Science.gov

Sample records for pneumatic irradiation rabbit

  1. Pneumatics.

    ERIC Educational Resources Information Center

    Engelbrecht, Nancy; And Others

    This unit on pneumatics, for use in postsecondary programs, is organized in eight sections. Each section consists of information sheets with line drawings and multiple-choice questions for each topic in the sections. Answers are provided at the back of the book. The following topics are covered: (1) introduction--pressure, principles of gases,…

  2. The use of automation with the new pneumatic irradiation facility of the ORNL HFIR

    SciTech Connect

    Dyer, F.F.; Robinson, L.; Emery, J.F. )

    1988-01-01

    The High Flux Isotope Reactor at Oak Ridge National Laboratory has two pneumatic irradiation systems: PT-1 installed in 1970 and PT-2 installed in 1987, which are used for neutron activation analysis. Both systems have been described in the literature. By means of a Gould programmable controller, considerable progress has been made in a cost-effective manner to operate and automate the features of the new facility. A neutron counter is an integral part of the new pneumatic tube, and all of the hardware is present to enable automated delayed neutron counting. Some automation of the old system has also been accomplished by the use of a Zymark general purpose programmable robot. This paper describes the automated features of both systems. The reactor has been shut down for safety evaluation since November 1986, so that no irradiations have been made in the new pneumatic tube.

  3. Design and use of the ORNL HFIR (High Flux Isotope Reactor) pneumatic tube irradiation systems

    SciTech Connect

    Dyer, F.F.; Emery, J.F.; Robinson, L.; Teasley, N.A.

    1987-01-01

    A second pneumatic tube that was recently installed in the High Flux Isotope Reactor for neutron activation analysis is described. Although not yet tested, the system is expected to have a thermal neutron flux of about 1.5 x 10/sup 14/ cm/sup -2/ s/sup -1/. A delayed neutron counter is an integral part of the pneumatic tube, and all of the hardware is present to enable automated use of the counter. The system is operated with a Gould programmable controller that is programmed with an IBM personal computer. Automation of any mode of operation, including the delayed neutron counter, will only require a nominal amount of software development. Except for the lack of a hot cell, the irradiation facility has all of the advantageous features of an older pneumatic tube that has been in operation for 17 years. The design of the system and some applications and methods of operation are described.

  4. Phase separation of X-irradiated lenses of rabbit

    SciTech Connect

    Clark, J.I.; Giblin, F.J.; Reddy, V.N.; Benedek, G.B.

    1982-02-01

    The phase separation temperature (Tcat) was studied as a function of time (age) after the administration of a single dose of radiation (2000 rad), which induces cataract in the rabbit lens. In the normal unirradiated lens, Tcat decreases linearly with age at a rate (DTcat/dt) approximately 2.2 degrees/week. In the irradiated lens, Tcat initially decreases with age much less than the normal lens, then rises sharply with age at the time of the appearance of opacity in the living rabbit eye. We suggest that the phase separation temperature may serve as a sensitive and early indicator of cataractogenic processes in the lens.

  5. Late degeneration in rabbit tissues after irradiation by heavy ions

    NASA Technical Reports Server (NTRS)

    Lett, J. T.; Cox, A. B.; Keng, P. C.; Lee, A. C.; Su, C. M.; Bergtold, D. S.

    1980-01-01

    Results are presented for investigations of the late effects of heavy-ion irradiation on rabbit tissues which were undertaken to assess the hazards associated with the long-term exposure of humans to heavy ions in space during such activities as the construction of solar power stations or voyages to Mars. White rabbits approximately six weeks old were exposed to various doses of collimated beams of 400-MeV/n Ne ions, 570 MeV/n Ar ions and Co-60 gamma rays directed through both eyes, and the responses of the various tissues (hair follicles, skin, cornea, lens, retina, Harderian glands, bone and forebrain) were examined. Proliferating tissues are found to exhibit high damage levels in the early and late periods following irradiation, while terminally differentiating tissues repond to radiation most intensely in the late period, years after irradiation, with no intermediate recovery. The results obtained from rabbits are used to predict the occurrence of late tissue degeneration in the central nervous system, terminally differentiating systems and stem cells of humans one or more decades following exposure to radiation levels anticipated during long-duration space flights. The studies also indicate that tissues may be prematurely aged in the sense that tissue life spans may be shortened without the development of malignancies.

  6. Disposal rabbit

    DOEpatents

    Lewis, L.C.; Trammell, D.R.

    1983-10-12

    A disposable rabbit for transferring radioactive samples in a pneumatic transfer system comprises aerated plastic shaped in such a manner as to hold a radioactive sample and aerated such that dissolution of the rabbit in a solvent followed by evaporation of the solid yields solid waste material having a volume significantly smaller than the original volume of the rabbit.

  7. Disposable rabbit

    DOEpatents

    Lewis, Leroy C.; Trammell, David R.

    1986-01-01

    A disposable rabbit for transferring radioactive samples in a pneumatic transfer system comprises aerated plastic shaped in such a manner as to hold a radioactive sample and aerated such that dissolution of the rabbit in a solvent followed by evaporation of the solid yields solid waste material having a volume significantly smaller than the original volume of the rabbit.

  8. Effects of pre- and postoperative irradiation on the healing of bone grafts in the rabbit

    SciTech Connect

    Morales, M.J.; Marx, R.E.; Gottlieb, C.F.

    1987-01-01

    Healing of cellular bone grafts irradiated at various times in the postsurgical course was compared to the healing characteristics of bone grafts placed into already irradiated tissue and to controls of irradiated host mandible in a rabbit model. Physical graft consolidation was assessed by load stress characteristics and serial histologic examination. Results indicated that grafts placed into already irradiated tissues failed to form bone in both phases of expected regeneration resulting in structurally weakened and histologically deficient ossicles. Bone grafts irradiated after placement were tolerant of irradiation. Bone grafts irradiated after four weeks were found to be less affected by irradiation than those irradiated within the first four weeks, forming an ossicle structurally and histologically superior to that of bone ossicles developed from grafts placed into irradiated tissues.

  9. Apraclonidine effects on ocular responses to YAG laser irradiation to the rabbit iris

    SciTech Connect

    Sugiyama, K.; Kitazawa, Y.; Kawai, K. )

    1990-04-01

    Apraclonidine (p-aminoclonidine) ophthalmic solution effectively reduces the rise in intraocular pressure (IOP) following anterior segment laser surgery. We tested the effect of topical 0.5% apraclonidine on intraocular pressure and on protein and prostaglandin (PG) E2 concentrations in aqueous humor following Q-switched Nd:YAG laser irradiation to the iris of albino rabbits, at an energy level of 2 to 200 mJ. IOP was measured prior to and for 24 hr after irradiation. Aqueous humor was withdrawn before and 1 hr after laser irradiation for determining protein (Lowry method) and PGE2 (radioimmunoassay). Four to seven rabbits were used for each experiment. The increase in IOP and protein concentration following laser irradiation was demonstrated to be dependent on the amount of laser energy. Apraclonidine completely abolished the IOP rise, and significantly reduced the elevation of protein content. Apraclonidine failed to affect the increase in PGE2.

  10. Gamma-Irradiated Sterile Cornea for Use in Corneal Transplants in a Rabbit Model

    PubMed Central

    Yoshida, Junko; Heflin, Thomas; Zambrano, Andrea; Pan, Qing; Meng, Huan; Wang, Jiangxia; Stark, Walter J.; Daoud, Yassine J.

    2015-01-01

    Purpose: Gamma irradiated corneas in which the donor keratocytes and endothelial cells are eliminated are effective as corneal lamellar and glaucoma patch grafts. In addition, gamma irradiation causes collagen cross inking, which stiffens collagen fibrils. This study evaluated gamma irradiated corneas for use in corneal transplantations in a rabbit model comparing graft clarity, corneal neovascularization, and edema. Methods: Penetrating keratoplasty was performed on rabbits using four types of corneal grafts: Fresh cornea with endothelium, gamma irradiated cornea, cryopreserved cornea, and fresh cornea without endothelium. Slit lamp examination was performed at postoperative week (POW) one, two, and four. Corneal clarity, edema, and vascularization were graded. Confocal microscopy and histopathological evaluation were performed. A P < 0.05 was statistically significant. Results: For all postoperative examinations, the corneal clarity and edema were statistically significantly better in eyes that received fresh cornea with endothelium compared to the other three groups (P < 0.05). At POW 1, gamma irradiated cornea scored better than the cryopreserved and fresh cornea without endothelium groups in clarity (0.9 vs. 1.5 and 2.6, respectively), and edema (0.6 vs. 0.8 and 2.0, respectively). The gamma irradiated corneas, cryopreserved corneas and the fresh corneas without endothelium, developed haze and edema after POW 2. Gamma irradiated cornea remained statistically significantly clearer than cryopreserved and fresh cornea without endothelium during the observation period (P < 0.05). Histopathology indicated an absence of keratocytes in gamma irradiated cornea. Conclusion: Gamma irradiated corneas remained clearer and thinner than the cryopreserved cornea and fresh cornea without endothelium. However, this outcome is transient. Gamma irradiated corneas are useful for lamellar and patch grafts, but cannot be used for penetrating keratoplasty. PMID:26180475

  11. Effect of low-power helium-neon laser irradiation on 13-week immobilized articular cartilage of rabbits.

    PubMed

    Bayat, Mohammad; Ansari, Anayatallah; Hekmat, Hossien

    2004-09-01

    Influence of low-power (632.8 nm, Helium-Neon, 13 J/cm2, three times a week) laser on 13-week immobilized articular cartilage was examined with rabbits knee model. Number of chondrocytes and depth of articular cartilage of experimental group were significantly higher than those of sham irradiated group. Surface morphology of sham-irradiated group had rough prominences, fibrillation and lacunae but surface morphology of experimental group had more similarities to control group than to sham irradiated group. There were marked differences between ultrastructure features of control group and experimental group in comparison with sham irradiated group. Low-power Helium-Neon laser irradiation on 13-week immobilized knee joints of rabbits neutrilized adverse effects of immobilization on articular cartilage.

  12. Bioeffect of lipohemia rabbits irradiated in oral mucosa with 650-nm diode-laser-accompanied oxygen inspiration and clinical application

    NASA Astrophysics Data System (ADS)

    Yang, Fu-Shou; Tang, Jin-Xian; Liu, Cheng; Yang, Xi-Cheng; Pang, Hi-Xiu

    1998-11-01

    The study on irradiating in oral mucosa of rabbits with 650 nm diode laser and clinical application has been reported in this paper. The result of animal experiment showed: the obvious decrease of cholesterin and triglyceride has been found among those highly lipohemia rabbits in the experiments of 650nm diode laser irradiating accompanying with oxygen, as well as the parameters of hemorheology obviously being improved, as compared with highly lipohemia rabbits un-irradiating, the statistical analysis showing P < 0.01. In the meantime, the observation of histopathology shows, the lipide decreasing in aorta wall, intramyocardinal membranous layer,and renal interstitial in the group of rabbits which are irradiated with laser and accompanying with oxygen inspiration, and even the perfectly recovered tissue in some rabbits has been seen. This experimental result is significantly for clinical application. The results of clinic application showed, that the patients employed this method which treatment cerebral infarction, lipohemia, the total effective ratio achieved 91.7 percent, perfect effect 30.6 percent.

  13. Effect of helium-neon and infrared laser irradiation on wound healing in rabbits

    SciTech Connect

    Braverman, B.; McCarthy, R.J.; Ivankovich, A.D.; Forde, D.E.; Overfield, M.; Bapna, M.S.

    1989-01-01

    We examined the biostimulating effects of helium-neon laser radiation (HeNe; 632.8 nm), pulsed infrared laser radiation (IR; 904 nm), and the two combined on skin wound healing in New Zealand white rabbits. Seventy-two rabbits received either (1) no exposure, (2) 1.65 J/cm2 HeNe, (3) 8.25 J/cm2 pulsed IR, or (4) both HeNe and IR together to one of two dorsal full-thickness skin wounds, daily, for 21 days. Wound areas were measured photographically at periodic intervals. Tissue samples were analyzed for tensile strength, and histology was done to measure epidermal thickness and cross-sectional collagen area. Significant differences were found in the tensile strength of all laser-treated groups (both the irradiated and nonirradiated lesion) compared to group 1. No differences were found in the rate of wound healing or collagen area. Epidermal growth was greater in the HeNe-lased area compared to unexposed tissue, but the difference was not significant. Thus, laser irradiation at 632.8 nm and 904 nm alone or in combination increased tensile strength during wound healing and may have released tissue factors into the systemic circulation that increased tensile strength on the opposite side as well.

  14. The hematologic effects of low intensity 650 nm laser irradiation on hypercholesterolemia rabbits

    PubMed Central

    Wang, Hong; Deng, Juan; Tu, Wenjun; Zhang, Lin; Chen, Hongli; Wu, Xiaoguang; Li, Yingxin; Sha, Hong

    2016-01-01

    Purpose: To test the hematologic effects of low intensity 650 nm laser irradiation on hypercholesterolemia rabbits. Methods: Ten male big-eared rabbits were selected from hypercholesterolemia animal model-making and divided into model group and laser treatment groups. Five normal rabbits were selected as control group. Auricle root irradiation of 650 nm laser 100 mW in 30 min were applied on treatment group twice a day, treatment of 6 days in one week, 20 weeks course of treatment. Changes in blood lipid, microcirculation, rheological properties, and aggregation morphology of erythrocytes were observed every two weeks. Histopathological examination were performed in the end of experiments. Results: After 20 weeks’ treatment, triglyceride (TG), cholesterol (CHO), high density lipoprotein (HDL) and low density lipoprotein (LDL) of serum in hypercholesterolemia groups showed less changes in the first 4 weeks, butdifferent decreasing trends were shownin the next 16 weeks’ therapy. Erythrocytes aggregation of model groups showed rouleau state, while red blood cells in control group showed fine homodisperse, erythrocytes in treatment group performed better dispersion than model groups. Erythrocyte deformation index (DI) and blood flow value showed a statistic improvement in treatment group than control and model group (P<0.01). Value of DI in treatment group decreased after 18 weeks than values before therapy (P<0.01). Varying degrees of Aorta plaque formation was observed for individual difference in model and treatment groups, while no plaque was found in control group. Conclusions: Low energy laser improve microcirculation, rheological properties and blood lipid that might be related with erythrocytes aggregation and deformability. PMID:27347336

  15. The irradiation of rabbit sperm cells with He-Ne laser prevents their in vitro liquid storage dependent damage.

    PubMed

    Iaffaldano, Nicolaia; Rosato, Maria Pina; Paventi, Gianluca; Pizzuto, Roberto; Gambacorta, Mario; Manchisi, Angelo; Passarella, Salvatore

    2010-05-01

    The aim of the study was to investigate the effects of different energy doses of helium-neon (He-Ne) laser irradiation on both mitochondrial bioenergetics functions and functional quality of rabbit spermatozoa during 48 h of in vitro liquid storage at 15 degrees C. 11 rabbit semen pools were each divided into four aliquots: three of them were irradiated with He-Ne laser with different energy doses (3.96, 6.12 and 9.00 J/cm(2)) being the last control kept under the same experimental conditions without irradiation. Sperm motility, viability and acrosome integrity were monitored together with cytochrome c oxidase (COX) activity and the cell energy charge (EC) at 0, 24 and 48 h of storage. Irradiated samples stored for 24 and 48 h better maintained motility (P < 0.01), acrosome integrity (P < 0.01) and viability (P < 0.05) with respect to the control, particularly with the energy dose of 6.12 J/cm(2) that showed the most intense biostimulative effect. COX activity and EC were immediately increased by irradiation particularly in the treatments 6.12 and 9.00 J/cm(2) (P < 0.05), that maintained their levels higher with respect to the control after 48 h of storage (P < 0.01). COX activity of rabbit sperm cells was positively correlated with EC (P < 0.05), viability (P < 0.01) and acrosome integrity (P < 0.05) parameters. These results indicate that the effects of He-Ne laser irradiation on sperm cells are mediated through the stimulation of the sperm mitochondrial respiratory chain and that this effect plays a significant role in the augmentation of the rabbit sperm cells' capability to survive during liquid storage conditions. PMID:19932573

  16. A Rabbit Irradiation Platform for Outcome Assessment of Lung Stereotactic Radiosurgery

    SciTech Connect

    Cai Jing; Mata, Jaime F.; Orton, Matthew D.; Hagspiel, Klaus D.; Mugler, John P.; Larner, James M.; Sheng Ke; Read, Paul W.

    2009-04-01

    Purpose: To evaluate a helical tomotherapy-based rodent radiosurgery platform that reproduces human image-guided radiosurgery treatment to study radiobiologic effects of stereotactic radiosurgery on lung tissues using functional magnetic resonance imaging (MRI). Methods and Materials: Hypofractionated radisourgery (20 Gy x 3) was delivered to the right lung of three New Zealand rabbits using Helical TomoTherapy with MVCT image guidance. Contrast-enhanced MR perfusion, hyperpolarized helium-3 MR ventilation, and CT were obtained before radiation and monthly for 4 months after radiation. All MRI was performed on a 1.5-T whole-body scanner with broad-band capabilities. Results: Precise dose delivery to 1.6 cc of the lower right lung was achieved without additional immobilization. No deficits were detected at baseline with respect to perfusion and ventilation. Lung perfusion deficits in the irradiated lung regions began at 2 months after radiation and worsened with time. No ventilation deficits were observed after radiation. Decrease in lung CT density in irradiated regions was observed after radiation, but the changes were less significant than those in perfusion MRI. Conclusions: We demonstrated that highly conformal radiation can be reproducibly delivered to a small volume of rodent lung on a widely available clinical unit. The radiation-induced lung injury can be detected as early as 2 months after radiation with perfusion MRI. The primary pattern of injury agrees with previously reported endothelial damage to radiosurgical radiation doses. This experimental design provides a cost-effective methodology for producing radiosurgical injuries in rodents that reproduces current human treatments for studying radiation injury and agents that might affect it.

  17. Investigation of carbohydrate and protein metabolism in the digestive organs of the rabbit under the combined influence of vibration, acceleration and irradiation

    NASA Technical Reports Server (NTRS)

    Yuy, R. I.

    1975-01-01

    During spaceflight, the organism is subjected to the influence of various extremal factors such as acceleration, vibration, irradiation, etc. The study of the influence of these factors on metabolism, especially carbohydrate and protein metabolism, in young rabbits is of great significance in simulation experiments. Dynamic factors and irradiation, depending on dose and duration, lead to reduced RNA and protein metabolism.

  18. Differential analysis of D-{beta}-Asp-containing proteins found in normal and infrared irradiated rabbit lens

    SciTech Connect

    Takata, Takumi; Shimo-Oka, Tadashi; Kojima, Masami; Miki, Kunio; Fujii, Noriko . E-mail: nfujii@HL.rri.kyoto-u.ac.jp

    2006-05-26

    Although proteins are generally composed of L-{alpha}-amino acids, D-{beta}-aspartic acid (Asp)-containing proteins have been reported in various elderly tissues. Our previous study detected several D-{beta}-Asp-containing proteins in a rabbit lens derived from epithelial cell line by Western blot analysis of a 2D-gel using a polyclonal antibody that is highly specific for D-{beta}-Asp-containing proteins. The identity of each spot was subsequently determined by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry and the Ms-Fit online database searching algorithm. In this study, we discovered novel D-{beta}-Asp-containing proteins from rabbit lens. The results indicate that {beta}-crystallin A3, {beta}-crystallin A4, {beta}-crystallin B1, {beta}-crystallin B2, {beta}-crystallin B3, {gamma}-crystallin C, {gamma}-crystallin D, and {lambda}-crystallin in rabbit lens contain D-{beta}-Asp residues. Furthermore, the occurrence of D-{beta}-Asp residues increases with infrared ray (IR) irradiation. Additionally, some D-{beta}-Asp-containing proteins only appear after IR irradiation. One such protein is the {alpha}-enolase, which shows homology to {tau}-crystallin.

  19. The effect of topical dexamethasone and preoperative beta irradiation on a model of glaucoma fistulizing surgery in the rabbit

    SciTech Connect

    Miller, M.H.; Grierson, I.; Unger, W.G.; Hitchings, R.A. )

    1990-01-01

    We studied the effect of topical dexamethasone (1%) and preoperative beta irradiation on a model of glaucoma fistulizing surgery in the rabbit. Intraocular pressure and gross facility of aqueous outflow following surgery were not influenced by either treatment, although blebs persisted longer in the irradiated eyes. Steroids reduced clinically observable inflammation as well as the number of inflammatory cells identifiable by microscopy. Fibroblast production temporarily slowed, and ultrastructural examination demonstrated lipid-filled vacuoles and dilated mitochondria in these eyes. Also, the scar was thinner at 24 days. Beta irradiation delayed wound healing and the scar was thinner in the early postoperative stages, but the light microscopic appearance of the scar was unaltered at 59 days. Inflammation was more pronounced initially, with abundant fibrin in the wound. Recovery of the conjunctival epithelium was delayed. The delay in fibroblast recruitment and wound contraction, the thinner scar tissue, and the increased survival of the bleb are all factors that suggest that beta irradiation may be a useful adjunct to glaucoma surgery.

  20. Basic Pneumatics. Instructor's Guide.

    ERIC Educational Resources Information Center

    Fessehaye, Michael

    This instructor's guide is designed for use by industrial vocational teachers in teaching a course on basic pneumatics. Covered in the individual units are the following topics: an introduction to pneumatics (including the operation of a service station hoist); fundamentals and physical laws; air compressors (positive displacement compressors;…

  1. Pneumatic freight pipelines

    SciTech Connect

    Weaver, P.B.

    1994-12-31

    There is a great deal of technology and experience in and from the Pneumatic Tube System industry that must be tapped because it is directly and/or indirectly applicable to the Pneumatic Freight Pipeline industry. Otherwise a great deal of time will be spent re-inventing the wheel.

  2. Rotary pneumatic valve

    DOEpatents

    Hardee, Harry C.

    1991-01-01

    A rotary pneumatic valve which is thrust balanced and the pneumatic pressure developed produces only radial loads on the valve cylinder producing negligible resistance and thus minimal torque on the bearings of the valve. The valve is multiplexed such that at least two complete switching cycles occur for each revolution of the cylinder spindle.

  3. Converging Stereotactic Radiotherapy Using Kilovoltage X-Rays: Experimental Irradiation of Normal Rabbit Lung and Dose-Volume Analysis With Monte Carlo Simulation

    SciTech Connect

    Kawase, Takatsugu; Kunieda, Etsuo Deloar, Hossain M.; Tsunoo, Takanori; Seki, Satoshi; Oku, Yohei; Saitoh, Hidetoshi; Saito, Kimiaki; Ogawa, Eileen N.; Ishizaka, Akitoshi; Kameyama, Kaori; Kubo, Atsushi

    2009-10-01

    Purpose: To validate the feasibility of developing a radiotherapy unit with kilovoltage X-rays through actual irradiation of live rabbit lungs, and to explore the practical issues anticipated in future clinical application to humans through Monte Carlo dose simulation. Methods and Materials: A converging stereotactic irradiation unit was developed, consisting of a modified diagnostic computed tomography (CT) scanner. A tiny cylindrical volume in 13 normal rabbit lungs was individually irradiated with single fractional absorbed doses of 15, 30, 45, and 60 Gy. Observational CT scanning of the whole lung was performed every 2 weeks for 30 weeks after irradiation. After 30 weeks, histopathologic specimens of the lungs were examined. Dose distribution was simulated using the Monte Carlo method, and dose-volume histograms were calculated according to the data. A trial estimation of the effect of respiratory movement on dose distribution was made. Results: A localized hypodense change and subsequent reticular opacity around the planning target volume (PTV) were observed in CT images of rabbit lungs. Dose-volume histograms of the PTVs and organs at risk showed a focused dose distribution to the target and sufficient dose lowering in the organs at risk. Our estimate of the dose distribution, taking respiratory movement into account, revealed dose reduction in the PTV. Conclusions: A converging stereotactic irradiation unit using kilovoltage X-rays was able to generate a focused radiobiologic reaction in rabbit lungs. Dose-volume histogram analysis and estimated sagittal dose distribution, considering respiratory movement, clarified the characteristics of the irradiation received from this type of unit.

  4. Improvement of thermal effects to rabbit atherosclerotic aortas by macro pulse irradiation of a quantum cascade laser in the 5.7 μm wavelength range

    NASA Astrophysics Data System (ADS)

    Hashimura, Keisuke; Ishii, Katsunori; Awazu, Kunio

    2015-03-01

    Atherosclerotic plaques mainly consist of cholesteryl esters. Cholesteryl esters have an absorption peak at the wavelength of 5.75 μm originated from C=O stretching vibration mode of ester bond. Our group achieved making cutting difference between atherosclerotic lesions and normal vessels using a quantum cascade laser (QCL) in the 5.7 μm wavelength range. QCLs are relatively new types of semiconductor lasers that can emit mid-infrared range. They are sufficiently compact and have recently achieved their high-power emission. However, large thermal damage was observed because the QCL worked as a quasi-continuous wave laser due to its short pulse interval. To realize less invasive ablation by the QCL, reducing thermal effects to normal vessels is needed. In this study, we tried improving the thermal effects by changing the pulse structure. First, irradiation effects to rabbit atherosclerotic aortas by macro pulse irradiation (irradiation of pulses at intervals) and conventional continuous pulse irradiation were compared. The macro pulse width and the macro pulse interval were set to 0.54 and 12 ms, respectively, because the thermal relaxation time of rabbit normal and atherosclerotic aortas in the oscillation wavelength was 0.54-12 ms. As a result, ablation depth became longer and coagulation width became shorter by the macro pulse irradiation. In addition, cutting difference between rabbit normal and atherosclerotic aortas was observed by the macro pulse irradiation. Therefore, the macro pulse irradiation achieved the improvement of thermal effects by the QCL in the 5.7 μm wavelength range. The QCL has the potential of realizing less-invasive laser angioplasty.

  5. Topical Administration of the Mitochondrial PTP Opening Inhibitor CoQ10 Prevents Apoptotic Cell Death Induced by UVC-Irradiation in Rat's Corneas and Rabbit's Retinas

    NASA Astrophysics Data System (ADS)

    Papucci, Laura; Witort, Ewa; Schiavone, Nicola; Donnini, Martino; Lapucci, Andrea; Lulli, Matteo; Lazzarano, Stefano; Simoncini, Madine; Mazzoni, Tiziano; Falciani, Piergiuseppe; Capaccioli, Sergio

    2008-06-01

    We have previously demonstrated in vitro that ubiquitous free radical scavenger coenzyme Q10 prevents keratocyte apoptosis induced by excimer laser irradiation more efficiently than other antioxidants. We showed that its anti apoptotic property is independent of its free radical scavenging ability and is related to direct inhibition of PTP (permeability transition pore) opening and mitochondrial depolarization. Here, we demonstrate in vivo, that CoQ10 can efficiently protect rat's corneas and rabbit's retinas irradiated with UVC. Therefore, we propose application of CoQ10 as countermeasure to prevent micro radiation-induced eye damage during interplanetary space exploration.

  6. The effect of 10 and 20 Gy single dose irradiation on the esophageal mucosa of the rabbit. An electron microscopic study

    SciTech Connect

    Hakansson, C.H.; Albertsson, M.; Palmegren, M. )

    1989-12-01

    The mucosa of rabbit esophagus was irradiated with single doses of 10 and 20 Gy respectively. Specimens were taken for scanning electron microscopy (SEM), and light microscopy investigations. Examinations were made 1-14 days after 10 Gy and 1-17 days after 20 Gy. Irradiation resulted in edema during the first days. The thickness of the epithelium was at its lowest value around day 5 after the administration of 10 Gy, and on days eight to ten after the administration of 20 Gy. Damage of the epithelium surface, as scored on SEM micrographs, was most pronounced on days eight to eleven after irradiation, showing a clear dose dependency. The second week after irradiation repair was seen concluding in an overshoot of the mucosal height. The amount of bacteria on the surface increased during the period of edema, and decreased when the damage was most pronounced.

  7. Effect of low-level laser therapy irradiation and Bio-Oss graft material on the osteogenesis process in rabbit calvarium defects: a double blind experimental study.

    PubMed

    Rasouli Ghahroudi, Amir Alireza; Rokn, Amir Reza; Kalhori, Katayoun A M; Khorsand, Afshin; Pournabi, Alireza; Pinheiro, A L B; Fekrazad, Reza

    2014-05-01

    This study aims to assess the effect of low-level laser therapy (LLLT) irradiation and Bio-Oss graft material on the osteogenesis process in the rabbit calvarium defects. Twelve white male New Zealand rabbits were included in this study. Four 8-mm diameter identical defects were prepared on each rabbit's calvarium. One site was left as an untreated control (C), the second site was filled with Bio-Oss (B), the third site was treated with laser irradiation (L), and the fourth site treated with Bio-Oss and laser irradiation (B + L). In the laser group, a diode laser (wavelength 810 nm, output power 300 mW, irradiation mode CW, energy density 4 J/cm2) was applied immediately after surgery and then one other day for the next 20 days. After 4 and 8 weeks, the animals were sacrificed and histological and histomorphometric examinations were performed and the data were subjected to Friedman and repeated measurements ANOVA tests. Significant differences were not found regarding inflammation severity, foreign body reactions, and vitality of newly formed bone on 4th and 8th week after operation. The mean amount of new bone was 15.83 and 18.5% in the controls on the 4th and 8th week; 27.66 and 25.16% in the laser-irradiated group; 35.0 and 41.83% in Bio-Oss and 41.83 and 47.0% in the laser + Bio-Oss treated specimens with significant statistical differences (p <0.05). Application of LLLT in combination with Bio-Oss® can promote bone healing. Therefore, LLLT may be clinically beneficial in promoting bone formation in skeletal defects.

  8. Pneumatic soil removal tool

    DOEpatents

    Neuhaus, J.E.

    1992-10-13

    A soil removal tool is provided for removing radioactive soil, rock and other debris from the bottom of an excavation, while permitting the operator to be located outside of a containment for that excavation. The tool includes a fixed jaw, secured to one end of an elongate pipe, which cooperates with a movable jaw pivotably mounted on the pipe. Movement of the movable jaw is controlled by a pneumatic cylinder mounted on the pipe. The actuator rod of the pneumatic cylinder is connected to a collar which is slidably mounted on the pipe and forms part of the pivotable mounting assembly for the movable jaw. Air is supplied to the pneumatic cylinder through a handle connected to the pipe, under the control of an actuator valve mounted on the handle, to provide movement of the movable jaw. 3 figs.

  9. Pneumatic soil removal tool

    DOEpatents

    Neuhaus, John E.

    1992-01-01

    A soil removal tool is provided for removing radioactive soil, rock and other debris from the bottom of an excavation, while permitting the operator to be located outside of a containment for that excavation. The tool includes a fixed jaw, secured to one end of an elongate pipe, which cooperates with a movable jaw pivotably mounted on the pipe. Movement of the movable jaw is controlled by a pneumatic cylinder mounted on the pipe. The actuator rod of the pneumatic cylinder is connected to a collar which is slidably mounted on the pipe and forms part of the pivotable mounting assembly for the movable jaw. Air is supplied to the pneumatic cylinder through a handle connected to the pipe, under the control of an actuator valve mounted on the handle, to provide movement of the movable jaw.

  10. Pneumatic sample-transfer system for use with the Lawrence Livermore National Laboratory rotating target neutron source (RTNS-I)

    SciTech Connect

    Williams, R.E.

    1981-07-01

    A pneumatic sample-transfer system is needed to be able to rapidly retrieve samples irradiated with 14-MeV neutrons at the Rotating Target Neutron Source (RTNS-I). The rabbit system, already in place for many years, has been refurbished with modern system components controlled by an LSI-11 minicomputer. Samples can now be counted three seconds after an irradiation. There are many uses for this expanded 14-MeV neutron activation capability. Several fission products difficult to isolate from mixed fission fragments can be produced instead through (n,p) or (n,..cap alpha..) reactions with stable isotopes. Mass-separated samples of Nd, Mo, and Se, for example, can be irradiated to produce Pr, Nb, and As radionuclides sufficient for decay scheme studies. The system may also be used for multielement fast-neutron activation analysis because the neutron flux is greater than 2 x 10/sup 11/ n/cm/sup 2/-sec. Single element analyses of Si and O are also possible. Finally, measurements of fast-neutron cross sections producing short-lived activation products can be performed with this system. A description of the rabbit system and instructions for its use are presented in this report.

  11. Ultraviolet-irradiated vaccinia virus recombinants, exposing HIV-envelope on their outer membrane, induce antibodies against this antigen in rabbits.

    PubMed

    Loewinger, M; Katz, E

    2002-01-01

    The construction and isolation of recombinants of vaccinia virus (IHD-J strain), bearing on their outer membrane a chimeric protein consisting of the cytoplasmic and transmembrane domains of vaccinia B5R protein and the external domain of HIV envelope, has been previously described by us. The present study aimed to investigate the potential use of such recombinants as a vaccine, following inactivation of their infectivity by ultraviolet (UV) irradiation. The minimal dose of UV irradiation, required for the complete inactivation of the infectivity of these recombinants, was determined. Injections of rabbits with the irradiated noninfectious recombinant viruses successfully induced specific antibodies against the HIV envelope antigen, in addition to those against the poxvirus. PMID:12479396

  12. The influence of intravenous laser irradiation of blood on some metabolic and functional parameters in intact rabbits and experimental cerebral ischaemia

    NASA Astrophysics Data System (ADS)

    Nechipurenko, N.; Vasilevskaya, L.; Musienko, J.; Maslova, G.

    2007-07-01

    It has been studied the intravenous laser irradiation of blood (ILIB) influence with helium-neon laser (HNL) of 630 nm wavelength on some of lipid peroxidation (LPO) and antioxidant system (AOS) findings, aside-base status (ABS) and blood oxygen transport (BOT), state of dermal microhaemodynamics (MGD) in the intact rabbits and after modeling of local ischemia of brain (LIB). Depending on conditions of organism functioning (norm or brain ischaemia) ILIB has resulted in stimulating or normalizing effects on the whole metabolic and microhaemocirculation processes which had been studied during our investigation. It is discussed the mechanisms of pathogenetic directivity of ILIB influence in cerebral ischaemia

  13. Combination of BMP-2-releasing gelatin/β-TCP sponges with autologous bone marrow for bone regeneration of X-ray-irradiated rabbit ulnar defects.

    PubMed

    Yamamoto, Masaya; Hokugo, Akishige; Takahashi, Yoshitake; Nakano, Takayoshi; Hiraoka, Masahiro; Tabata, Yasuhiko

    2015-07-01

    The objective of this study is to evaluate the feasibility of gelatin sponges incorporating β-tricalcium phosphate (β-TCP) granules (gelatin/β-TCP sponges) to enhance bone regeneration at a segmental ulnar defect of rabbits with X-ray irradiation. After X-ray irradiation of the ulnar bone, segmental critical-sized defects of 20-mm length were created, and bone morphogenetic protein-2 (BMP-2)-releasing gelatin/β-TCP sponges with or without autologous bone marrow were applied to the defects to evaluate bone regeneration. Both gelatin/β-TCP sponges containing autologous bone marrow and BMP-2-releasing sponges enhanced bone regeneration at the ulna defect to a significantly greater extent than the empty sponges (control). However, in the X-ray-irradiated bone, the bone regeneration either by autologous bone marrow or BMP-2 was inhibited. When combined with autologous bone marrow, the BMP-2 exhibited significantly high osteoinductivity, irrespective of the X-ray irradiation. The bone mineral content at the ulna defect was similar to that of the intact bone. It is concluded that the combination of bone marrow with the BMP-2-releasing gelatin/β-TCP sponge is a promising technique to induce bone regeneration at segmental bone defects after X-ray irradiation.

  14. Influence of intravascular low level He-Ne laser irradiation on iNOS, total-NOS, and ET-1 in acute spinal cord-injured rabbits

    NASA Astrophysics Data System (ADS)

    Yin, Zhenchun; Dong, Yinghai; Zhu, Jing

    2005-07-01

    Objective To research the influence of intravascular low level Laser irradiation (ILLLI) on total NOS, iNOS, and ET-1 in spinal cord following acute spinal cord injury (ASCI), and discuss the protective effects of ILLLI on neurons .Methods 72 rabbits were randomly divided into 3 groups: treatment group, injury group and control group. In treatment group and injury group, after laminectomy at the level of T-13, ASCI was performed by using Allen"s method with slight modification (6g×10cm) on rabbits. After injury, rabbits were treated immediately with He-Ne laser (power 5 mW, 1 hour per day for 10 days). At the day of 10th after treatment, total-NOS, iNOS, and ET-1 in spinal cord tissues were measured. Results The expression level of total-NOS, iNOS, and ET-1 in spinal cord in injury group were significantly higher than those in control group (P<0.05), while after ILLLI the level of these index in treatment group decreased statistically significantly compared with those in injury group (P<0.05). Conclusion ILLLI can significantly decrease the expression level of total-NOS, iNOS, and ET-1 in spinal cord. It indicates that ILLLI can relieve the overexpression of total-NOS, iNOS, and ET-1 ,and thus can perform protective effects on neurons in the course of secondary spinal cord injury (SSCI) following ASCI

  15. Induction of skin papillomas in the rabbit, Oryctologus cuniculus, by bites of a blood-sucking insect, Cimex lectularius, irradiated by gamma rays.

    PubMed

    el-Mofty, M M; Sakr, S A; Younis, M W

    1989-11-01

    Bed bugs, Cimex lectularius, irradiated with gamma rays were allowed to suck blood from shaved areas of the skin of rabbits, Oryctolagus cuniculus, 2 times/week for 5 months and then once weekly for another 5 months. This significantly induced the formation of skin papillomas and sweat gland hyperplasia in five out of nine experimental animals. It is speculated that the saliva of the irradiated bugs was activated by gamma rays and was responsible for the induction of skin papillomas. Because bed bugs play a significant role in the transmission of virus, it is also speculated that there is a virus in the saliva of bugs; this virus may be activated by gamma radiation and causes the development of papillomas in the skin.

  16. Induction of skin papillomas in the rabbit, Oryctologus cuniculus, by bites of a blood-sucking insect, Cimex lectularius, irradiated by gamma rays

    SciTech Connect

    el-Mofty, M.M.; Sakr, S.A.; Younis, M.W. )

    1989-11-01

    Bed bugs, Cimex lectularius, irradiated with gamma rays were allowed to suck blood from shaved areas of the skin of rabbits, Oryctolagus cuniculus, 2 times/week for 5 months and then once weekly for another 5 months. This significantly induced the formation of skin papillomas and sweat gland hyperplasia in five out of nine experimental animals. It is speculated that the saliva of the irradiated bugs was activated by gamma rays and was responsible for the induction of skin papillomas. Because bed bugs play a significant role in the transmission of virus, it is also speculated that there is a virus in the saliva of bugs; this virus may be activated by gamma radiation and causes the development of papillomas in the skin.

  17. Pneumatic conveyance apparatus and process

    DOEpatents

    Heckendorn, Frank M.; Matzolf, Athneal D.; Hera, Kevin R.

    2010-05-04

    A pneumatic nozzle capable of removing dry solid debris, liquids, and mixtures of solid and liquid waste is provided. The pneumatic nozzle uses a pressurized gas stream to push materials through the nozzle. The force of a pressurized gas stream provides a partial vacuum to allow material to be introduced into an opening of a nozzle via a slight suction force. Thereafter, individual particles and materials introduced into the pneumatic nozzle are pushed by a stream of pressurized gas through the nozzle.

  18. Mucosal injury and. gamma. -irradiation produce persistent gastric ulcers in the rabbit. Evaluation of antiulcer drug binding to experimental ulcer sites

    SciTech Connect

    Yokel, R.A.; Dickey, K.M. )

    1991-05-01

    A method producing persistent gastric ulcers in the rhesus monkey by combined mucosal injury and {gamma}-irradiation was modified and evaluated in the rabbit. {gamma}-Irradiation (800-1000 cGy) immediately after removal of 2-mm-diameter sections of antral mucosa resulted in ulcer craters 5-7 days later. Ulcer sites were characterized by loss of the mucosa, muscularis mucosa, and much of the submucosa. The exposed submucosa was coated with fibrin and necrotic debris infiltrated with heterophils, the rabbit equivalent of neutrophils. These ulcers strongly resemble human chronic gastric ulcers. Binding of Carafate (sucralfate; Marion Laboratories, Inc., Kansas City, MO) and Maalox (magnesia-alumina oral suspension; Wm. H. Rorer, Inc., Ft. Washington, PA) to ulcer and nearby nonulcer sites in the antrum was assessed 1 hour after drug dosing. Drug binding was determined by aluminum quantitation of stomach wall punch biopsies at necropsy. Both drugs significantly increased aluminum bound to the stomach wall compared with vehicle treatment. Significantly more antiulcer drug was bound to ulcer sites than to nearby nonulcer sites only after sucralfate administration. This model of persistent gastric ulcer should be useful to further study gastric ulcer pathogenesis and treatment.

  19. The complication of pneumatic retinopexy.

    PubMed Central

    Hilton, G F; Tornambe, P E; Brinton, D A; Flood, T P; Green, S; Grizzard, W S; Hammer, M E; Leff, S R; Mascuilli, L; Morgan, C M

    1990-01-01

    There have been 26 published series with a total of 1274 detachments operated with pneumatic retinopexy. Eighty percent were reattached with a single procedure and 98% with reoperations. New breaks occurred in 13% and PVR in 4%. The complications published in 101 papers on pneumatic retinopexy in the last 5 years are analyzed as to frequency, prevention, management, and results. PMID:2095021

  20. Pneumatically actuated micropipetting device

    NASA Astrophysics Data System (ADS)

    Szita, Nicolas; Buser, Rudolf A.

    1998-03-01

    We have realized a valveless micropipetting device with an integrated sensor which can aspirate and dispense liquid volumes without any valves, hence without any reflow or dead volume. With an external pneumatic actuation, we have demonstrated aspirating and dispensing from 190nl of 6 (mu) l of water. Measurements showed a standard deviation of down to 1 percent. An integrated capacitive sensor will allow monitoring of the pressure throughout the pipetting process and detect malfunctions, e.g. clotting of the pipetting tip. It is our intention to use this demonstrated precise aspiration mechanism in combination with a micromachined reaction chamber and a miniaturized optical analysis system.

  1. Pneumatic stowing seals mines

    SciTech Connect

    Brezovec, D.

    1983-11-01

    A mechanized technique to seal abandoned mines has been used successfully to close 13 openings at Duquesne Light Co.'s mined-out Warwick No. 2 mine, near Greensboro, Pa. The mechanized system, which uses a pneumatic stower and crushed limestone, closed the entries more economically and in less time than it would have taken to install traditional concrete block stopping and clay plug seals, according to John C. Draper. Draper, a mining engineer with Duquesne Light's coal department, was in charge of installing the Warwick seals in a Bureau of Mines-sponsored field test on the pneumatic sealing technique. The lowest estimated cost for installing conventional stopping and plug closures for the 13 Warwick openings was $225,000, says Draper, while the openings were closed using the mechanized system for $245,000. Draper says the newer stopping cost more in the instance because work was stopped often to gather information for the experiment. The experimental closures were installed in 38 days. The job would have taken at least 149 days if traditional closures were being installed, Draper say. To install a traditional concrete block/clay plug closure, the mine opening must be cleaned thoroughly and the roof must be supported for some 3 ft from the outside. Then a solid wall or stopping must be built 25 ft from the surface and the entry must be packed with clay to the surface. Much of this job requires workers to remain underground. In pneumatic stowing, 1 1/2-in. crushed limestone with fines is conveyed through a pipeline and into the mine opening under low air pressure. Watertight seals can be installed by blowing about 10 ft of rock into the opening against the top to act as roof support. Safety posts are installed and about 10 or 15 ft of mine entry is cleaned. About 2 in. of raw cement or bentonite is placed on the floor and limestone mixed with dry cement or bentonite is blown into the opening.

  2. Common-path Fourier domain optical coherence tomography of irradiated human skin and ventilated isolated rabbit lungs

    NASA Astrophysics Data System (ADS)

    Popp, A.; Wendel, M.; Knels, L.; Knuschke, P.; Mehner, M.; Koch, T.; Boller, D.; Koch, P.; Koch, E.

    2005-08-01

    A compact common path Fourier domain optical coherence tomography (FD-OCT) system based on a broadband superluminescence diode is used for biomedical imaging. The epidermal thickening of human skin after exposure to ultraviolet radiation is measured to proof the feasibility of FD-OCT for future substitution of invasive biopsies in a long term study on natural UV skin protection. The FD-OCT system is also used for imaging lung parenchyma. FD-OCT images of a formalin fixated lung show the same alveolar structure as scanning electron microscopy images. In the ventilated and blood-free perfused isolated rabbit lung FD-OCT is used for real-time cross-sectional image capture of alveolar mechanics throughout tidal ventilation. The alveolar mechanics changing from alternating recruitment-derecruitment at zero positive end-expiratory pressure (PEEP) to persistent recruitment after applying a PEEP of 5 cm H2O is observed in the OCT images.

  3. Automatic irradiation control by an optical feedback technique for selective retina treatment (SRT) in a rabbit model

    NASA Astrophysics Data System (ADS)

    Seifert, Eric; Roh, Young-Jung; Fritz, Andreas; Park, Young Gun; Kang, Seungbum; Theisen-Kunde, Dirk; Brinkmann, Ralf

    2013-06-01

    Selective Retina Therapy (SRT) targets the Retinal Pigment Epithelium (RPE) without effecting neighboring layers as the photoreceptors or the choroid. SRT related RPE defects are ophthalmoscopically invisible. Owing to this invisibility and the variation of the threshold radiant exposure for RPE damage the treating physician does not know whether the treatment was successful or not. Thus measurement techniques enabling a correct dosing are a demanded element in SRT devices. The acquired signal can be used for monitoring or automatic irradiation control. Existing monitoring techniques are based on the detection of micro-bubbles. These bubbles are the origin of RPE cell damage for pulse durations in the ns and μs time regime 5μs. The detection can be performed by optical or acoustical approaches. Monitoring based on an acoustical approach has already been used to study the beneficial effects of SRT on diabetic macula edema and central serous retinopathy. We have developed a first real time feedback technique able to detect micro-bubble induced characteristics in the backscattered laser light fast enough to cease the laser irradiation within a burst. Therefore the laser energy within a burst of at most 30 pulses is increased linearly with every pulse. The laser irradiation is ceased as soon as micro-bubbles are detected. With this automatic approach it was possible to observe invisible lesions, an intact photoreceptor layer and a reconstruction of the RPE within one week.

  4. 49 CFR 236.590 - Pneumatic apparatus.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Pneumatic apparatus. 236.590 Section 236.590..., Train Control and Cab Signal Systems Inspection and Tests; Locomotive § 236.590 Pneumatic apparatus. Automatic train stop, train control, or cab signal pneumatic apparatus shall be inspected, cleaned, and...

  5. 49 CFR 236.590 - Pneumatic apparatus.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 4 2011-10-01 2011-10-01 false Pneumatic apparatus. 236.590 Section 236.590..., Train Control and Cab Signal Systems Inspection and Tests; Locomotive § 236.590 Pneumatic apparatus. Automatic train stop, train control, or cab signal pneumatic apparatus shall be inspected, cleaned, and...

  6. Complications of occipital bone pneumatization.

    PubMed

    Moss, Mary; Biggs, Michael; Fagan, Paul; Forer, Martin; Davis, Martin; Roche, Jim

    2004-06-01

    Four cases of occipital bone pneumatization and subsequent complications are described, which include a pathological fracture of C1 and the occipital bone, spontaneous subcutaneous emphysema and pneumatocele formation. Reviews of the published literature and possible aetiological factors have been discussed. PMID:15230770

  7. Pneumatic gap sensor and method

    DOEpatents

    Bagdal, K.T.; King, E.L.; Follstaedt, D.W.

    1992-03-03

    An apparatus and method for monitoring and maintaining a predetermined width in the gap between a casting nozzle and a casting wheel, wherein the gap is monitored by means of at least one pneumatic gap sensor. The pneumatic gap sensor is mounted on the casting nozzle in proximity to the casting surface and is connected by means of a tube to a regulator and a transducer. The regulator provides a flow of gas through a restictor to the pneumatic gap sensor, and the transducer translates the changes in the gas pressure caused by the proximity of the casting wheel to the pneumatic gap sensor outlet into a signal intelligible to a control device. The relative positions of the casting nozzle and casting wheel can thereby be selectively adjusted to continually maintain a predetermined distance between their adjacent surfaces. The apparatus and method enables accurate monitoring of the actual casting gap in a simple and reliable manner resistant to the extreme temperatures and otherwise hostile casting environment. 6 figs.

  8. Pneumatic gap sensor and method

    DOEpatents

    Bagdal, Karl T.; King, Edward L.; Follstaedt, Donald W.

    1992-01-01

    An apparatus and method for monitoring and maintaining a predetermined width in the gap between a casting nozzle and a casting wheel, wherein the gap is monitored by means of at least one pneumatic gap sensor. The pneumatic gap sensor is mounted on the casting nozzle in proximity to the casting surface and is connected by means of a tube to a regulator and a transducer. The regulator provides a flow of gas through a restictor to the pneumatic gap sensor, and the transducer translates the changes in the gas pressure caused by the proximity of the casting wheel to the pneumatic gap sensor outlet into a signal intelligible to a control device. The relative positions of the casting nozzle and casting wheel can thereby be selectively adjusted to continually maintain a predetermined distance between their adjacent surfaces. The apparatus and method enables accurate monitoring of the actual casting gap in a simple and reliable manner resistant to the extreme temperatures and otherwise hostile casting environment.

  9. Experimental Plan for EDF Energy Creep Rabbit Graphite Irradiations- Rev. 2 (replaces Rev. 0 ORNL/TM/2013/49).

    SciTech Connect

    Burchell, Timothy D

    2014-07-01

    The experimental results obtained here will assist in the development and validation of future models of irradiation induced creep of graphite by providing the following data: Inert creep stain data from low to lifetime AGR fluence Inert creep-property data (especially CTE) from low to lifetime AGR fluence Effect of oxidation on creep modulus (by indirect comparison with experiment 1 and direct comparison with experiment 3 NB. Experiment 1 and 3 are not covered here) Data to develop a mechanistic understanding, including oAppropriate creep modulus (including pinning and high dose effects on structure) oInvestigation of CTE-creep strain behavior under inert conditions oInformation on the effect of applied stress/creep strain on crystallite orientation (requires XRD) oEffect of creep strain on micro-porosity (requires tomography & microscopy) This document describes the experimental work planned to meet the requirements of project technical specification [1] and EDF Energy requests for additional Pre-IE work. The PIE work is described in detail in this revision (Section 8 and 9).

  10. Sliding pressure control valve for pneumatic hammer drill

    SciTech Connect

    Polsky, Yarom

    2011-08-30

    A pneumatic device control apparatus and method comprising a ported valve slidably fitted over a feed tube of the pneumatic device, and using a compliant biasing device to constrain motion of the valve to provide asymmetric timing for extended pressurization of a power chamber and reduced pressurization of a return chamber of the pneumatic device. The pneumatic device can be a pneumatic hammer drill.

  11. Model for pneumatic pellet injection

    SciTech Connect

    Hogan, J.T.; Milora, S.L.; Schuresko, D.D.

    1983-07-01

    A hydrodynamic code has been developed to model the performance of pneumatic pellet injection systems. The code describes one dimensional, unsteady compressible gas dynamics, including gas friction and heat transfer to the walls in a system with variable area. The mass, momentum, and energy equations are solved with an iterated Lax-Wendroff scheme with additional numerical viscosity. The code is described and comparisons with experimental data are presented.

  12. Electric versus hydraulics versus pneumatics

    SciTech Connect

    Not Available

    1985-01-01

    This book presents a collection of papers from a conference which considered the advantages and disadvantages of electric, hydraulic and pneumatic drives and actuators. The volume follows on the success of the 1983 conference on electric and hydraulic drives. Topics considered include fork lift trucks - an ideal application for regenerative transmissions; a hybrid-electric power system with hydrostatic transmission; electrics and hydraulics on roadheader machinery; hydraulic, electrical, pneumatic control - which way to go. an electrically-powered servo to drive the two axes of a missile launching platform - pros and cons when compared with the traditional hydraulic solution; the encapsulation of a novel intrinsically safe displacement transducer; mobile cryogenic pumping systems; automation of a wood-turning machine, hydraulic or electric. The choice of a servo motor for a specific application; developments in the design and control of pneumatic linear actuators; compressed air purification for instrumentation in the high technology industries; trends in prime mover choice for powered hand tools; and choosing the drive system for the right application.

  13. [Modern pneumatic weapons and injuries they cause].

    PubMed

    Kozachenko, I N

    2013-01-01

    The data on the history of development and further improvement of pneumatic weapons are presented with special reference to specific features of different types and varieties of these weapons, cartridges for them, and the sphere of their application. Investigations into peculiarities of damages caused by high-capacity pneumatic weapons to the objects of forensic medical expertise affected from different distances are reviewed. Results of forensic medical expertise and clinical studies on the structure of body injuries inflicted by gunshots from pneumatic weapons to the human body are discussed. The author emphasizes the necessity of developing up-to-date terminology and classification of gunshot injuries caused by shooting from pneumatic weapons.

  14. 21 CFR 878.5910 - Pneumatic tourniquet.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ...) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Therapeutic Devices § 878.5910 Pneumatic tourniquet... patient's limb and inflated to reduce or totally occlude circulation during surgery. (b)...

  15. 21 CFR 878.5910 - Pneumatic tourniquet.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ...) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Therapeutic Devices § 878.5910 Pneumatic tourniquet... patient's limb and inflated to reduce or totally occlude circulation during surgery. (b)...

  16. 21 CFR 878.5910 - Pneumatic tourniquet.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ...) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Therapeutic Devices § 878.5910 Pneumatic tourniquet... patient's limb and inflated to reduce or totally occlude circulation during surgery. (b)...

  17. 21 CFR 878.5910 - Pneumatic tourniquet.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ...) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Therapeutic Devices § 878.5910 Pneumatic tourniquet... patient's limb and inflated to reduce or totally occlude circulation during surgery. (b)...

  18. 21 CFR 878.5910 - Pneumatic tourniquet.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ...) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Therapeutic Devices § 878.5910 Pneumatic tourniquet... patient's limb and inflated to reduce or totally occlude circulation during surgery. (b)...

  19. Note: A fast pneumatic sample-shuttle with attenuated shocks

    SciTech Connect

    Biancalana, Valerio; Dancheva, Yordanka; Stiaccini, Leonardo

    2014-03-15

    We describe a home-built pneumatic shuttle suitable for the fast displacement of samples in the vicinity of a highly sensitive atomic magnetometer. The samples are magnetized at 1 T using a Halbach assembly of magnets. The device enables the remote detection of free-induction-decay in ultra-low-field and zero-field nuclear magnetic resonance (NMR) experiments, in relaxometric measurements and in other applications involving the displacement of magnetized samples within time intervals as short as a few tens of milliseconds. Other possible applications of fast sample shuttling exist in radiological studies, where samples have to be irradiated and then analyzed in a cold environment.

  20. Pneumatic conveying of pulverized solvent refined coal

    DOEpatents

    Lennon, Dennis R.

    1984-11-06

    A method for pneumatically conveying solvent refined coal to a burner under conditions of dilute phase pneumatic flow so as to prevent saltation of the solvent refined coal in the transport line by maintaining the transport fluid velocity above approximately 95 ft/sec.

  1. RANGE INCREASER FOR PNEUMATIC GAUGES

    DOEpatents

    Fowler, A.H.; Seaborn, G.B. Jr.

    1960-09-27

    An improved pneumatic gage is offered in which the linear range has been increased without excessive air consumption. This has been accomplished by providing an expansible antechamber connected to the nozzle of the gage so that the position of the nozzle with respect to the workpiece is varied automatically by variation in pressure within the antechamber. This arrangement ensures that the nozzle-to-workpiece clearance is maintained within certain limits, thus obtaining a linear relation of air flow to nozzle-to-workpiece clearance over a wider range.

  2. Pneumatically tunable optofluidic dye laser

    NASA Astrophysics Data System (ADS)

    Song, Wuzhou; Psaltis, Demetri

    2010-02-01

    We presented a tunable optofluidic dye laser with integrated elastomeric air-gap etalon controlled by air pressure. The chip was fabricated with polydimethylsiloxane (PDMS) via replica molding. It comprises a liquid waveguide and microscale air-gap mirrors providing the feedback. The lasing wavelength is chosen by the interference between two parallel PDMS-air interfaces inside the internal tunable air-gap etalon, of which pneumatic tuning can be realized by inflating the air-gap etalon with compressed air. This dye laser exhibits a pumping threshold of 1.6 μJ/pulse, a lasing linewidth of 3 nm, and a tuning range of 14 nm.

  3. Caudal pneumaticity and pneumatic hiatuses in the sauropod dinosaurs Giraffatitan and Apatosaurus.

    PubMed

    Wedel, Mathew J; Taylor, Michael P

    2013-01-01

    Skeletal pneumaticity is found in the presacral vertebrae of most sauropod dinosaurs, but pneumaticity is much less common in the vertebrae of the tail. We describe previously unrecognized pneumatic fossae in the mid-caudal vertebrae of specimens of Giraffatitan and Apatosaurus. In both taxa, the most distal pneumatic vertebrae are separated from other pneumatic vertebrae by sequences of three to seven apneumatic vertebrae. Caudal pneumaticity is not prominent in most individuals of either of these taxa, and its unpredictable development means that it may be more widespread than previously recognised within Sauropoda and elsewhere in Saurischia. The erratic patterns of caudal pneumatization in Giraffatitan and Apatosaurus, including the pneumatic hiatuses, show that pneumatic diverticula were more broadly distributed in the bodies of the living animals than are their traces in the skeleton. Together with recently published evidence of cryptic diverticula--those that leave few or no skeletal traces--in basal sauropodomorphs and in pterosaurs, this is further evidence that pneumatic diverticula were widespread in ornithodirans, both across phylogeny and throughout anatomy.

  4. Caudal Pneumaticity and Pneumatic Hiatuses in the Sauropod Dinosaurs Giraffatitan and Apatosaurus

    PubMed Central

    Wedel, Mathew J.; Taylor, Michael P.

    2013-01-01

    Skeletal pneumaticity is found in the presacral vertebrae of most sauropod dinosaurs, but pneumaticity is much less common in the vertebrae of the tail. We describe previously unrecognized pneumatic fossae in the mid-caudal vertebrae of specimens of Giraffatitan and Apatosaurus. In both taxa, the most distal pneumatic vertebrae are separated from other pneumatic vertebrae by sequences of three to seven apneumatic vertebrae. Caudal pneumaticity is not prominent in most individuals of either of these taxa, and its unpredictable development means that it may be more widespread than previously recognised within Sauropoda and elsewhere in Saurischia. The erratic patterns of caudal pneumatization in Giraffatitan and Apatosaurus, including the pneumatic hiatuses, show that pneumatic diverticula were more broadly distributed in the bodies of the living animals than are their traces in the skeleton. Together with recently published evidence of cryptic diverticula—those that leave few or no skeletal traces—in basal sauropodomorphs and in pterosaurs, this is further evidence that pneumatic diverticula were widespread in ornithodirans, both across phylogeny and throughout anatomy. PMID:24205162

  5. Bone and joint changes in pneumatic drillers.

    PubMed Central

    Burke, M J; Fear, E C; Wright, V

    1977-01-01

    A clinical and radiological survey of 34 men who were pneumatic drillers employed by the North East Gas Board, was carried out to determine the prevalence of osteoarthrosis. Mild osteoarthrosis of the elbows was found in 2 subjects only. Two drillers had radiological evidence of generalized osteoarthrosis elsewhere, and minor degenerative changes were present in the hands of 15 cases. Our findings do not support the view that pneumatic drillers are particularly prone to develop osteoarthrosis. Images PMID:879868

  6. Pneumatic fracturing of low permeability media

    SciTech Connect

    Schuring, J.R.

    1996-08-01

    Pneumatic fracturing of soils to enhance the removal and treatment of dense nonaqueous phase liquids is described. The process involves gas injection at a pressure exceeding the natural stresses and at a flow rate exceeding the permeability of the formation. The paper outlines geologic considerations, advantages and disadvantages, general technology considerations, low permeability media considerations, commercial availability, efficiency, and costs. Five case histories of remediation using pneumatic fracturing are briefly summarized. 11 refs., 2 figs., 1 tab.

  7. Promising pneumatic punchers for borehole drilling

    SciTech Connect

    A.A. Lipin

    2005-03-15

    The state of borehole drilling by downhole pneumatic punchers and their potential use in open and underground mining as well as in exploration for reliable sampling are analyzed. Performance specification is presented for the new-generation pneumatic punchers equipped with a pin tool, effectively operating at a compressed-air pressure of 0.5-0.7 MPa, and with an additional extended exhaust from the power stroke chamber during working cycle.

  8. A pneumatic transfer system for special form {sup 252}Cf

    SciTech Connect

    Gehrke, R.J.; Berry, S.M.; Grafwallner, E.G.; Hoggan, J.M.

    1996-09-01

    A pneumatic transfer system has been developed for use with series 100 Special Form {sup 252}Cf. It was developed to reduce the exposure to personnel handling sources of {sup 252}Cf with masses up to 150 {micro}g by permitting remotely activated two-way transfer between the storage container and the irradiation position. The pneumatic transfer system also permits transfers for reproducible repetitive irradiation periods. In addition to the storage container equipped with quick-release fittings, the transfer system consists of an irradiation station, a control box with momentary contact switches to activate the air-pressure control valves and indicators to identify the location of the source, and connecting air hose and electrical wire. A source of 20 psig air and 110 volt electrical power are required for operation of the transfer system which can be easily moved and set up by one individual in 5 to 10 minutes. Tests have shown that rarely does a source become lodged in the transfer tubing, but two methods have been developed to handle incomplete transfers of the {sup 252}Cf source. The first method consists of closing one air vent to allow a pressure impulse to propel the source to the opposite side. The second method applies to those {sup 252}Cf capsules with a threaded or tapped end to which a small ferromagnetic piece can be attached; an incompletely transferred source in the transfer tube can then be guided to a position of safety by surrounding the transfer tubing containing the capsule with a horseshoe magnet attached to the end of a long pole.

  9. Pneumatic gap sensor and method

    SciTech Connect

    Bagdal, K.T.; King, E.L.; Follstaedt, D.W.

    1992-03-03

    This patent describes in a casting system which including an apparatus for monitoring the gap between a casting nozzle and a casting surface of a substrate during casting of molten material, wherein the molten material is provided through a channel of the casting nozzle for casting onto the casting surface of the substrate for solidification. It comprises: a pneumatic gap mounted at least partially within a cavity in the casting nozzle adjacent the channel and having a sensor face located within the gap between the nozzle and the casting surface of the substrate, means for supply gas under predetermined pressure to the inlet orifice; and means for measuring the pressure of the gas within the sensor chamber during casting procedures, whereby relative changes in the gap can be determined by corresponding changes in the measured pressure. This patent also describes a method for monitoring the gap between a casting nozzle and a casting surface of a substrate for continuous casting of molten material. It comprises: providing a casting nozzle with a channel for directing the flow of molten material, locating the nozzle and the casting surface is proximity with one another and having a predetermined gap there-between, and dressing the sensor face to correspond in conformation to the casting surface and to adjust the predetermined distance as desired; providing a molten material to the nozzle for casting onto and casting surface; supplying gas at a predetermined pressure to the inlet orifice of the sensor during casting procedures.

  10. Milestone M3FT-15OR0203112. Build redesigned HFIR rabbit capsules and make ready for insertion for irradiation in HFIR

    SciTech Connect

    Howard, Richard H; McDuffee, Joel Lee; Okuniewski, Maria A.

    2015-09-01

    This report details the fabrication and delivery of two Fuel Cycle Research and Development irradiation capsules (FCRP20 and FCRP03), with associated quality assurance documentation, to the High Flux Isotope Reactor. The capsules and documentation were delivered by September 30, 2015, thus meeting the deadline for milestone M3FT-15OR0203112. These irradiation experiments irradiate metal parallelepiped specimens that may consist of various compositions including uranium metal, steel, etc. This document contains a copy of the completed capsule fabrication request sheets, which detail all constituent components, pertinent drawings, etc., along with a detailed summary of the capsule assembly process performed by the Thermal Hydraulics and Irradiation Engineering Group (THIEG) in the Reactor and Nuclear Systems Division. A complete fabrication package record is maintained by THIEG and is available upon request.

  11. Pneumatic dilatation for childhood achalasia.

    PubMed

    Babu, R; Grier, D; Cusick, E; Spicer, R D

    2001-09-01

    Treatment of achalasia by pneumatic balloon dilatation (PBD) is well established in adults. Due to limited experience and the rarity of the condition in children, there are relatively few reports in the paediatric literature. Although PBD has been reported as a primary method of treatment, there are no reports of secondary PBD for childhood achalasia. Between 1995 and 1999, five patients underwent treatment for achalasia (age: 9-14 years, M:F = 4:1). The presenting symptoms were dysphagia (5). vomiting episodes (2), aspiration (1), food-bolus obstruction (1), and failure to thrive (1). In all patients a barium swallow and manometry were used to confirm the diagnosis. Three underwent primary PBD. Two who had previously undergone surgical myotomy underwent secondary PBD for recurrence of symptoms. Dilatation was performed using a 35-mm balloon with the child under general anaesthesia. Technical success was defined as demonstration of a waist under screening at lower pressures followed by abolition of the waist at higher pressures. In addition to reviewing our results, a systematic review of the literature was performed (Medline, Cochrane Library, Pubmed, Embase). Three patients (primary dilatation) showed excellent improvement after a single dilatation. In two cases (secondary dilatation) three and five attempts were required. No complications were encountered. The mean follow-up period was 2 years (1-3.5 years) and four patients remained asymptomatic, an overall success rate of 80%. The literature review revealed similar good results in most of the recent reports. Thus, PBD as a primary treatment for childhood achalasia has a success rate of 70%-90% with minimal side effects, short hospital stay, and good patient acceptability over an operation. We have also established the usefulness of this method as a secondary treatment when symptoms recur after surgery.

  12. Carbon Nanotube Amperometric Chips with Pneumatic Micropumps

    NASA Astrophysics Data System (ADS)

    Tsujita, Yuichi; Maehashi, Kenzo; Matsumoto, Kazuhiko; Chikae, Miyuki; Torai, Soichiro; Takamura, Yuzuru; Tamiya, Eiichi

    2008-04-01

    We fabricated carbon nanotube (CNT) amperometric chips with pneumatic micropumps by the combination of amperometric biosensors based on CNT-arrayed electrodes and microchannels with pneumatic micropumps made of poly(dimethylsiloxane). On the chip, phosphate buffer solution and potassium ferricyanide, K3[Fe(CN)6], were introduced into the CNT electrodes using each pneumatic micropump and electrochemically measured by differential pulse voltammetry. The results indicate that our chip can automatically exchange reagents on the CNT electrodes and clearly detect molecules. Moreover, by modifying the CNT electrodes with enzyme glucose oxidase, glucose molecules could be detected using our chips by cyclic voltammetry and chronoamperometry. We conclude that microfluidic chips with CNT-arrayed electrodes are a promising candidate for the development of hand-held electrochemical biosensors.

  13. 21 CFR 882.4370 - Pneumatic cranial drill motor.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Pneumatic cranial drill motor. 882.4370 Section... drill motor. (a) Identification. A pneumatic cranial drill motor is a pneumatically operated power source used with removable rotating surgical cutting tools or drill bits on a patient's skull....

  14. 21 CFR 882.4370 - Pneumatic cranial drill motor.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Pneumatic cranial drill motor. 882.4370 Section... drill motor. (a) Identification. A pneumatic cranial drill motor is a pneumatically operated power source used with removable rotating surgical cutting tools or drill bits on a patient's skull....

  15. 21 CFR 882.4370 - Pneumatic cranial drill motor.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Pneumatic cranial drill motor. 882.4370 Section... drill motor. (a) Identification. A pneumatic cranial drill motor is a pneumatically operated power source used with removable rotating surgical cutting tools or drill bits on a patient's skull....

  16. 21 CFR 882.4370 - Pneumatic cranial drill motor.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Pneumatic cranial drill motor. 882.4370 Section... drill motor. (a) Identification. A pneumatic cranial drill motor is a pneumatically operated power source used with removable rotating surgical cutting tools or drill bits on a patient's skull....

  17. 21 CFR 882.4370 - Pneumatic cranial drill motor.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Pneumatic cranial drill motor. 882.4370 Section... drill motor. (a) Identification. A pneumatic cranial drill motor is a pneumatically operated power source used with removable rotating surgical cutting tools or drill bits on a patient's skull....

  18. 21 CFR 870.2780 - Hydraulic, pneumatic, or photoelectric plethysmographs.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Hydraulic, pneumatic, or photoelectric... § 870.2780 Hydraulic, pneumatic, or photoelectric plethysmographs. (a) Identification. A hydraulic, pneumatic, or photoelectric plethysmograph is a device used to estimate blood flow in a region of the...

  19. 49 CFR 236.817 - Switch, electro-pneumatic.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 4 2011-10-01 2011-10-01 false Switch, electro-pneumatic. 236.817 Section 236.817 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION... Switch, electro-pneumatic. A switch operated by an electro-pneumatic switch-and-lock movement....

  20. 14 CFR 25.1438 - Pressurization and pneumatic systems.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Pressurization and pneumatic systems. 25... § 25.1438 Pressurization and pneumatic systems. (a) Pressurization system elements must be burst.... (b) Pneumatic system elements must be burst pressure tested to 3.0 times, and proof pressure...

  1. 14 CFR 25.1438 - Pressurization and pneumatic systems.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Pressurization and pneumatic systems. 25... § 25.1438 Pressurization and pneumatic systems. (a) Pressurization system elements must be burst.... (b) Pneumatic system elements must be burst pressure tested to 3.0 times, and proof pressure...

  2. 14 CFR 23.1438 - Pressurization and pneumatic systems.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Pressurization and pneumatic systems. 23... Equipment Miscellaneous Equipment § 23.1438 Pressurization and pneumatic systems. (a) Pressurization system... normal operating pressure. (b) Pneumatic system elements must be burst pressure tested to 3.0 times,...

  3. 14 CFR 23.1438 - Pressurization and pneumatic systems.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Pressurization and pneumatic systems. 23... Equipment Miscellaneous Equipment § 23.1438 Pressurization and pneumatic systems. (a) Pressurization system... normal operating pressure. (b) Pneumatic system elements must be burst pressure tested to 3.0 times,...

  4. 49 CFR 236.817 - Switch, electro-pneumatic.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Switch, electro-pneumatic. 236.817 Section 236.817 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION... Switch, electro-pneumatic. A switch operated by an electro-pneumatic switch-and-lock movement....

  5. 30 CFR 56.14114 - Air valves for pneumatic equipment.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Air valves for pneumatic equipment. 56.14114... Equipment Safety Devices and Maintenance Requirements § 56.14114 Air valves for pneumatic equipment. A manual master quick-close type air valve shall be installed on all pneumatic-powered equipment if...

  6. 30 CFR 56.14114 - Air valves for pneumatic equipment.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Air valves for pneumatic equipment. 56.14114... Equipment Safety Devices and Maintenance Requirements § 56.14114 Air valves for pneumatic equipment. A manual master quick-close type air valve shall be installed on all pneumatic-powered equipment if...

  7. 30 CFR 57.14114 - Air valves for pneumatic equipment.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Air valves for pneumatic equipment. 57.14114... and Equipment Safety Devices and Maintenance Requirements § 57.14114 Air valves for pneumatic equipment. A manual master quick-close type air valve shall be installed on all pneumatic-powered...

  8. 30 CFR 57.14114 - Air valves for pneumatic equipment.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Air valves for pneumatic equipment. 57.14114... and Equipment Safety Devices and Maintenance Requirements § 57.14114 Air valves for pneumatic equipment. A manual master quick-close type air valve shall be installed on all pneumatic-powered...

  9. 21 CFR 870.2780 - Hydraulic, pneumatic, or photoelectric plethysmographs.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Hydraulic, pneumatic, or photoelectric... § 870.2780 Hydraulic, pneumatic, or photoelectric plethysmographs. (a) Identification. A hydraulic... using hydraulic, pneumatic, or photoelectric measurement techniques. (b) Classification. Class...

  10. PNEUMATIC PUMP TEST FOR DESIGN OF SOIL VACUUM EXTRACTION

    EPA Science Inventory

    In-situ pneumatic pumping tests were performed to estimate the pneumatic permeability at a site containing soils contaminated with aviation gasoline. Determination of pneumatic permeability was necessary to evaluate soil-air discharge or pore volume exchange rates. Pressure propa...

  11. Vertebral Pneumaticity in the Ornithomimosaur Archaeornithomimus (Dinosauria: Theropoda) Revealed by Computed Tomography Imaging and Reappraisal of Axial Pneumaticity in Ornithomimosauria

    PubMed Central

    Watanabe, Akinobu; Eugenia Leone Gold, Maria; Brusatte, Stephen L.; Benson, Roger B. J.; Choiniere, Jonah; Davidson, Amy; Norell, Mark A.

    2015-01-01

    Among extant vertebrates, pneumatization of postcranial bones is unique to birds, with few known exceptions in other groups. Through reduction in bone mass, this feature is thought to benefit flight capacity in modern birds, but its prevalence in non-avian dinosaurs of variable sizes has generated competing hypotheses on the initial adaptive significance of postcranial pneumaticity. To better understand the evolutionary history of postcranial pneumaticity, studies have surveyed its distribution among non-avian dinosaurs. Nevertheless, the degree of pneumaticity in the basal coelurosaurian group Ornithomimosauria remains poorly known, despite their potential to greatly enhance our understanding of the early evolution of pneumatic bones along the lineage leading to birds. Historically, the identification of postcranial pneumaticity in non-avian dinosaurs has been based on examination of external morphology, and few studies thus far have focused on the internal architecture of pneumatic structures inside the bones. Here, we describe the vertebral pneumaticity of the ornithomimosaur Archaeornithomimus with the aid of X-ray computed tomography (CT) imaging. Complementary examination of external and internal osteology reveals (1) highly pneumatized cervical vertebrae with an elaborate configuration of interconnected chambers within the neural arch and the centrum; (2) anterior dorsal vertebrae with pneumatic chambers inside the neural arch; (3) apneumatic sacral vertebrae; and (4) a subset of proximal caudal vertebrae with limited pneumatic invasion into the neural arch. Comparisons with other theropod dinosaurs suggest that ornithomimosaurs primitively exhibited a plesiomorphic theropod condition for axial pneumaticity that was extended among later taxa, such as Archaeornithomimus and large bodied Deinocheirus. This finding corroborates the notion that evolutionary increases in vertebral pneumaticity occurred in parallel among independent lineages of bird

  12. Vertebral Pneumaticity in the Ornithomimosaur Archaeornithomimus (Dinosauria: Theropoda) Revealed by Computed Tomography Imaging and Reappraisal of Axial Pneumaticity in Ornithomimosauria.

    PubMed

    Watanabe, Akinobu; Eugenia Leone Gold, Maria; Brusatte, Stephen L; Benson, Roger B J; Choiniere, Jonah; Davidson, Amy; Norell, Mark A

    2015-01-01

    Among extant vertebrates, pneumatization of postcranial bones is unique to birds, with few known exceptions in other groups. Through reduction in bone mass, this feature is thought to benefit flight capacity in modern birds, but its prevalence in non-avian dinosaurs of variable sizes has generated competing hypotheses on the initial adaptive significance of postcranial pneumaticity. To better understand the evolutionary history of postcranial pneumaticity, studies have surveyed its distribution among non-avian dinosaurs. Nevertheless, the degree of pneumaticity in the basal coelurosaurian group Ornithomimosauria remains poorly known, despite their potential to greatly enhance our understanding of the early evolution of pneumatic bones along the lineage leading to birds. Historically, the identification of postcranial pneumaticity in non-avian dinosaurs has been based on examination of external morphology, and few studies thus far have focused on the internal architecture of pneumatic structures inside the bones. Here, we describe the vertebral pneumaticity of the ornithomimosaur Archaeornithomimus with the aid of X-ray computed tomography (CT) imaging. Complementary examination of external and internal osteology reveals (1) highly pneumatized cervical vertebrae with an elaborate configuration of interconnected chambers within the neural arch and the centrum; (2) anterior dorsal vertebrae with pneumatic chambers inside the neural arch; (3) apneumatic sacral vertebrae; and (4) a subset of proximal caudal vertebrae with limited pneumatic invasion into the neural arch. Comparisons with other theropod dinosaurs suggest that ornithomimosaurs primitively exhibited a plesiomorphic theropod condition for axial pneumaticity that was extended among later taxa, such as Archaeornithomimus and large bodied Deinocheirus. This finding corroborates the notion that evolutionary increases in vertebral pneumaticity occurred in parallel among independent lineages of bird

  13. Experimental investigation of pneumatic soil vapor extraction.

    PubMed

    Høier, C K; Sonnenborg, T O; Jensen, K H; Kortegaard, C; Nasser, M M

    2007-01-01

    Soil Vapor Extraction (SVE) is a common remediation technique for removing volatile organic compounds from unsaturated contaminated soils. Soil heterogeneities can however cause serious limitations to the applicability of SVE due to air bypassing low permeable areas of the soil, leading to diffusion limitation of the remediation. To enhance removal from areas subject to diffusion limitation a new remediation technique, pneumatic soil vapor extraction, is proposed. In contrast to traditional SVE, in which soil vapor is extracted continuously by a vacuum pump, pneumatic SVE is based on enforcing a sequence of large pressure drops on the system to enhance the recovery from the low-permeable areas. The pneumatic SVE technique was investigated in the laboratory using TCE as a model contaminant. 2D-laboratory tank experiments were performed on homogeneous and heterogeneous sand packs. The heterogeneous packs consisted of a fine sand lens surrounded by a coarser sand matrix. As expected when using traditional SVE, the removal of TCE from the low permeable lens was extremely slow and subject to diffusion limitation. In contrast when pneumatic venting was used removal rates increased by up to 77%. The enhanced removal was hypothesized to be attributed to mixing of the contaminated air inside the lens and generation of net advective transport out of the lens due to air expansion.

  14. Management of achalasia: surgery or pneumatic dilation.

    PubMed

    Richter, Joel E; Boeckxstaens, Guy E

    2011-06-01

    Achalasia is an esophageal motility disorder of unknown cause, characterised by aperistalsis of the esophageal body and impaired lower esophageal sphincter relaxation. Patients present at all ages, primarily with dysphagia for solids/liquids and bland regurgitation. The diagnosis is suggested by barium esophagram or endoscopy and confirmed by esophageal manometry. Achalasia cannot be cured. Instead, our goal is to relieve symptoms, improve esophageal emptying and prevent the development of megaesophagus. The most successful therapies are pneumatic dilation and surgical myotomy. The advantages of pneumatic dilation include an outpatient procedure, minimal pain, return to work the next day, mild if any GERD, and can be performed in any age group and even during pregnancy. Pneumatic dilation does not hinder future myotomy, and all cost analyses find it less expensive than Heller myotomy. Laparoscopic myotomy with a partial fundoplication has the advantage of being a single procedure, dysphagia relief is longer at the cost of more troubling heartburn, and a myotomy may be more effective treatment in adolescents and younger adults, especially men. Over a two year horizon, the clinical success of pneumatic dilation and laparoscopic myotomy are comparable in a recent large European randomised trial. The prognosis for achalasia patients to return to near-normal swallowing and good quality of life are excellent, but few are "cured" with a single treatment and intermittent "touch up" procedures may be required. PMID:21303915

  15. Distortion Of Pressure Signals In Pneumatic Tubes

    NASA Technical Reports Server (NTRS)

    Whitmore, Stephen A.; Gilyard, Glenn B.; Curry, Robert; Lindsey, William

    1993-01-01

    NASA technical memorandum describes experimental investigation of distorting effects of propagation of pressure signals along narrow pneumatic tubes from pressure-sensing orifices on surfaces of models or aircraft to pressure sensors distant from orifices. Pressure signals distorted principally by frictional damping along walls of tubes and by reflections at orifice and sensor ends.

  16. Experimental investigation of pneumatic soil vapor extraction.

    PubMed

    Høier, C K; Sonnenborg, T O; Jensen, K H; Kortegaard, C; Nasser, M M

    2007-01-01

    Soil Vapor Extraction (SVE) is a common remediation technique for removing volatile organic compounds from unsaturated contaminated soils. Soil heterogeneities can however cause serious limitations to the applicability of SVE due to air bypassing low permeable areas of the soil, leading to diffusion limitation of the remediation. To enhance removal from areas subject to diffusion limitation a new remediation technique, pneumatic soil vapor extraction, is proposed. In contrast to traditional SVE, in which soil vapor is extracted continuously by a vacuum pump, pneumatic SVE is based on enforcing a sequence of large pressure drops on the system to enhance the recovery from the low-permeable areas. The pneumatic SVE technique was investigated in the laboratory using TCE as a model contaminant. 2D-laboratory tank experiments were performed on homogeneous and heterogeneous sand packs. The heterogeneous packs consisted of a fine sand lens surrounded by a coarser sand matrix. As expected when using traditional SVE, the removal of TCE from the low permeable lens was extremely slow and subject to diffusion limitation. In contrast when pneumatic venting was used removal rates increased by up to 77%. The enhanced removal was hypothesized to be attributed to mixing of the contaminated air inside the lens and generation of net advective transport out of the lens due to air expansion. PMID:16987566

  17. Pneumatic boot for helicopter rotor deicing

    NASA Technical Reports Server (NTRS)

    Blaha, B. J.; Evanich, P. L.

    1981-01-01

    Pneumatic deicer boots for helicopter rotor blades were tested. The tests were conducted in the 6 by 9 ft icing research tunnel on a stationary section of a UH-IH helicopter main rotor blade. The boots were effective in removing ice and in reducing aerodynamic drag due to ice.

  18. Analysis of fine coal pneumatic systems

    SciTech Connect

    Mathur, M.P.; Rohatgi, N.D.; Klinzing, G.E.

    1987-01-01

    Many fossil fuel energy processes depend on the movement of solids by pneumatic transport. Despite the considerable amount of work reported in the literature on pneumatic transport, the design of new industrial systems for new products continues to rely to a great extent on empiricism. A pilot-scale test facility has been constructed at Pittsburgh Energy Technology Center (PETC) and is equipped with modern sophisticated measuring techniques (such as Pressure Transducers, Auburn Monitors, Micro Motion Mass flowmeters) and an automatic computer-controlled data acquisition system to study the effects of particle pneumatic transport. Pittsburgh Seam and Montana rosebud coals of varying size consist and moisture content were tested in the atmospheric and pressurized coal flow test loops (AP/CFTL and HP/CFTL) at PETC. The system parameters included conveying gas velocity, injector tank pressure, screw conveyor speed, pipe radius, and pipe bends. In the following report, results from the coal flow tests were presented and analyzed. Existing theories and correlations on two-phase flows were reviewed. Experimental data were compared with values calculated from empirically or theoretically derived equations available in the literature, and new correlations were proposed, when applicable, to give a better interpretation of the data and a better understanding of the various flow regimes involved in pneumatic transport. 55 refs., 56 figs., 6 tabs.

  19. Pneumatics. Student's Manual [and] Instructor's Guide.

    ERIC Educational Resources Information Center

    Notgrass, Troy

    The student's manual in this two-part instructional kit is designed to help the following types of students learn introductory technical material related to pneumatics: (1) groups of trade and industrial students with a variety of vocational objectives and (2) homogeneous groups in which the learning levels of individual students vary…

  20. Pneumatically Actuated Miniature Peristaltic Vacuum Pumps

    NASA Technical Reports Server (NTRS)

    Feldman, Sabrina; Feldman, Jason; Svehla, Danielle

    2003-01-01

    Pneumatically actuated miniature peristaltic vacuum pumps have been proposed for incorporation into advanced miniature versions of scientific instruments that depend on vacuum for proper operation. These pumps are expected to be capable of reaching vacuum-side pressures in the torr to millitorr range (from .133 down to .0.13 Pa). Vacuum pumps that operate in this range are often denoted roughing pumps. In comparison with previously available roughing pumps, these pumps are expected to be an order of magnitude less massive and less power-hungry. In addition, they would be extremely robust, and would operate with little or no maintenance and without need for oil or other lubricants. Portable mass spectrometers are typical examples of instruments that could incorporate the proposed pumps. In addition, the proposed pumps could be used as roughing pumps in general laboratory applications in which low pumping rates could be tolerated. The proposed pumps could be designed and fabricated in conventionally machined and micromachined versions. A typical micromachined version (see figure) would include a rigid glass, metal, or plastic substrate and two layers of silicone rubber. The bottom silicone layer would contain shallow pump channels covered by silicone arches that could be pushed down pneumatically to block the channels. The bottom silicone layer would be covered with a thin layer of material with very low gas permeability, and would be bonded to the substrate everywhere except in the channel areas. The top silicone layer would be attached to the bottom silicone layer and would contain pneumatic- actuation channels that would lie crosswise to the pump channels. This version is said to be micromachined because the two silicone layers containing the channels would be fabricated by casting silicone rubber on micromachined silicon molds. The pneumatic-actuation channels would be alternately connected to a compressed gas and (depending on pump design) either to atmospheric

  1. Myocardial hydroxyproline reduced by early administration of methylprednisolone or ibuprofen to rabbits with radiation-induced heart disease

    SciTech Connect

    Reeves, W.C.; Cunningham, D.; Schwiter, E.J.; Abt, A.; Skarlatos, S.; Wood, M.A.; Whitesell, L.

    1982-05-01

    The ability of methylprednisolone (MP) and ibuprofen (IB) to reduce the severity of the late state of radiation-induced heart disease was assessed in 57 New Zealand white rabbits. Before and shortly after cardiac irradiation, 15 rabbits received i.v. MP, 30 mg/kg twice daily for 3 days, and 15 others received IB, 12.5 mg/kg twice daily for 2 days. No drug was administered to 14 irradiated rabbits, and neither irradiation nor drugs were administered to 13 rabbits that served as controls, All 15 rabbits treated with MP and 13 of the 15 treated with IB lived for 100 days. Only seven of the untreated, irradiated rabbits lived that long. Longevity of each treated group of rabbits was better (p less than 0.01 and 0.05) than that of the untreated, irradiated rabbits. Surviving rabbits were killed 100 days after irradiation. Pericarditis (p less than 0.05) and pericardial effusion (p less than 0.01) were less frequent in the treated, irradiated groups than in the untreated, irradiated rabbits. At least some rabbits in each irradiated group had microscopic evidence of myocardial fibrosis. The fibrosis was quantitated by determination of myocardial hydroxyproline concentrations (MHP). MHP concentration in the untreated, irradiated rabbits was greater than in those treated with MP (p less than 0.05) or IB (p less than 0.01) and in the untreated, unirradiated rabbits (p less than 0.01). Early administration of MP or IB retarded the development of myocardial fibrosis, pericarditis and pericardial effusion, and improved survival in this experimental model of radiation-induced heart disease.

  2. Myocardial hydroxyproline reduced by early administration of methylprednisolone or ibuprofen to rabbits with radiation-induced heart disease

    SciTech Connect

    Reeves, W.C.; Cunningham, D.; Schwiter, E.J.; Abt, A.; Skarlatos, S.; Wood, M.A.; Whitesell, L.

    1982-05-01

    The ability of methylprednisolone (MP) and ibuprofen (IB) to reduce the severity of the late state of radiation-induced heart disease was assessed in 57 New Zealand white rabbits. Before and shortly after cardiac irradiation, 15 rabbits received i.v. MP, 30 mg/kg twice daily for 3 days, and 15 others received IB, 12.5 mg/kg twice daily for 2 days. No drug administered to 14 irradiated rabbits, and neither irradiation nor drugs were administered to 13 rabbits that served as controls. All 15 rabbits treated with MP and 13 of the 15 treated with IB lived for 100 days. Only seven of the untreated, irradiated rabbits lived that long. Longevity of each treated group of rabbits was better (p < 0.01 and 0.05) than that of the untreated, irradiated rabbits. Surviving rabbits were killed 100 days after irradiation. Pericarditis (p < 0.05) and pericardial effusion (p < 0.01) were less frequent in the treated, irradiated groups than in the untreated, irradiated rabbits. At least some rabbits in each irradiated group had microscopic evidence of myocardial fibrosis. The fibrosis was quantitated by determination of myocardial hydroxyproline concentrations (MHP). MHP concentration in the untreated, irradiated rabbits was greater than in those treated with MP (p < 0.05) or IB (p < 0.01) and in the untreated, unirradiated rabbits (p < 0.01). Early administrative of MP or IB retarded the development of myocardial fibrosis, pericarditis and pericardial effusin, and improved survival in this experimental model of radiation-induced heart disease.

  3. Pneumatic Proboscis Heat-Flow Probe

    NASA Technical Reports Server (NTRS)

    Zacny, Kris; Hedlund, Magnus; Mumm, Eric; Shasho, Jeffrey; Chu, Philip; Kumar, Nishant

    2013-01-01

    Heat flow is a fundamental property of a planet, and provides significant constraints on the abundance of radiogenic isotopes, the thermal evolution and differentiation history, and the mechanical properties of the lithosphere. Heat-flow measurements are also essential in achieving at least four of the goals set out by the National Research Council for future lunar exploration. The heat-flow probe therefore directly addresses the goal of the Lunar Geophysical Network, which is to understand the interior structure and composition of the Moon. A key challenge for heat flow measurement is to install thermal sensors to the depths approximately equal to 3 m that are not influenced by the diurnal, annual, and longer-term fluctuations of the surface thermal environment. In addition, once deployed, the heat flow probe should cause little disturbance to the thermal regime of the surrounding regolith. A heat-flow probe system was developed that has two novel features: (1) it utilizes a pneumatic (gas) approach, excavates a hole by lofting the lunar soil out of the hole, and (2) deploys the heat flow probe, which utilizes a coiled up tape as a thermal probe to reach greater than 3-meter depth. The system is a game-changer for small lunar landers as it exhibits extremely low mass, volume, and simple deployment. The pneumatic system takes advantage of the helium gas used for pressurizing liquid propellant of the lander. Normally, helium is vented once the lander is on the surface, but it can be utilized for powering pneumatic systems. Should sufficient helium not be available, a simple gas delivery system may be taken specifically for the heat flow probe. Either way, the pneumatic heat flow probe system would be much lighter than other systems that entirely rely on the electrical power of the lander.

  4. Development of the prototype pneumatic transfer system for ITER neutron activation system.

    PubMed

    Cheon, M S; Seon, C R; Pak, S; Lee, H G; Bertalot, L

    2012-10-01

    The neutron activation system (NAS) measures neutron fluence at the first wall and the total neutron flux from the ITER plasma, providing evaluation of the fusion power for all operational phases. The pneumatic transfer system (PTS) is one of the key components of the NAS for the proper operation of the system, playing a role of transferring encapsulated samples between the capsule loading machine, irradiation stations, counting stations, and disposal bin. For the validation and the optimization of the design, a prototype of the PTS was developed and capsule transfer tests were performed with the developed system.

  5. An electromagnetic pneumatic blood pump driver.

    PubMed

    Whalen, R L; Briskman, R N

    1988-01-01

    An electromagnetic pneumatic pump driver has been developed with the goals of enhanced mechanical reliability and simplicity of operation. The new driver eliminates failure prone components such as solenoid valves or pressure regulators common to conventional pneumatic drive systems, has only a single moving part, and provides for closed-loop operation in which stroke volume and dP/dT are controlled on each beat in real time. Power is provided by a high force (178 N) electromagnetic linear actuator. This assembly uses a high energy density neodymium-iron-boron permanent magnet, low loss vanadium alloy pole pieces, and an energized moving coil. The nominal stroke length of the actuator is 1.7 cm. During operation, the moving coil always remains within a fixed annular air gap, resulting in a measured force output versus applied power linearity of better than 92% over its stroke range. The coil is directly attached to the free end of a 10 cm diameter, 21 convolution, welded titanium metal bellows that forms the gas containing element of the system. The comparatively low pressure gradients across the bellows in this application result in a predicted life for the bellows in excess of 10(9) cycles. Bellows position and internal pressure are monitored continuously to control the pneumatic output. The linear actuator total excursion and velocity are adjusted on each beat using a closed-loop servo system. This results in a pump driver with no operator required adjustment of drive pressure. Instead, there are user selected settings of stroke volume, operating mode, and fill sensitivity.(ABSTRACT TRUNCATED AT 250 WORDS)

  6. 49 CFR 236.837 - Valve, electro-pneumatic.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Valve, electro-pneumatic. 236.837 Section 236.837 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION... Valve, electro-pneumatic. A valve electrically operated which, when operated, will permit or...

  7. 49 CFR 236.837 - Valve, electro-pneumatic.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 4 2011-10-01 2011-10-01 false Valve, electro-pneumatic. 236.837 Section 236.837 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION... Valve, electro-pneumatic. A valve electrically operated which, when operated, will permit or...

  8. Web-Based Learning and Instruction Support System for Pneumatics

    ERIC Educational Resources Information Center

    Yen, Chiaming; Li, Wu-Jeng

    2003-01-01

    This research presents a Web-based learning and instructional system for Pneumatics. The system includes course material, remote data acquisition modules, and a pneumatic laboratory set. The course material is in the HTML format accompanied with text, still and animated images, simulation programs, and computer aided design tools. The data…

  9. Evaluation of neutron flux parameters in irradiation sites of research reactor using the Westcott-formalism for the k0 neutron activation analysis method

    NASA Astrophysics Data System (ADS)

    Kasban, H.; Hamid, Ashraf

    2015-12-01

    Instrumental Neutron Activation Analysis using k0 (k0-INAA) method has been used to determine a number of elements in sediment samples collected from El-Manzala Lake in Egypt. k0-INAA according to Westcott's formalism has been implemented using the complete irradiation kit of the fast pneumatic rabbit and some selected manually loaded irradiation sites for short and long irradiation at Egypt Second Research Reactor (ETRR-2). Zr-Au and Co sets as neutron flux monitors are used to determine the neutron flux parameters (f and α) in each irradiation sites. Two reference materials IAEA Soil-7 samples have been inserted and implemented for data validation and an internal monostandard multi monitor used (k0 based IM-NAA). It was given a good agreement between the experimental analyzed values and that obtained of the certified values. The major and trace elements in the sediment samples have been evaluated with the use of Co as an internal and Au as an external monostandard comparators. The concentrations of the elements (Cr, Mn and Zn) in the sediment samples of the present work are discussed regarding to those obtained from other sites.

  10. Traction of Pneumatic Tires on Wet Runways

    NASA Technical Reports Server (NTRS)

    Horne, Walter B.; Joyner, Upshur T.

    1965-01-01

    Recent work on the traction of pneumatic tires on wet runways is discussed, and it is shown that a loss of tire traction adversely affects cross-wind landings. The effect of runway surface texture is discussed,, and a simple method for measuring surface texture is described. A preliminary correlation of tire traction with surface texture is shown. Results of work at Langley Research Center on the use of air jets to improve tire traction on wet or flooded runways indicate that this is a promising approach for alleviating the large losses in tire braking and sideways traction that occur when tire hydroplaning occurs on a flooded runway.

  11. Revisiting Pneumatic Nail Gun Trigger Recommendations

    PubMed Central

    Albers, James; Lipscomb, Hester; Hudock, Stephen; Dement, John; Evanoff, Bradley; Fullen, Mark; Gillen, Matt; Kaskutas, Vicki; Nolan, James; Patterson, Dennis; Platner, James; Pompeii, Lisa; Schoenfisch, Ashley

    2015-01-01

    Summary Use of a pneumatic nail gun with a sequential actuation trigger (SAT) significantly diminishes the risk for acute traumatic injury compared to use of a contact actuation trigger (CAT) nail gun. A theoretically-based increased risk of work-related musculoskeletal disorders from use of a SAT nail gun, relative to CAT, appears unlikely and remains unproven. Based on current knowledge, the use of CAT nail guns cannot be justified as a safe alternative to SAT nail guns. This letter provides a perspective of ergonomists and occupational safety researchers recommending the use of the sequential actuation trigger for all nail gun tasks in the construction industry. PMID:26366020

  12. Pneumatic transport of coal by steam

    SciTech Connect

    Ekmann, J.M.; Wildman, D.J.; Mathur, M.P.; Klinzing, G.E.

    1985-01-01

    Steam has been suggested as the transport gas in power plant facilities where the availability high pressure steam already exists. The transport of coal pneumatically by the use of steam to a loading ratio of 10 has been studied experimentally in a 0.0107 meter diameter pipe. Analysis of the energy losses in transport of the steam-coal mixture has been carried out using a model based on thermodynamic and fluid mechanics principles. Good agreement between the data and model has been obtained.

  13. Pneumatic transport of coal by steam

    SciTech Connect

    Wildman, D.J.; Mathur, M.P.; Ekmann, J.M.; Klinzing, G.E.

    1984-01-01

    Steam has been suggested as the transport gas in power plant facilities where the availability of high pressure steam already exists. The transport of coal pneumatically by the use of steam to a loading ratio of 10 has been studied experimentally in a 3/8'' pipe. Analysis of the energy losses in transport of the steam-coal mixture has been carried out using a model based on thermodynamic and fluid mechanics principles. Good agreement between the data and model has been obtained. 4 references, 2 figures.

  14. Pneumatic tire-based piezoelectric power generation

    NASA Astrophysics Data System (ADS)

    Makki, Noaman; Pop-Iliev, Remon

    2011-03-01

    Plug-in Hybrid Electric Vehicles (PHEVs) and Extended Range Electric Vehicles (EREVs) currently mainly rely on Internal Combustion Engines (ICE) utilizing conventional fuels to recharge batteries in order to extend their range. Even though Piezo-based power generation devices have surfaced in recent years harvesting vibration energy, their output has only been sufficient to power up sensors and other such smaller devices. The permanent need for a cleaner power generation technique still remains. This paper investigates the possibility of using piezoceramics for power generation within the vehicle's wheel assembly by exploiting the rotational motion of the wheel and the continuously variable contact point between the pneumatic tire and the road.

  15. A comparison between two pneumatic suspension architectures

    NASA Astrophysics Data System (ADS)

    Quaglia, G.; Scopesi, M.; Franco, W.

    2012-04-01

    The aim of this work is to assess and compare the mathematical models of two pneumatic suspension architectures and show how they can converge, after appropriate simplifications, to a general linear form. After making this model dimensionless, it will be used to study, with a transmissibility analysis, the behaviour of a mono-suspension (quarter-car model). Finally, an example of a design process will be shown to highlight the strengths and weaknesses of both architectures and to provide the reader with a practical design tool.

  16. Anatomical Factors Influencing Pneumatization of the Petrous Apex

    PubMed Central

    Kim, Min-Ju; Lee, Seunghun; Choi, Hana

    2015-01-01

    Objectives Aim of the present study was to define the relationship between petrous apex pneumatization and the nearby major anatomical landmarks using temporal bone computed tomography (CT) images. Methods This retrospective, Institutional Review Board-approved study analyzed CT images of 84 patients that showed normal findings bilaterally. Pneumatization of the petrous apex was classified using two methods. Eight parameters were as follows: angle between the posterior cranial fossa and internal auditory canal, Morimitsu classification of anterior epitympanic space, distance between the carotid canal and jugular bulb, distance between the cochlear modiolus and carotid canal, distance between the tympanic segment and jugular bulb, high jugular bulb, distance between the vertical segment and jugular bulb, and distance between the lateral semicircular canals and middle cranial fossa. Results There was a significant difference in Morimitsu classification of the anterior epitympanic space between the two classification methods. Poorly pneumatic upper petrous apices were distributed uniformly in three types of Morimitsu classification, but more pneumatic upper petrous apices were found more often in anterior type. Lower petrous apex was well pneumatized regardless of the types of anterior epitympanic space, but the largest amount of pneumatization was found more frequently in the anterior type of anterior epitympanic space. Conclusion This study showed that there was no reliable anatomic marker to estimate petrous apex pneumatization and suggests that the pneumatization of the petrous apex may be an independent process from other part of the temporal bone, and may not be influenced by the nearby major anatomical structures in the temporal bone. In this study, the anterior type of anterior epitympanic space was found to be closely related to more well-pneumatized petrous apices, which implies that the anterior saccule of the saccus medius may be the main factor

  17. Stacked pneumatic cylinders automate conveyor belt operations

    SciTech Connect

    Thornton, G.

    1982-11-01

    Shows how clusters of remotely controlled pneumatic cylinders swing a hinged conveyor belt to 4 preselected vertical positions. Using a manual method to move the conveyor meant that the operator had to use a hand winch, sheaves, drums, and winch cable. There was a need to develop a simple, effective, and remotely controlled system which would perform 2 functions: eliminate the need for stopping the conveyor to reset the hinged belt, and not require the operator to leave the master control console. Using the developed system, the operator need only turn on the appropriate switching valves from the master console. Each pneumatic cylinder is actuated in sequence, on the retraction stroke only, through the elevating positions. To lower the conveyor belt, the head end of each cylinder is exhausted; the weight of the belt extends the cylinders, lowering the belt by gravity. Cylinder exhaust ports in the power valves are fitted with adjustable flow control valves to regulate cylinder speed; common exhaust ports in the interconnected manifolds are fitted with air silencers.

  18. Axial and appendicular pneumaticity in Archaeopteryx.

    PubMed Central

    Christiansen, P; Bonde, N

    2000-01-01

    From the time of its discovery in 1860 to this day Archaeopteryx has been essential to our understanding of avian evolution. Despite the great diversity of plesiomorphic avialan (sensu Gauthier 1986) taxa discovered within the last decade, Archaeopteryx remains the most basal avialan taxon. A very unusual feature of extant birds is their lung structure, in which air diverticulae penetrate the bones. This has previously been reported in Archaeopteryx as well, in the cervical vertebrae of the Berlin specimen and in an anterior thoracal vertebra of the Eichstätt specimen. This indicates the presence of a cervical air sac. We show that the London specimen also has pneumatized anterior thoracal vertebrae, and, thus, that this feature was present in the most archaic avialans, as the London and Eichstätt specimens are different species. Furthermore, the pelvis of the London specimen shows clear signs of the presence of an abdominal air sac, indicating that at least two of the five air sacs present in modern birds were also present in Archaeopteryx. Evidence of pubic pneumaticity was also found in the same position in some extant ratites. PMID:11197125

  19. Transforming insect electromyograms into pneumatic muscle control

    NASA Astrophysics Data System (ADS)

    Rutter, Brandon; Mu, Laiyong; Ritzmann, Roy; Quinn, Roger

    2006-05-01

    Robots can serve as hardware models for testing biological hypotheses. Both for this reason and to improve the state of the art of robotics, we strive to incorporate biological principles of insect locomotion into robotic designs. Previous research has resulted in a line of robots with leg designs based on walking and climbing movements of the cockroach Blaberus discoidalis. The current version, Robot V, uses muscle-like Braided Pneumatic Actuators (BPAs). In this paper, we use recorded electromyograms (EMGs) to drive robot joint motion. A muscle activation model was developed that transforms EMGs recorded from behaving cockroaches into appropriate commands for the robot. The transform is implemented by multiplying the EMG by an input gain thus generating an input pressure signal, which is used to drive a one-way closed loop pressure controller. The actuator then can be modeled as a capacitance with input rectification. The actuator exhaust valve is given a leak rate, making the transform a leaky integrator for air pressure, which drives the output force of the actuator. We find parameters of this transform by minimizing the difference between the robot motion produced and that observed in the cockroach. Although we have not reproduced full-amplitude cockroach motion using this robot, results from evaluation on reduced-amplitude cockroach angle data strongly suggest that braided pneumatic actuators can be used as part of a physical model of a biological system.

  20. Continued Development and Improvement of Pneumatic Heavy Vehicles

    SciTech Connect

    Robert J. Englar

    2005-07-15

    The objective of this applied research effort led by Georgia Tech Research Institute is the application of pneumatic aerodynamic technology previously developed and patented by us to the design of an appropriate Heavy Vehicle (HV) tractor-trailer configuration, and experimental confirmation of this pneumatic configuration's improved aerodynamic characteristics. In Phases I to IV of our previous DOE program (Reference 1), GTRI has developed, patented, wind-tunnel tested and road-tested blown aerodynamic devices for Pneumatic Heavy Vehicles (PHVs) and Pneumatic Sports Utility Vehicles (PSUVs). To further advance these pneumatic technologies towards HV and SUV applications, additional Phase V tasks were included in the first year of a continuing DOE program (Reference 2). Based on the results of the Phase IV full-scale test programs, these Phase V tasks extended the application of pneumatic aerodynamics to include: further economy and performance improvements; increased aerodynamic stability and control; and safety of operation of Pneumatic HVs. Continued development of a Pneumatic SUV was also conducted during the Phase V program. Phase V was completed in July, 2003; its positive results towards development and confirmation of this pneumatic technology are reported in References 3 and 4. The current Phase VI of this program was incrementally funded by DOE in order to continue this technology development towards a second fuel economy test on the Pneumatic Heavy Vehicle. The objectives of this current Phase VI research and development effort (Ref. 5) fall into two categories: (1) develop improved pneumatic aerodynamic technology and configurations on smaller-scale models of the advanced Pneumatic Heavy Vehicle (PHV); and based on these findings, (2) redesign, modify, and re-test the modified full-scale PHV test vehicle. This second objective includes conduct of an on-road preliminary road test of this configuration to prepare it for a second series of SAE Type-U fuel

  1. 46 CFR 108.409 - Location and spacing of tubing in pneumatic fire detection system.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Location and spacing of tubing in pneumatic fire... and spacing of tubing in pneumatic fire detection system. (a) All tubing in a pneumatic fire detection... exposed in the space. (c) A pneumatic fire detection system must be set to activate after approximately...

  2. Solid target irradiation and transfer system

    NASA Astrophysics Data System (ADS)

    Gelbart, W.; Johnson, R. R.; Abeysekera, B.

    2012-12-01

    A compact, fully automated solid target irradiation, handling and transfer system was developed for the 100Mo/99m Tc production; however, it can be used for any solid target material. All the target handling is fully automated. The target is pneumatically transferred to the irradiation station where it is removed from the carrier, placed in the irradiation chamber and the cooling water connected. At the end of irradiation the target is returned to the carrier and transferred to the processing hot cell where it is automatically placed in a distillation unit. 100 Mo targets are prepared by plasma spraying or laser cladding of the copper target.

  3. Prescription diets for rabbits.

    PubMed

    Proença, Laila Maftoum; Mayer, Jörg

    2014-09-01

    Dietary management can be used with drug therapy for the successful treatment of many diseases. Therapeutic nutrition is well-recognized in dogs and cats and is beginning to increase among other pet species, including rabbits. The nutritional component of some rabbit diseases (eg, urolithiasis) is not completely understood, and the clinician should evaluate the use of prescription diets based on the scientific literature and individual needs. Long-term feeding trials are needed to further evaluate the efficacy of prescription diets in rabbits. Prescription diets are available for selected diseases in rabbits, including diets for immediate-term, short-term, and long-term management. PMID:25155667

  4. Pneumatic pump actuator for oil wells

    SciTech Connect

    Klaeger, J.H.

    1991-07-16

    This patent describes a pneumatic pump actuator. It comprises a power cylinder having a sucker rod passing therethrough; a piston mounted to the sucker rod for reciprocation inside the power cylinder; means for selectively routing relatively high pressure air or gas into the power cylinder on a first and both the first and a second side of the piston; a floating piston bleeder valve shiftable from a first to a second piston and back to the first position for supplying air or gas to the routing means and on to the first or the first and second sides of the piston; first and second pivot arms mounted near the ends of the bleeder valve; first and second activator buttons on the ends of the bleeder valve for shifting the bleeder valve when engaged by the respective first and second pivot arms from the first position to the second position and back to the first position; first and second contactors.

  5. Optimizing pneumatic conveying of biomass materials

    NASA Astrophysics Data System (ADS)

    DiCianni, Matthew Edward Michael

    2011-12-01

    Biomass is a readily available but underutilized energy resource. One of the main challenges is the inability of biomass feed stocks like corn stover or wood chips to flow freely without intermittent jamming. This research integrated an automated pneumatic conveying system to efficiently transport biomass into a biomass reactor. Material was held in a storage container until an end effector attached to a 3-axis controller engaged the material to flow through pneumatic vacuum in the carrier fluid of air. The material was disengaged from the carrier fluid through centripetal forces induced by a cyclone separator. As the air was pulled out of the cyclone, the biomass drops out the bottom due to gravitational forces and fell into a secondary storage hopper. The second storage container was for testing purposes only, where the actual apparatus would use a vertically oriented lock hopper to feed material into the biomass reactor. In the experimental test apparatus, sensors measured the storage hopper weight (mass-flow rate), pressure drop from the blower, and input power consumption of the motor. Parameters that were adjusted during testing include pipe diameter, material type, and motor speed. Testing indicated that decreasing the motor speed below its maximum still allows for conveyance of the material without blockage forming in the piping. The data shows that the power consumption of the system can be reduced based on the size and weight of the material introduced to the conveying pipe. Also, conveying certain materials proved to be problematic with particular duct diameters. Ultimately, an optimal duct diameter that can perform efficiently for a broad range of materials was chosen for the given system. Through these improvements, the energy return on investment will be improved for biomass feed stocks, which is taking a step in the right direction to secure the nation's energy independence.

  6. Dry ice plug for hydraulic and pneumatic pipe flushing

    NASA Technical Reports Server (NTRS)

    Francino, L.; Rauch, S.

    1972-01-01

    Development of technique to clear blockages in hydraulic and pneumatic pipes is discussed. Technique consists of using dry ice plug to separate sensitive components from flushing fluid. Diagram of equipment and principles of operation are presented.

  7. Detail, north end of console and pneumatic tube message port, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Detail, north end of console and pneumatic tube message port, also showing mirror to reflect view of communications switchboard - March Air Force Base, Strategic Air Command, Combat Operations Center, 5220 Riverside Drive, Moreno Valley, Riverside County, CA

  8. 23. CORE WORKER OPERATING A COREBLOWER THAT PNEUMATICALLY FILLED CORE ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    23. CORE WORKER OPERATING A CORE-BLOWER THAT PNEUMATICALLY FILLED CORE BOXES WITH RESIGN IMPREGNATED SAND AND CREATED A CORE THAT THEN REQUIRED BAKING, CA. 1950. - Stockham Pipe & Fittings Company, 4000 Tenth Avenue North, Birmingham, Jefferson County, AL

  9. Spot-Welding Gun With Adjustable Pneumatic Spring

    NASA Technical Reports Server (NTRS)

    Burley, Richard K.

    1990-01-01

    Proposed spot-welding gun equipped with pneumatic spring, which could be bellows or piston and cylinder, exerts force independent of position along stroke. Applies accurate controlled force to joint welded, without precise positioning at critical position within stroke.

  10. PNEUMATICALLY CLEANING TOP HALF OF LARGE MOLD IN BOX FLOOR ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    PNEUMATICALLY CLEANING TOP HALF OF LARGE MOLD IN BOX FLOOR AREA TO REMOVE ANY EXCESS OR LOOSE SAND. - Stockham Pipe & Fittings Company, Ductile Iron Foundry, 4000 Tenth Avenue North, Birmingham, Jefferson County, AL

  11. Inline evenflow material distributor for pneumatic material feed systems

    DOEpatents

    Thiry, Michael J.

    2007-02-20

    An apparatus for reducing clogs in a pneumatic material feed line, such as employed in abrasive waterjet machining systems, by providing an evenflow feed of material therethrough. The apparatus preferably includes a hollow housing defining a housing volume and having an inlet capable of connecting to an upstream portion of the pneumatic material feed line, an outlet capable of connecting to a downstream portion of the pneumatic material feed line, and an air vent located between the inlet and outlet for venting excess air pressure out from the housing volume. A diverter, i.e. an impingement object, is located at the inlet and in a path of incoming material from the upstream portion of the pneumatic material feed line, to break up clumps of ambient moisture-ridden material impinging on the diverter. And one or more filter screens is also preferably located in the housing volume to further break up clumps and provide filtering.

  12. Radiation induced gram negative bacteremia and endotoxemia in rabbits: modification by anti-lipopolysaccharide hyperimmune equine plasma

    SciTech Connect

    Well, M.T.; Gaffin, S.L.; Jordaan, J.P.

    1987-06-29

    Lethal whole-body irradiation damages the gut mucosa and leads to leakage of endotoxin or lipopolysaccharides (LPS) into the systemic circulation. Sixteen rabbits, irradiated with 900 rads /sup 60/Co, were randomly divided on day 4 into 2 groups, one of which received an intraperitoneal injection of normal saline (control) and the other (experimental) an equal volume of anti-LPS hyperimmune plasma. The time course of endotoxemia and bacteremia were determined for the duration of the experiment. While rabbits in both groups died within 13 days after irradiation, rabbits given saline died on average 2 days earlier, than rabbits given anti-LPS plasma. Plasma LPS concentrations rose to a small peak on day 2 prior to treatment. Thereafter plasma LPS in rabbits given saline increased forty fold by day 9. In contrast, in rabbits given anti-LPS plasma, LPS concentrations in the plasma remained within pretreatment limits. By day 12 after irradiation, plasma anti-LPS IgG had declined to 5.8% of pretreatment levels in rabbits given saline as compared to 46% in rabbits given anti-LPS plasma (p 0.005). While both groups developed gram-positive bacteremia, rabbits given saline in addition also developed gram-negative bacteremia. No rabbits treated with Anti-LPS showed gram-negative bacteremia.

  13. Pneumatic Regolith Transfer Systems for In Situ Resource Utilization

    NASA Technical Reports Server (NTRS)

    Mueller, R. P.; Townsend, I. I.; Mantovani, J. G.; Zacny, Kris A.; Craft, Jack

    2010-01-01

    This slide presentation reviews the testing of a pneumatic system for transfering regolith, to be used for In Situ Resource Utilization (ISRU). Using both the simulated microgravity of parabolic flight and ground testing, the tests demonstrated that lunar regolith can be conveyed pneumatically into a simulated ISRU oxygen production plant reactor. The ground testing also demonstrated that the regolith can be expelled from the ISRU reactor for disposal or for other resource processing.

  14. High-Torque, Lightweight, Pneumatically Driven Wrench For Small Spaces

    NASA Technical Reports Server (NTRS)

    Miller, Thomas W.

    1995-01-01

    Pneumatically driven wrench provides torque up to 3,000 lb. per ft. in small space. Designed to reach into 2.6 x 2.75 x 6 in. pocket. Weighs approximately 25 lbs. Includes reversible pneumatic motor (electric motor could be used instead) and slip clutch. Also includes device indicating total angle through which wrench turned bolt or nut. This feature used for turn-of-the-nut tightening method.

  15. A New Type of Motor: Pneumatic Step Motor

    PubMed Central

    Stoianovici, Dan; Patriciu, Alexandru; Petrisor, Doru; Mazilu, Dumitru; Kavoussi, Louis

    2011-01-01

    This paper presents a new type of pneumatic motor, a pneumatic step motor (PneuStep). Directional rotary motion of discrete displacement is achieved by sequentially pressurizing the three ports of the motor. Pulsed pressure waves are generated by a remote pneumatic distributor. The motor assembly includes a motor, gearhead, and incremental position encoder in a compact, central bore construction. A special electronic driver is used to control the new motor with electric stepper indexers and standard motion control cards. The motor accepts open-loop step operation as well as closed-loop control with position feedback from the enclosed sensor. A special control feature is implemented to adapt classic control algorithms to the new motor, and is experimentally validated. The speed performance of the motor degrades with the length of the pneumatic hoses between the distributor and motor. Experimental results are presented to reveal this behavior and set the expectation level. Nevertheless, the stepper achieves easily controllable precise motion unlike other pneumatic motors. The motor was designed to be compatible with magnetic resonance medical imaging equipment, for actuating an image-guided intervention robot, for medical applications. For this reason, the motors were entirely made of nonmagnetic and dielectric materials such as plastics, ceramics, and rubbers. Encoding was performed with fiber optics, so that the motors are electricity free, exclusively using pressure and light. PneuStep is readily applicable to other pneumatic or hydraulic precision-motion applications. PMID:21528106

  16. A New Type of Motor: Pneumatic Step Motor.

    PubMed

    Stoianovici, Dan; Patriciu, Alexandru; Petrisor, Doru; Mazilu, Dumitru; Kavoussi, Louis

    2007-02-01

    This paper presents a new type of pneumatic motor, a pneumatic step motor (PneuStep). Directional rotary motion of discrete displacement is achieved by sequentially pressurizing the three ports of the motor. Pulsed pressure waves are generated by a remote pneumatic distributor. The motor assembly includes a motor, gearhead, and incremental position encoder in a compact, central bore construction. A special electronic driver is used to control the new motor with electric stepper indexers and standard motion control cards. The motor accepts open-loop step operation as well as closed-loop control with position feedback from the enclosed sensor. A special control feature is implemented to adapt classic control algorithms to the new motor, and is experimentally validated. The speed performance of the motor degrades with the length of the pneumatic hoses between the distributor and motor. Experimental results are presented to reveal this behavior and set the expectation level. Nevertheless, the stepper achieves easily controllable precise motion unlike other pneumatic motors. The motor was designed to be compatible with magnetic resonance medical imaging equipment, for actuating an image-guided intervention robot, for medical applications. For this reason, the motors were entirely made of nonmagnetic and dielectric materials such as plastics, ceramics, and rubbers. Encoding was performed with fiber optics, so that the motors are electricity free, exclusively using pressure and light. PneuStep is readily applicable to other pneumatic or hydraulic precision-motion applications. PMID:21528106

  17. Acoustic characterization of pneumatic percussion tools

    NASA Astrophysics Data System (ADS)

    Muract, Jorge; Kadam, Rahul; Burdisso, Ricardo; Johnson, Marty

    2005-09-01

    Pneumatic powered percussion tools are extensively used in construction industry. They are one of the noisiest machines in the construction industry generating noise levels well above 110 dBA which are well beyond the permissible exposure limit (PEL) of 85 dBA. The paper presents comprehensive analysis of the noise generated from these percussion tools. Noise tests were carried out on different percussion tools ranging from small chipping hammers to rock drills from two major construction equipment manufacturing companies. These tests were carried out in an anechoic room as well as in simulated operating conditions to determine the overall sound power levels. A spherical array of microphones was used to obtain an accurate estimate of the overall sound power levels and the directivity. The overall sound power radiation was found to be in the range of 105-115 dBA. An advanced 63 microphone phased array was used to successfully locate and identify the major sources of noise from these tools. The outcome of the tests is illustrated in detail in the paper. Further the paper will suggest noise control methods to reduce overall sound power radiation and discuss potential performance levels.

  18. Photodynamic therapy for implanted VX2 tumor in rabbit brains

    NASA Astrophysics Data System (ADS)

    Li, Fei; Feng, Hua; Lin, Jiangkai; Zhu, Gang; Chen, Zhi; Li, Cong-yan

    2005-07-01

    To evaluate the therapeutic effect and the safety of single photodynamic therapy (PDT) with hematoporphyrin derivative produced in China, 60 New Zealand adult rabbits with VX2 tumor implanted into the brain were divided randomly into non-PDT-group and PDT-group. 36 rabbits of the PDT-group were performed photodynamic therapy. The survival time, neurological deteriorations, intracranial pressure (ICP), histology, pathology, tumor volume and brain water content were measured. Other 12 rabbits were received hematoporphyrin derivative and light irradiation of the normal brain. The ICP, histology, pathology, and brain water content were measured. The result indicated that Simple PDT may elongate the average survival time of the rabbits with VX2 tumors significantly; kill tumor cells; cause transient brain edema and increase ICP, but it is safe to be used in treating brain tumor.

  19. Killer cell lines against Shope carcinoma cells in rabbits.

    PubMed

    Takahashi, M; Yamade, I; Seto, A

    1991-09-01

    Killer cell activity against Shope carcinoma cells was not detected in PBL nor in spleen cells from tumor-bearing B/J rabbits, but was induced by in vitro culture of these cells in the presence of IL-2 and X-irradiated carcinoma cells. HTLV-I-transformed killer cell lines were successfully obtained by the culturing of PBL from an HTLV-I-infected and tumor-bearing Chbb:HM rabbit. These killer cells included large cells with azurophilic granules in the cytoplasm and with a reniform nucleus, thus resembling large granular lymphocytes. The killer activity was similar against the Vx2K cell line from a random-bred rabbit and SCB cell lines from an B/J rabbit, suggesting the absence of MHC restriction. PMID:1655241

  20. Mechanical implications of pneumatic neck vertebrae in sauropod dinosaurs

    PubMed Central

    Schwarz-Wings, Daniela; Meyer, Christian A.; Frey, Eberhard; Manz-Steiner, Hans-Rudolf; Schumacher, Ralf

    2010-01-01

    The pre-sacral vertebrae of most sauropod dinosaurs were surrounded by interconnected, air-filled diverticula, penetrating into the bones and creating an intricate internal cavity system within the vertebrae. Computational finite-element models of two sauropod cervical vertebrae now demonstrate the mechanical reason for vertebral pneumaticity. The analyses show that the structure of the cervical vertebrae leads to an even distribution of all occurring stress fields along the vertebrae, concentrated mainly on their external surface and the vertebral laminae. The regions between vertebral laminae and the interior part of the vertebral body including thin bony struts and septa are mostly unloaded and pneumatic structures are positioned in these regions of minimal stress. The morphology of sauropod cervical vertebrae was influenced by strongly segmented axial neck muscles, which require only small attachment areas on each vertebra, and pneumatic epithelia that are able to resorb bone that is not mechanically loaded. The interaction of these soft tissues with the bony tissue of the vertebrae produced lightweight, air-filled vertebrae in which most stresses were borne by the external cortical bone. Cervical pneumaticity was therefore an important prerequisite for neck enlargement in sauropods. Thus, we expect that vertebral pneumaticity in other parts of the body to have a similar role in enabling gigantism. PMID:19801376

  1. Modeling the dynamic characteristics of pneumatic muscle.

    PubMed

    Reynolds, D B; Repperger, D W; Phillips, C A; Bandry, G

    2003-03-01

    A pneumatic muscle (PM) system was studied to determine whether a three-element model could describe its dynamics. As far as the authors are aware, this model has not been used to describe the dynamics of PM. A new phenomenological model consists of a contractile (force-generating) element, spring element, and damping element in parallel. The PM system was investigated using an apparatus that allowed precise and accurate actuation pressure (P) control by a linear servo-valve. Length change of the PM was measured by a linear potentiometer. Spring and damping element functions of P were determined by a static perturbation method at several constant P values. These results indicate that at constant P, PM behaves as a spring and damper in parallel. The contractile element function of P was determined by the response to a step input in P, using values of spring and damping elements from the perturbation study. The study showed that the resulting coefficient functions of the three-element model describe the dynamic response to the step input of P accurately, indicating that the static perturbation results can be applied to the dynamic case. This model is further validated by accurately predicting the contraction response to a triangular P waveform. All three elements have pressure-dependent coefficients for pressure P in the range 207 < or = P < or = 621 kPa (30 < or = P < or = 90 psi). Studies with a step decrease in P (relaxation of the PM) indicate that the damping element coefficient is smaller during relaxation than contraction.

  2. A Pneumatic Actuated Microfluidic Beads-Trapping Device

    SciTech Connect

    Shao, Guocheng; Cai, Ziliang; Wang, Jun; Wang, Wanjun; Lin, Yuehe

    2011-08-20

    The development of a polydimethylsiloxane (PDMS) microfluidic microbeads trapping device is reported in this paper. Besides fluid channels, the proposed device includes a pneumatic control chamber and a beads-trapping chamber with a filter array structure. The pneumatic flow control chamber and the beads-trapping chamber are vertically stacked and separated by a thin membrane. By adjusting the pressure in the pneumatic control chamber, the membrane can either be pushed against the filter array to set the device in trapping mode or be released to set the device in releasing mode. In this paper, a computational fluid dynamics simulation was conducted to optimize the geometry design of the filter array structure; the device fabrication was also carried out. The prototype device was tested and the preliminary experimental results showed that it can be used as a beads-trapping unit for various biochemistry and analytical chemistry applications, especially for flow injection analysis systems.

  3. Model analysis of mechanisms controlling pneumatic soil vapor extraction.

    PubMed

    Høier, C K; Sonnenborg, T O; Jensen, K H; Gudbjerg, J

    2009-01-26

    The efficiency of traditional soil venting or soil vapor extraction (SVE) highly depends on the architecture of the subsurface because imposed advective air flow tends to bypass low-permeable contaminated areas. Pneumatic SVE is a technique developed to enhance remediation efficiency of heterogeneous soils by enforcing large fluctuating pressure fronts through the contaminated area. Laboratory experiments have suggested that pneumatic SVE considerably improves the recovery rate from low-permeable units. We have analyzed the experimental results using a numerical code and quantified the physical processes controlling the functioning of the method. A sensitivity analysis for selected boundary conditions, initial conditions and parameters was carried out to examine how the method behaves under conditions different from the experimental set-up. The simulations show that at the laboratory level the pneumatic venting technology is superior to the traditional technique, and that the method is particularly efficient in cases where large permeability contrasts exist between soil units in the subsurface. PMID:19004522

  4. 46 CFR 56.97-35 - Pneumatic tests (replaces 137.5).

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 2 2010-10-01 2010-10-01 false Pneumatic tests (replaces 137.5). 56.97-35 Section 56.97... SYSTEMS AND APPURTENANCES Pressure Tests § 56.97-35 Pneumatic tests (replaces 137.5). (a) General Requirements. When a pneumatic test is performed, it must be conducted in accordance with the requirements...

  5. 14 CFR 23.1416 - Pneumatic de-icer boot system.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Pneumatic de-icer boot system. 23.1416... Safety Equipment § 23.1416 Pneumatic de-icer boot system. If certification with ice protection provisions is desired and a pneumatic de-icer boot system is installed— (a) The system must meet...

  6. 46 CFR 54.10-15 - Pneumatic test (modifies UG-100).

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... by reference; see 46 CFR 54.01-1)). In no case shall the pneumatic test pressure exceed one and one... 46 Shipping 2 2011-10-01 2011-10-01 false Pneumatic test (modifies UG-100). 54.10-15 Section 54.10... VESSELS Inspection, Reports, and Stamping § 54.10-15 Pneumatic test (modifies UG-100). (a)...

  7. 46 CFR 56.97-35 - Pneumatic tests (replaces 137.5).

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 2 2011-10-01 2011-10-01 false Pneumatic tests (replaces 137.5). 56.97-35 Section 56.97... SYSTEMS AND APPURTENANCES Pressure Tests § 56.97-35 Pneumatic tests (replaces 137.5). (a) General Requirements. When a pneumatic test is performed, it must be conducted in accordance with the requirements...

  8. 46 CFR 128.240 - Hydraulic or pneumatic power and control-materials and pressure design.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Hydraulic or pneumatic power and control-materials and... Hydraulic or pneumatic power and control—materials and pressure design. (a) Each standard piping component (such as pipe runs, fittings, flanges, and standard valves) for hydraulic or pneumatic power and...

  9. 14 CFR 23.1416 - Pneumatic de-icer boot system.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Pneumatic de-icer boot system. 23.1416... Safety Equipment § 23.1416 Pneumatic de-icer boot system. If certification with ice protection provisions is desired and a pneumatic de-icer boot system is installed— (a) The system must meet...

  10. 46 CFR 128.240 - Hydraulic or pneumatic power and control-materials and pressure design.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 4 2011-10-01 2011-10-01 false Hydraulic or pneumatic power and control-materials and... Hydraulic or pneumatic power and control—materials and pressure design. (a) Each standard piping component (such as pipe runs, fittings, flanges, and standard valves) for hydraulic or pneumatic power and...

  11. Overall life cycle comprehensive assessment of pneumatic and electric actuator

    NASA Astrophysics Data System (ADS)

    Zhang, Yeming; Cai, Maolin

    2014-05-01

    Pneumatic actuators and electric actuators have almost been applied to all manufacturing industries. The two kinds of actuators can replace each other in most fields, such as the point to point transmission occasion and some rotating occasions. However, there are very few research results about the advantages and disadvantages of two kinds of actuators under the same working conditions so far. In this paper, a novel comprehensive assessment method, named as overall life cycle comprehensive assessment (OLCCA), is proposed for comparison and assessment of pneumatic and electric actuators. OLCCA contains mechanical properties evaluation (MPE), life cycle cost analysis based on users (LCCABOU) and life cycle environmental impact analysis (LCEIA) algorithm in order to solve three difficult problems: mechanical properties assessment, cost analysis and environmental impact assessment about actuators. The mechanical properties evaluation of actuators is a multi-objective optimization problem. The fuzzy data quantification and information entropy methods are combined to establish MPE algorithm of actuators. Two kinds of pneumatic actuators and electric actuators with similar bearing capacity and similar work stroke were taken for example to verify the correctness of MPE algorithm. The case study of MPE algorithm for actuators verified its correctness. LCCABOU for actuators is also set up. Considering cost complex structure of pneumatic actuators, public device cost even method (PDCEM) is firstly presented to solve cost division of public devices such as compressors, aftercooler, receivers, etc. LCCABOU method is also effective and verified by the three groups of pneumatic actuators and electric actuators. Finally, LCEIA model of actuators is established for the environmental impact assessment of actuators. LCEIA data collection method and model establishment procedure for actuators are also put forward. With Simapro 7, LCEIA comparison results of six actuators can be

  12. Photodynamic therapy on normal rabbit mandible

    NASA Astrophysics Data System (ADS)

    Fan, Kathleen F.; Hopper, Colin; Speight, Paul M.; Davies, Claire; Bown, Stephen G.

    1995-03-01

    Photodynamic therapy has been proposed as an intra-operative adjunct to surgical resection of tumors invading bone. To assess this, we studied the effects of PDT in normal bone. Forty- four rabbits were sensitized with Photofrin 3 mg/kg, 5-aminolaevulinic acid (ALA) 400 mg/kg, or meso-tetrahydroxyphenylchlorin (mTHPC) 0.3 mg/kg. A mandibular incisor was removed and the socket irradiated with a cylindrical diffusion fiber (630 nm Photofrin and ALA, 650 nm mTHPC, 100 J per treatment). Irradiation was given 1 or 48 hours after Photofrin, 72 hours after mTHPC, whilst 2 doses were given 2.5 and 4 hours after the first fractionated dose of ALA. The socket of the ipsilateral maxillary incisor was used as a nonirradiated control to assess healing without PDT. Other controls assessed healing after irradiation of unsensitized animals. Rabbits were killed 3, 10, and 21 days after treatment. Tooth socket healing appeared to be the same in all groups of animals with evidence of woven bone formation by 10 days. We conclude that PDT is unlikely to have any effect on healing in normal bone, which makes it suitable for treating tumors invading bone.

  13. On the growth of pneumatic foams.

    PubMed

    Karakashev, Stoyan I; Georgiev, Petyr; Balashev, Konstantin

    2013-02-01

    This work reports on the behaviour of tenacious and transient pneumatic foams produced at large range of values of gas delivery rates (or superficial velocities) and surface tensions. Experimental data from the literature and produced in the course of this study were processed and analyzed. The tenacious foams were stabilized via Polyoxiethylene-2 sulfate (SDP(2)S) in presence of 0.024M NaCl and 0.003M AlCl(3) ( CMC = 1.83×10(-2) M) in the concentration range of 3.33×10(-3) M to 3.8×10(-2) M (0.18CMC -2.08CMC corresponding to values of the dynamic surface tension in the range of 42.7mN/m to 37.5mN/m. The range of gas delivery rates was from 20.5ml/min to 482.8ml/min. It was found out that the rate of foam generation coincides with the gas delivery rate until a certain critical value of the latter, beyond which the rate of foam growth exceeds the rate of gas delivery. The level of this exceeding depends on the dynamic surface tension. The lower the value of the dynamic surface tension the larger the level of this exceeding. This rule was found valid until a certain upper limit of the gas delivery rate, at which the dependence on the dynamic surface tension ceases to exist. The second set of experiments was conducted on transient foams. The latter were stabilized by three members of homologue surfactants series: sodium octylsulfate (SOS), sodium decylsulfate (SDeS), and sodium dodecylsulfate (SDS) in the concentration range of 0.01CMC -0.1CMC corresponding to 72.75mN/m to 68.18mN/m. The aqueous solutions of the three surfactant homologues had identical values of static surface tension at the same ratio C/CMC . Bikerman's "unit of foaminess" was measured for each particular case. It was shown that at identical equilibrium surface tensions both the foaminess and the rate of foam decay increase upon lengthening of the surfactant's hydrocarbon chain. It was indicated as well that the foaminess increases linearly upon raising the gas delivery rate until a certain

  14. Design considerations for single-stage and two-stage pneumatic pellet injectors

    SciTech Connect

    Gouge, M.J.; Combs, S.K.; Fisher, P.W.; Milora, S.L.

    1988-09-01

    Performance of single-stage pneumatic pellet injectors is compared with several models for one-dimensional, compressible fluid flow. Agreement is quite good for models that reflect actual breech chamber geometry and incorporate nonideal effects such as gas friction. Several methods of improving the performance of single-stage pneumatic pellet injectors in the near term are outlined. The design and performance of two-stage pneumatic pellet injectors are discussed, and initial data from the two-stage pneumatic pellet injector test facility at Oak Ridge National Laboratory are presented. Finally, a concept for a repeating two-stage pneumatic pellet injector is described. 27 refs., 8 figs., 3 tabs.

  15. Pneumatic Power Drive Wheel and related assembly for Turntable, with ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Pneumatic Power Drive Wheel and related assembly for Turntable, with scale. Not in use August 1994. Turntable rotated with engine and tender on balance by two persons, one on either side at ground level - East Broad Top Railroad & Coal Company, Roundhouse, State Route 994, West of U.S. Route 522, Rockhill Furnace, Huntingdon County, PA

  16. Pneumatic Conveying of Seed Cotton: Minimum Velocity and Pressure Drop

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Electricity is major cost for cotton gins, representing approximately 20% of the industry’s variable costs. Fans used for pneumatic conveying consume the majority of electricity at cotton gins. Development of control systems to reduce the air velocity used for conveying seed cotton could significant...

  17. Pneumatic Conveying of Seed Cotton: Minimum Velocity and Pressure Drop

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Electricity is a major cost for cotton gins, representing approximately 20% of variable costs. Fans used for pneumatic conveying consume the majority of electricity at cotton gins. Development of control systems to reduce the air velocity used for conveying seed cotton could significantly decrease e...

  18. Assessing a pneumatic fractionator as a lint cleaning device

    Technology Transfer Automated Retrieval System (TEKTRAN)

    A study assessed a pneumatic fractionator as a lint cleaning device for ginned lint. Results from a test that used two line pressures and three fractionation times showed that higher line pressure and longer fractionation time produced fiber that was shorter in staple length, contained more neps, a...

  19. 116. PNEUMATIC SUPPLY PANEL IN CENTER OF VEHICLE MECHANICAL SYSTEMS ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    116. PNEUMATIC SUPPLY PANEL IN CENTER OF VEHICLE MECHANICAL SYSTEMS ROOM (111) OF LSB (BLDG. 770), FACING NORTH. CONTROLS FOR FLOW AND PRESSURE REGULATION OF NITROGEN ON RIGHT SIDE OF PANEL; CONTROLS FOR HELIUM ON LEFT SIDE OF PANEL (AT LEFT EDGE OF PHOTO). - Vandenberg Air Force Base, Space Launch Complex 3, Launch Pad 3 West, Napa & Alden Roads, Lompoc, Santa Barbara County, CA

  20. 117. PNEUMATIC SUPPLY PANEL IN CENTER OF VEHICLE MECHANICAL SYSTEMS ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    117. PNEUMATIC SUPPLY PANEL IN CENTER OF VEHICLE MECHANICAL SYSTEMS ROOM (111), LSB (BLDG. 770), FACING NORTH. CONTROLS FOR FLOW AND PRESSURE REGULATION OF HELIUM ON LEFT SIDE OF PANEL; CONTROLS FOR NITROGEN ON RIGHT SIDE OF PANEL (AT RIGHT EDGE OF PHOTO). - Vandenberg Air Force Base, Space Launch Complex 3, Launch Pad 3 West, Napa & Alden Roads, Lompoc, Santa Barbara County, CA

  1. Pneumatic vacuum tube message center, basement room 23, looking southeast ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Pneumatic vacuum tube message center, basement room 23, looking southeast toward doorway and corridor. Note soundproof walls, pedestal flooring, and cable tray suspended from the ceiling - March Air Force Base, Strategic Air Command, Combat Operations Center, 5220 Riverside Drive, Moreno Valley, Riverside County, CA

  2. 14 CFR 23.1438 - Pressurization and pneumatic systems.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 14 Aeronautics and Space 1 2014-01-01 2014-01-01 false Pressurization and pneumatic systems. 23.1438 Section 23.1438 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF... elements must be burst pressure tested to 2.0 times, and proof pressure tested to 1.5 times, the...

  3. 14 CFR 25.1438 - Pressurization and pneumatic systems.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 14 Aeronautics and Space 1 2014-01-01 2014-01-01 false Pressurization and pneumatic systems. 25.1438 Section 25.1438 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF... pressure tested to 2.0 times, and proof pressure tested to 1.5 times, the maximum normal operating...

  4. 60. Shock isolator at center, pneumatic control group panel at ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    60. Shock isolator at center, pneumatic control group panel at left, power distribution box at right, all at right of entrance to lcc. - Ellsworth Air Force Base, Delta Flight, Launch Control Facility, County Road CS23A, North of Exit 127, Interior, Jackson County, SD

  5. Rotary Actuators Based on Pneumatically Driven Elastomeric Structures.

    PubMed

    Gong, Xiangyu; Yang, Ke; Xie, Jingjin; Wang, Yanjun; Kulkarni, Parth; Hobbs, Alexander S; Mazzeo, Aaron D

    2016-09-01

    Unique elastomeric rotary actuators based on pneumatically driven peristaltic motion are demonstrated. Using silicone-based wheels, these motors enable a new class of soft locomotion not found in nature, which is capable of withstanding impact, traversing irregular terrain, and operating in water. For soft robotics, this work marks progress toward providing torque without bending actuators. PMID:27348794

  6. 21 CFR 890.3610 - Rigid pneumatic structure orthosis.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Rigid pneumatic structure orthosis. 890.3610 Section 890.3610 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES PHYSICAL MEDICINE DEVICES Physical Medicine Prosthetic Devices § 890.3610...

  7. 21 CFR 890.3610 - Rigid pneumatic structure orthosis.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Rigid pneumatic structure orthosis. 890.3610 Section 890.3610 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES PHYSICAL MEDICINE DEVICES Physical Medicine Prosthetic Devices § 890.3610...

  8. 21 CFR 890.3610 - Rigid pneumatic structure orthosis.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Rigid pneumatic structure orthosis. 890.3610 Section 890.3610 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES PHYSICAL MEDICINE DEVICES Physical Medicine Prosthetic Devices § 890.3610...

  9. 21 CFR 890.3610 - Rigid pneumatic structure orthosis.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Rigid pneumatic structure orthosis. 890.3610 Section 890.3610 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES PHYSICAL MEDICINE DEVICES Physical Medicine Prosthetic Devices § 890.3610...

  10. Electrostatic Effects in Pneumatic Transport of Granular Materials

    NASA Astrophysics Data System (ADS)

    Lim, Eldin Wee Chuan; Yao, Jun; Zhao, Yanlin

    The methodology of coupling the Discrete Element Method (DEM) with Computational Fluid Dynamics (CFD) was applied for computational studies of pneumatic transport of granular materials through vertical and horizontal pipes in the presence of electrostatic effects. The simulations showed that a thin layer of particles formed and remained adhered to the pipe walls during the pneumatic conveying process due to the effects of strong electrostatic forces of attraction towards the pipe walls. Particle concentrations were generally higher near the pipe walls than at the pipe centre resulting in the ring flow pattern observed in previous experimental studies. The close correspondence between particle velocity vectors and fluid drag force vectors was indicative of the importance of fluid drag forces in influencing particle behaviors. In contrast, the much weaker particle-particle electrostatic repulsion forces had negligible effects on particle behaviors within the system under all operating conditions considered. The electrostatic field strength developed during pneumatic conveying increased with decreasing flow rate due to increased amount of particle-wall collisions. Based on dynamic analyses of forces acting on individual particles, it may be concluded that electrostatic effects played a dominant role in influencing particle behaviors during pneumatic conveying at low flow rates while drag forces became more important at high flow rates.

  11. 21 CFR 890.3610 - Rigid pneumatic structure orthosis.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Rigid pneumatic structure orthosis. 890.3610 Section 890.3610 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES PHYSICAL MEDICINE DEVICES Physical Medicine Prosthetic Devices § 890.3610...

  12. The Pneumatic Common: Learning in, with and from the Air

    ERIC Educational Resources Information Center

    Ford, Derek R.

    2015-01-01

    Air is an immersive substance that envelopes us and binds us together, yet it has dominantly been taken for granted and left out of educational and other theorizations. This article develops a conceptualization of the "pneumatic common" in order to address this gap. The specific intervention staged is within recent educational literature…

  13. Adaptive backstepping slide mode control of pneumatic position servo system

    NASA Astrophysics Data System (ADS)

    Ren, Haipeng; Fan, Juntao

    2016-06-01

    With the price decreasing of the pneumatic proportional valve and the high performance micro controller, the simple structure and high tracking performance pneumatic servo system demonstrates more application potential in many fields. However, most existing control methods with high tracking performance need to know the model information and to use pressure sensor. This limits the application of the pneumatic servo system. An adaptive backstepping slide mode control method is proposed for pneumatic position servo system. The proposed method designs adaptive slide mode controller using backstepping design technique. The controller parameter adaptive law is derived from Lyapunov analysis to guarantee the stability of the system. A theorem is testified to show that the state of closed-loop system is uniformly bounded, and the closed-loop system is stable. The advantages of the proposed method include that system dynamic model parameters are not required for the controller design, uncertain parameters bounds are not need, and the bulk and expensive pressure sensor is not needed as well. Experimental results show that the designed controller can achieve better tracking performance, as compared with some existing methods.

  14. Pneumatic fractures in Confined Granular Media

    NASA Astrophysics Data System (ADS)

    Eriksen, Fredrik K.; Toussaint, Renaud; Jørgen Måløy, Knut; Grude Flekkøy, Eirik; Turkaya, Semih

    2016-04-01

    We will present our ongoing study of the patterns formed when air flows into a dry, non-cohesive porous medium confined in a horizontal Hele-Shaw cell. This is an optically transparent system consisting of two glass plates separated by 0.5 to 1 mm, containing a packing of dry 80 micron beads in between. The cell is rectangular and has an air-permeable boundary (blocking beads) at one short edge, while the other three edges are completely sealed. The granular medium is loosely packed against the semi-permeable boundary and fills about 80 % of the cell volume. This leaves an empty region at the sealed side, where an inlet allows us to set and maintain the air at a constant overpressure (0.1 - 2 bar). For the air trapped inside the cell to relax its overpressure it has to move through the deformable granular medium. Depending on the applied overpressure and initial density of the medium, we observe a range of different behaviors such as seepage through the pore-network with or without an initial compaction of the solid, formation of low density bubbles with rearrangement of particles, granular fingering/fracturing, and erosion inside formed channels/fractures. The experiments are recorded with a high-speed camera at a framerate of 1000 images/s and a resolution of 1024x1024 pixels. We use various image processing techniques to characterize the evolution of the air invasion patterns and the deformations in the surrounding material. The experiments are similar to deformation processes in porous media which are driven by pore fluid overpressure, such as mud volcanoes and hydraulic or pneumatic (gas-induced) fracturing, and the motivation is to increase the understanding of such processes by optical observations. In addition, this setup is an experimental version of the numerical models analyzed by Niebling et al. [1,2], and is useful for comparison with their results. In a directly related project [3], acoustic emissions from the cell plate are recorded during

  15. The Cutaneous Rabbit Revisited

    ERIC Educational Resources Information Center

    Flach, Rudiger; Haggard, Patrick

    2006-01-01

    In the cutaneous rabbit effect (CRE), a tactile event (so-called attractee tap) is mislocalized toward an adjacent attractor tap. The effect depends on the time interval between the taps. The authors delivered sequences of taps to the forearm and asked participants to report the location of one of the taps. The authors replicated the original CRE…

  16. Evaluation of the pneumatic tube system for transportation of packed red cell units

    PubMed Central

    Dhar, Supriya; Basu, Sabita; Chakraborty, Subhosmito; Sinha, Subir

    2015-01-01

    Background: Pneumatic tube system (PTS) is commonly used in hospital settings to transport blood samples to diagnostic laboratories. At our blood center, we receive blood requisitions via the PTS, but units are carried to the ward by human courier. Recently we considered using the PTS for transporting blood units. Since, there are reports of hemolysis in blood samples sent through the PTS, we evaluated this system for transporting red cell units. Aims: The aim was to assess the effect of PTS transport on the quality of packed red cell units. Materials and Methods: A total of 50 red blood cells units (RBC), (25 non-irradiated and 25 irradiated) were subjected to transportation through the PTS. The control arm in the study was age-matched RBC units not subjected to PTS transport. Each RBC unit was evaluated for hemoglobin (Hb), lactate dehydrogenase, potassium and plasma hemoglobin (Hb). The paired t-test was used to compare these parameters, and the P value was calculated. Results and Conclusion: The percentage of hemolysis after transportation through PTS was below the recommended guidelines. Delivery of the blood unit to the wrong station, bags lying unattended at the destination were few of the problems that had to be addressed. To conclude, though the PTS is a safe means of transporting blood products with reduction in the turn-around-time, it must be validated before use. PMID:26420944

  17. Development of pneumatic thrust-deflecting powered-lift systems

    NASA Technical Reports Server (NTRS)

    Englar, R. J.; Nichols, J. H., Jr.; Harris, M. J.; Eppel, J. C.; Shovlin, M. D.

    1986-01-01

    Improvements introduced into the Circulation Control Wing/Upper Surface Blowing (CCW/USB) STOL concept (Harris et al., 1982) are described along with results of the full-scale static ground tests and model-scale wind tunnel investigations. Tests performed on the full-scale pneumatic thrust-deflecting system installed on the NASA QSRA aircraft have demonstrated that, relative to the original baseline configuration, a doubling of incremental thrust deflection due to blowing resulted from improvements that increased the blowing span and momentum, as well as from variations in blowing slot height and geometry of the trailing edge. A CCW/Over the Wing model has been built and tested, which was shown to be equivalent to the CCW/USB system in terms of pneumatic thrust deflection and lift generation, while resolving the problem of cruise thrust loss due to exhaust scrubbing on the wing upper surface.

  18. Liquid-metal dip seal with pneumatic spring

    DOEpatents

    Poindexter, Allan M.

    1977-01-01

    An improved liquid-metal dip seal for sealing the annulus between rotating plugs in the reactor vessel head of a liquid-metal fast-breeder nuclear reactor has two legs of differing widths communicating under a seal blade; the wide leg is also in communication with cover gas of the reactor and the narrow leg is also in communication with an isolated plug annulus above the seal. The annulus contains inert gas which acts as a pneumatic spring. Upon increasing cover gas pressure which depresses the level in the wide leg and greatly increases the level in the narrow leg, the pneumatic spring is compressed, and resists further level changes, thus preventing radioactive cover gas from bubbling through the seal.

  19. Performance characterization of pneumatic single pellet injection system

    SciTech Connect

    Schuresko, D.D.; Milora, S.L.; Hogan, J.T.; Foster, C.A.; Combs, S.K.

    1982-01-01

    The Oak Ridge National Laboratory single-shot pellet injector, which has been used in plasma fueling experiments on ISX and PDX, has been upgraded and extensively instrumented in order to study the gas dynamics of pneumatic pellet injection. An improved pellet transport line was developed which utilizes a 0.3-cm-diam by 100-cm-long guide tube. Pellet gun performance was characterized by measurements of breech and muzzle dynamic pressures and by pellet velocity and mass determinations. Velocities up to 1.4 km/s were achieved for intact hydrogen pellets using hydrogen propellant at 5-MPa breech pressure. These data have been compared with new pellet acceleration calculations which include the effects of propellant friction, heat transfer, time-dependent boundary conditions, and finite gun geometry. These results provide a basis for the extrapolation of present-day pneumatic injection system performance to velocities in excess of 2 km/s.

  20. Pneumatic Regolith Transfer Systems for In-Situ Resource Utilization

    NASA Technical Reports Server (NTRS)

    Mueller, Robert P.; Townsend, Ivan I., III; Mantovani, James G.

    2010-01-01

    One aspect of In-Situ Resource Utilization (lSRU) in a lunar environment is to extract oxygen and other elements from the minerals that make up the lunar regolith. Typical ISRU oxygen production processes include but are not limited to hydrogen reduction, carbothermal and molten oxide electrolysis. All of these processes require the transfer of regolith from a supply hopper into a reactor for chemical reaction processing, and the subsequent extraction of the reacted regolith from the reactor. This paper will discuss recent activities in the NASA ISRU project involved with developing pneumatic conveying methods to achieve lunar regolith simulant transfer under I-g and 1/6-g gravitational environments. Examples will be given of hardware that has been developed and tested by NASA on reduced gravity flights. Lessons learned and details of pneumatic regolith transfer systems will be examined as well as the relative performance in a 1/6th G environment

  1. Modeling and control of a pneumatically actuated inverted pendulum.

    PubMed

    Zilić, Tihomir; Pavković, Danijel; Zorc, Davor

    2009-07-01

    This paper presents the results of modeling of an inverted pendulum system driven by a linear pneumatic motor and equipped with relatively low-cost potentiometer-based position measurement system. Based on the nonlinear model of the overall pendulum system, which also includes notable friction effects, a linearized model is derived. The linearized model is used as a basis for the design of state feedback controller based on LQ and LQG optimization procedures. The linear state feedback controllers are augmented by a compensator of nonlinear friction effects whose design is based on the results of experimental identification of an appropriate static friction model. The proposed pendulum controller structures have been verified by means of computer simulations and experimentally on the experimental setup of a pneumatically actuated inverted pendulum.

  2. Pneumatic permeability measurements in a fractured, partially saturated environment

    SciTech Connect

    Guzman, A.; Sully, M.; Neuman, S.; Lohrstorfer, C.

    1993-06-01

    In the context of underground disposal of high-level radioactive wastes, the hydraulic conductivity of the host environment is an extremely important parameter. The research task of the authors addresses the technical design of instrumentation and the theoretical aspects of air flow through fractured, unsaturated rocks. Determinations of the pneumatic permeability are being conducted at different scales in selected boreholes located in unsaturated tuff at the Apache Leap Tuff site. 1 fig.

  3. A pneumatic sample changer for gamma-ray spectroscopy

    USGS Publications Warehouse

    Massoni, C.J.; Fones, R.V.; Simon, F.O.

    1973-01-01

    A gravity-feed, pneumatic-ejection sample changer has been developed. The changer is suitable for both flat and well-type detectors and permits the continuous use of gamma-ray spectroscopy equipment 24 h a day, 7 days a week. The electronic circuitry has a fail-safe feature which stops the operation of the changer if a malfunction occurs. ?? 1973 The American Institute of Physics.

  4. Pneumatic Muscle Actuated Equipment for Continuous Passive Motion

    NASA Astrophysics Data System (ADS)

    Deaconescu, Tudor T.; Deaconescu, Andrea I.

    2009-10-01

    Applying continuous passive rehabilitation movements as part of the recovery programme of patients with post-traumatic disabilities of the bearing joints of the inferior limbs requires the development of new high performance equipment. This chapter discusses a study of the kinematics and performance of such a new, continuous passive motion based rehabilitation system actuated by pneumatic muscles. The utilized energy source is compressed air ensuring complete absorption of the end of stroke shocks, thus minimizing user discomfort.

  5. Numerical study of vertical pneumatic conveying: Effect of friction coefficient

    NASA Astrophysics Data System (ADS)

    Li, K.; Kuang, S. B.; Zou, R. P.; Pan, R. H.; Yu, A. B.

    2013-06-01

    This paper presents a numerical study of vertical pneumatic conveying by a combined approach of computational fluid dynamics for gas phase and discrete element method for solid phase. The effects of friction coefficient on the flows in regard with particle flow patterns and their transition, reverse flow, and gas pressure behavior are qualified. The forces acting on particles are analyzed in detail to understand the underlying mechanisms.

  6. Dynamic Analysis of Sounding Rocket Pneumatic System Revision

    NASA Technical Reports Server (NTRS)

    Armen, Jerald

    2010-01-01

    The recent fusion of decades of advancements in mathematical models, numerical algorithms and curve fitting techniques marked the beginning of a new era in the science of simulation. It is becoming indispensable to the study of rockets and aerospace analysis. In pneumatic system, which is the main focus of this paper, particular emphasis will be placed on the efforts of compressible flow in Attitude Control System of sounding rocket.

  7. Detection of the breakage of pharmaceutical tablets in pneumatic transport.

    PubMed

    Albion, Katherine; Briens, Lauren; Briens, Cedric; Berruti, Franco

    2006-09-28

    Pneumatic transport of pharmaceutical tablets is very convenient, compact and greatly reduces contamination. A potential problem, however, is the breakage of a significant fraction of the transported tablets, causing serious product quality problems. Since the flowrate of tablets transported through a given pneumatic transport line increases with gas velocity, lines are often operated at gas velocities slightly below the velocity at which tablets break. Minor changes in operating conditions can have a large effect on the impact resistance of tablets and on the observed tablet breakage rate. Therefore, maintaining a constant gas velocity is not sufficient to keep the tablet breakage rate below an acceptable level. The objective of the present study was to develop a reliable and non-invasive on-line method for the detection of tablet breakage. Pharmaceutical acetaminophen tablets were transported pneumatically in a 0.1 m diameter pipeline consisting of a 5 m vertical and a 4.0 m horizontal section made of either re-enforced PVC or steel. The pipeline flow regime was determined by visual observation through clear pipeline sections. Tablet breakage was quantified by screening tablet samples. Acoustic measurements were recorded at different locations along the pipeline. Analysis of the signals from microphones attached to the wall of the elbow and horizontal section provided a reliable detection of conditions leading to tablet breakage.

  8. Design and Control of a Pneumatically Actuated Transtibial Prosthesis

    PubMed Central

    Zheng, Hao; Shen, Xiangrong

    2015-01-01

    This paper presents the design and control of a pneumatically actuated transtibial prosthesis, which utilizes a pneumatic cylinder-type actuator to power the prosthetic ankle joint to support the user's locomotion. The pneumatic actuator has multiple advantages over the traditional electric motor, such as light weight, low cost, and high power-to-weight ratio. The objective of this work is to develop a compact and lightweight transtibial prosthesis, leveraging the multiple advantages provided by this highly competitive actuator. In this paper, the design details of the prosthesis are described, including the determination of performance specifications, the layout of the actuation mechanism, and the calculation of the torque capacity. Through the authors’ design calculation, the prosthesis is able to provide sufficient range of motion and torque capacity to support the locomotion of a 75 kg individual. The controller design is also described, including the underlying biomechanical analysis and the formulation of the finite-state impedance controller. Finally, the human subject testing results are presented, with the data indicating that the prosthesis is able to generate a natural walking gait and sufficient power output for its amputee user. PMID:26146497

  9. Evaluation of unsaturated zone air permeability through pneumatic tests

    USGS Publications Warehouse

    Baehr, Arthur L.; Hult, Marc F.

    1991-01-01

    Predicting the steady state distribution of air pressure in the unsaturated zone resulting from a pneumatic test provides a method for determining air-phase permeability. This technique is analogous to the inverse problem of well hydraulics; however, air flow is more complicated than ground water flow because of air compressibility, the Klinkenberg effect, variations in air density and viscosity that result from temperature fluctuations in the unsaturated zone and the possibility of inducing water movement during the pneumatic test. An analysis of these complicating factors reveals that, when induced water movement can be neglected, a linear version of the airflow equation can provide an appropriate approximation for the purpose of determining air-phase permeability. Two analytical solutions for steady state, two-dimensional, axisymmetric airflow to a single well partially screened in the unsaturated zone are developed. One solution applies where there is a stratum of relatively low air permeability, separating the stratum in which the well is completed, from the atmosphere. The other solution applies where there is no separating stratum between the domain and atmosphere. In both situations the water table forms the lower horizontal boundary. Applications of both solutions to determine air permeability from data collected during pneumatic tests are presented.

  10. A Model-Based Prognostics Approach Applied to Pneumatic Valves

    NASA Technical Reports Server (NTRS)

    Daigle, Matthew J.; Goebel, Kai

    2011-01-01

    Within the area of systems health management, the task of prognostics centers on predicting when components will fail. Model-based prognostics exploits domain knowledge of the system, its components, and how they fail by casting the underlying physical phenomena in a physics-based model that is derived from first principles. Uncertainty cannot be avoided in prediction, therefore, algorithms are employed that help in managing these uncertainties. The particle filtering algorithm has become a popular choice for model-based prognostics due to its wide applicability, ease of implementation, and support for uncertainty management. We develop a general model-based prognostics methodology within a robust probabilistic framework using particle filters. As a case study, we consider a pneumatic valve from the Space Shuttle cryogenic refueling system. We develop a detailed physics-based model of the pneumatic valve, and perform comprehensive simulation experiments to illustrate our prognostics approach and evaluate its effectiveness and robustness. The approach is demonstrated using historical pneumatic valve data from the refueling system.

  11. Vibration and recoil control of pneumatic hammers. [by air flow pressure regulation

    NASA Technical Reports Server (NTRS)

    Constantinescu, I. N.; Darabont, A. V.

    1974-01-01

    Vibration sources are described for pneumatic hammers used in the mining industry (pick hammers), in boiler shops (riveting hammers), etc., bringing to light the fact that the principal vibration source is the variation in air pressure inside the cylinder. The present state of the art of vibration control of pneumatic hammers as it is practiced abroad, and the solutions adopted for this purpose, are discussed. A new type of pneumatic hammer with a low noise and vibration level is presented.

  12. Formulation of a minimum variance deconvolution technique for compensation of pneumatic distortion in pressure sensing devices

    NASA Technical Reports Server (NTRS)

    Whitmore, Stephen A.

    1990-01-01

    Increasingly, aircraft system designs require that aerodynamic parameters derived from pneumatic measurements be employed as control-system feedbacks. Such high frequency pressure measurements' accuracy is compromised by pressure distortion due to frictional attenuation and pneumatic resonance within the sensing system. A pneumatic distortion model is here formulated and reduced to a low-order state-variable model which retains most of the full model's dynamic characteristics. This reduced-order model is coupled with standard results from minimum variance estimation theory to develop an algorithm to compensate for pneumatic-distortion effects.

  13. Clinical Effect of Endoscopic Pneumatic Dilation for Achalasia

    PubMed Central

    Cheng, Peng; Shi, Hai; Zhang, Yanjie; Zhou, Huabang; Dong, Jinhua; Cai, Yiting; Hu, Xing; Dai, Qiang; Yang, Wenyan

    2015-01-01

    Abstract Although pneumatic dilation is an accepted method for the treatment of achalasia, this therapy has high recurrence and complication rates, and prolonged follow-up studies on the parameters associated with various outcomes are rare. In this prospective 10-year follow-up study, a satisfactory therapeutic effect was achieved without serious complications. We report the therapeutic experience with pneumatic dilation, having aimed to evaluate the long-term clinical safety and efficacy of pneumatic dilation. In total, 35 consecutive patients with idiopathic achalasia who underwent pneumatic dilation were followed up at regular intervals in person or by a phone interview over a 10-year period. The mean duration of the follow-up was 43.03 ± 26.34 months (range 6–120 months). Remission was assessed by the dysphagia classification and symptom scores. Patients’ clinical symptom scores were calculated before and at 6 to 36 months, 37 to 60 months, and >60 months after therapy. The influence of the patients’ age, gender, and disease duration on the therapeutic effect was analyzed. The success rate of the operation was 97.2% (35/36), without massive hemorrhaging, perforation or other serious complications. Dysphagia after the therapy was significantly eased (P < 0.01). In total, 35 patients have been followed up for 6 to 36 months after therapy, 21 cases for 37 to 60 months, and 5 cases for >60 months, and the patients’ symptom scores separately decreased significantly compared with the pretherapy scores (P < 0.01). For these patients, the 6 to 36 months remission rate was 85.7% (30/35), the 37 to 60 months rate was 61.9% (13/21), and the >60 months rate was 40% (2/5). The dilation effect had no relationship to the patient's age, gender, and disease duration (P > 0.05). The patients in 30 cases (85.7%) were successfully treated with a single dilation, in 4 cases (11.4%) with 2 dilations, and in 1 case (2.9%) with 3 dilations

  14. Irradiation effect of polarization direction and intensity of semiconductor laser on injured peripheral nerve

    NASA Astrophysics Data System (ADS)

    Guo-Xin, Xiong; Lei-lei, Xiong

    2016-08-01

    To investigate the irradiation effect of polarization direction and the intensity of a semiconductor laser on the injured peripheral nerve in rabbits, the model of the injured common peroneal nerve was established, the L5,6 spinal segments of the rabbits were irradiated, a uniform rotating polarizer was placed at the laser output which made the polarization direction and intensity of the output laser change according to the 80 Hz cosine law. The experimental results show that irradiating the spinal segment of injured nerves in rabbits with this changeable semiconductor laser can significantly promote the regeneration of injured peripheral nerves and the function recovery.

  15. Pulmonary pneumaticity in the postcranial skeleton of extant aves: a case study examining Anseriformes.

    PubMed

    O'Connor, Patrick M

    2004-08-01

    Anseriform birds were surveyed to examine how the degree of postcranial pneumaticity varies in a behaviorally and size-diverse clade of living birds. This study attempts to extricate the relative effects of phylogeny, body size, and behavioral specializations (e.g., diving, soaring) that have been postulated to influence the extent of postcranial skeletal pneumaticity. One hundred anseriform species were examined as the focal study group. Methods included latex injection of the pulmonary apparatus followed by gross dissection or direct examination of osteological specimens. The Pneumaticity Index (PI) is introduced as a means of quantifying and comparing postcranial pneumaticity in a number of species simultaneously. Phylogenetically independent contrasts (PICs) were used to examine the relationship between body size and the degree of postcranial pneumaticity throughout the clade. There is a high degree of similarity (i.e., clade-specificity) within most anseriform subgroups. As a whole, Anseriformes demonstrate no significant relationship between relative pneumaticity and body size, as indicated by regression analysis of body mass on PI. It is apparent, however, that many clades of diving ducks do exhibit lower PIs than their nondiving relatives. By exclusion of diving taxa from analyses, a significant positive slope is observed and the hypothesis of relatively higher pneumaticity in larger-bodied birds is only weakly supported. However, low correlations indicate that factors other than body size account for much of the variation observed in relative pneumaticity. Pneumaticity profiles were mapped onto existing phylogenetic hypotheses. A reduction in the degree of postcranial pneumaticity occurred independently in at least three anseriform subclades specialized for diving. Finally, enigmatic pneumatic features located in distal forelimb elements of screamers (Anhimidae) result from invasion of bone by a network of subcutaneous air sac diverticula spreading

  16. Gait Using Pneumatic Brace for End-Stage Knee Osteoarthritis.

    PubMed

    Kapadia, Bhaveen H; Cherian, Jeffrey Jai; Starr, Roland; Chughtai, Morad; Mont, Michael A; Harwin, Steven F; Bhave, Anil

    2016-04-01

    More than 20 million individuals in the United States are affected by knee osteoarthritis (OA), which can lead to altered biomechanics and excessive joint loading. The use of an unloader pneumatic brace with extension assist has been proposed as a nonoperative treatment modality that may improve gait mechanics and correct knee malalignment. We assessed the following parameters in patients who have knee OA treated with and without a brace: (1) changes in temporospatial parameters in gait; (2) knee range of motion, knee extension at heel strike, and foot placement; (3) knee joint moments and impulse; and (4) changes in dynamic stiffness and rate of change of knee flexion during midstance to terminal stance. This 2:1 prospective, randomized, single-blinded trial evaluated 36 patients (24 brace and 12 matching). OA knee patients were randomized to receive either a pneumatic unloader brace or a standard nonoperative treatment regimen as the matching cohort for a 3-month period. They underwent evaluation of gait parameters using a three-dimensional gait analysis system at their initial appointment and at 3 months follow-up. All the testing, pre- and postbracing were performed without wearing the brace to examine for retained effects. Treatment with the brace led to significant improvements versus standard treatment in various gait parameters. Patients in the brace group had improvements in walking speed, knee extension at heel strike, total range of motion, knee joint forces, and rate of knee flexion from midstance to terminal stance when compared with the matching cohort. Knee OA patients who used a pneumatic unloader brace for 3 months for at least 3 hours per day had significant improvements various gait parameters when compared with a standard nonoperative therapy cohort. Braced patients demonstrated gait-modifying affects when not wearing the brace. These results are encouraging and suggest that this device represents a promising treatment modality for knee OA that

  17. 49 CFR 571.129 - Standard No. 129; New non-pneumatic tires for passenger cars.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    .../Wheel Center Member Matching Information. For purposes of this standard, S8 of 49 CFR 571.110 and S10 of 49 CFR 571.120, each manufacturer of a non-pneumatic tire that is not an integral part of a non...-pneumatic test rim or test wheel center member, the test shall be suspended and no further testing...

  18. 49 CFR 571.129 - Standard No. 129; New non-pneumatic tires for passenger cars.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    .../Wheel Center Member Matching Information. For purposes of this standard, S8 of 49 CFR 571.110 and S10 of 49 CFR 571.120, each manufacturer of a non-pneumatic tire that is not an integral part of a non...-pneumatic test rim or test wheel center member, the test shall be suspended and no further testing...

  19. 49 CFR 571.129 - Standard No. 129; New non-pneumatic tires for passenger cars.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    .../Wheel Center Member Matching Information. For purposes of this standard, S8 of 49 CFR 571.110 and S10 of 49 CFR 571.120, each manufacturer of a non-pneumatic tire that is not an integral part of a non...-pneumatic test rim or test wheel center member, the test shall be suspended and no further testing...

  20. 49 CFR 571.129 - Standard No. 129; New non-pneumatic tires for passenger cars.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    .../Wheel Center Member Matching Information. For purposes of this standard, S8 of 49 CFR 571.110 and S10 of 49 CFR 571.120, each manufacturer of a non-pneumatic tire that is not an integral part of a non...-pneumatic test rim or test wheel center member, the test shall be suspended and no further testing...

  1. 46 CFR 54.10-15 - Pneumatic test (modifies UG-100).

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... testing of welded pressure vessels shall be permitted only for those units which are so designed and/or...) Except for enameled vessels, for which the pneumatic test pressure shall be at least equal to, but need not exceed, the maximum allowable working pressure to be marked on the vessel, the pneumatic...

  2. 21 CFR 874.4250 - Ear, nose, and throat electric or pneumatic surgical drill.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Ear, nose, and throat electric or pneumatic... AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES EAR, NOSE, AND THROAT DEVICES Surgical Devices § 874.4250 Ear, nose, and throat electric or pneumatic surgical drill. (a) Identification. An ear, nose,...

  3. 21 CFR 874.4250 - Ear, nose, and throat electric or pneumatic surgical drill.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Ear, nose, and throat electric or pneumatic... AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES EAR, NOSE, AND THROAT DEVICES Surgical Devices § 874.4250 Ear, nose, and throat electric or pneumatic surgical drill. (a) Identification. An ear, nose,...

  4. 21 CFR 874.4250 - Ear, nose, and throat electric or pneumatic surgical drill.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Ear, nose, and throat electric or pneumatic... AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES EAR, NOSE, AND THROAT DEVICES Surgical Devices § 874.4250 Ear, nose, and throat electric or pneumatic surgical drill. (a) Identification. An ear, nose,...

  5. 46 CFR 128.240 - Hydraulic or pneumatic power and control-materials and pressure design.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... Hydraulic or pneumatic power and control—materials and pressure design. (a) Each standard piping component... 46 Shipping 4 2012-10-01 2012-10-01 false Hydraulic or pneumatic power and control-materials and pressure design. 128.240 Section 128.240 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY...

  6. 46 CFR 128.240 - Hydraulic or pneumatic power and control-materials and pressure design.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... Hydraulic or pneumatic power and control—materials and pressure design. (a) Each standard piping component... 46 Shipping 4 2013-10-01 2013-10-01 false Hydraulic or pneumatic power and control-materials and pressure design. 128.240 Section 128.240 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY...

  7. 46 CFR 128.240 - Hydraulic or pneumatic power and control-materials and pressure design.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... Hydraulic or pneumatic power and control—materials and pressure design. (a) Each standard piping component... 46 Shipping 4 2014-10-01 2014-10-01 false Hydraulic or pneumatic power and control-materials and pressure design. 128.240 Section 128.240 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY...

  8. His majesty's subjects: from laboratory to human experiment in pneumatic chemistry.

    PubMed

    Stewart, Larry

    2009-09-20

    Experiments in pneumatic chemistry paved the way for medical innovation in the last quarter of the eighteenth century. Thomas Beddoes and James Watt were instrumental in the spread of the use of new gas chemistry in pneumatic therapy, but they were far from alone. There was no shortage of experimental subjects, as the practice was quickly taken up by medics throughout Britain.

  9. 49 CFR 571.117 - Standard No. 117; Retreaded pneumatic tires.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... Federal Motor Vehicle Safety Standards § 571.117 Standard No. 117; Retreaded pneumatic tires. S1. Scope... car tires to meet safety criteria similar to those for new pneumatic passenger car tires. S3... 1948. S4. Definitions. S4.1Casing means a used tire to which additional tread may be attached for...

  10. 40 CFR 60.253 - Standards for pneumatic coal-cleaning equipment.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 7 2012-07-01 2012-07-01 false Standards for pneumatic coal-cleaning... PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Coal Preparation and Processing Plants § 60.253 Standards for pneumatic coal-cleaning equipment. (a) On and...

  11. 40 CFR 60.253 - Standards for pneumatic coal-cleaning equipment.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 7 2014-07-01 2014-07-01 false Standards for pneumatic coal-cleaning... PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Coal Preparation and Processing Plants § 60.253 Standards for pneumatic coal-cleaning equipment. (a) On and...

  12. 40 CFR 60.253 - Standards for pneumatic coal-cleaning equipment.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 6 2010-07-01 2010-07-01 false Standards for pneumatic coal-cleaning... PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Coal Preparation and Processing Plants § 60.253 Standards for pneumatic coal-cleaning equipment. (a) On and...

  13. 40 CFR 60.253 - Standards for pneumatic coal-cleaning equipment.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 7 2013-07-01 2013-07-01 false Standards for pneumatic coal-cleaning... PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Coal Preparation and Processing Plants § 60.253 Standards for pneumatic coal-cleaning equipment. (a) On and...

  14. 40 CFR 60.253 - Standards for pneumatic coal-cleaning equipment.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 6 2011-07-01 2011-07-01 false Standards for pneumatic coal-cleaning... PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Coal Preparation and Processing Plants § 60.253 Standards for pneumatic coal-cleaning equipment. (a) On and...

  15. 49 CFR 571.129 - Standard No. 129; New non-pneumatic tires for passenger cars.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ...-pneumatic rim or wheel center member shall satisfy the dimensional specifications contained in the.../Wheel Center Member Matching Information. For purposes of this standard, S8 of 49 CFR 571.110 and S10 of 49 CFR 571.120, each manufacturer of a non-pneumatic tire that is not an integral part of a...

  16. Compact, Non-Pneumatic Rock-Powder Samplers

    NASA Technical Reports Server (NTRS)

    Sherrit, Stewart; Bar-Cohen, Yoseph; Badescu, Mircea; Bao, Xiaoqi; Chang, Zensheu; Jones, Christopher; Aldrich, Jack

    2008-01-01

    Tool bits that automatically collect powdered rock, permafrost, or other hard material generated in repeated hammering action have been invented. The present invention pertains to the special case in which it is desired to collect samples in powder form for analysis by x-ray diffraction and possibly other techniques. The present invention eliminates the need for both the mechanical collection equipment and the crushing chamber and the pneumatic collection equipment of prior approaches, so that it becomes possible to make the overall sample-acquisition apparatus more compact.

  17. PNEUMATIC MICROVALVE FOR ELECTROKINETIC SAMPLE PRECONCENTRATION AND CAPILLARY ELECTROPHORESIS INJECTION

    SciTech Connect

    Cong, Yongzheng; Rausch, Sarah J.; Geng, Tao; Jambovane, Sachin R.; Kelly, Ryan T.

    2014-10-27

    Here we show that a closed pneumatic microvalve on a PDMS chip can serve as a semipermeable membrane under an applied potential, enabling current to pass through while blocking the passage of charged analytes. Enrichment of both anionic and cationic species has been demonstrated, and concentration factors of ~70 have been achieved in just 8 s. Once analytes are concentrated, the valve is briefly opened and the sample is hydrodynamically injected onto an integrated microchip or capillary electrophoresis (CE) column. In contrast to existing preconcentration approaches, the membrane-based method described here enables both rapid analyte concentration as well as high resolution separations.

  18. An investigation of swirl flow field in pneumatic conveying duct

    NASA Astrophysics Data System (ADS)

    Huang, Xijun; Dong, Jinzhong

    1992-10-01

    The swirl flow field of a pneumatic conveying system is investigated experimentally. The swirl is imparted to the flow by the use of swirl vanes. A five-hole probe is used for measuring the tangential angle of flow, axial velocity, static pressure of flow, and swirl number in the flow sections of a conveying system. It is shown that the existence of a central screw conveyer produces the contrary swirl flow under some of the swirl vane angle conditions. The larger axial velocity is produced in the outer annular layer of flow. The maximum value of the swirl number in the flow sections agrees with a simplified theoretical relation.

  19. [Use of pneumatic braces in the rehabilitation of motor handicaps].

    PubMed

    Rideau, Y; Brault, J F; Caillaud, J

    1975-01-01

    The authors describe the advantages of pneumatic orthesis which are: On a mechanical standpoint the comfort related to the lightness and elasticity of the bracing allowing better walking, specialty in paraplegies from thoracic level. The rigidity of the orthesis can be changed by modifying the air-pressure and this type of bracing can be used in various diseases such as cerebral palsy or myopathies. On a social standpoint this type of orthesis can be obtained more rapidly than conventional ones. It allows a shorter hospitalization and, therefore, a better rehabilitation.

  20. 78 FR 77101 - Certain New Pneumatic Off-the-Road Tires From the People's Republic of China: Final Results of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-12-20

    ... International Trade Administration Certain New Pneumatic Off-the-Road Tires From the People's Republic of China...'') initiated a sunset review of the countervailing duty order on certain new pneumatic off-the-road tires (OTR... of China (GOC) and respondent interested parties. \\1\\ See Certain New Pneumatic Off-the-Road...

  1. 75 FR 46914 - Certain New Pneumatic Off-the-Road Tires From the People's Republic of China: Final Results of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-08-04

    ... International Trade Administration Certain New Pneumatic Off-the-Road Tires From the People's Republic of China... certain new pneumatic off-the-road tires (``OTR tires'') from the People's Republic of China (``PRC'').\\1... Jinyu. \\1\\ See Certain New Pneumatic Off-the-Road Tires from the People's Republic of China:...

  2. 75 FR 49459 - Certain New Pneumatic Off-The-Road Tires from the People's Republic of China: Notice of Amended...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-08-13

    ..., 73 FR 40485 (July 15, 2008) (``Final Determination''); Certain New Pneumatic Off-the-Road Tires from... International Trade Administration A-570-912 Certain New Pneumatic Off-The-Road Tires from the People's Republic... determination in the antidumping investigation on certain new pneumatic off-the-road tires (``OTR tires'')...

  3. 77 FR 26508 - Certain New Pneumatic Off-the-Road Tires From the People's Republic of China: Initiation of New...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-05-04

    ... International Trade Administration Certain New Pneumatic Off-the-Road Tires From the People's Republic of China... shipper review.\\5\\ \\1\\ See Certain New Pneumatic Off-the-Road Tires From the People's Republic of China... Request of Trelleborg Wheel Systems (Xingtai) China, Co. Ltd.: New Pneumatic Off-The-Road Tires from...

  4. 78 FR 70917 - Certain New Pneumatic Off-the-Road Tires From the People's Republic of China: Notice of Decision...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-11-27

    ... International Trade Administration Certain New Pneumatic Off-the-Road Tires From the People's Republic of China... (Department) relating to the countervailing duty (CVD) investigation on certain new pneumatic off- the-road... in Certain New Pneumatic Off-the-Road Tires From the People's Republic of China: Notice of...

  5. 75 FR 31422 - Certain New Pneumatic Off-The-Road Tires from the People's Republic of China: Notice of Decision...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-06-03

    ... International Trade Administration A-570-912 Certain New Pneumatic Off-The-Road Tires from the People's Republic... antidumping investigation on certain new pneumatic off-the-road tires (``OTR tires'') from the People's... Pneumatic Off-The-Road-Tires from the People's Republic of China: Final Affirmative Determination of...

  6. 75 FR 64268 - New Pneumatic Off-the-Road Tires From the People's Republic of China: Preliminary Results of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-10-19

    ... International Trade Administration New Pneumatic Off-the-Road Tires From the People's Republic of China... duty order on certain new pneumatic off-the- road tires (OTR Tires) from the People's Republic of China... (CVD) order on OTR tires from the People's Republic of China. See Certain New Pneumatic...

  7. 75 FR 62504 - Certain New Pneumatic Off-the-Road Tires From the People's Republic of China: Notice of Decision...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-10-12

    ... International Trade Administration Certain New Pneumatic Off-the-Road Tires From the People's Republic of China... investigation on certain new pneumatic off-the-road tires (``OTR tires'') from the People's Republic of China...''). See Certain New Pneumatic Off-The-Road-Tires from the People's Republic of China: Final...

  8. 75 FR 76956 - Certain New Pneumatic Off-the-Road Tires From the People's Republic of China: Rescission, in Part...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-12-10

    ... International Trade Administration Certain New Pneumatic Off-the-Road Tires From the People's Republic of China... pneumatic off-the-road tires (OTR Tires) from the People's Republic of China (PRC) for the period January 1... Certain New Pneumatic Off-the-Road Tires From the People's Republic of China: Partial Rescission...

  9. 76 FR 23286 - New Pneumatic Off-the-Road Tires From the People's Republic of China: Final Results of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-04-26

    ... International Trade Administration New Pneumatic Off-the-Road Tires From the People's Republic of China: Final... certain new pneumatic off-the- road tires (OTR Tires) from the People's Republic of China (PRC) for the.... See New Pneumatic Off-the-Road Tires From the People's Republic of China: Preliminary Results...

  10. 76 FR 4298 - Certain New Pneumatic Off-the-Road Tires From the People's Republic of China: Notice of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-01-25

    ... International Trade Administration Certain New Pneumatic Off-the-Road Tires From the People's Republic of China... changed circumstances review (``CCR'') of the antidumping duty order on certain new pneumatic off-the-road... rescinding this CCR. \\1\\ See Certain New Pneumatic Off-the-Road Tires from the People's Republic of...

  11. 77 FR 4996 - Certain New Pneumatic Off-the-Road Tires From the People's Republic of China: Rescission of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-02-01

    ... International Trade Administration Certain New Pneumatic Off-the-Road Tires From the People's Republic of China... administrative review of the countervailing duty order on certain new pneumatic off-the-road tires (OTR Tires... Pneumatic Off-the-road Tires from the People's Republic of China: Respondent Selection,'' dated December...

  12. 76 FR 31584 - Certain New Pneumatic Off-the-Road Tires From the People's Republic of China: Extension of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-06-01

    ... International Trade Administration Certain New Pneumatic Off-the-Road Tires From the People's Republic of China... new pneumatic off-the-road tires from the People's Republic of China (``PRC''). This review covers the... administrative review of the antidumping duty order on certain new pneumatic off-the-road tires from the PRC....

  13. 77 FR 14495 - Certain New Pneumatic Off-the-Road Tires From the People's Republic of China: Final Results of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-03-12

    ... International Trade Administration Certain New Pneumatic Off-the-Road Tires From the People's Republic of China...-2010 administrative review of the antidumping duty order on certain new pneumatic off-the-road tires... International Co., Ltd. (``TUTRIC''). \\1\\ See Certain New Pneumatic Off-the-Road Tires From the...

  14. 78 FR 22513 - Certain New Pneumatic Off-the-Road Tires From the People's Republic of China: Final Results of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-04-16

    ... International Trade Administration Certain New Pneumatic Off-the-Road Tires From the People's Republic of China... administrative review of the antidumping duty order on certain new pneumatic off-the-road tires (``OTR tires...''). \\1\\ See Certain New Pneumatic Off-the-Road Tires from the People's Republic of China:...

  15. 75 FR 22742 - New Pneumatic Off-the-Road Tires From the People's Republic of China: Rescission of New Shipper...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-04-30

    ... International Trade Administration New Pneumatic Off-the-Road Tires From the People's Republic of China... antidumping duty order on new pneumatic off-the-road tires (``OTR tires'') from the People's Republic of China... shipper review. See New Pneumatic Off-the-Road Tires from the People's Republic of China: Initiation...

  16. 75 FR 62505 - Certain New Pneumatic Off-the-Road Tires From the People's Republic of China: Notice of Decision...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-10-12

    ... International Trade Administration Certain New Pneumatic Off-the-Road Tires From the People's Republic of China... countervailing duty investigation on certain new pneumatic off-the-road tires (``OTR tires'') from the People's.../exporters of OTR tires from the PRC. See Certain New Pneumatic Off-The-Road-Tires From the People's...

  17. 78 FR 33341 - Certain New Pneumatic Off-the-Road Tires From the People's Republic of China: Final Results of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-06-04

    ... International Trade Administration Certain New Pneumatic Off-the-Road Tires From the People's Republic of China... antidumping duty new shipper review of certain new pneumatic off-the-road tires (``OTR tires'') from the... merchandise at less than normal value. \\1\\ See Certain New Pneumatic Off-the-Road Tires from the...

  18. 75 FR 34098 - Certain New Pneumatic Off-the-Road Tires from the People's Republic of China: Initiation of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-06-16

    ... International Trade Administration Certain New Pneumatic Off-the-Road Tires from the People's Republic of China... new pneumatic off-the- road tires (``OTR tires'') from the People's Republic of China (``PRC... Pneumatic Off-The-Road Tires from the People's Republic of China, Request for Changed Circumstances...

  19. 75 FR 32376 - Certain New Pneumatic Off-the-Road Tires from the People's Republic of China: Preliminary Results...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-06-08

    ... International Trade Administration Certain New Pneumatic Off-the-Road Tires from the People's Republic of China... the antidumping duty order on certain new pneumatic off-the-road (``OTR'') tires from the People's... New Pneumatic Off-the-Road Tires From the People's Republic of China: Notice of Amended...

  20. 78 FR 14267 - Certain New Pneumatic Off-the-Road Tires From the People's Republic of China: Preliminary Results...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-03-05

    ... International Trade Administration Certain New Pneumatic Off-the-Road Tires From the People's Republic of China... on certain new pneumatic off-the-road tires (``OTR tires'') from the People's Republic of China... covered by this order includes new pneumatic tires designed for off-the-road and off-highway use,...

  1. 76 FR 6603 - Certain New Pneumatic Off-the-Road Tires From the People's Republic of China: Notice of Extension...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-02-07

    ... International Trade Administration Certain New Pneumatic Off-the-Road Tires From the People's Republic of China... pneumatic off-the-road tires (``OTR tires'') from the People's Republic of China (``PRC'') for the period... on OTR tires from the PRC. See Certain New Pneumatic Off-the-Road Tires From the People's Republic...

  2. 78 FR 78814 - Certain New Pneumatic Off-the-Road Tires From the People's Republic of China: Initiation and...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-12-27

    ... International Trade Administration Certain New Pneumatic Off-the-Road Tires From the People's Republic of China... the antidumping duty order on certain new pneumatic off-the-road tires (``OTR tires'') from the People... Pneumatic Off-the-Road Tires From the People's Republic of China: Notice of Amended Final...

  3. 75 FR 24884 - Certain New Pneumatic Off-the-Road Tires from the People's Republic of China: Partial Rescission...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-05-06

    ... International Trade Administration Certain New Pneumatic Off-the-Road Tires from the People's Republic of China... Pneumatic Off-the-Road Tires (OTR Tires) from the People's Republic of China (PRC) for the period December...., Tianjin Wanda Tyre Co., Ltd., and Triangle Tyre Co., Ltd. See Certain New Pneumatic Off-the-Road...

  4. 75 FR 46917 - New Pneumatic Off-the-Road Tires from the People's Republic of China: Notice of Partial...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-08-04

    ... International Trade Administration (A-570-912) New Pneumatic Off-the-Road Tires from the People's Republic of... pneumatic off-the-road tires (``OTR tires'') from the People's Republic of China (``PRC'') for the period of... Pneumatic Off-the-Road Tires From the People's Republic of China: Notice of Partial Rescission...

  5. 77 FR 6536 - Certain New Pneumatic Off-the-Road Tires From the People's Republic of China: Notice of Extension...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-02-08

    ... International Trade Administration Certain New Pneumatic Off-the-Road Tires From the People's Republic of China... administrative review of the antidumping duty order on certain new pneumatic off-the-road tires (``off-the-road... administrative review of the antidumping order on off- the-road tires from the PRC. See Certain New Pneumatic......

  6. 78 FR 33059 - Certain New Pneumatic Off-the-Road Tires From the People's Republic of China: Rescission of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-06-03

    ... International Trade Administration Certain New Pneumatic Off-the-Road Tires From the People's Republic of China...'' of the antidumping duty order on certain new pneumatic off-the-road tires from the People's Republic... administrative review of the antidumping duty order on certain new pneumatic off-the-road tires, with respect...

  7. 76 FR 14906 - Certain New Pneumatic Off-the-Road Tires From the People's Republic of China: Notice of Extension...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-03-18

    ... International Trade Administration Certain New Pneumatic Off-the-Road Tires From the People's Republic of China... pneumatic off-the-road tires (``OTR tires'') from the People's Republic of China (``PRC'') for the period... on OTR tires from the PRC. See Certain New Pneumatic Off-the-Road Tires From the People's Republic...

  8. Computed tomography of temporal bone pneumatization. 1. Normal pattern and morphology

    SciTech Connect

    Virapongse, C.; Sarwar, M.; Bhimani, S.; Sasaki, C.; Shapiro, R.

    1985-09-01

    The pneumatization of 141 normal temporal bones on computed tomography (CT) was evaluated in 100 patients. Because of the controversy surrounding the sclerotic squamomastoid (mastoid), temporal bones with this finding were discarded. A CT index of pneumatization was based on the pneumatized area and the number of cells seen within a representative scanning section. Results suggest that squamomastoid pneumatization follows the classic normal distribution and does not correlate with age, gender, or laterality. A high degree of symmetry was found in 41 patients who had both ears examined. Air-cell configuration was variable. Air-cell size tended to increase progressively from the mastoid antrum. The scutum pseudotumor appearance caused by incomplete pneumatization was seen frequently, and should not be mistaken for mastoiditis or an osteoma. Thick sections producing partial-volume effect may also produce this spurious finding. Therefore, when searching for mucosal thickening due to mastoiditis, large air cells should preferably be analyzed.

  9. Real gas effects on charging and discharging processes of high pressure pneumatics

    NASA Astrophysics Data System (ADS)

    Luo, Yuxi; Wang, Xuanyin; Ge, Yaozheng

    2013-01-01

    The high pressure pneumatic system has been applied to special industries. It may cause errors when we analyze high pressure pneumatics under ideal gas assumption. However, the real gas effect on the performances of high pressure pneumatics is seldom investigated. In this paper, the real gas effects on air enthalpy and internal energy are estimated firstly to study the real gas effect on the energy conversion. Under ideal gas assumption, enthalpy and internal energy are solely related to air temperature. The estimation result indicates that the pressure enthalpy and pressure internal energy of real pneumatic air obviously decrease the values of enthalpy and internal energy for high pressure pneumatics, and the values of pressure enthalpy and pressure internal energy are close. Based on the relationship among pressure, enthalpy and internal energy, the real gas effects on charging and discharging processes of high pressure pneumatics are estimated, which indicates that the real gas effect accelerates the temperature and pressure decreasing rates during discharging process, and decelerates their increasing rates during charging process. According to the above analysis, and for the inconvenience in building the simulation model for real gas and the difficulty of measuring the detail thermal capacities of pneumatics, a method to compensate the real gas effect under ideal gas assumption is proposed by modulating the thermal capacity of the pneumatic container in simulation. The experiments of switching expansion reduction (SER) for high pressure pneumatics are used to verify this compensating method. SER includes the discharging process of supply tanks and the charging process of expansion tank. The simulated and experimental results of SER are highly consistent. The proposed compensation method provides a convenient way to obtain more realistic simulation results for high pressure pneumatics.

  10. Prognostics for Ground Support Systems: Case Study on Pneumatic Valves

    NASA Technical Reports Server (NTRS)

    Daigle, Matthew; Goebel, Kai

    2011-01-01

    Prognostics technologies determine the health (or damage) state of a component or sub-system, and make end of life (EOL) and remaining useful life (RUL) predictions. Such information enables system operators to make informed maintenance decisions and streamline operational and mission-level activities. We develop a model-based prognostics methodology for pneumatic valves used in ground support equipment for cryogenic propellant loading operations. These valves are used to control the flow of propellant, so failures may have a significant impact on launch availability. Therefore, correctly predicting when valves will fail enables timely maintenance that avoids launch delays and aborts. The approach utilizes mathematical models describing the underlying physics of valve degradation, and, employing the particle filtering algorithm for joint state-parameter estimation, determines the health state of the valve and the rate of damage progression, from which EOL and RUL predictions are made. We develop a prototype user interface for valve prognostics, and demonstrate the prognostics approach using historical pneumatic valve data from the Space Shuttle refueling system.

  11. Performance optimization of a pneumatic wave energy conversion device

    NASA Astrophysics Data System (ADS)

    Surko, S. W.

    1982-08-01

    The purpose of this study was, for the first time, to optimize the performance of a pneumatic wave energy conversion device. The experiments of Jolly and Newmaster (1979) and Trop and Casey (1980) left a capture chamber and turbine for further investigation. To optimize the system performance the turbine had to be first analyzed so that its power performance curves could be determined. These curves were needed to help define the possible overall performance of the system, and for the impedance matching of the system necessary for performance optimization. With this knowledge, an appropriate generator was purchased and a generator-turbine linkage designed and built. The completed system was then analyzed in the 380 ft wave tank at the U.S. Naval Academy to establish its optimum performance. From the research it is clear that pneumatic wave energy conversion is a promising concept. With several hundred of these devices situated some 100 km off the coast of the Pacific Northwest each device would be producing from 50 to 200 kW which would be transferred back to shore.

  12. Pneumatic oscillator circuits for timing and control of integrated microfluidics.

    PubMed

    Duncan, Philip N; Nguyen, Transon V; Hui, Elliot E

    2013-11-01

    Frequency references are fundamental to most digital systems, providing the basis for process synchronization, timing of outputs, and waveform synthesis. Recently, there has been growing interest in digital logic systems that are constructed out of microfluidics rather than electronics, as a possible means toward fully integrated laboratory-on-a-chip systems that do not require any external control apparatus. However, the full realization of this goal has not been possible due to the lack of on-chip frequency references, thus requiring timing signals to be provided from off-chip. Although microfluidic oscillators have been demonstrated, there have been no reported efforts to characterize, model, or optimize timing accuracy, which is the fundamental metric of a clock. Here, we report pneumatic ring oscillator circuits built from microfluidic valves and channels. Further, we present a compressible-flow analysis that differs fundamentally from conventional circuit theory, and we show the utility of this physically based model for the optimization of oscillator stability. Finally, we leverage microfluidic clocks to demonstrate circuits for the generation of phase-shifted waveforms, self-driving peristaltic pumps, and frequency division. Thus, pneumatic oscillators can serve as on-chip frequency references for microfluidic digital logic circuits. On-chip clocks and pumps both constitute critical building blocks on the path toward achieving autonomous laboratory-on-a-chip devices.

  13. MarsVac: Pneumatic Sampling System for Planetary Exploration

    NASA Astrophysics Data System (ADS)

    Zacny, K.; Mungas, G.; Chu, P.; Craft, J.; Davis, K.

    2008-12-01

    We are proposing a Mars Sample Return scheme whereby a sample of regolith is acquired directly into a Mars Ascent Vehicle using a pneumatic system. Unlike prior developments that used suction to collect fines, the proposed system uses positive pressure to move the regolith. We envisage 3 pneumatic tubes to be embedded inside the 3 legs of the lander. Upon landing, the legs will burry themselves into the regolith and the tubes will fill up with regolith. With one puff of gas, the regolith can be lifted into a sampling chamber onboard of the Mars Ascent Vehicle. An additional chamber can be opened to acquire atmospheric gas and dust. The entire MSR will require 1) an actuator to open/close sampling chamber and 2) a valve to open gas cylinder. In the most recent study related to lunar excavation and funded under the NASA SBIR program we have shown that it is possible lift over 3000 grams of soil with only 1 gram of gas at 1atm. Tests conducted under Mars atmospheric pressure conditions (5 torr). In September of 2008, we will be performing tests at 1/6thg (Moon) and 1/3g (Mars) to determine mass lifting efficiencies in reduced gravities.

  14. Independence of biomechanical forces and craniofacial pneumatization in Cebus.

    PubMed

    Rae, Todd C; Koppe, Thomas

    2008-11-01

    Several different factors have been hypothesized as explanations of variation in primate paranasal sinus size. Biomechanical forces, particularly those associated with mastication, are frequently evoked to account for differences in primate craniofacial pneumatization. To test whether masticatory stresses are responsible for maxillary sinus volume diversity, two platyrrhine species of the genus Cebus (C. apella and C. albifrons) were examined. The former has been identified as a hard object feeder, and many morphological differences between the two species are attributable to differences in the mechanical properties of their respective diets. Sinus volumes were derived from serial coronal CT scans of the crania of adults. Several external cranial measurements were used to scale sinus volume relative to the size of the face. Relative measures of maxillary sinus volume were compared using standard statistical techniques. In all comparisons, the two capuchin species do not differ from one another significantly at P < 0.05. Thus, this "natural experiment" fails to support the interpretation that biomechanical forces acting on the facial skeleton substantially affect the degree of paranasal pneumatization in primates. This result suggests that it is unlikely that the maxillary sinus performs any function in relation to masticatory stress; other factors must be responsible for the variation in sinus volume among primates.

  15. Development of an Air Pneumatic Suspension System for Transtibial Prostheses

    PubMed Central

    Pirouzi, Gholamhossein; Osman, Noor Azuan Abu; Oshkour, Azim Ataollahi; Ali, Sadeeq; Gholizadeh, Hossein; Wan Abas, Wan A. B.

    2014-01-01

    The suspension system and socket fitting of artificial limbs have major roles and vital effects on the comfort, mobility, and satisfaction of amputees. This paper introduces a new pneumatic suspension system that overcomes the drawbacks of current suspension systems in donning and doffing, change in volume during daily activities, and pressure distribution in the socket-stump interface. An air pneumatic suspension system (APSS) for total-contact sockets was designed and developed. Pistoning and pressure distribution in the socket-stump interface were tested for the new APSS. More than 95% of the area between each prosthetic socket and liner was measured using a Tekscan F-Scan pressure measurement which has developed matrix-based pressure sensing systems. The variance in pressure around the stump was 8.76 kPa. APSS exhibits less pressure concentration around the stump, improved pressure distribution, easy donning and doffing, adjustability to remain fitted to the socket during daily activities, and more adaptability to the changes in stump volume. The volume changes were adjusted by utility of air pressure sensor. The vertical displacement point and reliability of suspension were assessed using a photographic method. The optimum pressure in every level of loading weight was 55 kPa, and the maximum displacement was 6 mm when 90 N of weight was loaded. PMID:25207872

  16. Pneumatic interactive gait rehabilitation orthosis: design and preliminary testing.

    PubMed

    Belforte, G; Eula, G; Appendino, S; Sirolli, S

    2011-02-01

    Motor rehabilitation techniques based on passive movement of the lower limbs have been developed over the past 15 years. Gait training automation is the latest innovation in these techniques. This paper describes the design and development of a pneumatic interactive gait rehabilitation orthosis (PIGRO), as well as the first experimental results obtained with healthy subjects. PIGRO consists of a modular and size-adaptable exoskeleton, pneumatic actuation systems for the six actuated degrees of freedom (DoF), and a control unit. The foot orthosis and ankle actuation can be removed and/or replaced with orthopaedic shoes so as to permit gait rehabilitation while advancing between parallel bars with ground contact and partial body weight support (i.e. not walking in place). Control logic provides closed-loop position control independently on each joint, with position feedback for each joint in real time. Imposed curves are physiological joint angles: it is also possible to choose between activating one or both legs and to modify curves to obtain different gait patterns if required. The paper concludes with a presentation of experimental results for the device's performance.

  17. THE RABBIT ZYGOTE

    PubMed Central

    Gulyas, Bela J.

    1972-01-01

    The formation of the blastomere nucleus was examined in the rabbit zygote with the electron microscope. In late anaphase the chromosomes are bare and vesicles of the smooth endoplasmic reticulum are numerous in the vicinity of the chromosomes. In early telophase individual chromosomes attain their own nuclear envelope and they are called karyomeres. The envelope of the karyomeres contains small gaps within it at several places where the chromatin is exposed to the cytoplasm. Nuclear pores are also observed. In the cytoplasm short annulate lamellae appear adjacent to the karyomeres, and clusters of punctate substance are also present. From early telophase onward the karyomeres extend pseudopod-like structures, called karyopods, which extend toward other karyomeres or karyopods, and consequently fuse together and serve as chromosomal bridges. Eventually all of the karyomeres fuse into a dense nucleus and decondensation of the chromosomes occurs. PMID:4676367

  18. The cottontail rabbits of Virginia

    USGS Publications Warehouse

    Llewellyn, L.M.; Handley, C.O.

    1945-01-01

    Five races of cottontail rabbits belonging to three species occur in Virginia. One of them, the Mearns cottontail (Sylvilagus floridanus mearnsi), is reported here for the first time. It occurs in six southwestern counties of the state, while the eastern cottontail (S. f. mallurus) occurs in the remainder of the state with the exception of Smith and Fishermans islands off the eastern coast of Cape Charles, where it is replaced by Hitchens cottontail (S. f. hitchensi). The New England cottontail (S. transitionalis) is found on the higher mountain peaks, above 3000 feet, and the swamp rabbit (S. palustris) occurs in the Dismal Swamp region of southeastern Virginia.....The height of the breeding season for the eastern cottontail in Virginia is March and April, but breeding continues through the entire year except in December and January. The average litter size based on embryo counts was 4.7. The sex ratio of 234 specimens from all parts of the state, taken mostly in the December to February period, was 53 males to 47 females. That of a group of 145 rabbits live-trapped at Blacksburg during February and Marchwas 58 males to 42 females. The figures show that males are more active than females during the winter months, and therefore are more easily taken then....In transplanting cottontails from one section of the state to another, it is recommended that only cottontails of the same race as those originally present in the region being restocked be released there....Tularemia is not a common disease among rabbits in Virginia, but the rabbit ticks are often carriers of the disease and may transmit it to rabbits. Rabbit ticks are also found to be carriers of Rocky Mountain fever and American Q. fever. After the ticks drop off the rabbits to hibernate in the ground, which is likely to occur during mid-winter in Virginia, there is relatively little danger of humans contracting tularemia by contact with rabbits. Present laws in Virginia which prohibit rabbit hunting until the

  19. Dynamic Friction Performance of a Pneumatic Cylinder with Al2O3 Film on Cylinder Surface.

    PubMed

    Chang, Ho; Lan, Chou-Wei; Wang, Hao-Xian

    2015-11-01

    A friction force system is proposed for accurately measuring friction force and motion properties produced by reciprocating motion of piston in a pneumatic cylinder. In this study, the proposed system is used to measure the effects of lubricating greases of different viscosities on the friction properties of pneumatic cylinder, and improvement of stick-slip motion for the cylinder bore by anodizing processes. A servo motor-driven ball screw is used to drive the pneumatic cylinder to be tested and to measure the change in friction force of the pneumatic cylinder. Experimental results show, that under similar test conditions, the lubricating grease with viscosity VG100 is best suited for measuring reciprocating motion of the piston of pneumatic cylinder. The wear experiment showed that, in the Al2O3 film obtained at a preset voltage 40 V in the anodic process, the friction coefficient and hardness decreased by 55% and increased by 274% respectively, thus achieving a good tribology and wear resistance. Additionally, the amplitude variation in the friction force of the pneumatic cylinder wall that received the anodizing treatment was substantially reduced. Additionally, the stick-slip motion of the pneumatic cylinder during low-speed motion was substantially improved. PMID:26726680

  20. Lens hexokinase deactivation by near-UV irradiation.

    PubMed

    Tung, W H; Chylack, L T; Andley, U P

    1988-03-01

    Photodamage to lens hexokinase has been investigated by exposing the lenses of rat, rabbit and calf eyes to 300 nm irradiation. Hexokinase activity was diminished by 15.9% +/- 5.4 and 23.4% +/- 5.0 upon irradiation of the isolated rat lens for 1 and 2 hours respectively. Irradiation of the whole eye for 2 hours resulted in hexokinase deactivation of 13.6% +/- 5.8 and 19.2% +/- 6.2 for rat and rabbit lens homogenates and 55% +/- 7 for calf lens capsule plus epithelium. Enzyme deactivation was prevented when the isolated lens was irradiated with the vitreous attached. Glucose, catalase or ascorbate added to the medium prior to irradiation, each had a protective effect on hexokinase deactivation. The results are consistent with a mechanism in which photochemical generation of active species of oxygen, via the photosensitizing action of tryptophan photoproducts, plays a significant role in enzyme deactivation. PMID:3359812

  1. The role of particle collisions in pneumatic transport

    NASA Technical Reports Server (NTRS)

    Mastorakos, E.; Louge, M.; Jenkins, J. T.

    1989-01-01

    A model of dilute gas-solid flow in vertical risers is developed in which the particle phase is treated as a granular material, the balance equations for rapid granular flow are modified to incorporate the drag force from the gas, and boundary conditions, based on collisional exchanges of momentum and energy at the wall, are employed. In this model, it is assumed that the particle fluctuations are determined by inter-particle collisions only and that the turbulence of the gas is unaffected by the presence of the particles. The model is developed in the context of, but not limited to, steady, fully developed flow. A numerical solution of the resulting governing equations provides concentration profiles generally observed in dilute pneumatic flow, velocity profiles in good agreement with the measurements of Tsuji, et al. (1984), and an explanation for the enhancement of turbulence that they observed.

  2. A high performance pneumatic braking system for heavy vehicles

    NASA Astrophysics Data System (ADS)

    Miller, Jonathan I.; Cebon, David

    2010-12-01

    Current research into reducing actuator delays in pneumatic brake systems is opening the door for advanced anti-lock braking algorithms to be used on heavy goods vehicles. However, these algorithms require the knowledge of variables that are impractical to measure directly. This paper introduces a sliding mode braking force observer to support a sliding mode controller for air-braked heavy vehicles. The performance of the observer is examined through simulations and field testing of an articulated heavy vehicle. The observer operated robustly during single-wheel vehicle simulations, and provided reasonable estimates of surface friction from test data. The effect of brake gain errors on the controller and observer are illustrated, and a recursive least squares estimator is derived for the brake gain. The estimator converged within 0.3 s in simulations and vehicle trials.

  3. Design of a biped robot actuated by pneumatic artificial muscles.

    PubMed

    Liu, Yixiang; Zang, Xizhe; Liu, Xinyu; Wang, Lin

    2015-01-01

    High compliant legs are essential for the efficient versatile locomotion and shock absorbency of humans. This study proposes a biped robot actuated by pneumatic artificial muscles to mimic human locomotion. On the basis of the musculoskeletal architecture of human lower limbs, each leg of the biped robot is modeled as a system of three segments, namely, hip joint, knee joint, and ankle joint, and eleven muscles, including both monoarticular and biarticular muscles. Each rotational joint is driven by a pair of antagonistic muscles, enabling joint compliance to be tuned by operating the pressure inside the muscles. Biarticular muscles play an important role in transferring power between joints. Walking simulations verify that biarticular muscles contribute to joint compliance and can absorb impact energy when the robot makes an impact upon ground contact. PMID:26406072

  4. Design of a biped robot actuated by pneumatic artificial muscles.

    PubMed

    Liu, Yixiang; Zang, Xizhe; Liu, Xinyu; Wang, Lin

    2015-01-01

    High compliant legs are essential for the efficient versatile locomotion and shock absorbency of humans. This study proposes a biped robot actuated by pneumatic artificial muscles to mimic human locomotion. On the basis of the musculoskeletal architecture of human lower limbs, each leg of the biped robot is modeled as a system of three segments, namely, hip joint, knee joint, and ankle joint, and eleven muscles, including both monoarticular and biarticular muscles. Each rotational joint is driven by a pair of antagonistic muscles, enabling joint compliance to be tuned by operating the pressure inside the muscles. Biarticular muscles play an important role in transferring power between joints. Walking simulations verify that biarticular muscles contribute to joint compliance and can absorb impact energy when the robot makes an impact upon ground contact.

  5. Analysis of nonlinear elastic behavior in miniature pneumatic artificial muscles

    NASA Astrophysics Data System (ADS)

    Hocking, Erica G.; Wereley, Norman M.

    2013-01-01

    Pneumatic artificial muscles (PAMs) are well known for their excellent actuator characteristics, including high specific work, specific power, and power density. Recent research has focused on miniaturizing this pneumatic actuator technology in order to develop PAMs for use in small-scale mechanical systems, such as those found in robotic or aerospace applications. The first step in implementing these miniature PAMs was to design and characterize the actuator. To that end, this study presents the manufacturing process, experimental characterization, and analytical modeling of PAMs with millimeter-scale diameters. A fabrication method was developed to consistently produce low-cost, high performance, miniature PAMs using commercially available materials. The quasi-static behavior of these PAMs was determined through experimentation on a single actuator with an active length of 39.16 mm (1.54 in) and a diameter of 4.13 mm (0.1625 in). Testing revealed the PAM’s full evolution of force with displacement for operating pressures ranging from 207 to 552 kPa (30-80 psi in 10 psi increments), as well as the blocked force and free contraction at each pressure. Three key nonlinear phenomena were observed: nonlinear PAM stiffness, hysteresis of the force versus displacement response for a given pressure, and a pressure deadband. To address the analysis of the nonlinear response of these miniature PAMs, a nonlinear stress versus strain model, a hysteresis model, and a pressure bias are introduced into a previously developed force balance analysis. Parameters of these nonlinear model refinements are identified from the measured force versus displacement data. This improved nonlinear force balance model is shown to capture the full actuation behavior of the miniature PAMs at each operating pressure and reconstruct miniature PAM response with much more accuracy than previously possible.

  6. Validity and reliability of a controlled pneumatic resistance exercise device.

    PubMed

    Paulus, David C; Reynolds, Michael C; Schilling, Brian K

    2008-01-01

    During the concentric portion of the free-weight squat exercise, accelerating the mass from rest results in a fluctuation in ground reaction force. It is characterized by an initial period of force greater than the load while accelerating from rest followed by a period of force lower than the external load during negative acceleration. During the deceleration phase, less force is exerted and muscles are loaded sub-optimally. Thus, using a reduced inertia form of resistance such as pneumatics has the capability to minimize these inertial effects as well as control the force in real time to maximize the force exerted over the exercise cycle. To improve the system response of a preliminary design, a squat device was designed with a reduced mass barbell and two smaller pneumatic cylinders. The resistance was controlled by regulating cylinder pressure such that it is capable of adjusting force within a repetition to maximize force exerted during the lift. The resistance force production of the machine was statically validated with the input voltage and output force R2 =0.9997 for at four increments of the range of motion, and the intraclass correlation coefficient (ICC) between trials at the different heights equaled 0.999. The slew rate at three forces was 749.3 N/s +/- 252.3. Dynamic human subject testing showed the desired input force correlated with average and peak ground reaction force with R2 = 0.9981 and R2 = 0.9315, respectively. The ICC between desired force and average and peak ground reaction force was 0.963. Thus, the system is able to deliver constant levels of static and dynamic force with validity and reliability. Future work will be required to develop the control strategy required for real-time control, and performance testing is required to determine its efficacy.

  7. [The scintigraphic assessment of the patients suffering from cardia achalasia, treated by pneumatic dilatation].

    PubMed

    Stan, Mărioara; Bălan, G; Rusu, Maria; Ciortescu, Irina; Popa, Florentina

    2002-01-01

    The esophageal scintigraphy is a technique used to evaluate the motility and the clearance of the esophagus. The patients with achalasia of the cardia were evaluated, before treating them with pneumatic dilatation and after. The reason is to evaluate the efficiency of the pneumatic dilatation technique in the treatment of esophageal achalasia. The pneumatic dilatation with an instrument type Rigiflex is a well/handled and used technique in our clinic. In the study 22 patients were included and we had in view the esophageal transit time and the residuary radioactivity before and after the pneumatic dilatation. We established an important statistical improvement of the data obtained after the dilatation comparative with the data before the treatment (p < 0.01). PMID:12638275

  8. Teaching Mathematical and Scientific Concepts through the Use of a Pneumatic Arm Wrestling Machine.

    ERIC Educational Resources Information Center

    Johnson, William W., Jr.

    1994-01-01

    Describes a learning activity in which students build a pneumatic arm wrestling machine, thus combining their interest in arm wrestling while making direct applications to many scientific and mathematical concepts. (JOW)

  9. An investigation of the effects of pneumatic actuator design on slip control for heavy vehicles

    NASA Astrophysics Data System (ADS)

    Miller, Jonathan I.; Cebon, David

    2013-01-01

    Progress in reducing actuator delays in pneumatic brake systems is opening the door for advanced anti-lock braking algorithms to be used on heavy goods vehicles. However, little has been published on slip controllers for air-braked heavy vehicles, or the effects of slow pneumatic actuation on their design and performance. This paper introduces a sliding mode slip controller for air-braked heavy vehicles. The effects of pneumatic actuator delays and flow rates on stopping performance and air (energy) consumption are presented through vehicle simulations. Finally, the simulations are validated with experiments using a hardware-in-the-loop rig. It is shown that for each wheel, pneumatic valves with delays smaller than 3 ms and orifice diameters around 8 mm provide the best performance.

  10. Application of Model-based Prognostics to a Pneumatic Valves Testbed

    NASA Technical Reports Server (NTRS)

    Daigle, Matthew; Kulkarni, Chetan S.; Gorospe, George

    2014-01-01

    Pneumatic-actuated valves play an important role in many applications, including cryogenic propellant loading for space operations. Model-based prognostics emphasizes the importance of a model that describes the nominal and faulty behavior of a system, and how faulty behavior progresses in time, causing the end of useful life of the system. We describe the construction of a testbed consisting of a pneumatic valve that allows the injection of faulty behavior and controllable fault progression. The valve opens discretely, and is controlled through a solenoid valve. Controllable leaks of pneumatic gas in the testbed are introduced through proportional valves, allowing the testing and validation of prognostics algorithms for pneumatic valves. A new valve prognostics approach is developed that estimates fault progression and predicts remaining life based only on valve timing measurements. Simulation experiments demonstrate and validate the approach.

  11. Costs and benefits of pneumatic collection in three specific New York City cases

    SciTech Connect

    Miller, Benjamin; Spertus, Juliette; Kamga, Camille

    2014-11-15

    Highlights: • Pneumatic and truck collection were compared in three New York City locations. • Relative costs, energy use, and greenhouse gas emissions varied significantly. • Variations were due to location-specific factors (e.g., route density, truck type). • Under appropriate conditions, pneumatic collection reduces TMT, BTU, and GHG. • Pneumatic capex may be offset by operating savings and externality benefits. - Abstract: Truck-based collection of municipal solid waste imposes significant negative externalities on cities and constrains the efficiency of separate collection of recyclables and organics and of unit-price-based waste-reduction systems. In recent decades, hundreds of municipal-scale pneumatic collection systems have been installed in Europe and Asia. Relatively few prior studies have compared the economic or environmental impacts of these systems to those of truck collection. A critical factor to consider when making this comparison is the extent to which the findings reflect the specific geographic, demographic, and operational characteristics of the systems considered. This paper is based on three case studies that consider the specific characteristics of three locations, comparing pneumatic systems with conventional collection on the basis of actual waste tonnages, composition, sources, collection routes, truck trips, and facility locations. In one case, alternative upgrades to an existing pneumatic system are compared to a potential truck-collection operation. In the other cases, existing truck operations are compared to proposed pneumatic systems which, to reduce capital costs, would be installed without new trenching or tunneling through the use of existing linear infrastructure. For the two proposed retrofit pneumatic systems, up to 48,000 truck kilometers travelled would be avoided and energy use would be reduced by up to 60% at an incremental cost of up to $400,000 USD per year over the total operating-plus-capital cost of

  12. Costs and benefits of pneumatic collection in three specific New York City cases.

    PubMed

    Miller, Benjamin; Spertus, Juliette; Kamga, Camille

    2014-11-01

    Truck-based collection of municipal solid waste imposes significant negative externalities on cities and constrains the efficiency of separate collection of recyclables and organics and of unit-price-based waste-reduction systems. In recent decades, hundreds of municipal-scale pneumatic collection systems have been installed in Europe and Asia. Relatively few prior studies have compared the economic or environmental impacts of these systems to those of truck collection. A critical factor to consider when making this comparison is the extent to which the findings reflect the specific geographic, demographic, and operational characteristics of the systems considered. This paper is based on three case studies that consider the specific characteristics of three locations, comparing pneumatic systems with conventional collection on the basis of actual waste tonnages, composition, sources, collection routes, truck trips, and facility locations. In one case, alternative upgrades to an existing pneumatic system are compared to a potential truck-collection operation. In the other cases, existing truck operations are compared to proposed pneumatic systems which, to reduce capital costs, would be installed without new trenching or tunneling through the use of existing linear infrastructure. For the two proposed retrofit pneumatic systems, up to 48,000 truck kilometers travelled would be avoided and energy use would be reduced by up to 60% at an incremental cost of up to $400,000 USD per year over the total operating-plus-capital cost of conventional collection. In the location where a greenfield pneumatic system is already in operation, truck collection would be both less expensive and more energy-efficient than pneumatic collection. The results demonstrate that local geographic, demographic, and operational conditions play a decisive role in determining whether pneumatic collection will reduce energy requirements, produce more or fewer greenhouse gas emissions, and cost more

  13. Pneumatic motor powered Thrust Vector Control (TVC) for liquid propelled launch vehicles

    NASA Astrophysics Data System (ADS)

    Malone, Mark C.; Evans, P. S.

    1992-02-01

    Recent studies performed for the Titan 4 launch vehicle indicate significant potential advantages in replacing the current stage 1 and 2 recirculating hydraulic TVC (thrust vector control) system with a PMA (pneumatic mechanical actuation) system. Some of the advantages of a PMA system over the recirculating hydraulic system include reduced part count and weight, reduced maintenance and life-cycle cost, and improved mission reliability. PMA technology, used in aircraft applications since the 1960s, is well suited in launch vehicle TVC applications where an existing pneumatic pressure source is available. A typical pneumatic motor TVC consists of a pneumatic power source, a dual rotor pneumatic motor, a gear box, a ball screw actuator, and the associated closed-loop servo-control elements. One key issue with implementing this mechanical approach is designing a TVC system to withstand large load transient disturbances during liquid engine starting. Hydraulic actuator transient loads have exceeded 60,000 lb(sub f) for a 30,000 lb(sub f) stall design actuator during ground starts of the Titan 3B, Stage 1 engine. A PMA TVC system must also withstand these start transients without imparting excessive reaction loads to the engine nozzle and thrust structure. Work completed to date with Martin Marietta to examine pneumatic motor powered TVC options and technology benefits is presented. The load transient issue is discussed along with potential solutions and the associated trades. General background on PMA technology and experience base is also presented.

  14. [The forensic medical characteristics of the entrance bullet holes created by the shots from pneumatic rifles].

    PubMed

    Legin, G A; Bondarchuk, A O; Perebetiuk, A N

    2015-01-01

    The objective of the present study was to compare the injurious action of three types of the bullets for the pneumatic weapons shot from different distances using the Gamo pump air pistol and the BAM B22-1 pneumatic rifle. The following four kinds of the bullets were tested: "the fireball", "Luman cap 0.3", "Luman Field Target 0.68" and "DIABOLO". It was experimentally shown that the injurious action of the bullets fired from the same distance from the pneumatic weapons depends on the type of both the bullet and the weapon, as well as the properties of the target material. Specifically, the action of bullets fired from the piston pneumatic rifle remained stable whereas that of the bullets shot from the gas-balloon air pistol decreased as the gas was exhausted. The studies by the contact-diffusion method have demonstrated that the entrance bullet holes created by the shots from pneumatic weapons are surrounded by dispersed metal particles which makes it possible to estimate the shooting distance. Moreover, the bullets fired from the pneumatic weapons leave the muzzle face imprint on certain target materials.

  15. [The forensic medical characteristics of the entrance bullet holes created by the shots from pneumatic rifles].

    PubMed

    Legin, G A; Bondarchuk, A O; Perebetiuk, A N

    2015-01-01

    The objective of the present study was to compare the injurious action of three types of the bullets for the pneumatic weapons shot from different distances using the Gamo pump air pistol and the BAM B22-1 pneumatic rifle. The following four kinds of the bullets were tested: "the fireball", "Luman cap 0.3", "Luman Field Target 0.68" and "DIABOLO". It was experimentally shown that the injurious action of the bullets fired from the same distance from the pneumatic weapons depends on the type of both the bullet and the weapon, as well as the properties of the target material. Specifically, the action of bullets fired from the piston pneumatic rifle remained stable whereas that of the bullets shot from the gas-balloon air pistol decreased as the gas was exhausted. The studies by the contact-diffusion method have demonstrated that the entrance bullet holes created by the shots from pneumatic weapons are surrounded by dispersed metal particles which makes it possible to estimate the shooting distance. Moreover, the bullets fired from the pneumatic weapons leave the muzzle face imprint on certain target materials. PMID:26036066

  16. Development of myopia as a hazard for workers in pneumatic caissons

    PubMed Central

    Onoo, A; Kiyosawa, M; Takase, H; Mano, Y

    2002-01-01

    Background/aim: Pneumatic caisson engineering has been developed for large civil engineering constructions. Because of complaints of blurred vision by personnel working in pneumatic caissons, the development of myopia was suspected. The aim of this study was to determine the cause of the blurred vision and the mechanism underlying the changes. Methods: 12 caisson workers underwent a complete ophthalmological examination after completing up to 11 weeks of work (4 days/week) in a pneumatic caisson. Six months later, nine of the workers were examined again. Results: Nine subjects were myopic at the initial examination, and seven of these were considered to have developed the myopia after starting to work in the pneumatic caisson. Six months after completion of the work, the mean refractive change was significantly towards hyperopia. Conclusions: The blurred vision in pneumatic caisson workers was in all likelihood due to the development of myopia. The refractive shift towards hyperopia after completion of work in the pneumatic caisson supports this and demonstrates that the changes were temporary. The myopia is similar to the myopia seen in patients treated by hyperbaric oxygen. Careful monitoring of the refraction of caisson workers should be performed for industrial health control. PMID:12386088

  17. Field and numerical determinations of pneumatic flow parameters of unsaturated fractured porous rocks on various scales

    NASA Astrophysics Data System (ADS)

    Guillon, S.; Vu, M. T.; Pili, E.; Adler, P. M.

    2013-05-01

    Air permeability is measured in the fractured crystalline rocks of the Roselend Natural Laboratory (France). Single-hole pneumatic injection tests as well as differential barometric pressure monitoring are conducted on scales ranging from 1 to 50 m, in both shallow and deep boreholes, as well as in an isolated 60 m3 chamber at 55 m depth. The field experiments are interpreted using numerical simulations in equivalent homogeneous porous media with their real 3-D geometry in order to estimate pneumatic parameters. For pneumatic injection tests, steady-state data first allow to estimate air permeability. Then, pressure recovery after a pneumatic injection test allows to estimate the air-filled porosity. Comparison between the various studied cases clarifies the influence of the boundary conditions on the accuracy of the often used 1-D estimate of air permeability. It also shows that permeabilities correlate slightly with fracture density. In the chamber, a 1 order-of-magnitude difference is found between the air permeabilities obtained from pneumatic injection tests and from differential barometric pressure monitoring. This discrepancy is interpreted as a scale effect resulting from the approximation of the heterogeneous fractured rock by a homogeneous numerical model. The difference between the rock volumes investigated by pneumatic injection tests and by differential barometric pressure monitoring may also play a role. No clear dependence of air permeability on saturation has been found so far.

  18. Teratology studies in the rabbit.

    PubMed

    Allais, Linda; Reynaud, Lucie

    2013-01-01

    The rabbit is generally the non-rodent species or second species after the rat recommended by the regulatory authorities and is part of the package of regulatory reproductive studies for the detection of potential embryotoxic and/or teratogenic effects of pharmaceuticals, chemicals, food additives, and other compounds, including vaccines (see Chapters 1-7).Its availability, practicality in housing and in mating as well as its large size makes the rabbit the preferred choice as a non-rodent species. The study protocols are essentially similar to those established for the rat (Chapter 9), with some particularities. The study designs are well defined in guidelines and are relatively standardized between testing laboratories across the world.As for the rat, large litter sizes and extensive background data in the rabbit are valuable criteria for an optimal assessment of in utero development of the embryo or fetus and for the detection of potential external or internal fetal malformations.

  19. Differential Fault Analysis of Rabbit

    NASA Astrophysics Data System (ADS)

    Kircanski, Aleksandar; Youssef, Amr M.

    Rabbit is a high speed scalable stream cipher with 128-bit key and a 64-bit initialization vector. It has passed all three stages of the ECRYPT stream cipher project and is a member of eSTREAM software portfolio. In this paper, we present a practical fault analysis attack on Rabbit. The fault model in which we analyze the cipher is the one in which the attacker is assumed to be able to fault a random bit of the internal state of the cipher but cannot control the exact location of injected faults. Our attack requires around 128 - 256 faults, precomputed table of size 241.6 bytes and recovers the complete internal state of Rabbit in about 238 steps.

  20. European Rabbits as Reservoir for Coxiella burnetii.

    PubMed

    González-Barrio, David; Maio, Elisa; Vieira-Pinto, Madalena; Ruiz-Fons, Francisco

    2015-06-01

    We studied the role of European rabbits (Oryctolagus cuniculus) as a reservoir for Coxiella burnetii in the Iberian region. High individual and population seroprevalences observed in wild and farmed rabbits, evidence of systemic infections, and vaginal shedding support the reservoir role of the European rabbit for C. burnetii.

  1. European Rabbits as Reservoir for Coxiella burnetii.

    PubMed

    González-Barrio, David; Maio, Elisa; Vieira-Pinto, Madalena; Ruiz-Fons, Francisco

    2015-06-01

    We studied the role of European rabbits (Oryctolagus cuniculus) as a reservoir for Coxiella burnetii in the Iberian region. High individual and population seroprevalences observed in wild and farmed rabbits, evidence of systemic infections, and vaginal shedding support the reservoir role of the European rabbit for C. burnetii. PMID:25988670

  2. Arsanilic acid toxicity in rabbits.

    PubMed

    Confer, A W; Ward, B C; Hines, F A

    1980-04-01

    Rations from several rabbitries experiencing increased mortality, weight loss and diminished reproduction were analyzed for arsanilic acid. Levels of less than 56 ppm of arsanilic acid were found. A 30 day trial was conducted where arsanilic acid was given in doses of 1.6-16.2 mg/day in water to weanling and adult rabbits. The higher doses induced diarrhea, terminal convulsions and death. Weight loss or reduced weight gains occurred in six of seven treated groups. No significant gross or microscopic lesions were observed. Chemical analysis demonstrated the presence of increased total hepatic arsenic levels in treated compared to control rabbits.

  3. [Formation of liquid crystal structures in the tissue fluid in wound healing during periodic irradiation with helium-neon laser].

    PubMed

    Mints, R I; Skopinov, S A; Iakovleva, S V; Lisienko, V M; Drobinina, O V

    1989-01-01

    Rabbit tissue fluid at different stages of wound healing was studied. Interaction between the formation of liquid crystalline fractions and the course of healing was revealed both under natural conditions and under periodic laser irradiation of the wound.

  4. Acute Radiation Hypotension in the Rabbit: a Model for the Human Radiation Shock Syndrome.

    NASA Astrophysics Data System (ADS)

    Makale, Milan Theodore

    This study has shown that total body irradiation (TBI) of immature (40 to 100 day old) rabbits leads to an acute fall in mean arterial pressure (MAP) 30 to 90 minutes after exposure, which takes no more than about three minutes, and often results in pressures which are less than 50% of the lowest pre-exposure MAP. This is termed acute cardiovascular collapse (ACC). ACC is often accompanied by ECG T-wave elevation, a sharp rise in ear temperature, labored breathing, pupillary constriction, bladder emptying, and loss of abdominal muscle tone. About 73% of 40 to 100 day rabbits exhibit ACC; the others and most older rabbits display gradual pressure reductions (deliberate hypotension) which may be profound, and which may be accompanied by the same changes associated with ACC. ACC and deliberate hypotension occurred in rabbits cannulated in the dorsal aorta, and in non-operated animals. The decline in MAP for all 40 to 100 day cannulated rabbits (deliberate and ACC responders) is 55.4%. The experiments described below only involved 40 to 100 day cannulated TBI rabbits. Heart region irradiation resulted in an average MAP decline of 29.1%, with 1/15 rabbits showing ACC. Heart shielding during TBI reduced the decline in MAP to 19%, with 1/10 rabbits experiencing ACC. These results imply that the heart region, which includes the heart, part of the lungs, neural receptors, roots of the systemic vessels, and the blood, is a sensitive target. Bilateral vagotomy reduced the decline in MAP to 24.9%, and abolished ACC. Atropine (6 mg/kg) reduced the frequency of ACC to 26%, and the decline in MAP to 41.4%. In 11/13 rabbits the voltage generated by left vagal transmission rose after TBI. The vagi appear to participate in radiation hypotension. Heart shielding together with bilateral vagotomy reduced the decline in MAP to only 9.9%, with no ACC responders. The mean right ventricular pressure (MRVP) rose after TBI in 8/10 rabbits. In animals which displayed either ACC or steep

  5. Reversible thermo-pneumatic valves on centrifugal microfluidic platforms.

    PubMed

    Aeinehvand, Mohammad Mahdi; Ibrahim, Fatimah; Harun, Sulaiman Wadi; Kazemzadeh, Amin; Rothan, Hussin A; Yusof, Rohana; Madou, Marc

    2015-08-21

    Centrifugal microfluidic systems utilize a conventional spindle motor to automate parallel biochemical assays on a single microfluidic disk. The integration of complex, sequential microfluidic procedures on these platforms relies on robust valving techniques that allow for the precise control and manipulation of fluid flow. The ability of valves to consistently return to their former conditions after each actuation plays a significant role in the real-time manipulation of fluidic operations. In this paper, we introduce an active valving technique that operates based on the deflection of a latex film with the potential for real-time flow manipulation in a wide range of operational spinning speeds. The reversible thermo-pneumatic valve (RTPV) seals or reopens an inlet when a trapped air volume is heated or cooled, respectively. The RTPV is a gas-impermeable valve composed of an air chamber enclosed by a latex membrane and a specially designed liquid transition chamber that enables the efficient usage of the applied thermal energy. Inputting thermo-pneumatic (TP) energy into the air chamber deflects the membrane into the liquid transition chamber against an inlet, sealing it and thus preventing fluid flow. From this point, a centrifugal pressure higher than the induced TP pressure in the air chamber reopens the fluid pathway. The behaviour of this newly introduced reversible valving system on a microfluidic disk is studied experimentally and theoretically over a range of rotational frequencies from 700 RPM to 2500 RPM. Furthermore, adding a physical component (e.g., a hemispherical rubber element) to induce initial flow resistance shifts the operational range of rotational frequencies of the RTPV to more than 6000 RPM. An analytical solution for the cooling of a heated RTPV on a spinning disk is also presented, which highlights the need for the future development of time-programmable RTPVs. Moreover, the reversibility and gas impermeability of the RTPV in the

  6. Pneumatic artificial muscle actuators for compliant robotic manipulators

    NASA Astrophysics Data System (ADS)

    Robinson, Ryan Michael

    Robotic systems are increasingly being utilized in applications that require interaction with humans. In order to enable safe physical human-robot interaction, light weight and compliant manipulation are desirable. These requirements are problematic for many conventional actuation systems, which are often heavy, and typically use high stiffness to achieve high performance, leading to large impact forces upon collision. However, pneumatic artificial muscles (PAMs) are actuators that can satisfy these safety requirements while offering power-to-weight ratios comparable to those of conventional actuators. PAMs are extremely lightweight actuators that produce force in response to pressurization. These muscles demonstrate natural compliance, but have a nonlinear force-contraction profile that complicates modeling and control. This body of research presents solutions to the challenges associated with the implementation of PAMs as actuators in robotic manipulators, particularly with regard to modeling, design, and control. An existing PAM force balance model was modified to incorporate elliptic end geometry and a hyper-elastic constitutive relationship, dramatically improving predictions of PAM behavior at high contraction. Utilizing this improved model, two proof-of-concept PAM-driven manipulators were designed and constructed; design features included parallel placement of actuators and a tendon-link joint design. Genetic algorithm search heuristics were employed to determine an optimal joint geometry; allowing a manipulator to achieve a desired torque profile while minimizing the required PAM pressure. Performance of the manipulators was evaluated in both simulation and experiment employing various linear and nonlinear control strategies. These included output feedback techniques, such as proportional-integral-derivative (PID) and fuzzy logic, a model-based control for computed torque, and more advanced controllers, such as sliding mode, adaptive sliding mode, and

  7. Late effects from particulate radiations in primate and rabbit tissues

    NASA Technical Reports Server (NTRS)

    Lett, J. T.; Cox, A. B.; Bergtold, D. S.; Lee, A. C.; Pickering, J. E.

    1984-01-01

    In connection with studies regarding the hazards posed by ionizing radiations to man in space, the U.S. Air Force conducted an experiment about 20 years ago. In this experiment a large number of young rhesus monkeys was exposed to proton fluxes similar to those to be anticipated during solar flares. After irradiation, the animals were kept at the USAF School of Aerospace Medicine in Texas. The monkeys have been employed in investigations concerning aspects of late radiation damage. These investigations are discussed, taking into account the propagation of fibroblasts from irradiated monkeys. The results of the investigations are evaluated, giving attention also to experiments with white rabbits. It is found that, except in the case of major solar flares, when acute radiation damage could lead quickly to death, the hazards to astronauts from space radiations arise from such debilitating late effects as cataracts, damage to the central nervous system and benign tumors, and life-threatening neoplasia.

  8. Rod-based Fabrication of Customizable Soft Robotic Pneumatic Gripper Devices for Delicate Tissue Manipulation.

    PubMed

    Low, Jin-Huat; Yeow, Chen-Hua

    2016-01-01

    Soft compliant gripping is essential in delicate surgical manipulation for minimizing the risk of tissue grip damage caused by high stress concentrations at the point of contact. It can be achieved by complementing traditional rigid grippers with soft robotic pneumatic gripper devices. This manuscript describes a rod-based approach that combined both 3D-printing and a modified soft lithography technique to fabricate the soft pneumatic gripper. In brief, the pneumatic featureless mold with chamber component is 3D-printed and the rods were used to create the pneumatic channels that connect to the chamber. This protocol eliminates the risk of channels occluding during the sealing process and the need for external air source or related control circuit. The soft gripper consists of a chamber filled with air, and one or more gripper arms with a pneumatic channel in each arm connected to the chamber. The pneumatic channel is positioned close to the outer wall to create different stiffness in the gripper arm. Upon compression of the chamber which generates pressure on the pneumatic channel, the gripper arm will bend inward to form a close grip posture because the outer wall area is more compliant. The soft gripper can be inserted into a 3D-printed handling tool with two different control modes for chamber compression: manual gripper mode with a movable piston, and robotic gripper mode with a linear actuator. The double-arm gripper with two actuatable arms was able to pick up objects of sizes up to 2 mm and yet generate lower compressive forces as compared to elastomer-coated and non-coated rigid grippers. The feasibility of having other designs, such as single-arm or hook gripper, was also demonstrated, which further highlighted the customizability of the soft gripper device, and it's potential to be used in delicate surgical manipulation to reduce the risk of tissue grip damage. PMID:27584722

  9. Precision pneumatic pressure measurement with diaphragm-based mechatronic devices

    NASA Astrophysics Data System (ADS)

    Karuppanan, Balasubramanian; Akin, Cellatoglu

    2010-01-01

    A clamped circular metallic diaphragm, with shallow spherical shell deformation, elongates spherically proportional to the pressure acting on it. By making use of the inflation characteristics and mechanical properties of the diaphragm, three types of pneumatic pressure sensor are proposed in this article. In the first type, an optical mirror is engraved on its outer surface in an optimal position falling midway between its vertex and circumference. A laser beam is made to incident on the mirror and it gets deflected to fall over a matrix of photocells; the excitation of a particular cell in the coordinates of the matrix determines the pressure acting on the diaphragm. In the second proposal, a weightless secondary coil of a transformer is fixed around the vertex of the diaphragm which would move around a stationary magnetic core. The excitation of the primary coil wound over the magnetic core causes a voltage to be picked up in the secondary coil which would depend upon the displacement of the vertex because of pressure. The third type of the transducer is a capacitance pickup arrangement wherein the pressure is converted into capacitance and it is sensed and displayed as pressure. Furthermore, as an extension of the work, the motion of the diaphragm is mechanically coupled to a stylus for producing hard copy of the pressure over a strip chart.

  10. Variable recruitment in bundles of miniature pneumatic artificial muscles.

    PubMed

    DeLaHunt, Sylvie A; Pillsbury, Thomas E; Wereley, Norman M

    2016-01-01

    The natural compliance and force generation properties of pneumatic artificial muscles (PAMs) allow them to operate like human muscles in anthropomorphic robotic manipulators. Traditionally, manipulators use a single PAM or multiple PAMs actuated in unison in place of a human muscle. However, these standard manipulators can experience significant efficiency losses when operated outside their target performance ranges at low actuation pressures. This study considers the application of a variable recruitment control strategy to a parallel bundle of miniature PAMs as an attempt to mimic the selective recruitment of motor units in a human muscle. Bundles of miniature PAMs are experimentally characterized, their actuation behavior is modeled, and the efficiency gains and losses associated with the application of a variable recruitment control strategy are assessed. This bio-inspired control strategy allows muscle bundles to operate the fewest miniature PAMs necessary to achieve a desired performance objective, improving the muscle bundle's operating efficiency over larger ranges of force generation and displacement. The study also highlights the need for improved PAM fabrication techniques to facilitate the production of identical miniature PAMs for inclusion in muscle bundles. PMID:27623216

  11. Pneumatically-actuated artificial cilia array for biomimetic fluid propulsion.

    PubMed

    Gorissen, Benjamin; de Volder, Michaël; Reynaerts, Dominiek

    2015-11-21

    Arrays of beating cilia emerged in nature as one of the most efficient propulsion mechanisms at a small scale, and are omnipresent in microorganisms. Previous attempts at mimicking these systems have foundered against the complexity of fabricating small-scale cilia exhibiting complex beating motions. In this paper, we propose for the first time arrays of pneumatically-actuated artificial cilia that are able to address some of these issues. These artificial cilia arrays consist of six highly flexible silicone rubber actuators with a diameter of 1 mm and a length of 8 mm that can be actuated independently from each other. In an experimental setup, the effects of the driving frequency, phase difference and duty cycle on the net flow in a closed-loop channel have been studied. Net fluid speeds of up to 19 mm s(-1) have been measured. Further, it is possible to invert the flow direction by simply changing the driving frequency or by changing the duty cycle of the driving block pulse pressure wave without changing the bending direction of the cilia. Using PIV measurements, we corroborate for the first time existing mathematical models of cilia arrays to measurements on prototypes.

  12. Effectiveness of pneumatic reduction of ileocolic intussusception in children.

    PubMed

    Menor, F; Cortina, H; Marco, A; Olague, R

    1992-01-01

    A total of 158 consecutive therapeutic air enemas were performed upon 133 patients during a 2-year period. Perforation and/or an impairment of the general condition of the children were the only main contraindications for the reduction attempt (five patients). Successful reductions were achieved in 89% of cases with no complications. Operation was performed in all 17 cases of unsuccessful reduction: resection in four cases, easy manual reduction in nine, difficult manual reduction in two, and spontaneous reduction in two. There were 16 (12%) patients with one or more recurrent episodes. In 23 (16%) cases, following pneumatic reduction, a swollen ileocecal valve showing a multiple appearance was observed. This fact sometimes results in a differential diagnosis with incomplete reduction; in all these cases, small bowel aeration was always a sign of complete reduction. No significant difference was noted between a swollen ileocecal valve and patient age, duration of symptoms, presence of small bowel obstruction, and further recurrences. Air enema has improved our previous success obtained with hydrostatic reduction (79%), as well as being a simpler, cleaner, and faster technique for intussusception reduction in children. PMID:1426851

  13. MRI-Compatible Pneumatic Robot for Transperineal Prostate Needle Placement

    PubMed Central

    Fischer, Gregory S.; Iordachita, Iulian; Csoma, Csaba; Tokuda, Junichi; DiMaio, Simon P.; Tempany, Clare M.; Hata, Nobuhiko; Fichtinger, Gabor

    2010-01-01

    Magnetic resonance imaging (MRI) can provide high-quality 3-D visualization of prostate and surrounding tissue, thus granting potential to be a superior medical imaging modality for guiding and monitoring prostatic interventions. However, the benefits cannot be readily harnessed for interventional procedures due to difficulties that surround the use of high-field (1.5T or greater) MRI. The inability to use conventional mechatronics and the confined physical space makes it extremely challenging to access the patient. We have designed a robotic assistant system that overcomes these difficulties and promises safe and reliable intraprostatic needle placement inside closed high-field MRI scanners. MRI compatibility of the robot has been evaluated under 3T MRI using standard prostate imaging sequences and average SNR loss is limited to 5%. Needle alignment accuracy of the robot under servo pneumatic control is better than 0.94 mm rms per axis. The complete system workflow has been evaluated in phantom studies with accurate visualization and targeting of five out of five 1 cm targets. The paper explains the robot mechanism and controller design, the system integration, and presents results of preliminary evaluation of the system. PMID:21057608

  14. Characterisation of a phenomenological model for commercial pneumatic muscle actuators.

    PubMed

    Serres, J L; Reynolds, D B; Phillips, C A; Gerschutz, M J; Repperger, D W

    2009-08-01

    This study focuses on the parameter characterisation of a three-element phenomenological model for commercially available pneumatic muscle actuators (PMAs). This model consists of a spring, damping and contractile element arranged in parallel. Data collected from static loading, contraction and relaxation experiments were fitted to theoretical solutions of the governing equation for the three-element model resulting in prediction profiles for the spring, damping and contractile force coefficient. For the spring coefficient, K N/mm, the following relationships were found: K = 32.7 - 0.0321P for 150 < or = P < or = 314 kPa and K = 17 + 0.0179P for 314 < or = P < or = 550 kPa. For the damping coefficient, B Ns/mm, the following relationship was found during contraction: B = 2.90 for 150 < or = P < or = 550 kPa. During relaxation, B = 1.57 for 150 < or = P < or = 372 kPa and B = 0.311 + 0.00338P for 372 < or = P < or = 550. The following relationship for the contractile force coefficient, F(ce) N, was also determined: F(ce) = 2.91P+44.6 for 150 < or = P < or = 550 kPa. The model was then validated by reasonably predicting the response of the PMA to a triangular wave input in pressure under a constant load on a dynamic test station.

  15. Observations of ''granular jump'' in the pneumatic conveying system

    SciTech Connect

    Jaworski, Artur J.; Dyakowski, Tomasz

    2007-08-15

    This paper presents a preliminary study of a previously unreported phenomenon of the ''gas driven granular jump'', observed in the gas-solids flow within the pneumatic conveying system. From the phenomenological point of view, it resembles the already known processes such as hydraulic jumps in shallow water or granular jumps in granular flows in chutes or avalanches (although it seems most appropriate to explain it by analogy to a propagating granular bore). Clearly, unlike in classical phenomena of this type, the flow itself is driven by the aerodynamic forces related to the gas flow and the behaviour of the front of the ''jump'' is modified significantly by their presence. A series of high-speed camera visualisations are presented, which focus on this unusual behaviour of the flow on the border-line between cluster and stratified flow regimes in a horizontal pipe. Some similarities are drawn between the observed phenomenon and the broader class of problems exhibiting transition between super- and sub-critical flows. The fluid dynamical aspects and possible mechanisms behind the new phenomenon are discussed and the results obtained are compared quantitatively with simple theoretical models. (author)

  16. Pneumatically-actuated artificial cilia array for biomimetic fluid propulsion.

    PubMed

    Gorissen, Benjamin; de Volder, Michaël; Reynaerts, Dominiek

    2015-11-21

    Arrays of beating cilia emerged in nature as one of the most efficient propulsion mechanisms at a small scale, and are omnipresent in microorganisms. Previous attempts at mimicking these systems have foundered against the complexity of fabricating small-scale cilia exhibiting complex beating motions. In this paper, we propose for the first time arrays of pneumatically-actuated artificial cilia that are able to address some of these issues. These artificial cilia arrays consist of six highly flexible silicone rubber actuators with a diameter of 1 mm and a length of 8 mm that can be actuated independently from each other. In an experimental setup, the effects of the driving frequency, phase difference and duty cycle on the net flow in a closed-loop channel have been studied. Net fluid speeds of up to 19 mm s(-1) have been measured. Further, it is possible to invert the flow direction by simply changing the driving frequency or by changing the duty cycle of the driving block pulse pressure wave without changing the bending direction of the cilia. Using PIV measurements, we corroborate for the first time existing mathematical models of cilia arrays to measurements on prototypes. PMID:26439855

  17. An electromagnetic microvalve for pneumatic control of microfluidic systems.

    PubMed

    Liu, Xuling; Li, Songjing

    2014-10-01

    An electromagnetic microvalve for pneumatic control of microfluidic devices has been designed, fabricated, and tested. The microvalve is composed of two parts: a miniature electromagnetic actuator and a valve body. The electromagnetic actuator consists mainly of a thin polydimethylsiloxane (PDMS)-based elastomer, which acts as the valve diaphragm. The diaphragm, used as a solid hydraulic medium, converts the large contact area of a valve core into a small contact area of valve head while maintaining a large stroking force. This microvalve remains closed because of a compressed mechanical spring force generated by the actuator. On the other hand, when a voltage is applied, the valve core moves up, relaxing the thin PDMS membrane, opening the microvalve. The fast open response (~17 ms) of the valve was achieved with a leak rate as low as 0.026 sccm at 200 KPa (N2) pressure. We tested the pertinent dynamic parameters such as flow rate in on/off mode, flow rate of duty cycles, and actuated frequencies in pulse width modulation (PWM) mode. Our method provides a simple, cheap, and small microvalve that avoids the bulky and expensive external pressure control solenoid manifold. This allows it to be easily integrated into portable and disposable devices. PMID:24742860

  18. Controllable surface haptics via particle jamming and pneumatics.

    PubMed

    Stanley, Andrew A; Okamura, Allison M

    2015-01-01

    The combination of particle jamming and pneumatics allows the simultaneous control of shape and mechanical properties in a tactile display. A hollow silicone membrane is molded into an array of thin cells, each filled with coffee grounds such that adjusting the vacuum level in any individual cell rapidly switches it between flexible and rigid states. The array clamps over a pressure-regulated air chamber with internal mechanisms designed to pin the nodes between cells at any given height. Various sequences of cell vacuuming, node pinning, and chamber pressurization allow the surface to balloon into a variety of shapes. Experiments were performed to expand existing physical models of jamming at the inter-particle level to define the rheological characteristics of jammed systems from a macroscopic perspective, relevant to force-displacement interactions that would be experienced by human users. Force-displacement data show that a jammed cell in compression fits a Maxwell model and a cell deflected in the center while supported only at the edges fits a Zener model, each with stiffness and damping parameters that increase at higher levels of applied vacuum. This provides framework to tune and control the mechanical properties of a jamming haptic interface.

  19. An electromagnetic microvalve for pneumatic control of microfluidic systems.

    PubMed

    Liu, Xuling; Li, Songjing

    2014-10-01

    An electromagnetic microvalve for pneumatic control of microfluidic devices has been designed, fabricated, and tested. The microvalve is composed of two parts: a miniature electromagnetic actuator and a valve body. The electromagnetic actuator consists mainly of a thin polydimethylsiloxane (PDMS)-based elastomer, which acts as the valve diaphragm. The diaphragm, used as a solid hydraulic medium, converts the large contact area of a valve core into a small contact area of valve head while maintaining a large stroking force. This microvalve remains closed because of a compressed mechanical spring force generated by the actuator. On the other hand, when a voltage is applied, the valve core moves up, relaxing the thin PDMS membrane, opening the microvalve. The fast open response (~17 ms) of the valve was achieved with a leak rate as low as 0.026 sccm at 200 KPa (N2) pressure. We tested the pertinent dynamic parameters such as flow rate in on/off mode, flow rate of duty cycles, and actuated frequencies in pulse width modulation (PWM) mode. Our method provides a simple, cheap, and small microvalve that avoids the bulky and expensive external pressure control solenoid manifold. This allows it to be easily integrated into portable and disposable devices.

  20. Effectiveness of Thermal-Pneumatic Airfoil-Ice-Protection System

    NASA Technical Reports Server (NTRS)

    Gowan, William H., Jr.; Mulholland, Donald R.

    1951-01-01

    Icing and drag investigations were conducted in the NACA Lewis icing research tunnel employing a combination thermal-pneumatic de-icer mounted on a 42-inch-chord NACA 0018 airfoil. The de-icer consisted of a 3-inch-wide electrically heated strip symmetrically located about the leading edge with inflatable tubes on the upper and lower airfoil surfaces aft of the heated area. The entire de-icer extended to approximately 25 percent of chord. A maximum power density of 9.25 watts per square inch was required for marginal ice protection on the airfoil leading edge at an air temperature of 00 F and an airspeed of 300 miles per hour. Drag measurements indicated, that without icing, the de-icer installation increased the section drag to approximately 140 percent of that of the bare airfoil; with the tubes inflated, this value increased to a maximum of approximately 620 percent. A 2-minute tube-inflation cycle prevented excessive ice formation on the inflatable area although small scattered residual Ice formations remained after inflation and were removed intermittently during later cycles. Effects of the time lag of heater temperatures after initial application of power and the insulating effect of ice formations on heater temperatures were also determined.

  1. MRI-Compatible Pneumatic Robot for Transperineal Prostate Needle Placement.

    PubMed

    Fischer, Gregory S; Iordachita, Iulian; Csoma, Csaba; Tokuda, Junichi; Dimaio, Simon P; Tempany, Clare M; Hata, Nobuhiko; Fichtinger, Gabor

    2008-06-01

    Magnetic resonance imaging (MRI) can provide high-quality 3-D visualization of prostate and surrounding tissue, thus granting potential to be a superior medical imaging modality for guiding and monitoring prostatic interventions. However, the benefits cannot be readily harnessed for interventional procedures due to difficulties that surround the use of high-field (1.5T or greater) MRI. The inability to use conventional mechatronics and the confined physical space makes it extremely challenging to access the patient. We have designed a robotic assistant system that overcomes these difficulties and promises safe and reliable intraprostatic needle placement inside closed high-field MRI scanners. MRI compatibility of the robot has been evaluated under 3T MRI using standard prostate imaging sequences and average SNR loss is limited to 5%. Needle alignment accuracy of the robot under servo pneumatic control is better than 0.94 mm rms per axis. The complete system workflow has been evaluated in phantom studies with accurate visualization and targeting of five out of five 1 cm targets. The paper explains the robot mechanism and controller design, the system integration, and presents results of preliminary evaluation of the system.

  2. A pneumatically-actuated lower-limb orthosis.

    PubMed

    Wu, Sai-Kit; Jordan, Matthew; Shen, Xiangrong

    2011-01-01

    Powered lower-limb orthosis is a type of wearable mechanical devices that can serve a wide variety of important biomedical purposes. Due to the constraints associated with the actuation technology, the majority of current lower-limb orthoses are either passive or tethered to external power sources, limiting the functionality of such devices. In this paper, the authors present their preliminary research results towards a fully mobile (i.e. untethered) powered lower-limb orthosis, leveraging the high power density of pneumatic actuators for the joint power generation. The design of the orthosis is presented, with the objectives of providing full assistance in the locomotion of various common locomotive modes, and generating minimum level of restriction to the wearer's daily activities. To regulate the power delivery on the joints for a natural gait assistance, a finite-state impedance controller is developed, which simulates an artificial impedance to enable an effective interaction with the wearer. Preliminary testing demonstrated that the orthosis was able to provide a natural gait and comfortable user experience in the treadmill walking experiments.

  3. 9 CFR 354.124 - Quarantine of diseased rabbits.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... Procedures; Ante-Mortem Inspections § 354.124 Quarantine of diseased rabbits. If live rabbits, which are... further handling of the rabbits will not create a health hazard, the lot shall be subject to ante-mortem... circumstances are such that release for treatment is impracticable, a careful rabbit-by-rabbit...

  4. Effects of X radiation on the retina of the albino rabbit as viewed with the scanning electron microscope

    SciTech Connect

    Newton, J.C.; Barsa-Newton, M.C.; Wardly, J.

    1980-02-01

    The eyes of albino rabbits were exposed in vivo to 7000 rad of X radiation, and the retinas were examined with a scanning electron microscope 24 and 72 h after irradiation. The rods and cones of the retina were observed to show the most severe damage.

  5. Late effects from particulate radiations in primate and rabbit tissues

    NASA Astrophysics Data System (ADS)

    Lett, J. T.; Cox, A. B.; Bergtold, D. S.; Lee, A. C.; Pickering, J. E.

    Optic tissues in groups of New Zealand white rabbits were irradiated locally at different stages throughout the median life span of the species with a single dose (9 Gy) of 425 MeV/amu Ne ions (LET∞~30 keV/μm) and then inspected routinely for the progression of radiation cataracts. The level of early cataracts was found to be highest in the youngest group of animals irradiated (8 weeks old) but both the onset of late cataracts and loss of vision occurred earlier when animals were irradiated during the second half of the median life span. This age response can have serious implications in terms of space radiation hazards to man. Rhesus monkeys that had been subjected to whole-body skin irradiation (2.8 and 5.6 Gy) by 32 MeV protons (range in tissue ~ 1 cm) some twenty years previously were analysed for radiation damage by the propagation of skin fibroblasts in primary cultures. Such propagation from skin biopsies in MEM-α medium (serial cultivation) or in supplemented Ham's F-10 medium (cultivation without dilution) revealed late damage in the stem (precursor) cells of the skins of the animals. The proton fluxes employed in this experiment are representative of those occurring in major solar flares.

  6. Variable modulus cellular structures using pneumatic artificial muscles

    NASA Astrophysics Data System (ADS)

    Pontecorvo, Michael E.; Niemiec, Robert J.; Gandhi, Farhan S.

    2014-04-01

    This paper presents a novel variable modulus cellular structure based on a hexagonal unit cell with pneumatic artificial muscle (PAM) inclusions. The cell considered is pin-jointed, loaded in the horizontal direction, with three PAMs (one vertical PAM and two horizontal PAMs) oriented in an "H" configuration between the vertices of the cell. A method for calculation of the hexagonal cell modulus is introduced, as is an expression for the balance of tensile forces between the horizontal and vertical PAMs. An aluminum hexagonal unit cell is fabricated and simulation of the hexagonal cell with PAM inclusions is then compared to experimental measurement of the unit cell modulus in the horizontal direction with all three muscles pressurized to the same value over a pressure range up to 758 kPa. A change in cell modulus by a factor of 1.33 and a corresponding change in cell angle of 0.41° are demonstrated experimentally. A design study via simulation predicts that differential pressurization of the PAMs up to 2068 kPa can change the cell modulus in the horizontal direction by a factor of 6.83 with a change in cell angle of only 2.75°. Both experiment and simulation show that this concept provides a way to decouple the length change of a PAM from the change in modulus to create a structural unit cell whose in-plane modulus in a given direction can be tuned based on the orientation of PAMs within the cell and the pressure supplied to the individual muscles.

  7. Single line reversing system capsular pneumatic freight pipelines

    SciTech Connect

    Weaver, P.B.

    1999-07-01

    In the 1800's the first Pneumatic Tube Systems sent a carrier vertically from one floor to another in a hospital using a foot-powered bellows. The carrier was returned to the starting point down the same tube using gravity. This was the first Single Line Reversing system. As the stations were moved apart horizontally the foot-powered bellows at both ends became ineffective and were replaced with a single blower or exhauster. The blower/exhauster ran continuously therefore a second line for returning carriers to the starting point, had to be installed - hence Twin Line systems. These systems were used for transporting mail, paperwork, medications, steel mill samples, parts, tools, medical lab samples, etc., in hospitals, stores and other businesses. Twin Line systems were very popular until about 1970 at which time installation labor and material costs became expensive and controls were becoming unnecessarily complicated and expensive. These reasons plus new technology forced the return to Single Line Reversing technology. Back in the 1800's three ``people transporting'' subways were built. A fourth system was built under the Pentagon in the 1950's or 1960's. It is difficult to find information on this one. All are Single Line Reversing systems. The difference between a Single Line Reversing and a Twin Line system is exactly as the names imply. The principle of the operation of these systems is covered herein. The physics for these two kinds of systems is the same. The Single Line Reversing system is technically more complex but capital and operating expense is far less costly. These costs are discussed herein.

  8. Radiation Damage Study in Natural Zircon Using Neutrons Irradiation

    SciTech Connect

    Lwin, Maung Tin Moe; Amin, Yusoff Mohd.; Kassim, Hasan Abu; Mohamed, Abdul Aziz; Karim, Julia Abdul

    2011-03-30

    Changes of atomic displacements in crystalline structure of natural zircon (ZrSiO{sub 4}) can be studied by using neutron irradiation on the surface of zircon and compared the data from XRD measurements before and after irradiation. The results of neutron irradiation on natural zircon using Pneumatic Transfer System (PTS) at PUSPATI TRIGA Research Reactor in the Malaysian Nuclear Agency are discussed in this work. The reactor produces maximum thermal power output of 1 MWatt and the neutron flux of up to 1x10{sup 13} ncm{sup -2}s{sup -1}. From serial decay processes of uranium and thorium radionuclides in zircon crystalline structure, the emission of alpha particles can produce damage in terms of atomic displacements in zircon. Hence, zircon has been extensively studied as a possible candidate for immobilization of fission products and actinides.

  9. Immunosuppression abrogates resistance of young rabbits to Rabbit Haemorrhagic Disease (RHD)

    PubMed Central

    2014-01-01

    Rabbit Haemorrhagic Disease (RHD) is caused by a calicivirus (RHDV) that kills 90% of infected adult European rabbits within 3 days. Remarkably, young rabbits are resistant to RHD. We induced immunosuppression in young rabbits by treatment with methylprednisolone acetate (MPA) and challenged the animals with RHDV by intramuscular injection. All of these young rabbits died within 3 days of infection due to fulminant hepatitis, presenting a large number of RHDV-positive dead or apoptotic hepatocytes, and a significant seric increase in cytokines, features that are similar to those of naïve adult rabbits infected by RHDV. We conclude that MPA-induced immunosuppression abrogates the resistance of young rabbits to RHD, indicating that there are differences in the innate immune system between young and adult rabbits that contribute to their distinct resistance/susceptibility to RHDV infection. PMID:24490832

  10. Immunosuppression abrogates resistance of young rabbits to Rabbit Haemorrhagic Disease (RHD).

    PubMed

    Marques, Raquel M; Teixeira, Luzia; Aguas, Artur P; Ribeiro, Joana C; Costa-e-Silva, António; Ferreira, Paula G

    2014-02-04

    Rabbit Haemorrhagic Disease (RHD) is caused by a calicivirus (RHDV) that kills 90% of infected adult European rabbits within 3 days. Remarkably, young rabbits are resistant to RHD. We induced immunosuppression in young rabbits by treatment with methylprednisolone acetate (MPA) and challenged the animals with RHDV by intramuscular injection. All of these young rabbits died within 3 days of infection due to fulminant hepatitis, presenting a large number of RHDV-positive dead or apoptotic hepatocytes, and a significant seric increase in cytokines, features that are similar to those of naïve adult rabbits infected by RHDV. We conclude that MPA-induced immunosuppression abrogates the resistance of young rabbits to RHD, indicating that there are differences in the innate immune system between young and adult rabbits that contribute to their distinct resistance/susceptibility to RHDV infection.

  11. 49 CFR 236.565 - Provision made for preventing operation of pneumatic brake-applying apparatus by double-heading...

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Provision made for preventing operation of pneumatic brake-applying apparatus by double-heading cock; requirement. 236.565 Section 236.565... preventing operation of pneumatic brake-applying apparatus by double-heading cock; requirement....

  12. 49 CFR 236.565 - Provision made for preventing operation of pneumatic brake-applying apparatus by double-heading...

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 4 2011-10-01 2011-10-01 false Provision made for preventing operation of pneumatic brake-applying apparatus by double-heading cock; requirement. 236.565 Section 236.565... preventing operation of pneumatic brake-applying apparatus by double-heading cock; requirement....

  13. Vibration control of a pneumatic driven piezoelectric flexible manipulator using self-organizing map based multiple models

    NASA Astrophysics Data System (ADS)

    Zhao, Zhi-li; Qiu, Zhi-cheng; Zhang, Xian-min; Han, Jian-da

    2016-03-01

    A kind of hybrid pneumatic-piezoelectric flexible manipulator system has been presented in the paper. A hybrid driving scheme is achieved by combining of a pneumatic proportional valve based pneumatic drive and a piezoelectric actuator bonded to the flexible beam. The system dynamics models are obtained based on system identification approaches, using the established experimental system. For system identification of the flexible piezoelectric manipulator subsystem, parametric estimation methods are utilized. For the pneumatic driven system, a single global linear model is not accurate enough to describe its dynamics, due to the high nonlinearity of the pneumatic driven system. Therefore, a self-organizing map (SOM) based multi-model system identification approach is used to get multiple local linear models. Then, a SOM based multi-model inverse controller and a variable damping pole-placement controller are applied to the pneumatic drive and piezoelectric actuator, respectively. Experiments on pneumatic driven vibration control, piezoelectric vibration control and hybrid vibration control are conducted, utilized proportional and derivative (PD) control, SOM based multi-model inverse controller, and the variable damping pole-placement controller. Experimental results demonstrate that the investigated control algorithms can improve the vibration control performance of the pneumatic driven flexible piezoelectric manipulator system.

  14. 75 FR 28567 - New Pneumatic Off-the-Road Tires From the People's Republic of China: Notice of Partial...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-05-21

    ... International Trade Administration New Pneumatic Off-the-Road Tires From the People's Republic of China: Notice... antidumping duty order on New Pneumatic Off-the-Road Tires (``OTR tires'') from the People's Republic of China... Administrative Review, 74 FR 45179 (September 1, 2009). On September 28, 2009, Guizhou Tire I&E...

  15. 75 FR 32159 - Certain New Pneumatic Off-the-Road Tires from the People's Republic of China: Extension of Time...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-06-07

    ... International Trade Administration Certain New Pneumatic Off-the-Road Tires from the People's Republic of China... new pneumatic off-the-road tires from the People's Republic of China for the period December 17, 2007... and Requests for Revocation in Part, 74 FR 54956 (October 26, 2009). This review covers one...

  16. 77 FR 10476 - Certain New Pneumatic Off-the-Road Tires From the People's Republic of China: Notice of Second...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-02-22

    ... International Trade Administration Certain New Pneumatic Off-the-Road Tires From the People's Republic of China... the administrative review of the antidumping duty order on certain new pneumatic off-the-road tires (``off-the-road tires'') from the People's Republic of China (``PRC'') for the period, September 1,...

  17. 75 FR 74003 - Certain New Pneumatic Off-the-Road Tires From the People's Republic of China: Partial Rescission...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-11-30

    ... International Trade Administration Certain New Pneumatic Off-the-Road Tires From the People's Republic of China... pneumatic off-the-road tires (OTR Tires) from the People's Republic of China (PRC) for the period January 1... Investigation; Opportunity To Request Administrative Review, 75 FR 53635 (September 1, 2010). Guizhou...

  18. 76 FR 14919 - Certain New Pneumatic Off-the-Road Tires From the People's Republic of China: Notice of Partial...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-03-18

    ... International Trade Administration Certain New Pneumatic Off-the-Road Tires From the People's Republic of China... administrative review of the antidumping duty order on certain new pneumatic off-the-road tires (``OTR tires...; Opportunity to Request Administrative Review, 75 FR 53635 (September 1, 2010). On September 17, 2010,...

  19. 75 FR 846 - Certain New Pneumatic Off-the-Road Tires From the People's Republic of China: Partial Rescission...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-01-06

    ... International Trade Administration Certain New Pneumatic Off-the-Road Tires From the People's Republic of China... Pneumatic Off-the-Road Tires (OTR Tires) from the People's Republic of China (PRC) for the period December... Administrative Review, 74 FR 45179 (September 1, 2009). GPX timely requested an administrative review of...

  20. 75 FR 32158 - New Pneumatic Off-the-Road Tires from the People's Republic of China: Extension of Preliminary...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-06-07

    ... International Trade Administration New Pneumatic Off-the-Road Tires from the People's Republic of China... pneumatic off-the-road tires (``OTR Tires'') from the People's Republic of China (``PRC''). This review... Revocation in Part, 74 FR 54956 (October 26, 2009). The preliminary results of this review are currently...

  1. 76 FR 7816 - Certain New Pneumatic Off-the-Road Tires From the People's Republic of China: Rescission of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-02-11

    ... International Trade Administration Certain New Pneumatic Off-the-Road Tires From the People's Republic of China... administrative review of the countervailing duty order on certain new pneumatic off-the-road tires (OTR Tires... Off-the-Road Tires From the People's Republic of China: Partial Rescission of Countervailing...

  2. 49 CFR 236.565 - Provision made for preventing operation of pneumatic brake-applying apparatus by double-heading...

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... pneumatic brake-applying apparatus by double-heading cock; requirement. 236.565 Section 236.565... preventing operation of pneumatic brake-applying apparatus by double-heading cock; requirement. Where... train stop or train control device when the double-heading cock is placed in double-heading...

  3. 49 CFR 236.565 - Provision made for preventing operation of pneumatic brake-applying apparatus by double-heading...

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... pneumatic brake-applying apparatus by double-heading cock; requirement. 236.565 Section 236.565... preventing operation of pneumatic brake-applying apparatus by double-heading cock; requirement. Where... train stop or train control device when the double-heading cock is placed in double-heading...

  4. 49 CFR 236.565 - Provision made for preventing operation of pneumatic brake-applying apparatus by double-heading...

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... pneumatic brake-applying apparatus by double-heading cock; requirement. 236.565 Section 236.565... preventing operation of pneumatic brake-applying apparatus by double-heading cock; requirement. Where... train stop or train control device when the double-heading cock is placed in double-heading...

  5. Heller's cardiomyotomy compared with pneumatic dilatation for treatment of oesophageal achalasia.

    PubMed

    Mäkelä, J; Kiviniemi, H; Laitinen, S

    1991-01-01

    The records of 30 patients treated for oesophageal achalasia between 1976 and 1988 were analysed retrospectively. Early and late results were collected to compare the safety and efficacy of Heller's myotomy (n = 13) and pneumatic dilatation (n = 17). Unsatisfactory immediate postoperative results were found in 4 of 13 of the patients who had undergone myotomy (31%) and in 4 of the 17 patients treated by pneumatic dilatation (24%). More patients had improved swallowing during the first postoperative year after myotomy, but this difference ceased with time. The severity of the symptoms affected the results, and dilatations that had to be repeated more than twice were ineffective. We conclude that pneumatic dilatation is as safe as Heller's myotomy, and that although the early results are significantly better after myotomy, the late results are similar.

  6. Controllable pneumatic generator based on the catalytic decomposition of hydrogen peroxide

    SciTech Connect

    Kim, Kyung-Rok; Kim, Kyung-Soo Kim, Soohyun

    2014-07-15

    This paper presents a novel compact and controllable pneumatic generator that uses hydrogen peroxide decomposition. A fuel micro-injector using a piston-pump mechanism is devised and tested to control the chemical decomposition rate. By controlling the injection rate, the feedback controller maintains the pressure of the gas reservoir at a desired pressure level. Thermodynamic analysis and experiments are performed to demonstrate the feasibility of the proposed pneumatic generator. Using a prototype of the pneumatic generator, it takes 6 s to reach 3.5 bars with a reservoir volume of 200 ml at the room temperature, which is sufficiently rapid and effective to maintain the repetitive lifting of a 1 kg mass.

  7. Torque characteristics of a 122-centimeter butterfly valve with a hydro/pneumatic actuator

    NASA Technical Reports Server (NTRS)

    Lin, F. N.; Moore, W. I.; Lundy, F. E.

    1981-01-01

    Actuating torque data from field testing of a 122-centimeter (48 in.) butterfly valve with a hydro/pneumatic actuator is presented. The hydraulic cylinder functions as either a forward or a reverse brake. Its resistance torque increases when the valve speeds up and decreases when the valve slows down. A reduction of flow resistance in the hydraulic flow path from one end of the hydraulic cylinder to the other will effectively reduce the hydraulic resistance torque and hence increase the actuating torque. The sum of hydrodynamic and friction torques (combined resistance torque) of a butterfly valve is a function of valve opening time. An increase in the pneumatic actuating pressure will result in a decrease in both the combined resistance torque and the actuator opening torque; however, it does shorten the valve opening time. As the pneumatic pressure increases, the valve opening time for a given configuration approaches an asymptotical value.

  8. Automated system for removal and pneumatic transport of fly ash from electric precipitator hoppers

    SciTech Connect

    V.K. Konovalov; O.V. Yashkin; V.V. Ermakov

    2008-03-15

    A system for removal and pneumatic transport of fly ash is examined, in which air pulses act on batches (pistons) of ash formed in a duct. Studies are made of the effect of several physical parameters on the force required to displace a piston of ash and these serve as a basis for choosing a system for removal and pneumatic transport of ash simultaneously from several hoppers of an electric precipitator. This makes it possible to separate the ash particles according to size without introducing additional components. Formulas are given for calculating the structural and dynamic parameters of this system and measurements of indirect dynamic parameters are used to calculate the input-output characteristics of the system. In order to optimize the system, configurations for summing several ducts into a single transport duct for pneumatic ash transport are proposed. Some variants of dry ash utilization and the advantages of producing of size-separated particles are considered.

  9. A magnetorheological fluid embedded pneumatic vibration isolator allowing independently adjustable stiffness and damping

    NASA Astrophysics Data System (ADS)

    Zhu, Xiaocong; Jing, Xingjian; Cheng, Li

    2011-08-01

    A magnetorheological (MR) fluid embedded pneumatic vibration isolator (MrEPI) with hybrid and compact connection of pneumatic spring and MR damping elements is proposed in this study. The proposed MrEPI system allows independent nonlinear stiffness and damping control with considerable maneuverable ranges. Meanwhile, it allows convenient switching between different passive and active vibration control modes, thus providing more flexibility and versatility in applications. To demonstrate the advantageous dynamic performance of the MrEPI, a nonlinear non-dimensional dynamic model is developed with full consideration of the nonlinear elements involved. A systematic analysis is therefore conducted which can clearly reveal the influence on system output performance caused by each physically important parameter and provide a useful insight into the analysis and design of nonlinear vibration isolators with pneumatic and MR elements.

  10. Controllable pneumatic generator based on the catalytic decomposition of hydrogen peroxide.

    PubMed

    Kim, Kyung-Rok; Kim, Kyung-Soo; Kim, Soohyun

    2014-07-01

    This paper presents a novel compact and controllable pneumatic generator that uses hydrogen peroxide decomposition. A fuel micro-injector using a piston-pump mechanism is devised and tested to control the chemical decomposition rate. By controlling the injection rate, the feedback controller maintains the pressure of the gas reservoir at a desired pressure level. Thermodynamic analysis and experiments are performed to demonstrate the feasibility of the proposed pneumatic generator. Using a prototype of the pneumatic generator, it takes 6 s to reach 3.5 bars with a reservoir volume of 200 ml at the room temperature, which is sufficiently rapid and effective to maintain the repetitive lifting of a 1 kg mass.

  11. 76 FR 4287 - New Pneumatic Off-the-Road Tires From the People's Republic of China: Extension of Time Limit for...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-01-25

    ... International Trade Administration New Pneumatic Off-the-Road Tires From the People's Republic of China... pneumatic off-the-road tires from the People's Republic of China. See New Pneumatic Off-the-Road Tires From... FR 64268 (October 19, 2010) (Preliminary Results). This administrative review covers the...

  12. Enema reduction of intussusception: the success rate of hydrostatic and pneumatic reduction

    PubMed Central

    Khorana, Jiraporn; Singhavejsakul, Jesda; Ukarapol, Nuthapong; Laohapensang, Mongkol; Wakhanrittee, Junsujee; Patumanond, Jayanton

    2015-01-01

    Purpose Intussusception is a common surgical emergency in infants and children. The incidence of intussusception is from one to four per 2,000 infants and children. If there is no peritonitis, perforation sign on abdominal radiographic studies, and nonresponsive shock, nonoperative reduction by pneumatic or hydrostatic enema can be performed. The purpose of this study was to compare the success rates of both the methods. Methods Two institutional retrospective cohort studies were performed. All intussusception patients (ICD-10 code K56.1) who had visited Chiang Mai University Hospital and Siriraj Hospital from January 2006 to December 2012 were included in the study. The data were obtained by chart reviews and electronic databases, which included demographic data, symptoms, signs, and investigations. The patients were grouped according to the method of reduction followed into pneumatic reduction and hydrostatic reduction groups with the outcome being the success of the reduction technique. Results One hundred and seventy episodes of intussusception occurring in the patients of Chiang Mai University Hospital and Siriraj Hospital were included in this study. The success rate of pneumatic reduction was 61% and that of hydrostatic reduction was 44% (P=0.036). Multivariable analysis and adjusting of the factors by propensity scores were performed; the success rate of pneumatic reduction was 1.48 times more than that of hydrostatic reduction (P=0.036, 95% confidence interval [CI] =1.03–2.13). Conclusion Both pneumatic and hydrostatic reduction can be performed safely according to the experience of the radiologist or pediatric surgeon and hospital setting. This study showed that pneumatic reduction had a higher success rate than hydrostatic reduction. PMID:26719697

  13. Postcranial pneumaticity and bone structure in two clades of neognath birds.

    PubMed

    Gutzwiller, Sarah C; Su, Anne; O'Connor, Patrick M

    2013-06-01

    Most living birds exhibit some degree of postcranial skeletal pneumaticity, aeration of the postcranial skeleton by pulmonary air sacs and/or directly from the lungs. The extent of pneumaticity varies greatly, ranging from taxa that are completely apneumatic to those with air filling most of the postcranial skeleton. This study examined the influence of skeletal pneumatization on bone structural parameters in a sample of two size- and foraging-style diverse (e.g., subsurface diving vs. soaring specialists) clades of neognath birds (charadriiforms and pelecaniforms). Cortical bone thickness and trabecular bone volume fraction were assessed in one cervical and one thoracic vertebra in each of three pelecaniform and four charadriiform species. Results for pelecaniforms indicate that specialized subsurface dive foragers (e.g., the apneumatic anhinga) have thicker cortical bone and a higher trabecular bone volume fraction than their non-diving clademates. Conversely, the large-bodied, extremely pneumatic brown pelican (Pelecanus occidentalis) exhibits thinner cortical bone and a lower trabecular bone volume fraction. Such patterns in bone structural parameters are here interpreted to pertain to decreased buoyancy in birds specialized in subsurface dive foraging and decreased skeletal density (at the whole bone level) in birds of larger body size. The potential to differentially pneumatize the postcranial skeleton and alter bone structure may have played a role in relaxing constraints on body size evolution and/or habitat exploitation during the course of avian evolution. Notably, similar patterns were not observed within the equally diverse charadriiforms, suggesting that the relationship between pneumaticity and bone structure is variable among different clades of neognath birds.

  14. Design and Control of a 1-DOF MRI Compatible Pneumatically Actuated Robot with Long Transmission Lines

    PubMed Central

    Yang, Bo; Tan, U-Xuan; McMillan, Alan; Gullapalli, Rao; Desai, Jaydev P.

    2011-01-01

    This paper presents the design and control of an MRI-compatible 1-DOF needle driver robot and its precise position control using pneumatic actuation with long transmission lines. MRI provides superior image quality compared to other imaging modalities such as CT or ultrasound, but imposes severe limitations on the material and actuator choice (to prevent image distortion) due to its strong magnetic field. We are primarily interested in developing a pneumatically actuated breast biopsy robot with a large force bandwidth and precise targeting capability during radio-frequency ablation (RFA) of breast tumor, and exploring the possibility of using long pneumatic transmission lines from outside the MRI room to the device in the magnet to prevent any image distortion whatsoever. This paper presents a model of the entire pneumatic system. The pneumatic lines are approximated by a first order system with time delay, because its dynamics are governed by the telegraph equation with varying coefficients and boundary conditions, which cannot be solved precisely. The slow response of long pneumatic lines and valve subsystems make position control challenging. This is further compounded by the presence of non-uniform friction in the device. Sliding mode control (SMC) was adopted, where friction was treated as an uncertainty term to drive the system onto the sliding surface. Three different controllers were designed, developed, and evaluated to achieve precise position control of the RFA probe. Experimental results revealed that all SMCs gave satisfactory performance with long transmission lines. We also performed several experiments with a 3-DOF fiber-optic force sensor attached to the needle driver to evaluate the performance of the device in the MRI under continuous imaging. PMID:22058649

  15. Postcranial pneumaticity and bone structure in two clades of neognath birds.

    PubMed

    Gutzwiller, Sarah C; Su, Anne; O'Connor, Patrick M

    2013-06-01

    Most living birds exhibit some degree of postcranial skeletal pneumaticity, aeration of the postcranial skeleton by pulmonary air sacs and/or directly from the lungs. The extent of pneumaticity varies greatly, ranging from taxa that are completely apneumatic to those with air filling most of the postcranial skeleton. This study examined the influence of skeletal pneumatization on bone structural parameters in a sample of two size- and foraging-style diverse (e.g., subsurface diving vs. soaring specialists) clades of neognath birds (charadriiforms and pelecaniforms). Cortical bone thickness and trabecular bone volume fraction were assessed in one cervical and one thoracic vertebra in each of three pelecaniform and four charadriiform species. Results for pelecaniforms indicate that specialized subsurface dive foragers (e.g., the apneumatic anhinga) have thicker cortical bone and a higher trabecular bone volume fraction than their non-diving clademates. Conversely, the large-bodied, extremely pneumatic brown pelican (Pelecanus occidentalis) exhibits thinner cortical bone and a lower trabecular bone volume fraction. Such patterns in bone structural parameters are here interpreted to pertain to decreased buoyancy in birds specialized in subsurface dive foraging and decreased skeletal density (at the whole bone level) in birds of larger body size. The potential to differentially pneumatize the postcranial skeleton and alter bone structure may have played a role in relaxing constraints on body size evolution and/or habitat exploitation during the course of avian evolution. Notably, similar patterns were not observed within the equally diverse charadriiforms, suggesting that the relationship between pneumaticity and bone structure is variable among different clades of neognath birds. PMID:23554179

  16. Cardiovascular physiology and diseases of the rabbit.

    PubMed

    Pariaut, Romain

    2009-01-01

    This article reviews what is known about the diagnosis and management of cardiovascular diseases in the pet rabbit. Current knowledge is based on anecdotal reports, derived from research data using the rabbit as an animal model of human cardiovascular diseases, but most importantly canine and feline cardiology. It is likely that, as cardiovascular diseases are more often recognized, more specific information will soon become available for the treatment of the pet rabbit with cardiac disease.

  17. Position control of an electro-pneumatic system based on PWM technique and FLC.

    PubMed

    Najjari, Behrouz; Barakati, S Masoud; Mohammadi, Ali; Futohi, Muhammad J; Bostanian, Muhammad

    2014-03-01

    In this paper, modeling and PWM based control of an electro-pneumatic system, including the four 2-2 valves and a double acting cylinder are studied. Dynamic nonlinear behavior of the system, containing fast switching solenoid valves and a pneumatic cylinder, as well as electrical, magnetic, mechanical, and fluid subsystems are modeled. A DC-DC power converter is employed to improve solenoid valve performance and suppress system delay. Among different position control methods, a proportional integrator derivative (PID) controller and fuzzy logic controller (FLC) are evaluated. An experimental setup, using an AVR microcontroller is implemented. Simulation and experimental results verify the effectiveness of the proposed control strategies.

  18. Mathematical modeling of pneumatic char injection in a direct reduction rotary kiln

    SciTech Connect

    Ramakrishnan, V.; Sai, P.S.T.

    1999-10-01

    A one-dimensional steady-state mathematical model is proposed for direct reduction process in rotary kilns akin to the SL/RN process. The model takes into account pneumatic coal char injection from the discharge end of the kiln to supplement the heat availability. The model is based on material and energy conservation principles, and the empirical equations for kinetics and heat transfer are obtained from the literature. Predictions are carried out for both iron oxide reduction and ilmenite beneficiation processes. Improvement in the performance was predicted with pneumatic char injection.

  19. Position control of an electro-pneumatic system based on PWM technique and FLC.

    PubMed

    Najjari, Behrouz; Barakati, S Masoud; Mohammadi, Ali; Futohi, Muhammad J; Bostanian, Muhammad

    2014-03-01

    In this paper, modeling and PWM based control of an electro-pneumatic system, including the four 2-2 valves and a double acting cylinder are studied. Dynamic nonlinear behavior of the system, containing fast switching solenoid valves and a pneumatic cylinder, as well as electrical, magnetic, mechanical, and fluid subsystems are modeled. A DC-DC power converter is employed to improve solenoid valve performance and suppress system delay. Among different position control methods, a proportional integrator derivative (PID) controller and fuzzy logic controller (FLC) are evaluated. An experimental setup, using an AVR microcontroller is implemented. Simulation and experimental results verify the effectiveness of the proposed control strategies. PMID:24485509

  20. Late skin damage in rabbits and monkeys after exposure to particulate radiations

    NASA Astrophysics Data System (ADS)

    Bergtold, D. S.; Cox, A. B.; Lett, J. T.; Su, C. M.

    Skin biopsies were taken from the central regions of the ears of New Zealand white rabbits following localized exposure of one ear of each rabbit to 530 MeV/amu Ar or 365 MeV/amu Ne ions. The unirradiated ears served as controls. Biopsies were taken also from the chests and inner thighs of rhesus monkeys after whole-body exposure to 32 MeV protons and from unirradiated control animals. The linear energy transfers (LET∞'s) for the radiations were 90 +/- 5, 35 +/- 3, and ~1.2 keV/μm, respectively. In the rabbit studies, explants were removed with a 2 mm diameter dermal punch at post-irradiation times up to five years after exposure. Similar volumes of monkey tissue were taken from skin samples excised surgically 16-18 years following proton irradiation. Fibroblast cultures were initiated from the explants and were propagated in vitro until terminal senescence (cessation of cell division) occurred. Cultures from irradiated tissue exhibited decreases in doubling potential that were dependent on radiation dose and LET∞ and seemed to reflect damage to stem cell populations. The implications of these results for astronauts exposed to heavy ions and/or protons in space include possible manifestations of residual effects in the skin many years after exposure (e.g. unsatisfactory responses to trauma or surgery).

  1. Pneumatic locking device for magnetic bearing reaction wheel

    NASA Astrophysics Data System (ADS)

    Privat, Michel; da Costa, Arlindo

    2003-09-01

    Due to the launch vibration environment, the use of locking device is necessary for large or heavy mechanisms. This remark is true in particular for the inertial actuators like magnetic bearing reaction wheels. These actuators have a rotor that is in magnetic levitation without any contact with the stator. Locking device is mandatory to maintain the rotor during the launch vibrations. To avoid contact between rotor and stator during the functional phase, the link created by the locking device must be completely released. This article presents a pneumatic locking device with pyrotechnical sub-systems that have been realised by "ALCATEL Space Industries" for the reaction wheels development in the frame of a CNES satellites family. The first paragraph presents the wheel functioning and briefly describes the Electro-mechanical components of the reaction wheel. The second paragraph describes a device based on a metallic bellows ring. A nitrogen pressure in the ring allows pushing the rotor against the stator. The rotor release is obtained by drilling the system tubing with a pyrotechnic valve. The third point describes the qualification tests and the resulting data. Some functional tests are made in warm and cold case with the locking device in order to improve some mechanical characteristics including the locking effort generated and the leakage rate. Launch vibrations and thermal tests have been realised and the good functioning of the mechanism is proven. At the end of these tests, the qualification has been pronounced. The device is now implemented within the reaction wheel. This equipment should flight in 2004. The next paragraph presents the works realised under CNES Research and Technology contract. The objectives were the characterisation of metallic bellows and some technological studies to improve the knowledge of the mechanical and functional characteristics of these elements. The first study was to create a Finite Element model of a bellow in order to

  2. Tissue irradiator

    DOEpatents

    Hungate, F.P.; Riemath, W.F.; Bunnell, L.R.

    1975-12-16

    A tissue irradiator is provided for the in-vivo irradiation of body tissue. The irradiator comprises a radiation source material contained and completely encapsulated within vitreous carbon. An embodiment for use as an in- vivo blood irradiator comprises a cylindrical body having an axial bore therethrough. A radioisotope is contained within a first portion of vitreous carbon cylindrically surrounding the axial bore, and a containment portion of vitreous carbon surrounds the radioisotope containing portion, the two portions of vitreous carbon being integrally formed as a single unit. Connecting means are provided at each end of the cylindrical body to permit connections to blood- carrying vessels and to provide for passage of blood through the bore. In a preferred embodiment, the radioisotope is thulium-170 which is present in the irradiator in the form of thulium oxide. A method of producing the preferred blood irradiator is also provided, whereby nonradioactive thulium-169 is dispersed within a polyfurfuryl alcohol resin which is carbonized and fired to form the integral vitreous carbon body and the device is activated by neutron bombardment of the thulium-169 to produce the beta-emitting thulium-170.

  3. Pneumatic shutoff and time-delay valve operates at controlled rate

    NASA Technical Reports Server (NTRS)

    Horning, J. L.; Tomlinson, L. E.

    1966-01-01

    Shutoff and time delay valve, which incorporates a metering spool that moves at constant velocity under pneumatic pressure and spring compression, increases fluid-flow area at a uniform rate. Diaphragm areas, control cavity volume, and bleed-orifice size may be varied to give any desired combination of time delay and spool travel time.

  4. Numerical Simulation on the Response Characteristics of a Pneumatic Microactuator for Microfluidic Chips.

    PubMed

    Liu, Xuling; Li, Songjing; Bao, Gang

    2016-06-01

    This article presents a multiphysical system modeling and simulation of a pneumatic microactuator, which significantly influences the performance of a particular pneumatic microfluidic device. First, the multiphysical system modeling is performed by developing a physical model for each of its three integrated components: microchannel with a microvalve, a gas chamber, and an elastomer membrane. This is done for each step of operation for the whole system. The whole system is then considered a throttle blind capacitor model, and it is used to predict the response time of the pneumatic microactuator by correlating its characteristics such as gas pressurizing, hydraulic resistance, and membrane deformation. For this microactuator, when the maximum membrane deformation is 100 µm, the required actuated air pressure is 80 kPa, and the response time is 1.67 ms when the valve-opening degree is 0.8. The response time is 1.61 ms under fully open conditions. These simulated results are validated by the experimental results of the current and previous work. A correlation between the simulated and experimental results confirms that the multiphysical modeling presented in this work is applicable in developing a proper design of a pneumatic microactuator. Finally, the influencing factors of the response time are discussed and analyzed.

  5. U.S. ENVIRONMENTAL PROTECTION AGENCY'S SUPERFUND INNOVATIVE TECHNOLOGY EVALUATION OF PNEUMATIC FRACTURING EXTRACTION

    EPA Science Inventory

    The U.S. Environmental Protection Agency (EPA), in cooperation with Accutech Remedial Systems (ARS) and the New Jersey Institute of Technology (NJIT) performed a field demonstration of Pneumatic Fracturing Extraction (PFE) for the removal of chlorinated volatile organics (VOCS) f...

  6. Vacuum pressure generation via microfabricated converging-diverging nozzles for operation of automated pneumatic logic.

    PubMed

    Christoforidis, Theodore; Werner, Erik M; Hui, Elliot E; Eddington, David T

    2016-08-01

    Microfluidic devices with integrated pneumatic logic enable automated fluid handling without requiring external control instruments. These chips offer the additional advantage that they may be powered by vacuum and do not require an electricity source. This work describes a microfluidic converging-diverging (CD) nozzle optimized to generate vacuum at low input pressures, making it suitable for microfluidic applications including powering integrated pneumatic logic. It was found that efficient vacuum pressure was generated for high aspect ratios of the CD nozzle constriction (or throat) width to height and diverging angle of 3.6(o). In specific, for an inlet pressure of 42.2 psia (290.8 kPa) and a volumetric flow rate of approximately 1700 sccm, a vacuum pressure of 8.03 psia (55.3 kPa) was generated. To demonstrate the capabilities of our converging - diverging nozzle device, we connected it to a vacuum powered peristaltic pump driven by integrated pneumatic logic and obtained tunable flow rates from 0 to 130 μL/min. Finally, we demonstrate a proof of concept system for use where electricity and vacuum pressure are not readily available by powering a CD nozzle with a bicycle tire pump and pressure regulator. This system is able to produce a stable vacuum sufficient to drive pneumatic logic, and could be applied to power automated microfluidics in limited resource settings.

  7. Numerical Simulation on the Response Characteristics of a Pneumatic Microactuator for Microfluidic Chips.

    PubMed

    Liu, Xuling; Li, Songjing; Bao, Gang

    2016-06-01

    This article presents a multiphysical system modeling and simulation of a pneumatic microactuator, which significantly influences the performance of a particular pneumatic microfluidic device. First, the multiphysical system modeling is performed by developing a physical model for each of its three integrated components: microchannel with a microvalve, a gas chamber, and an elastomer membrane. This is done for each step of operation for the whole system. The whole system is then considered a throttle blind capacitor model, and it is used to predict the response time of the pneumatic microactuator by correlating its characteristics such as gas pressurizing, hydraulic resistance, and membrane deformation. For this microactuator, when the maximum membrane deformation is 100 µm, the required actuated air pressure is 80 kPa, and the response time is 1.67 ms when the valve-opening degree is 0.8. The response time is 1.61 ms under fully open conditions. These simulated results are validated by the experimental results of the current and previous work. A correlation between the simulated and experimental results confirms that the multiphysical modeling presented in this work is applicable in developing a proper design of a pneumatic microactuator. Finally, the influencing factors of the response time are discussed and analyzed. PMID:25944840

  8. Non-linear adaptive controllers for an over-actuated pneumatic MR-compatible stepper.

    PubMed

    Hollnagel, Christoph; Vallery, Heike; Schädler, Rainer; López, Isaac Gómez-Lor; Jaeger, Lukas; Wolf, Peter; Riener, Robert; Marchal-Crespo, Laura

    2013-07-01

    Pneumatics is one of the few actuation principles that can be used in an MR environment, since it can produce high forces without affecting imaging quality. However, pneumatic control is challenging, due to the air high compliance and cylinders non-linearities. Furthermore, the system's properties may change for each subject. Here, we present novel control strategies that adapt to the subject's individual anatomy and needs while performing accurate periodic gait-like movements with an MRI compatible pneumatically driven robot. In subject-passive mode, an iterative learning controller (ILC) was implemented to reduce the system's periodic disturbances. To allow the subjects to intend the task by themselves, a zero-force controller minimized the interaction forces between subject and robot. To assist patients who may be too weak, an assist-as-needed controller that adapts the assistance based on online measurement of the subject's performance was designed. The controllers were experimentally tested. The ILC successfully learned to reduce the variability and tracking errors. The zero-force controller allowed subjects to step in a transparent environment. The assist-as-needed controller adapted the assistance based on individual needs, while still challenged the subjects to perform the task. The presented controllers can provide accurate pneumatic control in MR environments to allow assessments of brain activation. PMID:23430329

  9. Optimization of pneumatic sheet extrusion of whole wheat flour poory dough using response surface methodology.

    PubMed

    Murthy, K Venkatesh; Sudha, M L; Ravi, R; Raghavarao, K S M S

    2015-07-01

    Pneumatic extrusion of whole wheat flour dough is a challenge in the preparation of Poory. In the present study, the pneumatic extrusion process variables (pneumatic pressure, rate of extrusion) and quality of deep fried product (oil uptake, frying time, puffed height) was evaluated to get Poory of maximum overall sensory quality, minimum shear and minimum oil uptake. These parameters depend on the moisture content of wheat dough. Response surface methodology was demonstrated to be an efficient tool for the optimization of process parameters of pneumatic extrusion. The results indicated that extrusion pressure ranging from 3 ~ 6 × 10(5) Pa for the whole wheat flour dough with added moisture of 56 ~ 60 % was found to give a uniform rate of extruded sheet. It was observed that submerged frying time for the extruded dough sheet was in the range of 35 ~ 40 s, with the temperature of the vegetable oil to be in the range of 180 ~ 185 °C. Oil uptake during frying was about 12 ± 1 % and the textural shear force was found to be 9.9 N with an overall sensory score of 7.2 ± 0.5 on nine point scale. The experimental errors for all attributes were non-significant (p > 0.05) and thus optimum variables predicted by the model are found suitable.

  10. Troubleshooting of an Electromechanical System (Westinghouse PLC Controlling a Pneumatic Robot). High-Technology Training Module.

    ERIC Educational Resources Information Center

    Tucker, James D.

    This training module on the troubleshooting of an electromechanical system, The Westinghouse Programmable Logic Controller (PLC) controlling a pneumatic robot, is used for a troubleshooting unit in an electromechanical systems/robotics and automation systems course. In this unit, students locate and repair a defect in a PLC-operated machine. The…

  11. Vacuum pressure generation via microfabricated converging-diverging nozzles for operation of automated pneumatic logic.

    PubMed

    Christoforidis, Theodore; Werner, Erik M; Hui, Elliot E; Eddington, David T

    2016-08-01

    Microfluidic devices with integrated pneumatic logic enable automated fluid handling without requiring external control instruments. These chips offer the additional advantage that they may be powered by vacuum and do not require an electricity source. This work describes a microfluidic converging-diverging (CD) nozzle optimized to generate vacuum at low input pressures, making it suitable for microfluidic applications including powering integrated pneumatic logic. It was found that efficient vacuum pressure was generated for high aspect ratios of the CD nozzle constriction (or throat) width to height and diverging angle of 3.6(o). In specific, for an inlet pressure of 42.2 psia (290.8 kPa) and a volumetric flow rate of approximately 1700 sccm, a vacuum pressure of 8.03 psia (55.3 kPa) was generated. To demonstrate the capabilities of our converging - diverging nozzle device, we connected it to a vacuum powered peristaltic pump driven by integrated pneumatic logic and obtained tunable flow rates from 0 to 130 μL/min. Finally, we demonstrate a proof of concept system for use where electricity and vacuum pressure are not readily available by powering a CD nozzle with a bicycle tire pump and pressure regulator. This system is able to produce a stable vacuum sufficient to drive pneumatic logic, and could be applied to power automated microfluidics in limited resource settings. PMID:27469475

  12. Aircraft Fuel, Hydraulic and Pneumatic Systems (Course Outlines), Aviation Mechanics 3 (Air Frame): 9067.01.

    ERIC Educational Resources Information Center

    Dade County Public Schools, Miami, FL.

    This document presents an outline for a 135-hour course designed to familiarize the student with the operation, inspection, and repair of aircraft fuel, hydraulic, and pneumatic systems. It is designed to help the trainee master the knowledge and skills necessary to become an aviation airframe mechanic. The aviation airframe maintenance technician…

  13. The application of pneumatic jigging in the recovery of metallic fraction from shredded printed wiring boards.

    PubMed

    Wang, Zheng; Hall, Philip; Miles, Nicholas J; Wu, Tao; Lambert, Peter; Gu, Fu

    2015-09-01

    Waste electrical and electronic equipment (WEEE) is one of the fastest growing waste streams worldwide with volumes increasing by 40% each year. WEEE has attracted increasing concern worldwide due to its high metal content and the potential environmental threat which results from uncontrolled recycling practices. Innovative physical separation techniques for WEEE recycling are preferential compared with chemical methods because of the reduction of energy and chemical consumption as well as potential environmental threats. Pneumatic jigging is a dry separation process capable of achieving good separation of coarse material within a very narrow density range, which makes it suitable as a pretreatment process for WEEE recycling. The work presented in this paper investigates the potential application of pneumatic jigging in metal recovery from WEEE. A pilot scale pneumatic jig has been developed by University of Nottingham Ningbo to separate shredded printed wiring boards into two streams: a light fraction (mainly non-metallic fraction consisting of glass fiber, fluffs, and plastic pieces) and dense fraction (metallic fraction). The novelty of work presented in this paper is the application of a dry separation technique in WEEE recycling for metal recovery. Compared with conventional wet separation processes involved in WEEE recycling industry, dry separation has the advantage of zero secondary pollution. The results of this experimental program show pneumatic jigging to be an effective and environmental friendly technique as a pretreatment process for the recovery of the metallic fraction from shredded WEEE.

  14. Evaluation of elastomers as gasket materials in pneumatic and hydraulic systems

    NASA Technical Reports Server (NTRS)

    Bright, C. W.; Lockhart, B. J.

    1972-01-01

    In the search for superior materials from which to make gaskets for pneumatic and hydraulic systems, promising materials were selected and tested. The testing was conducted in two phases. Those materials that passed the tests of Phase 1 were tested in Phase 2, and categorized in the order of preference.

  15. ACCUTECH PNEUMATIC FRACTURING EXTRACTION AND HOT GAS INJECTION, PHASE I - APPLICATIONS ANALYSIS REPORT

    EPA Science Inventory

    This document summarizes and analyzes the results of a 4-wk evaluation of the Accutech Remedial Systems, Inc. (ARS) Pneumatic Fracturing Extraction™ (PFE™) process for increasing the removal of volatile organic contaminants from the vadose zone, particularly where the ground form...

  16. LPT. Low power test (TAN641) interior. Heating and ventilating pneumatic ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    LPT. Low power test (TAN-641) interior. Heating and ventilating pneumatic and electrical control panel. Contract nearly complete. Photographer: Jack L. Anderson. Date: December 19, 1957. INEEL negative no. 57-6198 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID

  17. DETAIL OF THE EXTERNAL TANK PNEUMATIC CONTROL PANELS FOR HB2 ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    DETAIL OF THE EXTERNAL TANK PNEUMATIC CONTROL PANELS FOR HB-2 AND HB-4, SECOND LEVEL OF THE EXTERNAL TANK CHECK-OUT CELLS, HB-2, FACING EAST - Cape Canaveral Air Force Station, Launch Complex 39, Vehicle Assembly Building, VAB Road, East of Kennedy Parkway North, Cape Canaveral, Brevard County, FL

  18. 46 CFR 108.409 - Location and spacing of tubing in pneumatic fire detection system.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 4 2013-10-01 2013-10-01 false Location and spacing of tubing in pneumatic fire detection system. 108.409 Section 108.409 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS DESIGN AND EQUIPMENT Fire Extinguishing Systems § 108.409...

  19. 46 CFR 108.409 - Location and spacing of tubing in pneumatic fire detection system.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 4 2012-10-01 2012-10-01 false Location and spacing of tubing in pneumatic fire detection system. 108.409 Section 108.409 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS DESIGN AND EQUIPMENT Fire Extinguishing Systems § 108.409...

  20. 46 CFR 108.409 - Location and spacing of tubing in pneumatic fire detection system.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 4 2011-10-01 2011-10-01 false Location and spacing of tubing in pneumatic fire detection system. 108.409 Section 108.409 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS DESIGN AND EQUIPMENT Fire Extinguishing Systems § 108.409...

  1. 46 CFR 108.409 - Location and spacing of tubing in pneumatic fire detection system.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 4 2014-10-01 2014-10-01 false Location and spacing of tubing in pneumatic fire detection system. 108.409 Section 108.409 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS DESIGN AND EQUIPMENT Fire Extinguishing Systems § 108.409...

  2. Pressurization, Pneumatic, and Vent Subsystems of the X-34 Main Propulsion System

    NASA Technical Reports Server (NTRS)

    Hedayat, A.; Steadman, T. E.; Brown, T. M.; Knight, K. C.; White, C. E., Jr.; Champion, R. H., Jr.

    1998-01-01

    In pressurization systems, regulators and orifices are use to control the flow of the pressurant. For the X-34 Main Propulsion System, three pressurization subsystem design configuration options were considered. In the first option, regulators were used while in the other options, orifices were considered. In each design option, the vent/relief system must be capable of relieving the pressurant flow without allowing the tank pressure to rise above proof, therefore, impacts on the propellant tank vent system were investigated and a trade study of the pressurization system was conducted. The analysis indicated that design option using regulators poses least risk. Then, a detailed transient thermal/fluid analysis of the recommended pressurization system was performed. Helium usage, thermodynamic conditions, and overpressurization of each propellant tank were evaluated. The pneumatic and purge subsystem is used for pneumatic valve actuation, Inter-Propellant Seal purges, Engine Spin Start, and engine purges at the required interface pressures, A transient analysis of the pneumatic and purge subsystem provided helium usage and flow rates to Inter-Propellant Seal and engine interfaces. Fill analysis of the helium bottles of pressurization and pneumatic subsystems during ground operation was performed. The required fill time and the stored

  3. 49 CFR 571.117 - Standard No. 117; Retreaded pneumatic tires.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... more segments of the same ply overlap, or cord fabric that is part of the belt material, may be exposed... HIGHWAY TRAFFIC SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION FEDERAL MOTOR VEHICLE SAFETY STANDARDS... passenger car tires. S2. Purpose. The purpose of this standard is to require retreaded pneumatic...

  4. 21 CFR 874.4250 - Ear, nose, and throat electric or pneumatic surgical drill.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES EAR, NOSE, AND THROAT DEVICES Surgical Devices § 874... throat electric or pneumatic surgical drill is a rotating drilling device, including the handpiece, that... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Ear, nose, and throat electric or...

  5. 21 CFR 874.4250 - Ear, nose, and throat electric or pneumatic surgical drill.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES EAR, NOSE, AND THROAT DEVICES Surgical Devices § 874... throat electric or pneumatic surgical drill is a rotating drilling device, including the handpiece, that... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Ear, nose, and throat electric or...

  6. Development of Pneumatic Channel Wing Powered-Lift Advanced Super-STOL Aircraft

    NASA Technical Reports Server (NTRS)

    Englar, Robert J.; Campbell, Bryan A.

    2002-01-01

    The powered-lift Channel Wing concept has been combined with pneumatic Circulation Control aerodynamic and propulsive technology to generate a Pneumatic Channel Wing configuration intended to have Super-STOL or VSTOL capability while eliminating many of the operational problem areas of the original Channel Wing vehicle. A preliminary design study of this pneumatic vehicle based on previous wind-tunnel and flight-test data for the two technologies integrated into a simple Pneumatic Channel Wing (PCW) configuration showed very strong Super-STOL potential. Wind-tunnel development and evaluations of a PCW powered model conducted at Georgia Tech Research Institute (GTRI) have shown substantial lift capabilities for the blown configuration (C(sub L) values of 8.5 to 9.0). Variation in blowing of the channel was shown to be more efficient than variation in propeller thrust. Also revealed was the ability to operate unstalled at very high angles of attack of 40 deg-45 deg, or to achieve very high lift at much lower angle of attack to increase visibility and controllability. In order to provide greater flexibility in Super-STOL takeoffs and landings, the blown model also displayed the ability to interchange thrust and drag by varying blowing without any moving parts. This paper presents these experimental results, discusses variations in the configuration geometry under development, and extends this integrated technology to advanced design studies of PCW-type vehicles.

  7. 49 CFR 571.117 - Standard No. 117; Retreaded pneumatic tires.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 6 2012-10-01 2012-10-01 false Standard No. 117; Retreaded pneumatic tires. 571.117 Section 571.117 Transportation Other Regulations Relating to Transportation (Continued) NATIONAL HIGHWAY TRAFFIC SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION FEDERAL MOTOR VEHICLE SAFETY STANDARDS Federal Motor Vehicle Safety Standards...

  8. 49 CFR 571.117 - Standard No. 117; Retreaded pneumatic tires.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 6 2013-10-01 2013-10-01 false Standard No. 117; Retreaded pneumatic tires. 571.117 Section 571.117 Transportation Other Regulations Relating to Transportation (Continued) NATIONAL HIGHWAY TRAFFIC SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION FEDERAL MOTOR VEHICLE SAFETY STANDARDS Federal Motor Vehicle Safety Standards...

  9. Study made of pneumatic high pressure piping materials /10,000 psi/

    NASA Technical Reports Server (NTRS)

    Loeb, M. B.; Smith, J. C.

    1967-01-01

    Evaluations of five types of steel for use in high pressure pneumatic piping systems include tests for impact strength, tensile and yield strengths, elongation and reduction in area, field weldability, and cost. One type, AISI 4615, was selected as most advantageous for extensive use in future flight vehicles.

  10. Comparitive Assessment of Isokinetic and Pneumatic Lower Limb Strength in Functionally-Limited Elderly Subjects

    Technology Transfer Automated Retrieval System (TEKTRAN)

    The purpose of this study was to investigate the relationship between isokinetic and pneumatic knee extensor strength in functionally-limited elders and to compare the respective changes in knee extensor peak torque and one repetition maximum strength (1RM) after a randomized controlled progressive ...

  11. Mapping superficial lymphatic territories in the rabbit.

    PubMed

    Soto-Miranda, Miguel A; Suami, Hiroo; Chang, David W

    2013-06-01

    Little is known about the anatomy of the lymphatic system in the rabbit with regard to relationships between the lymphatic vessel and lymph node. According to our previous studies in human cadavers and canines, the superficial lymphatic system could be divided into lymphatic territories. The aim of this study was to completely map the superficial lymphatic system in the rabbit. We used our microinjection technique and histological analysis for dissecting studies and recently developed indocyanine green (ICG) fluorescent lymphography for demonstrating dynamic lymph flow in living rabbits. Real-time ICG fluorescent lymphography was performed in two living New Zealand White rabbits, and direct dye microinjection of the lymphatic vessels was performed in eight dead rabbits. To assess the relationships between the vascular and lymphatic systems in rabbits, we performed radiocontrast injection into arteries in two dead rabbits prior to the lymphatic injection. The ICG fluorescent lymphography revealed eight lymphatic territories in the preauricular, submandibular, root of the lateral neck, axillary, lumbar, inguinal, root of the tail, and popliteal regions. We injected blue acrylic dye into every lymphatic vessel 0.1 mm in diameter or larger. We then dissected and chased the stained lymphatic vessels proximally until the vessels connected to the first tier lymph node. This procedure was repeated throughout the body until all the relationships between the lymphatic vessels and lymph nodes were defined. The lymphatic system of the rabbit could be defined as eight lymphatic territories, each with its own lymphatic vessels and lymph node.

  12. Uterine disorders in 50 pet rabbits.

    PubMed

    Künzel, Frank; Grinninger, Petra; Shibly, Sarina; Hassan, Jasmin; Tichy, Alexander; Berghold, Petra; Fuchs-Baumgartinger, Andrea

    2015-01-01

    Although the incidence of uterine disorders in pet rabbits is high there are only a few retrospective studies and case reports on genital tract disease in female rabbits. Uterine disorders were assessed in 50 pet rabbits. In 31 pet rabbits with suspected clinical uterine disease, medical records were further reviewed regarding clinical signs, diagnostic workup, treatment as well as the outcome itself. Uterine adenocarcinoma (54%) was most frequently diagnosed, followed by endometrial hyperplasia (26%). Serosanguineous vaginal discharge was the predominant clinical sign observed by the rabbit owners. In approximately 50% of the rabbits with suspected uterine disorders, abdominal palpation revealed enlarged and/or irregular masses in the caudoventral abdomen indicating uterine lesions. Out of 23 rabbits undergoing ovariohysterectomy, four were either euthanized or died shortly after surgery because they were clinically unstable. Overall, 80% of the ovariohysterectomized animals were still alive 6 mo after surgery. In female pet rabbits that are not breeding, either ovariohysterectomy should be performed at an early age or routine checks including ultrasonography of the abdomen are recommended on a regular basis.

  13. Thermal cataract formation in rabbits

    SciTech Connect

    Kramar, P.; Harris, C.; Guy, A.W.

    1987-01-01

    Intraocularly circulating hot water was used to produce cataracts in nine eyes of seven rabbits by maintaining their retrolental temperatures between 43 degrees C and 45 degrees C. A rapid rate of heating (1.3 degrees C/min) plus a sharp temperature gradient across the eye may have been contributing factors in the consistent production of cataracts at these temperatures. Biomicroscopy and light microscopy showed lens changes similar to those associated with acute exposure to microwave radiation. These findings support the assumption that microwave cataractogenesis is due to the local production of elevated temperatures.

  14. Environmental sustainability comparison of a hypothetical pneumatic waste collection system and a door-to-door system

    SciTech Connect

    Punkkinen, Henna; Merta, Elina; Teerioja, Nea; Moliis, Katja; Kuvaja, Eveliina

    2012-10-15

    Highlights: Black-Right-Pointing-Pointer We compare the environmental sustainability of two MSW collection systems. Black-Right-Pointing-Pointer We evaluate pneumatic and door-to-door collection systems. Black-Right-Pointing-Pointer The greenhouse gas emissions of pneumatic collection are around three times higher. Black-Right-Pointing-Pointer System components are decisive but assumptions on electricity use are also important. Black-Right-Pointing-Pointer Pneumatic collection could provide other benefits over door-to-door system. - Abstract: Waste collection is one of the life cycle phases that influence the environmental sustainability of waste management. Pneumatic waste collection systems represent a new way of arranging waste collection in densely populated urban areas. However, limited information is available on the environmental impacts of this system. In this study, we compare the environmental sustainability of conventional door-to-door waste collection with its hypothetical pneumatic alternative. Furthermore, we analyse whether the size of the hypothetical pneumatic system, or the number of waste fractions included, have an impact on the results. Environmental loads are calculated for a hypothetical pneumatic waste collection system modelled on an existing dense urban area in Helsinki, Finland, and the results are compared to those of the prevailing, container-based, door-to-door waste collection system. The evaluation method used is the life-cycle inventory (LCI). In this study, we report the atmospheric emissions of greenhouse gases (GHG), SO{sub 2} and NO{sub x}. The results indicate that replacing the prevailing system with stationary pneumatic waste collection in an existing urban infrastructure would increase total air emissions. Locally, in the waste collection area, emissions would nonetheless diminish, as collection traffic decreases. While the electricity consumption of the hypothetical pneumatic system and the origin of electricity have a

  15. Additional Development and Systems Analyses of Pneumatic Technology for High Speed Civil Transport Aircraft

    NASA Technical Reports Server (NTRS)

    Englar, Robert J.; Willie, F. Scott; Lee, Warren J.

    1999-01-01

    In the Task I portion of this NASA research grant, configuration development and experimental investigations have been conducted on a series of pneumatic high-lift and control surface devices applied to a generic High Speed Civil Transport (HSCT) model configuration to determine their potential for improved aerodynamic performance, plus stability and control of higher performance aircraft. These investigations were intended to optimize pneumatic lift and drag performance; provide adequate control and longitudinal stability; reduce separation flowfields at high angle of attack; increase takeoff/climbout lift-to-drag ratios; and reduce system complexity and weight. Experimental aerodynamic evaluations were performed on a semi-span HSCT generic model with improved fuselage fineness ratio and with interchangeable plain flaps, blown flaps, pneumatic Circulation Control Wing (CCW) high-lift configurations, plain and blown canards, a novel Circulation Control (CC) cylinder blown canard, and a clean cruise wing for reference. Conventional tail power was also investigated for longitudinal trim capability. Also evaluated was unsteady pulsed blowing of the wing high-lift system to determine if reduced pulsed mass flow rates and blowing requirements could be made to yield the same lift as that resulting from steady-state blowing. Depending on the pulsing frequency applied, reduced mass flow rates were indeed found able to provide lift augmentation at lesser blowing values than for the steady conditions. Significant improvements in the aerodynamic characteristics leading to improved performance and stability/control were identified, and the various components were compared to evaluate the pneumatic potential of each. Aerodynamic results were provided to the Georgia Tech Aerospace System Design Lab. to conduct the companion system analyses and feasibility study (Task 2) of theses concepts applied to an operational advanced HSCT aircraft. Results and conclusions from these

  16. Irradiation subassembly

    DOEpatents

    Seim, O.S.; Filewicz, E.C.; Hutter, E.

    1973-10-23

    An irradiation subassembly for use in a nuclear reactor is described which includes a bundle of slender elongated irradiation -capsules or fuel elements enclosed by a coolant tube and having yieldable retaining liner between the irradiation capsules and the coolant tube. For a hexagonal bundle surrounded by a hexagonal tube the yieldable retaining liner may consist either of six segments corresponding to the six sides of the tube or three angular segments each corresponding in two adjacent sides of the tube. The sides of adjacent segments abut and are so cut that metal-tometal contact is retained when the volume enclosed by the retaining liner is varied and Springs are provided for urging the segments toward the center of the tube to hold the capsules in a closely packed configuration. (Official Gazette)

  17. Pneumatic active suspension system for a one-wheel car model using fuzzy reasoning and a disturbance observer.

    PubMed

    Yoshimura, Toshio; Takagi, Atsushi

    2004-09-01

    This paper presents the construction of a pneumatic active suspension system for a one-wheel car model using fuzzy reasoning and a disturbance observer. The one-wheel car model can be approximately described as a nonlinear two degrees of freedom system subject to excitation from a road profile. The active control is composed of fuzzy and disturbance controls, and functions by actuating a pneumatic actuator. A phase lead-lag compensator is inserted to counter the performance degradation due to the delay of the pneumatic actuator. The experimental result indicates that the proposed active suspension improves much the vibration suppression of the car model.

  18. Behavioral fever in newborn rabbits

    NASA Technical Reports Server (NTRS)

    Satinoff, E.; Mcewen, G. N., Jr.; Williams, B. A.

    1976-01-01

    New Zealand white rabbit pups aged 12 to 72 hr were divided into three groups and given an intraperitoneal injection of Pseudomonas polysaccharide, a saline vehicle alone, and no treatment, respectively. The animals injected with pyrogen and maintained at an ambient temperature of 32 C for 2 hr did not develop fever. When placed in a thermally graded alleyway, the animals injected with pyrogen selected gradient positions that represented significantly higher temperatures than controls injected with saline. Further stay at selected positions for 5 min caused a considerable increase in the rectal temperature of the pyrogen-injected pups but not that of controls. The results support the hypothesis that newborn rabbits will develop a fever by behavioral means after a single injection of an exogenous pyrogen if the opportunity for thermoregulatory behavior is present. No fever develops if the pups must rely solely on internal thermoregulatory mechanisms. The behavioral system for producing a fever is mature at birth, but an adequate system of internal reflexes does not appear to develop for some days.

  19. 9 CFR 354.124 - Quarantine of diseased rabbits.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 9 Animals and Animal Products 2 2013-01-01 2013-01-01 false Quarantine of diseased rabbits. 354... INSPECTION AND CERTIFICATION VOLUNTARY INSPECTION OF RABBITS AND EDIBLE PRODUCTS THEREOF Inspection Procedures; Ante-Mortem Inspections § 354.124 Quarantine of diseased rabbits. If live rabbits, which...

  20. 9 CFR 354.124 - Quarantine of diseased rabbits.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 9 Animals and Animal Products 2 2012-01-01 2012-01-01 false Quarantine of diseased rabbits. 354... INSPECTION AND CERTIFICATION VOLUNTARY INSPECTION OF RABBITS AND EDIBLE PRODUCTS THEREOF Inspection Procedures; Ante-Mortem Inspections § 354.124 Quarantine of diseased rabbits. If live rabbits, which...

  1. 9 CFR 354.124 - Quarantine of diseased rabbits.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 9 Animals and Animal Products 2 2011-01-01 2011-01-01 false Quarantine of diseased rabbits. 354... INSPECTION AND CERTIFICATION VOLUNTARY INSPECTION OF RABBITS AND EDIBLE PRODUCTS THEREOF Inspection Procedures; Ante-Mortem Inspections § 354.124 Quarantine of diseased rabbits. If live rabbits, which...

  2. 9 CFR 354.124 - Quarantine of diseased rabbits.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 9 Animals and Animal Products 2 2014-01-01 2014-01-01 false Quarantine of diseased rabbits. 354... INSPECTION AND CERTIFICATION VOLUNTARY INSPECTION OF RABBITS AND EDIBLE PRODUCTS THEREOF Inspection Procedures; Ante-Mortem Inspections § 354.124 Quarantine of diseased rabbits. If live rabbits, which...

  3. Clinical aspects of lagomorph dental anatomy: the rabbit (oryctolagus cuniculus).

    PubMed

    Crossley, D A

    1995-12-01

    The lagomorphs most commonly encountered as pets are rabbits. There are many breeds of domestic rabbit, varying from dwarf varieties with an adult weight of under one kilogram to giants weighing 10 kg. This article provides a working knowledge of the dental anatomy and physiology of rabbits so that veterinarians can interpret clinical and radiographic findings when investigating rabbits with suspected dental disease.

  4. Conformational changes of myosin by gamma irradiation

    NASA Astrophysics Data System (ADS)

    Lee, Ju.-Woon; Yook, Hong.-Sun; Lee, Kyong.-Haeng; Kim, Jae.-Hun; Kim, Woo.-Jung; Byun, Myung.-Woo

    2000-05-01

    Conformational and decompositional changes of bovine skeletal muscle myosin caused by gamma irradiation were studied for understanding the effects of irradiation treatment on myofibrillar proteins. Myosin solution and beef cuts were irradiated 0, 1, 3, 5 and 10 kGy. Competitive indirect enzyme linked immunosorbent assay (Ci-ELISA) showed that subunits of myosin were structurally modified with different patterns. Binding abilities of anti-myosin whole molecule and anti heavy meromyosin S-1 IgG, which were produced from rabbits, with irradiated myosin decreased in the same tendency depending upon the dose. Anti-light meromyosin IgG appeared to have the highest binding ability at 3 kGy. Irradiated beef cuts (≥5 kGy) could be identified by Ci-ELISA. Myosin solution became increasingly turbid with increasing dose. Hydrophobicity of myosin solution also increased by irradiation. Electrophoretic patterns showed that the myosin heavy chain disappeared and new bands were generated at higher molecular weight ranges.

  5. Irradiated foods

    MedlinePlus

    ... it reduces the risk of food poisoning . Food irradiation is used in many countries. It was first approved in the U.S. to prevent sprouts on white potatoes, and to control insects on wheat and in certain spices and seasonings.

  6. Late skin damage in rabbits and monkeys after exposure to particulate radiations

    NASA Technical Reports Server (NTRS)

    Bergtold, D. S.; Cox, A. B.; Lett, J. T.; Su, C. M.

    1983-01-01

    Preliminary results are reported of experiments on the late effects of exposure to particulate radiations on stem cell populations. Skin biopsies were taken from the ears of rabbits irradiated 2-5 years previously with 530 MeV/amu Ar ions (LET 90 keV/micron), or 365 MeV/amu Ne ions (LET 35 keV micron), and from the chests and inner thighs of rhesus monkeys irradiated 16-18 years previously with 32-MeV protons (LET about 1.2 keV/micron). Skin fibroblast cultures obtained from the biopsy samples in rabbits were observed to undergo dose-dependent decreases in in vitro life span, with estimated survival curves showing the effects of Ar-ion irradiation to be more severe than those of Ne-ion irradiation. In addition, the healing of the biopsy wound was observed to become slower as radiation dose increased. In the monkey, radiation reduced the average number of fibroblasts at the time of cessation of growth in culture. Results thus demonstrate the capacity of skin sampling to reveal stem cell destruction, and have important implications for astronauts and other persons at risk of particle exposure with regard to healing responses to trauma or surgery.

  7. Bobcat attack on a cottontail rabbit

    USGS Publications Warehouse

    Biggins, D.E.; Biggins, D.M.

    2006-01-01

    We observed an attack by a bobcat (Lynx rufus) on a cottontail rabbit (Sylvilagus) that involved stealthy approach by the cat for >1 h, followed by a 12.3-s chase covering 116.0 m for the cat and 128.4 m for the rabbit. During the chase, the route of the cat from starting point to kill site was more direct than the semi-circular route of the rabbit. Stride lengths for the cat and total distance covered by the chase were longer than those previously reported for bobcats.

  8. Diet-induced hypercholesterolaemia in the rabbit.

    PubMed

    Ivanov, A S; Torkhovskaya, T I; Khalilov, E M; Archakov, A I

    1991-01-01

    Intraspecies variation in diet-induced hypercholesterolaemia in rabbits, simulating atherosclerosis, was studied. The chinchilla rabbit population examined contained several subpopulations, as indicated by polymodal forms of histograms of plasma cholesterol levels. This finding indicates that the inclusion of subpopulations in an investigation can lead to erroneous conclusions, and that subpopulations should be identified before such work is undertaken. The relationship between the molar cholesterol/phospholipid ratio in rabbit erythrocyte membranes and the plasma cholesterol level in experimental atherosclerosis was also studied. A correlation was evident only over the range of 1-5 g cholesterol per litre of plasma. PMID:1751762

  9. Investigation and comparison of performance of effervescent and standard pneumatic atomizer intended for soluble aqueous coating.

    PubMed

    Nielsen, Anne Flachs; Poul, Bertelsen; Kristensen, Henning Gjelstrup; Kristensen, Jakob; Hovgaard, Lars

    2006-01-01

    Effervescent atomizers belong to the group of internal mixing atomizers. The effervescent approach might be a potential alternative to traditional atomization techniques, e.g., for applications where low atomization air consumption is advantageous In this paper, performance of one proposed design of the effervescent atomizer is investigated and compared to that of a standard pneumatic atomizer. The purpose of the comparison is to evaluate the actual potential of the specific effervescent atomizer in pharmaceutical relevant aqueous coating applications. Aqueous solutions of Hypromellose 5 as well as Povidone K-90F were characterized in terms of rheological properties and surface tension. Solutions were atomized by means of a standard Schlick pneumatic atomizer as well as a customized inside-out type effervescent atomizer. Spray droplet size distributions were recorded by a Spraytec instrument. Increased shear viscosity in the range 24-836 mPa.s had a modest effect on spray mean diameters for pneumatic sprays of the Newtonian solutions of Hypromellose 5. In contrast, mean droplet diameters increased by a factor of 3-5 in pneumatic sprays of Povidone K-90F solutions 11-175 mPa.s in viscosity, where non-Newtonian behavior was observed. Further, sprays of all solutions of Povidone K-90F have considerably larger mean droplet size. The effervescent atomizer atomized low viscosity solutions of Povidone K-90F more efficiently than Hypromellose 5 solutions of corresponding shear viscosity. However, atomization of high viscosity Povidone K-90F results in a coarser spray than that of the corresponding Hypromellose 5 solution. Viscosity, visco-elasticity, and surface tension of solutions all seem to affect atomization efficiency. The pneumatic atomizer was not sensitive to changes in airflow above 8.4 kg/h and liquid flow only had a considerable effect at suboptimal air flows. In its current design the effervescent atomizer improved efficiency throughout the investigated range

  10. Ex vivo investigations of laser auricular cartilage reshaping with carbon dioxide spray cooling in a rabbit model

    PubMed Central

    Wu, Edward C.; Sun, Victor; Manuel, Cyrus T.; Protsenko, Dmitriy E.; Jia, Wangcun; Nelson, J. Stuart; Wong, Brian J. F.

    2014-01-01

    Laser cartilage reshaping (LCR) with cryogen spray cooling is a promising modality for producing cartilage shape change while reducing cutaneous thermal injury. However, LCR in thicker tissues, such as auricular cartilage, requires higher laser power, thus increasing cooling requirements. To eliminate the risks of freeze injury characteristic of high cryogen spray pulse rates, a carbon dioxide (CO2) spray, which evaporates rapidly from the skin, has been proposed as the cooling medium. This study aims to identify parameter sets which produce clinically significant reshaping while producing minimal skin thermal injury in LCR with CO2 spray cooling in ex vivo rabbit auricular cartilage. Excised whole rabbit ears were mechanically deformed around a cylindrical jig and irradiated with a 1.45-μm wavelength diode laser (fluence 12–14 J/cm2 per pulse, four to six pulse cycles per irradiation site, five to six irradiation sites per row for four rows on each sample) with concomitant application of CO2 spray (pulse duration 33–85 ms) to the skin surface. Bend angle measurements were performed before and after irradiation, and the change quantified. Surface temperature distributions were measured during irradiation/cooling. Maximum skin surface temperature ranged between 49.0 to 97.6 °C following four heating/cooling cycles. Significant reshaping was achieved with all laser dosimetry values with a 50–70 °C difference noted between controls (no cooling) and irradiated ears. Increasing cooling pulse duration yielded progressively improved gross skin protection during irradiation. CO2 spray cooling may potentially serve as an alternative to traditional cryogen spray cooling in LCR and may be the preferred cooling medium for thicker tissues. Future studies evaluating preclinical efficacy in an in vivo rabbit model are in progress. PMID:23307439

  11. EXPERIMENTAL SYPHILIS IN THE RABBIT

    PubMed Central

    Brown, Wade H.; Pearce, Louise

    1920-01-01

    From a study of the phenomena of the primary infection on the one hand, and the phenomena of local spread, or dissemination, on the other, it is seen that a multiplicity of lesions develops in the testicle and scrotum of the rabbit which have much the same characteristics irrespective of their origin. Some of these lesions are clearly recognizable as primary lesions or parts of a primary reaction to infection, while others are just as clearly the results of dissemination of the virus from a primary focus of infection or correspond with lesions which are commonly spoken of as secondary lesions. The effort to draw a sharp line of distinction between these two groups of lesions or between a primary and a secondary stage of infection in the rabbit, however, would be largely an arbitrary procedure. The fact is that the tissues of the scrotum and testicle of the rabbit constitute favorable surroundings for the localization and development of pallidum infections. Under ordinary circumstances, a large part of the reaction to infection which expresses itself in the formation of lesions recognizable by ordinary methods of examination takes place in these tissues. These lesions present certain broad and general characteristics without regard to whether they are primary or secondary in origin; the reaction is merely a reaction to a syphilitic infection which in either case may assume the most diverse character. Further, it would appear that in rabbits infected with such strains of Treponema pallidum as we have used, the virus is never confined to the area occupied by the so called primary lesion, or chancre, but always spreads and always gives rise to a regional adenopathy. There may be no lesions to indicate the progress of this dissemination, but an examination of the inguinal nodes shows that dissemination occurs very soon after inoculation, and a pallidum reaction may be detected in these glands even before infection can be recognized in the scrotum. Subsequently lesions

  12. STATUS OF HIGH FLUX ISOTOPE REACTOR IRRADIATION OF SILICON CARBIDE/SILICON CARBIDE JOINTS

    SciTech Connect

    Katoh, Yutai; Koyanagi, Takaaki; Kiggans, Jim; Cetiner, Nesrin; McDuffee, Joel

    2014-09-01

    Development of silicon carbide (SiC) joints that retain adequate structural and functional properties in the anticipated service conditions is a critical milestone toward establishment of advanced SiC composite technology for the accident-tolerant light water reactor (LWR) fuels and core structures. Neutron irradiation is among the most critical factors that define the harsh service condition of LWR fuel during the normal operation. The overarching goal of the present joining and irradiation studies is to establish technologies for joining SiC-based materials for use as the LWR fuel cladding. The purpose of this work is to fabricate SiC joint specimens, characterize those joints in an unirradiated condition, and prepare rabbit capsules for neutron irradiation study on the fabricated specimens in the High Flux Isotope Reactor (HFIR). Torsional shear test specimens of chemically vapor-deposited SiC were prepared by seven different joining methods either at Oak Ridge National Laboratory or by industrial partners. The joint test specimens were characterized for shear strength and microstructures in an unirradiated condition. Rabbit irradiation capsules were designed and fabricated for neutron irradiation of these joint specimens at an LWR-relevant temperature. These rabbit capsules, already started irradiation in HFIR, are scheduled to complete irradiation to an LWR-relevant dose level in early 2015.

  13. Environmental sustainability comparison of a hypothetical pneumatic waste collection system and a door-to-door system.

    PubMed

    Punkkinen, Henna; Merta, Elina; Teerioja, Nea; Moliis, Katja; Kuvaja, Eveliina

    2012-10-01

    Waste collection is one of the life cycle phases that influence the environmental sustainability of waste management. Pneumatic waste collection systems represent a new way of arranging waste collection in densely populated urban areas. However, limited information is available on the environmental impacts of this system. In this study, we compare the environmental sustainability of conventional door-to-door waste collection with its hypothetical pneumatic alternative. Furthermore, we analyse whether the size of the hypothetical pneumatic system, or the number of waste fractions included, have an impact on the results. Environmental loads are calculated for a hypothetical pneumatic waste collection system modelled on an existing dense urban area in Helsinki, Finland, and the results are compared to those of the prevailing, container-based, door-to-door waste collection system. The evaluation method used is the life-cycle inventory (LCI). In this study, we report the atmospheric emissions of greenhouse gases (GHG), SO(2) and NO(x). The results indicate that replacing the prevailing system with stationary pneumatic waste collection in an existing urban infrastructure would increase total air emissions. Locally, in the waste collection area, emissions would nonetheless diminish, as collection traffic decreases. While the electricity consumption of the hypothetical pneumatic system and the origin of electricity have a significant bearing on the results, emissions due to manufacturing the system's components prove decisive.

  14. Air space proportion in pterosaur limb bones using computed tomography and its implications for previous estimates of pneumaticity.

    PubMed

    Martin, Elizabeth G; Palmer, Colin

    2014-01-01

    Air Space Proportion (ASP) is a measure of how much air is present within a bone, which allows for a quantifiable comparison of pneumaticity between specimens and species. Measured from zero to one, higher ASP means more air and less bone. Conventionally, it is estimated from measurements of the internal and external bone diameter, or by analyzing cross-sections. To date, the only pterosaur ASP study has been carried out by visual inspection of sectioned bones within matrix. Here, computed tomography (CT) scans are used to calculate ASP in a small sample of pterosaur wing bones (mainly phalanges) and to assess how the values change throughout the bone. These results show higher ASPs than previous pterosaur pneumaticity studies, and more significantly, higher ASP values in the heads of wing bones than the shaft. This suggests that pneumaticity has been underestimated previously in pterosaurs, birds, and other archosaurs when shaft cross-sections are used to estimate ASP. Furthermore, ASP in pterosaurs is higher than those found in birds and most sauropod dinosaurs, giving them among the highest ASP values of animals studied so far, supporting the view that pterosaurs were some of the most pneumatized animals to have lived. The high degree of pneumaticity found in pterosaurs is proposed to be a response to the wing bone bending stiffness requirements of flight rather than a means to reduce mass, as is often suggested. Mass reduction may be a secondary result of pneumaticity that subsequently aids flight.

  15. Air Space Proportion in Pterosaur Limb Bones Using Computed Tomography and Its Implications for Previous Estimates of Pneumaticity

    PubMed Central

    Martin, Elizabeth G.; Palmer, Colin

    2014-01-01

    Air Space Proportion (ASP) is a measure of how much air is present within a bone, which allows for a quantifiable comparison of pneumaticity between specimens and species. Measured from zero to one, higher ASP means more air and less bone. Conventionally, it is estimated from measurements of the internal and external bone diameter, or by analyzing cross-sections. To date, the only pterosaur ASP study has been carried out by visual inspection of sectioned bones within matrix. Here, computed tomography (CT) scans are used to calculate ASP in a small sample of pterosaur wing bones (mainly phalanges) and to assess how the values change throughout the bone. These results show higher ASPs than previous pterosaur pneumaticity studies, and more significantly, higher ASP values in the heads of wing bones than the shaft. This suggests that pneumaticity has been underestimated previously in pterosaurs, birds, and other archosaurs when shaft cross-sections are used to estimate ASP. Furthermore, ASP in pterosaurs is higher than those found in birds and most sauropod dinosaurs, giving them among the highest ASP values of animals studied so far, supporting the view that pterosaurs were some of the most pneumatized animals to have lived. The high degree of pneumaticity found in pterosaurs is proposed to be a response to the wing bone bending stiffness requirements of flight rather than a means to reduce mass, as is often suggested. Mass reduction may be a secondary result of pneumaticity that subsequently aids flight. PMID:24817312

  16. Evaluation of Pneumatization in the Articular Eminence and Roof of the Glenoid Fossa with Cone-Beam Computed Tomography

    PubMed Central

    İlgüy, Mehmet; Dölekoğlu, Semanur; Fişekçioğlu, Erdoğan; Ersan, Nilüfer; İlgüy, Dilhan

    2015-01-01

    Background: Detection of air cavities, so called pneumatizations, nearby to the temporomandibular joint (TMJ) area is important, as they represent sites of minimal resistance and facilitate the spread of various pathologies into the joint as inflammation, tumor or fractures and serve as a possible complicating factor in TMJ surgery. Aims: To determine the prevalence of pneumatization of the articular eminence (PAT) and roof of the glenoid fossa (PRGF) using cone-beam computed tomography (CBCT). Study Design: Cross-sectional study. Methods: Acquired images of 111 patients (222 TMJs) were evaluated. The presence of pneumatization was recorded at the articular eminence and roof of the glenoid fossa. Age and gender were recorded for all patients and type (unilocular or multilocular) and laterality were noted for the cases of pneumatization. Results: The mean age of the study group was 48.86±18.31 years. Among all the patients, 73 (65.8%) had PAT, while 13 (11.7%) had PRGF. Forty-two (37.8%) of the patients had PAT bilaterally; whereas 3 of them (2.7%) presented PRGF bilaterally. The percentage of PAT was higher for females (73.6%) than males (51.3%) (p<0.05). Conclusion: CBCT images are an accurate and reliable means of detection of the exact size and type of pneumatization and the relationship of pneumatization to the adjacent tissues. This is especially significant before a surgical intervention is planned in this region, in order to make a sound diagnosis. PMID:25759774

  17. Rabbit Models for Studying Human Infectious Diseases

    PubMed Central

    Peng, Xuwen; Knouse, John A; Hernon, Krista M

    2015-01-01

    Using an appropriate animal model is crucial for mimicking human disease conditions, and various facets including genetics, anatomy, and pathophysiology should be considered before selecting a model. Rabbits (Oryctolagus cuniculus) are well known for their wide use in production of antibodies, eye research, atherosclerosis and other cardiovascular diseases. However, a systematic description of the rabbit as primary experimental models for the study of various human infectious diseases is unavailable. This review focuses on the human infectious diseases for which rabbits are considered a classic or highly appropriate model, including AIDS (caused by HIV1), adult T-cell leukemia–lymphoma (human T-lymphotropic virus type 1), papilloma or carcinoma (human papillomavirus) , herpetic stromal keratitis (herpes simplex virus type 1), tuberculosis (Mycobacterium tuberculosis), and syphilis (Treponema pallidum). In addition, particular aspects of the husbandry and care of rabbits used in studies of human infectious diseases are described. PMID:26678367

  18. Eyeblink conditioning in the developing rabbit

    PubMed Central

    Brown, Kevin L.; Woodruff-Pak, Diana S.

    2011-01-01

    Eyeblink classical conditioning in pre-weanling rabbits was examined in the present study. Using a custom lightweight headpiece and restrainer, New Zealand white littermates were trained once daily in 400 ms delay eyeblink classical conditioning from postnatal days (PD) 17–21 or PD 24–28. These ages were chosen because eyeblink conditioning emerges gradually over PD 17–24 in rats (Stanton, Freeman, & Skelton, 1992), another altricial species with neurodevelopmental features similar to those of rabbits. Consistent with well-established findings in rats, rabbits trained from PD 24–28 showed greater conditioning relative to littermates trained from PD 17–21. Both age groups displayed poor retention of eyeblink conditioning at retraining one month after acquisition. These findings are the first to demonstrate eyeblink conditioning in the developing rabbit. With further characterization of optimal conditioning parameters, this preparation may have applications to neurodevelopmental disease models as well as research exploring the ontogeny of memory. PMID:21953433

  19. Rabbit Models for Studying Human Infectious Diseases.

    PubMed

    Peng, Xuwen; Knouse, John A; Hernon, Krista M

    2015-12-01

    Using an appropriate animal model is crucial for mimicking human disease conditions, and various facets including genetics, anatomy, and pathophysiology should be considered before selecting a model. Rabbits (Oryctolagus cuniculus) are well known for their wide use in production of antibodies, eye research, atherosclerosis and other cardiovascular diseases. However, a systematic description of the rabbit as primary experimental models for the study of various human infectious diseases is unavailable. This review focuses on the human infectious diseases for which rabbits are considered a classic or highly appropriate model, including AIDS (caused by HIV1), adult T-cell leukemia-lymphoma (human T-lymphotropic virus type 1), papilloma or carcinoma (human papillomavirus) , herpetic stromal keratitis (herpes simplex virus type 1), tuberculosis (Mycobacterium tuberculosis), and syphilis (Treponema pallidum). In addition, particular aspects of the husbandry and care of rabbits used in studies of human infectious diseases are described. PMID:26678367

  20. [Endoscopic lithotripsy with pneumatic shockwave (Swiss Lithoclast) using a mini-ureteroscope].

    PubMed

    Knispel, H H; Klän, R; Dieckmann, K P

    1993-09-01

    We performed endoscopic lithotripsy for 23 urinary stones (21 ureteral and 2 bladder stones) with a pneumatic shockwave unit (Swiss Lithoclast; EMS, Angiomed), for the first time applying the probe through the tangential working channel of a semirigid 6.9-Fr ureteroscope (Circon, ACMI). Disintegration was successful in all stones (5-24 mm). Immediately after treatment, the 2 patients with bladder calculi and 10 of the patients with ureteral stones (47.6%) were stone free, while another 5 had residual fragments < 3 mm. Migration of fragments in 4 patients (19%) led to subsequent extracorporeal shock wave lithotripsy. There were no ureteral perforations in this series. Routine application of double-J stents avoided any serious postoperative complications. Endoscopic lithotripsy with the pneumatic shockwave unit was shown to be highly effective regardless of stone composition. The ltihotripsy probe is easily applied through mini-ureteroscopes.

  1. A pneumatically controllable flexible and polymeric microfluidic valve fabricated via in situ development

    NASA Astrophysics Data System (ADS)

    Baek, Ju Yeoul; Park, Ji Young; Ju, Jong Il; Lee, Tae Soo; Lee, Sang Hoon

    2005-05-01

    In this paper, we have developed a pneumatically controllable polydimethylsiloxane (PDMS)-based microfluidic valve. This valve regulates 'On/Off' of flow using the thick centered membrane. To integrate the freely moving thick centered membrane, regional bonding of the PDMS layer is required. Here, we integrated such a membrane employing a water soluble mask as a regional bonding method, and the mask was washed out by flowing distilled water. The fabricated valve showed good 'On/Off' operations in accordance with the applied pneumatic pressure source. The flow rate could be regulated by the pressure applied to the inlet (regulated by changes in the height of the water column) and the compression-/vacuum-period ratio (this means the ratio of 'On' and 'Off' periods in each cycle) in the range of a few microliters per minute. For the durability test, ten valves were operated simultaneously one million times, and no failed valves were observed.

  2. Characterization of a pneumatic balloon actuator for use in refreshable Braille displays.

    PubMed

    Fan, Richard E; Feinman, Adam M; Wottawa, Christopher; King, Chih-Hung; Franco, Miguel L; Dutson, Erik P; Grundfest, Warren S; Culjat, Martin O

    2009-01-01

    Many existing refreshable Braille display technologies are costly or lack robust performance. A process has been developed to fabricate consistent and reliable pneumatic balloon actuators at low material cost, using a novel manufacturing process. This technique has been adapted for use in refreshable Braille displays that feature low power consumption, ease of manufacture and small form factor. A prototype refreshable cell, conforming to American Braille standards, was developed and tested. The cell was fabricated from molded PDMS to form balloon actuators with a spin-coated silicone film, and fast pneumatic driving elements and an electronic control system were developed to drive the Braille dots. Perceptual testing was performed to determine the feasibility of the approach using a single blind human subject. The subject was able to detect randomized Braille letters rapidly generated by the actuator with 100% character detection accuracy.

  3. Characterization of a pneumatic balloon actuator for use in refreshable Braille displays.

    PubMed

    Fan, Richard E; Feinman, Adam M; Wottawa, Christopher; King, Chih-Hung; Franco, Miguel L; Dutson, Erik P; Grundfest, Warren S; Culjat, Martin O

    2009-01-01

    Many existing refreshable Braille display technologies are costly or lack robust performance. A process has been developed to fabricate consistent and reliable pneumatic balloon actuators at low material cost, using a novel manufacturing process. This technique has been adapted for use in refreshable Braille displays that feature low power consumption, ease of manufacture and small form factor. A prototype refreshable cell, conforming to American Braille standards, was developed and tested. The cell was fabricated from molded PDMS to form balloon actuators with a spin-coated silicone film, and fast pneumatic driving elements and an electronic control system were developed to drive the Braille dots. Perceptual testing was performed to determine the feasibility of the approach using a single blind human subject. The subject was able to detect randomized Braille letters rapidly generated by the actuator with 100% character detection accuracy. PMID:19377122

  4. Investigation of work parameters of SI engine dedicated to energetics aggregates with pneumatic injection system

    NASA Astrophysics Data System (ADS)

    Marek, W.; Śliwiński, K.

    2016-09-01

    The article presents the possibilities of alternative fuel combustion in the engine four- stroke spark ignition engines. Power of the motor was carried out pneumatic fuel injection system using a hot gas developed by Prof. Stanislaw Jarnuszkiewicz. Presented made the position of the measuring system with the power and results. The engine experimental at the time of the study was powered by a blend of alcohol and gasoline. The main aim of the study was the question of control fuel dosage, taking into account the energy needs of forcing the engine load. During the tests carried load characteristics control the motor using the power control quality. Another issue was the elimination of penetration of fuel to the engine lubrication system, a problem occurred in the initial study on the issue of the pneumatic fuel injection using the hot exhaust gases. In summary we present the findings of this phase of the study.

  5. A comparison of hydraulic, pneumatic, and electro-mechanical actuators for general aviation flight controls

    NASA Technical Reports Server (NTRS)

    Roskam, J.; Rice, M.; Eysink, H.

    1979-01-01

    Mathematical models for electromechanical (EM), pneumatic and hydraulic actuations are discussed. It is shown that EM and hydraulic actuators provide better and faster time responses than pneumatic actuators but EM actuators utilizing the recently developed samarium-cobalt technology have significant advantages in terms of size, weight and power requirements. In terms of ease and flexibility of installation EM actuators apparently have several advantages over hydraulic actuators, and cost is a primary reason for the popularity of EM actuation for secondary control function since no additional systems need to be added to the aircraft. While new rare earth magnets are currently in developmental stage, costs are relatively high; but continued research should bring prices down.

  6. Applicability of Pneumatic Capsule Pipeline System to Radioactive Waste Disposal Facility

    SciTech Connect

    Hane, K.; Okutsu, K.; Matsui, N.; Kosugi, S.

    2002-02-25

    Various transport systems have been studied for the transportation of waste packages and buffer materials from the ground surface to the underground radioactive waste disposal facility, such as a lift (vertical shaft type) and a vehicle (inclined tunnel type)(1). This paper introduces pneumatic capsule pipeline system as a new method for the transportation. The system is designed to transport pneumatically waste packages and buffer materials between the surface and the underground as shown in Fig. 1. The system is also used to transport excavated debris, equipment and materials during construction. It is economical to utilize the system for air ventilation in addition to be used for transportation. The capsule moving in the shaft can be controlled at appropriate speed by adjusting the air pressure in the shaft. This paper discusses the applicability of the system to the geological disposal based on analytical simulation and experimental study.

  7. Oritavancin Pharmacokinetics and Bone Penetration in Rabbits

    PubMed Central

    Ostiguy, Valerie; Cadieux, Cordelia; Malouin, Mireille; Belanger, Odette; Far, Adel Rafai; Parr, Thomas R.

    2015-01-01

    The pharmacokinetics and bone concentrations of oritavancin were investigated after a single intravenous dose was administered to rabbits. The pharmacokinetic profile of oritavancin in rabbits showed that it is rapidly distributed to bone tissues, with concentrations remaining stable for up to 168 h, the last measured time point. Based on these findings, further evaluation of oritavancin for the treatment of infections in bone tissues is warranted. PMID:26239977

  8. Development of Pneumatic Aerodynamic Devices to Improve the Performance, Economics, and Safety of Heavy Vehicles

    SciTech Connect

    Robert J. Englar

    2000-06-19

    Under contract to the DOE Office of Heavy Vehicle Technologies, the Georgia Tech Research Institute (GTRI) is developing and evaluating pneumatic (blown) aerodynamic devices to improve the performance, economics, stability and safety of operation of Heavy Vehicles. The objective of this program is to apply the pneumatic aerodynamic aircraft technology previously developed and flight-tested by GTRI personnel to the design of an efficient blown tractor-trailer configuration. Recent experimental results obtained by GTRI using blowing have shown drag reductions of 35% on a streamlined automobile wind-tunnel model. Also measured were lift or down-load increases of 100-150% and the ability to control aerodynamic moments about all 3 axes without any moving control surfaces. Similar drag reductions yielded by blowing on bluff afterbody trailers in current US trucking fleet operations are anticipated to reduce yearly fuel consumption by more than 1.2 billion gallons, while even further reduction is possible using pneumatic lift to reduce tire rolling resistance. Conversely, increased drag and down force generated instantaneously by blowing can greatly increase braking characteristics and control in wet/icy weather due to effective ''weight'' increases on the tires. Safety is also enhanced by controlling side loads and moments caused on these Heavy Vehicles by winds, gusts and other vehicles passing. This may also help to eliminate the jack-knifing problem if caused by extreme wind side loads on the trailer. Lastly, reduction of the turbulent wake behind the trailer can reduce splash and spray patterns and rough air being experienced by following vehicles. To be presented by GTRI in this paper will be results developed during the early portion of this effort, including a preliminary systems study, CFD prediction of the blown flowfields, and design of the baseline conventional tractor-trailer model and the pneumatic wind-tunnel model.

  9. Does Pneumatic Tube System Transport Contribute to Hemolysis in ED Blood Samples?

    PubMed Central

    Phelan, Michael P.; Reineks, Edmunds Z.; Hustey, Fredric M.; Berriochoa, Jacob P.; Podolsky, Seth R.; Meldon, Stephen; Schold, Jesse D.; Chamberlin, Janelle; Procop, Gary W.

    2016-01-01

    Introduction Our goal was to determine if the hemolysis among blood samples obtained in an emergency department and then sent to the laboratory in a pneumatic tube system was different from those in samples that were hand-carried. Methods The hemolysis index is measured on all samples submitted for potassium analysis. We queried our hospital laboratory database system (SunQuest®) for potassium results for specimens obtained between January 2014 and July 2014. From facility maintenance records, we identified periods of system downtime, during which specimens were hand-carried to the laboratory. Results During the study period, 15,851 blood specimens were transported via our pneumatic tube system and 92 samples were hand delivered. The proportions of hemolyzed specimens in the two groups were not significantly different (13.6% vs. 13.1% [p=0.90]). Results were consistent when the criterion was limited to gross (3.3% vs 3.3% [p=0.99]) or mild (10.3% vs 9.8% [p=0.88]) hemolysis. The hemolysis rate showed minimal variation during the study period (12.6%–14.6%). Conclusion We found no statistical difference in the percentages of hemolyzed specimens transported by a pneumatic tube system or hand delivered to the laboratory. Certain features of pneumatic tube systems might contribute to hemolysis (e.g., speed, distance, packing material). Since each system is unique in design, we encourage medical facilities to consider whether their method of transport might contribute to hemolysis in samples obtained in the emergency department. PMID:27625719

  10. Development and utilization of new diagnostics for dense-phase pneumatic transport

    SciTech Connect

    Louge, M.; Jenkins, J.T.

    1992-03-02

    In 1988, we proposed a program to develop new diagnostics for dense gas-solid suspensions, with particular interest toward the dense pneumatic transport of cohesive solid plugs. This program included three main objectives, as follows: to develop probes for local measurements of (1) local particle volume fraction and (2) individual particle velocities in dense gas-solid flows; and (3) to construct a bench-scale setup for transporting dense cohesive solid plugs and to analyze data from the resulting tests.

  11. Development and utilization of new diagnostics for dense-phase pneumatic transport. Final report

    SciTech Connect

    Louge, M.; Jenkins, J.T.

    1992-03-02

    In 1988, we proposed a program to develop new diagnostics for dense gas-solid suspensions, with particular interest toward the dense pneumatic transport of cohesive solid plugs. This program included three main objectives, as follows: to develop probes for local measurements of (1) local particle volume fraction and (2) individual particle velocities in dense gas-solid flows; and (3) to construct a bench-scale setup for transporting dense cohesive solid plugs and to analyze data from the resulting tests.

  12. Hydraulic anisotropy characterization of pneumatic-fractured sediments using azimuthal self potential gradient

    USGS Publications Warehouse

    Wishart, D.N.; Slater, L.D.; Schnell, D.L.; Herman, G.C.

    2009-01-01

    The pneumatic fracturing technique is used to enhance the permeability and porosity of tight unconsolidated soils (e.g. clays), thereby improving the effectiveness of remediation treatments. Azimuthal self potential gradient (ASPG) surveys were performed on a compacted, unconsolidated clay block in order to evaluate their potential to delineate contaminant migration pathways in a mechanically-induced fracture network. Azimuthal resistivity (ARS) measurements were also made for comparative purposes. Following similar procedures to those used in the field, compressed kaolinite sediments were pneumatically fractured and the resulting fracture geometry characterized from strike analysis of visible fractures combined with strike data from optical borehole televiewer (BHTV) imaging. We subsequently injected a simulated treatment (electrolyte/dye) into the fractures. Both ASPG and ARS data exhibit anisotropic geoelectric signatures resulting from the fracturing. Self potentials observed during injection of electrolyte are consistent with electrokinetic theory and previous laboratory results on a fracture block model. Visual (polar plot) analysis and linear regression of cross plots show ASPG lobes are correlated with azimuths of high fracture strike density, evidence that the ASPG anisotropy is a proxy measure of hydraulic anisotropy created by the pneumatic fracturing. However, ARS data are uncorrelated with fracture strike maxima and resistivity anisotropy is probably dominated by enhanced surface conduction along azimuths of weak 'starter paths' formed from pulverization of the clay and increases in interfacial surface area. We find the magnitude of electrokinetic SP scales with the applied N2 gas pressure gradient (??PN2) for any particular hydraulically-active fracture set and that the positive lobe of the ASPG anomaly indicates the flow direction within the fracture network. These findings demonstrate the use of ASPG in characterizing the effectiveness of (1

  13. Feasibility and testing of lighweight, energy efficient, additive manufactured pneumatic control valve

    SciTech Connect

    Love, Lonnie J.; Mell, Ellen

    2015-02-01

    AeroValve s innovative pneumatic valve technology recycles compressed air through the valve body with each cycle of the valve, and was reported to reduce compressed air requirements by an average of 25% 30%.This technology collaboration project between ORNL and Aerovalve confirms the energy efficiency of valve performance. Measuring air consumption per work completed, the AeroValve was as much as 85% better than the commercial Festo valve.

  14. NK-1 Removable Cryogenic Shroud (A Study of the Bimba Pneumatic Cylinder)

    SciTech Connect

    Anderson, K; Stefanescu, D

    2003-02-07

    The Mark 1 Cryostat requires a cryogenic shroud that must be retracted immediately before firing the NIF laser. This paper evaluates a pneumatic cylinder that has been chosen to open and close the shroud. After a variety of motion control and vacuum compatibility experiments, we concluded that the Bimba feedback control cylinder may be used to retract the shroud with certain modifications to its control system and additional rod seals.

  15. Does Pneumatic Tube System Transport Contribute to Hemolysis in ED Blood Samples?

    PubMed Central

    Phelan, Michael P.; Reineks, Edmunds Z.; Hustey, Fredric M.; Berriochoa, Jacob P.; Podolsky, Seth R.; Meldon, Stephen; Schold, Jesse D.; Chamberlin, Janelle; Procop, Gary W.

    2016-01-01

    Introduction Our goal was to determine if the hemolysis among blood samples obtained in an emergency department and then sent to the laboratory in a pneumatic tube system was different from those in samples that were hand-carried. Methods The hemolysis index is measured on all samples submitted for potassium analysis. We queried our hospital laboratory database system (SunQuest®) for potassium results for specimens obtained between January 2014 and July 2014. From facility maintenance records, we identified periods of system downtime, during which specimens were hand-carried to the laboratory. Results During the study period, 15,851 blood specimens were transported via our pneumatic tube system and 92 samples were hand delivered. The proportions of hemolyzed specimens in the two groups were not significantly different (13.6% vs. 13.1% [p=0.90]). Results were consistent when the criterion was limited to gross (3.3% vs 3.3% [p=0.99]) or mild (10.3% vs 9.8% [p=0.88]) hemolysis. The hemolysis rate showed minimal variation during the study period (12.6%–14.6%). Conclusion We found no statistical difference in the percentages of hemolyzed specimens transported by a pneumatic tube system or hand delivered to the laboratory. Certain features of pneumatic tube systems might contribute to hemolysis (e.g., speed, distance, packing material). Since each system is unique in design, we encourage medical facilities to consider whether their method of transport might contribute to hemolysis in samples obtained in the emergency department.

  16. Hydraulic anisotropy characterization of pneumatic-fractured sediments using azimuthal self potential gradient

    NASA Astrophysics Data System (ADS)

    Wishart, DeBonne N.; Slater, Lee D.; Schnell, Deborah L.; Herman, Gregory C.

    2009-01-01

    The pneumatic fracturing technique is used to enhance the permeability and porosity of tight unconsolidated soils (e.g. clays), thereby improving the effectiveness of remediation treatments. Azimuthal self potential gradient (ASPG) surveys were performed on a compacted, unconsolidated clay block in order to evaluate their potential to delineate contaminant migration pathways in a mechanically-induced fracture network. Azimuthal resistivity (ARS) measurements were also made for comparative purposes. Following similar procedures to those used in the field, compressed kaolinite sediments were pneumatically fractured and the resulting fracture geometry characterized from strike analysis of visible fractures combined with strike data from optical borehole televiewer (BHTV) imaging. We subsequently injected a simulated treatment (electrolyte/dye) into the fractures. Both ASPG and ARS data exhibit anisotropic geoelectric signatures resulting from the fracturing. Self potentials observed during injection of electrolyte are consistent with electrokinetic theory and previous laboratory results on a fracture block model. Visual (polar plot) analysis and linear regression of cross plots show ASPG lobes are correlated with azimuths of high fracture strike density, evidence that the ASPG anisotropy is a proxy measure of hydraulic anisotropy created by the pneumatic fracturing. However, ARS data are uncorrelated with fracture strike maxima and resistivity anisotropy is probably dominated by enhanced surface conduction along azimuths of weak 'starter paths' formed from pulverization of the clay and increases in interfacial surface area. We find the magnitude of electrokinetic SP scales with the applied N 2 gas pressure gradient (Δ PN2) for any particular hydraulically-active fracture set and that the positive lobe of the ASPG anomaly indicates the flow direction within the fracture network. These findings demonstrate the use of ASPG in characterizing the effectiveness of (1

  17. Pneumatic colon injury following high pressure blow gun dust cleaner spray to the perineum

    PubMed Central

    Sy, Edgar D.; Chiu, Yin-I.; Shan, Yan-Shen; Ong, Roger L.

    2014-01-01

    Introduction A pneumatic tool or air tool such as blow gun dust cleaner is a tool driven by compressed air and spraying of the perineum can insufflate the colon due to its high pressure and high flow rate. Presentation of case We present a case of 4 year old boy who developed sudden onset of tense abdominal distention and developed peritonitis. Patient’s family initially denied a history of trauma. Radiologic examination showed pneumoperitoneum and colon dilatation. Exploratory laparotomy revealed a tension pneumoperitoneum, bloody ascitic fluid, multiple site of ecchymosis and serosal tear of the colon and a minute perforation of transverse colon. Postoperative reinvestigation revealed that the patient’s perineum was sprayed, using blow gun dust cleaner. Discussion Air from pneumatic tools produces column of air at pressure of 3.5–8.8 kg/cm2 and pressure greater than the resting anal pressure of 0.109 kg/cm2 force air to enter the colon when the perineum is sprayed. Different degree of colon injury results when airflow is greater than 1.46 L/m, and/or intraluminal pressure greater than 0.109 kg/cm2. In most children, initial anxiety to tell the truth result in difficulty to obtain good history. Conclusion Spraying of the perianal with excessive pneumatic force of greater than the resting anal pressure and high air flow rate causes multiple site colon injury and tension pneumoperitoneum due to colon perforation. Parent should be caution in children playing with high pressure pneumatic tool, and the importance of history is emphases for early correct diagnosis. PMID:25544492

  18. Genomic Analysis of Companion Rabbit Staphylococcus aureus

    PubMed Central

    Holmes, Mark A.; Harrison, Ewan M.; Fisher, Elizabeth A.; Graham, Elizabeth M.; Parkhill, Julian; Foster, Geoffrey; Paterson, Gavin K.

    2016-01-01

    In addition to being an important human pathogen, Staphylococcus aureus is able to cause a variety of infections in numerous other host species. While the S. aureus strains causing infection in several of these hosts have been well characterised, this is not the case for companion rabbits (Oryctolagus cuniculus), where little data are available on S. aureus strains from this host. To address this deficiency we have performed antimicrobial susceptibility testing and genome sequencing on a collection of S. aureus isolates from companion rabbits. The findings show a diverse S. aureus population is able to cause infection in this host, and while antimicrobial resistance was uncommon, the isolates possess a range of known and putative virulence factors consistent with a diverse clinical presentation in companion rabbits including severe abscesses. We additionally show that companion rabbit isolates carry polymorphisms within dltB as described as underlying host-adaption of S. aureus to farmed rabbits. The availability of S. aureus genome sequences from companion rabbits provides an important aid to understanding the pathogenesis of disease in this host and in the clinical management and surveillance of these infections. PMID:26963381

  19. Genomic Analysis of Companion Rabbit Staphylococcus aureus.

    PubMed

    Holmes, Mark A; Harrison, Ewan M; Fisher, Elizabeth A; Graham, Elizabeth M; Parkhill, Julian; Foster, Geoffrey; Paterson, Gavin K

    2016-01-01

    In addition to being an important human pathogen, Staphylococcus aureus is able to cause a variety of infections in numerous other host species. While the S. aureus strains causing infection in several of these hosts have been well characterised, this is not the case for companion rabbits (Oryctolagus cuniculus), where little data are available on S. aureus strains from this host. To address this deficiency we have performed antimicrobial susceptibility testing and genome sequencing on a collection of S. aureus isolates from companion rabbits. The findings show a diverse S. aureus population is able to cause infection in this host, and while antimicrobial resistance was uncommon, the isolates possess a range of known and putative virulence factors consistent with a diverse clinical presentation in companion rabbits including severe abscesses. We additionally show that companion rabbit isolates carry polymorphisms within dltB as described as underlying host-adaption of S. aureus to farmed rabbits. The availability of S. aureus genome sequences from companion rabbits provides an important aid to understanding the pathogenesis of disease in this host and in the clinical management and surveillance of these infections. PMID:26963381

  20. Genomic Analysis of Companion Rabbit Staphylococcus aureus.

    PubMed

    Holmes, Mark A; Harrison, Ewan M; Fisher, Elizabeth A; Graham, Elizabeth M; Parkhill, Julian; Foster, Geoffrey; Paterson, Gavin K

    2016-01-01

    In addition to being an important human pathogen, Staphylococcus aureus is able to cause a variety of infections in numerous other host species. While the S. aureus strains causing infection in several of these hosts have been well characterised, this is not the case for companion rabbits (Oryctolagus cuniculus), where little data are available on S. aureus strains from this host. To address this deficiency we have performed antimicrobial susceptibility testing and genome sequencing on a collection of S. aureus isolates from companion rabbits. The findings show a diverse S. aureus population is able to cause infection in this host, and while antimicrobial resistance was uncommon, the isolates possess a range of known and putative virulence factors consistent with a diverse clinical presentation in companion rabbits including severe abscesses. We additionally show that companion rabbit isolates carry polymorphisms within dltB as described as underlying host-adaption of S. aureus to farmed rabbits. The availability of S. aureus genome sequences from companion rabbits provides an important aid to understanding the pathogenesis of disease in this host and in the clinical management and surveillance of these infections.

  1. Morphing nacelle inlet lip with pneumatic actuators and a flexible nano composite sandwich panel

    NASA Astrophysics Data System (ADS)

    Gulsine Ozdemir, Nazli; Scarpa, Fabrizio; Craciun, Monica; Remillat, Chrystel; Lira, Cristian; Jagessur, Yogesh; Da Rocha-Schmidt, Luiz

    2015-12-01

    We present a hybrid pneumatic/flexible sandwich structure with thermoplastic (TP) nanocomposite skins to enable the morphing of a nacelle inlet lip. The design consists of pneumatic inflatables as actuators and a flexible sandwich panel that morphs under variable pressure combinations to adapt different flight conditions and save fuel. The sandwich panel forms the outer layer of the nacelle inlet lip. It is lightweight, compliant and impact resistant with no discontinuities, and consists of graphene-doped thermoplastic polyurethane (G/TPU) skins that are supported by an aluminium Flex-core honeycomb in the middle, with near zero in-plane Poisson’s ratio behaviour. A test rig for a reduced-scale demonstrator was designed and built to test the prototype of morphing nacelle with custom-made pneumatic actuators. The output force and the deflections of the experimental demonstrator are verified with the internal pressures of the actuators varying from 0 to 0.41 MPa. The results show the feasibility and promise of the hybrid inflatable/nanocomposite sandwich panel for morphing nacelle airframes.

  2. Pneumatic pulsator design as an example of numerical simulations in engineering applications

    NASA Astrophysics Data System (ADS)

    Wołosz, Krzysztof; Wernik, Jacek

    2012-03-01

    The paper presents the part of the investigation that has been carried out in order to develop the pneumatic pulsator which is to be employed as an unblocking device at lose material silo outlets. The part of numerical simulation is reported. The fluid dynamics issues have been outlined which are present during supersonic airflow thought the head of the pulsator. These issues describe the pneumatic impact phenomenon onto the loose material bed present in the silo to which walls the pulsator is assembled. The investigation presented in the paper are industrial applicable and the result is the working prototype of the industrial pneumatic pulsator. The numerical simulation has led to change the piston shape which is moving inside the head of the pulsator, and therefore, to reduce the pressure losses during the airflow. A stress analysis of the pulsator controller body has been carried out while the numerical simulation investigation part of the whole project. The analysis has made possible the change of the controller body material from cast iron to aluminium alloy.

  3. Dynamics of a pneumatic artificial muscle actuation system driving a trailing edge flap

    NASA Astrophysics Data System (ADS)

    Woods, Benjamin K. S.; Kothera, Curt S.; Wang, Gang; Wereley, Norman M.

    2014-09-01

    This study presents a time domain dynamic model of an antagonistic pneumatic artificial muscle (PAM) driven trailing edge flap (TEF) system for next generation active helicopter rotors. Active rotor concepts are currently being widely researched in the rotorcraft community as a means to provide a significant leap forward in performance through primary aircraft control, vibration mitigation and noise reduction. Recent work has shown PAMs to be a promising candidate for active rotor actuation due to their combination of high force, large stroke, light weight, and suitable bandwidth. When arranged into biologically inspired agonist/antagonist muscle pairs they can produce bidirectional torques for effectively driving a TEF. However, there are no analytical dynamic models in the literature that can accurately capture the behavior of such systems across the broad range of frequencies required for this demanding application. This work combines mechanical, pneumatic, and aerodynamic component models into a global flap system model developed for the Bell 407 rotor system. This model can accurately predict pressure, force, and flap angle response to pneumatic control valve inputs over a range of operating frequencies from 7 to 35 Hz (1/rev to 5/rev for the Bell 407) and operating pressures from 30 to 90 psi.

  4. Extreme Mechanics in Soft Pneumatic Robots and Soft Microfluidic Electronics and Sensors

    NASA Astrophysics Data System (ADS)

    Majidi, Carmel

    2012-02-01

    In the near future, machines and robots will be completely soft, stretchable, impact resistance, and capable of adapting their shape and functionality to changes in mission and environment. Similar to biological tissue and soft-body organisms, these next-generation technologies will contain no rigid parts and instead be composed entirely of soft elastomers, gels, fluids, and other non-rigid matter. Using a combination of rapid prototyping tools, microfabrication methods, and emerging techniques in so-called ``soft lithography,'' scientists and engineers are currently introducing exciting new families of soft pneumatic robots, soft microfluidic sensors, and hyperelastic electronics that can be stretched to as much as 10x their natural length. Progress has been guided by an interdisciplinary collection of insights from chemistry, life sciences, robotics, microelectronics, and solid mechanics. In virtually every technology and application domain, mechanics and elasticity have a central role in governing functionality and design. Moreover, in contrast to conventional machines and electronics, soft pneumatic systems and microfluidics typically operate in the finite deformation regime, with materials stretching to several times their natural length. In this talk, I will review emerging paradigms in soft pneumatic robotics and soft microfluidic electronics and highlight modeling and design challenges that arise from the extreme mechanics of inflation, locomotion, sensor operation, and human interaction. I will also discuss perceived challenges and opportunities in a broad range of potential application, from medicine to wearable computing.

  5. The maxillary sinus in three genera of new world monkeys: factors that constrain secondary pneumatization.

    PubMed

    Smith, Timothy D; Rossie, James B; Cooper, Gregory M; Carmody, Kelly A; Schmieg, Robin M; Bonar, Christopher J; Mooney, Mark P; Siegel, Michael I

    2010-01-01

    The air filled cavities of paranasal sinuses are thought by some to appear opportunistically in spatial "gaps" within the craniofacial complex. Anthropoid primates provide excellent natural experiments for testing this model, since not all species possess a full complement of paranasal sinuses. In this study, two genera of monkeys (Saguinus and Cebuella) which form maxillary sinuses (MS) as adults were compared to squirrel monkeys (Saimiri spp.), in which a MS does not form. Using microCT and histomorphometric methods, the spatial position of paranasal spaces was assessed and size of the adjacent dental sacs was measured. In Saguinus, secondary pneumatization is underway perinatally, and the sinus extends alongside deciduous premolars (dp). The MS overlaps all permanent molars in the adult. In Saimiri, the homologous space (maxillary recess) extends no farther posterior than the first deciduous premolar at birth and extends no farther than the last premolar in the adult. Differences in dental size and position may account for this finding. For example, Saimiri has significantly larger relative dp volumes, and enlarged orbits, which encroach on the internasal space to a greater degree when compared to Saguinus. These factors limit space for posterior expansion of the maxillary recess. These findings support the hypothesis that secondary pneumatization is a novel, opportunistic growth mechanism that removes "unneeded" bone. Moreover, paranasal spaces occur in association with semiautonomous skeletal elements that border more than one functional matrix, and the spatial dynamics of these units can act as a constraint on pneumatic expansion of paranasal spaces.

  6. Fueling of magnetically confined plasmas by single- and two-stage repeating pneumatic pellet injectors

    SciTech Connect

    Gouge, M.J.; Combs, S.K.; Foust, C.R.; Milora, S.L.

    1990-01-01

    Advanced plasma fueling systems for magnetic fusion confinement experiments are under development at Oak Ridge National Laboratory (ORNL). The general approach is that of producing and accelerating frozen hydrogenic pellets to speeds in the kilometer-per-second range using single shot and repetitive pneumatic (light-gas gun) pellet injectors. The millimeter-to-centimeter size pellets enter the plasma and continuously ablate because of the plasma electron heat flux, depositing fuel atoms along the pellet trajectory. This fueling method allows direct fueling in the interior of the hot plasma and is more efficient than the alternative method of injecting room temperature fuel gas at the wall of the plasma vacuum chamber. Single-stage pneumatic injectors based on the light-gas gun concept have provided hydrogenic fuel pellets in the speed range of 1--2 km/s in single-shot injector designs. Repetition rates up to 5 Hz have been demonstrated in repetitive injector designs. Future fusion reactor-scale devices may need higher pellet velocities because of the larger plasma size and higher plasma temperatures. Repetitive two-stage pneumatic injectors are under development at ORNL to provide long-pulse plasma fueling in the 3--5 km/s speed range. Recently, a repeating, two-stage light-gas gun achieved repetitive operation at 1 Hz with speeds in the range of 2--3 km/s.

  7. Development and utilization of new diagnostics for dense-phase pneumatic transport

    SciTech Connect

    Not Available

    1991-01-01

    Dense-phase pneumatic transport is an attractive means of conveying solids. Unfortunately, because of the high solid concentrations, this transport method is a difficult regime in which to carry out detailed measurements. Hence most details of the flow are unknown. In this context, the main objective of this work is to develop probes for local measurements of solid velocity and holdup in dense gas-solid flows. Because we anticipate the recent theories of rapid granular flows will bring insight to the dense pneumatic transport of particles, we have sought to substantiate these theories through computer simulations. There we have verified the theory of Hanes, Jenkins Richman (1988) for the rapid, steady shear flow of identical, smooth, nearly elastics disks driven by identical, parallel, bumpy boundaries. Because granular flows depend strongly on the nature of their interaction with a boundary, we have verified the boundary conditions calculated by Jenkins (1991) for spheres interacting with a flat, frictional surface. During the previous reporting period, we began a study of the time relaxation of the second moment of velocity fluctuations for a collection of disks undergoing simple shear. In the present reporting period, we have completed this study of relaxation by comparing results of simulations with the theoretical predictions of Jenkins and Richman (1988). In addition, we have concluded a series of experiments with flour plugs in the dense-phase pneumatic setup. Finally, we have established several industrial contacts to transfer the diagnostic techniques developed under this contract. 7 refs., 11 figs.

  8. Continued Development and Application of Circulation Control Pneumatic Technology to Advanced Transport Aircraft

    NASA Technical Reports Server (NTRS)

    Englar, Robert J.

    1998-01-01

    Personnel of the Georgia Tech Research Institute (GTRI) Aerospace and Transportation Lab have completed a four-year grant program to develop and evaluate the pneumatic aerodynamic technology known as Circulation Control (CC) or Circulation Control Wing (CCW) for advanced transport aircraft. This pneumatic technology, which employs low-level blowing from tangential slots over round or near-round trailing edges of airfoils, greatly augments the circulation around a lifting or control surface and thus enhances the aerodynamic forces and moments generated by that surface. Two-dimensional force augmentations as high as 80 times the input blowing momentum coefficient have been recorded experimentally for these blown devices, thus providing returns of 8000% on the jet momentum expended. A further benefit is the absence of moving parts such as mechanical flaps, slats, spoilers, ailerons, elevators and rudders from these pneumatic surfaces, or the use of only very small, simple, blown aerodynamic surfaces on synergistic designs which integrate the lift, drag and control surfaces. The application of these devices to advanced aircraft can offer significant benefits in their performance, efficiency, simplicity, reliability, economic cost of operation, noise reduction, and safety of flight. To further develop and evaluate this potential, this research effort was conducted by GTRI under grant for the NASA Langley Research Center, Applied Aerodynamics Division, Subsonic Aerodynamics Branch, between June 14, 1993 and May 31, 1997.

  9. Using a pneumatic support to correct sitting posture for prolonged periods: a study using airline seats.

    PubMed

    McGill, Stuart M; Fenwick, Chad M J

    2009-09-01

    Prolonged sitting with spine flexion has been linked to low back disorders. A variety of mechanisms account for this based on biomechanical and neurological variables. Airline seats typically cause pronounced lumbar flexion due to their hollowed seat back design. A pneumatic support, placed between the seat back and the lumbar spine, was tested to see if lumbar flexion was reduced. Results showed that when the seats were positioned in the upright position, 15 of 20 participants experienced reduced lumbar flexion (by 15 degrees on average) with the support. The study was repeated on the five non-responders with the seatback set in the reclined position. This resulted in another four experiencing less lumbar flexion. Since seated flexion is associated with disc stress, reducing flexion with the support reduced lumbar stress. Spine flexion that results from prolonged sitting is associated with disc stress and pain. The pneumatic support tested here reduced spine flexion. While it is not known why airline seats are designed with no lumbar support, which causes excessive lumbar flexion while seated, the pneumatic support corrected this deficit. Reclining the seatback enhanced this effect.

  10. The relationship between patency of the maxillary sinus and craniofacial growth in the rabbit.

    PubMed

    Kraut, J M; Kronman, J H

    1988-06-01

    Numerous researchers report the interaction between deviant respiratory patterns (airway obstruction) and craniofacial growth. Many of these studies consisted of cephalometric evaluations of children with enlarged adenoids, obstruction turbinates, or other nasal obstructions. Other experimental studies of the airway's influence on growth include studies that have induced nasal obstruction in animals by plugging the external nares. No investigations were found that examined the role of the paranasal sinuses in craniofacial growth by filling a sinus in growing animals. Furthermore, nothing appears in the literature that considers the paranasal sinuses in the oronasopharyngeal functional matrix theory. The purpose of this study was twofold: (1) to determine the effect of decreasing the pneumatization of the maxillary sinus on ultimate craniofacial growth and development, and (2) to determine the effect on future morphology by obturating a growing sinus. New Zealand white weaning rabbits were used as the experimental animals. Unilateral maxillary sinuses were injected in 18 animals--nine animals were injected on the right side and nine on the left. Eight rabbits served as controls: five received left-side and three right-side sham injections. Dorsal view cephalometric radiographs were taken at (1) the start, (2) at three progress intervals, and (3) at the end of the experiment. Dried skull direct measurements also were performed at the conclusion of the experiment. No statistical significance was found when comparing right and left sides within groups or when comparing any measurement between groups. This demonstrated that filling the maxillary sinuses had no effect on craniofacial growth; the sinuses grew normally in all animals.

  11. [The influence of microwave monochromatic radiation on bone fracture union in rabbits].

    PubMed

    Olchowik, G; Gaweda, R; Blacha, J

    1992-01-01

    The influence of 53.57 GHz microwave radiation of 10mW/cm2 power density on fresh radial bone fracture in 16 rabbits has been investigated. After osteotomy, the occipital area was irradiated one hour daily during two weeks. The development of bony union in experimental and control group (12 rabbits) were compared on the basis of radiographic and physical assessments on the 7-th, 14-th, 21-st and 28-th day after osteotomy. Favourable effect of microwave radiation on bone union was found, especially in the first 14 days after osteotomy. An intense periosteal reaction accompanied the healing process in experimental animals. Biochemical and morphological blood tests run simultaneously were standard.

  12. Damage to the photoreceptor cells of the rabbit retina from 56Fe ions: effect of age at exposure, 1

    NASA Technical Reports Server (NTRS)

    Williams, G. R.; Lett, J. T.; Chatterjee, A. (Principal Investigator)

    1996-01-01

    Optic and proximate tissues of New Zealand white (NZW) rabbits at ages (approximately 3.5 years) near the middle of their median lifespan (5-7 years) were given 0.5-3.5 Gy of 465 MeV u-1 56Fe ions in the Bragg plateau region of energy deposition at a linear energy transfer (LET infinity) of 220 +/- 31 keV micrometer-1. Dose-dependent losses of retinal photoreceptor cells (rods) occurred until 1-2 years after irradiation, the period of this interim report. Similar cumulative losses of photoreceptor cells were seen during the period 1-2 years post-irradiation for rabbits given comparable exposures when young (6-9 weeks old). Since losses of photoreceptor cells at early times had not been determined previously, the current experiment, which was designed to simulate the responses of mature astronauts, redressed that deficiency.

  13. Damage to the photoreceptor cells of the rabbit retina from 56Fe ions: effect of age at exposure, 1.

    PubMed

    Williams, G R; Lett, J T

    1996-01-01

    Optic and proximate tissues of New Zealand white (NZW) rabbits at ages (approximately 3.5 years) near the middle of their median lifespan (5-7 years) were given 0.5-3.5 Gy of 465 MeV u-1 56Fe ions in the Bragg plateau region of energy deposition at a linear energy transfer (LET infinity) of 220 +/- 31 keV micrometer-1. Dose-dependent losses of retinal photoreceptor cells (rods) occurred until 1-2 years after irradiation, the period of this interim report. Similar cumulative losses of photoreceptor cells were seen during the period 1-2 years post-irradiation for rabbits given comparable exposures when young (6-9 weeks old). Since losses of photoreceptor cells at early times had not been determined previously, the current experiment, which was designed to simulate the responses of mature astronauts, redressed that deficiency. PMID:11538988

  14. Immunobiological effect of bitemporal exposure of rabbits to microwaves

    SciTech Connect

    Bogolyubov, V.M.; Pershin, S.B.; Frenkel', I.D.; Sidorov, V.D.; Galenchik, A.I.; Ponomarev, Yu.T.; Bobkova, A.S.; Kuz'min, S.N.; Moshiashvili, I.Ya.; Kozlova, N.N.; Korovkina, E.G.; Agibalov, Yu.V.

    1987-01-01

    The authors investigate the effects of microwave radiation on the immunological behavior of the thyroid and various hormones of rabbits. Irradiation was carried out on the heads of the animals. They were then divided into four groups depending on the period of exposure. The number of hemolysis-forming cells against sheep red blood cells and the concentration of serum immunoglobulins were determined. Levels of TSH, triiodothyronine, thyroxine, testosterone and prostaglandins in serum or blood plasma were determined by radioimmunoassay and the concentration of total 11-hydroxycorticosteroids in the adrenals and plasma were determined by fluorimetry. Microwave radiation of the temporo-parietal region of the head was found to decrease the number of background hemolysis-forming cells. An increase in glucocorticoid function was recorded. Thyroid function was depressed. The plasma 11-hydroxycorticosteroid level was significantly raised. It is concluded in general that microwave irradiation leads to activation of the hypothalamo-hypophyseo-adrenal system with consequent enhancement of the glucocorticoid function of the adrenal cortex and depression of thyroid function.

  15. ORAL PAPILLOMATOSIS OF RABBITS: A VIRUS DISEASE

    PubMed Central

    Parsons, Robert J.; Kidd, John G.

    1943-01-01

    Papillomas occur frequently on the oral mucosa of domestic rabbits procured in the metropolitan area of New York. They are small and benign, and are situated mostly on the under side of the tongue. A filtrable virus can be extracted from them with which growths can be reproduced in the oral mucosa of several species of rabbits and hares but which fails to cause lesions when inoculated into other rabbit tissues and into the oral mucosa of other species. The virus differs notably from the Shope virus, which causes cutaneous papillomas in rabbits but proves innocuous to oral mucosa: rabbits solidly immune to the oral papilloma virus are fully susceptible to the Shope virus and vice versa. The oral papillomas are not highly contagious, for susceptible animals kept in individual cages in the same rooms with others carrying the growths, fed the same kind of food, and cared for by the same attendants, do not "catch" them. They are found much more frequently in the offspring of dams that carry the growths than in those of mothers free from them, and the causative virus can be recovered from the mouth washings of rabbits having no growths. The observations indicate that the virus may be spread by transfer from the mother to the young during the period of suckling, and that it may lie latent in the mouth, doing no harm unless the mucous membrane is injured. The slight trauma occurring now and then when coarse foods are chewed may furnish the required tissue nidus under natural conditions, for papillomas occasionally appear after virus has been dropped into the mouths of uninoculated rabbits; but the more extensive injury and healing resulting from experimental tattoo inoculations proves regularly effective in this respect. Tar can also act as an efficient adjuvant to the virus, the incidence of "spontaneous" oral papillomas being much higher in domestic rabbits that had had the opportunity to lick tar from their ears and paws during long periods than in normal control

  16. Relationship of oxygen dose to angiogenesis induction in irradiated tissue

    SciTech Connect

    Marx, R.E.; Ehler, W.J.; Tayapongsak, P.; Pierce, L.W. )

    1990-11-01

    This study was accomplished in an irradiated rabbit model to assess the angiogenic properties of normobaric oxygen and hyperbaric oxygen as compared with air-breathing controls. Results indicated that normobaric oxygen had no angiogenic properties above normal revascularization of irradiated tissue than did air-breathing controls (p = 0.89). Hyperbaric oxygen demonstrated an eight- to ninefold increased vascular density over both normobaric oxygen and air-breathing controls (p = 0.001). Irradiated tissue develops a hypovascular-hypocellular-hypoxic tissue that does not revascularize spontaneously. Results failed to demonstrate an angiogenic effect of normobaric oxygen. It is suggested that oxygen in this sense is a drug requiring hyperbaric pressures to generate therapeutic effects on chronically hypovascular irradiated tissue.

  17. STUDIES ON RABBIT LYMPHOCYTES IN VITRO

    PubMed Central

    Sell, Stewart; Gell, P. G. H.

    1965-01-01

    Rabbit lymphocytes may be stimulated in vitro with specific antiallotype sera to transform into "blast" cells and to synthesize DNA. This transformation only occurs when the donor cells are obtained from a rabbit having a given γ-globulin allotype (As4) and these cells are cultured in the presence of an antiserum prepared against the given allotype (As4). Heterologous (sheep, goat, and guinea pig) anti-rabbit γ-globulin sera also induce significant blast transformation and DNA synthesis in rabbit lymphocytes. Allotypic transformation and DNA synthesis are due to 7S antiallotype antibodies and do not require complement. The degree of transformation and rate of DNA synthesis is related to the concentration of antibody. Incubation of the appropriate cells with the antiallotype antibody for as short a time as 15 minutes results in a significant degree of "blast" transformation, indicating that the recognition of the antiallotype specificity in the cells and stimulation of the cellular changes leading to eventual transformation is rapid. The activity of the antiallotype sera as measured by transforming or haemagglutinating capacity, may be absorbed by lymphocytes of the appropriate allotype, but is not absorbed by lymphocytes from a donor rabbit not having the allotype to which the antiserum is directed. Transformation does not occur with mixtures of lymphocytes from different rabbits even if 1 donor is immunized against an allotype present in the other donor. Peripheral rabbit lymphocytes can also be induced to undergo "blast transformation" in vitro by phytohaemagglutinin and staphylococcal filtrate. The lack of demonstrable leucoagglutinins in staphylococcal filtrate and antiallotype serum indicates that agglutination is not a necessary prerequisite to the induction of blast transformation. PMID:14316952

  18. Phosphatidylinositol kinase from rabbit reticulocytes

    SciTech Connect

    Tuazon, P.T.; Heng, A.B.W.; Traugh, J.A.

    1986-05-01

    Phosphatidylinositol (PI) kinase was isolated from the postribosomal supernatant of rabbit reticulocytes. This activity was identified by the formation of a product that comigrated with phosphatidylinositol-4-phosphate (PIP) when purified PI was phosphorylated in the presence of (/sup 32/P)ATP and Mg/sup 2 +/. Three major peaks of PI kinase activity were resolved by chromatography on DEAE-cellulose. The first peak eluted at 50-100 mM NaCl together with several serine protein kinases, casein kinase (CK) I and protease activated kinase (PAK) I and II. The PI kinase was subsequently separated from the protein kinases by chromatography on phosphocellulose. The second peak eluted at 125-160 mM NaCl and contained another lipid kinase activity that produced a product which comigrated with phosphatidic acid on thin layer chromatography. The third peak, which eluted at 165-200 mM NaCl, partly comigrated with casein kinase (CK) II and an active protein kinase(s) which phosphorylated mixed histone and histone I. CK II and the histone kinase activities were also separated by chromatography on phosphocelluslose. The different forms of PI kinase were characterized and compared with respect to substrate and salt requirements.

  19. Effects of a Low-Intensity Laser on Dental Implant Osseointegration: Removal Torque and Resonance Frequency Analysis in Rabbits.

    PubMed

    Blay, Alberto; Blay, Claudia C; Tunchel, Samy; Gehrke, Sergio Alexandre; Shibli, Jamil Awad; Groth, Eduardo B; Zezell, Denise M

    2016-08-01

    The objective of this study was to investigate how a low-intensity laser affects the stability and reverse torque resistance of dental implants installed in the tibia of rabbits. Thirty rabbits received 60 dental implants with the same design and surface treatment, one in each proximal metaphysis of the tibia. Three groups were prepared (n = 10 animals each): conventional osseointegration without treatment (control group), surgical sites irradiated with a laser beam emitted in the visible range of 680 nm (Lg1 group), surgical sites irradiated with a laser beam with a wavelength in the infrared range of 830 nm (Lg2 group). Ten irradiation sessions were performed 48 hours apart; the first session was during the immediate postoperative period. Irradiation energy density was 4 J/cm(2) per point in 2 points on each side of the tibias. The resonance frequency and removal torque values were measured at 2 time points after the implantations (3 and 6 weeks). Both laser groups (Lg1 and Lg2) presented a significant difference between resonance frequency analysis values at the baseline and the values obtained after 3 and 6 weeks (P > .05). Although the removal torque values of all groups increased after 6 weeks (P < .05), both laser groups presented greater mean values than those of the control group (P < .01). Photobiomodulation using laser irradiation with wavelengths of 680 and 830 nm had a better degree of bone integration than the control group after 6 weeks of observation time.

  20. [Spontaneous Cryptosporidium infection in weaned rabbits].

    PubMed

    Pavlásek, I; Lávicka, M; Tůmová, E; Skrivan, M

    1996-12-01

    The first occurrence of Cryptosporidium parvum Tyzzer, 1912 in broiler rabbits in the Czech Republic is reported. The protozoon was determined on the basis of morphometrical parameters of oocysts and of localization of endogenous developmental stages. The dynamics of natural Cryptosporidium infection was studied in a group of 72 young rabbits after weaning (their age ranging from 23-33 to 82-92 days) obtained from six large flocks and used in a feeding experiment. C. parvum was found in rabbits from four farms (Tab. I). Animals under observation were divided into 9 subgroups according to the genotype (Hyla 2000, California White, crosses of New Zealand x California, New Zealand White, Cunistar and Zika) as well as according to the farm of origin. The animals were housed in 28 cages under the conditions of two-floor cage technology. The upper floor consisted of cages housing three head, the lower floor two head each. The animals were fed ad libitum with commercial feed mixture (till the average age of 64.days supplemented with Robenidin as coccidiostat). During the first 10 days of observation pooled samples of droppings from each cage were examinated by flotation-centrifugation method according to Breza (1957) and Pavlásek (1991) in the intervals of three to four days, later one-week intervals. Post mortem scrapings from mucous epithelium taken from young rabbits were examinated (to reveal endogenous developmental stages of C. parvum) together with digesta (to detect oocysts of the protozoon) taken from the full length of the small intestine using method of native preparations and Giemsa stain. In one 37-day dead animal the small and large intestines were examined histologically. The maximum number of young rabbits infected with C. parvum were 30-40 and 33-43 days old (Fig. 1). In animals of this age category the oocysts of the protozoon were found in pooled samples in 11 and 12 cages (39.3 and 42.9%) from totally 28 cages under study. In rabbits of more than 50

  1. Effects of pulsed Nd:YAG laser on the surface of rabbit retina

    SciTech Connect

    Fleck, B.W.; Chew, P.T.; Lim, A.S.; Tock, E.P. )

    1991-03-01

    Six albino rabbits were subjected to pulsed Nd:YAG laser irradiation to the retinal surface to determine whether such treatment would lead to proliferative vitreoretinopathy. Choroidal, retinal, and preretinal hemorrhages, noted at the time of treatment, resolved after 7 to 10 days. Histological examination showed no signs of anterior segment damage or proliferative vitreoretinopathy. These preliminary findings suggest that more extensive experimentation is warranted to determine if pulsed Nd:YAG laser may in fact safely be used to separate vitreoretinal adhesions in the treatment of retinal detachment.

  2. Functional domains of rabbit thrombomodulin.

    PubMed

    Bourin, M C; Boffa, M C; Björk, I; Lindahl, U

    1986-08-01

    Thrombomodulin isolated from rabbit lung was separated by ion-exchange chromatography on DEAE-cellulose into a retarded (acidic) and a nonretarded (nonacidic) fraction. Both fractions contained the cofactor required for the activation of protein C. In addition, the acidic fraction (but not the nonacidic fraction) prevented the clotting of fibrinogen by thrombin ("direct" anticoagulant activity) and accelerated the inhibition of thrombin by antithrombin (effect corresponding to 2-10 international units of heparin per mg of protein). Both of these activities were readily neutralized by the synthetic polycation Polybrene, which did not appreciably affect protein C activation. They were also eliminated by digestion of thrombomodulin with bacterial heparinase, which, in addition, converted the acidic form of the protein C activation cofactor to a nonacidic form. Similar conversion observed during storage of thrombomodulin was attributed to endogenous proteinase activity. Density-gradient centrifugation of the acidic form of thrombomodulin in CsCl/4M guanidinium chloride failed to separate either of the direct or antithrombin-dependent anticoagulant activities from the protein C activation cofactor, which showed a buoyant density of 1.31-1.34 g/ml. The nonacidic cofactor had a lower density, 1.26-1.28 g/ml. Unreduced thrombomodulin yielded two major fractions of protein C activation cofactor on NaDodSO4/PAGE, with apparent Mr of approximately 68,000 and 57,000, respectively. The larger component contained essentially all of the direct and antithrombin-dependent anticoagulant activities. We propose that these activities as well as the negative charge and the higher buoyant density of the acidic, Mr 68,000 form of thrombomodulin are due to a heparin-like polysaccharide and, further, that this component can be separated from the major portion of the molecule, which contains the protein C activation site, through the action of a proteinase.

  3. Computer simulation of the pneumatic separator in the pneumatic-electrostatic separation system for recycling waste printed circuit boards with electronic components.

    PubMed

    Xue, Mianqiang; Xu, Zhenming

    2013-05-01

    Technologies could be integrated in different ways into automatic recycling lines for a certain kind of electronic waste according to practical requirements. In this study, a new kind of pneumatic separator with openings at the dust hooper was applied combing with electrostatic separation for recycling waste printed circuit boards. However, the flow pattern and the particles' movement behavior could not be obtained by experimental methods. To better control the separation quantity and the material size distribution, computational fluid dynamics was used to model the new pneumatic separator giving a detailed understanding of the mechanisms. Simulated results showed that the tangential velocity direction reversed with a relatively small value. Axial velocity exhibited two sharp decreases at the x axis. It is indicated that the bottom openings at the dust hopper resulted in an enormous change in the velocity profile. A new phenomenon that was named dusting was observed, which would mitigate the effect of particles with small diameter on the following electrostatic separation and avoid materials plugging caused by the waste printed circuit boards special properties effectively. The trapped materials were divided into seven grades. Experimental results showed that the mass fraction of grade 5, grade 6, and grade 7 materials were 27.54%, 15.23%, and 17.38%, respectively. Grade 1 particles' mass fraction was reduced by 80.30% compared with a traditional separator. Furthermore, the monocrystalline silicon content in silicon element in particles with a diameter of -0.091 mm was 18.9%, higher than that in the mixed materials. This study could serve as guidance for the future material flow control, automation control, waste recycling, and semiconductor storage medium destruction.

  4. Selective ablation of WHHLMI rabbit atherosclerotic plaque by quantum cascade laser in the 5.7 μm wavelength range for less-invasive laser angioplasty

    NASA Astrophysics Data System (ADS)

    Hashimura, Keisuke; Ishii, Katsunori; Akikusa, Naota; Edamura, Tadataka; Yoshida, Harumasa; Awazu, Kunio

    2013-06-01

    We investigated the potential of a compact and high-power quantum cascade laser (QCL) in the 5.7 μm wavelength range for less-invasive laser angioplasty. Atherosclerotic plaques consist mainly of cholesteryl esters. Radiation at a wavelength of 5.75 μm is strongly absorbed in C=O stretching vibration mode of cholesteryl esters. Our previous study achieved to make cutting differences between a normal artery and an atherosclerotic lesions using nanosecond pulsed laser by difference-frequency generation (DFG laser) at the wavelength of 5.75 μm. For applying this technique to clinical treatment, a compact laser device is required. In this study, QCL irradiation effects to a porcine normal aorta were compared with DFG laser. Subsequently, QCL irradiation effects on an atherosclerotic aorta of myocardial infarction-prone Watanabe heritable hyperlipidemic rabbit (WHHLMI rabbit) and a normal rabbit aorta were observed. As a result, the QCL could make cutting differences between the rabbit atherosclerotic and normal aortas. On the other hand, the QCL induced more thermal damage to porcine normal aorta than the DFG laser at the irradiation condition of comparable ablation depths. In conclusion, the possibility of less-invasive and selective treatment of atherosclerotic plaques using the QCL in the 5.7 μm wavelength range was revealed, although improvement of QCL was required to prevent the thermal damage of a normal artery.

  5. Light stimulation of iris tyrosinase in vivo. [Rabbits

    SciTech Connect

    Dryja, T.P.; Kimball, G.P.; Albert, D.M.

    1980-05-01

    This paper presents evidence that light stimulates tyrosinase activity in iris melanocytes in rabbits. Levels of iris tyrosinase were found to be greater in eyes of rabbits exposed to light for 6 weeks than in eyes of rabbits maintained in darkness. Despite increasing tyrosinase levels, exposure to light produced no clinically observable change in iris color.

  6. Rabbits and hominin survival in Iberia.

    PubMed

    Fa, John E; Stewart, John R; Lloveras, Lluís; Vargas, J Mario

    2013-04-01

    High dependence on the hunting and consumption of large mammals by some hominins may have limited their survival once their preferred quarry became scarce or disappeared. Adaptation to smaller residual prey would have been essential after the many large-bodied species decreased in numbers. We focus on the use of a superabundant species, the rabbit, to demonstrate the importance of this taxon in Iberia as fundamental to predators. We show that the use of the rabbit over time has increased, and that there could have been differential consumption by Neanderthals and Anatomically Modern Humans (AMH). Analysis of bone remains from excavations throughout Iberia show that this lagomorph was a crucial part of the diet of AMH but was relatively unutilised during the Mousterian, when Neanderthals were present. We first present changes in mammalian biomass and mean body mass of mammals over 50,000 years, to illustrate the dramatic loss of large mammalian fauna and to show how the rabbit may have contributed a consistently high proportion of the available game biomass throughout that period. Unlike the Italian Peninsula and other parts of Europe, in Iberia the rabbit has provided a food resource of great importance for predators including hominins. We suggest that hunters that could shift focus to rabbits and other smaller residual fauna, once larger-bodied species decreased in numbers, would have been able to persist. From the evidence presented here, we postulate that Neanderthals may have been less capable of prey-shifting and hence use the high-biomass prey resource provided by the rabbit, to the extent AMH did.

  7. [Acute toxoplasmosis outbreak in rabbit flocks].

    PubMed

    Bergmann, V; Heidrich, R; Kiupel, H

    1980-02-01

    Acute toxoplasmosis occurred in 2-18 month old domestic rabbits of 15 flocks entailing losses of 3-66%. Pathomorphological examinations of 49 rabbits revealed lesions of a generalized granulomatous-necrotizing toxoplasmosis with spleen, liver, lungs and lymphonodes mainly affected. Similarities existed to pseudotuberculosis. The spleen was massively packed with pseudocysts and cysts of Toxoplasma. Electronmicroscopic examinations of organ specimens fixed in formalin assured the identity of Toxoplasma and serological tests (CFT, SFT, IFAT) as well as the mouse test confirmed it.

  8. Plasma PIVKA proteins in rabbits given warfarin.

    PubMed

    Zivelin, A; Rao, L V; Rapaport, S I

    1996-06-01

    The presence of partially carboxylated forms of the vitamin K dependent coagulation factors (PIVKA) was evaluated in the plasma of rabbits treated with warfarin. Excess antigen over activity as measured in rabbit specific assays was taken as evidence for PIVKA. Our data confirm a previous report of the absence of plasma PIVKA prothrombin. In contrast, plasma PIVKA factors VII, IX, and X were demonstrable. A striking excess of plasma factor IX antigen over activity was measured and a large fraction of the factor IX antigen persisted in the plasma after its adsorption with barium citrate.

  9. Pneumatic testing in 45-degree-inclined boreholes in ash-flow tuff near Superior, Arizona

    USGS Publications Warehouse

    LeCain, G.D.

    1995-01-01

    Matrix permeability values determined by single-hole pneumatic testing in nonfractured ash-flow tuff ranged from 5.1 to 20.3 * 1046 m2 (meters squared), depending on the gas-injection rate and analysis method used. Results from the single-hole tests showed several significant correlations between permeability and injection rate and between permeability and test order. Fracture permeability values determined by cross-hole pneumatic testing in fractured ash-flow tuff ranged from 0.81 to 3.49 * 1044 m2, depending on injection rate and analysis method used. Results from the cross-hole tests monitor intervals showed no significant correlation between permeability and injection rate; however, results from the injection interval showed a significant correlation between injection rate and permeability. Porosity estimates from the 'cross-hole testing range from 0.8 to 2.0 percent. The maximum temperature change associated with the pneumatic testing was 1.2'(2 measured in the injection interval during cross-hole testing. The maximum temperature change in the guard and monitor intervals was O.Ip C. The maximum error introduced into the permeability values due to temperature fluctuations is approximately 4 percent. Data from temperature monitoring in the borehole indicated a positive correlation between the temperature decrease in the injection interval during recovery testing and the gas-injection rate. The thermocouple psychrometers indicated that water vapor was condensing in the boreholes during testing. The psychrometers in the guard and monitor intervals detected the drier injected gas as an increase in the dry bulb reading. The relative humidity in the test intervals was always higher than the upper measurement limit of the psychrometers. Although the installation of the packer system may have altered the water balance of the borehole, the gas-injection testing resulted in minimal or no changes in the borehole relative humidity.

  10. A three-barrel repeating pneumatic pellet injector for plasma fueling of the Joint European Torus

    SciTech Connect

    Combs, S.K.; Milora, S.L.; Baylor, L.R.; Foust, C.R.; Gethers, F.E.; Sparks, D.O.

    1987-01-01

    Pellet fueling, the injection of frozen hydrogen isotope pellets at high velocity, has been used to improve plasma performance in various tokamak experiments. In one recent experiment, the repeating pneumatic hydrogen pellet injector was used on the Tokamak Fusion Test Reactor (TFTR). This machine gun-like device, which was developed at the Oak Ridge National Laboratory (ORNL) with an objective of steady-state fueling applications, was characterized by a fixed pellet size and a maximum repetition rate of 4 to 6 Hz for several seconds. It was used to deliver deuterium pellets at speeds ranging from 1.0 to 1.5 km/s into TFTR plasma discharges. In the first experiments, injection of single, large (nominal 4-mm-diam) pellets provided high plasma densities in TFTR (1.8 x 10/sup 14/ cm/sup -3/ on axis). After a conversion to smaller (nominal 2.7-mm-diam) pellets, the pellet injector was operated in the repeating mode to gradually increase the plasma density, injecting up to five pellets on a single machine pulse. This resulted in central plasma densities approaching 4 x 10/sup 14/ cm/sup -3/ and n tau values of 1.4 x 10/sup 14/ cm/sup -3/s. For plasma fueling applications on the Joint European Torus (JET), a pellet injector fashioned after the prototype repeating pneumatic design has been developed. The versatile injector features three repeating guns in a common vacuum enclosure; the guns provide pellets that are 2.7, 4.0, and 6.0 mm in diameter and can operate independently at repetition rates of 5, 2.5, and 1 Hz, respectively. The injector has been installed on JET. A description of the equipment is presented, emphasizing the differences from the original repeating device. Performance characteristics of the three pneumatic guns are also included.

  11. The use of pneumatically generated water pressure signals for aquifer characterization

    NASA Astrophysics Data System (ADS)

    Fort, M.; Roberts, R.; Chace, D.

    2013-12-01

    The use of pneumatically generated pressure signals for aquifer characterization Hydraulic tests are the most reliable method of obtaining estimates of hydrologic properties, such as conductivity, that are essential for flow and transport modeling. The use of a sinusoidal signal for hydraulic testing is well established, with Streltsova (1988), Rasmussen (2003) and others having developed analytic solutions. Sinusoidal tests provide a unique easily distinguished signal that reduces ambiguity during analysis and we show that a sinusoidal pressure signal propagates farther into the formation than a standard slug-test signal. If a sinusoidal test is combined with a slug and/or a constant rate test, it can further reduce uncertainty in the estimated parameter values. We demonstrate how pneumatic pressure can be used to generate all three of these signals. By positioning pressure transducers both below the water level and in the head space above the water, we can monitor the total pressure acting on the formation and the changes in water level. From the changes in water level, it is possible to calculate the flow rate in and out of the well, assuming that the well diameter and water density are known. Using gas flow controllers with a Supervisory Control And Data Acquisition (SCADA) system we are able to precisely control the pressures in the well. The use of pneumatic pressure has the advantage that it requires less equipment (no pumps) and produces no water. We also show how the numerical well test analysis program nSIGHTS can be used to analyze all three types of tests simultaneously and to assess the relative contribution of each type of test to the parameter estimation. nSIGHTS was recently released as open source by Sandia National Laboratories and is available for free.

  12. Comparison of high-resolution wax-embedded and pneumatically coupled borehole seismic detectors

    SciTech Connect

    Owen, T.E.; Parra, J.O. )

    1993-01-01

    High quality seismic measurements at frequencies up to about 2,000 Hz are needed if projected resolution limits on the order of 1m in spatial dimension are to be realized in reservoir structure delineation, cross-well sonic logging, and shallow reverse VSP applications. While sources and detectors are critical to this goal, the authors have investigated detector requirements in an objective way to demonstrate a successful design philosophy capable of achieving unprecedented wide-band frequency response and data quality in three-component shallow-borehole sensors. Two prototype detectors were developed: a nearly ideal responding wax-embedded reference'' detector and a pneumatically coupled detector exhibiting closely comparable performance. Their approach uses a three-axis accelerometer sensor assembly installed in a borehole drilled through the weathered surface to a depth at which the ground is competent enough to support practical kilohertz wave propagation. The wax-coupled detector is planted using a meltable wax embedment to achieve a rigid, stress-free, conformal coupling at the bottom of the hole. Experimental test results show this wax-embedded detector to have excellent broadband three-component response at frequencies up to 2,500 Hz; a range heretofore unexplored for seismic applications. The pneumatically coupled detector, although limited by modal resonance distortion effects in the highest range of frequencies, demonstrated useful three-component response at frequencies up to 1,500 Hz. Tests of the two coupling techniques under identical conditions illustrate their high-quality responses and their differences. Field tests of the prototype pneumatically coupled detector in shallow reverse vertical seismic profiling (VSP) measurements demonstrate the practical effectiveness of the basic high-resolution probe design concepts.

  13. Hydrodynamic injection with pneumatic valving for microchip electrophoresis with total analyte utilization

    SciTech Connect

    Sun, Xuefei; Kelly, Ryan T.; Danielson, William F.; Agrawal, Nitin; Tang, Keqi; Smith, Richard D.

    2011-04-26

    A novel hydrodynamic injector that is directly controlled by a pneumatic valve has been developed for reproducible microchip capillary electrophoresis (CE) separations. The poly(dimethylsiloxane) (PDMS) devices used for evaluation comprise a separation channel, a side channel for sample introduction, and a pneumatic valve aligned at the intersection of the channels. A low pressure (≤ 3 psi) applied to the sample reservoir is sufficient to drive sample into the separation channel. The rapidly actuated pneumatic valve enables injection of discrete sample plugs as small as ~100 pL for CE separation. The injection volume can be easily controlled by adjusting the intersection geometry, the solution back pressure and the valve actuation time. Sample injection could be reliably operated at different frequencies (< 0.1 Hz to >2 Hz) with good reproducibility (peak height relative standard deviation ≤ 3.6%) and no sampling biases associated with the conventional electrokinetic injections. The separation channel was dynamically coated with a cationic polymer, and FITC-labeled amino acids were employed to evaluate the CE separation. Highly efficient (≥ 7.0 × 103 theoretical plates for the ~2.4 cm long channel) and reproducible CE separations were obtained. The demonstrated method has numerous advantages compared with the conventional techniques, including repeatable and unbiased injections, no sample waste, high duty cycle, controllable injected sample volume, and fewer electrodes with no need for voltage switching. The prospects of implementing this injection method for coupling multidimensional separations, for multiplexing CE separations and for sample-limited bioanalyses are discussed.

  14. Development of hybrid type pneumatic vibration isolation table by piezo-stack actuator and filtered-X LMS algorithm

    NASA Astrophysics Data System (ADS)

    Shin, Yun-ho; Jang, Dong-doo; Moon, Seok-jun; Jung, Hyung-Jo; Moon, Yeong-jong; Song, Chang-kyu

    2011-04-01

    Recently, vibration requirements are getting stricter as precise equipments need more improved vibration environment to realize their powerful performance. Though the passive pneumatic vibration isolation tables are frequently used to satisfy the rigorous vibration requirements, the specific vibration problem, especially continuous sinusoidal or periodic vibration induced by a rotor system of other precise equipment, a thermo-hygrostat or a ventilation system, is still left. In this research, the application procedure of Filtered-X LMS algorithm to pneumatic vibration isolation table with piezo-stack actuators is proposed to enhance the isolation performance for the continuous sinusoidal or periodic vibration. In addition, the experimental results to show the isolation performance of proposed system are also presented together with the isolation performance of passive pneumatic isolation table.

  15. A Simplified Method to Fabricate a Pneumatic Ocular Prosthesis for Large Ocular Defects.

    PubMed

    Aggarwal, Himanshi; Kumar, Pradeep; Singh, Raghuwar Dayal

    2014-12-01

    When an enucleation or exenteration procedure removes the entire orbital contents but not the eyelids, an abnormally large orbital socket is created that would require an equally sized volume enhancing, flush fitting ocular prosthesis. The solid acrylic prosthesis would rest on or in the lower fornix and owing to its weight, causes distortion of the lower eyelid and/or asymmetrical alignment of the entire palpebral fissure. The aim of this article was to describe a method of fabricating a pneumatic light weight custom ocular prosthesis using lost wax technique to overcome the deteriorating effects of conventional solid ocular prosthesis. PMID:26199499

  16. Ultrasonic detection of solid phase mass flow ratio of pneumatic conveying fly ash

    NASA Astrophysics Data System (ADS)

    Duan, Guang Bin; Pan, Hong Li; Wang, Yong; Liu, Zong Ming

    2014-04-01

    In this paper, ultrasonic attenuation detection and weight balance are adopted to evaluate the solid mass ratio in this paper. Fly ash is transported on the up extraction fluidization pneumatic conveying workbench. In the ultrasonic test. McClements model and Bouguer-Lambert-Beer law model were applied to formulate the ultrasonic attenuation properties of gas-solid flow, which can give the solid mass ratio. While in the method of weigh balance, the averaged mass addition per second can reveal the solids mass flow ratio. By contrast these two solid phase mass ratio detection methods, we can know, the relative error is less.

  17. Wearable air supply for pneumatic artificial hearts and ventricular assist devices.

    PubMed

    Sipin, A J; Fabrey, W J; Smith, S H; Doussourd, J D; Olsen, D B

    1992-08-01

    An experimental wearable air supply for pneumatic artificial hearts and ventricular assist devices has been built and tested. The unit eliminates the need for tethering to a large, stationery driver. The miniaturized air supply is designed for ambulatory patients with implanted pulsatile pneumatic total artificial hearts (TAH) or pneumatic left-ventricular assist devices (LVAD), to permit mobility in clinical and home settings. The device has major short-term utility as a supply for pneumatic TAH or VAD bridges in patients awaiting heart transplants. The system design for the wearable driver includes a novel, fast rotary compressor, driven by a brushless direct current (DC) motor to supply air to the ventricle through an electromagnetically actuated directional valve, all controlled by a microcomputer. Stroke volume from 0 to 200 cc; pulse rate from 60 to 160 bpm, and duty cycle from 33% to 50% are selected on a keyboard, and the selected or measured parameters can be shown on a liquid crystal display. For control of delivery from a single ventricular assist device, stroke volume is controlled by variation of compressor speed. In the wearable air supply for a TAH, a single compressor drives both ventricles alternately through a double-acting directional valve. Air volume delivered to the left ventricle is adjusted by variation of compressor speed, and air volume to the right ventricle by variation of ejection time. The effect on blood flow rate of the lower impedance to the right ventricle is compensated by provision of a two-stage compressor, in which a single stage drives the right ventricle, and both stages connected in parallel drive the left ventricle. The overall dimensions of the prototype air supply for driving either a TAH or LVAD are 4.5 by 7.8 by 4.5 inches, including an emergency battery with a duration of 15 to 30 min depending on load. The weight is presently 5.5 lb, but this will be reduced in a production design and for a dedicated LVAD air supply

  18. Effect of Oxygen Concentration on Autogenous Ignition Temperature and Pneumatic Impact Ignitability of Nonmetallic Materials

    NASA Technical Reports Server (NTRS)

    Smith, Sarah

    2009-01-01

    Extensive test data exist on the ignitability of nonmetallic materials in pure oxygen, but these characteristics are not as well understood for lesser oxygen concentrations. In this study, autogenous ignition temperature testing and pneumatic impact testing were used to better understand the effects of oxygen concentration on ignition of nonmetallic materials. Tests were performed using oxygen concentrations of 21, 34, 45, and 100 %. The following materials were tested: PTFE Teflon(Registered Trademark), Buna-N, Silicone, Zytel(Registered Trademark) 42, Viton(registered Trademark) A, and Vespel(Registered Trademark) SP-21.

  19. Liquid Hydrogen Regulated Low Pressure High Flow Pneumatic Panel AFT Arrow Analysis

    NASA Technical Reports Server (NTRS)

    Jones, Kelley, M.

    2013-01-01

    Project Definition: Design a high flow pneumatic regulation panel to be used with helium and hydrogen. The panel will have two circuits, one for gaseous helium (GHe) supplied from the GHe Movable Storage Units (MSUs) and one for gaseous hydrogen (GH2) supplied from an existing GH2 Fill Panel. The helium will supply three legs; to existing panels and on the higher pressure leg and Simulated Flight Tanks (SFTs) for the lower pressure legs. The hydrogen line will pressurize a 33,000 gallon vacuum jacketed vessel.

  20. Characterization and Prediction of Subsurface Pneumatic PressureVariations at Yucca Mountain, Nevada

    SciTech Connect

    Ahlers, C. Fredrik; Finsterle, Stefan; Bodvarsson, Gudmundur S.

    1998-01-02

    Yucca Mountain, Nevada is being investigated as the proposed site for geologic disposal of high level nuclear waste. A massive data collection effort for characterization of the unsaturated zone is being carried out at the site. The USGS is monitoring the subsurface pressure variations due to barometric pumping in several boreholes. Numerical models are used to simulate the observed subsurface pressure variations. Data inversion is used to characterize the unsaturated system and estimate the pneumatic diffusivity of important geologic features. Blind predictions of subsurface response and subsequent comparison to recorded data have built confidence in the models of Yucca Mountain.

  1. Depressed scar after filler injection successfully treated with pneumatic needleless injector and radiofrequency device.

    PubMed

    Seok, Joon; Choi, Sun Young; Park, Kui Young; Jang, Ji Hye; Bae, Joon Ho; Kim, Beom Joon; Kim, Myeung Nam; Hong, Chang Kwon

    2016-01-01

    Fillers are known to be associated with a number of side effects, one of the most severe being skin necrosis. The most vulnerable areas are those that are supplied by a single arterial branch; for example, the glabellar and nasolabial folds are susceptible. In this study, we report good cosmetic outcomes were produced by utilizing the pneumatic needleless injector and radiofrequency device to treat depressed scars that occurred after necrosis following filler injection. Initially, applying light-emitting diode treatment and following through with the two devices appears to have synergistic effects for scar remodeling when dealing with treatment of depressed scars with irregular borders.

  2. Postcranial skeletal pneumaticity and air-sacs in the earliest pterosaurs

    PubMed Central

    Butler, Richard J.; Barrett, Paul M.; Gower, David J.

    2009-01-01

    Patterns of postcranial skeletal pneumatization (PSP) indicate that pterosaurs possessed components of a bird-like respiratory system, including a series of ventilatory air-sacs. However, the presence of PSP in the oldest known pterosaurs has not been unambiguously demonstrated by previous studies. Here we provide the first unequivocal documentation of PSP in Late Triassic and earliest Jurassic pterosaurs. This demonstrates that PSP and, by inference, air-sacs were probably present in the common ancestor of almost all known pterosaurs, and has broader implications for the evolution of respiratory systems in bird-line archosaurs, including dinosaurs. PMID:19411265

  3. Active control of crossflow-induced transition by means of in-line pneumatic actuator orifices

    NASA Astrophysics Data System (ADS)

    Lohse, J.; Barth, H. P.; Nitsche, W.

    2016-08-01

    The possibility of a pneumatic actuator system for controlling the crossflow vortex-induced laminar breakdown is investigated by means of hot-wire measurements. Steady blowing or suction through a spanwise row of periodically arranged orifices initiates a system of longitudinal vortices which reduces the amplitude of the most amplified stationary crossflow vortices. Thus, the onset of high-frequency secondary instability and the following laminar-turbulent transition was shifted farther downstream. All experiments were conducted at the redesigned DLR swept flat plate experiment in the open test section of the 1 m wind tunnel at the DLR in Göttingen.

  4. Pneumatism in Seneca: an example of interaction between physics and medicine.

    PubMed

    Le Blay, Frédéric

    2014-01-01

    The reading of Seneca's works is of the greatest interest for the history of ancient medicine since this Stoic philosopher makes extensive use of medical comparisons and references with regard to ethics and epistemology. Seneca should therefore be considered as an indirect but important witness to the tracing of medical doxography. The study of his Problems in Nature (Naturales Quaestiones), as they are based on a pneumatical etiological system, shows the complexity of the relationship between medical and philosophical schools. It also brings new light on some of the treatises from the Hippocratic Corpus.

  5. Antiradiation Vaccine: Technology Development Of Prophylaxis, Prevention And Treatment Of Biological Consequences And Complications After Neutron Irradiation.

    NASA Astrophysics Data System (ADS)

    Popov, Dmitri; Maliev, Slava; Jones, Jeffrey

    irradiation generated in a canal of Research Reactor BBP-M and BBP-M. Mixed neutron beam contained 95% of fast neutron irradiation and 5% of gamma-irradiation. Neutron energy - 1.98 - 2.30 Me V energy. Dose - 10.7 Gy., 0.22 Gy-min. Scheme of experiments: Rabbits from all groups were irradiated in a canal of Research Reactor together. Group A: control-5 rabbits; Group B:placebo-5 rabbits; Group C: radioprotectant Cystamine (50 mg-kg)-5 rabbits, 15 minutes before irradiation Group D:Radio-protectant Mexamine (10 mg-kg)-5 rabbits { 15 minutes before irradiation; Group E: Antiradiation Vaccine: subcutaneus administration or I-M - 2 ml of active substance , 20 days before irradiation. Results: Control Group A - 100% mortality within the next two hours after neutron irradiation with clinical symptoms of acute cerebrovascular syndrome. Group B - 100% mortality less than two hours following irradiation. Group C - 100% mortality within 8-10 hours after irradiation. Group D - 100% mortality within 8-11 hours after irradiation. In Groups A - D the development of extremely severe form of Acute Radiation Cerebrovascular Syndrome produced rapid death. Group E - 100% mortality within 240 hours ( 9|10 days) following neutron irradiation with animals exhibiting cardiovascular, cerebrovascular and gastrointestinal clinical symptoms. Discussion: A pre-irradiation vaccination with Antiradiation Vaccine is effective against mild and even high doses of neutron radiation. Vaccination with antiradiation Vaccine prolonged survival time of rabbits, exposed to a high dose LD100, of neutron radiation: from two hours (control) up to 11 days. We also postulate that radiation toxins,isolated from lymph of gamma-irradiated animals are likely similar to structure of radiation toxins circulated in blood and lymph of neutron irradiated animals. Toxico-kinetics and toxico-dynamics of radiation toxins of after neutron-irradiation were quite unique and distinguished from different types of radiation

  6. Cloning, Characteristics, and Functional Analysis of Rabbit NADPH Oxidase 5

    PubMed Central

    Chen, Feng; Yin, Caiyong; Dimitropoulou, Christiana; Fulton, David J. R.

    2016-01-01

    Background: Nox5 was the last member of the Nox enzyme family to be identified. Functionally distinct from the other Nox isoforms, our understanding of its physiological significance has been hampered by the absence of Nox5 in mouse and rat genomes. Nox5 is present in the genomes of other species such as the rabbit that have broad utility as models of cardiovascular disease. However, the mRNA sequence, characteristics, and functional analysis of rabbit Nox5 has not been fully defined and were the goals of the current study. Methods: Rabbit Nox5 was amplified from rabbit tissue, cloned, and sequenced. COS-7 cells were employed for expression and functional analysis via Western blotting and measurements of superoxide. We designed and synthesized miRNAs selectively targeting rabbit Nox5. The nucleotide and amino acid sequences of rabbit Nox5 were aligned with those of putative rabbit isoforms (X1, X2, X3, and X4). A phylogenetic tree was generated based on the mRNA sequence for Nox5 from rabbit and other species. Results: Sequence alignment revealed that the identified rabbit Nox5 was highly conserved with the predicted sequence of rabbit Nox5. Cell based experiments reveal that rabbit Nox5 was robustly expressed and produced superoxide at rest and in a calcium and PMA-dependent manner that was susceptible to superoxide dismutase and the flavoprotein inhibitor, DPI. miRNA-1 was shown to be most effective in down-regulating the expression of rabbit Nox5. Phylogenetic analysis revealed a close relationship between rabbit and armadillo Nox5. Rabbit Nox5 was relatively closely related to human Nox5, but lies in a distinct cluster. Conclusion: Our study establishes the suitability of the rabbit as a model organism to further our understanding of the role of Nox5 in cardiovascular and other diseases and provides new information on the genetic relationship of Nox5 genes in different species. PMID:27486403

  7. Development of X-Y Servo Pneumatic-Piezoelectric Hybrid Actuators for Position Control with High Response, Large Stroke and Nanometer Accuracy

    PubMed Central

    Chiang, Mao-Hsiung

    2010-01-01

    This study aims to develop a X-Y dual-axial intelligent servo pneumatic-piezoelectric hybrid actuator for position control with high response, large stroke (250 mm, 200 mm) and nanometer accuracy (20 nm). In each axis, the rodless pneumatic actuator serves to position in coarse stroke and the piezoelectric actuator compensates in fine stroke. Thus, the overall control systems of the single axis become a dual-input single-output (DISO) system. Although the rodless pneumatic actuator has relatively larger friction force, it has the advantage of mechanism for multi-axial development. Thus, the X-Y dual-axial positioning system is developed based on the servo pneumatic-piezoelectric hybrid actuator. In addition, the decoupling self-organizing fuzzy sliding mode control is developed as the intelligent control strategies. Finally, the proposed novel intelligent X-Y dual-axial servo pneumatic-piezoelectric hybrid actuators are implemented and verified experimentally. PMID:22319266

  8. Rabbit haemorrhagic disease: advantages of cELISA in assessing immunity in wild rabbits (Oryctolagus cuniculus).

    PubMed

    Zheng, Tao; Parkes, John P

    2011-12-15

    Rabbit haemorrhagic disease (RHD) is an acute fatal disease of domestic and wild European rabbits (Oryctolagus cuniculus) caused by RHD virus (RHDV). Accurate assessment of immunity is of great importance for the conservation and control of wild rabbits. We evaluated a competitive ELISA (cELISA) against isotype ELISAs for assessing the protective immunity against the disease by challenging 50 wild-caught rabbits with a lethal dose of RHDV. Death or survival to the challenge was used as a criterion to determine the performance characteristics of the assay for the assessment of immunity in rabbits. At 1:10 dilution, a serum exhibiting ≥ 25% inhibition (1:10(25)) was regarded as the presence of RHDV-specific antibodies. Eleven of 16 (68.8%) rabbits with antibodies at 1:10(25) (<1:40) died of RHD. When the cut-off was moved from 25% to 50% inhibition (1:10(50)) at 1:10 serum dilution, the assay sensitivity, specificity and accuracy for the protective immunity were improved from 84%, 54.2% and 69.4% to 84%, 100% and 91.8%, respectively. We also demonstrated at the epitope amino acid sequence level why the presence of the RHDV-cross reactive benign rabbit calicivirus, which interfered with isotype ELISAs, had little impact on the specificity of the cELISA for the diagnosis of RHDV infection. The presence of RHDV-specific antibody at 1:10(50) by the cELISA is a reliable indicator for the protective immunity. In contrast to isotype ELISAs, the cELISA is a valuable specific tool for monitoring the herd immunity to RHD for the conservation and management of wild rabbits in the field.

  9. An individual-based model of rabbit viral haemorrhagic disease on European wild rabbits (Oryctolagus cuniculus)

    USGS Publications Warehouse

    Fa, John E.; Sharples, Colin M.; Bell, Diana J.; DeAngelis, Donald L.

    2001-01-01

    We developed an individual-based model of Rabbit Viral Hemorrhagic Disease (RVHD) for European wild rabbits (Oryctolagus cuniculus L.), representing up to 1000 rabbits in four hectares. Model output for productivity and recruitment matched published values. The disease was density-dependent and virulence affected outcome. Strains that caused death after several days produced greater overall mortality than strains in which rabbits either died or recovered very quickly. Disease effect also depended on time of year. We also elaborated a larger scale model representing 25 km2 and 100,000+ rabbits, split into a number of grid-squares. This was a more traditional model that did not represent individual rabbits, but employed a system of dynamic equations for each grid-square. Disease spread depended on probability of transmission between neighboring grid-squares. Potential recovery from a major population crash caused by the disease relied on disease virulence and frequency of recurrence. The model's dependence on probability of disease transmission between grid-squares suggests the way that the model represents the spatial distribution of the population affects simulation. Although data on RVHD in Europe are lacking, our models provide a basis for describing the disease in realistic detail and for assessing influence of various social and spatial factors on spread.

  10. The rod circuit in the rabbit retina.

    PubMed

    Vaney, D I; Young, H M; Gynther, I C

    1991-01-01

    Mammalian retinae have a well-defined neuronal pathway that serves rod vision. In rabbit retina, the different populations of interneurons in the rod pathway can be selectively labeled, either separately or in combination. The rod bipolar cells show protein kinase C immunoreactivity; the rod (AII) amacrine cells can be distinguished in nuclear-yellow labeled retina; the rod reciprocal (S1 & S2) amacrine cells accumulate serotonin; and the dopaminergic amacrine cells show tyrosine-hydroxylase immunoreactivity. Furthermore, intracellular dye injection of the microscopically identified interneurons enables whole-population and single-cell studies to be combined in the same tissue. Using this approach, we have been able to analyze systematically the neuronal architecture of the rod circuit across the rabbit retina and compare its organization with that of the rod circuit in central cat retina. In rabbit retina, the rod interneurons are not organized in a uniform neuronal module that is simply scaled up from central to peripheral retina. Moreover, peripheral fields in superior and inferior retina that have equivalent densities of each neuronal type show markedly different rod bipolar to AII amacrine convergence ratios, with the result that many more rod photoreceptors converge on an AII amacrine cell in superior retina. In rabbit retina, much of the convergence in the rod circuit occurs in the outer retina whereas, in central cat retina, it is more evenly distributed between the inner and outer retina.

  11. Urolithiasis and cystotomy in the rabbit.

    PubMed

    Brown, Cyndi

    2011-03-01

    Cystotomy is a surgical incision into the urinary bladder, which may be required for removal of calculi, diagnosis of tumors or refractory urinary tract infections, or repair of ectopic ureters and ruptured bladders. This column describes the indications and techniques for cystotomy in the rabbit. PMID:21326187

  12. Dystocia in a rabbit (Oryctolagus cuniculus).

    PubMed

    Dickie, Erica

    2011-01-01

    A 4-year-old female dwarf lop rabbit was presented with dystocia after mis-mating. Abdominal palpation, vaginal examination, and radiography confirmed that the doe was carrying 3 kits. Treatment for the dystocia consisted of gentle manual extraction of the fetuses and fetal membranes, and administration of oxytocin and calcium borogluconate.

  13. Dystocia in a rabbit (Oryctolagus cuniculus)

    PubMed Central

    Dickie, Erica

    2011-01-01

    A 4-year-old female dwarf lop rabbit was presented with dystocia after mis-mating. Abdominal palpation, vaginal examination, and radiography confirmed that the doe was carrying 3 kits. Treatment for the dystocia consisted of gentle manual extraction of the fetuses and fetal membranes, and administration of oxytocin and calcium borogluconate. PMID:21461214

  14. STUDIES ON RABBIT LYMPHOCYTES IN VITRO

    PubMed Central

    Sell, Stewart; Rowe, David S.; Gell, P. G. H.

    1965-01-01

    In vitro cultures of the peripheral blood lymphocytes of rabbits may be stimulated with phytohaemagglutinin, staphylococcal filtrate, antiallotype serum, or sheep anti-rabbit whole serum to synthesize protein, RNA and DNA as indicated by the incorporation of radiolabelled precursor substances into these products. A sequence of events found in all stimulated cultures characteristically shows protein synthesis followed by RNA synthesis, histologic blast transformation, DNA synthesis, and mitosis, with the complete sequence requiring 48 hours. All four stimulants induce essentially identical metabolic changes. Characterization of the proteins synthesized by lymphocytes in vitro has failed to demonstrate immunoglobulin synthesis by stimulated or non-stimulated cultures. It is concluded that the majority of proteins produced by peripheral lymphocytes stimulated in vitro are most likely cellular proteins related to the metabolic alterations necessary for mitosis. Absorption of sheep antisera to whole rabbit serum with rabbit IgG does not always remove the transforming capacity of the sheep antisera. Thus, it is likely that antibodies to proteins other than IgG present in the small lymphocyte may also be able to stimulate transformation. A possible common mechanism for the induction of lymphoblast transformation may be the ability of both specific and non-specific stimulants to react with protein constituents of the lymphocyte which may also be present in serum. PMID:4954762

  15. Use of Irradiated Foods

    NASA Technical Reports Server (NTRS)

    Brynjolfsson, A.

    1985-01-01

    The safety of irradiated foods is reviewed. Guidelines and regulations for processing irradiated foods are considered. The radiolytic products formed in food when it is irradiated and its wholesomeness is discussed. It is concluded that food irradiation processing is not a panacea for all problems in food processing but when properly used will serve the space station well.

  16. Diode laser thermotherapy in the treatment of hepatic tumors in rabbits

    NASA Astrophysics Data System (ADS)

    Prudhomme, Michel; Pierredon, Marie-Ange; Tang, Jing; Lopez, Francois-Michel; Godlewski, Guilhem; Schoenenberger, Klaus; Rinck, Klauss; Delacretaz, Guy P.

    1996-01-01

    Laser induced thermotherapy (LITT) has been recently developed for treating deep seated tumors. Diode laser (830 nm) is suitable for LITT, because of its high penetration in tissue. The present animal experiment was conducted to evaluate the performance of a diode laser for treating liver tumors in rabbits. Fifty-two New Zealand rabbits were grafted in liver with a Vx2 tumor model. They were treated at a tumor size of 8 mm diameter. A laser energy of 1 350 J (power: 1.5 W; irradiation time 900 s) was delivered through a 300 micrometer fiber implanted in the center of the tumor. Our experiment was divided in two parts: (1) A survival study: we compared the medians survival between untreated tumors (Group A, n equals 21) and irradiated tumors (Group B, n equals 21), (2) An evaluation of LITT efficiency on day 7 (Group C, n equals 5) and at day 14 (Group D, n equals 5). We compared at day 7 and day 14 the radiologic data (ultrasonography and MRI realized before and after irradiation) to the microscopic examinations (haematoxylin eosine stain and picrosirius red F3BA). The results were a median survival not significantly different in group B (laser) than in group A (control) and an efficiency only at short time (on day 7). There was a good correlation between radiologic data and microscopic examinations in groups C and D. The picrosirius red F3BA estimated the extent of thermal damage. In conclusion, these disappointing results are due to an insufficient irradiation of peritumoral tissue and to the Vx2 aggressivity (undifferentiated). Using multiple optical fiber could improve the LITT efficiency. The correlation between radiological and microscopic findings would allow us to quantify the results of LITT.

  17. Pneumatic artificial rubber muscle using shape-memory polymer sheet with embedded electrical heating wire

    NASA Astrophysics Data System (ADS)

    Takashima, Kazuto; Sugitani, Kazuhiro; Morimoto, Naohiro; Sakaguchi, Seiya; Noritsugu, Toshiro; Mukai, Toshiharu

    2014-12-01

    Shape-memory polymer (SMP) can be deformed by applying a small load above its glass transition temperature (Tg). Shape-memory polymer maintains its shape after it has cooled below Tg and returns to a predefined shape when subsequently heated above Tg. The reversible change in the elastic modulus between the glassy and rubbery states of an SMP can be on the order of several hundred times. Based on the change in stiffness of the SMP in relation to the change in temperature, the present study attempts to evaluate the application of the SMP to soft actuators of a robot. In order to control the temperature of the SMP, we developed an SMP sheet with an embedded electrical heating wire. We formed a uniform, thin SMP sheet without air bubbles using a heat press. The SMP sheet with a heating wire can be heated quickly and can be maintained at a constant temperature. Moreover, the effects of the embedded wire on the mechanical properties in bending and tensile tests were small. Then, we applied the SMP sheet with the embedded electrical heating wire to a pneumatic artificial rubber muscle. The enhanced versatility of SMP sheet applications is demonstrated through a series of experiments conducted using a prototype. The initial shape and bending displacement of the pneumatic artificial rubber muscle can be changed by controlling the temperature of the SMP sheet.

  18. A simple pneumatic device for plunge-freezing cells grown on electron microscopy grids.

    PubMed

    Cole, R; Matuszek, G; See, C; Rieder, C L

    1990-10-01

    A detailed design for a simple and inexpensive variable-speed (1.0-5.8 m s-1) pneumatic plunge-freezing device is presented. Cultured cells, grown on Formvar-coated 75-mesh gold finder grids, are pneumatically driven into a stirring mixture of propane/isopentane (3:1) cooled by liquid nitrogen (LN2). Premature freezing of the sample in the cryogenic vapors above the cryogen is prevented by plunging through an entry tube into an insulating box, to which a partial vacuum is applied. The cryogenic vapors are drafted into the box at the level of the liquid cryogen by the vacuum, thereby preventing a layer of cold gas from collecting above the cryogen. To prevent the sample from thawing during transfer from the cryogen to the substitution medium, the box top is removed and compressed air is forced through a corrugated tube running the length of the box. The resulting boiling LN2 creates an atmosphere below -120 degrees C in which the transfer can be accomplished. PMID:2213239

  19. Humphry Davy, nitrous oxide, the Pneumatic Institution, and the Royal Institution.

    PubMed

    West, John B

    2014-11-01

    Humphry Davy (1778-1829) has an interesting place in the history of respiratory gases because the Pneumatic Institution in which he did much of his early work signaled the end of an era of discovery. The previous 40 years had seen essentially all of the important respiratory gases described, and the Institution was formed to exploit their possible value in medical treatment. Davy himself is well known for producing nitrous oxide and demonstrating that its inhalation could cause euphoria and heightened imagination. His thinking influenced the poets Samuel Taylor Coleridge and William Wordsworth, and perhaps we can claim that our discipline colored the poetry of the Romantic Movement. Davy was also the first person to measure the residual volume of the lung. The Pneumatic Institution was the brainchild of Thomas Beddoes, who had trained in Edinburgh under Joseph Black, who discovered carbon dioxide. Later Davy moved to the Royal Institution in London formed, in part, to diffuse the knowledge of scientific discoveries to the general public. Davy was a brilliant lecturer and developed an enthusiastic following. In addition he exploited the newly described electric battery to discover several new elements. He also invented the safety lamp in response to a series of devastating explosions in coal mines. Ultimately Davy became president of the Royal Society, a remarkable honor for somebody with such humble origins. Another of his important contributions was to introduce Michael Faraday (1791-1867) to science. Faraday became one of the most illustrious British scientists of all time. PMID:25172910

  20. A pneumatic leg brace for the treatment of tibial stress fractures.

    PubMed

    Whitelaw, G P; Wetzler, M J; Levy, A S; Segal, D; Bissonnette, K

    1991-09-01

    Forty-two competitive athletes with posterior medial pain in the lower one-half of the tibia were evaluated by plain roentgenograms and bone scans. Twenty stress fractures were diagnosed in 17 patients by plain roentgenograms or bone scans or both. The remaining 25 patients were diagnosed as having shin splints. All 42 patients subsequently had a pneumatic leg brace applied to the affected limb or limbs. The 17 patients with stress fractures were able to ambulate without pain and were allowed to resume light training in an average of one week. Their injuries were nontender to palpation. The patients were allowed to resume intensive training at an average of 3.7 weeks postinjury. Patients returned to competition at the preinjury level in an average of 5.3 weeks after application of the brace. The pneumatic leg brace allowed the athletes with tibial stress fractures to begin pain-free ambulation and rehabilitation, thus facilitating the maintenance of their cardiovascular fitness and permitting an early return to competition.

  1. Supinator Extender (SUE): a pneumatically actuated robot for forearm/wrist rehabilitation after stroke.

    PubMed

    Allington, James; Spencer, Steven J; Klein, Julius; Buell, Meghan; Reinkensmeyer, David J; Bobrow, James

    2011-01-01

    The robot described in this paper, SUE (Supinator Extender), adds forearm/wrist rehabilitation functionality to the UCI BONES exoskeleton robot and to the ArmeoSpring rehabilitation device. SUE is a 2-DOF serial chain that can measure and assist forearm supination-pronation and wrist flexion-extension. The large power to weight ratio of pneumatic actuators allows SUE to achieve the forces needed for rehabilitation therapy while remaining lightweight enough to be carried by BONES and ArmeoSpring. Each degree of freedom has a range of 90 degrees, and a nominal torque of 2 ft-lbs. The cylinders are mounted away from the patient's body on the lateral aspect of the arm. This is to prevent the danger of a collision and maximize the workspace of the arm robot. The rotation axis used for supination-pronation is a small bearing just below the subject's wrist. The flexion-extension motion is actuated by a cantilevered pneumatic cylinder, which allows the palm of the hand to remain open. Data are presented that demonstrate the ability of SUE to measure and cancel forearm/wrist passive tone, thereby extending the active range of motion for people with stroke. PMID:22254624

  2. A pneumatic pressure-driven multi-throughput microfluidic circulation culture system.

    PubMed

    Satoh, T; Narazaki, G; Sugita, R; Kobayashi, H; Sugiura, S; Kanamori, T

    2016-06-21

    Here, we report a pneumatic pressure-driven microfluidic device capable of multi-throughput medium circulation culture. The circulation culture system has the following advantages for application in drug discovery: (i) simultaneous operation of multiple circulation units, (ii) use of a small amount of circulating medium (3.5 mL), (iii) pipette-friendly liquid handling, and (iv) a detachable interface with pneumatic pressure lines via sterile air-vent filters. The microfluidic device contains three independent circulation culture units, in which human umbilical vein endothelial cells (HUVECs) were cultured under physiological shear stress induced by circulation of the medium. Circulation of the medium in the three culture units was generated by programmed sequentially applied pressure from two pressure-control lines. HUVECs cultured in the microfluidic device were aligned under a one-way circulating flow with a shear stress of 10 dyn cm(-2); they exhibited a randomly ordered alignment under no shear stress and under reciprocating flow with a shear stress of 10 dyn cm(-2). We also observed 2.8- to 4.9-fold increases in expression of the mRNAs of endothelial nitric oxide synthase and thrombomodulin under one-way circulating flow with a shear stress of 10 dyn cm(-2) compared with conditions of no shear stress or reciprocating flow. PMID:27229626

  3. Design of a Pneumatic Tool for Manual Drilling Operations in Confined Spaces

    NASA Astrophysics Data System (ADS)

    Janicki, Benjamin

    This master's thesis describes the design process and testing results for a pneumatically actuated, manually-operated tool for confined space drilling operations. The purpose of this device is to back-drill pilot holes inside a commercial airplane wing. It is lightweight, and a "locator pin" enables the operator to align the drill over a pilot hole. A suction pad stabilizes the system, and an air motor and flexible drive shaft power the drill. Two testing procedures were performed to determine the practicality of this prototype. The first was the "offset drill test", which qualified the exit hole position error due to an initial position error relative to the original pilot hole. The results displayed a linear relationship, and it was determined that position errors of less than .060" would prevent the need for rework, with errors of up to .030" considered acceptable. For the second test, a series of holes were drilled with the pneumatic tool and analyzed for position error, diameter range, and cycle time. The position errors and hole diameter range were within the allowed tolerances. The average cycle time was 45 seconds, 73 percent of which was for drilling the hole, and 27 percent of which was for positioning the device. Recommended improvements are discussed in the conclusion, and include a more durable flexible drive shaft, a damper for drill feed control, and a more stable locator pin.

  4. Space Station and Shuttle Payloads: Rack Insertion Device Pneumatic Assembly Setup and Test

    NASA Technical Reports Server (NTRS)

    Conde, Nathan

    2007-01-01

    As part of my KSC summer internship, I was given the very cool task of writing a test preparation sheet (TPS). A TPS is a set of instructions for certain procedures or tasks, and serves as the documentation for the tasks. TPSs guide task leaders and technicians throughout the work procedures, safely, informing them of what steps will be hazardous, what precautions must be taken, and what to do in the case of an accident or emergency. I was placed in Boeing's Resupply & Return Division (R&R). R&R is responsible for sending up food and supplies to the International Space Station (ISS) with the use of three Italian Multi Purpose Logistics Modules - Leonardo, Donatello, and Raffaello. The supplies are loaded into Resupply Stowage Racks (RSRs) or Resupply Stowage Platforms (RSPs) (though, both are usually referred to as racks), depending on their size and shape. These racks are loaded into the modules with the help of a specialized crane known as the Rack Insertion Device (RID). The RID rests on four pneumatic air jacks, these allow for an operator to raise or lower the RID. The pneumatic air system supplies the air jacks with the necessary air pressure required to lift the RID.

  5. Supinator Extender (SUE): a pneumatically actuated robot for forearm/wrist rehabilitation after stroke.

    PubMed

    Allington, James; Spencer, Steven J; Klein, Julius; Buell, Meghan; Reinkensmeyer, David J; Bobrow, James

    2011-01-01

    The robot described in this paper, SUE (Supinator Extender), adds forearm/wrist rehabilitation functionality to the UCI BONES exoskeleton robot and to the ArmeoSpring rehabilitation device. SUE is a 2-DOF serial chain that can measure and assist forearm supination-pronation and wrist flexion-extension. The large power to weight ratio of pneumatic actuators allows SUE to achieve the forces needed for rehabilitation therapy while remaining lightweight enough to be carried by BONES and ArmeoSpring. Each degree of freedom has a range of 90 degrees, and a nominal torque of 2 ft-lbs. The cylinders are mounted away from the patient's body on the lateral aspect of the arm. This is to prevent the danger of a collision and maximize the workspace of the arm robot. The rotation axis used for supination-pronation is a small bearing just below the subject's wrist. The flexion-extension motion is actuated by a cantilevered pneumatic cylinder, which allows the palm of the hand to remain open. Data are presented that demonstrate the ability of SUE to measure and cancel forearm/wrist passive tone, thereby extending the active range of motion for people with stroke.

  6. Design of a pneumatically powered wearable exoskeleton with biomimetic support and actuation

    NASA Astrophysics Data System (ADS)

    Sergeyev, A.; Alaraje, N.; Seidel, C.; Carlson, Z.; Breda, B.

    Powered exoskeletons are designed to assist and protect the wearer. Depending on the situation they may be used to protect soldiers and construction workers, aid the survival of people in dangerous environments, or assist patients in rehabilitation. Regardless of the application there are strict requirements for designing and producing exoskeleton suites. They must be durable but light weight and flexible, have reliable power control and modulation, capable of detecting unsafe and invalid motions, and may require significant weight lifting capabilities. In this article we present an on-going research on robotic exoskeleton replicating of human muscle functions. A single wearable knee-joint prototype described in this article combines the use of soft pneumatic muscle-like actuators and a control system based off the users own natural muscle signals. The Pneumatic Exoskeleton uses bioelectrical signals to detect movement intention from the pilot. This paper details the technical design aspects of a lower-limb robotic exoskeleton with possibility of further expansion to fully functioning robotic exoskeleton suit.

  7. Humphry Davy, nitrous oxide, the Pneumatic Institution, and the Royal Institution.

    PubMed

    West, John B

    2014-11-01

    Humphry Davy (1778-1829) has an interesting place in the history of respiratory gases because the Pneumatic Institution in which he did much of his early work signaled the end of an era of discovery. The previous 40 years had seen essentially all of the important respiratory gases described, and the Institution was formed to exploit their possible value in medical treatment. Davy himself is well known for producing nitrous oxide and demonstrating that its inhalation could cause euphoria and heightened imagination. His thinking influenced the poets Samuel Taylor Coleridge and William Wordsworth, and perhaps we can claim that our discipline colored the poetry of the Romantic Movement. Davy was also the first person to measure the residual volume of the lung. The Pneumatic Institution was the brainchild of Thomas Beddoes, who had trained in Edinburgh under Joseph Black, who discovered carbon dioxide. Later Davy moved to the Royal Institution in London formed, in part, to diffuse the knowledge of scientific discoveries to the general public. Davy was a brilliant lecturer and developed an enthusiastic following. In addition he exploited the newly described electric battery to discover several new elements. He also invented the safety lamp in response to a series of devastating explosions in coal mines. Ultimately Davy became president of the Royal Society, a remarkable honor for somebody with such humble origins. Another of his important contributions was to introduce Michael Faraday (1791-1867) to science. Faraday became one of the most illustrious British scientists of all time.

  8. A novel BCI-controlled pneumatic glove system for home-based neurorehabilitation.

    PubMed

    Coffey, Aodhán L; Leamy, Darren J; Ward, Tomás E

    2014-01-01

    Commercially available devices for Brain-Computer Interface (BCI)-controlled robotic stroke rehabilitation are prohibitively expensive for many researchers who are interested in the topic and physicians who would utilize such a device. Additionally, they are cumbersome and require a technician to operate, increasing the inaccessibility of such devices for home-based robotic stroke rehabilitation therapy. Presented here is the design, implementation and test of an inexpensive, portable and adaptable BCI-controlled hand therapy device. The system utilizes a soft, flexible, pneumatic glove which can be used to deflect the subject's wrist and fingers. Operation is provided by a custom-designed pneumatic circuit. Air flow is controlled by an embedded system, which receives serial port instruction from a PC running real-time BCI software. System tests demonstrate that glove control can be successfully driven by a real-time BCI. A system such as the one described here may be used to explore closed loop neurofeedback rehabilitation in stroke relatively inexpensively and potentially in home environments.

  9. A novel pneumatic micropipette aspiration method using a balance pressure model.

    PubMed

    Zhao, Qili; Wu, Ming; Cui, Maosheng; Qin, Yanding; Yu, Jin; Sun, Mingzhu; Zhao, Xin; Feng, Xizeng

    2013-12-01

    This paper presents a novel micropipette aspiration (MA) method based on a common pneumatic micro-injection system. This method is the first to quantify the influence of capillary effect on aspiration pressure using a balance pressure model, and in return, uses the capillary effect to quantify the aspiration pressure. Subsequently, the seal between the cell and the micropipette is detected to judge and exclude the ineffective MA attempts. The rationality of the balance pressure model is validated by the designed micropipette-filling experiments. Through applied to elasticity-determination of the cells with different sizes, the feasibility and versatility of this MA method are proved. With abilities to quantify aspiration pressures and detect the seam between the cell and the micropipette, our method is expected to advance the application of the commercial pneumatic injector in the MA of cells. Moreover, with the quantified volume of the liquid entering into the micropipette during MA process, our method also has a potential applicability to the study of the permeability of the cell membrane in the future.

  10. A novel pneumatic micropipette aspiration method using a balance pressure model

    NASA Astrophysics Data System (ADS)

    Zhao, Qili; Wu, Ming; Cui, Maosheng; Qin, Yanding; Yu, Jin; Sun, Mingzhu; Zhao, Xin; Feng, Xizeng

    2013-12-01

    This paper presents a novel micropipette aspiration (MA) method based on a common pneumatic micro-injection system. This method is the first to quantify the influence of capillary effect on aspiration pressure using a balance pressure model, and in return, uses the capillary effect to quantify the aspiration pressure. Subsequently, the seal between the cell and the micropipette is detected to judge and exclude the ineffective MA attempts. The rationality of the balance pressure model is validated by the designed micropipette-filling experiments. Through applied to elasticity-determination of the cells with different sizes, the feasibility and versatility of this MA method are proved. With abilities to quantify aspiration pressures and detect the seam between the cell and the micropipette, our method is expected to advance the application of the commercial pneumatic injector in the MA of cells. Moreover, with the quantified volume of the liquid entering into the micropipette during MA process, our method also has a potential applicability to the study of the permeability of the cell membrane in the future.

  11. Vitreous flow rates through dual pneumatic cutters: effects of duty cycle and cut rate

    PubMed Central

    Abulon, Dina Joy K

    2015-01-01

    Purpose We aimed to investigate effects of instrument settings on porcine vitreous flow rates through dual pneumatic high-speed vitrectomy probes. Methods The CONSTELLATION® Vision System was tested with 250, 450, and 650 mmHg of vacuum using six ULTRAVIT® vitrectomy probes of each diameter (25+®, 25, 23, and 20 gauge) operated from 500 cuts per minute (cpm) up to 5,000 cpm. Duty cycle modes tested included biased open, 50/50, and biased closed. Flow rates were calculated by assessing the change in weight of porcine eyes during vitreous aspiration. Volumetric flow rate was measured with a computer-connected electronic scale. Results At lower cut rates, the biased open mode produced higher flow than did the 50/50 mode, which produced higher flow than did the biased closed mode. In the biased closed and 50/50 modes, vitreous flow rates tended to increase with increasing cut rate. Vitreous flow rates in the biased open duty cycle mode remained relatively constant across cut rates. Conclusion Vitreous flow rates through dual pneumatic vitrectomy probes could be manipulated by changing the duty cycle modes on the vitrectomy system. Differences in duty cycle behavior suggest that high-speed cut rates of 5,000 cpm may optimize vitreous aspiration. PMID:25709386

  12. Fabrication, assembly, bench and drilling tests of two prototype downhole pneumatic turbine motors: Final technical report

    SciTech Connect

    Bookwalter, R.; Duettra, P.D.; Johnson, P.; Lyons, W.C.; Miska, S.

    1987-04-01

    The first and second prototype downhole pneumatic turbine motors have been fabricated, assembled and tested. All bench tests showed that the motor will produce horsepower and bit speeds approximating the predicted values. Specifically, the downhole pneumatic turbine motor produced approximately 50 horsepower at 100 rpm, while being supplied with about 3600 SCFM of compressed air. The first prototype was used in a drilling test from a depth of 389 feet to a depth of 789 feet in the Kirtland formation. This first prototype motor drilled at a rate exceeding 180 ft/hr, utilizing only 3000 SCFM of compressed air. High temperature tests (at approximately 460/sup 0/F) were carried out on the thrust assembly and the gearboxes for the two prototypes. These components operated successfully at these temperatures. Although the bench and drilling tests were successful, the tests revealed design changes that should be made before drilling tests are carried out in geothermal boreholes at the Geysers area, near Santa Rosa, California.

  13. Mechanical performance of artificial pneumatic muscles to power an ankle-foot orthosis.

    PubMed

    Gordon, Keith E; Sawicki, Gregory S; Ferris, Daniel P

    2006-01-01

    We developed a powered ankle-foot orthosis that uses artificial pneumatic muscles to produce active plantar flexor torque. The purpose of this study was to quantify the mechanical performance of the orthosis during human walking. Three subjects walked at a range of speeds wearing ankle-foot orthoses with either one or two artificial muscles working in parallel. The orthosis produced similar total peak plantar flexor torque and network across speeds independent of the number of muscles used. The orthosis generated approximately 57% of the peak ankle plantar flexor torque during stance and performed approximately 70% of the positive plantar flexor work done during normal walking. Artificial muscle bandwidth and force-length properties were the two primary factors limiting torque production. The lack of peak force and work differences between single and double muscle conditions can be explained by force-length properties. Subjects altered their ankle kinematics between conditions resulting in changes in artificial muscle length. In the double muscle condition greater plantar flexion yielded shorter artificial muscles lengths and decreased muscle forces. This finding emphasizes the importance of human testing in the design and development of robotic exoskeleton devices for assisting human movement. The results of this study outline the mechanical performance limitations of an ankle-foot orthosis powered by artificial pneumatic muscles. This orthosis could be valuable for gait rehabilitation and for studies investigating neuromechanical control of human walking. PMID:16023126

  14. Assistive acting movement therapy devices with pneumatic rotary-type soft actuators.

    PubMed

    Wilkening, André; Baiden, David; Ivlev, Oleg

    2012-12-01

    Inherent compliance and assistive behavior are assumed to be essential properties for safe human-robot interaction. Rehabilitation robots demand the highest standards in this respect because the machine interacts directly with weak persons who are often sensitive to pain. Using novel soft fluidic actuators with rotary elastic chambers (REC actuators), compact, lightweight, and cost-effective therapeutic devices can be developed. This article describes modular design and control strategies for new assistive acting robotic devices for upper and lower extremities. Due to the inherent compliance and natural back-drivability of pneumatic REC actuators, these movement therapy devices provide gentle treatment, whereby the interaction forces between humans and the therapy device are estimated without the use of expensive force/torque sensors. An active model-based gravity compensation based on separated models of the robot and of the individual patient's extremity provides the basis for effective assistive control. The utilization of pneumatic actuators demands a special safety concept, which is merged with control algorithms to provide a sufficient level of safeness and to catch any possible system errors and/or emergency situations. A self-explanatory user interface allows for easy, intuitive handling. Prototypes are very comfortable for use due to several control routines that work in the background. Assistive devices have been tested extensively with several healthy persons; the knee/hip movement therapy device is now under clinical trials at the Clinic for Orthopaedics and Trauma Surgery at the Klinikum Stuttgart.

  15. Centrifugo-pneumatic sedimentation, re-suspension and transport of microparticles.

    PubMed

    Zhao, Y; Schwemmer, F; Zehnle, S; von Stetten, F; Zengerle, R; Paust, N

    2015-11-01

    Microparticles are widely used as solid phase for affinity-based separation. Here, we introduce a new method for automated handling of microparticles in centrifugal microfluidics that is not restricted by the particle size and requires neither auxiliary means such as magnets nor coating of microfluidic structures. All steps are initiated and controlled by the speed of rotation only. It is based on storage and "on demand" release of pneumatic energy within tunable time frames: a slow release of the pneumatic energy triggers a first fluidic path through which the supernatant above the sedimented particles is removed. An abrupt release triggers a second path which allows for liquid routing and transport of the re-suspended particles. Re-suspension of particles is thereby achieved by quickly changing the speed of rotation. We demonstrate the exchange of the particle carrier medium with a supernatant removal efficiency of more than 99.5% and a particle loss below 4%. Re-suspension and subsequent transport of suspended particles show a particle loss below 7%. The method targets the automation of particle-based assays e.g. DNA extractions and immunoassays. It is compatible with monolithic integration and suitable for mass production technologies e.g. thermoforming or injection moulding. PMID:26348615

  16. Assistive acting movement therapy devices with pneumatic rotary-type soft actuators.

    PubMed

    Wilkening, André; Baiden, David; Ivlev, Oleg

    2012-12-01

    Inherent compliance and assistive behavior are assumed to be essential properties for safe human-robot interaction. Rehabilitation robots demand the highest standards in this respect because the machine interacts directly with weak persons who are often sensitive to pain. Using novel soft fluidic actuators with rotary elastic chambers (REC actuators), compact, lightweight, and cost-effective therapeutic devices can be developed. This article describes modular design and control strategies for new assistive acting robotic devices for upper and lower extremities. Due to the inherent compliance and natural back-drivability of pneumatic REC actuators, these movement therapy devices provide gentle treatment, whereby the interaction forces between humans and the therapy device are estimated without the use of expensive force/torque sensors. An active model-based gravity compensation based on separated models of the robot and of the individual patient's extremity provides the basis for effective assistive control. The utilization of pneumatic actuators demands a special safety concept, which is merged with control algorithms to provide a sufficient level of safeness and to catch any possible system errors and/or emergency situations. A self-explanatory user interface allows for easy, intuitive handling. Prototypes are very comfortable for use due to several control routines that work in the background. Assistive devices have been tested extensively with several healthy persons; the knee/hip movement therapy device is now under clinical trials at the Clinic for Orthopaedics and Trauma Surgery at the Klinikum Stuttgart. PMID:23241570

  17. Methane emissions from process equipment at natural gas production sites in the United States: pneumatic controllers.

    PubMed

    Allen, David T; Pacsi, Adam P; Sullivan, David W; Zavala-Araiza, Daniel; Harrison, Matthew; Keen, Kindal; Fraser, Matthew P; Daniel Hill, A; Sawyer, Robert F; Seinfeld, John H

    2015-01-01

    Emissions from 377 gas actuated (pneumatic) controllers were measured at natural gas production sites and a small number of oil production sites, throughout the United States. A small subset of the devices (19%), with whole gas emission rates in excess of 6 standard cubic feet per hour (scf/h), accounted for 95% of emissions. More than half of the controllers recorded emissions of 0.001 scf/h or less during 15 min of measurement. Pneumatic controllers in level control applications on separators and in compressor applications had higher emission rates than controllers in other types of applications. Regional differences in emissions were observed, with the lowest emissions measured in the Rocky Mountains and the highest emissions in the Gulf Coast. Average methane emissions per controller reported in this work are 17% higher than the average emissions per controller in the 2012 EPA greenhouse gas national emission inventory (2012 GHG NEI, released in 2014); the average of 2.7 controllers per well observed in this work is higher than the 1.0 controllers per well reported in the 2012 GHG NEI.

  18. Water gate array for current flow or tidal movement pneumatic harnessing system

    DOEpatents

    Gorlov, Alexander M.

    1991-01-01

    The invention, which provides a system for harnessing power from current flow or tidal movement in a body of water, comprises first and second hydro-pneumatic chambers each having ingress and egress below the water surface near the river or ocean floor and water gates operative to open or seal the ports to the passage of water. In an exemplary embodiment, the gates are sychronized by shafts so that the ingress ports of each chamber are connected to the egress ports of each other chamber. Thus, one set of gates is closed, while the other is open, thereby allowing water to flow into one chamber and build air pressure therein and allowing water to flow out of the other chamber and create a partial vacuum therein. A pipe connects the chambers, and an air turbine harnesses the air movement within the pipe. When water levels are equilibrated, the open set of gates is closed by a counterweight, and the other set is allowed to open by natural force of the water differential. The water gates may be comprised of a plurality of louvers which are ganged for simultaneous opening and closing. The system is designed to operate with air turbines or other pneumatic devices. Its design minimizes construction cost and environmental impact, yet provides a clean renewable energy source.

  19. A study of pneumatic conveying of gas-solid flow for industrial application

    NASA Astrophysics Data System (ADS)

    Al-Khateeb, Khalid A. S.; Tasnim, Rumana; Khan, Sheroz; Mohammod, Musse; Arshad, Atika; Shobaki, Mohammed M.; Haider, Samnan; Saquib, Nazmus; Rahman, Tawfilur

    2013-12-01

    The complicated nature of gas-solids' physical properties have challenged the researchers over past decades who have led their efforts in developing its' flow sensing and measurement methods. The term 'gas-solid flow' signifies dilute- or dense-phase flow with a very little concentration of solids. For conducting such flow measurement, generally velocity profile and volumetric concentration of the flow particles being conveyed are needed to be measured. An important application of gas-solid flow has taken root in the form of biomass flow in pneumatic conveying systems, and its' online measurement has proven to be an exigent research pursuit. Additionally the other applications have been explored in power plants, food, chemical and automobiles industries as well. This paper aims at exploring the evolution of flow measurement methods along with a brief explanation on existing fundamental sensing techniques. Furthermore, the most recent patents developed for such measurements in pneumatic conveying pipelines are scrutinized along with their concomitant pros and cons.

  20. Centrifugo-pneumatic sedimentation, re-suspension and transport of microparticles.

    PubMed

    Zhao, Y; Schwemmer, F; Zehnle, S; von Stetten, F; Zengerle, R; Paust, N

    2015-11-01

    Microparticles are widely used as solid phase for affinity-based separation. Here, we introduce a new method for automated handling of microparticles in centrifugal microfluidics that is not restricted by the particle size and requires neither auxiliary means such as magnets nor coating of microfluidic structures. All steps are initiated and controlled by the speed of rotation only. It is based on storage and "on demand" release of pneumatic energy within tunable time frames: a slow release of the pneumatic energy triggers a first fluidic path through which the supernatant above the sedimented particles is removed. An abrupt release triggers a second path which allows for liquid routing and transport of the re-suspended particles. Re-suspension of particles is thereby achieved by quickly changing the speed of rotation. We demonstrate the exchange of the particle carrier medium with a supernatant removal efficiency of more than 99.5% and a particle loss below 4%. Re-suspension and subsequent transport of suspended particles show a particle loss below 7%. The method targets the automation of particle-based assays e.g. DNA extractions and immunoassays. It is compatible with monolithic integration and suitable for mass production technologies e.g. thermoforming or injection moulding.