Friction pull plug welding: chamfered heat sink pull plug design
NASA Technical Reports Server (NTRS)
Coletta, Edmond R. (Inventor); Cantrell, Mark A. (Inventor)
2002-01-01
Friction Pull Plug Welding (FPPW) is a solid state repair process for defects up to one inch in length, only requiring single sided tooling (OSL) for usage on flight hardware. Experimental data has shown that the mass of plug heat sink remaining above the top of the plate surface after a weld is completed (the plug heat sink) affects the bonding at the plug top. A minimized heat sink ensures complete bonding of the plug to the plate at the plug top. However, with a minimal heat sink three major problems can arise, the entire plug could be pulled through the plate hole, the central portion of the plug could be separated along grain boundaries, or the plug top hat can be separated from the body. The Chamfered Heat Sink Pull Plug Design allows for complete bonding along the ISL interface through an outside diameter minimal mass heat sink, while maintaining enough central mass in the plug to prevent plug pull through, central separation, and plug top hat separation.
Kock, Niels B; Van Susante, Job L C; Buma, Pieter; Van Kampen, Albert; Verdonschot, Nico
2006-06-01
Osteochondral autologous transplantation is used for the treatment of full-thickness articular cartilage lesions of a joint. Press-fit stability is an important factor for good survival of the transplanted plugs. 36 plugs of three different lengths were transplanted in fresh-frozen human knees. On one condyle, 3 plugs were exactly matched to the depth of the recipient site ("bottomed" plugs) and on the opposite condyle 3 plugs were 5 mm shorter than the depth of the recipient site ("unbottomed" plugs). Plugs were left protruding and then pushed in until flush, and then to 2 mm below flush level, using a loading apparatus. Longer plugs needed higher forces to begin displacement. At flush level, bottomed plugs needed significantly higher forces than unbottomed plugs to become displaced below flush level (mean forces of 404 N and 131 N, respectively). Shorter bottomed plugs required higher forces than longer bottomed ones. Bottomed plugs generally provide much more stability than unbottomed ones. Short bottomed plugs are more stable than long bottomed plugs. Thus, in clinical practice it is advisable to use short bottomed plugs. If, however, unbottomed plugs are still chosen, the longer the plug the higher the resulting stability will be because of higher frictional forces.
Wang, Zhenjun; Zeng, Jing; Song, Hao; Li, Feng
2017-05-01
Near-well ultrasonic processing technology attracts more attention due to its simple operation, high adaptability, low cost and no pollution to the formation. Although this technology has been investigated in detail through laboratory experiments and field tests, systematic and intensive researches are absent for certain major aspects, such as whether ultrasonic excitation is better than chemical agent for any plugs removal; whether ultrasound-chemical combination plug removal technology has the best plugs removal effect. In this paper, the comparison of removing drilling fluid plug, paraffin deposition plug, polymer plug and inorganic scale plug using ultrasonic excitation, chemical agent and ultrasound-chemical combination plug removal technology is investigated. Results show that the initial core permeability and ultrasonic frequency play a significant role in plug removal. Ultrasonic excitation and chemical agent have different impact on different plugs. The comparison results show that the effect of removing any plugs using ultrasound-chemicals composite plug removal technology is obviously better than that using ultrasonic excitation or chemical agent alone. Such conclusion proves that ultrasonic excitation and chemical agent can cause synergetic effects. Copyright © 2016 Elsevier B.V. All rights reserved.
Friction pull plug welding: chamfered heat sink pull plug design
NASA Technical Reports Server (NTRS)
Coletta, Edmond R. (Inventor); Cantrell, Mark A. (Inventor)
2005-01-01
The average strength of a pull plug weld is increased and weak bonding eliminated by providing a dual included angle at the top one third of the pull plug. Plugs using the included angle of the present invention had consistent high strength, no weak bonds and were substantially defect free. The dual angle of the pull plug body increases the heat and pressure of the weld in the region of the top one third of the plug. This allows the plug to form a tight high quality solid state bond. The dual angle was found to be successful in elimination of defects on both small and large plugs.
Friction pull plug welding: dual chamfered plate hole
NASA Technical Reports Server (NTRS)
Coletta, Edmond R. (Inventor); Cantrell, Mark A. (Inventor)
2001-01-01
Friction Pull Plug Welding (FPPW) is a solid state repair process for defects up to one inch in length, only requiring single sided tooling (OSL) for usage on flight hardware. Early attempts with FPPW followed the matching plug/plate geometry precedence of the successful Friction Push Plug Welding program, however no defect free welds were achieved due to substantial plug necking and plug rotational stalling. The dual chamfered hole has eliminated plug rotational stalling, both upon initial plug/plate contact and during welding. Also, the necking of the heated plug metal under a tensile heating/forging load has been eliminated through the usage of the dual chamfered plate hole.
NASA Astrophysics Data System (ADS)
Bian, Shiyao; Zheng, Ying; Grotberg, James B.
2008-11-01
Mucus plugging may occur in pulmonary airways in asthma, chronic obstructive pulmonary disease (COPD) and cystic fibrosis. How to clear the mucus plug is essential and of fundamental importance. Mucus is known to have a yield stress and a mucus plug behaves like a solid plug when the applied stresses are below its yield stress τy. When the local stresses reaches τy, the plug starts to move and can be cleared out of the lung. It is then of great importance to examine how the mucus plug deforms and what is the minimum pressure required to initiate its movement. The present study used the finite element method (FEM) to study the stress distribution and deformation of a solid mucus plug under different pressure loads using ANSYS software. The maximum shear stress is found to occur near the rear transition region of the plug, which can lead to local yielding and flow. The critical pressure increases linearly with the plug length and asymptotes when the plug length is larger than the half channel width. Experimentally a mucus simulant is used to study the process of plug deformation and critical pressure difference required for the plug to propagate. Consistently, the fracture is observed to start at the rear transition region where the plug core connects the films. However, the critical pressure is observed to be dependent on not only the plug length but also the interfacial shape.
[Evidence of lacrimal plugs via high resolution ultrasound].
Tost, Frank H W; Darman, Jacques
2003-07-01
The practical value of high-frequency ultrasound (transducer frequency of 20 MHz) for studying lacrimal plugs positioned into canaliculi was proved. Twelve patients with twenty intracanalicular plugs and two punctum plugs were examined via high-frequency B-scan ultrasonography using 20 MHz transducer (model I3 Sacramento, USA). Detection and localisation of the intracanalicular plugs was made by a 20 MHz sector scanner. The ultrasound examinations were performed 1 - 24 month after the placement of lacrimal plugs. After patient's head positioning, the high-frequency ultrasound investigation was done via immersion fluid (2 % methylcellulose). All patients with dry eye treated by lacrimal plug implant showed echographic structure in the lacrimal canaliculus. In transversal echograms it was possible to image both canaliculi together when the lids were half-closed. Contrary to the normal state, it was not necessary to inject viscous fluid into the canaliculus. High-resolution ultrasound was able to differentiate the normal canaliculus from the findings after plug placement. The echograms can vary from one plug type to another. Highly reflective structures were found after the placement of silicone intracanalicular plugs, e. g. HERRICK-Plug. In contrast, the ultrasonic image taken through acrylic polymer intracanalicular plugs showed homogeneous small reflective inner structure, e. g. SMART-Plug. However, smooth and flat acoustic interface between acrylic polymer plug and the lacrimal canaliculus produced strong echoes. 20 MHz ultrasound seems to be well suited for the detection and localisation of intracanalicular plugs. By use of 20 MHz ultrasound scans it is possible to get high-quality images of the intracanalicular plug and around lacrimal canaliculus. Compared with UBM, the depth of penetration is much higher with negligible resolution. On the whole, we believe that 20 MHz ultrasound can become a useful tool for evaluating the placement of intracanalicular plugs after insertion.
Eads, David E.; Biggins, Dean E.
2012-01-01
Black-tailed prairie dogs (Cynomys ludovicianus) can surface-plug openings to a burrow occupied by a black-footed ferret (Mustela nigripes). At a coarse scale, surface plugs are more common in colonies of prairie dogs occupied by ferrets than in colonies without ferrets. However, little is known about spatial and temporal patterns of surface plugging in a colony occupied by ferrets. In a 452-ha colony of black-tailed prairie dogs in South Dakota, we sampled burrow openings for surface plugs and related those data to locations of ferrets observed during spotlight surveys. Of 67,574 burrow openings in the colony between June and September 2007, 3.7% were plugged. In a colony-wide grid of 80 m × 80 m cells, the occurrence of surface plugging (≥1 opening plugged) was greater in cells used by ferrets (93.3% of cells) than in cells not observably used by ferrets (70.6%). Rates of surface plugging (percentages of openings plugged) were significantly higher in cells used by ferrets (median = 3.7%) than in cells without known ferret use (median = 3.2%). Also, numbers of ferret locations in cells correlated positively with numbers of mapped surface plugs in the cells. To investigate surface plugging at finer temporal and spatial scales, we compared rates of surface plugging in 20-m-radius circle-plots centered on ferret locations and in random plots 1–4 days after observing a ferret (Jun–Oct 2007 and 2008). Rates of surface plugging were greater in ferret-plots (median = 12.0%) than in random plots (median = 0%). For prairie dogs and their associates, the implications of surface plugging could be numerous. For instance, ferrets must dig to exit or enter plugged burrows (suggesting energetic costs), and surface plugs might influence microclimates in burrows and consequently influence species that cannot excavate soil (e.g., fleas that transmit the plague bacterium Yersinia pestis).
Aeroacoustics of supersonic jet flows from contoured and solid/porous conical plug-nozzles
NASA Technical Reports Server (NTRS)
Dosanjh, Darshan S.; Das, Indu S.
1987-01-01
The results of an experimental study of the acoustic far-field, the shock associated noise, and the nature of the repetitive shock structure of supersonic jet flows issuing from plug-nozzles having externally-expanded plugs with pointed termination operated at a range of supercritical pressure ratios Xi approaching 2 to 4.5 are reported. The plug of one of these plug-nozzles was contoured. The other plug-nozzles had short conical plugs with either a solid surface or a combination of solid/porous surface of different porosities. The contoured and the uncontoured plug-nozzles had the same throat area and the same annulus-radius ratio K = R sub p/R sub N = 0.43. As the result of modifications of the shock structure, the acoustic performance of improperly expanded jet flows of an externally-expanded short uncontoured plug of an appropriate geometry with suitably perforated plug and a pointed termination, is shown to approach the acoustic performance of a shock-free supersonic jet issuing from an equivalent externally-expanded contoured plug-nozzle.
Friction pull plug welding: top hat plug design
NASA Technical Reports Server (NTRS)
Coletta, Edmond R. (Inventor); Cantrell, Mark A. (Inventor)
2001-01-01
Friction Pull Plug Welding is a solid state repair process for defects up to one inch in length, only requiring single sided tooling, or outside skin line (OSL), for preferred usage on flight hardware. The most prevalent defect associated with Friction Pull Plug Welding (FPPW) was a top side or inside skin line (ISL) lack of bonding. Bonding was not achieved at this location due to the reduction in both frictional heat and welding pressure between the plug and plate at the end of the weld. Thus, in order to eliminate the weld defects and increase the plug strength at the plug `top` a small `hat` section is added to the pull plug for added frictional heating and pressure.
Friction pull plug welding: top hat plug design
NASA Technical Reports Server (NTRS)
Coletta, Edmond R. (Inventor); Cantrell, Mark A. (Inventor)
2002-01-01
Friction Pull Plug Welding is a solid state repair process for defects up to one inch in length, only requiring single sided tooling, or outside skin line (OSL), for preferred usage on flight hardware. The most prevalent defect associated with Friction Pull Plug Welding (FPPW) was a top side or inside skin line (ISL) lack of bonding. Bonding was not achieved at this location due to the reduction in both frictional heat and welding pressure between the plug and plate at the end of the weld. Thus, in order to eliminate the weld defects and increase the plug strength at the plug `top` a small `hat` section is added to the pull plug for added frictional heating and pressure.
Aspergillus fumigatus colonization of punctal plugs.
Tabbara, Khalid F
2007-01-01
Punctal plugs are used in patients with dry eye syndrome to preserve the tears. In this report, I present two cases of Aspergillus fumigatus colonization of punctal plugs. Observational series of two cases. Approval was obtained from the institutional review board. Two men aged 29 and 31 years developed black spots inside the hole of punctal plug, which looked like eyeliner deposits. The deposits inside the hole of the plug in each patient were removed and cultured. Cultures of the two punctal plugs black deposits grew A fumigatus. Bacterial cultures were negative. Colonization of the punctal plug hole with A fumigatus was observed in two cases. It is recommended that punctal plugs be removed in patients undergoing refractive or intraocular procedures or in patients who are receiving topical corticosteroids. Current punctal plugs should be redesigned to avoid the presence of an inserter hole.
New Technology Sparks Smoother Engines and Cleaner Air
NASA Technical Reports Server (NTRS)
2001-01-01
Automotive Resources, Inc. (ARI) has developed a new device for igniting fuel in engines-the SmartPlug.TM SmartPlug is a self-contained ignition system that may be retrofitted to existing spark-ignition and compression-ignition engines. The SmartPlug needs as little as six watts of power for warm-up, and requires no electricity at all when the engine is running. Unlike traditional spark plugs, once the SmartPlug ignites the engine, and the engine heats up, the power supply for the plug is no longer necessary. In the utility industry, SmartPlugs can be used in tractors, portable generators, compressors, and pumps. In addition to general-purpose applications, such as lawn mowers and chainsaws, SmartPlugs can also be used in the recreational, marine, aviation, and automotive industries. Unlike traditional ignition systems, the SmartPlug system requires no distributor, coil points, or moving parts. SmartPlugs are non-fouling, with a faster and cleaner burn than traditional spark plugs. They prevent detonation and are not sensitive to moisture, allowing them to be used on a variety of engines. Other advantages include no electrical noise, no high voltage, exceptionally high altitude capabilities, and better cold-start statistics than those of standard spark ignition systems. Future applications for the SmartPlug are being evaluated by manufacturers in the snowmobile industry.
Method of measuring material properties of rock in the wall of a borehole
Overmier, David K.
1985-01-01
To measure the modulus of elasticity of the rock in the wall of a borehole, a plug is cut in the borehole wall. The plug, its base attached to the surrounding rock, acts as a short column in response to applied forces. A loading piston is applied to the top of the plug and compression of the plug is measured as load is increased. Measurement of piston load and plug longitudinal deformation are made to determine the elastic modulus of the plug material. Poisson's ratio can be determined by simultaneous measurements of longitudinal and lateral deformation of the plug in response to loading. To determine shear modulus, the top of the plug is twisted while measurements are taken of torsional deformation.
Method of measuring material properties of rock in the wall of a borehole
Overmier, D.K.
1984-01-01
To measure the modulus of elasticity of the rock in the wall of a borehole, a plug is cut in the borehole wall. The plug, its base attached to the surrounding rock, acts as a short column in response to applied forces. A loading piston is applied to the top of the plug and compression of the plug is measured as load is increased. Measurements of piston load and plug longitudinal deformation are made to determine the elastic modulus of the plug material. Poisson's ratio can be determined by simultaneous measurements of longitudinal and lateral deformation of the plug in response to loading. To determine shear modulus, the top of the plug is twisted while measurements are taken of torsional deformation.
Adamowicz, S.C.; Roman, C.T.
2002-01-01
This study evaluates the response of three salt marshes, associated with the Rachel Carson National Wildlife Refuge (Maine), to the practice of ditch plugging. Drainage ditches, originally dug to drain the marsh for mosquito control or to facilitate salt hay farming, are plugged with marsh peat in an effort to impound water upstream of the plug, raise water table levels in the marsh, and increase surface water habitat. At two study sites, Moody Marsh and Granite Point Road Marsh, ditch plugs were installed in spring 2000. Monitoring of hydrology, vegetation, nekton and bird utilization, and marsh development processes was conducted in 1999, before ditch plugging, and then in 2000 and 2001 (all parameters except nekton), after ditch plugging. Each study site had a control marsh that was monitored simultaneously with the plugged marsh, and thus, we employed a BACI study design (before, after, control, impact). A third site, Marshall Point Road Marsh, was plugged in 1998. Monitoring of the plugged and control sites was conducted in 1999 and 2000, with limited monitoring in 2001, thus there was no ?before? plug monitoring. With ditch plugging, water table levels increased toward the marsh surface and the areal extent of standing water increased. Responding to a wetter substrate, a vegetation change from high marsh species (e.g., Spartina patens) to those more tolerant of flooded conditions (e.g., Spartina alterniflora) was noted at two of the three ditch plugged sites. Initial response of the nekton community (fishes and decapod crustaceans) was evaluated by monitoring utilization of salt marsh pools using a 1m2 enclosure trap. In general, nekton species richness, density, and community structure remained unchanged following ditch plugging at the Moody and Granite Point sites. At Marshall Point, species richness and density (number of individuals per m2) were significantly greater in the experimental plugged marsh than the control marsh (<2% of the control marsh was open water habitat vs. 11% of the plugged marsh). The response of birds, categorized as waterfowl & waterbirds, shorebirds & wading birds, gulls & terns, and miscellaneous (raptors, passerines, other), was variable. Following ditch plugging, bird species richness increased at the Granite Point site (1999 pre-plug = 15.4, 2000 post-plug = 26.2, 2001 post-plug = 38.7). Because of a low sample size at Moody Marsh, reliable statements on species richness cannot be made. Density of birds (no. of birds per ha) remained unchanged with ditch plugging at Granite Point Marsh, although there was a strong, but not statistically significant, trend toward increased density. This study only reports on initial responses of marsh functions to ditch plugging. Monitoring should continue at these sites, and perhaps at additional sites, for the next decade or so. A monitoring plan is recommended. Long-term monitoring will include evaluation of salt marsh development processes using SET (surface elevation table) methodology. There is concern, although not confirmed, that as ditch-plugged marshes become wetter and marsh grass production declines their ability to keep pace with sea level rise could be jeopardized. It is suggested that ditch plugging should be considered an experimental marsh management technique. Additional monitoring on the physical and habitat responses of ditch-plugged marshes is required, along with assessments of other techniques aimed at restoring open water habitat to the marsh surface.
Said, Azza Mohamed Ahmed; Farag, Mona Elsayed; Abdulla, Tarek Mohamed; Ziko, Othman Ali Othman; Osman, Wesam Mohamed
2016-01-01
AIM To evaluate the effect of punctal occlusion using thermosensitive (smart plug) versus silicone plug for management of aqueous deficient dry eye on corneal sensitivity, ocular surface health and tear film stability. METHODS A comparative prospective interventional case study included 45 patients with bilateral severe form of aqueous deficient dry eye. In each patient, the smart plug was inserted in the lower punctum of the right eye which was considered as study group 1 and silicone plug was inserted in the lower punctum of the left eye of the same patient which was considered as study group 2. All patients were subjected to careful history taking and questionnaire for subjective assessment of severity of symptoms. Corneal sensitivity, corneal fluorescein, rose bengal staining, Schirmer's I test, tear film break up time and conjunctival impression cytology were performed pre and 1, 3 and 6mo post plug insertion. RESULTS A statistically significant improvement in subjective and objective manifestations occurred following treatment with both types of plugs (P<0.01). The thermosensitive plug caused significant overall improvement, decrease in frequency of application of tear substitutes and improvement of conjunctival impression cytology parameters in the inserted side (P<0.01). Canaliculitis was reported in two eyes (4.4%) following punctal occlusion using thermosensitive plug (study group 1). Spontaneous plug loss occurred in 21 eyes (46.6%) in the silicone plug group (study group 2). CONCLUSION Improvement of subjective and objective manifestations of aqueous deficient dry eye occurs following punctal plug occlusion. Thermosensitive plug has good patient's compliance with fewer complications and lower rates of loss compared to the silicone plug. PMID:27990362
Experimental study of moving throat plug in a shock tunnel
NASA Astrophysics Data System (ADS)
Lee, J. K.; Park, C.; Kwon, O. J.
2015-07-01
An experimental study has been carried out to investigate the flow in the KAIST shock tunnel with two moving throat plugs at a primary shock velocity of 1.19 km/s. The nozzle reservoir pressure and the Pitot pressure at the exit of the nozzle were measured to examine the influence of the moving throat plugs on the shock tunnel flow. To assess the present experimental results, comparisons with previous work using a stationary throat plug were made. The mechanism for closing the moving throat plug was developed and verified. The source of the force to move the plug was the pressure generated when the primary shock was reflected at the bottom of the plug. It was observed that the two plugs terminated the shock tunnel flow after the steady flow. .The time for the plugs to terminate the flow showed good agreement with the calculation of the proposed simple analytic solution. There was a negligible difference in flow values such as the reflected pressure and the Pitot pressure between the moving and the stationary plugs.
Vascular plugs - A key companion to Interventionists - 'Just Plug it'.
Ramakrishnan, Sivasubramanian
2015-01-01
Vascular plugs are ideally suited to close extra-cardiac, high flowing vascular communications. The family of vascular plugs has expanded. Vascular plugs in general have a lower profile and the newer variants can be delivered even through a diagnostic catheter. These features make them versatile and easy to use. The Amplatzer vascular plugs are also used for closing intracardiac defects including coronary arterio-venous fistula and paravalvular leakage in an off-label fashion. In this review, the features of currently available vascular plugs are reviewed along with tips and tricks of using them in the cardiac catheterization laboratory. Copyright © 2015. Published by Elsevier B.V.
Biggins, Dean E.; Ramakrishnan, Shantini; Goldberg, Amanda R.; Eads, David A.
2012-01-01
Black-tailed prairie dogs (Cynomys ludovicianus) plug burrows occupied by black-footed ferrets (Mustela nigripes), and they also plug burrows to entomb dead prairie dogs. We further evaluated these phenomena by sampling connectivity and plugging of burrow openings on prairie dog colonies occupied by ferrets, colonies where recreational shooting was allowed, and colonies with neither shooting nor ferrets. We counted burrow openings on line surveys and within plots, classified surface plugging, and used an air blower to examine subsurface connectivity. Colonies with ferrets had lower densities of openings, fewer connected openings (suggesting increased subsurface plugging), and more surface plugs compared to colonies with no known ferrets. Colonies with recreational shooting had the lowest densities of burrow openings, and line-survey data suggested colonies with shooting had intermediate rates of surface plugging. The extent of surface and subsurface plugging could have consequences for the prairie dog community by changing air circulation and escape routes of burrow systems and by altering energetic relationships. Burrow plugging might reduce prairie dogs' risk of predation by ferrets while increasing risk of predation by American badgers (Taxidea taxus); however, the complexity of the trade-off is increased if plugging increases the risk of predation on ferrets by badgers. Prairie dogs expend more energy plugging and digging when ferrets or shooting are present, and ferrets increase their energy expenditures when they dig to remove those plugs. Microclimatic differences in plugged burrow systems may play a role in flea ecology and persistence of the flea-borne bacterium that causes plague (Yersinia pestis).
Friction Pull Plug and Material Configuration for Anti-Chatter Friction Pull Plug Weld
NASA Technical Reports Server (NTRS)
Littell, Justin Anderson (Inventor)
2016-01-01
A friction pull plug is provided for use in forming a plug weld in a hole in a material. The friction pull plug includes a shank and a series of three frustoconical sections. The relative sizes of the sections assure that a central one of the sections defines the initial contact point between the hole's sides. The angle defined by the central one of the sections reduces or eliminates chatter as the plug is pulled into the hole.
Odyne Plug-In Hybrid Electric Utility Truck Testing | Transportation
Research | NREL Odyne Plug-In Hybrid Electric Utility Truck Evaluation Odyne Plug-In Hybrid data on plug-in hybrid electric utility trucks operated by a variety of companies. Photo courtesy of Odyne, NREL NREL is evaluating the in-service performance of about 120 plug-in hybrid electric utility
Numerical Simulation of Sediment Plug Formation in Alluvial Channels
NASA Astrophysics Data System (ADS)
Posner, A. J.; Duan, J. G.
2011-12-01
A sediment plug is the aggregation of sediment in a river reach that completely blocks the original channel resulting in plug growth upstream by accretion and flooding in surrounding areas. Sediment plugs historically form over relatively short periods, in many cases a matter of weeks. Although sediment plugs are much more common in reach constrictions associated with large woody debris, the mouths of tributaries, and along coastal regions, this investigation focuses on sediment plug formation in an alluvial river. During high flows in the years 1991, 1995, 2005, and 2008, a sediment plug formed in the San Marcial reach of the Middle Rio Grande. The Bureau of Reclamation has had to spend millions of dollars dredging the channel to restore flows to Elephant Butte Reservoir. The hydrodynamic and sediment transport processes, associated with plug formation, occurring in this reach are driven by 1) a flow constriction associated with a rock outcrop, 2) a railroad bridge, and 3) the water level of the downstream reservoir. The three-dimensional hydrodynamic model, Delft3D, was implemented to determine the hydrodynamic and sediment transport parameters and variables required to simulate plug formation in an effort to identify hydro- and morphodynamic thresholds. Several variables were identified by previous studies as metrics for plug formation. These variables were used in our investigation to detect the relative magnitude of each process. Both duration and degree of high flow events were simulated, along with extent of cohesive sediment deposits, reservoir level, and percent of fines in suspended sediment distribution. Results of this analysis illustrate that this model is able to reproduce the sediment plug formation. Model calibration was based on measured water levels and changes in bathymetry using both sediment transport and morphologic change parameters. Changes to hydraulic and sediment parameters are not proportional to morphologic changes and are asymptotic in their response. These results suggest that there are thresholds to predict plug formation and that the contribution of specific variables to plug formation is not uniform. Sediment plug formation is a costly and dangerous phenomenon, especially in large alluvial rivers. This investigation yielded specific insights into the hydrodynamic and morphologic processes occurring during sediment plug formation. These insights can be used to reduce the risk of plug formation and predict the locations and times of other sediment plugs.
Eddy Current Minimizing Flow Plug for Use in Flow Conditioning and Flow Metering
NASA Technical Reports Server (NTRS)
England, John Dwight (Inventor); Kelley, Anthony R. (Inventor)
2015-01-01
An eddy-current-minimizing flow plug has open flow channels formed between the plug's inlet and outlet. Each open flow channel includes (i) a first portion that originates at the inlet face and converges to a location within the plug that is downstream of the inlet, and (ii) a second portion that originates within the plug and diverges to the outlet. The diverging second portion is approximately twice the length of the converging first portion. The plug is devoid of planar surface regions at its inlet and outlet, and in fluid flow planes of the plug that are perpendicular to the given direction of a fluid flowing therethrough.
Protection Against Hearing Loss in General Aviation Operations, Phase II
NASA Technical Reports Server (NTRS)
Parker, J. F., Jr.
1972-01-01
An inflight evaluation of four aural protectors is presented. The hearing protection devices studied were ear muffs, plastic ear plugs, rubber ear plugs, and wax ear plugs. It is concluded that ear plugs are satisfactory for providing adequate sound attenuation in general aviation aircraft. However, two problems were found in the use of ear plugs; comfort and interference with cabin communications.
Whealton, John H.; Tsai, Chin-Chi
2003-05-27
A spark plug device includes a structure for modification of an arc, the modification including arc rotation. The spark plug can be used in a combustion engine to reduce emissions and/or improve fuel economy. A method for operating a spark plug and a combustion engine having the spark plug device includes the step of modifying an arc, the modifying including rotating the arc.
Hydrological responses to channelization and the formation of valley plugs and shoals
Pierce, Aaron R.; King, Sammy L.
2017-01-01
Rehabilitation of floodplain systems focuses on restoring interactions between the fluvial system and floodplain, however, there is a paucity of information on the effects of valley plugs and shoals on floodplain hydrological processes. We investigated hydrologic regimes in floodplains at three valley plug sites, two shoal sites, and three unchannelized sites. Valley plug sites had altered surface and sub-surface hydrology relative to unchannelized sites, while only sub-surface hydrology was affected at shoal sites. Some of the changes were unexpected, such as reduced flood duration and flood depth in floodplains associated with valley plugs. Our results emphasize the variability associated with hydrologic processes around valley plugs and our rudimentary understanding of the effects associated with these geomorphic features. Water table levels were lower at valley plug sites compared to unchannelized sites, however, valley plug sites had a greater proportion of days when water table inundation was above mean root collar depth than both shoal and unchannelized sites as a result of lower root collar depths and higher deposition rates. This study has provided evidence that valley plugs can affect both surface and sub-surface hydrology in different ways than previously thought and illustrates the variability in hydrological responses to valley plug formation.
NASA Technical Reports Server (NTRS)
Ruf, J. H.; Hagemann, G.; Immich, H.
2003-01-01
A three dimensional linear plug nozzle of area ratio 12.79 was designed by EADS Space Transportation (former Astrium Space Infrastructure). The nozzle was tested within the German National Technology Program 'LION' in a cold air wind tunnel by TU Dresden. The experimental hardware and test conditions are described. Experimental data was obtained for the nozzle without plug side wall fences at a nozzle pressure ratio of 116 and then with plug side wall fences at NPR 110. Schlieren images were recorded and axial profiles of plug wall static pressures were measured at several spanwise locations and on the plug base. Detailed CFD analysis was performed for these nozzle configurations at NPR 116 by NASA MSFC. The CFD exhibits good agreement with the experimental data. A detailed comparison of the CFD results and the experimental plug wall pressure data are given. Comparisons are made for both the without and with plug side wall fence configurations. Numerical results for density gradient are compared to experimental Schlieren images. Experimental nozzle thrust efficiencies are calculated based on the CFD results. The CFD results are used to illustrate the plug nozzle fluid dynamics. The effect of the plug side wall is emphasized.
Initial Study of Friction Pull Plug Welding
NASA Technical Reports Server (NTRS)
Rich, Brian S.
1999-01-01
Pull plug friction welding is a new process being developed to conveniently eliminate defects from welded plate tank structures. The general idea is to drill a hole of precise, optimized dimensions and weld a plug into it, filling the hole perfectly. A conically-shaped plug is rotated at high angular velocity as it is brought into contact with the plate material in the hole. As the plug is pulled into the hole, friction rapidly raises the temperature to the point at which the plate material flows plastically. After a brief heating phase, the plug rotation is terminated. The plug is then pulled upon with a forging force, solidly welding the plug into the hole in the plate. Three aspects of this process were addressed in this study. The transient temperature distribution was analyzed based on slightly idealized boundary conditions for different plug geometries. Variations in hole geometry and ram speed were considered, and a program was created to calculate volumes of displaced material and empty space, as well as many other relevant dimensions. The relation between the axially applied forging force and the actual forging pressure between the plate and plug surfaces was determined for various configurations.
Lin, Tung-Liang; Sheen, Huey-Min; Chung, Chin-Teng; Yang, Sai-Wei; Lin, Shih-Yi; Luo, Hong-Ji; Chen, Chung-Yu; Chan, I-Cheng; Shih, Hsu-Sheng; Sheu, Wayne Huey-Herng
2013-07-29
Removable plug insoles appear to be beneficial for patients with diabetic neuropathic feet to offload local plantar pressure. However, quantitative evidence of pressure reduction by means of plug removal is limited. The value of additional insole accessories, such as arch additions, has not been tested. The purpose of this study was to evaluate the effect of removing plugs from foam based insoles, and subsequently adding extra arch support, on plantar pressures. In-shoe plantar pressure measurements were performed on 26 patients with diabetic neuropathic feet at a baseline condition, in order to identify the forefoot region with the highest mean peak pressure (MPP). This was defined as the region of interest (ROI) for plug removal.The primary outcome was measurement of MPP using the pedar® system in the baseline and another three insole conditions (pre-plug removal, post-plug removal, and post-plug removal plus arch support). Among the 26 ROIs, a significant reduction in MPP (32.3%, P<0.001) was found after removing the insole plugs. With an arch support added, the pressure was further reduced (9.5%, P<0.001). There were no significant differences in MPP at non-ROIs between pre- and post-plug removal conditions. These findings suggest that forefoot plantar pressure can be reduced by removing plugs and adding arch support to foam-based insoles. This style of insole may therefore be clinically useful in managing patients with diabetic peripheral neuropathy.
Song, Helen; Li, Hung-Wing; Munson, Matthew S.; Van Ha, Thuong G.; Ismagilov, Rustem F.
2006-01-01
This paper describes extending plug-based microfluidics to handling complex biological fluids such as blood, solving the problem of injecting additional reagents into plugs, and applying this system to measuring of clotting time in small volumes of whole blood and plasma. Plugs are droplets transported through microchannels by fluorocarbon fluids. A plug-based microfluidic system was developed to titrate an anticoagulant (argatroban) into blood samples and to measure the clotting time using the activated partial thromboplastin time (APTT) test. To carry out these experiments, the following techniques were developed for a plug-based system: (i) using Teflon AF coating on the microchannel wall to enable formation of plugs containing blood and transport of the solid fibrin clots within plugs, (ii) using a hydrophilic glass capillary to enable reliable merging of a reagent from an aqueous stream into plugs, (iii) using bright-field microscopy to detect the formation of a fibrin clot within plugs and using fluorescent microscopy to detect the production of thrombin using a fluorogenic substrate, and (iv) titration of argatroban (0–1.5 μg/mL) into plugs and measurement of the resulting APTTs at room temperature (23 °C) and physiological temperature (37 °C). APTT measurements were conducted with normal pooled plasma (platelet-poor plasma) and with donor’s blood samples (both whole blood and platelet-rich plasma). APTT values and APTT ratios measured by the plug-based microfluidic device were compared to the results from a clinical laboratory at 37 °C. APTT obtained from the on-chip assay were about double those from the clinical laboratory but the APTT ratios from these two methods agreed well with each other. PMID:16841902
Biomass plug development and propagation in porous media.
Stewart, T L; Fogler, H S
2001-02-05
Exopolymer-producing bacteria can be used to modify soil profiles for enhanced oil recovery or bioremediation. Understanding the mechanisms associated with biomass plug development and propagation is needed for successful application of this technology. These mechanisms were determined from packed-bed and micromodel experiments that simulate plugging in porous media. Leuconostoc mesenteroides was used, because production of dextran, a water-insoluble exopolymer, can be controlled by using different carbon sources. As dextran was produced, the pressure drop across the porous media increased and began to oscillate. Three pressure phases were identified under exopolymer-producing conditions: the exopolymer-induction phase, the plugging phase, and the plug-propagation phase. The exopolymer-induction phase extended from the time that exopolymer-producing conditions were induced until there was a measurable increase in pressure drop across the porous media. The plugging phase extended from the first increase in pressure drop until a maximum pressure drop was reached. Changes in pressure drop in these two phases were directly related to biomass distribution. Specifically, flow channels within the porous media filled with biomass creating a plugged region where convective flow occurred only in water channels within the biofilm. These water channels were more restrictive to flow causing the pressure drop to increase. At a maximum pressure drop across the porous media, the biomass yielded much like a Bingham plastic, and a flow channel was formed. This behavior marked the onset of the plug-propagation phase which was characterized by sequential development and breakthrough of biomass plugs. This development and breakthrough propagated the biomass plug in the direction of nutrient flow. The dominant mechanism associated with all three phases of plugging in porous media was exopolymer production; yield stress is an additional mechanism in the plug-propagation phase. Copyright 2001 John Wiley & Sons, Inc.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-04-02
... phasing inspections and magnetic plug inspections for metal particles on the drain plug using detailed... inspections and magnetic plug inspections for metal particles on the drain plug using detailed inspection..., but the magnetic plug inspection reveals metal particles with dimensions greater than 1.5 mm (0.059 in...
40 CFR 144.63 - Financial assurance for plugging and abandonment.
Code of Federal Regulations, 2010 CFR
2010-07-01
... current plugging and abandonment cost estimate, except as provided in § 144.70(g), divided by the number... days after receiving bills for plugging and abandonment activities, the Regional Administrator will... abandonment activities, the Regional Administrator will determine whether the plugging and abandonment...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Feder, Russell; Youssef, Mahamoud; Klabacha, Jonathan
USITER is one of seven partner domestic agencies (DA) contributing components to the ITER project. Four diagnostic port plug packages (two equatorial ports and two upper ports) will be engineered and fabricated by Princeton Plasma Physics Lab (PPPL). Diagnostic port plugs as illustrated in Fig. 1 are large primarily stainless steel structures that serve several roles on ITER. The port plugs are the primary vacuum seal and tritium confinement barriers for the vessel. The port plugs also house several plasma diagnostic systems and other machine service equipment. Finally, each port plug must shield high energy neutrons and gamma photons frommore » escaping and creating radiological problems in maintenance areas behind the port plugs. The optimization of the balance between adequate shielding and the need for high performance, high throughput diagnostics systems is the focus of this paper. Neutronics calculations are also needed for assessing nuclear heating and nuclear damage in the port plug and diagnostic components. Attila, the commercially available discrete-ordinates software package, is used for all diagnostic port plug neutronics analysis studies at PPPL.« less
Marcet, Marcus M; Shtein, Roni M; Bradley, Elizabeth A; Deng, Sophie X; Meyer, Dale R; Bilyk, Jurij R; Yen, Michael T; Lee, W Barry; Mawn, Louise A
2015-08-01
To review the published literature assessing the efficacy and safety of lacrimal drainage system plug insertion for dry eye in adults. Literature searches of the PubMed and Cochrane Library databases were last conducted on March 9, 2015, without date restrictions and were limited to English language abstracts. The searches retrieved 309 unique citations. The primary authors reviewed the titles and abstracts. Inclusion criteria specified reports that provided original data on plugs for the treatment of dry eyes in at least 25 patients. Fifty-three studies of potential relevance were assigned to full-text review. The 27 studies that met the inclusion criteria underwent data abstraction by the panels. Abstracted data included study characteristics, patient characteristics, plug type, insertion technique, treatment response, and safety information. All studies were observational and rated by a methodologist as level II or III evidence. The plugs included punctal, intracanalicular, and dissolving types. Fifteen studies reported metrics of improvement in dry eye symptoms, ocular-surface status, artificial tear use, contact lens comfort, and tear break-up time. Twenty-five studies included safety data. Plug placement resulted in ≥50% improvement of symptoms, improvement in ocular-surface health, reduction in artificial tear use, and improved contact lens comfort in patients with dry eye. Serious complications from plugs were infrequent. Plug loss was the most commonly reported problem with punctal plugs, occurring on average in 40% of patients. Overall, among all plug types, approximately 9% of patients experienced epiphora and 10% required removal because of irritation from the plugs. Canaliculitis was the most commonly reported problem for intracanalicular plugs and occurred in approximately 8% of patients. Other complications were reported in less than 4% of patients on average and included tearing, discomfort, pyogenic granuloma, and dacryocystitis. On the basis of level II and III evidence in these studies, plugs improve the signs and symptoms of moderate dry eye that are not improved with topical lubrication, and they are well tolerated. There are no level I studies that describe the efficacy or safety of lacrimal drainage system plugs. Copyright © 2015 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.
2009-07-16
Frequency (MHz) Figure 3.4: CABLE SMA/SMA 24" RG-316DS. CABLE SMA PLUG-PLUG HF -.086 8" 3.1. TRANSMITTER IMPLEMENTATION 13 Length: 8.0" (203.2mm) Color...Gray RG Type: Hand Formable .086 Connector: Type SMA Male to SMA Male Features: Shielded "• JI Figure 3.5: CABLE SMA PLUG-PLUG HF -.086 8...34 . • CABLE SMA PLUG-PLUG HF -.141 8" Length: 8.0" (203.2mm) Color: Gray RG Type: Hand Formable .141 14 CHAPTER 3. 2 BY I MISO SYSTEM DEVELOPMENT
Hot cell shield plug extraction apparatus
Knapp, Philip A.; Manhart, Larry K.
1995-01-01
An apparatus is provided for moving shielding plugs into and out of holes in concrete shielding walls in hot cells for handling radioactive materials without the use of external moving equipment. The apparatus provides a means whereby a shield plug is extracted from its hole and then swung approximately 90 degrees out of the way so that the hole may be accessed. The apparatus uses hinges to slide the plug in and out and to rotate it out of the way, the hinge apparatus also supporting the weight of the plug in all positions, with the load of the plug being transferred to a vertical wall by means of a bolting arrangement.
3D CFD Simulation of Plug Dynamics and Splitting through a Bifurcating Airway Model
NASA Astrophysics Data System (ADS)
Hoi, Cory; Raessi, Mehdi
2017-11-01
Respiratory distress syndrome (RDS) occurs because of pulmonary surfactant insufficiency in the lungs of preterm infants. The common medical procedure to treat RDS, called surfactant respiratory therapy (SRT), involves instilling liquid surfactant plugs into the pulmonary airways. SRT's effectiveness highly depends on the ability to deliver surfactant through the complex branching airway network. Experimental and computational efforts have been made to understand complex fluid dynamics of liquid plug motion through the lung airways in order to increase SRT's response rate. However, previous computational work used 2D airway model geometries and studied plug dynamics of a pre-split plug. In this work, we present CFD simulations of surfactant plug motion through a 3D bifurcating airway model. In our 3D y-tube geometry representing the lung airways, we are not limited by 2D or pre-split plug assumptions. The airway walls are covered with a pre-existing liquid film. Using a passive scalar marking the surfactant plug, the plug splitting and surfactant film deposition is studied under various airway orientations. Exploring the splitting process and liquid distribution in a 3D geometry will advance our understanding of surfactant delivery and will increase the effectiveness of SRT.
Effects of Proud Large Osteochondral Plugs on Contact Forces and Knee Kinematics: A Robotic Study.
Du, Peter Z; Markolf, Keith L; Boguszewski, Daniel V; Yamaguchi, Kent T; Lama, Christopher J; McAllister, David R; Jones, Kristofer J
2018-05-01
Osteochondral allograft (OCA) transplantation is used to treat large focal femoral condylar articular cartilage defects. A proud plug could affect graft survival by altering contact forces (CFs) and knee kinematics. A proud OCA plug will significantly increase CF and significantly alter knee kinematics throughout controlled knee flexion. Controlled laboratory study. Human cadaver knees had miniature load cells, each with a 20-mm-diameter cylinder of native bone/cartilage attached at its exact anatomic position, installed in both femoral condyles at standardized locations representative of clinical defects. Spacers were inserted to create proud plug conditions of +0.5, +1.0, and +1.5 mm. CFs and knee kinematics were recorded as a robot flexed the knee continuously from 0° to 50° under 1000 N of tibiofemoral compression. CFs were increased significantly (vs flush) for all proudness conditions between 0° and 45° of flexion (medial) and 0° to 50° of flexion (lateral). At 20°, the average increases in medial CF for +0.5-mm, +1-mm, and +1.5-mm proudness were +80 N (+36%), +155 N (+70%), and +193 N (+87%), respectively. Corresponding increases with proud lateral plugs were +44 N (+14%), +90 N (+29%), and +118 N (+38%). CF increases for medial plugs at 20° of flexion were significantly greater than those for lateral plugs at all proudness conditions. At 50°, a 1-mm proud lateral plug significantly decreased internal tibial rotation by 15.4° and decreased valgus rotation by 2.5°. A proud medial or lateral plug significantly increased CF between 0° and 45° of flexion. Our results suggest that a medial plug at 20° may be more sensitive to graft incongruity than a lateral plug. The changes in rotational kinematics with proud lateral plugs were attributed to earlier contact between the proud plug's surface and the lateral meniscus, leading to rim impingement with decreased tibial rotation. Increased CF and altered knee kinematics from a proud femoral plug could affect graft viability. Plug proudness of only 0.5 mm produced significant changes in CF and knee kinematics, and the clinically accepted 1-mm tolerance may need to be reexamined in view of our findings.
Aeroacoustics of contoured and solid/porous conical plug-nozzle supersonic jet flows
NASA Technical Reports Server (NTRS)
Dosanjh, D. S.; Das, I. S.
1985-01-01
The acoustic far field, the shock-associated noise and characteristics of the repetitive shock structure of supersonic jet flows issuing from a contoured plug-nozzle and uncontoured plug-nozzle having a short conical plug of either a solid or a combination of solid/porous surface with pointed termination operated at a range of supercritical pressure are reported. The contoured and the uncontoured plug-nozzles had the same throat area and the same annular-radius ratio.
An objective comparison of leakage between commonly used earplugs.
Alt, Jeremiah A; Collins, William O
2012-01-01
We sought to determine the efficacy of commonly used earplugs using an anatomically correct ear model. The total volume and rate of water that leaked past the earplug and subsequent defect in the tympanic membrane over separately measured 30, 60, 120, and 180-second intervals were recorded. Scenarios tested included a control with no earplug, custom molded earplug (Precision Laboratories, Orlando, FL), Mack's plug (Warren, MI), Doc's plug (Santa Cruz, CA), and cotton balls coated with petroleum jelly. All plugs tested resulted in less leakage at all time points when compared with no plug (P < .05). At 30 seconds, the custom molded, Mack's and Doc's plugs all showed significantly less leakage when compared with the cotton ball coated with petroleum jelly (P < .05). At 60, 120, and 180 seconds, Mack's, Doc's, and the cotton plugs all showed significantly less leakage compared with the customized plug (P < .05). At 120 and 180 seconds, Mack's plugs had significant less leakage than the cotton plug (P < .05). Among the types of plugs, the molded variety (Mack's) showed the least volume and lowest leakage rate (f(4,45) = 94 [P < .001]). In addition, Doc's and cotton balls coated with petroleum jelly were more effective than the customized earplugs. If the clinician feels that middle ear and external canal water exposure should be minimized, then use of earplugs, particularly the moldable variety, merits further consideration. Copyright © 2012 Elsevier Inc. All rights reserved.
Electrostatic networks control plug stabilization in the PapC usher.
Pham, Thieng; Henderson, Nadine S; Werneburg, Glenn T; Thanassi, David G; Delcour, Anne H
2015-01-01
The PapC usher, a β-barrel pore in the outer membrane of uropathogenic Escherichia coli, is used for assembly of the P pilus, a key virulence factor in bacterial colonization of human kidney cells. Each PapC protein is composed of a 24-stranded β-barrel channel, flanked by N- and C-terminal globular domains protruding into the periplasm, and occluded by a plug domain (PD). The PD is displaced from the channel towards the periplasm during pilus biogenesis, but the molecular mechanism for PD displacement remains unclear. Two structural features within the β-barrel, an α-helix and β5-6 hairpin loop, may play roles in controlling plug stabilization. Here we have tested clusters of residues at the interface of the plug, barrel, α-helix and hairpin, which participate in electrostatic networks. To assess the roles of these residues in plug stabilization, we used patch-clamp electrophysiology to compare the activity of wild-type and mutant PapC channels containing alanine substitutions at these sites. Mutations interrupting each of two salt bridge networks were relatively ineffective in disrupting plug stabilization. However, mutation of two pairs of arginines located at the inner and the outer surfaces of the PD resulted in an enhanced propensity for plug displacement. One arginine pair involved in a repulsive interaction between the linkers that tether the plug to the β-barrel was particularly sensitive to mutation. These results suggest that plug displacement, which is necessary for pilus assembly and translocation, may require a weakening of key electrostatic interactions between the plug linkers, and the plug and the α-helix.
Adamson, David N; Mustafi, Debarshi; Zhang, John X J; Zheng, Bo; Ismagilov, Rustem F
2006-09-01
This paper reports a method for the production of arrays of nanolitre plugs with distinct chemical compositions. One of the primary constraints on the use of plug-based microfluidics for large scale biological screening is the difficulty of fabricating arrays of chemically distinct plugs on the nanolitre scale. Here, using microfluidic devices with several T-junctions linked in series, a single input array of large (approximately 320 nL) plugs was split to produce 16 output arrays of smaller (approximately 20 nL) plugs; the composition and configuration of these arrays were identical to that of the input. This paper shows how the passive break-up of plugs in T-junction microchannel geometries can be used to produce a set of smaller-volume output arrays useful for chemical screening from a single large-volume array. A simple theoretical description is presented to describe splitting as a function of the Capillary number, the capillary pressure, the total pressure difference across the channel, and the geometric fluidic resistance. By accounting for these considerations, plug coalescence and plug-plug contamination can be eliminated from the splitting process and the symmetry of splitting can be preserved. Furthermore, single-outlet splitting devices were implemented with both valve- and volume-based methods for coordinating the release of output arrays. Arrays of plugs containing commercial sparse matrix screens were obtained from the presented splitting method and these arrays were used in protein crystallization trials. The techniques presented in this paper may facilitate the implementation of high-throughput chemical and biological screening.
Alternative Fuels Data Center: Developing Infrastructure to Charge Plug-In
Electric Vehicles Developing Infrastructure to Charge Plug-In Electric Vehicles to someone by E -mail Share Alternative Fuels Data Center: Developing Infrastructure to Charge Plug-In Electric Vehicles on Facebook Tweet about Alternative Fuels Data Center: Developing Infrastructure to Charge Plug-In
40 CFR 146.92 - Injection well plugging.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 24 2012-07-01 2012-07-01 false Injection well plugging. 146.92... to Class VI Wells § 146.92 Injection well plugging. (a) Prior to the well plugging, the owner or operator must flush each Class VI injection well with a buffer fluid, determine bottomhole reservoir...
40 CFR 144.62 - Cost estimate for plugging and abandonment.
Code of Federal Regulations, 2011 CFR
2011-07-01
... must revise the plugging and abandonment cost estimate whenever a change in the plugging and... 40 Protection of Environment 23 2011-07-01 2011-07-01 false Cost estimate for plugging and abandonment. 144.62 Section 144.62 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) WATER...
NASA Technical Reports Server (NTRS)
Mcconnaughey, P. K.; Garcia, R.; Dejong, F. J.; Sabnis, J. S.; Pribik, D. A.
1989-01-01
An analysis of Space Shuttle Main Engine high-pressure oxygen turbopump nozzle plug trajectories has been performed, using a Lagrangian method to track nozzle plug particles expelled from a turbine through a high Reynolds number flow in a turnaround duct with turning vanes. Axisymmetric and parametric analyses reveal that if nozzle plugs exited the turbine they would probably impact the LOX heat exchanger with impact velocities which are significantly less than the penetration velocity. The finding that only slight to moderate damage will result from nozzle plug failure in flight is supported by the results of a hot-fire engine test with induced nozzle plug failures.
Burner rig study of variables involved in hole plugging of air cooled turbine engine vanes
NASA Technical Reports Server (NTRS)
Deadmore, D. L.; Lowell, C. E.
1983-01-01
The effects of combustion gas composition, flame temperatures, and cooling air mass flow on the plugging of film cooling holes by a Ca-Fe-P-containing deposit were investigated. The testing was performed on film-cooled vanes exposed to the combustion gases of an atmospheric Mach 0.3 burner rig. The extent of plugging was determined by measurement of the open hole area at the conclusion of the tests as well as continuous monitoring of some of the tests using stop-action photography. In general, as the P content increased, plugging rates also increased. The plugging was reduced by increasing flame temperature and cooling air mass flow rates. At times up to approximately 2 hours little plugging was observed. This apparent incubation period was followed by rapid plugging, reaching in several hours a maximum closure whose value depended on the conditions of the test.
ERIC Educational Resources Information Center
Thompson, Douglas E.
2013-01-01
In today's complex music software packages, many features can remain unexplored and unused. Software plug-ins--available in most every music software package, yet easily overlooked in the software's basic operations--are one such feature. In this article, I introduce readers to plug-ins and offer tips for purchasing plug-ins I have…
40 CFR 144.62 - Cost estimate for plugging and abandonment.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 22 2010-07-01 2010-07-01 false Cost estimate for plugging and... Waste Injection Wells § 144.62 Cost estimate for plugging and abandonment. (a) The owner or operator must prepare a written estimate, in current dollars, of the cost of plugging the injection well in...
Steady propagation of Bingham plugs in 2D channels
NASA Astrophysics Data System (ADS)
Zamankhan, Parsa; Takayama, Shuichi; Grotberg, James
2009-11-01
The displacement of the yield-stress liquid plugs in channels and tubes occur in many biological systems and industrial processes. Among them is the propagation of mucus plugs in the respiratory tracts as may occur in asthma, cystic fibrosis, or emphysema. In this work the steady propagation of mucus plugs in a 2D channel is studied numerically, assuming that the mucus is a pure Bingham fluid. The governing equations are solved by a mixed-discontinuous finite element formulation and the free surface is resolved with the method of spines. The constitutive equation for a pure Bingham fluid is modeled by a regularization method. Fluid inertia is neglected, so the controlling parameters in a steady displacement are; the capillary number, Ca, Bingham number ,Bn, and the plug length. According to the numerical results, the yield stress behavior of the plug modifies the plug shape, the pattern of the streamlines and the distribution of stresses in the plug domain and along the walls in a significant way. The distribution along the walls is a major factor in studying cell injuries. This work is supported through the grant NIH HL84370.
Portal vein embolization with plug/coils improves hepatectomy outcome.
Malinowski, Maciej; Geisel, Dominik; Stary, Victoria; Denecke, Timm; Seehofer, Daniel; Jara, Maximillian; Baron, Annekathrin; Pratschke, Johann; Gebauer, Bernhard; Stockmann, Martin
2015-03-01
Portal vein embolization (PVE) has become the standard of care before extended hepatectomy. Various PVE methods using different embolization materials have been described. In this study, we compared PVE with polyvinyl alcohol particles alone (PVA only) versus PVA with plug or coils (PVA + plug/coils). Patients undergoing PVE before hepatectomy were included. PVA alone was used until December 2013, thereafter plug or coils were placed in addition. The volume of left lateral liver lobe (LLL), clinical parameters, and liver function tests were measured before PVE and resection. A total of 43 patients were recruited into the PVA only group and 42 were recruited into the PVA + plug/coils group. There were no major differences between groups except significantly higher total bilirubin level before PVE in the PVA only group, which improved before hepatectomy. Mean LLL volume increased by 25.7% after PVE in the PVA only group and by 44% in the PVA + plug/coils group (P < 0.001). Recanalization was significantly less common in the PVA + plug/coils group. In multivariate regression, initial LLL volume and use of plug or coils were the only parameters influencing LLL volume increase. The postoperative liver failure rate was significantly reduced in PVA + plug/coils group (P = <0.001). PVE using PVA particles together with plug or coils is a safe and efficient method to increase future liver remnant volume. The additional central embolization with plug or coils led to an increased hypertrophy, due to lower recanalization rates, and subsequently decreased incidence of postoperative liver failure. No additional procedure-specific complications were observed in this series. Copyright © 2015 Elsevier Inc. All rights reserved.
Alternative Fuels Data Center: Charging Plug-In Electric Vehicles in Public
in Public to someone by E-mail Share Alternative Fuels Data Center: Charging Plug-In Electric Vehicles in Public on Facebook Tweet about Alternative Fuels Data Center: Charging Plug-In Electric Vehicles in Public on Twitter Bookmark Alternative Fuels Data Center: Charging Plug-In Electric Vehicles in
Plug-In Hybrid Electric Vehicle Basics | NREL
Plug-In Hybrid Electric Vehicle Basics Plug-In Hybrid Electric Vehicle Basics Imagine being able to one that's in a standard hybrid electric vehicle. The larger battery pack allows plug-in hybrids to fuel from its onboard tank, and this provides a driving range (the distance a vehicle can travel
Alternative Fuels Data Center: Maintenance and Safety of Hybrid and Plug-In
Electric Vehicles Maintenance and Safety of Hybrid and Plug-In Electric Vehicles to someone by E-mail Share Alternative Fuels Data Center: Maintenance and Safety of Hybrid and Plug-In Electric Vehicles on Facebook Tweet about Alternative Fuels Data Center: Maintenance and Safety of Hybrid and Plug
Unbalanced-flow, fluid-mixing plug with metering capabilities
NASA Technical Reports Server (NTRS)
England, John Dwight (Inventor); Kelley, Anthony R. (Inventor); Van Buskirk, Paul D. (Inventor)
2009-01-01
A fluid mixer plug has holes formed therethrough such that a remaining portion is closed to fluid flow. The plug's inlet face defines a central circuit region and a ring-shaped region with the ring-shaped region including at least some of the plug's remaining portion so-closed to fluid flow. This remaining portion or closed region at each radius R of the ring shaped region satisfies a radius independent, flow-based relationship. Entry openings are defined in the plug's inlet face in correspondence with the holes. The entry openings define an open flow area at each radius of the ring-shaped region. The open flow area at each such radius satisfies the inverse of the flow-based relationship defining the closed regions of the plug.
A Report on Superfluid Helium Flow Through Porous Plugs for Space Science Applications
NASA Technical Reports Server (NTRS)
Mason, F. C.
1983-01-01
As a background for the study of the nature of superfluid helium flow through porous plugs for other space science uses, preliminary tests on various plugs of a given material, diameter, height, and filtration grade have been performed. Two characteristics of the plugs, pore size and number of channels, have been determined by the bubble test and warm flow test of helium gas through the plugs, respectively. Tests on the flow of He II through the plugs have also been performed. An obvious feature of the results of these tests is that for isothermal measurements of pressure versus mass flow rate below approximately 2.10 K, the flow is separated into two different regimes, indicative of the occurrence of a critical phenomenon.
Design and force analysis of end-effector for plug seedling transplanter.
Jiang, Zhuohua; Hu, Yang; Jiang, Huanyu; Tong, Junhua
2017-01-01
Automatic transplanters have been very important in greenhouses since the popularization of seedling nurseries. End-effector development is a key technology for transplanting plug seedlings. Most existing end-effectors have problems with holding root plugs or releasing plugs. An efficient end-effector driven by a linear pneumatic cylinder was designed in this study, which could hold root plugs firmly and release plugs easily. This end-effector with four needles could clamp the plug simultaneously while the needles penetrate into the substrate. The depth and verticality of the needles could be adjusted conveniently for different seedling trays. The effectiveness of this end-effector was tested by a combinational trial examining three seedling nursery factors (the moisture content of the substrate, substrate bulk density and the volume proportion of substrate ingredients). Results showed that the total transplanting success rate for the end-effector was 100%, and the root plug harm rate was below 17%. A force measure system with tension and pressure transducers was installed on the designed end-effector. The adhesive force FL between the root plug and the cell of seedling trays and the extrusion force FK on the root plug were measured and analyzed. The results showed that all three variable factors and their interactions had significant effects on the extrusion force. Each factor had a significant effect on adhesive force. Additionally, it was found that the end-effector did not perform very well when the value of FK/FL was beyond the range of 5.99~8.67. This could provide a scientific basis for end-effector application in transplanting.
Design and force analysis of end-effector for plug seedling transplanter
Hu, Yang; Jiang, Huanyu; Tong, Junhua
2017-01-01
Automatic transplanters have been very important in greenhouses since the popularization of seedling nurseries. End-effector development is a key technology for transplanting plug seedlings. Most existing end-effectors have problems with holding root plugs or releasing plugs. An efficient end-effector driven by a linear pneumatic cylinder was designed in this study, which could hold root plugs firmly and release plugs easily. This end-effector with four needles could clamp the plug simultaneously while the needles penetrate into the substrate. The depth and verticality of the needles could be adjusted conveniently for different seedling trays. The effectiveness of this end-effector was tested by a combinational trial examining three seedling nursery factors (the moisture content of the substrate, substrate bulk density and the volume proportion of substrate ingredients). Results showed that the total transplanting success rate for the end-effector was 100%, and the root plug harm rate was below 17%. A force measure system with tension and pressure transducers was installed on the designed end-effector. The adhesive force FL between the root plug and the cell of seedling trays and the extrusion force FK on the root plug were measured and analyzed. The results showed that all three variable factors and their interactions had significant effects on the extrusion force. Each factor had a significant effect on adhesive force. Additionally, it was found that the end-effector did not perform very well when the value of FK/FL was beyond the range of 5.99~8.67. This could provide a scientific basis for end-effector application in transplanting. PMID:28678858
Waddell, B.; May, T.
1995-01-01
A single muscle plug was collected from each of 25 live razorback suckers inhabiting the Colorado River basin and analyzed for selenium by instrumental neutron activation. Eight fish from Ashley Creek and three from Razorback Bar exhibited selenium concentrations exceeding 8 μg/g, a level associated with reproductive failure in fish. Concentrations of selenium in eggs and milt were significantly correlated with selenium concentrations in muscle plugs and together indicate a possible explanation for the decline of this species in the Colorado River basin. Muscle plugs (<50mg) and muscle tissue (20 g) were collected from dorsal, anterior, and posterior areas of common carp, flannelmouth sucker, and an archived razorback sucker and analyzed for selenium. Concentrations of selenium in muscle plugs were significantly correlated with selenium concentrations in muscle tissue from the same location and fish (r=0.97). Coefficients of variation for selenium concentrations in each fish were <6.5% for muscle tissue, but ranged from 1.5 to 32.4% for muscle plugs. Increased variation in muscle plugs was attributed to lower selenium concentrations found in the anterior muscle plugs of flannelmouth suckers. Mean selenium concentrations in muscle plugs and tissue from dorsal and posterior areas and muscle tissue from the anterior area were not significantly different. The non-lethal collection of a muscle plug from dorsal and posterior areas of the razorback sucker and other fish species may provide an accurate assessment of selenium concentrations that exist in adjacent muscle tissue.
Xiao, Yong Jie; Chen, Fu Quan; Dong, Yi Zhi
2016-01-01
During driving sleeve of cast-in-place piles by vibratory hammers, soils were squeezed into sleeve and then soil plugging was formed. The physic-mechanical properties of the soil plug have direct influence on the load transmission between the sleeve wall and soil plug. Nevertheless, the researches on this issue are insufficient. In this study, finite element and infinite element coupling model was introduced, through the commercial code ABAQUS, to simulate the full penetration process of the sleeve driven from the ground surface to the desired depth by applying vibratory hammers. The research results indicated that the cyclic shearing action decreases both in soil shear strength and in granular cementation force when the sleeve is driven by vibratory hammers, which leads to a partially plugged mode of the soil plug inside the sleeve. Accordingly, the penetration resistance of sleeve driven by vibratory hammers is the smallest compared to those by other installation methods. When driving the sleeve, the annular soil arches forming in the soil plug at sleeve end induce a significant rise in the internal shaft resistance. Moreover, the influence of vibration frequencies, sleeve diameters, and soil layer properties on the soil plug was investigated in detail, and at the same time improved formulas were brought forward to describe the soil plug resistance inside vibratory driven sleeve.
PLUG STORAGE BUILDING, TRA611, AWAITS SHIELDING SOIL TO BE PLACED ...
PLUG STORAGE BUILDING, TRA-611, AWAITS SHIELDING SOIL TO BE PLACED OVER PLUG STORAGE TUBES. WING WALLS WILL SUPPORT EARTH FILL. MTR, PROCESS WATER BUILDING, AND WORKING RESERVOIR IN VIEW BEYOND PLUG STORAGE. CAMERA FACES NORTHEAST. INL NEGATIVE NO. 2949. Unknown Photographer, 7/30/1951 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
Alternative Fuels Data Center: Los Angeles Sets the Stage for Plug-In
Electric Vehicles Los Angeles Sets the Stage for Plug-In Electric Vehicles to someone by E-mail Share Alternative Fuels Data Center: Los Angeles Sets the Stage for Plug-In Electric Vehicles on Facebook Tweet about Alternative Fuels Data Center: Los Angeles Sets the Stage for Plug-In Electric
30 CFR 250.1715 - How must I permanently plug a well?
Code of Federal Regulations, 2012 CFR
2012-07-01
...) Zones in open hole, Cement plug(s) set from at least 100 feet below the bottom to 100 feet above the top... cement plug, set by the displacement method, at least 100 feet above and below deepest casing shoe; (ii) A cement retainer with effective back-pressure control set 50 to 100 feet above the casing shoe, and...
30 CFR 250.1715 - How must I permanently plug a well?
Code of Federal Regulations, 2014 CFR
2014-07-01
...) Zones in open hole, Cement plug(s) set from at least 100 feet below the bottom to 100 feet above the top... cement plug, set by the displacement method, at least 100 feet above and below deepest casing shoe; (ii) A cement retainer with effective back-pressure control set 50 to 100 feet above the casing shoe, and...
30 CFR 250.1715 - How must I permanently plug a well?
Code of Federal Regulations, 2013 CFR
2013-07-01
...) Zones in open hole, Cement plug(s) set from at least 100 feet below the bottom to 100 feet above the top... cement plug, set by the displacement method, at least 100 feet above and below deepest casing shoe; (ii) A cement retainer with effective back-pressure control set 50 to 100 feet above the casing shoe, and...
30 CFR 250.1715 - How must I permanently plug a well?
Code of Federal Regulations, 2011 CFR
2011-07-01
... in open hole Cement plug(s) set from at least 100 feet below the bottom to 100 feet above the top of... cement plug, set by the displacement method, at least 100 feet above and below deepest casing shoe;(ii) A cement retainer with effective back-pressure control set 50 to 100 feet above the casing shoe, and a...
Electric and Plug-In Hybrid Electric Fleet Vehicle Testing | Transportation
Research | NREL Electric and Plug-In Hybrid Electric Fleet Vehicle Evaluations Electric and Plug-In Hybrid Electric Fleet Vehicle Evaluations How Electric and Plug-In Hybrid Electric Vehicles Work EVs use batteries to store the electric energy that powers the motor. EV batteries are charged by
NASA Technical Reports Server (NTRS)
Yamamoto, K.; Brausch, J. F.; Balsa, T. F.; Janardan, B. A.; Knott, P. R.
1984-01-01
Seven single stream model nozzles were tested in the Anechoic Free-Jet Acoustic Test Facility to evaluate the effectiveness of convergent divergent (C-D) flowpaths in the reduction of shock-cell noise under both static and mulated flight conditions. The test nozzles included a baseline convergent circular nozzle, a C-D circular nozzle, a convergent annular plug nozzle, a C-D annular plug nozzle, a convergent multi-element suppressor plug nozzle, and a C-D multi-element suppressor plug nozzle. Diagnostic flow visualization with a shadowgraph and aerodynamic plume measurements with a laser velocimeter were performed with the test nozzles. A theory of shock-cell noise for annular plug nozzles with shock-cells in the vicinity of the plug was developed. The benefit of these C-D nozzles was observed over a broad range of pressure ratiosin the vicinity of their design conditions. At the C-D design condition, the C-D annual nozzle was found to be free of shock-cells on the plug.
Integrated geophysical surveys for mapping lati-andesite intrusive bodies, Chino Valley, Arizona
El-Kaliouby, Hesham; Sternberg, Ben K.; Hoffmann, John P.; Langenheim, V.E.
2012-01-01
Three different geophysical methods (magnetic, transient electromagnetic (TEM) and gravity) were used near Chino Valley, Arizona, USA in order to map a suspected lati-andesite intrusive body (plug) previously located by interpretation of aeromagnetic data. The magnetic and TEM surveys provided the best indication of the location and depth of the plug. The north-south spatial extent of this plug was estimated to be approximately 600 meters. The depth to the top of the plug was found from the TEM survey to be approximately 350 meters near the center of the survey. The location of the plug defined by the ground magnetic data is consistent with that from the TEM data. Gravity data mostly image the basin-basement interface with a small contribution from the plug of about 0.5 mGal. Results from this investigation can be used to help define the irregular subsurface topography caused by several intrusive lati-andesite plugs that could influence groundwater flow in the area.
NASA Technical Reports Server (NTRS)
Indoe, William
2012-01-01
A gas-charging plug can be easily analyzed for random vibration. The design features two steeped O-rings in a radial configuration at two different diameters, with a 0.050-in. (.1.3-mm) diameter through-hole between the two O-rings. In the charging state, the top O-ring is engaged and sealing. The bottom O-ring outer diameter is not squeezed, and allows air to flow by it into the tank. The inner diameter is stretched to plug the gland diameter, and is restrained by the O-ring groove. The charging port bushing provides mechanical stop to restrain the plug during gas charge removal. It also prevents the plug from becoming a projectile when removing gas charge from the accumulator. The plug can easily be verified after installation to ensure leakage requirements are met.
High temperature penetrator assembly with bayonet plug and ramp-activated lock
NASA Technical Reports Server (NTRS)
Wood, K. E. (Inventor)
1982-01-01
A penetration apparatus, for very high temperature applications in which a base plug is inserted into an opening through a bulkhead is described. The base plug has a head shape and is seated against the highest temperature surface of the bulkhead, which may be the skin of the nose cone or other part of a space vehicle intended for nondestructive atmospheric reentry. From the second side of the bulkhead at which the less severe environment is extant, a bayonet plug is inserted into the base plug and engages an internal shoulder at about 90 deg rotation. The bayonet plug has an integral flanged portion and a pair of ramping washers which are located between the flange and the second bulkhead surface with a spacing washer as necessary.
Miniature electrical connector
Casper, Robert F.
1976-01-01
A miniature coaxial cable electrical connector includes an annular compressible gasket in a receptacle member, the gasket having a generally triangular cross section resiliently engaging and encircling a conically tapered outer surface of a plug member to create an elongated current leakage path at their interface; means for preventing rotation of the plug relative to the receptacle; a metal sleeve forming a portion of the receptacle and encircling the plug member when interconnected; and a split ring in the plug having outwardly and rearwardly projecting fingers spaced from and encircling a portion of a coaxial cable and engageable with the metal sleeve to interlock the receptacle and plug.
Partial wetting gas-liquid segmented flow microreactor.
Kazemi Oskooei, S Ali; Sinton, David
2010-07-07
A microfluidic reactor strategy for reducing plug-to-plug transport in gas-liquid segmented flow microfluidic reactors is presented. The segmented flow is generated in a wetting portion of the chip that transitions downstream to a partially wetting reaction channel that serves to disconnect the liquid plugs. The resulting residence time distributions show little dependence on channel length, and over 60% narrowing in residence time distribution as compared to an otherwise similar reactor. This partial wetting strategy mitigates a central limitation (plug-to-plug dispersion) while preserving the many attractive features of gas-liquid segmented flow reactors.
Punctal occlusion for dry eye syndrome.
Ervin, Ann-Margret; Law, Andrew; Pucker, Andrew D
2017-06-26
Dry eye syndrome is a disorder of the tear film that is associated with symptoms of ocular discomfort. Punctal occlusion is a mechanical treatment that blocks the tear drainage system in order to aid in the preservation of natural tears on the ocular surface. To assess the effects of punctal plugs versus no punctal plugs, different types of punctal plugs, and other interventions for managing dry eye. We searched the Cochrane Central Register of Controlled Trials (CENTRAL) (which contains the Cochrane Eyes and Vision Trials Register) (2016, Issue 11), MEDLINE Ovid (1946 to 8 December 2016), Embase.com (1947 to 8 December 2016), PubMed (1948 to 8 December 2016), LILACS (Latin American and Caribbean Health Sciences Literature Database) (1982 to 8 December 2016), the metaRegister of Controlled Trials (mRCT) (www.controlled-trials.com; last searched 18 November 2012 - this resource is now archived), ClinicalTrials.gov (www.clinicaltrials.gov; searched 8 December 2016), and the WHO International Clinical Trials Registry Platform (ICTRP) (www.who.int/ictrp/search/en; searched 8 December 2016). We did not use any date or language restrictions in the electronic searches for trials. We also searched the Science Citation Index-Expanded database and reference lists of included studies. The evidence was last updated on 8 December 2016 SELECTION CRITERIA: We included randomized and quasi-randomized controlled trials of collagen or silicone punctal plugs in symptomatic participants diagnosed with aqueous tear deficiency or dry eye syndrome. Two review authors independently assessed trial quality and extracted data. We contacted study investigators for additional information when needed. We included 18 trials (711 participants, 1249 eyes) from Austria, Canada, China, Greece, Japan, Mexico, Netherlands, Turkey, the UK, and the USA in this review. We also identified one ongoing trial. Overall we judged these trials to be at unclear risk of bias because they were poorly reported. We assessed the evidence for eight comparisons.Five trials compared punctal plugs with no punctal plugs (control). Three of these trials employed a sham treatment and two trials observed the control group. Two trials did not report outcome data relevant to this review. There was very low-certainty evidence on symptomatic improvement. The three trials that reported this outcome used different scales to measure symptoms. In all three trials, there was little or no improvement in symptom scores with punctal plugs compared with no punctal plugs. Low-certainty evidence from one trial suggested less ocular surface staining in the punctal plug group compared with the no punctal plug group however this difference was small and possibly clinically unimportant (mean difference (MD) in fluorescein staining score -1.50 points, 95% CI -1.88 to -1.12; eyes = 61). Similarly there was a small difference in tear film stability with people in the punctal plug group having more stability (MD 1.93 seconds more, 95% CI 0.67 to 3.20; eyes = 28, low-certainty evidence). The number of artificial tear applications was lower in the punctal plug group compared with the no punctal plugs group in one trial (MD -2.70 applications, 95% CI -3.11 to -2.29; eyes = 61, low-certainty evidence). One trial with low-certainty evidence reported little or no difference between the groups in Schirmer scores, but did not report any quantitative data on aqueous tear production. Very low-certainty evidence on adverse events suggested that events occurred reasonably frequently in the punctal plug group and included epiphora, itching, tenderness and swelling of lids with mucous discharge, and plug displacement.One trial compared punctal plugs with cyclosporine (20 eyes) and one trial compared punctal plugs with oral pilocarpine (55 eyes). The evidence was judged to be very low-certainty due to a combination of risk of bias and imprecision.Five trials compared punctal plugs with artificial tears. In one of the trials punctal plugs was combined with artificial tears and compared with artificial tears alone. There was very low-certainty evidence on symptomatic improvement. Low-certainty evidence of little or no improvement in ocular surface staining comparing punctal plugs with artificial tears (MD right eye 0.10 points higher, 0.56 lower to 0.76 higher, MD left eye 0.60 points higher, 0.10 to 1.10 higher) and low-certainty evidence of little or no difference in aqueous tear production (MD 0.00 mm/5 min, 0.33 lower to 0.33 higher)Three trials compared punctal plugs in the upper versus the lower puncta, and none of them reported the review outcomes at long-term follow-up. One trial with very low-certainty evidence reported no observed complications, but it was unclear which complications were collected.One trial compared acrylic punctal plugs with silicone punctal plugs and the trial reported outcomes at approximately 11 weeks of follow-up (36 eyes). The evidence was judged to be very low-certainty due to a combination of risk of bias and imprecision.One trial compared intracanalicular punctal plugs with silicone punctal plugs at three months follow-up (57 eyes). The evidence was judged to be very low-certainty due to a combination of risk of bias and imprecision.Finally, two trials with very low-certainty evidence compared collagen punctal plugs versus silicone punctal plugs (98 eyes). The evidence was judged to be very low-certainty due to a combination of risk of bias and imprecision. Although the investigators of the individual trials concluded that punctal plugs are an effective means for treating dry eye signs and symptoms, the evidence in this systematic review suggests that improvements in symptoms and commonly tested dry eye signs are inconclusive. Despite the inclusion of 11 additional trials, the findings of this updated review are consistent with the previous review published in 2010. The type of punctal plug investigated, the type and severity of dry eye being treated, and heterogeneity in trial methodology confounds our ability to make decisive statements regarding the effectiveness of punctal plug use. Although punctal plugs are believed to be relatively safe, their use is commonly associated with epiphora and, less commonly, with inflammatory conditions such as dacryocystitis.
Punctal occlusion for dry eye syndrome
Ervin, Ann-Margret; Law, Andrew; Pucker, Andrew D
2017-01-01
Background Dry eye syndrome is a disorder of the tear film that is associated with symptoms of ocular discomfort. Punctal occlusion is a mechanical treatment that blocks the tear drainage system in order to aid in the preservation of natural tears on the ocular surface. Objectives To assess the effects of punctal plugs versus no punctal plugs, different types of punctal plugs, and other interventions for managing dry eye. Search methods We searched the Cochrane Central Register of Controlled Trials (CENTRAL) (which contains the Cochrane Eyes and Vision Trials Register) (2016, Issue 11), MEDLINE Ovid (1946 to 8 December 2016), Embase.com (1947 to 8 December 2016), PubMed (1948 to 8 December 2016), LILACS (Latin American and Caribbean Health Sciences Literature Database) (1982 to 8 December 2016), the metaRegister of Controlled Trials (mRCT) (www.controlled-trials.com; last searched 18 November 2012 - this resource is now archived), ClinicalTrials.gov (www.clinicaltrials.gov; searched 8 December 2016), and the WHO International Clinical Trials Registry Platform (ICTRP) (www.who.int/ictrp/search/en; searched 8 December 2016). We did not use any date or language restrictions in the electronic searches for trials. We also searched the Science Citation Index-Expanded database and reference lists of included studies. The evidence was last updated on 8 December 2016 Selection criteria We included randomized and quasi-randomized controlled trials of collagen or silicone punctal plugs in symptomatic participants diagnosed with aqueous tear deficiency or dry eye syndrome. Data collection and analysis Two review authors independently assessed trial quality and extracted data. We contacted study investigators for additional information when needed. Main results We included 18 trials (711 participants, 1249 eyes) from Austria, Canada, China, Greece, Japan, Mexico, Netherlands, Turkey, the UK, and the USA in this review. We also identified one ongoing trial. Overall we judged these trials to be at unclear risk of bias because they were poorly reported. We assessed the evidence for eight comparisons. Five trials compared punctal plugs with no punctal plugs (control). Three of these trials employed a sham treatment and two trials observed the control group. Two trials did not report outcome data relevant to this review. There was very low-certainty evidence on symptomatic improvement. The three trials that reported this outcome used different scales to measure symptoms. In all three trials, there was little or no improvement in symptom scores with punctal plugs compared with no punctal plugs. Low-certainty evidence from one trial suggested less ocular surface staining in the punctal plug group compared with the no punctal plug group however this difference was small and possibly clinically unimportant (mean difference (MD) in fluorescein staining score -1.50 points, 95% CI -1.88 to -1.12; eyes = 61). Similarly there was a small difference in tear film stability with people in the punctal plug group having more stability (MD 1.93 seconds more, 95% CI 0.67 to 3.20; eyes = 28, low-certainty evidence). The number of artificial tear applications was lower in the punctal plug group compared with the no punctal plugs group in one trial (MD -2.70 applications, 95% CI -3.11 to -2.29; eyes = 61, low-certainty evidence). One trial with low-certainty evidence reported little or no difference between the groups in Schirmer scores, but did not report any quantitative data on aqueous tear production. Very low-certainty evidence on adverse events suggested that events occurred reasonably frequently in the punctal plug group and included epiphora, itching, tenderness and swelling of lids with mucous discharge, and plug displacement. One trial compared punctal plugs with cyclosporine (20 eyes) and one trial compared punctal plugs with oral pilocarpine (55 eyes). The evidence was judged to be very low-certainty due to a combination of risk of bias and imprecision. Five trials compared punctal plugs with artificial tears. In one of the trials punctal plugs was combined with artificial tears and compared with artificial tears alone. There was very low-certainty evidence on symptomatic improvement. Low-certainty evidence of little or no improvement in ocular surface staining comparing punctal plugs with artificial tears (MD right eye 0.10 points higher, 0.56 lower to 0.76 higher, MD left eye 0.60 points higher, 0.10 to 1.10 higher) and low-certainty evidence of little or no difference in aqueous tear production (MD 0.00 mm/5 min, 0.33 lower to 0.33 higher) Three trials compared punctal plugs in the upper versus the lower puncta, and none of them reported the review outcomes at long-term follow-up. One trial with very low-certainty evidence reported no observed complications, but it was unclear which complications were collected. One trial compared acrylic punctal plugs with silicone punctal plugs and the trial reported outcomes at approximately 11 weeks of follow-up (36 eyes). The evidence was judged to be very low-certainty due to a combination of risk of bias and imprecision. One trial compared intracanalicular punctal plugs with silicone punctal plugs at three months follow-up (57 eyes). The evidence was judged to be very low-certainty due to a combination of risk of bias and imprecision. Finally, two trials with very low-certainty evidence compared collagen punctal plugs versus silicone punctal plugs (98 eyes). The evidence was judged to be very low-certainty due to a combination of risk of bias and imprecision. Authors' conclusions Although the investigators of the individual trials concluded that punctal plugs are an effective means for treating dry eye signs and symptoms, the evidence in this systematic review suggests that improvements in symptoms and commonly tested dry eye signs are inconclusive. Despite the inclusion of 11 additional trials, the findings of this updated review are consistent with the previous review published in 2010. The type of punctal plug investigated, the type and severity of dry eye being treated, and heterogeneity in trial methodology confounds our ability to make decisive statements regarding the effectiveness of punctal plug use. Although punctal plugs are believed to be relatively safe, their use is commonly associated with epiphora and, less commonly, with inflammatory conditions such as dacryocystitis. PMID:28649802
40 CFR 147.3108 - Plugging Class I, II, and III wells.
Code of Federal Regulations, 2014 CFR
2014-07-01
... with a cement plug from there to at least one hundred (100) feet above the top of the disposal or injection zone. (2) A cement plug shall also be set from a point at least fifty (50) feet below the shoe of... cement plug shall extend from a point at least thirty feet below the ground surface to a point five (5...
40 CFR 147.3108 - Plugging Class I, II, and III wells.
Code of Federal Regulations, 2013 CFR
2013-07-01
... with a cement plug from there to at least one hundred (100) feet above the top of the disposal or injection zone. (2) A cement plug shall also be set from a point at least fifty (50) feet below the shoe of... cement plug shall extend from a point at least thirty feet below the ground surface to a point five (5...
40 CFR 147.3108 - Plugging Class I, II, and III wells.
Code of Federal Regulations, 2012 CFR
2012-07-01
... with a cement plug from there to at least one hundred (100) feet above the top of the disposal or injection zone. (2) A cement plug shall also be set from a point at least fifty (50) feet below the shoe of... cement plug shall extend from a point at least thirty feet below the ground surface to a point five (5...
40 CFR 147.3108 - Plugging Class I, II, and III wells.
Code of Federal Regulations, 2011 CFR
2011-07-01
... with a cement plug from there to at least one hundred (100) feet above the top of the disposal or injection zone. (2) A cement plug shall also be set from a point at least fifty (50) feet below the shoe of... cement plug shall extend from a point at least thirty feet below the ground surface to a point five (5...
Plug Load Behavioral Change Demonstration Project
DOE Office of Scientific and Technical Information (OSTI.GOV)
Metzger, I.; Kandt, A.; VanGeet, O.
2011-08-01
This report documents the methods and results of a plug load study of the Environmental Protection Agency's Region 8 Headquarters in Denver, Colorado, conducted by the National Renewable Energy Laboratory. The study quantified the effect of mechanical and behavioral change approaches on plug load energy reduction and identified effective ways to reduce plug load energy. Load reduction approaches included automated energy management systems and behavioral change strategies.
40 CFR 147.3108 - Plugging Class I, II, and III wells.
Code of Federal Regulations, 2010 CFR
2010-07-01
... with a cement plug from there to at least one hundred (100) feet above the top of the disposal or injection zone. (2) A cement plug shall also be set from a point at least fifty (50) feet below the shoe of... cement plug shall extend from a point at least thirty feet below the ground surface to a point five (5...
Sadeghi, Soroush G; Goldberg, Jay M; Minor, Lloyd B; Cullen, Kathleen E
2009-11-01
Mechanical occlusion (plugging) of the slender ducts of semicircular canals has been used in the clinic as well as in basic vestibular research. Here, we investigated the effect of canal plugging in two macaque monkeys on the horizontal vestibuloocular reflex (VOR) and the responses of vestibular-nerve afferents during passive head rotations. Afferent responses to active head movements were also studied. The horizontal VOR gain decreased after plugging to <0.1 for frequencies <2 Hz but rose to about 0.6 as frequency was increased to 15 Hz. Afferents innervating plugged horizontal canals had response sensitivities that increased with the frequency of passive rotations from <0.01 (spikes/s)/( degrees/s) at 0.5 Hz to values of about 0.2 and 0.5 (spikes/s)/( degrees/s) at 8 Hz for regular and irregular afferents, respectively (<50% of responses in controls). An increase in phase lead was also noted following plugging in afferent discharge, but not in the VOR. Because the phase discrepancy between the VOR and afferent discharge is much larger than that seen in control animals, this suggests that central adaptation shapes VOR dynamics following plugging. The effect of canal plugging on afferent responses can be modeled as an increase in stiffness and a reduction in the dominant time constant and gain in the transfer function describing canal dynamics. Responses were also evident during active head rotations, consistent with the frequency content of these movements. We conclude that canal plugging in macaques is effective only at frequencies <2 Hz. At higher frequencies, afferents show significant responses, with a nearly 90 degrees phase lead, such that they encode near-rotational acceleration. Our results demonstrate that afferents innervating plugged canals respond robustly during voluntary movements, a finding that has implications for understanding the effects of canal plugging in clinical practice.
Sadeghi, Soroush G.; Goldberg, Jay M.; Minor, Lloyd B.
2009-01-01
Mechanical occlusion (plugging) of the slender ducts of semicircular canals has been used in the clinic as well as in basic vestibular research. Here, we investigated the effect of canal plugging in two macaque monkeys on the horizontal vestibuloocular reflex (VOR) and the responses of vestibular-nerve afferents during passive head rotations. Afferent responses to active head movements were also studied. The horizontal VOR gain decreased after plugging to <0.1 for frequencies <2 Hz but rose to about 0.6 as frequency was increased to 15 Hz. Afferents innervating plugged horizontal canals had response sensitivities that increased with the frequency of passive rotations from <0.01 (spikes/s)/(°/s) at 0.5 Hz to values of about 0.2 and 0.5 (spikes/s)/(°/s) at 8 Hz for regular and irregular afferents, respectively (<50% of responses in controls). An increase in phase lead was also noted following plugging in afferent discharge, but not in the VOR. Because the phase discrepancy between the VOR and afferent discharge is much larger than that seen in control animals, this suggests that central adaptation shapes VOR dynamics following plugging. The effect of canal plugging on afferent responses can be modeled as an increase in stiffness and a reduction in the dominant time constant and gain in the transfer function describing canal dynamics. Responses were also evident during active head rotations, consistent with the frequency content of these movements. We conclude that canal plugging in macaques is effective only at frequencies <2 Hz. At higher frequencies, afferents show significant responses, with a nearly 90° phase lead, such that they encode near-rotational acceleration. Our results demonstrate that afferents innervating plugged canals respond robustly during voluntary movements, a finding that has implications for understanding the effects of canal plugging in clinical practice. PMID:19726724
A Polymer Plugging Gel for the Fractured Strata and Its Application
Fan, Xiangyu; Zhao, Pengfei; Zhang, Qiangui; Zhang, Ting; Zhu, Kui; Zhou, Chenghua
2018-01-01
Well leakage of fractured strata is a tricky problem while drilling. This unwieldy problem is usually caused by the poor formation of the cementing degree, the staggered-mesh of the fracture, and the low bearing capacity of the formation, which can also lead to a narrow and even unsafe window of drilling fluid density. For fractured strata, the normal plugging material has the disadvantages of unsuitable size and low strength, resulting in unsuccessful first time plugging and an increase in cost. Therefore, we developed a polymer plugging gel for the fractured strata, named XNGJ-3. XNGJ-3 is mainly made of an acrylamide monomer and is accompanied by the reactive monomers of carboxyl and hydroxyl as ingredients. XNGJ-3 has a low viscosity before gelling. At 80 °C it becomes gelled, and the gelling time was controlled within the required time of the practical application. These conditions are beneficial for making the plugging material enter the crossing fracture smoothly and occlude the fracture. XNGJ-3 also has a good deformability and can avoid being damaged during the process of fracture closure. The well leakage simulated experiment revealed that the bearing capacity of this material can reach 21 MPa and the inverse bearing capacity can reach 20 MPa. These strengths are more than twice that of common polymer plugging gels. Finally, three leaked wells in the fractured strata of the Sichuan Basin were used to verify the plugging effect of XNGJ-3. Compared with other common plugging materials, XNGJ-3 has the advantages of having a higher success rate of first time plugging, a lower economic cost, a shorter work time, and so forth, which indicate that this plugging material has a good engineering application value in dealing with well leakage of fractured strata. PMID:29883407
Xiong, Hui; Sultan, Laith R; Cary, Theodore W; Schultz, Susan M; Bouzghar, Ghizlane; Sehgal, Chandra M
2017-05-01
To assess the diagnostic performance of a leak-plugging segmentation method that we have developed for delineating breast masses on ultrasound images. Fifty-two biopsy-proven breast lesion images were analyzed by three observers using the leak-plugging and manual segmentation methods. From each segmentation method, grayscale and morphological features were extracted and classified as malignant or benign by logistic regression analysis. The performance of leak-plugging and manual segmentations was compared by: size of the lesion, overlap area ( O a ) between the margins, and area under the ROC curves ( A z ). The lesion size from leak-plugging segmentation correlated closely with that from manual tracing ( R 2 of 0.91). O a was higher for leak plugging, 0.92 ± 0.01 and 0.86 ± 0.06 for benign and malignant masses, respectively, compared to 0.80 ± 0.04 and 0.73 ± 0.02 for manual tracings. Overall O a between leak-plugging and manual segmentations was 0.79 ± 0.14 for benign and 0.73 ± 0.14 for malignant lesions. A z for leak plugging was consistently higher (0.910 ± 0.003) compared to 0.888 ± 0.012 for manual tracings. The coefficient of variation of A z between three observers was 0.29% for leak plugging compared to 1.3% for manual tracings. The diagnostic performance, size measurements, and observer variability for automated leak-plugging segmentations were either comparable to or better than those of manual tracings.
Dust-tolerant electrical connector
NASA Technical Reports Server (NTRS)
Sadick, Shazad (Inventor); Herman, Jason (Inventor); Roberts, Dustyn (Inventor)
2011-01-01
A connector assembly includes releasably mateable plug and receptacle units. At least one socket is enclosed within the receptacle unit and is aligned with at least one permeable membrane disposed in the front end of the receptacle unit. The plug unit includes a body slidably mounted within a longitudinal bore therein. At least one pin extends from the front end of the body and is aligned with at least one permeable membrane disposed in the front end of the plug unit. The plug unit is biased toward a first, de-mate position in which the body is extended rearwardly such that the pin is enclosed with the plug unit and is slidable to a second, mate position in which the body is compressed forwardly such that the pin projects through the permeable membranes of the plug and receptacle units to electrically connect with the socket.
Self locking drive system for rotating plug of a nuclear reactor
Brubaker, James E.
1979-01-01
This disclosure describes a self locking drive system for rotating the plugs on the head of a nuclear reactor which is able to restrain plug motion if a seismic event should occur during reactor refueling. A servomotor is engaged via a gear train and a bull gear to the plug. Connected to the gear train is a feedback control system which allows the motor to rotate the plug to predetermined locations for refueling of the reactor. The gear train contains a self locking double enveloping worm gear set. The worm gear set is utilized for its self locking nature to prevent unwanted rotation of the plugs as the result of an earthquake. The double enveloping type is used because its unique contour spreads the load across several teeth providing added strength and allowing the use of a conventional size worm.
NASA Astrophysics Data System (ADS)
Done, Bogdan
2017-10-01
Over the past 30 years numerous studies and laboratory experiments have researched the use of laser energy to ignite gas and fuel-air mixtures. The actual implementation of this laser application has still to be fully achieved in a commercial automotive application. Laser Plug Ignition as a replacement for Spark Plug Ignition in the internal combustion engines of automotive vehicles, offers several potential benefits such as extending lean burn capability, reducing the cyclic variability between combustion cycles and decreasing the total amount of ignition costs, and implicitly weight and energy requirements. The paper presents preliminary results of cycle variability study carried on a SI Engine equipped with laser Plug Ignition system. Versus classic ignition system, the use of the laser Plug Ignition system assures the reduction of the combustion process variability, reflected in the lower values of the coefficient of variability evaluated for indicated mean effective pressure, maximum pressure, maximum pressure angle and maximum pressure rise rate. The laser plug ignition system was mounted on an experimental spark ignition engine and tested at the regime of 90% load and 2800 rev/min, at dosage of λ=1.1. Compared to conventional spark plug, laser ignition assures the efficiency at lean dosage.
Friction Pull Plug Welding in Aluminum Alloys
NASA Technical Reports Server (NTRS)
Brooke, Shane A.; Bradford, Vann; Burkholder, Jonathon
2011-01-01
NASA fs Marshall Space Flight Center (MSFC) has recently invested much time and effort into the process development of Friction Pull Plug Welding (FPPW). FPPW, is a welding process similar to Friction Push Plug Welding in that, there is a small rotating part (plug) being spun and simultaneously pulled (forged) into a larger part. These two processes differ, in that push plug welding requires an internal reaction support, while pull plug welding reacts to the load externally. FPPW was originally conceived as a post proof repair technique for External Tank. FPPW was easily selected as the primary process used to close out the termination hole on the Constellation Program fs ARES I Upper Stage circumferential Self ] Reacting Friction Stir Welds (SR ]FSW). The versatility of FPPW allows it to also be used as a repair technique for both SR ]FSW and Conventional Friction Stir Welds. To date, all MSFC led development has been concentrated on aluminum alloys (2195, 2219, and 2014). Much work has been done to fully understand and characterize the process fs limitations. A heavy emphasis has been spent on plug design, to match the various weldland thicknesses and alloy combinations. This presentation will summarize these development efforts including weld parameter development, process control, parameter sensitivity studies, plug repair techniques, material properties including tensile, fracture and failure analysis.
Friction Pull Plug Welding in Aluminum Alloys
NASA Technical Reports Server (NTRS)
Brooke, Shane A.; Bradford, Vann
2012-01-01
NASA's Marshall Space Flight Center (MSFC) has recently invested much time and effort into the process development of Friction Pull Plug Welding (FPPW). FPPW, is a welding process similar to Friction Push Plug Welding in that, there is a small rotating part (plug) being spun and simultaneously pulled (forged) into a larger part. These two processes differ, in that push plug welding requires an internal reaction support, while pull plug welding reacts to the load externally. FPPW was originally conceived as a post proof repair technique for the Space Shuttle fs External Tank. FPPW was easily selected as the primary weld process used to close out the termination hole on the Constellation Program's ARES I Upper Stage circumferential Self-Reacting Friction Stir Welds (SR-FSW). The versatility of FPPW allows it to also be used as a repair technique for both SR-FSW and Conventional Friction Stir Welds. To date, all MSFC led development has been concentrated on aluminum alloys (2195, 2219, and 2014). Much work has been done to fully understand and characterize the process's limitations. A heavy emphasis has been spent on plug design, to match the various weldland thicknesses and alloy combinations. This presentation will summarize these development efforts including weld parameter development, process control, parameter sensitivity studies, plug repair techniques, material properties including tensile, fracture and failure analysis.
33 CFR 183.556 - Plugs and fittings.
Code of Federal Regulations, 2010 CFR
2010-07-01
...) BOATING SAFETY BOATS AND ASSOCIATED EQUIPMENT Fuel Systems Manufacturer Requirements § 183.556 Plugs and fittings. (a) A fuel system must not have a fitting for draining fuel. (b) A plug used to service the fuel...
NASA Technical Reports Server (NTRS)
Wojciechowski, Bogdan V. (Inventor); Pegg, Robert J. (Inventor)
2003-01-01
A fast-acting valve includes an annular valve seat that defines an annular valve orifice between the edges of the annular valve seat, an annular valve plug sized to cover the valve orifice when the valve is closed, and a valve-plug holder for moving the annular valve plug on and off the annular valve seat. The use of an annular orifice reduces the characteristic distance between the edges of the valve seat. Rather than this distance being equal to the diameter of the orifice, as it is for a conventional circular orifice, the characteristic distance equals the distance between the inner and outer radii (for a circular annulus). The reduced characteristic distance greatly reduces the gap required between the annular valve plug and the annular valve seat for the valve to be fully open, thereby greatly reducing the required stroke and corresponding speed and acceleration of the annular valve plug. The use of a valve-plug holder that is under independent control to move the annular valve plug between its open and closed positions is important for achieving controllable fast operation of the valve.
NASA Technical Reports Server (NTRS)
Silsbee, F B; Loeb, L B; Sawyer, L G; Fonseca, E L; Dickinson, H C; Agnew, P G
1920-01-01
The successful operation of the spark plug depends to a large extent on the gas tightness of the plug. Part 1 of this report describes the method used for measuring the gas tightness of aviation spark plugs. Part 2 describes the methods used in testing the electrical conductivity of the insulation material when hot. Part 3 describes the testing of the cold dielectric strength of the insulation material, the resistance to mechanical shock, and the final engine test.
Flow plug with length-to-hole size uniformity for use in flow conditioning and flow metering
NASA Technical Reports Server (NTRS)
England, John Dwight (Inventor); Kelley, Anthony R. (Inventor)
2012-01-01
A flow plug of varying thickness has a plurality of holes formed therethrough. The plug fits in a conduit such that a fluid flow in the conduit passes through the plug's holes. Each hole is defined by a parameter indicative of size in terms of the cross-sectional area thereof. A ratio of hole length-to-parameter is approximately the same for all of the holes.
Small Intestinal Submucosa Plug for Closure of Dilated Nephrostomy Tracts: A Pilot Study in Swine
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kakizawa, Hideyaki; Conlin, M. J.; Pavcnik, Dusan, E-mail: pavcnikd@ohsu.edu
2010-06-15
The aim of this study was to evaluate efficacy of a plug made of small intestinal submucosa (SIS) for closure of dilated nephrostomy tract in the kidney after nephroscopy. Ten kidneys in 5 swine had nephrostomy tracts dilated up to 8 mm. The SIS plug was placed into the dilated renal cortex under nephroscopic control. Follow-up arteriograms, retrograde pyelograms, and macroscopic and histologic studies at 24 h (n = 4), 6 weeks (n = 2), and 3 months (n = 4) were performed to evaluate the efficacy of the plug. The SIS plug effectively closed the dilated nephrostomy tract. Follow-upmore » studies showed minimal changes of the kidneys, except for 1 small infarction, regarding inflammatory and foreign-body reactions and progressive scarring of the SIS. SIS plug is effective for occlusion of dilated nephrostomy tract after nephroscopy. Its efficacy should be compared with other therapeutic options.« less
Pulse-actuated fuel-injection spark plug
Murray, Ian; Tatro, Clement A.
1978-01-01
A replacement spark plug for reciprocating internal combustion engines that functions as a fuel injector and as a spark plug to provide a "stratified-charge" effect. The conventional carburetor is retained to supply the main fuel-air mixture which may be very lean because of the stratified charge. The replacement plug includes a cylindrical piezoelectric ceramic which contracts to act as a pump whenever an ignition pulse is applied to a central rod through the ceramic. The rod is hollow at its upper end for receiving fuel, it is tapered along its lower length to act as a pump, and it is flattened at its lower end to act as a valve for fuel injection from the pump into the cylinder. The rod also acts as the center electrode of the plug, with the spark jumping from the plug base to the lower end of the rod to thereby provide spark ignition that has inherent proper timing with the fuel injection.
Eddy Current Minimizing Flow Plug for Use in Flow Conditioning and Flow Metering
NASA Technical Reports Server (NTRS)
England, John Dwight (Inventor); Kelley, Anthony R. (Inventor)
2015-01-01
An eddy-current-minimizing flow plug has an outer radial wall with open flow channels formed between the plug's inlet and outlet. The plug has a central region coupled to the inner surface of the outer radial wall. Each open flow channel includes (i) a first portion originating at the inlet and converging to a location in the plug where convergence is contributed to by changes in thickness of the outer radial wall and divergence of the central region, and (ii) a second portion originating in the plug and diverging to the outlet where divergence is contributed to by changes in thickness of the outer radial wall and convergence of the central region. For at least a portion of the open flow channels, a central axis passing through the first and second portions is non-parallel with respect to the given direction of the flow.
Kabera, Fidèle; Dufour, Simon; Keefe, Greg; Roy, Jean-Philippe
2018-04-04
Our objectives were to evaluate the prevalence of quarters with an observable internal teat sealant (ITS) plug at first milking following calving and investigate persistency of ITS residues in milk after calving. An observational cohort study was carried out on 557 quarters of 156 cows treated with ITS in 6 farms in Quebec, Canada. The presence of an ITS plug at first milking and ITS residues in milk at each milking were observed by producers. The effects of various factors on the odds of observing an ITS plug and persistency of ITS residues in milk were studied using generalized logistic mixed and generalized negative binomial mixed models, respectively. Milk samples were taken on the day before dry-off and on 2 occasions after calving for bacterial identification to detect intramammary infection (IMI) using bacteriological culture followed by MALDI-TOF identification. The association between the absence of an ITS plug and the presence of new IMI was assessed using a mixed logistic regression model. Internal teat sealant plugs after calving were more often observed in rear quarters and in quarters receiving ITS alone at drying-off versus antimicrobial and ITS. We observed an average (standard deviation) persistency of 4.0 d (2.3 d). When an ITS plug was still present at first milking (83% of quarters), the elimination of ITS residues in milk after calving was significantly longer (4.5 d, on average) compared with 1.2 d when an ITS plug was absent. In cows with an ITS plug at calving, we observed a higher number of days of excretion in older cows. When a plug could not be observed, rear quarters, older cows, and cows with a long dry period duration excreted ITS residues for a significantly longer period. The lack of a significant association between the absence of a plug and the odds of new IMI at calving suggests that despite the loss of the plug, cows were still protected against new IMI. Although we were able to highlight some statistically significant risk factors explaining persistency of ITS residues following calving, observed differences were often relatively small and, perhaps, not clinically relevant. In conclusion, an ITS plug was present until first milking after calving for 83% quarters, quarters without an ITS plug at first milking appeared to have been protected from new IMI, and ITS residues could be observed in milk up to 12 d in milk. Copyright © 2018 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
Experimental investigation of shock-cell noise reduction for dual-stream nozzles in simulated flight
NASA Technical Reports Server (NTRS)
Janardan, B. A.; Yamamoto, K.; Majjigi, R. K.; Brausch, J. F.
1984-01-01
Six scale-model nozzles were tested in an anechoic facility to evauate the effectiveness of convergent-divergent (C-D) terminations in reducing shock-cell noise of unsuppressed and mechanically suppressed coannular plug nozzles. One hundred fifty-three acoustic test points with inverted velocity profiles were conducted under static and simulated flight conditions. Diagnostic flow visualization with a shadowgraph and velocity measurements with a laser velocimeter were performed on selected plumes. Shock-cells were identified on the plug and downstream of the plug of the unsuppressed convergent coannular nozzle with truncated plug. Broadband peak frequencies predicted with the two shock-cell structures were correlated with the observed spectra using the measured shock-cell spacings. Relative to a convergent circular nozzle, the perceived noise level (PNL) data at an observer angle of 60 deg relative to inlet, indicated a reduction of (1) 6.5 dB and 9.2 dB with unsuppressed C-D coannular nozzle with truncated plug and (2) 7.7 dB and 8.3 dB with suppressed C-D coannular nozzle under static and simulated flight conditions, espectively. The unsuppressed C-D coannular nozzle with truncated plug, operating at the C-D design condition, had shock-cells downstream of the plug with no shock-cells on the plug. The downstream shock-cells were eliminated by replacing the truncated plug with a smooth extension to obtain an additional 2.4 dB and 3 dB front quadrant PNL reduction, under static and simulated flight conditions, respectively. Other results are discussed.
Dual Spark Plugs For Stratified-Charge Rotary Engine
NASA Technical Reports Server (NTRS)
Abraham, John; Bracco, Frediano V.
1996-01-01
Fuel efficiency of stratified-charge, rotary, internal-combustion engine increased by improved design featuring dual spark plugs. Second spark plug ignites fuel on upstream side of main fuel injector; enabling faster burning and more nearly complete utilization of fuel.
Dukas, Jr., Stephen J.
1990-01-01
A bellows sealed plug valve includes a valve body having an inlet passage and an outlet passage, a valve chamber between the inlet and outlet passages. A valve plug has substantially the same shape as the valve chamber and is rotatably disposed therein. A shaft is movable linearly in response to a signal from a valve actuator. A bellows is sealingly disposed between the valve chamber and the valve actuator and means are located between the bellows and the valve plug for converting linear movement of the shaft connected to the valve actuator to rotational movement of the plug. Various means are disclosed including helical thread mechanism, clevis mechanism and rack and pinion mechanism, all for converting linear motion to rotational motion.
NASA Technical Reports Server (NTRS)
Takeshita, Riki (Inventor); Hibbard, Terry L. (Inventor)
2001-01-01
Friction plug welding (FPW) usage is advantageous for friction stir welding (FSW) hole close-outs and weld repairs in 2195 Al--Cu--Li fusion or friction stir welds. Current fusion welding methods of Al--Cu--Li have produced welds containing varied defects. These areas are found by non-destructive examination both after welding and after proof testing. Current techniques for repairing typically small (<0.25) defects weaken the weldment, rely heavily on welders' skill, and are costly. Friction plug welding repairs increase strength, ductility and resistance to cracking over initial weld quality, without requiring much time or operator skill. Friction plug welding while pulling the plug is advantageous because all hardware for performing the weld can be placed on one side of the workpiece.
Exhaust Nozzles for Supersonic Flight with Turbojet Engines
NASA Technical Reports Server (NTRS)
Shillito, Thomas B.; Hearth, Donald P.; Cortright, Edgar M.
1956-01-01
Good internal performance over a wide range of flight conditions can be obtained with either a plug nozzle or a variable ejector nozzle that can provide a divergent shroud at high pressure ratios. For both the ejector and the plug nozzle, external flow can sometimes cause serious drag losses and, for some plug-nozzle installations, external flow can cause serious internal performance losses. Plug-nozzle cooling and design of the secondary-air-flow systems for ejectors were also considered .
Plug-in nanoliter pneumatic liquid dispenser with nozzle design flexibility
Choi, In Ho; Kim, Hojin; Lee, Sanghyun; Baek, Seungbum; Kim, Joonwon
2015-01-01
This paper presents a novel plug-in nanoliter liquid dispensing system with a plug-and-play interface for simple and reversible, yet robust integration of the dispenser. A plug-in type dispenser was developed to facilitate assembly and disassembly with an actuating part through efficient modularization. The entire process for assembly and operation of the plug-in dispenser is performed via the plug-and-play interface in less than a minute without loss of dispensing quality. The minimum volume of droplets pneumatically dispensed using the plug-in dispenser was 124 nl with a coefficient of variation of 1.6%. The dispensed volume increased linearly with the nozzle size. Utilizing this linear relationship, two types of multinozzle dispensers consisting of six parallel channels (emerging from an inlet) and six nozzles were developed to demonstrate a novel strategy for volume gradient dispensing at a single operating condition. The droplet volume dispensed from each nozzle also increased linearly with nozzle size, demonstrating that nozzle size is a dominant factor on dispensed volume, even for multinozzle dispensing. Therefore, the proposed plug-in dispenser enables flexible design of nozzles and reversible integration to dispense droplets with different volumes, depending on the application. Furthermore, to demonstrate the practicality of the proposed dispensing system, we developed a pencil-type dispensing system as an alternative to a conventional pipette for rapid and reliable dispensing of minute volume droplets. PMID:26594263
Kaneko, Kenitiro; Ono, Yasuyuki; Tainaka, Takahisa; Sumida, Wataru; Ando, Hisami
2009-07-01
Symptoms of choledochal cysts are caused by protein plugs made of lithostathine, which block the long common channel and increase pancreaticobiliary ductal pressure. Agents that dissolve protein plugs can provide relief from or prevent symptoms. In the present study, drugs reportedly effective for pancreatic and biliary stones were used in dissolution tests. Protein plugs were obtained from choledochal cysts during surgery in two children (5- and 6-year-old girls). Plugs approximately 2 mm in diameter were immersed in citric acid, tartaric acid, dimethadione, bromhexine, dehydrocholic acid, sodium citrate, hydrochloric acid, and sodium hydroxide solutions under observation with a digital microscope. The pH of each solution was measured using a pH meter. Plugs dissolved in citric acid (5.2 mM; pH 2.64), tartaric acid (6.7 mM; pH 2.51), dimethadione (75 mM; pH 3.70), hydrochloric acid (0.5 mM; pH 3.13), and sodium hydroxide (75 mM; pH 12.75) solutions. Plugs did not dissolve in dimethadione (7.5 mM; pH 4.31), bromhexine (0.1%; pH 4.68), dehydrocholic acid (5%; pH 7.45), and sodium citrate (75 mM; pH 7.23) solutions. Protein plugs in choledochal cysts are dissolved in acidic and basic solutions, which may eliminate longitudinal electrostatic interactions of the lithostathine protofibrils.
NASA SLS Booster Nozzle Plug Pieces Fly During Test
2016-06-28
On June 28, a test version of the booster that will help power NASA's new rocket, the Space Launch System, fired up at nearly 6,000 degrees Fahrenheit for a successful, two-minute qualification test at Orbital ATK's test facilities in Promontory, Utah. This video shows the booster's nozzle plug intentionally breaking apart. The smoky ring coming off the booster is condensed water vapor created by a pressure difference between the motor gas and normal air. The nozzle plug is an environmental barrier to prevent heat, dust and moisture from getting inside the booster before it ignites. The plug isn't always part of a static test but was included on this one due to changes made to the hardware. The foam on the plug is denser than previous NASA launch vehicles, as the engines are now in the same plane as the boosters. A numbered grid was placed on the exterior of the plug before the test so the pieces retrieved could support plug breakup assessment and reconstruction. Along with video, collecting the pieces helps determine the size and speed of them when they break apart. Nozzle plug pieces were found as far as 1,500 to 2,000 feet away from the booster. This is the last full-scale qualification test for the booster before the first, uncrewed flight of SLS with the Orion spacecraft in 2018.
Plug-in nanoliter pneumatic liquid dispenser with nozzle design flexibility.
Choi, In Ho; Kim, Hojin; Lee, Sanghyun; Baek, Seungbum; Kim, Joonwon
2015-11-01
This paper presents a novel plug-in nanoliter liquid dispensing system with a plug-and-play interface for simple and reversible, yet robust integration of the dispenser. A plug-in type dispenser was developed to facilitate assembly and disassembly with an actuating part through efficient modularization. The entire process for assembly and operation of the plug-in dispenser is performed via the plug-and-play interface in less than a minute without loss of dispensing quality. The minimum volume of droplets pneumatically dispensed using the plug-in dispenser was 124 nl with a coefficient of variation of 1.6%. The dispensed volume increased linearly with the nozzle size. Utilizing this linear relationship, two types of multinozzle dispensers consisting of six parallel channels (emerging from an inlet) and six nozzles were developed to demonstrate a novel strategy for volume gradient dispensing at a single operating condition. The droplet volume dispensed from each nozzle also increased linearly with nozzle size, demonstrating that nozzle size is a dominant factor on dispensed volume, even for multinozzle dispensing. Therefore, the proposed plug-in dispenser enables flexible design of nozzles and reversible integration to dispense droplets with different volumes, depending on the application. Furthermore, to demonstrate the practicality of the proposed dispensing system, we developed a pencil-type dispensing system as an alternative to a conventional pipette for rapid and reliable dispensing of minute volume droplets.
Gwon, Dong Il; Ko, Gi-Young; Yoon, Hyun-Ki; Sung, Kyu-Bo; Kim, Jin Hyoung; Shin, Ji Hoon; Ko, Heung Kyu; Song, Ho-Young
2013-07-01
To evaluate technical safety, clinical safety, and effectiveness of vascular plug-assisted retrograde transvenous obliteration (RTO) for treatment of gastric varices (GV) and hepatic encephalopathy (HE). This retrospective study was approved by the institutional review board; written informed consent was waived. From April 2009 to December 2011, 20 patients (13, GV; seven, HE) who had undergone vascular plug-assisted RTO were retrospectively evaluated. After retrograde transvenous placement of a vascular plug in the left adrenal vein or gastrorenal shunt, subsequent gelatin-sponge embolization of both gastrorenal shunt and GV was performed. Follow-up computed tomography (CT) and upper gastrointestinal tract endoscopy were performed; clinical and laboratory data were collected to evaluate primary (technical success, complications, clinical success) and secondary (change of liver function by using the Child-Pugh score, worsening of esophageal varices) end points. Laboratory data before and after vascular plug-assisted RTO were compared (paired-sample t test). Placement of the vascular plug and subsequent gelatin-sponge embolization were technically successful in all 20 patients, with no procedure-related complications. Follow-up CT within 1 week after vascular plug-assisted RTO showed complete thrombosis of GV and gastrorenal shunts in all patients. Clinical symptoms of HE completely resolved in all seven patients with HE; mean serum NH3 level of 127.4 μmol/L ± 58 (standard deviation) before vascular plug-assisted RTO decreased significantly to 28.1 μmol/L ± 9.8 within 1 week after vascular plug-assisted RTO (P = .002). Eighteen patients who underwent follow-up longer than 2 months showed complete obliteration of GV and gastrorenal shunts at CT and endoscopy. There were no cases of variceal bleeding or HE during mean follow-up of 422 days. Improvement in Child-Pugh score was observed in 12 of 18 (67%) patients 1 month after vascular plug-assisted RTO. Worsening of esophageal varices was observed in four (22%) patients at mean follow-up of 9.4 months. Vascular plug-assisted RTO is technically simple and safe and seems to be clinically effective for treatment of GV and HE.
Parallel Eclipse Project Checkout
NASA Technical Reports Server (NTRS)
Crockett, Thomas M.; Joswig, Joseph C.; Shams, Khawaja S.; Powell, Mark W.; Bachmann, Andrew G.
2011-01-01
Parallel Eclipse Project Checkout (PEPC) is a program written to leverage parallelism and to automate the checkout process of plug-ins created in Eclipse RCP (Rich Client Platform). Eclipse plug-ins can be aggregated in a feature project. This innovation digests a feature description (xml file) and automatically checks out all of the plug-ins listed in the feature. This resolves the issue of manually checking out each plug-in required to work on the project. To minimize the amount of time necessary to checkout the plug-ins, this program makes the plug-in checkouts parallel. After parsing the feature, a request to checkout for each plug-in in the feature has been inserted. These requests are handled by a thread pool with a configurable number of threads. By checking out the plug-ins in parallel, the checkout process is streamlined before getting started on the project. For instance, projects that took 30 minutes to checkout now take less than 5 minutes. The effect is especially clear on a Mac, which has a network monitor displaying the bandwidth use. When running the client from a developer s home, the checkout process now saturates the bandwidth in order to get all the plug-ins checked out as fast as possible. For comparison, a checkout process that ranged from 8-200 Kbps from a developer s home is now able to saturate a pipe of 1.3 Mbps, resulting in significantly faster checkouts. Eclipse IDE (integrated development environment) tries to build a project as soon as it is downloaded. As part of another optimization, this innovation programmatically tells Eclipse to stop building while checkouts are happening, which dramatically reduces lock contention and enables plug-ins to continue downloading until all of them finish. Furthermore, the software re-enables automatic building, and forces Eclipse to do a clean build once it finishes checking out all of the plug-ins. This software is fully generic and does not contain any NASA-specific code. It can be applied to any Eclipse-based repository with a similar structure. It also can apply build parameters and preferences automatically at the end of the checkout.
Mating Plugs in Polyandrous Giants: Which Sex Produces Them, When, How and Why?
Kuntner, Matjaž; Kralj-Fišer, Simona; Li, Daiqin
2012-01-01
Background Males usually produce mating plugs to reduce sperm competition. However, females can conceivably also produce mating plugs in order to prevent unwanted, superfluous and energetically costly matings. In spiders–appropriate models for testing plugging biology hypotheses–mating plugs may consist of male genital parts and/or of amorphous covers consisting of glandular or sperm secretions. In the giant wood spider Nephila pilipes, a highly sexually dimorphic and polygamous species, males are known to produce ineffective embolic plugs through genital damage, but nothing is known about the origin and function of additional conspicuous amorphous plugs (AP) covering female genitals. Methodology We tested alternative hypotheses of the nature and function of AP in N. pilipes by staging mating trials with varying degrees of polyandry. No APs were ever formed during mating trials, which rules out the possibility of male AP formation. Instead, those females that oviposited produced the AP from a liquid secreted during egg sac formation. Polyandrous females were more likely to lay eggs and to produce the AP, as were those that mated longer and with more total insertions. Our further tests revealed that, in spite of being a side product of egg sac production, AP, when hardened, prevented any subsequent copulation. Conclusions We conclude that in the giant wood spider (Nephila pilipes), the amorphous mating plugs are not produced by the males, that repeated copulations (most likely polyandrous) are necessary for egg fertilization and AP formation, and that the AP represents a female adaptation to sexual conflict through prevention of unwanted, excessive copulations. Considering the largely unknown origin of amorphous plugs in spiders, we predict that a similar pattern might be detected in other clades, which would help elucidate the evolutionary interplay of various selection pressures responsible for the origin and maintenance of mating plugs. PMID:22829900
Hansen, Lea K; Becher, Naja; Bastholm, Sara; Glavind, Julie; Ramsing, Mette; Kim, Chong J; Romero, Roberto; Jensen, Jørgen S; Uldbjerg, Niels
2014-01-01
To evaluate the microbial load and the inflammatory response in the distal and proximal parts of the cervical mucus plug. Experimental research. Twenty women with a normal, singleton pregnancy. Vaginal swabs and specimens from the distal and proximal parts of the cervical mucus plug. Immunohistochemistry, enzyme-linked immunosorbent assay, quantitative polymerase chain reaction and histology. The total bacterial load (16S rDNA) was significantly lower in the cervical mucus plug compared with the vagina (p = 0.001). Among women harboring Ureaplasma parvum, the median genome equivalents/g were 1574 (interquartile range 2526) in the proximal part, 657 (interquartile range 1620) in the distal part and 60,240 (interquartile range 96,386) in the vagina. Histological examinations and quantitative polymerase chain reaction revealed considerable amounts of lactobacilli and inflammatory cells in both parts of the cervical mucus plug. The matrix metalloproteinase-8 concentration was decreased in the proximal part of the plug compared with the distal part (p = 0.08). The cervical mucus plug inhibits, but does not block, the passage of Ureaplasma parvum during its ascending route from the vagina through the cervical canal. © 2013 Nordic Federation of Societies of Obstetrics and Gynecology.
NASA Technical Reports Server (NTRS)
Svejkovsky, Paul A.
1993-01-01
Protective plug resists slowly built-up pressure or automatically releases itself if pressure rises suddenly. Seals out moisture at pressures ranging from 50 micrometers of mercury to 200 pounds per square inch. Designed to seal throat of 38 Reaction Control Thrusters on Space Shuttle protecting internal components from corrosion. Plug conforms to contour of nozzle throat, where O-ring forms pressure seal. After plug inserted, cover attached by use of cover-fitting assembly. Modified versions useful in protecting engines, pumps, reaction vessels, and other industrial equipment during shipment and maintenance.
Microscopic Evaluation of Friction Plug Welds- Correlation to a Processing Analysis
NASA Technical Reports Server (NTRS)
Rabenberg, Ellen M.; Chen, Poshou; Gorti, Sridhar
2017-01-01
Recently an analysis of dynamic forge load data from the friction plug weld (FPW) process and the corresponding tensile test results showed that good plug welds fit well within an analytically determined processing parameter box. There were, however, some outliers that compromised the predictions. Here the microstructure of the plug weld material is presented in view of the load analysis with the intent of further understanding the FPW process and how it is affected by the grain structure and subsequent mechanical properties.
Local plantar pressure relief in therapeutic footwear: design guidelines from finite element models.
Erdemir, Ahmet; Saucerman, Jeffrey J; Lemmon, David; Loppnow, Bryan; Turso, Brie; Ulbrecht, Jan S; Cavanagh, Peter Re
2005-09-01
A major goal of therapeutic footwear in patients with pain or those at risk for skin injury is to relieve focal loading under prominent metatarsal heads. One frequent approach is to place plugs of compliant material into the midsole of the shoe. This study investigated 36 plug designs, a combination of three materials, six geometries, and two placements using a two-dimensional (2D) finite element model. Realistic loading conditions were obtained from plantar pressures (PP) recorded during walking in five subjects who wore control midsoles manufactured using Microcell Puff. Measured peak pressures underneath the second metatarsal head were similar to the results of the control model. PP obtained from simulations with the plugs built into a firm midsole were compared to the simulation results of the control midsole. Large plugs (e.g. 40 mm width), made out of Microcell Puff Lite or Plastazote Medium, placed at peak pressure sites, resulted in highest reductions in peak pressures (18-28%). Smaller plugs benefited from tapering when placed at high pressure areas. Case studies were completed on a healthy male subject and a diabetic female patient to address the efficacy of a plug design favored by our simulations (pressure based placement, 40 x 20 mm, Plastazote Medium). Successful reductions of second metatarsal head pressures were observed with a mediolateral load redistribution that was not represented by our model. 2D computer simulations allowed systematic investigation of plug properties without the need for high volume experimentation on human subjects and established basic guidelines for plug selection. In particular, plugs that are placed based on plantar pressure measurements were proven to be more effective when compared to those positioned according to the projection of the bony landmark on the foot-shoe plantar contact area.
Coil-On-Plug Ignition for Oxygen/Methane Liquid Rocket Engines in Thermal-Vacuum Environments
NASA Technical Reports Server (NTRS)
Melcher, John C.; Atwell, Matthew J.; Morehead, Robert L.; Hurlbert, Eric A.; Bugarin, Luz; Chaidez, Mariana
2017-01-01
A coil-on-plug ignition system has been developed and tested for Liquid Oxygen (LOX)/liquid methane (LCH4) rocket engines operating in thermal vacuum conditions. The igniters were developed and tested as part of the Integrated Cryogenic Propulsion Test Article (ICPTA), previously tested as part of the Project Morpheus test vehicle. The ICPTA uses an integrated, pressure-fed, cryogenic LOX/LCH4 propulsion system including a reaction control system (RCS) and a main engine. The ICPTA was tested at NASA Glenn Research Center's Plum Brook Station in the Spacecraft Propulsion Research Facility (B-2) under vacuum and thermal vacuum conditions. A coil-on-plug ignition system has been developed to successfully demonstrate ignition reliability at these conditions while preventing corona discharge issues. The ICPTA uses spark plug ignition for both the main engine igniter and the RCS. The coil-on-plug configuration eliminates the conventional high-voltage spark plug cable by combining the coil and the spark plug into a single component. Prior to ICPTA testing at Plum Brook, component-level reaction control engine (RCE) and main engine igniter testing was conducted at NASA Johnson Space Center (JSC), which demonstrated successful hot-fire ignition using the coil-on-plug from sea-level ambient conditions down to 10(exp -2) torr. Integrated vehicle hot-fire testing at JSC demonstrated electrical and command/data system performance. Lastly, hot-fire testing at Plum Brook demonstrated successful ignitions at simulated altitude conditions at 30 torr and cold thermal-vacuum conditions at 6 torr. The test campaign successfully proved that coil-on-plug technology will enable integrated LOX/LCH4 propulsion systems in future spacecraft.
Coil-On-Plug Ignition for LOX/Methane Liquid Rocket Engines in Thermal Vacuum Environments
NASA Technical Reports Server (NTRS)
Melcher, John C.; Atwell, Matthew J.; Morehead, Robert L.; Hurlbert, Eric A.; Bugarin, Luz; Chaidez, Mariana
2017-01-01
A coil-on-plug ignition system has been developed and tested for Liquid Oxygen (LOX) / liquid methane rocket engines operating in thermal vacuum conditions. The igniters were developed and tested as part of the Integrated Cryogenic Propulsion Test Article (ICPTA), previously tested as part of the Project Morpheus test vehicle. The ICPTA uses an integrated, pressure-fed, cryogenic LOX/methane propulsion system including a reaction control system (RCS) and a main engine. The ICPTA was tested at NASA Glenn Research Center's Plum Brook Station in the Spacecraft Propulsion Research Facility (B-2) under vacuum and thermal vacuum conditions. In order to successfully demonstrate ignition reliability in the vacuum conditions and eliminate corona discharge issues, a coil-on-plug ignition system has been developed. The ICPTA uses spark-plug ignition for both the main engine igniter and the RCS. The coil-on-plug configuration eliminates the conventional high-voltage spark plug cable by combining the coil and the spark-plug into a single component. Prior to ICPTA testing at Plum Brook, component-level reaction control engine (RCE) and main engine igniter testing was conducted at NASA Johnson Space Center (JSC), which demonstrated successful hot-fire ignition using the coil-on-plug from sea-level ambient conditions down to 10(exp.-2) torr. Integrated vehicle hot-fire testing at JSC demonstrated electrical and command/data system performance. Lastly, Plum Brook testing demonstrated successful ignitions at simulated altitude conditions at 30 torr and cold thermal-vacuum conditions at 6 torr. The test campaign successfully proved that coil-on-plug technology will enable integrated LOX/methane propulsion systems in future spacecraft.
Abolhasani, Milad; Singh, Mayank; Kumacheva, Eugenia; Günther, Axel
2012-05-07
We present an automated microfluidic (MF) approach for the systematic and rapid investigation of carbon dioxide (CO(2)) mass transfer and solubility in physical solvents. Uniformly sized bubbles of CO(2) with lengths exceeding the width of the microchannel (plugs) were isothermally generated in a co-flowing physical solvent within a gas-impermeable, silicon-based MF platform that is compatible with a wide range of solvents, temperatures and pressures. We dynamically determined the volume reduction of the plugs from images that were accommodated within a single field of view, six different downstream locations of the microchannel at any given flow condition. Evaluating plug sizes in real time allowed our automated strategy to suitably select inlet pressures and solvent flow rates such that otherwise dynamically self-selecting parameters (e.g., the plug size, the solvent segment size, and the plug velocity) could be either kept constant or systematically altered. Specifically, if a constant slug length was imposed, the volumetric dissolution rate of CO(2) could be deduced from the measured rate of plug shrinkage. The solubility of CO(2) in the physical solvent was obtained from a comparison between the terminal and the initial plug sizes. Solubility data were acquired every 5 min and were within 2-5% accuracy as compared to literature data. A parameter space consisting of the plug length, solvent slug length and plug velocity at the microchannel inlet was established for different CO(2)-solvent pairs with high and low gas solubilities. In a case study, we selected the gas-liquid pair CO(2)-dimethyl carbonate (DMC) and volumetric mass transfer coefficients 4-30 s(-1) (translating into mass transfer times between 0.25 s and 0.03 s), and Henry's constants, within the range of 6-12 MPa.
Preparation and Evaluation of Biodegradable Scleral Plug Containing Curcumin in Rabbit Eye.
Zhang, Jun; Sun, Haiyan; Zhou, Nalei; Zhang, Bin; Ma, Jingxue
2017-12-01
To test whether biodegradable curcumin-loaded scleral plug is a promising choice for treating posterior ocular diseases, the study investigated the in vitro release profile of the scleral plug and its safety in vivo. Scleral plugs containing 0.5 mg, 1.0 mg and 1.5 mg curcumin were synthesized by a compression-sintering method. These scleral plugs were placed in tubes containing balanced salt solution (BSS) buffer, which was replaced by fresh buffer daily. The curcumin concentration in the removed aliquot was tested daily for 14 days using high-performance liquid chromatography (HPLC). In the study, 44 rabbits were randomly divided into four groups: control, 0.5 mg, 1.0 mg and 1.5 mg curcumin groups. The scleral plug was trans-scleral fixed in the right eye of the rabbits in the three curcumin-treated groups. The control rabbits only received sclerotomy. The treated rabbit eyes were examined by a slit-lamp biomicroscope, an indirect ophthalmoscope and electroretinogram (ERG), and subjected to histological analysis. The concentration of the 1.5 mg curcumin-loaded scleral plug was higher than 15 μg/ml for consecutive 14 days in vitro. The in vivo experiments revealed intraocular pressure, a-wave and b-wave amplitudes of ERG, and conjunctival reaction degree were not significantly different between the four groups. Retinal structure was normal in the curcumin-treated groups. The sclerotomy wound healed after the plug was completely degraded. Anterior chamber reaction or complications were not observed. The study suggests that curcumin-loaded scleral plug could sustain high concentration of curcumin in vitro and is safe in vivo. It might be a promising alternative choice for the treatment of posterior ocular diseases.
Qiu, Weiqiang; Liu, Ziyuan; Zhang, Zhihong; Ao, Mingxin; Li, Xuemin; Wang, Wei
2012-01-01
This study aimed to compare the effects of treatment with punctal plugs versus artificial tears on visual function and tear film stability for dry eye. A total of 56 consecutive eyes of 28 dry eye patients observed at our clinic from May to October in 2009 were divided into two groups. One group (32 eyes of 16 patients) was treated with artificial tears, and punctal plugs were used in the other group (24 eyes of 12 patients). A questionnaire was used in these patients before treatment and was repeated 2 weeks after treatment. Fluorescent staining for tear film break-up time (BUT), the Schirmer test I (STI), and contrast sensitivity was performed at the same time. The questionnaire indicated that all patients complained about the uncomfortable symptoms associated with dry eye. These symptoms were relieved after the application of artificial tears or punctal plugs, and there was no significant difference between these two groups. We found that the corneal fluorescent staining disappeared after treatment. The BUT was improved significantly after treatment in both groups, but the improvement was greater in patients who received punctal plugs than those that received artificial tears. There was no remarkable change in the STI in the artificial tears group, but a significant change was observed in the punctal plugs group. The contrast sensitivities were greatly improved in simulated daylight, night, and glare disability conditions after treatment with artificial tears and punctal plugs. However, the changes in contrast sensitivity did not significantly differ between groups. Both artificial tears and punctal plugs relieved dry eye symptoms, repaired corneal lesions, enhanced tear film stability, and improved contrast sensitivity. Punctal plugs could improve tear film stability and elongate the BUT better than artificial tears.
Porous plug for reducing orifice induced pressure error in airfoils
NASA Technical Reports Server (NTRS)
Plentovich, Elizabeth B. (Inventor); Gloss, Blair B. (Inventor); Eves, John W. (Inventor); Stack, John P. (Inventor)
1988-01-01
A porous plug is provided for the reduction or elimination of positive error caused by the orifice during static pressure measurements of airfoils. The porous plug is press fitted into the orifice, thereby preventing the error caused either by fluid flow turning into the exposed orifice or by the fluid flow stagnating at the downstream edge of the orifice. In addition, the porous plug is made flush with the outer surface of the airfoil, by filing and polishing, to provide a smooth surface which alleviates the error caused by imperfections in the orifice. The porous plug is preferably made of sintered metal, which allows air to pass through the pores, so that the static pressure measurements can be made by remote transducers.
System and method for charging a plug-in electric vehicle
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bassham, Marjorie A.; Spigno, Jr., Ciro A.; Muller, Brett T.
2017-05-02
A charging system and method that may be used to automatically apply customized charging settings to a plug-in electric vehicle, where application of the settings is based on the vehicle's location. According to an exemplary embodiment, a user may establish and save a separate charging profile with certain customized charging settings for each geographic location where they plan to charge their plug-in electric vehicle. Whenever the plug-in electric vehicle enters a new geographic area, the charging method may automatically apply the charging profile that corresponds to that area. Thus, the user does not have to manually change or manipulate themore » charging settings every time they charge the plug-in electric vehicle in a new location.« less
Molten tin reprocessing of spent nuclear fuel elements
Heckman, Richard A.
1983-01-01
A method and apparatus for reprocessing spent nuclear fuel is described. Within a containment vessel, a solid plug of tin and nitride precipitates supports a circulating bath of liquid tin therein. Spent nuclear fuel is immersed in the liquid tin under an atmosphere of nitrogen, resulting in the formation of nitride precipitates. The layer of liquid tin and nitride precipitates which interfaces the plug is solidified and integrated with the plug. Part of the plug is melted, removing nitride precipitates from the containment vessel, while a portion of the plug remains solidified to support the liquid tin and nitride precipitates remaining in the containment vessel. The process is practiced numerous times until substantially all of the precipitated nitrides are removed from the containment vessel.
National Plug-In Electric Vehicle Infrastructure Analysis
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wood, Eric; Rames, Clement; Muratori, Matteo
This report addresses the fundamental question of how much plug-in electric vehicle (PEV) charging infrastructure—also known as electric vehicle supply equipment (EVSE)—is needed in the United States to support both plug-in hybrid electric vehicles (PHEVs) and battery electric vehicles (BEVs).
Nozzle dam having a unitary plug
Veronesi, L.; Wepfer, R.M.
1992-12-15
Apparatus for sealing the primary-side coolant flow nozzles of a nuclear steam generator is disclosed. The steam generator has relatively small diameter manway openings for providing access to the interior of the steam generator including the inside surface of each nozzle, the manway openings having a diameter substantially less than the inside diameter of each nozzle. The apparatus includes a bracket having an outside surface for matingly sealingly engaging the inside surface of the nozzle. The bracket also has a plurality of openings longitudinally therethrough and a plurality of slots transversely therein in communication with each opening. A plurality of unitary plugs sized to pass through the manway opening are matingly sealingly disposed in each opening of the bracket for sealingly plugging each opening. Each plug includes a plurality of arms operable to engage the slots of the bracket for connecting each plug to the bracket, so that the nozzle is sealed as the plugs seal the openings and are connected to the bracket. 16 figs.
Nozzle dam having a unitary plug
Veronesi, Luciano; Wepfer, Robert M.
1992-01-01
Apparatus for sealing the primary-side coolant flow nozzles of a nuclear steam generator. The steam generator has relatively small diameter manway openings for providing access to the interior of the steam generator including the inside surface of each nozzle, the manway openings having a diameter substantially less than the inside diameter of each nozzle. The apparatus includes a bracket having an outside surface for matingly sealingly engaging the inside surface of the nozzle. The bracket also has a plurality of openings longitudinally therethrough and a plurality of slots transversely therein in communication with each opening. A plurality of unitary plugs sized to pass through the manway opening are matingly sealingly disposed in each opening of the bracket for sealingly plugging each opening. Each plug includes a plurality of arms operable to engage the slots of the bracket for connecting each plug to the bracket, so that the nozzle is sealed as the plugs seal the openings and are connected to the bracket.
Campbell; Heyes; Goldsmith
1999-07-01
Juvenile European starlings, Sturnus vulgaris, were allowed to observe a conspecific demonstrator using its beak to remove one of two distinctively coloured objects (i.e. a red or a black plug) from a hole in the lid of a plastic box. Both plugs could be removed by either pulling up on a loop of string inserted through the centre of the plug, or pushing down on the plug. When subsequently allowed access to the plugs, and rewarded with food for all removal responses, regardless of the object to which they were made and their direction, observer birds removed the same plug in the same direction as their demonstrator. These results suggest that the two-object/two-action paradigm is a valuable procedure for testing for the simultaneous effects of learning about a stimulus and a response, an object and an action, through conspecific observation. Copyright 1999 The Association for the Study of Animal Behaviour.
30 CFR 18.41 - Plug and receptacle-type connectors.
Code of Federal Regulations, 2014 CFR
2014-07-01
... electrically interlocked with an automatic circuit-interrupting device. (i) Mechanically interlocked connectors... shall be removed before the plug can be withdrawn and the electrical energy in the interlocking pilot.... (d) Molded-elastomer connectors will be acceptable provided: (1) Any free space within the plug or...
30 CFR 18.41 - Plug and receptacle-type connectors.
Code of Federal Regulations, 2010 CFR
2010-07-01
... electrically interlocked with an automatic circuit-interrupting device. (i) Mechanically interlocked connectors... shall be removed before the plug can be withdrawn and the electrical energy in the interlocking pilot.... (d) Molded-elastomer connectors will be acceptable provided: (1) Any free space within the plug or...
30 CFR 18.41 - Plug and receptacle-type connectors.
Code of Federal Regulations, 2013 CFR
2013-07-01
... electrically interlocked with an automatic circuit-interrupting device. (i) Mechanically interlocked connectors... shall be removed before the plug can be withdrawn and the electrical energy in the interlocking pilot.... (d) Molded-elastomer connectors will be acceptable provided: (1) Any free space within the plug or...
30 CFR 18.41 - Plug and receptacle-type connectors.
Code of Federal Regulations, 2012 CFR
2012-07-01
... electrically interlocked with an automatic circuit-interrupting device. (i) Mechanically interlocked connectors... shall be removed before the plug can be withdrawn and the electrical energy in the interlocking pilot.... (d) Molded-elastomer connectors will be acceptable provided: (1) Any free space within the plug or...
30 CFR 18.41 - Plug and receptacle-type connectors.
Code of Federal Regulations, 2011 CFR
2011-07-01
... electrically interlocked with an automatic circuit-interrupting device. (i) Mechanically interlocked connectors... shall be removed before the plug can be withdrawn and the electrical energy in the interlocking pilot.... (d) Molded-elastomer connectors will be acceptable provided: (1) Any free space within the plug or...
Intraocular foreign-body hazard during vitrectomy.
Bovino, J A; Marcus, D F
1982-03-01
We noted two instances of forceps-induced fragmentation of the bar used for scleral plug storage during vitreous surgery. The silicone bar material was adherent to the plug in both cases. Because this represents a significant intraocular foreign body hazard, the scleral plug should be carefully inspected before insertion.
Rotating plug bearing and seal
Wade, Elman E.
1977-01-01
A bearing and seal structure for nuclear reactors utilizing rotating plugs above the nuclear reactor vessel. The structure permits lubrication of bearings and seals of the rotating plugs without risk of the lubricant draining into the reactor vessel below. The structure permits lubrication by utilizing a rotating outer race bearing.
Iverson, Richard M.; Sherrod, David R.; Scott, William E.; Stauffer, Peter H.
2008-01-01
The 2004-5 eruption of Mount St. Helens exhibited sustained, near-equilibrium behavior characterized by nearly steady extrusion of a solid dacite plug and nearly periodic occurrence of shallow earthquakes. Diverse data support the hypothesis that these earthquakes resulted from stick-slip motion along the margins of the plug as it was forced incrementally upward by ascending, solidifying, gas-poor magma. I formalize this hypothesis with a mathematical model derived by assuming that magma enters the base of the eruption conduit at a steady rate, invoking conservation of mass and momentum of the magma and plug, and postulating simple constitutive equations that describe magma and conduit compressibilities and friction along the plug margins. Reduction of the model equations reveals a strong mathematical analogy between the dynamics of the magma-plug system and those of a variably damped oscillator. Oscillations in extrusion velocity result from the interaction of plug inertia, a variable upward force due to magma pressure, and a downward force due to the plug weight. Damping of oscillations depends mostly on plug-boundary friction, and oscillations grow unstably if friction exhibits rate weakening similar to that observed in experiments. When growth of oscillations causes the extrusion rate to reach zero, however, gravity causes friction to reverse direction, and this reversal instigates a transition from unstable oscillations to self-regulating stick-slip cycles. The transition occurs irrespective of the details of rate-weakening behavior, and repetitive stick-slip cycles are, therefore, robust features of the system’s dynamics. The presence of a highly compressible elastic driving element (that is, magma containing bubbles) appears crucial for enabling seismogenic slip events to occur repeatedly at the shallow earthquake focal depths (8 N. These results imply that the system’s self-regulating behavior is not susceptible to dramatic change--provided that the rate of magma ascent remains similar to the rate of magma accretion at the base of the plug, that plug surface erosion more or less compensates for mass gain due to basal accretion, and that magma and rock properties do not change significantly. Even if disequilibrium initial conditions are imposed, the dynamics of the magma-plug system are strongly attracted to self-regulating stick-slip cycles, although this self-regulating behavior can be bypassed on the way to runaway behavior if the initial state is too far from equilibrium.
21 CFR 886.4155 - Scleral plug.
Code of Federal Regulations, 2014 CFR
2014-04-01
... stainless steel with or without a gold, silver, or titanium coating. The special controls for the surgical grade stainless steel scleral plug (with or without a gold, silver, or titanium coating) are: (i) The... titanium coating). The special controls for scleral plugs made of other materials are: (i) The device must...
78 FR 70395 - Buy America Waiver Notification
Federal Register 2010, 2011, 2012, 2013, 2014
2013-11-25
...--light, medium, and heavy duty plug-in battery electric and compressed natural gas vehicles by Chicago..., medium, and heavy duty plug-in battery electric and compressed natural gas vehicles by Chicago DOT. In...--light, medium, and heavy duty plug-in battery electric and compressed natural gas vehicles ( http://www...
Kiffer, Micah S.; Tentarelli, Stephen Clyde
2016-02-09
Excess flow shutoff valve comprising a valve body, a valve plug, a partition, and an activation component where the valve plug, the partition, and activation component are disposed within the valve body. A suitable flow restriction is provided to create a pressure difference between the upstream end of the valve plug and the downstream end of the valve plug when fluid flows through the valve body. The pressure difference exceeds a target pressure difference needed to activate the activation component when fluid flow through the valve body is higher than a desired rate, and thereby closes the valve.
Wade, Elman E.
1978-01-01
A lifting, rotating and sealing apparatus for nuclear reactors utilizing rotating plugs above the nuclear reactor core. This apparatus permits rotation of the plugs to provide under the plug refueling of a nuclear core. It also provides a means by which positive top core holddown can be utilized. Both of these operations are accomplished by means of the apparatus lifting the top core holddown structure off the nuclear core while stationary, and maintaining this structure in its elevated position during plug rotation. During both of these operations, the interface between the rotating member and its supporting member is sealingly maintained.
Low power integrated pumping and valving arrays for microfluidic systems
Krulevitch, Peter A [Pleasanton, CA; Benett, William J [Livermore, CA; Rose, Klint A [Livermore, CA; Hamilton, Julie [Tracy, CA; Maghribi, Mariam [Davis, CA
2006-04-11
Low power integrated pumping and valving arrays which provide a revolutionary approach for performing pumping and valving approach for performing pumping and valving operations in microfabricated fluidic systems for applications such as medical diagnostic microchips. Traditional methods rely on external, large pressure sources that defeat the advantages of miniaturization. Previously demonstrated microfabrication devices are power and voltage intensive, only function at sufficient pressure to be broadly applicable. This approach integrates a lower power, high-pressure source with a polymer, ceramic, or metal plug enclosed within a microchannel, analogous to a microsyringe. When the pressure source is activated, the polymer plug slides within the microchannel, pumping the fluid on the opposite side of the plug without allowing fluid to leak around the plug. The plugs also can serve as microvalves.
Molten tin reprocessing of spent nuclear fuel elements. [Patent application; continuous process
Heckman, R.A.
1980-12-19
A method and apparatus for reprocessing spent nuclear fuel is described. Within a containment vessel, a solid plug of tin and nitride precipitates supports a circulating bath of liquid tin therein. Spent nuclear fuel is immersed in the liquid tin under an atmosphere of nitrogen, resulting in the formation of nitride precipitates. The layer of liquid tin and nitride precipitates which interfaces the plug is solidified and integrated with the plug. Part of the plug is melted, removing nitride precipitates from the containment vessel, while a portion of the plug remains solidified to support te liquid tin and nitride precipitates remaining in the containment vessel. The process is practiced numerous times until substantially all of the precipitated nitrides are removed from the containment vessel.
Wade, Elman E.
1979-01-01
A nuclear reactor including two rotatable plugs and a positive top core holddown structure. The top core holddown structure is divided into two parts: a small core cover, and a large core cover. The small core cover, and the upper internals associated therewith, are attached to the small rotating plug, and the large core cover, with its associated upper internals, is attached to the large rotating plug. By so splitting the core holddown structures, under-the-plug refueling is accomplished without the necessity of enlarging the reactor pressure vessel to provide a storage space for the core holddown structure during refueling. Additionally, the small and large rotating plugs, and their associated core covers, are arranged such that the separation of the two core covers to permit rotation is accomplished without the installation of complex lifting mechanisms.
Post-stenotic plug-like jet with a vortex ring demonstrated by 4D flow MRI.
Kim, Guk Bae; Ha, Hojin; Kweon, Jihoon; Lee, Sang Joon; Kim, Young-Hak; Yang, Dong Hyun; Kim, Namkug
2016-05-01
To investigate the details of the flow structure of a plug-like jet that had a vortex ring in pulsatile stenotic phantoms using 4D flow MRI. Pulsatile Newtonian flows in two stenotic phantoms with 50% and 75% reductions in area were scanned by 4D flow MRI. Blood analog working fluid was circulated via the stenotic phantom using a pulsatile pump at a constant pulsating frequency of 1Hz. The velocity and vorticity fields of the plug-like jet with a vortex ring were quantitatively analyzed in the spatial and temporal domains. Pulsatile stenotic flow showed a plug-like jet at the specific stenotic degree of 50% in our pulsatile waveform design. This plug-like jet was found at the decelerating period in the post-stenotic region of 26.4mm (1.2 D). It revealed a vortex ring structure with vorticity strength in the range of ±100s(-1). We observed a plug-like jet with a vortex ring in pulsatile stenotic flow by in vitro visualization using 4D flow MRI. In this plug-like jet, the local fastest flow region occurred at the post-systole phase in the post-stenotic region, which was distinguishable from a typical stenotic jet flow at systole phase. Copyright © 2015 Elsevier Inc. All rights reserved.
Lin, Yun-Ta; Liu, Yu-Wei; Cheng, Yi-Jie; Huang, Hsi-Ya
2010-07-01
In this study, an MEEKC was used to detect and analyze nine sulfonamide antibiotics. Owing to an insufficient sensitivity of on-column UV detection, a field-amplified sample injection, successive anion- and cation-selective injection, was used for the on-line concentration of the nine antibiotics. In the successive anion- and cation-selective injection mode, a leading water plug was introduced prior to anion injection, and then an acidic plug followed by a terminal water plug had to be used before subsequent cation injection. The results indicated some sulfonamides (sulfamonomethoxine, sulfamethazine, sulfamerazine and sulfadiazine) were determined as split signals in pairs, and this was likely due to the use of a longer acid plug (360 s) which caused the sulfonamide anions and cations to be stacked in two distinct zones of the leading water and acid plugs. Meanwhile, all the sulfonamides that were introduced either by anion or cation injection were stacked within the leading water plug when a shorter acid plug (210 s) was used. As a result, the nine sulfonamides were determined as single and symmetrical peaks with low LODs (0.9-4.2 microg/L). Furthermore, the MEEKC method was successfully applied for the detection of trace sulfonamide residues in several food and water samples.
Termination of flat conductor cable to NASA/MSFC plugs
NASA Technical Reports Server (NTRS)
Angele, W.
1972-01-01
Data, supplemented with artwork, are presented on the major steps involved with terminating flat conductor cable (FCC) to MSFC's FCC plugs. Cable and shield preparation steps include material cutting, insulation stripping, and plating of exposed conductors. Methods and equipment required to terminate FCC to each of four MSFC plugs are described.
40 CFR 146.10 - Plugging and abandoning Class I, II, III, IV, and V wells.
Code of Federal Regulations, 2010 CFR
2010-07-01
... (CONTINUED) WATER PROGRAMS (CONTINUED) UNDERGROUND INJECTION CONTROL PROGRAM: CRITERIA AND STANDARDS General... of drinking water. The Director may allow Class III wells to use other plugging materials if the... sources of drinking water. (2) Placement of the cement plugs shall be accomplished by one of the following...
Plug-In Tutor Agents: Still Pluggin'
ERIC Educational Resources Information Center
Ritter, Steven
2016-01-01
"An Architecture for Plug-in Tutor Agents" (Ritter and Koedinger 1996) proposed a software architecture designed around the idea that tutors could be built as plug-ins for existing software applications. Looking back on the paper now, we can see that certain assumptions about the future of software architecture did not come to be, making…
Smith and Navistar Electric and Plug-In Hybrid Vehicle Testing |
plug-in hybrid electric vehicles operated by a variety of companies in diverse climates across the plug-in hybrid electric drive systems in medium-duty trucks operating in fleet service across the nation. U.S. companies agreeing to participate in this evaluation project received funding from the
NREL Validates Plug-In Hybrid Truck for Pacific Gas and Electric Company |
Energy Systems Integration Facility | NREL Pacific Gas and Electric Company NREL Validates Plug -In Hybrid Truck for Pacific Gas and Electric Company NREL is evaluating and analyzing a Pacific Gas and Electric Company (PG&E) plug-in hybrid electric utility truck developed by Efficient
Free-jet acoustic investigation of high-radius-ratio coannular plug nozzles
NASA Technical Reports Server (NTRS)
Knott, P. R.; Janardan, B. A.; Majjigi, R. K.; Bhutiani, P. K.; Vogt, P. G.
1984-01-01
The experimental and analytical results of a scale model simulated flight acoustic exploratory investigation of high radius ratio coannular plug nozzles with inverted velocity and temperature profiles are summarized. Six coannular plug nozzle configurations and a baseline convergent conical nozzle were tested for simulated flight acoustic evaluation. The nozzles were tested over a range of test conditions that are typical of a Variable Cycle Engine for application to advanced high speed aircraft. It was found that in simulate flight, the high radius ratio coannular plug nozzles maintain their jet noise and shock noise reduction features previously observed in static testing. The presence of nozzle bypass struts will not significantly affect the acousticn noise reduction features of a General Electric type nozzle design. A unique coannular plug nozzle flight acoustic spectral prediction method was identified and found to predict the measured results quite well. Special laser velocimeter and acoustic measurements were performed which have given new insights into the jet and shock noise reduction mechanisms of coannular plug nozzles with regard to identifying further benificial research efforts.
Joule-Thomson valves for long term service in space cryocoolers
NASA Technical Reports Server (NTRS)
Lester, J. M.; Benedict, B.
1985-01-01
Joule-Thomson valves for small cryocoolers have throttling passages on the order of 0.1 millimeter in diameter. Consequently, they can become plugged easily and stop the operation of the cooler. Plugging can be caused by solid particles, liquids or gases. Plugging is usually caused by the freezing of contaminant gases from the process stream. In small open loop coolers and in closed loop coolers where periodic maintenance is allowed, the problem is overcome by using careful assembly techniques, pure process gases, warm filters and cold adsorbers. A more thorough approach is required for closed loop cryocoolers which must operate unattended for long periods. This paper presents the results of an effort to solve this problem. The causes of plugging are examined, and various ways to eliminate plugging are discussed. Finally, the development of a J-T defroster is explained. It is concluded that a combination of preventive measures and a defroster will reduce the chance of cooler failure by plugging to such a degree that J-T coolers can be used for long term space missions.
Damage Tolerance Assessment of Friction Pull Plug Welds in an Aluminum Alloy
NASA Technical Reports Server (NTRS)
McGill, Preston; Burkholder, Jonathan
2012-01-01
Friction stir welding is a solid state welding process used in the fabrication of cryogenic propellant tanks. Self-reacting friction stir welding is one variation of the friction stir weld process being developed for manufacturing tanks. Friction pull plug welding is used to seal the exit hole that remains in a circumferential self-reacting friction stir weld. A friction plug weld placed in a self-reacting friction stir weld results in a non-homogenous weld joint where the initial weld, plug weld, their respective heat affected zones and the base metal all interact. The welded joint is a composite plastically deformed material system with a complex residual stress field. In order to address damage tolerance concerns associated with friction plug welds in safety critical structures, such as propellant tanks, nondestructive inspection and proof testing may be required to screen hardware for mission critical defects. The efficacy of the nondestructive evaluation or the proof test is based on an assessment of the critical flaw size. Test data relating residual strength capability to flaw size in an aluminum alloy friction plug weld will be presented.
Holland, Roberto; Manne, Luciana Noronha; de Souza, Valdir; Murata, Sueli Satomi; Dezan Júnior, Eloi
2007-01-01
The purpose of this study was to evaluate the influence of coronal leakage on the healing of dogs' periapical tissues after root canal filling, post space preparation and protection or not with a temporary sealer plug. Forty root canals of dogs' teeth were instrumented and filled by the lateral condensation technique with gutta-percha points and Endomethasone or CRCS sealers. After post space preparation, the remaining filling material was protected or not with a plug of temporary Coltosol sealer and exposed to the oral environment for 90 days. Thereafter, the animals were sacrificed and the specimens were removed and prepared for histomorphological and histobacteriological analysis. The findings revealed 35% of microbial leakage in the groups without plugs and 15% of leakage in the groups with plugs. Statistical analysis showed that the use of a Coltosol plug improved significantly the histomorphological results regardless of the type of root canal sealer (p=0.05) and that CRCS and Endomethasone sealers showed similar results (p>0.05).
Large discharge-volume, silent discharge spark plug
Kang, Michael
1995-01-01
A large discharge-volume spark plug for providing self-limiting microdischarges. The apparatus includes a generally spark plug-shaped arrangement of a pair of electrodes, where either of the two coaxial electrodes is substantially shielded by a dielectric barrier from a direct discharge from the other electrode, the unshielded electrode and the dielectric barrier forming an annular volume in which self-terminating microdischarges occur when alternating high voltage is applied to the center electrode. The large area over which the discharges occur, and the large number of possible discharges within the period of an engine cycle, make the present silent discharge plasma spark plug suitable for use as an ignition source for engines. In the situation, where a single discharge is effective in causing ignition of the combustible gases, a conventional single-polarity, single-pulse, spark plug voltage supply may be used.
Engaging Tenants in Reducing Plug Load Energy Use
DOE Office of Scientific and Technical Information (OSTI.GOV)
Schantz, Marta; Langner, Rois
Plug and Process Loads (PPLs) account for an increasingly large percentage of commercial building energy use in the U.S. due to the rising number of energy intensive plug-in devices. In addition, buildings are becoming more and more efficient and plug load energy use has become an increasingly pertinent component to achieving aggressive energy targets and netzero energy status. For multi-tenant buildings, controlling plug loads in tenant spaces can be a significant challenge. Luckily, there are a number of PPL reduction strategies, best practices, and lessons learned from numerous commercial real estate and higher education leaders who have successfully engaged buildingmore » occupants and tenants in reducing PPL energy use. This paper provides actionable PPL reduction strategies and best practices that building owners and managers can immediately apply to their own buildings.« less
Bailey, Tom A.
1983-01-01
The reliability, reproducibility, and usefulness of three screening methods -- the cellophane transfer, the agar plug transfer, and the agar dilution -- to screen aquatic fungicides were evaluated. Achlya flagellata and Saprolegnia hypogyna were exposed to 1, 10, and 100 mg/L of malachite green to test each method. The cellophane transfer and agar plug transfer techniques had similar reliability and reproducibility in rating fungicidal activity, and were both superior to the agar dilution technique. The agar plug transfer and agar dilution techniques adequately projected in vivo activity of malachite green, but the cellophane transfer technique overestimated its activity. Overall, the agar plug transfer technique most accurately rated the activity of malachite green and was the easiest test to perform. It therefore appears to be the method of choice for testing aquatic fungicides.
Surface sampling concentration and reaction probe
Van Berkel, Gary J; Elnaggar, Mariam S
2013-07-16
A method of analyzing a chemical composition of a specimen is described. The method can include providing a probe comprising an outer capillary tube and an inner capillary tube disposed co-axially within the outer capillary tube, where the inner and outer capillary tubes define a solvent capillary and a sampling capillary in fluid communication with one another at a distal end of the probe; contacting a target site on a surface of a specimen with a solvent in fluid communication with the probe; maintaining a plug volume proximate a solvent-specimen interface, wherein the plug volume is in fluid communication with the probe; draining plug sampling fluid from the plug volume through the sampling capillary; and analyzing a chemical composition of the plug sampling fluid with an analytical instrument. A system for performing the method is also described.
Surface sampling concentration and reaction probe with controller to adjust sampling position
Van Berkel, Gary J.; ElNaggar, Mariam S.
2016-07-19
A method of analyzing a chemical composition of a specimen is described. The method can include providing a probe comprising an outer capillary tube and an inner capillary tube disposed co-axially within the outer capillary tube, where the inner and outer capillary tubes define a solvent capillary and a sampling capillary in fluid communication with one another at a distal end of the probe; contacting a target site on a surface of a specimen with a solvent in fluid communication with the probe; maintaining a plug volume proximate a solvent-specimen interface, wherein the plug volume is in fluid communication with the probe; draining plug sampling fluid from the plug volume through the sampling capillary; and analyzing a chemical composition of the plug sampling fluid with an analytical instrument. A system for performing the method is also described.
Integrated fountain effect pump device for fluid management at low gravity
NASA Technical Reports Server (NTRS)
Yuan, S. W. K.; Frank, D. J.
1988-01-01
A new device for fluid management at low gravity is described. The system is basically the same as the enclosed capillary device using screens, in which the screens along the gallery channels are replaced by porous plugs which are responsible for both the fluid retention and pumping of He II; in this device, no downstream pump is needed. The plugs in contact with liquid He on both sides act as a fountain-effect pumps (FEPs), while plugs exposed to vapor on one side behave as vapor-liquid phase separators (VLPSs). The total net rate of He II transfer into the receiving tank equals the mass flow rate through the FEP plugs minus the liquid loss from the VLPS plugs. The results of the performance analysis of this integrated FEP device are presented together with its schematic diagram.
Porous plug for Gravity Probe B
NASA Astrophysics Data System (ADS)
Wang, Suwen; Everitt, C. W. Francis; Frank, David J.; Lipa, John A.; Muhlfelder, Barry F.
2015-11-01
The confinement of superfluid helium for a Dewar in space poses a unique challenge due to its propensity to minimize thermal gradients by essentially viscous-free counterflow. This poses the risk of losing liquid through a vent pipe, reducing the efficiency of the cooling process. To confine the liquid helium in the Gravity Probe B (GP-B) flight Dewar, a porous plug technique was invented at Stanford University. Here, we review the history of the porous plug and its development, and describe the physics underlying its operation. We summarize a few missions that employed porous plugs, some of which preceded the launch of GP-B. The design, manufacture and flight performance of the GP-B plug are described, and its use resulted in the successful operation of the 2441 l flight Dewar on-orbit for 17.3 months.
Ford Plug-In Project: Bringing PHEVs to Market Demonstration and Validation Project
DOE Office of Scientific and Technical Information (OSTI.GOV)
D'Annunzio, Julie; Slezak, Lee; Conley, John Jason
2014-03-26
This project is in support of our national goal to reduce our dependence on fossil fuels. By supporting efforts that contribute toward the successful mass production of plug-in hybrid electric vehicles, our nation’s transportation-related fuel consumption can be offset with energy from the grid. Over four and a half years ago, when this project was originally initiated, plug-in electric vehicles were not readily available in the mass marketplace. Through the creation of a 21 unit plug-in hybrid vehicle fleet, this program was designed to demonstrate the feasibility of the technology and to help build cross-industry familiarity with the technology andmore » interface of this technology with the grid. Ford Escape PHEV Demonstration Fleet 3 March 26, 2014 Since then, however, plug-in vehicles have become increasingly more commonplace in the market. Ford, itself, now offers an all-electric vehicle and two plug-in hybrid vehicles in North America and has announced a third plug-in vehicle offering for Europe. Lessons learned from this project have helped in these production vehicle launches and are mentioned throughout this report. While the technology of plugging in a vehicle to charge a high voltage battery with energy from the grid is now in production, the ability for vehicle-to-grid or bi-directional energy flow was farther away than originally expected. Several technical, regulatory and potential safety issues prevented progressing the vehicle-to-grid energy flow (V2G) demonstration and, after a review with the DOE, V2G was removed from this demonstration project. Also proving challenging were communications between a plug-in vehicle and the grid or smart meter. While this project successfully demonstrated the vehicle to smart meter interface, cross-industry and regulatory work is still needed to define the vehicle-to-grid communication interface.« less
Paterson, Kade L; Hinman, Rana S; Metcalf, Ben R; Bennell, Kim L; Wrigley, Tim V
2017-01-01
Understanding how kinematic multi-segment foot modelling influences the utility of Plug-in-Gait calculations of the knee adduction moment (KAM) during shod walking is relevant to knee osteoarthritis (OA). Multi-segment foot markers placed on the skin through windows cut in to the shoe provide a more accurate representation of foot mechanics than the traditional marker set used by Plug-in-Gait, which uses fewer markers, placed on the shoe itself. We aimed to investigate whether Plug-in-Gait calculation of the KAM differed when using a kinematic multi-segment foot model compared to the traditional Plug-in-Gait marker set. Twenty people with medial knee OA underwent gait analysis in two test conditions: i) Plug-in-Gait model with its two standard foot markers placed on the shoes and; ii) Plug-in-Gait with the heel marker virtualised from a modified-Oxford Foot Model where 8 ft markers were placed on the skin through windows cut in shoe uppers. Outcomes were the peak KAM, KAM impulse and other knee kinetic and kinematic variables. There were no differences ( P > 0.05) in any gait variables between conditions. Excellent agreement was found for all outcome variables, with high correlations ( r > 0.88-0.99, P < 0.001), narrow limits of agreement and no proportional bias ( R 2 = 0.03-0.14, P > 0.05). The mean difference and 95% confidence intervals for peak KAM were also within the minimal detectable change range demonstrating equivalence. Plug-in-Gait calculations of the KAM are not altered when using a kinematic multi-segment foot marker model with skin markers placed through windows cut in to the shoe, instead of the traditional marker set placed on top of shoes. Researchers may be confident that applying either foot model does not change the calculation of the KAM using Plug-in-Gait.
Well sealing via thermite reactions
Lowry, William Edward; Dunn, Sandra Dalvit
2016-11-15
A platform is formed in a well below a target plug zone by lowering a thermite reaction charge into the well and igniting it, whereby the products of the reaction are allowed to cool and expand to form a platform or support in the well. A main thermite reaction charge is placed above the platform and ignited to form a main sealing plug for the well. In some embodiments an upper plug is formed by igniting an upper thermite reaction charge above the main thermite reaction charge. The upper plug confines the products of ignition of the main thermite reaction charge.
Zhao, S C
1990-05-01
A non-incision method of vas occlusion based on the percutaneous injection of polyurethane elastomer solution to form plugs is described. The results are based on clinical experience in 12,000 men in which only 56 cases of minor complications were recorded. Follow-up of 500 men for up to 3 years demonstrated an azoospermia rate of 98%. Plugs have been removed from 86 men and, to date, 51 have made their wives pregnant. In those from which the plugs have been removed for more than 1 year (n = 31), the pregnancy rate is 100%.
Electronic-type vacuum gauges with replaceable elements
Edwards, Jr., David
1984-01-01
In electronic devices for measuring pressures in vacuum systems, the metal elements which undergo thermal deterioration are made readily replaceable by making them parts of a simple plug-in unit. Thus, in ionization gauges, the filament and grid or electron collector are mounted on the novel plug-in unit. In thermocouple pressure gauges, the heater and attached thermocouple are mounted on the plug-in unit. Plug-in units have been designed to function, alternatively, as ionization gauge and as thermocouple gauge, thus providing new gauges capable of measuring broader pressure ranges than is possible with either an ionization gauge or a thermocouple gauge.
LST CGM Generator and Viewer Final Report CRADA No. TSB-1558-98
DOE Office of Scientific and Technical Information (OSTI.GOV)
Vickers, Don; Larson, Don
The purpose of this project was to jointly develop and test a software plug-in that would convert native Pro /ENGINEER digital engineering drawings to Computer Graphics Metafile (CGM) format. If it was not feasible to convert the Pro/ENGINEER files, we planned to develop and test a similar conversion of native AutoCAD engineering drawings to CGM. CGM viewer plug-ins were developed as needed. There were four main tasks in this project: 1. Requirements for CGM Plug-in 2. Product Evaluation 3. Product Development Feasibility Study 4. Developing a "Plug-In" Application.
Quantum well infrared photodetectors (QWIP) with selectively regrown N-GaAs plugs
NASA Astrophysics Data System (ADS)
Matsukura, Yusuke; Nishino, Hironori; Tanaka, Hitoshi; Fujii, Toshio
2001-10-01
We fabricated the GaAs/AlGaAs Quantum Well Infrared Photo detector (QWIP) focal plane array with selectively re-grown N- GaAs interconnection plugs and demonstrated its device operation, in order to establish the technology to obtain both complex device functions and device manufacturability. MBE (Molecular Beam Epitaxy) grown QWIP MQW wafers were covered with SiON and SiNx mask films to obtain selectivity of the re-growth process. N-GaAs plugs were re-grown selectively with low-pressure MOCVD (Metal-Organic Chemical Vapor Deposition) with AsH3 and Dimethylgalliumchloride as precursors, only on the bottom surfaces of the holes for the interconnection to extract the electrodes from the underlying epilayer. Cross- sectional SEM observation revealed that the feature of the re- grown N-GaAs plugs was triangular, rather than rectangular as expected. The reason for this discrepancy is not yet clear. The electrical contact between the epilayer and re-grown N- GaAs plug was 'ohmic-like,' without any trace of interfacial barrier. The Current-Voltage characteristics of the fabricated QWIP device showed no tangible leakage current between the N- GaAs plug and device structure, indicating that electrical insulation between the N-GaAs plugs and device structure was sufficient. Fabricated devices were successfully operated as a hybrid focal plane array, indicating the selective re-growth was a promising technique to realize complex QWIP based devices.
Barmack, N H; Pettorossi, V E
1988-08-01
The influence of unilateral plugs of the left horizontal semicircular canal (LHC plugs) of rabbits on the development and compensation of asymmetric eye movements evoked by horizontal vestibular stimulation was studied. LHC plugs caused an immediate reduction of 50-65% in the gain of the horizontal vestibuloocular reflex (HVOR). This reduction in gain was achieved without altering the symmetry of the HVOR, and was accompanied by a change in the axial alignment of eye movements evoked by vestibular stimulation about the vertical (HVOR) and longitudinal (VVOR) axes. Postoperative asymmetry of eye movements developed 12-48 hr after the plugging operation. The development of asymmetry was reduced if the rabbit was restrained for 24 hr, thereby minimizing vestibular stimulation following the plugging operation. Over a 3-4 week period, the normal symmetry of eye movements was restored and the axial alignments of the HVOR and VVOR returned to the preoperative values. The gain of the HVOR did not recover. The horizontal cervicoocular reflex (HCOR) was examined before the plugging operation and after compensation of asymmetry was complete. The gain and phase of the HCOR were not altered. A relatively simple set of explanations at a cellular level is proposed to account for the induction and compensation of asymmetric eye movements following a unilateral plug of the horizontal semicircular canal.
DOE Office of Scientific and Technical Information (OSTI.GOV)
ElNaggar, Mariam S.; Van Berkel, Gary J.
2011-08-10
The recently discovered sample plug formation and injection operational mode of a continuous flow, coaxial tube geometry, liquid microjunction surface sampling probe (LMJ-SSP) (J. Am. Soc. Mass Spectrom, 2011) was further characterized and applied for concentration and mixing of analyte extracted from multiple areas on a surface and for nanoliter-scale chemical reactions of sampled material. A transparent LMJ-SSP was constructed and colored analytes were used so that the surface sampling process, plug formation, and the chemical reactions could be visually monitored at the sampling end of the probe before being analyzed by mass spectrometry of the injected sample plug. Injectionmore » plug peak widths were consistent for plug hold times as long as the 8 minute maximum attempted (RSD below 1.5%). Furthermore, integrated injection peak signals were not significantly different for the range of hold times investigated. The ability to extract and completely mix individual samples within a fixed volume at the sampling end of the probe was demonstrated and a linear mass spectral response to the number of equivalent analyte spots sampled was observed. Lastly, using the color and mass changing chemical reduction of the redox dye 2,6-dichlorophenol-indophenol with ascorbic acid, the ability to sample, concentrate, and efficiently run reactions within the same plug volume within the probe was demonstrated.« less
The Environmental Technology Verification report discusses the technology and performance of the Plug Power SU1 Fuel Cell System manufactured by Plug Power. The SU1 is a proton exchange membrane fuel cell that requires hydrogen (H2) as fuel. H2 is generally not available, so the ...
40 CFR 600.302-12 - Fuel economy label-general provisions.
Code of Federal Regulations, 2012 CFR
2012-07-01
... includes hybrid electric vehicles that do not have plug-in capability. Include a logo corresponding to the..., include a fuel pump logo and the designation “E85”. (iii) Identify plug-in hybrid electric vehicles as... fuel pump logo as specified in paragraph (b)(3)(i) of this section and an electric plug logo to the...
40 CFR 600.302-12 - Fuel economy label-general provisions.
Code of Federal Regulations, 2014 CFR
2014-07-01
... includes hybrid electric vehicles that do not have plug-in capability. Include a logo corresponding to the..., include a fuel pump logo and the designation “E85”. (iii) Identify plug-in hybrid electric vehicles as... fuel pump logo as specified in paragraph (b)(3)(i) of this section and an electric plug logo to the...
46 CFR 52.01-50 - Fusible plugs (modifies A-19 through A-21).
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 2 2011-10-01 2011-10-01 false Fusible plugs (modifies A-19 through A-21). 52.01-50 Section 52.01-50 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING POWER BOILERS General Requirements § 52.01-50 Fusible plugs (modifies A-19 through A-21). (a) All...
46 CFR 52.01-50 - Fusible plugs (modifies A-19 through A-21).
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 2 2012-10-01 2012-10-01 false Fusible plugs (modifies A-19 through A-21). 52.01-50 Section 52.01-50 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING POWER BOILERS General Requirements § 52.01-50 Fusible plugs (modifies A-19 through A-21). (a) All...
46 CFR 52.01-50 - Fusible plugs (modifies A-19 through A-21).
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 2 2010-10-01 2010-10-01 false Fusible plugs (modifies A-19 through A-21). 52.01-50 Section 52.01-50 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING POWER BOILERS General Requirements § 52.01-50 Fusible plugs (modifies A-19 through A-21). (a) All...
46 CFR 52.01-50 - Fusible plugs (modifies A-19 through A-21).
Code of Federal Regulations, 2014 CFR
2014-10-01
... 46 Shipping 2 2014-10-01 2014-10-01 false Fusible plugs (modifies A-19 through A-21). 52.01-50 Section 52.01-50 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING POWER BOILERS General Requirements § 52.01-50 Fusible plugs (modifies A-19 through A-21). (a) All...
Mechanics Model of Plug Welding
NASA Technical Reports Server (NTRS)
Zuo, Q. K.; Nunes, A. C., Jr.
2015-01-01
An analytical model has been developed for the mechanics of friction plug welding. The model accounts for coupling of plastic deformation (material flow) and thermal response (plastic heating). The model predictions of the torque, energy, and pull force on the plug were compared to the data of a recent experiment, and the agreements between predictions and data are encouraging.
Alternative Fuels Data Center: North Carolina Airport Advances With Plug-In
Electric BusesA> North Carolina Airport Advances With Plug-In Electric Buses to someone by E-mail passengers with plug-in hybrid electric buses. For information about this project, contact Centralina Clean . Provided by Maryland Public Television Related Videos Photo of a car Electric Vehicles Charge up at State
Alternative Fuels Data Center: Hybrid and Plug-In Electric Vehicle
Emissions Data Sources and Assumptions Hybrid and Plug-In Electric Vehicle Emissions Data Sources and Assumptions to someone by E-mail Share Alternative Fuels Data Center: Hybrid and Plug-In Electric Vehicle Emissions Data Sources and Assumptions on Facebook Tweet about Alternative Fuels Data
30 CFR 250.1712 - What information must I submit before I permanently plug a well or zone?
Code of Federal Regulations, 2010 CFR
2010-07-01
...) Recent well test data and pressure data, if available; (c) Maximum possible surface pressure, and how it... permanently plug a well or zone? 250.1712 Section 250.1712 Mineral Resources MINERALS MANAGEMENT SERVICE... Decommissioning Activities Permanently Plugging Wells § 250.1712 What information must I submit before I...
Fluid Mechanics of Capillary-Elastic Instabilities in Microgravity Environment
NASA Technical Reports Server (NTRS)
Grotberg, James B.
2002-01-01
The aim of this project is to investigate the closure and reopening of lung airways due to surface tension forces, coupled with airway elasticity. Airways are liquid-lined, flexible tubes and closure of airways can occur by a Rayleigh instability of the liquid lining, or an instability of the elastic support for the airway as the surface tension of the air-liquid interface pulls the tube shut, or both. Regardless of the mechanism, the airway is closed because the liquid lining has created a plug that prevents axial gas exchange. In the microgravity environment, surface tension forces dominate lung mechanics and would lead to more prevalent, and more uniformly distributed air-way closure, thereby creating a potential for respiratory problems for astronauts. Once closed the primary option for reopening an airway is by deep inspiration. This maneuver will pull the flexible airways open and force the liquid plug to flow distally by the incoming air stream. Airway reopening depends to a large extent on this plug flow and how it may lead to plug rupture to regain the continuity of gas between the environment and the alveoli. In addition to mathematical modeling of plug flows in liquid-lined, flexible tubes, this work has involved benchtop studies of propagating liquid plugs down tube networks that mimic the human airway tree. We have extended the work to involve animal models of liquid plug propagation in rat lungs. The liquid is radio-opaque and x-ray video imaging is used to ascertain the movement and distribution of the liquid plugs so that comparisons to theory may be made. This research has other uses, such as the delivery of liquids or drugs into the lung that may be used for surfactant replacement therapy or for liquid ventilation.
Methodology for Mechanical Property Testing of Fuel Cladding Using a Expanded Plug Wedge Test
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jiang, Hao; Wang, Jy-An John
2014-01-01
An expanded plug method was developed earlier for determining the tensile properties of irradiated fuel cladding. This method tests fuel rod cladding ductility by utilizing an expandable plug to radially stretch a small ring of irradiated cladding material. The circumferential or hoop strain is determined from the measured diametrical expansion of the ring. A developed procedure is used to convert the load circumferential strain data from the ring tests into material pseudo-stress-strain curves, from which material properties of the cladding can be extracted. However, several deficiencies existed in this expanded-plug test that can impact the accuracy of test results, suchmore » as that the large axial compressive stress resulted from the expansion plug test can potentially induce the shear failure mode of the tested specimen. Moreover, highly nonuniform stress and strain distribution in the deformed clad gage section and significant compressive stresses, induced by bending deformation due to clad bulging effect, will further result in highly nonconservative estimates of the mechanical properties for both strength and ductility of the tested clad. To overcome the aforementioned deficiencies associated with the current expansion plug test, systematic studies have been conducted. By optimizing the specific geometry designs, selecting the appropriate material for the expansion plug, and adding new components into the testing system, a modified expansion plug testing protocol has been developed. A general procedure was also developed to determine the hoop stress in the tested ring specimen. A scaling factor, -factor, was used to convert the ring load Fring into hoop stress , and is written as _ = F_ring/tl , where t is the clad thickness and l is the clad length. The generated stress-strain curve agrees well with the associated tensile test data in both elastic and plastic deformation regions.« less
NASA Technical Reports Server (NTRS)
Knott, P. R.; Blozy, J. T.; Staid, P. S.
1981-01-01
The results of model scale parametric static and wind tunnel aerodynamic performance tests on unsuppressed coannular plug nozzle configurations with inverted velocity profile are discussed. The nozzle configurations are high-radius-ratio coannular plug nozzles applicable to dual-stream exhaust systems typical of a variable cycle engine for Advanced Supersonic Transport application. In all, seven acoustic models and eight aerodynamic performance models were tested. The nozzle geometric variables included outer stream radius ratio, inner stream to outer stream ratio, and inner stream plug shape. When compared to a conical nozzle at the same specific thrust, the results of the static acoustic tests with the coannular nozzles showed noise reductions of up to 7 PNdB. Extensive data analysis showed that the overall acoustic results can be well correlated using the mixed stream velocity and the mixed stream density. Results also showed that suppression levels are geometry and flow regulation dependent with the outer stream radius ratio, inner stream-to-outer stream velocity ratio and inner stream velocity ratio and inner stream plug shape, as the primary suppression parameters. In addition, high-radius ratio coannular plug nozzles were found to yield shock associated noise level reductions relative to a conical nozzle. The wind tunnel aerodynamic tests showed that static and simulated flight thrust coefficient at typical takeoff conditions are quite good - up to 0.98 at static conditions and 0.974 at a takeoff Mach number of 0.36. At low inner stream flow conditions significant thrust loss was observed. Using an inner stream conical plug resulted in 1% to 2% higher performance levels than nozzle geometries using a bent inner plug.
Unconventional nozzle tradeoff study. [space tug propulsion
NASA Technical Reports Server (NTRS)
Obrien, C. J.
1979-01-01
Plug cluster engine design, performance, weight, envelope, operational characteristics, development cost, and payload capability, were evaluated and comparisons were made with other space tug engine candidates using oxygen/hydrogen propellants. Parametric performance data were generated for existing developed or high technology thrust chambers clustered around a plug nozzle of very large diameter. The uncertainties in the performance prediction of plug cluster engines with large gaps between the modules (thrust chambers) were evaluated. The major uncertainty involves, the aerodynamics of the flow from discrete nozzles, and the lack of this flow to achieve the pressure ratio corresponding to the defined area ratio for a plug cluster. This uncertainty was reduced through a cluster design that consists of a plug contour that is formed from the cluster of high area ratio bell nozzles that have been scarfed. Light-weight, high area ratio, bell nozzles were achieved through the use of AGCarb (carbon-carbon cloth) nozzle extensions.
Iron Mountain Electromagnetic Results
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gail Heath
2012-07-01
Iron Mountain Mine is located seventeen miles northwest of Redding, CA. After the completion of mining in early 1960s, the mine workings have been exposed to environmental elements which have resulted in degradation in water quality in the surrounding water sheds. In 1985, the EPA plugged ore stoops in many of the accessible mine drifts in an attempt to restrict water flow through the mine workings. During this process little data was gathered on the orientation of the stoops and construction of the plugs. During the last 25 years, plugs have begun to deteriorate and allow acidic waters from themore » upper workings to flow out of the mine. A team from Idaho National Laboratory (INL) performed geophysical surveys on a single mine drift and 3 concrete plugs. The project goal was to evaluate several geophysical methods to determine competence of the concrete plugs and orientation of the stopes.« less
Investigation of Thrust and Drag Characteristics of a Plug-type Exhaust Nozzle
NASA Technical Reports Server (NTRS)
Hearth, Donald P; Gorton, Gerald C
1954-01-01
An investigation was conducted in the 8- by 6-foot supersonic wind tunnel on the external and internal characteristics of a plug-type exhaust nozzle. Two positions of the center plug, one simulating a convergent nozzle and the other a convergent-divergent nozzle, were investigated. Data were obtained at free-stream Mach numbers of 0.1, 0.6, 1.6, and 2.0 over a pressure-ratio range of 1 to 20 and angles of attack of zero and 8 degrees. Results of this investigation indicated that the plug nozzle had thrust-minus-drag performance over the entire pressure-ratio range comparable with equivalent conventional nozzles. The effect of the exhaust jet on the external aerodynamics was similar to results observed for conventional nozzles. In addition, the thrust characteristics were generally insensitive to external flow and good agreement was noted with data obtained on comparable plug nozzles in quiescent air.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Black, H.N.; Melton, L.L.
1966-01-04
A temporary plugging agent, fracturing fluid and/or channel sealing agent is introduced into a selected area of a formation. The water-gelled fluid agent contains sodium borate, sodium tetraborate, and borax. It also contains a chemical breaker such as benzotrichloride, benzylidene chloride, or benzyl chloride. The water-gelled fluid consists essentially of water and from about 1-3% by weight of water of a finely powdered water-soluble gum of the galactomannan class. The borate compound is included in an amount of about 10% by weight of the gum to delay the reaction with the gel and to form a rubbery jelly-like mass withmore » it. The fluid composition has a delaying solidifying action and after a given interval of time it forms a plug. After a predetermined time, acid is produced upon the hydrolysis of the breaker in the plug and removes the plug from the area.« less
Plug-Load Control and Behavioral Change Research in GSA Office Buildings
DOE Office of Scientific and Technical Information (OSTI.GOV)
Metzger, I.; Cutler, D.; Sheppy, M.
2012-10-01
The U.S. General Services Administration (GSA) owns and leases over 354 million square feet (ft2) of space in over 9,600 buildings [1]. GSA is a leader among federal agencies in aggressively pursuing energy efficiency (EE) opportunities for its facilities and installing renewable energy (RE) systems to provide heating, cooling, and power to these facilities. According to several energy assessments of GSA's buildings conducted by the National Renewable Energy Laboratory (NREL), plug-loads account for approximately 21% of the total electricity consumed within a standard GSA Region 3 office building. This study aims to provide insight on how to effectively manage plug-loadmore » energy consumption and attain higher energy and cost savings for plug-loads. As GSA improves the efficiency of its building stock, plug-loads will become an even greater portion of its energy footprint.« less
Elimination of toxicity from polyurethane foam plugs used for plant culture
NASA Technical Reports Server (NTRS)
Wheeler, R. M.; Schwartzkopf, S. H.; Tibbitts, T. W.; Langhans, R. W.
1985-01-01
Polyurethane foam plugs commonly are used as collars or supports to grow plants in solution culture. Despite their utility, these foam plugs can be quite toxic to plants, particularly to small seedlings. We have observed tissue injury in tests using plugs to support lettuce, red beet, and potato plants in solution culture. Typically, the injury is initiated on the hypocotyl or stem tissue in direct contact with the foam, and appears within 30 hr as a brownish discoloration on the tissue surface. This discoloration can be followed by complete collapse of affected tissue and eventual death of the seedling. When injury does not progress beyond surface browning, the seedling survives but growth is slowed. In this paper, we report on different treatments that can be used to remove the toxicity of these plugs so they can be used in plant research.
Waste isolation pilot plant (WIPP) borehole plugging program description
DOE Office of Scientific and Technical Information (OSTI.GOV)
Christensen, C.L.; Hunter, T.O.
1979-08-01
The tests and experiments described attempt to provide a mix of borehole (with limited access) and in-mine (with relatively unlimited access) environments in which assessment of the various issues involved can be undertaken. The Bell Canyon Test provides the opportunity to instrument and analyze a plug in a high pressure region. The Shallow Hole Test permits application of best techniques for plugging and then access to both the top and bottom of the plug for further analysis. The Diagnostic Test Hole permits recovery of bench scale size samples for analysis and establishes an in-borehole laboratory in which to conduct testingmore » and analysis in all strata from the surface into the salt horizon. The additional in mine experiments provide the opportunity to investigate in more detail specific effects on plugs in the salt region and allows evaluation of instrumentation systems.« less
2195 Aluminum-Copper-Lithium Friction Plug Welding Development
NASA Technical Reports Server (NTRS)
Takeshita, Rike P.; Hartley, Paula J.; Baker, Kent S.
1997-01-01
Technology developments and applications of friction plug welding is presented. This friction repair welding technology is being studied for implementation on the Space Transportation System's Super Light Weight External Tank. Single plug repairs will be used on a vast majority of weld defects, however, linear defects of up to several inches can be repaired by overlapping plug welds. Methods and results of tensile, bend, simulated service, surface crack tension and other tests at room and cryogenic temperatures is discussed. Attempts to implement Friction Plug Welding has led to both tool and process changes in an attempt to minimize expansive tooling and lengthy implementation times. Process control equipment and data storage methods intended for large scale production will also be addressed. Benefits include increased strength and toughness, decreased weld repair time, automated and highly reliable process, and a lower probability of having to re-repair defect locations.
The Losing Battle against Plug-and-Chug
ERIC Educational Resources Information Center
Kortemeyer, Gerd
2016-01-01
I think most physics teachers would agree that two important components of a proper solution to a numerical physics problem are to first figure out a final symbolic solution and to only plug in numbers in the end. However, in spite of our best efforts, this is not what the majority of students is actually doing. Instead, they tend to plug numbers…
Plug Your Users into Library Resources with OpenSearch Plug-Ins
ERIC Educational Resources Information Center
Baker, Nicholas C.
2007-01-01
To bring the library catalog and other online resources right into users' workspace quickly and easily without needing much more than a short XML file, the author, a reference and Web services librarian at Williams College, learned to build and use OpenSearch plug-ins. OpenSearch is a set of simple technologies and standards that allows the…
Hybrid and Plug-in Electric Vehicles
DOE Office of Scientific and Technical Information (OSTI.GOV)
None
2014-05-20
Hybrid and plug-in electric vehicles use electricity either as their primary fuel or to improve the efficiency of conventional vehicle designs. This new generation of vehicles, often called electric drive vehicles, can be divided into three categories: hybrid electric vehicles (HEVs), plug-in hybrid electric vehicles(PHEVs), and all-electric vehicles (EVs). Together, they have great potential to reduce U.S. petroleum use.
How Much Do Electric Cars Pollute? Depends on When and Where You Plug In |
News | NREL How Much Do Electric Cars Pollute? Depends on When and Where You Plug In How Much Do Electric Cars Pollute? Depends on When and Where You Plug In May 19, 2016 The transportation the potential for emissions reduction depends on when and where drivers charge their vehicles. The
LOX/Methane Main Engine Glow Plug Igniter Tests and Modeling
NASA Technical Reports Server (NTRS)
Breisacher, Kevin; Ajmani, Kumud
2009-01-01
Ignition data for tests with a LOX/methane igniter that utilized a glow plug as the ignition source are presented. The tests were conducted in a vacuum can with thermally conditioned (cold) hardware. Data showing the effects of glow plug geometry, type, and igniter operating conditions are discussed. Comparisons between experimental results and multidimensional, transient computer models are also made.
Shock-operated valve would automatically protect fluid systems
NASA Technical Reports Server (NTRS)
Branum, L. W.; Wells, G. H.
1966-01-01
Glandless valve shuts down high-pressure fluid systems when severe shock from an explosion or earthquake occurs. The valve uses a pendulum to support the valve closure plug in the open position. When jarred, the valve body is moved relative to the pendulum and the plug support is displaced, allowing the plug to seat and be held by spring pressure.
Electrically heated particulate matter filter with recessed inlet end plugs
Gonze, Eugene V [Pinckney, MI; Ament, Frank [Troy, MI
2012-02-21
A particulate matter (PM) filter includes filter walls having inlet ends and outlet ends. First adjacent pairs of the filter walls define inlet channels. Second adjacent pairs of the filter walls define outlet channels. Outlet end plugs are arranged in the inlet channels adjacent to the output ends. Inlet end plugs arranged in the outlet channels spaced from the inlet ends.
METHOD FOR MAKING FUEL ELEMENTS
Kates, L.W.; Campbell, R.W.; Heartel, R.H.W.
1960-08-01
A method is given for making zirconium-clad uranium wire. A tube of zirconium is closed with a zirconium plug, after which a chilled uranium core is inserted in the tube to rest against the plug. Additional plugs and cores are inserted alternately as desired. The assembly is then sheathed with iron, hot worked to the desired size, and the iron sheath removed.
NASA Technical Reports Server (NTRS)
Corbin, J.; Buras, D.
1986-01-01
Large holes in polyurethane foam insulation repaired reliably by simple method. Little skill needed to apply method, used for overhead repairs as well as for those in other orientations. Plug positioned in hole to be filled and held in place with mounting fixture. Fresh liquid foam injected through plug to bond it in place. As foam cures and expands, it displaces plug outward. Protrusion later removed.
Simulation on friction taper plug welding of AA6063-20Gr metal matrix composite
NASA Astrophysics Data System (ADS)
Hynes, N. Rajesh Jesudoss; Nithin, Abeyram M.
2016-05-01
Friction taper plug welding a variant of friction welding is useful in welding of similar and dissimilar materials. It could be used for joining of composites to metals in sophisticated aerospace applications. In the present work numerical simulation of friction taper plug welding process is carried out using finite element based software. Graphite reinforced AA6063 is modelled using the software ANSYS 15.0 and temperature distribution is predicted. Effect of friction time on temperature distribution is numerically investigated. When the friction time is increased to 30 seconds, the tapered part of plug gets detached and fills the hole in the AA6063 plate perfectly.
Petrenko, Serhiy Fedorovich
2013-01-15
A motorized valve has a housing having an inlet and an outlet to be connected to a pipeline, a saddle connected with the housing, a turn plug having a rod, the turn plug cooperating with the saddle, and a drive for turning the valve body and formed as a piezoelectric drive, the piezoelectric drive including a piezoelectric generator of radially directed standing acoustic waves, which is connected with the housing and is connectable with a pulse current source, and a rotor operatively connected with the piezoelectric generator and kinematically connected with the rod of the turn plug so as to turn the turn plug when the rotor is actuated by the piezoelectric generator.
Electronic-type vacuum gauges with replaceable elements
Edwards, D. Jr.
1984-09-18
In electronic devices for measuring pressures in vacuum systems, the metal elements which undergo thermal deterioration are made readily replaceable by making them parts of a simple plug-in unit. Thus, in ionization gauges, the filament and grid or electron collector are mounted on the novel plug-in unit. In thermocouple pressure gauges, the heater and attached thermocouple are mounted on the plug-in unit. Plug-in units have been designed to function, alternatively, as ionization gauge and as thermocouple gauge, thus providing new gauges capable of measuring broader pressure ranges than is possible with either an ionization gauge or a thermocouple gauge. 5 figs.
NASA Technical Reports Server (NTRS)
Nosek, S. M.; Straight, D. M.
1976-01-01
Plug nozzle film cooling data were obtained downstream of a slot located at 42 percent of the total plug length on a J-85 engine. Film cooling reduced the aft end wall temperature as much as 150 K, reduced total pressure loss in the upstream convection cooling passages by 50 percent, and reduced estimated compressor bleed flow requirement by 14 percent compared to an all convectively cooled nozzle. Shock waves along the plug surface strongly influenced temperature distributions on both convection and film cooled portions. The effect was most severe at nozzle pressure ratios below 10 where adverse pressure gradients were most severe.
Fiber Optic Temperature Sensor Insert for High Temperature Environments
NASA Technical Reports Server (NTRS)
Black, Richard James (Inventor); Costa, Joannes M. (Inventor); Moslehi, Behzad (Inventor); Zarnescu, Livia (Inventor)
2017-01-01
A thermal protection system (TPS) test plug has optical fibers with FBGs embedded in the optical fiber arranged in a helix, an axial fiber, and a combination of the two. Optionally, one of the optical fibers is a sapphire FBG for measurement of the highest temperatures in the TPS plug. The test plug may include an ablating surface and a non-ablating surface, with an engagement surface with threads formed, the threads having a groove for placement of the optical fiber. The test plug may also include an optical connector positioned at the non-ablating surface for protection of the optical fiber during insertion and removal.
Liquid Therapy Delivery Models Using Microfluidic Airways
NASA Astrophysics Data System (ADS)
Mulligan, Molly K.; Grotberg, James B.; Waisman, Dan; Filoche, Marcel; Sznitman, Josué
2013-11-01
The propagation and break-up of viscous and surfactant-laden liquid plugs in the lungs is an active area of research in view of liquid plug installation in the lungs to treat a host of different pulmonary conditions. This includes Infant Respiratory Distress Syndrome (IRDS) the primary cause of neonatal death and disability. Until present, experimental studies of liquid plugs have generally been restricted to low-viscosity Newtonian fluids along a single bifurcation. However, these fluids reflect poorly the actual liquid medication therapies used to treat pulmonary conditions. The present work attempts to uncover the propagation, rupture and break-up of liquid plugs in the airway tree using microfluidic models spanning three or more generations of the bronchiole tree. Our approach allows the dynamics of plug propagation and break-up to be studied in real-time, in a one-to-one scale in vitro model, as a function of fluid rheology, trailing film dynamics and bronchial tree geometry. Understanding these dynamics are a first and necessary step to deliver more effectively boluses of liquid medication to the lungs while minimizing the injury caused to epithelial cells lining the lungs from the rupture of such liquid plugs.
Simulation of shear plugging through thin plates using the GRIM Eulerian hydrocode
NASA Astrophysics Data System (ADS)
Church, P.; Cornish, R.; Cullis, I.; Lynch, N.
2000-03-01
Ballistic experiments have been performed using aluminum spheres against 10-mm rolled homogenous armour (RHA), MARS270, MARS300, and titanium alloy plates to investigate the influence of the plugging mechanism on material properties. The experiments have measured the threshold for plug mass and velocity as well as the recovered aluminum sphere mass over a range of velocities. Some of the experiments have been simulated using the in-house second generation Eulerian hydrocode GRIM. The calculations feature advanced material algorithms derived from interrupted tensile testing techniques and a triaxial failure model derived from notched tensile tests over a range of strain rates and temperatures. The effect of mesh resolution on the results has been investigated and understood. The simulation results illustrate the importance of the constitutive model in the shear localization process and the subsequent plugging phenomena. The stress triaxiality is seen as the dominant feature in controlling the onset and subsequent propagation of the crack leading to the shear plug. The simulations have demonstrated that accurate numerics coupled with accurate constitutive and fracture algorithms can successfully reproduce the observed experimental features. However, extrapolation of the fracture data leads to the simulations overpredicting the plug damage. The reasons for this are discussed.
From catastrophic acceleration to deceleration of liquid plugs in prewetted capillary tubes
NASA Astrophysics Data System (ADS)
Magniez, Juan; Baudoin, Michael; Zoueshtiagh, Farzam; Lemac/Lics Team
2016-11-01
Liquid/gas flows in capillaries are involved in a multitude of systems including flow in porous media, petroleum extraction, imbibition of paper or flows in pulmonary airways in pathological conditions. Liquid plugs, witch compose the biphasic flows, can have a dramatic impact on patients with pulmonary obstructive diseases, since they considerably alter the circulation of air in the airways and thus can lead to severe breathing difficulties. Here, the dynamics of liquid plugs in prewetted capillary tube is investigated experimentally and theoretically, with a particular emphasis on the role of the prewetting films and of the driving condition (constant flow rate, constant pressure). For both driving conditions, the plugs can either experience a continuous increase or decrease of their size. While this phenomenon is regular in the case of imposed flow rate, a constant pressure head can lead to a catastrophic acceleration of the plug and eventually its rupture or a dramatic increase of the plug size. A theoretical model is proposed to explain the transition between theses two regimes. These results give a new insight on the critical pressure required for airways obstruction and reopening. IEMN, International Laboratory LEMAC/LICS, UMR CNRS 8520, University of Lille.
RCC Plug Repair Thermal Tools for Shuttle Mission Support
NASA Technical Reports Server (NTRS)
Rodriguez, Alvaro C.; Anderson, Brian P.
2010-01-01
A thermal math model for the Space Shuttle Reinforced Carbon-Carbon (RCC) Plug Repair was developed to increase the confidence in the repair entry performance and provide a real-time mission support tool. The thermal response of the plug cover plate, local RCC, and metallic attach hardware can be assessed with this model for any location on the wing leading edge. The geometry and spatial location of the thermal mesh also matches the structural mesh which allows for the direct mapping of temperature loads and computation of the thermoelastic stresses. The thermal model was correlated to a full scale plug repair radiant test. To utilize the thermal model for flight analyses, accurate predictions of protuberance heating were required. Wind tunnel testing was performed at CUBRC to characterize the heat flux in both the radial and angular directions. Due to the complexity of the implementation of the protuberance heating, an intermediate program was developed to output the heating per nodal location for all OML surfaces in SINDA format. Three Design Reference Cases (DRC) were evaluated with the correlated plug thermal math model to bound the environments which the plug repair would potentially be used.
A novel hydrogel plug of Sterculia urens for pulsatile delivery: in vitro and in vivo evaluation.
Amrutkar, Jitendra R; Gattani, Surendra G
2012-01-01
The objective of this study was to investigate a novel hydrogel plug using isolated root mucilage of Sterculia urens to obtain a desired lag time for an oral chronotherapeutic colon-specific pulsatile drug delivery of indomethacin. Pulsatile drug delivery was developed using chemically treated hard gelatin capsule bodies filled with eudragit multiparticulates of indomethacin, and sealed with different hydrogel plugs (root mucilage of S. urens, xanthan gum, guar gum, HPMC K4M and combination of maltodextrin with guar gum). Indomethacin multiparticulates were prepared using extrusion spheronization, spray drying and solvent evaporation techniques with Eudragit® L-100 and S-100 (1:2) by varying drug-to-polymer ratio. After oral administration, the water-soluble cap of capsule dissolved in the intestinal fluid and the hydrogel plug swells. After a controlled time, the swollen plug subsequently ejected from the dosage form, releases the contents of the capsule. The formulation factors affecting the drug release were concentration and types of hydrogel plug used. In vivo gamma scintigraphy study in healthy rabbits proved the capability of the system to release drug in lower parts of the gastrointestinal tract after a programmed lag time. This study demonstrates that the indomethacin multiparticulates could be successfully colon-targeted by the design of time and pH-dependent modified chronopharmaceutical formulation. In conclusion, the investigated novel hydrogel plug could be a valuable tool for achieving desired lag time.
Does aphid salivation affect phloem sieve element occlusion in vivo?
Medina-Ortega, Karla J; Walker, G P
2013-12-01
To protect against loss of photo-assimilate-rich phloem sap, plants have evolved several mechanisms to plug phloem sieve tubes in response to damage. In many Fabaceae, each sieve element contains a discrete proteinaceous body called a forisome, which, in response to damage, rapidly transforms from a condensed configuration that does not impede the flow of sap to a dispersed configuration that plugs the sieve element. Aphids and other specialized phloem sap feeders can ingest phloem sap from a single sieve element for hours or days, and to do this, they must be able to suppress or reverse phloem plugging. A recent study provided in vitro evidence that aphid saliva can reverse forisome plugs. The present study tested this hypothesis in vivo by inducing forisome plugs which triggered aphids to switch behaviour from phloem sap ingestion to salivation into the sieve element. After salivating into the sieve element for various periods of time, the aphids were instantaneously cryofixed (freeze fixed) in situ on their leaf. The state of the forisome was then determined in the penetrated sieve element and in nearby non-penetrated sieve elements which served as controls for sieve elements not subjected to direct aphid salivation. Forisomes were almost always in close contact with the stylet tips and thus came into direct contact with the saliva. Nonetheless, forisome plugs in the penetrated sieve element did not revert back to a non-plugging state any faster than those in neighbouring sieve elements that were not subjected to direct aphid salivation.
Reinhold, Ann Marie; Poole, Geoffrey C; Bramblett, Robert G; Zale, Alexander V; Roberts, David W
2018-04-24
Determining the influences of anthropogenic perturbations on side channel dynamics in large rivers is important from both assessment and monitoring perspectives because side channels provide critical habitat to numerous aquatic species. Side channel extents are decreasing in large rivers worldwide. Although riprap and other linear structures have been shown to reduce side channel extents in large rivers, we hypothesized that small "anthropogenic plugs" (flow obstructions such as dikes or berms) across side channels modify whole-river geomorphology via accelerating side channel senescence. To test this hypothesis, we conducted a geospatial assessment, comparing digitized side channel areas from aerial photographs taken during the 1950s and 2001 along 512 km of the Yellowstone River floodplain. We identified longitudinal patterns of side channel recruitment (created/enlarged side channels) and side channel attrition (destroyed/senesced side channels) across n = 17 river sections within which channels were actively migrating. We related areal measures of recruitment and attrition to the density of anthropogenic side channel plugs across river sections. Consistent with our hypothesis, a positive spatial relationship existed between the density of anthropogenic plugs and side channel attrition, but no relationship existed between plug density and side channel recruitment. Our work highlights important linkages among side channel plugs and the persistence and restoration of side channels across floodplain landscapes. Specifically, management of small plugs represents a low-cost, high-benefit restoration opportunity to facilitate scouring flows in side channels to enable the persistence of these habitats over time.
Does aphid salivation affect phloem sieve element occlusion in vivo?
Medina-Ortega, Karla J.
2013-01-01
To protect against loss of photo-assimilate-rich phloem sap, plants have evolved several mechanisms to plug phloem sieve tubes in response to damage. In many Fabaceae, each sieve element contains a discrete proteinaceous body called a forisome, which, in response to damage, rapidly transforms from a condensed configuration that does not impede the flow of sap to a dispersed configuration that plugs the sieve element. Aphids and other specialized phloem sap feeders can ingest phloem sap from a single sieve element for hours or days, and to do this, they must be able to suppress or reverse phloem plugging. A recent study provided in vitro evidence that aphid saliva can reverse forisome plugs. The present study tested this hypothesis in vivo by inducing forisome plugs which triggered aphids to switch behaviour from phloem sap ingestion to salivation into the sieve element. After salivating into the sieve element for various periods of time, the aphids were instantaneously cryofixed (freeze fixed) in situ on their leaf. The state of the forisome was then determined in the penetrated sieve element and in nearby non-penetrated sieve elements which served as controls for sieve elements not subjected to direct aphid salivation. Forisomes were almost always in close contact with the stylet tips and thus came into direct contact with the saliva. Nonetheless, forisome plugs in the penetrated sieve element did not revert back to a non-plugging state any faster than those in neighbouring sieve elements that were not subjected to direct aphid salivation. PMID:24127515
The embryologic development of the human external auditory meatus. Preliminary report.
Nishimura, Y; Kumoi, T
1992-01-01
During the final period of embryogenesis, a funnel-shaped tube continues medially into the mesenchymal tissue forming a curved path. Although this may sound simple, the development occurring during early fetal life is in fact very complex. At first, ectodermal cells proliferate to fill the lumen of the meatus, forming the meatal plug, and then at 10 weeks the bottom of the plug extends in a disc-like fashion, so that in the horizontal plane the meatus is boot-shaped with a narrow neck and the sole of the meatal plug spreading widely to form the future tympanic membrane medially. At the same time, the plug in the proximal portion of the neck starts to be resorbed. In the 13-week fetus, the disc-like plug begins to show signs of its final destiny; the innermost surface of the plug in contact with the anlage of the malleus is ready to contribute to the formation of the tympanic membrane. In the 15-week fetus, the innermost portion of the disc-like plug splits, leaving a thin ectodermal cell layer of immature tympanic membrane. The neck of the boot forms the border between the primary and secondary meatus, and is the last part to split. In the 16.5-week fetus, the meatus is fully patent throughout its entire length, although the lumen is still narrow and curved. In the 18-week fetus, the meatus is already fully expanded to its complete form.
Steel refining possibilities in LF
NASA Astrophysics Data System (ADS)
Dumitru, M. G.; Ioana, A.; Constantin, N.; Ciobanu, F.; Pollifroni, M.
2018-01-01
This article presents the main possibilities for steel refining in Ladle Furnace (LF). These, are presented: steelmaking stages, steel refining through argon bottom stirring, online control of the bottom stirring, bottom stirring diagram during LF treatment of a heat, porous plug influence over the argon stirring, bottom stirring porous plug, analysis of porous plugs disposal on ladle bottom surface, bottom stirring simulation with ANSYS, bottom stirring simulation with Autodesk CFD.
Rehabilitating gravel areas with short-hair sedge sod plugs and fertilizer
Raymond D. Ratliff
1985-01-01
Tests to rehabilitate gravel areas in high value recreation sites were carried out by transplanting short-hair sedge (Carex exserta) plugs. The plugs were 1.9 cm (0.75 inch) and 5.1 cm (2.0 inches) in diameter, 10 cm (4.0 inches) deep, and were transplanted in September 1981, with and without papier-mache pots. The test site was Siberian Outpost, in...
Percutaneous treatment of a duodenocutaneous high-flow fistula using a new biological plug
Vallejo, Eduardo Crespo; Martinez-Galdamez, Mario; Del Olmo Martínez, Lourdes; Brunet, Eduardo Crespo; Martin, Ernesto Santos
2015-01-01
Enterocutaneous fistula is a challenging entity and a gold-standard treatment is not settled so far. Here, we describe the successful closure of a duodenocutaneous fistula with the use of the Biodesign enterocutaneous fistula plug (Cook Medical), which is derived from a biological plug that has been used in recent years in order to close anorectal fistula tracts. PMID:25835076
NREL Research Determines Integration of Plug-in Electric Vehicles Should
transportation and energy systems engineer at NREL and author of the new Nature Energy paper, "Impact of Muratori, author of the new Nature Energy paper "Impact of Uncoordinated Plug-in Electric Vehicle Integration of Plug-in Electric Vehicles Should Play a Big Role in Future Electric System Planning News
Medical Device Plug-and-Play Interoperability Standards and Technology Leadership
2017-10-01
Award Number: W81XWH-09-1-0705 TITLE: “Medical Device Plug-and-Play Interoperability Standards and Technology Leadership” PRINCIPAL INVESTIGATOR...Sept 2016 – 20 Sept 2017 4. TITLE AND SUBTITLE “Medical Device Plug-and-Play Interoperability 5a. CONTRACT NUMBER Standards and Technology ...efficiency through interoperable medical technologies . We played a leadership role on interoperability safety standards (AAMI, AAMI/UL Joint
NaK Plugging Meter Design for the Feasibility Test Loops
NASA Technical Reports Server (NTRS)
Pearson, J. Boise; Godfroy, Thomas J.; Reid, Robert S.; Polzin, Kurt A.
2008-01-01
The design and predicted performance of a plugging meter for use in the measurement of NaK impurity levels are presented. The plugging meter is incorporated into a Feasibility Test Loop (FTL), which is a small pumped-NaK loop designed to enable the rapid, small-scale evaluation of techniques such as in situ purification methods and to permit the measurement of bulk material transport effects (not mechanisms) under flow conditions that are representative of a fission surface power reactor. The FTL operates at temperatures similar to those found in a reactor, with a maximum hot side temperature of 900 K and a corresponding cold side temperature of 860 K. In the plugging meter a low flow rate bypass loop is cooled until various impurities (primarily oxides) precipitate out of solution. The temperatures at which these impurities precipitate are indicative of the level of impurities in the NaK. The precipitates incrementally plug a small orifice in the bypass loop, which is detected by monitoring changes in the liquid metal flow rate.
Valley plugs, land use, and phytogeomorphic response: Chapter 14
Pierce, Aaron R.; King, Sammy L.; Shroder, John F.
2013-01-01
Anthropogenic alteration of fluvial systems can disrupt functional processes that provide valuable ecosystem services. Channelization alters fluvial parameters and the connectivity of river channels to their floodplains which is critical for productivity, nutrient cycling, flood control, and biodiversity. The effects of channelization can be exacerbated by local geology and land-use activities, resulting in dramatic geomorphic readjustments including the formation of valley plugs. Considerable variation in the response of abiotic processes, including surface hydrology, subsurface hydrology, and sedimentation dynamics, to channelization and the formation of valley plugs. Altered abiotic processes associated with these geomorphic features and readjustments influence biotic processes including species composition, abundance, and successional processes. Considerable interest exists for restoring altered fluvial systems and their floodplains because of their social and ecological importance. Understanding abiotic and biotic responses of channelization and valley-plug formation within the context of the watershed is essential to successful restoration. This chapter focuses on the primary causes of valley-plug formation, resulting fluvial-geomorphic responses, vegetation responses, and restoration and research needs for these systems.
Pericardium Plug in the Repair of the Corneoscleral Fistula After Ahmed Glaucoma Valve Explantation
Yoo, Chungkwon; Kwon, Sung Wook
2008-01-01
We report four cases in which a pericardium (Tutoplast®) plug was used to repair a corneoscleral fistula after Ahmed Glaucoma Valve (AGV) explantation. In four cases in which the AGV tube had been exposed, AGV explantation was performed using a pericardium (Tutoplast®) plug to seal the defect previously occupied by the tube. After debridement of the fistula, a piece of processed pericardium (Tutoplast®), measured 1 mm in width, was plugged into the fistula and secured with two interrupted 10-0 nylon sutures. To control intraocular pressure, a new AGV was implanted elsewhere in case 1, phaco-trabeculectomy was performed concurrently in case 2, cyclophotocoagulation was performed postoperatively in case 3 and anti-glaucomatous medication was added in case 4. No complication related to the fistula developed at the latest follow-up (range: 12~26 months). The pericardium (Tutoplast®) plug seems to be an effective method in the repair of corneoscleral fistulas resulting from explantation of glaucoma drainage implants. PMID:19096247
Biodegradable microfabricated plug-filters for glaucoma drainage devices.
Maleki, Teimour; Chitnis, Girish; Park, Jun Hyeong; Cantor, Louis B; Ziaie, Babak
2012-06-01
We report on the development of a batch fabricated biodegradable truncated-cone-shaped plug filter to overcome the postoperative hypotony in nonvalved glaucoma drainage devices. Plug filters are composed of biodegradable polymers that disappear once wound healing and bleb formation has progressed past the stage where hypotony from overfiltration may cause complications in the human eye. The biodegradable nature of device eliminates the risks associated with permanent valves that may become blocked or influence the aqueous fluid flow rate in the long term. The plug-filter geometry simplifies its integration with commercial shunts. Aqueous humor outflow regulation is achieved by controlling the diameter of a laser-drilled through-hole. The batch compatible fabrication involves a modified SU-8 molding to achieve truncated-cone-shaped pillars, polydimethylsiloxane micromolding, and hot embossing of biodegradable polymers. The developed plug filter is 500 μm long with base and apex plane diameters of 500 and 300 μm, respectively, and incorporates a laser-drilled through-hole with 44-μm effective diameter in the center.
Ackerson, J.R.; Schmitt, C.J.; McKee, M.J.; Brumbaugh, W.G.
2013-01-01
A non-lethal biopsy method for monitoring mercury (Hg) concentrations in smallmouth bass (Micropterus dolomieu; smallmouth) from the Eleven Point River in southern Missouri USA was evaluated. A biopsy punch was used to remove a muscle tissue plug from the area immediately below the anterior dorsal fin of 31 smallmouth. An additional 35 smallmouth (controls) were held identically except that no tissue plug was removed. After sampling, all fish were held in a concrete hatchery raceway for 6 weeks. Mean survival at the end of the holding period was 97 % for both groups. Smallmouth length, weight and Fulton’s condition factor at the end of the holding period were also similar between plugged and non-plugged controls, indicating that the biopsy procedure had minimal impact on growth under these conditions. Tissue plug Hg concentrations were similar to smallmouth Hg data obtained in previous years by removing the entire fillet for analysis.
Ackerson, R.J.; McKee, J.M.; Schmitt, C.J.; Brumbaugh, William G.
2014-01-01
A non-lethal biopsy method for monitoring mercury (Hg) concentrations in smallmouth bass (Micropterus dolomieu; smallmouth) from the Eleven Point River in southern Missouri USA was evaluated. A biopsy punch was used to remove a muscle tissue plug from the area immediately below the anterior dorsal fin of 31 smallmouth. An additional 35 smallmouth (controls) were held identically except that no tissue plug was removed. After sampling, all fish were held in a concrete hatchery raceway for 6 weeks. Mean survival at the end of the holding period was 97 % for both groups. Smallmouth length, weight and Fulton’s condition factor at the end of the holding period were also similar between plugged and non-plugged controls, indicating that the biopsy procedure had minimal impact on growth under these conditions. Tissue plug Hg concentrations were similar to smallmouth Hg data obtained in previous years by removing the entire fillet for analysis.
GIS Application System Design Applied to Information Monitoring
NASA Astrophysics Data System (ADS)
Qun, Zhou; Yujin, Yuan; Yuena, Kang
Natural environment information management system involves on-line instrument monitoring, data communications, database establishment, information management software development and so on. Its core lies in collecting effective and reliable environmental information, increasing utilization rate and sharing degree of environment information by advanced information technology, and maximizingly providing timely and scientific foundation for environmental monitoring and management. This thesis adopts C# plug-in application development and uses a set of complete embedded GIS component libraries and tools libraries provided by GIS Engine to finish the core of plug-in GIS application framework, namely, the design and implementation of framework host program and each functional plug-in, as well as the design and implementation of plug-in GIS application framework platform. This thesis adopts the advantages of development technique of dynamic plug-in loading configuration, quickly establishes GIS application by visualized component collaborative modeling and realizes GIS application integration. The developed platform is applicable to any application integration related to GIS application (ESRI platform) and can be as basis development platform of GIS application development.
Plug identification in drainage system using electromagnetic wave
NASA Astrophysics Data System (ADS)
Hijriani, Arifa; Utama, Aji Surya; Boas, Andrianus; Mukti, M. Ridho; Widodo
2017-07-01
The evaluation of drainage system's performance is an important thing to do to prevent flooding. Conventionally the Government evaluates the drainage system by opening one by one the lid of drainage and detects the plug manually. This method is not effective and efficient because this method need many people, much time and relatively expensive. The purpose of this paper is to identify plugs in drainage system in G St. at Bandung Institute of Technology by using electromagnetic wave. Ground Penetrating Radar (GPR) is one of geophysics method that using electromagnetic wave with high frequency. GPR is a non-destructive method with high resolution imaging for shallow depth (˜100m) and relatively cheap. We could identify the plug without opening the lid manually so that we could save much time. GPR's sensitivity is depends on resistivity, magnetic permeability, and permittivity of an object. The result of this research is we could identify the plug on the radargram that observed by a build-up amplitude anomaly.
Analysis of supersonic plug nozzle flowfield and heat transfer
NASA Technical Reports Server (NTRS)
Murthy, S. N. B.; Sheu, W. H.
1988-01-01
A number of problems pertaining to the flowfield in a plug nozzle, designed as a supersonic thruster nozzle, with provision for cooling the plug with a coolant stream admitted parallel to the plug wall surface, were studied. First, an analysis was performed of the inviscid, nonturbulent, gas dynamic interaction between the primary hot stream and the secondary coolant stream. A numerical prediction code for establishing the resulting flowfield with a dividing surface between the two streams, for various combinations of stagnation and static properties of the two streams, was utilized for illustrating the nature of interactions. Secondly, skin friction coefficient, heat transfer coefficient and heat flux to the plug wall were analyzed under smooth flow conditions (without shocks or separation) for various coolant flow conditions. A numerical code was suitably modified and utilized for the determination of heat transfer parameters in a number of cases for which data are available. Thirdly, an analysis was initiated for modeling turbulence processes in transonic shock-boundary layer interaction without the appearance of flow separation.
NASA Technical Reports Server (NTRS)
White, III, Dorsey E. (Inventor); Updike, deceased, Benjamin T. (Inventor); Allred, Johnny W. (Inventor)
1989-01-01
A quick actuating closure for a pressure vessel 80 in which a wedge ring 30 with a conical outer surface 31 is moved forward to force shear blocks 40, with conical inner surfaces 41, radially outward to lock an end closure plug 70 within an opening 81 in the pressure vessel 80. A seal ring 60 and a preload ramp 50 sit between the shear blocks 40 and the end closure plug 70 to provide a backup sealing capability. Conical surfaces 44 and 55 of the preload ramp 50 and the shear blocks 40 interact to force the seal ring 60 into shoulders 73 and 85 in the end closure plug 70 and opening 81 to form a tight seal. The end closure plug 70 is unlocked by moving the wedge ring 30 rearward, which causes T-bars 32 of the wedge ring 30 riding within T -slots 42 of the shear blocks 40 to force them radially inward. The end closure plug 70 is then removed, allowing access to the interior of the pressure vessel 80.
Transient motion of mucus plugs in respiratory airways
NASA Astrophysics Data System (ADS)
Zamankhan, Parsa; Hu, Yingying; Helenbrook, Brian; Takayama, Shuichi; Grotberg, James B.
2011-11-01
Airway closure occurs in lung diseases such as asthma, cystic fibrosis, or emphysema which have an excess of mucus that forms plugs. The reopening process involves displacement of mucus plugs in the airways by the airflow of respiration. Mucus is a non-Newtonian fluid with a yield stress; therefore its behavior can be approximated by a Bingham fluid constitutive equation. In this work the reopening process is approximated by simulation of a transient Bingham fluid plug in a 2D channel. The governing equations are solved by an Arbitrary Lagrangian Eulerian (ALE) finite element method through an in-house code. The constitutive equation for the Bingham fluid is implemented through a regularization method. The effects of the yield stress on the flow features and wall stresses are discussed with applications to potential injuries to the airway epithelial cells which form the wall. The minimum driving pressure for the initiation of the motion is computed and its value is related to the mucus properties and the plug shape. Supported by HL84370 and HL85156.
Best Practices for Fuel System Contamination Detection and Remediation
2015-12-14
Valve Fyre Ring GR DBB Style Plug Valve Gasket SS graphite Spiral DBB Style Plug Valve O- rings & slip seals VI DBB Style Plug Valve Packing gland...Pumps Impeller Key SS Vertical Turbine Pumps Impeller Retaining Ring SS Vertical Turbine Pumps Impellers (Electroless Nickel Plating) DI Vertical... Turbine Pumps Line Shaft SS Vertical Turbine Pumps Lineshaft Bearing CA Vertical Turbine Pumps Mating Ring Si-C Vertical Turbine Pumps Mechanical
Best Practices for Fuel System Contamination Detection and Remediation
2016-01-15
Valve Fyre Ring GR DBB Style Plug Valve Gasket SS graphite Spiral DBB Style Plug Valve O- rings & slip seals VI DBB Style Plug Valve Packing gland...Pumps Impeller Key SS Vertical Turbine Pumps Impeller Retaining Ring SS Vertical Turbine Pumps Impellers (Electroless Nickel Plating) DI Vertical... Turbine Pumps Line Shaft SS Vertical Turbine Pumps Lineshaft Bearing CA Vertical Turbine Pumps Mating Ring Si-C Vertical Turbine Pumps Mechanical
APPARATUS FOR LOADING AND UNLOADING A MACHINE
Payne, J.H. Jr.
1962-07-17
An arrangement for loading and unloading a nuclear reactor is described. Depleted fuel elements are removed from the reactor through one of a small number of holes in a shielding plug that is rotatably mounted in an eccentric annular plug rotatably mounted in the top of the reactor. The fuel elements removed are stored in a plurality of openings in a rotatable magazine or storage means rotatably mounted over the plugs. (AEC)
Peng, Yi-Jie; Kau, Yi-Chuan; Wen, Chin-Wei; Liu, Kuo-Sheng; Liu, Shih-Jung
2010-08-01
Delivering effective drugs at sufficiently high concentrations to the area of infection is a standard treatment for infectious disease, such as endophthalmitis. This is currently done by empirical trans pars plana intravitreal injection of both antibiotics directed against gram-positive and gram-negative microorganisms and steroids. However, injections by needles repeatedly may increase the risks of intraocular infection and hemorrhage, as well as retinal detachment. This article explores the alternative of using biodegradable polymers as scleral plugs for a long-term drug release in vivo. To manufacture plugs, poly(lactide-glycolide) copolymers were first mixed with vancomycin, amikacin, and dexamethasone. The mixture was compressed and sintered at 55 degrees C to form scleral plugs 1.4 mm in diameter. Biodegradable scleral plugs released high concentrations of antibiotics (well above the minimum inhibitory concentrations, MIC) and steroids in vivo for the period of time needed to treat intraocular infection. In addition, no major complications such as infectious or sterile endophthalmitis, retinal detachment, ocular phthisis, or uvea protrusion at sclerotomy site were observed throughout the experiment. The sclerotomy wound healed after total degradation of the scleral implants without leakage or local necrosis. Antibiotic/steroid-impregnated biodegradable scleral plugs may have a potential role in the treatment of various intraocular infections. (c) 2010 Wiley Periodicals, Inc.
In Vitro Microfluidic Models of Mucus-Like Obstructions in Small Airways
NASA Astrophysics Data System (ADS)
Mulligan, Molly K.; Grotberg, James B.; Sznitman, Josué
2012-11-01
Liquid plugs can form in the lungs as a result of a host of different diseases, including cystic fibrosis and chronic obstructive pulmonary disease. The existence of such fluid obstructions have been found as far down in the bronchiole tree as the sixteenth generation, where bronchiole openings have diameters on the order of a hundred to a few hundred microns. Understanding the propagation of liquid plugs within the bifurcating branches of bronchiole airways is important because their presence in the lungs, and their rupture and break-up, can cause injury to the epithelial cells lining the airway walls as a result of high wall shear stresses. In particular, liquid plug rupture and break-up frequently occurs at airway bifurcations. Until present, however, experimental studies of liquid plugs have generally been restricted to Newtonian fluids that do not reflect the actual pseudoplastic properties of lung mucus. The present work attempts to uncover the propagation, rupture and break-up of mucus-like liquid plugs in the lower generations of the airway tree using microfluidic models. Our approach allows the dynamics of mucus-like plug break-up to be studied in real-time, in a one-to-one in vitro model, as a function of mucus rheology and bronchial tree geometry.
Saito, Kazuki; Nakato, Mamiko; Mizuguchi, Takaaki; Wada, Shinji; Uchimura, Hiromasa; Kataoka, Hiroshi; Yokoyama, Shigeyuki; Hirota, Hiroshi; Kiso, Yoshiaki
2014-03-01
To discover peptide ligands that bind to a target protein with a higher molecular mass, a concise screening methodology has been established, by applying a "plug-plug" technique to ACE experiments. Exploratory experiments using three mixed peptides, mastoparan-X, β-endorphin, and oxytocin, as candidates for calmodulin-binding ligands, revealed that the technique not only reduces the consumption of the protein sample, but also increases the flexibility of the experimental conditions, by allowing the use of MS detection in the ACE experiments. With the plug-plug technique, the ACE-MS screening methodology successfully selected calmodulin-binding peptides from a random library with diverse constituents, such as protease digests of BSA. Three peptides with Kd values between 8-147 μM for calmodulin were obtained from a Glu-C endoprotease digest of reduced BSA, although the digest showed more than 70 peaks in its ACE-MS electropherogram. The method established here will be quite useful for the screening of peptide ligands, which have only low affinities due to their flexible chain structures but could potentially provide primary information for designing inhibitors against the target protein. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Forisome performance in artificial sieve tubes.
Knoblauch, Michael; Stubenrauch, Mike; van Bel, Aart J E; Peters, Winfried S
2012-08-01
In the legume phloem, sieve element occlusion (SEO) proteins assemble into Ca(2+)-dependent contractile bodies. These forisomes presumably control phloem transport by forming reversible sieve tube plugs. This function, however, has never been directly demonstrated, and appears questionable as forisomes were reported to be too small to plug sieve tubes, and failed to block flow efficiently in artificial microchannels. Moreover, plugs of SEO-related proteins in Arabidopsis sieve tubes do not affect phloem translocation. We improved existing procedures for forisome isolation and storage, and found that the degree of Ca(2+)-driven deformation that is possible in forisomes of Vicia faba, the standard object of earlier research, has been underestimated substantially. Forisomes deform particularly strongly under reducing conditions and high sugar concentrations, as typically found in sieve tubes. In contrast to our previous inference, Ca(2+)-inducible forisome swelling certainly seems sufficient to plug sieve tubes. This conclusion was supported by 3D-reconstructions of forisome plugs in Canavalia gladiata. For a direct test, we built microfluidics chips with artificial sieve tubes. Using fluorescent dyes to visualize flow, we demonstrated the complete blockage of these biomimetic microtubes by Ca(2+)-induced forisome plugs, and concluded by analogy that forisomes are capable of regulating phloem flow in vivo. © 2012 Blackwell Publishing Ltd.
Engels, A C; Hoylaerts, M F; Endo, M; Loyen, S; Verbist, G; Manodoro, S; DeKoninck, P; Richter, J; Deprest, J A
2013-02-01
We aimed to demonstrate local thrombin generation by fetal membranes, as well as its ability to generate fibrin from fibrinogen concentrate. Furthermore, we aimed to investigate the efficacy of collagen plugs, soaked with plasma and fibrinogen, to seal iatrogenic fetal membrane defects. Thrombin generation by homogenized fetal membranes was measured by calibrated automated thrombography. To identify the coagulation caused by an iatrogenic membrane defect, we analyzed fibrin formation by optical densitometry, upon various concentrations of fibrinogen. The ability of a collagen plug soaked with fibrinogen and plasma was tested in an ex vivo model for its ability to seal an iatrogenic fetal membrane defect. Fetal membrane homogenates potently induced thrombin generation in amniotic fluid and diluted plasma. Upon the addition of fibrinogen concentrate, potent fibrin formation was triggered. Measured by densiometry, fibrin formation was optimal at 1250 µg/mL fibrinogen in combination with 4% plasma. A collagen plug soaked with fibrinogen and plasma sealed an iatrogenic membrane defect about 35% better than collagen plugs without these additives (P = 0.037). These in vitro experiments suggest that the addition of fibrinogen and plasma may enhance the sealing efficacy of collagen plugs in closing iatrogenic fetal membrane defects. © 2013 John Wiley & Sons, Ltd.
The subsidiary gap as a means for improving ignition
NASA Technical Reports Server (NTRS)
Gorton, W S
1920-01-01
This report was prepared at the Bureau of Standards for the National Advisory Committee for Aeronautics. Additional or subsidiary gaps have frequently been used in jump-spark ignition systems, in order to cause the resumption of sparking in fouled spark plugs. The series gap, to which the greater part of this report is devoted, is a subsidiary gap in the connection between the high tension terminal of the plug and that of the magneto or coil. A brief account is given of the use of this gap up to the present time and also of the statements concerning it which have gained some currency, most of which are shown to be erroneous. The simple theory of the action of the series gap is discussed and a detailed account given of the effect upon the sparking ability of the plug produced by changes in the values of the electrical resistance of the fouling and of the capacities in parallel with the plug and with the magneto or coil. This report presents the results of an investigation into the utility, action, and design of the auxiliary spark gap as a means for insuring freedom from spark plug failure due to fouling, and also to enable the restarting of fouled plugs.
Zara, Fernando Jose; Raggi Pereira, Gerson Rodrigues; Sant'anna, Bruno Sampaio
2014-08-01
To understand sperm plug dissolution and spermatophore dehiscence in Portunidae, histological and ultrastructural changes in the seminal receptacle (SR) of Arenaeus cribrarius were investigated during ovarian development. In juvenile females the SR was filled with acid polysaccharides and the dorsal epithelium was stratified. Mated females with rudimentary ovaries showed a large SR filled by a glycoprotein sperm plug. This plug was present until the developing-ovary stage, when spermatophore dehiscence and intense holocrine secretions in the dorsal dense layer occurred. The plug was absent after the intermediate stage, and the SR became flaccid. The secretion produced moved the spermatophores into the ventral region. The modified dorsal epithelium in the transition between the dorsal and ventral regions released acid polysaccharides, which were found among the sperm, by exocytosis. The morphological changes of the SR in A. cribrarius, including the presence of the sperm plug, followed the macroscopic pattern observed in other members of Portunidae, such as blue crabs. However, in this species dissolution of the sperm plug was synchronized with ovarian development and occurred simultaneously with spermatophore dehiscence, showing the evolutionary relationship of the seminal receptacle and the female reproductive system to the storage of spermatophores and spermatozoa. © 2014 Marine Biological Laboratory.
Molecular basis of the copulatory plug polymorphism in C. elegans
Palopoli, Michael F.; Rockman, Matthew V.; TinMaung, Aye; Ramsay, Camden; Curwen, Stephen; Aduna, Andrea; Laurita, Jason; Kruglyak, Leonid
2008-01-01
Heritable variation is the raw material for evolutionary change, and understanding its genetic basis is one of the central problems in modern biology. We investigated the genetic basis of a classic phenotypic dimorphism in the nematode Caenorhabditis elegans. Males from many natural isolates deposit a copulatory plug after mating, whereas males from other natural isolates—including the standard wild-type strain (N2 Bristol) that is used in most research laboratories—do not deposit plugs1. The copulatory plug is a gelatinous mass that covers the hermaphrodite vulva, and its deposition decreases the mating success of subsequent males2. We show that the plugging polymorphism results from the insertion of a retrotransposon into an exon of a novel mucin-like gene, plg-1, whose product is a major structural component of the copulatory plug. The gene is expressed in a subset of secretory cells of the male somatic gonad, and its loss has no evident effects beyond the loss of male mate-guarding. Although C. elegans descends from an obligate-outcrossing, male-female ancestor3, 4, it occurs primarily as self-fertilizing hermaphrodites5–7. The reduced selection on male-male competition associated with the origin of hermaphroditism may have permitted the global spread of a loss-of-function mutation with restricted pleiotropy. PMID:18633349
Damage Tolerance Assessment of Friction Pull Plug Welds
NASA Technical Reports Server (NTRS)
McGill, Preston; Burkholder, Jonathan
2012-01-01
Friction stir welding is a solid state welding process developed and patented by The Welding Institute in Cambridge, England. Friction stir welding has been implemented in the aerospace industry in the fabrication of longitudinal welds in pressurized cryogenic propellant tanks. As the industry looks to implement friction stir welding in circumferential welds in pressurized cryogenic propellant tanks, techniques to close out the termination hole associated with retracting the pin tool are being evaluated. Friction pull plug welding is under development as a one means of closing out the termination hole. A friction pull plug weld placed in a friction stir weld results in a non-homogenous weld joint where the initial weld, plug weld, their respective heat affected zones and the base metal all interact. The welded joint is a composite, plastically deformed material system with a complex residual stress field. In order to address damage tolerance concerns associated with friction plug welds in safety critical structures, such as propellant tanks, nondestructive inspection and proof testing may be required to screen hardware for mission critical defects. The efficacy of the nondestructive evaluation or the proof test is based on an assessment of the critical flaw size in the test or service environments. Test data relating residual strength capability to flaw size in two aluminum alloy friction plug weld configurations is presented.
In-use measurement of activity, energy use, and emissions of a plug-in hybrid electric vehicle.
Graver, Brandon M; Frey, H Christopher; Choi, Hyung-Wook
2011-10-15
Plug-in hybrid electric vehicles (PHEVs) could reduce transportation air emissions and energy use. However, a method is needed for estimating on-road emissions of PHEVs. To develop a framework for quantifying microscale energy use and emissions (EU&E), measurements were conducted on a Toyota Prius retrofitted with a plug-in battery system on eight routes. Measurements were made using the following: (1) a data logger for the hybrid control system; (2) a portable emissions measurement system; and (3) a global positioning system with barometric altimeter. Trends in EU&E are estimated based on vehicle specific power. Energy economy is quantified based on gasoline consumed by the engine and grid energy consumed by the plug-in battery. Emissions from electricity consumption are estimated based on the power generation mix. Fuel use is approximately 30% lower during plug-in battery use. Grid emissions were higher for CO₂, NO(x), SO₂, and PM compared to tailpipe emissions but lower for CO and hydrocarbons. EU&E depends on engine and plug-in battery operation. The use of two energy sources must be addressed in characterizing fuel economy; overall energy economy is 11% lower if including grid energy use than accounting only for fuel consumption.
Versatile Friction Stir Welding/Friction Plug Welding System
NASA Technical Reports Server (NTRS)
Carter, Robert
2006-01-01
A proposed system of tooling, machinery, and control equipment would be capable of performing any of several friction stir welding (FSW) and friction plug welding (FPW) operations. These operations would include the following: Basic FSW; FSW with automated manipulation of the length of the pin tool in real time [the so-called auto-adjustable pin-tool (APT) capability]; Self-reacting FSW (SRFSW); SR-FSW with APT capability and/or real-time adjustment of the distance between the front and back shoulders; and Friction plug welding (FPW) [more specifically, friction push plug welding] or friction pull plug welding (FPPW) to close out the keyhole of, or to repair, an FSW or SR-FSW weld. Prior FSW and FPW systems have been capable of performing one or two of these operations, but none has thus far been capable of performing all of them. The proposed system would include a common tool that would have APT capability for both basic FSW and SR-FSW. Such a tool was described in Tool for Two Types of Friction Stir Welding (MFS- 31647-1), NASA Tech Briefs, Vol. 30, No. 10 (October 2006), page 70. Going beyond what was reported in the cited previous article, the common tool could be used in conjunction with a plug welding head to perform FPW or FPPW. Alternatively, the plug welding head could be integrated, along with the common tool, into a FSW head that would be capable of all of the aforementioned FSW and FPW operations. Any FSW or FPW operation could be performed under any combination of position and/or force control.
2014/2219 Tri-Point Crack Analysis
NASA Technical Reports Server (NTRS)
Horton, Karla Renee
2011-01-01
Friction stir welding (FSW) is a solid state welding process with potential advantages for aerospace and automotive industries dealing with light alloys. Self-reacting friction stir welding (SR-FSW) is one variation of the FSW process being developed at the National Aeronautics and Space Administration (NASA) for use in the fabrication of propellant tanks. Friction plug welding is used to seal the exit hole that remains in a circumferential SR-FSW. The objective of this study was to evaluate the deformation response at the tips of cracks located in the heat affected zone of friction plug welds and to study the fracture behavior of welds with defects in the form of fatigue cracks. The study used existing 2014-T6 to 2219-T87 self-reacting friction stir weld panels with 2219-T87 friction plug welds. Electro-discharge machined (EDM) notches were machined into the heat affected zone of the plug at the plug-to-base metal interface. Samples were then cycled to generate a fatigue crack emanating from the notch. After the fatigue crack reached a pre-defined length, a speckle pattern was applied and the ARAMIS system (a three dimensional imaging correlation system) was used to measure the deformations at the crack tip under a sequence of loads. Testing was conducted at ambient laboratory conditions. Fracture data from the testing was analyzed to evaluate residual strength capability of the panel as a function of flaw size. ARAMIS strain data was evaluated to examine strain and deformation patterns that develop around the crack tip and at the plug/weld interfaces. Four samples were used in this study, with three samples in a post-weld heat treated condition. Three samples contained large diameter plugs (M5) and one sample contained a small diameter plug (M3). Two samples were 4 inches in width and two samples were 8.5 inches in width. All samples failed through the precrack with residual strengths ranging from 37 ksi to 42 ksi.
System for Packaging Planetary Samples for Return to Earth
NASA Technical Reports Server (NTRS)
Badescu, Mircea; Bar-Cohen, Yoseph; Backes, paul G.; Sherrit, Stewart; Bao, Xiaoqi; Scott, James S.
2010-01-01
A system is proposed for packaging material samples on a remote planet (especially Mars) in sealed sample tubes in preparation for later return to Earth. The sample tubes (Figure 1) would comprise (1) tubes initially having open tops and closed bottoms; (2) small, bellows-like collapsible bodies inside the tubes at their bottoms; and (3) plugs to be eventually used to close the tops of the tubes. The top inner surface of each tube would be coated with solder. The side of each plug, which would fit snugly into a tube, would feature a solder-filled ring groove. The system would include equipment for storing, manipulating, filling, and sealing the tubes. The containerization system (see Figure 2) will be organized in stations and will include: the storage station, the loading station, and the heating station. These stations can be structured in circular or linear pattern to minimize the manipulator complexity, allowing for compact design and mass efficiency. The manipulation of the sample tube between stations is done by a simple manipulator arm. The storage station contains the unloaded sample tubes and the plugs before sealing as well as the sealed sample tubes with samples after loading and sealing. The chambers at the storage station also allow for plug insertion into the sample tube. At the loading station the sample is poured or inserted into the sample tube and then the tube is topped off. At the heating station the plug is heated so the solder ring melts and seals the plug to the sample tube. The process is performed as follows: Each tube is filled or slightly overfilled with sample material and the excess sample material is wiped off the top. Then, the plug is inserted into the top section of the tube packing the sample material against the collapsible bellowslike body allowing the accommodation of the sample volume. The plug and the top of the tube are heated momentarily to melt the solder in order to seal the tube.
Ceramic Borehole Seals for Nuclear Waste Disposal Applications
NASA Astrophysics Data System (ADS)
Lowry, B.; Coates, K.; Wohletz, K.; Dunn, S.; Patera, E.; Duguid, A.; Arnold, B.; Zyvoloski, G.; Groven, L.; Kuramyssova, K.
2015-12-01
Sealing plugs are critical features of the deep borehole system design. They serve as structural platforms to bear the weight of the backfill column, and as seals through their low fluid permeability and bond to the borehole or casing wall. High hydrostatic and lithostatic pressures, high mineral content water, and elevated temperature due to the waste packages and geothermal gradient challenge the long term performance of seal materials. Deep borehole nuclear waste disposal faces the added requirement of assuring performance for thousands of years in large boreholes, requiring very long term chemical and physical stability. A high performance plug system is being developed which capitalizes on the energy of solid phase reactions to form a ceramic plug in-situ. Thermites are a family of self-oxidized metal/oxide reactions with very high energy content and the ability to react under water. When combined with engineered additives the product exhibits attractive structural, sealing, and corrosion properties. In the initial phase of this research, exploratory and scaled tests demonstrated formulations that achieved controlled, fine grained, homogeneous, net shape plugs composed predominantly of ceramic material. Laboratory experiments produced plug cores with confined fluid permeability as low as 100 mDarcy, compressive strength as high as 70 MPa (three times the strength of conventional well cement), with the inherent corrosion resistance and service temperature of ceramic matrices. Numerical thermal and thermal/structural analyses predicted the in-situ thermal performance of the reacted plugs, showing that they cooled to ambient temperature (and design strength) within 24 to 48 hours. The current development effort is refining the reactant formulations to achieve desired performance characteristics, developing the system design and emplacement processes to be compatible with conventional well service practices, and understanding the thermal, fluid, and structural effects the plug will have on surrounding media. This paper will report on the state of the development effort and plans for a field demonstration in early 2016 in a cased well with traditional plug seal and strength measurements.
Rapid fibrin plug formation within cutaneous ablative fractional CO2 laser lesions.
Kositratna, Garuna; Evers, Michael; Sajjadi, Amir; Manstein, Dieter
2016-02-01
Ablative fractional laser procedures have been shown to facilitate topical drug delivery into the skin. Past studies have mainly used ex vivo models to demonstrate enhanced drug delivery and in vivo studies have investigated laser created channels over a time course of days and weeks rather than within the first few minutes and hours after exposures. We have noticed rapid in vivo fibrin plug formation within ablative fractional laser lesions impairing passage through the laser created channels. In vivo laser exposures were performed in a porcine model. A fractional CO2 laser (AcuPulse™ system, AcuScan 120™ handpiece, Lumenis, Inc., Yokneam, Israel) was programmed in quasi-continuous wave (QCW) mode, at 40W, 50 mJ per pulse, 5% coverage, nominal 120 µm spot size, 8 × 8 mm square pattern, 169 MTZs per scan. Six millimeters punch biopsies were procured at 0, 2, 5, 10, 15, 30, 60, 90 minutes after completion of each scan, then fixed in 10% formalin. 12 repeats were performed of each time point. Skin samples were processed for serial vertically cut paraffin sections (5 μm collected every 25 μm) then H&E and special immunohistochemistry staining for fibrin and platelet. Dimensions of Microscopic Treatment Zones (MTZs) and extent of fibrin plug were assessed and quantified histologically. Ex vivo laser exposures of the identical laser parameter were performed on porcine and human skin at different storage conditions. Histology procured at various predetermined time intervals after in vivo fractional CO2 laser exposures revealed a rapidly forming fibrin plug initiating at the bottom of the MTZ lesions. At longer time intervals, the fibrin plug was extending towards the superficial sections. Within the first 5 minutes, more than 25% length of the entire laser-ablated channel was filled with a fibrin plug. With increased time intervals, the cavity was progressively filled with a fibrin plug. At 90 minutes, more than 90% length of the entire laser-ablated channel was occluded. Ex vivo exposures failed to produce any significant fibrin plug formation. The current study has demonstrated rapid fibrin plug formation after ablative fractional laser procedures. It was shown that the passage through laser created pathways is critically time dependent for in vivo exposures. In contrast, ex vivo exposures do not exhibit such time dependent passage capacity. In particular, drug, substance, and cell delivery studies for ablative fractional laser treatments should take early fibrin plug formation into consideration and further investigate the impact on transdermal delivery. © 2015 Wiley Periodicals, Inc.
NASA Technical Reports Server (NTRS)
Janardan, B. A.; Hoff, G. E.; Barter, J. W.; Brausch, J. F.; Gliebe, P. R.; Coffin, R. S.; Martens, S.; Delaney, B. R.; Dalton, W. N.; Mengle, V. G.
2000-01-01
This presentation discusses: Project Objectives, Approach and Goal; Baseline Nozzles and Test Cycle Definition; Repeatability and Baseline Nozzle Results; Noise Reduction Concepts; Noise Reduction Tests Configurations of BPR=5 Internal Plug Nozzle adn Acoustic Results; Noise Reduction Test Configurations of BPR=5 External Plug Nozzle and Acoustic Results; and Noise Reduction Tests Configurations of BPR=8 External Plug Nozzle and Acoustic Results.
MTR MAIN FLOOR. MEN DEMONSTRATE INSERTION OF DUMMY PLUG INTO ...
MTR MAIN FLOOR. MEN DEMONSTRATE INSERTION OF DUMMY PLUG INTO AN MTR BEAM HOLE. ONE MAN CHECKS RADIATION LEVEL AT THE END OF THE UNIVERSAL COFFIN, WHILE ANOTHER USES TOOL TO INSERT PLUG INTO HOLE THROUGH COFFIN. MEN WEAR "ANTI-C" (ANTI-CONTAMINATION) CLOTHING. INL NEGATIVE NO. 6198. R.G. Larsen, Photographer, 6/27/1952 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
DOE Office of Scientific and Technical Information (OSTI.GOV)
None
This is a Spanish-language brochure about hybrid and plug-in electric vehicles, which use electricity as their primary fuel or to improve the efficiency of conventional vehicle designs. These vehicles can be divided into three categories: hybrid electric vehicles (HEVs), plug-in hybrid electric vehicles (PHEVs), all-electric vehicles (EVs). Together, they have great potential to cut U.S. petroleum use and vehicle emissions.
City of Las Vegas Plug-in Hybrid Electric Vehicle Demonstration Program
DOE Office of Scientific and Technical Information (OSTI.GOV)
None
2013-12-31
The City of Las Vegas was awarded Department of Energy (DOE) project funding in 2009, for the City of Las Vegas Plug-in Hybrid Electric Vehicle Demonstration Program. This project allowed the City of Las Vegas to purchase electric and plug-in hybrid electric vehicles and associated electric vehicle charging infrastructure. The City anticipated the electric vehicles having lower overall operating costs and emissions similar to traditional and hybrid vehicles.
Doody, Thomas J.
1978-08-22
A multiple-port valve assembly is designed to direct flow from a primary conduit into any one of a plurality of secondary conduits as well as to direct a reverse flow. The valve includes two mating hemispherical sockets that rotatably receive a spherical valve plug. The valve plug is attached to the primary conduit and includes diverging passageways from that conduit to a plurality of ports. Each of the ports is alignable wih one or more of a plurality of secondary conduits fitted into one of the hemispherical sockets. The other hemispherical socket includes a slot for the primary conduit such that the conduit's motion along that slot with rotation of the spherical plug about various axes will position the valve-plug ports in respect to the secondary conduits.
Plug nozzles: The ultimate customer driven propulsion system
NASA Technical Reports Server (NTRS)
Aukerman, Carl A.
1991-01-01
This paper presents the results of a study applying the plug cluster nozzle concept to the propulsion system for a typical lunar excursion vehicle. Primary attention for the design criteria is given to user defined factors such as reliability, low volume, and ease of propulsion system development. Total thrust and specific impulse are held constant in the study while other parameters are explored to minimize the design chamber pressure. A brief history of the plug nozzle concept is included to point out the advanced level of technology of the concept and the feasibility of exploiting the variables considered in this study. The plug cluster concept looks very promising as a candidate for consideration for the ultimate customer driven propulsion system.
Effects of external stream flow and afterbody variations on the performance of a plug nozzle
NASA Technical Reports Server (NTRS)
Salmi, R J; Cortright, E M , Jr
1956-01-01
The off-design operation of an isentropic plug nozzle designed for a jet pressure ratio of 15 was investigated experimentally at subsonic Mach numbers up to 0.9 and jet pressure ratios up to 5. When installed in a cylindrical nacelle with a sharp turn at the nozzle lip, the interaction of the jet and the external stream produced low pressures on the base formed by the high lip angle. These low pressures increased the nacelle drag and caused an overexpansion of the jet, which resulted in lower pressures on the plug and, hence, reduced thrust. With a boattail ahead of the plug nozzle, the base pressures were increased and the jet overexpansion significantly reduced.
NASA Technical Reports Server (NTRS)
Aukerman, Carl A.
1991-01-01
This paper presents the results of a study applying the plug cluster nozzle concept to the propulsion system for a typical lunar excursion vehicle. Primary attention for the design criteria is given to user defined factors such as reliability, low volume, and ease of propulsion system development. Total thrust and specific impulse are held constant in the study while other parameters are explored to minimize the design chamber pressure. A brief history of the plug nozzle concept is included to point out the advanced level of technology of the concept and the feasibility of exploiting the variables considered in the study. The plug cluster concept looks very promising as a candidate for consideration for the ultimate customer driven propulsion system.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
This fact sheet highlights the Toyota Prius plug-in HEV, a plug-in hybrid electric car in the advanced technology vehicle fleet at the National Renewable Energy Laboratory (NREL). In partnership with the University of Colorado, NREL uses the vehicle for grid-integration studies and for testing new hardware and charge-management algorithms. NREL's advanced technology vehicle fleet features promising technologies to increase efficiency and reduce emissions without sacrificing safety or comfort. The fleet serves as a technology showcase, helping visitors learn about innovative vehicles that are available today or are in development. Vehicles in the fleet are representative of current, advanced, prototype, andmore » emerging technologies.« less
APPARATUS FOR MELTING AND POURING METAL
Harris, F.A.
1958-02-25
This patent relates to a crucible for melting and pouring a metal under controlled atmospheric conditions. The crucible has a frangible plug in the bottom and a retaining device to prevent the entrance of the broken portions of the plug into the mold without interfering with the flow of the melt. After the charge has been melted, a knockout rod is lowered through the charge and forced against the frangible plug sufficiently to break off the closure disk along a previously scored line. The disk drops onto a retaining grid large enough to permit the flow of metal around the disk and into the mold below. Thts arrangement elimnates the entry of broken portions of the plug into the mold, thereby elimnating a common cause of imperfect castings.
Effects of gravity, inertia, and surfactant on steady plug propagation in a two-dimensional channel
NASA Astrophysics Data System (ADS)
Zheng, Y.; Fujioka, H.; Grotberg, J. B.
2007-08-01
Liquid plugs may form in pulmonary airways during the process of liquid instillation or removal in many clinical treatments. Studies have shown that the effectiveness of these treatments may depend on how liquids distribute in the lung. Better understanding of the fundamental fluid mechanics of liquid plug transport will facilitate treatment strategies. In this paper, we develop a numerical model of steady plug propagation driven by gravity and pressure in a two-dimensional liquid-lined channel oriented at an angle α with respect to gravity. We investigate the effects of gravity through the Bond number, Bo, and α; the plug propagation speed through the capillary number, Ca, or the Reynolds number, Re; the plug length LP, and the surfactant concentration C0. Without gravity, i.e., Bo =0, the plug is symmetric, and there are two regimes for the flow: two wall layers and two trapped vortices in the core. There is no flow interaction between the upper and lower half plug domains. When Bo ≠0 and α ≠0, π, fluid is found to flow from the upper precursor film, through the core and into the lower trailing film. Then the number of vortices can be zero, one, or two, depending on the flow parameters. The vortices have stagnation points on the interface when C0=0, however when the surfactant is present (C0>0), the vortices detach from the interface and create saddle points inside the core. The front meniscus develops a capillary surface wave extending into the precursor film. This is where the film is thinnest and thus the wall shear stress is highest, as high as ˜100dyn /cm2 in adult airways, which indicates a significant risk of pulmonary airway epithelial cell damage. Adding surfactant can decrease the peak magnitude of the shear stress, thus reducing the risk of cell damage. The prebifurcation asymmetry of the plug is quantified by the volume ratio, Vr, defined as the ratio of the liquid above to that below the center line of the channel. Vr is found to increase with LP, Ca, Re, and C0, while it decreases with Bo. The total mass left behind in the trailing films increases with Bo for any α at α >2π/5, Ca and α for any value of Bo >0.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Saad, Wael E. A., E-mail: ws6r@virginia.edu; Kalagher, S.; Turba, U. C.
2013-08-01
PurposeThis study describes and evaluated the effectiveness of occluding distal ureters in the clinical setting of urinary vaginal (vesicovaginal or enterovesicovaginal) fistulae utilizing a new technique which combines Amplatzer vascular plugs and N-butyl cyanoacrylate.MaterialsThis is a retrospective study (January 2007-December 2010) of patients with urinary-vaginal fistulae undergoing distal ureter embolization utilizing an Amplatzer- N-butyl cyanoacrylate-Amplatzer sandwich technique. An 8-12-mm type-I or type-II Amplatzer vascular plug was delivered using the sheath and deployed in the ureter distal to the pelvic brim. Instillation of 0.8-1.5 cc of N-butyl cyanoacrylate into ureter proximal to the Amplatzer plug was performed. This was followed bymore » another set of 8-12-mm type-I or type-II Amplatzer vascular plugs in a technique referred to as the 'sandwich technique.'ResultsFive ureters in three patients were occluded utilizing the above-described technique during the 4-year study period. Mean maximum size Amplatzer used per ureter was 10.8 mm (range, 8-12). One ureter required three Amplatzer plugs and the rest required two. Two patients (3 ureters) were clinically successful with complete resolution of symptoms in 36-48 h. The third patient (2 ureters) was partly successful and required a second Amplatzer- N-butyl cyanoacrylate sandwich technique embolization. The mean clinical follow-up was 11.3 months (range, 1.7-29.2).ConclusionsThe Amplatzer- N-butyl cyanoacrylate-Amplatzer sandwich technique for occluding the distal ureter is safe and effective with a quick (probably due to the N-butyl cyanoacrylate) and durable (probably due to the Amplatzer plugs) clinical response.« less
Volkan, Ender; Ford, Bradley A; Pinkner, Jerome S; Dodson, Karen W; Henderson, Nadine S; Thanassi, David G; Waksman, Gabriel; Hultgren, Scott J
2012-06-12
P pili are prototypical chaperone-usher pathway-assembled pili used by Gram-negative bacteria to adhere to host tissues. The PapC usher contains five functional domains: a transmembrane β-barrel, a β-sandwich Plug, an N-terminal (periplasmic) domain (NTD), and two C-terminal (periplasmic) domains, CTD1 and CTD2. Here, we delineated usher domain interactions between themselves and with chaperone-subunit complexes and showed that overexpression of individual usher domains inhibits pilus assembly. Prior work revealed that the Plug domain occludes the pore of the transmembrane domain of a solitary usher, but the chaperone-adhesin-bound usher has its Plug displaced from the pore, adjacent to the NTD. We demonstrate an interaction between the NTD and Plug domains that suggests a biophysical basis for usher gating. Furthermore, we found that the NTD exhibits high-affinity binding to the chaperone-adhesin (PapDG) complex and low-affinity binding to the major tip subunit PapE (PapDE). We also demonstrate that CTD2 binds with lower affinity to all tested chaperone-subunit complexes except for the chaperone-terminator subunit (PapDH) and has a catalytic role in dissociating the NTD-PapDG complex, suggesting an interplay between recruitment to the NTD and transfer to CTD2 during pilus initiation. The Plug domain and the NTD-Plug complex bound all of the chaperone-subunit complexes tested including PapDH, suggesting that the Plug actively recruits chaperone-subunit complexes to the usher and is the sole recruiter of PapDH. Overall, our studies reveal the cooperative, active roles played by periplasmic domains of the usher to initiate, grow, and terminate a prototypical chaperone-usher pathway pilus.
TAKETOMI, SHUJI; INUI, HIROSHI; NAKAMURA, KENSUKE; YAMAGAMI, RYOTA; TAHARA, KEITARO; SANADA, TAKAKI; MASUDA, HIRONARI; TANAKA, SAKAE; NAKAGAWA, TAKUMI
2015-01-01
Purpose the efficacy and safety of using a suspensory button for femoral fixation in anatomical anterior cruciate ligament (ACL) reconstruction with bone-patellar tendon-bone (BPTB) graft have not been established. The purpose of the current study was to evaluate bone plug integration onto the femoral socket and migration of the bone plug and the EndoButton (EB) (Smith & Nephew, Andover, MA, USA) after rectangular tunnel ACL reconstruction with BPTB autograft. Methods thirty-four patients who underwent anatomical rectangular ACL reconstruction with BPTB graft using EB for femoral fixation and in whom three-dimensional (3D) computed tomography (CT) was performed one week and one year after surgery were included in this study. Bone plug integration onto the femoral socket, bone plug migration, soft tissue interposition, EB migration and EB rotation were evaluated on 3D CT. The clinical outcome was also assessed and correlated with the imaging outcomes. Results the bone plug was integrated onto the femoral socket in all cases. The incidence of bone plug migration, soft tissue interposition, EB migration and EB rotation was 15, 15, 9 and 56%, respectively. No significant association was observed between the imaging outcomes. The postoperative mean Lysholm score was 97.1 ± 5.0 points. The postoperative side-to-side difference, evaluated using a KT-2000 arthrometer, averaged 0.5 ± 1.3 mm. There were no complications associated with EB use. Imaging outcomes did not affect the postoperative KT side-to-side difference. Conclusions the EB is considered a reliable device for femoral fixation in anatomical rectangular tunnel ACL reconstruction with BPTB autograft. Level of evidence Level IV, therapeutic case series. PMID:26889465
Tau, Noam; Atar, Eliyahu; Mei-Zahav, Meir; Bachar, Gil N; Dagan, Tamir; Birk, Einat; Bruckheimer, Elchanan
2016-08-01
Coil embolization of pulmonary arteriovenous malformations (PAVMs) has a high re-canalization/re-perfusion rate. Embolization with Amplatzer plugs has been previously described, but the long-term efficacy is not established. This study reports the experience of a referral medical center with the use of coils and Amplatzer plugs for treating PAVMs in patients with hereditary hemorrhagic telangiectasia. The study was approved by the Institutional Review Board with waiver of informed consent. The cohort included all patients who underwent PAVM embolization in 2004-2014 for whom follow-up imaging scans were available. The medical files were retrospectively reviewed for background data, embolization method (coils, Amplatzer plugs, both), and complications. Re-canalization of treated PAVMs was assessed from intrapulmonary angiograms (following percutaneous procedures) or computed tomography angiograms. Fisher's exact test and Pearson Chi-squared test or t test were used for statistical analysis, with significance at p < 0.05. 16 patients met the study criteria. Imaging scans were available for 63 of the total 110 PAVMs treated in 41 procedures. Coils were used for embolization in 37 PAVMs, Amplatzer plugs in 21, and both in five. Median follow-up time was 7.7 years (range 1.4-18.9). Re-canalization was detected in seven vessels, all treated with coils; there were no cases of re-canalization in plug-occluded vessels (p = 0.0413). The use of Amplatzer plugs for the embolization of PAVMs in patients with hemorrhagic telangiectasia is associated with a significantly lower rate of re-canalization of feeding vessels than coils. Long-term prospective studies are required to confirm these findings.
Udho, Eshwar; Jakes, Karen S.; Finkelstein, Alan
2012-01-01
TonB-dependent transporters (TBDTs), which transport iron-chelating siderophores and vitamin B12 across the outer membrane of gram negative bacteria, share a conserved architecture of a 22-stranded beta-barrel with an amino-terminal plug domain occluding the barrel. We previously reported that we could induce TBDTs to reversibly open in planar lipid bilayers via the use of urea and that these channels were responsive to physiological concentrations of ligands. Here we report that in the presence of urea, trypsin can cleave the amino-terminal 67 residues of the plug of the TonB-dependent transporter FhuA, as assessed by gel shift and mass spectrometry assays. On the bilayer, trypsin treatment in the presence of urea resulted in the induced conductance no longer being reversed upon removal of urea, suggesting that urea opens intact FhuA channels by pulling the plug at least partly out of the barrel, and that removal of the urea then allows reinsertion of the plug into the barrel. When expressed separately, the FhuA plug domain was found to be a mostly unfolded structure that was able to occlude isolated FhuA beta-barrels inserted into the membrane. Thus, although folded in the barrel, the plug need not be folded upon exiting the barrel. The rate of insertion of the beta-barrels into the membrane was tremendously increased in the presence of an osmotic gradient provided by either urea or glycerol. Negative staining electron microscopy showed that FhuA in a detergent solution formed vesicles, thus explaining why an osmotic gradient promoted the insertion of FhuA into membranes. PMID:22846061
Plug and Play PV Systems for American Homes
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hoepfner, Christian
2016-12-22
The core objectives of the Plug & Play PV Systems Project were to develop a PV system that can be installed on a residential rooftop for less than $1.50/W in 2020, and in less than 10 hours (from point of purchase to commissioning). The Fraunhofer CSE team’s approach to this challenge involved a holistic approach to system design – hardware and software – that make Plug & Play PV systems: • Quick, easy, and safe to install • Easy to demonstrate as code compliant • Permitted, inspected, and interconnected via an electronic process Throughout the three years of work duringmore » this Department of Energy SunShot funded project, the team engaged in a substantive way with inspectional services departments and utilities, manufacturers, installers, and distributors. We received iterative feedback on the system design and on ideas for how such systems can be commercialized. This ultimately led us to conceiving of Plug & Play PV Systems as a framework, with a variety of components compatible with the Plug & Play PV approach, including string or microinverters, conventional modules or emerging lightweight modules. The framework enables a broad group of manufacturers to participate in taking Plug & Play PV Systems to market, and increases the market size for such systems. Key aspects of the development effort centered on the system hardware and associated engineering work, the development of a Plug & Play PV Server to enable the electronic permitting, inspection and interconnection process, understanding the details of code compliance and, on occasion, supporting applications for modifications to the code to allow lightweight modules, for example. We have published a number of papers on our testing and assessment of novel technologies (e.g., adhered lightweight modules) and on the electronic architecture.« less
Pierce, Aaron R.; King, Sammy L.
2011-01-01
Channelization of streams associated with floodplain forested wetlands has occurred extensively throughout the world and specifically in the southeastern United States. Channelization of fluvial systems alters the hydrologic and sedimentation processes that sustain these systems. In western Tennessee, channelization and past land-use practices have caused drastic geomorphic and hydrologic changes, resulting in altered habitat conditions that may affect avian communities. The objective of this study was to determine if there were differences in avian communities utilizing floodplain forests along unchannelized streams compared to channelized streams with valley plugs, areas where sediment has completely filled the channel. During point count surveys, 58 bird species were observed at unchannelized sites and 60 species were observed at valley plug sites. Species associated with baldcypress-tupelo (Taxodium-Nyssa) swamps (e.g. Great Egret (Ardea albus) and Black-crowned Night Heron (Nycticorax nycticorax)) and mature hardwood forests with open midstories (e.g. Eastern Wood-Pewee (Contopus virens), Yellow-throated Vireo (Vireo flavifrons), Cerulean Warbler (Dendroica cerulea) and Scarlet Tanager (Piranga olivacea)) were either only found at unchannelized sites or were more abundant at unchannelized sites. Conversely, species associated with open and early successional habitats (e.g. Tree Swallow (Tachycineta bicolor), Northern Mockingbird (Mimus polyglottos) and Blue Grosbeak (Passerina caerulea)) were either only found at valley plug sites or were more abundant at valley plug sites. Results of habitat modelling suggest that the habitat characteristics of floodplain forests at unchannelized sites are more suitable for Neotropical migrant bird species of conservation concern in the region than at valley plug sites. This study, in combination with previous research, demonstrates the ecological impacts of valley plugs span across abiotic and biotic processes and tropic levels.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tau, Noam, E-mail: taunoam@gmail.com; Atar, Eliyahu; Mei-Zahav, Meir
PurposeCoil embolization of pulmonary arteriovenous malformations (PAVMs) has a high re-canalization/re-perfusion rate. Embolization with Amplatzer plugs has been previously described, but the long-term efficacy is not established. This study reports the experience of a referral medical center with the use of coils and Amplatzer plugs for treating PAVMs in patients with hereditary hemorrhagic telangiectasia.MethodsThe study was approved by the Institutional Review Board with waiver of informed consent. The cohort included all patients who underwent PAVM embolization in 2004–2014 for whom follow-up imaging scans were available. The medical files were retrospectively reviewed for background data, embolization method (coils, Amplatzer plugs, both),more » and complications. Re-canalization of treated PAVMs was assessed from intrapulmonary angiograms (following percutaneous procedures) or computed tomography angiograms. Fisher’s exact test and Pearson Chi-squared test or t test were used for statistical analysis, with significance at p < 0.05.Results16 patients met the study criteria. Imaging scans were available for 63 of the total 110 PAVMs treated in 41 procedures. Coils were used for embolization in 37 PAVMs, Amplatzer plugs in 21, and both in five. Median follow-up time was 7.7 years (range 1.4–18.9). Re-canalization was detected in seven vessels, all treated with coils; there were no cases of re-canalization in plug-occluded vessels (p = 0.0413).ConclusionThe use of Amplatzer plugs for the embolization of PAVMs in patients with hemorrhagic telangiectasia is associated with a significantly lower rate of re-canalization of feeding vessels than coils. Long-term prospective studies are required to confirm these findings.« less
Qin, Yuxuan; Shang, Qingmao; Zhang, Ying; Li, Pinglan; Chai, Yunrong
2017-01-01
Vegetable plug seedling has become the most important way to produce vegetable seedlings in China. This seedling method can significantly improve the quality and yield of vegetables compared to conventional methods. In the process of plug seedling, chemical fertilizers or pesticides are often used to improve the yield of the seedlings albeit with increasing concerns. Meanwhile, little is known about the impact of beneficial bacteria on the rhizosphere microbiota and the growth conditions of vegetables during plug seedling. In this study, we applied a culture-independent next-generation sequencing-based approach and investigated the impact of a plant beneficial bacterium, Bacillus amyloliquefaciens L-S60, on the composition and dynamics of rhizosphere microbiota and the growth conditions of cucumbers during plug seedling. Our results showed that application of L-S60 significantly altered the structure of the bacterial community associated with the cucumber seedling; presence of beneficial rhizosphere species such as Bacillus, Rhodanobacter, Paenibacillus, Pseudomonas, Nonomuraea, and Agrobacterium was higher upon L-S60 treatment than in the control group. We also measured the impact of L-S60 application on the physiological properties of the cucumber seedlings as well as the availability of main mineral elements in the seedling at different time points during the plug seedling. Results from those measurements indicated that L-S60 application promoted growth conditions of cucumber seedlings and that more available mineral elements were detected in the cucumber seedlings from the L-S60 treated group than from the control group. The findings in this study provided evidence for the beneficial effects of plant growth-promoting rhizosphere bacteria on the bacterial community composition and growth conditions of the vegetables during plug seedling. PMID:29312278
Insensitive Munitions (Les Munitions a Risque Attenue)
1992-07-01
hydrocar- a banana plug connector attached to the bon and silicone oils resulted in such a high ground wire that would be attached during friction load...had a banana diameter upper electrode rod passed through plug connector attached to the high voltage the nylon insulator. It was much longer (350...mm deep so that it hole was put through the center of the could accept a banana plug attached to the propellant contact to enable acceptance of a
[Dampness in an electric plug as a cause of electricity failure in an operation theatre].
Andersen, C; Pold, R; Nielsen, H D
2000-02-07
Two cases of electricity failure in an operation theatre during open heart surgery are discussed. The fuse for the patient monitor, ventilator, surgery instruments and heart lung machine was blown. Short-circuit was established because of humidity in the plug of the heater for fluid and blood. We recommend sealed or founded plugs and that anaesthesia equipment should not be used as an electrical supply for other electronic apparatus.
NASA Technical Reports Server (NTRS)
Straight, D. M.; Harrington, D. E.
1973-01-01
A concept for plug nozzles cooled by inlet ram air is presented. Experimental data obtained with a small scale model, 21.59-cm (8.5-in.) diameter, in a static altitude facility demonstrated high thrust performance and excellent pumping characteristics. Tests were made at nozzle pressure ratios simulating supersonic cruise and takeoff conditions. Effect of plug size, outer shroud length, and varying amounts of secondary flow were investigated.
Performance characteristics of an isolated coannular plug nozzle at transonic speeds
NASA Technical Reports Server (NTRS)
Mercer, C. E.; Burley, J. R., II
1985-01-01
The Langley 16-Foot Transonic Tunnel was used to evaluate the performance characteristics of a coannular plug nozzle at static conditions (Mach number of 0) and at Mach numbers from 0.65 to 1.20. Jet total pressure ratio was varied from 1.0 (jet off) to 10.0. Thirty-seven configurations generated by the combination of three geometric variables - plug angle, shroud boattail length (fixed exit radius), and shroud extension length - were tested.
Niemann, Ralph C.; Gonczy, John D.; Nicol, Thomas H.
1987-01-01
A cryogenic support member is comprised of a non-metallic rod having a depression in at least one end and a metallic end connection assembled to the rod. The metallic end connection comprises a metallic plug which conforms to the shape and is disposed in the depression and a metallic sleeve is disposed over the rod and plug. The plug and the sleeve are shrink-fitted to the depression in the rod to form a connection good in compression, tension and bending.
Airway reopening through catastrophic events in a hierarchical network
Baudoin, Michael; Song, Yu; Manneville, Paul; Baroud, Charles N.
2013-01-01
When you reach with your straw for the final drops of a milkshake, the liquid forms a train of plugs that flow slowly initially because of the high viscosity. They then suddenly rupture and are replaced with a rapid airflow with the characteristic slurping sound. Trains of liquid plugs also are observed in complex geometries, such as porous media during petroleum extraction, in microfluidic two-phase flows, or in flows in the pulmonary airway tree under pathological conditions. The dynamics of rupture events in these geometries play the dominant role in the spatial distribution of the flow and in determining how much of the medium remains occluded. Here we show that the flow of a train of plugs in a straight channel is always unstable to breaking through a cascade of ruptures. Collective effects considerably modify the rupture dynamics of plug trains: Interactions among nearest neighbors take place through the wetting films and slow down the cascade, whereas global interactions, through the total resistance to flow of the train, accelerate the dynamics after each plug rupture. In a branching tree of microchannels, similar cascades occur along paths that connect the input to a particular output. This divides the initial tree into several independent subnetworks, which then evolve independently of one another. The spatiotemporal distribution of the cascades is random, owing to strong sensitivity to the plug divisions at the bifurcations. PMID:23277557
Effect of beam channel plugging on the outcome of gamma knife radiosurgery for trigeminal neuralgia
DOE Office of Scientific and Technical Information (OSTI.GOV)
Massager, Nicolas; Nissim, Ouzi; Murata, Noriko
2006-07-15
Purpose: We studied the influence of using plugs for brainstem protection during gamma knife radiosurgery (GKR) of trigeminal neuralgia (TN), with special emphasis on irradiation doses delivered to the trigeminal nerve, pain outcomes, and incidence of trigeminal dysfunction. Methods and Materials: A GKR procedure for TN using an anterior cisternal target and a maximum dose of 90 Gy was performed in 109 patients. For 49 patients, customized beam channel blocking (plugs) were used to reduce the dose delivered to the brainstem. We measured the mean and integrated radiation doses delivered to the trigeminal nerve and the clinical course of patientsmore » treated with and without plugs. Results: We found that blocking increases the length of trigeminal nerve exposed to high-dose radiation, resulting in a significantly higher mean dose to the trigeminal nerve. Significantly more of the patients with blocking achieved excellent pain outcomes (84% vs. 62%), but with higher incidences of moderate and bothersome trigeminal nerve dysfunction (37% mild/10% bothersome with plugs vs. 30% mild/2% bothersome without). Conclusions: The use of plugs to protect the brainstem during GKR treatment for TN increases the dose of irradiation delivered to the intracisternal trigeminal nerve root and is associated with an important increase in the incidence of trigeminal nerve dysfunction. Therefore, beam channel blocking should be avoided for 90 Gy-GKR of TN.« less
May, Thomas W.; Brumbaugh, William G.
2007-01-01
This report presents the results of a study by the U.S. Geological Survey, done in cooperation with the U.S. Bureau of Reclamation, to determine mercury concentrations in whole-body fish and fish muscle plugs from the South Fork of the Humboldt River near Elko in the Te-Moak Indian Reservation. A single muscle plug was collected from beneath the dorsal fin area in each of the three whole-body fish samples. After homogenization and lyophilization of the muscle plugs and whole-body fish samples, mercury concentrations were determined with a direct mercury analyzer utilizing the process of thermal combustion-gold amalgamation atomic absorption spectroscopy. Mercury concentrations in whole-body fish ranged from 0.048 to 0.061 microgram per gram wet weight, and 0.061 to 0.082 microgram per gram wet weight in muscle plugs. All sample mercury concentrations were well below the U.S. Environmental Protection Agency's fish consumption advisory of 0.30 microgram per gram wet weight.
Kawaguchi, Tomohiro; Arakawa, Kazuya; Nomura, Kazuhiro; Ogawa, Yoshikazu; Katori, Yukio; Tominaga, Teiji
2017-12-01
Endoscopic endonasal surgery, an innovative surgical technique, is used to approach sinus lesions, lesions of the skull base, and intradural tumors. The cooperation of experienced otolaryngologists and neurosurgeons is important to achieve safe and reliable surgical results. The bath plug closure method is a treatment option for patients with cerebrospinal fluid(CSF)leakage. Although it includes dural and/or intradural procedures, surgery tends to be performed by otolaryngologists because its indications, detailed maneuvers, and pitfalls are not well recognized by neurosurgeons. We reviewed the cases of patients with CSF leakage treated by using the bath plug closure method with an endoscopic endonasal approach at our institution. Three patients were treated using the bath plug closure method. CSF leakage was caused by a meningocele in two cases and trauma in one case. No postoperative intracranial complications or recurrence of CSF leakage were observed. The bath plug closure method is an effective treatment strategy and allows neurosurgeons to gain in-depth knowledge of the treatment options for CSF leakage by using an endoscopic endonasal approach.
Henken, Rachel L.; Chantiwas, Rattikan; Gilman, S. Douglass
2012-01-01
Significant changes in the formation and retention of magnetic bead plugs in a capillary during electrophoresis were studied, and it was demonstrated that these effects were due to the type of biological molecule immobilized on the surface of these beads. Three biological molecules, an antibody, an oligonucleotide and alkaline phosphatase, were attached to otherwise identical streptavidin-coated magnetic beads through biotin-avidin binding in order to isolate differences in bead immobilization in a magnetic field resulting from the type of biological molecule immobilized on the bead surface. Alkaline phosphatase also was attached to the magnetic beads using epoxy groups on the bead surfaces (instead of avidin-biotin binding) to study the impact of immobilization chemistry. The formation and retention of magnetic bead plugs were studied quantitatively using light scattering detection of magnetic particles eluting from the bead plugs and qualitatively using microscopy. Both the type of biomolecule immobilized on the magnetic bead surface and the chemistry used to link the biomolecule to the magnetic bead impacted the formation and retention of the bead plugs. PMID:22437880
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pech, Maciej, E-mail: maciej.pech@med.ovgu.de; Mohnike, Konrad; Wieners, Gero
2011-10-15
Purpose: We describe our initial clinical experience in artificial embolization with the Amplatzer Vascular Plug IV (VP IV), a further development of the Vascular Plug family already in routine use. Methods: Results from 50 embolization procedures conducted with the VP IV in 44 patients are summarized. Results: All 50 embolizations were successful, although two required the technique to be modified because of problems with jamming of the screw thread and thus with disconnection of the plug. This was associated with large branching angles. Conclusions: With experience, the VP IV can be used safely and effectively, and it expands the spectrummore » of possible embolizations in interventional radiology. Its greatest disadvantage is its relatively poor positional controllability.« less
Defect specific maintenance of SG tubes -- How safe is it?
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cizelj, L.; Mavko, B.; Dvorsek, T.
1997-02-01
The efficiency of the defect specific plugging criterion for outside diameter stress corrosion cracking at tube support plates is assessed. The efficiency is defined by three parameters: (1) number of plugged tubes, (2) probability of steam generator tube rupture and (3) predicted accidental leak rate through the defects. A probabilistic model is proposed to quantify the probability of tube rupture, while procedures available in literature were used to define the accidental leak rates. The defect specific plugging criterion was then compared to the performance of traditional (45%) plugging criterion using realistic data from Krsko nuclear power plant. Advantages of themore » defect specific approach over the traditional one are clearly shown. Some hints on the optimization of safe life of steam generator are also given.« less
Acute Delamination of Commercially Available Decellularized Osteochondral Allograft Plugs
Degen, Ryan M.; Tetreault, Danielle; Mahony, Greg T.; Williams, Riley J.
2016-01-01
Articular cartilage injuries, and corresponding surgical procedures, are occurring with increasing frequency as identified by a review of recent surgical trends. Concerns have grown in recent years regarding the longevity of results following microfracture, with a shift toward cartilage restoration procedures in recent years. This case report describes 2 cases of acute failure following the use of commercially available osteochondral allograft plugs used for the treatment of osteochondral defects of the distal femur. In both cases the chondral surface of the plug delaminated from the underlying cancellous bone, resulting in persistent pain and swelling requiring reoperation and removal of the loose fragments. Caution should be employed when considering use of these plugs for the treatment of osteochondral lesions, as similar outcomes have not been noted with other cartilage restoration techniques. PMID:27688840
NASA Technical Reports Server (NTRS)
Janardan, B. A.; Brausch, J. F.; Price, A. O.
1984-01-01
Acoustic and diagnostic data that were obtained to determine the influence of selected geometric and aerodynamic flow variables of coannular nozzles with thermal acoustic shields are summarized in this comprehensive data report. A total of 136 static and simulated flight acoustic test points were conducted with 9 scale-model nozzles The tested nozzles included baseline (unshielded), 180 deg shielded, and 360 deg shielded dual flow coannular plug configurations. The baseline configurations include a high radius ratio unsuppressed coannular plug nozzle and a coanuular plug nozzle and a coannular plug nozzle with a 20-chute outer stream suppressor. The tests were conducted at nozzle temperatures and pressure typical of operating conditions of variable cycle engine.
Bagless transfer process and apparatus for radioactive waste confinement
Maxwell, D.N.; Hones, R.H.; Rogers, M.L.
1998-04-14
A process and apparatus are provided for removing radioactive material from a glovebox, placing the material in a stainless steel storage vessel in communication with the glovebox, and sealing the vessel with a welded plug. The vessel is then severed along the weld, a lower half of the plug forming a closure for the vessel. The remaining welded plug half provides a seal for the remnant portion of the vessel and thereby maintains the sealed integrity of the glovebox. 7 figs.
Bagless transfer process and apparatus for radioactive waste confinement
Maxwell, David N.; Hones, Robert H.; Rogers, M. Lane
1998-01-01
A process and apparatus is provided for removing radioactive material from a glovebox, placing the material in a stainless steel storage vessel in communication with the glovebox, and sealing the vessel with a welded plug. The vessel is then severed along the weld, a lower half of the plug forming a closure for the vessel. The remaining welded plug half provides a seal for the remnant portion of the vessel and thereby maintains the sealed integrity of the glovebox.
Amplatzer vascular plug as an embolic agent in different vascular pathologies: A pictorial essay
Tresley, Jonathan; Bhatia, Shivank; Kably, Issam; Poozhikunnath Mohan, Prasoon; Salsamendi, Jason; Narayanan, Govindarajan
2016-01-01
The Amplatzer Vascular Plug (AVP) is a cylindrical plug made of self-expanding nitinol wire mesh with precise delivery control, which can be used for a variety of vascular pathologies. An AVP is an ideal vascular occlusion device particularly in high-flow vessels, where there is high risk of migration and systemic embolization with traditional occlusion devices. We performed 28 embolizations using the AVP from 2009 to 2014 and achieved complete occlusion without complications. PMID:27413276
Preliminary Investigation of Methods to Increase Base Pressure of Plug Nozzles at Mach 0.9
NASA Technical Reports Server (NTRS)
Salmi, Reino J
1956-01-01
The effects of various afterbody changes on the base pressure of a nacelle-type isentropic plug nozzle installation operating at lower-than-design jet pressure ratios were investigated at a Mach number of 0.9. Although the estimates of the net propulsive force contain some uncertainties, the results indicate that both a plain-ring base shroud and a circular-arc boattail fairing reduced the loss in net propulsive force experienced with a cylindrical nacelle installation of the plug nozzle.
Strategies for Controlling Plug Loads. A Tool for Reducing Plug Loads in Commercial Buildings
DOE Office of Scientific and Technical Information (OSTI.GOV)
Torcellini, Paul; Bonnema, Eric; Sheppy, Michael
2015-09-01
Plug loads are often not considered as part of the energy savings measures in Commercial Buildings; however, they can account for up to 50% of the energy used in the building. These loads are numerous and often scattered throughout a building. Some of these loads are purchased by the owner and some designed into the building or the tenant finishes for a space. This document provides a strategy and a tool for minimizing these loads.
Public Key-Based Need-to-Know Authorization Engine Final Report CRADA No. TSB-1553-98
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mark, R.; Williams, R.
The goals of this project were to develop a public key-based authentication service plug-in based on LLNL's requirements, integrate the public key-based authentication with the Intra Verse authorization service adn the LLNL NTK server by developing a full-featured version of the prototyped Intra Verse need-to-know plug in; and to test the authorization and need-to-know plug-in in a secured extranet prototype among selected national Labs.
Guneyli, Serkan; Cinar, Celal; Bozkaya, Halil; Parildar, Mustafa; Oran, Ismail; Akin, Yigit
2012-12-01
Congenital portosystemic venous shunt is extremely rare and should be treated. Advances in treatment techniques allow for patients to be treated safely. We present a 9-year-old boy with a large congenital portosystemic venous shunt. The shunt was occluded interventionally with the Amplatzer vascular plug II. Our case was unique with its clinical manifestation, the use of a 22-mm Amplatzer vascular plug II, and the presence of the patient's 1-year follow-up.
Plug-in electric vehicles: future market conditions and adoption rates
2017-01-01
This report, the first of four Issues in Focus articles from the International Energy Outlook 2017, analyzes the effects of uncertainties in the adoption of plug-in electric vehicles (PEVs) on worldwide transportation energy consumption. Uncertainties surrounding consumer acceptance, vehicle cost, policies, and other market conditions could affect future adoption rates of plug-in electric vehicles. Two side cases are presented in this report that assume different levels of PEV adoption and result in different levels of worldwide transportation energy consumption.
[APPLICATION OF FISTULA PLUG WITH THE FIBRIN ADHESIVE IN TREATMENT OF RECTAL FISTULAS].
Aydinova, P R; Aliyev, E A
2015-05-01
Results of surgical treatment of 21 patients, suffering high transsphincteric and extrasphincteric rectal fistulas, were studied. In patients of Group I the fistula passage was closed, using fistula plug obturator; and in patients of Group II--by the same, but preprocessed by fibrin adhesive. The fistula aperture germeticity, prophylaxis of rude cicatrices development in operative wound zone, promotion of better fixation of bioplastic material were guaranteed, using fistula plug obturator with preprocessing, using fibrin adhesive.
Quasi-Porous Plug With Vortex Chamber
NASA Technical Reports Server (NTRS)
Walsh, J. V.
1985-01-01
Pressure-letdown valve combines quasi-porous-plug and vortex-chamber in one controllable unit. Valve useful in fossil-energy plants for reducing pressures in such erosive two-phase process streams as steam/water, coal slurries, or combustion gases with entrained particles. Quasi-Porous Plug consists of plenums separated by perforated plates. Number or size of perforations increases with each succeeding stage to compensate for expansion. In Vortex Chamber, control flow varies to control swirl and therefore difference between inlet and outlet pressures.
Spatial dynamics of overbank sedimentation in floodplain systems
Pierce, Aaron R.; King, S.L.
2008-01-01
Floodplains provide valuable social and ecological functions, and understanding the rates and patterns of overbank sedimentation is critical for river basin management and rehabilitation. Channelization of alluvial systems throughout the world has altered hydrological and sedimentation processes within floodplain ecosystems. In the loess belt region of the Lower Mississippi Alluvial Valley of the United States, channelization, the geology of the region, and past land-use practices have resulted in the formation of dozens of valley plugs in stream channels and the formation of shoals at the confluence of stream systems. Valley plugs completely block stream channels with sediment and debris and can result in greater deposition rates on floodplain surfaces. Presently, however, information is lacking on the rates and variability of overbank sedimentation associated with valley plugs and shoals. We quantified deposition rates and textures in floodplains along channelized streams that contained valley plugs and shoals, in addition to floodplains occurring along an unchannelized stream, to improve our understanding of overbank sedimentation associated with channelized streams. Feldspar clay marker horizons and marker poles were used to measure floodplain deposition from 2002 to 2005 and data were analyzed with geospatial statistics to determine the spatial dynamics of sedimentation within the floodplains. Mean sediment deposition rates ranged from 0.09 to 0.67??cm/y at unchannelized sites, 0.16 to 2.27??cm/y at shoal sites, and 3.44 to 6.20??cm/y at valley plug sites. Valley plug sites had greater rates of deposition, and the deposited sediments contained more coarse sand material than either shoal or unchannelized sites. A total of 59 of 183 valley plug study plots had mean deposition rates > 5??cm/y. The geospatial analyses showed that the spatial dynamics of sedimentation can be influenced by the formation of valley plugs and shoals on channelized streams; however, responses can vary. Restoration efforts in the region need to have basinwide collaboration with landowners and address catchment-scale processes, including the geomorphic instability of the region, to be successful. ?? 2008 Elsevier B.V. All rights reserved.
Methodology for Mechanical Property Testing on Fuel Cladding Using an Expanded Plug Wedge Test
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang, Jy-An John; Jiang, Hao
To determine the tensile properties of irradiated fuel cladding in a hot cell, a simple test was developed at ORNL and is described fully in US Patent Application 20060070455, Expanded plug method for developing circumferential mechanical properties of tubular materials. This method is designed for testing fuel rod cladding ductility in a hot cell utilizing an expandable plug to stretch a small ring of irradiated cladding material. The specimen strain is determined using the measured diametrical expansion of the ring. This method removes many complexities associated with specimen preparation and testing. The advantages are the simplicity of measuring the testmore » component assembly in the hot cell and the direct measurement of specimen strain. It was also found that cladding strength could be determined from the test results. The basic approach of this test method is to apply an axial compressive load to a cylindrical plug of polyurethane (or other materials) fitted inside a short ring of the test material to achieve radial expansion of the specimen. The diameter increase of the specimen is used to calculate the circumferential strain accrued during the test. The other two basic measurements are total applied load and amount of plug compression (extension). A simple procedure is used to convert the load circumferential strain data from the ring tests into material pseudo-stress-strain curves. However, several deficiencies exist in this expanded-plug loading ring test, which will impact accuracy of test results and introduce potential shear failure of the specimen due to inherited large axial compressive stress from the expansion plug test. First of all, the highly non-uniform stress and strain distribution resulted in the gage section of the clad. To ensure reliable testing and test repeatability, the potential for highly non-uniform stress distribution or displacement/strain deformation has to be eliminated at the gage section of the specimen. Second, significant compressive stresses were induced by clad bending deformation due to a clad bulging effect (or the barreling effect). The barreling effect caused very large localized shear stress in the clad and left testing material at a high risk of shear failure. The above combined effects will result in highly non-conservative predictions both in strength and ductility of the tested clad, and the associated mechanical properties as well. To overcome/mitigate the mentioned deficiencies associated with the current expansion plug test, systematic studies have been conducted. Through detailed parameter investigation on specific geometry designs, careful filtering of material for the expansion plug, as well as adding newly designed parts to the testing system, a method to reconcile the potential non-conservatism embedded in the expansion plug test system has been discovered. A modified expansion plug testing protocol has been developed based on the method. In order to closely resemble thin-wall theory, a general procedure was also developed to determine the hoop stress in the tested ring specimen. A scaling factor called -factor is defined to correlate the ring load P into hoop stress . , = . The generated stress-strain curve agrees very well with tensile test data in both the elastic and plastic regions.« less
40 CFR 147.3011 - Plugging and abandonment of Class III wells.
Code of Federal Regulations, 2010 CFR
2010-07-01
...) WATER PROGRAMS (CONTINUED) STATE, TRIBAL, AND EPA-ADMINISTERED UNDERGROUND INJECTION CONTROL PROGRAMS Lands of the Navajo, Ute Mountain Ute, and All Other New Mexico Tribes § 147.3011 Plugging and...
Ghanem, Omar M; Abu Dayyeh, Barham K; Kellogg, Todd A
2017-10-01
Gastropleural fistula (GPF) is a serious complication after bariatric surgery. Multiple treatment modalities including pharmacologic, endoscopic, and revisional surgery have been proposed. We present a case of a GPF managed successfully with a laparoendoscopic approach utilizing a fistula plug. A 43-year-old male patient presented with a GPF after a revisional bariatric surgery. A laparoendoscopic approach including lysis of adhesions, identification of the fistula, plugging the fistula with a BioGore A® fistula plug, placement an enteric stent, placement of a feeding tube, and surgical drainage was performed. The multimedia video illustrates the technique used. Postoperatively, upper gastrointestinal (UGI) imaging showed no evidence of leak. The enteric stent was removed after 2 months after verifying complete healing of the fistula. A laparoendoscopic approach to GPF repair with the use of fistula plug is effective, safe, and feasible.
Cryogenic insulation strength and bond tester
NASA Technical Reports Server (NTRS)
Schuerer, P. H.; Ehl, J. H.; Prasthofer, W. P. (Inventor)
1985-01-01
A method and apparatus for testing the tensile strength and bonding strength of sprayed-on foam insulation attached to metal cryogenic fuel tanks is described. A circular cutter is used to cut the insulation down to the surface of the metal tank to form plugs of the insulation for testing in situ on the tank. The apparatus comprises an electromechanical pulling device powered by a belt battery pack. The pulling device comprises a motor driving a mechanical pulling structure comprising a horizontal shaft connected to two bell cracks which are connected to a central member. When the lower end of member is attached to a fitting, which in turn is bonded to a plug, a pulling force is exerted on the plug sufficient to rupture it. The force necessary to rupture the plug or pull it loose is displayed as a digital read-out.
Revascularization and Apical Plug in an Immature Molar
Roghanizadeh, Leyla; Fazlyab, Mahta
2018-01-01
Managing of necrotic permanent teeth with immature apices is a treatment challenges. Treatment of such teeth includes apexification, apical plug and more recently, revascularization technique with the probable advantage of continuation of root development. In the present case report the referred patient had discomfort with a necrotic immature mandibular first molar. Periapical radiography showed a rather large apical lesion around immature roots. Revascularization protocol using calcium-enriched mixture (CEM) cement was indicated for the mesial root. However, in distal canal apical plug technique was applied. At 2-year follow-up, both procedures were successful in relieving patient’s symptoms. Dentin formation and increase in length of the mesial root was obvious. Apical plug and revascularization technique proved to be successful in management of necrotic immature teeth; moreover, revascularization carried the advantage of continuation of root development. PMID:29692851
Superfluid helium 2 liquid-vapor phase separation: Technology assessment
NASA Technical Reports Server (NTRS)
Lee, J. M.
1984-01-01
A literature survey of helium 2 liquid vapor phase separation is presented. Currently, two types of He 2 phase separators are being investigated: porous, sintered metal plugs and the active phase separator. The permeability K(P) shows consistency in porous plug geometric characterization. Both the heat and mass fluxes increase with K(P). Downstream pressure regulation to adjust for varying heat loads and both temperatures is possible. For large dynamic heat loads, the active phase separator shows a maximum heat rejection rate of up to 2 W and bath temperature stability of 0.1 mK. Porous plug phase separation performance should be investigated for application to SIRTF and, in particular, that plugs of from 10 to the minus ninth square centimeters to 10 to the minus eighth square centimeters in conjunction with downstream pressure regulation be studied.
NASA Astrophysics Data System (ADS)
Vijayamohan, Prithvi
As oil/gas subsea fields mature, the amount of water produced increases significantly due to the production methods employed to enhance the recovery of oil. This is true especially in the case of oil reservoirs. This increase in the water hold up increases the risk of hydrate plug formation in the pipelines, thereby resulting in higher inhibition cost strategies. A major industry concern is to reduce the severe safety risks associated with hydrate plug formation, and significantly extending subsea tieback distances by providing a cost effective flow assurance management/safety tool for mature fields. Developing fundamental understanding of the key mechanistic steps towards hydrate plug formation for different multiphase flow conditions is a key challenge to the flow assurance community. Such understanding can ultimately provide new insight and hydrate management guidelines to diminish the safety risks due to hydrate formation and accumulation in deepwater flowlines and facilities. The transportability of hydrates in pipelines is a function of the operating parameters, such as temperature, pressure, fluid mixture velocity, liquid loading, and fluid system characteristics. Specifically, the hydrate formation rate and plugging onset characteristics can be significantly different for water continuous, oil continuous, and partially dispersed systems. The latter is defined as a system containing oil/gas/water, where the water is present both as a free phase and partially dispersed in the oil phase (i.e., entrained water in the oil). Since hydrate formation from oil dispersed in water systems and partially dispersed water systems is an area which is poorly understood, this thesis aims to address some key questions in these systems. Selected experiments have been performed at the University of Tulsa flowloop to study the hydrate formation and plugging characteristics for the partially dispersed water/oil/gas systems as well as systems where the oil is completely dispersed in water. These experiments indicate that the partially dispersed systems tend to be problematic and are more severe cases with respect to flow assurance when compared to systems where the water is completely dispersed in oil. We have found that the partially dispersed systems are distinct, and are not an intermediate case between water dominated, and water-in-oil emulsified systems. Instead the experiments indicate that the hydrate formation and plugging mechanism for these systems are very complex. Hydrate growth is very rapid for such systems when compared to 100% water cut systems. The plugging mechanism for these systems is a combination of various phenomena (wall growth, agglomeration, bedding/settling, etc). Three different oils with different viscosities have been used to investigate the transportability of hydrates with respect to oil properties. The experiments indicate that the transportability of hydrates increases with increase in oil viscosity. The data from the tests performed provide the basis for a mechanistic model for hydrate formation and plugging in partially dispersed systems. It is found that in systems that were in stratified flow regime before hydrate onset, the hydrates eventually settled on the pipe walls thereby decreasing the flow area for the flow of fluids. In systems that were in the slug flow regime before hydrate formation, moving beds of hydrates were the main cause for plugging. In both the flow regimes, the systems studied entered a plugging regime beyond a certain hydrate concentration. This is termed as φplugging onset and can be used as an indicator to calculate the amount of hydrates that can be transported safely without requiring any additional treatment for a given set of flow characteristics. A correlation to calculate this hydrate concentration based on easily accessible parameters is developed in terms of flow characteristics and oil properties. The work performed in this thesis has enhanced the understanding of the hydrate plug mechanism in pipelines having high amounts of water. This work has also shown the effect of hydrate formation in different flow regimes thereby shedding light on the effects of hydrates on multiphase flow and vice versa. Lessons resulting from this work could be incorporated into flow assurance models, as well as operating company production strategies to reduce or mitigate hydrate plugging risks in complex multiphase systems.
Salt Plug Formation Caused by Decreased River Discharge in a Multi-channel Estuary
Shaha, Dinesh Chandra; Cho, Yang-Ki
2016-01-01
Freshwater input to estuaries may be greatly altered by the river barrages required to meet human needs for drinking water and irrigation and prevent salt water intrusion. Prior studies have examined the salt plugs associated with evaporation and salt outwelling from tidal salt flats in single-channel estuaries. In this work, we discovered a new type of salt plug formation in the multi-channel Pasur River Estuary (PRE) caused by decreasing river discharges resulting from an upstream barrage. The formation of a salt plug in response to changes in river discharge was investigated using a conductivity-temperature-depth (CTD) recorder during spring and neap tides in the dry and wet seasons in 2014. An exportation of saline water from the Shibsa River Estuary (SRE) to the PRE through the Chunkhuri Channel occurred during the dry season, and a salt plug was created and persisted from December to June near Chalna in the PRE. A discharge-induced, relatively high water level in the PRE during the wet season exerted hydrostatic pressure towards the SRE from the PRE and thereby prevented the intrusion of salt water from the SRE to the PRE. PMID:27255892
Progress on ITER Diagnostic Integration
NASA Astrophysics Data System (ADS)
Johnson, David; Feder, Russ; Klabacha, Jonathan; Loesser, Doug; Messineo, Mike; Stratton, Brentley; Wood, Rick; Zhai, Yuhu; Andrew, Phillip; Barnsley, Robin; Bertschinger, Guenter; Debock, Maarten; Reichle, Roger; Udintsev, Victor; Vayakis, George; Watts, Christopher; Walsh, Michael
2013-10-01
On ITER, front-end components must operate reliably in a hostile environment. Many will be housed in massive port plugs, which also shield the machine from radiation. Multiple diagnostics reside in a single plug, presenting new challenges for developers. Front-end components must tolerate thermally-induced stresses, disruption-induced mechanical loads, stray ECH radiation, displacement damage, and degradation due to plasma-induced coatings. The impact of failures is amplified due to the difficulty in performing robotic maintenance on these large structures. Motivated by needs to minimize disruption loads on the plugs, standardize the handling of shield modules, and decouple the parallel efforts of the many parties, the packaging strategy for diagnostics has recently focused on the use of 3 vertical shield modules inserted from the plasma side into each equatorial plug structure. At the front of each is a detachable first wall element with customized apertures. Progress on US equatorial and upper plugs will be used as examples, including the layout of components in the interspace and port cell regions. Supported by PPPL under contract DE-AC02-09CH11466 and UT-Battelle, LLC under contract DE-AC05-00OR22725 with the U.S. DOE.
33 CFR 154.106 - Incorporation by reference.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 20, Switzerland. (1) IEC 60309-1 Plugs, Socket-Outlets and Couplers for Industrial Purposes—Part 1: General Requirements, Edition 4.2 2012-06, IBR approved for § 154.2102(b). (2) IEC 60309-2 Plugs, Socket...
40 CFR 211.210-2 - Labeling requirements.
Code of Federal Regulations, 2010 CFR
2010-07-01
... constant); (ii) Ear cup volume or shape; (iii) Mounting of ear cup on head band; (iv) Ear cushion; (v... tension (spring constant); (ii) Mounting of plug on head band; (iii) Shape of plug; (iv) Material...
Apparatus tube configuration and mounting for solid oxide fuel cells
Zymboly, G.E.
1993-09-14
A generator apparatus is made containing long, hollow, tubular, fuel cells containing an inner air electrode, an outer fuel electrode, and solid electrolyte there between, placed between a fuel distribution board and a board which separates the combustion chamber from the generating chamber, where each fuel cell has an insertable open end and in insertable, plugged, closed end, the plugged end being inserted into the fuel distribution board and the open end being inserted through the separator board where the plug is completely within the fuel distribution board. 3 figures.
Optimal control of a repowered vehicle: Plug-in fuel cell against plug-in hybrid electric powertrain
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tribioli, L., E-mail: laura.tribioli@unicusano.it; Cozzolino, R.; Barbieri, M.
2015-03-10
This paper describes two different powertrain configurations for the repowering of a conventional vehicle, equipped with an internal combustion engine (ICE). A model of a mid-sized ICE-vehicle is realized and then modified to model both a parallel plug-in hybrid electric powertrain and a proton electrolyte membrane (PEM) fuel cell (FC) hybrid powertrain. The vehicle behavior under the application of an optimal control algorithm for the energy management is analyzed for the different scenarios and results are compared.
DOE Office of Scientific and Technical Information (OSTI.GOV)
None, None
The U.S. Department of Energy and the U.S. Department of Transportation have published a guide to highlight examples of federal support and technical assistance for plug-in electric vehicles (PEVs) and charging stations. The guide provides a description of each opportunity and a point of contact to assist those interested in advancing PEV technology. The Department of Energy’s Alternative Fuels Data Center provides a comprehensive database of federal and state programs that support plug-in electric vehicles and infrastructure.
The Elimination of Fire Hazard Due to Back Fires
NASA Technical Reports Server (NTRS)
Theodorsen, Theodore; Freeman, Ira M
1933-01-01
A critical study was made of the operation of a type of back-fire arrester used to reduce the fire hazard of aircraft engines. A flame arrester consisting of a pack or plug of alternate flat and corrugated plates of thin metal was installed in the intake pipe of a gasoline engines; an auxiliary spark plug inserted in the intake manifold permitted the production of artificial back fires at will. It was found possible to design a plug which prevented all back fires from reaching the carburetor.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Schey, Stephen; Francfort, Jim
This report focuses on the NASA White Sands Test Facility (WSTF) fleet to identify daily operational characteristics of select vehicles and report findings on vehicle and mission characterizations to support the successful introduction of plug-in electric vehicles (PEVs) into the agencies’ fleets. Individual observations of these selected vehicles provide the basis for recommendations related to electric vehicle adoption and whether a battery electric vehicle (BEV) or plug-in hybrid electric vehicle (PHEV) (collectively plug-in electric vehicles, or PEVs) can fulfill the mission requirements.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Schey, Stephen; Francfort, Jim
2014-11-01
This report focuses on the National Institute of Health (NIH) fleet to identify daily operational characteristics of select vehicles and report findings on vehicle and mission characterizations to support the successful introduction of plug-in electric vehicles (PEVs) into the agencies’ fleets. Individual observations of these selected vehicles provide the basis for recommendations related to electric vehicle adoption and whether a battery electric vehicle (BEV) or plug-in hybrid electric vehicle (PHEV) (collectively plug-in electric vehicles, or PEVs) can fulfill the mission requirements.
Kubota, Hisashi; Sanada, Yasuhiro; Murakami, Saori; Miyauchi, Masaharu; Iwakura, Michihiro; Nagatsuka, Kazuhiro; Furukawa, Kentaro; Kato, Amami; Fujita, Mitsugu
2017-01-01
The demand of a burr hole surgery for chronic subdural hematoma (CSDH) is increasing in the global aging society. Burr hole-derived autologous bone dusts are not associated with extra costs compared with other commonly used synthetic materials. In addition, postoperative calvarium ossification requires periosteum-mediated blood supply, which is lacking after using avascular synthetic materials. Based on these findings, we hypothesized that the combination of the bone plugs and the preserved periosteum during burr hole surgeries for CSDH would induce efficient calvarium ossification. We evaluated the long-term effects of bone plugs on the degree of ossification and cosmetic appearance of the skin covering the burr hole sites. We included 8 patients (9 burr holes) who received the autologous bone dust derived from burr holes. As the control group, 9 burr holes that did not receive any burr hole plugs were retrospectively selected. These burr holes were evaluated by computed tomography (CT) scan for the calvarium defect ratios, CT value-based ossification, and the degree of skin sinking. Ossification was observed in all the bone plugs by the bone density CT scans; they maintained their volume at 12 months after the surgeries. The calvarium defect ratios (volume ratios of the unossified parts in the burr holes) gradually increased during the first 6 months and reached 0.44 at 12 months. The mean CT values also increased from 527 HU to 750 HU for the first 6 months and reached 905 HU at 12 months. The degrees of skin sinking at the burr hole sites with the bone plugs were 1.24 mm whereas those without the bone plugs were 2.69 mm ( P = 0.004). Application of burr hole-derived autologous bone dust is associated with better ossification and objective cosmetic result following burr hole surgery after CSDH.
Maximizing the Benefits of Plug-in Electric Vehicles - Continuum Magazine
Testing and Integration Facility. Photo by Dennis Schroeder, NREL Maximizing the Benefits of Plug-in . Electric vehicle charging stations in NREL's parking garage. Photo by Dennis Schroder, NREL An NREL
16 CFR 307.6 - Requirements for disclosure on the label.
Code of Federal Regulations, 2010 CFR
2010-01-01
..., plug of chewing tobacco, or dispenser of individual packages of smokeless tobacco that may be purchased... plug of chewing tobacco—Eight point type, provided that if the warning statement is printed in one line...
Plug-and-play initiative : phase II : final report.
DOT National Transportation Integrated Search
2017-01-01
Clear Roads has undertaken an initiative to establish a Plug-and-Play protocol that fosters interoperability between various winter maintenance equipment and a point location (central office). This report documents the data types and communication me...
Garcilazo-Cruz, Uriel; Alvarez-Padilla, Fernando
2015-01-01
Abstract Reproduction in arthropods is an interesting area of research where intrasexual and intersexual mechanisms have evolved structures with several functions. The mating plugs usually produced by males are good examples of these structures where the main function is to obstruct the female genitalia against new sperm depositions. In spiders several types of mating plugs have been documented, the most common ones include solidified secretions, parts of the bulb or in some extraordinary cases the mutilation of the entire palpal bulb. Here, we describe the first case of modified setae, which are located on the cymbial dorsal base, used directly as a mating plug for the Order Araneae in the species Maeota setastrobilaris sp. n. In addition the taxonomic description of Maeota setastrobilaris sp. n. is provided and based on our findings the geographic distribution of this genus is extended to the Northern hemisphere. PMID:26175601
Bae, Taehan; Atkins, Robert A; Taylor, Henry F; Gibler, William N
2003-02-20
Pressure sensing in an internal combustion engine with an intrinsic fiber Fabry-Perot interferometer (FFPI) integrated with a spark plug is demonstrated for the first time. The spark plug was used for the ignition of the cylinder in which it was mounted. The FFPI element, protected with a copper/gold coating, was embedded in a groove in the spark-plug housing. Gas pressure inthe engine induced longitudinal strain in this housing, which was also experienced by the fiber-optic sensing element. The sensor was monitored with a signal conditioning unit containing a chirped distributed-feedback laser. Pressure sensitivities as high as 0.00339 radians round-trip phase shift per pounds per square inch of pressure were observed. Measured pressure versus time traces showed good agreement with those from a piezoelectric reference sensor mounted in the same engine cylinder.
Susceptibility-matched plugs for microcoil NMR probes
NASA Astrophysics Data System (ADS)
Kc, Ravi; Gowda, Yashas N.; Djukovic, Danijel; Henry, Ian D.; Park, Gregory H. J.; Raftery, Daniel
2010-07-01
For mass-limited samples, the residual sample volume outside the detection coil is an important concern, as is good base line resolution. Here, we present the construction and evaluation of magnetic susceptibility-matched plugs for microcoil NMR sample cells which address these issues. Mixed-epoxy glue and ultem tube plugs that have susceptibility values close to those of perfluorocarbon FC-43 (fluorinert) and copper were used in small volume (0.5-2 μL) and larger volume (15-20 μL) thin glass capillary sample cells. Using these plugs, the sample volume efficiency (i.e. ratio of active volume to total sample volume in the microcoil NMR cell) was improved by 6-12-fold without sensitivity and resolution trade-offs. Comparison with laser etched or heat etched microcoil sample cells is provided. The approaches described are potentially useful in metabolomics for biomarkers detection in mass limited biological samples.
Susceptibility-matched plugs for microcoil NMR probes.
Kc, Ravi; Gowda, Yashas N; Djukovic, Danijel; Henry, Ian D; Park, Gregory H J; Raftery, Daniel
2010-07-01
For mass-limited samples, the residual sample volume outside the detection coil is an important concern, as is good base line resolution. Here, we present the construction and evaluation of magnetic susceptibility-matched plugs for microcoil NMR sample cells which address these issues. Mixed-epoxy glue and ultem tube plugs that have susceptibility values close to those of perfluorocarbon FC-43 (fluorinert) and copper were used in small volume (0.5-2 microL) and larger volume (15-20 microL) thin glass capillary sample cells. Using these plugs, the sample volume efficiency (i.e. ratio of active volume to total sample volume in the microcoil NMR cell) was improved by 6-12-fold without sensitivity and resolution trade-offs. Comparison with laser etched or heat etched microcoil sample cells is provided. The approaches described are potentially useful in metabolomics for biomarkers detection in mass limited biological samples. Copyright (c) 2010 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Bae, Taehan; Atkins, Robert A.; Taylor, Henry F.; Gibler, William N.
2003-02-01
Pressure sensing in an internal combustion engine with an intrinsic fiber Fabry-Perot interferometer (FFPI) integrated with a spark plug is demonstrated for the first time. The spark plug was used for the ignition of the cylinder in which it was mounted. The FFPI element, protected with a copper /gold coating, was embedded in a groove in the spark-plug housing. Gas pressure in the engine induced longitudinal strain in this housing, which was also experienced by the fiber-optic sensing element. The sensor was monitored with a signal conditioning unit containing a chirped distributed-feedback laser. Pressure sensitivities as high as 0.00339 radians round-trip phase shift per pounds per square inch of pressure were observed. Measured pressure versus time traces showed good agreement with those from a piezoelectric reference sensor mounted in the same engine cylinder.
Romero, Juan A [Albuquerque, NM; Walker, Charles A [Albuquerque, NM; Blair, Dianna S [Albuquerque, NM; Bodmer, Connie C [Albuquerque, NM
2012-05-29
Seals have a flexible wire that can be looped through a hasp-like device. The seals include a body having a recess, a plug insertable into the recess and a snap ring for fastening the plug to the body. The plug and/or body can have access holes for inserting the wire into the recess. "Teeth" on the outer diameter and through-holes through the thickness of the snap ring allow for passing the ends of the flexible wire from the recess through the snap ring. The ends of the wire can be folded back over the snap ring and into engagement with the teeth. Assembly of the seal causes the ends of the wire to be securely fastened between the teeth of the snap ring and the sidewall of the recess. Seals can include a plug and/or body made of a frangible material such as glass, ceramic, glass-ceramic or brittle polymer.
Susceptibility-matched plugs for microcoil NMR probes
Kc, Ravi; Gowda, Yashas N.; Djukovic, Danijel; Henry, Ian D; Park, Gregory H J; Raftery, Daniel
2010-01-01
For mass limited samples, the residual sample volume outside the detection coil is an important concern, as is good base line resolution. Here, we present the construction and evaluation of magnetic susceptibility-matched plugs for microcoil NMR sample cells which address these issues. Mixed-epoxy glue and ultem tube plugs that have susceptibility values close to those of perfluorocarbon FC-43 (fluorinert) and copper were used in small volume (0.5 to 2 μL) and larger volume (15 to 20 μL) thin glass capillary sample cells. Using these plugs, the sample volume efficiency (i.e. ratio of active volume to total sample volume in the microcoil NMR cell) was improved by 6 to 12 fold without sensitivity and resolution trade-offs. Comparison with laser etched or heat etched microcoil sample cells is provided. The approaches described are potentially useful in metabolomics for biomarkers detection in mass limited biological samples. PMID:20510638
Thermal Pyrolytic Graphite Enhanced Components
NASA Technical Reports Server (NTRS)
Hardesty, Robert E. (Inventor)
2015-01-01
A thermally conductive composite material, a thermal transfer device made of the material, and a method for making the material are disclosed. Apertures or depressions are formed in aluminum or aluminum alloy. Plugs are formed of thermal pyrolytic graphite. An amount of silicon sufficient for liquid interface diffusion bonding is applied, for example by vapor deposition or use of aluminum silicon alloy foil. The plugs are inserted in the apertures or depressions. Bonding energy is applied, for example by applying pressure and heat using a hot isostatic press. The thermal pyrolytic graphite, aluminum or aluminum alloy and silicon form a eutectic alloy. As a result, the plugs are bonded into the apertures or depressions. The composite material can be machined to produce finished devices such as the thermal transfer device. Thermally conductive planes of the thermal pyrolytic graphite plugs may be aligned in parallel to present a thermal conduction path.
Analytical and experimental study of axisymmetric truncated plug nozzle flow fields
NASA Technical Reports Server (NTRS)
Muller, T. J.; Sule, W. P.; Fanning, A. E.; Giel, T. V.; Galanga, F. L.
1972-01-01
Experimental and analytical investigation of the flow field and base pressure of internal-external-expansion truncated plug nozzles are discussed. Experimental results for two axisymmetric, conical plug-cylindrical shroud, truncated plug nozzles are presented for both open and closed wake operations. These results include extensive optical and pressure data covering nozzle flow field and base pressure characteristics, diffuser effects, lip shock strength, Mach disc behaviour, and the recompression and reverse flow regions. Transonic experiments for a special planar transonic section are presented. An extension of the analytical method of Hall and Mueller to include the internal shock wave from the shroud exit is presented for closed wake operation. Results of this analysis include effects on the flow field and base pressure of ambient pressure ratio, nozzle geometry, and the ratio of specific heats. Static thrust is presented as a function of ambient pressure ratio and nozzle geometry. A new transonic solution method is also presented.
Flexible Plug Repair for Shuttle Wing Leading Edge
NASA Technical Reports Server (NTRS)
Camarda, Charles J.; Sikora, Joseph; Smith, Russel; Rivers, H.; Scotti, Stephen J.; Fuller, Alan M.; Klacka, Robert; Reinders, Martin; Schwind, Francis; Sullivan, Brian;
2012-01-01
In response to the Columbia Accident Investigation Board report, a plug repair kit has been developed to enable astronauts to repair the space shuttle's wing leading edge (WLE) during orbit. The plug repair kit consists of several 17.78- cm-diameter carbon/silicon carbide (C/SiC) cover plates of various curvatures that can be attached to the refractory carbon-carbon WLE panels using a TZM refractory metal attach mechanism. The attach mechanism is inserted through the damage in the WLE panel and, as it is tightened, the cover plate flexes to conform to the curvature of the WLE panel within 0.050 mm. An astronaut installs the repair during an extravehicular activity (EVA). After installing the plug repair, edge gaps are checked and the perimeter of the repair is sealed using a proprietary material, developed to fill cracks and small holes in the WLE.
Fully optical backplane system using novel optical plug and slot
NASA Astrophysics Data System (ADS)
Cho, In-Kui; Ahn, Seung-Ho; Lee, Woo-Jin; Han, Sang-Pil; Kim, Jin-Tae; Choi, Chun-Ki; Shin, Kyung-Up; Yoon, Keun Byoung; Jeong, Myung-Yung; Park, Hyo Hoon
2005-10-01
A fully optical PCB with transmitter/receiver system boards and optical bakcplane was prepared, which is board-to-board interconnection by an optical slot. We report a 10 Gb/s PRBS NRZ data transmission between transmitter system board and optical backplane embedded multimode polymeric waveguide arrays. The basic concept of the optical PCB is as follows; 1) Metal optical bench is integrated with optoelectronic devices, driver and receiver circuits, polymeric waveguide and access line PCB module. 2) Multimode polymeric waveguide inside an optical backplane, which is embedded into PCB, 3) Optical slot and plug for high-density (channel pitch : 500 um) board-to-board interconnection. The polymeric waveguide technology can be used for transmission of data between transmitter/receiver processing boards and backplane boards. The main components are low-loss tapered polymeric waveguides and a novel optical plug and slot for board-to-board interconnections, respectively. The transmitter/receiver processing boards are designed as plug types, and can be easily plugged-in and -out at an optical backplane board. The optical backplane boards are prepared by employing the lamination processes for conventional electrical PCBs. A practical optical backplane system was implemented with two processing boards and an optical backplane. As connection components between the transmitter/receiver processing boards and backplane board, optical slots made of a 90°-bending structure-embedded optical plug was used. A 10 Gb/s data link was successfully demonstrated. The bit error rate (BER) was determined and is 5.6×10 -9(@10Gb/s) and the BER of 8 Gb/s is < 10 -12.
Round window plugging in the treatment of superior semicircular canal dehiscence.
Succar, Eric F; Manickam, Periakaruppan V; Wing, Sara; Walter, Jeffrey; Greene, Joseph S; Azeredo, William J
2018-06-01
Objectives were to describe the use of round window plugging for superior semicircular canal dehiscence syndrome and review further recommendations regarding the procedure based on our experience and to compare results with recent literature on round window plugging. Retrospective case series. Fourteen patients underwent round window plugging for superior semicircular canal dehiscence at our institution from 2012 to 2015. All patients underwent the same surgical procedure. Available pre- and postoperative data were reviewed. Fourteen patient charts were reviewed. Symptoms of autophony improved in nine of 14 (64%) patients. Symptoms of pressure-induced vertigo improved in seven of 12 (58%) patients. Hennebert's sign that was positive preoperatively only improved in one of six (17%) patients. A positive preoperative vestibular evoked myogenic potential improved in only one of six (17%) patients. Six of 13 (46%) patients had increased air conduction thresholds postoperatively. Round window plugging has been described as a less-invasive treatment for patients with superior semicircular canal dehiscence. Although the procedure did benefit some of our patients, successful outcomes were not predictable. Improvement in at least one objective finding was seen in only 21% of the patients studied. Hennebert's sign and vestibular evoked myogenic potentials that were positive preoperatively only improved in 17% of patients. At our institution, round window plugging is no longer considered a reasonable treatment option for most patients with superior semicircular canal dehiscence. We recommend that further study on this topic follow a standardized pre- and postoperative assessment. 4. Laryngoscope, 128:1445-1452, 2018. © 2017 The American Laryngological, Rhinological and Otological Society, Inc.
Valuation of plug-in vehicle life-cycle air emissions and oil displacement benefits
Michalek, Jeremy J.; Chester, Mikhail; Jaramillo, Paulina; Samaras, Constantine; Shiau, Ching-Shin Norman; Lave, Lester B.
2011-01-01
We assess the economic value of life-cycle air emissions and oil consumption from conventional vehicles, hybrid-electric vehicles (HEVs), plug-in hybrid-electric vehicles (PHEVs), and battery electric vehicles in the US. We find that plug-in vehicles may reduce or increase externality costs relative to grid-independent HEVs, depending largely on greenhouse gas and SO2 emissions produced during vehicle charging and battery manufacturing. However, even if future marginal damages from emissions of battery and electricity production drop dramatically, the damage reduction potential of plug-in vehicles remains small compared to ownership cost. As such, to offer a socially efficient approach to emissions and oil consumption reduction, lifetime cost of plug-in vehicles must be competitive with HEVs. Current subsidies intended to encourage sales of plug-in vehicles with large capacity battery packs exceed our externality estimates considerably, and taxes that optimally correct for externality damages would not close the gap in ownership cost. In contrast, HEVs and PHEVs with small battery packs reduce externality damages at low (or no) additional cost over their lifetime. Although large battery packs allow vehicles to travel longer distances using electricity instead of gasoline, large packs are more expensive, heavier, and more emissions intensive to produce, with lower utilization factors, greater charging infrastructure requirements, and life-cycle implications that are more sensitive to uncertain, time-sensitive, and location-specific factors. To reduce air emission and oil dependency impacts from passenger vehicles, strategies to promote adoption of HEVs and PHEVs with small battery packs offer more social benefits per dollar spent. PMID:21949359
Valuation of plug-in vehicle life-cycle air emissions and oil displacement benefits.
Michalek, Jeremy J; Chester, Mikhail; Jaramillo, Paulina; Samaras, Constantine; Shiau, Ching-Shin Norman; Lave, Lester B
2011-10-04
We assess the economic value of life-cycle air emissions and oil consumption from conventional vehicles, hybrid-electric vehicles (HEVs), plug-in hybrid-electric vehicles (PHEVs), and battery electric vehicles in the US. We find that plug-in vehicles may reduce or increase externality costs relative to grid-independent HEVs, depending largely on greenhouse gas and SO(2) emissions produced during vehicle charging and battery manufacturing. However, even if future marginal damages from emissions of battery and electricity production drop dramatically, the damage reduction potential of plug-in vehicles remains small compared to ownership cost. As such, to offer a socially efficient approach to emissions and oil consumption reduction, lifetime cost of plug-in vehicles must be competitive with HEVs. Current subsidies intended to encourage sales of plug-in vehicles with large capacity battery packs exceed our externality estimates considerably, and taxes that optimally correct for externality damages would not close the gap in ownership cost. In contrast, HEVs and PHEVs with small battery packs reduce externality damages at low (or no) additional cost over their lifetime. Although large battery packs allow vehicles to travel longer distances using electricity instead of gasoline, large packs are more expensive, heavier, and more emissions intensive to produce, with lower utilization factors, greater charging infrastructure requirements, and life-cycle implications that are more sensitive to uncertain, time-sensitive, and location-specific factors. To reduce air emission and oil dependency impacts from passenger vehicles, strategies to promote adoption of HEVs and PHEVs with small battery packs offer more social benefits per dollar spent.
Reinhold, Ann Marie; Poole, Geoffrey C.; Bramblett, Robert G.; Zale, Alexander V.; Roberts, David W.
2018-01-01
Determining the influences of anthropogenic perturbations on side channel dynamics in large rivers is important from both assessment and monitoring perspectives because side channels provide critical habitat to numerous aquatic species. Side channel extents are decreasing in large rivers worldwide. Although riprap and other linear structures have been shown to reduce side channel extents in large rivers, we hypothesized that small “anthropogenic plugs” (flow obstructions such as dikes or berms) across side channels modify whole-river geomorphology via accelerating side channel senescence. To test this hypothesis, we conducted a geospatial assessment, comparing digitized side channel areas from aerial photographs taken during the 1950s and 2001 along 512 km of the Yellowstone River floodplain. We identified longitudinal patterns of side channel recruitment (created/enlarged side channels) and side channel attrition (destroyed/senesced side channels) across n = 17 river sections within which channels were actively migrating. We related areal measures of recruitment and attrition to the density of anthropogenic side channel plugs across river sections. Consistent with our hypothesis, a positive spatial relationship existed between the density of anthropogenic plugs and side channel attrition, but no relationship existed between plug density and side channel recruitment. Our work highlights important linkages among side channel plugs and the persistence and restoration of side channels across floodplain landscapes. Specifically, management of small plugs represents a low-cost, high-benefit restoration opportunity to facilitate scouring flows in side channels to enable the persistence of these habitats over time.
Effect of cloacal plugging on microbial recovery from partially processed broilers.
Musgrove, M T; Cason, J A; Fletcher, D L; Stern, N J; Cox, N A; Bailey, J S
1997-03-01
Experiments were performed to test the contribution of bacteria contained in the intestinal tract of broilers at the beginning of processing to counts on the exterior of modified New York-dressed carcasses. Thirty-two birds were processed for each of seven replications. Within each replication, batches of four birds were electrocuted, scalded, and picked, with batches alternating between treatment and control groups. Treated birds were cloacally plugged with rayon fiber tampons prior to electrocution to prevent escape of intestinal contents during scalding and picking. Control birds were processed in the same manner, except that cloacal plugs were inserted immediately after defeathering to reduce escape of intestinal contents during sampling. Gram-negative enteric bacteria and Campylobacter spp. were enumerated on carcasses by whole carcass rinse procedure and in cecal contents. Counts were converted to log10 and subjected to analysis of variance. Cecal levels of Gram-negative enterics were significantly higher for plugged birds, but there was not a significant difference between levels of cecal Campylobacter spp. between treatment groups. Plugging before electrocution resulted in significantly lower levels (2.5 vs 3.0 log10 cfu/mL) of Campylobacter spp. and Gram-negative enteric bacteria (3.0 vs 3.4 log10 cfu/mL) in carcass rinses of treatment birds than in those of controls. All carcasses were positive for Gram-negative enterics. Cloacal plugging resulted in significantly lower incidence of Campylobacter spp. carcass contamination as determined by chi-square. Intestinal carriage of both campylobacters and Gram-negative enteric bacteria appears to influence the microbial quality of the carcass during processing.
Oscillation of an isolated liquid plug inside a dry capillary
NASA Astrophysics Data System (ADS)
Srinivasan, Vyas; Kumar, Siddhartha; Asfer, Mohammed; Khandekar, Sameer
2017-11-01
The present work reports an experimental study on the dynamics of partially wetting isolated liquid plug (DI water), which is made to oscillate inside a square, glass capillary tube (1 mm × 1 mm; 60 mm length). The liquid plug is made to oscillate pneumatically at two different frequencies (0.25 and 0.35 Hz), using a cam-follower mechanism. Bright field imaging is used to visualize the three-phase contact line behavior, while, micro-Particle Imaging Velocimetry (PIV) apparatus is used to discern the nature of flow inside the oscillating liquid plug. During a cycle, due to the partial wetting nature of DI water, the three-phase contact line at the menisci gets pinned at the extreme end of each stroke, where the dynamic apparent contact angle gets drastically altered before the initiation of the next stroke. The difference between the apparent contact angle of the front and rear meniscus are seen to be a function of the oscillating frequency; the difference increasing with increasing frequency. The flow inside the liquid plug reveals unique non-Poiseuille flow features near the meniscus, due to free-slip boundary condition, which leads to formation of distinct vortex pairs behind it. The vortices too change their direction during each stroke of the oscillation, eventually leading to an alternating recirculation pattern inside the plug. The results clearly indicate that improved mathematical models are required for predicting transport parameters in such flows, which are important in engineering systems such as pulsating heat pipes, lab-on-chip devices and PEM fuel cells.
Evaluation of Asphalt Bridge Deck Joint Systems.
DOT National Transportation Integrated Search
2009-12-01
Asphaltic Plug Joint is an expansion joint that is used for new and rehabilitated bridges. It provides a smooth and watertight surface free of debris; and offers simple, easy and staged construction. Asphaltic plug joint can be repaired segmentally a...
46 CFR 39.10-5 - Incorporation by reference-TB/ALL.
Code of Federal Regulations, 2010 CFR
2010-10-01
..., 1 rue de Varembé, Geneva, Switzerland IEC 309-1—Plugs, Socket-Outlets and Couplers for Industrial Purposes: Part 1, General Requirements, 1979 39.20-9 IEC 309-2—Plugs, Socket-Outlets and Couplers for...
46 CFR 39.10-5 - Incorporation by reference-TB/ALL.
Code of Federal Regulations, 2012 CFR
2012-10-01
..., 1 rue de Varembé, Geneva, Switzerland IEC 309-1—Plugs, Socket-Outlets and Couplers for Industrial Purposes: Part 1, General Requirements, 1979 39.20-9 IEC 309-2—Plugs, Socket-Outlets and Couplers for...
46 CFR 39.10-5 - Incorporation by reference-TB/ALL.
Code of Federal Regulations, 2011 CFR
2011-10-01
..., 1 rue de Varembé, Geneva, Switzerland IEC 309-1—Plugs, Socket-Outlets and Couplers for Industrial Purposes: Part 1, General Requirements, 1979 39.20-9 IEC 309-2—Plugs, Socket-Outlets and Couplers for...
Dual-Drive Production Prototype Project
DOT National Transportation Integrated Search
2009-06-01
This project was an initiative to engineer, develop and build a plug-in hybrid-electric vehicle using the Dual-Drive system. The project aimed to build a plug-in hybrid utilitarian vehicle on a light commercial vehicle platform. The hybrid vehicle wi...
U.S., Pennsylvania Collaborate on Well-Plugging Case to Protect Drinking Water
A case that led to prison and fines for an operator who improperly plugged old oil wells in the Allegheny Forest in Elk County, Pennsylvania, began when EPA’s Dave Rectenwald noticed something amiss.
30 CFR 250.1715 - How must I permanently plug a well?
Code of Federal Regulations, 2010 CFR
2010-07-01
... in the intervals. (10) Permafrost areas (i) A fluid to be left in the hole that has a freezing point below the temperature of the permafrost, and a treatment to inhibit corrosion; and(ii) Cement plugs...
Collaborative WorkBench for Researchers - Work Smarter, Not Harder
NASA Technical Reports Server (NTRS)
Ramachandran, Rahul; Kuo, Kwo-sen; Maskey, Manil; Lynnes, Christopher
2014-01-01
It is important to define some commonly used terminology related to collaboration to facilitate clarity in later discussions. We define provisioning as infrastructure capabilities such as computation, storage, data, and tools provided by some agency or similarly trusted institution. Sharing is defined as the process of exchanging data, programs, and knowledge among individuals (often strangers) and groups. Collaboration is a specialized case of sharing. In collaboration, sharing with others (usually known colleagues) is done in pursuit of a common scientific goal or objective. Collaboration entails more dynamic and frequent interactions and can occur at different speeds. Synchronous collaboration occurs in real time such as editing a shared document on the fly, chatting, video conference, etc., and typically requires a peer-to-peer connection. Asynchronous collaboration is episodic in nature based on a push-pull model. Examples of asynchronous collaboration include email exchanges, blogging, repositories, etc. The purpose of a workbench is to provide a customizable framework for different applications. Since the workbench will be common to all the customized tools, it promotes building modular functionality that can be used and reused by multiple tools. The objective of our Collaborative Workbench (CWB) is thus to create such an open and extensible framework for the Earth Science community via a set of plug-ins. Our CWB is based on the Eclipse [2] Integrated Development Environment (IDE), which is designed as a small kernel containing a plug-in loader for hundreds of plug-ins. The kernel itself is an implementation of a known specification to provide an environment for the plug-ins to execute. This design enables modularity, where discrete chunks of functionality can be reused to build new applications. The minimal set of plug-ins necessary to create a client application is called the Eclipse Rich Client Platform (RCP) [3]; The Eclipse RCP also supports thousands of community-contributed plug-ins, making it a popular development platform for many diverse applications including the Science Activity Planner developed at JPL for the Mars rovers [4] and the scientific experiment tool Gumtree [5]. By leveraging the Eclipse RCP to provide an open, extensible framework, a CWB supports customizations via plug-ins to build rich user applications specific for Earth Science. More importantly, CWB plug-ins can be used by existing science tools built off Eclipse such as IDL or PyDev to provide seamless collaboration functionalities.
DOT National Transportation Integrated Search
2018-02-02
This research project explores the plug-in electric vehicle (PEV) market, including both Battery Electric Vehicles (BEVs) and Plug-in Hybrid Electric Vehicles (PHEVs), and the sociodemographic characteristics of purchasing households. We use detailed...
46 CFR 52.01-50 - Fusible plugs (modifies A-19 through A-21).
Code of Federal Regulations, 2013 CFR
2013-10-01
... (30 psig), if fired with solid fuel not in suspension, or if not equipped for unattended waterbed... back Scotch boilers, 2 inches above the top row of tubes. (j) [Reserved] (k)(1) Fusible plugs shall be...
Choosing Wisely When It Comes to Eye Care: Antibiotics for Eye Injections
... Antibiotics for eye injections; and Punctal plugs for dry eye . This is the fourth in a series of ... why patients and their ophthalmologists should discuss treating dry eye with punctal plugs only after other treatment options ...
Apparatus tube configuration and mounting for solid oxide fuel cells
Zymboly, Gregory E.
1993-01-01
A generator apparatus (10) is made containing long, hollow, tubular, fuel cells containing an inner air electrode (64), an outer fuel electrode (56), and solid electrolyte (54) therebetween, placed between a fuel distribution board (29) and a board (32) which separates the combustion chamber (16) from the generating chamber (14), where each fuel cell has an insertable open end and in insertable, plugged, closed end (44), the plugged end being inserted into the fuel distribution board (29) and the open end being inserted through the separator board (32) where the plug (60) is completely within the fuel distribution board (29).
Innovations for ISS Plug-In Plan (IPiP) Operations
NASA Technical Reports Server (NTRS)
Moore, Kevin D.
2013-01-01
Limited resources and increasing requirements will continue to influence decisions on ISS. The ISS Plug-In Plan (IPiP) supports power and data for utilization, systems, and daily operations through the Electrical Power System (EPS) Secondary Power/Data Subsystem. Given the fluid launch schedule, the focus of the Plug-In Plan has evolved to anticipate future requirements by judicious development and delivery of power supplies, power strips, Alternating Current (AC) power inverters, along with innovative deployment strategies. A partnership of ISS Program Office, Engineering Directorate, Mission Operations, and International Partners poses unique solutions with existing on-board equipment and resources.
Cho, Y K; Chang, N-K; Ma, J S
2009-05-01
Patent ductus venosus is a rare form of congenital portosystemic shunt from the fetal umbilical vein to the inferior vena cava. The reported surgical treatments include ligation, banding, and liver transplantation. In addition, transcatheter closure with a coil, stent, or original Amplatzer vascular plug (AVP) has been reported. The AVP II, a redesigned version of the original vascular plug with a finer more densely woven nitinol wire and a large diameter (up to 22 mm) is available. This reported case is the first successful occlusion of a large patent ductus venosus with the new AVP II.
Method for preventing plugging in the pyrolysis of agglomerative coals
Green, Norman W.
1979-01-23
To prevent plugging in a pyrolysis operation where an agglomerative coal in a nondeleteriously reactive carrier gas is injected as a turbulent jet from an opening into an elongate pyrolysis reactor, the coal is comminuted to a size where the particles under operating conditions will detackify prior to contact with internal reactor surfaces while a secondary flow of fluid is introduced along the peripheral inner surface of the reactor to prevent backflow of the coal particles. The pyrolysis operation is depicted by two equations which enable preselection of conditions which insure prevention of reactor plugging.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Schey, Stephen; Francfort, Jim
This report focuses on the Sleeping Bear Dunes National Lakeshore (SLBE) fleet to identify daily operational characteristics of select vehicles and report findings on vehicle and mission characterizations to support the successful introduction of plug-in electric vehicles (PEVs) into the agencies’ fleets. Individual observations of these selected vehicles provide the basis for recommendations related to electric vehicle adoption and whether a battery electric vehicle (BEV) or plug-in hybrid electric vehicle (PHEV) (collectively plug-in electric vehicles, or PEVs) can fulfill the mission requirements.
[Unfixed Mesh Plug Migration from Inguinal Ring to Urinary Bladder].
Okada, Koichi; Nakayama, Jiro; Adachi, Shiro; Miyake, Osamu
2018-02-01
A 65-year-old man presented to a clinic with a chief complaint of macrohematuria and frequent urination. The computed tomographic scan and cystoscopy revealed a dome of bladder tumor. He was referred to our hospital with the diagnosis of bladder tumor. He had undergone bilateral inguinal hernia repair and magnetic resonance imaging suggested mesh plug migration on the urinary bladder inserted into the right inguinal lesion 11 years previously. Under the diagnosis of mesh plug migration, partial cystectomy with extraction of the foreign body was performed. After the surgery he was well and symptoms had disappeared.
Continuous pile discharging machine
Smith, Phillips P.
1976-05-11
A device for discharging cartridges from tubes under fluid pressure includes a cylindrical housing adapted to be seated in a leak-tight manner on the end of one of the tubes, a chute depending from the cylindrical housing near the end seated on the end of the tube, a rotatable piston having a wrench on the forward end thereof disposed in the cylindrical housing and adapted to manipulate a plug in the end of the tube, and a telescopic hydraulic ram adapted to move the piston toward the plug. In addition the wrench contains a magnet which prevents inadvertent uncoupling of the wrench and the plug.
Bobkiewicz, Adam; Krokowicz, Łukasz; Borejsza-Wysocki, Maciej; Banasiewicz, Tomasz
2017-08-31
Anal fistula (AF) is a pathological connection between anus and skin in its surroundings. The main reason for the formation of anal fistula is a bacterial infection of the glands within the anal crypts. One of the modern techniques for the treatment of fistulas that do not interfere with the sphincters consists in implantation of a plug made from collagen material. We are presenting the first Polish experience with a new model of biomaterial plug for the treatment of anal fistula. We also point out key elements of the procedure (both preoperative and intraoperative) associated with this method. In the authors' opinion, the method is simple, safe and reproducible. Innovative shape of the plug minimizes the risk of its migration and rotation. It also perfectly blends with and adapts to the course and shape of the fistula canal, allowing it to become incorporated and overgrown with tissue in the fistula canal. The relatively short operation time, minor postoperative pain and faster convalescence are with no doubt additional advantages of the method. Long-term observation involving more patients is essential for evaluation of the efficacy of the treatment of fistulas with the new type of plug.
Failure investigations of failed valve plug SS410 steel due to cracking
NASA Astrophysics Data System (ADS)
Kalyankar, V. D.; Deshmukh, D. D.
2017-12-01
Premature and sudden in service failure of a valve plug due to crack formation, applied in power plant has been investigated. The plug was tempered and heat treated, the crack was originated at centre, developed along the axis and propagates radially towards outer surface of plug. The expected life of the component is 10-15 years while, the component had failed just after the installation that is, within 3 months of its service. No corrosion products were observed on the crack interface and on the failed surface; hence, causes of corrosion failure are neglected. This plug of level separator control valve, is welded to the stem by means of plasma-transferred arc welding and as there is no crack observed at the welding zone, the failure due to welding residual stresses are also neglected. The failed component discloses exposed surface of a crack interface that originated from centre and propagates radially. The micro-structural observation, hardness testing, and visual observation are carried out of the specimen prepared from the failed section and base portion. The microstructure from the cracked interface showed severe carbide formation along the grain boundaries. From the microstructural analysis of the failed sample, it is observed that there is a formation of acicular carbides along the grain boundaries due to improper tempering heat treatment.
Jet noise suppression by porous plug nozzles
NASA Technical Reports Server (NTRS)
Bauer, A. B.; Kibens, V.; Wlezien, R. W.
1982-01-01
Jet noise suppression data presented earlier by Maestrello for porous plug nozzles were supplemented by the testing of a family of nozzles having an equivalent throat diameter of 11.77 cm. Two circular reference nozzles and eight plug nozzles having radius ratios of either 0.53 or 0.80 were tested at total pressure ratios of 1.60 to 4.00. Data were taken both with and without a forward motion or coannular flow jet, and some tests were made with a heated jet. Jet thrust was measured. The data were analyzed to show the effects of suppressor geometry on nozzle propulsive efficiency and jet noise. Aerodynamic testing of the nozzles was carried out in order to study the physical features that lead to the noise suppression. The aerodynamic flow phenomena were examined by the use of high speed shadowgraph cinematography, still shadowgraphs, extensive static pressure probe measurements, and two component laser Doppler velocimeter studies. The different measurement techniques correlated well with each other and demonstrated that the porous plug changes the shock cell structure of a standard nozzle into a series of smaller, periodic cell structures without strong shock waves. These structures become smaller in dimension and have reduced pressure variations as either the plug diameter or the porosity is increased, changes that also reduce the jet noise and decrease thrust efficiency.
Twenty Years of "Plug-and-Pond" Meadow Restoration: A Geomorphic Review
NASA Astrophysics Data System (ADS)
Natali, J.
2015-12-01
Channel incision has degraded the ecological function of wet meadows across montane regions of California. Conservation groups estimate that half of the Sierra Nevada's 333,000 acres of meadow are entrenched in a degraded state that is characterized by a shift from groundwaterfed, herbaceous vegetation to more sparse, droughttolerant woody vegetation. My poster will present results of field research on a prominent restoration technique in California's montane meadows, the "PlugandPond." Fundamentally, the technique rechannelizes the meadow by blocking flow into incised stream channels. Spoils dug from meadow sediments plug the incised channel, creating ponds as a byproduct. One of three approaches to rechannelization ensues: (1) construct a new shallow and sinuous channel, (2) redirect flows into a remnant channel, (3) or allow the channel to define itself over the meadow floodplain. Re channelization aims to support overbank flows at 1.5 to 3 year recurrence intervals. Field surveys of ten of the oldest "plug-and-pond" meadow restoration projects in California reveal that channel bed degradation caused by meadow-scale changes to channel slope (i.e. culverts concentrating flows, channel straightening, meadow grazing) may be more conducive to intensive restoration approaches like Plug-and-Pond.
Device for controlling the pouring of molten materials
Moore, A.F.; Duncan, A.L.
1994-02-15
A device is described for controlling the pouring of a molten material from a crucible or other container. The device includes an annular retainer ring for mounting in the drain opening in the bottom of a conventional crucible, the retainer ring defining a opening there through. The device also includes a plug member having an annular forward end portion for force-fit reception in the opening of the retainer ring to selectively seal the opening and for being selectively forced through the opening. The plug member has a rear end portion for being positioned within the crucible, the rear end portion including stop means for prohibiting the rear end portion from passing through the opening in the retainer ring when the forward end portion is selectively forced through the opening. The plug member defines at least one, and preferably a plurality of flutes, each extending from a point rearward the annular forward end portion of the plug member, and forward the stop means, to a point rearward of the stop means. The flutes permit fluid communication between the interior and exterior of the crucible when the forward end portion of the plug member is forced through the opening in the retaining ring such that the molten material is allowed to flow from the crucible. 5 figures.
OROSCO, Fernando Accorsi; BRAMANTE, Clovis Monteiro; GARCIA, Roberto Brandão; BERNARDINELI, Norberti; de MORAES, Ivaldo Gomes
2010-01-01
Objective This study used dye leakage assay and scanning electron microscopy to evaluate, respectively, the sealing ability and marginal adaptation of three root-end filling materials used as apical plugs, as well as the possible correlation between these properties. Material and Methods Ninety-eight single-rooted human teeth were prepared to simulate an open apex. The teeth were allocated to three experimental groups (n = 30), which received a 5-mm thick apical plug of (1) gray MTA AngelusTM, (2) CPMTM and (3) MBPc, and two controls groups (n = 4). After immersion in 0.2% Rhodamine B solution for 48 h, the teeth were sectioned longitudinally and analyzed by Image Tool 3.0 software. The marginal adaptation between apical plugs and the root canal walls were analyzed by SEM. Results MBPc had significantly less (p<0.05) apical leakage than the other materials. Regarding marginal adaptation, CPMTM showed the best numerical results, though without statistical significance from the other materials (p<0.05). There was no correlation between the two properties. Conclusions When used as apical plugs, the tested root-end filling materials had similar marginal adaptation to the dentin walls, but MBPc had the best sealing ability, as demonstrated by the least apical leakage from all tested materials. PMID:20485923
Prenatal surgery for congenital diaphragmatic hernia.
Au-Yeung, Jeff Ying-Kit; Chan, Kwong-Leung
2003-10-01
Congenital diaphragmatic hernia (CDH) has a mortality rate of up to 77% despite optimal pre- and postnatal care. Fetuses with liver herniation, a low lung-to-head ratio, and an early diagnosis before 24 weeks have a particularly poor prognosis. In utero open repair of these fetuses does not improve patient survival. The PLUG (Plug the Lung Until it Grows) technique was reported to be able to reverse pulmonary hypoplasia in CDH. A foam plug or a titanium clip is used and the trachea can be unplugged using Ex Utero Intrapartum Tracheoplasty (EXIT) at birth. Since hysterotomy causes premature labour, a video-fetoscopic intrauterine technique of tracheal occlusion called Fetendo-PLUG was developed. Compared to those who receive standard postnatal care or fetal tracheal occlusion via open hysterotomy, patients who undergo Fetendo-PLUG are reported to have a higher survival rate of 75% and fewer fetal and maternal complications. A recent refinement is to use a detachable balloon for intratracheal occlusion through a single 5 mm port under real-time ultrasound guidance. Without the need for neck dissection, injury to the recurrent laryngeal nerves and trachea and vocal cord paresis can be minimized. The result of this form of treatment for CDH is promising, but further refinement of fetal instrumentation and development of effective tocolytic drugs are still required.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shalliker, R. Andrew; Guiochon, Georges A
Understanding the nature of viscosity contrast induced flow instabilities is an important aspect in the design of two-dimensional HPLC separations. When the viscosity contrast between the sample plug and the mobile phase is sufficiently large, the phenomenon known as viscous fingering can be induced. Viscous fingering is a flow instability phenomenon that occurs at the interface between two fluids with different viscosities. In liquid chromatography, viscous fingering results in the solute band undergoing a change in form as it enters into the chromatography column. Moreover, even in the absence of viscous fingering, band shapes change shape at low viscosity contrasts.more » These changes can result in a noticeable change in separation performance, with the result depending on whether the solvent pushing the solute plug has a higher or lower viscosity than the solute plug. These viscosity induced changes become more important as the solute injection volume increases and hence understanding the process becomes critical in the implementation of multidimensional HPLC techniques, since in these techniques the sample injection plug into the second dimension is an order of magnitude greater than in one-dimensional HPLC. This review article assesses the current understanding of the viscosity contrast induced processes as they relate to liquid chromatographic separation behaviour.« less
Friesen, Christopher R; Powers, Donald R; Copenhaver, Paige E; Mason, Robert T
2015-05-01
The non-sperm components of an ejaculate, such as copulatory plugs, can be essential to male reproductive success. But the costs of these ejaculate components are often considered trivial. In polyandrous species, males are predicted to increase energy allocation to the production of non-sperm components, but this allocation is often condition dependent and the energetic costs of their production have never been quantified. Red-sided garter snakes (Thamnophis sirtalis parietalis) are an excellent model with which to quantify the energetic costs of non-sperm components of the ejaculate as they exhibit a dissociated reproductive pattern in which sperm production is temporally disjunct from copulatory plug production, mating and plug deposition. We estimated the daily energy expenditure and resting metabolic rate of males after courtship and mating, and used bomb calorimetry to estimate the energy content of copulatory plugs. We found that both daily energy expenditure and resting metabolic rate were significantly higher in small mating males than in courting males, and a single copulatory plug without sperm constitutes 5-18% of daily energy expenditure. To our knowledge, this is the first study to quantify the energetic expense of size-dependent ejaculate strategies in any species. © 2015. Published by The Company of Biologists Ltd.
49 CFR 179.300-17 - Tests of pressure relief devices.
Code of Federal Regulations, 2010 CFR
2010-10-01
... FOR TANK CARS Specifications for Multi-Unit Tank Car Tanks (Classes DOT-106A and 110AW) § 179.300-17... fusible plug type, a sample of the plug used shall function at the temperatures prescribed in § 179.300-15...
Gohel, Mukesh C; Sumitra G, Manhapra
2002-02-19
The objective of the present study was to obtain programmed drug delivery from hard gelatin capsules containing a hydrophilic plug (HPMC or guar gum). The significance of factors such as type of plug (powder or tablet), plug thickness and the formulation of fill material on the release pattern of diltiazem HCl, a model drug, was investigated. The body portion of the hard gelatin capsules was cross-linked by the combined effect of formaldehyde and heat treatment. A linear relationship was observed between weight of HPMC K15M and log % drug released at 4 h from the capsules containing the plug in powder form. In order to accelerate the drug release after a lag time of 4 h, addition of an effervescent blend, NaHCO(3) and citric acid, in the capsules was found to be essential. The plugs of HPMC in tablet form, with or without a water soluble adjuvant (NaCl or lactose) were used for obtaining immediate drug release after the lag time. Sodium chloride did not cause significant influence on drug release whereas lactose favourably affected the drug release. The capsules containing HPMC K15M tablet plug (200 mg) and 35 mg effervescent blend in body portion of the capsule met the selection criteria of less than 10% drug release in 4 h and immediate drug release thereafter. It is further shown that the drug release was also dependant on the type of swellable hydrophilic agent (HPMC or guar gum) and molecular weight of HPMC (K15M or 20 cPs). The results reveal that programmed drug delivery can be obtained from hard gelatin capsules by systemic formulation approach.
Viscous plugging can enhance and modulate explosivity of strombolian eruptions
NASA Astrophysics Data System (ADS)
Del Bello, E.; Lane, S. J.; James, M. R.; Llewellin, E. W.; Taddeucci, J.; Scarlato, P.; Capponi, A.
2015-08-01
Strombolian activity is common in low-viscosity volcanism. It is characterised by quasi-periodic, short-lived explosions, which, whilst typically weak, may vary greatly in magnitude. The current paradigm for a strombolian volcanic eruption postulates a large gas bubble (slug) bursting explosively after ascending a conduit filled with low-viscosity magma. However, recent studies of pyroclast textures suggest the formation of a region of cooler, degassed, more-viscous magma at the top of the conduit is a common feature of strombolian eruptions. Following the hypothesis that such a rheological impedance could act as a 'viscous plug', which modifies and complicates gas escape processes, we conduct the first experimental investigation of this scenario. We find that: 1) the presence of a viscous plug enhances slug burst vigour; 2) experiments that include a viscous plug reproduce, and offer an explanation for, key phenomena observed in natural strombolian eruptions; 3) the presence and extent of the plug must be considered for the interpretation of infrasonic measurements of strombolian eruptions. Our scaled analogue experiments show that, as the gas slug expands on ascent, it forces the underlying low-viscosity liquid into the plug, creating a low-viscosity channel within a high-viscosity annulus. The slug's diameter and ascent rate change as it enters the channel, generating instabilities and increasing slug overpressure. When the slug reaches the surface, a more energetic burst process is observed than would be the case for a slug rising through the low-viscosity liquid alone. Fluid-dynamic instabilities cause low and high viscosity magma analogues to intermingle, and cause the burst to become pulsatory. The observed phenomena are reproduced by numerical fluid dynamic simulations at the volcanic scale, and provide a plausible explanation for pulsations, and the ejection of mingled pyroclasts, observed at Stromboli and elsewhere.
Osmundson, B.C.; May, T.W.; Osmundson, D.B.
2000-01-01
A Department of the Interior (DOI) irrigation drainwater study of the Uncompahgre Project area and the Grand Valley in western Colorado revealed high selenium concentrations in water, sediment, and biota samples. The lower Gunnison River and the Colorado River in the study area are designated critical habitat for the endangered Colorado pikeminnow (Ptychocheilus lucius) and razorback sucker (Xyrauchen texanus). Because of the endangered status of these fish, sacrificing individuals for tissue residue analysis has been avoided; consequently, little information existed regarding selenium tissue residues. In 1994, muscle plugs were collected from a total of 39 Colorado pikeminnow captured at various Colorado River sites in the Grand Valley for selenium residue analysis. The muscle plugs collected from 16 Colorado pikeminnow captured at Walter Walker State Wildlife Area (WWSWA) contained a mean selenium concentration of 17 ??g/g dry weight, which was over twice the recommended toxic threshold guideline concentration of 8 ??g/g dry weight in muscle tissue for freshwater fish. Because of elevated selenium concentrations in muscle plugs in 1994, a total of 52 muscle plugs were taken during 1995 from Colorado pikeminnow staging at WWSWA. Eleven of these plugs were from fish previously sampled in 1994. Selenium concentrations in 9 of the 11 recaptured fish were significantly lower in 1995 than in 1994. Reduced selenium in fish may in part be attributed to higher instream flows in 1995 and lower water selenium concentrations in the Colorado River in the Grand Valley. In 1996, muscle plugs were taken from 35 Colorado squawfish captured at WWSWA, and no difference in mean selenium concentrations were detected from those sampled in 1995. Colorado River flows during 1996 were intermediate to those measured in 1994 and 1995.
NASA Astrophysics Data System (ADS)
Trowler, Derik Wesley
The research objective of this study was to develop a sizing method for community energy storage systems with emphasis on preventing distribution transformer overloading due to plug-in electric vehicle charging. The method as developed showed the formulation of a diversified load profile based upon residential load data for several customers on the American Electric Power system. Once a load profile was obtained, plug-in electric vehicle charging scenarios which were based upon expected adoption and charging trends were superimposed on the load profile to show situations where transformers (in particular 25 kVA, 50 kVA, and 100 kVA) would be overloaded during peak hours. Once the total load profiles were derived, the energy and power requirements of community energy storage systems were calculated for a number of scenarios with different combinations of numbers of homes and plug-in electric vehicles. The results were recorded and illustrated into charts so that one could determine the minimum size per application. Other topics that were covered in this thesis were the state of the art and future trends in plug-in electric vehicle and battery chemistry adoption and development. The goal of the literature review was to confirm the already suspected notion that Li-ion batteries are best suited and soon to be most cost-effective solution for applications requiring small, efficient, reliable, and light-weight battery systems such as plug-in electric vehicles and community energy storage systems. This thesis also includes a chapter showing system modeling in MATLAB/SimulinkRTM. All in all, this thesis covers a wide variety of considerations involved in the designing and deploying of community energy storage systems intended to mitigate the effects of distribution transformer overloading.
Instability-induced ordering, universal unfolding and the role of gravity in granular Couette flow
NASA Astrophysics Data System (ADS)
Alam, Meheboob; Arakeri, V. H.; Nott, P. R.; Goddard, J. D.; Herrmann, H. J.
2005-01-01
Linear stability theory and bifurcation analysis are used to investigate the role of gravity in shear-band formation in granular Couette flow, considering a kinetic-theory rheological model. We show that the only possible state, at low shear rates, corresponds to a "plug" near the bottom wall, in which the particles are densely packed and the shear rate is close to zero, and a uniformly sheared dilute region above it. The origin of such plugged states is shown to be tied to the spontaneous symmetry-breaking instabilities of the gravity-free uniform shear flow, leading to the formation of ordered bands of alternating dilute and dense regions in the transverse direction, via an infinite hierarchy of pitchfork bifurcations. Gravity plays the role of an "imperfection", thus destroying the "perfect" bifurcation structure of uniform shear. The present bifurcation problem admits universal unfolding of pitchfork bifurcations which subsequently leads to the formation of a sequence of a countably infinite number of "isolas", with the solution structures being a modulated version of their gravity-free counterpart. While the solution with a plug near the bottom wall looks remarkably similar to the shear-banding phenomenon in dense slow granular Couette flows, a "floating" plug near the top wall is also a solution of these equations at high shear rates. A two-dimensional linear stability analysis suggests that these floating plugged states are unstable to long-wave travelling disturbances.The unique solution having a bottom plug can also be unstable to long waves, but remains stable at sufficiently low shear rates. The implications and realizability of the present results are discussed in the light of shear-cell experiments under "microgravity" conditions.
On the Limitations of Breakthrough Curve Analysis in Fixed-Bed Adsorption
NASA Technical Reports Server (NTRS)
Knox, James C.; Ebner, Armin D.; LeVan, M. Douglas; Coker, Robert F.; Ritter, James A.
2016-01-01
This work examined in detail the a priori prediction of the axial dispersion coefficient from available correlations versus obtaining it and also mass transfer information from experimental breakthrough data and the consequences that may arise when doing so based on using a 1-D axially dispersed plug flow model and its associated Danckwerts outlet boundary condition. These consequences mainly included determining the potential for erroneous extraction of the axial dispersion coefficient and/or the LDF mass transfer coefficient from experimental data, especially when non-plug flow conditions prevailed in the bed. Two adsorbent/adsorbate cases were considered, i.e., carbon dioxide and water vapor in zeolite 5A, because they both experimentally exhibited significant non-plug flow behavior, and the water-zeolite 5A system exhibited unusual concentration front sharpening that destroyed the expected constant pattern behavior (CPB) when modeled with the 1-D axially dispersed plug flow model. Overall, this work showed that it was possible to extract accurate mass transfer and dispersion information from experimental breakthrough curves using a 1-D axial dispersed plug flow model when they were measured both inside and outside the bed. To ensure the extracted information was accurate, the inside the bed breakthrough curves and their derivatives from the model were plotted to confirm whether or not the adsorbate/adsorbent system was exhibiting CPB or any concentration front sharpening near the bed exit. Even when concentration front sharpening was occurring with the water-zeolite 5A system, it was still possible to use the experimental inside and outside the bed breakthrough curves to extract fundamental mass transfer and dispersion information from the 1-D axial dispersed plug flow model based on the systematic methodology developed in this work.
Baruteau, Alban-Elouen; Lambert, Virginie; Riou, Jean-Yves; Angel, Claude-Yves; Belli, Emre; Petit, Jérôme
2015-01-01
Closure of tubular patent ductus arteriosus remains a challenging procedure. Anecdotal use of Amplatzer Vascular Plug IV for tubular ductus closure has been reported but feasibility and safety in a consecutive patients' series remain unknown. We performed a monocenter prospective study at the Marie Lannelongue Hospital in Paris, France. From 2009 to 2014, a total of 47 patients (39 infants, 3 children, and 5 adults) underwent ductus closure with the Plug IV. Ductus morphology was a type E in 34 (72.3%) patients and a type C in 13 (27.7%) patients. Ductus closure occurred in 39 (83.0%) infants at a median age of seven months (range: 3-23 months) and a median weight of 6.9 kg (range: 4.1-17.0 kg). A past history of prematurity and very low birth weight was found in 33 (70.2%) of them. Twelve (25.5%) patients had pulmonary hypertension. Mean Plug IV diameter was 1.9 ± 0.1 mm larger than the mean maximal ductus diameter. Early complete closure of the ductus was obtained in all patients. Early migration of an undersized Plug IV occurred in one (2.1%) patient and was suitable for percutaneous device retrieval. After a mean follow-up of 3.4 ± 1.4 years, all patients are alive and asymptomatic, no late complication occurred. Transcatheter closure of tubular ductus with the Amplatzer Vascular Plug IV can be safe and effective, with a 100% early occlusion rate. This device, suitable for a 4F sheath, is a new alternative for tubular ductus closure in low-body-weight infants. © The Author(s) 2014.
Osmundson, B C; May, T W; Osmundson, D B
2000-05-01
A Department of the Interior (DOI) irrigation drainwater study of the Uncompahgre Project area and the Grand Valley in western Colorado revealed high selenium concentrations in water, sediment, and biota samples. The lower Gunnison River and the Colorado River in the study area are designated critical habitat for the endangered Colorado pikeminnow (Ptychocheilus lucius) and razorback sucker (Xyrauchen texanus). Because of the endangered status of these fish, sacrificing individuals for tissue residue analysis has been avoided; consequently, little information existed regarding selenium tissue residues. In 1994, muscle plugs were collected from a total of 39 Colorado pikeminnow captured at various Colorado River sites in the Grand Valley for selenium residue analysis. The muscle plugs collected from 16 Colorado pikeminnow captured at Walter Walker State Wildlife Area (WWSWA) contained a mean selenium concentration of 17 microg/g dry weight, which was over twice the recommended toxic threshold guideline concentration of 8 microg/g dry weight in muscle tissue for freshwater fish. Because of elevated selenium concentrations in muscle plugs in 1994, a total of 52 muscle plugs were taken during 1995 from Colorado pikeminnow staging at WWSWA. Eleven of these plugs were from fish previously sampled in 1994. Selenium concentrations in 9 of the 11 recaptured fish were significantly lower in 1995 than in 1994. Reduced selenium in fish may in part be attributed to higher instream flows in 1995 and lower water selenium concentrations in the Colorado River in the Grand Valley. In 1996, muscle plugs were taken from 35 Colorado squawfish captured at WWSWA, and no difference in mean selenium concentrations were detected from those sampled in 1995. Colorado River flows during 1996 were intermediate to those measured in 1994 and 1995.
Plug-In Electric Vehicle Handbook for Fleet Managers (Brochure)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
2012-04-01
Plug-in electric vehicles (PEVs) are entering the automobile market and are viable alternatives to conventional vehicles. This guide for fleet managers describes the basics of PEV technology, PEV benefits for fleets, how to select the right PEV, charging a PEV, and PEV maintenance.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Smart, John Galloway; Salisbury, Shawn Douglas
2015-07-01
This report summarizes key findings in two national plug-in electric vehicle charging infrastructure demonstrations: The EV Project and ChargePoint America. It will be published to the INL/AVTA website for the general public.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Melaina, Marc; Helwig, Michael
The California Statewide Plug-In Electric Vehicle Infrastructure Assessment conveys to interested parties the Energy Commission’s conclusions, recommendations, and intentions with respect to plug-in electric vehicle (PEV) infrastructure development. There are several relatively low-risk and high-priority electric vehicle supply equipment (EVSE) deployment options that will encourage PEV sales and
40 CFR 146.92 - Injection well plugging.
Code of Federal Regulations, 2011 CFR
2011-07-01
... operator must flush each Class VI injection well with a buffer fluid, determine bottomhole reservoir... for determining bottomhole reservoir pressure; (2) Appropriate testing methods to ensure external... accurate by the owner or operator and by the person who performed the plugging operation (if other than the...
NASA Astrophysics Data System (ADS)
Bolton, Richard W.; Dewey, Allen; Horstmann, Paul W.; Laurentiev, John
1997-01-01
This paper examines the role virtual enterprises will have in supporting future business engagements and resulting technology requirements. Two representative end-user scenarios are proposed that define the requirements for 'plug-and-play' information infrastructure frameworks and architectures necessary to enable 'virtual enterprises' in US manufacturing industries. The scenarios provide a high- level 'needs analysis' for identifying key technologies, defining a reference architecture, and developing compliant reference implementations. Virtual enterprises are short- term consortia or alliances of companies formed to address fast-changing opportunities. Members of a virtual enterprise carry out their tasks as if they all worked for a single organization under 'one roof', using 'plug-and-play' information infrastructure frameworks and architectures to access and manage all information needed to support the product cycle. 'Plug-and-play' information infrastructure frameworks and architectures are required to enhance collaboration between companies corking together on different aspects of a manufacturing process. This new form of collaborative computing will decrease cycle-time and increase responsiveness to change.
The Mars Development of a Micro-Isolation Valve
NASA Technical Reports Server (NTRS)
Mueller, Juergen; Vargo, Steven; Forgrave, John; Bame, David; Chakraborty, Indrani; Tang, William
1999-01-01
A feasibility investigation for a newly proposed microfabricated, normally-closed isolation valve was initiated. The micro-isolation valve is silicon based and relies on the principle of melting a silicon plug, opening an otherwise sealed flow passage. This valve may thus serve a similar role as a conventional pyrovalve and is intended for use in micropropulsion systems onboard future microspacecraft, having wet masses of no more than 10-20 kg, as well as in larger scale propulsion systems having only low flow rate requirements, such as ion propulsion or Hall thruster systems. Two key feasibility issues - melting of the plug and pressure handling capability - were addressed. Thermal finite element modeling showed that valves with plugs having widths between 10 and 50 gm have power requirements of only 10 . 30 Watts to open over a duration of 0.5 ms or less. Valve chips featuring 5 0 micron plugs were burst pressure tested and reached maximum pressure values o f 2900 psig (19.7 Mpa).
Bubbling and foaming assisted clearing of mucin plugs in microfluidic Y-junctions.
Abdula, Daner; Lerud, Ryan; Rananavare, Shankar
2017-11-07
Microfluidic Y-junctions were used to study mechanical mechanisms involved in pig gastric mucin (PGM) plug removal from within one of two bifurcation branches with 2-phase air and liquid flow. Water control experiments showed moderate plug removal due to shear from vortex formation in the blockage branch and suggest a PGM yield stress of 35Pa, as determined by computational fluid dynamics. Addition of hexadecyltrimethylammonium bromide (CTAB) surfactant improved clearing effectiveness due to bubbling in 1mm diameter channels and foaming in 500μm diameter channels. Plug removal mechanisms have been identified as vortex shear, bubble scouring, and then foam scouring as air flow rate is increased with constant liquid flow. The onset of bubbling and foaming is attributed to a flow regime transition from slug to slug-annular. Flow rates explored for 1mm channels are typically experienced by bronchioles in generations 8 and 9 of lungs. Results have implications on treatment of cystic fibrosis and other lung diseases. Copyright © 2016 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Alexandrov, Dmitri V.; Bashkirtseva, Irina A.; Ryashko, Lev B.
2015-04-01
A non-linear behavior of dynamic model of the magma-plug system under the action of N-shaped friction force and stochastic disturbances is studied. It is shown that the deterministic dynamics essentially depends on the mutual arrangement of an equilibrium point and the friction force branches. Variations of this arrangement imply bifurcations, birth and disappearance of stable limit cycles, changes of the stability of equilibria, system transformations between mono- and bistable regimes. A slope of the right increasing branch of the friction function is responsible for the formation of such regimes. In a bistable zone, the noise generates transitions between small and large amplitude stochastic oscillations. In a monostable zone with single stable equilibrium, a new dynamic phenomenon of noise-induced generation of large amplitude stochastic oscillations in the plug rate and pressure is revealed. A beat-type dynamics of the plug displacement under the influence of stochastic forcing is studied as well.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ramroth, L. A.; Gonder, J. D.; Brooker, A. D.
2013-04-01
The National Renewable Energy Laboratory (NREL) validated diesel-conventional and diesel-hybrid medium-duty parcel delivery vehicle models to evaluate petroleum reductions and cost implications of hybrid and plug-in hybrid diesel variants. The hybrid and plug-in hybrid variants are run on a field data-derived design matrix to analyze the effect of drive cycle, distance, engine downsizing, battery replacements, and battery energy on fuel consumption and lifetime cost. For an array of diesel fuel costs, the battery cost per kilowatt-hour at which the hybridized configuration becomes cost-effective is calculated. This builds on a previous analysis that found the fuel savings from medium duty plug-inmore » hybrids more than offset the vehicles' incremental price under future battery and fuel cost projections, but that they seldom did so under present day cost assumptions in the absence of purchase incentives. The results also highlight the importance of understanding the application's drive cycle specific daily distance and kinetic intensity.« less
Nuclear reactor pressure vessel support system
Sepelak, George R.
1978-01-01
A support system for nuclear reactor pressure vessels which can withstand all possible combinations of stresses caused by a postulated core disrupting accident during reactor operation. The nuclear reactor pressure vessel is provided with a flange around the upper periphery thereof, and the flange includes an annular vertical extension formed integral therewith. A support ring is positioned atop of the support ledge and the flange vertical extension, and is bolted to both members. The plug riser is secured to the flange vertical extension and to the top of a radially outwardly extension of the rotatable plug. This system eliminates one joint through which fluids contained in the vessel could escape by making the fluid flow path through the joint between the flange and the support ring follow the same path through which fluid could escape through the plug risers. In this manner, the sealing means to prohibit the escape of contained fluids through the plug risers can also prohibit the escape of contained fluid through the securing joint.
NASA Astrophysics Data System (ADS)
Mozaffari, Ahmad; Vajedi, Mahyar; Chehresaz, Maryyeh; Azad, Nasser L.
2016-03-01
The urgent need to meet increasingly tight environmental regulations and new fuel economy requirements has motivated system science researchers and automotive engineers to take advantage of emerging computational techniques to further advance hybrid electric vehicle and plug-in hybrid electric vehicle (PHEV) designs. In particular, research has focused on vehicle powertrain system design optimization, to reduce the fuel consumption and total energy cost while improving the vehicle's driving performance. In this work, two different natural optimization machines, namely the synchronous self-learning Pareto strategy and the elitism non-dominated sorting genetic algorithm, are implemented for component sizing of a specific power-split PHEV platform with a Toyota plug-in Prius as the baseline vehicle. To do this, a high-fidelity model of the Toyota plug-in Prius is employed for the numerical experiments using the Autonomie simulation software. Based on the simulation results, it is demonstrated that Pareto-based algorithms can successfully optimize the design parameters of the vehicle powertrain.
Folding-paper-based preconcentrator for low dispersion of preconcentration plug
NASA Astrophysics Data System (ADS)
Lee, Kyungjae; Yoo, Yong Kyoung; Han, Sung Il; Lee, Junwoo; Lee, Dohwan; Kim, Cheonjung; Lee, Jeong Hoon
2017-12-01
Ion concentration polarization (ICP) has been widely studied for collecting target analytes as it is a powerful preconcentrator method employed for charged molecules. Although the method is quite robust, simple, cheap, and yields a high preconcentration factor, a major hurdle to be addressed is extracting the preconcentrated samples without dispersing the plug. This study investigates a 3D folding-paper-based ICP preconcentrator for preconcentrated plug extraction without the dispersion effect. The ICP preconcentrator is printed on a cellulose paper with pre-patterned hydrophobic wax. To extract and isolate the preconcentration plug with minimal dispersion, a 3D pop-up structure is fabricated via water drain, and a preconcentration factor of 300-fold for 10 min is achieved. By optimizing factors such as the electric field, water drain, and sample volume, the technique was enhanced by facilitating sample preconcentration and isolation, thereby providing the possibility for extensive applications in analytical devices such as lateral flow assays and FTAR cards.
NASA Technical Reports Server (NTRS)
Andrea-Liner, Kathleen E.; Au, Brion J.; Fisher, Blake R.; Rodbumrung, Watchara; Hamic, Jeffrey C.; Smith, Kary; Beadle, David S.
2012-01-01
The role of PLUTO (Plug-in Port UTilization Officer) and the growth of the International Space Station (ISS) have exceeded the capabilities of the current tool PiP (Plug-in Plan). Its users (crew and flight controllers) have expressed an interest in a new, easy-to-use tool with a higher level of interactivity and functionality that is not bound by the limitations of Excel. The PiP Tool assists crewmembers and ground controllers in making real-time decisions concerning the safety and compatibility of hardware plugged into the UOPs (Utility Outlet Panels) onboard the ISS. The PiP Tool also provides a reference to the current configuration of the hardware plugged in to the UOPs, and enables the PLUTO and crew to test Plug-in locations for constraint violations (such as cable connector mismatches or amp limit violations), to see the amps and volts for an end item, to see whether or not the end item uses 1553 data, and the cable length between the outlet and the end item. As new equipment is flown or returned, the database can be updated appropriately as needed. The current tool is a macroheavy Excel spreadsheet with its own database and reporting functionality. The new tool captures the capabilities of the original tool, ports them to new software, defines a new dataset, and compensates for ever-growing unique constraints associated with the Plug-in Plan. New constraints were designed into the tool, and updates to existing constraints were added to provide more flexibility and customizability. In addition, there is an option to associate a "Flag" with each device that will let the user know there is a unique constraint associated with it when they use it. This helps improve the safety and efficiency of real-time calls by limiting the amount of "corporate knowledge" overhead that has to be trained and learned through use. The tool helps save time by automating previous manual processes, such as calculating connector types and deciding which cables are required and in what order.
The effect of gravity on liquid plug propagation in a two-dimensional channel
NASA Astrophysics Data System (ADS)
Suresh, V.; Grotberg, J. B.
2005-03-01
The effect of plug propagation speed and gravity on the quasisteady motion of a liquid plug in a two-dimensional liquid-lined channel oriented at an angle α with respect to gravity is studied. The problem is motivated by the transport of liquid plugs instilled into pulmonary airways in medical treatments such as surfactant replacement therapy, drug delivery, and liquid ventilation. The capillary number Ca is assumed to be small, while the Bond number Bo is arbitrary. Using matched asymptotic expansions and lubrication theory, expressions are obtained for the thickness of the trailing films left behind by the plug and the pressure drop across it as functions of Ca, Bo, α and the thickness of the precursor films. When the Bond number is small it is found that the trailing film thickness and the flow contribution to the pressure drop scale as Ca2/3 at leading order with coefficients that depend on Bo and α. The first correction to the film thickness is found to occur at O(Ca) compared to O(Ca4/3) in the Bo=0 case. Asymmetry in the liquid distribution is quantified by calculating the ratio of liquid volumes above and below the centerline of the channel, VR ˙. VR=1 at Bo=0, indicating a symmetric distribution, and decreases with Bo and Ca, but increases with the plug length Lp. The decrease of VR with Ca suggests that higher propagation speeds in small airways may result in less homogenous liquid distribution, which is in contrast to the expected effect in large airways. For given values of the other parameters, a maximum capillary number Cac is identified above which the plug will eventually rupture. When the Bond number becomes equal to an orientation-dependent critical value Boc, it is found that the scaling of the film thickness and pressure drop change to Ca1/2 and Ca1/6, respectively. It is shown that this scaling is valid for small increments of the Bond number over its critical value, Bo=Boc+BCa1/6, but for higher Bond numbers the asymptotic approach breaks down.
Mayr, Hermann O; Hube, Robert; Bernstein, Anke; Seibt, Alexander B; Hein, Werner; von Eisenhart-Rothe, Ruediger
2007-06-01
The goal of this study was to test fixation properties of microporous pure beta-tricalcium phosphate (TCP) plugs (porosity 40%) for press-fit fixation of the ACL graft using patellar tendons with and without bone blocks. We set out to establish whether it is possible, in this way, to obtain results comparable with those of interference screw fixation of bone-tendon-bone (BTB) grafts in terms of cyclic loading and load-to-failure. In a bovine model 30 ACL grafts were fixed in tibial drill holes, divided into three groups: 10 BTB grafts fixed with TCP press-fit plugs (7x25 mm), 10 pure patellar tendon grafts with TCP press-fit plugs (7x25 mm), and 10 BTB grafts with metal interference screws (7x25 mm). All grafts were tested by cyclic loading (50-200 N) and loaded until failure in a tensiometer. Under cyclic loading one interference screw fixation failed. None of the TCP plug fixations failed. After 1500 cycles the displacement of the graft in the drill hole for BTB fixed with screws was 3.6+/-7.8 mm, for BTB/TCP plugs 1.6+/-3.4 mm, and for the pure tendon/TCP grafts 1.4+/-0.4 mm. Regarding cyclic loading the pure tendon/TCP system was significantly superior to BTB (p=0.007). The load-to-failure for the BTB/interference screw group was 908+/-539 N with a stiffness of 94+/-36 N/mm, 936+/-245 N for the BTB/TCP cylinder group with a stiffness of 98+/-12 N/mm, and 673+/-159 N for the pure tendon/TCP group with a stiffness of 117+/-9 N/mm. In terms of pull-out load the BTB/TCP system was significantly better than the pure tendon/TCP group (p=0.011). However, pure tendon/TCP grafts achieved significantly greater stiffness (p=0.002) than the BTB system. Press-fit fixation with microporous pure beta-TCP plugs of BTB grafts or patellar tendon grafts without bone blocks for ACL reconstruction leads to primary stability comparable with that achieved by fixation with metal interference screws in case of BTB grafts.
Equilibrium geochemical modeling of a seasonal thermal energy storage aquifer field test
NASA Technical Reports Server (NTRS)
Stottlemyre, J. S.
1980-01-01
A geochemical mathematical modeling study designed to investigate the well plugging problems encountered at the Auburn University experimental field tests is summarized. The results, primarily of qualitative interest, include: (1) loss of injectivity was probably due to a combination of native particulate plugging and clay swelling and dispersion; (2) fluid-fluid incompatibilities, hydrothermal reactions, and oxidation reactions were of insignificant magnitude or too slow to have contributed markedly to the plugging; and (3) the potential for and contributions from temperature-induced dissolved gas solubility reductions, capillary boundary layer viscosity increases, and microstructural deformation cannot be deconvolved from the available data.
Modelling of plug and play interface for energy router based on IEC61850
NASA Astrophysics Data System (ADS)
Shi, Y. F.; Yang, F.; Gan, L.; He, H. L.
2017-11-01
Under the background of the “Internet Plus”, as the energy internet infrastructure equipment, energy router will be widely developed. The IEC61850 standard is the only universal standard in the field of power system automation which realizes the standardization of engineering operation of intelligent substation. To eliminate the lack of International unified standard for communication of energy router, this paper proposes to apply IEC61850 to plug and play interface and establishes the plug and play interface information model and information transfer services. This paper provides a research approach for the establishment of energy router communication standards, and promotes the development of energy router.
Distributed ignition method and apparatus for a combustion engine
Willi, Martin L.; Bailey, Brett M.; Fiveland, Scott B.; Gong, Weidong
2006-03-07
A method and apparatus for operating an internal combustion engine is provided. The method comprises the steps of introducing a primary fuel into a main combustion chamber of the engine, introducing a pilot fuel into the main combustion chamber of the engine, determining an operating load of the engine, determining a desired spark plug ignition timing based on the engine operating load, and igniting the primary fuel and pilot fuel with a spark plug at the desired spark plug ignition timing. The method is characterized in that the octane number of the pilot fuel is lower than the octane number of the primary fuel.
NASA Technical Reports Server (NTRS)
Kim, S.; Trinh, H. P.
1992-01-01
The paper discusses the performance effects resulting from plugged LOX posts of the Space Shuttle Main Engine Injector. The simulation was performed with the REFLEQS 2-D code. Analysis was performed axisymmetrically and injector surface was divided into several regions to account for the mixture ratio variation on the injector surface. The reduction of vaccum specific impulse was approximately 0.01 second per plugged LOX post. This reduction is an order of magnitude higher than the result of Space Shuttle flight reconstruction data. It is presumed that this overprediction is due to the axisymmetric simulation that smears local effects.
NASA Technical Reports Server (NTRS)
Burley, R. R.; Head, V. L.
1974-01-01
Because of the relatively high takeoff speeds of supersonic transport aircraft, it is important to know if the flight velocity affects the noise level of suppressor nozzles. To investigate this, a modified F-106B aircraft was used to conduct a series of flyover and static tests on a 48-tube suppressor installed on an uncooled plug nozzle. Comparison of flyover and static spectra indicated that flight velocity had little effect on the noise suppression of the 48-tube suppressor configuration. However, flight velocity adversely affected noise suppression of the 48-tube suppressor with an acoustic shroud and plug installed.
Parallax visualization of full motion video using the Pursuer GUI
NASA Astrophysics Data System (ADS)
Mayhew, Christopher A.; Forgues, Mark B.
2014-06-01
In 2013, the Authors reported to the SPIE on the Phase 1 development of a Parallax Visualization (PV) plug-in toolset for Wide Area Motion Imaging (WAMI) data using the Pursuer Graphical User Interface (GUI).1 In addition to the ability to PV WAMI data, the Phase 1 plug-in toolset also featured a limited ability to visualize Full Motion video (FMV) data. The ability to visualize both WAMI and FMV data is highly advantageous capability for an Electric Light Table (ELT) toolset. This paper reports on the Phase 2 development and addition of a full featured FMV capability to the Pursuer WAMI PV Plug-in.
Study of Plasma Behavior during ECRH Injection in the GAMMA 10 SMBI Experiments
NASA Astrophysics Data System (ADS)
Maidul Islam, Md.; Nakashima, Yousuke; Kobayashi, Shinji; Nishino, Nobuhiro; Ichimura, Kazuya; Iijima, Takaaki; Shahinul Islam, Md.; Yokodo, Takayuki; Lee, Guanyi; Yoshimoto, Tsubasa; Yamashita, Sotaro; Yoshikawa, Masayuki; Kohagura, Junko; Hirata, Mafumi; Minami, Ryutaro; Kariya, Tsuyoshi; Ikezoe, Ryuya; Ichimura, Makoto; Sakamoto, Mizuki; Imai, Tsuyoshi
2018-01-01
Establishment of fueling system is one of the critical issues for the future fusion reactors. Fueling experiment supersonic molecular beam injection (SMBI) have been carried out in the central-cell of GAMMA 10. In GAMMA 10, electron cyclotron resonance heating (ECRH) is used at plug/barrier-cells for the formation of the axial confining potential. Recently, ECRH was applied during SMBI to plug the loss particles and increased the plasma density in the central-cell compared to without ECRH. This result suggests that the particles are confined during SMBI due to the injection of ECRH at plug/barrier-cells in GAMMA 10.
Comparison of an Inductance In-Line Oil Debris Sensor and Magnetic Plug Oil Debris Sensor
NASA Technical Reports Server (NTRS)
Dempsey, Paula J.; Tuck, Roger; Showalter, Stephen
2012-01-01
The objective of this research was to compare the performance of an inductance in-line oil debris sensor and magnetic plug oil debris sensor when detecting transmission component health in the same system under the same operating conditions. Both sensors were installed in series in the NASA Glenn Spiral Bevel Gear Fatigue Rig during tests performed on 5 gear sets (pinion/gear) when different levels of damage occurred on the gear teeth. Results of this analysis found both the inductance in-line oil debris sensor and magnetic plug oil debris sensor have benefits and limitations when detecting gearbox component damage.
Clean Cities Plug-In Electric Vehicle Handbook for Fleet Managers
DOE Office of Scientific and Technical Information (OSTI.GOV)
None
2012-04-01
Plug-in electric vehicles (PEVs) are entering the automobile market and are viable alternatives to conventional vehicles. This guide for fleet managers describes the basics of PEV technology, PEV benefits for fleets, how to select the right PEV, charging a PEV, and PEV maintenance.
Code of Federal Regulations, 2013 CFR
2013-07-01
...) IEC 309-1—Plugs, Socket-Outlets and Couplers for Industrial Purposes: Part 1, General Requirements, 1979, IBR approved for § 154.812. (2) IEC 309-2—Plugs, Socket-Outlets and Couplers for Industrial...
Predicting the market potential of plug-in electric vehicles using multiday GPS data.
DOT National Transportation Integrated Search
2011-12-01
"Detailed GPS data for a years worth of travel by 255 households from the Seattle area were used to : investigate how plug-in electric vehicle types may affect adoption rates and use levels. The results suggest : that a battery-electric vehicle (B...
DOT National Transportation Integrated Search
2015-12-01
Plug-in hybrid electric vehicles (PHEV) are likely to increase in popularity in the near future. However, the : environmental benefits of PHEVs involve tradeoffs between the benefits of reduced tailpipe emissions : against the drawbacks of increased ...
DOE Office of Scientific and Technical Information (OSTI.GOV)
None
Electric-drive vehicles use electricity as their primary fuel or to improve the efficiency of conventional vehicle designs. These vehicles can be divided into three categories: Hybrid electric vehicles (HEVs), Plug-in hybrid electric vehicles (PHEVs), All-electric vehicles (EVs). Together, PHEVs and EVs can also be referred to as plug-in electric vehicles (PEVs).
76 FR 72028 - Buy America Waiver Notification
Federal Register 2010, 2011, 2012, 2013, 2014
2011-11-21
...-battery electric vehicles, 12 plug-in hybrid vehicles, and 5 neighborhood electric vehicles in San... a partial Buy America waiver is appropriate for the purchase of 12 all-battery electric vehicles, 12 plug-in hybrid vehicles, and 5 neighborhood electric vehicles in San Francisco County, California. In...
29 CFR 1910.334 - Use of equipment.
Code of Federal Regulations, 2010 CFR
2010-07-01
.... (a) Portable electric equipment. This paragraph applies to the use of cord- and plug-connected... in a manner which will not cause damage. Flexible electric cords connected to equipment may not be...) Portable cord- and plug-connected equipment and flexible cord sets (extension cords) shall be visually...
77 FR 64379 - Proposed Collection; Comment Request for Notice 2009-58
Federal Register 2010, 2011, 2012, 2013, 2014
2012-10-19
... Notice 2009-58, Manufacturers' Certification of Specified Plug-in Electric Vehicles. DATES: Written... Electric Vehicles. OMB Number: 1545-2150. Notice Number: Notice 2009-58. Abstract: The American Recovery... certain new specified plug-in electric drive vehicles. This notice provides procedures for a vehicle...
Gender differences in real-world hearing protector attenuation.
Abel, S M; Alberti, P W; Rokas, D
1988-04-01
This research investigated the possibility of differences in real-world attenuation attributable to gender. A total of 160 subjects, 80 males and 80 females, under the age of 45 years, and with normal hearing, were tested. Subjects were assigned to four hearing protector categories with the restriction that there were 20 males and 20 females in each group. The devices chosen for study were the E-A-R expandable foam plug, the Willson Sound Silencer premolded vinyl plug with double flange, the Bilsom Soft polyethylene encapsulated glass fiber plug, and the MSA Ear Defender (V-51R) premolded vinyl plug with single flange. Binaural headphone detection thresholds were measured in quiet with the open ear, and subsequently with protectors fitted binaurally for one-third octave noise bands centered at 250, 500, 1000, 3150 and 6300 Hz. The results indicated that attenuation scores achieved by females were less than those observed for males when the device was sold in only one size. Apart from the question of adequate sizing, for two of the insert protectors studied, mean achieved attenuation fell short of the manufacturer's specifications by as much as 18 dB, for particular frequencies tested. The relatively wide variation in scores observed for all four protectors in spite of experimenter-fit could not be accounted for by differences in either hearing threshold across subjects or by size of plug fit, for those devices available in several sizes.
Experimental Study on Environment Friendly Tap Hole Clay for Blast Furnace
NASA Astrophysics Data System (ADS)
Siva kumar, R.; Mohammed, Raffi; Srinivasa Rao, K.
2018-03-01
Blast furnace (BF) is the best possible route of iron production available. Blast furnace is a high pressure vessel where iron ore is melted and liquid iron is produced. The liquid iron is tapped through the hole in Blast Furnace called tap hole. The tapped liquid metal flowing through the tap hole is plugged using a clay called tap hole clay. Tap hole clay (THC) is a unshaped refractory used to plug the tap hole. The tap hole clay extruded through the tap hole using a gun. The tap hole clay is designed to expand and plug the tap hole. The tap hole filled with clay is drilled using drill bit and the hole made through the tap hole to tap the liquid metal accumulated inside the furnace. The number of plugging and drilling varies depending on the volume of the furnace. The tap hole clay need to have certain properties to avoid problems during plugging and drilling. In the present paper tap hole clay properties in industrial use was tested and studied. The problems were identified related to tap hole clay manufacturing. Experiments were conducted in lab scale to solve the identified problems. The present composition was modified with experimental results. The properties of the modified tap hole clay were found suitable and useful for blast furnace operation with lab scale experimental results.
Luk, Jason M; Saville, Bradley A; MacLean, Heather L
2015-04-21
This paper aims to comprehensively distinguish among the merits of different vehicles using a common primary energy source. In this study, we consider compressed natural gas (CNG) use directly in conventional vehicles (CV) and hybrid electric vehicles (HEV), and natural gas-derived electricity (NG-e) use in plug-in battery electric vehicles (BEV). This study evaluates the incremental life cycle air emissions (climate change and human health) impacts and life cycle ownership costs of non-plug-in (CV and HEV) and plug-in light-duty vehicles. Replacing a gasoline CV with a CNG CV, or a CNG CV with a CNG HEV, can provide life cycle air emissions impact benefits without increasing ownership costs; however, the NG-e BEV will likely increase costs (90% confidence interval: $1000 to $31 000 incremental cost per vehicle lifetime). Furthermore, eliminating HEV tailpipe emissions via plug-in vehicles has an insignificant incremental benefit, due to high uncertainties, with emissions cost benefits between -$1000 and $2000. Vehicle criteria air contaminants are a relatively minor contributor to life cycle air emissions impacts because of strict vehicle emissions standards. Therefore, policies should focus on adoption of plug-in vehicles in nonattainment regions, because CNG vehicles are likely more cost-effective at providing overall life cycle air emissions impact benefits.
NASA Astrophysics Data System (ADS)
Ezoe, Yuichiro; DiPirro, Michael; Fujimoto, Ryuichi; Ishikawa, Kumi; Ishisaki, Yoshitaka; Kanao, Kenichi; Kimball, Mark; Mitsuda, Kazuhisa; Mitsuishi, Ikuyuki; Murakami, Masahide; Noda, Hirofumi; Ohashi, Takaya; Okamoto, Atsushi; Satoh, Yohichi; Sato, Kosuke; Shirron, Peter; Tsunematsu, Shoji; Yamaguchi, Hiroya; Yoshida, Seiji
2018-01-01
When using superfluid helium in low-gravity environments, porous plug phase separators are commonly used to vent boil-off gas while confining the bulk liquid to the tank. Invariably, there is a flow of superfluid film from the perimeter of the porous plug down the vent line. For the soft x-ray spectrometer onboard ASTRO-H (Hitomi), its approximately 30-liter helium supply has a lifetime requirement of more than 3 years. A nominal vent rate is estimated as ˜30 μg/s, equivalent to ˜0.7 mW heat load. It is, therefore, critical to suppress any film flow whose evaporation would not provide direct cooling of the remaining liquid helium. That is, the porous plug vent system must be designed to both minimize film flow and to ensure maximum extraction of latent heat from the film. The design goal for Hitomi is to reduce the film flow losses to <2 μg/s, corresponding to a loss of cooling capacity of <40 μW. The design adopts the same general design as implemented for Astro-E and E2, using a vent system composed of a porous plug, combined with an orifice, a heat exchanger, and knife-edge devices. Design, on-ground testing results, and in-orbit performance are described.
Recovery Act. Advanced Load Identification and Management for Buildings
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yang, Yi; Casey, Patrick; Du, Liang
2014-02-12
In response to the U.S. Department of Energy (DoE)’s goal of achieving market ready, net-zero energy residential and commercial buildings by 2020 and 2025, Eaton partnered with the Department of Energy’s National Renewable Energy Laboratory (NREL) and Georgia Institute of Technology to develop an intelligent load identification and management technology enabled by a novel “smart power strip” to provide critical intelligence and information to improve the capability and functionality of building load analysis and building power management systems. Buildings account for 41% of the energy consumption in the United States, significantly more than either transportation or industrial. Within the buildingmore » sector, plug loads account for a significant portion of energy consumption. Plug load consumes 15-20% of building energy on average. As building managers implement aggressive energy conservation measures, the proportion of plug load energy can increase to as much as 50% of building energy leaving plug loads as the largest remaining single source of energy consumption. This project focused on addressing plug-in load control and management to further improve building energy efficiency accomplished through effective load identification. The execution of the project falls into the following three major aspects; An intelligent load modeling, identification and prediction technology was developed to automatically determine the type, energy consumption, power quality, operation status and performance status of plug-in loads, using electric waveforms at a power outlet level. This project demonstrated the effectiveness of the developed technology through a large set of plug-in loads measurements and testing; A novel “Smart Power Strip (SPS) / Receptacle” prototype was developed to act as a vehicle to demonstrate the feasibility of load identification technology as a low-cost, embedded solution; and Market environment for plug-in load control and management solutions, in particular, advanced power strips (APSs) was studied. The project evaluated the market potential for Smart Power Strips (SPSs) with load identification and the likely impact of a load identification feature on APS adoption and effectiveness. The project also identified other success factors required for widespread APS adoption and market acceptance. Even though the developed technology is applicable for both residential and commercial buildings, this project is focused on effective plug-in load control and management for commercial buildings, accomplished through effective load identification. The project has completed Smart Receptacle (SR) prototype development with integration of Load ID, Control/Management, WiFi communication, and Web Service. Twenty SR units were built, tested, and demonstrated in the Eaton lab; eight SR units were tested in the National Renewable Energy Lab (NREL) for one-month of field testing. Load ID algorithm testing for extended load sets was conducted within the Eaton facility and at local university campuses. This report is to summarize the major achievements, activities, and outcomes under the execution of the project.« less
NASA Astrophysics Data System (ADS)
De Lucia, Marco; Kühn, Michael
2015-04-01
The 3D imaging of porous media through micro tomography allows the characterization of porous space and mineral abundances with unprecedented resolution. Such images can be used to perform computational determination of permeability and to obtain a realistic measure of the mineral surfaces exposed to fluid flow and thus to chemical interactions. However, the volume of the plugs that can be analysed with such detail is in the order of 1 cm3, so that their representativity at a larger scale, i.e. as needed for reactive transport modelling at Darcy scale, is questionable at best. In fact, the fine scale heterogeneity (from plug to plug at few cm distance within the same core) would originate substantially different readings of the investigated properties. Therefore, a comprehensive approach including the spatial variability and heterogeneity at the micro- and plug scale needs to be adopted to gain full advantage from the high resolution images in view of the upscaling to Darcy scale. In the framework of the collaborative project H2STORE, micro-CT imaging of different core samples from potential H2-storage sites has been performed by partners at TU Clausthal and Jena University before and after treatment with H2/CO2 mixtures in pressurized autoclaves. We present here the workflow which has been implemented to extract the relevant features from the available data concerning the heterogeneity of the medium at the microscopic and plug scale and to correlate the observed chemical reactions and changes in the porous structure with the geometrical features of the medium. First, a multivariate indicator-based geostatistical model for the microscopic structure of the plugs has been built and fitted to the available images. This involved the implementation of exploratory analysis algorithms such as experimental indicator variograms and cross-variograms. The implemented methods are able to efficiently deal with images in the order of 10003 voxels making use of parallelization. Sequential Indicator Simulations are then employed to generate equi-probable realizations of microscopic structures with varying mineral proportions and porosity but constrained to the spatial variability observed in the plugs. The statistics computed on the ensemble of realizations (essentially the distribution of mineral reactive surfaces exposed to porous space) is integrated at a larger, Darcy scale. In a further step, the analysis of the microscopic changes in the plugs after exposure to reactive solution establishes the correlations betweens amount of chemical reactions and changes in the spatial models, thus deriving some effective correlations which can be injected into the reactive transport modelling. In this contribution, we demonstrate the implemented workflow on a series of images obtained from plugs from a german depleted gas field exposed to H2 and CO2-charged brines. The geostatistical evaluation of microscale variability of the porous media contributes to the upscaling of relevant variables and helps estimating - if not reducing - the uncertainty due to the heterogeneity across scales of the natural systems.
Plug-in connector socket accepts coaxial cable end
NASA Technical Reports Server (NTRS)
Mitchell, D.; Van Loon, J.
1966-01-01
Connector which includes a spring-loaded contact to receive a protruding center conductor and an internal collet to clamp against a collar attached to a woven outer conductor, is used as a receptacle for the end of a coaxial cable. This plug-in connector socket is used successfully with remote manipulators.
Circuit reliability boosted by soldering pins of disconnect plugs to sockets
NASA Technical Reports Server (NTRS)
Pierce, W. B.
1964-01-01
Where disconnect pins must be used for wiring and testing a circuit, improved system reliability is obtained by making a permanent joint between pins and sockets of the disconnect plug. After the circuit has been tested, contact points may be fused through soldering, brazing, or welding.
Code of Federal Regulations, 2011 CFR
2011-07-01
...://www.iec.ch/: (1) IEC 309-1—Plugs, Socket-Outlets and Couplers for Industrial Purposes: Part 1, General Requirements, 1979, IBR approved for § 154.812. (2) IEC 309-2—Plugs, Socket-Outlets and Couplers for Industrial...
Code of Federal Regulations, 2012 CFR
2012-07-01
...://www.iec.ch/: (1) IEC 309-1—Plugs, Socket-Outlets and Couplers for Industrial Purposes: Part 1, General Requirements, 1979, IBR approved for § 154.812. (2) IEC 309-2—Plugs, Socket-Outlets and Couplers for Industrial...
Consumer adoption and grid impact models for plug-in hybrid electric vehicles in Wisconsin.
DOT National Transportation Integrated Search
2010-05-01
This proposed study focuses on assessing the demand for plug-in hybrid electric vehicles (PHEV) in Wisconsin and its economic : impacts on the States energy market and the electric grid. PHEVs are expected to provide a range of about 40 miles per ...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Septon, Kendall K
Electric-drive vehicles use electricity as their primary fuel or to improve the efficiency of conventional vehicle designs. These vehicles can be divided into three categories: Hybrid electric vehicles (HEVs), Plug-in hybrid electric vehicles (PHEVs), All-electric vehicles (EVs). Together, PHEVs and EVs can also be referred to as plug-in electric vehicles (PEVs).
40 CFR 86.1816-18 - Emission standards for heavy-duty vehicles.
Code of Federal Regulations, 2014 CFR
2014-07-01
... as specified in this section. (4) Measure emissions from hybrid electric vehicles (including plug-in hybrid electric vehicles) as described in 40 CFR part 1066, subpart F, except that these procedures do not apply for plug-in hybrid electric vehicles during charge-depleting operation. (b) Tier 3 exhaust...
Plug-in Sensors for Air Pollution Monitoring.
ERIC Educational Resources Information Center
Shaw, Manny
Faristors, a type of plug-in sensors used in analyzing equipment, are described in this technical report presented at the 12th Conference on Methods in Air Pollution and Industrial Hygiene Studies, University of Southern California, April, 1971. Their principles of operation, interchangeability, and versatility for measuring air pollution at…
Energy Storage Laboratory | Energy Systems Integration Facility | NREL
technologies. Key Infrastructure Energy storage system inverter, energy storage system simulators, research Plug-In Vehicles/Mobile Storage The plug-in vehicles/mobile storage hub includes connections for small integration. Key Infrastructure Ample house power, REDB access, charging stations, easy vehicle parking access
30 CFR 250.1615 - Securing of wells.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 30 Mineral Resources 2 2014-07-01 2014-07-01 false Securing of wells. 250.1615 Section 250.1615... of wells. A downhole-safety device such as a cement plug, bridge plug, or packer shall be timely... drilling crew, prevent station keeping, or require repairs to major drilling units or well-control...
30 CFR 250.1615 - Securing of wells.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 30 Mineral Resources 2 2012-07-01 2012-07-01 false Securing of wells. 250.1615 Section 250.1615... of wells. A downhole-safety device such as a cement plug, bridge plug, or packer shall be timely... drilling crew, prevent station keeping, or require repairs to major drilling units or well-control...
Charging Rate Incentive - Georgia Power Georgia Power offers a Plug-in Electric Vehicle (PEV) time -of-use electricity rate for residential customers who own an electric or plug-in hybrid electric vehicle. The PEV rate is optional and does not require a separate meter. For more information, see the
Integrated, Kerberized Login on MacOS X
NASA Technical Reports Server (NTRS)
Hotz, Henry B.
2006-01-01
Context for this information. MacOS X login process and available hooks. Authorization Services configuration. Authorization Services plug-in s. Kerberos plug-in s. Other bugs and recommendations. Authorization Services Called by loginwindow, screen saver and fast user switching. It calls Directory Services, Login Hook, and Login Items (System Preferences).
Viewing Files — EDRN Public Portal
In addition to standard HTML Web pages, our web site contain other file formats. You may need additional software or browser plug-ins to view some of the information available on our site. This document lists show each format, along with links to the corresponding freely available plug-ins or viewers.
In addition to standard HTML webpages, our website contains files in other formats. You may need additional software or browser plug-ins to view some of these files. The following list shows each format along with links to the corresponding freely available plug-ins or viewers. Documents Adobe Acrobat Reader (.pdf)
Electric and Plug-In Hybrid Electric Vehicle Publications | Transportation
, Kandler Smith, and Kevin Walkowicz. (2016) Medium-Duty Plug-in Electric Delivery Truck Fleet Evaluation . (2014) Smith Newton Electric Delivery Trucks Smith Newton Vehicle Performance Evaluation (Gen 1 ), Cumulative Report: November 2011-June 2014. Adam Ragatz. (2014) Smith Newton Vehicle Performance Evaluation
21 CFR 878.4755 - Absorbable lung biopsy plug.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Absorbable lung biopsy plug. 878.4755 Section 878.4755 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4755 Absorbable lung biopsy...
78 FR 5327 - Medical Devices; Ophthalmic Devices; Classification of the Scleral Plug
Federal Register 2010, 2011, 2012, 2013, 2014
2013-01-25
... Agency) is proposing to classify the scleral plug into class II (special controls), and proposing to... controls needed to provide reasonable assurance of their safety and effectiveness. The three categories of devices are class I (general controls), class II (special controls), and class III (premarket approval...
PORTABLE SOURCE OF RADIOACTIVITY
Goertz, R.C.; Ferguson, K.R.; Rylander, E.W.; Safranski, L.M.
1959-06-16
A portable source for radiogiaphy or radiotherapy is described. It consists of a Tl/sup 170/ or Co/sup 60/ source mounted in a rotatable tungsten alloy plug. The plug rotates within a brass body to positions of safety or exposure. Provision is made for reloading and carrying the device safely. (T.R.H.)
A biphasic oxidation of alcohols to aldehydes and ketones using a simplified packed-bed microreactor
Bogdan, Andrew
2009-01-01
Summary We demonstrate the preparation and characterization of a simplified packed-bed microreactor using an immobilized TEMPO catalyst shown to oxidize primary and secondary alcohols via the biphasic Anelli-Montanari protocol. Oxidations occurred in high yields with great stability over time. We observed that plugs of aqueous oxidant and organic alcohol entered the reactor as plugs but merged into an emulsion on the packed-bed. The emulsion coalesced into larger plugs upon exiting the reactor, leaving the organic product separate from the aqueous by-products. Furthermore, the microreactor oxidized a wide range of alcohols and remained active in excess of 100 trials without showing any loss of catalytic activity. PMID:19478910
Electromagnetic Analysis of ITER Diagnostic Equatorial Port Plugs During Plasma Disruptions
DOE Office of Scientific and Technical Information (OSTI.GOV)
Y. Zhai, R. Feder, A. Brooks, M. Ulrickson, C.S. Pitcher and G.D. Loesser
2012-08-27
ITER diagnostic port plugs perform many functionsincluding structural support of diagnostic systems under high electromagnetic loads while allowing for diagnostic access to the plasma. The design of diagnostic equatorial port plugs (EPP) are largely driven by electromagnetic loads and associate responses of EPP structure during plasma disruptions and VDEs. This paper summarizes results of transient electromagnetic analysis using Opera 3d in support of the design activities for ITER diagnostic EPP. A complete distribution of disruption loads on the Diagnostic First Walls (DFWs), Diagnostic Shield Modules (DSMs) and the EPP structure, as well as impact on the system design integration duemore » to electrical contact among various EPP structural components are discussed.« less
Solar Cell Modules With Improved Backskin
Chevrefils, Andre; Grigore, Daniel Gheorghe
2001-01-23
The present invention relates to gas turbines and more particularly to a device for controlling the flow of cooling air through a flowpath in a turbine blade. The device can be inserted in the inlet opening of the blade flowpath and be retained therein. The device comprises a plug member for adjusting the flow of cooling air through the flowpath. The plug member comprises a retaining portion for retaining the plug member at the inlet opening of the flowpath and a blocking portion inserted within the flowpath for reducing the cross-sectional area of the inlet opening. Such a device is inexpensive and can be easily inserted in the inlet opening of a blade flowpath and retained therein.
The automation of an inlet mass flow control system
NASA Technical Reports Server (NTRS)
Supplee, Frank; Tcheng, Ping; Weisenborn, Michael
1989-01-01
The automation of a closed-loop computer controlled system for the inlet mass flow system (IMFS) developed for a wind tunnel facility at Langley Research Center is presented. This new PC based control system is intended to replace the manual control system presently in use in order to fully automate the plug positioning of the IMFS during wind tunnel testing. Provision is also made for communication between the PC and a host-computer in order to allow total animation of the plug positioning and data acquisition during the complete sequence of predetermined plug locations. As extensive running time is programmed for the IMFS, this new automated system will save both manpower and tunnel running time.
Electrokinetic focusing injection methods on microfluidic devices.
Fu, Lung-Ming; Yang, Ruey-Jen; Lee, Gwo-Bin
2003-04-15
This paper presents an experimental and numerical investigation into electrokinetic focusing injection on microfluidic chips. The valving characteristics on microfluidic devices are controlled through appropriate manipulations of the electric potential strengths during the sample loading and dispensing steps. The present study also addresses the design and testing of various injection systems used to deliver a sample plug. A novel double-cross injection microfluidic chip is fabricated, which employs electrokinetic focusing to deliver sample plugs of variable volume. The proposed design combines several functions of traditional sample plug injection systems on a single microfluidic chip. The injection technique uses an unique sequence of loading steps with different electric potential distributions and magnitudes within the various channels to effectuate a virtual valve.
NASA Astrophysics Data System (ADS)
Ezoe, Yuichiro; Ishikawa, Kumi; Mitsuishi, Ikuyuki; Ohashi, Takaya; Mitsuda, Kazuhisa; Fujimoto, Ryuichi; Murakami, Masahide; Kanao, Kenichi; Yoshida, Seiji; Tsunematsu, Shoji; DiPirro, Michael; Shirron, Peter
2016-07-01
Suppression of super fluid helium flow is critical for the Soft X-ray Spectrometer onboard ASTRO-H (Hitomi). In nominal operation, a small helium gas flow of 30 μg/s must be safely vented and a super fluid film flow must be sufficiently small <2 μg/s. To achieve a life time of the liquid helium, a porous plug phase separator and a film flow suppression system composed of an orifice, a heat exchanger, and knife edge devices are employed. In this paper, design, on-ground testing results and in-orbit performance of the porous plug and the film flow suppression system are described.
30 CFR 250.502 - Equipment movement.
Code of Federal Regulations, 2013 CFR
2013-07-01
... District Manager. A closed surface-controlled subsurface safety valve of the pump-through type may be used in lieu of the pump-through-type tubing plug, provided that the surface control has been locked out... be shut in below the surface with a pump-through-type tubing plug and at the surface with a closed...
30 CFR 250.602 - Equipment movement.
Code of Federal Regulations, 2011 CFR
2011-07-01
... otherwise approved by the District Manager. A closed surface-controlled subsurface safety valve of the pump-through-type may be used in lieu of the pump-through-type tubing plug provided that the surface control... producing hydrocarbons shall be shut in below the surface with a pump-through-type tubing plug and at the...
30 CFR 250.602 - Equipment movement.
Code of Federal Regulations, 2012 CFR
2012-07-01
... District Manager. A closed surface-controlled subsurface safety valve of the pump-through-type may be used in lieu of the pump-through-type tubing plug provided that the surface control has been locked out of... be shut in below the surface with a pump-through-type tubing plug and at the surface with a closed...
30 CFR 250.602 - Equipment movement.
Code of Federal Regulations, 2013 CFR
2013-07-01
... District Manager. A closed surface-controlled subsurface safety valve of the pump-through-type may be used in lieu of the pump-through-type tubing plug provided that the surface control has been locked out of... be shut in below the surface with a pump-through-type tubing plug and at the surface with a closed...
30 CFR 250.502 - Equipment movement.
Code of Federal Regulations, 2014 CFR
2014-07-01
... District Manager. A closed surface-controlled subsurface safety valve of the pump-through type may be used in lieu of the pump-through-type tubing plug, provided that the surface control has been locked out... be shut in below the surface with a pump-through-type tubing plug and at the surface with a closed...
30 CFR 250.502 - Equipment movement.
Code of Federal Regulations, 2011 CFR
2011-07-01
... otherwise approved by the District Manager. A closed surface-controlled subsurface safety valve of the pump-through type may be used in lieu of the pump-through-type tubing plug, provided that the surface control... producing hydrocarbons shall be shut in below the surface with a pump-through-type tubing plug and at the...
30 CFR 250.602 - Equipment movement.
Code of Federal Regulations, 2014 CFR
2014-07-01
... District Manager. A closed surface-controlled subsurface safety valve of the pump-through-type may be used in lieu of the pump-through-type tubing plug provided that the surface control has been locked out of... be shut in below the surface with a pump-through-type tubing plug and at the surface with a closed...
30 CFR 250.502 - Equipment movement.
Code of Federal Regulations, 2012 CFR
2012-07-01
... District Manager. A closed surface-controlled subsurface safety valve of the pump-through type may be used in lieu of the pump-through-type tubing plug, provided that the surface control has been locked out... be shut in below the surface with a pump-through-type tubing plug and at the surface with a closed...
The main objective of the feasibility study described here was to test the hypothesis that properly plugged wells are effectively sealed by drilling mud. In The process of testing the hypothesis, evidence about dynamics of building mud cake on the wellbore-face was obtained, as ...
78 FR 11639 - Dominion Transmission, Inc.; Notice of Request Under Blanket Authorization
Federal Register 2010, 2011, 2012, 2013, 2014
2013-02-19
... under the Natural Gas Act (NGA) as amended, to plug and abandon two storage wells and their associated... plug wells JW-451F and JW-454F and their associated pipelines located near the Murrysville Pool of the.... Dominion further states that the certificated physical parameters, including total natural gas inventory...
Code of Federal Regulations, 2012 CFR
2012-07-01
... ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) ENERGY POLICY FUEL ECONOMY AND GREENHOUSE GAS EXHAUST EMISSIONS OF MOTOR VEHICLES Fuel Economy and Carbon-Related Exhaust Emission Test Procedures § 600.116-12 Special procedures related to electric vehicles and plug-in hybrid electric vehicles. (a) Determine fuel economy...
24 CFR 3280.610 - Drainage systems.
Code of Federal Regulations, 2012 CFR
2012-04-01
... individually vented. (iii) A 3-inch minimum diameter piping shall be required for water closets. (f) Wet-vented... water seal trap (§ 3280.606(a)). (2) The drainage system shall be designed to provide an adequate... equipped with a water-tight cap or plug matching the drain outlet. The cap or plug shall be permanently...
24 CFR 3280.610 - Drainage systems.
Code of Federal Regulations, 2013 CFR
2013-04-01
... individually vented. (iii) A 3-inch minimum diameter piping shall be required for water closets. (f) Wet-vented... water seal trap (§ 3280.606(a)). (2) The drainage system shall be designed to provide an adequate... equipped with a water-tight cap or plug matching the drain outlet. The cap or plug shall be permanently...
Walker, D.E.; Matras, S.
1963-04-30
This patent shows a method of making a fuel or control rod for a nuclear reactor. Fuel or control material is placed within a tube and plugs of porous metal wool are inserted at both ends. The metal wool is then compacted and the tube compressed around it as by swaging, thereby making the plugs liquid- impervious but gas-pervious. (AEC)
Alternative Fuels Data Center: Availability of Hybrid and Plug-In Electric
AddThis.com... More in this section... Electricity Basics Benefits & Considerations Stations Vehicles electricity to improve fuel efficiency. Pre-Owned Vehicles Learn about buying and selling pre-owned and plug-in electric vehicles. Learn more about the benefits and considerations of electricity as a
USDA-ARS?s Scientific Manuscript database
The specific objectives of this study were to evaluate headspace aeration for reducing hydrogen sulfide levels in low cost plug flow digesters, and to characterize the relationship between the liquid surface area and hydrogen sulfide oxidation rates. Experiments with replicate field scale plug flow ...
30 CFR 250.1615 - Securing of wells.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 30 Mineral Resources 2 2011-07-01 2011-07-01 false Securing of wells. 250.1615 Section 250.1615... § 250.1615 Securing of wells. A downhole-safety device such as a cement plug, bridge plug, or packer... evacuation of the drilling crew, prevent station keeping, or require repairs to major drilling units or well...
Mangold, A.J. Jr.; MaHaffey, J.W.; Reese, S.L.
1958-04-29
An improved ingot-mold assembly is described, consisting of a body having a cavity and a recess extending through to the bottom of the body from the cavity, and the bottom of the cavity having an internal shoulder extending downward and a plug having an external shoulder. The plug extends above the shoulders and below the bottom of the body.
30 CFR 75.831 - Electrical work; troubleshooting and testing.
Code of Federal Regulations, 2010 CFR
2010-07-01
... disconnecting device: (i) Remove the plug from the power receptacle and connect it to the grounding receptacle... coupler is used as a disconnecting device: (i) Remove the plug from the power receptacle and connect it to...) or (2): (1) If a trailing cable disconnecting switch is provided: (i) Open and ground the power...
Internet Wargaming with Distributed Processing Using the Client-Server Model
1997-03-01
in for war game development . There are tool kits for writing binary files that are interpreted by a particular plug-in. The most popular plug-in set...multi-player game development , the speed with which the environment is changing should be taken into 35 account. For this project JavaScript was chosen
Code of Federal Regulations, 2010 CFR
2010-07-01
... Waste Injection Wells § 146.71 Closure. (a) Closure Plan. The owner or operator of a Class I hazardous waste injection well shall prepare, maintain, and comply with a plan for closure of the well that meets... of material to be used in plugging; (iv) The method of placement of the plugs; (v) Any proposed test...
Kayser, Ole; Schäfer, Philipp
2013-01-01
Although endovascular transcatheter embolization of arteriovenous fistulas is minimally invasive, the torrential flow prevailing within a fistula implies the risk of migration of the deployed embolization devices into the downstream venous and pulmonary circulation. We present the endovascular treatment of a giant postnephrectomy arteriovenous fistula between the right renal pedicle and the residual renal vein in a 63-year-old man. The purpose of this case report is to demonstrate that the Amplatzer vascular plug (AVP) can be safely positioned to embolize even relatively large arteriovenous fistulas (AVFs). Secondly, we illustrate that this occluder can even be introduced to the fistula via a transvenous catheter in cases where it is initially not possible to advance the deployment-catheter through a tortuous feeder artery. Migration of the vascular plug was ruled out at follow-up 4 months subsequently to the intervention. Thus, the Amplatzer vascular plug and the arteriovenous through-and-through guide wire access with subsequent transvenous deployment should be considered in similar cases. PMID:23326248
Integrating plug-in electric vehicles into the electric power system
NASA Astrophysics Data System (ADS)
Wu, Di
This dissertation contributes to our understanding of how plug-in hybrid electric vehicles (PHEVs) and plug-in battery-only electric vehicles (EVs)---collectively termed plug-in electric vehicles (PEVs)---could be successfully integrated with the electric power system. The research addresses issues at a diverse range of levels pertaining to light-duty vehicles, which account for the majority of highway vehicle miles traveled, energy consumed by highway travel modes, and carbon dioxide emissions from on-road sources. Specifically, the following topics are investigated: (i) On-board power electronics topologies for bidirectional vehicle-to-grid and grid-to-vehicle power transfer; (ii) The estimation of the electric energy and power consumption by fleets of light-duty PEVs; (iii) An operating framework for the scheduling and dispatch of electric power by PEV aggregators; (iv) The pricing of electricity by PHEV aggregators and how it affects the decision-making process of a cost-conscious PHEV owner; (v) The impacts on distribution systems from PEVs under aggregator control; (vi) The modeling of light-duty PEVs for long-term energy and transportation planning at a national scale.
Board-to-board optical interconnection using novel optical plug and slot
NASA Astrophysics Data System (ADS)
Cho, In K.; Yoon, Keun Byoung; Ahn, Seong H.; Kim, Jin Tae; Lee, Woo Jin; Shin, Kyoung Up; Heo, Young Un; Park, Hyo Hoon
2004-10-01
A novel optical PCB with transmitter/receiver system boards and optical bakcplane was prepared, which is board-to-board interconnection by optical plug and slot. We report an 8Gb/s PRBS NRZ data transmission between transmitter system board and optical backplane embedded multimode polymeric waveguide arrays. The basic concept of ETRI's optical PCB is as follows; 1) Metal optical bench is integrated with optoelectronic devices, driver and receiver circuits, polymeric waveguide and access line PCB module. 2) Multimode polymeric waveguide inside an optical backplane, which is embedded into PCB. 3) Optical slot and plug for high-density(channel pitch : 500um) board-to-board interconnection. The polymeric waveguide technology can be used for transmission of data on transmitter/ receiver system boards and for backplane interconnections. The main components are low-loss tapered polymeric waveguides and a novel optical plug and slot for board-to-board interconnections, respectively. The optical PCB is characteristic of low coupling loss, easy insertion/extraction of the boards and, especially, reliable optical coupling unaffected from external environment after board insertion.
Luo, Yong; Wu, Dapeng; Zeng, Shaojiang; Gai, Hongwei; Long, Zhicheng; Shen, Zheng; Dai, Zhongpeng; Qin, Jianhua; Lin, Bingcheng
2006-09-01
A novel sample injection method for chip CE was presented. This injection method uses hydrostatic pressure, generated by emptying the sample waste reservoir, for sample loading and electrokinetic force for dispensing. The injection was performed on a double-cross microchip. One cross, created by the sample and separation channels, is used for formation of a sample plug. Another cross, formed by the sample and controlling channels, is used for plug control. By varying the electric field in the controlling channel, the sample plug volume can be linearly adjusted. Hydrostatic pressure takes advantage of its ease of generation on a microfluidic chip, without any electrode or external pressure pump, thus allowing a sample injection with a minimum number of electrodes. The potential of this injection method was demonstrated by a four-separation-channel chip CE system. In this system, parallel sample separation can be achieved with only two electrodes, which is otherwise impossible with conventional injection methods. Hydrostatic pressure maintains the sample composition during the sample loading, allowing the injection to be free of injection bias.
Plug cluster engine concept for in-space missions
NASA Technical Reports Server (NTRS)
Obrien, C. J.; Aukerman, C. A.
1979-01-01
The development of a suitable orbital transfer vehicle (OTV) engine is discussed. The OTV's dimensions are limited by those of the Space Shuttle payload bay on which it will be carried. An approach to utilize the available diameter to achieve high area ratio and thus high engine performance, is presented. Unconventional nozzles, such as clusters of small thrusters around a large diameter contoured plug, are investigated to arrive at engine designs which feature lower chamber pressures, with attendant lower heat flux, lower wall temperature, longer fatigue life, and less critical turbomachinery. Attention is also given to plug nozzle technology, high area ratio module- and scarfed bell- Plug Cluster Engine (PCE) concepts, as well as PCE performance, weight, and assessment. A conceptual design of a PCE formed from a cluster of high area ratio, scarfed, bell nozzles proved to be competitive with bell and spike nozzle engines. PCE advantages cited include increased payload length due to shorter engine length, ability to increase or decrease the number of modules and thereby the thrust, and low cost due to utilization of off-the-shelf technology.
An Energy Saving Green Plug Device for Nonlinear Loads
NASA Astrophysics Data System (ADS)
Bloul, Albe; Sharaf, Adel; El-Hawary, Mohamed
2018-03-01
The paper presents a low cost a FACTS Based flexible fuzzy logic based modulated/switched tuned arm filter and Green Plug compensation (SFC-GP) scheme for single-phase nonlinear loads ensuring both voltage stabilization and efficient energy utilization. The new Green Plug-Switched filter compensator SFC modulated LC-Filter PWM Switched Capacitive Compensation Devices is controlled using a fuzzy logic regulator to enhance power quality, improve power factor at the source and reduce switching transients and inrush current conditions as well harmonic contents in source current. The FACTS based SFC-GP Device is a member of family of Green Plug/Filters/Compensation Schemes used for efficient energy utilization, power quality enhancement and voltage/inrush current/soft starting control using a dynamic error driven fuzzy logic controller (FLC). The device with fuzzy logic controller is validated using the Matlab / Simulink Software Environment for enhanced power quality (PQ), improved power factor and reduced inrush currents. This is achieved using modulated PWM Switching of the Filter-Capacitive compensation scheme to cope with dynamic type nonlinear and inrush cyclical loads..
NASA Technical Reports Server (NTRS)
Horton, Karla Renee
2011-01-01
Friction stir welding (FSW) is a solid state welding process with potential advantages for aerospace and automotive industries dealing with light alloys. Self-reacting friction stir welding (SR-FSW) is one variation of the FSW process being developed at the National Aeronautics and Space Administration (NASA) for use in the fabrication of propellant tanks. Friction plug welding is used to seal the exit hole that remains in a circumferential SR-FSW. This work reports on material properties and strain patterns developed in a SR-FSW with a friction plug weld. Specifically, this study examines the behavior of a SR-FSW formed between an AA 2014-T6 plate on the advancing side and an AA 2219-T87 plate on the retreating side and a SR-FSW (AA 2014-T6 to AA 2219-T87) with a 2219-T87 plug weld. This study presents the results of a characterization of the micro-hardness, joint strength, and strain field characterization of SR-FSW and FPW joints tested at room temperature and cryogenic temperatures.
[Plug-in Based Centralized Control System in Operating Rooms].
Wang, Yunlong
2017-05-30
Centralized equipment controls in an operating room (OR) is crucial to an efficient workflow in the OR. To achieve centralized control, an integrative OR needs to focus on designing a control panel that can appropriately incorporate equipment from different manufactures with various connecting ports and controls. Here we propose to achieve equipment integration using plug-in modules. Each OR will be equipped with a dynamic plug-in control panel containing physically removable connecting ports. Matching outlets will be installed onto the control panels of each equipment used at any given time. This dynamic control panel will be backed with a database containing plug-in modules that can connect any two types of connecting ports common among medical equipment manufacturers. The correct connecting ports will be called using reflection dynamics. This database will be updated regularly to include new connecting ports on the market, making it easy to maintain, update, expand and remain relevant as new equipment are developed. Together, the physical panel and the database will achieve centralized equipment controls in the OR that can be easily adapted to any equipment in the OR.
Analysis of stochastic model for non-linear volcanic dynamics
NASA Astrophysics Data System (ADS)
Alexandrov, D.; Bashkirtseva, I.; Ryashko, L.
2014-12-01
Motivated by important geophysical applications we consider a dynamic model of the magma-plug system previously derived by Iverson et al. (2006) under the influence of stochastic forcing. Due to strong nonlinearity of the friction force for solid plug along its margins, the initial deterministic system exhibits impulsive oscillations. Two types of dynamic behavior of the system under the influence of the parametric stochastic forcing have been found: random trajectories are scattered on both sides of the deterministic cycle or grouped on its internal side only. It is shown that dispersions are highly inhomogeneous along cycles in the presence of noises. The effects of noise-induced shifts, pressure stabilization and localization of random trajectories have been revealed with increasing the noise intensity. The plug velocity, pressure and displacement are highly dependent of noise intensity as well. These new stochastic phenomena are related with the nonlinear peculiarities of the deterministic phase portrait. It is demonstrated that the repetitive stick-slip motions of the magma-plug system in the case of stochastic forcing can be connected with drumbeat earthquakes.
NASA Technical Reports Server (NTRS)
Knott, P. R.; Janardan, B. A.; Majjigi, R. K.; Shutiani, P. K.; Vogt, P. G.
1981-01-01
Six coannular plug nozzle configurations having inverted velocity and temperature profiles, and a baseline convergent conical nozzle were tested for simulated flight acoustic evaluation in General Electric's Anechoic Free-Jet Acoustic Facility. The nozzles were tested over a range of test conditions that are typical of a Variable Cycle Engine for application to advanced high speed aircraft. The outer stream radius ratio for most of the configurations was 0.853, and the inner-stream-outer-stream area ratio was tested in the range of 0.54. Other variables investigated were the influence of bypass struts, a simple noncontoured convergent-divergent outer stream nozzle for forward quadrant shock noise control, and the effects of varying outer stream radius and inner-stream-to-outer-stream velocity ratios on the flight noise signatures of the nozzles. It was found that in simulated flight, the high-radius-ratio coannular plug nozzles maintain their jet noise and shock noise reduction features previously observed in static testing. The presence of nozzle bypass structs will not significantly effect the acoustic noise reduction features of a General Electric-type nozzle design. A unique coannular plug nozzle flight acoustic spectral prediction method was identified and found to predict the measured results quite well. Special laser velocimeter and acoustic measurements were performed which have given new insight into the jet and shock noise reduction mechanisms of coannular plug nozzles with regard to identifying further beneficial research efforts.
Deeken, Corey R.; Matthews, Brent D.
2013-01-01
Purpose. Poly-4-hydroxybutyrate (P4HB) is a naturally derived, absorbable polymer. P4HB has been manufactured into PHASIX Mesh and P4HB Plug designs for soft tissue repair. The objective of this study was to evaluate mechanical strength, resorption properties, and histologic characteristics in a porcine model. Methods. Bilateral defects were created in the abdominal wall of n = 20 Yucatan minipigs and repaired in a bridged fashion with PHASIX Mesh or P4HB Plug fixated with SorbaFix or permanent suture, respectively. Mechanical strength, resorption properties, and histologic characteristics were evaluated at 6, 12, 26, and 52 weeks (n = 5 each). Results. PHASIX Mesh and P4HB Plug repairs exhibited similar burst strength, stiffness, and molecular weight at all time points, with no significant differences detected between the two devices (P > 0.05). PHASIX Mesh and P4HB Plug repairs also demonstrated significantly greater burst strength and stiffness than native abdominal wall at all time points (P < 0.05), and material resorption increased significantly over time (P < 0.001). Inflammatory infiltrates were mononuclear, and both devices exhibited mild to moderate granulation tissue/vascularization. Conclusions. PHASIX Mesh and P4HB Plug demonstrated significant mechanical strength compared to native abdominal wall, despite significant material resorption over time. Histological assessment revealed a comparable mild inflammatory response and mild to moderate granulation tissue/vascularization. PMID:23781348
Monitoring techniques for high accuracy interference fit assembly processes
NASA Astrophysics Data System (ADS)
Liuti, A.; Vedugo, F. Rodriguez; Paone, N.; Ungaro, C.
2016-06-01
In the automotive industry, there are many assembly processes that require a high geometric accuracy, in the micrometer range; generally open-loop controllers cannot meet these requirements. This results in an increased defect rate and high production costs. This paper presents an experimental study of interference fit process, aimed to evaluate the aspects which have the most impact on the uncertainty in the final positioning. The press-fitting process considered, consists in a press machine operating with a piezoelectric actuator to press a plug into a sleeve. Plug and sleeve are designed and machined to obtain a known interference fit. Differential displacement and velocity measurements of the plug with respect to the sleeve are measured by a fiber optic differential laser Doppler vibrometer. Different driving signals of the piezo actuator allow to have an insight into the differences between a linear and a pulsating press action. The paper highlights how the press-fit assembly process is characterized by two main phases: the first is an elastic deformation of the plug and sleeve, which produces a reversible displacement, the second is a sliding of the plug with respect to the sleeve, which results in an irreversible displacement and finally realizes the assembly. The simultaneous measurements of the displacement and the force have permitted to define characteristic features in the signal useful to identify the start of the irreversible movement. These indicators could be used to develop a control logic in a press assembly process.
Comparison of Performance of AN-F-58 Fuel and Gasoline in J34-WE-22 Turbojet Engine
NASA Technical Reports Server (NTRS)
Dowman, Harry W; Younger, George G
1949-01-01
As part of an investigation of the performance of AN-F-58 fuel in various types of turbojet engine, the performance of this fuel in a 3000-pound-thrust turbojet engine has been investigated in an altitude test chamber together with the comparative performance of 62-octane gasoline. The investigation of normal engine performance, which covered a range of engine speeds at altitudes from 5000 to 50,000 feet and flight Mach numbers up to 1.00, showed that both the net thrust and average turbine-outlet temperatures were approximately the same for both fuels. The specific fuel consumption and the combustion efficiency at the maximum engine speeds investigated were approximately the same for both fuels at altitudes up to 35,000 feet, but at an altitude of 50,000 feet the specific fuel consumption was about 9 percent higher and the combustion efficiency was correspondingly lower with the AN-F-58 fuel than with gasoline. The low-engine-speed blow-out limits were about the same for both fuels. Ignition of AN-F-58 fuel with the standard spark plug was possible only with the spark plug in a clean condition; ignition was impossible at all flight conditions investigated when the plug was fouled by an accumulation of liquid fuel from a preceding false start. Use of an extended-electrode spark plug provided satisfactory ignition over a slightly smaller range of altitudes and flight Mach numbers than for gasoline with the standard spark plug.
Sun, Yi; Wang, Chengyue; Chen, Qixin; Liu, Hai; Deng, Chao; Ling, Peixue; Cui, Fu-Zhai
2017-08-01
This study was aimed at assessing the effects of the porous mineralized collagen plug with or without the bilayer mineralized collagen-guided bone regeneration membrane on alveolar ridge preservation in dogs. The third premolars in the bilateral maxilla of mongrel dogs ( N = 12) were extracted. Twenty-four alveolar sockets were thus randomly divided into three groups: membrane + collagen plug (MP, n = 8), nonmembrane + collagen plug (NP, n = 8) and blank group without any implantation (BG, n = 8). Radiographic assessment was carried out immediately and in the 2nd, 6th, and 12th week after surgery. The bone-repairing effects of the two grafts were respectively evaluated by clinical observation, X-ray micro-computed tomography examination, and histological analysis in the 8th and 12th week after surgery. Three groups presented excellent osseointegration without any inflammation or dehiscence. X-ray micro-computed tomography and histological assessment indicated that the ratios of new bone formation of MP group were significantly higher than those of NP group and BG group in the 8th and 12th week after surgery ( P < 0.05). As a result, the porous mineralized collagen plug with or without the bilayer mineralized collagen-guided bone regeneration membrane could reduce the absorption of alveolar ridge compared to BG group, and the combined use of porous mineralized collagen plug and bilayer mineralized collagen-guided bone regeneration could further improve the activity of bone regeneration.
Predicting capillarity of mudrocks for geological storage of CO2
NASA Astrophysics Data System (ADS)
Busch, Andreas; Amann-Hildenbrand, Alexandra
2013-04-01
Various rock types were investigated, with the main focus on the determination and prediction of the capillary breakthrough and snap-off pressure in mudrocks (e.g. shales, siltstones, mudstones). Knowledge about these two critical pressures is important for the prediction of the capillary sealing capacity of CO2 storage sites. Capillary pressure experiments, when performed on low-permeable core plugs, are difficult and time consuming. Laboratory measurements on core plugs under in-situ conditions are mostly performed using nitrogen, but also with methane and carbon dioxide. Therefore, mercury porosimetry measurements (MIP) are preferably used in the industry to determine an equivalent value for the capillary breakthrough pressure. These measurements have the advantage to be quick and cheap and only require cuttings or trim samples. When evaluating the database in detail we find that (1) MIP data plot well with the drainage breakthrough pressures determined on sample plugs, while the conversion of the system Hg/air to CO2/brine using interfacial and wettability data does not provide a uniform match, potentially caused by non fully water-wet conditions; (2) brine permeability versus capillary breakthrough pressure determined on sample plugs shows a good match and could provide a first estimate of Pc-values since permeability is easier to determine than capillary breakthrough pressures. For imbibition snap-off pressures a good correlation was found for CH4 measured on sample plugs only; (3) porosity shows a fairly good correlation with permeability for sandstone only, and with plug-derived capillary breakthrough pressures for sandstones, carbonates and evaporates. No such correlations exist for mudrocks; (4) air and brine-derived permeabilities show an excellent correlation and (5) from the data used we do not infer any direct correlations between specific surface area (SSA), mineralogy or organic carbon content with permeability or capillary pressure however were able to predict permeabilities using a more sophisticated model that relies on several of these parameters.
Alternate tube plugging criteria for steam generator tubes
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cueto-Felgueroso, C.; Aparicio, C.B.
1997-02-01
The tubing of the Steam Generators constitutes more than half of the reactor coolant pressure boundary. Specific requirements governing the maintenance of steam generator tubes integrity are set in Plant Technical Specifications and in Section XI of the ASME Boiler and Pressure Vessel Code. The operating experience of Steam Generator tubes of PWR plants has shown the existence of some types of degradatory processes. Every one of these has an specific cause and affects one or more zones of the tubes. In the case of Spanish Power Plants, and depending on the particular Plant considered, they should be mentioned themore » Primary Water Stress Corrosion Cracking (PWSCC) at the roll transition zone (RTZ), the Outside Diameter Stress Corrosion Cracking (ODSCC) at the Tube Support Plate (TSP) intersections and the fretting with the Anti-Vibration Bars (AVBs) or with the Support Plates in the preheater zone. The In-Service Inspections by Eddy Currents constitutes the standard method for assuring the SG tubes integrity and they permit the monitoring of the defects during the service life of the plant. When the degradation reaches a determined limit, called the plugging limit, the SG tube must be either repaired or retired from service by plugging. Customarily, the plugging limit is related to the depth of the defect. Such depth is typically 40% of the wall thickness of the tube and is applicable to any type of defect in the tube. In its origin, that limit was established for tubes thinned by wastage, which was the predominant degradation in the seventies. The application of this criterion for axial crack-like defects, as, for instance, those due to PWSCC in the roll transition zone, has lead to an excessive and unnecessary number of tubes being plugged. This has lead to the development of defect specific plugging criteria. Examples of the application of such criteria are discussed in the article.« less
Ferrari, Enrico; Demertzis, Stefanos; Angelella, Jennifer; Berdajs, Denis; Tozzi, Piergiorgio; Moccetti, Tiziano; Maisano, Francesco; von Segesser, Ludwig K
2017-05-01
Transapical valve implantation is traditionally performed through a left antero-lateral mini-thoracotomy. A self-expandable apical closure device has recently been developed for full-percutaneous transapical valve implantation. We performed haemodynamics stress-tests on an animal model to evaluate the sealing properties. Under general anaesthesia 5 pigs (mean weight: 67 ± 6 Kg) received full heparinization (100 IU/Kg; activated clotting time >250 s and, through inferior mini-sternotomies, 21-Fr introducer sheaths for transapical aortic valve implantation (outer diameter: 25-Fr) were placed over-the-wire in the apexes. Delivery-catheters carrying folded occluders (SAFEX TM final design) were inserted in the introducer sheaths and plugs were then deployed under fluoroscopic guidance. Phase 1: after protamine injection, apical bleeding was monitored for 1 h with standard haemodynamics condition. Phase 2: we induced systemic hypertension with adrenaline infusion to test the sealing properties under stress. Animals were sacrificed after Phase 2 and hearts were removed and inspected. Five plugs were successfully introduced and deployed in 5 pig hearts. Plugs provided good apical sealing in each animal and a mean of 7 ± 4 ml of blood lost per animal was collected during Phase 1: haemodynamics remained stable and no plug dislodgement was detected (mean blood pressure: 52 ± 9 mmHg). During Phase 2, mean systolic and diastolic peak levels reached 268 ± 24 mmHg and 175 ± 17 mmHg, respectively, without plug dislodgment or bleeding. Post-mortem inspection showed good plug deployment and fixation without myocardial damage. The new apical occluder seals large-sized apical access sites in animal models also during induced systemic hypertension. This pilot study is a further step towards full-percutaneous transapical valve procedures in the clinical setting. © The Author 2017. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.
Extrusion cycles of dome-forming eruptions
NASA Astrophysics Data System (ADS)
de'Michieli Vitturi, M.; Clarke, A. B.; Neri, A.; Voight, B.
2010-12-01
We investigated the dynamics of magma ascent along a dome-forming conduit coupled with the formation and extrusion of a degassed plug at the top by a two-phase flow model. We treated the magma mixture as a liquid continuum with dispersed gas bubbles and crystals in thermodynamic equilibrium with the melt. A modified Poiseulle form of the viscous term for fully developed laminar flow in an elliptic conduit was assumed. During ascent, magma pressure decreases and water vapor exsolves and partially degasses from the melt as the melt simultaneously crystallizes, causing changes in mixture density and viscosity, which may eventually lead to the formation of a degassed plug sealing the conduit. The numerical model DOMEFLOW (de’ Michieli Vitturi et al., EPSL 2010) has been applied to dome-building eruptions using conditions approximately appropriate for the Soufrière Hills volcano, Montserrat, which has led to a better understanding of the role of a plug on eruption periodicity. Two mechanisms, which have been proposed to cause periodicity, have been implemented in the model and their corresponding timescales explored. The first test applies a stick-slip model in which the plug is considered as solid and static/dynamic friction, as described in Iverson et al. [Nature 2006, 444, 439-43], replaces the viscous forces in the momentum equation. This mechanism yields cycle timescales of seconds to tens of seconds with values generally depending on assumed friction coefficients. Although not all constants and parameters have been explored for this model, we suggest that a stick-slip mechanism of this type cannot explain the cycles of extrusion and explosion typically observed at Montserrat (timescales of hours). The second mechanism does not consider friction but allows enhanced permeable gas loss in the shallow conduit, possibly due to connected porosity or micro- or macro-scale fractures. Enhanced permeable gas loss may lead to formation of a dense and rheologically stiffened magma plug with high viscosity at the top of the conduit which can resist extrusion and prevent steady conduit flow. The plug produces high pressure in the upper conduit, which can cause edifice inflation. Eventually the pressure increases sufficiently to drive the degassed plug from the conduit, overcoming dome overburden, plug weight, and viscous forces. Extrusion and escape of pressurized gas result in a relaxation of pressure in the upper conduit and allow edifice deflation. In general, cycle period decreases with increasing magma supply rate until a threshold is reached, at which point periodicity disappears and extrusion rate becomes steady. Results are compared to well-documented cyclic phases of the ongoing eruption of the Soufrière Hills volcano, Montserrat, in order to demonstrate the appropriateness of this second formulation.
Expanded plug method for developing circumferential mechanical properties of tubular materials
Hendrich, William Ray; McAfee, Wallace Jefferson; Luttrell, Claire Roberta
2006-11-28
A method for determining the circumferential properties of a tubular product, especially nuclear fuel cladding, utilizes compression of a polymeric plug within the tubular product to determine strain stress, yield stress and other properties. The process is especially useful in the determination of aging properties such as fuel rod embrittlement after long burn-down.
Enhancements to the Redmine Database Metrics Plug in
2017-08-01
management web application has been adopted within the US Army Research Laboratory’s Computational and Information Sciences Directorate as a database...Metrics Plug-in by Terry C Jameson Computational and Information Sciences Directorate, ARL Approved for public... information is estimated to average 1 hour per response, including the time for reviewing instructions, searching existing data sources, gathering and
NASA Technical Reports Server (NTRS)
Vogt, P. G.; Bhutiani, P. K.; Knott, P. R.
1981-01-01
Laser velocimeter data, collected as part of an acoustic investigation of coannular plug nozzles, is provided. The type of traverse, position, and histogram number is given along with the mean and turbulent velocity data. The velocites are normalized with respect to the outer flow velocity and the 'mixed' velocity.
A Bird and Bee Problem in House Siding
Louis F. Wilson; Henry A. Huber
1976-01-01
Plywood house siding made to simulate reverse board-and-batten design is sometimes attacked by woodpeckers because leaf-cutting bees, their prey, make nests in holes in the plywood core. The problem can be prevented by plugging the holes before nesting occurs. If nesting does occur, the nest should be destroyed and then the holes plugged.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Singer, Mark
This presentation includes data captured by the National Renewable Energy Laboratory (NREL) to support the U.S. Department of Energy's Vehicle Technologies Office (VTO) research efforts. The data capture consumer views on fuel economy, plug-in electric vehicle battery range, and willingness to pay for advanced vehicle technologies.
Close-up of 7/8' gold-plated liquid oxygen post plug
NASA Technical Reports Server (NTRS)
1999-01-01
Engineers are investigating the possibility that a 7/8' gold- plated liquid oxygen post plug became dislodged and created three small holes in the liquid hydrogen tubes inside the nozzle on main engine No. 3 on Space Shuttle Columbia. The holes caused a hydrogen leak during the STS-93 launch of Columbia on July 23.
A Rotating Plug Model of Friction Stir Welding Heat Transfer
NASA Technical Reports Server (NTRS)
Raghulapadu J. K.; Peddieson, J.; Buchanan, G. R.; Nunes, A. C.
2006-01-01
A simplified rotating plug model is employed to study the heat transfer phenomena associated with the fiction stir welding process. An approximate analytical solution is obtained based on this idealized model and used both to demonstrate the qualitative influence of process parameters on predictions and to estimate temperatures produced in typical fiction stir welding situations.
30 CFR 250.402 - When and how must I secure a well?
Code of Federal Regulations, 2011 CFR
2011-07-01
..., DEPARTMENT OF THE INTERIOR OFFSHORE OIL AND GAS AND SULPHUR OPERATIONS IN THE OUTER CONTINENTAL SHELF Oil and Gas Drilling Operations General Requirements § 250.402 When and how must I secure a well? Whenever you interrupt drilling operations, you must install a downhole safety device, such as a cement plug, bridge plug...
Alternative Fuels Data Center: Plug-In Hybrid Electric Vehicles
Data Center: Plug-In Hybrid Electric Vehicles on AddThis.com... More in this section... Electricity other propulsion source. Using electricity from the grid to run the vehicle some or all of the time levels of emissions, depending on the electricity source. There are several light-duty PHEVs commercially
Alternative Fuels Data Center: Los Angeles Saves With Hybrid and Plug-In
Electric VehiclesA> Los Angeles Saves With Hybrid and Plug-In Electric Vehicles to someone by E million gallons last year. For information about this project, contact Los Angeles Clean Cities Coalition - Television's Original Automotive Magazine Provided by Maryland Public Television Related Videos Photo of a car
40 CFR 146.10 - Plugging and abandoning Class I, II, III, IV, and V wells.
Code of Federal Regulations, 2011 CFR
2011-07-01
... cement in a manner which will not allow the movement of fluids either into or between underground sources... sources of drinking water. (2) Placement of the cement plugs shall be accomplished by one of the following... alternative method approved by the Director, which will reliably provide a comparable level of protection to...
Thermomechanical force application
NASA Technical Reports Server (NTRS)
Frederking, T. H. K.; Abbassi, P.; Afifi, F.; Chen, W. E. W.; Khandhar, P. K.; Ono, D. Y.
1987-01-01
The present work conducted in Summer 1987 continues investigations on Thermal Components for 1.8 K Space Cryogenics (Grant NAG 1-412 of 1986). The topics addressed are plug characterization efforts in a small pore size regime of sintered metal plugs, characterization in the nonlinear regime, temperature profiles in a heat supply unit for a fountain effect pump and modeling efforts.
Households' Stories of Their Encounters with a Plug-In Hybrid Electric Vehicle
ERIC Educational Resources Information Center
Caperello, Nicolette D.; Kurani, Kenneth S.
2012-01-01
One way to progress toward greenhouse gas reductions is for people to drive plug-in hybrid electric vehicles (PHEVs). Households in this study participated in a 4- to 6-week PHEV driving trial. A narrative of each household's encounter with the PHEV was constructed by the researchers from multiple in-home interviews, questionnaires completed by…
Alternative Fuels Data Center: Plug-In Vehicles to Harness Renewable Energy
state has partnered with the U.S. Department of Energy through the Hawaii Clean Energy Initiative to adoption," Larson said. HCC supports the Hawaii Clean Energy Initiative, a partnership between DOE and Hawaii Clean Energy Initiative Honolulu Clean Cities National Clean Fleets Partnership Hybrid and Plug-In
From Pump to Plug: Measuring the Public's Attitude about Plug-In Electric
-National Benchmark Report, presents the findings of a study on the public's sentiments regarding PEVs, with February 2015, the study covered a 1,015-household sample designed to be representative of the U.S . population. NREL plans to repeat the study annually to track changing consumer perceptions. Consumer Views
HORIZONTAL BEAM HOLE NO. 3. PLUG AND RADIATION DOOR HAVE ...
HORIZONTAL BEAM HOLE NO. 3. PLUG AND RADIATION DOOR HAVE BEEN REMOVED. EXPERIMENTAL APPARATUS WAS INSERTED INTO THE HOLE. NOTE VALVE CUBICLES NEAR FLOOR ON EACH SIDE OF HB-3. INL NEGATIVE NO. 3471. Unknown Photographer, 10/12/1951 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
30 CFR 250.1712 - What information must I submit before I permanently plug a well or zone?
Code of Federal Regulations, 2011 CFR
2011-07-01
... 30 Mineral Resources 2 2011-07-01 2011-07-01 false What information must I submit before I permanently plug a well or zone? 250.1712 Section 250.1712 Mineral Resources BUREAU OF OCEAN ENERGY MANAGEMENT... two independent tested barriers, including one mechanical barrier, across each flow path during...
Electromagnetic Analysis For The Design Of ITER Diagnostic Port Plugs During Plasma Disruptions
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhai, Y
2014-03-03
ITER diagnostic port plugs perform many functions including structural support of diagnostic systems under high electromagnetic loads while allowing for diagnostic access to plasma. The design of diagnotic equatorial port plugs (EPP) are largely driven by electromagnetic loads and associate response of EPP structure during plasma disruptions and VDEs. This paper summarizes results of transient electromagnetic analysis using Opera 3d in support of the design activities for ITER diagnostic EPP. A complete distribution of disruption loads on the Diagnostic First Walls (DFWs). Diagnostic Shield Modules (DSMs) and the EPP structure, as well as impact on the system design integration duemore » to electrical contact among various EPP structural components are discussed.« less
Huh, Dongeun; Fujioka, Hideki; Tung, Yi-Chung; Futai, Nobuyuki; Paine, Robert; Grotberg, James B; Takayama, Shuichi
2007-11-27
We describe a microfabricated airway system integrated with computerized air-liquid two-phase microfluidics that enables on-chip engineering of human airway epithelia and precise reproduction of physiologic or pathologic liquid plug flows found in the respiratory system. Using this device, we demonstrate cellular-level lung injury under flow conditions that cause symptoms characteristic of a wide range of pulmonary diseases. Specifically, propagation and rupture of liquid plugs that simulate surfactant-deficient reopening of closed airways lead to significant injury of small airway epithelial cells by generating deleterious fluid mechanical stresses. We also show that the explosive pressure waves produced by plug rupture enable detection of the mechanical cellular injury as crackling sounds.
Passalacqua, Matthew; Lie, Kevin T; Yarmohammadi, Hooman
2012-01-01
A 3-year-old boy, who presented with progressive cyanosis and hypoxia, was diagnosed with a large congenital extrahepatic portosystemic shunt, interrupted IVC with azygos continuation, and multiple congenital anomalies. Traditionally open and laparoscopic surgical techniques have been used to treat this malformation. Endovascular repair using a 16-mm Amplatzer vascular plug (AGA Medical Corporation, Golden Valley, Minnesota, USA) was used to occlude the shunt. Immediate post-placement venography demonstrated cessation of flow within the shunt and increased portal venous flow. The patient's hypoxia and cyanosis decreased significantly, and he was discharged on the 5th post-procedure day in stable clinical condition. Three months follow-up evaluation demonstrated the vascular plug in place, unchanged in position.
Vowell, Kennison L.
1987-01-01
A closure for an inclined duct having an open upper end and defining downwardly extending passageway. The closure includes a cap for sealing engagement with the open upper end of the duct. Associated with the cap are an array of vertically aligned plug members, each of which has a cross-sectional area substantially conforming to the cross-sectional area of the passageway at least adjacent the upper end of the passageway. The plug members are interconnected in a manner to provide for free movement only in the plane in which the duct is inclined. The uppermost plug member is attached to the cap means and the cap means is in turn connected to a hoist means which is located directly over the open end of the duct.
Abrupt tectonics and rapid slab detachment with grain damage
Bercovici, David; Schubert, Gerald; Ricard, Yanick
2015-01-01
A simple model for necking and detachment of subducting slabs is developed to include the coupling between grain-sensitive rheology and grain-size evolution with damage. Necking is triggered by thickened buoyant crust entrained into a subduction zone, in which case grain damage accelerates necking and allows for relatively rapid slab detachment, i.e., within 1 My, depending on the size of the crustal plug. Thick continental crustal plugs can cause rapid necking while smaller plugs characteristic of ocean plateaux cause slower necking; oceanic lithosphere with normal or slightly thickened crust subducts without necking. The model potentially explains how large plateaux or continental crust drawn into subduction zones can cause slab loss and rapid changes in plate motion and/or induce abrupt continental rebound. PMID:25605890
Abrupt tectonics and rapid slab detachment with grain damage.
Bercovici, David; Schubert, Gerald; Ricard, Yanick
2015-02-03
A simple model for necking and detachment of subducting slabs is developed to include the coupling between grain-sensitive rheology and grain-size evolution with damage. Necking is triggered by thickened buoyant crust entrained into a subduction zone, in which case grain damage accelerates necking and allows for relatively rapid slab detachment, i.e., within 1 My, depending on the size of the crustal plug. Thick continental crustal plugs can cause rapid necking while smaller plugs characteristic of ocean plateaux cause slower necking; oceanic lithosphere with normal or slightly thickened crust subducts without necking. The model potentially explains how large plateaux or continental crust drawn into subduction zones can cause slab loss and rapid changes in plate motion and/or induce abrupt continental rebound.
Volumetric neuroimage analysis extensions for the MIPAV software package.
Bazin, Pierre-Louis; Cuzzocreo, Jennifer L; Yassa, Michael A; Gandler, William; McAuliffe, Matthew J; Bassett, Susan S; Pham, Dzung L
2007-09-15
We describe a new collection of publicly available software tools for performing quantitative neuroimage analysis. The tools perform semi-automatic brain extraction, tissue classification, Talairach alignment, and atlas-based measurements within a user-friendly graphical environment. They are implemented as plug-ins for MIPAV, a freely available medical image processing software package from the National Institutes of Health. Because the plug-ins and MIPAV are implemented in Java, both can be utilized on nearly any operating system platform. In addition to the software plug-ins, we have also released a digital version of the Talairach atlas that can be used to perform regional volumetric analyses. Several studies are conducted applying the new tools to simulated and real neuroimaging data sets.
Disastrous Portal Vein Embolization Turned into a Successful Intervention
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dobrocky, Tomas, E-mail: tomas.dobrocky@insel.ch; Kettenbach, Joachim, E-mail: joachim.kettenbach@stpoelten.lknoe.at; Lopez-Benitez, Ruben, E-mail: Ruben.lopez@insel.ch
Portal vein embolization (PVE) may be performed before hemihepatectomy to increase the volume of future liver remnant (FLR) and to reduce the risk of postoperative liver insufficiency. We report the case of a 71-year-old patient with hilar cholangiocarcinoma undergoing PVE with access from the right portal vein using a mixture of n-butyl-2-cyanoacrylate and ethiodized oil. During the procedure, nontarget embolization of the left portal vein occurred. An aspiration maneuver of the polymerized plug failed; however, the embolus obstructing portal venous flow in the FLR was successfully relocated into the right portal vein while carefully bypassing the plug with a balloonmore » catheter, inflating the balloon, and pulling the plug into the main right portal vein.« less
Macromolecular crystal growing system
NASA Technical Reports Server (NTRS)
Snyder, Robert S. (Inventor); Herren, Blair J. (Inventor); Carter, Daniel C. (Inventor); Yost, Vaughn H. (Inventor); Bugg, Charles E. (Inventor); Delucas, Lawrence J. (Inventor); Suddath, Fred L. (Inventor)
1991-01-01
A macromolecular crystal growing system especially designed for growing crystals in the low gravity of space as well as the gravity of earth includes at least one tray assembly, a carrier assembly which receives the tray, and a refrigeration-incubation module in which the carrier assembly is received. The tray assembly includes a plurality of sealed chambers with a plastic syringe and a plug means for the double tip of the syringe provided therein. Ganging mechanisms operate the syringes and plugs simultaneously in a precise and smooth operation. Preferably, the tray assemblies are mounted on ball bearing slides for smooth operation in inserting and removing the tray assemblies into the carrier assembly. The plugging mechanism also includes a loading control mechanism. A mechanism for leaving a syringe unplugged is also provided.
NASA Technical Reports Server (NTRS)
Mann, C. W. (Inventor)
1984-01-01
A device used in the optical alignment of machinery to maintain a measuring scale in the proper position for optical readings to be taken is described. The device consists of a block containing a notch in the shape of an inverted ""v'' and a rotatable plug positioned over the centerline of notch. The block is placed on the object to be aligned, the notch allows the block to be securely placed upon flat or curved surfaces. A weighted measuring scale is inserted through plug so that it contacts the object to be aligned. The scale and plug combination can be rotated so that the scale faces an optical aligning instrument. The instrument is then used in conjunction with the scale to measure the distance of the machinery from a reference plane.
Li, Liang; Mustafi, Debarshi; Fu, Qiang; Tereshko, Valentina; Chen, Delai L.; Tice, Joshua D.; Ismagilov, Rustem F.
2006-01-01
High-throughput screening and optimization experiments are critical to a number of fields, including chemistry and structural and molecular biology. The separation of these two steps may introduce false negatives and a time delay between initial screening and subsequent optimization. Although a hybrid method combining both steps may address these problems, miniaturization is required to minimize sample consumption. This article reports a “hybrid” droplet-based microfluidic approach that combines the steps of screening and optimization into one simple experiment and uses nanoliter-sized plugs to minimize sample consumption. Many distinct reagents were sequentially introduced as ≈140-nl plugs into a microfluidic device and combined with a substrate and a diluting buffer. Tests were conducted in ≈10-nl plugs containing different concentrations of a reagent. Methods were developed to form plugs of controlled concentrations, index concentrations, and incubate thousands of plugs inexpensively and without evaporation. To validate the hybrid method and demonstrate its applicability to challenging problems, crystallization of model membrane proteins and handling of solutions of detergents and viscous precipitants were demonstrated. By using 10 μl of protein solution, ≈1,300 crystallization trials were set up within 20 min by one researcher. This method was compatible with growth, manipulation, and extraction of high-quality crystals of membrane proteins, demonstrated by obtaining high-resolution diffraction images and solving a crystal structure. This robust method requires inexpensive equipment and supplies, should be especially suitable for use in individual laboratories, and could find applications in a number of areas that require chemical, biochemical, and biological screening and optimization. PMID:17159147
Bubble-free on-chip continuous-flow polymerase chain reaction: concept and application.
Wu, Wenming; Kang, Kyung-Tae; Lee, Nae Yoon
2011-06-07
Bubble formation inside a microscale channel is a significant problem in general microfluidic experiments. The problem becomes especially crucial when performing a polymerase chain reaction (PCR) on a chip which is subject to repetitive temperature changes. In this paper, we propose a bubble-free sample injection scheme applicable for continuous-flow PCR inside a glass/PDMS hybrid microfluidic chip, and attempt to provide a theoretical basis concerning bubble formation and elimination. Highly viscous paraffin oil plugs are employed in both the anterior and posterior ends of a sample plug, completely encapsulating the sample and eliminating possible nucleation sites for bubbles. In this way, internal channel pressure is increased, and vaporization of the sample is prevented, suppressing bubble formation. Use of an oil plug in the posterior end of the sample plug aids in maintaining a stable flow of a sample at a constant rate inside a heated microchannel throughout the entire reaction, as compared to using an air plug. By adopting the proposed sample injection scheme, we demonstrate various practical applications. On-chip continuous-flow PCR is performed employing genomic DNA extracted from a clinical single hair root sample, and its D1S80 locus is successfully amplified. Also, chip reusability is assessed using a plasmid vector. A single chip is used up to 10 times repeatedly without being destroyed, maintaining almost equal intensities of the resulting amplicons after each run, ensuring the reliability and reproducibility of the proposed sample injection scheme. In addition, the use of a commercially-available and highly cost-effective hot plate as a potential candidate for the heating source is investigated.
River restoration strategies in channelized, low-gradient landscapes of West Tennessee, USA
Smith, D.P.; Diehl, T.H.; Turrini-Smith, L. A.; Maas-Baldwin, J.; Croyle, Z.
2009-01-01
West Tennessee has a complex history of watershed disturbance, including agricultural erosion, channelization, accelerated valley sedimentation, and the removal and reestablishment of beaver. Watershed management has evolved from fl oodplain drainage via pervasive channelization to include local drainage canal maintenance and local river restoration. Many unmaintained canals are undergoing excessive aggradation and complex channel evolution driven by upland erosion and low valley gradient. The locus of aggradation in fully occluded canals (valley plugs) moves up-valley as sediment continues to accumulate in the backwater behind the plug. Valley plugs that cause canal avulsion can lead to redevelopment of meandering channels in less disturbed areas of the fl oodplain, in a process of passive self-restoration. Some valley plugs have brought restored fl oodplain function, reoccupation of extant historic river channels, and formation of a "sediment shadow" that protects downstream reaches from excess sedimentation. Despite the presence of numerous opportunities, there is presently no mechanism for including valley plugs in mitigation projects. In 1997 a survey of 14 reference reach cross sections documented relations between drainage area and bankfull geometry of relatively unmodified streams in West Tennessee. Reassessment of seven of those sites in 2007 showed that one had been dammed by beaver and that two sites could not be analyzed further because of signifi cant vertical or lateral instability. In contrast to other regions of North America, the results suggest that stream channels in this region fl ood more frequently than once each year, and can remain out of banks for several weeks each year. ?? 2009 Geological Society of America.
A novel, intelligent, pressure-sensing colostomy plug for reducing fecal leakage.
Chen, Fei; Li, Zhi-Chao; Li, Qiang; Liang, Fei-Xue; Guo, Xiong-Bo; Huang, Zong-Hai
2015-06-01
This study aims to describe and report the effectiveness of a novel, pressure-sensing colostomy plug for reducing fecal leakage. Nine miniature Tibetan pigs, aged 6-8 months, were given colostomies and divided into three groups (n = 3 each group). A novel pressure-sensing colostomy plug was placed in each pig and set to indicate when intestinal pressures of either 5, 10, or 15 mm Hg, respectively, were reached. When the pressure thresholds were reached, the animals' bowels were examined for the presence of stool and/or stomal leakage, and the data were recorded at weeks 1, 4, and 8 after surgery. The colostomy plug calibrated to 15 mm Hg pressure demonstrated the greatest accuracy in predicting the presence of stool in the bowels of study animals, averaging >90% sensitivity. In general, the sensitivity for predicting the presence of stool did not vary significantly over time, though there was a slight increase in accuracy in the 5 mm Hg group at later time-points. The sensitivity for predicting stool in the bowel did not change significantly over time in any of the three groups. Stomal leakage was found to be inversely proportional to the pressure-sensor setting, in that the 15 mm Hg group exhibited the greatest amount of leakage. This difference, however, was found to be significant only at week 1 postsurgery. The intelligent, pressure-sensing colostomy plug was able to accurately predict the presence of stool in the bowel and maintain continence, allowing negligible leakage. Copyright © 2015 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.