Pneumatic gap sensor and method
Bagdal, Karl T.; King, Edward L.; Follstaedt, Donald W.
1992-01-01
An apparatus and method for monitoring and maintaining a predetermined width in the gap between a casting nozzle and a casting wheel, wherein the gap is monitored by means of at least one pneumatic gap sensor. The pneumatic gap sensor is mounted on the casting nozzle in proximity to the casting surface and is connected by means of a tube to a regulator and a transducer. The regulator provides a flow of gas through a restictor to the pneumatic gap sensor, and the transducer translates the changes in the gas pressure caused by the proximity of the casting wheel to the pneumatic gap sensor outlet into a signal intelligible to a control device. The relative positions of the casting nozzle and casting wheel can thereby be selectively adjusted to continually maintain a predetermined distance between their adjacent surfaces. The apparatus and method enables accurate monitoring of the actual casting gap in a simple and reliable manner resistant to the extreme temperatures and otherwise hostile casting environment.
Pneumatic gap sensor and method
Bagdal, K.T.; King, E.L.; Follstaedt, D.W.
1992-03-03
An apparatus and method for monitoring and maintaining a predetermined width in the gap between a casting nozzle and a casting wheel, wherein the gap is monitored by means of at least one pneumatic gap sensor. The pneumatic gap sensor is mounted on the casting nozzle in proximity to the casting surface and is connected by means of a tube to a regulator and a transducer. The regulator provides a flow of gas through a restictor to the pneumatic gap sensor, and the transducer translates the changes in the gas pressure caused by the proximity of the casting wheel to the pneumatic gap sensor outlet into a signal intelligible to a control device. The relative positions of the casting nozzle and casting wheel can thereby be selectively adjusted to continually maintain a predetermined distance between their adjacent surfaces. The apparatus and method enables accurate monitoring of the actual casting gap in a simple and reliable manner resistant to the extreme temperatures and otherwise hostile casting environment. 6 figs.
Embedded Triboelectric Active Sensors for Real-Time Pneumatic Monitoring.
Fu, Xian Peng; Bu, Tian Zhao; Xi, Feng Ben; Cheng, Ting Hai; Zhang, Chi; Wang, Zhong Lin
2017-09-20
Pneumatic monitoring sensors have great demands for power supply in cylinder systems. Here, we present an embedded sliding triboelectric nanogenerator (TENG) in air cylinder as active sensors for position and velocity monitoring. The embedded TENG is composed of a circular poly(tetrafluoroethylene) polymer and a triangular copper electrode. The working mechanism as triboelectric active sensors and electric output performance are systematically investigated. By integrating into the pneumatic system, the embedded triboelectric active sensors have been used for real-time air pressure/flow monitoring and energy storage. Air pressures are measured from 0.04 to 0.12 MPa at a step of 0.02 MPa with a sensitivity of 49.235 V/MPa, as well as airflow from 50 to 250 L/min at a step of 50 L/min with a sensitivity of 0.002 μA·min/L. This work has first demonstrated triboelectric active sensors for pneumatic monitoring and may promote the development of TENG in intelligent pneumatic system.
Variable reluctance proximity sensors for cryogenic valve position indication
NASA Technical Reports Server (NTRS)
Cloyd, R. A.
1982-01-01
A test was conducted to determine the performance of a variable reluctance proximity sensor system when installed in a space shuttle external tank vent/relief valve. The sensors were used as position indicators. The valve and sensors were cycled through a series of thermal transients; while the valve was being opened and closed pneumatically, the sensor's performance was being monitored. During these thermal transients, the vent valve was cooled ten times by liquid nitrogen and two times by liquid hydrogen. It was concluded that the sensors were acceptable replacements for the existing mechanical switches. However, the sensors need a mechanical override for the target similar to what is presently used with the mechanical switches. This override could insure contact between sensor and target and eliminate any problems of actuation gap growth caused by thermal gradients.
A Pneumatic Tactile Sensor for Co-Operative Robots
He, Rui; Yu, Jianjun; Zuo, Guoyu
2017-01-01
Tactile sensors of comprehensive functions are urgently needed for the advanced robot to co-exist and co-operate with human beings. Pneumatic tactile sensors based on air bladder possess some noticeable advantages for human-robot interaction application. In this paper, we construct a pneumatic tactile sensor and apply it on the fingertip of robot hand to realize the sensing of force, vibration and slippage via the change of the pressure of the air bladder, and we utilize the sensor to perceive the object’s features such as softness and roughness. The pneumatic tactile sensor has good linearity, repeatability and low hysteresis and both its size and sensing range can be customized by using different material as well as different thicknesses of the air bladder. It is also simple and cheap to fabricate. Therefore, the pneumatic tactile sensor is suitable for the application of co-operative robots and can be widely utilized to improve the performance of service robots. We can apply it to the fingertip of the robot to endow the robotic hand with the ability to co-operate with humans and handle the fragile objects because of the inherent compliance of the air bladder. PMID:29125565
Compensating for pneumatic distortion in pressure sensing devices
NASA Technical Reports Server (NTRS)
Whitmore, Stephen A.; Leondes, Cornelius T.
1990-01-01
A technique of compensating for pneumatic distortion in pressure sensing devices was developed and verified. This compensation allows conventional pressure sensing technology to obtain improved unsteady pressure measurements. Pressure distortion caused by frictional attenuation and pneumatic resonance within the sensing system makes obtaining unsteady pressure measurements by conventional sensors difficult. Most distortion occurs within the pneumatic tubing which transmits pressure impulses from the aircraft's surface to the measurement transducer. To avoid pneumatic distortion, experiment designers mount the pressure sensor at the surface of the aircraft, (called in-situ mounting). In-situ transducers cannot always fit in the available space and sometimes pneumatic tubing must be run from the aircraft's surface to the pressure transducer. A technique to measure unsteady pressure data using conventional pressure sensing technology was developed. A pneumatic distortion model is reduced to a low-order, state-variable model retaining most of the dynamic characteristics of the full model. The reduced-order model is coupled with results from minimum variance estimation theory to develop an algorithm to compensate for the effects of pneumatic distortion. Both postflight and real-time algorithms are developed and evaluated using simulated and flight data.
Development of a pneumatic tensioning device for gap measurement during total knee arthroplasty.
Kwak, Dai-Soon; Kong, Chae-Gwan; Han, Seung-Ho; Kim, Dong-Hyun; In, Yong
2012-09-01
Despite the importance of soft tissue balancing during total knee arthroplasty (TKA), all estimating techniques are dependent on a surgeon's manual distraction force or subjective feeling based on experience. We developed a new device for dynamic gap balancing, which can offer constant load to the gap between the femur and tibia, using pneumatic pressure during range of motion. To determine the amount of distraction force for the new device, 3 experienced surgeons' manual distraction force was measured using a conventional spreader. A new device called the consistent load pneumatic tensor was developed on the basis of the biomechanical tests. Reliability testing for the new device was performed using 5 cadaveric knees by the same surgeons. Intraclass correlation coefficients (ICCs) were calculated. The distraction force applied to the new pneumatic tensioning device was determined to be 150 N. The interobserver reliability was very good for the newly tested spreader device with ICCs between 0.828 and 0.881. The new pneumatic tensioning device can enable us to properly evaluate the soft tissue balance throughout the range of motion during TKA with acceptable reproducibility.
Distortion Of Pressure Signals In Pneumatic Tubes
NASA Technical Reports Server (NTRS)
Whitmore, Stephen A.; Gilyard, Glenn B.; Curry, Robert; Lindsey, William
1993-01-01
NASA technical memorandum describes experimental investigation of distorting effects of propagation of pressure signals along narrow pneumatic tubes from pressure-sensing orifices on surfaces of models or aircraft to pressure sensors distant from orifices. Pressure signals distorted principally by frictional damping along walls of tubes and by reflections at orifice and sensor ends.
Research on precise pneumatic-electric displacement sensor with large measurement range
NASA Astrophysics Data System (ADS)
Yin, Zhehao; Yuan, Yibao; Liu, Baoshuai
2017-10-01
This research mainly focuses on precise pneumatic-electric displacement sensor which has large measurement range. Under the high precision, measurement range can be expanded so that the need of high precision as well as large range can be satisfied in the field of machining inspection technology. This research was started by the analysis of pneumatic-measuring theory. Then, an gas circuit measuring system which is based on differential pressure was designed. This designed system can reach two aims: Firstly, to convert displacement signal into gas signal; Secondly, to reduce the measurement error which caused by pressure and environmental turbulence. Furthermore, in consideration of the high requirement for linearity, sensitivity and stability, the project studied the pneumatic-electric transducer which puts the SCX series pressure sensor as a key part. The main purpose of this pneumatic-electric transducer is to convert gas signal to suitable electrical signal. Lastly, a broken line subsection linearization circuit was designed, which can nonlinear correct the output characteristic curve so as to enlarge the linear measurement range. The final result could be briefly described like this: under the condition that measuring error is less than 1μm, measurement range could be extended to approximately 200μm which is much higher than the measurement range of traditional pneumatic measuring instrument. Meanwhile, it can reach higher exchangeability and stability in order to become more suitable to engineering application.
High-angle-of-attack pneumatic lag and upwash corrections for a hemispherical flow direction sensor
NASA Technical Reports Server (NTRS)
Whitmore, Stephen A.; Heeg, Jennifer; Larson, Terry J.; Ehernberger, L. J.; Hagen, Floyd W.; Deleo, Richard V.
1987-01-01
As part of the NASA F-14 high angle of attack flight test program, a nose mounted hemispherical flow direction sensor was calibrated against a fuselage mounted movable vane flow angle sensor. Significant discrepancies were found to exist in the angle of attack measurements. A two fold approach taken to resolve these discrepancies during subsonic flight is described. First, the sensing integrity of the isolated hemispherical sensor is established by wind tunnel data extending to an angle of attack of 60 deg. Second, two probable causes for the discrepancies, pneumatic lag and upwash, are examined. Methods of identifying and compensating for lag and upwash are presented. The wind tunnel data verify that the isolated hemispherical sensor is sufficiently accurate for static conditions with angles of attack up to 60 deg and angles of sideslip up to 30 deg. Analysis of flight data for two high angle of attack maneuvers establishes that pneumatic lag and upwash are highly correlated with the discrepancies between the hemispherical and vane type sensor measurements.
Experimental characterization of the effects of pneumatic tubing on unsteady pressure measurements
NASA Technical Reports Server (NTRS)
Whitmore, Stephen A.; Lindsey, William T.; Curry, Robert E.; Gilyard, Glenn B.
1990-01-01
Advances in aircraft control system designs have, with increasing frequency, required that air data be used as flight control feedback. This condition requires that these data be measured with accuracy and high fidelity. Most air data information is provided by pneumatic pressure measuring sensors. Typically unsteady pressure data provided by pneumatic sensing systems are distorted at high frequencies. The distortion is a result of the pressure being transmitted to the pressure sensor through a length of connective tubing. The pressure is distorted by frictional damping and wave reflection. As a result, air data provided all-flush, pneumatically sensed air data systems may not meet the frequency response requirements necessary for flight control augmentation. Both lab and flight test were performed at NASA-Ames to investigate the effects of this high frequency distortion in remotely located pressure measurement systems. Good qualitative agreement between lab and flight data are demonstrated. Results from these tests are used to describe the effects of pneumatic distortion in terms of a simple parametric model.
Soft Robots: Manipulation, Mobility, and Fast Actuation
NASA Astrophysics Data System (ADS)
Shepherd, Robert; Ilievski, Filip; Choi, Wonjae; Stokes, Adam; Morin, Stephen; Mazzeo, Aaron; Kramer, Rebecca; Majidi, Carmel; Wood, Rob; Whitesides, George
2012-02-01
Material innovation will be a key feature in the next generation of robots. A simple, pneumatically powered actuator composed of only soft-elastomers can perform the function of a complex arrangement of mechanical components and electric motors. This talk will focus on soft-lithography as a simple method to fabricate robots--composed of exclusively soft materials (elastomeric polymers). These robots have sophisticated capabilities: a gripper (with no electrical sensors) can manipulate delicate and irregularly shaped objects and a quadrupedal robot can walk to an obstacle (a gap smaller than its walking height) then shrink its body and squeeze through the gap using an undulatory gait. This talk will also introduce a new method of rapidly actuating soft robots. Using this new method, a robot can be caused to jump more than 30 times its height in under 200 milliseconds.
Multistage position-stabilized vibration isolation system for neutron interferometry
NASA Astrophysics Data System (ADS)
Arif, Muhammad; Brown, Dennis E.; Greene, Geoffrey L.; Clothier, R.; Littrell, K.
1994-10-01
A two stage, position stabilized vibration isolation system has been constructed and is now in operation at the Cold Neutron Research Facility of the National Institute of Standards and Technology, Gaithersburg, MD. The system employs pneumatic isolators with a multiple input/multiple output pneumatic servo system based upon pulse width modulation control loops. The first stage consists of a 40,000 kg reinforced concrete table supported by pneumatic isolators. A large environmentally isolated laboratory enclosure rests on the concrete table. The second stage consists of a 3000 kg granite optical table located within the enclosure and supported by another set of pneumatic isolators. The position of the two stages is monitored by proximity sensors and inclinometers with 12 degrees of freedom. The system controls 12 independent pneumatic airsprings. The signals from these sensors are fed into a personal computer based control system. The control system has maintained the position of the two stages to better than 1 micrometers in translation and 5 (mu) rad in orientation for a period of a few months. A description of the system and its characteristics is given.
Active Control of a Pneumatic Isolation System,
A pneumatically isolated test platform has been modified to provide active control to the local gravity vector. A combination of sensors , including... tiltmeters , angular accelerometers, seismometers, and a gyrocompass measure total platform motion between 0 and 100 Hz. Electrical-to-pressure
Estimating Fluctuating Pressures From Distorted Measurements
NASA Technical Reports Server (NTRS)
Whitmore, Stephen A.; Leondes, Cornelius T.
1994-01-01
Two algorithms extract estimates of time-dependent input (upstream) pressures from outputs of pressure sensors located at downstream ends of pneumatic tubes. Effect deconvolutions that account for distoring effects of tube upon pressure signal. Distortion of pressure measurements by pneumatic tubes also discussed in "Distortion of Pressure Signals in Pneumatic Tubes," (ARC-12868). Varying input pressure estimated from measured time-varying output pressure by one of two deconvolution algorithms that take account of measurement noise. Algorithms based on minimum-covariance (Kalman filtering) theory.
The Pneumatic Common: Learning in, with and from the Air
ERIC Educational Resources Information Center
Ford, Derek R.
2015-01-01
Air is an immersive substance that envelopes us and binds us together, yet it has dominantly been taken for granted and left out of educational and other theorizations. This article develops a conceptualization of the "pneumatic common" in order to address this gap. The specific intervention staged is within recent educational literature…
Inductance position sensor for pneumatic cylinder
NASA Astrophysics Data System (ADS)
Ripka, Pavel; Chirtsov, Andrey; Mirzaei, Mehran; Vyhnanek, Jan
2018-04-01
The position of the piston in pneumatic cylinder with aluminum wall can be measured by external inductance sensor without modifications of the aluminum piston and massive iron piston rod. For frequencies below 20 Hz the inductance is increasing with inserting rod due to the rod permeability. This mode has disadvantage of slow response to piston movement and also high temperature sensitivity. At the frequency of 45 Hz the inductance is position independent, as the permeability effect is compensated by the eddy current effect. At higher frequencies eddy current effects in the rod prevail, the inductance is decreasing with inserting rod. In this mode the sensitivity is smaller but the sensor response is fast and temperature stability is better. We show that FEM simulation of this sensor using measured material properties gives accurate results, which is important for the sensor optimization such as designing the winding geometry for the best linearity.
Extreme Mechanics in Soft Pneumatic Robots and Soft Microfluidic Electronics and Sensors
NASA Astrophysics Data System (ADS)
Majidi, Carmel
2012-02-01
In the near future, machines and robots will be completely soft, stretchable, impact resistance, and capable of adapting their shape and functionality to changes in mission and environment. Similar to biological tissue and soft-body organisms, these next-generation technologies will contain no rigid parts and instead be composed entirely of soft elastomers, gels, fluids, and other non-rigid matter. Using a combination of rapid prototyping tools, microfabrication methods, and emerging techniques in so-called ``soft lithography,'' scientists and engineers are currently introducing exciting new families of soft pneumatic robots, soft microfluidic sensors, and hyperelastic electronics that can be stretched to as much as 10x their natural length. Progress has been guided by an interdisciplinary collection of insights from chemistry, life sciences, robotics, microelectronics, and solid mechanics. In virtually every technology and application domain, mechanics and elasticity have a central role in governing functionality and design. Moreover, in contrast to conventional machines and electronics, soft pneumatic systems and microfluidics typically operate in the finite deformation regime, with materials stretching to several times their natural length. In this talk, I will review emerging paradigms in soft pneumatic robotics and soft microfluidic electronics and highlight modeling and design challenges that arise from the extreme mechanics of inflation, locomotion, sensor operation, and human interaction. I will also discuss perceived challenges and opportunities in a broad range of potential application, from medicine to wearable computing.
NASA Astrophysics Data System (ADS)
Chang, Ho; Lan, Chou-Wei; Guo, Jia-Bin
2011-12-01
This paper studies the influence of addition of 100 nm diameter nickel nano-particles on the friction properties of synthetic grease (Li base, VG100) in pneumatic cylinder. The friction force test of pneumatic cylinder equipment measures the frictional force between seal and cylinder bore in pneumatic cylinders. The lubricants with addition of nickel nano-particles were used for lubricating the contact interface between seal and cylinder bore. The friction force test equipment employ a load cell force sensor to measure the friction force between seals and cylinder bores. Results obtained from experimental tests are compared to determine the friction force between seals and cylinder bore in pneumatic cylinders. The study leads to the conclusion that the addition of nickel nano-particles to synthetic grease results in a decrease in friction force between seals and cylinder bores in pneumatic cylinder. This tribological behavior is closely related to the deposition of nano-particles on the rubbing surfaces
NASA Astrophysics Data System (ADS)
MacMillan, P. N.
1985-06-01
Recent improvements in rare earth magnets have made it possible to construct strong, lightweight, high horsepower dc motors. This has occasioned a reassessment of electromechanical actuators as alternatives to comparable pneumatic and hydraulic systems for use as flight control actuators for tactical missiles. A dynamic equivalent circuit model for the analysis of a small four pole brushless dc motor fed by a transistorized power conditioner utilizing high speed switching power transistors as final elements is presented. The influence of electronic commutation on instantaneous dynamic motor performance is particularly demonstrated and good correlation between computer simulation and typical experimentally obtained performance data is achieved. The model is implemented in CSMP language and features more accurate air gap flux representation over previous work. Hall effect sensor rotor position feedback is simulated. Both constant and variable air gap flux is modeled and the variable flux model treats the flux as a fundamental and one harmonic.
Electronically-Scanned Pressure Sensors
NASA Technical Reports Server (NTRS)
Coe, C. F.; Parra, G. T.; Kauffman, R. C.
1984-01-01
Sensors not pneumatically switched. Electronic pressure-transducer scanning system constructed in modular form. Pressure transducer modules and analog to digital converter module small enough to fit within cavities of average-sized wind-tunnel models. All switching done electronically. Temperature controlled environment maintained within sensor modules so accuracy maintained while ambient temperature varies.
An instrumented object for hand exercise and assessment using a pneumatic pressure sensor
NASA Astrophysics Data System (ADS)
Mohan, A.; Tharion, G.; Kumar, R. K.; Devasahayam, S. R.
2018-05-01
Measurement of grip force is important for both exercise training and assessment of the hand during physical rehabilitation. The standard method uses a grip dynamometer which measures the force between the fingers and opposing thumb. The primary limitation of the grip dynamometer is the restriction of measurement to cylindrical grasps. Any deformation of the hand due to muscular or skeletal disease makes the grip dynamometer difficult or impossible to use. An alternative to the grip dynamometer is a sealed pneumatic object that can be gripped by the hand. Measurement of the internal pressure in the object can be related to the grip force. In this paper, we analyze such a pneumatic pressure sensing object for hand grip assessment and also describe an easy fabrication of the grip sensor. The instrumented object presented in this paper is designed to assess both the maximal voluntary grip forces and continuous grip force to monitor control of hand function during exercise under instruction from a therapist. Potential uses of such a pneumatic pressure sensing object for hand grip are in physical rehabilitation of patients following paralysing illnesses like stroke and spinal cord injury.
NASA Technical Reports Server (NTRS)
Gilyard, G. B.; Belte, D.
1974-01-01
Magnitudes of lags in the pneumatic angle-of-attack and angle-of-sideslip sensor systems of the YF-12A airplane were determined for a variety of flight conditions by analyzing stability and control data. The three analysis techniques used are described. An apparent trend with Mach number for measurements from both of the differential-pressure sensors showed that the lag ranged from approximately 0.15 second at subsonic speed to 0.4 second at Mach 3. Because Mach number was closely related to altitude for the available flight data, the individual effects of Mach number and altitude on the lag could not be separated clearly. However, the results indicated the influence of factors other than simple pneumatic lag.
Optimal pressure regulation of the pneumatic ventricular assist device with bellows-type driver.
Lee, Jung Joo; Kim, Bum Soo; Choi, Jaesoon; Choi, Hyuk; Ahn, Chi Bum; Nam, Kyoung Won; Jeong, Gi Seok; Lim, Choon Hak; Son, Ho Sung; Sun, Kyung
2009-08-01
The bellows-type pneumatic ventricular assist device (VAD) generates pneumatic pressure with compression of bellows instead of using an air compressor. This VAD driver has a small volume that is suitable for portable devices. However, improper pneumatic pressure setup can not only cause a lack of adequate flow generation, but also cause durability problems. In this study, a pneumatic pressure regulation system for optimal operation of the bellows-type VAD has been developed. The optimal pneumatic pressure conditions according to various afterload conditions aiming for optimal flow rates were investigated, and an afterload estimation algorithm was developed. The developed regulation system, which consists of a pressure sensor and a two-way solenoid valve, estimates the current afterload and regulates the pneumatic pressure to the optimal point for the current afterload condition. Experiments were performed in a mock circulation system. The afterload estimation algorithm showed sufficient performance with the standard deviation of error, 8.8 mm Hg. The flow rate could be stably regulated with a developed system under various afterload conditions. The shortcoming of a bellows-type VAD could be handled with this simple pressure regulation system.
Electromagnetic Environmental Effects System Testing
2013-11-20
battery packs or air turbine power generators. The sensitivity of the entire instrumentation system should be taken into consideration from the sensor ...Electromagnetic Radiation to Ordnance (HERO) sensors , pneumatic switching, and those equipments associated with fiber optic technology. c. Test...Field probes to determine environment -Thermal heating sensors (e.g., FISO or Metricor systems) used to detect bridgewire heating induced by
Design of a Soft Robot with Multiple Motion Patterns Using Soft Pneumatic Actuators
NASA Astrophysics Data System (ADS)
Miao, Yu; Dong, Wei; Du, Zhijiang
2017-11-01
Soft robots are made of soft materials and have good flexibility and infinite degrees of freedom in theory. These properties enable soft robots to work in narrow space and adapt to external environment. In this paper, a 2-DOF soft pneumatic actuator is introduced, with two chambers symmetrically distributed on both sides and a jamming cylinder along the axis. Fibers are used to constrain the expansion of the soft actuator. Experiments are carried out to test the performance of the soft actuator, including bending and elongation characteristics. A soft robot is designed and fabricated by connecting four soft pneumatic actuators to a 3D-printed board. The soft robotic system is then established. The pneumatic circuit is built by pumps and solenoid valves. The control system is based on the control board Arduino Mega 2560. Relay modules are used to control valves and pressure sensors are used to measure pressure in the pneumatic circuit. Experiments are conducted to test the performance of the proposed soft robot.
Automatic inspection system for nuclear fuel pellets or rods
Miller, Jr., William H.; Sease, John D.; Hamel, William R.; Bradley, Ronnie A.
1978-01-01
An automatic inspection system is provided for determining surface defects on cylindrical objects such as nuclear fuel pellets or rods. The active element of the system is a compound ring having a plurality of pneumatic jet units directed into a central bore. These jet units are connected to provide multiple circuits, each circuit being provided with a pressure sensor. The outputs of the sensors are fed to a comparator circuit whereby a signal is generated when the difference of pressure between pneumatic circuits, caused by a defect, exceeds a pre-set amount. This signal may be used to divert the piece being inspected into a "reject" storage bin or the like.
Fiber optical sensors for aircraft applications
NASA Astrophysics Data System (ADS)
Pechstedt, Ralf D.
2014-09-01
In this paper selected fiber optical point sensors that are of potential interest for deployment in aircraft are discussed. The operating principles together with recent measurement results are described. Examples include a high-temperature combined pressure and temperature sensor for engine health, hydraulics and landing gear monitoring, an ultra-high sensitive pressure sensor for oil, pneumatic and fluid aero systems applications and a combined acceleration and temperature sensor for condition monitoring of rotating components.
Outflow monitoring of a pneumatic ventricular assist device using external pressure sensors.
Kang, Seong Min; Her, Keun; Choi, Seong Wook
2016-08-25
In this study, a new algorithm was developed for estimating the pump outflow of a pneumatic ventricular assist device (p-VAD). The pump outflow estimation algorithm was derived from the ideal gas equation and determined the change in blood-sac volume of a p-VAD using two external pressure sensors. Based on in vitro experiments, the algorithm was revised to consider the effects of structural compliance caused by volume changes in an implanted unit, an air driveline, and the pressure difference between the sensors and the implanted unit. In animal experiments, p-VADs were connected to the left ventricles and the descending aorta of three calves (70-100 kg). Their outflows were estimated using the new algorithm and compared to the results obtained using an ultrasonic blood flow meter (UBF) (TS-410, Transonic Systems Inc., Ithaca, NY, USA). The estimated and measured values had a Pearson's correlation coefficient of 0.864. The pressure sensors were installed at the external controller and connected to the air driveline on the same side as the external actuator, which made the sensors easy to manage.
Chiang, Mao-Hsiung; Lin, Hao-Ting
2011-01-01
This study aimed to develop a novel 3D parallel mechanism robot driven by three vertical-axial pneumatic actuators with a stereo vision system for path tracking control. The mechanical system and the control system are the primary novel parts for developing a 3D parallel mechanism robot. In the mechanical system, a 3D parallel mechanism robot contains three serial chains, a fixed base, a movable platform and a pneumatic servo system. The parallel mechanism are designed and analyzed first for realizing a 3D motion in the X-Y-Z coordinate system of the robot's end-effector. The inverse kinematics and the forward kinematics of the parallel mechanism robot are investigated by using the Denavit-Hartenberg notation (D-H notation) coordinate system. The pneumatic actuators in the three vertical motion axes are modeled. In the control system, the Fourier series-based adaptive sliding-mode controller with H(∞) tracking performance is used to design the path tracking controllers of the three vertical servo pneumatic actuators for realizing 3D path tracking control of the end-effector. Three optical linear scales are used to measure the position of the three pneumatic actuators. The 3D position of the end-effector is then calculated from the measuring position of the three pneumatic actuators by means of the kinematics. However, the calculated 3D position of the end-effector cannot consider the manufacturing and assembly tolerance of the joints and the parallel mechanism so that errors between the actual position and the calculated 3D position of the end-effector exist. In order to improve this situation, sensor collaboration is developed in this paper. A stereo vision system is used to collaborate with the three position sensors of the pneumatic actuators. The stereo vision system combining two CCD serves to measure the actual 3D position of the end-effector and calibrate the error between the actual and the calculated 3D position of the end-effector. Furthermore, to verify the feasibility of the proposed parallel mechanism robot driven by three vertical pneumatic servo actuators, a full-scale test rig of the proposed parallel mechanism pneumatic robot is set up. Thus, simulations and experiments for different complex 3D motion profiles of the robot end-effector can be successfully achieved. The desired, the actual and the calculated 3D position of the end-effector can be compared in the complex 3D motion control.
Chiang, Mao-Hsiung; Lin, Hao-Ting
2011-01-01
This study aimed to develop a novel 3D parallel mechanism robot driven by three vertical-axial pneumatic actuators with a stereo vision system for path tracking control. The mechanical system and the control system are the primary novel parts for developing a 3D parallel mechanism robot. In the mechanical system, a 3D parallel mechanism robot contains three serial chains, a fixed base, a movable platform and a pneumatic servo system. The parallel mechanism are designed and analyzed first for realizing a 3D motion in the X-Y-Z coordinate system of the robot’s end-effector. The inverse kinematics and the forward kinematics of the parallel mechanism robot are investigated by using the Denavit-Hartenberg notation (D-H notation) coordinate system. The pneumatic actuators in the three vertical motion axes are modeled. In the control system, the Fourier series-based adaptive sliding-mode controller with H∞ tracking performance is used to design the path tracking controllers of the three vertical servo pneumatic actuators for realizing 3D path tracking control of the end-effector. Three optical linear scales are used to measure the position of the three pneumatic actuators. The 3D position of the end-effector is then calculated from the measuring position of the three pneumatic actuators by means of the kinematics. However, the calculated 3D position of the end-effector cannot consider the manufacturing and assembly tolerance of the joints and the parallel mechanism so that errors between the actual position and the calculated 3D position of the end-effector exist. In order to improve this situation, sensor collaboration is developed in this paper. A stereo vision system is used to collaborate with the three position sensors of the pneumatic actuators. The stereo vision system combining two CCD serves to measure the actual 3D position of the end-effector and calibrate the error between the actual and the calculated 3D position of the end-effector. Furthermore, to verify the feasibility of the proposed parallel mechanism robot driven by three vertical pneumatic servo actuators, a full-scale test rig of the proposed parallel mechanism pneumatic robot is set up. Thus, simulations and experiments for different complex 3D motion profiles of the robot end-effector can be successfully achieved. The desired, the actual and the calculated 3D position of the end-effector can be compared in the complex 3D motion control. PMID:22247676
Su, Hao; Shang, Weijian; Li, Gang; Patel, Niravkumar; Fischer, Gregory S
2017-08-01
This paper presents a surgical master-slave teleoperation system for percutaneous interventional procedures under continuous magnetic resonance imaging (MRI) guidance. The slave robot consists of a piezoelectrically actuated 6-degree-of-freedom (DOF) robot for needle placement with an integrated fiber optic force sensor (1-DOF axial force measurement) using the Fabry-Perot interferometry (FPI) sensing principle; it is configured to operate inside the bore of the MRI scanner during imaging. By leveraging the advantages of pneumatic and piezoelectric actuation in force and position control respectively, we have designed a pneumatically actuated master robot (haptic device) with strain gauge based force sensing that is configured to operate the slave from within the scanner room during imaging. The slave robot follows the insertion motion of the haptic device while the haptic device displays the needle insertion force as measured by the FPI sensor. Image interference evaluation demonstrates that the telesurgery system presents a signal to noise ratio reduction of less than 17% and less than 1% geometric distortion during simultaneous robot motion and imaging. Teleoperated needle insertion and rotation experiments were performed to reach 10 targets in a soft tissue-mimicking phantom with 0.70 ± 0.35 mm Cartesian space error.
Shang, Weijian; Su, Hao; Li, Gang; Fischer, Gregory S.
2014-01-01
This paper presents a surgical master-slave tele-operation system for percutaneous interventional procedures under continuous magnetic resonance imaging (MRI) guidance. This system consists of a piezoelectrically actuated slave robot for needle placement with integrated fiber optic force sensor utilizing Fabry-Perot interferometry (FPI) sensing principle. The sensor flexure is optimized and embedded to the slave robot for measuring needle insertion force. A novel, compact opto-mechanical FPI sensor interface is integrated into an MRI robot control system. By leveraging the complementary features of pneumatic and piezoelectric actuation, a pneumatically actuated haptic master robot is also developed to render force associated with needle placement interventions to the clinician. An aluminum load cell is implemented and calibrated to close the impedance control loop of the master robot. A force-position control algorithm is developed to control the hybrid actuated system. Teleoperated needle insertion is demonstrated under live MR imaging, where the slave robot resides in the scanner bore and the user manipulates the master beside the patient outside the bore. Force and position tracking results of the master-slave robot are demonstrated to validate the tracking performance of the integrated system. It has a position tracking error of 0.318mm and sine wave force tracking error of 2.227N. PMID:25126446
Shang, Weijian; Su, Hao; Li, Gang; Fischer, Gregory S
2013-01-01
This paper presents a surgical master-slave tele-operation system for percutaneous interventional procedures under continuous magnetic resonance imaging (MRI) guidance. This system consists of a piezoelectrically actuated slave robot for needle placement with integrated fiber optic force sensor utilizing Fabry-Perot interferometry (FPI) sensing principle. The sensor flexure is optimized and embedded to the slave robot for measuring needle insertion force. A novel, compact opto-mechanical FPI sensor interface is integrated into an MRI robot control system. By leveraging the complementary features of pneumatic and piezoelectric actuation, a pneumatically actuated haptic master robot is also developed to render force associated with needle placement interventions to the clinician. An aluminum load cell is implemented and calibrated to close the impedance control loop of the master robot. A force-position control algorithm is developed to control the hybrid actuated system. Teleoperated needle insertion is demonstrated under live MR imaging, where the slave robot resides in the scanner bore and the user manipulates the master beside the patient outside the bore. Force and position tracking results of the master-slave robot are demonstrated to validate the tracking performance of the integrated system. It has a position tracking error of 0.318mm and sine wave force tracking error of 2.227N.
A high resolution pneumatic stepping actuator for harsh reactor environments
NASA Astrophysics Data System (ADS)
Tippetts, Thomas B.; Evans, Paul S.; Riffle, George K.
1993-01-01
A reactivity control actuator for a high-power density nuclear propulsion reactor must be installed in close proximity to the reactor core. The energy input from radiation to the actuator structure could exceed hundreds of W/cc unless low-cross section, low-absorptivity materials are chosen. Also, for post-test handling and subsequent storage, materials should not be used that are activated into long half-life isotopes. Pneumatic actuators can be constructed from various reactor-compatible materials, but conventional pneumatic piston actuators generally lack the stiffness required for high resolution reactivity control unless electrical position sensors and compensated electronic control systems are used. To overcome these limitations, a pneumatic actuator is under development that positions an output shaft in response to a series of pneumatic pulses, comprising a pneumatic analog of an electrical stepping motor. The pneumatic pulses are generated remotely, beyond the strong radiation environment, and transmitted to the actuator through tubing. The mechanically simple actuator uses a nutating gear harmonic drive to convert motion of small pistons directly to high-resolution angular motion of the output shaft. The digital nature of this actuator is suitable for various reactor control algorithms but is especially compatible with the three bean salad algorithm discussed by Ball et al. (1991).
Wearable Sweat Rate Sensors for Human Thermal Comfort Monitoring.
Sim, Jai Kyoung; Yoon, Sunghyun; Cho, Young-Ho
2018-01-19
We propose watch-type sweat rate sensors capable of automatic natural ventilation by integrating miniaturized thermo-pneumatic actuators, and experimentally verify their performances and applicability. Previous sensors using natural ventilation require manual ventilation process or high-power bulky thermo-pneumatic actuators to lift sweat rate detection chambers above skin for continuous measurement. The proposed watch-type sweat rate sensors reduce operation power by minimizing expansion fluid volume to 0.4 ml through heat circuit modeling. The proposed sensors reduce operation power to 12.8% and weight to 47.6% compared to previous portable sensors, operating for 4 hours at 6 V batteries. Human experiment for thermal comfort monitoring is performed by using the proposed sensors having sensitivity of 0.039 (pF/s)/(g/m 2 h) and linearity of 97.9% in human sweat rate range. Average sweat rate difference for each thermal status measured in three subjects shows (32.06 ± 27.19) g/m 2 h in thermal statuses including 'comfortable', 'slightly warm', 'warm', and 'hot'. The proposed sensors thereby can discriminate and compare four stages of thermal status. Sweat rate measurement error of the proposed sensors is less than 10% under air velocity of 1.5 m/s corresponding to human walking speed. The proposed sensors are applicable for wearable and portable use, having potentials for daily thermal comfort monitoring applications.
NASA Technical Reports Server (NTRS)
Whitmore, Stephen A.; Haering, Edward A., Jr.; Ehernberger, L. J.
1996-01-01
In-flight measurements of the SR-71 near-field sonic boom were obtained by an F-16XL airplane at flightpath separation distances from 40 to 740 ft. Twenty-two signatures were obtained from Mach 1.60 to Mach 1.84 and altitudes from 47,600 to 49,150 ft. The shock wave signatures were measured by the total and static sensors on the F-16XL noseboo. These near-field signature measurements were distorted by pneumatic attenuation in the pitot-static sensors and accounting for their effects using optimal deconvolution. Measurement system magnitude and phase characteristics were determined from ground-based step-response tests and extrapolated to flight conditions using analytical models. Deconvolution was implemented using Fourier transform methods. Comparisons of the shock wave signatures reconstructed from the total and static pressure data are presented. The good agreement achieved gives confidence of the quality of the reconstruction analysis. although originally developed to reconstruct the sonic boom signatures from SR-71 sonic boom flight tests, the methods presented here generally apply to other types of highly attenuated or distorted pneumatic measurements.
Soft pneumatic grippers embedded with stretchable electroadhesion
NASA Astrophysics Data System (ADS)
Guo, J.; Elgeneidy, K.; Xiang, C.; Lohse, N.; Justham, L.; Rossiter, J.
2018-05-01
Current soft pneumatic grippers cannot robustly grasp flat materials and flexible objects on curved surfaces without distorting them. Current electroadhesive grippers, on the other hand, are difficult to actively deform to complex shapes to pick up free-form surfaces or objects. An easy-to-implement PneuEA gripper is proposed by the integration of an electroadhesive gripper and a two-fingered soft pneumatic gripper. The electroadhesive gripper was fabricated by segmenting a soft conductive silicon sheet into a two-part electrode design and embedding it in a soft dielectric elastomer. The two-fingered soft pneumatic gripper was manufactured using a standard soft lithography approach. This novel integration has combined the benefits of both the electroadhesive and soft pneumatic grippers. As a result, the proposed PneuEA gripper was not only able to pick-and-place flat and flexible materials such as a porous cloth but also delicate objects such as a light bulb. By combining two soft touch sensors with the electroadhesive, an intelligent and shape-adaptive PneuEA material handling system has been developed. This work is expected to widen the applications of both soft gripper and electroadhesion technologies.
A New Type of Motor: Pneumatic Step Motor
Stoianovici, Dan; Patriciu, Alexandru; Petrisor, Doru; Mazilu, Dumitru; Kavoussi, Louis
2011-01-01
This paper presents a new type of pneumatic motor, a pneumatic step motor (PneuStep). Directional rotary motion of discrete displacement is achieved by sequentially pressurizing the three ports of the motor. Pulsed pressure waves are generated by a remote pneumatic distributor. The motor assembly includes a motor, gearhead, and incremental position encoder in a compact, central bore construction. A special electronic driver is used to control the new motor with electric stepper indexers and standard motion control cards. The motor accepts open-loop step operation as well as closed-loop control with position feedback from the enclosed sensor. A special control feature is implemented to adapt classic control algorithms to the new motor, and is experimentally validated. The speed performance of the motor degrades with the length of the pneumatic hoses between the distributor and motor. Experimental results are presented to reveal this behavior and set the expectation level. Nevertheless, the stepper achieves easily controllable precise motion unlike other pneumatic motors. The motor was designed to be compatible with magnetic resonance medical imaging equipment, for actuating an image-guided intervention robot, for medical applications. For this reason, the motors were entirely made of nonmagnetic and dielectric materials such as plastics, ceramics, and rubbers. Encoding was performed with fiber optics, so that the motors are electricity free, exclusively using pressure and light. PneuStep is readily applicable to other pneumatic or hydraulic precision-motion applications. PMID:21528106
Lin, Hao-Ting
2017-06-04
This project aims to develop a novel large stroke asymmetric pneumatic servo system of a hardware-in-the-loop for path tracking control under variable loads based on the MATLAB Simulink real-time system. High pressure compressed air provided by the air compressor is utilized for the pneumatic proportional servo valve to drive the large stroke asymmetric rod-less pneumatic actuator. Due to the pressure differences between two chambers, the pneumatic actuator will operate. The highly nonlinear mathematical models of the large stroke asymmetric pneumatic system were analyzed and developed. The functional approximation technique based on the sliding mode controller (FASC) is developed as a controller to solve the uncertain time-varying nonlinear system. The MATLAB Simulink real-time system was a main control unit of a hardware-in-the-loop system proposed to establish driver blocks for analog and digital I/O, a linear encoder, a CPU and a large stroke asymmetric pneumatic rod-less system. By the position sensor, the position signals of the cylinder will be measured immediately. The measured signals will be viewed as the feedback signals of the pneumatic servo system for the study of real-time positioning control and path tracking control. Finally, real-time control of a large stroke asymmetric pneumatic servo system with measuring system, a large stroke asymmetric pneumatic servo system, data acquisition system and the control strategy software will be implemented. Thus, upgrading the high position precision and the trajectory tracking performance of the large stroke asymmetric pneumatic servo system will be realized to promote the high position precision and path tracking capability. Experimental results show that fifth order paths in various strokes and the sine wave path are successfully implemented in the test rig. Also, results of variable loads under the different angle were implemented experimentally.
Lin, Hao-Ting
2017-01-01
This project aims to develop a novel large stroke asymmetric pneumatic servo system of a hardware-in-the-loop for path tracking control under variable loads based on the MATLAB Simulink real-time system. High pressure compressed air provided by the air compressor is utilized for the pneumatic proportional servo valve to drive the large stroke asymmetric rod-less pneumatic actuator. Due to the pressure differences between two chambers, the pneumatic actuator will operate. The highly nonlinear mathematical models of the large stroke asymmetric pneumatic system were analyzed and developed. The functional approximation technique based on the sliding mode controller (FASC) is developed as a controller to solve the uncertain time-varying nonlinear system. The MATLAB Simulink real-time system was a main control unit of a hardware-in-the-loop system proposed to establish driver blocks for analog and digital I/O, a linear encoder, a CPU and a large stroke asymmetric pneumatic rod-less system. By the position sensor, the position signals of the cylinder will be measured immediately. The measured signals will be viewed as the feedback signals of the pneumatic servo system for the study of real-time positioning control and path tracking control. Finally, real-time control of a large stroke asymmetric pneumatic servo system with measuring system, a large stroke asymmetric pneumatic servo system, data acquisition system and the control strategy software will be implemented. Thus, upgrading the high position precision and the trajectory tracking performance of the large stroke asymmetric pneumatic servo system will be realized to promote the high position precision and path tracking capability. Experimental results show that fifth order paths in various strokes and the sine wave path are successfully implemented in the test rig. Also, results of variable loads under the different angle were implemented experimentally. PMID:28587220
Propulsion System with Pneumatic Artificial Muscles for Powering Ankle-Foot Orthosis
NASA Astrophysics Data System (ADS)
Veneva, Ivanka; Vanderborght, Bram; Lefeber, Dirk; Cherelle, Pierre
2013-12-01
The aim of this paper is to present the design of device for control of new propulsion system with pneumatic artificial muscles. The propulsion system can be used for ankle joint articulation, for assisting and rehabilitation in cases of injured ankle-foot complex, stroke patients or elderly with functional weakness. Proposed device for control is composed by microcontroller, generator for muscles contractions and sensor system. The microcontroller receives the control signals from sensors and modulates ankle joint flex- ion and extension during human motion. The local joint control with a PID (Proportional-Integral Derivative) position feedback directly calculates desired pressure levels and dictates the necessary contractions. The main goal is to achieve an adaptation of the system and provide the necessary joint torque using position control with feedback.
CSMP (Continuous System Modeling Program) modeling of brushless DC motors
NASA Astrophysics Data System (ADS)
Thomas, S. M.
1984-09-01
Recent improvements in rare earth magnets have made it possible to construct strong, lightweight, high horsepower DC motors. This has occasioned a reassessment of electromechanical actuators as alternatives to comparable pneumatic and hydraulic systems for use in flight control actuators for tactical missiles. This thesis develops a low-order mathematical model for the simulation and analysis of brushless DC motor performance. This model is implemented in CSMP language. It is used to predict such motor performance curves as speed, current and power versus torque. Electronic commutation based on Hall effect sensor positional feedback is simulated. Steady state motor behavior is studied under both constant and variable air gap flux conditions. The variable flux takes two different forms. In the first case, the flux is varied as a simple sinusoid. In the second case, the flux is varied as the sum of a sinusoid and one of its harmonics.
Calculation Of Pneumatic Attenuation In Pressure Sensors
NASA Technical Reports Server (NTRS)
Whitmore, Stephen A.
1991-01-01
Errors caused by attenuation of air-pressure waves in narrow tubes calculated by method based on fundamental equations of flow. Changes in ambient pressure transmitted along narrow tube to sensor. Attenuation of high-frequency components of pressure wave calculated from wave equation derived from Navier-Stokes equations of viscous flow in tube. Developed to understand and compensate for frictional attenuation in narrow tubes used to connect aircraft pressure sensors with pressure taps on affected surfaces.
Surgical bedside master console for neurosurgical robotic system.
Arata, Jumpei; Kenmotsu, Hajime; Takagi, Motoki; Hori, Tatsuya; Miyagi, Takahiro; Fujimoto, Hideo; Kajita, Yasukazu; Hayashi, Yuichiro; Chinzei, Kiyoyuki; Hashizume, Makoto
2013-01-01
We are currently developing a neurosurgical robotic system that facilitates access to residual tumors and improves brain tumor removal surgical outcomes. The system combines conventional and robotic surgery allowing for a quick conversion between the procedures. This concept requires a new master console that can be positioned at the surgical bedside and be sterilized. The master console was developed using new technologies, such as a parallel mechanism and pneumatic sensors. The parallel mechanism is a purely passive 5-DOF (degrees of freedom) joystick based on the author's haptic research. The parallel mechanism enables motion input of conventional brain tumor removal surgery with a compact, intuitive interface that can be used in a conventional surgical environment. In addition, the pneumatic sensors implemented on the mechanism provide an intuitive interface and electrically isolate the tool parts from the mechanism so they can be easily sterilized. The 5-DOF parallel mechanism is compact (17 cm width, 19cm depth, and 15cm height), provides a 505,050 mm and 90° workspace and is highly backdrivable (0.27N of resistance force representing the surgical motion). The evaluation tests revealed that the pneumatic sensors can properly measure the suction strength, grasping force, and hand contact. In addition, an installability test showed that the master console can be used in a conventional surgical environment. The proposed master console design was shown to be feasible for operative neurosurgery based on comprehensive testing. This master console is currently being tested for master-slave control with a surgical robotic system.
NASA Technical Reports Server (NTRS)
Whitmore, Stephen A.; Moes, Timothy R.
1991-01-01
The accuracy of a nonintrusive high angle-of-attack flush airdata sensing (HI-FADS) system was verified for quasi-steady flight conditions up to 55 deg angle of attack during the F-18 High Alpha Research Vehicle (HARV) Program. The system is a matrix of nine pressure ports arranged in annular rings on the aircraft nose. The complete airdata set is estimated using nonlinear regression. Satisfactory frequency response was verified to the system Nyquist frequency (12.5 Hz). The effects of acoustical distortions within the individual pressure sensors of the nonintrusive pressure matrix on overall system performance are addressed. To quantify these effects, a frequency-response model describing the dynamics of acoustical distortion is developed and simple design criteria are derived. The model adjusts measured HI-FADS pressure data for the acoustical distortion and quantifies the effects of internal sensor geometries on system performance. Analysis results indicate that sensor frequency response characteristics very greatly with altitude, thus it is difficult to select satisfactory sensor geometry for all altitudes. The solution used presample filtering to eliminate resonance effects, and short pneumatic tubing sections to reduce lag effects. Without presample signal conditioning the system designer must use the pneumatic transmission line to attenuate the resonances and accept the resulting altitude variability.
Computation and Pre-Parametric Design
1988-09-01
dynamic systems. Instruments, sensors , and actuators fall into this class of devices, and examples include pressure gages, pneumatic cylinders...novel tiltmeter . The design was based on an abstraction of the problem and clever use of analogy. [Maher87] proposes that certain design synthesis...temperature differences. This principle is exploited in order to build robust, inexpensive and accurate temperature sensors . The principle can also be used
Micromachined Electron-Tunneling Infrared Detectors
NASA Technical Reports Server (NTRS)
Kenny, Thomas W.; Kaiser, William J.; Waltman, Stephen B.
1993-01-01
Pneumatic/thermal infrared detectors based partly on Golay-cell concept, but smaller and less fragile. Include containers filled with air or other gas trapped behind diaphragms. Infrared radiation heats sensors, causing gas to expand. Resulting deflections of diaphragms measured by displacement sensors based on principle of electron-tunneling transducers of scanning tunneling microscopes. Exceed sensitivity of all other miniature, uncooled infrared sensors presently available. Expected to include low consumption of power, broadband sensitivity, room-temperature operation, and invulnerability to ionizing radiation.
Kim, Hyung Jin; Seo, Yeong Ho; Kim, Byeong Hee
2017-01-01
In this study, a non-contact type intraocular pressure (IOP) measuring system using reflected pneumatic pressure is proposed to overcome the disadvantages of existing measurement systems. A ring-type nozzle, a key component in the proposed system, is designed via computational fluid analysis. It predicts the reflected pneumatic pressure based on the nozzle exit angle and inner and outer diameters of the nozzle, which are 30°, 7 mm, and 9 mm, respectively. Performance evaluation is conducted using artificial eyes fabricated using polydimethylsiloxane with the specifications of human eyes. The IOP of the fabricated artificial eyes is adjusted to 10, 30, and 50 mm Hg, and the reflected pneumatic pressure is measured as a function of the distance between the ring-type nozzle and artificial eye. The measured reflected pneumatic pressure is high when the measurement distance is short and eye pressure is low. The cornea of an artificial eye is significantly deformed at a low IOP, and the applied pneumatic pressure is more concentrated in front of the ring-type nozzle because of the deformed cornea. Thus, the reflected pneumatic pressure at a low IOP has more inflows into the pressure sensor inserted inside the nozzle. The sensitivity of the output based on the IOP at measurement distances between 3-5 mm is -0.0027, -0.0022, -0.0018, -0.0015, and -0.0012. Sensitivity decreases as the measurement distance increases. In addition, the reflected pneumatic pressure owing to the misalignment at the measurement distances of 3-5 mm is not affected within a range of 0.5 mm. Therefore, the measurement range is acceptable up to a 1 mm diameter from the center of an artificial eye. However, the accuracy gradually decreases as the reflected pneumatic pressure from a misalignment of 1 mm or more decreases by 26% or more.
Kim, Hyung Jin; Seo, Yeong Ho
2017-01-01
In this study, a non-contact type intraocular pressure (IOP) measuring system using reflected pneumatic pressure is proposed to overcome the disadvantages of existing measurement systems. A ring-type nozzle, a key component in the proposed system, is designed via computational fluid analysis. It predicts the reflected pneumatic pressure based on the nozzle exit angle and inner and outer diameters of the nozzle, which are 30°, 7 mm, and 9 mm, respectively. Performance evaluation is conducted using artificial eyes fabricated using polydimethylsiloxane with the specifications of human eyes. The IOP of the fabricated artificial eyes is adjusted to 10, 30, and 50 mm Hg, and the reflected pneumatic pressure is measured as a function of the distance between the ring-type nozzle and artificial eye. The measured reflected pneumatic pressure is high when the measurement distance is short and eye pressure is low. The cornea of an artificial eye is significantly deformed at a low IOP, and the applied pneumatic pressure is more concentrated in front of the ring-type nozzle because of the deformed cornea. Thus, the reflected pneumatic pressure at a low IOP has more inflows into the pressure sensor inserted inside the nozzle. The sensitivity of the output based on the IOP at measurement distances between 3–5 mm is -0.0027, -0.0022, -0.0018, -0.0015, and -0.0012. Sensitivity decreases as the measurement distance increases. In addition, the reflected pneumatic pressure owing to the misalignment at the measurement distances of 3–5 mm is not affected within a range of 0.5 mm. Therefore, the measurement range is acceptable up to a 1 mm diameter from the center of an artificial eye. However, the accuracy gradually decreases as the reflected pneumatic pressure from a misalignment of 1 mm or more decreases by 26% or more. PMID:29216189
RaPToRS Sample Delivery System
NASA Astrophysics Data System (ADS)
Henchen, Robert; Shibata, Kye; Krieger, Michael; Pogozelski, Edward; Padalino, Stephen; Glebov, Vladimir; Sangster, Craig
2010-11-01
At various labs (NIF, LLE, NRL), activated material samples are used to measure reaction properties. The Rapid Pneumatic Transport of Radioactive Samples (RaPToRS) system quickly and safely moves these radioactive samples through a closed PVC tube via airflow. The carrier travels from the reaction chamber to the control and analysis station, pneumatically braking at the outlet. A reversible multiplexer routes samples from various locations near the shot chamber to the analysis station. Also, the multiplexer allows users to remotely load unactivated samples without manually approaching the reaction chamber. All elements of the system (pneumatic drivers, flow control valves, optical position sensors, multiplexers, Geiger counters, and release gates at the analysis station) can be controlled manually or automatically using a custom LabVIEW interface. A prototype is currently operating at NRL in Washington DC. Prospective facilities for Raptors systems include LLE and NIF.
System Measures Pressures Aboard A Compressor Rotor
NASA Technical Reports Server (NTRS)
Freedman, Robert J.; Senyitko, Richard G.; Blumenthal, Philip Z.
1994-01-01
Rotating pressure-measuring instrumentation includes on-board calibration standard. Computer-controlled, multichannel instrumentation system acquires pressure measurements from sensors mounted in 1.52-m-diameter rotor of compressor. Includes 5 miniature, electronically scanned pressure (ESP) modules, each containing 48 piezoresistive pressure sensors, pneumatic calibration valve, and electronic circuits for addressing and amplifying output of each sensor. Modules mounted on centerline of rotor, on instrumentation tower located inside nose cone of rotor. Subsystem designed to convert analog signal to distinct frequency without significantly affecting accuracy.
Assessment of Pneumatic Controller Emission Measurements ...
Oil and Natural Gas (ONG) production facilities have the potential to emit greenhouse gases such as methane (CH4) and other hydrocarbons (HCs) to the atmosphere. ONG production sites have multiple emission sources including storage tank venting, enclosed combustion devices, engine exhaust, pneumatic controllers and uncontrolled leaks. Accounting for up to 37.8 percent of CH4 emissions, pneumatic controllers are one of the most significant sources of CH4 in ONG production field operations. Recent measurement studies used the only commercially-available high volume sampling (HVS) technology (Bacharach Hi Flow Sampler, Bacharach, Inc., New Kensington, PA) to quantify CH4 emission rates of pneumatic devices on ONG production pads and compare to inventory estimates. Other studies indicate that this HVS may malfunction, causing underestimates of emissions in certain scenarios encountered in ONG production and should not be used for some sources such as heavy emissions from condensate storage tanks. The HVS malfunction can occur on relatively large emissions, where the measured leak concentrations exceed 5%, and is ascribed to a sensor transition failure in the instrument. The HVS malfunction is believed to be exacerbated by several factors (large emission rates, amount of non-CH4 HCs in the emission stream, non-optimal HVS calibration frequency, firmware, and emission measurement coupling geometries). The degree to which HVS measurements of emissions from pneumatic co
Development of multichannel soft tactile sensors having fingerprint structure.
Tsutsui, H; Murashima, Y; Honma, N; Kobayashi, K
2014-01-01
It is possible to accurately recognize the shape of an object or to grip it by setting soft tactile sensors on a robot's hands. We studied a multichannel soft tactile sensor as an artificial hand and evaluated the pressure's response performance from several directions and the slipping and sliding responses. The tactile sensor consisted of multiple pneumatic sensors and a soft cap with a fingerprint structure that was made of silicone gum and was separated from multiple spaces. Evaluation tests showed that the multiple soft tactile sensors estimate both an object's contact force and its contact location. Our tactile sensor also measured the object's roughness by the slide on surface texture.
NASA Astrophysics Data System (ADS)
Akagi, Tetsuya; Dohta, Shujiro; Matsushita, Hisashi; Fukuhara, Akimasa
The purpose of this study is to develop a lightweight and intelligent soft actuator which can be safely attached to the human body. A novel flexible pneumatic cylinder that can be used even if it is deformed by external force had been proposed. The cylinder can realize both pushing and pulling motions even if the cylinder bends. In this paper, a flexible pneumatic cylinder with a built-in flexible linear encoder is proposed and tested. The encoder can detect the cylinder displacement even if the cylinder bends. In the next step, to realize an intelligent flexible cylinder, it is essential to recognize the angle of deflection of the cylinder to estimate the direction of the external force. Therefore, a flexible bending sensor that can measure the directional angle by attaching it to the end of the cylinder is also proposed and tested. The tested bending sensor also consists of four inexpensive photo-reflectors set on the circumferential surface to the cylinder tube every 90 degrees from the center of the tube. By measuring the distance between the photo reflector and the surface of the tube at each point, the bending directional angle of the cylinder can be obtained. A low cost measuring system using a micro-computer incorporating a programmed Up/Down counter to measure the displacement of the cylinder is also developed. As a result, it was confirmed that the measuring accuracy of the bending directional angle was good, less than 0.7 degrees as a standard deviation.
Portable Dextrous Force Feedback Master for robot telemanipulation (PDMFF)
NASA Technical Reports Server (NTRS)
Burdea, Grigore C.; Speeter, Thomas H.
1989-01-01
A major drawback of open loop masters is a lack of force feedback, limiting their ability to perform complex tasks such as assembly and repair. Researchers present a simple dextrous force feedback master for computer assisted telemanipulation. The device is compact, portable and can be held in the operator hand, without the need for a special joystick or console. The system is capable of both position feed forward and force feedback, using electronic position sensors and a pneumatic micro-actuator. The level of forces exercised by the pneumatic actuator is such that near rigidity may be attained. Experimental results showing good system linearity and small time lag are given.
Adding Some Gas Can Completely Change How an Object in a Liquid-Filled Housing Responds to Vibration
NASA Astrophysics Data System (ADS)
Torczynski, J. R.; O'Hern, T. J.; Clausen, J. R.
2015-11-01
Adding a little gas can completely change the motion of an object in a liquid-filled housing during vibration. A common system exhibiting this behavior is a spring-supported piston in a liquid-filled cylinder, where the gaps between them are narrow and depend on the piston position. When gas is absent, the piston's vibrational response is highly overdamped due to forcing viscous liquid through narrow gaps. When a small amount of gas is added, Bjerknes forces cause some of the gas to migrate below the piston. The resulting two gas regions form a pneumatic spring that enables the liquid to move with the piston, with the result that very little liquid is forced through the narrow gaps. This ``Couette mode'' has low damping and thus has a strong resonance near the frequency given by the pneumatic spring constant and the piston mass. At this frequency, the piston response is large, and the nonlinearity from the gap geometry produces a net force on the piston. This ``rectified'' force can be many times the piston's weight and can cause the piston to compress its supporting spring. Sandia National Laboratories is a multi-program laboratory managed and operated by Sandia Corporation, a wholly owned subsidiary of Lockheed Martin Corporation, for the U.S. Department of Energy's National Nuclear Security Administration under contract DE-AC04-94AL85000.
NASA Technical Reports Server (NTRS)
1997-01-01
Through a Small Business Innovation Research (SBIR) contract from Kennedy Space Center, General Pneumatics Corporation's Western Research Center satisfied a NASA need for a non-clogging Joule-Thomson cryostat to provide very low temperature cooling for various sensors. This NASA-supported cryostat development played a key part in the development of more portable high-purity geranium gamma-ray detectors. Such are necessary to discern between the radionuclides in medical, fuel, weapon, and waste materials. The outcome of the SBIR project is a cryostat that can cool gamma-ray detectors, without vibration, using compressed gas that can be stored compactly and indefinitely in a standby mode. General Pneumatics also produces custom J-T cryostats for other government, commercial and medical applications.
Shepherd, Robert F.; Ilievski, Filip; Choi, Wonjae; Morin, Stephen A.; Stokes, Adam A.; Mazzeo, Aaron D.; Chen, Xin; Wang, Michael; Whitesides, George M.
2011-01-01
This manuscript describes a unique class of locomotive robot: A soft robot, composed exclusively of soft materials (elastomeric polymers), which is inspired by animals (e.g., squid, starfish, worms) that do not have hard internal skeletons. Soft lithography was used to fabricate a pneumatically actuated robot capable of sophisticated locomotion (e.g., fluid movement of limbs and multiple gaits). This robot is quadrupedal; it uses no sensors, only five actuators, and a simple pneumatic valving system that operates at low pressures (< 10 psi). A combination of crawling and undulation gaits allowed this robot to navigate a difficult obstacle. This demonstration illustrates an advantage of soft robotics: They are systems in which simple types of actuation produce complex motion. PMID:22123978
Alici, Gursel; Canty, Taylor; Mutlu, Rahim; Hu, Weiping; Sencadas, Vitor
2018-02-01
In this article, we have established an analytical model to estimate the quasi-static bending displacement (i.e., angle) of the pneumatic actuators made of two different elastomeric silicones (Elastosil M4601 with a bulk modulus of elasticity of 262 kPa and Translucent Soft silicone with a bulk modulus of elasticity of 48 kPa-both experimentally determined) and of discrete chambers, partially separated from each other with a gap in between the chambers to increase the magnitude of their bending angle. The numerical bending angle results from the proposed gray-box model, and the corresponding experimental results match well that the model is accurate enough to predict the bending behavior of this class of pneumatic soft actuators. Further, by using the experimental bending angle results and blocking force results, the effective modulus of elasticity of the actuators is estimated from a blocking force model. The numerical and experimental results presented show that the bending angle and blocking force models are valid for this class of pneumatic actuators. Another contribution of this study is to incorporate a bistable flexible thin metal typified by a tape measure into the topology of the actuators to prevent the deflection of the actuators under their own weight when operating in the vertical plane.
Li, Jian; Kong, Ming; Xu, Chuanlong; Wang, Shimin; Fan, Ying
2015-12-10
The online and continuous measurement of velocity, concentration and mass flow rate of pneumatically conveyed solid particles for the high-efficiency utilization of energy and raw materials has become increasingly significant. In this paper, an integrated instrumentation system for the velocity, concentration and mass flow rate measurement of dense phase pneumatically conveyed solid particles based on electrostatic and capacitance sensorsis developed. The electrostatic sensors are used for particle mean velocity measurement in combination with the cross-correlation technique, while the capacitance sensor with helical surface-plate electrodes, which has relatively homogeneous sensitivity distribution, is employed for the measurement of particle concentration and its capacitance is measured by an electrostatic-immune AC-based circuit. The solid mass flow rate can be further calculated from the measured velocity and concentration. The developed instrumentation system for velocity and concentration measurement is verified and calibrated on a pulley rig and through static experiments, respectively. Finally the system is evaluated with glass beads on a gravity-fed rig. The experimental results demonstrate that the system is capable of the accurate solid mass flow rate measurement, and the relative error is within -3%-8% for glass bead mass flow rates ranging from 0.13 kg/s to 0.9 kg/s.
The Structure, Design, and Closed-Loop Motion Control of a Differential Drive Soft Robot.
Wu, Pang; Jiangbei, Wang; Yanqiong, Fei
2018-02-01
This article presents the structure, design, and motion control of an inchworm inspired pneumatic soft robot, which can perform differential movement. This robot mainly consists of two columns of pneumatic multi-airbags (actuators), one sensor, one baseboard, front feet, and rear feet. According to the different inflation time of left and right actuators, the robot can perform both linear and turning movements. The actuators of this robot are composed of multiple airbags, and the design of the airbags is analyzed. To deal with the nonlinear performance of the soft robot, we use radial basis function neural networks to train the turning ability of this robot on three different surfaces and create a mathematical model among coefficient of friction, deflection angle, and inflation time. Then, we establish the closed-loop automatic control model using three-axis electronic compass sensor. Finally, the automatic control model is verified by linear and turning movement experiments. According to the experiment, the robot can finish the linear and turning movements under the closed-loop control system.
Pneumatic Proboscis Heat-Flow Probe
NASA Technical Reports Server (NTRS)
Zacny, Kris; Hedlund, Magnus; Mumm, Eric; Shasho, Jeffrey; Chu, Philip; Kumar, Nishant
2013-01-01
Heat flow is a fundamental property of a planet, and provides significant constraints on the abundance of radiogenic isotopes, the thermal evolution and differentiation history, and the mechanical properties of the lithosphere. Heat-flow measurements are also essential in achieving at least four of the goals set out by the National Research Council for future lunar exploration. The heat-flow probe therefore directly addresses the goal of the Lunar Geophysical Network, which is to understand the interior structure and composition of the Moon. A key challenge for heat flow measurement is to install thermal sensors to the depths approximately equal to 3 m that are not influenced by the diurnal, annual, and longer-term fluctuations of the surface thermal environment. In addition, once deployed, the heat flow probe should cause little disturbance to the thermal regime of the surrounding regolith. A heat-flow probe system was developed that has two novel features: (1) it utilizes a pneumatic (gas) approach, excavates a hole by lofting the lunar soil out of the hole, and (2) deploys the heat flow probe, which utilizes a coiled up tape as a thermal probe to reach greater than 3-meter depth. The system is a game-changer for small lunar landers as it exhibits extremely low mass, volume, and simple deployment. The pneumatic system takes advantage of the helium gas used for pressurizing liquid propellant of the lander. Normally, helium is vented once the lander is on the surface, but it can be utilized for powering pneumatic systems. Should sufficient helium not be available, a simple gas delivery system may be taken specifically for the heat flow probe. Either way, the pneumatic heat flow probe system would be much lighter than other systems that entirely rely on the electrical power of the lander.
NASA Technical Reports Server (NTRS)
Curry, Robert E.; Gilyard, Glenn B.
1989-01-01
A flight experiment was conducted to evaluate a pressure measurement system which uses pneumatic tubing and remotely located electronically scanned pressure transducer modules for in-flight unsteady aerodynamic studies. A parametric study of tubing length and diameter on the attenuation and lag of the measured signals was conducted. The hardware was found to operate satisfactorily at rates of up to 500 samples/sec per port in flight. The signal attenuation and lag due to tubing were shown to increase with tubing length, decrease with tubing diameter, and increase with altitude over the ranges tested. Measurable signal levels were obtained for even the longest tubing length tested, 4 ft, at frequencies up to 100 Hz. This instrumentation system approach provides a practical means of conducting detailed unsteady pressure surveys in flight.
Harmful Gas Recognition Exploiting a CTL Sensor Array
Wang, Qihui; Xie, Lijun; Zhu, Bo; Zheng, Yao; Cao, Shihua
2013-01-01
In this paper, a novel cataluminescence (CTL)-based sensor array consisting of nine types of catalytic materials is developed for the recognition of several harmful gases, namely carbon monoxide, acetone, chloroform and toluene. First, the experimental setup is constructed by using sensing nanomaterials, a heating plate, a pneumatic pump, a gas flow meter, a digital temperature device, a camera and a BPCL Ultra Weak Chemiluminescence Analyzer. Then, unique CTL patterns for the four types of harmful gas are obtained from the sensor array. The harmful gases are successful recognized by the PCA method. The optimal conditions are also investigated. Finally, experimental results show high sensitivity, long-term stability and good linearity of the sensor array, which combined with simplicity, make our system a promising application in this field. PMID:24113681
NASA Astrophysics Data System (ADS)
Zhang, Cun-quan; Zhong, Cheng
2015-03-01
The concept of a new type of pneumatically-driven split-Stirling-cycle cryocooler with clearance-phase-adjustor is proposed. In this implementation, the gap between the phase-adjusting part and the cylinder of the spring chamber is used, instead of dry friction acting on the pneumatically-driven rod to control motion damping of the displacer and to adjust the phase difference between the compression piston and displacer. It has the advantages of easy damping adjustment, low cost, and simplified manufacturing and assembly. A theoretical model has been established to simulate its dynamic performance. The linear compressor is modeled under adiabatic conditions, and the displacement of the compression piston is experimentally rectified. The working characteristics of the compressor motor and the principal losses of cooling, including regenerator inefficiency loss, solid conduction loss, shuttle loss, pump loss and radiation loss, are taken into account. The displacer motion was modeled as a single-degree-of-freedom (SDOF) forced system. A set of governing equations can be solved numerically to simulate the cooler's performance. The simulation is useful for understanding the physical processes occurring in the cooler and for predicting the cooler's performance.
Meyerspeer, M.; Krššák, M.; Kemp, G.J.; Roden, M.; Moser, E.
2016-01-01
1 Objective To develop a measurement method for interleaved acquisition of 1H and 31P STEAM localised spectra of exercising human calf muscle. 2 Materials and Methods A nonmagnetic exercise rig with a pneumatic piston and sensors for force and pedal angle was constructed to enable plantar flexion measured in the 3 Tesla MR scanner, which holds the dual tuned (1H,31P) surface coil used for signal transmission and reception. 3 Results 31P spectra acquired in interleaved mode benefit from higher SNR (factor of 1.34± 0.06 for PCr) compared to standard acquisition due to the Nuclear Overhauser effect (NOE) and substantial PCr/Pi changes during exercise can be observed in 31P spectra. 1H spectral quality is equal to that in single mode experiments and allows Cr2 changes to be monitored. 4 Conclusion The feasibility of dynamic interleaved localised 1H and 31P spectroscopy during plantar flexion exercise has been demonstrated using a custom-built pneumatic system for muscle activation. This opens the possibility of studying the dynamics of metabolism with multi nuclear MRS in a single run. PMID:16320091
CRLH-TL Sensors for Flow Inhomogeneties Detection of Pneumatic Conveyed Pulverized Solids
NASA Astrophysics Data System (ADS)
Angelovski, Aleksandar; Penirschke, Andreas; Jakoby, Rolf
2011-08-01
This paper presents an application of a Composite Right/Left-Handed (CRLH) Transmission Line resonator for a compact mass flow detector which is able to detect inhomogeneous flows. In this concept, series capacitors and shunt inductors are used to synthesize a medium with simultaneously negative permeability and permittivity - the so called metamaterial. The helix shape of the cylindrical CRLH-TL sensor offers the possibility to detect flow inhomogeneities within the pipeline which can be used to correct the detected massflow rate. A combination of two CRLH-TL structures within the same cross-section of the pipeline can improve the angular sensitivity of the sensor. A prototype was realized and tested in a dedicated measurement setup to prove the concept.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-04-16
...''); see also Issues and Decision Memorandum at Comment 6. Carbon Black: We have used the Thai import data for ``Rubber Grade Carbon Black'' to value all carbon black inputs.\\7\\ \\7\\ See Surrogate Value... Certain Material Inputs A. Carbon Black B. Bead Wire C. Nylon Tire Cord D. Natural Rubber E. Gap-filling...
Hydrogen Safety Sensor Performance and Use Gap Analysis: Preprint
DOE Office of Scientific and Technical Information (OSTI.GOV)
Buttner, William J; Burgess, Robert M; Schmidt, Kara
Hydrogen sensors are recognized as an important technology for facilitating the safe implementation of hydrogen as an alternative fuel, and there are numerous reports of a sensor alarm successfully preventing a potentially serious event. However, gaps in sensor metrological specifications, as well as in their performance for some applications, exist.The U.S. Department of Energy (DOE) Fuel Cell Technology Office published a short list of critical gaps in the 2007 and 2012 multiyear project plans; more detailed gap analyses were independently performed by the JRC and NREL. There have been, however, some significant advances in sensor technologies since these assessments, includingmore » the commercial availability of hydrogen sensors with fast response times (t90 less than 1 s, which had been an elusive DOE target since 2007), improved robustness to chemical poisons, improved selectivity, and improved lifetime and stability. These improvements, however, have not been universal and typically pertain to select platforms or models. Moreover, as hydrogen markets grow and new applications are being explored, more demands will be imposed on sensor performance. The hydrogen sensor laboratories at NREL and JRC are currently updating the hydrogen safety sensor gap analysis through direct interaction with international stakeholders in the hydrogen community, especially end-users. NREL and the JRC are currently organizing a series of workshops (in Europe and the U.S.) with sensor developers, end-users, and other stakeholders in 2017 to identify technology gaps and to develop a path forward to address them. One workshop is scheduled for May 10 in Brussels, Belgium at the Headquarters of the Fuel Cell and Hydrogen Joint Undertaking. A second workshop is planned at the National Renewable Energy Laboratory in Golden, CO, USA. This presentation will review improvements in sensor technologies in the past 5 to 10 years, identify gaps in sensor performance and use requirements, and identify potential research strategies to address the gaps. The presentation will also summarize the outcomes of the Hydrogen Sensors Workshops.« less
Externally Pressurized Journal Gas Bearings
NASA Technical Reports Server (NTRS)
Laub, John H.
1959-01-01
Externally pressurized gas-lubricated bearings with multiple orifice feed are investigated. An analytical treatment is developed for a semi-cylindrical bearing with 9 orifices and for a cylindrical journal bearing with 192 radial and 24 axial orifices. Experiments are described on models of the two bearing configurations with specially designed fixtures which incorporate pneumatic loading and means for determining pressure profiles, gas flow and gap height. The correlation between theory and experiment is satisfactory.
Preliminary measurements on heat balance in pneumatic tires
NASA Technical Reports Server (NTRS)
Nybakken, G. H.; Collart, D. Y.; Staples, R. J.; Lackey, J. I.; Clark, S. K.; Dodge, R. N.
1973-01-01
A variety of tests was undertaken to determine the nature of heat generation associated with a pneumatic tire operating under various conditions. Tests were conducted to determine the magnitude and distribution of internally generated heat caused by hysteresis in the rubber and ply fabric in an automobile tire operating under conditions of load, pressure, and velocity representative of normal operating conditions. These included tests at various yaw angles and tests with braking applied. In other tests, temperature sensors were mounted on a road to measure the effect of a tire rolling over and an attempt was made to deduce the magnitude and nature of interfacial friction from the resulting information. In addition, tests were performed using the scratch plate technique to determine the nature of the motion between the tire and road. Finally, a model tire was tested on a roadwheel, the surface covering which could be changed, and an optical pyrometer was used to measure rubber surface temperatures.
Venkatesan, Lalit; Barlow, Steven M.
2014-01-01
TAC-Cell is a custom-built somatosensory stimulator that delivers pneumatic cutaneous tactile inputs to virtually any skin target on the body and by virtue of its non-ferrous materials is compatible with functional magnetic resonance imaging (fMRI) and magnetoencephalography (MEG) brain scanners. In this study, we describe the method to measure apparent skin displacement induced by TAC-Cell stimulation of the glabrous surface of the distal phalanx of the index finger. Specifically, we studied the effect of four servo controller input voltages (0.4V to 1.0V) on resultant skin displacement among eighteen, neurotypical adult male and female participants. A fiberoptic displacement sensor, commonly used in industrial applications, was coupled to the TAC-Cell to measure the glabrous skin’s kinematic response to different stimulus amplitudes. Skin displacement was significantly dependent on stimulus amplitudes and sex (p< 0.0001). Power spectrum and kinematic analysis of skin displacement showed that the pneumatic TAC-Cell stimulus consists of a spectrally rich, high velocity signal. In related work, we have shown that this dynamic pneumocutaneous stimulus is highly effective in evoking a cortical brain response for neurodiagnostic applications and somatosensory pathway analysis in health and disease. PMID:24856834
Venkatesan, Lalit; Barlow, Steven M
2014-07-18
TAC-Cell is a custom-built somatosensory stimulator that delivers pneumatic cutaneous tactile inputs to virtually any skin target on the body and by virtue of its non-ferrous materials is compatible with functional magnetic resonance imaging (fMRI) and magnetoencephalography (MEG) brain scanners. In this study, we describe the method to measure apparent skin displacement induced by TAC-Cell stimulation of the glabrous surface of the distal phalanx of the index finger. Specifically, we studied the effect of four servo controller input voltages (0.4V-1.0 V) on resultant skin displacement among eighteen, neurotypical adult male and female participants. A fiberoptic displacement sensor, commonly used in industrial applications, was coupled to the TAC-Cell to measure the glabrous skin׳s kinematic response to different stimulus amplitudes. Skin displacement was significantly dependent on stimulus amplitudes and sex (p<0.0001). Power spectrum and kinematic analysis of skin displacement showed that the pneumatic TAC-Cell stimulus consists of a spectrally rich, high velocity signal. In related work, we have shown that this dynamic pneumocutaneous stimulus is highly effective in evoking a cortical brain response for neurodiagnostic applications and somatosensory pathway analysis in health and disease. Copyright © 2014 Elsevier Ltd. All rights reserved.
A Comprehensive Study on Technologies of Tyre Monitoring Systems and Possible Energy Solutions
Kubba, Ali E.; Jiang, Kyle
2014-01-01
This article presents an overview on the state of the art of Tyre Pressure Monitoring System related technologies. This includes examining the latest pressure sensing methods and comparing different types of pressure transducers, particularly their power consumption and measuring range. Having the aim of this research to investigate possible means to obtain a tyre condition monitoring system (TCMS) powered by energy harvesting, various approaches of energy harvesting techniques were evaluated to determine which approach is the most applicable for generating energy within the pneumatic tyre domain and under rolling tyre dynamic conditions. This article starts with an historical review of pneumatic tyre development and demonstrates the reasons and explains the need for using a tyre condition monitoring system. Following this, different tyre pressure measurement approaches are compared in order to determine what type of pressure sensor is best to consider in the research proposal plan. Then possible energy harvesting means inside land vehicle pneumatic tyres are reviewed. Following this, state of the art battery-less tyre pressure monitoring systems developed by individual researchers or by world leading tyre manufacturers are presented. Finally conclusions are drawn based on the reviewed documents cited in this article and a research proposal plan is presented. PMID:24922457
A Laser-Based Measuring System for Online Quality Control of Car Engine Block.
Li, Xing-Qiang; Wang, Zhong; Fu, Lu-Hua
2016-11-08
For online quality control of car engine production, pneumatic measurement instrument plays an unshakeable role in measuring diameters inside engine block because of its portability and high-accuracy. To the limitation of its measuring principle, however, the working space between the pneumatic device and measured surface is too small to require manual operation. This lowers the measuring efficiency and becomes an obstacle to perform automatic measurement. In this article, a high-speed, automatic measuring system is proposed to take the place of pneumatic devices by using a laser-based measuring unit. The measuring unit is considered as a set of several measuring modules, where each of them acts like a single bore gauge and is made of four laser triangulation sensors (LTSs), which are installed on different positions and in opposite directions. The spatial relationship among these LTSs was calibrated before measurements. Sampling points from measured shaft holes can be collected by the measuring unit. A unified mathematical model was established for both calibration and measurement. Based on the established model, the relative pose between the measuring unit and measured workpiece does not impact the measuring accuracy. This frees the measuring unit from accurate positioning or adjustment, and makes it possible to realize fast and automatic measurement. The proposed system and method were finally validated by experiments.
An automated quasi-continuous capillary refill timing device
Blaxter, L L; Morris, D E; Crowe, J A; Henry, C; Hill, S; Sharkey, D; Vyas, H; Hayes-Gill, B R
2016-01-01
Capillary refill time (CRT) is a simple means of cardiovascular assessment which is widely used in clinical care. Currently, CRT is measured through manual assessment of the time taken for skin tone to return to normal colour following blanching of the skin surface. There is evidence to suggest that manually assessed CRT is subject to bias from ambient light conditions, a lack of standardisation of both blanching time and manually applied pressure, subjectiveness of return to normal colour, and variability in the manual assessment of time. We present a novel automated system for CRT measurement, incorporating three components: a non-invasive adhesive sensor incorporating a pneumatic actuator, a diffuse multi-wavelength reflectance measurement device, and a temperature sensor; a battery operated datalogger unit containing a self contained pneumatic supply; and PC based data analysis software for the extraction of refill time, patient skin surface temperature, and sensor signal quality. Through standardisation of the test, it is hoped that some of the shortcomings of manual CRT can be overcome. In addition, an automated system will facilitate easier integration of CRT into electronic record keeping and clinical monitoring or scoring systems, as well as reducing demands on clinicians. Summary analysis of volunteer (n = 30) automated CRT datasets are presented, from 15 healthy adults and 15 healthy children (aged from 5 to 15 years), as their arms were cooled from ambient temperature to 5°C. A more detailed analysis of two typical datasets is also presented, demonstrating that the response of automated CRT to cooling matches that of previously published studies. PMID:26642080
Removal of unburned carbon from coal fly ash using a pneumatic triboelectrostatic separator.
Kim, J K; Cho, H C; Kim, S C
2001-01-01
A pneumatic triboelectrostatic beneficiation system of fly ash was studied using a continuous, bench-scale electroseparator composed of two vertical electrode plates and an ejector-tribocharger. Tests were conducted to evaluate the charge density and the separation efficiency at various operating conditions. It was found that the higher charge densities were obtained at (1) the air flow rate of 1.75 m3/min. (2) the feed rate of less than 50 kg/h. and (3) the relative humidity of less than 30% with use of a stainless ejector tribocharger. With these optimum conditions, the clean ash of less than LOI 3% was recovered with a yield over 75% when operated at the diffuser slit gap of 4mm, the diffuser outlet velocity of 16.1-18.6 m/s, and the distance of 15 cm between diffuser slit and splitter. The optimum feed rate was found to be 740 kg/h per m2 of electrode surface area, which can be used as a scale-up factor of electroseparator.
A Laser-Based Measuring System for Online Quality Control of Car Engine Block
Li, Xing-Qiang; Wang, Zhong; Fu, Lu-Hua
2016-01-01
For online quality control of car engine production, pneumatic measurement instrument plays an unshakeable role in measuring diameters inside engine block because of its portability and high-accuracy. To the limitation of its measuring principle, however, the working space between the pneumatic device and measured surface is too small to require manual operation. This lowers the measuring efficiency and becomes an obstacle to perform automatic measurement. In this article, a high-speed, automatic measuring system is proposed to take the place of pneumatic devices by using a laser-based measuring unit. The measuring unit is considered as a set of several measuring modules, where each of them acts like a single bore gauge and is made of four laser triangulation sensors (LTSs), which are installed on different positions and in opposite directions. The spatial relationship among these LTSs was calibrated before measurements. Sampling points from measured shaft holes can be collected by the measuring unit. A unified mathematical model was established for both calibration and measurement. Based on the established model, the relative pose between the measuring unit and measured workpiece does not impact the measuring accuracy. This frees the measuring unit from accurate positioning or adjustment, and makes it possible to realize fast and automatic measurement. The proposed system and method were finally validated by experiments. PMID:27834839
Shimada, Youichi; Terayama, Yukio
2006-01-01
This report represents the development of the prototype transtibial prosthesis to assist a smooth and comfortable walking for an unilateral amputee. This prosthesis is composed of two air cylinders, solenoid valves, portable and small air tank for compressed air storage, a multiple sensor system and a microprocessor. Two air cylinders are located around the rods to act as antagonistic and agonistic muscles. The system causes flexion and extension of the foot plate jointed at the ankle with compressed air, injected -or discharged via a solenoid or electromagnetic valves. The valves or solenoids are controlled with a microprocessor (Microchip Technology Inc., PIC16F876), the microprocessor generates control signals to the interface circuits for valve opening and closing consistent with the foot position during the walking phase. The control patterns generated in the microprocessor are modified with feedback from the touch sensor, ankle joint angle sensor and the two dimensional acceleration sensor. The primary walking pattern for an individual amputee should be developed through the gait analysis with video.
IceBreaker: Mars Drill and Sample Delivery System
NASA Astrophysics Data System (ADS)
Mellerowicz, B. L.; Paulsen, G. L.; Zacny, K.; McKay, C.; Glass, B. J.; Dave, A.; Davila, A. F.; Marinova, M.
2012-12-01
We report on the development and testing of a one meter class prototype Mars drill and cuttings sample delivery system. The IceBreaker drill consists of a rotary-percussive drill head, a sampling auger with a bit at the end having an integrated temperature sensor, a Z-stage for advancing the auger into the ground, and a sam-pling station for moving the augered ice shavings or soil cuttings into a sample cup. The drill is deployed from a 3 Degree of Freedom (DOF) robotic arm. The drill demonstrated drilling in ice-cemented ground, ice, and rocks at the 1-1-100-100 level; that is the drill reached 1 meter in 1 hour with 100 Watts of power and 100 Newton Weight on Bit. This cor-responds to an average energy of 100 Whr. The drill has been extensively tested in the Mars chamber to a depth of 1 meter, as well as in the Antarctic and the Arctic Mars analog sites. We also tested three sample delivery systems: 1) 4 DOF arm with a custom soil scoop at the end; 2) Pneumatic based, and 3) Drill based enabled by the 3 (DOF) drill deployment boom. In all approaches there is an air-gap between the sterilized drill (which penetrates subsurface) and the sample transfer hardware (which is not going to be sterilized). The air gap satisfies the planetary protection requirements. The scoop acquires cuttings sample once they are augered to the surface, and drops them into an in-strument inlet port. The system has been tested in the Mars chamber and in the Arctic. The pneumatic sample delivery system uses compressed gas to move the sample captured inside a small chamber inte-grated with the auger, directly into the instrument. The system was tested in the Mars chamber. In the third approach the drill auger captures the sample on its flutes, the 3 DOF boom positions the tip of the auger above the instrument, and then the auger discharges the sample into an instrument. This approach was tested in the labolatory (at STP). The above drilling and sample delivery tests have shown that drilling and sample transfer on Mars, in ice cemented ground with limited power, energy and Weight on Bit, and collecting samples in dis-crete depth intervals is possible within the given mass, power, and energy levels of a Phoenix-size lander and within the duration of a Phoenix-like mission.
Fast acting multiple element valve
Yang, Jefferson Y. S.; Wada, James M.
1991-01-01
A plurality of slide valve elements having plural axial-spaced annular parts and an internal slide are inserted into a bulkhead in a fluid conduit from a downstream side of the bulkhead, locked in place by a bayonet coupling and set screw, and project through the bulkhead into the upstream conduit. Pneumatic lines connecting the slide valve element actuator to pilot valves are brought out the throat of the valve element to the downstream side. Pilot valves are radially spaced around the exterior of the valve to permit the pneumatic lines to be made identical, thereby to minimize adverse timing tolerances in operation due to pressure variations. Ring manifolds surround the valve adjacent respective pilot valve arrangements to further reduce adverse timing tolerances due to pressure variations, the manifolds being directly connected to the respective pilot valves. Position sensors are provided the valve element slides to signal the precise time at which a slide reaches or passes through a particular point in its stroke to initiate a calibrated timing function.
NASA Astrophysics Data System (ADS)
Farag, Mohannad; Zainul Azlan, Norsinnira; Hayyan Alsibai, Mohammed
2018-04-01
This paper presents the design and fabrication of a three-fingered anthropomorphic robotic hand. The fingers are driven by tendons and actuated by human muscle-like actuators known as Pneumatic Artificial Muscle (PAM). The proposed design allows the actuators to be mounted outside the hand where each finger can be driven by one PAM actuator and six indirectly interlinked tendons. With this design, the three-fingered hand has a compact size and a lightweight with a mass of 150.25 grams imitating the human being hand in terms of size and weight. The hand also successfully grasped objects with different shapes and weights up to 500 g. Even though the number of PAM actuators equals the number of Degrees of Freedom (DOF), the design guarantees driving of three joints by only one actuator reducing the number of required actuators from 3 to 1. Therefore, this hand is suitable for researches of robotic applications in terms of design, cost and ability to be equipped with several types of sensors.
Connecting apparatus for limited rotary or rectilinear motion
Hardin, Jr., Roy T.
1981-11-10
Apparatus for providing connection between two members movable in a horizontal plane with respect to each other in a rotary or linear fashion. The apparatus includes a set of horizontal shelves affixed to each of the two members, vertically aligned across a selected gap. A number of cables or hoses, for electrical, hydraulic or pneumatic connection are arranged on the aligned shelves in a U-shaped loop, connected through their extremities to the two members, so that through a sliding motion portions of the cable are transferred from one shelf to the other, across the gap, upon relative motion of the members. The apparatus is particularly adaptable to the rotating plugs of the reactor vessel head of a nuclear reactor.
Particulate matter sensor with a heater
Hall, Matthew [Austin, TX
2011-08-16
An apparatus to detect particulate matter. The apparatus includes a sensor electrode, a shroud, and a heater. The electrode measures a chemical composition within an exhaust stream. The shroud surrounds at least a portion of the sensor electrode, exclusive of a distal end of the sensor electrode exposed to the exhaust stream. The shroud defines an air gap between the sensor electrode and the shroud and an opening toward the distal end of the sensor electrode. The heater is mounted relative to the sensor electrode. The heater burns off particulate matter in the air gap between the sensor electrode and the shroud.
Development of 3 DOF manipulator using ER fluid clutches for reduction of collision force
NASA Astrophysics Data System (ADS)
Boku, Kazuhiko; Nakamura, Taro
2009-02-01
.With robots and users more commonly sharing space such as in the fields of medicine and home automation, the possibility of a physical collision has increased, even though many robots use actuators with high-ratio gear trains to minimize the effects of impact. We developed a 3-DOF manipulator having a smart flexible joint using an ER fluid and a sensor-equipped pneumatic cushion. Results of position control and collision experiments using the manipulator demonstrated its effectiveness.
The MK VI - A second generation attitude control system
NASA Astrophysics Data System (ADS)
Meredith, P. J.
1986-10-01
The MK VI, a new multipurpose attitude control system for the exoatmospheric attitude control of sounding rocket payloads, is described. The system employs reprogrammable microcomputer memory for storage of basic control logic and for specific mission event control data. The paper includes descriptions of MK VI specifications and configuration; sensor characteristics; the electronic, analog, and digital sections; the pneumatic system; ground equipment; the system operation; and software. A review of the MK VI performance for the Comet Halley flight is presented. Block diagrams are included.
Photographic Equipment Test System (PETS)
NASA Technical Reports Server (NTRS)
1975-01-01
The Photographic Equipment Test System is presented. The device is a mobile optical system designed for evaluating performance of various sensors in a laboratory, in a vacuum chamber or on a flight line. The carriage is designed to allow elevation as well as azimuth control of the direction of the light from the collimator. The pneumatic tires provide an effective vibration isolation system. A target/illumination system is mounted on a motor driven linear slide, and focusing and exposure control can be operated remotely from the small electronics control console.
Small Business Innovations (Cryostat)
NASA Technical Reports Server (NTRS)
1991-01-01
General Pneumatics Corporation, Scottsdale, AZ, developed an anti- clogging cryostat that liquifies gases by expansion for high pressure through a nozzle to produce cryorefrigeration based on their Kennedy Space Center Small Business Innovation Research (SBIR) work to develop a Joule-Thomson (JT) expansion valve that is less susceptible to clogging by particles or condensed contaminants in the flow than a non-contaminating compressor in a closed cycle Linde-Hampson cryocooler used to generate cryogenic cooling for infrared sensors, super conductors, supercooled electronics and cryosurgery.
Watanabe, Akinobu; Eugenia Leone Gold, Maria; Brusatte, Stephen L.; Benson, Roger B. J.; Choiniere, Jonah; Davidson, Amy; Norell, Mark A.
2015-01-01
Among extant vertebrates, pneumatization of postcranial bones is unique to birds, with few known exceptions in other groups. Through reduction in bone mass, this feature is thought to benefit flight capacity in modern birds, but its prevalence in non-avian dinosaurs of variable sizes has generated competing hypotheses on the initial adaptive significance of postcranial pneumaticity. To better understand the evolutionary history of postcranial pneumaticity, studies have surveyed its distribution among non-avian dinosaurs. Nevertheless, the degree of pneumaticity in the basal coelurosaurian group Ornithomimosauria remains poorly known, despite their potential to greatly enhance our understanding of the early evolution of pneumatic bones along the lineage leading to birds. Historically, the identification of postcranial pneumaticity in non-avian dinosaurs has been based on examination of external morphology, and few studies thus far have focused on the internal architecture of pneumatic structures inside the bones. Here, we describe the vertebral pneumaticity of the ornithomimosaur Archaeornithomimus with the aid of X-ray computed tomography (CT) imaging. Complementary examination of external and internal osteology reveals (1) highly pneumatized cervical vertebrae with an elaborate configuration of interconnected chambers within the neural arch and the centrum; (2) anterior dorsal vertebrae with pneumatic chambers inside the neural arch; (3) apneumatic sacral vertebrae; and (4) a subset of proximal caudal vertebrae with limited pneumatic invasion into the neural arch. Comparisons with other theropod dinosaurs suggest that ornithomimosaurs primitively exhibited a plesiomorphic theropod condition for axial pneumaticity that was extended among later taxa, such as Archaeornithomimus and large bodied Deinocheirus. This finding corroborates the notion that evolutionary increases in vertebral pneumaticity occurred in parallel among independent lineages of bird-line archosaurs. Beyond providing a comprehensive view of vertebral pneumaticity in a non-avian coelurosaur, this study demonstrates the utility and need of CT imaging for further clarifying the early evolutionary history of postcranial pneumaticity. PMID:26682888
Sliding pressure control valve for pneumatic hammer drill
Polsky, Yarom [Albuquerque, NM
2011-08-30
A pneumatic device control apparatus and method comprising a ported valve slidably fitted over a feed tube of the pneumatic device, and using a compliant biasing device to constrain motion of the valve to provide asymmetric timing for extended pressurization of a power chamber and reduced pressurization of a return chamber of the pneumatic device. The pneumatic device can be a pneumatic hammer drill.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Saheed, M. Shuaib M.; Muti Mohamed, Norani; Arif Burhanudin, Zainal, E-mail: zainabh@petronas.com.my
2014-03-24
Ionization gas sensors using vertically aligned multi-wall carbon nanotubes (MWCNT) are demonstrated. The sharp tips of the nanotubes generate large non-uniform electric fields at relatively low applied voltage. The enhancement of the electric field results in field emission of electrons that dominates the breakdown mechanism in gas sensor with gap spacing below 14 μm. More than 90% reduction in breakdown voltage is observed for sensors with MWCNT and 7 μm gap spacing. Transition of breakdown mechanism, dominated by avalanche electrons to field emission electrons, as decreasing gap spacing is also observed and discussed.
A new pneumatic suspension system with independent stiffness and ride height tuning capabilities
NASA Astrophysics Data System (ADS)
Yin, Zhihong; Khajepour, Amir; Cao, Dongpu; Ebrahimi, Babak; Guo, Konghui
2012-12-01
This paper introduces a new pneumatic spring for vehicle suspension systems, allowing independent tuning of stiffness and ride height according to different vehicle operating conditions and driver preferences. The proposed pneumatic spring comprises a double-acting pneumatic cylinder, two accumulators and a tuning subsystem. This paper presents a detailed description of the pneumatic spring and its working principle. The mathematical model is established based on principles of thermo and fluid dynamics. An experimental setup has been designed and fabricated for testing and evaluating the proposed pneumatic spring. The analytical and experimental results confirm the capability of the new pneumatic spring system for independent tuning of stiffness and ride height. The mathematical model is verified and the capabilities of the pneumatic spring are further proved. It is concluded that this new pneumatic spring provides a more flexible suspension design alternative for meeting various conflicting suspension requirements for ride comfort and performance.
Assistive acting movement therapy devices with pneumatic rotary-type soft actuators.
Wilkening, André; Baiden, David; Ivlev, Oleg
2012-12-01
Inherent compliance and assistive behavior are assumed to be essential properties for safe human-robot interaction. Rehabilitation robots demand the highest standards in this respect because the machine interacts directly with weak persons who are often sensitive to pain. Using novel soft fluidic actuators with rotary elastic chambers (REC actuators), compact, lightweight, and cost-effective therapeutic devices can be developed. This article describes modular design and control strategies for new assistive acting robotic devices for upper and lower extremities. Due to the inherent compliance and natural back-drivability of pneumatic REC actuators, these movement therapy devices provide gentle treatment, whereby the interaction forces between humans and the therapy device are estimated without the use of expensive force/torque sensors. An active model-based gravity compensation based on separated models of the robot and of the individual patient's extremity provides the basis for effective assistive control. The utilization of pneumatic actuators demands a special safety concept, which is merged with control algorithms to provide a sufficient level of safeness and to catch any possible system errors and/or emergency situations. A self-explanatory user interface allows for easy, intuitive handling. Prototypes are very comfortable for use due to several control routines that work in the background. Assistive devices have been tested extensively with several healthy persons; the knee/hip movement therapy device is now under clinical trials at the Clinic for Orthopaedics and Trauma Surgery at the Klinikum Stuttgart.
Pneumatic Distension of Ventricular Mural Architecture Validated Histologically.
Burg, M C; Lunkenheimer, P; Niederer, P; Brune, C; Redmann, K; Smerup, M; Spiegel, U; Becker, F; Maintz, D; Heindel, W; Anderson, R H
2016-11-01
Purpose: There are ongoing arguments as to how cardiomyocytes are aggregated together within the ventricular walls. We used pneumatic distension through the coronary arteries to exaggerate the gaps between the aggregated cardiomyocytes, analyzing the pattern revealed using computed tomography, and validating our findings by histology. Methods: We distended 10 porcine hearts, arresting 4 in diastole by infusion of cardioplegic solutions, and 4 in systole by injection of barium chloride. Mural architecture was revealed by computed tomography, measuring also the angulations of the long chains of cardiomyocytes. We prepared the remaining 2 hearts for histology by perfusion with formaldehyde. Results: Increasing pressures of pneumatic distension elongated the ventricular walls, but produced insignificant changes in mural thickness. The distension exaggerated the spaces between the aggregated cardiomyocytes, compartmenting the walls into epicardial, central, and endocardial regions, with a feathered arrangement of transitions between them. Marked variation was noted in the thicknesses of the parts in the different ventricular segments, with no visible anatomical boundaries between them. Measurements of angulations revealed intruding and extruding populations of cardiomyocytes that deviated from a surface-parallel alignment. Scrolling through the stacks of tomographic images revealed marked spiraling of the aggregated cardiomyocytes when traced from base to apex. Conclusion: Our findings call into question the current assumption that cardiomyocytes are uniformly aggregated together in a tangential fashion. There is marked heterogeneity in the architecture of the different ventricular segments, with the aggregated units never extending in a fully transmural fashion. Key Points: • Pneumographic computed tomography reveals an organized structure of the ventricular walls.• Aggregated cardiomyocytes form a structured continuum, with marked regional heterogeneity.• Global ventricular function results from antagonistic forces generated by aggregated cardiomyocytes. Citation Format: • Burg MC, Lunkenheimer P, Niederer P et al. Pneumatic Distension of Ventricular Mural Architecture Validated Histologically. Fortschr Röntgenstr 2016; 188: 1045 - 1053. © Georg Thieme Verlag KG Stuttgart · New York.
Switching algorithm for maglev train double-modular redundant positioning sensors.
He, Ning; Long, Zhiqiang; Xue, Song
2012-01-01
High-resolution positioning for maglev trains is implemented by detecting the tooth-slot structure of the long stator installed along the rail, but there are large joint gaps between long stator sections. When a positioning sensor is below a large joint gap, its positioning signal is invalidated, thus double-modular redundant positioning sensors are introduced into the system. This paper studies switching algorithms for these redundant positioning sensors. At first, adaptive prediction is applied to the sensor signals. The prediction errors are used to trigger sensor switching. In order to enhance the reliability of the switching algorithm, wavelet analysis is introduced to suppress measuring disturbances without weakening the signal characteristics reflecting the stator joint gap based on the correlation between the wavelet coefficients of adjacent scales. The time delay characteristics of the method are analyzed to guide the algorithm simplification. Finally, the effectiveness of the simplified switching algorithm is verified through experiments.
Switching Algorithm for Maglev Train Double-Modular Redundant Positioning Sensors
He, Ning; Long, Zhiqiang; Xue, Song
2012-01-01
High-resolution positioning for maglev trains is implemented by detecting the tooth-slot structure of the long stator installed along the rail, but there are large joint gaps between long stator sections. When a positioning sensor is below a large joint gap, its positioning signal is invalidated, thus double-modular redundant positioning sensors are introduced into the system. This paper studies switching algorithms for these redundant positioning sensors. At first, adaptive prediction is applied to the sensor signals. The prediction errors are used to trigger sensor switching. In order to enhance the reliability of the switching algorithm, wavelet analysis is introduced to suppress measuring disturbances without weakening the signal characteristics reflecting the stator joint gap based on the correlation between the wavelet coefficients of adjacent scales. The time delay characteristics of the method are analyzed to guide the algorithm simplification. Finally, the effectiveness of the simplified switching algorithm is verified through experiments. PMID:23112657
Novel Fabry-Perot fiber optic sensor with multiple applications
NASA Astrophysics Data System (ADS)
Chen, Xiaopei; Shen, Fabin; Wang, Anbo; Wang, Zhuang; Zhang, Yan
2004-12-01
A novel Intrinsic Fabry-Perot fiber-optic sensor is presented in this paper. The sensors were made through two simple steps: wet chemical etch and fusion splice. Micro air-gaps were generated inside the fibers and functioned as reflective mirrors. This procedure not only provides a simple and cost effective technology for fabricating intrinsic Fabry-Perot Interferometric (IFPI) fiber sensors, but also provides two possible IFPI structures. Both of the fiber cavity between the air-gaps or the air-gap and cleaved fiber end can be used as sensing elements. With these two structures, this sensor can be used to measure the temperature, strain, pressure, refractive index of chemicals and the thin film thickness by itself. Multi-point measurements can also be achieved by multiplexing. Furthermore, it also can be multiplexed with other sensors such as Long Period Gratings (LPG) to provide compensations for other perturbation sensing. Theoretical and experimental studies of two sensor structures are described. Experimental results show that high resolution and high sensitivity can be obtained with appropriate signal processing.
Extrinsic fiber optic displacement sensors and displacement sensing systems
Murphy, K.A.; Gunther, M.F.; Vengsarkar, A.M.; Claus, R.O.
1994-04-05
An extrinsic Fizeau fiber optic sensor comprises a single-mode fiber, used as an input/output fiber, and a multimode fiber, used purely as a reflector, to form an air gap within a silica tube that acts as a Fizeau cavity. The Fresnel reflection from the glass/air interface at the front of the air gap (reference reflection) and the reflection from the air/glass interface at the far end of the air gap (sensing reflection) interfere in the input/output fiber. The two fibers are allowed to move in the silica tube, and changes in the air gap length cause changes in the phase difference between the reference reflection and the sensing reflection. This phase difference is observed as changes in intensity of the light monitored at the output arm of a fused biconical tapered coupler. The extrinsic Fizeau fiber optic sensor behaves identically whether it is surface mounted or embedded, which is unique to the extrinsic sensor in contrast to intrinsic Fabry-Perot sensors. The sensor may be modified to provide a quadrature phase shift extrinsic Fizeau fiber optic sensor for the detection of both the amplitude and the relative polarity of dynamically varying strain. The quadrature light signals may be generated by either mechanical or optical means. A plurality of the extrinsic sensors may connected in cascade and multiplexed to allow monitoring by a single analyzer. 14 figures.
Extrinsic fiber optic displacement sensors and displacement sensing systems
Murphy, Kent A.; Gunther, Michael F.; Vengsarkar, Ashish M.; Claus, Richard O.
1994-01-01
An extrinsic Fizeau fiber optic sensor comprises a single-mode fiber, used as an input/output fiber, and a multimode fiber, used purely as a reflector, to form an air gap within a silica tube that acts as a Fizeau cavity. The Fresnel reflection from the glass/air interface at the front of the air gap (reference reflection) and the reflection from the air/glass interface at the far end of the air gap (sensing reflection) interfere in the input/output fiber. The two fibers are allowed to move in the silica tube, and changes in the air gap length cause changes in the phase difference between the reference reflection and the sensing reflection. This phase difference is observed as changes in intensity of the light monitored at the output arm of a fused biconical tapered coupler. The extrinsic Fizeau fiber optic sensor behaves identically whether it is surface mounted or embedded, which is unique to the extrinsic sensor in contrast to intrinsic Fabry-Perot sensors. The sensor may be modified to provide a quadrature phase shift extrinsic Fizeau fiber optic sensor for the detection of both the amplitude and the relative polarity of dynamically varying strain. The quadrature light signals may be generated by either mechanical or optical means. A plurality of the extrinsic sensors may connected in cascade and multiplexed to allow monitoring by a single analyzer.
Pneumatic Valve Operated by Multiplex Pneumatic Transmission
NASA Astrophysics Data System (ADS)
Nishioka, Yasutaka; Suzumori, Koichi; Kanda, Takefumi; Wakimoto, Shuichi
A pneumatic system has several advantages, which are cheapness, lightweight, and reliability to human and environment. These advantages are adapted to some research areas, such as industrial lines, medical and nursing cares, and rehabilitation tools. However, the pneumatic system needs several devices; compressor, air tube, and control valve. This research aim to downsize pneumatic system. In this paper, a new method of multiplex pneumatic transmission for multi-pneumatic servo system is proposed. The valve for this system consists of two vibrators supported by springs, which was designed with simple and cheap structure. The working principle of the valve is vibrators resonance from multiplex pneumatic transmission and it is possible to work as ON/OFF valves without electric wire. Dynamic simulation was used to confirm the working principle of the resonance driving system. A prototype device confirming the principle was designed and developed based on the simulation. The experiments show that this new control system works very well to control two separated valves through single pneumatic tube.
Lin, Jia-Hua; McGorry, Raymond W; Chang, Chien-Chi
2007-05-01
A hand-handle interface force and torque measurement system is introduced to fill the void acknowledged in the international standard ISO 6544, which governs pneumatic, assembly tool reaction torque and force measurement. This system consists of an instrumented handle with a sensor capable of measuring grip force and reaction hand moment when threaded, fastener-driving tools are used by operators. The handle is rigidly affixed to the tool in parallel to the original tool handle allowing normal fastener-driving operations with minimal interference. Demonstration of this proposed system was made with tools of three different shapes: pistol grip, right angle, and in-line. During tool torque buildup, the proposed system measured operators exerting greater grip force on the soft joint than on the hard joint. The system also demonstrated that the soft joint demanded greater hand moment impulse than the hard joint. The results demonstrate that the measurement system can provide supplemental data useful in exposure assessment with power hand tools as proposed in ISO 6544.
Design of flat pneumatic artificial muscles
NASA Astrophysics Data System (ADS)
Wirekoh, Jackson; Park, Yong-Lae
2017-03-01
Pneumatic artificial muscles (PAMs) have gained wide use in the field of robotics due to their ability to generate linear forces and motions with a simple mechanism, while remaining lightweight and compact. However, PAMs are limited by their traditional cylindrical form factors, which must increase radially to improve contraction force generation. Additionally, this form factor results in overly complicated fabrication processes when embedded fibers and sensor elements are required to provide efficient actuation and control of the PAMs while minimizing the bulkiness of the overall robotic system. In order to overcome these limitations, a flat two-dimensional PAM capable of being fabricated using a simple layered manufacturing process was created. Furthermore, a theoretical model was developed using Von Karman’s formulation for large deformations and the energy methods. Experimental characterizations of two different types of PAMs, a single-cell unit and a multi-cell unit, were performed to measure the maximum contraction lengths and forces at input pressures ranging from 0 to 150 kPa. Experimental data were then used to verify the fidelity of the theoretical model.
Novel infrared detector based on a tunneling displacement transducer
NASA Technical Reports Server (NTRS)
Kenny, T. W.; Kaiser, W. J.; Waltman, S. B.; Reynolds, J. K.
1991-01-01
The paper describes the design, fabrication, and characteristics of a novel infrared detector based on the principle of Golay's (1947) pneumatic infrared detector, which uses the expansion of a gas to detect infrared radiation. The present detector is constructed entirely from micromachined silicon and uses an electron tunneling displacement transducer for the detection of gas expansion. The sensitivity of the new detector is competitive with the best commercial pyroelectric sensors and can be readily improved by an order of magnitude through the use of an optimized transducer.
Design and Dynamic Model of a Frog-inspired Swimming Robot Powered by Pneumatic Muscles
NASA Astrophysics Data System (ADS)
Fan, Ji-Zhuang; Zhang, Wei; Kong, Peng-Cheng; Cai, He-Gao; Liu, Gang-Feng
2017-09-01
Pneumatic muscles with similar characteristics to biological muscles have been widely used in robots, and thus are promising drivers for frog inspired robots. However, the application and nonlinearity of the pneumatic system limit the advance. On the basis of the swimming mechanism of the frog, a frog-inspired robot based on pneumatic muscles is developed. To realize the independent tasks by the robot, a pneumatic system with internal chambers, micro air pump, and valves is implemented. The micro pump is used to maintain the pressure difference between the source and exhaust chambers. The pneumatic muscles are controlled by high-speed switch valves which can reduce the robot cost, volume, and mass. A dynamic model of the pneumatic system is established for the simulation to estimate the system, including the chamber, muscle, and pneumatic circuit models. The robot design is verified by the robot swimming experiments and the dynamic model is verified through the experiments and simulations of the pneumatic system. The simulation results are compared to analyze the functions of the source pressure, internal volume of the muscle, and circuit flow rate which is proved the main factor that limits the response of muscle pressure. The proposed research provides the application of the pneumatic muscles in the frog inspired robot and the pneumatic model to study muscle controller.
NASA Astrophysics Data System (ADS)
Wang, Anbo; Miller, Mark S.; Gunther, Michael F.; Murphy, Kent A.; Claus, Richard O.
1993-03-01
A self-referencing technique compensating for fiber losses and source fluctuations in air-gap intensity-based optical fiber sensors is described and demonstrated. A resolution of 0.007 micron has been obtained over a measurement range of 0-250 microns for an intensity-based displacement sensor using this referencing technique. The sensor is shown to have minimal sensitivity to fiber bending losses and variations in the LED input power. A theoretical model for evaluation of step-index multimode optical fiber splice is proposed. The performance of the sensor as a displacement sensor agrees well with the theoretical analysis.
Maffiodo, Daniela; De Nisco, Giuseppe; Gallo, Diego; Audenino, Alberto; Morbiducci, Umberto; Ferraresi, Carlo
2016-04-01
This work investigates the effect that the application of intermittent pneumatic compression to lower limbs has on the cardiovascular system. Intermittent pneumatic compression can be applied to subjects with reduced or null mobility and can be useful for therapeutic purposes in sports recovery, deep vein thrombosis prevention and lymphedema drainage. However, intermittent pneumatic compression performance and the effectiveness are often difficult to predict. This study presents a reduced-order numerical model of the interaction between the cardiovascular system and the intermittent pneumatic compression device. The effect that different intermittent pneumatic compression operating conditions have on the overall circulation is investigated. Our findings confirm (1) that an overall positive effect on hemodynamics can be obtained by properly applying the intermittent pneumatic compression device and (2) that using intermittent pneumatic compression for cardiocirculatory recovery is feasible in subjects affected by lower limb disease. © IMechE 2016.
NASA Astrophysics Data System (ADS)
Coogan, A.; Avanzi, F.; Akella, R.; Conklin, M. H.; Bales, R. C.; Glaser, S. D.
2017-12-01
Automatic meteorological and snow stations provide large amounts of information at dense temporal resolution, but data quality is often compromised by noise and missing values. We present a new gap-filling and cleaning procedure for networks of these stations based on Kalman filtering and expectation maximization. Our method utilizes a multi-sensor, regime-switching Kalman filter to learn a latent process that captures dependencies between nearby stations and handles sharp changes in snowfall rate. Since the latent process is inferred using observations across working stations in the network, it can be used to fill in large data gaps for a malfunctioning station. The procedure was tested on meteorological and snow data from Wireless Sensor Networks (WSN) in the American River basin of the Sierra Nevada. Data include air temperature, relative humidity, and snow depth from dense networks of 10 to 12 stations within 1 km2 swaths. Both wet and dry water years have similar data issues. Data with artificially created gaps was used to quantify the method's performance. Our multi-sensor approach performs better than a single-sensor one, especially with large data gaps, as it learns and exploits the dominant underlying processes in snowpack at each site.
49 CFR 236.817 - Switch, electro-pneumatic.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 49 Transportation 4 2013-10-01 2013-10-01 false Switch, electro-pneumatic. 236.817 Section 236.817 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION... Switch, electro-pneumatic. A switch operated by an electro-pneumatic switch-and-lock movement. ...
49 CFR 236.817 - Switch, electro-pneumatic.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 49 Transportation 4 2012-10-01 2012-10-01 false Switch, electro-pneumatic. 236.817 Section 236.817 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION... Switch, electro-pneumatic. A switch operated by an electro-pneumatic switch-and-lock movement. ...
49 CFR 236.817 - Switch, electro-pneumatic.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 49 Transportation 4 2010-10-01 2010-10-01 false Switch, electro-pneumatic. 236.817 Section 236.817 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION... Switch, electro-pneumatic. A switch operated by an electro-pneumatic switch-and-lock movement. ...
49 CFR 236.817 - Switch, electro-pneumatic.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 49 Transportation 4 2011-10-01 2011-10-01 false Switch, electro-pneumatic. 236.817 Section 236.817 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION... Switch, electro-pneumatic. A switch operated by an electro-pneumatic switch-and-lock movement. ...
49 CFR 236.817 - Switch, electro-pneumatic.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 49 Transportation 4 2014-10-01 2014-10-01 false Switch, electro-pneumatic. 236.817 Section 236.817 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION... Switch, electro-pneumatic. A switch operated by an electro-pneumatic switch-and-lock movement. ...
PNEUMATIC PUMP TEST FOR DESIGN OF SOIL VACUUM EXTRACTION
In-situ pneumatic pumping tests were performed to estimate the pneumatic permeability at a site containing soils contaminated with aviation gasoline. Determination of pneumatic permeability was necessary to evaluate soil-air discharge or pore volume exchange rates. Pressure propa...
NASA Astrophysics Data System (ADS)
Reckziegel, S.; Kreye, D.; Puegner, T.; Vogel, U.; Scholles, M.; Grillberger, C.; Fehse, K.
2009-02-01
In this paper we present an optoelectronic integrated circuit (OEIC) based on monolithic integration of organic lightemitting diodes (OLEDs) and CMOS technology. By the use of integrated circuits, photodetectors and highly efficient OLEDs on the same silicon chip, novel OEICs with combined sensors and actuating elements can be realized. The OLEDs are directly deposited on the CMOS top metal. The metal layer serves as OLED bottom electrode and determines the bright area. Furthermore, the area below the OLED electrodes can be used for integrated circuits. The monolithic integration of actuators, sensors and electronics on a common silicon substrate brings significant advantages in most sensory applications. The developed OEIC combines three different types of sensors: a reflective sensor, a color sensor and a particle flow sensor and is configured with an orange (597nm) emitting p-i-n OLED. We describe the architecture of such a monolithic OEIC and demonstrate a method to determine the velocity of a fluid being conveyed pneumatically in a transparent capillary. The integrated OLEDs illuminate the capillary with the flowing fluid. The fluid has a random reflection profile. Depending on the velocity and a random contrast difference, more or less light is reflected back to the substrate. The integrated photodiodes located at different fixed points detect the reflected light and using crosscorrelation, the velocity is calculated from the time in which contrast differences move over a fixed distance.
A Low-Cost Hand Trainer Device Based On Microcontroller Platform
NASA Astrophysics Data System (ADS)
Sabor, Muhammad Akmal Mohammad; Thamrin, Norashikin M.
2018-03-01
Conventionally, the rehabilitation equipment used in the hospital or recovery center to treat and train the muscle of the stroke patient is implementing the pneumatic or compressed air machine. The main problem caused by this equipment is that the arrangement of the machine is quite complex and the position of it has been locked and fixed, which can cause uncomfortable feeling to the patients throughout the recovery session. Furthermore, the harsh movement from the machine could harm the patient as it does not allow flexibility movement and the use of pneumatic actuator has increased the gripping force towards the patient which could hurt them. Therefore, the main aim of this paper is to propose the development of the Bionic Hand Trainer based on Arduino platform, for a low-cost solution for rehabilitation machine as well as allows flexibility and smooth hand movement for the patients during the healing process. The scope of this work is to replicate the structure of the hand only at the fingers structure that is the phalanges part, which inclusive the proximal, intermediate and distal of the fingers. In order to do this, a hand glove is designed by equipping with flex sensors at every finger and connected them to the Arduino platform. The movement of the hand will motorize the movement of the dummy hand that has been controlled by the servo motors, which have been equipped along the phalanges part. As a result, the bending flex sensors due to the movement of the fingers has doubled up the rotation of the servo motors to mimic this movement at the dummy hand. The voltage output from the bending sensors are ranging from 0 volt to 5 volts, which are suitable for low-cost hand trainer device implementation. Through this system, the patient will have the power to control their gripping operation slowly without having a painful force from the external actuators throughout the rehabilitation process.
Hall effect sensors embedded within two-pole toothless stator assembly
NASA Technical Reports Server (NTRS)
Denk, Joseph (Inventor); Grant, Richard J. (Inventor)
1994-01-01
A two-pole toothless PM machine employs Hall effect sensors to indicate the position of the machine's rotor relative to power windings in the machine's stator. The Hall effect sensors are located in the main magnetic air gap underneath the power windings. The main magnetic air gap is defined by an outer magnetic surface of the rotor and an inner surface of the stator's flux collector ring.
Can We Really "Feel" a Balanced Total Knee Arthroplasty?
Elmallah, Randa K; Mistry, Jaydev B; Cherian, Jeffrey J; Chughtai, Morad; Bhave, Anil; Roche, Martin W; Mont, Michael A
2016-09-01
Balancing techniques in total knee arthroplasty are often based on surgeons' subjective judgment. However, newer technologies have allowed for objective measurements of soft tissue balancing. This study compared the use of sensor technology to the 30-year surgeon experience regarding (1) compartment loads, (2) soft tissue releases, and (3) component rotational alignments. Patients received either sensor-guided soft tissue balancing (n = 10) or manual gap balancing (n = 12). Wireless, intraoperative sensor tibial inserts were used to measure intracompartmental loads. The surgeon was blinded to values in the manual gap-balancing cohort. In the sensor cohort, the surgeon was unblinded, and implant trials were placed after normal releases were performed to guide further ligament releases after femoral and tibial resections, as needed. Load measurements were taken at 10°, 45°, and 90°. The sensor cohort had lower medial and lateral compartment loading at 10°, 45°, and 90°. The sensor group had lower mean differences in intercompartment loading at 10° (-5.6 vs -51.7 lbs), 45° (-9.8 vs -45.9 lbs), and 90° (-4.3 vs -27 lbs) compared to manually balanced patients. There were 10 additional soft tissue releases in the sensor cohort (2 initial ones before sensor use), compared to 2 releases in the gap-balanced cohort. In the gap-balanced cohort, tibial trays were positioned at a mean 9° external rotation, compared to a mean 1° internal rotation in the sensor-guided cohort. Sensor-balanced total knee arthroplasties provide objective feedback to perform releases and potentially improve knee balancing and rotational alignment. Future work may clarify whether these changes are beneficial for our patients. Copyright © 2016 Elsevier Inc. All rights reserved.
Improving dynamic performances of PWM-driven servo-pneumatic systems via a novel pneumatic circuit.
Taghizadeh, Mostafa; Ghaffari, Ali; Najafi, Farid
2009-10-01
In this paper, the effect of pneumatic circuit design on the input-output behavior of PWM-driven servo-pneumatic systems is investigated and their control performances are improved using linear controllers instead of complex and costly nonlinear ones. Generally, servo-pneumatic systems are well known for their nonlinear behavior. However, PWM-driven servo-pneumatic systems have the advantage of flexibility in the design of pneumatic circuits which affects the input-output linearity of the whole system. A simple pneumatic circuit with only one fast switching valve is designed which leads to a quasi-linear input-output relation. The quasi-linear behavior of the proposed circuit is verified both experimentally and by simulations. Closed loop position control experiments are then carried out using linear P- and PD-controllers. Since the output position is noisy and cannot be directly differentiated, a Kalman filter is designed to estimate the velocity of the cylinder. Highly improved tracking performances are obtained using these linear controllers, compared to previous works with nonlinear controllers.
Parameter tuning method for dither compensation of a pneumatic proportional valve with friction
NASA Astrophysics Data System (ADS)
Wang, Tao; Song, Yang; Huang, Leisheng; Fan, Wei
2016-05-01
In the practical application of pneumatic control devices, the nonlinearity of a pneumatic control valve become the main factor affecting the control effect, which comes mainly from the dynamic friction force. The dynamic friction inside the valve may cause hysteresis and a dead zone. In this paper, a dither compensation mechanism is proposed to reduce negative effects on the basis of analyzing the mechanism of friction force. The specific dither signal (using a sinusoidal signal) was superimposed on the control signal of the valve. Based on the relationship between the parameters of the dither signal and the inherent characteristics of the proportional servo valve, a parameter tuning method was proposed, which uses a displacement sensor to measure the maximum static friction inside the valve. According to the experimental results, the proper amplitude ranges are determined for different pressures. In order to get the optimal parameters of the dither signal, some dither compensation experiments have been carried out on different signal amplitude and gas pressure conditions. Optimal parameters are determined under two kinds of pressure conditions. Using tuning parameters the valve spool displacement experiment has been taken. From the experiment results, hysteresis of the proportional servo valve is significantly reduced. And through simulation and experiments, the cut-off frequency of the proportional valve has also been widened. Therefore after adding the dither signal, the static and dynamic characteristics of the proportional valve are both improved to a certain degree. This research proposes a parameter tuning method of dither signal, and the validity of the method is verified experimentally.
Fabrication and Characterization of a Nanocoax-Based Electrochemical Sensor
NASA Astrophysics Data System (ADS)
Rizal, Binod; Archibald, Michelle M.; Naughton, Jeffrey R.; Connolly, Timothy; Shepard, Stephen C.; Burns, Michael J.; Chiles, Thomas C.; Naughton, Michael J.
2014-03-01
We used an imprint lithography process to fabricate three dimensional electrochemical sensors comprising arrays of vertically-oriented coaxial electrodes, with the coax cores and shields serving as working and counter electrodes, respectively, and with nanoscale separation gaps.[2] Arrays of devices with different electrode gaps (coax annuli) were prepared, yielding increasing sensitivity with decreasing annulus thickness. A coax-based sensor with a 100 nm annulus was found to have sensitivity 100 times greater than that of a conventional planar sensor control, which had millimeter-scale electrode gap spacing. We suggest that this enhancement is due to an increase in the diffusion of molecules between electrodes, which improves the current per unit surface area compared to the planar device. Supported by NIH (National Cancer Institute and the National Institute of Allergy and Infectious Diseases).
49 CFR 571.117 - Standard No. 117; Retreaded pneumatic tires.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 49 Transportation 6 2010-10-01 2010-10-01 false Standard No. 117; Retreaded pneumatic tires. 571... Federal Motor Vehicle Safety Standards § 571.117 Standard No. 117; Retreaded pneumatic tires. S1. Scope. This standard specifies performance, labeling, and certification requirements for retreaded pneumatic...
49 CFR 236.590 - Pneumatic apparatus.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 49 Transportation 4 2010-10-01 2010-10-01 false Pneumatic apparatus. 236.590 Section 236.590..., Train Control and Cab Signal Systems Inspection and Tests; Locomotive § 236.590 Pneumatic apparatus. Automatic train stop, train control, or cab signal pneumatic apparatus shall be inspected, cleaned, and the...
49 CFR 236.590 - Pneumatic apparatus.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 49 Transportation 4 2011-10-01 2011-10-01 false Pneumatic apparatus. 236.590 Section 236.590..., Train Control and Cab Signal Systems Inspection and Tests; Locomotive § 236.590 Pneumatic apparatus. Automatic train stop, train control, or cab signal pneumatic apparatus shall be inspected, cleaned, and the...
NASA Technical Reports Server (NTRS)
Holanda, Raymond; Kim, Walter S.; Pencil, Eric; Groth, Mary; Danzey, Gerald A.
1990-01-01
Parallel gap resistance welding was used to attach lead wires to sputtered thin film sensors. Ranges of optimum welding parameters to produce an acceptable weld were determined. The thin film sensors were Pt13Rh/Pt thermocouples; they were mounted on substrates of MCrAlY-coated superalloys, aluminum oxide, silicon carbide and silicon nitride. The entire sensor system is designed to be used on aircraft engine parts. These sensor systems, including the thin-film-to-lead-wire connectors, were tested to 1000 C.
21 CFR 882.4370 - Pneumatic cranial drill motor.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Pneumatic cranial drill motor. 882.4370 Section... drill motor. (a) Identification. A pneumatic cranial drill motor is a pneumatically operated power source used with removable rotating surgical cutting tools or drill bits on a patient's skull. (b...
21 CFR 882.4370 - Pneumatic cranial drill motor.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Pneumatic cranial drill motor. 882.4370 Section... drill motor. (a) Identification. A pneumatic cranial drill motor is a pneumatically operated power source used with removable rotating surgical cutting tools or drill bits on a patient's skull. (b...
21 CFR 882.4370 - Pneumatic cranial drill motor.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Pneumatic cranial drill motor. 882.4370 Section... drill motor. (a) Identification. A pneumatic cranial drill motor is a pneumatically operated power source used with removable rotating surgical cutting tools or drill bits on a patient's skull. (b...
14 CFR 23.1416 - Pneumatic de-icer boot system.
Code of Federal Regulations, 2012 CFR
2012-01-01
... Safety Equipment § 23.1416 Pneumatic de-icer boot system. If certification with ice protection provisions is desired and a pneumatic de-icer boot system is installed— (a) The system must meet the... 14 Aeronautics and Space 1 2012-01-01 2012-01-01 false Pneumatic de-icer boot system. 23.1416...
14 CFR 23.1416 - Pneumatic de-icer boot system.
Code of Federal Regulations, 2014 CFR
2014-01-01
... Safety Equipment § 23.1416 Pneumatic de-icer boot system. If certification with ice protection provisions is desired and a pneumatic de-icer boot system is installed— (a) The system must meet the... 14 Aeronautics and Space 1 2014-01-01 2014-01-01 false Pneumatic de-icer boot system. 23.1416...
14 CFR 23.1416 - Pneumatic de-icer boot system.
Code of Federal Regulations, 2013 CFR
2013-01-01
... Safety Equipment § 23.1416 Pneumatic de-icer boot system. If certification with ice protection provisions is desired and a pneumatic de-icer boot system is installed— (a) The system must meet the... 14 Aeronautics and Space 1 2013-01-01 2013-01-01 false Pneumatic de-icer boot system. 23.1416...
14 CFR 23.1416 - Pneumatic de-icer boot system.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Pneumatic de-icer boot system. 23.1416... Safety Equipment § 23.1416 Pneumatic de-icer boot system. If certification with ice protection provisions is desired and a pneumatic de-icer boot system is installed— (a) The system must meet the...
14 CFR 23.1416 - Pneumatic de-icer boot system.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Pneumatic de-icer boot system. 23.1416... Safety Equipment § 23.1416 Pneumatic de-icer boot system. If certification with ice protection provisions is desired and a pneumatic de-icer boot system is installed— (a) The system must meet the...
Fabrication of a printed capacitive air-gap touch sensor
NASA Astrophysics Data System (ADS)
Lee, Sang Hoon; Seo, Hwiwon; Lee, Sangyoon
2018-05-01
Unlike lithography-based processes, printed electronics does not require etching, which makes it difficult to fabricate electronic devices with an air gap. In this study, we propose a method to fabricate capacitive air-gap touch sensors via printing and coating. First, the bottom electrode was fabricated on a flexible poly(ethylene terephthalate) (PET) substrate using roll-to-roll gravure printing with silver ink. Then poly(dimethylsiloxane) (PDMS) was spin coated to form a sacrificial layer. The top electrode was fabricated on the sacrificial layer by spin coating with a stretchable silver ink. The sensor samples were then put in a tetrabutylammonium (TBAF) bath to generate the air gap by removing the sacrificial layer. The capacitance of the samples was measured for verification, and the results show that the capacitance increases in proportion to the applied force from 0 to 2.5 N.
Continued Development and Improvement of Pneumatic Heavy Vehicles
DOE Office of Scientific and Technical Information (OSTI.GOV)
Robert J. Englar
2005-07-15
The objective of this applied research effort led by Georgia Tech Research Institute is the application of pneumatic aerodynamic technology previously developed and patented by us to the design of an appropriate Heavy Vehicle (HV) tractor-trailer configuration, and experimental confirmation of this pneumatic configuration's improved aerodynamic characteristics. In Phases I to IV of our previous DOE program (Reference 1), GTRI has developed, patented, wind-tunnel tested and road-tested blown aerodynamic devices for Pneumatic Heavy Vehicles (PHVs) and Pneumatic Sports Utility Vehicles (PSUVs). To further advance these pneumatic technologies towards HV and SUV applications, additional Phase V tasks were included in themore » first year of a continuing DOE program (Reference 2). Based on the results of the Phase IV full-scale test programs, these Phase V tasks extended the application of pneumatic aerodynamics to include: further economy and performance improvements; increased aerodynamic stability and control; and safety of operation of Pneumatic HVs. Continued development of a Pneumatic SUV was also conducted during the Phase V program. Phase V was completed in July, 2003; its positive results towards development and confirmation of this pneumatic technology are reported in References 3 and 4. The current Phase VI of this program was incrementally funded by DOE in order to continue this technology development towards a second fuel economy test on the Pneumatic Heavy Vehicle. The objectives of this current Phase VI research and development effort (Ref. 5) fall into two categories: (1) develop improved pneumatic aerodynamic technology and configurations on smaller-scale models of the advanced Pneumatic Heavy Vehicle (PHV); and based on these findings, (2) redesign, modify, and re-test the modified full-scale PHV test vehicle. This second objective includes conduct of an on-road preliminary road test of this configuration to prepare it for a second series of SAE Type-U fuel economy evaluations, as described in Ref. 5. Both objectives are based on the pneumatic technology already developed and confirmed for DOE OHVT/OAAT in Phases I-V. This new Phase VI effort was initiated by contract amendment to the Phase V effort using carryover FY02 funds. This were conducted under a new and distinct project number, GTRI Project A-6935, separate from the Phase I-IV program. However, the two programs are closely integrated, and thus Phase VI continues with the previous program and goals.« less
Colliding wall-jets on a cylindrical surface
NASA Astrophysics Data System (ADS)
Tesař, Václav; Peszynski, Kazimierz
2015-05-01
Paper discusses aerodynamics and potential engineering applications of an unusual and in literature practically unknown fluid flow configuration, with two wall-jets attached to a cylindrical surface so that they collide head-on and by mutual conjunction generate a single jet directed away from the wall. Applications are envisaged in pneumatic sensors, particularly those operating at low Reynolds numbers. Performed experimental investigation, combined with numerical flowfield computations, revealed several interesting aspects. The most interesting among them is the discovery of symmetry-breaking existence of three different stable flow regimes. This opens a possibility for fluidic tristable amplifiers and systems operating with ternary logic.
46 CFR 108.409 - Location and spacing of tubing in pneumatic fire detection system.
Code of Federal Regulations, 2010 CFR
2010-10-01
... detection system. 108.409 Section 108.409 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED... and spacing of tubing in pneumatic fire detection system. (a) All tubing in a pneumatic fire detection... exposed in the space. (c) A pneumatic fire detection system must be set to activate after approximately a...
46 CFR 56.97-35 - Pneumatic tests (replaces 137.5).
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 2 2012-10-01 2012-10-01 false Pneumatic tests (replaces 137.5). 56.97-35 Section 56.97-35 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING PIPING SYSTEMS AND APPURTENANCES Pressure Tests § 56.97-35 Pneumatic tests (replaces 137.5). (a) General Requirements. When a pneumatic test is performed, it...
46 CFR 54.10-15 - Pneumatic test (modifies UG-100).
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 2 2013-10-01 2013-10-01 false Pneumatic test (modifies UG-100). 54.10-15 Section 54.10-15 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING PRESSURE VESSELS Inspection, Reports, and Stamping § 54.10-15 Pneumatic test (modifies UG-100). (a) Pneumatic testing of welded pressure vessels shall be...
46 CFR 54.10-15 - Pneumatic test (modifies UG-100).
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 2 2012-10-01 2012-10-01 false Pneumatic test (modifies UG-100). 54.10-15 Section 54.10-15 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING PRESSURE VESSELS Inspection, Reports, and Stamping § 54.10-15 Pneumatic test (modifies UG-100). (a) Pneumatic testing of welded pressure vessels shall be...
46 CFR 54.10-15 - Pneumatic test (modifies UG-100).
Code of Federal Regulations, 2014 CFR
2014-10-01
... 46 Shipping 2 2014-10-01 2014-10-01 false Pneumatic test (modifies UG-100). 54.10-15 Section 54.10-15 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING PRESSURE VESSELS Inspection, Reports, and Stamping § 54.10-15 Pneumatic test (modifies UG-100). (a) Pneumatic testing of welded pressure vessels shall be...
Networked sensors for the combat forces
NASA Astrophysics Data System (ADS)
Klager, Gene
2004-11-01
Real-time and detailed information is critical to the success of ground combat forces. Current manned reconnaissance, surveillance, and target acquisition (RSTA) capabilities are not sufficient to cover battlefield intelligence gaps, provide Beyond-Line-of-Sight (BLOS) targeting, and the ambush avoidance information necessary for combat forces operating in hostile situations, complex terrain, and conducting military operations in urban terrain. This paper describes a current US Army program developing advanced networked unmanned/unattended sensor systems to survey these gaps and provide the Commander with real-time, pertinent information. Networked Sensors for the Combat Forces plans to develop and demonstrate a new generation of low cost distributed unmanned sensor systems organic to the RSTA Element. Networked unmanned sensors will provide remote monitoring of gaps, will increase a unit"s area of coverage, and will provide the commander organic assets to complete his Battlefield Situational Awareness (BSA) picture for direct and indirect fire weapons, early warning, and threat avoidance. Current efforts include developing sensor packages for unmanned ground vehicles, small unmanned aerial vehicles, and unattended ground sensors using advanced sensor technologies. These sensors will be integrated with robust networked communications and Battle Command tools for mission planning, intelligence "reachback", and sensor data management. The network architecture design is based on a model that identifies a three-part modular design: 1) standardized sensor message protocols, 2) Sensor Data Management, and 3) Service Oriented Architecture. This simple model provides maximum flexibility for data exchange, information management and distribution. Products include: Sensor suites optimized for unmanned platforms, stationary and mobile versions of the Sensor Data Management Center, Battle Command planning tools, networked communications, and sensor management software. Details of these products and recent test results will be presented.
The effect of pneumatic dilation in management of postfundoplication dysphagia.
Sunjaya, D; Podboy, A; Blackmon, S H; Katzka, D; Halland, M
2017-06-01
Fundoplication surgery is a commonly performed procedure for gastro-esophageal reflux disease or hiatal hernia repair. Up to 10% of patients develop persistent postoperative dysphagia after surgery. Data on the effectiveness of pneumatic dilation for treatment are limited. The aim of this study was to evaluate clinical outcomes and identify clinical factors associated with successful response to pneumatic dilation among patients with persistent postfundoplication dysphagia (PPFD). We retrospectively evaluated patients who had undergone pneumatic dilation for PPFD between 1999 and 2016. Patients with dysphagia or achalasia prior to fundoplication were excluded. Demographic information, surgical history, severity of dysphagia, and clinical outcomes were collected. Data pertaining to esophagram, manometry, endoscopy, and pneumatic dilation were also collected. We identified 38 patients (82% female, 95% Caucasian, and median age 59 years) with PPFD who completed pneumatic dilation. The median postfundoplication dysphagia score was 2. Eleven patients had abnormal peristalsis on manometry. Seventeen patients reported response (seven complete) with an average decrease of 1 in their dysphagia score. Fifteen patients underwent reoperation due to PPFD. Hiatal hernia repair was the only factor that predicts a higher response rate to pneumatic dilation. Only one patient in our study developed complication (pneumoperitoneum) from pneumatic dilation. We found that pneumatic dilation to be a safe treatment option for PPFD with moderate efficacy. Patients who developed PPFD after a hiatal hernia repair may gain the greatest benefit after pneumatic dilation. We were not able to identify additional clinical, radiological, endoscopic, or manometric parameters that were predictive of response. © 2017 John Wiley & Sons Ltd.
Dynamic Friction Performance of a Pneumatic Cylinder with Al2O3 Film on Cylinder Surface.
Chang, Ho; Lan, Chou-Wei; Wang, Hao-Xian
2015-11-01
A friction force system is proposed for accurately measuring friction force and motion properties produced by reciprocating motion of piston in a pneumatic cylinder. In this study, the proposed system is used to measure the effects of lubricating greases of different viscosities on the friction properties of pneumatic cylinder, and improvement of stick-slip motion for the cylinder bore by anodizing processes. A servo motor-driven ball screw is used to drive the pneumatic cylinder to be tested and to measure the change in friction force of the pneumatic cylinder. Experimental results show, that under similar test conditions, the lubricating grease with viscosity VG100 is best suited for measuring reciprocating motion of the piston of pneumatic cylinder. The wear experiment showed that, in the Al2O3 film obtained at a preset voltage 40 V in the anodic process, the friction coefficient and hardness decreased by 55% and increased by 274% respectively, thus achieving a good tribology and wear resistance. Additionally, the amplitude variation in the friction force of the pneumatic cylinder wall that received the anodizing treatment was substantially reduced. Additionally, the stick-slip motion of the pneumatic cylinder during low-speed motion was substantially improved.
Rhee, Minsoung
2010-01-01
We have developed pneumatic logic circuits and microprocessors built with microfluidic channels and valves in polydimethylsiloxane (PDMS). The pneumatic logic circuits perform various combinational and sequential logic calculations with binary pneumatic signals (atmosphere and vacuum), producing cascadable outputs based on Boolean operations. A complex microprocessor is constructed from combinations of various logic circuits and receives pneumatically encoded serial commands at a single input line. The device then decodes the temporal command sequence by spatial parallelization, computes necessary logic calculations between parallelized command bits, stores command information for signal transportation and maintenance, and finally executes the command for the target devices. Thus, such pneumatic microprocessors will function as a universal on-chip control platform to perform complex parallel operations for large-scale integrated microfluidic devices. To demonstrate the working principles, we have built 2-bit, 3-bit, 4-bit, and 8-bit microprecessors to control various target devices for applications such as four color dye mixing, and multiplexed channel fluidic control. By significantly reducing the need for external controllers, the digital pneumatic microprocessor can be used as a universal on-chip platform to autonomously manipulate microfluids in a high throughput manner. PMID:19823730
Treatments for pediatric achalasia: Heller myotomy or pneumatic dilatation?
Jung, C; Michaud, L; Mougenot, J-F; Lamblin, M-D; Philippe-Chomette, P; Cargill, G; Bonnevalle, M; Boige, N; Bellaïche, M; Viala, J; Hugot, J-P; Gottrand, F; Cezard, J-P
2010-03-01
The treatment of achalasia consists of reducing distal esophageal obstruction by either Heller myotomy surgery or endoscopic pneumatic dilatation. The aim of the present study was to evaluate the short- and middle-term results of these procedures in children. For technical reasons, children under six years old (n=8) were treated by surgery only, whereas patients over six years old (n=14) were treated by either Heller myotomy or pneumatic dilatation. Of the children aged under six years, 75% were symptom-free at six months and 83% at 24 months of follow-up. Of the patients aged over six years, complete remission was achieved by Heller myotomy in 44.5% vs. 55.5% by pneumatic dilatation after six months, and in 40% vs. 65%, respectively, after 24 months. Both pneumatic dilatation and Heller myotomy showed significant rates of failure. These results suggest that pneumatic dilatation may be considered a primary treatment in children over six years old. Also, where necessary, Heller myotomy and pneumatic dilatation may be used as complementary treatments.
[Morphine self-administration by rats using a pneumatic syringe].
Akiyama, Y; Takayama, S
1988-06-01
An apparatus for drug self-administration by rats using a pneumatic syringe was developed by Weeks. A microliter syringe operated by a pneumatic cylinder supplies an accurate volume of drug solution within one second. When coefficient of variation of infusion volume was compared among pneumatic syringe, infusion pump, and peristaltic pump, pneumatic syringe showed higher accuracy in infusion volume than the other two pumps. Since the infusion speed by a pneumatic syringe is very rapid (less than one second per infusion), the effect of infusion speed on reinforcing property of morphine was investigated. When rats self-administered 0.1, 0.3, 1.0, and 3.0 mg/kg/infusion of morphine by pneumatic syringes, the patterns of self-infusion were more stable, the number of self-infusions and the amount self-administered were larger, and a dose-response relationship was clearer in comparison with those self-infused the same doses of morphine for 5.6 seconds by infusion pumps or peristaltic pumps.
Key issues in theoretical and functional pneumatic design
NASA Astrophysics Data System (ADS)
Xu, Z. G.; Yang, D. Y.; Liu, W. M.; Liu, T. T.
2017-10-01
This paper studies the energy release of the pneumatic engine in different thermodynamic processes, the isothermal process is the highest power output process, while adiabatic process is the lowest energy output process, and the energy release of the pneumatic engine is a multi-state thermodynamic process between them. Therefore heat exchanging should be increased between the pneumatic engine and the outer space, the gas expansion process in the cylinder should be as close as possible to the isothermal process. Heat exchange should be increased between the cylinder and the external spaces. Secondly, the fin structure is studied to increase the heat exchanging between the cylinder body and the outside space. The upper part has fin structures and the lower cylinder has no fin structure, this structure improved the working efficiency of pneumatic engine. Finally the cam and the hydraulic bottle of pneumatic engines are designed. Simulation and theoretical calculation are used to the analysis of the whole structure, which lay the foundation for the manufacturing and design of the pneumatic engines.
Effect of electrode gap on the sensing properties of multiwalled carbon nanotubes based gas sensor
NASA Astrophysics Data System (ADS)
Saheed, Mohamed Shuaib Mohamed; Mohamed, Norani Muti; Burhanudin, Zainal Arif
2016-11-01
Vertically aligned multiwalled carbon nanotubes (MWCNT) were grown on Si substrate coated with alumina and iron using chemical vapor deposition. Electrode gap of 10, 25 and 50 µm were adopted to determine the effect of varying gap spacing on the sensing properties such as voltage breakdown, sensitivity and selectivity for three gases namely argon, carbon dioxide and ammonia. Argon has the lowest voltage breakdown for every electrode gap. The fabricated MWCNT based gas sensor drastically reduced the voltage breakdown by 89.5% when the electrode spacing is reduced from 50 µm to 10 µm. The reduction is attributed to the high non-uniform electric field between the electrodes caused by the protrusion of nanotips. The sensor shows good sensitivity and selectivity with the ability to detect the gas in the mixture with air provided that the concentration is ≥ 20% where the voltage breakdown will be close to the pure gas.
A Study of Gas Economizing Pneumatic Cylinder
NASA Astrophysics Data System (ADS)
Li, T. C.; Wu, H. W.; Kuo, M. J.
2006-10-01
The pneumatic cylinder is the most typical actuator in the pneumatic equipment, and its mechanism is so simple that it is often used to operate point to point driving without the feedback loop in various automatic machines. But, the energy efficiency of pneumatic system is very poor compared with electrical systems and hydraulic systems. So, it is very important to discuss the energy saving for the pneumatic cylinder systems. In this thesis, we proposed three methods to apply the reduction in the air consumed for pneumatic cylinder systems. An air charge accumulator is used to absorb the exhausted compress air and a boost valve boosted the air to the higher pressure for used again. From the experiments, the direct used cylinder exhaust air may save about 40% of compress air.
Chemically modulated graphene quantum dot for tuning the photoluminescence as novel sensory probe
NASA Astrophysics Data System (ADS)
Hwang, Eunhee; Hwang, Hee Min; Shin, Yonghun; Yoon, Yeoheung; Lee, Hanleem; Yang, Junghee; Bak, Sora; Lee, Hyoyoung
2016-12-01
A band gap tuning of environmental-friendly graphene quantum dot (GQD) becomes a keen interest for novel applications such as photoluminescence (PL) sensor. Here, for tuning the band gap of GQD, a hexafluorohydroxypropanyl benzene (HFHPB) group acted as a receptor of a chemical warfare agent was chemically attached on the GQD via the diazonium coupling reaction of HFHPB diazonium salt, providing new HFHPB-GQD material. With a help of the electron withdrawing HFHPB group, the energy band gap of the HFHPB-GQD was widened and its PL decay life time decreased. As designed, after addition of dimethyl methyl phosphonate (DMMP), the PL intensity of HFHPB-GQD sensor sharply increased up to approximately 200% through a hydrogen bond with DMMP. The fast response and short recovery time was proven by quartz crystal microbalance (QCM) analysis. This HFHPB-GQD sensor shows highly sensitive to DMMP in comparison with GQD sensor without HFHPB and graphene. In addition, the HFHPB-GQD sensor showed high selectivity only to the phosphonate functional group among many other analytes and also stable enough for real device applications. Thus, the tuning of the band gap of the photoluminescent GQDs may open up new promising strategies for the molecular detection of target substrates.
Chemically modulated graphene quantum dot for tuning the photoluminescence as novel sensory probe
Hwang, Eunhee; Hwang, Hee Min; Shin, Yonghun; Yoon, Yeoheung; Lee, Hanleem; Yang, Junghee; Bak, Sora; Lee, Hyoyoung
2016-01-01
A band gap tuning of environmental-friendly graphene quantum dot (GQD) becomes a keen interest for novel applications such as photoluminescence (PL) sensor. Here, for tuning the band gap of GQD, a hexafluorohydroxypropanyl benzene (HFHPB) group acted as a receptor of a chemical warfare agent was chemically attached on the GQD via the diazonium coupling reaction of HFHPB diazonium salt, providing new HFHPB-GQD material. With a help of the electron withdrawing HFHPB group, the energy band gap of the HFHPB-GQD was widened and its PL decay life time decreased. As designed, after addition of dimethyl methyl phosphonate (DMMP), the PL intensity of HFHPB-GQD sensor sharply increased up to approximately 200% through a hydrogen bond with DMMP. The fast response and short recovery time was proven by quartz crystal microbalance (QCM) analysis. This HFHPB-GQD sensor shows highly sensitive to DMMP in comparison with GQD sensor without HFHPB and graphene. In addition, the HFHPB-GQD sensor showed high selectivity only to the phosphonate functional group among many other analytes and also stable enough for real device applications. Thus, the tuning of the band gap of the photoluminescent GQDs may open up new promising strategies for the molecular detection of target substrates. PMID:27991584
Experimental research of flow servo-valve
NASA Astrophysics Data System (ADS)
Takosoglu, Jakub
Positional control of pneumatic drives is particularly important in pneumatic systems. Some methods of positioning pneumatic cylinders for changeover and tracking control are known. Choking method is the most development-oriented and has the greatest potential. An optimal and effective method, particularly when applied to pneumatic drives, has been searched for a long time. Sophisticated control systems with algorithms utilizing artificial intelligence methods are designed therefor. In order to design the control algorithm, knowledge about real parameters of servo-valves used in control systems of electro-pneumatic servo-drives is required. The paper presents the experimental research of flow servo-valve.
Optimizing pneumatic conveying of biomass materials
NASA Astrophysics Data System (ADS)
DiCianni, Matthew Edward Michael
2011-12-01
Biomass is a readily available but underutilized energy resource. One of the main challenges is the inability of biomass feed stocks like corn stover or wood chips to flow freely without intermittent jamming. This research integrated an automated pneumatic conveying system to efficiently transport biomass into a biomass reactor. Material was held in a storage container until an end effector attached to a 3-axis controller engaged the material to flow through pneumatic vacuum in the carrier fluid of air. The material was disengaged from the carrier fluid through centripetal forces induced by a cyclone separator. As the air was pulled out of the cyclone, the biomass drops out the bottom due to gravitational forces and fell into a secondary storage hopper. The second storage container was for testing purposes only, where the actual apparatus would use a vertically oriented lock hopper to feed material into the biomass reactor. In the experimental test apparatus, sensors measured the storage hopper weight (mass-flow rate), pressure drop from the blower, and input power consumption of the motor. Parameters that were adjusted during testing include pipe diameter, material type, and motor speed. Testing indicated that decreasing the motor speed below its maximum still allows for conveyance of the material without blockage forming in the piping. The data shows that the power consumption of the system can be reduced based on the size and weight of the material introduced to the conveying pipe. Also, conveying certain materials proved to be problematic with particular duct diameters. Ultimately, an optimal duct diameter that can perform efficiently for a broad range of materials was chosen for the given system. Through these improvements, the energy return on investment will be improved for biomass feed stocks, which is taking a step in the right direction to secure the nation's energy independence.
Won, Jungeun; Monroy, Guillermo L; Huang, Pin-Chieh; Dsouza, Roshan; Hill, Malcolm C; Novak, Michael A; Porter, Ryan G; Chaney, Eric; Barkalifa, Ronit; Boppart, Stephen A
2018-02-01
Pneumatic otoscopy to assess the mobility of the tympanic membrane (TM) is a highly recommended diagnostic method of otitis media (OM), a widespread middle ear infection characterized by the fluid accumulation in the middle ear. Nonetheless, limited depth perception and subjective interpretation of small TM displacements have challenged the appropriate and efficient examination of TM dynamics experienced during OM. In this paper, a pneumatic otoscope integrated with low coherence interferometry (LCI) was adapted with a controlled pressure-generating system to record the pneumatic response of the TM and to estimate middle ear pressure (MEP). Forty-two ears diagnosed as normal (n = 25), with OM (n = 10), or associated with an upper respiratory infection (URI) (n = 7) were imaged with a pneumatic LCI otoscope with an axial, transverse, and temporal resolution of 6 µm, 20 µm, and 1 msec, respectively. The TM displacement under pneumatic pressure transients (a duration of 0.5 sec with an intensity of ± 150 daPa) was measured to compute two metrics (compliance and amplitude ratio). These metrics were correlated with peak acoustic admittance and MEP from tympanometry and statistically compared via Welch's t- test. As a result, the compliance represents pneumatic TM mobility, and the amplitude ratio estimates MEP. The presence of a middle ear effusion (MEE) significantly decreased compliance (p<0.001). The amplitude ratio of the OM group was statistically less than that of the normal group (p<0.01), indicating positive MEP. Unlike tympanometry, pneumatic LCI otoscopy quantifies TM mobility as well as MEP regardless of MEE presence. With combined benefits of pneumatic otoscopy and tympanometry, pneumatic LCI otoscopy may provide new quantitative metrics for understanding TM dynamics and diagnosing OM.
Won, Jungeun; Monroy, Guillermo L.; Huang, Pin-Chieh; Dsouza, Roshan; Hill, Malcolm C.; Novak, Michael A.; Porter, Ryan G.; Chaney, Eric; Barkalifa, Ronit; Boppart, Stephen A.
2018-01-01
Pneumatic otoscopy to assess the mobility of the tympanic membrane (TM) is a highly recommended diagnostic method of otitis media (OM), a widespread middle ear infection characterized by the fluid accumulation in the middle ear. Nonetheless, limited depth perception and subjective interpretation of small TM displacements have challenged the appropriate and efficient examination of TM dynamics experienced during OM. In this paper, a pneumatic otoscope integrated with low coherence interferometry (LCI) was adapted with a controlled pressure-generating system to record the pneumatic response of the TM and to estimate middle ear pressure (MEP). Forty-two ears diagnosed as normal (n = 25), with OM (n = 10), or associated with an upper respiratory infection (URI) (n = 7) were imaged with a pneumatic LCI otoscope with an axial, transverse, and temporal resolution of 6 µm, 20 µm, and 1 msec, respectively. The TM displacement under pneumatic pressure transients (a duration of 0.5 sec with an intensity of ± 150 daPa) was measured to compute two metrics (compliance and amplitude ratio). These metrics were correlated with peak acoustic admittance and MEP from tympanometry and statistically compared via Welch’s t-test. As a result, the compliance represents pneumatic TM mobility, and the amplitude ratio estimates MEP. The presence of a middle ear effusion (MEE) significantly decreased compliance (p<0.001). The amplitude ratio of the OM group was statistically less than that of the normal group (p<0.01), indicating positive MEP. Unlike tympanometry, pneumatic LCI otoscopy quantifies TM mobility as well as MEP regardless of MEE presence. With combined benefits of pneumatic otoscopy and tympanometry, pneumatic LCI otoscopy may provide new quantitative metrics for understanding TM dynamics and diagnosing OM. PMID:29552381
NASA Astrophysics Data System (ADS)
Chen, Yung-Yu; Huang, Li-Chung; Wang, Wei-Shan; Lin, Yu-Ching; Wu, Tsung-Tsong; Sun, Jia-Hong; Esashi, Masayoshi
2013-04-01
Acoustic interference suppression of quartz crystal microbalance (QCM) sensor arrays utilizing phononic crystals is investigated in this paper. A square-lattice phononic crystal structure is designed to have a complete band gap covering the QCM's resonance frequency. The monolithic sensor array consisting of two QCMs separated by phononic crystals is fabricated by micromachining processes. As a result, 12 rows of phononic crystals with band gap boost insertion loss between the two QCMs by 20 dB and also reduce spurious modes. Accordingly, the phononic crystal is verified to be capable of suppressing the acoustic interference between adjacent QCMs in a sensor array.
Control of soft machines using actuators operated by a Braille display.
Mosadegh, Bobak; Mazzeo, Aaron D; Shepherd, Robert F; Morin, Stephen A; Gupta, Unmukt; Sani, Idin Zhalehdoust; Lai, David; Takayama, Shuichi; Whitesides, George M
2014-01-07
One strategy for actuating soft machines (e.g., tentacles, grippers, and simple walkers) uses pneumatic inflation of networks of small channels in an elastomeric material. Although the management of a few pneumatic inputs and valves to control pressurized gas is straightforward, the fabrication and operation of manifolds containing many (>50) independent valves is an unsolved problem. Complex pneumatic manifolds-often built for a single purpose-are not easily reconfigured to accommodate the specific inputs (i.e., multiplexing of many fluids, ranges of pressures, and changes in flow rates) required by pneumatic systems. This paper describes a pneumatic manifold comprising a computer-controlled Braille display and a micropneumatic device. The Braille display provides a compact array of 64 piezoelectric actuators that actively close and open elastomeric valves of a micropneumatic device to route pressurized gas within the manifold. The positioning and geometries of the valves and channels in the micropneumatic device dictate the functionality of the pneumatic manifold, and the use of multi-layer soft lithography permits the fabrication of networks in a wide range of configurations with many possible functions. Simply exchanging micropneumatic devices of different designs enables rapid reconfiguration of the pneumatic manifold. As a proof of principle, a pneumatic manifold controlled a soft machine containing 32 independent actuators to move a ball above a flat surface.
Control of Soft Machines using Actuators Operated by a Braille Display
Mosadegh, Bobak; Mazzeo, Aaron D.; Shepherd, Robert F.; Morin, Stephen A.; Gupta, Unmukt; Sani, Idin Zhalehdoust; Lai, David; Takayama, Shuichi; Whitesides, George M.
2013-01-01
One strategy for actuating soft machines (e.g., tentacles, grippers, and simple walkers) uses pneumatic inflation of networks of small channels in an elastomeric material. Although the management of a few pneumatic inputs and valves to control pressurized gas is straightforward, the fabrication and operation of manifolds containing many (>50) independent valves is an unsolved problem. Complex pneumatic manifolds—often built for a single purpose—are not easily reconfigured to accommodate the specific inputs (i.e., multiplexing of many fluids, ranges of pressures, and changes in flow rates) required by pneumatic systems. This paper describes a pneumatic manifold comprising a computer-controlled braille display and a micropneumatic device. The braille display provides a compact array of 64 piezoelectric actuators that actively close and open elastomeric valves of a micropneumatic device to route pressurized gas within the manifold. The positioning and geometries of the valves and channels in the micropneumatic device dictate the functionality of the pneumatic manifold, and the use of multi-layer soft lithography permits the fabrication of networks in a wide range of configurations with many possible functions. Simply exchanging micropneumatic devices of different designs enables rapid reconfiguration of the pneumatic manifold. As a proof of principle, a pneumatic manifold controlled a soft machine containing 32 independent actuators to move a ball above a flat surface. PMID:24196070
[Modern pneumatic weapons and injuries they cause].
Kozachenko, I N
2013-01-01
The data on the history of development and further improvement of pneumatic weapons are presented with special reference to specific features of different types and varieties of these weapons, cartridges for them, and the sphere of their application. Investigations into peculiarities of damages caused by high-capacity pneumatic weapons to the objects of forensic medical expertise affected from different distances are reviewed. Results of forensic medical expertise and clinical studies on the structure of body injuries inflicted by gunshots from pneumatic weapons to the human body are discussed. The author emphasizes the necessity of developing up-to-date terminology and classification of gunshot injuries caused by shooting from pneumatic weapons.
Method of sections in analytical calculations of pneumatic tires
NASA Astrophysics Data System (ADS)
Tarasov, V. N.; Boyarkina, I. V.
2018-01-01
Analytical calculations in the pneumatic tire theory are more preferable in comparison with experimental methods. The method of section of a pneumatic tire shell allows to obtain equations of intensities of internal forces in carcass elements and bead rings. Analytical dependencies of intensity of distributed forces have been obtained in tire equator points, on side walls (poles) and pneumatic tire bead rings. Along with planes in the capacity of secant surfaces cylindrical surfaces are used for the first time together with secant planes. The tire capacity equation has been obtained using the method of section, by means of which a contact body is cut off from the tire carcass along the contact perimeter by the surface which is normal to the bearing surface. It has been established that the Laplace equation for the solution of tasks of this class of pneumatic tires contains two unknown values that requires the generation of additional equations. The developed computational schemes of pneumatic tire sections and new equations allow to accelerate the pneumatic tire structure improvement process during engineering.
Development of pneumatic actuator with low-wave reflection characteristics
NASA Astrophysics Data System (ADS)
Chang, H.; Tsung, T. T.; Jwo, C. S.; Chiang, J. C.
2010-08-01
This study aims at the development of a less reflective electromagnetic pneumatic actuator often used in the anechoic chamber. Because a pneumatic actuator on the market is not appropriate for use in such a chamber and a metallic one has high dielectric constant which generates reflective electromagnetic waves to influence test parameters in the chamber. The newly developed pneumatic actuator is made from low dielectric constant plastics with less reflective of electromagnetic. A turbine-type air motor is used to develop the pneumatic actuator and a employ Prony tester is used to run the brake horsepower test for the performance test of pneumatic actuator. Test results indicate that the pneumatic actuator in the minimal starting flow is 17 l/min, and it generates a brake horsepower of 48 mW; in the maximum flow is 26 l/min, it generates a brake horsepower of 108 mW. Therefore, it works with a torque between 0.24 N-m and 0.55 N-m, and such a torque will be sufficient to drive the target button.
Fully wireless pressure sensor based on endoscopy images
NASA Astrophysics Data System (ADS)
Maeda, Yusaku; Mori, Hirohito; Nakagawa, Tomoaki; Takao, Hidekuni
2018-04-01
In this paper, the result of developing a fully wireless pressure sensor based on endoscopy images for an endoscopic surgery is reported for the first time. The sensor device has structural color with a nm-scale narrow gap, and the gap is changed by air pressure. The structural color of the sensor is acquired from camera images. Pressure detection can be realized with existing endoscope configurations only. The inner air pressure of the human body should be measured under flexible-endoscope operation using the sensor. Air pressure monitoring, has two important purposes. The first is to quantitatively measure tumor size under a constant air pressure for treatment selection. The second purpose is to prevent the endangerment of a patient due to over transmission of air. The developed sensor was evaluated, and the detection principle based on only endoscopy images has been successfully demonstrated.
Chiang, Mao-Hsiung
2010-01-01
This study aims to develop a X-Y dual-axial intelligent servo pneumatic-piezoelectric hybrid actuator for position control with high response, large stroke (250 mm, 200 mm) and nanometer accuracy (20 nm). In each axis, the rodless pneumatic actuator serves to position in coarse stroke and the piezoelectric actuator compensates in fine stroke. Thus, the overall control systems of the single axis become a dual-input single-output (DISO) system. Although the rodless pneumatic actuator has relatively larger friction force, it has the advantage of mechanism for multi-axial development. Thus, the X-Y dual-axial positioning system is developed based on the servo pneumatic-piezoelectric hybrid actuator. In addition, the decoupling self-organizing fuzzy sliding mode control is developed as the intelligent control strategies. Finally, the proposed novel intelligent X-Y dual-axial servo pneumatic-piezoelectric hybrid actuators are implemented and verified experimentally.
Chiang, Mao-Hsiung
2010-01-01
This study aims to develop a X-Y dual-axial intelligent servo pneumatic-piezoelectric hybrid actuator for position control with high response, large stroke (250 mm, 200 mm) and nanometer accuracy (20 nm). In each axis, the rodless pneumatic actuator serves to position in coarse stroke and the piezoelectric actuator compensates in fine stroke. Thus, the overall control systems of the single axis become a dual-input single-output (DISO) system. Although the rodless pneumatic actuator has relatively larger friction force, it has the advantage of mechanism for multi-axial development. Thus, the X-Y dual-axial positioning system is developed based on the servo pneumatic-piezoelectric hybrid actuator. In addition, the decoupling self-organizing fuzzy sliding mode control is developed as the intelligent control strategies. Finally, the proposed novel intelligent X-Y dual-axial servo pneumatic-piezoelectric hybrid actuators are implemented and verified experimentally. PMID:22319266
Variable camber wing based on pneumatic artificial muscles
NASA Astrophysics Data System (ADS)
Yin, Weilong; Liu, Libo; Chen, Yijin; Leng, Jinsong
2009-07-01
As a novel bionic actuator, pneumatic artificial muscle has high power to weight ratio. In this paper, a variable camber wing with the pneumatic artificial muscle is developed. Firstly, the experimental setup to measure the static output force of pneumatic artificial muscle is designed. The relationship between the static output force and the air pressure is investigated. Experimental result shows the static output force of pneumatic artificial muscle decreases nonlinearly with increasing contraction ratio. Secondly, the finite element model of the variable camber wing is developed. Numerical results show that the tip displacement of the trailing-edge increases linearly with increasing external load and limited with the maximum static output force of pneumatic artificial muscles. Finally, the variable camber wing model is manufactured to validate the variable camber concept. Experimental result shows that the wing camber increases with increasing air pressure and that it compare very well with the FEM result.
NASA Astrophysics Data System (ADS)
Burk, Laurel M.; Lee, Yueh Z.; Wait, J. Matthew; Lu, Jianping; Zhou, Otto Z.
2012-09-01
A cone beam micro-CT has previously been utilized along with a pressure-tracking respiration sensor to acquire prospectively gated images of both wild-type mice and various adult murine disease models. While the pressure applied to the abdomen of the subject by this sensor is small and is generally without physiological effect, certain disease models of interest, as well as very young animals, are prone to atelectasis with added pressure, or they generate too weak a respiration signal with this method to achieve optimal prospective gating. In this work we present a new fibre-optic displacement sensor which monitors respiratory motion of a subject without requiring physical contact. The sensor outputs an analogue signal which can be used for prospective respiration gating in micro-CT imaging. The device was characterized and compared against a pneumatic air chamber pressure sensor for the imaging of adult wild-type mice. The resulting images were found to be of similar quality with respect to physiological motion blur; the quality of the respiration signal trace obtained using the non-contact sensor was comparable to that of the pressure sensor and was superior for gating purposes due to its better signal-to-noise ratio. The non-contact sensor was then used to acquire in-vivo micro-CT images of a murine model for congenital diaphragmatic hernia and of 11-day-old mouse pups. In both cases, quality CT images were successfully acquired using this new respiration sensor. Despite the presence of beam hardening artefacts arising from the presence of a fibre-optic cable in the imaging field, we believe this new technique for respiration monitoring and gating presents an opportunity for in-vivo imaging of disease models which were previously considered too delicate for established animal handling methods.
NASA Technical Reports Server (NTRS)
2008-01-01
Topics covered include: Torque Sensor Based on Tunnel-Diode Oscillator; Shaft-Angle Sensor Based on Tunnel-Diode Oscillator; Ground Facility for Vicarious Calibration of Skyborne Sensors; Optical Pressure-Temperature Sensor for a Combustion Chamber; Impact-Locator Sensor Panels; Low-Loss Waveguides for Terahertz Frequencies; MEMS/ECD Method for Making Bi(2-x)Sb(x)Te3 Thermoelectric Devices; Low-Temperature Supercapacitors; Making a Back-Illuminated Imager with Back-Side Contact and Alignment Markers; Compact, Single-Stage MMIC InP HEMT Amplifier; Nb(x)Ti(1-x)N Superconducting-Nanowire Single-Photon Detectors; Improved Sand-Compaction Method for Lost-Foam Metal Casting; Improved Probe for Evaluating Compaction of Mold Sand; Polymer-Based Composite Catholytes for Li Thin-Film Cells; Using ALD To Bond CNTs to Substrates and Matrices; Alternating-Composition Layered Ceramic Barrier Coatings; Variable-Structure Control of a Model Glider Airplane; Axial Halbach Magnetic Bearings; Compact, Non-Pneumatic Rock-Powder Samplers; Biochips Containing Arrays of Carbon-Nanotube Electrodes; Nb(x)Ti(1-x)N Superconducting-Nanowire Single-Photon Detectors; Neon as a Buffer Gas for a Mercury-Ion Clock; Miniature Incandescent Lamps as Fiber-Optic Light Sources; Bidirectional Pressure-Regulator System; and Prism Window for Optical Alignment. Single-Grid-Pair Fourier Telescope for Imaging in Hard-X Rays and gamma Rays Range-Gated Metrology with Compact Optical Head Lossless, Multi-Spectral Data Compressor for Improved Compression for Pushbroom-Typetruments.
Pneumatic wrench retains or discharges nuts or bolts as desired
NASA Technical Reports Server (NTRS)
Bouille, J. R.
1966-01-01
Pneumatic wrench grips, screws or unscrews, and discharges a nut or bolt as desired. The device consists of a standard pneumatic wrench modified with a special hex bolt head socket assembly and a diaphragm air cylinder.
Pneumatic conveyance apparatus and process
Heckendorn, Frank M.; Matzolf, Athneal D.; Hera, Kevin R.
2010-05-04
A pneumatic nozzle capable of removing dry solid debris, liquids, and mixtures of solid and liquid waste is provided. The pneumatic nozzle uses a pressurized gas stream to push materials through the nozzle. The force of a pressurized gas stream provides a partial vacuum to allow material to be introduced into an opening of a nozzle via a slight suction force. Thereafter, individual particles and materials introduced into the pneumatic nozzle are pushed by a stream of pressurized gas through the nozzle.
Does the Degree of the Mastoid Pneumatization Affect the Side of Bell Palsy?
Güneş, Selçuk; Çelik, Mustafa; Çolak, Ceylan; Olgun, Burak
2018-02-26
The aim is to investigate the impact of degree of mastoid pneumatization on the affected side of Bell palsy (BP). Retrospective study in tertiary academic hospital. In total, 52 patients who were diagnosed with as BP were included in the study. Each patient was staged using House-Brackmann (HB) staging system. All patients underwent temporal bone computed tomography imaging. House-Brackmann scores, side of the BP, and mastoid pneumatization of all of patients were evaluated in the present study. Regarding the degree of the mastoid pneumatization, there were no significant differences between the affected side and the unaffected side (P = 0.439). The degree of the mastoid pneumatization of the affected side and the unaffected side did not differ between males and females (P = 0.918 for the affected side, P = 0.765 for the unaffected side, respectively). A negative correlation between the age and mastoid pneumatization of each side was found (P = 0.001, P = 0.025, respectively). There was no significant correlation between HB score and the degree of the mastoid pneumatization of each side (P = 0.789, P = 0.703). As a conclusion, the degree of the mastoid pneumatization is not one of the risk factors for BP. Further randomized studies with larger numbers of patients are needed to confirm these findings.
Cranial base morphology and temporal bone pneumatization in Asian Homo erectus.
Balzeau, Antoine; Grimaud-Hervé, Dominique
2006-10-01
The external morphological features of the temporal bone are used frequently to determine taxonomic affinities of fossils of the genus Homo. Temporal bone pneumatization has been widely studied in great apes and in early hominids. However, this feature is rarely examined in the later hominids, particularly in Asian Homo erectus. We provide a comparative morphological and quantitative analysis of Asian Homo erectus from the sites of Ngandong, Sambungmacan, and Zhoukoudian, and of Neandertals and anatomically modern Homo sapiens in order to discuss causes and modalities of temporal bone pneumatization during hominid evolution. The evolution of temporal bone pneumatization in the genus Homo is more complex than previously described. Indeed, the Zhoukoudian fossils have a unique pattern of temporal bone pneumatization, whereas Ngandong and Sambungmacan fossils, as well as the Neandertals, more closely resemble the modern human pattern. Moreover, these Chinese fossils are characterized by a wide midvault and a relatively narrow occipital bone. Our results support the point of view that cell development does not play an active role in determining cranial base morphology. Instead, pneumatization is related to available space and to temporal bone morphology, and its development is related to correlated morphology and the relative disposition of the bones and cerebral lobes. Because variation in pneumatization is extensive within the same species, the phyletic implications of pneumatization are limited in the taxa considered here.
NASA Astrophysics Data System (ADS)
Burhan, I.; Azman, A. A.; Othman, R.
2016-10-01
An electro pneumatic trainer embedded with programmable integrated circuit (PIC) microcontroller and Visual Basic (VB) platform is fabricated as a supporting tool to existing teaching and learning process, and to achieve the objectives and learning outcomes towards enhancing the student's knowledge and hands-on skill, especially in electro pneumatic devices. The existing learning process for electro pneumatic courses conducted in the classroom does not emphasize on simulation and complex practical aspects. VB is used as the platform for graphical user interface (GUI) while PIC as the interface circuit between the GUI and hardware of electro pneumatic apparatus. Fabrication of electro pneumatic trainer interfacing between PIC and VB has been designed and improved by involving multiple types of electro pneumatic apparatus such as linear drive, air motor, semi rotary motor, double acting cylinder and single acting cylinder. Newly fabricated electro pneumatic trainer microcontroller interface can be programmed and re-programmed for numerous combination of tasks. Based on the survey to 175 student participants, 97% of the respondents agreed that the newly fabricated trainer is user friendly, safe and attractive, and 96.8% of the respondents strongly agreed that there is improvement in knowledge development and also hands-on skill in their learning process. Furthermore, the Lab Practical Evaluation record has indicated that the respondents have improved their academic performance (hands-on skills) by an average of 23.5%.
21 CFR 870.2780 - Hydraulic, pneumatic, or photoelectric plethysmographs.
Code of Federal Regulations, 2012 CFR
2012-04-01
... HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Monitoring Devices..., pneumatic, or photoelectric plethysmograph is a device used to estimate blood flow in a region of the body using hydraulic, pneumatic, or photoelectric measurement techniques. (b) Classification. Class II...
21 CFR 870.2780 - Hydraulic, pneumatic, or photoelectric plethysmographs.
Code of Federal Regulations, 2014 CFR
2014-04-01
... HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Monitoring Devices..., pneumatic, or photoelectric plethysmograph is a device used to estimate blood flow in a region of the body using hydraulic, pneumatic, or photoelectric measurement techniques. (b) Classification. Class II...
21 CFR 870.2780 - Hydraulic, pneumatic, or photoelectric plethysmographs.
Code of Federal Regulations, 2013 CFR
2013-04-01
... HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Monitoring Devices..., pneumatic, or photoelectric plethysmograph is a device used to estimate blood flow in a region of the body using hydraulic, pneumatic, or photoelectric measurement techniques. (b) Classification. Class II...
A Compact Microwave Microfluidic Sensor Using a Re-Entrant Cavity.
Hamzah, Hayder; Abduljabar, Ali; Lees, Jonathan; Porch, Adrian
2018-03-19
A miniaturized 2.4 GHz re-entrant cavity has been designed, manufactured and tested as a sensor for microfluidic compositional analysis. It has been fully evaluated experimentally with water and common solvents, namely methanol, ethanol, and chloroform, with excellent agreement with the expected behaviour predicted by the Debye model. The sensor's performance has also been assessed for analysis of segmented flow using water and oil. The samples' interaction with the electric field in the gap region has been maximized by aligning the sample tube parallel to the electric field in this region, and the small width of the gap (typically 1 mm) result in a highly localised complex permittivity measurement. The re-entrant cavity has simple mechanical geometry, small size, high quality factor, and due to the high concentration of electric field in the gap region, a very small mode volume. These factors combine to result in a highly sensitive, compact sensor for both pure liquids and liquid mixtures in capillary or microfluidic environments.
Apostolaki, Naomi E.; Rayfield, Emily J.; Barrett, Paul M.
2015-01-01
Postcranial skeletal pneumaticity (PSP) is a condition most notably found in birds, but that is also present in other saurischian dinosaurs and pterosaurs. In birds, skeletal pneumatization occurs where bones are penetrated by pneumatic diverticula, membranous extensions that originate from air sacs that serve in the ventilation of the lung. Key questions that remain to be addressed include further characterizing (1) the skeletal features that can be used to infer the presence/absence and extent of PSP in birds and non-avian dinosaurs, and (2) the association between vertebral laminae and specific components of the avian respiratory system. Previous work has used vertebral features such as pneumatic foramina, fossae, and laminae to identify/infer the presence of air sacs and diverticula, and to discuss the range of possible functions of such features. Here, we tabulate pneumatic features in the vertebral column of 11 avian taxa, including the flightless ratites and selected members of semi-volant and semi-aquatic Neornithes. We investigate the associations of these osteological features with each other and, in the case of Struthio camelus, with the specific presence of pneumatic diverticula. We find that the mere presence of vertebral laminae does not indicate the presence of skeletal pneumaticity, since laminae are not always associated with pneumatic foramina or fossae. Nevertheless, laminae are more strongly developed when adjacent to foramina or fossae. In addition, membranous air sac extensions and adjacent musculature share the same attachment points on the vertebrae, rendering the use of such features for reconstructing respiratory soft tissue features ambiguous. Finally, pneumatic diverticula attach to the margins of laminae, foramina, and/or fossae prior to their intraosseous course. Similarities in PSP distribution among the examined taxa are concordant with their phylogenetic interrelationships. The possible functions of PSP are discussed in brief, based upon variation in the extent of PSP between taxa with differing ecologies. PMID:26649745
Legin, G A; Bondarchuk, A O; Perebetjuk, A N
2015-01-01
The objective of the present study was to compare the injurious action of three types of the bullets for the pneumatic weapons shot from different distances using the Gamo pump air pistol and the BAM B22-1 pneumatic rifle. The following four kinds of the bullets were tested: "the fireball", "Luman cap 0.3", "Luman Field Target 0.68" and "DIABOLO". It was experimentally shown that the injurious action of the bullets fired from the same distance from the pneumatic weapons depends on the type of both the bullet and the weapon, as well as the properties of the target material. Specifically, the action of bullets fired from the piston pneumatic rifle remained stable whereas that of the bullets shot from the gas-balloon air pistol decreased as the gas was exhausted. The studies by the contact-diffusion method have demonstrated that the entrance bullet holes created by the shots from pneumatic weapons are surrounded by dispersed metal particles which makes it possible to estimate the shooting distance. Moreover, the bullets fired from the pneumatic weapons leave the muzzle face imprint on certain target materials.
A method of transmissibility design for dual-chamber pneumatic vibration isolator
NASA Astrophysics Data System (ADS)
Lee, Jeung-Hoon; Kim, Kwang-Joon
2009-06-01
Dual-chamber pneumatic vibration isolators have a wide range of applications for vibration isolation of vibration-sensitive equipment. Recent advances in precision machine tools and instruments such as medical devices and those related to nano-technology require better isolation performance, which can be efficiently achieved by precise modeling- and design- of the isolation system. This paper discusses an efficient transmissibility design method of a pneumatic vibration isolator wherein a complex stiffness model of a dual-chamber pneumatic spring developed in our previous study is employed. Three design parameters, the volume ratio between the two pneumatic chambers, the geometry of the capillary tube connecting the two pneumatic chambers, and, finally, the stiffness of the diaphragm employed for prevention of air leakage, were found to be important factors in transmissibility design. Based on a design technique that maximizes damping of the dual-chamber pneumatic spring, trade-offs among the resonance frequency of transmissibility, peak transmissibility, and transmissibility in high frequency range were found, which were not ever stated in previous researches. Furthermore, this paper discusses the negative role of the diaphragm in transmissibility design. The design method proposed in this paper is illustrated through experimental measurements.
49 CFR 574.6 - Identification mark.
Code of Federal Regulations, 2010 CFR
2010-10-01
... ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) TIRE IDENTIFICATION AND RECORDKEEPING § 574.6... retreaded pneumatic tires, non-pneumatic tires or non-pneumatic tire assemblies shall apply in writing to... Street SW., Washington, DC 20590, identify itself as a tire manufacturer or retreader and furnish the...
Vibration and recoil control of pneumatic hammers. [by air flow pressure regulation
NASA Technical Reports Server (NTRS)
Constantinescu, I. N.; Darabont, A. V.
1974-01-01
Vibration sources are described for pneumatic hammers used in the mining industry (pick hammers), in boiler shops (riveting hammers), etc., bringing to light the fact that the principal vibration source is the variation in air pressure inside the cylinder. The present state of the art of vibration control of pneumatic hammers as it is practiced abroad, and the solutions adopted for this purpose, are discussed. A new type of pneumatic hammer with a low noise and vibration level is presented.
Pneumatic Compression, But Not Exercise, Can Avoid Intradialytic Hypotension: A Randomized Trial.
Álvares, Valeria R C; Ramos, Camila D; Pereira, Benedito J; Pinto, Ana Lucia; Moysés, Rosa M A; Gualano, Bruno; Elias, Rosilene M
2017-01-01
Conventional hemodialysis (HD) is associated with dialysis-induced hypotension (DIH) and ineffective phosphate removal. As the main source of extracellular fluid removed during HD are the legs, we sought to reduce DIH and increase phosphate removal by using cycling and pneumatic compression, which would potentially provide higher venous return, preserving central blood flow and also offering more phosphate to the dialyzer. We evaluated 21 patients in a randomized crossover fashion in which each patient underwent 3 different HD: control; cycling exercise during the first 60 min; and pneumatic compression during the first 60 min. Data obtained included bioelectrical impedance, hourly blood pressure measurement, biochemical parameters, and direct quantification of phosphate through the dialysate. DIH was defined as a drop in mean arterial pressure (MAP) ≥20 mm Hg. There was no difference in the ultrafiltration rate (p = 0.628), delta weight (p = 0.415), delta of total, intra and extracellular body water among the control, cycling, and pneumatic compression (p = 0.209, p = 0.348, and p = 0.467 respectively). Delta MAP was less changed by pneumatic compression when compared to control, cycling, and pneumatic compression respectively (-4.7 [-17.2, 8.2], -4.7 [-20.5, -0.2], and -2.3 [-8.1, 9.0] mm Hg; p = 0.021). DIH occurred in 43, 38, and 24% of patients in control, cycling, and pneumatic compression respectively (p = 0.014). Phosphate removal did not increase in any intervention (p = 0.486). Higher phosphate removal was dependent on ultrafiltration, pre dialysis serum phosphate, and higher parathyroid hormone. Pneumatic compression during the first hour of dialysis was associated with less DIH, albeit there was no effect on fluid parameters. Neither exercise nor pneumatic compression increased phosphate removal. © 2017 S. Karger AG, Basel.
Basic Pneumatics. Instructor's Guide.
ERIC Educational Resources Information Center
Fessehaye, Michael
This instructor's guide is designed for use by industrial vocational teachers in teaching a course on basic pneumatics. Covered in the individual units are the following topics: an introduction to pneumatics (including the operation of a service station hoist); fundamentals and physical laws; air compressors (positive displacement compressors;…
Hemolysis associated with pneumatic tube system transport for blood samples
Kara, Hasan; Bayir, Aysegul; Ak, Ahmet; Degirmenci, Selim; Akinci, Murat; Agacayak, Ahmet; Marcil, Emine; Azap, Melih
2014-01-01
Objective: The frequency of hemolysis of blood samples may be increased by transport in a pneumatic tube system. The purpose of this study was to evaluate the effect of pneumatic tube system transport on hemolysis of blood samples. Methods: Blood samples were transported from the emergency department to the hospital laboratory manually by hospital staff (49 patients) or with a pneumatic tube system (53 patients). The hemolysis index and serum chemistry studies were performed on the blood samples and compared between the different methods of transport. Results: The blood samples that were transported by the pneumatic tube system had a greater frequency of hemolysis and greater mean serum potassium and median creatinine, aspartate aminotransferase, and lactate dehydrogenase levels than samples transported manually. Conclusion: Blood samples transported from the emergency department to the hospital laboratory by a pneumatic tube system may have a greater frequency of hemolysis than samples transported manually. This may necessitate repeat phlebotomy and cause a delay in completing the laboratory analysis. PMID:24639830
21 CFR 882.4370 - Pneumatic cranial drill motor.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Pneumatic cranial drill motor. 882.4370 Section 882.4370 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES NEUROLOGICAL DEVICES Neurological Surgical Devices § 882.4370 Pneumatic cranial...
21 CFR 882.4370 - Pneumatic cranial drill motor.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Pneumatic cranial drill motor. 882.4370 Section 882.4370 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES NEUROLOGICAL DEVICES Neurological Surgical Devices § 882.4370 Pneumatic cranial...
The study of fix composite panel and steel plates on testing stand
NASA Astrophysics Data System (ADS)
Wróbel, A.; Płaczek, M.; Wachna, M.
2016-08-01
In this paper the practical possibilities of strength verification analysis of composite materials used in the manufacture of selected components of railway wagons are presented. Real laboratory stand for measurements in a scale controlled by PLC controller were made. The study of different types of connections of composite materials with sheet metal is presented. In one of the chapter of this paper principles construction of testing stand with pneumatic cylinder were presented. Mainly checking of displacements and stresses generated on the sheet as a result of pneumatic actuators load for composite boards was carried out. The use of the controller with operating panel allows to easy programming testing cycle. The user can define the force generated by the actuator by change of air pressure in cylinder. Additionally the location of acting cylinders and their jump can be changed by operator. The examination of the volume displacements was done by displacement sensor, and the tensile strain gauge. All parameters are written in CatmanEasy - data acquisition software. This article presents the study of stresses and displacements in the composite plates joined with sheet metal, in summary of this article, the authors compare the obtained results with the computer simulation results in the article: "Simulation of stresses in an innovative combination of composite with sheet".
NASA Astrophysics Data System (ADS)
Hittle, D. C.; Johnson, D. L.
1985-01-01
This report is one of a series on the development of heating, ventilating, and air-conditioning (HVAC) control systems that are simple, efficient, reliable, maintainable, and well-documented. This report identifies major problems associated with three currently used HVAC control systems. It also describes the development of a retrofit control system applicable to military buildings that will allow easy identification of component failures, facilitate repair, and minimize system failures. Evaluation of currently used controls showed that pneumatic temperature control equipment requires a very clean source of supply air and is also not very accurate. Pneumatic, rather than electronic, actuators should be used because they are cheaper and require less maintenance. Thermistor temperature detectors should not be used for HVAC applications because they require frequent calibration. It was found that enthalpy economy cycles cannot be used for control because the humidity sensors required for their use are prone to rapid drift, inaccurate, and hard to calibrate in the field. Performance of control systems greatly affects HVAC operating costs. Significant savings can be achieved if proportional-plus-integral control schemes are used. Use of the retrofit prototype control panel developed in this study on variable-air-volume systems should provide significant energy cost savings, improve comfort and reliability, and reduce maintenance costs.
Connecting apparatus for limited rotary of rectilinear motion (II)
Hardin, Jr., Roy T.; Kurinko, Carl D.
1981-01-01
Apparatus for providing connection between two members having relative movement in a horizontal plane in a rotary or linear fashion. The apparatus includes a set of vertical surfaces affixed to each of the members, laterally aligned across a selected vertical gap. A number of cables or hoses, for electrical, hydraulic, or pneumatic connection are arranged between consecutive surfaces in a C-shaped traveling loop, connected through their end portions to the two respective members, so that through a sliding motion portions of the cable are transferred from between one set of surfaces to the other aligned set, across the gap, upon relative motion of the members. A number of flexible devices are affixed to the upper set of surfaces for supporting the upper portion of each looped cable. The apparatus is particularly adaptable to an area having limited lateral clearances and requiring signal level separation between electrical cables, such as found in the rotating plugs and associated equipment of the reactor vessel head of a nuclear reactor.
Low Cost Sensors-Current Capabilities and Gaps
1. Present the findings from the a recent technology review of gas and particulate phase sensors 2. Focus on the lower-cost sensors 3. Discuss current capabilities, estimated range of measurement, selectivity, deployment platforms, response time, and expected range of acceptabl...
40 CFR 60.253 - Standards for pneumatic coal-cleaning equipment.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 7 2013-07-01 2013-07-01 false Standards for pneumatic coal-cleaning... PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Coal Preparation and Processing Plants § 60.253 Standards for pneumatic coal-cleaning equipment. (a) On and after...
40 CFR 60.253 - Standards for pneumatic coal-cleaning equipment.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 6 2011-07-01 2011-07-01 false Standards for pneumatic coal-cleaning... PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Coal Preparation and Processing Plants § 60.253 Standards for pneumatic coal-cleaning equipment. (a) On and after...
40 CFR 60.253 - Standards for pneumatic coal-cleaning equipment.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 7 2012-07-01 2012-07-01 false Standards for pneumatic coal-cleaning... PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Coal Preparation and Processing Plants § 60.253 Standards for pneumatic coal-cleaning equipment. (a) On and after...
40 CFR 60.253 - Standards for pneumatic coal-cleaning equipment.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 6 2010-07-01 2010-07-01 false Standards for pneumatic coal-cleaning... PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Coal Preparation and Processing Plants § 60.253 Standards for pneumatic coal-cleaning equipment. (a) On and after...
40 CFR 60.253 - Standards for pneumatic coal-cleaning equipment.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 7 2014-07-01 2014-07-01 false Standards for pneumatic coal-cleaning... PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Coal Preparation and Processing Plants § 60.253 Standards for pneumatic coal-cleaning equipment. (a) On and after...
DOT National Transportation Integrated Search
1978-03-01
This report deals with the selection of a test site, the design of a test installation, equipment selection, the installation and start-up of a pneumatic pipeline system for the transportation of tunnel muck. A review of prior pneumatic applications ...
Web-Based Learning and Instruction Support System for Pneumatics
ERIC Educational Resources Information Center
Yen, Chiaming; Li, Wu-Jeng
2003-01-01
This research presents a Web-based learning and instructional system for Pneumatics. The system includes course material, remote data acquisition modules, and a pneumatic laboratory set. The course material is in the HTML format accompanied with text, still and animated images, simulation programs, and computer aided design tools. The data…
Hardee, Harry C.
1991-01-01
A rotary pneumatic valve which is thrust balanced and the pneumatic pressure developed produces only radial loads on the valve cylinder producing negligible resistance and thus minimal torque on the bearings of the valve. The valve is multiplexed such that at least two complete switching cycles occur for each revolution of the cylinder spindle.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Miller, Benjamin, E-mail: BenjaminMiller@nyc.rr.com; Spertus, Juliette, E-mail: Juliette.Spertus@gmail.com; Kamga, Camille, E-mail: CKamga@UTRC2.org
Highlights: • Pneumatic and truck collection were compared in three New York City locations. • Relative costs, energy use, and greenhouse gas emissions varied significantly. • Variations were due to location-specific factors (e.g., route density, truck type). • Under appropriate conditions, pneumatic collection reduces TMT, BTU, and GHG. • Pneumatic capex may be offset by operating savings and externality benefits. - Abstract: Truck-based collection of municipal solid waste imposes significant negative externalities on cities and constrains the efficiency of separate collection of recyclables and organics and of unit-price-based waste-reduction systems. In recent decades, hundreds of municipal-scale pneumatic collection systems havemore » been installed in Europe and Asia. Relatively few prior studies have compared the economic or environmental impacts of these systems to those of truck collection. A critical factor to consider when making this comparison is the extent to which the findings reflect the specific geographic, demographic, and operational characteristics of the systems considered. This paper is based on three case studies that consider the specific characteristics of three locations, comparing pneumatic systems with conventional collection on the basis of actual waste tonnages, composition, sources, collection routes, truck trips, and facility locations. In one case, alternative upgrades to an existing pneumatic system are compared to a potential truck-collection operation. In the other cases, existing truck operations are compared to proposed pneumatic systems which, to reduce capital costs, would be installed without new trenching or tunneling through the use of existing linear infrastructure. For the two proposed retrofit pneumatic systems, up to 48,000 truck kilometers travelled would be avoided and energy use would be reduced by up to 60% at an incremental cost of up to $400,000 USD per year over the total operating-plus-capital cost of conventional collection. In the location where a greenfield pneumatic system is already in operation, truck collection would be both less expensive and more energy-efficient than pneumatic collection. The results demonstrate that local geographic, demographic, and operational conditions play a decisive role in determining whether pneumatic collection will reduce energy requirements, produce more or fewer greenhouse gas emissions, and cost more or less over the long-term. These findings point to the local factors that will determine the relative economic and environmental costs and benefits in specific situations.« less
NASA Astrophysics Data System (ADS)
Yoon, Young Zoon; Kim, Hyochul; Park, Yeonsang; Kim, Jineun; Lee, Min Kyung; Kim, Un Jeong; Roh, Young-Geun; Hwang, Sung Woo
2016-09-01
Wearable devices often employ optical sensors, such as photoplethysmography sensors, for detecting heart rates or other biochemical factors. Pulse waveforms, rather than simply detecting heartbeats, can clarify arterial conditions. However, most optical sensor designs require close skin contact to reduce power consumption while obtaining good quality signals without distortion. We have designed a detection-gap-independent optical sensor array using divergence-beam-controlled slit lasers and distributed photodiodes in a pulse-detection device wearable over the wrist's radial artery. It achieves high biosignal quality and low power consumption. The top surface of a vertical-cavity surface-emitting laser of 850 nm wavelength was covered by Au film with an open slit of width between 500 nm and 1500 nm, which generated laser emissions across a large divergence angle along an axis orthogonal to the slit direction. The sensing coverage of the slit laser diode (LD) marks a 50% improvement over nonslit LD sensor coverage. The slit LD sensor consumes 100% more input power than the nonslit LD sensor to obtain similar optical output power. The slit laser sensor showed intermediate performance between LD and light-emitting diode sensors. Thus, designing sensors with multiple-slit LD arrays can provide useful and convenient ways for incorporating optical sensors in wrist-wearable devices.
Pneumatic-type surgical robot end-effector for laparoscopic surgical-operation-by-wire.
Lee, Chiwon; Park, Woo Jung; Kim, Myungjoon; Noh, Seungwoo; Yoon, Chiyul; Lee, Choonghee; Kim, Youdan; Kim, Hyeon Hoe; Kim, Hee Chan; Kim, Sungwan
2014-09-05
Although minimally invasive surgery (MIS) affords several advantages compared to conventional open surgery, robotic MIS systems still have many limitations. One of the limitations is the non-uniform gripping force due to mechanical strings of the existing systems. To overcome this limitation, a surgical instrument with a pneumatic gripping system consisting of a compressor, catheter balloon, micro motor, and other parts is developed. This study aims to implement a surgical instrument with a pneumatic gripping system and pitching/yawing joints using micro motors and without mechanical strings based on the surgical-operation-by-wire (SOBW) concept. A 6-axis external arm for increasing degrees of freedom (DOFs) is integrated with the surgical instrument using LabVIEW® for laparoscopic procedures. The gripping force is measured over a wide range of pressures and compared with the simulated ideal step function. Furthermore, a kinematic analysis is conducted. To validate and evaluate the system's clinical applicability, a simple peg task experiment and workspace identification experiment are performed with five novice volunteers using the fundamentals of laparoscopic surgery (FLS) board kit. The master interface of the proposed system employs the hands-on-throttle-and-stick (HOTAS) controller used in aerospace engineering. To develop an improved HOTAS (iHOTAS) controller, 6-axis force/torque sensor was integrated in the special housing. The mean gripping force (after 1,000 repetitions) at a pressure of 0.3 MPa was measured to be 5.8 N. The reaction time was found to be 0.4 s, which is almost real-time. All novice volunteers could complete the simple peg task within a mean time of 176 s, and none of them exceeded the 300 s cut-off time. The system's workspace was calculated to be 11,157.0 cm3. The proposed pneumatic gripping system provides a force consistent with that of other robotic MIS systems. It provides near real-time control. It is more durable than the existing other surgical robot systems. Its workspace is sufficient for clinical surgery. Therefore, the proposed system is expected to be widely used for laparoscopic robotic surgery. This research using iHOTAS will be applied to the tactile force feedback system for surgeon's safe operation.
NASA Astrophysics Data System (ADS)
Wang, Chao; Zhang, Jingyu; Gao, Wenbin; Ding, Hongbing; Wu, Weiping
2015-11-01
The gas-solid two-phase flow has been widely applied in the power, chemical and metallurgical industries. It is of great significance in the research of gas-solid two-phase flow to measure particle velocity at different locations in the pipeline. Thus, an electrostatic sensor array comprising eight arc-shaped electrodes was designed. The relationship between the cross-correlation (CC) velocity and the distribution of particle velocity, charge density and electrode spatial sensitivity was analysed. Then the CC sensitivity and its calculation method were proposed. According to the distribution of CC sensitivity, it was found that, between different electrode pairs, it had different focus areas. The CC focus method was proposed for particle velocity measurement at different locations and validated by a belt-style electrostatic induction experiment facility. Finally, the particle velocities at different locations with different flow conditions were measured to research the particle velocity distribution in a dilute horizontal pneumatic conveying pipeline.
Trace explosives sensor testbed (TESTbed)
NASA Astrophysics Data System (ADS)
Collins, Greg E.; Malito, Michael P.; Tamanaha, Cy R.; Hammond, Mark H.; Giordano, Braden C.; Lubrano, Adam L.; Field, Christopher R.; Rogers, Duane A.; Jeffries, Russell A.; Colton, Richard J.; Rose-Pehrsson, Susan L.
2017-03-01
A novel vapor delivery testbed, referred to as the Trace Explosives Sensor Testbed, or TESTbed, is demonstrated that is amenable to both high- and low-volatility explosives vapors including nitromethane, nitroglycerine, ethylene glycol dinitrate, triacetone triperoxide, 2,4,6-trinitrotoluene, pentaerythritol tetranitrate, and hexahydro-1,3,5-trinitro-1,3,5-triazine. The TESTbed incorporates a six-port dual-line manifold system allowing for rapid actuation between a dedicated clean air source and a trace explosives vapor source. Explosives and explosives-related vapors can be sourced through a number of means including gas cylinders, permeation tube ovens, dynamic headspace chambers, and a Pneumatically Modulated Liquid Delivery System coupled to a perfluoroalkoxy total-consumption microflow nebulizer. Key features of the TESTbed include continuous and pulseless control of trace vapor concentrations with wide dynamic range of concentration generation, six sampling ports with reproducible vapor profile outputs, limited low-volatility explosives adsorption to the manifold surface, temperature and humidity control of the vapor stream, and a graphical user interface for system operation and testing protocol implementation.
Sphenoid sinus types, dimensions and relationship with surrounding structures.
Štoković, Nikola; Trkulja, Vladimir; Dumić-Čule, Ivo; Čuković-Bagić, Ivana; Lauc, Tomislav; Vukičević, Slobodan; Grgurević, Lovorka
2016-01-01
The human sphenoid sinus is an extremely variable cavity and an important landmark in hypophyseal surgery. The aim of this study was to investigate the relationship between the sphenoid sinus type, size, extent of pneumatization and occurrence of protrusions of the adjacent neurovascular structures. A total of 51 randomly selected skulls (≥20 years of age, 33 male; 102 sinuses) were analyzed using cone beam computed tomography to estimate pneumatization extension beyond the body of the sphenoid (planum sphenoidale, pterygoid process, greater wings, clivus, dorsum sellae) and protrusions of the maxillary, mandibular, optic or pterygoid nerve or the internal carotid artery. Difference in pneumatization type between the left and the right-sided sinus was observed in 45% of the skulls. Conchal pneumatization was registered in 2%, presellar in 24%, sellar in 41% and postsellar in 33% of total sinuses. Presellar sinuses frequently pneumatized planum sphenoidale and sporadically other structures, and were characterized by sporadic optic nerve protrusions. Sellar and particularly postsellar sinuses were characterized by simultaneous pneumatization extensions and neurovascular protrusions. In the case of postsellar-type sinuses, the probability of these multiple interactions was not affected by their actual size, while it increased with the increasing sinus dimensions in the case of sellar-type sinuses. A more detailed analysis indicated that increasing sinus height, length or width increased the probability of interactions and pneumatization of particular surrounding structures. Data suggest that the sphenoid sinus pneumatization type and dimensions might be used to estimate the risks of iatrogenic injury during transsphenoidal surgical procedures. Copyright © 2015 Elsevier GmbH. All rights reserved.
Xie, Xiaolong; Wu, Yang; Wang, Qi; Zhao, Yiyang; Chen, Guobin; Xiang, Bo
2017-08-08
Data of randomly controlled trials comparing the hydrostatic and pneumatic reduction for intussusception in pediatric patients as initial therapy are lacking. The aim of this study was to conduct a randomly controlled trial to compare the effectiveness and safety of the hydrostatic and pneumatic reduction techniques. All intussusception patients who visited West China Hospital of Sichuan University from January 2014 to December 2015 were enrolled in this study in which they underwent pneumatic reduction or hydrostatic reduction. Patients were randomized into ultrasound-guided hydrostatic or X-ray-guided pneumatic reduction group. The data collected includes demographic data, symptoms, signs, and investigations. The primary outcome of the study was the success rate of reduction. And the secondary outcomes of the study were the rates of intestinal perforations and recurrence. A total of 124 children with intussusception who had met the inclusion criteria were enrolled. The overall success rate of this study was 90.32%. Univariable analysis showed that the success rate of hydrostatic reduction with normal saline (96.77%) was significantly higher than that of pneumatic reduction with air (83.87%) (p=0.015). Perforation after reduction was found in only one of the pneumatic reduction group. The recurrence rate of intussusception in the hydrostatic reduction group was 4.84% compared with 3.23% of pneumatic reduction group. Our study found that ultrasound-guided hydrostatic reduction is a simple, safe and effective nonoperative treatment for pediatric patients suffering from intussusceptions, and should be firstly adopted in the treatment of qualified patients. Therapeutic study TYPE OF STUDY: Prospective study. Copyright © 2017 Elsevier Inc. All rights reserved.
Wind tunnel investigation of a high lift system with pneumatic flow control
NASA Astrophysics Data System (ADS)
Victor, Pricop Mihai; Mircea, Boscoianu; Daniel-Eugeniu, Crunteanu
2016-06-01
Next generation passenger aircrafts require more efficient high lift systems under size and mass constraints, to achieve more fuel efficiency. This can be obtained in various ways: to improve/maintain aerodynamic performance while simplifying the mechanical design of the high lift system going to a single slotted flap, to maintain complexity and improve the aerodynamics even more, etc. Laminar wings have less efficient leading edge high lift systems if any, requiring more performance from the trailing edge flap. Pulsed blowing active flow control (AFC) in the gap of single element flap is investigated for a relatively large model. A wind tunnel model, test campaign and results and conclusion are presented.
21 CFR 874.4250 - Ear, nose, and throat electric or pneumatic surgical drill.
Code of Federal Regulations, 2010 CFR
2010-04-01
... surgical drill. 874.4250 Section 874.4250 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH....4250 Ear, nose, and throat electric or pneumatic surgical drill. (a) Identification. An ear, nose, and throat electric or pneumatic surgical drill is a rotating drilling device, including the handpiece, that...
46 CFR 128.240 - Hydraulic or pneumatic power and control-materials and pressure design.
Code of Federal Regulations, 2014 CFR
2014-10-01
... Hydraulic or pneumatic power and control—materials and pressure design. (a) Each standard piping component... 46 Shipping 4 2014-10-01 2014-10-01 false Hydraulic or pneumatic power and control-materials and pressure design. 128.240 Section 128.240 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED...
46 CFR 128.240 - Hydraulic or pneumatic power and control-materials and pressure design.
Code of Federal Regulations, 2011 CFR
2011-10-01
... Hydraulic or pneumatic power and control—materials and pressure design. (a) Each standard piping component... 46 Shipping 4 2011-10-01 2011-10-01 false Hydraulic or pneumatic power and control-materials and pressure design. 128.240 Section 128.240 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED...
46 CFR 128.240 - Hydraulic or pneumatic power and control-materials and pressure design.
Code of Federal Regulations, 2012 CFR
2012-10-01
... Hydraulic or pneumatic power and control—materials and pressure design. (a) Each standard piping component... 46 Shipping 4 2012-10-01 2012-10-01 false Hydraulic or pneumatic power and control-materials and pressure design. 128.240 Section 128.240 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED...
46 CFR 128.240 - Hydraulic or pneumatic power and control-materials and pressure design.
Code of Federal Regulations, 2013 CFR
2013-10-01
... Hydraulic or pneumatic power and control—materials and pressure design. (a) Each standard piping component... 46 Shipping 4 2013-10-01 2013-10-01 false Hydraulic or pneumatic power and control-materials and pressure design. 128.240 Section 128.240 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED...
46 CFR 128.240 - Hydraulic or pneumatic power and control-materials and pressure design.
Code of Federal Regulations, 2010 CFR
2010-10-01
... Hydraulic or pneumatic power and control—materials and pressure design. (a) Each standard piping component... 46 Shipping 4 2010-10-01 2010-10-01 false Hydraulic or pneumatic power and control-materials and pressure design. 128.240 Section 128.240 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED...
Code of Federal Regulations, 2010 CFR
2010-10-01
... 49 Transportation 4 2010-10-01 2010-10-01 false Provision made for preventing operation of pneumatic brake-applying apparatus by double-heading cock; requirement. 236.565 Section 236.565... preventing operation of pneumatic brake-applying apparatus by double-heading cock; requirement. Where...
Code of Federal Regulations, 2011 CFR
2011-10-01
... 49 Transportation 4 2011-10-01 2011-10-01 false Provision made for preventing operation of pneumatic brake-applying apparatus by double-heading cock; requirement. 236.565 Section 236.565... preventing operation of pneumatic brake-applying apparatus by double-heading cock; requirement. Where...
49 CFR 571.129 - Standard No. 129; New non-pneumatic tires for passenger cars.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 49 Transportation 6 2010-10-01 2010-10-01 false Standard No. 129; New non-pneumatic tires for... VEHICLE SAFETY STANDARDS Federal Motor Vehicle Safety Standards § 571.129 Standard No. 129; New non... rating; and specifies labeling requirements for non-pneumatic spare tires. S2Application. This standard...
49 CFR 571.129 - Standard No. 129; New non-pneumatic tires for passenger cars.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 49 Transportation 6 2011-10-01 2011-10-01 false Standard No. 129; New non-pneumatic tires for... VEHICLE SAFETY STANDARDS Federal Motor Vehicle Safety Standards § 571.129 Standard No. 129; New non... rating; and specifies labeling requirements for non-pneumatic spare tires. S2Application. This standard...
49 CFR 571.129 - Standard No. 129; New non-pneumatic tires for passenger cars.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 49 Transportation 6 2014-10-01 2014-10-01 false Standard No. 129; New non-pneumatic tires for... VEHICLE SAFETY STANDARDS Federal Motor Vehicle Safety Standards § 571.129 Standard No. 129; New non... rating; and specifies labeling requirements for non-pneumatic spare tires. S2Application. This standard...
49 CFR 571.129 - Standard No. 129; New non-pneumatic tires for passenger cars.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 49 Transportation 6 2012-10-01 2012-10-01 false Standard No. 129; New non-pneumatic tires for... VEHICLE SAFETY STANDARDS Federal Motor Vehicle Safety Standards § 571.129 Standard No. 129; New non... rating; and specifies labeling requirements for non-pneumatic spare tires. S2Application. This standard...
Precharged Pneumatic Soft Actuators and Their Applications to Untethered Soft Robots.
Li, Yunquan; Chen, Yonghua; Ren, Tao; Li, Yingtian; Choi, Shiu Hong
2018-06-20
The past decade has witnessed tremendous progress in soft robotics. Unlike most pneumatic-based methods, we present a new approach to soft robot design based on precharged pneumatics (PCP). We propose a PCP soft bending actuator, which is actuated by precharged air pressure and retracted by inextensible tendons. By pulling or releasing the tendons, the air pressure in the soft actuator is modulated, and hence, its bending angle. The tendons serve in a way similar to pressure-regulating valves that are used in typical pneumatic systems. The linear motion of tendons is transduced into complex motion via the prepressurized bent soft actuator. Furthermore, since a PCP actuator does not need any gas supply, complicated pneumatic control systems used in traditional soft robotics are eliminated. This facilitates the development of compact untethered autonomous soft robots for various applications. Both theoretical modeling and experimental validation have been conducted on a sample PCP soft actuator design. A fully untethered autonomous quadrupedal soft robot and a soft gripper have been developed to demonstrate the superiority of the proposed approach over traditional pneumatic-driven soft robots.
Wood, Billy E [Livermore, CA; Groves, Scott E [Brentwood, CA; Larsen, Greg J [Brentwood, CA; Sanchez, Roberto J [Pleasanton, CA
2006-11-14
A lightweight, small size, high sensitivity gauge for indirectly measuring displacement or absolute gap width by measuring axial strain in an orthogonal direction to the displacement/gap width. The gap gauge includes a preferably titanium base having a central tension bar with springs connecting opposite ends of the tension bar to a pair of end connector bars, and an elongated bow spring connected to the end connector bars with a middle section bowed away from the base to define a gap. The bow spring is capable of producing an axial strain in the base proportional to a displacement of the middle section in a direction orthogonal to the base. And a strain sensor, such as a Fabry-Perot interferometer strain sensor, is connected to measure the axial strain in the base, so that the displacement of the middle section may be indirectly determined from the measurement of the axial strain in the base.
Application of Model-based Prognostics to a Pneumatic Valves Testbed
NASA Technical Reports Server (NTRS)
Daigle, Matthew; Kulkarni, Chetan S.; Gorospe, George
2014-01-01
Pneumatic-actuated valves play an important role in many applications, including cryogenic propellant loading for space operations. Model-based prognostics emphasizes the importance of a model that describes the nominal and faulty behavior of a system, and how faulty behavior progresses in time, causing the end of useful life of the system. We describe the construction of a testbed consisting of a pneumatic valve that allows the injection of faulty behavior and controllable fault progression. The valve opens discretely, and is controlled through a solenoid valve. Controllable leaks of pneumatic gas in the testbed are introduced through proportional valves, allowing the testing and validation of prognostics algorithms for pneumatic valves. A new valve prognostics approach is developed that estimates fault progression and predicts remaining life based only on valve timing measurements. Simulation experiments demonstrate and validate the approach.
Hicks, Rodney W; Denholm, Bonnie
2013-10-01
Perioperative nurses are likely to encounter the use of pneumatic tourniquets in a variety of operative and invasive extremity procedures. Use of a pneumatic tourniquet offers an opportunity to obtain a near-bloodless surgical field; however, the use of tourniquets is not without risk. Unfavorable outcomes include pain, thrombotic events, nerve compression injuries, and disruption of skin integrity. Perioperative nurses should be familiar with the indications, contraindications, and changes in physiology associated with pneumatic tourniquet use. The revised AORN "Recommended practices for care of patients undergoing pneumatic tourniquet-assisted procedures" is focused on the perioperative nurse's role in patient care and provides guidance for developing, implementing, and evaluating practices that promote patient safety and improve the likelihood of positive outcomes. Copyright © 2013 AORN, Inc. Published by Elsevier Inc. All rights reserved.
Successful MPPF Pneumatics Verification and Validation Testing
2017-03-28
Engineers and technicians completed verification and validation testing of several pneumatic systems inside and outside the Multi-Payload Processing Facility (MPPF) at NASA's Kennedy Space Center in Florida. In view is the service platform for Orion spacecraft processing. To the left are several pneumatic panels. The MPPF will be used for offline processing and fueling of the Orion spacecraft and service module stack before launch. Orion also will be de-serviced in the MPPF after a mission. The Ground Systems Development and Operations Program (GSDO) is overseeing upgrades to the facility. The Engineering Directorate led the recent pneumatic tests.
Highly curved image sensors: a practical approach for improved optical performance
NASA Astrophysics Data System (ADS)
Guenter, Brian; Joshi, Neel; Stoakley, Richard; Keefe, Andrew; Geary, Kevin; Freeman, Ryan; Hundley, Jake; Patterson, Pamela; Hammon, David; Herrera, Guillermo; Sherman, Elena; Nowak, Andrew; Schubert, Randall; Brewer, Peter; Yang, Louis; Mott, Russell; McKnight, Geoff
2017-06-01
The significant optical and size benefits of using a curved focal surface for imaging systems have been well studied yet never brought to market for lack of a high-quality, mass-producible, curved image sensor. In this work we demonstrate that commercial silicon CMOS image sensors can be thinned and formed into accurate, highly curved optical surfaces with undiminished functionality. Our key development is a pneumatic forming process that avoids rigid mechanical constraints and suppresses wrinkling instabilities. A combination of forming-mold design, pressure membrane elastic properties, and controlled friction forces enables us to gradually contact the die at the corners and smoothly press the sensor into a spherical shape. Allowing the die to slide into the concave target shape enables a threefold increase in the spherical curvature over prior approaches having mechanical constraints that resist deformation, and create a high-stress, stretch-dominated state. Our process creates a bridge between the high precision and low-cost but planar CMOS process, and ideal non-planar component shapes such as spherical imagers for improved optical systems. We demonstrate these curved sensors in prototype cameras with custom lenses, measuring exceptional resolution of 3220 line-widths per picture height at an aperture of f/1.2 and nearly 100% relative illumination across the field. Though we use a 1/2.3" format image sensor in this report, we also show this process is generally compatible with many state of the art imaging sensor formats. By example, we report photogrammetry test data for an APS-C sized silicon die formed to a 30$^\\circ$ subtended spherical angle. These gains in sharpness and relative illumination enable a new generation of ultra-high performance, manufacturable, digital imaging systems for scientific, industrial, and artistic use.
Punkkinen, Henna; Merta, Elina; Teerioja, Nea; Moliis, Katja; Kuvaja, Eveliina
2012-10-01
Waste collection is one of the life cycle phases that influence the environmental sustainability of waste management. Pneumatic waste collection systems represent a new way of arranging waste collection in densely populated urban areas. However, limited information is available on the environmental impacts of this system. In this study, we compare the environmental sustainability of conventional door-to-door waste collection with its hypothetical pneumatic alternative. Furthermore, we analyse whether the size of the hypothetical pneumatic system, or the number of waste fractions included, have an impact on the results. Environmental loads are calculated for a hypothetical pneumatic waste collection system modelled on an existing dense urban area in Helsinki, Finland, and the results are compared to those of the prevailing, container-based, door-to-door waste collection system. The evaluation method used is the life-cycle inventory (LCI). In this study, we report the atmospheric emissions of greenhouse gases (GHG), SO(2) and NO(x). The results indicate that replacing the prevailing system with stationary pneumatic waste collection in an existing urban infrastructure would increase total air emissions. Locally, in the waste collection area, emissions would nonetheless diminish, as collection traffic decreases. While the electricity consumption of the hypothetical pneumatic system and the origin of electricity have a significant bearing on the results, emissions due to manufacturing the system's components prove decisive. Copyright © 2012 Elsevier Ltd. All rights reserved.
Figueroa, Jhon; Magaña, Sonia; Lim, Daniel V; Schlaf, Rudy
2012-12-14
The formation of a thin antibody film on a glass surface using pneumatic spray was investigated as a potential immobilization technique for capturing pathogenic targets. Goat-Escherichia coli O157:H7 IgG films were made by pneumatic spray and compared against the avidin-biotin bridge immobilized films by assaying with green fluorescent protein (GFP) transformed E. coli O157:H7 cells and fluorescent reporter antibodies. Functionality, stability, and immobilization of the films were tested. The pneumatic spray films had lower fluorescence intensity values than the avidin-biotin bridge films but resulted in similar detection for E. coli O157:H7 at 10(5)-10(7)cells/ml sample concentrations with no detection of non-E. coli O157:H7 strains. Both methods also resulted in similar percent capture efficiencies. The results demonstrated that immobilization of antibody via pneumatic spray did not render the antibody non-functional and produced stable antibody films. The amount of time necessary for immobilization of the antibody was reduced significantly from 24h for the avidin-biotin bridge to 7 min using the pneumatic spray technique, with additional benefits of greatly reduced use of materials and chemicals. The pneumatic spray technique promises to be an alternative for the immobilization of antibodies on glass slides for capturing pathogenic targets and use in biosensor type devices. Copyright © 2012. Published by Elsevier B.V.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-02-01
...-the-Road Tires From the People's Republic of China: Rescission of Countervailing Duty Administrative... countervailing duty order on certain new pneumatic off-the-road tires (OTR Tires) from the People's Republic of..., Office 6, ``Administrative Review of the Countervailing Duty Order on Certain New Pneumatic Off-the-road...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-06-01
...-the-Road Tires From the People's Republic of China: Extension of Preliminary Results of Antidumping... for the preliminary results of the administrative review of certain new pneumatic off-the-road tires... on certain new pneumatic off-the-road tires from the PRC. See Initiation of Antidumping and...
49 CFR 571.129 - Standard No. 129; New non-pneumatic tires for passenger cars.
Code of Federal Regulations, 2013 CFR
2013-10-01
...-pneumatic tire assembly incorporates a wheel, supports the tire, and attaches, either integrally or... directly or through a wheel or wheel center member, the vertical load and tractive forces from the roadway... assembly means a non-pneumatic tire, alone or in combination with a wheel or wheel center member, which can...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-08-04
... DEPARTMENT OF COMMERCE International Trade Administration (A-570-912) New Pneumatic Off-the-Road.... EFFECTIVE DATE: August 4, 2010. FOR FURTHER INFORMATION CONTACT: Andrea Staebler Berton or Raquel Silva, AD... review of the antidumping duty order on new pneumatic off-the-road tires (``OTR tires'') from the People...
NASA Astrophysics Data System (ADS)
Ferrara, T.; Howard, T. M.
2016-12-01
Studies attempting to reconcile facility level emission estimates of sources at oil and gas facilities with basin wide methane flux measurements have had limited success. Pneumatic devices are commonly used at oil and gas production facilities for process control or liquid pumping. These devices are powered by pressurized natural gas from the well, so they are known methane sources at these sites. Pneumatic devices are estimated to contribute 14% to 25% of the total greenhouse gas emissions (GHG) from production facilities. Measurements of pneumatic devices have shown that malfunctioning or poorly maintained control systems may be emitting significantly more methane than currently estimated. Emission inventories for these facilities use emission factors from EPA that are based on pneumatic device measurements made in the early 1990's. Recent studies of methane emissions from production facilities have attempted to measure emissions from pneumatic devices by several different methods. These methods have had limitations including alteration of the system being measured, the inability to distinguish between leaks and venting during normal operation, or insufficient response time to account of the time based emission events. We have developed a high speed recording high flow sampler that is capable of measuring the transient emissions from pneumatic devices. This sampler is based on the well-established high flow measurement technique used in oil and gas for quantifying component leak rates. In this paper we present the results of extensive laboratory controlled release testing. Additionally, test data from several field studies where this sampler has been used to measure pneumatic device emissions will be presented.
Microfluidic pressure amplifier circuits and electrostatic gates for pneumatic microsystems
Tice, Joshua D.; Bassett, Thomas A.; Desai, Amit V.; Apblett, Christopher A.; Kenis, Paul J. A.
2016-09-20
An electrostatic actuator is provide that can include a fluidic line, a first electrode, and a second electrode such that a gate chamber portion of the fluidic line is sandwiched between the first electrode and the second electrode. The electrostatic actuator can also include a pressure-balancing channel in fluid communication with the gate chamber portion where the first electrode is sandwiched between the pressure-balancing channel and the gate chamber portion. A pneumatic valve system is provided which includes an electrostatic gate and a fluidic channel fluidly separate from a fluidic control line. A pneumatic valve portion of the fluidic control line can be positioned relative to a portion of the fluidic channel such that expansion of the pneumatic valve portion restricts fluid flow through the fluidic channel. Methods of using an electrostatic actuator and a pneumatic valve system are also provided.
TOPICAL REVIEW: Pneumatic and hydraulic microactuators: a review
NASA Astrophysics Data System (ADS)
De Volder, Michaël; Reynaerts, Dominiek
2010-04-01
The development of MEMS actuators is rapidly evolving and continuously new progress in terms of efficiency, power and force output is reported. Pneumatic and hydraulic are an interesting class of microactuators that are easily overlooked. Despite the 20 years of research, and hundreds of publications on this topic, these actuators are only popular in microfluidic systems. In other MEMS applications, pneumatic and hydraulic actuators are rare in comparison with electrostatic, thermal or piezo-electric actuators. However, several studies have shown that hydraulic and pneumatic actuators deliver among the highest force and power densities at microscale. It is believed that this asset is particularly important in modern industrial and medical microsystems, and therefore, pneumatic and hydraulic actuators could start playing an increasingly important role. This paper shows an in-depth overview of the developments in this field ranging from the classic inflatable membrane actuators to more complex piston-cylinder and drag-based microdevices.
Throttle pneumatic impact mechanism equipped with afterburner idle-stroke chamber
NASA Astrophysics Data System (ADS)
Dedov, Alexey; Frantseva, Eleanor; Dmitriev, Mikhail
2017-01-01
Pneumatic impact mechanisms are widely used in construction, mining and other economic sectors of a country. Such mechanisms are a base for a wide range of machines of various types and dimensions from hand-held tools to mounted piling hammers with impact energy up to 10 000 J. This paper is aimed at creation of pneumatic impact mechanism with the improved characteristics, including operation, energy use, weight and size which is especially important in space-limited working conditions. The research methods include development of computer mathematical model that can solve equations system and test a prototype model at the experimental stand. As a result of conducted research the pneumatic impact mechanism with the improved characteristics was developed. An engineering method for calculating throttle pneumatic impact mechanisms with a preset value of impact energy from 1 to 20 000 was investigated. This method allows creating percussive machines of a wide range of application.
Imparting Motion to a Test Object Such as a Motor Vehicle in a Controlled Fashion
NASA Technical Reports Server (NTRS)
Southward, Stephen C. (Inventor); Reubush, Chandler (Inventor); Pittman, Bryan (Inventor); Roehrig, Kurt (Inventor); Gerard, Doug (Inventor)
2014-01-01
An apparatus imparts motion to a test object such as a motor vehicle in a controlled fashion. A base has mounted on it a linear electromagnetic motor having a first end and a second end, the first end being connected to the base. A pneumatic cylinder and piston combination have a first end and a second end, the first end connected to the base so that the pneumatic cylinder and piston combination is generally parallel with the linear electromagnetic motor. The second ends of the linear electromagnetic motor and pneumatic cylinder and piston combination being commonly linked to a mount for the test object. A control system for the linear electromagnetic motor and pneumatic cylinder and piston combination drives the pneumatic cylinder and piston combination to support a substantial static load of the test object and the linear electromagnetic motor to impart controlled motion to the test object.
Electron tunneling infrared sensor module with integrated control circuitry
NASA Technical Reports Server (NTRS)
Boyadzhyan-Sevak, Vardkes V. (Inventor)
2001-01-01
In an integrated electron tunneling sensor, an automatic tunneling control circuit varies a high voltage bias applied to the sensor deflection electrode in response to changes in sensor output to maintain the proper gap between the sensor tip and membrane. The control circuit ensures stable tunneling activity in the presence of large signals and other disturbances to the sensor. Output signals from the module may be derived from the amplified sensor output. The integrated sensor module is particularly well adapted for use in blood glucose measurement and monitoring system.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-04-30
... DEPARTMENT OF COMMERCE International Trade Administration [A-570-912] New Pneumatic Off-the-Road... the initiation of a new shipper review of the antidumping duty order on new pneumatic off-the-road... Off-the-Road Tires from the People's Republic of China: Initiation of New Shipper Review, 74 FR 56575...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-06-03
...-the-Road Tires From the People's Republic of China: Rescission of Antidumping Duty Administrative... order on certain new pneumatic off-the-road tires from the People's Republic of China (``PRC'') for the... antidumping duty order on certain new pneumatic off-the-road tires, with respect to the above-named companies...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-02-11
...-the-Road Tires From the People's Republic of China: Rescission of Countervailing Duty Administrative... countervailing duty order on certain new pneumatic off-the-road tires (OTR Tires) from the People's Republic of... withdrawal of its request for review. See Certain New Pneumatic Off-the-Road Tires From the People's Republic...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-01-25
... Tires From the People's Republic of China: Extension of Time Limit for Final Results of Countervailing... administrative review of the countervailing duty order on certain new pneumatic off-the-road tires from the People's Republic of China. See New Pneumatic Off-the-Road Tires From the People's Republic of China...
Preparation of the spacer for narrow electrode gap configuration in ionization-based gas sensor
DOE Office of Scientific and Technical Information (OSTI.GOV)
Saheed, Mohamed Shuaib Mohamed; Mohamed, Norani Muti; Burhanudin, Zainal Arif
2012-09-26
Carbon nanotubes (CNTs) have started to be developed as the sensing element for ionization-based gas sensors due to the demand for improved sensitivity, selectivity, stability and other sensing properties beyond what can be offered by the conventional ones. Although these limitations have been overcome, the problems still remain with the conventional ionization-based gas sensors in that they are bulky and operating with large breakdown voltage and high temperature. Recent studies have shown that the breakdown voltage can be reduced by using nanostructured electrodes and narrow electrode gap. Nanostructured electrode in the form of aligned CNTs array with evenly distributed nanotipsmore » can enhance the linear electric field significantly. The later is attributed to the shorter conductivity path through narrow electrode gap. The paper presents the study on the design consideration in order to realize ionization based gas sensor using aligned carbon nanotubes array in an optimum sensor configuration with narrow electrode gap. Several deposition techniques were studied to deposit the spacer, the key component that can control the electrode gap. Plasma spray deposition, electron beam deposition and dry oxidation method were employed to obtain minimum film thickness around 32 {mu}m. For plasma spray method, sand blasting process is required in order to produce rough surface for strong bonding of the deposited film onto the surface. Film thickness, typically about 39 {mu}m can be obtained. For the electron beam deposition and dry oxidation, the film thickness is in the range of nanometers and thus unsuitable to produce the spacer. The deposited multilayer film consisting of copper, alumina and ferum on which CNTs array will be grown was found to be removed during the etching process. This is attributed to the high etching rate on the thin film which can be prevented by reducing the rate and having a thicker conductive copper film.« less
A pneumatic Bionic Voice prosthesis-Pre-clinical trials of controlling the voice onset and offset.
Ahmadi, Farzaneh; Noorian, Farzad; Novakovic, Daniel; van Schaik, André
2018-01-01
Despite emergent progress in many fields of bionics, a functional Bionic Voice prosthesis for laryngectomy patients (larynx amputees) has not yet been achieved, leading to a lifetime of vocal disability for these patients. This study introduces a novel framework of Pneumatic Bionic Voice Prostheses as an electronic adaptation of the Pneumatic Artificial Larynx (PAL) device. The PAL is a non-invasive mechanical voice source, driven exclusively by respiration with an exceptionally high voice quality, comparable to the existing gold standard of Tracheoesophageal (TE) voice prosthesis. Following PAL design closely as the reference, Pneumatic Bionic Voice Prostheses seem to have a strong potential to substitute the existing gold standard by generating a similar voice quality while remaining non-invasive and non-surgical. This paper designs the first Pneumatic Bionic Voice prosthesis and evaluates its onset and offset control against the PAL device through pre-clinical trials on one laryngectomy patient. The evaluation on a database of more than five hours of continuous/isolated speech recordings shows a close match between the onset/offset control of the Pneumatic Bionic Voice and the PAL with an accuracy of 98.45 ±0.54%. When implemented in real-time, the Pneumatic Bionic Voice prosthesis controller has an average onset/offset delay of 10 milliseconds compared to the PAL. Hence it addresses a major disadvantage of previous electronic voice prostheses, including myoelectric Bionic Voice, in meeting the short time-frames of controlling the onset/offset of the voice in continuous speech.
A pneumatic Bionic Voice prosthesis—Pre-clinical trials of controlling the voice onset and offset
Noorian, Farzad; Novakovic, Daniel; van Schaik, André
2018-01-01
Despite emergent progress in many fields of bionics, a functional Bionic Voice prosthesis for laryngectomy patients (larynx amputees) has not yet been achieved, leading to a lifetime of vocal disability for these patients. This study introduces a novel framework of Pneumatic Bionic Voice Prostheses as an electronic adaptation of the Pneumatic Artificial Larynx (PAL) device. The PAL is a non-invasive mechanical voice source, driven exclusively by respiration with an exceptionally high voice quality, comparable to the existing gold standard of Tracheoesophageal (TE) voice prosthesis. Following PAL design closely as the reference, Pneumatic Bionic Voice Prostheses seem to have a strong potential to substitute the existing gold standard by generating a similar voice quality while remaining non-invasive and non-surgical. This paper designs the first Pneumatic Bionic Voice prosthesis and evaluates its onset and offset control against the PAL device through pre-clinical trials on one laryngectomy patient. The evaluation on a database of more than five hours of continuous/isolated speech recordings shows a close match between the onset/offset control of the Pneumatic Bionic Voice and the PAL with an accuracy of 98.45 ±0.54%. When implemented in real-time, the Pneumatic Bionic Voice prosthesis controller has an average onset/offset delay of 10 milliseconds compared to the PAL. Hence it addresses a major disadvantage of previous electronic voice prostheses, including myoelectric Bionic Voice, in meeting the short time-frames of controlling the onset/offset of the voice in continuous speech. PMID:29466455
Development of Pneumatic Robot Hand and Construction of Master-Slave System
NASA Astrophysics Data System (ADS)
Tsujiuchi, Nobutaka; Koizumi, Takayuki; Nishino, Shinya; Komatsubara, Hiroyuki; Kudawara, Tatsuwo; Hirano, Masanori
Recently, research and development has focused on robots that work in place of people. It is necessary for robots to perform the same flexible motions as people. Additionally, such robots need to incorporate high-level safety features in order not to injure people. For creation of such robots, we need to develop a robot hand that functions like a human hand. At the same time, this type of robot hand can be used as an artificial hand. Here, we present artificial muscle-type pneumatic actuators as the driving source of a robot hand that is both safe and flexible. Some development of robot hands using pneumatic actuators has already taken place. But, until now, when a pneumatic actuator is used, a big compressor is needed. So, the driving system also needs to be big; enlargement of the driving system is a major problem. Consequently, in this research, we develop a low-pressure, low-volume pneumatic actuator for driving a robot hand that works flexibly and safely on the assumption that it will be in contact with people. We develop a five-fingered robot hand with pneumatic actuators. And, we construct a master-slave system to enable the robot hand to perform the same operations as a human hand. We make a 1-link arm that has one degree of freedom using a pneumatic actuator, and construct a control system for the 1-link arm and verify its control performance.
Data rate enhancement of optical camera communications by compensating inter-frame gaps
NASA Astrophysics Data System (ADS)
Nguyen, Duy Thong; Park, Youngil
2017-07-01
Optical camera communications (OCC) is a convenient way of transmitting data between LED lamps and image sensors that are included in most smart devices. Although many schemes have been suggested to increase the data rate of the OCC system, it is still much lower than that of the photodiode-based LiFi system. One major reason of this low data rate is attributed to the inter-frame gap (IFG) of image sensor system, that is, the time gap between consecutive image frames. In this paper, we propose a way to compensate for this IFG efficiently by an interleaved Hamming coding scheme. The proposed scheme is implemented and the performance is measured.
Understanding International GNC Hardware Trends
NASA Technical Reports Server (NTRS)
Greenbaum, Adam; Brady, Tye; Dennehy, Cornelius; Airey, Stephen P.; Roelke, Evan; Judd, Samuel Brady
2015-01-01
An industry-wide survey of guidance, navigation and control (GNC) sensors, namely star trackers, gyros, and sun sensors was undertaken in 2014, in which size, mass, power, and various performance metrics were recorded for each category. A multidimensional analysis was performed, looking at the spectrum of available sensors, with the intent of identifying gaps in the available capability range. Mission types that are not currently well served by the available components were discussed, as well as some missions that would be enabled by filling gaps in the component space. This paper continues that study, with a focus on reaction wheels and magnetometers, as well as with updates to the listings of star trackers, gyros, and sun sensors. Also discussed are a framework for making the database available to the community at large, and the continued maintenance of this database and the analysis of its contents.
First Approach of Pneumatic Anthropomorphic Hand
2001-10-25
1 o f 3 FIRST APPROACH OF PNEUMATIC ANTHROPOMORPHIC HAND Jiménez, Omar; Leija, Lorenzo; Muñoz, Roberto Centro de Investigación y de Estudios...weight and minimum consumption, minimum control and natural appearance. Keywords- Anthropomorphic, hand, Pneumatic system, Prosthesis 1 . INTRODUCTION...The projects have been guided through an specific line of development. The project MARCUS[ 1 ] includes easiness as the most important aspect what
System for Dispensing a Precise Amount of Fluid
Benett, William J.; Krulevitch, Peter A.; Visuri, Steven R.; Dzenitis, John M.; Ness, Kevin D.
2008-08-12
A dispensing system delivers a precise amount of fluid for biological or chemical processing and/or analysis. Dispensing means moves the fluid. The dispensing means is operated by a pneumatic force. Connection means delivers the fluid to the desired location. An actuator means provides the pneumatic force to the dispensing means. Valving means transmits the pneumatic force from the actuator means to the dispensing means.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-02-22
...-the-Road Tires From the People's Republic of China: Notice of Second Extension of Time Limit for the... duty order on certain new pneumatic off-the-road tires (``off-the-road tires'') from the People's... on off- the-road tires from the PRC. See Certain New Pneumatic Off-the-Road Tires from the People's...
Benson, Roger B J; Butler, Richard J; Carrano, Matthew T; O'Connor, Patrick M
2012-02-01
Pneumatic (air-filled) postcranial bones are unique to birds among extant tetrapods. Unambiguous skeletal correlates of postcranial pneumaticity first appeared in the Late Triassic (approximately 210 million years ago), when they evolved independently in several groups of bird-line archosaurs (ornithodirans). These include the theropod dinosaurs (of which birds are extant representatives), the pterosaurs, and sauropodomorph dinosaurs. Postulated functions of skeletal pneumatisation include weight reduction in large-bodied or flying taxa, and density reduction resulting in energetic savings during foraging and locomotion. However, the influence of these hypotheses on the early evolution of pneumaticity has not been studied in detail previously. We review recent work on the significance of pneumaticity for understanding the biology of extinct ornithodirans, and present detailed new data on the proportion of the skeleton that was pneumatised in 131 non-avian theropods and Archaeopteryx. This includes all taxa known from significant postcranial remains. Pneumaticity of the cervical and anterior dorsal vertebrae occurred early in theropod evolution. This 'common pattern' was conserved on the line leading to birds, and is likely present in Archaeopteryx. Increases in skeletal pneumaticity occurred independently in as many as 12 lineages, highlighting a remarkably high number of parallel acquisitions of a bird-like feature among non-avian theropods. Using a quantitative comparative framework, we show that evolutionary increases in skeletal pneumaticity are significantly concentrated in lineages with large body size, suggesting that mass reduction in response to gravitational constraints at large body sizes influenced the early evolution of pneumaticity. However, the body size threshold for extensive pneumatisation is lower in theropod lineages more closely related to birds (maniraptorans). Thus, relaxation of the relationship between body size and pneumatisation preceded the origin of birds and cannot be explained as an adaptation for flight. We hypothesise that skeletal density modulation in small, non-volant, maniraptorans resulted in energetic savings as part of a multi-system response to increased metabolic demands. Acquisition of extensive postcranial pneumaticity in small-bodied maniraptorans may indicate avian-like high-performance endothermy. © 2011 The Authors. Biological Reviews © 2011 Cambridge Philosophical Society.
Hojoong Kim; Hyuntai Park; Jongwoo Kim; Kyu-Jin Cho; Yong-Lae Park
2017-07-01
Pneumatic artificial muscles (PAMs) are frequently used actuators in soft robotics due to their structural flexibility. They are generally characterized by the tensile force due to the axial contraction and the radial force with volume expansion. To date, most applications of P AMs have utilized axial contractions. In contrast, we propose a novel way to control radial expansions of particular P AMs using anisotropic behaviors. P AMs generally consist of a cylindrical rubber bladder that expands with injection of air and multiple flexible but inextensible strings or mesh that surround the bladder to generate axial contraction force. We propose methods of generating radial expansion force in two ways. One is to control the spatial density of the strings that hold the bladder, and the other is to give asymmetric patterns directly to the bladder for geometrical anisotropy. To evaluate the performance of the actuators, soft sensors made of a hyperelastic material and a liquid conductor were attached to the P AMs for measuring local strains and pressures of the PAMs. We also suggest use of the proposed PAMs to a wearable therapeutic device for treating text neck symptoms as an application. The P AMs were used to exert a pressure to the back of the neck to recover the original spinal alignment from the deformed shape.
Controllable pneumatic generator based on the catalytic decomposition of hydrogen peroxide
NASA Astrophysics Data System (ADS)
Kim, Kyung-Rok; Kim, Kyung-Soo; Kim, Soohyun
2014-07-01
This paper presents a novel compact and controllable pneumatic generator that uses hydrogen peroxide decomposition. A fuel micro-injector using a piston-pump mechanism is devised and tested to control the chemical decomposition rate. By controlling the injection rate, the feedback controller maintains the pressure of the gas reservoir at a desired pressure level. Thermodynamic analysis and experiments are performed to demonstrate the feasibility of the proposed pneumatic generator. Using a prototype of the pneumatic generator, it takes 6 s to reach 3.5 bars with a reservoir volume of 200 ml at the room temperature, which is sufficiently rapid and effective to maintain the repetitive lifting of a 1 kg mass.
Controllable pneumatic generator based on the catalytic decomposition of hydrogen peroxide.
Kim, Kyung-Rok; Kim, Kyung-Soo; Kim, Soohyun
2014-07-01
This paper presents a novel compact and controllable pneumatic generator that uses hydrogen peroxide decomposition. A fuel micro-injector using a piston-pump mechanism is devised and tested to control the chemical decomposition rate. By controlling the injection rate, the feedback controller maintains the pressure of the gas reservoir at a desired pressure level. Thermodynamic analysis and experiments are performed to demonstrate the feasibility of the proposed pneumatic generator. Using a prototype of the pneumatic generator, it takes 6 s to reach 3.5 bars with a reservoir volume of 200 ml at the room temperature, which is sufficiently rapid and effective to maintain the repetitive lifting of a 1 kg mass.
The qualitative assessment of pneumatic actuators operation in terms of vibration criteria
NASA Astrophysics Data System (ADS)
Hetmanczyk, M. P.; Michalski, P.
2015-11-01
The work quality of pneumatic actuators can be assessed in terms of multiple criteria. In the case of complex systems with pneumatic actuators retained at end positions (with occurrence of piston impact in cylinder covers) the vibration criteria constitute the most reliable indicators. The paper presents an impact assessment on the operating condition of the rodless pneumatic cylinder regarding to selected vibrational symptoms. On the basis of performed analysis the authors had shown meaningful premises allowing an evaluation of the performance and tuning of end position damping piston movement with usage the most common diagnostic tools (portable vibration analyzers). The presented method is useful in tuning of parameters in industrial conditions.
Tests of two new polyurethane foam wheelchair tires.
Gordon, J; Kauzlarich, J J; Thacker, J G
1989-01-01
The performance characteristics of four 24-inch wheelchair tires are considered; one pneumatic and three airless. Specifically, two new airless polyurethane foam tires (circular and tapered cross-section) were compared to both a molded polyisoprene tire and a rubber pneumatic tire. Rolling resistance, coefficient of static friction, spring rate, tire roll-off, impact absorption, wear resistance, and resistance to compression set were the characteristics considered for the basis of comparison. Although the pneumatic tire is preferred by many wheelchair users, the two new polyurethane foam tires were found to offer a performance similar to the high-pressure pneumatic tire. In addition, the foam tires are less expensive and lighter in weight than the other tires tested.
Microfluidic EBG Sensor Based on Phase-Shift Method Realized Using 3D Printing Technology.
Radonić, Vasa; Birgermajer, Slobodan; Kitić, Goran
2017-04-18
In this article, we propose a novel microfluidic microstrip electromagnetic band gap (EBG) sensor realized using cost-effective 3D printing technology. Microstrip sensor allows monitoring of the fluid properties flowing in the microchannel embedded between the microstrip line and ground plane. The sensor's operating principle is based on the phase-shift method, which allows the characterization at a single operating frequency of 6 GHz. The defected electromagnetic band gap (EBG) structure is realized as a pattern in the microstrip ground plane to improve sensor sensitivity. The designed microfluidic channel is fabricated using a fused deposition modelling (FDM) 3D printing process without additional supporting layers, while the conductive layers are realized using sticky aluminium tape. The measurement results show that the change of permittivity of the fluid in the microfluidic channel from 1 to 80 results in the phase-shift difference of almost 90°. The potential application is demonstrated through the implementation of a proposed sensor for the detection of toluene concentration in toluene-methanol mixture where various concentrations of toluene were analysed.
Analytical Solution to the Pneumatic Transient Rod System at ACRR
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fehr, Brandon Michael
2016-01-08
The ACRR pulse is pneumatically driven by nitrogen in a system of pipes, valves and hoses up to the connection of the pneumatic system and mechanical linkages of the transient rod (TR). The main components of the TR pneumatic system are the regulator, accumulator, solenoid valve and piston-cylinder assembly. The purpose of this analysis is to analyze the flow of nitrogen through the TR pneumatic system in order to develop a motion profile of the piston during the pulse and be able to predict the pressure distributions inside both the cylinder and accumulators. The predicted pressure distributions will be validatedmore » against pressure transducer data, while the motion profile will be compared to proximity switch data. By predicting the motion of the piston, pulse timing will be determined and provided to the engineers/operators for verification. The motion profile will provide an acceleration distribution to be used in Razorback to more accurately predict reactivity insertion into the system.« less
High-Torque, Lightweight, Pneumatically Driven Wrench For Small Spaces
NASA Technical Reports Server (NTRS)
Miller, Thomas W.
1995-01-01
Pneumatically driven wrench provides torque up to 3,000 lb. per ft. in small space. Designed to reach into 2.6 x 2.75 x 6 in. pocket. Weighs approximately 25 lbs. Includes reversible pneumatic motor (electric motor could be used instead) and slip clutch. Also includes device indicating total angle through which wrench turned bolt or nut. This feature used for turn-of-the-nut tightening method.
Inexpensive Dramatic Pneumatic Lift
NASA Astrophysics Data System (ADS)
Morse, Robert A.
2017-09-01
Various experiments and demonstrations relate air pressure and air pressure difference to force and area. Carpenter and Minnix describe a large-scale pneumatic lift in which a person sitting on a board atop a plastic garbage bag is lifted when the bag is connected to the exhaustport of a vacuum cleaner, which easily lifts the person. This article describes the construction and use of an inexpensive hand-held pneumatic lift to demonstrate the same principle.
Kozachenko, I N
2016-01-01
The classification of the injuries inflicted to the human body by gunshots from the pneumatic weapons remains to be developed. The objective of the present work was to elaborate the classification of the injuries caused by gunshots from the pneumatic weapons based on the analysis of 98 expert and acts of forensic medical expertises (surveys) of living subjects (n=76) and corpses (n=22) affected by gunshots from the pneumatic weapons. These materials were collected from the bureaus of forensic medical expertise in different regions of the Ukraine during the period from 2006 till 2015. In addition, scientific publications concerned with the problem of interest were used along with the relevant explanatory and terminological dictionaries. The terminology and the conceptual framework proposed by the author in the earlier papers provided a basis for the development of the first standard classification of the injuries inflicted to the human body by gunshots from the pneumatic weapons categorized into 15 groups. It is believed that this classification will lay the foundation for the common approach of forensic medical experts to the examination and analysis of the data on the gunshots from the pneumatic weapons used to be found on the bodies of living subjects and the corpses. Moreover, it may be useful for the clinicians in their diagnostic and therapeutic practices and for the legal practitioners engaged in the quality assessment of the results of forensic medical expertises. It is recommended to present information about the gunshots from the pneumatic weapons in the accounting documents in a separate line.
Paulus, David C; Schilling, Brian K
2009-01-01
The unloading of spaceflight leads to bone and muscle atrophy, and a pneumatic resistance squat exercise countermeasure has the potential to provide optimized controllable resistance in a lightweight and compact configuration. However each end of the barbell in the proposed device is connected to a separate resistance cylinder which could lead to bilaterally asymmetric loading. Therefore, the purpose of the study is to compare the unilateral ground reaction forces (GRF) of the new squat device compared to free weights. Four previously trained men (mean +/- SD; age = 20+/-2 years, body mass = 99+/-18 kg) performed three sets of three repetitions of maximal exertion squat exercises with pneumatically controlled constant resistance and free weights each with a resistance level set to half of the body weight of each subject. Unilateral GRF data for each lifting modality at the negative to positive transition of the squat exercise was measured with a force plate under each foot. The pneumatic resistance GRF (N; mean +/- SD) was 749+/-114 on the left leg and 786+/-123 on the right leg and the free weight GRF was 786+/-114 left and 861+/-111 right resulting in a 5% difference between left and right GRF with pneumatics and 9% difference with free weights. The correlation coefficient between left and right GRF was 0.92 with pneumatics and 0.80 with free weights. Because the pneumatic device elicited more bilaterally symmetric GRF than traditional free weights, the separate resistance cylinders are an acceptable design configuration.
Enema reduction of intussusception: the success rate of hydrostatic and pneumatic reduction.
Khorana, Jiraporn; Singhavejsakul, Jesda; Ukarapol, Nuthapong; Laohapensang, Mongkol; Wakhanrittee, Junsujee; Patumanond, Jayanton
2015-01-01
Intussusception is a common surgical emergency in infants and children. The incidence of intussusception is from one to four per 2,000 infants and children. If there is no peritonitis, perforation sign on abdominal radiographic studies, and nonresponsive shock, nonoperative reduction by pneumatic or hydrostatic enema can be performed. The purpose of this study was to compare the success rates of both the methods. Two institutional retrospective cohort studies were performed. All intussusception patients (ICD-10 code K56.1) who had visited Chiang Mai University Hospital and Siriraj Hospital from January 2006 to December 2012 were included in the study. The data were obtained by chart reviews and electronic databases, which included demographic data, symptoms, signs, and investigations. The patients were grouped according to the method of reduction followed into pneumatic reduction and hydrostatic reduction groups with the outcome being the success of the reduction technique. One hundred and seventy episodes of intussusception occurring in the patients of Chiang Mai University Hospital and Siriraj Hospital were included in this study. The success rate of pneumatic reduction was 61% and that of hydrostatic reduction was 44% (P=0.036). Multivariable analysis and adjusting of the factors by propensity scores were performed; the success rate of pneumatic reduction was 1.48 times more than that of hydrostatic reduction (P=0.036, 95% confidence interval [CI] =1.03-2.13). Both pneumatic and hydrostatic reduction can be performed safely according to the experience of the radiologist or pediatric surgeon and hospital setting. This study showed that pneumatic reduction had a higher success rate than hydrostatic reduction.
Rifai, Damhuji; Abdalla, Ahmed N; Razali, Ramdan; Ali, Kharudin; Faraj, Moneer A
2017-03-13
The use of the eddy current technique (ECT) for the non-destructive testing of conducting materials has become increasingly important in the past few years. The use of the non-destructive ECT plays a key role in the ensuring the safety and integrity of the large industrial structures such as oil and gas pipelines. This paper introduce a novel ECT probe design integrated with the distributed ECT inspection system (DSECT) use for crack inspection on inner ferromagnetic pipes. The system consists of an array of giant magneto-resistive (GMR) sensors, a pneumatic system, a rotating magnetic field excitation source and a host PC acting as the data analysis center. Probe design parameters, namely probe diameter, an excitation coil and the number of GMR sensors in the array sensor is optimized using numerical optimization based on the desirability approach. The main benefits of DSECT can be seen in terms of its modularity and flexibility for the use of different types of magnetic transducers/sensors, and signals of a different nature with either digital or analog outputs, making it suited for the ECT probe design using an array of GMR magnetic sensors. A real-time application of the DSECT distributed system for ECT inspection can be exploited for the inspection of 70 mm carbon steel pipe. In order to predict the axial and circumference defect detection, a mathematical model is developed based on the technique known as response surface methodology (RSM). The inspection results of a carbon steel pipe sample with artificial defects indicate that the system design is highly efficient.
Contraction Sensing with Smart Braid McKibben Muscles
Felt, Wyatt; Chin, Khai Yi; Remy, C. David
2016-01-01
The inherent compliance of soft fluidic actuators makes them attractive for use in wearable devices and soft robotics. Their flexible nature permits them to be used without traditional rotational or prismatic joints. Without these joints, however, measuring the motion of the actuators is challenging. Actuator-level sensors could improve the performance of continuum robots and robots with compliant or multi-degree-of-freedom joints. We make the reinforcing braid of a pneumatic artificial muscle (PAM or McKibben muscle) “smart” by weaving it from conductive, insulated wires. These wires form a solenoid-like circuit with an inductance that more than doubles over the PAM contraction. The reinforcing and sensing fibers can be used to measure the contraction of a PAM actuator with a simple, linear function of the measured inductance. Whereas other proposed self-sensing techniques rely on the addition of special elastomers or transducers, the technique presented in this work can be implemented without modifications of this kind. We present and experimentally validate two models for Smart Braid sensors based on the long solenoid approximation and the Neumann formula, respectively. We test a McKibben muscle made from a Smart Braid in quasistatic conditions with various end-loads and in dynamic conditions. We also test the performance of the Smart Braid sensor alongside steel. PMID:28503062
Use of pneumatic lithotripsy for managing difficult CBD calculi.
Farooq Qadri, Syed Javid; Khan, Muneer; Khan, Naveed
2011-01-01
About 7-12% of patients who harbor gallbladder calculi concomitant common bile duct (CBD) calculi are present. The treatment of gallbladder calculi has standardized in the form of laparoscopic cholecystectomy but management of CBD calculi is still evolving. Endoscopic removal of CBD calculi <2 cm in diameter is successful in 90-100% of cases but patients harboring stones >2 cm in diameter high failure rates can be seen. Traditionally, laparoscopically one can achieve success rate comparable to endoscopic surgery but large and impacted calculi may cause failures. If one uses pneumatic lithotripsy during laparoscopic management of CBD calculi one can achieve 100% stone clearance irrespective of size, degree of hardness and impaction. This study evaluates the feasibility of using pneumatic lithotripsy for CBD calculi. To our knowledge this is the 1st reported series of using pneumatic lithotripsy for CBD calculi. From June 2002 to June 2010 96 laparoscopic CBD explorations (LCBDE) were done for CBD calculi. Patients having choledocholithiasis with CBD diameter of >10 mm were taken for LCBDE while in patients with CBD diameter of <10 mm were referred for endoscopic clearance. Additionally ERCP failure cases were also subjected to LCBDE. Rigid nephroscope was used for LCBDE and usually calculi were removed by forceps only. In patients having large, hard &/or impacted calculi pneumatic lithotripsy were used for fragmentation. Out of the 96 patients in 12 (12.5%) cases pneumatic lithotripsy was used for stone fragmentation. Out of these 12 cases 5 (41.6%) were ERCP failure cases. At a mean hospital stay of 2.5 days 100% stone clearance was achieved in all cases with no perioperative complication. The present study shows how successfully pneumatic lithotripsy can be used to fragment large, hard &/or impacted CBD calculi. Pneumatic lithotripsy being user friendly easily available can reliably fragment CBD calculi in one session. Copyright © 2010 Surgical Associates Ltd. Published by Elsevier Ltd. All rights reserved.
Low, Jin-Huat; Yeow, Chen-Hua
2016-08-02
Soft compliant gripping is essential in delicate surgical manipulation for minimizing the risk of tissue grip damage caused by high stress concentrations at the point of contact. It can be achieved by complementing traditional rigid grippers with soft robotic pneumatic gripper devices. This manuscript describes a rod-based approach that combined both 3D-printing and a modified soft lithography technique to fabricate the soft pneumatic gripper. In brief, the pneumatic featureless mold with chamber component is 3D-printed and the rods were used to create the pneumatic channels that connect to the chamber. This protocol eliminates the risk of channels occluding during the sealing process and the need for external air source or related control circuit. The soft gripper consists of a chamber filled with air, and one or more gripper arms with a pneumatic channel in each arm connected to the chamber. The pneumatic channel is positioned close to the outer wall to create different stiffness in the gripper arm. Upon compression of the chamber which generates pressure on the pneumatic channel, the gripper arm will bend inward to form a close grip posture because the outer wall area is more compliant. The soft gripper can be inserted into a 3D-printed handling tool with two different control modes for chamber compression: manual gripper mode with a movable piston, and robotic gripper mode with a linear actuator. The double-arm gripper with two actuatable arms was able to pick up objects of sizes up to 2 mm and yet generate lower compressive forces as compared to elastomer-coated and non-coated rigid grippers. The feasibility of having other designs, such as single-arm or hook gripper, was also demonstrated, which further highlighted the customizability of the soft gripper device, and it's potential to be used in delicate surgical manipulation to reduce the risk of tissue grip damage.
International Instrumentation Symposium, 32nd, Seattle, WA, May 5-8, 1986, Proceedings
NASA Astrophysics Data System (ADS)
The conference presents papers on blast, shock, and vibration instrumentation; wind tunnel instrumentation and controls; electrooptic and fiber optic instrumentation; special test facilities; reentry vehicle testing; and nondestructive test and acoustic test instrumentation. Other topic include real time systems, flight test and avionics instrumentation, data aquisition and analysis systems, thermal measurements, and advances in measurement technology. Particular attention is given to an automated fringe counting laser interferometer for low frequency vibration measurements, dynamic pressure measurements in pneumatic lines, optically interfaced sensor system for aerospace applications, the picobalance for single microparticle measurements, ellipsometric film thickness, nanometer wear measurement by ultrathin surface layer activation, a rugged electronic scanner designed for turbine test, failure mechanism characterization of platinum alloy, and the thick film strain gage.
Condition monitoring of an electro-magnetic brake using an artificial neural network
NASA Astrophysics Data System (ADS)
Gofran, T.; Neugebauer, P.; Schramm, D.
2017-10-01
This paper presents a data-driven approach to Condition Monitoring of Electromagnetic brakes without use of additional sensors. For safe and efficient operation of electric motor a regular evaluation and replacement of the friction surface of the brake is required. One such evaluation method consists of direct or indirect sensing of the air-gap between pressure plate and magnet. A larger gap is generally indicative of worn surface(s). Traditionally this has been accomplished by the use of additional sensors - making existing systems complex, cost- sensitive and difficult to maintain. In this work a feed-forward Artificial Neural Network (ANN) is learned with the electrical data of the brake by supervised learning method to estimate the air-gap. The ANN model is optimized on the training set and validated using the test set. The experimental results of estimated air-gap with accuracy of over 95% demonstrate the validity of the proposed approach.
Bore, Thierry; Wagner, Norman; Lesoille, Sylvie Delepine; Taillade, Frederic; Six, Gonzague; Daout, Franck; Placko, Dominique
2016-04-18
Broadband electromagnetic frequency or time domain sensor techniques present high potential for quantitative water content monitoring in porous media. Prior to in situ application, the impact of the relationship between the broadband electromagnetic properties of the porous material (clay-rock) and the water content on the frequency or time domain sensor response is required. For this purpose, dielectric properties of intact clay rock samples experimental determined in the frequency range from 1 MHz to 10 GHz were used as input data in 3-D numerical frequency domain finite element field calculations to model the one port broadband frequency or time domain transfer function for a three rods based sensor embedded in the clay-rock. The sensor response in terms of the reflection factor was analyzed in time domain with classical travel time analysis in combination with an empirical model according to Topp equation, as well as the theoretical Lichtenecker and Rother model (LRM) to estimate the volumetric water content. The mixture equation considering the appropriate porosity of the investigated material provide a practical and efficient approach for water content estimation based on classical travel time analysis with the onset-method. The inflection method is not recommended for water content estimation in electrical dispersive and absorptive material. Moreover, the results clearly indicate that effects due to coupling of the sensor to the material cannot be neglected. Coupling problems caused by an air gap lead to dramatic effects on water content estimation, even for submillimeter gaps. Thus, the quantitative determination of the in situ water content requires careful sensor installation in order to reach a perfect probe clay rock coupling.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Alam, Maksudul M.; Sampathkumaran, Uma
The present invention relates to a modular chemiresistive sensor. In particular, a modular chemiresistive sensor for hypergolic fuel and oxidizer leak detection, carbon dioxide monitoring and detection of disease biomarkers. The sensor preferably has two gold or platinum electrodes mounted on a silicon substrate where the electrodes are connected to a power source and are separated by a gap of 0.5 to 4.0 .mu.M. A polymer nanowire or carbon nanotube spans the gap between the electrodes and connects the electrodes electrically. The electrodes are further connected to a circuit board having a processor and data storage, where the processor canmore » measure current and voltage values between the electrodes and compare the current and voltage values with current and voltage values stored in the data storage and assigned to particular concentrations of a pre-determined substance such as those listed above or a variety of other substances.« less
Studies of Neurofibromatosis-1 Modifier Genes
2005-06-01
inhibitors of GTPase activation by preventing the dissociation of GDP from the inactive GTPase. [E3 DDff The current dogma, at least in the context of...dissociation the cycle is less clear. inhibitors (GD/s), the activity of each of which is potentially modulated in response to various signals. Inactive...function No. of No. of No. of No. of No. of ArfGAPs RabGAPs RapGAPs RasGAPs RhoGAPs BAR IPR004148 Membrane curvature sensor 6 (4) 0 0 0 6 (6) BTK
NASA Astrophysics Data System (ADS)
Yang, Zhen; Zhang, Min; Liao, Yanbiao; Lai, Shurong; Tian, Qian; Li, Qisheng; Zhang, Yi; Zhuang, Zhi
2009-11-01
An extrinsic Fabry-Perot interferometric (EFPI) optical fiber hydrogen sensor based on palladium silver (Pd-Ag) film is designed for hydrogen leakage detection. A modified cross correlation signal processing method for an optical fiber EFPI hydrogen sensor is presented. As the applying of a special correlating factor which advises the effect on the fringe visibility of the gap length and wavelength, the cross correlation method has a high accuracy which is insensitive to light source power drift or changes in attenuation in the fiber, and the segment search method is employed to reduce computation and demodulating speed is fast. The Fabry-Perot gap length resolution of better than 0.2nm is achieved in a certain concentration of hydrogen.
Pneumatic fracturing of low permeability media
DOE Office of Scientific and Technical Information (OSTI.GOV)
Schuring, J.R.
1996-08-01
Pneumatic fracturing of soils to enhance the removal and treatment of dense nonaqueous phase liquids is described. The process involves gas injection at a pressure exceeding the natural stresses and at a flow rate exceeding the permeability of the formation. The paper outlines geologic considerations, advantages and disadvantages, general technology considerations, low permeability media considerations, commercial availability, efficiency, and costs. Five case histories of remediation using pneumatic fracturing are briefly summarized. 11 refs., 2 figs., 1 tab.
High-pressure portable pneumatic drive unit.
Hete, B F; Savage, M; Batur, C; Smith, W A; Golding, L A; Nosé, Y
1989-12-01
The left ventricular assist device (LVAD) of the Cleveland Clinic Foundation (CCF) is a single-chamber assist pump, driven by a high-pressure pneumatic cylinder. A low-cost, portable driver that will allow cardiac care patients, with a high-pressure pneumatic ventricle assist, more freedom of movement has been developed. The compact and light-weight configuration can provide periods of 2 h of freedom from a fixed position driver and does not use exotic technology.
Pneumatic Regolith Transfer Systems for In Situ Resource Utilization
NASA Technical Reports Server (NTRS)
Mueller, R. P.; Townsend, I. I.; Mantovani, J. G.; Zacny, Kris A.; Craft, Jack
2010-01-01
This slide presentation reviews the testing of a pneumatic system for transfering regolith, to be used for In Situ Resource Utilization (ISRU). Using both the simulated microgravity of parabolic flight and ground testing, the tests demonstrated that lunar regolith can be conveyed pneumatically into a simulated ISRU oxygen production plant reactor. The ground testing also demonstrated that the regolith can be expelled from the ISRU reactor for disposal or for other resource processing.
Weng, Kuo-Yao; Chou, Nien-Jen; Cheng, Jya-Wei
2008-07-01
An innovative vacuum capillary pneumatic actuation concept that can be used for point-of-care testing has been investigated. The vacuum glass capillaries are encapsulated within a laminated pouch and incorporated into the fluidic card. Vacuum glass capillaries broken by external force such as finger pressure, generate the pneumatic forces to induce liquid flow in the fluidic system. The sizes of vacuum capillary play a vital role in the pumping and metering functions of the system. The luteinizing hormone (LH) chromatographic immunoassay performances in the fluidic cards show consistency comparable to that obtained by manual micropipetting. The vacuum capillary pneumatic actuation will be applied in other complex handling step bioassays and lab-on-a-chip devices.
Powered Upper Limb Orthosis Actuation System Based on Pneumatic Artificial Muscles
NASA Astrophysics Data System (ADS)
Chakarov, Dimitar; Veneva, Ivanka; Tsveov, Mihail; Venev, Pavel
2018-03-01
The actuation system of a powered upper limb orthosis is studied in the work. To create natural safety in the mutual "man-robot" interaction, an actuation system based on pneumatic artificial muscles (PAM) is selected. Experimentally obtained force/contraction diagrams for bundles, consisting of different number of muscles are shown in the paper. The pooling force and the stiffness of the pneumatic actuators is assessed as a function of the number of muscles in the bundle and the supply pressure. Joint motion and torque is achieved by antagonistic actions through pulleys, driven by bundles of pneumatic muscles. Joint stiffness and joint torques are determined on condition of a power balance, as a function of the joint position, pressure, number of muscles and muscles
Improving travel information products via robust estimation techniques : final report, March 2009.
DOT National Transportation Integrated Search
2009-03-01
Traffic-monitoring systems, such as those using loop detectors, are prone to coverage gaps, arising from sensor noise, processing errors and : transmission problems. Such gaps adversely affect the accuracy of Advanced Traveler Information Systems. Th...
Wang, Yue; Gregory, Cherry; Minor, Mark A
2018-06-01
Molded silicone rubbers are common in manufacturing of soft robotic parts, but they are often prone to tears, punctures, and tensile failures when strained. In this article, we present a fabric compositing method for improving the mechanical properties of soft robotic parts by creating a fabric/rubber composite that increases the strength and durability of the molded rubber. Comprehensive ASTM material tests evaluating the strength, tear resistance, and puncture resistance are conducted on multiple composites embedded with different fabrics, including polyester, nylon, silk, cotton, rayon, and several blended fabrics. Results show that strong fabrics increase the strength and durability of the composite, valuable in pneumatic soft robotic applications, while elastic fabrics maintain elasticity and enhance tear strength, suitable for robotic skins or soft strain sensors. Two case studies then validate the proposed benefits of the fabric compositing for soft robotic pressure vessel applications and soft strain sensor applications. Evaluations of the fabric/rubber composite samples and devices indicate that such methods are effective for improving mechanical properties of soft robotic parts, resulting in parts that can have customized stiffness, strength, and vastly improved durability.
21 CFR 878.5910 - Pneumatic tourniquet.
Code of Federal Regulations, 2014 CFR
2014-04-01
...) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Therapeutic Devices § 878.5910 Pneumatic tourniquet... patient's limb and inflated to reduce or totally occlude circulation during surgery. (b) Classification...
21 CFR 878.5910 - Pneumatic tourniquet.
Code of Federal Regulations, 2012 CFR
2012-04-01
...) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Therapeutic Devices § 878.5910 Pneumatic tourniquet... patient's limb and inflated to reduce or totally occlude circulation during surgery. (b) Classification...
21 CFR 878.5910 - Pneumatic tourniquet.
Code of Federal Regulations, 2010 CFR
2010-04-01
...) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Therapeutic Devices § 878.5910 Pneumatic tourniquet... patient's limb and inflated to reduce or totally occlude circulation during surgery. (b) Classification...
21 CFR 878.5910 - Pneumatic tourniquet.
Code of Federal Regulations, 2013 CFR
2013-04-01
...) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Therapeutic Devices § 878.5910 Pneumatic tourniquet... patient's limb and inflated to reduce or totally occlude circulation during surgery. (b) Classification...
21 CFR 878.5910 - Pneumatic tourniquet.
Code of Federal Regulations, 2011 CFR
2011-04-01
...) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Therapeutic Devices § 878.5910 Pneumatic tourniquet... patient's limb and inflated to reduce or totally occlude circulation during surgery. (b) Classification...
Colucci, G; Giabbani, E; Barizzi, G; Urwyler, N; Alberio, L
2011-08-01
ROTEM(®) is considered a helpful point-of-care device to monitor blood coagulation. Centrally performed analysis is desirable but rapid transport of blood samples and real-time transmission of graphic results are an important prerequisite. The effect of sample transport through a pneumatic tube system on ROTEM(®) results is unknown. The aims of the present work were (i) to determine the influence of blood sample transport through a pneumatic tube system on ROTEM(®) parameters compared to manual transportation, and (ii) to verify whether graphic results can be transmitted on line via virtual network computing using local area network to the physician in charge of the patient. Single centre study with 30 normal volunteers. Two whole blood samples were transferred to the central haematology laboratory by either normal transport or pneumatic delivery. EXTEM, INTEM, FIBTEM and APTEM were analysed in parallel with two ROTEM(®) devices and compared. Connection between central laboratory, emergency and operating rooms was established using local area network. All collected ROTEM(®) parameters were within normal limits. No statistically significant differences between normal transport and pneumatic delivery were observed. Real-time transmission of the original ROTEM(®) curves using local area network is feasible and easy to establish. At our institution, transport of blood samples by pneumatic delivery does not influence ROTEM(®) parameters. Blood samples can be analysed centrally, and results transmitted live via virtual network computing to emergency or operating rooms. Prior to analyse blood samples centrally, the type of sample transport should be tested to exclude in vitro blood activation by local pneumatic transport system. © 2011 Blackwell Publishing Ltd.
Dosing Accuracy of Insulin Aspart FlexPens After Transport Through the Pneumatic Tube System.
Ward, Leah G; Heckman, Michael G; Warren, Amy I; Tran, Kimberly
2013-01-01
The purpose of this study was to evaluate whether transporting insulin aspart FlexPens via a pneumatic tube system affects the dosing accuracy of the pens. A total of 115 Novo Nordisk FlexPens containing insulin aspart were randomly assigned to be transported via a pneumatic tube system (n = 92) or to serve as the control (n = 23). Each pen was then randomized to 10 international unit (IU) doses (n = 25) or 30 IU doses (n = 67), providing 600 and 603 doses, respectively, for the pneumatic tube group. The control group also received random assignment to 10 IU doses (n = 6) or 30 IU doses (n = 17), providing 144 and 153 doses, respectively. Each dose was expelled using manufacturer instructions. Weights were recorded, corrected for specific gravity, and evaluated based on acceptable International Organization for Standardization (ISO) dosing limits. In the group of pens transported through the pneumatic tube system, none of the 600 doses of 10 IU (0.0%; 95% CI, 0.0 to 0.6) and none of the 603 doses of 30 IU (0.0%; 95% CI, 0.0 to 0.6) fell outside of the range of acceptable weights. Correspondingly, in the control group, none of the 144 doses at 10 IU (0.0%; 95% CI, 0.0 to 2.5) and none of the 153 doses at 30 IU (0.0%; 95% CI, 0.0 to 2.4) were outside of acceptable ISO limits. Transportation via pneumatic tube system does not appear to compromise dosing accuracy. Hospital pharmacies may rely on the pneumatic tube system for timely and accurate transport of insulin aspart FlexPens.
Cho, Nakwon
1980-01-01
A fast-acting valve actuator utilizes a spring driven pneumatically loaded piston to drive a valve gate. Rapid exhaust of pressurized gas from the pneumatically loaded side of the piston facilitates an extremely rapid piston stroke. A flexible selector diaphragm opens and closes an exhaust port in response to pressure differentials created by energizing and de-energizing a solenoid which controls the pneumatic input to the actuator as well as selectively providing a venting action to one side of the selector diaphragm.
Quigley, Alan James; Shannon, Helen
2013-01-01
Craniocervical bony pneumatization is a rare finding, with limited numbers of cases reported in the literature. It is thought to be linked to Eustachian tube dysfunction and a ball valve mechanism, and has a link with recurrent Valsalva maneuvers. We report a case of pneumatization of the occiput, atlas (C1) and axis (C2) in a patient with extensive ENT (Ear, Nose and Throat) surgical history who presented following a fall. Plain film, CT and MRI images are presented. PMID:24421950
Innovation-Prototype. Making hydraulic and/or pneumatic plates using 3D printing technology
NASA Astrophysics Data System (ADS)
Alexa, V.; Rațiu, S. A.; Kiss, I.; Cioată, V. G.; Rackov, M.
2018-01-01
Start 3D printing allows hydraulic and/or pneumatic plates to be obtained from a single technological process without requiring further post-production operations. 3D printing with innovative materials in a rich colour range has several advantages such as: time-saving, cost is the same for any type of plate and its reported just to volume, fast and impossible realization of hydraulic and/or pneumatic links compared to traditional and high accuracy technologies.
Intraluminal pneumatic lithotripsy for the removal of encrusted urinary catheters.
Canby-Hagino, E D; Caballero, R D; Harmon, W J
1999-12-01
Urologists frequently treat patients requiring long-term urinary drainage with a percutaneous nephrostomy tube or ureteral stent. When such tubes are neglected and become encrusted, removal challenges even experienced urologists. We describe a new, minimally invasive technique for safely and rapidly removing encrusted, occluded tubes using the Swiss Lithoclast pneumatic lithotriptor. Patients presenting with an encrusted urinary catheter were evaluated by excretory urography for renal function and obstruction. Gentle manual extraction of the tube was attempted, followed by traditional extracorporeal shock wave lithotripsy and/or ureteroscopy. When the tube was not extracted, patients were then treated with intraluminal insertion of a pneumatic lithotripsy probe. One patient presented with an encrusted, occluded nephrostomy tube and 2 had an encrusted, occluded, indwelling ureteral stent. None was removed by manual traction. Intraluminal encrustations prevented the pigtail portions of these tubes from uncoiling and removal. In each case a pneumatic lithotripsy probe was inserted into the lumen of the catheter and advanced in a jackhammer-like fashion. This technique resulted in disruption of the intraluminal encrustations and straightening of the tubes so that they were removed in an atraumatic manner. Intraluminal pneumatic lithotripsy is a safe, easy and rapid technique for removing encrusted urinary catheters. It is unique in that the pneumatic lithotripsy probe functions in an aqueous and nonaqueous environment, and dislodges intraluminal calcifications. We recommend its use as first line treatment for removing encrusted urinary catheters.
Cohen, Michael N; Baumal, Caroline R
2018-05-10
To report early formation and spontaneous closure of a full-thickness macular hole that developed after successful pneumatic retinopexy in a patient who had been undergoing treatment for diabetic macular edema. Case report of a 68-year-old man with bilateral nonproliferative diabetic retinopathy who was currently undergoing anti-vascular endothelial growth factor treatment for bilateral diabetic macular edema. On presentation, visual acuity was 20/200 in the left eye, and examination revealed a bullous, macula-off retinal detachment with a single horseshoe tear at 12 o'clock in the left eye. Pneumatic retinopexy was performed followed by laser augmentation 3 days later. Three weeks postoperatively, he returned with visual acuity of 20/50 and a full-thickness macular hole in the left eye. Although he elected for initial observation, he returned 2 weeks later with visual acuity of 20/50 in both eyes and a retinal detachment with a single break at 10 o'clock in the right eye. The macular hole in the left eye had spontaneously resolved. Pneumatic retinopexy was performed to the right eye. Over 1 year after bilateral pneumatic retinopexy, his retina remains without recurrence of a macular hole in the left eye. In the early postoperative period after pneumatic retinopexy to repair a retinal detachment, a macular hole can form and spontaneously close.
NASA Astrophysics Data System (ADS)
Qiu, Zhi-cheng; Shi, Ming-li; Wang, Bin; Xie, Zhuo-wei
2012-05-01
A rod cylinder based pneumatic driving scheme is proposed to suppress the vibration of a flexible smart beam. Pulse code modulation (PCM) method is employed to control the motion of the cylinder's piston rod for simultaneous positioning and vibration suppression. Firstly, the system dynamics model is derived using Hamilton principle. Its standard state-space representation is obtained for characteristic analysis, controller design, and simulation. Secondly, a genetic algorithm (GA) is applied to optimize and tune the control gain parameters adaptively based on the specific performance index. Numerical simulations are performed on the pneumatic driving elastic beam system, using the established model and controller with tuned gains by GA optimization process. Finally, an experimental setup for the flexible beam driven by a pneumatic rod cylinder is constructed. Experiments for suppressing vibrations of the flexible beam are conducted. Theoretical analysis, numerical simulation and experimental results demonstrate that the proposed pneumatic drive scheme and the adopted control algorithms are feasible. The large amplitude vibration of the first bending mode can be suppressed effectively.
La Ferrara, Vera; Rametta, Gabriella; De Maria, Antonella
2015-07-01
Interconnected network of nanostructured polyaniline (PANI) is giving strong potential for enhancing device performances than bulk PANI counterparts. For nanostructured device processing, the main challenge is to get prototypes on large area by requiring precision, low cost and high rate assembly. Among processes meeting these requests, the alternate current electric fields are often used for nanostructure assembling. For the first time, we show the assembly of nanostructured PANI onto large electrode gaps (30-60 μm width) by applying alternate current electric fields, at low frequencies, to PANI particles dispersed in acetonitrile (ACN). An important advantage is the short assembly time, limited to 5-10 s, although electrode gaps are microsized. That encouraging result is due to a combination of forces, such as dielectrophoresis (DEP), induced-charge electrokinetic (ICEK) flow and alternate current electroosmotic (ACEO) flow, which speed up the assembly process when low frequencies and large electrode gaps are used. The main achievement of the present study is the development of ammonia sensors created by direct assembling of nanostructured PANI onto electrodes. Sensors exhibit high sensitivity to low gas concentrations as well as excellent reversibility at room temperature, even after storage in air. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Neuhaus, J.E.
1992-10-13
A soil removal tool is provided for removing radioactive soil, rock and other debris from the bottom of an excavation, while permitting the operator to be located outside of a containment for that excavation. The tool includes a fixed jaw, secured to one end of an elongate pipe, which cooperates with a movable jaw pivotably mounted on the pipe. Movement of the movable jaw is controlled by a pneumatic cylinder mounted on the pipe. The actuator rod of the pneumatic cylinder is connected to a collar which is slidably mounted on the pipe and forms part of the pivotable mounting assembly for the movable jaw. Air is supplied to the pneumatic cylinder through a handle connected to the pipe, under the control of an actuator valve mounted on the handle, to provide movement of the movable jaw. 3 figs.
Neuhaus, John E.
1992-01-01
A soil removal tool is provided for removing radioactive soil, rock and other debris from the bottom of an excavation, while permitting the operator to be located outside of a containment for that excavation. The tool includes a fixed jaw, secured to one end of an elongate pipe, which cooperates with a movable jaw pivotably mounted on the pipe. Movement of the movable jaw is controlled by a pneumatic cylinder mounted on the pipe. The actuator rod of the pneumatic cylinder is connected to a collar which is slidably mounted on the pipe and forms part of the pivotable mounting assembly for the movable jaw. Air is supplied to the pneumatic cylinder through a handle connected to the pipe, under the control of an actuator valve mounted on the handle, to provide movement of the movable jaw.
Pneumatically Actuated Miniature Peristaltic Vacuum Pumps
NASA Technical Reports Server (NTRS)
Feldman, Sabrina; Feldman, Jason; Svehla, Danielle
2003-01-01
Pneumatically actuated miniature peristaltic vacuum pumps have been proposed for incorporation into advanced miniature versions of scientific instruments that depend on vacuum for proper operation. These pumps are expected to be capable of reaching vacuum-side pressures in the torr to millitorr range (from .133 down to .0.13 Pa). Vacuum pumps that operate in this range are often denoted roughing pumps. In comparison with previously available roughing pumps, these pumps are expected to be an order of magnitude less massive and less power-hungry. In addition, they would be extremely robust, and would operate with little or no maintenance and without need for oil or other lubricants. Portable mass spectrometers are typical examples of instruments that could incorporate the proposed pumps. In addition, the proposed pumps could be used as roughing pumps in general laboratory applications in which low pumping rates could be tolerated. The proposed pumps could be designed and fabricated in conventionally machined and micromachined versions. A typical micromachined version (see figure) would include a rigid glass, metal, or plastic substrate and two layers of silicone rubber. The bottom silicone layer would contain shallow pump channels covered by silicone arches that could be pushed down pneumatically to block the channels. The bottom silicone layer would be covered with a thin layer of material with very low gas permeability, and would be bonded to the substrate everywhere except in the channel areas. The top silicone layer would be attached to the bottom silicone layer and would contain pneumatic- actuation channels that would lie crosswise to the pump channels. This version is said to be micromachined because the two silicone layers containing the channels would be fabricated by casting silicone rubber on micromachined silicon molds. The pneumatic-actuation channels would be alternately connected to a compressed gas and (depending on pump design) either to atmospheric pressure or to a partial vacuum source. The design would be such that the higher pneumatic pressure would be sufficient to push the silicone arches down onto the substrates, blocking the channels. Thus, by connecting pneumatic- actuation channels to the two pneumatic sources in spatial and temporal alternation, waves of opening and closing, equivalent to peristalsis, could be made to move along the pump channels. A pump according to this concept could be manufactured inexpensively. Pneumatic sources (compressors and partial vacuum sources) similar those needed for actuation are commercially available; they typically have masses of .100 g and power demands of the order of several W. In a design-optimization effort, it should be possible to reduce masses and power demands below even these low levels and to integrate pneumatic sources along with the proposed pumps into miniature units with overall dimensions of no more than a few centimeters per side.
2011-03-08
pressure gauge on the pneumatic head and indicate the number of inches the water level was lowered in the well to induce the slug test. ERDC/CRREL...a pneumatic slug-test system and its major components. ERDC/CRREL TR-11-6 10 pressure gauge on the pneumatic head, which is graduated in inches...The water level changes induced by the slug test were measured with a 10-psi pressure transducer installed below the water level. An analog-to
Multichip imager with improved optical performance near the butt region
NASA Technical Reports Server (NTRS)
Kinnard, Kenneth P. (Inventor); Strong, Jr., Richard T. (Inventor); Goldfarb, Samuel (Inventor); Tower, John R. (Inventor)
1991-01-01
A compound imager consists of two or more individual chips, each with at least one line array of sensors thereupon. Each chip has a glass support plate attached to the side from which light reaches the line arrays. The chips are butted together end-to-end to make large line arrays of sensors. Because of imperfections in cutting, the butted surfaces define a gap. Light entering in the region of the gap is either lost or falls on an individual imager other than the one for which it is intended. This results in vignetting and/or crosstalk near the butted region. The gap is filled with an epoxy resin or other similar material which, when hardened, has an index of referaction near that of the glass support plate.
Microfluidic EBG Sensor Based on Phase-Shift Method Realized Using 3D Printing Technology
Radonić, Vasa; Birgermajer, Slobodan; Kitić, Goran
2017-01-01
In this article, we propose a novel microfluidic microstrip electromagnetic band gap (EBG) sensor realized using cost-effective 3D printing technology. Microstrip sensor allows monitoring of the fluid properties flowing in the microchannel embedded between the microstrip line and ground plane. The sensor’s operating principle is based on the phase-shift method, which allows the characterization at a single operating frequency of 6 GHz. The defected electromagnetic band gap (EBG) structure is realized as a pattern in the microstrip ground plane to improve sensor sensitivity. The designed microfluidic channel is fabricated using a fused deposition modelling (FDM) 3D printing process without additional supporting layers, while the conductive layers are realized using sticky aluminium tape. The measurement results show that the change of permittivity of the fluid in the microfluidic channel from 1 to 80 results in the phase-shift difference of almost 90°. The potential application is demonstrated through the implementation of a proposed sensor for the detection of toluene concentration in toluene–methanol mixture where various concentrations of toluene were analysed. PMID:28420217
Sensitivity enhancement of a surface plasmon resonance sensor using porous metamaterial layers
NASA Astrophysics Data System (ADS)
Cherifi, Abdellatif; Bouhafs, Benamar
2017-12-01
In this work, the surface plasmon resonance (SPR) device with two porous left handed metamaterial (LHM) layers separated by an insulator gap, is investigated. The effect of the insulator gap thickness and its refractive index (RI) on the angular response of the device is analyzed. The results show that the sensitivity of the SPR sensor is enhanced compared to the standard SPR sensors. Here, the multilayer structure is probed with 738 nm-wavelength, and electromagnetic properties of active porous LHM layers are described from the effective medium theory (EMT). Furthermore, in the increase of the porosity from 0 to 0.6, the designed nanocavity exhibits a fundamental SPR mode long-range (LR) type and it can be of interest in high-performance SPR sensing.
NASA Astrophysics Data System (ADS)
Bakir, Mehmet; Karaaslan, Muharrem; Dincer, Furkan; Delihacioglu, Kemal; Sabah, Cumali
2015-09-01
An electromagnetic (EM) energy harvesting application based on metamaterials is introduced. This application is operating at the the industrial, scientific, and medical band (2.40 GHz), which is especially chosen because of its wide usage area. A square ring resonator (SRR) which has two gaps and two resistors across the gaps on it is used. Chip resistors are used to deliver the power to any active component that requires power. Transmission and reflection characteristics of the metamaterial absorber for energy harvesting application are theoretically investigated and 83.6% efficient energy harvesting application is realized. To prove that this study can be used for different sensor applications other than harvesting, a temperature sensor configuration is developed that can be applied to other sensing applications.
Analysis and Derivation of Allocations for Fiber Contaminants in Liquid Bipropellant Systems
NASA Technical Reports Server (NTRS)
Lowrey, N. M; ibrahim, K. Y.
2012-01-01
An analysis was performed to identify the engineering rationale for the existing particulate limits in MSFC-SPEC-164, Cleanliness of Components for Use in Oxygen, Fuel, and Pneumatic Systems, determine the applicability of this rationale to fibers, identify potential risks that may result from fiber contamination in liquid oxygen/fuel bipropellant systems, and bound each of these risks. The objective of this analysis was to determine whether fiber contamination exceeding the established quantitative limits for particulate can be tolerated in these systems and, if so, to derive and recommend quantitative allocations for fibers beyond the limits established for other particulate. Knowledge gaps were identified that limit a complete understanding of the risk of promoted ignition from an accumulation of fibers in a gaseous oxygen system.
Bore, Thierry; Wagner, Norman; Delepine Lesoille, Sylvie; Taillade, Frederic; Six, Gonzague; Daout, Franck; Placko, Dominique
2016-01-01
Broadband electromagnetic frequency or time domain sensor techniques present high potential for quantitative water content monitoring in porous media. Prior to in situ application, the impact of the relationship between the broadband electromagnetic properties of the porous material (clay-rock) and the water content on the frequency or time domain sensor response is required. For this purpose, dielectric properties of intact clay rock samples experimental determined in the frequency range from 1 MHz to 10 GHz were used as input data in 3-D numerical frequency domain finite element field calculations to model the one port broadband frequency or time domain transfer function for a three rods based sensor embedded in the clay-rock. The sensor response in terms of the reflection factor was analyzed in time domain with classical travel time analysis in combination with an empirical model according to Topp equation, as well as the theoretical Lichtenecker and Rother model (LRM) to estimate the volumetric water content. The mixture equation considering the appropriate porosity of the investigated material provide a practical and efficient approach for water content estimation based on classical travel time analysis with the onset-method. The inflection method is not recommended for water content estimation in electrical dispersive and absorptive material. Moreover, the results clearly indicate that effects due to coupling of the sensor to the material cannot be neglected. Coupling problems caused by an air gap lead to dramatic effects on water content estimation, even for submillimeter gaps. Thus, the quantitative determination of the in situ water content requires careful sensor installation in order to reach a perfect probe clay rock coupling. PMID:27096865
Characterization of a piezoelectric valve for an adaptive pneumatic shock absorber
NASA Astrophysics Data System (ADS)
Mikułowski, Grzegorz; Wiszowaty, Rafał; Holnicki-Szulc, Jan
2013-12-01
This paper describes a pneumatic valve based on a multilayer piezoelectric actuator and Hörbiger plates. The device was designed to operate in an adaptive pneumatic shock absorber. The adaptive pneumatic shock absorber was considered as a piston-cylinder device and the valve was intended to be installed inside the piston. The main objective for the valve application was regulating the gas flow between the cylinder’s chambers in order to maintain the desired value of the reaction force generated by the shock absorber. The paper describes the design constraints and requirements, together with results of analytical modelling of fluid flow verified versus experimentally obtained data. The presented results indicate that the desired performance characteristics of the valve were obtained. The geometrical constraints of the flow ducts were studied and the actuator’s functional features analysed.
Powered glove with electro-pneumatic actuation unit for the disabled
NASA Astrophysics Data System (ADS)
Kawakami, Kosuke; Kumano, Shinichi; Moromugi, Shunji; Ishimatsu, Takakazu
2007-12-01
Authors have been developing a powered glove for people suffering from paralysis on their fingers to support their daily activity. Small air cylinders are used as actuators for this glove. Pneumatically-driven system has high advantages in case soft actuation is preferable. However, there are some problems to be solved in the pneumatically-driven system if the system is supposed to be used in our daily life. Huge air compressor is needed and solenoid valves emit loud sound for example. These problems are hurdles to commercialize the powered glove. To solve these problems authors have developed a new actuation unit by integrating an electric cylinder and an air cylinder. This actuation unit has advantages of both the electric actuation and the pneumatic actuation. Its advanced grip control ability has demonstrated through several experiments. The experimental results are reported in this paper.
Manzone, Marco; Balsari, Paolo; Marucco, Paolo; Tamagnone, Mario
2017-03-01
All maize drills produce a fine dust due to the seed coating abrasions that occur inside the seeding element. The air stream generated by the fan of pneumatic drills - necessary to create a depression in the sowing element of the machine and to guarantee correct seed deposition - can blow away the solid particles detached from the seeds. In order to reduce this phenomenon, a coated maize seeds company (Syngenta®) has set up an ad hoc dual-pipe deflector kit that easily fits different pneumatic drills (also old drills). In this study, the efficiency of this kit and the influence of different drill types on the kit's performance in reducing environmental pollution were evaluated using three different pneumatic seed drill models. The research showed that a dual-pipe deflector installed on a drill in standard configuration did not change the seeder performance, and by using this kit on pneumatic drills, irrespective of their design, it is possible to reduce by up to 69% the amount of dust drift in comparison with the conventional machine set-up. The dual-pipe deflector, under the conditions employed in the present experiments, showed good performance with all types of maize pneumatic drill used. Irrespective of the seeder model on which it is mounted, it is able to obtain similar results, indicating its high operational versatility. © 2016 Society of Chemical Industry. © 2016 Society of Chemical Industry.
Integration of Pneumatic Technology in Powered Mobility Devices
Daveler, Brandon; Wang, Hongwu; Gebrosky, Benjamin; Grindle, Garrett G.; Schneider, Urs
2017-01-01
Advances in electric motors, electronics, and control systems have enhanced the capability and drivability of electric power mobility devices over the last 60 years. Yet, battery technologies used in powered mobility devices (PMDs) have not kept pace. Recent advances in pneumatic technology, primarily the high torque, low speed design of rotary piston air motors, directly align with the needs of PMD. Pneumatic technology has advantages over battery-powered technology, including lighter weight, lower operating costs, decreased environmental impact, better reliability, and increased safety. Two prototypes were created that incorporated rotary piston air motors, high-pressure air tanks, and air-pressure regulators. Prototype 1 was created by modifying an existing electric PMD. Range tests were performed to determine the feasibility of pneumatic technology and the optimal combination of components to allow the longest range possible at acceptable speeds over ideal conditions. Using a 1.44 L air tank for feasibility testing, prototype 1 was capable of traveling 800 m, which confirmed the feasibility of pneumatic technology usage in PMDs. Prototype 2 was designed based on the testing results from prototype 1. After further optimization of prototype 2, the average maximum range was 3,150 m. Prototype 2 is up to 28.3% lighter than an equivalent size electric PMD and can be fully recharged in approximately 2 minutes. It decreases the cost of PMDs by approximately $1,500, because batteries do not need to be replaced over the lifetime of the device. The results provide justification for the use of pneumatic technology in PMDs. PMID:29339888
Integration of Pneumatic Technology in Powered Mobility Devices.
Daveler, Brandon; Wang, Hongwu; Gebrosky, Benjamin; Grindle, Garrett G; Schneider, Urs; Cooper, Rory A
2017-01-01
Advances in electric motors, electronics, and control systems have enhanced the capability and drivability of electric power mobility devices over the last 60 years. Yet, battery technologies used in powered mobility devices (PMDs) have not kept pace. Recent advances in pneumatic technology, primarily the high torque, low speed design of rotary piston air motors, directly align with the needs of PMD. Pneumatic technology has advantages over battery-powered technology, including lighter weight, lower operating costs, decreased environmental impact, better reliability, and increased safety. Two prototypes were created that incorporated rotary piston air motors, high-pressure air tanks, and air-pressure regulators. Prototype 1 was created by modifying an existing electric PMD. Range tests were performed to determine the feasibility of pneumatic technology and the optimal combination of components to allow the longest range possible at acceptable speeds over ideal conditions. Using a 1.44 L air tank for feasibility testing, prototype 1 was capable of traveling 800 m, which confirmed the feasibility of pneumatic technology usage in PMDs. Prototype 2 was designed based on the testing results from prototype 1. After further optimization of prototype 2, the average maximum range was 3,150 m. Prototype 2 is up to 28.3% lighter than an equivalent size electric PMD and can be fully recharged in approximately 2 minutes. It decreases the cost of PMDs by approximately $1,500, because batteries do not need to be replaced over the lifetime of the device. The results provide justification for the use of pneumatic technology in PMDs.
Soderdahl, D W; Henderson, S R; Hansberry, K L
1997-05-01
Intermittent pneumatic compression of the calf and/or thigh effectively decreases the incidence of deep venous thrombosis and other thrombotic sequelae but clinical data comparing these modalities are currently lacking. A total of 90 patients undergoing major urological surgery was randomly assigned to receive calf length or thigh length pneumatic compression for antithrombotic prophylaxis. Duplex ultrasound of the lower extremities was performed preoperatively and twice postoperatively to evaluate for deep venous thrombosis. Health care providers in the operating room, recovery room and ward were asked to compare the compression systems, and a cost analysis was performed. A total of 47 patients wore the thigh length sequential pneumatic sleeves and 43 wore calf length uniform compression systems. A pulmonary embolus without evidence of deep venous thrombosis was detected in 1 patient (2%) using the thigh length system. A thrombus was detected in the common femoral vein by duplex ultrasonography in 1 patient (2%) with the calf length system. Nursing personnel found the calf length sleeves easier to apply and more comfortable by patient account but they were satisfied with both systems. There was a significant cost savings with the calf length pneumatic compression system. Calf and thigh length pneumatic compression systems similarly decrease the risk of deep venous thrombosis in patients undergoing urological surgery. The calf length system has the added advantage of being less expensive and easier to use.
Rifai, Damhuji; Abdalla, Ahmed N.; Razali, Ramdan; Ali, Kharudin; Faraj, Moneer A.
2017-01-01
The use of the eddy current technique (ECT) for the non-destructive testing of conducting materials has become increasingly important in the past few years. The use of the non-destructive ECT plays a key role in the ensuring the safety and integrity of the large industrial structures such as oil and gas pipelines. This paper introduce a novel ECT probe design integrated with the distributed ECT inspection system (DSECT) use for crack inspection on inner ferromagnetic pipes. The system consists of an array of giant magneto-resistive (GMR) sensors, a pneumatic system, a rotating magnetic field excitation source and a host PC acting as the data analysis center. Probe design parameters, namely probe diameter, an excitation coil and the number of GMR sensors in the array sensor is optimized using numerical optimization based on the desirability approach. The main benefits of DSECT can be seen in terms of its modularity and flexibility for the use of different types of magnetic transducers/sensors, and signals of a different nature with either digital or analog outputs, making it suited for the ECT probe design using an array of GMR magnetic sensors. A real-time application of the DSECT distributed system for ECT inspection can be exploited for the inspection of 70 mm carbon steel pipe. In order to predict the axial and circumference defect detection, a mathematical model is developed based on the technique known as response surface methodology (RSM). The inspection results of a carbon steel pipe sample with artificial defects indicate that the system design is highly efficient. PMID:28335399
Speed Sensorless Induction Motor Drives for Electrical Actuators: Schemes, Trends and Tradeoffs
NASA Technical Reports Server (NTRS)
Elbuluk, Malik E.; Kankam, M. David
1997-01-01
For a decade, induction motor drive-based electrical actuators have been under investigation as potential replacement for the conventional hydraulic and pneumatic actuators in aircraft. Advantages of electric actuator include lower weight and size, reduced maintenance and operating costs, improved safety due to the elimination of hazardous fluids and high pressure hydraulic and pneumatic actuators, and increased efficiency. Recently, the emphasis of research on induction motor drives has been on sensorless vector control which eliminates flux and speed sensors mounted on the motor. Also, the development of effective speed and flux estimators has allowed good rotor flux-oriented (RFO) performance at all speeds except those close to zero. Sensorless control has improved the motor performance, compared to the Volts/Hertz (or constant flux) controls. This report evaluates documented schemes for speed sensorless drives, and discusses the trends and tradeoffs involved in selecting a particular scheme. These schemes combine the attributes of the direct and indirect field-oriented control (FOC) or use model adaptive reference systems (MRAS) with a speed-dependent current model for flux estimation which tracks the voltage model-based flux estimator. Many factors are important in comparing the effectiveness of a speed sensorless scheme. Among them are the wide speed range capability, motor parameter insensitivity and noise reduction. Although a number of schemes have been proposed for solving the speed estimation, zero-speed FOC with robustness against parameter variations still remains an area of research for speed sensorless control.
Monitoring of Bio-signal of People on Flooring, Tatami and in Bathtub, Toilet
NASA Astrophysics Data System (ADS)
Kurihara, Yosuke; Kawanishi, Yoshihiro; Watanabe, Kajiro; Kobayashi, Kazuyuki; Tanaka, Hiroshi
In the graying Japanese society, monitoring health-related human data with sensors embedded in the living environment is quite meaningful in terms of emergency response and of long-term health management. In using the body data monitoring system daily at home, the lack of invasiveness during the monitoring and the maintenance of the system are of great importance. We have proposed the method to surmise the sleep stages of sleeping subjects by measuring the heartbeats and the respirations without invasiveness using the pneumatic method with an air mattress. This method, however, has a problem in the maintenance, since it requires periodic refilling of the air into the mattress. In this paper, another pneumatic method, which applies silicon tubes instead of the air mattress, is proposed. The change of S/N ratio in heartbeat and respiration signals, while having the environmental noises increased, are compared among a room with wooden flooring, another with tatami mats, a bath tub, and a toilet room. The result shows that both the pulse waves and the breaths can be measured with the accuracy of around 30dB, and the identification of each pulse from among the pulse waves is also feasible, under the condition that the environmental noises in the room with wooden flooring, that with tatami mats, the bath tub, and the rest room are 0.01G, 0.09G, 100ml, and 0.01G respectively.
Design and characterization of a biologically inspired quasi-passive prosthetic ankle-foot.
Mooney, Luke M; Lai, Cara H; Rouse, Elliott J
2014-01-01
By design, commonly worn energy storage and release (ESR) prosthetic feet cannot provide biologically realistic ankle joint torque and angle profiles during walking. Additionally, their anthropomorphic, cantilever architecture causes their mechanical stiffness to decrease throughout the stance phase of walking, opposing the known trend of the biological ankle. In this study, the design of a quasi-passive pneumatic ankle-foot prosthesis is detailed that is able to replicate the biological ankle's torque and angle profiles during walking. The prosthetic ankle is comprised of a pneumatic piston, bending spring and solenoid valve. The mechanical properties of the pneumatic ankle prosthesis are characterized using a materials testing machine and the properties are compared to those from a common, passive ESR prosthetic foot. The characterization spanned a range of ankle equilibrium pressures and testing locations beneath the foot, analogous to the location of center of pressure within the stance phase of walking. The pneumatic ankle prosthesis was shown to provide biologically appropriate trends and magnitudes of torque, angle and stiffness behavior, when compared to the passive ESR prosthetic foot. Future work will focus on the development of a control system for the quasi-passive device and clinical testing of the pneumatic ankle to demonstrate efficacy.
Pressurization, Pneumatic, and Vent Subsystems of the X-34 Main Propulsion System
NASA Technical Reports Server (NTRS)
Hedayat, A.; Steadman, T. E.; Brown, T. M.; Knight, K. C.; White, C. E., Jr.; Champion, R. H., Jr.
1998-01-01
In pressurization systems, regulators and orifices are use to control the flow of the pressurant. For the X-34 Main Propulsion System, three pressurization subsystem design configuration options were considered. In the first option, regulators were used while in the other options, orifices were considered. In each design option, the vent/relief system must be capable of relieving the pressurant flow without allowing the tank pressure to rise above proof, therefore, impacts on the propellant tank vent system were investigated and a trade study of the pressurization system was conducted. The analysis indicated that design option using regulators poses least risk. Then, a detailed transient thermal/fluid analysis of the recommended pressurization system was performed. Helium usage, thermodynamic conditions, and overpressurization of each propellant tank were evaluated. The pneumatic and purge subsystem is used for pneumatic valve actuation, Inter-Propellant Seal purges, Engine Spin Start, and engine purges at the required interface pressures, A transient analysis of the pneumatic and purge subsystem provided helium usage and flow rates to Inter-Propellant Seal and engine interfaces. Fill analysis of the helium bottles of pressurization and pneumatic subsystems during ground operation was performed. The required fill time and the stored
Field demonstration of two pneumatic backfilling technologies
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dyni, R.C.; Burnett, M.; Philbin, D.
1995-12-31
This US Bureau of Mines (USBM) report summarizes a field demonstration of pneumatic backfilling technologies conducted at the abandoned Hillside Coal and Iron Slope in Vandling, PA. Researchers demonstrated two pneumatic backfilling technologies recently developed under the USBM`s Abandoned Mine Reclamation Research Program, the Pneumatic Pipefeeder and the High-Efficiency Ejector. Both systems had previously been evaluated at the USBM`s subsidence abatement investigation laboratory near Fairchance, PA. The objective of the demonstration was to fill 100% of the abandoned tunnel with backfill stone to prevent further subsidence. The pneumatic Pipefeeder was used for 21 days, at a rate of 63 tomore » 124 t/d (69 to 136 st/d), to fill 88% of the tunnel. The High-Efficiency Ejector was used for 2 days, at a rate of 125 to 132 T/d (138 to 146 st/d) to fill the remaining 12% of the tunnel. The backfill placed by both systems was tightly compacted. The major problem encountered was wear on the polyethylene pipeline from the abrasion of the high-velocity backfill. The use of heavier steel pipe minimized the problem. A cost analysis for the entire project is given.« less
Romero, Louis A.; Torczynski, John R.; Clausen, Jonathan R.; ...
2015-11-16
Herein, we show how introducing a small amount of gas can completely change the motion of a solid object in a viscous liquid during vibration. We analyze an idealized system exhibiting this behavior: a piston moving in a liquid-filled housing, where the gaps between the piston and the housing are narrow and depend on the piston position. Recent experiments have shown that vibration causes some gas to move below the piston and the piston to subsequently move downward and compress its supporting spring. Herein, we analyze the analogous but simpler situation in which the gas regions are replaced by bellowsmore » with similar pressure-volume relationships. We show that these bellows form a spring (analogous to the pneumatic spring formed by the gas regions) which enables the piston and the liquid to oscillate in a mode that does not exist without this spring. This mode is referred to here as the Couette mode because the liquid in the gaps moves essentially in Couette flow (i.e., with almost no component of Poiseuille flow). Since Couette flow by itself produces extremely low damping, the Couette mode has a strong resonance. We show that, near this resonance, the dependence of the gap geometry on the piston position produces a large rectified (net) force on the piston during vibration. As a result, this force can be much larger than the piston weight and the strength of its supporting spring and is in the direction that decreases the flow resistance of the gap geometry.« less
Inflatable device for installing strain gage bridges
NASA Technical Reports Server (NTRS)
Cook, C. E.; Smith, G. E.; Monaghan, R. C. (Inventor)
1983-01-01
Methods and devices for installing in a tubular shaft multiple strain gages are disclosed with focus on a method and a device for pneumatically forcing strain gages into seated engagement with the internal surfaces of a tubular shaft in an installation of multiple strain gages in a tubular shaft. The strain gages or other electron devices are seated in a template-like component which is wrapped about a pneumatically expansible body. The component is inserted into a shaft and the body is pneumatically expanded after a suitable adhesive was applied to the surfaces.
Successful MPPF Pneumatics Verification and Validation Testing
2017-03-28
Engineers and technicians completed verification and validation testing of several pneumatic systems inside and outside the Multi-Payload Processing Facility (MPPF) at NASA's Kennedy Space Center in Florida. In view is the service platform for Orion spacecraft processing. The MPPF will be used for offline processing and fueling of the Orion spacecraft and service module stack before launch. Orion also will be de-serviced in the MPPF after a mission. The Ground Systems Development and Operations Program (GSDO) is overseeing upgrades to the facility. The Engineering Directorate led the recent pneumatic tests.
Successful MPPF Pneumatics Verification and Validation Testing
2017-03-28
Engineers and technicians completed verification and validation testing of several pneumatic systems inside and outside the Multi-Payload Processing Facility (MPPF) at NASA's Kennedy Space Center in Florida. In view is the top level of the service platform for Orion spacecraft processing. The MPPF will be used for offline processing and fueling of the Orion spacecraft and service module stack before launch. Orion also will be de-serviced in the MPPF after a mission. The Ground Systems Development and Operations Program (GSDO) is overseeing upgrades to the facility. The Engineering Directorate led the recent pneumatic tests.
Tuning the Energy Gap of SiCH3 Nanomaterials Under Elastic Strain
NASA Astrophysics Data System (ADS)
Ma, Shengqian; Li, Feng; Geng, Jiguo; Zhu, Mei; Li, Suyan; Han, Juguang
2018-05-01
SiCH3 nanomaterials have been studied using the density functional theory. When the nanosheets and nanoribbons (armchair and zigzag) are introduced, their energy gap is modulated under elastic strain and width. The results show that the band gap of SiCH3 nanomaterials can be easily tuned using elastic strains and widths. Surprisingly, the band gap can be modulated along two directions, namely, compressing and stretching. The band gap decreases when increasing stretching strain or decreasing compressing strain. In addition, the band gap decreases when increasing the nanoribbon width. For energy gap engineering, the band gap can be tuned by strains and widths. Therefore, the SiCH3 nanomaterials play important roles in potential applications for strain sensors, electronics, and optical electronics.
Treatment of ureteric calculi--use of Holmium: YAG laser lithotripsy versus pneumatic lithoclast.
Tipu, Salman Ahmed; Malik, Hammad Afzal; Mohhayuddin, Nazim; Sultan, Gauhar; Hussain, Manzoor; Hashmi, Altaf; Naqvi, Syed Ali Anwar; Rizvi, Syed Adibul Hasan
2007-09-01
To compare the efficacy of Holmium: YAG laser and pneumatic lithoclast in treating ureteric calculi. The study included total of 100 patients divided into two equal groups of laser lithotripsy (LL) and pneumatic lithoclast (PL). Study was conducted between September 2006 and February 2007. Inclusion criteria were patients with a ureteric stone of size 1-2 cm and negative urine culture. An x-ray KUB was mandatory. IVU and CT pyelogram were also done when required. Procedures were done under general anaesthesia after a single dose of pre-operative antibiotic. A 7.5 Fr semi rigid ureteroscope was used for ureteroscopy in all cases. Holmium: YAG laser with 365 microm wide probe was employed in laser group and frequency was set between 5 and 10 Hz at a power of 10 to 15 W. Swiss lithoclast with single or multiple fire technique was used accordingly in PL group. Postoperatively patients underwent radiography and helical CT as required at 4th week of follow up to asses stone clearance. The mean patient age in LL and PL group was 38 +/- 10 and 40 +/- 10 years respectively. The male to female ratio and stone size were similar between the groups. Stone migration up in pelvicalyceal system occurred in two patients of LL group while in eight patients of PL group. JJ Stent was placed in 5(10%) patients in laser group where as 13 (26%) patients required it in pneumatic lithoclast group. Stone free rate at 4 weeks was 92% in laser group as compared to 82% in pneumatic lithoclast group. Hospital stay was more than 24 hours in 2 patients of laser group as compared to 5 patients of pneumatic lithoclast group. Complication rate was 4% in LL group whereas it was 14% in PL group. Holmium: YAG laser lithotripsy is a superior technology compared to pneumatic lithoclast in terms of rate of stone clearance and complications, especially in upper ureteric stones.
Spot-Welding Gun With Adjustable Pneumatic Spring
NASA Technical Reports Server (NTRS)
Burley, Richard K.
1990-01-01
Proposed spot-welding gun equipped with pneumatic spring, which could be bellows or piston and cylinder, exerts force independent of position along stroke. Applies accurate controlled force to joint welded, without precise positioning at critical position within stroke.
Raĭzberg, S A; Makarov, I Iu; Lorents, A S
2014-01-01
The objective of the present work was to elucidate the structural characteristics of the 9.0 mm pneumatic rifle and three regular types of the bullets differing in the head shape fired from it. Morphological features of the injuries inflicted by such bullets are described in conjunction with the peculiarities of precipitation of the shot products in their projection as the prerequisites for their objective differentiation. Results: The study allowed to reveal the composition of the gunshot residues and to determine the maximum distance of their distribution. The specific features of experimental damage inflicted by the shots from the 9.0 mm pneumatic rifle to the coarse white calico fabric targets were shown to depend on the shot range. The objective signs of the so-called "short-range" shot from the 9.0 mm pneumatic rifle were described for the first time.
Torque characteristics of a 122-centimeter butterfly valve with a hydro/pneumatic actuator
NASA Technical Reports Server (NTRS)
Lin, F. N.; Moore, W. I.; Lundy, F. E.
1981-01-01
Actuating torque data from field testing of a 122-centimeter (48 in.) butterfly valve with a hydro/pneumatic actuator is presented. The hydraulic cylinder functions as either a forward or a reverse brake. Its resistance torque increases when the valve speeds up and decreases when the valve slows down. A reduction of flow resistance in the hydraulic flow path from one end of the hydraulic cylinder to the other will effectively reduce the hydraulic resistance torque and hence increase the actuating torque. The sum of hydrodynamic and friction torques (combined resistance torque) of a butterfly valve is a function of valve opening time. An increase in the pneumatic actuating pressure will result in a decrease in both the combined resistance torque and the actuator opening torque; however, it does shorten the valve opening time. As the pneumatic pressure increases, the valve opening time for a given configuration approaches an asymptotical value.
An Ankle-Foot Orthosis Powered by Artificial Pneumatic Muscles
Ferris, Daniel P.; Czerniecki, Joseph M.; Hannaford, Blake
2005-01-01
We developed a pneumatically powered orthosis for the human ankle joint. The orthosis consisted of a carbon fiber shell, hinge joint, and two artificial pneumatic muscles. One artificial pneumatic muscle provided plantar flexion torque and the second one provided dorsiflexion torque. Computer software adjusted air pressure in each artificial muscle independently so that artificial muscle force was proportional to rectified low-pass-filtered electromyography (EMG) amplitude (i.e., proportional myoelectric control). Tibialis anterior EMG activated the artificial dorsiflexor and soleus EMG activated the artificial plantar flexor. We collected joint kinematic and artificial muscle force data as one healthy participant walked on a treadmill with the orthosis. Peak plantar flexor torque provided by the orthosis was 70 Nm, and peak dorsiflexor torque provided by the orthosis was 38 Nm. The orthosis could be useful for basic science studies on human locomotion or possibly for gait rehabilitation after neurological injury. PMID:16082019
Multifuctional integrated sensors (MFISES).
DOE Office of Scientific and Technical Information (OSTI.GOV)
Homeijer, Brian D.; Roozeboom, Clifton
2015-10-01
Many emerging IoT applications require sensing of multiple physical and environmental parameters for: completeness of information, measurement validation, unexpected demands, improved performance. For example, a typical outdoor weather station measures temperature, humidity, barometric pressure, light intensity, rainfall, wind speed and direction. Existing sensor technologies do not directly address the demand for cost, size, and power reduction in multi-paramater sensing applications. Industry sensor manufacturers have developed integrated sensor systems for inertial measurements that combine accelerometers, gyroscopes, and magnetometers, but do not address environmental sensing functionality. In existing research literature, a technology gap exists between the functionality of MEMS sensors and themore » real world applications of the sensors systems.« less
Tunneling magnetoresistance sensor with pT level 1/f magnetic noise
NASA Astrophysics Data System (ADS)
Deak, James G.; Zhou, Zhimin; Shen, Weifeng
2017-05-01
Magnetoresistive devices are important components in a large number of commercial electronic products in a wide range of applications including industrial position sensors, automotive sensors, hard disk read heads, cell phone compasses, and solid state memories. These devices are commonly based on anisotropic magnetoresistance (AMR) and giant magnetoresistance (GMR), but over the past few years tunneling magnetoresistance (TMR) has been emerging in more applications. Here we focus on recent work that has enabled the development of TMR magnetic field sensors with 1/f noise of less than 100 pT/rtHz at 1 Hz. Of the commercially available sensors, the lowest noise devices have typically been AMR, but they generally have the largest die size. Based on this observation and modeling of experimental data size and geometry dependence, we find that there is an optimal design rule that produces minimum 1/f noise. This design rule requires maximizing the areal coverage of an on-chip flux concentrator, providing it with a minimum possible total gap width, and tightly packing the gaps with MTJ elements, which increases the effective volume and decreases the saturation field of the MTJ freelayers. When properly optimized using this rule, these sensors have noise below 60 pT/rtHz, and could possibly replace fluxgate magnetometers in some applications.
Real-time method for establishing a detection map for a network of sensors
Nguyen, Hung D; Koch, Mark W; Giron, Casey; Rondeau, Daniel M; Russell, John L
2012-09-11
A method for establishing a detection map of a dynamically configurable sensor network. This method determines an appropriate set of locations for a plurality of sensor units of a sensor network and establishes a detection map for the network of sensors while the network is being set up; the detection map includes the effects of the local terrain and individual sensor performance. Sensor performance is characterized during the placement of the sensor units, which enables dynamic adjustment or reconfiguration of the placement of individual elements of the sensor network during network set-up to accommodate variations in local terrain and individual sensor performance. The reconfiguration of the network during initial set-up to accommodate deviations from idealized individual sensor detection zones improves the effectiveness of the sensor network in detecting activities at a detection perimeter and can provide the desired sensor coverage of an area while minimizing unintentional gaps in coverage.
Whole-cell luminescence biosensor-based lab-on-chip integrated system for water toxicity analysis
NASA Astrophysics Data System (ADS)
Rabner, Arthur; Belkin, Shimshon; Rozen, Rachel; Shacham, Yosi
2006-01-01
A novel water chemical toxin sensor has been successfully developed and evaluated as a working portable laboratory prototype. This sensor relies on a disposable plastic biochip prepared with a 4x4 micro-laboratory (μLab) chambers array of Escherichia coli reporter cells and micro-fluidic channels for liquids translocation. Each bacterial strain has been genetically modified into a bioluminescent reporter that responds to a pre-determined class of chemical agents. When challenged with a water sample containing a toxic chemical, the sensor responds with an increased bioluminescent signal from the biochip that is monitored over time. The signal is received by a motorized photomultiplier-based analyzer and interpreted by signal processing software. We have performed several levels of analysis: (i) the change in the bioluminescent signal from the sensor bacteria serves as a rapid indication for the presence of toxic chemicals in the water sample; (ii) the intensity of the change indicates the toxin concentration level; and (iii) the pattern of the responses for the different members of the bacterial panel on the biochip characterizes the biological origin of the toxin. The analyzer contains housing mechanics, electro-optics for signal acquisition, motorized readout calibration accessories, hydro-pneumatics modules for water sample translocation into biochip micro laboratories, electronics for overall control and communication with the host computer. This prototype has a demonstrated sensitivity for broad classes of water-borne toxic chemicals including naladixic acid (a model genotoxic agent), botulinum and acetylcholine esterase inhibitors. This work has initiated an investigation of a novel handheld field-deployable Water Toxicity Analysis (WTA) device.
Influence of Isoinertial-Pneumatic Mixed Resistances on Force-Velocity Relationship.
Avrillon, Simon; Jidovtseff, Boris; Hug, François; Guilhem, Gaël
2017-03-01
Muscle strengthening is commonly based on the use of isoinertial loading, whereas variable resistances such as pneumatic loading may be implemented to optimize training stimulus. The purpose of the current study was to determine the effect of the ratio between pneumatic and isoinertial resistance on the force-velocity relationship during ballistic movements. A total of 15 participants performed 2 concentric repetitions of ballistic bench-press movements with intention to throw the bar at 30%, 45%, 60%, 75%, and 90% of the maximal concentric repetition with 5 resistance ratios including 100%, 75%, 50%, 25%, or 0% of pneumatic resistance, the additional load being isoinertial. Force-, velocity-, and power-time patterns were assessed and averaged over the concentric phase to determine the force-velocity and power-velocity relationships for each resistance ratio. Each 25% increase in the pneumatic part in the resistance ratio elicited higher movement velocity (+0.11 ± 0.03 m/s from 0% to 80% of the concentric phase) associated with lower force levels (-43.6 ± 15.2 N). Increased isoinertial part in the resistance ratio resulted in higher velocity toward the end of the movement (+0.23 ± 0.01 m/s from 90% to 100%). The findings show that the resistance ratio could be modulated to develop the acceleration phase and force toward the end of the concentric phase (pneumatic-oriented resistance). Inversely, isoinertial-oriented resistance should be used to develop maximal force and maximal power. Resistance modality could, therefore, be considered an innovative variable to modulate the training stimulus according to athletic purposes.
Kearney, Sinéad M.; Kilcawley, Niamh A.; Early, Philip L.; Glynn, Macdara T.; Ducrée, Jens
2016-01-01
Here we present retrieval of Peripheral Blood Mononuclear Cells by density-gradient medium based centrifugation for subsequent analysis of the leukocytes on an integrated microfluidic “Lab-on-a-Disc” cartridge. Isolation of white blood cells constitutes a critical sample preparation step for many bioassays. Centrifugo-pneumatic siphon valves are particularly suited for blood processing as they function without need of surface treatment and are ‘low-pass’, i.e., holding at high centrifugation speeds and opening upon reduction of the spin rate. Both ‘hydrostatically’ and ‘hydrodynamically’ triggered centrifugo-pneumatic siphon valving schemes are presented. Firstly, the geometry of the pneumatic chamber of hydrostatically primed centrifugo-pneumatic siphon valves is optimised to enable smooth and uniform layering of blood on top of the density-gradient medium; this feature proves to be key for efficient Peripheral Blood Mononuclear Cell extraction. A theoretical analysis of hydrostatically primed valves is also presented which determines the optimum priming pressure for the individual valves. Next, ‘dual siphon’ configurations for both hydrostatically and hydrodynamically primed centrifugo-pneumatic siphon valves are introduced; here plasma and Peripheral Blood Mononuclear Cells are extracted through a distinct siphon valve. This work represents a first step towards enabling on disc multi-parameter analysis. Finally, the efficiency of Peripheral Blood Mononuclear Cells extraction in these structures is characterised using a simplified design. A microfluidic mechanism, which we termed phase switching, is identified which affects the efficiency of Peripheral Blood Mononuclear Cell extraction. PMID:27167376
Pneumatic pressure wave generator provides economical, simple testing of pressure transducers
NASA Technical Reports Server (NTRS)
Gaal, A. E.; Weldon, T. P.
1967-01-01
Testing device utilizes the change in pressure about a bias or reference pressure level produced by displacement of a center-driven piston in a closed cylinder. Closely controlled pneumatic pressure waves allow testing under dynamic conditions.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-10-31
... within Site 8 of FTZ 177. The facility is used for the manufacturing, testing, warehousing, packaging...: pneumatic tires, tubes, rolled rim rings, semi-pneumatic tires, herring-bone tires, welding wires and bolts...
Rolling resistance forces in pneumatic tires
DOT National Transportation Integrated Search
1976-01-31
An analysis is presented for the influence of test drum curvature on stress levels and resulting rolling resistance forces in pneumatic tires. The influence of test method on the measurement of rolling loss is also considered, and expressions are der...
Dualchannel Fuel Control Program.
1981-08-01
Generator 1 S Fluidic Speed Sensor and Power Turbine Wheels T = 0.1 s (speed) Recuperator 15 to 19 s Fluidic Temperature Sensor (temperature) T = 0.7 s...tradeoff between the highest sensitivity obtainable (as small a gap as possi- ble) and the noise or output variations due to disc runout . In
23. CORE WORKER OPERATING A COREBLOWER THAT PNEUMATICALLY FILLED CORE ...
23. CORE WORKER OPERATING A CORE-BLOWER THAT PNEUMATICALLY FILLED CORE BOXES WITH RESIGN IMPREGNATED SAND AND CREATED A CORE THAT THEN REQUIRED BAKING, CA. 1950. - Stockham Pipe & Fittings Company, 4000 Tenth Avenue North, Birmingham, Jefferson County, AL
Makarov, I Iu; Raĭzberg, S A
2012-01-01
The data available from the forensic medical practice do not allow the comprehensive, objective, and reliable assessment of injuries to the human body and damages to the clothes inflicted by the shots from a 9 millimeter (.357) or higher-caliber pneumatic rifle equipped with the pre-charge pneumatic system. The use of bullets of specific structure and configuration for such weapons accounts for their marked influence on the morphological features and the extent of the resulting wounds. These peculiarities provide a basis for the objective differentiation between their injurious effects.
Analysis of fine coal pneumatic systems
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mathur, M.P.; Rohatgi, N.D.; Klinzing, G.E.
1987-01-01
Many fossil fuel energy processes depend on the movement of solids by pneumatic transport. Despite the considerable amount of work reported in the literature on pneumatic transport, the design of new industrial systems for new products continues to rely to a great extent on empiricism. A pilot-scale test facility has been constructed at Pittsburgh Energy Technology Center (PETC) and is equipped with modern sophisticated measuring techniques (such as Pressure Transducers, Auburn Monitors, Micro Motion Mass flowmeters) and an automatic computer-controlled data acquisition system to study the effects of particle pneumatic transport. Pittsburgh Seam and Montana rosebud coals of varying sizemore » consist and moisture content were tested in the atmospheric and pressurized coal flow test loops (AP/CFTL and HP/CFTL) at PETC. The system parameters included conveying gas velocity, injector tank pressure, screw conveyor speed, pipe radius, and pipe bends. In the following report, results from the coal flow tests were presented and analyzed. Existing theories and correlations on two-phase flows were reviewed. Experimental data were compared with values calculated from empirically or theoretically derived equations available in the literature, and new correlations were proposed, when applicable, to give a better interpretation of the data and a better understanding of the various flow regimes involved in pneumatic transport. 55 refs., 56 figs., 6 tabs.« less
Design and Characterization of a Quasi-Passive Pneumatic Foot-Ankle Prosthesis.
Lee, Jeffrey D; Mooney, Luke M; Rouse, Elliott J
2017-07-01
The majority of commercially available passive prosthetic feet are not capable of providing joint mechanics that match that of the intact human ankle. Due to their cantilever design, their stiffness characteristics contrast with what has been observed in the biological ankle, namely, an increase in stiffness during the stance phase of walking. In this paper, we introduce the design and control of a pneumatic foot-ankle prosthesis that attempts to provide biomimetic mechanics. The prosthesis is comprised of a pneumatic cylinder in series with a fiberglass leaf spring, and a solenoid valve to control the flow of air between the two sides of the cylinder. The solenoid valve acts as a mechanical clutch, enabling resetting of the ankle's equilibrium position. By adjusting the pressure inside the cylinder, the prosthesis can be customized to provide a range of ankle mechanics. A mechanical testing machine is used to compare the torque-angle curve of the pneumatic prosthesis with a low-profile passive prosthetic foot. Finally, data are presented of one transtibial amputee walking with the prosthesis at 1.2 m/s. The testing shows that the pneumatic prosthesis is capable of providing an appropriate range of motion as well a maximum torque of 94 Nm, while returning approximately 11.5 J of energy.
EDITORIAL: Sensors and sensing systems
NASA Astrophysics Data System (ADS)
Dewhurst, Richard; Tian, Gui Yun
2008-02-01
Sensors are very important for measurement science and technology. They serve as a vital component in new measurement techniques and instrumentation systems. Key qualities of a good sensor system are high resolution, high reliability, low cost, appropriate output for a given input (good sensitivity), rapid response time, small random error in results, and small systematic error. Linearity is also useful, but with the advent of lookup tables and software, it is not as important as it used to be. In the last several years, considerable effort around the world has been devoted to a wide range of sensors from nanoscale sensors to sensor networks. Collectively, these vast and multidisciplinary efforts are developing important technological roadmaps to futuristic sensors with new modalities, significantly enhanced effectiveness and integrated functionality (data processing, computation, decision making and communications). When properly organized, they will have important relevance to life science and security applications, e.g. the sensing and monitoring of chemical, biological, radiological and explosive threats. A special feature in this issue takes a snapshot of some recent developments that were first presented at an international conference, the 2007 IEEE International Conference on Networking, Sensing and Control (ICNSC). The conference discussed recent developments, from which a few papers have since been brought together in this special feature. Gas sensing for environmental monitoring remains a topical subject, and two papers deal with this issue. One is concerned with the exploitation of nanostructured Au-doped cobalt oxyhydroxide-based carbon monoxide sensors for fire detection at its earlier stages (Zhuiykov and Dowling), whilst another examines the role of oxygen in high temperature hydrogen sulfide detection using MISiC sensors (Weng et al). Again for environmental monitoring, another paper deals with accurate sound source localization in a reverberant environment using multiple acoustic sensors (Atmoko et al). Not only is gaseous monitoring important, there are particular difficulties when it comes to the continuous monitoring of solids by non-destructive evaluation techniques. Examples of potential solutions for specialist applications are sensors for the detection and measurement of thin dielectric layers using reflection of frequency-scanned millimetre electromagnetic waves (Bowring et al), and an electrostatic sensor for velocity measurements of pneumatically conveyed solid particles (Xu et al). For potential medical applications, position measurement of internal organs is an on-going challenge. Tracking of internal organ motion with a six degree-of-freedom MEMS sensor is discussed by Bandala and Joyce. We hope that these papers provide an insight into exciting developments that continue to take place in the field of sensors and control.
Development of Overflow-Prevention Valve with Trigger Mechanism.
NASA Astrophysics Data System (ADS)
Ishino, Yuji; Mizuno, Takeshi; Takasaki, Masaya
2016-09-01
A new overflow-prevention valve for combustible fluid is developed which uses a trigger mechanism. Loading arms for combustible fluid are used for transferring oil from a tanker to tanks and vice versa. The loading arm has a valve for preventing overflow. Overflow- prevention valves cannot use any electric component to avoid combustion. Therefore, the valve must be constructed only by mechanical parts. The conventional overflow-prevention valve uses fluid and pneumatic forces. It consists of a sensor probe, a cylinder, a main valve for shutting off the fluid and a locking mechanism for holding an open state of the main valve. The proposed overflow-prevention valve uses the pressure due to the height difference between the fluid level of the tank and the sensor probe. However, the force of the cylinder produced by the pressure is too small to release the locking mechanism. Therefore, a trigger mechanism is introduced between the cylinder and the locking mechanism. The trigger mechanism produces sufficient force to release the locking mechanism and close the main valve when the height of fluid exceeds a threshold value. A trigger mechanism is designed and fabricated. The operation necessary for closing the main valve is conformed experimentally.
NASA Astrophysics Data System (ADS)
Du, Zhiyuan; Hu, Bin; Cyril, Planchon; Liu, Juan; Wang, Yongtian
2017-10-01
Local surface plasmonic resonance (LSPR) produced by metallic nano-structures is often sensitive to the refractive index of the surrounding media and can be applied for sensing. However, it often suffers from large line width caused by large plasmonic radiative damping, especially in the infrared (IR) frequencies, which reduces the sensitivity. Here we propose a hybrid structure consists of a graphene stripe and a gold gap-ring at short-IR frequencies (1-3 µm). Due to the low loss and high plasmonic confinement of graphene, LSPR line width of 6 nm is obtained. In addition, due to the strong coupling of the gold gap-ring with graphene stripe, the intensity of graphene LSPR is enhanced by 100 times. Simulation results show that the sensitivity of the sensor is ~1000 nm/RIU (refractive index unit) and the figure of merit (FoM) can reach up to 383.
Optical fiber F-P magnetic field sensor based on magnetostrictive effect of magnetic fluid
NASA Astrophysics Data System (ADS)
Shi, Fuquan; Luo, Yan; Che, Jiajia; Ren, Zhijun; peng, Baojin
2018-07-01
magnetic field sensor of air-gap Fabry-Perot fiber interferometersis proposed based on magnetostrictive effect. The sensor is consisted of single-model fiber (SMF), air-gap, no-core fiber (NCF) and magnetic fluid. Those are sealed in the capillary, SMF and NCF are connect with air chamber and magnetic fluid column. With the presence of an external magnetic field, air chamber cavity length changes because of the magneto-volume variation of magnetic fluids. This situation causes a change in the optical path difference. Detection of the drift of interference spectrum leads to the detection of the change in magnetic field. When the magnetic field is parallel to the direction in which the capillary is placed, the sensitivity is 0.2347 nm/mT; when the magnetic fluid is perpendicular to the direction in which the capillary is placed, the sensitivity is 0.325 nm/http://mT.%20In.
Selection of optimal sensors for predicting performance of polymer electrolyte membrane fuel cell
NASA Astrophysics Data System (ADS)
Mao, Lei; Jackson, Lisa
2016-10-01
In this paper, sensor selection algorithms are investigated based on a sensitivity analysis, and the capability of optimal sensors in predicting PEM fuel cell performance is also studied using test data. The fuel cell model is developed for generating the sensitivity matrix relating sensor measurements and fuel cell health parameters. From the sensitivity matrix, two sensor selection approaches, including the largest gap method, and exhaustive brute force searching technique, are applied to find the optimal sensors providing reliable predictions. Based on the results, a sensor selection approach considering both sensor sensitivity and noise resistance is proposed to find the optimal sensor set with minimum size. Furthermore, the performance of the optimal sensor set is studied to predict fuel cell performance using test data from a PEM fuel cell system. Results demonstrate that with optimal sensors, the performance of PEM fuel cell can be predicted with good quality.
DOT National Transportation Integrated Search
2016-12-01
The following progress report describes the laboratory activities completed for the development of the experimental field program designed to evaluate sediment amendment using the Pneumatic Flow Tube Mixing Apparatus (PFTM) in NY/NJ Harbor. These act...
46 CFR 76.05-1 - Fire detecting systems.
Code of Federal Regulations, 2010 CFR
2010-10-01
... fitted with an automatic sprinkling system, except in relatively incombustible spaces. 2 Sprinkler heads....1 Offices, lockers, and isolated storerooms Electric, pneumatic, or automatic sprinkling1 Do.1 Public spaces None required with 20-minute patrol. Electric, pneumatic, or automatic sprinkling with 1...
46 CFR 76.05-1 - Fire detecting systems.
Code of Federal Regulations, 2011 CFR
2011-10-01
... fitted with an automatic sprinkling system, except in relatively incombustible spaces. 2 Sprinkler heads....1 Offices, lockers, and isolated storerooms Electric, pneumatic, or automatic sprinkling1 Do.1 Public spaces None required with 20-minute patrol. Electric, pneumatic, or automatic sprinkling with 1...
NASA Astrophysics Data System (ADS)
Kumarasubramanian, R.; Xavier, Goldwin; Nishanthi, W. Mary; Rajasekar, R.
2017-05-01
Considering the fuel crises today many work and research were conducted to reduce the fuel consumption of the internal combustion engine. The fuel consumption of an internal combustion engine can be relatively reduced by use of the electromagnetic clutch water pump and pneumatic compressor. Normally in an engine, the water pump is driven by the crankshaft, with an aid of belt, for the circulation of the water for the cooling process. The circulation of coolant is resisted by the thermostat valve, while the temperature inside the coolant jacket of the engine is below 375K the thermostat is closed only above 375K it tends to open. But water pump run continuously even when thermostat is closed. In pneumatic braking system, pneumatic or air compressor purpose is to compress the air and stored into the storage tank for the brake operation. When the air pressure of the storage tanks gets increases above its storage capacity pressure is regulated by governor, by passing them to atmosphere. Such unnecessary work of this water pump and air compressor can be minimized by use of the electromagnetic clutch water pump and air compressor. The European Driving Cycle is used to evaluate the performance of this water pump and air compressor when used in an engine. The result shows that the fuel economy of the engine while using electromagnetic water pump and pneumatic compressor were improved by 8.0% compared with conventional types which already exist. The application of these electromagnetic water pump and pneumatic compressor are expected to contribute for the improvement of engine performance because of their effect in reduction of the rate of fuel consumption.
Spatial Aspects of Multi-Sensor Data Fusion: Aerosol Optical Thickness
NASA Technical Reports Server (NTRS)
Leptoukh, Gregory; Zubko, V.; Gopalan, A.
2007-01-01
The Goddard Earth Sciences Data and Information Services Center (GES DISC) investigated the applicability and limitations of combining multi-sensor data through data fusion, to increase the usefulness of the multitude of NASA remote sensing data sets, and as part of a larger effort to integrate this capability in the GES-DISC Interactive Online Visualization and Analysis Infrastructure (Giovanni). This initial study focused on merging daily mean Aerosol Optical Thickness (AOT), as measured by the Moderate Resolution Imaging Spectroradiometer (MODIS) onboard the Terra and Aqua satellites, to increase spatial coverage and produce complete fields to facilitate comparison with models and station data. The fusion algorithm used the maximum likelihood technique to merge the pixel values where available. The algorithm was applied to two regional AOT subsets (with mostly regular and irregular gaps, respectively) and a set of AOT fields that differed only in the size and location of artificially created gaps. The Cumulative Semivariogram (CSV) was found to be sensitive to the spatial distribution of gap areas and, thus, useful for assessing the sensitivity of the fused data to spatial gaps.
Virtual environment application with partial gravity simulation
NASA Technical Reports Server (NTRS)
Ray, David M.; Vanchau, Michael N.
1994-01-01
To support manned missions to the surface of Mars and missions requiring manipulation of payloads and locomotion in space, a training facility is required to simulate the conditions of both partial and microgravity. A partial gravity simulator (Pogo) which uses pneumatic suspension is being studied for use in virtual reality training. Pogo maintains a constant partial gravity simulation with a variation of simulated body force between 2.2 and 10 percent, depending on the type of locomotion inputs. this paper is based on the concept and application of a virtual environment system with Pogo including a head-mounted display and glove. The reality engine consists of a high end SGI workstation and PC's which drive Pogo's sensors and data acquisition hardware used for tracking and control. The tracking system is a hybrid of magnetic and optical trackers integrated for this application.
Ramifications of a potential gap in passive microwave data for the long-term sea ice climate record
NASA Astrophysics Data System (ADS)
Meier, W.; Stewart, J. S.
2017-12-01
The time series of sea ice concentration and extent from passive microwave sensors is one of the longest satellite-derived climate records and the significant decline in Arctic sea ice extent is one of the most iconic indicators of climate change. However, this continuous and consistent record is under threat due to the looming gap in passive microwave sensor coverage. The record started in late 1978 with the launch of the Scanning Multichannel Microwave Radiometer (SMMR) and has continued with a series of Special Sensor Microwave Imager (SSMI) and Special Sensor Microwave Imager and Sounder (SSMIS) instruments on U.S. Defense Meteorological Satellite Program (DMSP) satellites. The data from the different sensors are intercalibrated at the algorithm level by adjusting algorithm coefficients so that the output sea ice data is as consistent as possible between the older and the newer sensor. A key aspect in constructing the time series is to have at least two sensors operating simultaneously so that data from the older and newer sensor can be obtained from the same locations. However, with recent losses of the DMSP F19 and F20, the remaining SSMIS sensors are all well beyond their planned mission lifetime. This means that risk of failure is not small and is increasing with each day of operation. The newest passive microwave sensor, the JAXA Advanced Microwave Scanning Radiometer-2 (AMSR2), is a potential contributor to the time series (though it too is now beyond it's planned 5-year mission lifetime). However, AMSR2's larger antenna and higher spatial resolution presents a challenge in integrating its data with the rest of the sea ice record because the ice edge is quite sensitive to the sensor resolution, which substantially affects the total sea ice extent and area estimates. This will need to be adjusted for if AMSR2 is used to continue the time series. Here we will discuss efforts at NSIDC to integrate AMSR2 estimates into the sea ice climate record if needed. We will also discuss potential contingency plans, such as using operational sea ice charts, to fill any gaps. This would allow the record to continue, but the consistency of the time series will be degraded because the ice charts use human analysis and differing sources, amounts and quality of input data, which makes them sub-optimal for long-term climate records.
Landsat sensor performance: history and current status
Markham, B.L.; Storey, James C.; Williams, Darrel L.; Irons, J.R.
2004-01-01
The current Thematic Mapper (TM) class of Landsat sensors began with Landsat-4, which was launched in 1982. This series continued with the nearly identical sensor on Landsat-5, launched in 1984. The final sensor in the series was the Landsat-7 Enhanced Thematic Mapper Plus (ETM+), which was carried into orbit in 1999. Varying degrees of effort have been devoted to the characterization of these instruments and data over the past 22 years. Extensive short-lived efforts early in the history, very limited efforts in the middle years, and now a systematic program for continuing characterization of all three systems are apparent. Currently, both the Landsat-5 TM and the Landsat-7 ETM+ are operational and providing data. Despite 20+ years of operation, the TM on Landsat-5 is fully functional, although downlinks for the data are limited. Landsat-7 ETM+ experienced a failure of its Scan Line Corrector mechanism in May 2003. Although there are gaps in the data coverage, the data remain of equivalent quality to prefailure data. Data products have been developed to fill these gaps using other ETM+ scenes.
NASA Astrophysics Data System (ADS)
Wang, Anbo; Miller, Mark S.; Plante, Angela J.; Gunther, Michael F.; Murphy, Kent A.; Claus, Richard O.
1996-05-01
A self-referencing technique compensating for fiber losses and source fluctuations in reflective air-gap intensity-based optical fiber sensors is described. A dielectric multilayer short-wave-pass filter is fabricated onto or attached to the output end face of the lead-in-lead-out multimode fiber. The incoming broadband light from a white light or a light-emitting diode is partially reflected at the filter. The transmitted light through the filter projects onto a mirror. The light returning from the reflecting mirror is recoupled into the lead-in-lead-out fiber. These two reflections from the filter and the reflecting mirror are spectrally separated at the detector end. The power ratio of these two reflections is insensitive to source fluctuations and fiber-bending loss. However, because the second optical signal depends on the air-gap separation between the end face of the lead-in-lead-out fiber and the reflecting mirror, the ratio provides the information on the air-gap length. A resolution of 0.13 mu m has been obtained over a microdisplacement measurement range of 0-254 mu m. The sensor is shown to be insensitive to both fiber-bending losses and variations in source power. Based on this approach, a fiber-strain sensor was fabricated with a multilayer interference filter directly fabricated on the end face of the fiber. A resolution of 13.4 microstrain was obtained over a measurement range of 0-20,000 microstrain with a gauge length of 10 mm. The split-spectrum method is also incorporated into a diaphragm displacement-based pressure sensor with a demonstrated resolution of 450 Pa over a measurement range of 0-0.8 MPa.
Fiber optic temperature sensor
NASA Technical Reports Server (NTRS)
Sawatari, Takeo (Inventor); Gaubis, Philip A. (Inventor)
2000-01-01
A fiber optic temperature sensor uses a light source which transmits light through an optical fiber to a sensor head at the opposite end of the optical fiber from the light source. The sensor head has a housing coupled to the end of the optical fiber. A metallic reflective surface is coupled to the housing adjacent the end of the optical fiber to form a gap having a predetermined length between the reflective surface and the optical fiber. A detection system is also coupled to the optical fiber which determines the temperature at the sensor head from an interference pattern of light which is reflected from the reflective surface.
Fiber optic temperature sensor
NASA Technical Reports Server (NTRS)
Sawatari, Takeo (Inventor); Gaubis, Philip A. (Inventor); Mattes, Brenton L. (Inventor); Charnetski, Clark J. (Inventor)
1999-01-01
A fiber optic temperature sensor uses a light source which transmits light through an optical fiber to a sensor head at the opposite end of the optical fiber from the light source. The sensor head has a housing coupled to the end of the optical fiber. A metallic reflective surface is coupled to the housing adjacent the end of the optical fiber to form a gap having a predetermined length between the reflective surface and the optical fiber. A detection system is also coupled to the optical fiber which determines the temperature at the sensor head from an interference pattern of light which is reflected from the reflective surface.
LPT. Low power test (TAN641) interior. Heating and ventilating pneumatic ...
LPT. Low power test (TAN-641) interior. Heating and ventilating pneumatic and electrical control panel. Contract nearly complete. Photographer: Jack L. Anderson. Date: December 19, 1957. INEEL negative no. 57-6198 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID
Compaction of asphaltic concrete pavement with high intensity pneumatic roller : part I.
DOT National Transportation Integrated Search
1963-07-01
The purpose of this investigation was to: : 1) Determine the magnitude of the compactive effort and the umber of passes required in the field to obtain optimum density using a high intensity pneumatic roller. : 2) Effect a correlation between the fie...
21 CFR 870.2780 - Hydraulic, pneumatic, or photoelectric plethysmographs.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Hydraulic, pneumatic, or photoelectric plethysmographs. 870.2780 Section 870.2780 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Monitoring Devices...
A Rare Cause of Headache: Pneumatized Nasal Septum Osteoma.
Erdoğan, Osman; Ismi, Onur; Tezer, Mesut Sabri
2017-11-01
Paranasal sinus osteomas are among the rare causes of headache and they are most commonly seen in the frontal and ethmoid sinuses. In this report, we presented the first case of pneumatized nasal septum osteoma causing headache, successfully treated with endoscopic transnasal approach.
DOT National Transportation Integrated Search
2013-07-01
This study explored possibilities for using existing transportation infrastructure for the cost-effective : installation of pneumatic waste-collection technology in Manhattan. If shown to be economically and : operationally feasible, reducing the num...
The U.S. Environmental Protection Agency (EPA), in cooperation with Accutech Remedial Systems (ARS) and the New Jersey Institute of Technology (NJIT) performed a field demonstration of Pneumatic Fracturing Extraction (PFE) for the removal of chlorinated volatile organics (VOCS) f...
46 CFR 162.161-4 - Construction.
Code of Federal Regulations, 2014 CFR
2014-10-01
...: SPECIFICATIONS AND APPROVAL ENGINEERING EQUIPMENT Fixed Clean Agent Fire Extinguishing Systems § 162.161-4... mechanical or pneumatic means. (d) Automatically actuated systems must be released by pneumatic or fusible... actuation and have a remote backup manual mechanical actuator. (f) Each container charged with nitrogen must...
46 CFR 162.161-4 - Construction.
Code of Federal Regulations, 2012 CFR
2012-10-01
...: SPECIFICATIONS AND APPROVAL ENGINEERING EQUIPMENT Fixed Clean Agent Fire Extinguishing Systems § 162.161-4... mechanical or pneumatic means. (d) Automatically actuated systems must be released by pneumatic or fusible... actuation and have a remote backup manual mechanical actuator. (f) Each container charged with nitrogen must...
46 CFR 162.161-4 - Construction.
Code of Federal Regulations, 2013 CFR
2013-10-01
...: SPECIFICATIONS AND APPROVAL ENGINEERING EQUIPMENT Fixed Clean Agent Fire Extinguishing Systems § 162.161-4... mechanical or pneumatic means. (d) Automatically actuated systems must be released by pneumatic or fusible... actuation and have a remote backup manual mechanical actuator. (f) Each container charged with nitrogen must...
21 CFR 870.2780 - Hydraulic, pneumatic, or photoelectric plethysmographs.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Hydraulic, pneumatic, or photoelectric plethysmographs. 870.2780 Section 870.2780 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Monitoring Devices...
Evacuation of coal from hoppers/silos with low pressure pneumatic blasting systems
NASA Technical Reports Server (NTRS)
Fischer, J. S.
1977-01-01
The need for an efficient, economical, effective and quiet device for moving coal and other difficult bulk solids was recognized. Thus came the advent of the low pressure pneumatic blasting system - a very efficient means of using a small amount of plant air (up to 125 PSI) to eliminate the most troublesome material hang-ups in storage containers. This simple device has one moving part and uses approximately 3% of the air consumed by a pneumatic vibrator on the same job. The principle of operation is very simple: air stored in the unit's reservoir is expelled directly into the material via a patented quick release valve. The number, size, and placement of the blaster units on the storage vessel is determined by a series of tests to ascertain flowability of the problem material. These tests in conjunction with the hopper or silo configuration determine specification of a low pressure pneumatic blasting system. This concept has often proven effective in solving flow problems when all other means have failed.
A Model-Based Prognostics Approach Applied to Pneumatic Valves
NASA Technical Reports Server (NTRS)
Daigle, Matthew J.; Goebel, Kai
2011-01-01
Within the area of systems health management, the task of prognostics centers on predicting when components will fail. Model-based prognostics exploits domain knowledge of the system, its components, and how they fail by casting the underlying physical phenomena in a physics-based model that is derived from first principles. Uncertainty cannot be avoided in prediction, therefore, algorithms are employed that help in managing these uncertainties. The particle filtering algorithm has become a popular choice for model-based prognostics due to its wide applicability, ease of implementation, and support for uncertainty management. We develop a general model-based prognostics methodology within a robust probabilistic framework using particle filters. As a case study, we consider a pneumatic valve from the Space Shuttle cryogenic refueling system. We develop a detailed physics-based model of the pneumatic valve, and perform comprehensive simulation experiments to illustrate our prognostics approach and evaluate its effectiveness and robustness. The approach is demonstrated using historical pneumatic valve data from the refueling system.
Giannaccini, Maria Elena; Xiang, Chaoqun; Atyabi, Adham; Theodoridis, Theo; Nefti-Meziani, Samia; Davis, Steve
2018-02-01
Soft robot arms possess unique capabilities when it comes to adaptability, flexibility, and dexterity. In addition, soft systems that are pneumatically actuated can claim high power-to-weight ratio. One of the main drawbacks of pneumatically actuated soft arms is that their stiffness cannot be varied independently from their end-effector position in space. The novel robot arm physical design presented in this article successfully decouples its end-effector positioning from its stiffness. An experimental characterization of this ability is coupled with a mathematical analysis. The arm combines the light weight, high payload to weight ratio and robustness of pneumatic actuation with the adaptability and versatility of variable stiffness. Light weight is a vital component of the inherent safety approach to physical human-robot interaction. To characterize the arm, a neural network analysis of the curvature of the arm for different input pressures is performed. The curvature-pressure relationship is also characterized experimentally.
GU, SI-PING; YOU, ZHI-YUAN; HUANG, YUNTENG; LU, YI-JIN; HE, CAOHUI; CAI, XIAO-DONG; ZHOU, XIAO-MING
2013-01-01
The aim of this study was to investigate the effectiveness of minimally invasive percutaneous cystostomy with ureteroscopic pneumatic lithotripsy for treating calculus in bladder diverticula. Percutaneous cystostomy with ureteroscopic pneumatic lithotripsy was performed on six elderly male patients with calculi in bladder diverticula, who could not be treated with transurethral ureteroscopic lithotripsy. The stones were successfully removed from all patients, with no complications such as bladder perforation, rupture, urethritis or cystitis. The surgery time was 15–60 min, with an average time of 32 min. Postoperative ultrasound or X-ray examination showed no stone residues and the bladder stoma healed well. No recurrent stones were detected in the follow-up of 3–24 months (average, 16 months). Minimally invasive percutaneous cystostomy with ureteroscopic pneumatic lithotripsy is a safe, efficient and easy treatment for calculus in bladder diverticula. This method provides a new clinical approach for lithotripsy and we suggest that it is worthy of wider use. PMID:23837044
OMS engine shutoff valve and actuation system design and evaluation. [for space shuttles
NASA Technical Reports Server (NTRS)
Wichmann, H.
1974-01-01
Shutoff valve and actuation system concepts that are most suitable for the Orbital Maneuvering Systems engine application were determined. Emphasis was placed on the ten year and 100 mission life requirement, propellant and propellant residue compatibility and weight. It was found that poppet or ball valves utilizing electric or electropneumatic actuation were most applicable. Preliminary design layouts of a number of valve and actuation concepts were prepared and analyzed to make the optimum concept selection. Pneumatic actuation systems were required to feature their own pneumatic supply so that for the quad redundant valve, it was necessary to include two pneumatic supply systems, one for each of the series legs of the quad redundant package. The requirement for the pneumatic package placed heavy reliability, weight, and maintenance penalties upon electropneumatic actuation systems. The two valve and actuation systems concepts selected featured electric torque motor operation and a poppet as well as a ball valve concept with a retractable seal.
Xiang, Chaoqun; Atyabi, Adham; Theodoridis, Theo; Nefti-Meziani, Samia; Davis, Steve
2018-01-01
Abstract Soft robot arms possess unique capabilities when it comes to adaptability, flexibility, and dexterity. In addition, soft systems that are pneumatically actuated can claim high power-to-weight ratio. One of the main drawbacks of pneumatically actuated soft arms is that their stiffness cannot be varied independently from their end-effector position in space. The novel robot arm physical design presented in this article successfully decouples its end-effector positioning from its stiffness. An experimental characterization of this ability is coupled with a mathematical analysis. The arm combines the light weight, high payload to weight ratio and robustness of pneumatic actuation with the adaptability and versatility of variable stiffness. Light weight is a vital component of the inherent safety approach to physical human-robot interaction. To characterize the arm, a neural network analysis of the curvature of the arm for different input pressures is performed. The curvature-pressure relationship is also characterized experimentally. PMID:29412080
Lee, Eunha; Benayad, Anass; Shin, Taeho; Lee, HyungIk; Ko, Dong-Su; Kim, Tae Sang; Son, Kyoung Seok; Ryu, Myungkwan; Jeon, Sanghun; Park, Gyeong-Su
2014-01-01
Interest in oxide semiconductors stems from benefits, primarily their ease of process, relatively high mobility (0.3–10 cm2/vs), and wide-bandgap. However, for practical future electronic devices, the channel mobility should be further increased over 50 cm2/vs and wide-bandgap is not suitable for photo/image sensor applications. The incorporation of nitrogen into ZnO semiconductor can be tailored to increase channel mobility, enhance the optical absorption for whole visible light and form uniform micro-structure, satisfying the desirable attributes essential for high performance transistor and visible light photo-sensors on large area platform. Here, we present electronic, optical and microstructural properties of ZnON, a composite of Zn3N2 and ZnO. Well-optimized ZnON material presents high mobility exceeding 100 cm2V−1s−1, the band-gap of 1.3 eV and nanocrystalline structure with multiphase. We found that mobility, microstructure, electronic structure, band-gap and trap properties of ZnON are varied with nitrogen concentration in ZnO. Accordingly, the performance of ZnON-based device can be adjustable to meet the requisite of both switch device and image-sensor potentials. These results demonstrate how device and material attributes of ZnON can be optimized for new device strategies in display technology and we expect the ZnON will be applicable to a wide range of imaging/display devices. PMID:24824778
Balachandran, Anoop T; Gandia, Kristine; Jacobs, Kevin A; Streiner, David L; Eltoukhy, Moataz; Signorile, Joseph F
2017-11-01
Power training has been shown to be more effective than conventional resistance training for improving physical function in older adults; however, most trials have used pneumatic machines during training. Considering that the general public typically has access to plate-loaded machines, the effectiveness and safety of power training using plate-loaded machines compared to pneumatic machines is an important consideration. The purpose of this investigation was to compare the effects of high-velocity training using pneumatic machines (Pn) versus standard plate-loaded machines (PL). Independently-living older adults, 60years or older were randomized into two groups: pneumatic machine (Pn, n=19) and plate-loaded machine (PL, n=17). After 12weeks of high-velocity training twice per week, groups were analyzed using an intention-to-treat approach. Primary outcomes were lower body power measured using a linear transducer and upper body power using medicine ball throw. Secondary outcomes included lower and upper body muscle muscle strength, the Physical Performance Battery (PPB), gallon jug test, the timed up-and-go test, and self-reported function using the Patient Reported Outcomes Measurement Information System (PROMIS) and an online video questionnaire. Outcome assessors were blinded to group membership. Lower body power significantly improved in both groups (Pn: 19%, PL: 31%), with no significant difference between the groups (Cohen's d=0.4, 95% CI (-1.1, 0.3)). Upper body power significantly improved only in the PL group, but showed no significant difference between the groups (Pn: 3%, PL: 6%). For balance, there was a significant difference between the groups favoring the Pn group (d=0.7, 95% CI (0.1, 1.4)); however, there were no statistically significant differences between groups for PPB, gallon jug transfer, muscle muscle strength, timed up-and-go or self-reported function. No serious adverse events were reported in either of the groups. Pneumatic and plate-loaded machines were effective in improving lower body power and physical function in older adults. The results suggest that power training can be safely and effectively performed by older adults using either pneumatic or plate-loaded machines. Copyright © 2017 Elsevier Inc. All rights reserved.
Evaluation of a pneumatic Martian soil sampler concept
NASA Technical Reports Server (NTRS)
Schaefer, John L.; Neathery, James K.; Stencel, John M.
1994-01-01
The pneumatic soil sampler concept was successfully demonstrated by penetrating a Martian simulant soil to a depth of 2 meters. Working gas pressure, composition, and pulsing were evaluated with the objective of minimizing gas usage. Also, the probe penetration force was investigated with the objective of minimizing probe weight. Gas and probe penetration force, while not yet optimized, are within the range which make the soil sampler concept feasible. While the tests described in this report did not answer all the questions and address all the variables associated with pneumatic soil sampling, valuable data experience and knowledge were gained which can be used to further develop the concept.
ERIC Educational Resources Information Center
Engelbrecht, Nancy; And Others
This unit on pneumatics, for use in postsecondary programs, is organized in eight sections. Each section consists of information sheets with line drawings and multiple-choice questions for each topic in the sections. Answers are provided at the back of the book. The following topics are covered: (1) introduction--pressure, principles of gases,…
Pneumatic Conveying of Seed Cotton: Minimum Velocity and Pressure Drop
USDA-ARS?s Scientific Manuscript database
Electricity is major cost for cotton gins, representing approximately 20% of the industry’s variable costs. Fans used for pneumatic conveying consume the majority of electricity at cotton gins. Development of control systems to reduce the air velocity used for conveying seed cotton could significant...
Pneumatic Conveying of Seed Cotton: Minimum Velocity and Pressure Drop
USDA-ARS?s Scientific Manuscript database
Electricity is a major cost for cotton gins, representing approximately 20% of variable costs. Fans used for pneumatic conveying consume the majority of electricity at cotton gins. Development of control systems to reduce the air velocity used for conveying seed cotton could significantly decrease e...
DOT National Transportation Integrated Search
2001-01-16
This report was prepared in order to document the findings of a one year environmental and hydrographic survey program conducted as part of the Air GuardTM Pneumatic Sediment Suspension System installation at IMTT in Bayonne. This system was installe...
This document summarizes and analyzes the results of a 4-wk evaluation of the Accutech Remedial Systems, Inc. (ARS) Pneumatic Fracturing Extraction™ (PFE™) process for increasing the removal of volatile organic contaminants from the vadose zone, particularly where the ground form...
Pneumatic vacuum tube message center, basement room 23, looking southeast ...
Pneumatic vacuum tube message center, basement room 23, looking southeast toward doorway and corridor. Note soundproof walls, pedestal flooring, and cable tray suspended from the ceiling - March Air Force Base, Strategic Air Command, Combat Operations Center, 5220 Riverside Drive, Moreno Valley, Riverside County, CA
Code of Federal Regulations, 2010 CFR
2010-10-01
..., DEPARTMENT OF TRANSPORTATION (CONTINUED) TIRE IDENTIFICATION AND RECORDKEEPING § 574.4 Applicability. This... retreaded tires, and new non-pneumatic tires and non-pneumatic tire assemblies for use on motor vehicles... does not apply to persons who retread tires solely for their own use. [36 FR 5422, Mar. 23, 1971, as...
Braided artificial muscles: modeling and experimental validation
NASA Astrophysics Data System (ADS)
Dragan, Liliana; Cioban, Horia
2009-01-01
The paper presents a few graphical modalities for constructing the double helical braid, which is the basis for the braided artificial pneumatic muscles, by using specialized software applications. This represents the first stage in achieving the method of finite element analysis of this type of linear pneumatic actuator.
Electropneumatic transducer automatically limits motor current
NASA Technical Reports Server (NTRS)
Lovitt, T. F.
1966-01-01
Pneumatic controller regulates the load on a centrifugal freon compressor in a water cooling system, thus limiting the current input to an electric motor driving it. An electromechanical transducer monitoring the motor input current sends out air signals which indicate changes in the current to the pneumatic controller.
60. Shock isolator at center, pneumatic control group panel at ...
60. Shock isolator at center, pneumatic control group panel at left, power distribution box at right, all at right of entrance to lcc. - Ellsworth Air Force Base, Delta Flight, Launch Control Facility, County Road CS23A, North of Exit 127, Interior, Jackson County, SD
Araújo, Ricardo; Mateus, Octávio
2015-01-01
The quadrate of reptiles and most other tetrapods plays an important morphofunctional role by allowing the articulation of the mandible with the cranium. In Theropoda, the morphology of the quadrate is particularly complex and varies importantly among different clades of non-avian theropods, therefore conferring a strong taxonomic potential. Inconsistencies in the notation and terminology used in discussions of the theropod quadrate anatomy have been noticed, including at least one instance when no less than eight different terms were given to the same structure. A standardized list of terms and notations for each quadrate anatomical entity is proposed here, with the goal of facilitating future descriptions of this important cranial bone. In addition, an overview of the literature on quadrate function and pneumaticity in non-avian theropods is presented, along with a discussion of the inferences that could be made from this research. Specifically, the quadrate of the large majority of non-avian theropods is akinetic but the diagonally oriented intercondylar sulcus of the mandibular articulation allowed both rami of the mandible to move laterally when opening the mouth in many of theropods. Pneumaticity of the quadrate is also present in most averostran clades and the pneumatic chamber—invaded by the quadrate diverticulum of the mandibular arch pneumatic system—was connected to one or several pneumatic foramina on the medial, lateral, posterior, anterior or ventral sides of the quadrate. PMID:26401455
The characteristic of gap FBG and its application
NASA Astrophysics Data System (ADS)
Yang, Yuanhong; Hu, Jun; Liu, Xuejing; Jin, Wei
2015-07-01
A gap fiber Bragg grating (g-FBG) is fabricated by cutting a uniform FBG in the middle to introduce a small air gap between the two sections. Numerical and experimental investigations show that the g-FBG has the characteristics of both a phase shifted FBG and a Fizeau interferometer. The influence of the air-gap shift longitudinally or transversely with respect to the fiber central axis and temperature to g-FBG's spectrums are investigated with numerical simulation and experiments, and the mathematic models are made. Based on g-FBG's different sensitivity to gap width and temperature, a micro-gap and temperature simultaneous measurement sensor was demonstrated. And a g-FBG based tunable fiber ring laser with a narrow line-width is demonstrated.
A miniature extrinsic fiber Fabry-Perot pressure sensor based on fiber etching
NASA Astrophysics Data System (ADS)
Ge, Yixian; Zhou, Junping; Wang, Tingting
2011-11-01
A miniature fiber optic pressure sensor based on Fabry-Perot interference fabricated on the tip of a single mode (SM) fiber is presented. The sensor measures only 125μm in diameter. A Fabry-Perot cavity and a thin silica diaphragm are fabricated by simple techniques involving only cleaving, wet chemical etching and fusion splicing. Interference pattern of the sensor is analyzed and issues in sensor design are discussed. The overall chemical reaction of the fiber wet etching is specifically represented. Pressure testing system is carried out. By tracing a peak point in the interference spectrum, the gap length of the sensor can be demodulated. Experimental results show the sensor has a good linearity. The sensor is made entirely of fused silica, whose structure has good stability, cabinet, simple for fabrication and low cost.
Study made of pneumatic high pressure piping materials /10,000 psi/
NASA Technical Reports Server (NTRS)
Loeb, M. B.; Smith, J. C.
1967-01-01
Evaluations of five types of steel for use in high pressure pneumatic piping systems include tests for impact strength, tensile and yield strengths, elongation and reduction in area, field weldability, and cost. One type, AISI 4615, was selected as most advantageous for extensive use in future flight vehicles.
Pneumatics. Student's Manual [and] Instructor's Guide.
ERIC Educational Resources Information Center
Notgrass, Troy
The student's manual in this two-part instructional kit is designed to help the following types of students learn introductory technical material related to pneumatics: (1) groups of trade and industrial students with a variety of vocational objectives and (2) homogeneous groups in which the learning levels of individual students vary…
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 2 2013-10-01 2013-10-01 false Tests. 58.20-25 Section 58.20-25 Shipping COAST GUARD... SYSTEMS Refrigeration Machinery § 58.20-25 Tests. (a) All pressure vessels, compressors, piping, and..., hydrostatically or pneumatically. (b) No pneumatic tests in refrigeration systems aboard ships shall be made at...
Code of Federal Regulations, 2014 CFR
2014-10-01
... 46 Shipping 2 2014-10-01 2014-10-01 false Tests. 58.20-25 Section 58.20-25 Shipping COAST GUARD... SYSTEMS Refrigeration Machinery § 58.20-25 Tests. (a) All pressure vessels, compressors, piping, and..., hydrostatically or pneumatically. (b) No pneumatic tests in refrigeration systems aboard ships shall be made at...
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 2 2012-10-01 2012-10-01 false Tests. 58.20-25 Section 58.20-25 Shipping COAST GUARD... SYSTEMS Refrigeration Machinery § 58.20-25 Tests. (a) All pressure vessels, compressors, piping, and..., hydrostatically or pneumatically. (b) No pneumatic tests in refrigeration systems aboard ships shall be made at...
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 2 2011-10-01 2011-10-01 false Tests. 58.20-25 Section 58.20-25 Shipping COAST GUARD... SYSTEMS Refrigeration Machinery § 58.20-25 Tests. (a) All pressure vessels, compressors, piping, and..., hydrostatically or pneumatically. (b) No pneumatic tests in refrigeration systems aboard ships shall be made at...
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 2 2010-10-01 2010-10-01 false Tests. 58.20-25 Section 58.20-25 Shipping COAST GUARD... SYSTEMS Refrigeration Machinery § 58.20-25 Tests. (a) All pressure vessels, compressors, piping, and..., hydrostatically or pneumatically. (b) No pneumatic tests in refrigeration systems aboard ships shall be made at...
Pneumatic binary encoder replaces multiple solenoid system
NASA Technical Reports Server (NTRS)
1966-01-01
Pneumatic binary encoder replaces solenoid system in the pilot stage of a digital actuator. The encoder operates in flip-flop manner to valve gas at either high or low pressures. By rotating the disk in a pinion-to-encoding gear ratio, six to eight adder circuits may be operated from single encoder.
2003-12-01
potential problem is decreasing the permeability by pneumatic or hydraulic fracturing . Pneumatic fracturing (PF) uses the injection of pressurized air...to increase the biodegradation of the contaminants. Hydraulic fracturing is similar to PF with the exception that water is used and at pressures as
In Situ Remediation of MTBE-Contaminated Aquifers Using Propane Biosparging
2003-09-01
problem is decreasing the permeability by pneumatic or hydraulic fracturing . Pneumatic fracturing (PF) uses the injection of pressurized air 47 (up to...increase the biodegradation of the contaminants. Hydraulic fracturing is similar to PF with the exception that water is used and at pressures as high as
DOT National Transportation Integrated Search
1965-10-01
In the early of 1961 a research project was undertaken by the Louisiana Department of Highways in cooperation with the Bureau of Public Roads to study the effect of high intensity pneumatic rollers on the density of asphaltic concrete pavement using ...
21 CFR 890.3610 - Rigid pneumatic structure orthosis.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Rigid pneumatic structure orthosis. 890.3610 Section 890.3610 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES PHYSICAL MEDICINE DEVICES Physical Medicine Prosthetic Devices § 890.3610 Rigid...
21 CFR 890.3610 - Rigid pneumatic structure orthosis.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Rigid pneumatic structure orthosis. 890.3610 Section 890.3610 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES PHYSICAL MEDICINE DEVICES Physical Medicine Prosthetic Devices § 890.3610 Rigid...
21 CFR 890.3610 - Rigid pneumatic structure orthosis.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Rigid pneumatic structure orthosis. 890.3610 Section 890.3610 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES PHYSICAL MEDICINE DEVICES Physical Medicine Prosthetic Devices § 890.3610 Rigid...
21 CFR 890.3610 - Rigid pneumatic structure orthosis.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Rigid pneumatic structure orthosis. 890.3610 Section 890.3610 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES PHYSICAL MEDICINE DEVICES Physical Medicine Prosthetic Devices § 890.3610 Rigid...
21 CFR 890.3610 - Rigid pneumatic structure orthosis.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Rigid pneumatic structure orthosis. 890.3610 Section 890.3610 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES PHYSICAL MEDICINE DEVICES Physical Medicine Prosthetic Devices § 890.3610 Rigid...
New machining method of high precision infrared window part
NASA Astrophysics Data System (ADS)
Yang, Haicheng; Su, Ying; Xu, Zengqi; Guo, Rui; Li, Wenting; Zhang, Feng; Liu, Xuanmin
2016-10-01
Most of the spherical shell of the photoelectric multifunctional instrument was designed as multi optical channel mode to adapt to the different band of the sensor, there were mainly TV, laser and infrared channels. Without affecting the optical diameter, wind resistance and pneumatic performance of the optical system, the overall layout of the spherical shell was optimized to save space and reduce weight. Most of the shape of the optical windows were special-shaped, each optical window directly participated in the high resolution imaging of the corresponding sensor system, and the optical axis parallelism of each sensor needed to meet the accuracy requirement of 0.05mrad.Therefore precision machining of optical window parts quality will directly affect the photoelectric system's pointing accuracy and interchangeability. Processing and testing of the TV and laser window had been very mature, while because of the special nature of the material, transparent and high refractive rate, infrared window parts had the problems of imaging quality and the control of the minimum focal length and second level parallel in the processing. Based on years of practical experience, this paper was focused on how to control the shape and parallel difference precision of infrared window parts in the processing. Single pass rate was increased from 40% to more than 95%, the processing efficiency was significantly enhanced, an effective solution to the bottleneck problem in the actual processing, which effectively solve the bottlenecks in research and production.
Koch, Martin; Seidler, Hannes; Hellmuth, Alexander; Bornitz, Matthias; Lasurashvili, Nikoloz; Zahnert, Thomas
2013-07-01
There is a great demand for implantable microphones for future generations of implantable hearing aids, especially Cochlea Implants. An implantable middle ear microphone based on a piezoelectric membrane sensor for insertion into the incudostapedial gap is investigated. The sensor is designed to measure the sound-induced forces acting on the center of the membrane. The sensor mechanically couples to the adjacent ossicles via two contact areas, the sensor membrane and the sensor housing. The sensing element is a piezoelectric single crystal bonded on a titanium membrane. The sensor allows a minimally invasive and reversible implantation without removal of ossicles and without additional sensor fixation in the tympanic cavity. This study investigates the implantable microphone sensor and its implantation concept. It intends to quantify the influence of the sensor's insertion position on the achievable microphone sensitivity. The investigation considers anatomical and pathological variations of the middle ear geometry and its space limitations. Temporal bone experiments on a laboratory model show that anatomical and pathological variations of the middle ear geometry can prevent the sensor from being placed optimally within the incudostapedial joint. Beyond scattering of transfer functions due to anatomic variations of individual middle ears there is the impact of variations in the sensor position within the ossicular chain that has a considerable effect on the transfer characteristics of the middle ear microphone. The centering of the sensor between incus and stapes, the direction of insertion (membrane to stapes or to incus) and the effect of additional contact points with surrounding anatomic structures affect the signal yield of the implanted sensor. The presence of additional contact points has a considerably impact on the sensitivity, yet the microphone sensitivity is quite robust against small changes in the positioning of the incus on the sensor. Signal losses can be avoided by adjusting the position of the sensor within the joint. The findings allow the development of an improved surgical insertion technique to ensure maximally achievable signal yield of the membrane sensor in the ISJ and provides valuable knowledge for a future design considerations including sensor miniaturization and geometry. Measurements of the implanted sensor in temporal bone specimens showed a microphone sensitivity in the order of 1 mV/Pa. This article is part of a special issue entitled "MEMRO 2012". Copyright © 2012 Elsevier B.V. All rights reserved.
Toward a digital camera to rival the human eye
NASA Astrophysics Data System (ADS)
Skorka, Orit; Joseph, Dileepan
2011-07-01
All things considered, electronic imaging systems do not rival the human visual system despite notable progress over 40 years since the invention of the CCD. This work presents a method that allows design engineers to evaluate the performance gap between a digital camera and the human eye. The method identifies limiting factors of the electronic systems by benchmarking against the human system. It considers power consumption, visual field, spatial resolution, temporal resolution, and properties related to signal and noise power. A figure of merit is defined as the performance gap of the weakest parameter. Experimental work done with observers and cadavers is reviewed to assess the parameters of the human eye, and assessment techniques are also covered for digital cameras. The method is applied to 24 modern image sensors of various types, where an ideal lens is assumed to complete a digital camera. Results indicate that dynamic range and dark limit are the most limiting factors. The substantial functional gap, from 1.6 to 4.5 orders of magnitude, between the human eye and digital cameras may arise from architectural differences between the human retina, arranged in a multiple-layer structure, and image sensors, mostly fabricated in planar technologies. Functionality of image sensors may be significantly improved by exploiting technologies that allow vertical stacking of active tiers.
Study to Expand Simulation Cockpit Displays of Advanced Sensors
1981-03-01
common source is being used for multiple sensor types). If inde- pendent displays and controls are desired then two independent video sources or sensor...line is inserted in each gap, the result is the familiar 211 in- terlace. If two lines are inserted, the result is 31l interlace, and so on. The total...symbol generators. If these systems are oper- ating at various scan rates and if a common display device, such as a multifunction display (MFD) is to
High-Throughput and Label-Free Single Nanoparticle Sizing Based on Time-Resolved On-Chip Microscopy
2015-02-17
12,13 soot ,6,14 ice crystals in clouds,15 and engineered nano- materials,16 among others. While there exist various nanoparticle detection and sizing...the sample of interest is placed on an optoelectronic sensor -array with typically less than 0.5 mm gap (z2) between the sample and sensor planes such...that, under unit mag- nification, the entire sensor active area serves as the imaging FOV, easily reaching >2030 mm2 with state-of-the-art CMOS
Dielectric elastomer actuators used for pneumatic valve technology
NASA Astrophysics Data System (ADS)
Giousouf, Metin; Kovacs, Gabor
2013-10-01
Dielectric elastomer actuators have been investigated for applications in the field of pneumatic automation technology. We have developed different valve designs with stacked dielectric elastomer actuators and with integrated high voltage converters. The actuators were made using VHB-4910 material and a stacker machine for automated fabrication of the cylindrical actuators. Typical characteristics of pneumatic valves such as flow rate, power consumption and dynamic behaviour are presented. For valve construction the force and stroke parameters of the dielectric elastomer actuator have been measured. Further, benefits for valve applications using dielectric elastomers are shown as well as their potential operational area. Finally, challenges are discussed that are relevant for the use of elastomer actuators in valves for industrial applications.
Liu, Hongyun; Li, Kaiyuan; Zhang, Zhengbo; Guo, Junyan; Wang, Weidong
2012-11-01
The correlation coefficients between arterial occlusion pressure and systolic blood pressure, diastolic blood pressure, limb circumference, body mass etc were obtained through healthy volunteer experiments, in which tourniquet were applied on upper/lower extremities. The prediction equations were derived from the data of experiments by multiple regression analysis. Based on the microprocessor C8051F340, a new pneumatic tourniquet system that can determine tourniquet pressure in synchrony with systolic blood pressure was developed and verified the function and stability of designed system. Results showed that the pneumatic tourniquet which automatically adjusts occlusion pressure in accordance with systolic blood pressure could stop the flow of blood to get a bloodless field.
Microfluidic and Label-Free Multi-Immunosensors Based on Carbon Nanotube Microelectrodes
NASA Astrophysics Data System (ADS)
Tsujita, Yuichi; Maehashi, Kenzo; Matsumoto, Kazuhiko; Chikae, Miyuki; Takamura, Yuzuru; Tamiya, Eiichi
2009-06-01
We fabricated microfluidic and label-free multi-immunosensors by the integration of carbon nanotube (CNT)-arrayed electrodes and microchannels with pneumatic micropumps made of poly(dimethylsiloxane). In the microfluidic systems, four kinds of sample solutions were transported from each liquid inlet to microchannels using six pneumatic micropumps. As a result, two kinds of antibodies were immobilized onto different CNT electrodes using the microfluidic systems. Next, two kinds of cancer markers, prostate specific antigen and human chorionic gonadotropin in phosphate buffer solution, were simultaneously detected by differential pulse voltammetry. Therefore, microfludic multi-immunosensors based on CNT electrodes and pneumatic micropumps are useful for the development of multiplex hand-held biosensors.
Liquid-metal dip seal with pneumatic spring
Poindexter, Allan M.
1977-01-01
An improved liquid-metal dip seal for sealing the annulus between rotating plugs in the reactor vessel head of a liquid-metal fast-breeder nuclear reactor has two legs of differing widths communicating under a seal blade; the wide leg is also in communication with cover gas of the reactor and the narrow leg is also in communication with an isolated plug annulus above the seal. The annulus contains inert gas which acts as a pneumatic spring. Upon increasing cover gas pressure which depresses the level in the wide leg and greatly increases the level in the narrow leg, the pneumatic spring is compressed, and resists further level changes, thus preventing radioactive cover gas from bubbling through the seal.
46 CFR 108.409 - Location and spacing of tubing in pneumatic fire detection system.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 4 2013-10-01 2013-10-01 false Location and spacing of tubing in pneumatic fire detection system. 108.409 Section 108.409 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS DESIGN AND EQUIPMENT Fire Extinguishing Systems § 108.409 Location...
46 CFR 108.409 - Location and spacing of tubing in pneumatic fire detection system.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 4 2012-10-01 2012-10-01 false Location and spacing of tubing in pneumatic fire detection system. 108.409 Section 108.409 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS DESIGN AND EQUIPMENT Fire Extinguishing Systems § 108.409 Location...
46 CFR 108.409 - Location and spacing of tubing in pneumatic fire detection system.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 46 Shipping 4 2014-10-01 2014-10-01 false Location and spacing of tubing in pneumatic fire detection system. 108.409 Section 108.409 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS DESIGN AND EQUIPMENT Fire Extinguishing Systems § 108.409 Location...
46 CFR 108.409 - Location and spacing of tubing in pneumatic fire detection system.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 4 2011-10-01 2011-10-01 false Location and spacing of tubing in pneumatic fire detection system. 108.409 Section 108.409 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS DESIGN AND EQUIPMENT Fire Extinguishing Systems § 108.409 Location...
Assessment of Uinta Basin Oil and Natural Gas Well Pad Pneumatic Controller Emissions
In the fall of 2016, a field study was conducted in the Uinta Basin Utah to improve information on oil and natural gas well pad pneumatic controllers (PCs) and emission measurement methods. A total of 80 PC systems at five oil sites (supporting six wells) and three gas sites (sup...
Evaluation of elastomers as gasket materials in pneumatic and hydraulic systems
NASA Technical Reports Server (NTRS)
Bright, C. W.; Lockhart, B. J.
1972-01-01
In the search for superior materials from which to make gaskets for pneumatic and hydraulic systems, promising materials were selected and tested. The testing was conducted in two phases. Those materials that passed the tests of Phase 1 were tested in Phase 2, and categorized in the order of preference.
49 CFR 195.307 - Pressure testing aboveground breakout tanks.
Code of Federal Regulations, 2010 CFR
2010-10-01
... placed in service after October 2, 2000, pneumatic testing must be in accordance with section 5.3 of API Specification 12 F (incorporated by reference, see § 195.3). (b) For aboveground breakout tanks built to API Standard 620 and first placed in service after October 2, 2000, hydrostatic and pneumatic testing must be...
Code of Federal Regulations, 2014 CFR
2014-07-01
... Service Valve 1 6.42 Connector 5.71 Open-Ended Line 11.27 Pressure Relief Valve 2.01 Meter 2.93 Population... Pneumatic Device Vents 2 18.20 Intermittent Bleed Pneumatic Device Vents 2 2.35 1 Valves include control...
Code of Federal Regulations, 2013 CFR
2013-07-01
... Service Valve 1 6.42 Connector 5.71 Open-Ended Line 11.27 Pressure Relief Valve 2.01 Meter 2.93 Population... Pneumatic Device Vents 2 18.20 Intermittent Bleed Pneumatic Device Vents 2 2.35 1 Valves include control...
2003-12-01
by pneumatic or hydraulic fracturing . Pneumatic fracturing (PF) uses the injection of pressurized air 47 (up to 175 psi) in to the formation that...contaminants. Hydraulic fracturing is similar to PF with the exception that water is used and at pressures as high as 2000 psi. Technical questions
The Pneumatic Fracturing Extraction (PFE) process developed by Accutech Remedial Systems, Inc. makes it possible to use vapor extraction to remove volatile organics at increased rates from a broader range of vadose zones. The low permeability of silts, clays, shales, etc. would o...
Pneumatic shutoff and time-delay valve operates at controlled rate
NASA Technical Reports Server (NTRS)
Horning, J. L.; Tomlinson, L. E.
1966-01-01
Shutoff and time delay valve, which incorporates a metering spool that moves at constant velocity under pneumatic pressure and spring compression, increases fluid-flow area at a uniform rate. Diaphragm areas, control cavity volume, and bleed-orifice size may be varied to give any desired combination of time delay and spool travel time.
Inexpensive Dramatic Pneumatic Lift
ERIC Educational Resources Information Center
Morse, Robert A.
2017-01-01
Various experiments and demonstrations relate air pressure and air pressure difference to force and area. Carpenter and Minnix describe a large-scale pneumatic lift in which a person sitting on a board atop a plastic garbage bag is lifted when the bag is connected to the exhaustport of a vacuum cleaner, which easily lifts the person. This article…
NASA Astrophysics Data System (ADS)
Orekhova, T. N.; Nosov, O. A.; Prokopenko, V. S.; Kachaev, A. E.
2018-03-01
The improvement of the design of the pneumatic mixers aimed at the possibility of obtaining homogeneous disperse systems, while the resource and energy saving issues play an important role in the conditions of enterprises that use this type of equipment in their technological chain, is described in the article.
DOT National Transportation Integrated Search
1978-12-01
This study is the final phase of a muck pipeline program begun in 1973. The objective of the study was to evaluate a pneumatic pipeline system for muck haulage from a tunnel excavated by a tunnel boring machine. The system was comprised of a muck pre...
Design and Control of a Pneumatically Actuated Transtibial Prosthesis.
Zheng, Hao; Shen, Xiangrong
2015-04-01
This paper presents the design and control of a pneumatically actuated transtibial prosthesis, which utilizes a pneumatic cylinder-type actuator to power the prosthetic ankle joint to support the user's locomotion. The pneumatic actuator has multiple advantages over the traditional electric motor, such as light weight, low cost, and high power-to-weight ratio. The objective of this work is to develop a compact and lightweight transtibial prosthesis, leveraging the multiple advantages provided by this highly competitive actuator. In this paper, the design details of the prosthesis are described, including the determination of performance specifications, the layout of the actuation mechanism, and the calculation of the torque capacity. Through the authors' design calculation, the prosthesis is able to provide sufficient range of motion and torque capacity to support the locomotion of a 75 kg individual. The controller design is also described, including the underlying biomechanical analysis and the formulation of the finite-state impedance controller. Finally, the human subject testing results are presented, with the data indicating that the prosthesis is able to generate a natural walking gait and sufficient power output for its amputee user.
Yan, Peng; Minaker, Samuel; Mandelcorn, Efrem D
2016-06-01
Localization of retinal breaks in rhegmatogenous retinal detachment (RRD) after pneumatic retinopexy (PR) can be challenging once the retina is reattached. Laser can be applied to the pigmented and always-attached ora serrata in the meridian of the retinal breaks prior to pneumatic retinopexy, resulting in subsequent rapid localization of the breaks even in the presence of a gas bubble or media opacity. Ten cases of indirect laser photocoagulation marking at the ora prior to intraocular gas injection in PR for RRD. Subsequent laser retinopexy was completed 48 hours after utilizing the landmarks at the ora to localize the reattached retinal breaks. In all 10 cases, laser photocoagulation marking was easily applied to the ora in the meridian of the retinal breaks prior to gas injection with no complications. The retinal breaks were subsequently identified 48 hours after gas injection. Laser marking of the ora prior to pneumatic retinopexy is a rapid and effective way to localize the re-attached retina breaks. [Ophthalmic Surg Lasers Imaging Retina. 2016;47:570-572.]. Copyright 2016, SLACK Incorporated.
Development of a compact portable driver for a pneumatic ventricular assist device.
Nishinaka, Tomohiro; Taenaka, Yoshiyuki; Tatsumi, Eisuke; Ohnishi, Hiroyuki; Homma, Akihiko; Shioya, Kyoko; Mizuno, Toshihide; Tsukiya, Tomonori; Mushika, Sadahiko; Hashiguchi, Yasuhiro; Suzuki, Akira; Kitamura, Soichiro
2007-01-01
The Toyobo-National Cardiovascular Center pneumatic ventricular assist device (Toyobo-NCVC VAD) is widely used in Japan; however, the current pneumatic drivers have some drawbacks, including their large size, heavy weight, and high power consumption. These issues cause difficulty with mobility and contribute to an unsatisfactory quality of life for patients. Because it is urgently necessary to improve patients' safety and quality of life, we have developed a compact, low-noise, portable VAD driver by utilizing an electrohydraulic actuator consisting of a brushless DC motor and a regenerative pump. This unit can be actuated for as long as 2 h with two rechargeable lightweight batteries as well as with external AC power. It is compact in size (33 x 25 x 43 cm) and light in weight (13 kg), and the unit is carried on a mobile wheeled cart. In vitro testing with a Toyobo-NCVC VAD demonstrated a sufficient pumping capacity of up to 8 l/min. We conclude that this newly-developed compact portable driver can provide a better quality of life and improved safety for patients using protracted pneumatic VAD support.
NASA Astrophysics Data System (ADS)
Yang, Shaohua; Long, Wei; Chen, Yajun
2018-03-01
In this paper, the control mechanism and mathematical description of the microfluidic flow in the microfluidic process of the PDMS membrane type pneumatic micro-valve were studied. The velocity and pressure variation law of the velocity field inside micro valve was analyzed by numerical simulation method. The influence of the two kinds of inlet drive modes on the working effect and the pressure flow characteristics of the pneumatic micro-valve was studied. The structure of the elastic solid valve diaphragm under the dual action of the airway and the liquid channel was analyzed. Deformation and stress distribution. The results show that the gas flow in the gas flow channel under the diaphragm by the vacuum part of the role of the formation of a suction gas vortex, pressure-driven mode was easier under the diaphragm to produce a strong gas vortex, resulting in internal and external pressure to promote diaphragm cut-off liquid channel; In the pressure pneumatic mode, the stress at both ends of the diaphragm was smaller, the membrane was not easy to tear failure.
Isen, Kenan
2012-01-01
To assess the efficacy and safety of ureteroscopic pneumatic lithotripsy for multiple ureteric stones. 36 patients with multiple ureteric stones were treated with ureteroscopic lithotripsy (URSL). A 8/9.8-Fr Wolf semirigid ureteroscope and pneumatic lithotripter were used for stone fragmentation. 87 stones were treated with URSL. Successful fragmentation was achieved in 77 (88.5%) of the stones. The retreatment rate was 11.5%. The stone-free rate (SFR) of lower ureteric stones (93.3%) and middle ureteric stones (87.5%) was significantly higher compared with upper (73.3%) ureteric stones (p < 0.05). For patients with stones less than 1 cm and greater than 1 cm, the SFR was 91.5 and 75.0%, respectively (p < 0.05). Perforation occurred in 1 patient, mucosal injury occurred in 5 and stone migration in 5. No long-term complication was observed in any patient. Ureteroscopic pneumatic lithotripsy is still a reasonable treatment option for multiple ureteric stones. The procedure has high success rates with minimal morbidity. However, success rate can be affected by stone size and ureteric location. Copyright © 2012 S. Karger AG, Basel.
Series Pneumatic Artificial Muscles (sPAMs) and Application to a Soft Continuum Robot.
Greer, Joseph D; Morimoto, Tania K; Okamura, Allison M; Hawkes, Elliot W
2017-01-01
We describe a new series pneumatic artificial muscle (sPAM) and its application as an actuator for a soft continuum robot. The robot consists of three sPAMs arranged radially round a tubular pneumatic backbone. Analogous to tendons, the sPAMs exert a tension force on the robot's pneumatic backbone, causing bending that is approximately constant curvature. Unlike a traditional tendon driven continuum robot, the robot is entirely soft and contains no hard components, making it safer for human interaction. Models of both the sPAM and soft continuum robot kinematics are presented and experimentally verified. We found a mean position accuracy of 5.5 cm for predicting the end-effector position of a 42 cm long robot with the kinematic model. Finally, closed-loop control is demonstrated using an eye-in-hand visual servo control law which provides a simple interface for operation by a human. The soft continuum robot with closed-loop control was found to have a step-response rise time and settling time of less than two seconds.
Design and Control of a Pneumatically Actuated Transtibial Prosthesis
Zheng, Hao; Shen, Xiangrong
2015-01-01
This paper presents the design and control of a pneumatically actuated transtibial prosthesis, which utilizes a pneumatic cylinder-type actuator to power the prosthetic ankle joint to support the user's locomotion. The pneumatic actuator has multiple advantages over the traditional electric motor, such as light weight, low cost, and high power-to-weight ratio. The objective of this work is to develop a compact and lightweight transtibial prosthesis, leveraging the multiple advantages provided by this highly competitive actuator. In this paper, the design details of the prosthesis are described, including the determination of performance specifications, the layout of the actuation mechanism, and the calculation of the torque capacity. Through the authors’ design calculation, the prosthesis is able to provide sufficient range of motion and torque capacity to support the locomotion of a 75 kg individual. The controller design is also described, including the underlying biomechanical analysis and the formulation of the finite-state impedance controller. Finally, the human subject testing results are presented, with the data indicating that the prosthesis is able to generate a natural walking gait and sufficient power output for its amputee user. PMID:26146497
Series Pneumatic Artificial Muscles (sPAMs) and Application to a Soft Continuum Robot
Greer, Joseph D.; Morimoto, Tania K.; Okamura, Allison M.; Hawkes, Elliot W.
2017-01-01
We describe a new series pneumatic artificial muscle (sPAM) and its application as an actuator for a soft continuum robot. The robot consists of three sPAMs arranged radially round a tubular pneumatic backbone. Analogous to tendons, the sPAMs exert a tension force on the robot’s pneumatic backbone, causing bending that is approximately constant curvature. Unlike a traditional tendon driven continuum robot, the robot is entirely soft and contains no hard components, making it safer for human interaction. Models of both the sPAM and soft continuum robot kinematics are presented and experimentally verified. We found a mean position accuracy of 5.5 cm for predicting the end-effector position of a 42 cm long robot with the kinematic model. Finally, closed-loop control is demonstrated using an eye-in-hand visual servo control law which provides a simple interface for operation by a human. The soft continuum robot with closed-loop control was found to have a step-response rise time and settling time of less than two seconds. PMID:29379672
Sherwood, R J
1999-08-01
The ontogeny of human temporal bone pneumatization has been well studied from both comparative and clinical perspectives. While a difference in the extent of air cell distribution has been noted in our closest living relatives, chimpanzees and gorillas, the processes responsible have been relatively unexplored. To examine these processes, a large, age-graded series of hominoid skulls was radiographed and the progress of pneumatization recorded. Additionally, a subsample of 30 chimpanzees and 12 gorillas was subjected to high-resolution CT scanning. Neonatal specimens show a well-developed mastoid antrum, as well as a capacious hypotympanum extending into the petrous apex. In African apes, as in humans, the mastoid antrum serves as the focus for air cell expansion into the mastoid and immediately adjacent areas. In chimpanzees and gorillas, however, a pronounced lateral structure, described as the squamous antrum, serves as the focus of pneumatization for anterior structures such as the squamous and zygomatic. The diminution of this structure in Homo sapiens explains the difference in air cell distribution in these regions. Copyright 1999 Wiley-Liss, Inc.
Fatigue test of a fiberglass based composite panel. Increasing the lifetime of freight wagon
NASA Astrophysics Data System (ADS)
Sobek, M.; Baier, A.; Grabowski, Ł.; Majzner, M.
2016-08-01
In the XXI century transportation of goods plays a key role in the economy. Due to a good logistics the economy is able to grow fluently. Although land transportation is carried out mainly through trucks for the last several years there has been noted an increase in the percentage share of rail transport in the freight transport. The main goods transported by railways are mineral fuels, mining and quarrying products. They constitute the greater part of 70% of total transported goods. Transportation of material of such high weight, high hardness and with different shapes involves increased and accelerated wear and tear of the cargo space of the wagon. This process is also magnified by substances used to prevent overheating or goods theft. Usually they are in the form of chemical compounds powder, eg. Calcium. A very large impact on the wear of the freight wagons hull is made because of mechanical damage. Their source comes mostly from loading cargo with impetus and using heavy machines during unloading. A large number of cycles of loading and unloading during the working period causes abrasion of body and as a result after several years a wagon car qualifies for a major maintenance. Possibility of application composite panels in the process of renovating the wagons body could reduce the weight of whole train and prolong the service life between mandatory technical inspection. The Paper "Fatigue test of a fiberglass based composite panel. Increasing the lifetime of freight wagon" presents the research process and the results of the endurance test of the composite panel samples fixed to a metal plate. As a fixing method a stainless steel rivet nut and a stainless steel button head socket screws were chosen. Cyclic and multiple load were applied to test samples using a pneumatic cylinder. Such a methodology simulated the forces resulting from loading and unloading of the wagon and movement of the cargo during transport. In the study a dedicated stand equipped with a pneumatic cylinder and a strain gauge sensors was used. A logic controller to control pneumatic valves was used. Tests were carried out for different number of cycles. The paper contains the results and conclusions which will be useful for the actual application of composite panels on the hull of a freight wagon.
A Theoretical and Experimental Study for a Developing Flow in a Thin Fluid Gap
NASA Astrophysics Data System (ADS)
Wu, Qianhong; Lang, Ji; Jen, Kei-Peng; Nathan, Rungun; Vucbmss Team
2016-11-01
In this paper, we report a novel theoretical and experimental approach to examine a fast developing flow in a thin fluid gap. Although the phenomena are widely observed in industrial applications and biological systems, there is a lack of analytical approach that captures the instantaneous fluid response to a sudden impact. An experimental setup was developed that contains a piston instrumented with a laser displacement sensor and a pressure transducer. A sudden impact was imposed on the piston, creating a fast compaction on the thin fluid gap underneath. The motion of the piston was captured by the laser displacement sensor, and the fluid pressure build-up and relaxation was recorded by the pressure transducer. For this dynamic process, a novel analytical approach was developed. It starts with the inviscid limit when the viscous fluid effect has no time to appear. This short process is followed by a developing flow, in which the inviscid core flow region decreases and the viscous wall region increases until the entire fluid gap is filled with viscous fluid flow. A boundary layer integral method is used during the process. Lastly, the flow is completely viscous dominant featured by a typical squeeze flow in a thin gap. Excellent agreement between the theory and the experiment was achieved. The study presented herein, filling the gap in the literature, will have broad impact in industrial and biomedical applications. This research was supported by the National Science Foundation under Award #1511096.
A miniature extrinsic fiber Fabry-Perot pressure sensor based on fiber etching
NASA Astrophysics Data System (ADS)
Ge, Yixian; Wang, Ming; Yang, Chundi
2009-10-01
This paper presents a miniature fiber optic pressure sensor based on Fabry-Perot interference fabricated on the tip of a single mode (SM) fiber. The sensor measures only 125μm in diameter. A Fabry-Perot cavity and a thin silica diaphragm are fabricated by simple techniques involving only fusion splicing, cleaving, and wet chemical etching. Interference pattern of the sensor is analyzed and issues in sensor design are discussed. The overall chemical reaction of the fiber wet etching is specifically represented. Pressure testing system is carried out. By tracing a peak point in the interference spectrum, the gap length of the sensor can be demodulated. The sensor is made entirely of fused silica, whose structure has good stability, cabinet, simple for fabrication and low cost. It may also find uses in medical applications.
Inspection of cup-shaped steel parts from the I.D. side using eddy current
NASA Astrophysics Data System (ADS)
Griffiths, Erick W.; Pearson, Lee H.
2018-04-01
An eddy current method was developed to inspect cup-shaped steel parts from the I.D. side. During the manufacturing process of these parts, a thin Al tape foil is applied to the I.D. side of the part. One of the critical process parameters is that only one foil layer can be applied. An eddy current inspection system was developed to reject parts with more than one foil layer. The Al tape foil is cut to length to fit the inner diameter, however, after application of the foil there is a gap created between the beginning and end of the foil. It was found that this gap interfered with the eddy current inspection causing a false positive indication. To solve this problem a sensor design and data analysis process were developed to overcome the effects of these gaps. The developed system incorporates simultaneous measurements from multiple eddy current sensors and signal processing to achieve a reliable inspection.
Symmetric and Asymmetric Split Ring Resonators for Biosensing at Terahertz Frequencies
NASA Astrophysics Data System (ADS)
Naranjo, Guillermo; Peralta, Xomalin
2015-03-01
Food allergies have become a major health concern around the world. Peanut allergies are particularly important because they affect over 5 million people in the United States. We are proposing to develop a metamaterial-based sensor for peanut allergens. The detection mechanism we will tap into is the change in a metamaterial's resonant response due to the presence of a biomolecule in the gap region. Using a commercial-grade simulator based on the finite-difference time-domain method, we have simulated the terahertz transmission and reflection spectra of three different split-ring resonator designs with and without a biomolecule present. By modifying the overall symmetry of the resonator and the geometry of the gap region, we have modified the resonant response and increased its sensitivity. The increased sensitivity is demonstrated by repeating the simulations with a layer of peroxidase conjugated immunoglobulin G (PX-IgG) in the gap region and quantifying the resulting resonant shift. These results are the basis for the proposed allergen sensors. UTSA MBRS-RISE Research Training Program.
Sinus septi nasi: Anatomical study.
Mladina, Ranko; Antunović, Romano; Cingi, Cemal; Bayar Muluk, Nuray; Skitarelić, Neven
2017-04-01
The aim of this study was to perform a pioneering investigation into the incidence of pneumatization in human skulls. A total of 93 human skulls (≥20 years of age, 69 males, 24 females) were included in the study. The skulls were scanned in a fixed position using cone beam computed tomography (CBCT). The pneumatized space parameters within the nasal septum-width, length, and height-were measured. Two types of finding were identified: (a) Pneumatization, named "sinus septi nasi" (SSN), and (b) "spongy bone" (SB). The results showed SSN in 32 of the 93 skulls (34.4%). The SSN formations were from 0.5 to 4.2 mm wide, 3.5 to 18.8 mm long, and 3.8 to 17.7 mm high. Tumefactions filled with SB were found in 61 of the 93 skulls (65.59%). These were not suitable for precise measurements since the outer borders were not strictly and well defined on CT scans (perhaps because of the preparation process). In conclusion, the perpendicular plate of the ethmoidal bone is not always compact bone; in 34.4% of cases, it shows a degree of pneumatization. In contrast, an enlarged formation filled with SB is present in 65.59% of cases. The possible sources of pneumatization of this little-investigated region are discussed: sphenoid sinus, frontal sinus, and vomeronasal organ. Clin. Anat. 30:312-317, 2017. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.
DOE Office of Scientific and Technical Information (OSTI.GOV)
O’Reilly, Michael K., E-mail: moreilly1@mater.ie; Ryan, David; Sugrue, Gavin
PurposeTransradial pneumatic compression devices can be used to achieve haemostasis following radial artery puncture. This article describes a novel technique for acquiring haemostasis of arterio-venous haemodialysis fistula access sites without the need for suture placement using one such compression device.Materials and MethodsA retrospective review of fistulograms with or without angioplasty/thrombectomy in a single institution was performed. 20 procedures performed on 12 patients who underwent percutaneous intervention of failing or thrombosed arterio-venous fistulas (AVF) had 27 puncture sites. Haemostasis was achieved using a pneumatic compression device at all access sites. Procedure details including size of access sheath, heparin administration and complicationsmore » were recorded.ResultsTwo diagnostic fistulograms, 14 fistulograms and angioplasties and four thrombectomies were performed via access sheaths with an average size (±SD) of 6 Fr (±1.12). IV unfractionated heparin was administered in 11 of 20 procedures. Haemostasis was achieved in 26 of 27 access sites following 15–20 min of compression using the pneumatic compression device. One case experienced limited bleeding from an inflow access site that was successfully treated with reinflation of the device for a further 5 min. No other complication was recorded.ConclusionsHaemostasis of arterio-venous haemodialysis fistula access sites can be safely and effectively achieved using a pneumatic compression device. This is a technically simple, safe and sutureless technique for acquiring haemostasis after AVF intervention.« less
Asymmetric Fuzzy Control of a Positive and Negative Pneumatic Pressure Servo System
NASA Astrophysics Data System (ADS)
Yang, Gang; Du, Jing-Min; Fu, Xiao-Yun; Li, Bao-Ren
2017-11-01
The pneumatic pressure control systems have been used in some fields. However, the researches on pneumatic pressure control mainly focus on constant pressure regulation. Poor dynamic characteristics and strong nonlinearity of such systems limit its application in the field of pressure tracking control. In order to meet the demand of generating dynamic pressure signal in the application of the hardware-in-the-loop simulation of aerospace engineering, a positive and negative pneumatic pressure servo system is provided to implement dynamic adjustment of sealed chamber pressure. A mathematical model is established with simulation and experiment being implemented afterwards to discuss the characteristics of the system, which shows serious asymmetry in the process of charging and discharging. Based on the analysis of the system dynamics, a fuzzy proportional integral derivative (PID) controller with asymmetric fuzzy compensator is proposed. Different from conventional adjusting mechanisms employing the error and change in error of the controlled variable as input parameters, the current chamber pressure and charging or discharging state are chosen as inputs of the compensator, which improves adaptability. To verify the effectiveness and performance of the proposed controller, the comparison experiments tracking sinusoidal and square wave commands are conducted. Experimental results show that the proposed controller can obtain better dynamic performance and relatively consistent control performance across the scope of work (2-140 kPa). The research proposes a fuzzy control method to overcome asymmetry and enhance adaptability for the positive and negative pneumatic pressure servo system.
Does Pneumatic Tube System Transport Contribute to Hemolysis in ED Blood Samples?
Phelan, Michael P.; Reineks, Edmunds Z.; Hustey, Fredric M.; Berriochoa, Jacob P.; Podolsky, Seth R.; Meldon, Stephen; Schold, Jesse D.; Chamberlin, Janelle; Procop, Gary W.
2016-01-01
Introduction Our goal was to determine if the hemolysis among blood samples obtained in an emergency department and then sent to the laboratory in a pneumatic tube system was different from those in samples that were hand-carried. Methods The hemolysis index is measured on all samples submitted for potassium analysis. We queried our hospital laboratory database system (SunQuest®) for potassium results for specimens obtained between January 2014 and July 2014. From facility maintenance records, we identified periods of system downtime, during which specimens were hand-carried to the laboratory. Results During the study period, 15,851 blood specimens were transported via our pneumatic tube system and 92 samples were hand delivered. The proportions of hemolyzed specimens in the two groups were not significantly different (13.6% vs. 13.1% [p=0.90]). Results were consistent when the criterion was limited to gross (3.3% vs 3.3% [p=0.99]) or mild (10.3% vs 9.8% [p=0.88]) hemolysis. The hemolysis rate showed minimal variation during the study period (12.6%–14.6%). Conclusion We found no statistical difference in the percentages of hemolyzed specimens transported by a pneumatic tube system or hand delivered to the laboratory. Certain features of pneumatic tube systems might contribute to hemolysis (e.g., speed, distance, packing material). Since each system is unique in design, we encourage medical facilities to consider whether their method of transport might contribute to hemolysis in samples obtained in the emergency department. PMID:27625719
Does Pneumatic Tube System Transport Contribute to Hemolysis in ED Blood Samples?
Phelan, Michael P; Reineks, Edmunds Z; Hustey, Fredric M; Berriochoa, Jacob P; Podolsky, Seth R; Meldon, Stephen; Schold, Jesse D; Chamberlin, Janelle; Procop, Gary W
2016-09-01
Our goal was to determine if the hemolysis among blood samples obtained in an emergency department and then sent to the laboratory in a pneumatic tube system was different from those in samples that were hand-carried. The hemolysis index is measured on all samples submitted for potassium analysis. We queried our hospital laboratory database system (SunQuest(®)) for potassium results for specimens obtained between January 2014 and July 2014. From facility maintenance records, we identified periods of system downtime, during which specimens were hand-carried to the laboratory. During the study period, 15,851 blood specimens were transported via our pneumatic tube system and 92 samples were hand delivered. The proportions of hemolyzed specimens in the two groups were not significantly different (13.6% vs. 13.1% [p=0.90]). Results were consistent when the criterion was limited to gross (3.3% vs 3.3% [p=0.99]) or mild (10.3% vs 9.8% [p=0.88]) hemolysis. The hemolysis rate showed minimal variation during the study period (12.6%-14.6%). We found no statistical difference in the percentages of hemolyzed specimens transported by a pneumatic tube system or hand delivered to the laboratory. Certain features of pneumatic tube systems might contribute to hemolysis (e.g., speed, distance, packing material). Since each system is unique in design, we encourage medical facilities to consider whether their method of transport might contribute to hemolysis in samples obtained in the emergency department.
Pérez de San Román-Mena, Laila; Simal-Julián, Juan Antonio; Miranda-Lloret, Pablo; Sanromán-Álvarez, Pablo; Botella-Asunción, Carlos
2017-08-01
The surgical approach to the petrous apex (PA) and petroclival junction (PCJ) remains a challenge. The carotid-clival window (CCW) represents the widest window available to approach the PCJ from a mediolateral endoscopic route. Here we define the CCW radiologically in nonpathological conditions, to establish the anatomic variability of the PCJ, relate this variability to pneumatization patterns, and evaluate some technical concerns conditioned by the CCW. This was an analytical study of 10 multislice computed tomography scans from patients without SB pathology. Bilateral measures were taken at the roof and floor levels of the lacerum canal (LC) and its posterior projection over the PCJ (segments DE and QR). All measures were compared across different pneumatization patterns. The DE and QR lengths were found to be the most important measures affecting the width of the CCW. Wide variability was observed, with a mean DE length of 8.52 mm (range, 2.4-12.8 mm) at the LC floor level and a mean QR length of 9.11 mm (range, 4.3-13.1 mm) at the LC roof level. The presence of retrocarotid pneumatization was statistically significantly associated with longer DE and QR segments. No differences were found among other pneumatization patterns. The CCW varies widely among individuals. The presence of pneumatization behind the paraclival carotid represents an advantageous characteristic when planning an endoscopic approach to the PCJ. Copyright © 2017 Elsevier Inc. All rights reserved.
Eye-in-Hand Manipulation for Remote Handling: Experimental Setup
NASA Astrophysics Data System (ADS)
Niu, Longchuan; Suominen, Olli; Aref, Mohammad M.; Mattila, Jouni; Ruiz, Emilio; Esque, Salvador
2018-03-01
A prototype for eye-in-hand manipulation in the context of remote handling in the International Thermonuclear Experimental Reactor (ITER)1 is presented in this paper. The setup consists of an industrial robot manipulator with a modified open control architecture and equipped with a pair of stereoscopic cameras, a force/torque sensor, and pneumatic tools. It is controlled through a haptic device in a mock-up environment. The industrial robot controller has been replaced by a single industrial PC running Xenomai that has a real-time connection to both the robot controller and another Linux PC running as the controller for the haptic device. The new remote handling control environment enables further development of advanced control schemes for autonomous and semi-autonomous manipulation tasks. This setup benefits from a stereovision system for accurate tracking of the target objects with irregular shapes. The overall environmental setup successfully demonstrates the required robustness and precision that remote handling tasks need.
Methods for Evaluating the Performance and Human Stress-Factors of Percussive Riveting
NASA Astrophysics Data System (ADS)
Ahn, Jonathan Y.
The aerospace industry automates portions of their manufacturing and assembly processes. However, mechanics still remain vital to production, especially in areas where automated machines cannot fit, or have yet to match the quality of human craftsmanship. One such task is percussive riveting. Because percussive riveting is associated with a high risk of injury, these tool must be certified prior to release. The major contribution of this thesis is to develop a test bench capable of percussive riveting for ergonomic evaluation purposes. The major issues investigated are: (i) automate the tool evaluation method to be repeatable; (ii) demonstrate use of displacement and force sensors; and (iii) correlate performance and risk exposure of percussive tools. A test bench equipped with servomotors and pneumatic cylinders to control xyz-position of a rivet gun and bucking bar simultaneously, is used to explore this evaluation approach.
Fiber optic sensor design for chemical process and environmental monitoring
NASA Astrophysics Data System (ADS)
Mahendran, R. S.; Harris, D.; Wang, L.; Machavaram, V. R.; Chen, R.; Kukureka, St. N.; Fernando, G. F.
2007-07-01
Cure monitoring is a term that is used to describe the cross-linking reactions in a thermosetting resin system. Advanced fiber reinforced composites are being used increasingly in a number of industrial sectors including aerospace, marine, sport, automotive and civil engineering. There is a general realization that the processing conditions that are used to manufacture the composites can have a major influence on its hot-wet mechanical properties. This paper is concerned with the design and demonstration of a number of sensor designs for in-situ cure monitoring of a model thermosetting resin system. Simple fixtures were constructed to enable a pair of cleaved optical fibers with a defined gap between the end-faces to be held in position. The resin system was introduced into this gap and the cure kinetics were followed by transmission infrared spectroscopy. A semi-empirical model was used to describe the cure process using the data obtained at different cure temperatures. The same sensor system was used to detect the ingress of moisture in the cured resin system.
Ding, Guoping; Zhang, Songchao; Cao, Hao; Gao, Bin; Zhang, Biyun
2017-06-10
The rotational magnetic field of radial magnetic bearings characterizes remarkable time and spatial nonlinearity due to the eddy current and induced electromagnetic field. It is significant to experimentally obtain the features of the rotational magnetic field of the radial magnetic bearings to validate the theoretical analysis and reveal the discipline of a rotational magnetic field. This paper developed thin-slice fiber Bragg grating-giant magnetostrictive material (FBG-GMM) magnetic sensors to measure air-gap flux density of a radial magnetic bearing with a rotating rotor; a radial magnetic bearing test rig was constructed and the rotational magnetic field with different rotation speed was measured. Moreover, the finite element method (FEM) was used to simulate the rotational magnetic field; the measurement results and FEM results were investigated, and it was concluded that the FBG-GMM sensors were capable of measuring the radial magnetic bearing's air gap flux density with a rotating rotor, and the measurement results showed a certain degree of accuracy.
Sensing and Virtual Worlds - A Survey of Research Opportunities
NASA Technical Reports Server (NTRS)
Moore, Dana
2012-01-01
Virtual Worlds (VWs) have been used effectively in live and constructive military training. An area that remains fertile ground for exploration and a new vision involves integrating various traditional and now non-traditional sensors into virtual worlds. In this paper, we will assert that the benefits of this integration are several. First, we maintain that virtual worlds offer improved sensor deployment planning through improved visualization and stimulation of the model, using geo-specific terrain and structure. Secondly, we assert that VWs enhance the mission rehearsal process, and that using a mix of live avatars, non-player characters, and live sensor feeds (e.g. real time meteorology) can help visualization of the area of operations. Finally, tactical operations are improved via better collaboration and integration of real world sensing capabilities, and in most situations, 30 VWs improve the state of the art over current "dots on a map" 20 geospatial visualization. However, several capability gaps preclude a fuller realization of this vision. In this paper, we identify many of these gaps and suggest research directions
An ultra-sensitive wearable accelerometer for continuous heart and lung sound monitoring.
Hu, Yating; Xu, Yong
2012-01-01
This paper presents a chest-worn accelerometer with high sensitivity for continuous cardio-respiratory sound monitoring. The accelerometer is based on an asymmetrical gapped cantilever which is composed of a bottom mechanical layer and a top piezoelectric layer separated by a gap. This novel structure helps to increase the sensitivity by orders of magnitude compared with conventional cantilever based accelerometers. The prototype with a resonant frequency of 1100Hz and a total weight of 5 gram is designed, constructed and characterized. The size of the prototype sensor is 35mm×18mm×7.8mm (l×w×t). A built-in charge amplifier is used to amplify the output voltage of the sensor. A sensitivity of 86V/g and a noise floor of 40ng/√Hz are obtained. Preliminary tests for recording both cardiac and respiratory signals are carried out on human body and the new sensor exhibits better performance compared with a high-end electronic stethoscope.
Gas detection with microelectromechanical Fabry-Perot interferometer technology in cell phone
NASA Astrophysics Data System (ADS)
Mannila, Rami; Hyypiö, Risto; Korkalainen, Marko; Blomberg, Martti; Kattelus, Hannu; Rissanen, Anna
2015-06-01
VTT Technical Research Centre of Finland has developed a miniaturized optical sensor for gas detection in a cell phone. The sensor is based on a microelectromechanical (MEMS) Fabry-Perot interferometer, which is a structure with two highly reflective surfaces separated by a tunable air gap. The MEMS FPI is a monolithic device, i.e. it is made entirely on one substrate in a batch process, without assembling separate pieces together. The gap is adjusted by moving the upper mirror with electrostatic force, so there are no actual moving parts. VTT has designed and manufactured a MEMS FPI based carbon dioxide sensor demonstrator which is integrated to a cell phone shield cover. The demonstrator contains light source, gas cell, MEMS FPI, detector, control electronics and two coin cell batteries as a power source. It is connected to the cell phone by Bluetooth. By adjusting the wavelength range and customizing the MEMS FPI structure, it is possible to selectively sense multiple gases.
Pneumatic versus laser ureteroscopic lithotripsy: a comparison of initial outcomes and cost.
Demir, Aslan; Karadağ, Mert Ali; Ceçen, Kurşat; Uslu, Mehmet; Arslan, Omer Erkam
2014-11-01
To audit the cost of laser versus pneumatic semirigid ureteroscopic lithotripsy and to analyze their relative initial outcomes and cost. Hundred and eighty-seven patients who underwent semirigid ureteroscopic lithotripsy were analyzed retrospectively in terms of age and sex of the patients; location and size of the stones; the type of probe and ancillary equipment such as guide wire, basket catheter, JJ stent requirements; irrigation amount; operation time; the cost of the anesthesia and further treatments such as a JJ stent removal operation and shock wave lithotripsy requirements and their costs. Two groups were formed based on this type of lithotripters, pneumatic and laser lithotripsy. Operation times (min.) in terms of the stone size, for stones <100 and >100 mm(2) were 20.75 ± 10.78 and 25.82 ± 14.23, respectively (p = 0.007). Operation times for the pneumatic and laser groups were 33.05 ± 11.36 and 15.25 ± 6.14, respectively (p < 0.05).The stone-free rates for pneumatic and laser groups were 89.6 % (n = 69) and 98.2 % (n = 108), respectively (p = 0.01). The mean cost of the operations for each of the study groups was 261.5 ± 66.13 and 311.7 ± 51.97 US$, respectively (p = 0.001). The mean cost in terms of the stone size, for stones <100 and >100 mm(2), was 272.86 ± 53.05 and 323.71 ± 66.88 US$, respectively (p = 0.01). It seems that usage of laser lithotripsy (LL) in patients with ureteral stones is more effective than pneumatic lithotripsy (PL) in terms of operation time and SF rate. On the other hand, the mean cost of LL seems to be more expensive than PL. Urologists should think these parameters before the choice of these two treatment modalities. The higher the effectiveness, the greater the cost.
Lovelock, D Michael; Zatcky, Joan; Goodman, Karyn; Yamada, Yoshiya
2014-06-01
Abdominal compression using a pneumatic abdominal compression belt developed in-house has been used to reduce respiratory motion of patients undergoing hypo-fractionated or single fraction stereotactic radio-ablative therapy for abdominal cancers. The clinical objective of belt usage was to reduce the cranial-caudal (CC) respiratory motion of the tumor to 5 mm or less during both CT simulation and treatment. A retrospective analysis was done to determine the effectiveness of the device and associated clinical procedures to reduce the CC respiratory motion of the tumor. 42 patients treated for tumors in the liver (30), adrenal glands (6), pancreas (3) and lymph nodes (3) using high dose hypofractionated radiotherapy between 2004 and the present were eligible for analysis. All patients had 2-3 radiopaque fiducial markers implanted near the tumor prior to simulation, or had clips from prior surgery. Integral to the belt is an inflatable air bladder that is positioned over the abdomen. The pneumatic pressure was set to a level in consultation with the patient. The CC motion was measured fluoroscopically with and without pneumatic pressure. Pneumatic pressure was used at all treatments to reduce to CC motion to that achieved at simulation. The mean CC motion with the belt in place, but no additional air pressure was 11.4 mm with a range of 5-20 mm. With the pressure applied, the mean CC motion was reduced to 4.4 mm with a range of 1-8 mm (P-value < 0.001). The clinical objective of reducing the CC motion of the tumor to a maximum excursion of 5 mm or less was achieved in 93% of cases. The use of a pneumatic compression belt and associated clinical procedures was found to result in a significant and frequently substantial reduction in the CC motion of the tumor.
NASA Technical Reports Server (NTRS)
Englar, Robert J.; Willie, F. Scott; Lee, Warren J.
1999-01-01
In the Task I portion of this NASA research grant, configuration development and experimental investigations have been conducted on a series of pneumatic high-lift and control surface devices applied to a generic High Speed Civil Transport (HSCT) model configuration to determine their potential for improved aerodynamic performance, plus stability and control of higher performance aircraft. These investigations were intended to optimize pneumatic lift and drag performance; provide adequate control and longitudinal stability; reduce separation flowfields at high angle of attack; increase takeoff/climbout lift-to-drag ratios; and reduce system complexity and weight. Experimental aerodynamic evaluations were performed on a semi-span HSCT generic model with improved fuselage fineness ratio and with interchangeable plain flaps, blown flaps, pneumatic Circulation Control Wing (CCW) high-lift configurations, plain and blown canards, a novel Circulation Control (CC) cylinder blown canard, and a clean cruise wing for reference. Conventional tail power was also investigated for longitudinal trim capability. Also evaluated was unsteady pulsed blowing of the wing high-lift system to determine if reduced pulsed mass flow rates and blowing requirements could be made to yield the same lift as that resulting from steady-state blowing. Depending on the pulsing frequency applied, reduced mass flow rates were indeed found able to provide lift augmentation at lesser blowing values than for the steady conditions. Significant improvements in the aerodynamic characteristics leading to improved performance and stability/control were identified, and the various components were compared to evaluate the pneumatic potential of each. Aerodynamic results were provided to the Georgia Tech Aerospace System Design Lab. to conduct the companion system analyses and feasibility study (Task 2) of theses concepts applied to an operational advanced HSCT aircraft. Results and conclusions from these experimental evaluations are presented herein, as are recommendations for further development and follow-on investigations. Also provided as an Appendix for reference are the basic results from the previous pneumatic HSCT investigations.
Light-Immune pH Sensor with SiC-Based Electrolyte-Insulator-Semiconductor Structure
NASA Astrophysics Data System (ADS)
Lin, Yi-Ting; Huang, Chien-Shiang; Chow, Lee; Lan, Jyun-Ming; Yang, Chia-Ming; Chang, Liann-Be; Lai, Chao-Sung
2013-12-01
An electrolyte-insulator-semiconductor (EIS) structure with high-band-gap semiconductor of silicon carbide is demonstrated as a pH sensor in this report. Two different sensing membranes, i.e., gadolinium oxide (Gd2O3) and hafnium oxide (HfO2), were investigated. The HfO2 film deposited by atomic layer deposition (ALD) at low temperature shows high pH sensing properties with a sensitivity of 52.35 mV/pH and a low signal of 4.95 mV due to light interference. The EIS structures with silicon carbide can provide better visible light immunity due to its high band gap that allows pH detection in an outdoor environment without degradation of pH sensitivity.
Recent Developments of Magnetoresistive Sensors for Industrial Applications
Jogschies, Lisa; Klaas, Daniel; Kruppe, Rahel; Rittinger, Johannes; Taptimthong, Piriya; Wienecke, Anja; Rissing, Lutz; Wurz, Marc Christopher
2015-01-01
The research and development in the field of magnetoresistive sensors has played an important role in the last few decades. Here, the authors give an introduction to the fundamentals of the anisotropic magnetoresistive (AMR) and the giant magnetoresistive (GMR) effect as well as an overview of various types of sensors in industrial applications. In addition, the authors present their recent work in this field, ranging from sensor systems fabricated on traditional substrate materials like silicon (Si), over new fabrication techniques for magnetoresistive sensors on flexible substrates for special applications, e.g., a flexible write head for component integrated data storage, micro-stamping of sensors on arbitrary surfaces or three dimensional sensing under extreme conditions (restricted mounting space in motor air gap, high temperatures during geothermal drilling). PMID:26569263
Onder, Ursula; Blauth, Michael; Kralinger, Franz; Schmoelz, Werner
2012-05-30
In our society the average age is increasing, as are the number of proximal humeral head fractures. For fixation of these fractures, an increasing number of implants are available. New fixation devices should be compared biomechanically with established methods in a standardized fashion. The test bench that was designed was intended to simulate abduction motion of the humerus actively induced by muscle forces. We used three pneumatic muscles to apply forces to the tendons of the musculus supraspinatus and the bifid musculus deltoideus. Thus, it was possible to create an active abduction in the scapular plane. Two different fracture models (with and without medial support) were stabilised with an angular stable plate in sawbone models to reproduce a known clinical outcome with the newly designed test setup. The resultant force acting on the proximal humerus reached approximately 47% BW (per cent body weight), which amounted to 329.0 N (SD: 21.76). The supraspinatus reached maximum forces of 254.7 N (SD: 20.1) and the deltoid muscle 258.9 N (SD: 16.5). Fracture gap instrumentation with medial support resulted in a significantly reduced per-cycle fracture gap motion. The performance evaluation showed that the simulator produced predicable, reproducible movements with physiological muscle force magnitudes.
A Self-Referenced Optical Intensity Sensor Network Using POFBGs for Biomedical Applications
Moraleda, Alberto Tapetado; Montero, David Sánchez; Webb, David J.; García, Carmen Vázquez
2014-01-01
This work bridges the gap between the remote interrogation of multiple optical sensors and the advantages of using inherently biocompatible low-cost polymer optical fiber (POF)-based photonic sensing. A novel hybrid sensor network combining both silica fiber Bragg gratings (FBG) and polymer FBGs (POFBG) is analyzed. The topology is compatible with WDM networks so multiple remote sensors can be addressed providing high scalability. A central monitoring unit with virtual data processing is implemented, which could be remotely located up to units of km away. The feasibility of the proposed solution for potential medical environments and biomedical applications is shown. PMID:25615736
Polyaniline nanowires-gold nanoparticles hybrid network based chemiresistive hydrogen sulfide sensor
NASA Astrophysics Data System (ADS)
Shirsat, Mahendra D.; Bangar, Mangesh A.; Deshusses, Marc A.; Myung, Nosang V.; Mulchandani, Ashok
2009-02-01
We report a sensitive, selective, and fast responding room temperature chemiresistive sensor for hydrogen sulfide detection and quantification using polyaniline nanowires-gold nanoparticles hybrid network. The sensor was fabricated by facile electrochemical technique. Initially, polyaniline nanowires with a diameter of 250-320 nm bridging the gap between a pair of microfabricated gold electrodes were synthesized using templateless electrochemical polymerization using a two step galvanostatic technique. Polyaniline nanowires were then electrochemically functionalized with gold nanoparticles using cyclic voltammetry technique. These chemiresistive sensors show an excellent limit of detection (0.1 ppb), wide dynamic range (0.1-100 ppb), and very good selectivity and reproducibility.
A self-referenced optical intensity sensor network using POFBGs for biomedical applications.
Tapetado Moraleda, Alberto; Sánchez Montero, David; Webb, David J; Vázquez García, Carmen
2014-12-12
This work bridges the gap between the remote interrogation of multiple optical sensors and the advantages of using inherently biocompatible low-cost polymer optical fiber (POF)-based photonic sensing. A novel hybrid sensor network combining both silica fiber Bragg gratings (FBG) and polymer FBGs (POFBG) is analyzed. The topology is compatible with WDM networks so multiple remote sensors can be addressed providing high scalability. A central monitoring unit with virtual data processing is implemented, which could be remotely located up to units of km away. The feasibility of the proposed solution for potential medical environments and biomedical applications is shown.
ERIC Educational Resources Information Center
Dade County Public Schools, Miami, FL.
This document presents an outline for a 135-hour course designed to familiarize the student with the operation, inspection, and repair of aircraft fuel, hydraulic, and pneumatic systems. It is designed to help the trainee master the knowledge and skills necessary to become an aviation airframe mechanic. The aviation airframe maintenance technician…
Federal Register 2010, 2011, 2012, 2013, 2014
2013-12-27
... (``Zhongce'') requested a changed circumstances review of the antidumping duty order on certain new pneumatic...; telephone: 202-482-4987 or 202-482-5848, respectively. SUPPLEMENTARY INFORMATION: Background On September 4, 2008, the Department published in the Federal Register an antidumping duty order on OTR tires from the...
Endoscopic Pneumatic Dilation for Esophageal Achalasia.
Markar, Sheraz; Zaninotto, Giovanni
2018-04-01
Pneumatic dilation is a well-established treatment modality that has withstood the test of time. Prospective and randomized trials have shown that in expert hands, it provides results similar to a laparoscopic Heller myotomy with fundoplication. In addition, it should be considered the primary form of treatment in patients who experience recurrence of symptoms after a surgical myotomy.
49 CFR 571.109 - Standard No. 109; New pneumatic and certain specialty tires.
Code of Federal Regulations, 2013 CFR
2013-10-01
... deformation and allows no loss of air through the portion that it comprises of the tire-rim pressure chamber... rim that undergoes no permanent deformation and allows no loss of air through the portion that it... 49 Transportation 6 2013-10-01 2013-10-01 false Standard No. 109; New pneumatic and certain...
ERIC Educational Resources Information Center
Tucker, James D.
This training module on the troubleshooting of an electromechanical system, The Westinghouse Programmable Logic Controller (PLC) controlling a pneumatic robot, is used for a troubleshooting unit in an electromechanical systems/robotics and automation systems course. In this unit, students locate and repair a defect in a PLC-operated machine. The…
130. Photographic copy of drawing (undated, original drawing in Archives, ...
130. Photographic copy of drawing (undated, original drawing in Archives, Public Affairs Department, Sears Merchandise Group, Hoffman Estates, Illinois). Engineer unknown. Full size. Pneumatic tube cartridges used at the time of the Plant closing. 4' PNEUMATIC TUBE SYSTEM - 11' LEATHER CARRIER - Sears Roebuck & Company Mail Order Plant, Merchandise Building, 924 South Homan Avenue, Chicago, Cook County, IL
131. Photographic copy of drawing (undated, original drawing in Archives, ...
131. Photographic copy of drawing (undated, original drawing in Archives, Public Affairs Department, Sears Merchandise Group, Hoffman Estates, Illinois). Engineer unknown. Full size. Pneumatic tube cartridges used at the time of the Plant closing. 4' PNEUMATIC TUBE SYSTEM - 11' LEATHER CARRIER - Sears Roebuck & Company Mail Order Plant, Merchandise Building, 924 South Homan Avenue, Chicago, Cook County, IL
Federal Register 2010, 2011, 2012, 2013, 2014
2011-04-26
... sites. They can also be used to perform ``rough grading'' in road construction. \\10\\ A straddle carrier... commonly used in maintenance of unpaved roads and road construction to prepare the base course onto which... DEPARTMENT OF COMMERCE International Trade Administration [C-570-913] New Pneumatic Off-the-Road...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-01-06
...-the-Road Tires From the People's Republic of China: Partial Rescission of Countervailing Duty... the countervailing duty order on Certain New Pneumatic Off-the-Road Tires (OTR Tires) from the People... to the following six companies: 1. Aeolus Tyre Co. Ltd. (Aeolus) 2. Guizhou Tire Co. Ltd. (GTC) 3...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-11-30
...-the-Road Tires From the People's Republic of China: Partial Rescission of Countervailing Duty... the countervailing duty order on certain new pneumatic off-the-road tires (OTR Tires) from the People... Guizhou Tyre Co., Ltd., Guizhou Advanced Rubber Co., Ltd., and Guizhou Tyre Import and Export Corporation...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-03-18
...-the-Road Tires From the People's Republic of China: Notice of Partial Rescission of Antidumping Duty.... DATES: Effective Date: March 18, 2011. FOR FURTHER INFORMATION CONTACT: Raquel Silva or Frances Veith... antidumping duty order on certain new pneumatic off-the-road tires (``OTR tires'') from the People's Republic...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-12-10
...-the-Road Tires From the People's Republic of China: Rescission, in Part, of Countervailing Duty... the countervailing duty order on certain new pneumatic off-the-road tires (OTR Tires) from the People... the following seven companies: Shandong Huitong Tyre Co., Ltd.; Qingdao Hengda Tyres Co., Ltd...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-05-06
...-the-Road Tires from the People's Republic of China: Partial Rescission of Countervailing Duty... the countervailing duty order on Certain New Pneumatic Off-the-Road Tires (OTR Tires) from the People...: May 6, 2010. FOR FURTHER INFORMATION CONTACT: Andrew Huston, AD/CVD Operations, Office 6, Import...
Flight control actuation system
NASA Technical Reports Server (NTRS)
Wingett, Paul T. (Inventor); Gaines, Louie T. (Inventor); Evans, Paul S. (Inventor); Kern, James I. (Inventor)
2004-01-01
A flight control actuation system comprises a controller, electromechanical actuator and a pneumatic actuator. During normal operation, only the electromechanical actuator is needed to operate a flight control surface. When the electromechanical actuator load level exceeds 40 amps positive, the controller activates the pneumatic actuator to offset electromechanical actuator loads to assist the manipulation of flight control surfaces. The assistance from the pneumatic load assist actuator enables the use of an electromechanical actuator that is smaller in size and mass, requires less power, needs less cooling processes, achieves high output forces and adapts to electrical current variations. The flight control actuation system is adapted for aircraft, spacecraft, missiles, and other flight vehicles, especially flight vehicles that are large in size and travel at high velocities.
Flight control actuation system
NASA Technical Reports Server (NTRS)
Wingett, Paul T. (Inventor); Gaines, Louie T. (Inventor); Evans, Paul S. (Inventor); Kern, James I. (Inventor)
2006-01-01
A flight control actuation system comprises a controller, electromechanical actuator and a pneumatic actuator. During normal operation, only the electromechanical actuator is needed to operate a flight control surface. When the electromechanical actuator load level exceeds 40 amps positive, the controller activates the pneumatic actuator to offset electromechanical actuator loads to assist the manipulation of flight control surfaces. The assistance from the pneumatic load assist actuator enables the use of an electromechanical actuator that is smaller in size and mass, requires less power, needs less cooling processes, achieves high output forces and adapts to electrical current variations. The flight control actuation system is adapted for aircraft, spacecraft, missiles, and other flight vehicles, especially flight vehicles that are large in size and travel at high velocities.
Transient Analysis of Pressurization and Pneumatic Subsystems of the X-34 Main Propulsion System
NASA Technical Reports Server (NTRS)
Hedayat, A.; Knight, K. C.; Chamption, R. H., Jr.; Kennedy, Jim W. (Technical Monitor)
2000-01-01
Transient models for the pressurization, vent/relief, and pneumatic subsystems of the X-34 Main Propulsion System are presented and simulation of their operation within prescribed requirements are provided. First, using ROCket Engine Transient Simulation (ROCETS) program, pressurization subsystem operation was simulated and helium requirements and the ullage thermodynamic condition within each propellant tank were calculated. Then, Overpressurization scenarios of propellant tanks and the response of vent/relief valves were evaluated using ROCETS simulation of simultaneous operation of the pressurization and vent/relief subsystems by incorporating the valves data into the model. Finally, the ROCETS simulation of in-flight operation of pneumatic subsystem predicted the overall helium consumption, Inter-Propellant Seal (IPS) purge flowrate and thermodynamic conditions, and Spin Start power.
NASA Technical Reports Server (NTRS)
Roskam, J.; Rice, M.; Eysink, H.
1979-01-01
Mathematical models for electromechanical (EM), pneumatic and hydraulic actuations are discussed. It is shown that EM and hydraulic actuators provide better and faster time responses than pneumatic actuators but EM actuators utilizing the recently developed samarium-cobalt technology have significant advantages in terms of size, weight and power requirements. In terms of ease and flexibility of installation EM actuators apparently have several advantages over hydraulic actuators, and cost is a primary reason for the popularity of EM actuation for secondary control function since no additional systems need to be added to the aircraft. While new rare earth magnets are currently in developmental stage, costs are relatively high; but continued research should bring prices down.
Position control of an electro-pneumatic system based on PWM technique and FLC.
Najjari, Behrouz; Barakati, S Masoud; Mohammadi, Ali; Futohi, Muhammad J; Bostanian, Muhammad
2014-03-01
In this paper, modeling and PWM based control of an electro-pneumatic system, including the four 2-2 valves and a double acting cylinder are studied. Dynamic nonlinear behavior of the system, containing fast switching solenoid valves and a pneumatic cylinder, as well as electrical, magnetic, mechanical, and fluid subsystems are modeled. A DC-DC power converter is employed to improve solenoid valve performance and suppress system delay. Among different position control methods, a proportional integrator derivative (PID) controller and fuzzy logic controller (FLC) are evaluated. An experimental setup, using an AVR microcontroller is implemented. Simulation and experimental results verify the effectiveness of the proposed control strategies. Copyright © 2014 ISA. Published by Elsevier Ltd. All rights reserved.
Pain and paraesthesia produced by silicone ring and pneumatic tourniquets.
Mohan, A; Baskaradas, A; Solan, M; Magnussen, P
2011-03-01
Twenty volunteers were recruited to compare a novel, silicone ring tourniquet (the Hemaclear® tourniquet) with a pneumatic tourniquet. After application of the tourniquets, the pain and paraesthesia experienced by the participants was scored at 1 minute, 5 minutes, and 10 minutes. This was repeated with the tourniquets on the forearm. On the upper arm, the silicone ring tourniquet was associated with a significantly lower pain score than the pneumatic tourniquet. The incidence of paraesthesia was also lower with the silicone ring tourniquet. When applied to the forearm, there was no statistically significant difference in pain scores between the two types of tourniquets. However the incidence of paraesthesia was again lower with the silicone ring tourniquet.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shao, Guocheng; Lu, Donglai; Fu, Zhifeng
This paper describes the design, fabrication, and testing of a pneumatically controlled,renewable, microfluidic device for conducting bead-based assays in an automated sequential injection analysis system. The device used a “brick wall”-like pillar array (pillar size: 20 μm length X 50 μm width X 45 μm height) with 5 μm gaps between the pillars serving as the micro filter. The flow channel where bead trapping occurred is 500 μm wide X 75 μm deep. An elastomeric membrane and an air chamber were located underneath the flow channel. By applying pressure to the air chamber, the membrane is deformed and pushed upwardmore » against the filter structure. This effectively traps beads larger than 5 μm and creates a “bed” or micro column of beads that can be perfused and washed with liquid samples and reagents. Upon completion of the assay process, the pressure is released and the beads are flushed out from underneath the filter structure to renew the device. Mouse IgG was used as a model analyte to test the feasibility of using the proposed device for immunoassay applications. Resulting microbeads from an on-chip fluorescent immunoassay were individually examined using flow cytometry. The results show that the fluorescence signal intensity distribution is fairly narrow indicating high chemical reaction uniformity among the beads population. Electrochemical onchip assay was also conducted. A detection limit of 0.1 ng/mL1 ppb was achieved and good device reliability and repeatability were demonstrated. The novel microfluidic-based beadstrapping device thus opens up a new pathway to design micro-bead based biosensor immunoassays for clinical and othervarious applications.« less
Tokarz, Richard D.
1982-01-01
A liquid level sensor having a pair of upright conductors spaced by an insulator defining a first high resistance path between the conductors. An electrically conductive path is interposed between the upright conductors at a discrete location at which liquid level is to be measured. It includes a liquid accessible gap of a dimension such that the electrical resistance across the conductor when the gap is filled with the liquid is detectably less than when the gap is emptied. The conductor might also be physically altered by temperature changes to serve also as an indicator of elevated temperature.
Not Available
1981-01-29
Aliquid level sensor is described which has a pair of upright conductors spaced by an insulator defining a first high resistance path between the conductors. An electrically conductive path is interposed between the upright conductors at a discrete location at which liquid level is to be measured. It includes a liquid accessible gap of a dimension such that the electrical resistance across the conductor when the gap is filled with the liquid is detectably less than when the gap is emptied. The conductor might also be physically altered by temperature changes to serve also as an indicator of elevated temperature.
Magnetic resonance elastography using an air ball-actuator.
Numano, Tomokazu; Kawabata, Yoshihiko; Mizuhara, Kazuyuki; Washio, Toshikatsu; Nitta, Naotaka; Homma, Kazuhiro
2013-07-01
The purpose of this study was to develop a new technique for a powerful compact MR elastography (MRE) actuator based on a pneumatic ball-vibrator. This is a compact actuator that generates powerful centrifugal force vibrations via high speed revolutions of an internal ball using compressed air. This equipment is easy to handle due to its simple principles and structure. Vibration frequency and centrifugal force are freely adjustable via air pressure changes (air flow volume), and replacement of the internal ball. In order to achieve MRI compatibility, all parts were constructed from non-ferromagnetic materials. Vibration amplitudes (displacements) were measured optically by a laser displacement sensor. From a bench test of displacement, even though the vibration frequency increased, the amount of displacement did not decrease. An essential step in MRE is the generation of mechanical waves within tissue via an actuator, and MRE sequences are synchronized to several phase offsets of vibration. In this system, the phase offset was detected by a four-channel optical-fiber sensor, and it was used as an MRI trigger signal. In an agarose gel phantom experiment, this actuator was used to make an MR elastogram. This study shows that the use of a ball actuator for MRE is feasible. Copyright © 2013 Elsevier Inc. All rights reserved.
Augmenting the senses: a review on sensor-based learning support.
Schneider, Jan; Börner, Dirk; van Rosmalen, Peter; Specht, Marcus
2015-02-11
In recent years sensor components have been extending classical computer-based support systems in a variety of applications domains (sports, health, etc.). In this article we review the use of sensors for the application domain of learning. For that we analyzed 82 sensor-based prototypes exploring their learning support. To study this learning support we classified the prototypes according to the Bloom's taxonomy of learning domains and explored how they can be used to assist on the implementation of formative assessment, paying special attention to their use as feedback tools. The analysis leads to current research foci and gaps in the development of sensor-based learning support systems and concludes with a research agenda based on the findings.
Augmenting the Senses: A Review on Sensor-Based Learning Support
Schneider, Jan; Börner, Dirk; van Rosmalen, Peter; Specht, Marcus
2015-01-01
In recent years sensor components have been extending classical computer-based support systems in a variety of applications domains (sports, health, etc.). In this article we review the use of sensors for the application domain of learning. For that we analyzed 82 sensor-based prototypes exploring their learning support. To study this learning support we classified the prototypes according to the Bloom's taxonomy of learning domains and explored how they can be used to assist on the implementation of formative assessment, paying special attention to their use as feedback tools. The analysis leads to current research foci and gaps in the development of sensor-based learning support systems and concludes with a research agenda based on the findings. PMID:25679313
The application of remote sensing techniques: Technical and methodological issues
NASA Technical Reports Server (NTRS)
Polcyn, F. C.; Wagner, T. W.
1974-01-01
Capabilities and limitations of modern imaging electromagnetic sensor systems are outlined, and the products of such systems are compared with those of the traditional aerial photographic system. Focus is given to the interface between the rapidly developing remote sensing technology and the information needs of operational agencies, and communication gaps are shown to retard early adoption of the technology by these agencies. An assessment is made of the current status of imaging remote sensors and their potential for the future. Public sources of remote sensor data and several cost comparisons are included.
The VIDA Framework as an Education Tool: Leveraging Volcanology Data for Educational Purposes
NASA Astrophysics Data System (ADS)
Faied, D.; Sanchez, A.
2009-04-01
The VIDA Framework as an Education Tool: Leveraging Volcanology Data for Educational Purposes Dohy Faied, Aurora Sanchez (on behalf of SSP08 VAPOR Project Team) While numerous global initiatives exist to address the potential hazards posed by volcanic eruption events and assess impacts from a civil security viewpoint, there does not yet exist a single, unified, international system of early warning and hazard tracking for eruptions. Numerous gaps exist in the risk reduction cycle, from data collection, to data processing, and finally dissemination of salient information to relevant parties. As part of the 2008 International Space University's Space Studies Program, a detailed gap analysis of the state of volcano disaster risk reduction was undertaken, and this paper presents the principal results. This gap analysis considered current sensor technologies, data processing algorithms, and utilization of data products by various international organizations. Recommendations for strategies to minimize or eliminate certain gaps are also provided. In the effort to address the gaps, a framework evolved at system level. This framework, known as VIDA, is a tool to develop user requirements for civil security in hazardous contexts, and a candidate system concept for a detailed design phase. While the basic intention of VIDA is to support disaster risk reduction efforts, there are several methods of leveraging raw science data to support education across a wide demographic. Basic geophysical data could be used to educate school children about the characteristics of volcanoes, satellite mappings could support informed growth and development of societies in at-risk areas, and raw sensor data could contribute to a wide range of university-level research projects. Satellite maps, basic geophysical data, and raw sensor data are combined and accessible in a way that allows the relationships between these data types to be explored and used in a training environment. Such a resource naturally lends itself to research efforts in the subject but also research in operational tools, system architecture, and human/machine interaction in civil protection or emergency scenarios.
Pneumatic bracing and total contact casting have equivocal effects on plantar pressure relief.
Hartsell, H D; Fellner, C; Saltzman, C L
2001-06-01
The purpose was to examine and compare plantar pressures produced in healthy subjects while wearing a running shoe (RS), total contact cast (TCC) and 'customized' pneumatic pre-fabricated walking brace (PWB). A repeated measures design was used to compare the plantar pressures recorded for three footwear types (RS, TCC, PWB) in two body regions (forefoot, heel). Nine healthy subjects walked at a self-selected walking pace on a motorized treadmill while wearing the RS, TCC and PWB (ordered randomization). Following a five-minute acclimatization period on the treadmill with each footwear device, plantar pressures were recorded from 84 constant gait speed and step length steps using the Pedar system of in-shoe array of capacitive sensors embedded in an insert. Mean spatially averaged peak plantar pressures were recorded for the metatarsal heads and heel region for each footwear device worn by each subject. A two-way analysis of variance with repeated measures and post-hoc Tukey tests analysed the data with a significance level of p=.05. The main effects of footwear (p=.005) and body region (p=.000), and interaction effect (body region x footwear device) (p=.000) were significant. Unloading of the forefoot was 63.72% and 58.77% for the TCC and PWB, respectively, whereas loading under the heel was increased 37.09% and 34.11% for the same two devices, respectively. Patients who develop neuropathic plantar ulcers in the forefoot region, but not in the heel region, may benefit from a reduction in plantar pressures by using either the TCC or a 'customized' PWB. An alternative footwear device still needs to be found for those patients with heel ulceration.
Development of Compact, Modular Lunar Heat Flow Probes
NASA Technical Reports Server (NTRS)
Nagihara, S.; Zacny, K.; Hedlund, M.; Taylor, P. T.
2014-01-01
Geothermal heat flow measurements are a high priority for the future lunar geophysical network missions recommended by the latest Decadal Survey and previously the International Lunar Network. Because the lander for such a mission will be relatively small, the heat flow instrumentation must be a low-mass and low-power system. The instrument needs to measure both thermal gradient and thermal conductivity of the regolith penetrated. It also needs to be capable of excavating a deep enough hole (approx. 3 m) to avoid the effect of potential long-term changes of the surface thermal environment. The recently developed pneumatic excavation system can largely meet the low-power, low-mass, and the depth requirements. The system utilizes a stem which winds out of a pneumatically driven reel and pushes its conical tip into the regolith. Simultaneously, gas jets, emitted from the cone tip, loosen and blow away the soil. The thermal sensors consist of resistance temperature detectors (RTDs) embedded on the stem and an insitu thermal conductivity probe attached to the cone tip. The thermal conductivity probe consists of a short 'needle' (2.4-mm diam. and 15- to 20-mm length) that contains a platinum RTD wrapped in a coil of heater wire. During a deployment, when the penetrating cone reaches a desired depth, it stops blowing gas, and the stem pushes the needle into the yet-to-be excavated, undisturbed bottom soil. Then, it begins heating and monitors the temperature. Thermal conductivity of the soil can determined from the rate of temperature increase with time. When the measurement is complete, the system resumes excavation until it reaches the next targeted depth.
Microbioreactors with microfluidic control and a user-friendly connection to the actuator hardware
NASA Astrophysics Data System (ADS)
Buchenauer, A.; Funke, M.; Büchs, J.; Mokwa, W.; Schnakenberg, U.
2009-07-01
In this study, an array of microbioreactors based on the format of 48-well microtiter plates (MTPs) is presented. The process parameters pH and biomass are monitored online using commercially available optical sensor technology. A microfluidic device dispenses acid or base individually into each well for controlling the pH of fermentations. Fluid volumes from 72 nL to 940 nL can be supplied with valve opening times between 10 ms and 200 ms. One microfluidic device is capable of supplying four wells from two reservoirs. Up to four microfluidic devices can be integrated on the area of a prototype MTP. The devices are fabricated in polydimethylsiloxane (PDMS) using soft lithographic techniques and utilize pneumatically actuated microvalves. During fermentations, the microbioreactor is clamped to an orbital shaker and a temporary pneumatic connection guides the externally controlled pressurized air to the microfluidic device. Finally, fermentations of Escherichia coli in the presence and absence of pH control are carried out in the microbioreactor system over 18 h. During the fermentation the pH of the cultures is continuously monitored by means of optodes. An ammonia solution or phosphoric acid is dispensed to adjust the pH if it differs from the set point of 7.2. In a controlled culture, the pH can be sustained within 7.0 to 7.3 while the pH in an uncontrolled culture ranges between 6.5 and 9.0. This microbioreactor demonstrates the possibility of pH-controlled fermentations in micro-scale. The process control and the user friendly connection to the actuation hardware provide an easy handling comparable to standard MTPs.
An open-loop controlled active lung simulator for preterm infants.
Cecchini, Stefano; Schena, Emiliano; Silvestri, Sergio
2011-01-01
We describe the underlying theory, design and experimental evaluation of an electromechanical analogue infant lung to simulate spontaneous breathing patterns of preterm infants. The aim of this work is to test the possibility to obtain breathing patterns of preterm infants by taking into consideration the air compressibility. Respiratory volume function represents the actuation pattern, and pulmonary pressure and flow-rate waveforms are mathematically obtained through the application of the perfect gas and adiabatic laws. The mathematical model reduces the simulation interval into a step shorter than 1 ms, allowing to consider an entire respiratory act as composed of a large number of almost instantaneous adiabatic transformations. The device consists of a spherical chamber where the air is compressed by four cylinder-pistons, moved by stepper motors, and flows through a fluid-dynamic resistance, which also works as flow-rate sensor. Specifically designed software generates the actuators motion, based on the desired ventilation parameters, without controlling the gas pneumatic parameters with a closed-loop. The system is able to simulate tidal volumes from 3 to 8 ml, breathing frequencies from 60 to 120 bpm and functional residual capacities from 25 to 80 ml. The simulated waveforms appear very close to the measured ones. Percentage differences on the tidal volume waveform vary from 7% for the tidal volume of 3 ml, down to 2.2-3.5% for tidal volumes in the range of 4-7 ml, and 1.3% for the tidal volume equal to 8 ml in the whole breathing frequency and functional residual capacity ranges. The open-loop electromechanical simulator shows that gas compressibility can be theoretically assessed in the typical pneumatic variable range of preterm infant respiratory mechanics. Copyright © 2010 IPEM. Published by Elsevier Ltd. All rights reserved.
Frustrated total internal reflection acoustic field sensor
Kallman, Jeffrey S.
2000-01-01
A frustrated total internal reflection acoustic field sensor which allows the acquisition of the acoustic field over an entire plane, all at once. The sensor finds use in acoustic holography and acoustic diffraction tomography. For example, the sensor may be produced by a transparent plate with transparent support members tall enough to support one or more flexible membranes at an appropriate height for frustrated total internal reflection to occur. An acoustic wave causes the membrane to deflect away from its quiescent position and thus changes the amount of light that tunnels through the gap formed by the support members and into the membrane, and so changes the amount of light reflected by the membrane. The sensor(s) is illuminated by a uniform tight field, and the reflection from the sensor yields acoustic wave amplitude and phase information which can be picked up electronically or otherwise.
3D CBCT anatomy of the pterygopalatine fossa.
Rusu, Mugurel Constantin; Didilescu, Andreea Cristiana; Jianu, Adelina Maria; Păduraru, Dumitru
2013-03-01
The anatomy of the pterygopalatine fossa keeps a traditional level and is viewed as constant, even though a series of structures neighboring the fossa are known to present individual variations. We aimed to evaluate on 3D volume renderizations the anatomical variables of the pterygopalatine fossa, as related to the variable pneumatization patterns of the bones surrounding the fossa. The study was performed retrospectively on cone beam computed tomography (CBCT) scans of 100 patients. The pterygopalatine fossa was divided into an upper (orbital) and a lower (pterygomaxillary) floor; the medial compartment of the orbital floor lodges the pterygopalatine ganglion. The pneumatization patterns of the pterygopalatine fossa orbital floor walls were variable: (a) the posterior wall pneumatization pattern was determined in 89.5 % by recesses of the sphenoidal sinus related to the maxillary nerve and pterygoid canals; (b) the upper continuation of the pterygopalatine fossa with the orbital apex was narrowed in 79.5 % by ethmoid air cells and/or a maxillary recess of the sphenoidal sinus; (c) according to its pneumatization pattern, the anterior wall of the pterygopalatine fossa was a maxillary (40.5 %), maxillo-ethmoidal (46.5 %), or maxillo-sphenoidal (13 %) wall. The logistic regression models showed that the maxillo-ethmoidal type of pterygopalatine fossa anterior wall was significantly associated with a sphenoidal sinus only expanded above the pterygoid canal and a spheno-ethmoidal upper wall. The pterygopalatine fossa viewed as an intersinus space is related to variable pneumatization patterns which can be accurately identified by CBCT and 3DVR studies, for anatomic and preoperatory purposes.
NASA Astrophysics Data System (ADS)
Tomassini, R.; Rossi, G.; Brouckaert, J.-F.
2014-05-01
The accurate control of the gap between static and rotating components is vital to preserve the mechanical integrity and ensure a correct functioning of any rotating machinery. Moreover, tip leakage above the airfoil tip results in relevant aerodynamic losses. One way to measure and to monitor blade tip gaps is by the so-called Blade Tip Clearance (BTC) technique. Another fundamental phenomenon to control in the turbomachines is the vibration of the blades. For more than half a century, this has been performed by installing strain gauges on the blades and using telemetry to transmit the signals. The Blade Tip Timing (BTT) technique, (i.e. measuring the blade time of arrival from the casing at different angular locations with proximity sensors) is currently being adopted by all manufacturers as a replacement for the classical strain gauge technique because of its non-intrusive character. This paper presents a novel magnetoresistive sensor for blade tip timing and blade tip clearance systems, which offers high temporal and high spatial resolution simultaneously. The sensing element adopted is a Wheatstone bridge of Permalloy elements. The principle of the sensor is based on the variation of magnetic field at the passage of ferromagnetic objects. Two different configurations have been realized, a digital and an analogue sensor. Measurements of tip clearance have been performed in an high speed compressor and the calibration curve is reported. Measurements of blade vibration have been carried out in a dedicated calibration bench; results are presented and discussed. The magnetoresistive sensor is characterized by high repeatability, low manufacturing costs and measurement accuracy in line with the main probes used in turbomachinery testing. The novel sensor has great potential and is capable of fulfilling the requirements for a simultaneous BTC and BTT measurement system.
Murayama, Takashi; Maruyama, Ichiro N
2015-11-01
Animals can survive only within a narrow pH range. This requires continual monitoring of environmental and body-fluid pH. Although a variety of acidic pH sensor molecules have been reported, alkaline pH sensor function is not well understood. This Review describes neuronal alkaline pH sensors, grouped according to whether they monitor extracellular or intracellular alkaline pH. Extracellular sensors include the receptor-type guanylyl cyclase, the insulin receptor-related receptor, ligand-gated Cl- channels, connexin hemichannels, two-pore-domain K+ channels, and transient receptor potential (TRP) channels. Intracellular sensors include TRP channels and gap junction channels. Identification of molecular mechanisms underlying alkaline pH sensing is crucial for understanding how animals respond to environmental alkaline pH and how body-fluid pH is maintained within a narrow range. © 2015 Wiley Periodicals, Inc.
[A pneumatic generator of aerosols for group vaccination (author's transl)].
Reinet, J; Sula, E; Visnapuu, L
1978-01-01
It is given the description of a pneumatic generator of Aerosols--with the basical technical data--designed and built by the authors of this paper. The generator is used for producing aerosols for simultaneous vaccination of animals. Electrization of the aerosols contribute to a higher stability of the droplets and also to their longer retainment in the respiratory organs.