Sample records for pneumatic control system

  1. Improving dynamic performances of PWM-driven servo-pneumatic systems via a novel pneumatic circuit.

    PubMed

    Taghizadeh, Mostafa; Ghaffari, Ali; Najafi, Farid

    2009-10-01

    In this paper, the effect of pneumatic circuit design on the input-output behavior of PWM-driven servo-pneumatic systems is investigated and their control performances are improved using linear controllers instead of complex and costly nonlinear ones. Generally, servo-pneumatic systems are well known for their nonlinear behavior. However, PWM-driven servo-pneumatic systems have the advantage of flexibility in the design of pneumatic circuits which affects the input-output linearity of the whole system. A simple pneumatic circuit with only one fast switching valve is designed which leads to a quasi-linear input-output relation. The quasi-linear behavior of the proposed circuit is verified both experimentally and by simulations. Closed loop position control experiments are then carried out using linear P- and PD-controllers. Since the output position is noisy and cannot be directly differentiated, a Kalman filter is designed to estimate the velocity of the cylinder. Highly improved tracking performances are obtained using these linear controllers, compared to previous works with nonlinear controllers.

  2. A Novel Real-Time Path Servo Control of a Hardware-in-the-Loop for a Large-Stroke Asymmetric Rod-Less Pneumatic System under Variable Loads.

    PubMed

    Lin, Hao-Ting

    2017-06-04

    This project aims to develop a novel large stroke asymmetric pneumatic servo system of a hardware-in-the-loop for path tracking control under variable loads based on the MATLAB Simulink real-time system. High pressure compressed air provided by the air compressor is utilized for the pneumatic proportional servo valve to drive the large stroke asymmetric rod-less pneumatic actuator. Due to the pressure differences between two chambers, the pneumatic actuator will operate. The highly nonlinear mathematical models of the large stroke asymmetric pneumatic system were analyzed and developed. The functional approximation technique based on the sliding mode controller (FASC) is developed as a controller to solve the uncertain time-varying nonlinear system. The MATLAB Simulink real-time system was a main control unit of a hardware-in-the-loop system proposed to establish driver blocks for analog and digital I/O, a linear encoder, a CPU and a large stroke asymmetric pneumatic rod-less system. By the position sensor, the position signals of the cylinder will be measured immediately. The measured signals will be viewed as the feedback signals of the pneumatic servo system for the study of real-time positioning control and path tracking control. Finally, real-time control of a large stroke asymmetric pneumatic servo system with measuring system, a large stroke asymmetric pneumatic servo system, data acquisition system and the control strategy software will be implemented. Thus, upgrading the high position precision and the trajectory tracking performance of the large stroke asymmetric pneumatic servo system will be realized to promote the high position precision and path tracking capability. Experimental results show that fifth order paths in various strokes and the sine wave path are successfully implemented in the test rig. Also, results of variable loads under the different angle were implemented experimentally.

  3. A Novel Real-Time Path Servo Control of a Hardware-in-the-Loop for a Large-Stroke Asymmetric Rod-Less Pneumatic System under Variable Loads

    PubMed Central

    Lin, Hao-Ting

    2017-01-01

    This project aims to develop a novel large stroke asymmetric pneumatic servo system of a hardware-in-the-loop for path tracking control under variable loads based on the MATLAB Simulink real-time system. High pressure compressed air provided by the air compressor is utilized for the pneumatic proportional servo valve to drive the large stroke asymmetric rod-less pneumatic actuator. Due to the pressure differences between two chambers, the pneumatic actuator will operate. The highly nonlinear mathematical models of the large stroke asymmetric pneumatic system were analyzed and developed. The functional approximation technique based on the sliding mode controller (FASC) is developed as a controller to solve the uncertain time-varying nonlinear system. The MATLAB Simulink real-time system was a main control unit of a hardware-in-the-loop system proposed to establish driver blocks for analog and digital I/O, a linear encoder, a CPU and a large stroke asymmetric pneumatic rod-less system. By the position sensor, the position signals of the cylinder will be measured immediately. The measured signals will be viewed as the feedback signals of the pneumatic servo system for the study of real-time positioning control and path tracking control. Finally, real-time control of a large stroke asymmetric pneumatic servo system with measuring system, a large stroke asymmetric pneumatic servo system, data acquisition system and the control strategy software will be implemented. Thus, upgrading the high position precision and the trajectory tracking performance of the large stroke asymmetric pneumatic servo system will be realized to promote the high position precision and path tracking capability. Experimental results show that fifth order paths in various strokes and the sine wave path are successfully implemented in the test rig. Also, results of variable loads under the different angle were implemented experimentally. PMID:28587220

  4. Pneumatic Valve Operated by Multiplex Pneumatic Transmission

    NASA Astrophysics Data System (ADS)

    Nishioka, Yasutaka; Suzumori, Koichi; Kanda, Takefumi; Wakimoto, Shuichi

    A pneumatic system has several advantages, which are cheapness, lightweight, and reliability to human and environment. These advantages are adapted to some research areas, such as industrial lines, medical and nursing cares, and rehabilitation tools. However, the pneumatic system needs several devices; compressor, air tube, and control valve. This research aim to downsize pneumatic system. In this paper, a new method of multiplex pneumatic transmission for multi-pneumatic servo system is proposed. The valve for this system consists of two vibrators supported by springs, which was designed with simple and cheap structure. The working principle of the valve is vibrators resonance from multiplex pneumatic transmission and it is possible to work as ON/OFF valves without electric wire. Dynamic simulation was used to confirm the working principle of the resonance driving system. A prototype device confirming the principle was designed and developed based on the simulation. The experiments show that this new control system works very well to control two separated valves through single pneumatic tube.

  5. Experimental research of flow servo-valve

    NASA Astrophysics Data System (ADS)

    Takosoglu, Jakub

    Positional control of pneumatic drives is particularly important in pneumatic systems. Some methods of positioning pneumatic cylinders for changeover and tracking control are known. Choking method is the most development-oriented and has the greatest potential. An optimal and effective method, particularly when applied to pneumatic drives, has been searched for a long time. Sophisticated control systems with algorithms utilizing artificial intelligence methods are designed therefor. In order to design the control algorithm, knowledge about real parameters of servo-valves used in control systems of electro-pneumatic servo-drives is required. The paper presents the experimental research of flow servo-valve.

  6. Development of X-Y servo pneumatic-piezoelectric hybrid actuators for position control with high response, large stroke and nanometer accuracy.

    PubMed

    Chiang, Mao-Hsiung

    2010-01-01

    This study aims to develop a X-Y dual-axial intelligent servo pneumatic-piezoelectric hybrid actuator for position control with high response, large stroke (250 mm, 200 mm) and nanometer accuracy (20 nm). In each axis, the rodless pneumatic actuator serves to position in coarse stroke and the piezoelectric actuator compensates in fine stroke. Thus, the overall control systems of the single axis become a dual-input single-output (DISO) system. Although the rodless pneumatic actuator has relatively larger friction force, it has the advantage of mechanism for multi-axial development. Thus, the X-Y dual-axial positioning system is developed based on the servo pneumatic-piezoelectric hybrid actuator. In addition, the decoupling self-organizing fuzzy sliding mode control is developed as the intelligent control strategies. Finally, the proposed novel intelligent X-Y dual-axial servo pneumatic-piezoelectric hybrid actuators are implemented and verified experimentally.

  7. Development of X-Y Servo Pneumatic-Piezoelectric Hybrid Actuators for Position Control with High Response, Large Stroke and Nanometer Accuracy

    PubMed Central

    Chiang, Mao-Hsiung

    2010-01-01

    This study aims to develop a X-Y dual-axial intelligent servo pneumatic-piezoelectric hybrid actuator for position control with high response, large stroke (250 mm, 200 mm) and nanometer accuracy (20 nm). In each axis, the rodless pneumatic actuator serves to position in coarse stroke and the piezoelectric actuator compensates in fine stroke. Thus, the overall control systems of the single axis become a dual-input single-output (DISO) system. Although the rodless pneumatic actuator has relatively larger friction force, it has the advantage of mechanism for multi-axial development. Thus, the X-Y dual-axial positioning system is developed based on the servo pneumatic-piezoelectric hybrid actuator. In addition, the decoupling self-organizing fuzzy sliding mode control is developed as the intelligent control strategies. Finally, the proposed novel intelligent X-Y dual-axial servo pneumatic-piezoelectric hybrid actuators are implemented and verified experimentally. PMID:22319266

  8. 49 CFR 236.590 - Pneumatic apparatus.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Pneumatic apparatus. 236.590 Section 236.590..., Train Control and Cab Signal Systems Inspection and Tests; Locomotive § 236.590 Pneumatic apparatus. Automatic train stop, train control, or cab signal pneumatic apparatus shall be inspected, cleaned, and the...

  9. 49 CFR 236.590 - Pneumatic apparatus.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 4 2011-10-01 2011-10-01 false Pneumatic apparatus. 236.590 Section 236.590..., Train Control and Cab Signal Systems Inspection and Tests; Locomotive § 236.590 Pneumatic apparatus. Automatic train stop, train control, or cab signal pneumatic apparatus shall be inspected, cleaned, and the...

  10. Design and Dynamic Model of a Frog-inspired Swimming Robot Powered by Pneumatic Muscles

    NASA Astrophysics Data System (ADS)

    Fan, Ji-Zhuang; Zhang, Wei; Kong, Peng-Cheng; Cai, He-Gao; Liu, Gang-Feng

    2017-09-01

    Pneumatic muscles with similar characteristics to biological muscles have been widely used in robots, and thus are promising drivers for frog inspired robots. However, the application and nonlinearity of the pneumatic system limit the advance. On the basis of the swimming mechanism of the frog, a frog-inspired robot based on pneumatic muscles is developed. To realize the independent tasks by the robot, a pneumatic system with internal chambers, micro air pump, and valves is implemented. The micro pump is used to maintain the pressure difference between the source and exhaust chambers. The pneumatic muscles are controlled by high-speed switch valves which can reduce the robot cost, volume, and mass. A dynamic model of the pneumatic system is established for the simulation to estimate the system, including the chamber, muscle, and pneumatic circuit models. The robot design is verified by the robot swimming experiments and the dynamic model is verified through the experiments and simulations of the pneumatic system. The simulation results are compared to analyze the functions of the source pressure, internal volume of the muscle, and circuit flow rate which is proved the main factor that limits the response of muscle pressure. The proposed research provides the application of the pneumatic muscles in the frog inspired robot and the pneumatic model to study muscle controller.

  11. Multistage position-stabilized vibration isolation system for neutron interferometry

    NASA Astrophysics Data System (ADS)

    Arif, Muhammad; Brown, Dennis E.; Greene, Geoffrey L.; Clothier, R.; Littrell, K.

    1994-10-01

    A two stage, position stabilized vibration isolation system has been constructed and is now in operation at the Cold Neutron Research Facility of the National Institute of Standards and Technology, Gaithersburg, MD. The system employs pneumatic isolators with a multiple input/multiple output pneumatic servo system based upon pulse width modulation control loops. The first stage consists of a 40,000 kg reinforced concrete table supported by pneumatic isolators. A large environmentally isolated laboratory enclosure rests on the concrete table. The second stage consists of a 3000 kg granite optical table located within the enclosure and supported by another set of pneumatic isolators. The position of the two stages is monitored by proximity sensors and inclinometers with 12 degrees of freedom. The system controls 12 independent pneumatic airsprings. The signals from these sensors are fed into a personal computer based control system. The control system has maintained the position of the two stages to better than 1 micrometers in translation and 5 (mu) rad in orientation for a period of a few months. A description of the system and its characteristics is given.

  12. Development of a 3D parallel mechanism robot arm with three vertical-axial pneumatic actuators combined with a stereo vision system.

    PubMed

    Chiang, Mao-Hsiung; Lin, Hao-Ting

    2011-01-01

    This study aimed to develop a novel 3D parallel mechanism robot driven by three vertical-axial pneumatic actuators with a stereo vision system for path tracking control. The mechanical system and the control system are the primary novel parts for developing a 3D parallel mechanism robot. In the mechanical system, a 3D parallel mechanism robot contains three serial chains, a fixed base, a movable platform and a pneumatic servo system. The parallel mechanism are designed and analyzed first for realizing a 3D motion in the X-Y-Z coordinate system of the robot's end-effector. The inverse kinematics and the forward kinematics of the parallel mechanism robot are investigated by using the Denavit-Hartenberg notation (D-H notation) coordinate system. The pneumatic actuators in the three vertical motion axes are modeled. In the control system, the Fourier series-based adaptive sliding-mode controller with H(∞) tracking performance is used to design the path tracking controllers of the three vertical servo pneumatic actuators for realizing 3D path tracking control of the end-effector. Three optical linear scales are used to measure the position of the three pneumatic actuators. The 3D position of the end-effector is then calculated from the measuring position of the three pneumatic actuators by means of the kinematics. However, the calculated 3D position of the end-effector cannot consider the manufacturing and assembly tolerance of the joints and the parallel mechanism so that errors between the actual position and the calculated 3D position of the end-effector exist. In order to improve this situation, sensor collaboration is developed in this paper. A stereo vision system is used to collaborate with the three position sensors of the pneumatic actuators. The stereo vision system combining two CCD serves to measure the actual 3D position of the end-effector and calibrate the error between the actual and the calculated 3D position of the end-effector. Furthermore, to verify the feasibility of the proposed parallel mechanism robot driven by three vertical pneumatic servo actuators, a full-scale test rig of the proposed parallel mechanism pneumatic robot is set up. Thus, simulations and experiments for different complex 3D motion profiles of the robot end-effector can be successfully achieved. The desired, the actual and the calculated 3D position of the end-effector can be compared in the complex 3D motion control.

  13. Development of a 3D Parallel Mechanism Robot Arm with Three Vertical-Axial Pneumatic Actuators Combined with a Stereo Vision System

    PubMed Central

    Chiang, Mao-Hsiung; Lin, Hao-Ting

    2011-01-01

    This study aimed to develop a novel 3D parallel mechanism robot driven by three vertical-axial pneumatic actuators with a stereo vision system for path tracking control. The mechanical system and the control system are the primary novel parts for developing a 3D parallel mechanism robot. In the mechanical system, a 3D parallel mechanism robot contains three serial chains, a fixed base, a movable platform and a pneumatic servo system. The parallel mechanism are designed and analyzed first for realizing a 3D motion in the X-Y-Z coordinate system of the robot’s end-effector. The inverse kinematics and the forward kinematics of the parallel mechanism robot are investigated by using the Denavit-Hartenberg notation (D-H notation) coordinate system. The pneumatic actuators in the three vertical motion axes are modeled. In the control system, the Fourier series-based adaptive sliding-mode controller with H∞ tracking performance is used to design the path tracking controllers of the three vertical servo pneumatic actuators for realizing 3D path tracking control of the end-effector. Three optical linear scales are used to measure the position of the three pneumatic actuators. The 3D position of the end-effector is then calculated from the measuring position of the three pneumatic actuators by means of the kinematics. However, the calculated 3D position of the end-effector cannot consider the manufacturing and assembly tolerance of the joints and the parallel mechanism so that errors between the actual position and the calculated 3D position of the end-effector exist. In order to improve this situation, sensor collaboration is developed in this paper. A stereo vision system is used to collaborate with the three position sensors of the pneumatic actuators. The stereo vision system combining two CCD serves to measure the actual 3D position of the end-effector and calibrate the error between the actual and the calculated 3D position of the end-effector. Furthermore, to verify the feasibility of the proposed parallel mechanism robot driven by three vertical pneumatic servo actuators, a full-scale test rig of the proposed parallel mechanism pneumatic robot is set up. Thus, simulations and experiments for different complex 3D motion profiles of the robot end-effector can be successfully achieved. The desired, the actual and the calculated 3D position of the end-effector can be compared in the complex 3D motion control. PMID:22247676

  14. Experimental characterization of the effects of pneumatic tubing on unsteady pressure measurements

    NASA Technical Reports Server (NTRS)

    Whitmore, Stephen A.; Lindsey, William T.; Curry, Robert E.; Gilyard, Glenn B.

    1990-01-01

    Advances in aircraft control system designs have, with increasing frequency, required that air data be used as flight control feedback. This condition requires that these data be measured with accuracy and high fidelity. Most air data information is provided by pneumatic pressure measuring sensors. Typically unsteady pressure data provided by pneumatic sensing systems are distorted at high frequencies. The distortion is a result of the pressure being transmitted to the pressure sensor through a length of connective tubing. The pressure is distorted by frictional damping and wave reflection. As a result, air data provided all-flush, pneumatically sensed air data systems may not meet the frequency response requirements necessary for flight control augmentation. Both lab and flight test were performed at NASA-Ames to investigate the effects of this high frequency distortion in remotely located pressure measurement systems. Good qualitative agreement between lab and flight data are demonstrated. Results from these tests are used to describe the effects of pneumatic distortion in terms of a simple parametric model.

  15. Asymmetric Fuzzy Control of a Positive and Negative Pneumatic Pressure Servo System

    NASA Astrophysics Data System (ADS)

    Yang, Gang; Du, Jing-Min; Fu, Xiao-Yun; Li, Bao-Ren

    2017-11-01

    The pneumatic pressure control systems have been used in some fields. However, the researches on pneumatic pressure control mainly focus on constant pressure regulation. Poor dynamic characteristics and strong nonlinearity of such systems limit its application in the field of pressure tracking control. In order to meet the demand of generating dynamic pressure signal in the application of the hardware-in-the-loop simulation of aerospace engineering, a positive and negative pneumatic pressure servo system is provided to implement dynamic adjustment of sealed chamber pressure. A mathematical model is established with simulation and experiment being implemented afterwards to discuss the characteristics of the system, which shows serious asymmetry in the process of charging and discharging. Based on the analysis of the system dynamics, a fuzzy proportional integral derivative (PID) controller with asymmetric fuzzy compensator is proposed. Different from conventional adjusting mechanisms employing the error and change in error of the controlled variable as input parameters, the current chamber pressure and charging or discharging state are chosen as inputs of the compensator, which improves adaptability. To verify the effectiveness and performance of the proposed controller, the comparison experiments tracking sinusoidal and square wave commands are conducted. Experimental results show that the proposed controller can obtain better dynamic performance and relatively consistent control performance across the scope of work (2-140 kPa). The research proposes a fuzzy control method to overcome asymmetry and enhance adaptability for the positive and negative pneumatic pressure servo system.

  16. Application of Model-based Prognostics to a Pneumatic Valves Testbed

    NASA Technical Reports Server (NTRS)

    Daigle, Matthew; Kulkarni, Chetan S.; Gorospe, George

    2014-01-01

    Pneumatic-actuated valves play an important role in many applications, including cryogenic propellant loading for space operations. Model-based prognostics emphasizes the importance of a model that describes the nominal and faulty behavior of a system, and how faulty behavior progresses in time, causing the end of useful life of the system. We describe the construction of a testbed consisting of a pneumatic valve that allows the injection of faulty behavior and controllable fault progression. The valve opens discretely, and is controlled through a solenoid valve. Controllable leaks of pneumatic gas in the testbed are introduced through proportional valves, allowing the testing and validation of prognostics algorithms for pneumatic valves. A new valve prognostics approach is developed that estimates fault progression and predicts remaining life based only on valve timing measurements. Simulation experiments demonstrate and validate the approach.

  17. Speed tracking control of pneumatic motor servo systems using observation-based adaptive dynamic sliding-mode control

    NASA Astrophysics Data System (ADS)

    Chen, Syuan-Yi; Gong, Sheng-Sian

    2017-09-01

    This study aims to develop an adaptive high-precision control system for controlling the speed of a vane-type air motor (VAM) pneumatic servo system. In practice, the rotor speed of a VAM depends on the input mass air flow, which can be controlled by the effective orifice area (EOA) of an electronic throttle valve (ETV). As the control variable of a second-order pneumatic system is the integral of the EOA, an observation-based adaptive dynamic sliding-mode control (ADSMC) system is proposed to derive the differential of the control variable, namely, the EOA control signal. In the ADSMC system, a proportional-integral-derivative fuzzy neural network (PIDFNN) observer is used to achieve an ideal dynamic sliding-mode control (DSMC), and a supervisor compensator is designed to eliminate the approximation error. As a result, the ADSMC incorporates the robustness of a DSMC and the online learning ability of a PIDFNN. To ensure the convergence of the tracking error, a Lyapunov-based analytical method is employed to obtain the adaptive algorithms required to tune the control parameters of the online ADSMC system. Finally, our experimental results demonstrate the precision and robustness of the ADSMC system for highly nonlinear and time-varying VAM pneumatic servo systems.

  18. Troubleshooting of an Electromechanical System (Westinghouse PLC Controlling a Pneumatic Robot). High-Technology Training Module.

    ERIC Educational Resources Information Center

    Tucker, James D.

    This training module on the troubleshooting of an electromechanical system, The Westinghouse Programmable Logic Controller (PLC) controlling a pneumatic robot, is used for a troubleshooting unit in an electromechanical systems/robotics and automation systems course. In this unit, students locate and repair a defect in a PLC-operated machine. The…

  19. Position control of an electro-pneumatic system based on PWM technique and FLC.

    PubMed

    Najjari, Behrouz; Barakati, S Masoud; Mohammadi, Ali; Futohi, Muhammad J; Bostanian, Muhammad

    2014-03-01

    In this paper, modeling and PWM based control of an electro-pneumatic system, including the four 2-2 valves and a double acting cylinder are studied. Dynamic nonlinear behavior of the system, containing fast switching solenoid valves and a pneumatic cylinder, as well as electrical, magnetic, mechanical, and fluid subsystems are modeled. A DC-DC power converter is employed to improve solenoid valve performance and suppress system delay. Among different position control methods, a proportional integrator derivative (PID) controller and fuzzy logic controller (FLC) are evaluated. An experimental setup, using an AVR microcontroller is implemented. Simulation and experimental results verify the effectiveness of the proposed control strategies. Copyright © 2014 ISA. Published by Elsevier Ltd. All rights reserved.

  20. Flight control actuation system

    NASA Technical Reports Server (NTRS)

    Wingett, Paul T. (Inventor); Gaines, Louie T. (Inventor); Evans, Paul S. (Inventor); Kern, James I. (Inventor)

    2004-01-01

    A flight control actuation system comprises a controller, electromechanical actuator and a pneumatic actuator. During normal operation, only the electromechanical actuator is needed to operate a flight control surface. When the electromechanical actuator load level exceeds 40 amps positive, the controller activates the pneumatic actuator to offset electromechanical actuator loads to assist the manipulation of flight control surfaces. The assistance from the pneumatic load assist actuator enables the use of an electromechanical actuator that is smaller in size and mass, requires less power, needs less cooling processes, achieves high output forces and adapts to electrical current variations. The flight control actuation system is adapted for aircraft, spacecraft, missiles, and other flight vehicles, especially flight vehicles that are large in size and travel at high velocities.

  1. Flight control actuation system

    NASA Technical Reports Server (NTRS)

    Wingett, Paul T. (Inventor); Gaines, Louie T. (Inventor); Evans, Paul S. (Inventor); Kern, James I. (Inventor)

    2006-01-01

    A flight control actuation system comprises a controller, electromechanical actuator and a pneumatic actuator. During normal operation, only the electromechanical actuator is needed to operate a flight control surface. When the electromechanical actuator load level exceeds 40 amps positive, the controller activates the pneumatic actuator to offset electromechanical actuator loads to assist the manipulation of flight control surfaces. The assistance from the pneumatic load assist actuator enables the use of an electromechanical actuator that is smaller in size and mass, requires less power, needs less cooling processes, achieves high output forces and adapts to electrical current variations. The flight control actuation system is adapted for aircraft, spacecraft, missiles, and other flight vehicles, especially flight vehicles that are large in size and travel at high velocities.

  2. Genetic algorithm based active vibration control for a moving flexible smart beam driven by a pneumatic rod cylinder

    NASA Astrophysics Data System (ADS)

    Qiu, Zhi-cheng; Shi, Ming-li; Wang, Bin; Xie, Zhuo-wei

    2012-05-01

    A rod cylinder based pneumatic driving scheme is proposed to suppress the vibration of a flexible smart beam. Pulse code modulation (PCM) method is employed to control the motion of the cylinder's piston rod for simultaneous positioning and vibration suppression. Firstly, the system dynamics model is derived using Hamilton principle. Its standard state-space representation is obtained for characteristic analysis, controller design, and simulation. Secondly, a genetic algorithm (GA) is applied to optimize and tune the control gain parameters adaptively based on the specific performance index. Numerical simulations are performed on the pneumatic driving elastic beam system, using the established model and controller with tuned gains by GA optimization process. Finally, an experimental setup for the flexible beam driven by a pneumatic rod cylinder is constructed. Experiments for suppressing vibrations of the flexible beam are conducted. Theoretical analysis, numerical simulation and experimental results demonstrate that the proposed pneumatic drive scheme and the adopted control algorithms are feasible. The large amplitude vibration of the first bending mode can be suppressed effectively.

  3. Microfluidic Pneumatic Logic Circuits and Digital Pneumatic Microprocessors for Integrated Microfluidic Systems

    PubMed Central

    Rhee, Minsoung

    2010-01-01

    We have developed pneumatic logic circuits and microprocessors built with microfluidic channels and valves in polydimethylsiloxane (PDMS). The pneumatic logic circuits perform various combinational and sequential logic calculations with binary pneumatic signals (atmosphere and vacuum), producing cascadable outputs based on Boolean operations. A complex microprocessor is constructed from combinations of various logic circuits and receives pneumatically encoded serial commands at a single input line. The device then decodes the temporal command sequence by spatial parallelization, computes necessary logic calculations between parallelized command bits, stores command information for signal transportation and maintenance, and finally executes the command for the target devices. Thus, such pneumatic microprocessors will function as a universal on-chip control platform to perform complex parallel operations for large-scale integrated microfluidic devices. To demonstrate the working principles, we have built 2-bit, 3-bit, 4-bit, and 8-bit microprecessors to control various target devices for applications such as four color dye mixing, and multiplexed channel fluidic control. By significantly reducing the need for external controllers, the digital pneumatic microprocessor can be used as a universal on-chip platform to autonomously manipulate microfluids in a high throughput manner. PMID:19823730

  4. Dosing Accuracy of Insulin Aspart FlexPens After Transport Through the Pneumatic Tube System.

    PubMed

    Ward, Leah G; Heckman, Michael G; Warren, Amy I; Tran, Kimberly

    2013-01-01

    The purpose of this study was to evaluate whether transporting insulin aspart FlexPens via a pneumatic tube system affects the dosing accuracy of the pens. A total of 115 Novo Nordisk FlexPens containing insulin aspart were randomly assigned to be transported via a pneumatic tube system (n = 92) or to serve as the control (n = 23). Each pen was then randomized to 10 international unit (IU) doses (n = 25) or 30 IU doses (n = 67), providing 600 and 603 doses, respectively, for the pneumatic tube group. The control group also received random assignment to 10 IU doses (n = 6) or 30 IU doses (n = 17), providing 144 and 153 doses, respectively. Each dose was expelled using manufacturer instructions. Weights were recorded, corrected for specific gravity, and evaluated based on acceptable International Organization for Standardization (ISO) dosing limits. In the group of pens transported through the pneumatic tube system, none of the 600 doses of 10 IU (0.0%; 95% CI, 0.0 to 0.6) and none of the 603 doses of 30 IU (0.0%; 95% CI, 0.0 to 0.6) fell outside of the range of acceptable weights. Correspondingly, in the control group, none of the 144 doses at 10 IU (0.0%; 95% CI, 0.0 to 2.5) and none of the 153 doses at 30 IU (0.0%; 95% CI, 0.0 to 2.4) were outside of acceptable ISO limits. Transportation via pneumatic tube system does not appear to compromise dosing accuracy. Hospital pharmacies may rely on the pneumatic tube system for timely and accurate transport of insulin aspart FlexPens.

  5. Design of a Soft Robot with Multiple Motion Patterns Using Soft Pneumatic Actuators

    NASA Astrophysics Data System (ADS)

    Miao, Yu; Dong, Wei; Du, Zhijiang

    2017-11-01

    Soft robots are made of soft materials and have good flexibility and infinite degrees of freedom in theory. These properties enable soft robots to work in narrow space and adapt to external environment. In this paper, a 2-DOF soft pneumatic actuator is introduced, with two chambers symmetrically distributed on both sides and a jamming cylinder along the axis. Fibers are used to constrain the expansion of the soft actuator. Experiments are carried out to test the performance of the soft actuator, including bending and elongation characteristics. A soft robot is designed and fabricated by connecting four soft pneumatic actuators to a 3D-printed board. The soft robotic system is then established. The pneumatic circuit is built by pumps and solenoid valves. The control system is based on the control board Arduino Mega 2560. Relay modules are used to control valves and pressure sensors are used to measure pressure in the pneumatic circuit. Experiments are conducted to test the performance of the proposed soft robot.

  6. Microfluidic pressure amplifier circuits and electrostatic gates for pneumatic microsystems

    DOEpatents

    Tice, Joshua D.; Bassett, Thomas A.; Desai, Amit V.; Apblett, Christopher A.; Kenis, Paul J. A.

    2016-09-20

    An electrostatic actuator is provide that can include a fluidic line, a first electrode, and a second electrode such that a gate chamber portion of the fluidic line is sandwiched between the first electrode and the second electrode. The electrostatic actuator can also include a pressure-balancing channel in fluid communication with the gate chamber portion where the first electrode is sandwiched between the pressure-balancing channel and the gate chamber portion. A pneumatic valve system is provided which includes an electrostatic gate and a fluidic channel fluidly separate from a fluidic control line. A pneumatic valve portion of the fluidic control line can be positioned relative to a portion of the fluidic channel such that expansion of the pneumatic valve portion restricts fluid flow through the fluidic channel. Methods of using an electrostatic actuator and a pneumatic valve system are also provided.

  7. Control of soft machines using actuators operated by a Braille display.

    PubMed

    Mosadegh, Bobak; Mazzeo, Aaron D; Shepherd, Robert F; Morin, Stephen A; Gupta, Unmukt; Sani, Idin Zhalehdoust; Lai, David; Takayama, Shuichi; Whitesides, George M

    2014-01-07

    One strategy for actuating soft machines (e.g., tentacles, grippers, and simple walkers) uses pneumatic inflation of networks of small channels in an elastomeric material. Although the management of a few pneumatic inputs and valves to control pressurized gas is straightforward, the fabrication and operation of manifolds containing many (>50) independent valves is an unsolved problem. Complex pneumatic manifolds-often built for a single purpose-are not easily reconfigured to accommodate the specific inputs (i.e., multiplexing of many fluids, ranges of pressures, and changes in flow rates) required by pneumatic systems. This paper describes a pneumatic manifold comprising a computer-controlled Braille display and a micropneumatic device. The Braille display provides a compact array of 64 piezoelectric actuators that actively close and open elastomeric valves of a micropneumatic device to route pressurized gas within the manifold. The positioning and geometries of the valves and channels in the micropneumatic device dictate the functionality of the pneumatic manifold, and the use of multi-layer soft lithography permits the fabrication of networks in a wide range of configurations with many possible functions. Simply exchanging micropneumatic devices of different designs enables rapid reconfiguration of the pneumatic manifold. As a proof of principle, a pneumatic manifold controlled a soft machine containing 32 independent actuators to move a ball above a flat surface.

  8. Control of Soft Machines using Actuators Operated by a Braille Display

    PubMed Central

    Mosadegh, Bobak; Mazzeo, Aaron D.; Shepherd, Robert F.; Morin, Stephen A.; Gupta, Unmukt; Sani, Idin Zhalehdoust; Lai, David; Takayama, Shuichi; Whitesides, George M.

    2013-01-01

    One strategy for actuating soft machines (e.g., tentacles, grippers, and simple walkers) uses pneumatic inflation of networks of small channels in an elastomeric material. Although the management of a few pneumatic inputs and valves to control pressurized gas is straightforward, the fabrication and operation of manifolds containing many (>50) independent valves is an unsolved problem. Complex pneumatic manifolds—often built for a single purpose—are not easily reconfigured to accommodate the specific inputs (i.e., multiplexing of many fluids, ranges of pressures, and changes in flow rates) required by pneumatic systems. This paper describes a pneumatic manifold comprising a computer-controlled braille display and a micropneumatic device. The braille display provides a compact array of 64 piezoelectric actuators that actively close and open elastomeric valves of a micropneumatic device to route pressurized gas within the manifold. The positioning and geometries of the valves and channels in the micropneumatic device dictate the functionality of the pneumatic manifold, and the use of multi-layer soft lithography permits the fabrication of networks in a wide range of configurations with many possible functions. Simply exchanging micropneumatic devices of different designs enables rapid reconfiguration of the pneumatic manifold. As a proof of principle, a pneumatic manifold controlled a soft machine containing 32 independent actuators to move a ball above a flat surface. PMID:24196070

  9. Development of Pneumatic Robot Hand and Construction of Master-Slave System

    NASA Astrophysics Data System (ADS)

    Tsujiuchi, Nobutaka; Koizumi, Takayuki; Nishino, Shinya; Komatsubara, Hiroyuki; Kudawara, Tatsuwo; Hirano, Masanori

    Recently, research and development has focused on robots that work in place of people. It is necessary for robots to perform the same flexible motions as people. Additionally, such robots need to incorporate high-level safety features in order not to injure people. For creation of such robots, we need to develop a robot hand that functions like a human hand. At the same time, this type of robot hand can be used as an artificial hand. Here, we present artificial muscle-type pneumatic actuators as the driving source of a robot hand that is both safe and flexible. Some development of robot hands using pneumatic actuators has already taken place. But, until now, when a pneumatic actuator is used, a big compressor is needed. So, the driving system also needs to be big; enlargement of the driving system is a major problem. Consequently, in this research, we develop a low-pressure, low-volume pneumatic actuator for driving a robot hand that works flexibly and safely on the assumption that it will be in contact with people. We develop a five-fingered robot hand with pneumatic actuators. And, we construct a master-slave system to enable the robot hand to perform the same operations as a human hand. We make a 1-link arm that has one degree of freedom using a pneumatic actuator, and construct a control system for the 1-link arm and verify its control performance.

  10. Imparting Motion to a Test Object Such as a Motor Vehicle in a Controlled Fashion

    NASA Technical Reports Server (NTRS)

    Southward, Stephen C. (Inventor); Reubush, Chandler (Inventor); Pittman, Bryan (Inventor); Roehrig, Kurt (Inventor); Gerard, Doug (Inventor)

    2014-01-01

    An apparatus imparts motion to a test object such as a motor vehicle in a controlled fashion. A base has mounted on it a linear electromagnetic motor having a first end and a second end, the first end being connected to the base. A pneumatic cylinder and piston combination have a first end and a second end, the first end connected to the base so that the pneumatic cylinder and piston combination is generally parallel with the linear electromagnetic motor. The second ends of the linear electromagnetic motor and pneumatic cylinder and piston combination being commonly linked to a mount for the test object. A control system for the linear electromagnetic motor and pneumatic cylinder and piston combination drives the pneumatic cylinder and piston combination to support a substantial static load of the test object and the linear electromagnetic motor to impart controlled motion to the test object.

  11. Active Control of a Pneumatic Isolation System,

    DTIC Science & Technology

    A pneumatically isolated test platform has been modified to provide active control to the local gravity vector. A combination of sensors , including... tiltmeters , angular accelerometers, seismometers, and a gyrocompass measure total platform motion between 0 and 100 Hz. Electrical-to-pressure

  12. Development of an Upper Limb Power Assist System Using Pneumatic Actuators for Farming Lift-up Motion

    NASA Astrophysics Data System (ADS)

    Yagi, Eiichi; Harada, Daisuke; Kobayashi, Masaaki

    A power assist system has lately attracted considerable attention to lifting-up an object without low back pain. We have been developing power assist systems with pneumatic actuators for the elbow and shoulder to farming support of lifting-up a bag of rice weighing 30kg. This paper describes the mechanism and control method of this power assist system. The pneumatic rotary actuator supports shoulder motion, and the air cylinder supports elbow motion. In this control method, the surface electromyogram(EMG) signals are used as input information of the controller. The joint support torques of human are calculated based on the antigravity term of necessary joint torques, which are estimated on the dynamics of a human approximated link model. The experimental results show the effectiveness of the proposed mechanism and control method of the power assist system.

  13. Direct adaptive fuzzy control of a translating piezoelectric flexible manipulator driven by a pneumatic rodless cylinder

    NASA Astrophysics Data System (ADS)

    Qiu, Zhi-cheng; Wang, Bin; Zhang, Xian-min; Han, Jian-da

    2013-04-01

    This study presents a novel translating piezoelectric flexible manipulator driven by a rodless cylinder. Simultaneous positioning control and vibration suppression of the flexible manipulator is accomplished by using a hybrid driving scheme composed of the pneumatic cylinder and a piezoelectric actuator. Pulse code modulation (PCM) method is utilized for the cylinder. First, the system dynamics model is derived, and its standard multiple input multiple output (MIMO) state-space representation is provided. Second, a composite proportional derivative (PD) control algorithms and a direct adaptive fuzzy control method are designed for the MIMO system. Also, a time delay compensation algorithm, bandstop and low-pass filters are utilized, under consideration of the control hysteresis and the caused high-frequency modal vibration due to the long stroke of the cylinder, gas compression and nonlinear factors of the pneumatic system. The convergence of the closed loop system is analyzed. Finally, experimental apparatus is constructed and experiments are conducted. The effectiveness of the designed controllers and the hybrid driving scheme is verified through simulation and experimental comparison studies. The numerical simulation and experimental results demonstrate that the proposed system scheme of employing the pneumatic drive and piezoelectric actuator can suppress the vibration and achieve the desired positioning location simultaneously. Furthermore, the adopted adaptive fuzzy control algorithms can significantly enhance the control performance.

  14. Additional Development and Systems Analyses of Pneumatic Technology for High Speed Civil Transport Aircraft

    NASA Technical Reports Server (NTRS)

    Englar, Robert J.; Willie, F. Scott; Lee, Warren J.

    1999-01-01

    In the Task I portion of this NASA research grant, configuration development and experimental investigations have been conducted on a series of pneumatic high-lift and control surface devices applied to a generic High Speed Civil Transport (HSCT) model configuration to determine their potential for improved aerodynamic performance, plus stability and control of higher performance aircraft. These investigations were intended to optimize pneumatic lift and drag performance; provide adequate control and longitudinal stability; reduce separation flowfields at high angle of attack; increase takeoff/climbout lift-to-drag ratios; and reduce system complexity and weight. Experimental aerodynamic evaluations were performed on a semi-span HSCT generic model with improved fuselage fineness ratio and with interchangeable plain flaps, blown flaps, pneumatic Circulation Control Wing (CCW) high-lift configurations, plain and blown canards, a novel Circulation Control (CC) cylinder blown canard, and a clean cruise wing for reference. Conventional tail power was also investigated for longitudinal trim capability. Also evaluated was unsteady pulsed blowing of the wing high-lift system to determine if reduced pulsed mass flow rates and blowing requirements could be made to yield the same lift as that resulting from steady-state blowing. Depending on the pulsing frequency applied, reduced mass flow rates were indeed found able to provide lift augmentation at lesser blowing values than for the steady conditions. Significant improvements in the aerodynamic characteristics leading to improved performance and stability/control were identified, and the various components were compared to evaluate the pneumatic potential of each. Aerodynamic results were provided to the Georgia Tech Aerospace System Design Lab. to conduct the companion system analyses and feasibility study (Task 2) of theses concepts applied to an operational advanced HSCT aircraft. Results and conclusions from these experimental evaluations are presented herein, as are recommendations for further development and follow-on investigations. Also provided as an Appendix for reference are the basic results from the previous pneumatic HSCT investigations.

  15. A high resolution pneumatic stepping actuator for harsh reactor environments

    NASA Astrophysics Data System (ADS)

    Tippetts, Thomas B.; Evans, Paul S.; Riffle, George K.

    1993-01-01

    A reactivity control actuator for a high-power density nuclear propulsion reactor must be installed in close proximity to the reactor core. The energy input from radiation to the actuator structure could exceed hundreds of W/cc unless low-cross section, low-absorptivity materials are chosen. Also, for post-test handling and subsequent storage, materials should not be used that are activated into long half-life isotopes. Pneumatic actuators can be constructed from various reactor-compatible materials, but conventional pneumatic piston actuators generally lack the stiffness required for high resolution reactivity control unless electrical position sensors and compensated electronic control systems are used. To overcome these limitations, a pneumatic actuator is under development that positions an output shaft in response to a series of pneumatic pulses, comprising a pneumatic analog of an electrical stepping motor. The pneumatic pulses are generated remotely, beyond the strong radiation environment, and transmitted to the actuator through tubing. The mechanically simple actuator uses a nutating gear harmonic drive to convert motion of small pistons directly to high-resolution angular motion of the output shaft. The digital nature of this actuator is suitable for various reactor control algorithms but is especially compatible with the three bean salad algorithm discussed by Ball et al. (1991).

  16. A novel BCI-controlled pneumatic glove system for home-based neurorehabilitation.

    PubMed

    Coffey, Aodhán L; Leamy, Darren J; Ward, Tomás E

    2014-01-01

    Commercially available devices for Brain-Computer Interface (BCI)-controlled robotic stroke rehabilitation are prohibitively expensive for many researchers who are interested in the topic and physicians who would utilize such a device. Additionally, they are cumbersome and require a technician to operate, increasing the inaccessibility of such devices for home-based robotic stroke rehabilitation therapy. Presented here is the design, implementation and test of an inexpensive, portable and adaptable BCI-controlled hand therapy device. The system utilizes a soft, flexible, pneumatic glove which can be used to deflect the subject's wrist and fingers. Operation is provided by a custom-designed pneumatic circuit. Air flow is controlled by an embedded system, which receives serial port instruction from a PC running real-time BCI software. System tests demonstrate that glove control can be successfully driven by a real-time BCI. A system such as the one described here may be used to explore closed loop neurofeedback rehabilitation in stroke relatively inexpensively and potentially in home environments.

  17. Verification of operation of the actuator control system using the integration the B&R Automation Studio software with a virtual model of the actuator system

    NASA Astrophysics Data System (ADS)

    Herbuś, K.; Ociepka, P.

    2017-08-01

    In the work is analysed a sequential control system of a machine for separating and grouping work pieces for processing. Whereas, the area of the considered problem is related with verification of operation of an actuator system of an electro-pneumatic control system equipped with a PLC controller. Wherein to verification is subjected the way of operation of actuators in view of logic relationships assumed in the control system. The actuators of the considered control system were three drives of linear motion (pneumatic cylinders). And the logical structure of the system of operation of the control system is based on the signals flow graph. The tested logical structure of operation of the electro-pneumatic control system was implemented in the Automation Studio software of B&R company. This software is used to create programs for the PLC controllers. Next, in the FluidSIM software was created the model of the actuator system of the control system of a machine. To verify the created program for the PLC controller, simulating the operation of the created model, it was utilized the approach of integration these two programs using the tool for data exchange in the form of the OPC server.

  18. RaPToRS Sample Delivery System

    NASA Astrophysics Data System (ADS)

    Henchen, Robert; Shibata, Kye; Krieger, Michael; Pogozelski, Edward; Padalino, Stephen; Glebov, Vladimir; Sangster, Craig

    2010-11-01

    At various labs (NIF, LLE, NRL), activated material samples are used to measure reaction properties. The Rapid Pneumatic Transport of Radioactive Samples (RaPToRS) system quickly and safely moves these radioactive samples through a closed PVC tube via airflow. The carrier travels from the reaction chamber to the control and analysis station, pneumatically braking at the outlet. A reversible multiplexer routes samples from various locations near the shot chamber to the analysis station. Also, the multiplexer allows users to remotely load unactivated samples without manually approaching the reaction chamber. All elements of the system (pneumatic drivers, flow control valves, optical position sensors, multiplexers, Geiger counters, and release gates at the analysis station) can be controlled manually or automatically using a custom LabVIEW interface. A prototype is currently operating at NRL in Washington DC. Prospective facilities for Raptors systems include LLE and NIF.

  19. Electropneumatic transducer automatically limits motor current

    NASA Technical Reports Server (NTRS)

    Lovitt, T. F.

    1966-01-01

    Pneumatic controller regulates the load on a centrifugal freon compressor in a water cooling system, thus limiting the current input to an electric motor driving it. An electromechanical transducer monitoring the motor input current sends out air signals which indicate changes in the current to the pneumatic controller.

  20. 117. PNEUMATIC SUPPLY PANEL IN CENTER OF VEHICLE MECHANICAL SYSTEMS ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    117. PNEUMATIC SUPPLY PANEL IN CENTER OF VEHICLE MECHANICAL SYSTEMS ROOM (111), LSB (BLDG. 770), FACING NORTH. CONTROLS FOR FLOW AND PRESSURE REGULATION OF HELIUM ON LEFT SIDE OF PANEL; CONTROLS FOR NITROGEN ON RIGHT SIDE OF PANEL (AT RIGHT EDGE OF PHOTO). - Vandenberg Air Force Base, Space Launch Complex 3, Launch Pad 3 West, Napa & Alden Roads, Lompoc, Santa Barbara County, CA

  1. 116. PNEUMATIC SUPPLY PANEL IN CENTER OF VEHICLE MECHANICAL SYSTEMS ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    116. PNEUMATIC SUPPLY PANEL IN CENTER OF VEHICLE MECHANICAL SYSTEMS ROOM (111) OF LSB (BLDG. 770), FACING NORTH. CONTROLS FOR FLOW AND PRESSURE REGULATION OF NITROGEN ON RIGHT SIDE OF PANEL; CONTROLS FOR HELIUM ON LEFT SIDE OF PANEL (AT LEFT EDGE OF PHOTO). - Vandenberg Air Force Base, Space Launch Complex 3, Launch Pad 3 West, Napa & Alden Roads, Lompoc, Santa Barbara County, CA

  2. A High-Speed Continuous Recording High Flow Gas Sampler for Measuring Methane Emissions from Pneumatic Devices at Oil and Natural Gas Production Facilities

    NASA Astrophysics Data System (ADS)

    Ferrara, T.; Howard, T. M.

    2016-12-01

    Studies attempting to reconcile facility level emission estimates of sources at oil and gas facilities with basin wide methane flux measurements have had limited success. Pneumatic devices are commonly used at oil and gas production facilities for process control or liquid pumping. These devices are powered by pressurized natural gas from the well, so they are known methane sources at these sites. Pneumatic devices are estimated to contribute 14% to 25% of the total greenhouse gas emissions (GHG) from production facilities. Measurements of pneumatic devices have shown that malfunctioning or poorly maintained control systems may be emitting significantly more methane than currently estimated. Emission inventories for these facilities use emission factors from EPA that are based on pneumatic device measurements made in the early 1990's. Recent studies of methane emissions from production facilities have attempted to measure emissions from pneumatic devices by several different methods. These methods have had limitations including alteration of the system being measured, the inability to distinguish between leaks and venting during normal operation, or insufficient response time to account of the time based emission events. We have developed a high speed recording high flow sampler that is capable of measuring the transient emissions from pneumatic devices. This sampler is based on the well-established high flow measurement technique used in oil and gas for quantifying component leak rates. In this paper we present the results of extensive laboratory controlled release testing. Additionally, test data from several field studies where this sampler has been used to measure pneumatic device emissions will be presented.

  3. Feasibility study of a biocompatible pneumatic dispensing system using mouse 3T3-J2 fibroblasts

    NASA Astrophysics Data System (ADS)

    Lee, Sangmin; Kim, Hojin; Kim, Joonwon

    2017-12-01

    This paper presents results for dispensing living cells using a pneumatic dispensing system to verify the feasibility of using this system to fabricate biomaterials. Living cells (i.e., mouse 3T3-J2 fibroblast) were dispensed with different dispensing pressures in order to evaluate the effect of dispensing process on cell viability and proliferation. Based on the results of a live-dead assay, more than 80% of cell viability has been confirmed which was reasonably similar to that in the control group. Furthermore, measurement of cell metabolic activity after dispensing confirmed that the dispensed cell proliferated at a rate comparable to that of the control group. These results demonstrate that the pneumatic dispensing system is a promising tool for fabrication of biomaterials.

  4. First Approach of Pneumatic Anthropomorphic Hand

    DTIC Science & Technology

    2001-10-25

    1 o f 3 FIRST APPROACH OF PNEUMATIC ANTHROPOMORPHIC HAND Jiménez, Omar; Leija, Lorenzo; Muñoz, Roberto Centro de Investigación y de Estudios...weight and minimum consumption, minimum control and natural appearance. Keywords- Anthropomorphic, hand, Pneumatic system, Prosthesis 1 . INTRODUCTION...The projects have been guided through an specific line of development. The project MARCUS[ 1 ] includes easiness as the most important aspect what

  5. Assessment of Uinta Basin Oil and Natural Gas Well Pad Pneumatic Controller Emissions

    EPA Science Inventory

    In the fall of 2016, a field study was conducted in the Uinta Basin Utah to improve information on oil and natural gas well pad pneumatic controllers (PCs) and emission measurement methods. A total of 80 PC systems at five oil sites (supporting six wells) and three gas sites (sup...

  6. Modular Systems Of Fixation And Position Jigs In The Production Process For Products And Systems

    NASA Astrophysics Data System (ADS)

    Babík, Ondrej; Šajgalík, Michal; Zaušková, Lucia; Czán, Andrej

    2015-12-01

    The project deals with design and implementation of adjustment onto mounting tables in the automotive industry. Manual control system of the jigs is replaced by a pneumatic system. Advantages of the pneumatic system are eliminating service side-time, improving work flow and increasing safety and ergonomics at work. Thanks to higher effectivity of the work process, manpower can be used in other work positions.

  7. Pressurization, Pneumatic, and Vent Subsystems of the X-34 Main Propulsion System

    NASA Technical Reports Server (NTRS)

    Hedayat, A.; Steadman, T. E.; Brown, T. M.; Knight, K. C.; White, C. E., Jr.; Champion, R. H., Jr.

    1998-01-01

    In pressurization systems, regulators and orifices are use to control the flow of the pressurant. For the X-34 Main Propulsion System, three pressurization subsystem design configuration options were considered. In the first option, regulators were used while in the other options, orifices were considered. In each design option, the vent/relief system must be capable of relieving the pressurant flow without allowing the tank pressure to rise above proof, therefore, impacts on the propellant tank vent system were investigated and a trade study of the pressurization system was conducted. The analysis indicated that design option using regulators poses least risk. Then, a detailed transient thermal/fluid analysis of the recommended pressurization system was performed. Helium usage, thermodynamic conditions, and overpressurization of each propellant tank were evaluated. The pneumatic and purge subsystem is used for pneumatic valve actuation, Inter-Propellant Seal purges, Engine Spin Start, and engine purges at the required interface pressures, A transient analysis of the pneumatic and purge subsystem provided helium usage and flow rates to Inter-Propellant Seal and engine interfaces. Fill analysis of the helium bottles of pressurization and pneumatic subsystems during ground operation was performed. The required fill time and the stored

  8. Powered glove with electro-pneumatic actuation unit for the disabled

    NASA Astrophysics Data System (ADS)

    Kawakami, Kosuke; Kumano, Shinichi; Moromugi, Shunji; Ishimatsu, Takakazu

    2007-12-01

    Authors have been developing a powered glove for people suffering from paralysis on their fingers to support their daily activity. Small air cylinders are used as actuators for this glove. Pneumatically-driven system has high advantages in case soft actuation is preferable. However, there are some problems to be solved in the pneumatically-driven system if the system is supposed to be used in our daily life. Huge air compressor is needed and solenoid valves emit loud sound for example. These problems are hurdles to commercialize the powered glove. To solve these problems authors have developed a new actuation unit by integrating an electric cylinder and an air cylinder. This actuation unit has advantages of both the electric actuation and the pneumatic actuation. Its advanced grip control ability has demonstrated through several experiments. The experimental results are reported in this paper.

  9. Sliding pressure control valve for pneumatic hammer drill

    DOEpatents

    Polsky, Yarom [Albuquerque, NM

    2011-08-30

    A pneumatic device control apparatus and method comprising a ported valve slidably fitted over a feed tube of the pneumatic device, and using a compliant biasing device to constrain motion of the valve to provide asymmetric timing for extended pressurization of a power chamber and reduced pressurization of a return chamber of the pneumatic device. The pneumatic device can be a pneumatic hammer drill.

  10. Precharged Pneumatic Soft Actuators and Their Applications to Untethered Soft Robots.

    PubMed

    Li, Yunquan; Chen, Yonghua; Ren, Tao; Li, Yingtian; Choi, Shiu Hong

    2018-06-20

    The past decade has witnessed tremendous progress in soft robotics. Unlike most pneumatic-based methods, we present a new approach to soft robot design based on precharged pneumatics (PCP). We propose a PCP soft bending actuator, which is actuated by precharged air pressure and retracted by inextensible tendons. By pulling or releasing the tendons, the air pressure in the soft actuator is modulated, and hence, its bending angle. The tendons serve in a way similar to pressure-regulating valves that are used in typical pneumatic systems. The linear motion of tendons is transduced into complex motion via the prepressurized bent soft actuator. Furthermore, since a PCP actuator does not need any gas supply, complicated pneumatic control systems used in traditional soft robotics are eliminated. This facilitates the development of compact untethered autonomous soft robots for various applications. Both theoretical modeling and experimental validation have been conducted on a sample PCP soft actuator design. A fully untethered autonomous quadrupedal soft robot and a soft gripper have been developed to demonstrate the superiority of the proposed approach over traditional pneumatic-driven soft robots.

  11. Pneumatic Conveying of Seed Cotton: Minimum Velocity and Pressure Drop

    USDA-ARS?s Scientific Manuscript database

    Electricity is major cost for cotton gins, representing approximately 20% of the industry’s variable costs. Fans used for pneumatic conveying consume the majority of electricity at cotton gins. Development of control systems to reduce the air velocity used for conveying seed cotton could significant...

  12. Pneumatic Conveying of Seed Cotton: Minimum Velocity and Pressure Drop

    USDA-ARS?s Scientific Manuscript database

    Electricity is a major cost for cotton gins, representing approximately 20% of variable costs. Fans used for pneumatic conveying consume the majority of electricity at cotton gins. Development of control systems to reduce the air velocity used for conveying seed cotton could significantly decrease e...

  13. Dynamic Analysis of Sounding Rocket Pneumatic System Revision

    NASA Technical Reports Server (NTRS)

    Armen, Jerald

    2010-01-01

    The recent fusion of decades of advancements in mathematical models, numerical algorithms and curve fitting techniques marked the beginning of a new era in the science of simulation. It is becoming indispensable to the study of rockets and aerospace analysis. In pneumatic system, which is the main focus of this paper, particular emphasis will be placed on the efforts of compressible flow in Attitude Control System of sounding rocket.

  14. Aerodynamic control of NASP-type vehicles through vortex manipulation, volume 4

    NASA Technical Reports Server (NTRS)

    Smith, Brooke C.; Suarez, Carlos J.; Porada, William M.; Malcolm, Gerald N.

    1993-01-01

    Forebody Vortex Control (FVC) is an emerging technology that has received widespread and concentrated attention by many researchers for application on fighter aircraft to enhance aerodynamic controllability at high angles of attack. This research explores potential application of FVC to a NASP-type configuration. The configuration investigated is characterized by a slender, circular cross-section forebody and a 78 deg swept delta wing. A man-in-the-loop, six-degress-of-freedom, high-fidelity simulation was developed that demonstrates the implementation and advantages of pneumatic forebody vortex control. Static wind tunnel tests were used as the basis for the aerodynamic characteristics modeled in the simulation. Dynamic free-to-roll wind tunnel tests were analyzed and the wing rock motion investigated. A non-linear model of the dynamic effects of the bare airframe and the forebody vortex control system were developed that closely represented the observed behavior. Multiple state-of-the-art digital flight control systems were developed that included different utilizations of pneumatic vortex control. These were evaluated through manned simulation. Design parameters for a pneumatic forebody vortex control system were based on data collected regarding the use of blowing and the mass flow required during realistic flight maneuvers.

  15. Propulsion System with Pneumatic Artificial Muscles for Powering Ankle-Foot Orthosis

    NASA Astrophysics Data System (ADS)

    Veneva, Ivanka; Vanderborght, Bram; Lefeber, Dirk; Cherelle, Pierre

    2013-12-01

    The aim of this paper is to present the design of device for control of new propulsion system with pneumatic artificial muscles. The propulsion system can be used for ankle joint articulation, for assisting and rehabilitation in cases of injured ankle-foot complex, stroke patients or elderly with functional weakness. Proposed device for control is composed by microcontroller, generator for muscles contractions and sensor system. The microcontroller receives the control signals from sensors and modulates ankle joint flex- ion and extension during human motion. The local joint control with a PID (Proportional-Integral Derivative) position feedback directly calculates desired pressure levels and dictates the necessary contractions. The main goal is to achieve an adaptation of the system and provide the necessary joint torque using position control with feedback.

  16. 75 FR 51243 - Trade Mission to the Port of Veracruz

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-08-19

    ... collection and management, hazardous materials handling, maritime inspection, operations control, designing... control systems; --Pneumatic delivery systems; --Software for inventory tracking; --Used mobile railcar...

  17. Fully chip-embedded automation of a multi-step lab-on-a-chip process using a modularized timer circuit.

    PubMed

    Kang, Junsu; Lee, Donghyeon; Heo, Young Jin; Chung, Wan Kyun

    2017-11-07

    For highly-integrated microfluidic systems, an actuation system is necessary to control the flow; however, the bulk of actuation devices including pumps or valves has impeded the broad application of integrated microfluidic systems. Here, we suggest a microfluidic process control method based on built-in microfluidic circuits. The circuit is composed of a fluidic timer circuit and a pneumatic logic circuit. The fluidic timer circuit is a serial connection of modularized timer units, which sequentially pass high pressure to the pneumatic logic circuit. The pneumatic logic circuit is a NOR gate array designed to control the liquid-controlling process. By using the timer circuit as a built-in signal generator, multi-step processes could be done totally inside the microchip without any external controller. The timer circuit uses only two valves per unit, and the number of process steps can be extended without limitation by adding timer units. As a demonstration, an automation chip has been designed for a six-step droplet treatment, which entails 1) loading, 2) separation, 3) reagent injection, 4) incubation, 5) clearing and 6) unloading. Each process was successfully performed for a pre-defined step-time without any external control device.

  18. Control law system for X-Wing aircraft

    NASA Technical Reports Server (NTRS)

    Lawrence, Thomas H. (Inventor); Gold, Phillip J. (Inventor)

    1990-01-01

    Control law system for the collective axis, as well as pitch and roll axes, of an X-Wing aircraft and for the pneumatic valving controlling circulation control blowing for the rotor. As to the collective axis, the system gives the pilot single-lever direct lift control and insures that maximum cyclic blowing control power is available in transition. Angle-of-attach de-coupling is provided in rotary wing flight, and mechanical collective is used to augment pneumatic roll control when appropriate. Automatic gain variations with airspeed and rotor speed are provided, so a unitary set of control laws works in all three X-Wing flight modes. As to pitch and roll axes, the system produces essentially the same aircraft response regardless of flight mode or condition. Undesirable cross-couplings are compensated for in a manner unnoticeable to the pilot without requiring pilot action, as flight mode or condition is changed. A hub moment feedback scheme is implemented, utilizing a P+I controller, significantly improving bandwidth. Limits protect aircraft structure from inadvertent damage. As to pneumatic valving, the system automatically provides the pressure required at each valve azimuth location, as dictated by collective, cyclic and higher harmonic blowing commands. Variations in the required control phase angle are automatically introduced, and variations in plenum pressure are compensated for. The required switching for leading, trailing and dual edge blowing is automated, using a simple table look-up procedure. Non-linearities due to valve characteristics of circulation control lift are linearized by map look-ups.

  19. Teleoperation System with Hybrid Pneumatic-Piezoelectric Actuation for MRI-Guided Needle Insertion with Haptic Feedback

    PubMed Central

    Shang, Weijian; Su, Hao; Li, Gang; Fischer, Gregory S.

    2014-01-01

    This paper presents a surgical master-slave tele-operation system for percutaneous interventional procedures under continuous magnetic resonance imaging (MRI) guidance. This system consists of a piezoelectrically actuated slave robot for needle placement with integrated fiber optic force sensor utilizing Fabry-Perot interferometry (FPI) sensing principle. The sensor flexure is optimized and embedded to the slave robot for measuring needle insertion force. A novel, compact opto-mechanical FPI sensor interface is integrated into an MRI robot control system. By leveraging the complementary features of pneumatic and piezoelectric actuation, a pneumatically actuated haptic master robot is also developed to render force associated with needle placement interventions to the clinician. An aluminum load cell is implemented and calibrated to close the impedance control loop of the master robot. A force-position control algorithm is developed to control the hybrid actuated system. Teleoperated needle insertion is demonstrated under live MR imaging, where the slave robot resides in the scanner bore and the user manipulates the master beside the patient outside the bore. Force and position tracking results of the master-slave robot are demonstrated to validate the tracking performance of the integrated system. It has a position tracking error of 0.318mm and sine wave force tracking error of 2.227N. PMID:25126446

  20. Teleoperation System with Hybrid Pneumatic-Piezoelectric Actuation for MRI-Guided Needle Insertion with Haptic Feedback.

    PubMed

    Shang, Weijian; Su, Hao; Li, Gang; Fischer, Gregory S

    2013-01-01

    This paper presents a surgical master-slave tele-operation system for percutaneous interventional procedures under continuous magnetic resonance imaging (MRI) guidance. This system consists of a piezoelectrically actuated slave robot for needle placement with integrated fiber optic force sensor utilizing Fabry-Perot interferometry (FPI) sensing principle. The sensor flexure is optimized and embedded to the slave robot for measuring needle insertion force. A novel, compact opto-mechanical FPI sensor interface is integrated into an MRI robot control system. By leveraging the complementary features of pneumatic and piezoelectric actuation, a pneumatically actuated haptic master robot is also developed to render force associated with needle placement interventions to the clinician. An aluminum load cell is implemented and calibrated to close the impedance control loop of the master robot. A force-position control algorithm is developed to control the hybrid actuated system. Teleoperated needle insertion is demonstrated under live MR imaging, where the slave robot resides in the scanner bore and the user manipulates the master beside the patient outside the bore. Force and position tracking results of the master-slave robot are demonstrated to validate the tracking performance of the integrated system. It has a position tracking error of 0.318mm and sine wave force tracking error of 2.227N.

  1. Pneumatic load compensating or controlling system

    NASA Technical Reports Server (NTRS)

    Rogers, J. R. (Inventor)

    1975-01-01

    A pneumatic load compensating or controlling system for restraining a load with a predetermined force or applying a predetermined force to the load is described; it includes a source of pressurized air, a one-way pneumatic actuator operatively connected to a load, and a fluid conduit fluidically connecting the actuator with the source of pressurized air. The actuator is of the piston and cylinder type, and the end of the fluid conduit is connected to the upper or lower portion of the cylinder whereby the actuator alternatively and selectively restrains the load with a predetermined force or apply a predetermined force to the load. Pressure regulators are included within the system for variably selectively adjusting the pressurized fluid to predetermined values as desired or required; a pressure amplifier is included within the system for multiplying the pressurized values so as to achieve greater load forces. An accumulator is incorporated within the system as a failsafe operating mechanism, and visual and aural alarm devices, operatively associated with pressure detecting apparatus, readily indicate the proper or improper functioning of the system.

  2. Closed-loop helium circulation system for actuation of a continuously operating heart catheter pump.

    PubMed

    Karabegovic, Alen; Hinteregger, Markus; Janeczek, Christoph; Mohl, Werner; Gföhler, Margit

    2017-06-09

    Currently available, pneumatic-based medical devices are operated using closed-loop pulsatile or open continuous systems. Medical devices utilizing gases with a low atomic number in a continuous closed loop stream have not been documented to date. This work presents the construction of a portable helium circulation addressing the need for actuating a novel, pneumatically operated catheter pump. The design of its control system puts emphasis on the performance, safety and low running cost of the catheter pump. Static and dynamic characteristics of individual elements in the circulation are analyzed to ensure a proper operation of the system. The pneumatic circulation maximizes the working range of the drive unit inside the catheter pump while reducing the total size and noise production.Separate flow and pressure controllers position the turbine's working point into the stable region of the pressure creation element. A subsystem for rapid gas evacuation significantly decreases the duration of helium removal after a leak, reaching subatmospheric pressure in the intracorporeal catheter within several milliseconds. The system presented in the study offers an easy control of helium mass flow while ensuring stable behavior of its internal components.

  3. Analysis of fine coal pneumatic systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mathur, M.P.; Rohatgi, N.D.; Klinzing, G.E.

    1987-01-01

    Many fossil fuel energy processes depend on the movement of solids by pneumatic transport. Despite the considerable amount of work reported in the literature on pneumatic transport, the design of new industrial systems for new products continues to rely to a great extent on empiricism. A pilot-scale test facility has been constructed at Pittsburgh Energy Technology Center (PETC) and is equipped with modern sophisticated measuring techniques (such as Pressure Transducers, Auburn Monitors, Micro Motion Mass flowmeters) and an automatic computer-controlled data acquisition system to study the effects of particle pneumatic transport. Pittsburgh Seam and Montana rosebud coals of varying sizemore » consist and moisture content were tested in the atmospheric and pressurized coal flow test loops (AP/CFTL and HP/CFTL) at PETC. The system parameters included conveying gas velocity, injector tank pressure, screw conveyor speed, pipe radius, and pipe bends. In the following report, results from the coal flow tests were presented and analyzed. Existing theories and correlations on two-phase flows were reviewed. Experimental data were compared with values calculated from empirically or theoretically derived equations available in the literature, and new correlations were proposed, when applicable, to give a better interpretation of the data and a better understanding of the various flow regimes involved in pneumatic transport. 55 refs., 56 figs., 6 tabs.« less

  4. The Application of LOGO! in Control System of a Transmission and Sorting Mechanism

    NASA Astrophysics Data System (ADS)

    Liu, Jian; Lv, Yuan-Jun

    Logic programming of general logic control module LOGO! has been recommended the application in transmission and sorting mechanism. First, the structure and operating principle of the mechanism had been introduced. Then the pneumatic loop of the mechanism had been plotted in the software of FluidSIM-P. At last, pneumatic loop and motors had been control by LOGO!, which makes the control process simple and clear instead of the complicated control of ordinary relay. LOGO! can achieve the complicated interlock control composed of inter relays and time relays. In the control process, the logic control function of LOGO! is fully used to logic programming so that the system realizes the control of air cylinder and motor. It is reliable and adjustable mechanism after application.

  5. 14 CFR 23.1416 - Pneumatic de-icer boot system.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... Safety Equipment § 23.1416 Pneumatic de-icer boot system. If certification with ice protection provisions is desired and a pneumatic de-icer boot system is installed— (a) The system must meet the... 14 Aeronautics and Space 1 2012-01-01 2012-01-01 false Pneumatic de-icer boot system. 23.1416...

  6. 14 CFR 23.1416 - Pneumatic de-icer boot system.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... Safety Equipment § 23.1416 Pneumatic de-icer boot system. If certification with ice protection provisions is desired and a pneumatic de-icer boot system is installed— (a) The system must meet the... 14 Aeronautics and Space 1 2014-01-01 2014-01-01 false Pneumatic de-icer boot system. 23.1416...

  7. 14 CFR 23.1416 - Pneumatic de-icer boot system.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... Safety Equipment § 23.1416 Pneumatic de-icer boot system. If certification with ice protection provisions is desired and a pneumatic de-icer boot system is installed— (a) The system must meet the... 14 Aeronautics and Space 1 2013-01-01 2013-01-01 false Pneumatic de-icer boot system. 23.1416...

  8. 14 CFR 23.1416 - Pneumatic de-icer boot system.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Pneumatic de-icer boot system. 23.1416... Safety Equipment § 23.1416 Pneumatic de-icer boot system. If certification with ice protection provisions is desired and a pneumatic de-icer boot system is installed— (a) The system must meet the...

  9. 14 CFR 23.1416 - Pneumatic de-icer boot system.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Pneumatic de-icer boot system. 23.1416... Safety Equipment § 23.1416 Pneumatic de-icer boot system. If certification with ice protection provisions is desired and a pneumatic de-icer boot system is installed— (a) The system must meet the...

  10. Wheel slide protection control using a command map and Smith predictor for the pneumatic brake system of a railway vehicle

    NASA Astrophysics Data System (ADS)

    Lee, Nam-Jin; Kang, Chul-Goo

    2016-10-01

    In railway vehicles, excessive sliding or wheel locking can occur while braking because of a temporarily degraded adhesion between the wheel and the rail caused by the contaminated or wet surface of the rail. It can damage the wheel tread and affect the performance of the brake system and the safety of the railway vehicle. To safeguard the wheelset from these phenomena, almost all railway vehicles are equipped with wheel slide protection (WSP) systems. In this study, a new WSP algorithm is proposed. The features of the proposed algorithm are the use of the target sliding speed, the determination of a command for WSP valves using command maps, and compensation for the time delay in pneumatic brake systems using the Smith predictor. The proposed WSP algorithm was verified using experiments with a hardware-in-the-loop simulation system including the hardware of the pneumatic brake system.

  11. A comparison of hydraulic, pneumatic, and electro-mechanical actuators for general aviation flight controls

    NASA Technical Reports Server (NTRS)

    Roskam, J.; Rice, M.; Eysink, H.

    1979-01-01

    Mathematical models for electromechanical (EM), pneumatic and hydraulic actuations are discussed. It is shown that EM and hydraulic actuators provide better and faster time responses than pneumatic actuators but EM actuators utilizing the recently developed samarium-cobalt technology have significant advantages in terms of size, weight and power requirements. In terms of ease and flexibility of installation EM actuators apparently have several advantages over hydraulic actuators, and cost is a primary reason for the popularity of EM actuation for secondary control function since no additional systems need to be added to the aircraft. While new rare earth magnets are currently in developmental stage, costs are relatively high; but continued research should bring prices down.

  12. Pneumatic Variable Series Elastic Actuator.

    PubMed

    Zheng, Hao; Wu, Molei; Shen, Xiangrong

    2016-08-01

    Inspired by human motor control theory, stiffness control is highly effective in manipulation and human-interactive tasks. The implementation of stiffness control in robotic systems, however, has largely been limited to closed-loop control, and suffers from multiple issues such as limited frequency range, potential instability, and lack of contribution to energy efficiency. Variable-stiffness actuator represents a better solution, but the current designs are complex, heavy, and bulky. The approach in this paper seeks to address these issues by using pneumatic actuator as a variable series elastic actuator (VSEA), leveraging the compressibility of the working fluid. In this work, a pneumatic actuator is modeled as an elastic element with controllable stiffness and equilibrium point, both of which are functions of air masses in the two chambers. As such, for the implementation of stiffness control in a robotic system, the desired stiffness/equilibrium point can be converted to the desired chamber air masses, and a predictive pressure control approach is developed to control the timing of valve switching to obtain the desired air mass while minimizing control action. Experimental results showed that the new approach in this paper requires less expensive hardware (on-off valve instead of proportional valve), causes less control action in implementation, and provides good control performance by leveraging the inherent dynamics of the actuator.

  13. Pneumatic Variable Series Elastic Actuator

    PubMed Central

    Zheng, Hao; Wu, Molei; Shen, Xiangrong

    2016-01-01

    Inspired by human motor control theory, stiffness control is highly effective in manipulation and human-interactive tasks. The implementation of stiffness control in robotic systems, however, has largely been limited to closed-loop control, and suffers from multiple issues such as limited frequency range, potential instability, and lack of contribution to energy efficiency. Variable-stiffness actuator represents a better solution, but the current designs are complex, heavy, and bulky. The approach in this paper seeks to address these issues by using pneumatic actuator as a variable series elastic actuator (VSEA), leveraging the compressibility of the working fluid. In this work, a pneumatic actuator is modeled as an elastic element with controllable stiffness and equilibrium point, both of which are functions of air masses in the two chambers. As such, for the implementation of stiffness control in a robotic system, the desired stiffness/equilibrium point can be converted to the desired chamber air masses, and a predictive pressure control approach is developed to control the timing of valve switching to obtain the desired air mass while minimizing control action. Experimental results showed that the new approach in this paper requires less expensive hardware (on–off valve instead of proportional valve), causes less control action in implementation, and provides good control performance by leveraging the inherent dynamics of the actuator. PMID:27354755

  14. A new pneumatic suspension system with independent stiffness and ride height tuning capabilities

    NASA Astrophysics Data System (ADS)

    Yin, Zhihong; Khajepour, Amir; Cao, Dongpu; Ebrahimi, Babak; Guo, Konghui

    2012-12-01

    This paper introduces a new pneumatic spring for vehicle suspension systems, allowing independent tuning of stiffness and ride height according to different vehicle operating conditions and driver preferences. The proposed pneumatic spring comprises a double-acting pneumatic cylinder, two accumulators and a tuning subsystem. This paper presents a detailed description of the pneumatic spring and its working principle. The mathematical model is established based on principles of thermo and fluid dynamics. An experimental setup has been designed and fabricated for testing and evaluating the proposed pneumatic spring. The analytical and experimental results confirm the capability of the new pneumatic spring system for independent tuning of stiffness and ride height. The mathematical model is verified and the capabilities of the pneumatic spring are further proved. It is concluded that this new pneumatic spring provides a more flexible suspension design alternative for meeting various conflicting suspension requirements for ride comfort and performance.

  15. Linear Test Bed. Volume 2: Test Bed No. 2. [linear aerospike test bed for thrust vector control

    NASA Technical Reports Server (NTRS)

    1974-01-01

    Test bed No. 2 consists of 10 combustors welded in banks of 5 to 2 symmetrical tubular nozzle assemblies, an upper stationary thrust frame, a lower thrust frame which can be hinged, a power package, a triaxial combustion wave ignition system, a pneumatic control system, pneumatically actuated propellant valves, a purge and drain system, and an electrical control system. The power package consists of the Mark 29-F fuel turbopump, the Mark 29-0 oxidizer turbopump, a gas generator assembly, and propellant ducting. The system, designated as a linear aerospike system, was designed to demonstrate the feasibility of the concept and to explore technology related to thrust vector control, thrust vector optimization, improved sequencing and control, and advanced ignition systems. The propellants are liquid oxygen/liquid hydrogen. The system was designed to operate at 1200-psia chamber pressure at an engine mixture ratio of 5.5. With 10 combustors, the sea level thrust is 95,000 pounds.

  16. 46 CFR 108.409 - Location and spacing of tubing in pneumatic fire detection system.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... detection system. 108.409 Section 108.409 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED... and spacing of tubing in pneumatic fire detection system. (a) All tubing in a pneumatic fire detection... exposed in the space. (c) A pneumatic fire detection system must be set to activate after approximately a...

  17. Design and performance of heart assist or artificial heart control systems

    NASA Technical Reports Server (NTRS)

    Webb, J. A., Jr.; Gebben, V. D.

    1978-01-01

    The factors leading to the design of a controlled driving system for either a heart assist pump or artificial heart are discussed. The system provides square pressure waveform to drive a pneumatic-type blood pump. For assist usage the system uses an R-wave detector circuit that can detect the R-wave of the electrocardiogram in the presence of electrical disturbances. This circuit provides a signal useful for synchronizing an assist pump with the natural heart. It synchronizes a square wave circuit, the output of which is converted into square waveforms of pneumatic pressure suitable for driving both assist device and artificial heart. The pressure levels of the driving waveforms are controlled by means of feedback channels to maintain physiological regulation of the artificial heart's output flow. A more compact system that could achieve similar regulatory characteristics is also discussed.

  18. Chapter 22: Compressed Air Evaluation Protocol. The Uniform Methods Project: Methods for Determining Energy Efficiency Savings for Specific Measures

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kurnik, Charles W; Benton, Nathanael; Burns, Patrick

    Compressed-air systems are used widely throughout industry for many operations, including pneumatic tools, packaging and automation equipment, conveyors, and other industrial process operations. Compressed-air systems are defined as a group of subsystems composed of air compressors, air treatment equipment, controls, piping, pneumatic tools, pneumatically powered machinery, and process applications using compressed air. A compressed-air system has three primary functional subsystems: supply, distribution, and demand. Air compressors are the primary energy consumers in a compressed-air system and are the primary focus of this protocol. The two compressed-air energy efficiency measures specifically addressed in this protocol are: High-efficiency/variable speed drive (VSD) compressormore » replacing modulating, load/unload, or constant-speed compressor; and Compressed-air leak survey and repairs. This protocol provides direction on how to reliably verify savings from these two measures using a consistent approach for each.« less

  19. A description of model 3B of the multipurpose ventricular actuating system. [providing controlled driving pressures

    NASA Technical Reports Server (NTRS)

    Webb, J. A., Jr.

    1974-01-01

    The multipurpose ventricular actuating system is a pneumatic signal generating device that provides controlled driving pressures for actuating pulsatile blood pumps. Overall system capabilities, the timing circuitry, and calibration instruction are included.

  20. JUH-1H Redesigned Pneumatic Boot Deicing System Flight Test Evaluation

    DTIC Science & Technology

    1987-08-01

    Company (BFG) Initiated a program to evaluate the feasibility of pneumatic deicing systems for helicopter rotor blades. The concept was revived by...Goodrich Company (BFG) polyurethane erosion material. All tubes 53 Photo 6. Control Switch V. in each delcer are simultaneously Inflated...laaaaaaaaaaaaaBBaaaa «••aaaaaaaffaaaaaaaaaaaaaaaaeaaaaaaaHaaaaaaaaaaa««««*«* a afiaa.a.aaaaaaaaaan a sa aa aaa ■ 8a»a saa B^iiBaBa ax ■ aa aaa aa aal .a

  1. A reduced-order model-based study on the effect of intermittent pneumatic compression of limbs on the cardiovascular system.

    PubMed

    Maffiodo, Daniela; De Nisco, Giuseppe; Gallo, Diego; Audenino, Alberto; Morbiducci, Umberto; Ferraresi, Carlo

    2016-04-01

    This work investigates the effect that the application of intermittent pneumatic compression to lower limbs has on the cardiovascular system. Intermittent pneumatic compression can be applied to subjects with reduced or null mobility and can be useful for therapeutic purposes in sports recovery, deep vein thrombosis prevention and lymphedema drainage. However, intermittent pneumatic compression performance and the effectiveness are often difficult to predict. This study presents a reduced-order numerical model of the interaction between the cardiovascular system and the intermittent pneumatic compression device. The effect that different intermittent pneumatic compression operating conditions have on the overall circulation is investigated. Our findings confirm (1) that an overall positive effect on hemodynamics can be obtained by properly applying the intermittent pneumatic compression device and (2) that using intermittent pneumatic compression for cardiocirculatory recovery is feasible in subjects affected by lower limb disease. © IMechE 2016.

  2. Fail-safe bidirectional valve driver

    NASA Technical Reports Server (NTRS)

    Fujimoto, H.

    1974-01-01

    Cross-coupled diodes are added to commonly used bidirectional valve driver circuit to protect circuit and power supply. Circuit may be used in systems requiring fail-safe bidirectional valve operation, particularly in chemical- and petroleum-processing control systems and computer-controlled hydraulic or pneumatic systems.

  3. Microvalve controlled multi-functional microfluidic chip for divisional cell co-culture.

    PubMed

    Li, Rui; Zhang, Xingjian; Lv, Xuefei; Geng, Lina; Li, Yongrui; Qin, Kuiwei; Deng, Yulin

    2017-12-15

    Pneumatic micro-valve controlled microfluidic chip provides precise fluidic control for cell manipulation. In this paper, a multi-functional microfluidic chip was designed for three separate experiments: 1. Different cell lines were dispensed and cultured; 2. Three transfected SH-SY5Y cells were introduced and treated with methyl-phenyl-pyridinium (MPP + ) as drug delivery mode; 3. Specific protection and interaction were observed among cell co-culture after nerve damage. The outcomes revealed the potential and practicability of our entire multi-functional pneumatic chip system on different cell biology applications. Copyright © 2017. Published by Elsevier Inc.

  4. A Study of Gas Economizing Pneumatic Cylinder

    NASA Astrophysics Data System (ADS)

    Li, T. C.; Wu, H. W.; Kuo, M. J.

    2006-10-01

    The pneumatic cylinder is the most typical actuator in the pneumatic equipment, and its mechanism is so simple that it is often used to operate point to point driving without the feedback loop in various automatic machines. But, the energy efficiency of pneumatic system is very poor compared with electrical systems and hydraulic systems. So, it is very important to discuss the energy saving for the pneumatic cylinder systems. In this thesis, we proposed three methods to apply the reduction in the air consumed for pneumatic cylinder systems. An air charge accumulator is used to absorb the exhausted compress air and a boost valve boosted the air to the higher pressure for used again. From the experiments, the direct used cylinder exhaust air may save about 40% of compress air.

  5. Microvalve-based microfluidic device for C. elegans manipulation

    NASA Astrophysics Data System (ADS)

    Johari, S.; Nock, V.; Alkaisi, M. M.; Wang, W.

    2017-09-01

    In this paper, we report on the integration of a force measurement application capable of continuously measuring the forces generated by C. elegans in motion with a series of controllable microvalves which have an additional ability to increase control over worm selection and manipulation. The three-layer device consists of a pneumatic layer at the top, and a fluidic layer at the bottom with a thin PDMS membrane which functions as a microvalve sandwiched in between. The pneumatic layer functions as valves, whose operation is controlled pneumatically. The fluidic layer contains of PDMS micropillars for resolving the worm force from the deflection of the cantilever-like pillars. The measured force is horizontal and equivalent to a point force acting at half of the pillar height. By carefully controlling the incorporated microvalves, the proposed device is able to select and direct worm movement and at the same time increase the number of force measurement results collected. The integration of the microvalve with the PDMS micropillar-based on chip system can be easily combined with existing screening and imaging systems and also has the capability to facilitate high-throughput screening of force patterns in C. elegans locomotion behaviour.

  6. A New Type of Motor: Pneumatic Step Motor

    PubMed Central

    Stoianovici, Dan; Patriciu, Alexandru; Petrisor, Doru; Mazilu, Dumitru; Kavoussi, Louis

    2011-01-01

    This paper presents a new type of pneumatic motor, a pneumatic step motor (PneuStep). Directional rotary motion of discrete displacement is achieved by sequentially pressurizing the three ports of the motor. Pulsed pressure waves are generated by a remote pneumatic distributor. The motor assembly includes a motor, gearhead, and incremental position encoder in a compact, central bore construction. A special electronic driver is used to control the new motor with electric stepper indexers and standard motion control cards. The motor accepts open-loop step operation as well as closed-loop control with position feedback from the enclosed sensor. A special control feature is implemented to adapt classic control algorithms to the new motor, and is experimentally validated. The speed performance of the motor degrades with the length of the pneumatic hoses between the distributor and motor. Experimental results are presented to reveal this behavior and set the expectation level. Nevertheless, the stepper achieves easily controllable precise motion unlike other pneumatic motors. The motor was designed to be compatible with magnetic resonance medical imaging equipment, for actuating an image-guided intervention robot, for medical applications. For this reason, the motors were entirely made of nonmagnetic and dielectric materials such as plastics, ceramics, and rubbers. Encoding was performed with fiber optics, so that the motors are electricity free, exclusively using pressure and light. PneuStep is readily applicable to other pneumatic or hydraulic precision-motion applications. PMID:21528106

  7. Pneumatic low-coherence interferometry otoscope to quantify tympanic membrane mobility and middle ear pressure.

    PubMed

    Won, Jungeun; Monroy, Guillermo L; Huang, Pin-Chieh; Dsouza, Roshan; Hill, Malcolm C; Novak, Michael A; Porter, Ryan G; Chaney, Eric; Barkalifa, Ronit; Boppart, Stephen A

    2018-02-01

    Pneumatic otoscopy to assess the mobility of the tympanic membrane (TM) is a highly recommended diagnostic method of otitis media (OM), a widespread middle ear infection characterized by the fluid accumulation in the middle ear. Nonetheless, limited depth perception and subjective interpretation of small TM displacements have challenged the appropriate and efficient examination of TM dynamics experienced during OM. In this paper, a pneumatic otoscope integrated with low coherence interferometry (LCI) was adapted with a controlled pressure-generating system to record the pneumatic response of the TM and to estimate middle ear pressure (MEP). Forty-two ears diagnosed as normal (n = 25), with OM (n = 10), or associated with an upper respiratory infection (URI) (n = 7) were imaged with a pneumatic LCI otoscope with an axial, transverse, and temporal resolution of 6 µm, 20 µm, and 1 msec, respectively. The TM displacement under pneumatic pressure transients (a duration of 0.5 sec with an intensity of ± 150 daPa) was measured to compute two metrics (compliance and amplitude ratio). These metrics were correlated with peak acoustic admittance and MEP from tympanometry and statistically compared via Welch's t- test. As a result, the compliance represents pneumatic TM mobility, and the amplitude ratio estimates MEP. The presence of a middle ear effusion (MEE) significantly decreased compliance (p<0.001). The amplitude ratio of the OM group was statistically less than that of the normal group (p<0.01), indicating positive MEP. Unlike tympanometry, pneumatic LCI otoscopy quantifies TM mobility as well as MEP regardless of MEE presence. With combined benefits of pneumatic otoscopy and tympanometry, pneumatic LCI otoscopy may provide new quantitative metrics for understanding TM dynamics and diagnosing OM.

  8. Pneumatic low-coherence interferometry otoscope to quantify tympanic membrane mobility and middle ear pressure

    PubMed Central

    Won, Jungeun; Monroy, Guillermo L.; Huang, Pin-Chieh; Dsouza, Roshan; Hill, Malcolm C.; Novak, Michael A.; Porter, Ryan G.; Chaney, Eric; Barkalifa, Ronit; Boppart, Stephen A.

    2018-01-01

    Pneumatic otoscopy to assess the mobility of the tympanic membrane (TM) is a highly recommended diagnostic method of otitis media (OM), a widespread middle ear infection characterized by the fluid accumulation in the middle ear. Nonetheless, limited depth perception and subjective interpretation of small TM displacements have challenged the appropriate and efficient examination of TM dynamics experienced during OM. In this paper, a pneumatic otoscope integrated with low coherence interferometry (LCI) was adapted with a controlled pressure-generating system to record the pneumatic response of the TM and to estimate middle ear pressure (MEP). Forty-two ears diagnosed as normal (n = 25), with OM (n = 10), or associated with an upper respiratory infection (URI) (n = 7) were imaged with a pneumatic LCI otoscope with an axial, transverse, and temporal resolution of 6 µm, 20 µm, and 1 msec, respectively. The TM displacement under pneumatic pressure transients (a duration of 0.5 sec with an intensity of ± 150 daPa) was measured to compute two metrics (compliance and amplitude ratio). These metrics were correlated with peak acoustic admittance and MEP from tympanometry and statistically compared via Welch’s t-test. As a result, the compliance represents pneumatic TM mobility, and the amplitude ratio estimates MEP. The presence of a middle ear effusion (MEE) significantly decreased compliance (p<0.001). The amplitude ratio of the OM group was statistically less than that of the normal group (p<0.01), indicating positive MEP. Unlike tympanometry, pneumatic LCI otoscopy quantifies TM mobility as well as MEP regardless of MEE presence. With combined benefits of pneumatic otoscopy and tympanometry, pneumatic LCI otoscopy may provide new quantitative metrics for understanding TM dynamics and diagnosing OM. PMID:29552381

  9. Controllable pneumatic generator based on the catalytic decomposition of hydrogen peroxide

    NASA Astrophysics Data System (ADS)

    Kim, Kyung-Rok; Kim, Kyung-Soo; Kim, Soohyun

    2014-07-01

    This paper presents a novel compact and controllable pneumatic generator that uses hydrogen peroxide decomposition. A fuel micro-injector using a piston-pump mechanism is devised and tested to control the chemical decomposition rate. By controlling the injection rate, the feedback controller maintains the pressure of the gas reservoir at a desired pressure level. Thermodynamic analysis and experiments are performed to demonstrate the feasibility of the proposed pneumatic generator. Using a prototype of the pneumatic generator, it takes 6 s to reach 3.5 bars with a reservoir volume of 200 ml at the room temperature, which is sufficiently rapid and effective to maintain the repetitive lifting of a 1 kg mass.

  10. Controllable pneumatic generator based on the catalytic decomposition of hydrogen peroxide.

    PubMed

    Kim, Kyung-Rok; Kim, Kyung-Soo; Kim, Soohyun

    2014-07-01

    This paper presents a novel compact and controllable pneumatic generator that uses hydrogen peroxide decomposition. A fuel micro-injector using a piston-pump mechanism is devised and tested to control the chemical decomposition rate. By controlling the injection rate, the feedback controller maintains the pressure of the gas reservoir at a desired pressure level. Thermodynamic analysis and experiments are performed to demonstrate the feasibility of the proposed pneumatic generator. Using a prototype of the pneumatic generator, it takes 6 s to reach 3.5 bars with a reservoir volume of 200 ml at the room temperature, which is sufficiently rapid and effective to maintain the repetitive lifting of a 1 kg mass.

  11. Control system for an artificial heart

    NASA Technical Reports Server (NTRS)

    Gebben, V. D.; Webb, J. A., Jr.

    1970-01-01

    Inexpensive industrial pneumatic components are combined to produce control system to drive sac-type heart-assistance blood pump with controlled pulsatile pressure that makes pump rate of flow sensitive to venous /atrial/ pressure, while stroke is centered about set operating point and pump is synchronized with natural heart.

  12. Using cognitive task analysis to inform issues in human systems integration in railroad operations

    DOT National Transportation Integrated Search

    2013-05-23

    U.S. Railroad operations are undergoing rapid changes involving the introduction of new technologies such as positive train control (PTC), energy management systems (EMS), and electronically controlled pneumatic (ECP) brakes in the locomotive cab. To...

  13. Vibration and recoil control of pneumatic hammers. [by air flow pressure regulation

    NASA Technical Reports Server (NTRS)

    Constantinescu, I. N.; Darabont, A. V.

    1974-01-01

    Vibration sources are described for pneumatic hammers used in the mining industry (pick hammers), in boiler shops (riveting hammers), etc., bringing to light the fact that the principal vibration source is the variation in air pressure inside the cylinder. The present state of the art of vibration control of pneumatic hammers as it is practiced abroad, and the solutions adopted for this purpose, are discussed. A new type of pneumatic hammer with a low noise and vibration level is presented.

  14. 46 CFR 128.240 - Hydraulic or pneumatic power and control-materials and pressure design.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... Hydraulic or pneumatic power and control—materials and pressure design. (a) Each standard piping component... 46 Shipping 4 2014-10-01 2014-10-01 false Hydraulic or pneumatic power and control-materials and pressure design. 128.240 Section 128.240 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED...

  15. 46 CFR 128.240 - Hydraulic or pneumatic power and control-materials and pressure design.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... Hydraulic or pneumatic power and control—materials and pressure design. (a) Each standard piping component... 46 Shipping 4 2011-10-01 2011-10-01 false Hydraulic or pneumatic power and control-materials and pressure design. 128.240 Section 128.240 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED...

  16. 46 CFR 128.240 - Hydraulic or pneumatic power and control-materials and pressure design.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... Hydraulic or pneumatic power and control—materials and pressure design. (a) Each standard piping component... 46 Shipping 4 2012-10-01 2012-10-01 false Hydraulic or pneumatic power and control-materials and pressure design. 128.240 Section 128.240 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED...

  17. 46 CFR 128.240 - Hydraulic or pneumatic power and control-materials and pressure design.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... Hydraulic or pneumatic power and control—materials and pressure design. (a) Each standard piping component... 46 Shipping 4 2013-10-01 2013-10-01 false Hydraulic or pneumatic power and control-materials and pressure design. 128.240 Section 128.240 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED...

  18. 46 CFR 128.240 - Hydraulic or pneumatic power and control-materials and pressure design.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... Hydraulic or pneumatic power and control—materials and pressure design. (a) Each standard piping component... 46 Shipping 4 2010-10-01 2010-10-01 false Hydraulic or pneumatic power and control-materials and pressure design. 128.240 Section 128.240 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED...

  19. Prognostics for Ground Support Systems: Case Study on Pneumatic Valves

    NASA Technical Reports Server (NTRS)

    Daigle, Matthew; Goebel, Kai

    2011-01-01

    Prognostics technologies determine the health (or damage) state of a component or sub-system, and make end of life (EOL) and remaining useful life (RUL) predictions. Such information enables system operators to make informed maintenance decisions and streamline operational and mission-level activities. We develop a model-based prognostics methodology for pneumatic valves used in ground support equipment for cryogenic propellant loading operations. These valves are used to control the flow of propellant, so failures may have a significant impact on launch availability. Therefore, correctly predicting when valves will fail enables timely maintenance that avoids launch delays and aborts. The approach utilizes mathematical models describing the underlying physics of valve degradation, and, employing the particle filtering algorithm for joint state-parameter estimation, determines the health state of the valve and the rate of damage progression, from which EOL and RUL predictions are made. We develop a prototype user interface for valve prognostics, and demonstrate the prognostics approach using historical pneumatic valve data from the Space Shuttle refueling system.

  20. Hemolysis associated with pneumatic tube system transport for blood samples

    PubMed Central

    Kara, Hasan; Bayir, Aysegul; Ak, Ahmet; Degirmenci, Selim; Akinci, Murat; Agacayak, Ahmet; Marcil, Emine; Azap, Melih

    2014-01-01

    Objective: The frequency of hemolysis of blood samples may be increased by transport in a pneumatic tube system. The purpose of this study was to evaluate the effect of pneumatic tube system transport on hemolysis of blood samples. Methods: Blood samples were transported from the emergency department to the hospital laboratory manually by hospital staff (49 patients) or with a pneumatic tube system (53 patients). The hemolysis index and serum chemistry studies were performed on the blood samples and compared between the different methods of transport. Results: The blood samples that were transported by the pneumatic tube system had a greater frequency of hemolysis and greater mean serum potassium and median creatinine, aspartate aminotransferase, and lactate dehydrogenase levels than samples transported manually. Conclusion: Blood samples transported from the emergency department to the hospital laboratory by a pneumatic tube system may have a greater frequency of hemolysis than samples transported manually. This may necessitate repeat phlebotomy and cause a delay in completing the laboratory analysis. PMID:24639830

  1. Five-DOF innovative linear MagLev slider to account for pitch, tilt and load uncertainty

    NASA Astrophysics Data System (ADS)

    Kao, Yi-Ming; Tsai, Nan-Chyuan; Chiu, Hsin-Lin

    2017-02-01

    This paper is focused at position deviation regulation upon a slider by Fuzzy Sliding Mode Control (FSMC). Five Degrees Of Freedom (DOF) of position deviation are required to be regulated except for the direction (i.e., X-axis) in which the slider moves forward and backward. Totally 8 sets of Magnetic Actuators (MAs) and an Electro-Pneumatic Transducer (EPT) are employed to drive the slider carrying loads under the commands of FSMC. EPT is applied to adjust the pressure of compressed air to counterbalance the weight of slider itself. At first, the system dynamic model of slider, including load uncertainty and load position uncertainty, is established. Intensive computer simulations are undertaken to verify the validity of proposed control strategy. Finally, a prototype of realistic slider position deviation regulation system is successfully built up. According to the experiments by cooperation of pneumatic and magnetic control, the actual linear position deviations of slider can be regulated within ±8 μm and angular position deviations within ±1 mini-degrees. From the viewpoint of energy consumption, the applied currents to 8 sets of MAs are all below 1.2 A. To sum up, the closed-loop levitation system by cooperation of pneumatic and magnetic control is capable to account for load uncertainty and uncertainty of the standing position of load to be carried.

  2. Survey of aircraft electrical power systems

    NASA Technical Reports Server (NTRS)

    Lee, C. H.; Brandner, J. J.

    1972-01-01

    Areas investigated include: (1) load analysis; (2) power distribution, conversion techniques and generation; (3) design criteria and performance capabilities of hydraulic and pneumatic systems; (4) system control and protection methods; (5) component and heat transfer systems cooling; and (6) electrical system reliability.

  3. Development of a Pneumatic Robot for MRI-guided Transperineal Prostate Biopsy and Brachytherapy: New Approaches

    PubMed Central

    Song, Sang-Eun; Cho, Nathan B.; Fischer, Gregory; Hata, Nobuhito; Tempany, Clare; Fichtinger, Gabor; Iordachita, Iulian

    2011-01-01

    Magnetic Resonance Imaging (MRI) guided prostate biopsy and brachytherapy has been introduced in order to enhance the cancer detection and treatment. For the accurate needle positioning, a number of robotic assistants have been developed. However, problems exist due to the strong magnetic field and limited workspace. Pneumatically actuated robots have shown the minimum distraction in the environment but the confined workspace limits optimal robot design and thus controllability is often poor. To overcome the problem, a simple external damping mechanism using timing belts was sought and a 1-DOF mechanism test result indicated sufficient positioning accuracy. Based on the damping mechanism and modular system design approach, a new workspace-optimized 4-DOF parallel robot was developed for the MRI-guided prostate biopsy and brachytherapy. A preliminary evaluation of the robot was conducted using previously developed pneumatic controller and satisfying results were obtained. PMID:21399734

  4. Pneumatic Compression, But Not Exercise, Can Avoid Intradialytic Hypotension: A Randomized Trial.

    PubMed

    Álvares, Valeria R C; Ramos, Camila D; Pereira, Benedito J; Pinto, Ana Lucia; Moysés, Rosa M A; Gualano, Bruno; Elias, Rosilene M

    2017-01-01

    Conventional hemodialysis (HD) is associated with dialysis-induced hypotension (DIH) and ineffective phosphate removal. As the main source of extracellular fluid removed during HD are the legs, we sought to reduce DIH and increase phosphate removal by using cycling and pneumatic compression, which would potentially provide higher venous return, preserving central blood flow and also offering more phosphate to the dialyzer. We evaluated 21 patients in a randomized crossover fashion in which each patient underwent 3 different HD: control; cycling exercise during the first 60 min; and pneumatic compression during the first 60 min. Data obtained included bioelectrical impedance, hourly blood pressure measurement, biochemical parameters, and direct quantification of phosphate through the dialysate. DIH was defined as a drop in mean arterial pressure (MAP) ≥20 mm Hg. There was no difference in the ultrafiltration rate (p = 0.628), delta weight (p = 0.415), delta of total, intra and extracellular body water among the control, cycling, and pneumatic compression (p = 0.209, p = 0.348, and p = 0.467 respectively). Delta MAP was less changed by pneumatic compression when compared to control, cycling, and pneumatic compression respectively (-4.7 [-17.2, 8.2], -4.7 [-20.5, -0.2], and -2.3 [-8.1, 9.0] mm Hg; p = 0.021). DIH occurred in 43, 38, and 24% of patients in control, cycling, and pneumatic compression respectively (p = 0.014). Phosphate removal did not increase in any intervention (p = 0.486). Higher phosphate removal was dependent on ultrafiltration, pre dialysis serum phosphate, and higher parathyroid hormone. Pneumatic compression during the first hour of dialysis was associated with less DIH, albeit there was no effect on fluid parameters. Neither exercise nor pneumatic compression increased phosphate removal. © 2017 S. Karger AG, Basel.

  5. Environmental sustainability comparison of a hypothetical pneumatic waste collection system and a door-to-door system.

    PubMed

    Punkkinen, Henna; Merta, Elina; Teerioja, Nea; Moliis, Katja; Kuvaja, Eveliina

    2012-10-01

    Waste collection is one of the life cycle phases that influence the environmental sustainability of waste management. Pneumatic waste collection systems represent a new way of arranging waste collection in densely populated urban areas. However, limited information is available on the environmental impacts of this system. In this study, we compare the environmental sustainability of conventional door-to-door waste collection with its hypothetical pneumatic alternative. Furthermore, we analyse whether the size of the hypothetical pneumatic system, or the number of waste fractions included, have an impact on the results. Environmental loads are calculated for a hypothetical pneumatic waste collection system modelled on an existing dense urban area in Helsinki, Finland, and the results are compared to those of the prevailing, container-based, door-to-door waste collection system. The evaluation method used is the life-cycle inventory (LCI). In this study, we report the atmospheric emissions of greenhouse gases (GHG), SO(2) and NO(x). The results indicate that replacing the prevailing system with stationary pneumatic waste collection in an existing urban infrastructure would increase total air emissions. Locally, in the waste collection area, emissions would nonetheless diminish, as collection traffic decreases. While the electricity consumption of the hypothetical pneumatic system and the origin of electricity have a significant bearing on the results, emissions due to manufacturing the system's components prove decisive. Copyright © 2012 Elsevier Ltd. All rights reserved.

  6. Web-Based Learning and Instruction Support System for Pneumatics

    ERIC Educational Resources Information Center

    Yen, Chiaming; Li, Wu-Jeng

    2003-01-01

    This research presents a Web-based learning and instructional system for Pneumatics. The system includes course material, remote data acquisition modules, and a pneumatic laboratory set. The course material is in the HTML format accompanied with text, still and animated images, simulation programs, and computer aided design tools. The data…

  7. Adding the 'heart' to hanging drop networks for microphysiological multi-tissue experiments.

    PubMed

    Rismani Yazdi, Saeed; Shadmani, Amir; Bürgel, Sebastian C; Misun, Patrick M; Hierlemann, Andreas; Frey, Olivier

    2015-11-07

    Microfluidic hanging-drop networks enable culturing and analysis of 3D microtissue spheroids derived from different cell types under controlled perfusion and investigating inter-tissue communication in multi-tissue formats. In this paper we introduce a compact on-chip pumping approach for flow control in hanging-drop networks. The pump includes one pneumatic chamber located directly above one of the hanging drops and uses the surface tension at the liquid-air-interface for flow actuation. Control of the pneumatic protocol provides a wide range of unidirectional pulsatile and continuous flow profiles. With the proposed concept several independent hanging-drop networks can be operated in parallel with only one single pneumatic actuation line at high fidelity. Closed-loop medium circulation between different organ models for multi-tissue formats and multiple simultaneous assays in parallel are possible. Finally, we implemented a real-time feedback control-loop of the pump actuation based on the beating of a human iPS-derived cardiac microtissue cultured in the same system. This configuration allows for simulating physiological effects on the heart and their impact on flow circulation between the organ models on chip.

  8. New control design principles based on measured performance and energy analysis of HVAC (Heating, Ventilating, and Air-Conditioning) systems

    NASA Astrophysics Data System (ADS)

    Hittle, D. C.; Johnson, D. L.

    1985-01-01

    This report is one of a series on the development of heating, ventilating, and air-conditioning (HVAC) control systems that are simple, efficient, reliable, maintainable, and well-documented. This report identifies major problems associated with three currently used HVAC control systems. It also describes the development of a retrofit control system applicable to military buildings that will allow easy identification of component failures, facilitate repair, and minimize system failures. Evaluation of currently used controls showed that pneumatic temperature control equipment requires a very clean source of supply air and is also not very accurate. Pneumatic, rather than electronic, actuators should be used because they are cheaper and require less maintenance. Thermistor temperature detectors should not be used for HVAC applications because they require frequent calibration. It was found that enthalpy economy cycles cannot be used for control because the humidity sensors required for their use are prone to rapid drift, inaccurate, and hard to calibrate in the field. Performance of control systems greatly affects HVAC operating costs. Significant savings can be achieved if proportional-plus-integral control schemes are used. Use of the retrofit prototype control panel developed in this study on variable-air-volume systems should provide significant energy cost savings, improve comfort and reliability, and reduce maintenance costs.

  9. A pneumatic Bionic Voice prosthesis-Pre-clinical trials of controlling the voice onset and offset.

    PubMed

    Ahmadi, Farzaneh; Noorian, Farzad; Novakovic, Daniel; van Schaik, André

    2018-01-01

    Despite emergent progress in many fields of bionics, a functional Bionic Voice prosthesis for laryngectomy patients (larynx amputees) has not yet been achieved, leading to a lifetime of vocal disability for these patients. This study introduces a novel framework of Pneumatic Bionic Voice Prostheses as an electronic adaptation of the Pneumatic Artificial Larynx (PAL) device. The PAL is a non-invasive mechanical voice source, driven exclusively by respiration with an exceptionally high voice quality, comparable to the existing gold standard of Tracheoesophageal (TE) voice prosthesis. Following PAL design closely as the reference, Pneumatic Bionic Voice Prostheses seem to have a strong potential to substitute the existing gold standard by generating a similar voice quality while remaining non-invasive and non-surgical. This paper designs the first Pneumatic Bionic Voice prosthesis and evaluates its onset and offset control against the PAL device through pre-clinical trials on one laryngectomy patient. The evaluation on a database of more than five hours of continuous/isolated speech recordings shows a close match between the onset/offset control of the Pneumatic Bionic Voice and the PAL with an accuracy of 98.45 ±0.54%. When implemented in real-time, the Pneumatic Bionic Voice prosthesis controller has an average onset/offset delay of 10 milliseconds compared to the PAL. Hence it addresses a major disadvantage of previous electronic voice prostheses, including myoelectric Bionic Voice, in meeting the short time-frames of controlling the onset/offset of the voice in continuous speech.

  10. A pneumatic Bionic Voice prosthesis—Pre-clinical trials of controlling the voice onset and offset

    PubMed Central

    Noorian, Farzad; Novakovic, Daniel; van Schaik, André

    2018-01-01

    Despite emergent progress in many fields of bionics, a functional Bionic Voice prosthesis for laryngectomy patients (larynx amputees) has not yet been achieved, leading to a lifetime of vocal disability for these patients. This study introduces a novel framework of Pneumatic Bionic Voice Prostheses as an electronic adaptation of the Pneumatic Artificial Larynx (PAL) device. The PAL is a non-invasive mechanical voice source, driven exclusively by respiration with an exceptionally high voice quality, comparable to the existing gold standard of Tracheoesophageal (TE) voice prosthesis. Following PAL design closely as the reference, Pneumatic Bionic Voice Prostheses seem to have a strong potential to substitute the existing gold standard by generating a similar voice quality while remaining non-invasive and non-surgical. This paper designs the first Pneumatic Bionic Voice prosthesis and evaluates its onset and offset control against the PAL device through pre-clinical trials on one laryngectomy patient. The evaluation on a database of more than five hours of continuous/isolated speech recordings shows a close match between the onset/offset control of the Pneumatic Bionic Voice and the PAL with an accuracy of 98.45 ±0.54%. When implemented in real-time, the Pneumatic Bionic Voice prosthesis controller has an average onset/offset delay of 10 milliseconds compared to the PAL. Hence it addresses a major disadvantage of previous electronic voice prostheses, including myoelectric Bionic Voice, in meeting the short time-frames of controlling the onset/offset of the voice in continuous speech. PMID:29466455

  11. Optimal pressure regulation of the pneumatic ventricular assist device with bellows-type driver.

    PubMed

    Lee, Jung Joo; Kim, Bum Soo; Choi, Jaesoon; Choi, Hyuk; Ahn, Chi Bum; Nam, Kyoung Won; Jeong, Gi Seok; Lim, Choon Hak; Son, Ho Sung; Sun, Kyung

    2009-08-01

    The bellows-type pneumatic ventricular assist device (VAD) generates pneumatic pressure with compression of bellows instead of using an air compressor. This VAD driver has a small volume that is suitable for portable devices. However, improper pneumatic pressure setup can not only cause a lack of adequate flow generation, but also cause durability problems. In this study, a pneumatic pressure regulation system for optimal operation of the bellows-type VAD has been developed. The optimal pneumatic pressure conditions according to various afterload conditions aiming for optimal flow rates were investigated, and an afterload estimation algorithm was developed. The developed regulation system, which consists of a pressure sensor and a two-way solenoid valve, estimates the current afterload and regulates the pneumatic pressure to the optimal point for the current afterload condition. Experiments were performed in a mock circulation system. The afterload estimation algorithm showed sufficient performance with the standard deviation of error, 8.8 mm Hg. The flow rate could be stably regulated with a developed system under various afterload conditions. The shortcoming of a bellows-type VAD could be handled with this simple pressure regulation system.

  12. Control system for the 2nd generation Berkeley AutoMounters (BAM2) at GM/CA CAT macromolecular crystallography beamlines

    PubMed Central

    Makarov, O.; Hilgart, M.; Ogata, C.; Pothineni, S.; Cork, C.

    2011-01-01

    GM/CA CAT at Sector 23 of the Advanced Photon Source (APS) is an NIH funded facility for crystallographic structure determination of biological macromolecules by X-ray diffraction. A second generation Berkeley automounter is being integrated into the beamline control system at the 23-BM experimental station. This new device replaces the previous all-pneumatic gripper motions with a combination of pneumatics and XYZ motorized linear stages. The latter adds a higher degree of flexibility to the robot including auto-alignment capability, accommodation of a larger capacity sample Dewar of arbitrary shape, and support for advanced operations such as crystal washing, while preserving the overall simplicity and efficiency of the Berkeley automounter design. PMID:21822343

  13. Haptic control of a pneumatic muscle actuator to provide resistance for simulated isokinetic exercise; part II: control development and testing.

    PubMed

    Hall, Kara L; Phillips, Chandler A; Reynolds, David B; Mohler, Stanley R; Rogers, Dana B; Neidhard-Doll, Amy T

    2015-01-01

    Pneumatic muscle actuators (PMAs) have a high power to weight ratio and possess unique characteristics which make them ideal actuators for applications involving human interaction. PMAs are difficult to control due to nonlinear dynamics, presenting challenges in system implementation. Despite these challenges, PMAs have great potential as a source of resistance for strength training and rehabilitation. The objective of this work was to control a PMA for use in isokinetic exercise, potentially benefiting anyone in need of optimal strength training through a joint's range of motion. The controller, based on an inverse three-element phenomenological model and adaptive nonlinear control, allows the system to operate as a type of haptic device. A human quadriceps dynamic simulator was developed (as described in Part I of this work) so that control effectiveness and accommodation could be tested prior to human implementation. Tracking error results indicate that the control system is effective at producing PMA displacement and resistance necessary for a scaled, simulated neuromuscular actuator to maintain low-velocity isokinetic movement during simulated concentric and eccentric knee extension.

  14. A comparison between electromechanical and pneumatic-controlled knee simulators for the investigation of wear of total knee replacements.

    PubMed

    Abdelgaied, Abdellatif; Fisher, John; Jennings, Louise M

    2017-07-01

    More robust preclinical experimental wear simulation methods are required in order to simulate a wider range of activities, observed in different patient populations such as younger more active patients, as well as to fully meet and be capable of going well beyond the existing requirements of the relevant international standards. A new six-station electromechanically driven simulator (Simulation Solutions, UK) with five fully independently controlled axes of articulation for each station, capable of replicating deep knee bending as well as other adverse conditions, which can be operated in either force or displacement control with improved input kinematic following, has been developed to meet these requirements. This study investigated the wear of a fixed-bearing total knee replacement using this electromechanically driven fully independent knee simulator and compared it to previous data from a predominantly pneumatically controlled simulator in which each station was not fully independently controlled. In addition, the kinematic performance and the repeatability of the simulators have been investigated and compared to the international standard requirements. The wear rates from the electromechanical and pneumatic knee simulators were not significantly different, with wear rates of 2.6 ± 0.9 and 2.7 ± 0.9 mm 3 /million cycles (MC; mean ± 95% confidence interval, p = 0.99) and 5.4 ± 1.4 and 6.7 ± 1.5 mm 3 /MC (mean ± 95 confidence interval, p = 0.54) from the electromechanical and pneumatic simulators under intermediate levels (maximum 5 mm) and high levels (maximum 10 mm) of anterior-posterior displacements, respectively. However, the output kinematic profiles of the control system, which drive the motion of the simulator, followed the input kinematic profiles more closely on the electromechanical simulator than the pneumatic simulator. In addition, the electromechanical simulator was capable of following kinematic and loading input cycles within the tolerances of the international standard requirements (ISO 14243-3). The new-generation electromechanical knee simulator with fully independent control has the potential to be used for a much wider range of kinematic conditions, including high-flexion and other severe conditions, due to its improved capability and performance in comparison to the previously used pneumatic-controlled simulators.

  15. A comparison between electromechanical and pneumatic-controlled knee simulators for the investigation of wear of total knee replacements

    PubMed Central

    Abdelgaied, Abdellatif; Fisher, John; Jennings, Louise M

    2017-01-01

    More robust preclinical experimental wear simulation methods are required in order to simulate a wider range of activities, observed in different patient populations such as younger more active patients, as well as to fully meet and be capable of going well beyond the existing requirements of the relevant international standards. A new six-station electromechanically driven simulator (Simulation Solutions, UK) with five fully independently controlled axes of articulation for each station, capable of replicating deep knee bending as well as other adverse conditions, which can be operated in either force or displacement control with improved input kinematic following, has been developed to meet these requirements. This study investigated the wear of a fixed-bearing total knee replacement using this electromechanically driven fully independent knee simulator and compared it to previous data from a predominantly pneumatically controlled simulator in which each station was not fully independently controlled. In addition, the kinematic performance and the repeatability of the simulators have been investigated and compared to the international standard requirements. The wear rates from the electromechanical and pneumatic knee simulators were not significantly different, with wear rates of 2.6 ± 0.9 and 2.7 ± 0.9 mm3/million cycles (MC; mean ± 95% confidence interval, p = 0.99) and 5.4 ± 1.4 and 6.7 ± 1.5 mm3/MC (mean ± 95 confidence interval, p = 0.54) from the electromechanical and pneumatic simulators under intermediate levels (maximum 5 mm) and high levels (maximum 10 mm) of anterior–posterior displacements, respectively. However, the output kinematic profiles of the control system, which drive the motion of the simulator, followed the input kinematic profiles more closely on the electromechanical simulator than the pneumatic simulator. In addition, the electromechanical simulator was capable of following kinematic and loading input cycles within the tolerances of the international standard requirements (ISO 14243-3). The new-generation electromechanical knee simulator with fully independent control has the potential to be used for a much wider range of kinematic conditions, including high-flexion and other severe conditions, due to its improved capability and performance in comparison to the previously used pneumatic-controlled simulators. PMID:28661228

  16. Method for improving the fuel efficiency of a gas turbine engine

    NASA Technical Reports Server (NTRS)

    Coffinberry, G. A. (Inventor)

    1985-01-01

    An energy recovery system is provided for an aircraft gas turbine engine of the type in which some of the pneumatic energy developed by the engine is made available to support systems such as an environmental control system. In one such energy recovery system, some of the pneumatic energy made available to but not utilized by the support system is utilized to heat the engine fuel immediately prior to the consumption of the fuel by the engine. Some of the recovered energy may also be utilized to heat the fuel in the fuel tanks. Provision is made for multiengine applications wherein energy recovered from one engine may be utilized by another one of the engines or systems associated therewith.

  17. Apparatus for improving the fuel efficiency of a gas turbine engine

    NASA Technical Reports Server (NTRS)

    Coffinberry, G. A. (Inventor)

    1983-01-01

    An energy recovery system is provided for an aircraft gas turbine engine of the type in which some of the pneumatic energy developed by the engine is made available to support systems such as an environmental control system. In one such energy recovery system, some of the pneumatic energy made available to but not utilized by the support system is utilized to heat the engine fuel immediately prior to the consumption of the fuel by the engine. Some of the recovered energy may also be utilized to heat the fuel in the fuel tanks. Provision is made for multiengine applications wherein energy recovered from one engine may be utilized by another one of the engines or systems associated therewith.

  18. Integrated direct/indirect adaptive robust motion trajectory tracking control of pneumatic cylinders

    NASA Astrophysics Data System (ADS)

    Meng, Deyuan; Tao, Guoliang; Zhu, Xiaocong

    2013-09-01

    This paper studies the precision motion trajectory tracking control of a pneumatic cylinder driven by a proportional-directional control valve. An integrated direct/indirect adaptive robust controller is proposed. The controller employs a physical model based indirect-type parameter estimation to obtain reliable estimates of unknown model parameters, and utilises a robust control method with dynamic compensation type fast adaptation to attenuate the effects of parameter estimation errors, unmodelled dynamics and disturbances. Due to the use of projection mapping, the robust control law and the parameter adaption algorithm can be designed separately. Since the system model uncertainties are unmatched, the recursive backstepping technology is adopted to design the robust control law. Extensive comparative experimental results are presented to illustrate the effectiveness of the proposed controller and its performance robustness to parameter variations and sudden disturbances.

  19. Design and control of a novel gastroscope intervention mechanism with circumferentially pneumatic-driven clamping function.

    PubMed

    Li, Yanmin; Liu, Hao; Hao, Siwen; Li, Hongyi; Han, Jianda; Yang, Yunsheng

    2017-03-01

    Robot-assisted manipulation is promising for solving problems such as understaffing and the risk of infection in gastro-intestinal endoscopy. However, the commonly used friction rollers in few existing systems have a potential risk of deforming flexible endoscopes for non-uniform clamping. This paper presents a robotic system for a standard flexible endoscope and focuses on a novel gastroscope intervention mechanism (GIM), which provides circumferentially uniform clamping with an airbag. The GIM works with a relay-on mechanism in a way similar to manual operation. The shear stiffness of airbag and the critical slipping force (CSF) were analysed to determine the parameters of the airbag. A fuzzy PID controller was employed to realize a fast response and high accuracy of pneumatic actuation. Experiments were performed to evaluate the accuracy, stiffness and CSF. In vitro and in vivo animal experiments were also carried out. The GIM realized an accuracy of 0.025 ± 0.2 mm and -0.03 ± 0.25° for push-pull and rotation without delivery resistance. Under < 10 N delivery resistance, the error caused by the airbag stiffness was < 0.24 mm. A quadratic polynomial could be used to describe the relationship between the CSF and pneumatic pressure. The novel GIM could effectively deliver gastroscopes. The pneumatic-driven clamping method proposed could protect the gastroscope by circumferentially uniform clamping force and the CSF could be properly controlled to guarantee operating safety. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  20. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Miller, Benjamin, E-mail: BenjaminMiller@nyc.rr.com; Spertus, Juliette, E-mail: Juliette.Spertus@gmail.com; Kamga, Camille, E-mail: CKamga@UTRC2.org

    Highlights: • Pneumatic and truck collection were compared in three New York City locations. • Relative costs, energy use, and greenhouse gas emissions varied significantly. • Variations were due to location-specific factors (e.g., route density, truck type). • Under appropriate conditions, pneumatic collection reduces TMT, BTU, and GHG. • Pneumatic capex may be offset by operating savings and externality benefits. - Abstract: Truck-based collection of municipal solid waste imposes significant negative externalities on cities and constrains the efficiency of separate collection of recyclables and organics and of unit-price-based waste-reduction systems. In recent decades, hundreds of municipal-scale pneumatic collection systems havemore » been installed in Europe and Asia. Relatively few prior studies have compared the economic or environmental impacts of these systems to those of truck collection. A critical factor to consider when making this comparison is the extent to which the findings reflect the specific geographic, demographic, and operational characteristics of the systems considered. This paper is based on three case studies that consider the specific characteristics of three locations, comparing pneumatic systems with conventional collection on the basis of actual waste tonnages, composition, sources, collection routes, truck trips, and facility locations. In one case, alternative upgrades to an existing pneumatic system are compared to a potential truck-collection operation. In the other cases, existing truck operations are compared to proposed pneumatic systems which, to reduce capital costs, would be installed without new trenching or tunneling through the use of existing linear infrastructure. For the two proposed retrofit pneumatic systems, up to 48,000 truck kilometers travelled would be avoided and energy use would be reduced by up to 60% at an incremental cost of up to $400,000 USD per year over the total operating-plus-capital cost of conventional collection. In the location where a greenfield pneumatic system is already in operation, truck collection would be both less expensive and more energy-efficient than pneumatic collection. The results demonstrate that local geographic, demographic, and operational conditions play a decisive role in determining whether pneumatic collection will reduce energy requirements, produce more or fewer greenhouse gas emissions, and cost more or less over the long-term. These findings point to the local factors that will determine the relative economic and environmental costs and benefits in specific situations.« less

  1. 49 CFR 232.601 - Scope.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... TRANSPORTATION BRAKE SYSTEM SAFETY STANDARDS FOR FREIGHT AND OTHER NON-PASSENGER TRAINS AND EQUIPMENT; END-OF-TRAIN DEVICES Electronically Controlled Pneumatic (ECP) Braking Systems § 232.601 Scope. This subpart... systems. This subpart also contains specific exceptions from various requirements contained in this part...

  2. Pneumatic Flap Performance for a 2D Circulation Control Airfoil, Steady and Pulsed

    NASA Technical Reports Server (NTRS)

    Jones, Gregory S.

    2005-01-01

    Circulation Control technologies have been around for 65 years, and have been successfully demonstrated in laboratories and flight vehicles alike, yet there are few production aircraft flying today that implement these advances. Circulation Control techniques may have been overlooked due to perceived unfavorable trade offs of mass flow, pitching moment, cruise drag, noise, etc. Improvements in certain aspects of Circulation Control technology are the focus of this paper. This report will describe airfoil and blown high lift concepts that also address cruise drag reduction and reductions in mass flow through the use of pulsed pneumatic blowing on a Coanda surface. Pulsed concepts demonstrate significant reductions in mass flow requirements cor Circulation Control, as well as cruise drag concepts that equal or exceed conventional airfoil systems.

  3. Design and characterization of a biologically inspired quasi-passive prosthetic ankle-foot.

    PubMed

    Mooney, Luke M; Lai, Cara H; Rouse, Elliott J

    2014-01-01

    By design, commonly worn energy storage and release (ESR) prosthetic feet cannot provide biologically realistic ankle joint torque and angle profiles during walking. Additionally, their anthropomorphic, cantilever architecture causes their mechanical stiffness to decrease throughout the stance phase of walking, opposing the known trend of the biological ankle. In this study, the design of a quasi-passive pneumatic ankle-foot prosthesis is detailed that is able to replicate the biological ankle's torque and angle profiles during walking. The prosthetic ankle is comprised of a pneumatic piston, bending spring and solenoid valve. The mechanical properties of the pneumatic ankle prosthesis are characterized using a materials testing machine and the properties are compared to those from a common, passive ESR prosthetic foot. The characterization spanned a range of ankle equilibrium pressures and testing locations beneath the foot, analogous to the location of center of pressure within the stance phase of walking. The pneumatic ankle prosthesis was shown to provide biologically appropriate trends and magnitudes of torque, angle and stiffness behavior, when compared to the passive ESR prosthetic foot. Future work will focus on the development of a control system for the quasi-passive device and clinical testing of the pneumatic ankle to demonstrate efficacy.

  4. 40 CFR 86.1868-12 - CO2 credits for improving the efficiency of air conditioning systems.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... Creditvalue (g/mi) Reduced reheat, with externally-controlled, variable-displacement compressor (e.g. a compressor that controls displacement based on temperature setpoint and/or cooling demand of the air...-controlled, fixed-displacement or pneumatic variable displacement compressor (e.g. a compressor that controls...

  5. 49 CFR 232.602 - Applicability.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ..., DEPARTMENT OF TRANSPORTATION BRAKE SYSTEM SAFETY STANDARDS FOR FREIGHT AND OTHER NON-PASSENGER TRAINS AND EQUIPMENT; END-OF-TRAIN DEVICES Electronically Controlled Pneumatic (ECP) Braking Systems § 232.602... this part and equipped with an ECP brake system. Unless specifically excepted or modified in this...

  6. Experimental Verification of Pneumatic Transport System for the Rapid Excavation of Tunnels: Part 1. Installation of Test Facility

    DOT National Transportation Integrated Search

    1978-03-01

    This report deals with the selection of a test site, the design of a test installation, equipment selection, the installation and start-up of a pneumatic pipeline system for the transportation of tunnel muck. A review of prior pneumatic applications ...

  7. The MK VI - A second generation attitude control system

    NASA Astrophysics Data System (ADS)

    Meredith, P. J.

    1986-10-01

    The MK VI, a new multipurpose attitude control system for the exoatmospheric attitude control of sounding rocket payloads, is described. The system employs reprogrammable microcomputer memory for storage of basic control logic and for specific mission event control data. The paper includes descriptions of MK VI specifications and configuration; sensor characteristics; the electronic, analog, and digital sections; the pneumatic system; ground equipment; the system operation; and software. A review of the MK VI performance for the Comet Halley flight is presented. Block diagrams are included.

  8. Spool valve cycles at controlled frequency

    NASA Technical Reports Server (NTRS)

    Charlton, K. W.; Van Arnam, D. E.

    1966-01-01

    Spool valve accurately controls the cycle of a pneumatically-actuated system over long periods. Regulation of pressure from the external source, positioning of the adjusting plugs, and magnet selection, together afford wide variation in cyclic timing and speed of closure in either direction.

  9. Design of a pneumatically powered wearable exoskeleton with biomimetic support and actuation

    NASA Astrophysics Data System (ADS)

    Sergeyev, A.; Alaraje, N.; Seidel, C.; Carlson, Z.; Breda, B.

    Powered exoskeletons are designed to assist and protect the wearer. Depending on the situation they may be used to protect soldiers and construction workers, aid the survival of people in dangerous environments, or assist patients in rehabilitation. Regardless of the application there are strict requirements for designing and producing exoskeleton suites. They must be durable but light weight and flexible, have reliable power control and modulation, capable of detecting unsafe and invalid motions, and may require significant weight lifting capabilities. In this article we present an on-going research on robotic exoskeleton replicating of human muscle functions. A single wearable knee-joint prototype described in this article combines the use of soft pneumatic muscle-like actuators and a control system based off the users own natural muscle signals. The Pneumatic Exoskeleton uses bioelectrical signals to detect movement intention from the pilot. This paper details the technical design aspects of a lower-limb robotic exoskeleton with possibility of further expansion to fully functioning robotic exoskeleton suit.

  10. Pneumatic oscillator circuits for timing and control of integrated microfluidics.

    PubMed

    Duncan, Philip N; Nguyen, Transon V; Hui, Elliot E

    2013-11-05

    Frequency references are fundamental to most digital systems, providing the basis for process synchronization, timing of outputs, and waveform synthesis. Recently, there has been growing interest in digital logic systems that are constructed out of microfluidics rather than electronics, as a possible means toward fully integrated laboratory-on-a-chip systems that do not require any external control apparatus. However, the full realization of this goal has not been possible due to the lack of on-chip frequency references, thus requiring timing signals to be provided from off-chip. Although microfluidic oscillators have been demonstrated, there have been no reported efforts to characterize, model, or optimize timing accuracy, which is the fundamental metric of a clock. Here, we report pneumatic ring oscillator circuits built from microfluidic valves and channels. Further, we present a compressible-flow analysis that differs fundamentally from conventional circuit theory, and we show the utility of this physically based model for the optimization of oscillator stability. Finally, we leverage microfluidic clocks to demonstrate circuits for the generation of phase-shifted waveforms, self-driving peristaltic pumps, and frequency division. Thus, pneumatic oscillators can serve as on-chip frequency references for microfluidic digital logic circuits. On-chip clocks and pumps both constitute critical building blocks on the path toward achieving autonomous laboratory-on-a-chip devices.

  11. A Laser-Based Measuring System for Online Quality Control of Car Engine Block.

    PubMed

    Li, Xing-Qiang; Wang, Zhong; Fu, Lu-Hua

    2016-11-08

    For online quality control of car engine production, pneumatic measurement instrument plays an unshakeable role in measuring diameters inside engine block because of its portability and high-accuracy. To the limitation of its measuring principle, however, the working space between the pneumatic device and measured surface is too small to require manual operation. This lowers the measuring efficiency and becomes an obstacle to perform automatic measurement. In this article, a high-speed, automatic measuring system is proposed to take the place of pneumatic devices by using a laser-based measuring unit. The measuring unit is considered as a set of several measuring modules, where each of them acts like a single bore gauge and is made of four laser triangulation sensors (LTSs), which are installed on different positions and in opposite directions. The spatial relationship among these LTSs was calibrated before measurements. Sampling points from measured shaft holes can be collected by the measuring unit. A unified mathematical model was established for both calibration and measurement. Based on the established model, the relative pose between the measuring unit and measured workpiece does not impact the measuring accuracy. This frees the measuring unit from accurate positioning or adjustment, and makes it possible to realize fast and automatic measurement. The proposed system and method were finally validated by experiments.

  12. Detection of gas leakage

    DOEpatents

    Thornberg, Steven [Peralta, NM; Brown, Jason [Albuquerque, NM

    2012-06-19

    A method of detecting leaks and measuring volumes as well as an apparatus, the Power-free Pump Module (PPM), that is a self-contained leak test and volume measurement apparatus that requires no external sources of electrical power during leak testing or volume measurement, where the invention is a portable, pneumatically-controlled instrument capable of generating a vacuum, calibrating volumes, and performing quantitative leak tests on a closed test system or device, all without the use of alternating current (AC) power. Capabilities include the ability is to provide a modest vacuum (less than 10 Torr), perform a pressure rise leak test, measure the gas's absolute pressure, and perform volume measurements. All operations are performed through a simple rotary control valve which controls pneumatically-operated manifold valves.

  13. Detection of gas leakage

    DOEpatents

    Thornberg, Steven M; Brown, Jason

    2015-02-17

    A method of detecting leaks and measuring volumes as well as a device, the Power-free Pump Module (PPM), provides a self-contained leak test and volume measurement apparatus that requires no external sources of electrical power during leak testing or volume measurement. The PPM is a portable, pneumatically-controlled instrument capable of generating a vacuum, calibrating volumes, and performing quantitative leak tests on a closed test system or device, all without the use of alternating current (AC) power. Capabilities include the ability is to provide a modest vacuum (less than 10 Torr) using a venturi pump, perform a pressure rise leak test, measure the gas's absolute pressure, and perform volume measurements. All operations are performed through a simple rotary control valve which controls pneumatically-operated manifold valves.

  14. 49 CFR 232.605 - Training requirements.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ..., DEPARTMENT OF TRANSPORTATION BRAKE SYSTEM SAFETY STANDARDS FOR FREIGHT AND OTHER NON-PASSENGER TRAINS AND EQUIPMENT; END-OF-TRAIN DEVICES Electronically Controlled Pneumatic (ECP) Braking Systems § 232.605 Training... equipped with an ECP brake system and each contractor that performs inspection, testing, or maintenance on...

  15. Analytical Solution to the Pneumatic Transient Rod System at ACRR

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fehr, Brandon Michael

    2016-01-08

    The ACRR pulse is pneumatically driven by nitrogen in a system of pipes, valves and hoses up to the connection of the pneumatic system and mechanical linkages of the transient rod (TR). The main components of the TR pneumatic system are the regulator, accumulator, solenoid valve and piston-cylinder assembly. The purpose of this analysis is to analyze the flow of nitrogen through the TR pneumatic system in order to develop a motion profile of the piston during the pulse and be able to predict the pressure distributions inside both the cylinder and accumulators. The predicted pressure distributions will be validatedmore » against pressure transducer data, while the motion profile will be compared to proximity switch data. By predicting the motion of the piston, pulse timing will be determined and provided to the engineers/operators for verification. The motion profile will provide an acceleration distribution to be used in Razorback to more accurately predict reactivity insertion into the system.« less

  16. Adding the ‘heart’ to hanging drop networks for microphysiological multi-tissue experiments†

    PubMed Central

    Yazdi, Saeed Rismani; Shadmani, Amir; Bürgel, Sebastian C.; Misun, Patrick M.; Hierlemann, Andreas; Frey, Olivier

    2017-01-01

    Microfluidic hanging-drop networks enable culturing and analysis of 3D microtissue spheroids derived from different cell types under controlled perfusion and investigating inter-tissue communication in multi-tissue formats. In this paper we introduce a compact on-chip pumping approach for flow control in hanging-drop networks. The pump includes one pneumatic chamber located directly above one of the hanging drops and uses the surface tension at the liquid–air-interface for flow actuation. Control of the pneumatic protocol provides a wide range of unidirectional pulsatile and continuous flow profiles. With the proposed concept several independent hanging-drop networks can be operated in parallel with only one single pneumatic actuation line at high fidelity. Closed-loop medium circulation between different organ models for multi-tissue formats and multiple simultaneous assays in parallel are possible. Finally, we implemented a real-time feedback control-loop of the pump actuation based on the beating of a human iPS-derived cardiac microtissue cultured in the same system. This configuration allows for simulating physiological effects on the heart and their impact on flow circulation between the organ models on chip. PMID:26401602

  17. Pneumatic-type surgical robot end-effector for laparoscopic surgical-operation-by-wire.

    PubMed

    Lee, Chiwon; Park, Woo Jung; Kim, Myungjoon; Noh, Seungwoo; Yoon, Chiyul; Lee, Choonghee; Kim, Youdan; Kim, Hyeon Hoe; Kim, Hee Chan; Kim, Sungwan

    2014-09-05

    Although minimally invasive surgery (MIS) affords several advantages compared to conventional open surgery, robotic MIS systems still have many limitations. One of the limitations is the non-uniform gripping force due to mechanical strings of the existing systems. To overcome this limitation, a surgical instrument with a pneumatic gripping system consisting of a compressor, catheter balloon, micro motor, and other parts is developed. This study aims to implement a surgical instrument with a pneumatic gripping system and pitching/yawing joints using micro motors and without mechanical strings based on the surgical-operation-by-wire (SOBW) concept. A 6-axis external arm for increasing degrees of freedom (DOFs) is integrated with the surgical instrument using LabVIEW® for laparoscopic procedures. The gripping force is measured over a wide range of pressures and compared with the simulated ideal step function. Furthermore, a kinematic analysis is conducted. To validate and evaluate the system's clinical applicability, a simple peg task experiment and workspace identification experiment are performed with five novice volunteers using the fundamentals of laparoscopic surgery (FLS) board kit. The master interface of the proposed system employs the hands-on-throttle-and-stick (HOTAS) controller used in aerospace engineering. To develop an improved HOTAS (iHOTAS) controller, 6-axis force/torque sensor was integrated in the special housing. The mean gripping force (after 1,000 repetitions) at a pressure of 0.3 MPa was measured to be 5.8 N. The reaction time was found to be 0.4 s, which is almost real-time. All novice volunteers could complete the simple peg task within a mean time of 176 s, and none of them exceeded the 300 s cut-off time. The system's workspace was calculated to be 11,157.0 cm3. The proposed pneumatic gripping system provides a force consistent with that of other robotic MIS systems. It provides near real-time control. It is more durable than the existing other surgical robot systems. Its workspace is sufficient for clinical surgery. Therefore, the proposed system is expected to be widely used for laparoscopic robotic surgery. This research using iHOTAS will be applied to the tactile force feedback system for surgeon's safe operation.

  18. 49 CFR 661.11 - Rolling stock procurements.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... Devices; (21) Car Axle Counters; (22) Communication Based Train Control (CBTC). (u) Communication... components of a bus. This list is not all-inclusive. Car body shells, egines, transmissions, front axle... assemblies, air compressor and pneumatic systems, generator/alternator and electrical systems, steering...

  19. 49 CFR 661.11 - Rolling stock procurements.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... Devices; (21) Car Axle Counters; (22) Communication Based Train Control (CBTC). (u) Communication... components of a bus. This list is not all-inclusive. Car body shells, egines, transmissions, front axle... assemblies, air compressor and pneumatic systems, generator/alternator and electrical systems, steering...

  20. Investigation of ecological parameters of four-stroke SI engine, with pneumatic fuel injection system

    NASA Astrophysics Data System (ADS)

    Marek, W.; Śliwiński, K.

    2016-09-01

    The publication presents the results of tests to determine the impact of using waste fuels, alcohol, to power the engine, on the ecological parameters of the combustion engine. Alternatively fuelled with a mixture of iso- and n-butanol, indicated with "X" and "END, and gasoline and a mixture of fuel and alcohol. The object of the study was a four-stroke engine with spark ignition designed to work with a generator. Motor power was held by the modified system of pneumatic injection using hot exhaust gases developed by Prof. Stanislaw Jarnuszkiewicz, controlled by modern mechatronic systems. Tests were conducted at a constant speed for the intended use of the engine. The subject of the research was to determine the control parameters such as ignition timing, mixture composition and the degree of exhaust gas recirculation on the ecological parameters of the engine. Tests were carried out using partially quality power control. In summary we present the findings of this phase of the study.

  1. 46 CFR 56.97-35 - Pneumatic tests (replaces 137.5).

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 2 2012-10-01 2012-10-01 false Pneumatic tests (replaces 137.5). 56.97-35 Section 56.97-35 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING PIPING SYSTEMS AND APPURTENANCES Pressure Tests § 56.97-35 Pneumatic tests (replaces 137.5). (a) General Requirements. When a pneumatic test is performed, it...

  2. Coal-fluid properties with an emphasis on dense phase. Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Klinzing, G.E.

    1985-04-01

    Many fossil fuel energy processes depend on the movement of solids by pneumatic transport. Despite the considerable amount of work reported in the literature on pneumatic transport, the design of new industrial systems for new products continues to rely to a great extent on empiricism. A pilot-scale test facility has been constructed at Pittsburgh Energy Technology Center (PETC), equipped with modern sophisticated measuring techniques (such as Pressure Transducers, Auburn Monitors and Micro Motion Mass Flow Meters) and an automatic computer-controlled data acquisition system to study the effects of particle pneumatic transport. Pittsburgh Seam and Montana Rosebud coals of varying sizemore » consist and moisture content were tested in the atmospheric and pressurized coal flow test loops (AP/CFTL and HP/CFTL) at PETC. The system parameters included conveying gas velocity, injector tank pressure, screw conveyor speed, pipe radius and pipe bends. In this report, results from the coal flow tests were presented and analyzed. Existing theories and correlations on two phase flows were reviewed. Experimental data were compared with values calculated from empirically or theoretically derived equations available in the literature and new correlations were proposed, when applicable, to give a better interpretation of the data and a better understanding of the various flow regimes involved in pneumatic transport. 55 refs., 56 figs., 6 tabs.« less

  3. Design and analysis of an active optics system for a 4-m telescope mirror combining hydraulic and pneumatic supports

    NASA Astrophysics Data System (ADS)

    Lousberg, Gregory P.; Moreau, Vincent; Schumacher, Jean-Marc; Piérard, Maxime; Somja, Aude; Gloesener, Pierre; Flebus, Carlo

    2015-09-01

    AMOS has developed a hybrid active optics system that combines hydraulic and pneumatic properties of actuators to support a 4-m primary mirror. The mirror is intended to be used in the Daniel K. Inouye Solar Telescope (DKIST, formerly the Advanced Technology Solar Telescope) that will be installed by the National Solar Observatory (NSO) atop the Haleakala volcano in Hawaii. The mirror support design is driven by the needs of (1) minimizing the support-induced mirror distortions under telescope operating conditions, (2) shaping the mirror surface to the desired profile, and (3) providing a high stiffness against wind loads. In order to fulfill these requirements, AMOS proposes an innovative support design that consist of 118 axial actuators and 24 lateral actuators. The axial support is based on coupled hydraulic and pneumatic actuators. The hydraulic part is a passive system whose main function is to support the mirror weight with a high stiffness. The pneumatic part is actively controlled so as to compensate for low-order wavefront aberrations that are generated by the mirror support itself or by any other elements in the telescope optical chain. The performances of the support and its adequacy with the requirements are assessed with the help of a comprehensive analysis loop involving finite-element, thermal and optical modellings.

  4. NHTSA's heavy duty vehicle brake research program report number 11 : evaluation of stopping performance of trailer antilock brake systems

    DOT National Transportation Integrated Search

    1997-04-01

    In order to better understand the functioning of antilock brake systems on pneumatically braked trailers, a series of tests were conducted to evaluate different ABS control strategies, performance variations among systems supplied by different manufa...

  5. 60. Shock isolator at center, pneumatic control group panel at ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    60. Shock isolator at center, pneumatic control group panel at left, power distribution box at right, all at right of entrance to lcc. - Ellsworth Air Force Base, Delta Flight, Launch Control Facility, County Road CS23A, North of Exit 127, Interior, Jackson County, SD

  6. Dynamic Friction Performance of a Pneumatic Cylinder with Al2O3 Film on Cylinder Surface.

    PubMed

    Chang, Ho; Lan, Chou-Wei; Wang, Hao-Xian

    2015-11-01

    A friction force system is proposed for accurately measuring friction force and motion properties produced by reciprocating motion of piston in a pneumatic cylinder. In this study, the proposed system is used to measure the effects of lubricating greases of different viscosities on the friction properties of pneumatic cylinder, and improvement of stick-slip motion for the cylinder bore by anodizing processes. A servo motor-driven ball screw is used to drive the pneumatic cylinder to be tested and to measure the change in friction force of the pneumatic cylinder. Experimental results show, that under similar test conditions, the lubricating grease with viscosity VG100 is best suited for measuring reciprocating motion of the piston of pneumatic cylinder. The wear experiment showed that, in the Al2O3 film obtained at a preset voltage 40 V in the anodic process, the friction coefficient and hardness decreased by 55% and increased by 274% respectively, thus achieving a good tribology and wear resistance. Additionally, the amplitude variation in the friction force of the pneumatic cylinder wall that received the anodizing treatment was substantially reduced. Additionally, the stick-slip motion of the pneumatic cylinder during low-speed motion was substantially improved.

  7. Design type air engine Di Pietro

    NASA Astrophysics Data System (ADS)

    Zwierzchowski, Jaroslaw

    The article presents a pneumatic engine constructed by Angelo Di Pietro. 3D solid models of pneumatic engine components were presented therein. A directional valve is a key element of the control system. The valve functions as a camshaft distributing air to particular engine chambers. The construction designed by Angelo Di Pietro is modern and innovative. A pneumatic engine requires low pressure to start rotary movement. With the use of CFD software, the fields of velocity vectors' distribution were determined. Moreover, the author determined the distribution of pressure values in engine inlet and outlet channels. CFD model studies on engine operation were conducted for chosen stages of operating cycles. On the basis of simulation tests that were conducted, the values of flow rates for the engine were determined. The distribution of pressure values made it possible to evaluate the torque value on the rotating shaft.

  8. Practical controller design for ultra-precision positioning of stages with a pneumatic artificial muscle actuator

    NASA Astrophysics Data System (ADS)

    Tang, T. F.; Chong, S. H.

    2017-06-01

    This paper presents a practical controller design method for ultra-precision positioning of pneumatic artificial muscle actuator stages. Pneumatic artificial muscle (PAM) actuators are safe to use and have numerous advantages which have brought these actuators to wide applications. However, PAM exhibits strong non-linear characteristics, and these limitations lead to low controllability and limit its application. In practice, the non-linear characteristics of PAM mechanism are difficult to be precisely modeled, and time consuming to model them accurately. The purpose of the present study is to clarify a practical controller design method that emphasizes a simple design procedure that does not acquire plants parameters modeling, and yet is able to demonstrate ultra-precision positioning performance for a PAM driven stage. The practical control approach adopts continuous motion nominal characteristic trajectory following (CM NCTF) control as the feedback controller. The constructed PAM driven stage is in low damping characteristic and causes severe residual vibration that deteriorates motion accuracy of the system. Therefore, the idea to increase the damping characteristic by having an acceleration feedback compensation to the plant has been proposed. The effectiveness of the proposed controller was verified experimentally and compared with a classical PI controller in point-to-point motion. The experiment results proved that the CM NCTF controller demonstrates better positioning performance in smaller motion error than the PI controller. Overall, the CM NCTF controller has successfully to reduce motion error to 3µm, which is 88.7% smaller than the PI controller.

  9. Integration of Pneumatic Technology in Powered Mobility Devices

    PubMed Central

    Daveler, Brandon; Wang, Hongwu; Gebrosky, Benjamin; Grindle, Garrett G.; Schneider, Urs

    2017-01-01

    Advances in electric motors, electronics, and control systems have enhanced the capability and drivability of electric power mobility devices over the last 60 years. Yet, battery technologies used in powered mobility devices (PMDs) have not kept pace. Recent advances in pneumatic technology, primarily the high torque, low speed design of rotary piston air motors, directly align with the needs of PMD. Pneumatic technology has advantages over battery-powered technology, including lighter weight, lower operating costs, decreased environmental impact, better reliability, and increased safety. Two prototypes were created that incorporated rotary piston air motors, high-pressure air tanks, and air-pressure regulators. Prototype 1 was created by modifying an existing electric PMD. Range tests were performed to determine the feasibility of pneumatic technology and the optimal combination of components to allow the longest range possible at acceptable speeds over ideal conditions. Using a 1.44 L air tank for feasibility testing, prototype 1 was capable of traveling 800 m, which confirmed the feasibility of pneumatic technology usage in PMDs. Prototype 2 was designed based on the testing results from prototype 1. After further optimization of prototype 2, the average maximum range was 3,150 m. Prototype 2 is up to 28.3% lighter than an equivalent size electric PMD and can be fully recharged in approximately 2 minutes. It decreases the cost of PMDs by approximately $1,500, because batteries do not need to be replaced over the lifetime of the device. The results provide justification for the use of pneumatic technology in PMDs. PMID:29339888

  10. Integration of Pneumatic Technology in Powered Mobility Devices.

    PubMed

    Daveler, Brandon; Wang, Hongwu; Gebrosky, Benjamin; Grindle, Garrett G; Schneider, Urs; Cooper, Rory A

    2017-01-01

    Advances in electric motors, electronics, and control systems have enhanced the capability and drivability of electric power mobility devices over the last 60 years. Yet, battery technologies used in powered mobility devices (PMDs) have not kept pace. Recent advances in pneumatic technology, primarily the high torque, low speed design of rotary piston air motors, directly align with the needs of PMD. Pneumatic technology has advantages over battery-powered technology, including lighter weight, lower operating costs, decreased environmental impact, better reliability, and increased safety. Two prototypes were created that incorporated rotary piston air motors, high-pressure air tanks, and air-pressure regulators. Prototype 1 was created by modifying an existing electric PMD. Range tests were performed to determine the feasibility of pneumatic technology and the optimal combination of components to allow the longest range possible at acceptable speeds over ideal conditions. Using a 1.44 L air tank for feasibility testing, prototype 1 was capable of traveling 800 m, which confirmed the feasibility of pneumatic technology usage in PMDs. Prototype 2 was designed based on the testing results from prototype 1. After further optimization of prototype 2, the average maximum range was 3,150 m. Prototype 2 is up to 28.3% lighter than an equivalent size electric PMD and can be fully recharged in approximately 2 minutes. It decreases the cost of PMDs by approximately $1,500, because batteries do not need to be replaced over the lifetime of the device. The results provide justification for the use of pneumatic technology in PMDs.

  11. 49 CFR 232.613 - End-of-train devices.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ..., DEPARTMENT OF TRANSPORTATION BRAKE SYSTEM SAFETY STANDARDS FOR FREIGHT AND OTHER NON-PASSENGER TRAINS AND EQUIPMENT; END-OF-TRAIN DEVICES Electronically Controlled Pneumatic (ECP) Braking Systems § 232.613 End-of... equipped with an ECP brake system unless that train is equipped with a functioning ECP-EOT device designed...

  12. Three-dimensional construction and omni-directional rolling analysis of a novel frame-like lattice modular robot

    NASA Astrophysics Data System (ADS)

    Ding, Wan; Wu, Jianxu; Yao, Yan'an

    2015-07-01

    Lattice modular robots possess diversity actuation methods, such as electric telescopic rod, gear rack, magnet, robot arm, etc. The researches on lattice modular robots mainly focus on their hardware descriptions and reconfiguration algorithms. Meanwhile, their design architectures and actuation methods perform slow telescopic and moving speeds, relative low actuation force verse weight ratio, and without internal space to carry objects. To improve the mechanical performance and reveal the locomotion and reconfiguration binary essences of the lattice modular robots, a novel cube-shaped, frame-like, pneumatic-based reconfigurable robot module called pneumatic expandable cube(PE-Cube) is proposed. The three-dimensional(3D) expanding construction and omni-directional rolling analysis of the constructed robots are the main focuses. The PE-Cube with three degrees of freedom(DoFs) is assembled by replacing the twelve edges of a cube with pneumatic cylinders. The proposed symmetric construction condition makes the constructed robots possess the same properties in each supporting state, and a binary control strategy cooperated with binary actuator(pneumatic cylinder) is directly adopted to control the PE-Cube. Taking an eight PE-Cube modules' construction as example, its dynamic rolling simulation, static rolling condition, and turning gait are illustrated and discussed. To testify telescopic synchronization, respond speed, locomotion feasibility, and repeatability and reliability of hardware system, an experimental pneumatic-based robotic system is built and the rolling and turning experiments of the eight PE-Cube modules' construction are carried out. As an extension, the locomotion feasibility of a thirty-two PE-Cube modules' construction is analyzed and proved, including dynamic rolling simulation, static rolling condition, and dynamic analysis in free tipping process. The proposed PE-Cube module, construction method, and locomotion analysis enrich the family of the lattice modular robot and provide the instruction to design the lattice modular robot.

  13. 49 CFR 232.605 - Training requirements.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 4 2011-10-01 2011-10-01 false Training requirements. 232.605 Section 232.605..., DEPARTMENT OF TRANSPORTATION BRAKE SYSTEM SAFETY STANDARDS FOR FREIGHT AND OTHER NON-PASSENGER TRAINS AND EQUIPMENT; END-OF-TRAIN DEVICES Electronically Controlled Pneumatic (ECP) Braking Systems § 232.605 Training...

  14. Active pneumatic vibration isolation system using negative stiffness structures for a vehicle seat

    NASA Astrophysics Data System (ADS)

    Danh, Le Thanh; Ahn, Kyoung Kwan

    2014-02-01

    In this paper, an active pneumatic vibration isolation system using negative stiffness structures (NSS) for a vehicle seat in low excitation frequencies is proposed, which is named as an active system with NSS. Here, the negative stiffness structures (NSS) are used to minimize the vibratory attraction of a vehicle seat. Owing to the time-varying and nonlinear behavior of the proposed system, it is not easy to build an accurate dynamic for model-based controller design. Thus, an adaptive intelligent backstepping controller (AIBC) is designed to manage the system operation for high-isolation effectiveness. In addition, an auxiliary control effort is also introduced to eliminate the effect of the unpredictable perturbations. Moreover, a radial basis function neural network (RBFNN) model is utilized to estimate the optimal gain of the auxiliary control effort. Final control input and the adaptive law for updating coefficients of the approximate series can be obtained step by step using a suitable Lyapunov function. Afterward, the isolation performance of the proposed system is assessed experimentally. In addition, the effectiveness of the designed controller for the proposed system is also compared with that of the traditional backstepping controller (BC). The experimental results show that the isolation effectiveness of the proposed system is better than that of the active system without NSS. Furthermore, the undesirable chattering phenomenon in control effort is quite reduced by the estimation mechanism. Finally, some concluding remarks are given at the end of the paper.

  15. Photographic Equipment Test System (PETS)

    NASA Technical Reports Server (NTRS)

    1975-01-01

    The Photographic Equipment Test System is presented. The device is a mobile optical system designed for evaluating performance of various sensors in a laboratory, in a vacuum chamber or on a flight line. The carriage is designed to allow elevation as well as azimuth control of the direction of the light from the collimator. The pneumatic tires provide an effective vibration isolation system. A target/illumination system is mounted on a motor driven linear slide, and focusing and exposure control can be operated remotely from the small electronics control console.

  16. Personal digital assistant-based, internet-enabled remote communication system for a wearable pneumatic biventricular assist device.

    PubMed

    Nam, Kyoung Won; Lee, Jung Joo; Hwang, Chang Mo; Choi, Seong Wook; Son, Ho Sung; Sun, Kyung

    2007-11-01

    Currently, personal mobile communication devices have become quite common, and the applications of such devices have expanded quickly. Remote communication systems might be employed for the telemonitoring of patients or the operating status of their medical devices. In this article, we describe the development of a mobile-based artificial heart telemanagement system for use in a wearable extracorporeal pneumatic biventricular assist device, which is capable of telemonitoring and telecontrolling the operating status of the ventricular assist device from any site. The system developed herein utilized small mobile phones for the client device and adopted a standard transmission control protocol/Internet protocol communication protocol for the purposes of telecommunication. The results of in vitro and animal experiments showed that the telemanagement system developed herein operated in accordance with the desired parameters.

  17. Disturbance-Estimated Adaptive Backstepping Sliding Mode Control of a Pneumatic Muscles-Driven Ankle Rehabilitation Robot

    PubMed Central

    Ai, Qingsong; Zhu, Chengxiang; Zuo, Jie; Liu, Quan; Xie, Sheng Q.; Yang, Ming

    2017-01-01

    A rehabilitation robot plays an important role in relieving the therapists’ burden and helping patients with ankle injuries to perform more accurate and effective rehabilitation training. However, a majority of current ankle rehabilitation robots are rigid and have drawbacks in terms of complex structure, poor flexibility and lack of safety. Taking advantages of pneumatic muscles’ good flexibility and light weight, we developed a novel two degrees of freedom (2-DOF) parallel compliant ankle rehabilitation robot actuated by pneumatic muscles (PMs). To solve the PM’s nonlinear characteristics during operation and to tackle the human-robot uncertainties in rehabilitation, an adaptive backstepping sliding mode control (ABS-SMC) method is proposed in this paper. The human-robot external disturbance can be estimated by an observer, who is then used to adjust the robot output to accommodate external changes. The system stability is guaranteed by the Lyapunov stability theorem. Experimental results on the compliant ankle rehabilitation robot show that the proposed ABS-SMC is able to estimate the external disturbance online and adjust the control output in real time during operation, resulting in a higher trajectory tracking accuracy and better response performance especially in dynamic conditions. PMID:29283406

  18. Disturbance-Estimated Adaptive Backstepping Sliding Mode Control of a Pneumatic Muscles-Driven Ankle Rehabilitation Robot.

    PubMed

    Ai, Qingsong; Zhu, Chengxiang; Zuo, Jie; Meng, Wei; Liu, Quan; Xie, Sheng Q; Yang, Ming

    2017-12-28

    A rehabilitation robot plays an important role in relieving the therapists' burden and helping patients with ankle injuries to perform more accurate and effective rehabilitation training. However, a majority of current ankle rehabilitation robots are rigid and have drawbacks in terms of complex structure, poor flexibility and lack of safety. Taking advantages of pneumatic muscles' good flexibility and light weight, we developed a novel two degrees of freedom (2-DOF) parallel compliant ankle rehabilitation robot actuated by pneumatic muscles (PMs). To solve the PM's nonlinear characteristics during operation and to tackle the human-robot uncertainties in rehabilitation, an adaptive backstepping sliding mode control (ABS-SMC) method is proposed in this paper. The human-robot external disturbance can be estimated by an observer, who is then used to adjust the robot output to accommodate external changes. The system stability is guaranteed by the Lyapunov stability theorem. Experimental results on the compliant ankle rehabilitation robot show that the proposed ABS-SMC is able to estimate the external disturbance online and adjust the control output in real time during operation, resulting in a higher trajectory tracking accuracy and better response performance especially in dynamic conditions.

  19. Successful MPPF Pneumatics Verification and Validation Testing

    NASA Image and Video Library

    2017-03-28

    Engineers and technicians completed verification and validation testing of several pneumatic systems inside and outside the Multi-Payload Processing Facility (MPPF) at NASA's Kennedy Space Center in Florida. In view is the service platform for Orion spacecraft processing. To the left are several pneumatic panels. The MPPF will be used for offline processing and fueling of the Orion spacecraft and service module stack before launch. Orion also will be de-serviced in the MPPF after a mission. The Ground Systems Development and Operations Program (GSDO) is overseeing upgrades to the facility. The Engineering Directorate led the recent pneumatic tests.

  20. A Laser-Based Measuring System for Online Quality Control of Car Engine Block

    PubMed Central

    Li, Xing-Qiang; Wang, Zhong; Fu, Lu-Hua

    2016-01-01

    For online quality control of car engine production, pneumatic measurement instrument plays an unshakeable role in measuring diameters inside engine block because of its portability and high-accuracy. To the limitation of its measuring principle, however, the working space between the pneumatic device and measured surface is too small to require manual operation. This lowers the measuring efficiency and becomes an obstacle to perform automatic measurement. In this article, a high-speed, automatic measuring system is proposed to take the place of pneumatic devices by using a laser-based measuring unit. The measuring unit is considered as a set of several measuring modules, where each of them acts like a single bore gauge and is made of four laser triangulation sensors (LTSs), which are installed on different positions and in opposite directions. The spatial relationship among these LTSs was calibrated before measurements. Sampling points from measured shaft holes can be collected by the measuring unit. A unified mathematical model was established for both calibration and measurement. Based on the established model, the relative pose between the measuring unit and measured workpiece does not impact the measuring accuracy. This frees the measuring unit from accurate positioning or adjustment, and makes it possible to realize fast and automatic measurement. The proposed system and method were finally validated by experiments. PMID:27834839

  1. System for Dispensing a Precise Amount of Fluid

    DOEpatents

    Benett, William J.; Krulevitch, Peter A.; Visuri, Steven R.; Dzenitis, John M.; Ness, Kevin D.

    2008-08-12

    A dispensing system delivers a precise amount of fluid for biological or chemical processing and/or analysis. Dispensing means moves the fluid. The dispensing means is operated by a pneumatic force. Connection means delivers the fluid to the desired location. An actuator means provides the pneumatic force to the dispensing means. Valving means transmits the pneumatic force from the actuator means to the dispensing means.

  2. A comparison of intermittent pneumatic compression of the calf and whole leg in preventing deep venous thrombosis in urological surgery.

    PubMed

    Soderdahl, D W; Henderson, S R; Hansberry, K L

    1997-05-01

    Intermittent pneumatic compression of the calf and/or thigh effectively decreases the incidence of deep venous thrombosis and other thrombotic sequelae but clinical data comparing these modalities are currently lacking. A total of 90 patients undergoing major urological surgery was randomly assigned to receive calf length or thigh length pneumatic compression for antithrombotic prophylaxis. Duplex ultrasound of the lower extremities was performed preoperatively and twice postoperatively to evaluate for deep venous thrombosis. Health care providers in the operating room, recovery room and ward were asked to compare the compression systems, and a cost analysis was performed. A total of 47 patients wore the thigh length sequential pneumatic sleeves and 43 wore calf length uniform compression systems. A pulmonary embolus without evidence of deep venous thrombosis was detected in 1 patient (2%) using the thigh length system. A thrombus was detected in the common femoral vein by duplex ultrasonography in 1 patient (2%) with the calf length system. Nursing personnel found the calf length sleeves easier to apply and more comfortable by patient account but they were satisfied with both systems. There was a significant cost savings with the calf length pneumatic compression system. Calf and thigh length pneumatic compression systems similarly decrease the risk of deep venous thrombosis in patients undergoing urological surgery. The calf length system has the added advantage of being less expensive and easier to use.

  3. Thrust control system design of ducted rockets

    NASA Astrophysics Data System (ADS)

    Chang, Juntao; Li, Bin; Bao, Wen; Niu, Wenyu; Yu, Daren

    2011-07-01

    The investigation of the thrust control system is aroused by the need for propulsion system of ducted rockets. Firstly the dynamic mathematical models of gas flow regulating system, pneumatic servo system and ducted rocket engine were established and analyzed. Then, to conquer the discussed problems of thrust control, the idea of information fusion was proposed to construct a new feedback variable. With this fused feedback variable, the thrust control system was designed. According to the simulation results, the introduction of the new fused feedback variable is valid in eliminating the contradiction between rapid response and stability for the thrust control system of ducted rockets.

  4. Development of circulation control technology for powered-lift STOL aircraft

    NASA Technical Reports Server (NTRS)

    Englar, Robert J.

    1987-01-01

    The flow entraining capabilities of the Circulation Control Wing high lift system were employed to provide an even stronger STOL potential when synergistically combined with upper surface mounted engines. The resulting configurations generate very high supercirculation lift in addition to a vertical component of the pneumatically deflected engine thrust. A series of small scale wind tunnel tests and full scale static thrust deflection tests are discussed which provide a sufficient data base performance. These tests results show thrust deflections of greater than 90 deg produced pneumatically by nonmoving aerodynamic surfaces, and the ability to maintain constant high lift while varying the propulsive force from high thrust recovery required for short takeoff to high drag generation required for short low speed landings.

  5. Improvement of Wearable Power Assist Wear for Low Back Support using Pneumatic Actuator

    NASA Astrophysics Data System (ADS)

    Cho, Feifei; Sugimoto, Riku; Noritsugu, Toshiro; Li, Xiangpan

    2017-10-01

    This study focuses on developing a safe, lightweight, power assist device that can be worn by people who like caregivers during lifting or static holding tasks to prevent low back pain (LBP). Therefore in consideration of their flexibility, light weight, and large force to weight ratio we have developed a Wearable Power Assist Wear for caregivers, two types of pneumatic actuators are employed in assisting low back movement for their safety and comfort. The device can be worn directly on the body like normal clothing. Because there is no rigid exoskeleton frame structure, it is lightweight and user friendly. In this paper, we proposed the new type of the wearable power assist wear and improved the controller of control system.

  6. Characterization of a pneumatic balloon actuator for use in refreshable Braille displays.

    PubMed

    Fan, Richard E; Feinman, Adam M; Wottawa, Christopher; King, Chih-Hung; Franco, Miguel L; Dutson, Erik P; Grundfest, Warren S; Culjat, Martin O

    2009-01-01

    Many existing refreshable Braille display technologies are costly or lack robust performance. A process has been developed to fabricate consistent and reliable pneumatic balloon actuators at low material cost, using a novel manufacturing process. This technique has been adapted for use in refreshable Braille displays that feature low power consumption, ease of manufacture and small form factor. A prototype refreshable cell, conforming to American Braille standards, was developed and tested. The cell was fabricated from molded PDMS to form balloon actuators with a spin-coated silicone film, and fast pneumatic driving elements and an electronic control system were developed to drive the Braille dots. Perceptual testing was performed to determine the feasibility of the approach using a single blind human subject. The subject was able to detect randomized Braille letters rapidly generated by the actuator with 100% character detection accuracy.

  7. Improving Legacy Aircraft Systems Through Condition-Based Maintenance: An H-60 Case Study

    DTIC Science & Technology

    2014-09-01

    level functions. These decompositions are equivalent to a detailed design effort in systems engineering. NAMPSOPs have a common architectural structure...Assembly Power Available Spindle Cables No.1 Engine Load Demand Spindle Control Cables Engine Pneumatic Starters Auxiliary Power Unit IRCM FLIR Mission...Analysis Fuel System Main Rotor Head Main Module Main Gear Box Radiator Engine Output Shaft Auxiliary Power Unit Flight Control Cables Tail Landing

  8. Waste Water Treatment Apparatus and Methods

    NASA Technical Reports Server (NTRS)

    Plawsky, Joel L. (Inventor); Paccione, John D. (Inventor); Littman, Howard (Inventor)

    2014-01-01

    An improved draft tube spout fluid bed (DTSFB) mixing, handling, conveying, and treating apparatus and systems, and methods for operating are provided. The apparatus and systems can accept particulate material and pneumatically or hydraulically conveying the material to mix and/or treat the material. In addition to conveying apparatus, a collection and separation apparatus adapted to receive the conveyed particulate material is also provided. The collection apparatus may include an impaction plate against which the conveyed material is directed to improve mixing and/or treatment. The improved apparatus are characterized by means of controlling the operation of the pneumatic or hydraulic transfer to enhance the mixing and/or reacting by controlling the flow of fluids, for example, air, into and out of the apparatus. The disclosed apparatus may be used to mix particulate material, for example, mortar; react fluids with particulate material; coat particulate material, or simply convey particulate material.

  9. Methods and apparatus for handling or treating particulate material

    NASA Technical Reports Server (NTRS)

    Littman, Howard (Inventor); Plawsky, Joel L. (Inventor); Paccione, John D. (Inventor)

    2009-01-01

    An improved draft tube spout fluid bed (DTSFB) mixing, handling, conveying, and treating apparatus and systems, and methods for operating are provided. The apparatus and systems can accept particulate material and pneumatically or hydraulically conveying the material to mix and/or treat the material. In addition to conveying apparatus, a collection and separation apparatus adapted to receive the conveyed particulate material is also provided. The collection apparatus may include an impaction plate against which the conveyed material is directed to improve mixing and/or treatment. The improved apparatus are characterized by means of controlling the operation of the pneumatic or hydraulic transfer to enhance the mixing and/or reacting by controlling the flow of fluids, for example, air, into and out of the apparatus. The disclosed apparatus may be used to mix particulate material, for example, mortar; react fluids with particulate material; coat particulate material, or simply convey particulate material.

  10. Powered Upper Limb Orthosis Actuation System Based on Pneumatic Artificial Muscles

    NASA Astrophysics Data System (ADS)

    Chakarov, Dimitar; Veneva, Ivanka; Tsveov, Mihail; Venev, Pavel

    2018-03-01

    The actuation system of a powered upper limb orthosis is studied in the work. To create natural safety in the mutual "man-robot" interaction, an actuation system based on pneumatic artificial muscles (PAM) is selected. Experimentally obtained force/contraction diagrams for bundles, consisting of different number of muscles are shown in the paper. The pooling force and the stiffness of the pneumatic actuators is assessed as a function of the number of muscles in the bundle and the supply pressure. Joint motion and torque is achieved by antagonistic actions through pulleys, driven by bundles of pneumatic muscles. Joint stiffness and joint torques are determined on condition of a power balance, as a function of the joint position, pressure, number of muscles and muscles

  11. Pneumatic soil removal tool

    DOEpatents

    Neuhaus, J.E.

    1992-10-13

    A soil removal tool is provided for removing radioactive soil, rock and other debris from the bottom of an excavation, while permitting the operator to be located outside of a containment for that excavation. The tool includes a fixed jaw, secured to one end of an elongate pipe, which cooperates with a movable jaw pivotably mounted on the pipe. Movement of the movable jaw is controlled by a pneumatic cylinder mounted on the pipe. The actuator rod of the pneumatic cylinder is connected to a collar which is slidably mounted on the pipe and forms part of the pivotable mounting assembly for the movable jaw. Air is supplied to the pneumatic cylinder through a handle connected to the pipe, under the control of an actuator valve mounted on the handle, to provide movement of the movable jaw. 3 figs.

  12. Pneumatic soil removal tool

    DOEpatents

    Neuhaus, John E.

    1992-01-01

    A soil removal tool is provided for removing radioactive soil, rock and other debris from the bottom of an excavation, while permitting the operator to be located outside of a containment for that excavation. The tool includes a fixed jaw, secured to one end of an elongate pipe, which cooperates with a movable jaw pivotably mounted on the pipe. Movement of the movable jaw is controlled by a pneumatic cylinder mounted on the pipe. The actuator rod of the pneumatic cylinder is connected to a collar which is slidably mounted on the pipe and forms part of the pivotable mounting assembly for the movable jaw. Air is supplied to the pneumatic cylinder through a handle connected to the pipe, under the control of an actuator valve mounted on the handle, to provide movement of the movable jaw.

  13. A randomized trial of pneumatic reduction versus hydrostatic reduction for intussusception in pediatric patients.

    PubMed

    Xie, Xiaolong; Wu, Yang; Wang, Qi; Zhao, Yiyang; Chen, Guobin; Xiang, Bo

    2017-08-08

    Data of randomly controlled trials comparing the hydrostatic and pneumatic reduction for intussusception in pediatric patients as initial therapy are lacking. The aim of this study was to conduct a randomly controlled trial to compare the effectiveness and safety of the hydrostatic and pneumatic reduction techniques. All intussusception patients who visited West China Hospital of Sichuan University from January 2014 to December 2015 were enrolled in this study in which they underwent pneumatic reduction or hydrostatic reduction. Patients were randomized into ultrasound-guided hydrostatic or X-ray-guided pneumatic reduction group. The data collected includes demographic data, symptoms, signs, and investigations. The primary outcome of the study was the success rate of reduction. And the secondary outcomes of the study were the rates of intestinal perforations and recurrence. A total of 124 children with intussusception who had met the inclusion criteria were enrolled. The overall success rate of this study was 90.32%. Univariable analysis showed that the success rate of hydrostatic reduction with normal saline (96.77%) was significantly higher than that of pneumatic reduction with air (83.87%) (p=0.015). Perforation after reduction was found in only one of the pneumatic reduction group. The recurrence rate of intussusception in the hydrostatic reduction group was 4.84% compared with 3.23% of pneumatic reduction group. Our study found that ultrasound-guided hydrostatic reduction is a simple, safe and effective nonoperative treatment for pediatric patients suffering from intussusceptions, and should be firstly adopted in the treatment of qualified patients. Therapeutic study TYPE OF STUDY: Prospective study. Copyright © 2017 Elsevier Inc. All rights reserved.

  14. Embedded Triboelectric Active Sensors for Real-Time Pneumatic Monitoring.

    PubMed

    Fu, Xian Peng; Bu, Tian Zhao; Xi, Feng Ben; Cheng, Ting Hai; Zhang, Chi; Wang, Zhong Lin

    2017-09-20

    Pneumatic monitoring sensors have great demands for power supply in cylinder systems. Here, we present an embedded sliding triboelectric nanogenerator (TENG) in air cylinder as active sensors for position and velocity monitoring. The embedded TENG is composed of a circular poly(tetrafluoroethylene) polymer and a triangular copper electrode. The working mechanism as triboelectric active sensors and electric output performance are systematically investigated. By integrating into the pneumatic system, the embedded triboelectric active sensors have been used for real-time air pressure/flow monitoring and energy storage. Air pressures are measured from 0.04 to 0.12 MPa at a step of 0.02 MPa with a sensitivity of 49.235 V/MPa, as well as airflow from 50 to 250 L/min at a step of 50 L/min with a sensitivity of 0.002 μA·min/L. This work has first demonstrated triboelectric active sensors for pneumatic monitoring and may promote the development of TENG in intelligent pneumatic system.

  15. Challenging Pneumatic Requirements for Acoustic Testing of the Cryogenic Second Stage for the New Delta 3 Rocket

    NASA Technical Reports Server (NTRS)

    Webb, Andrew T.

    1998-01-01

    The paper describes the unique pneumatic test requirements for the acoustic and shock separation testing of the Second Stage for the new Delta III Rocket at the Goddard Space Flight Center in Greenbelt, Maryland. The testing was conducted in the 45,000 cu ft (25-feet wide by 30-feet deep by 50-foot high) Acoustic Facility. The acoustic testing required that the liquid oxygen (LOX) and liquid hydrogen (LH2) tanks be filled with enough liquid nitrogen (LN2) to simulate launch fuel masses during testing. The challenge for this test dealt with designing, procuring, and fabricating the pneumatic supply systems for quick assembly while maintaining the purity requirements and minimizing costs. The pneumatic systems were designed to fill and drain the both LOX and LH2 tanks as well as to operate the fill/drain and vent valves for each of the tanks. The test criteria for the pneumatic sub-systems consisted of function, cleanliness, availability, and cost. The first criteria, function, required the tanks to be filled and drained in an efficient manner while preventing them from seeing pressures greater than 9 psig which would add a pressure cycle to the tank. An LN2 tanker, borrowed from another NASA facility, served as the pre-cool and drain tanker. Pre-cooling the tanks allowed for more efficient and cost effective transfer from the LN2 delivery tankers. Helium gas, supplied from a high purity tube trailer, was used to pressurize the vapor space above the LN2 pushing it into the drain tanker. The tube trailer also supplied high pressure helium to the vehicle for valve control and component purges. Cleanliness was maintained by proper component selection, end-use particle filtration, and any on-site cleaning determined necessary by testing. In order to meet the availability/cost juggling act, products designed for LOX delivery systems were procured to ensure system compatibility while off the shelf valves and tubing designed for the semiconductor industry were procured for the gas systems.

  16. VELoCiRaPTORS.

    NASA Astrophysics Data System (ADS)

    Lundgren, J.; Esham, B.; Padalino, S. J.; Sangster, T. C.; Glebov, V.

    2007-11-01

    The Venting and Exhausting of Low Level Air Contaminants in the Rapid Pneumatic Transport of Radioactive Samples (VELoCiRaPTORS) system is constructed to transport radioactive materials quickly and safely at the NIF. A radioactive sample will be placed inside a carrier that is transported via an airflow system produced by controlled differential pressure. Midway through the transportation process, the carrier will be stopped and vented by a powered exhaust blower which will remove radioactive gases within the transport carrier. A Geiger counter will monitor the activity of the exhaust gas to ensure that it is below acceptable levels. If the radiation level is sufficient, the carrier will pass through the remainder of the system, pneumatically braking at the counting station. The complete design will run manually or automatically with control software. Tests were performed using an inactive carrier to determine possible transportation problems. The system underwent many consecutive trials without failure. VELoCiRaPTORS is a prototype of a system that could be installed at both the Laboratory for Laser Energetics at the University of Rochester and the National Ignition Facility at LLNL.

  17. Pneumatic Regolith Transfer Systems for In Situ Resource Utilization

    NASA Technical Reports Server (NTRS)

    Mueller, R. P.; Townsend, I. I.; Mantovani, J. G.; Zacny, Kris A.; Craft, Jack

    2010-01-01

    This slide presentation reviews the testing of a pneumatic system for transfering regolith, to be used for In Situ Resource Utilization (ISRU). Using both the simulated microgravity of parabolic flight and ground testing, the tests demonstrated that lunar regolith can be conveyed pneumatically into a simulated ISRU oxygen production plant reactor. The ground testing also demonstrated that the regolith can be expelled from the ISRU reactor for disposal or for other resource processing.

  18. Integration of a mechanical forebody vortex control system into the F-15

    NASA Technical Reports Server (NTRS)

    Boalbey, Richard E.; Citurs, Kevin D.; Ely, Wayne L.; Harbaugh, Stephen P.; Hollingsworth, William B.; Phillips, Ronald L.

    1994-01-01

    The goal of the F-15 Forebody Vortex Control (FVC) program is to develop a production FVC system for the F-15. The system may consist of either a mechanically actuated device such as the strakes developed for the HARV program, or a pneumatic device such as the port blowing system being tested on the X-29. Both types of systems are being evaluated under this program. Background information on the F-15 and a description and overview of forebody vortex controls (FVC) will be presented.

  19. Titan 3E/Centaur D-1T Systems Summary

    NASA Technical Reports Server (NTRS)

    1973-01-01

    A systems and operational summary of the Titan 3E/Centaur D-1T program is presented which describes vehicle assembly facilities, launch facilities, and management responsibilities, and also provides detailed information on the following separate systems: (1) mechanical systems, including structural components, insulation, propulsion units, reaction control, thrust vector control, hydraulic systems, and pneumatic equipment; (2) astrionics systems, such as instrumentation and telemetry, navigation and guidance, C-Band tracking system, and range safety command system; (3) digital computer unit software; (4) flight control systems; (5) electrical/electronic systems; and (6) ground support equipment, including checkout equipment.

  20. OMS engine shutoff valve and actuation system design and evaluation. [for space shuttles

    NASA Technical Reports Server (NTRS)

    Wichmann, H.

    1974-01-01

    Shutoff valve and actuation system concepts that are most suitable for the Orbital Maneuvering Systems engine application were determined. Emphasis was placed on the ten year and 100 mission life requirement, propellant and propellant residue compatibility and weight. It was found that poppet or ball valves utilizing electric or electropneumatic actuation were most applicable. Preliminary design layouts of a number of valve and actuation concepts were prepared and analyzed to make the optimum concept selection. Pneumatic actuation systems were required to feature their own pneumatic supply so that for the quad redundant valve, it was necessary to include two pneumatic supply systems, one for each of the series legs of the quad redundant package. The requirement for the pneumatic package placed heavy reliability, weight, and maintenance penalties upon electropneumatic actuation systems. The two valve and actuation systems concepts selected featured electric torque motor operation and a poppet as well as a ball valve concept with a retractable seal.

  1. Pneumatic shutoff and time-delay valve operates at controlled rate

    NASA Technical Reports Server (NTRS)

    Horning, J. L.; Tomlinson, L. E.

    1966-01-01

    Shutoff and time delay valve, which incorporates a metering spool that moves at constant velocity under pneumatic pressure and spring compression, increases fluid-flow area at a uniform rate. Diaphragm areas, control cavity volume, and bleed-orifice size may be varied to give any desired combination of time delay and spool travel time.

  2. Design and Control of a Pneumatically Actuated Transtibial Prosthesis.

    PubMed

    Zheng, Hao; Shen, Xiangrong

    2015-04-01

    This paper presents the design and control of a pneumatically actuated transtibial prosthesis, which utilizes a pneumatic cylinder-type actuator to power the prosthetic ankle joint to support the user's locomotion. The pneumatic actuator has multiple advantages over the traditional electric motor, such as light weight, low cost, and high power-to-weight ratio. The objective of this work is to develop a compact and lightweight transtibial prosthesis, leveraging the multiple advantages provided by this highly competitive actuator. In this paper, the design details of the prosthesis are described, including the determination of performance specifications, the layout of the actuation mechanism, and the calculation of the torque capacity. Through the authors' design calculation, the prosthesis is able to provide sufficient range of motion and torque capacity to support the locomotion of a 75 kg individual. The controller design is also described, including the underlying biomechanical analysis and the formulation of the finite-state impedance controller. Finally, the human subject testing results are presented, with the data indicating that the prosthesis is able to generate a natural walking gait and sufficient power output for its amputee user.

  3. Design and Control of a Pneumatically Actuated Transtibial Prosthesis

    PubMed Central

    Zheng, Hao; Shen, Xiangrong

    2015-01-01

    This paper presents the design and control of a pneumatically actuated transtibial prosthesis, which utilizes a pneumatic cylinder-type actuator to power the prosthetic ankle joint to support the user's locomotion. The pneumatic actuator has multiple advantages over the traditional electric motor, such as light weight, low cost, and high power-to-weight ratio. The objective of this work is to develop a compact and lightweight transtibial prosthesis, leveraging the multiple advantages provided by this highly competitive actuator. In this paper, the design details of the prosthesis are described, including the determination of performance specifications, the layout of the actuation mechanism, and the calculation of the torque capacity. Through the authors’ design calculation, the prosthesis is able to provide sufficient range of motion and torque capacity to support the locomotion of a 75 kg individual. The controller design is also described, including the underlying biomechanical analysis and the formulation of the finite-state impedance controller. Finally, the human subject testing results are presented, with the data indicating that the prosthesis is able to generate a natural walking gait and sufficient power output for its amputee user. PMID:26146497

  4. New intraocular pressure measurement method using reflected pneumatic pressure from cornea deformed by air puff of ring-type nozzle.

    PubMed

    Kim, Hyung Jin; Seo, Yeong Ho; Kim, Byeong Hee

    2017-01-01

    In this study, a non-contact type intraocular pressure (IOP) measuring system using reflected pneumatic pressure is proposed to overcome the disadvantages of existing measurement systems. A ring-type nozzle, a key component in the proposed system, is designed via computational fluid analysis. It predicts the reflected pneumatic pressure based on the nozzle exit angle and inner and outer diameters of the nozzle, which are 30°, 7 mm, and 9 mm, respectively. Performance evaluation is conducted using artificial eyes fabricated using polydimethylsiloxane with the specifications of human eyes. The IOP of the fabricated artificial eyes is adjusted to 10, 30, and 50 mm Hg, and the reflected pneumatic pressure is measured as a function of the distance between the ring-type nozzle and artificial eye. The measured reflected pneumatic pressure is high when the measurement distance is short and eye pressure is low. The cornea of an artificial eye is significantly deformed at a low IOP, and the applied pneumatic pressure is more concentrated in front of the ring-type nozzle because of the deformed cornea. Thus, the reflected pneumatic pressure at a low IOP has more inflows into the pressure sensor inserted inside the nozzle. The sensitivity of the output based on the IOP at measurement distances between 3-5 mm is -0.0027, -0.0022, -0.0018, -0.0015, and -0.0012. Sensitivity decreases as the measurement distance increases. In addition, the reflected pneumatic pressure owing to the misalignment at the measurement distances of 3-5 mm is not affected within a range of 0.5 mm. Therefore, the measurement range is acceptable up to a 1 mm diameter from the center of an artificial eye. However, the accuracy gradually decreases as the reflected pneumatic pressure from a misalignment of 1 mm or more decreases by 26% or more.

  5. New intraocular pressure measurement method using reflected pneumatic pressure from cornea deformed by air puff of ring-type nozzle

    PubMed Central

    Kim, Hyung Jin; Seo, Yeong Ho

    2017-01-01

    In this study, a non-contact type intraocular pressure (IOP) measuring system using reflected pneumatic pressure is proposed to overcome the disadvantages of existing measurement systems. A ring-type nozzle, a key component in the proposed system, is designed via computational fluid analysis. It predicts the reflected pneumatic pressure based on the nozzle exit angle and inner and outer diameters of the nozzle, which are 30°, 7 mm, and 9 mm, respectively. Performance evaluation is conducted using artificial eyes fabricated using polydimethylsiloxane with the specifications of human eyes. The IOP of the fabricated artificial eyes is adjusted to 10, 30, and 50 mm Hg, and the reflected pneumatic pressure is measured as a function of the distance between the ring-type nozzle and artificial eye. The measured reflected pneumatic pressure is high when the measurement distance is short and eye pressure is low. The cornea of an artificial eye is significantly deformed at a low IOP, and the applied pneumatic pressure is more concentrated in front of the ring-type nozzle because of the deformed cornea. Thus, the reflected pneumatic pressure at a low IOP has more inflows into the pressure sensor inserted inside the nozzle. The sensitivity of the output based on the IOP at measurement distances between 3–5 mm is -0.0027, -0.0022, -0.0018, -0.0015, and -0.0012. Sensitivity decreases as the measurement distance increases. In addition, the reflected pneumatic pressure owing to the misalignment at the measurement distances of 3–5 mm is not affected within a range of 0.5 mm. Therefore, the measurement range is acceptable up to a 1 mm diameter from the center of an artificial eye. However, the accuracy gradually decreases as the reflected pneumatic pressure from a misalignment of 1 mm or more decreases by 26% or more. PMID:29216189

  6. Bipropellant propulsion with reciprocating pumps

    NASA Astrophysics Data System (ADS)

    Whitehead, John C.

    1993-06-01

    A pressure regulated gas generator rocket cycle with alternately pressurized pairs of reciprocating pumps offers thrust-on-demand operation with significantly lower inert mass than conventional spacecraft liquid propulsion systems. The operation of bipropellant feed systems with reciprocating pumps is explained, with consideration for both short and long term missions. There are several methods for startup and shutdown of this self-starting pump-fed system, with preference determined by thrust duty cycle and mission duration. Progress to date includes extensive development testing of components unique to this type of system, and several live tests with monopropellant hydrazine. Pneumatic pump control valves which render pistons and bellows automatically responsive to downstream liquid demand are significantly simpler than those described previously. A compact pumpset mounted to central liquid manifolds has a pair of oxidizer pumps pneumatically slaved to a pair of fuel pumps to reduce vibration. A warm gas pressure reducer for tank expulsion can eliminate any remaining need for inert gas storage.

  7. Validity and reliability of a controlled pneumatic resistance exercise device.

    PubMed

    Paulus, David C; Reynolds, Michael C; Schilling, Brian K

    2008-01-01

    During the concentric portion of the free-weight squat exercise, accelerating the mass from rest results in a fluctuation in ground reaction force. It is characterized by an initial period of force greater than the load while accelerating from rest followed by a period of force lower than the external load during negative acceleration. During the deceleration phase, less force is exerted and muscles are loaded sub-optimally. Thus, using a reduced inertia form of resistance such as pneumatics has the capability to minimize these inertial effects as well as control the force in real time to maximize the force exerted over the exercise cycle. To improve the system response of a preliminary design, a squat device was designed with a reduced mass barbell and two smaller pneumatic cylinders. The resistance was controlled by regulating cylinder pressure such that it is capable of adjusting force within a repetition to maximize force exerted during the lift. The resistance force production of the machine was statically validated with the input voltage and output force R2 =0.9997 for at four increments of the range of motion, and the intraclass correlation coefficient (ICC) between trials at the different heights equaled 0.999. The slew rate at three forces was 749.3 N/s +/- 252.3. Dynamic human subject testing showed the desired input force correlated with average and peak ground reaction force with R2 = 0.9981 and R2 = 0.9315, respectively. The ICC between desired force and average and peak ground reaction force was 0.963. Thus, the system is able to deliver constant levels of static and dynamic force with validity and reliability. Future work will be required to develop the control strategy required for real-time control, and performance testing is required to determine its efficacy.

  8. MRI-Compatible Pneumatic Robot for Transperineal Prostate Needle Placement.

    PubMed

    Fischer, Gregory S; Iordachita, Iulian; Csoma, Csaba; Tokuda, Junichi; Dimaio, Simon P; Tempany, Clare M; Hata, Nobuhiko; Fichtinger, Gabor

    2008-06-01

    Magnetic resonance imaging (MRI) can provide high-quality 3-D visualization of prostate and surrounding tissue, thus granting potential to be a superior medical imaging modality for guiding and monitoring prostatic interventions. However, the benefits cannot be readily harnessed for interventional procedures due to difficulties that surround the use of high-field (1.5T or greater) MRI. The inability to use conventional mechatronics and the confined physical space makes it extremely challenging to access the patient. We have designed a robotic assistant system that overcomes these difficulties and promises safe and reliable intraprostatic needle placement inside closed high-field MRI scanners. MRI compatibility of the robot has been evaluated under 3T MRI using standard prostate imaging sequences and average SNR loss is limited to 5%. Needle alignment accuracy of the robot under servo pneumatic control is better than 0.94 mm rms per axis. The complete system workflow has been evaluated in phantom studies with accurate visualization and targeting of five out of five 1 cm targets. The paper explains the robot mechanism and controller design, the system integration, and presents results of preliminary evaluation of the system.

  9. Adaptive robust motion trajectory tracking control of pneumatic cylinders with LuGre model-based friction compensation

    NASA Astrophysics Data System (ADS)

    Meng, Deyuan; Tao, Guoliang; Liu, Hao; Zhu, Xiaocong

    2014-07-01

    Friction compensation is particularly important for motion trajectory tracking control of pneumatic cylinders at low speed movement. However, most of the existing model-based friction compensation schemes use simple classical models, which are not enough to address applications with high-accuracy position requirements. Furthermore, the friction force in the cylinder is time-varying, and there exist rather severe unmodelled dynamics and unknown disturbances in the pneumatic system. To deal with these problems effectively, an adaptive robust controller with LuGre model-based dynamic friction compensation is constructed. The proposed controller employs on-line recursive least squares estimation (RLSE) to reduce the extent of parametric uncertainties, and utilizes the sliding mode control method to attenuate the effects of parameter estimation errors, unmodelled dynamics and disturbances. In addition, in order to realize LuGre model-based friction compensation, the modified dual-observer structure for estimating immeasurable friction internal state is developed. Therefore, a prescribed motion tracking transient performance and final tracking accuracy can be guaranteed. Since the system model uncertainties are unmatched, the recursive backstepping design technology is applied. In order to solve the conflicts between the sliding mode control design and the adaptive control design, the projection mapping is used to condition the RLSE algorithm so that the parameter estimates are kept within a known bounded convex set. Finally, the proposed controller is tested for tracking sinusoidal trajectories and smooth square trajectory under different loads and sudden disturbance. The testing results demonstrate that the achievable performance of the proposed controller is excellent and is much better than most other studies in literature. Especially when a 0.5 Hz sinusoidal trajectory is tracked, the maximum tracking error is 0.96 mm and the average tracking error is 0.45 mm. This paper constructs an adaptive robust controller which can compensate the friction force in the cylinder.

  10. Compensating for pneumatic distortion in pressure sensing devices

    NASA Technical Reports Server (NTRS)

    Whitmore, Stephen A.; Leondes, Cornelius T.

    1990-01-01

    A technique of compensating for pneumatic distortion in pressure sensing devices was developed and verified. This compensation allows conventional pressure sensing technology to obtain improved unsteady pressure measurements. Pressure distortion caused by frictional attenuation and pneumatic resonance within the sensing system makes obtaining unsteady pressure measurements by conventional sensors difficult. Most distortion occurs within the pneumatic tubing which transmits pressure impulses from the aircraft's surface to the measurement transducer. To avoid pneumatic distortion, experiment designers mount the pressure sensor at the surface of the aircraft, (called in-situ mounting). In-situ transducers cannot always fit in the available space and sometimes pneumatic tubing must be run from the aircraft's surface to the pressure transducer. A technique to measure unsteady pressure data using conventional pressure sensing technology was developed. A pneumatic distortion model is reduced to a low-order, state-variable model retaining most of the dynamic characteristics of the full model. The reduced-order model is coupled with results from minimum variance estimation theory to develop an algorithm to compensate for the effects of pneumatic distortion. Both postflight and real-time algorithms are developed and evaluated using simulated and flight data.

  11. Assessment of Pneumatic Controller Emission Measurements ...

    EPA Pesticide Factsheets

    Oil and Natural Gas (ONG) production facilities have the potential to emit greenhouse gases such as methane (CH4) and other hydrocarbons (HCs) to the atmosphere. ONG production sites have multiple emission sources including storage tank venting, enclosed combustion devices, engine exhaust, pneumatic controllers and uncontrolled leaks. Accounting for up to 37.8 percent of CH4 emissions, pneumatic controllers are one of the most significant sources of CH4 in ONG production field operations. Recent measurement studies used the only commercially-available high volume sampling (HVS) technology (Bacharach Hi Flow Sampler, Bacharach, Inc., New Kensington, PA) to quantify CH4 emission rates of pneumatic devices on ONG production pads and compare to inventory estimates. Other studies indicate that this HVS may malfunction, causing underestimates of emissions in certain scenarios encountered in ONG production and should not be used for some sources such as heavy emissions from condensate storage tanks. The HVS malfunction can occur on relatively large emissions, where the measured leak concentrations exceed 5%, and is ascribed to a sensor transition failure in the instrument. The HVS malfunction is believed to be exacerbated by several factors (large emission rates, amount of non-CH4 HCs in the emission stream, non-optimal HVS calibration frequency, firmware, and emission measurement coupling geometries). The degree to which HVS measurements of emissions from pneumatic co

  12. Performance Comparison of High-Speed Dual-Pneumatic Vitrectomy Cutters during Simulated Vitrectomy with Balanced Salt Solution.

    PubMed

    Abulon, Dina Joy K; Buboltz, David C

    2015-02-01

    To measure flow rate of balanced salt solution and IOP during simulated vitrectomy using two sets of high-speed dual-pneumatic probes. A closed-model eye system measured IOP and flow rate of a balanced salt solution through infusion cannula. The Constellation Vision System was tested with two sets of high-speed dual-pneumatic probes (UltraVit 23-gauge and enhanced 25+-gauge 5000-cpm probes; UltraVit 23-gauge and enhanced 25+-gauge 7500-cpm probes; n = 6 each) under different vacuum levels and cut rates in three duty cycle modes. In both probe sets, flow rates were dependent on cut rate with the biased open and biased closed duty cycles. Flow rates were highest with the biased open duty cycle, lower with the 50/50 duty cycle, and lowest with the biased closed duty cycle. IOP, as expected, was inversely associated with flow rate using both probe sets. The 7500-cpm probes offer greater control and customization compared with 5000-cpm probes under certain experimental conditions. At maximum cut rates, performance of 7500-cpm probes was similar to that of 5000-cpm probes, suggesting that 7500-cpm probes may be used without sacrifice of flow rate and IOP stability. Customization of vitrectomy parameters allows greater surgeon control during vitrectomy and may expand the usefulness of vitrectomy probes.

  13. Assessment of alternative dredging technologies pneumatic sediment suspension system for IMTT - Bayonne, Bayonne, New Jersey

    DOT National Transportation Integrated Search

    2001-01-16

    This report was prepared in order to document the findings of a one year environmental and hydrographic survey program conducted as part of the Air GuardTM Pneumatic Sediment Suspension System installation at IMTT in Bayonne. This system was installe...

  14. Spot-Welding Gun With Adjustable Pneumatic Spring

    NASA Technical Reports Server (NTRS)

    Burley, Richard K.

    1990-01-01

    Proposed spot-welding gun equipped with pneumatic spring, which could be bellows or piston and cylinder, exerts force independent of position along stroke. Applies accurate controlled force to joint welded, without precise positioning at critical position within stroke.

  15. Localized, stepwise template growth of functional nanowires from an amino acid-supported framework in a microfluidic chip.

    PubMed

    Puigmartí-Luis, Josep; Rubio-Martínez, Marta; Imaz, Inhar; Cvetković, Benjamin Z; Abad, Llibertat; Pérez Del Pino, Angel; Maspoch, Daniel; Amabilino, David B

    2014-01-28

    A spatially controlled synthesis of nanowire bundles of the functional crystalline coordination polymer (CP) Ag(I)TCNQ (tetracyanoquinodimethane) from previously fabricated and trapped monovalent silver CP (Ag(I)Cys (cysteine)) using a room-temperature microfluidic-assisted templated growth method is demonstrated. The incorporation of microengineered pneumatic clamps in a two-layer polydimethylsiloxane-based (PDMS) microfluidic platform was used. Apart from guiding the formation of the Ag(I)Cys coordination polymer, this microfluidic approach enables a local trapping of the in situ synthesized structures with a simple pneumatic clamp actuation. This method not only enables continuous and multiple chemical events to be conducted upon the trapped structures, but the excellent fluid handling ensures a precise chemical activation of the amino acid-supported framework in a position controlled by interface and clamp location that leads to a site-specific growth of Ag(I)TCNQ nanowire bundles. The synthesis is conducted stepwise starting with Ag(I)Cys CPs, going through silver metal, and back to a functional CP (Ag(I)TCNQ); that is, a novel microfluidic controlled ligand exchange (CP → NP → CP) is presented. Additionally, the pneumatic clamps can be employed further to integrate the conductive Ag(I)TCNQ nanowire bundles onto electrode arrays located on a surface, hence facilitating the construction of the final functional interfaced systems from solution specifically with no need for postassembly manipulation. This localized self-supported growth of functional matter from an amino acid-based CP shows how sequential localized chemistry in a fluid cell can be used to integrate molecular systems onto device platforms using a chip incorporating microengineered pneumatic tools. The control of clamp pressure and in parallel the variation of relative flow rates of source solutions permit deposition of materials at different locations on a chip that could be useful for device array preparation. The in situ reaction and washing procedures make this approach a powerful one for the fabrication of multicomponent complex nanomaterials using a soft bottom-up approach.

  16. Computer simulation of the pneumatic separator in the pneumatic-electrostatic separation system for recycling waste printed circuit boards with electronic components.

    PubMed

    Xue, Mianqiang; Xu, Zhenming

    2013-05-07

    Technologies could be integrated in different ways into automatic recycling lines for a certain kind of electronic waste according to practical requirements. In this study, a new kind of pneumatic separator with openings at the dust hooper was applied combing with electrostatic separation for recycling waste printed circuit boards. However, the flow pattern and the particles' movement behavior could not be obtained by experimental methods. To better control the separation quantity and the material size distribution, computational fluid dynamics was used to model the new pneumatic separator giving a detailed understanding of the mechanisms. Simulated results showed that the tangential velocity direction reversed with a relatively small value. Axial velocity exhibited two sharp decreases at the x axis. It is indicated that the bottom openings at the dust hopper resulted in an enormous change in the velocity profile. A new phenomenon that was named dusting was observed, which would mitigate the effect of particles with small diameter on the following electrostatic separation and avoid materials plugging caused by the waste printed circuit boards special properties effectively. The trapped materials were divided into seven grades. Experimental results showed that the mass fraction of grade 5, grade 6, and grade 7 materials were 27.54%, 15.23%, and 17.38%, respectively. Grade 1 particles' mass fraction was reduced by 80.30% compared with a traditional separator. Furthermore, the monocrystalline silicon content in silicon element in particles with a diameter of -0.091 mm was 18.9%, higher than that in the mixed materials. This study could serve as guidance for the future material flow control, automation control, waste recycling, and semiconductor storage medium destruction.

  17. The use of pneumatically generated water pressure signals for aquifer characterization

    NASA Astrophysics Data System (ADS)

    Fort, M.; Roberts, R.; Chace, D.

    2013-12-01

    The use of pneumatically generated pressure signals for aquifer characterization Hydraulic tests are the most reliable method of obtaining estimates of hydrologic properties, such as conductivity, that are essential for flow and transport modeling. The use of a sinusoidal signal for hydraulic testing is well established, with Streltsova (1988), Rasmussen (2003) and others having developed analytic solutions. Sinusoidal tests provide a unique easily distinguished signal that reduces ambiguity during analysis and we show that a sinusoidal pressure signal propagates farther into the formation than a standard slug-test signal. If a sinusoidal test is combined with a slug and/or a constant rate test, it can further reduce uncertainty in the estimated parameter values. We demonstrate how pneumatic pressure can be used to generate all three of these signals. By positioning pressure transducers both below the water level and in the head space above the water, we can monitor the total pressure acting on the formation and the changes in water level. From the changes in water level, it is possible to calculate the flow rate in and out of the well, assuming that the well diameter and water density are known. Using gas flow controllers with a Supervisory Control And Data Acquisition (SCADA) system we are able to precisely control the pressures in the well. The use of pneumatic pressure has the advantage that it requires less equipment (no pumps) and produces no water. We also show how the numerical well test analysis program nSIGHTS can be used to analyze all three types of tests simultaneously and to assess the relative contribution of each type of test to the parameter estimation. nSIGHTS was recently released as open source by Sandia National Laboratories and is available for free.

  18. Triggering vacuum capillaries for pneumatic pumping and metering liquids in point-of-care immunoassays.

    PubMed

    Weng, Kuo-Yao; Chou, Nien-Jen; Cheng, Jya-Wei

    2008-07-01

    An innovative vacuum capillary pneumatic actuation concept that can be used for point-of-care testing has been investigated. The vacuum glass capillaries are encapsulated within a laminated pouch and incorporated into the fluidic card. Vacuum glass capillaries broken by external force such as finger pressure, generate the pneumatic forces to induce liquid flow in the fluidic system. The sizes of vacuum capillary play a vital role in the pumping and metering functions of the system. The luteinizing hormone (LH) chromatographic immunoassay performances in the fluidic cards show consistency comparable to that obtained by manual micropipetting. The vacuum capillary pneumatic actuation will be applied in other complex handling step bioassays and lab-on-a-chip devices.

  19. Pneumatic pressure wave generator provides economical, simple testing of pressure transducers

    NASA Technical Reports Server (NTRS)

    Gaal, A. E.; Weldon, T. P.

    1967-01-01

    Testing device utilizes the change in pressure about a bias or reference pressure level produced by displacement of a center-driven piston in a closed cylinder. Closely controlled pneumatic pressure waves allow testing under dynamic conditions.

  20. An MRI-Guided Telesurgery System Using a Fabry-Perot Interferometry Force Sensor and a Pneumatic Haptic Device.

    PubMed

    Su, Hao; Shang, Weijian; Li, Gang; Patel, Niravkumar; Fischer, Gregory S

    2017-08-01

    This paper presents a surgical master-slave teleoperation system for percutaneous interventional procedures under continuous magnetic resonance imaging (MRI) guidance. The slave robot consists of a piezoelectrically actuated 6-degree-of-freedom (DOF) robot for needle placement with an integrated fiber optic force sensor (1-DOF axial force measurement) using the Fabry-Perot interferometry (FPI) sensing principle; it is configured to operate inside the bore of the MRI scanner during imaging. By leveraging the advantages of pneumatic and piezoelectric actuation in force and position control respectively, we have designed a pneumatically actuated master robot (haptic device) with strain gauge based force sensing that is configured to operate the slave from within the scanner room during imaging. The slave robot follows the insertion motion of the haptic device while the haptic device displays the needle insertion force as measured by the FPI sensor. Image interference evaluation demonstrates that the telesurgery system presents a signal to noise ratio reduction of less than 17% and less than 1% geometric distortion during simultaneous robot motion and imaging. Teleoperated needle insertion and rotation experiments were performed to reach 10 targets in a soft tissue-mimicking phantom with 0.70 ± 0.35 mm Cartesian space error.

  1. Ground reaction force comparison of bilateral symmetry with pneumatic resistance squat device and free weights - biomed 2009.

    PubMed

    Paulus, David C; Schilling, Brian K

    2009-01-01

    The unloading of spaceflight leads to bone and muscle atrophy, and a pneumatic resistance squat exercise countermeasure has the potential to provide optimized controllable resistance in a lightweight and compact configuration. However each end of the barbell in the proposed device is connected to a separate resistance cylinder which could lead to bilaterally asymmetric loading. Therefore, the purpose of the study is to compare the unilateral ground reaction forces (GRF) of the new squat device compared to free weights. Four previously trained men (mean +/- SD; age = 20+/-2 years, body mass = 99+/-18 kg) performed three sets of three repetitions of maximal exertion squat exercises with pneumatically controlled constant resistance and free weights each with a resistance level set to half of the body weight of each subject. Unilateral GRF data for each lifting modality at the negative to positive transition of the squat exercise was measured with a force plate under each foot. The pneumatic resistance GRF (N; mean +/- SD) was 749+/-114 on the left leg and 786+/-123 on the right leg and the free weight GRF was 786+/-114 left and 861+/-111 right resulting in a 5% difference between left and right GRF with pneumatics and 9% difference with free weights. The correlation coefficient between left and right GRF was 0.92 with pneumatics and 0.80 with free weights. Because the pneumatic device elicited more bilaterally symmetric GRF than traditional free weights, the separate resistance cylinders are an acceptable design configuration.

  2. 46 CFR 76.05-1 - Fire detecting systems.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... fitted with an automatic sprinkling system, except in relatively incombustible spaces. 2 Sprinkler heads....1 Offices, lockers, and isolated storerooms Electric, pneumatic, or automatic sprinkling1 Do.1 Public spaces None required with 20-minute patrol. Electric, pneumatic, or automatic sprinkling with 1...

  3. 46 CFR 76.05-1 - Fire detecting systems.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... fitted with an automatic sprinkling system, except in relatively incombustible spaces. 2 Sprinkler heads....1 Offices, lockers, and isolated storerooms Electric, pneumatic, or automatic sprinkling1 Do.1 Public spaces None required with 20-minute patrol. Electric, pneumatic, or automatic sprinkling with 1...

  4. Pressure Response of Various Gases in a Pneumatic Resistance Capacitance System and Pipe

    NASA Astrophysics Data System (ADS)

    Peng, J.; Youn, C.; Tadano, K.; Kagawa, T.

    2017-10-01

    City gas, such as propane and methane, is widely used as a fuel in households and factories. Recently, hydrogen as a clean and efficient fuel has been proposed for fuel cell vehicles. However, few studies have investigated pressure control and response of gases considering their properties. This study investigated the static flow rate characteristics in an orifice with four gases—air, propane, methane, and hydrogen. Then, a pressure response experiment was performed using a pneumatic resistance capacitance system comprising an isothermal chamber and a nozzle flapper, and the time constant of the pressure response with various gases was analysed with a mathematical model. The simulation results agreed with the experimental data. Finally, the differences in pressure propagation in a pipe with various gases were explicated by a pressure response experiment. The results showed that the pressure response speed of hydrogen is faster than that of the other three gases because of its small molecular weight. Therefore, the pressure control equipment of hydrogen needs a high response speed.

  5. Efficiency of a pneumatic device in controlling cuff pressure of polyurethane-cuffed tracheal tubes: a randomized controlled study

    PubMed Central

    2013-01-01

    Background The primary objective of this study was to determine the efficiency of a pneumatic device in controlling cuff pressure (Pcuff) in patients intubated with polyurethane-cuffed tracheal tubes. Secondary objectives were to determine the impact of continuous control of Pcuff, and cuff shape on microaspiration of gastric contents. Methods Prospective randomized controlled study. All patients requiring intubation and mechanical ventilation ≥48 h were eligible. The first 32 patients were intubated with tapered polyurethane-cuffed, and the 32 following patients were intubated with cylindrical polyurethane-cuffed tracheal tubes. Patients randomly received 24 h of continuous control of Pcuff using a pneumatic device (Nosten®), and 24 h of routine care of Pcuff using a manometer. Target Pcuff was 25 cmH2O. Pcuff was continuously recorded, and pepsin was quantitatively measured in all tracheal aspirates during these periods. Results The pneumatic device was efficient in controlling Pcuff (med [IQ] 26 [24, 28] vs 22 [20, 28] cmH2O, during continuous control of Pcuff and routine care, respectively; p = 0.017). In addition, percentage of patients with underinflation (31% vs 68%) or overinflation (53% vs 100%) of tracheal cuff, and percentage of time spent with underinflation (0.9 [0, 17] vs 14% [4, 30]) or overinflation (0 [0, 2] vs 32% [9, 54]) were significantly (p < 0.001) reduced during continuous control of Pcuff compared with routine care. No significant difference was found in microaspiration of gastric content between continuous control of Pcuff compared with routine care, or between patients intubated with tapered compared with cylindrical polyurethane-cuffed tracheal tubes. Conclusion The pneumatic device was efficient in controlling Pcuff in critically ill patients intubated with polyurethane-cuffed tracheal tubes. Trial registration The Australian New Zealand Clinical Trials Registry (NCT01351259) PMID:24369057

  6. Fast-acting valve actuator

    DOEpatents

    Cho, Nakwon

    1980-01-01

    A fast-acting valve actuator utilizes a spring driven pneumatically loaded piston to drive a valve gate. Rapid exhaust of pressurized gas from the pneumatically loaded side of the piston facilitates an extremely rapid piston stroke. A flexible selector diaphragm opens and closes an exhaust port in response to pressure differentials created by energizing and de-energizing a solenoid which controls the pneumatic input to the actuator as well as selectively providing a venting action to one side of the selector diaphragm.

  7. 49 CFR 232.103 - General requirements for all train brake systems.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... pneumatic technology, the integrity of the train line shall be monitored by the brake control system. (c) A... train shall not move if less than 85 percent of the cars in that train have operative and effective brakes. (f) Each car in a train shall have its air brakes in effective operating condition unless the car...

  8. High-Speed RaPToRS

    NASA Astrophysics Data System (ADS)

    Henchen, Robert; Esham, Benjamin; Becker, William; Pogozelski, Edward; Padalino, Stephen; Sangster, Thomas; Glebov, Vladimir

    2008-11-01

    The High-Speed Rapid Pneumatic Transport of Radioactive Samples (HS-RaPToRS) system, designed to quickly and safely move radioactive materials, was assembled and tested at the Mercury facility of the Naval Research Laboratory (NRL) in Washington D.C. A sample, which is placed inside a four-inch-diameter carrier, is activated before being transported through a PVC tube via airflow. The carrier travels from the reaction chamber to the end station where it pneumatically brakes prior to the gate. A magnetic latch releases the gate when the carrier arrives and comes to rest. The airflow, optical carrier-monitoring devices, and end gate are controlled manually or automatically with LabView software. The installation and testing of the RaPToRS system at NRL was successfully completed with transport times of less than 3 seconds. The speed of the carrier averaged 16 m/s. Prospective facilities for similar systems include the Laboratory for Laser Energetics and the National Ignition Facility.

  9. Does Pneumatic Tube System Transport Contribute to Hemolysis in ED Blood Samples?

    PubMed Central

    Phelan, Michael P.; Reineks, Edmunds Z.; Hustey, Fredric M.; Berriochoa, Jacob P.; Podolsky, Seth R.; Meldon, Stephen; Schold, Jesse D.; Chamberlin, Janelle; Procop, Gary W.

    2016-01-01

    Introduction Our goal was to determine if the hemolysis among blood samples obtained in an emergency department and then sent to the laboratory in a pneumatic tube system was different from those in samples that were hand-carried. Methods The hemolysis index is measured on all samples submitted for potassium analysis. We queried our hospital laboratory database system (SunQuest®) for potassium results for specimens obtained between January 2014 and July 2014. From facility maintenance records, we identified periods of system downtime, during which specimens were hand-carried to the laboratory. Results During the study period, 15,851 blood specimens were transported via our pneumatic tube system and 92 samples were hand delivered. The proportions of hemolyzed specimens in the two groups were not significantly different (13.6% vs. 13.1% [p=0.90]). Results were consistent when the criterion was limited to gross (3.3% vs 3.3% [p=0.99]) or mild (10.3% vs 9.8% [p=0.88]) hemolysis. The hemolysis rate showed minimal variation during the study period (12.6%–14.6%). Conclusion We found no statistical difference in the percentages of hemolyzed specimens transported by a pneumatic tube system or hand delivered to the laboratory. Certain features of pneumatic tube systems might contribute to hemolysis (e.g., speed, distance, packing material). Since each system is unique in design, we encourage medical facilities to consider whether their method of transport might contribute to hemolysis in samples obtained in the emergency department. PMID:27625719

  10. Does Pneumatic Tube System Transport Contribute to Hemolysis in ED Blood Samples?

    PubMed

    Phelan, Michael P; Reineks, Edmunds Z; Hustey, Fredric M; Berriochoa, Jacob P; Podolsky, Seth R; Meldon, Stephen; Schold, Jesse D; Chamberlin, Janelle; Procop, Gary W

    2016-09-01

    Our goal was to determine if the hemolysis among blood samples obtained in an emergency department and then sent to the laboratory in a pneumatic tube system was different from those in samples that were hand-carried. The hemolysis index is measured on all samples submitted for potassium analysis. We queried our hospital laboratory database system (SunQuest(®)) for potassium results for specimens obtained between January 2014 and July 2014. From facility maintenance records, we identified periods of system downtime, during which specimens were hand-carried to the laboratory. During the study period, 15,851 blood specimens were transported via our pneumatic tube system and 92 samples were hand delivered. The proportions of hemolyzed specimens in the two groups were not significantly different (13.6% vs. 13.1% [p=0.90]). Results were consistent when the criterion was limited to gross (3.3% vs 3.3% [p=0.99]) or mild (10.3% vs 9.8% [p=0.88]) hemolysis. The hemolysis rate showed minimal variation during the study period (12.6%-14.6%). We found no statistical difference in the percentages of hemolyzed specimens transported by a pneumatic tube system or hand delivered to the laboratory. Certain features of pneumatic tube systems might contribute to hemolysis (e.g., speed, distance, packing material). Since each system is unique in design, we encourage medical facilities to consider whether their method of transport might contribute to hemolysis in samples obtained in the emergency department.

  11. Series Pneumatic Artificial Muscles (sPAMs) and Application to a Soft Continuum Robot.

    PubMed

    Greer, Joseph D; Morimoto, Tania K; Okamura, Allison M; Hawkes, Elliot W

    2017-01-01

    We describe a new series pneumatic artificial muscle (sPAM) and its application as an actuator for a soft continuum robot. The robot consists of three sPAMs arranged radially round a tubular pneumatic backbone. Analogous to tendons, the sPAMs exert a tension force on the robot's pneumatic backbone, causing bending that is approximately constant curvature. Unlike a traditional tendon driven continuum robot, the robot is entirely soft and contains no hard components, making it safer for human interaction. Models of both the sPAM and soft continuum robot kinematics are presented and experimentally verified. We found a mean position accuracy of 5.5 cm for predicting the end-effector position of a 42 cm long robot with the kinematic model. Finally, closed-loop control is demonstrated using an eye-in-hand visual servo control law which provides a simple interface for operation by a human. The soft continuum robot with closed-loop control was found to have a step-response rise time and settling time of less than two seconds.

  12. Series Pneumatic Artificial Muscles (sPAMs) and Application to a Soft Continuum Robot

    PubMed Central

    Greer, Joseph D.; Morimoto, Tania K.; Okamura, Allison M.; Hawkes, Elliot W.

    2017-01-01

    We describe a new series pneumatic artificial muscle (sPAM) and its application as an actuator for a soft continuum robot. The robot consists of three sPAMs arranged radially round a tubular pneumatic backbone. Analogous to tendons, the sPAMs exert a tension force on the robot’s pneumatic backbone, causing bending that is approximately constant curvature. Unlike a traditional tendon driven continuum robot, the robot is entirely soft and contains no hard components, making it safer for human interaction. Models of both the sPAM and soft continuum robot kinematics are presented and experimentally verified. We found a mean position accuracy of 5.5 cm for predicting the end-effector position of a 42 cm long robot with the kinematic model. Finally, closed-loop control is demonstrated using an eye-in-hand visual servo control law which provides a simple interface for operation by a human. The soft continuum robot with closed-loop control was found to have a step-response rise time and settling time of less than two seconds. PMID:29379672

  13. 46 CFR 108.409 - Location and spacing of tubing in pneumatic fire detection system.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 4 2013-10-01 2013-10-01 false Location and spacing of tubing in pneumatic fire detection system. 108.409 Section 108.409 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS DESIGN AND EQUIPMENT Fire Extinguishing Systems § 108.409 Location...

  14. 46 CFR 108.409 - Location and spacing of tubing in pneumatic fire detection system.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 4 2012-10-01 2012-10-01 false Location and spacing of tubing in pneumatic fire detection system. 108.409 Section 108.409 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS DESIGN AND EQUIPMENT Fire Extinguishing Systems § 108.409 Location...

  15. 46 CFR 108.409 - Location and spacing of tubing in pneumatic fire detection system.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 4 2014-10-01 2014-10-01 false Location and spacing of tubing in pneumatic fire detection system. 108.409 Section 108.409 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS DESIGN AND EQUIPMENT Fire Extinguishing Systems § 108.409 Location...

  16. 46 CFR 108.409 - Location and spacing of tubing in pneumatic fire detection system.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 4 2011-10-01 2011-10-01 false Location and spacing of tubing in pneumatic fire detection system. 108.409 Section 108.409 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS DESIGN AND EQUIPMENT Fire Extinguishing Systems § 108.409 Location...

  17. Experimental Verification of a Pneumatic Transport System for the Rapid Evacuation of Tunnels, Part II - Test Program

    DOT National Transportation Integrated Search

    1978-12-01

    This study is the final phase of a muck pipeline program begun in 1973. The objective of the study was to evaluate a pneumatic pipeline system for muck haulage from a tunnel excavated by a tunnel boring machine. The system was comprised of a muck pre...

  18. Successful MPPF Pneumatics Verification and Validation Testing

    NASA Image and Video Library

    2017-03-28

    Engineers and technicians completed verification and validation testing of several pneumatic systems inside and outside the Multi-Payload Processing Facility (MPPF) at NASA's Kennedy Space Center in Florida. In view is the service platform for Orion spacecraft processing. The MPPF will be used for offline processing and fueling of the Orion spacecraft and service module stack before launch. Orion also will be de-serviced in the MPPF after a mission. The Ground Systems Development and Operations Program (GSDO) is overseeing upgrades to the facility. The Engineering Directorate led the recent pneumatic tests.

  19. Successful MPPF Pneumatics Verification and Validation Testing

    NASA Image and Video Library

    2017-03-28

    Engineers and technicians completed verification and validation testing of several pneumatic systems inside and outside the Multi-Payload Processing Facility (MPPF) at NASA's Kennedy Space Center in Florida. In view is the top level of the service platform for Orion spacecraft processing. The MPPF will be used for offline processing and fueling of the Orion spacecraft and service module stack before launch. Orion also will be de-serviced in the MPPF after a mission. The Ground Systems Development and Operations Program (GSDO) is overseeing upgrades to the facility. The Engineering Directorate led the recent pneumatic tests.

  20. 46 CFR 162.161-4 - Construction.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ...: SPECIFICATIONS AND APPROVAL ENGINEERING EQUIPMENT Fixed Clean Agent Fire Extinguishing Systems § 162.161-4... mechanical or pneumatic means. (d) Automatically actuated systems must be released by pneumatic or fusible... actuation and have a remote backup manual mechanical actuator. (f) Each container charged with nitrogen must...

  1. 46 CFR 162.161-4 - Construction.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ...: SPECIFICATIONS AND APPROVAL ENGINEERING EQUIPMENT Fixed Clean Agent Fire Extinguishing Systems § 162.161-4... mechanical or pneumatic means. (d) Automatically actuated systems must be released by pneumatic or fusible... actuation and have a remote backup manual mechanical actuator. (f) Each container charged with nitrogen must...

  2. 46 CFR 162.161-4 - Construction.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ...: SPECIFICATIONS AND APPROVAL ENGINEERING EQUIPMENT Fixed Clean Agent Fire Extinguishing Systems § 162.161-4... mechanical or pneumatic means. (d) Automatically actuated systems must be released by pneumatic or fusible... actuation and have a remote backup manual mechanical actuator. (f) Each container charged with nitrogen must...

  3. A Model-Based Prognostics Approach Applied to Pneumatic Valves

    NASA Technical Reports Server (NTRS)

    Daigle, Matthew J.; Goebel, Kai

    2011-01-01

    Within the area of systems health management, the task of prognostics centers on predicting when components will fail. Model-based prognostics exploits domain knowledge of the system, its components, and how they fail by casting the underlying physical phenomena in a physics-based model that is derived from first principles. Uncertainty cannot be avoided in prediction, therefore, algorithms are employed that help in managing these uncertainties. The particle filtering algorithm has become a popular choice for model-based prognostics due to its wide applicability, ease of implementation, and support for uncertainty management. We develop a general model-based prognostics methodology within a robust probabilistic framework using particle filters. As a case study, we consider a pneumatic valve from the Space Shuttle cryogenic refueling system. We develop a detailed physics-based model of the pneumatic valve, and perform comprehensive simulation experiments to illustrate our prognostics approach and evaluate its effectiveness and robustness. The approach is demonstrated using historical pneumatic valve data from the refueling system.

  4. A pneumatic cylinder driving polyhedron mobile mechanism

    NASA Astrophysics Data System (ADS)

    Ding, Wan; Kim, Sung-Chan; Yao, Yan-An

    2012-03-01

    A novel pneumatic cylinder driving polyhedron mobile mechanism is proposed in this paper. The mechanism is comprised of 5 tetrahedrons which includes a pneumatic cylinder in each edge. It locomotes by rolling and the rolling principle refers to the center of mass (CM) of the mechanism moved out of the supporting area and let it tip over through the controlling of the motion sequence of these cylinders. Firstly, the mathematical model is built to analysis the relation between the configuration and the CM of the mechanism. Then, a binary control strategy is developed to simplify and improve the control of this mobile mechanism. After that, dynamic simulation is performed to testify the analytical validity and feasibility of the rolling gaits. At last, a prototype is fabricated to achieve the rolling successfully to demonstrate the proposed concept.

  5. Sliding mode control for a two-joint coupling nonlinear system based on extended state observer.

    PubMed

    Zhao, Ling; Cheng, Haiyan; Wang, Tao

    2018-02-01

    A two-joint coupling nonlinear system driven by pneumatic artificial muscles is introduced in this paper. A sliding mode controller with extended state observer is proposed to cope with nonlinearities and disturbances for the two-joint coupling nonlinear system. In addition, convergence of the extended state observer is presented and stability analysis of the closed-loop system is also demonstrated with the sliding mode controller. Lastly, some experiments are carried out to show the reality effectiveness of the proposed method. Copyright © 2018 ISA. Published by Elsevier Ltd. All rights reserved.

  6. A Brief Study on Toxic Combustion Products of the Polymers Used in High-Pressure Oxygen Systems

    NASA Technical Reports Server (NTRS)

    Hshieh, Fu-Yu; Beeson, Harold D.

    2005-01-01

    One likely cause of polymer ignition in a high-pressure oxygen system is the adiabatic-compression heating of polymers caused by pneumatic impact. Oxidative pyrolysis or combustion of polymers in a high-pressure oxygen system could generate toxic gases. This paper investigates the feasibility of using the NASA pneumatic-impact system to conduct adiabatic-compression combustion tests and determines the toxic combustion products produced from the burning of five selected polymers. Five polymers commonly used in high-pressure oxygen systems, Zytel(Registered TradeMark) 42 (Nylon 6/6), Buna N (nitrile rubber), Witon(Registered TradeMark) A (copolymer of vinylidene fluoride and hexafluoropropylene), Neoflon(Registered TradeMark) (polychlorotrifluoroethylene), and Teflon(Registered TradeMark) (polytetrafluoroethylene), were tested in the NASA pneumatic-impact test system at 17.2-MPa oxygen pressure. The polymers were ignited and burned; combustion products were collected in a stainless-steel sample bottle and analyzed using various methods. The results show that the NASA pneumatic-impact system is an appropriate test system to conduct adiabatic-compression combustion tests and to collect combustion products for further chemical analysis. The composition of the combustion product gas generated from burning the five selected polymers are presented and discussed.

  7. Performance evaluation of a piezoactuator-based single-stage valve system subjected to high temperature

    NASA Astrophysics Data System (ADS)

    Jeon, Juncheol; Han, Chulhee; Chung, Jye Ung; Choi, Seung-Bok

    2015-01-01

    In this paper, a novel single-stage valve system activated by a piezostack actuator is proposed and experimentally evaluated at both room temperature (20 °C) and high temperature (100 °C) conditions. A hinge-lever displacement amplifier is adopted in the valve system to magnify the displacement generated from the piezostack actuator. After explaining the operating principle of the proposed piezostack-driven single-stage valve system, the geometric dimensions and mechanical properties of the valve components are discussed in details. An experimental apparatus is then manufactured to evaluate the performances of the valve system such as flow rate. The experimental apparatus consists of a heat chamber, which can regulate the temperature of the valve system and oil, pneumatic-hydraulic cylinders, a hydraulic circuit, a pneumatic circuit, electronic devices, an interface card, and a high voltage amplifier. The pneumatic-hydraulic cylinder transforms the pneumatic pressure into hydraulic pressure. The performances of the valve system regarding spool response, pressure drop, and flow rate are evaluated and presented. In addition, the performance of the valve system under high temperature condition is compared with that under room temperature condition. The experimental results are plotted in both frequency and time domains.

  8. Laboratory-based ROTEM(®) analysis: implementing pneumatic tube transport and real-time graphic transmission.

    PubMed

    Colucci, G; Giabbani, E; Barizzi, G; Urwyler, N; Alberio, L

    2011-08-01

    ROTEM(®) is considered a helpful point-of-care device to monitor blood coagulation. Centrally performed analysis is desirable but rapid transport of blood samples and real-time transmission of graphic results are an important prerequisite. The effect of sample transport through a pneumatic tube system on ROTEM(®) results is unknown. The aims of the present work were (i) to determine the influence of blood sample transport through a pneumatic tube system on ROTEM(®) parameters compared to manual transportation, and (ii) to verify whether graphic results can be transmitted on line via virtual network computing using local area network to the physician in charge of the patient. Single centre study with 30 normal volunteers. Two whole blood samples were transferred to the central haematology laboratory by either normal transport or pneumatic delivery. EXTEM, INTEM, FIBTEM and APTEM were analysed in parallel with two ROTEM(®) devices and compared. Connection between central laboratory, emergency and operating rooms was established using local area network. All collected ROTEM(®) parameters were within normal limits. No statistically significant differences between normal transport and pneumatic delivery were observed. Real-time transmission of the original ROTEM(®) curves using local area network is feasible and easy to establish. At our institution, transport of blood samples by pneumatic delivery does not influence ROTEM(®) parameters. Blood samples can be analysed centrally, and results transmitted live via virtual network computing to emergency or operating rooms. Prior to analyse blood samples centrally, the type of sample transport should be tested to exclude in vitro blood activation by local pneumatic transport system. © 2011 Blackwell Publishing Ltd.

  9. Assistive acting movement therapy devices with pneumatic rotary-type soft actuators.

    PubMed

    Wilkening, André; Baiden, David; Ivlev, Oleg

    2012-12-01

    Inherent compliance and assistive behavior are assumed to be essential properties for safe human-robot interaction. Rehabilitation robots demand the highest standards in this respect because the machine interacts directly with weak persons who are often sensitive to pain. Using novel soft fluidic actuators with rotary elastic chambers (REC actuators), compact, lightweight, and cost-effective therapeutic devices can be developed. This article describes modular design and control strategies for new assistive acting robotic devices for upper and lower extremities. Due to the inherent compliance and natural back-drivability of pneumatic REC actuators, these movement therapy devices provide gentle treatment, whereby the interaction forces between humans and the therapy device are estimated without the use of expensive force/torque sensors. An active model-based gravity compensation based on separated models of the robot and of the individual patient's extremity provides the basis for effective assistive control. The utilization of pneumatic actuators demands a special safety concept, which is merged with control algorithms to provide a sufficient level of safeness and to catch any possible system errors and/or emergency situations. A self-explanatory user interface allows for easy, intuitive handling. Prototypes are very comfortable for use due to several control routines that work in the background. Assistive devices have been tested extensively with several healthy persons; the knee/hip movement therapy device is now under clinical trials at the Clinic for Orthopaedics and Trauma Surgery at the Klinikum Stuttgart.

  10. Rod-based Fabrication of Customizable Soft Robotic Pneumatic Gripper Devices for Delicate Tissue Manipulation.

    PubMed

    Low, Jin-Huat; Yeow, Chen-Hua

    2016-08-02

    Soft compliant gripping is essential in delicate surgical manipulation for minimizing the risk of tissue grip damage caused by high stress concentrations at the point of contact. It can be achieved by complementing traditional rigid grippers with soft robotic pneumatic gripper devices. This manuscript describes a rod-based approach that combined both 3D-printing and a modified soft lithography technique to fabricate the soft pneumatic gripper. In brief, the pneumatic featureless mold with chamber component is 3D-printed and the rods were used to create the pneumatic channels that connect to the chamber. This protocol eliminates the risk of channels occluding during the sealing process and the need for external air source or related control circuit. The soft gripper consists of a chamber filled with air, and one or more gripper arms with a pneumatic channel in each arm connected to the chamber. The pneumatic channel is positioned close to the outer wall to create different stiffness in the gripper arm. Upon compression of the chamber which generates pressure on the pneumatic channel, the gripper arm will bend inward to form a close grip posture because the outer wall area is more compliant. The soft gripper can be inserted into a 3D-printed handling tool with two different control modes for chamber compression: manual gripper mode with a movable piston, and robotic gripper mode with a linear actuator. The double-arm gripper with two actuatable arms was able to pick up objects of sizes up to 2 mm and yet generate lower compressive forces as compared to elastomer-coated and non-coated rigid grippers. The feasibility of having other designs, such as single-arm or hook gripper, was also demonstrated, which further highlighted the customizability of the soft gripper device, and it's potential to be used in delicate surgical manipulation to reduce the risk of tissue grip damage.

  11. 46 CFR 58.20-25 - Tests.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 2 2013-10-01 2013-10-01 false Tests. 58.20-25 Section 58.20-25 Shipping COAST GUARD... SYSTEMS Refrigeration Machinery § 58.20-25 Tests. (a) All pressure vessels, compressors, piping, and..., hydrostatically or pneumatically. (b) No pneumatic tests in refrigeration systems aboard ships shall be made at...

  12. 46 CFR 58.20-25 - Tests.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 2 2014-10-01 2014-10-01 false Tests. 58.20-25 Section 58.20-25 Shipping COAST GUARD... SYSTEMS Refrigeration Machinery § 58.20-25 Tests. (a) All pressure vessels, compressors, piping, and..., hydrostatically or pneumatically. (b) No pneumatic tests in refrigeration systems aboard ships shall be made at...

  13. 46 CFR 58.20-25 - Tests.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 2 2012-10-01 2012-10-01 false Tests. 58.20-25 Section 58.20-25 Shipping COAST GUARD... SYSTEMS Refrigeration Machinery § 58.20-25 Tests. (a) All pressure vessels, compressors, piping, and..., hydrostatically or pneumatically. (b) No pneumatic tests in refrigeration systems aboard ships shall be made at...

  14. 46 CFR 58.20-25 - Tests.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 2 2011-10-01 2011-10-01 false Tests. 58.20-25 Section 58.20-25 Shipping COAST GUARD... SYSTEMS Refrigeration Machinery § 58.20-25 Tests. (a) All pressure vessels, compressors, piping, and..., hydrostatically or pneumatically. (b) No pneumatic tests in refrigeration systems aboard ships shall be made at...

  15. 46 CFR 58.20-25 - Tests.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 2 2010-10-01 2010-10-01 false Tests. 58.20-25 Section 58.20-25 Shipping COAST GUARD... SYSTEMS Refrigeration Machinery § 58.20-25 Tests. (a) All pressure vessels, compressors, piping, and..., hydrostatically or pneumatically. (b) No pneumatic tests in refrigeration systems aboard ships shall be made at...

  16. Pneumatic binary encoder replaces multiple solenoid system

    NASA Technical Reports Server (NTRS)

    1966-01-01

    Pneumatic binary encoder replaces solenoid system in the pilot stage of a digital actuator. The encoder operates in flip-flop manner to valve gas at either high or low pressures. By rotating the disk in a pinion-to-encoding gear ratio, six to eight adder circuits may be operated from single encoder.

  17. Propulsion system needs

    NASA Technical Reports Server (NTRS)

    Gunn, Stanley

    1991-01-01

    The needs of the designer of a solid core nuclear rocket engine are discussed. Some of the topics covered include: (1) a flight thrust module/feed system module assembly; (2) a nuclear thermal rocket (NTR), expander cycle, dual T/P; (3) turbopump operating conditions; (4) typical system parameters; (5) growth capability composite fuel elements; (6) a NTR radiation cooled nozzle extension; (7) a NFS-3B Feed System; and (8) a NTR Integrated Pneumatic-Fluidics Control System.

  18. LPT. Low power test (TAN641) interior. Heating and ventilating pneumatic ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    LPT. Low power test (TAN-641) interior. Heating and ventilating pneumatic and electrical control panel. Contract nearly complete. Photographer: Jack L. Anderson. Date: December 19, 1957. INEEL negative no. 57-6198 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID

  19. MRI-Compatible Pneumatic Robot for Transperineal Prostate Needle Placement

    PubMed Central

    Fischer, Gregory S.; Iordachita, Iulian; Csoma, Csaba; Tokuda, Junichi; DiMaio, Simon P.; Tempany, Clare M.; Hata, Nobuhiko; Fichtinger, Gabor

    2010-01-01

    Magnetic resonance imaging (MRI) can provide high-quality 3-D visualization of prostate and surrounding tissue, thus granting potential to be a superior medical imaging modality for guiding and monitoring prostatic interventions. However, the benefits cannot be readily harnessed for interventional procedures due to difficulties that surround the use of high-field (1.5T or greater) MRI. The inability to use conventional mechatronics and the confined physical space makes it extremely challenging to access the patient. We have designed a robotic assistant system that overcomes these difficulties and promises safe and reliable intraprostatic needle placement inside closed high-field MRI scanners. MRI compatibility of the robot has been evaluated under 3T MRI using standard prostate imaging sequences and average SNR loss is limited to 5%. Needle alignment accuracy of the robot under servo pneumatic control is better than 0.94 mm rms per axis. The complete system workflow has been evaluated in phantom studies with accurate visualization and targeting of five out of five 1 cm targets. The paper explains the robot mechanism and controller design, the system integration, and presents results of preliminary evaluation of the system. PMID:21057608

  20. Electronically-Scanned Pressure Sensors

    NASA Technical Reports Server (NTRS)

    Coe, C. F.; Parra, G. T.; Kauffman, R. C.

    1984-01-01

    Sensors not pneumatically switched. Electronic pressure-transducer scanning system constructed in modular form. Pressure transducer modules and analog to digital converter module small enough to fit within cavities of average-sized wind-tunnel models. All switching done electronically. Temperature controlled environment maintained within sensor modules so accuracy maintained while ambient temperature varies.

  1. Continued Development and Improvement of Pneumatic Heavy Vehicles

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Robert J. Englar

    2005-07-15

    The objective of this applied research effort led by Georgia Tech Research Institute is the application of pneumatic aerodynamic technology previously developed and patented by us to the design of an appropriate Heavy Vehicle (HV) tractor-trailer configuration, and experimental confirmation of this pneumatic configuration's improved aerodynamic characteristics. In Phases I to IV of our previous DOE program (Reference 1), GTRI has developed, patented, wind-tunnel tested and road-tested blown aerodynamic devices for Pneumatic Heavy Vehicles (PHVs) and Pneumatic Sports Utility Vehicles (PSUVs). To further advance these pneumatic technologies towards HV and SUV applications, additional Phase V tasks were included in themore » first year of a continuing DOE program (Reference 2). Based on the results of the Phase IV full-scale test programs, these Phase V tasks extended the application of pneumatic aerodynamics to include: further economy and performance improvements; increased aerodynamic stability and control; and safety of operation of Pneumatic HVs. Continued development of a Pneumatic SUV was also conducted during the Phase V program. Phase V was completed in July, 2003; its positive results towards development and confirmation of this pneumatic technology are reported in References 3 and 4. The current Phase VI of this program was incrementally funded by DOE in order to continue this technology development towards a second fuel economy test on the Pneumatic Heavy Vehicle. The objectives of this current Phase VI research and development effort (Ref. 5) fall into two categories: (1) develop improved pneumatic aerodynamic technology and configurations on smaller-scale models of the advanced Pneumatic Heavy Vehicle (PHV); and based on these findings, (2) redesign, modify, and re-test the modified full-scale PHV test vehicle. This second objective includes conduct of an on-road preliminary road test of this configuration to prepare it for a second series of SAE Type-U fuel economy evaluations, as described in Ref. 5. Both objectives are based on the pneumatic technology already developed and confirmed for DOE OHVT/OAAT in Phases I-V. This new Phase VI effort was initiated by contract amendment to the Phase V effort using carryover FY02 funds. This were conducted under a new and distinct project number, GTRI Project A-6935, separate from the Phase I-IV program. However, the two programs are closely integrated, and thus Phase VI continues with the previous program and goals.« less

  2. The Structure, Design, and Closed-Loop Motion Control of a Differential Drive Soft Robot.

    PubMed

    Wu, Pang; Jiangbei, Wang; Yanqiong, Fei

    2018-02-01

    This article presents the structure, design, and motion control of an inchworm inspired pneumatic soft robot, which can perform differential movement. This robot mainly consists of two columns of pneumatic multi-airbags (actuators), one sensor, one baseboard, front feet, and rear feet. According to the different inflation time of left and right actuators, the robot can perform both linear and turning movements. The actuators of this robot are composed of multiple airbags, and the design of the airbags is analyzed. To deal with the nonlinear performance of the soft robot, we use radial basis function neural networks to train the turning ability of this robot on three different surfaces and create a mathematical model among coefficient of friction, deflection angle, and inflation time. Then, we establish the closed-loop automatic control model using three-axis electronic compass sensor. Finally, the automatic control model is verified by linear and turning movement experiments. According to the experiment, the robot can finish the linear and turning movements under the closed-loop control system.

  3. [Development of an automatic pneumatic tourniquet system that determines pressures in synchrony with systolic blood pressure].

    PubMed

    Liu, Hongyun; Li, Kaiyuan; Zhang, Zhengbo; Guo, Junyan; Wang, Weidong

    2012-11-01

    The correlation coefficients between arterial occlusion pressure and systolic blood pressure, diastolic blood pressure, limb circumference, body mass etc were obtained through healthy volunteer experiments, in which tourniquet were applied on upper/lower extremities. The prediction equations were derived from the data of experiments by multiple regression analysis. Based on the microprocessor C8051F340, a new pneumatic tourniquet system that can determine tourniquet pressure in synchrony with systolic blood pressure was developed and verified the function and stability of designed system. Results showed that the pneumatic tourniquet which automatically adjusts occlusion pressure in accordance with systolic blood pressure could stop the flow of blood to get a bloodless field.

  4. MBM fuel feeding system design and evaluation for FBG pilot plant

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Campbell, William A., E-mail: bill.campbell@usask.ca; Fonstad, Terry; Pugsley, Todd

    2012-06-15

    Highlights: Black-Right-Pointing-Pointer A 1-5 g/s fuel feeding system for pilot scale FBG was designed, built and tested. Black-Right-Pointing-Pointer Multiple conveying stages improve pressure balancing, flow control and stability. Black-Right-Pointing-Pointer Secondary conveyor stage reduced output irregularity from 47% to 15%. Black-Right-Pointing-Pointer Pneumatic air sparging effective in dealing with poor flow ability of MBM powder. Black-Right-Pointing-Pointer Pneumatic injection port plugs with char at gasification temperature of 850 Degree-Sign C. - Abstract: A biomass fuel feeding system has been designed, constructed and evaluated for a fluidized bed gasifier (FBG) pilot plant at the University of Saskatchewan (Saskatoon, SK, Canada). The system was designedmore » for meat and bone meal (MBM) to be injected into the gasifier at a mass flow-rate range of 1-5 g/s. The designed system consists of two stages of screw conveyors, including a metering stage which controlled the flow-rate of fuel, a rotary airlock and an injection conveyor stage, which delivered that fuel at a consistent rate to the FBG. The rotary airlock which was placed between these conveyors, proved unable to maintain a pressure seal, thus the entire conveying system was sealed and pressurized. A pneumatic injection nozzle was also fabricated, tested and fitted to the end of the injection conveyor for direct injection and dispersal into the fluidized bed. The 150 mm metering screw conveyor was shown to effectively control the mass output rate of the system, across a fuel output range of 1-25 g/s, while the addition of the 50 mm injection screw conveyor reduced the irregularity (error) of the system output rate from 47% to 15%. Although material plugging was found to be an issue in the inlet hopper to the injection conveyor, the addition of air sparging ports and a system to pulse air into those ports was found to successfully eliminate this issue. The addition of the pneumatic injection nozzle reduced the output irregularity further to 13%, with an air supply of 50 slpm as the minimum air supply to drive this injector. After commissioning of this final system to the FBG reactor, the injection nozzle was found to plug with char however, and was subsequently removed from the system. Final operation of the reactor continues satisfactorily with the two screw conveyors operating at matching pressure with the fluidized bed, with the output rate of the system estimated based on system characteristic equations, and confirmed by static weight measurements made before and after testing. The error rate by this method is reported to be approximately 10%, which is slightly better than the estimated error rate of 15% for the conveyor system. The reliability of this measurement prediction method relies upon the relative consistency of the physical properties of MBM with respect to its bulk density and feeding characteristics.« less

  5. Evacuation of coal from hoppers/silos with low pressure pneumatic blasting systems

    NASA Technical Reports Server (NTRS)

    Fischer, J. S.

    1977-01-01

    The need for an efficient, economical, effective and quiet device for moving coal and other difficult bulk solids was recognized. Thus came the advent of the low pressure pneumatic blasting system - a very efficient means of using a small amount of plant air (up to 125 PSI) to eliminate the most troublesome material hang-ups in storage containers. This simple device has one moving part and uses approximately 3% of the air consumed by a pneumatic vibrator on the same job. The principle of operation is very simple: air stored in the unit's reservoir is expelled directly into the material via a patented quick release valve. The number, size, and placement of the blaster units on the storage vessel is determined by a series of tests to ascertain flowability of the problem material. These tests in conjunction with the hopper or silo configuration determine specification of a low pressure pneumatic blasting system. This concept has often proven effective in solving flow problems when all other means have failed.

  6. Design and Characterization of a Quasi-Passive Pneumatic Foot-Ankle Prosthesis.

    PubMed

    Lee, Jeffrey D; Mooney, Luke M; Rouse, Elliott J

    2017-07-01

    The majority of commercially available passive prosthetic feet are not capable of providing joint mechanics that match that of the intact human ankle. Due to their cantilever design, their stiffness characteristics contrast with what has been observed in the biological ankle, namely, an increase in stiffness during the stance phase of walking. In this paper, we introduce the design and control of a pneumatic foot-ankle prosthesis that attempts to provide biomimetic mechanics. The prosthesis is comprised of a pneumatic cylinder in series with a fiberglass leaf spring, and a solenoid valve to control the flow of air between the two sides of the cylinder. The solenoid valve acts as a mechanical clutch, enabling resetting of the ankle's equilibrium position. By adjusting the pressure inside the cylinder, the prosthesis can be customized to provide a range of ankle mechanics. A mechanical testing machine is used to compare the torque-angle curve of the pneumatic prosthesis with a low-profile passive prosthetic foot. Finally, data are presented of one transtibial amputee walking with the prosthesis at 1.2 m/s. The testing shows that the pneumatic prosthesis is capable of providing an appropriate range of motion as well a maximum torque of 94 Nm, while returning approximately 11.5 J of energy.

  7. Evaluation of elastomers as gasket materials in pneumatic and hydraulic systems

    NASA Technical Reports Server (NTRS)

    Bright, C. W.; Lockhart, B. J.

    1972-01-01

    In the search for superior materials from which to make gaskets for pneumatic and hydraulic systems, promising materials were selected and tested. The testing was conducted in two phases. Those materials that passed the tests of Phase 1 were tested in Phase 2, and categorized in the order of preference.

  8. A method of transmissibility design for dual-chamber pneumatic vibration isolator

    NASA Astrophysics Data System (ADS)

    Lee, Jeung-Hoon; Kim, Kwang-Joon

    2009-06-01

    Dual-chamber pneumatic vibration isolators have a wide range of applications for vibration isolation of vibration-sensitive equipment. Recent advances in precision machine tools and instruments such as medical devices and those related to nano-technology require better isolation performance, which can be efficiently achieved by precise modeling- and design- of the isolation system. This paper discusses an efficient transmissibility design method of a pneumatic vibration isolator wherein a complex stiffness model of a dual-chamber pneumatic spring developed in our previous study is employed. Three design parameters, the volume ratio between the two pneumatic chambers, the geometry of the capillary tube connecting the two pneumatic chambers, and, finally, the stiffness of the diaphragm employed for prevention of air leakage, were found to be important factors in transmissibility design. Based on a design technique that maximizes damping of the dual-chamber pneumatic spring, trade-offs among the resonance frequency of transmissibility, peak transmissibility, and transmissibility in high frequency range were found, which were not ever stated in previous researches. Furthermore, this paper discusses the negative role of the diaphragm in transmissibility design. The design method proposed in this paper is illustrated through experimental measurements.

  9. Discussion on a Potential DJ Basin Pneumatic Controller ...

    EPA Pesticide Factsheets

    ORD NRMRL and Region 8 collaborators are conducting emission measurements and method development studies on pneumatic controllers (PCs) in the Uintah Basin, Utah (and potentially in Colorado), in cooperation with Oil and Natural gas (ONG) operators. ONG operations use PCs for production process control and safety functions. PCs emit gas to the atmosphere as they operate and sometimes they malfunction and emit more than they are supposed to. Because of the very large number of PCs in use, these devices contribute significantly to greenhouse gas (GHG) and volatile organic compound (VOC) emissions. There is considerable uncertainty in levels of real-world PC emissions and measurement methods for PCs are somewhat underdeveloped. In collaboration with EPA R8, the State of Colorado, (and industry participants in Step 2), ORD NRMRL is evaluating a potential follow-on research effort to the Uinta Basin Pneumatic Controller (PC) Study. The Uinta PC Study is described in a recent APPCD Research Highlight (attached )with results summarized in “Assessment of Uinta Basin Oil and Natural Gas Well Pad Pneumatic Controller Emissions”, E. Thoma et al., Journal of Environmental Protection, 8, 394-415, (2017). doi: 10.4236/jep.2017.84029; at (http://www.scirp.org/Journal/PaperInformation.aspx?PaperID=75669). This RAP research was funded by an EPA R8 RARE and ACE Task EM 1.2 (next gen. emissions measurements). For both technical and programmatic reasons, we seek to

  10. Continued Development and Application of Circulation Control Pneumatic Technology to Advanced Transport Aircraft

    NASA Technical Reports Server (NTRS)

    Englar, Robert J.

    1998-01-01

    Personnel of the Georgia Tech Research Institute (GTRI) Aerospace and Transportation Lab have completed a four-year grant program to develop and evaluate the pneumatic aerodynamic technology known as Circulation Control (CC) or Circulation Control Wing (CCW) for advanced transport aircraft. This pneumatic technology, which employs low-level blowing from tangential slots over round or near-round trailing edges of airfoils, greatly augments the circulation around a lifting or control surface and thus enhances the aerodynamic forces and moments generated by that surface. Two-dimensional force augmentations as high as 80 times the input blowing momentum coefficient have been recorded experimentally for these blown devices, thus providing returns of 8000% on the jet momentum expended. A further benefit is the absence of moving parts such as mechanical flaps, slats, spoilers, ailerons, elevators and rudders from these pneumatic surfaces, or the use of only very small, simple, blown aerodynamic surfaces on synergistic designs which integrate the lift, drag and control surfaces. The application of these devices to advanced aircraft can offer significant benefits in their performance, efficiency, simplicity, reliability, economic cost of operation, noise reduction, and safety of flight. To further develop and evaluate this potential, this research effort was conducted by GTRI under grant for the NASA Langley Research Center, Applied Aerodynamics Division, Subsonic Aerodynamics Branch, between June 14, 1993 and May 31, 1997.

  11. 5. Photographic copy of a photograph taken from pasteup negatives ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    5. Photographic copy of a photograph taken from paste-up negatives for U.S. Army Corps of Engineers document GF-500-MCP, entitled "Grand Forks Site RLS Army Operating Drawings, Master Composite Photographs for SAFEGUARD TSE Systems and Equipment," Page 9, dated 1 September 1974 (original document and negatives in possession of U.S. Army Corps of Engineers, Huntsville, AL). Photographer unknown. View of pneumatic control panel regulating entrance to waiting room #116. The panel activated the pneumatic cylinder for opening and closing of blast doors #116 and #118. A rotary air motor actuated locking and unlocking of the doors. - Stanley R. Mickelsen Safeguard Complex, Remote Launch Operations Building, Near Service Road exit from Patrol Road, Nekoma, Cavalier County, ND

  12. Pneumatic preloaded scanning science launch latch system

    NASA Technical Reports Server (NTRS)

    Kievit, J. C.

    1979-01-01

    A relatively simple system using a preloaded pneumatic piston latch with a pyrotechnic valve release was developed. The system was the only candidate that met all the imposed requirements utilizing reliable state-of-art components. The development of the latch system from its first use on Mariner '69 Mars Flyby Spacecraft through its most recent use on the Voyager Spacecraft that will fly to Jupiter and Saturn is reviewed.

  13. The reduction of takeoff ground roll by the application of a nose gear jump strut

    NASA Technical Reports Server (NTRS)

    Eppel, Joseph C.; Maisel, Martin D.; Mcclain, J. Greer; Luce, W.

    1994-01-01

    A series of flight tests were conducted to evaluate the reduction of takeoff ground roll distance obtainable from a rapid extension of the nose gear strut. The NASA Quiet Short-haul Research Aircraft (QSRA) used for this investigation is a transport-size short take off and landing (STOL) research vehicle with a slightly swept wing that employs the upper surface blowing (USB) concept to attain the high lift levels required for its low-speed, short-field performance. Minor modifications to the conventional nose gear assembly and the addition of a high-pressure pneumatic system and a control system provided the extendable nose gear, or jump strut, capability. The limited flight test program explored the effects of thrust-to-weight ratio, wing loading, storage tank initial pressure, and control valve open time duration on the ground roll distance. The data show that a reduction of takeoff ground roll on the order of 10 percent was achieved with the use of the jump strut, as predicted. Takeoff performance with the jump strut was also found to be essentially independent of the pneumatic supply pressure and was only slightly affected by control valve open time within the range of the parameters examined.

  14. Flight investigation of the use of a nose gear jump strut to reduce takeoff ground roll distance of STOL aircraft

    NASA Technical Reports Server (NTRS)

    Eppel, Joseph C.; Hardy, Gordon; Martin, James L.

    1994-01-01

    A series of flight tests was conducted to evaluate the reduction of takeoff ground roll distance obtainable from a rapid extension of the nose gear strut. The NASA Quiet Short-haul Research Aircraft (QSRA) used for this investigation is a transport-size short takeoff and landing (STOL) research vehicle with a slightly swept wing that employs the upper surface blowing (USB) concept to attain the high lift levels required for its low speed, short-field performance. Minor modifications to the conventional nose gear assembly and the addition of a high pressure pneumatic system and a control system provided the extendible nose gear, or 'jump strut,' capability. The limited flight test program explored the effects of thrust-to-weight ratio, storage tank initial pressure, and control valve open time duration on the ground roll distance. The data show that the predicted reduction of takeoff ground roll on the order of 10 percent was achieved with the use of the jump strut. Takeoff performance with the jump strut was also found to be essentially independent of the pneumatic supply pressure and was only slightly affected by control valve open time within the range of the parameters examined.

  15. Pneumatic gap sensor and method

    DOEpatents

    Bagdal, Karl T.; King, Edward L.; Follstaedt, Donald W.

    1992-01-01

    An apparatus and method for monitoring and maintaining a predetermined width in the gap between a casting nozzle and a casting wheel, wherein the gap is monitored by means of at least one pneumatic gap sensor. The pneumatic gap sensor is mounted on the casting nozzle in proximity to the casting surface and is connected by means of a tube to a regulator and a transducer. The regulator provides a flow of gas through a restictor to the pneumatic gap sensor, and the transducer translates the changes in the gas pressure caused by the proximity of the casting wheel to the pneumatic gap sensor outlet into a signal intelligible to a control device. The relative positions of the casting nozzle and casting wheel can thereby be selectively adjusted to continually maintain a predetermined distance between their adjacent surfaces. The apparatus and method enables accurate monitoring of the actual casting gap in a simple and reliable manner resistant to the extreme temperatures and otherwise hostile casting environment.

  16. Pneumatic gap sensor and method

    DOEpatents

    Bagdal, K.T.; King, E.L.; Follstaedt, D.W.

    1992-03-03

    An apparatus and method for monitoring and maintaining a predetermined width in the gap between a casting nozzle and a casting wheel, wherein the gap is monitored by means of at least one pneumatic gap sensor. The pneumatic gap sensor is mounted on the casting nozzle in proximity to the casting surface and is connected by means of a tube to a regulator and a transducer. The regulator provides a flow of gas through a restictor to the pneumatic gap sensor, and the transducer translates the changes in the gas pressure caused by the proximity of the casting wheel to the pneumatic gap sensor outlet into a signal intelligible to a control device. The relative positions of the casting nozzle and casting wheel can thereby be selectively adjusted to continually maintain a predetermined distance between their adjacent surfaces. The apparatus and method enables accurate monitoring of the actual casting gap in a simple and reliable manner resistant to the extreme temperatures and otherwise hostile casting environment. 6 figs.

  17. Surgical bedside master console for neurosurgical robotic system.

    PubMed

    Arata, Jumpei; Kenmotsu, Hajime; Takagi, Motoki; Hori, Tatsuya; Miyagi, Takahiro; Fujimoto, Hideo; Kajita, Yasukazu; Hayashi, Yuichiro; Chinzei, Kiyoyuki; Hashizume, Makoto

    2013-01-01

    We are currently developing a neurosurgical robotic system that facilitates access to residual tumors and improves brain tumor removal surgical outcomes. The system combines conventional and robotic surgery allowing for a quick conversion between the procedures. This concept requires a new master console that can be positioned at the surgical bedside and be sterilized. The master console was developed using new technologies, such as a parallel mechanism and pneumatic sensors. The parallel mechanism is a purely passive 5-DOF (degrees of freedom) joystick based on the author's haptic research. The parallel mechanism enables motion input of conventional brain tumor removal surgery with a compact, intuitive interface that can be used in a conventional surgical environment. In addition, the pneumatic sensors implemented on the mechanism provide an intuitive interface and electrically isolate the tool parts from the mechanism so they can be easily sterilized. The 5-DOF parallel mechanism is compact (17 cm width, 19cm depth, and 15cm height), provides a 505,050 mm and 90° workspace and is highly backdrivable (0.27N of resistance force representing the surgical motion). The evaluation tests revealed that the pneumatic sensors can properly measure the suction strength, grasping force, and hand contact. In addition, an installability test showed that the master console can be used in a conventional surgical environment. The proposed master console design was shown to be feasible for operative neurosurgery based on comprehensive testing. This master console is currently being tested for master-slave control with a surgical robotic system.

  18. Does the Degree of the Mastoid Pneumatization Affect the Side of Bell Palsy?

    PubMed

    Güneş, Selçuk; Çelik, Mustafa; Çolak, Ceylan; Olgun, Burak

    2018-02-26

    The aim is to investigate the impact of degree of mastoid pneumatization on the affected side of Bell palsy (BP). Retrospective study in tertiary academic hospital. In total, 52 patients who were diagnosed with as BP were included in the study. Each patient was staged using House-Brackmann (HB) staging system. All patients underwent temporal bone computed tomography imaging. House-Brackmann scores, side of the BP, and mastoid pneumatization of all of patients were evaluated in the present study. Regarding the degree of the mastoid pneumatization, there were no significant differences between the affected side and the unaffected side (P = 0.439). The degree of the mastoid pneumatization of the affected side and the unaffected side did not differ between males and females (P = 0.918 for the affected side, P = 0.765 for the unaffected side, respectively). A negative correlation between the age and mastoid pneumatization of each side was found (P = 0.001, P = 0.025, respectively). There was no significant correlation between HB score and the degree of the mastoid pneumatization of each side (P = 0.789, P = 0.703). As a conclusion, the degree of the mastoid pneumatization is not one of the risk factors for BP. Further randomized studies with larger numbers of patients are needed to confirm these findings.

  19. Research on precise pneumatic-electric displacement sensor with large measurement range

    NASA Astrophysics Data System (ADS)

    Yin, Zhehao; Yuan, Yibao; Liu, Baoshuai

    2017-10-01

    This research mainly focuses on precise pneumatic-electric displacement sensor which has large measurement range. Under the high precision, measurement range can be expanded so that the need of high precision as well as large range can be satisfied in the field of machining inspection technology. This research was started by the analysis of pneumatic-measuring theory. Then, an gas circuit measuring system which is based on differential pressure was designed. This designed system can reach two aims: Firstly, to convert displacement signal into gas signal; Secondly, to reduce the measurement error which caused by pressure and environmental turbulence. Furthermore, in consideration of the high requirement for linearity, sensitivity and stability, the project studied the pneumatic-electric transducer which puts the SCX series pressure sensor as a key part. The main purpose of this pneumatic-electric transducer is to convert gas signal to suitable electrical signal. Lastly, a broken line subsection linearization circuit was designed, which can nonlinear correct the output characteristic curve so as to enlarge the linear measurement range. The final result could be briefly described like this: under the condition that measuring error is less than 1μm, measurement range could be extended to approximately 200μm which is much higher than the measurement range of traditional pneumatic measuring instrument. Meanwhile, it can reach higher exchangeability and stability in order to become more suitable to engineering application.

  20. Evaluation of a berth sedimentation control technology in the Kill Van Kull : the AirGuard (TM) pneumatic barrier system

    DOT National Transportation Integrated Search

    2001-01-01

    The problems associated with dredging and disposal in the New York and New Jersey harbor area over the past ten years have triggered sedimentation avoidance as being one of many possible tools in an ever-growing arsenal of dredged material management...

  1. Aircraft Fuel, Hydraulic and Pneumatic Systems (Course Outlines), Aviation Mechanics 3 (Air Frame): 9067.01.

    ERIC Educational Resources Information Center

    Dade County Public Schools, Miami, FL.

    This document presents an outline for a 135-hour course designed to familiarize the student with the operation, inspection, and repair of aircraft fuel, hydraulic, and pneumatic systems. It is designed to help the trainee master the knowledge and skills necessary to become an aviation airframe mechanic. The aviation airframe maintenance technician…

  2. The qualitative assessment of pneumatic actuators operation in terms of vibration criteria

    NASA Astrophysics Data System (ADS)

    Hetmanczyk, M. P.; Michalski, P.

    2015-11-01

    The work quality of pneumatic actuators can be assessed in terms of multiple criteria. In the case of complex systems with pneumatic actuators retained at end positions (with occurrence of piston impact in cylinder covers) the vibration criteria constitute the most reliable indicators. The paper presents an impact assessment on the operating condition of the rodless pneumatic cylinder regarding to selected vibrational symptoms. On the basis of performed analysis the authors had shown meaningful premises allowing an evaluation of the performance and tuning of end position damping piston movement with usage the most common diagnostic tools (portable vibration analyzers). The presented method is useful in tuning of parameters in industrial conditions.

  3. TOPICAL REVIEW: Pneumatic and hydraulic microactuators: a review

    NASA Astrophysics Data System (ADS)

    De Volder, Michaël; Reynaerts, Dominiek

    2010-04-01

    The development of MEMS actuators is rapidly evolving and continuously new progress in terms of efficiency, power and force output is reported. Pneumatic and hydraulic are an interesting class of microactuators that are easily overlooked. Despite the 20 years of research, and hundreds of publications on this topic, these actuators are only popular in microfluidic systems. In other MEMS applications, pneumatic and hydraulic actuators are rare in comparison with electrostatic, thermal or piezo-electric actuators. However, several studies have shown that hydraulic and pneumatic actuators deliver among the highest force and power densities at microscale. It is believed that this asset is particularly important in modern industrial and medical microsystems, and therefore, pneumatic and hydraulic actuators could start playing an increasingly important role. This paper shows an in-depth overview of the developments in this field ranging from the classic inflatable membrane actuators to more complex piston-cylinder and drag-based microdevices.

  4. Throttle pneumatic impact mechanism equipped with afterburner idle-stroke chamber

    NASA Astrophysics Data System (ADS)

    Dedov, Alexey; Frantseva, Eleanor; Dmitriev, Mikhail

    2017-01-01

    Pneumatic impact mechanisms are widely used in construction, mining and other economic sectors of a country. Such mechanisms are a base for a wide range of machines of various types and dimensions from hand-held tools to mounted piling hammers with impact energy up to 10 000 J. This paper is aimed at creation of pneumatic impact mechanism with the improved characteristics, including operation, energy use, weight and size which is especially important in space-limited working conditions. The research methods include development of computer mathematical model that can solve equations system and test a prototype model at the experimental stand. As a result of conducted research the pneumatic impact mechanism with the improved characteristics was developed. An engineering method for calculating throttle pneumatic impact mechanisms with a preset value of impact energy from 1 to 20 000 was investigated. This method allows creating percussive machines of a wide range of application.

  5. Chordwise implementation of pneumatic artificial muscles to actuate a trailing edge flap

    NASA Astrophysics Data System (ADS)

    Vocke, R. D., III; Kothera, C. S.; Wereley, N. M.

    2018-07-01

    This work describes the theoretical design and experimental validation of a rotorcraft-specific trailing edge flap powered by pneumatic artificial muscle actuators. The actuators in this work are co-located outboard on the rotor blade with the flap and arranged with a chordwise orientation where diameter and length restrictions can severely limit the operating range of the system. Techniques for addressing this configuration, such as introducing a bias contraction and mechanism optimization, are discussed and a numerical optimization is performed for an actuation system sized for implementation on a medium utility helicopter rotor. The optimized design achieves ±10° of deflection at 1/rev, and maintains at least ±2° half peak-to-peak deflection out to 10/rev, indicating that the system has the actuation authority and bandwidth necessary for both primary control and vibration/noise reduction. Portions of this paper were presented at the AHS 70th Annual Forum, Montréal, Québec, Canada, May 20–22, 2014.

  6. Design and Fabrication of Automatic Glass Cutting Machine

    NASA Astrophysics Data System (ADS)

    Veena, T. R.; Kadadevaramath, R. S.; Nagaraj, P. M.; Madhusudhan, S. V.

    2016-09-01

    This paper deals with the design and fabrication of the automatic glass or mirror cutting machine. In order to increase the accuracy of cut and production rate; and decrease the production time and accidents caused due to manual cutting of mirror or glass, this project aims at development of an automatic machine which uses a programmable logic controller (PLC) for controlling the movement of the conveyer and also to control the pneumatic circuit. In this machine, the work of the operator is to load and unload the mirror. The cutter used in this machine is carbide wheel with its cutting edge ground to a V-shaped profile. The PLC controls the pneumatic cylinder and intern actuates the cutter along the glass, a fracture layer is formed causing a mark to be formed below the fracture layer and a crack to be formed below the rib mark. The machine elements are designed using CATIA V5R20 and pneumatic circuit are designed using FESTO FLUID SIM software.

  7. Servo-controlled pneumatic pressure oscillator for respiratory impedance measurements and high-frequency ventilation.

    PubMed

    Kaczka, David W; Lutchen, Kenneth R

    2004-04-01

    The ability to provide forced oscillatory excitation of the respiratory system can be useful in mechanical impedance measurements as well as high frequency ventilation (HFV). Experimental systems currently used for generating forced oscillations are limited in their ability to provide high amplitude flows or maintain the respiratory system at a constant mean pressure during excitation. This paper presents the design and implementation of a pneumatic pressure oscillator based on a proportional solenoid valve. The device is capable of providing forced oscillatory excitations to the respiratory system over a bandwidth suitable for mechanical impedance measurements and HVF. It delivers high amplitude flows (> 1.4 l/s) and utilizes a servo-control mechanism to maintain a load at a fixed mean pressure during simultaneous oscillation. Under open-loop conditions, the device exhibited a static hysteresis of approximately 7%, while its dynamic magnitude and phase responses were flat out to 10 Hz. Broad-band measurement of total harmonic distortion was approximately 19%. Under closed-loop conditions, the oscillator was able to maintain a mechanical test load at both positive and negative mean pressures during oscillatory excitations from 0.1 to 10.0 Hz. Impedance of the test load agreed closely with theoretical predictions. We conclude that this servo-controlled oscillator can be a useful tool for respiratory impedance measurements as well as HFV.

  8. Field Testing of a Pneumatic Regolith Feed System During a 2010 ISRU Field Campaign on Mauna Kea, Hawaii

    NASA Technical Reports Server (NTRS)

    Craft, Jack; Zacny, Kris; Chu, Philip; Wilson, Jack; Santoro, Chris; Carlson, Lee; Maksymuk, Michael; Townsend, Ivan I.; Mueller, Robert P.; Mantovani, James G.

    2010-01-01

    Lunar In Situ Resource Utilization (ISRU) consists of a number of tasks starting with mining of lunar regolith, followed by the transfer of regolith to an oxygen extraction reactor and finally processing the regolith and storing of extracted oxygen. The transfer of regolith from the regolith hopper at the ground level to an oxygen extraction reactor many feet above the surface could be accomplished in different ways, including using a mechanical auger, bucket ladder system or a pneumatic system. The latter system is commonly used on earth when moving granular materials since it offers high reliability and simplicity of operation. In this paper, we describe a pneumatic regolith feed system, delivering feedstock to a Carbothermal reactor and lessons learned from deploying the system during the 2010 ISRU field campaign on the Mauna Kea, Hawaii.

  9. 40 CFR Table W - 3 of Subpart W of Part 98-Default Total Hydrocarbon Emission Factors for Onshore Natural Gas...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... Service Valve 1 6.42 Connector 5.71 Open-Ended Line 11.27 Pressure Relief Valve 2.01 Meter 2.93 Population... Pneumatic Device Vents 2 18.20 Intermittent Bleed Pneumatic Device Vents 2 2.35 1 Valves include control...

  10. 40 CFR Table W - 3 of Subpart W of Part 98-Default Total Hydrocarbon Emission Factors for Onshore Natural Gas...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... Service Valve 1 6.42 Connector 5.71 Open-Ended Line 11.27 Pressure Relief Valve 2.01 Meter 2.93 Population... Pneumatic Device Vents 2 18.20 Intermittent Bleed Pneumatic Device Vents 2 2.35 1 Valves include control...

  11. Field demonstration of two pneumatic backfilling technologies

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dyni, R.C.; Burnett, M.; Philbin, D.

    1995-12-31

    This US Bureau of Mines (USBM) report summarizes a field demonstration of pneumatic backfilling technologies conducted at the abandoned Hillside Coal and Iron Slope in Vandling, PA. Researchers demonstrated two pneumatic backfilling technologies recently developed under the USBM`s Abandoned Mine Reclamation Research Program, the Pneumatic Pipefeeder and the High-Efficiency Ejector. Both systems had previously been evaluated at the USBM`s subsidence abatement investigation laboratory near Fairchance, PA. The objective of the demonstration was to fill 100% of the abandoned tunnel with backfill stone to prevent further subsidence. The pneumatic Pipefeeder was used for 21 days, at a rate of 63 tomore » 124 t/d (69 to 136 st/d), to fill 88% of the tunnel. The High-Efficiency Ejector was used for 2 days, at a rate of 125 to 132 T/d (138 to 146 st/d) to fill the remaining 12% of the tunnel. The backfill placed by both systems was tightly compacted. The major problem encountered was wear on the polyethylene pipeline from the abrasion of the high-velocity backfill. The use of heavier steel pipe minimized the problem. A cost analysis for the entire project is given.« less

  12. Pneumatic Proboscis Heat-Flow Probe

    NASA Technical Reports Server (NTRS)

    Zacny, Kris; Hedlund, Magnus; Mumm, Eric; Shasho, Jeffrey; Chu, Philip; Kumar, Nishant

    2013-01-01

    Heat flow is a fundamental property of a planet, and provides significant constraints on the abundance of radiogenic isotopes, the thermal evolution and differentiation history, and the mechanical properties of the lithosphere. Heat-flow measurements are also essential in achieving at least four of the goals set out by the National Research Council for future lunar exploration. The heat-flow probe therefore directly addresses the goal of the Lunar Geophysical Network, which is to understand the interior structure and composition of the Moon. A key challenge for heat flow measurement is to install thermal sensors to the depths approximately equal to 3 m that are not influenced by the diurnal, annual, and longer-term fluctuations of the surface thermal environment. In addition, once deployed, the heat flow probe should cause little disturbance to the thermal regime of the surrounding regolith. A heat-flow probe system was developed that has two novel features: (1) it utilizes a pneumatic (gas) approach, excavates a hole by lofting the lunar soil out of the hole, and (2) deploys the heat flow probe, which utilizes a coiled up tape as a thermal probe to reach greater than 3-meter depth. The system is a game-changer for small lunar landers as it exhibits extremely low mass, volume, and simple deployment. The pneumatic system takes advantage of the helium gas used for pressurizing liquid propellant of the lander. Normally, helium is vented once the lander is on the surface, but it can be utilized for powering pneumatic systems. Should sufficient helium not be available, a simple gas delivery system may be taken specifically for the heat flow probe. Either way, the pneumatic heat flow probe system would be much lighter than other systems that entirely rely on the electrical power of the lander.

  13. Comparison of Hydraulic Conductivity Determinations in Co-located Conventional and Direct-Push Monitoring Wells

    DTIC Science & Technology

    2011-03-08

    pressure gauge on the pneumatic head and indicate the number of inches the water level was lowered in the well to induce the slug test. ERDC/CRREL...a pneumatic slug-test system and its major components. ERDC/CRREL TR-11-6 10 pressure gauge on the pneumatic head, which is graduated in inches...The water level changes induced by the slug test were measured with a 10-psi pressure transducer installed below the water level. An analog-to

  14. Dynamic design and control of a high-speed pneumatic jet actuator

    NASA Astrophysics Data System (ADS)

    Misyurin, S. Yu; Ivlev, V. I.; Kreinin, G. V.

    2017-12-01

    Mathematical model of an actuator, consisting of a pneumatic (gas) high-speed jet engine, transfer mechanism, and a control device used for switching the ball valve is worked out. The specific attention was paid to the transition (normalization) of the dynamic model into the dimensionless form. Its dynamic simulation criteria are determined, and dynamics study of an actuator was carried out. The simple control algorithm of relay action with a velocity feedback enabling the valve plug to be turned with a smooth nonstop and continuous approach to the final position is demonstrated

  15. 75 FR 36298 - Airworthiness Directives; McDonnell Douglas Corporation Model DC-8-31, DC-8-32, DC-8-33, DC-8-41...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-06-25

    ... Airworthiness Limitations inspections (ALIs). This proposed AD results from a design review of the fuel tank...,'' and also adds ALI 30-1 for a pneumatic system decay check to minimize the risk of hot air impingement... 5, 2010, adds ALI 28-1, ``DC-8 Alternate and Center Auxiliary Tank Fuel Pump Control Systems Check...

  16. Droning On: American Strategic Myopia Toward Unmanned Aerial Systems

    DTIC Science & Technology

    2013-12-01

    torpedo, nicknamed the “Bug.”3 This system consisted of pre-set pneumatic and electrical controls that stabilized and guided it toward...race their homemade drones around Mount Damavand.88 These competitions and DIY efforts provide short-term innovation of unmanned technologies. This...an even greater threat to the homeland comes from homegrown or lone wolf actor’s possession of unmanned technology. DIY kits aid in building drones

  17. Numerical and experimental analysis of a vibration isolator equipped with a negative stiffness system

    NASA Astrophysics Data System (ADS)

    Palomares, E.; Nieto, A. J.; Morales, A. L.; Chicharro, J. M.; Pintado, P.

    2018-02-01

    This paper presents a Negative Stiffness System (NSS) based on a set of two double-acting pneumatic linear actuators (PLA). The NSS is added to a system with a single degree of freedom, which consists of a sprung mass and a pneumatic spring. One end of each PLA is jointed to the sprung mass while the other end is jointed to the vibrating frame. In addition, the PLAs are symmetrically arranged so that they remain horizontal while the sprung mass is in static conditions. When the rear chamber is pressurised, the vertical component of the force applied by the PLAs will work against the pneumatic spring reducing the dynamic resonance frequency of the overall system. Experimental tests and simulations showed improvements regarding sprung mass isolation in comparison to the passive system without NSS, decreasing the resonance frequency by up to 58 % and improving the vibration attenuation for different experimental excitations.

  18. Design and fabrication of a prototype for an automatic transport system for transferring human and other wastes to an incinerator unit onboard spacecraft, phase A

    NASA Technical Reports Server (NTRS)

    Labak, L. J.; Remus, G. A.; Mansnerus, R.

    1971-01-01

    Three transport system concepts were experimentally evaluated for transferring human and nonhuman wastes from a collection site to an incineration unit onboard spacecraft. The operating parameters, merits, and shortcomings of a porous-pneumatic, nozzle-pneumatic, and a mechanical screw-feed system were determined. An analysis of the test data was made and a preliminary design of two prototype systems was prepared.

  19. Flight-determined lag of angle-of-attack and angle-of-sideslip sensors in the YF-12A airplane from analysis of dynamic maneuvers

    NASA Technical Reports Server (NTRS)

    Gilyard, G. B.; Belte, D.

    1974-01-01

    Magnitudes of lags in the pneumatic angle-of-attack and angle-of-sideslip sensor systems of the YF-12A airplane were determined for a variety of flight conditions by analyzing stability and control data. The three analysis techniques used are described. An apparent trend with Mach number for measurements from both of the differential-pressure sensors showed that the lag ranged from approximately 0.15 second at subsonic speed to 0.4 second at Mach 3. Because Mach number was closely related to altitude for the available flight data, the individual effects of Mach number and altitude on the lag could not be separated clearly. However, the results indicated the influence of factors other than simple pneumatic lag.

  20. Microfluidic and Label-Free Multi-Immunosensors Based on Carbon Nanotube Microelectrodes

    NASA Astrophysics Data System (ADS)

    Tsujita, Yuichi; Maehashi, Kenzo; Matsumoto, Kazuhiko; Chikae, Miyuki; Takamura, Yuzuru; Tamiya, Eiichi

    2009-06-01

    We fabricated microfluidic and label-free multi-immunosensors by the integration of carbon nanotube (CNT)-arrayed electrodes and microchannels with pneumatic micropumps made of poly(dimethylsiloxane). In the microfluidic systems, four kinds of sample solutions were transported from each liquid inlet to microchannels using six pneumatic micropumps. As a result, two kinds of antibodies were immobilized onto different CNT electrodes using the microfluidic systems. Next, two kinds of cancer markers, prostate specific antigen and human chorionic gonadotropin in phosphate buffer solution, were simultaneously detected by differential pulse voltammetry. Therefore, microfludic multi-immunosensors based on CNT electrodes and pneumatic micropumps are useful for the development of multiplex hand-held biosensors.

  1. Machine for applying a two component resin to a roadway surface

    DOEpatents

    Huszagh, Donald W.

    1985-01-01

    A portable machine for spraying two component resins onto a roadway, the machine having a pneumatic control system, including apparatus for purging the machine of mixed resin with air and then removing remaining resin with solvent. Interlocks prevent contamination of solvent and resin, and mixed resin can be purged in the event of a power failure.

  2. Machine for applying a two component resin to a roadway surface

    DOEpatents

    Huszagh, D.W.

    1984-01-01

    A portable machine for spraying two component resins onto a roadway, the machine having a pneumatic control system, including means for purging the machine of mixed resin with air and then removing remaining resin with solvent. Interlocks prevent contamination of solvent and resin, and mixed resin can be purged in the event of a power failure.

  3. Miniplate With a Bendable C-Tube Head Allows the Clinician to Alter Biomechanical Advantage in Extremely Complicated Anatomic Structure.

    PubMed

    Seo, Kyung Won; Iskenderoglu, Nur Serife; Hwang, Eui Hwan; Chung, Kyu-Rhim; Kim, Seong-Hun

    2017-05-01

    This article reports C-tube miniplates as a practical temporary anchorage device choice to treat open bite patients with maxillary sinus pneumatization. The C-tube components are titanium anchor plates and monocortical screws that are basically similar to any other miniplate systems, but it has the unique characteristic of the tube head to be malleable. The manipulation of the head part is easy due to the composition of pure titanium. The I-shaped C-tube with 3 holes and T-shaped C-tube miniplates were placed above the apices of maxillary molars as an absolute anchorage system to intrude the posterior maxilla. The bending of the tube heads assisted in reduction of severe open bite patient with maxillary sinus pneumatization. Sinus perforation during placement of skeletal anchorage system weakens stability of the anchorage and further cause complications. Placement of titanium C-tube miniplates allowed reliable skeletal anchorage and avoided maxillary sinus perforation in patients with extreme pneumatizations. Simple bending of C-tube miniplates ensured increased orthodontic intrusion force without having to replace them, and eliminated consequences such as perforation of maxillary sinus, sinusitis, soft tissue irritation, or infection. Anatomic difficulties in the placement of temporary anchorage device can be easily managed by using the bendable C-tube miniplate. It can serve as a great alternative over miniscrews or regular miniplates with reduced risk of sinus perforation and ability to bend the head portion to control orthodontic vectors and forces.

  4. U.S. ENVIRONMENTAL PROTECTION AGENCY'S SUPERFUND INNOVATIVE TECHNOLOGY EVALUATION OF PNEUMATIC FRACTURING EXTRACTION

    EPA Science Inventory

    The U.S. Environmental Protection Agency (EPA), in cooperation with Accutech Remedial Systems (ARS) and the New Jersey Institute of Technology (NJIT) performed a field demonstration of Pneumatic Fracturing Extraction (PFE) for the removal of chlorinated volatile organics (VOCS) f...

  5. An experimental microcomputer controlled system for synchronized pulsating anti-gravity suit.

    PubMed

    Moore, T W; Foley, J; Reddy, B R; Kepics, F; Jaron, D

    1987-07-01

    An experimental system to deliver synchronized external pressure pulsations to the lower body is described in this technical note. The system is designed using a microcomputer with a real time interface and an electro-pneumatic subsystem capable of delivering pressure pulses to a modified anti-G suit at a fast rate. It is versatile, containing many options for synchronizing, phasing and sequencing of the pressure pulsations and controlling the pressure level in the suit bladders. Details of its software and hardware are described along with the results of initial testing in a Dynamic Flight Simulator on human volunteers.

  6. Osteological and Soft-Tissue Evidence for Pneumatization in the Cervical Column of the Ostrich (Struthio camelus) and Observations on the Vertebral Columns of Non-Volant, Semi-Volant and Semi-Aquatic Birds

    PubMed Central

    Apostolaki, Naomi E.; Rayfield, Emily J.; Barrett, Paul M.

    2015-01-01

    Postcranial skeletal pneumaticity (PSP) is a condition most notably found in birds, but that is also present in other saurischian dinosaurs and pterosaurs. In birds, skeletal pneumatization occurs where bones are penetrated by pneumatic diverticula, membranous extensions that originate from air sacs that serve in the ventilation of the lung. Key questions that remain to be addressed include further characterizing (1) the skeletal features that can be used to infer the presence/absence and extent of PSP in birds and non-avian dinosaurs, and (2) the association between vertebral laminae and specific components of the avian respiratory system. Previous work has used vertebral features such as pneumatic foramina, fossae, and laminae to identify/infer the presence of air sacs and diverticula, and to discuss the range of possible functions of such features. Here, we tabulate pneumatic features in the vertebral column of 11 avian taxa, including the flightless ratites and selected members of semi-volant and semi-aquatic Neornithes. We investigate the associations of these osteological features with each other and, in the case of Struthio camelus, with the specific presence of pneumatic diverticula. We find that the mere presence of vertebral laminae does not indicate the presence of skeletal pneumaticity, since laminae are not always associated with pneumatic foramina or fossae. Nevertheless, laminae are more strongly developed when adjacent to foramina or fossae. In addition, membranous air sac extensions and adjacent musculature share the same attachment points on the vertebrae, rendering the use of such features for reconstructing respiratory soft tissue features ambiguous. Finally, pneumatic diverticula attach to the margins of laminae, foramina, and/or fossae prior to their intraosseous course. Similarities in PSP distribution among the examined taxa are concordant with their phylogenetic interrelationships. The possible functions of PSP are discussed in brief, based upon variation in the extent of PSP between taxa with differing ecologies. PMID:26649745

  7. Design of a Lightweight Soft Robotic Arm Using Pneumatic Artificial Muscles and Inflatable Sleeves.

    PubMed

    Ohta, Preston; Valle, Luis; King, Jonathan; Low, Kevin; Yi, Jaehyun; Atkeson, Christopher G; Park, Yong-Lae

    2018-04-01

    As robots begin to interact with humans and operate in human environments, safety becomes a major concern. Conventional robots, although reliable and consistent, can cause injury to anyone within its range of motion. Soft robotics, wherein systems are made to be soft and mechanically compliant, are thus a promising alternative due to their lightweight nature and ability to cushion impacts, but current designs often sacrifice accuracy and usefulness for safety. We, therefore, have developed a bioinspired robotic arm combining elements of rigid and soft robotics such that it exhibits the positive qualities of both, namely compliance and accuracy, while maintaining a low weight. This article describes the design of a robotic arm-wrist-hand system with seven degrees of freedom (DOFs). The shoulder and elbow each has two DOFs for two perpendicular rotational motions on each joint, and the hand has two DOFs for wrist rotations and one DOF for a grasp motion. The arm is pneumatically powered using custom-built McKibben type pneumatic artificial muscles, which are inflated and deflated using binary and proportional valves. The wrist and hand motions are actuated through servomotors. In addition to the actuators, the arm is equipped with a potentiometer in each joint for detecting joint angle changes. Simulation and experimental results for closed-loop position control are also presented in the article.

  8. ACCUTECH PNEUMATIC FRACTURING EXTRACTION AND HOT GAS INJECTION, PHASE I - APPLICATIONS ANALYSIS REPORT

    EPA Science Inventory

    This document summarizes and analyzes the results of a 4-wk evaluation of the Accutech Remedial Systems, Inc. (ARS) Pneumatic Fracturing Extraction™ (PFE™) process for increasing the removal of volatile organic contaminants from the vadose zone, particularly where the ground form...

  9. Impact of the injection dose of exhaust gases, on work parameters of combustion engine

    NASA Astrophysics Data System (ADS)

    Marek, W.; Śliwiński, K.

    2016-09-01

    This article is another one from the series in which were presented research results indicated the possible areas of application of the pneumatic injection using hot combustion gases proposed by Professor Jarnuszkiewicz. This publication present the results of the control system of exhaust gas recirculation. The main aim of this research was to determine the effect of exhaust gas recirculation to the operating parameters of the internal combustion engine on the basis of laboratory measurements. All measurements were performed at a constant engine speed. These conditions correspond to the operation of the motor operating an electrical generator. The study was conducted on the four-stroke two-cylinder engine with spark ignition. The study were specifically tested on the air injection system and therefore the selection of the rotational speed was not bound, as in conventional versions of operating parameters of the electrical machine. During the measurement there were applied criterion which used power control corresponding to the requirements of load power, at minimal values of engine speed. Recirculation value determined by the following recurrent position control valve of the injection doses inflator gas for pneumatic injection system. They were studied and recorded, the impact of dose of gases recirculation to the operating and ecological engine parameters such as power, torque, specific fuel consumption, efficiency, air fuel ratio, exhaust gas temperature and nitrogen oxides and hydrocarbons.

  10. An Ankle-Foot Orthosis Powered by Artificial Pneumatic Muscles

    PubMed Central

    Ferris, Daniel P.; Czerniecki, Joseph M.; Hannaford, Blake

    2005-01-01

    We developed a pneumatically powered orthosis for the human ankle joint. The orthosis consisted of a carbon fiber shell, hinge joint, and two artificial pneumatic muscles. One artificial pneumatic muscle provided plantar flexion torque and the second one provided dorsiflexion torque. Computer software adjusted air pressure in each artificial muscle independently so that artificial muscle force was proportional to rectified low-pass-filtered electromyography (EMG) amplitude (i.e., proportional myoelectric control). Tibialis anterior EMG activated the artificial dorsiflexor and soleus EMG activated the artificial plantar flexor. We collected joint kinematic and artificial muscle force data as one healthy participant walked on a treadmill with the orthosis. Peak plantar flexor torque provided by the orthosis was 70 Nm, and peak dorsiflexor torque provided by the orthosis was 38 Nm. The orthosis could be useful for basic science studies on human locomotion or possibly for gait rehabilitation after neurological injury. PMID:16082019

  11. Sowing simulation tests of a pneumatic drill equipped with systems aimed at reducing the emission of abrasion dust from maize dressed seed.

    PubMed

    Biocca, Marcello; Conte, Elisa; Pulcini, Patrizio; Marinelli, Enzo; Pochi, Daniele

    2011-01-01

    The utilization of dressed seed for spring sowing is a widespread practice to control some pests with reduced doses of chemical products. However some insecticides employed in maize seed dressing, namely belonging to the neonicotinoid family and fipronil, have been claimed to play a role in the decline of honeybees (Apis mellifera L.). Pneumatic drills used in maize sowing are charged with contributing to the dispersion of the abrasion dust produced by dressed seeds, favoring the contamination of the honeybee habitat. Different devices similar to air deflectors have been introduced on pneumatic drills in order to reduce dust drift. During previous field tests carried out by the authors during recent years reduction of dust concentration both in the air and at soil surface has been shown as a consequence of their application. As field tests are affected by the variability of environmental parameters (namely wind speed and direction) the results are not always reliable, comparable and of a general validity. This paper refers to a sowing simulation test system in which pneumatic drills can be tested at a fixed point under controlled conditions of the main environmental parameters. In the test area, protected by external influences, artificial wind conditions are created by means of a fan. The drill, suitably placed in the test area, operates the seed distribution "sur place" by means of an electric engine connected to the drill's driving wheel. A 22.5 m long sampling area, leeward with respect to the drill position, has been identified. Along the sampling area a series of Petri dishes has been placed, with the aim of capturing the depositing dust and providing the concentration of the active ingredients (a.i.) at ground level. At the same time, three air samplers with PTFE diskette filters have been used for the detection of the a.i. The test system has been used for the test of a pneumatic drill, equipped with and without air deflectors, using maize seed dressed with four a. i. (imidacloprid, clothianidin, thiametoxam, fipronil). The results showed regularly decreasing of the concentrations as distance increased, both in the air and at ground level. Moreover, the difference determined by the adoption of the drift reducing device (air deflectors) resulted clear and it can be quantified at around 50 % of the a.i. amounts observed without deflectors. Finally, the paper proposes a data processing method that, from the values observed at fixed point, provides the theoretical a.i. concentration behavior that would occur in field, under the same conditions of wind speed and direction and working speed. The obtained results are coherent with previous field test.

  12. Theoretical modeling of a gas clearance phase regulation mechanism for a pneumatically-driven split-Stirling-cycle cryocooler

    NASA Astrophysics Data System (ADS)

    Zhang, Cun-quan; Zhong, Cheng

    2015-03-01

    The concept of a new type of pneumatically-driven split-Stirling-cycle cryocooler with clearance-phase-adjustor is proposed. In this implementation, the gap between the phase-adjusting part and the cylinder of the spring chamber is used, instead of dry friction acting on the pneumatically-driven rod to control motion damping of the displacer and to adjust the phase difference between the compression piston and displacer. It has the advantages of easy damping adjustment, low cost, and simplified manufacturing and assembly. A theoretical model has been established to simulate its dynamic performance. The linear compressor is modeled under adiabatic conditions, and the displacement of the compression piston is experimentally rectified. The working characteristics of the compressor motor and the principal losses of cooling, including regenerator inefficiency loss, solid conduction loss, shuttle loss, pump loss and radiation loss, are taken into account. The displacer motion was modeled as a single-degree-of-freedom (SDOF) forced system. A set of governing equations can be solved numerically to simulate the cooler's performance. The simulation is useful for understanding the physical processes occurring in the cooler and for predicting the cooler's performance.

  13. Dynamic interleaved 1H/31P STEAM MRS at 3 Tesla using a pneumatic force-controlled plantar flexion exercise rig

    PubMed Central

    Meyerspeer, M.; Krššák, M.; Kemp, G.J.; Roden, M.; Moser, E.

    2016-01-01

    1 Objective To develop a measurement method for interleaved acquisition of 1H and 31P STEAM localised spectra of exercising human calf muscle. 2 Materials and Methods A nonmagnetic exercise rig with a pneumatic piston and sensors for force and pedal angle was constructed to enable plantar flexion measured in the 3 Tesla MR scanner, which holds the dual tuned (1H,31P) surface coil used for signal transmission and reception. 3 Results 31P spectra acquired in interleaved mode benefit from higher SNR (factor of 1.34± 0.06 for PCr) compared to standard acquisition due to the Nuclear Overhauser effect (NOE) and substantial PCr/Pi changes during exercise can be observed in 31P spectra. 1H spectral quality is equal to that in single mode experiments and allows Cr2 changes to be monitored. 4 Conclusion The feasibility of dynamic interleaved localised 1H and 31P spectroscopy during plantar flexion exercise has been demonstrated using a custom-built pneumatic system for muscle activation. This opens the possibility of studying the dynamics of metabolism with multi nuclear MRS in a single run. PMID:16320091

  14. POSITIONING DEVICE

    DOEpatents

    Wall, R.R.; Peterson, D.L.

    1959-09-15

    A positioner is described for a vertical reactor-control rod. The positioner comprises four grooved friction rotatable members that engage the control rod on all sides and shift it longitudinally. The four friction members are drivingly interconnected for conjoint rotation and comprise two pairs of coaxial members. The members of each pair are urged toward one another by hydraulic or pneumatic pressure and thus grip the control rod so as to hold it in any position or adjust it. Release of the by-draulic or pneumatic pressure permits springs between the friction members of each pair to force them apart, whereby the control rod moves quickly by gravity into the reactor.

  15. Impact of a pneumatic tube system transport on hemostasis parameters measurement: the experiment of Cochin universitary hospital (AP-HP, Paris, France).

    PubMed

    Calmette, Leyla; Ibrahim, Firas; Gouin, Isabelle; Horellou, Marie-Hélène; Mazoyer, Élisabeth; Fontenay, Michaela; Flaujac, Claire

    2017-02-01

    Samples transported by pneumatic tube system are submitted to forces of acceleration and deceleration which can affect laboratory parameters. At Cochin hospital, majority of samples of hemostasis, except for platelets tests, are transported by pneumatic tube system. The objective of this study was to evaluate the impact of a pneumatic tube system (PTS) transport compared to hand-delivered transport on samples and to qualify Cochin hospital PTS according to requirements of standard ISO 15189. A bibliographical study was made and showed that pneumatic tube system particularly influences platelets tests. Four citrate tubes were collected in 5 healthy volunteers in the maternity: 2 tubes were transported by PTS and 2 others were hand-delivered to the laboratory. Five coagulation tests were analyzed: prothrombine time (PT), activated partial thromboplastin time (aPTT), factor (F) V, FVIII and platelet closure time with PFA-100TM collagen/epinephrine. For each volunteer, the results obtained by PTS and by hand-delivered transport were compared with formula usually used for biological analysis retake: 2.8 x standard deviation of reproductibility variation coefficient (SH GTA 01, COFRAC). This study did not show an impact of PTS on PT, aPTT, FV and FVIII. For PFA-100TM collagen/epinephrine, we noted an impact on 2/5 volunteers. These results, in agreement with the literature, led to the conclusion that Cochin hospital PTS is in compliance to transport samples for usual coagulation tests except platelet tests. This study allowed to issue French recommendations for PTS transport of hemostasis tubes qualification available on "Groupe français d'hémostase et thrombose" Web site.

  16. Variable diameter wind turbine rotor blades

    DOEpatents

    Jamieson, Peter McKeich; Hornzee-Jones, Chris; Moroz, Emilian M.; Blakemore, Ralph W.

    2005-12-06

    A system and method for changing wind turbine rotor diameters to meet changing wind speeds and control system loads is disclosed. The rotor blades on the wind turbine are able to adjust length by extensions nested within or containing the base blade. The blades can have more than one extension in a variety of configurations. A cable winching system, a hydraulic system, a pneumatic system, inflatable or elastic extensions, and a spring-loaded jack knife deployment are some of the methods of adjustment. The extension is also protected from lightning by a grounding system.

  17. Down-hole periodic seismic generator

    DOEpatents

    Hardee, H.C.; Hills, R.G.; Striker, R.P.

    1982-10-28

    A down hole periodic seismic generator system is disclosed for transmitting variable frequency, predominantly shear-wave vibration into earth strata surrounding a borehole. The system comprises a unitary housing operably connected to a well head by support and electrical cabling and contains clamping apparatus for selectively clamping the housing to the walls of the borehole. The system further comprises a variable speed pneumatic oscillator and a self-contained pneumatic reservoir for producing a frequency-swept seismic output over a discrete frequency range.

  18. Advanced downhole periodic seismic generator

    DOEpatents

    Hardee, Harry C.; Hills, Richard G.; Striker, Richard P.

    1991-07-16

    An advanced downhole periodic seismic generator system for transmitting variable frequency, predominantly shear-wave vibration into earth strata surrounding a borehole. The system comprises a unitary housing operably connected to a well head by support and electrical cabling and contains clamping apparatus for selectively clamping the housing to the walls of the borehole. The system further comprises a variable speed pneumatic oscillator and a self-contained pneumatic reservoir for producing a frequency-swept seismic output over a discrete frequency range.

  19. Down hole periodic seismic generator

    DOEpatents

    Hardee, Harry C.; Hills, Richard G.; Striker, Richard P.

    1989-01-01

    A down hole periodic seismic generator system for transmitting variable frequency, predominantly shear-wave vibration into earth strata surrounding a borehole. The system comprises a unitary housing operably connected to a well head by support and electrical cabling and contains clamping apparatus for selectively clamping the housing to the walls of the borehole. The system further comprises a variable speed pneumatic oscillator and a self-contained pneumatic reservoir for producing a frequency-swept seismic output over a discrete frequency range.

  20. Static and dynamic stability of pneumatic vibration isolators and systems of isolators

    NASA Astrophysics Data System (ADS)

    Ryaboy, Vyacheslav M.

    2014-01-01

    Pneumatic vibration isolation is the most widespread effective method for creating vibration-free environments that are vital for precise experiments and manufacturing operations in optoelectronics, life sciences, microelectronics, nanotechnology and other areas. The modeling and design principles of a dual-chamber pneumatic vibration isolator, basically established a few decades ago, continue to attract attention of researchers. On the other hand, behavior of systems of such isolators was never explained in the literature in sufficient detail. This paper covers a range of questions essential for understanding the mechanics of pneumatic isolation systems from both design and application perspectives. The theory and a model of a single standalone isolator are presented in concise form necessary for subsequent analysis. Then the dynamics of a system of isolators supporting a payload is considered with main attention directed to two aspects of their behavior: first, the static stability of payloads with high positions of the center of gravity; second, dynamic stability of the feedback system formed by mechanical leveling valves. The direct method of calculating the maximum stable position of the center of gravity is presented and illustrated by three-dimensional stability domains; analytic formulas are given that delineate these domains. A numerical method for feedback stability analysis of self-leveling valve systems is given, and the results are compared with the analytical estimates for a single isolator. The relation between the static and dynamic phenomena is discussed.

  1. Fast force actuators for LSST primary/tertiary mirror

    NASA Astrophysics Data System (ADS)

    Hileman, Edward; Warner, Michael; Wiecha, Oliver

    2010-07-01

    The very short slew times and resulting high inertial loads imposed upon the Large Synoptic Survey Telescope (LSST) create new challenges to the primary mirror support actuators. Traditionally large borosilicate mirrors are supported by pneumatic systems, which is also the case for the LSST. These force based actuators bear the weight of the mirror and provide active figure correction, but do not define the mirror position. A set of six locating actuators (hardpoints) arranged in a hexapod fashion serve to locate the mirror. The stringent dynamic requirements demand that the force actuators must be able to counteract in real time for dynamic forces on the hardpoints during slewing to prevent excessive hardpoint loads. The support actuators must also maintain the prescribed forces accurately during tracking to maintain acceptable mirror figure. To meet these requirements, candidate pneumatic cylinders incorporating force feedback control and high speed servo valves are being tested using custom instrumentation with automatic data recording. Comparative charts are produced showing details of friction, hysteresis cycles, operating bandwidth, and temperature dependency. Extremely low power actuator controllers are being developed to avoid heat dissipation in critical portions of the mirror and also to allow for increased control capabilities at the actuator level, thus improving safety, performance, and the flexibility of the support system.

  2. Modeling and experiments on the drive characteristics of high-strength water hydraulic artificial muscles

    NASA Astrophysics Data System (ADS)

    Zhang, Zengmeng; Hou, Jiaoyi; Ning, Dayong; Gong, Xiaofeng; Gong, Yongjun

    2017-05-01

    Fluidic artificial muscles are popular in robotics and function as biomimetic actuators. Their pneumatic version has been widely investigated. A novel water hydraulic artificial muscle (WHAM) with high strength is developed in this study. WHAMs can be applied to underwater manipulators widely used in ocean development because of their environment-friendly characteristics, high force-to-weight ratio, and good bio-imitability. Therefore, the strength of WHAMs has been improved to fit the requirements of underwater environments and the work pressure of water hydraulic components. However, understanding the mechanical behaviors of WHAMs is necessary because WHAMs use work media and pressure control that are different from those used by pneumatic artificial muscles. This paper presents the static and dynamic characteristics of the WHAM system, including the water hydraulic pressure control circuit. A test system is designed and built to analyze the drive characteristics of the developed WHAM. The theoretical relationships among the amount of contraction, pressure, and output drawing force of the WHAM are tested and verified. A linearized transfer function is proposed, and the dynamic characteristics of the WHAM are investigated through simulation and inertia load experiments. Simulation results agree with the experimental results and show that the proposed model can be applied to the control of WHAM actuators.

  3. Manually Operatable On-Chip Bistable Pneumatic Microstructures for Microfluidic Manipulations

    PubMed Central

    Chen, A.; Pan, T.

    2014-01-01

    Bistable microvalves are of particular interest because of their distinct nature requiring energy consumption only during the transition between the open and closed states. This characteristic can be highly advantageous in reducing the number of external inputs and the complexity of control circuitries for microfluidic devices as contemporary lab-on-a-chip platforms are transferring from research settings to low-resource environments with high integratability and small form factor. In this paper, we first present manually operatable, on-chip bistable pneumatic microstructures (BPM) for microfluidic manipulation. The structural design and operation of the BPM devices can be readily integrated into any pneumatically powered microfluidic network consisting of pneumatic and fluidic channels. It is mainly comprised of a vacuum activation chamber (VAC) and a pressure release chamber (PRC), which users have direct control through finger pressing to switch between bistable vacuum state (VS) or atmospheric state (AS). We have integrated multiple BPM devices into a 4-to-1 microfluidic multiplexor to demonstrate on-chip digital flow switching from different sources. Furthermore, we have shown its clinical relevance in a point-of-care diagnostic chip that process blood samples to identify the distinct blood types (A/B/O) on chip. PMID:25007840

  4. Manually operatable on-chip bistable pneumatic microstructures for microfluidic manipulations.

    PubMed

    Chen, Arnold; Pan, Tingrui

    2014-09-07

    Bistable microvalves are of particular interest because of their distinct nature of requiring energy consumption only during the transition between the open and closed states. This characteristic can be highly advantageous in reducing the number of external inputs and the complexity of control circuitries since microfluidic devices as contemporary lab-on-a-chip platforms are transferring from research settings to low-resource environments with high integrability and a small form factor. In this paper, we first present manually operatable, on-chip bistable pneumatic microstructures (BPMs) for microfluidic manipulation. The structural design and operation of the BPM devices can be readily integrated into any pneumatically powered microfluidic network consisting of pneumatic and fluidic channels. It is mainly composed of a vacuum activation chamber (VAC) and a pressure release chamber (PRC), of which users have direct control through finger pressing to switch either to the bistable vacuum state (VS) or the atmospheric state (AS). We have integrated multiple BPM devices into a 4-to-1 microfluidic multiplexor to demonstrate on-chip digital flow switching from different sources. Furthermore, we have shown its clinical relevance in a point-of-care diagnostic chip that processes blood samples to identify the distinct blood types (A/B/O) on-chip.

  5. Programmable prostate palpation simulator using property-changing pneumatic bladder.

    PubMed

    Talhan, Aishwari; Jeon, Seokhee

    2018-05-01

    The currently available prostate palpation simulators are based on either a physical mock-up or pure virtual simulation. Both cases have their inherent limitations. The former lacks flexibility in presenting abnormalities and scenarios because of the static nature of the mock-up and has usability issues because the prostate model must be replaced in different scenarios. The latter has realism issues, particularly in haptic feedback, because of the very limited performance of haptic hardware and inaccurate haptic simulation. This paper presents a highly flexible and programmable simulator with high haptic fidelity. Our new approach is based on a pneumatic-driven, property-changing, silicone prostate mock-up that can be embedded in a human torso mannequin. The mock-up has seven pneumatically controlled, multi-layered bladder cells to mimic the stiffness, size, and location changes of nodules in the prostate. The size is controlled by inflating the bladder with positive pressure in the chamber, and a hard nodule can be generated using the particle jamming technique; the fine sand in the bladder becomes stiff when it is vacuumed. The programmable valves and system identification process enable us to precisely control the size and stiffness, which results in a simulator that can realistically generate many different diseases without replacing anything. The three most common abnormalities in a prostate are selected for demonstration, and multiple progressive stages of each abnormality are carefully designed based on medical data. A human perception experiment is performed by actual medical professionals and confirms that our simulator exhibits higher realism and usability than do the conventional simulators. Copyright © 2018 Elsevier Ltd. All rights reserved.

  6. Research and simulation on the rollover system of corn harvester

    NASA Astrophysics Data System (ADS)

    Li, Shizhuang; Cao, Shukun

    2017-01-01

    The structural characteristics of our country's corn harvester are narrow-track, high centroid and existence of eccentric distance, so rollover accident is easily to occur when driving in mountainous and hilly regions. In order to improve the design quality of corn harvester and enhance the security of operation, it is of great significance to research the rollover prevention system of the corn harvester. Hydro-pneumatic suspension has powerful function of adjusting the balance of automobile body and good shock absorption function. In this paper, hydro-pneumatic suspension is applied to the rollover prevention system of the corn harvester to improve the ability of anti-rollover. At last using ADAMS simulation technology to simulate the roll stability of traditional corn harvester and the corn harvester with hydro pneumatic suspension, then calculating the heeling angle in both cases.

  7. Dismantling the nuclear research reactor Thetis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Michiels, P.

    The research reactor Thetis, in service since 1967 and stopped in 2003, is part of the laboratories of the institution of nuclear science of the University of Ghent. The reactor, of the pool-type, was used as a neutron-source for the production of radio-isotopes and for activation analyses. The reactor is situated in a water pool with inner diameter of 3 m. and a depth of 7.5 m. The reactor core is situated 5.3 m under water level. Besides the reactor, the pool contains pneumatic loops, handling tools, graphite blocks for neutron moderation and other experimental equipment. The building houses storagemore » rooms for fissile material and sources, a pneumatic circuit for transportation of samples, primary and secondary cooling circuits, water cleaning resin circuits, a ventilation system and other necessary devices. Because of the experimental character of the reactor, laboratories with glove boxes and other tools were needed and are included in the dismantling program. The building is in 3 levels with a crawl-space. The ground-floor contains the ventilation installation, the purification circuits with tanks, cooling circuits and pneumatic transport system. On the first floor, around the reactor hall, the control-room, visiting area, end-station for pneumatic transport, waste-storage room, fuel storage room and the labs are located. The second floor contains a few laboratories and end stations of the two high speed transfer tubes. The lowest level of the pool is situated under ground level. The reactor has been operated at a power of 150 kW and had a max operating power of 250 kW. Belgoprocess has been selected to decommission the reactor, the labs, storage halls and associated circuits to free release the building for conventional reuse and for the removal of all its internals as legal defined. Besides the dose-rate risk and contamination risk, there is also an asbestos risk of contamination. During construction of the installation, asbestos-containing materials were used, which must be removed in controlled conditions. The ventilation system is considered free from nuclear contamination but it contains asbestos. This paper covers the organization of the dismantling work, the technical execution aspect and conclusions already known (dismantling is ongoing as this is written). (authors)« less

  8. Transient Analysis of Pressurization and Pneumatic Subsystems of the X-34 Main Propulsion System

    NASA Technical Reports Server (NTRS)

    Hedayat, A.; Knight, K. C.; Chamption, R. H., Jr.; Kennedy, Jim W. (Technical Monitor)

    2000-01-01

    Transient models for the pressurization, vent/relief, and pneumatic subsystems of the X-34 Main Propulsion System are presented and simulation of their operation within prescribed requirements are provided. First, using ROCket Engine Transient Simulation (ROCETS) program, pressurization subsystem operation was simulated and helium requirements and the ullage thermodynamic condition within each propellant tank were calculated. Then, Overpressurization scenarios of propellant tanks and the response of vent/relief valves were evaluated using ROCETS simulation of simultaneous operation of the pressurization and vent/relief subsystems by incorporating the valves data into the model. Finally, the ROCETS simulation of in-flight operation of pneumatic subsystem predicted the overall helium consumption, Inter-Propellant Seal (IPS) purge flowrate and thermodynamic conditions, and Spin Start power.

  9. Study made of pneumatic high pressure piping materials /10,000 psi/

    NASA Technical Reports Server (NTRS)

    Loeb, M. B.; Smith, J. C.

    1967-01-01

    Evaluations of five types of steel for use in high pressure pneumatic piping systems include tests for impact strength, tensile and yield strengths, elongation and reduction in area, field weldability, and cost. One type, AISI 4615, was selected as most advantageous for extensive use in future flight vehicles.

  10. Conceptual Design Study of Air Bearing/Suction Hold-Down Devices for Vertical Landing Aircraft

    DTIC Science & Technology

    1977-03-21

    Brakes are locked. (e) Pilot can control hold-down force. (f) System can be operated from ship’s power after engine shutdown. (g) Low translation... pneumatic snubbers also serve to lift the skirt to its maximum height, when the system is ietracted, by reversing the pressure in the cylinder. A bellows...drag of the Elastic Trunk System is a function of the trunk reaction against the deck (flattening) and the braking coefficient of friction. For rubber

  11. Performance of a Rotary Wing Air Brake in Supersonic Flow

    DTIC Science & Technology

    1947-05-18

    a pneumatic thrust measuring system (3) Strobotac and Audio Signal Generator for RPM measurements, (4) motion picture cameras and miscellaneous...produced by the head to keep the brake engaged. The " pneumatic thrust measuring system1* utilised the bellows described above to oppose the drag force...a brake , to prevent its rotation when desired. To release the brake it was necessary to inflate the internal thrust bellows, thereby disengaging

  12. F/A-18 forebody vortex control. Volume 1: Static tests

    NASA Technical Reports Server (NTRS)

    Kramer, Brian R.; Suarez, Carlos J.; Malcolm, Gerald N.; Ayers, Bert F.

    1994-01-01

    A wind tunnel test was conducted on a six percent model of the F/A-18 at the NASA Ames 7 X 10-Foot Low Speed Wind Tunnel. The primary objective of the test was to evaluate several forebody vortex control configurations at high angles of attack in order to determine the most effective method of obtaining well behaved yawing moments, in preparation for the rotary balance test. Both mechanical and pneumatic systems were tested. Single and dual rotating nose tip strakes and a vertical nose strake were tested at different sizes and deflections. A series of jet blowing configurations were located at various fuselage stations, azimuth angles, and pointing angles ranging from straight aft to 60 deg canted inboard. Slot blowing was investigated for several slot lengths and fuselage stations. The effect of blowing rate was tested for both of these pneumatic systems. The most effective configurations were then further tested with a variation of both sideslip angle and Reynolds number over a range of angles of attack from 0 to 60 deg. It was found that a very robust system can be developed that provides yawing moments at angles of attack up to 60 deg that significantly exceeds that available from 30 deg of rudder deflection (F/A-18 maximum) at 0 deg angle of attack.

  13. Effect of sequential pneumatic compression therapy on venous blood velocity, refilling time, pain and quality of life in women with varicose veins: a randomized control study

    PubMed Central

    Yamany, Abeer; Hamdy, Bassant

    2016-01-01

    [Purpose] The aim of this study was to investigate the effects of sequential pneumatic compression therapy on venous blood flow, refilling time, pain level, and quality of life in women with varicose veins. [Subjects and Methods] Twenty-eight females with varicose veins were selected and randomly allocated to a control group, and experimental group. Maximum and mean venous blood velocities, the refilling time, pain by visual analog scale and quality of life by Aberdeen Varicose Veins Questionnaire were measured in all patients before and after six weeks of treatment. Both groups received lower extremity exercises; in addition, patients in the experimental group received sequential pneumatic compression therapy for 30 minutes daily, five days a week for six weeks. [Results] All measured parameters improved significantly in both groups, comparison of post treatment measurements between groups showed that the maximum and mean blood flow velocity, the pain level, and quality of life were significantly higher in the experimental group compared with the control group. On the other hand there was no significant difference between groups for refilling time. [Conclusion] Sequential pneumatic compression therapy with the applied parameters was an effective modality for increasing venous blood flow, reducing pain, and improving quality of women life with varicose veins. PMID:27512247

  14. [Effect of pneumatic compression in connection with ergotherapeutic treatment of Colles' fracture. A clinical controlled trial].

    PubMed

    Svensson, B H; Frellsen, M B; Basse, P N; Bliddal, H; Caspers, J; Parby, K

    1993-02-15

    We followed forty women with functional deficits in the wrist and hand after sustaining a Colles' fracture. The women participated in occupational therapy three times a week for three weeks. At the initial evaluation, after three weeks, and at a three month evaluation, we measured the following: range of joint movement, grip strength, hand volume (oedema), pain and ADL. There was significant improvement in most of the parameters measured after three weeks of occupational therapy, with a less significant improvement from three weeks to three months. Seventeen of the forty women received twenty minutes of intermittent pneumatic compression before occupational therapy. These patients showed significant improvement in wrist extension, compared with the control group of twenty-three patients. Occupational therapy is recommended for patients showing a functional deficit after Colles' fracture. Intermittent pneumatic compression is recommended as a supplement to occupational therapy.

  15. Active Control of Forebody Vortices on a schematic Aircraft Model

    DTIC Science & Technology

    2001-06-01

    coeffi- The system comprised two miniature soleniod on/off cient (C, = 0.0013) was sufficient to reliably switch pneumatic valves to control the flow to...method and time-average rolling moment, pitching moment, and normal force. Nomenclature T duration a valve is open during the alternating blow- b wing...reasonably high reduced frequency of the valves , and the tubes that delivered the air to the (* =0.16). Having established that the forebody vor- nozzles

  16. Venous thromboembolism prophylaxis in gynecologic surgery: a systematic review.

    PubMed

    Rahn, David D; Mamik, Mamta M; Sanses, Tatiana V D; Matteson, Kristen A; Aschkenazi, Sarit O; Washington, Blair B; Steinberg, Adam C; Harvie, Heidi S; Lukban, James C; Uhlig, Katrin; Balk, Ethan M; Sung, Vivian W

    2011-11-01

    To comprehensively review and critically assess the available gynecologic surgery venous thromboembolism prophylaxis literature and provide clinical practice guidelines. MEDLINE and Cochrane databases from inception to July 2010. We included randomized controlled trials in gynecologic surgery populations. Interventions and comparators included graduated compression stockings, intermittent pneumatic compression, unfractionated heparin, and low molecular weight heparin; placebo and routine postoperative care were allowed as comparators. One thousand two hundred sixty-six articles were screened, and 14 randomized controlled trials (five benign gynecologic, nine gynecologic oncology) met eligibility criteria. In addition, nine prospective or retrospective studies with at least 150 women were identified and provided data on venous thromboembolism risk stratification, gynecologic laparoscopy, and urogynecologic populations. Two reviewers independently screened articles with discrepancies adjudicated by a third. Eligible randomized controlled trials were extracted for these characteristics: study, participant, surgery, intervention, comparator, and outcomes data, including venous thromboembolism incidence and bleeding complications. Studies were individually and collectively assessed for methodologic quality and strength of evidence. Overall incidence of clinical venous thromboembolism was 0-2% in the benign gynecologic population. With use of intermittent pneumatic compression for benign major procedures, venous thromboembolism incidence was less than 1%. No venous thromboembolisms were identified in prospective studies of benign laparoscopic procedures. Overall quality of evidence in the benign gynecologic literature was poor. Gynecologic-oncology randomized controlled trials reported venous thromboembolism incidence (including "silent" venous thromboembolisms) of 0-14.8% with prophylaxis and up to 34.6% without prophylaxis. Fair quality of evidence supports that unfractionated heparin and intermittent pneumatic compression are both superior to placebo or no intervention but insufficient to determine whether heparins are superior to intermittent pneumatic compression for venous thromboembolism prevention. Combining two of three risks (aged 60 years or older, cancer, or personal venous thromboembolism history) substantially elevated the risk of venous thromboembolism. Intermittent pneumatic compression provides sufficient prophylaxis for the majority of gynecology patients undergoing benign surgery. Additional risk factors warrant the use of combined mechanical and pharmacologic prophylaxis.

  17. Cultivation of mammalian cells using a single-use pneumatic bioreactor system.

    PubMed

    Obom, Kristina M; Cummings, Patrick J; Ciafardoni, Janelle A; Hashimura, Yasunori; Giroux, Daniel

    2014-10-10

    Recent advances in mammalian, insect, and stem cell cultivation and scale-up have created tremendous opportunities for new therapeutics and personalized medicine innovations. However, translating these advances into therapeutic applications will require in vitro systems that allow for robust, flexible, and cost effective bioreactor systems. There are several bioreactor systems currently utilized in research and commercial settings; however, many of these systems are not optimal for establishing, expanding, and monitoring the growth of different cell types. The culture parameters most challenging to control in these systems include, minimizing hydrodynamic shear, preventing nutrient gradient formation, establishing uniform culture medium aeration, preventing microbial contamination, and monitoring and adjusting culture conditions in real-time. Using a pneumatic single-use bioreactor system, we demonstrate the assembly and operation of this novel bioreactor for mammalian cells grown on micro-carriers. This bioreactor system eliminates many of the challenges associated with currently available systems by minimizing hydrodynamic shear and nutrient gradient formation, and allowing for uniform culture medium aeration. Moreover, the bioreactor's software allows for remote real-time monitoring and adjusting of the bioreactor run parameters. This bioreactor system also has tremendous potential for scale-up of adherent and suspension mammalian cells for production of a variety therapeutic proteins, monoclonal antibodies, stem cells, biosimilars, and vaccines.

  18. The pneumatic syringe: a simple apparatus for self-administration of drugs by rats.

    PubMed

    Weeks, J R

    1977-12-01

    Drug solution is delivered by a syringe operated by a pneumatic cylinder. Recommended delivery volumes are from 10 to 200 microliter. A solid-state control unit is described which can operate two syringes (drug injection and flush), has outputs for recording responses and injections, and can be programmed to provide several schedules of reinforcement. All components are readily commercially available.

  19. Free-flight investigation of forebody blowing for stability and control

    NASA Technical Reports Server (NTRS)

    Brandon, Jay M.; Simon, James M.; Owens, D. Bruce; Kiddy, Jason S.

    1996-01-01

    A free-flight wind-tunnel investigation was conducted on a generic fighter model with forebody pneumatic vortex control for high angle-of-attack directional control. This is believed to be the first flight demonstration of a forebody blowing concept integrated into a closed-loop flight control system for stability augmentation and control. The investigation showed that the static wind tunnel estimates of the yaw control available generally agreed with flight results. The control scheme for the blowing nozzles consisted of an on/off control with a deadband. Controlled flight was obtained for the model using forebody blowing for directional control to beyond 45 deg. angle of attack.

  20. Development of the prototype pneumatic transfer system for ITER neutron activation system.

    PubMed

    Cheon, M S; Seon, C R; Pak, S; Lee, H G; Bertalot, L

    2012-10-01

    The neutron activation system (NAS) measures neutron fluence at the first wall and the total neutron flux from the ITER plasma, providing evaluation of the fusion power for all operational phases. The pneumatic transfer system (PTS) is one of the key components of the NAS for the proper operation of the system, playing a role of transferring encapsulated samples between the capsule loading machine, irradiation stations, counting stations, and disposal bin. For the validation and the optimization of the design, a prototype of the PTS was developed and capsule transfer tests were performed with the developed system.

  1. [The possibilities of forensic medical assessment of the wounds caused by discharges of 9 millimeter air rifles (pre-charge pneumatics)].

    PubMed

    Makarov, I Iu; Raĭzberg, S A

    2012-01-01

    The data available from the forensic medical practice do not allow the comprehensive, objective, and reliable assessment of injuries to the human body and damages to the clothes inflicted by the shots from a 9 millimeter (.357) or higher-caliber pneumatic rifle equipped with the pre-charge pneumatic system. The use of bullets of specific structure and configuration for such weapons accounts for their marked influence on the morphological features and the extent of the resulting wounds. These peculiarities provide a basis for the objective differentiation between their injurious effects.

  2. Applying reliability analysis to design electric power systems for More-electric aircraft

    NASA Astrophysics Data System (ADS)

    Zhang, Baozhu

    The More-Electric Aircraft (MEA) is a type of aircraft that replaces conventional hydraulic and pneumatic systems with electrically powered components. These changes have significantly challenged the aircraft electric power system design. This thesis investigates how reliability analysis can be applied to automatically generate system topologies for the MEA electric power system. We first use a traditional method of reliability block diagrams to analyze the reliability level on different system topologies. We next propose a new methodology in which system topologies, constrained by a set reliability level, are automatically generated. The path-set method is used for analysis. Finally, we interface these sets of system topologies with control synthesis tools to automatically create correct-by-construction control logic for the electric power system.

  3. TECHNOLOGY EVALUATION REPORT: SITE PROGRAM DEMONSTRATION TEST - ACCUTECH PNEUMATIC FRACTURING EXTRACTION AND HOT GAS INJECTION, PHASE 1 - VOLUME I

    EPA Science Inventory

    The Pneumatic Fracturing Extraction (PFE) process developed by Accutech Remedial Systems, Inc. makes it possible to use vapor extraction to remove volatile organics at increased rates from a broader range of vadose zones. The low permeability of silts, clays, shales, etc. would o...

  4. Complex modeling of technological processes in pneumatic mixers for production of dry construction mixtures

    NASA Astrophysics Data System (ADS)

    Orekhova, T. N.; Nosov, O. A.; Prokopenko, V. S.; Kachaev, A. E.

    2018-03-01

    The improvement of the design of the pneumatic mixers aimed at the possibility of obtaining homogeneous disperse systems, while the resource and energy saving issues play an important role in the conditions of enterprises that use this type of equipment in their technological chain, is described in the article.

  5. The Shock and Vibration Bulletin. Part 2. Environmental Testing, Shock Testing, Shock Analysis

    DTIC Science & Technology

    1981-05-01

    held at the Holiday 17 Inn at the Embarcadero, San Diego, CA on October 21-23, 1980. The cop), Naval Ocean Systems Center, San Diego CA was the Host...Hellqvist, Kockuma AB, Malmo Sweden A 9OMPUTER-PONTROLLED MEASURING SYSTEM HAVING 128 ANALOG MEASURING CHANNELS *$1D FACILITIES 1POR NIGNALANALYSIS...SANDWICH STRUCTURES M. L Sonu, University of Daytom Research Institute, Dayton, OH PNEUMATIC VIBRATION CONTROL USING ACTIVE FORCE GENERATORS S. Banker and R

  6. The Technique for CFD-Simulation of Fuel Valve from Pneumatic-Hydraulic System of Liquid-Propellant Rocket Engine

    NASA Astrophysics Data System (ADS)

    Shabliy, L. S.; Malov, D. V.; Bratchinin, D. S.

    2018-01-01

    In the article the description of technique for simulation of valves for pneumatic-hydraulic system of liquid-propellant rocket engine (LPRE) is given. Technique is based on approach of computational hydrodynamics (Computational Fluid Dynamics - CFD). The simulation of a differential valve used in closed circuit LPRE supply pipes of fuel components is performed to show technique abilities. A schematic and operation algorithm of this valve type is described in detail. Also assumptions made in the construction of the geometric model of the hydraulic path of the valve are described in detail. The calculation procedure for determining valve hydraulic characteristics is given. Based on these calculations certain hydraulic characteristics of the valve are given. Some ways of usage of the described simulation technique for research the static and dynamic characteristics of the elements of the pneumatic-hydraulic system of LPRE are proposed.

  7. Pneumatic artificial muscle actuators for compliant robotic manipulators

    NASA Astrophysics Data System (ADS)

    Robinson, Ryan Michael

    Robotic systems are increasingly being utilized in applications that require interaction with humans. In order to enable safe physical human-robot interaction, light weight and compliant manipulation are desirable. These requirements are problematic for many conventional actuation systems, which are often heavy, and typically use high stiffness to achieve high performance, leading to large impact forces upon collision. However, pneumatic artificial muscles (PAMs) are actuators that can satisfy these safety requirements while offering power-to-weight ratios comparable to those of conventional actuators. PAMs are extremely lightweight actuators that produce force in response to pressurization. These muscles demonstrate natural compliance, but have a nonlinear force-contraction profile that complicates modeling and control. This body of research presents solutions to the challenges associated with the implementation of PAMs as actuators in robotic manipulators, particularly with regard to modeling, design, and control. An existing PAM force balance model was modified to incorporate elliptic end geometry and a hyper-elastic constitutive relationship, dramatically improving predictions of PAM behavior at high contraction. Utilizing this improved model, two proof-of-concept PAM-driven manipulators were designed and constructed; design features included parallel placement of actuators and a tendon-link joint design. Genetic algorithm search heuristics were employed to determine an optimal joint geometry; allowing a manipulator to achieve a desired torque profile while minimizing the required PAM pressure. Performance of the manipulators was evaluated in both simulation and experiment employing various linear and nonlinear control strategies. These included output feedback techniques, such as proportional-integral-derivative (PID) and fuzzy logic, a model-based control for computed torque, and more advanced controllers, such as sliding mode, adaptive sliding mode, and adaptive neural network control. Results demonstrated the benefits of an accurate model in model-based control, and the advantages of adaptive neural network control when a model is unavailable or variations in payload are expected. Lastly, a variable recruitment strategy was applied to a group of parallel muscles actuating a common joint. Increased manipulator efficiency was observed when fewer PAMs were activated, justifying the use of variable recruitment strategies. Overall, this research demonstrates the benefits of pneumatic artificial muscles as actuators in robotics applications. It demonstrates that PAM-based manipulators can be well-modeled and can achieve high tracking accuracy over a wide range of payloads and inputs while maintaining natural compliance.

  8. Soft pneumatic grippers embedded with stretchable electroadhesion

    NASA Astrophysics Data System (ADS)

    Guo, J.; Elgeneidy, K.; Xiang, C.; Lohse, N.; Justham, L.; Rossiter, J.

    2018-05-01

    Current soft pneumatic grippers cannot robustly grasp flat materials and flexible objects on curved surfaces without distorting them. Current electroadhesive grippers, on the other hand, are difficult to actively deform to complex shapes to pick up free-form surfaces or objects. An easy-to-implement PneuEA gripper is proposed by the integration of an electroadhesive gripper and a two-fingered soft pneumatic gripper. The electroadhesive gripper was fabricated by segmenting a soft conductive silicon sheet into a two-part electrode design and embedding it in a soft dielectric elastomer. The two-fingered soft pneumatic gripper was manufactured using a standard soft lithography approach. This novel integration has combined the benefits of both the electroadhesive and soft pneumatic grippers. As a result, the proposed PneuEA gripper was not only able to pick-and-place flat and flexible materials such as a porous cloth but also delicate objects such as a light bulb. By combining two soft touch sensors with the electroadhesive, an intelligent and shape-adaptive PneuEA material handling system has been developed. This work is expected to widen the applications of both soft gripper and electroadhesion technologies.

  9. Dynamic Measurement of Extra Long Stroke Cylinder in the Pneumatic System

    NASA Astrophysics Data System (ADS)

    Chang, Ho; Lan, Chou-wei; Chen, Liang-Chia

    2006-10-01

    This paper sets up the measure and control system of the dynamic characteristics of the extra long stroke cylinder. In the different types of the control conditions (e.g. different control law, operating pressure and direct control valves), using the measure and control system to measure the relation between the pressure and the velocity of the motion of the long stroke cylinder and to observe the stick slip phenomenon of the motion of the long stroke cylinder. In the innovate measurement system, two pressure sensors are set on the long stroke cylinder to measure the difference of the pressure between the inlet and the exhaust of the long stroke cylinder. In additions, a draw line encoder is set on the system to measure the position and the velocity of the motion of the long stroke cylinder. The measuring data of the measure system is transferred to the computer via A/D interface card and counter card, and Home-made program of Haptic Interface Device is used to control the system, saving the data of the motion of the long stroke cylinder. The system uses different types of direction control valve to control the motion of the long stroke cylinder and compares the difference of the motion of the long stroke cylinder. The results show that the motion of the cylinder that pauses in the middle of the cylinder stroke and causes the stick slip phenomenon is more violent than the stick slip phenomenon in other position. When the length of the pause time reaches the some range, the acceleration of the motion of the cylinder will be rised substantially. This paper not only focuses on the testing method of the dynamic characteristics of the motion of the long stroke cylinder, but also includes the analysis of the dynamic characteristics of the motion of the long stroke cylinder. It provides the data of the dynamic characteristics of the motion of the long stroke cylinder to improve and design the pneumatic system of the long stroke cylinder.

  10. Oxygen consumption of a pneumatically controlled ventilator in a field anesthesia machine.

    PubMed

    Szpisjak, Dale F; Javernick, Elizabeth N; Kyle, Richard R; Austin, Paul N

    2008-12-01

    Field anesthesia machines (FAM) have been developed for remote locations where reliable supplies of compressed medical gases or electricity may be absent. In place of electricity, pneumatically controlled ventilators use compressed gas to power timing circuitry and actuate valves. We sought to determine the total O(2) consumption and ventilator gas consumption (drive gas [DG] plus pneumatic control [PC] gas) of a FAM's pneumatically controlled ventilator in mechanical models of high (HC) and low (LC) total thoracic compliance. The amount of total O(2) consumed by the Magellan-2200 (Oceanic Medical Products, Atchison, KS) FAM with pneumatically controlled ventilator was calculated using the ideal gas law and the measured mass of O(2) consumed from E cylinders. DG to the bellows canister assembly was measured with the Wright Respirometer Mk 8 (Ferraris Respiratory Europe, Hertford, UK). PC gas consumption was calculated by subtracting DG and fresh gas flow (FGF) from the total O(2) consumed from the E cylinder. The delivered tidal volume (V(T)) was measured with a pneumotach (Hans Rudolph, KS City, MO). Three different V(T) were tested (500, 750, and 1000 mL) with two lung models (HC and LC) using the Vent Aid Training Test Lung (MI Instruments, Grand Rapids, MI). Respiratory variables included an I:E of 1:2, FGF of 1 L/min, and respiratory rate of 10 breaths/min. Total O(2) consumption was directly proportional to V(T) and inversely proportional to compliance. The smallest total O(2) consumption rate (including FGF) was 9.3 +/- 0.4 L/min in the HC-500 model and the largest was 15.9 +/- 0.5 L/min in the LC-1000 model (P < 0.001). The mean PC circuitry consumption was 3.9 +/- 0.24 L/min or 390 mL +/- 24 mL/breath. To prepare for loss of central DG supply, patient safety will be improved by estimating cylinder duration for low total thoracic compliance. Using data from the smaller compliance and greatest V(T) model (LC-1000), a full O(2) E cylinder would be depleted in <42 min, whereas a full H cylinder would last approximately 433 min.

  11. F/A-18 and F-16 forebody vortex control, static and rotary-balance results

    NASA Technical Reports Server (NTRS)

    Kramer, Brian; Smith, Brooke

    1994-01-01

    The results from research on forebody vortex control on both the F/A-18 and the F-16 aircraft will be shown. Several methods of forebody vortex control, including mechanical and pneumatic schemes, will be discussed. The wind tunnel data includes both static and rotary balance data for forebody vortex control. Time lags between activation or deactivation of the pneumatic control and when the aircraft experiences the resultant forces are also discussed. The static (non-rotating) forces and pressures are then compared to similar configurations tested in the NASA Langley and DTRC Wind Tunnel, the NASA Ames 80'x120' Wind Tunnel, and in flight on the High Angle of Attack Research Vehicle (HARV).

  12. Applying Energy Conservation Retrofits to Standard Army Buildings: Project Design and Initial Energy Data

    DTIC Science & Technology

    1988-07-01

    Window Area 33 24 New Exterior Doors of Dining Hall 34 25 New Window Panels of Dining Hall 34 I 26 New Pneumatic Reset Controllers of Dining Hall 35 27...of conditioned air that is exhausted from the building soace during hood operation. HW temperature reset A new heating system controller from Taylor...to be as high. The converse is true as outdoor temperatures get colder. Resetting the temperature of the heating hot water with changes in the outdoor

  13. New Bedford Harbor Superfund Project Acushnet River Estuary Engineering Feasibility Study of Dredging and Dredged Material Disposal Alternatives. Report 10. Evaluation of Dredging and Dredging Control Technologies

    DTIC Science & Technology

    1988-11-01

    position and pulled through the sediment. Different opening configurations can be used to suit the sediment being removed (Figure 8). 42. The AMTEC ...associated with the New Bedford Harbor site and the relatively large minimum working depth of the AMTEC pneumatic system, this type of dredging

  14. Buckling of Elastomeric Beams Enables Actuation of Soft Machines

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yang, Dian; Mosadegh, Bobak; Ainla, Alar

    2015-09-21

    Soft, pneumatic actuators that buckle when interior pressure is less than exterior provide a new mechanism of actuation. Upon application of negative pneumatic pressure, elastic beam elements in these actuators undergo reversible, cooperative collapse, and generate a rotational motion. These actuators are inexpensive to fabricate, lightweight, easy to control, and safe to operate. They can be used in devices that manipulate objects, locomote, or interact cooperatively with humans.

  15. Wind tunnel investigation of a high lift system with pneumatic flow control

    NASA Astrophysics Data System (ADS)

    Victor, Pricop Mihai; Mircea, Boscoianu; Daniel-Eugeniu, Crunteanu

    2016-06-01

    Next generation passenger aircrafts require more efficient high lift systems under size and mass constraints, to achieve more fuel efficiency. This can be obtained in various ways: to improve/maintain aerodynamic performance while simplifying the mechanical design of the high lift system going to a single slotted flap, to maintain complexity and improve the aerodynamics even more, etc. Laminar wings have less efficient leading edge high lift systems if any, requiring more performance from the trailing edge flap. Pulsed blowing active flow control (AFC) in the gap of single element flap is investigated for a relatively large model. A wind tunnel model, test campaign and results and conclusion are presented.

  16. Aircraft Icing Handbook. Volume 2

    DTIC Science & Technology

    1991-03-01

    an airfoil surface. icenhobig - A surface property exhibiting a reduced adhesion to ice; literally, "ice-hating." light icing - The rate of...power, and are a light weight system of reasonable cost. K. ill I-I1 1.I.2 Pneumatic Impulse Ice Protection A Pneumatic Impulse Ice Protection System...should be about 5 to 6 seconds. During moderate icing a 60 second cycle is suggested, while for light icing, longer accretion times of 3 to 4 minutes

  17. 130. Photographic copy of drawing (undated, original drawing in Archives, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    130. Photographic copy of drawing (undated, original drawing in Archives, Public Affairs Department, Sears Merchandise Group, Hoffman Estates, Illinois). Engineer unknown. Full size. Pneumatic tube cartridges used at the time of the Plant closing. 4' PNEUMATIC TUBE SYSTEM - 11' LEATHER CARRIER - Sears Roebuck & Company Mail Order Plant, Merchandise Building, 924 South Homan Avenue, Chicago, Cook County, IL

  18. 131. Photographic copy of drawing (undated, original drawing in Archives, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    131. Photographic copy of drawing (undated, original drawing in Archives, Public Affairs Department, Sears Merchandise Group, Hoffman Estates, Illinois). Engineer unknown. Full size. Pneumatic tube cartridges used at the time of the Plant closing. 4' PNEUMATIC TUBE SYSTEM - 11' LEATHER CARRIER - Sears Roebuck & Company Mail Order Plant, Merchandise Building, 924 South Homan Avenue, Chicago, Cook County, IL

  19. Hydrodynamic injection with pneumatic valving for microchip electrophoresis with total analyte utilization

    PubMed Central

    Sun, Xuefei; Kelly, Ryan T.; Danielson, William F.; Agrawal, Nitin; Tang, Keqi; Smith, Richard D.

    2011-01-01

    A novel hydrodynamic injector that is directly controlled by a pneumatic valve has been developed for reproducible microchip capillary electrophoresis (CE) separations. The poly(dimethylsiloxane) (PDMS) devices used for evaluation comprise a separation channel, a side channel for sample introduction, and a pneumatic valve aligned at the intersection of the channels. A low pressure (≤ 3 psi) applied to the sample reservoir is sufficient to drive sample into the separation channel. The rapidly actuated pneumatic valve enables injection of discrete sample plugs as small as ~100 pL for CE separation. The injection volume can be easily controlled by adjusting the intersection geometry, the solution back pressure and the valve actuation time. Sample injection could be reliably operated at different frequencies (< 0.1 Hz to >2 Hz) with good reproducibility (peak height relative standard deviation ≤ 3.6%) and no sampling biases associated with the conventional electrokinetic injections. The separation channel was dynamically coated with a cationic polymer, and FITC-labeled amino acids were employed to evaluate the CE separation. Highly efficient (≥ 7.0 × 103 theoretical plates for the ~2.4 cm long channel) and reproducible CE separations were obtained. The demonstrated method has numerous advantages compared with the conventional techniques, including repeatable and unbiased injections, little sample waste, high duty cycle, controllable injected sample volume, and fewer electrodes with no need for voltage switching. The prospects of implementing this injection method for coupling multidimensional separations, for multiplexing CE separations and for sample-limited bioanalyses are discussed. PMID:21520147

  20. Assessment of Uinta Basin Oil and Natural Gas Well Pad ...

    EPA Pesticide Factsheets

    In the fall of 2016, a field study was conducted in the Uinta Basin Utah to improve information on oil and natural gas well pad pneumatic controllers (PCs) and emission measurement methods. A total of 80 PC systems at five oil sites (supporting six wells) and three gas sites (supporting 12 wells) were surveyed, and emissions data were produced using a combination of measurements and engineering emission estimates. Ninety-six percent of the PCs surveyed were the low actuation frequency intermittent vent type. The overall whole gas emission rate for the study was estimated at 0.37 scfh with the majority of emissions occurring from three continuous vent PCs (1.0 scfh average) and eleven (14%) malfunctioning intermittent vent PC systems (1.6 scfh average). Oil sites employed, on average 10.3 PC systems per well compared to 1.5 for gas sites. Oil and gas sites had group average PC emission rates of 0.28 scfh and 0.67 scfh, respectively, with this difference due in part to site selection procedures. The PC system types encountered, the engineering emissions estimate approach, and comparisons to measurements are described. Survey methods included identification of malfunctioning PC systems and emission measurements with augmented high volume sampling and installed mass flow meters, each providing a somewhat different picture of emissions that are elucidated through example cases. This paper reports on an oil and natural gas well pad pneumatic controller emissions stud

  1. Controllable surface haptics via particle jamming and pneumatics.

    PubMed

    Stanley, Andrew A; Okamura, Allison M

    2015-01-01

    The combination of particle jamming and pneumatics allows the simultaneous control of shape and mechanical properties in a tactile display. A hollow silicone membrane is molded into an array of thin cells, each filled with coffee grounds such that adjusting the vacuum level in any individual cell rapidly switches it between flexible and rigid states. The array clamps over a pressure-regulated air chamber with internal mechanisms designed to pin the nodes between cells at any given height. Various sequences of cell vacuuming, node pinning, and chamber pressurization allow the surface to balloon into a variety of shapes. Experiments were performed to expand existing physical models of jamming at the inter-particle level to define the rheological characteristics of jammed systems from a macroscopic perspective, relevant to force-displacement interactions that would be experienced by human users. Force-displacement data show that a jammed cell in compression fits a Maxwell model and a cell deflected in the center while supported only at the edges fits a Zener model, each with stiffness and damping parameters that increase at higher levels of applied vacuum. This provides framework to tune and control the mechanical properties of a jamming haptic interface.

  2. System Measures Pressures Aboard A Compressor Rotor

    NASA Technical Reports Server (NTRS)

    Freedman, Robert J.; Senyitko, Richard G.; Blumenthal, Philip Z.

    1994-01-01

    Rotating pressure-measuring instrumentation includes on-board calibration standard. Computer-controlled, multichannel instrumentation system acquires pressure measurements from sensors mounted in 1.52-m-diameter rotor of compressor. Includes 5 miniature, electronically scanned pressure (ESP) modules, each containing 48 piezoresistive pressure sensors, pneumatic calibration valve, and electronic circuits for addressing and amplifying output of each sensor. Modules mounted on centerline of rotor, on instrumentation tower located inside nose cone of rotor. Subsystem designed to convert analog signal to distinct frequency without significantly affecting accuracy.

  3. An innovative approach for modeling and simulation of an automated industrial robotic arm operated electro-pneumatically

    NASA Astrophysics Data System (ADS)

    Popa, L.; Popa, V.

    2017-08-01

    The article is focused on modeling an automated industrial robotic arm operated electro-pneumatically and to simulate the robotic arm operation. It is used the graphic language FBD (Function Block Diagram) to program the robotic arm on Zelio Logic automation. The innovative modeling and simulation procedures are considered specific problems regarding the development of a new type of technical products in the field of robotics. Thus, were identified new applications of a Programmable Logic Controller (PLC) as a specialized computer performing control functions with a variety of high levels of complexit.

  4. Pan Am gets big savings at no cost

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tanz, D.

    Pan American World Airways' contract with an energy management control systems distributor enabled the company's terminal and maintenance facilities at JFK airport in New York to shift from housekeeping to major savings without additional cost. Energy savings from a pneumatic control system were split almost equally between Pan Am and Thomas S. Brown Associates (TSBA) Inc., and further savings are expected from a planned computer-controlled system. A full-time energy manager, able to give top priority to energy-consumption problems, was considered crucial to the program's success. Early efforts in light-level reduction and equipment scheduling required extensive persuasion and policing, but successfulmore » energy savings allowed the manager to progress to the more-extensive plants with TSBA.« less

  5. The Controlled Cortical Impact Model of Experimental Brain Trauma: Overview, Research Applications, and Protocol

    PubMed Central

    Osier, Nicole; Dixon, C. Edward

    2017-01-01

    Controlled cortical impact (CCI) is a commonly used and highly regarded model of brain trauma that uses a pneumatically or electromagnetically controlled piston to induce reproducible and well-controlled injury. The CCI model was originally used in ferrets and it has since been scaled for use in many other species. This chapter will describe the historical development of the CCI model, compare and contrast the pneumatic and electromagnetic models, and summarize key short- and long-term consequences of TBI that have been gleaned using this model. In accordance with the recent efforts to promote high-quality evidence through the reporting of common data elements (CDEs), relevant study details—that should be reported in CCI studies—will be noted. PMID:27604719

  6. The Controlled Cortical Impact Model of Experimental Brain Trauma: Overview, Research Applications, and Protocol.

    PubMed

    Osier, Nicole; Dixon, C Edward

    2016-01-01

    Controlled cortical impact (CCI) is a commonly used and highly regarded model of brain trauma that uses a pneumatically or electromagnetically controlled piston to induce reproducible and well-controlled injury. The CCI model was originally used in ferrets and it has since been scaled for use in many other species. This chapter will describe the historical development of the CCI model, compare and contrast the pneumatic and electromagnetic models, and summarize key short- and long-term consequences of TBI that have been gleaned using this model. In accordance with the recent efforts to promote high-quality evidence through the reporting of common data elements (CDEs), relevant study details-that should be reported in CCI studies-will be noted.

  7. Feasibility and testing of lighweight, energy efficient, additive manufactured pneumatic control valve

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Love, Lonnie J.; Mell, Ellen

    2015-02-01

    AeroValve s innovative pneumatic valve technology recycles compressed air through the valve body with each cycle of the valve, and was reported to reduce compressed air requirements by an average of 25% 30%.This technology collaboration project between ORNL and Aerovalve confirms the energy efficiency of valve performance. Measuring air consumption per work completed, the AeroValve was as much as 85% better than the commercial Festo valve.

  8. Fractional order PID controller for improvement of PMSM speed control in aerospace applications

    NASA Astrophysics Data System (ADS)

    Saraji, Ali Motalebi; Ghanbari, Mahmood

    2014-12-01

    Because of the benefits reduced size, cost and maintenance, noise, CO2 emissions and increased control flexibility and precision, to meet these expectations, electrical equipment increasingly utilize in modern aircraft systems and aerospace industry rather than conventional mechanic, hydraulic, and pneumatic power systems. Electric motor drives are capable of converting electrical power to drive actuators, pumps, compressors, and other subsystems at variable speeds. In the past decades, permanent magnet synchronous motor (PMSM) and brushless dc (BLDC) motor were investigated for aerospace applications such as aircraft actuators. In this paper, the fractional-order PID controller is used in the design of speed loop of PMSM speed control system. Having more parameters for tuning fractional order PID controller lead to good performance ratio to integer order. This good performance is shown by comparison fractional order PID controller with the conventional PI and tuned PID controller by Genetic algorithm in MATLAB soft wear.

  9. Vertebral Pneumaticity in the Ornithomimosaur Archaeornithomimus (Dinosauria: Theropoda) Revealed by Computed Tomography Imaging and Reappraisal of Axial Pneumaticity in Ornithomimosauria

    PubMed Central

    Watanabe, Akinobu; Eugenia Leone Gold, Maria; Brusatte, Stephen L.; Benson, Roger B. J.; Choiniere, Jonah; Davidson, Amy; Norell, Mark A.

    2015-01-01

    Among extant vertebrates, pneumatization of postcranial bones is unique to birds, with few known exceptions in other groups. Through reduction in bone mass, this feature is thought to benefit flight capacity in modern birds, but its prevalence in non-avian dinosaurs of variable sizes has generated competing hypotheses on the initial adaptive significance of postcranial pneumaticity. To better understand the evolutionary history of postcranial pneumaticity, studies have surveyed its distribution among non-avian dinosaurs. Nevertheless, the degree of pneumaticity in the basal coelurosaurian group Ornithomimosauria remains poorly known, despite their potential to greatly enhance our understanding of the early evolution of pneumatic bones along the lineage leading to birds. Historically, the identification of postcranial pneumaticity in non-avian dinosaurs has been based on examination of external morphology, and few studies thus far have focused on the internal architecture of pneumatic structures inside the bones. Here, we describe the vertebral pneumaticity of the ornithomimosaur Archaeornithomimus with the aid of X-ray computed tomography (CT) imaging. Complementary examination of external and internal osteology reveals (1) highly pneumatized cervical vertebrae with an elaborate configuration of interconnected chambers within the neural arch and the centrum; (2) anterior dorsal vertebrae with pneumatic chambers inside the neural arch; (3) apneumatic sacral vertebrae; and (4) a subset of proximal caudal vertebrae with limited pneumatic invasion into the neural arch. Comparisons with other theropod dinosaurs suggest that ornithomimosaurs primitively exhibited a plesiomorphic theropod condition for axial pneumaticity that was extended among later taxa, such as Archaeornithomimus and large bodied Deinocheirus. This finding corroborates the notion that evolutionary increases in vertebral pneumaticity occurred in parallel among independent lineages of bird-line archosaurs. Beyond providing a comprehensive view of vertebral pneumaticity in a non-avian coelurosaur, this study demonstrates the utility and need of CT imaging for further clarifying the early evolutionary history of postcranial pneumaticity. PMID:26682888

  10. Performance of Regolith Feed Systems for Analog Field Tests of In-Situ Resource Utilization Oxygen Production Plants in Mauna Kea, Hawaii

    NASA Technical Reports Server (NTRS)

    Townsend, Ivan I.; Mueller, Robert P.; Mantovani, James G.; Zacny, Kris A.; Craft, Jack

    2010-01-01

    This paper focuses on practical aspects of mechanical auger and pneumatic regolith conveying system feeding In-Situ Resource Utilization Oxygen production plants. The subsystems of these feedstock delivery systems include an enclosed auger device, pneumatic venturi educator, jet-lift regolith transfer, innovative electro-cyclone gas-particle separation/filtration systems, and compressors capable of dealing with hot hydrogen and/or methane gas re-circulating in the system. Lessons learned from terrestrial laboratory, reduced gravity and field testing on Mauna Kea Volcano in Hawaii during NASA lunar analog field tests will be discussed and practical design tips will be presented.

  11. Air Purity in Diving from Submarines. 1. Review and Preliminary Analyses

    DTIC Science & Technology

    1987-12-01

    Nathaniel Howard for technical assistance, and Susan Cecire for editorial assistance. iv INTRODUCTION The need for divers to use compressed air from...pneumatic control systems) and emergency submarine functions, and submarine interior air is frequently compressed back into the bank which will cycle...breathe the interior air for long periods, so why the concern for divers? First, the processes of compression (by multi-stage oil lubricated

  12. Mine Hoist Operator Training System. Phase I Report.

    DTIC Science & Technology

    1978-11-01

    Bodies of Knowledge Function Control speed of conveyances Hold conveyances in position Structural Components Types of brakes : * Disc * Drum - Jaw...Parallel motion Components of each type * Disc / drum * Pads/shoes * Operating mechanisms Operating mediums for braking * Hydraulic/pneumatic * Manual...SHAFT GUIDES Wood El BRAKES Steel Rails El Drum : Wire Rope: Jaw El Full Lock El Parallel Motion El Half Lock El Disc El LEVELS DRIVE MOTORS Single El

  13. Pneumatically Modulated Liquid Delivery System for Nebulizers

    DTIC Science & Technology

    2011-12-02

    VII. Acknowledgements 18 APPENDIX A: Complete Parts List 19 APPENDIX B: Source code for the Arduino Uno microcontroller (CD) 23 1 I...implemented. The Arduino Uno is a well-established hobbyist microcontroller, focused on ease-of-use and teaching non-computer programmers about embedded...circuits. The Arduino Uno uses an Atmega328 microcontroller with thirteen digital TTL control lines, six 10-bit resolution 0-5 V analog inputs, TTL

  14. Air-filled postcranial bones in theropod dinosaurs: physiological implications and the 'reptile'-bird transition.

    PubMed

    Benson, Roger B J; Butler, Richard J; Carrano, Matthew T; O'Connor, Patrick M

    2012-02-01

    Pneumatic (air-filled) postcranial bones are unique to birds among extant tetrapods. Unambiguous skeletal correlates of postcranial pneumaticity first appeared in the Late Triassic (approximately 210 million years ago), when they evolved independently in several groups of bird-line archosaurs (ornithodirans). These include the theropod dinosaurs (of which birds are extant representatives), the pterosaurs, and sauropodomorph dinosaurs. Postulated functions of skeletal pneumatisation include weight reduction in large-bodied or flying taxa, and density reduction resulting in energetic savings during foraging and locomotion. However, the influence of these hypotheses on the early evolution of pneumaticity has not been studied in detail previously. We review recent work on the significance of pneumaticity for understanding the biology of extinct ornithodirans, and present detailed new data on the proportion of the skeleton that was pneumatised in 131 non-avian theropods and Archaeopteryx. This includes all taxa known from significant postcranial remains. Pneumaticity of the cervical and anterior dorsal vertebrae occurred early in theropod evolution. This 'common pattern' was conserved on the line leading to birds, and is likely present in Archaeopteryx. Increases in skeletal pneumaticity occurred independently in as many as 12 lineages, highlighting a remarkably high number of parallel acquisitions of a bird-like feature among non-avian theropods. Using a quantitative comparative framework, we show that evolutionary increases in skeletal pneumaticity are significantly concentrated in lineages with large body size, suggesting that mass reduction in response to gravitational constraints at large body sizes influenced the early evolution of pneumaticity. However, the body size threshold for extensive pneumatisation is lower in theropod lineages more closely related to birds (maniraptorans). Thus, relaxation of the relationship between body size and pneumatisation preceded the origin of birds and cannot be explained as an adaptation for flight. We hypothesise that skeletal density modulation in small, non-volant, maniraptorans resulted in energetic savings as part of a multi-system response to increased metabolic demands. Acquisition of extensive postcranial pneumaticity in small-bodied maniraptorans may indicate avian-like high-performance endothermy. © 2011 The Authors. Biological Reviews © 2011 Cambridge Philosophical Society.

  15. Development of gait training system powered by pneumatic actuator like human musculoskeletal system.

    PubMed

    Yamamoto, Shin-ichiroh; Shibata, Yoshiyuki; Imai, Shingo; Nobutomo, Tatsuya; Miyoshi, Tasuku

    2011-01-01

    The purpose of this study was to develop a body weight support gait training system for stroke and spinal cord injury (SCI) patient. This system consists of an orthosis powered by pneumatic McKibben actuators and a piece of equipment of body weight support. The attachment of powered orthosis can be fit to individual subjects with different body size. This powered orthosis is driven by pneumatic McKibben actuators arranged as a pair of agonistic and antagonistic bi-articular muscle models and two pairs of agonistic and antagonistic mono-articular muscle models like the human musculoskeletal system. The body weight support equipment suspends the subject's body in a wire harness, with the body weight is supported continuously by a counterweight. The powered orthosis is attached to the body weight support equipment by a parallel linkage, and its movement of powered orthosis is limited at the sagittal plane. The weight of the powered orthosis is compensated by a parallel linkage with a gas-spring. In this paper, we report the detailed mechanics of this body weight support gait training system and the results of several experiments for evaluating the system. © 2011 IEEE

  16. Optimizing pneumatic conveying of biomass materials

    NASA Astrophysics Data System (ADS)

    DiCianni, Matthew Edward Michael

    2011-12-01

    Biomass is a readily available but underutilized energy resource. One of the main challenges is the inability of biomass feed stocks like corn stover or wood chips to flow freely without intermittent jamming. This research integrated an automated pneumatic conveying system to efficiently transport biomass into a biomass reactor. Material was held in a storage container until an end effector attached to a 3-axis controller engaged the material to flow through pneumatic vacuum in the carrier fluid of air. The material was disengaged from the carrier fluid through centripetal forces induced by a cyclone separator. As the air was pulled out of the cyclone, the biomass drops out the bottom due to gravitational forces and fell into a secondary storage hopper. The second storage container was for testing purposes only, where the actual apparatus would use a vertically oriented lock hopper to feed material into the biomass reactor. In the experimental test apparatus, sensors measured the storage hopper weight (mass-flow rate), pressure drop from the blower, and input power consumption of the motor. Parameters that were adjusted during testing include pipe diameter, material type, and motor speed. Testing indicated that decreasing the motor speed below its maximum still allows for conveyance of the material without blockage forming in the piping. The data shows that the power consumption of the system can be reduced based on the size and weight of the material introduced to the conveying pipe. Also, conveying certain materials proved to be problematic with particular duct diameters. Ultimately, an optimal duct diameter that can perform efficiently for a broad range of materials was chosen for the given system. Through these improvements, the energy return on investment will be improved for biomass feed stocks, which is taking a step in the right direction to secure the nation's energy independence.

  17. Optimization of valve opening process for the suppression of impulse exhaust noise

    NASA Astrophysics Data System (ADS)

    Li, Jingxiang; Zhao, Shengdun

    2017-02-01

    Impulse exhaust noise generated by the sudden impact of discharging flow of pneumatic systems has significant temporal characteristics including high sound pressure and rapid sound transient. The impulse noise exposures are more hazardous to hearing than the energy equivalent uniform noise exposures. This paper presents a novel approach to suppress the peak sound pressure as a major indicator of impulsiveness of the impulse exhaust noise by an optimization of the opening process of valve. Relationships between exhaust flow and impulse noise are described by thermodynamics and noise generating mechanism. Then an optimized approach by controlling the valve opening process is derived under a constraint of pre-setting exhaust time. A modified servo-direct-driven valve was designed and assembled in a typical pneumatic system for the verification experiments comparing with an original solenoid valve. Experimental results with groups of initial cylinder pressures and pre-setting exhaust times are shown to verify the effects of the proposed optimization. Some indicators of energy-equivalent and impulsiveness are introduced to discuss the effects of the noise suppressions. Relationship between noise reduction and exhaust time delay is also discussed.

  18. Freight pipelines: Current status and anticipated future use

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    1998-07-01

    This report is issued by the Task Committee on Freight Pipelines, Pipeline Division, ASCE. Freight pipelines of various types (including slurry pipeline, pneumatic pipeline, and capsule pipeline) have been used throughout the world for over a century for transporting solid and sometimes even package products. Recent advancements in pipeline technology, aided by advanced computer control systems and trenchless technologies, have greatly facilitated the transportation of solids by pipelines. Today, in many situations, freight pipelines are not only the most economical and practical means for transporting solids, they are also the most reliable, safest and most environmentally friendly transportation mode. Increasedmore » use of underground pipelines to transport freight is anticipated in the future, especially as the technology continues to improve and surface transportation modes such as highways become more congested. This paper describes the state of the art and expected future uses of various types of freight pipelines. Obstacles hindering the development and use of the most advanced freight pipeline systems, such as the pneumatic capsule pipeline for interstate transport of freight, are discussed.« less

  19. Pneumatic Regolith Transfer Systems for In-Situ Resource Utilization

    NASA Technical Reports Server (NTRS)

    Mueller, Robert P.; Townsend, Ivan I., III; Mantovani, James G.

    2010-01-01

    One aspect of In-Situ Resource Utilization (lSRU) in a lunar environment is to extract oxygen and other elements from the minerals that make up the lunar regolith. Typical ISRU oxygen production processes include but are not limited to hydrogen reduction, carbothermal and molten oxide electrolysis. All of these processes require the transfer of regolith from a supply hopper into a reactor for chemical reaction processing, and the subsequent extraction of the reacted regolith from the reactor. This paper will discuss recent activities in the NASA ISRU project involved with developing pneumatic conveying methods to achieve lunar regolith simulant transfer under I-g and 1/6-g gravitational environments. Examples will be given of hardware that has been developed and tested by NASA on reduced gravity flights. Lessons learned and details of pneumatic regolith transfer systems will be examined as well as the relative performance in a 1/6th G environment

  20. Hybrid Environmental Control System Integrated Modeling Trade Study Analysis for Commercial Aviation

    NASA Astrophysics Data System (ADS)

    Parrilla, Javier

    Current industry trends demonstrate aircraft electrification will be part of future platforms in order to achieve higher levels of efficiency in various vehicle level sub-systems. However electrification requires a substantial change in aircraft design that is not suitable for re-winged or re-engined applications as some aircraft manufacturers are opting for today. Thermal limits arise as engine cores progressively get smaller and hotter to improve overall engine efficiency, while legacy systems still demand a substantial amount of pneumatic, hydraulic and electric power extraction. The environmental control system (ECS) provides pressurization, ventilation and air conditioning in commercial aircraft, making it the main heat sink for all aircraft loads with exception of the engine. To mitigate the architecture thermal limits in an efficient manner, the form in which the ECS interacts with the engine will have to be enhanced as to reduce the overall energy consumed and achieve an energy optimized solution. This study examines a tradeoff analysis of an electric ECS by use of a fully integrated Numerical Propulsion Simulation System (NPSS) model that is capable of studying the interaction between the ECS and the engine cycle deck. It was found that a peak solution lays in a hybrid ECS where it utilizes the correct balance between a traditional pneumatic and a fully electric system. This intermediate architecture offers a substantial improvement in aircraft fuel consumptions due to a reduced amount of waste heat and customer bleed in exchange for partial electrification of the air-conditions pack which is a viable option for re-winged applications.

  1. On the Development of Fuel-Free Power Supply Sources on Pneumatic Energy Conversion Principles

    NASA Astrophysics Data System (ADS)

    Son, E. E.; Nikolaev, V. G.; Kudryashov, Yu. I.; Nikolaev, V. V.

    2017-12-01

    The article is devoted to the evaluation of capabilities and problems of creation of fuel-free power supply of isolated and autonomous Russian consumers of low (up to several hundreds kW) power based on the joint use of wind power plants and progressive systems of pneumatic accumulation and conversion of energy. The basic and functional schemes and component structure of the system prototype are developed and proposed, the evaluations of the expected technical and economic indicators of system are presented, and the ways of its further practical implementation are planned.

  2. Hydrodynamic injection with pneumatic valving for microchip electrophoresis with total analyte utilization

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sun, Xuefei; Kelly, Ryan T.; Danielson, William F.

    2011-04-26

    A novel hydrodynamic injector that is directly controlled by a pneumatic valve has been developed for reproducible microchip capillary electrophoresis (CE) separations. The poly(dimethylsiloxane) (PDMS) devices used for evaluation comprise a separation channel, a side channel for sample introduction, and a pneumatic valve aligned at the intersection of the channels. A low pressure (≤ 3 psi) applied to the sample reservoir is sufficient to drive sample into the separation channel. The rapidly actuated pneumatic valve enables injection of discrete sample plugs as small as ~100 pL for CE separation. The injection volume can be easily controlled by adjusting the intersectionmore » geometry, the solution back pressure and the valve actuation time. Sample injection could be reliably operated at different frequencies (< 0.1 Hz to >2 Hz) with good reproducibility (peak height relative standard deviation ≤ 3.6%) and no sampling biases associated with the conventional electrokinetic injections. The separation channel was dynamically coated with a cationic polymer, and FITC-labeled amino acids were employed to evaluate the CE separation. Highly efficient (≥ 7.0 × 103 theoretical plates for the ~2.4 cm long channel) and reproducible CE separations were obtained. The demonstrated method has numerous advantages compared with the conventional techniques, including repeatable and unbiased injections, no sample waste, high duty cycle, controllable injected sample volume, and fewer electrodes with no need for voltage switching. The prospects of implementing this injection method for coupling multidimensional separations, for multiplexing CE separations and for sample-limited bioanalyses are discussed.« less

  3. Braking System for Wind Turbines

    NASA Technical Reports Server (NTRS)

    Krysiak, J. E.; Webb, F. E.

    1987-01-01

    Operating turbine stopped smoothly by fail-safe mechanism. Windturbine braking systems improved by system consisting of two large steel-alloy disks mounted on high-speed shaft of gear box, and brakepad assembly mounted on bracket fastened to top of gear box. Lever arms (with brake pads) actuated by spring-powered, pneumatic cylinders connected to these arms. Springs give specific spring-loading constant and exert predetermined load onto brake pads through lever arms. Pneumatic cylinders actuated positively to compress springs and disengage brake pads from disks. During power failure, brakes automatically lock onto disks, producing highly reliable, fail-safe stops. System doubles as stopping brake and "parking" brake.

  4. Analysis of Poiseuille Flow Property in Two-Dimensional Mi-cro Channels of Microfluidic Pneumatic Micro-Valve

    NASA Astrophysics Data System (ADS)

    Yang, Shaohua; Long, Wei; Chen, Yajun

    2018-03-01

    In this paper, the control mechanism and mathematical description of the microfluidic flow in the microfluidic process of the PDMS membrane type pneumatic micro-valve were studied. The velocity and pressure variation law of the velocity field inside micro valve was analyzed by numerical simulation method. The influence of the two kinds of inlet drive modes on the working effect and the pressure flow characteristics of the pneumatic micro-valve was studied. The structure of the elastic solid valve diaphragm under the dual action of the airway and the liquid channel was analyzed. Deformation and stress distribution. The results show that the gas flow in the gas flow channel under the diaphragm by the vacuum part of the role of the formation of a suction gas vortex, pressure-driven mode was easier under the diaphragm to produce a strong gas vortex, resulting in internal and external pressure to promote diaphragm cut-off liquid channel; In the pressure pneumatic mode, the stress at both ends of the diaphragm was smaller, the membrane was not easy to tear failure.

  5. Pneumatic Microvalve-Based Hydrodynamic Sample Injection for High-Throughput, Quantitative Zone Electrophoresis in Capillaries

    PubMed Central

    2015-01-01

    A hybrid microchip/capillary electrophoresis (CE) system was developed to allow unbiased and lossless sample loading and high-throughput repeated injections. This new hybrid CE system consists of a poly(dimethylsiloxane) (PDMS) microchip sample injector featuring a pneumatic microvalve that separates a sample introduction channel from a short sample loading channel, and a fused-silica capillary separation column that connects seamlessly to the sample loading channel. The sample introduction channel is pressurized such that when the pneumatic microvalve opens briefly, a variable-volume sample plug is introduced into the loading channel. A high voltage for CE separation is continuously applied across the loading channel and the fused-silica capillary separation column. Analytes are rapidly separated in the fused-silica capillary, and following separation, high-sensitivity MS detection is accomplished via a sheathless CE/ESI-MS interface. The performance evaluation of the complete CE/ESI-MS platform demonstrated that reproducible sample injection with well controlled sample plug volumes could be achieved by using the PDMS microchip injector. The absence of band broadening from microchip to capillary indicated a minimum dead volume at the junction. The capabilities of the new CE/ESI-MS platform in performing high-throughput and quantitative sample analyses were demonstrated by the repeated sample injection without interrupting an ongoing separation and a linear dependence of the total analyte ion abundance on the sample plug volume using a mixture of peptide standards. The separation efficiency of the new platform was also evaluated systematically at different sample injection times, flow rates, and CE separation voltages. PMID:24865952

  6. Pneumatic Microvalve-Based Hydrodynamic Sample Injection for High-Throughput, Quantitative Zone Electrophoresis in Capillaries

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kelly, Ryan T.; Wang, Chenchen; Rausch, Sarah J.

    2014-07-01

    A hybrid microchip/capillary CE system was developed to allow unbiased and lossless sample loading and high throughput repeated injections. This new hybrid CE system consists of a polydimethylsiloxane (PDMS) microchip sample injector featuring a pneumatic microvalve that separates a sample introduction channel from a short sample loading channel and a fused silica capillary separation column that connects seamlessly to the sample loading channel. The sample introduction channel is pressurized such that when the pneumatic microvalve opens briefly, a variable-volume sample plug is introduced into the loading channel. A high voltage for CE separation is continuously applied across the loading channelmore » and the fused silica capillary separation column. Analytes are rapidly separated in the fused silica capillary with high resolution. High sensitivity MS detection after CE separation is accomplished via a sheathless CE/ESI-MS interface. The performance evaluation of the complete CE/ESI-MS platform demonstrated that reproducible sample injection with well controlled sample plug volumes could be achieved by using the PDMS microchip injector. The absence of band broadening from microchip to capillary indicated a minimum dead volume at the junction. The capabilities of the new CE/ESI-MS platform in performing high throughput and quantitative sample analyses were demonstrated by the repeated sample injection without interrupting an ongoing separation and a good linear dependence of the total analyte ion abundance on the sample plug volume using a mixture of peptide standards. The separation efficiency of the new platform was also evaluated systematically at different sample injection times, flow rates and CE separation voltages.« less

  7. Novel Design of a Soft Lightweight Pneumatic Continuum Robot Arm with Decoupled Variable Stiffness and Positioning.

    PubMed

    Giannaccini, Maria Elena; Xiang, Chaoqun; Atyabi, Adham; Theodoridis, Theo; Nefti-Meziani, Samia; Davis, Steve

    2018-02-01

    Soft robot arms possess unique capabilities when it comes to adaptability, flexibility, and dexterity. In addition, soft systems that are pneumatically actuated can claim high power-to-weight ratio. One of the main drawbacks of pneumatically actuated soft arms is that their stiffness cannot be varied independently from their end-effector position in space. The novel robot arm physical design presented in this article successfully decouples its end-effector positioning from its stiffness. An experimental characterization of this ability is coupled with a mathematical analysis. The arm combines the light weight, high payload to weight ratio and robustness of pneumatic actuation with the adaptability and versatility of variable stiffness. Light weight is a vital component of the inherent safety approach to physical human-robot interaction. To characterize the arm, a neural network analysis of the curvature of the arm for different input pressures is performed. The curvature-pressure relationship is also characterized experimentally.

  8. Novel Design of a Soft Lightweight Pneumatic Continuum Robot Arm with Decoupled Variable Stiffness and Positioning

    PubMed Central

    Xiang, Chaoqun; Atyabi, Adham; Theodoridis, Theo; Nefti-Meziani, Samia; Davis, Steve

    2018-01-01

    Abstract Soft robot arms possess unique capabilities when it comes to adaptability, flexibility, and dexterity. In addition, soft systems that are pneumatically actuated can claim high power-to-weight ratio. One of the main drawbacks of pneumatically actuated soft arms is that their stiffness cannot be varied independently from their end-effector position in space. The novel robot arm physical design presented in this article successfully decouples its end-effector positioning from its stiffness. An experimental characterization of this ability is coupled with a mathematical analysis. The arm combines the light weight, high payload to weight ratio and robustness of pneumatic actuation with the adaptability and versatility of variable stiffness. Light weight is a vital component of the inherent safety approach to physical human-robot interaction. To characterize the arm, a neural network analysis of the curvature of the arm for different input pressures is performed. The curvature-pressure relationship is also characterized experimentally. PMID:29412080

  9. Microfluidic valve with cored glass microneedle for microinjection.

    PubMed

    Lee, Sanghoon; Jeong, Wonje; Beebe, David J

    2003-08-01

    In this paper, a new microinjection device was constructed by fusing a glass microneedle and a PDMS-based microvalve. The microneedle was fabricated via traditional micropipette pulling. The PDMS-based microvalve regulates the fluid flow in the microchannel and microneedle. The 'ON/OFF' operation of the valve was controlled by manually supplied pneumatic pressure. The valve membrane utilized a two level geometry to improve control at low flow rates. The relation between pressure and flow was measured and the results showed that very small volumes of fluid (>1 nl) could be controlled. The valve operation was investigated by monitoring the tip of the needle and pneumatic pressure simultaneously and it demonstrated very stable 'ON/OFF' operation to the pressure change.

  10. Numerical investigation of influence on heat transfer characteristics to pneumatically conveyed dense phase flow by selecting models and boundary conditions

    NASA Astrophysics Data System (ADS)

    Zheng, Y.; Liu, Q.; Li, Y.

    2012-03-01

    Solids moving with a gas stream in a pipeline can be found in many industrial processes, such as power generation, chemical, pharmaceutical, food and commodity transfer processes. A mass flow rate of the solids is important characteristic that is often required to be measured (and controlled) to achieve efficient utilization of energy and raw materials in pneumatic conveying systems. The methods of measuring the mass flow rate of solids in a pneumatic pipeline can be divided into direct and indirect (inferential) measurements. A thermal solids' mass flow-meter, in principle, should ideally provide a direct measurement of solids flow rate, regardless of inhomogeneities in solids' distribution and environmental impacts. One key issue in developing a thermal solids' mass flow-meter is to characterize the heat transfer between the hot pipe wall and the gas-solids dense phase flow. The Eulerian continuum modeling with gas-solid two phases is the most common method for pneumatic transport. To model a gas-solid dense phase flow passing through a heated region, the gas phase is described as a continuous phase and the particles as the second phase. This study aims to describe the heat transfer characteristics between the hot wall and the gas-solids dense phase flow in pneumatic pipelines by modeling a turbulence gas-solid plug passing through the heated region which involves several actual and crucial issues: selections of interphase exchange coefficient, near-wall region functions and different wall surface temperatures. A sensitivity analysis was discussed to identify the influence on the heat transfer characteristics by selecting different interphase exchange coefficient models and different boundary conditions. Simulation results suggest that sensitivity analysis in the choice of models is very significant. The simulation results appear to show that a combination of choosing the Syamlal-O'Brien interphase exchange coefficient model and the standard k-ɛ model along with the standard wall function model might be the best approach, by which, the simulation data seems to be closest to the experimental results.

  11. Comparison of contractile and extensile pneumatic artificial muscles

    NASA Astrophysics Data System (ADS)

    Pillsbury, Thomas E.; Wereley, Norman M.; Guan, Qinghua

    2017-09-01

    Pneumatic artificial muscles (PAMs) are used in robotic and prosthetic applications due to their high power to weight ratio, controllable compliance, and simple design. Contractile PAMs are typically used in traditional hard robotics in place of heavy electric motors. As the field of soft robotics grows, extensile PAMs are beginning to have increased usage. This work experimentally tests, models, and compares contractile and extensile PAMs to demonstrate the advantages and disadvantages of each type of PAM and applications for which they are best suited.

  12. Grasping with a soft glove: intrinsic impedance control in pneumatic actuators

    PubMed Central

    2017-01-01

    The interaction of a robotic manipulator with unknown soft objects represents a significant challenge for traditional robotic platforms because of the difficulty in controlling the grasping force between a soft object and a stiff manipulator. Soft robotic actuators inspired by elephant trunks, octopus limbs and muscular hydrostats are suggestive of ways to overcome this fundamental difficulty. In particular, the large intrinsic compliance of soft manipulators such as ‘pneu-nets’—pneumatically actuated elastomeric structures—makes them ideal for applications that require interactions with an uncertain mechanical and geometrical environment. Using a simple theoretical model, we show how the geometric and material nonlinearities inherent in the passive mechanical response of such devices can be used to grasp soft objects using force control, and stiff objects using position control, without any need for active sensing or feedback control. Our study is suggestive of a general principle for designing actuators with autonomous intrinsic impedance control. PMID:28250097

  13. "MRI Stealth" robot for prostate interventions.

    PubMed

    Stoianovici, Dan; Song, Danny; Petrisor, Doru; Ursu, Daniel; Mazilu, Dumitru; Muntener, Michael; Mutener, Michael; Schar, Michael; Patriciu, Alexandru

    2007-01-01

    The paper reports an important achievement in MRI instrumentation, a pneumatic, fully actuated robot located within the scanner alongside the patient and operating under remote control based on the images. Previous MRI robots commonly used piezoelectric actuation limiting their compatibility. Pneumatics is an ideal choice for MRI compatibility because it is decoupled from electromagnetism, but pneumatic actuators were hardly controllable. This achievement was possible due to a recent technology breakthrough, the invention of a new type of pneumatic motor, PneuStep 1, designed for the robot reported here with uncompromised MRI compatibility, high-precision, and medical safety. MrBot is one of the "MRI stealth" robots today (the second is described in this issue by Zangos et al.). Both of these systems are also multi-imager compatible, being able to operate with the imager of choice or cross-imaging modalities. For MRI compatibility the robot is exclusively constructed of nonmagnetic and dielectric materials such as plastics, ceramics, crystals, rubbers and is electricity free. Light-based encoding is used for feedback, so that all electric components are distally located outside the imager's room. MRI robots are modern, digital medical instruments in line with advanced imaging equipment and methods. These allow for accessing patients within closed bore scanners and performing interventions under direct (in scanner) imaging feedback. MRI robots could allow e.g. to biopsy small lesions imaged with cutting edge cancer imaging methods, or precisely deploy localized therapy at cancer foci. Our robot is the first to show the feasibility of fully automated in-scanner interventions. It is customized for the prostate and operates transperineally for needle interventions. It can accommodate various needle drivers for different percutaneous procedures such as biopsy, thermal ablations, or brachytherapy. The first needle driver is customized for fully automated low-dose radiation seed brachytherapy. This paper gives an introduction to the challenges of MRI robot compatibility and presents the solutions adopted in making the MrBot. Its multi-imager compatibility and other preclinical tests are included. The robot shows the technical feasibility of MRI-guided prostate interventions, yet its clinical utility is still to be determined.

  14. “MRI Stealth” robot for prostate interventions

    PubMed Central

    STOIANOVICI, DAN; SONG, DANNY; PETRISOR, DORU; URSU, DANIEL; MAZILU, DUMITRU; MUTENER, MICHAEL; SCHAR, MICHAEL; PATRICIU, ALEXANDRU

    2011-01-01

    The paper reports an important achievement in MRI instrumentation, a pneumatic, fully actuated robot located within the scanner alongside the patient and operating under remote control based on the images. Previous MRI robots commonly used piezoelectric actuation limiting their compatibility. Pneumatics is an ideal choice for MRI compatibility because it is decoupled from electromagnetism, but pneumatic actuators were hardly controllable. This achievement was possible due to a recent technology breakthrough, the invention of a new type of pneumatic motor, PneuStep (1), designed for the robot reported here with uncompromised MRI compatibility, high-precision, and medical safety. MrBot is one of the “MRI stealth” robots today (the second is described in this issue by Zangos et al.). Both of these systems are also multi-imager compatible, being able to operate with the imager of choice or cross-imaging modalities. For MRI compatibility the robot is exclusively constructed of nonmagnetic and dielectric materials such as plastics, ceramics, crystals, rubbers and is electricity free. Light-based encoding is used for feedback, so that all electric components are distally located outside the imager’s room. MRI robots are modern, digital medical instruments in line with advanced imaging equipment and methods. These allow for accessing patients within closed bore scanners and performing interventions under direct (in scanner) imaging feedback. MRI robots could allow e.g. to biopsy small lesions imaged with cutting edge cancer imaging methods, or precisely deploy localized therapy at cancer foci. Our robot is the first to show the feasibility of fully automated in-scanner interventions. It is customized for the prostate and operates transperineally for needle interventions. It can accommodate various needle drivers for different percutaneous procedures such as biopsy, thermal ablations, or brachytherapy. The first needle driver is customized for fully automated low-dose radiation seed brachytherapy. This paper gives an introduction to the challenges of MRI robot compatibility and presents the solutions adopted in making the MrBot. Its multi-imager compatibility and other preclinical tests are included. The robot shows the technical feasibility of MRI-guided prostate interventions, yet its clinical utility is still to be determined. PMID:17763098

  15. Design of a Pneumatic Tool for Manual Drilling Operations in Confined Spaces

    NASA Astrophysics Data System (ADS)

    Janicki, Benjamin

    This master's thesis describes the design process and testing results for a pneumatically actuated, manually-operated tool for confined space drilling operations. The purpose of this device is to back-drill pilot holes inside a commercial airplane wing. It is lightweight, and a "locator pin" enables the operator to align the drill over a pilot hole. A suction pad stabilizes the system, and an air motor and flexible drive shaft power the drill. Two testing procedures were performed to determine the practicality of this prototype. The first was the "offset drill test", which qualified the exit hole position error due to an initial position error relative to the original pilot hole. The results displayed a linear relationship, and it was determined that position errors of less than .060" would prevent the need for rework, with errors of up to .030" considered acceptable. For the second test, a series of holes were drilled with the pneumatic tool and analyzed for position error, diameter range, and cycle time. The position errors and hole diameter range were within the allowed tolerances. The average cycle time was 45 seconds, 73 percent of which was for drilling the hole, and 27 percent of which was for positioning the device. Recommended improvements are discussed in the conclusion, and include a more durable flexible drive shaft, a damper for drill feed control, and a more stable locator pin.

  16. Undulatory Swimming Performance and Body Stiffness Modulation in a Soft Robotic Fish-Inspired Physical Model.

    PubMed

    Jusufi, Ardian; Vogt, Daniel M; Wood, Robert J; Lauder, George V

    2017-09-01

    Undulatory motion of the body is the dominant mode of locomotion in fishes, and numerous studies of body kinematics and muscle activity patterns have provided insights into the mechanics of swimming. However, it has not been possible to investigate how key parameters such as the extent of bilateral muscle activation affect propulsive performance due to the inability to manipulate muscle activation in live, freely swimming fishes. In this article we extend previous work on passive flexible mechanical models of undulatory propulsion by using actively controlled pneumatic actuators attached to a flexible foil to gain insight into undulatory locomotion and mechanisms for body stiffness control. Two soft actuators were attached on each side of a flexible panel with stiffness comparable to that of a fish body. To study how bilateral contraction can be used to modify axial body stiffness during swimming, we ran a parameter sweep of actuator contraction phasing and frequency. Thrust production by the soft pneumatic actuators was tested at cyclic undulation frequencies ranging from 0.3 to 1.2 Hz in a recirculating flow tank at flow speeds up to 28 cm/s. Overall, this system generated more thrust at higher tail beat frequencies, with a plateau in thrust above 0.8 Hz. Self-propelled speed was found to be 0.8 foil lengths per second or ∼13 cm/s when actuated at 0.55 Hz. This active pneumatic model is capable of producing substantial trailing edge amplitudes with a maximum excursion equivalent to 1.4 foil lengths, and of generating considerable thrust. Altering the extent of bilateral co-contraction in a range from -22% to 17% of the cycle period showed that thrust was maximized with some amount of simultaneous left-right actuation of ∼3% to 6% of the cycle period. When the system is exposed to water flow, thrust was substantially reduced for conditions of greatest antagonistic overlap in left-right actuation, and also for the largest latencies introduced. This experimental platform provides a soft robotic testbed for studying aquatic propulsion with active control of undulatory kinematics.

  17. Gene delivery by direct injection (microinjection) using a controlled-flow system.

    PubMed

    Dean, David A

    2006-12-01

    INTRODUCTIONThis protocol describes a method for constant-flow microinjection using the Pneumatic PicoPump (World Precision Instruments). This type of system is very simple and can be assembled on a relatively low budget. In this method, a constant flow of sample is delivered from the tip of the pipette, and the amount of sample injected into the cell is determined by how long the pipette remains in the cell. A typical system is composed of a pressure regulator that can be adjusted for two pressures (back pressure and injection pressure), a capillary holder, and a coarse and fine micromanipulator.

  18. A Role of Base Plate Jerk Feedback Scheme for Suppression of the Self Vibration in a Pneumatic Positioning Stage

    NASA Astrophysics Data System (ADS)

    Wali, Mohebullah; Nakamura, Yukinori; Wakui, Shinji

    In this study, a positioning stage is considered, which is actuated by four pneumatic cylinders and vertically supported by four coil-type spring isolators. Previously, we realized the base plate jerk feedback (BPJFB) to be analogues to a Master-Slave system which can synchronize the motion of the stage as a Slave to the motion of the base plate as a Master. However, in the case of real positioning, the stage had slightly self oscillation with higher frequency due to the higher gains set to the outer feedback loop controller besides its oscillation due to the natural vibration of the base plate. The self oscillation of stage was misunderstood to be the natural vibration of base plate due to the reaction force. However, according to the experimental results, the BPJFB scheme was able to control both of the mentioned vibrations. Suppression of the self vibration of stage is an interesting phenomenon, which should be experimentally investigated. Therefore, the current study focuses on the suppression of the self vibration of stage by using the BPJFB scheme. The experimental results show that besides operating as a Master-Slave synchronizing system, the PBJFB scheme is able to increase the damping ratio and stiffness of stage against its self vibration. This newly recognized phenomenon contributes to further increase the proportional gain of the outer feedback loop controller. As a result, the positioning speed and stability can be improved.

  19. Empirical modeling of dynamic behaviors of pneumatic artificial muscle actuators.

    PubMed

    Wickramatunge, Kanchana Crishan; Leephakpreeda, Thananchai

    2013-11-01

    Pneumatic Artificial Muscle (PAM) actuators yield muscle-like mechanical actuation with high force to weight ratio, soft and flexible structure, and adaptable compliance for rehabilitation and prosthetic appliances to the disabled as well as humanoid robots or machines. The present study is to develop empirical models of the PAM actuators, that is, a PAM coupled with pneumatic control valves, in order to describe their dynamic behaviors for practical control design and usage. Empirical modeling is an efficient approach to computer-based modeling with observations of real behaviors. Different characteristics of dynamic behaviors of each PAM actuator are due not only to the structures of the PAM actuators themselves, but also to the variations of their material properties in manufacturing processes. To overcome the difficulties, the proposed empirical models are experimentally derived from real physical behaviors of the PAM actuators, which are being implemented. In case studies, the simulated results with good agreement to experimental results, show that the proposed methodology can be applied to describe the dynamic behaviors of the real PAM actuators. Copyright © 2013 ISA. Published by Elsevier Ltd. All rights reserved.

  20. High cleanliness globe valve with sine mechanism drive

    NASA Astrophysics Data System (ADS)

    Luo, Hu

    2018-06-01

    This paper gives a new type of quick-opening globe valve for life support pneumatic control system of the safety cabin at underground coal mine. The valve adopts the sine mechanism to transmit the rotating of the handle in the range of 90° to the reciprocating motion of the spool. The mechanism implements the quick-opening function of the valve through controlling the contact and separation between the O-ring and the end face of the valve. Since there is no relative sliding between the sealing interfaces, the valve solute uncontrollable disadvantage wear particles which produced by package ball valve, to ensure high cleanliness in flow path. Traditional transmission mechanism has a reinforcement effect and reduce handle open torque. By the finite element method, the relationship between the contact force and the compression of O-ring is analyzed to provide the boundary condition for the calculation of the rotational torque. Meanwhile the velocity field and pressure field along the flow path are simulated. The caliber size of the valve and the flow resistance coefficient are obtained. There is higher cleanliness, more reliable sealing, smaller handle open torque advantage compared with existing packing ball valve. The above work presents a new technical approach for the design of pneumatic control valve of the safety cabin.

  1. An electromagnetic microvalve for pneumatic control of microfluidic systems.

    PubMed

    Liu, Xuling; Li, Songjing

    2014-10-01

    An electromagnetic microvalve for pneumatic control of microfluidic devices has been designed, fabricated, and tested. The microvalve is composed of two parts: a miniature electromagnetic actuator and a valve body. The electromagnetic actuator consists mainly of a thin polydimethylsiloxane (PDMS)-based elastomer, which acts as the valve diaphragm. The diaphragm, used as a solid hydraulic medium, converts the large contact area of a valve core into a small contact area of valve head while maintaining a large stroking force. This microvalve remains closed because of a compressed mechanical spring force generated by the actuator. On the other hand, when a voltage is applied, the valve core moves up, relaxing the thin PDMS membrane, opening the microvalve. The fast open response (~17 ms) of the valve was achieved with a leak rate as low as 0.026 sccm at 200 KPa (N2) pressure. We tested the pertinent dynamic parameters such as flow rate in on/off mode, flow rate of duty cycles, and actuated frequencies in pulse width modulation (PWM) mode. Our method provides a simple, cheap, and small microvalve that avoids the bulky and expensive external pressure control solenoid manifold. This allows it to be easily integrated into portable and disposable devices. © 2014 Society for Laboratory Automation and Screening.

  2. A Preliminary Study on the Toxic Combustion Products Testing of Polymers Used in High-Pressure Oxygen Systems

    NASA Technical Reports Server (NTRS)

    Hshieh, Fu-Yu; Beeson, Harold D.

    2004-01-01

    One likely cause of polymer ignition in a high-pressure oxygen system is adiabatic-compression heating of polymers caused by pneumatic impact. Oxidative _ pyrolysis or combustion of polymers in a high-pressure oxygen system could generate toxic gases. This paper reports the preliminary results of toxic combustion product testing of selected polymers in a pneumatic-impact test system. Five polymers commonly used in high-pressure oxygen systems, Nylon 6/6, polychlorotrifluoroethylene (CTFE), polytetrafluoroethylene (PTFE), fluoroelastomer (Viton(TradeMark) A), and nitrile rubber (Buna N), were tested in a pneumatic-impact test system at 2500- or 3500-psia oxygen pressure. The polymers were ignited and burned, then combustion products were collected in a stainless-steel sample bottle and analyzed by GC/MS/IRD, GC/FID, and GC/Methanizer/FID. The results of adiabatic-compression tests show that combustion of hydrocarbon polymers, nitrogen-containing polymers, and halogenated polymers in high-pressure oxygen systems are relatively complete. Toxicity of the combustion product gas is presumably much lower than the combustion product gas generated from ambient-pressure oxygen (or air) environments. The NASA-Lewis equilibrium code was used to determine the composition of combustion product gas generated from a simulated, adiabatic-compression test of nine polymers. The results are presented and discussed.

  3. An electronic scanner of pressure for wind tunnel models

    NASA Technical Reports Server (NTRS)

    Kauffman, Ronald C.; Coe, Charles F.

    1986-01-01

    An electronic scanner of pressure (ESOP) has been developed by NASA Ames Research Center for installation in wind tunnel models. An ESOP system consists of up to 20 pressure modules (PMs), each with 48 pressure transducers and a heater, an analog-to-digital (A/D) converter module, a microprocessor, a data controller, a monitor unit, a control and processing unit, and a heater controller. The PMs and the A/D converter module are sized to be installed in the models tested in the Ames Aerodynamics Division wind tunnels. A unique feature of the pressure module is the lack of moving parts such as a pneumatic switch used in other systems for in situ calibrations. This paper describes the ESOP system and the results of the initial testing of the system. The initial results indicate the system meets the original design goal of 0.15 percent accuracy.

  4. Automatic sequential fluid handling with multilayer microfluidic sample isolated pumping

    PubMed Central

    Liu, Jixiao; Fu, Hai; Yang, Tianhang; Li, Songjing

    2015-01-01

    To sequentially handle fluids is of great significance in quantitative biology, analytical chemistry, and bioassays. However, the technological options are limited when building such microfluidic sequential processing systems, and one of the encountered challenges is the need for reliable, efficient, and mass-production available microfluidic pumping methods. Herein, we present a bubble-free and pumping-control unified liquid handling method that is compatible with large-scale manufacture, termed multilayer microfluidic sample isolated pumping (mμSIP). The core part of the mμSIP is the selective permeable membrane that isolates the fluidic layer from the pneumatic layer. The air diffusion from the fluidic channel network into the degassing pneumatic channel network leads to fluidic channel pressure variation, which further results in consistent bubble-free liquid pumping into the channels and the dead-end chambers. We characterize the mμSIP by comparing the fluidic actuation processes with different parameters and a flow rate range of 0.013 μl/s to 0.097 μl/s is observed in the experiments. As the proof of concept, we demonstrate an automatic sequential fluid handling system aiming at digital assays and immunoassays, which further proves the unified pumping-control and suggests that the mμSIP is suitable for functional microfluidic assays with minimal operations. We believe that the mμSIP technology and demonstrated automatic sequential fluid handling system would enrich the microfluidic toolbox and benefit further inventions. PMID:26487904

  5. High-resolution small field-of-view magnetic resonance image acquisition system using a small planar coil and a pneumatic manipulator in an open MRI scanner.

    PubMed

    Miki, Kohei; Masamune, Ken

    2015-10-01

    Low-field open magnetic resonance imaging (MRI) is frequently used for performing image-guided neurosurgical procedures. Intraoperative magnetic resonance (MR) images are useful for tracking brain shifts and verifying residual tumors. However, it is difficult to precisely determine the boundary of the brain tumors and normal brain tissues because the MR image resolution is low, especially when using a low-field open MRI scanner. To overcome this problem, a high-resolution MR image acquisition system was developed and tested. An MR-compatible manipulator with pneumatic actuators containing an MR signal receiver with a small radiofrequency (RF) coil was developed. The manipulator had five degrees of freedom for position and orientation control of the RF coil. An 8-mm planar RF coil with resistance and inductance of 2.04 [Formula: see text] and 1.00 [Formula: see text] was attached to the MR signal receiver at the distal end of the probe. MR images of phantom test devices were acquired using the MR signal receiver and normal head coil for signal-to-noise ratio (SNR) testing. The SNR of MR images acquired using the MR signal receiver was 8.0 times greater than that of MR images acquired using the normal head coil. The RF coil was moved by the manipulator, and local MR images of a phantom with a 2-mm grid were acquired using the MR signal receiver. A wide field-of-view MR image was generated from a montage of local MR images. A small field-of-view RF system with a pneumatic manipulator was integrated in a low-field MRI scanner to allow acquisition of both wide field-of-view and high-resolution MR images. This system is promising for image-guided neurosurgery as it may allow brain tumors to be observed more clearly and removed precisely.

  6. SU-E-J-12: An Image-Guided Soft Robotic Patient Positioning System for Maskless Head-And-Neck Cancer Radiotherapy: A Proof-Of-Concept Study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ogunmolu, O; Gans, N; Jiang, S

    Purpose: We propose a surface-image-guided soft robotic patient positioning system for maskless head-and-neck radiotherapy. The ultimate goal of this project is to utilize a soft robot to realize non-rigid patient positioning and real-time motion compensation. In this proof-of-concept study, we design a position-based visual servoing control system for an air-bladder-based soft robot and investigate its performance in controlling the flexion/extension cranial motion on a mannequin head phantom. Methods: The current system consists of Microsoft Kinect depth camera, an inflatable air bladder (IAB), pressured air source, pneumatic valve actuators, custom-built current regulators, and a National Instruments myRIO microcontroller. The performance ofmore » the designed system was evaluated on a mannequin head, with a ball joint fixed below its neck to simulate torso-induced head motion along flexion/extension direction. The IAB is placed beneath the mannequin head. The Kinect camera captures images of the mannequin head, extracts the face, and measures the position of the head relative to the camera. This distance is sent to the myRIO, which runs control algorithms and sends actuation commands to the valves, inflating and deflating the IAB to induce head motion. Results: For a step input, i.e. regulation of the head to a constant displacement, the maximum error was a 6% overshoot, which the system then reduces to 0% steady-state error. In this initial investigation, the settling time to reach the regulated position was approximately 8 seconds, with 2 seconds of delay between the command start of motion due to capacitance of the pneumatics, for a total of 10 seconds to regulate the error. Conclusion: The surface image-guided soft robotic patient positioning system can achieve accurate mannequin head flexion/extension motion. Given this promising initial Result, the extension of the current one-dimensional soft robot control to multiple IABs for non-rigid positioning control will be pursued.« less

  7. Design of pneumatic proportional flow valve type 5/3

    NASA Astrophysics Data System (ADS)

    Laski, P. A.; Pietrala, D. S.; Zwierzchowski, J.; Czarnogorski, K.

    2017-08-01

    In this paper the 5/3-way pneumatic, proportional flow valve was designed and made. Stepper linear actuator was used to move the spool. The valve is controlled by the controlled based on a AVR microcontroller. Virtual model of the valve was created in CAD. The real element was made based on a standard 5/3-way manually actuated valve with hand lever, which was dismounted and replaced by linear stepper motor. All the elements was mounted in a specially made housing. The controller consists of microcontroller Atmega16, integrated circuit L293D, display, two potentiometers, three LEDs and six buttons. Series of research was also conducted. Simulation research were performed using CFD by the Flow Simulation addition to SolidWorks. During the experiments the valve characteristics of flow and pressure was determined.

  8. United States Air Force Environmental Restoration Program. Guidance on Soil Vapor Extraction Optimization

    DTIC Science & Technology

    2001-06-01

    Pump Exposed Capillary Fringe SVE System Pneumatic/ Hydraulic Fracturing Points Increased Advective Flow draw\\svehandbk1.cdr aee p1 4/5/01 022/736300...propagate further from the extraction well, increasing the advective flow zone round the well. Pneumatic and hydraulic fracturing are the primary methods...enhancing existing fractures and increasing the secondary fracture network. Hydraulic fracturing involves the injection of water or slurry into the

  9. Intracorporeal pneumatic shock application for the treatment of chronic plantar fasciitis: a randomized, double blind prospective clinical trial.

    PubMed

    Dogramaci, Yunus; Kalaci, Aydiner; Emir, Anil; Yanat, Ahmet Nedim; Gökçe, Ahmet

    2010-04-01

    Plantar fasciitis (PF) is a common clinical condition that usually resolves with non-operative treatments. Extracorporeal shock wave therapy (ESWT) has been used in the treatment of chronic PF not responding to other conservative measures; however, ESWT devices are expensive and available for daily practice in only few centers (In developing countries). A pneumatic lithotripter is a cheap and readily available device which uses pneumatic shock application for the intracorporeal lithotripsy. The aim of this study was to investigate the clinical efficacy of intracorporeal pneumatic shock therapy (IPST) application for the treatment of chronic PF using a cheap and readily available pneumatic lithotripter. A randomized, double-blind, placebo-controlled study was conducted. A total of 50 patients with clinically and radiologically confirmed PF were randomly allocated to either an active- (treatment) (n = 25) or inactive (placebo) (n = 25) group. Under local anesthesia and posterior tibial nerve block, a rigid probe was directly introduced into the calcaneal spur under fluoroscopic control; a standard protocol of 1,000 shock was applied during a single session into the calcaneal spur. The main outcome measure was the patients' subjective assessment of pain by means of a Visual Analog Scale (VAS) and the Roles and Maudsley Score before the treatment and 6 months later. At the 6 months, the rate of successful outcomes (excellent + good results) in the treatment group (92%) were significantly higher comparing to the control group (24%) (P < 0.001). Heel pain measured 6 months after using the VAS were 2.04 +/- 1.67 in treatment group and 7.16 +/- 1.57 in control group as compared to 8.92 +/- 1.22 and 9.12 +/- 1.23 before the commencement of the treatment. No complications attributable to the procedure such as rupture of the planter fascia, hematoma, or infection were observed during the study. This pilot study showed that IPST is an effective and safe method of treatment of patients with chronic PF not responding to conservative measures. IPST application should be considered before surgical intervention when the extracorporeal shock devices are not available for daily practice. However, further evaluation of this novel treatment is necessary to understand the exact mechanism of action.

  10. Design of Aircraft (Selected Chapters),

    DTIC Science & Technology

    1986-09-22

    9 - compressed air motor of the drive of the reverser of the thrust of fan; 10 - flexible drive shaft; 11 - gearbox and jack; 12 - moving ring; 13...24 - cutoff and control valve; 25 - main line of pneumatic system; 26 - pneumo-starter; 27 - given by compressed air motor hydraulic pump; 28...kilometer; p - mass air density; p, - on the surface of sea; .A=p/p°- relative density of air ; R - radius of the Earth, a radius turn/bank and so forth; S

  11. Fractional order PID controller for improvement of PMSM speed control in aerospace applications

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Saraji, Ali Motalebi; Ghanbari, Mahmood

    Because of the benefits reduced size, cost and maintenance, noise, CO2 emissions and increased control flexibility and precision, to meet these expectations, electrical equipment increasingly utilize in modern aircraft systems and aerospace industry rather than conventional mechanic, hydraulic, and pneumatic power systems. Electric motor drives are capable of converting electrical power to drive actuators, pumps, compressors, and other subsystems at variable speeds. In the past decades, permanent magnet synchronous motor (PMSM) and brushless dc (BLDC) motor were investigated for aerospace applications such as aircraft actuators. In this paper, the fractional-order PID controller is used in the design of speed loopmore » of PMSM speed control system. Having more parameters for tuning fractional order PID controller lead to good performance ratio to integer order. This good performance is shown by comparison fractional order PID controller with the conventional PI and tuned PID controller by Genetic algorithm in MATLAB soft wear.« less

  12. 49 CFR 218.5 - Definitions.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... distinguishable blue flag or blue light by day and a blue light at night. When attached to the operating controls... the exclusive control of mechanical department personnel. Controlling locomotive means a locomotive arranged as having the only controls over all electrical, mechanical and pneumatic functions for one or...

  13. 49 CFR 218.5 - Definitions.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... distinguishable blue flag or blue light by day and a blue light at night. When attached to the operating controls... the exclusive control of mechanical department personnel. Controlling locomotive means a locomotive arranged as having the only controls over all electrical, mechanical and pneumatic functions for one or...

  14. 49 CFR 236.817 - Switch, electro-pneumatic.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 4 2013-10-01 2013-10-01 false Switch, electro-pneumatic. 236.817 Section 236.817 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION... Switch, electro-pneumatic. A switch operated by an electro-pneumatic switch-and-lock movement. ...

  15. 49 CFR 236.817 - Switch, electro-pneumatic.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 4 2012-10-01 2012-10-01 false Switch, electro-pneumatic. 236.817 Section 236.817 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION... Switch, electro-pneumatic. A switch operated by an electro-pneumatic switch-and-lock movement. ...

  16. 49 CFR 236.817 - Switch, electro-pneumatic.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Switch, electro-pneumatic. 236.817 Section 236.817 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION... Switch, electro-pneumatic. A switch operated by an electro-pneumatic switch-and-lock movement. ...

  17. 49 CFR 236.817 - Switch, electro-pneumatic.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 4 2011-10-01 2011-10-01 false Switch, electro-pneumatic. 236.817 Section 236.817 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION... Switch, electro-pneumatic. A switch operated by an electro-pneumatic switch-and-lock movement. ...

  18. 49 CFR 236.817 - Switch, electro-pneumatic.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 4 2014-10-01 2014-10-01 false Switch, electro-pneumatic. 236.817 Section 236.817 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION... Switch, electro-pneumatic. A switch operated by an electro-pneumatic switch-and-lock movement. ...

  19. PNEUMATIC PUMP TEST FOR DESIGN OF SOIL VACUUM EXTRACTION

    EPA Science Inventory

    In-situ pneumatic pumping tests were performed to estimate the pneumatic permeability at a site containing soils contaminated with aviation gasoline. Determination of pneumatic permeability was necessary to evaluate soil-air discharge or pore volume exchange rates. Pressure propa...

  20. Development of a Stereo Vision Measurement System for a 3D Three-Axial Pneumatic Parallel Mechanism Robot Arm

    PubMed Central

    Chiang, Mao-Hsiung; Lin, Hao-Ting; Hou, Chien-Lun

    2011-01-01

    In this paper, a stereo vision 3D position measurement system for a three-axial pneumatic parallel mechanism robot arm is presented. The stereo vision 3D position measurement system aims to measure the 3D trajectories of the end-effector of the robot arm. To track the end-effector of the robot arm, the circle detection algorithm is used to detect the desired target and the SAD algorithm is used to track the moving target and to search the corresponding target location along the conjugate epipolar line in the stereo pair. After camera calibration, both intrinsic and extrinsic parameters of the stereo rig can be obtained, so images can be rectified according to the camera parameters. Thus, through the epipolar rectification, the stereo matching process is reduced to a horizontal search along the conjugate epipolar line. Finally, 3D trajectories of the end-effector are computed by stereo triangulation. The experimental results show that the stereo vision 3D position measurement system proposed in this paper can successfully track and measure the fifth-order polynomial trajectory and sinusoidal trajectory of the end-effector of the three- axial pneumatic parallel mechanism robot arm. PMID:22319408

  1. An instrumented object for hand exercise and assessment using a pneumatic pressure sensor

    NASA Astrophysics Data System (ADS)

    Mohan, A.; Tharion, G.; Kumar, R. K.; Devasahayam, S. R.

    2018-05-01

    Measurement of grip force is important for both exercise training and assessment of the hand during physical rehabilitation. The standard method uses a grip dynamometer which measures the force between the fingers and opposing thumb. The primary limitation of the grip dynamometer is the restriction of measurement to cylindrical grasps. Any deformation of the hand due to muscular or skeletal disease makes the grip dynamometer difficult or impossible to use. An alternative to the grip dynamometer is a sealed pneumatic object that can be gripped by the hand. Measurement of the internal pressure in the object can be related to the grip force. In this paper, we analyze such a pneumatic pressure sensing object for hand grip assessment and also describe an easy fabrication of the grip sensor. The instrumented object presented in this paper is designed to assess both the maximal voluntary grip forces and continuous grip force to monitor control of hand function during exercise under instruction from a therapist. Potential uses of such a pneumatic pressure sensing object for hand grip are in physical rehabilitation of patients following paralysing illnesses like stroke and spinal cord injury.

  2. Thromboprophylaxis using combined intermittent pneumatic compression and pharmacologic prophylaxis versus pharmacologic prophylaxis alone in critically ill patients: study protocol for a randomized controlled trial.

    PubMed

    Arabi, Yaseen M; Alsolamy, Sami; Al-Dawood, Abdulaziz; Al-Omari, Awad; Al-Hameed, Fahad; Burns, Karen E A; Almaani, Mohammed; Lababidi, Hani; Al Bshabshe, Ali; Mehta, Sangeeta; Al-Aithan, Abdulsalam M; Mandourah, Yasser; Almekhlafi, Ghaleb; Finfer, Simon; Abdukahil, Sheryl Ann I; Afesh, Lara Y; Dbsawy, Maamoun; Sadat, Musharaf

    2016-08-03

    Venous thromboembolism (VTE) remains a common problem in critically ill patients. Pharmacologic prophylaxis is currently the standard of care based on high-level evidence from randomized controlled trials. However, limited evidence exists regarding the effectiveness of intermittent pneumatic compression (IPC) devices. The Pneumatic compREssion for preventing VENous Thromboembolism (PREVENT trial) aims to determine whether the adjunct use of IPC with pharmacologic prophylaxis compared to pharmacologic prophylaxis alone in critically ill patients reduces the risk of VTE. The PREVENT trial is a multicenter randomized controlled trial, which will recruit 2000 critically ill patients from over 20 hospitals in three countries. The primary outcome is the incidence of proximal lower extremity deep vein thrombosis (DVT) within 28 days after randomization. Radiologists interpreting the scans are blinded to intervention allocation, whereas the patients and caregivers are unblinded. The trial has 80 % power to detect a 3 % absolute risk reduction in proximal DVT from 7 to 4 %. The first patient was enrolled in July 2014. As of May 2015, a total of 650 patients have been enrolled from 13 centers in Saudi Arabia, Canada and Australia. The first interim analysis is anticipated in July 2016. We expect to complete recruitment by 2018. Clinicaltrials.gov: NCT02040103 (registered on 3 November 2013). Current controlled trials: ISRCTN44653506 (registered on 30 October 2013).

  3. Statistical analysis plan for the Pneumatic CompREssion for PreVENting Venous Thromboembolism (PREVENT) trial: a study protocol for a randomized controlled trial.

    PubMed

    Arabi, Yaseen; Al-Hameed, Fahad; Burns, Karen E A; Mehta, Sangeeta; Alsolamy, Sami; Almaani, Mohammed; Mandourah, Yasser; Almekhlafi, Ghaleb A; Al Bshabshe, Ali; Finfer, Simon; Alshahrani, Mohammed; Khalid, Imran; Mehta, Yatin; Gaur, Atul; Hawa, Hassan; Buscher, Hergen; Arshad, Zia; Lababidi, Hani; Al Aithan, Abdulsalam; Jose, Jesna; Abdukahil, Sheryl Ann I; Afesh, Lara Y; Dbsawy, Maamoun; Al-Dawood, Abdulaziz

    2018-03-15

    The Pneumatic CompREssion for Preventing VENous Thromboembolism (PREVENT) trial evaluates the effect of adjunctive intermittent pneumatic compression (IPC) with pharmacologic thromboprophylaxis compared to pharmacologic thromboprophylaxis alone on venous thromboembolism (VTE) in critically ill adults. In this multicenter randomized trial, critically ill patients receiving pharmacologic thromboprophylaxis will be randomized to an IPC or a no IPC (control) group. The primary outcome is "incident" proximal lower-extremity deep vein thrombosis (DVT) within 28 days after randomization. Radiologists interpreting the lower-extremity ultrasonography will be blinded to intervention allocation, whereas the patients and treating team will be unblinded. The trial has 80% power to detect a 3% absolute risk reduction in the rate of proximal DVT from 7% to 4%. Consistent with international guidelines, we have developed a detailed plan to guide the analysis of the PREVENT trial. This plan specifies the statistical methods for the evaluation of primary and secondary outcomes, and defines covariates for adjusted analyses a priori. Application of this statistical analysis plan to the PREVENT trial will facilitate unbiased analyses of clinical data. ClinicalTrials.gov , ID: NCT02040103 . Registered on 3 November 2013; Current controlled trials, ID: ISRCTN44653506 . Registered on 30 October 2013.

  4. Treatment of ureteric calculi--use of Holmium: YAG laser lithotripsy versus pneumatic lithoclast.

    PubMed

    Tipu, Salman Ahmed; Malik, Hammad Afzal; Mohhayuddin, Nazim; Sultan, Gauhar; Hussain, Manzoor; Hashmi, Altaf; Naqvi, Syed Ali Anwar; Rizvi, Syed Adibul Hasan

    2007-09-01

    To compare the efficacy of Holmium: YAG laser and pneumatic lithoclast in treating ureteric calculi. The study included total of 100 patients divided into two equal groups of laser lithotripsy (LL) and pneumatic lithoclast (PL). Study was conducted between September 2006 and February 2007. Inclusion criteria were patients with a ureteric stone of size 1-2 cm and negative urine culture. An x-ray KUB was mandatory. IVU and CT pyelogram were also done when required. Procedures were done under general anaesthesia after a single dose of pre-operative antibiotic. A 7.5 Fr semi rigid ureteroscope was used for ureteroscopy in all cases. Holmium: YAG laser with 365 microm wide probe was employed in laser group and frequency was set between 5 and 10 Hz at a power of 10 to 15 W. Swiss lithoclast with single or multiple fire technique was used accordingly in PL group. Postoperatively patients underwent radiography and helical CT as required at 4th week of follow up to asses stone clearance. The mean patient age in LL and PL group was 38 +/- 10 and 40 +/- 10 years respectively. The male to female ratio and stone size were similar between the groups. Stone migration up in pelvicalyceal system occurred in two patients of LL group while in eight patients of PL group. JJ Stent was placed in 5(10%) patients in laser group where as 13 (26%) patients required it in pneumatic lithoclast group. Stone free rate at 4 weeks was 92% in laser group as compared to 82% in pneumatic lithoclast group. Hospital stay was more than 24 hours in 2 patients of laser group as compared to 5 patients of pneumatic lithoclast group. Complication rate was 4% in LL group whereas it was 14% in PL group. Holmium: YAG laser lithotripsy is a superior technology compared to pneumatic lithoclast in terms of rate of stone clearance and complications, especially in upper ureteric stones.

  5. Apparatus, system, and method for providing fabric-elastomer composites as pneumatic actuators

    DOEpatents

    Martinez, Ramses V.; Whitesides, George M.

    2017-10-25

    Soft pneumatic actuators based on composites consisting of elastomers with embedded sheet or fiber structures (e.g., paper or fabric) that are flexible but not extensible are described. On pneumatic inflation, these actuators move anisotropically, based on the motions accessible by their composite structures. They are inexpensive, simple to fabricate, light in weight, and easy to actuate. This class of structure is versatile: the same principles of design lead to actuators that respond to pressurization with a wide range of motions (bending, extension, contraction, twisting, and others). Paper, when used to introduce anisotropy into elastomers, can be readily folded into three-dimensional structures following the principles of origami; these folded structures increase the stiffness and anisotropy of the elastomeric actuators, while keeping them light in weight.

  6. Strategie de commande pour un systeme hybride eolien diesel avec stockage d'air comprime =

    NASA Astrophysics Data System (ADS)

    Perron, Francois

    The electrical energy provisioning of isolated sites requires a steady supply of diesel fuel which represents a significant logistical and economic burden. The main objective of this project is to propose a control strategy for an air storage wind diesel hybrid system (SHEDAC) and to evaluate its fuel reduction potential for a given site. This research is conducted within a result validation context. It encompasses the combination of a wind speed and load modeling on an isolated village including a SHEDAC model and the results are tailored to this specific site. Because the pneumatic hybridation of an otherwise unmodified diesel engine is at the core of the suggested approach, a detailed thermodynamic model of the engine behavior as well as a comprehensive friction analysis of its components is presented. Simulation results show that the energy recovery from the pneumatic pathway of the motor is counter productive and an alternative configuration involving an air turbine is proposed. The study of this modified SHEDAC is performed with a specific focus on the efficiency of the compressed air recovery path in an effort to make it as general as possible. Fuel consumption reductions of 49% could be achieved with this system while the recovery efficiency was etaair = 0.5.

  7. Bioinspired Robotic Fingers Based on Pneumatic Actuator and 3D Printing of Smart Material.

    PubMed

    Yang, Yang; Chen, Yonghua; Li, Yingtian; Chen, Michael Z Q; Wei, Ying

    2017-06-01

    In this article, we have proposed a novel robotic finger design principle aimed to address two challenges in soft pneumatic grippers-the controllability of the stiffness and the controllability of the bending position. The proposed finger design is composed of a 3D printed multimaterial substrate and a soft pneumatic actuator. The substrate has four polylactic acid (PLA) segments interlocked with three shape memory polymer (SMP) joints, inspired by bones and joints in human fingers. By controlling the thermal energy of an SMP joint, the stiffness of the joints is modulated due to the dramatic change in SMP elastic modulus around its glass transition temperature (T g ). When SMP joints are heated above T g , they exhibit very small stiffness, allowing the finger to easily bend around the SMP joints if the attached soft actuator is actuated. When there is no force from the soft actuator, shape recovery stress in SMP contributes to the finger's shape restoration. Since each joint's rotation can be individually controlled, the position control of the finger is made possible. Experimental analysis has been conducted to show the finger's variable stiffness and the result is compared with the analytical values. It is found that the stiffness ratio can be 24.9 times for a joint at room temperature (20°C) and at an elevated temperature of 60°C when air pressure p of the soft actuator is turned off. Finally, a gripper composed of two fingers is fabricated for demonstration.

  8. Speed Sensorless Induction Motor Drives for Electrical Actuators: Schemes, Trends and Tradeoffs

    NASA Technical Reports Server (NTRS)

    Elbuluk, Malik E.; Kankam, M. David

    1997-01-01

    For a decade, induction motor drive-based electrical actuators have been under investigation as potential replacement for the conventional hydraulic and pneumatic actuators in aircraft. Advantages of electric actuator include lower weight and size, reduced maintenance and operating costs, improved safety due to the elimination of hazardous fluids and high pressure hydraulic and pneumatic actuators, and increased efficiency. Recently, the emphasis of research on induction motor drives has been on sensorless vector control which eliminates flux and speed sensors mounted on the motor. Also, the development of effective speed and flux estimators has allowed good rotor flux-oriented (RFO) performance at all speeds except those close to zero. Sensorless control has improved the motor performance, compared to the Volts/Hertz (or constant flux) controls. This report evaluates documented schemes for speed sensorless drives, and discusses the trends and tradeoffs involved in selecting a particular scheme. These schemes combine the attributes of the direct and indirect field-oriented control (FOC) or use model adaptive reference systems (MRAS) with a speed-dependent current model for flux estimation which tracks the voltage model-based flux estimator. Many factors are important in comparing the effectiveness of a speed sensorless scheme. Among them are the wide speed range capability, motor parameter insensitivity and noise reduction. Although a number of schemes have been proposed for solving the speed estimation, zero-speed FOC with robustness against parameter variations still remains an area of research for speed sensorless control.

  9. 49 CFR 571.117 - Standard No. 117; Retreaded pneumatic tires.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 6 2010-10-01 2010-10-01 false Standard No. 117; Retreaded pneumatic tires. 571... Federal Motor Vehicle Safety Standards § 571.117 Standard No. 117; Retreaded pneumatic tires. S1. Scope. This standard specifies performance, labeling, and certification requirements for retreaded pneumatic...

  10. Pneumatic Muscle Actuated Equipment for Continuous Passive Motion

    NASA Astrophysics Data System (ADS)

    Deaconescu, Tudor T.; Deaconescu, Andrea I.

    2009-10-01

    Applying continuous passive rehabilitation movements as part of the recovery programme of patients with post-traumatic disabilities of the bearing joints of the inferior limbs requires the development of new high performance equipment. This chapter discusses a study of the kinematics and performance of such a new, continuous passive motion based rehabilitation system actuated by pneumatic muscles. The utilized energy source is compressed air ensuring complete absorption of the end of stroke shocks, thus minimizing user discomfort.

  11. Global performance parameters for different pneumatic bioreactors operating with water and glycerol solution: experimental data and CFD simulation.

    PubMed

    Rodriguez, G Y; Valverde-Ramírez, M; Mendes, C E; Béttega, R; Badino, A C

    2015-11-01

    Global variables play a key role in evaluation of the performance of pneumatic bioreactors and provide criteria to assist in system selection and design. The purpose of this work was to use experimental data and computational fluid dynamics (CFD) simulations to determine the global performance parameters gas holdup ([Formula: see text]) and volumetric oxygen transfer coefficient (k L a), and conduct an analysis of liquid circulation velocity, for three different geometries of pneumatic bioreactors: bubble column, concentric-tube airlift, and split tube airlift. All the systems had 5 L working volumes and two Newtonian fluids of different viscosities were used in the experiments: distilled water and 10 cP glycerol solution. Considering the high oxygen demand in certain types of aerobic fermentations, the assays were carried out at high flow rates. In the present study, the performances of three pneumatic bioreactors with different geometries and operating with two different Newtonian fluids were compared. A new CFD modeling procedure was implemented, and the simulation results were compared with the experimental data. The findings indicated that the concentric-tube airlift design was the best choice in terms of both gas holdup and volumetric oxygen transfer coefficient. The CFD results for gas holdup were consistent with the experimental data, and indicated that k L a was strongly influenced by bubble diameter and shape.

  12. Design and realization of sort manipulator of crystal-angle sort machine

    NASA Astrophysics Data System (ADS)

    Wang, Ming-shun; Chen, Shu-ping; Guan, Shou-ping; Zhang, Yao-wei

    2005-12-01

    It is a current tendency of development in automation technology to replace manpower with manipulators in working places where dangerous, harmful, heavy or repetitive work is involved. The sort manipulator is installed in a crystal-angle sort machine to take the place of manpower, and engaged in unloading and sorting work. It is the outcome of combing together mechanism, electric transmission, and pneumatic element and micro-controller control. The step motor makes the sort manipulator operate precisely. The pneumatic elements make the sort manipulator be cleverer. Micro-controller's software bestows some simple artificial intelligence on the sort manipulator, so that it can precisely repeat its unloading and sorting work. The combination of manipulator's zero position and step motor counting control puts an end to accumulating error in long time operation. A sort manipulator's design in the practice engineering has been proved to be correct and reliable.

  13. A Comprehensive Study on Technologies of Tyre Monitoring Systems and Possible Energy Solutions

    PubMed Central

    Kubba, Ali E.; Jiang, Kyle

    2014-01-01

    This article presents an overview on the state of the art of Tyre Pressure Monitoring System related technologies. This includes examining the latest pressure sensing methods and comparing different types of pressure transducers, particularly their power consumption and measuring range. Having the aim of this research to investigate possible means to obtain a tyre condition monitoring system (TCMS) powered by energy harvesting, various approaches of energy harvesting techniques were evaluated to determine which approach is the most applicable for generating energy within the pneumatic tyre domain and under rolling tyre dynamic conditions. This article starts with an historical review of pneumatic tyre development and demonstrates the reasons and explains the need for using a tyre condition monitoring system. Following this, different tyre pressure measurement approaches are compared in order to determine what type of pressure sensor is best to consider in the research proposal plan. Then possible energy harvesting means inside land vehicle pneumatic tyres are reviewed. Following this, state of the art battery-less tyre pressure monitoring systems developed by individual researchers or by world leading tyre manufacturers are presented. Finally conclusions are drawn based on the reviewed documents cited in this article and a research proposal plan is presented. PMID:24922457

  14. Sample Handling in Extreme Environments

    NASA Technical Reports Server (NTRS)

    Avellar, Louisa; Badescu, Mircea; Sherrit, Stewart; Bar-Cohen, Yoseph

    2013-01-01

    Harsh environments, such as that on Venus, preclude the use of existing equipment for functions that involve interaction with the environment. The operating limitations of current high temperature electronics are well below the actual temperature and pressure found on Venus (460 deg C and 92 atm), so proposed lander configurations typically include a pressure vessel where the science instruments are kept at Earth-like temperature and pressure (25 deg C and 1 atm). The purpose of this project was to develop and demonstrate a method for sample transfer from an external drill to internal science instruments for a lander on Venus. The initial concepts were string and pneumatically driven systems; and the latter system was selected for its ability to deliver samples at very high speed. The pneumatic system was conceived to be driven by the pressure difference between the Venusian atmosphere and the inside of the lander. The pneumatic transfer of a small capsule was demonstrated, and velocity data was collected from the lab experiment. The sample transfer system was modeled using CAD software and prototyped using 3D printing. General structural and thermal analyses were performed to approximate the proposed system's mass and effects on the temperature and pressure inside of the lander. Additionally, a sampler breadboard for use on Titan was tested and functionality problems were resolved.

  15. Automatic inspection system for nuclear fuel pellets or rods

    DOEpatents

    Miller, Jr., William H.; Sease, John D.; Hamel, William R.; Bradley, Ronnie A.

    1978-01-01

    An automatic inspection system is provided for determining surface defects on cylindrical objects such as nuclear fuel pellets or rods. The active element of the system is a compound ring having a plurality of pneumatic jet units directed into a central bore. These jet units are connected to provide multiple circuits, each circuit being provided with a pressure sensor. The outputs of the sensors are fed to a comparator circuit whereby a signal is generated when the difference of pressure between pneumatic circuits, caused by a defect, exceeds a pre-set amount. This signal may be used to divert the piece being inspected into a "reject" storage bin or the like.

  16. Suspension system vibration analysis with regard to variable type ability to smooth road irregularities

    NASA Astrophysics Data System (ADS)

    Rykov, S. P.; Rykova, O. A.; Koval, V. S.; Makhno, D. E.; Fedotov, K. V.

    2018-03-01

    The paper aims to analyze vibrations of the dynamic system equivalent of the suspension system with regard to tyre ability to smooth road irregularities. The research is based on static dynamics for linear systems of automated control, methods of correlation, spectral and numerical analysis. Input of new data on the smoothing effect of the pneumatic tyre reflecting changes of a contact area between the wheel and road under vibrations of the suspension makes the system non-linear which requires using numerical analysis methods. Taking into account the variable smoothing ability of the tyre when calculating suspension vibrations, one can approximate calculation and experimental results and improve the constant smoothing ability of the tyre.

  17. 21 CFR 882.4370 - Pneumatic cranial drill motor.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Pneumatic cranial drill motor. 882.4370 Section... drill motor. (a) Identification. A pneumatic cranial drill motor is a pneumatically operated power source used with removable rotating surgical cutting tools or drill bits on a patient's skull. (b...

  18. 21 CFR 882.4370 - Pneumatic cranial drill motor.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Pneumatic cranial drill motor. 882.4370 Section... drill motor. (a) Identification. A pneumatic cranial drill motor is a pneumatically operated power source used with removable rotating surgical cutting tools or drill bits on a patient's skull. (b...

  19. 21 CFR 882.4370 - Pneumatic cranial drill motor.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Pneumatic cranial drill motor. 882.4370 Section... drill motor. (a) Identification. A pneumatic cranial drill motor is a pneumatically operated power source used with removable rotating surgical cutting tools or drill bits on a patient's skull. (b...

  20. Experimental Investigation on The Electromagnetic Clutch Water pump and Pneumatic Compressor for Improving the Efficiency of an Engine

    NASA Astrophysics Data System (ADS)

    Kumarasubramanian, R.; Xavier, Goldwin; Nishanthi, W. Mary; Rajasekar, R.

    2017-05-01

    Considering the fuel crises today many work and research were conducted to reduce the fuel consumption of the internal combustion engine. The fuel consumption of an internal combustion engine can be relatively reduced by use of the electromagnetic clutch water pump and pneumatic compressor. Normally in an engine, the water pump is driven by the crankshaft, with an aid of belt, for the circulation of the water for the cooling process. The circulation of coolant is resisted by the thermostat valve, while the temperature inside the coolant jacket of the engine is below 375K the thermostat is closed only above 375K it tends to open. But water pump run continuously even when thermostat is closed. In pneumatic braking system, pneumatic or air compressor purpose is to compress the air and stored into the storage tank for the brake operation. When the air pressure of the storage tanks gets increases above its storage capacity pressure is regulated by governor, by passing them to atmosphere. Such unnecessary work of this water pump and air compressor can be minimized by use of the electromagnetic clutch water pump and air compressor. The European Driving Cycle is used to evaluate the performance of this water pump and air compressor when used in an engine. The result shows that the fuel economy of the engine while using electromagnetic water pump and pneumatic compressor were improved by 8.0% compared with conventional types which already exist. The application of these electromagnetic water pump and pneumatic compressor are expected to contribute for the improvement of engine performance because of their effect in reduction of the rate of fuel consumption.

  1. Diaphragmless shock wave generators for industrial applications of shock waves

    NASA Astrophysics Data System (ADS)

    Hariharan, M. S.; Janardhanraj, S.; Saravanan, S.; Jagadeesh, G.

    2011-06-01

    The prime focus of this study is to design a 50 mm internal diameter diaphragmless shock tube that can be used in an industrial facility for repeated loading of shock waves. The instantaneous rise in pressure and temperature of a medium can be used in a variety of industrial applications. We designed, fabricated and tested three different shock wave generators of which one system employs a highly elastic rubber membrane and the other systems use a fast acting pneumatic valve instead of conventional metal diaphragms. The valve opening speed is obtained with the help of a high speed camera. For shock generation systems with a pneumatic cylinder, it ranges from 0.325 to 1.15 m/s while it is around 8.3 m/s for the rubber membrane. Experiments are conducted using the three diaphragmless systems and the results obtained are analyzed carefully to obtain a relation between the opening speed of the valve and the amount of gas that is actually utilized in the generation of the shock wave for each system. The rubber membrane is not suitable for industrial applications because it needs to be replaced regularly and cannot withstand high driver pressures. The maximum shock Mach number obtained using the new diaphragmless system that uses the pneumatic valve is 2.125 ± 0.2%. This system shows much promise for automation in an industrial environment.

  2. Fluidics comparison between dual pneumatic and spring return high-speed vitrectomy systems.

    PubMed

    Brant Fernandes, Rodrigo A; Diniz, Bruno; Falabella, Paulo; Ribeiro, Ramiro; Teixeira, Anderson G; Magalhães, Octaviano; Moraes, Nilva; Maia, Andre; Farah, Michel E; Maia, Mauricio; Humayun, Mark S

    2015-01-01

    To compare the water and vitreous flow rates and duty cycle (DC) between two ultrahigh-speed vitrectomy systems: pneumatic with spring return (SR) and dual pneumatic (DP) probes. The flow rate was calculated using a high-sampling precision balance that measured the mass of water and vitreous removed from a vial by a vitreous cutter. Frame-by-frame analysis of a high-speed video of the cutter was used to determine the DC. Three cutters of each gauge (20, 23, and 25 G) were tested with an SR and a DP system using the standard DC setting (biased open) at 0 (water only), 1,000, 2,000, 3,000, 4,000, and 5,000 cuts per minute (CPM) with aspiration levels of 100, 200, 300, 400, 500, and 600 mm Hg. The DC was slightly higher with the SR system using most parameters and gauges although without statistical significance. The water flow rate was somewhat higher with the SR system, except for 25 G with 4,000 and 5,000 CPM. The vitreous flow rate was similar using most parameters, with the SR system showing higher flows at lower cut rates (1,000-3,000 CPM). SR and DP systems produced similar water and vitreous flow rates. Additional studies in human eyes are necessary to confirm these findings. Copyright 2015, SLACK Incorporated.

  3. 77 FR 16919 - Airworthiness Directives; Bombardier, Inc. Airplanes

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-03-23

    ... door from opening. It was found that the existing airstair door pneumatic shut-off valve control logic... Control Logic Change] to prevent the above-mentioned failure conditions. You may obtain further... Off Valve Control Logic Change, in accordance with the Accomplishment Instructions of Bombardier...

  4. Design and Fabrication of a PDMS Microchip Based Immunoassay

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shao, Guocheng; Wang, Wanjun; Wang, Jun

    2010-07-01

    In this paper, we describe the design and fabrication process of a polydimethylsiloxane (PDMS) microchip for on-chip multiplex immunoassay application. The microchip consists of a PDMS microfluidic channel layer and a micro pneumatic valve control layer. By selectively pressurizing the pneumatic microvalves, immuno reagents were controlled to flow and react in certain fluidic channel sites. Cross contamination was prevented by tightly closed valves. Our design was proposed to utilize PDMS micro channel surface as the solid phase immunoassay substrate and simultaneously detect four targets antigens on chip. Experiment result shows that 20psi valve pressure is sufficient to tightly close amore » 200µm wide micro channel with flow rate up to 20µl/min.« less

  5. Adaptation of the cortical somatosensory evoked potential following pulsed pneumatic stimulation of the lower face in adults.

    PubMed

    Custead, Rebecca; Oh, Hyuntaek; Rosner, Austin Oder; Barlow, Steven

    2015-10-05

    Cortical adaptation to sustained sensory input is a pervasive form of short-term plasticity in neurological systems. Its role in sensory perception in health and disease, or predicting long-term plastic changes resulting from sensory training offers insight into the mechanisms of somatosensory and sensorimotor processing. A 4-channel electroencephalography (EEG) recording montage was placed bilaterally (C3-P3, C4-P4, F7-P3, F8-P4) to characterize the short-term effects of pulsed pneumatic orofacial stimulation on the cortical somatosensory evoked potential (cSEP) in twenty neurotypical adults (mean age=21±2.88 years). A servo-controlled pneumatic amplifier was used to deliver a repetitive series of pneumatic pulse trains (six 50-ms pulses, 5-second intertrain interval) through a linked pair of custom acetal homopolymer probes (aka TAC-Cells) adhered to the nonglabrous skin of the lower face proximal to the right oral angle to synchronously activate mechanoreceptive afferents in the trigeminal nerve. Blocks of pulse trains were counterbalanced among participants and delivered at two rates, 2 and 4Hz. TAC-Cell stimulation of the lower face consistently evoked a series of cSEPs at P7, N20, P28, N38, P75, N85, and P115. The spatial organization and adaptation of the evoked cSEP was dependent on stimulus pulse index (1-6 within the pulse train, p=.012), frequency of stimulus presentation (2 vs 4Hz, p<.001), component (P7-P115, p<.001), and recording montage (channels 1-4, p<.001). Early component latencies (P7-N20) were highly stable in polarity (sign) and latency, and consistent with putative far-field generators (e.g., trigeminal brainstem, ventroposteromedial thalamus). Copyright © 2015 Elsevier B.V. All rights reserved.

  6. Single-source mechanical loading system produces biaxial stresses in cylinders

    NASA Technical Reports Server (NTRS)

    Flower, J. F.; Stafford, R. L.

    1967-01-01

    Single-source mechanical loading system proportions axial-to-hoop tension loads applied to cylindrical specimens. The system consists of hydraulic, pneumatic, and lever arrangements which produce biaxial loading ratios.

  7. Drilling systems for extraterrestrial subsurface exploration.

    PubMed

    Zacny, K; Bar-Cohen, Y; Brennan, M; Briggs, G; Cooper, G; Davis, K; Dolgin, B; Glaser, D; Glass, B; Gorevan, S; Guerrero, J; McKay, C; Paulsen, G; Stanley, S; Stoker, C

    2008-06-01

    Drilling consists of 2 processes: breaking the formation with a bit and removing the drilled cuttings. In rotary drilling, rotational speed and weight on bit are used to control drilling, and the optimization of these parameters can markedly improve drilling performance. Although fluids are used for cuttings removal in terrestrial drilling, most planetary drilling systems conduct dry drilling with an auger. Chip removal via water-ice sublimation (when excavating water-ice-bound formations at pressure below the triple point of water) and pneumatic systems are also possible. Pneumatic systems use the gas or vaporization products of a high-density liquid brought from Earth, gas provided by an in situ compressor, or combustion products of a monopropellant. Drill bits can be divided into coring bits, which excavate an annular shaped hole, and full-faced bits. While cylindrical cores are generally superior as scientific samples, and coring drills have better performance characteristics, full-faced bits are simpler systems because the handling of a core requires a very complex robotic mechanism. The greatest constraints to extraterrestrial drilling are (1) the extreme environmental conditions, such as temperature, dust, and pressure; (2) the light-time communications delay, which necessitates highly autonomous systems; and (3) the mission and science constraints, such as mass and power budgets and the types of drilled samples needed for scientific analysis. A classification scheme based on drilling depth is proposed. Each of the 4 depth categories (surface drills, 1-meter class drills, 10-meter class drills, and deep drills) has distinct technological profiles and scientific ramifications.

  8. Application of pneumatic lift and control surface technology to advanced transport aircraft

    NASA Technical Reports Server (NTRS)

    Englar, Robert J.

    1996-01-01

    The application of pneumatic (blown) aerodynamic technology to both the lifting and the control surfaces of advanced transport aircraft can provide revolutionary changes in the performance and operation of these vehicles, ranging in speed regime from Advanced Subsonic Transports to the High Speed Civil Transport, and beyond. This technology, much of it based on the Circulation Control Wing blown concepts, can provide aerodynamic force augmentations of 80 to 100 (i.e., return of 80-100 pounds of force per pound of input momentum from the blowing jet). This can be achieved without use of external mechanical surfaces. Clever application of this technology can provide no-moving-part lifting surfaces (wings/tails) integrated into the control system to greatly simplify aircraft designs while improving their aerodynamic performance. Lift/drag ratio may be pneumatically tailored to fit the current phase of the flight, and takeoff/landing performance can be greatly improved by reducing ground roll distances and liftoff/touchdown speeds. Alternatively, great increases in liftoff weights and payloads are possible, as are great reductions in wing and tail planform size, resulting in optimized cruise wing designs. Furthermore, lift generation independent of angle of attack provides much promise for increased safety of flight in the severe updrafts/downdrafts of microbursts and windshears, which is further augmented by the ability to sustain flight at greatly reduced airspeeds. Load-tailored blown wings can also reduce tip vorticity during highlift operations and the resulting vortex wake hazards near terminal areas. Reduced noise may also be possible as these jets can be made to operate at low pressures. The planned presentation will support the above statements through discussions of recent experimental and numerical (CFD) research and development of these advanced blown aerodynamic surfaces, portions of which have been conducted for NASA. Also to be presented will be predicted performance of advanced transports resulting from these devices. Suggestions will be presented for additional innovative high-payoff research leading to further confirmation of these concepts and their application to advanced efficient commercial transport aircraft.

  9. Vacuum generation in pneumatic artificial heart drives with a specially designed ejector system.

    PubMed

    Schima, H; Huber, L; Spitaler, F

    1990-06-01

    To improve the filling characteristics of pneumatically driven membrane artificial hearts (AHs), a vacuum is applied during diastole. This paper describes an ejector system for AH-drivers based on the Venturi effect, which was designed for this purpose. It provides vacuums of more than -40 mmHg at flow rates up to 50 l/min requiring a supplying primary gas pressure of less than 150 kPa (1140 mmHg). Under normal working conditions, the necessary supply flow was less than 5l/min. The device is small, cheap, quiet and fail-safe, and has been evaluated successfully in experimental and clinical use.

  10. Pressure Regulators as Valves for Saving Compressed Air and their Influence on System Dynamics

    NASA Astrophysics Data System (ADS)

    Dvořák, Lukáš; Fojtášek, Kamil

    2015-05-01

    Pressure regulators in the field of pneumatic mechanisms can be used as valves for saving compressed air. For example it can be used to reduce the pressure when the piston rod is retracting unloaded and thus it is possible to save some energy. However the problem is that saving valve can significantly affect the dynamics of the pneumatic system. The lower pressure in the piston rod chamber causes extension of time for retraction of the piston rod. This article compare the air consumption experimentally determined and calculated, measured curves of pressure in cylinder chambers and piston speed when saving valve is set up differently.

  11. Portable Dextrous Force Feedback Master for robot telemanipulation (PDMFF)

    NASA Technical Reports Server (NTRS)

    Burdea, Grigore C.; Speeter, Thomas H.

    1989-01-01

    A major drawback of open loop masters is a lack of force feedback, limiting their ability to perform complex tasks such as assembly and repair. Researchers present a simple dextrous force feedback master for computer assisted telemanipulation. The device is compact, portable and can be held in the operator hand, without the need for a special joystick or console. The system is capable of both position feed forward and force feedback, using electronic position sensors and a pneumatic micro-actuator. The level of forces exercised by the pneumatic actuator is such that near rigidity may be attained. Experimental results showing good system linearity and small time lag are given.

  12. MarsVac: Pneumatic Sampling System for Planetary Exploration

    NASA Astrophysics Data System (ADS)

    Zacny, K.; Mungas, G.; Chu, P.; Craft, J.; Davis, K.

    2008-12-01

    We are proposing a Mars Sample Return scheme whereby a sample of regolith is acquired directly into a Mars Ascent Vehicle using a pneumatic system. Unlike prior developments that used suction to collect fines, the proposed system uses positive pressure to move the regolith. We envisage 3 pneumatic tubes to be embedded inside the 3 legs of the lander. Upon landing, the legs will burry themselves into the regolith and the tubes will fill up with regolith. With one puff of gas, the regolith can be lifted into a sampling chamber onboard of the Mars Ascent Vehicle. An additional chamber can be opened to acquire atmospheric gas and dust. The entire MSR will require 1) an actuator to open/close sampling chamber and 2) a valve to open gas cylinder. In the most recent study related to lunar excavation and funded under the NASA SBIR program we have shown that it is possible lift over 3000 grams of soil with only 1 gram of gas at 1atm. Tests conducted under Mars atmospheric pressure conditions (5 torr). In September of 2008, we will be performing tests at 1/6thg (Moon) and 1/3g (Mars) to determine mass lifting efficiencies in reduced gravities.

  13. MEMS scanner with 2D tilt, piston, and focus motion

    NASA Astrophysics Data System (ADS)

    Lani, S.; Bayat, D.; Petremand, Y.; Regamey, Y.-J.; Onillon, E.; Pierer, J.; Grossmann, S.

    2017-02-01

    A MEMS scanner with a high level of motion freedom has been developed. It includes a 2D mechanical tilting capability of +/- 15°, a piston motion of 50μm and a focus/defocus control system of a 2mm diameter mirror. The tilt and piston motion is achieved with an electromagnetic actuation (moving magnet) and the focus control with a deformation of the reflective surface with pneumatic actuation. This required the fabrication of at least one channel on the compliant membrane and a closed cavity below the mirror surface and connected to an external pressure regulator (vacuum to several bars). The fabrication relies on 3 SOI wafers, 2 for forming the compliant membranes and the integrated channel, and 1 to form the cavity mirror. All wafers were then assembled by fusion bonding. Pneumatic actuation for focus control can be achieved from front or back side; function of packaging concept. A reflective coating can be added at the mirror surface depending of the application. The tilt and piston actuation is achieved by electromagnetic actuation for which a magnet is fixed on the moving part of the MEMS device. Finally the MEMS device is mounted on a ceramic PCB, containing the actuation micro-coils. Concept, fabrication, and testing of the devices will be presented. A case study for application in an endoscope with an integrated high power laser and a MEMS steering mechanism will be presented.

  14. 21 CFR 110.40 - Equipment and utensils.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... HUMAN CONSUMPTION CURRENT GOOD MANUFACTURING PRACTICE IN MANUFACTURING, PACKING, OR HOLDING HUMAN FOOD... manufacturing systems, including gravimetric, pneumatic, closed, and automated systems, shall be of a design and...

  15. 21 CFR 110.40 - Equipment and utensils.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... HUMAN CONSUMPTION CURRENT GOOD MANUFACTURING PRACTICE IN MANUFACTURING, PACKING, OR HOLDING HUMAN FOOD... manufacturing systems, including gravimetric, pneumatic, closed, and automated systems, shall be of a design and...

  16. 21 CFR 110.40 - Equipment and utensils.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... HUMAN CONSUMPTION CURRENT GOOD MANUFACTURING PRACTICE IN MANUFACTURING, PACKING, OR HOLDING HUMAN FOOD... manufacturing systems, including gravimetric, pneumatic, closed, and automated systems, shall be of a design and...

  17. 21 CFR 110.40 - Equipment and utensils.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... HUMAN CONSUMPTION CURRENT GOOD MANUFACTURING PRACTICE IN MANUFACTURING, PACKING, OR HOLDING HUMAN FOOD... manufacturing systems, including gravimetric, pneumatic, closed, and automated systems, shall be of a design and...

  18. 21 CFR 110.40 - Equipment and utensils.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... HUMAN CONSUMPTION CURRENT GOOD MANUFACTURING PRACTICE IN MANUFACTURING, PACKING, OR HOLDING HUMAN FOOD... manufacturing systems, including gravimetric, pneumatic, closed, and automated systems, shall be of a design and...

  19. 46 CFR 54.10-15 - Pneumatic test (modifies UG-100).

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 2 2013-10-01 2013-10-01 false Pneumatic test (modifies UG-100). 54.10-15 Section 54.10-15 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING PRESSURE VESSELS Inspection, Reports, and Stamping § 54.10-15 Pneumatic test (modifies UG-100). (a) Pneumatic testing of welded pressure vessels shall be...

  20. 46 CFR 54.10-15 - Pneumatic test (modifies UG-100).

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 2 2012-10-01 2012-10-01 false Pneumatic test (modifies UG-100). 54.10-15 Section 54.10-15 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING PRESSURE VESSELS Inspection, Reports, and Stamping § 54.10-15 Pneumatic test (modifies UG-100). (a) Pneumatic testing of welded pressure vessels shall be...

  1. 46 CFR 54.10-15 - Pneumatic test (modifies UG-100).

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 2 2014-10-01 2014-10-01 false Pneumatic test (modifies UG-100). 54.10-15 Section 54.10-15 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING PRESSURE VESSELS Inspection, Reports, and Stamping § 54.10-15 Pneumatic test (modifies UG-100). (a) Pneumatic testing of welded pressure vessels shall be...

  2. Methods of and apparatus for levitating an eddy current probe

    DOEpatents

    Stone, William J.

    1988-05-03

    An eddy current probe is supported against the force of gravity with an air earing while being urged horizontally toward the specimen being examined by a spring and displaced horizontally against the force of the spring pneumatically. The pneumatic displacement is accomplished by flowing air between a plenum chamber fixed with respect to the probe and the surface of the specimen. In this way, the surface of the specimen can be examined without making mechanical contact therewith while precisely controlling the distance at which the probe stands-off from the surface of the specimen.

  3. Perceptual evaluation and acoustic analysis of pneumatic artificial larynx.

    PubMed

    Xu, Jie Jie; Chen, Xi; Lu, Mei Ping; Qiao, Ming Zhe

    2009-12-01

    To investigate the perceptual and acoustic characteristics of the pneumatic artificial larynx (PAL) and evaluate its speech ability and clinical value. Prospective study. The study was conducted in the Voice Lab, Department of Otorhinolaryngology, The First Affiliated Hospital of Nanjing Medical University. Forty-six laryngectomy patients using the PAL were rated for intelligibility and fluency of speech. The voice signals of sustained vowel /a/ for 40 healthy controls and 42 successful patients using the PAL were measured by a computer system. The acoustic parameters and sound spectrographs were analyzed and compared between the two groups. Forty-two of 46 patients using the PAL (91.3%) acquired successful speech capability. The intelligibility scores of 42 successful PAL speakers ranged from 71 to 95 percent, and the intelligibility range of four unsuccessful speakers was 30 to 50 percent. The fluency was judged as good or excellent in 42 successful patients, and poor or fair in four unsuccessful patients. There was no significant difference in average fundamental frequency, maximum intensity, jitter, shimmer, and normalized noise energy (NNE) between 42 successful PAL speakers and 40 healthy controls, while the maximum phonation time (MPT) of PAL speakers was slightly lower than that of the controls. The sound spectrographs of the patients using the PAL approximated those of the healthy controls. The PAL has the advantage of a high percentage of successful vocal rehabilitation. PAL speech is fluent and intelligible. The acoustic characteristics of the PAL are similar to those of a normal voice.

  4. The effect of pneumatic dilation in management of postfundoplication dysphagia.

    PubMed

    Sunjaya, D; Podboy, A; Blackmon, S H; Katzka, D; Halland, M

    2017-06-01

    Fundoplication surgery is a commonly performed procedure for gastro-esophageal reflux disease or hiatal hernia repair. Up to 10% of patients develop persistent postoperative dysphagia after surgery. Data on the effectiveness of pneumatic dilation for treatment are limited. The aim of this study was to evaluate clinical outcomes and identify clinical factors associated with successful response to pneumatic dilation among patients with persistent postfundoplication dysphagia (PPFD). We retrospectively evaluated patients who had undergone pneumatic dilation for PPFD between 1999 and 2016. Patients with dysphagia or achalasia prior to fundoplication were excluded. Demographic information, surgical history, severity of dysphagia, and clinical outcomes were collected. Data pertaining to esophagram, manometry, endoscopy, and pneumatic dilation were also collected. We identified 38 patients (82% female, 95% Caucasian, and median age 59 years) with PPFD who completed pneumatic dilation. The median postfundoplication dysphagia score was 2. Eleven patients had abnormal peristalsis on manometry. Seventeen patients reported response (seven complete) with an average decrease of 1 in their dysphagia score. Fifteen patients underwent reoperation due to PPFD. Hiatal hernia repair was the only factor that predicts a higher response rate to pneumatic dilation. Only one patient in our study developed complication (pneumoperitoneum) from pneumatic dilation. We found that pneumatic dilation to be a safe treatment option for PPFD with moderate efficacy. Patients who developed PPFD after a hiatal hernia repair may gain the greatest benefit after pneumatic dilation. We were not able to identify additional clinical, radiological, endoscopic, or manometric parameters that were predictive of response. © 2017 John Wiley & Sons Ltd.

  5. Comparison of measurement data at the impeller exit of a centrifugal compressor measured with both pneumatic and fast-response probes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Roduner, C.; Koeppel, P.; Kupferschmied, P.

    1999-07-01

    The main goal of these investigations was the refined measurement of unsteady high speed flow in a centrifugal compressor using the advanced FRAP{reg_sign} fast-response aerodynamic probe system. The present contribution focuses on the impeller exit region and shows critical comparisons between fast-response (time-resolving) and conventional pneumatic probe measurement results. Three probes of identical geometry (one fast and two pneumatic) were used to perform wall-to-wall traverses close to impeller exit. The data shown refer to a single running condition near the best point of the stage. The mass flow obtained from different probe measurements and from the standard orifice measurement weremore » compared. Stage work obtained from temperature rise measured with a FRAP{reg_sign} probe and from impeller outlet velocity vectors fields by using Euler`s turbine equation are presented. The comparison in terms of velocity magnitude and angle distribution is quite satisfactory, indicating the superior DC measurement capabilities of the fast-response probe system.« less

  6. Transfer orbit stage mechanisms thermal vacuum test

    NASA Technical Reports Server (NTRS)

    Oleary, Scott T.

    1990-01-01

    A systems level mechanisms test was conducted on the Orbital Sciences Corp.'s Transfer Orbit Stage (TOS). The TOS is a unique partially reusable transfer vehicle which will boost a satellite into its operational orbit from the Space Shuttle's cargo bay. The mechanical cradle and tilt assemblies will return to earth with the Space Shuttle while the Solid Rocket Motor (SRM) and avionics package are expended. A mechanisms test was performed on the forward cradle and aft tilting assemblies of the TOS under thermal vacuum conditions. Actuating these assemblies under a 1 g environment and thermal vacuum conditions proved to be a complex task. Pneumatic test fixturing was used to lift the forward cradle, and tilt the SRM, and avionics package. Clinometers, linear voltage displacement transducers, and load cells were used in the thermal vacuum chamber to measure the performance and characteristics of the TOS mechanism assembly. Incorporation of the instrumentation and pneumatic system into the test setup was not routine since pneumatic actuation of flight hardware had not been previously performed in the facility. The methods used are presented along with the problems experienced during the design, setup and test phases.

  7. Twin-Screw Extruder and Pellet Accelerator Integration Developments for ITER

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Meitner, Steven J; Baylor, Larry R; Combs, Stephen Kirk

    The ITER pellet injection system consisting of a twinscrew frozen hydrogen isotope extruder, coupled to a combination solenoid actuated pellet cutter and pneumatic pellet accelerator, is under development at the Oak Ridge National Laboratory. A prototype extruder has been built to produce a continuous solid deuterium extrusion and will be integrated with a secondary section, where pellets are cut, chambered, and launched with a single-stage pneumatic accelerator into the plasma through a guide tube. This integrated pellet injection system is designed to provide 5 mm fueling pellets, injected at a rate up to 10 Hz, or 3 mm edge localizedmore » mode (ELM) triggering pellets, injected at higher rates up to 20 Hz. The pellet cutter, chamber mechanism, and the solenoid operated pneumatic valve for the accelerator are optimized to provide pellet velocities between 200-300 m/s to ensure high pellet survivability while traversing the inner wall fueling guide tubes, and outer wall ELMpacing guide tubes. This paper outlines the current twin-screwextruder design, pellet accelerator design, and the integrationrequired for both fueling and ELM pacing pellets.« less

  8. The impact of circulation control on rotary aircraft controls systems

    NASA Technical Reports Server (NTRS)

    Kingloff, R. F.; Cooper, D. E.

    1987-01-01

    Application of circulation to rotary wing systems is a new development. Efforts to determine the near and far field flow patterns and to analytically predict those flow patterns have been underway for some years. Rotary wing applications present a new set of challenges in circulation control technology. Rotary wing sections must accommodate substantial Mach number, free stream dynamic pressure and section angle of attack variation at each flight condition within the design envelope. They must also be capable of short term circulation blowing modulation to produce control moments and vibration alleviation in addition to a lift augmentation function. Control system design must provide this primary control moment, vibration alleviation and lift augmentation function. To accomplish this, one must simultaneously control the compressed air source and its distribution. The control law algorithm must therefore address the compressor as the air source, the plenum as the air pressure storage and the pneumatic flow gates or valves that distribute and meter the stored pressure to the rotating blades. Also, mechanical collective blade pitch, rotor shaft angle of attack and engine power control must be maintained.

  9. Treatments for pediatric achalasia: Heller myotomy or pneumatic dilatation?

    PubMed

    Jung, C; Michaud, L; Mougenot, J-F; Lamblin, M-D; Philippe-Chomette, P; Cargill, G; Bonnevalle, M; Boige, N; Bellaïche, M; Viala, J; Hugot, J-P; Gottrand, F; Cezard, J-P

    2010-03-01

    The treatment of achalasia consists of reducing distal esophageal obstruction by either Heller myotomy surgery or endoscopic pneumatic dilatation. The aim of the present study was to evaluate the short- and middle-term results of these procedures in children. For technical reasons, children under six years old (n=8) were treated by surgery only, whereas patients over six years old (n=14) were treated by either Heller myotomy or pneumatic dilatation. Of the children aged under six years, 75% were symptom-free at six months and 83% at 24 months of follow-up. Of the patients aged over six years, complete remission was achieved by Heller myotomy in 44.5% vs. 55.5% by pneumatic dilatation after six months, and in 40% vs. 65%, respectively, after 24 months. Both pneumatic dilatation and Heller myotomy showed significant rates of failure. These results suggest that pneumatic dilatation may be considered a primary treatment in children over six years old. Also, where necessary, Heller myotomy and pneumatic dilatation may be used as complementary treatments.

  10. [Morphine self-administration by rats using a pneumatic syringe].

    PubMed

    Akiyama, Y; Takayama, S

    1988-06-01

    An apparatus for drug self-administration by rats using a pneumatic syringe was developed by Weeks. A microliter syringe operated by a pneumatic cylinder supplies an accurate volume of drug solution within one second. When coefficient of variation of infusion volume was compared among pneumatic syringe, infusion pump, and peristaltic pump, pneumatic syringe showed higher accuracy in infusion volume than the other two pumps. Since the infusion speed by a pneumatic syringe is very rapid (less than one second per infusion), the effect of infusion speed on reinforcing property of morphine was investigated. When rats self-administered 0.1, 0.3, 1.0, and 3.0 mg/kg/infusion of morphine by pneumatic syringes, the patterns of self-infusion were more stable, the number of self-infusions and the amount self-administered were larger, and a dose-response relationship was clearer in comparison with those self-infused the same doses of morphine for 5.6 seconds by infusion pumps or peristaltic pumps.

  11. Key issues in theoretical and functional pneumatic design

    NASA Astrophysics Data System (ADS)

    Xu, Z. G.; Yang, D. Y.; Liu, W. M.; Liu, T. T.

    2017-10-01

    This paper studies the energy release of the pneumatic engine in different thermodynamic processes, the isothermal process is the highest power output process, while adiabatic process is the lowest energy output process, and the energy release of the pneumatic engine is a multi-state thermodynamic process between them. Therefore heat exchanging should be increased between the pneumatic engine and the outer space, the gas expansion process in the cylinder should be as close as possible to the isothermal process. Heat exchange should be increased between the cylinder and the external spaces. Secondly, the fin structure is studied to increase the heat exchanging between the cylinder body and the outside space. The upper part has fin structures and the lower cylinder has no fin structure, this structure improved the working efficiency of pneumatic engine. Finally the cam and the hydraulic bottle of pneumatic engines are designed. Simulation and theoretical calculation are used to the analysis of the whole structure, which lay the foundation for the manufacturing and design of the pneumatic engines.

  12. Three Dimensional Solution of Pneumatic Active Control of Forebody Vortex Asymmetry

    NASA Technical Reports Server (NTRS)

    Kandil, Osama A.; SharafEl-Din, Hazem H.; Liu, C. H.

    1995-01-01

    Pneumatic active control of asymmetric vortical flows around a slender pointed forebody is investigated using the three dimensional solution for the compressible thin-layer Navier-Stokes equation. The computational applications cover the normal and tangential injection control of asymmetric flows around a 5 degree semi-apex angle cone at a 40 degree angle of attack, 1.4 freestream Mach number and 6 x 10(exp 6) freestream Reynolds number (based on the cone length). The effective tangential angle range of 67.5 approaches minus 67.5 degrees is used for both normal and tangential ports of injection. The effective axial length of injection is varied from 0.03 to 0.05. The computational solver uses the implicit, upwind, flux difference splitting finite volume scheme, and the grid consists of 161 x 55 x 65 points in the wrap around, normal and axial directions, respectively. The results show that tangential injection is more effective than normal injection.

  13. Power training using pneumatic machines vs. plate-loaded machines to improve muscle power in older adults.

    PubMed

    Balachandran, Anoop T; Gandia, Kristine; Jacobs, Kevin A; Streiner, David L; Eltoukhy, Moataz; Signorile, Joseph F

    2017-11-01

    Power training has been shown to be more effective than conventional resistance training for improving physical function in older adults; however, most trials have used pneumatic machines during training. Considering that the general public typically has access to plate-loaded machines, the effectiveness and safety of power training using plate-loaded machines compared to pneumatic machines is an important consideration. The purpose of this investigation was to compare the effects of high-velocity training using pneumatic machines (Pn) versus standard plate-loaded machines (PL). Independently-living older adults, 60years or older were randomized into two groups: pneumatic machine (Pn, n=19) and plate-loaded machine (PL, n=17). After 12weeks of high-velocity training twice per week, groups were analyzed using an intention-to-treat approach. Primary outcomes were lower body power measured using a linear transducer and upper body power using medicine ball throw. Secondary outcomes included lower and upper body muscle muscle strength, the Physical Performance Battery (PPB), gallon jug test, the timed up-and-go test, and self-reported function using the Patient Reported Outcomes Measurement Information System (PROMIS) and an online video questionnaire. Outcome assessors were blinded to group membership. Lower body power significantly improved in both groups (Pn: 19%, PL: 31%), with no significant difference between the groups (Cohen's d=0.4, 95% CI (-1.1, 0.3)). Upper body power significantly improved only in the PL group, but showed no significant difference between the groups (Pn: 3%, PL: 6%). For balance, there was a significant difference between the groups favoring the Pn group (d=0.7, 95% CI (0.1, 1.4)); however, there were no statistically significant differences between groups for PPB, gallon jug transfer, muscle muscle strength, timed up-and-go or self-reported function. No serious adverse events were reported in either of the groups. Pneumatic and plate-loaded machines were effective in improving lower body power and physical function in older adults. The results suggest that power training can be safely and effectively performed by older adults using either pneumatic or plate-loaded machines. Copyright © 2017 Elsevier Inc. All rights reserved.

  14. Soft Snakes: Construction, Locomotion, and Control

    NASA Astrophysics Data System (ADS)

    Branyan, Callie; Courier, Taylor; Fleming, Chloe; Remaley, Jacquelin; Hatton, Ross; Menguc, Yigit

    We fabricated modular bidirectional silicone pneumatic actuators to build a soft snake robot, applying geometric models of serpenoid swimmers to identify theoretically optimal gaits to realize serpentine locomotion. With the introduction of magnetic connections and elliptical cross-sections in fiber-reinforced modules, we can vary the number of continuum segments in the snake body to achieve more supple serpentine motion in a granular media. The performance of these gaits is observed using a motion capture system and efficiency is assessed in terms of pressure input and net displacement. These gaits are optimized using our geometric soap-bubble method of gait optimization, demonstrating the applicability of this tool to soft robot control and coordination.

  15. The all electric airplane-benefits and challenges

    NASA Technical Reports Server (NTRS)

    Spitzer, C. R.; Hood, R. V.

    1982-01-01

    The all electric aircraft considered in the present investigation is an aircraft which has digital flight crucial controls, electromechanical actuators, and electrical secondary power. There are no hydraulic or pneumatic systems. The characteristics of an all electric aircraft are related to reduced acquisition cost, reduced weight, reduced fuel consumption, increased reliability, reduced support equipment, simpler maintenance, an expanded flight envelope, and improved survivability. An additional benefit is the dramatically increased design flexibility and mission adaptability. However, the implementation of the all electric aircraft concept requires the resolution of a number of major technology issues. Issues in the digital flight controls area are related to achieving the required levels of safety and reliability in a cost effective manner. Other challenges which have to be met are concerned with electromechanical actuators, environmental control and ice protection systems, and engine technology.

  16. MRI compatibility of robot actuation techniques--a comparative study.

    PubMed

    Fischer, Gregory S; Krieger, Axel; Iordachita, Iulian; Csoma, Csaba; Whitcomb, Louis L; Gabor, Fichtinger

    2008-01-01

    This paper reports an experimental evaluation of the following three different MRI-compatible actuators: a Shinsei ultrasonic motor a Nanomotion ultrasonic motor and a pneumatic cylinder actuator. We report the results of a study comparing the effect of these actuators on the signal to noise ratio (SNR) of MRJ images under a variety of experimental conditions. Evaluation was performed with the controller inside and outside the scanner room and with both 1.5T and 3T MRI scanners. Pneumatic cylinders function with no loss of SNR with controller both inside and outside of the scanner room. The Nanomotion motor performs with moderate loss of SNR when moving during imaging. The Shinsei is unsuitable for motion during imaging. All may be used when motion is appropriately interleaved with imaging cycles.

  17. Outflow monitoring of a pneumatic ventricular assist device using external pressure sensors.

    PubMed

    Kang, Seong Min; Her, Keun; Choi, Seong Wook

    2016-08-25

    In this study, a new algorithm was developed for estimating the pump outflow of a pneumatic ventricular assist device (p-VAD). The pump outflow estimation algorithm was derived from the ideal gas equation and determined the change in blood-sac volume of a p-VAD using two external pressure sensors. Based on in vitro experiments, the algorithm was revised to consider the effects of structural compliance caused by volume changes in an implanted unit, an air driveline, and the pressure difference between the sensors and the implanted unit. In animal experiments, p-VADs were connected to the left ventricles and the descending aorta of three calves (70-100 kg). Their outflows were estimated using the new algorithm and compared to the results obtained using an ultrasonic blood flow meter (UBF) (TS-410, Transonic Systems Inc., Ithaca, NY, USA). The estimated and measured values had a Pearson's correlation coefficient of 0.864. The pressure sensors were installed at the external controller and connected to the air driveline on the same side as the external actuator, which made the sensors easy to manage.

  18. Design of flat pneumatic artificial muscles

    NASA Astrophysics Data System (ADS)

    Wirekoh, Jackson; Park, Yong-Lae

    2017-03-01

    Pneumatic artificial muscles (PAMs) have gained wide use in the field of robotics due to their ability to generate linear forces and motions with a simple mechanism, while remaining lightweight and compact. However, PAMs are limited by their traditional cylindrical form factors, which must increase radially to improve contraction force generation. Additionally, this form factor results in overly complicated fabrication processes when embedded fibers and sensor elements are required to provide efficient actuation and control of the PAMs while minimizing the bulkiness of the overall robotic system. In order to overcome these limitations, a flat two-dimensional PAM capable of being fabricated using a simple layered manufacturing process was created. Furthermore, a theoretical model was developed using Von Karman’s formulation for large deformations and the energy methods. Experimental characterizations of two different types of PAMs, a single-cell unit and a multi-cell unit, were performed to measure the maximum contraction lengths and forces at input pressures ranging from 0 to 150 kPa. Experimental data were then used to verify the fidelity of the theoretical model.

  19. Software For Graphical Representation Of A Network

    NASA Technical Reports Server (NTRS)

    Mcallister, R. William; Mclellan, James P.

    1993-01-01

    System Visualization Tool (SVT) computer program developed to provide systems engineers with means of graphically representing networks. Generates diagrams illustrating structures and states of networks defined by users. Provides systems engineers powerful tool simplifing analysis of requirements and testing and maintenance of complex software-controlled systems. Employs visual models supporting analysis of chronological sequences of requirements, simulation data, and related software functions. Applied to pneumatic, hydraulic, and propellant-distribution networks. Used to define and view arbitrary configurations of such major hardware components of system as propellant tanks, valves, propellant lines, and engines. Also graphically displays status of each component. Advantage of SVT: utilizes visual cues to represent configuration of each component within network. Written in Turbo Pascal(R), version 5.0.

  20. Independent Orbiter Assessment (IOA): Analysis of the orbiter main propulsion system

    NASA Technical Reports Server (NTRS)

    Mcnicoll, W. J.; Mcneely, M.; Holden, K. A.; Emmons, T. E.; Lowery, H. J.

    1987-01-01

    The results of the Independent Orbiter Assessment (IOA) of the Failure Modes and Effects Analysis (FMEA) and Critical Items List (CIL) are presented. The IOA approach features a top-down analysis of the hardware to determine failure modes, criticality, and potential critical items (PCIs). To preserve independence, this analysis was accomplished without reliance upon the results contained within the NASA FMEA/CIL documentation. The independent analysis results for the Orbiter Main Propulsion System (MPS) hardware are documented. The Orbiter MPS consists of two subsystems: the Propellant Management Subsystem (PMS) and the Helium Subsystem. The PMS is a system of manifolds, distribution lines and valves by which the liquid propellants pass from the External Tank (ET) to the Space Shuttle Main Engines (SSMEs) and gaseous propellants pass from the SSMEs to the ET. The Helium Subsystem consists of a series of helium supply tanks and their associated regulators, check valves, distribution lines, and control valves. The Helium Subsystem supplies helium that is used within the SSMEs for inflight purges and provides pressure for actuation of SSME valves during emergency pneumatic shutdowns. The balance of the helium is used to provide pressure to operate the pneumatically actuated valves within the PMS. Each component was evaluated and analyzed for possible failure modes and effects. Criticalities were assigned based on the worst possible effect of each failure mode. Of the 690 failure modes analyzed, 349 were determined to be PCIs.

  1. Microbioreactors with microfluidic control and a user-friendly connection to the actuator hardware

    NASA Astrophysics Data System (ADS)

    Buchenauer, A.; Funke, M.; Büchs, J.; Mokwa, W.; Schnakenberg, U.

    2009-07-01

    In this study, an array of microbioreactors based on the format of 48-well microtiter plates (MTPs) is presented. The process parameters pH and biomass are monitored online using commercially available optical sensor technology. A microfluidic device dispenses acid or base individually into each well for controlling the pH of fermentations. Fluid volumes from 72 nL to 940 nL can be supplied with valve opening times between 10 ms and 200 ms. One microfluidic device is capable of supplying four wells from two reservoirs. Up to four microfluidic devices can be integrated on the area of a prototype MTP. The devices are fabricated in polydimethylsiloxane (PDMS) using soft lithographic techniques and utilize pneumatically actuated microvalves. During fermentations, the microbioreactor is clamped to an orbital shaker and a temporary pneumatic connection guides the externally controlled pressurized air to the microfluidic device. Finally, fermentations of Escherichia coli in the presence and absence of pH control are carried out in the microbioreactor system over 18 h. During the fermentation the pH of the cultures is continuously monitored by means of optodes. An ammonia solution or phosphoric acid is dispensed to adjust the pH if it differs from the set point of 7.2. In a controlled culture, the pH can be sustained within 7.0 to 7.3 while the pH in an uncontrolled culture ranges between 6.5 and 9.0. This microbioreactor demonstrates the possibility of pH-controlled fermentations in micro-scale. The process control and the user friendly connection to the actuation hardware provide an easy handling comparable to standard MTPs.

  2. Evaluation of a pneumatic boot deicing system on a general aviation wing model

    NASA Technical Reports Server (NTRS)

    Albright, A. E.; Kohlman, D. L.; Schweikhard, W. G.; Evanich, P.

    1981-01-01

    The aerodynamic characteristics of a typical modern general aviation airfoil were investigated with and without a pneumatic boot ice protection system. The ice protection effectiveness of the boot was studied. This includes the change in drag on the airfoil with the boot inflated and deflated, the change in drag due to primary and residual ice formation, drag change due to cumulative residual ice formation, and parameters affecting boot effectiveness. Boot performance was not affected by tunnel total temperature or velocity. Marginal effect in performance was associated with angle of attack. Significant effects on performance were caused by variations in droplet size, LWC, ice cap thickness inflation pressure, and surface treatment.

  3. Development of integrated, zero-G pneumatic transporter/rotating paddle incinerator/catalytic afterburner subsystem for processing human wastes on board spacecraft

    NASA Technical Reports Server (NTRS)

    Fields, S. F.; Labak, L. J.; Honegger, R. J.

    1974-01-01

    A four component system was developed which consists of a particle size reduction mechanism, a pneumatic waste transport system, a rotating-paddle incinerator, and a catalytic afterburner to be integrated into a six-man, zero-g subsystem for processing human wastes on board spacecraft. The study included the development of different concepts or functions, the establishment of operational specifications, and a critical evaluation for each of the four components. A series of laboratory tests was run, and a baseline subsystem design was established. An operational specification was also written in preparation for detailed design and testing of this baseline subsystem.

  4. Multigait soft robot

    PubMed Central

    Shepherd, Robert F.; Ilievski, Filip; Choi, Wonjae; Morin, Stephen A.; Stokes, Adam A.; Mazzeo, Aaron D.; Chen, Xin; Wang, Michael; Whitesides, George M.

    2011-01-01

    This manuscript describes a unique class of locomotive robot: A soft robot, composed exclusively of soft materials (elastomeric polymers), which is inspired by animals (e.g., squid, starfish, worms) that do not have hard internal skeletons. Soft lithography was used to fabricate a pneumatically actuated robot capable of sophisticated locomotion (e.g., fluid movement of limbs and multiple gaits). This robot is quadrupedal; it uses no sensors, only five actuators, and a simple pneumatic valving system that operates at low pressures (< 10 psi). A combination of crawling and undulation gaits allowed this robot to navigate a difficult obstacle. This demonstration illustrates an advantage of soft robotics: They are systems in which simple types of actuation produce complex motion. PMID:22123978

  5. Development of the transtibial prosthesis controlled pneumatically and electrically by microcomputer system.

    PubMed

    Shimada, Youichi; Terayama, Yukio

    2006-01-01

    This report represents the development of the prototype transtibial prosthesis to assist a smooth and comfortable walking for an unilateral amputee. This prosthesis is composed of two air cylinders, solenoid valves, portable and small air tank for compressed air storage, a multiple sensor system and a microprocessor. Two air cylinders are located around the rods to act as antagonistic and agonistic muscles. The system causes flexion and extension of the foot plate jointed at the ankle with compressed air, injected -or discharged via a solenoid or electromagnetic valves. The valves or solenoids are controlled with a microprocessor (Microchip Technology Inc., PIC16F876), the microprocessor generates control signals to the interface circuits for valve opening and closing consistent with the foot position during the walking phase. The control patterns generated in the microprocessor are modified with feedback from the touch sensor, ankle joint angle sensor and the two dimensional acceleration sensor. The primary walking pattern for an individual amputee should be developed through the gait analysis with video.

  6. Critical parts are stored and shipped in environmentally controlled reusable container

    NASA Technical Reports Server (NTRS)

    Kummerfeld, K. R.

    1966-01-01

    Environmentally controlled, hermetically sealed, reusable metal cabinet with storage drawers is used to ship and store sensitive electronic, pneumatic, or hydraulic parts or medical supplies under extreme weather or handling conditions. This container is compatible with on-site and transportation handling facilities.

  7. Design and Testing of an Erosion Resistant Ultrasonic De-Icing System for Rotorcraft Blades

    DTIC Science & Technology

    2013-08-01

    need for pneumatic slip rings , and the potential of holes located on the blade to clog. The 11-gallon tank adds significant weight and only protects...icing were the need of heavy pneumatic slip rings , and the need for a coating able to protect against both rain and sand erosion. 14 1.1.4.6...feet in diameter at an RPM of 1000 (see Figure 49). Four slip rings carry 48 signal channels and 24 power channels from the rotating frame of the

  8. Design and motion control of bioinspired humanoid robot head from servo motors toward artificial muscles

    NASA Astrophysics Data System (ADS)

    Almubarak, Yara; Tadesse, Yonas

    2017-04-01

    The potential applications of humanoid robots in social environments, motivates researchers to design, and control biomimetic humanoid robots. Generally, people are more interested to interact with robots that have similar attributes and movements to humans. The head is one of most important part of any social robot. Currently, most humanoid heads use electrical motors, pneumatic actuators, and shape memory alloy (SMA) actuators for actuation. Electrical and pneumatic actuators take most of the space and would cause unsmooth motions. SMAs are expensive to use in humanoids. Recently, in many robotic projects, Twisted and Coiled Polymer (TCP) artificial muscles are used as linear actuators which take up little space compared to the motors. In this paper, we will demonstrate the designing process and motion control of a robotic head with TCP muscles. Servo motors and artificial muscles are used for actuating the head motion, which have been controlled by a cost efficient ARM Cortex-M7 based development board. A complete comparison between the two actuators is presented.

  9. Control performances of a piezoactuator direct drive valve system at high temperatures with thermal insulation

    NASA Astrophysics Data System (ADS)

    Han, Yung-Min; Han, Chulhee; Kim, Wan Ho; Seong, Ho Yong; Choi, Seung-Bok

    2016-09-01

    This technical note presents control performances of a piezoactuator direct drive valve (PDDV) operated at high temperature environment. After briefly discussing operating principle and mechanical dimensions of the proposed PDDV, an appropriate size of the PDDV is manufactured. As a first step, the temperature effect on the valve performance is experimentally investigated by measuring the spool displacement at various temperatures. Subsequently, the PDDV is thermally insulated using aerogel and installed in a large-size heat chamber in which the pneumatic-hydraulic cylinders and sensors are equipped. A proportional-integral-derivative feedback controller is then designed and implemented to control the spool displacement of the valve system. In this work, the spool displacement is chosen as a control variable since it is directly related to the flow rate of the valve system. Three different sinusoidal displacements with different frequencies of 1, 10 and 50 Hz are used as reference spool displacement and tracking controls are undertaken up to 150 °C. It is shown that the proposed PDDV with the thermal insulation can provide favorable control responses without significant tracking errors at high temperatures.

  10. [Modern pneumatic weapons and injuries they cause].

    PubMed

    Kozachenko, I N

    2013-01-01

    The data on the history of development and further improvement of pneumatic weapons are presented with special reference to specific features of different types and varieties of these weapons, cartridges for them, and the sphere of their application. Investigations into peculiarities of damages caused by high-capacity pneumatic weapons to the objects of forensic medical expertise affected from different distances are reviewed. Results of forensic medical expertise and clinical studies on the structure of body injuries inflicted by gunshots from pneumatic weapons to the human body are discussed. The author emphasizes the necessity of developing up-to-date terminology and classification of gunshot injuries caused by shooting from pneumatic weapons.

  11. The space shuttle program from challenge to achievement: Space exploration rolling on tires

    NASA Technical Reports Server (NTRS)

    Felder, G. L.

    1985-01-01

    The Space Shuttle Transportation System is the first space program to employ the pneumatic tire as a part of space exploration. For aircraft tires, this program establishes new expectations as to what constitutes acceptable performance within a set of tough environmental and operational conditions. Tire design, stresses the usual low weight, high load, high speed, and excellent air retention features but at extremes well outside industry standards. Tires will continue to be an integral part of the Shuttle's landing phase in the immediate future since they afford a unique combination of directional control, braking traction, flotation and shock absorption not available by other systems.

  12. Pneumatic Planetary Regolith Feed System for In-Situ Resource Utilization

    NASA Technical Reports Server (NTRS)

    Mantovani, James G.; Mueller, Robert P.; Townsend, Ivan I.; Craft, Jack; Zacny, Kris

    2010-01-01

    The NASA In-situ Resource Utilization (ISRU) project requires a regolith feed system that can transfer lunar regolith several meters vertically into a chemical reactor for oxygen production on the moon.

  13. Method of sections in analytical calculations of pneumatic tires

    NASA Astrophysics Data System (ADS)

    Tarasov, V. N.; Boyarkina, I. V.

    2018-01-01

    Analytical calculations in the pneumatic tire theory are more preferable in comparison with experimental methods. The method of section of a pneumatic tire shell allows to obtain equations of intensities of internal forces in carcass elements and bead rings. Analytical dependencies of intensity of distributed forces have been obtained in tire equator points, on side walls (poles) and pneumatic tire bead rings. Along with planes in the capacity of secant surfaces cylindrical surfaces are used for the first time together with secant planes. The tire capacity equation has been obtained using the method of section, by means of which a contact body is cut off from the tire carcass along the contact perimeter by the surface which is normal to the bearing surface. It has been established that the Laplace equation for the solution of tasks of this class of pneumatic tires contains two unknown values that requires the generation of additional equations. The developed computational schemes of pneumatic tire sections and new equations allow to accelerate the pneumatic tire structure improvement process during engineering.

  14. Development of pneumatic actuator with low-wave reflection characteristics

    NASA Astrophysics Data System (ADS)

    Chang, H.; Tsung, T. T.; Jwo, C. S.; Chiang, J. C.

    2010-08-01

    This study aims at the development of a less reflective electromagnetic pneumatic actuator often used in the anechoic chamber. Because a pneumatic actuator on the market is not appropriate for use in such a chamber and a metallic one has high dielectric constant which generates reflective electromagnetic waves to influence test parameters in the chamber. The newly developed pneumatic actuator is made from low dielectric constant plastics with less reflective of electromagnetic. A turbine-type air motor is used to develop the pneumatic actuator and a employ Prony tester is used to run the brake horsepower test for the performance test of pneumatic actuator. Test results indicate that the pneumatic actuator in the minimal starting flow is 17 l/min, and it generates a brake horsepower of 48 mW; in the maximum flow is 26 l/min, it generates a brake horsepower of 108 mW. Therefore, it works with a torque between 0.24 N-m and 0.55 N-m, and such a torque will be sufficient to drive the target button.

  15. Venous Hemodynamics After Total Hip Arthroplasty: A Comparison Between Portable vs Stationary Pneumatic Compression Devices and the Effect of Body Position.

    PubMed

    Berliner, Jonathan L; Ortiz, Philippe A; Lee, Yuo-Yu; Miller, Theodore T; Westrich, Geoffrey H

    2018-01-01

    Improvements in device design have allowed for portable pneumatic compression devices (PPCDs). However, portability results in smaller pumps that move less blood. Additionally, although patients often stand when wearing PPCDs, few studies have evaluated the hemodynamic effects of PCDs while standing. A crossover study was performed to compare a PPCD (ActiveCare+S.F.T.; Medical Compression Systems, Or Akiva, Israel) to a stationary pneumatic compression device (SPCD) (VenaFlow; DJO Global, Carlsbad, CA) on hemodynamics in supine and standing positions among 2 cohorts composed of 10 controls and 10 total hip arthroplasty patients. Differences in baseline peak venous velocity (PVV), PVV with each PCD, and delta PVV with each PCD were assessed. A multivariate analysis was performed to examine differences between cohorts, devices, and position. In both positions, the SPCD demonstrated a larger change in PVV when compared to the PPCD (P < .001). The total hip arthroplasty group had a greater delta PVV while standing when considering both PCDs together (P < .001). When considering both cohorts, delta PVV was greater while standing, only when the SPCD was used (P < .001). There was no difference between standing and supine positions when the PPCD was used. The SPCD demonstrated a greater capacity to increase PPV in the supine and standing positions. The SPCD generated greater values of PVV and delta PVV in the standing position. Although these results demonstrate a difference between devices, it is important to establish the PVV necessary to prevent VTE before one is considered more effective. Copyright © 2017 Elsevier Inc. All rights reserved.

  16. The M68HC11 gripper controller electronics

    NASA Technical Reports Server (NTRS)

    Kelley, Robert B.; Bethel, Jeffrey

    1991-01-01

    This document describes the instrumentation, operational theory, circuit implementation, calibration procedures, and general notes for the CIRSSE general purpose pneumatic hand. The mechanical design and the control software are discussed. The circuit design, PCB layout, hand instrumentation, and controller construction described in detail in this document are the result of a senior project.

  17. Networked vision system using a Prolog controller

    NASA Astrophysics Data System (ADS)

    Batchelor, B. G.; Caton, S. J.; Chatburn, L. T.; Crowther, R. A.; Miller, J. W. V.

    2005-11-01

    Prolog offers a very different style of programming compared to conventional languages; it can define object properties and abstract relationships in a way that Java, C, C++, etc. find awkward. In an accompanying paper, the authors describe how a distributed web-based vision systems can be built using elements that may even be located on different continents. One particular system of this general type is described here. The top-level controller is a Prolog program, which operates one, or more, image processing engines. This type of function is natural to Prolog, since it is able to reason logically using symbolic (non-numeric) data. Although Prolog is not suitable for programming image processing functions directly, it is ideal for analysing the results derived by an image processor. This article describes the implementation of two systems, in which a Prolog program controls several image processing engines, a simple robot, a pneumatic pick-and-place arm), LED illumination modules and a various mains-powered devices.

  18. Flight evaluation of a pneumatic system for unsteady pressure measurements using conventional sensors

    NASA Technical Reports Server (NTRS)

    Curry, Robert E.; Gilyard, Glenn B.

    1989-01-01

    A flight experiment was conducted to evaluate a pressure measurement system which uses pneumatic tubing and remotely located electronically scanned pressure transducer modules for in-flight unsteady aerodynamic studies. A parametric study of tubing length and diameter on the attenuation and lag of the measured signals was conducted. The hardware was found to operate satisfactorily at rates of up to 500 samples/sec per port in flight. The signal attenuation and lag due to tubing were shown to increase with tubing length, decrease with tubing diameter, and increase with altitude over the ranges tested. Measurable signal levels were obtained for even the longest tubing length tested, 4 ft, at frequencies up to 100 Hz. This instrumentation system approach provides a practical means of conducting detailed unsteady pressure surveys in flight.

  19. Water gate array for current flow or tidal movement pneumatic harnessing system

    DOEpatents

    Gorlov, Alexander M.

    1991-01-01

    The invention, which provides a system for harnessing power from current flow or tidal movement in a body of water, comprises first and second hydro-pneumatic chambers each having ingress and egress below the water surface near the river or ocean floor and water gates operative to open or seal the ports to the passage of water. In an exemplary embodiment, the gates are sychronized by shafts so that the ingress ports of each chamber are connected to the egress ports of each other chamber. Thus, one set of gates is closed, while the other is open, thereby allowing water to flow into one chamber and build air pressure therein and allowing water to flow out of the other chamber and create a partial vacuum therein. A pipe connects the chambers, and an air turbine harnesses the air movement within the pipe. When water levels are equilibrated, the open set of gates is closed by a counterweight, and the other set is allowed to open by natural force of the water differential. The water gates may be comprised of a plurality of louvers which are ganged for simultaneous opening and closing. The system is designed to operate with air turbines or other pneumatic devices. Its design minimizes construction cost and environmental impact, yet provides a clean renewable energy source.

  20. NASA. Langley Research Center dry powder towpreg system

    NASA Technical Reports Server (NTRS)

    Baucom, Robert M.; Marchello, Joseph M.

    1990-01-01

    Dry powder polymer impregnated carbon fiber tows were produced for preform weaving and composite materials molding applications. In the process, fluidized powder is deposited on spread tow bundles and melted on the fibers by radiant heating to adhere the polymer to the fiber. Unit design theory and operating correlations were developed to provide the basis for scale up of the process to commercial operation. Special features of the operation are the pneumatic tow spreader, fluidized bed, resin feeder, and quality control system. Bench scale experiments, at tow speeds up to 50 cm/sec, demonstrated that process variables can be controlled to produce weavable LARC-TPI carbon fiber towpreg. The towpreg made by the dry powder process was formed into unidirectional fiber moldings and was woven and molded into preform material of good quality.

  1. Welding at the Kennedy Space Center.

    NASA Technical Reports Server (NTRS)

    Clautice, W. E.

    1973-01-01

    Brief description of the nature of the mechanical equipment at a space launch complex from a welding viewpoint. including an identification of the major welding applications used in the construction of this complex. The role played by welding in the ground support equipment is noted, including the welded structures and systems required in the vehicle assembly building, the mobile launchers, transporters, mobile service structure, launch pad and launch site, the propellants system, the pneumatics system, and the environmental control system. The welding processes used at the Kennedy Space Center are reviewed, and a particularly detailed account is given of the design and fabrication of the liquid hydrogen and liquid oxygen storage spheres and piping. Finally, the various methods of testing and inspecting the storage spheres are cited.

  2. Variable camber wing based on pneumatic artificial muscles

    NASA Astrophysics Data System (ADS)

    Yin, Weilong; Liu, Libo; Chen, Yijin; Leng, Jinsong

    2009-07-01

    As a novel bionic actuator, pneumatic artificial muscle has high power to weight ratio. In this paper, a variable camber wing with the pneumatic artificial muscle is developed. Firstly, the experimental setup to measure the static output force of pneumatic artificial muscle is designed. The relationship between the static output force and the air pressure is investigated. Experimental result shows the static output force of pneumatic artificial muscle decreases nonlinearly with increasing contraction ratio. Secondly, the finite element model of the variable camber wing is developed. Numerical results show that the tip displacement of the trailing-edge increases linearly with increasing external load and limited with the maximum static output force of pneumatic artificial muscles. Finally, the variable camber wing model is manufactured to validate the variable camber concept. Experimental result shows that the wing camber increases with increasing air pressure and that it compare very well with the FEM result.

  3. Temporo-sylvian arachnoidal cyst and an extreme pneumatization of the cranial sinuses: a case report.

    PubMed

    Zara, Gabriella; Ponza, Isabella; Citton, Valentina; Manara, Renzo

    2010-11-01

    We present a patient who showed MRI evidence of a giant temporo-sylvian arachnoidal cyst of the left hemisphere and an extreme pneumatization of the sphenoid and frontal sinuses. No sign of mass effect or cerebral atrophy was detected. This patient presented a deficit of memory and control functions, but quality of life was not affected. Surgery was not performed. Arachnoidal cyst and anatomic variants of the sinus region have not a common etiology. This is the first report that describes a giant temporo-sylvian arachnoidal cyst with anatomic variants of the paranasal sinuses. Copyright © 2010 Elsevier B.V. All rights reserved.

  4. Main Oxidizer Valve Design

    NASA Technical Reports Server (NTRS)

    Addona, Brad; Eddleman, David

    2015-01-01

    A developmental Main Oxidizer Valve (MOV) was designed by NASA-MSFC using additive manufacturing processes. The MOV is a pneumatically actuated poppet valve to control the flow of liquid oxygen to an engine's injector. A compression spring is used to return the valve to the closed state when pneumatic pressure is removed from the valve. The valve internal parts are cylindrical in shape, which lends itself to traditional lathe and milling operations. However, the valve body represents a complicated shape and contains the majority of the mass of the valve. Additive manufacturing techniques were used to produce a part that optimized mass and allowed for design features not practical with traditional machining processes.

  5. Parameter tuning method for dither compensation of a pneumatic proportional valve with friction

    NASA Astrophysics Data System (ADS)

    Wang, Tao; Song, Yang; Huang, Leisheng; Fan, Wei

    2016-05-01

    In the practical application of pneumatic control devices, the nonlinearity of a pneumatic control valve become the main factor affecting the control effect, which comes mainly from the dynamic friction force. The dynamic friction inside the valve may cause hysteresis and a dead zone. In this paper, a dither compensation mechanism is proposed to reduce negative effects on the basis of analyzing the mechanism of friction force. The specific dither signal (using a sinusoidal signal) was superimposed on the control signal of the valve. Based on the relationship between the parameters of the dither signal and the inherent characteristics of the proportional servo valve, a parameter tuning method was proposed, which uses a displacement sensor to measure the maximum static friction inside the valve. According to the experimental results, the proper amplitude ranges are determined for different pressures. In order to get the optimal parameters of the dither signal, some dither compensation experiments have been carried out on different signal amplitude and gas pressure conditions. Optimal parameters are determined under two kinds of pressure conditions. Using tuning parameters the valve spool displacement experiment has been taken. From the experiment results, hysteresis of the proportional servo valve is significantly reduced. And through simulation and experiments, the cut-off frequency of the proportional valve has also been widened. Therefore after adding the dither signal, the static and dynamic characteristics of the proportional valve are both improved to a certain degree. This research proposes a parameter tuning method of dither signal, and the validity of the method is verified experimentally.

  6. Microfluidic valve array control system integrating a fluid demultiplexer circuit

    NASA Astrophysics Data System (ADS)

    Kawai, Kentaro; Arima, Kenta; Morita, Mizuho; Shoji, Shuichi

    2015-06-01

    This paper proposes an efficient control method for the large-scale integration of microvalves in microfluidic systems. The proposed method can control 2n individual microvalves with 2n + 2 control lines (where n is an integer). The on-chip valves are closed by applying pressure to a control line, similar to conventional pneumatic microvalves. Another control line closes gate valves between the control line to the on-chip valves and the on-chip valves themselves, to preserve the state of the on-chip valves. The remaining control lines select an activated gate valve. While the addressed gate valve is selected by the other control lines, the corresponding on-chip valve is actuated by applying input pressure to the control line to the on-chip valves. Using this method would substantially reduce the number of world-to-chip connectors and off-chip valve controllers. Experiments conducted using a fabricated 28 microvalve array device, comprising 256 individual on-chip valves controlled with 18 (2   ×   8 + 2) control lines, yielded switching speeds for the selected on-chip valve under 90 ms.

  7. Fluid Power Multi-actuator Circuit Board with Microcomputer Control Option.

    ERIC Educational Resources Information Center

    McKechnie, R. E.; Vickers, G. W.

    1981-01-01

    Describes a portable fluid power engineering laboratory and class demonstration apparatus designed to enable students to design, build, and test multi-actuator circuits. Features a variety of standard pneumatic values and actuators fitted with quick disconnect couplings. Discusses sequencing circuit boards, microcomputer control, cost, and…

  8. Pneumatic wrench retains or discharges nuts or bolts as desired

    NASA Technical Reports Server (NTRS)

    Bouille, J. R.

    1966-01-01

    Pneumatic wrench grips, screws or unscrews, and discharges a nut or bolt as desired. The device consists of a standard pneumatic wrench modified with a special hex bolt head socket assembly and a diaphragm air cylinder.

  9. Fluidic-thermochromic display device

    NASA Technical Reports Server (NTRS)

    Grafstein, D.; Hilborn, E. H.

    1968-01-01

    Fluidic decoder and display device has low-power requirements for temperature control of thermochromic materials. An electro-to-fluid converter translates incoming electrical signals into pneumatics signal of sufficient power to operate the fluidic logic elements.

  10. Pneumatic conveyance apparatus and process

    DOEpatents

    Heckendorn, Frank M.; Matzolf, Athneal D.; Hera, Kevin R.

    2010-05-04

    A pneumatic nozzle capable of removing dry solid debris, liquids, and mixtures of solid and liquid waste is provided. The pneumatic nozzle uses a pressurized gas stream to push materials through the nozzle. The force of a pressurized gas stream provides a partial vacuum to allow material to be introduced into an opening of a nozzle via a slight suction force. Thereafter, individual particles and materials introduced into the pneumatic nozzle are pushed by a stream of pressurized gas through the nozzle.

  11. Cranial base morphology and temporal bone pneumatization in Asian Homo erectus.

    PubMed

    Balzeau, Antoine; Grimaud-Hervé, Dominique

    2006-10-01

    The external morphological features of the temporal bone are used frequently to determine taxonomic affinities of fossils of the genus Homo. Temporal bone pneumatization has been widely studied in great apes and in early hominids. However, this feature is rarely examined in the later hominids, particularly in Asian Homo erectus. We provide a comparative morphological and quantitative analysis of Asian Homo erectus from the sites of Ngandong, Sambungmacan, and Zhoukoudian, and of Neandertals and anatomically modern Homo sapiens in order to discuss causes and modalities of temporal bone pneumatization during hominid evolution. The evolution of temporal bone pneumatization in the genus Homo is more complex than previously described. Indeed, the Zhoukoudian fossils have a unique pattern of temporal bone pneumatization, whereas Ngandong and Sambungmacan fossils, as well as the Neandertals, more closely resemble the modern human pattern. Moreover, these Chinese fossils are characterized by a wide midvault and a relatively narrow occipital bone. Our results support the point of view that cell development does not play an active role in determining cranial base morphology. Instead, pneumatization is related to available space and to temporal bone morphology, and its development is related to correlated morphology and the relative disposition of the bones and cerebral lobes. Because variation in pneumatization is extensive within the same species, the phyletic implications of pneumatization are limited in the taxa considered here.

  12. Electro pneumatic trainer embedded with programmable integrated circuit (PIC) microcontroller and graphical user interface platform for aviation industries training purposes

    NASA Astrophysics Data System (ADS)

    Burhan, I.; Azman, A. A.; Othman, R.

    2016-10-01

    An electro pneumatic trainer embedded with programmable integrated circuit (PIC) microcontroller and Visual Basic (VB) platform is fabricated as a supporting tool to existing teaching and learning process, and to achieve the objectives and learning outcomes towards enhancing the student's knowledge and hands-on skill, especially in electro pneumatic devices. The existing learning process for electro pneumatic courses conducted in the classroom does not emphasize on simulation and complex practical aspects. VB is used as the platform for graphical user interface (GUI) while PIC as the interface circuit between the GUI and hardware of electro pneumatic apparatus. Fabrication of electro pneumatic trainer interfacing between PIC and VB has been designed and improved by involving multiple types of electro pneumatic apparatus such as linear drive, air motor, semi rotary motor, double acting cylinder and single acting cylinder. Newly fabricated electro pneumatic trainer microcontroller interface can be programmed and re-programmed for numerous combination of tasks. Based on the survey to 175 student participants, 97% of the respondents agreed that the newly fabricated trainer is user friendly, safe and attractive, and 96.8% of the respondents strongly agreed that there is improvement in knowledge development and also hands-on skill in their learning process. Furthermore, the Lab Practical Evaluation record has indicated that the respondents have improved their academic performance (hands-on skills) by an average of 23.5%.

  13. 21 CFR 870.2780 - Hydraulic, pneumatic, or photoelectric plethysmographs.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Monitoring Devices..., pneumatic, or photoelectric plethysmograph is a device used to estimate blood flow in a region of the body using hydraulic, pneumatic, or photoelectric measurement techniques. (b) Classification. Class II...

  14. 21 CFR 870.2780 - Hydraulic, pneumatic, or photoelectric plethysmographs.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Monitoring Devices..., pneumatic, or photoelectric plethysmograph is a device used to estimate blood flow in a region of the body using hydraulic, pneumatic, or photoelectric measurement techniques. (b) Classification. Class II...

  15. 21 CFR 870.2780 - Hydraulic, pneumatic, or photoelectric plethysmographs.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Monitoring Devices..., pneumatic, or photoelectric plethysmograph is a device used to estimate blood flow in a region of the body using hydraulic, pneumatic, or photoelectric measurement techniques. (b) Classification. Class II...

  16. [The forensic medical characteristics of the entrance bullet holes created by the shots from pneumatic rifles].

    PubMed

    Legin, G A; Bondarchuk, A O; Perebetjuk, A N

    2015-01-01

    The objective of the present study was to compare the injurious action of three types of the bullets for the pneumatic weapons shot from different distances using the Gamo pump air pistol and the BAM B22-1 pneumatic rifle. The following four kinds of the bullets were tested: "the fireball", "Luman cap 0.3", "Luman Field Target 0.68" and "DIABOLO". It was experimentally shown that the injurious action of the bullets fired from the same distance from the pneumatic weapons depends on the type of both the bullet and the weapon, as well as the properties of the target material. Specifically, the action of bullets fired from the piston pneumatic rifle remained stable whereas that of the bullets shot from the gas-balloon air pistol decreased as the gas was exhausted. The studies by the contact-diffusion method have demonstrated that the entrance bullet holes created by the shots from pneumatic weapons are surrounded by dispersed metal particles which makes it possible to estimate the shooting distance. Moreover, the bullets fired from the pneumatic weapons leave the muzzle face imprint on certain target materials.

  17. 144. VIEW OF EAST WALL OF CONTROL ROOM (214), LSB ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    144. VIEW OF EAST WALL OF CONTROL ROOM (214), LSB (BLDG. 751). PNEUMATIC SUPPLY PANEL ON LEFT; NITROGEN AND HELIUM PIPING AT TOP; PURGE PANEL AT BOTTOM OF PHOTOGRAPH. - Vandenberg Air Force Base, Space Launch Complex 3, Launch Pad 3 East, Napa & Alden Roads, Lompoc, Santa Barbara County, CA

  18. Flight evaluation of pneumatic forebody vortex control in post-stall flight

    NASA Technical Reports Server (NTRS)

    Walchli, Lawrence A.

    1994-01-01

    The following topics are discussed: (1) X-29 description; Vortex Flow Control (VFC) technology description; (3) X-29 VFC wind tunnel results (forebody only); (4) X-29 VFC wind tunnel results (full configuration yawing moment); (5) X-29 VFC wind tunnel results (full configuration C(sub n) with sideslip); (6) X-29VFC wind tunnel results (full configuration pitching moment); (7) VFC optimized nozzle details; (8) X-29 forebody nozzle configuration; (9) X-29 VFC system stored gas schematic; (10) X-29 VFC system stored gas installation; (11) VFC effectiveness at zero sideslip; (12) VFC effectiveness at 35 AOA with sideslip; (13) 'VFC Roll' at 40 AOA; (14) Effects of VFC on wing rock; (15) Integrated controls C(sub n) prediction; (16) Proposed F-15 with lateral control laws with active VFC; (17) Simulated F-15 roll performance with active VFC; (18) Simulated F-15 spin recovery with active VFC; (19) Test team restructuring; (20) testbed selection; (21) Simulation for risk reduction; (22) Benefits of high pressure system; and (23) Advanced weapon system integration.

  19. 49 CFR 574.6 - Identification mark.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) TIRE IDENTIFICATION AND RECORDKEEPING § 574.6... retreaded pneumatic tires, non-pneumatic tires or non-pneumatic tire assemblies shall apply in writing to... Street SW., Washington, DC 20590, identify itself as a tire manufacturer or retreader and furnish the...

  20. Novel intelligent real-time position tracking system using FPGA and fuzzy logic.

    PubMed

    Soares dos Santos, Marco P; Ferreira, J A F

    2014-03-01

    The main aim of this paper is to test if FPGAs are able to achieve better position tracking performance than software-based soft real-time platforms. For comparison purposes, the same controller design was implemented in these architectures. A Multi-state Fuzzy Logic controller (FLC) was implemented both in a Xilinx(®) Virtex-II FPGA (XC2v1000) and in a soft real-time platform NI CompactRIO(®)-9002. The same sampling time was used. The comparative tests were conducted using a servo-pneumatic actuation system. Steady-state errors lower than 4 μm were reached for an arbitrary vertical positioning of a 6.2 kg mass when the controller was embedded into the FPGA platform. Performance gains up to 16 times in the steady-state error, up to 27 times in the overshoot and up to 19.5 times in the settling time were achieved by using the FPGA-based controller over the software-based FLC controller. © 2013 ISA. Published by Elsevier Ltd. All rights reserved.

Top