Science.gov

Sample records for pneumatic capsule pipeline

  1. Capsule injection system for a hydraulic capsule pipelining system

    DOEpatents

    Liu, Henry

    1982-01-01

    An injection system for injecting capsules into a hydraulic capsule pipelining system, the pipelining system comprising a pipeline adapted for flow of a carrier liquid therethrough, and capsules adapted to be transported through the pipeline by the carrier liquid flowing through the pipeline. The injection system comprises a reservoir of carrier liquid, the pipeline extending within the reservoir and extending downstream out of the reservoir, and a magazine in the reservoir for holding capsules in a series, one above another, for injection into the pipeline in the reservoir. The magazine has a lower end in communication with the pipeline in the reservoir for delivery of capsules from the magazine into the pipeline.

  2. Intracranial pressure monitoring system with pneumatic capsule sensor

    NASA Astrophysics Data System (ADS)

    Juniewicz, Henryk M.; Werszko, Miroslaw

    1995-06-01

    In the paper, a computer system for measurement, visualization and analysis of intracranial pressure (ICP), medium arterial pressure and cerebral perfusion pressure in one, two, three or four patients simultaneously has been presented. A structure of pneumatic compensatory sensor for intracranial pressure, and a stand for static properties of the sensors testing has been discussed. Conclusions resulting from the period of using the monitoring system with ICP pneumatic sensors have been formulated.

  3. Finite-Element Modeling of Electrostatic Sensors for the Flow Measurement of Particles in Pneumatic Pipelines

    SciTech Connect

    Krabicka, J.; Yan, Y.

    2009-08-15

    Electrostatic sensors are used in certain industries for the flow measurement of pneumatically conveyed solids. However, despite various advances that have been made in recent years, relatively little information is known about the exact nature of the electrostatic charge induced onto the sensor electrode due to moving particles, which is dependent on electrode geometry, particle distribution, and particle velocity. This paper presents a novel approach to the study of the charge induced onto electrostatic sensors based on fitting a Lorentzian curve to the results of a finite-element model of the electrostatic sensor and pipeline. The modeling method is validated by comparing the modeling results of a nonintrusive circular electrode with an established analytical solution. The modeling results are used for in-depth analysis and informed design of a particular sensor configuration.

  4. Capsule Pipeline Research Center. 3-year Progress report, September 1, 1993--August 31, 1994

    SciTech Connect

    Not Available

    1994-04-01

    The Capsule Pipeline Research Center is devoted to performing research in capsule pipelines so that this emerging technology can be developed for early use to transport solids including coal, grain, other agricultural products, solid wastes, etc. Important research findings and accomplishments during the first-three years include: success in making durable binderless coal logs by compaction, success in underwater extrusion of binderless coal logs, success in compacting and extruding coal logs with less than 3% hydrophobic binder at room temperature, improvement in the injection system and the pump-bypass scheme, advancement in the state-of-the-art of predicting the energy loss (pressure drop) along both stationary and moving capsules, demonstrated the effectiveness of using polymer for drag reduction in CLP, demonstrated the influence of zeta potential on coal log fabrication, improved understanding of the water absorption properties of coal logs, better understanding of the mechanism of coal log abrasion (wear), completed a detailed economic evaluation of the CLP technology and compared coal transportation cost by CLP to that by rail, truck and slurry pipelines, and completion of several areas of legal research. The Center also conducted important technology transfer activities including workshops, work sessions, company seminars, involvement of companies in CLP research, issuance of newsletters, completion of a video tape on CLP, and presentation of research findings at numerous national and international meetings.

  5. Quantitative characterization of pulverized coal and biomass-coal blends in pneumatic conveying pipelines using electrostatic sensor arrays and data fusion techniques

    NASA Astrophysics Data System (ADS)

    Qian, Xiangchen; Yan, Yong; Shao, Jiaqing; Wang, Lijuan; Zhou, Hao; Wang, Chao

    2012-08-01

    Quantitative data about the dynamic behaviour of pulverized coal and biomass-coal blends in fuel injection pipelines allow power plant operators to detect variations in fuel supply and oscillations in the flow at an early stage, enable them to balance fuel distribution between fuel feeding pipes and ultimately to achieve higher combustion efficiency and lower greenhouse gas emissions. Electrostatic sensor arrays and data fusion algorithms are combined to provide a non-intrusive solution to the measurement of fuel particle velocity, relative solid concentration and flow stability under pneumatic conveying conditions. Electrostatic sensor arrays with circular and arc-shaped electrodes are integrated in the same sensing head to measure ‘averaged’ and ‘localized’ characteristics of pulverized fuel flow. Data fusion techniques are applied to optimize and integrate the results from the sensor arrays. Experimental tests were conducted on the horizontal section of a 150 mm bore pneumatic conveyor circulating pulverized coal and sawdust under various flow conditions. Test results suggest that pure coal particles travel faster and carry more electrostatic charge than biomass-coal blends. As more biomass particles are added to the flow, the overall velocity of the flow reduces, the electrostatic charge level on particles decreases and the flow becomes less stable compared to the pure coal flow.

  6. Craniocervical Pneumatization

    PubMed Central

    Quigley, Alan James; Shannon, Helen

    2013-01-01

    Craniocervical bony pneumatization is a rare finding, with limited numbers of cases reported in the literature. It is thought to be linked to Eustachian tube dysfunction and a ball valve mechanism, and has a link with recurrent Valsalva maneuvers. We report a case of pneumatization of the occiput, atlas (C1) and axis (C2) in a patient with extensive ENT (Ear, Nose and Throat) surgical history who presented following a fall. Plain film, CT and MRI images are presented. PMID:24421950

  7. AN ELECTROMAGNETIC PNEUMO CAPSULE SYSTEM FOR CONVEYING MINERALS AND MINE WASTES

    SciTech Connect

    Henry Liu; Charles W. Lenau

    2005-03-01

    The purpose of this project is to investigate the technical and economic feasibility of using a new and advanced pneumatic capsule pipeline (PCP) system for transporting minerals and mine wastes. The new system is different from conventional PCPs in two main respects: (1) it uses linear induction motors (LIMs) instead of blowers (fans) at the inlet of the pipeline to drive (pump) the capsules and the air through the pipeline; and (2) the capsules in the PCP have steel wheels running on steel rails as opposed to capsules in conventional systems, which use wheels with rubber tires running inside a pipe without rail. The advantage of using LIM pump instead of blower is that the former is non-intrusive and hence does not block the passage of capsules, enabling the system to run continuously without having to make the capsules bypass the pump. This not only simplifies the system but also enables the system to achieve much larger cargo throughput than that of PCPs using blowers, and use of LIMs as booster pumps which enables the system to have any length or to be used for transporting cargoes over practically any distance, say even one thousand kilometers or miles. An advantage of using steel wheels rolling on steel rails instead of using rubber tires rolling inside a pipeline is that the rolling friction coefficient and hence the use of energy is greatly reduced from that of conventional PCP systems. Moreover, rails enable easy control of capsule motion, such as switching capsules to a branch line by using railroad switching equipment. The advanced PCP system studied under this project uses rectangular conduits instead of circular pipe, having cross-sectional areas of 1 m by 1 m approximately. The system can be used for various transportation distances, and it can transport up to 50 million tonnes (metric tons) of cargo annually--the throughput of the largest mines in the world. Both an aboveground and an underground system were investigated and compared. The technical

  8. Pneumatic stowing seals mines

    SciTech Connect

    Brezovec, D.

    1983-11-01

    A mechanized technique to seal abandoned mines has been used successfully to close 13 openings at Duquesne Light Co.'s mined-out Warwick No. 2 mine, near Greensboro, Pa. The mechanized system, which uses a pneumatic stower and crushed limestone, closed the entries more economically and in less time than it would have taken to install traditional concrete block stopping and clay plug seals, according to John C. Draper. Draper, a mining engineer with Duquesne Light's coal department, was in charge of installing the Warwick seals in a Bureau of Mines-sponsored field test on the pneumatic sealing technique. The lowest estimated cost for installing conventional stopping and plug closures for the 13 Warwick openings was $225,000, says Draper, while the openings were closed using the mechanized system for $245,000. Draper says the newer stopping cost more in the instance because work was stopped often to gather information for the experiment. The experimental closures were installed in 38 days. The job would have taken at least 149 days if traditional closures were being installed, Draper say. To install a traditional concrete block/clay plug closure, the mine opening must be cleaned thoroughly and the roof must be supported for some 3 ft from the outside. Then a solid wall or stopping must be built 25 ft from the surface and the entry must be packed with clay to the surface. Much of this job requires workers to remain underground. In pneumatic stowing, 1 1/2-in. crushed limestone with fines is conveyed through a pipeline and into the mine opening under low air pressure. Watertight seals can be installed by blowing about 10 ft of rock into the opening against the top to act as roof support. Safety posts are installed and about 10 or 15 ft of mine entry is cleaned. About 2 in. of raw cement or bentonite is placed on the floor and limestone mixed with dry cement or bentonite is blown into the opening.

  9. Pneumatic Valve Operated by Multiplex Pneumatic Transmission

    NASA Astrophysics Data System (ADS)

    Nishioka, Yasutaka; Suzumori, Koichi; Kanda, Takefumi; Wakimoto, Shuichi

    A pneumatic system has several advantages, which are cheapness, lightweight, and reliability to human and environment. These advantages are adapted to some research areas, such as industrial lines, medical and nursing cares, and rehabilitation tools. However, the pneumatic system needs several devices; compressor, air tube, and control valve. This research aim to downsize pneumatic system. In this paper, a new method of multiplex pneumatic transmission for multi-pneumatic servo system is proposed. The valve for this system consists of two vibrators supported by springs, which was designed with simple and cheap structure. The working principle of the valve is vibrators resonance from multiplex pneumatic transmission and it is possible to work as ON/OFF valves without electric wire. Dynamic simulation was used to confirm the working principle of the resonance driving system. A prototype device confirming the principle was designed and developed based on the simulation. The experiments show that this new control system works very well to control two separated valves through single pneumatic tube.

  10. Rotary pneumatic valve

    DOEpatents

    Hardee, Harry C.

    1991-01-01

    A rotary pneumatic valve which is thrust balanced and the pneumatic pressure developed produces only radial loads on the valve cylinder producing negligible resistance and thus minimal torque on the bearings of the valve. The valve is multiplexed such that at least two complete switching cycles occur for each revolution of the cylinder spindle.

  11. Basic Pneumatics. Instructor's Guide.

    ERIC Educational Resources Information Center

    Fessehaye, Michael

    This instructor's guide is designed for use by industrial vocational teachers in teaching a course on basic pneumatics. Covered in the individual units are the following topics: an introduction to pneumatics (including the operation of a service station hoist); fundamentals and physical laws; air compressors (positive displacement compressors;…

  12. Pneumatic soil removal tool

    DOEpatents

    Neuhaus, John E.

    1992-01-01

    A soil removal tool is provided for removing radioactive soil, rock and other debris from the bottom of an excavation, while permitting the operator to be located outside of a containment for that excavation. The tool includes a fixed jaw, secured to one end of an elongate pipe, which cooperates with a movable jaw pivotably mounted on the pipe. Movement of the movable jaw is controlled by a pneumatic cylinder mounted on the pipe. The actuator rod of the pneumatic cylinder is connected to a collar which is slidably mounted on the pipe and forms part of the pivotable mounting assembly for the movable jaw. Air is supplied to the pneumatic cylinder through a handle connected to the pipe, under the control of an actuator valve mounted on the handle, to provide movement of the movable jaw.

  13. Pneumatic soil removal tool

    DOEpatents

    Neuhaus, J.E.

    1992-10-13

    A soil removal tool is provided for removing radioactive soil, rock and other debris from the bottom of an excavation, while permitting the operator to be located outside of a containment for that excavation. The tool includes a fixed jaw, secured to one end of an elongate pipe, which cooperates with a movable jaw pivotably mounted on the pipe. Movement of the movable jaw is controlled by a pneumatic cylinder mounted on the pipe. The actuator rod of the pneumatic cylinder is connected to a collar which is slidably mounted on the pipe and forms part of the pivotable mounting assembly for the movable jaw. Air is supplied to the pneumatic cylinder through a handle connected to the pipe, under the control of an actuator valve mounted on the handle, to provide movement of the movable jaw. 3 figs.

  14. Pneumatic squirming robot based on flexible pneumatic actuator

    NASA Astrophysics Data System (ADS)

    Yang, Qinghua; Zhang, Libin; Bao, Guanjun; Ruan, Jian

    2005-12-01

    The design of a kind of pneumatic squirming robot is presented. It is based on the use of flexible pneumatic actuator. The flexible pneumatic actuator was made of caoutchouc. Its working principle is described. The structure, working principle, pneumatic and electrical control system of the pneumatic squirming robot are designed. All of the actuator's driving and squirming parts are composed of pneumatic elements. The vacuum osculums, which act as feet, are connected to the flexible pneumatic actuator. When the vacuum pumps operate, vacuum will be produced in the corresponding osculums, which can adsorb on the contacting surface and orient the robot. The actuator, operating under air pressure, drives the robot. By controlling the vacuum pumps and the actuator, straight and bending squirming of this robot can be obtained.

  15. Pneumatic stowing seals mines

    SciTech Connect

    Brezovec, D.

    1983-11-01

    A pneumatic stowing technique has been used in the US to seal entries to abandoned mines. Limestone mixed with dry cement or bentonite is blown into the opening. Sealing can be accomplished in much less time than with traditional concrete block/clay plug methods.

  16. Pneumatic osteoarthritis knee brace.

    PubMed

    Stamenović, Dimitrije; Kojić, Milos; Stojanović, Boban; Hunter, David

    2009-04-01

    Knee osteoarthritis is a chronic disease that necessitates long term therapeutic intervention. Biomechanical studies have demonstrated an improvement in the external adduction moment with application of a valgus knee brace. Despite being both efficacious and safe, due to their rigid frame and bulkiness, current designs of knee braces create discomfort and difficulties to patients during prolonged periods of application. Here we propose a novel design of a light osteoarthritis knee brace, which is made of soft conforming materials. Our design relies on a pneumatic leverage system, which, when pressurized, reduces the excessive loads predominantly affecting the medial compartment of the knee and eventually reverses the malalignment. Using a finite-element analysis, we show that with a moderate level of applied pressure, this pneumatic brace can, in theory, counterbalance a greater fraction of external adduction moment than the currently existing braces.

  17. Pneumatic conveyance apparatus and process

    DOEpatents

    Heckendorn, Frank M.; Matzolf, Athneal D.; Hera, Kevin R.

    2010-05-04

    A pneumatic nozzle capable of removing dry solid debris, liquids, and mixtures of solid and liquid waste is provided. The pneumatic nozzle uses a pressurized gas stream to push materials through the nozzle. The force of a pressurized gas stream provides a partial vacuum to allow material to be introduced into an opening of a nozzle via a slight suction force. Thereafter, individual particles and materials introduced into the pneumatic nozzle are pushed by a stream of pressurized gas through the nozzle.

  18. Pneumatic Pellet-Transporting System

    NASA Technical Reports Server (NTRS)

    Wood, George; Pugsley, Robert A.

    1992-01-01

    Pneumatic system transports food pellets to confined animals. Flow of air into venturi assembly entrains round pellets, drawing them from reservoir into venturi for transport by airflow. Pneumatic pellet-transporting system includes venturi assembly, which creates flow of air that draws pellets into system.

  19. Pneumatization of the sphenoid sinus.

    PubMed

    Terra, E R; Guedes, F R; Manzi, F R; Bóscolo, F N

    2006-01-01

    This paper describes a case of pneumatization of the sphenoid sinus in the pterygoid process and greater wing of the sphenoid bone, observed on a panoramic radiograph. Conventional radiographs and computerized tomography in axial and coronal sections confirmed the presence of the pneumatization of these structures.

  20. Rigidified pneumatic composites

    NASA Astrophysics Data System (ADS)

    van Dessel, Steven

    2000-10-01

    The overall objective of the research presented in this dissertation was to address global issues of adequate housing for all and the need for more sustainable human settlement. In order to address these, the emerging technology of rigidified pneumatic composites was investigated. Rigidified pneumatic composites (RPC) are defined as thin flexible membrane structures that are pneumatically deployed. After deployment, these structures harden due to chemical or physical change of the membrane. Because of this change, these structures do no longer require pneumatic pressure to maintain their shape. For the first time, a systematic listing of the various means available to develop polymeric materials useful in RPC technology is presented. With the aim to reduce the cost of RPC structures, a new material was proposed, developed, and evaluated. This material involved the formation of a semi-interpenetrating polymer network based on poly vinyl chloride and an acrylate based reactive plasticizer. The economical and environmental performances of RPC structures using this new material were assessed by means of a case study. In this study, the performance of RPC technology was compared with that of a typical wood light frame structure in the application of a small single-family house. The study indicated that the cost of ownership in present day value for the RPC structure was approximately 33% less than the cost of a comparable wood light frame structure. The study also indicated that significant environmental benefits exist with the use of RPC structures. It was found that the RPC structure used significantly less resources compared to the wood light frame structure. About 3.5 times less materials coming from non-renewable fossil resources, about 2.5 times less materials coming from trees, and about 19 times less materials coming from inorganic resources was used in the RPC structure relative to the wood light frame structure. The study concluded with pointing out various

  1. Pneumatic energy storage

    SciTech Connect

    Flowers, D.

    1995-09-19

    An essential component to hybrid electric and electric vehicles is energy storage. A power assist device could also be important to many vehicle applications. This discussion focuses on the use of compressed gas as a system for energy storage and power in vehicle systems. Three possible vehicular applications for which these system could be used are discussed in this paper. These applications are pneumatically driven vehicles, series hybrid electric vehicles, and power boost for electric and conventional vehicles. One option for a compressed gas system is as a long duration power output device for purely pneumatic and hybrid cars. This system must provide enough power and energy to drive under normal conditions for a specified time or distance. The energy storage system for this use has the requirement that it will be highly efficient, compact, and have low mass. Use of a compressed gas energy storage as a short duration, high power output system for conventional motor vehicles could reduce engine size or reduce transient emissions. For electric vehicles this kind of system could lengthen battery life by providing battery load leveling during accelerations. The system requirements for this application are that it be compact and have low mass. The efficiency of the system is a secondary consideration in this application.

  2. Origin of postcranial skeletal pneumaticity in dinosaurs.

    PubMed

    Wedel, Mathew J

    2006-06-01

    The sauropodomorph Thecodontosaurus caducus and theropod Coelophysis bauri are the earliest known dinosaurs with postcranial skeletal pneumaticity. In both taxa, postcranial pneumatic features are confined to the cervical vertebrae. This distribution of pneumaticity in the skeleton is most consistent with pneumatization by diverticula of cervical air sacs similar to those of birds. Other hypotheses, including pneumatization by diverticula of the lungs, larynx and trachea, or cranial air spaces, are less well-supported.

  3. Ultrahigh speed en face OCT capsule for endoscopic imaging

    PubMed Central

    Liang, Kaicheng; Traverso, Giovanni; Lee, Hsiang-Chieh; Ahsen, Osman Oguz; Wang, Zhao; Potsaid, Benjamin; Giacomelli, Michael; Jayaraman, Vijaysekhar; Barman, Ross; Cable, Alex; Mashimo, Hiroshi; Langer, Robert; Fujimoto, James G.

    2015-01-01

    Depth resolved and en face OCT visualization in vivo may have important clinical applications in endoscopy. We demonstrate a high speed, two-dimensional (2D) distal scanning capsule with a micromotor for fast rotary scanning and a pneumatic actuator for precision longitudinal scanning. Longitudinal position measurement and image registration were performed by optical tracking of the pneumatic scanner. The 2D scanning device enables high resolution imaging over a small field of view and is suitable for OCT as well as other scanning microscopies. Large field of view imaging for screening or surveillance applications can also be achieved by proximally pulling back or advancing the capsule while scanning the distal high-speed micromotor. Circumferential en face OCT was demonstrated in living swine at 250 Hz frame rate and 1 MHz A-scan rate using a MEMS tunable VCSEL light source at 1300 nm. Cross-sectional and en face OCT views of the upper and lower gastrointestinal tract were generated with precision distal pneumatic longitudinal actuation as well as proximal manual longitudinal actuation. These devices could enable clinical studies either as an adjunct to endoscopy, attached to an endoscope, or as a swallowed tethered capsule for non-endoscopic imaging without sedation. The combination of ultrahigh speed imaging and distal scanning capsule technology could enable both screening and surveillance applications. PMID:25909001

  4. Temperature Capsule

    NASA Technical Reports Server (NTRS)

    1992-01-01

    An ingestible mini-thermometer capable of measuring and relaying internal body temperatures is marketed by Human Technologies, Inc. The CorTemp system, developed by Goddard Space Flight Center and Applied Physics Lab, incorporates space technologies, among them telemetry and microminiaturized circuit, sensor and battery technologies. The capsule is ingested and continually monitors temperature with a vibrating quartz crystal sensor, which telemeters signals to a recorder, where data is displayed and stored. The system is very accurate, and because it does not require wires, allows patients to be monitored in everyday situations. The industrial variant (CSC-100) has wide utility in commercial applications.

  5. Instrumented Pneumatic-Impact Tester

    NASA Technical Reports Server (NTRS)

    Shelley, Richard M.; Armendariz, Norman

    1993-01-01

    Pneumatic-impact tester is small pressure chamber equipped with specimen holder and optical port. Device designed to test susceptibility of polymeric material to ignition by "pneumatic impact" in high-pressure gaseous oxygen. Used to determine differences among susceptibilities to ignition of different materials and of different batches of nominally same material proposed for use in systems containing pressurized oxygen. Also used to show characteristics of ignition and combustion.

  6. Spacecraft -- Capsule Separation (Animation)

    NASA Technical Reports Server (NTRS)

    2005-01-01

    [figure removed for brevity, see original site] Click on the image for Spacecraft -- Capsule Separation animation

    This animation shows the return capsule separating from the Stardust spacecraft.

  7. Development of the prototype pneumatic transfer system for ITER neutron activation systema)

    NASA Astrophysics Data System (ADS)

    Cheon, M. S.; Seon, C. R.; Pak, S.; Lee, H. G.; Bertalot, L.

    2012-10-01

    The neutron activation system (NAS) measures neutron fluence at the first wall and the total neutron flux from the ITER plasma, providing evaluation of the fusion power for all operational phases. The pneumatic transfer system (PTS) is one of the key components of the NAS for the proper operation of the system, playing a role of transferring encapsulated samples between the capsule loading machine, irradiation stations, counting stations, and disposal bin. For the validation and the optimization of the design, a prototype of the PTS was developed and capsule transfer tests were performed with the developed system.

  8. 49 CFR 236.590 - Pneumatic apparatus.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 4 2011-10-01 2011-10-01 false Pneumatic apparatus. 236.590 Section 236.590..., Train Control and Cab Signal Systems Inspection and Tests; Locomotive § 236.590 Pneumatic apparatus. Automatic train stop, train control, or cab signal pneumatic apparatus shall be inspected, cleaned, and...

  9. 49 CFR 236.590 - Pneumatic apparatus.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Pneumatic apparatus. 236.590 Section 236.590..., Train Control and Cab Signal Systems Inspection and Tests; Locomotive § 236.590 Pneumatic apparatus. Automatic train stop, train control, or cab signal pneumatic apparatus shall be inspected, cleaned, and...

  10. Pneumatic Spoiler Controls Airfoil Lift

    NASA Technical Reports Server (NTRS)

    Hunter, D.; Krauss, T.

    1991-01-01

    Air ejection from leading edge of airfoil used for controlled decrease of lift. Pneumatic-spoiler principle developed for equalizing lift on helicopter rotor blades. Also used to enhance aerodynamic control of short-fuselage or rudderless aircraft such as "flying-wing" airplanes. Leading-edge injection increases maneuverability of such high-performance fixed-wing aircraft as fighters.

  11. Pneumatic gap sensor and method

    DOEpatents

    Bagdal, Karl T.; King, Edward L.; Follstaedt, Donald W.

    1992-01-01

    An apparatus and method for monitoring and maintaining a predetermined width in the gap between a casting nozzle and a casting wheel, wherein the gap is monitored by means of at least one pneumatic gap sensor. The pneumatic gap sensor is mounted on the casting nozzle in proximity to the casting surface and is connected by means of a tube to a regulator and a transducer. The regulator provides a flow of gas through a restictor to the pneumatic gap sensor, and the transducer translates the changes in the gas pressure caused by the proximity of the casting wheel to the pneumatic gap sensor outlet into a signal intelligible to a control device. The relative positions of the casting nozzle and casting wheel can thereby be selectively adjusted to continually maintain a predetermined distance between their adjacent surfaces. The apparatus and method enables accurate monitoring of the actual casting gap in a simple and reliable manner resistant to the extreme temperatures and otherwise hostile casting environment.

  12. Pneumatic gap sensor and method

    DOEpatents

    Bagdal, K.T.; King, E.L.; Follstaedt, D.W.

    1992-03-03

    An apparatus and method for monitoring and maintaining a predetermined width in the gap between a casting nozzle and a casting wheel, wherein the gap is monitored by means of at least one pneumatic gap sensor. The pneumatic gap sensor is mounted on the casting nozzle in proximity to the casting surface and is connected by means of a tube to a regulator and a transducer. The regulator provides a flow of gas through a restictor to the pneumatic gap sensor, and the transducer translates the changes in the gas pressure caused by the proximity of the casting wheel to the pneumatic gap sensor outlet into a signal intelligible to a control device. The relative positions of the casting nozzle and casting wheel can thereby be selectively adjusted to continually maintain a predetermined distance between their adjacent surfaces. The apparatus and method enables accurate monitoring of the actual casting gap in a simple and reliable manner resistant to the extreme temperatures and otherwise hostile casting environment. 6 figs.

  13. Sweat collection capsule

    NASA Technical Reports Server (NTRS)

    Delaplaine, R. W.; Greenleaf, J. E.

    1979-01-01

    Capsule, with filter paper insert, is used to collect sweat for rate monitoring, chromatographic analysis, or active sweat gland location within specified area. Construction of capsule allows change of inserts while device remains strapped in place.

  14. Stability of Betaine Capsules

    PubMed Central

    Boily, Stéphanie; Forest, Jean-Marc

    2013-01-01

    Betaine is used to treat homocystinuria and is not available in Canada as a formulated drug. In order to facilitate the administration of this compound to patients, a capsule formulation and an evaluation of its stability were required. Capsule formulations of betaine were developed (160 mg and 625 mg of betaine per capsule). As betaine has no chromophore, an HPLC-ELSD analytical method was also developed. The critical quality attributes of these formulations were evaluated (content assay, content uniformity, and dissolution) as well as their stability. Capsules with acceptable quality attributes were produced. These capsules remained stable for 1 year when stored in airtight containers at controlled room temperature. However, shelf life decreased dramatically in nonairtight containers at 30°C (3 months for the lactose-containing capsules of 160 mg and 6 months for the capsules of 625 mg). PMID:23862077

  15. Model for pneumatic pellet injection

    SciTech Connect

    Hogan, J.T.; Milora, S.L.; Schuresko, D.D.

    1983-07-01

    A hydrodynamic code has been developed to model the performance of pneumatic pellet injection systems. The code describes one dimensional, unsteady compressible gas dynamics, including gas friction and heat transfer to the walls in a system with variable area. The mass, momentum, and energy equations are solved with an iterated Lax-Wendroff scheme with additional numerical viscosity. The code is described and comparisons with experimental data are presented.

  16. Electric versus hydraulics versus pneumatics

    SciTech Connect

    Not Available

    1985-01-01

    This book presents a collection of papers from a conference which considered the advantages and disadvantages of electric, hydraulic and pneumatic drives and actuators. The volume follows on the success of the 1983 conference on electric and hydraulic drives. Topics considered include fork lift trucks - an ideal application for regenerative transmissions; a hybrid-electric power system with hydrostatic transmission; electrics and hydraulics on roadheader machinery; hydraulic, electrical, pneumatic control - which way to go. an electrically-powered servo to drive the two axes of a missile launching platform - pros and cons when compared with the traditional hydraulic solution; the encapsulation of a novel intrinsically safe displacement transducer; mobile cryogenic pumping systems; automation of a wood-turning machine, hydraulic or electric. The choice of a servo motor for a specific application; developments in the design and control of pneumatic linear actuators; compressed air purification for instrumentation in the high technology industries; trends in prime mover choice for powered hand tools; and choosing the drive system for the right application.

  17. A pneumatic transfer system for special form {sup 252}Cf

    SciTech Connect

    Gehrke, R.J.; Berry, S.M.; Grafwallner, E.G.; Hoggan, J.M.

    1996-09-01

    A pneumatic transfer system has been developed for use with series 100 Special Form {sup 252}Cf. It was developed to reduce the exposure to personnel handling sources of {sup 252}Cf with masses up to 150 {micro}g by permitting remotely activated two-way transfer between the storage container and the irradiation position. The pneumatic transfer system also permits transfers for reproducible repetitive irradiation periods. In addition to the storage container equipped with quick-release fittings, the transfer system consists of an irradiation station, a control box with momentary contact switches to activate the air-pressure control valves and indicators to identify the location of the source, and connecting air hose and electrical wire. A source of 20 psig air and 110 volt electrical power are required for operation of the transfer system which can be easily moved and set up by one individual in 5 to 10 minutes. Tests have shown that rarely does a source become lodged in the transfer tubing, but two methods have been developed to handle incomplete transfers of the {sup 252}Cf source. The first method consists of closing one air vent to allow a pressure impulse to propel the source to the opposite side. The second method applies to those {sup 252}Cf capsules with a threaded or tapped end to which a small ferromagnetic piece can be attached; an incompletely transferred source in the transfer tube can then be guided to a position of safety by surrounding the transfer tubing containing the capsule with a horseshoe magnet attached to the end of a long pole.

  18. Pipeline Expansions

    EIA Publications

    1999-01-01

    This appendix examines the nature and type of proposed pipeline projects announced or approved for construction during the next several years in the United States. It also includes those projects in Canada and Mexico that tie-in with the U.S. markets or projects.

  19. 21 CFR 878.5910 - Pneumatic tourniquet.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ...) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Therapeutic Devices § 878.5910 Pneumatic tourniquet... patient's limb and inflated to reduce or totally occlude circulation during surgery. (b)...

  20. 21 CFR 878.5910 - Pneumatic tourniquet.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ...) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Therapeutic Devices § 878.5910 Pneumatic tourniquet... patient's limb and inflated to reduce or totally occlude circulation during surgery. (b)...

  1. 21 CFR 878.5910 - Pneumatic tourniquet.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ...) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Therapeutic Devices § 878.5910 Pneumatic tourniquet... patient's limb and inflated to reduce or totally occlude circulation during surgery. (b)...

  2. 21 CFR 878.5910 - Pneumatic tourniquet.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ...) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Therapeutic Devices § 878.5910 Pneumatic tourniquet... patient's limb and inflated to reduce or totally occlude circulation during surgery. (b)...

  3. 21 CFR 878.5910 - Pneumatic tourniquet.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ...) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Therapeutic Devices § 878.5910 Pneumatic tourniquet... patient's limb and inflated to reduce or totally occlude circulation during surgery. (b)...

  4. Parallel pipelining

    SciTech Connect

    Joseph, D.D.; Bai, R.; Liao, T.Y.; Huang, A.; Hu, H.H.

    1995-09-01

    In this paper the authors introduce the idea of parallel pipelining for water lubricated transportation of oil (or other viscous material). A parallel system can have major advantages over a single pipe with respect to the cost of maintenance and continuous operation of the system, to the pressure gradients required to restart a stopped system and to the reduction and even elimination of the fouling of pipe walls in continuous operation. The authors show that the action of capillarity in small pipes is more favorable for restart than in large pipes. In a parallel pipeline system, they estimate the number of small pipes needed to deliver the same oil flux as in one larger pipe as N = (R/r){sup {alpha}}, where r and R are the radii of the small and large pipes, respectively, and {alpha} = 4 or 19/7 when the lubricating water flow is laminar or turbulent.

  5. RANGE INCREASER FOR PNEUMATIC GAUGES

    DOEpatents

    Fowler, A.H.; Seaborn, G.B. Jr.

    1960-09-27

    An improved pneumatic gage is offered in which the linear range has been increased without excessive air consumption. This has been accomplished by providing an expansible antechamber connected to the nozzle of the gage so that the position of the nozzle with respect to the workpiece is varied automatically by variation in pressure within the antechamber. This arrangement ensures that the nozzle-to-workpiece clearance is maintained within certain limits, thus obtaining a linear relation of air flow to nozzle-to-workpiece clearance over a wider range.

  6. A Study of Gas Economizing Pneumatic Cylinder

    NASA Astrophysics Data System (ADS)

    Li, T. C.; Wu, H. W.; Kuo, M. J.

    2006-10-01

    The pneumatic cylinder is the most typical actuator in the pneumatic equipment, and its mechanism is so simple that it is often used to operate point to point driving without the feedback loop in various automatic machines. But, the energy efficiency of pneumatic system is very poor compared with electrical systems and hydraulic systems. So, it is very important to discuss the energy saving for the pneumatic cylinder systems. In this thesis, we proposed three methods to apply the reduction in the air consumed for pneumatic cylinder systems. An air charge accumulator is used to absorb the exhausted compress air and a boost valve boosted the air to the higher pressure for used again. From the experiments, the direct used cylinder exhaust air may save about 40% of compress air.

  7. Pneumatic Variable Series Elastic Actuator.

    PubMed

    Zheng, Hao; Wu, Molei; Shen, Xiangrong

    2016-08-01

    Inspired by human motor control theory, stiffness control is highly effective in manipulation and human-interactive tasks. The implementation of stiffness control in robotic systems, however, has largely been limited to closed-loop control, and suffers from multiple issues such as limited frequency range, potential instability, and lack of contribution to energy efficiency. Variable-stiffness actuator represents a better solution, but the current designs are complex, heavy, and bulky. The approach in this paper seeks to address these issues by using pneumatic actuator as a variable series elastic actuator (VSEA), leveraging the compressibility of the working fluid. In this work, a pneumatic actuator is modeled as an elastic element with controllable stiffness and equilibrium point, both of which are functions of air masses in the two chambers. As such, for the implementation of stiffness control in a robotic system, the desired stiffness/equilibrium point can be converted to the desired chamber air masses, and a predictive pressure control approach is developed to control the timing of valve switching to obtain the desired air mass while minimizing control action. Experimental results showed that the new approach in this paper requires less expensive hardware (on-off valve instead of proportional valve), causes less control action in implementation, and provides good control performance by leveraging the inherent dynamics of the actuator.

  8. Caudal pneumaticity and pneumatic hiatuses in the sauropod dinosaurs Giraffatitan and Apatosaurus.

    PubMed

    Wedel, Mathew J; Taylor, Michael P

    2013-01-01

    Skeletal pneumaticity is found in the presacral vertebrae of most sauropod dinosaurs, but pneumaticity is much less common in the vertebrae of the tail. We describe previously unrecognized pneumatic fossae in the mid-caudal vertebrae of specimens of Giraffatitan and Apatosaurus. In both taxa, the most distal pneumatic vertebrae are separated from other pneumatic vertebrae by sequences of three to seven apneumatic vertebrae. Caudal pneumaticity is not prominent in most individuals of either of these taxa, and its unpredictable development means that it may be more widespread than previously recognised within Sauropoda and elsewhere in Saurischia. The erratic patterns of caudal pneumatization in Giraffatitan and Apatosaurus, including the pneumatic hiatuses, show that pneumatic diverticula were more broadly distributed in the bodies of the living animals than are their traces in the skeleton. Together with recently published evidence of cryptic diverticula--those that leave few or no skeletal traces--in basal sauropodomorphs and in pterosaurs, this is further evidence that pneumatic diverticula were widespread in ornithodirans, both across phylogeny and throughout anatomy.

  9. Caudal Pneumaticity and Pneumatic Hiatuses in the Sauropod Dinosaurs Giraffatitan and Apatosaurus

    PubMed Central

    Wedel, Mathew J.; Taylor, Michael P.

    2013-01-01

    Skeletal pneumaticity is found in the presacral vertebrae of most sauropod dinosaurs, but pneumaticity is much less common in the vertebrae of the tail. We describe previously unrecognized pneumatic fossae in the mid-caudal vertebrae of specimens of Giraffatitan and Apatosaurus. In both taxa, the most distal pneumatic vertebrae are separated from other pneumatic vertebrae by sequences of three to seven apneumatic vertebrae. Caudal pneumaticity is not prominent in most individuals of either of these taxa, and its unpredictable development means that it may be more widespread than previously recognised within Sauropoda and elsewhere in Saurischia. The erratic patterns of caudal pneumatization in Giraffatitan and Apatosaurus, including the pneumatic hiatuses, show that pneumatic diverticula were more broadly distributed in the bodies of the living animals than are their traces in the skeleton. Together with recently published evidence of cryptic diverticula—those that leave few or no skeletal traces—in basal sauropodomorphs and in pterosaurs, this is further evidence that pneumatic diverticula were widespread in ornithodirans, both across phylogeny and throughout anatomy. PMID:24205162

  10. NIF symmetry capsule modeling

    NASA Astrophysics Data System (ADS)

    Weber, S. V.; Casey, D. T.; Pino, J. E.; Rowley, D. P.; Smalyuk, V. A.; Spears, B. K.; Tipton, R. E.

    2013-10-01

    NIF CH ablator symmetry capsules are filled with hydrogen or helium gas. SymCaps have more moderate convergence ratios ~ 15 as opposed to ~ 35 for ignition capsules with DT ice layers, and better agreement has been achieved between simulations and experimental data. We will present modeling of capsules with CD layers and tritium fill, for which we are able to match the dependence of DT yield on recession distance of the CD layer from the gas. We can also match the performance of CH capsules with D3 He fill. The simulations include surface roughness, drive asymmetry, a mock-up of modulation introduced by the tent holding the capsule, and an empirical prescription for ablator-gas atomic mix. This work performed under the auspices of the U.S. Department of Energy by Lawrence Livermore National Laboratory under Contract DE-AC52-07NA27344.

  11. Mass flow measurement of pneumatically conveyed solids using electrical capacitance tomography

    NASA Astrophysics Data System (ADS)

    Sun, Meng; Liu, Shi; Lei, Jing; Li, Zhihong

    2008-04-01

    This paper describes a measurement system for mass flow measurement in a pneumatic pipeline. The system mainly consists of a volumetric concentration sensor and a velocity sensor. The concentration sensor is an electrical capacitance sensor which has eight electrodes; the velocity sensor is based on cross-correlating two signals derived from a pair of capacitance sensors. A cyclone is employed in this system where the sensors are placed in order to compensate the inhomogeneity of the sensor sensitivity. Experimental results obtained on a pneumatic conveyer circulating coal ash demonstrate that this system is capable of detecting various velocity profiles and solids distributions and providing an absolute mass flow rate of solids within a good agreement with the reference reading from load cells.

  12. The Lens Capsule

    PubMed Central

    Danysh, Brian P.; Duncan, Melinda K.

    2009-01-01

    The lens capsule is a modified basement membrane that completely surrounds the ocular lens. It is known that this extracellular matrix is important for both the structure and biomechanics of the lens in addition to providing informational cues to maintain lens cell phenotype. This review covers the development and structure of the lens capsule, lens diseases associated with mutations in extracellular matrix genes and the role of the capsule in lens function including those proposed for visual accommodation, selective permeability to infectious agents, and cell signaling. PMID:18773892

  13. Pneumatic tools for vitreoretinal surgery.

    PubMed

    Romano, Mario R; Vallejo-Garcia, Jose Luis; Randazzo, Alessandro; Vinciguerra, Paolo

    2012-01-01

    One of the difficulties of microsurgery is learning how to control physiological tremors. The pneumatic tool eliminates the physiological tremor, but no tactile feedback is provided. The manual tremor when closing the forceps is completely eliminated and the exact target can be more easily grabbed. Forceps closure pressure can rise up to 50 psi, whereas the scissors can be used in two modes: multicut and proportional. When performing bimanual surgery the pedal range is divided into two steps: in the first step, the forceps are controlled, and in the second step, the forceps remain closed. At the same time the scissors start to work in the preselected mode. No adverse events occurred and no iatrogenic retinal breaks were produced. Precision and control sensation were a grateful surprise.

  14. F-15 Pneumatic Forbody Controls

    NASA Technical Reports Server (NTRS)

    1994-01-01

    A series of test have been conducted in the Langley 30-by-60 Foot Tunnel to determine the effectiveness of several forebody control devices on a 10-percent-scale model of the F-15E. These test are part of a cooperative research program with the U.S. Air Force Wright Laboratory and the McDonnell Aircraft Company to determine the suitability of applying forebody controls to the F-15E aircraft. The forebody controls under investigation included mechanical concepts, such as deflectable strakes and rotating-randome devices, and pneumatic concepts, such as slotted-nozzle blowing. All these concepts are designed to provide increased maneuverability by enhancing yaw control at high angles of attack where conventional rudders become ineffective. Results from the tests show that the F-15E is well suited for the application of forebody-controls technology. After conducting a number of parametric variations, several mechanical and pneumatic forebody control options were identified that were capable of providing high levels of yaw control while minimizing the impact on other aircraft systems. Other desirable characteristics exhibited by these concepts were that the control effectiveness was retained over wide ranges of sideslip and that the level of yawing moment was easily controlled by varying either the mechanical deflection or the blowing rate. Subsequent piloted simulation studies conducted by the McDonnell Aircraft Company have shown that these improved levels of yaw control would significantly enhance the maneuverability of the aircraft. The promising results that were obtained during these tests have spawned interest in a flight-test program and possible future application to the F-15E aircraft.

  15. Pneumatic robotic systems for upper limb rehabilitation.

    PubMed

    Morales, Ricardo; Badesa, Francisco Javier; García-Aracil, Nicolás; Sabater, José María; Pérez-Vidal, Carlos

    2011-10-01

    The aim of rehabilitation robotic area is to research on the application of robotic devices to therapeutic procedures. The goal is to achieve the best possible motor, cognitive and functional recovery for people with impairments following various diseases. Pneumatic actuators are attractive for robotic rehabilitation applications because they are lightweight, powerful, and compliant, but their control has historically been difficult, limiting their use. This article first reviews the current state-of-art in rehabilitation robotic devices with pneumatic actuation systems reporting main features and control issues of each therapeutic device. Then, a new pneumatic rehabilitation robot for proprioceptive neuromuscular facilitation therapies and for relearning daily living skills: like taking a glass, drinking, and placing object on shelves is described as a case study and compared with the current pneumatic rehabilitation devices.

  16. Pipeline issues

    NASA Technical Reports Server (NTRS)

    Eisley, Joe T.

    1990-01-01

    The declining pool of graduates, the lack of rigorous preparation in science and mathematics, and the declining interest in science and engineering careers at the precollege level promises a shortage of technically educated personnel at the college level for industry, government, and the universities in the next several decades. The educational process, which starts out with a large number of students at the elementary level, but with an ever smaller number preparing for science and engineering at each more advanced educational level, is in a state of crisis. These pipeline issues, so called because the educational process is likened to a series of ever smaller constrictions in a pipe, were examined in a workshop at the Space Grant Conference and a summary of the presentations and the results of the discussion, and the conclusions of the workshop participants are reported.

  17. Geothermal pipeline

    SciTech Connect

    1997-08-01

    The Geothermal Pipeline is a progress and development update from the Geothermal Progress Monitor and includes brief descriptions of various geothermal projects around the world. The following topics are covered: The retirement of Geo-Heat Center Director Paul Lienau, announcement of two upcoming geothermal meetings, and a proposed geothermal power plant project in the Medicine Lake/Glass Mountain area of California. Also included is an article about the Bonneville Power Administration`s settlements with two California companies who had agreed to build geothermal power plants on the federal agency`s behalf, geothermal space heating projects and use of geothermal energy for raising red crayfish in Oregon, and some updates on geothermal projects in Minnesota, Pennsylvania, and China.

  18. Pneumatic fracturing of low permeability media

    SciTech Connect

    Schuring, J.R.

    1996-08-01

    Pneumatic fracturing of soils to enhance the removal and treatment of dense nonaqueous phase liquids is described. The process involves gas injection at a pressure exceeding the natural stresses and at a flow rate exceeding the permeability of the formation. The paper outlines geologic considerations, advantages and disadvantages, general technology considerations, low permeability media considerations, commercial availability, efficiency, and costs. Five case histories of remediation using pneumatic fracturing are briefly summarized. 11 refs., 2 figs., 1 tab.

  19. Promising pneumatic punchers for borehole drilling

    SciTech Connect

    A.A. Lipin

    2005-03-15

    The state of borehole drilling by downhole pneumatic punchers and their potential use in open and underground mining as well as in exploration for reliable sampling are analyzed. Performance specification is presented for the new-generation pneumatic punchers equipped with a pin tool, effectively operating at a compressed-air pressure of 0.5-0.7 MPa, and with an additional extended exhaust from the power stroke chamber during working cycle.

  20. Advances in Capsule Endoscopy.

    PubMed

    Scott, Ryan; Enns, Robert

    2015-09-01

    Wireless video capsule endoscopy (VCE) is a minimally invasive technology that has revolutionized the approach to small intestinal disease investigation and management. Designed primarily to provide diagnostic imaging of the small intestine, VCE is used predominantly for obscure gastrointestinal bleeding and suspected Crohn's disease; however, numerous other indications have been established, including the assessment of celiac disease, investigation of small bowel tumors, and surveillance of hereditary polyposis syndromes. Since the introduction of small bowel VCE in 2000, more than 1600 articles have been published describing the evolution of this technology. The main adverse outcome is capsule retention, which can potentially be avoided by careful patient selection or by using a patency capsule. Despite the numerous advances in the past 15 years, limitations such as incomplete VCE studies, missed lesions, and time-consuming reporting remain. The inability to control capsule movement for the application of targeted therapy or the acquisition of tissue for histologic analysis remains among the greatest challenges in the further development of capsule technology. This article outlines the recent technological and clinical advances in VCE and the future directions of research in this field.

  1. Advances in Capsule Endoscopy

    PubMed Central

    Scott, Ryan

    2015-01-01

    Wireless video capsule endoscopy (VCE) is a minimally invasive technology that has revolutionized the approach to small intestinal disease investigation and management. Designed primarily to provide diagnostic imaging of the small intestine, VCE is used predominantly for obscure gastrointestinal bleeding and suspected Crohn’s disease; however, numerous other indications have been established, including the assessment of celiac disease, investigation of small bowel tumors, and surveillance of hereditary polyposis syndromes. Since the introduction of small bowel VCE in 2000, more than 1600 articles have been published describing the evolution of this technology. The main adverse outcome is capsule retention, which can potentially be avoided by careful patient selection or by using a patency capsule. Despite the numerous advances in the past 15 years, limitations such as incomplete VCE studies, missed lesions, and time-consuming reporting remain. The inability to control capsule movement for the application of targeted therapy or the acquisition of tissue for histologic analysis remains among the greatest challenges in the further development of capsule technology. This article outlines the recent technological and clinical advances in VCE and the future directions of research in this field. PMID:27482183

  2. 76 FR 70953 - Pipeline Safety: Safety of Gas Transmission Pipelines

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-11-16

    ...: Safety of Gas Transmission Pipelines AGENCY: Pipeline and Hazardous Materials Safety Administration... Rulemaking (ANPRM) titled: ``Safety of Gas Transmission Pipelines'' seeking comments on the need for changes to the regulations covering gas transmission pipelines. PHMSA has received requests to extend...

  3. Evaluation of posterior clinoid process pneumatization by multidetector computed tomography.

    PubMed

    Burulday, Veysel; Akgül, Mehmet Hüseyin; Muluk, Nuray Bayar; Ozveren, Mehmet Faik; Kaya, Ahmet

    2016-10-21

    In the present study, we investigated the types and ratio of posterior clinoid process (PCP) pneumatization in paranasal sinus multidetector computed tomography (MDCT). Paranasal MDCT images of 541 subjects (227 males, 314 females), between 15 and 65 years old, were included into the study. Pneumatization of anterior clinoid process and pneumatization types (I, II, or III) were evaluated in the males and females. PCP pneumatization was detected in 20.7 % of the males and 11.5 % of the females. Right, left, and bilateral PCP pneumatizations were detected in 7.9, 5.7, and 7.0 % of the males and 2.9, 3.2, and 4.5 % of the females, respectively. PCP pneumatization of the males is significantly higher than the females. The most detected type of pneumatization was type I (61.2 %) for all groups. In right, left, and bilateral pneumatizations separately, type I pneumatization was the most detected pneumatization type with the ratio of the 70.4, 65.2, and 50.0 %, respectively. In males, type I (61.7 %), and similarly in females, type I (60.6 %) pneumatization were detected more. Type II and type III pneumatizations were detected in decreasing order in both groups. In younger subjects, pneumatization of posterior clinoid process was found as higher, and in older subjects, PCP pneumatization was found as lower. Sclerosis process related to the aging may be responsible for the lower pneumatization ratios in older subjects. Structure of the surrounding regions of PCP is important for surgical procedures related to cavernous sinus, basilar apex aneurysms, and mass lesions. Preoperative radiological examinations are useful for operative planning. Any anomalies to PCP can cause unnecessary injury to the neurovascular complex structure around the cavernous sinus or postclinoidectomy CSF fistulas. Posterior clinoidectomies should be avoided in patients with type III PCP pneumatization to prevent CSF fistulas.

  4. Gelatin capsule in stomach (image)

    MedlinePlus

    ... detect the presence of intestinal parasites. A weighted gelatin capsule attached to a string is swallowed and left in place. After about 4 hours, the gelatin capsule is pulled out of the stomach by ...

  5. [Development of an adaptive pneumatic tourniquet].

    PubMed

    Liu, Hongyun; Zhang, Zhengbo; Li, Kaiyuan; Guo, Junyan; Wang, Weidong

    2012-06-01

    A new adaptive pneumatic tourniquet was developed for limb operation and first-aid. The crucial hardware circuits of the adaptive pneumatic tourniquet were designed based on the microprocessor C8051F340 and blood pressure module CSN602, software was programmed and an experiment was carried out for verifying the system. Results showed that the prototype could measure accurately systolic blood pressure, heart rate and other relative parameters and the designed device could adjust tourniquet cuff's pressure through inflation and deflation according to systolic blood pressure and limb circumference. This designed system integrated the advantages of the adaptive pneumatic tourniquet, and could be used for controlling life-threatening extremity hemorrhage operation and maintaining a bloodless opeation field.

  6. Pneumatic Rupture of Rectosigmoid; a Case Report.

    PubMed

    Montazeri, Mohammad; Farhangi, Bahman; Montazeri, Mahmood

    2014-01-01

    Pneumatic rectosigmoid rapture is usually occurred following the inappropriate fun by direct entering a high volume of the air through the pneumatic device to the anus. Such an event was reported for the first time in 1904 by Stone. Diagnosis and treatment of such injuries are often delayed because of some social limitations and preventing the patient form explaining the event. Colon sigmoid rupture and pneumoperitoneum is one of the most dangerous and life treating complications of entering a high volume of the air to the rectum in a short time. There are only a few reports regarding the similar cases. Here, a case of pneumatic rectosigmoid rapture was reported in a 53 year-old male following an inappropriate fun.

  7. 7 CFR 3201.86 - Pneumatic equipment lubricants.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 7 Agriculture 15 2014-01-01 2014-01-01 false Pneumatic equipment lubricants. 3201.86 Section 3201... PROCUREMENT Designated Items § 3201.86 Pneumatic equipment lubricants. (a) Definition. Lubricants designed... this part, will give a procurement preference for qualifying biobased pneumatic equipment...

  8. 7 CFR 3201.86 - Pneumatic equipment lubricants.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 7 Agriculture 15 2013-01-01 2013-01-01 false Pneumatic equipment lubricants. 3201.86 Section 3201... PROCUREMENT Designated Items § 3201.86 Pneumatic equipment lubricants. (a) Definition. Lubricants designed... this part, will give a procurement preference for qualifying biobased pneumatic equipment...

  9. 21 CFR 870.2780 - Hydraulic, pneumatic, or photoelectric plethysmographs.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Hydraulic, pneumatic, or photoelectric... § 870.2780 Hydraulic, pneumatic, or photoelectric plethysmographs. (a) Identification. A hydraulic... using hydraulic, pneumatic, or photoelectric measurement techniques. (b) Classification. Class...

  10. 21 CFR 870.2780 - Hydraulic, pneumatic, or photoelectric plethysmographs.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Hydraulic, pneumatic, or photoelectric... § 870.2780 Hydraulic, pneumatic, or photoelectric plethysmographs. (a) Identification. A hydraulic... using hydraulic, pneumatic, or photoelectric measurement techniques. (b) Classification. Class...

  11. 21 CFR 870.2780 - Hydraulic, pneumatic, or photoelectric plethysmographs.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Hydraulic, pneumatic, or photoelectric... § 870.2780 Hydraulic, pneumatic, or photoelectric plethysmographs. (a) Identification. A hydraulic... using hydraulic, pneumatic, or photoelectric measurement techniques. (b) Classification. Class...

  12. 21 CFR 870.2780 - Hydraulic, pneumatic, or photoelectric plethysmographs.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Hydraulic, pneumatic, or photoelectric... § 870.2780 Hydraulic, pneumatic, or photoelectric plethysmographs. (a) Identification. A hydraulic... using hydraulic, pneumatic, or photoelectric measurement techniques. (b) Classification. Class...

  13. 21 CFR 870.2780 - Hydraulic, pneumatic, or photoelectric plethysmographs.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Hydraulic, pneumatic, or photoelectric... § 870.2780 Hydraulic, pneumatic, or photoelectric plethysmographs. (a) Identification. A hydraulic... using hydraulic, pneumatic, or photoelectric measurement techniques. (b) Classification. Class...

  14. 21 CFR 882.4370 - Pneumatic cranial drill motor.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Pneumatic cranial drill motor. 882.4370 Section... drill motor. (a) Identification. A pneumatic cranial drill motor is a pneumatically operated power source used with removable rotating surgical cutting tools or drill bits on a patient's skull....

  15. 21 CFR 882.4370 - Pneumatic cranial drill motor.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Pneumatic cranial drill motor. 882.4370 Section... drill motor. (a) Identification. A pneumatic cranial drill motor is a pneumatically operated power source used with removable rotating surgical cutting tools or drill bits on a patient's skull....

  16. 21 CFR 882.4370 - Pneumatic cranial drill motor.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Pneumatic cranial drill motor. 882.4370 Section... drill motor. (a) Identification. A pneumatic cranial drill motor is a pneumatically operated power source used with removable rotating surgical cutting tools or drill bits on a patient's skull....

  17. 49 CFR 236.817 - Switch, electro-pneumatic.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 4 2013-10-01 2013-10-01 false Switch, electro-pneumatic. 236.817 Section 236.817 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION... Switch, electro-pneumatic. A switch operated by an electro-pneumatic switch-and-lock movement....

  18. 49 CFR 236.817 - Switch, electro-pneumatic.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 4 2014-10-01 2014-10-01 false Switch, electro-pneumatic. 236.817 Section 236.817 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION... Switch, electro-pneumatic. A switch operated by an electro-pneumatic switch-and-lock movement....

  19. 49 CFR 236.817 - Switch, electro-pneumatic.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 4 2012-10-01 2012-10-01 false Switch, electro-pneumatic. 236.817 Section 236.817 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION... Switch, electro-pneumatic. A switch operated by an electro-pneumatic switch-and-lock movement....

  20. PNEUMATIC PUMP TEST FOR DESIGN OF SOIL VACUUM EXTRACTION

    EPA Science Inventory

    In-situ pneumatic pumping tests were performed to estimate the pneumatic permeability at a site containing soils contaminated with aviation gasoline. Determination of pneumatic permeability was necessary to evaluate soil-air discharge or pore volume exchange rates. Pressure propa...

  1. 49 CFR 236.817 - Switch, electro-pneumatic.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Switch, electro-pneumatic. 236.817 Section 236.817 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION... Switch, electro-pneumatic. A switch operated by an electro-pneumatic switch-and-lock movement....

  2. 49 CFR 236.817 - Switch, electro-pneumatic.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 4 2011-10-01 2011-10-01 false Switch, electro-pneumatic. 236.817 Section 236.817 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION... Switch, electro-pneumatic. A switch operated by an electro-pneumatic switch-and-lock movement....

  3. 21 CFR 882.4370 - Pneumatic cranial drill motor.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Pneumatic cranial drill motor. 882.4370 Section 882.4370 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... drill motor. (a) Identification. A pneumatic cranial drill motor is a pneumatically operated...

  4. 21 CFR 882.4370 - Pneumatic cranial drill motor.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Pneumatic cranial drill motor. 882.4370 Section 882.4370 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... drill motor. (a) Identification. A pneumatic cranial drill motor is a pneumatically operated...

  5. Pneumatically switchable graded index metamaterial lens

    NASA Astrophysics Data System (ADS)

    Khodasevych, I. E.; Shadrivov, I. V.; Powell, D. A.; Rowe, W. S. T.; Mitchell, A.

    2013-01-01

    A low-profile pneumatically switchable graded index metamaterial lens operating at 9 GHz is proposed and practically demonstrated. An effective graded refractive index is engineered using an array of electric resonators of differing resonant frequency. Normal orientation of the resonators allows ultrathin single metamaterial layer lens design. Switching between focusing and non-focusing states is practically demonstrated by shorting the gaps in split ring resonators and eliminating the resonant response and the phase difference between the elements across the lens with pneumatically actuated metal patches that are pressed against the gaps of the resonators as the pressure in the chamber is reduced.

  6. Guidelines help design pneumatic control systems

    SciTech Connect

    Curry, R.N.

    1981-01-26

    The three areas of particular interest to the gas-transmission engineer about pneumatic-instrument-operated control valves are (1) the fail-position probability of a system, (2) the designated action required for each component in the pneumatic circuit, and (3) the schematically defined position of each component. Compared with self-operated control valves, the instrument-operated systems perform many more functions; they can control the flow and the volume or flow-volume combinations, with both pressure override and underride, and will adapt conveniently to remote operation. Schematic diagrams illustrate the numerous system designs possible for pressure-regulation, flow-control, and relief-valve duties.

  7. 77 FR 70543 - Pipeline Safety: Meeting of the Gas Pipeline Advisory Committee and the Liquid Pipeline Advisory...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-11-26

    ... Pipeline Advisory Committee and the Liquid Pipeline Advisory Committee AGENCY: Pipeline and Hazardous... Technical Pipeline Safety Standards Committee, and the Liquid Pipeline Advisory Committee (LPAC), also known as the Technical Hazardous Liquid Pipeline Safety Standards Committee. The committees will meet...

  8. Vertebral Pneumaticity in the Ornithomimosaur Archaeornithomimus (Dinosauria: Theropoda) Revealed by Computed Tomography Imaging and Reappraisal of Axial Pneumaticity in Ornithomimosauria

    PubMed Central

    Watanabe, Akinobu; Eugenia Leone Gold, Maria; Brusatte, Stephen L.; Benson, Roger B. J.; Choiniere, Jonah; Davidson, Amy; Norell, Mark A.

    2015-01-01

    Among extant vertebrates, pneumatization of postcranial bones is unique to birds, with few known exceptions in other groups. Through reduction in bone mass, this feature is thought to benefit flight capacity in modern birds, but its prevalence in non-avian dinosaurs of variable sizes has generated competing hypotheses on the initial adaptive significance of postcranial pneumaticity. To better understand the evolutionary history of postcranial pneumaticity, studies have surveyed its distribution among non-avian dinosaurs. Nevertheless, the degree of pneumaticity in the basal coelurosaurian group Ornithomimosauria remains poorly known, despite their potential to greatly enhance our understanding of the early evolution of pneumatic bones along the lineage leading to birds. Historically, the identification of postcranial pneumaticity in non-avian dinosaurs has been based on examination of external morphology, and few studies thus far have focused on the internal architecture of pneumatic structures inside the bones. Here, we describe the vertebral pneumaticity of the ornithomimosaur Archaeornithomimus with the aid of X-ray computed tomography (CT) imaging. Complementary examination of external and internal osteology reveals (1) highly pneumatized cervical vertebrae with an elaborate configuration of interconnected chambers within the neural arch and the centrum; (2) anterior dorsal vertebrae with pneumatic chambers inside the neural arch; (3) apneumatic sacral vertebrae; and (4) a subset of proximal caudal vertebrae with limited pneumatic invasion into the neural arch. Comparisons with other theropod dinosaurs suggest that ornithomimosaurs primitively exhibited a plesiomorphic theropod condition for axial pneumaticity that was extended among later taxa, such as Archaeornithomimus and large bodied Deinocheirus. This finding corroborates the notion that evolutionary increases in vertebral pneumaticity occurred in parallel among independent lineages of bird

  9. Improving dynamic performances of PWM-driven servo-pneumatic systems via a novel pneumatic circuit.

    PubMed

    Taghizadeh, Mostafa; Ghaffari, Ali; Najafi, Farid

    2009-10-01

    In this paper, the effect of pneumatic circuit design on the input-output behavior of PWM-driven servo-pneumatic systems is investigated and their control performances are improved using linear controllers instead of complex and costly nonlinear ones. Generally, servo-pneumatic systems are well known for their nonlinear behavior. However, PWM-driven servo-pneumatic systems have the advantage of flexibility in the design of pneumatic circuits which affects the input-output linearity of the whole system. A simple pneumatic circuit with only one fast switching valve is designed which leads to a quasi-linear input-output relation. The quasi-linear behavior of the proposed circuit is verified both experimentally and by simulations. Closed loop position control experiments are then carried out using linear P- and PD-controllers. Since the output position is noisy and cannot be directly differentiated, a Kalman filter is designed to estimate the velocity of the cylinder. Highly improved tracking performances are obtained using these linear controllers, compared to previous works with nonlinear controllers.

  10. Microfluidic Pneumatic Logic Circuits and Digital Pneumatic Microprocessors for Integrated Microfluidic Systems

    PubMed Central

    Rhee, Minsoung

    2010-01-01

    We have developed pneumatic logic circuits and microprocessors built with microfluidic channels and valves in polydimethylsiloxane (PDMS). The pneumatic logic circuits perform various combinational and sequential logic calculations with binary pneumatic signals (atmosphere and vacuum), producing cascadable outputs based on Boolean operations. A complex microprocessor is constructed from combinations of various logic circuits and receives pneumatically encoded serial commands at a single input line. The device then decodes the temporal command sequence by spatial parallelization, computes necessary logic calculations between parallelized command bits, stores command information for signal transportation and maintenance, and finally executes the command for the target devices. Thus, such pneumatic microprocessors will function as a universal on-chip control platform to perform complex parallel operations for large-scale integrated microfluidic devices. To demonstrate the working principles, we have built 2-bit, 3-bit, 4-bit, and 8-bit microprecessors to control various target devices for applications such as four color dye mixing, and multiplexed channel fluidic control. By significantly reducing the need for external controllers, the digital pneumatic microprocessor can be used as a universal on-chip platform to autonomously manipulate microfluids in a high throughput manner. PMID:19823730

  11. Microfluidic pneumatic logic circuits and digital pneumatic microprocessors for integrated microfluidic systems.

    PubMed

    Rhee, Minsoung; Burns, Mark A

    2009-11-07

    We have developed pneumatic logic circuits and microprocessors built with microfluidic channels and valves in polydimethylsiloxane (PDMS). The pneumatic logic circuits perform various combinational and sequential logic calculations with binary pneumatic signals (atmosphere and vacuum), producing cascadable outputs based on Boolean operations. A complex microprocessor is constructed from combinations of various logic circuits and receives pneumatically encoded serial commands at a single input line. The device then decodes the temporal command sequence by spatial parallelization, computes necessary logic calculations between parallelized command bits, stores command information for signal transportation and maintenance, and finally executes the command for the target devices. Thus, such pneumatic microprocessors will function as a universal on-chip control platform to perform complex parallel operations for large-scale integrated microfluidic devices. To demonstrate the working principles, we have built 2-bit, 3-bit, 4-bit, and 8-bit microprocessors to control various target devices for applications such as four color dye mixing, and multiplexed channel fluidic control. By significantly reducing the need for external controllers, the digital pneumatic microprocessor can be used as a universal on-chip platform to autonomously manipulate microfluids in a high throughput manner.

  12. Distortion Of Pressure Signals In Pneumatic Tubes

    NASA Technical Reports Server (NTRS)

    Whitmore, Stephen A.; Gilyard, Glenn B.; Curry, Robert; Lindsey, William

    1993-01-01

    NASA technical memorandum describes experimental investigation of distorting effects of propagation of pressure signals along narrow pneumatic tubes from pressure-sensing orifices on surfaces of models or aircraft to pressure sensors distant from orifices. Pressure signals distorted principally by frictional damping along walls of tubes and by reflections at orifice and sensor ends.

  13. Pneumatic boot for helicopter rotor deicing

    NASA Technical Reports Server (NTRS)

    Blaha, B. J.; Evanich, P. L.

    1981-01-01

    Pneumatic deicer boots for helicopter rotor blades were tested. The tests were conducted in the 6 by 9 ft icing research tunnel on a stationary section of a UH-IH helicopter main rotor blade. The boots were effective in removing ice and in reducing aerodynamic drag due to ice.

  14. 49 CFR 236.590 - Pneumatic apparatus.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ..., DEPARTMENT OF TRANSPORTATION RULES, STANDARDS, AND INSTRUCTIONS GOVERNING THE INSTALLATION, INSPECTION, MAINTENANCE, AND REPAIR OF SIGNAL AND TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES Automatic Train Stop.... Automatic train stop, train control, or cab signal pneumatic apparatus shall be inspected, cleaned, and...

  15. 49 CFR 236.590 - Pneumatic apparatus.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ..., DEPARTMENT OF TRANSPORTATION RULES, STANDARDS, AND INSTRUCTIONS GOVERNING THE INSTALLATION, INSPECTION, MAINTENANCE, AND REPAIR OF SIGNAL AND TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES Automatic Train Stop.... Automatic train stop, train control, or cab signal pneumatic apparatus shall be inspected, cleaned, and...

  16. 49 CFR 236.590 - Pneumatic apparatus.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ..., DEPARTMENT OF TRANSPORTATION RULES, STANDARDS, AND INSTRUCTIONS GOVERNING THE INSTALLATION, INSPECTION, MAINTENANCE, AND REPAIR OF SIGNAL AND TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES Automatic Train Stop.... Automatic train stop, train control, or cab signal pneumatic apparatus shall be inspected, cleaned, and...

  17. Assessment of Pneumatic Controller Emission Measurements ...

    EPA Pesticide Factsheets

    Oil and Natural Gas (ONG) production facilities have the potential to emit greenhouse gases such as methane (CH4) and other hydrocarbons (HCs) to the atmosphere. ONG production sites have multiple emission sources including storage tank venting, enclosed combustion devices, engine exhaust, pneumatic controllers and uncontrolled leaks. Accounting for up to 37.8 percent of CH4 emissions, pneumatic controllers are one of the most significant sources of CH4 in ONG production field operations. Recent measurement studies used the only commercially-available high volume sampling (HVS) technology (Bacharach Hi Flow Sampler, Bacharach, Inc., New Kensington, PA) to quantify CH4 emission rates of pneumatic devices on ONG production pads and compare to inventory estimates. Other studies indicate that this HVS may malfunction, causing underestimates of emissions in certain scenarios encountered in ONG production and should not be used for some sources such as heavy emissions from condensate storage tanks. The HVS malfunction can occur on relatively large emissions, where the measured leak concentrations exceed 5%, and is ascribed to a sensor transition failure in the instrument. The HVS malfunction is believed to be exacerbated by several factors (large emission rates, amount of non-CH4 HCs in the emission stream, non-optimal HVS calibration frequency, firmware, and emission measurement coupling geometries). The degree to which HVS measurements of emissions from pneumatic co

  18. Analysis of fine coal pneumatic systems

    SciTech Connect

    Mathur, M.P.; Rohatgi, N.D.; Klinzing, G.E.

    1987-01-01

    Many fossil fuel energy processes depend on the movement of solids by pneumatic transport. Despite the considerable amount of work reported in the literature on pneumatic transport, the design of new industrial systems for new products continues to rely to a great extent on empiricism. A pilot-scale test facility has been constructed at Pittsburgh Energy Technology Center (PETC) and is equipped with modern sophisticated measuring techniques (such as Pressure Transducers, Auburn Monitors, Micro Motion Mass flowmeters) and an automatic computer-controlled data acquisition system to study the effects of particle pneumatic transport. Pittsburgh Seam and Montana rosebud coals of varying size consist and moisture content were tested in the atmospheric and pressurized coal flow test loops (AP/CFTL and HP/CFTL) at PETC. The system parameters included conveying gas velocity, injector tank pressure, screw conveyor speed, pipe radius, and pipe bends. In the following report, results from the coal flow tests were presented and analyzed. Existing theories and correlations on two-phase flows were reviewed. Experimental data were compared with values calculated from empirically or theoretically derived equations available in the literature, and new correlations were proposed, when applicable, to give a better interpretation of the data and a better understanding of the various flow regimes involved in pneumatic transport. 55 refs., 56 figs., 6 tabs.

  19. PNEUMATIC FRACTIONATOR FOR CLEANING GINNED LINT

    Technology Transfer Automated Retrieval System (TEKTRAN)

    The pneumatic fractionator has long been used to determine foreign matter content of seed cotton at the USDA Cotton Ginning Laboratories. Spawned from discussions at a Cotton Incorporated Lint Cleaning Summit and building on 1970s research at the Southwestern Cotton Ginning Research Laboratory, an e...

  20. First Approach of Pneumatic Anthropomorphic Hand

    DTIC Science & Technology

    2001-10-25

    weight and minimum consumption, minimum control and natural appearance. Keywords- Anthropomorphic, hand, Pneumatic system, Prosthesis 1. INTRODUCTION...and controls that are compared with the tasks that Human hand can carry out. Each project determines the diverse possibilities of manipulation and...increases the possibilities of acceptance of prosthesis by the user. Multiple degrees of freedom of the prosthesis are difficult to control independently

  1. Enhancing in situ bioremediation with pneumatic fracturing

    SciTech Connect

    Anderson, D.B.; Peyton, B.M.; Liskowitz, J.L.; Fitzgerald, C.; Schuring, J.R.

    1994-04-01

    A major technical obstacle affecting the application of in situ bioremediation is the effective distribution of nutrients to the subsurface media. Pneumatic fracturing can increase the permeability of subsurface formations through the injection of high pressure air to create horizontal fracture planes, thus enhancing macro-scale mass-transfer processes. Pneumatic fracturing technology was demonstrated at two field sites at Tinker Air Force Base, Oklahoma City, Oklahoma. Tests were performed to increase the permeability for more effective bioventing, and evaluated the potential to increase permeability and recovery of free product in low permeability soils consisting of fine grain silts, clays, and sedimentary rock. Pneumatic fracturing significantly improved formation permeability by enhancing secondary permeability and by promoting removal of excess soil moisture from the unsaturated zone. Postfracture airflows were 500% to 1,700% higher than prefracture airflows for specific fractured intervals in the formation. This corresponds to an average prefracturing permeability of 0.017 Darcy, increasing to an average of 0.32 Darcy after fracturing. Pneumatic fracturing also increased free-product recovery rates of number 2 fuel from an average of 587 L (155 gal) per month before fracturing to 1,647 L (435 gal) per month after fracturing.

  2. Sweat collection capsule

    NASA Technical Reports Server (NTRS)

    Greenleaf, J. E.; Delaplaine, R. W. (Inventor)

    1980-01-01

    A sweat collection capsule permitting quantitative collection of sweat is described. The device consists of a frame held immobile on the skin, a closure secured to the frame and absorbent material located next to the skin in a cavity formed by the frame and the closure. The absorbent material may be removed from the device by removing the closure from the frame while the frame is held immobile on the skin.

  3. Capsule-train stability

    NASA Astrophysics Data System (ADS)

    Bryngelson, Spencer H.; Freund, Jonathan B.

    2016-07-01

    Elastic capsules flowing in small enough tubes, such as red blood cells in capillaries, are well known to line up into regular single-file trains. The stability of such trains in somewhat wider channels, where this organization is not observed, is studied in a two-dimensional model system that includes full coupling between the viscous flow and suspended capsules. A diverse set of linearly amplifying disturbances, both long-time asymptotic (modal) and transient (nonmodal) perturbations, is identified and analyzed. These have a range of amplification rates and their corresponding forms are wavelike, typically dominated by one of five principal perturbation classes: longitudinal and transverse translations, tilts, and symmetric and asymmetric shape distortions. Finite-amplitude transiently amplifying perturbations are shown to provide a mechanism that can bypass slower asymptotic modal linear growth and precipitate the onset of nonlinear effects. Direct numerical simulations are used to verify the linear analysis and track the subsequent transition of the regular capsule trains into an apparently chaotic flow.

  4. Pneumatically Actuated Miniature Peristaltic Vacuum Pumps

    NASA Technical Reports Server (NTRS)

    Feldman, Sabrina; Feldman, Jason; Svehla, Danielle

    2003-01-01

    Pneumatically actuated miniature peristaltic vacuum pumps have been proposed for incorporation into advanced miniature versions of scientific instruments that depend on vacuum for proper operation. These pumps are expected to be capable of reaching vacuum-side pressures in the torr to millitorr range (from .133 down to .0.13 Pa). Vacuum pumps that operate in this range are often denoted roughing pumps. In comparison with previously available roughing pumps, these pumps are expected to be an order of magnitude less massive and less power-hungry. In addition, they would be extremely robust, and would operate with little or no maintenance and without need for oil or other lubricants. Portable mass spectrometers are typical examples of instruments that could incorporate the proposed pumps. In addition, the proposed pumps could be used as roughing pumps in general laboratory applications in which low pumping rates could be tolerated. The proposed pumps could be designed and fabricated in conventionally machined and micromachined versions. A typical micromachined version (see figure) would include a rigid glass, metal, or plastic substrate and two layers of silicone rubber. The bottom silicone layer would contain shallow pump channels covered by silicone arches that could be pushed down pneumatically to block the channels. The bottom silicone layer would be covered with a thin layer of material with very low gas permeability, and would be bonded to the substrate everywhere except in the channel areas. The top silicone layer would be attached to the bottom silicone layer and would contain pneumatic- actuation channels that would lie crosswise to the pump channels. This version is said to be micromachined because the two silicone layers containing the channels would be fabricated by casting silicone rubber on micromachined silicon molds. The pneumatic-actuation channels would be alternately connected to a compressed gas and (depending on pump design) either to atmospheric

  5. Adhesive capsulitis of the shoulder.

    PubMed

    Neviaser, Andrew S; Neviaser, Robert J

    2011-09-01

    Adhesive capsulitis is characterized by painful, gradual loss of active and passive shoulder motion resulting from fibrosis and contracture of the joint capsule. Other shoulder pathology can produce a similar clinical picture, however, and must be considered. Management is based on the underlying cause of pain and stiffness, and determination of the etiology is essential. Subtle clues in the history and physical examination can help differentiate adhesive capsulitis from other conditions that cause a stiff, painful shoulder. The natural history of adhesive capsulitis is a matter of controversy. Management of true capsular restriction of motion (ie, true adhesive capsulitis) begins with gentle, progressive stretching exercises. Most patients improve with nonsurgical treatment. Indications for surgery should be individualized. Failure to obtain symptomatic improvement and continued functional disability following ≥6 months of physical therapy is a general guideline for surgical intervention. Diligent postoperative therapy to maintain motion is required to minimize recurrence of adhesive capsulitis.

  6. Hohlraum Simulations for Symergy Capsules

    NASA Astrophysics Data System (ADS)

    Goldman, S. R.; Hoffman, N. M.; Kyrala, G. A.; Wilson, D. C.

    2006-10-01

    The use of a single capsule implosion within a hohlraum to provide information on both the asymmetry of the radiation drive impinging on the capsule and the total energy absorbed by it has led to the concept of experiments with ``symergy'' capsules. We present simulations for planned shots at Omega with hohlraum drive approximating the first 6 ns of the actual NIF ignition drive and surrogate capsules for the NIF ignition capsule. The hohlraum modeling can assess the effects of hohlraum gas fill, laser timing variations and beam pointings. In addition to its immediate design use, it should be useful in validating both the predictive capability for observed symergy capsule responses and the modeling of the initial stage of the NIF ignition process. N.M. Hoffman, D. C. Wilson, and G. A. Kyrala, 2006 High-Temperature Diagnostics Conference, May 2006, Williamsburg, VA USA, to appear in Rev Sci Inst. 77 (2006)

  7. Electrostatic sensors applied to the measurement of electric charge transfer in gas solids pipelines

    NASA Astrophysics Data System (ADS)

    Woodhead, S. R.; Denham, J. C.; Armour-Chelu, D. I.

    2005-01-01

    This paper describes the development of a number of electric charge sensors. The sensors have been developed specifically to investigate triboelectric charge transfer which takes place between particles and the pipeline wall, when powdered materials are conveyed through a pipeline using air. A number of industrial applications exist for such gas solids pipelines, including pneumatic conveyors, vacuum cleaners and dust extraction systems. The build-up of electric charge on pipelines and powdered materials can lead to electrostatic discharge and so is of interest from a safety viewpoint. The charging of powders can also adversely affect their mechanical handling characteristics and so is of interest to handling equipment engineers. The paper presents the design of the sensors, the design of the electric charge test rig and electric charge measurement test results.

  8. Multinode reconfigurable pipeline computer

    NASA Technical Reports Server (NTRS)

    Nosenchuck, Daniel M. (Inventor); Littman, Michael G. (Inventor)

    1989-01-01

    A multinode parallel-processing computer is made up of a plurality of innerconnected, large capacity nodes each including a reconfigurable pipeline of functional units such as Integer Arithmetic Logic Processors, Floating Point Arithmetic Processors, Special Purpose Processors, etc. The reconfigurable pipeline of each node is connected to a multiplane memory by a Memory-ALU switch NETwork (MASNET). The reconfigurable pipeline includes three (3) basic substructures formed from functional units which have been found to be sufficient to perform the bulk of all calculations. The MASNET controls the flow of signals from the memory planes to the reconfigurable pipeline and vice versa. the nodes are connectable together by an internode data router (hyperspace router) so as to form a hypercube configuration. The capability of the nodes to conditionally configure the pipeline at each tick of the clock, without requiring a pipeline flush, permits many powerful algorithms to be implemented directly.

  9. Oceanic pipeline computations

    SciTech Connect

    Marks, A.

    1980-01-01

    yechnical and economic feasibility, design, and construction of oil, gas, and two-phase oceanic pipelines systems are discussed. In addition, formulae, references, examples, and programmable calculator software (Hewlett-Packard-67) are given. The contents include: preliminary pipeline sizing; fluid characteristics; preliminary hydraulics; oceanographis; preliminary corridor selection; route selection; final pipeline design; hydraulic design; wall thickness selection; oceanographic design computations; stress analysis; and construction parameters. (JMT)

  10. Capsule endoscopy in portal hypertension.

    PubMed

    Rondonotti, Emanuele; Villa, Federica; Dell' Era, Alessandra; Tontini, Gian Eugenio; de Franchis, Roberto

    2010-05-01

    Since the introduction of small bowel capsule endoscopy, and more recently of esophageal capsule endoscopy, these diagnostic tools have become available for the evaluation of the consequences of portal hypertension in the esophagus, stomach, and small intestine. The main advantage of the esophageal and the small bowel capsule is the relatively less invasiveness that could potentially increase patients' adherence to endoscopic screening/surveillance programs. When esophageal capsule endoscopy was compared with traditional gastroscopy, it showed good sensitivity and specificity in recognizing the presence and the size of esophageal varices. However, the results are not consistent among studies, and more data are needed.

  11. A pneumatic cylinder driving polyhedron mobile mechanism

    NASA Astrophysics Data System (ADS)

    Ding, Wan; Kim, Sung-Chan; Yao, Yan-An

    2012-03-01

    A novel pneumatic cylinder driving polyhedron mobile mechanism is proposed in this paper. The mechanism is comprised of 5 tetrahedrons which includes a pneumatic cylinder in each edge. It locomotes by rolling and the rolling principle refers to the center of mass (CM) of the mechanism moved out of the supporting area and let it tip over through the controlling of the motion sequence of these cylinders. Firstly, the mathematical model is built to analysis the relation between the configuration and the CM of the mechanism. Then, a binary control strategy is developed to simplify and improve the control of this mobile mechanism. After that, dynamic simulation is performed to testify the analytical validity and feasibility of the rolling gaits. At last, a prototype is fabricated to achieve the rolling successfully to demonstrate the proposed concept.

  12. Pneumatic conveying of materials at partial gravity

    NASA Technical Reports Server (NTRS)

    Sullivan, Thomas A.; Koenig, Elissa; Knudsen, Christian W.; Gibson, Michael A.

    1992-01-01

    The feasibility of pneumatic transfer for the movement of regolith at a lunar base is evaluated. Operation of pneumatic conveying systems at partial (lunar and Mars) gravity on NASA's KC-135 aircraft allowed the determination of some key parameters necessary for the design of an operable system. Both horizontal and vertical transfer is studied. In the vertical experiment, the choking velocity for 150-micron glass spheres was determined to be 1/2 to 1/3 the velocity required at 1 g. Pressure drops were reduced by roughly the same amount. Determination of the saltation velocity in the horizontal run was problematic, but qualitatively similar results were obtained. Comparison of the partial g results to 1-g behavior and theoretical analysis is made.

  13. Pneumatic Proboscis Heat-Flow Probe

    NASA Technical Reports Server (NTRS)

    Zacny, Kris; Hedlund, Magnus; Mumm, Eric; Shasho, Jeffrey; Chu, Philip; Kumar, Nishant

    2013-01-01

    Heat flow is a fundamental property of a planet, and provides significant constraints on the abundance of radiogenic isotopes, the thermal evolution and differentiation history, and the mechanical properties of the lithosphere. Heat-flow measurements are also essential in achieving at least four of the goals set out by the National Research Council for future lunar exploration. The heat-flow probe therefore directly addresses the goal of the Lunar Geophysical Network, which is to understand the interior structure and composition of the Moon. A key challenge for heat flow measurement is to install thermal sensors to the depths approximately equal to 3 m that are not influenced by the diurnal, annual, and longer-term fluctuations of the surface thermal environment. In addition, once deployed, the heat flow probe should cause little disturbance to the thermal regime of the surrounding regolith. A heat-flow probe system was developed that has two novel features: (1) it utilizes a pneumatic (gas) approach, excavates a hole by lofting the lunar soil out of the hole, and (2) deploys the heat flow probe, which utilizes a coiled up tape as a thermal probe to reach greater than 3-meter depth. The system is a game-changer for small lunar landers as it exhibits extremely low mass, volume, and simple deployment. The pneumatic system takes advantage of the helium gas used for pressurizing liquid propellant of the lander. Normally, helium is vented once the lander is on the surface, but it can be utilized for powering pneumatic systems. Should sufficient helium not be available, a simple gas delivery system may be taken specifically for the heat flow probe. Either way, the pneumatic heat flow probe system would be much lighter than other systems that entirely rely on the electrical power of the lander.

  14. Pneumatic preloaded scanning science launch latch system

    NASA Technical Reports Server (NTRS)

    Kievit, J. C.

    1979-01-01

    A relatively simple system using a preloaded pneumatic piston latch with a pyrotechnic valve release was developed. The system was the only candidate that met all the imposed requirements utilizing reliable state-of-art components. The development of the latch system from its first use on Mariner '69 Mars Flyby Spacecraft through its most recent use on the Voyager Spacecraft that will fly to Jupiter and Saturn is reviewed.

  15. Paranasal pneumatization in extant and fossil Cercopithecoidea.

    PubMed

    Rae, Todd C

    2008-03-01

    Unlike most primates, extant cercopithecoids lack maxillary sinuses, which are pneumatic spaces in the facial skeleton lateral of the nasal cavity proper. Character state analysis of living cercopithecoids across well-supported topologies suggests that the sinus was lost at the origin of the superfamily, only to have evolved again convergently in extant macaques. Recent work has shown that a) the 'early loss' hypothesis is supported by the lack of any pneumatization in Victoriapithecus, a stem cercopithecoid, b) like extant macaques, the fossil cercopithecine Paradolichopithecus shows evidence of presence of the maxillary sinus (MS), and c) unlike extant colobines, the fossil colobine Libypithecus also possesses a maxillary sinus. To more fully assess the pattern of cercopithecoid sinus evolution, fossil taxa from both subfamilies (Colobinae, Cercopithecinae) were examined both visually and by computed tomography (CT). The observations were evaluated according to standard anatomical criteria for defining sinus spaces, and compared with data from all extant Old World monkey genera. Most taxa examined conformed to the pattern already discerned from extant cercopithecoids. Maxillary sinus absence in Theropithecus oswaldi, Mesopithecus, and Rhinocolobus is typical for all extant cercopithecids except Macaca. The fossil macaque Macaca majori possesses a well-developed maxillary sinus, as do all living species of the genus. Cercopithecoides, on the other hand, differs from all extant colobines in possessing a maxillary sinus. Thus, paranasal pneumatization has reemerged a minimum of two and possibly three times in cercopithecoids. The results suggest that maxillary sinus absence in cercopithecoids is due to suppression, rather than complete loss.

  16. Pneumatic compression hemodynamics in total hip arthroplasty.

    PubMed

    Westrich, G H; Specht, L M; Sharrock, N E; Sculco, T P; Salvati, E A; Pellicci, P M; Trombley, J F; Peterson, M

    2000-03-01

    A crossover study was performed to evaluate the effect of several pneumatic compression devices and active dorsoplantar flexion in 10 patients who underwent total hip arthroplasty. Using the Acuson 128XP/10 duplex ultrasound unit with a 5-MHz linear array probe, peak venous velocity and venous volume were assessed above and below the greater saphenous vein and common femoral vein junction. A computer generated randomization table was used to determine the order of the test conditions. The pneumatic compression devices evaluated included two foot pumps, one foot and calf pump, one calf pump, and three calf and thigh pumps. Statistical analyses included analysis of variance and analysis of variance with covariance between devices and patients. The covariates tested were the baseline measurements and the order in which the devices were tested. Differences between devices relate in part to the frequency and rate of inflation and the location and type of compression. Pulsatile calf and foot and calf pneumatic compression with a rapid inflation time produced the greatest increase in peak venous velocity, whereas compression of the calf and thigh showed the greatest increase in venous volume. Because patient and nursing compliance is essential to the success of mechanical prophylaxis for thromboembolic disease, the more simple, yet efficacious, devices that are easier to apply and less cumbersome appear to have a greater likelihood of success. In the active and alert patient, active dorsoplantar flexion should be encouraged.

  17. Magnetism in metal-organic capsules

    SciTech Connect

    Atwood, Jerry L.; Brechin, Euan K; Dalgarno, Scott J.; Inglis, Ross; Jones, Leigh F.; Mossine, Andrew; Paterson, Martin J.; Power, Nicholas P.; Teat, Simon J.

    2010-01-07

    Nickel and cobalt seamed metal-organic capsules have been isolated and studied using structural, magnetic and computational approaches. Antiferromagnetic exchange in the Ni capsule results from coordination environments enforced by the capsule framework.

  18. Comparison of pneumatic dilation with pneumatic dilation plus botulinum toxin for treatment of achalasia.

    PubMed

    Bakhshipour, Alireza; Rabbani, Romina; Shirani, Shapoor; Soleimani, Hosein A S L; Mikaeli, Javad

    2010-01-01

    Among the therapeutic options for achalasia are pneumatic dilatation (PD), an appropriate long-term therapy, and botulinum toxin injection (BT) that is a relatively short-term therapy. This study aimed to compare therapeutic effect of repetitive pneumatic dilation with a combined method (botulinum toxin injection and pneumatic dilation) in a group of achalasia patients who are low responder to two initial pneumatic dilations. Thirty-four patients with documented primary achalasia that had low response to two times PD (<50% decrease in symptom score and barium height at 5 minute in timed esophagogram after 3 month of late PD) were randomized to receive pneumatic dilation (n=18) or botulinum toxin injection and pneumatic dilation by four weeks interval (n=16), PD and BT+PD groups respectively. Symptom scores were evaluated before and at 1, 6 and 12 months after treatment. Clinical remission was defined as a decrease in symptom score > or = 50% of baseline. There were no significant differences between the two groups in gender, age and achalasia type. Remission rate of patients in BT-PD group in comparison with PD group were 87.5% vs. 67.1% (P = 0.7), 87.5% vs. 61.1% (P = 0.59) and 87.5% vs. 55.5% (P = 0.53) at 1, 6 and 12 months respectively .There were no major complications in either group. The mean symptom score decreased by 62.71% in the BT-PD group (P < 0.002) and 50.77% in the PD group (P < 0.01) at the end of the first year. Despite a better response rate in BT+PD group, a difference was not statistically significant. A difference may be meaningful if a large numbers of patients are included in the study.

  19. Spacecraft Escape Capsule

    NASA Technical Reports Server (NTRS)

    Robertson, Edward A.; Charles, Dingell W.; Bufkin, Ann L.; Rodriggs, Liana M.; Peterson, Wayne; Cuthbert, Peter; Lee, David E.; Westhelle, Carlos

    2006-01-01

    A report discusses the Gumdrop capsule a conceptual spacecraft that would enable the crew to escape safely in the event of a major equipment failure at any time from launch through atmospheric re-entry. The scaleable Gumdrop capsule would comprise a command module (CM), a service module (SM), and a crew escape system (CES). The CM would contain a pressurized crew environment that would include avionic, life-support, thermal control, propulsive attitude control, and recovery systems. The SM would provide the primary propulsion and would also supply electrical power, life-support resources, and active thermal control to the CM. The CES would include a solid rocket motor, embedded within the SM, for pushing the CM away from the SM in the event of a critical thermal-protection-system failure or loss of control. The CM and SM would normally remain integrated with each other from launch through recovery, but could be separated using the CES, if necessary, to enable the safe recovery of the crew in the CM. The crew escape motor could be used, alternatively, as a redundant means of de-orbit propulsion for the CM in the event of a major system failure in the SM.

  20. 78 FR 41991 - Pipeline Safety: Potential for Damage to Pipeline Facilities Caused by Flooding

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-07-12

    ... Pipeline and Hazardous Materials Safety Administration Pipeline Safety: Potential for Damage to Pipeline Facilities Caused by Flooding AGENCY: Pipeline and Hazardous Materials Safety Administration (PHMSA); DOT... operators should contact the appropriate state pipeline safety authority. A list of state pipeline...

  1. 77 FR 34123 - Pipeline Safety: Public Meeting on Integrity Management of Gas Distribution Pipelines

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-06-08

    ... Pipeline and Hazardous Materials Safety Administration Pipeline Safety: Public Meeting on Integrity Management of Gas Distribution Pipelines AGENCY: Office of Pipeline Safety, Pipeline and Hazardous Materials Safety Administration, DOT. ACTION: Notice; public meeting. SUMMARY: The Pipeline and Hazardous...

  2. Impulse-driven Micromechanism Capsule

    NASA Astrophysics Data System (ADS)

    Ito, Takahiro; Ishimori, Shohei; Hayashi, Teru

    We have developed a traveling small capsule, which has a smooth outer surface and is driven by inertia force and friction force. Measuring only 7 mm in diameter and 12 mm in length, it is sufficiently small to be placed in the human gullet or intestines. The capsule contains a small magnet and a coil, and an electric pulse drives the magnet to move the capsule. We performed an experimental investigation on making our capsule travel on a plastic material, which has similar elasticity characteristics to the living body. We also showed that it can travel on the surface of a pig's intestine. Our capsule may be useful for medical treatments such as inspection, drug delivery and operation.

  3. Coal slurry pipelining

    SciTech Connect

    Chassagne, P.J.

    1980-02-05

    A method is disclosed for preparing industrial ores, e.g., coal, for pipelining and pipelining the ores to a site for subsequent processing or use. Ore from a mine is screened into two fractions, one having a large size particle distribution and one having a small size particle distribution, each fraction retaining both the ore and the refuse. The large size particle fraction is cleaned of refuse and the clean ore therefrom crushed to a size distribution of the smaller size or small size ore fraction. The separated refuse from the large size particle fraction is ground to provide superfines to the extent required for the proper particle size distribution for pipelining. The ore and superfine refuse are combined in a water slurry for pipelining. After pipelining the ore, the ore is cleaned and dewatered conveniently as known in the art for fine ore. The resulting ore may then be stockpiled or directly used.

  4. Design Optimization of Innovative High-Level Waste Pipeline Unplugging Technologies - 13341

    SciTech Connect

    Pribanic, T.; Awwad, A.; Varona, J.; McDaniel, D.; Gokaltun, S.; Crespo, J.

    2013-07-01

    Florida International University (FIU) is currently working on the development and optimization of two innovative pipeline unplugging methods: the asynchronous pulsing system (APS) and the peristaltic crawler system (PCS). Experiments were conducted on the APS to determine how air in the pipeline influences the system's performance as well as determine the effectiveness of air mitigation techniques in a pipeline. The results obtained during the experimental phase of the project, including data from pipeline pressure pulse tests along with air bubble compression tests are presented. Single-cycle pulse amplification caused by a fast-acting cylinder piston pump in 21.8, 30.5, and 43.6 m pipelines were evaluated. Experiments were conducted on fully flooded pipelines as well as pipelines that contained various amounts of air to evaluate the system's performance when air is present in the pipeline. Also presented are details of the improvements implemented to the third generation crawler system (PCS). The improvements include the redesign of the rims of the unit to accommodate a camera system that provides visual feedback of the conditions inside the pipeline. Visual feedback allows the crawler to be used as a pipeline unplugging and inspection tool. Tests conducted previously demonstrated a significant reduction of the crawler speed with increasing length of tether. Current improvements include the positioning of a pneumatic valve manifold system that is located in close proximity to the crawler, rendering tether length independent of crawler speed. Additional improvements to increase the crawler's speed were also investigated and presented. Descriptions of the test beds, which were designed to emulate possible scenarios present on the Department of Energy (DOE) pipelines, are presented. Finally, conclusions and recommendations for the systems are provided. (authors)

  5. GAS PIPELINE PIGABILITY

    SciTech Connect

    Ted Clark; Bruce Nestleroth

    2004-04-01

    In-line inspection equipment is commonly used to examine a large portion of the long distance transmission pipeline system that transports natural gas from well gathering points to local distribution companies. A piece of equipment that is inserted into a pipeline and driven by product flow is called a ''pig''. Using this term as a base, a set of terms has evolved. Pigs that are equipped with sensors and data recording devices are called ''intelligent pigs''. Pipelines that cannot be inspected using intelligent pigs are deemed ''unpigable''. But many factors affect the passage of a pig through a pipeline, or the ''pigability''. The pigability pipeline extend well beyond the basic need for a long round hole with a means to enter and exit. An accurate assessment of pigability includes consideration of pipeline length, attributes, pressure, flow rate, deformation, cleanliness, and other factors as well as the availability of inspection technology. All factors must be considered when assessing the appropriateness of ILI to assess specific pipeline threats.

  6. Pollution from pipelines

    SciTech Connect

    Not Available

    1991-01-01

    During the 1980s, over 3,900 spills from land-based pipelines released nearly 20 million gallons of oil into U.S. waters-almost twice as much as was released by the March 1989 Exxon Valdez oil spill. Although the Department of Transportation is responsible for preventing water pollution from petroleum pipelines, GAO found that it has not established a program to prevent such pollution. DOT has instead delegated this responsibility to the Coast Guard, which has a program to stop water pollution from ships, but not from pipelines. This paper reports that, in the absence of any federal program to prevent water pollution from pipelines, both the Coast Guard and the Environmental Protection Agency have taken steps to plan for and respond to oil spills, including those from pipelines, as required by the Clean Water Act. The Coast Guard cannot, however, adequately plan for or ensure a timely response to pipeline spills because it generally is unaware of specific locations and operators of pipelines.

  7. Web-Based Learning and Instruction Support System for Pneumatics

    ERIC Educational Resources Information Center

    Yen, Chiaming; Li, Wu-Jeng

    2003-01-01

    This research presents a Web-based learning and instructional system for Pneumatics. The system includes course material, remote data acquisition modules, and a pneumatic laboratory set. The course material is in the HTML format accompanied with text, still and animated images, simulation programs, and computer aided design tools. The data…

  8. An electromagnetic pneumatic blood pump driver.

    PubMed

    Whalen, R L; Briskman, R N

    1988-01-01

    An electromagnetic pneumatic pump driver has been developed with the goals of enhanced mechanical reliability and simplicity of operation. The new driver eliminates failure prone components such as solenoid valves or pressure regulators common to conventional pneumatic drive systems, has only a single moving part, and provides for closed-loop operation in which stroke volume and dP/dT are controlled on each beat in real time. Power is provided by a high force (178 N) electromagnetic linear actuator. This assembly uses a high energy density neodymium-iron-boron permanent magnet, low loss vanadium alloy pole pieces, and an energized moving coil. The nominal stroke length of the actuator is 1.7 cm. During operation, the moving coil always remains within a fixed annular air gap, resulting in a measured force output versus applied power linearity of better than 92% over its stroke range. The coil is directly attached to the free end of a 10 cm diameter, 21 convolution, welded titanium metal bellows that forms the gas containing element of the system. The comparatively low pressure gradients across the bellows in this application result in a predicted life for the bellows in excess of 10(9) cycles. Bellows position and internal pressure are monitored continuously to control the pneumatic output. The linear actuator total excursion and velocity are adjusted on each beat using a closed-loop servo system. This results in a pump driver with no operator required adjustment of drive pressure. Instead, there are user selected settings of stroke volume, operating mode, and fill sensitivity.(ABSTRACT TRUNCATED AT 250 WORDS)

  9. INTERNAL REPAIR OF PIPELINES

    SciTech Connect

    Robin Gordon; Bill Bruce; Nancy Porter; Mike Sullivan; Chris Neary

    2003-05-01

    The two broad categories of deposited weld metal repair and fiber-reinforced composite repair technologies were reviewed for potential application for internal repair of gas transmission pipelines. Both are used to some extent for other applications and could be further developed for internal, local, structural repair of gas transmission pipelines. Preliminary test programs were developed for both deposited weld metal repairs and for fiber-reinforced composite repair. To date, all of the experimental work pertaining to the evaluation of potential repair methods has focused on fiber-reinforced composite repairs. Hydrostatic testing was also conducted on four pipeline sections with simulated corrosion damage: two with composite liners and two without.

  10. Pneumatic tire-based piezoelectric power generation

    NASA Astrophysics Data System (ADS)

    Makki, Noaman; Pop-Iliev, Remon

    2011-03-01

    Plug-in Hybrid Electric Vehicles (PHEVs) and Extended Range Electric Vehicles (EREVs) currently mainly rely on Internal Combustion Engines (ICE) utilizing conventional fuels to recharge batteries in order to extend their range. Even though Piezo-based power generation devices have surfaced in recent years harvesting vibration energy, their output has only been sufficient to power up sensors and other such smaller devices. The permanent need for a cleaner power generation technique still remains. This paper investigates the possibility of using piezoceramics for power generation within the vehicle's wheel assembly by exploiting the rotational motion of the wheel and the continuously variable contact point between the pneumatic tire and the road.

  11. Revisiting Pneumatic Nail Gun Trigger Recommendations

    PubMed Central

    Albers, James; Lipscomb, Hester; Hudock, Stephen; Dement, John; Evanoff, Bradley; Fullen, Mark; Gillen, Matt; Kaskutas, Vicki; Nolan, James; Patterson, Dennis; Platner, James; Pompeii, Lisa; Schoenfisch, Ashley

    2015-01-01

    Summary Use of a pneumatic nail gun with a sequential actuation trigger (SAT) significantly diminishes the risk for acute traumatic injury compared to use of a contact actuation trigger (CAT) nail gun. A theoretically-based increased risk of work-related musculoskeletal disorders from use of a SAT nail gun, relative to CAT, appears unlikely and remains unproven. Based on current knowledge, the use of CAT nail guns cannot be justified as a safe alternative to SAT nail guns. This letter provides a perspective of ergonomists and occupational safety researchers recommending the use of the sequential actuation trigger for all nail gun tasks in the construction industry. PMID:26366020

  12. Revisiting Pneumatic Nail Gun Trigger Recommendations.

    PubMed

    Albers, James; Lowe, Brian; Lipscomb, Hester; Hudock, Stephen; Dement, John; Evanoff, Bradley; Fullen, Mark; Gillen, Matt; Kaskutas, Vicki; Nolan, James; Patterson, Dennis; Platner, James; Pompeii, Lisa; Schoenfisch, Ashley

    2015-03-01

    Use of a pneumatic nail gun with a sequential actuation trigger (SAT) significantly diminishes the risk for acute traumatic injury compared to use of a contact actuation trigger (CAT) nail gun. A theoretically-based increased risk of work-related musculoskeletal disorders from use of a SAT nail gun, relative to CAT, appears unlikely and remains unproven. Based on current knowledge, the use of CAT nail guns cannot be justified as a safe alternative to SAT nail guns. This letter provides a perspective of ergonomists and occupational safety researchers recommending the use of the sequential actuation trigger for all nail gun tasks in the construction industry.

  13. Pneumatic Artificial Muscle Actuation and Modeling

    NASA Astrophysics Data System (ADS)

    Leephakpreeda, Thananchai; Wickramatunge, Kanchana C.

    2009-10-01

    A Pneumatic Artificial Muscle (PAM) yields a natural muscle-like actuator with a high force to weight ratio, a soft and flexible structure, and adaptable compliance for a humanoid robot, rehabilitation and prosthetic appliances to the disabled, etc. To obtain optimum design and usage, the mechanical behavior of the PAM need to be understood. In this study, observations of experimental results reveal an empirical model for relations of physical variables, contraction and air pressure within the PAM, as compared to mechanical characteristics, such as stiffness or/and pulling forces of the PAM available now in market.

  14. A comparison between two pneumatic suspension architectures

    NASA Astrophysics Data System (ADS)

    Quaglia, G.; Scopesi, M.; Franco, W.

    2012-04-01

    The aim of this work is to assess and compare the mathematical models of two pneumatic suspension architectures and show how they can converge, after appropriate simplifications, to a general linear form. After making this model dimensionless, it will be used to study, with a transmissibility analysis, the behaviour of a mono-suspension (quarter-car model). Finally, an example of a design process will be shown to highlight the strengths and weaknesses of both architectures and to provide the reader with a practical design tool.

  15. Numerical investigation of influence on heat transfer characteristics to pneumatically conveyed dense phase flow by selecting models and boundary conditions

    NASA Astrophysics Data System (ADS)

    Zheng, Y.; Liu, Q.; Li, Y.

    2012-03-01

    Solids moving with a gas stream in a pipeline can be found in many industrial processes, such as power generation, chemical, pharmaceutical, food and commodity transfer processes. A mass flow rate of the solids is important characteristic that is often required to be measured (and controlled) to achieve efficient utilization of energy and raw materials in pneumatic conveying systems. The methods of measuring the mass flow rate of solids in a pneumatic pipeline can be divided into direct and indirect (inferential) measurements. A thermal solids' mass flow-meter, in principle, should ideally provide a direct measurement of solids flow rate, regardless of inhomogeneities in solids' distribution and environmental impacts. One key issue in developing a thermal solids' mass flow-meter is to characterize the heat transfer between the hot pipe wall and the gas-solids dense phase flow. The Eulerian continuum modeling with gas-solid two phases is the most common method for pneumatic transport. To model a gas-solid dense phase flow passing through a heated region, the gas phase is described as a continuous phase and the particles as the second phase. This study aims to describe the heat transfer characteristics between the hot wall and the gas-solids dense phase flow in pneumatic pipelines by modeling a turbulence gas-solid plug passing through the heated region which involves several actual and crucial issues: selections of interphase exchange coefficient, near-wall region functions and different wall surface temperatures. A sensitivity analysis was discussed to identify the influence on the heat transfer characteristics by selecting different interphase exchange coefficient models and different boundary conditions. Simulation results suggest that sensitivity analysis in the choice of models is very significant. The simulation results appear to show that a combination of choosing the Syamlal-O'Brien interphase exchange coefficient model and the standard k-ɛ model along with

  16. Influence of capsule shell composition on the performance indicators of hypromellose capsule in comparison to hard gelatin capsules.

    PubMed

    Al-Tabakha, Moawia M; Arida, Adi Issam; Fahelelbom, Khairi M S; Sadek, Bassem; Saeed, Dima Ahmed; Abu Jarad, Rami A; Jawadi, Jeevani

    2015-01-01

    The purpose of this study was to assess the in vitro performances of "vegetable" capsules in comparison to hard gelatin capsules in terms of shell weight variation, reaction to different humidity conditions, resistance to stress in the absence of moisture, powder leakage, disintegration and dissolution. Two types of capsules made of HPMC produced with (Capsule 2) or without (Capsule 3) a gelling agent and hard gelatin capsules (Capsule 1) were assessed. Shell weight variability was relatively low for all tested capsules shells. Although Capsule 1 had the highest moisture content under different humidity conditions, all capsule types were unable to protect the encapsulated hygroscopic polyvinylpyrrolidone (PVP) powder from surrounding humidity. The initial disintegration for all Capsule 1 occurred within 3 min, but for other types of capsules within 6 min (n = 18). Dissolution of acetaminophen was better when the deionized water (DIW) temperature increased from 32 to 42 °C in case of Capsule 1, but the effect of temperature was not significant for the other types of capsules. Acetaminphen dissolution from Capsule 1 was the fastest (i.e. >90% in 10 min) and independent of the media pH or contents unlike Capsule 2 which was influenced by the pH and dissolution medium contents. It is feasible to use hypromellose capsules shells with or without gelling agent for new lines of pharmaceutical products, however, there is a window for capsule shells manufacturing companies to improve the dissolution of their hypromellose capsules to match the conventional gelatin capsule shells and eventually replace them.

  17. Underground pipeline corrosion control

    SciTech Connect

    Gundry, R.D.

    1988-04-01

    In the past few years, the pipeline corrosion control industry has been shaken by several catastrophic pipeline failures attributed to corrosion. Reports of corrosion-related failures seem to be on the rise, and this has caused the industry to reassess the criteria for cathodic protection and the correct application of the criteria. The US Congress and many state legislatures are also asking questions about pipeline safety. Several pieces of legislation are proposed to improve pipeline safety. NACE Task Group T-10-1 is in the process of revising Standard RP0169. Field data have been solicited from industry and are being analyzed. The committee has reviewed an extensive compilation of articles written over the last 50 years to evaluate the existing document. The committee is also awaiting the issuance of an Interim Report from the American Gas Association on the effectiveness of the criteria. The report is to present data obtained from several field test sites from around the country.

  18. Rnnotator Assembly Pipeline

    SciTech Connect

    Martin, Jeff

    2010-06-03

    Jeff Martin of the DOE Joint Genome Institute discusses a de novo transcriptome assembly pipeline from short RNA-Seq reads on June 3, 2010 at the "Sequencing, Finishing, Analysis in the Future" meeting in Santa Fe, NM

  19. Orion Capsule Mockup is Dropped

    NASA Video Gallery

    An Orion capsule mockup is dropped from a plane 25,000 feet above the Arizona desert to test its parachute design. Orion will return to Earth at speeds faster than previous human spacecraft, and wi...

  20. Colombian export oil pipeline

    SciTech Connect

    Duncan, K. ); Enright, B. )

    1989-06-01

    The authors discuss how bringing crude oil to market often requires extraordinary determination and effort to overcome the obstacles of terrain and time. They describe a pipeline project on a 53-week suicide schedule to get oil across the Colombian Andes. After confronting setbacks, they completed a job that included 304 miles of pipeline, 497 miles of telecommunications and a major offshore terminal in only 47 weeks.

  1. Transforming insect electromyograms into pneumatic muscle control

    NASA Astrophysics Data System (ADS)

    Rutter, Brandon; Mu, Laiyong; Ritzmann, Roy; Quinn, Roger

    2006-05-01

    Robots can serve as hardware models for testing biological hypotheses. Both for this reason and to improve the state of the art of robotics, we strive to incorporate biological principles of insect locomotion into robotic designs. Previous research has resulted in a line of robots with leg designs based on walking and climbing movements of the cockroach Blaberus discoidalis. The current version, Robot V, uses muscle-like Braided Pneumatic Actuators (BPAs). In this paper, we use recorded electromyograms (EMGs) to drive robot joint motion. A muscle activation model was developed that transforms EMGs recorded from behaving cockroaches into appropriate commands for the robot. The transform is implemented by multiplying the EMG by an input gain thus generating an input pressure signal, which is used to drive a one-way closed loop pressure controller. The actuator then can be modeled as a capacitance with input rectification. The actuator exhaust valve is given a leak rate, making the transform a leaky integrator for air pressure, which drives the output force of the actuator. We find parameters of this transform by minimizing the difference between the robot motion produced and that observed in the cockroach. Although we have not reproduced full-amplitude cockroach motion using this robot, results from evaluation on reduced-amplitude cockroach angle data strongly suggest that braided pneumatic actuators can be used as part of a physical model of a biological system.

  2. Pneumatic load compensating or controlling system

    NASA Technical Reports Server (NTRS)

    Rogers, J. R. (Inventor)

    1975-01-01

    A pneumatic load compensating or controlling system for restraining a load with a predetermined force or applying a predetermined force to the load is described; it includes a source of pressurized air, a one-way pneumatic actuator operatively connected to a load, and a fluid conduit fluidically connecting the actuator with the source of pressurized air. The actuator is of the piston and cylinder type, and the end of the fluid conduit is connected to the upper or lower portion of the cylinder whereby the actuator alternatively and selectively restrains the load with a predetermined force or apply a predetermined force to the load. Pressure regulators are included within the system for variably selectively adjusting the pressurized fluid to predetermined values as desired or required; a pressure amplifier is included within the system for multiplying the pressurized values so as to achieve greater load forces. An accumulator is incorporated within the system as a failsafe operating mechanism, and visual and aural alarm devices, operatively associated with pressure detecting apparatus, readily indicate the proper or improper functioning of the system.

  3. Axial and appendicular pneumaticity in Archaeopteryx.

    PubMed Central

    Christiansen, P; Bonde, N

    2000-01-01

    From the time of its discovery in 1860 to this day Archaeopteryx has been essential to our understanding of avian evolution. Despite the great diversity of plesiomorphic avialan (sensu Gauthier 1986) taxa discovered within the last decade, Archaeopteryx remains the most basal avialan taxon. A very unusual feature of extant birds is their lung structure, in which air diverticulae penetrate the bones. This has previously been reported in Archaeopteryx as well, in the cervical vertebrae of the Berlin specimen and in an anterior thoracal vertebra of the Eichstätt specimen. This indicates the presence of a cervical air sac. We show that the London specimen also has pneumatized anterior thoracal vertebrae, and, thus, that this feature was present in the most archaic avialans, as the London and Eichstätt specimens are different species. Furthermore, the pelvis of the London specimen shows clear signs of the presence of an abdominal air sac, indicating that at least two of the five air sacs present in modern birds were also present in Archaeopteryx. Evidence of pubic pneumaticity was also found in the same position in some extant ratites. PMID:11197125

  4. Scaling of pneumatic digital logic circuits.

    PubMed

    Duncan, Philip N; Ahrar, Siavash; Hui, Elliot E

    2015-03-07

    The scaling of integrated circuits to smaller dimensions is critical for achieving increased system complexity and speed. Digital logic circuits composed of pneumatic microfluidic components have to this point been limited to a circuit density of 2-4 gates cm(-2), constraining the complexity of the digital systems that can be achieved. We explored the use of precision machining techniques to reduce the size of pneumatic valves and resistors, and to achieve more accurate and efficient placement of ports and vias. In this way, we attained an order of magnitude increase in circuit density, reaching as high as 36 gates cm(-2). A 12-bit binary counter circuit composed of 96 gates was realized in an area of 360 mm(2). The reduction in size also brought an order of magnitude increase in speed. The frequency of a 13-stage ring oscillator increased from 2.6 Hz to 22.1 Hz, and the maximum clock frequency of a binary counter increased from 1/3 Hz to 6 Hz.

  5. Virtual Astronomical Pipelines

    NASA Astrophysics Data System (ADS)

    Dave, R.; Protopapas, P.; Lehner, M.

    2007-10-01

    The sheer magnitude of databases and data rates in new surveys makes it hard to develop pipelines to enable both the analysis of data and the federation of these databases for correlation and followup. There is thus a compelling need to facilitate the creation and management of dynamic workflow pipelines that enable correlating data between separate, parallel streams; changing the workflow in response to an event; using the NVO to obtain additional needed information from databases; and modifying the observing program of a primary survey to follow-up a transient or moving object. This paper describes such a Virtual Astronomical Pipeline (VAP) system which is running in the TAOS project. The software enables components in the pipeline to react to events encapsulated in XML messages, modifying and subsequently routing these messages to multiple other components. This architecture allows for the bootstrapping of components individually in the development process and for dynamic reconfiguration of the pipeline as a response to external and internal events. The software will be extended for future work in combining the results of surveys and followups into a global virtual pipeline.

  6. Continued Development and Improvement of Pneumatic Heavy Vehicles

    SciTech Connect

    Robert J. Englar

    2005-07-15

    The objective of this applied research effort led by Georgia Tech Research Institute is the application of pneumatic aerodynamic technology previously developed and patented by us to the design of an appropriate Heavy Vehicle (HV) tractor-trailer configuration, and experimental confirmation of this pneumatic configuration's improved aerodynamic characteristics. In Phases I to IV of our previous DOE program (Reference 1), GTRI has developed, patented, wind-tunnel tested and road-tested blown aerodynamic devices for Pneumatic Heavy Vehicles (PHVs) and Pneumatic Sports Utility Vehicles (PSUVs). To further advance these pneumatic technologies towards HV and SUV applications, additional Phase V tasks were included in the first year of a continuing DOE program (Reference 2). Based on the results of the Phase IV full-scale test programs, these Phase V tasks extended the application of pneumatic aerodynamics to include: further economy and performance improvements; increased aerodynamic stability and control; and safety of operation of Pneumatic HVs. Continued development of a Pneumatic SUV was also conducted during the Phase V program. Phase V was completed in July, 2003; its positive results towards development and confirmation of this pneumatic technology are reported in References 3 and 4. The current Phase VI of this program was incrementally funded by DOE in order to continue this technology development towards a second fuel economy test on the Pneumatic Heavy Vehicle. The objectives of this current Phase VI research and development effort (Ref. 5) fall into two categories: (1) develop improved pneumatic aerodynamic technology and configurations on smaller-scale models of the advanced Pneumatic Heavy Vehicle (PHV); and based on these findings, (2) redesign, modify, and re-test the modified full-scale PHV test vehicle. This second objective includes conduct of an on-road preliminary road test of this configuration to prepare it for a second series of SAE Type-U fuel

  7. BENCAP, LLC: CAPSULE VELOCITY TEST

    SciTech Connect

    Meidinger, Brian

    2005-09-07

    Ben Cap, LLC, has a technology that utilizes bebtonite to plug wells. The bentonite is encapsulated in a cardboard capsule, droped down to the bottom of the well where it is allowed to hydrate, causing the bentonite to expand and plug the well. This method of plugging a well is accepted in some, but not all states. This technology can save a significant amount of money when compared to cementing methods currently used to plug and abandon wells. The test objective was to obtain the terminal velocity of the capsule delivery system as it drops through a column of water in a wellbore. Once the terminal velocity is known, the bentonite swelling action can be timed not to begin swelling until it reaches the bottom of the well bore. The results of the test showed that an average speed of 8.93 plus or minus 0.12 ft/sec was achieved by the capsule as it was falling through a column of water. Plotting the data revealed a very linear function with the capsules achieving terminal velocity shortly after being released. The interference of the capsule impacting the casing was not readily apparent in any of the runs, but a siginal sampling anomaly was present in one run. Because the anomaly was so brief and not present in any of the other runs, no solid conclusions could be drawn. Additional testing would be required to determine the effects of capsules impacting a fluid level that is not at surface.

  8. Contraindications for video capsule endoscopy

    PubMed Central

    Bandorski, Dirk; Kurniawan, Niehls; Baltes, Peter; Hoeltgen, Reinhard; Hecker, Matthias; Stunder, Dominik; Keuchel, Martin

    2016-01-01

    Video capsule endoscopy (VCE) has been applied in the last 15 years in an increasing field of applications. Although many contraindications have been put into perspective, some precautions still have to be considered. Known stenosis of the gastrointestinal tract is a clear contraindication for VCE unless surgery is already scheduled or at least has been considered as an optional treatment modality. In patients with a higher incidence of stenosis, as in an established diagnosis of Crohn’s disease, clinical signs of obstruction, prior radiation or surgical small bowel resection, a preceding test with the self-dissolving patency capsule can override this contraindication. Endoscopic placement of the capsule should be considered in patients with swallowing disorders to avoid aspiration. Esophageal or gastric motility disorders may require endoscopic capsule transport or application of prokinetics if the real-time viewer proofs delayed transit. In pregnant women, VCE should be restricted to urgent cases where diagnosis cannot be postponed after delivery, as data on safety are missing. There is theoretical and clinical evidence that patients with implanted cardiac devices such as a pacemaker, cardioverters or left heart assist devices, can safely undergo VCE in spite of still existing contraindication by manufacturers. Children from the age of 2 years have safely undergone VCE. Although video capsules are not proven safe with magnetic resonance imaging (MRI), first single cases of patients incidentally undergoing MRI with an incorporated capsule have been reported, showing susceptibility artifacts but no signs of clinical harm. PMID:28018097

  9. Compensating for pneumatic distortion in pressure sensing devices

    NASA Technical Reports Server (NTRS)

    Whitmore, Stephen A.; Leondes, Cornelius T.

    1990-01-01

    A technique of compensating for pneumatic distortion in pressure sensing devices was developed and verified. This compensation allows conventional pressure sensing technology to obtain improved unsteady pressure measurements. Pressure distortion caused by frictional attenuation and pneumatic resonance within the sensing system makes obtaining unsteady pressure measurements by conventional sensors difficult. Most distortion occurs within the pneumatic tubing which transmits pressure impulses from the aircraft's surface to the measurement transducer. To avoid pneumatic distortion, experiment designers mount the pressure sensor at the surface of the aircraft, (called in-situ mounting). In-situ transducers cannot always fit in the available space and sometimes pneumatic tubing must be run from the aircraft's surface to the pressure transducer. A technique to measure unsteady pressure data using conventional pressure sensing technology was developed. A pneumatic distortion model is reduced to a low-order, state-variable model retaining most of the dynamic characteristics of the full model. The reduced-order model is coupled with results from minimum variance estimation theory to develop an algorithm to compensate for the effects of pneumatic distortion. Both postflight and real-time algorithms are developed and evaluated using simulated and flight data.

  10. Pneumatization degree of the anterior clinoid process: a new classification.

    PubMed

    Abuzayed, Bashar; Tanriover, Necmettin; Biceroglu, Huseyin; Yuksel, Odhan; Tanriover, Ozlem; Albayram, Sait; Akar, Ziya

    2010-07-01

    The objective of this study is to determine the incidence and degree of anterior clinoid process pneumatization, in addition highlighting to their clinical significance. Multidetector-row CT scans of the skull base were reviewed in 648 subjects between 2007 and 2008. The presence of pneumatized anterior clinoid process and its degree were studied and documented. These data were statistically analyzed. Pneumatization of the ACP was found in 62 of 648 patients (9.6%) including 32 (51.6%) men and 30 (48.4%) women. The age of these patients ranged from 21 to 82 years (mean, 41 +/- 15.7 years). Pneumatization of the ACP occurred only on the left side in 14 cases (22.6%), only on the right side in 11 cases (17.7%), and bilaterally in 37 patients (59.7%). ACP pneumatization Type I, in which less than 50% of the ACP is pneumatized, was found in 47 of 124 sides (38%), Type II, in which more than 50% but not totally pneumatized ACP, was found in 28 of 124 sides (22.6%), and Type III, in which the ACP is totally pneumatized, was found in 22 of 124 sides (17.7%). The incidence of Type I in the general population was 6.6%, Type II was 3.5%, and Type III was 2.5%. Radiologically recognizing the degree of ACP pneumatization is important in decreasing the incidence of surgical complications during anterior clinoidectomy. Proper intraoperative management can be undertaken with special attention to the new classification.

  11. Hazard of electrostatic generation in a pneumatic conveying system: electrostatic effects on the accuracy of electrical capacitance tomography measurements and generation of spark

    NASA Astrophysics Data System (ADS)

    Zhang, Yan; Chii Liang, Yung; Wang, Chi-Hwa

    2008-01-01

    The study of the hazard of electrostatic generation in pneumatic conveying systems was attempted by examining the sensitivity of electrical capacitance tomography (ECT) and the phenomena of spark generation due to strong electrostatics. The influence on ECT measurement accuracy of an electrostatic charge was analysed with reference to a switch capacitor configuration model. Consequently, it was found that the electrostatic charge introduced at the bend with sharp angles influenced the ECT results most significantly in pneumatic conveying systems, especially for the cases where a spark was generated. The investigation of spark generation indicated that a strong electrostatic charge can cause major discharges inside or outside the pipeline to damage the experimental instrument in severe cases.

  12. 75 FR 45591 - Pipeline Safety: Notice of Technical Pipeline Safety Advisory Committee Meetings

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-08-03

    ... Pipeline and Hazardous Materials Safety Administration 49 CFR Part 192 Pipeline Safety: Notice of Technical Pipeline Safety Advisory Committee Meetings AGENCY: Pipeline and Hazardous Materials Safety Administration (PHMSA); DOT. ACTION: Notice of technical pipeline safety advisory committee meetings. SUMMARY:...

  13. 77 FR 2126 - Pipeline Safety: Implementation of the National Registry of Pipeline and Liquefied Natural Gas...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-01-13

    ... Registry of Pipeline and Liquefied Natural Gas Operators AGENCY: Pipeline and Hazardous Materials Safety... registry of pipeline and liquefied natural gas operators. FOR FURTHER INFORMATION CONTACT: Jamerson Pender... 72878), titled: ``Pipeline Safety: Updates to Pipeline and Liquefied Natural Gas Reporting...

  14. Summary Report for Capsule Dry Storage Project

    SciTech Connect

    JOSEPHSON, W S

    2003-09-04

    There are 1.936 cesium (Cs) and strontium (Sr) capsules stored in pools at the Waste Encapsulation and Storage Facility (WESF). These capsules will be moved to dry storage on the Hanford Site as an interim measure to reduce risk. The Cs/Sr Capsule Dry Storage Project (CDSP) is conducted under the assumption the capsules will eventually be moved to the repository at Yucca Mountain, and the design criteria include requirements that will facilitate acceptance at the repository. The storage system must also permit retrieval of capsules in the event vitrification of the capsule contents is pursued. A cut away drawing of a typical cesium chloride (CsCI) capsule and the capsule property and geometry information are provided in Figure 1.1. Strontium fluoride (SrF{sub 2}) capsules are similar in design to CsCl capsules. Further details of capsule design, current state, and reference information are given later in this report and its references. Capsule production and life history is covered in WMP-16938, Capsule Characterization Report for Capsule Dry Storage Project, and is briefly summarized in Section 5.2 of this report.

  15. 75 FR 13342 - Pipeline Safety: Workshop on Distribution Pipeline Construction

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-03-19

    ... practices in natural gas distribution pipeline construction management and quality control. This workshop... to inspection findings. (2) Distribution materials, Quality Assurance/Quality Control, related best... Construction AGENCY: Pipeline and Hazardous Materials Safety Administration (PHMSA), DOT. ACTION: Notice...

  16. 77 FR 31827 - Pipeline Safety: Pipeline Damage Prevention Programs

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-05-30

    ... Safety: Pipeline Damage Prevention Programs AGENCY: Pipeline and Hazardous Materials Safety... excavation damage prevention law enforcement programs; establish an administrative process for making... excavation damage prevention law enforcement programs; and establish the adjudication process...

  17. Optimizing pneumatic conveying of biomass materials

    NASA Astrophysics Data System (ADS)

    DiCianni, Matthew Edward Michael

    2011-12-01

    Biomass is a readily available but underutilized energy resource. One of the main challenges is the inability of biomass feed stocks like corn stover or wood chips to flow freely without intermittent jamming. This research integrated an automated pneumatic conveying system to efficiently transport biomass into a biomass reactor. Material was held in a storage container until an end effector attached to a 3-axis controller engaged the material to flow through pneumatic vacuum in the carrier fluid of air. The material was disengaged from the carrier fluid through centripetal forces induced by a cyclone separator. As the air was pulled out of the cyclone, the biomass drops out the bottom due to gravitational forces and fell into a secondary storage hopper. The second storage container was for testing purposes only, where the actual apparatus would use a vertically oriented lock hopper to feed material into the biomass reactor. In the experimental test apparatus, sensors measured the storage hopper weight (mass-flow rate), pressure drop from the blower, and input power consumption of the motor. Parameters that were adjusted during testing include pipe diameter, material type, and motor speed. Testing indicated that decreasing the motor speed below its maximum still allows for conveyance of the material without blockage forming in the piping. The data shows that the power consumption of the system can be reduced based on the size and weight of the material introduced to the conveying pipe. Also, conveying certain materials proved to be problematic with particular duct diameters. Ultimately, an optimal duct diameter that can perform efficiently for a broad range of materials was chosen for the given system. Through these improvements, the energy return on investment will be improved for biomass feed stocks, which is taking a step in the right direction to secure the nation's energy independence.

  18. Coal log pipeline research at University of Missouri. 1. quarterly report for 1996, January 1--March 31, 1996

    SciTech Connect

    1996-07-01

    This project consists of the following nine tasks: Machine design for coal log fabrication; Very rapid compaction of coal logs; Rapid compaction of coal logs; Fast-track experiments on coal log compaction; Coal log fabrication using hydrophobic binders; Drag reduction in large diameter hydraulic capsule pipeline; Automatic control of coal log pipeline system; Hydraulics of CLP (Coal Log Pipeline); and Coal heating system research. The purpose of the task, the work accomplished during this report period, and work proposed for the next quarter are described for each task.

  19. Spot-Welding Gun With Adjustable Pneumatic Spring

    NASA Technical Reports Server (NTRS)

    Burley, Richard K.

    1990-01-01

    Proposed spot-welding gun equipped with pneumatic spring, which could be bellows or piston and cylinder, exerts force independent of position along stroke. Applies accurate controlled force to joint welded, without precise positioning at critical position within stroke.

  20. TOPICAL REVIEW: Pneumatic and hydraulic microactuators: a review

    NASA Astrophysics Data System (ADS)

    De Volder, Michaël; Reynaerts, Dominiek

    2010-04-01

    The development of MEMS actuators is rapidly evolving and continuously new progress in terms of efficiency, power and force output is reported. Pneumatic and hydraulic are an interesting class of microactuators that are easily overlooked. Despite the 20 years of research, and hundreds of publications on this topic, these actuators are only popular in microfluidic systems. In other MEMS applications, pneumatic and hydraulic actuators are rare in comparison with electrostatic, thermal or piezo-electric actuators. However, several studies have shown that hydraulic and pneumatic actuators deliver among the highest force and power densities at microscale. It is believed that this asset is particularly important in modern industrial and medical microsystems, and therefore, pneumatic and hydraulic actuators could start playing an increasingly important role. This paper shows an in-depth overview of the developments in this field ranging from the classic inflatable membrane actuators to more complex piston-cylinder and drag-based microdevices.

  1. PNEUMATICALLY CLEANING TOP HALF OF LARGE MOLD IN BOX FLOOR ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    PNEUMATICALLY CLEANING TOP HALF OF LARGE MOLD IN BOX FLOOR AREA TO REMOVE ANY EXCESS OR LOOSE SAND. - Stockham Pipe & Fittings Company, Ductile Iron Foundry, 4000 Tenth Avenue North, Birmingham, Jefferson County, AL

  2. 23. CORE WORKER OPERATING A COREBLOWER THAT PNEUMATICALLY FILLED CORE ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    23. CORE WORKER OPERATING A CORE-BLOWER THAT PNEUMATICALLY FILLED CORE BOXES WITH RESIGN IMPREGNATED SAND AND CREATED A CORE THAT THEN REQUIRED BAKING, CA. 1950. - Stockham Pipe & Fittings Company, 4000 Tenth Avenue North, Birmingham, Jefferson County, AL

  3. Microfluidic pressure amplifier circuits and electrostatic gates for pneumatic microsystems

    SciTech Connect

    Tice, Joshua D.; Bassett, Thomas A.; Desai, Amit V.; Apblett, Christopher A.; Kenis, Paul J. A.

    2016-09-20

    An electrostatic actuator is provide that can include a fluidic line, a first electrode, and a second electrode such that a gate chamber portion of the fluidic line is sandwiched between the first electrode and the second electrode. The electrostatic actuator can also include a pressure-balancing channel in fluid communication with the gate chamber portion where the first electrode is sandwiched between the pressure-balancing channel and the gate chamber portion. A pneumatic valve system is provided which includes an electrostatic gate and a fluidic channel fluidly separate from a fluidic control line. A pneumatic valve portion of the fluidic control line can be positioned relative to a portion of the fluidic channel such that expansion of the pneumatic valve portion restricts fluid flow through the fluidic channel. Methods of using an electrostatic actuator and a pneumatic valve system are also provided.

  4. Detail, north end of console and pneumatic tube message port, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Detail, north end of console and pneumatic tube message port, also showing mirror to reflect view of communications switchboard - March Air Force Base, Strategic Air Command, Combat Operations Center, 5220 Riverside Drive, Moreno Valley, Riverside County, CA

  5. Inline evenflow material distributor for pneumatic material feed systems

    DOEpatents

    Thiry, Michael J.

    2007-02-20

    An apparatus for reducing clogs in a pneumatic material feed line, such as employed in abrasive waterjet machining systems, by providing an evenflow feed of material therethrough. The apparatus preferably includes a hollow housing defining a housing volume and having an inlet capable of connecting to an upstream portion of the pneumatic material feed line, an outlet capable of connecting to a downstream portion of the pneumatic material feed line, and an air vent located between the inlet and outlet for venting excess air pressure out from the housing volume. A diverter, i.e. an impingement object, is located at the inlet and in a path of incoming material from the upstream portion of the pneumatic material feed line, to break up clumps of ambient moisture-ridden material impinging on the diverter. And one or more filter screens is also preferably located in the housing volume to further break up clumps and provide filtering.

  6. Analytical Solution to the Pneumatic Transient Rod System at ACRR

    SciTech Connect

    Fehr, Brandon Michael

    2016-01-08

    The ACRR pulse is pneumatically driven by nitrogen in a system of pipes, valves and hoses up to the connection of the pneumatic system and mechanical linkages of the transient rod (TR). The main components of the TR pneumatic system are the regulator, accumulator, solenoid valve and piston-cylinder assembly. The purpose of this analysis is to analyze the flow of nitrogen through the TR pneumatic system in order to develop a motion profile of the piston during the pulse and be able to predict the pressure distributions inside both the cylinder and accumulators. The predicted pressure distributions will be validated against pressure transducer data, while the motion profile will be compared to proximity switch data. By predicting the motion of the piston, pulse timing will be determined and provided to the engineers/operators for verification. The motion profile will provide an acceleration distribution to be used in Razorback to more accurately predict reactivity insertion into the system.

  7. Pneumatic Regolith Transfer Systems for In Situ Resource Utilization

    NASA Technical Reports Server (NTRS)

    Mueller, R. P.; Townsend, I. I.; Mantovani, J. G.; Zacny, Kris A.; Craft, Jack

    2010-01-01

    This slide presentation reviews the testing of a pneumatic system for transfering regolith, to be used for In Situ Resource Utilization (ISRU). Using both the simulated microgravity of parabolic flight and ground testing, the tests demonstrated that lunar regolith can be conveyed pneumatically into a simulated ISRU oxygen production plant reactor. The ground testing also demonstrated that the regolith can be expelled from the ISRU reactor for disposal or for other resource processing.

  8. PID control of gas pipelines

    SciTech Connect

    Coltharp, B.; Bergmann, J.

    1996-09-01

    The use of low cost digital controllers for pipeline control is increasing as the reliability and cost improves. In pipeline applications, the proportional, integral, and derivative (PID) controller algorithm is often used. However, the unique problems associated with pipeline operation have caused manufacturers to modify the basic control algorithms. Features such as set point ramping, built in pressure control, freeze on input error, and high and low output limits help assure safe and predictable pipeline operation.

  9. Triggered Release from Polymer Capsules

    SciTech Connect

    Esser-Kahn, Aaron P.; Odom, Susan A.; Sottos, Nancy R.; White, Scott R.; Moore, Jeffrey S.

    2011-07-06

    Stimuli-responsive capsules are of interest in drug delivery, fragrance release, food preservation, and self-healing materials. Many methods are used to trigger the release of encapsulated contents. Here we highlight mechanisms for the controlled release of encapsulated cargo that utilize chemical reactions occurring in solid polymeric shell walls. Triggering mechanisms responsible for covalent bond cleavage that result in the release of capsule contents include chemical, biological, light, thermal, magnetic, and electrical stimuli. We present methods for encapsulation and release, triggering methods, and mechanisms and conclude with our opinions on interesting obstacles for chemically induced activation with relevance for controlled release.

  10. Glenn Enters his Mercury Capsule

    NASA Technical Reports Server (NTRS)

    1962-01-01

    Astronaut John H. Glenn Jr. enters his Mercury capsule, 'Friendship 7' as he prepares for launch of the Mercury-Atlas rocket. On February 20, 1962 Glenn lifted off into space aboard his Mercury Atlas 6 (MA-6) rocket and became the first American to orbit the Earth. After orbiting the Earth 3 times, Friendship 7 landed in the Atlantic Ocean 4 hours, 55 minutes and 23 seconds later, just East of Grand Turk Island in the Bahamas. Glenn and his capsule were recovered by the Navy Destroyer Noa, 21 minutes after splashdown.

  11. Development of pneumatic actuator with low-wave reflection characteristics

    NASA Astrophysics Data System (ADS)

    Chang, H.; Tsung, T. T.; Jwo, C. S.; Chiang, J. C.

    2010-08-01

    This study aims at the development of a less reflective electromagnetic pneumatic actuator often used in the anechoic chamber. Because a pneumatic actuator on the market is not appropriate for use in such a chamber and a metallic one has high dielectric constant which generates reflective electromagnetic waves to influence test parameters in the chamber. The newly developed pneumatic actuator is made from low dielectric constant plastics with less reflective of electromagnetic. A turbine-type air motor is used to develop the pneumatic actuator and a employ Prony tester is used to run the brake horsepower test for the performance test of pneumatic actuator. Test results indicate that the pneumatic actuator in the minimal starting flow is 17 l/min, and it generates a brake horsepower of 48 mW; in the maximum flow is 26 l/min, it generates a brake horsepower of 108 mW. Therefore, it works with a torque between 0.24 N-m and 0.55 N-m, and such a torque will be sufficient to drive the target button.

  12. A New Type of Motor: Pneumatic Step Motor

    PubMed Central

    Stoianovici, Dan; Patriciu, Alexandru; Petrisor, Doru; Mazilu, Dumitru; Kavoussi, Louis

    2011-01-01

    This paper presents a new type of pneumatic motor, a pneumatic step motor (PneuStep). Directional rotary motion of discrete displacement is achieved by sequentially pressurizing the three ports of the motor. Pulsed pressure waves are generated by a remote pneumatic distributor. The motor assembly includes a motor, gearhead, and incremental position encoder in a compact, central bore construction. A special electronic driver is used to control the new motor with electric stepper indexers and standard motion control cards. The motor accepts open-loop step operation as well as closed-loop control with position feedback from the enclosed sensor. A special control feature is implemented to adapt classic control algorithms to the new motor, and is experimentally validated. The speed performance of the motor degrades with the length of the pneumatic hoses between the distributor and motor. Experimental results are presented to reveal this behavior and set the expectation level. Nevertheless, the stepper achieves easily controllable precise motion unlike other pneumatic motors. The motor was designed to be compatible with magnetic resonance medical imaging equipment, for actuating an image-guided intervention robot, for medical applications. For this reason, the motors were entirely made of nonmagnetic and dielectric materials such as plastics, ceramics, and rubbers. Encoding was performed with fiber optics, so that the motors are electricity free, exclusively using pressure and light. PneuStep is readily applicable to other pneumatic or hydraulic precision-motion applications. PMID:21528106

  13. UQ Pipeline Lorenz Portlet

    SciTech Connect

    2012-08-31

    This is web client software that can help initiate UQ Pipeline jobs on LLNL's LC compute systems and visually shows the status of such jobs in a browser window. The web client interacts with LC's interactive compute nodes using (LLNL) Lorenz REST API to initiate action and obtain status data in JSON format.

  14. Sensor capsule for diagnosis of gastric disorders

    NASA Technical Reports Server (NTRS)

    Holen, J. T.

    1972-01-01

    Motility and pH sensor capsule is developed to monitor gastric acidity, pressure, and temperature. Capsule does not interfere with digestion. Sensor is capsule which includes pH electrode, Pitran pressure transducer, and thermistor temperature sensor all potted in epoxy and enclosed in high density polyethylene sheath.

  15. Orchestrator Telemetry Processing Pipeline

    NASA Technical Reports Server (NTRS)

    Powell, Mark; Mittman, David; Joswig, Joseph; Crockett, Thomas; Norris, Jeffrey

    2008-01-01

    Orchestrator is a software application infrastructure for telemetry monitoring, logging, processing, and distribution. The architecture has been applied to support operations of a variety of planetary rovers. Built in Java with the Eclipse Rich Client Platform, Orchestrator can run on most commonly used operating systems. The pipeline supports configurable parallel processing that can significantly reduce the time needed to process a large volume of data products. Processors in the pipeline implement a simple Java interface and declare their required input from upstream processors. Orchestrator is programmatically constructed by specifying a list of Java processor classes that are initiated at runtime to form the pipeline. Input dependencies are checked at runtime. Fault tolerance can be configured to attempt continuation of processing in the event of an error or failed input dependency if possible, or to abort further processing when an error is detected. This innovation also provides support for Java Message Service broadcasts of telemetry objects to clients and provides a file system and relational database logging of telemetry. Orchestrator supports remote monitoring and control of the pipeline using browser-based JMX controls and provides several integration paths for pre-compiled legacy data processors. At the time of this reporting, the Orchestrator architecture has been used by four NASA customers to build telemetry pipelines to support field operations. Example applications include high-volume stereo image capture and processing, simultaneous data monitoring and logging from multiple vehicles. Example telemetry processors used in field test operations support include vehicle position, attitude, articulation, GPS location, power, and stereo images.

  16. Osmotic buckling of spherical capsules.

    PubMed

    Knoche, Sebastian; Kierfeld, Jan

    2014-11-07

    We study the buckling of elastic spherical shells under osmotic pressure with the osmolyte concentration of the exterior solution as a control parameter. We compare our results for the bifurcation behavior with results for buckling under mechanical pressure control, that is, with an empty capsule interior. We find striking differences for the buckling states between osmotic and mechanical buckling. Mechanical pressure control always leads to fully collapsed states with opposite sides in contact, whereas uncollapsed states with a single finite dimple are generic for osmotic pressure control. For sufficiently large interior osmolyte concentrations, osmotic pressure control is qualitatively similar to buckling under volume control with the volume prescribed by the osmolyte concentrations inside and outside the shell. We present a quantitative theory which also captures the influence of shell elasticity on the relationship between osmotic pressure and volume. These findings are relevant for the control of buckled shapes in applications. We show how the osmolyte concentration can be used to control the volume of buckled shells. An accurate analytical formula is derived for the relationship between the osmotic pressure, the elastic moduli and the volume of buckled capsules. This also allows use of elastic capsules as osmotic pressure sensors or deduction of elastic properties and the internal osmolyte concentration from shape changes in response to osmotic pressure changes. We apply our findings to published experimental data on polyelectrolyte capsules.

  17. The NOAO Pipeline Data Manager

    NASA Astrophysics Data System (ADS)

    Hiriart, R.; Valdes, F.; Pierfederici, F.; Smith, C.; Miller, M.

    2004-07-01

    The Data Manager for NOAO Pipeline system is a set of interrelated components that are being developed to fulfill the pipeline system data needs. It includes: (1) management of calibration files (flat, bias, bad pixel mask and xtalk calibration data.); (2) management of the pipeline stages' configuration parameters; and (3) management of the pipeline processing historic information, for each of the data products generated by the pipeline. The Data Manager components uses a distributed, CORBA based architecture, providing a flexible and extensible object oriented framework, capable of accommodating the present and future pipeline data requirements. The Data Manager communicates with the pipeline modules, with internal and external databases, and with other NOAO systems such as the NOAO Archive and the NOAO Data Transport System.

  18. Stress analysis of vibrating pipelines

    NASA Astrophysics Data System (ADS)

    Zachwieja, Janusz

    2017-03-01

    The pipelines are subject to various constraints variable in time. Those vibrations, if not monitored for amplitude and frequency, may result in both the fatigue damage in the pipeline profile at high stress concentration and the damage to the pipeline supports. If the constraint forces are known, the system response may be determined with high accuracy using analytical or numerical methods. In most cases, it may be difficult to determine the constraint parameters, since the industrial pipeline vibrations occur due to the dynamic effects of the medium in the pipeline. In that case, a vibration analysis is a suitable alternative method to determine the stress strain state in the pipeline profile. Monitoring the pipeline vibration levels involves a comparison between the measured vibration parameters and the permissible values as depicted in the graphs for a specific pipeline type. Unfortunately, in most cases, the studies relate to the petrochemical industry and thus large diameter, long and straight pipelines. For a pipeline section supported on both ends, the response in any profile at the entire section length can be determined by measuring the vibration parameters at two different profiles between the pipeline supports. For a straight pipeline section, the bending moments, variable in time, at the ends of the analysed section are a source of the pipe excitation. If a straight pipe section supported on both ends is excited by the bending moments in the support profile, the starting point for the stress analysis are the strains, determined from the Euler-Bernoulli equation. In practice, it is easier to determine the displacement using the experimental methods, since the factors causing vibrations are unknown. The industrial system pipelines, unlike the transfer pipelines, are straight sections at some points only, which makes it more difficult to formulate the equation of motion. In those cases, numerical methods can be used to determine stresses using the

  19. Differential staining of bacteria: capsule stain.

    PubMed

    Breakwell, Donald P; Moyes, Rita B; Reynolds, Jackie

    2009-11-01

    Bacterial capsules are composed of high-molecular-weight polysaccharides and/or polypeptides, and are associated with virulence and biofilm formation. Unfortunately, capsules do not stain well with crystal violet, methylene blue, or other simple stains. This unit describes two methods of capsule staining. The first is a wet-mount method using india ink; the capsule is visualized as a refractile zone surrounding a cell. The second is a direct-staining dry-mount method that precipitates copper sulfate and leaves the capsule as a pale blue zone. Both methods are easily performed within approximately 5 min.

  20. Design of flat pneumatic artificial muscles

    NASA Astrophysics Data System (ADS)

    Wirekoh, Jackson; Park, Yong-Lae

    2017-03-01

    Pneumatic artificial muscles (PAMs) have gained wide use in the field of robotics due to their ability to generate linear forces and motions with a simple mechanism, while remaining lightweight and compact. However, PAMs are limited by their traditional cylindrical form factors, which must increase radially to improve contraction force generation. Additionally, this form factor results in overly complicated fabrication processes when embedded fibers and sensor elements are required to provide efficient actuation and control of the PAMs while minimizing the bulkiness of the overall robotic system. In order to overcome these limitations, a flat two-dimensional PAM capable of being fabricated using a simple layered manufacturing process was created. Furthermore, a theoretical model was developed using Von Karman’s formulation for large deformations and the energy methods. Experimental characterizations of two different types of PAMs, a single-cell unit and a multi-cell unit, were performed to measure the maximum contraction lengths and forces at input pressures ranging from 0 to 150 kPa. Experimental data were then used to verify the fidelity of the theoretical model.

  1. Instrumented Pipeline Initiative

    SciTech Connect

    Thomas Piro; Michael Ream

    2010-07-31

    This report summarizes technical progress achieved during the cooperative agreement between Concurrent Technologies Corporation (CTC) and U.S. Department of Energy to address the need for a for low-cost monitoring and inspection sensor system as identified in the Department of Energy (DOE) National Gas Infrastructure Research & Development (R&D) Delivery Reliability Program Roadmap.. The Instrumented Pipeline Initiative (IPI) achieved the objective by researching technologies for the monitoring of pipeline delivery integrity, through a ubiquitous network of sensors and controllers to detect and diagnose incipient defects, leaks, and failures. This report is organized by tasks as detailed in the Statement of Project Objectives (SOPO). The sections all state the objective and approach before detailing results of work.

  2. Pipeline corridors through wetlands

    SciTech Connect

    Zimmerman, R.E.; Wilkey, P.L.; Isaacson, H.R.

    1992-12-01

    This paper presents preliminary findings from six vegetational surveys of gas pipeline rights-of-way (ROW) through wetlands and quantifies the impacts of a 20-year-old pipeline ROW through a boreal forest wetland. Six sites of various ages were surveyed in ecosystems ranging from coastal marsh to forested wetland. At all sites except one, both the number and the percentage of wetland species on the Row approximated or exceeded those in the adjacent natural area. The boreal forest study showed that (1) adjacent natural wetland areas were not altered in type; (2) water sheet flow restriction had been reversed by nature; (3) no nonnative plant species invaded the natural area; (4) three-quarters of the ROW area was a wetland, and (5) the ROW increased diversity.

  3. Pipeline Calibration for STIS

    NASA Astrophysics Data System (ADS)

    Hodge, P. E.; Hulbert, S. J.; Lindler, D.; Busko, I.; Hsu, J.-C.; Baum, S.; McGrath, M.; Goudfrooij, P.; Shaw, R.; Katsanis, R.; Keener, S.; Bohlin, R.

    The CALSTIS program for calibration of Space Telescope Imaging Spectrograph data in the OPUS pipeline differs in several significant ways from calibration for earlier HST instruments, such as the use of FITS format, computation of error estimates, and association of related exposures. Several steps are now done in the pipeline that previously had to be done off-line by the user, such as cosmic ray rejection and extraction of 1-D spectra. Although the program is linked with IRAF for image and table I/O, it is written in ANSI C rather than SPP, which should make the code more accessible. FITS extension I/O makes use of the new IRAF FITS kernel for images and the HEASARC FITSIO package for tables.

  4. Pipeline corridors through wetlands

    SciTech Connect

    Zimmerman, R.E.; Wilkey, P.L. ); Isaacson, H.R. )

    1992-01-01

    This paper presents preliminary findings from six vegetational surveys of gas pipeline rights-of-way (ROW) through wetlands and quantifies the impacts of a 20-year-old pipeline ROW through a boreal forest wetland. Six sites of various ages were surveyed in ecosystems ranging from coastal marsh to forested wetland. At all sites except one, both the number and the percentage of wetland species on the Row approximated or exceeded those in the adjacent natural area. The boreal forest study showed that (1) adjacent natural wetland areas were not altered in type; (2) water sheet flow restriction had been reversed by nature; (3) no nonnative plant species invaded the natural area; (4) three-quarters of the ROW area was a wetland, and (5) the ROW increased diversity.

  5. Pneumatic distortion compensation for aircraft surface pressure sensing devices

    NASA Technical Reports Server (NTRS)

    Whitmore, Stephen A.; Leondes, Cornelius T.

    1991-01-01

    In this paper a technique of compensating for pneumatic distortion in aircraft surface pressure sensing devices is developed. The compensation allows conventional pressure sensing technology to obtain improved unsteady pressure measurements. Pressure distortion caused by frictional attenuation and pneumatic resonance within the sensing system makes obtaining unsteady pressure measurements by conventional sensors difficult. Typically, most of the distortion occurs within the pneumatic tubing used to transmit pressure impulses from the surface of the aircraft to the measurement transducer. This paper develops a second-order distortion model that accurately describes the behavior of the primary wave harmonic of the pneumatic tubing. The model is expressed in state-variable form and is coupled with standard results from minimum-variance estimation theory to develop an algorithm to compensate for the effects of pneumatic distortion. Both postflight and real-time algorithms are developed and evaluated using simulated and flight data. Covariance selection and filter-tuning examples are presented. Results presented verify that, given appropriate covariance magnitudes, the algorithms accurately reconstruct surface pressure values from remotely sensed pressure measurements.

  6. Mechanical implications of pneumatic neck vertebrae in sauropod dinosaurs.

    PubMed

    Schwarz-Wings, Daniela; Meyer, Christian A; Frey, Eberhard; Manz-Steiner, Hans-Rudolf; Schumacher, Ralf

    2010-01-07

    The pre-sacral vertebrae of most sauropod dinosaurs were surrounded by interconnected, air-filled diverticula, penetrating into the bones and creating an intricate internal cavity system within the vertebrae. Computational finite-element models of two sauropod cervical vertebrae now demonstrate the mechanical reason for vertebral pneumaticity. The analyses show that the structure of the cervical vertebrae leads to an even distribution of all occurring stress fields along the vertebrae, concentrated mainly on their external surface and the vertebral laminae. The regions between vertebral laminae and the interior part of the vertebral body including thin bony struts and septa are mostly unloaded and pneumatic structures are positioned in these regions of minimal stress. The morphology of sauropod cervical vertebrae was influenced by strongly segmented axial neck muscles, which require only small attachment areas on each vertebra, and pneumatic epithelia that are able to resorb bone that is not mechanically loaded. The interaction of these soft tissues with the bony tissue of the vertebrae produced lightweight, air-filled vertebrae in which most stresses were borne by the external cortical bone. Cervical pneumaticity was therefore an important prerequisite for neck enlargement in sauropods. Thus, we expect that vertebral pneumaticity in other parts of the body to have a similar role in enabling gigantism.

  7. Mechanical implications of pneumatic neck vertebrae in sauropod dinosaurs

    PubMed Central

    Schwarz-Wings, Daniela; Meyer, Christian A.; Frey, Eberhard; Manz-Steiner, Hans-Rudolf; Schumacher, Ralf

    2010-01-01

    The pre-sacral vertebrae of most sauropod dinosaurs were surrounded by interconnected, air-filled diverticula, penetrating into the bones and creating an intricate internal cavity system within the vertebrae. Computational finite-element models of two sauropod cervical vertebrae now demonstrate the mechanical reason for vertebral pneumaticity. The analyses show that the structure of the cervical vertebrae leads to an even distribution of all occurring stress fields along the vertebrae, concentrated mainly on their external surface and the vertebral laminae. The regions between vertebral laminae and the interior part of the vertebral body including thin bony struts and septa are mostly unloaded and pneumatic structures are positioned in these regions of minimal stress. The morphology of sauropod cervical vertebrae was influenced by strongly segmented axial neck muscles, which require only small attachment areas on each vertebra, and pneumatic epithelia that are able to resorb bone that is not mechanically loaded. The interaction of these soft tissues with the bony tissue of the vertebrae produced lightweight, air-filled vertebrae in which most stresses were borne by the external cortical bone. Cervical pneumaticity was therefore an important prerequisite for neck enlargement in sauropods. Thus, we expect that vertebral pneumaticity in other parts of the body to have a similar role in enabling gigantism. PMID:19801376

  8. ALMA Pipeline Heuristics

    NASA Astrophysics Data System (ADS)

    Lightfoot, J.; Wyrowski, F.; Muders, D.; Boone, F.; Davis, L.; Shepherd, D.; Wilson, C.

    2006-07-01

    The ALMA (Atacama Large Millimeter Array) Pipeline Heuristics system is being developed to automatically reduce data taken with the standard observing modes. The goal is to make ALMA user-friendly to astronomers who are not experts in radio interferometry. The Pipeline Heuristics system must capture the expert knowledge required to provide data products that can be used without further processing. Observing modes to be processed by the system include single field interferometry, mosaics and single dish `on-the-fly' maps, and combinations of these modes. The data will be produced by the main ALMA array, the ALMA Compact Array (ACA) and single dish antennas. The Pipeline Heuristics system is being developed as a set of Python scripts. For interferometry these use as data processing engines the CASA/AIPS++ libraries and their bindings as CORBA objects within the ALMA Common Software (ACS). Initial development has used VLA and Plateau de Bure data sets to build and test a heuristic script capable of reducing single field data. In this paper we describe the reduction datapath and the algorithms used at each stage. Test results are presented. The path for future development is outlined.

  9. The inverse electroencephalography pipeline

    NASA Astrophysics Data System (ADS)

    Weinstein, David Michael

    The inverse electroencephalography (EEG) problem is defined as determining which regions of the brain are active based on remote measurements recorded with scalp EEG electrodes. An accurate solution to this problem would benefit both fundamental neuroscience research and clinical neuroscience applications. However, constructing accurate patient-specific inverse EEG solutions requires complex modeling, simulation, and visualization algorithms, and to date only a few systems have been developed that provide such capabilities. In this dissertation, a computational system for generating and investigating patient-specific inverse EEG solutions is introduced, and the requirements for each stage of this Inverse EEG Pipeline are defined and discussed. While the requirements of many of the stages are satisfied with existing algorithms, others have motivated research into novel modeling and simulation methods. The principal technical results of this work include novel surface-based volume modeling techniques, an efficient construction for the EEG lead field, and the Open Source release of the Inverse EEG Pipeline software for use by the bioelectric field research community. In this work, the Inverse EEG Pipeline is applied to three research problems in neurology: comparing focal and distributed source imaging algorithms; separating measurements into independent activation components for multifocal epilepsy; and localizing the cortical activity that produces the P300 effect in schizophrenia.

  10. 76 FR 11312 - Pipeline Safety: Meeting of the Technical Pipeline Safety Standards Committee and the Technical...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-03-01

    ... Safety Standards Committee and the Technical Hazardous Liquid Pipeline Safety Standards Committee AGENCY... Committee (TPSSC) and the Technical Hazardous Liquid Pipeline Safety Standards Committee (THLPSSC). The..., and safety policies for natural gas pipelines and for hazardous liquid pipelines. Both committees...

  11. 75 FR 4134 - Pipeline Safety: Leak Detection on Hazardous Liquid Pipelines

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-01-26

    ... Pipeline and Hazardous Materials Safety Administration Pipeline Safety: Leak Detection on Hazardous Liquid... this Advisory Bulletin to advise and remind hazardous liquid pipeline operators of the importance of... protecting people and the environment. The federal hazardous liquid pipeline safety regulations...

  12. 76 FR 29333 - Pipeline Safety: Meetings of the Technical Pipeline Safety Standards Committee and the Technical...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-05-20

    ... Safety Standards Committee and the Technical Hazardous Liquid Pipeline Safety Standards Committee AGENCY... Standards Committee (TPSSC) and the Technical Hazardous Liquid Pipeline Safety Standards Committee (THLPSSC... gas pipelines and for hazardous liquid pipelines. Both committees were established under the...

  13. 78 FR 41496 - Pipeline Safety: Meetings of the Gas and Liquid Pipeline Advisory Committees

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-07-10

    ... From the Federal Register Online via the Government Publishing Office DEPARTMENT OF TRANSPORTATION Pipeline and Hazardous Materials Safety Administration Pipeline Safety: Meetings of the Gas and Liquid Pipeline Advisory Committees AGENCY: Pipeline and Hazardous Materials Safety Administration (PHMSA),...

  14. 77 FR 45417 - Pipeline Safety: Inspection and Protection of Pipeline Facilities After Railway Accidents

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-07-31

    ... From the Federal Register Online via the Government Publishing Office DEPARTMENT OF TRANSPORTATION Pipeline and Hazardous Materials Safety Administration Pipeline Safety: Inspection and Protection of Pipeline Facilities After Railway Accidents AGENCY: Pipeline and Hazardous Materials Safety...

  15. Reactor for making uniform capsules

    NASA Technical Reports Server (NTRS)

    Wang, Taylor G. (Inventor); Anikumar, Amrutur V. (Inventor); Lacik, Igor (Inventor)

    1999-01-01

    The present invention provides a novel reactor for making capsules with uniform membrane. The reactor includes a source for providing a continuous flow of a first liquid through the reactor; a source for delivering a steady stream of drops of a second liquid to the entrance of the reactor; a main tube portion having at least one loop, and an exit opening, where the exit opening is at a height substantially equal to the entrance. In addition, a method for using the novel reactor is provided. This method involves providing a continuous stream of a first liquid; introducing uniformly-sized drops of the second liquid into the stream of the first liquid; allowing the drops to react in the stream for a pre-determined period of time; and collecting the capsules.

  16. 27 CFR 19.187 - Pipelines.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 1 2014-04-01 2014-04-01 false Pipelines. 19.187 Section... Package Scale and Pipeline Requirements § 19.187 Pipelines. All pipelines, including flexible hoses, that... TTB officer may approve pipelines that cannot be readily examined if they pose no jeopardy to...

  17. 27 CFR 19.187 - Pipelines.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 1 2013-04-01 2013-04-01 false Pipelines. 19.187 Section... Package Scale and Pipeline Requirements § 19.187 Pipelines. All pipelines, including flexible hoses, that... TTB officer may approve pipelines that cannot be readily examined if they pose no jeopardy to...

  18. 27 CFR 19.187 - Pipelines.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 1 2012-04-01 2012-04-01 false Pipelines. 19.187 Section... Package Scale and Pipeline Requirements § 19.187 Pipelines. All pipelines, including flexible hoses, that... TTB officer may approve pipelines that cannot be readily examined if they pose no jeopardy to...

  19. 27 CFR 19.187 - Pipelines.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 1 2011-04-01 2011-04-01 false Pipelines. 19.187 Section... Package Scale and Pipeline Requirements § 19.187 Pipelines. All pipelines, including flexible hoses, that... TTB officer may approve pipelines that cannot be readily examined if they pose no jeopardy to...

  20. Main Pipelines Corrosion Monitoring Device

    NASA Astrophysics Data System (ADS)

    Anatoliy, Bazhenov; Galina, Bondareva; Natalia, Grivennaya; Sergey, Malygin; Mikhail, Goryainov

    2017-01-01

    The aim of the article is to substantiate the technical solution for the problem of monitoring corrosion changes in oil and gas pipelines with use (using) of an electromagnetic NDT method. Pipeline wall thinning under operating conditions can lead to perforations and leakage of the product to be transported outside the pipeline. In most cases there is danger for human life and environment. Monitoring of corrosion changes in pipeline inner wall under operating conditions is complicated because pipelines are mainly made of structural steels with conductive and magnetic properties that complicate test signal passage through the entire thickness of the object under study. The technical solution of this problem lies in monitoring of the internal corrosion changes in pipes under operating conditions in order to increase safety of pipelines by automated prediction of achieving the threshold pre-crash values due to corrosion.

  1. Planned and proposed pipeline regulations

    SciTech Connect

    De Leon, C. )

    1992-04-01

    The Research and Special Programs Administration administers the Natural Gas Pipeline Safety Act of 1968 (NGPSA) and the Hazardous Liquid Pipeline Safety Act of 1979 (HLPSA). The RSPA issues and enforces design, construction, operation and maintenance regulations for natural gas pipelines and hazardous liquid pipelines. This paper discusses a number of proposed and pending safety regulations and legislative initiatives currently being considered by the RSPA and the US Congress. Some new regulations have been enacted. The next few years will see a great deal of regulatory activity regarding natural gas and hazardous liquid pipelines, much of it resulting from legislative requirements. The office of Pipeline Safety is currently conducting a study to streamline its operations. This study is analyzing the office's business, social and technical operations with the goal of improving overall efficiency, effectiveness, productivity and job satisfaction to meet the challenges of the future.

  2. A Novel MagPipe Pipeline transportation system using linear motor drives

    SciTech Connect

    Fang, J.R.; Montgomery, D.B.; Roderick, L.

    2009-11-15

    A novel capsule pipeline transportation system using linear motor drives, called Magplane MagPipe, is under development with the intention to replace trucks and railways for hauling materials from the mine to the rail head, power plant, or processing plant with reduced operating cost and energy consumption. The initial demonstration of a MagPipe line in Inner Mongolia will be a 500-m-long double-pipe coal transport system with the design transportation capacity of 3 Mega-Mg per year. The pipeline consists of 6-m-long plastic pipe modules with an I-beam suspension system inside the pipe to carry sets of five coupled capsules. The pipe will also contain noncontinuous motor winding modules spaced at 50-m intervals. A set of Halbach-arrayed permanent magnets on the bottom of the capsules interact with the linear motor windings to provide propulsion. The motor is driven by variable frequency drives outside the pipe to control the speed. This paper briefly describes the overall MagPipe pipeline transportation system, including the preliminary conclusions of the linear synchronous motor analysis.

  3. Capsule endoscopy: The road ahead

    PubMed Central

    Singeap, Ana-Maria; Stanciu, Carol; Trifan, Anca

    2016-01-01

    Since its introduction into clinical practice 15 years ago, capsule endoscopy (CE) has become the first-line investigation procedure in some small bowel pathologies, and more recently, dedicated esophageal and colon CE have expanded the fields of application to include the upper and lower gastrointestinal disorders. During this time, CE has become increasingly popular among gastroenterologists, with more than 2 million capsule examinations performed worldwide, and nearly 3000 PubMed-listed studies on its different aspects published. This huge interest in CE may be explained by its non-invasive nature, patient comfort, safety, and access to anatomical regions unattainable via conventional endoscopy. However, CE has several limitations which impede its wider clinical applications, including the lack of therapeutic capabilities, inability to obtain biopsies and control its locomotion. Several research groups are currently working to overcome these limitations, while novel devices able to control capsule movement, obtain high quality images, insufflate the gut lumen, perform chromoendoscopy, biopsy of suspect lesions, or even deliver targeted drugs directly to specific sites are under development. Overlooking current limitations, especially as some of them have already been successfully surmounted, and based on the tremendous progress in technology, it is expected that, by the end of next 15 years, CE able to perform both diagnostic and therapeutic procedures will remain the major form of digestive endoscopy. This review summarizes the literature that prognosticates about the future developments of CE. PMID:26755883

  4. A Pneumatic Actuated Microfluidic Beads-Trapping Device

    SciTech Connect

    Shao, Guocheng; Cai, Ziliang; Wang, Jun; Wang, Wanjun; Lin, Yuehe

    2011-08-20

    The development of a polydimethylsiloxane (PDMS) microfluidic microbeads trapping device is reported in this paper. Besides fluid channels, the proposed device includes a pneumatic control chamber and a beads-trapping chamber with a filter array structure. The pneumatic flow control chamber and the beads-trapping chamber are vertically stacked and separated by a thin membrane. By adjusting the pressure in the pneumatic control chamber, the membrane can either be pushed against the filter array to set the device in trapping mode or be released to set the device in releasing mode. In this paper, a computational fluid dynamics simulation was conducted to optimize the geometry design of the filter array structure; the device fabrication was also carried out. The prototype device was tested and the preliminary experimental results showed that it can be used as a beads-trapping unit for various biochemistry and analytical chemistry applications, especially for flow injection analysis systems.

  5. An ankle-foot orthosis powered by artificial pneumatic muscles.

    PubMed

    Ferris, Daniel P; Czerniecki, Joseph M; Hannaford, Blake

    2005-05-01

    We developed a pneumatically powered orthosis for the human ankle joint. The orthosis consisted of a carbon fiber shell, hinge joint, and two artificial pneumatic muscles. One artificial pneumatic muscle provided plantar flexion torque and the second one provided dorsiflexion torque. Computer software adjusted air pressure in each artificial muscle independently so that artificial muscle force was proportional to rectified low-pass-filtered electromyography (EMG) amplitude (i.e., proportional myoelectric control). Tibialis anterior EMG activated the artificial dorsiflexor and soleus EMG activated the artificial plantar flexor. We collected joint kinematic and artificial muscle force data as one healthy participant walked on a treadmill with the orthosis. Peak plantar flexor torque provided by the orthosis was 70 Nm, and peak dorsiflexor torque provided by the orthosis was 38 Nm. The orthosis could be useful for basic science studies on human locomotion or possibly for gait rehabilitation after neurological injury.

  6. An Ankle-Foot Orthosis Powered by Artificial Pneumatic Muscles

    PubMed Central

    Ferris, Daniel P.; Czerniecki, Joseph M.; Hannaford, Blake

    2005-01-01

    We developed a pneumatically powered orthosis for the human ankle joint. The orthosis consisted of a carbon fiber shell, hinge joint, and two artificial pneumatic muscles. One artificial pneumatic muscle provided plantar flexion torque and the second one provided dorsiflexion torque. Computer software adjusted air pressure in each artificial muscle independently so that artificial muscle force was proportional to rectified low-pass-filtered electromyography (EMG) amplitude (i.e., proportional myoelectric control). Tibialis anterior EMG activated the artificial dorsiflexor and soleus EMG activated the artificial plantar flexor. We collected joint kinematic and artificial muscle force data as one healthy participant walked on a treadmill with the orthosis. Peak plantar flexor torque provided by the orthosis was 70 Nm, and peak dorsiflexor torque provided by the orthosis was 38 Nm. The orthosis could be useful for basic science studies on human locomotion or possibly for gait rehabilitation after neurological injury. PMID:16082019

  7. 46 CFR 54.10-15 - Pneumatic test (modifies UG-100).

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... first opportunity following the pneumatic test. The tank supports and saddles, connecting piping, and... 46 Shipping 2 2010-10-01 2010-10-01 false Pneumatic test (modifies UG-100). 54.10-15 Section 54.10... VESSELS Inspection, Reports, and Stamping § 54.10-15 Pneumatic test (modifies UG-100). (a)...

  8. 46 CFR 128.240 - Hydraulic or pneumatic power and control-materials and pressure design.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 4 2012-10-01 2012-10-01 false Hydraulic or pneumatic power and control-materials and... Hydraulic or pneumatic power and control—materials and pressure design. (a) Each standard piping component (such as pipe runs, fittings, flanges, and standard valves) for hydraulic or pneumatic power and...

  9. 46 CFR 128.240 - Hydraulic or pneumatic power and control-materials and pressure design.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Hydraulic or pneumatic power and control-materials and... Hydraulic or pneumatic power and control—materials and pressure design. (a) Each standard piping component (such as pipe runs, fittings, flanges, and standard valves) for hydraulic or pneumatic power and...

  10. 46 CFR 128.240 - Hydraulic or pneumatic power and control-materials and pressure design.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 4 2014-10-01 2014-10-01 false Hydraulic or pneumatic power and control-materials and... Hydraulic or pneumatic power and control—materials and pressure design. (a) Each standard piping component (such as pipe runs, fittings, flanges, and standard valves) for hydraulic or pneumatic power and...

  11. 46 CFR 128.240 - Hydraulic or pneumatic power and control-materials and pressure design.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 4 2013-10-01 2013-10-01 false Hydraulic or pneumatic power and control-materials and... Hydraulic or pneumatic power and control—materials and pressure design. (a) Each standard piping component (such as pipe runs, fittings, flanges, and standard valves) for hydraulic or pneumatic power and...

  12. 14 CFR 23.1416 - Pneumatic de-icer boot system.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 14 Aeronautics and Space 1 2014-01-01 2014-01-01 false Pneumatic de-icer boot system. 23.1416... Safety Equipment § 23.1416 Pneumatic de-icer boot system. If certification with ice protection provisions is desired and a pneumatic de-icer boot system is installed— (a) The system must meet...

  13. 14 CFR 23.1416 - Pneumatic de-icer boot system.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Pneumatic de-icer boot system. 23.1416... Safety Equipment § 23.1416 Pneumatic de-icer boot system. If certification with ice protection provisions is desired and a pneumatic de-icer boot system is installed— (a) The system must meet...

  14. 14 CFR 23.1416 - Pneumatic de-icer boot system.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 14 Aeronautics and Space 1 2012-01-01 2012-01-01 false Pneumatic de-icer boot system. 23.1416... Safety Equipment § 23.1416 Pneumatic de-icer boot system. If certification with ice protection provisions is desired and a pneumatic de-icer boot system is installed— (a) The system must meet...

  15. 14 CFR 23.1416 - Pneumatic de-icer boot system.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 14 Aeronautics and Space 1 2013-01-01 2013-01-01 false Pneumatic de-icer boot system. 23.1416... Safety Equipment § 23.1416 Pneumatic de-icer boot system. If certification with ice protection provisions is desired and a pneumatic de-icer boot system is installed— (a) The system must meet...

  16. 78 FR 3843 - Federal Motor Vehicle Safety Standards; New Pneumatic and Certain Specialty Tires

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-01-17

    ... Pneumatic Tyres For Passenger-Use Motor Vehicles, Annex, 1-2-5. We believed that existing 60-psi T-type... Standards; New Pneumatic and Certain Specialty Tires AGENCY: National Highway Traffic Safety Administration... Motor Vehicle Safety Standard (FMVSS) No. 109, New pneumatic and certain specialty tires, to change...

  17. Seismic assessment for offshore pipelines

    SciTech Connect

    Bruschi, R.; Gudmestad, O.T.; Blaker, F.; Nadim, F.

    1995-12-31

    An international consensus on seismic design criteria for onshore pipelines has been established during the last thirty years. The need to assess seismic design for offshore pipelines has not been similarly recognized. In this paper, the geotechnical hazard for a pipeline routed across steep slopes and irregular terrains affected by earthquakes, is discussed. The integrity of both natural and artificial load bearing supports is assessed.d The response of the pipeline to direct excitation from soil or through discontinuous, sparsely distributed natural or artificial supports, is commented.

  18. Evaluation of a pneumatic Martian soil sampler concept

    NASA Technical Reports Server (NTRS)

    Schaefer, John L.; Neathery, James K.; Stencel, John M.

    1994-01-01

    The pneumatic soil sampler concept was successfully demonstrated by penetrating a Martian simulant soil to a depth of 2 meters. Working gas pressure, composition, and pulsing were evaluated with the objective of minimizing gas usage. Also, the probe penetration force was investigated with the objective of minimizing probe weight. Gas and probe penetration force, while not yet optimized, are within the range which make the soil sampler concept feasible. While the tests described in this report did not answer all the questions and address all the variables associated with pneumatic soil sampling, valuable data experience and knowledge were gained which can be used to further develop the concept.

  19. Overall life cycle comprehensive assessment of pneumatic and electric actuator

    NASA Astrophysics Data System (ADS)

    Zhang, Yeming; Cai, Maolin

    2014-05-01

    Pneumatic actuators and electric actuators have almost been applied to all manufacturing industries. The two kinds of actuators can replace each other in most fields, such as the point to point transmission occasion and some rotating occasions. However, there are very few research results about the advantages and disadvantages of two kinds of actuators under the same working conditions so far. In this paper, a novel comprehensive assessment method, named as overall life cycle comprehensive assessment (OLCCA), is proposed for comparison and assessment of pneumatic and electric actuators. OLCCA contains mechanical properties evaluation (MPE), life cycle cost analysis based on users (LCCABOU) and life cycle environmental impact analysis (LCEIA) algorithm in order to solve three difficult problems: mechanical properties assessment, cost analysis and environmental impact assessment about actuators. The mechanical properties evaluation of actuators is a multi-objective optimization problem. The fuzzy data quantification and information entropy methods are combined to establish MPE algorithm of actuators. Two kinds of pneumatic actuators and electric actuators with similar bearing capacity and similar work stroke were taken for example to verify the correctness of MPE algorithm. The case study of MPE algorithm for actuators verified its correctness. LCCABOU for actuators is also set up. Considering cost complex structure of pneumatic actuators, public device cost even method (PDCEM) is firstly presented to solve cost division of public devices such as compressors, aftercooler, receivers, etc. LCCABOU method is also effective and verified by the three groups of pneumatic actuators and electric actuators. Finally, LCEIA model of actuators is established for the environmental impact assessment of actuators. LCEIA data collection method and model establishment procedure for actuators are also put forward. With Simapro 7, LCEIA comparison results of six actuators can be

  20. Compensating for pneumatic distortion in pressure sensing devices

    NASA Technical Reports Server (NTRS)

    Whitmore, Stephen A.; Leondes, Cornelius T.

    1990-01-01

    A general numerical technique for obtaining unsteady pressure measurements using conventional pressure sensing technology has been developed. A pneumatic distortion model, based on the Navier-Stokes equations of momentum and continuity, was reduced to a low-order, state-variable model retaining most of the dynamic characteristics of the full model. The reduced-order model is coupled with results from minimum variance estimation theory to develop an algorithm to compensate the effects of pneumatic distortion. Both postflight and real-time algorithms were developed and evaluated using simulated and flight data.

  1. A pneumatic vibrotactile stimulation device for fMRI.

    PubMed

    Briggs, Richard W; Dy-Liacco, Iona; Malcolm, Matthew P; Lee, Hyunsook; Peck, Kyung K; Gopinath, Kaundinya S; Himes, Nathan C; Soltysik, David A; Browne, Paul; Tran-Son-Tay, Roger

    2004-03-01

    Mapping the functional response of the somatosensory cortex is useful both for characterizing normal brain activity and for determining the functional integrity of damaged cortex compromised by stroke or other neurological insults. A variety of stimulators have been used to produce somatosensory cortex activation in functional brain imaging, including brushes and swabs operated manually, pneumatically and mechanically powered mechanical vibrators, air puffs, and vibrating ceramic piezoelectric wafers and benders. A closed-system, pneumatically driven rubber diaphragm is reported that overcomes many of the limitations of existing vibrotactile devices and produces robust sensory cortex activation in an fMRI experiment.

  2. INTERNAL REPAIR OF PIPELINES

    SciTech Connect

    Bill Bruce; Nancy Porter; George Ritter; Matt Boring; Mark Lozev; Ian Harris; Bill Mohr; Dennis Harwig; Robin Gordon; Chris Neary; Mike Sullivan

    2005-07-20

    The two broad categories of fiber-reinforced composite liner repair and deposited weld metal repair technologies were reviewed and evaluated for potential application for internal repair of gas transmission pipelines. Both are used to some extent for other applications and could be further developed for internal, local, structural repair of gas transmission pipelines. Principal conclusions from a survey of natural gas transmission industry pipeline operators can be summarized in terms of the following performance requirements for internal repair: (1) Use of internal repair is most attractive for river crossings, under other bodies of water, in difficult soil conditions, under highways, under congested intersections, and under railway crossings. (2) Internal pipe repair offers a strong potential advantage to the high cost of horizontal direct drilling when a new bore must be created to solve a leak or other problem. (3) Typical travel distances can be divided into three distinct groups: up to 305 m (1,000 ft.); between 305 m and 610 m (1,000 ft. and 2,000 ft.); and beyond 914 m (3,000 ft.). All three groups require pig-based systems. A despooled umbilical system would suffice for the first two groups which represents 81% of survey respondents. The third group would require an onboard self-contained power unit for propulsion and welding/liner repair energy needs. (4) The most common size range for 80% to 90% of operators surveyed is 508 mm (20 in.) to 762 mm (30 in.), with 95% using 558.8 mm (22 in.) pipe. Evaluation trials were conducted on pipe sections with simulated corrosion damage repaired with glass fiber-reinforced composite liners, carbon fiber-reinforced composite liners, and weld deposition. Additional un-repaired pipe sections were evaluated in the virgin condition and with simulated damage. Hydrostatic failure pressures for pipe sections repaired with glass fiber-reinforced composite liner were only marginally greater than that of pipe sections without

  3. HPMC capsules: current status and future prospects.

    PubMed

    Al-Tabakha, Moawia M

    2010-01-01

    Hydroxypropyl methylcellulose (HPMC) is employed for a wide variety of pharmaceutical and food preparations. Its applications as viscolizing agent (thickening agent), coating polymer, bioadhesive, in solid dispersion to enhance solubility, binder in the process of granulation and in modified release formulations have been well documented. One other notable use is in the production of capsule shells, replacing the animal derived gelatin in conventional two-piece capsules. The aim of this review is to systemically survey published literature on the HPMC use in capsule shells and resolve questions regarding their suitability as a replacement for hard gelatin capsules. Future refinements in the production and filling of HPMC capsule shells and improvement in their in vivo/in vitro dissolution would ensure their superiority over hard gelatin capsules.

  4. 77 FR 19799 - Pipeline Safety: Pipeline Damage Prevention Programs

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-04-02

    ...This Notice of Proposed Rulemaking (NPRM) seeks to revise the Pipeline Safety Regulations to: Establish criteria and procedures for determining the adequacy of state pipeline excavation damage prevention law enforcement programs; establish an administrative process for making adequacy determinations; establish the Federal requirements PHMSA will enforce in states with inadequate excavation......

  5. 76 FR 53086 - Pipeline Safety: Safety of Gas Transmission Pipelines

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-08-25

    ... stress corrosion cracking (SCC) in hazardous liquid pipeline systems. On December 4, 2009, PHMSA issued... surveys; close interval surveys for cathodic protection (CP) verification; coating surveys and recoating... valves; whether requirements for corrosion control of steel pipelines should be strengthened; and...

  6. The bacterial proteogenomic pipeline

    PubMed Central

    2014-01-01

    Background Proteogenomics combines the cutting-edge methods from genomics and proteomics. While it has become cheap to sequence whole genomes, the correct annotation of protein coding regions in the genome is still tedious and error prone. Mass spectrometry on the other hand relies on good characterizations of proteins derived from the genome, but can also be used to help improving the annotation of genomes or find species specific peptides. Additionally, proteomics is widely used to find evidence for differential expression of proteins under different conditions, e.g. growth conditions for bacteria. The concept of proteogenomics is not altogether new, in-house scripts are used by different labs and some special tools for eukaryotic and human analyses are available. Results The Bacterial Proteogenomic Pipeline, which is completely written in Java, alleviates the conducting of proteogenomic analyses of bacteria. From a given genome sequence, a naïve six frame translation is performed and, if desired, a decoy database generated. This database is used to identify MS/MS spectra by common peptide identification algorithms. After combination of the search results and optional flagging for different experimental conditions, the results can be browsed and further inspected. In particular, for each peptide the number of identifications for each condition and the positions in the corresponding protein sequences are shown. Intermediate and final results can be exported into GFF3 format for visualization in common genome browsers. Conclusions To facilitate proteogenomics analyses the Bacterial Proteogenomic Pipeline is a set of comprehensive tools running on common desktop computers, written in Java and thus platform independent. The pipeline allows integrating peptide identifications from various algorithms and emphasizes the visualization of spectral counts from different experimental conditions. PMID:25521444

  7. Biotech pipeline: Bottleneck ahead

    SciTech Connect

    Gibbons, A.

    1991-10-18

    A vast array of new genetically engineered drugs are heading for market - but an FDA backlog is holding them up. Patients may have to wait far longer than the biotech enthusiasts suggest before they reap the benefits of those new drugs. There is little hope the FDA will get the money it needs to do the job. The agency's pipeline is clogged with at least 58 monoclonal antibody-based drugs at all stages of testing to diagnose and treat a wide range of diseases, including a half-dozen cancers, diabetes, and sepsis.

  8. Perform Ultrasonic Testing on Cs Capsule Overpacks

    SciTech Connect

    DAVIS, S.J.

    2000-04-06

    This procedure provides a safe, uniform method for the performance of the ultrasonic weld inspection of the Cesium capsule overpacks. The inspection system will detect cracks, lack of fusion, and lack of penetration. This computer controlled automated system will perform the examination once the capsule overpack has been placed in the pool cell. Examination of the capsule overpacks will be in accordance with drawing H-283014, REV. 0 ,and a certified NDE examiner will perform the test procedure, provide analysis, and test documentation.

  9. Postoperative radiation and implant capsule contraction

    SciTech Connect

    Caffee, H.H.; Mendenhall, N.P.; Mendenhall, W.M.; Bova, F.J.

    1988-01-01

    Occasionally radiation is required as adjunctive therapy following mastectomy for breast cancer. The effects of radiation on a developing implant capsule are unknown, but they are very important in relation to the increased use of immediate reconstruction. Experiments were performed on rabbits to study the effects of postoperative radiation therapy on capsule contraction and thickness. The results of these experiments suggest that radiation has no effect on implant capsules.

  10. Design considerations for single-stage and two-stage pneumatic pellet injectors

    SciTech Connect

    Gouge, M.J.; Combs, S.K.; Fisher, P.W.; Milora, S.L.

    1988-09-01

    Performance of single-stage pneumatic pellet injectors is compared with several models for one-dimensional, compressible fluid flow. Agreement is quite good for models that reflect actual breech chamber geometry and incorporate nonideal effects such as gas friction. Several methods of improving the performance of single-stage pneumatic pellet injectors in the near term are outlined. The design and performance of two-stage pneumatic pellet injectors are discussed, and initial data from the two-stage pneumatic pellet injector test facility at Oak Ridge National Laboratory are presented. Finally, a concept for a repeating two-stage pneumatic pellet injector is described. 27 refs., 8 figs., 3 tabs.

  11. Duodenum identification mechanism for capsule endoscopy.

    PubMed

    Woo, Sang Hyo; Mohy-Ud-Din, Zia; Cho, Jin Ho

    2011-04-01

    The aim of this study is to implement a duodenum identification mechanism for capsule endoscopes because commercially available capsule endoscopes sometimes present a false negative diagnosis of the duodenum. One reason for the false negative diagnosis is that the duodenum is the fastest moving part within the gastrointestinal tract and the current frame rate of the capsule is not fast enough. When the capsule can automatically identify that it is in the duodenum, the frame rate of the capsule can be temporarily increased to reduce the possibility of a false negative diagnosis. This study proposes a mechanism to identify the duodenum using capacitive proximity sensors that can distinguish the surrounding tissue and transmit data using RF communication. The implemented capsule (D11 mm × L22 mm) was smaller than the commercially available capsule endoscopes, and power consumption was as low as 0.642 mW. Preexperiments were conducted to select an appropriate electrode width in order to increase the signal-to-noise ratio (SNR), and in vitro experiments were conducted to verify whether the implemented capsule could identify the duodenum within 3 s. The experiment showed that the identification rate of duodenum was 93% when the velocity of the capsule was less than 1 cm/s.

  12. Velocity measurement of pneumatically conveyed solid particles using an electrostatic sensor

    NASA Astrophysics Data System (ADS)

    Xu, C.; Zhou, B.; Yang, D.; Tang, G.; Wang, S.

    2008-02-01

    The paper proposes a method to measure the mean velocity of solid particles based on the spatial filtering effect of the electrostatic sensor. To determine the relationship between the spatial frequency characteristics of the sensor and solid particle velocity, a general formula is derived by analyzing quantitatively the spatial filtering characteristics of the electrostatic sensor along with the accepted assumptions. The effects of the geometric parameters of the sensor, particle velocity distribution, particle concentration distribution over the cross-section of a pneumatic pipeline, particle size, particle material type and frequency resolution on particle velocity measurement accuracy are also discussed in detail. Experiments are performed on a bench-scale gravity-fed particle flow experimental rig to test the performance of the velocity measurement system. The off-line experimental results show that the system repeatability is within ±5% over the velocity range of 2-6 m s-1 for concentrations of solid particles in the range of 0.5-6.0%.

  13. Academic Pipeline and Futures Lab

    DTIC Science & Technology

    2016-02-01

    level for summer time programs. The Academic Pipeline will also work with other programs at AFRL and with other universities and organizations to...AFRL-RY-WP-TR-2015-0186 ACADEMIC PIPELINE AND FUTURES LAB Brian D. Rigling Wright State University FEBRUARY 2016...PUBLICATION IN ACCORDANCE WITH ASSIGNED DISTRIBUTION STATEMENT. // Signature// // Signature// KELLY MILLER, Program Manager CHRISTINA

  14. Pipeline Processing for VISTA

    NASA Astrophysics Data System (ADS)

    Lewis, J. R.; Irwin, M.; Bunclark, P.

    2010-12-01

    The VISTA telescope is a 4 metre instrument which has recently been commissioned at Paranal, Chile. Equipped with an infrared camera, 16 2Kx2K Raytheon detectors and a 1.7 square degree field of view, VISTA represents a huge leap in infrared survey capability in the southern hemisphere. Pipeline processing of IR data is far more technically challenging than for optical data. IR detectors are inherently more unstable, while the sky emission is over 100 times brighter than most objects of interest, and varies in a complex spatial and temporal manner. To compensate for this, exposure times are kept short, leading to high nightly data rates. VISTA is expected to generate an average of 250 GB of data per night over the next 5-10 years, which far exceeds the current total data rate of all 8m-class telescopes. In this presentation we discuss the pipelines that have been developed to deal with IR imaging data from VISTA and discuss the primary issues involved in an end-to-end system capable of: robustly removing instrument and night sky signatures; monitoring data quality and system integrity; providing astrometric and photometric calibration; and generating photon noise-limited images and science-ready astronomical catalogues.

  15. Alaska Pipeline Insulation

    NASA Technical Reports Server (NTRS)

    1979-01-01

    Crude oil moving through the 800-mile Trans-Alaska Pipeline must be kept at a relatively high temperature, about 180 degrees Fahrenheit, to maintain the fluidity of the oil. In Arctic weather, that demands highly effective insulation. General Electric Co.'s Space Division, Valley Forge, Pennsylvania, provided it with a spinoff product called Therm-O-Trol. Shown being installed on the pipeline, Therm-O-Trol is a metal-bonded polyurethane foam especially formulated for Arctic insulation. A second GE spinoff product, Therm-O-Case, solved a related problem involved in bringing hot crude oil from 2,000-foot-deep wells to the surface without transferring oil heat to the surrounding permafrost soil; heat transfer could melt the frozen terrain and cause dislocations that might destroy expensive well casings. Therm-O-Case is a double-walled oil well casing with multi-layered insulation which provides an effective barrier to heat transfer. Therm-O-Trol and Therm-O-Case are members of a family of insulating products which stemmed from technology developed by GE Space Division in heat transferlthermal control work on Gemini, Apollo and other NASA programs.

  16. Low-energy pneumatic control of forebody vortices

    NASA Technical Reports Server (NTRS)

    Roos, Frederick W.

    1994-01-01

    This research will be exploring the prospect of employing bluntness, known to suppress the tendency toward asymmetry on slender forebodies, jointly with pneumatic manipulation as a system of forebody asymmetry control. The influences of jet location and direction, blowing rate, relative noise bluntness, angle of attack, and state of flow separation feeding the vortices (laminar vs. turbulent) will be evaluated.

  17. Control and monitoring system for clinically employed pneumatic blood pumps.

    PubMed

    Normann, N A; Henrichsen, D W; Cooper, T G; King, R E; Noon, G P; DeBakey, M E

    1977-01-01

    Instantaneous position of the flexing member in pneumatic blood pumps is monitored on-line by measuring the electrical capacitance across the gas space within the pump. Monitor output is utilized in closed-loop pump control and for automatic pump shutdown in response to operational abnormalities. Thus, safety and efficacy are enhanced through operational optimization, automatic safety features, and facilitated evaluation.

  18. Pneumatic Power Drive Wheel and related assembly for Turntable, with ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Pneumatic Power Drive Wheel and related assembly for Turntable, with scale. Not in use August 1994. Turntable rotated with engine and tender on balance by two persons, one on either side at ground level - East Broad Top Railroad & Coal Company, Roundhouse, State Route 994, West of U.S. Route 522, Rockhill Furnace, Huntingdon County, PA

  19. 116. PNEUMATIC SUPPLY PANEL IN CENTER OF VEHICLE MECHANICAL SYSTEMS ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    116. PNEUMATIC SUPPLY PANEL IN CENTER OF VEHICLE MECHANICAL SYSTEMS ROOM (111) OF LSB (BLDG. 770), FACING NORTH. CONTROLS FOR FLOW AND PRESSURE REGULATION OF NITROGEN ON RIGHT SIDE OF PANEL; CONTROLS FOR HELIUM ON LEFT SIDE OF PANEL (AT LEFT EDGE OF PHOTO). - Vandenberg Air Force Base, Space Launch Complex 3, Launch Pad 3 West, Napa & Alden Roads, Lompoc, Santa Barbara County, CA

  20. 117. PNEUMATIC SUPPLY PANEL IN CENTER OF VEHICLE MECHANICAL SYSTEMS ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    117. PNEUMATIC SUPPLY PANEL IN CENTER OF VEHICLE MECHANICAL SYSTEMS ROOM (111), LSB (BLDG. 770), FACING NORTH. CONTROLS FOR FLOW AND PRESSURE REGULATION OF HELIUM ON LEFT SIDE OF PANEL; CONTROLS FOR NITROGEN ON RIGHT SIDE OF PANEL (AT RIGHT EDGE OF PHOTO). - Vandenberg Air Force Base, Space Launch Complex 3, Launch Pad 3 West, Napa & Alden Roads, Lompoc, Santa Barbara County, CA

  1. A Synchronous Mutual Position Control for Vertical Pneumatic Servo System

    NASA Astrophysics Data System (ADS)

    Shibata, Satoru; Yamamoto, Tomonori; Jindai, Mitsuru

    Synchronous control of mutual position for two vertical-type pneumatic servo systems is discussed for practical use in this study. In the proposed control system, a fuzzy controller is used in each pneumatic servo system so that the output of each plant can follow the reference input. A PD controller is introduced to realize the synchronization of both pneumatic servo systems, in which the outputs from this controller are the inputs for revision to both plants. A fuzzy virtual reference generator that can adjust the reference input to both fuzzy controllers adaptively by fuzzy rules is constructed to improve the transient performances of both axes. In addition, the adjustment controller produces a representative value of both cylinder outputs, which is used to synthesize the inputs to the fuzzy virtual reference generator, in order to reach a compromise between the follow-up ability to the reference input in each axis and synchronization of both axes. The applicability of the proposed method is confirmed by experiments using two existent vertical-type pneumatic servo systems.

  2. Characteristics of pneumatically-emplaced dry flue gas desulfurization materials

    SciTech Connect

    Carter, S.D.; Rathbone, R.F.; Graham, U.M.; Robl, T.L.

    1996-12-31

    The University of Kentucky in collaboration with the Department of Energy, Addington, Inc. and Costain Coal is currently developing a commercial concept for the haul back of dry flue gas desulfurization materials (FGDM) into highwall mine adits. The University`s Center for Applied Energy Research (CAER) is investigating emplacement systems for a mine demonstration which is planned for the third quarter of 1996. A laboratory-scale transport system has been built at the CAER to evaluate the potential of pneumatic transport for FGDM emplacement. The system is modeled after shotcreting systems in which water is mixed with cement (FGDM) in a nozzle at the end of the pneumatic pipe. Solids travel approximately 70 ft in the lab-scale system at a rate of up to 6 lb FGDM/minute prior to impingement onto a sample collector. Prehydrated FGDM from a circulating fluidized bed combustor has been successfully emplaced onto vertically positioned sample surfaces without excessive dust liberation. The test program is focussed on determining the pneumatic conditions necessary to maximize the strength of the emplaced FGDM under anticipated mine curing conditions while minimizing dust formation. The mineralogy and strength of a pneumatically created sample are described following curing for 60 days.

  3. 21 CFR 890.3610 - Rigid pneumatic structure orthosis.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Rigid pneumatic structure orthosis. 890.3610 Section 890.3610 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... for medical purposes to provide whole body support by means of a pressurized suit to help...

  4. 21 CFR 890.3610 - Rigid pneumatic structure orthosis.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Rigid pneumatic structure orthosis. 890.3610 Section 890.3610 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... for medical purposes to provide whole body support by means of a pressurized suit to help...

  5. 21 CFR 890.3610 - Rigid pneumatic structure orthosis.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Rigid pneumatic structure orthosis. 890.3610 Section 890.3610 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... for medical purposes to provide whole body support by means of a pressurized suit to help...

  6. 21 CFR 890.3610 - Rigid pneumatic structure orthosis.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Rigid pneumatic structure orthosis. 890.3610 Section 890.3610 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES PHYSICAL MEDICINE DEVICES Physical Medicine Prosthetic Devices § 890.3610...

  7. 21 CFR 890.3610 - Rigid pneumatic structure orthosis.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Rigid pneumatic structure orthosis. 890.3610 Section 890.3610 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES PHYSICAL MEDICINE DEVICES Physical Medicine Prosthetic Devices § 890.3610...

  8. Pneumatic Conveying of Seed Cotton: Minimum Velocity and Pressure Drop

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Electricity is a major cost for cotton gins, representing approximately 20% of variable costs. Fans used for pneumatic conveying consume the majority of electricity at cotton gins. Development of control systems to reduce the air velocity used for conveying seed cotton could significantly decrease e...

  9. Pneumatic Conveying of Seed Cotton: Minimum Velocity and Pressure Drop

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Electricity is major cost for cotton gins, representing approximately 20% of the industry’s variable costs. Fans used for pneumatic conveying consume the majority of electricity at cotton gins. Development of control systems to reduce the air velocity used for conveying seed cotton could significant...

  10. Pneumatic vacuum tube message center, basement room 23, looking southeast ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Pneumatic vacuum tube message center, basement room 23, looking southeast toward doorway and corridor. Note soundproof walls, pedestal flooring, and cable tray suspended from the ceiling - March Air Force Base, Strategic Air Command, Combat Operations Center, 5220 Riverside Drive, Moreno Valley, Riverside County, CA

  11. Adaptive backstepping slide mode control of pneumatic position servo system

    NASA Astrophysics Data System (ADS)

    Ren, Haipeng; Fan, Juntao

    2016-09-01

    With the price decreasing of the pneumatic proportional valve and the high performance micro controller, the simple structure and high tracking performance pneumatic servo system demonstrates more application potential in many fields. However, most existing control methods with high tracking performance need to know the model information and to use pressure sensor. This limits the application of the pneumatic servo system. An adaptive backstepping slide mode control method is proposed for pneumatic position servo system. The proposed method designs adaptive slide mode controller using backstepping design technique. The controller parameter adaptive law is derived from Lyapunov analysis to guarantee the stability of the system. A theorem is testified to show that the state of closed-loop system is uniformly bounded, and the closed-loop system is stable. The advantages of the proposed method include that system dynamic model parameters are not required for the controller design, uncertain parameters bounds are not need, and the bulk and expensive pressure sensor is not needed as well. Experimental results show that the designed controller can achieve better tracking performance, as compared with some existing methods.

  12. The Pneumatic Common: Learning in, with and from the Air

    ERIC Educational Resources Information Center

    Ford, Derek R.

    2015-01-01

    Air is an immersive substance that envelopes us and binds us together, yet it has dominantly been taken for granted and left out of educational and other theorizations. This article develops a conceptualization of the "pneumatic common" in order to address this gap. The specific intervention staged is within recent educational literature…

  13. Design Improvements and Analysis of Innovative High-Level Waste Pipeline Unplugging Technologies - 12171

    SciTech Connect

    Pribanic, Tomas; Awwad, Amer; Crespo, Jairo; McDaniel, Dwayne; Varona, Jose; Gokaltun, Seckin; Roelant, David

    2012-07-01

    Transferring high-level waste (HLW) between storage tanks or to treatment facilities is a common practice performed at the Department of Energy (DoE) sites. Changes in the chemical and/or physical properties of the HLW slurry during the transfer process may lead to the formation of blockages inside the pipelines resulting in schedule delays and increased costs. To improve DoE's capabilities in the event of a pipeline plugging incident, FIU has continued to develop two novel unplugging technologies: an asynchronous pulsing system and a peristaltic crawler. The asynchronous pulsing system uses a hydraulic pulse generator to create pressure disturbances at two opposite inlet locations of the pipeline to dislodge blockages by attacking the plug from both sides remotely. The peristaltic crawler is a pneumatic/hydraulic operated crawler that propels itself by a sequence of pressurization/depressurization of cavities (inner tubes). The crawler includes a frontal attachment that has a hydraulically powered unplugging tool. In this paper, details of the asynchronous pulsing system's ability to unplug a pipeline on a small-scale test-bed and results from the experimental testing of the second generation peristaltic crawler are provided. The paper concludes with future improvements for the third generation crawler and a recommended path forward for the asynchronous pulsing testing. (authors)

  14. Dimensions, septation, and pattern of pneumatization of the sphenoidal sinus.

    PubMed

    Idowu, O E; Balogun, B O; Okoli, C A

    2009-11-01

    The endoscopic endonasal transsphenoidal approach (EEA) to treat sellar, parasellar, and suprasellar tumours continues to gain increased significance. Due to the close proximity of the sphenoid sinus to the carotid artery and the optic canal, it is very important for surgeons to know the anatomical features and variations of the sphenoid sinus as relevant to EEA. A prospective study of the sphenoid sinus morphology was carried out on the cranial tomographic (CT) scan images of 60 Nigerian adult patients. The CTs were reviewed regarding the different anatomical variations of the sphenoid sinus: dimensions, septation, and pattern of pneumatisation. There were 37 males and 23 females. The patients' ages ranged from 18 years to 85 years, with a mean of 47.2 years. There was a main single intersphenoid septum in most patients (95%). The insertion of the septum was usually to the right posteriorly (38%) and in the midline anterior (65%). Although there is usually a main septum, the septa present were multiple in 29 of the sinuses studied. There was no gender difference with respect to the attachment of the main sphenoid sinus septum. The sphenoid anterior, posterior, and transverse dimensions were not significantly dependent on age, but they were longer in males than in females. Sellar pneumatization was present in the majority of the patients (83%), with 4 patients having postsellar pneumatization (6.7%) and 3 patients having presellar pneumatization (5%). There were no cases with conchal pneumatization or lateral pneumatization of the greater wing of the sphenoid. The present study provides anatomical information about the sphenoid sinus dimensions morphology that is essential for avoiding complications in performing an endoscopic sphenoidotomy.

  15. The disintegration behaviour of capsules in fed subjects: a comparison of hypromellose (carrageenan) capsules and standard gelatin capsules.

    PubMed

    Jones, B E; Basit, A W; Tuleu, C

    2012-03-15

    Two-piece hard shell capsules made from hypromellose (or hydroxypropyl methylcellulose, HPMC) containing carrageenan as a gelling agent have been proposed as an alternative to conventional gelatin capsules for oral drug delivery. We have previously compared the disintegration of hypromellose(carrageenan) (Quali-V(®)) and gelatin capsules (Qualicaps) in fasted human subjects using the technique of gamma scintigraphy. This second study used the same technique with both fasted and fed human subjects. Size 0 capsules were filled with powder plugs made from lactose and did not contain croscarmellose as in the original study. The capsules were separately radiolabelled with indium-111 and technetium-99m. Both capsules were administered simultaneously with 180ml water to eight healthy male subjects following an overnight fast. Each volunteer was positioned in front of the gamma camera and sequential 60s images were acquired in a continuous manner for 30min. The mean (±S.D.) disintegration time in the fasted state for the hypromellose(carrageenan) capsules was 8±2min and for gelatin 7±3min. These results were not statistically different from the data in the original study and show that the removal of the croscarmellose had no effect on the results. The mean (±S.D.) disintegration time in the fed state for the hypromellose(carrageenan) capsules was 16±5min and for the gelatin capsules was 12±4min. There was no statistical difference between the hypromellose(carrageenan) and gelatin capsules in either the fed or fasted state.

  16. Pneumatic fractures in Confined Granular Media

    NASA Astrophysics Data System (ADS)

    Eriksen, Fredrik K.; Toussaint, Renaud; Jørgen Måløy, Knut; Grude Flekkøy, Eirik; Turkaya, Semih

    2016-04-01

    We will present our ongoing study of the patterns formed when air flows into a dry, non-cohesive porous medium confined in a horizontal Hele-Shaw cell. This is an optically transparent system consisting of two glass plates separated by 0.5 to 1 mm, containing a packing of dry 80 micron beads in between. The cell is rectangular and has an air-permeable boundary (blocking beads) at one short edge, while the other three edges are completely sealed. The granular medium is loosely packed against the semi-permeable boundary and fills about 80 % of the cell volume. This leaves an empty region at the sealed side, where an inlet allows us to set and maintain the air at a constant overpressure (0.1 - 2 bar). For the air trapped inside the cell to relax its overpressure it has to move through the deformable granular medium. Depending on the applied overpressure and initial density of the medium, we observe a range of different behaviors such as seepage through the pore-network with or without an initial compaction of the solid, formation of low density bubbles with rearrangement of particles, granular fingering/fracturing, and erosion inside formed channels/fractures. The experiments are recorded with a high-speed camera at a framerate of 1000 images/s and a resolution of 1024x1024 pixels. We use various image processing techniques to characterize the evolution of the air invasion patterns and the deformations in the surrounding material. The experiments are similar to deformation processes in porous media which are driven by pore fluid overpressure, such as mud volcanoes and hydraulic or pneumatic (gas-induced) fracturing, and the motivation is to increase the understanding of such processes by optical observations. In addition, this setup is an experimental version of the numerical models analyzed by Niebling et al. [1,2], and is useful for comparison with their results. In a directly related project [3], acoustic emissions from the cell plate are recorded during

  17. 78 FR 70623 - Pipeline Safety: Meeting of the Gas Pipeline Advisory Committee and the Liquid Pipeline Advisory...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-11-26

    ... the Liquid Pipeline Advisory Committee AGENCY: Pipeline and Hazardous Materials Safety Administration... Safety Standards Committee, and the Liquid Pipeline Advisory Committee (LPAC) also known as the Technical Hazardous Liquid Pipeline Safety Standards Committee. The committees will meet in a joint session...

  18. Maglev crude oil pipeline

    NASA Technical Reports Server (NTRS)

    Knolle, Ernst G.

    1994-01-01

    This maglev crude oil pipeline consists of two conduits guiding an endless stream of long containers. One conduit carries loaded containers and the other empty returns. The containers are levitated by permanent magnets in repulsion and propelled by stationary linear induction motors. The containers are linked to each other in a manner that allows them, while in continuous motion, to be folded into side by side position at loading and unloading points. This folding causes a speed reduction in proportion to the ratio of container diameter to container length. While in side by side position, containers are opened at their ends to be filled or emptied. Container size and speed are elected to produce a desired carrying capacity.

  19. INTERNAL REPAIR OF PIPELINES

    SciTech Connect

    Robin Gordon; Bill Bruce; Ian Harris; Dennis Harwig; George Ritter; Bill Mohr; Matt Boring; Nancy Porter; Mike Sullivan; Chris Neary

    2004-12-31

    The two broad categories of fiber-reinforced composite liner repair and deposited weld metal repair technologies were reviewed and evaluated for potential application for internal repair of gas transmission pipelines. Both are used to some extent for other applications and could be further developed for internal, local, structural repair of gas transmission pipelines. Principal conclusions from a survey of natural gas transmission industry pipeline operators can be summarized in terms of the following performance requirements for internal repair: (1) Use of internal repair is most attractive for river crossings, under other bodies of water, in difficult soil conditions, under highways, under congested intersections, and under railway crossings. (2) Internal pipe repair offers a strong potential advantage to the high cost of horizontal direct drilling when a new bore must be created to solve a leak or other problem. (3) Typical travel distances can be divided into three distinct groups: up to 305 m (1,000 ft.); between 305 m and 610 m (1,000 ft. and 2,000 ft.); and beyond 914 m (3,000 ft.). All three groups require pig-based systems. A despooled umbilical system would suffice for the first two groups which represents 81% of survey respondents. The third group would require an onboard self-contained power unit for propulsion and welding/liner repair energy needs. (4) The most common size range for 80% to 90% of operators surveyed is 508 mm (20 in.) to 762 mm (30 in.), with 95% using 558.8 mm (22 in.) pipe. Evaluation trials were conducted on pipe sections with simulated corrosion damage repaired with glass fiber-reinforced composite liners, carbon fiber-reinforced composite liners, and weld deposition. Additional un-repaired pipe sections were evaluated in the virgin condition and with simulated damage. Hydrostatic failure pressures for pipe sections repaired with glass fiber-reinforced composite liner were only marginally greater than that of pipe sections without

  20. INTERNAL REPAIR OF PIPELINES

    SciTech Connect

    Robin Gordon; Bill Bruce; Ian Harris; Dennis Harwig; Nancy Porter; Mike Sullivan; Chris Neary

    2004-04-12

    The two broad categories of deposited weld metal repair and fiber-reinforced composite liner repair technologies were reviewed for potential application for internal repair of gas transmission pipelines. Both are used to some extent for other applications and could be further developed for internal, local, structural repair of gas transmission pipelines. Preliminary test programs were developed for both deposited weld metal repair and for fiber-reinforced composite liner repair. Evaluation trials have been conducted using a modified fiber-reinforced composite liner provided by RolaTube and pipe sections without liners. All pipe section specimens failed in areas of simulated damage. Pipe sections containing fiber-reinforced composite liners failed at pressures marginally greater than the pipe sections without liners. The next step is to evaluate a liner material with a modulus of elasticity approximately 95% of the modulus of elasticity for steel. Preliminary welding parameters were developed for deposited weld metal repair in preparation of the receipt of Pacific Gas & Electric's internal pipeline welding repair system (that was designed specifically for 559 mm (22 in.) diameter pipe) and the receipt of 559 mm (22 in.) pipe sections from Panhandle Eastern. The next steps are to transfer welding parameters to the PG&E system and to pressure test repaired pipe sections to failure. A survey of pipeline operators was conducted to better understand the needs and performance requirements of the natural gas transmission industry regarding internal repair. Completed surveys contained the following principal conclusions: (1) Use of internal weld repair is most attractive for river crossings, under other bodies of water, in difficult soil conditions, under highways, under congested intersections, and under railway crossings. (2) Internal pipe repair offers a strong potential advantage to the high cost of horizontal direct drilling (HDD) when a new bore must be created to

  1. INTERNAL REPAIR OF PIPELINES

    SciTech Connect

    Robin Gordon; Bill Bruce; Ian Harris; Dennis Harwig; George Ritter; Bill Mohr; Matt Boring; Nancy Porter; Mike Sullivan; Chris Neary

    2004-08-17

    The two broad categories of fiber-reinforced composite liner repair and deposited weld metal repair technologies were reviewed and evaluated for potential application for internal repair of gas transmission pipelines. Both are used to some extent for other applications and could be further developed for internal, local, structural repair of gas transmission pipelines. Principal conclusions from a survey of natural gas transmission industry pipeline operators can be summarized in terms of the following performance requirements for internal repair: (1) Use of internal repair is most attractive for river crossings, under other bodies of water, in difficult soil conditions, under highways, under congested intersections, and under railway. (2) Internal pipe repair offers a strong potential advantage to the high cost of horizontal direct drilling when a new bore must be created to solve a leak or other problem. (3) Typical travel distances can be divided into three distinct groups: up to 305 m (1,000 ft.); between 305 m and 610 m (1,000 ft. and 2,000 ft.); and beyond 914 m (3,000 ft.). All three groups require pig-based systems. A despooled umbilical system would suffice for the first two groups which represents 81% of survey respondents. The third group would require an onboard self-contained power unit for propulsion and welding/liner repair energy needs. (4) The most common size range for 80% to 90% of operators surveyed is 508 mm (20 in.) to 762 mm (30 in.), with 95% using 558.8 mm (22 in.) pipe. Evaluation trials were conducted on pipe sections with simulated corrosion damage repaired with glass fiber-reinforced composite liners, carbon fiber-reinforced composite liners, and weld deposition. Additional un-repaired pipe sections were evaluated in the virgin condition and with simulated damage. Hydrostatic failure pressures for pipe sections repaired with glass fiber-reinforced composite liner were only marginally greater than that of pipe sections without liners

  2. Reconfigurable pipelined processor

    SciTech Connect

    Saccardi, R.J.

    1989-09-19

    This patent describes a reconfigurable pipelined processor for processing data. It comprises: a plurality of memory devices for storing bits of data; a plurality of arithmetic units for performing arithmetic functions with the data; cross bar means for connecting the memory devices with the arithmetic units for transferring data therebetween; at least one counter connected with the cross bar means for providing a source of addresses to the memory devices; at least one variable tick delay device connected with each of the memory devices and arithmetic units; and means for providing control bits to the variable tick delay device for variably controlling the input and output operations thereof to selectively delay the memory devices and arithmetic units to align the data for processing in a selected sequence.

  3. Preparation of polyurea capsules using electrocapillary emulsification.

    PubMed

    Sakai, Hideki; Tanaka, Keisuke; Fukushima, Hiroshi; Tsuchiya, Koji; Sakai, Kenichi; Kondo, Tamotsu; Abe, Masahiko

    2008-10-15

    Polyurea capsules have been prepared using the electrocapillary emulsification method in order to control the particle size within the submicron range. The polyurea capsules have been synthesized via the interfacial polycondensation between tetraethylenepentamine (TEP) dissolved in an aqueous phase and toluenediisocyanate (TDI) dissolved in a mixture of cyclohexane and chloroform. The oil phase contains a lipophilic nonionic surfactant (sorbitan sesquioleate, SO-15) as an emulsion stabilizer. Scanning electron microscope (SEM) observations reveal that the capsule size is decreased as (i) the amount of the aqueous phase injected into the oil phase is decreased and (ii) the dropping rate of the aqueous phase is decreased. Indeed, the mole ratio of the two monomers makes a significant impact on the capsule size. Under the best experimental condition examined in this study, we obtained polyurea capsules with a diameter of approximately 200nm, which should be useful in developing bioreactors or carriers.

  4. Thermoregulation of capsule production by Streptococcus pyogenes.

    PubMed

    Kang, Song Ok; Wright, Jordan O; Tesorero, Rafael A; Lee, Hyunwoo; Beall, Bernard; Cho, Kyu Hong

    2012-01-01

    The capsule of Streptococcus pyogenes serves as an adhesin as well as an anti-phagocytic factor by binding to CD44 on keratinocytes of the pharyngeal mucosa and the skin, the main entry sites of the pathogen. We discovered that S. pyogenes HSC5 and MGAS315 strains are further thermoregulated for capsule production at a post-transcriptional level in addition to the transcriptional regulation by the CovRS two-component regulatory system. When the transcription of the hasABC capsular biosynthetic locus was de-repressed through mutation of the covRS system, the two strains, which have been used for pathogenesis studies in the laboratory, exhibited markedly increased capsule production at sub-body temperature. Employing transposon mutagenesis, we found that CvfA, a previously identified membrane-associated endoribonuclease, is required for the thermoregulation of capsule synthesis. The mutation of the cvfA gene conferred increased capsule production regardless of temperature. However, the amount of the capsule transcript was not changed by the mutation, indicating that a post-transcriptional regulator mediates between CvfA and thermoregulated capsule production. When we tested naturally occurring invasive mucoid strains, a high percentage (11/53, 21%) of the strains exhibited thermoregulated capsule production. As expected, the mucoid phenotype of these strains at sub-body temperature was due to mutations within the chromosomal covRS genes. Capsule thermoregulation that exhibits high capsule production at lower temperatures that occur on the skin or mucosal surface potentially confers better capability of adhesion and invasion when S. pyogenes penetrates the epithelial surface.

  5. Thermoregulation of Capsule Production by Streptococcus pyogenes

    PubMed Central

    Kang, Song Ok; Wright, Jordan O.; Tesorero, Rafael A.; Lee, Hyunwoo; Beall, Bernard; Cho, Kyu Hong

    2012-01-01

    The capsule of Streptococcus pyogenes serves as an adhesin as well as an anti-phagocytic factor by binding to CD44 on keratinocytes of the pharyngeal mucosa and the skin, the main entry sites of the pathogen. We discovered that S. pyogenes HSC5 and MGAS315 strains are further thermoregulated for capsule production at a post-transcriptional level in addition to the transcriptional regulation by the CovRS two-component regulatory system. When the transcription of the hasABC capsular biosynthetic locus was de-repressed through mutation of the covRS system, the two strains, which have been used for pathogenesis studies in the laboratory, exhibited markedly increased capsule production at sub-body temperature. Employing transposon mutagenesis, we found that CvfA, a previously identified membrane-associated endoribonuclease, is required for the thermoregulation of capsule synthesis. The mutation of the cvfA gene conferred increased capsule production regardless of temperature. However, the amount of the capsule transcript was not changed by the mutation, indicating that a post-transcriptional regulator mediates between CvfA and thermoregulated capsule production. When we tested naturally occurring invasive mucoid strains, a high percentage (11/53, 21%) of the strains exhibited thermoregulated capsule production. As expected, the mucoid phenotype of these strains at sub-body temperature was due to mutations within the chromosomal covRS genes. Capsule thermoregulation that exhibits high capsule production at lower temperatures that occur on the skin or mucosal surface potentially confers better capability of adhesion and invasion when S. pyogenes penetrates the epithelial surface. PMID:22615992

  6. Toughness requirements for pipeline integrity

    SciTech Connect

    Denys, R.M.

    1995-12-31

    Experimental results of large scale (curved wide plate) tests on thin wall pipelines (thickness < 12.7 mm) have been compared with small scale (Charpy V notch impact and CTOD) test results. The result of the comparisons show that (a) the Charpy V notch impact test can be used to predict plastic collapse by pipe metal yielding of pipelines containing surface breaking root cracks and (b) the CTOD test should not be used as a basis for designing thin wall pipelines against brittle fracture. The assessment has further demonstrated that the effect of weld metal yield strength on the required minimum CVN or CTOD is an important factor.

  7. Natural gas pipeline technology overview.

    SciTech Connect

    Folga, S. M.; Decision and Information Sciences

    2007-11-01

    The United States relies on natural gas for one-quarter of its energy needs. In 2001 alone, the nation consumed 21.5 trillion cubic feet of natural gas. A large portion of natural gas pipeline capacity within the United States is directed from major production areas in Texas and Louisiana, Wyoming, and other states to markets in the western, eastern, and midwestern regions of the country. In the past 10 years, increasing levels of gas from Canada have also been brought into these markets (EIA 2007). The United States has several major natural gas production basins and an extensive natural gas pipeline network, with almost 95% of U.S. natural gas imports coming from Canada. At present, the gas pipeline infrastructure is more developed between Canada and the United States than between Mexico and the United States. Gas flows from Canada to the United States through several major pipelines feeding U.S. markets in the Midwest, Northeast, Pacific Northwest, and California. Some key examples are the Alliance Pipeline, the Northern Border Pipeline, the Maritimes & Northeast Pipeline, the TransCanada Pipeline System, and Westcoast Energy pipelines. Major connections join Texas and northeastern Mexico, with additional connections to Arizona and between California and Baja California, Mexico (INGAA 2007). Of the natural gas consumed in the United States, 85% is produced domestically. Figure 1.1-1 shows the complex North American natural gas network. The pipeline transmission system--the 'interstate highway' for natural gas--consists of 180,000 miles of high-strength steel pipe varying in diameter, normally between 30 and 36 inches in diameter. The primary function of the transmission pipeline company is to move huge amounts of natural gas thousands of miles from producing regions to local natural gas utility delivery points. These delivery points, called 'city gate stations', are usually owned by distribution companies, although some are owned by transmission companies

  8. Proceedings of the pipeline engineering symposium - 1986

    SciTech Connect

    Seiders, E.J.

    1986-01-01

    This book presents the papers given at a symposium on the transport of petroleum and natural gas through pipelines. Topics considered at the symposium included explosion welding, flash-butt welding, computerized welding, flow improvers, carbon dioxide pipelines, submarine pipelines, computer-aided design, repair, reinforced concrete, monitoring, storage, waste processing, and gas condensate pipelines.

  9. 27 CFR 24.169 - Pipelines.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 1 2012-04-01 2012-04-01 false Pipelines. 24.169 Section... THE TREASURY LIQUORS WINE Construction and Equipment § 24.169 Pipelines. Pipelines, including flexible.... The appropriate TTB officer may approve pipelines which cannot be readily examined if no jeopardy...

  10. 27 CFR 24.169 - Pipelines.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 1 2014-04-01 2014-04-01 false Pipelines. 24.169 Section... THE TREASURY ALCOHOL WINE Construction and Equipment § 24.169 Pipelines. Pipelines, including flexible.... The appropriate TTB officer may approve pipelines which cannot be readily examined if no jeopardy...

  11. 27 CFR 24.169 - Pipelines.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 1 2010-04-01 2010-04-01 false Pipelines. 24.169 Section... THE TREASURY LIQUORS WINE Construction and Equipment § 24.169 Pipelines. Pipelines, including flexible.... The appropriate TTB officer may approve pipelines which cannot be readily examined if no jeopardy...

  12. 27 CFR 24.169 - Pipelines.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 1 2013-04-01 2013-04-01 false Pipelines. 24.169 Section... THE TREASURY ALCOHOL WINE Construction and Equipment § 24.169 Pipelines. Pipelines, including flexible.... The appropriate TTB officer may approve pipelines which cannot be readily examined if no jeopardy...

  13. 27 CFR 24.169 - Pipelines.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 1 2011-04-01 2011-04-01 false Pipelines. 24.169 Section... THE TREASURY LIQUORS WINE Construction and Equipment § 24.169 Pipelines. Pipelines, including flexible.... The appropriate TTB officer may approve pipelines which cannot be readily examined if no jeopardy...

  14. 77 FR 5472 - Pipeline Safety: Miscellaneous Changes to Pipeline Safety Regulations

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-02-03

    ... Pipeline and Hazardous Materials Safety Administration 49 CFR Parts 191, 192 and 195 RIN 2137-AE59 Pipeline Safety: Miscellaneous Changes to Pipeline Safety Regulations AGENCY: Pipeline and Hazardous Materials... titled: ``Miscellaneous Changes to Pipeline Safety Regulations'' seeking comments on the need for...

  15. 75 FR 72877 - Pipeline Safety: Updates to Pipeline and Liquefied Natural Gas Reporting Requirements

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-11-26

    ... Safety: Updates to Pipeline and Liquefied Natural Gas Reporting Requirements; Final Rule #0;#0;Federal... to Pipeline and Liquefied Natural Gas Reporting Requirements AGENCY: Pipeline and Hazardous Materials... collections from operators of natural gas pipelines, hazardous liquid pipelines, and liquefied natural......

  16. 77 FR 36606 - Pipeline Safety: Government/Industry Pipeline Research and Development Forum, Public Meeting

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-06-19

    ... Pipeline and Hazardous Materials Safety Administration Pipeline Safety: Government/Industry Pipeline... a Government/Industry Pipeline Research and Development (R&D) Forum. The R&D Forums are held... pipeline safety and with protecting the environment. The forum allows public, government and...

  17. Hydrodynamick instabilities on ICF capsules

    SciTech Connect

    Haan, S.W.

    1991-06-07

    This article summarizes our current understanding of hydrodynamic instabilities as relevant to ICF. First we discuss classical, single mode Rayleigh-Taylor instability, and nonlinear effects in the evolution of a single mode. Then we discuss multimode systems, considering: (1) the onset of nonlinearity; (2) a second order mode coupling theory for weakly nonlinear effects, and (3) the fully nonlinear regime. Two stabilization mechanisms relevant to ICF are described next: gradient scale length and convective stabilization. Then we describe a model which is meant to estimate the weakly nonlinear evolution of multi-mode systems as relevant to ICF, given the short-wavelength stabilization. Finally, we discuss the relevant code simulation capability, and experiments. At this time we are quite optimistic about our ability to estimate instability growth on ICF capsules, but further experiments and simulations are needed to verify the modeling. 52 refs.

  18. Nondestructive characterization of pipeline materials

    NASA Astrophysics Data System (ADS)

    Engle, Brady J.; Smart, Lucinda J.; Bond, Leonard J.

    2015-03-01

    There is a growing need to quantitatively and nondestructively evaluate the strength and toughness properties of pipeline steels, particularly in aging pipeline infrastructure. These strength and toughness properties, namely yield strength, tensile strength, transition temperature, and toughness, are essential for determining the safe operating pressure of the pipelines. For some older pipelines crucial information can be unknown, which makes determining the pressure rating difficult. Current inspection techniques address some of these issues, but they are not comprehensive. This paper will briefly discuss current inspection techniques and relevant literature for relating nondestructive measurements to key strength and toughness properties. A project is in progress to provide new in-trench tools that will give strength properties without the need for sample removal and destructive testing. Preliminary experimental ultrasonic methods and measurements will be presented, including velocity, attenuation, and backscatter measurements.

  19. Pipelines programming paradigms: Prefab plumbing

    SciTech Connect

    Boeheim, C.

    1991-08-01

    Mastery of CMS Pipelines is a process of learning increasingly sophisticated tools and techniques that can be applied to your problem. This paper presents a compilation of techniques that can be used as a reference for solving similar problems

  20. [Evaluation of nopal capsules in diabetes mellitus].

    PubMed

    Frati Munari, A C; Vera Lastra, O; Ariza Andraca, C R

    1992-01-01

    To find out if commercial capsules with dried nopal (prickle-pear cactus, Opuntia ficus indica may have a role in the management of diabetes mellitus, three experiments were performed: 30 capsules where given in fasting condition to 10 diabetic subjects and serum glucose was measured through out 3 hours; a control test was performed with 30 placebo capsules. OGTT with previous intake of 30 nopal or placebo capsules was performed in ten healthy individuals. In a crossover and single blinded study 14 diabetic patients withdrew the oral hypoglycemic treatment and received 10 nopal or placebo capsules t.i.d. during one week; serum glucose, cholesterol and tryglycerides levels were measured before and after each one-week period. Five healthy subjects were also studied in the same fashion. Opuntia capsules did not show acute hypoglycemic effect and did not influence OGTT. In diabetic patients serum glucose, cholesterol and tryglycerides levels did not change with Opuntia, but they increased with placebo (P < 0.01 glucose and cholesterol, P = NS triglycerides). In healthy individuals glycemia did not change with nopal, while cholesterol and triglycerides decreased (P < 0.01 vs. placebo). The intake of 30 Opuntia capsules daily in patients with diabetes mellitus had a discrete beneficial effect on glucose and cholesterol. However this dose is unpractical and at present it is not recommended in the management of diabetes mellitus.

  1. Indicator Expansion with Analysis Pipeline

    DTIC Science & Technology

    2015-01-13

    2014 Carnegie Mellon University Indicator Expansion with Analysis Pipeline Dan Ruef 1/13/15 Report Documentation Page Form ApprovedOMB No. 0704...4. TITLE AND SUBTITLE Indicator Expansion with Analysis Pipeline 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR(S...Mellon®, CERT® and FloCon® are registered marks of Carnegie Mellon University. DM-0002067 3 Definition “Indicator expansion is a process of using one or

  2. Neuro-Fuzzy Control for Pneumatic Servo System

    NASA Astrophysics Data System (ADS)

    Shibata, Satoru; Jindai, Mitsuru; Yamamoto, Tomonori; Shimizu, Akira

    A learning method for acquiring the appropriate fuzzy rules using error back propagation to improve the control performance of the pneumatic servo system is presented in this paper. In the proposed method, two criteria are defined and are adjusted so as to minimize them using error back propagation. These criteria are defined on the fuzzy rules, that is, shapes of membership functions of antecedent clause and real values of consequent clause in the fuzzy controller. Two differentiating coefficients of the plant, used in error back propagation with respect to those criteria, are estimated by the newly established neural network. Moreover, sigmoid function is introduced for the connection of the neural network to compensate for the effect of non-linearity of the system. The method was applied to an existent vertical type pneumatic servo system and proved its effectiveness for practical use.

  3. Massive Pulmonary Calculi Embolism: A Novel Complication of Pneumatic Lithotripsy

    PubMed Central

    Zhang, Lin; Zhou, Yiwu

    2015-01-01

    Abstract Pneumatic lithotripsy is a minimally invasive technique mainly for the treatment of urinary staghorn stones. Previous literatures have reported some therapeutic complications during or after this procedure, but calculi embolism has not been mentioned before. We report here a fatal case of calculi-induced pulmonary embolism in an adult woman who underwent pneumatic lithotripsy. An autopsy did not reveal any evidence of pulmonary embolism. However, light microscopy revealed noticeable presence of calculi in pulmonary arterioles and capillaries, as evidenced by environmental scanning electron microscope and energy dispersive X-ray analysis. The primary determinants of calculi embolism include intrarenal pressure, and volume and viscosity of the calculi fragments formation. Vascular intravasation of smashed calculi might increase pulmonary vascular resistance and hypoxemia and decrease cardiac output. This case report intends to provide information for clinicians to consider the probability of intraoperative calculi embolism during lithotripsies when patients develop typical symptoms of acute pulmonary embolism. PMID:26222867

  4. Pneumatic Regolith Transfer Systems for In-Situ Resource Utilization

    NASA Technical Reports Server (NTRS)

    Mueller, Robert P.; Townsend, Ivan I., III; Mantovani, James G.

    2010-01-01

    One aspect of In-Situ Resource Utilization (lSRU) in a lunar environment is to extract oxygen and other elements from the minerals that make up the lunar regolith. Typical ISRU oxygen production processes include but are not limited to hydrogen reduction, carbothermal and molten oxide electrolysis. All of these processes require the transfer of regolith from a supply hopper into a reactor for chemical reaction processing, and the subsequent extraction of the reacted regolith from the reactor. This paper will discuss recent activities in the NASA ISRU project involved with developing pneumatic conveying methods to achieve lunar regolith simulant transfer under I-g and 1/6-g gravitational environments. Examples will be given of hardware that has been developed and tested by NASA on reduced gravity flights. Lessons learned and details of pneumatic regolith transfer systems will be examined as well as the relative performance in a 1/6th G environment

  5. Development of pneumatic thrust-deflecting powered-lift systems

    NASA Technical Reports Server (NTRS)

    Englar, R. J.; Nichols, J. H., Jr.; Harris, M. J.; Eppel, J. C.; Shovlin, M. D.

    1986-01-01

    Improvements introduced into the Circulation Control Wing/Upper Surface Blowing (CCW/USB) STOL concept (Harris et al., 1982) are described along with results of the full-scale static ground tests and model-scale wind tunnel investigations. Tests performed on the full-scale pneumatic thrust-deflecting system installed on the NASA QSRA aircraft have demonstrated that, relative to the original baseline configuration, a doubling of incremental thrust deflection due to blowing resulted from improvements that increased the blowing span and momentum, as well as from variations in blowing slot height and geometry of the trailing edge. A CCW/Over the Wing model has been built and tested, which was shown to be equivalent to the CCW/USB system in terms of pneumatic thrust deflection and lift generation, while resolving the problem of cruise thrust loss due to exhaust scrubbing on the wing upper surface.

  6. Liquid-metal dip seal with pneumatic spring

    DOEpatents

    Poindexter, Allan M.

    1977-01-01

    An improved liquid-metal dip seal for sealing the annulus between rotating plugs in the reactor vessel head of a liquid-metal fast-breeder nuclear reactor has two legs of differing widths communicating under a seal blade; the wide leg is also in communication with cover gas of the reactor and the narrow leg is also in communication with an isolated plug annulus above the seal. The annulus contains inert gas which acts as a pneumatic spring. Upon increasing cover gas pressure which depresses the level in the wide leg and greatly increases the level in the narrow leg, the pneumatic spring is compressed, and resists further level changes, thus preventing radioactive cover gas from bubbling through the seal.

  7. Pneumatic protection applied to an airbag for para-gliders

    NASA Astrophysics Data System (ADS)

    Raievski, V.; Valladas, G.

    1998-02-01

    We present a theory of pneumatic protection based on the laws of thermodynamics, elasticity and fluid mechanics. A general pneumatic protection system is made up of several communicating compartments, the differences in pressure of the compartments generating a transfer of mass and energy between them. The transfer offers interesting possibilities to improve the performance of the system. An example of this type of protection in aerial sport is the airbag for para-gliders, it is used in this paper to illustrate the theory. As the pressure in the airbag depends uniquely on its volume, the geometric model in the theory can be simplified. Experiments carried out with crash-test dummies equipped with sensors have confirmed the theoretical predictions.

  8. A skin indentation system using a pneumatic bellows.

    PubMed

    Ferguson-Pell, M; Hagisawa, S; Masiello, R D

    1994-01-01

    A pneumatic indentation system using a copper bellows has been developed for physiological studies where a controlled uniaxial compressive force is required to be applied to the surface of the skin. Such a system is useful for studies where the physiological response of the tissues is to be monitored following a known loading history. The indentation system is driven by a vacuum/compression pneumatic pump through solenoid valves under closed-loop computer control. A load cell placed between the indentor and bellows monitors the applied force providing a feedback signal to the computer. The signal from the computer activates the valves supplying air pressure to the bellows, and the applied force is controlled using a digital closed-loop protocol. This system can be used to provide a controlled loading sequence to the skin without utilizing gravitational forces, which allows the subject to keep a more natural position during the experiment.

  9. Asymmetric membrane osmotic capsules for terbutaline sulphate.

    PubMed

    Gobade, N G; Koland, Marina; Harish, K H

    2012-01-01

    The aim of the present study was to design an asymmetric membrane capsule, an osmotic pump-based drug delivery system of ethyl cellulose for controlled release of terbutaline sulphate. asymmetric membrane capsules contains pore-forming water soluble additive, sorbitol in different concentrations in the capsule shell membrane, which after coming in contact with water, dissolves, resulting in an in situ formation of a microporous structure. The terbutaline sulphate is a β-adrenoreceptor agonist widely used in the treatment of asthma. The oral dosage regimen of terbutaline sulphate is 5 mg twice or thrice daily, the plasma half-life is approximate 3-4 h and it produces GI irritation with extensive first pass metabolism. Hence, terbutaline sulphate was chosen as a model drug with an aim to develop controlled release system. Different formulations of ethyl cellulose were prepared by phase inversion technique using different concentrations of sorbitol as pore forming agent. It was found that the thickness of the prepared asymmetric membrane capsules was increased with increase in concentration of ethyl cellulose and pore forming agent, i.e. sorbitol. The dye release study in water and 10% sodium chloride solution indicates that, the asymmetric membrane capsules follow osmotic principle to release content. The pores formed due to sorbitol were confirmed by microscopic observation of transverse section of capsule membrane. Data of in vitro release study of terbutaline sulphate from asymmetric membrane capsules indicated that, the capsules prepared with 10% and 12.5% of ethyl cellulose and 25% of sorbitol released as much as 97.44% and 76.27% in 12 h, respectively with zero order release rate. Hence asymmetric membrane capsule of 10% ethyl cellulose and 25% of sorbitol is considered as optimum for controlled oral delivery of terbutaline sulphate.

  10. Asymmetric Membrane Osmotic Capsules for Terbutaline Sulphate

    PubMed Central

    Gobade, N. G.; Koland, Marina; Harish, K. H.

    2012-01-01

    The aim of the present study was to design an asymmetric membrane capsule, an osmotic pump-based drug delivery system of ethyl cellulose for controlled release of terbutaline sulphate. asymmetric membrane capsules contains pore-forming water soluble additive, sorbitol in different concentrations in the capsule shell membrane, which after coming in contact with water, dissolves, resulting in an in situ formation of a microporous structure. The terbutaline sulphate is a β-adrenoreceptor agonist widely used in the treatment of asthma. The oral dosage regimen of terbutaline sulphate is 5 mg twice or thrice daily, the plasma half-life is approximate 3-4 h and it produces GI irritation with extensive first pass metabolism. Hence, terbutaline sulphate was chosen as a model drug with an aim to develop controlled release system. Different formulations of ethyl cellulose were prepared by phase inversion technique using different concentrations of sorbitol as pore forming agent. It was found that the thickness of the prepared asymmetric membrane capsules was increased with increase in concentration of ethyl cellulose and pore forming agent, i.e. sorbitol. The dye release study in water and 10% sodium chloride solution indicates that, the asymmetric membrane capsules follow osmotic principle to release content. The pores formed due to sorbitol were confirmed by microscopic observation of transverse section of capsule membrane. Data of in vitro release study of terbutaline sulphate from asymmetric membrane capsules indicated that, the capsules prepared with 10% and 12.5% of ethyl cellulose and 25% of sorbitol released as much as 97.44% and 76.27% in 12 h, respectively with zero order release rate. Hence asymmetric membrane capsule of 10% ethyl cellulose and 25% of sorbitol is considered as optimum for controlled oral delivery of terbutaline sulphate. PMID:23204625

  11. Oxygen fugacity and piston cylinder capsule assemblies

    NASA Astrophysics Data System (ADS)

    Jakobsson, S.

    2011-12-01

    A double capsule assembly designed to control oxygen fugacity in piston cylinder experiments has been tested at 1200 °C and 10 kbar. The assembly consists of an outer Pt-capsule containing a solid buffer (Ni-NiO or Co-CoO plus H2O) and an inner AuPd-capsule containing the sample, H2O and a Pt-wire. To prevent direct contact with the buffer phases the AuPd-capsule is embedded in finely ground Al2O3 along with some coarser, fractured Al2O3 facilitating fluid inclusion formation. No water loss is observed in the sample even after 48 hrs but a slight increase in water content is observed in longer duration runs due to oxygen and hydrogen diffusion into the AuPd-capsule. Carbon from the furnace also diffuses through the outer Pt-capsule but reacts with H2O in the outer capsule to form CO2 and never reaches the inner capsule. Oxygen fugacity of runs in equilibrium with the Ni-NiO and Co-CoO buffers was measured by analyzing the Fe content of the Pt-wire in the sample1 and by analyzing Fe dissolved in the AuPd capsule2. The second method gives values that are in good agreement with established buffer whereas results from the first method are one half to one log units higher than the established values. References 1. E. Medard, C. A. McCammon, J. A. Barr, T. L. Grove, Am. Mineral. 93, 1838 (2008). 2. J. Barr, T. Grove, Contrib. Mineral. Petrol. 160, 631 (2010)

  12. Transport of methanol by pipeline

    SciTech Connect

    Not Available

    1985-04-01

    This report examines and evaluates the problems and considerations that could affect the feasibility of transporting methanol by pipeline. The following are the major conclusions: Though technical problems, such as methanol water contamination and materials incompatibility, remain to be solved, none appears insolvable. Methanol appears to be less toxic, and therefore to represent less of a health hazard, than gasoline, the fuel for which methanol is expected to substitute. The primary safety hazards of methanol, fire and explosion, are no worse than those of gasoline. The environmental hazards that can be associated with methanol are not as significant as those of petroleum. Provided quantities of throughput sufficient to justify pipeline transport are available, there appear to be no economic impediments to the transport of methanol by pipeline. Based on these, it appears that it can be concluded that the pipelining of methanol, whether via an existing petroleum pipeline or a new methanol-dedicated pipeline, is indeed feasible. 66 refs., 3 figs., 27 tabs.

  13. The LOFAR Pulsar Data Pipeline

    NASA Astrophysics Data System (ADS)

    Alexov, A.; Hessels, J.; Mol, J. D.; Stappers, B.; van Leeuwen, J.

    2010-12-01

    The LOw Frequency ARray (LOFAR) for radio astronomy is being built in the Netherlands by ASTRON, with extensions throughout Europe. LOFAR operates at radio frequencies below 250 MHz. The project is an interferometric array of radio antennas grouped into stations that are distributed over an area of hundreds of kilometers. LOFAR will revolutionise low-frequency radio astronomy. Transient radio phenomena and pulsars are one of six LOFAR Key Science Projects (KSPs). As part of the Transients KSP, the Pulsar Working Group has been developing the LOFAR Pulsar Data Pipeline to both study known pulsars as well as search for new ones. The pipeline is being developed for the Blue Gene/P (BG/P) supercomputer and a large Linux cluster in order to utilize enormous amounts of computation capabilities (˜ 50 Tflops) and data streams of up to 23TB/hour. The LOFAR pipeline output will be using the Hierarchical Data Format 5 (HDF5) to efficiently store large amounts of numerical data, and to manage complex data encompassing a variety of data types, across distributed storage and processing architectures. We present the LOFAR Pulsar Data Pipeline overview, the pulsar beam-formed data format, the status of the pipeline processing as well as our future plans for developing additional transient pipelines.

  14. VLT Instruments Pipeline System Overview

    NASA Astrophysics Data System (ADS)

    Jung, Y.; Ballester, P.; Banse, K.; Hummel, W.; Izzo, C.; McKay, D. J.; Kiesgen, M.; Lundin, L. K.; Modigliani, A.; Palsa, R. M.; Sabet, C.

    2004-07-01

    Since the beginning of the VLT operations in 1998, substantial effort has been put in the development of automatic data reduction tools for the VLT instruments. A VLT instrument pipeline is a complex system that has to be able to identify and classify each produced FITS file, optionally retrieve calibration files from a database, use an image processing software to reduce the data, compute and log quality control parameters, produce FITS images or tables with the correct headers, optionally display them in the control room and send them to the archive. Each instrument has its own dedicated pipeline, based on a common infrastructure and installed with the VLT Data Flow System (DFS). With the increase in the number and the complexity of supported instruments and in the rate of produced data, these pipelines are becoming vital for both the VLT operations and the users, and request more and more resources for development and maintenance. This paper describes the different pipeline tasks with some real examples. It also explains how the development process has been improved to both decrease its cost and increase the pipelines quality using the lessons learned from the first instruments pipelines development.

  15. A new sauropod dinosaur from the Early Cretaceous of Tunisia with extreme avian-like pneumatization.

    PubMed

    Fanti, Federico; Cau, Andrea; Hassine, Mohsen; Contessi, Michela

    2013-01-01

    Recent interpretations of the postcranial anatomy of sauropod dinosaurs differ about pneumatic features supporting an avian-like ventilatory system; the most conservative workers reject most postcranial pneumatizations as being unambiguous evidence of abdominal air sacs. Here we describe the first articulated dinosaur skeleton from Tunisia and refer it to a new rebbachisaurid sauropod, Tataouinea hannibalis gen. et sp. nov. The Tunisian specimen shows a complex pattern of caudosacral and pelvic pneumatization--including the first report of an ischial pneumatic foramen among Dinosauria--strongly supporting the presence of abdominal air sacs. Character optimization among Rebbachisauridae indicates that in the caudal vertebrae, pneumatization of the neural arches preceded that of the centra; in the pelvis, pneumatization of the bones adjacent to the sacrum preceded that of more distal elements. Tataouinea was more closely related to European nigersaurines than to otherwise Gondwanan rebbachisaurids; this supports an Afro-European route for rebbachisaurid dispersal.

  16. Development of robot hand with pneumatic actuator and construct of master-slave system.

    PubMed

    Nishino, Shinya; Tsujiuchi, Nobutaka; Koizumi, Takayuki; Komatsubara, Hiroyuki; Kudawara, Tatuwo; Shimizu, Mikio

    2007-01-01

    Recently, research has concentrated on robots that can coexist with people and be of use to them. Such a robot needs to be both safe and flexible. Here, we use a pneumatic actuator as the driving source of a robot hand. We develop a pneumatic actuator driven by low pressure because we consider that the conventional pneumatic actuator is inadequate for the driving source of a robot hand. First, we examine the characteristics of our new pneumatic actuator. Next, we develop a five-fingered robot hand using this pneumatic actuator. The robot hand produced is both safe and flexible. We construct a master-slave system to enable the robot hand to perform the same operations as a human hand. Next, we make a joint model that has one degree of freedom using a pneumatic actuator. We construct a control system for the joint model and verify its control performance.

  17. Dynamic Analysis of Sounding Rocket Pneumatic System Revision

    NASA Technical Reports Server (NTRS)

    Armen, Jerald

    2010-01-01

    The recent fusion of decades of advancements in mathematical models, numerical algorithms and curve fitting techniques marked the beginning of a new era in the science of simulation. It is becoming indispensable to the study of rockets and aerospace analysis. In pneumatic system, which is the main focus of this paper, particular emphasis will be placed on the efforts of compressible flow in Attitude Control System of sounding rocket.

  18. Comprehensive integration of homogeneous bioassays via centrifugo-pneumatic cascading.

    PubMed

    Godino, Neus; Gorkin, Robert; Linares, Ana V; Burger, Robert; Ducrée, Jens

    2013-02-21

    This work for the first time presents the full integration and automation concept for a range of bioassays leveraged by cascading a centrifugo-pneumatic valving scheme to sequentially move several liquids through shared channel segments for multi-step sample preparation into the detection zone. This novel centrifugo-pneumatic liquid handling significantly simplifies system manufacture by obviating the need for complex surface functionalization procedures or hybrid material integration, as it is common in conventional valving methods such as capillary burst valves or sacrificial valves. Based on the centrifugo-pneumatic valving scheme, this work presents a toolkit of operational elements implementing liquid loading/transfer, metering, mixing and sedimentation in a microstructured polymer disc. As a proof of concept for the broad class of homogeneous bioassays, the full integration and automation of a colorimetric nitrate/nitrite test for the detection of clinically relevant nitric oxide (NO) in whole blood is implemented. First, 40 μL of plasma is extracted from a 100 μL sample of human blood, incubated for one hour with the enzymatic mixture (60 μL), and finally reacted with 100 μL of colorimetric (Greiss) reagents. Following just a single loading phase at the beginning of the process, all of these steps are automated through the centrifugo-pneumatic cascade with a high level of flow control and synchronization. Our system shows good correlation with controls up to 50 μM of nitrate, which adequately covers the healthy human range (4 to 45.3 μM).

  19. Electric versus pneumatic power in hand prostheses for children.

    PubMed

    Plettenburg, D H

    1989-01-01

    Most externally powered hand prostheses for children with a unilateral congenital below-elbow amputation are myoelectrically controlled. All of them are electrically powered. Despite the success of fitting children with this kind of prostheses, there are some disadvantages: prosthetic weight is high, operating speed is low, the system is vulnerable and its size prohibits fitting it to patients with a long fore-arm stump. It will be shown that pneumatic power can overcome most of these disadvantages.

  20. Pneumatic Muscle Actuated Equipment for Continuous Passive Motion

    NASA Astrophysics Data System (ADS)

    Deaconescu, Tudor T.; Deaconescu, Andrea I.

    2009-10-01

    Applying continuous passive rehabilitation movements as part of the recovery programme of patients with post-traumatic disabilities of the bearing joints of the inferior limbs requires the development of new high performance equipment. This chapter discusses a study of the kinematics and performance of such a new, continuous passive motion based rehabilitation system actuated by pneumatic muscles. The utilized energy source is compressed air ensuring complete absorption of the end of stroke shocks, thus minimizing user discomfort.

  1. Tag gas capsule with magnetic piercing device

    DOEpatents

    Nelson, Ira V.

    1976-06-22

    An apparatus for introducing a tag (i.e., identifying) gas into a tubular nuclear fuel element. A sealed capsule containing the tag gas is placed in the plenum in the fuel tube between the fuel and the end cap. A ferromagnetic punch having a penetrating point is slidably mounted in the plenum. By external electro-magnets, the punch may be caused to penetrate a thin rupturable end wall of the capsule and release the tag gas into the fuel element. Preferably the punch is slidably mounted within the capsule, which is in turn loaded as a sealed unit into the fuel element.

  2. Fabrication of capsule assemblies, phase 3

    NASA Technical Reports Server (NTRS)

    Keeton, A. R.; Stemann, L. G.

    1973-01-01

    Thirteen capsule assemblies were fabricated for evaluation of fuel pin design concepts for a fast spectrum lithium cooled compact space power reactor. These instrumented assemblies were designed for real time test of prototype fuel pins. Uranium mononitride fuel pins were encased in AISI 304L stainless steel capsules. Fabrication procedures were fully qualified by process development and assembly qualification tests. Instrumentation reliability was achieved utilizing specially processed and closely controlled thermocouple hot zone fabrication and by thermal screening tests. Overall capsule reliability was achieved with an all electron beam welded assembly.

  3. STIS Calibration Pipeline

    NASA Astrophysics Data System (ADS)

    Hulbert, S.; Hodge, P.; Lindler, D.; Shaw, R.; Goudfrooij, P.; Katsanis, R.; Keener, S.; McGrath, M.; Bohlin, R.; Baum, S.

    1997-05-01

    Routine calibration of STIS observations in the HST data pipeline is performed by the CALSTIS task. CALSTIS can: subtract the over-scan region and a bias image from CCD observations; remove cosmic ray features from CCD observations; correct global nonlinearities for MAMA observations; subtract a dark image; and, apply flat field corrections. In the case of spectral data, CALSTIS can also: assign a wavelength to each pixel; apply a heliocentric correction to the wavelengths; convert counts to absolute flux; process the automatically generated spectral calibration lamp observations to improve the wavelength solution; rectify two-dimensional (longslit) spectra; subtract interorder and sky background; and, extract one-dimensional spectra. CALSTIS differs in significant ways from the current HST calibration tasks. The new code is written in ANSI C and makes use of a new C interface to IRAF. The input data, reference data, and output calibrated data are all in FITS format, using IMAGE or BINTABLE extensions. Error estimates are computed and include contributions from the reference images. The entire calibration can be performed by one task, but many steps can also be performed individually.

  4. Evaluation of unsaturated zone air permeability through pneumatic tests

    USGS Publications Warehouse

    Baehr, Arthur L.; Hult, Marc F.

    1991-01-01

    Predicting the steady state distribution of air pressure in the unsaturated zone resulting from a pneumatic test provides a method for determining air-phase permeability. This technique is analogous to the inverse problem of well hydraulics; however, air flow is more complicated than ground water flow because of air compressibility, the Klinkenberg effect, variations in air density and viscosity that result from temperature fluctuations in the unsaturated zone and the possibility of inducing water movement during the pneumatic test. An analysis of these complicating factors reveals that, when induced water movement can be neglected, a linear version of the airflow equation can provide an appropriate approximation for the purpose of determining air-phase permeability. Two analytical solutions for steady state, two-dimensional, axisymmetric airflow to a single well partially screened in the unsaturated zone are developed. One solution applies where there is a stratum of relatively low air permeability, separating the stratum in which the well is completed, from the atmosphere. The other solution applies where there is no separating stratum between the domain and atmosphere. In both situations the water table forms the lower horizontal boundary. Applications of both solutions to determine air permeability from data collected during pneumatic tests are presented.

  5. A Model-Based Prognostics Approach Applied to Pneumatic Valves

    NASA Technical Reports Server (NTRS)

    Daigle, Matthew J.; Goebel, Kai

    2011-01-01

    Within the area of systems health management, the task of prognostics centers on predicting when components will fail. Model-based prognostics exploits domain knowledge of the system, its components, and how they fail by casting the underlying physical phenomena in a physics-based model that is derived from first principles. Uncertainty cannot be avoided in prediction, therefore, algorithms are employed that help in managing these uncertainties. The particle filtering algorithm has become a popular choice for model-based prognostics due to its wide applicability, ease of implementation, and support for uncertainty management. We develop a general model-based prognostics methodology within a robust probabilistic framework using particle filters. As a case study, we consider a pneumatic valve from the Space Shuttle cryogenic refueling system. We develop a detailed physics-based model of the pneumatic valve, and perform comprehensive simulation experiments to illustrate our prognostics approach and evaluate its effectiveness and robustness. The approach is demonstrated using historical pneumatic valve data from the refueling system.

  6. A pneumatic orthotic cranial molding helmet for correcting positional plagiocephaly.

    PubMed

    Lee, Walter T; Richards, Kirsten; Redhed, James; Papay, Frank A

    2006-01-01

    The objective of this study was o determine the efficacy of a newly developed pneumatic orthotic cranial molding helmet for correcting positional plagiocephaly. The design was retrospective and the setting was a tertiary care center. Subjects were all patients in whom positional plagiocephaly has been diagnosed and who have been fitted by the Orthotics and Prosthetics Department for the helmet. Diagonal cranial lengths and widths were measured at each visit. Analysis included the calculation of the ratio change in oblique diameters compared with time, patient's age, and head circumference. Seventy-five patients met inclusion criteria (50 boys, 25 girls). Patients with pneumatic orthotic cranial molding helmet therapy had significantly improved outcomes as compared with pretreatment measurements (P < or = 0.0001). The helmet did not limit cranial growth as evidenced by significant normalization of the oblique measurement ratio when compared with increasing cranial circumference and age (P = 0.0003, P < or = 0.0001, respectively). The pneumatic orthotic cranial molding helmet successfully corrects positional plagiocephaly and does not hinder cranial growth.

  7. Design and Control of a Pneumatically Actuated Transtibial Prosthesis

    PubMed Central

    Zheng, Hao; Shen, Xiangrong

    2015-01-01

    This paper presents the design and control of a pneumatically actuated transtibial prosthesis, which utilizes a pneumatic cylinder-type actuator to power the prosthetic ankle joint to support the user's locomotion. The pneumatic actuator has multiple advantages over the traditional electric motor, such as light weight, low cost, and high power-to-weight ratio. The objective of this work is to develop a compact and lightweight transtibial prosthesis, leveraging the multiple advantages provided by this highly competitive actuator. In this paper, the design details of the prosthesis are described, including the determination of performance specifications, the layout of the actuation mechanism, and the calculation of the torque capacity. Through the authors’ design calculation, the prosthesis is able to provide sufficient range of motion and torque capacity to support the locomotion of a 75 kg individual. The controller design is also described, including the underlying biomechanical analysis and the formulation of the finite-state impedance controller. Finally, the human subject testing results are presented, with the data indicating that the prosthesis is able to generate a natural walking gait and sufficient power output for its amputee user. PMID:26146497

  8. Effect of pneumatic compression on fibrinolysis after total hip arthroplasty.

    PubMed

    Macaulay, William; Westrich, Geoffrey; Sharrock, Nigel; Sculco, Thomas P; Jhon, Peter H; Peterson, Margaret G E; Salvati, Eduardo A

    2002-06-01

    The purpose of this prospective randomized clinical study was to investigate the enhanced systemic fibrinolysis mechanism of venous thrombosis prevention by pneumatic compression after total hip arthroplasty. Fifty patients were randomized into one of two groups (one with pneumatic compression [n=25] and one without [n=25]). Blood was drawn from a radial arterial line immediately preoperatively (baseline), at skin closure, and 8 hours and 22 hours after the baseline sample. Serum determinations of antigen of tissue plasminogen activator and plasminogen activator inhibitor-1 were done using enzyme-linked immunosorbent assays. These data do not support the enhancement of systemic fibrinolysis mechanism for lowering thromboembolic risk after total hip arthroplasty by pneumatic compression devices. The results of this study showed no differences that were statistically significant between the two groups. The greatest difference was observed 8 hours after surgery for the plasminogen activator inhibitor-1 marker, (28.12 with compression versus 22.07 ng/mL without); however, this result was not statistically significant. The beneficial effect of mechanical compression is more likely achieved through increased flow, local fibrinolytic effects, or both.

  9. Required Be Capsule Strength For Room Temperature Transport

    SciTech Connect

    Cook, B

    2005-03-21

    The purpose of this memo is to lay out the criteria for the Be capsule strength necessary for room temperature transport. Ultimately we will test full thickness capsules by sealing high pressures inside, but currently we are limited to both thinner capsules and alternative measures of capsule material strength.

  10. 76 FR 81013 - Pipeline Safety: Information Collection Activities

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-12-27

    ... Pipeline Safety Program Certification and Hazardous Liquid Pipeline Safety Program Certification.'' PHMSA... Liquid Pipeline Safety Program Certification. OMB Control Number: 2137-0584. Current Expiration Date:...

  11. Does magnetically assisted capsule endoscopy improve small bowel capsule endoscopy completion rate? A randomised controlled trial

    PubMed Central

    Hale, Melissa F.; Drew, Kaye; Sidhu, Reena; McAlindon, Mark E.

    2016-01-01

    Background and study aims: Delayed gastric emptying is a significant factor in incomplete small bowel capsule examinations. Gastric transit could be hastened by external magnetic control of the capsule. We studied the feasibility of this approach to improve capsule endoscopy completion rates. Patients and methods: Prospective, single-center, randomized controlled trial involving 122 patients attending for small bowel capsule endoscopy using MiroCam Navi. Patients were randomized to either the control group (mobilisation for 30 minutes after capsule ingestion, followed by intramuscular metoclopramide 10 mg if the capsule failed to enter the small bowel) or the intervention group (1000 mL of water prior to capsule ingestion, followed by positional change and magnetic steering). Outcome measures were capsule endoscopy completion rate, gastric clarity and distention, relationship of body habitus to capsule endoscopy completion rate (CECR), and patient comfort scores. Results: 122 patients were recruited (61 each to the control and intervention groups: mean age 49 years [range 21 – 85], 61 females). There was no significant difference in CECR between the two groups (P = 0.39). Time to first pyloric image was significantly shorter in the intervention group (P = 0.03) but there was no difference in gastric transit times (P = 0.12), suggesting that magnetic control hastens capsular transit to the gastric antrum but does not influence duodenal passage. Gastric clarity and distention were significantly better in the intervention group (P < 0.0001 and P < 0.0001 respectively). Conclusions: Magnetic steering of a small bowel capsule is unable to overcome pyloric contractions to enhance gastric emptying and improve capsule endoscope completion rate. Excellent mucosal visualisation within the gastric cavity suggests this technique could be harnessed for capsule examination of the stomach. PMID:26878053

  12. 75 FR 5244 - Pipeline Safety: Integrity Management Program for Gas Distribution Pipelines; Correction

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-02-02

    ... implement integrity management programs. In addition to a minor correction in terminology, this document...: Integrity Management Program for Gas Distribution Pipelines; Correction AGENCY: Pipeline and...

  13. Formulation of a minimum variance deconvolution technique for compensation of pneumatic distortion in pressure sensing devices

    NASA Technical Reports Server (NTRS)

    Whitmore, Stephen A.

    1990-01-01

    Increasingly, aircraft system designs require that aerodynamic parameters derived from pneumatic measurements be employed as control-system feedbacks. Such high frequency pressure measurements' accuracy is compromised by pressure distortion due to frictional attenuation and pneumatic resonance within the sensing system. A pneumatic distortion model is here formulated and reduced to a low-order state-variable model which retains most of the full model's dynamic characteristics. This reduced-order model is coupled with standard results from minimum variance estimation theory to develop an algorithm to compensate for pneumatic-distortion effects.

  14. Clinical Effect of Endoscopic Pneumatic Dilation for Achalasia.

    PubMed

    Cheng, Peng; Shi, Hai; Zhang, Yanjie; Zhou, Huabang; Dong, Jinhua; Cai, Yiting; Hu, Xing; Dai, Qiang; Yang, Wenyan

    2015-07-01

    Although pneumatic dilation is an accepted method for the treatment of achalasia, this therapy has high recurrence and complication rates, and prolonged follow-up studies on the parameters associated with various outcomes are rare. In this prospective 10-year follow-up study, a satisfactory therapeutic effect was achieved without serious complications. We report the therapeutic experience with pneumatic dilation, having aimed to evaluate the long-term clinical safety and efficacy of pneumatic dilation. In total, 35 consecutive patients with idiopathic achalasia who underwent pneumatic dilation were followed up at regular intervals in person or by a phone interview over a 10-year period. The mean duration of the follow-up was 43.03 ± 26.34 months (range 6-120 months). Remission was assessed by the dysphagia classification and symptom scores. Patients' clinical symptom scores were calculated before and at 6 to 36  months, 37 to 60  months, and >60  months after therapy. The influence of the patients' age, gender, and disease duration on the therapeutic effect was analyzed. The success rate of the operation was 97.2% (35/36), without massive hemorrhaging, perforation or other serious complications. Dysphagia after the therapy was significantly eased (P < 0.01). In total, 35 patients have been followed up for 6 to 36  months after therapy, 21 cases for 37 to 60  months, and 5 cases for >60  months, and the patients' symptom scores separately decreased significantly compared with the pretherapy scores (P < 0.01). For these patients, the 6 to 36  months remission rate was 85.7% (30/35), the 37 to 60  months rate was 61.9% (13/21), and the >60  months rate was 40% (2/5). The dilation effect had no relationship to the patient's age, gender, and disease duration (P > 0.05). The patients in 30 cases (85.7%) were successfully treated with a single dilation, in 4 cases (11.4%) with 2 dilations, and in 1 case (2.9%) with 3 dilations. These

  15. [Is pneumatic sample transport system also a carrier for microorganisms?].

    PubMed

    Alpat, Saygin Nayman; Ozgüneş, Ilhan; Aybey, Aşkin Derya; Ertem, Osman Turgut; Akşit, Filiz

    2009-07-01

    The purpose of this study was to evaluate the possible infection and contamination risk of the pneumatic system used in our hospital and to establish essential infection control measures. The study was conducted in a quaternary health care center with 1.000 bed capacity. A total of 614 specimens were taken 2 times weekly from the pneumatic transport system and its carriers at 22 wards, 5 intensive care units, 3 laboratories, 2 blood taking units, and pharmacy. Samples were also obtained from the fingertips of 33 subjects using the system, before and after contact with the carriers. A questionnaire that consisted of 8 questions was applied to 224 subjects who worked in those units, evaluating the degree of compliance to the obligations for the cleaning of the pneumatic system and carriers and their approach in case of visible pollution at the system. Bacterial growth was observed in 15.2% (45/296) of samples in the 1st week and 7.6% (18/238) of the samples in the 2nd week, making a total of 11.8% (63/534) bacterial growth. No growth was detected from the areas where the carriers were placed. Of these 69.8% were coagulase negative staphylococci, 11.1% diphteroids, 7.9% Acinetobacter Iwoffii, 4.8% Staphylococcus aureus, 4.8% Bacillus spp. and 1.6% Enterococcus durans. Acinetobacter baumannii and Aspergillus were detected at two fingertip samples taken before the contact with carriers, while again A. baumannii and Enterobacter cloacae were detected at the samples following contact. Moreover, 31.3% of the subjects noted that they cleaned the carriers only if any visible contamination was present. In addition, 14.3% reported that they have encountered broken or spilled up material in the system for more than 5 times, 10.3% reported that they followed the instructions in case of presence of infected material inside the carriers, 23.7% reported that they always washed their hands after any contact with the carriers, 9.8% noted that they always used gloves during contact

  16. Clinical Effect of Endoscopic Pneumatic Dilation for Achalasia

    PubMed Central

    Cheng, Peng; Shi, Hai; Zhang, Yanjie; Zhou, Huabang; Dong, Jinhua; Cai, Yiting; Hu, Xing; Dai, Qiang; Yang, Wenyan

    2015-01-01

    Abstract Although pneumatic dilation is an accepted method for the treatment of achalasia, this therapy has high recurrence and complication rates, and prolonged follow-up studies on the parameters associated with various outcomes are rare. In this prospective 10-year follow-up study, a satisfactory therapeutic effect was achieved without serious complications. We report the therapeutic experience with pneumatic dilation, having aimed to evaluate the long-term clinical safety and efficacy of pneumatic dilation. In total, 35 consecutive patients with idiopathic achalasia who underwent pneumatic dilation were followed up at regular intervals in person or by a phone interview over a 10-year period. The mean duration of the follow-up was 43.03 ± 26.34 months (range 6–120 months). Remission was assessed by the dysphagia classification and symptom scores. Patients’ clinical symptom scores were calculated before and at 6 to 36 months, 37 to 60 months, and >60 months after therapy. The influence of the patients’ age, gender, and disease duration on the therapeutic effect was analyzed. The success rate of the operation was 97.2% (35/36), without massive hemorrhaging, perforation or other serious complications. Dysphagia after the therapy was significantly eased (P < 0.01). In total, 35 patients have been followed up for 6 to 36 months after therapy, 21 cases for 37 to 60 months, and 5 cases for >60 months, and the patients’ symptom scores separately decreased significantly compared with the pretherapy scores (P < 0.01). For these patients, the 6 to 36 months remission rate was 85.7% (30/35), the 37 to 60 months rate was 61.9% (13/21), and the >60 months rate was 40% (2/5). The dilation effect had no relationship to the patient's age, gender, and disease duration (P > 0.05). The patients in 30 cases (85.7%) were successfully treated with a single dilation, in 4 cases (11.4%) with 2 dilations, and in 1 case (2.9%) with 3 dilations

  17. Towards Polymer-Based Capsules with Drastically Reduced Controlled Permeability

    NASA Astrophysics Data System (ADS)

    Andreeva, Daria V.; Sukhorukov, Gleb B.

    Small molecules (dyes, therapeutics, etc.) could be easily handled, stored, delivered, and released by polyelectrolyte capsules. To make the polyelectrolyte capsule more efficient for small molecule encapsulation, capsule permeability should be significantly decreased. Here, we demonstrate the possibility to entrap water-soluble molecular species into polyelectrolyte capsules modified by a low permeable dense polymer (polypyrrole). Possible future areas in PE capsule application as carriers for gases and volatiles in the pharmaceutical, food, and gases industry, agriculture and cosmetology are discussed.

  18. Dynamics of nonspherical compound capsules in simple shear flow

    NASA Astrophysics Data System (ADS)

    Luo, Zheng Yuan; Bai, Bo Feng

    2016-10-01

    The dynamics of an initially ellipsoidal compound capsule in a simple shear flow is investigated numerically using a three-dimensional front-tracking finite-difference model. Membrane bending resistance is included based on Helfrich's energy function besides the resistances against shear deformation and area dilatation governed by the constitutive law of Skalak et al. In this paper, we focus specifically on how the presence of a spherical inner capsule and its size affects the characteristics and transition of various dynamical states of nonspherical compound capsules (i.e., the outer capsule). Significant differences in the dynamical characteristics are observed between compound capsules and homogeneous capsules in both qualitative and quantitative terms. We find the transition from swinging to tumbling can occur at vanishing viscosity mismatch through increasing the inner capsule size alone to a critical value regardless of the initial shape of the nonspherical compound capsule (i.e., prolate or oblate). Besides, for compound capsules with viscosity mismatch, the critical viscosity ratio for the swinging-to-tumbling transition remarkably decreases by increasing the inner capsule size. It is thus concluded that the inner capsule size is a key governing parameter of compound capsule dynamics apart from the capillary number, aspect ratio, and viscosity ratio that have been long identified for homogeneous capsules. Further, we discuss the mechanisms underlying the effects of the inner capsule on the compound capsule dynamics from the viewpoint of the effective viscosity of internal fluid and find that the effects of the inner capsule on compound capsule dynamics are qualitatively similar to that of increasing the internal viscosity on homogeneous capsule dynamics. However, in quantitative terms, the compound capsule cannot be viewed as a homogeneous capsule with higher viscosity as obvious inhomogeneity in fluid stress distribution is induced by the inner membrane.

  19. Capsule Depolymerase Overexpression Reduces Bacillus anthracis Virulence

    DTIC Science & Technology

    2010-01-01

    Friedlander, A. M. (2004). The NheA component of the non- hemolytic enterotoxin of Bacillus cereus is produced by Bacillus anthracis but is not required for...Capsule depolymerase overexpression reduces Bacillus anthracis virulence Angelo Scorpio,3 Donald J. Chabot, William A. Day,4 Timothy A. Hoover and...depolymerase (CapD) is a c-glutamyl transpeptidase and a product of the Bacillus anthracis capsule biosynthesis operon. In this study, we examined the

  20. Capsule Implosion Symmetry in OMEGA Tetrahedral Hohlraums

    NASA Astrophysics Data System (ADS)

    Schnittman, J. D.; Craxton, R. S.; Pollaine, S. M.; Turner, R. E.; Wallace, J. M.; Murphy, T. J.; Delamater, N. D.; Oertel, J. A.; Hauer, A. A.; Klare, K. A.

    1998-11-01

    The 3-D time-dependent capsule implosion symmetry has been calculated for spherical hohlraums with four laser entrance holes. The code BUTTERCUP calculates the locations of beam spots on the hohlraum wall and includes a model for the absorption and x-ray conversion of the laser energy. The gold wall is heated by 1-D radiation diffusion, and radiation transport is carried out with a 3-D view-factor algorithm. A simple hydrodynamic calculation of the imploding capsule gives the resulting 3-D time-dependent drive symmetry. The predicted radiation uniformity incident on the capsule is very good ( ~1% rms) throughout the laser pulse. Experimental images of the capsule show round implosions with convergence ratios of 10 for standard capsules,(T. J. Murphy, Bull. Am. Phys. Soc. 42), 2008 (1997). in agreement with predictions. Radiation temperatures and capsule trajectories are calculated and show good agreement with experiment. This work was supported by the U.S. Department of Energy Office of Inertial Confinement Fusion under Cooperative Agreement No. DE-FC03-92SF19460.

  1. Light weight escape capsule for fighter aircraft

    NASA Technical Reports Server (NTRS)

    Robert, James A.

    1988-01-01

    Emergency crew escape capabilities have been less than adequate for fighter aircraft since before WW II. From the over-the-side bailout of those days through the current ejection seat with a rocket catapult, escaping from a disabled aircraft has been risky at best. Current efforts are underway toward developing a high-tech, smart ejection seat that will give fighter pilots more room to live in the sky, but an escape capsule is needed to meet current and future fighter envelopes. Escape capsules have a bad reputation due to past examples of high weight, poor performance and great complexity. However, the advantages available demand that a capsule be developed. This capsule concept will minimize the inherent disavantages and incorporate the benefits while integrating all aspects of crew station design. The resulting design is appropriate for a crew station of the year 2010 and includes improved combat acceleration protection, chemical or biological combat capability, improved aircraft to escape system interaction, and the highest level of escape performance achievable. The capsule is compact, which can allow a reduced aircraft size and weighs only 1200 lb. The escape system weight penalty is only 120 lb higher than that for the next ejection seat and the capsule has a corresponding increase in performance.

  2. Pipeline accident effects for hazardous liquid pipelines. Final report

    SciTech Connect

    Greenfeld, J.; Golub, E.; Dresnack, R.; Griffis, F.H.; Pignataro, L.J.

    1996-08-01

    The project team identified the factors that cause pipeline failures and the factors that effect accidents on hazardous liquid pipelines. Since the normalizing of the data was not possible, the authors of this report used indirect and inferential approaches in the analysis. The databases used for this analysis are LIQUID (accident data for 1968-1985) and LIQLCK (accident data for 1985-present). The main finding of this complete data on hazardous liquid accidents should be collected. Other conclusions are that prevention programs should be more effective, and pipe components such as valves, O-rings, gaskets and nipples are a significant source of potentially reducible accidents.

  3. 76 FR 50539 - Pipeline Safety: Information Collection Activities

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-08-15

    ... TRANSPORTATION Pipeline and Hazardous Materials Safety Administration Pipeline Safety: Information Collection Activities AGENCY: Pipeline and Hazardous Materials Safety Administration (PHMSA), DOT. ACTION: Notice and... collection under Office of Management and Budget (OMB) Control No. 2137-0622, titled ``Pipeline...

  4. 75 FR 40863 - Pipeline Safety: Information Collection Activities

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-07-14

    ... Pipeline and Hazardous Materials Safety Administration Pipeline Safety: Information Collection Activities AGENCY: Pipeline and Hazardous Materials Safety Administration (PHMSA), DOT. ACTION: Notice and request... Transportation, Pipeline and Hazardous Materials Safety Administration, 1200 New Jersey Avenue, SE.,...

  5. 77 FR 74275 - Pipeline Safety: Information Collection Activities

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-12-13

    ... Pipeline and Hazardous Materials Safety Administration Pipeline Safety: Information Collection Activities AGENCY: Pipeline and Hazardous Materials Safety Administration (PHMSA), DOT. ACTION: Notice and request..., DC 20590-0001. SUPPLEMENTARY INFORMATION: Title: Pipeline Safety: Control Room...

  6. 76 FR 45904 - Pipeline Safety: Information Collection Activities

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-08-01

    ... Pipeline and Hazardous Materials Safety Administration Pipeline Safety: Information Collection Activities AGENCY: Pipeline and Hazardous Materials Safety Administration (PHMSA), DOT. ACTION: Notice and request... by mail at U.S. Department of Transportation, Pipeline and Hazardous Materials Safety...

  7. 76 FR 65778 - Pipeline Safety: Information Collection Activities

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-10-24

    ... Pipeline and Hazardous Materials Safety Administration Pipeline Safety: Information Collection Activities AGENCY: Pipeline and Hazardous Materials Safety Administration (PHMSA), DOT. ACTION: Notice and request... to discontinue the following information collection: Title: Pipeline Safety: Excess Flow...

  8. 75 FR 76077 - Pipeline Safety: Information Collection Activities

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-12-07

    ... Pipeline and Hazardous Materials Safety Administration Pipeline Safety: Information Collection Activities AGENCY: Pipeline and Hazardous Materials Safety Administration (PHMSA), DOT. ACTION: Notice and request..., titled ``Pipeline Safety: Periodic Underwater Inspection.'' PHMSA is preparing to request approval...

  9. 75 FR 77694 - Pipeline Safety: Information Collection Activities

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-12-13

    ... Pipeline and Hazardous Materials Safety Administration Pipeline Safety: Information Collection Activities AGENCY: Pipeline and Hazardous Materials Safety Administration, DOT. ACTION: Notice and request for... information collection for the National Pipeline Registry. PHMSA is preparing to request Office of...

  10. 75 FR 30099 - Pipeline Safety: Information Collection Activities

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-05-28

    ... TRANSPORTATION Pipeline and Hazardous Materials Safety Administration Pipeline Safety: Information Collection Activities AGENCY: Pipeline and Hazardous Materials Safety Administration, DOT. ACTION: Notice. SUMMARY: In... Collection Request titled: ``Pipeline Safety: New Reporting Requirements for Hazardous Liquid...

  11. 75 FR 4136 - Pipeline Safety: Request To Modify Special Permit

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-01-26

    ... Pipeline and Hazardous Materials Safety Administration Pipeline Safety: Request To Modify Special Permit AGENCY: Pipeline and Hazardous Materials Safety Administration (PHMSA); DOT. ACTION: Notice; Reopening of..., which concerns the external coating on its gas pipeline. DATES: Submit any comments regarding...

  12. 77 FR 15453 - Pipeline Safety: Information Collection Activities

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-03-15

    ... Pipeline and Hazardous Materials Safety Administration Pipeline Safety: Information Collection Activities AGENCY: Pipeline and Hazardous Materials Safety Administration (PHMSA), DOT. ACTION: Notice and request... regards the renewal of an information collection titled, ``Gas Pipeline Safety Program Certification...

  13. 78 FR 57455 - Pipeline Safety: Information Collection Activities

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-09-18

    ... Pipeline and Hazardous Materials Safety Administration Pipeline Safety: Information Collection Activities AGENCY: Pipeline and Hazardous Materials Safety Administration (PHMSA), DOT. ACTION: Notice and request... of Transportation, Pipeline and Hazardous Materials Safety Administration, 1200 New Jersey Avenue...

  14. 75 FR 67450 - Pipeline Safety: Control Room Management Implementation Workshop

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-11-02

    ... Pipeline and Hazardous Materials Safety Administration Pipeline Safety: Control Room Management... of Pipeline Safety Representatives (NAPSR) on the implementation of pipeline control room management. The workshop is intended to foster an understanding of the Control Room Management Rule issued...

  15. 76 FR 6603 - Certain New Pneumatic Off-the-Road Tires From the People's Republic of China: Notice of Extension...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-02-07

    ... pneumatic off-the-road tires (``OTR tires'') from the People's Republic of China (``PRC'') for the period... on OTR tires from the PRC. See Certain New Pneumatic Off-the-Road Tires From the People's Republic...

  16. Method and system for pipeline communication

    DOEpatents

    Richardson; John G.

    2008-01-29

    A pipeline communication system and method includes a pipeline having a surface extending along at least a portion of the length of the pipeline. A conductive bus is formed to and extends along a portion of the surface of the pipeline. The conductive bus includes a first conductive trace and a second conductive trace with the first and second conductive traces being adapted to conformally couple with a pipeline at the surface extending along at least a portion of the length of the pipeline. A transmitter for sending information along the conductive bus on the pipeline is coupled thereto and a receiver for receiving the information from the conductive bus on the pipeline is also couple to the conductive bus.

  17. Northern Border Pipeline Company NPDES Permit

    EPA Pesticide Factsheets

    Under NPDES permit MT-0030791, the Northern Border Pipeline Company is authorized to discharge from locations along the Northern Border Gas Transmission Pipeline located within the exterior boundaries of the Fort Peck Indian Reservation, Montana.

  18. 76 FR 44985 - Pipeline Safety: Potential for Damage to Pipeline Facilities Caused by Flooding

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-07-27

    ...] [FR Doc No: 2011-19029] DEPARTMENT OF TRANSPORTATION Pipeline and Hazardous Materials Safety Administration [Docket No. PHMSA-2011-0177] Pipeline Safety: Potential for Damage to Pipeline Facilities Caused by Flooding AGENCY: Pipeline and Hazardous Materials Safety Administration (PHMSA), DOT....

  19. 76 FR 303 - Pipeline Safety: Safety of On-Shore Hazardous Liquid Pipelines

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-01-04

    ...: Safety of On-Shore Hazardous Liquid Pipelines AGENCY: Pipeline and Hazardous Materials Safety... Rulemaking (ANPRM) titled: ``Safety of On-Shore Hazardous Liquid Pipelines'' seeking comments on the need for changes to the regulations covering hazardous liquid onshore pipelines. PHMSA has received requests...

  20. Capsule endoscopy in neoplastic diseases.

    PubMed

    Pennazio, Marco; Rondonotti, Emanuele; de Franchis, Roberto

    2008-09-14

    Until recently, diagnosis and management of small-bowel tumors were delayed by the difficulty of access to the small bowel and the poor diagnostic capabilities of the available diagnostic techniques. An array of new methods has recently been developed, increasing the possibility of detecting these tumors at an earlier stage. Capsule endoscopy (CE) appears to be an ideal tool to recognize the presence of neoplastic lesions along this organ, since it is non-invasive and enables the entire small bowel to be visualized. High-quality images of the small-bowel mucosa may be captured and small and flat lesions recognized, without exposure to radiation. Recent studies on a large population of patients undergoing CE have reported small-bowel tumor frequency only slightly above that reported in previous surgical series (range, 1.6%-2.4%) and have also confirmed that the main clinical indication to CE in patients with small-bowel tumors is obscure gastrointestinal (GI) bleeding. The majority of tumors identified by CE are malignant; many were unsuspected and not found by other methods. However, it remains difficult to identify pathology and tumor type based on the lesion's endoscopic appearance. Despite its limitations, CE provides crucial information leading in most cases to changes in subsequent patient management. Whether the use of CE in combination with other new diagnostic (MRI or multidetector CT enterography) and therapeutic (Push-and-pull enteroscopy) techniques will lead to earlier diagnosis and treatment of these neoplasms, ultimately resulting in a survival advantage and in cost savings, remains to be determined through carefully-designed studies.

  1. California Natural Gas Pipelines: A Brief Guide

    SciTech Connect

    Neuscamman, Stephanie; Price, Don; Pezzola, Genny; Glascoe, Lee

    2013-01-22

    The purpose of this document is to familiarize the reader with the general configuration and operation of the natural gas pipelines in California and to discuss potential LLNL contributions that would support the Partnership for the 21st Century collaboration. First, pipeline infrastructure will be reviewed. Then, recent pipeline events will be examined. Selected current pipeline industry research will be summarized. Finally, industry acronyms are listed for reference.

  2. 14 CFR 23.1416 - Pneumatic de-icer boot system.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... intended function under any normal system operating temperature or pressure, and (c) Means to indicate to... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Pneumatic de-icer boot system. 23.1416... Safety Equipment § 23.1416 Pneumatic de-icer boot system. If certification with ice protection...

  3. 46 CFR 108.409 - Location and spacing of tubing in pneumatic fire detection system.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... detection system. 108.409 Section 108.409 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS DESIGN AND EQUIPMENT Fire Extinguishing Systems § 108.409 Location and spacing of tubing in pneumatic fire detection system. (a) All tubing in a pneumatic fire...

  4. His majesty's subjects: from laboratory to human experiment in pneumatic chemistry.

    PubMed

    Stewart, Larry

    2009-09-20

    Experiments in pneumatic chemistry paved the way for medical innovation in the last quarter of the eighteenth century. Thomas Beddoes and James Watt were instrumental in the spread of the use of new gas chemistry in pneumatic therapy, but they were far from alone. There was no shortage of experimental subjects, as the practice was quickly taken up by medics throughout Britain.

  5. A quantitative method for the evaluation of three-dimensional structure of temporal bone pneumatization

    PubMed Central

    Hill, Cheryl A.; Richtsmeier, Joan T.

    2010-01-01

    Temporal bone pneumatization has been included in lists of characters used in phylogenetic analyses of human evolution. While studies suggest that the extent of pneumatization has decreased over the course of human evolution, little is known about the processes underlying these changes or their significance. In short, reasons for the observed reduction and the potential reorganization within pneumatized spaces are unknown. Technological limitations have limited previous analyses of pneumatization in extant and fossil species to qualitative observations of the extent of temporal bone pneumatization. In this paper, we introduce a novel application of quantitative methods developed for the study of trabecular bone to the analysis of pneumatized spaces of the temporal bone. This method utilizes high-resolution X-ray computed tomography (HRXCT) images and quantitative software to estimate three-dimensional parameters (bone volume fractions, anisotropy, and trabecular thickness) of bone structure within defined units of pneumatized spaces. We apply this approach in an analysis of temporal bones of diverse but related primate species, Gorilla gorilla, Pan troglodytes, Homo sapiens, and Papio hamadryas anubis, to illustrate the potential of these methods. In demonstrating the utility of these methods, we show that there are interspecific differences in the bone structure of pneumatized spaces, perhaps reflecting changes in the localized growth dynamics, location of muscle attachments, encephalization, or basicranial flexion. PMID:18715622

  6. 46 CFR 128.240 - Hydraulic or pneumatic power and control-materials and pressure design.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 4 2011-10-01 2011-10-01 false Hydraulic or pneumatic power and control-materials and...) OFFSHORE SUPPLY VESSELS MARINE ENGINEERING: EQUIPMENT AND SYSTEMS Materials and Pressure Design § 128.240 Hydraulic or pneumatic power and control—materials and pressure design. (a) Each standard piping...

  7. 49 CFR 571.117 - Standard No. 117; Retreaded pneumatic tires.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... HIGHWAY TRAFFIC SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION FEDERAL MOTOR VEHICLE SAFETY STANDARDS Federal Motor Vehicle Safety Standards § 571.117 Standard No. 117; Retreaded pneumatic tires. S1. Scope... passenger car tires. S2. Purpose. The purpose of this standard is to require retreaded pneumatic...

  8. 21 CFR 874.4250 - Ear, nose, and throat electric or pneumatic surgical drill.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Ear, nose, and throat electric or pneumatic... AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES EAR, NOSE, AND THROAT DEVICES Surgical Devices § 874.4250 Ear, nose, and throat electric or pneumatic surgical drill. (a) Identification. An ear, nose,...

  9. 21 CFR 874.4250 - Ear, nose, and throat electric or pneumatic surgical drill.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Ear, nose, and throat electric or pneumatic... AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES EAR, NOSE, AND THROAT DEVICES Surgical Devices § 874.4250 Ear, nose, and throat electric or pneumatic surgical drill. (a) Identification. An ear, nose,...

  10. 21 CFR 874.4250 - Ear, nose, and throat electric or pneumatic surgical drill.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Ear, nose, and throat electric or pneumatic... AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES EAR, NOSE, AND THROAT DEVICES Surgical Devices § 874.4250 Ear, nose, and throat electric or pneumatic surgical drill. (a) Identification. An ear, nose,...

  11. 49 CFR 571.129 - Standard No. 129; New non-pneumatic tires for passenger cars.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... passenger cars. 571.129 Section 571.129 Transportation Other Regulations Relating to Transportation...-pneumatic tires for passenger cars. S1Scope. This standard specifies tire dimensions and laboratory test... applies to new temporary spare non-pneumatic tires for use on passenger cars. S3Definitions. Carcass...

  12. 49 CFR 571.129 - Standard No. 129; New non-pneumatic tires for passenger cars.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... passenger cars. 571.129 Section 571.129 Transportation Other Regulations Relating to Transportation...-pneumatic tires for passenger cars. S1Scope. This standard specifies tire dimensions and laboratory test... applies to new temporary spare non-pneumatic tires for use on passenger cars. S3Definitions. Carcass...

  13. 49 CFR 571.129 - Standard No. 129; New non-pneumatic tires for passenger cars.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... passenger cars. 571.129 Section 571.129 Transportation Other Regulations Relating to Transportation...-pneumatic tires for passenger cars. S1Scope. This standard specifies tire dimensions and laboratory test... applies to new temporary spare non-pneumatic tires for use on passenger cars. S3Definitions. Carcass...

  14. 49 CFR 571.129 - Standard No. 129; New non-pneumatic tires for passenger cars.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... passenger cars. 571.129 Section 571.129 Transportation Other Regulations Relating to Transportation...-pneumatic tires for passenger cars. S1Scope. This standard specifies tire dimensions and laboratory test... applies to new temporary spare non-pneumatic tires for use on passenger cars. S3Definitions. Carcass...

  15. 40 CFR 60.253 - Standards for pneumatic coal-cleaning equipment.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 7 2014-07-01 2014-07-01 false Standards for pneumatic coal-cleaning... PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Coal Preparation and Processing Plants § 60.253 Standards for pneumatic coal-cleaning equipment. (a) On and...

  16. 40 CFR 60.253 - Standards for pneumatic coal-cleaning equipment.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 6 2011-07-01 2011-07-01 false Standards for pneumatic coal-cleaning... PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Coal Preparation and Processing Plants § 60.253 Standards for pneumatic coal-cleaning equipment. (a) On and...

  17. 40 CFR 60.253 - Standards for pneumatic coal-cleaning equipment.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 7 2013-07-01 2013-07-01 false Standards for pneumatic coal-cleaning... PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Coal Preparation and Processing Plants § 60.253 Standards for pneumatic coal-cleaning equipment. (a) On and...

  18. 40 CFR 60.253 - Standards for pneumatic coal-cleaning equipment.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 7 2012-07-01 2012-07-01 false Standards for pneumatic coal-cleaning... PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Coal Preparation and Processing Plants § 60.253 Standards for pneumatic coal-cleaning equipment. (a) On and...

  19. 40 CFR 60.253 - Standards for pneumatic coal-cleaning equipment.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 6 2010-07-01 2010-07-01 false Standards for pneumatic coal-cleaning... PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Coal Preparation and Processing Plants § 60.253 Standards for pneumatic coal-cleaning equipment. (a) On and...

  20. 30 CFR 250.1005 - Inspection requirements for DOI pipelines.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 2 2011-07-01 2011-07-01 false Inspection requirements for DOI pipelines. 250... Pipelines and Pipeline Rights-of-Way § 250.1005 Inspection requirements for DOI pipelines. (a) Pipeline... indication of pipeline leakage. The results of these inspections shall be retained for at least 2 years...

  1. Muscle- and pneumatic-powered counterpulsating LVADs: a pilot study.

    PubMed

    Wilde, J C; van Loon, J; Bishop, N D; Shelton, A D; Marten, C; Kolff, W J; Stephenson, L; Baciewicz, F; Nakajima, H; Thomas, G

    1994-03-01

    There is a worldwide interest in supporting the failing heart with a skeletal muscle by either wrapping it around the natural heart (dynamic cardiomyoplasty) or by constructing a skeletal muscle ventricle (SMV) used for counterpulsation. Conventional cardiomyoplasty in many clinics carries an operative mortality rate of 15-20% partly because it requires 6 weeks to train the muscle to contract continually. A flexible, pear-shaped blood pump with an inflatable air chamber was designed and made around which a muscle can be wrapped. The advantage of our design is that it can also be driven by pneumatic power, immediately supporting the circulation of a seriously ill patient while that patient is still on the operating table. After a period of time to allow for revascularization and the subsequent training of the muscle, the external pneumatic power can be gradually discontinued. Then the assisted patient becomes tether-free. If, at any time, the muscle power fails, the pneumatic-powered mechanism can be reactivated. In the preferred approach, the blood pump is connected to the aorta for diastolic counterpulsation. A muscle can either be wrapped around the blood pump directly, or around one of two separate muscle pouches connected to the blood pump. To facilitate surgery, a large pouch is inserted under the musculus latissimus dorsi, which is connected to a blood pump. When stimulated, the muscle will contract over the pouch compressing it and providing power to the blood pump. If it is found that the pressure generated in the pouch cannot meet the aortic blood pressure, it can be augmented by using a pressure amplifier.(ABSTRACT TRUNCATED AT 250 WORDS)

  2. [Pneumatic dilatation of achalasia: local experience in treating 41 patients].

    PubMed

    Honein, Khalil; Slim, Rita; Yaghi, César; Kheir, Bahaa; Bou Jaoudé, Joseph; Sayegh, Raymond

    2007-01-01

    L'achalasia is the best known primary motor disorder of the esophagus in which the lower esophageal sphincter (LES) has abnormally high resting pressure and incomplete relaxation with swallowing. Pneumatic dilatation (PD) remains the first choice of treatment. Our aim was to report, in a retrospective way, our experience in treating with pneumatic dilatation 41 achalasia patients admitted to the gastroenterology unit at Hôtel-Dieu de France (HDF) hospital between 1994 and 2004. A total of 46 dilatations were performed in 41 patients with achalasia [20 males and 21 females, the mean age was 46.8 years (range, 15-90)]. All patients underwent an initial dilatation by inflating a 35 mm balloon to 7 psi three times successively under fluoroscopic control. The need for subsequent dilatation with the same technique or for surgical treatment was based on symptom assessment. The mean follow-up period was 36.7 months (3 mo-7 years). Among the patients whose follow-up information was available, a satisfactory result was achieved in 29 patients (80.5%) after only one or two sessions of pneumatic dilatation. Esophageal perforation as a short-term complication was observed in one patient (2.17%). Seven patients were referred for surgery (one for esophageal perforation and six for persistent or recurrent symptoms). In conclusion, performing balloon dilatation under fluoroscopic observation is simple, safe and efficacious for treating patients with achalasia. Referral to repeated PD or to surgical myotomy should be discussed in case of no response to a first session of PD.

  3. 77 FR 6536 - Certain New Pneumatic Off-the-Road Tires From the People's Republic of China: Notice of Extension...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-02-08

    ... International Trade Administration Certain New Pneumatic Off-the-Road Tires From the People's Republic of China... administrative review of the antidumping duty order on certain new pneumatic off-the-road tires (``off-the-road... administrative review of the antidumping order on off- the-road tires from the PRC. See Certain New Pneumatic...

  4. 75 FR 49459 - Certain New Pneumatic Off-The-Road Tires from the People's Republic of China: Notice of Amended...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-08-13

    ... International Trade Administration A-570-912 Certain New Pneumatic Off-The-Road Tires from the People's Republic... determination in the antidumping investigation on certain new pneumatic off-the-road tires (``OTR tires'') from.... See Certain New Pneumatic Off-The-Road-Tires from the People's Republic of China: Final...

  5. 75 FR 31422 - Certain New Pneumatic Off-The-Road Tires from the People's Republic of China: Notice of Decision...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-06-03

    ... International Trade Administration A-570-912 Certain New Pneumatic Off-The-Road Tires from the People's Republic... antidumping investigation on certain new pneumatic off-the-road tires (``OTR tires'') from the People's... Pneumatic Off-The-Road-Tires from the People's Republic of China: Final Affirmative Determination of...

  6. 75 FR 24884 - Certain New Pneumatic Off-the-Road Tires from the People's Republic of China: Partial Rescission...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-05-06

    ...., Tianjin Wanda Tyre Co., Ltd., and Triangle Tyre Co., Ltd. See Certain New Pneumatic Off-the-Road Tires... International Trade Administration Certain New Pneumatic Off-the-Road Tires from the People's Republic of China... Pneumatic Off-the-Road Tires (OTR Tires) from the People's Republic of China (PRC) for the period...

  7. Pipeline Safety and Security: Federal Programs

    DTIC Science & Technology

    2010-02-18

    and Hazardous Material Safety Administration (§304). The Pipeline and Hazardous Materials Safety Administration ( PHMSA ), within the Department of...Transportation (DOT), is the lead federal regulator of pipeline safety. PHMSA uses a variety of strategies to promote compliance with its safety...relations; and monitoring compliance with security standards, requirements, and regulation. While PHMSA and TSA have distinct missions, pipeline safety

  8. Recession curbs gas pipeline construction costs

    SciTech Connect

    Morgan, J.M.

    1983-01-24

    This paper shows how after 5 yrs. of inflation, gas pipeline construction costs have finally felt the effects of a severe building recession. First quarter (1982) construction activity, compressor equipment and drive units, and high-pressure gas-station piping are discussed. Graphs of OGJ-Morgan composite gas pipeline cost, and gas pipeline cost component indexes are presented.

  9. 27 CFR 19.274 - Pipelines.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 1 2010-04-01 2010-04-01 false Pipelines. 19.274 Section... THE TREASURY LIQUORS DISTILLED SPIRITS PLANTS Construction, Equipment and Security § 19.274 Pipelines. (a) General. (1) Pipelines for the conveyance of spirits, denatured spirits, articles, or wines...

  10. 49 CFR 195.210 - Pipeline location.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 3 2011-10-01 2011-10-01 false Pipeline location. 195.210 Section 195.210 Transportation Other Regulations Relating to Transportation (Continued) PIPELINE AND HAZARDOUS MATERIALS SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) PIPELINE SAFETY TRANSPORTATION OF HAZARDOUS LIQUIDS...

  11. 49 CFR 195.210 - Pipeline location.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 3 2013-10-01 2013-10-01 false Pipeline location. 195.210 Section 195.210 Transportation Other Regulations Relating to Transportation (Continued) PIPELINE AND HAZARDOUS MATERIALS SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) PIPELINE SAFETY TRANSPORTATION OF HAZARDOUS LIQUIDS...

  12. 49 CFR 195.210 - Pipeline location.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 3 2012-10-01 2012-10-01 false Pipeline location. 195.210 Section 195.210 Transportation Other Regulations Relating to Transportation (Continued) PIPELINE AND HAZARDOUS MATERIALS SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) PIPELINE SAFETY TRANSPORTATION OF HAZARDOUS LIQUIDS...

  13. 49 CFR 195.422 - Pipeline repairs.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 3 2011-10-01 2011-10-01 false Pipeline repairs. 195.422 Section 195.422 Transportation Other Regulations Relating to Transportation (Continued) PIPELINE AND HAZARDOUS MATERIALS SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) PIPELINE SAFETY TRANSPORTATION OF HAZARDOUS LIQUIDS...

  14. 49 CFR 195.422 - Pipeline repairs.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 3 2013-10-01 2013-10-01 false Pipeline repairs. 195.422 Section 195.422 Transportation Other Regulations Relating to Transportation (Continued) PIPELINE AND HAZARDOUS MATERIALS SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) PIPELINE SAFETY TRANSPORTATION OF HAZARDOUS LIQUIDS...

  15. 49 CFR 195.422 - Pipeline repairs.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false Pipeline repairs. 195.422 Section 195.422 Transportation Other Regulations Relating to Transportation (Continued) PIPELINE AND HAZARDOUS MATERIALS SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) PIPELINE SAFETY TRANSPORTATION OF HAZARDOUS LIQUIDS...

  16. 49 CFR 195.210 - Pipeline location.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 3 2014-10-01 2014-10-01 false Pipeline location. 195.210 Section 195.210 Transportation Other Regulations Relating to Transportation (Continued) PIPELINE AND HAZARDOUS MATERIALS SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) PIPELINE SAFETY TRANSPORTATION OF HAZARDOUS LIQUIDS...

  17. 49 CFR 195.210 - Pipeline location.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false Pipeline location. 195.210 Section 195.210 Transportation Other Regulations Relating to Transportation (Continued) PIPELINE AND HAZARDOUS MATERIALS SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) PIPELINE SAFETY TRANSPORTATION OF HAZARDOUS LIQUIDS...

  18. 27 CFR 19.587 - Pipelines.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 1 2010-04-01 2010-04-01 false Pipelines. 19.587 Section... THE TREASURY LIQUORS DISTILLED SPIRITS PLANTS Containers and Marks Containers § 19.587 Pipelines. Pursuant to the provisions of this part, pipelines which conform to the requirements of § 19.274 may...

  19. 49 CFR 195.422 - Pipeline repairs.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 3 2012-10-01 2012-10-01 false Pipeline repairs. 195.422 Section 195.422 Transportation Other Regulations Relating to Transportation (Continued) PIPELINE AND HAZARDOUS MATERIALS SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) PIPELINE SAFETY TRANSPORTATION OF HAZARDOUS LIQUIDS...

  20. 49 CFR 195.422 - Pipeline repairs.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 3 2014-10-01 2014-10-01 false Pipeline repairs. 195.422 Section 195.422 Transportation Other Regulations Relating to Transportation (Continued) PIPELINE AND HAZARDOUS MATERIALS SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) PIPELINE SAFETY TRANSPORTATION OF HAZARDOUS LIQUIDS...

  1. Note: A fast pneumatic sample-shuttle with attenuated shocks

    SciTech Connect

    Biancalana, Valerio; Dancheva, Yordanka; Stiaccini, Leonardo

    2014-03-15

    We describe a home-built pneumatic shuttle suitable for the fast displacement of samples in the vicinity of a highly sensitive atomic magnetometer. The samples are magnetized at 1 T using a Halbach assembly of magnets. The device enables the remote detection of free-induction-decay in ultra-low-field and zero-field nuclear magnetic resonance (NMR) experiments, in relaxometric measurements and in other applications involving the displacement of magnetized samples within time intervals as short as a few tens of milliseconds. Other possible applications of fast sample shuttling exist in radiological studies, where samples have to be irradiated and then analyzed in a cold environment.

  2. Compact, Non-Pneumatic Rock-Powder Samplers

    NASA Technical Reports Server (NTRS)

    Sherrit, Stewart; Bar-Cohen, Yoseph; Badescu, Mircea; Bao, Xiaoqi; Chang, Zensheu; Jones, Christopher; Aldrich, Jack

    2008-01-01

    Tool bits that automatically collect powdered rock, permafrost, or other hard material generated in repeated hammering action have been invented. The present invention pertains to the special case in which it is desired to collect samples in powder form for analysis by x-ray diffraction and possibly other techniques. The present invention eliminates the need for both the mechanical collection equipment and the crushing chamber and the pneumatic collection equipment of prior approaches, so that it becomes possible to make the overall sample-acquisition apparatus more compact.

  3. PNEUMATIC MICROVALVE FOR ELECTROKINETIC SAMPLE PRECONCENTRATION AND CAPILLARY ELECTROPHORESIS INJECTION

    SciTech Connect

    Cong, Yongzheng; Rausch, Sarah J.; Geng, Tao; Jambovane, Sachin R.; Kelly, Ryan T.

    2014-10-27

    Here we show that a closed pneumatic microvalve on a PDMS chip can serve as a semipermeable membrane under an applied potential, enabling current to pass through while blocking the passage of charged analytes. Enrichment of both anionic and cationic species has been demonstrated, and concentration factors of ~70 have been achieved in just 8 s. Once analytes are concentrated, the valve is briefly opened and the sample is hydrodynamically injected onto an integrated microchip or capillary electrophoresis (CE) column. In contrast to existing preconcentration approaches, the membrane-based method described here enables both rapid analyte concentration as well as high resolution separations.

  4. Computed tomography of temporal bone pneumatization. 1. Normal pattern and morphology

    SciTech Connect

    Virapongse, C.; Sarwar, M.; Bhimani, S.; Sasaki, C.; Shapiro, R.

    1985-09-01

    The pneumatization of 141 normal temporal bones on computed tomography (CT) was evaluated in 100 patients. Because of the controversy surrounding the sclerotic squamomastoid (mastoid), temporal bones with this finding were discarded. A CT index of pneumatization was based on the pneumatized area and the number of cells seen within a representative scanning section. Results suggest that squamomastoid pneumatization follows the classic normal distribution and does not correlate with age, gender, or laterality. A high degree of symmetry was found in 41 patients who had both ears examined. Air-cell configuration was variable. Air-cell size tended to increase progressively from the mastoid antrum. The scutum pseudotumor appearance caused by incomplete pneumatization was seen frequently, and should not be mistaken for mastoiditis or an osteoma. Thick sections producing partial-volume effect may also produce this spurious finding. Therefore, when searching for mucosal thickening due to mastoiditis, large air cells should preferably be analyzed.

  5. A scintigraphic investigation of the disintegration behaviour of capsules in fasting subjects: a comparison of hypromellose capsules containing carrageenan as a gelling agent and standard gelatin capsules.

    PubMed

    Tuleu, C; Khela, M K; Evans, D F; Jones, B E; Nagata, S; Basit, A W

    2007-03-01

    Two-piece hard shell capsules made from hypromellose (or hydroxypropyl methylcellulose, HPMC) have been proposed as an alternative to conventional gelatin capsules for oral drug delivery; however, little is known about their in vivo behaviour. The aim of this study was to compare the disintegration of HPMC and gelatin capsules in fasted human subjects using the technique of gamma scintigraphy. HPMC capsules containing carrageenan as a gelling agent (QUALI-V(R), Qualicaps) and gelatin capsules (Qualicaps) of size 0 were filled with a lactose-based mixture. The capsules were separately radiolabelled with indium-111 and technetium-99m. Both capsules were administered simultaneously with 180ml water to eight healthy male subjects following an overnight fast. Each volunteer was positioned in front of the gamma camera and sequential 60s images were acquired in a continuous manner for 30min. No differences in the oesophageal transit of the two types of capsules were noted, with the capsules arriving in the stomach in a matter of seconds. All the capsules disintegrated in the stomach. The mean (+/-S.D.) disintegration time for the HPMC capsules was 9+/-2min (range 6-11min). The corresponding mean time for the gelatin capsules was 7+/-4min (range 3-13min). These disintegration times were not significantly different (P=0.108, paired t-test). In conclusion, HPMC and gelatin capsules show rapid and comparable in vivo disintegration times in the fasted state. HPMC capsules containing carrageenan as a gelling agent therefore offer a practical alternative to gelatin capsules as an oral drug delivery carrier.

  6. Scaling effects in spiral capsule robots.

    PubMed

    Liang, Liang; Hu, Rong; Chen, Bai; Tang, Yong; Xu, Yan

    2017-04-01

    Spiral capsule robots can be applied to human gastrointestinal tracts and blood vessels. Because of significant variations in the sizes of the inner diameters of the intestines as well as blood vessels, this research has been unable to meet the requirements for medical applications. By applying the fluid dynamic equations, using the computational fluid dynamics method, to a robot axial length ranging from 10(-5) to 10(-2) m, the operational performance indicators (axial driving force, load torque, and maximum fluid pressure on the pipe wall) of the spiral capsule robot and the fluid turbulent intensity around the robot spiral surfaces was numerically calculated in a straight rigid pipe filled with fluid. The reasonableness and validity of the calculation method adopted in this study were verified by the consistency of the calculated values by the computational fluid dynamics method and the experimental values from a relevant literature. The results show that the greater the fluid turbulent intensity, the greater the impact of the fluid turbulence on the driving performance of the spiral capsule robot and the higher the energy consumption of the robot. For the same level of size of the robot, the axial driving force, the load torque, and the maximum fluid pressure on the pipe wall of the outer spiral robot were larger than those of the inner spiral robot. For different requirements of the operating environment, we can choose a certain kind of spiral capsule robot. This study provides a theoretical foundation for spiral capsule robots.

  7. Capsule HRB-21 postirradiation examination plan

    SciTech Connect

    Packan, N.H.; Kania, M.J.; Shrader, L.G.

    1990-03-01

    Irradiation capsule HRB-21 is a test capsule designed to provide Modular High-Temperature Gas-Cooled Reactor (MHTGR) coated particle fuel performance data under test reactor conditions representative of normal MHTGR operation. The irradiated fuel will also be used for postirradiation heating in a controlled atmosphere allowing acquisition of fission product release data at sustained high temperatures. The in-reactor performance data, the postirradiation examination data, and the postirradiation heating data will be used for the validation of fuel performance models under normal and off-normal operating conditions. The accelerated irradiation is to take place in the High Flux Isotope Reactor (HFIR) at ORNL. This report identifies the procedures to be followed in carrying out the postirradiation disassembly and examination of HRB-21. Included is a description of the capsule, a detailed sequence of steps for disassembly of the capsule, a description of the postirradiation examination techniques to be employed, and specifications for the storage of capsule components and the reporting of results. 9 refs., 6 figs., 2 tabs.

  8. Real gas effects on charging and discharging processes of high pressure pneumatics

    NASA Astrophysics Data System (ADS)

    Luo, Yuxi; Wang, Xuanyin; Ge, Yaozheng

    2013-01-01

    The high pressure pneumatic system has been applied to special industries. It may cause errors when we analyze high pressure pneumatics under ideal gas assumption. However, the real gas effect on the performances of high pressure pneumatics is seldom investigated. In this paper, the real gas effects on air enthalpy and internal energy are estimated firstly to study the real gas effect on the energy conversion. Under ideal gas assumption, enthalpy and internal energy are solely related to air temperature. The estimation result indicates that the pressure enthalpy and pressure internal energy of real pneumatic air obviously decrease the values of enthalpy and internal energy for high pressure pneumatics, and the values of pressure enthalpy and pressure internal energy are close. Based on the relationship among pressure, enthalpy and internal energy, the real gas effects on charging and discharging processes of high pressure pneumatics are estimated, which indicates that the real gas effect accelerates the temperature and pressure decreasing rates during discharging process, and decelerates their increasing rates during charging process. According to the above analysis, and for the inconvenience in building the simulation model for real gas and the difficulty of measuring the detail thermal capacities of pneumatics, a method to compensate the real gas effect under ideal gas assumption is proposed by modulating the thermal capacity of the pneumatic container in simulation. The experiments of switching expansion reduction (SER) for high pressure pneumatics are used to verify this compensating method. SER includes the discharging process of supply tanks and the charging process of expansion tank. The simulated and experimental results of SER are highly consistent. The proposed compensation method provides a convenient way to obtain more realistic simulation results for high pressure pneumatics.

  9. Seismic assessment of buried pipelines

    SciTech Connect

    Al-Chaar, G.; Brady, P.; Fernandez, G.

    1995-12-31

    A structure and its lifelines are closely linked because the disruption of lifeline systems will obstruct emergency service functions that are vitally needed after an earthquake. As an example of the criticality of these systems, the Association of Bay Area Government (ABAG) recorded thousands of leaks in pipelines that resulted in more than twenty million gallons of hazardous materials being released in several recorded earthquakes. The cost of cleaning the spills from these materials was very high. This information supports the development of seismic protection of lifeline systems. The US Army Corps of Engineers Construction Engineering Research Laboratories (USACERL) has, among its missions, the responsibility to develop seismic vulnerability assessment procedures for military installations. Within this mission, a preliminary research program to assess the seismic vulnerability of buried pipeline systems on military installations was initiated. Phase 1 of this research project resulted in two major studies. In the first, evaluating current procedures to seismically design or evaluate existing lifeline systems, the authors found several significant aspects that deserve special consideration and need to be addressed in future research. The second was focused on identifying parameters related to buried pipeline system vulnerability and developing a generalized analytical method to relate these parameters to the seismic vulnerability assessment of existing pipeline systems.

  10. The Classroom to Prison Pipeline

    ERIC Educational Resources Information Center

    Christensen, Linda

    2012-01-01

    The school-to-prison pipeline doesn't just begin with cops in the hallways and zero tolerance discipline policies. It begins when teachers fail to create a curriculum and a pedagogy that connects with students, that takes them seriously as intellectuals, that lets students know teachers care about them, that gives them the chance to channel their…

  11. Corrosion beneath disbonded pipeline coatings

    SciTech Connect

    Beavers, J.A.; Thompson, N.G.

    1997-04-01

    The relationship between coatings, cathodic protection (CP), and external corrosion of underground pipelines is described. Historically, this problem has been addressed by focusing on the corrosion and CP processes associated with holidays, e.g., coating disbondment and CP current flow within the disbonded region. These issues and those associated with disbonded areas distant from holidays are also discussed.

  12. Customer service drives pipelines` reorganization

    SciTech Connect

    Share, J.

    1997-06-01

    The concept behind formation of Enron Transportation and Storage tells plenty about this new gas industry. When executives at the Enron Gas Pipeline Group considered plans last year to streamline operations by merging the support functions of Transwestern Pipeline and their other wholly owned pipeline company, Northern Natural Gas, seamless customer service was foremost on their agenda. Instead of worrying about whether employees would favor one pipeline over the other, perhaps to the detriment of customers, they simply created a new organization that everyone would swear the same allegiance to. The 17,000-mile, 4.1 Bcf/d Northern system serves the upper Midwest market and two major expansion projects were completed there last year. Transwestern is a 2,700-mile system with an eastward capacity of 1 Bcf/d and westward of 1.5 Bcf/, that traditionally served California markets. It also ties into Texas intrastate markets and, thanks to expansion of the San Juan lateral, to southern Rocky Mountain supplies. Although Enron Corp. continues to position itself as a full-service energy company, the Gas Pipeline Group continues to fuel much of corporate`s net income, which was $584 million last year. With ET and S comprising a significant portion of GPG`s income, it was vital that the merger of Northern`s 950 employees with Transwestern`s 250 indeed be a seamless one. It was not easy either psychologically or geographically with main offices in Omaha, NE and Houston as well as operations centers in Minneapolis, MN; Amarillo, TX; W. Des Moines, IA; and Albuquerque, NM. But the results have been gratifying, according to William R. Cordes, President of ET and S and Nancy L. Gardner, Executive Vice President of Strategic Initiatives.

  13. Adhesive capsulitis: a review of current treatment.

    PubMed

    Neviaser, Andrew S; Hannafin, Jo A

    2010-11-01

    Adhesive capsulitis is characterized by a painful, gradual loss of both active and passive glenohumeral motion resulting from progressive fibrosis and ultimate contracture of the glenohumeral joint capsule. Variable nomenclature, inconsistent reporting of disease staging, and a multitude of different treatments have created a confusing and contradictory body of literature about this condition. Our purpose is to review the evidence for both nonsurgical and surgical management of adhesive capsulitis with an emphasis on level I and II studies when available. Significant deficits in the literature include a paucity of randomized controlled trials, failure to report response to treatment in a stage-based fashion, and an incomplete understanding of the disease's natural course. Recognition that the clinical stages reflect a progression in the underlying pathological changes should guide future treatments.

  14. Unsteady Pressures on a Generic Capsule Shape

    NASA Technical Reports Server (NTRS)

    Burnside, Nathan; Ross, James C.

    2015-01-01

    While developing the aerodynamic database for the Orion spacecraft, the low-speed flight regime (transonic and below) proved to be the most difficult to predict and measure accurately. The flow over the capsule heat shield in descent flight was particularly troublesome for both computational and experimental efforts due to its unsteady nature and uncertainty about the boundary layer state. The data described here were acquired as part of a study to improve the understanding of the overall flow around a generic capsule. The unsteady pressure measurements acquired on a generic capsule shape are presented along with a discussion about the effects of various flight conditions and heat-shield surface roughness on the resulting pressure fluctuations.

  15. Spectral measurements of asymmetrically irradiated capsule backlighters

    NASA Astrophysics Data System (ADS)

    Keiter, P. A.; Drake, R. P.

    2016-11-01

    Capsule backlighters provide a quasi-continuum x-ray spectrum over a wide range of photon energies [J. F. Hansen et al., Rev. Sci. Instrum. 79, 013504 (2008)]. Ideally one irradiates the capsule backlighter symmetrically, however, in complex experimental geometries, this is not always possible. In recent experiments we irradiated capsule backlighters asymmetrically and measured the x-ray spectrum from multiple directions. We will present time-integrated spectra over the photon energy range of 2-13 keV and time-resolved spectra over the photon energy range of 2-3 keV. We will compare the spectra from different lines of sight to determine if the laser asymmetry results in an angular dependence in the x-ray emission.

  16. Spectral measurements of asymmetrically irradiated capsule backlighters

    DOE PAGES

    Keiter, P. A.; Drake, R. P.

    2016-09-09

    Capsule backlighters provide a quasi-continuum x-ray spectrum over a wide range of photon energies. Ideally one irradiates the capsule backlighter symmetrically, however, in complex experimental geometries, this is not always possible. In recent experiments we irradiated capsule backlighters asymmetrically and measured the x-ray spectrum from multiple directions. We will present time-integrated spectra over the photon energy range of ~2-13 keV and time-resolved spectra over the photon energy range of ~2-3 keV. Lastly, we will compare the spectra from different lines of sight to determine if the laser asymmetry results in an angular dependence in the x-ray emission.

  17. Capsule endoscopy—A mechatronics perspective

    NASA Astrophysics Data System (ADS)

    Lin, Lin; Rasouli, Mahdi; Kencana, Andy Prima; Tan, Su Lim; Wong, Kai Juan; Ho, Khek Yu; Phee, Soo Jay

    2011-03-01

    The recent advances in integrated circuit technology, wireless communication, and sensor technology have opened the door for development of miniature medical devices that can be used for enhanced monitoring and treatment of medical conditions. Wireless capsule endoscopy is one of such medical devices that has gained significant attention during the past few years. It is envisaged that future wireless capsule endoscopies replace traditional endoscopy procedures by providing advanced functionalities such as active locomotion, body fluid/tissue sampling, and drug delivery. Development of energy-efficient miniaturized actuation mechanisms is a key step toward achieving this goal. Here, we review some of the actuators that could be integrated into future wireless capsules and discuss the existing challenges.

  18. Performance optimization of a pneumatic wave energy conversion device

    NASA Astrophysics Data System (ADS)

    Surko, S. W.

    1982-08-01

    The purpose of this study was, for the first time, to optimize the performance of a pneumatic wave energy conversion device. The experiments of Jolly and Newmaster (1979) and Trop and Casey (1980) left a capture chamber and turbine for further investigation. To optimize the system performance the turbine had to be first analyzed so that its power performance curves could be determined. These curves were needed to help define the possible overall performance of the system, and for the impedance matching of the system necessary for performance optimization. With this knowledge, an appropriate generator was purchased and a generator-turbine linkage designed and built. The completed system was then analyzed in the 380 ft wave tank at the U.S. Naval Academy to establish its optimum performance. From the research it is clear that pneumatic wave energy conversion is a promising concept. With several hundred of these devices situated some 100 km off the coast of the Pacific Northwest each device would be producing from 50 to 200 kW which would be transferred back to shore.

  19. Pneumatic interactive gait rehabilitation orthosis: design and preliminary testing.

    PubMed

    Belforte, G; Eula, G; Appendino, S; Sirolli, S

    2011-02-01

    Motor rehabilitation techniques based on passive movement of the lower limbs have been developed over the past 15 years. Gait training automation is the latest innovation in these techniques. This paper describes the design and development of a pneumatic interactive gait rehabilitation orthosis (PIGRO), as well as the first experimental results obtained with healthy subjects. PIGRO consists of a modular and size-adaptable exoskeleton, pneumatic actuation systems for the six actuated degrees of freedom (DoF), and a control unit. The foot orthosis and ankle actuation can be removed and/or replaced with orthopaedic shoes so as to permit gait rehabilitation while advancing between parallel bars with ground contact and partial body weight support (i.e. not walking in place). Control logic provides closed-loop position control independently on each joint, with position feedback for each joint in real time. Imposed curves are physiological joint angles: it is also possible to choose between activating one or both legs and to modify curves to obtain different gait patterns if required. The paper concludes with a presentation of experimental results for the device's performance.

  20. Development of an air pneumatic suspension system for transtibial prostheses.

    PubMed

    Pirouzi, Gholamhossein; Abu Osman, Noor Azuan; Oshkour, Azim Ataollahi; Ali, Sadeeq; Gholizadeh, Hossein; Abas, Wan A B Wan

    2014-09-09

    The suspension system and socket fitting of artificial limbs have major roles and vital effects on the comfort, mobility, and satisfaction of amputees. This paper introduces a new pneumatic suspension system that overcomes the drawbacks of current suspension systems in donning and doffing, change in volume during daily activities, and pressure distribution in the socket-stump interface. An air pneumatic suspension system (APSS) for total-contact sockets was designed and developed. Pistoning and pressure distribution in the socket-stump interface were tested for the new APSS. More than 95% of the area between each prosthetic socket and liner was measured using a Tekscan F-Scan pressure measurement which has developed matrix-based pressure sensing systems. The variance in pressure around the stump was 8.76 kPa. APSS exhibits less pressure concentration around the stump, improved pressure distribution, easy donning and doffing, adjustability to remain fitted to the socket during daily activities, and more adaptability to the changes in stump volume. The volume changes were adjusted by utility of air pressure sensor. The vertical displacement point and reliability of suspension were assessed using a photographic method. The optimum pressure in every level of loading weight was 55 kPa, and the maximum displacement was 6 mm when 90 N of weight was loaded.

  1. Prognostics for Ground Support Systems: Case Study on Pneumatic Valves

    NASA Technical Reports Server (NTRS)

    Daigle, Matthew; Goebel, Kai

    2011-01-01

    Prognostics technologies determine the health (or damage) state of a component or sub-system, and make end of life (EOL) and remaining useful life (RUL) predictions. Such information enables system operators to make informed maintenance decisions and streamline operational and mission-level activities. We develop a model-based prognostics methodology for pneumatic valves used in ground support equipment for cryogenic propellant loading operations. These valves are used to control the flow of propellant, so failures may have a significant impact on launch availability. Therefore, correctly predicting when valves will fail enables timely maintenance that avoids launch delays and aborts. The approach utilizes mathematical models describing the underlying physics of valve degradation, and, employing the particle filtering algorithm for joint state-parameter estimation, determines the health state of the valve and the rate of damage progression, from which EOL and RUL predictions are made. We develop a prototype user interface for valve prognostics, and demonstrate the prognostics approach using historical pneumatic valve data from the Space Shuttle refueling system.

  2. Independence of biomechanical forces and craniofacial pneumatization in Cebus.

    PubMed

    Rae, Todd C; Koppe, Thomas

    2008-11-01

    Several different factors have been hypothesized as explanations of variation in primate paranasal sinus size. Biomechanical forces, particularly those associated with mastication, are frequently evoked to account for differences in primate craniofacial pneumatization. To test whether masticatory stresses are responsible for maxillary sinus volume diversity, two platyrrhine species of the genus Cebus (C. apella and C. albifrons) were examined. The former has been identified as a hard object feeder, and many morphological differences between the two species are attributable to differences in the mechanical properties of their respective diets. Sinus volumes were derived from serial coronal CT scans of the crania of adults. Several external cranial measurements were used to scale sinus volume relative to the size of the face. Relative measures of maxillary sinus volume were compared using standard statistical techniques. In all comparisons, the two capuchin species do not differ from one another significantly at P < 0.05. Thus, this "natural experiment" fails to support the interpretation that biomechanical forces acting on the facial skeleton substantially affect the degree of paranasal pneumatization in primates. This result suggests that it is unlikely that the maxillary sinus performs any function in relation to masticatory stress; other factors must be responsible for the variation in sinus volume among primates.

  3. Pneumatic oscillator circuits for timing and control of integrated microfluidics.

    PubMed

    Duncan, Philip N; Nguyen, Transon V; Hui, Elliot E

    2013-11-05

    Frequency references are fundamental to most digital systems, providing the basis for process synchronization, timing of outputs, and waveform synthesis. Recently, there has been growing interest in digital logic systems that are constructed out of microfluidics rather than electronics, as a possible means toward fully integrated laboratory-on-a-chip systems that do not require any external control apparatus. However, the full realization of this goal has not been possible due to the lack of on-chip frequency references, thus requiring timing signals to be provided from off-chip. Although microfluidic oscillators have been demonstrated, there have been no reported efforts to characterize, model, or optimize timing accuracy, which is the fundamental metric of a clock. Here, we report pneumatic ring oscillator circuits built from microfluidic valves and channels. Further, we present a compressible-flow analysis that differs fundamentally from conventional circuit theory, and we show the utility of this physically based model for the optimization of oscillator stability. Finally, we leverage microfluidic clocks to demonstrate circuits for the generation of phase-shifted waveforms, self-driving peristaltic pumps, and frequency division. Thus, pneumatic oscillators can serve as on-chip frequency references for microfluidic digital logic circuits. On-chip clocks and pumps both constitute critical building blocks on the path toward achieving autonomous laboratory-on-a-chip devices.

  4. Development of an Air Pneumatic Suspension System for Transtibial Prostheses

    PubMed Central

    Pirouzi, Gholamhossein; Osman, Noor Azuan Abu; Oshkour, Azim Ataollahi; Ali, Sadeeq; Gholizadeh, Hossein; Wan Abas, Wan A. B.

    2014-01-01

    The suspension system and socket fitting of artificial limbs have major roles and vital effects on the comfort, mobility, and satisfaction of amputees. This paper introduces a new pneumatic suspension system that overcomes the drawbacks of current suspension systems in donning and doffing, change in volume during daily activities, and pressure distribution in the socket-stump interface. An air pneumatic suspension system (APSS) for total-contact sockets was designed and developed. Pistoning and pressure distribution in the socket-stump interface were tested for the new APSS. More than 95% of the area between each prosthetic socket and liner was measured using a Tekscan F-Scan pressure measurement which has developed matrix-based pressure sensing systems. The variance in pressure around the stump was 8.76 kPa. APSS exhibits less pressure concentration around the stump, improved pressure distribution, easy donning and doffing, adjustability to remain fitted to the socket during daily activities, and more adaptability to the changes in stump volume. The volume changes were adjusted by utility of air pressure sensor. The vertical displacement point and reliability of suspension were assessed using a photographic method. The optimum pressure in every level of loading weight was 55 kPa, and the maximum displacement was 6 mm when 90 N of weight was loaded. PMID:25207872

  5. Water Landing Characteristics of a Reentry Capsule

    NASA Technical Reports Server (NTRS)

    1958-01-01

    Experimental and theoretical investigations have been made to determine the water-landing characteristics of a conical-shaped reentry capsule having a segment of a sphere as the bottom. For the experimental portion of the investigation, a 1/12-scale model capsule and a full-scale capsule were tested for nominal flight paths of 65 deg and 90 deg (vertical), a range of contact attitudes from -30 deg to 30 deg, and a full-scale vertical velocity of 30 feet per second at contact. Accelerations were measured by accelerometers installed at the centers of gravity of the model and full-scale capsules. For the model test the accelerations were measured along the X-axis (roll) and Z-axis (yaw) and for the full-scale test they were measured along the X-axis (roll), Y-axis (pitch), and Z-axis (yaw). Motions and displacements of the capsules that occurred after contact were determined from high-speed motion pictures. The theoretical investigation was conducted to determine the accelerations that might occur along the X-axis when the capsule contacted the water from a 90 deg flight path at a 0 deg attitude. Assuming a rigid body, computations were made from equations obtained by utilizing the principle of the conservation of momentum. The agreement among data obtained from the model test, the full-scale test, and the theory was very good. The accelerations along the X-axis, for a vertical flight path and 0 deg attitude, were in the order of 40g. For a 65 deg flight path and 0 deg attitude, the accelerations along the X-axis were in the order of 50g. Changes in contact attitude, in either the positive or negative direction from 0 deg attitude, considerably reduced the magnitude of the accelerations measured along the X-axis. Accelerations measured along the Y- and Z-axes were relatively small at all test conditions.

  6. Video capsule endoscopy in inflammatory bowel disease

    PubMed Central

    Collins, Paul D

    2016-01-01

    Video capsule endoscopy (VCE) has evolved to become an important tool for the non-invasive examination of the small bowel, which hitherto had been relatively inaccessible to direct visualisation. VCE has been shown to play a role in monitoring the activity of small bowel Crohn’s disease and can be used to assess the response to anti-inflammatory treatment in Crohn’s disease. For those patients with Crohn’s disease who have undergone an intestinal resection, VCE has been assessed as a tool to detect post-operative recurrence. VCE may also aid in the reclassification of patients with a diagnosis of Inflammatory Bowel Disease Unclassified to Crohn’s disease. The evolution of colon capsule endoscopy (CCE) has expanded the application of this technology further. The use of CCE to assess the activity of ulcerative colitis has been described. This advance in capsule technology has also fuelled interest in its potential role as a minimally invasive tool to assess the whole of GI tract opening the possibility of its use for the panenteric assessment of Crohn’s disease. VCE is a safe procedure. However, the risk of a retained capsule is higher in patients with suspected or confirmed Crohn’s disease compared with patients having VCE examination for other indications. A retained video capsule is rare after successful passage of a patency capsule which may be utilised to pre-screen patients undergoing VCE. This paper describes the use of VCE in the assessment of inflammatory bowel disease. PMID:27499830

  7. The MIRI Medium Resolution Spectrometer calibration pipeline

    NASA Astrophysics Data System (ADS)

    Labiano, A.; Azzollini, R.; Bailey, J.; Beard, S.; Dicken, D.; García-Marín, M.; Geers, V.; Glasse, A.; Glauser, A.; Gordon, K.; Justtanont, K.; Klaassen, P.; Lahuis, F.; Law, D.; Morrison, J.; Müller, M.; Rieke, G.; Vandenbussche, B.; Wright, G.

    2016-07-01

    The Mid-Infrared Instrument (MIRI) Medium Resolution Spectrometer (MRS) is the only mid-IR Integral Field Spectrometer on board James Webb Space Telescope. The complexity of the MRS requires a very specialized pipeline, with some specific steps not present in other pipelines of JWST instruments, such as fringe corrections and wavelength offsets, with different algorithms for point source or extended source data. The MRS pipeline has also two different variants: the baseline pipeline, optimized for most foreseen science cases, and the optimal pipeline, where extra steps will be needed for specific science cases. This paper provides a comprehensive description of the MRS Calibration Pipeline from uncalibrated slope images to final scientific products, with brief descriptions of its algorithms, input and output data, and the accessory data and calibration data products necessary to run the pipeline.

  8. External pipeline coating selection for new and existing buried pipelines

    SciTech Connect

    Brown, M.D.

    1996-12-31

    The majority of existing and new pipelines are externally coated. The opportunity to examine buried pipelines has shown that selection of both shop and over-the-ditch field applied coatings has resulted in many failures. Coating selection in 19896 has become more complex because of the abundance of available products. Not only are there many available coating types but there are also competitive products within each category. The safe approach is to select a coating that will perform well under the most severe conditions but this approach can be very costly and often a lesser coating is selected with the realization that it affects the risk of failure. This paper addresses the criteria that need to be considered during coating selection and provides an outline for the decision making process. Examples are used to illustrate the effect of different factors on coating performance.

  9. Urban pipelining project; Mueller pipeliners working in Detroit suburbs

    SciTech Connect

    Not Available

    1988-06-01

    This paper describes how Mueller Pipeliners Inc., is helping Consumers Power Co. renovate and strengthen its system in the northern Detroit suburb of Sterling Heights. Consumers Power is enhancing its system in Sterling Heights with the addition of 10,700 ft of coated steel pipe and 6,000 ft of plastic pipe. The new lines will replace part of the existing system and improve the utility's ability to serve new customers in the rapidly expanding area.

  10. Dynamic Friction Performance of a Pneumatic Cylinder with Al2O3 Film on Cylinder Surface.

    PubMed

    Chang, Ho; Lan, Chou-Wei; Wang, Hao-Xian

    2015-11-01

    A friction force system is proposed for accurately measuring friction force and motion properties produced by reciprocating motion of piston in a pneumatic cylinder. In this study, the proposed system is used to measure the effects of lubricating greases of different viscosities on the friction properties of pneumatic cylinder, and improvement of stick-slip motion for the cylinder bore by anodizing processes. A servo motor-driven ball screw is used to drive the pneumatic cylinder to be tested and to measure the change in friction force of the pneumatic cylinder. Experimental results show, that under similar test conditions, the lubricating grease with viscosity VG100 is best suited for measuring reciprocating motion of the piston of pneumatic cylinder. The wear experiment showed that, in the Al2O3 film obtained at a preset voltage 40 V in the anodic process, the friction coefficient and hardness decreased by 55% and increased by 274% respectively, thus achieving a good tribology and wear resistance. Additionally, the amplitude variation in the friction force of the pneumatic cylinder wall that received the anodizing treatment was substantially reduced. Additionally, the stick-slip motion of the pneumatic cylinder during low-speed motion was substantially improved.

  11. 21 CFR 872.3110 - Dental amalgam capsule.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Dental amalgam capsule. 872.3110 Section 872.3110...) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3110 Dental amalgam capsule. (a) Identification. A dental amalgam capsule is a container device in which silver alloy is intended to be mixed with...

  12. 21 CFR 520.446 - Clindamycin capsules and tablets.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... capsules and tablets. (a) Specifications(1) Each capsule contains the equivalent of 25, 75, 150, or 300 milligrams (mg) clindamycin as the hydrochloride salt. (2) Each tablet contains the equivalent of 25, 75, or 150 mg clindamycin as the hydrochloride salt. (3) Each capsule contains the equivalent of 25, 75,...

  13. 21 CFR 520.608 - Dicloxacillin sodium monohydrate capsules.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 6 2012-04-01 2012-04-01 false Dicloxacillin sodium monohydrate capsules. 520.608 Section 520.608 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... Dicloxacillin sodium monohydrate capsules. (a) Specifications. Each capsule contains dicloxacillin...

  14. 21 CFR 520.608 - Dicloxacillin sodium monohydrate capsules.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Dicloxacillin sodium monohydrate capsules. 520.608 Section 520.608 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... Dicloxacillin sodium monohydrate capsules. (a) Specifications. Each capsule contains dicloxacillin...

  15. 21 CFR 520.608 - Dicloxacillin sodium monohydrate capsules.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 6 2013-04-01 2013-04-01 false Dicloxacillin sodium monohydrate capsules. 520.608 Section 520.608 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... Dicloxacillin sodium monohydrate capsules. (a) Specifications. Each capsule contains dicloxacillin...

  16. 21 CFR 520.622d - Diethylcarbamazine citrate capsules.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 6 2013-04-01 2013-04-01 false Diethylcarbamazine citrate capsules. 520.622d... Diethylcarbamazine citrate capsules. (a) Specifications. Each capsule contains 12.5, 50, 200, or 400 milligrams (mg) diethylcarbamazine citrate. (b) Sponsor. See No. 011014 in § 510.600(c) of this chapter. (c) Conditions of use...

  17. Capsule endoscopy of the small bowel

    PubMed Central

    Ching, Hey-Long; Yung, Diana; Sidhu, Reena; Koulaouzidis, Anastasios

    2016-01-01

    Capsule endoscopy (CE) is a first line small bowel investigative modality which provides more sensitive mucosal imaging than comparators. It is a non-invasive, non-irradiating tool well tolerated by patients. The risk of retention of the capsule can be minimised by ensuring luminal patency using the Agile patency device. Research continues into how to minimise missed pathology and variability in the identification of pathology or interpretation of images. The consensus is that bowel preparation using laxatives improves visibility and diagnostic yield. Research includes the development of image recognition software, both to eliminate sequentially identical images to improve viewing speed and to select or enhance images likely to represent pathology. However, careful reading by experienced capsule endoscopists remains the benchmark. This should be performed at a speed comfortable to the viewer, probably at a maximum of 15 frames per second. Some prior experience of endoscopy appears to be helpful for novice capsule endoscopists and formal training on a hands-on training course seems to improve pathology recognition, for novices and for those with CE experience. PMID:27826572

  18. Capsule endoscopy in patients refusing conventional endoscopy

    PubMed Central

    Romero-Vázquez, Javier; Argüelles-Arias, Federico; García-Montes, Josefa Maria; Caunedo-Álvarez, Ángel; Pellicer-Bautista, Francisco Javier; Herrerías-Gutiérrez, Juan Manuel

    2014-01-01

    Capsule endoscopy is nowadays the diagnostic technique of choice in the study of small bowel pathologies, allowing the non-invasive study of the entire mucosa. This has led, together with new technical advances, to the creation of two new models (PillCam ESO and PillCam Colon) for the study of esophageal and colonic diseases. These two new capsules offer an interesting alternative to conventional endoscopy in the study of the upper and lower digestive tracts, because traditional endoscopy is often unpleasant and uncomfortable for the patient, can be painful, often requires moderate or deep sedation and is not without complications (hemorrhage, perforation, etc.). PillCam Colon is particularly important for its usefulness in the diagnosis of colonic polyps, and is a potentially useful tool in cases of incomplete colonoscopy or in colorectal cancer screening, even more when most patients are reluctant to undergo screening programs due to the said disadvantages of conventional colonoscopy. This article discusses the advantages of capsule endoscopy over conventional endoscopy, its current application possibilities and indications in routine clinical practice. In the various sections of the work, we assess the application of endoscopic capsule in different sections of the digestive tract (esophagus, stomach, and colon) and finally the potential role of panendoscopy with PillCam Colon. PMID:24966612

  19. Design of Endoscopic Capsule With Multiple Cameras.

    PubMed

    Gu, Yingke; Xie, Xiang; Li, Guolin; Sun, Tianjia; Wang, Dan; Yin, Zheng; Zhang, Pengfei; Wang, Zhihua

    2015-08-01

    In order to reduce the miss rate of the wireless capsule endoscopy, in this paper, we propose a new system of the endoscopic capsule with multiple cameras. A master-slave architecture, including an efficient bus architecture and a four level clock management architecture, is applied for the Multiple Cameras Endoscopic Capsule (MCEC). For covering more area of the gastrointestinal tract wall with low power, multiple cameras with a smart image capture strategy, including movement sensitive control and camera selection, are used in the MCEC. To reduce the data transfer bandwidth and power consumption to prolong the MCEC's working life, a low complexity image compressor with PSNR 40.7 dB and compression rate 86% is implemented. A chipset is designed and implemented for the MCEC and a six cameras endoscopic capsule prototype is implemented by using the chipset. With the smart image capture strategy, the coverage rate of the MCEC prototype can achieve 98% and its power consumption is only about 7.1 mW.

  20. Efficient Method for Calculating Hydraulic Conductivity from Pneumatic Slug Tests

    NASA Astrophysics Data System (ADS)

    Peng, X.; Cheung, B.; Knappett, P. S.; Zhan, H.

    2014-12-01

    Pneumatic slug tests are widely used in characterizing the hydraulic conductivity of aquifers. In comparison to a manual slug test wherein the water level is measured using a water level tape, pneumatic slug tests are especially useful when the water level recovery is very fast (<10 sec) in a high hydraulic conductivity (K) aquifer (>10-4 m/s) and when the recovery is very slow (<10-7 m/s). The submerged pressure transducer monitors pressure changes at intervals of fractions of a second and for longer recoveries no personnel are required to make repeated measurements. A pneumatic slug test begins with pressurizing the well at the well head using an air pump followed by several minutes waiting for the pressure in the well to equalize with the pressure outside the well screen. In semi-confined settings this equalization may take >5 minutes. In lower K media it's not always feasible to wait until the well fully recovers before making the next replicate measurement. Therefore, it would greatly reduce the time needed to make replicate measurements if these waiting times could be reduced. Here we present a method using non-linear least squares regression on a portion of the recovery curve to simultaneously fit 3 parameters used to determine K from a slug tests using the Hvorslev method. The advantage of this approach is that waiting for the well to reach static head between replicate measurements is not required. This is because the regression fits static head (H) from the shape of only part the recovery curve. We compare the resulting K values from this new method to values obtained from manually measured static heads for triplicate measurements on 50 wells. The well's settings ranged from unconfined to semi-confined and K ranged from 10-3 to 10-5 m/s. The new method gave identical results. We performed the same comparison on a subset 16 wells using data collected in half the time, where only part of the recovery curves were measured before starting the next replicate

  1. Water Landing Characteristics of a Reentry Capsule

    NASA Technical Reports Server (NTRS)

    1958-01-01

    Water Landing Characteristics of a Reentry Capsule. Experimental and theoretical investigations have been made to determine the water-landing characteristics of a conical-shaped reentry capsule having a segment of a sphere as the bottom. For the experimental portion of the investigation, a 1/12-scale model capsule and a full-scale capsule were tested for nominal flight paths of 65 deg and 90 deg (vertical), a range of contact attitudes from -30 deg to 30 deg, and a full-scale vertical velocity of 30 feet per second at contact. Accelerations were measured by accelerometers installed at the centers of gravity of the model and full-scale capsules. For the model test the accelerations were measured along the X-axis (roll) and Z-axis (yaw) and for the full-scale test they were measured along the X-axis (roll), Y-axis (pitch), and Z-axis (yaw). Motions and displacements of the capsules that occurred after contact were determined from high-speed motion pictures. The theoretical investigation was conducted to determine the accelerations that might occur along the X-axis when the capsule contacted the water from a 90 deg flight path at a 0 deg attitude. Assuming a rigid body, computations were made from equations obtained by utilizing the principle of the conservation of momentum. The agreement among data obtained from the model test, the full-scale test, and the theory was very good. The accelerations along the X-axis, for a vertical flight path and 0 deg attitude, were in the order of 40g. For a 65 deg flight path and 0 deg attitude, the accelerations along the X-axis were in the order of 50g. Changes in contact attitude, in either the positive or negative direction from 0 deg attitude, considerably reduced the magnitude of the accelerations measured along the X-axis. Accelerations measured along the Y- and Z-axes were relatively small at all test conditions. [Entire movie available on DVD from CASI as Doc ID 20070030955. Contact help@sti.nasa.gov

  2. Portal venous gas and cardiopulmonary arrest during pneumatic reduction of an ileocolic intussusception.

    PubMed

    Ryan, Mark L; Fields, Jonathan M; Sola, Juan E; Neville, Holly L

    2011-04-01

    We present the case of an 8-month-old infant with a small bowel obstruction secondary to an ileocolic intussusception without a pathologic lead point. During pneumatic reduction, the patient went into cardiopulmonary arrest, at which point portal venous gas (PVG) was visualized on radiography. Here we present-to our knowledge-the first reported case of PVG secondary to pneumatic reduction of an intussusception along with a review of the literature regarding known complications of pneumatic reduction and the etiologies of PVG.

  3. Presence of a capsule in Neisseria lactamica, antigenically similar to the capsule of N. meningitidis.

    PubMed

    Martin, P V; Laviotola, A; Ohayon, H; Riou, J Y

    1986-01-01

    Three of thirteen strains of Neisseria lactamica, a species closely related to N. meningitidis, were selected on the basis of their ability to be strongly agglutinated by serogroup B antimeningococcal serum. The presence of a capsule was demonstrated using Alcian blue as a stain for acidic polysaccharide. When reacted with serogroup B antimeningococcal sera, 2 out of 3 N. lactamica B-coagglutanating strains exhibited an extracellular material comparable in size, antigenicity and staining properties to the capsule of serogroup B N. meningitidis.

  4. Threshold-avoiding proteomics pipeline.

    PubMed

    Suits, Frank; Hoekman, Berend; Rosenling, Therese; Bischoff, Rainer; Horvatovich, Peter

    2011-10-15

    We present a new proteomics analysis pipeline focused on maximizing the dynamic range of detected molecules in liquid chromatography-mass spectrometry (LC-MS) data and accurately quantifying low-abundance peaks to identify those with biological relevance. Although there has been much work to improve the quality of data derived from LC-MS instruments, the goal of this study was to extend the dynamic range of analyzed compounds by making full use of the information available within each data set and across multiple related chromatograms in an experiment. Our aim was to distinguish low-abundance signal peaks from noise by noting their coherent behavior across multiple data sets, and central to this is the need to delay the culling of noise peaks until the final peak-matching stage of the pipeline, when peaks from a single sample appear in the context of all others. The application of thresholds that might discard signal peaks early is thereby avoided, hence the name TAPP: threshold-avoiding proteomics pipeline. TAPP focuses on quantitative low-level processing of raw LC-MS data and includes novel preprocessing, peak detection, time alignment, and cluster-based matching. We demonstrate the performance of TAPP on biologically relevant sample data consisting of porcine cerebrospinal fluid spiked over a wide range of concentrations with horse heart cytochrome c.

  5. Kinetic simulation of hydrodynamic equivalent capsule implosions

    NASA Astrophysics Data System (ADS)

    Kwan, Thomas; Le, Ari; Schmitt, Mark; Herrmann, Hans

    2016-10-01

    We have carried out simulations of direct-drive hydrodynamic equivalent capsule implosion experiments conducted on Omega laser facility at the Laboratory of Laser Energetics of the University of Rochester. The capsules had a glass shell (SiO2) 4.87 μm with an inner diameter of 1086 μm. One was filled with deuterium (D) and tritium (T) at 6.635 and 2.475 atmospheric pressure respectively. The other capsule with D, T, and He-3 at 2.475, 2.475, and 5.55 atmospheric pressure respectively. The capsules were imploded with 60 laser beams with a square pulse length of 0.6ns of total energy of 15.6 kJ. One-dimensional radiation hydrodynamic calculations with HYDRA and kinetic particle/hybrid simulations with LSP are carried out for the post-shot analysis. HYDRA outputs at 0.6ns are linked to LSP, in which the electrons are treated as a fluid while all the ion dynamics is simulated by the standard particle-in-cell technique. Additionally, simulations with the new photon package in LSP are initiated at the beginning of the implosion to include the implosion phase of the capsule. The simulation results of density, temperature, and velocity profiles of the electrons, D, T, He-3, and SiO2species are compared with HYDRA. Detail comparisons among the kinetic simulations, rad-hydro simulations, and experimental results of neutron yield, yield ratio, fusion burn histories, and shell convergence will be presented to assess plasma kinetic effects. Work performed under the auspices of the US DOE by the Los Alamos National Laboratory under Contract No. W7405-ENG-36.

  6. The role of particle collisions in pneumatic transport

    NASA Astrophysics Data System (ADS)

    Mastorakos, E.; Louge, M.; Jenkins, J. T.

    1989-09-01

    A model of dilute gas-solid flow in vertical risers is developed in which the particle phase is treated as a granular material, the balance equations for rapid granular flow are modified to incorporate the drag force from the gas, and boundary conditions, based on collisional exchanges of momentum and energy at the wall, are employed. In this model, it is assumed that the particle fluctuations are determined by inter-particle collisions only and that the turbulence of the gas is unaffected by the presence of the particles. The model is developed in the context of, but not limited to, steady, fully developed flow. A numerical solution of the resulting governing equations provides concentration profiles generally observed in dilute pneumatic flow, velocity profiles in good agreement with the measurements of Tsuji, et al. (1984), and an explanation for the enhancement of turbulence that they observed.

  7. Pneumatic Micro Dispenser Chip for Portable Micro Analysis Devices

    NASA Astrophysics Data System (ADS)

    Hasegawa, Tadahiro; Tsuji, Toshiyuki; Ikuta, Koji

    The prototype of the pneumatic micro dispenser chip for portable micro analysis devices was developed successfully. This micro dispenser succeeded to divide liquid into 1µL without any dead volume by decompressing and the compressing air in only one micro pump. The dispensing operation is achieved by the original micro liquid detecting method and four hat-shaped check valves. The detecting method utilized the refraction of the infrared rays LED. Not only passage of the fluid into the channel but also its existence can be detected as TTL level signal. The hat-shaped silicone rubber valve which functions itself as a unidirectional passive valve was proposed. The check valve with low opening pressure (3kPa) and high inverse pressure (over 300kPa) was developed successfully. This micro dispenser chip is useful for portable micro analysis devices.

  8. A high performance pneumatic braking system for heavy vehicles

    NASA Astrophysics Data System (ADS)

    Miller, Jonathan I.; Cebon, David

    2010-12-01

    Current research into reducing actuator delays in pneumatic brake systems is opening the door for advanced anti-lock braking algorithms to be used on heavy goods vehicles. However, these algorithms require the knowledge of variables that are impractical to measure directly. This paper introduces a sliding mode braking force observer to support a sliding mode controller for air-braked heavy vehicles. The performance of the observer is examined through simulations and field testing of an articulated heavy vehicle. The observer operated robustly during single-wheel vehicle simulations, and provided reasonable estimates of surface friction from test data. The effect of brake gain errors on the controller and observer are illustrated, and a recursive least squares estimator is derived for the brake gain. The estimator converged within 0.3 s in simulations and vehicle trials.

  9. The role of particle collisions in pneumatic transport

    NASA Technical Reports Server (NTRS)

    Mastorakos, E.; Louge, M.; Jenkins, J. T.

    1989-01-01

    A model of dilute gas-solid flow in vertical risers is developed in which the particle phase is treated as a granular material, the balance equations for rapid granular flow are modified to incorporate the drag force from the gas, and boundary conditions, based on collisional exchanges of momentum and energy at the wall, are employed. In this model, it is assumed that the particle fluctuations are determined by inter-particle collisions only and that the turbulence of the gas is unaffected by the presence of the particles. The model is developed in the context of, but not limited to, steady, fully developed flow. A numerical solution of the resulting governing equations provides concentration profiles generally observed in dilute pneumatic flow, velocity profiles in good agreement with the measurements of Tsuji, et al. (1984), and an explanation for the enhancement of turbulence that they observed.

  10. Design of a biped robot actuated by pneumatic artificial muscles.

    PubMed

    Liu, Yixiang; Zang, Xizhe; Liu, Xinyu; Wang, Lin

    2015-01-01

    High compliant legs are essential for the efficient versatile locomotion and shock absorbency of humans. This study proposes a biped robot actuated by pneumatic artificial muscles to mimic human locomotion. On the basis of the musculoskeletal architecture of human lower limbs, each leg of the biped robot is modeled as a system of three segments, namely, hip joint, knee joint, and ankle joint, and eleven muscles, including both monoarticular and biarticular muscles. Each rotational joint is driven by a pair of antagonistic muscles, enabling joint compliance to be tuned by operating the pressure inside the muscles. Biarticular muscles play an important role in transferring power between joints. Walking simulations verify that biarticular muscles contribute to joint compliance and can absorb impact energy when the robot makes an impact upon ground contact.

  11. Preliminary measurements on heat balance in pneumatic tires

    NASA Technical Reports Server (NTRS)

    Nybakken, G. H.; Collart, D. Y.; Staples, R. J.; Lackey, J. I.; Clark, S. K.; Dodge, R. N.

    1973-01-01

    A variety of tests was undertaken to determine the nature of heat generation associated with a pneumatic tire operating under various conditions. Tests were conducted to determine the magnitude and distribution of internally generated heat caused by hysteresis in the rubber and ply fabric in an automobile tire operating under conditions of load, pressure, and velocity representative of normal operating conditions. These included tests at various yaw angles and tests with braking applied. In other tests, temperature sensors were mounted on a road to measure the effect of a tire rolling over and an attempt was made to deduce the magnitude and nature of interfacial friction from the resulting information. In addition, tests were performed using the scratch plate technique to determine the nature of the motion between the tire and road. Finally, a model tire was tested on a roadwheel, the surface covering which could be changed, and an optical pyrometer was used to measure rubber surface temperatures.

  12. Analysis of nonlinear elastic behavior in miniature pneumatic artificial muscles

    NASA Astrophysics Data System (ADS)

    Hocking, Erica G.; Wereley, Norman M.

    2013-01-01

    Pneumatic artificial muscles (PAMs) are well known for their excellent actuator characteristics, including high specific work, specific power, and power density. Recent research has focused on miniaturizing this pneumatic actuator technology in order to develop PAMs for use in small-scale mechanical systems, such as those found in robotic or aerospace applications. The first step in implementing these miniature PAMs was to design and characterize the actuator. To that end, this study presents the manufacturing process, experimental characterization, and analytical modeling of PAMs with millimeter-scale diameters. A fabrication method was developed to consistently produce low-cost, high performance, miniature PAMs using commercially available materials. The quasi-static behavior of these PAMs was determined through experimentation on a single actuator with an active length of 39.16 mm (1.54 in) and a diameter of 4.13 mm (0.1625 in). Testing revealed the PAM’s full evolution of force with displacement for operating pressures ranging from 207 to 552 kPa (30-80 psi in 10 psi increments), as well as the blocked force and free contraction at each pressure. Three key nonlinear phenomena were observed: nonlinear PAM stiffness, hysteresis of the force versus displacement response for a given pressure, and a pressure deadband. To address the analysis of the nonlinear response of these miniature PAMs, a nonlinear stress versus strain model, a hysteresis model, and a pressure bias are introduced into a previously developed force balance analysis. Parameters of these nonlinear model refinements are identified from the measured force versus displacement data. This improved nonlinear force balance model is shown to capture the full actuation behavior of the miniature PAMs at each operating pressure and reconstruct miniature PAM response with much more accuracy than previously possible.

  13. New Journal index will measure gas pipeline inflation

    SciTech Connect

    Morgan, J.M.

    1982-09-20

    This article marks the start of a new pipeline cost index, for gas pipelines. Its objective is to complement the Journal's oil pipeline cost index, started with the Nov. 19, 1979 issue. This new gas pipeline cost index will be published quarterly, as will the OGJ MORGAN Oil Pipeline Cost Index.

  14. 30 CFR 250.1005 - Inspection requirements for DOI pipelines.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 30 Mineral Resources 2 2012-07-01 2012-07-01 false Inspection requirements for DOI pipelines. 250... THE INTERIOR OFFSHORE OIL AND GAS AND SULPHUR OPERATIONS IN THE OUTER CONTINENTAL SHELF Pipelines and Pipeline Rights-of-Way § 250.1005 Inspection requirements for DOI pipelines. (a) Pipeline routes shall...

  15. 30 CFR 250.1005 - Inspection requirements for DOI pipelines.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 30 Mineral Resources 2 2014-07-01 2014-07-01 false Inspection requirements for DOI pipelines. 250... THE INTERIOR OFFSHORE OIL AND GAS AND SULPHUR OPERATIONS IN THE OUTER CONTINENTAL SHELF Pipelines and Pipeline Rights-of-Way § 250.1005 Inspection requirements for DOI pipelines. (a) Pipeline routes shall...

  16. 18 CFR 284.142 - Sales by intrastate pipelines.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... pipelines. 284.142 Section 284.142 Conservation of Power and Water Resources FEDERAL ENERGY REGULATORY... RELATED AUTHORITIES Certain Sales by Intrastate Pipelines § 284.142 Sales by intrastate pipelines. Any intrastate pipeline may, without prior Commission approval, sell natural gas to any interstate pipeline...

  17. 30 CFR 250.1005 - Inspection requirements for DOI pipelines.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 2 2010-07-01 2010-07-01 false Inspection requirements for DOI pipelines. 250... OFFSHORE OIL AND GAS AND SULPHUR OPERATIONS IN THE OUTER CONTINENTAL SHELF Pipelines and Pipeline Rights-of-Way § 250.1005 Inspection requirements for DOI pipelines. (a) Pipeline routes shall be inspected...

  18. 30 CFR 250.1005 - Inspection requirements for DOI pipelines.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 30 Mineral Resources 2 2013-07-01 2013-07-01 false Inspection requirements for DOI pipelines. 250... THE INTERIOR OFFSHORE OIL AND GAS AND SULPHUR OPERATIONS IN THE OUTER CONTINENTAL SHELF Pipelines and Pipeline Rights-of-Way § 250.1005 Inspection requirements for DOI pipelines. (a) Pipeline routes shall...

  19. 18 CFR 284.142 - Sales by intrastate pipelines.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... pipelines. 284.142 Section 284.142 Conservation of Power and Water Resources FEDERAL ENERGY REGULATORY... RELATED AUTHORITIES Certain Sales by Intrastate Pipelines § 284.142 Sales by intrastate pipelines. Any intrastate pipeline may, without prior Commission approval, sell natural gas to any interstate pipeline...

  20. 18 CFR 284.142 - Sales by intrastate pipelines.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... pipelines. 284.142 Section 284.142 Conservation of Power and Water Resources FEDERAL ENERGY REGULATORY... RELATED AUTHORITIES Certain Sales by Intrastate Pipelines § 284.142 Sales by intrastate pipelines. Any intrastate pipeline may, without prior Commission approval, sell natural gas to any interstate pipeline...

  1. 18 CFR 284.142 - Sales by intrastate pipelines.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... pipelines. 284.142 Section 284.142 Conservation of Power and Water Resources FEDERAL ENERGY REGULATORY... RELATED AUTHORITIES Certain Sales by Intrastate Pipelines § 284.142 Sales by intrastate pipelines. Any intrastate pipeline may, without prior Commission approval, sell natural gas to any interstate pipeline...

  2. Pipeline incidents and emergency repair in the North Sea

    SciTech Connect

    Wood, G.D.

    1988-12-01

    The failures of submarine pipelines in the North Sea, and the response of pipeline operators are first discussed. Against this background, the methods currently available for submarine pipeline repairs are reviewed. The Emergency Pipeline Repair Services available are described, and some future developments in the field of submarine pipeline repair are briefly outlined.

  3. 49 CFR 195.9 - Outer continental shelf pipelines.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 3 2012-10-01 2012-10-01 false Outer continental shelf pipelines. 195.9 Section... HAZARDOUS LIQUIDS BY PIPELINE General § 195.9 Outer continental shelf pipelines. Operators of transportation pipelines on the Outer Continental Shelf must identify on all their respective pipelines the specific...

  4. 49 CFR 195.9 - Outer continental shelf pipelines.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 3 2013-10-01 2013-10-01 false Outer continental shelf pipelines. 195.9 Section... HAZARDOUS LIQUIDS BY PIPELINE General § 195.9 Outer continental shelf pipelines. Operators of transportation pipelines on the Outer Continental Shelf must identify on all their respective pipelines the specific...

  5. 49 CFR 195.9 - Outer continental shelf pipelines.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false Outer continental shelf pipelines. 195.9 Section... HAZARDOUS LIQUIDS BY PIPELINE General § 195.9 Outer continental shelf pipelines. Operators of transportation pipelines on the Outer Continental Shelf must identify on all their respective pipelines the specific...

  6. 49 CFR 195.9 - Outer continental shelf pipelines.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 3 2011-10-01 2011-10-01 false Outer continental shelf pipelines. 195.9 Section... HAZARDOUS LIQUIDS BY PIPELINE General § 195.9 Outer continental shelf pipelines. Operators of transportation pipelines on the Outer Continental Shelf must identify on all their respective pipelines the specific...

  7. 49 CFR 195.9 - Outer continental shelf pipelines.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 3 2014-10-01 2014-10-01 false Outer continental shelf pipelines. 195.9 Section... HAZARDOUS LIQUIDS BY PIPELINE General § 195.9 Outer continental shelf pipelines. Operators of transportation pipelines on the Outer Continental Shelf must identify on all their respective pipelines the specific...

  8. Buried pipelines in large fault movements

    SciTech Connect

    Wang, L.J.; Wang, L.R.L.

    1995-12-31

    Responses of buried pipelines in large fault movements are examined based upon a non-linear cantilever beam analogy. This analogy assumes that the pipeline in a large deflection zone behaves like a cantilever beam under a transverse-concentrated shear at the inflection point with a uniformly distributed soil pressure along the entire span. The tangent modulus approach is adopted to analyze the coupled axial force-bending moment interaction on pipeline deformations in the inelastic range. The buckling load of compressive pipeline is computed by the modified Newmark`s numerical integration scheme. Parametric studies of both tensile and compressive pipeline responses to various fault movements, pipeline/fault crossing angles, soil/pipe friction angles, buried depths, pipe diameters and thickness are investigated. It is shown by the comparisons that previous findings were unconservative.

  9. Arctic ice presents unusual problems for pipelines

    SciTech Connect

    Palmer, A.C.

    1985-11-01

    Submarine pipelines in Arctic and deepwater conditions present difficult engineering problems. Much has been done to resolve the problems, and the way towards Arctic development is open, but much remains to be done. Difficult pipeline design problems occur in areas that appear relatively straightforward. In the southern basin of the North Sea, for instance, the water is quite shallow, but storms and tidal currents create moving sand, waves, intense sediment transport, and scour around pipelines and structures. Exploration drilling has already reached 2000 meters water depth, and production has reached 300 meters and pipelines will soon follow. A parallel requirement is for pipeline transportation across deep straits and channels. Some of the problems faced by the engineer in designing Arctic pipelines are discussed.

  10. Locator continuously records pipeline depth readings

    SciTech Connect

    Fedde, P.A.; Patterson, C.

    1988-08-29

    Texas Gas Transmission Corp., Owensboro, Ky., has helped develop and test a pipeline-depth locator which is accurate to +-1.5 in. for lines buried as deep as 6 ft. It also continuously records pipeline depth. Development of the instrument came in response to regulations issued by the U.S. Department of Transportation (DOT), Office of Pipeline Safety (OPS), which require pipeline companies to maintain adequate cover over their buried lines and equipment. The result is that frequent surveys must determine if construction, terracing, or land-leveling activity has removed cover from the pipelines. With the instrument, a three-man crew can survey approximately 6 miles of pipeline/10-hr. working day.

  11. The STScI HST Astrometry Pipeline

    NASA Astrophysics Data System (ADS)

    Schultz, John J.; Goldstein, Philip; Hyde, Pete; Rose, Mary Alice; Steuerman, Keneth; Baum, John; Perrine, Rick; Swade, Daryl A.

    An Astrometry Data Processing Pipeline has been developed and deployed at th e Space Telescope Science Institute (STScI). This pipeline is responsible for producing Hubble Space Telescope (HST) Astrometry Data Sets used to analyze astrometry observations and the operation of the HST Fine Guidance Sensors (FGS). Prior to the STScI Astrometry Data Processing Pipeline becoming operational, HST Astrometry Data Sets were produced by the Astrometry and Engineering Data Processing (AEDP) System at Goddard Spaceflight Center (GSFC). This paper describes the processing performed by the STScI Astrometry Pipeline and how the pipeline was designed and developed to reuse existing software components from the STScI OPUS system. OPUS is an STScI developed automated data pipeline system providing a distributed processing environment used to control and monitor applications executing in a sequential order. OPUS is described in detail in other htmladdnormallinkfoot{papers} {http://www.dpt.stsci.edu/dpt_papers/opus_bib.html}.

  12. 76 FR 43743 - Pipeline Safety: Meetings of the Technical Pipeline Safety Standards Committee and the Technical...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-07-21

    ... Safety Standards Committee and the Technical Hazardous Liquid Pipeline Safety Standards Committee AGENCY... Hazardous Liquid Pipeline Safety Standards Committee (THLPSSC) would meet on August 2-3, 2011, from 9...

  13. 76 FR 28326 - Pipeline Safety: National Pipeline Mapping System Data Submissions and Submission Dates for Gas...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-05-17

    ... Systems and Liquefied Natural Gas Annual Reports AGENCY: Pipeline and Hazardous Materials Safety... operators of gas transmission and gathering systems and Liquefied Natural Gas (LNG) facilities that they... to Pipeline and Liquefied Natural Gas Reporting Requirements'' (One Rule). This rulemaking...

  14. Experimental measurement on movement of spiral-type capsule endoscope

    PubMed Central

    Yang, Wanan; Dai, Houde; He, Yong; Qin, Fengqing

    2016-01-01

    Wireless capsule endoscope achieved great success, however, the maneuvering of wireless capsule endoscope is challenging at present. A magnetic driving instrument, including two bar magnets, a stepper motor, a motor driver, a motor controller, and a power supplier, was developed to generate rotational magnetic fields. Permanent magnet ring, magnetized as S and N poles radially and mounted spiral structure on the surface, acted as a capsule. The maximum torque passing to the capsule, rotational synchronization of capsule and motor, and the translational speed of capsule, were measured in ex vivo porcine large intestine. The experimental results illustrate that the rotational movement of the spiral-type capsule in the intestine is feasible and the cost of the magnetic driving equipment is low. As a result, the solution is promising in the future controllability. PMID:26848279

  15. Experimental measurement on movement of spiral-type capsule endoscope.

    PubMed

    Yang, Wanan; Dai, Houde; He, Yong; Qin, Fengqing

    2016-01-01

    Wireless capsule endoscope achieved great success, however, the maneuvering of wireless capsule endoscope is challenging at present. A magnetic driving instrument, including two bar magnets, a stepper motor, a motor driver, a motor controller, and a power supplier, was developed to generate rotational magnetic fields. Permanent magnet ring, magnetized as S and N poles radially and mounted spiral structure on the surface, acted as a capsule. The maximum torque passing to the capsule, rotational synchronization of capsule and motor, and the translational speed of capsule, were measured in ex vivo porcine large intestine. The experimental results illustrate that the rotational movement of the spiral-type capsule in the intestine is feasible and the cost of the magnetic driving equipment is low. As a result, the solution is promising in the future controllability.

  16. Methods for protecting subsea pipelines and installations

    SciTech Connect

    Rochelle, W.R.; Simpson, D.M.

    1981-01-01

    The hazards for subsea pipelines and installations are described. Methods currently being used to protect subsea pipelines and installations are discussed with the emphasis on various trenching methods and equipment. Technical data on progress rates for trenching and feasible depths of trench are given. Possible methods for protection against icebergs are discussed. A case for more comprehensive data on icebergs is presented. Should a pipeline become damaged, repair methods are noted.

  17. A study of pipelining in computing arrays

    NASA Technical Reports Server (NTRS)

    Jagadish, H. V.; Mathews, R. G.; Newkirk, J. A.; Kailath, T.

    1986-01-01

    Scheduling considerations in computing arrays are examined. A simple sufficient condition is developed for determining whether a computing array can be pipelined. If the array cannot be pipelined in the form given, the condition also indicates the direction in which to proceed to make it pipelineable. The overall framework and methodology take a good part of the load off the logical architect of the array, and make the translation from the logical to the physical architecture a mechanical process.

  18. Application of Model-based Prognostics to a Pneumatic Valves Testbed

    NASA Technical Reports Server (NTRS)

    Daigle, Matthew; Kulkarni, Chetan S.; Gorospe, George

    2014-01-01

    Pneumatic-actuated valves play an important role in many applications, including cryogenic propellant loading for space operations. Model-based prognostics emphasizes the importance of a model that describes the nominal and faulty behavior of a system, and how faulty behavior progresses in time, causing the end of useful life of the system. We describe the construction of a testbed consisting of a pneumatic valve that allows the injection of faulty behavior and controllable fault progression. The valve opens discretely, and is controlled through a solenoid valve. Controllable leaks of pneumatic gas in the testbed are introduced through proportional valves, allowing the testing and validation of prognostics algorithms for pneumatic valves. A new valve prognostics approach is developed that estimates fault progression and predicts remaining life based only on valve timing measurements. Simulation experiments demonstrate and validate the approach.

  19. [The scintigraphic assessment of the patients suffering from cardia achalasia, treated by pneumatic dilatation].

    PubMed

    Stan, Mărioara; Bălan, G; Rusu, Maria; Ciortescu, Irina; Popa, Florentina

    2002-01-01

    The esophageal scintigraphy is a technique used to evaluate the motility and the clearance of the esophagus. The patients with achalasia of the cardia were evaluated, before treating them with pneumatic dilatation and after. The reason is to evaluate the efficiency of the pneumatic dilatation technique in the treatment of esophageal achalasia. The pneumatic dilatation with an instrument type Rigiflex is a well/handled and used technique in our clinic. In the study 22 patients were included and we had in view the esophageal transit time and the residuary radioactivity before and after the pneumatic dilatation. We established an important statistical improvement of the data obtained after the dilatation comparative with the data before the treatment (p < 0.01).

  20. An investigation of the effects of pneumatic actuator design on slip control for heavy vehicles

    NASA Astrophysics Data System (ADS)

    Miller, Jonathan I.; Cebon, David

    2013-01-01

    Progress in reducing actuator delays in pneumatic brake systems is opening the door for advanced anti-lock braking algorithms to be used on heavy goods vehicles. However, little has been published on slip controllers for air-braked heavy vehicles, or the effects of slow pneumatic actuation on their design and performance. This paper introduces a sliding mode slip controller for air-braked heavy vehicles. The effects of pneumatic actuator delays and flow rates on stopping performance and air (energy) consumption are presented through vehicle simulations. Finally, the simulations are validated with experiments using a hardware-in-the-loop rig. It is shown that for each wheel, pneumatic valves with delays smaller than 3 ms and orifice diameters around 8 mm provide the best performance.

  1. Pattern design of a non-pneumatic tyre for stiffness using topology optimization

    NASA Astrophysics Data System (ADS)

    Gwun Jang, In; Sung, Young Hwa; Jong Yoo, Eui; Kwak, Byung Man

    2012-02-01

    Non-pneumatic tyres have been developed and are being investigated, but are not very prevalent. Many design studies are still needed from the viewpoint of material, pattern, and structures. However, no systematic research for such important design issues has been reported in the literature up to now. In this article, topology optimization was utilized to determine optimal topological patterns of non-pneumatic tyres in the design process, with the goal of matching the static stiffness of the current pneumatic tyres. Under this optimization formulation with weighted compliance and a volume constraint, several different patterns were obtained depending on the number of sections, volume fraction, and weighting factors. Among them, three representative patterns were chosen and analysed for possible applications under working conditions. This article proposes a systematic and efficient tool for designing the topological patterns of non-pneumatic tyres.

  2. GLAST (FERMI) Data-Processing Pipeline

    SciTech Connect

    Flath, Daniel L.; Johnson, Tony S.; Turri, Massimiliano; Heidenreich, Karen A.; /SLAC

    2011-08-12

    The Data Processing Pipeline ('Pipeline') has been developed for the Gamma-Ray Large Area Space Telescope (GLAST) which launched June 11, 2008. It generically processes graphs of dependent tasks, maintaining a full record of its state, history and data products. The Pipeline is used to automatically process the data down-linked from the satellite and to deliver science products to the GLAST collaboration and the Science Support Center and has been in continuous use since launch with great success. The pipeline handles up to 2000 concurrent jobs and in reconstructing science data produces approximately 750GB of data products using 1/2 CPU-year of processing time per day.

  3. Aboveground pipeline response to random ground motion

    SciTech Connect

    Banerji, P.; Ghosh, A.

    1995-12-31

    Response of two types of aboveground pipelines--rigid, segmented pipelines, and flexible, continuous pipelines--to random ground motion are studied in this paper. The emphasis is on studying the effect of pipeline system parameters on its response. It is seen that pipe parameters, except for the pipe span, affect system response negligibly. Pier height and flexibility, and foundation-soil flexibility, however, affect response significantly. Furthermore, for practical situations, pipe and pier responses are decoupled, and the pier, therefore, behaves essentially as a point structure that is not affected by spatial variation of ground motion.

  4. Acoustic system for communication in pipelines

    DOEpatents

    Martin, II, Louis Peter; Cooper, John F.

    2008-09-09

    A system for communication in a pipe, or pipeline, or network of pipes containing a fluid. The system includes an encoding and transmitting sub-system connected to the pipe, or pipeline, or network of pipes that transmits a signal in the frequency range of 3-100 kHz into the pipe, or pipeline, or network of pipes containing a fluid, and a receiver and processor sub-system connected to the pipe, or pipeline, or network of pipes containing a fluid that receives said signal and uses said signal for a desired application.

  5. Costs and benefits of pneumatic collection in three specific New York City cases

    SciTech Connect

    Miller, Benjamin; Spertus, Juliette; Kamga, Camille

    2014-11-15

    Highlights: • Pneumatic and truck collection were compared in three New York City locations. • Relative costs, energy use, and greenhouse gas emissions varied significantly. • Variations were due to location-specific factors (e.g., route density, truck type). • Under appropriate conditions, pneumatic collection reduces TMT, BTU, and GHG. • Pneumatic capex may be offset by operating savings and externality benefits. - Abstract: Truck-based collection of municipal solid waste imposes significant negative externalities on cities and constrains the efficiency of separate collection of recyclables and organics and of unit-price-based waste-reduction systems. In recent decades, hundreds of municipal-scale pneumatic collection systems have been installed in Europe and Asia. Relatively few prior studies have compared the economic or environmental impacts of these systems to those of truck collection. A critical factor to consider when making this comparison is the extent to which the findings reflect the specific geographic, demographic, and operational characteristics of the systems considered. This paper is based on three case studies that consider the specific characteristics of three locations, comparing pneumatic systems with conventional collection on the basis of actual waste tonnages, composition, sources, collection routes, truck trips, and facility locations. In one case, alternative upgrades to an existing pneumatic system are compared to a potential truck-collection operation. In the other cases, existing truck operations are compared to proposed pneumatic systems which, to reduce capital costs, would be installed without new trenching or tunneling through the use of existing linear infrastructure. For the two proposed retrofit pneumatic systems, up to 48,000 truck kilometers travelled would be avoided and energy use would be reduced by up to 60% at an incremental cost of up to $400,000 USD per year over the total operating-plus-capital cost of

  6. 77 FR 16471 - Pipeline Safety: Implementation of the National Registry of Pipeline and Liquefied Natural Gas...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-03-21

    ...: Implementation of the National Registry of Pipeline and Liquefied Natural Gas Operators AGENCY: Pipeline and... registry of pipeline and liquefied natural gas operators. This notice provides updates to the information... and liquefied natural gas (LNG) operators. New operators use the national registry to obtain...

  7. Experimental study on wavy-flow pneumatic conveying in horizontal pipe

    NASA Astrophysics Data System (ADS)

    Xu, Hua; Liu, Shi; Wang, Haigang; Jiang, Fan

    2002-05-01

    Low-velocity pneumatic conveying systems have been developed to meet the requirement of low operation costs and have been widely used in chemical and process industries. However, the understanding of the mechanism is limited. This paper reports an experimental study on a slug-flow pneumatic conveying. Electrical capacitance tomography has been used to visualize plug shape and identify the flow pattern. Comparison was made between the experimental data of pressure drop with existed models.

  8. Costs and benefits of pneumatic collection in three specific New York City cases.

    PubMed

    Miller, Benjamin; Spertus, Juliette; Kamga, Camille

    2014-11-01

    Truck-based collection of municipal solid waste imposes significant negative externalities on cities and constrains the efficiency of separate collection of recyclables and organics and of unit-price-based waste-reduction systems. In recent decades, hundreds of municipal-scale pneumatic collection systems have been installed in Europe and Asia. Relatively few prior studies have compared the economic or environmental impacts of these systems to those of truck collection. A critical factor to consider when making this comparison is the extent to which the findings reflect the specific geographic, demographic, and operational characteristics of the systems considered. This paper is based on three case studies that consider the specific characteristics of three locations, comparing pneumatic systems with conventional collection on the basis of actual waste tonnages, composition, sources, collection routes, truck trips, and facility locations. In one case, alternative upgrades to an existing pneumatic system are compared to a potential truck-collection operation. In the other cases, existing truck operations are compared to proposed pneumatic systems which, to reduce capital costs, would be installed without new trenching or tunneling through the use of existing linear infrastructure. For the two proposed retrofit pneumatic systems, up to 48,000 truck kilometers travelled would be avoided and energy use would be reduced by up to 60% at an incremental cost of up to $400,000 USD per year over the total operating-plus-capital cost of conventional collection. In the location where a greenfield pneumatic system is already in operation, truck collection would be both less expensive and more energy-efficient than pneumatic collection. The results demonstrate that local geographic, demographic, and operational conditions play a decisive role in determining whether pneumatic collection will reduce energy requirements, produce more or fewer greenhouse gas emissions, and cost more

  9. Intermittent pneumatic compression of legs increases microcirculation in distant skeletal muscle.

    PubMed

    Liu, K; Chen, L E; Seaber, A V; Johnson, G W; Urbaniak, J R

    1999-01-01

    Intermittent pneumatic compression has been established as a method of clinically preventing deep vein thrombosis, but the mechanism has not been documented. This study observed the effects of intermittent pneumatic compression of legs on the microcirculation of distant skeletal muscle. The cremaster muscles of 80 male rats were exposed, a specially designed intermittent pneumatic-compression device was applied to both legs for 60 minutes, and the microcirculation of the muscles was assessed by measurement of the vessel diameter in three categories (10-20, 21-40, and 41-70 microm) for 120 minutes. The results showed significant vasodilation in arterial and venous vessels during the application of intermittent pneumatic compression, which disappeared after termination of the compression. The vasodilation reached a maximum 30 minutes after initiation of the compression and could be completely blocked by an inhibitor of nitric oxide synthase, NG-monomethyl-L-arginine (10 micromol/min). A 120-minute infusion of NG-monomethyl-L-arginine, beginning coincident with 60 minutes of intermittent pneumatic compression, resulted in a significant decrease in arterial diameter that remained at almost the same level after termination of the compression. The magnitude of the decrease in diameter in the group treated with intermittent pneumatic compression and NG-monomethyl-L-arginine was comparable with that in the group treated with NG-monomethyl-L-arginine alone. The results imply that the production of nitric oxide is involved in the positive influence of intermittent pneumatic compression on circulation. It is postulated that the rapid increase in venous velocity induced by intermittent pneumatic compression produces strong shear stress on the vascular endothelium, which stimulates an increased release of nitric oxide and thereby causes systemic vasodilation.

  10. Field and numerical determinations of pneumatic flow parameters of unsaturated fractured porous rocks on various scales

    NASA Astrophysics Data System (ADS)

    Guillon, S.; Vu, M. T.; Pili, E.; Adler, P. M.

    2013-05-01

    Air permeability is measured in the fractured crystalline rocks of the Roselend Natural Laboratory (France). Single-hole pneumatic injection tests as well as differential barometric pressure monitoring are conducted on scales ranging from 1 to 50 m, in both shallow and deep boreholes, as well as in an isolated 60 m3 chamber at 55 m depth. The field experiments are interpreted using numerical simulations in equivalent homogeneous porous media with their real 3-D geometry in order to estimate pneumatic parameters. For pneumatic injection tests, steady-state data first allow to estimate air permeability. Then, pressure recovery after a pneumatic injection test allows to estimate the air-filled porosity. Comparison between the various studied cases clarifies the influence of the boundary conditions on the accuracy of the often used 1-D estimate of air permeability. It also shows that permeabilities correlate slightly with fracture density. In the chamber, a 1 order-of-magnitude difference is found between the air permeabilities obtained from pneumatic injection tests and from differential barometric pressure monitoring. This discrepancy is interpreted as a scale effect resulting from the approximation of the heterogeneous fractured rock by a homogeneous numerical model. The difference between the rock volumes investigated by pneumatic injection tests and by differential barometric pressure monitoring may also play a role. No clear dependence of air permeability on saturation has been found so far.

  11. [The forensic medical characteristics of the entrance bullet holes created by the shots from pneumatic rifles].

    PubMed

    Legin, G A; Bondarchuk, A O; Perebetiuk, A N

    2015-01-01

    The objective of the present study was to compare the injurious action of three types of the bullets for the pneumatic weapons shot from different distances using the Gamo pump air pistol and the BAM B22-1 pneumatic rifle. The following four kinds of the bullets were tested: "the fireball", "Luman cap 0.3", "Luman Field Target 0.68" and "DIABOLO". It was experimentally shown that the injurious action of the bullets fired from the same distance from the pneumatic weapons depends on the type of both the bullet and the weapon, as well as the properties of the target material. Specifically, the action of bullets fired from the piston pneumatic rifle remained stable whereas that of the bullets shot from the gas-balloon air pistol decreased as the gas was exhausted. The studies by the contact-diffusion method have demonstrated that the entrance bullet holes created by the shots from pneumatic weapons are surrounded by dispersed metal particles which makes it possible to estimate the shooting distance. Moreover, the bullets fired from the pneumatic weapons leave the muzzle face imprint on certain target materials.

  12. Antibody immobilization using pneumatic spray: comparison with the avidin-biotin bridge immobilization method.

    PubMed

    Figueroa, Jhon; Magaña, Sonia; Lim, Daniel V; Schlaf, Rudy

    2012-12-14

    The formation of a thin antibody film on a glass surface using pneumatic spray was investigated as a potential immobilization technique for capturing pathogenic targets. Goat-Escherichia coli O157:H7 IgG films were made by pneumatic spray and compared against the avidin-biotin bridge immobilized films by assaying with green fluorescent protein (GFP) transformed E. coli O157:H7 cells and fluorescent reporter antibodies. Functionality, stability, and immobilization of the films were tested. The pneumatic spray films had lower fluorescence intensity values than the avidin-biotin bridge films but resulted in similar detection for E. coli O157:H7 at 10(5)-10(7)cells/ml sample concentrations with no detection of non-E. coli O157:H7 strains. Both methods also resulted in similar percent capture efficiencies. The results demonstrated that immobilization of antibody via pneumatic spray did not render the antibody non-functional and produced stable antibody films. The amount of time necessary for immobilization of the antibody was reduced significantly from 24h for the avidin-biotin bridge to 7 min using the pneumatic spray technique, with additional benefits of greatly reduced use of materials and chemicals. The pneumatic spray technique promises to be an alternative for the immobilization of antibodies on glass slides for capturing pathogenic targets and use in biosensor type devices.

  13. Pneumatic motor powered Thrust Vector Control (TVC) for liquid propelled launch vehicles

    NASA Astrophysics Data System (ADS)

    Malone, Mark C.; Evans, P. S.

    1992-02-01

    Recent studies performed for the Titan 4 launch vehicle indicate significant potential advantages in replacing the current stage 1 and 2 recirculating hydraulic TVC (thrust vector control) system with a PMA (pneumatic mechanical actuation) system. Some of the advantages of a PMA system over the recirculating hydraulic system include reduced part count and weight, reduced maintenance and life-cycle cost, and improved mission reliability. PMA technology, used in aircraft applications since the 1960s, is well suited in launch vehicle TVC applications where an existing pneumatic pressure source is available. A typical pneumatic motor TVC consists of a pneumatic power source, a dual rotor pneumatic motor, a gear box, a ball screw actuator, and the associated closed-loop servo-control elements. One key issue with implementing this mechanical approach is designing a TVC system to withstand large load transient disturbances during liquid engine starting. Hydraulic actuator transient loads have exceeded 60,000 lb(sub f) for a 30,000 lb(sub f) stall design actuator during ground starts of the Titan 3B, Stage 1 engine. A PMA TVC system must also withstand these start transients without imparting excessive reaction loads to the engine nozzle and thrust structure. Work completed to date with Martin Marietta to examine pneumatic motor powered TVC options and technology benefits is presented. The load transient issue is discussed along with potential solutions and the associated trades. General background on PMA technology and experience base is also presented.

  14. 75 FR 4610 - Pipeline Safety: Information Collection Activities

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-01-28

    ... Pipeline and Hazardous Materials Safety Administration Pipeline Safety: Information Collection Activities AGENCY: Pipeline and Hazardous Materials Safety Administration. ACTION: Notice and request for comments... Hazardous Materials Safety Administration (PHMSA) published a notice in the Federal Register (74 FR...

  15. 77 FR 46155 - Pipeline Safety: Information Collection Activities

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-08-02

    ...] [FR Doc No: 2012-18861] DEPARTMENT OF TRANSPORTATION Pipeline and Hazardous Materials Safety Administration [Docket No. PHMSA-2012-0094] Pipeline Safety: Information Collection Activities AGENCY: Pipeline and Hazardous Materials Safety Administration (PHMSA), DOT. ACTION: Notice and request for...

  16. 77 FR 27279 - Pipeline Safety: Information Collection Activities

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-05-09

    ... From the Federal Register Online via the Government Publishing Office ] DEPARTMENT OF TRANSPORTATION Pipeline and Hazardous Materials Safety Administration Pipeline Safety: Information Collection Activities AGENCY: Pipeline and Hazardous Materials Safety Administration (PHMSA), DOT. ACTION: Notice...

  17. 18 CFR 284.227 - Certain transportation by intrastate pipelines.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... Interstate Pipelines on Behalf of Others and Services by Local Distribution Companies § 284.227 Certain... interstate pipeline or local distribution company served by an interstate pipeline. (e) Pregrant...

  18. 77 FR 74276 - Pipeline Safety: Information Collection Activities

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-12-13

    ..., titled ``Integrity Management in High Consequence Areas for Operators of Hazardous Liquid Pipelines..., titled: ``Integrity Management in High Consequence Areas for Operators of Hazardous Liquid Pipelines... Management in High Consequence Areas for Operators of Hazardous Liquid Pipelines. OMB Control Number:...

  19. 78 FR 16764 - Pipeline Safety: Information Collection Activities

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-03-18

    ... From the Federal Register Online via the Government Publishing Office DEPARTMENT OF TRANSPORTATION Pipeline and Hazardous Materials Safety Administration Pipeline Safety: Information Collection Activities AGENCY: Pipeline and Hazardous Materials Safety Administration (PHMSA), DOT. ACTION: Notice and...

  20. 76 FR 70217 - Pipeline Safety: Information Collection Activities

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-11-10

    ... Pipeline and Hazardous Materials Administration Pipeline Safety: Information Collection Activities ACTION... Act of 1995, the Pipeline and Hazardous Materials Safety Administration (PHMSA) published a notice in... Hazardous Materials Safety Administration, 1200 New Jersey Avenue SE., PHP-30, Washington, DC...

  1. 77 FR 34457 - Pipeline Safety: Mechanical Fitting Failure Reports

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-06-11

    ... From the Federal Register Online via the Government Publishing Office DEPARTMENT OF TRANSPORTATION Pipeline and Hazardous Materials Safety Administration Pipeline Safety: Mechanical Fitting Failure Reports AGENCY: Pipeline and Hazardous Materials Safety Administration (PHMSA), DOT. ACTION: Notice; Issuance...

  2. 77 FR 34458 - Pipeline Safety: Requests for Special Permit

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-06-11

    ... From the Federal Register Online via the Government Publishing Office DEPARTMENT OF TRANSPORTATION Pipeline and Hazardous Materials Safety Administration Pipeline Safety: Requests for Special Permit AGENCY: Pipeline and Hazardous Materials Safety Administration (PHMSA); DOT. ACTION: Notice. SUMMARY: Pursuant...

  3. 77 FR 26822 - Pipeline Safety: Verification of Records

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-05-07

    ... Pipeline and Hazardous Materials Safety Administration Pipeline Safety: Verification of Records AGENCY: Pipeline and Hazardous Materials Safety Administration (PHMSA), DOT. ACTION: Notice; Issuance of Advisory... Special Programs Administration and the Materials Transportation Bureau, PHMSA's predecessor...

  4. 78 FR 59906 - Pipeline Safety: Class Location Requirements

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-09-30

    ... Pipeline and Hazardous Materials Safety Administration 49 CFR Part 192 Pipeline Safety: Class Location... Register on ``Class Location Requirements,'' seeking comments on whether integrity management program (IMP... gas transmission pipeline facilities, whether applying IMP requirements to additional areas...

  5. 75 FR 67807 - Pipeline Safety: Emergency Preparedness Communications

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-11-03

    ... Communications AGENCY: Pipeline and Hazardous Materials Safety Administration (PHMSA); DOT. ACTION: Notice... Hazardous Liquid and Gas Pipeline Systems. Subject: Emergency Preparedness Communications. Advisory: To... preparedness communications between pipeline operators and emergency responders. To ensure a prompt,...

  6. 78 FR 24309 - Pipeline and Hazardous Materials Safety Administration

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-04-24

    ... Pipeline and Hazardous Materials Safety Administration List of Special Permit Applications Delayed AGENCY: Pipeline and Hazardous Materials Safety Administration (PHMSA), DOT. ACTION: List of Applications Delayed... of Hazardous Materials Special Permits and Approvals, Pipeline and Hazardous Materials...

  7. 77 FR 58623 - Pipeline Safety: Request for Special Permit

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-09-21

    ... From the Federal Register Online via the Government Publishing Office DEPARTMENT OF TRANSPORTATION Pipeline and Hazardous Materials Safety Administration Pipeline Safety: Request for Special Permit AGENCY: Pipeline and Hazardous Materials Safety Administration (PHMSA); DOT. ACTION: Notice. SUMMARY: Pursuant...

  8. 78 FR 23972 - Pipeline Safety: Information Collection Activities

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-04-23

    ... From the Federal Register Online via the Government Publishing Office DEPARTMENT OF TRANSPORTATION Pipeline and Hazardous Materials Safety Administration Pipeline Safety: Information Collection Activities AGENCY: Pipeline and Hazardous Materials Safety Administration (PHMSA), DOT. ACTION: Notice and...

  9. Capsule- and disk-filter procedure

    USGS Publications Warehouse

    Skrobialowski, Stanley C.

    2016-01-01

    Capsule and disk filters are disposable, self-contained units composed of a pleated or woven filter medium encased in a polypropylene or other plastic housing that can be connected inline to a sample-delivery system (such as a submersible or peristaltic pump) that generates sufficient pressure (positive or negative) to force water through the filter. Filter media are available in several pore sizes, but 0.45 µm is the pore size used routinely for most studies at this time. Capsule or disk filters (table 5.2.1.A.1) are required routinely for most studies when filtering samples for trace-element analyses and are recommended when filtering samples for major-ion or other inorganic-constituent analyses.

  10. Electroformation of Janus and patchy capsules

    PubMed Central

    Rozynek, Zbigniew; Mikkelsen, Alexander; Dommersnes, Paul; Fossum, Jon Otto

    2014-01-01

    Janus and patchy particles have designed heterogeneous surfaces that consist of two or several patches with different materials properties. These particles are emerging as building blocks for a new class of soft matter and functional materials. Here we introduce a route for forming heterogeneous capsules by producing highly ordered jammed colloidal shells of various shapes with domains of controlled size and composition. These structures combine the functionalities offered by Janus or patchy particles, and those given by permeable shells such as colloidosomes. The simple assembly route involves the synergetic action of electro-hydrodynamic flow and electro-coalescence. We demonstrate that the method is robust and straightforwardly extendable to production of multi-patchy capsules. This forms a starting point for producing patchy colloidosomes with domains of anisotropic chemical surface properties, permeability or mixed liquid–solid phase domains, which could be exploited to produce functional emulsions, light and hollow supra-colloidosome structures, or scaffolds. PMID:24853057

  11. Adhesive capsulitis of the hip: a review.

    PubMed

    Looney, Colin G; Raynor, Brett; Lowe, Rebecca

    2013-12-01

    Adhesive capsulitis of the hip (ACH) is a rare clinical entity. Similar to adhesive capsulitis of the shoulder, ACH is characterized by a painful decrease in active and passive range of motion as synovial inflammation in the acute stages of the disease progresses to capsular fibrosis in the chronic stages. Once other diagnoses have been ruled out, management of ACH is tailored to reduce inflammation in the acute stages with NSAIDs, intra-articular steroid injections, and targeted physical therapy while biomechanical dysfunction in the spine, hip, sacroiliac joint, or lower limb joints is addressed. In chronic stages of the disease, intervention should focus on decreasing the progression of fibrotic changes and regaining range of motion through aggressive physical therapy. Interventions described for chronic ACH include manipulation under anesthesia; pressure dilatation; and open or arthroscopic synovectomy, lysis of adhesions, and capsular release. Surgical intervention should be considered only after failure of a minimum 3-month course of nonsurgical treatment.

  12. Addressing the workforce pipeline challenge

    SciTech Connect

    Leonard Bond; Kevin Kostelnik; Richard Holman

    2006-11-01

    A secure and affordable energy supply is essential for achieving U.S. national security, in continuing U.S. prosperity and in laying the foundations to enable future economic growth. To meet this goal the next generation energy workforce in the U.S., in particular those needed to support instrumentation, controls and advanced operations and maintenance, is a critical element. The workforce is aging and a new workforce pipeline, to support both current generation and new build has yet to be established. The paper reviews the challenges and some actions being taken to address this need.

  13. [Quality control of zhuanggu shenjin capsules].

    PubMed

    Ni, G; Chen, X; Zhang, Y; Liu, Z; Gao, Y; Quan, R; Sun, Q; Ni, H

    1996-01-01

    Studies have been made on the microscopic identification of red jinseng, dog bone, indian bread, yanhusuo and datura flower in Zhuanggu Shenjin Capsules, as well as on the identification of ginsengside and tetrahydropalmatine by TLC and the determination of icariin by dual wavelength TLC-scanning. The content of the latter compound should be no less than 0.380mg/g and the average rate of recovery 97.62% (n = 5).

  14. Rarefied Flows of Planetary Entry Capsules

    NASA Technical Reports Server (NTRS)

    Moss, James N.

    1997-01-01

    The impact of rarefaction on entry capsules and spacecraft aerothermodynamics is emphasized for various aeroassist missions. The capability of the direct simulation Monte Carlo (DSMC) method to simulate such flows is demonstrated through examples of validation studies and applications. Several space flight projects and ground-based experiments are reviewed for which rarefaction effects have significant effect on spacecraft performance or experimental measurements. This review clearly demonstrates the significant role that the DSMC method plays in characterizing such flows.

  15. Analysis of 2011 Defect Imaging Capsule Implosions

    NASA Astrophysics Data System (ADS)

    Bradley, Paul; Cobble, James; Hsu, Scott; Magelssen, Glenn; Murphy, Thomas; Obery, Kimberly; Schmitt, Mark; Tregillis, Ian; Krasheninnikova, Natalia; Wysocki, Frederick

    2011-10-01

    Los Alamos is engaged in a project to design high neutron fluence feature-driven mix experiments for the National Ignition Facility in 2012. These results will be relevant for determining how much imperfection capsules can have in inertial fusion energy. To prepare for NIF, we fielded shots on the Omega laser in January and July 2011 with a 40 beam polar direct drive configuration similar to what we will employ on NIF. The capsules were 15 to 17 micron CH plastic shells about 880 microns in diameter filled with 5 atm of D2 gas. We fielded capsules with different dopant layers and different depth equatorial grooves that were about 30 microns wide. We obtained radius versus time plots, radiographs, neutron yields, ion temperatures, burn widths, streak spectra, among other data. Preliminary calculations show that we match the radius versus time plots within about the data error and we have reasonable matches to the other data. We will will present these results and additional detailed comparisons of calculations to data. Work performed by Los Alamos National Laboratory under contract DE-AC52-06NA25396 for the National Nuclear Security Administration of the U.S. Department of Energy.

  16. Aerodynamics for the Mars Phoenix Entry Capsule

    NASA Technical Reports Server (NTRS)

    Edquist, Karl T.; Desai, Prasun N.; Schoenenberger, Mark

    2008-01-01

    Pre-flight aerodynamics data for the Mars Phoenix entry capsule are presented. The aerodynamic coefficients were generated as a function of total angle-of-attack and either Knudsen number, velocity, or Mach number, depending on the flight regime. The database was constructed using continuum flowfield computations and data from the Mars Exploration Rover and Viking programs. Hypersonic and supersonic static coefficients were derived from Navier-Stokes solutions on a pre-flight design trajectory. High-altitude data (free-molecular and transitional regimes) and dynamic pitch damping characteristics were taken from Mars Exploration Rover analysis and testing. Transonic static coefficients from Viking wind tunnel tests were used for capsule aerodynamics under the parachute. Static instabilities were predicted at two points along the reference trajectory and were verified by reconstructed flight data. During the hypersonic instability, the capsule was predicted to trim at angles as high as 2.5 deg with an on-axis center-of-gravity. Trim angles were predicted for off-nominal pitching moment (4.2 deg peak) and a 5 mm off-axis center-ofgravity (4.8 deg peak). Finally, hypersonic static coefficient sensitivities to atmospheric density were predicted to be within uncertainty bounds.

  17. Capsule Design for Hybrid Shock Ignition

    NASA Astrophysics Data System (ADS)

    Baumgaertel, J. A.; Dodd, E. S.; Loomis, E. N.

    2014-10-01

    Hybrid Shock-Ignition (HSI) is an alternate fusion energy concept that combines indirect drive and shock ignition schemes in order to access new regimes in National Ignition Facility (NIF) hohlraum physics. Building off of tetrahedral hohlraum experiments at the OMEGA laser facility, we have preliminary designs for spherical hohlraums that combine symmetrically arranged laser entrance holes for indirect-drive beams (to initially compress the capsule) and holes for direct-drive beams to drive a strong ignitor shock (to further compress and ignite the fuel). A LANL Eulerian hydrodynamic code is being used to find optimal laser drive, hohlraum, and capsule specifications, via criteria such as implosion symmetry, implosion time, and neutron yield. At first, drive will be modeled using a radiation source to mimic the hohlraum drive, and later, ignitor beams will be added. Initial capsule designs will be presented for experiments to develop the HSI platform on the sub-ignition scale OMEGA laser facility in FY15. Supported under the U.S. Department of Energy by the Los Alamos National Security, LLC under Contract DE-AC52-06NA25396. LA-UR-14-25071.

  18. Basic ammonothermal GaN growth in molybdenum capsules

    NASA Astrophysics Data System (ADS)

    Pimputkar, S.; Speck, J. S.; Nakamura, S.

    2016-12-01

    Single crystal, bulk gallium nitride (GaN) crystals were grown using the basic ammonothermal method in a high purity growth environment created using a non-hermetically sealed molybdenum (Mo) capsule and compared to growths performed in a similarly designed silver (Ag) capsule and capsule-free René 41 autoclave. Secondary ion mass spectrometry (SIMS) analysis revealed transition metal free (<1×1017 cm-3) GaN crystals. Anomalously low oxygen concentrations ((2-6)×1018 cm-3) were measured in a {0001} seeded crystal boule grown using a Mo capsule, despite higher source material oxygen concentrations ((1-5)×1019 cm-3) suggesting that molybdenum (or molybdenum nitrides) may act to getter oxygen under certain conditions. Total system pressure profiles from growth runs in a Mo capsule system were comparable to those without a capsule, with pressures peaking within 2 days and slowly decaying due to hydrogen diffusional losses. Measured Mo capsule GaN growth rates were comparable to un-optimized growth rates in capsule-free systems and appreciably slower than in Ag-capsule systems. Crystal quality replicated that of the GaN seed crystals for all capsule conditions, with high quality growth occurring on the (0001) Ga-face. Optical absorption and impurity concentration characterization suggests reduced concentrations of hydrogenated gallium vacancies (VGa-Hx).

  19. High-speed precision weighing of pharmaceutical capsules

    NASA Astrophysics Data System (ADS)

    Bürmen, Miran; Pernuš, Franjo; Likar, Boštjan

    2009-11-01

    In this paper, we present a cost-effective method for fast and accurate in-line weighing of hard gelatin capsules based on the optimized capacitance sensor and real-time processing of the capsule capacitance profile resulting from 5000 capacitance measurements per second. First, the effect of the shape and size of the capacitive sensor on the sensitivity and stability of the measurements was investigated in order to optimize the performance of the system. The method was tested on two types of hard gelatin capsules weighing from 50 mg to 650 mg. The results showed that the capacitance profile was exceptionally well correlated with the capsule weight with the correlation coefficient exceeding 0.999. The mean precision of the measurements was in the range from 1 mg to 3 mg, depending on the size of the capsule and was significantly lower than the 5% weight tolerances usually used by the pharmaceutical industry. Therefore, the method was found feasible for weighing pharmaceutical hard gelatin capsules as long as certain conditions are met regarding the capsule fill properties and environment stability. The proposed measurement system can be calibrated by using only two or three sets of capsules with known weight. However, for most applications it is sufficient to use only empty and nominally filled capsules for calibration. Finally, a practical application of the proposed method showed that a single system is capable of weighing around 75 000 capsules per hour, while using multiple systems could easily increase the inspection rate to meet almost any requirements.

  20. Oman-India pipeline route survey

    SciTech Connect

    Mullee, J.E.

    1995-12-01

    Paper describes the geological setting in the Arabian Sea for a proposed 28-inch gas pipeline from Oman to India reaching 3,500-m water depths. Covers planning, execution, quality control and results of geophysical, geotechnical and oceanographic surveys. Outlines theory and application of pipeline stress analysis on board survey vessel for feasibility assessment, and specifies equipment used.