospective total joint program with the Knee Society clinical scoring, range of motion, complications, revisions, preoperative coronal deformity, gender, body mass index, and status of the anterior-cruciate ligament intraoperatively. The average Knee Score was 92.4 for the flat group and 92.1 for the lipped group. Average knee flexion was 116.2° for the flat group and 114.4° for the lipped group (P=.2). Average knee extension (flexion deformity) was 2.1° for the flat group and 0.9° for the lipped group The results reported here show that clinical outcomes and survivorship were no different for either insert option, leading to indirect evidence that appropriate soft tissue balance had been achieved. Published by Elsevier Inc.

  5. Effect of knee osteoarthritis on the perception of quality of life in Venezuelan patients.

    PubMed

    Chacón, José G; González, Nancy E; Véliz, Aleida; Losada, Benito R; Paul, Hernando; Santiago, Luís G; Antúnez, Ana; Finol, Yelitza; González, María E; Granados, Isabel; Maldonado, Irama; Maldonado, Teolinda; Marín, Francisco; Zambrano, Gisela; Rodríguez, Martín A

    2004-06-15

    To measure the perception of quality of life in Venezuelan patients with knee osteoarthritis and to identify those variables that may influence it. A multicenter, cross-sectional study of 126 mestizo patients with knee osteoarthritis recruited from 8 rheumatology centers in Venezuela. We used a Spanish-translated version of the Arthritis Impact Measurement Scales (AIMS), as adapted in Venezuela. One-way analysis of variance was used to compare the AIMS mean total score among subgroups of knee pain, anatomic stage, and socioeconomic status (SES); a post-hoc test was performed to identify significant intragroup differences. Pearson's correlation coefficient was used to examine correlations between age, body mass index (BMI), disease duration, knee pain, and AIMS score. Associations between radiologic stage, SES, and AIMS scores were examined using Spearman's rank correlation. Multiple regression analysis was used to estimate predictor factors of AIMS scores. A significant correlation was found between total AIMS scores and knee pain, age, and socioeconomic status, but not with BMI, disease duration, or anatomic stage. Patients with severe knee pain differed from those with mild and moderate pain, and the highest AIMS mean total score was seen in patients within the severe knee pain subset. Patients in the highest socioeconomic levels differed from those within lowest categories. Patients classified as being at the levels of relative and critical poverty showed the highest AIMS scores. Multiple regression analysis showed that knee pain was the only variable that exerted an independent effect on the quality of life in our patients. The perception of quality of life is negatively affected by increasing levels of joint pain, old age, and low socioeconomic status in Venezuelan patients with knee osteoarthritis. Our study supports the need for an early and vigorous approach to treat pain in this group of patients.

  6. Biomechanical and Performance Differences Between Female Soccer Athletes in National Collegiate Athletic Association Divisions I and III

    PubMed Central

    Smith, Rose; Ford, Kevin R; Myer, Gregory D; Holleran, Adam; Treadway, Erin; Hewett, Timothy E

    2007-01-01

    Context: The recent increase in women's varsity soccer participation has been accompanied by a lower extremity injury rate that is 2 to 6 times that of their male counterparts. Objective: To define the differences between lower extremity biomechanics (knee abduction and knee flexion measures) and performance (maximal vertical jump height) between National Collegiate Athletic Association Division I and III female soccer athletes during a drop vertical jump. Design: Mixed 2 × 2 design. Setting: Research laboratory. Patients or Other Participants: Thirty-four female collegiate soccer players (Division I: n = 19; Division III: n = 15) participated in the study. The groups were similar in height and mass. Intervention(s): Each subject performed a maximal vertical jump, followed by 3 drop vertical jumps. Main Outcome Measure(s): Kinematics (knee abduction and flexion angles) and kinetics (knee abduction and flexion moments) were measured with a motion analysis system and 2 force platforms during the drop vertical jumps. Results: Knee abduction angular range of motion and knee abduction external moments were not different between groups (P > .05). However, Division I athletes demonstrated decreased knee flexion range of motion (P = .038) and greater peak external knee flexion moment (P = .009) compared with Division III athletes. Division I athletes demonstrated increased vertical jump height compared with Division III (P = .008). Conclusions: Division I athletes demonstrated different sagittal-plane mechanics than Division III athletes, which may facilitate improved performance. The similarities in anterior cruciate ligament injury risk factors (knee abduction torques and angles) may correlate with the consistent incidence of anterior cruciate ligament injury across divisions. PMID:18174935

  7. Effect of transcutaneous electrical nerve stimulation for pain control after total knee arthroplasty: A systematic review and meta-analysis.

    PubMed

    Zhu, Yongjun; Feng, Yuxing; Peng, Lihua

    2017-11-21

    Transcutaneous electrical nerve stimulation is a possible adjunctive therapy to pharmacological treatment for controlling pain after total knee arthroplasty. However, the results are controversial. A systematic review and meta-analysis was conducted to explore the effect of transcutaneous electrical nerve stimulation on patients with total knee arthroplasty. PubMed, Embase, Web of Science, EBSCO, and Cochrane Library databases were searched systematically. Randomized controlled trials assessing the effect of transcutaneous electrical nerve stimulation on patients with total knee arthroplasty were included. Two investigators independently searched articles, extracted data, and assessed the quality of included studies. Primary outcome was visual analogue scale (VAS) score over a period of 24 h. Meta-analysis was performed using a random-effect model. Six randomized controlled trials involving 529 patients were included in the meta-analysis. Overall, compared with control intervention, transcutaneous electrical nerve stimulation supplementation intervention was found to significantly reduce VAS scores and total postoperative morphine dose over a period of 24 h, and to improve active range of knee motion (standard mean difference (SMD) = 0.37; 95% confidence interval (95% CI) = 0.06-0.68; p = 0.02), but had no effect on VAS scores at 2 weeks (SMD = 0.20; 95% CI = -0.07 to 0.48; p = 0.15). Compared with control intervention, transcutaneous electrical nerve stimulation supplementation intervention was found to significantly reduce pain and morphine requirement over a period of 24 h and to promote functional recovery in patients who have undergone total knee arthroplasty.

  8. [Comparison of therapeutic effects between patella replacement and patella osteotomy in total knee arthroplasty: a case-control study].

    PubMed

    Tang, Xiao-Bo; Dong, Pei-Long; Wang, Jian

    2014-04-01

    To compare therapeutic effects between patella replacement and patella osteotomy in total knee arthroplasty. From April 2004 to April 2011, 52 patients (54 knees) were enrolled in the clinical trail of total knee arthroplasty, who received patella replacement (24 knees, including 13 males and 11 females,ranging in age from 53 to 78 years old or patella osteotomy (30 knees,including 16 males and 12 females,ranging in age from 55 to 79 years old. The average follow-up period was 56 months,ranging from 20 to 80 months. The American HSS Score for knee, the Feller score for patella, range of motion (ROM) for knee, patient satisfaction and complications related to the patella were used to evaluate therapeutic effects. In the patella replacement group,the preoperative and final follow-up HSS scores of patients were 38.4 +/- 8.2 and 91.2 +/- 8.6 respectively; Feller scores were 13.6 +/- 6.2 and 25.2 +/- 4.2; scores of anterior knee pain were 3.9 +/- 3.2 and 11.2 +/- 3.7; ROM were (78 +/- 26) degrees and(108 +/- 18) degrees. In the patella osteotomy group,the preoperative and final follow-up HSS scores of patients were 39.5 +/- 8.4 and 91.0 +/- 8.5 respectively;Feller scores were 13.4 +/- 6.5 and 25.6 +/- 4.0; scores of anterior knee pain were 3.7 +/- 3.1 and 11.3 +/- 3.6; ROM were (76 +/- 27) degrees and (110 +/- 19) degrees. In the patella replacement group,patient's satisfaction was 91%, and complication related to the patella was 16.7%; in the patella osteotomy group, patient's satisfaction was 89%, and complications related to the patella was 10.0%. There were no statistically significant differeneces in final follow-up HSS scores, Feller scores, scores of anterior knee pain and ROM between the two groups. However,there was no significant difference of patient's satisfaction between them. There was statistically significant differenece of patella-related complications between the two groups, and the complication rate in the patella replacement group was higher than that in the patella osteotomy group. Total knee arthroplasty with patella replacement or patella osteotomy dramatically relieves pain and improves the knee function. Patella-related complications are associated with its treatment methods, but post-operative anterior knee pain and patient's satisfaction are not related to treatment methods of the patella.

  9. Biomechanical Evaluation of a Prototype Foot/Ankle Prosthesis

    PubMed Central

    Quesada, P. M.; Pitkin, M.; Colvin, J.

    2016-01-01

    In this paper, we report on our pilot evaluation of a prototype foot/ankle prosthesis. This prototype has been designed and fabricated with the intention of providing decreased ankle joint stiffness during the middle portion of the stance phase of gait, and increased (i.e., more normal) knee range of motion during stance. Our evaluation involved fitting the existing prototype foot/ankle prosthesis, as well as a traditional solid ankle cushioned heel (SACH) foot, to an otherwise healthy volunteer with a below-knee (BK) amputation. We measured this individual’s lower extremity joint kinematics and kinetics during walking using a video motion analysis system and force platform. These measurements permitted direct comparison of prosthetic ankle joint stiffness and involved side knee joint motion, as well as prosthetic ankle joint moment and power. PMID:10779119

  10. Are the Kinematics of the Knee Joint Altered during the Loading Response Phase of Gait in Individuals with Concurrent Knee Osteoarthritis and Complaints of Joint Instability? A Dynamic Stereo X-ray Study

    PubMed Central

    Farrokhi, Shawn; Tashman, Scott; Gil, Alexandra B.; Klatt, Brian A.; Fitzgerald, G. Kelley

    2011-01-01

    Background Joint instability has been suggested as a risk factor for knee osteoarthritis and a cause of significant functional declines in those with symptomatic disease. However, the relationship between altered knee joint mechanics and self-reports of instability in individuals with knee osteoarthritis remains unclear. Methods Fourteen subjects with knee osteoarthritis and complaints of joint instability and 12 control volunteers with no history of knee disease were recruited for this study. Dynamic stereo X-ray technology was used to assess the three-dimensional kinematics of the knee joint during the loading response phase of gait. Findings Individuals with concurrent knee osteoarthritis and joint instability demonstrated significantly reduced flexion and internal/external rotation knee motion excursions during the loading response phase of gait (P < 0.01), while the total abduction/adduction range of motion was increased (P < 0.05). In addition, the coronal and transverse plane alignment of the knee joint at initial contact was significantly different (P < 0.05) for individuals with concurrent knee osteoarthritis and joint instability. However, the anteroposterior and mediolateral tibiofemoral joint positions at initial contact and the corresponding total joint translations were similar between groups during the loading phase of gait. Interpretations The rotational patterns of tibiofemoral joint motion and joint alignments reported for individuals with concurrent knee osteoarthritis and joint instability are consistent with those previously established for individuals with knee osteoarthritis. Furthermore, the findings of similar translatory tibiofemoral motion between groups suggest that self-reports of episodic joint instability in individuals with knee osteoarthritis may not necessarily be associated with adaptive alterations in joint arthrokinematics. PMID:22071429

  11. Are the kinematics of the knee joint altered during the loading response phase of gait in individuals with concurrent knee osteoarthritis and complaints of joint instability? A dynamic stereo X-ray study.

    PubMed

    Farrokhi, Shawn; Tashman, Scott; Gil, Alexandra B; Klatt, Brian A; Fitzgerald, G Kelley

    2012-05-01

    Joint instability has been suggested as a risk factor for knee osteoarthritis and a cause of significant functional decline in those with symptomatic disease. However, the relationship between altered knee joint mechanics and self-reports of instability in individuals with knee osteoarthritis remains unclear. Fourteen subjects with knee osteoarthritis and complaints of joint instability and 12 control volunteers with no history of knee disease were recruited for this study. Dynamic stereo X-ray technology was used to assess the three-dimensional kinematics of the knee joint during the loading response phase of gait. Individuals with concurrent knee osteoarthritis and joint instability demonstrated significantly reduced flexion and internal/external rotation knee motion excursions during the loading response phase of gait (P<0.01), while the total abduction/adduction range of motion was increased (P<0.05). In addition, the coronal and transverse plane alignment of the knee joint at initial contact was significantly different (P<0.05) for individuals with concurrent knee osteoarthritis and joint instability. However, the anteroposterior and mediolateral tibiofemoral joint positions at initial contact and the corresponding total joint translations were similar between groups during the loading phase of gait. The rotational patterns of tibiofemoral joint motion and joint alignments reported for individuals with concurrent knee osteoarthritis and joint instability are consistent with those previously established for individuals with knee osteoarthritis. Furthermore, the findings of similar translatory tibiofemoral motion between groups suggest that self-reports of episodic joint instability in individuals with knee osteoarthritis may not necessarily be associated with adaptive alterations in joint arthrokinematics. Copyright © 2011 Elsevier Ltd. All rights reserved.

  12. Whole-body vibration does not influence knee joint neuromuscular function or proprioception.

    PubMed

    Hannah, R; Minshull, C; Folland, J P

    2013-02-01

    This study examined the acute effects of whole-body vibration (WBV) on knee joint position sense and indices of neuromuscular function, specifically strength, electromechanical delay and the rate of force development. Electromyography and electrically evoked contractions were used to investigate neural and contractile responses to WBV. Fourteen healthy males completed two treatment conditions on separate occasions: (1) 5 × 1 min of unilateral isometric squat exercise on a synchronous vibrating platform [30 Hz, 4 mm peak-to-peak amplitude] (WBV) and (2) a control condition (CON) of the same exercise without WBV. Knee joint position sense (joint angle replication task) and quadriceps neuromuscular function were assessed pre-, immediately-post and 1 h post-exercise. During maximum voluntary knee extensions, the peak force (PF(V)), electromechanical delay (EMD(V)), rate of force development (RFD(V)) and EMG of the quadriceps were measured. Twitch contractions of the knee extensors were electrically evoked to assess EMD(E) and RFD(E). The results showed no influence of WBV on knee joint position, EMD(V), PF(V) and RFD(V) during the initial 50, 100 or 150 ms of contraction. Similarly, electrically evoked neuromuscular function and neural activation remained unchanged following the vibration exercise. A single session of unilateral WBV did not influence any indices of thigh muscle neuromuscular performance or knee joint proprioception. © 2011 John Wiley & Sons A/S.

  13. Effects of a Prophylactic Knee Sleeve on Anterior Cruciate Ligament Loading During Sport Specific Movements.

    PubMed

    Sinclair, Jonathan; Taylor, Paul John

    2017-07-17

    Prophylactic knee bracing is extensively utilized in athletic populations, to reduce the high risk from knee injuries, but their role in the attenuation of anterior cruciate ligament (ACL) pathologies is not well understood. The aim of the current investigation was to investigate the effects of a prophylactic knee sleeve on ACL loading parameters linked to the aetiology of injury in recreational athletes. Laboratory. Repeated measures. Thirteen healthy male recreational athletes. Intervention Participants performed run, cut and single leg hop movements under two conditions; prophylactic knee sleeve and no-sleeve. Biomechanical data was captured using an eight-camera 3D motion capture system and a force platform. Peak ACL force, average ACL load rate and instantaneous ACL load rate were quantified using a musculoskeletal modelling approach. The results showed that both average and instantaneous ACL load rates were significantly reduced when wearing the knee sleeve in the hop (sleeve = 612.45/ 1286.39N/kg/s & no-sleeve = 743.91/ 1471.42 N/kg/s) and cut (sleeve = 222.55/ 1058.02 N/kg/s & no-sleeve = 377.38/ 1183.01 N/kg/s) movements. Given the biomechanical association between ACL loading and the aetiology of ACL injuries, it is proposed that athletes may be able to attenuate their risk from injury during cut and hop movements through utilization of a prophylactic knee sleeve.

  14. Secondary patella resurfacing in painful non-resurfaced total knee arthroplasties : A study of survival and clinical outcome from the Norwegian Arthroplasty Register (1994-2011).

    PubMed

    Leta, Tesfaye H; Lygre, Stein Håkon L; Skredderstuen, Arne; Hallan, Geir; Gjertsen, Jan-Erik; Rokne, Berit; Furnes, Ove

    2016-04-01

    In Norway, 19 % of revisions of non-resurfaced total knee arthroplasties done for knee pain between 1994 and 2011 were Secondary Patella Resurfacing (SPR). It is, however, unclear whether SPR actually resolves the pain. The aim was to investigate prostheses survival and clinical outcomes following SPR. A total of 308 knees (301 patients) with SPR were used to assess implant survival, and a sub-cohort (n = 114 out of 301 patients) with Patient Reported Outcome Measures (PROMs) data were used to assess the clinical outcomes. The EuroQol (EQ-5D), the Knee Injury and Osteoarthritis Outcome Score, and Visual Analogue Scales on satisfaction and pain were used to collect PROM data. Outcomes were analysed by Kaplan-Meier, Cox regression, and multiple linear regression. The five- and ten-year Kaplan-Meier survival percentages were 91 % and 87 %, respectively. Overall, 35 knees were re-revised at a median follow-up of eight years and pain alone (10 knees) was the main cause of re-revision. Younger patients (<60 years) had nearly nine times higher risk of re-revision compared to older patients (>70 years) (RR = 8.6; p < 0.001). Mean EQ-5D index score had improved from 0.41 (SD 0.21) preoperative to 0.56 (SD 0.25) postoperative following SPR. A total of 63 % of patients with PROM data were satisfied with the outcomes of SPR. The long-term prostheses survival following SPR was satisfactory, although not as good as for primary knee replacement. Patients' health related quality of life improved significantly following SPR. Still, more than a third of patients with PROMs data were dissatisfied with the outcomes of the SPR procedure.

  15. Total knee arthroplasty in a pseudoachondroplastic dwarfism patient with bilateral patellar dislocation.

    PubMed

    Oh, Kwang-Jun; Yoon, Jung-Ro; Yang, Jae-Hyuk

    2013-01-01

    Late presentation of congenital patellar dislocation with advanced osteoarthritis is rare. This article presents a case of a 59-year-old man with underlying pseudoachondroplastic dwarfism. Advanced osteoarthritis due to bilateral neglected congenital patellar dislocation was treated with total knee arthroplasty without patella relocation surgery. Two years later, the patient had an improvement in Knee Society scores, painless function, and stability. Copyright © 2012 Elsevier B.V. All rights reserved.

  16. Relationship between leg extensor muscle strength and knee joint loading during gait before and after total knee arthroplasty.

    PubMed

    Vahtrik, Doris; Gapeyeva, Helena; Ereline, Jaan; Pääsuke, Mati

    2014-01-01

    The aim of the present study was to evaluate an isometric maximal voluntary contraction (MVC) force of the leg extensor muscles and its relationship with knee joint loading during gait prior and after total knee arthroplasty (TKA). Custom-made dynamometer was used to assess an isometric MVC force of the leg extensor muscles and 3-D motion analysis system was used to evaluate the knee joint loading during gait in 13 female patients (aged 49-68 years) with knee osteoarthritis. Patients were evaluated one day before, and three and six months following TKA in the operated and non-operated leg. Six months after TKA, MVC force of the leg extensor muscles for the operated leg did not differ significantly as compared to the preoperative level, whereas it remained significantly lower for the non-operated leg and controls. The knee flexion moment and the knee joint power during mid stance of gait was improved six months after TKA, remaining significantly lowered compared with controls. Negative moderate correlation between leg extensor muscles strength and knee joint loading for the operated leg during mid stance was noted three months after TKA. The correlation analysis indicates that due to weak leg extensor muscles, an excessive load is applied to knee joint during mid stance of gait in patients, whereas in healthy subjects stronger knee-surrounding muscles provide stronger knee joint loading during gait. III (correlational study). Copyright © 2013 Elsevier B.V. All rights reserved.

  17. Effects of sex and obesity on gait biomechanics before and six months after total knee arthroplasty: A longitudinal cohort study.

    PubMed

    Paterson, K L; Sosdian, L; Hinman, R S; Wrigley, T V; Kasza, J; Dowsey, M; Choong, P; Bennell, K L

    2018-03-01

    Gait biomechanics, sex, and obesity can contribute to suboptimal outcomes from primary total knee arthroplasty. The aims of this study were to i) determine if sex and/or obesity influence the amount of change in gait biomechanics from pre-surgery to six months post-surgery and; ii) assess if gait returns to normal in men and women. Three-dimensional gait analysis was performed on 43 patients undergoing primary total knee arthroplasty for knee osteoarthritis (pre- and six months post-operative) and 40 asymptomatic controls. Mixed linear regression models were fit to assess which factors influenced change in gait biomechanics within the arthroplasty cohort, and interaction terms were included to assess if biomechanics returned to normal following surgery. Male peak knee adduction moment (p < 0.001) and impulse (p < 0.001) decreased six months following arthroplasty, whilst gait in women remained unchanged after surgery. Obesity did not influence gait changes in men or women. Gait of female arthroplasty participants did not differ from female controls after surgery except for sagittal plane knee range of motion (p = 0.003), whilst men differed from controls for peak knee adduction moment (p = 0.011), knee range of motion (p < 0.001), and peak knee flexion moment (p < 0.001). Sex, but not obesity, influenced changes in gait biomechanics after arthroplasty. Men retained abnormal gait patterns after surgery, whilst women did not. Further research should determine the long-term implications of gait abnormalities seen in men after arthroplasty. Copyright © 2018 Elsevier B.V. All rights reserved.

  18. The effect of patient age at intervention on risk of implant revision after total replacement of the hip or knee: a population-based cohort study.

    PubMed

    Bayliss, Lee E; Culliford, David; Monk, A Paul; Glyn-Jones, Sion; Prieto-Alhambra, Daniel; Judge, Andrew; Cooper, Cyrus; Carr, Andrew J; Arden, Nigel K; Beard, David J; Price, Andrew J

    2017-04-08

    Total joint replacements for end-stage osteoarthritis of the hip and knee are cost-effective and demonstrate significant clinical improvement. However, robust population based lifetime-risk data for implant revision are not available to aid patient decision making, which is a particular problem in young patient groups deciding on best-timing for surgery. We did implant survival analysis on all patients within the Clinical Practice Research Datalink who had undergone total hip replacement or total knee replacement. These data were adjusted for all-cause mortality with data from the Office for National Statistics and used to generate lifetime risks of revision surgery based on increasing age at the time of primary surgery. We identified 63 158 patients who had undergone total hip replacement and 54 276 who had total knee replacement between Jan 1, 1991, and Aug 10, 2011, and followed up these patients to a maximum of 20 years. For total hip replacement, 10-year implant survival rate was 95·6% (95% CI 95·3-95·9) and 20-year rate was 85·0% (83·2-86·6). For total knee replacement, 10-year implant survival rate was 96·1% (95·8-96·4), and 20-year implant survival rate was 89·7% (87·5-91·5). The lifetime risk of requiring revision surgery in patients who had total hip replacement or total knee replacement over the age of 70 years was about 5% with no difference between sexes. For those who had surgery younger than 70 years, however, the lifetime risk of revision increased for younger patients, up to 35% (95% CI 30·9-39·1) for men in their early 50s, with large differences seen between male and female patients (15% lower for women in same age group). The median time to revision for patients who had surgery younger than age 60 was 4·4 years. Our study used novel methodology to investigate and offer new insight into the importance of young age and risk of revision after total hip or knee replacement. Our evidence challenges the increasing trend for more total hip replacements and total knee replacements to be done in the younger patient group, and these data should be offered to patients as part of the shared decision making process. Oxford Musculoskeletal Biomedical Research Unit, National Institute for Health Research. Copyright © 2017 The Author(s). Published by Elsevier Ltd. This is an Open Access article under the CC BY license. Published by Elsevier Ltd.. All rights reserved.

  19. Pseudoaneurysm of the superior lateral genicular artery: case report of a rare complication after total knee arthroplasty.

    PubMed

    Saini, Pramod; Meena, Sanjay; Malhotra, Rajesh; Gamanagatti, Shivanand; Kumar, Vijay; Jain, Vaibhav

    2013-01-01

    Pseudoaneurysm of superior lateral genicular artery following total knee arthroplasty is a rare complication and has been reported following lateral release performed for eversion of patella in a knee with tight lateral structures. This report describes a case of pseudo aneurysm of superior lateral geniculate artery that developed after primary Total knee arthroplasty for a stiff knee in a 68 year old patient. Patient presented with pain and rapidly increasing swelling in early post operative period. Diagnosis was made on duplex ultrasound and confirmed by angiography. Angiographic coil embolisation of the pseudoaneurysm was performed. Since no lateral release was performed in this case, the probable mechanism was shear injury to the vessel. Pseudoaneurysm of superior lateral genicular artery can occur in absence of lateral release by shear injury to an atherosclerotic vessel. Angiographic coil embolisation appears to be the best method for treating such post arthroplasty pseudoaneurysm because of less chance of infection, non interference with rehabilitation and diagnosis and treatment during same procedure.

  20. Knee arthrodesis with the Vari-Wall nail for treatment of infected total knee arthroplasty.

    PubMed

    Garcia-Lopez, Ignacio; Aguayo, Miguel Anguel; Cuevas, Antonio; Navarro, Pablo; Prieto, Cristobal; Carpintero, Pedro

    2008-12-01

    We reviewed 20 patients who had undergone one-stage (7 cases) or two-stage (13 cases) knee arthrodesis using the Vari-Wall intramedullary nail, as a salvage operation following infection of a total knee arthroplasty. The procedure was followed by systemic antibiotic administration and early rehabilitation. Intraoperative microbiological cultures were taken. The average period of follow-up was 20 months. Solid union was achieved in 80%; mean time to fusion was 9 months. There was no recurrence of infection. The average limb length discrepancy was 2.45 cm. A walking aid was needed by 95% of the patients. The complication rate was 30% including 4 pseudarthroses, one intraoperative fracture and one peroneal nerve palsy. The Vari-Wall intramedullary nail is a good option when an arthrodesis is indicated for salvage of an infected total knee arthroplasty. It can be performed in one or two stages depending on several factors such as microbiologic culture results. It achieved good pain relief and acceptable functional results in this study.

  1. The risk of revision in total knee arthroplasty is not affected by previous high tibial osteotomy

    PubMed Central

    Badawy, Mona; Fenstad, Anne M; Indrekvam, Kari; Havelin, Leif I; Furnes, Ove

    2015-01-01

    Background and purpose — Previous studies have found different outcomes after revision of knee arthroplasties performed after high tibial osteotomy (HTO). We evaluated the risk of revision of total knee arthroplasty with or without previous HTO in a large registry material. Patients and methods — 31,077 primary TKAs were compared with 1,399 TKAs after HTO, using Kaplan-Meier 10-year survival percentages and adjusted Cox regression analysis. Results — The adjusted survival analyses showed similar survival in the 2 groups. The Kaplan-Meier 10-year survival was 93.8% in the primary TKA group and 92.6% in the TKA-post-HTO group. Adjusted RR was 0.97 (95% CI: 0.77–1.21; p = 0.8). Interpretation — In this registry-based study, previous high tibial osteotomy did not appear to compromise the results regarding risk of revision after total knee arthroplasty compared to primary knee arthroplasty. PMID:26058747

  2. Arthrodesis of the knee after failed knee replacement.

    PubMed

    Wade, P J; Denham, R A

    1984-05-01

    Arthrodesis of the knee is sometimes needed for failed total knee replacement, but fusion can be difficult to obtain. We describe a method of arthrodesis that uses the simple, inexpensive, Portsmouth external fixator. Bony union was obtained in all six patients treated with this technique. These results are compared with those obtained by other methods of arthrodesis.

  3. Pseudogout at the knee joint will frequently occur after hip fracture and lead to the knee pain in the early postoperative period.

    PubMed

    Harato, Kengo; Yoshida, Hiroki

    2015-01-14

    Symptomatic knee joint effusion is frequently observed after hip fracture, which may lead to postoperative knee pain during rehabilitation after hip fracture surgery. However, unfortunately, very little has been reported on this phenomenon in the literature. The purpose of the current study was to investigate the relationship between symptomatic knee effusion and postoperative knee pain and to clarify the reason of the effusion accompanied by hip fracture. A total of 100 patients over 65 years of age with an acute hip fracture after fall were prospectively followed up. Knee effusion was assessed on admission and at the operating room before the surgery. If knee effusion was observed at the time of the surgery, synovial fluid was collected into syringes to investigate the cause of the effusion using a compensated polarized light microscope. Furthermore, for each patient, we evaluated age, sex, radiographic knee osteoarthritis (OA), type of the fracture, laterality, severity of the fracture, and postoperative knee pain during rehabilitation. These factors were compared between patients with and without knee effusion at the time of the surgery. As a statistical analysis, we used Mann-Whitney U-test for patients' age and categorical variables were analyzed by chi-square test or Fisher's exact test. A total of 30 patients presented symptomatic knee effusion at the time of the surgery. In patients with knee effusion, numbers of intertrochanteric fracture, radiographic knee OA, and postoperative knee pain were significantly large compared to those without effusion. In terms of synovial fluid analysis, calcium pyrophosphate dihydrate crystals were observed in 80% of patients with knee effusion. From our study, approximately 63% of patients with knee effusion at the time of the surgery had postoperative knee pain. In addition, this effusion was basically related to pseudogout.

  4. [Total knee arthroplasty by lateral parapatellar approach for valgus knee].

    PubMed

    Zhou, Dian-ge; Zhang, Bin; Kou, Bo-long; Lü, Hou-shan

    2007-07-17

    To investigate the effect of lateral parapatellar approach in total knee arthroplasty (TKA) of valgus knee. Lateral parapatellar approach of total knee arthroplasty was applied in 8 patients (10 knees) with severe valgus osteoarthritis knee (bilateral in 2 cases and unilateral in 6 cases), with the valgus angle > 15 degrees , 1 male (1 knee) and 7 females (9 knee), aged 68.2 (58 - 79), 7 cases (9 knees) being of the Krackow type I and 1 case (1 knee) of the Krackow type I, I. After incision of the skin through lateral knee, ilio-tibial band was prolonged by apple pie arthroplasty. The joint capsule was cut open laterally 2 - 4 cm from the para-patellar edge. Soft tissue balance was performed by releasing I - T band in Gerdy tubercle, lateral collateral ligament and poster-lateral capsule from the femur and tibial side. Valgus angle of distal femur cutting were five degree. Whiteside line and trans-epicondylar line were used as AP rotational cutting reference. All patellar of the group were resurfaced. Capsule closure is completed with the knee flexed. The expanded deep lateral soft tissue sleeve (coronal Z-plasty) is sutured with the medial retinaculum sleeve (superficial layer). Follow-up was conducted for 19.6 months (1 - 51 months). Seven cases (9 knees) were replaced by posterior stabilized cemented prostheses (TC-Dynamic, PLUS), one case (1 knee) was replaced by RT prosthesis (RT-PLUS(TM) Solution, PLUS). After operation, the valgus deformity of all patients was corrected and all patients could walk 100 m with or without the help of walking holders. The average range of motion (ROM) was improved from the pre-operative. 95.6 degrees (85 degrees - 110 degrees ) to the post-operative 117.1 degrees (100 degrees - 125 degrees ). The average femorotibial angle (FTA) was corrected from the pre-operative. 27.6 degrees (20 degrees - 40 degrees ) to the post-operative 6.8 degrees (5 degrees - 9 degrees ). The Knee Score System (KSS) score and functional score were improved from the pre-operative 22.7 points (9 - 48 points) and 26.5 points (12 - 55 points) to the post-operative 86.4 points (85 - 95 points) and 89.1 points (80 - 95 points) respectively. Follow-up showed that the FTA remained unchanged and the knee stability of all patients was good. Through lateral approach, "Z" plasty of the capsule can release the lateral structure and decrease the pressure of common peroneal nerve. For TKR with moderate to severe fixed valgus knee, lateral approach is an effective way to correct the deformity.

  5. Arthrodesis with a short Huckstep nail as a salvage procedure for failed total knee arthroplasty.

    PubMed

    Lai, K A; Shen, W J; Yang, C Y

    1998-03-01

    Arthrodesis of the knee with use of a short Huckstep nail was performed in thirty-three patients (thirty-three knees) after failure of a non-constrained total knee arthroplasty. The indication for the arthrodesis was an infection in thirty-one knees and a Charcot joint in two. Three knees had had a failed attempt at arthrodesis with use of external fixation. The Huckstep nail was inserted through the knee, retrograde into the femur, and then antegrade into the tibia. The duration of the operation averaged 104 minutes (range, sixty-five to 155 minutes). Local bone graft was used in all knees. At the time of follow-up, at an average of forty-seven months (range, eighteen to ninety-four months), thirty knees (91 per cent) had radiographic evidence of union. The average time to union was 5.2 months (range, two to ten months) after the arthrodesis. Eight knees that had a grossly purulent infection were treated with debridement, which was followed by the arthrodesis as a second-stage procedure; the other knees had a one-stage arthrodesis. Only one of the thirty-one knees that had had an infection before the arthrodesis had a recurrence after it. Arthrodesis with a short Huckstep nail provides immediate axial and rotational stability and allows weight-bearing without use of external support as well as placement of the knee in a slightly flexed and valgus position. In addition, the nail does not migrate and it may be used even when there is a standard-size prosthesis in the ipsilateral hip.

  6. Characterizing the recovery trajectories of knee range of motion for one year after total knee replacement.

    PubMed

    Mehta, Saurabh; Rigney, Andrew; Webb, Kyle; Wesney, Jacob; Stratford, Paul W; Shuler, Franklin D; Oliashirazi, Ali

    2018-06-13

    Retrospective analysis of routinely collected clinical data. This study modeled the recovery in knee flexion and extension range of motion (ROM) over 1 year after total knee replacement (TKR). Recovery after TKR has been characterized for self-reported pain and functional status. Literature describing target knee ROM at different follow-up periods after TKR is scarce. Data were extracted for patients who had undergone TKR at a tertiary care hospital at 2, 8, 12, 26, and 52 weeks after TKR. A linear mixed-effects growth model was constructed that investigated the following covariates age, sex, pre-TKR range, body mass index, duration of symptoms, and their interaction with weeks post TKR. Of the 559 patients included (age 64.8 ± 8.5 years), 370 were women and 189 were men. Knee ROM showed the greatest change during the first 12 weeks after TKR, plateauing by 26 weeks. For an average patient, knee flexion increased from approximately 100º 2 weeks post TKR to 117º 52 weeks post TKR. Knee extension increased from approximately 3º knee flexion 2 weeks post TKR to 1º flexion 52 weeks post TKR. The results showed that the maximum gains in knee ROM should be expected within the first 12 weeks with small changes occurring up to 26 weeks after TKR. In addition, age and presurgery knee ROM are associated with the gains in knee ROM and should be factored into the estimation of expected knee ROM at a given follow-up interval after TKR.

  7. Biomechanical differences between unilateral and bilateral landings from a jump: gender differences.

    PubMed

    Pappas, Evangelos; Hagins, Marshall; Sheikhzadeh, Ali; Nordin, Margareta; Rose, Donald

    2007-07-01

    To determine the effect of landing type (unilateral vs. bilateral) and gender on the biomechanics of drop landings in recreational athletes. This study used a repeated measures design to compare bilateral and unilateral landings in male and female athletes. A repeated measures multivariate analysis of variance (type of landing*gender) was performed on select variables. Biomechanics laboratory. Sixteen female and 16 male recreational athletes. Kinetic, kinematic, and electromyographic (EMG) data were collected on participants while performing bilateral and unilateral landings from a 40-cm platform. Compared to bilateral landings, subjects performed unilateral landings with increased knee valgus, decreased knee flexion at initial contact, decreased peak knee flexion, decreased relative hip adduction, and increased normalized EMG of the rectus femoris, medial hamstrings, lateral hamstrings, and medial gastrocnemius (P < 0.005). During both types of landing, females landed with increased knee valgus and normalized vertical ground reaction force (VGRF) compared to males (P < 0.009), however, the interaction of landing type*gender was not significant (P = 0.29). Compared to bilateral landings, male and female recreational athletes performed unilateral landings with significant differences in knee kinematic and EMG variables. Female athletes landed with increased knee valgus and VGRF compared to males during both types of landing.

  8. Lactobacillus as a rare cause of an infected total knee replacement: a case report

    PubMed Central

    2009-01-01

    Introduction We report a rare case of an infected revision total knee replacement as a result of a Lactobacillus species infection. Lactobacillus infections have been associated with prolonged broad-spectrum antibiotic use. This can have implications in revision surgery, especially when patients have been on previous long-term suppressive antibiotic therapy. Case presentation An 81-year-old British man with a previous history of complex revision knee arthroplasty for infection presented with a hot, swollen knee joint. He had previously been on long-term suppressive antibiotic therapy. Aspiration of the knee joint yielded a culture of Lactobacillus species. Conclusion In patients undergoing revision joint arthroplasty, especially for previous infection, the presence of common and uncommon bacterial species must be excluded and eradicated before further surgical intervention. PMID:19830207

  9. 14-year median follow-up using the press-fit condylar sigma design for total knee arthroplasty.

    PubMed

    Patil, Shantanu S; Branovacki, George; Martin, Mersadies R; Pulido, Pamela A; Levy, Yadin D; Colwell, Clifford W

    2013-09-01

    Median 14-year follow-up (mean 11.8 years) of a cemented primary posterior cruciate-retaining total knee arthroplasty (TKA) utilizing the Press-Fit Condylar (PFC) Sigma design was evaluated in 77 patients (79 TKA). Follow-up assessment included implant survivorship, x-rays, Knee Society rating system, and clinical evaluation. Radiographic analysis demonstrated minor non-progressive osteolysis in 40% (10/25) knees. Two revisions, one for instability at 4 years and one for polyethylene wear at 10 years were performed. Survivorship of the PFC Sigma knee implant was 97% using revision for any reason and 100% using aseptic loosening as endpoints. The PFC Sigma had excellent survivorship at 14 years, the longest clinical follow-up reported. Copyright © 2013 Elsevier Inc. All rights reserved.

  10. Why total knees fail-A modern perspective review.

    PubMed

    Lum, Zachary C; Shieh, Alvin K; Dorr, Lawrence D

    2018-04-18

    Historically, the most common mechanism of total knee arthroplasty (TKA) failures included aseptic loosening, instability and malalignment. As polyethylene production improved, modes of failure from polyethylene wear and subsequent osteolysis became less prevalent. Newer longitudinal studies report that infection has become the primary acute cause of failure with loosening and instability remaining as the overall greatest reasons for revision. Clinical database and worldwide national registries confirm these reports. With an increasing amount of TKA operations performed in the United States, and with focus on value-based healthcare, it is imperative to understand why total knees fail.

  11. Arthrodesis following failed total knee arthroplasty: comprehensive review and meta-analysis of recent literature.

    PubMed

    Damron, T A; McBeath, A A

    1995-04-01

    With the increasing duration of follow up on total knee arthroplasties, more revision arthroplasties are being performed. When revision is not advisable, a salvage procedure such as arthrodesis or resection arthroplasty is indicated. This article provides a comprehensive review of the literature regarding arthrodesis following failed total knee arthroplasty. In addition, a statistical meta-analysis of five studies using modern arthrodesis techniques is presented. A statistically significant greater fusion rate with intramedullary nail arthrodesis compared to external fixation is documented. Gram negative and mixed infections are found to be significant risk factors for failure of arthrodesis.

  12. Knee and Ankle Arthroplasty in Hemophilia

    PubMed Central

    Solimeno, Luigi Piero; Pasta, Gianluigi

    2017-01-01

    Today, major surgical procedures can be safely performed in hemophilic patients with chronic arthropathy, using available factor concentrates. In this setting, total knee replacement is considered the “gold standard”, while the use of total ankle replacement is still debated. Indeed, the unsatisfactory results obtained with the previous available design of implants did not raise enthusiasm as knee or hip replacement. Recently, the introduction of new implant designs and better reported outcomes have renewed the interest in total ankle replacement in people with hemophilia. In this review, the role of replacement surgery in the treatment of chronic hemophilic arthropathy will be described. PMID:29165342

  13. A comparison of short term radiological alignment outcomes of the patient specific and standard instrumentation for primary total knee arthroplasty: A systematic review and meta-analysis.

    PubMed

    Alcelik, Ilhan; Blomfield, Mark; Öztürk, Cenk; Soni, Ashish; Charity, Richard; Acornley, Alex

    2017-05-01

    The aim of this study was to review the radiological alignment outcomes of patient Specific (PS) cutting blocks and Standard Instrumentation in Primary Total Knee Arthroplasty. We hypothesized that the use of PS techniques would significantly improve sagittal, coronal and rotational alignment of the prosthesis on short term. We performed a systematic review and a meta-analysis including all the randomised controlled trials (RCT) using PS and standard (ST) total knee arthroplasty to date. A total of 538 PS TKA and 549 ST TKA were included in the study. Statistical analysis of the outliers for femoral component sagittal, coronal and rotational positioning, tibial component sagittal and coronal positioning and the overall mechanical axis were assessed. We found that there was no significant benefit from using PS instrumentation in primary knee arthroplasty to aid in the positioning of either the tibial or femoral components. Furthermore sagittal plane tibial component positioning was worse in the PS than the traditional ST group. Our results suggest that at present PS instrumentation is not superior to ST instrumentation in primary total knee arthroplasty. Level 1, Systematic review of therapeutic studies. Copyright © 2017 Turkish Association of Orthopaedics and Traumatology. Production and hosting by Elsevier B.V. All rights reserved.

  14. Management of knee rheumatoid arthritis and tibia nonunion with one-stage total knee arthroplasty and intramedullary nailing: A report of two cases.

    PubMed

    Erdogan, Fahri; Sarikaya, Ilker Abdullah; Can, Ata; Gorgun, Baris

    2018-01-01

    Total knee arthroplasty (TKA) is a surgical procedure which is widely used in the treatment of gonarthrosis secondary to rheumatoid arthritis (RA). The incidence of stress fractures in tibia in the patients with RA is higher compared to normal patients. In this study, we report two cases of TKA and intramedullary nailing in RA patients with severe knee arthritis and tibial nonunion. Both patients had a satisfactory clinical outcome with radiological healing of the tibial fracture. Copyright © 2017 Turkish Association of Orthopaedics and Traumatology. Production and hosting by Elsevier B.V. All rights reserved.

  15. Measurement-noise maximum as a signature of a phase transition.

    PubMed

    Chen, Zhi; Yu, Clare C

    2007-02-02

    We propose that a maximum in measurement noise can be used as a signature of a phase transition. As an example, we study the energy and magnetization noise spectra associated with first- and second-order phase transitions by using Monte Carlo simulations of the Ising model and 5-state Potts model in two dimensions. For a finite size system, the total noise power and the low frequency white noise S(f0 and the total noise power vanishes. f(-1)(knee) is approximately the equilibration time.

  16. Accuracy verification of the photostereometric system KKN/1B developed for intraoperative measurement of knee movement immediately after total knee arthroplasty.

    PubMed

    Nishino, K; Hayashi, T; Suzuki, Y; Koga, Y; Omori, G

    1999-01-01

    The function and integrity of the knee joint following total knee arthroplasty (TKA) is determined at first by the design and implantation of the prosthesis, and later by the tension of soft tissues surrounding it. Accurate post-TKA motion data obtained intraoperatively could be used not only to optimize implantation techniques from a kinematic standpoint, but also to improve prosthetic design. We therefore developed a system specifically geared to photostereometric measurement of 6 d.o.f. knee motion. A total of eight LEDs are mounted on the prosthetic components in two sets of four by means of connecting measuring-bows. The positions of the LEDs are detected in three-dimensions by two sets of three linear CCD cameras, located bilaterally relative to the knee. The position and orientation of the femoral component relative to the tibial one are estimated from the positions of all LEDs in the sense of least-squares. Based upon results of various accuracy validation experiments performed after precise camera calibration, static overall accuracy and spatial resolution were considered to lie within 0.52 and 0.11 mm, respectively, at any point on the femoral articular surface.

  17. Expect the best, prepare for the worst: surgeon and patient expectation of the outcome of primary total hip and knee replacement.

    PubMed Central

    Moran, M.; Khan, A.; Sochart, D. H.; Andrew, G.

    2003-01-01

    A cross-sectional study of 100 surgeons and 370 patients awaiting primary total hip or knee replacement was carried out. Oxford hip or knee score questionnaires were sent to the surgeons and patients. They were asked to predict the level of symptoms expected 6 months following surgery. The Oxford scores derive a value of 12-60, with a greater score indicating worsening symptoms. The mean pre-operative score was 45.12 for the hip patients and 42.96 for the knee patients, and the patients expected this to drop to 23.70 and 25.66, respectively, 6 months' postoperatively. This was a significant difference for both groups. The surgeons expected the patients to have a mean postoperative score of 20.91 for the hip group and 22.19 for the knee group. The surgeons' scores were significantly lower than those from the patients. There was a significant difference between the patients' and surgeons' expectations of the results of total knee and hip replacement surgery. The surgeons expected better results than the patients. We believe that this is the first study that directly compares surgeon and patient expectations of lower limb arthroplasty. PMID:12831497

  18. No associations between self-reported knee joint instability and radiographic features in knee osteoarthritis patients prior to Total Knee Arthroplasty: A cross-sectional analysis of the Longitudinal Leiden Orthopaedics Outcomes of Osteo-Arthritis study (LOAS) data.

    PubMed

    Leichtenberg, Claudia S; Meesters, Jorit J L; Kroon, Herman M; Verdegaal, Suzan H M; Tilbury, Claire; Dekker, Joost; Nelissen, Rob G H H; Vliet Vlieland, Thea P M; van der Esch, Martin

    2017-08-01

    To describe the prevalence of self-reported knee joint instability in patients with pre-surgery knee osteoarthritis (OA) and to explore the associations between self-reported knee joint instability and radiological features. A cross-sectional study including patients scheduled for primary Total Knee Arthroplasty (TKA). Self-reported knee instability was examined by questionnaire. Radiological features consisted of osteophyte formation and joint space narrowing (JSN), both scored on a 0 to three scale. Scores >1 are defined as substantial JSN or osteophyte formation. Regression analyses were provided to identify associations of radiological features with self-reported knee joint instability. Two hundred and sixty-five patients (mean age 69years and 170 females) were included. Knee instability was reported by 192 patients (72%). Substantial osteophyte formation was present in 78 patients (41%) reporting and 33 patients (46%) not reporting knee joint instability. Substantial JSN was present in 137 (71%) and 53 patients (73%), respectively. Self-reported knee instability was not associated with JSN (relative to score 0, odds ratios (95% CI) of score 1, 2 and 3 were 0.87 (0.30-2.54), 0.98 (0.38-2.52), 0.68 (0.25-1.86), respectively) or osteophyte formation (relative to score 0, odds ratios (95% CI) of score 1, 2 and 3 were 0.77 (0.36-1.64), 0.69 (0.23-1.45), 0.89 (0.16-4.93), respectively). Stratified analysis for pain, age and BMI showed no associations between self-reported knee joint instability and radiological features. Self-reported knee joint instability is not associated with JSN or osteophyte formation. Copyright © 2017 Elsevier B.V. All rights reserved.

  19. Blood loss associated with Ring uncemented total knee replacement: comparison between continuous and intermittent suction drainage.

    PubMed Central

    Wittmann, F W; Ring, P A

    1984-01-01

    In a retrospective comparison of blood loss following uncemented total knee replacement, in which either continuous or intermittent suction drainage was used, measured blood loss was significantly greater with continuous drainage. However, a method of calculating actual blood loss demonstrated no significant difference. With intermittent drainage, more blood remains undetected around the knee joint; this technique should therefore be abandoned in favour of continuous suction drainage. PMID:6747978

  20. Periarticular regional analgesia in total knee arthroplasty: a review of the neuroanatomy and injection technique.

    PubMed

    Guild, George N; Galindo, Rubin P; Marino, Joseph; Cushner, Fred D; Scuderi, Giles R

    2015-01-01

    Postoperative pain control after total knee arthroplasty may be insufficient, resulting in insomnia, antalgic ambulation, and difficulty with rehabilitation. Current strategies, including the use of femoral nerve catheters, may control pain but have been associated with falls, motor blockade, and quadriceps inhibition. Periarticular infiltration using the appropriate technique and knowledge of intraarticular knee anatomy may increase pain control and maximize rehabilitation. Copyright © 2015 Elsevier Inc. All rights reserved.

  1. The role of the posterior cruciate ligament in total knee replacement

    PubMed Central

    Ritter, M. A.; Davis, K. E.; Meding, J. B.; Farris, A.

    2012-01-01

    Objectives The purpose of this study was to examine the effect of posterior cruciate ligament (PCL) retention, PCL recession, and PCL excision during cruciate-retaining total knee replacement. Methods A total of 3018 anatomic graduated component total knee replacements were examined; 1846 of these retained the PCL, 455 PCLs were partially recessed, and in 717 the PCL was completely excised from the back of the tibia. Results Clinical scores between PCL groups favored excision for flexion (p < 0.0001), and recession and retention for stairs (p < 0.0001). There was a mild difference in long-term all-cause aseptic survivorship between PCL-retained (96.4% at 15 years) combined with PCL-recessed groups (96.6% at 15 years) when compared with the PCL-excised group (95.0% at 15 years) (p = 0.0411, Wilcoxon; p = 0.0042, log-rank), as well as tibial or femoral loosening, which reported prosthesis survival of 97.8% at 15 years for PCL-retained knees, 98.2% for recessed knees, and 96.4% for excised knees (p = 0.0934, Wilcoxon; p = 0.0202, log-rank). Conclusions Despite some trade off in clinical performance, if the PCL is detached at the time of operation, conversion to a posterior-stabilised prosthesis may not be necessarily required as long as stability in the anteroposterior and coronal planes is achieved. PMID:23610673

  2. Kinematic analysis of hip and knee rotation and other contributors to ballet turnout.

    PubMed

    Quanbeck, Amy E; Russell, Jeffrey A; Handley, Sara C; Quanbeck, Deborah S

    2017-02-01

    Turnout, or external rotation (ER) of the lower extremities, is essential in ballet. The purpose of this study was to utilise physical examination and a biomechanical method for obtaining functional kinematic data using hip and knee joint centres to identify the relative turnout contributions from hip rotation, femoral anteversion, knee rotation, tibial torsion, and other sources. Ten female dancers received a lower extremity alignment assessment, including passive hip rotation, femoral anteversion, tibial torsion, weightbearing foot alignment, and Beighton hypermobility score. Next, turnout was assessed using plantar pressure plots and three-dimensional motion analysis; participants performed turnout to ballet first position on both a plantar pressure mat and friction-reducing discs. A retro-reflective functional marker motion capture system mapped the lower extremities and hip and knee joint centres. Mean total turnout was 129±15.7° via plantar pressure plots and 135±17.8° via kinematics. Bilateral hip ER during turnout was 49±10.2° (36% of total turnout). Bilateral knee ER during turnout was 41±5.9° (32% of total turnout). Hip ER contribution to total turnout measured kinematically was less than expected compared to other studies, where hip ER was determined without functional kinematic data. Knee ER contributed substantially more turnout than expected or previously reported. This analysis method allows precise assessment of turnout contributors.

  3. Morphometric evaluation of the knee in Chinese population reveals sexual dimorphism and age-related differences.

    PubMed

    Li, Ke; Cavaignac, Etienne; Xu, Wei; Cheng, Qiang; Telmon, Nobert; Huang, Wei

    2018-02-20

    Morphologic data of the knee is very important in the design of total knee prostheses. Generally, the designs of the total knee prostheses are based on the knee anatomy of Caucasian population. Moreover, in forensic medicine, a person's age and sex might be estimated by the shape of their knees. The aim of this study is to utilize three-dimensional morphometric analysis of the knee in Chinese population to reveal sexual dimorphism and age-related differences. Sexually dimorphic differences and age-related differences of the distal femur were studied by using geometric morphometric analysis of ten osteometric landmarks on three-dimensional reconstructions of 259 knees in Chinese population. General Procrustes analysis, PCA, and other discriminant analysis such as Mahalanobis and Goodall's F test were conducted for the knee to identify sexually dimorphism and age-related differences of the knee. The shape of distal femur between the male and female is significantly different. A difference between males and females in distal femur shape was identified by PCA; PC1 and PC2 accounted for 61.63% of the variance measured. The correct sex was assigned in 84.9% of cases by CVA, and the cross-validation revealed a 81.1% rate of correct sex estimation. The osteometric analysis also showed significant differences between the three age-related subgroups (< 40, 40-60, > 60 years, p < 0.005). This study showed both sex-related difference and age-related difference in the distal femur in Chinese population by 3D geometric morphometric analysis. Our bone measurements and geometric morphometric analysis suggest that population characteristics should be taken into account and may provide references for design of total knee prostheses in a Chinese population. Moreover, this reliable, accurate method could be used to perform diachronic and interethnic comparisons.

  4. Total Knee Arthroplasty In Patients With Parkinson's Disease- A Critical Analysis of Available Evidence.

    PubMed

    Ashraf, Munis; Priyavadhana, Sruthi; Sambandam, Senthil Nathan; Mounasamy, Varatharaj; Sharma, Om Prakash

    2017-01-01

    In this era of modern medicine, there is an increase in life expectancy and thereby an ageing population. Among this group one of the most common neurological disorder is Parkinson disease and one of the most common operation done in elderly population is a total joint arthroplasty. But total joint arthroplasty in Parkinson disease is a relatively uncommon entity. There is sparse literature available with regards to total knee arthroplasty (TKA) in Parkinson disease. This review focusses on the necessity, complications and previous experiences on TKA in PD based on the literature available. The review was conducted after a series of advanced search in the following medical databases; Pub med, Biomed central, Cochrane and Google scholar for articles related to total knee replacement in patients with Parkinson's disease. The following keywords were used; Total knee arthroplasty, Parkinson's disease, Hoehn and Yahr, Flexion Contracture. The review indicates that the functional outcome is comparable to that of controls in immediate post-operative phase, one year and three-year phase, but the long term functional outcome seems to deteriorate significantly. Total knee arthroplasty can serve as an effective tool in alleviating pain in short term as well as long term periods, whereas the functional outcome seems to deteriorate post operatively on a long-term basis. Nevertheless, TKA in PD is a challenging situation, thereby necessitating a holistic approach with the efforts from various specialists needed at each stage to ensure a successful operation.

  5. Particle size and morphology of UHMWPE wear debris in failed total knee arthroplasties--a comparison between mobile bearing and fixed bearing knees.

    PubMed

    Huang, Chun-Hsiung; Ho, Fang-Yuan; Ma, Hon-Ming; Yang, Chan-Tsung; Liau, Jiann-Jong; Kao, Hung-Chan; Young, Tai-Horng; Cheng, Cheng-Kung

    2002-09-01

    Osteolysis induced by ultrahigh molecular weight polyethylene wear debris has been recognized as the major cause of long-term failure in total joint arthroplasties. In a previous study, the prevalence of intraoperatively identified osteolysis during primary revision surgery was much higher in mobile bearing knee replacements (47%) than in fixed bearing knee replacements (13%). We postulated that mobile bearing knee implants tend to produce smaller sized particles. In our current study, we compared the particle size and morphology of polyethylene wear debris between failed mobile bearing and fixed bearing knees. Tissue specimens from interfacial and lytic regions were extracted during revision surgery of 10 mobile bearing knees (all of the low contact stress (LCS) design) and 17 fixed bearing knees (10 of the porous-coated anatomic (PCA) and 7 of the Miller/Galante design). Polyethylene particles were isolated from the tissue specimens and examined using both scanning electron microscopy and light-scattering analyses. The LCS mobile bearing knees produced smaller particulate debris (mean equivalent spherical diameter: 0.58 microm in LCS, 1.17 microm in PCA and 5.23 microm in M/G) and more granular debris (mean value: 93% in LCS, 77% in PCA and 15% in M/G).

  6. Five year survival analysis of an oxidised zirconium total knee arthroplasty.

    PubMed

    Holland, Philip; Santini, Alasdair J A; Davidson, John S; Pope, Jill A

    2013-12-01

    Zirconium total knee arthroplasties theoretically have a low incidence of failure as they are low friction, hard wearing and hypoallergenic. We report the five year survival of 213 Profix zirconium total knee arthroplasties with a conforming all polyethylene tibial component. Data was collected prospectively and multiple strict end points were used. SF12 and WOMAC scores were recorded pre-operatively, at three months, at twelve months, at 3 years and at 5 years. Eight patients died and six were "lost to follow-up". The remaining 199 knees were followed up for five years. The mean WOMAC score improved from 56 to 35 and the mean SF12 physical component score improved from 28 to 34. The five year survival for failure due to implant related reasons was 99.5% (95% CI 97.4-100). This was due to one tibial component becoming loose aseptically in year zero. Our results demonstrate that the Profix zirconium total knee arthroplasty has a low medium term failure rate comparable to the best implants. Further research is needed to establish if the beneficial properties of zirconium improve long term implant survival. Copyright © 2012 Elsevier B.V. All rights reserved.

  7. Knee joint distraction compared with total knee arthroplasty: a randomised controlled trial.

    PubMed

    van der Woude, J A D; Wiegant, K; van Heerwaarden, R J; Spruijt, S; Emans, P J; Mastbergen, S C; Lafeber, F P J G

    2017-01-01

    Knee joint distraction (KJD) is a relatively new, knee-joint preserving procedure with the goal of delaying total knee arthroplasty (TKA) in young and middle-aged patients. We present a randomised controlled trial comparing the two. The 60 patients ≤ 65 years with end-stage knee osteoarthritis were randomised to either KJD (n = 20) or TKA (n = 40). Outcomes were assessed at baseline, three, six, nine, and 12 months. In the KJD group, the joint space width (JSW) was radiologically assessed, representing a surrogate marker of cartilage thickness. In total 56 patients completed their allocated treatment (TKA = 36, KJD = 20). All patient reported outcome measures improved significantly over one year (p < 0.02) in both groups. At one year, the TKA group showed a greater improvement in only one of the 16 patient-related outcome measures assessed (p = 0.034). Outcome Measures in Rheumatology-Osteoarthritis Research Society International clinical response was 83% after TKA and 80% after KJD. A total of 12 patients (60%) in the KJD group sustained pin track infections. In the KJD group both mean minimum (0.9 mm, standard deviation (sd) 1.1) and mean JSW (1.2 mm, sd 1.1) increased significantly (p = 0.004 and p = 0.0003). In relatively young patients with end-stage knee osteoarthritis, KJD did not demonstrate inferiority of outcomes at one year when compared with TKA. However, there is a high incidence of pin track infection associated with KJD. Cite this article: Bone Joint J 2017;99-B:51-8. ©2017 The British Editorial Society of Bone & Joint Surgery.

  8. A non-invasive measurement of the knee contact force using a subject-specific musculoskeletal model to investigate osteotomy.

    PubMed

    Badie, Fateme; Katouzian, Hamid Reza; Rostami, Mostafa

    2018-06-18

    The varus knee has been defined as a Hip-Knee-Ankle alignment of less than 180 degrees. Varus knee alignment increases the load on the medial knee and also the risk of osteoarthritis. High tibial osteotomy has been designed to modify the malalignment of varus knee. The aim of this study was to investigate the osteotomy effects on knee adduction moment (KAM) and contact forces using a musculoskeletal and subject-specific knee model. A patient with varus knee and no symptoms of any other disease or disability participated in this study. The geometry of the multibody knee model has been modified using MR images. The solutions of its finite element model have been used to determine the parameters of the multibody model. The motion data, ground reaction force and kinetic data have been applied to run the subject-specific musculoskeletal model during the stance phase of gait. After osteotomy, the adduction moment decreased, where the maximum values are comparable to other studies. The pattern of KAM did not witness any significant changes. The total and medial contact forces reduced considerably after surgery, but the lateral contact force did not significantly change. The changes in total and medial contact forces and lack of change in lateral contact force could be explained by modification of the gait pattern after surgery.

  9. Analysis of in vitro and in vivo function of total knee replacements using dynamic contact models

    NASA Astrophysics Data System (ADS)

    Zhao, Dong

    Despite the high incidence of osteoarthritis in human knee joint, its causes remain unknown. Total knee replacement (TKR) has been shown clinically to be effective in restoring the knee function. However, wear of ultra-high molecular weight polyethylene has limited the longevity of TKRs. To address these important issues, it is necessary to investigate the in vitro and in vivo function of total knee replacements using dynamic contact models. A multibody dynamic model of an AMTI knee simulator was developed. Incorporating a wear prediction model into the contact model based on elastic foundation theory enables the contact surface to take into account creep and wear during the dynamic simulation. Comparisons of the predicted damage depth, area, and volume lost with worn retrievals from a physical machine were made to validate the model. In vivo tibial force distributions during dynamic and high flexion activities were investigated using the dynamic contact model. In vivo medial and lateral contact forces experienced by a well-aligned instrumented knee implant, as well as upper and lower bounds on contact pressures for a variety of activities were studied. For all activities, the predicted medial and lateral contact forces were insensitive to the selected material model. For this patient, the load split during the mid-stance phase of gait and during stair is more equal than anticipated. The external knee adduction torque has been proposed as a surrogate measure for medial compartment load during gait. However, a direct link between these two quantities has not been demonstrated using in vivo measurement of medial compartment load. In vivo data collected from a subject with an instrumented knee implant were analyzed to evaluate this link. The subject performed five different overground gait motions (normal, fast, slow, wide, and toe out) while instrumented implant, video motion, and ground reaction data were simultaneously collected. The high correlation coefficient results support the hypothesis that the knee adduction torque is highly correlated with medial compartment contact force and medial to total force ratio during gait.

  10. Periprosthetic fractures of the femur after total knee arthroplasty.

    PubMed

    McGraw, Phil; Kumar, Arun

    2010-09-01

    Periprosthetic fracture following total knee arthroplasty is a potentially serious complication. This injury can involve the distal femur, proximal tibia or the patella. This review article analyzes the prevalence, risk factors, classification and treatment options for periprosthetic fractures of the femur.

  11. Evaluation of 3D printed anatomically scalable transfemoral prosthetic knee.

    PubMed

    Ramakrishnan, Tyagi; Schlafly, Millicent; Reed, Kyle B

    2017-07-01

    This case study compares a transfemoral amputee's gait while using the existing Ossur Total Knee 2000 and our novel 3D printed anatomically scalable transfemoral prosthetic knee. The anatomically scalable transfemoral prosthetic knee is 3D printed out of a carbon-fiber and nylon composite that has a gear-mesh coupling with a hard-stop weight-actuated locking mechanism aided by a cross-linked four-bar spring mechanism. This design can be scaled using anatomical dimensions of a human femur and tibia to have a unique fit for each user. The transfemoral amputee who was tested is high functioning and walked on the Computer Assisted Rehabilitation Environment (CAREN) at a self-selected pace. The motion capture and force data that was collected showed that there were distinct differences in the gait dynamics. The data was used to perform the Combined Gait Asymmetry Metric (CGAM), where the scores revealed that the overall asymmetry of the gait on the Ossur Total Knee was more asymmetric than the anatomically scalable transfemoral prosthetic knee. The anatomically scalable transfemoral prosthetic knee had higher peak knee flexion that caused a large step time asymmetry. This made walking on the anatomically scalable transfemoral prosthetic knee more strenuous due to the compensatory movements in adapting to the different dynamics. This can be overcome by tuning the cross-linked spring mechanism to emulate the dynamics of the subject better. The subject stated that the knee would be good for daily use and has the potential to be adapted as a running knee.

  12. Learning curve for new technology?: a nationwide register-based study of 46,363 total knee arthroplasties.

    PubMed

    Peltola, Mikko; Malmivaara, Antti; Paavola, Mika

    2013-12-04

    The risk of early revision is increased for the first patients operatively treated with a newly introduced knee prosthesis. In this study, we explored the learning curves associated with ten knee implant models to determine their effect on early revision risk. We studied register data from all seventy-five surgical units that performed knee arthroplasty in Finland from 1998 to 2007. Of 54,925 patients (66,098 knees), 39,528 patients (46,363 knees) underwent arthroplasty for osteoarthritis of the knee with the ten most common total knee implants and were followed with complete data until December 31, 2010, or the time of death. We used a Cox proportional-hazards regression model for calculating the hazard ratios for early revision for the first fifteen arthroplasties and subsequent increments of numbers of arthroplasties. We found large differences among knee implants at the introduction with regard to the risk of early revision, as well as for the overall risk of early revision. A learning curve was found for four implant models, while six models did not show a learning effect on the risk of early revision. The survivorship of the studied prostheses showed substantial differences. Knee implants have model-specific learning curves and early revision risks. Some models are more difficult to implement than others. The manufacturers should consider the learning effect when designing implants and instrumentation. The surgeons should thoroughly familiarize themselves with the new knee implants before use.

  13. Navigation-Assisted Total Knee Arthroplasty for Patients with Extra-Articular Deformity

    PubMed Central

    Rhee, Seung Joon; Seo, Chang Hyo

    2013-01-01

    Purpose Since the existence of an extra-articular deformity seriously alters the normal geometry and kinetics around the knee joint, difficulties are often encountered in total knee arthroplasty (TKA) using a standard surgical technique. The purpose of this study was to evaluate the usefulness of surgical navigation system as a treatment option for osteoarthritic knees with extra-articular deformity. Materials and Methods The authors retrospectively reviewed medical records of the patients who underwent primary TKA between 2007 and 2012. Knees with preoperative radiography showing an angular deformity within the region from the middle third of the femur to the middle third of the tibia in the ipsilateral limb of the arthritic knees were considered as cases having extra-articular deformity. Thirteen knees of the 13 patients were found to have undergone TKA using a navigation system for osteoarthritis with ipsilateral extra-articular deformity. The hip-knee-ankle angle, Knee Society score (KSS), and range of motion were measured before and after the operation to evaluate the improvement. Results The mean hip-knee-ankle angle in the coronal plane was improved to 0.2°±4.5° in valgus alignment postoperatively. The KSS was improved to 89.6±4.6 points postoperatively at the last follow-up, with over 90% of good and excellent results. The range of motion was improved to 118.5°±10.5° postoperatively. Conclusions Navigation-assisted TKA is a good treatment option of osteoarthritic knees with extra-articular deformity. PMID:24368997

  14. Revision total knee arthroplasty for septic versus aseptic failure.

    PubMed

    Rajgopal, Ashok; Vasdev, Attique; Gupta, Himanshu; Dahiya, Vivek

    2013-12-01

    To compare the medium-term outcome of revision total knee arthroplasty (TKA) for septic versus aseptic failure. Records of 142 patients who underwent revision TKA by a single senior surgeon for septic (n=65) or aseptic (n=77) failure were reviewed. In the septic group, 67 knees in 42 women and 23 men were included. In the aseptic group, 88 knees in 51 women and 26 men were included. The Knee Society Score was measured. The Kaplan Meier survival curve at months 36, 60, and 95 was plotted, with revision as the end point. The survival rates at each specific time point between the 2 groups were compared using the Z test. The Knee Society Scores improved 18% from 51 to 69 in the septic group and 18% from 52 to 70 in the aseptic group (p=0.72). The range of motion improved 30% from 72 to 102 degrees in the septic group and 39% from 62 to 100 degrees in the aseptic group (p<0.001). Results of the 2 groups were similar in terms of the Knee Society Score, range of motion, and the Kaplan-Meier survivorship.

  15. Selective peripheral nerve resection for treatment of persistent pain around the knee joint after total knee arthroplasty.

    PubMed

    Zhong, Guangjun; Liang, Zhu; Kan, Jiang; Muheremu, Aikeremujiang

    2018-01-01

    Objective This study was performed to determine the efficacy of selective peripheral nerve resection for treatment of persistent neuropathic pain after total knee arthroplasty (TKA). Methods Patients who underwent TKA in our department from January 2013 to July 2016 and experienced persistent pain around the knee joint after TKA were retrospectively included in the current study. Sixty patients were divided into experimental and control groups according the treatment they received. The treatment effect was evaluated by the Hospital for Special Surgery (HSS) knee score and visual analog scale (VAS) pain score preoperatively and at 1, 2, 3, 6, and 12 months postoperatively. Results The HSS knee scores were higher in both groups after than before the treatment, and HSS knee scores were significantly higher in the experimental group than in the control group. The VAS pain scores were lower in both groups after than before the treatment, and VAS pain scores were significantly lower in the experimental group than in the control group. Conclusions Selective peripheral nerve resection is an effective treatment method for persistent neuropathic pain after TKA.

  16. Embedded piezoelectrics for sensing and energy harvesting in total knee replacement units

    NASA Astrophysics Data System (ADS)

    Wilson, Brooke E.; Meneghini, Michael; Anton, Steven R.

    2015-04-01

    The knee replacement is the second most common orthopedic surgical intervention in the United States, but currently only 1 in 5 knee replacement patients are satisfied with their level of pain reduction one year after surgery. It is imperative to make the process of knee replacement surgery more objective by developing a data driven approach to ligamentous balance, which increases implant life. In this work, piezoelectric materials are considered for both sensing and energy harvesting applications in total knee replacement implants. This work aims to embed piezoelectric material in the polyethylene bearing of a knee replacement unit to act as self-powered sensors that will aid in the alignment and balance of the knee replacement by providing intraoperative feedback to the surgeon. Postoperatively, the piezoelectric sensors can monitor the structural health of the implant in order to perceive potential problems before they become bothersome to the patient. Specifically, this work will present on the use of finite element modeling coupled with uniaxial compression testing to prove that piezoelectric stacks can be utilized to harvest sufficient energy to power sensors needed for this application.

  17. Comparison of clinical outcomes between total knee arthroplasty and unicompartmental knee arthroplasty for osteoarthritis of the knee: a retrospective analysis of preoperative and postoperative results.

    PubMed

    Horikawa, Akira; Miyakoshi, Naohisa; Shimada, Yoichi; Kodama, Hiroyuki

    2015-10-28

    Excellent results have recently been reported for both total knee arthroplasty (TKA) and unicompartmental knee arthroplasty (UKA), but there have been few reports about which has a better long-term outcome. The preoperative and postoperative results of TKA and UKA for osteoarthritis of the knee were thus compared. The results of 48 patients who underwent TKA and 25 patients who underwent UKA were evaluated based on clinical scores and survivorship in the middle long-term period. Preoperative, latest postoperative, and changes in the femoro-tibial angle (FTA), range of motion (ROM), Japanese Orthopedic Association score (JOA score), and Japanese Knee Osteoarthritis Measure (JKOM) were compared. The patients' mean age was 73 years. The mean follow-up period was 9 years (TKA: mean, 10.5 years; range, 7-12 years; UKA: mean, 9 years; range, 6-11 years). Preoperative FTA and ROM were significantly higher in the UKA group than in the TKA group. Total changes in all scores were similar among the two groups, as were changes in scores for all JOA and JKOM domains. The cumulative revision rate was higher for UKA than for TKA (7 versus 4%). Kaplan-Meier survivorship at 10 years was 84% for UKA and 92% for TKA. This clinical study found no significant differences between TKA and UKA, except in long-term survivorship.

  18. Evaluation of the relationship between anteroposterior translation of a posterior cruciate ligament-retaining total knee replacement and functional outcome.

    PubMed

    Seah, R B; Pang, H N; Lo, N N; Chong, H C; Chin, P L; Chia, S L; Yeo, S J

    2012-10-01

    The success of total knee replacement (TKR) depends on optimal soft-tissue balancing, among many other factors. The objective of this study is to correlate post-operative anteroposterior (AP) translation of a posterior cruciate ligament-retaining TKR with clinical outcome at two years. In total 100 patients were divided into three groups based on their AP translation as measured by the KT-1000 arthrometer. Group 1 patients had AP translation < 5 mm, Group 2 had AP translation from 5 mm to 10 mm, and Group 3 had AP translation > 10 mm. Outcome assessment included range of movement of the knee, the presence of flexion contractures, hyperextension, knee mechanical axes and functional outcome using the Knee Society score, Oxford knee score and the Short-Form 36 questionnaire. At two years, patients in Group 2 reported significantly better Oxford knee scores than the other groups (p = 0.045). A positive correlation between range of movement and AP translation was noted, with patients in group 3 having the greatest range of movement (mean flexion: 117.9° (106° to 130°)) (p < 0.001). However, significantly more patients in Group 3 developed hyperextension > 10° (p = 0.01). In this study, the best outcome for cruciate-ligament retaining TKR was achieved in patients with an AP translation of 5 mm to 10 mm.

  19. Influence of Different Patellofemoral Design Variations Based on Genesis II Total Knee Endoprosthesis on Patellofemoral Pressure and Kinematics.

    PubMed

    Leichtle, Ulf G; Lange, Barbara; Herzog, Yvonne; Schnauffer, Peter; Leichtle, Carmen I; Wülker, Nikolaus; Lorenz, Andrea

    2017-01-01

    In total knee arthroplasty (TKA), patellofemoral groove design varies greatly and likely has a distinct influence on patellofemoral biomechanics. To analyse the selective influence, five patellofemoral design variations were developed based on Genesis II total knee endoprosthesis (original design, being completely flat, being laterally elevated, being medially elevated, and both sides elevated) and made from polyamide using rapid prototyping. Muscle-loaded knee flexion was simulated on 10 human knee specimens using a custom-made knee simulator, measuring the patellofemoral pressure distribution and tibiofemoral and patellofemoral kinematics. The measurements were carried out in the native knee as well as after TKA with the 5 design prototypes. The overall influence of the different designs on the patellofemoral kinematics was small, but we found detectable effects for mediolateral tilt ( p < 0.05 for 35°-80° flexion) and translation of the patella ( p < 0.045 for 20°-65° and 75°-90°), especially for the completely flat design. Considering patellofemoral pressures, major interindividual differences were seen between the designs, which, on average, largely cancelled each other out. These results suggest that the elevation of the lateral margin of the patellofemoral groove is essential for providing mediolateral guidance, but smooth contouring as with original Genesis II design seems to be sufficient. The pronounced interindividual differences identify a need for more patellofemoral design options in TKA.

  20. The patient's experience of temporary paralysis from spinal anaesthesia, a part of total knee replacement.

    PubMed

    Bager, Louise; Konradsen, Hanne; Dreyer, Pia Sander

    2015-12-01

    The aim of this study was to describe the meaning of being temporary paralysed from spinal anaesthesia when undergoing total knee replacement. Total knee arthroplasty is a common procedure, and regional anaesthesia is used as a method for anaesthetising the patient. The experience is highly individual in substance and duration, and it can extend far beyond care settings as intraoperative care and the postanaesthesia care unit that have been investigated so far. A qualitative phenomenological hermeneutic design was chosen to gain a deeper understanding of the experience of spinal anaesthesia, as a part of having a total knee replacement. Twelve patients were interviewed in March 2014 after undergoing an elective total knee arthroplasty under spinal anaesthesia. The interviews were analysed with a Ricoeur-inspired interpretation method. Three themes were derived from the interviews: 'anaesthesia--an unavoidable necessity', 'an unrecognisable and incomprehensible body' and 'the body returns--joy and agony'. The results reveal that trust in the health care personnel and knowledge of the course of events play a key role in the experience. The trust can be breached by unforeseen events, or if the patient's experiences were not taken into account. The ability of the health care personnel to be in contact, share relevant knowledge with- and compensate for the patient is crucial in the prevention of negative experiences. The results of this study contribute to insights and deeper knowledge that can enhance staff's ability to provide care for patients undergoing total knee arthroplasty in spinal anaesthesia. The results provide perspectives that argue for care in accordance to individual needs. © 2015 John Wiley & Sons Ltd.

  1. Racial and Ethnic Differences in Total Knee Arthroplasty in the Veterans Affairs Health Care System, 2001-2013.

    PubMed

    Hausmann, Leslie R M; Brandt, Cynthia A; Carroll, Constance M; Fenton, Brenda T; Ibrahim, Said A; Becker, William C; Burgess, Diana J; Wandner, Laura D; Bair, Matthew J; Goulet, Joseph L

    2017-08-01

    To examine black-white and Hispanic-white differences in total knee arthroplasty from 2001 to 2013 in a large cohort of patients diagnosed with osteoarthritis (OA) in the Veterans Affairs (VA) health care system. Data were from the VA Musculoskeletal Disorders cohort, which includes data from electronic health records of more than 5.4 million veterans with musculoskeletal disorders diagnoses. We included white (non-Hispanic), black (non-Hispanic), and Hispanic (any race) veterans, age ≥50 years, with an OA diagnosis from 2001-2011 (n = 539,841). Veterans were followed from their first OA diagnosis until September 30, 2013. As a proxy for increased clinical severity, analyses were also conducted for a subsample restricted to those who saw an orthopedic or rheumatology specialist (n = 148,844). We used Cox proportional hazards regression to examine racial and ethnic differences in total knee arthroplasty by year of OA diagnosis, adjusting for age, sex, body mass index, physical and mental diagnoses, and pain intensity scores. We identified 12,087 total knee arthroplasty procedures in a sample of 473,170 white, 50,172 black, and 16,499 Hispanic veterans. In adjusted models examining black-white and Hispanic-white differences by year of OA diagnosis, total knee arthroplasty rates were lower for black than for white veterans diagnosed in all but 2 years. There were no Hispanic-white differences regardless of when diagnosis occurred. These patterns held in the specialty clinic subsample. Black-white differences in total knee arthroplasty appear to be persistent in the VA, even after controlling for potential clinical confounders. © 2016, American College of Rheumatology.

  2. Can a Silver-Coated Arthrodesis Implant Provide a Viable Alternative to Above Knee Amputation in the Unsalvageable, Infected Total Knee Arthroplasty?

    PubMed

    Wilding, Chris P; Cooper, George A; Freeman, Alexandra K; Parry, Michael C; Jeys, Lee

    2016-11-01

    In the unsalvageable, infected total knee arthroplasty, knee arthrodesis is one treatment option with lower reported reinfection rates compared with repeated 2-stage revision and improved function compared with amputation. One possible method for reducing incidence of recurrent infection treated by arthrodesis is the use of a silver-coated implant. We report our experience of silver-coated arthrodesis nails used for managing infected revision arthroplasty. We primarily assess the rate of reinfection and rate of amputation and report functional outcome measures. Retrospective analysis of all patients undergoing knee arthrodesis with a silver-coated arthrodesis nail between 2008 and 2014. Patient-reported data were recorded prearthrodesis and postarthrodesis (Oxford Knee Score and Short Form-36) as well as evidence of recurrent of infection, subsequent surgery, and the necessity for amputation. Eight patients underwent arthrodesis using the silver-coated arthrodesis nail. Mean duration of follow-up was 16 months (5-35 months). At the point of follow-up, there were no amputations, deaths, or implant revisions. One case of recurrent infection was successfully treated with washout and debridement. The mean prearthrodesis and postarthrodesis Oxford Knee Score difference was +8.9 points (P = .086) with significantly improved pain (P = .019), night pain (P = .021), and ease of standing (P = .003). Arthrodesis of the knee using a silver-coated intramedullary device is successful in eradicating infection and allowing limb conservation. Where infection does recur, this can be successfully treated with implant retention. The use of a silver-coated arthrodesis nail should be considered as an alternative to amputation for patients with a multiply revised and infected total knee arthroplasty. Copyright © 2016 Elsevier Inc. All rights reserved.

  3. Musculoskeletal multibody dynamics simulation of the contact mechanics and kinematics of a natural knee joint during a walking cycle.

    PubMed

    Hu, Jiayu; Chen, Zhenxian; Xin, Hua; Zhang, Qida; Jin, Zhongmin

    2018-05-01

    Detailed knowledge of the in vivo loading and kinematics in the knee joint is essential to understand its normal functions and the aetiology of osteoarthritis. Computer models provide a viable non-invasive solution for estimating joint loading and kinematics during different physiological activities. However, the joint loading and kinematics of the tibiofemoral and patellofemoral joints during a gait cycle were not typically investigated concurrently in previous computational simulations. In this study, a natural knee architecture was incorporated into a lower extremity musculoskeletal multibody dynamics model based on a force-dependent kinematics approach to investigate the contact mechanics and kinematics of a natural knee joint during a walking cycle. Specifically, the contact forces between the femoral/tibial articular cartilages and menisci and between the femoral and tibial/patellar articular cartilages were quantified. The contact forces and kinematics of the tibiofemoral and patellofemoral joints and the muscle activations and ligament forces were predicted simultaneously with a reasonable level of accuracy. The developed musculoskeletal multibody dynamics model with a natural knee architecture can serve as a potential platform for assisting clinical decision-making and postoperative rehabilitation planning.

  4. Utilization rates of knee-arthroplasty in OECD countries.

    PubMed

    Pabinger, C; Lothaller, H; Geissler, A

    2015-10-01

    The number of knee arthroplasties and the prevalence of obesity are increasing exponentially. To date there have been no published reviews on utilization rates of knee arthroplasty in OECD countries. We analysed economic, medical and population data relating to knee arthroplasty surgeries performed in OECD countries. Gross domestic product (GDP), health expenditures, obesity prevalence, knee arthroplasty utilization rates and growth in knee arthroplasty rates per 100,000 population were assessed for total population, for patients aged 65 years and over, and patients aged 64 years and younger. Obesity prevalence and utilization of knee arthroplasty have increased significantly in the past. The mean utilization rate of knee arthroplasty was 150 (22-235) cases per 100,000 total population in 2011. The strongest annual increase (7%) occurred in patients 64 years and under. Differences between individual countries can be explained by economic and medical patterns, with countries with higher medical expenditures and obesity prevalence having significantly higher utilization rates. Countries with lower utilization rates have significantly higher growth in utilization rates. The future demand for knee prostheses will increase x-fold by 2030, with exact rates dependant upon economic, social and medical factors. We observed a 10-fold variation in the utilization of knee arthroplasty among OECD countries. A significant and strong correlation of GDP, health expenditures and obesity prevalence with utilization of knee arthroplasty was found. Patients aged 64 years and younger show a two-fold higher growth rate in knee arthroplasty compared to the older population. This trend could result in a four-fold demand for knee arthroplasty in OECD countries by 2030. Copyright © 2015 Osteoarthritis Research Society International. Published by Elsevier Ltd. All rights reserved.

  5. Postoperative Knee Flexion Angle Is Affected by Lateral Laxity in Cruciate-Retaining Total Knee Arthroplasty.

    PubMed

    Nakano, Naoki; Matsumoto, Tomoyuki; Muratsu, Hirotsugu; Takayama, Koji; Kuroda, Ryosuke; Kurosaka, Masahiro

    2016-02-01

    Although many studies have reported that postoperative knee flexion is influenced by preoperative conditions, the factors which affect postoperative knee flexion have not been fully elucidated. We tried to investigate the influence of intraoperative soft tissue balance on postoperative knee flexion angle after cruciate-retaining (CR) total knee arthroplasty (TKA) using a navigation and an offset-type tensor. We retrospectively analyzed 55 patients with osteoarthritis who underwent TKA using e.motion-CR (B. Braun Aesculap, Germany) whose knee flexion angle could be measured at 2 years after operation. The exclusion criteria included valgus deformity, severe bony defect, infection, and bilateral TKA. Intraoperative varus ligament balance and joint component gap were measured with the navigation (Orthopilot 4.2; B. Braun Aesculap) while applying 40-lb joint distraction force at 0° to 120° of knee flexion using an offset-type tensor. Correlations between the soft tissue parameters and postoperative knee flexion angle were analyzed using simple linear regression models. Varus ligament balance at 90° of flexion (R = 0.56; P < .001) and lateral compartment gap at 90° of flexion (R = 0.51; P < .001) were positively correlated with postoperative knee flexion angle. In addition, as with past studies, joint component gap at 90° of flexion (R = 0.30; P < .05) and preoperative knee flexion angle (R = 0.63; P < .001) were correlated with postoperative knee flexion angle. Lateral laxity as well as joint component gap at 90° of flexion is one of the most important factors affecting postoperative knee flexion angle in CR-TKA. Copyright © 2016 Elsevier Inc. All rights reserved.

  6. Does patella position influence ligament balancing in total knee arthroplasty?

    PubMed

    Yoon, Jung-Ro; Oh, Kwang-Jun; Wang, Joon Ho; Yang, Jae-Hyuk

    2015-07-01

    In vivo comparative gap measurements were performed in three different patella positions (reduced, subluxated and everted) using offset-type-force-controlled-spreader-system. Prospectively, 50 knees were operated by total knee arthroplasty using a navigation-assisted gap-balancing technique. The offset-type-force-controlled-spreader-system was used for gap measurements. This commercially available instrument allows controllable tension in patella-reduced position. The mediolateral gaps of knee extension (0°) and flexion (90°) angle were recorded in three different patella positions; reduced, subluxated and everted. Any gap differences of more than 3 mm were considered as a meaningful difference. Correlation between the difference with the demographic data, preoperative radiologic alignment and intraoperative data was analysed. For statistical analysis, ANOVA and Pearson's correlation test were used. The gaps in patella eversion demonstrated smaller gaps both in knee extension and flexion position compared to the gaps of patella reduction position. The amount of decreased gaps was more definite in knee flexion position. Statistically significant difference was observed for the lateral gap of patella eversion compared to gap of patella reduction in knee flexion position (p < 0.05). There were notable cases of variability in knee flexion position. Significant portion of 12 (24 %) knees of patella subluxation and 33 (66 %) knees of patella evertion demonstrated either increased or decreased gaps in knee flexion position compared to the gaps of patella reduction position. The gaps in patella eversion demonstrated smaller gaps both in knee extension and flexion position compared to the gaps of patella reduction position. The amount of decreased gaps was more definite in knee flexion position. Therefore, the intraoperative patellar positioning has influence on the measurement of the joint gap. Keeping the patella in reduced position is important during gap balancing. I.

  7. Cross-sectional and Longitudinal Associations between Knee Joint Effusion Synovitis and Knee Pain in Older Adults.

    PubMed

    Wang, Xia; Jin, Xingzhong; Han, Weiyu; Cao, Yuelong; Halliday, Andrew; Blizzard, Leigh; Pan, Faming; Antony, Benny; Cicuttini, Flavia; Jones, Graeme; Ding, Changhai

    2016-01-01

    To describe the cross-sectional and longitudinal associations between knee regional effusion synovitis and knee pain in older adults. Data from a population-based random sample (n = 880, mean age 62 yrs, 50% women) were used. Baseline knee joint effusion synovitis was graded (0-3) using T2-weighted magnetic resonance imaging (MRI) in the suprapatellar pouch, central portion, posterior femoral recess, and subpopliteal recess. Effusion synovitis of the whole joint was defined as a score of ≥ 2 in any subregion. Other knee structural (including cartilage, bone marrow, and menisci) lesions were assessed by MRI at baseline. Knee pain was assessed by the Western Ontario and McMaster Universities Osteoarthritis Index questionnaire at baseline and 2.6 years later. Multivariable analyses were performed after adjustment for age, sex, body mass index, and other structural lesions. The prevalence of effusion synovitis was 67%. Suprapatellar pouch effusion synovitis was significantly and independently associated with increased total and nonweight-bearing knee pain in both cross-sectional and longitudinal analyses (for an increase in total knee pain of ≥ 5, RR 1.26 per grade, 95% CI 1.04-1.52), and increased weight-bearing knee pain in longitudinal analysis only. Effusion synovitis in posterior femoral recess and central portion were independently associated with increases in nonweight-bearing pain (RR 1.63 per grade, 95% CI 1.32-2.01 and RR 1.29 per grade, 95% CI 1.01-1.65, respectively) in longitudinal analyses only. Knee joint effusion synovitis has independent associations with knee pain in older adults. Suprapatellar pouch effusion synovitis is associated with nonweight-bearing and weight-bearing knee pain, while posterior femoral recess and central portion effusion synovitis are only associated with nonweight-bearing pain.

  8. Cementless total knee arthroplasty

    PubMed Central

    Risitano, Salvatore; Sabatini, Luigi; Giachino, Matteo; Agati, Gabriele; Massè, Alessandro

    2016-01-01

    Interest for uncemented total knee arthroplasty (TKA) has greatly increased in recent years. This technique, less used than cemented knee replacement in the last decades, sees a revival thanks an advance in prosthetic design, instrumentation and operative technique. The related literature in some cases shows conflicting data on survival and on the revision’s rate, but in most cases a success rate comparable to cemented TKA is reported. The optimal fixation in TKA is a subject of debate with the majority of surgeons favouring cemented fixation. PMID:27162779

  9. Quantification of in vivo implant wear in total knee replacement from dynamic single plane radiography

    NASA Astrophysics Data System (ADS)

    Teeter, Matthew G.; Seslija, Petar; Milner, Jaques S.; Nikolov, Hristo N.; Yuan, Xunhua; Naudie, Douglas D. R.; Holdsworth, David W.

    2013-05-01

    An in vivo method to measure wear in total knee replacements was developed using dynamic single-plane fluoroscopy. A dynamic, anthropomorphic total knee replacement phantom with interchangeable, custom-fabricated components of known wear volume was created, and dynamic imaging was performed. For each frame of the fluoroscopy data, the relative location of the femoral and tibial components were determined, and the apparent intersection of the femoral component with the tibial insert was used to calculate wear volume, wear depth, and frequency of intersection. No difference was found between the measured and true wear volumes. The precision of the measurements was ±39.7 mm3 for volume and ±0.126 mm for wear depth. The results suggest the system is capable of tracking wear volume changes across multiple time points in patients. As a dynamic technique, this method can provide both kinematic and wear measurements that may be useful for evaluating new implant designs for total knee replacements.

  10. [Interest of non invasive navigation in total knee arthroplasty].

    PubMed

    Zorman, D; Leclercq, G; Cabanas, J Juanos; Jennart, H

    2015-01-01

    During surgery of total knee arthroplasty, we use a computerized non invasive navigation (Brainlab Victor Vision CT-free) to assess the accuracy of the bone cuts (navigation expresse). The purpose of this study is to evaluate non invasive navigation when a total knee arthroplasty is achieved by conventional instrumentation. The study is based on forty total knee arthroplasties. The accuracy of the tibial and distal femoral bone cuts, checked by non invasive navigation, is evaluated prospectively. In our clinical series, we have obtained, with the conventional instrumentation, a correction of the mechanical axis only in 90 % of cases (N = 36). With non invasive navigation, we improved the positioning of implants and obtained in all cases the desired axiometry in the frontal plane. Although operative time is increased by about 15 minutes, the non invasive navigation does not induce intraoperative or immediate postoperative complications. Despite the cost of this technology, we believe that the reliability of the procedure is enhanced by a simple and reproducible technique.

  11. The AAHKS Clinical Research Award: Liposomal Bupivacaine and Periarticular Injection Are Not Superior to Single-Shot Intra-articular Injection for Pain Control in Total Knee Arthroplasty.

    PubMed

    Jain, Rajesh K; Porat, Manny D; Klingenstein, Greg G; Reid, Jeremy J; Post, Robert E; Schoifet, Scott D

    2016-09-01

    Intraoperative injections can help reduce early postoperative pain in total knee arthroplasty. We proposed that liposomal bupivacaine would not be superior to more common and cheaper injections. A single-blinded prospective randomized study with 207 consecutive patients was completed. Patients were randomized to treatment with periarticular liposomal bupivacaine injection, periarticular injection of bupivacaine/morphine, or intra-articular injection of bupivacaine/morphine at the conclusion of the procedure. Postoperative visual analog pain scores and narcotic consumption were recorded and analyzed. There was no significant difference in postoperative visual analog pain scores or narcotic consumption among the 3 study groups. Intra-articular injection of bupivacaine and morphine is as effective for postoperative pain control in total knee arthroplasty as periarticular bupivacaine/morphine injection and liposomal bupivacaine. Use of liposomal bupivacaine in total knee arthroplasty is costly and not justified. Copyright © 2016 Elsevier Inc. All rights reserved.

  12. Arthrodesis of the knee with a long intramedullary nail following the failure of a total knee arthroplasty as the result of infection. Surgical technique.

    PubMed

    Bargiotas, Konstantinos; Wohlrab, David; Sewecke, Jeffrey J; Lavinge, Gregory; DeMeo, Patrick J; Sotereanos, Nicholas G

    2007-03-01

    Knee arthrodesis can be an effective treatment option for relieving pain and restoring some function after the failure of a total knee arthroplasty as the result of infection. The purpose of the present study was to review the outcome of a staged approach for arthrodesis of the knee with a long intramedullary nail after the failure of a total knee arthroplasty as the result of infection. We reviewed the results for twelve patients who underwent knee arthrodesis after the removal of a prosthesis because of infection. The study group included seven women and five men who had an average age of sixty-eight years at the time of the arthrodesis. All patients were managed with a staged protocol. Implant removal, débridement, and insertion of antibiotic cement spacers was followed by the administration of systemic antibiotics. Provided that clinical and laboratory data suggested eradication of the infection, arthrodesis of the affected knee with use of a long intramedullary nail was carried out. Clinical and laboratory evaluation and radiographic analysis were performed after an average duration of follow-up of 4.1 years. Solid union was achieved in ten of the twelve knees. The average time to union was 5.5 months. One patient had an above-the-knee amputation because of recurrence of infection. In another patient, nail breakage occurred three years following implantation. The average limb-length discrepancy was 5.5 cm. The mean Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) score improved from 41 to 64 points. None of the seven patients who underwent arthrodesis with a technique involving convex-to-concave reamers had a complication, and the average time to union for these seven patients was shorter than that for the remaining five patients (4.3 compared with 7.4 months). We believe that obtaining large surfaces of bleeding contact bone during arthrodesis following staged treatment of an infection at the site of a failed total knee arthroplasty contributes to stability and enhances bone-healing. Staged arthrodesis with use of a long intramedullary nail and convex-to-concave preparation of bone ends provided a painless functional gait with low complication and reoperation rates in this challenging group of patients.

  13. Arthrodesis of the knee with a long intramedullary nail following the failure of a total knee arthroplasty as the result of infection.

    PubMed

    Bargiotas, Konstantinos; Wohlrab, David; Sewecke, Jeffrey J; Lavinge, Gregory; Demeo, Patrick J; Sotereanos, Nicholas G

    2006-03-01

    Knee arthrodesis can be an effective treatment option for relieving pain and restoring some function after the failure of a total knee arthroplasty as the result of infection. The purpose of the present study was to review the outcome of a staged approach for arthrodesis of the knee with a long intramedullary nail after the failure of a total knee arthroplasty as the result of infection. We reviewed the results for twelve patients who underwent knee arthrodesis after the removal of a prosthesis because of infection. The study group included seven women and five men who had an average age of sixty-eight years at the time of the arthrodesis. All patients were managed with a staged protocol. Implant removal, débridement, and insertion of antibiotic cement spacers was followed by the administration of systemic antibiotics. Provided that clinical and laboratory data suggested eradication of the infection, arthrodesis of the affected knee with use of a long intramedullary nail was carried out. Clinical and laboratory evaluation and radiographic analysis were performed after an average duration of follow-up of 4.1 years. Solid union was achieved in ten of the twelve knees. The average time to union was 5.5 months. One patient had an above-the-knee amputation because of recurrence of infection. In another patient, nail breakage occurred three years following implantation. The average limb-length discrepancy was 5.5 cm. The mean Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) score improved from 41 to 64 points. None of the seven patients who underwent arthrodesis with a technique involving convex-to-concave reamers had a complication, and the average time to union for these seven patients was shorter than that for the remaining five patients (4.3 compared with 7.4 months). We believe that obtaining large surfaces of bleeding contact bone during arthrodesis following staged treatment of an infection at the site of a failed total knee arthroplasty contributes to stability and enhances bone-healing. Staged arthrodesis with use of a long intramedullary nail and convex-to-concave preparation of bone ends provided a painless functional gait with low complication and reoperation rates in this challenging group of patients.

  14. The Influence of Minimalist Footwear on Knee and Ankle Load during Depth Jumping.

    PubMed

    Sinclair, J; Hobbs, S J; Selfe, J

    2015-01-01

    Plyometric training is used by athletes to promote strength and explosive power. However plyometric activities such as depth jumping are associated with a high incidence of injuries. This study examined the influence of minimalist and conventional footwear on the loads experienced by the patellofemoral joint and Achilles tendon. Patellofemoral and Achilles tendon forces were obtained from ten male participants using an eight-camera 3D motion capture system and force platform data as they completed depth jumps in both footwear conditions. Differences between footwear were calculated using paired t-tests. The results show that the minimalist footwear were associated with significantly lower patellofemoral contact force/pressure and also knee abduction moment. It is therefore recommended, based on these observations, that those who are susceptible to knee pain should consider minimalist footwear when performing plyometric training.

  15. Impact of Tranexamic Acid in Total Knee and Total Hip Replacement.

    PubMed

    Boyle, Jaclyn A; Soric, Mate M

    2017-02-01

    To evaluate the net clinical benefit of tranexamic acid use in patients undergoing total knee or total hip replacement. This is a retrospective study of patients undergoing total knee or total hip replacement. The primary outcome was the net clinical benefit of tranexamic acid use. Secondary outcomes included length of stay, incidence of venous thromboembolism, change in hemoglobin, and number of units of blood transfused. Four hundred and six patients were screened for inclusion and 327 patients met inclusion criteria; 174 patients received tranexamic acid versus 153 patients who received usual care. Tranexamic acid demonstrated a positive net clinical benefit versus usual care (40.8% vs 13.7%, P < .01) but did not affect length of stay (3.39 vs 3.37 days, respectively, P = .76). Venous thromboembolism was comparable between groups (2.3% vs 0.7%, P = .38). Average change in hemoglobin and need for transfusion were lower in the treatment group versus the usual care group, respectively (3.46 vs 4.26 mg/dL, P < .01). Tranexamic acid demonstrated a significant benefit in decreasing change in hemoglobin as well as the need for blood transfusion with no increase in the risk of venous thromboembolism in patients undergoing total knee or total hip replacement.

  16. Reconstruction of the extensor mechanism with fresh-frozen tendon allograft in total knee arthroplasty.

    PubMed

    Llombart Blanco, Rafael; Valentí, Andrés; Díaz de Rada, Pablo; Mora, Gonzalo; Valentí, Juan R

    2014-11-01

    Patellar tendon rupture after total knee replacement is a rare and highly limiting injury with multifactorial aetiology. Many reconstruction techniques have been described with not very predictable results. The use of allografts has been accepted as a suitable solution. A series of seven patients with patellar tendon rupture treated with fresh-frozen tendon allograft reconstruction after knee arthroplasty is presented. Median follow-up is 25 months (20-31). Functional assessment improved, and the knee society score and knee functional score improved from 26 and 16 to 82 and 55, respectively. Median extension lag was 5° (0°-20°), with a median range of motion of 95° (70-100). Radiological study showed a rise of the patella of 22.26 mm. The use of fresh-frozen allografts as a solution to patellar tendon ruptures after knee arthroplasty seems to provide acceptable results. Increased patellar height does not seem to affect functionality. Case series, Level IV.

  17. Clinical, objective, and functional outcomes of manipulation under anesthesia to treat knee stiffness following total knee arthroplasty.

    PubMed

    Issa, Kimona; Kapadia, Bhaveen H; Kester, Mark; Khanuja, Harpal S; Delanois, Ronald E; Mont, Michael A

    2014-03-01

    The purpose of this study was to determine the clinical outcomes of manipulation under anesthesia (MUA) in a cohort who had developed knee stiffness following total knee arthroplasty (TKA). One-hundred and forty-five TKAs in 134 patients who had undergone MUA were compared to the remaining 1973 TKAs in 1671 patients who did not develop this condition. At a mean follow-up of 51 months (range, 24 to 85 months), the mean gains in flexion in the MUA cohort were 33° (range, 5° to 65°). The final range-of-motion in the MUA cohort was lower than the comparison cohort (114° versus 125°) however, this would meet the required flexion for activities of daily living. There were no differences in the Knee Society objective and functional scores between the two cohorts. It is encouraging that MUA cohort outcomes were comparable to outcomes of patients who did not develop knee stiffness. © 2014.

  18. Load balance in total knee arthroplasty: an in vitro analysis.

    PubMed

    El-Hawary, Ron; Roth, Sandra E; King, Graham J W; Chess, David G; Johnson, James A

    2006-09-01

    One of the goals of total knee arthroplasty (TKA) is to balance the loads between the compartments of the knee. An instrumented load cell that measures compartment loads in real time is utilized to evaluate conventional, qualitative methods of achieving this balance. TKA was performed on 10 cadaveric knees. Prior to and after load balancing, compartment forces were measured at flexion angles of 0-90 degrees. Knees were randomly assigned into one of two groups, based upon whether or not the surgeons could visualize the load cell's output during balancing. Prior to attempting load balance, there were significant differences between the medial and lateral compartment loads for all knees (p < 0.05). After attempting balance with the aid of the load cell, there was equal load balance at all angles studied. Without the aid of the load cell, balance was not consistently achieved at every angle. Conventional load balancing techniques in TKA are not perfect. Copyright 2006 John Wiley & Sons, Ltd.

  19. Impact of obesity and knee osteoarthritis on morbidity and mortality in older Americans.

    PubMed

    Losina, Elena; Walensky, Rochelle P; Reichmann, William M; Holt, Holly L; Gerlovin, Hanna; Solomon, Daniel H; Jordan, Joanne M; Hunter, David J; Suter, Lisa G; Weinstein, Alexander M; Paltiel, A David; Katz, Jeffrey N

    2011-02-15

    Obesity and knee osteoarthritis are among the most frequent chronic conditions affecting Americans aged 50 to 84 years. To estimate quality-adjusted life-years lost due to obesity and knee osteoarthritis and health benefits of reducing obesity prevalence to levels observed a decade ago. The U.S. Census and obesity data from national data sources were combined with estimated prevalence of symptomatic knee osteoarthritis to assign persons aged 50 to 84 years to 4 subpopulations: nonobese without knee osteoarthritis (reference group), nonobese with knee osteoarthritis, obese without knee osteoarthritis, and obese with knee osteoarthritis. The Osteoarthritis Policy Model, a computer simulation model of knee osteoarthritis and obesity, was used to estimate quality-adjusted life-year losses due to knee osteoarthritis and obesity in comparison with the reference group. United States. U.S. population aged 50 to 84 years. Quality-adjusted life-years lost owing to knee osteoarthritis and obesity. Estimated total losses of per-person quality-adjusted life-years ranged from 1.857 in nonobese persons with knee osteoarthritis to 3.501 for persons affected by both conditions, resulting in a total of 86.0 million quality-adjusted life-years lost due to obesity, knee osteoarthritis, or both. Quality-adjusted life-years lost due to knee osteoarthritis and/or obesity represent 10% to 25% of the remaining quality-adjusted survival of persons aged 50 to 84 years. Hispanic and black women had disproportionately high losses. Model findings suggested that reversing obesity prevalence to levels seen 10 years ago would avert 178,071 cases of coronary heart disease, 889,872 cases of diabetes, and 111,206 total knee replacements. Such a reduction in obesity would increase the quantity of life by 6,318,030 years and improve life expectancy by 7,812,120 quality-adjusted years in U.S. adults aged 50 to 84 years. Comorbidity incidences were derived from prevalence estimates on the basis of life expectancy of the general population, potentially resulting in conservative underestimates. Calibration analyses were conducted to ensure comparability of model-based projections and data from external sources. The number of quality-adjusted life-years lost owing to knee osteoarthritis and obesity seems to be substantial, with black and Hispanic women experiencing disproportionate losses. Reducing mean body mass index to the levels observed a decade ago in this population would yield substantial health benefits. The National Institutes of Health and the Arthritis Foundation.

  20. Best multimodal analgesic protocol for total knee arthroplasty.

    PubMed

    Webb, Christopher A J; Mariano, Edward R

    2015-01-01

    Total knee arthroplasty is one of the most commonly performed operations in the USA. As with any elective joint surgery, the primary goal includes functional restoration that is not limited by pain. The use of peripheral nerve blocks for patients undergoing knee arthroplasty has resulted in decreased pain scores, improved early ambulation and decreased time to achieve hospital discharge criteria. Concern has been raised over the potential risks of femoral nerve block, and there has been growing support for the adductor canal block. It is the author's opinion that when not contraindicated, intraoperative neuraxial anesthesia combined with a continuous adductor canal block and a multimodal medication regimen for postoperative pain control is the best analgesic protocol for knee arthroplasty.

  1. Patella Tendon Injuries Secondary to Cement Spacers Used at First-Stage Revision of Infected Total Knee Replacement

    PubMed Central

    Wilson, Katherine; Kothwal, Rahul; Khan, Wasim S.; Williams, Rhodri; Morgan-Jones, Rhidian

    2015-01-01

    We describe a series of three patients who sustained patella tendon injuries in infected total knee arthroplasties following the use of a static cement spacer at first-stage knee revision. The patella tendon injuries resulted in significant compromise to wound healing and knee stability requiring multiple surgeries. The mid-term function was poor with an Oxford score at 24 months ranging from 12 to 20. Based on our experience, we advise caution in the use of static cement spacer blocks. If they are to be used, we recommend that they should be keyed in the bone to prevent patella tendon injuries. PMID:25905106

  2. Sciatic nerve block causing heel ulcer after total knee replacement in 36 patients.

    PubMed

    Todkar, Manoj

    2005-12-01

    Femoral and sciatic nerve blocks are often used for postoperative analgesia following total knee replacement surgery. In this report, we focus on cases of heel ulcers which occurred following the implementation of peripheral nerve block in concert with knee replacement surgery. In some instances, heel ulcers have resulted in delayed rehabilitation and prolonged hospital stays in this group of patients, which makes this phenomenon a potential burden on the healthcare system. Pressure points in the foot should be protected after the implementation of nerve blocks to prevent pressure sores. An awareness of this unusual complication related to knee replacement surgery is necessary to prevent its occurrence and avoid delays in patient rehabilitation and recovery.

  3. Knee arthrodesis – ultima ratio for the treatment of the infected knee

    PubMed Central

    Tiemann, Andreas H. H.

    2013-01-01

    The irretrievable destruction of the knee due to trauma, tumor or infection is the indication for knee arthrodesis. The main reason for knee arthrodesis in terms of infection ist the infected total knee arthroplasty. Central problem is the definition of the term “irretrievable”. It is based on the subjective opinion of the attending physician and depends on his expert knowledge of this specific entity. The preservation of a functioning extremity is the main goal. This article shows the typical indications and contraindications for knee arthrodesis following septic knee diseases. In addition it gives insight into the biomechanical and technical considerations to be kept in mind. Finally the postoperative care and outcome of different techniques are analysed. PMID:26504699

  4. Knee arthrodesis.

    PubMed

    MacDonald, James H; Agarwal, Sanjeev; Lorei, Matthew P; Johanson, Norman A; Freiberg, Andrew A

    2006-03-01

    Arthrodesis is one of the last options available to obtain a stable, painless knee in a patient with a damaged knee joint that is not amenable to reconstructive measures. Common indications for knee arthrodesis include failed total knee arthroplasty, periarticular tumor, posttraumatic arthritis, and chronic sepsis. The primary contraindications to knee fusion are bilateral involvement or an ipsilateral hip arthrodesis. A variety of techniques has been described, including external fixation, internal fixation by compression plates, intramedullary fixation through the knee with a modular nail, and antegrade nailing through the piriformis fossa. Allograft or autograft may be necessary to restore lost bone stock or to augment fusion. For the carefully selected patient with realistic expectations, knee arthrodesis may relieve pain and obviate the need for additional surgery or extensive postoperative rehabilitation.

  5. Posterior Cruciate Ligament Retention versus Posterior Stabilization for Total Knee Arthroplasty: A Meta-Analysis.

    PubMed

    Jiang, Chao; Liu, Zhenlei; Wang, Ying; Bian, Yanyan; Feng, Bin; Weng, Xisheng

    2016-01-01

    Although being debated for many years, the superiority of posterior cruciate-retaining (CR) total knee arthroplasty (TKA) and posterior-stabilized (PS) TKA remains controversial. We compare the knee scores, post-operative knee range of motion (ROM), radiological outcomes about knee kinematic and complications between CR TKA and PS TKA. Literature published up to August 2015 was searched in PubMed, Embase and Cochrane databases, and meta-analysis was performed using the software, Review Manager version 5.3. Totally 14 random control trials (RCTs) on this topic were included for the analysis, which showed that PS and CR TKA had no significant difference in Knee Society knee Score (KSS), pain score (KSPS), Hospital for Special Surgery score (HSS), kinematic characteristics including postoperative component alignment, tibial posterior slope and joint line, and complication rate. However, PS TKA is superior to CR TKA regarding post-operative knee range of motion (ROM) [Random Effect model (RE), Mean Difference (MD) = -7.07, 95% Confidential Interval (CI) -10.50 to -3.65, p<0.0001], improvement of ROM (Fixed Effect model (FE), MD = -5.66, 95% CI -10.79 to -0.53, p = 0.03) and femoral-tibial angle [FE, MD = 0.85, 95% CI 0.46 to 1.25, p<0.0001]. There are no clinically relevant differences between CR and PS TKA in terms of clinical, functional, radiological outcome, and complications, while PS TKA is superior to CR TKA in respects of ROM, while whether this superiority matters or not in clinical practice still needs further investigation and longer follow-up.

  6. Early outcomes of twin-peg mobile-bearing unicompartmental knee arthroplasty compared with primary total knee arthroplasty.

    PubMed

    Lum, Z C; Lombardi, A V; Hurst, J M; Morris, M J; Adams, J B; Berend, K R

    2016-10-01

    Since redesign of the Oxford phase III mobile-bearing unicompartmental knee arthroplasty (UKA) femoral component to a twin-peg design, there has not been a direct comparison to total knee arthroplasty (TKA). Thus, we explored differences between the two cohorts. A total of 168 patients (201 knees) underwent medial UKA with the Oxford Partial Knee Twin-Peg. These patients were compared with a randomly selected group of 177 patients (189 knees) with primary Vanguard TKA. Patient demographics, Knee Society (KS) scores and range of movement (ROM) were compared between the two cohorts. Additionally, revision, re-operation and manipulation under anaesthesia rates were analysed. The mean follow-up for UKA and TKA groups was 5.4 and 5.5 years, respectively. Six TKA (3.2%) versus three UKAs (1.5%) were revised which was not significant (p = 0.269). Manipulation was more frequent after TKA (16; 8.5%) versus none in the UKA group (p < 0.001). UKA patients had higher post-operative KS function scores versus TKA patients (78 versus 66, p < 0.001) with a trend toward greater improvement, but there was no difference in ROM and KS clinical improvement (p = 0.382 and 0.420, respectively). We found fewer manipulations, and higher functional outcomes for patients treated with medial mobile-bearing UKA compared with TKA. TKA had twice the revision rate as UKA although this did not reach statistical significance with the numbers available. Cite this article: Bone Joint J 2016;98-B(10 Suppl B):28-33. ©2016 Berend et al.

  7. Pseudoaneurysm of the superior lateral genicular artery: case report of a rare complication after total knee arthroplasty

    PubMed Central

    2013-01-01

    Background Pseudoaneurysm of superior lateral genicular artery following total knee arthroplasty is a rare complication and has been reported following lateral release performed for eversion of patella in a knee with tight lateral structures. Case presentation This report describes a case of pseudo aneurysm of superior lateral geniculate artery that developed after primary Total knee arthroplasty for a stiff knee in a 68 year old patient. Patient presented with pain and rapidly increasing swelling in early post operative period. Diagnosis was made on duplex ultrasound and confirmed by angiography. Angiographic coil embolisation of the pseudoaneurysm was performed. Since no lateral release was performed in this case, the probable mechanism was shear injury to the vessel. Conclusion Pseudoaneurysm of superior lateral genicular artery can occur in absence of lateral release by shear injury to an atherosclerotic vessel. Angiographic coil embolisation appears to be the best method for treating such post arthroplasty pseudoaneurysm because of less chance of infection, non interference with rehabilitation and diagnosis and treatment during same procedure. PMID:23687974

  8. Correlations between commonly used clinical outcome scales and patient satisfaction after total knee arthroplasty.

    PubMed

    Kwon, Sae Kwang; Kang, Yeon Gwi; Kim, Sung Ju; Chang, Chong Bum; Seong, Sang Cheol; Kim, Tae Kyun

    2010-10-01

    Patient satisfaction is becoming increasingly important as a crucial outcome measure for total knee arthroplasty. We aimed to determine how well commonly used clinical outcome scales correlate with patient satisfaction after total knee arthroplasty. In particular, we sought to determine whether patient satisfaction correlates better with absolute postoperative scores or preoperative to 12-month postoperative changes. Patient satisfaction was evaluated using 4 grades (enthusiastic, satisfied, noncommittal, and disappointed) for 438 replaced knees that were followed for longer than 1 year. Outcomes scales used the American Knee Society, Western Ontario McMaster University Osteoarthritis Index scales, and Short Form-36 scores. Correlation analyses were performed to investigate the relation between patient satisfaction and the 2 different aspects of the outcome scales: postoperative scores evaluated at latest follow-ups and preoperative to postoperative changes. The Western Ontario McMaster University Osteoarthritis Index scales function score was most strongly correlated with satisfaction (correlation coefficient=0.45). Absolute postoperative scores were better correlated with satisfaction than the preoperative to postoperative changes for all scales. Level IV (retrospective case series). Copyright © 2010 Elsevier Inc. All rights reserved.

  9. Assessment and validation of CT scanogram to compare per-operative and post-operative mechanical axis after navigated total knee replacement

    PubMed Central

    Jain, Sunil

    2008-01-01

    Our objective was to assess and validate low-dose computed tomography (CT) scanogram as a post-operative imaging modality to measure the mechanical axis after navigated total knee replacement. A prospective study was performed to compare intra-operative and post-operative mechanical axis after navigated total knee replacements. All consecutive patients who underwent navigated total knee replacement between May and December 2006 were included. The intra-operative final axis was recorded, and post-operatively a CT scanogram of lower limbs was performed. The mechanical axis was measured and compared against the intra-operative measurement. There were 15 patients ranging in age from 57 to 80 (average 70) years. The average final intra-operative axis was 0.56° varus (4° varus to 1.5° valgus) and post-operative CT scanogram axis was 0.52° varus (3.1° varus to 1.8° valgus). The average deviation from final axes to CT scanogram axes was 0.12° valgus with a correlation coefficient of 0.9. Our study suggests that CT scanogram is an imaging modality with reasonable accuracy for measuring mechanical axis despite significantly low radiation. It also confirms a high level of correlation between intra-operative and post-operative mechanical axis after navigated total knee replacement. PMID:18696064

  10. Manipulation for stiffness following total knee arthroplasty: when and how often to do it?

    PubMed

    Desai, Aravind S; Karmegam, Anand; Dramis, Asterios; Board, Tim N; Raut, Videsh

    2014-10-01

    Stiffness following total knee arthroplasty is a disabling complication. One of the management options of stiffness includes manipulation under anaesthesia, but no real consensus exist on appropriate timing of intervention, and the timing and results of the manipulation under anaesthesia (MUA) are under debate in the literature. Our aim was to determine the efficacy of single and multiple manipulations under anaesthesia following total knee arthroplasty and to determine the most appropriate timing for manipulation. We retrospectively reviewed 86 patients who underwent manipulation for stiffness following primary total knee replacement with at least 1-year follow-up. Range of motion before surgery, at the time of the MUA, immediately after MUA and at 6 weeks and 1 year post-MUA were recorded. At the end of 1 year post-manipulation, manipulations performed at less than 20 weeks, following primary total knee arthroplasty, showed 31° of flexion gain as compared to only 1.5° of flexion gain when manipulation was undertaken after 20 weeks. Of the 86 patients, 21 had multiple manipulations with no significant difference in flexion gain after the second manipulation. Patients on warfarin (26%) had an increased incidence of stiffness and poor flexion gain. This study showed that better results were achieved when manipulation was performed at less than 20 weeks (particularly between 12 and 14 weeks) from primary surgery with no added benefit from re-manipulations.

  11. Modular Polyethylene Inserts for Total Knee Arthroplasty: Can Surgeons Detect 1-mm Thickness Increments?

    PubMed

    Yoo, Joanne Y; Cai, Jenny; Chen, Antonia F; Austin, Matthew S; Sharkey, Peter F

    2016-05-01

    Some manufacturers have introduced polyethylene (PE) inserts in 1-mm increment thickness options to allow for finer adjustments in total knee arthroplasty kinematics. Two surgeons with extensive experience performed 88 total knee arthroplasties using implants with 1-mm PE inserts. After trial components were inserted and the optimal PE thickness was selected, the insert was removed and a trial insert size was randomly chosen from opaque envelopes (1-mm smaller, same size, and 1-mm larger). The knee was re-examined and the surgeon determined which size PE had been placed. Surgeons reliably determined insert thicknesses in 62.5% (55 of 88; P = .050) of trials. Surgeons were not able to accurately detect 1-mm incremental changes of trial PE implants on a consistent basis. The potential clinical usefulness of this concept should be further evaluated. Copyright © 2016 Elsevier Inc. All rights reserved.

  12. Preservation of kinematics with posterior cruciate-, bicruciate- and patient-specific bicruciate-retaining prostheses in total knee arthroplasty by using computational simulation with normal knee model

    PubMed Central

    Koh, Y-G.; Son, J.; Kwon, S-K.; Kim, H-J.; Kang, K-T.

    2017-01-01

    Objectives Preservation of both anterior and posterior cruciate ligaments in total knee arthroplasty (TKA) can lead to near-normal post-operative joint mechanics and improved knee function. We hypothesised that a patient-specific bicruciate-retaining prosthesis preserves near-normal kinematics better than standard off-the-shelf posterior cruciate-retaining and bicruciate-retaining prostheses in TKA. Methods We developed the validated models to evaluate the post-operative kinematics in patient-specific bicruciate-retaining, standard off-the-shelf bicruciate-retaining and posterior cruciate-retaining TKA under gait and deep knee bend loading conditions using numerical simulation. Results Tibial posterior translation and internal rotation in patient-specific bicruciate-retaining prostheses preserved near-normal kinematics better than other standard off-the-shelf prostheses under gait loading conditions. Differences from normal kinematics were minimised for femoral rollback and internal-external rotation in patient-specific bicruciate-retaining, followed by standard off-the-shelf bicruciate-retaining and posterior cruciate-retaining TKA under deep knee bend loading conditions. Moreover, the standard off-the-shelf posterior cruciate-retaining TKA in this study showed the most abnormal performance in kinematics under gait and deep knee bend loading conditions, whereas patient-specific bicruciate-retaining TKA led to near-normal kinematics. Conclusion This study showed that restoration of the normal geometry of the knee joint in patient-specific bicruciate-retaining TKA and preservation of the anterior cruciate ligament can lead to improvement in kinematics compared with the standard off-the-shelf posterior cruciate-retaining and bicruciate-retaining TKA. Cite this article: Y-G. Koh, J. Son, S-K. Kwon, H-J. Kim, O-R. Kwon, K-T. Kang. Preservation of kinematics with posterior cruciate-, bicruciate- and patient-specific bicruciate-retaining prostheses in total knee arthroplasty by using computational simulation with normal knee model. Bone Joint Res 2017;6:557–565. DOI: 10.1302/2046-3758.69.BJR-2016-0250.R1. PMID:28947604

  13. Short-term outcome of 1,465 computer-navigated primary total knee replacements 2005-2008.

    PubMed

    Gøthesen, Oystein; Espehaug, Birgitte; Havelin, Leif; Petursson, Gunnar; Furnes, Ove

    2011-06-01

    and purpose Improvement of positioning and alignment by the use of computer-assisted surgery (CAS) might improve longevity and function in total knee replacements, but there is little evidence. In this study, we evaluated the short-term results of computer-navigated knee replacements based on data from the Norwegian Arthroplasty Register. Primary total knee replacements without patella resurfacing, reported to the Norwegian Arthroplasty Register during the years 2005-2008, were evaluated. The 5 most common implants and the 3 most common navigation systems were selected. Cemented, uncemented, and hybrid knees were included. With the risk of revision for any cause as the primary endpoint and intraoperative complications and operating time as secondary outcomes, 1,465 computer-navigated knee replacements (CAS) and 8,214 conventionally operated knee replacements (CON) were compared. Kaplan-Meier survival analysis and Cox regression analysis with adjustment for age, sex, prosthesis brand, fixation method, previous knee surgery, preoperative diagnosis, and ASA category were used. Kaplan-Meier estimated survival at 2 years was 98% (95% CI: 97.5-98.3) in the CON group and 96% (95% CI: 95.0-97.8) in the CAS group. The adjusted Cox regression analysis showed a higher risk of revision in the CAS group (RR = 1.7, 95% CI: 1.1-2.5; p = 0.02). The LCS Complete knee had a higher risk of revision with CAS than with CON (RR = 2.1, 95% CI: 1.3-3.4; p = 0.004)). The differences were not statistically significant for the other prosthesis brands. Mean operating time was 15 min longer in the CAS group. With the introduction of computer-navigated knee replacement surgery in Norway, the short-term risk of revision has increased for computer-navigated replacement with the LCS Complete. The mechanisms of failure of these implantations should be explored in greater depth, and in this study we have not been able to draw conclusions regarding causation.

  14. Continuous passive motion and its effects on knee flexion after total knee arthroplasty in patients with knee osteoarthritis.

    PubMed

    Liao, Chun-De; Huang, Yi-Ching; Lin, Li-Fong; Chiu, Yen-Shuo; Tsai, Jui-Chen; Chen, Chun-Lung; Liou, Tsan-Hon

    2016-08-01

    This study evaluated the effects of continuous passive motion (CPM) on accelerated flexion after total knee arthroplasty (TKA) and whether CPM application measures (i.e. initial angle and daily increment) are associated with functional outcomes. A retrospective investigation was conducted at the rehabilitation centre of a university-based teaching hospital. Patients who received CPM therapy immediately after TKA surgery were categorized into rapid-, normal-, and slow-progress groups according to their response to CPM during their acute inpatient stay. Knee pain, passive knee flexion, and knee function-measured using the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC)-were assessed preoperatively at discharge and at 3- and 6-month outpatient follow-up visits. A total of 354 patients were followed for 6 months after inpatient-stay discharge. The patients in the rapid-progress group (n = 119) exhibited significantly greater knee flexions than those in the slow-progress group did (n = 103) at the 3-month follow-up [mean difference (MD) = 10.3°, 95 % confidence interval (CI) 4.3°-16.3°, p < 0.001] and 6-month follow-up (MD = 10.9°, 95 % CI 6.3°-15.6°, p < 0.001). Significant WOMAC score differences between the rapid- and slow-progress groups were observed at the 3-month follow-up (MD = 7.2, 95 % CI 5.4-9.1, p < 0.001) and 6-month follow-up (MD = 16.1, 95 % CI 13.4-18.7, p < 0.001). CPM initial angles and rapid progress significantly predicted short- and long-term outcomes in knee flexion and WOMAC scores (p < 0.001). When CPM is used, early application with initial high flexion and rapid progress benefits knee function up to 6 months after TKA. II.

  15. Does preoperative physiotherapy improve postoperative, patient-based outcomes in older adults who have undergone total knee arthroplasty? A systematic review.

    PubMed

    Chesham, Ross Alexander; Shanmugam, Sivaramkumar

    2017-01-01

    Knee osteoarthritis (OA) is a leading cause of disability in older adults (≥60) in the UK. If nonsurgical management fails and if OA severity becomes too great, knee arthroplasty is a preferred treatment choice. Preoperative physiotherapy is often offered as part of rehabilitation to improve postoperative patient-based outcomes. Systematically review whether preoperative physiotherapy improves postoperative, patient-based outcomes in older adults who have undergone total knee arthroplasty (TKA) and compare study interventions to best-practice guidelines. A literature search of Randomized Controlled Trials (RCTs), published April 2004-April 2014, was performed across six databases. Individual studies were evaluated for quality using the PEDro Scale. Ten RCTs met the full inclusion/exclusion criteria. RCTs compared control groups versus: preoperative exercise (n = 5); combined exercise and education (n = 2); combined exercise and acupuncture (n = 1); neuromuscular electrical stimulation (NMES; n = 1); and acupuncture versus exercise (n = 1). RCTs recorded many patient-based outcomes including knee strength, ambulation, and pain. Minimal evidence is presented that preoperative physiotherapy is more effective than no physiotherapy or usual care. PEDro Scale and critical appraisal highlighted substantial methodological quality issues within the RCTs. There is insufficient quality evidence to support the efficacy of preoperative physiotherapy in older adults who undergo total knee arthroplasty.

  16. Clinical Evaluation of the Root Tear of the Posterior Horn of the Medial Meniscus in Total Knee Arthroplasty for Osteoarthritis.

    PubMed

    Choi, Eui-Sung; Park, Sang-Jun

    2015-06-01

    To investigate the incidence of root tears of the posterior horn of the medial meniscus in total knee replacement arthroplasty for knee osteoarthritis and retrospectively analyze clinical results and factors associated with root tears. There were 197 knees of 140 enrolled patients who had undergone total knee replacement arthroplasty between September 2010 and May 2014. The presence of a root tear of the posterior horn of the medial meniscus was confirmed in all patients. Statistical analysis was performed to investigate the correlation between root tears and the possible factors of meniscal tears including gender, age, severity of symptoms (visual analogue scale [VAS] score and medial joint line tenderness), grade of osteoarthritis (Kellgren-Lawrence grading scale), body mass index (BMI), varus deformity, and mechanical axis deviation. Meniscal tears were observed in 154 knees (78.17%). The root tear had correlation with the severity of osteoarthritis (p<0.05), varus deformity (p<0.05), mechanical axis deviation (p<0.05), and BMI (p<0.05). Factors considered to represent the severity of osteoarthritis were found to be associated with root tears of the medial meniscus posterior horn. Increased BMI seemed to be associated with the increased incidence of root tears of the medial meniscus posterior horn.

  17. Reliability and concurrent validity of the Dutch hip and knee replacement expectations surveys

    PubMed Central

    2010-01-01

    Background Preoperative expectations of outcome of total hip and knee arthroplasty are important determinants of patients' satisfaction and functional outcome. Aims of the study were (1) to translate the Hospital for Special Surgery Hip Replacement Expectations Survey and Knee Replacement Expectations Survey into Dutch and (2) to study test-retest reliability and concurrent validity. Methods Patients scheduled for total hip (N = 112) or knee replacement (N = 101) were sent the Dutch Expectations Surveys twice with a 2 week interval to determine test-retest reliability. To determine concurrent validity, the Expectation WOMAC was sent. Results The results for the Dutch Hip Replacement Expectations Survey revealed good test-retest reliability (ICC 0.87), no bias and good internal consistency (alpha 0.86) (N = 72). The correlation between the Hip Expectations Score and the Expectation WOMAC score was 0.59 (N = 86). The results for the Dutch Knee Replacement Expectations Survey revealed good test-retest reliability (ICC 0.79), no bias and good internal consistency (alpha 0.91) (N = 46). The correlation with the Expectation WOMAC score was 0.52 (N = 57). Conclusions Both Dutch Expectations Surveys are reliable instruments to determine patients' expectations before total hip or knee arthroplasty. As for concurrent validity, the correlation between both surveys and the Expectation WOMAC was moderate confirming that the same construct was determined. However, patients scored systematically lower on the Expectation WOMAC compared to the Dutch Expectation Surveys. Research on patients' expectations before total hip and knee replacement has only been performed in a limited amount of countries. With the Dutch Expectations Surveys it is now possible to determine patients' expectations in another culture and healthcare setting. PMID:20958990

  18. Reliability and concurrent validity of the Dutch hip and knee replacement expectations surveys.

    PubMed

    van den Akker-Scheek, Inge; van Raay, Jos J A M; Reininga, Inge H F; Bulstra, Sjoerd K; Zijlstra, Wiebren; Stevens, Martin

    2010-10-19

    Preoperative expectations of outcome of total hip and knee arthroplasty are important determinants of patients' satisfaction and functional outcome. Aims of the study were (1) to translate the Hospital for Special Surgery Hip Replacement Expectations Survey and Knee Replacement Expectations Survey into Dutch and (2) to study test-retest reliability and concurrent validity. Patients scheduled for total hip (N = 112) or knee replacement (N = 101) were sent the Dutch Expectations Surveys twice with a 2 week interval to determine test-retest reliability. To determine concurrent validity, the Expectation WOMAC was sent. The results for the Dutch Hip Replacement Expectations Survey revealed good test-retest reliability (ICC 0.87), no bias and good internal consistency (alpha 0.86) (N = 72). The correlation between the Hip Expectations Score and the Expectation WOMAC score was 0.59 (N = 86). The results for the Dutch Knee Replacement Expectations Survey revealed good test-retest reliability (ICC 0.79), no bias and good internal consistency (alpha 0.91) (N = 46). The correlation with the Expectation WOMAC score was 0.52 (N = 57). Both Dutch Expectations Surveys are reliable instruments to determine patients' expectations before total hip or knee arthroplasty. As for concurrent validity, the correlation between both surveys and the Expectation WOMAC was moderate confirming that the same construct was determined. However, patients scored systematically lower on the Expectation WOMAC compared to the Dutch Expectation Surveys. Research on patients' expectations before total hip and knee replacement has only been performed in a limited amount of countries. With the Dutch Expectations Surveys it is now possible to determine patients' expectations in another culture and healthcare setting.

  19. Open-Label Milnacipran for Patients With Persistent Knee Pain 1 Year or Longer After Total Knee Arthroplasty: A Pilot Study

    PubMed Central

    Bolognesi, Michael P.

    2013-01-01

    Objective: The current study investigates whether milnacipran is effective in reducing pain and improving function in patients with persistent pain ≥ 1 year after total knee arthroplasty. Method: This was a 12-week open-label study of flexibly dosed milnacipran in patients (N = 5) experiencing chronic persistent knee pain ≥ 1 year following total knee arthroplasty in the absence of new injury, infection, or implant failure. Subjects were identified from October 2010 to August 2011 through the Duke University Medical Center orthopedic clinic (Durham, North Carolina), typically during 1-year postoperative follow-up visits, and were referred by their orthopedic surgeon. Results: Milnacipran treatment was associated with reduction in pain according to the primary outcome measure of the visual analog scale (VAS) score for pain (effect size of 1.15) and secondary outcome measures of Knee Society Score (KSS) evaluation subscale score (effect size of 1.37) and Medical Outcomes Study 36-item Short-Form Health Survey (SF-36) bodily pain subscale (effect size of 1.16) at week 12. Secondary outcome measures of functional change were mixed in such that, at week 12, the SF-36 physical functioning subscale showed improvement (effect size of 1.16), but the KSS function subscale score was just below the threshold for meaningful effect size (0.98). Conclusions: Open-label milnacipran demonstrated reduced pain and some evidence of functional improvement in this small sample of patients with chronic persistent pain 1 year or more after total knee arthroplasty such that well-powered studies are warranted. Trial Registration: ClinicalTrials.gov identifier: NCT01780389 PMID:24392250

  20. The Influence of Component Alignment and Ligament Properties on Tibiofemoral Contact Forces in Total Knee Replacement.

    PubMed

    Smith, Colin R; Vignos, Michael F; Lenhart, Rachel L; Kaiser, Jarred; Thelen, Darryl G

    2016-02-01

    The study objective was to investigate the influence of coronal plane alignment and ligament properties on total knee replacement (TKR) contact loads during walking. We created a subject-specific knee model of an 83-year-old male who had an instrumented TKR. The knee model was incorporated into a lower extremity musculoskeletal model and included deformable contact, ligamentous structures, and six degrees-of-freedom (DOF) tibiofemoral and patellofemoral joints. A novel numerical optimization technique was used to simultaneously predict muscle forces, secondary knee kinematics, ligament forces, and joint contact pressures from standard gait analysis data collected on the subject. The nominal knee model predictions of medial, lateral, and total contact forces during gait agreed well with TKR measures, with root-mean-square (rms) errors of 0.23, 0.22, and 0.33 body weight (BW), respectively. Coronal plane component alignment did not affect total knee contact loads, but did alter the medial-lateral load distribution, with 4 deg varus and 4 deg valgus rotations in component alignment inducing +17% and -23% changes in the first peak medial tibiofemoral contact forces, respectively. A Monte Carlo analysis showed that uncertainties in ligament stiffness and reference strains induce ±0.2 BW uncertainty in tibiofemoral force estimates over the gait cycle. Ligament properties had substantial influence on the TKR load distributions, with the medial collateral ligament and iliotibial band (ITB) properties having the largest effects on medial and lateral compartment loading, respectively. The computational framework provides a viable approach for virtually designing TKR components, considering parametric uncertainty and predicting the effects of joint alignment and soft tissue balancing procedures on TKR function during movement.

  1. The Influence of Component Alignment and Ligament Properties on Tibiofemoral Contact Forces in Total Knee Replacement

    PubMed Central

    Smith, Colin R.; Vignos, Michael F.; Lenhart, Rachel L.; Kaiser, Jarred; Thelen, Darryl G.

    2016-01-01

    The study objective was to investigate the influence of coronal plane alignment and ligament properties on total knee replacement (TKR) contact loads during walking. We created a subject-specific knee model of an 83-year-old male who had an instrumented TKR. The knee model was incorporated into a lower extremity musculoskeletal model and included deformable contact, ligamentous structures, and six degrees-of-freedom (DOF) tibiofemoral and patellofemoral joints. A novel numerical optimization technique was used to simultaneously predict muscle forces, secondary knee kinematics, ligament forces, and joint contact pressures from standard gait analysis data collected on the subject. The nominal knee model predictions of medial, lateral, and total contact forces during gait agreed well with TKR measures, with root-mean-square (rms) errors of 0.23, 0.22, and 0.33 body weight (BW), respectively. Coronal plane component alignment did not affect total knee contact loads, but did alter the medial–lateral load distribution, with 4 deg varus and 4 deg valgus rotations in component alignment inducing +17% and −23% changes in the first peak medial tibiofemoral contact forces, respectively. A Monte Carlo analysis showed that uncertainties in ligament stiffness and reference strains induce ±0.2 BW uncertainty in tibiofemoral force estimates over the gait cycle. Ligament properties had substantial influence on the TKR load distributions, with the medial collateral ligament and iliotibial band (ITB) properties having the largest effects on medial and lateral compartment loading, respectively. The computational framework provides a viable approach for virtually designing TKR components, considering parametric uncertainty and predicting the effects of joint alignment and soft tissue balancing procedures on TKR function during movement. PMID:26769446

  2. Success rates for initial eradication of peri-prosthetic knee infection treated with a two-stage procedure.

    PubMed

    Kaminski, Andrzej; Citak, Mustafa; Schildhauer, Thomas Armin; Fehmer, Tobias

    2014-01-01

    In Germany, rates of primary total knee arthroplasty procedures and exchange arthroplasty procedures continue to rise. Late-onset peri-prosthetic infection constitutes a serious complication whose management may be dependent upon the spectrum of micro-organisms involved. The aim of this study was to provide a retrospective analysis of the effectiveness of initial eradication measures performed as part of a two-stage procedure. Between 2002 and 2008, a total of 328 patients who had received a first-time diagnosis of chronic peri-prosthetic knee infection following total knee arthroplasty (TKA) subsequently underwent surgery at our clinic. The surgical approach consisted of a two-stage procedure, with the initial procedure consisting of the removal of the prosthesis and radical debridement, followed by insertion of an antibiotic-loaded static spacer. The effectiveness of the procedure was assessed after six weeks, with each patient undergoing a number of clinical and laboratory-based tests, including knee joint aspiration. Staphylococcus aureus strains were responsible for 68% (n=223) of the total number of cases of peri-prosthetic knee infection. 19% of cases (n=62) showed evidence of gram-negative bacteria, while MRSA accounted for 15% (n=49) of cases. Six weeks after completion of the above-named treatment regimen, eradication of infection was considered successful in 289 patients (88.1%). Eradication was unsuccessful in 22% of MRSA infections (n=11) and 7% of MSSA infections (n=23). The treatment regimen outlined in this report is capable of achieving satisfactory results in the management of late-onset peri-prosthetic knee infection, with one exception: patients with infections caused by MRSA showed high failure rates.

  3. Hip Abductor Strengthening Improves Physical Function Following Total Knee Replacement: One-Year Follow-Up of a Randomized Pilot Study.

    PubMed

    Harikesavan, Karvannan; Chakravarty, Raj D; Maiya, Arun G; Hegde, Sanjay P; Y Shivanna, Shivakumar

    2017-01-01

    Total knee replacement (TKR) is the commonest surgical procedure for patients with severe pain and impaired physical function following end stage knee osteoarthritis. The hip abductors are well renowned in stabilization of the trunk and hip during walking, maintaining the lower limb position, and transferring the forces from the lower limbs to the pelvis. To assess the efficacy of hip abductor strengthening exercise on functional outcome using performance based outcome measures following total knee replacement. An observer blinded randomized pilot trial design was conducted at Manipal hospital, Bangalore, India. Participants designated for elective TKR were randomized to experimental group hip abductor strengthening along with standard rehabilitation (n=10) or control group standard rehabilitation alone (n=10). Participants followed for one year to assess physical function using performance based outcomes, such as timed up and go test, single leg stance test, six minute walk test, knee extensor strength and hip abductor strength. Eighteen participants with a mean age of 63.1 ± 5.5 years (8 Males and 10 Females) completed the study. Improvement in hip abduction strength, single leg stand test was superior in hip abductor strengthening group at 3 months and 1 year when compared to standard rehabilitation alone. Hip abductor strengthening showed superior improvements in single leg stance test and six minute walk test. Hip abductor strengthening exercises has the potential to improve physical function following total knee replacement.

  4. Five-year results of a randomised controlled trial comparing mobile and fixed bearings in total knee replacement.

    PubMed

    Breeman, S; Campbell, M K; Dakin, H; Fiddian, N; Fitzpatrick, R; Grant, A; Gray, A; Johnston, L; MacLennan, G S; Morris, R W; Murray, D W

    2013-04-01

    There is conflicting evidence about the merits of mobile bearings in total knee replacement, partly because most randomised controlled trials (RCTs) have not been adequately powered. We report the results of a multicentre RCT of mobile versus fixed bearings. This was part of the knee arthroplasty trial (KAT), where 539 patients were randomly allocated to mobile or fixed bearings and analysed on an intention-to-treat basis. The primary outcome measure was the Oxford Knee Score (OKS) plus secondary measures including Short Form-12, EuroQol EQ-5D, costs, cost-effectiveness and need for further surgery. There was no significant difference between the groups pre-operatively: mean OKS was 17.18 (sd 7.60) in the mobile-bearing group and 16.49 (sd 7.40) in the fixed-bearing group. At five years mean OKS was 33.19 (sd 16.68) and 33.65 (sd 9.68), respectively. There was no significant difference between trial groups in OKS at five years (-1.12 (95% confidence interval -2.77 to 0.52) or any of the other outcome measures. Furthermore, there was no significant difference in the proportion of patients with knee-related re-operations or in total costs. In this appropriately powered RCT, over the first five years after total knee replacement functional outcomes, re-operation rates and healthcare costs appear to be the same irrespective of whether a mobile or fixed bearing is used.

  5. Hip Abductor Strengthening Improves Physical Function Following Total Knee Replacement: One-Year Follow-Up of a Randomized Pilot Study

    PubMed Central

    Harikesavan, Karvannan; Chakravarty, Raj D.; Maiya, Arun G; Hegde, Sanjay P.; Y. Shivanna, Shivakumar

    2017-01-01

    Background: Total knee replacement (TKR) is the commonest surgical procedure for patients with severe pain and impaired physical function following end stage knee osteoarthritis. The hip abductors are well renowned in stabilization of the trunk and hip during walking, maintaining the lower limb position, and transferring the forces from the lower limbs to the pelvis. Objective: To assess the efficacy of hip abductor strengthening exercise on functional outcome using performance based outcome measures following total knee replacement. Methods: An observer blinded randomized pilot trial design was conducted at Manipal hospital, Bangalore, India. Participants designated for elective TKR were randomized to experimental group hip abductor strengthening along with standard rehabilitation (n=10) or control group standard rehabilitation alone (n=10). Participants followed for one year to assess physical function using performance based outcomes, such as timed up and go test, single leg stance test, six minute walk test, knee extensor strength and hip abductor strength. Result: Eighteen participants with a mean age of 63.1 ± 5.5 years (8 Males and 10 Females) completed the study. Improvement in hip abduction strength, single leg stand test was superior in hip abductor strengthening group at 3 months and 1 year when compared to standard rehabilitation alone. Conclusion: Hip abductor strengthening showed superior improvements in single leg stance test and six minute walk test. Hip abductor strengthening exercises has the potential to improve physical function following total knee replacement. PMID:28567148

  6. Randomized trial investigating the efficacy of manual lymphatic drainage to improve early outcome after total knee arthroplasty.

    PubMed

    Ebert, Jay R; Joss, Brendan; Jardine, Berit; Wood, David J

    2013-11-01

    To investigate the efficacy of manual lymphatic drainage (MLD) in the early postoperative period after total knee arthroplasty (TKA) to reduce edema and pain and improve knee range of motion. Prospective randomized controlled trial. Private hospital and functional rehabilitation clinic. Consecutive sample of patients (N=43; 53 knees) scheduled for TKA. MLD (vs no MLD) on days 2, 3, and 4 postoperatively. Both groups underwent conventional, concomitant physical therapy. Clinical assessment was undertaken pre- and postoperatively prior to and after the designated postoperative MLD sessions (days 2, 3, and 4) and at 6 weeks postsurgery. This included active knee flexion and extension range of motion, lower limb girths (ankle, midpatella, thigh, and calf), and knee pain using a numeric rating scale and the Knee Injury and Osteoarthritis Outcome Score. A significant group effect was observed for active knee flexion, with post hoc tests demonstrating a significantly greater active knee flexion in the MLD group when compared with the control (no MLD) group at the final measure prior to hospital discharge (day 4 postsurgery) and at 6 weeks postsurgery. There were no further group effects observed for the remaining patient-reported and functional outcomes. MLD in the early postoperative stages after TKA appears to improve active knee flexion up to 6 weeks postsurgery, in addition to conventional care. Copyright © 2013 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  7. Wear Behavior of an Unstable Knee: Stabilization via Implant Design?

    PubMed Central

    Reinders, Jörn; Kretzer, Jan Philippe

    2014-01-01

    Background. Wear-related failures and instabilities are frequent failure mechanisms of total knee replacements. High-conforming designs may provide additional stability for the joint. This study analyzes the effects of a ligamentous insufficiency on the stability and the wear behavior of a high-conforming knee design. Methods. Two simulator wear tests were performed on a high-conforming total knee replacement design. In the first, a ligamentous-stable knee replacement with a sacrificed anterior cruciate ligament was simulated. In the second, a ligamentous-unstable knee with additionally insufficient posterior cruciate ligament and medial collateral ligament was simulated. Wear was determined gravimetrically and wear particles were analyzed. Implant kinematics was recorded during simulation. Results. Significantly higher wear rates (P ≤ 0.001) were observed for the unstable knee (14.58 ± 0.56 mg/106 cycles) compared to the stable knee (7.97 ± 0.87 mg/106 cycles). A higher number of wear particles with only small differences in wear particle characteristics were observed. Under unstable knee conditions, kinematics increased significantly for translations and rotations (P ≤ 0.01). This increase was mainly attributed to higher tibial posterior translation and internal rotations. Conclusion. Higher kinematics under unstable test conditions is a result of insufficient stabilization via implant design. Due to the higher kinematics, increased wear was observed in this study. PMID:25276820

  8. The Relationship Between Early-Stage Knee Osteoarthritis and Lower-Extremity Alignment, Joint Laxity, and Subjective Scores of Pain, Stiffness, and Function.

    PubMed

    Hicks-Little, Charlie A; Peindl, Richard D; Hubbard-Turner, Tricia J; Cordova, Mitchell L

    2016-08-01

    Knee osteoarthritis (OA) is a debilitating disease that affects an estimated 27 million Americans. Changes in lower-extremity alignment and joint laxity have been found to redistribute the medial and/or lateral loads at the joint. However, the effect that changes in anteroposterior knee-joint laxity have on lower-extremity alignment and function in individuals with knee OA remains unclear. To examine anteroposterior knee-joint laxity, lower-extremity alignment, and subjective pain, stiffness, and function scores in individuals with early-stage knee OA and matched controls and to determine if a relationship exists among these measures. Case control. Sports-medicine research laboratory. 18 participants with knee OA and 18 healthy matched controls. Participants completed the Western Ontario McMaster (WOMAC) osteoarthritis questionnaire and were tested for total anteroposterior knee-joint laxity (A-P) and knee-joint alignment (ALIGN). WOMAC scores, A-P (mm), and ALIGN (°). A significant multivariate main effect for group (Wilks' Λ = 0.30, F7,26 = 8.58, P < .0001) was found. Knee-OA participants differed in WOMAC scores (P < .0001) but did not differ from healthy controls on ALIGN (P = .49) or total A-P (P = .66). No significant relationships were identified among main outcome measures. These data demonstrate that participants with early-stage knee OA had worse pain, stiffness, and functional outcome scores than the matched controls; however, ALIGN and A-P were no different. There was no association identified among participants' subjective scores, ALIGN, or A-P measures in this study.

  9. A 3D finite element model to investigate prosthetic interface stresses of different posterior tibial slope.

    PubMed

    Shen, Yi; Li, Xiaomiao; Fu, Xiaodong; Wang, Weili

    2015-11-01

    Posterior tibial slope that is created during proximal tibial resection in total knee arthroplasty has emerged as an important factor in the mechanics of the knee joint and the surgical outcome. But the ideal degree of posterior tibial slope for recovery of the knee joint function and preventions of complications remains controversial and should vary in different racial groups. The objective of this paper is to investigate the effects of posterior tibial slope on contact stresses in the tibial polyethylene component of total knee prostheses. Three-dimensional finite element analysis was used to calculate contact stresses in tibial polyethylene component of total knee prostheses subjected to a compressive load. The 3D finite element model of total knee prosthesis was constructed from the images produced by 3D scanning technology. Stresses in tibial polyethylene component were calculated with four different posterior tibial slopes (0°, 3°, 6° and 9°). The 3D finite element model of total knee prosthesis we presented was well validated. We found that the stress distribution in the polythene as evaluated by the distributions of the von Mises stress, the maximum principle stress, the minimum principle stress and the Cpress were more uniform with 3° and 6° posterior tibial slopes than with 0° and 9° posterior tibial slopes. Moreover, the peaks of the above stresses and trends of changes with increasing degree of knee flexion were more ideal with 3° and 6° posterior slopes. The results suggested that the tibial component inclination might be favourable to 7°-10° so far as the stress distribution is concerned. The range of the tibial component inclination also can decrease the wear of polyethylene. Chinese posterior tibial slope is bigger than in the West, and the current domestic use of prostheses is imported from the West, so their demands to tilt back bone cutting can lead to shorten the service life of prostheses; this experiment result is of important clinical significance, guiding orthopaedic surgeon after the best angle to cut bone.

  10. Early Patient Outcomes After Primary Total Knee Arthroplasty with Quadriceps-Sparing Subvastus and Medial Parapatellar Techniques

    PubMed Central

    Tomek, Ivan M.; Kantor, Stephen R.; Cori, LuAnne A.; Scoville, Jennifer M.; Grove, Margaret R.; Morgan, Tamara S.; Swarup, Ishaan; Moschetti, Wayne E.; Spratt, Kevin F.

    2014-01-01

    Background: Techniques that reduce injury to the knee extensor mechanism may cause less pain and allow faster recovery of knee function after primary total knee arthroplasty. A quadriceps-sparing (QS) subvastus technique of total knee arthroplasty was compared with medial parapatellar arthrotomy (MPPA) to determine which surgical technique led to better patient-reported function and less postoperative pain and opioid utilization. Methods: In this prospective, double-blind study, 129 patients undergoing total knee arthroplasty were randomized to the QS or the MPPA group after skin incision. All surgical procedures utilized minimally invasive surgery principles and standardized anesthesia, implants, analgesia, and rehabilitation. The Knee Society Score (KSS) was obtained at baseline and one and three months after surgery. Weekly telephone interviews were used to collect patient-reported outcomes including ambulatory device use, the UCLA (University of California Los Angeles) activity score, performance of daily living activities, and opioid utilization. Results: No differences between groups were seen in opioid utilization, either during the acute hospitalization or in the eight weeks after surgery. The QS group reported significantly less pain at rest on postoperative day one and with activity on day three (p = 0.04 for each). Compared with baseline, both groups showed significant improvements in the KSS at one month (MPPA, p = 0.0278; QS, p = 0.0021) and three months (p < 0.0001 for each) as well as week-to-week gains in walking independence through five weeks after surgery. Independence from ambulatory devices outside the home lagged behind independence indoors by about two weeks in both groups. Conclusions: When primary total knee arthroplasty was performed with contemporary minimally invasive surgery principles and standardized implants, anesthesia, and postoperative pathways, the QS technique yielded no significant early functional advantages or differences in opioid utilization compared with the MPPA technique. However, the mean pain scores reported by patients in the QS group were slightly lower at rest on postoperative day one and during activity on day three. Level of Evidence: Therapeutic Level I. See Instructions for Authors for a complete description of levels of evidence. PMID:24897738

  11. [Application of tibial mechanical axis locator in tibial extra-articular deformity in total knee arthroplasty].

    PubMed

    Li, Guoliang; Han, Guangpu; Zhang, Jinxiu; Ma, Shiqiang; Guo, Donghui; Yuan, Fulu; Qi, Bingbing; Shen, Runbin

    2013-07-01

    To explore the application value of self-made tibial mechanical axis locator in tibial extra-articular deformity in total knee arthroplasty (TKA) for improving the lower extremity force line. Between January and August 2012, 13 cases (21 knees) of osteoarthritis with tibial extra-articular deformity were treated, including 5 males (8 knees) and 8 females (13 knees) with an average age of 66.5 years (range, 58-78 years). The disease duration was 2-5 years (mean, 3.5 years). The knee society score (KSS) was 45.5 +/- 15.5. Extra-articular deformities included 1 case of knee valgus (2 knees) and 12 cases of knee varus (19 knees). Preoperative full-length X-ray films of lower extremities showed 10-21 degrees valgus or varus deformity of tibial extra joint. Self-made tibial mechanical axis locator was used to determine and mark coronal tibial mechanical axis under X-ray before TKA, and then osteotomy was performed with extramedullary positioning device according to the mechanical axis marker.' All incisions healed by first intention, without related complications of infection and joint instability. All patients were followed up 5-12 months (mean, 8.3 months). The X-ray examination showed < 2 degrees knee deviation angle in the others except 1 case of 2.9 degrees knee deviation angle at 3 days after operation, and the accurate rate was 95.2%. No loosening or instability of prosthesis occurred during follow-up. KSS score was 85.5 +/- 15.0 at last follow-up, showing significant difference when compared with preoperative score (t=12.82, P=0.00). The seft-made tibial mechanical axis locator can improve the accurate rate of the lower extremity force line in TKA for tibia extra-articular deformity.

  12. Position controlled Knee Rehabilitation Orthotic Device for Patients after Total Knee Replacement Arthroplasty

    NASA Astrophysics Data System (ADS)

    Wannaphan, Patsiri; Chanthasopeephan, Teeranoot

    2016-11-01

    Knee rehabilitation after total knee replacement arthroplasty is essential for patients during their post-surgery recovery period. This study is about designing one degree of freedom knee rehabilitation equipment to assist patients for their post-surgery exercise. The equipment is designed to be used in sitting position with flexion/extension of knee in sagittal plane. The range of knee joint motion is starting from 0 to 90 degrees angle for knee rehabilitation motion. The feature includes adjustable link for different human proportions and the torque feedback control at knee joint during rehabilitation and the control of flexion/extension speed. The motion of the rehabilitation equipment was set to move at low speed (18 degrees/sec) for knee rehabilitation. The rehabilitation link without additional load took one second to move from vertical hanging up to 90° while the corresponding torque increased from 0 Nm to 2 Nm at 90°. When extra load is added, the link took 1.5 seconds to move to 90° The torque is then increased from 0 Nm to 4 Nm. After a period of time, the speed of the motion can be varied. User can adjust the motion to 40 degrees/sec during recovery activity of the knee and users can increase the level of exercise or motion up to 60 degrees/sec to strengthen the muscles during throughout their rehabilitation program depends on each patient. Torque control is included to prevent injury. Patients can use the equipment for home exercise to help reduce the number of hospital visit while the patients can receive an appropriate therapy for their knee recovery program.

  13. Long-term results of total knee arthroplasty for valgus knees: soft-tissue release technique and implant selection.

    PubMed

    Rajgopal, Ashok; Dahiya, Vivek; Vasdev, Attique; Kochhar, Hemanshu; Tyagi, Vipin

    2011-04-01

    To report long-term results of total knee arthroplasty (TKA) for valgus knees. 34 women and 19 men aged 39 to 84 (mean, 74) years with valgus knees underwent primary TKA by a senior surgeon. Of the 78 knees, 43, 29, and 6 had type-I, type-II, and type-III valgus deformities, respectively. A preliminary lateral soft-tissue release was performed, and the tibia and femur were prepared. The tight lateral structures were released using the pie-crusting technique. In 92% of the knees, cruciate-retaining implants were used. In knees with severe deformity and medial collateral ligament insufficiency, the posterior cruciate ligament was sacrificed and constrained implants were used. The Hospital for Special Surgery (HSS) knee score was assessed, as were tibiofemoral alignment, range of motion, stability, and evidence of loosening or osteolysis. Patients were followed up for 8 to 14 (mean, 10) years. All knees had a good patellar position and were clinically stable in both mediolateral and anteroposterior planes. No radiolucency was noted. The mean HSS knee score improved from 48 to 91 (p<0.001). The mean tibiofemoral alignment improved from valgus 20 to 5 degrees (p<0.001). The mean range of motion improved from 65 to 110 degrees (p<0.001). One patient developed a deep infection at year 4, and 2 had periprosthetic fractures at years 6 and 8. Adequate lateral soft-tissue release is the key to successful TKAs in valgus knees. The choice of implant depends on the severity of the valgus deformity and the extent of soft-tissue release needed to obtain a stable, balanced flexion and extension gap, in order to achieve minimal constraint with maximum stability.

  14. Knee fusion--a new technique using an old Belgian surgical approach and a new intramedullary nail.

    PubMed

    Alt, V; Seligson, D

    2001-02-01

    Knee arthrodesis is a useful procedure in difficult cases such as failed total knee arthroplasty, severe articular trauma, bone tumors, and infected knee joints. The most common techniques for knee fusion include external fixation and intramedullary nailing. Küntscher's nail is driven antegrade from the intertrochanteric region into the knee. We describe a new technique for knee arthrodesis using a new intramedullary nail and an old Belgian surgical approach to the knee joint published by Lambotte in 1913. This approach provides excellent exposure for the implantation of the nail by osteotomizing the patella vertically. The nail is implanted using HeyGroves method, whereby the nail is inserted retrograde into the femur and pulled distally anterograde into the tibia. We now use this technique as our standard procedure for knee fusion.

  15. Knee loading inhibits osteoclast lineage in a mouse model of osteoarthritis

    PubMed Central

    Li, Xinle; Yang, Jing; Liu, Daquan; Li, Jie; Niu, Kaijun; Feng, Shiqing; Yokota, Hiroki; Zhang, Ping

    2016-01-01

    Osteoarthritis (OA) is a whole joint disorder that involves cartilage degradation and periarticular bone response. Changes of cartilage and subchondral bone are associated with development and activity of osteoclasts from subchondral bone. Knee loading promotes bone formation, but its effects on OA have not been well investigated. Here, we hypothesized that knee loading regulates subchondral bone remodeling by suppressing osteoclast development, and prevents degradation of cartilage through crosstalk of bone-cartilage in osteoarthritic mice. Surgery-induced mouse model of OA was used. Two weeks application of daily dynamic knee loading significantly reduced OARSI scores and CC/TAC (calcified cartilage to total articular cartilage), but increased SBP (subchondral bone plate) and B.Ar/T.Ar (trabecular bone area to total tissue area). Bone resorption of osteoclasts from subchondral bone and the differentiation of osteoclasts from bone marrow-derived cells were completely suppressed by knee loading. The osteoclast activity was positively correlated with OARSI scores and negatively correlated with SBP and B.Ar/T.Ar. Furthermore, knee loading exerted protective effects by suppressing osteoclastogenesis through Wnt signaling. Overall, osteoclast lineage is the hyper responsiveness of knee loading in osteoarthritic mice. Mechanical stimulation prevents OA-induced cartilage degeneration through crosstalk with subchondral bone. Knee loading might be a new potential therapy for osteoarthritis patients. PMID:27087498

  16. Therapeutic embolization of the genicular arteries for recurrent hemarthrosis after total knee arthroplasty.

    PubMed

    Katsimihas, M; Robinson, D; Thornton, M; Langkamer, V G

    2001-10-01

    The case of a recurrent hemarthrosis initially presenting 30 months after a total knee arthroplasty in a patient on lifelong warfarin is described. Angiography was used to aid in the diagnosis, and therapeutic selective embolization of the superior genicular arteries was performed with satisfactory clinical results.

  17. Functional outcomes of outpatient balance training following total knee replacement in patients with knee osteoarthritis: a randomized controlled trial.

    PubMed

    Liao, Chun-De; Lin, Li-Fong; Huang, Yi-Ching; Huang, Shih-Wei; Chou, Lin-Chuan; Liou, Tsan-Hon

    2015-09-01

    To evaluate whether balance training after total knee replacement surgery improves functional outcomes and to determine whether postoperative balance is associated with mobility. A prospective intervention study and randomized controlled trial with an intention-to-treat analysis. The rehabilitation center of a university-based teaching hospital. A total of 130 patients with knee osteoarthritis who had undergone total knee replacement surgery were recruited to attend an outpatient rehabilitation program. They were randomly allocated to additional balance rehabilitation and functional rehabilitation groups. During the eight-week outpatient rehabilitation program, both groups received general functional training. Patients in the balance rehabilitation group received an additional balance-based rehabilitation program. The functional reach test, single-leg stance test, 10-m walk test, Timed Up and Go Test, timed chair-stand test, stair-climb test, and Western Ontario and McMaster Universities Osteoarthritis Index were measured at baseline, eight weeks (T(1)), and 32 weeks (T(2)). The balance rehabilitation group patients demonstrated significant improvement in the results of the functional reach test at T(1) (37.6 ±7.8 cm) and T(2) (39.3 ±9.7 cm) compared with the baseline assessment (11.5 ±2.9 cm) and Timed Up and Go Test at T(1) (8.9 ±1.2 seconds) and T(2) (8.0 ±1.9 seconds) compared with the baseline assessment (12.5 ±1.8 seconds). Moreover, the balance rehabilitation group patients exhibited significantly greater improvements in balance and mobility than did the functional rehabilitation group patients (all P < 0.001). Furthermore, improved balance was significantly associated with improved mobility at T(2). Postoperative outpatient rehabilitation with balance training improves the balance, mobility, and functional outcomes in patients with knee osteoarthritis after total knee replacement. © The Author(s) 2014.

  18. Knee effusion after total knee replacement.

    PubMed Central

    Cameron, H. U.

    1993-01-01

    The various causes of effusions in artificial knees can be divided into four groups: implant related, technique related, interface problems, and infection. Diagnosis can be made from the patient's history and a clinical examination. Treatment is usually surgical revision. Images Figure 1 p1110-a Figure 5 Figure 6 Figure 7 PMID:8499791

  19. Current surgical strategies for total arthroplasty in valgus knee

    PubMed Central

    Nikolopoulos, Dimitrios; Michos, Ioannis; Safos, George; Safos, Petros

    2015-01-01

    The majority of orthopaedic surgeons even currently agree that primary total arthroplasty in valgus knees with a deformity of more than ten degrees may prove challenging. The unique sets of bone and soft tissue abnormalities that must be addressed at the time of the operation make accurate axis restoration, component orientation and joint stability attainment a difficult task. Understanding the specific pathologic anatomic changes associated with the valgus knee is a prerequisite so as to select the proper surgical method, to optimize component position and restore soft-tissue balance. The purpose of this article is to review the valgus knee anatomical variations, to assess the best pre-operative planning and to evaluate how to choose the grade of constraint of the implant. It will also be underlying the up-to-date main approaches and surgical techniques be proposed in the English literature both for bone cuts and soft tissue management of valgus knees. PMID:26191494

  20. Novel Technique: Knee Arthrodesis Using Trabecular Metal Cones with Intramedullary Nailing and Intramedullary Autograft.

    PubMed

    Peterson, Blake E; Bal, Sonny; Aggarwal, Ajay; Crist, Brett D

    2016-08-01

    The failed total knee arthroplasty is a challenge to the surgeon and the patient. Infection, bone loss, and instability lead to a chronically painful and dysfunctional limb. Two-stage revision arthroplasty has been successful in clearing a majority of periprosthetic joint infections. However, there are many cases when the multiply revised and infected total knee arthroplasty cannot be salvaged. We report, a review of knee arthrodesis and a novel technique to manage significant bone loss. The use of trabecular metal cones and a long intramedullary nail can be used in concert with an autologous intramedullary bone graft to provide a stable, length restoring construct with sufficient biology to heal very large bone voids. With this technique we have successfully restored function and stability in the failed knee arthroplasty. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  1. Two-staged Bilateral, Femoral Alignment Osteotomy with Concomitant Total Knee Arthroplasty in an Achondroplasia Patient - A Case Report

    PubMed Central

    Walter, Sebastian G; Schwering, Tobias; Preiss, Stefan

    2017-01-01

    Introduction: Achondroplasia is the most common form of dwarfism in humans and is orthopedically characterized by shortened extremities and an exaggerated lumbar lordosis. The surgical challenges are maintenance of axial alignment during limb lengthening as well as joint preservation and alignment restoration. Case Report: We present a 46-year-old female suffering from achondroplasia with severe pain in both knees. Severe varus deformities of both femurs and degeneration of both knee joints became apparent on clinical and radiological examination. On each femur, we performed one-staged, lateral closed-wedge osteotomy, and total knee arthroplasty (TKA). Subsequently, the patient was relieved of knee joint pain and gained a greater range of motion. Conclusion: One-staged valgization osteotomy and concomitant TKA represents a challenging, yet reasonable, surgical solution in axially severe malaligned and joint degenerated patients. PMID:28819598

  2. Description of the rates, trends and surgical burden associated with revision for prosthetic joint infection following primary and revision knee replacements in England and Wales: an analysis of the National Joint Registry for England, Wales, Northern Ireland and the Isle of Man.

    PubMed

    Lenguerrand, Erik; Whitehouse, Michael R; Beswick, Andrew D; Toms, Andrew D; Porter, Martyn L; Blom, Ashley W

    2017-07-10

    To describe the prevalence rates of revision surgery for the treatment of prosthetic joint infection (PJI) for patients undergoing knee replacement, their time trends, the cumulative incidence function of revision for PJI and estimate the burden of PJI at health service level. We analysed revision knee replacements performed due to a diagnosis of PJI and the linked index procedures recorded in the National Joint Registry from 2003 to 2014 for England and Wales. The cohort analysed consisted of 679 010 index primary knee replacements, 33 920 index revision knee replacements and 8247 revision total knee replacements performed due to a diagnosis of PJI. The prevalence rates, their time trends investigated by time from index surgery to revision for PJI, cumulative incidence functions and the burden of PJI (total procedures) were calculated. Overall linear trends were investigated with log-linear regression. The incidence of revision total knee replacement due to PJI at 2 years was 3.2/1000 following primary and 14.4/1000 following revision knee replacement, respectively. The prevalence of revision due to PJI in the 3 months following primary knee replacement has risen by 2.5-fold (95% CI 1.2 to 5.3) from 2005 to 2013 and 7.5-fold (95% CI 1.0 to 56.1) following revision knee replacement. Over 1000 procedures per year are performed as a consequence of knee PJI, an increase of 2.8 from 2005 to 2013. Overall, 75% of revisions were two-stage with an increase in use of single-stage from 7.9% in 2005 to 18.8% in 2014. Although the risk of revision due to PJI following knee replacement is low, it is rising, and coupled with the established and further predicted increased incidence of both primary and revision knee replacements, this represents an increasing and substantial treatment burden for orthopaedic service delivery in England and Wales. This has implications for future service design and the funding of individual and specialist centres. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  3. Description of the rates, trends and surgical burden associated with revision for prosthetic joint infection following primary and revision knee replacements in England and Wales: an analysis of the National Joint Registry for England, Wales, Northern Ireland and the Isle of Man

    PubMed Central

    Lenguerrand, Erik; Whitehouse, Michael R; Beswick, Andrew D; Toms, Andrew D; Porter, Martyn L; Blom, Ashley W

    2017-01-01

    Objectives To describe the prevalence rates of revision surgery for the treatment of prosthetic joint infection (PJI) for patients undergoing knee replacement, their time trends, the cumulative incidence function of revision for PJI and estimate the burden of PJI at health service level. Design We analysed revision knee replacements performed due to a diagnosis of PJI and the linked index procedures recorded in the National Joint Registry from 2003 to 2014 for England and Wales. The cohort analysed consisted of 679 010 index primary knee replacements, 33 920 index revision knee replacements and 8247 revision total knee replacements performed due to a diagnosis of PJI. The prevalence rates, their time trends investigated by time from index surgery to revision for PJI, cumulative incidence functions and the burden of PJI (total procedures) were calculated. Overall linear trends were investigated with log-linear regression. Results The incidence of revision total knee replacement due to PJI at 2 years was 3.2/1000 following primary and 14.4/1000 following revision knee replacement, respectively. The prevalence of revision due to PJI in the 3 months following primary knee replacement has risen by 2.5-fold (95% CI 1.2 to 5.3) from 2005 to 2013 and 7.5-fold (95% CI 1.0 to 56.1) following revision knee replacement. Over 1000 procedures per year are performed as a consequence of knee PJI, an increase of 2.8 from 2005 to 2013. Overall, 75% of revisions were two-stage with an increase in use of single-stage from 7.9% in 2005 to 18.8% in 2014. Conclusions Although the risk of revision due to PJI following knee replacement is low, it is rising, and coupled with the established and further predicted increased incidence of both primary and revision knee replacements, this represents an increasing and substantial treatment burden for orthopaedic service delivery in England and Wales. This has implications for future service design and the funding of individual and specialist centres. PMID:28698316

  4. Is Participation in Certain Sports Associated With Knee Osteoarthritis? A Systematic Review.

    PubMed

    Driban, Jeffrey B; Hootman, Jennifer M; Sitler, Michael R; Harris, Kyle P; Cattano, Nicole M

    2017-06-02

      Information regarding the relative risks of developing knee osteoarthritis (OA) as a result of sport participation is critical for shaping public health messages and for informing knee-OA prevention strategies. The purpose of this systematic review was to investigate the association between participation in specific sports and knee OA.   We completed a systematic literature search in September 2012 using 6 bibliographic databases (PubMed; Ovid MEDLINE; Journals@Ovid; American College of Physicians Journal Club; Cochrane Central Register of Controlled Trials, Cochrane Database of Systematic Review, Database of Abstracts of Reviews of Effects; and Ovid HealthStar), manual searches (4 journals), and reference lists (56 articles).   Studies were included if they met the following 4 criteria: (1) an aim was to investigate an association between sport participation and knee OA; (2) the outcome measure was radiographic knee OA, clinical knee OA, total knee replacement, self-reported diagnosis of knee OA, or placement on a waiting list for a total knee replacement; (3) the study design was case control or cohort; and (4) the study was written in English. Articles were excluded if the study population had an underlying condition other than knee OA.   One investigator extracted data (eg, group descriptions, knee OA prevalence, source of nonexposed controls).   The overall knee-OA prevalence in sport participants (n = 3759) was 7.7%, compared with 7.3% among nonexposed controls (referent group n = 4730, odds ratio [OR] = 1.1). Specific sports with a significantly higher prevalence of knee OA were soccer (OR = 3.5), elite-level long-distance running (OR = 3.3), competitive weight lifting (OR = 6.9), and wrestling (OR = 3.8). Elite-sport (soccer or orienteering) and nonelite-sport (soccer or American football) participants without a history of knee injury had a greater prevalence of knee OA than nonexposed participants.   Participants in soccer (elite and nonelite), elite-level long-distance running, competitive weight lifting, and wrestling had an increased prevalence of knee OA and should be targeted for risk-reduction strategies.

  5. Is Participation in Certain Sports Associated With Knee Osteoarthritis? A Systematic Review

    PubMed Central

    Hootman, Jennifer M.; Sitler, Michael R.; Harris, Kyle P.; Cattano, Nicole M.

    2017-01-01

    Objective:  Information regarding the relative risks of developing knee osteoarthritis (OA) as a result of sport participation is critical for shaping public health messages and for informing knee-OA prevention strategies. The purpose of this systematic review was to investigate the association between participation in specific sports and knee OA. Data Sources:  We completed a systematic literature search in September 2012 using 6 bibliographic databases (PubMed; Ovid MEDLINE; Journals@Ovid; American College of Physicians Journal Club; Cochrane Central Register of Controlled Trials, Cochrane Database of Systematic Review, Database of Abstracts of Reviews of Effects; and Ovid HealthStar), manual searches (4 journals), and reference lists (56 articles). Study Selection:  Studies were included if they met the following 4 criteria: (1) an aim was to investigate an association between sport participation and knee OA; (2) the outcome measure was radiographic knee OA, clinical knee OA, total knee replacement, self-reported diagnosis of knee OA, or placement on a waiting list for a total knee replacement; (3) the study design was case control or cohort; and (4) the study was written in English. Articles were excluded if the study population had an underlying condition other than knee OA. Data Extraction:  One investigator extracted data (eg, group descriptions, knee OA prevalence, source of nonexposed controls). Data Synthesis:  The overall knee-OA prevalence in sport participants (n = 3759) was 7.7%, compared with 7.3% among nonexposed controls (referent group n = 4730, odds ratio [OR] = 1.1). Specific sports with a significantly higher prevalence of knee OA were soccer (OR = 3.5), elite-level long-distance running (OR = 3.3), competitive weight lifting (OR = 6.9), and wrestling (OR = 3.8). Elite-sport (soccer or orienteering) and nonelite-sport (soccer or American football) participants without a history of knee injury had a greater prevalence of knee OA than nonexposed participants. Conclusions:  Participants in soccer (elite and nonelite), elite-level long-distance running, competitive weight lifting, and wrestling had an increased prevalence of knee OA and should be targeted for risk-reduction strategies. PMID:25574790

  6. Bilateral periprosthetic tibial stress fracture after total knee arthroplasty: A case report.

    PubMed

    Ozdemir, Guzelali; Azboy, Ibrahim; Yilmaz, Baris

    2016-01-01

    Periprosthetic fractures around the knee after total knee arthroplasty can be seen in the femur, tibia and patella. The tibial fractures are rare cases. Our case with bilateral tibial stress fracture developed after total knee arthroplasty (TKA) is the first of its kind in the literature. 75-year-old male patient with bilateral knee osteoarthritis had not benefited from conservative treatment methods previously applied. Left TKA was applied. In the second month postoperatively, periprosthetic tibial fracture was identified and osteosynthesis was implemented with locked tibia proximal plate-screw. Bone union in 12 weeks was observed in his follow-ups. After 15 months of his first operation, TKA was applied to the right knee. Postoperatively in the second month, as in the first operation, periprosthetic tibial fracture was detected. Osteosynthesis with locking plate-screw was applied and union in 12 weeks was observed in his follow-up. He was seen mobilized independently and without support in the last control of the case made in the 24th month after the second operation. The number of TKA applications is expected to increase in the future. The incidence of periprosthetic fractures should also be expected to increase in these cases. Periprosthetic tibial fractures after TKA are rarely seen. The treatment of periprosthetic fractures around the knee after TKA can be difficult. In the case of persistent pain in the upper end of the tibia after the surgery, stress fracture should be considered. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.

  7. Total knee replacement with natural rollback.

    PubMed

    Wachowski, Martin Michael; Walde, Tim Alexander; Balcarek, Peter; Schüttrumpf, Jan Philipp; Frosch, Stephan; Stauffenberg, Caspar; Frosch, Karl-Heinz; Fiedler, Christoph; Fanghänel, Jochen; Kubein-Meesenburg, Dietmar; Nägerl, Hans

    2012-03-20

    A novel class of total knee replacement (AEQUOS G1) is introduced which features a unique design of the articular surfaces. Based on the anatomy of the human knee and differing from all other prostheses, the lateral tibial "plateau" is convexly curved and the lateral femoral condyle is posteriorly shifted in relation to the medial femoral condyle. Under compressive forces the configuration of the articular surfaces of human knees constrains the relative motion of femur and tibia in flexion/extension. This constrained motion is equivalent to that of a four-bar linkage, the virtual 4 pivots of which are given by the centres of curvature of the articulating surfaces. The dimensions of the four-bar linkage were optimized to the effect that constrained motion of the total knee replacement (TKR) follows the flexional motion of the human knee in close approximation, particularly during gait. In pilot studies lateral X-ray pictures have demonstrated that AEQUOS G1 can feature the natural rollback in vivo. Rollback relieves the load of the patello-femoral joint and minimizes retropatellar pressure. This mechanism should reduce the prevalence of anterior knee pain. The articulating surfaces roll predominantly in the stance phase. Consequently sliding friction is replaced by the lesser rolling friction under load. Producing rollback should minimize material wear due to friction and maximize the lifetime of the prosthesis. To definitely confirm these theses one has to wait for the long term results. Copyright © 2011 Elsevier GmbH. All rights reserved.

  8. The Effect of Patellar Thickness on Intraoperative Knee Flexion and Patellar Tracking in Patients With Arthrofibrosis Undergoing Total Knee Arthroplasty.

    PubMed

    Kim, Abraham D; Shah, Vivek M; Scott, Richard D

    2016-05-01

    We evaluated the intraoperative effect of patellar thickness on intraoperative passive knee flexion and patellar tracking during total knee arthroplasty (TKA) in patients with preoperative arthrofibrosis and compared them to patients with normal preoperative range of motion (ROM) documented in a prior study. Routine posterior cruciate ligament-retaining TKA was performed in a total of 34 knees, 23 with normal ROM and 11 with arthrofibrosis, defined as ≤100° of passive knee flexion against gravity under anesthesia. Once clinical balance and congruent patellar tracking were established, custom trial patellar components thicker than the standard trial by 2-mm increments (2-8 mm) were sequentially placed and trialed. Passive flexion against gravity was recorded using digital photograph goniometry. Gross mechanics of patellofemoral tracking were visually assessed. On average, passive knee flexion decreased 2° for every 2-mm increment of patellar thickness (P < .0001), which was similar to patients with normal preoperative ROM. In addition, increased patellar thickness had no gross effect on patellar subluxation and tilt in patients with arthrofibrosis as well as those with normal ROM. Patellar thickness had a modest effect on intraoperative passive flexion and no effect on patellar tracking in patients with arthrofibrosis undergoing TKA. There was no marked difference in intraoperative flexion and patellar tracking between patients with arthrofibrosis and patients with normal preoperative ROM. Copyright © 2016 Elsevier Inc. All rights reserved.

  9. Influence of Different Patellofemoral Design Variations Based on Genesis II Total Knee Endoprosthesis on Patellofemoral Pressure and Kinematics

    PubMed Central

    Lange, Barbara; Herzog, Yvonne; Schnauffer, Peter; Leichtle, Carmen I.; Wülker, Nikolaus

    2017-01-01

    In total knee arthroplasty (TKA), patellofemoral groove design varies greatly and likely has a distinct influence on patellofemoral biomechanics. To analyse the selective influence, five patellofemoral design variations were developed based on Genesis II total knee endoprosthesis (original design, being completely flat, being laterally elevated, being medially elevated, and both sides elevated) and made from polyamide using rapid prototyping. Muscle-loaded knee flexion was simulated on 10 human knee specimens using a custom-made knee simulator, measuring the patellofemoral pressure distribution and tibiofemoral and patellofemoral kinematics. The measurements were carried out in the native knee as well as after TKA with the 5 design prototypes. The overall influence of the different designs on the patellofemoral kinematics was small, but we found detectable effects for mediolateral tilt (p < 0.05 for 35°–80° flexion) and translation of the patella (p < 0.045 for 20°–65° and 75°–90°), especially for the completely flat design. Considering patellofemoral pressures, major interindividual differences were seen between the designs, which, on average, largely cancelled each other out. These results suggest that the elevation of the lateral margin of the patellofemoral groove is essential for providing mediolateral guidance, but smooth contouring as with original Genesis II design seems to be sufficient. The pronounced interindividual differences identify a need for more patellofemoral design options in TKA. PMID:28255225

  10. Arthroscopic lysis of adhesions improves knee range of motion after fixation of intra-articular fractures about the knee.

    PubMed

    Gittings, Daniel; Hesketh, Patrick; Dattilo, Jonathan; Zgonis, Miltiadis; Kelly, John; Mehta, Samir

    2016-12-01

    Post-traumatic stiffness after open reduction and internal fixation of fractures about the knee can have dramatic effects on function. Traditionally, open quadricepsplasty has been the treatment of choice, but is associated with significant morbidity. The purpose of this study is to examine the immediate and sustainable range of motion (ROM) changes after surgical arthroscopic lysis of knee adhesions (SALKA) for post-traumatic knee stiffness after open reduction internal fixation (ORIF). We retrospectively reviewed a consecutive series of patients at a single institution who underwent SALKA for knee stiffness after intra-articular fractures about the knee treated with ORIF from 2009 to 2015. Pre-operative and immediate post-operative total ROM was assessed while patients were sedated during the SALKA procedure. Total ROM was assessed in the office pre-operatively and compared to the latest post-operative follow-up visit. Immediate post-operative ROM was also compared to the latest post-operative follow-up visit. Two-tailed paired Student's t test was calculated for analysis. Of the 14 patients included in the study, 10 (71 %) had tibial plateau ORIF, 3 (21 %) had patella ORIF, and 1 (8 %) had intra-articular distal femur ORIF. The mean time between ORIF and SALKA was 244 days. The mean follow-up time after SALKA was 135 days. Under sedation during SALKA, the mean total ROM increased from 72° to 127° immediately post-operatively (p < 0.01). The mean pre-operative in-office total ROM was 73° and increased to 104° at the latest follow-up visit (p < 0.01). The mean immediate post-operative ROM was 127° and decreased to 104° at the latest follow-up visit (p = 0.01). Lysis of adhesions utilizing SALKA after ORIF about the knee improves knee ROM immediately post-operatively and in the short-term follow-up. However, there is a decrease in the gains in the range of motion over time. Patients should be counseled as such. Lysis of adhesions utilizing arthroscopic techniques may provide a favorable alternative to open quadricepsplasty.

  11. The effect of tourniquet and knee position during wound closure after total knee arthroplasty on early recovery of range of motion: a prospective, randomized study.

    PubMed

    Şükür, Erhan; Öztürkmen, Yusuf; Akman, Yunus Emre; Senel, Ahmet; Azboy, İbrahim

    2016-12-01

    There is no consensus on the position of the knee joint while performing wound closure after total knee arthroplasty (TKA). Further, there are no studies focusing on the association between early functional outcomes and different wound closure strategies. Therefore, we investigated the effects of tourniquet and knee position during wound closure on early recovery of range of motion (ROM) after primary TKA. To our knowledge, this is the first study to evaluate the influence of both tourniquet and knee position during wound closure in primary TKA. One hundred-twenty eligible patients were consecutively enrolled in this study and randomly divided into four groups according to wound closure strategy. Wound closure was either performed with the knee in flexion at 90° or in full extension, with the combination of an inflated or deflated tourniquet. Visual analogue score (VAS), knee ROM, ROM recovery, knee society score (KSS), and wound complications were evaluated in the early postoperative period. After the first postoperative week, ROM recovery in the group with knee in extension and inflated tourniquet was significantly lesser than the two groups with deflated tourniquets. Between the first and fourth postoperative weeks, ROM recovery in the group with knee inflection and deflated tourniquet was significantly higher than the two groups with knee in extension. After the first postoperative week, the visual analog score (VAS) for pain in the group with knee inflection and deflated tourniquet was significantly lesser than the two groups with inflated tourniquets. The differences in the outcomes between the four groups were not significant after the fourth postoperative week. The incidence of wound complications and KSS were not significantly different between the four groups. Following TKA, wound closure with the knee in flexion and after deflating the tourniquet significantly decreased postoperative pain and promoted the recovery of ROM in the early postoperative period.

  12. Knee osteoarthritis and role for surgical intervention: lessons learned from randomized clinical trials and population-based cohorts.

    PubMed

    Buchbinder, Rachelle; Richards, Bethan; Harris, Ian

    2014-03-01

    Over the last decade, there has been increased recognition of the importance of high-quality randomized controlled trials in determining the role of surgery for knee osteoarthritis. This review highlights key findings from the best available studies, and considers whether or not this knowledge has resulted in better evidence-based care. Use of arthroscopy to treat knee osteoarthritis has not declined despite strong evidence-based recommendations that do not sanction its use. A large randomized controlled trial has demonstrated that arthroscopic partial meniscectomy followed by a standardized physical therapy program results in similar improvements in pain and function at 6 and 12 months in comparison to physical therapy alone in patients with knee osteoarthritis and a symptomatic meniscal tear, confirming the findings of two previous trials. Two recent randomized controlled trials have demonstrated that decision aids help people to reach better-informed decisions about total knee arthroplasty. A majority of studies have indicated that for people with obesity the positive results of total knee arthroplasty may be compromised by postoperative complications, particularly infection. More efforts are needed to overcome significant evidence-practice gaps in the surgical management of knee osteoarthritis, particularly arthroscopy. Decision aids are a promising tool.

  13. Effects of balance and proprioceptive training on total hip and knee replacement rehabilitation: A systematic review and meta-analysis.

    PubMed

    Domínguez-Navarro, Fernando; Igual-Camacho, Celedonia; Silvestre-Muñoz, Antonio; Roig-Casasús, Sergio; Blasco, José María

    2018-05-01

    Balance and proprioceptive deficits are frequently persistent after total joint replacement, limiting functionality and involving altered movement patterns and difficulties in walking and maintaining postural control among patients. The goal of this systematic review was to evaluate the short- and mid-term effects of proprioceptive and balance training for patients undergoing total knee and hip replacement. This is a systematic review of literature. MEDLINE, Embase, Cochrane Library, PEDro, and Scopus were the databases searched. The review included randomized clinical trials in which the experimental groups underwent a training aimed at improving balance and proprioception, in addition to conventional care. The studies had to assess at least one of the following outcomes: self-reported functionality or balance (primary outcomes), knee function, pain, falls, or quality of life. Eight trials were included, involving 567 participants. The quantitative synthesis found a moderate to high significant effect of balance and proprioceptive trainings on self-reported functionality and balance after total knee replacement. The effects were maintained at mid-term in terms of balance alone. Conversely, preoperative training did not enhance outcomes after total hip arthroplasty. The synthesis showed that, in clinical terms, balance trainings are a convenient complement to conventional physiotherapy care to produce an impact on balance and functionality after knee replacement. If outcomes such as improvement in pain, knee range of movement, or patient quality of life are to be promoted, it would be advisable to explore alternative proposals specifically targeting these goals. Further research is needed to confirm or discard the current evidence ultimately, predominantly in terms of the effects on the hips and those yielded by preoperative interventions. Copyright © 2018 Elsevier B.V. All rights reserved.

  14. Ten- to 15-year results of the Oxford Phase III mobile unicompartmental knee arthroplasty: a prospective study from a non-designer group.

    PubMed

    Lisowski, L A; Meijer, L I; Bekerom, M P J van den; Pilot, P; Lisowski, A E

    2016-10-01

    The interest in unicompartmental knee arthroplasty (UKA) for medial osteoarthritis has increased rapidly but the long-term follow-up of the Oxford UKAs has yet to be analysed in non-designer centres. We have examined our ten- to 15-year clinical and radiological follow-up data for the Oxford Phase III UKAs. Between January 1999 and January 2005 a total of 138 consecutive Oxford Phase III arthroplasties were performed by a single surgeon in 129 patients for medial compartment osteoarthritis (71 right and 67 left knees, mean age 72.0 years (47 to 91), mean body mass index 28.2 (20.7 to 52.2)). Both clinical data and radiographs were prospectively recorded and obtained at intervals. Of the 129 patients, 32 patients (32 knees) died, ten patients (12 knees) were not able to take part in the final clinical and radiological assessment due to physical and mental conditions, but via telephone interview it was confirmed that none of these ten patients (12 knees) had a revision of the knee arthroplasty. One patient (two knees) was lost to follow-up. The mean follow-up was 11.7 years (10 to 15). A total of 11 knees (8%) were revised. The survival at 15 years with revision for any reason as the endpoint was 90.6% (95% confidence interval (CI) 85.2 to 96.0) and revision related to the prosthesis was 99.3% (95% CI 97.9 to 100). The mean total Knee Society Score was 47 (0 to 80) pre-operatively and 81 (30 to 100) at latest follow-up. The mean Oxford Knee Score was 19 (12 to 40) pre-operatively and 42 (28 to 55) at final follow-up. Radiolucency beneath the tibial component occurred in 22 of 81 prostheses (27.2%) without evidence of loosening. This study supports the use of UKA in medial compartment osteoarthritis with excellent long-term functional and radiological outcomes with an excellent 15-year survival rate. Cite this article: Bone Joint J 2016;98-B(10 Suppl B):41-7. ©2016 Lisowski et al.

  15. Low-grade infection after a total knee arthroplasty caused by Actinomyces naeslundii.

    PubMed

    Hedke, J; Skripitz, R; Ellenrieder, M; Frickmann, H; Köller, T; Podbielski, A; Mittelmeier, W

    2012-08-01

    Here, we present a case of an 85-year-old woman with a low-grade-infection caused by Actinomyces naeslundii after total-knee arthroplasty (TKA) followed by septic loosening. Actinomyces naeslundii was cultured from a tissue sample from the knee joint capsule/synovial tissue obtained after the initial TKA. A review of the literature revealed two cases of periprosthetic infection and another three cases of arthritis due to Actinomyces naeslundii. So far, no standard treatment for periprosthetic infections caused by Actinomyces species has been established.

  16. Hip and knee replacement in osteogenesis imperfecta.

    PubMed

    Papagelopoulos, P J; Morrey, B F

    1993-04-01

    Five total hip and three total knee arthroplasties were performed, from 1969 to 1990, in six patients who had osteogenesis imperfecta. The patients who had a hip arthroplasty were followed for a mean of seven years, and those who had a knee arthroplasty, for a mean of ten years. Postoperatively, all had relief of pain and were able to walk; one patient used a walker and two used a cane. The only postoperative complication was an intrapelvic protrusion of the acetabular component six years after a bipolar hip replacement.

  17. Joint Stability in Total Knee Arthroplasty: What Is the Target for a Stable Knee?

    PubMed

    Wright, Timothy M

    2017-02-01

    Instability remains a common cause of failure in total knee arthroplasty. Although approaches for surgical treatment of instability exist, the target for initial stability remains elusive, increasing the likelihood that failures will persist because adequate stability is not restored when performing the primary arthroplasty. Although the mechanisms that stabilize the knee joint-contact between the articular surfaces, ligamentous constraints, and muscle forces-are well-defined, their relative importance and the interplay among them throughout functions of daily living are poorly understood. The problem is exacerbated by the complex multiplanar motions that occur across the joint and the large variations in these motions across the population, suggesting that stability targets may need to be patient-specific.

  18. Reply.

    PubMed

    Aggarwal, Aakanksha

    2018-05-19

    We totally agree with the statement of the authors of the letter to the editor that "the incidence of CRPS knee following trauma or otherwise is not well appreciated". We would like to refer to our earlier published paper in which we concluded that the scientific literature does report cases of CRPS type I of only the knee(s). Our recommendation was to consider CRPS confined to the knee as a medical entity and therefore to include CRPS of only the knee(s) in future research on the etiological mechanisms of and optimal treatment for CRPS [1]. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  19. Timing of rehabilitation on length of stay and cost in patients with hip or knee joint arthroplasty: A systematic review with meta-analysis

    PubMed Central

    Masaracchio, Michael; Hanney, William J.; Liu, Xinliang; Kolber, Morey; Kirker, Kaitlin

    2017-01-01

    Objective To investigate the role of early initiation of rehabilitation on length of stay (LOS) and cost following total hip arthroplasty, total knee arthroplasty, or unicompartmental knee arthroplasty. Data sources Electronic databases PubMed, CINAHL, Pedro, Embase, AMED, and the Cochrane Library were searched in July 2016. Five additional trials were identified through reference list scanning. Study selection Eligible studies were published in English language peer-reviewed journals; included participants that had undergone total hip arthroplasty, total knee arthroplasty, or unicompartmental knee arthroplasty reported clearly defined timing of rehabilitation onset for at least two groups; and reported at least one measure of LOS or cost. Inclusion criteria were applied by 2 independent authors, with disagreements being determined by a third author. Searching identified 1,029 potential articles, of which 17 studies with 26,614 participants met the inclusion criteria. Data extraction Data was extracted independently by 2 authors, with disagreements being determined by a third author. Methodological quality of each study was evaluated independently by 2 authors using the Downs and Black checklist. Pooled analyses were analyzed using a random-effects model with inverse variance methods to calculate standardized mean differences (SMD) and 95% confidence intervals for LOS. Data synthesis When compared with standard care, early initiation of physical therapy demonstrated a decrease in length of stay for the 4 randomized clinical trials (SMD = -1.90; 95% CI -2.76 to -1.05; I2 = 93%) and for the quasi-experimental and 5 prospective studies (SMD = -1.47; 95% CI -1.85 to -1.10; I2 = 88%). Conclusion Early initiation of rehabilitation following total hip arthroplasty, total knee arthroplasty, or unicompartmental knee arthroplasty is associated with a shorter LOS, a lower overall cost, with no evidence of an increased number of adverse reactions. Additional high quality studies with standardized methodology are needed to further examine the impact of early initiation of physical therapy among patients with joint replacement procedures. PMID:28575058

  20. Suture anchor repair of quadriceps tendon rupture after total knee arthroplasty.

    PubMed

    Kim, Tae Won B; Kamath, Atul F; Israelite, Craig L

    2011-08-01

    Disruption of the extensor mechanism after total knee arthroplasty (TKA) is a devastating complication, usually requiring surgical repair. Although suture anchor fixation is well described for repair of the ruptured native knee quadriceps tendon, no study has discussed the use of suture anchors in quadriceps repair after TKA. We present an illustrative case of successful suture anchor fixation of the quadriceps mechanism after TKA. The procedure has been performed in a total of 3 patients. A surgical technique and brief review of the literature follows. Suture anchor fixation of the quadriceps tendon is a viable option in the setting of rupture after TKA. Copyright © 2011 Elsevier Inc. All rights reserved.

  1. Wear simulation of total knee prostheses using load and kinematics waveforms from stair climbing.

    PubMed

    Abdel-Jaber, Sami; Belvedere, Claudio; Leardini, Alberto; Affatato, Saverio

    2015-11-05

    Knee wear simulators are meant to perform load cycles on knee implants under physiological conditions, matching exactly, if possible, those experienced at the replaced joint during daily living activities. Unfortunately, only conditions of low demanding level walking, specified in ISO-14243, are used conventionally during such tests. A recent study has provided a consistent knee kinematic and load data-set measured during stair climbing in patients implanted with a specific modern total knee prosthesis design. In the present study, wear simulation tests were performed for the first time using this data-set on the same prosthesis design. It was hypothesised that more demanding tasks would result in wear rates that differ from those observed in retrievals. Four prostheses for total knee arthroplasty were tested using a displacement-controlled knee wear simulator for two million cycles at 1.1 Hz, under kinematics and load conditions typical of stair climbing. After simulation, the corresponding damage scars on the bearings were qualified and compared with equivalent explanted prostheses. An average mass loss of 20.2±1.5 mg was found. Scanning digital microscopy revealed similar features, though the explant had a greater variety of damage modes, including a high prevalence of adhesive wear damage and burnishing in the overall articulating surface. This study confirmed that the results from wear simulation machines are strongly affected by kinematics and loads applied during simulations. Based on the present results for the full understanding of the current clinical failure of knee implants, a more comprehensive series of conditions are necessary for equivalent simulations in vitro. Copyright © 2015 Elsevier Ltd. All rights reserved.

  2. Retention of the posterior cruciate ligament versus the posterior stabilized design in total knee arthroplasty: a prospective randomized controlled clinical trial

    PubMed Central

    van den Boom, Lennard GH; Brouwer, Reinoud W; van den Akker-Scheek, Inge; Bulstra, Sjoerd K; van Raaij, Jos JAM

    2009-01-01

    Background Prosthetic design for the use in primary total knee arthroplasty has evolved into designs that preserve the posterior cruciate ligament (PCL) and those in which the ligament is routinely sacrificed (posterior stabilized). In patients with a functional PCL the decision which design is chosen depends largely on the favour and training of the surgeon. The objective of this study is to determine whether the patient's perceived outcome and speed of recovery differs between a posterior cruciate retaining total knee arthroplasty and a posterior stabilized total knee arthroplasty. Methods/Design A randomized controlled trial will be conducted. Patients who are admitted for primary unilateral TKA due to primary osteoarthrosis are included when the following inclusion criteria are met: non-fixed fixed varus or valgus deformity less than 10 degrees, age between 55 and 85 years, body mass index less than 35 kg/m2 and ASA score (American Society of Anaesthesiologists) I or II. Patients are randomized in 2 groups. Patients in the posterior cruciate retaining group will receive a prosthesis with a posterior cut-out for the posterior cruciate ligament and relatively flat topography. In patients allocated to the posterior stabilized group, in which the posterior cruciate ligament is excised, the design may substitute for this function by an intercondylar tibial prominence that articulates with the femur in flexion. Measurements will take place preoperatively and 6 weeks, 3 months, 6 months and 1 year postoperatively. At all measurement points patient's perceived outcome will be assessed using the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC). Secondary outcome measures are quality of life (SF-36) and physician reported functional status and range of motion as determined with the Knee Society Clinical Rating System (KSS). Discussion In the current practice both posterior cruciate retaining and posterior stabilized designs for total knee arthroplasty are being used. To date no studies have been performed determining whether there is a difference in patient's perceived outcome between the two designs. Additionally, there is a lack of studies determining the speed of recovery in both designs as most studies only determine the final outcome. This randomised controlled study has been designed to determine whether the patient's perceived outcome and speed of recovery differs between a posterior cruciate retaining total knee arthroplasty and a posterior stabilized total knee arthroplasty. Trial Registration The trial is registered in the Netherlands Trial Registry (NTR1673). PMID:19793397

  3. Total knee arthroplasty following prior distal femoral fracture.

    PubMed

    Papadopoulos, Elias C; Parvizi, Javad; Lai, Choon H; Lewallen, David G

    2002-12-01

    Femoral fracture may predispose the knee to the development of post-traumatic arthritis by either a direct intra-articular injury or residual limb malalignment. Malunion, intra-articular osseous defects, limb malalignment, retained internal fixation devices, and compromised surrounding soft tissues may in turn affect the outcome of total knee arthroplasty (TKA) in these patients. The aim of our study was to evaluate the result of TKA in patients with previous distal femoral fracture. The results of 48 cemented condylar total knee arthroplasties, performed between 1980 to 1998, in 47 patients with a previous distal femoral fracture were reviewed. There were 37 females and 10 males with an average age of 65 years (range, 19-84 years). Follow-up averaged 6.2 years (range, 2-16 years). No patients were lost to follow-up. At the time of arthroplasty a femoral fracture non-union was present in three knees, all of which were treated with a long stem cemented femoral component and bone grafting. Malunion, defined as angulation greater than 10 degrees in the coronal plain or greater than 15 degrees in the sagittal plain, was present in 21 knees. Of these, six underwent distal femoral osteotomy during TKA. In the remaining 15 patients, with a malunion, the deformity was addressed by alterations in the orientation and location of bone resection. Other procedures were commonly needed at the time of arthroplasty and included: lateral retinacular release (22 knees), extensor mechanism realignment (eight knees), and collateral ligament reconstruction (two knees). The mean pre-operative Knee Society Scores were 40 (range, 0-80) for pain and 48 (range, 0-100) for function and improved significantly to a mean of 84 (range, 37-99) and 66 (range, 0-100) points, respectively, at the latest follow-up (P<0.001). The knee arc of motion improved from a pre-operative mean of 83-99 degrees at the latest follow-up (P<0.004). Post-operative manipulation under anesthesia for poor motion was carried out in four knees. Two knees had aseptic loosening that required subsequent revisions. Three knees developed deep infection which was treated with debridement and retention of components in one knee, arthrodesis in another, and eventual amputation in one knee. Significant improvement in function and relief of pain is seen in the vast majority of patients with previous distal femoral fractures undergoing subsequent TKA. However, these patients are at increased risk for restricted motion and perioperative complications following TKA. Special efforts to preserve the vascularity of the skin and subcutaneous tissues, restore limb alignment, ensure correct component positioning, and achieve soft tissue balance may help minimize the problems identified in this study.

  4. The effect of technique change on knee loads during sidestep cutting.

    PubMed

    Dempsey, Alasdair R; Lloyd, David G; Elliott, Bruce C; Steele, Julie R; Munro, Bridget J; Russo, Kylie A

    2007-10-01

    To identify the effect of modifying sidestep cutting technique on knee loads and predict what impact such change would have on the risk of noncontact anterior cruciate ligament injury. A force platform and motion-analysis system were used to record ground-reaction forces and track the trajectories of markers on 15 healthy males performing sidestep cutting tasks using their normal technique and nine different imposed techniques. A kinematic and inverse dynamic model was used to calculate the three-dimensional knee postures and moments. The imposed techniques of foot wide and torso leaning in the opposite direction to the cut resulted in increased peak valgus moments experienced in weight acceptance. Higher peak internal rotation moments were found for the foot wide and torso rotation in the opposite direction to the cut techniques. The foot rotated in technique resulted in lower mean flexion/extension moments, whereas the foot wide condition resulted in higher mean flexion/extension moments. The flexed knee, torso rotated in the opposite direction to the cut and torso leaning in the same direction as the cut techniques had significantly more knee flexion at heel strike. Sidestep cutting technique had a significant effect on loads experienced at the knee. The techniques that produced higher valgus and internal rotation moments at the knee, such as foot wide, torso leaning in the opposite direction to the cut and torso rotating in the opposite direction to the cut, may place an athlete at higher risk of injury because these knee loads have been shown to increase the strain on the anterior cruciate ligament. Training athletes to avoid such body positions may result in a reduced risk of noncontact anterior cruciate ligament injures.

  5. A systematic review of the effects of platelet rich plasma on outcomes for patients with knee osteoarthritis and following total knee arthroplasty.

    PubMed

    Muchedzi, Tendai Aswad; Roberts, Simon B

    2017-09-21

    Platelet rich plasma (PRP) has been suggested to be effective in the management of knee osteoarthritis. Review of current literature reveals conflicting evidence regarding the benefits of PRP in treating knee OA. Preclinical evidence supports the use of PRP injections to promote a favorable environment for joint tissue healing, targeting not only cartilage but also synovial and meniscal tissues which has a positive effect on delaying the progression of OA. Growth factors found in platelet granules are postulated to influence outcomes in knee OA and after total knee arthroplasty (TKA). A systematic review of studies investigating the use of PRP in knee osteoarthritis and following TKA, was performed by searching the following databases for randomised clinical trials and pseudo-randomised clinical and comparative trials comparing the use of PRP to treat knee osteoarthritis and following TKA: MedLine, EMBASE, Science Direct, PubMed, and the Cochrane Library. The primary outcomes were patient reported measures including pain (visual analog scale (VAS)), quality of life scores, and knee function. A total of 2328 participants were analyzed across 17 included studies and pooled results showed a statistically significant reduction in pain in favor of PRP following TKA but not in non-surgical management of knee OA (P < 0.0001 and 0.13 respectively). No clinical benefit of PRP was found on quality of life and knee function (P = 0.07 and 0.05) following TKA, although a statistical improvement in knee function was demonstrated in patients with knee OA after PRP injection (P < 0.0001). There was no statistically significant clinical benefit of PRP on secondary outcomes including wound scores and length of hospital stay (p = 0.33 and 0.31, respectively). There was no statistically significant difference in respect to blood loss and overall symptoms in favor of PRP compared to control group following TKA (p = 0.37). This systematic review demonstrated no long-term statistically significant improvement in patient validated outcomes and secondary outcomes both in patients with knee OA or following TKA for OA. However PRP has been shown to have short to medium-term benefits in pain control after TKA and activities of daily living in patients with OA. Copyright © 2017 Royal College of Surgeons of Edinburgh (Scottish charity number SC005317) and Royal College of Surgeons in Ireland. Published by Elsevier Ltd. All rights reserved.

  6. A comparison of regional and general anaesthesia for total replacement of the hip or knee: a meta-analysis.

    PubMed

    Hu, S; Zhang, Z-Y; Hua, Y-Q; Li, J; Cai, Z-D

    2009-07-01

    We performed a meta-analysis to evaluate the relative efficacy of regional and general anaesthesia in patients undergoing total hip or knee replacement. A comprehensive search for relevant studies was performed in PubMed (1966 to April 2008), EMBASE (1969 to April 2008) and the Cochrane Library. Only randomised studies comparing regional and general anaesthesia for total hip or knee replacement were included. We identified 21 independent, randomised clinical trials. A random-effects model was used to calculate all effect sizes. Pooled results from these trials showed that regional anaesthesia reduces the operating time (odds ratio (OR) -0.19; 95% confidence interval (CI) -0.33 to -0.05), the need for transfusion (OR 0.45; 95% CI 0.22 to 0.94) and the incidence of thromboembolic disease (deep-vein thrombosis OR 0.45, 95% CI 0.24 to 0.84; pulmonary embolism OR 0.46, 95% CI 0.29 to 0.80). Regional anaesthesia therefore seems to improve the outcome of patients undergoing total hip or knee replacement.

  7. Thromboembolic diseases and the use of vena cava filters.

    PubMed

    De Silva, Samanthi

    2017-04-01

    Mr GW is a 77-year-old gentleman who is hoping to have a total knee replacement of his left knee. He underwent a knee replacement on the right in 2011 under spinal anaesthetic, where his postoperative period was complicated by a saddle pulmonary embolus (PE). Copyright the Association for Perioperative Practice.

  8. Side-to-side asymmetries in landing mechanics from a drop vertical jump test are not related to asymmetries in knee joint laxity following anterior cruciate ligament reconstruction.

    PubMed

    Meyer, Christophe A G; Gette, Paul; Mouton, Caroline; Seil, Romain; Theisen, Daniel

    2018-02-01

    Asymmetries in knee joint biomechanics and increased knee joint laxity in patients following anterior cruciate ligament reconstruction (ACLR) are considered risk factors for re-tear or early onset of osteoarthritis. Nevertheless, the relationship between these factors has not been established. The aim of the study was to compare knee mechanics during landing from a bilateral drop vertical jump in patients following ACLR and control participants and to study the relationship between side-to-side asymmetries in landing mechanics and knee joint laxity. Seventeen patients following ACLR were evaluated and compared to 28 healthy controls. Knee sagittal and frontal plane kinematics and kinetics were evaluated using three-dimensional motion capture (200 Hz) and two synchronized force platforms (1000 Hz). Static anterior and internal rotation knee laxities were measured for both groups and legs using dedicated arthrometers. Group and leg differences were investigated using a mixed model analysis of variance. The relationship between side-to-side differences in sagittal knee power/energy absorption and knee joint laxities was evaluated using univariate linear regression. A significant group-by-leg interaction (p = 0.010) was found for knee sagittal plane energy absorption, with patients having 25% lower values in their involved compared to their non-involved leg (1.22 ± 0.39 vs. 1.62 ± 0.40 J kg -1 ). Furthermore, knee sagittal plane energy absorption was 18% lower at their involved leg compared to controls (p = 0.018). Concomitantly, patients demonstrated a 27% higher anterior laxity of the involved knee compared to the non-involved knee, with an average side-to-side difference of 1.2 mm (p < 0.001). Laxity of the involved knee was also 30% higher than that of controls (p < 0.001) (leg-by-group interaction: p = 0.002). No relationship was found between sagittal plane energy absorption and knee laxity. Nine months following surgery, ACLR patients were shown to employ a knee unloading strategy of their involved leg during bilateral landing. However, this strategy was unrelated to their increased anterior knee laxity. Side-to-side asymmetries during simple bilateral landing tasks may put ACLR patients at increased risk of second ACL injury or early-onset osteoarthritis development. Detecting and correcting asymmetric landing strategies is highly relevant in the framework of personalized rehabilitation, which calls for complex biomechanical analyses to be applied in clinical routine. III.

  9. Efficacy and safety of topical tranexamic acid in knee arthroplasty.

    PubMed

    López-Hualda, Álvaro; Dauder-Gallego, Cristina; Ferreño-Márquez, David; Martínez-Martín, Javier

    2018-02-26

    Tranexamic acid (TXA) is commonly used to control postoperative blood loss in total knee arthroplasty. In order to avoid adverse effects associated with intravenous administration, topical use has been proposed as an alternative. Our aim was to evaluate the efficacy and safety of topical TXA in total knee arthroplasty. A total of 90 patients scheduled for unilateral total knee arthroplasty were included in a prospective randomised study. All surgeries were performed under spinal anaesthesia, tourniquet and the same postoperative protocol. Patients were allocated to one of the 3 groups according to the application of TXA: group A (n=30) 1g of topical TXA; group B (n=30) 1g of TXA intravenous and in group C or the control group (n=30) no drug was administrated. Parameters related to blood loss and drain outputs were compared between the 3 groups. The results revealed that post-operative decrease in haemoglobin level was significantly lower in group A (1.95g/dL) than group B (2.25g/dL) and group C (2.96g/dL), P<.01. Total postoperative blood loss was lower in group A (195mL) than group B (466mL) and group C (718mL), P<.01. There was no significant difference in complications and allogenic blood transfusion rate between the 3 groups. According to the results, topical application of 1g TXA significantly reduced blood loss in patients undergoing total knee arthroplasty more than intravenous or no administration of TXA. Copyright © 2018 Elsevier España, S.L.U. All rights reserved.

  10. Patient outcomes using Wii-enhanced rehabilitation after total knee replacement - the TKR-POWER study.

    PubMed

    Negus, J J; Cawthorne, D P; Chen, J S; Scholes, C J; Parker, D A; March, L M

    2015-01-01

    Home-based rehabilitation following total knee replacement surgery can be as effective as clinic-based or in-patient rehabilitation. The use of the Nintendo Wii has been postulated as a novel rehabilitation tool that adds an additional focus on balance and proprioception into the recovery protocol. The aim of the proposed clinical trial is to investigate the effectiveness of this novel rehabilitation tool, used at home for three months after total knee replacement surgery and to assess any lasting improvements in functional outcome at one year. This will be a randomised controlled trial of 128 patients undergoing primary total knee replacement. The participants will be recruited preoperatively from three surgeons at a single centre. There will be no change to the usual care provided until 6 weeks after the operation. Then participants will be randomised to either the Wii-Fit group or usual rehabilitative care group. Outcomes will be assessed preoperatively, a 6-week post surgery baseline and then at 18 weeks, 6 months and 1 year. The primary outcome is the change in self-reported WOMAC total score from week 6 to 18 weeks. Secondary outcomes include objective measures of strength, function and satisfaction scores. The results of this clinical trial will be directly relevant for implementation into clinical practice. If beneficial, this affordable technology could be used by many patients to rehabilitate at home. Not only could it optimize the outcomes from their total knee replacement surgery but decrease the need for clinic-based or outpatient therapy for the majority. (ACTRN12611000291987). Copyright © 2014 Elsevier Inc. All rights reserved.

  11. Clinical results of Hi-tech Knee II total knee arthroplasty in patients with rheumatoid athritis: 5- to 12-year follow-up.

    PubMed

    Yamanaka, Hajime; Goto, Ken-ichiro; Suzuki, Munetaka

    2012-02-22

    Total knee arthroplasty (TKA) is a common form of treatment to relieve pain and improve function in cases of rheumatoid arthritis (RA). Good clinical outcomes have been reported with a variety of TKA prostheses. The cementless Hi-Tech Knee II cruciate-retaining (CR)-type prosthesis, which has 6 fins at the anterior of the femoral component, posterior cruciate ligament (PCL) retention, flat-on-flat surface component geometry, all-polyethylene patella, strong initial fixation by the center screw of the tibial base plate, 10 layers of titanium alloy fiber mesh, and direct compression molded ultra high molecular weight polyethylene (UHMWPE), is appropriate for TKA in the Japanese knee.The present study was performed to evaluate the clinical results of primary TKA in RA using the cementless Hi-Tech Knee II CR-type prosthesis. We performed 32 consecutive primary TKAs using cementless Hi-Tech Knee II CR-type prosthesis in 31 RA patients. The average follow-up period was 8 years 3 months. Clinical evaluations were performed according to the American Knee Society (KS) system, knee score, function score, radiographic evaluation, and complications. The mean postoperative maximum flexion angle was 115.6°, and the KS knee score and function score improved to 88 and 70 after surgery, respectively. Complications, such as infection, occurred in 1 patient and revision surgery was performed. There were no cases of loosening in this cohort, and prosthesis survival rate was 96.9% at 12 years postoperatively. These results suggest that TKA using the cementless Hi-Tech Knee II CR-type prosthesis is a very effective form of treatment in RA patients at 5 to 12 years postoperatively. Further long-term follow-up studies are required to determine the ultimate utility of this type of prosthesis.

  12. Influence of Medial Collateral Ligament Release for Internal Rotation of Tibia in Posterior-Stabilized Total Knee Arthroplasty: A Cadaveric Study.

    PubMed

    Wada, Keizo; Hamada, Daisuke; Tamaki, Shunsuke; Higashino, Kosaku; Fukui, Yoshihiro; Sairyo, Koichi

    2017-01-01

    Previous studies suggested that changes in kinematics in total knee arthroplasty (TKA) affected satisfaction level. The aim of this cadaveric study was to evaluate the effect of medial collateral ligament (MCL) release by multiple needle puncture on knee rotational kinematics in posterior-stabilized TKA. Six fresh, frozen cadaveric knees were included in this study. All TKA procedures were performed with an image-free navigation system using a 10-mm polyethylene insert. Tibial internal rotation was assessed to evaluate intraoperative knee kinematics. Multiple needle puncturing was performed 5, 10, and 15 times for the hard portion of the MCL at 90° knee flexion. Kinematic analysis was performed after every 5 punctures. After performing 15 punctures, a 14-mm polyethylene insert was inserted, and kinematic analysis was performed. The tibial internal rotation angle at maximum knee flexion without multiple needle puncturing was significantly larger (9.42°) than that after 15 punctures (3°). Negative correlation (Pearson r = -0.715, P < .001) between tibial internal rotation angle at maximum knee flexion and frequency of puncture was observed. The tibial internal rotation angle with a 14-mm insert was significantly larger (7.25°) compared with the angle after 15 punctures. Tibial internal rotation during knee flexion was reduced by extensive MCL release using multiple needle puncturing and was recovered by increasing of medial tightness. From the point of view of knee kinematics, medial tightness should be allowed to maintain the internal rotation angle of the tibia during knee flexion which might lead to patient satisfaction. Copyright © 2016 Elsevier Inc. All rights reserved.

  13. Effects of the Length of Stay on the Cost of Total Knee and Total Hip Arthroplasty from 2002 to 2013.

    PubMed

    Molloy, Ilda B; Martin, Brook I; Moschetti, Wayne E; Jevsevar, David S

    2017-03-01

    Utilization of total knee and hip arthroplasty has greatly increased in the past decade in the United States; these are among the most expensive procedures in patients with Medicare. Advances in surgical techniques, anesthesia, and care pathways decrease hospital length of stay. We examined how trends in hospital cost were altered by decreases in length of stay. Procedure, demographic, and economic data were collected on 6.4 million admissions for total knee arthroplasty and 2.8 million admissions for total hip arthroplasty from 2002 to 2013 using the National (Nationwide) Inpatient Sample, a component of the Healthcare Cost and Utilization Project. Trends in mean hospital costs and their association with length of stay were estimated using inflation-adjusted, survey-weighted generalized linear regression models, controlling for patient demographic characteristics and comorbidity. From 2002 to 2013, the length of stay decreased from a mean time of 4.06 to 2.97 days for total knee arthroplasty and from 4.06 to 2.75 days for total hip arthroplasty. During the same time period, the mean hospital cost for total knee arthroplasty increased from $14,988 (95% confidence interval [CI], $14,927 to $15,049) in 2002 to $22,837 (95% CI, $22,765 to $22,910) in 2013 (an overall increase of $7,849 or 52.4%). The mean hospital cost for total hip arthroplasty increased from $15,792 (95% CI, $15,706 to $15,878) in 2002 to $23,650 (95% CI, $23,544 to $23,755) in 2013 (an increase of $7,858 or 49.8%). If length of stay were set at the 2002 mean, the growth in cost for total knee arthroplasty would have been 70.8% instead of 52.4% as observed, and the growth in cost for total hip arthroplasty would have been 67.4% instead of 49.8% as observed. Hospital costs for joint replacement increased from 2002 to 2013, but were attenuated by reducing inpatient length of stay. With demographic characteristics showing an upward trend in the utilization of joint arthroplasty, including a shift toward younger population groups, reduction in length of stay remains an important target for procedure-level cost containment under emerging payment models.

  14. Evaluating higher doses of Shunthi - Guduchi formulations for safety in treatment of osteoarthritis knees: A Government of India NMITLI arthritis project

    PubMed Central

    Chopra, Arvind; Saluja, Manjit; Tillu, Girish; Venugopalan, Anuradha; Narsimulu, Gumdal; Sarmukaddam, Sanjeev; Patwardhan, Bhushan

    2012-01-01

    Background: Results of an exploratory trial suggested activity trends of Zingiber officinale-Tinopsora cordifolia (platform combination)-based formulations in the treatment of Osteoarthritis (OA) Knees. These formulations were “platform combination+Withania somnifera+Tribulus terrestris” (formulation B) and “platform combination+Emblica officinale” (formulation C). This paper reports safety of these formulations when used in higher doses (1.5–2 times) along with Sallaki Guggul and Bhallataka Parpati (a Semecarpus anacardium preparation). Materials and Methods: Ninety-two patients with symptomatic OA knees were enrolled in a 6 weeks investigator blind, randomized parallel efficacy 4-arm multicenter drug trial. The 4 arms were (I) formulation B, 2 t.i.d.; (II) formulation B, 2 q.i.d.; (III) platform combination+Sallaki Guggul; (IV) Bhallataka Parpati+formulation C. A detailed enquiry was carried out for adverse events (AE) and drug toxicity as per a priori check list and volunteered information. Laboratory evaluation included detailed hematology and metabolic parameters. Patients were examined at baseline, first and fourth weeks, and on completion. Standard statistical program (SPSS version 12.5) was used for analysis. Results: None of the patients reported serious AE or withdrew due to any drug-related toxicity. Mild gut–related (mostly epigastric burning) AE was reported. A mild increase in liver enzymes [serum glutamic pyruvate transaminase (SGPT), serum glutamic oxaloacetic transaminase (SGOT)] without any other hepatic abnormality was reported in 2 patients (group IV). Other laboratory parameters remained normal. The mean improvement in active pain visual analog scale (1.4, CI 0.5–2.22), WOMAC (functional activity questionnaire) pain score (1.37, CI 0.22–2.5), and urinary C-TAX (cartilage collagen breakdown product) assay was maximum (NS) in group IV. Lower dose group I showed numerically superior improvement compared with higher dose group II. Conclusion: The results suggested that despite higher doses, standardized Ayurvedic formulations demonstrated a good safety profile. An improved efficacy and likely chondroprotective effect was shown by group IV intervention. A confirmatory drug trial with adequate power and sample size was planned based on the learning from this trial. PMID:22529679

  15. Evaluating higher doses of Shunthi - Guduchi formulations for safety in treatment of osteoarthritis knees: A Government of India NMITLI arthritis project.

    PubMed

    Chopra, Arvind; Saluja, Manjit; Tillu, Girish; Venugopalan, Anuradha; Narsimulu, Gumdal; Sarmukaddam, Sanjeev; Patwardhan, Bhushan

    2012-01-01

    Results of an exploratory trial suggested activity trends of Zingiber officinale-Tinopsora cordifolia (platform combination)-based formulations in the treatment of Osteoarthritis (OA) Knees. These formulations were "platform combination+Withania somnifera+Tribulus terrestris" (formulation B) and "platform combination+Emblica officinale" (formulation C). This paper reports safety of these formulations when used in higher doses (1.5-2 times) along with Sallaki Guggul and Bhallataka Parpati (a Semecarpus anacardium preparation). Ninety-two patients with symptomatic OA knees were enrolled in a 6 weeks investigator blind, randomized parallel efficacy 4-arm multicenter drug trial. The 4 arms were (I) formulation B, 2 t.i.d.; (II) formulation B, 2 q.i.d.; (III) platform combination+Sallaki Guggul; (IV) Bhallataka Parpati+formulation C. A detailed enquiry was carried out for adverse events (AE) and drug toxicity as per a priori check list and volunteered information. Laboratory evaluation included detailed hematology and metabolic parameters. Patients were examined at baseline, first and fourth weeks, and on completion. Standard statistical program (SPSS version 12.5) was used for analysis. None of the patients reported serious AE or withdrew due to any drug-related toxicity. Mild gut-related (mostly epigastric burning) AE was reported. A mild increase in liver enzymes [serum glutamic pyruvate transaminase (SGPT), serum glutamic oxaloacetic transaminase (SGOT)] without any other hepatic abnormality was reported in 2 patients (group IV). Other laboratory parameters remained normal. The mean improvement in active pain visual analog scale (1.4, CI 0.5-2.22), WOMAC (functional activity questionnaire) pain score (1.37, CI 0.22-2.5), and urinary C-TAX (cartilage collagen breakdown product) assay was maximum (NS) in group IV. Lower dose group I showed numerically superior improvement compared with higher dose group II. The results suggested that despite higher doses, standardized Ayurvedic formulations demonstrated a good safety profile. An improved efficacy and likely chondroprotective effect was shown by group IV intervention. A confirmatory drug trial with adequate power and sample size was planned based on the learning from this trial.

  16. In vivo six-degree-of-freedom knee-joint kinematics in overground and treadmill walking following total knee arthroplasty.

    PubMed

    Guan, Shanyuanye; Gray, Hans A; Schache, Anthony G; Feller, Julian; de Steiger, Richard; Pandy, Marcus G

    2017-08-01

    No data are available to describe six-degree-of-freedom (6-DOF) knee-joint kinematics for one complete cycle of overground walking following total knee arthroplasty (TKA). The aims of this study were firstly, to measure 6-DOF knee-joint kinematics and condylar motion for overground walking following TKA; and secondly, to determine whether such data differed between overground and treadmill gait when participants walked at the same speed during both tasks. A unique mobile biplane X-ray imaging system enabled accurate measurement of 6-DOF TKA knee kinematics during overground walking by simultaneously tracking and imaging the joint. The largest rotations occurred for flexion-extension and internal-external rotation whereas the largest translations were associated with joint distraction and anterior-posterior drawer. Strong associations were found between flexion-extension and adduction-abduction (R 2  = 0.92), joint distraction (R 2  = 1.00), and anterior-posterior translation (R 2  = 0.77), providing evidence of kinematic coupling in the TKA knee. Although the measured kinematic profiles for overground walking were grossly similar to those for treadmill walking, several statistically significant differences were observed between the two conditions with respect to temporo-spatial parameters, 6-DOF knee-joint kinematics, and condylar contact locations and sliding. Thus, caution is advised when making recommendations regarding knee implant performance based on treadmill-measured knee-joint kinematic data. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 35:1634-1643, 2017. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  17. The role of the deep medial collateral ligament in controlling rotational stability of the knee.

    PubMed

    Cavaignac, Etienne; Carpentier, Karel; Pailhé, Regis; Luyckx, Thomas; Bellemans, Johan

    2015-10-01

    The tibial insertion of the deep medial collateral ligament (dMCL) is frequently sacrificed when the proximal tibial cut is performed during total knee arthroplasty. The role of the dMCL in controlling the knee's rotational stability is still controversial. The aim of this study was to quantify the rotational laxity induced by an isolated lesion of the dMCL as it occurs during tibial preparation for knee arthroplasty. An isolated resection of the deep MCL was performed in 10 fresh-frozen cadaver knees. Rotational laxity was measured during application of a standard 5.0 N.m rotational torque. Maximal tibial rotation was measured at different knee flexion angles using an image-guided navigation system (Medivision Surgetics system, Praxim, Grenoble, France) before and after dMCL resection. In all cases, internal and external tibial rotation increased after dMCL resection. Total rotational laxity increased significantly for all knee flexion angles, with an average difference of +7.8° (SD 5.7) with the knee in extension, +8.9° (SD 1.9) in 30° flexion, +7° (SD 2.9) in 60° flexion and +5.3° (SD 2.8) in 90° flexion. Sacrificing the tibial insertion of the deep MCL increases rotational laxity of the knee by 5°-9°, depending on the knee flexion angle. Based on our findings, new surgical techniques and implants that preserve the dMCL insertion such as tibial inlay components should be developed. Further clinical evaluations are necessary.

  18. Residual Symptoms and Function After Unicompartmental and Total Knee Arthroplasty: Comparable to Normative Controls?

    PubMed

    Nam, Denis; Berend, Michael E; Nunley, Ryan M; Della Valle, Craig J; Berend, Keith R; Lombardi, Adolph V; Barrack, Robert L

    2016-10-01

    Whether patient-reported symptoms and function after total knee arthroplasty (TKA) and medial unicompartmental knee arthroplasty (UKA) compare favorably to similar individuals without a diagnosis of knee pathology has not been investigated. A retrospective, multicenter study was designed in which 4 centers contributed patients between ages 18 and 80 years undergoing knee arthroplasty. Data were collected by an independent, third-party survey center that administered a questionnaire assessing patient satisfaction and function. The survey center identified a "control" population of the same age range using a "random digit dial call method" with no prior knee interventions or major problems with their knees limiting their activity. Comparisons were performed using multivariate logistic regression analyses accounting for differences in demographic variables among the 3 cohorts. Overall, 1456 TKAs, 476UKAs, and 409 controls were included for analysis. Controls reported a surprisingly high incidence of pain (30%), a limp (26%), stiffness (22%), and noise (21%) in their knee. However, the likelihood of reported noise (odds ratio [OR], 1.3), swelling (OR, 1.4), stiffness (OR, 1.8), and difficulty getting in and out of a chair (OR, 2.5) was increased after TKA vs controls (P < .001-.03). The likelihood of swelling (OR, 1.8), stiffness (OR, 1.5), and difficulty getting in and out of a chair (OR, 1.7) was increased after UKA vs controls (P = .002-.005). When interviewed by an independent, third party, a substantial percentage of control patients reported the presence of knee symptoms, but to a lesser degree than patients after a knee arthroplasty. Copyright © 2016 Elsevier Inc. All rights reserved.

  19. Incidence and variance of knee injuries in elite college football players.

    PubMed

    Bradley, James; Honkamp, Nicholas J; Jost, Patrick; West, Robin; Norwig, John; Kaplan, Lee D

    2008-06-01

    Knee injuries are among the most common musculoskeletal injuries in US football players. The literature includes little information about the role of player position and risk for knee injury. We hypothesized that the incidence of knee injury in elite collegiate US football players is high and that type of injury varies by player position. We evaluated 332 elite collegiate US football players at the 2005 National Football League Combine. All players underwent radiographic examinations, including plain x-rays and/or magnetic resonance imaging when necessary. All knee pathologic conditions and surgical procedures were recorded. Data were analyzed by player position to detect any trends. Fifty-four percent (179) of the 332 players had a history of knee injury; knee injuries totaled 233 (1.3/player injured). Eighty-six players (25.9%) had a total of 114 surgeries. The most common injuries were medial collateral ligament injury (n = 79), meniscal injury (n = 51), and anterior cruciate ligament (ACL) injury (n = 40). The most common surgeries were arthroscopic meniscectomy (n = 39), ACL reconstruction (n = 35), and arthroscopic meniscal repair (n = 13). A history of knee injury was most common in defensive linemen (68% of players), tight ends (57%), and offensive linemen (57%). Knee surgery was more commonly performed on running backs (36%) and linebackers (34%). There were no significant associations between type or frequency of specific injuries with regard to player position. Knee injuries are common injuries in elite collegiate football players, and one fourth of these players undergo surgical procedures. However, there were no statistically significant differences in type or frequency of injuries by player position.

  20. Knee Replacement: MedlinePlus Health Topic

    MedlinePlus

    ... Surgery for a Total Knee System (BroadcastMed) - University Orthopedics Center, State College, PA, 8/21/2014 Statistics and Research Commonly Prescribed Blood Thinner Associated with Higher Risk ...

  1. Osteotomy around young deformed knees: 38-year super-long-term follow-up to detect osteoarthritis.

    PubMed

    Koshino, Tomihisa

    2010-02-01

    Since 1969 corrective osteotomy has been performed at our institute in young patients (under 40 years) with bowlegs, knock knees and flexion or rotational deformities around the knee. Fifty-seven knees (29 left, 28 right) of 45 patients (19 boys, 26 girls) were followed-up for a period ranging from 30 to 38 years in seven patients with seven knees, from 20 to 29 years in nine patients with 11 knees, and from ten to 19 years in 29 patients with 39 knees. Supracondylar femoral osteotomy was performed on 12 knees (11 patients), high tibial osteotomy above the tibial tuberosity on eight knees (six patients) and below the tuberosity on 37 knees (28 patients). At the final follow-up (age range 42-73 years), all of the deformities were satisfactorily corrected, with no symptoms apart from nine knees, seven of which had dull pain after strenuous sport with osteophytes, etc. in the radiograph. Total knee arthroplasty was performed in the remaining two knees, at ten and 26 years, respectively, after the initial osteotomy. Osteoarthritis developed in the contralateral knee to the initial osteotomy in two patients after 34 years at age 73 and after 33 years at age 67.

  2. Non-Sagittal Knee Joint Kinematics and Kinetics during Gait on Level and Sloped Grounds with Unicompartmental and Total Knee Arthroplasty Patients

    PubMed Central

    Komnik, Igor; David, Sina; Weiss, Stefan; Potthast, Wolfgang

    2016-01-01

    After knee arthroplasty (KA) surgery, patients experience abnormal kinematics and kinetics during numerous activities of daily living. Biomechanical investigations have focused primarily on level walking, whereas walking on sloped surfaces, which is stated to affect knee kinematics and kinetics considerably, has been neglected to this day. This study aimed to analyze over-ground walking on level and sloped surfaces with a special focus on transverse and frontal plane knee kinematics and kinetics in patients with KA. A three-dimensional (3D) motion analysis was performed by means of optoelectronic stereophogrammetry 1.8 ± 0.4 years following total knee arthroplasty (TKA) and unicompartmental arthroplasty surgery (UKA). AnyBody™ Modeling System was used to conduct inverse dynamics. The TKA group negotiated the decline walking task with reduced peak knee internal rotation angles compared with a healthy control group (CG). First-peak knee adduction moments were diminished by 27% (TKA group) and 22% (UKA group) compared with the CG during decline walking. No significant differences were detected between the TKA and UKA groups, regardless of the locomotion task. Decline walking exposed apparently more abnormal knee frontal and transverse plane adjustments in KA patients than level walking compared with the CG. Hence, walking on sloped surfaces should be included in further motion analysis studies investigating KA patients in order to detect potential deficits that might be not obvious during level walking. PMID:28002437

  3. Circuit training enhances function in patients undergoing total knee arthroplasty: a retrospective cohort study.

    PubMed

    Hsu, Wei-Hsiu; Hsu, Wei-Bin; Shen, Wun-Jer; Lin, Zin-Rong; Chang, Shr-Hsin; Hsu, Robert Wen-Wei

    2017-10-19

    The number of patients receiving total knee arthroplasty (TKA) has been rising every year due to the aging population and the obesity epidemic. Post-operative rehabilitation is important for the outcome of TKA. A series of 34 patients who underwent primary unilateral TKA was retrospectively collected and divided into either exercise group (n = 16) and control group (n = 18). The exercise group underwent a 24-week course of circuit training beginning 3 months after total knee arthroplasty (TKA). The effect of circuit training on TKA patients in terms of motion analysis, muscle strength testing, Knee injury and Osteoarthritis Outcomes Score (KOOS) questionnaire and patient-reported outcome measurement Short-Form Health Survey (SF-36) at the pre-operation, pre-exercise, mid-exercise, and post-exercise. Motion analysis revealed the stride length, step velocity, and excursion of active knee range of motion significantly improved in the exercise group when compared to those in the control group. KOOS questionnaire showed a greater improvement in pain, ADL, and total scores in the exercise group. The SF-36 questionnaire revealed a significant improvement in general health, bodily pain, social function, and physical components score in the exercise group. The post-operative circuit training intervention can facilitate recovery of knee function and decrease the degree of pain in the TKA and might be considered a useful adjunct rehabilitative modality. The ultimate influence of circuit training on TKA needs further a prospective randomized clinical trial study and long-term investigation. NCT02928562.

  4. Mobile-bearing total knee arthroplasty: a full traumatic rotation of 180°.

    PubMed

    Sudanese, Alessandra; Castiello, Emanuela; Affatato, Saverio

    2013-06-25

    From February 2008 to September 2012 we implanted 204 mobile-bearing knee prostheses in 192 patients. All the prostheses were cemented (both femoral and tibial components), and the patella was not replaced. Only one early complication of the implants (1/204 = 0.004%) occurred after a traumatic event as a full 180° rotation of the mobile-bearing polyethylene insert. A 78-year-old woman presented with swelling and severe pain at her right knee. This traumatic event was the only case among our mobile-bearing insert patients. 
The failed polyethylene inserts were retrieved and studied using a scanning electron microscope (SEM, ZEISS EVO 50 EP, Cambridge, UK) operating at 20 kV. 
Scratching and pitting were found on the UHMWPE insert perpendicular to the machining tracks for the concave surface. SEM micrographs of the insert showed burnishing on the concave surfaces and longitudinal scratches were clearly detectable and well-marked on the analyzed surfaces. 
A traumatic, fully rotating, polyethylene insert is rare and our case is the first report describing a traumatic event with a complete 180 degree rotation mobile-bearing in a total knee prosthesis. 
In the literature few reports discuss clinical outcomes after total knee arthroplasty in patients with Parkinson's disease and they cite mixed results. However, some authors suggest that posterior-stabilized and cruciate-retaining TKA should work well while others prefer cruciate-retaining, condylar constrained kinetics, or hinged devices. Although we did not implant a posterior-stabilized mobile-bearing total knee prosthesis or a constrained prosthesis, we obtained good clinical and radiological results at the 2-year followup.

  5. A randomised, controlled trial of circumpatellar electrocautery in total knee replacement without patellar resurfacing: a concise follow-up at a mean of 3.7 years.

    PubMed

    van Jonbergen, H P W; Scholtes, V A B; Poolman, R W

    2014-04-01

    In the absence of patellar resurfacing, we have previously shown that the use of electrocautery around the margin of the patella improved the one-year clinical outcome of total knee replacement (TKR). In this prospective randomised study we compared the mean 3.7 year (1.1 to 4.2) clinical outcomes of 300 TKRs performed with and without electrocautery of the patellar rim: this is an update of a previous report. The overall prevalence of anterior knee pain was 32% (95% confidence intervals [CI] 26 to 39), and 26% (95% CI 18 to 35) in the intervention group compared with 38% (95% CI 29 to 48) in the control group (chi-squared test; p = 0.06). The overall prevalence of anterior knee pain remained unchanged between the one-year and 3.7 year follow-up (chi-squared test; p = 0.12). The mean total Western Ontario McMasters Universities Osteoarthritis Indices and the American Knee Society knee and function scores at 3.7 years' follow-up were similar in the intervention and control groups (repeated measures analysis of variance p = 0.43, p = 0.09 and p = 0.59, respectively). There were no complications. A total of ten patients (intervention group three, control group seven) required secondary patellar resurfacing after the first year. Our study suggests that the improved clinical outcome with electrocautery denervation compared with no electrocautery is not maintained at a mean of 3.7 years' follow-up.

  6. Hip and knee extensor moments predict vertical jump height in adolescent girls.

    PubMed

    Ford, Kevin R; Myer, Gregory D; Brent, Jensen L; Hewett, Timothy E

    2009-07-01

    Biomechanical factors, such as hip and knee extensor moments, related to drop jump (DJ) performance have not been investigated in adolescent girls. The purpose of this study was to determine the key independent biomechanical variables that predict overall vertical jump performance in adolescent girls. Sixteen high school adolescent girls from club-sponsored and high school-sponsored volleyball teams performed DJ at 3 different drop heights (15, 30, and 45 cm). A motion analysis system consisting of 10 digital cameras and a force platform was used to calculate vertical jump height, joint angles, and joint moments during the tasks. A multiple linear regression was used to determine the biomechanical parameters that were best predictive of vertical jump height at each box drop distance. The 2 predictor variables in all 3 models were knee and hip extensor moments. The models predicted 82.9, 81.9, and 88% of the vertical jump height variance in the 15, 30, and 45 cm trials, respectively. The results of the investigation indicate that knee and hip joint moments are the main contributors to vertical jump height during the DJ in adolescent girls. Strength and conditioning specialists attempting to improve vertical jump performance should target power and strength training to the hip and knee extensors in their athletes.

  7. CRPS Knee: How frequently encountered in differential diagnosis of Knee pain?

    PubMed

    Aggarwal, Aakanksha; Agarwal, Anil

    2018-04-13

    We have read with great interest the paper by Catelijne M. van Bussel [1] recently published in Pain Practice. I wish to congratulate the authors for their valuable contributions. In the said article, 12 patients who had complex regional pain syndrome confined to the knee have been included. Though reports have been published involving primarily the knee after total knee arthroplasty [2,3] the incidence of CRPS knee following trauma or otherwise is not well appreciated. We would have appreciated if presence or absence of any inciting event for the development CRPS knee in these 12 patients could be mentioned, which could be helpful in a better diagnosis and management of the patients with CRPS knee. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  8. Comparison of intraoperative anthropometric measurements of the proximal tibia and tibial component in total knee arthroplasty.

    PubMed

    Miyatake, Naohisa; Sugita, Takehiko; Aizawa, Toshimi; Sasaki, Akira; Maeda, Ikuo; Kamimura, Masayuki; Fujisawa, Hirokazu; Takahashi, Atsushi

    2016-09-01

    Precise matching of the tibial component and resected bony surfaces and proper rotational implanting of the tibial component are crucial for successful total knee arthroplasty. We aimed to analyze the exact anthropometric proximal tibial data of Japanese patients undergoing total knee arthroplasty and correlate the measurements with the dimensions of current total knee arthroplasty systems. A total of 703 knees in 566 Japanese patients who underwent total knee arthroplasty for osteoarthritis were included. The bone resection in the proximal tibia was performed perpendicular to the tibial axis in the frontal plane. Measurements of the proximal tibia were intraoperatively obtained after proximal tibial preparation. There were significant positive correlations between the lateral anteroposterior and medial anteroposterior and mediolateral dimensions. A progressive decrease in the mediolateral/lateral anteroposterior ratio with an increasing lateral anteroposterior dimension or the mediolateral/anteroposterior ratio with an increasing anteroposterior dimension was observed. The lateral anteroposterior dimension was smaller than the medial anteroposterior dimension by a mean of 4.8 ± 2.0 mm. The proximal tibia exhibited asymmetry between the lateral and medial plateaus. A comparison of the morphological data and dimensions of the implants, one of which was a symmetric tibial component (NexGen) and the others were asymmetric (Genesis II and Persona), indicated that an asymmetric tibial component could be beneficial to maximize tibial plateau coverage. This study provided important reference data for designing a proper tibial component for Japanese people. The proximal tibial cut surface was asymmetric. There was wide dispersion in the lateral anteroposterior, medial anteroposterior, and mediolateral dimensions depending on the patient. Our data showed that the tibial components of the Genesis II and Persona rather than that of the NexGen may be preferable for Japanese people because of their asymmetric design. Copyright © 2016 The Japanese Orthopaedic Association. Published by Elsevier B.V. All rights reserved.

  9. Autologous blood transfusion in total knee replacement surgery.

    PubMed

    Sarkanović, Mirka Lukić; Gvozdenović, Ljiljana; Savić, Dragan; Ilić, Miroslav P; Jovanović, Gordana

    2013-03-01

    Total knee replacement (TKR) surgery is one of the most frequent and the most extensive procedures in orthopedic surgery, accompanied with some serious complications. Perioperative blood loss is one of the most serious losses, so it is vital to recognize and treat such losses properly. Autologous blood transfusion is the only true alternative for the allogeneic blood. The aim of this study was to to examine if autologous blood transfusion reduces usage of allogenic blood in total knee replacement surgery, as well as to examine possible effect of autologous blood transfusion on postoperative complications, recovery and hospital stay of patients after total knee replacement surgery. During the controlled, prospective, randomised study we compared two groups of patients (n = 112) with total prosthesis implanted in their knee. The group I consisted of the patients who received the transfusion of other people's (allogeneic) blood (n = 57) and the group II of the patients whose blood was collected postoperatively and then given them [their own (autologous) blood] (n = 55). The transfusion trigger for both groups was hemoglobin level of 85 g/L. In the group of patients whose blood was collected perioperatively only 9 (0.9%) of the patients received transfusion of allogeneic blood, as opposed to the control group in which 98.24% of the patients received the transfusion of allogeneic blood (p < or = 0.01). The patients whose blood was collected stayed in hospital for 6.18 days, while the patients of the control group stayed 7.67 days (p < 0.01). Autologous blood transfusion is a very effective method for reducing consumption of allogenic blood and thus, indirectly for reducing all complications related to allogenic blood transfusion. There is also a positive influence on postoperative recovery after total knee replacement surgery due to the reduction of hospital stay, and indirectly on the reduction of hospital costs.

  10. Soft tissue and intra-articular injection of bupivacaine, epinephrine, and morphine has a beneficial effect after total knee arthroplasty.

    PubMed

    Lombardi, Adolph V; Berend, Keith R; Mallory, Thomas H; Dodds, Kathleen L; Adams, Joanne B

    2004-11-01

    The purpose of this study was to determine if an intraoperative intraarticular and soft-tissue injection of local anaesthetic, epinephrine, and morphine has a beneficial effect for total knee arthroplasty. A control group of 138 patients (181 knees) received no intraoperative injection. The study group of 171 patients (197 knees) received intraoperative injection of 0.25% bupivacaine with epinephrine and morphine with 2/3 injected into the soft tissues and 1/3 injected into the joint. Patients having bilateral simultaneous procedures received a divided dose. The pain treatment protocol otherwise was identical. Pain, sedation, rescue narcotic usage, narcotic reversal and blood loss were examined. Pain levels during the immediate postoperative period, blood loss, and bleeding indices were reduced with injection. Considerably more control patients required rescue doses of narcotics. Preemptive analgesia with soft tissue and intra-articular injection of long-acting local anesthetic with epinephrine and morphine provides better pain control in the immediate postoperative period, decreases blood loss, and decreases the need for rescue narcotics and reversal agents. This simple, inexpensive method provides an effective adjunct to a multimodal approach in improving the postoperative course of primary total knee arthroplasty.

  11. Physiotherapy in the management of total knee arthroplasty: a review.

    PubMed

    Akodu, A K; Giwa, S O; Akinbo, S R A; Ahmed, U A

    2011-01-01

    Although total knee arthroplasty (TKA) is considered the treatment of choice for patients with intractable pain and substantial functional disabilities who have not had acceptable relief and functional improvement after conservative treatment. It was found out that patients with total knee arthroplasty need physiotherapy intervention for pre-operative and post-operative management. To take a critical look at the importance of TKA following destruction of the knee joint, its indications and contraindications and to ascertain the current trend involved in the physiotherapy management of TKA. The current literature materials on physiotherapy management of TKA was reviewed. The aim of treatment is to maximize functionality and independence and to minimize complication such as deep vein thrombosis and pulmonary embolism by relieving pain using cryotherapy, improving range of motion with mobilization techniques, muscle strengthening, therapeutic exercise, transfer training, gait training and training of activities of daily living. These are administered as home programme or in organized groups led by a physiotherapist and has been shown to improve outcome related to physical activity after knee joint arthroplasty. It was concluded that interventions, including physiotherapy and functional exercises after discharge, is still beneficial after TKA.

  12. Reduced Operating Time but Not Blood Loss With Cruciate Retaining Total Knee Arthroplasty

    PubMed Central

    Vermesan, Dinu; Trocan, Ilie; Prejbeanu, Radu; Poenaru, Dan V; Haragus, Horia; Gratian, Damian; Marrelli, Massimo; Inchingolo, Francesco; Caprio, Monica; Cagiano, Raffaele; Tatullo, Marco

    2015-01-01

    Background There is no consensus regarding the use of retaining or replacing cruciate implants for patients with limited deformity who undergo a total knee replacement. Scope of this paper is to evaluate whether a cruciate sparing total knee replacement could have a reduced operating time compared to a posterior stabilized implant. Methods For this purpose, we performed a randomized study on 50 subjects. All procedures were performed by a single surgeon in the same conditions to minimize bias and only knees with a less than 20 varus deviation and/or maximum 15° fixed flexion contracture were included. Results Surgery time was significantly shorter with the cruciate retaining implant (P = 0.0037). The mean duration for the Vanguard implant was 68.9 (14.7) and for the NexGen II Legacy was 80.2 (11.3). A higher range of motion, but no significant Knee Society Scores at 6 months follow-up, was used as controls. Conclusions In conclusion, both implants had the potential to assure great outcomes. However, if a decision has to be made, choosing a cruciate retaining procedure could significantly reduce the surgical time. When performed under tourniquet, this gain does not lead to reduced blood loss. PMID:25584102

  13. Does joint line elevation after revision knee arthroplasty affect tibio-femoral kinematics, contact pressure or collateral ligament lengths? An in vitro analysis

    PubMed Central

    Kowalczewski, Jacek B.; Chevalier, Yan; Okon, Tomasz; Innocenti, Bernardo; Bellemans, Johan

    2015-01-01

    Introduction Correct restoration of the joint line is generally considered as crucial when performing total knee arthroplasty (TKA). During revision knee arthroplasty however, elevation of the joint line occurs frequently. The general belief is that this negatively affects the clinical outcome, but the reasons are still not well understood. Material and methods In this cadaveric in vitro study the biomechanical consequences of joint line elevation were investigated using a previously validated cadaver model simulating active deep knee squats and passive flexion-extension cycles. Knee specimens were sequentially tested after total knee arthroplasty with joint line restoration and after 4 mm joint line elevation. Results The tibia rotated internally with increasing knee flexion during both passive and squatting motion (range: 17° and 7° respectively). Joint line elevation of 4 mm did not make a statistically significant difference. During passive motion, the tibia tended to become slightly more adducted with increasing knee flexion (range: 2°), while it went into slighlty less adduction during squatting (range: –2°). Neither of both trends was influenced by joint line elevation. Also anteroposterior translation of the femoral condyle centres was not affected by joint line elevation, although there was a tendency for a small posterior shift (of about 3 mm) during squatting after joint line elevation. In terms of kinetics, ligaments lengths and length changes, tibiofemoral contact pressures and quadriceps forces all showed the same patterns before and joint line elevation. No statistically significant changes could be detected. Conclusions Our study suggests that joint line elevation by 4 mm in revision total knee arthroplasty does not cause significant kinematic and kinetic differences during passive flexion/extension movement and squatting in the tibio-femoral joint, nor does it affect the elongation patterns of collateral ligaments. Therefore, clinical problems after joint line elevation are probably situated in the patello-femoral joint or caused by joint line elevation of more than 4 mm. PMID:25995746

  14. Outcome following subluxation of mobile articulating spacers in two-stage revision total knee arthroplasty.

    PubMed

    Lanting, Brent A; Lau, Adrian; Teeter, Matthew G; Howard, James L

    2017-03-01

    Infection after total knee arthroplasty (TKA) is a severe complication. It is usually treated with two-stage revision and implantation of a cement spacer. Few studies describe the complications associated with a mobile articulating spacer. This study examined the subluxation of articulating antibiotic spacers in knees and correlated it with prospectively collected early outcome scores after implantation of a revision prosthesis. Staged revisions for 72 infected primary total knee arthroplasties between 2004 and 2012 were examined. The mean age of the patients was 70.2 ± 10.8 years, with 40 right and 32 left knees. Sagittal and coronal subluxation was measured using radiographs prior to second-stage revision and grouped to be within (Group 1) or outside (Group 2) one standard deviation from the mean. Medical Outcomes Study Short Form-12 (SF-12), Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) and Knee Society Score (KSS) were obtained via patient-administered questionnaire. Statistical analysis was carried out to look at the correlation between subluxation and outcome. Significant improvements were observed between the interim outcome scores prior to implantation of a revision prosthesis and scores obtained after second-stage revision. Debonding occurred in 5.6%, and one dislocation was found. Mean coronal subluxation was 4.8 ± 5.5% of the tibia width, in the lateral direction. Coronal subluxation did not affect SF12, WOMAC or KSS outcome scores. Mean sagittal subluxation was 6.1 ± 16.4% posteriorly. However, sagittal subluxation had a significant influence on Knee Society Scores, with Group 2 having a lower mean Knee Society Function Score of 39.3 than Group 1 (60.2) (p = 0.045). Sagittal subluxation did not affect SF12 or WOMAC scores. Sagittal subluxation of the knee may influence the early to midterm outcome scores following a staged revision TKA for infection.

  15. What Are the Prognostic Factors for Radiographic Progression of Knee Osteoarthritis? A Meta-analysis.

    PubMed

    Bastick, Alex N; Belo, Janneke N; Runhaar, Jos; Bierma-Zeinstra, Sita M A

    2015-09-01

    A previous systematic review on prognostic factors for knee osteoarthritis (OA) progression showed associations for generalized OA and hyaluronic acid levels. Knee pain, radiographic severity, sex, quadriceps strength, knee injury, and regular sport activities were not associated. It has been a decade since the literature search of that review and many studies have been performed since then investigating prognostic factors for radiographic knee OA progression. The purpose of this study is to provide an updated systematic review of available evidence regarding prognostic factors for radiographic knee OA progression. We searched for observational studies in MEDLINE and EMBASE. Key words were: knee, osteoarthritis (or arthritis, or arthrosis, or degenerative joint disease), progression (or prognosis, or precipitate, or predictive), and case-control (or cohort, or longitudinal, or follow-up). Studies fulfilling the inclusion criteria were assessed for methodologic quality according to established criteria for reviews on prognostic factors in musculoskeletal disorders. Data were extracted and results were pooled if possible or summarized according to a best-evidence synthesis. A total of 1912 additional articles were identified; 43 met our inclusion criteria. The previous review contained 36 articles, thus providing a new total of 79 articles. Seventy-two of the included articles were scored high quality, the remaining seven were low quality. The pooled odds ratio (OR) of two determinants showed associations with knee OA progression: baseline knee pain (OR, 2.38 [95% CI, 1.74-3.27) and Heberden nodes (OR, 2.66 [95% CI, 1.46-8.84]). Our best-evidence synthesis showed strong evidence that varus alignment, serum hyaluronic acid, and tumor necrosis factor-α are associated with knee OA progression. There is strong evidence that sex, former knee injury, quadriceps strength, smoking, running, and regular performance of sports are not associated with knee OA progression. Evidence for the majority of determined associations, however, was limited, conflicting, or inconclusive. Baseline knee pain, presence of Heberden nodes, varus alignment, and high levels of serum markers hyaluronic acid and tumor necrosis factor-α predict knee OA progression. Sex, knee injury, and quadriceps strength, among others, did not predict knee OA progression. Large variation remains in definitions of knee OA and knee OA progression. Clinical studies should use more consistent definitions of these factors to facilitate data pooling by future meta-analyses.

  16. Revision of Infected Total Knee Arthroplasty: Two-Stage Reimplantation Using an Antibiotic-Impregnated Static Spacer

    PubMed Central

    Almeida, Fernando; Renovell, Pablo; Morante, Elena; López, Raúl

    2013-01-01

    Background A two-stage revision remains as the "gold standard" treatment for chronically infected total knee arthroplasties. Methods Forty-five septic knee prostheses were revised with a minimum follow-up of 5 years. Static antibiotic-impregnated cement spacers were used in all cases. Intravenous antibiotics according to sensitivity test of the culture were applied during patients' hospital stay. Oral antibiotics were given for another 5 weeks. Second-stage surgery was undertaken after control of infection with normal erythrocyte sedimentation rate and C-reactive protein values. Extensile techniques were used if needed and metallic augments were employed for bone loss in 32 femoral and 29 tibial revisions. Results The average interval between the first-stage resection and reimplantation was 4.4 months. Significant improvement was obtained with respect to visual analog scale pain and clinical and functional scores, and infection was eradicated in 95.6% of cases following a two-stage revision total knee arthroplasty. Radiographic evaluation showed suitable alignment without signs of mechanical loosening. Conclusions This technique is a reasonable procedure to eradicate chronic infection in knee arthroplasty and provides proper functional and clinical results. However, it sometimes requires extensile surgical approaches that could imply arduous surgeries. Metallic augments with cementless stems available in most of the knee revision systems are a suitable alternative to handle bone deficiencies, avoiding the use of bone allografts with its complications. PMID:24009903

  17. Assessing coronal laxity in extension and flexion at a minimum of 10 years after primary total knee arthroplasty.

    PubMed

    Yoshihara, Yasushi; Arai, Yuji; Nakagawa, Shuji; Inoue, Hiroaki; Ueshima, Keiichiro; Fujiwara, Hiroyoshi; Oda, Ryo; Taniguchi, Daigo; Kubo, Toshikazu

    2016-08-01

    Favourable long-term results after total knee arthroplasty (TKA) require appropriate soft tissue balance. However, the relationships between long-term results after TKA surgery and mediolateral laxities at extension and at 90° flexion remain unknown. This study therefore quantitatively assessed ligament balance at extension and at 90° knee flexion at least 10 years after primary TKA, as well as clarifying the relationships between long-term outcomes and mediolateral laxities. This study included 49 knees (19 CR type and 30 PS type) of 33 patients followed up for at least 10 years after TKA at our hospital. Plain radiographs were obtained with about 150 N of varus or valgus stress using a Telos arthrometer at extension. At 90° flexion, epicondylar views were obtained under a 1.5-kg load and with about 10 kg of varus or valgus stress. Lateral laxity of about 5° was observed in both extension and flexion, with total laxities of varus and valgus stress each less than 10°. Postoperative clinical outcomes were good, with significant improvements in extension angle, femorotibial angle, and KSS, and no loosening in any knee. Good long-term results of TKA can be obtained with a lateral laxity of about 5°, equivalent to that of healthy knees. III.

  18. Clinical Evaluation of the Root Tear of the Posterior Horn of the Medial Meniscus in Total Knee Arthroplasty for Osteoarthritis

    PubMed Central

    Park, Sang-Jun

    2015-01-01

    Purpose To investigate the incidence of root tears of the posterior horn of the medial meniscus in total knee replacement arthroplasty for knee osteoarthritis and retrospectively analyze clinical results and factors associated with root tears. Materials and Methods There were 197 knees of 140 enrolled patients who had undergone total knee replacement arthroplasty between September 2010 and May 2014. The presence of a root tear of the posterior horn of the medial meniscus was confirmed in all patients. Statistical analysis was performed to investigate the correlation between root tears and the possible factors of meniscal tears including gender, age, severity of symptoms (visual analogue scale [VAS] score and medial joint line tenderness), grade of osteoarthritis (Kellgren-Lawrence grading scale), body mass index (BMI), varus deformity, and mechanical axis deviation. Results Meniscal tears were observed in 154 knees (78.17%). The root tear had correlation with the severity of osteoarthritis (p<0.05), varus deformity (p<0.05), mechanical axis deviation (p<0.05), and BMI (p<0.05). Conclusions Factors considered to represent the severity of osteoarthritis were found to be associated with root tears of the medial meniscus posterior horn. Increased BMI seemed to be associated with the increased incidence of root tears of the medial meniscus posterior horn. PMID:26060607

  19. Revision of infected total knee arthroplasty: two-stage reimplantation using an antibiotic-impregnated static spacer.

    PubMed

    Silvestre, Antonio; Almeida, Fernando; Renovell, Pablo; Morante, Elena; López, Raúl

    2013-09-01

    A two-stage revision remains as the "gold standard" treatment for chronically infected total knee arthroplasties. Forty-five septic knee prostheses were revised with a minimum follow-up of 5 years. Static antibiotic-impregnated cement spacers were used in all cases. Intravenous antibiotics according to sensitivity test of the culture were applied during patients' hospital stay. Oral antibiotics were given for another 5 weeks. Second-stage surgery was undertaken after control of infection with normal erythrocyte sedimentation rate and C-reactive protein values. Extensile techniques were used if needed and metallic augments were employed for bone loss in 32 femoral and 29 tibial revisions. The average interval between the first-stage resection and reimplantation was 4.4 months. Significant improvement was obtained with respect to visual analog scale pain and clinical and functional scores, and infection was eradicated in 95.6% of cases following a two-stage revision total knee arthroplasty. Radiographic evaluation showed suitable alignment without signs of mechanical loosening. This technique is a reasonable procedure to eradicate chronic infection in knee arthroplasty and provides proper functional and clinical results. However, it sometimes requires extensile surgical approaches that could imply arduous surgeries. Metallic augments with cementless stems available in most of the knee revision systems are a suitable alternative to handle bone deficiencies, avoiding the use of bone allografts with its complications.

  20. The effects of two different frequencies of whole-body vibration on knee extensors strength in healthy young volunteers: a randomized trial

    PubMed Central

    Esmaeilzadeh, S.; Akpinar, M.; Polat, S.; Yildiz, A.; Oral, A.

    2015-01-01

    The aim of this study was to investigate the effects of two different frequencies of whole-body vibration (WBV) training on knee extensors muscle strength in healthy young volunteers. Twenty-two eligible healthy untrained young women aged 22-31 years were allocated randomly to the 30-Hz (n=11) and 50-Hz (n=11) groups. They participated in a supervised WBV training program that consisted of 24 sessions on a synchronous vertical vibration platform (peak-to-peak displacement: 2-4 mm; type of exercises: semi-squat, one-legged squat, and lunge positions on right leg; set numbers: 2-24) three times per week for 8 weeks. Isometric and dynamic strength of the knee extensors were measured prior to and at the end of the 8-week training. In the 30-Hz group, there was a significant increase in the maximal voluntary isometric contraction (p=0.039) and the concentric peak torque (p=0.018) of knee extensors and these changes were significant (p<0.05) compared with the 50-Hz group. In addition, the eccentric peak torque of knee extensors was increased significantly in both groups (p<0.05); however, there was no significant difference between the two groups (p=0.873). We concluded that 8 weeks WBV training in 30 Hz was more effective than 50 Hz to increase the isometric contraction and dynamic strength of knee extensors as measured using peak concentric torque and equally effective with 50 Hz in improving eccentric torque of knee extensors in healthy young untrained women. PMID:26636279

  1. [Clinical evaluation of the ceramic femoral component used for reconstruction of total knee replacement].

    PubMed

    Vavrík, P; Landor, I; Denk, F

    2008-12-01

    The study evaluates mid-term results of total knee replacement with a zirconia ceramic (ZrO2) femoral component. The evaluated group comprised 20 knees in 19 patients (4 men and 15 women). In one patient the replacement was performed bilaterally. Two patients had in the contralateral knee the same type of prosthesis with a femoral chrome-cobalt component.The mean age at the time of operation was 65.2 years (range, 38-81 years).The primary indication was 14 times osteoarthritis and 5 times rheumatoid arthritis. The average follow-up period was 6.5 years (range, 2.1-8.5 years). Patients included in the study regardless of age, body mass and the basic diagnosis, agreed with the use of the ceramic femoral component. The evaluation covered a range of motion, mechanical axis, joint stability, pain, swelling, ability to walk on level ground and on stairs, subjective satisfaction (EULAR Knee Chart). Radiograph were assessed at one year intervals in two projections to identify the incidence of radiolucency around the implant. The Kaplan-Meier survival curve was used and compared with the survival curve in identical chrome-cobalt implants. At he final follow-up, 14 knees were evaluated, because 3 patients died without any connection with the implant, in one case the tibial component migrated due to necrosis of the tibial condyle in a patient with RA and two implants had to be revised and replaced due to polyethylene wear. No infection or negative tissue reaction was recorded in the evaluated group. The average flexion range was 109 degrees. All knees were stable and without swelling, in two cases there occurred slight femoropatellar pain. Twelve patients were fully satisfied, 2 patients were satisfied with a certain reservation. The differences in the course of the survival curves of chrome-cobalt and ceramic implants were statistically insignificant. Although the use of zirconia ceramics in vitro reduces the amount of polyethylene wear, the clinical outcomes of total knee replacements as compared to the hip are not convincing. One of the causes may be the substantially different and more complex biomechanics of the knee. Tribology improvement of the femoral ceramic component cannot compensate the deficiencies in the joint balancing in flexion and extension. The economically and technologically demanding production of these implants may be justified in patients with allergies caused by chrome-cobalt components. The results of mid-term follow-up of the use of zirconia ceramic femoral components proved no impact on the improvement of the period of survival of the knee implant. No adverse response to the material or mechanical failure of the ceramic components was encountered. Key words: total knee replacement, zirconia ceramic femoral component, TKR mid-term results, ceramic knee survival curve.

  2. Effectiveness of prolonged use of continuous passive motion (CPM) as an adjunct to physiotherapy following total knee arthroplasty: design of a randomised controlled trial [ISRCTN85759656].

    PubMed

    Lenssen, Anton F; Crijns, Yvonne H F; Waltjé, Eddie M H; Roox, George M; van Steyn, Mike J A; Geesink, Ruud J T; van den Brandt, Piet A; de Bie, Rob A

    2006-02-23

    Adequate and intensive rehabilitation is an important requirement for successful Total Knee Arthroplasty. The primary focus of early rehabilitation is ambulation of patients and regaining range of motion in the knee. Although research suggests that Continuous Passive Motion should be implemented in the first rehabilitation phase following surgery, there is substantial debate about the duration of each session and the total period of CPM application and. A Cochrane review on this topic concluded that short-term use of CPM leads to greater short-term range of motion. It also suggested, however, that future research should concentrate on the treatment period during which CPM should be administered. In a randomised controlled trial we intend to investigate the efficacy of prolonged use of a continuous passive motion (CPM) device in the home situation as an adjunct to standardised physical therapy. The experimental treatment is compared to standardised physical therapy, in patients with osteoarthritis of the knee undergoing Total Knee Arthroplasty (TKA). Efficacy will be assessed in terms of faster improvements in range of motion and functional recovery. Seventy patients with knee osteoarthritis undergoing TKA and experiencing early postoperative flexion impairment (less than 80 degrees of knee flexion at the time of discharge) will be randomised over two treatment groups, a usual care group and an experimental group. The experimental group will receive CPM + physiotherapy for 17 consecutive days after surgery, whereas the usual care group will receive the same treatment during the in-hospital phase (i.e. about four days), followed by physical therapy alone (usual care) in the first two weeks after hospital discharge. From 18 days to three months after discharge, both groups will receive standardised PT. The primary focus of rehabilitation will be functional recovery (e.g. ambulation) and regaining range of motion (ROM) in the knee. Because restricted knee ROM affects functional activities, knee ROM and knee function are regarded as the primary indicators of successful TKA. Potential effects of the intervention under study include rapid return of knee flexion accompanied by earlier return to functional activities of daily life. If patients benefit significantly from prolonged CPM use, this treatment should be added to the standard PT treatment at home. We expect the additional home CPM programme to be more effective than the usual physiotherapy programme, resulting in a difference in ROM of at least 5 degrees , 17 days after surgery. This clinically important difference, with a possible flexion ROM of about 100 degrees , is expected to lead to better functioning in activities of daily life, like walking, and earlier ability to cycle. These advantages should result in earlier and increasing independence.

  3. Effectiveness of prolonged use of continuous passive motion (CPM) as an adjunct to physiotherapy following total knee arthroplasty: Design of a randomised controlled trial [ISRCTN85759656

    PubMed Central

    Lenssen, Anton F; Crijns, Yvonne HF; Waltjé, Eddie MH; Roox, George M; van Steyn, Mike JA; Geesink, Ruud JT; van den Brandt, Piet A; de Bie, Rob A

    2006-01-01

    Background Adequate and intensive rehabilitation is an important requirement for successful Total Knee Arthroplasty. The primary focus of early rehabilitation is ambulation of patients and regaining range of motion in the knee. Although research suggests that Continuous Passive Motion should be implemented in the first rehabilitation phase following surgery, there is substantial debate about the duration of each session and the total period of CPM application and. A Cochrane review on this topic concluded that short-term use of CPM leads to greater short-term range of motion. It also suggested, however, that future research should concentrate on the treatment period during which CPM should be administered. Methods In a randomised controlled trial we intend to investigate the efficacy of prolonged use of a continuous passive motion (CPM) device in the home situation as an adjunct to standardised physical therapy. The experimental treatment is compared to standardised physical therapy, in patients with osteoarthritis of the knee undergoing Total Knee Arthroplasty (TKA). Efficacy will be assessed in terms of faster improvements in range of motion and functional recovery. Seventy patients with knee osteoarthritis undergoing TKA and experiencing early postoperative flexion impairment (less than 80° of knee flexion at the time of discharge) will be randomised over two treatment groups, a usual care group and an experimental group The experimental group will receive CPM + physiotherapy for 17 consecutive days after surgery, whereas the usual care group will receive the same treatment during the in-hospital phase (i.e. about four days), followed by physical therapy alone (usual care) in the first two weeks after hospital discharge. From 18 days to three months after discharge, both groups will receive standardised PT. The primary focus of rehabilitation will be functional recovery (e.g. ambulation) and regaining range of motion (ROM) in the knee. Discussion Because restricted knee ROM affects functional activities, knee ROM and knee function are regarded as the primary indicators of successful TKA. Potential effects of the intervention under study include rapid return of knee flexion accompanied by earlier return to functional activities of daily life. If patients benefit significantly from prolonged CPM use, this treatment should be added to the standard PT treatment at home. We expect the additional home CPM programme to be more effective than the usual physiotherapy programme, resulting in a difference in ROM of at least 5°, 17 days after surgery. This clinically important difference, with a possible flexion ROM of about 100°, is expected to lead to better functioning in activities of daily life, like walking, and earlier ability to cycle. These advantages should result in earlier and increasing independence. PMID:16504087

  4. Location of the Common Peroneal Nerve in Valgus Knees-Is the Reported Safe Zone for Well-Aligned Knees Applicable?

    PubMed

    Yang, Dejin; Shao, Hongyi; Zhou, Yixin; Tang, Hao; Guo, Shengjie

    2017-11-01

    Lateral soft-tissue release can jeopardize the common peroneal nerve (CPN) in total knee arthroplasty for valgus knees. Previous studies reporting safe zones to protect the CPN were based on well-aligned knees. We conducted this study to compare the localization of the CPN in well-aligned knees and in valgus knees. We conducted a consecutive 3-dimensional radiographic study on magnetic resonance images of 58 well-aligned knees and 39 valgus knees. We measured the distance between the CPN and the tibia, as well as the mediolateral, anteroposterior, and angular location of the CPN. We compared the results between well-aligned knees and valgus knees. We found that there is an increased distance between the CPN and the tibia at the level of the tibial cut, but not at the joint line in valgus knees. It is safer to release the posterolateral capsule at the tibial side than at the level above this. The angular location and the mediolateral or anteroposterior location of the CPN in valgus knees are similar to those of well-aligned knees. The location of the CPN in valgus knees is similar to that in well-aligned knees. The previously reported safe zone in well-aligned knees is applicable in valgus knees to protect the CPN. Copyright © 2017 Elsevier Inc. All rights reserved.

  5. Managing Recurrence in Intraarticular Melorheostosis Involving the Knee Joint: A Case Report.

    PubMed

    John, Bobby; Sharma, Anirudh; Pandey, Ritesh A

    2017-01-01

    Melorheostosis is a rare benign sclerosing dysplasia affecting bone, which causes significant morbidity in the form of pain and restriction of joint movement. Treatment options are varied, and recurrence is common after surgical treatment. Choosing the most appropriate treatment option in the management of a recurrent case is challenging, with very little supporting evidence in literature owing to the rarity of the disease. We hereby present a case of recurrent melorheostosis involving the knee; discuss treatment options and the rationale of our treatment. We present the case of a 42-year-old female who was operated at our institution previously 7 years ago for melorheostosis of her left knee and had undergone excision of intrarticular hyperostotic masses. However, pain and limitation of motion recurred in the operated knee 4 years later, and radiographs and computed tomography revealed a mineralized mass situated behind the patella in the patellofemoral joint. She was treated with repeat open excision of the mass and put on a regimen of physiotherapy and bisphosphonates. Open excision of symptomatic hyperostotic or mineralized soft tissue masses is perhaps the favored treatment option in such cases, the other options being arthroscopic excision and total knee arthroplasty. Limited knee motion and size of the mass often make arthroscopy an unfeasible option. Total knee arthroplasty should be reserved for cases with significant flexion contractures of the knee, or where multiple excisions have failed.

  6. Knee Joint Loads and Surrounding Muscle Forces during Stair Ascent in Patients with Total Knee Replacement

    PubMed Central

    Rasnick, Robert; Standifird, Tyler; Reinbolt, Jeffrey A.; Cates, Harold E.

    2016-01-01

    Total knee replacement (TKR) is commonly used to correct end-stage knee osteoarthritis. Unfortunately, difficulty with stair climbing often persists and prolongs the challenges of TKR patents. Complete understanding of loading at the knee is of great interest in order to aid patient populations, implant manufacturers, rehabilitation, and future healthcare research. Musculoskeletal modeling and simulation approximates joint loading and corresponding muscle forces during a movement. The purpose of this study was to determine if knee joint loadings following TKR are recovered to the level of healthy individuals, and determine the differences in muscle forces causing those loadings. Data from five healthy and five TKR patients were selected for musculoskeletal simulation. Variables of interest included knee joint reaction forces (JRF) and the corresponding muscle forces. A paired samples t-test was used to detect differences between groups for each variable of interest (p<0.05). No differences were observed for peak joint compressive forces between groups. Some muscle force compensatory strategies appear to be present in both the loading and push-off phases. Evidence from knee extension moment and muscle forces during the loading response phase indicates the presence of deficits in TKR in quadriceps muscle force production during stair ascent. This result combined with greater flexor muscle forces resulted in similar compressive JRF during loading response between groups. PMID:27258086

  7. What Is the Efficacy of Repeat Manipulations Under Anesthesia to Treat Stiffness Following Primary Total Knee Arthroplasty?

    PubMed

    Issa, Kimona; Pierce, Todd P; Brothers, Alexander; McInerney, Vincent K; Chughtai, Morad; Mistry, Jaydev B; Bryant, Wayne W; Delanois, Ronald E; Harwin, Steven F; Mont, Michael A

    2016-04-01

    Manipulation under anesthesia (MUA) can help post-total knee arthroplasty (TKA) patients who have knee stiffness regain range-of-motion. However, despite undergoing MUA, patients may have persistent knee stiffness. Often, this persistent knee stiffness is treated with a repeat MUA. Therefore, the purpose of this study was to evaluate repeat MUAs by assessing: (1) demographic characteristics, (2) range-of-motion, (3) clinical outcomes, and (4) rate of revision surgery in post-TKA patients with persistent knee stiffness who either underwent a single MUA or repeat MUAs. One-hundred-and-sixty-seven post-TKA who had undergone an MUA between 2005 and 2011 at two institutions were reviewed. Patients were stratified into those who had a single-MUA (138 knees) and those who had a repeat MUA (29 knees). The mean follow-up period was 63 months (range, 36 to 90 months). The incidence of repeat MUA within this cohort was determined. Demographics and ROM were compared using Student t-test and Chi-square as appropriate. Functional outcomes were assessed using Knee Society scores (KSS) and compared between the two cohorts. Among the 167 patients who underwent a MUA, 29 (17%) required repeat manipulations. The repeat MUA cohort was younger and more likely to have osteonecrosis as the underlying cause of knee disease. For the repeat MUA cohort, 17 patients (59%) had achieved satisfactory mean gains in ROM after their repeat MUAs. These patients had also achieved excellent mean Knee Society objective and functional scores. However, another seven knees (24%) had further persistent knee stiffness requiring arthrolysis of adhesions and five patients (17%) had undergone revision of the polyethylene spacer or patellar component to improve range-of-motion. In this study, the majority of patients who had undergone a repeat MUA were able to achieve improvements in flexion range-of-motion and functional outcomes. However, the remaining patients required more invasive procedure to treat persistent knee stiffness. In patients who have persistent knee stiffness after MUAs, a repeat MUA may be helpful to increase range-of-motion and function.

  8. Similar early migration when comparing CR and PS in Triathlon™ TKA: A prospective randomised RSA trial.

    PubMed

    Molt, Mats; Toksvig-Larsen, Sören

    2014-10-01

    The objective of this study was to compare the early migration of the cruciate retaining and posterior stabilising versions of the recently introduced Triathlon™ total knee system, with a view to predicting long term fixation performance. Sixty patients were prospectively randomised to receive either Triathlon™ posterior stabilised cemented knee prosthesis or Triathlon™ cruciate retaining cemented knee prosthesis. Tibial component migration was measured by radiostereometric analysis postoperatively and at three months, one year and two years. Clinical outcome was measured by the American Knee Society Score and Knee Osteoarthritis and Injury Outcome Score. There were no differences in rotation around the three coordinal axes or in the maximum total point motion (MTPM) during the two year follow-up. The posterior stabilised prosthesis had more posterior-anterior translation at three months and one year and more caudal-cranial translation at one year and two years. There were no differences in functional outcome between the groups. The tibial tray of the Triathlon™ cemented knee prosthesis showed similar early stability. Level I. Article focus: This was a prospective randomised trial aiming to compare the single radius posterior stabilised (PS) Triathlon™ total knee arthroplasty (TKA) to the cruciate retaining Triathlon™ TKA system with regard to fixation. Strengths and limitations of this study: Strength of this study was that it is a randomised prospective trial using an objective measuring tool. The sample size of 25-30 patients was reportedly sufficient for the screening of implants using RSA [1]. ClinicalTrials.gov Identifier: NCT00436982. Copyright © 2014 Elsevier B.V. All rights reserved.

  9. Preoperative anaemia is associated with increased allogeneic pack red cell transfusion in revision hip and knee joint arthroplasty: a retrospective analysis of 5387 patients over a 10-year period at a single high volume centre.

    PubMed

    Kasivisvanathan, R; Ramesh, V; Rao Baikady, R; Nadaraja, S

    2016-08-01

    To estimate the prevalence of preoperative World Health Organization (WHO) defined anaemia in patients presenting for revision hip and knee arthroplasty and its association with transfusion of allogeneic packed red blood cells (PRBC). Studies have mainly investigated the prevalence of preoperative anaemia in primary and not revision hip and knee joint arthroplasty. An analysis of a prospectively collected patient data for 5387 patients having revision hip or knee arthroplasty over a 10-year period at a single high volume centre was conducted. Logistic regression was used to assess whether the presence of WHO defined preoperative anaemia as well as other risk factors were associated with inpatient allogeneic PRBC transfusion. There were 5387 patients assessed of which 3021 (56·01%) patients had revision total hip replacements and 2366 (43·09%) had revision total knee arthroplasty. Of these patients 1956 (36·03%) had preoperative WHO defined anaemia. A total of 2034 (37·08%) patients received at least one unit of allogeneic PRBC during their primary hospital admission. In the final model preoperative WHO defined anaemia was independently associated with allogeneic PRBC transfusion in hip and knee revision surgery OR 4·042 (4·012-4·072 95% CI) CONCLUSIONS: Preoperative anaemia is common in patients presenting for revision hip and knee arthroplasty and independently associated with transfusion of allogeneic PRBC. © 2016 British Blood Transfusion Society.

  10. [The effect of arthroscopic debridement and conservative treatment in knee osteoarthritis: Results of a 5-year follow-up and literature review].

    PubMed

    Spahn, G; Klinger, H M; Hofmann, G O

    2013-12-01

    This study is aimed to compare the effects of arthroscopic joint debridement over a 5-year period in a clearly defined patient population (only grade III knee osteoarthritis, history < 2 years). A total of 96 patients (50 male and 46 female) underwent arthroscopic knee debridement for knee OA. The main criteria for inclusion were osteoarthritis grade III (Kellgren-Lawrence score) and a maximal history of 2 years. The subjective complaints and the knee-related quality of life were estimated by the KOOS (knee injury and osteoarthritis outcome score). The score increased significantly within the 1 to 3 rd year post operation. After this interval the mean points of the score declined. But after 5 years the KOOS was higher in comparison to the baseline dates. Patients who had undergone conservative treatment at baseline had a significantly different KOOS than patients in the arthroscopy group. Over time, patients in the arthroscopy group had fewer complaints than patients in the conservative treatment group. In both groups, the results decreased over time. A total of 17 patients (17.2 %) needed a conversion to total endoprothetic replacement. The mean time-interval between index operation and conversion was 56.6 (95 % CI 54.4 - 58.4) months. In middle stages of knee OA, arthroscopic joint debridement can effectively reduce subjective complaints. Because this treatment does not stop the process of OA, the improvements decrease over time. © Georg Thieme Verlag KG Stuttgart · New York.

  11. Mortality After Total Knee and Total Hip Arthroplasty in a Large Integrated Health Care System.

    PubMed

    Inacio, Maria C S; Dillon, Mark T; Miric, Alex; Navarro, Ronald A; Paxton, Elizabeth W

    2017-01-01

    The number of excess deaths associated with elective total joint arthroplasty in the US is not well understood. To evaluate one-year postoperative mortality among patients with elective primary and revision arthroplasty procedures of the hip and knee. A retrospective analysis was conducted of hip and knee arthroplasties performed in 2010. Procedure type, procedure volume, patient age and sex, and mortality were obtained from an institutional total joint replacement registry. An integrated health care system population was the sampling frame for the study subjects and was the reference group for the study. Standardized 1-year mortality ratios (SMRs) and 95% confidence intervals (CIs) were calculated. A total of 10,163 primary total knee arthroplasties (TKAs), 4963 primary total hip arthroplasties (THAs), 606 revision TKAs, and 496 revision THAs were evaluated. Patients undergoing primary THA (SMR = 0.6, 95% CI = 0.4-0.7) and TKA (SMR = 0.4, 95% CI = 0.3-0.5) had lower odds of mortality than expected. Patients with revision TKA had higher-than-expected mortality odds (SMR = 1.8, 95% CI = 1.1-2.5), whereas patients with revision THA (SMR = 0.9, 95% CI = 0.4-1.5) did not have higher-than-expected odds of mortality. Understanding excess mortality after joint surgery allows clinicians to evaluate current practices and to determine whether certain groups are at higher-than-expected mortality risk after surgery.

  12. The female knee: anatomic variations.

    PubMed

    Conley, Sheryl; Rosenberg, Aaron; Crowninshield, Roy

    2007-01-01

    Traditional knee implants have been designed "down the middle,"based on the combined average size and shape of male and female knee anatomy.Sex-based research in the field of orthopaedics has led to new understanding of the anatomic differences between the sexes and the associated implications for women undergoing total knee arthroplasty. Through the use of a comprehensive bone morphology atlas that utilizes novel three-dimensional computed tomography analysis technology, significant anatomic differences have been documented in the shape and size of female knees compared with male knees. This research identifies three notable anatomic differences in the female population: a less prominent anterior condyle, an increased Q angle, and a reduced medial-lateral:anterior-posterior aspect ratio.

  13. Efficacy and Safety of a Novel Three-Step Medial Release Technique in Varus Total Knee Arthroplasty.

    PubMed

    Kim, Min Woo; Koh, In Jun; Kim, Ju Hwan; Jung, Jae Jong; In, Yong

    2015-09-01

    We investigated the efficacy and safety of our novel three-step medial release technique in varus total knee arthroplasty (TKA) over time. Two hundred sixty seven consecutive varus TKAs were performed by applying the algorithmic release technique which consisted of sequential release of the deep medial collateral ligament (step 1), the semimembranosus (step 2), and multiple needle puncturing of the superficial medial collateral ligament (step 3). One hundred seventeen, 114, and 36 knees were balanced after step 1, 2, and 3 releases, respectively. There were no significant differences in changes of medial and lateral laxities between groups in over a year. Our novel stepwise medial release technique was efficacious and safe in balancing varus knees during TKA. Copyright © 2015 Elsevier Inc. All rights reserved.

  14. Limb salvage after infected knee arthroplasty with bone loss and extensor mechanism deficiency using a modular segmental replacement system.

    PubMed

    Namdari, Surena; Milby, Andrew H; Garino, Jonathan P

    2011-09-01

    Multiple total knee arthroplasty revisions pose significant surgical challenges, such as bone loss and soft tissue compromise. For patients with bone loss and extensor mechanism insufficiency after total knee arthroplasty, arthrodesis is a treatment option for the avoidance of amputation. However, arthrodesis is both difficult to achieve in situations with massive bone loss and potentially undesirable due to the dramatic shortening that follows. Although intramedullary nailing for knee arthrodesis has been widely reported, this technique has traditionally relied on the achievement of bony union. We report a case of a patient with massive segmental bone loss in which a modular intercalary prosthesis was used for arthrodesis to preserve limb length without bony union. Copyright © 2011 Elsevier Inc. All rights reserved.

  15. Knee degeneration in concrete reinforcement workers.

    PubMed Central

    Wickström, G; Hänninen, K; Mattsson, T; Niskanen, T; Riihimäki, H; Waris, P; Zitting, A

    1983-01-01

    The loads on the knees in concrete reinforcement work and maintenance painting were analysed on eight construction work sites. A total of 352 reinforcement workers and 231 painters. Finnish men aged 20-64, were clinically and radiologically examined to determine the condition of the knee joints in active workers. The loads on the knees and the occurrence of minor injuries and accidents were higher in reinforcement work than in painting, but the occurrence of symptoms, clinical signs, and radiological findings was equally common in both groups. Reinforcement work seemed to provoke more symptoms from degenerated knees than painting. PMID:6830721

  16. Analysis of Impingement between Patella Bone and Bearing Post in Cruciate-Substituting High-Flexion Total Knee Arthroplasty

    PubMed Central

    Chon, Jegyun; Shin, Sangyeop; Jang, Gunil; Jeon, Taehyeon

    2016-01-01

    Background We investigated the causes of impingement between the patella bone and the bearing post during high flexion in cruciate-substituting total knee arthroplasty and proposed a treatment strategy. Methods This prospective cohort study included 218 cases that had undergone cruciate-substituting total knee arthroplasty from February 2014 to January 2015; a single surgeon performed the operation using the same method without patellar resurfacing in all patients. Results In these patients, the occurrence of impingement was determined by performing more than 120° high knee flexion after inserting a bearing perioperatively. The incidence of impingement was significantly associated with bearing design, femoral implant size, patella bone length, and patella inferior pole angle (p < 0.05). The impingement was resolved by resection of the lower articular side of the patella bone. Conclusions In the cruciate-substituting high-flexion total knee arthroplasty, impingement between the patella bone and bearing post was more common in patients with mobile bearing, small-size femoral component, and a long patella or a large inferior pole angle. In cases of intraoperative impingement between the patella bone and the bearing post, resection in the lower portion of the patella prevented impingement of the bearing with soft tissue or the patella by widening the space between the patella and the bearing post, which in turn prevented postoperative reduction in range of motion. PMID:27247740

  17. The high prevalence of pathologic calcium crystals in pre-operative knees.

    PubMed

    Derfus, Beth A; Kurian, Jason B; Butler, Jeffrey J; Daft, Laureen J; Carrera, Guillermo F; Ryan, Lawrence M; Rosenthal, Ann K

    2002-03-01

    Calcium pyrophosphate dihydrate (CPPD) and basic calcium phosphate (BCP) crystals are important in the pathogenesis of osteoarthritis (OA) but are under recognized even in end stage disease. We determined the prevalence of these calcium crystals in synovial fluid (SF) of persons undergoing total knee arthroplasty for degenerative arthritis. SF samples were obtained from 53 knee joints undergoing total arthroplasty for a pre-operative diagnosis of OA. SF were analyzed via compensated light microscopy for CPPD crystals and a semiquantitative radiometric assay for BCP crystals. Fifty pre-operative radiographs were analyzed and graded according to the scale of Kellgren and Lawrence. Patients had an average age of 70 years at the time of surgery. CPPD and/or BCP crystals were identified in 60% of SF. Overall radiographic scores correlated with mean concentrations of BCP crystals. Higher mean radiographic scores correlated with the presence of calcium-containing crystals of either type in SF Radiographic chondrocalcinosis was identified in only 31% of those with SF CPPD. Pathologic calcium crystals were present in a majority of SF at the time of total knee arthroplasty. Intraoperative SF analysis could conveniently identify pathologic calcium crystals providing information that may be relevant to the future care of the patient's replaced joint and that of other joints. This information could also potentially aid in predicting the likelihood of the need for contralateral total knee arthroplasty.

  18. Analysis of Impingement between Patella Bone and Bearing Post in Cruciate-Substituting High-Flexion Total Knee Arthroplasty.

    PubMed

    Chon, Jegyun; Lee, Bongju; Shin, Sangyeop; Jang, Gunil; Jeon, Taehyeon

    2016-06-01

    We investigated the causes of impingement between the patella bone and the bearing post during high flexion in cruciate-substituting total knee arthroplasty and proposed a treatment strategy. This prospective cohort study included 218 cases that had undergone cruciate-substituting total knee arthroplasty from February 2014 to January 2015; a single surgeon performed the operation using the same method without patellar resurfacing in all patients. In these patients, the occurrence of impingement was determined by performing more than 120° high knee flexion after inserting a bearing perioperatively. The incidence of impingement was significantly associated with bearing design, femoral implant size, patella bone length, and patella inferior pole angle (p < 0.05). The impingement was resolved by resection of the lower articular side of the patella bone. In the cruciate-substituting high-flexion total knee arthroplasty, impingement between the patella bone and bearing post was more common in patients with mobile bearing, small-size femoral component, and a long patella or a large inferior pole angle. In cases of intraoperative impingement between the patella bone and the bearing post, resection in the lower portion of the patella prevented impingement of the bearing with soft tissue or the patella by widening the space between the patella and the bearing post, which in turn prevented postoperative reduction in range of motion.

  19. Plateau-patella angle in evaluation of patellar height after total knee arthroplasty.

    PubMed

    Robin, Brett N; Ellington, Matthew D; Jupiter, Daniel C; Allen, Bryce C

    2014-07-01

    The plateau-patella angle (PPA) has been proposed as a new and simpler method to describe patellar height. This method has not been used or validated in knees following total knee arthroplasty (TKA). A modified PPA (mPPA) was developed for use in this population. The method was validated by determining the interobserver and intraobserver reliability of the technique in 50 consecutive patients compared to three well-described methods of describing patellar height after TKA. Three observers then evaluated the mPPA of 297 post-operative radiographs to describe a normal range after TKA for a given technique and implant. The interobserver reliability was the highest for the mPPA compared to the other methods. The mean mPPA for the entire cohort was 21.06, 20.49, and 19.94 for the three observers. The modified plateau-patella angle is a reliable way to evaluate patellar height in patients who have undergone total knee arthroplasty. Copyright © 2014 Elsevier Inc. All rights reserved.

  20. Radiographic and scintigraphic evaluation of total knee arthroplasty

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schneider, R.; Soudry, M.

    1986-04-01

    Various radiographic and scintigraphic methods are used to supplement clinical findings in the evaluation of total knee arthroplasty and its complications. Serial roentgenograms offer reliable information for diagnosing mechanical loosening. Wide and extensive radiolucency at the cement-bone interface and shift in position and alignment of prosthetic components can be seen in almost all cases by the time revision is necessary. Radiographic abnormalities are usually not present in acute infection, but are often present in chronic infection. Bone scanning has a high sensitivity for diagnosis of infection or loosening, but is nonspecific because increased uptake is often present around asymptomatic totalmore » knee arthroplasties with normal radiographs. Differential bone and Gallium scanning and scanning with Indium 111-labeled leukocytes have a greater specificity for diagnosis of infection than does bone or Gallium scanning alone. Routine radiographic and scintigraphic studies have shown a high incidence of deep vein thrombosis in the calf after total knee arthroplasty. Clinically significant pulmonary embolization is infrequent.« less

  1. Patient-specific positioning guides versus manual instrumentation for total knee arthroplasty: an intraoperative comparison.

    PubMed

    Kassab, Safa; Pietrzak, William S

    2014-01-01

    Traditional manual instruments for total knee arthroplasty are associated with a malalignment rate of nearly 30%. Patient-specific positioning guides, developed to help address alignment, may also influence other intraoperative factors. This study compared a consecutive series of 270 Vanguard total knee replacements performed with Signature patient-specific positioning guides (study group) to a consecutive series of 595 similar knee replacements performed with manual instrumentation (control group). The study group averaged 16.7 fewer minutes in the operating room (p < .001), utilized tibial inserts that averaged 0.4 mm thinner with a smaller proportion of "thick" tibial inserts (14-18 mm) (p < .001), and required fewer transfusions (p = .022). The Signature-derived surgical plan accurately predicted correct femoral and tibial component sizes in 86.3% and 70.3% of the cases, respectively. These rates increased to 99.3% and 99.2%, respectively, for accuracy to within one size of the surgical plan, similar to published values for manual instrumentation.

  2. Comparative Effectiveness Review of Cooled Versus Pulsed Radiofrequency Ablation for the Treatment of Knee Osteoarthritis: A Systematic Review.

    PubMed

    Gupta, Anita; Huettner, Daniel P; Dukewich, Matthew

    2017-03-01

    Patients suffering from osteoarthritis of the knee and patients post total knee arthroplasty often develop refractory, disabling chronic knee pain. Radiofrequency ablation, including conventional, pulsed, and cooled, has recently become more accepted as an interventional technique to manage chronic knee pain in patients who have failed conservative treatment or who are not suitable candidates for surgical treatment. This systematic review aimed to analyze published studies on radiofrequency ablation to provide an overview of the current knowledge regarding variations in procedures, nerve targets, adverse events, and temporal extent of clinical benefit. A systematic review of published studies investigating conventional, pulsed, or cooled radiofrequency ablation in the setting of chronic knee pain. Medline, Google Scholar, and the Cochrane Central Register of Controlled Trials (CENTRAL) databases were reviewed for studies on radiofrequency ablation for patients with chronic knee pain through July 29, 2016. From the studies, the procedural details, outcomes after treatment, follow-up points, and complications were compiled and analyzed in this literature review. Included studies were analyzed for clinical relevance and strength of evidence was graded using either the NHLBI Quality assessment of controlled intervention studies or the NHLBI quality assessment for before-after (pre-post) studies with no control group. Seventeen total publications were identified in the search, including articles investigating conventional, pulsed, or cooled radiofrequency ablation. These studies primarily targeted either the genicular nerves or used an intraarticular approach. Of the studies, 5 were small-sized randomized controlled trials, although one involved diathermy radiofrequency ablation. There were 8 retrospective or prospective case series and 4 case reports. Utilizing the strength of evidence grading, there is a low level of certainty to suggest a superior benefit between targeting the genicular nerve, an intraarticular approach, or targeting the larger nerves such as femoral and tibial nerves. Utilizing the strength of evidence grading, there is a low level of certainty in supporting the superiority of any specific RFA procedure modality. The majority of the studies report positive patient outcomes, but the inconsistent procedural methodology, inconsistent patient assessment measures, and small study sizes limit the applicability of any specific study to clinical practice. While the wide search strategy included a variety of articles, broad conclusions and pooled data could not be obtained based on the studies analyzed. Overall, the studies showed promising results for the treatment of severe chronic knee pain by radiofrequency ablation at up to one year with minimal complications. Numerous studies, however, yielded concerns about procedural protocols, study quality, and patient follow-up. Radiofrequency ablation can offer substantial clinical and functional benefit to patients with chronic knee pain due to osteoarthritis or post total knee arthroplasty.Key words: Radiofrequency ablation, knee osteoarthritis, knee pain, genicular nerve, total knee arthroplasty (TKA), cooled radiofrequency ablation, pulsed radiofrequency ablation.

  3. Stability of knee ligament complex of Thiel-embalmed cadaver compared to in vivo knee.

    PubMed

    Völlner, Florian; Pilsl, Ulrike; Craiovan, Benjamin; Zeman, Florian; Schneider, Michael; Wörner, Michael; Grifka, Joachim; Weber, Markus

    2017-07-01

    The first biomechanical evaluation of new implants is usually carried out with cadavers. Fixation of Thiel-embalmed cadavers is supposed to preserve the histological structure, colour and consistency of the tissue and has a low risk of infection and toxicity. However, the biomechanical properties of Thiel-fixated tissue are still unknown. The aim of this study was to quantify the effect of the Thiel-embalming method on the elastic properties of the ligament complex of the knee compared to in vivo knees during total knee arthroplasty. The results of biomechanical tensile tests with 10 Thiel-embalmed knees were compared with the findings of 10 patients who underwent total knee arthroplasty with a standardised knee balancer at our department. We reconstructed the force-elongation curves of the medial and lateral ligament complex and calculated the stiffness in direct correlation with overall soft tissue stability in full extension and in 90° of flexion. All curves consisted of a non-linear part at the beginning and a linear part from about 80N onwards. In full extension, median stiffness in the cadavers was 26.6N/mm for the medial compartment and 31.6N/mm for the lateral compartment. The values for in vivo were 25.7N/mm for the medial compartment and 25.3N/mm for the lateral compartment (p=0.684 for the medial compartment and p=0.247 for the lateral compartment). In 90° of flexion, median stiffness in the cadaver group was 24.7N/mm for the medial compartment and 22.2N/mm for the lateral compartment. In vivo, median stiffness was 30.3N/mm for the medial compartment and 29.2N/mm for the lateral compartment (p=0.009 for the medial compartment and p=0.143 for the lateral compartment). Stiffness of the medial and lateral ligament complex in the knee was comparable between Thiel-embalmed cadavers and in vivo patients during total knee arthroplasty. Thiel fixation seems to preserve the soft tissue properties similar to those in vivo. Copyright © 2017 Elsevier Ltd. All rights reserved.

  4. Short-term outcome of 1,465 computer-navigated primary total knee replacements 2005–2008

    PubMed Central

    2011-01-01

    Background and purpose Improvement of positioning and alignment by the use of computer-assisted surgery (CAS) might improve longevity and function in total knee replacements, but there is little evidence. In this study, we evaluated the short-term results of computer-navigated knee replacements based on data from the Norwegian Arthroplasty Register. Patients and methods Primary total knee replacements without patella resurfacing, reported to the Norwegian Arthroplasty Register during the years 2005–2008, were evaluated. The 5 most common implants and the 3 most common navigation systems were selected. Cemented, uncemented, and hybrid knees were included. With the risk of revision for any cause as the primary endpoint and intraoperative complications and operating time as secondary outcomes, 1,465 computer-navigated knee replacements (CAS) and 8,214 conventionally operated knee replacements (CON) were compared. Kaplan-Meier survival analysis and Cox regression analysis with adjustment for age, sex, prosthesis brand, fixation method, previous knee surgery, preoperative diagnosis, and ASA category were used. Results Kaplan-Meier estimated survival at 2 years was 98% (95% CI: 97.5–98.3) in the CON group and 96% (95% CI: 95.0–97.8) in the CAS group. The adjusted Cox regression analysis showed a higher risk of revision in the CAS group (RR = 1.7, 95% CI: 1.1–2.5; p = 0.02). The LCS Complete knee had a higher risk of revision with CAS than with CON (RR = 2.1, 95% CI: 1.3–3.4; p = 0.004)). The differences were not statistically significant for the other prosthesis brands. Mean operating time was 15 min longer in the CAS group. Interpretation With the introduction of computer-navigated knee replacement surgery in Norway, the short-term risk of revision has increased for computer-navigated replacement with the LCS Complete. The mechanisms of failure of these implantations should be explored in greater depth, and in this study we have not been able to draw conclusions regarding causation. PMID:21504309

  5. [Surgical technique and clinical results of total knee arthroplasty in treating endstage gonarthrosis combined with valgus knee deformity].

    PubMed

    Wang, Xingshan; Weng, Xisheng; Lin, Jin; Jin, Jin; Qian, Wenwei

    2012-05-01

    To investigate the surgical technique and the clinical results of total knee arthroplasty (TKA) in treating end-stage gonarthrosis combined with valgus knee deformity. Between November 1998 and October 2010, 64 patients (72 knees) with end-stage gonarthrosis combined with valgus knee deformity underwent TKA by a medial parapatellar approach. Of the 64 patients, 18 were male and 46 were female with an average age of 62.5 years (range, 23-82 years), including 44 cases (49 knees) of osteoarthritis, 17 cases (20 knees) of rheumatoid arthritis, 2 cases (2 knees) of haemophilic arthritis, and 1 case (1 knee) of post-traumatic arthritis. Bilateral knees were involved in 8 cases, and single knee in 56 cases. The flexion and extension range of motion (ROM) of the knee joint was (82.2 +/- 28.7) degrees; the femur-tibia angle (FTA) was (18.0 +/- 5.8) degrees; according to Knee Society Score (KSS) criterion, the preoperative clinical score was 31.2 +/- 10.1 and functional score was 37.3 +/- 9.0. According to Krackow's classification, there were 65 knees of type I and 7 knees of type II. By medial parapatellar approach, conventional osteotomy and Ranawat soft tissue release were performed in all cases. Prosthesis of preserved posterior cruciate ligament were used in 7 cases (7 knees), posterior stabilize prosthesis in 54 cases (60 knees), constrained prosthesis in 4 cases (5 knees). Incisions healed by first intention in all cases. Peroneal nerve palsy occurred in 1 patient with haemophilic arthritis, severe valgus deformity (FTA was 41 degrees), and flexion contracture (20 degrees), which was cured after 1 year of conservative treatment. Revison surgery was performed in 1 case of deep infection at 2 years after surgery. All the patients were followed up 4.9 years on average (range, 1-13 years). At last follow-up, the FTA was (7.0 +/- 2.5) degrees, showing significant difference when compared with preoperative value (t = 15.502, P = 0.000). The KSS clinical score was 83.0 +/- 6.6 and functional score was 85.1 +/- 10.5, the flexion and extension ROM of the knee joint was (106.1 +/- 17.0) degrees, all showing significant differences when compared with preoperative values (P < 0.05). Five patients had 12-15 degrees valgus knee deformity, but the function of the affect knees were good. TKA is an effective way for the patients with end-stage gonarthrosis combined with valgus knee deformity by medial parapatellar approach combined with conventional osteotomy and Ranawat soft tissue release. The correction of deformity and improvement of joint function can be achieved significantly. The clinical result is satisfactory.

  6. Impact of the economic downturn on total joint replacement demand in the United States: updated projections to 2021.

    PubMed

    Kurtz, Steven M; Ong, Kevin L; Lau, Edmund; Bozic, Kevin J

    2014-04-16

    Few studies have explored the role of the National Health Expenditure and macroeconomics on the utilization of total joint replacement. The economic downturn has raised questions about the sustainability of growth for total joint replacement in the future. Previous projections of total joint replacement demand in the United States were based on data up to 2003 using a statistical methodology that neglected macroeconomic factors, such as the National Health Expenditure. Data from the Nationwide Inpatient Sample (1993 to 2010) were used with United States Census and National Health Expenditure data to quantify historical trends in total joint replacement rates, including the two economic downturns in the 2000s. Primary and revision hip and knee arthroplasty were identified using codes from the International Classification of Diseases, Ninth Revision, Clinical Modification. Projections in total joint replacement were estimated using a regression model incorporating the growth in population and rate of arthroplasties from 1993 to 2010 as a function of age, sex, race, and census region using the National Health Expenditure as the independent variable. The regression model was used in conjunction with government projections of National Health Expenditure from 2011 to 2021 to estimate future arthroplasty rates in subpopulations of the United States and to derive national estimates. The growth trend for the incidence of joint arthroplasty, for the overall United States population as well as for the United States workforce, was insensitive to economic downturns. From 2009 to 2010, the total number of procedures increased by 6.0% for primary total hip arthroplasty, 6.1% for primary total knee arthroplasty, 10.8% for revision total hip arthroplasty, and 13.5% for revision total knee arthroplasty. The National Health Expenditure model projections for primary hip replacement in 2020 were higher than a previously projected model, whereas the current model estimates for total knee arthroplasty were lower. Economic downturns in the 2000s did not substantially influence the national growth trends for hip and knee arthroplasty in the United States. These latest updated projections provide a basis for surgeons, hospitals, payers, and policy makers to plan for the future demand for total joint replacement surgery.

  7. Fixed or mobile-bearing total knee arthroplasty

    PubMed Central

    Huang, Chun-Hsiung; Liau, Jiann-Jong; Cheng, Cheng-Kung

    2007-01-01

    Fixed and mobile-bearing in total knee arthroplasty are still discussed controversially. In this article, biomechanical and clinical aspects in both fixed and mobile-bearing designs were reviewed. In biomechanical aspect, the mobile-bearing design has proved to provide less tibiofemoral contact stresses under tibiofemoral malalignment conditions. It also provides less wear rate in in-vitro simulator test. Patients with posterior stabilized mobile-bearing knees had more axial tibiofemoral rotation than patients with posterior stabilized fixed-bearing knees during gait as well as in a deep knee-bend activity. However, in clinical aspect, the mid-term or long-term survivorship of mobile-bearing knees has no superiority over that of fixed-bearing knees. The theoretical advantages for mobile-bearing design to provide a long-term durability have not been demonstrated by any outcome studies. Finally, the fixed-bearing design with all-polyethylene tibial component is suggested for relatively inactive, elder people. The mobile-bearing design is suggested for younger or higher-demand patients due to the potential for reduced polyethylene wear and more normal kinematics response after joint replacement. For younger surgeon, the fixed-bearing design is suggested due to less demand for surgical technique. For experienced surgeon, one familiar surgical protocol and instrumentation is suggested rather than implant design, either fixed-bearing or mobile-bearing. PMID:17204165

  8. Differences in knee joint kinematics and forces after posterior cruciate retaining and stabilized total knee arthroplasty.

    PubMed

    Wünschel, Markus; Leasure, Jeremi M; Dalheimer, Philipp; Kraft, Nicole; Wülker, Nikolaus; Müller, Otto

    2013-12-01

    Posterior cruciate ligament (PCL) retaining (CR) and -sacrificing (PS) total knee arthroplasties (TKA) are widely-used to treat osteoarthritis of the knee joint. The PS design substitutes the function of the PCL with a cam-spine mechanism which may produce adverse changes to joint kinematics and kinetics. CR- and PS-TKA were performed on 11 human knee specimens. Joint kinematics were measured with a dynamic knee simulator and motion tracking equipment. In-situ loads of the PCL and cam-spine were measured with a robotic force sensor system. Partial weight bearing flexions were simulated and external forces were applied. The PS-TKA rotated significantly less throughout the whole flexion range compared to the CR-TKA. Femoral roll back was greater in the PS-TKA; however, this was not correlated with lower quadriceps forces. Application of external loads produced significantly different in-situ force profiles between the TKA systems. Our data demonstrate that the PS-design significantly alters kinematics of the knee joint. Our data also suggest the cam-spine mechanism may have little influence on high flexion kinematics (such as femoral rollback) with most of the load burden shared by supporting implant and soft-tissue structures. Copyright © 2013 Elsevier B.V. All rights reserved.

  9. Fixed or mobile-bearing total knee arthroplasty.

    PubMed

    Huang, Chun-Hsiung; Liau, Jiann-Jong; Cheng, Cheng-Kung

    2007-01-05

    Fixed and mobile-bearing in total knee arthroplasty are still discussed controversially. In this article, biomechanical and clinical aspects in both fixed and mobile-bearing designs were reviewed. In biomechanical aspect, the mobile-bearing design has proved to provide less tibiofemoral contact stresses under tibiofemoral malalignment conditions. It also provides less wear rate in in-vitro simulator test. Patients with posterior stabilized mobile-bearing knees had more axial tibiofemoral rotation than patients with posterior stabilized fixed-bearing knees during gait as well as in a deep knee-bend activity. However, in clinical aspect, the mid-term or long-term survivorship of mobile-bearing knees has no superiority over that of fixed-bearing knees. The theoretical advantages for mobile-bearing design to provide a long-term durability have not been demonstrated by any outcome studies. Finally, the fixed-bearing design with all-polyethylene tibial component is suggested for relatively inactive, elder people. The mobile-bearing design is suggested for younger or higher-demand patients due to the potential for reduced polyethylene wear and more normal kinematics response after joint replacement. For younger surgeon, the fixed-bearing design is suggested due to less demand for surgical technique. For experienced surgeon, one familiar surgical protocol and instrumentation is suggested rather than implant design, either fixed-bearing or mobile-bearing.

  10. Lower extremity kinematics and kinetics of Division III collegiate baseball and softball players while performing a modified pro-agility task.

    PubMed

    Wallace, B J; Kernozek, T W; Bothwell, E C

    2007-12-01

    Females experience at least twice as many non-contact anterior cruciate ligament (ACL) injuries as males. The aim of this study was to investigate if males and females exhibited different characteristics while performing a modified pro-agility test. Collegiate Division III male baseball (n=14) and female softball (n=13) players performed 4 trials of a modified pro-agility task, which consisted of running toward a force platform target for 5 steps, planting their right foot, and propelling themselves off of the target with their left foot. Kinematic and kinetic parameters were compared using a multivariate analysis of variance between gender with the level of significance set at P<0.05. Males and females exhibited similar knee valgus angles. Females had a greater maximum knee extension angle (10.14 degrees vs 17.43 degrees ), and greater knee range of motion (46.12 degrees vs 40.12 degrees ). Both groups reached maximum knee flexion at 52% of stance. Females had significantly more maximum hip flexion than males (28.86 degrees vs 22.75 degrees ). Females had significantly smaller minimum internal knee varus moments than their male counterparts (1.12 Nm/kg vs 1.55 Nm/kg). Vertical ground reaction forces as a percentage of bodyweight, and stance time, were not statistically different. The female group displayed an external knee rotation angle (2.49 degrees ) during the beginning of their stance, which was significantly different than the internal rotation angle (4.11 degrees ) in the male group. Early in stance knee rotation angle was highly correlated with the lack of internal knee varus moment (males R(2)=0.75, females R(2)=0.88). Females displayed knee moments and kinematics that may place them at greater risk for ACL injury during a stop-cut task. Females should be coached to perform stop cuts with more knee flexion and a more neutral knee rotation angle upon foot contact in an effort to reduce moments that may place the ACL at risk.

  11. Hemophilia A Pseudoaneurysm in a Patient with High Responding Inhibitors Complicating Total Knee Arthroplasty: Embolization: A Cost-Reducing Alternative to Medical Therapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kickuth, Ralph, E-mail: ralph.kickuth@insel.ch; Anderson, Suzanne; Peter-Salonen, Kristiina

    2006-12-15

    Joint hemorrhages are very common in patients with severe hemophilia. Inhibitors in patients with hemophilia are allo-antibodies that neutralize the activity of the clotting factor. After total knee replacement, rare intra-articular bleeding complications might occur that do not respond to clotting factor replacement. We report a 40-year-old male with severe hemophilia A and high responding inhibitors presenting with recurrent knee joint hemorrhage after bilateral knee prosthetic surgery despite adequate clotting factor treatment. There were two episodes of marked postoperative hemarthrosis requiring extensive use of subsititution therapy. Eleven days postoperatively, there was further hemorrhage into the right knee. Digital subtraction angiographymore » diagnosed a complicating pseudoaneurysm of the inferior lateral geniculate artery and embolization was successfully performed. Because clotting factor replacement therapy has proved to be excessively expensive and prolonged, especially in patients with inhibitors, we recommend the use of cost-effective early angiographic embolization.« less

  12. Predictors of perioperative blood loss in total joint arthroplasty.

    PubMed

    Park, Jai Hyung; Rasouli, Mohammad R; Mortazavi, S M Javad; Tokarski, Anthony T; Maltenfort, Mitchell G; Parvizi, Javad

    2013-10-02

    UPDATE The print version of this article has errors that have been corrected in the online version of this article. In the Materials and Methods section, the sentence that reads as "During the study period, our institution offered preoperative autologous blood donation to all patients who were scheduling for total joint arthroplasty with a hemoglobin level of no less than 11 mg/dL or a hematocrit level of at least 33%." in the print version now reads as "During the study period, our institution offered preoperative autologous blood donation to all patients who were scheduling for total joint arthroplasty with a hemoglobin level of no less than 11 g/dL or a hematocrit level of at least 33%." in the online version. In Table III, the footnote that reads as "The values are given as the estimate and the standard error in milligrams per deciliter." in the print version now reads as "The values are given as the estimate and the standard error in grams per deciliter." in the online version. Despite advances in surgical and anesthetic techniques, lower-extremity total joint arthroplasty is associated with considerable perioperative blood loss. As predictors of perioperative blood loss and allogenic blood transfusion have not yet been well defined, the purpose of this study was to identify clinical predictors for perioperative blood loss and allogenic blood transfusion in patients undergoing total joint arthroplasty. From 2000 to 2008, all patients undergoing unilateral primary total hip or knee arthroplasty who met the inclusion criteria were enrolled in the study. Perioperative blood loss was calculated with use of a previously validated formula. The predictors of perioperative blood loss and allogenic blood transfusion were identified in a multivariate analysis. Eleven thousand three hundred and seventy-three patients who underwent total joint arthroplasty, including 4769 patients who underwent total knee arthroplasty and 6604 patients who underwent total hip arthroplasty, were evaluated. Multivariate analysis indicated that an increase in blood loss was associated with being male (263.59 mL in male patients who had undergone total hip arthroplasty and 233.60 mL in male patients who had undergone total knee arthroplasty), a Charlson Comorbidity Index of >3 (293.99 mL in patients who had undergone total hip arthroplasty and 167.96 mL in patients who had undergone total knee arthroplasty), and preoperative autologous blood donation (593.51 mL in patients who had undergone total hip arthroplasty and 592.30 mL in patients who had undergone total knee arthroplasty). In patients who underwent total hip arthroplasty, regional anesthesia compared with general anesthesia reduced the amount of blood loss. The risk of allogenic blood transfusion increased with the amount of blood loss in the patients who underwent total hip arthroplasty (odds ratio, 1.43 [95% confidence interval, 1.40 to 1.46]) and the patients who underwent total knee arthroplasty (odds ratio, 1.47 [95% confidence interval, 1.42 to 1.51]), but the risk of blood transfusion increased with the Charlson Comorbidity Index only in patients who underwent total knee arthroplasty (odds ratio, 3.2 [95% confidence interval, 1.99 to 5.15]). The risk of allogenic blood transfusion decreased with preoperative autologous blood donation in patients who underwent total hip arthroplasty (odds ratio, 0.01 [95% confidence interval, 0.01 to 0.02]) and patients who underwent total knee arthroplasty (odds ratio, 0.02 [95% confidence interval, 0.01 to 0.03]). This study identified some clinical predictors for blood loss in patients undergoing total joint arthroplasty that we believe can be used for implementing more effective blood conservation strategies. Prognostic Level IV. See Instructions for Authors for a complete description of levels of evidence.

  13. Multiobjective optimization of cartilage stress for non-invasive, patient-specific recommendations of high tibial osteotomy correction angle - a novel method to investigate alignment correction.

    PubMed

    Zheng, Keke; Scholes, Corey J; Chen, Junning; Parker, David; Li, Qing

    2017-04-01

    Medial opening wedge high tibial osteotomy (MOWHTO) is a surgical procedure to treat knee osteoarthritis associated with varus deformity. However, the ideal final alignment of the Hip-Knee-Ankle (HKA) angle in the frontal plane, that maximizes procedural success and post-operative knee function, remains controversial. Therefore, the purpose of this study was to introduce a subject-specific modeling procedure in determining the biomechanical effects of MOWHTO alignment on tibiofemoral cartilage stress distribution. A 3D finite element knee model derived from magnetic resonance imaging of a healthy participant was manipulated in-silico to simulate a range of final HKA angles (i.e. 0.2°, 2.7°, 3.9° and 6.6° valgus). Loading and boundary conditions were assigned based on subject-specific kinematic and kinetic data from gait analysis. Multiobjective optimization was used to identify the final alignment that balanced compressive and shear forces between medial and lateral knee compartments. Peak stresses decreased in the medial and increased in the lateral compartment as the HKA was shifted into valgus, with balanced loading occurring at angles of 4.3° and 2.9° valgus for the femoral and tibial cartilage respectively. The concept introduced here provides a platform for non-invasive, patient-specific preoperative planning of the osteotomy for medial compartment knee osteoarthritis. Copyright © 2017 IPEM. Published by Elsevier Ltd. All rights reserved.

  14. Translational and rotational knee joint stability in anterior and posterior cruciate-retaining knee arthroplasty.

    PubMed

    Lo, JiaHsuan; Müller, Otto; Dilger, Torsten; Wülker, Nikolaus; Wünschel, Markus

    2011-12-01

    This study investigated passive translational and rotational stability properties of the intact knee joint, after bicruciate-retaining bi-compartmental knee arthroplasty (BKA) and after posterior cruciate retaining total knee arthroplasty (TKA). Fourteen human cadaveric knee specimens were used in this study, and a robotic manipulator with six-axis force/torque sensor was used to test the joint laxity in anterior-posterior translation, valgus-varus, and internal-external rotation. The results show the knee joint stability after bicruciate-retaining BKA is similar to that of the native knee. On the other hand, the PCL-retaining TKA results in inferior joint stability in valgus, varus, external rotation, anterior and, surprisingly, posterior directions. Our findings suggest that, provided functional ligamentous structures, bicruciate-retaining BKA is a biomechanically attractive treatment for joint degenerative disease. Copyright © 2010 Elsevier B.V. All rights reserved.

  15. Whole-body vibration and the prevention and treatment of delayed-onset muscle soreness.

    PubMed

    Aminian-Far, Atefeh; Hadian, Mohammad-Reza; Olyaei, Gholamreza; Talebian, Saeed; Bakhtiary, Amir Hoshang

    2011-01-01

    Numerous recovery strategies have been used in an attempt to minimize the symptoms of delayed-onset muscle soreness (DOMS). Whole-body vibration (WBV) has been suggested as a viable warm-up for athletes. However, scientific evidence to support the protective effects of WBV training (WBVT) on muscle damage is lacking. To investigate the acute effect of WBVT applied before eccentric exercise in the prevention of DOMS. Randomized controlled trial. University laboratory. A total of 32 healthy, untrained volunteers were randomly assigned to either the WBVT (n  =  15) or control (n  =  17) group. Volunteers performed 6 sets of 10 maximal isokinetic (60°/s) eccentric contractions of the dominant-limb knee extensors on a dynamometer. In the WBVT group, the training was applied using a vibratory platform (35 Hz, 5 mm peak to peak) with 100° of knee flexion for 60 seconds before eccentric exercise. No vibration was applied in the control group. Muscle soreness, thigh circumference, and pressure pain threshold were recorded at baseline and at 1, 2, 3, 4, 7, and 14 days postexercise. Maximal voluntary isometric and isokinetic knee extensor strength were assessed at baseline, immediately after exercise, and at 1, 2, 7, and 14 days postexercise. Serum creatine kinase was measured at baseline and at 1, 2, and 7 days postexercise. The WBVT group showed a reduction in DOMS symptoms in the form of less maximal isometric and isokinetic voluntary strength loss, lower creatine kinase levels, and less pressure pain threshold and muscle soreness (P < .05) compared with the control group. However, no effect on thigh circumference was evident (P < .05). Administered before eccentric exercise, WBVT may reduce DOMS via muscle function improvement. Further investigation should be undertaken to ascertain the effectiveness of WBVT in attenuating DOMS in athletes.

  16. Total or Partial Knee Arthroplasty Trial - TOPKAT: study protocol for a randomised controlled trial

    PubMed Central

    2013-01-01

    Background In the majority of patients with osteoarthritis of the knee the disease originates in the medial compartment. There are two fundamentally different approaches to knee replacement for patients with unicompartmental disease: some surgeons feel that it is always best to replace both the knee compartments with a total knee replacement (TKR); whereas others feel it is best to replace just the damaged component of the knee using a partial or unicompartment replacement (UKR). Both interventions are established and well-documented procedures. Little evidence exists to prove the clinical and cost-effectiveness of either management option. This provides an explanation for the high variation in treatment of choice by individual surgeons for the same knee pathology. The aim of the TOPKAT study will be to assess the clinical and cost effectiveness of TKRs compared to UKRs in patients with medial compartment osteoarthritis. Methods/Design The design of the study is a single layer multicentre superiority type randomised controlled trial of unilateral knee replacement patients. Blinding will not be possible as the surgical scars for each procedure differ. We aim to recruit 500 patients from approximately 28 secondary care orthopaedic units from across the UK including district general and teaching hospitals. Participants will be randomised to either UKR or TKR. Randomisation will occur using a web-based randomisation system. The study is pragmatic in terms of implant selection for the knee replacement operation. Participants will be followed up for 5 years. The primary outcome is the Oxford Knee Score, which will be collected via questionnaires at 2 months, 1 year and then annually to 5 years. Secondary outcomes will include cost-effectiveness, patient satisfaction and complications data. Trial registration Current Controlled Trials ISRCTN03013488; ClinicalTrials.gov Identifier: NCT01352247 PMID:24028414

  17. Disease activity, knee function, and walking ability in patients with rheumatoid arthritis 10 years after primary total knee arthroplasty.

    PubMed

    Nishikawa, Masataka; Owaki, Hajime; Takahi, Koichiro; Fuji, Takeshi

    2014-04-01

    To evaluate disease activity, knee function, and walking ability of patients with rheumatoid arthritis (RA) over 10 years after total knee arthroplasty (TKA). Four men and 26 women (mean age, 59.9 years) underwent 42 TKAs for RA with a mean duration of 151.3 months and were followed up for a mean of 142.3 months. Preoperatively, disease activity was assessed by C-reactive protein (CRP) level only, and the range of knee motion was recorded. At the final follow-up, tender joint count, swollen joint count, visual analogue scale of RA symptoms, and the Modified Health Assessment Questionnaire (MHAQ) score were assessed. Disease activity was evaluated using CRP, matrix metalloproteinase-3, and Disease Activity Score. Range of motion and Knee Society knee and function scores were also assessed. The use of methotrexate increased from 4 patients preoperatively to 20 patients at the final follow-up (p<0.001), and the mean dose increased from 3.9 to 6.3 mg/week (p<0.001). Among the 30 patients, the mean CRP level decreased from 2.63 mg/dl preoperatively to 0.61 mg/dl at the final follow-up (p<0.001). Disease activity was controlled. At the final follow-up, disease activity was in remission in 10 patients, low in 11, and moderate in 9. The mean Knee Society knee score was excellent (91.0), but the mean function score was poor (57.0) and diverse. Severe walking disability (function score, <40) was noted in 8 patients (11 TKAs). Knee and function scores did not correlate. Walking ability in patients with RA after TKA was generally poor. Poor function was associated with a history of spinal or lower extremity fracture surgery and the MHAQ score.

  18. Post-Discharge Care Duration, Charges, and Outcomes Among Medicare Patients After Primary Total Hip and Knee Arthroplasty.

    PubMed

    Ponnusamy, Karthikeyan E; Naseer, Zan; El Dafrawy, Mostafa H; Okafor, Louis; Alexander, Clayton; Sterling, Robert S; Khanuja, Harpal S; Skolasky, Richard L

    2017-06-07

    In April 2016, the U.S. Centers for Medicare & Medicaid Services initiated mandatory 90-day bundled payments for total hip and knee arthroplasty for much of the country. Our goal was to determine duration of care, 90-day charges, and readmission rates by discharge disposition and U.S. region after hip or knee arthroplasty. Using the 2008 Medicare Provider Analysis and Review database 100% sample, we identified patients who had undergone elective primary total hip or knee arthroplasty. We collected data on patient age, sex, comorbidities, U.S. Census region, discharge disposition, duration of care, 90-day charges, and readmission. Multivariate regression was used to assess factors associated with readmission (logistic) and charges (linear). Significance was set at p < 0.01. Patients undergoing 138,842 total hip arthroplasties were discharged to home (18%), home health care (34%), extended-care facilities (35%), and inpatient rehabilitation (13%); patients undergoing 329,233 total knee arthroplasties were discharged to home (21%), home health care (38%), extended-care facilities (31%), and inpatient rehabilitation (10%). Patients in the Northeast were more likely to be discharged to extended-care facilities or inpatient rehabilitation than patients in other regions. Patients in the West had the highest 90-day charges. Approximately 70% of patients were discharged home from extended-care facilities, whereas after inpatient rehabilitation, >50% of patients received home health care. Among those discharged to home, 90-day readmission rates were highest in the South (9.6%) for patients undergoing total hip arthroplasty and in the Midwest (8.7%) and the South (8.5%) for patients undergoing total knee arthroplasty. Having ≥4 comorbidities, followed by discharge to inpatient rehabilitation or an extended-care facility, had the strongest associations with readmission, whereas the region of the West and the discharge disposition to inpatient rehabilitation had the strongest association with higher charges. Among Medicare patients, discharge disposition and number of comorbidities were most strongly associated with readmission. Inpatient rehabilitation and the West region had the strongest associations with higher charges. Prognostic Level IV. See Instructions for Authors for a complete description of levels of evidence.

  19. Is knee function better with contemporary modular bicompartmental arthroplasty compared to total knee arthroplasty? Short-term outcomes of a prospective matched study including 68 cases.

    PubMed

    Parratte, S; Ollivier, M; Opsomer, G; Lunebourg, A; Argenson, J-N; Thienpont, E

    2015-09-01

    Bicompartmental knee arthroplasty (BKA) was developed to treat medial tibiofemoral and patellofemoral osteoarthritis while preserving the anterior cruciate ligament to optimise knee kinematics. Our objective here was to compare the probability of achieving forgotten knee status and the functional outcomes at least two years after BKA versus total knee arthroplasty (TKA). We hypothesised that contemporary modular BKA produced better functional outcomes than TKA after at least two years, for patients with similar pre-operative osteoarthritic lesions. We conducted a two-centre prospective controlled study of 34consecutive patients who underwent BKA between January 2008 and January 2011. Each patient was matched on age, gender, body mass index, preoperative range of knee flexion, centre, and surgeon to a patient treated with TKA. An independent observer evaluated all 68 patients after six and 12months then once a year. Forgotten knee status was defined as a 100/100 value of the Forgotten Joint Score (FJS-12) and each of the five KOOS subscales. We also compared the two groups for knee range of motion, Knee Society Scores (KSSs), Timed Up-and-Go test (TUG), and UCLA Activity Score. At a mean follow-up of 3.8±1.7 years, the probability of forgotten knee status was significantly higher in the BKA group (odds ratio, 4.64; 95% confidence interval, 1.63-13.21; P=0.007, Chi(2) test). Mean post-operative extension was not significantly different between the groups, whereas mean range of knee flexion was significantly greater in the BKA group (130°±6° vs. 125°±8° after TKA; P=0.03). The BKA group had significantly higher mean values for the knee and function KSSs, TUG test, and UCLA score (P<0.04 for all four comparisons). After at least two years, contemporary unlinked BKA was associated with greater comfort during everyday activities (forgotten knee) and better functional outcomes, compared to TKA. These short-term results require validation in randomised trials with longer follow-ups. III, case-control study. Copyright © 2015 Elsevier Masson SAS. All rights reserved.

  20. Correlation between varus knee malalignment and patellofemoral osteoarthritis.

    PubMed

    Otsuki, Shuhei; Nakajima, Mikio; Okamoto, Yoshinori; Oda, Shuhei; Hoshiyama, Yoshiaki; Iida, Go; Neo, Masashi

    2016-01-01

    To evaluate the relationship between patellofemoral osteoarthritis (OA) and varus OA of the knee with a focus on the location of joint space narrowing. Eighty-five patients scheduled to undergo total knee arthroplasty caused by varus OA were enrolled in this study. The relationship between patellofemoral OA and varus knee malalignment was elucidated. To determine the alignment of the patellofemoral joint in varus knees, patellar tilt, and the tibial tuberosity-trochlear groove (TT-TG) distance were measured, and patellofemoral OA was classified using computed tomography. The femorotibial angles in patients with stage II-IV patellofemoral OA were significantly larger than those in patients with stage I patellofemoral OA, and the patellar tilt in patients with stage II-IV patellofemoral OA and the TT-TG distance in patients with stage IV patellofemoral OA were significantly larger than those in patients with stage I patellofemoral OA. The TT-TG distance was strongly correlated with patellar tilt (R(2) = 0.41, P < 0.001). Patellofemoral joint space narrowing was mainly noted at the lateral facet, and it was found on both sides as patellofemoral OA worsened. Varus knee malalignment was induced by patellofemoral OA, especially at the lateral facet. Patellar tilt and the TT-TG distance are considered critical factors for the severity of patellofemoral OA. Understanding the critical factors for patellofemoral OA in varus knees such as the TT-TG distance and patellar will facilitate the prevention of patellofemoral OA using procedures such as high tibial osteotomy and total knee arthroplasty to correct knee malalignment. Retrospective cohort study, Level III.

  1. Effects of a 10-week toe-out gait modification intervention in people with medial knee osteoarthritis: a pilot, feasibility study.

    PubMed

    Hunt, M A; Takacs, J

    2014-07-01

    To examine the feasibility of a 10-week gait modification program in people with medial tibiofemoral knee osteoarthritis (OA), and to assess changes in clinical and biomechanical outcomes. Fifteen people with medial knee OA completed 10 weeks of gait modification focusing on increasing toe-out angle during stance 10° compared to their self-selected angle measured at baseline. In addition to adherence and performance difficulty outcomes, knee joint symptoms (Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) pain subscale and total score, numerical rating scale (NRS) of pain), and knee joint loading during gait (late stance peak knee adduction moment (KAM)) were assessed. Participants were able to perform the toe-out gait modification program with minimal to moderate difficulty, and exhibited significant increases in self-selected toe-out angle during walking (P < 0.001). Joint discomfort was reported by five participants (33%) in the hip or knee joints, though none lasted longer than 2 weeks. Participants reported statistically significant reductions in WOMAC pain (P = 0.02), NRS pain (P < 0.001), WOMAC total score (P = 0.02), and late stance KAM (P = 0.04). These preliminary findings suggest that toe-out gait modification is feasible in people with medial compartment knee OA. Preliminary changes in clinical and biomechanical outcomes provide the impetus for conducting larger scale studies of gait modification in people with knee OA to confirm these findings. Copyright © 2014 Osteoarthritis Research Society International. Published by Elsevier Ltd. All rights reserved.

  2. Gender differences in knee morphology and the prospects for implant design in total knee replacement.

    PubMed

    Asseln, Malte; Hänisch, Christoph; Schick, Fabian; Radermacher, Klaus

    2018-05-14

    Morphological differences between female and male knees have been reported in the literature, which led to the development of so-called gender-specific implants. However, detailed morphological descriptions covering the entire joint are rare and little is known regarding whether gender differences are real sexual dimorphisms or can be explained by overall differences in size. We comprehensively analysed knee morphology using 33 features of the femur and 21 features of the tibia to quantify knee shape. The landmark recognition and feature extraction based on three-dimensional surface data were fully automatically applied to 412 pathological (248 female and 164 male) knees undergoing total knee arthroplasty. Subsequently, an exploratory statistical analysis was performed and linear correlation analysis was used to investigate normalization factors and gender-specific differences. Statistically significant differences between genders were observed. These were pronounced for distance measurements and negligible for angular (relative) measurements. Female knees were significantly narrower at the same depth compared to male knees. The correlation analysis showed that linear correlations were higher for distance measurements defined in the same direction. After normalizing the distance features according to overall dimensions in the direction of their definition, gender-specific differences disappeared or were smaller than the related confidence intervals. Implants should not be linearly scaled according to one dimension. Instead, features in medial/lateral and anterior/posterior directions should be normalized separately (non-isotropic scaling). However, large inter-individual variations of the features remain after normalization, suggesting that patient-specific design solutions are required for an improved implant design, regardless of gender. Copyright © 2018 Elsevier B.V. All rights reserved.

  3. Femoro-tibial kinematics after TKA in fixed- and mobile-bearing knees in the sagittal plane.

    PubMed

    Daniilidis, Kiriakos; Höll, Steffen; Gosheger, Georg; Dieckmann, Ralf; Martinelli, Nicolo; Ostermeier, Sven; Tibesku, Carsten O

    2013-10-01

    Lack of the anterior cruciate ligament in total knee arthroplasty results in paradoxical movement of the femur as opposed to the tibia under deep flexion. Total knee arthroplasty with mobile-bearing inlays has been developed to provide increased physiological movement of the knee joint and to reduce polyethylene abrasion. The aim of this study was to perform an in vitro analysis of the kinematic movement in the sagittal plane in order to show differences between fixed- and mobile-bearing TKA in comparison with the natural knee joint. Seven knee joints of human cadaver material were used in a laboratory experiment. Fixed- and mobile-bearing inlays were tested in sequences under isokinetic extension in so-called kinemator for knee joints, which can simulate muscular traction power by the use of hydraulic cylinders, which crossover the knee joint. As a target parameter, the a.p. translation of the tibio-femoral relative movement was measured in the sagittal plane under ultrasound (Zebris) control. The results show a reduced tibial a.p. translation in relation to the femur in the bearing group compared to the natural joint. In the Z-axis, between 110° and 50° of flexion, linear movement decreases towards caudal movement under extension. Admittedly, the study did not show differences in the movement pattern between "mobile-bearing" and "fixed-bearing" prostheses. Results of this study cannot prove functional advantages of mobile-bearing prostheses for the knee joint kinematic after TKA. Both types of prostheses show typical kinematics of an anterior instability, hence they were incapable of performing physiological movement.

  4. Clinical Outcome of Medial Pivot Compared With Press-Fit Condylar Sigma Cruciate-Retaining Mobile-Bearing Total Knee Arthroplasty.

    PubMed

    Kim, Young-Hoo; Park, Jang-Won; Kim, Jun-Shik

    2017-10-01

    The purpose of this study was to compare the long-term clinical results, radiographic results, range of knee motion, patient satisfaction, and the survival rate of Medial-Pivot posterior cruciate-substituting, knee prosthesis and a press-fit condylar (PFC) Sigma cruciate-retaining mobile-bearing knee prosthesis in the same patients. One hundred eighty-two patients received Medial-Pivot knee prosthesis in one knee and a PFC Sigma knee prosthesis in the contralateral knee. The minimum duration of follow-up was 11 years (range, 11-12.6 years). The knees with a Medial-Pivot knee prosthesis had significantly worse results than those with a PFC Sigma knee prosthesis at the final follow-up with regard to the mean postoperative Knee Society knee scores (90 compared with 95 points), Western Ontario and McMaster Universities Osteoarthritis Index score (25 compared with 18 points), and range of knee motion (117° compared with 128°). Patients were more satisfied with PFC Sigma knee prosthesis (93%) than with Medial-Pivot knee prosthesis (75%). Complication rates were significantly higher in the Medial-Pivot knee group (26%) than those in the PFC Sigma knee group (6.5%). Radiographic results and survival rates (99% compared with 99.5%) were similar between the 2 groups. Although the long-term fixation and survival rate of both Medial-Pivot and PFC Sigma prostheses were similar, we observed a worse knee score, worse range of knee motion, and patient satisfaction was less in the Medial-Pivot knee group than in the PFC Sigma knee group. Furthermore, complication rate was also higher in the Medial-Pivot knee group than the other group. Copyright © 2017 Elsevier Inc. All rights reserved.

  5. Early outcomes of patella resurfacing in total knee arthroplasty

    PubMed Central

    Clements, Warren J; Miller, Lisa; Whitehouse, Sarah L; Graves, Stephen E; Ryan, Philip

    2010-01-01

    Background Patella resurfacing in total knee arthroplasty is a contentious issue. The literature suggests that resurfacing of the patella is based on surgeon preference, and little is known about the role and timing of resurfacing and how this affects outcomes. Methods We analyzed 134,799 total knee arthroplasties using data from the Australian Orthopaedic Association National Joint Replacement Registry. Hazards ratios (HRs) were used to compare rates of early revision between patella resurfacing at the primary procedure (the resurfacing group, R) and primary arthroplasty without resurfacing (no-resurfacing group, NR). We also analyzed the outcomes of NR that were revised for isolated patella addition. Results At 5 years, the R group showed a lower revision rate than the NR group: cumulative per cent revision (CPR) 3.1% and 4.0%, respectively (HR = 0.75, p < 0.001). Revisions for patellofemoral pain were more common in the NR group (17%) than in the R group (1%), and “patella only” revisions were more common in the NR group (29%) than in the R group (6%). Non-resurfaced knees revised for isolated patella addition had a higher revision rate than patella resurfacing at the primary procedure, with a 4-year CPR of 15% and 2.8%, respectively (HR = 4.1, p < 0.001). Interpretation Rates of early revision of primary total knees were higher when the patella was not resurfaced, and suggest that surgeons may be inclined to resurface later if there is patellofemoral pain. However, 15% of non-resurfaced knees revised for patella addition are re-revised by 4 years. Our results suggest an early beneficial outcome for patella resurfacing at primary arthroplasty based on revision rates up to 5 years. PMID:19968604

  6. Measurement of knee stiffness and laxity in patients with documented absence of the anterior cruciate ligament.

    PubMed

    Markolf, K L; Kochan, A; Amstutz, H C

    1984-02-01

    Thirty-five patients with documented absence of the anterior cruciate ligament were tested on the University of California, Los Angeles, instrumented clinical knee-testing apparatus and we measured the response curves for the following testing modes: anterior-posterior force versus displacement at full extension and at 20 and 90 degrees of flexion; varus-valgus moment versus angulation at full extension and 20 degrees of flexion; and tibial torque versus rotation at 20 degrees of flexion. Absolute values of stiffness and laxity and right-left differences for these injured knees were compared with identical quantities measured previously for a control population of forty-nine normal subjects with no history of treatment for injury to the knee. For both the uninjured knees and the knees without an anterior cruciate ligament, at 20 and 90 degrees of flexion the anterior-posterior laxity was greatest at approximately 15 degrees of external rotation of the foot. The injured knees demonstrated significantly increased total anterior-posterior laxity and decreased anterior stiffness when compared with the uninjured knees in all tested positions of the foot and knee. The mean increase in paired anterior-posterior laxity for the injured knees in this group of patients at +/- 200 newtons of applied anterior-posterior force was 3.1 millimeters (+39 per cent) at full extension, 5.5 millimeters (+57 per cent) at 20 degrees of flexion, and 2.5 millimeters (+34 per cent) at 90 degrees of flexion. The mean reduction in anterior stiffness for injured knees was also greatest (-54 per cent) at 20 degrees of knee flexion. Only slight reduction in posterior stiffness (-16 per cent) was measured at 20 degrees of flexion, and this probably reflected the presence of associated capsular and meniscal injuries. In the group of anterior cruciate-deficient knees, the patients with an absent medial meniscus showed greater total anterior-posterior laxity in all three positions of knee flexion than did the patients with an intact or torn meniscus. Varus-valgus laxity at full extension increased an average of 1.7 degrees (+36 per cent) for the injured knees, while varus and valgus stiffness decreased 21 per cent and 24 per cent. Absence of the medial meniscus (in a knee with absence of the anterior cruciate ligament) increased varus-valgus laxity at zero and 20 degrees of flexion.(ABSTRACT TRUNCATED AT 400 WORDS)

  7. [False aneurysm of the lateral superior genicular artery. A complication after the implantation of a knee prosthesis].

    PubMed

    Kirschner, S; Konrad, T; Weil, E J; Bühler, M

    2004-07-01

    Arterial complications after total knee arthroplasty are rare. If the formation of a false aneurysm does occur, it usually affects the popliteal artery. We report the case of an 77 year old female with a false aneurysm of the lateral superior genicular artery. The patient was suffering from gonarthrosis and received a duocondylar knee replacement without resurfacing of the patella. Postoperatively, she reported anterior knee pain and a revision of the joint with lateral release was carried out. In the third postoperative week, a painful swelling in the lateral and superior aspect of the knee occurred. A scintigraphic investigation with enrichment in the early period was misinterpreted as infection. Ultrasonographic and angiographic investigations gave the right diagnosis of a false aneurysm. In the same angiographic investigation, the aneurysm could be cured by coil embolisation. The interval between the operation leading to the problem and the formation of the aneurysm, as well as the low incidence of this complication, made it hard to diagnose. Ultrasonographic and angiographic examinations allow for proper diagnosis in cases of unclear painful swellings. When dealing with an arterial complication following total knee arthroplasty, a specialized radiologist or vascular surgeon should be consulted immediately.

  8. Relationship between Lateral Femoral Bowing and Varus Knee Deformity Based on Two-Dimensional Assessment of Side-to-Side Differences.

    PubMed

    Cho, Myung-Rae; Lee, Young Sik; Choi, Won-Kee

    2018-03-01

    The objective was to evaluate the relationship between side-to-side differences of lateral femoral bowing and varus knee deformity based on two-dimensional (2D) assessment in unilateral total knee arthroplasty (TKA). A total of 143 patients with varus knee osteoarthritis who underwent unilateral TKA were enrolled. We evaluated the side-to-side differences of the frontal lower limb alignment by assessing lateral femoral bowing, anatomical medial distal femoral angle, and anatomical medial proximal tibial angle (aMPTA). The average values of all anatomical indices were significantly different between the operated side and the non-operated side (p<0.05). The side-to-side difference in hip knee ankle (HKA) angle had a statistically significant correlation with that in lateral femoral bowing (intraclass correlation coefficient, 0.259; p=0.002) and that in aMPTA. Linear regression analysis showed 0.199° of side-to-side difference in lateral femoral bowing was associated with 1° of side-to-side difference in bilateral HKA angle. The side-to-side difference in lateral femoral bowing showed a tendency to increase in proportion to varus knee deformity based on 2D assessment in unilateral TKA patients.

  9. Total knee arthroplasty with computer-assisted navigation more closely replicates normal knee biomechanics than conventional surgery.

    PubMed

    McClelland, Jodie A; Webster, Kate E; Ramteke, Alankar A; Feller, Julian A

    2017-06-01

    Computer-assisted navigation in total knee arthroplasty (TKA) reduces variability and may improve accuracy in the postoperative static alignment. The effect of navigation on alignment and biomechanics during more dynamic movements has not been investigated. This study compared knee biomechanics during level walking of 121 participants: 39 with conventional TKA, 42 with computer-assisted navigation TKA and 40 unimpaired control participants. Standing lower-limb alignment was significantly closer to ideal in participants with navigation TKA. During gait, when differences in walking speed were accounted for, participants with conventional TKA had less knee flexion during stance and swing than controls (P<0.01), but there were no differences between participants with navigation TKA and controls for the same variables. Both groups of participants with TKA had lower knee adduction moments than controls (P<0.01). In summary, there were fewer differences in the biomechanics of computer-assisted navigation TKA patients compared to controls than for patients with conventional TKA. Computer-assisted navigation TKA may restore biomechanics during walking that are closer to normal than conventional TKA. Copyright © 2017 Elsevier B.V. All rights reserved.

  10. Total Knee Arthroplasty for Knee Osteoarthritis: Support for a Foregone Conclusion?

    PubMed

    Steinhaus, Michael E; Christ, Alexander B; Cross, Michael B

    2017-07-01

    Total knee arthroplasty (TKA) is generally accepted as the definitive treatment for advanced knee arthritis after patients fail nonoperative treatments; however, the safety and efficacy of TKA compared to continued nonoperative treatment has never been proven in high-quality, randomized controlled trials. Recently, a 2015 Danish study published a 12-month follow-up on a cohort of patients randomized to either a TKA or continued nonsurgical management for advanced knee osteoarthritis (OA). The authors reported significantly greater improvement in the TKA group in functional outcome scores such as the overall Knee Injury and Osteoarthritis Outcome Score (KOOS 4 score), the KOOS subscales, EQ-5D descriptive index, and timed get up-and-go and 20-m walk tests; however, patients in the TKA did suffer significantly more serious adverse events (SAE). The authors concluded that TKA combined with additional nonoperative care postoperatively is more efficacious than nonsurgical treatment alone in terms of improving pain, function, and quality of life at 12 months but is associated with more SAE. The purpose of this review is to identify the strengths and weaknesses of this trial, interpret its outcomes within the context of prior literature, and evaluate the validity of its conclusions.

  11. Kinematic alignment technique for total hip and knee arthroplasty

    PubMed Central

    Rivière, Charles; Lazic, Stefan; Villet, Loïc; Wiart, Yann; Allwood, Sarah Muirhead; Cobb, Justin

    2018-01-01

    Conventional techniques for hip and knee arthroplasty have led to good long-term clinical outcomes, but complications remain despite better surgical precision and improvements in implant design and quality. Technological improvements and a better understanding of joint kinematics have facilitated the progression to ‘personalized’ implant positioning (kinematic alignment) for total hip (THA) and knee (TKA) arthroplasty, the true value of which remains to be determined. By achieving a true knee resurfacing, the kinematic alignment (KA) technique for TKA aims at aligning the components with the physiological kinematic axes of the knee and restoring the constitutional tibio-femoral joint line frontal and axial orientation and soft-tissue laxity. The KA technique for THA aims at restoring the native ‘combined femoro-acetabular anteversion’ and the hip’s centre of rotation, and occasionally adjusting the cup position and design based on the assessment of the individual spine-hip relation. The key element for optimal prosthetic joint kinematics (hip or knee) is to reproduce the femoral anatomy. The transverse acetabular ligament (TAL) is the reference landmark to adjust the cup position. Cite this article: EFORT Open Rev 2018;3:98-105. DOI: 10.1302/2058-5241.3.170022 PMID:29657851

  12. Achieving Consensus on Total Joint Replacement Trial Outcome Reporting Using the OMERACT Filter: Endorsement of the Final Core Domain Set for Total Hip and Total Knee Replacement Trials for Endstage Arthritis.

    PubMed

    Singh, Jasvinder A; Dowsey, Michelle M; Dohm, Michael; Goodman, Susan M; Leong, Amye L; Scholte Voshaar, Marieke M J H; Choong, Peter F

    2017-11-01

    Discussion and endorsement of the OMERACT total joint replacement (TJR) core domain set for total hip replacement (THR) and total knee replacement (TKR) for endstage arthritis; and next steps for selection of instruments. The OMERACT TJR working group met at the 2016 meeting at Whistler, British Columbia, Canada. We summarized the previous systematic reviews, the preliminary OMERACT TJR core domain set and results from previous surveys. We discussed preliminary core domains for TJR clinical trials, made modifications, and identified challenges with domain measurement. Working group participants (n = 26) reviewed, clarified, and endorsed each of the inner and middle circle domains and added a range of motion domain to the research agenda. TJR were limited to THR and TKR but included all endstage hip and knee arthritis refractory to medical treatment. Participants overwhelmingly endorsed identification and evaluation of top instruments mapping to the core domains (100%) and use of subscales of validated multidimensional instruments to measure core domains for the TJR clinical trial core measurement set (92%). An OMERACT core domain set for hip/knee TJR trials has been defined and we are selecting instruments to develop the TJR clinical trial core measurement set to serve as a common foundation for harmonizing measures in TJR clinical trials.

  13. An Examination of the Effects of Pre-Surgical Education on Patient Expectations in Total Knee Arthroplasties

    ERIC Educational Resources Information Center

    Montez-Ray, Natasha Dawn

    2011-01-01

    As patients prepare for total-knee arthroplasty surgery, they have numerous expectations related to their long-term recovery and function. This research discerned whether the use of a pre-surgical patient education class with an additional long-term expectation module addressing recovery during the first 12 months after surgery was more effective…

  14. Global scientific production in the field of knee arthroplasty: A cross-sectional survey of research activities.

    PubMed

    Wang, Lu; Li, Lingxia; Cheng, Cai; Tian, Hua; Li, Yang; Zhao, Minwei

    2017-06-01

    Objective To determine the quantity and quality of articles in the field of knee arthroplasty worldwide and elucidate the characteristics of global scientific production. Methods Web of Science was used to identify articles in the field of knee arthroplasty from 2011 to 2015. The total number of papers, number of papers per capita, total number of citations, and mean number of citations were collected. Results In total, 11,590 papers were identified. The number of publications significantly increased from 2011 to 2015. Most originated from North America, East Asia, and West Europe. Most (88.51%) were from high-income countries, 11.48% were from middle-income countries, and only 0.01% were from lower-income countries. The United States had the most articles and total citations. Sweden had the highest mean citations, followed by Denmark and Canada. However, when adjusted by population size, Denmark had the most articles per million population, followed by Switzerland and the Netherlands. Conclusions The number of knee arthroplasty publications has rapidly increased in recent years. The United States is the most prolific, but some European countries are more productive relative to their population.

  15. Resection and Resolution of Bone Marrow Lesions Associated with an Improvement of Pain after Total Knee Replacement: A Novel Case Study Using a 3-Tesla Metal Artefact Reduction MRI Sequence.

    PubMed

    Kurien, Thomas; Kerslake, Robert; Haywood, Brett; Pearson, Richard G; Scammell, Brigitte E

    2016-01-01

    We present our case report using a novel metal artefact reduction magnetic resonance imaging (MRI) sequence to observe resolution of subchondral bone marrow lesions (BMLs), which are strongly associated with pain, in a patient after total knee replacement surgery. Large BMLs were seen preoperatively on the 3-Tesla MRI scans in a patient with severe end stage OA awaiting total knee replacement surgery. Twelve months after surgery, using a novel metal artefact reduction MRI sequence, we were able to visualize the bone-prosthesis interface and found complete resection and resolution of these BMLs. This is the first reported study in the UK to use this metal artefact reduction MRI sequence at 3-Tesla showing that resection and resolution of BMLs in this patient were associated with an improvement of pain and function after total knee replacement surgery. In this case it was associated with a clinically significant improvement of pain and function after surgery. Failure to eradicate these lesions may be a cause of persistent postoperative pain that is seen in up to 20% of patients following TKR surgery.

  16. Clinical Evaluation of Efficacy and Performance of All-Poly Tibial Freedom® Total Knee System for Treating Osteoarthritis Patients: Three-Year Follow Up Study.

    PubMed

    Singh, Avatar; Singh, Kanwar Kulwinder

    2017-09-01

    Advancement in technology in terms of design and building materials has made Total Knee Replacement (TKR) a highly effective, safe, and predictable orthopedic procedure. To review the clinical outcomes for efficacy and performance of Freedom Total Knee System for the management of Osteoarthritis (OA), at a minimum of three years follow up. For this retrospective, post-marketing study, clinical data of patients treated with Freedom Total Knee System was retrieved from the clinical records after approval from the Institutional Ethics Committee . All the patients above the age of 18 years who completed at least three years after TKR were observed for the study purpose. Patients treated for OA were included while the patients who received the implant for treatment of rheumatoid arthritis and traumatic injury were excluded. Factors such as aseptic loosening, implant failure, and need for revision surgery were observed to evaluate implant performance. Cases were recruited for clinical assessment of primary efficacy endpoint in terms of post-surgery maximun range of motion. Secondary efficacy endpoint was to determine the clinical and social quality of life as per the American Knee Society Score (AKSS) and Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) pain and stiffness scores. A total of 158 patients who had 191 TKR were observed for performance. The mean age of the patients was 67.67 years; mean BMI was 28.97±3.33, and the group comprised of 43% men and 57% women. Telephonic follow up at three years of 158 patients identified that none of them required revision surgery or had aseptic loosening suggesting excellent performance. Final clinical follow up at three years was available for only 35 patients (41 knee implants). The range of motion significantly improved from preoperative 104°±5.67° (range, 85°-119°) to 119.8°±11.05° (98°-123°) at follow-up (p<0.05). There was a significant improvement in clinical and functional AKSS score and WOMAC score at follow-up. The evaluation of Freedom Total Knee System for TKR in treating OA, at a minimum of three years follow up showed excellent outcomes in terms of performance, range of motion, reduced postoperative stiffness and pain, and improved functionality.

  17. Clinical Evaluation of Efficacy and Performance of All-Poly Tibial Freedom® Total Knee System for Treating Osteoarthritis Patients: Three-Year Follow Up Study

    PubMed Central

    Singh, Kanwar Kulwinder

    2017-01-01

    Introduction Advancement in technology in terms of design and building materials has made Total Knee Replacement (TKR) a highly effective, safe, and predictable orthopedic procedure. Aim To review the clinical outcomes for efficacy and performance of Freedom Total Knee System for the management of Osteoarthritis (OA), at a minimum of three years follow up. Materials and Methods For this retrospective, post-marketing study, clinical data of patients treated with Freedom Total Knee System was retrieved from the clinical records after approval from the Institutional Ethics Committee . All the patients above the age of 18 years who completed at least three years after TKR were observed for the study purpose. Patients treated for OA were included while the patients who received the implant for treatment of rheumatoid arthritis and traumatic injury were excluded. Factors such as aseptic loosening, implant failure, and need for revision surgery were observed to evaluate implant performance. Cases were recruited for clinical assessment of primary efficacy endpoint in terms of post-surgery maximun range of motion. Secondary efficacy endpoint was to determine the clinical and social quality of life as per the American Knee Society Score (AKSS) and Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) pain and stiffness scores. Results A total of 158 patients who had 191 TKR were observed for performance. The mean age of the patients was 67.67 years; mean BMI was 28.97±3.33, and the group comprised of 43% men and 57% women. Telephonic follow up at three years of 158 patients identified that none of them required revision surgery or had aseptic loosening suggesting excellent performance. Final clinical follow up at three years was available for only 35 patients (41 knee implants). The range of motion significantly improved from preoperative 104°±5.67° (range, 85°-119°) to 119.8°±11.05° (98°-123°) at follow-up (p<0.05). There was a significant improvement in clinical and functional AKSS score and WOMAC score at follow-up. Conclusion The evaluation of Freedom Total Knee System for TKR in treating OA, at a minimum of three years follow up showed excellent outcomes in terms of performance, range of motion, reduced postoperative stiffness and pain, and improved functionality. PMID:29207792

  18. Analysis of the Flexion Gap on In Vivo Knee Kinematics Using Fluoroscopy.

    PubMed

    Nakamura, Shinichiro; Ito, Hiromu; Yoshitomi, Hiroyuki; Kuriyama, Shinichi; Komistek, Richard D; Matsuda, Shuichi

    2015-07-01

    There is a paucity of information on the relationships between postoperative knee laxity and in vivo knee kinematics. The correlations were analyzed in 22 knees with axial radiographs and fluoroscopy based 3D model fitting approach after a tri-condylar total knee arthroplasty. During deep knee bend activities, the medial flexion gap had significant correlations with the medial contact point (r=0.529, P=0.011) and axial rotation at full extension. During kneeling activities, a greater medial flexion gap caused larger anterior translation at complete contact (r=0.568, P=0.011). Meanwhile, the lateral flexion gap had less effect. In conclusion, laxity of the medial collateral ligament should be avoided because the magnitude of medial flexion stability was crucial for postoperative knee kinematics. Copyright © 2015 Elsevier Inc. All rights reserved.

  19. [Minimally invasive approaches to hip and knee joints for total joint replacement].

    PubMed

    Rittmeister, M; König, D P; Eysel, P; Kerschbaumer, F

    2004-11-01

    The manuscript features the different minimally invasive approaches to the hip for joint replacement. These include medial, anterior, anterolateral, and posterior approaches. The concept of minimally invasive hip arthroplasty makes sense if it is an integral part of a larger concept to lower postoperative morbidity. Besides minimal soft tissue trauma, this concept involves preoperative patient education, preemptive analgesia, and postoperative physiotherapy. It is our belief that minimal incision techniques for the hip are not suited for all patients and all surgeons. The different minimally invasive approaches to the knee joint for implantation of a knee arthroplasty are described and discussed. There have been no studies published yet that fulfill EBM criteria. The data so far show that minimally invasive approaches and implantation techniques for total knee replacements lead to quicker rehabilitation of patients.

  20. Meta-analysis and systematic review of clinical outcomes comparing mobile bearing and fixed bearing total knee arthroplasty.

    PubMed

    Smith, Holly; Jan, Meryam; Mahomed, Nizar N; Davey, J Rod; Gandhi, Rajiv

    2011-12-01

    Mobile bearing (MB) knee replacements were designed with the goal of increased conformity and decreased bearing wear. We conducted a meta-analysis and systematic review of randomized controlled trials comparing outcomes of MB and fixed bearing (FB) total knee arthroplasty (TKA). We identified 14 studies reporting our primary outcome of Knee Society Scores (KSS). We also pooled data for post-operative range of motion (ROM) and Hospital for Special Surgery scores (HSS). The standard difference in mean outcome scores for KSS and HSS demonstrated no difference between groups (P = .902, and P = .426 respectively). Similarly, the pooled data for ROM showed no difference between groups (P = .265). The results of this study found no significant differences between clinical outcomes of MB and FB TKA. Copyright © 2011 Elsevier Inc. All rights reserved.

Top