Science.gov

Sample records for pneumatic irradiation rabbit

  1. Pneumatics.

    ERIC Educational Resources Information Center

    Engelbrecht, Nancy; And Others

    This unit on pneumatics, for use in postsecondary programs, is organized in eight sections. Each section consists of information sheets with line drawings and multiple-choice questions for each topic in the sections. Answers are provided at the back of the book. The following topics are covered: (1) introduction--pressure, principles of gases,…

  2. Skeletal muscle injury induced by a pneumatic tourniquet: an enzyme- and immunohistochemical study in rabbits.

    PubMed

    Pedowitz, R A; Fridén, J; Thornell, L E

    1992-03-01

    The pathophysiology of skeletal muscle injury induced by compression beneath pneumatic tourniquets is poorly understood. Tourniquet hemostasis was induced in rabbit hindlimbs for 2 hr with a cuff inflation pressure of either 125 mm Hg (n = 5) or 350 mm Hg (n = 5). Skeletal muscle biopsies, taken 2 days later from tissue beneath and distal to the tourniquet, were frozen and analyzed using enzyme- and immunohistochemical techniques. In the 350 mm Hg tourniquet group, four of 10 thigh muscle samples demonstrated significant regional necrosis (mean 37.3% of the total cross-sectional area). Regional necrosis was not observed in thigh muscles of the 125 mm Hg tourniquet group or in any of the ischemic leg muscles. A topographic pattern of necrosis consistent with the arterial distribution of skeletal muscle suggested pathogenic events during the reperfusion period, such as granulocyte-mediated superoxide radical formation. Extremely large and rounded fibers (histochemically identified as Type IIB fibers) were observed in compressed thigh muscles, indicating differential fiber sensitivity to tourniquet compression and ischemia. The present study demonstrated significant skeletal muscle necrosis after a 2 hr tourniquet applied at a clinically relevant cuff inflation pressure. Recent studies of systemic changes associated with limb "ischemia" should be reassessed in consideration of the confounding effects of tissue compression induced beneath pneumatic tourniquets.

  3. Nerve function and structure beneath and distal to a pneumatic tourniquet applied to rabbit hindlimbs.

    PubMed

    Pedowitz, R A; Nordborg, C; Rosenqvist, A L; Rydevik, B L

    1991-01-01

    Neurophysiologic and neuropathologic changes were studied in rabbit hindlimbs after 2 hours of pneumatic tourniquet application with either 350 mmHg (n = 18) or 1,000 mmHg (n = 6) cuff inflation pressure. The toe spread reflex was decreased in 66% and absent in 33% of limbs 2 days after 350 mmHg compression, and was absent in all limbs after 1,000 mmHg compression. Compound motor action potential amplitudes (CMAPs), recorded from the abductor hallucis muscle, were significantly decreased with sciatic nerve stimulation 1 hour after 350 mmHg compression. CMAPs returned to baseline values one and two days later, however nerve conduction velocity (NCV) was still significantly decreased in the compressed sciatic nerves of these groups. In contrast, complete nerve conduction block, localized beneath the cuff's distal border, was observed two days after 1,000 mmHg compression, and NCV was still significantly decreased distal to the tourniquet zone. Using light and electron microscopy, scattered axonal degeneration, mild myelin damage, and normal nodes of Ranvier were observed two days after 350 mmHg tourniquet compression. Severe fiber damage and nodal obliteration were noted after 1,000 mmHg tourniquet compression. Although nodal invagination is probably not a significant pathogenic mechanism at clinically relevant tourniquet pressures and durations, functional abnormalities were induced by 2 hour, 350 mmHg tourniquet compression. Such changes probably correlate with clinical electromyographic abnormalities and delayed post-operative recovery following 'routine' extremity surgery using pneumatic tourniquets.

  4. Superoxide dismutase activity in radioresistant tissues of irradiated rabbits.

    PubMed

    Stoklasová, A; Kovárová, H; Ledvina, M

    1992-01-01

    The activities of Cu, Zn-containing superoxide dismutase were studied in radioresistant tissues (liver, brain, erythrocytes) of whole-body irradiated rabbits with 6.0 Gy and 24.0 Gy with local shielding. No significant changes were observed after irradiation with 6.0 Gy. Both the changes in Cu, Zn-SOD activity and the protein concentrations were more pronounced after exposure to 24.0 Gy with local shielding of the head and abdominal region. The dose on the shielded regions was about 6.0 Gy. Local shielding of rabbits irradiated with a lethal dose 24.0 Gy influenced positively the survival of animals. However, the decrease in SOD activity on 60th day after irradiation seems to be unfavourable for further survival of rabbits, if we accept that SOD content in tissue is maintained at a rather constant level.

  5. Late degeneration in rabbit tissues after irradiation by heavy ions

    NASA Technical Reports Server (NTRS)

    Lett, J. T.; Cox, A. B.; Keng, P. C.; Lee, A. C.; Su, C. M.; Bergtold, D. S.

    1980-01-01

    Results are presented for investigations of the late effects of heavy-ion irradiation on rabbit tissues which were undertaken to assess the hazards associated with the long-term exposure of humans to heavy ions in space during such activities as the construction of solar power stations or voyages to Mars. White rabbits approximately six weeks old were exposed to various doses of collimated beams of 400-MeV/n Ne ions, 570 MeV/n Ar ions and Co-60 gamma rays directed through both eyes, and the responses of the various tissues (hair follicles, skin, cornea, lens, retina, Harderian glands, bone and forebrain) were examined. Proliferating tissues are found to exhibit high damage levels in the early and late periods following irradiation, while terminally differentiating tissues repond to radiation most intensely in the late period, years after irradiation, with no intermediate recovery. The results obtained from rabbits are used to predict the occurrence of late tissue degeneration in the central nervous system, terminally differentiating systems and stem cells of humans one or more decades following exposure to radiation levels anticipated during long-duration space flights. The studies also indicate that tissues may be prematurely aged in the sense that tissue life spans may be shortened without the development of malignancies.

  6. Late degeneration in rabbit tissues after irradiation by heavy ions

    NASA Technical Reports Server (NTRS)

    Lett, J. T.; Cox, A. B.; Keng, P. C.; Lee, A. C.; Su, C. M.; Bergtold, D. S.

    1980-01-01

    Results are presented for investigations of the late effects of heavy-ion irradiation on rabbit tissues which were undertaken to assess the hazards associated with the long-term exposure of humans to heavy ions in space during such activities as the construction of solar power stations or voyages to Mars. White rabbits approximately six weeks old were exposed to various doses of collimated beams of 400-MeV/n Ne ions, 570 MeV/n Ar ions and Co-60 gamma rays directed through both eyes, and the responses of the various tissues (hair follicles, skin, cornea, lens, retina, Harderian glands, bone and forebrain) were examined. Proliferating tissues are found to exhibit high damage levels in the early and late periods following irradiation, while terminally differentiating tissues repond to radiation most intensely in the late period, years after irradiation, with no intermediate recovery. The results obtained from rabbits are used to predict the occurrence of late tissue degeneration in the central nervous system, terminally differentiating systems and stem cells of humans one or more decades following exposure to radiation levels anticipated during long-duration space flights. The studies also indicate that tissues may be prematurely aged in the sense that tissue life spans may be shortened without the development of malignancies.

  7. Late degeneration in rabbit tissues after irradiation by heavy ions.

    PubMed

    Lett, J T; Cox, A B; Keng, P C; Lee, A C; Su, C M; Bergtold, D S

    1980-01-01

    In 1974, using the rabbit as a model, we began long-term experiments designed to help in the evaluation of the hazards to man from extended exposure to heavy ions in space. Such exposure would occur, for example, during the construction of solar power stations in stationary orbits or on round trips to Mars. Our experiments with 400 MeV/nucleon Ne ions and 570 MeV/nucleon Ar ions have shown that true late effects of a degenerative nature are manifested only years after irradiation. At the appropriate doses (the high end of the experimental dose range), the magnitudes of the late effects are comparable with those encountered in human patients given radiation therapy with neutrons. Such comparisons show that the rabbit experiments are applicable to man. Given that basis, the results from the low end of the experimental dose range lead to the conclusion that astronauts subjected to the radiation fluxes anticipated during flights of the above duration could experience late radiation effects one or more decades after exposure. Late degenerative changes will occur in tissues of the central nervous system, terminally differentiating systems and stem cell populations. The studies also indicate that individual tissues may be "prematurely aged" by radiation in the sense that the "life spans" of those tissues can be decreased without the appearance of malignancies.

  8. Effects of pre- and postoperative irradiation on the healing of bone grafts in the rabbit

    SciTech Connect

    Morales, M.J.; Marx, R.E.; Gottlieb, C.F.

    1987-01-01

    Healing of cellular bone grafts irradiated at various times in the postsurgical course was compared to the healing characteristics of bone grafts placed into already irradiated tissue and to controls of irradiated host mandible in a rabbit model. Physical graft consolidation was assessed by load stress characteristics and serial histologic examination. Results indicated that grafts placed into already irradiated tissues failed to form bone in both phases of expected regeneration resulting in structurally weakened and histologically deficient ossicles. Bone grafts irradiated after placement were tolerant of irradiation. Bone grafts irradiated after four weeks were found to be less affected by irradiation than those irradiated within the first four weeks, forming an ossicle structurally and histologically superior to that of bone ossicles developed from grafts placed into irradiated tissues.

  9. Disposable rabbit

    DOEpatents

    Lewis, Leroy C.; Trammell, David R.

    1986-01-01

    A disposable rabbit for transferring radioactive samples in a pneumatic transfer system comprises aerated plastic shaped in such a manner as to hold a radioactive sample and aerated such that dissolution of the rabbit in a solvent followed by evaporation of the solid yields solid waste material having a volume significantly smaller than the original volume of the rabbit.

  10. Disposal rabbit

    DOEpatents

    Lewis, L.C.; Trammell, D.R.

    1983-10-12

    A disposable rabbit for transferring radioactive samples in a pneumatic transfer system comprises aerated plastic shaped in such a manner as to hold a radioactive sample and aerated such that dissolution of the rabbit in a solvent followed by evaporation of the solid yields solid waste material having a volume significantly smaller than the original volume of the rabbit.

  11. Apraclonidine effects on ocular responses to YAG laser irradiation to the rabbit iris

    SciTech Connect

    Sugiyama, K.; Kitazawa, Y.; Kawai, K. )

    1990-04-01

    Apraclonidine (p-aminoclonidine) ophthalmic solution effectively reduces the rise in intraocular pressure (IOP) following anterior segment laser surgery. We tested the effect of topical 0.5% apraclonidine on intraocular pressure and on protein and prostaglandin (PG) E2 concentrations in aqueous humor following Q-switched Nd:YAG laser irradiation to the iris of albino rabbits, at an energy level of 2 to 200 mJ. IOP was measured prior to and for 24 hr after irradiation. Aqueous humor was withdrawn before and 1 hr after laser irradiation for determining protein (Lowry method) and PGE2 (radioimmunoassay). Four to seven rabbits were used for each experiment. The increase in IOP and protein concentration following laser irradiation was demonstrated to be dependent on the amount of laser energy. Apraclonidine completely abolished the IOP rise, and significantly reduced the elevation of protein content. Apraclonidine failed to affect the increase in PGE2.

  12. A new rabbit model of impaired wound healing in an X-ray-irradiated field

    PubMed Central

    Fujita, Kazutoshi; Fujiwara, Toshihiro; Sotsuka, Yohei; Tonooka, Maki; Kawai, Kenichiro; Kakibuchi, Masao

    2017-01-01

    Radiation is an important therapy for cancer with many benefits; however, its side effects, such as impaired wound healing, are a major problem. While many attempts have been made to overcome this particular disadvantage, there are few effective treatments for impaired wound healing in an X-ray-irradiated field. One reason for this deficiency is the lack of experimental models, especially animal models. We have previously reported a mouse model of impaired wound healing in which the irradiation area was restricted to the hindlimbs. In this mouse model, due to the size of the animal, a diameter of five millimeters was considered the largest wound size suitable for the model. In addition, the transplanted cells had to be harvested from other inbred animals. To investigate larger wounds and the impact of autologous specimen delivery, a rabbit model was developed. Rabbits were kept in a special apparatus to shield the body and hindlimbs while the irradiation field was exposed to radiation. Six weeks after irradiation, a 2 x 2 cm, full-thickness skin defect was made inside the irradiation field. Then, the wound area was observed over time. The wound area after irradiation was larger than that without irradiation at all time points. Both angiogenesis and collagen formation were reduced. For further study, as an example of using this model, the effect of autologous platelet-rich plasma (PRP) was observed. Autologous PRP from peripheral blood (pb-PRP) and bone marrow aspirate (bm-PRP) was processed and injected into the wounds in the irradiated field. Two weeks later, the wounds treated with bm-PRP were significantly smaller than those treated with phosphate buffer vehicle controls. In contrast, the wounds treated with pb-PRP were not significantly different from the controls. This rabbit model is useful for investigating the mechanism of impaired wound healing in an X-ray-irradiated field. PMID:28886194

  13. Gamma-Irradiated Sterile Cornea for Use in Corneal Transplants in a Rabbit Model

    PubMed Central

    Yoshida, Junko; Heflin, Thomas; Zambrano, Andrea; Pan, Qing; Meng, Huan; Wang, Jiangxia; Stark, Walter J.; Daoud, Yassine J.

    2015-01-01

    Purpose: Gamma irradiated corneas in which the donor keratocytes and endothelial cells are eliminated are effective as corneal lamellar and glaucoma patch grafts. In addition, gamma irradiation causes collagen cross inking, which stiffens collagen fibrils. This study evaluated gamma irradiated corneas for use in corneal transplantations in a rabbit model comparing graft clarity, corneal neovascularization, and edema. Methods: Penetrating keratoplasty was performed on rabbits using four types of corneal grafts: Fresh cornea with endothelium, gamma irradiated cornea, cryopreserved cornea, and fresh cornea without endothelium. Slit lamp examination was performed at postoperative week (POW) one, two, and four. Corneal clarity, edema, and vascularization were graded. Confocal microscopy and histopathological evaluation were performed. A P < 0.05 was statistically significant. Results: For all postoperative examinations, the corneal clarity and edema were statistically significantly better in eyes that received fresh cornea with endothelium compared to the other three groups (P < 0.05). At POW 1, gamma irradiated cornea scored better than the cryopreserved and fresh cornea without endothelium groups in clarity (0.9 vs. 1.5 and 2.6, respectively), and edema (0.6 vs. 0.8 and 2.0, respectively). The gamma irradiated corneas, cryopreserved corneas and the fresh corneas without endothelium, developed haze and edema after POW 2. Gamma irradiated cornea remained statistically significantly clearer than cryopreserved and fresh cornea without endothelium during the observation period (P < 0.05). Histopathology indicated an absence of keratocytes in gamma irradiated cornea. Conclusion: Gamma irradiated corneas remained clearer and thinner than the cryopreserved cornea and fresh cornea without endothelium. However, this outcome is transient. Gamma irradiated corneas are useful for lamellar and patch grafts, but cannot be used for penetrating keratoplasty. PMID:26180475

  14. Gamma-Irradiated Sterile Cornea for Use in Corneal Transplants in a Rabbit Model.

    PubMed

    Yoshida, Junko; Heflin, Thomas; Zambrano, Andrea; Pan, Qing; Meng, Huan; Wang, Jiangxia; Stark, Walter J; Daoud, Yassine J

    2015-01-01

    Gamma irradiated corneas in which the donor keratocytes and endothelial cells are eliminated are effective as corneal lamellar and glaucoma patch grafts. In addition, gamma irradiation causes collagen cross inking, which stiffens collagen fibrils. This study evaluated gamma irradiated corneas for use in corneal transplantations in a rabbit model comparing graft clarity, corneal neovascularization, and edema. Penetrating keratoplasty was performed on rabbits using four types of corneal grafts: Fresh cornea with endothelium, gamma irradiated cornea, cryopreserved cornea, and fresh cornea without endothelium. Slit lamp examination was performed at postoperative week (POW) one, two, and four. Corneal clarity, edema, and vascularization were graded. Confocal microscopy and histopathological evaluation were performed. A P < 0.05 was statistically significant. For all postoperative examinations, the corneal clarity and edema were statistically significantly better in eyes that received fresh cornea with endothelium compared to the other three groups (P < 0.05). At POW 1, gamma irradiated cornea scored better than the cryopreserved and fresh cornea without endothelium groups in clarity (0.9 vs. 1.5 and 2.6, respectively), and edema (0.6 vs. 0.8 and 2.0, respectively). The gamma irradiated corneas, cryopreserved corneas and the fresh corneas without endothelium, developed haze and edema after POW 2. Gamma irradiated cornea remained statistically significantly clearer than cryopreserved and fresh cornea without endothelium during the observation period (P < 0.05). Histopathology indicated an absence of keratocytes in gamma irradiated cornea. Gamma irradiated corneas remained clearer and thinner than the cryopreserved cornea and fresh cornea without endothelium. However, this outcome is transient. Gamma irradiated corneas are useful for lamellar and patch grafts, but cannot be used for penetrating keratoplasty.

  15. [Rabbit facial nerve damager after Nd: YAG laser irradiation: an experimental study

    PubMed

    Yu, Y C; Zhang, Z Y; Zhou, G Y; Zhu, H G

    1999-12-01

    OBJECTIVE:To investigate the change effects of rabbit facial nerve after Nd:YAG laser irradiation.METHODS: According to therapeutic laser energy density,the facial nerves of 28 rabbits were irradiated by Nd:YAG laser with 5 different laser dosages.RESULTS: The facial nerves were functionally intact with mild degeneration histologically at three weeks postoperatively,when the energy density of Nd: YAG laserlaser lower than 70J/cm(2).In the group with energy density of 140J/cm(2),facial nerve density functionally impaired with moderate degeneration which rehabilitated within six weeks. While the laser power increaseed to more than 240J/cm(2),irreversible nerve damages happened.CONCLUSION: laser thermal effect is the main cause of nerve damage,there is a positive correlation between laser dosage and nerve impairment.

  16. Activity of superoxide dismutase isoenzymes in the bone marrow of irradiated rabbits.

    PubMed

    Kovárová, H; Stoklasová, A; Ledvina, M

    1992-01-01

    The activities of total, Cu,Zn- and Mn-containing superoxide dismutase were studied in the bone marrow of whole-body irradiated rabbits with 6.0 Gy or 24.0 Gy with local shielding. Irradiation with 6.0 Gy depressed the activities of total and Cu,Zn-SOD on the 8th and 15th days, whereas the activity of Mn-SOD did not change. The exposure to 24.0 Gy with local shielding of head and abdominal region decreased Cu,Zn-SOD activity on the 4th and 60th days after irradiation, Mn-SOD activity was lower nearly at all time intervals investigated. The exposure to 24.0 Gy with shielding of whole body without head region increased markedly Cu,Zn-SOD activity, whereas Mn-SOD activity was diminished on the 8th and 15th days after irradiation in comparison with control group. Mn-SOD activity (U per 10(6) of bone marrow cells) was increased at early time intervals, the changes were not so striking after irradiation of rabbits with 24.0 Gy with shielding of whole body without head region.

  17. External beam irradiation in angioplasted arteries of hypercholesterolemic rabbits The dose and time effect

    SciTech Connect

    Kalef-Ezra, J.; Michalis, L.K.; Malamou-Mitsi, V.; Tsekeris, P.; Katsouras, C.; Boziari, A.; Toumpoulis, I.; Bozios, G.; Charchanti, A.; Sideris, D.A

    2002-03-01

    Purpose: To study the dose and time effect of external beam irradiation on the morphometry of both angioplasted and nonangioplasted arteries in a hypercholesterolemic rabbit model. Methods and materials: Eight groups of rabbit femoral arteries were studied: arteries (a) with no intervention, (b) irradiated with a 12-Gy 6 MV X-ray dose, (c) with a 18-Gy, (d) treated with balloon angioplasty, (e) dosed with 12-Gy half an hour post-angioplasty, (f) dosed with 18-Gy half an hour post-angioplasty, (g) dosed with 12-Gy 48 h post angioplasty, (g) dosed with 18-Gy 48 h post angioplasty. Results: External irradiation at either 12 or 18 Gy was not found to change vessel morphometry in noninjured arteries. The 12-Gy dose given soon after angioplasty further increased percentage stenosis (63% on the average), despite the preservation of the lumen cross-sectional area. Positive remodeling was not observed in arteries given 18-Gy half an hour post angioplasty to counterbalance the increased neointimal formation. Therefore, this treatment resulted in a drastic reduction in lumen area and in enhancement of percentage stenosis (84% on the average). On the contrary, the delayed irradiation of the angioplasted arteries at either 12 or 18 Gy was not found to influence any of the studied morphometric parameters 5 weeks after angioplasty. Conclusions: Uniform external beam irradiation up to 18 Gy was well tolerated by intact femoral arteries. Prompt 12- or 18-Gy irradiations accentuated percentage stenosis. However the lumen cross-sectional area was preserved only at the lower dose point. Delayed irradiation at any dose did not influence the restenosis process.

  18. Kinetics of (/sup 14/C-5) 8-methoxypsoralen uptake by UVA irradiated and non-irradiated rabbit eye tissues

    SciTech Connect

    Malinin, G.I.; Glew, W.B.; Roberts, W.P.; Nigra, T.P.

    1981-05-01

    Total 8-methoxypsoralen (8-MOP) in intact and UVA irradiated rabbit eye tissues and its unaltered fraction in aqueous and eye lenses were determined over the 24 hours after i.v. injection of (/sup 14/C-5) and carrier 8-MOP at the concentration of 50 microCi and 5 mg/kg. No 8-MOP was detected at the end of 24 hours in intact and irradiated aqueous, vitreous and retina in contrast to one hour when the respective levels were congruent to 220, greater than 0 and congruent to 160 ng/g. Eye-plasma drug concentration ratios were less than 0.5 initially, but increased thereafter. While the average lens 8-MOP levels of congruent to 140 ng/g remained unchanged for 24 hours, no unaltered drug was detected beyond eight hours. Measurable amounts of label at the end of 24 hours also persisted in the cornea, iris, sclera and conjunctiva.

  19. [Thermocompensatory reactions of rabbits in response to microwave irradiation at different environmental temperatures].

    PubMed

    Kolganova, O I; Zhavronkov, L P; Petin, V G; Drozd, A I; Glushakova, V S; Panferova, T A

    2001-01-01

    Thermogenic effectiveness of electromagnetic irradiation (EMI) of UHF range (7 GHz) in the dependence on intensity (10-100 mW/cm2) and environmental temperature was studied in experiments with rabbits. Synergistic interaction of EMI and high ambient temperature was established. The existence of optimal EMI and high ambient temperature was established. The existence of optimal EMI intensity at which the synergy was maximal was shown. It is concluded that this interaction should be taken into account for hygienic standardization of nonionizing EMI.

  20. Effect of low-power helium-neon laser irradiation on 13-week immobilized articular cartilage of rabbits.

    PubMed

    Bayat, Mohammad; Ansari, Anayatallah; Hekmat, Hossien

    2004-09-01

    Influence of low-power (632.8 nm, Helium-Neon, 13 J/cm2, three times a week) laser on 13-week immobilized articular cartilage was examined with rabbits knee model. Number of chondrocytes and depth of articular cartilage of experimental group were significantly higher than those of sham irradiated group. Surface morphology of sham-irradiated group had rough prominences, fibrillation and lacunae but surface morphology of experimental group had more similarities to control group than to sham irradiated group. There were marked differences between ultrastructure features of control group and experimental group in comparison with sham irradiated group. Low-power Helium-Neon laser irradiation on 13-week immobilized knee joints of rabbits neutrilized adverse effects of immobilization on articular cartilage.

  1. Bioeffect of lipohemia rabbits irradiated in oral mucosa with 650-nm diode-laser-accompanied oxygen inspiration and clinical application

    NASA Astrophysics Data System (ADS)

    Yang, Fu-Shou; Tang, Jin-Xian; Liu, Cheng; Yang, Xi-Cheng; Pang, Hi-Xiu

    1998-11-01

    The study on irradiating in oral mucosa of rabbits with 650 nm diode laser and clinical application has been reported in this paper. The result of animal experiment showed: the obvious decrease of cholesterin and triglyceride has been found among those highly lipohemia rabbits in the experiments of 650nm diode laser irradiating accompanying with oxygen, as well as the parameters of hemorheology obviously being improved, as compared with highly lipohemia rabbits un-irradiating, the statistical analysis showing P < 0.01. In the meantime, the observation of histopathology shows, the lipide decreasing in aorta wall, intramyocardinal membranous layer,and renal interstitial in the group of rabbits which are irradiated with laser and accompanying with oxygen inspiration, and even the perfectly recovered tissue in some rabbits has been seen. This experimental result is significantly for clinical application. The results of clinic application showed, that the patients employed this method which treatment cerebral infarction, lipohemia, the total effective ratio achieved 91.7 percent, perfect effect 30.6 percent.

  2. Effect of helium-neon and infrared laser irradiation on wound healing in rabbits

    SciTech Connect

    Braverman, B.; McCarthy, R.J.; Ivankovich, A.D.; Forde, D.E.; Overfield, M.; Bapna, M.S.

    1989-01-01

    We examined the biostimulating effects of helium-neon laser radiation (HeNe; 632.8 nm), pulsed infrared laser radiation (IR; 904 nm), and the two combined on skin wound healing in New Zealand white rabbits. Seventy-two rabbits received either (1) no exposure, (2) 1.65 J/cm2 HeNe, (3) 8.25 J/cm2 pulsed IR, or (4) both HeNe and IR together to one of two dorsal full-thickness skin wounds, daily, for 21 days. Wound areas were measured photographically at periodic intervals. Tissue samples were analyzed for tensile strength, and histology was done to measure epidermal thickness and cross-sectional collagen area. Significant differences were found in the tensile strength of all laser-treated groups (both the irradiated and nonirradiated lesion) compared to group 1. No differences were found in the rate of wound healing or collagen area. Epidermal growth was greater in the HeNe-lased area compared to unexposed tissue, but the difference was not significant. Thus, laser irradiation at 632.8 nm and 904 nm alone or in combination increased tensile strength during wound healing and may have released tissue factors into the systemic circulation that increased tensile strength on the opposite side as well.

  3. Thermal effects of transcranial near-infrared laser irradiation on rabbit cortex.

    PubMed

    Chen, Yongmei; De Taboada, Luis; O'Connor, Michael; Delapp, Scott; Zivin, Justin A

    2013-10-11

    Transcranial near-infrared laser therapy (TLT) improves stroke outcome in animal models. Adequate laser doses are necessary to exert therapeutic effects. However, applying higher laser energy may cause cortical tissue heating and exacerbate stroke injury. The objective of this study is to examine the thermal effect and safety of transcranial near-infrared laser therapy. Diode laser with a wavelength of 808 nm was used to deliver different power densities to the brain cortex of rabbits. Cortical temperature was monitored and measured using a thermal probe during the 2 min transcranial laser irradiation. Neuro-pathological changes were examined with histological staining 24 h after laser treatment. Transcranial laser irradiation for 2 min at cortical power densities of 22.2 and 55.6 mW/cm(2) with continuous wave (CW) did not increase cortical temperature in rabbits. With the same treatment regime, cortical power density at 111.1 mW/cm(2) increased brain temperature gradually by 0.5 °C over the 2 min exposure and returned to baseline values within 1-2 min post-irradiation. Separately, histological staining was evaluated after triple laser exposure of 22.2 mW/cm(2) CW and 111.1 mW/cm(2) pulse wave (PW) and showed normal neural cell morphology. The present study demonstrated that the TLT powers currently utilized in animal stroke studies do not cause cortical tissue heating and histopathological damage. Copyright © 2013 The Authors. Published by Elsevier Ireland Ltd.. All rights reserved.

  4. Craniocervical Pneumatization

    PubMed Central

    Quigley, Alan James; Shannon, Helen

    2013-01-01

    Craniocervical bony pneumatization is a rare finding, with limited numbers of cases reported in the literature. It is thought to be linked to Eustachian tube dysfunction and a ball valve mechanism, and has a link with recurrent Valsalva maneuvers. We report a case of pneumatization of the occiput, atlas (C1) and axis (C2) in a patient with extensive ENT (Ear, Nose and Throat) surgical history who presented following a fall. Plain film, CT and MRI images are presented. PMID:24421950

  5. The irradiation of rabbit sperm cells with He-Ne laser prevents their in vitro liquid storage dependent damage.

    PubMed

    Iaffaldano, Nicolaia; Rosato, Maria Pina; Paventi, Gianluca; Pizzuto, Roberto; Gambacorta, Mario; Manchisi, Angelo; Passarella, Salvatore

    2010-05-01

    The aim of the study was to investigate the effects of different energy doses of helium-neon (He-Ne) laser irradiation on both mitochondrial bioenergetics functions and functional quality of rabbit spermatozoa during 48 h of in vitro liquid storage at 15 degrees C. 11 rabbit semen pools were each divided into four aliquots: three of them were irradiated with He-Ne laser with different energy doses (3.96, 6.12 and 9.00 J/cm(2)) being the last control kept under the same experimental conditions without irradiation. Sperm motility, viability and acrosome integrity were monitored together with cytochrome c oxidase (COX) activity and the cell energy charge (EC) at 0, 24 and 48 h of storage. Irradiated samples stored for 24 and 48 h better maintained motility (P < 0.01), acrosome integrity (P < 0.01) and viability (P < 0.05) with respect to the control, particularly with the energy dose of 6.12 J/cm(2) that showed the most intense biostimulative effect. COX activity and EC were immediately increased by irradiation particularly in the treatments 6.12 and 9.00 J/cm(2) (P < 0.05), that maintained their levels higher with respect to the control after 48 h of storage (P < 0.01). COX activity of rabbit sperm cells was positively correlated with EC (P < 0.05), viability (P < 0.01) and acrosome integrity (P < 0.05) parameters. These results indicate that the effects of He-Ne laser irradiation on sperm cells are mediated through the stimulation of the sperm mitochondrial respiratory chain and that this effect plays a significant role in the augmentation of the rabbit sperm cells' capability to survive during liquid storage conditions.

  6. Damage threshold of in-vivo rabbit cornea by 2 μm laser irradiation

    NASA Astrophysics Data System (ADS)

    Chen, Bo; Oliver, Jeffery; Dutta, Soumak; Rylander, Grady H., III; Thomsen, Sharon L.; Welch, Ashley J.

    2007-02-01

    To support refinement of the Maximum Permissible Exposure (MPE) safety limits, a series of experiments were conducted in vivo on Dutch Belted rabbit corneas to determine corneal minimum visible lesion thresholds for 2.0 μm continuous-wave laser irradiation. Single pulse radiant exposures were made at specified pulse durations of 0.1 sec, 0.25 sec, 0.5 sec, 1.0 sec, 2.0 sec and 4.0 seconds for spot 1/e2 diameters of 1.17 mm and 4.02 mm. Lesions were placed in rows without overlap on rabbit cornea. The effect of each irradiation was evaluated within one minute post exposure and the final determination of lesion formation was made using a slit lamp one hour post exposure. Threshold lesions were defined as the presence of a superficial surface whitening one hour after irradiation. Probit analysis was conducted to estimate the dose for 50% probability (ED50) of laser-induced damage. Approximately 20 different radiant exposures were made for each exposure duration-spot size combination. At the threshold level, the diameters of barely visible opaque white lesions were smaller than the Gaussian 1/e2 beam diameter. In selected survival animals, most of the threshold lesions were still visible 24 hours after exposure. The average lesion radius was approximately 0.4 +/- 0.12 mm diameter for the 1.17 mm spot size and 1.0 +/- 0.20 mm diameter for the 4.02 mm spot size. The exposure duration dependence of threshold average radiant exposure was described by an empirical power law equation: Threshold radiant exposure[J/cm2] = a x exposure duration[s] b, experimentally derived coefficient a was 9.79 and b was 0.669 for the 1.17 mm spot diameter; values of a and b were 4.57 and 0.456 respectively for the 4.02 spot diameter. Based on the experimental data and the empirical power law, the safety factors which were defined as threshold radiant exposure divided by MPE values were predicted for the 2.0 μm wavelength at various exposure durations and spot diameters. The minimum limit of

  7. Effects of low-energy He-Ne laser irradiation on posttraumatic degeneration of adult rabbit optic nerve

    SciTech Connect

    Schwartz, M.; Doron, A.; Erlich, M.; Lavie, V.; Benbasat, S.; Belkin, M.; Rochkind, S.

    1987-01-01

    Axons of the mammalian peripheral and central nervous systems degenerate after nerve injury. We have recently found that He-Ne laser irradiation may prevent some of the consequences of the injury in peripheral nerves of mammals. In the present study, the efficacy of the laser in treating injured neurons of the mammalian CNS was tested. Optic nerves of adult rabbits were exposed daily for 8-14 days to He-Ne laser irradiation (14 min, 15 mW) through the overlying muscles and skin. As a result of this treatment, the injured nerves maintained their histological integrity, which is invariably lost in injured mammalian CNS neurons.

  8. A Rabbit Irradiation Platform for Outcome Assessment of Lung Stereotactic Radiosurgery

    SciTech Connect

    Cai Jing; Mata, Jaime F.; Orton, Matthew D.; Hagspiel, Klaus D.; Mugler, John P.; Larner, James M.; Sheng Ke; Read, Paul W.

    2009-04-01

    Purpose: To evaluate a helical tomotherapy-based rodent radiosurgery platform that reproduces human image-guided radiosurgery treatment to study radiobiologic effects of stereotactic radiosurgery on lung tissues using functional magnetic resonance imaging (MRI). Methods and Materials: Hypofractionated radisourgery (20 Gy x 3) was delivered to the right lung of three New Zealand rabbits using Helical TomoTherapy with MVCT image guidance. Contrast-enhanced MR perfusion, hyperpolarized helium-3 MR ventilation, and CT were obtained before radiation and monthly for 4 months after radiation. All MRI was performed on a 1.5-T whole-body scanner with broad-band capabilities. Results: Precise dose delivery to 1.6 cc of the lower right lung was achieved without additional immobilization. No deficits were detected at baseline with respect to perfusion and ventilation. Lung perfusion deficits in the irradiated lung regions began at 2 months after radiation and worsened with time. No ventilation deficits were observed after radiation. Decrease in lung CT density in irradiated regions was observed after radiation, but the changes were less significant than those in perfusion MRI. Conclusions: We demonstrated that highly conformal radiation can be reproducibly delivered to a small volume of rodent lung on a widely available clinical unit. The radiation-induced lung injury can be detected as early as 2 months after radiation with perfusion MRI. The primary pattern of injury agrees with previously reported endothelial damage to radiosurgical radiation doses. This experimental design provides a cost-effective methodology for producing radiosurgical injuries in rodents that reproduces current human treatments for studying radiation injury and agents that might affect it.

  9. Shape retention in porcine and rabbit nasal septal cartilage using saline bath immersion and Nd:YAG laser irradiation.

    PubMed

    Wright, Ryan; Protsenko, Dmitry E; Diaz, Sergio; Ho, Kevin; Wong, Brian

    2005-09-01

    The process of altering the shape of cartilage using heat has been referred to as thermoforming, and presents certain clinical benefits in reconstructive surgical procedures within the head and neck. Thermoforming allows cartilage in the upper airway and face to be reshaped without the use of classic surgical maneuvers such as carving, morselizing, or suturing. The goal of this study was to determine the dependence of cartilage shape change on both temperature and laser dosimetry using two thermoforming methods: saline bath immersion and laser irradiation. Ex-vivo rabbit and porcine nasal septal cartilages were mechanically deformed and reshaped using the two thermoforming methods. With saline bath immersion using rabbit cartilage, each specimen was deformed by securing it to a small copper tube (outer diameter 8 mm) using dental bands. For porcine cartilage immersed in a saline bath, each sample was mechanically deformed between two pieces of wire mesh attached to a semicircular acrylic block. With both porcine and rabbit cartilage, the specimen and apparatus were then immersed in a hot saline bath for time intervals varying from 20 and 320 seconds and at constant temperatures between 62 and 74 degrees C. In laser reshaping, the cartilage specimens were mechanically deformed on a jig and consecutively irradiated with an Nd:YAG laser (lambda = 1.32 microm) in several spots for 6-16 seconds and irradiances of 10.2-40.7 W/cm2 per spot. After either saline bath heating or irradiation, cartilage specimens were immersed in room temperature saline for 15 minutes, then upon removal from the jig the length between the ends of each specimen was measured in order to calculate the resulting bend angle. The transition zone for cartilage reshaping was defined as where a significant increase in bend angle was observed between consecutive times of immersion/irradiation at the same temperature/irradiance. For the saline bath experiments, the transition zone was observed between 59

  10. Investigation of carbohydrate and protein metabolism in the digestive organs of the rabbit under the combined influence of vibration, acceleration and irradiation

    NASA Technical Reports Server (NTRS)

    Yuy, R. I.

    1975-01-01

    During spaceflight, the organism is subjected to the influence of various extremal factors such as acceleration, vibration, irradiation, etc. The study of the influence of these factors on metabolism, especially carbohydrate and protein metabolism, in young rabbits is of great significance in simulation experiments. Dynamic factors and irradiation, depending on dose and duration, lead to reduced RNA and protein metabolism.

  11. Investigation of carbohydrate and protein metabolism in the digestive organs of the rabbit under the combined influence of vibration, acceleration and irradiation

    NASA Technical Reports Server (NTRS)

    Yuy, R. I.

    1975-01-01

    During spaceflight, the organism is subjected to the influence of various extremal factors such as acceleration, vibration, irradiation, etc. The study of the influence of these factors on metabolism, especially carbohydrate and protein metabolism, in young rabbits is of great significance in simulation experiments. Dynamic factors and irradiation, depending on dose and duration, lead to reduced RNA and protein metabolism.

  12. Differential analysis of D-{beta}-Asp-containing proteins found in normal and infrared irradiated rabbit lens

    SciTech Connect

    Takata, Takumi; Shimo-Oka, Tadashi; Kojima, Masami; Miki, Kunio; Fujii, Noriko . E-mail: nfujii@HL.rri.kyoto-u.ac.jp

    2006-05-26

    Although proteins are generally composed of L-{alpha}-amino acids, D-{beta}-aspartic acid (Asp)-containing proteins have been reported in various elderly tissues. Our previous study detected several D-{beta}-Asp-containing proteins in a rabbit lens derived from epithelial cell line by Western blot analysis of a 2D-gel using a polyclonal antibody that is highly specific for D-{beta}-Asp-containing proteins. The identity of each spot was subsequently determined by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry and the Ms-Fit online database searching algorithm. In this study, we discovered novel D-{beta}-Asp-containing proteins from rabbit lens. The results indicate that {beta}-crystallin A3, {beta}-crystallin A4, {beta}-crystallin B1, {beta}-crystallin B2, {beta}-crystallin B3, {gamma}-crystallin C, {gamma}-crystallin D, and {lambda}-crystallin in rabbit lens contain D-{beta}-Asp residues. Furthermore, the occurrence of D-{beta}-Asp residues increases with infrared ray (IR) irradiation. Additionally, some D-{beta}-Asp-containing proteins only appear after IR irradiation. One such protein is the {alpha}-enolase, which shows homology to {tau}-crystallin.

  13. Axon reflex in ocular injury: sensory mediation of the response of the rabbit eye to laser irradiation of the iris.

    PubMed

    Butler, J M; Unger, W G; Cole, D F

    1980-10-01

    Laser irradiation of the rabbit iris produces an injury response consisting of prolonged miosis, uveal vasodilation and a transient rise of intraocular pressure (IOP) accompanied by a breakdown of the blood-aqueous barrier. This response has hitherto been attributed partly to prostaglandin (PG) mediation and partly to mediation by a non-cholinergic nervous pathway thought to be sensory in fuction. Responses of the rabbit eye to laser irritation were examined at specified intervals after diathermic coagulation of the epigasserian nerve tract. Both the intensity of the pupillary constriction and the increase in IOP were almost unaltered at 90 minutes but progressively decreased until at 4 days there was essentially no response to high energy laser irradiation in the denervated eye. It was evident that manifestation of the response is largely dependent upon the presence of intact and functional sensory nerves, and it is proposed that endogenous PGs exert some, if not all of their effects via sensory nerve endings. It is suggested that those terminals which are directly stimulated, whether by laser irradiation or by PGs formed during the injury, release some mediator to cause pupillary constriction. From thes terminals impulses pass orthodromically and antidromically by axon reflex to release further mediator from terminals in the region of the ciliary vessels or the major arterial circle. In this way the response is propagated and augmented.

  14. Effects of low-intensity laser irradiation on the apoptosis of rabbit vascular smooth muscle cells in culture

    NASA Astrophysics Data System (ADS)

    Li, S. D.; Chen, P.; Zhang, C. P.; Wen, J. X.; Liang, J.; Kang, H. X.; Gao, R. L.; Fu, X. B.

    2011-11-01

    Restenosis is a major complication after coronary intervention therapy. Excessive proliferation of vascular smooth muscle cells (VSMCs) and a decline in their apoptosis, which eventually leads to excessive neointimal thickening in coronary arteries, are the main causes of restenosis. Induction of the apoptosis of VSMCs and inhibition of excessive proliferation of VSMCs are therefore crucial for the prevention of restenosis, and low-intensity laser irradiation of coronary arteries may play a promising role in keeping this in balance. In this study, we used in vitro cultured rabbit VSMCs to investigate the effects of low-intensity laser irradiation at a wavelength of 532 nm on the apoptosis of VSMCs via morphological observation and molecular biology. The results showed that apoptotic bodies and obvious intranuclear apoptosis-positive particles formed within VSMCs 24 h after laser irradiation, suggesting that low-intensity laser irradiation at certain doses can inhibit the proliferation of VSMCs by promoting their apoptosis. This experiment provides evidences for further animal experiments and clinical trials on prevention and treatment of restenosis by intracoronary low-intensity laser irradiation at a wavelength of 532 nm.

  15. The effect of topical dexamethasone and preoperative beta irradiation on a model of glaucoma fistulizing surgery in the rabbit

    SciTech Connect

    Miller, M.H.; Grierson, I.; Unger, W.G.; Hitchings, R.A. )

    1990-01-01

    We studied the effect of topical dexamethasone (1%) and preoperative beta irradiation on a model of glaucoma fistulizing surgery in the rabbit. Intraocular pressure and gross facility of aqueous outflow following surgery were not influenced by either treatment, although blebs persisted longer in the irradiated eyes. Steroids reduced clinically observable inflammation as well as the number of inflammatory cells identifiable by microscopy. Fibroblast production temporarily slowed, and ultrastructural examination demonstrated lipid-filled vacuoles and dilated mitochondria in these eyes. Also, the scar was thinner at 24 days. Beta irradiation delayed wound healing and the scar was thinner in the early postoperative stages, but the light microscopic appearance of the scar was unaltered at 59 days. Inflammation was more pronounced initially, with abundant fibrin in the wound. Recovery of the conjunctival epithelium was delayed. The delay in fibroblast recruitment and wound contraction, the thinner scar tissue, and the increased survival of the bleb are all factors that suggest that beta irradiation may be a useful adjunct to glaucoma surgery.

  16. Assessment of the neutralizing potency of antisera raised against native and γ-irradiated Naja nigricollis (black-necked spitting cobra) venom in rabbits, concerning its cardiotoxic effect.

    PubMed

    Abdou, F; Denshary, E E; Shaaban, E; Mohamed, M

    2017-01-01

    The present study was designed to prepare a specific safe antiserum for Naja nigricollis using γ-irradiated (1.5KGy and3KGy) venoms. Rabbits were used for active immunization using irradiated venoms (1.5 and 3 kGy) as a toxoid, mice were used for determination of LD50 post immunization and the rats were used for neutralization of the cardiotoxic effect of venom. Results of the immunodiffusion test indicated that the sera of rabbits raised against non-irradiated, 1.5- and 3-kGy γ-irradiated venom, had the same results of precipitin bands. A significant inhibition of phospholipase A2 activities was obtained when neutralized with native, γ-irradiated (1.5KGy and3KGy) venoms. On the other hand, preincubation of the venom ½ LD50 (0.154 mg/kg i.p.) with each antiserum (non-irradiated or irradiated venom) at 37°C for 1 h in a ratio (1:4) produced a significant reduction in the values of creatine kinase and creatine kinase isoenzyme-MB. However, significant elevation in aspartate aminotransferase level and no change in lactate dehydrogenase level were observed. So the results of this study indicated that the irradiated venom treatment reduces the cardiotoxic effect of venom in immunized immunization animals for preparing vaccines.

  17. Pneumatic Valve Operated by Multiplex Pneumatic Transmission

    NASA Astrophysics Data System (ADS)

    Nishioka, Yasutaka; Suzumori, Koichi; Kanda, Takefumi; Wakimoto, Shuichi

    A pneumatic system has several advantages, which are cheapness, lightweight, and reliability to human and environment. These advantages are adapted to some research areas, such as industrial lines, medical and nursing cares, and rehabilitation tools. However, the pneumatic system needs several devices; compressor, air tube, and control valve. This research aim to downsize pneumatic system. In this paper, a new method of multiplex pneumatic transmission for multi-pneumatic servo system is proposed. The valve for this system consists of two vibrators supported by springs, which was designed with simple and cheap structure. The working principle of the valve is vibrators resonance from multiplex pneumatic transmission and it is possible to work as ON/OFF valves without electric wire. Dynamic simulation was used to confirm the working principle of the resonance driving system. A prototype device confirming the principle was designed and developed based on the simulation. The experiments show that this new control system works very well to control two separated valves through single pneumatic tube.

  18. High resolution scanning electron microscopy of rabbit corneal endothelium to show effects of UV-visible irradiation in the presence of chlorpromazine

    SciTech Connect

    Lea, P.J.; Hollenberg, M.J.; Menon, I.A.; Temkin, R.J.; Persad, S.D.; Basu, P.K. )

    1989-01-01

    The ultrastructure of rabbit cornea endothelial cells was examined by scanning electron microscopy (SEM) in freeze-cleaved corneas using a Hitachi S-570 scanning electron microscope in the high resolution mode (HRSEM). In order to study phototoxic effects in vitro, rabbit corneas (experimental) were cultured as organ culture in the presence of 5 micrograms/ml chlorpromazine (CPZ) and irradiated. For comparison, control 1 corneas were not irradiated but incubated in the dark without CPZ in the medium; control 2 corneas were also kept in the dark but in the presence of CPZ; control 3 corneas were irradiated with no CPZ in the medium. Cellular damage was not seen in the three types of control corneas, but in the experimental corneas the endothelial cells showed extensive disruption of the cell membrane and some deterioration of the intracellular components. Our study confirmed that HRSEM is a satisfactory new technique for visualizing damage of the intracellular organelles of corneal endothelium.

  19. Converging Stereotactic Radiotherapy Using Kilovoltage X-Rays: Experimental Irradiation of Normal Rabbit Lung and Dose-Volume Analysis With Monte Carlo Simulation

    SciTech Connect

    Kawase, Takatsugu; Kunieda, Etsuo Deloar, Hossain M.; Tsunoo, Takanori; Seki, Satoshi; Oku, Yohei; Saitoh, Hidetoshi; Saito, Kimiaki; Ogawa, Eileen N.; Ishizaka, Akitoshi; Kameyama, Kaori; Kubo, Atsushi

    2009-10-01

    Purpose: To validate the feasibility of developing a radiotherapy unit with kilovoltage X-rays through actual irradiation of live rabbit lungs, and to explore the practical issues anticipated in future clinical application to humans through Monte Carlo dose simulation. Methods and Materials: A converging stereotactic irradiation unit was developed, consisting of a modified diagnostic computed tomography (CT) scanner. A tiny cylindrical volume in 13 normal rabbit lungs was individually irradiated with single fractional absorbed doses of 15, 30, 45, and 60 Gy. Observational CT scanning of the whole lung was performed every 2 weeks for 30 weeks after irradiation. After 30 weeks, histopathologic specimens of the lungs were examined. Dose distribution was simulated using the Monte Carlo method, and dose-volume histograms were calculated according to the data. A trial estimation of the effect of respiratory movement on dose distribution was made. Results: A localized hypodense change and subsequent reticular opacity around the planning target volume (PTV) were observed in CT images of rabbit lungs. Dose-volume histograms of the PTVs and organs at risk showed a focused dose distribution to the target and sufficient dose lowering in the organs at risk. Our estimate of the dose distribution, taking respiratory movement into account, revealed dose reduction in the PTV. Conclusions: A converging stereotactic irradiation unit using kilovoltage X-rays was able to generate a focused radiobiologic reaction in rabbit lungs. Dose-volume histogram analysis and estimated sagittal dose distribution, considering respiratory movement, clarified the characteristics of the irradiation received from this type of unit.

  20. Update on pneumatic retinopexy.

    PubMed

    Mandelcorn, Efrem D; Mandelcorn, Mark S; Manusow, Joshua S

    2015-05-01

    Pneumatic retinopexy is an effective, cost-efficient procedure for retinal detachment repair. We review the history, indications, procedure, outcomes, economics, and trends regarding this in-office procedure. Pneumatic retinopexy is classically performed in patients with small, superior retinal breaks, but these indications are expanding, with good results. Retinal reattachment rates with pneumatic retinopexy vary from 60% to 91% depending upon patient selection. Pneumatic retinopexy is less costly to perform than scleral buckling and pars plana vitrectomy and avoids many of the complications associated with these procedures. Despite these good results, recent data suggest that the use of pneumatic retinopexy is on the decline. Recent review of the literature and our own personal experience using pneumatic retinopexy in selected cases of retinal detachment indicate that it is an effective and inexpensive procedure that avoids many of the complications that are associated with other retinal reattachment procedures.

  1. Ultraviolet-C irradiation to titanium implants increases peri-implant bone formation without impeding mineralization in a rabbit femur model.

    PubMed

    Yamazaki, Makoto; Yamada, Masahiro; Ishizaki, Ken; Sakurai, Kaoru

    2015-05-01

    Volume and bone quality of peri-implant supporting bone, in particular, at implant neck region, as well as bone-implant contact ratio, is important for long-term stability of implants. Ultraviolet-C (UVC) irradiation is known to enhance the osseointegration capability of titanium implants. However, the histological determination was performed only on a rat model, but not pre-clinical animal model such as a rabbit model. The purpose of this study was to determine the effects of UVC irradiation on titanium implants on the volume and mineral density of peri-implant supporting bone formation in a rabbit femur model. Acid-etched pure titanium screw implants with or without 3 mW/cm2 UVC irradiation for 48 h were placed in rabbit femur diaphyses. Peri-implant bone tissue formation was analyzed at 3 and 8 weeks post-operatively by histology and micro-CT-based bone morphometry after calibration with hydroxyl apatite phantoms. UVC pre-irradiated implants accumulated a higher density of cells and thicker and longer bone tissue attachments that continued into the inner basic lamellae of the surface of existing cortical bone at 3 and 8 weeks than the implants without irradiation. Although the bone mineral density around both implants was equivalent to that of the existing cortical bone, bone volume was greater with UVC pre-irradiation in two-thirds or more of the apical region throughout the observation period. These results indicate that UVC treatment increased the volume of cortical-like bone tissue in the coronal region of titanium implants without deterioration of bone mineral density.

  2. The Role of IgG Antibodies from Irradiated Cercaria-Immunized Rabbits in the Passive Transfer of Immunity to Schistosoma Mansoni-Infected Mice

    DTIC Science & Technology

    1992-01-01

    RABBITS IN TilE PASSIVE TRANSFER Of’ IMMUNITY TO SCHISTOSOMA MANSONI -INFECTI3D MICE BY Beverly L. Mangold and David A. Dean U.S. NAVAL MEDICAL RESEARCH...kilorads of gamma irradiation passively provided partial immunity against Schistosoma mansoni challenge in C57BI/6J mice. These mice exhibited...previously shown that par- compared with control rats. and naive rats re- tial immunity against Schistosoma mansoni in- ceiving serum from KLH-immunized

  3. Topical Administration of the Mitochondrial PTP Opening Inhibitor CoQ10 Prevents Apoptotic Cell Death Induced by UVC-Irradiation in Rat's Corneas and Rabbit's Retinas

    NASA Astrophysics Data System (ADS)

    Papucci, Laura; Witort, Ewa; Schiavone, Nicola; Donnini, Martino; Lapucci, Andrea; Lulli, Matteo; Lazzarano, Stefano; Simoncini, Madine; Mazzoni, Tiziano; Falciani, Piergiuseppe; Capaccioli, Sergio

    2008-06-01

    We have previously demonstrated in vitro that ubiquitous free radical scavenger coenzyme Q10 prevents keratocyte apoptosis induced by excimer laser irradiation more efficiently than other antioxidants. We showed that its anti apoptotic property is independent of its free radical scavenging ability and is related to direct inhibition of PTP (permeability transition pore) opening and mitochondrial depolarization. Here, we demonstrate in vivo, that CoQ10 can efficiently protect rat's corneas and rabbit's retinas irradiated with UVC. Therefore, we propose application of CoQ10 as countermeasure to prevent micro radiation-induced eye damage during interplanetary space exploration.

  4. Basic Pneumatics. Instructor's Guide.

    ERIC Educational Resources Information Center

    Fessehaye, Michael

    This instructor's guide is designed for use by industrial vocational teachers in teaching a course on basic pneumatics. Covered in the individual units are the following topics: an introduction to pneumatics (including the operation of a service station hoist); fundamentals and physical laws; air compressors (positive displacement compressors;…

  5. Rotary pneumatic valve

    DOEpatents

    Hardee, Harry C.

    1991-01-01

    A rotary pneumatic valve which is thrust balanced and the pneumatic pressure developed produces only radial loads on the valve cylinder producing negligible resistance and thus minimal torque on the bearings of the valve. The valve is multiplexed such that at least two complete switching cycles occur for each revolution of the cylinder spindle.

  6. Basic Pneumatics. Instructor's Guide.

    ERIC Educational Resources Information Center

    Fessehaye, Michael

    This instructor's guide is designed for use by industrial vocational teachers in teaching a course on basic pneumatics. Covered in the individual units are the following topics: an introduction to pneumatics (including the operation of a service station hoist); fundamentals and physical laws; air compressors (positive displacement compressors;…

  7. Effect of low-level laser therapy irradiation and Bio-Oss graft material on the osteogenesis process in rabbit calvarium defects: a double blind experimental study.

    PubMed

    Rasouli Ghahroudi, Amir Alireza; Rokn, Amir Reza; Kalhori, Katayoun A M; Khorsand, Afshin; Pournabi, Alireza; Pinheiro, A L B; Fekrazad, Reza

    2014-05-01

    This study aims to assess the effect of low-level laser therapy (LLLT) irradiation and Bio-Oss graft material on the osteogenesis process in the rabbit calvarium defects. Twelve white male New Zealand rabbits were included in this study. Four 8-mm diameter identical defects were prepared on each rabbit's calvarium. One site was left as an untreated control (C), the second site was filled with Bio-Oss (B), the third site was treated with laser irradiation (L), and the fourth site treated with Bio-Oss and laser irradiation (B + L). In the laser group, a diode laser (wavelength 810 nm, output power 300 mW, irradiation mode CW, energy density 4 J/cm2) was applied immediately after surgery and then one other day for the next 20 days. After 4 and 8 weeks, the animals were sacrificed and histological and histomorphometric examinations were performed and the data were subjected to Friedman and repeated measurements ANOVA tests. Significant differences were not found regarding inflammation severity, foreign body reactions, and vitality of newly formed bone on 4th and 8th week after operation. The mean amount of new bone was 15.83 and 18.5% in the controls on the 4th and 8th week; 27.66 and 25.16% in the laser-irradiated group; 35.0 and 41.83% in Bio-Oss and 41.83 and 47.0% in the laser + Bio-Oss treated specimens with significant statistical differences (p <0.05). Application of LLLT in combination with Bio-Oss® can promote bone healing. Therefore, LLLT may be clinically beneficial in promoting bone formation in skeletal defects.

  8. The In Vivo Bone Response of Ultraviolet-Irradiated Titanium Implants Modified with Spontaneously Formed Nanostructures: An Experimental Study in Rabbits.

    PubMed

    Shen, Jianwei; Liu, Jianhu; Chen, Xiaoyi; Wang, Xiaoxiang; He, Fuming; Wang, Huiming

    2016-01-01

    Acid etching in conjunction with storage in an aqueous solution can induce nanostructures forming spontaneously on titanium surfaces, but an inevitable biologic degradation is suspected to accompany the evolution of nanostructures. The aim of this study was to investigate whether ultraviolet (UV) irradiation is effective to solve this problem and further enhance the bioactivity. Surface characteristics of five groups of titanium implants (SLAnew, SLAold, modSLA, UV-SLA, and UV-modSLA) and their in vivo bone response were analyzed in this study. The surface characteristics were evaluated with contact angle measurements, scanning electron microscopy, and x-ray photon spectroscopy. A total of 160 implants (32 for each group) were inserted into the tibial metaphyses and femoral condyles of 40 rabbits. After 3 and 6 weeks, the rabbits were euthanized for removal torque tests and histomorphometric analysis. Spontaneously formed nanostructures were observed on water-stored surfaces with a size of approximately 15 nm in diameter, and an inevitable contamination of hydrocarbons accompanied the evolution of nanostructures. UV irradiation effectively eliminated hydrocarbon contamination that accompanied nanostructure evolution. UV-modSLA implants showed the highest removal torque value, and UV-irradiated implants exhibited higher bone-to-implant contact and bone area. UV irradiation can effectively eliminate the hydrocarbon contamination accompanying the evolution of nanostructures and further enhance the osseointegration. Nanostructures and UV treatment have combined effects in enhancing the interfacial strength between titanium and bone, while UV photofunctionalization has much more overwhelming effects on histologic and histomorphometric performance.

  9. Inexpensive Dramatic Pneumatic Lift

    NASA Astrophysics Data System (ADS)

    Morse, Robert A.

    2017-09-01

    Various experiments and demonstrations relate air pressure and air pressure difference to force and area. Carpenter and Minnix describe a large-scale pneumatic lift in which a person sitting on a board atop a plastic garbage bag is lifted when the bag is connected to the exhaustport of a vacuum cleaner, which easily lifts the person. This article describes the construction and use of an inexpensive hand-held pneumatic lift to demonstrate the same principle.

  10. Pneumatic sample-transfer system for use with the Lawrence Livermore National Laboratory rotating target neutron source (RTNS-I)

    SciTech Connect

    Williams, R.E.

    1981-07-01

    A pneumatic sample-transfer system is needed to be able to rapidly retrieve samples irradiated with 14-MeV neutrons at the Rotating Target Neutron Source (RTNS-I). The rabbit system, already in place for many years, has been refurbished with modern system components controlled by an LSI-11 minicomputer. Samples can now be counted three seconds after an irradiation. There are many uses for this expanded 14-MeV neutron activation capability. Several fission products difficult to isolate from mixed fission fragments can be produced instead through (n,p) or (n,..cap alpha..) reactions with stable isotopes. Mass-separated samples of Nd, Mo, and Se, for example, can be irradiated to produce Pr, Nb, and As radionuclides sufficient for decay scheme studies. The system may also be used for multielement fast-neutron activation analysis because the neutron flux is greater than 2 x 10/sup 11/ n/cm/sup 2/-sec. Single element analyses of Si and O are also possible. Finally, measurements of fast-neutron cross sections producing short-lived activation products can be performed with this system. A description of the rabbit system and instructions for its use are presented in this report.

  11. The influence of intravenous laser irradiation of blood on some metabolic and functional parameters in intact rabbits and experimental cerebral ischaemia

    NASA Astrophysics Data System (ADS)

    Nechipurenko, N.; Vasilevskaya, L.; Musienko, J.; Maslova, G.

    2007-07-01

    It has been studied the intravenous laser irradiation of blood (ILIB) influence with helium-neon laser (HNL) of 630 nm wavelength on some of lipid peroxidation (LPO) and antioxidant system (AOS) findings, aside-base status (ABS) and blood oxygen transport (BOT), state of dermal microhaemodynamics (MGD) in the intact rabbits and after modeling of local ischemia of brain (LIB). Depending on conditions of organism functioning (norm or brain ischaemia) ILIB has resulted in stimulating or normalizing effects on the whole metabolic and microhaemocirculation processes which had been studied during our investigation. It is discussed the mechanisms of pathogenetic directivity of ILIB influence in cerebral ischaemia

  12. Combination of BMP-2-releasing gelatin/β-TCP sponges with autologous bone marrow for bone regeneration of X-ray-irradiated rabbit ulnar defects.

    PubMed

    Yamamoto, Masaya; Hokugo, Akishige; Takahashi, Yoshitake; Nakano, Takayoshi; Hiraoka, Masahiro; Tabata, Yasuhiko

    2015-07-01

    The objective of this study is to evaluate the feasibility of gelatin sponges incorporating β-tricalcium phosphate (β-TCP) granules (gelatin/β-TCP sponges) to enhance bone regeneration at a segmental ulnar defect of rabbits with X-ray irradiation. After X-ray irradiation of the ulnar bone, segmental critical-sized defects of 20-mm length were created, and bone morphogenetic protein-2 (BMP-2)-releasing gelatin/β-TCP sponges with or without autologous bone marrow were applied to the defects to evaluate bone regeneration. Both gelatin/β-TCP sponges containing autologous bone marrow and BMP-2-releasing sponges enhanced bone regeneration at the ulna defect to a significantly greater extent than the empty sponges (control). However, in the X-ray-irradiated bone, the bone regeneration either by autologous bone marrow or BMP-2 was inhibited. When combined with autologous bone marrow, the BMP-2 exhibited significantly high osteoinductivity, irrespective of the X-ray irradiation. The bone mineral content at the ulna defect was similar to that of the intact bone. It is concluded that the combination of bone marrow with the BMP-2-releasing gelatin/β-TCP sponge is a promising technique to induce bone regeneration at segmental bone defects after X-ray irradiation.

  13. Induction of skin papillomas in the rabbit, Oryctologus cuniculus, by bites of a blood-sucking insect, Cimex lectularius, irradiated by gamma rays

    SciTech Connect

    el-Mofty, M.M.; Sakr, S.A.; Younis, M.W. )

    1989-11-01

    Bed bugs, Cimex lectularius, irradiated with gamma rays were allowed to suck blood from shaved areas of the skin of rabbits, Oryctolagus cuniculus, 2 times/week for 5 months and then once weekly for another 5 months. This significantly induced the formation of skin papillomas and sweat gland hyperplasia in five out of nine experimental animals. It is speculated that the saliva of the irradiated bugs was activated by gamma rays and was responsible for the induction of skin papillomas. Because bed bugs play a significant role in the transmission of virus, it is also speculated that there is a virus in the saliva of bugs; this virus may be activated by gamma radiation and causes the development of papillomas in the skin.

  14. Pneumatic soil removal tool

    DOEpatents

    Neuhaus, John E.

    1992-01-01

    A soil removal tool is provided for removing radioactive soil, rock and other debris from the bottom of an excavation, while permitting the operator to be located outside of a containment for that excavation. The tool includes a fixed jaw, secured to one end of an elongate pipe, which cooperates with a movable jaw pivotably mounted on the pipe. Movement of the movable jaw is controlled by a pneumatic cylinder mounted on the pipe. The actuator rod of the pneumatic cylinder is connected to a collar which is slidably mounted on the pipe and forms part of the pivotable mounting assembly for the movable jaw. Air is supplied to the pneumatic cylinder through a handle connected to the pipe, under the control of an actuator valve mounted on the handle, to provide movement of the movable jaw.

  15. Pneumatic soil removal tool

    DOEpatents

    Neuhaus, J.E.

    1992-10-13

    A soil removal tool is provided for removing radioactive soil, rock and other debris from the bottom of an excavation, while permitting the operator to be located outside of a containment for that excavation. The tool includes a fixed jaw, secured to one end of an elongate pipe, which cooperates with a movable jaw pivotably mounted on the pipe. Movement of the movable jaw is controlled by a pneumatic cylinder mounted on the pipe. The actuator rod of the pneumatic cylinder is connected to a collar which is slidably mounted on the pipe and forms part of the pivotable mounting assembly for the movable jaw. Air is supplied to the pneumatic cylinder through a handle connected to the pipe, under the control of an actuator valve mounted on the handle, to provide movement of the movable jaw. 3 figs.

  16. Influence of intravascular low level He-Ne laser irradiation on iNOS, total-NOS, and ET-1 in acute spinal cord-injured rabbits

    NASA Astrophysics Data System (ADS)

    Yin, Zhenchun; Dong, Yinghai; Zhu, Jing

    2005-07-01

    Objective To research the influence of intravascular low level Laser irradiation (ILLLI) on total NOS, iNOS, and ET-1 in spinal cord following acute spinal cord injury (ASCI), and discuss the protective effects of ILLLI on neurons .Methods 72 rabbits were randomly divided into 3 groups: treatment group, injury group and control group. In treatment group and injury group, after laminectomy at the level of T-13, ASCI was performed by using Allen"s method with slight modification (6g×10cm) on rabbits. After injury, rabbits were treated immediately with He-Ne laser (power 5 mW, 1 hour per day for 10 days). At the day of 10th after treatment, total-NOS, iNOS, and ET-1 in spinal cord tissues were measured. Results The expression level of total-NOS, iNOS, and ET-1 in spinal cord in injury group were significantly higher than those in control group (P<0.05), while after ILLLI the level of these index in treatment group decreased statistically significantly compared with those in injury group (P<0.05). Conclusion ILLLI can significantly decrease the expression level of total-NOS, iNOS, and ET-1 in spinal cord. It indicates that ILLLI can relieve the overexpression of total-NOS, iNOS, and ET-1 ,and thus can perform protective effects on neurons in the course of secondary spinal cord injury (SSCI) following ASCI

  17. [Comparative analysis between sclera treated with glycerin and sclera treated with gamma irradiation, alkali and glycerin in the reconstruction of anophthalmic socket: experimental study in rabbits].

    PubMed

    Fernandes, José Byron Vicente Dias; Matayoshi, Suzana; Osaka, Junko Takano; Tolosa, Erasmo Castro Magalhães; Nunes, Tânia Pereira; Moura, Eurípedes da Mota

    2007-01-01

    To compare two sclera decontamination methods: treatment with glycerin versus treatment with gamma irradiation, alkali and glycerin, aiming to detect the clinical and histological alterations in rabbit anophthalmic sockets reconstructed with sclera-involved polymethylmethacrylate spheres. Thirty-nine New Zealand-breed rabbits were divided into two groups: group I, whose animals were submitted to enucleation of one eye and reconstruction with a polymethylmethacrylate sphere involved in glycerin-treated sclera; group II, where there was enucleation, and reconstruction performed with a polymethylmethacrylate sphere involved in sclera treated with gamma irradiation, alkali and glycerin. The two groups were observed at four moments, at 7, 21, 42 and 84 days after surgery. Preset times elapsed, the rabbits were euthanized, sockets were exenterated, the material was processed for embedment in paraffin, cut into 5 microm sections thick and stained with hematoxylin-eosin and Masson's trichrome techniques. The scleras were submitted to morphometric and semiquantitative analysis. Results were compared by Mann-Whitney's non-parametric test. Comparative analysis of vascularization of the surgical interface pointed out a significative difference in the evaluation done 21 days after the implant (P<0.001), with group II showing greater neovascularization. Comparison of the fibrous capsule thickness displayed a significative difference at moments corresponding to 21 days (P<0.001) and 42 days (P<0.001). At both moments, group II presented a thicker fibrous capsule than group I. Likewise, there was variation in sclera thickness, being thicker in group II, at the 21-day post-implant (P=0.003) moment, and at the 42-day moment (P=0.024), as well. Along the experimental period, when groups were analyzed we could observe statistically significative diminution of vascularization in the surgical interface, in group I, as well as in group II, at the moment of 7, 21, 42 and 84 days. When

  18. Pneumatic squirming robot based on flexible pneumatic actuator

    NASA Astrophysics Data System (ADS)

    Yang, Qinghua; Zhang, Libin; Bao, Guanjun; Ruan, Jian

    2005-12-01

    The design of a kind of pneumatic squirming robot is presented. It is based on the use of flexible pneumatic actuator. The flexible pneumatic actuator was made of caoutchouc. Its working principle is described. The structure, working principle, pneumatic and electrical control system of the pneumatic squirming robot are designed. All of the actuator's driving and squirming parts are composed of pneumatic elements. The vacuum osculums, which act as feet, are connected to the flexible pneumatic actuator. When the vacuum pumps operate, vacuum will be produced in the corresponding osculums, which can adsorb on the contacting surface and orient the robot. The actuator, operating under air pressure, drives the robot. By controlling the vacuum pumps and the actuator, straight and bending squirming of this robot can be obtained.

  19. Pneumatic stowing seals mines

    SciTech Connect

    Brezovec, D.

    1983-11-01

    A pneumatic stowing technique has been used in the US to seal entries to abandoned mines. Limestone mixed with dry cement or bentonite is blown into the opening. Sealing can be accomplished in much less time than with traditional concrete block/clay plug methods.

  20. Inexpensive Dramatic Pneumatic Lift

    ERIC Educational Resources Information Center

    Morse, Robert A.

    Various experiments and demonstrations relate air pressure and air pressure difference to force and area. Carpenter and Minnix describe a large-scale pneumatic lift in which a person sitting on a board atop a plastic garbage bag is lifted when the bag is connected to the exhaustport of a vacuum cleaner, which easily lifts the person. This article…

  1. Pneumatic osteoarthritis knee brace.

    PubMed

    Stamenović, Dimitrije; Kojić, Milos; Stojanović, Boban; Hunter, David

    2009-04-01

    Knee osteoarthritis is a chronic disease that necessitates long term therapeutic intervention. Biomechanical studies have demonstrated an improvement in the external adduction moment with application of a valgus knee brace. Despite being both efficacious and safe, due to their rigid frame and bulkiness, current designs of knee braces create discomfort and difficulties to patients during prolonged periods of application. Here we propose a novel design of a light osteoarthritis knee brace, which is made of soft conforming materials. Our design relies on a pneumatic leverage system, which, when pressurized, reduces the excessive loads predominantly affecting the medial compartment of the knee and eventually reverses the malalignment. Using a finite-element analysis, we show that with a moderate level of applied pressure, this pneumatic brace can, in theory, counterbalance a greater fraction of external adduction moment than the currently existing braces.

  2. Pneumatic conveyance apparatus and process

    DOEpatents

    Heckendorn, Frank M.; Matzolf, Athneal D.; Hera, Kevin R.

    2010-05-04

    A pneumatic nozzle capable of removing dry solid debris, liquids, and mixtures of solid and liquid waste is provided. The pneumatic nozzle uses a pressurized gas stream to push materials through the nozzle. The force of a pressurized gas stream provides a partial vacuum to allow material to be introduced into an opening of a nozzle via a slight suction force. Thereafter, individual particles and materials introduced into the pneumatic nozzle are pushed by a stream of pressurized gas through the nozzle.

  3. Computation of temperature elevation in rabbit eye irradiated by 2.45-GHz microwaves with different field configurations.

    PubMed

    Hirata, Akimasa; Watanabe, Soichi; Taki, Masao; Fujiwara, Osamu; Kojima, Masami; Sasaki, Kazuyuki

    2008-02-01

    This study calculated the temperature elevation in the rabbit eye caused by 2.45-GHz near-field exposure systems. First, we calculated specific absorption rate distributions in the eye for different antennas and then compared them with those observed in previous studies. Next, we re-examined the temperature elevation in the rabbit eye due to a horizontally-polarized dipole antenna with a C-shaped director, which was used in a previous study. For our computational results, we found that decisive factors of the SAR distribution in the rabbit eye were the polarization of the electromagnetic wave and antenna aperture. Next, we quantified the eye average specific absorption rate as 67 W kg(-1) for the dipole antenna with an input power density at the eye surface of 150 mW cm(-2), which was specified in the previous work as the minimum cataractogenic power density. The effect of administrating anesthesia on the temperature elevation was 30% or so in the above case. Additionally, the position where maximum temperature in the lens appears is discussed due to different 2.45-GHz microwave systems. That position was found to appear around the posterior of the lens regardless of the exposure condition, which indicates that the original temperature distribution in the eye was the dominant factor.

  4. Hydration and transparency of the rabbit cornea irradiated with UVB-doses of 0.25 J/cm(2) and 0.5 J/cm(2) compared with equivalent UVB radiation exposure reaching the human cornea from sunlight.

    PubMed

    Cejka, Cestmír; Ardan, Taras; Sirc, Jakub; Michálek, Jiří; Beneš, Jiří; Brůnová, Blanka; Rosina, Jozef

    2011-07-01

    Exposure of the cornea to UV radiation from sunlight evokes intraocular inflammation, photokeratitis. Photokeratitis is caused by UVB radiation. It is accompanied by changes of corneal hydration and light absorption. The aim of this study was to examine the effect of two UVB doses on corneal optics in rabbits and to compare these UVB doses with the equivalent exposure of UVB radiation reaching the human cornea from sunlight. Rabbit corneas were irradiated with a daily UVB dose of 0.25 J/cm(2) or 0.5 J/cm(2) for 4 days. One day after finishing the irradiations the rabbits were sacrificed and corneal light absorption measured using our spectrophotometrical method. Corneal hydration was examined using an ultrasonic Pachymeter every experimental day before the irradiation procedure and the last day before sacrificing the animals. Changes in corneal optics appeared after the repeated exposure of the cornea to a UVB dose of 0.25 J/ cm(2) and massively increased after the repeated exposure of the cornea to a UVB dose of 0.5 J/cm(2). The first significant changes in corneal hydration appeared after a single exposure of the cornea to a UVB dose of 0.25 J/cm(2). Changes in corneal hydration appeared after the exposure of the rabbit cornea to a single UVB dose equivalent to 2.6 hours of solar UVB radiation reaching the human cornea, as measured by UVB sensors embedded in the eyes of mannequin heads facing the sun on a beach at noon in July. Repeated exposure of the rabbit cornea to the same UVB dose evoked profound changes in corneal optics. Although comparison of experimental and outdoor conditions are only approximate, the results in rabbits point to the danger for the human eye from UVB radiation when short stays in sunlight are repeated for several consecutive days without UV protection.

  5. Reconstruction of irradiated bone segmental defects with a biomaterial associating MBCP+(R), microstructured collagen membrane and total bone marrow grafting: an experimental study in rabbits.

    PubMed

    Jégoux, Franck; Goyenvalle, Eric; Cognet, Ronan; Malard, Olivier; Moreau, Francoise; Daculsi, Guy; Aguado, Eric

    2009-12-15

    The bone tissue engineering models used today are still a long way from any oncologic application as immediate postimplantation irradiation would decrease their osteoinductive potential. The aim of this study was to reconstruct a segmental critical size defect in a weight-bearing bone irradiated after implantation. Six white New Zealand rabbits were immediately implanted with a biomaterial associating resorbable collagen membrane EZ(R) filled and micro-macroporous biphasic calcium phosphate granules (MBCP+(R)). After a daily schedule of radiation delivery, and within 4 weeks, a total autologous bone marrow (BM) graft was injected percutaneously into the center of the implant. All the animals were sacrificed at 16 weeks. Successful osseous colonization was found to have bridged the entire length of the defects. Identical distribution of bone ingrowth and residual ceramics at the different levels of the implant suggests that the BM graft plays an osteoinductive role in the center of the defect. Periosteum-like formation was observed at the periphery, with the collagen membrane most likely playing a role. This model succeeded in bridging a large segmental defect in weight-bearing bone with immediate postimplantation fractionated radiation delivery. This has significant implications for the bone tissue engineering approach to patients with cancer-related bone defects.

  6. Pneumatization of the sphenoid sinus.

    PubMed

    Terra, E R; Guedes, F R; Manzi, F R; Bóscolo, F N

    2006-01-01

    This paper describes a case of pneumatization of the sphenoid sinus in the pterygoid process and greater wing of the sphenoid bone, observed on a panoramic radiograph. Conventional radiographs and computerized tomography in axial and coronal sections confirmed the presence of the pneumatization of these structures.

  7. Pneumatic Pellet-Transporting System

    NASA Technical Reports Server (NTRS)

    Wood, George; Pugsley, Robert A.

    1992-01-01

    Pneumatic system transports food pellets to confined animals. Flow of air into venturi assembly entrains round pellets, drawing them from reservoir into venturi for transport by airflow. Pneumatic pellet-transporting system includes venturi assembly, which creates flow of air that draws pellets into system.

  8. The complication of pneumatic retinopexy.

    PubMed Central

    Hilton, G F; Tornambe, P E; Brinton, D A; Flood, T P; Green, S; Grizzard, W S; Hammer, M E; Leff, S R; Mascuilli, L; Morgan, C M

    1990-01-01

    There have been 26 published series with a total of 1274 detachments operated with pneumatic retinopexy. Eighty percent were reattached with a single procedure and 98% with reoperations. New breaks occurred in 13% and PVR in 4%. The complications published in 101 papers on pneumatic retinopexy in the last 5 years are analyzed as to frequency, prevention, management, and results. PMID:2095021

  9. Pneumatic Pellet-Transporting System

    NASA Technical Reports Server (NTRS)

    Wood, George; Pugsley, Robert A.

    1992-01-01

    Pneumatic system transports food pellets to confined animals. Flow of air into venturi assembly entrains round pellets, drawing them from reservoir into venturi for transport by airflow. Pneumatic pellet-transporting system includes venturi assembly, which creates flow of air that draws pellets into system.

  10. Rigidified pneumatic composites

    NASA Astrophysics Data System (ADS)

    van Dessel, Steven

    2000-10-01

    The overall objective of the research presented in this dissertation was to address global issues of adequate housing for all and the need for more sustainable human settlement. In order to address these, the emerging technology of rigidified pneumatic composites was investigated. Rigidified pneumatic composites (RPC) are defined as thin flexible membrane structures that are pneumatically deployed. After deployment, these structures harden due to chemical or physical change of the membrane. Because of this change, these structures do no longer require pneumatic pressure to maintain their shape. For the first time, a systematic listing of the various means available to develop polymeric materials useful in RPC technology is presented. With the aim to reduce the cost of RPC structures, a new material was proposed, developed, and evaluated. This material involved the formation of a semi-interpenetrating polymer network based on poly vinyl chloride and an acrylate based reactive plasticizer. The economical and environmental performances of RPC structures using this new material were assessed by means of a case study. In this study, the performance of RPC technology was compared with that of a typical wood light frame structure in the application of a small single-family house. The study indicated that the cost of ownership in present day value for the RPC structure was approximately 33% less than the cost of a comparable wood light frame structure. The study also indicated that significant environmental benefits exist with the use of RPC structures. It was found that the RPC structure used significantly less resources compared to the wood light frame structure. About 3.5 times less materials coming from non-renewable fossil resources, about 2.5 times less materials coming from trees, and about 19 times less materials coming from inorganic resources was used in the RPC structure relative to the wood light frame structure. The study concluded with pointing out various

  11. Pneumatic energy storage

    SciTech Connect

    Flowers, D.

    1995-09-19

    An essential component to hybrid electric and electric vehicles is energy storage. A power assist device could also be important to many vehicle applications. This discussion focuses on the use of compressed gas as a system for energy storage and power in vehicle systems. Three possible vehicular applications for which these system could be used are discussed in this paper. These applications are pneumatically driven vehicles, series hybrid electric vehicles, and power boost for electric and conventional vehicles. One option for a compressed gas system is as a long duration power output device for purely pneumatic and hybrid cars. This system must provide enough power and energy to drive under normal conditions for a specified time or distance. The energy storage system for this use has the requirement that it will be highly efficient, compact, and have low mass. Use of a compressed gas energy storage as a short duration, high power output system for conventional motor vehicles could reduce engine size or reduce transient emissions. For electric vehicles this kind of system could lengthen battery life by providing battery load leveling during accelerations. The system requirements for this application are that it be compact and have low mass. The efficiency of the system is a secondary consideration in this application.

  12. Common-path Fourier domain optical coherence tomography of irradiated human skin and ventilated isolated rabbit lungs

    NASA Astrophysics Data System (ADS)

    Popp, A.; Wendel, M.; Knels, L.; Knuschke, P.; Mehner, M.; Koch, T.; Boller, D.; Koch, P.; Koch, E.

    2005-08-01

    A compact common path Fourier domain optical coherence tomography (FD-OCT) system based on a broadband superluminescence diode is used for biomedical imaging. The epidermal thickening of human skin after exposure to ultraviolet radiation is measured to proof the feasibility of FD-OCT for future substitution of invasive biopsies in a long term study on natural UV skin protection. The FD-OCT system is also used for imaging lung parenchyma. FD-OCT images of a formalin fixated lung show the same alveolar structure as scanning electron microscopy images. In the ventilated and blood-free perfused isolated rabbit lung FD-OCT is used for real-time cross-sectional image capture of alveolar mechanics throughout tidal ventilation. The alveolar mechanics changing from alternating recruitment-derecruitment at zero positive end-expiratory pressure (PEEP) to persistent recruitment after applying a PEEP of 5 cm H2O is observed in the OCT images.

  13. Origin of postcranial skeletal pneumaticity in dinosaurs.

    PubMed

    Wedel, Mathew J

    2006-06-01

    The sauropodomorph Thecodontosaurus caducus and theropod Coelophysis bauri are the earliest known dinosaurs with postcranial skeletal pneumaticity. In both taxa, postcranial pneumatic features are confined to the cervical vertebrae. This distribution of pneumaticity in the skeleton is most consistent with pneumatization by diverticula of cervical air sacs similar to those of birds. Other hypotheses, including pneumatization by diverticula of the lungs, larynx and trachea, or cranial air spaces, are less well-supported.

  14. Pneumatic stowing seals mines

    SciTech Connect

    Brezovec, D.

    1983-11-01

    A mechanized technique to seal abandoned mines has been used successfully to close 13 openings at Duquesne Light Co.'s mined-out Warwick No. 2 mine, near Greensboro, Pa. The mechanized system, which uses a pneumatic stower and crushed limestone, closed the entries more economically and in less time than it would have taken to install traditional concrete block stopping and clay plug seals, according to John C. Draper. Draper, a mining engineer with Duquesne Light's coal department, was in charge of installing the Warwick seals in a Bureau of Mines-sponsored field test on the pneumatic sealing technique. The lowest estimated cost for installing conventional stopping and plug closures for the 13 Warwick openings was $225,000, says Draper, while the openings were closed using the mechanized system for $245,000. Draper says the newer stopping cost more in the instance because work was stopped often to gather information for the experiment. The experimental closures were installed in 38 days. The job would have taken at least 149 days if traditional closures were being installed, Draper say. To install a traditional concrete block/clay plug closure, the mine opening must be cleaned thoroughly and the roof must be supported for some 3 ft from the outside. Then a solid wall or stopping must be built 25 ft from the surface and the entry must be packed with clay to the surface. Much of this job requires workers to remain underground. In pneumatic stowing, 1 1/2-in. crushed limestone with fines is conveyed through a pipeline and into the mine opening under low air pressure. Watertight seals can be installed by blowing about 10 ft of rock into the opening against the top to act as roof support. Safety posts are installed and about 10 or 15 ft of mine entry is cleaned. About 2 in. of raw cement or bentonite is placed on the floor and limestone mixed with dry cement or bentonite is blown into the opening.

  15. Automatic irradiation control by an optical feedback technique for selective retina treatment (SRT) in a rabbit model

    NASA Astrophysics Data System (ADS)

    Seifert, Eric; Roh, Young-Jung; Fritz, Andreas; Park, Young Gun; Kang, Seungbum; Theisen-Kunde, Dirk; Brinkmann, Ralf

    2013-06-01

    Selective Retina Therapy (SRT) targets the Retinal Pigment Epithelium (RPE) without effecting neighboring layers as the photoreceptors or the choroid. SRT related RPE defects are ophthalmoscopically invisible. Owing to this invisibility and the variation of the threshold radiant exposure for RPE damage the treating physician does not know whether the treatment was successful or not. Thus measurement techniques enabling a correct dosing are a demanded element in SRT devices. The acquired signal can be used for monitoring or automatic irradiation control. Existing monitoring techniques are based on the detection of micro-bubbles. These bubbles are the origin of RPE cell damage for pulse durations in the ns and μs time regime 5μs. The detection can be performed by optical or acoustical approaches. Monitoring based on an acoustical approach has already been used to study the beneficial effects of SRT on diabetic macula edema and central serous retinopathy. We have developed a first real time feedback technique able to detect micro-bubble induced characteristics in the backscattered laser light fast enough to cease the laser irradiation within a burst. Therefore the laser energy within a burst of at most 30 pulses is increased linearly with every pulse. The laser irradiation is ceased as soon as micro-bubbles are detected. With this automatic approach it was possible to observe invisible lesions, an intact photoreceptor layer and a reconstruction of the RPE within one week.

  16. Instrumented Pneumatic-Impact Tester

    NASA Technical Reports Server (NTRS)

    Shelley, Richard M.; Armendariz, Norman

    1993-01-01

    Pneumatic-impact tester is small pressure chamber equipped with specimen holder and optical port. Device designed to test susceptibility of polymeric material to ignition by "pneumatic impact" in high-pressure gaseous oxygen. Used to determine differences among susceptibilities to ignition of different materials and of different batches of nominally same material proposed for use in systems containing pressurized oxygen. Also used to show characteristics of ignition and combustion.

  17. Instrumented Pneumatic-Impact Tester

    NASA Technical Reports Server (NTRS)

    Shelley, Richard M.; Armendariz, Norman

    1993-01-01

    Pneumatic-impact tester is small pressure chamber equipped with specimen holder and optical port. Device designed to test susceptibility of polymeric material to ignition by "pneumatic impact" in high-pressure gaseous oxygen. Used to determine differences among susceptibilities to ignition of different materials and of different batches of nominally same material proposed for use in systems containing pressurized oxygen. Also used to show characteristics of ignition and combustion.

  18. Experimental Plan for EDF Energy Creep Rabbit Graphite Irradiations- Rev. 2 (replaces Rev. 0 ORNL/TM/2013/49).

    SciTech Connect

    Burchell, Timothy D

    2014-07-01

    The experimental results obtained here will assist in the development and validation of future models of irradiation induced creep of graphite by providing the following data: Inert creep stain data from low to lifetime AGR fluence Inert creep-property data (especially CTE) from low to lifetime AGR fluence Effect of oxidation on creep modulus (by indirect comparison with experiment 1 and direct comparison with experiment 3 NB. Experiment 1 and 3 are not covered here) Data to develop a mechanistic understanding, including oAppropriate creep modulus (including pinning and high dose effects on structure) oInvestigation of CTE-creep strain behavior under inert conditions oInformation on the effect of applied stress/creep strain on crystallite orientation (requires XRD) oEffect of creep strain on micro-porosity (requires tomography & microscopy) This document describes the experimental work planned to meet the requirements of project technical specification [1] and EDF Energy requests for additional Pre-IE work. The PIE work is described in detail in this revision (Section 8 and 9).

  19. The characteristics of pneumatic piston drive

    NASA Astrophysics Data System (ADS)

    Bracha, Gabriel F.

    The article presents a study on the rodless pneumatic piston actuator. Mathematical model of the pneumatic actuator, static and dynamic characteristics are obtained and compared with the real drive characteristics.

  20. The characteristics of pneumatic piston drive

    NASA Astrophysics Data System (ADS)

    Bracha, Gabriel F.

    2016-11-01

    The article presents a study on the rodless pneumatic piston actuator. Mathematical model of the pneumatic actuator, static and dynamic characteristics are obtained and compared with the real drive characteristics.

  1. Pet rabbits.

    PubMed

    Hillyer, E V

    1994-01-01

    Pet rabbits are becoming more common, and rabbit owners are demanding quality veterinary care. This article provides a broad overview of pet rabbit medicine, which is a relatively new field compared to laboratory and farm rabbit medicine. The most common differential diagnoses for presenting complaints are summarized in table form. Disease conditions are reviewed individually in the text. Sources of further information on veterinary care of rabbits are listed throughout the text, in an appendix, and in the references.

  2. 49 CFR 236.590 - Pneumatic apparatus.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 4 2011-10-01 2011-10-01 false Pneumatic apparatus. 236.590 Section 236.590..., Train Control and Cab Signal Systems Inspection and Tests; Locomotive § 236.590 Pneumatic apparatus. Automatic train stop, train control, or cab signal pneumatic apparatus shall be inspected, cleaned, and...

  3. 49 CFR 236.590 - Pneumatic apparatus.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Pneumatic apparatus. 236.590 Section 236.590..., Train Control and Cab Signal Systems Inspection and Tests; Locomotive § 236.590 Pneumatic apparatus. Automatic train stop, train control, or cab signal pneumatic apparatus shall be inspected, cleaned, and...

  4. The characteristics of a pneumatic muscle

    NASA Astrophysics Data System (ADS)

    Pietrala, Dawid

    The article presents static and dynamic characteristics of pneumatic muscles. It presents the structure of the laboratory stand used to test pneumatic muscles. It discusses the methodology for determination of static and dynamic characteristics. The paper also illustrates characteristics showing the relationship of pneumatic muscles length and operating pressure, at a constant loading force (isotonic characteristics). It presents characteristics showing the relationship of pneumatic muscles shortening and values of loading forces, at a constant operational pressure (isobaric characteristics). It also shows the dependence of force generated by the muscle on the operating pressure, at a constant value of pneumatic muscles shortening (isometric characteristics). The paper also presents dynamic characteristics of a pneumatic muscle showing the response of an object to a gradual change in the operating pressure, at a constant loading force acting on the pneumatic muscle.

  5. Pneumatic Spoiler Controls Airfoil Lift

    NASA Technical Reports Server (NTRS)

    Hunter, D.; Krauss, T.

    1991-01-01

    Air ejection from leading edge of airfoil used for controlled decrease of lift. Pneumatic-spoiler principle developed for equalizing lift on helicopter rotor blades. Also used to enhance aerodynamic control of short-fuselage or rudderless aircraft such as "flying-wing" airplanes. Leading-edge injection increases maneuverability of such high-performance fixed-wing aircraft as fighters.

  6. Pneumatic Spoiler Controls Airfoil Lift

    NASA Technical Reports Server (NTRS)

    Hunter, D.; Krauss, T.

    1991-01-01

    Air ejection from leading edge of airfoil used for controlled decrease of lift. Pneumatic-spoiler principle developed for equalizing lift on helicopter rotor blades. Also used to enhance aerodynamic control of short-fuselage or rudderless aircraft such as "flying-wing" airplanes. Leading-edge injection increases maneuverability of such high-performance fixed-wing aircraft as fighters.

  7. Pneumatic gap sensor and method

    DOEpatents

    Bagdal, K.T.; King, E.L.; Follstaedt, D.W.

    1992-03-03

    An apparatus and method for monitoring and maintaining a predetermined width in the gap between a casting nozzle and a casting wheel, wherein the gap is monitored by means of at least one pneumatic gap sensor. The pneumatic gap sensor is mounted on the casting nozzle in proximity to the casting surface and is connected by means of a tube to a regulator and a transducer. The regulator provides a flow of gas through a restictor to the pneumatic gap sensor, and the transducer translates the changes in the gas pressure caused by the proximity of the casting wheel to the pneumatic gap sensor outlet into a signal intelligible to a control device. The relative positions of the casting nozzle and casting wheel can thereby be selectively adjusted to continually maintain a predetermined distance between their adjacent surfaces. The apparatus and method enables accurate monitoring of the actual casting gap in a simple and reliable manner resistant to the extreme temperatures and otherwise hostile casting environment. 6 figs.

  8. Pneumatic gap sensor and method

    DOEpatents

    Bagdal, Karl T.; King, Edward L.; Follstaedt, Donald W.

    1992-01-01

    An apparatus and method for monitoring and maintaining a predetermined width in the gap between a casting nozzle and a casting wheel, wherein the gap is monitored by means of at least one pneumatic gap sensor. The pneumatic gap sensor is mounted on the casting nozzle in proximity to the casting surface and is connected by means of a tube to a regulator and a transducer. The regulator provides a flow of gas through a restictor to the pneumatic gap sensor, and the transducer translates the changes in the gas pressure caused by the proximity of the casting wheel to the pneumatic gap sensor outlet into a signal intelligible to a control device. The relative positions of the casting nozzle and casting wheel can thereby be selectively adjusted to continually maintain a predetermined distance between their adjacent surfaces. The apparatus and method enables accurate monitoring of the actual casting gap in a simple and reliable manner resistant to the extreme temperatures and otherwise hostile casting environment.

  9. Rabbit medicine.

    PubMed

    Jordan, Dinah G

    2007-01-01

    When filling prescriptions for a rabbit, it is important to know whether the rabbit is a pet or is being raised as a source of food for human consumption. Several drugs widely used for pet rabbits are prohibited from exralabel use in animals raised for food production. The list of banned drugs should always be perused prior to filling a prescription for a rabbit being raised for food production. Since no veterinary-approved products exist for rabbits and most medications must be compounded, pharmacists are likely to encounter prescriptions for rabbits in their practice. A basic understanding of rabbit anatomy, physiolgy and common diseases will assist pharmacists in distinguishing between safe and dangerous drugs for administration to rabbits.

  10. Sliding pressure control valve for pneumatic hammer drill

    SciTech Connect

    Polsky, Yarom

    2011-08-30

    A pneumatic device control apparatus and method comprising a ported valve slidably fitted over a feed tube of the pneumatic device, and using a compliant biasing device to constrain motion of the valve to provide asymmetric timing for extended pressurization of a power chamber and reduced pressurization of a return chamber of the pneumatic device. The pneumatic device can be a pneumatic hammer drill.

  11. Model for pneumatic pellet injection

    SciTech Connect

    Hogan, J.T.; Milora, S.L.; Schuresko, D.D.

    1983-07-01

    A hydrodynamic code has been developed to model the performance of pneumatic pellet injection systems. The code describes one dimensional, unsteady compressible gas dynamics, including gas friction and heat transfer to the walls in a system with variable area. The mass, momentum, and energy equations are solved with an iterated Lax-Wendroff scheme with additional numerical viscosity. The code is described and comparisons with experimental data are presented.

  12. Note: A fast pneumatic sample-shuttle with attenuated shocks

    SciTech Connect

    Biancalana, Valerio; Dancheva, Yordanka; Stiaccini, Leonardo

    2014-03-15

    We describe a home-built pneumatic shuttle suitable for the fast displacement of samples in the vicinity of a highly sensitive atomic magnetometer. The samples are magnetized at 1 T using a Halbach assembly of magnets. The device enables the remote detection of free-induction-decay in ultra-low-field and zero-field nuclear magnetic resonance (NMR) experiments, in relaxometric measurements and in other applications involving the displacement of magnetized samples within time intervals as short as a few tens of milliseconds. Other possible applications of fast sample shuttling exist in radiological studies, where samples have to be irradiated and then analyzed in a cold environment.

  13. Electric versus hydraulics versus pneumatics

    SciTech Connect

    Not Available

    1985-01-01

    This book presents a collection of papers from a conference which considered the advantages and disadvantages of electric, hydraulic and pneumatic drives and actuators. The volume follows on the success of the 1983 conference on electric and hydraulic drives. Topics considered include fork lift trucks - an ideal application for regenerative transmissions; a hybrid-electric power system with hydrostatic transmission; electrics and hydraulics on roadheader machinery; hydraulic, electrical, pneumatic control - which way to go. an electrically-powered servo to drive the two axes of a missile launching platform - pros and cons when compared with the traditional hydraulic solution; the encapsulation of a novel intrinsically safe displacement transducer; mobile cryogenic pumping systems; automation of a wood-turning machine, hydraulic or electric. The choice of a servo motor for a specific application; developments in the design and control of pneumatic linear actuators; compressed air purification for instrumentation in the high technology industries; trends in prime mover choice for powered hand tools; and choosing the drive system for the right application.

  14. 21 CFR 878.5910 - Pneumatic tourniquet.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ...) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Therapeutic Devices § 878.5910 Pneumatic tourniquet... patient's limb and inflated to reduce or totally occlude circulation during surgery. (b)...

  15. 21 CFR 878.5910 - Pneumatic tourniquet.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ...) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Therapeutic Devices § 878.5910 Pneumatic tourniquet... patient's limb and inflated to reduce or totally occlude circulation during surgery. (b)...

  16. 21 CFR 878.5910 - Pneumatic tourniquet.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ...) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Therapeutic Devices § 878.5910 Pneumatic tourniquet... patient's limb and inflated to reduce or totally occlude circulation during surgery. (b)...

  17. 21 CFR 878.5910 - Pneumatic tourniquet.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ...) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Therapeutic Devices § 878.5910 Pneumatic tourniquet... patient's limb and inflated to reduce or totally occlude circulation during surgery. (b)...

  18. 21 CFR 878.5910 - Pneumatic tourniquet.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ...) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Therapeutic Devices § 878.5910 Pneumatic tourniquet... patient's limb and inflated to reduce or totally occlude circulation during surgery. (b)...

  19. [Modern pneumatic weapons and injuries they cause].

    PubMed

    Kozachenko, I N

    2013-01-01

    The data on the history of development and further improvement of pneumatic weapons are presented with special reference to specific features of different types and varieties of these weapons, cartridges for them, and the sphere of their application. Investigations into peculiarities of damages caused by high-capacity pneumatic weapons to the objects of forensic medical expertise affected from different distances are reviewed. Results of forensic medical expertise and clinical studies on the structure of body injuries inflicted by gunshots from pneumatic weapons to the human body are discussed. The author emphasizes the necessity of developing up-to-date terminology and classification of gunshot injuries caused by shooting from pneumatic weapons.

  20. Pneumatic conveying of pulverized solvent refined coal

    DOEpatents

    Lennon, Dennis R.

    1984-11-06

    A method for pneumatically conveying solvent refined coal to a burner under conditions of dilute phase pneumatic flow so as to prevent saltation of the solvent refined coal in the transport line by maintaining the transport fluid velocity above approximately 95 ft/sec.

  1. Pneumatic power is transmitted through air bearing

    NASA Technical Reports Server (NTRS)

    Johnson, H. I.; Wobig, O. A.

    1964-01-01

    A more efficient method for supplying high pressure air to an air bearing and pneumatic equipment mounted on it has been developed. The system uses a conventional air bearing and an air-supported sphere with a central passage. High pressure air is channeled through it into the pneumatic equipment on the sphere.

  2. Pneumatic pumping test for soil vacuum extraction

    SciTech Connect

    Cho, J.S.; DiGiulio, D.C.

    1992-08-01

    In-situ pneumatic pumping tests were performed to estimate the pneumatic permeability at a site containing soils contaminated with aviation gasoline. Determination of pneumatic permeability was necessary to evaluate soil-air discharge or pore volume exchange rates. Pressure propagation was measured in clustered vapor probes during the application of vacuum and positive pressure. An analytical solution for soil-air pressure distribution with a non-linear data fitting algorithm was adopted to obtain the pneumatic permeability from soil-air pressure distribution. Pneumatic pumping tests indicated substantially higher air discharge rates in the immediate vicinity of wells. The air discharge rate dissipated rapidly as distance from the wells increased. Application of increased vacuum or injection pressure resulted in substantially increased air flow in the immediate vicinity with small changes at a distance. This fact indicates that effective design should be based on air flow fields near wells, and the site specific design criteria should be determined with carefully conducted tests.

  3. A Study of Gas Economizing Pneumatic Cylinder

    NASA Astrophysics Data System (ADS)

    Li, T. C.; Wu, H. W.; Kuo, M. J.

    2006-10-01

    The pneumatic cylinder is the most typical actuator in the pneumatic equipment, and its mechanism is so simple that it is often used to operate point to point driving without the feedback loop in various automatic machines. But, the energy efficiency of pneumatic system is very poor compared with electrical systems and hydraulic systems. So, it is very important to discuss the energy saving for the pneumatic cylinder systems. In this thesis, we proposed three methods to apply the reduction in the air consumed for pneumatic cylinder systems. An air charge accumulator is used to absorb the exhausted compress air and a boost valve boosted the air to the higher pressure for used again. From the experiments, the direct used cylinder exhaust air may save about 40% of compress air.

  4. RANGE INCREASER FOR PNEUMATIC GAUGES

    DOEpatents

    Fowler, A.H.; Seaborn, G.B. Jr.

    1960-09-27

    An improved pneumatic gage is offered in which the linear range has been increased without excessive air consumption. This has been accomplished by providing an expansible antechamber connected to the nozzle of the gage so that the position of the nozzle with respect to the workpiece is varied automatically by variation in pressure within the antechamber. This arrangement ensures that the nozzle-to-workpiece clearance is maintained within certain limits, thus obtaining a linear relation of air flow to nozzle-to-workpiece clearance over a wider range.

  5. An animal model for the study of neuromuscular injury induced beneath and distal to a pneumatic tourniquet.

    PubMed

    Pedowitz, R A; Rydevik, B L; Gershuni, D H; Hargens, A R

    1990-11-01

    A well-controlled animal model is presented for the study of neuromuscular injury induced by a pneumatic tourniquet. This model comprises a curved tourniquet surrounded by a stiff exterior shell, both of which were specifically designed to fit the conical and oblong shape of the rabbit hindlimb. Computed tomographic imaging was used to assess transverse tissue displacement induced by tourniquet compression. The curved tourniquet/shell configuration occluded the distal arterial blood flow to the extremity at a significantly lower cuff inflation pressure than a straight tourniquet of equal width. The magnitude and distribution of tissue pressures in the subcutaneous and deep tissues beneath the tourniquet were similar to those recorded in previous human cadaver studies of tourniquet compression. This animal model will facilitate the quantitation and analysis of tissue injury induced beneath and distal to a pneumatic tourniquet. Such data can help define the critical pressure and time limits for the safe use of pneumatic tourniquets in extremity surgery.

  6. Caudal pneumaticity and pneumatic hiatuses in the sauropod dinosaurs Giraffatitan and Apatosaurus.

    PubMed

    Wedel, Mathew J; Taylor, Michael P

    2013-01-01

    Skeletal pneumaticity is found in the presacral vertebrae of most sauropod dinosaurs, but pneumaticity is much less common in the vertebrae of the tail. We describe previously unrecognized pneumatic fossae in the mid-caudal vertebrae of specimens of Giraffatitan and Apatosaurus. In both taxa, the most distal pneumatic vertebrae are separated from other pneumatic vertebrae by sequences of three to seven apneumatic vertebrae. Caudal pneumaticity is not prominent in most individuals of either of these taxa, and its unpredictable development means that it may be more widespread than previously recognised within Sauropoda and elsewhere in Saurischia. The erratic patterns of caudal pneumatization in Giraffatitan and Apatosaurus, including the pneumatic hiatuses, show that pneumatic diverticula were more broadly distributed in the bodies of the living animals than are their traces in the skeleton. Together with recently published evidence of cryptic diverticula--those that leave few or no skeletal traces--in basal sauropodomorphs and in pterosaurs, this is further evidence that pneumatic diverticula were widespread in ornithodirans, both across phylogeny and throughout anatomy.

  7. Caudal Pneumaticity and Pneumatic Hiatuses in the Sauropod Dinosaurs Giraffatitan and Apatosaurus

    PubMed Central

    Wedel, Mathew J.; Taylor, Michael P.

    2013-01-01

    Skeletal pneumaticity is found in the presacral vertebrae of most sauropod dinosaurs, but pneumaticity is much less common in the vertebrae of the tail. We describe previously unrecognized pneumatic fossae in the mid-caudal vertebrae of specimens of Giraffatitan and Apatosaurus. In both taxa, the most distal pneumatic vertebrae are separated from other pneumatic vertebrae by sequences of three to seven apneumatic vertebrae. Caudal pneumaticity is not prominent in most individuals of either of these taxa, and its unpredictable development means that it may be more widespread than previously recognised within Sauropoda and elsewhere in Saurischia. The erratic patterns of caudal pneumatization in Giraffatitan and Apatosaurus, including the pneumatic hiatuses, show that pneumatic diverticula were more broadly distributed in the bodies of the living animals than are their traces in the skeleton. Together with recently published evidence of cryptic diverticula—those that leave few or no skeletal traces—in basal sauropodomorphs and in pterosaurs, this is further evidence that pneumatic diverticula were widespread in ornithodirans, both across phylogeny and throughout anatomy. PMID:24205162

  8. Pneumatic retinopexy: principles and practice.

    PubMed

    Hilton, G F; Das, T; Majji, A B; Jalali, S

    1996-09-01

    Pneumatic retinopexy (PR) is an alternative to scleral buckling for the surgical repair of selected retinal detachments. A gas bubble is injected into the vitreous cavity, and the patient is positioned so that the bubble closes the retinal break (s), allowing absorption of the subretinal fluid. Cryotherapy or laser photocoagulation is applied around the retinal break(s) to form a permanent seal. The procedure can be done in an outpatient setting, and no incisions are required. A multicenter randomized controlled clinical trial has demonstrated that the anatomic success rate is comparable to scleral buckling, but the morbidity is significantly less with PR. If the macula was detached for less than two weeks, the visual results are significantly better with PR than with scleral buckling. Cataract surgery was required significantly more often following scleral buckling than following PR. Two independent reports have shown that an attempt with PR does not disadvantage the eye; such that the results of scleral buckling after failed PR are not significantly different than primary scleral buckling. A comprehensive review of the world literature on PR revealed 27 statistical series totaling 1,274 eyes. These combined series had a single-operation success rate of 80%, and 98% were cured with reoperations. Pneumatic retinopexy should be considered in cases without inferior or extensive retinal breaks and without significant proliferative vitreoretinopathy. The cost of buckling varies from 4 to 10 times that of PR.

  9. Pneumatic Variable Series Elastic Actuator

    PubMed Central

    Zheng, Hao; Wu, Molei; Shen, Xiangrong

    2016-01-01

    Inspired by human motor control theory, stiffness control is highly effective in manipulation and human-interactive tasks. The implementation of stiffness control in robotic systems, however, has largely been limited to closed-loop control, and suffers from multiple issues such as limited frequency range, potential instability, and lack of contribution to energy efficiency. Variable-stiffness actuator represents a better solution, but the current designs are complex, heavy, and bulky. The approach in this paper seeks to address these issues by using pneumatic actuator as a variable series elastic actuator (VSEA), leveraging the compressibility of the working fluid. In this work, a pneumatic actuator is modeled as an elastic element with controllable stiffness and equilibrium point, both of which are functions of air masses in the two chambers. As such, for the implementation of stiffness control in a robotic system, the desired stiffness/equilibrium point can be converted to the desired chamber air masses, and a predictive pressure control approach is developed to control the timing of valve switching to obtain the desired air mass while minimizing control action. Experimental results showed that the new approach in this paper requires less expensive hardware (on–off valve instead of proportional valve), causes less control action in implementation, and provides good control performance by leveraging the inherent dynamics of the actuator. PMID:27354755

  10. Pneumatic Variable Series Elastic Actuator.

    PubMed

    Zheng, Hao; Wu, Molei; Shen, Xiangrong

    2016-08-01

    Inspired by human motor control theory, stiffness control is highly effective in manipulation and human-interactive tasks. The implementation of stiffness control in robotic systems, however, has largely been limited to closed-loop control, and suffers from multiple issues such as limited frequency range, potential instability, and lack of contribution to energy efficiency. Variable-stiffness actuator represents a better solution, but the current designs are complex, heavy, and bulky. The approach in this paper seeks to address these issues by using pneumatic actuator as a variable series elastic actuator (VSEA), leveraging the compressibility of the working fluid. In this work, a pneumatic actuator is modeled as an elastic element with controllable stiffness and equilibrium point, both of which are functions of air masses in the two chambers. As such, for the implementation of stiffness control in a robotic system, the desired stiffness/equilibrium point can be converted to the desired chamber air masses, and a predictive pressure control approach is developed to control the timing of valve switching to obtain the desired air mass while minimizing control action. Experimental results showed that the new approach in this paper requires less expensive hardware (on-off valve instead of proportional valve), causes less control action in implementation, and provides good control performance by leveraging the inherent dynamics of the actuator.

  11. Milestone M3FT-15OR0203112. Build redesigned HFIR rabbit capsules and make ready for insertion for irradiation in HFIR

    SciTech Connect

    Howard, Richard H; McDuffee, Joel Lee; Okuniewski, Maria A.

    2015-09-01

    This report details the fabrication and delivery of two Fuel Cycle Research and Development irradiation capsules (FCRP20 and FCRP03), with associated quality assurance documentation, to the High Flux Isotope Reactor. The capsules and documentation were delivered by September 30, 2015, thus meeting the deadline for milestone M3FT-15OR0203112. These irradiation experiments irradiate metal parallelepiped specimens that may consist of various compositions including uranium metal, steel, etc. This document contains a copy of the completed capsule fabrication request sheets, which detail all constituent components, pertinent drawings, etc., along with a detailed summary of the capsule assembly process performed by the Thermal Hydraulics and Irradiation Engineering Group (THIEG) in the Reactor and Nuclear Systems Division. A complete fabrication package record is maintained by THIEG and is available upon request.

  12. Successful MPPF Pneumatics Verification and Validation Testing

    NASA Image and Video Library

    2017-03-28

    Engineers and technicians completed verification and validation testing of several pneumatic systems inside and outside the Multi-Payload Processing Facility (MPPF) at NASA's Kennedy Space Center in Florida. In view is the service platform for Orion spacecraft processing. To the left are several pneumatic panels. The MPPF will be used for offline processing and fueling of the Orion spacecraft and service module stack before launch. Orion also will be de-serviced in the MPPF after a mission. The Ground Systems Development and Operations Program (GSDO) is overseeing upgrades to the facility. The Engineering Directorate led the recent pneumatic tests.

  13. Phenomena of Pneumatic Tire Hydroplaning

    NASA Technical Reports Server (NTRS)

    Dreher, R. C.; Horne, W. B.

    1963-01-01

    Recent research on pneumatic tire hydroplaning has been collected and summarized with the aim of describing what is presently known about the phenomena of tire hydroplaning. A physical description of tire hydroplaning is given along with formulae for estimating the ground speed at which it occurs. Eight manifestations of tire hydroplaning which have been experimentally observed are presented and discussed. These manifestations are: detachment of tire footprint, hydrodynamic ground pressure, spin-down of wheel, suppression of tire bow wave, scouring action of escaping fluid in tire-ground footprint region, peaking of fluid displacement drag, loss in braking traction, and loss of tire directional stability. The vehicle, pavement, tire, and fluid parameters of importance to tire hydroplaning are listed and described. Finally, the hazards of tire hydroplaning to ground and air-vehicle-ground performance are listed, and procedures are given to minimize these effects.

  14. Pneumatic tools for vitreoretinal surgery.

    PubMed

    Romano, Mario R; Vallejo-Garcia, Jose Luis; Randazzo, Alessandro; Vinciguerra, Paolo

    2012-01-01

    One of the difficulties of microsurgery is learning how to control physiological tremors. The pneumatic tool eliminates the physiological tremor, but no tactile feedback is provided. The manual tremor when closing the forceps is completely eliminated and the exact target can be more easily grabbed. Forceps closure pressure can rise up to 50 psi, whereas the scissors can be used in two modes: multicut and proportional. When performing bimanual surgery the pedal range is divided into two steps: in the first step, the forceps are controlled, and in the second step, the forceps remain closed. At the same time the scissors start to work in the preselected mode. No adverse events occurred and no iatrogenic retinal breaks were produced. Precision and control sensation were a grateful surprise.

  15. Pneumatic displacement of submacular haemorrhage.

    PubMed

    Abdelkader, Ehab; Yip, Kay P; Cornish, Kurt Spiteri

    2016-01-01

    To evaluate the outcomes of pneumatic displacement of submacular hemorrhage secondary to choroidal neovascular membrane (CNV) (n = 9) and retinal arterial macroaneurysm (RAM) (n = 3). This is a retrospective case series study of 12 eyes from 12 patients in Aberdeen Royal Infirmary, Aberdeen, UK. The mean duration of visual loss was 10.8 ± 4.11 days. All cases received intravitreal injection of expansile gas within 24 h of presentation (C3F8 in 11 cases and SF6 in one case) and postured face down for five days. Anterior chamber paracentesis was done right after gas injection. Intravitreal anti-VEGF was injected at the same time in cases with CNV. Further anti-VEGF injections were done in CNV cases as needed afterwards. Cases were followed up for 6 months. The submacular hemorrhage was successfully displaced from underneath the fovea in all but one case. The bleeding disappeared totally in 44% of cases and was inferiorly displaced in 56%. VA improvement at 6 months was statistically significantly higher than baseline VA. All cases but 2 (one because of subfoveal fibrosis and one because of late presentation) experienced improved VA. The mean VA improved from 1.37 ± 0.18 logMAR at baseline to 0.83 ± 0.26 logMAR at 6 months. No complication related to the procedure was reported. Pneumatic displacement of submacular hemorrhage appears to be a safe and effective technique to treat the condition. It is an easy procedure that can be done in outpatient setting. Further studies are needed to validate our results.

  16. F-15 Pneumatic Forbody Controls

    NASA Technical Reports Server (NTRS)

    1994-01-01

    A series of test have been conducted in the Langley 30-by-60 Foot Tunnel to determine the effectiveness of several forebody control devices on a 10-percent-scale model of the F-15E. These test are part of a cooperative research program with the U.S. Air Force Wright Laboratory and the McDonnell Aircraft Company to determine the suitability of applying forebody controls to the F-15E aircraft. The forebody controls under investigation included mechanical concepts, such as deflectable strakes and rotating-randome devices, and pneumatic concepts, such as slotted-nozzle blowing. All these concepts are designed to provide increased maneuverability by enhancing yaw control at high angles of attack where conventional rudders become ineffective. Results from the tests show that the F-15E is well suited for the application of forebody-controls technology. After conducting a number of parametric variations, several mechanical and pneumatic forebody control options were identified that were capable of providing high levels of yaw control while minimizing the impact on other aircraft systems. Other desirable characteristics exhibited by these concepts were that the control effectiveness was retained over wide ranges of sideslip and that the level of yawing moment was easily controlled by varying either the mechanical deflection or the blowing rate. Subsequent piloted simulation studies conducted by the McDonnell Aircraft Company have shown that these improved levels of yaw control would significantly enhance the maneuverability of the aircraft. The promising results that were obtained during these tests have spawned interest in a flight-test program and possible future application to the F-15E aircraft.

  17. A pneumatic transfer system for special form {sup 252}Cf

    SciTech Connect

    Gehrke, R.J.; Berry, S.M.; Grafwallner, E.G.; Hoggan, J.M.

    1996-09-01

    A pneumatic transfer system has been developed for use with series 100 Special Form {sup 252}Cf. It was developed to reduce the exposure to personnel handling sources of {sup 252}Cf with masses up to 150 {micro}g by permitting remotely activated two-way transfer between the storage container and the irradiation position. The pneumatic transfer system also permits transfers for reproducible repetitive irradiation periods. In addition to the storage container equipped with quick-release fittings, the transfer system consists of an irradiation station, a control box with momentary contact switches to activate the air-pressure control valves and indicators to identify the location of the source, and connecting air hose and electrical wire. A source of 20 psig air and 110 volt electrical power are required for operation of the transfer system which can be easily moved and set up by one individual in 5 to 10 minutes. Tests have shown that rarely does a source become lodged in the transfer tubing, but two methods have been developed to handle incomplete transfers of the {sup 252}Cf source. The first method consists of closing one air vent to allow a pressure impulse to propel the source to the opposite side. The second method applies to those {sup 252}Cf capsules with a threaded or tapped end to which a small ferromagnetic piece can be attached; an incompletely transferred source in the transfer tube can then be guided to a position of safety by surrounding the transfer tubing containing the capsule with a horseshoe magnet attached to the end of a long pole.

  18. Pneumatic robotic systems for upper limb rehabilitation.

    PubMed

    Morales, Ricardo; Badesa, Francisco Javier; García-Aracil, Nicolás; Sabater, José María; Pérez-Vidal, Carlos

    2011-10-01

    The aim of rehabilitation robotic area is to research on the application of robotic devices to therapeutic procedures. The goal is to achieve the best possible motor, cognitive and functional recovery for people with impairments following various diseases. Pneumatic actuators are attractive for robotic rehabilitation applications because they are lightweight, powerful, and compliant, but their control has historically been difficult, limiting their use. This article first reviews the current state-of-art in rehabilitation robotic devices with pneumatic actuation systems reporting main features and control issues of each therapeutic device. Then, a new pneumatic rehabilitation robot for proprioceptive neuromuscular facilitation therapies and for relearning daily living skills: like taking a glass, drinking, and placing object on shelves is described as a case study and compared with the current pneumatic rehabilitation devices.

  19. Promising pneumatic punchers for borehole drilling

    SciTech Connect

    A.A. Lipin

    2005-03-15

    The state of borehole drilling by downhole pneumatic punchers and their potential use in open and underground mining as well as in exploration for reliable sampling are analyzed. Performance specification is presented for the new-generation pneumatic punchers equipped with a pin tool, effectively operating at a compressed-air pressure of 0.5-0.7 MPa, and with an additional extended exhaust from the power stroke chamber during working cycle.

  20. Bone and joint changes in pneumatic drillers.

    PubMed Central

    Burke, M J; Fear, E C; Wright, V

    1977-01-01

    A clinical and radiological survey of 34 men who were pneumatic drillers employed by the North East Gas Board, was carried out to determine the prevalence of osteoarthrosis. Mild osteoarthrosis of the elbows was found in 2 subjects only. Two drillers had radiological evidence of generalized osteoarthrosis elsewhere, and minor degenerative changes were present in the hands of 15 cases. Our findings do not support the view that pneumatic drillers are particularly prone to develop osteoarthrosis. Images PMID:879868

  1. Pneumatic fracturing of low permeability media

    SciTech Connect

    Schuring, J.R.

    1996-08-01

    Pneumatic fracturing of soils to enhance the removal and treatment of dense nonaqueous phase liquids is described. The process involves gas injection at a pressure exceeding the natural stresses and at a flow rate exceeding the permeability of the formation. The paper outlines geologic considerations, advantages and disadvantages, general technology considerations, low permeability media considerations, commercial availability, efficiency, and costs. Five case histories of remediation using pneumatic fracturing are briefly summarized. 11 refs., 2 figs., 1 tab.

  2. Pneumatic wrench retains or discharges nuts or bolts as desired

    NASA Technical Reports Server (NTRS)

    Bouille, J. R.

    1966-01-01

    Pneumatic wrench grips, screws or unscrews, and discharges a nut or bolt as desired. The device consists of a standard pneumatic wrench modified with a special hex bolt head socket assembly and a diaphragm air cylinder.

  3. Histophysiology of cellular immunity reactions in B-cell deprived rabbits. An X-irradiation model for delineation of an 'isolated T-cell system'.

    PubMed

    Veldman, J E; Keuning, F J

    1978-10-16

    Three times sublethal total body X-irradiation with thymus shielding--at 2 weeks' intervals--delineated a temporarily B-cell deprived animal model, only reconstituted with recently thymus-derived cells. The thymusdependent areas of peripheral lymphoid tissue-repleted with T-cells--are described. The cellular immune capacity of these animals with an "isolated T-cell system" was analyzed by means of skin allografting. Histological and autoradiographic studies were performed in draining lymph nodes after a variety of antigenic stimuli: skin allografts, S. java vaccin, horse-gamma-globulin, horse spleen ferritin and a contact sensitizer (Oxazolone).

  4. Evaluation of posterior clinoid process pneumatization by multidetector computed tomography.

    PubMed

    Burulday, Veysel; Akgül, Mehmet Hüseyin; Muluk, Nuray Bayar; Ozveren, Mehmet Faik; Kaya, Ahmet

    2016-10-21

    In the present study, we investigated the types and ratio of posterior clinoid process (PCP) pneumatization in paranasal sinus multidetector computed tomography (MDCT). Paranasal MDCT images of 541 subjects (227 males, 314 females), between 15 and 65 years old, were included into the study. Pneumatization of anterior clinoid process and pneumatization types (I, II, or III) were evaluated in the males and females. PCP pneumatization was detected in 20.7 % of the males and 11.5 % of the females. Right, left, and bilateral PCP pneumatizations were detected in 7.9, 5.7, and 7.0 % of the males and 2.9, 3.2, and 4.5 % of the females, respectively. PCP pneumatization of the males is significantly higher than the females. The most detected type of pneumatization was type I (61.2 %) for all groups. In right, left, and bilateral pneumatizations separately, type I pneumatization was the most detected pneumatization type with the ratio of the 70.4, 65.2, and 50.0 %, respectively. In males, type I (61.7 %), and similarly in females, type I (60.6 %) pneumatization were detected more. Type II and type III pneumatizations were detected in decreasing order in both groups. In younger subjects, pneumatization of posterior clinoid process was found as higher, and in older subjects, PCP pneumatization was found as lower. Sclerosis process related to the aging may be responsible for the lower pneumatization ratios in older subjects. Structure of the surrounding regions of PCP is important for surgical procedures related to cavernous sinus, basilar apex aneurysms, and mass lesions. Preoperative radiological examinations are useful for operative planning. Any anomalies to PCP can cause unnecessary injury to the neurovascular complex structure around the cavernous sinus or postclinoidectomy CSF fistulas. Posterior clinoidectomies should be avoided in patients with type III PCP pneumatization to prevent CSF fistulas.

  5. PNEUMATIC PUMP TEST FOR DESIGN OF SOIL VACUUM EXTRACTION

    EPA Science Inventory

    In-situ pneumatic pumping tests were performed to estimate the pneumatic permeability at a site containing soils contaminated with aviation gasoline. Determination of pneumatic permeability was necessary to evaluate soil-air discharge or pore volume exchange rates. Pressure propa...

  6. 30 CFR 56.14114 - Air valves for pneumatic equipment.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Air valves for pneumatic equipment. 56.14114... Equipment Safety Devices and Maintenance Requirements § 56.14114 Air valves for pneumatic equipment. A manual master quick-close type air valve shall be installed on all pneumatic-powered equipment if there...

  7. 30 CFR 57.14114 - Air valves for pneumatic equipment.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Air valves for pneumatic equipment. 57.14114... and Equipment Safety Devices and Maintenance Requirements § 57.14114 Air valves for pneumatic equipment. A manual master quick-close type air valve shall be installed on all pneumatic-powered equipment...

  8. 14 CFR 23.1438 - Pressurization and pneumatic systems.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Pressurization and pneumatic systems. 23... Equipment Miscellaneous Equipment § 23.1438 Pressurization and pneumatic systems. (a) Pressurization system... normal operating pressure. (b) Pneumatic system elements must be burst pressure tested to 3.0 times, and...

  9. 14 CFR 25.1438 - Pressurization and pneumatic systems.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Pressurization and pneumatic systems. 25... § 25.1438 Pressurization and pneumatic systems. (a) Pressurization system elements must be burst.... (b) Pneumatic system elements must be burst pressure tested to 3.0 times, and proof pressure tested...

  10. 49 CFR 236.817 - Switch, electro-pneumatic.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Switch, electro-pneumatic. 236.817 Section 236.817 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION... Switch, electro-pneumatic. A switch operated by an electro-pneumatic switch-and-lock movement. ...

  11. 49 CFR 236.817 - Switch, electro-pneumatic.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 4 2011-10-01 2011-10-01 false Switch, electro-pneumatic. 236.817 Section 236.817 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION... Switch, electro-pneumatic. A switch operated by an electro-pneumatic switch-and-lock movement....

  12. PNEUMATIC PUMP TEST FOR DESIGN OF SOIL VACUUM EXTRACTION

    EPA Science Inventory

    In-situ pneumatic pumping tests were performed to estimate the pneumatic permeability at a site containing soils contaminated with aviation gasoline. Determination of pneumatic permeability was necessary to evaluate soil-air discharge or pore volume exchange rates. Pressure propa...

  13. 21 CFR 882.4370 - Pneumatic cranial drill motor.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Pneumatic cranial drill motor. 882.4370 Section... drill motor. (a) Identification. A pneumatic cranial drill motor is a pneumatically operated power source used with removable rotating surgical cutting tools or drill bits on a patient's skull. (b...

  14. 21 CFR 882.4370 - Pneumatic cranial drill motor.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Pneumatic cranial drill motor. 882.4370 Section... drill motor. (a) Identification. A pneumatic cranial drill motor is a pneumatically operated power source used with removable rotating surgical cutting tools or drill bits on a patient's skull. (b...

  15. 21 CFR 882.4370 - Pneumatic cranial drill motor.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Pneumatic cranial drill motor. 882.4370 Section... drill motor. (a) Identification. A pneumatic cranial drill motor is a pneumatically operated power source used with removable rotating surgical cutting tools or drill bits on a patient's skull. (b...

  16. 49 CFR 236.817 - Switch, electro-pneumatic.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 4 2013-10-01 2013-10-01 false Switch, electro-pneumatic. 236.817 Section 236.817 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION... Switch, electro-pneumatic. A switch operated by an electro-pneumatic switch-and-lock movement....

  17. 49 CFR 236.817 - Switch, electro-pneumatic.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 4 2014-10-01 2014-10-01 false Switch, electro-pneumatic. 236.817 Section 236.817 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION... Switch, electro-pneumatic. A switch operated by an electro-pneumatic switch-and-lock movement....

  18. 49 CFR 236.817 - Switch, electro-pneumatic.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 4 2012-10-01 2012-10-01 false Switch, electro-pneumatic. 236.817 Section 236.817 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION... Switch, electro-pneumatic. A switch operated by an electro-pneumatic switch-and-lock movement....

  19. 21 CFR 870.2780 - Hydraulic, pneumatic, or photoelectric plethysmographs.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Hydraulic, pneumatic, or photoelectric... § 870.2780 Hydraulic, pneumatic, or photoelectric plethysmographs. (a) Identification. A hydraulic... using hydraulic, pneumatic, or photoelectric measurement techniques. (b) Classification. Class...

  20. 21 CFR 870.2780 - Hydraulic, pneumatic, or photoelectric plethysmographs.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Hydraulic, pneumatic, or photoelectric... § 870.2780 Hydraulic, pneumatic, or photoelectric plethysmographs. (a) Identification. A hydraulic... using hydraulic, pneumatic, or photoelectric measurement techniques. (b) Classification. Class...

  1. 21 CFR 870.2780 - Hydraulic, pneumatic, or photoelectric plethysmographs.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Hydraulic, pneumatic, or photoelectric... § 870.2780 Hydraulic, pneumatic, or photoelectric plethysmographs. (a) Identification. A hydraulic... using hydraulic, pneumatic, or photoelectric measurement techniques. (b) Classification. Class...

  2. 21 CFR 870.2780 - Hydraulic, pneumatic, or photoelectric plethysmographs.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Hydraulic, pneumatic, or photoelectric... § 870.2780 Hydraulic, pneumatic, or photoelectric plethysmographs. (a) Identification. A hydraulic... using hydraulic, pneumatic, or photoelectric measurement techniques. (b) Classification. Class...

  3. 21 CFR 870.2780 - Hydraulic, pneumatic, or photoelectric plethysmographs.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Hydraulic, pneumatic, or photoelectric... § 870.2780 Hydraulic, pneumatic, or photoelectric plethysmographs. (a) Identification. A hydraulic... using hydraulic, pneumatic, or photoelectric measurement techniques. (b) Classification. Class...

  4. 21 CFR 882.4370 - Pneumatic cranial drill motor.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Pneumatic cranial drill motor. 882.4370 Section 882.4370 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... drill motor. (a) Identification. A pneumatic cranial drill motor is a pneumatically operated...

  5. 21 CFR 882.4370 - Pneumatic cranial drill motor.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Pneumatic cranial drill motor. 882.4370 Section... drill motor. (a) Identification. A pneumatic cranial drill motor is a pneumatically operated power source used with removable rotating surgical cutting tools or drill bits on a patient's skull....

  6. Back to Basics: Pneumatic Tourniquet Use.

    PubMed

    Spruce, Lisa

    2017-09-01

    Pneumatic tourniquets are commonly used in surgeries involving the limbs to achieve a nearly bloodless surgery and an optimal operating field or when administering regional anesthesia during surgery on a limb. Complications can arise from the use of tourniquets, including nerve injuries, pain, compartment syndrome, pressure injuries, chemical burns, and tissue necrosis. More serious injuries-including deep vein thrombosis, thermal damage to tissues, severe ischemic injuries, and rhabdomyolysis-also can occur. Therefore, it is important for perioperative team members to understand how to use pneumatic tourniquets effectively and safely to provide the best possible care to patients. This article addresses the safety risks to patients when using pneumatic tourniquets and optimal safe use of these devices. Copyright © 2017 AORN, Inc. Published by Elsevier Inc. All rights reserved.

  7. [Development of an adaptive pneumatic tourniquet].

    PubMed

    Liu, Hongyun; Zhang, Zhengbo; Li, Kaiyuan; Guo, Junyan; Wang, Weidong

    2012-06-01

    A new adaptive pneumatic tourniquet was developed for limb operation and first-aid. The crucial hardware circuits of the adaptive pneumatic tourniquet were designed based on the microprocessor C8051F340 and blood pressure module CSN602, software was programmed and an experiment was carried out for verifying the system. Results showed that the prototype could measure accurately systolic blood pressure, heart rate and other relative parameters and the designed device could adjust tourniquet cuff's pressure through inflation and deflation according to systolic blood pressure and limb circumference. This designed system integrated the advantages of the adaptive pneumatic tourniquet, and could be used for controlling life-threatening extremity hemorrhage operation and maintaining a bloodless opeation field.

  8. Pneumatic Rupture of Rectosigmoid; a Case Report.

    PubMed

    Montazeri, Mohammad; Farhangi, Bahman; Montazeri, Mahmood

    2014-01-01

    Pneumatic rectosigmoid rapture is usually occurred following the inappropriate fun by direct entering a high volume of the air through the pneumatic device to the anus. Such an event was reported for the first time in 1904 by Stone. Diagnosis and treatment of such injuries are often delayed because of some social limitations and preventing the patient form explaining the event. Colon sigmoid rupture and pneumoperitoneum is one of the most dangerous and life treating complications of entering a high volume of the air to the rectum in a short time. There are only a few reports regarding the similar cases. Here, a case of pneumatic rectosigmoid rapture was reported in a 53 year-old male following an inappropriate fun.

  9. Transurethral Pneumatic Cystolithotripsy: A Novel Approach.

    PubMed

    Ali, Ahmed Issam; Fathelbab, Tarek Khalaf; Abdelhamid, Amr Mohamed; Elbadry, Mohamed; Alshara, Luay; Anwar, Ahmed Zaki Mohamed; Galal, Ehab Mohmed; Tawfiek, Ehab Rifat

    2016-06-01

    Various endoscopic instruments used in treating renal stones have been used in managing bladder calculi. Our aim is to evaluate the use of transurethral ureteroscopic pneumatic cystolithotripsy for the management of large bladder calculi. In a retrospective study conducted between May 2005 and July 2011, 53 patients with solitary bladder stones were subjected to our technique, transurethral ureteroscopic pneumatic cystolithotripsy. The mean patient age was 54.3 years. The mean stone size was 4.8 cm. Diagnostic cystoscopy was performed first. A semirigid ureteroscope with a pneumatic probe was introduced through the cystoscope sheath, and pneumatic lithotripsy was performed. The cystoscope sheath works as a draining channel, allowing bladder evacuation. The bladder collapses over the stone and, subsequently, prevents stone migration, which shortens the lithotripsy's duration. Stone immobilization allows the transmission of full pneumatic power to the stone. The stone fragments were removed through periodic bladder irrigation using an Ellick evacuation-irrigation system, and a 16F Foley catheter was placed at the end of the procedure. Our technique was effective in all cases, including stone-free bladders. No surgical complications were detected. The mean operative time was 83 ± 21.0 minutes, which is comparable to that of standard management. The mean duration of lithotripsy and evacuation was 29.7 ± 18.4 minutes. In the postoperative period, patients were followed up for 18 months, with no urethral stricture being reported in any case. The transurethral ureteroscopic pneumatic cystolithotripsy procedure is a safe technique for the management of large bladder calculi. It allows the bladder to collapse over the stone, leading to stone immobilization and, subsequently, decreasing lithotripsy duration. Our procedure is associated with a minimal chance of postoperative urethral injury because all stone fragments are evacuated through the cystoscope sheath

  10. Guidelines help design pneumatic control systems

    SciTech Connect

    Curry, R.N.

    1981-01-26

    The three areas of particular interest to the gas-transmission engineer about pneumatic-instrument-operated control valves are (1) the fail-position probability of a system, (2) the designated action required for each component in the pneumatic circuit, and (3) the schematically defined position of each component. Compared with self-operated control valves, the instrument-operated systems perform many more functions; they can control the flow and the volume or flow-volume combinations, with both pressure override and underride, and will adapt conveniently to remote operation. Schematic diagrams illustrate the numerous system designs possible for pressure-regulation, flow-control, and relief-valve duties.

  11. Successful MPPF Pneumatics Verification and Validation Testing

    NASA Image and Video Library

    2017-03-28

    Engineers and technicians completed verification and validation testing of several pneumatic systems inside and outside the Multi-Payload Processing Facility (MPPF) at NASA's Kennedy Space Center in Florida. In view is the service platform for Orion spacecraft processing. The MPPF will be used for offline processing and fueling of the Orion spacecraft and service module stack before launch. Orion also will be de-serviced in the MPPF after a mission. The Ground Systems Development and Operations Program (GSDO) is overseeing upgrades to the facility. The Engineering Directorate led the recent pneumatic tests.

  12. Successful MPPF Pneumatics Verification and Validation Testing

    NASA Image and Video Library

    2017-03-28

    Engineers and technicians completed verification and validation testing of several pneumatic systems inside and outside the Multi-Payload Processing Facility (MPPF) at NASA's Kennedy Space Center in Florida. In view is the top level of the service platform for Orion spacecraft processing. The MPPF will be used for offline processing and fueling of the Orion spacecraft and service module stack before launch. Orion also will be de-serviced in the MPPF after a mission. The Ground Systems Development and Operations Program (GSDO) is overseeing upgrades to the facility. The Engineering Directorate led the recent pneumatic tests.

  13. Pneumatically switchable graded index metamaterial lens

    NASA Astrophysics Data System (ADS)

    Khodasevych, I. E.; Shadrivov, I. V.; Powell, D. A.; Rowe, W. S. T.; Mitchell, A.

    2013-01-01

    A low-profile pneumatically switchable graded index metamaterial lens operating at 9 GHz is proposed and practically demonstrated. An effective graded refractive index is engineered using an array of electric resonators of differing resonant frequency. Normal orientation of the resonators allows ultrathin single metamaterial layer lens design. Switching between focusing and non-focusing states is practically demonstrated by shorting the gaps in split ring resonators and eliminating the resonant response and the phase difference between the elements across the lens with pneumatically actuated metal patches that are pressed against the gaps of the resonators as the pressure in the chamber is reduced.

  14. Rabbit hematology.

    PubMed

    Marshall, Kemba L

    2008-09-01

    Using laboratory animal medicine as an established resource, companion animal veterinarians have access to many physiologic and basic science studies that we can now merge with our clinical impressions. By working with reference laboratories, companion animal veterinarians are poised to accelerate our knowledge of the normal rabbit rapidly. The aim of this article is to discuss normal hematopoiesis and infectious and metabolic diseases that specifically target the hemolymphatic system. Additionally, photographic representation of cell types is provided.

  15. Vertebral Pneumaticity in the Ornithomimosaur Archaeornithomimus (Dinosauria: Theropoda) Revealed by Computed Tomography Imaging and Reappraisal of Axial Pneumaticity in Ornithomimosauria

    PubMed Central

    Watanabe, Akinobu; Eugenia Leone Gold, Maria; Brusatte, Stephen L.; Benson, Roger B. J.; Choiniere, Jonah; Davidson, Amy; Norell, Mark A.

    2015-01-01

    Among extant vertebrates, pneumatization of postcranial bones is unique to birds, with few known exceptions in other groups. Through reduction in bone mass, this feature is thought to benefit flight capacity in modern birds, but its prevalence in non-avian dinosaurs of variable sizes has generated competing hypotheses on the initial adaptive significance of postcranial pneumaticity. To better understand the evolutionary history of postcranial pneumaticity, studies have surveyed its distribution among non-avian dinosaurs. Nevertheless, the degree of pneumaticity in the basal coelurosaurian group Ornithomimosauria remains poorly known, despite their potential to greatly enhance our understanding of the early evolution of pneumatic bones along the lineage leading to birds. Historically, the identification of postcranial pneumaticity in non-avian dinosaurs has been based on examination of external morphology, and few studies thus far have focused on the internal architecture of pneumatic structures inside the bones. Here, we describe the vertebral pneumaticity of the ornithomimosaur Archaeornithomimus with the aid of X-ray computed tomography (CT) imaging. Complementary examination of external and internal osteology reveals (1) highly pneumatized cervical vertebrae with an elaborate configuration of interconnected chambers within the neural arch and the centrum; (2) anterior dorsal vertebrae with pneumatic chambers inside the neural arch; (3) apneumatic sacral vertebrae; and (4) a subset of proximal caudal vertebrae with limited pneumatic invasion into the neural arch. Comparisons with other theropod dinosaurs suggest that ornithomimosaurs primitively exhibited a plesiomorphic theropod condition for axial pneumaticity that was extended among later taxa, such as Archaeornithomimus and large bodied Deinocheirus. This finding corroborates the notion that evolutionary increases in vertebral pneumaticity occurred in parallel among independent lineages of bird

  16. Vertebral Pneumaticity in the Ornithomimosaur Archaeornithomimus (Dinosauria: Theropoda) Revealed by Computed Tomography Imaging and Reappraisal of Axial Pneumaticity in Ornithomimosauria.

    PubMed

    Watanabe, Akinobu; Eugenia Leone Gold, Maria; Brusatte, Stephen L; Benson, Roger B J; Choiniere, Jonah; Davidson, Amy; Norell, Mark A

    2015-01-01

    Among extant vertebrates, pneumatization of postcranial bones is unique to birds, with few known exceptions in other groups. Through reduction in bone mass, this feature is thought to benefit flight capacity in modern birds, but its prevalence in non-avian dinosaurs of variable sizes has generated competing hypotheses on the initial adaptive significance of postcranial pneumaticity. To better understand the evolutionary history of postcranial pneumaticity, studies have surveyed its distribution among non-avian dinosaurs. Nevertheless, the degree of pneumaticity in the basal coelurosaurian group Ornithomimosauria remains poorly known, despite their potential to greatly enhance our understanding of the early evolution of pneumatic bones along the lineage leading to birds. Historically, the identification of postcranial pneumaticity in non-avian dinosaurs has been based on examination of external morphology, and few studies thus far have focused on the internal architecture of pneumatic structures inside the bones. Here, we describe the vertebral pneumaticity of the ornithomimosaur Archaeornithomimus with the aid of X-ray computed tomography (CT) imaging. Complementary examination of external and internal osteology reveals (1) highly pneumatized cervical vertebrae with an elaborate configuration of interconnected chambers within the neural arch and the centrum; (2) anterior dorsal vertebrae with pneumatic chambers inside the neural arch; (3) apneumatic sacral vertebrae; and (4) a subset of proximal caudal vertebrae with limited pneumatic invasion into the neural arch. Comparisons with other theropod dinosaurs suggest that ornithomimosaurs primitively exhibited a plesiomorphic theropod condition for axial pneumaticity that was extended among later taxa, such as Archaeornithomimus and large bodied Deinocheirus. This finding corroborates the notion that evolutionary increases in vertebral pneumaticity occurred in parallel among independent lineages of bird

  17. Microfluidic Pneumatic Logic Circuits and Digital Pneumatic Microprocessors for Integrated Microfluidic Systems

    PubMed Central

    Rhee, Minsoung

    2010-01-01

    We have developed pneumatic logic circuits and microprocessors built with microfluidic channels and valves in polydimethylsiloxane (PDMS). The pneumatic logic circuits perform various combinational and sequential logic calculations with binary pneumatic signals (atmosphere and vacuum), producing cascadable outputs based on Boolean operations. A complex microprocessor is constructed from combinations of various logic circuits and receives pneumatically encoded serial commands at a single input line. The device then decodes the temporal command sequence by spatial parallelization, computes necessary logic calculations between parallelized command bits, stores command information for signal transportation and maintenance, and finally executes the command for the target devices. Thus, such pneumatic microprocessors will function as a universal on-chip control platform to perform complex parallel operations for large-scale integrated microfluidic devices. To demonstrate the working principles, we have built 2-bit, 3-bit, 4-bit, and 8-bit microprecessors to control various target devices for applications such as four color dye mixing, and multiplexed channel fluidic control. By significantly reducing the need for external controllers, the digital pneumatic microprocessor can be used as a universal on-chip platform to autonomously manipulate microfluids in a high throughput manner. PMID:19823730

  18. Improving dynamic performances of PWM-driven servo-pneumatic systems via a novel pneumatic circuit.

    PubMed

    Taghizadeh, Mostafa; Ghaffari, Ali; Najafi, Farid

    2009-10-01

    In this paper, the effect of pneumatic circuit design on the input-output behavior of PWM-driven servo-pneumatic systems is investigated and their control performances are improved using linear controllers instead of complex and costly nonlinear ones. Generally, servo-pneumatic systems are well known for their nonlinear behavior. However, PWM-driven servo-pneumatic systems have the advantage of flexibility in the design of pneumatic circuits which affects the input-output linearity of the whole system. A simple pneumatic circuit with only one fast switching valve is designed which leads to a quasi-linear input-output relation. The quasi-linear behavior of the proposed circuit is verified both experimentally and by simulations. Closed loop position control experiments are then carried out using linear P- and PD-controllers. Since the output position is noisy and cannot be directly differentiated, a Kalman filter is designed to estimate the velocity of the cylinder. Highly improved tracking performances are obtained using these linear controllers, compared to previous works with nonlinear controllers.

  19. Microfluidic pneumatic logic circuits and digital pneumatic microprocessors for integrated microfluidic systems.

    PubMed

    Rhee, Minsoung; Burns, Mark A

    2009-11-07

    We have developed pneumatic logic circuits and microprocessors built with microfluidic channels and valves in polydimethylsiloxane (PDMS). The pneumatic logic circuits perform various combinational and sequential logic calculations with binary pneumatic signals (atmosphere and vacuum), producing cascadable outputs based on Boolean operations. A complex microprocessor is constructed from combinations of various logic circuits and receives pneumatically encoded serial commands at a single input line. The device then decodes the temporal command sequence by spatial parallelization, computes necessary logic calculations between parallelized command bits, stores command information for signal transportation and maintenance, and finally executes the command for the target devices. Thus, such pneumatic microprocessors will function as a universal on-chip control platform to perform complex parallel operations for large-scale integrated microfluidic devices. To demonstrate the working principles, we have built 2-bit, 3-bit, 4-bit, and 8-bit microprocessors to control various target devices for applications such as four color dye mixing, and multiplexed channel fluidic control. By significantly reducing the need for external controllers, the digital pneumatic microprocessor can be used as a universal on-chip platform to autonomously manipulate microfluids in a high throughput manner.

  20. Assessment of Pneumatic Controller Emission Measurements ...

    EPA Pesticide Factsheets

    Oil and Natural Gas (ONG) production facilities have the potential to emit greenhouse gases such as methane (CH4) and other hydrocarbons (HCs) to the atmosphere. ONG production sites have multiple emission sources including storage tank venting, enclosed combustion devices, engine exhaust, pneumatic controllers and uncontrolled leaks. Accounting for up to 37.8 percent of CH4 emissions, pneumatic controllers are one of the most significant sources of CH4 in ONG production field operations. Recent measurement studies used the only commercially-available high volume sampling (HVS) technology (Bacharach Hi Flow Sampler, Bacharach, Inc., New Kensington, PA) to quantify CH4 emission rates of pneumatic devices on ONG production pads and compare to inventory estimates. Other studies indicate that this HVS may malfunction, causing underestimates of emissions in certain scenarios encountered in ONG production and should not be used for some sources such as heavy emissions from condensate storage tanks. The HVS malfunction can occur on relatively large emissions, where the measured leak concentrations exceed 5%, and is ascribed to a sensor transition failure in the instrument. The HVS malfunction is believed to be exacerbated by several factors (large emission rates, amount of non-CH4 HCs in the emission stream, non-optimal HVS calibration frequency, firmware, and emission measurement coupling geometries). The degree to which HVS measurements of emissions from pneumatic co

  1. First Approach of Pneumatic Anthropomorphic Hand

    DTIC Science & Technology

    2001-10-25

    weight and minimum consumption, minimum control and natural appearance. Keywords- Anthropomorphic, hand, Pneumatic system, Prosthesis 1. INTRODUCTION...and controls that are compared with the tasks that Human hand can carry out. Each project determines the diverse possibilities of manipulation and...increases the possibilities of acceptance of prosthesis by the user. Multiple degrees of freedom of the prosthesis are difficult to control independently

  2. Distortion Of Pressure Signals In Pneumatic Tubes

    NASA Technical Reports Server (NTRS)

    Whitmore, Stephen A.; Gilyard, Glenn B.; Curry, Robert; Lindsey, William

    1993-01-01

    NASA technical memorandum describes experimental investigation of distorting effects of propagation of pressure signals along narrow pneumatic tubes from pressure-sensing orifices on surfaces of models or aircraft to pressure sensors distant from orifices. Pressure signals distorted principally by frictional damping along walls of tubes and by reflections at orifice and sensor ends.

  3. Evaluating a device for pneumatic lint cleaning

    USDA-ARS?s Scientific Manuscript database

    Research exploring innovative techniques to clean ginned lint while reducing short fiber and neps has led to evaluations of a pneumatic fractionator. This device is typically used to determine foreign matter content of seed cotton at the USDA cotton ginning research laboratories. No modifications we...

  4. Assessment of Pneumatic Controller Emission Measurements ...

    EPA Pesticide Factsheets

    Oil and Natural Gas (ONG) production facilities have the potential to emit greenhouse gases such as methane (CH4) and other hydrocarbons (HCs) to the atmosphere. ONG production sites have multiple emission sources including storage tank venting, enclosed combustion devices, engine exhaust, pneumatic controllers and uncontrolled leaks. Accounting for up to 37.8 percent of CH4 emissions, pneumatic controllers are one of the most significant sources of CH4 in ONG production field operations. Recent measurement studies used the only commercially-available high volume sampling (HVS) technology (Bacharach Hi Flow Sampler, Bacharach, Inc., New Kensington, PA) to quantify CH4 emission rates of pneumatic devices on ONG production pads and compare to inventory estimates. Other studies indicate that this HVS may malfunction, causing underestimates of emissions in certain scenarios encountered in ONG production and should not be used for some sources such as heavy emissions from condensate storage tanks. The HVS malfunction can occur on relatively large emissions, where the measured leak concentrations exceed 5%, and is ascribed to a sensor transition failure in the instrument. The HVS malfunction is believed to be exacerbated by several factors (large emission rates, amount of non-CH4 HCs in the emission stream, non-optimal HVS calibration frequency, firmware, and emission measurement coupling geometries). The degree to which HVS measurements of emissions from pneumatic co

  5. Analysis of fine coal pneumatic systems

    SciTech Connect

    Mathur, M.P.; Rohatgi, N.D.; Klinzing, G.E.

    1987-01-01

    Many fossil fuel energy processes depend on the movement of solids by pneumatic transport. Despite the considerable amount of work reported in the literature on pneumatic transport, the design of new industrial systems for new products continues to rely to a great extent on empiricism. A pilot-scale test facility has been constructed at Pittsburgh Energy Technology Center (PETC) and is equipped with modern sophisticated measuring techniques (such as Pressure Transducers, Auburn Monitors, Micro Motion Mass flowmeters) and an automatic computer-controlled data acquisition system to study the effects of particle pneumatic transport. Pittsburgh Seam and Montana rosebud coals of varying size consist and moisture content were tested in the atmospheric and pressurized coal flow test loops (AP/CFTL and HP/CFTL) at PETC. The system parameters included conveying gas velocity, injector tank pressure, screw conveyor speed, pipe radius, and pipe bends. In the following report, results from the coal flow tests were presented and analyzed. Existing theories and correlations on two-phase flows were reviewed. Experimental data were compared with values calculated from empirically or theoretically derived equations available in the literature, and new correlations were proposed, when applicable, to give a better interpretation of the data and a better understanding of the various flow regimes involved in pneumatic transport. 55 refs., 56 figs., 6 tabs.

  6. 49 CFR 236.590 - Pneumatic apparatus.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ..., DEPARTMENT OF TRANSPORTATION RULES, STANDARDS, AND INSTRUCTIONS GOVERNING THE INSTALLATION, INSPECTION, MAINTENANCE, AND REPAIR OF SIGNAL AND TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES Automatic Train Stop.... Automatic train stop, train control, or cab signal pneumatic apparatus shall be inspected, cleaned, and...

  7. 49 CFR 236.590 - Pneumatic apparatus.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ..., DEPARTMENT OF TRANSPORTATION RULES, STANDARDS, AND INSTRUCTIONS GOVERNING THE INSTALLATION, INSPECTION, MAINTENANCE, AND REPAIR OF SIGNAL AND TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES Automatic Train Stop.... Automatic train stop, train control, or cab signal pneumatic apparatus shall be inspected, cleaned, and...

  8. 49 CFR 236.590 - Pneumatic apparatus.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ..., DEPARTMENT OF TRANSPORTATION RULES, STANDARDS, AND INSTRUCTIONS GOVERNING THE INSTALLATION, INSPECTION, MAINTENANCE, AND REPAIR OF SIGNAL AND TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES Automatic Train Stop.... Automatic train stop, train control, or cab signal pneumatic apparatus shall be inspected, cleaned, and...

  9. Distortion Of Pressure Signals In Pneumatic Tubes

    NASA Technical Reports Server (NTRS)

    Whitmore, Stephen A.; Gilyard, Glenn B.; Curry, Robert; Lindsey, William

    1993-01-01

    NASA technical memorandum describes experimental investigation of distorting effects of propagation of pressure signals along narrow pneumatic tubes from pressure-sensing orifices on surfaces of models or aircraft to pressure sensors distant from orifices. Pressure signals distorted principally by frictional damping along walls of tubes and by reflections at orifice and sensor ends.

  10. Pneumatic boot for helicopter rotor deicing

    NASA Technical Reports Server (NTRS)

    Blaha, B. J.; Evanich, P. L.

    1981-01-01

    Pneumatic deicer boots for helicopter rotor blades were tested. The tests were conducted in the 6 by 9 ft icing research tunnel on a stationary section of a UH-IH helicopter main rotor blade. The boots were effective in removing ice and in reducing aerodynamic drag due to ice.

  11. Enhancing in situ bioremediation with pneumatic fracturing

    SciTech Connect

    Anderson, D.B.; Peyton, B.M.; Liskowitz, J.L.; Fitzgerald, C.; Schuring, J.R.

    1994-04-01

    A major technical obstacle affecting the application of in situ bioremediation is the effective distribution of nutrients to the subsurface media. Pneumatic fracturing can increase the permeability of subsurface formations through the injection of high pressure air to create horizontal fracture planes, thus enhancing macro-scale mass-transfer processes. Pneumatic fracturing technology was demonstrated at two field sites at Tinker Air Force Base, Oklahoma City, Oklahoma. Tests were performed to increase the permeability for more effective bioventing, and evaluated the potential to increase permeability and recovery of free product in low permeability soils consisting of fine grain silts, clays, and sedimentary rock. Pneumatic fracturing significantly improved formation permeability by enhancing secondary permeability and by promoting removal of excess soil moisture from the unsaturated zone. Postfracture airflows were 500% to 1,700% higher than prefracture airflows for specific fractured intervals in the formation. This corresponds to an average prefracturing permeability of 0.017 Darcy, increasing to an average of 0.32 Darcy after fracturing. Pneumatic fracturing also increased free-product recovery rates of number 2 fuel from an average of 587 L (155 gal) per month before fracturing to 1,647 L (435 gal) per month after fracturing.

  12. PNEUMATIC FRACTIONATOR FOR CLEANING GINNED LINT

    USDA-ARS?s Scientific Manuscript database

    The pneumatic fractionator has long been used to determine foreign matter content of seed cotton at the USDA Cotton Ginning Laboratories. Spawned from discussions at a Cotton Incorporated Lint Cleaning Summit and building on 1970s research at the Southwestern Cotton Ginning Research Laboratory, an e...

  13. Pneumatics. Student's Manual [and] Instructor's Guide.

    ERIC Educational Resources Information Center

    Notgrass, Troy

    The student's manual in this two-part instructional kit is designed to help the following types of students learn introductory technical material related to pneumatics: (1) groups of trade and industrial students with a variety of vocational objectives and (2) homogeneous groups in which the learning levels of individual students vary…

  14. Evaluation of neutron flux parameters in irradiation sites of research reactor using the Westcott-formalism for the k0 neutron activation analysis method

    NASA Astrophysics Data System (ADS)

    Kasban, H.; Hamid, Ashraf

    2015-12-01

    Instrumental Neutron Activation Analysis using k0 (k0-INAA) method has been used to determine a number of elements in sediment samples collected from El-Manzala Lake in Egypt. k0-INAA according to Westcott's formalism has been implemented using the complete irradiation kit of the fast pneumatic rabbit and some selected manually loaded irradiation sites for short and long irradiation at Egypt Second Research Reactor (ETRR-2). Zr-Au and Co sets as neutron flux monitors are used to determine the neutron flux parameters (f and α) in each irradiation sites. Two reference materials IAEA Soil-7 samples have been inserted and implemented for data validation and an internal monostandard multi monitor used (k0 based IM-NAA). It was given a good agreement between the experimental analyzed values and that obtained of the certified values. The major and trace elements in the sediment samples have been evaluated with the use of Co as an internal and Au as an external monostandard comparators. The concentrations of the elements (Cr, Mn and Zn) in the sediment samples of the present work are discussed regarding to those obtained from other sites.

  15. Myocardial hydroxyproline reduced by early administration of methylprednisolone or ibuprofen to rabbits with radiation-induced heart disease

    SciTech Connect

    Reeves, W.C.; Cunningham, D.; Schwiter, E.J.; Abt, A.; Skarlatos, S.; Wood, M.A.; Whitesell, L.

    1982-05-01

    The ability of methylprednisolone (MP) and ibuprofen (IB) to reduce the severity of the late state of radiation-induced heart disease was assessed in 57 New Zealand white rabbits. Before and shortly after cardiac irradiation, 15 rabbits received i.v. MP, 30 mg/kg twice daily for 3 days, and 15 others received IB, 12.5 mg/kg twice daily for 2 days. No drug administered to 14 irradiated rabbits, and neither irradiation nor drugs were administered to 13 rabbits that served as controls. All 15 rabbits treated with MP and 13 of the 15 treated with IB lived for 100 days. Only seven of the untreated, irradiated rabbits lived that long. Longevity of each treated group of rabbits was better (p < 0.01 and 0.05) than that of the untreated, irradiated rabbits. Surviving rabbits were killed 100 days after irradiation. Pericarditis (p < 0.05) and pericardial effusion (p < 0.01) were less frequent in the treated, irradiated groups than in the untreated, irradiated rabbits. At least some rabbits in each irradiated group had microscopic evidence of myocardial fibrosis. The fibrosis was quantitated by determination of myocardial hydroxyproline concentrations (MHP). MHP concentration in the untreated, irradiated rabbits was greater than in those treated with MP (p < 0.05) or IB (p < 0.01) and in the untreated, unirradiated rabbits (p < 0.01). Early administrative of MP or IB retarded the development of myocardial fibrosis, pericarditis and pericardial effusin, and improved survival in this experimental model of radiation-induced heart disease.

  16. Myocardial hydroxyproline reduced by early administration of methylprednisolone or ibuprofen to rabbits with radiation-induced heart disease

    SciTech Connect

    Reeves, W.C.; Cunningham, D.; Schwiter, E.J.; Abt, A.; Skarlatos, S.; Wood, M.A.; Whitesell, L.

    1982-05-01

    The ability of methylprednisolone (MP) and ibuprofen (IB) to reduce the severity of the late state of radiation-induced heart disease was assessed in 57 New Zealand white rabbits. Before and shortly after cardiac irradiation, 15 rabbits received i.v. MP, 30 mg/kg twice daily for 3 days, and 15 others received IB, 12.5 mg/kg twice daily for 2 days. No drug was administered to 14 irradiated rabbits, and neither irradiation nor drugs were administered to 13 rabbits that served as controls, All 15 rabbits treated with MP and 13 of the 15 treated with IB lived for 100 days. Only seven of the untreated, irradiated rabbits lived that long. Longevity of each treated group of rabbits was better (p less than 0.01 and 0.05) than that of the untreated, irradiated rabbits. Surviving rabbits were killed 100 days after irradiation. Pericarditis (p less than 0.05) and pericardial effusion (p less than 0.01) were less frequent in the treated, irradiated groups than in the untreated, irradiated rabbits. At least some rabbits in each irradiated group had microscopic evidence of myocardial fibrosis. The fibrosis was quantitated by determination of myocardial hydroxyproline concentrations (MHP). MHP concentration in the untreated, irradiated rabbits was greater than in those treated with MP (p less than 0.05) or IB (p less than 0.01) and in the untreated, unirradiated rabbits (p less than 0.01). Early administration of MP or IB retarded the development of myocardial fibrosis, pericarditis and pericardial effusion, and improved survival in this experimental model of radiation-induced heart disease.

  17. Pneumatically Actuated Miniature Peristaltic Vacuum Pumps

    NASA Technical Reports Server (NTRS)

    Feldman, Sabrina; Feldman, Jason; Svehla, Danielle

    2003-01-01

    Pneumatically actuated miniature peristaltic vacuum pumps have been proposed for incorporation into advanced miniature versions of scientific instruments that depend on vacuum for proper operation. These pumps are expected to be capable of reaching vacuum-side pressures in the torr to millitorr range (from .133 down to .0.13 Pa). Vacuum pumps that operate in this range are often denoted roughing pumps. In comparison with previously available roughing pumps, these pumps are expected to be an order of magnitude less massive and less power-hungry. In addition, they would be extremely robust, and would operate with little or no maintenance and without need for oil or other lubricants. Portable mass spectrometers are typical examples of instruments that could incorporate the proposed pumps. In addition, the proposed pumps could be used as roughing pumps in general laboratory applications in which low pumping rates could be tolerated. The proposed pumps could be designed and fabricated in conventionally machined and micromachined versions. A typical micromachined version (see figure) would include a rigid glass, metal, or plastic substrate and two layers of silicone rubber. The bottom silicone layer would contain shallow pump channels covered by silicone arches that could be pushed down pneumatically to block the channels. The bottom silicone layer would be covered with a thin layer of material with very low gas permeability, and would be bonded to the substrate everywhere except in the channel areas. The top silicone layer would be attached to the bottom silicone layer and would contain pneumatic- actuation channels that would lie crosswise to the pump channels. This version is said to be micromachined because the two silicone layers containing the channels would be fabricated by casting silicone rubber on micromachined silicon molds. The pneumatic-actuation channels would be alternately connected to a compressed gas and (depending on pump design) either to atmospheric

  18. RABBIT POX

    PubMed Central

    Rosahn, Paul D.; Hu, Ch'uan-K'uei

    1935-01-01

    Observations on an epidemic of rabbit pox occurring in an isolated animal room during the winter of 1933–34 are reported. The clinical manifestations, consisting of a generalized papular eruption involving the skin and mucous membranes, together with blepharitis, ophthalmia, nasal discharge and lymphadenopathy were essentially similar to those noted in a pox epidemic of the previous year. This was true in general also of the pathological findings except that vacuolization, local necrosis and vesicle formation were seen in the epidermis, while in the previous year the microscopic pathology in the skin was confined to the corium. Evidence was presented indicating that the infection can be transmitted through the medium of a personal carrier, and that transmission in this manner can occur during the incubation period or before a definite diagnosis is possible. The findings also demonstrated that the etiological agents responsible for the disease reported here and that of the previous year were immunologically related, and that the immunity in recovered animals effectively persisted during the entire period for which data are available, 9 to 12 months. It appeared also that young animals suckling an immune doe were more refractory to the development of the lesions of rabbit pox than were the young of susceptible does. PMID:19870418

  19. Pneumatic conveying of materials at partial gravity

    NASA Technical Reports Server (NTRS)

    Sullivan, Thomas A.; Koenig, Elissa; Knudsen, Christian W.; Gibson, Michael A.

    1992-01-01

    The feasibility of pneumatic transfer for the movement of regolith at a lunar base is evaluated. Operation of pneumatic conveying systems at partial (lunar and Mars) gravity on NASA's KC-135 aircraft allowed the determination of some key parameters necessary for the design of an operable system. Both horizontal and vertical transfer is studied. In the vertical experiment, the choking velocity for 150-micron glass spheres was determined to be 1/2 to 1/3 the velocity required at 1 g. Pressure drops were reduced by roughly the same amount. Determination of the saltation velocity in the horizontal run was problematic, but qualitatively similar results were obtained. Comparison of the partial g results to 1-g behavior and theoretical analysis is made.

  20. A pneumatic cylinder driving polyhedron mobile mechanism

    NASA Astrophysics Data System (ADS)

    Ding, Wan; Kim, Sung-Chan; Yao, Yan-An

    2012-03-01

    A novel pneumatic cylinder driving polyhedron mobile mechanism is proposed in this paper. The mechanism is comprised of 5 tetrahedrons which includes a pneumatic cylinder in each edge. It locomotes by rolling and the rolling principle refers to the center of mass (CM) of the mechanism moved out of the supporting area and let it tip over through the controlling of the motion sequence of these cylinders. Firstly, the mathematical model is built to analysis the relation between the configuration and the CM of the mechanism. Then, a binary control strategy is developed to simplify and improve the control of this mobile mechanism. After that, dynamic simulation is performed to testify the analytical validity and feasibility of the rolling gaits. At last, a prototype is fabricated to achieve the rolling successfully to demonstrate the proposed concept.

  1. Pneumatic conveying of materials at partial gravity

    NASA Technical Reports Server (NTRS)

    Sullivan, Thomas A.; Koenig, Elissa; Knudsen, Christian W.; Gibson, Michael A.

    1992-01-01

    The feasibility of pneumatic transfer for the movement of regolith at a lunar base is evaluated. Operation of pneumatic conveying systems at partial (lunar and Mars) gravity on NASA's KC-135 aircraft allowed the determination of some key parameters necessary for the design of an operable system. Both horizontal and vertical transfer is studied. In the vertical experiment, the choking velocity for 150-micron glass spheres was determined to be 1/2 to 1/3 the velocity required at 1 g. Pressure drops were reduced by roughly the same amount. Determination of the saltation velocity in the horizontal run was problematic, but qualitatively similar results were obtained. Comparison of the partial g results to 1-g behavior and theoretical analysis is made.

  2. Pneumatic Proboscis Heat-Flow Probe

    NASA Technical Reports Server (NTRS)

    Zacny, Kris; Hedlund, Magnus; Mumm, Eric; Shasho, Jeffrey; Chu, Philip; Kumar, Nishant

    2013-01-01

    Heat flow is a fundamental property of a planet, and provides significant constraints on the abundance of radiogenic isotopes, the thermal evolution and differentiation history, and the mechanical properties of the lithosphere. Heat-flow measurements are also essential in achieving at least four of the goals set out by the National Research Council for future lunar exploration. The heat-flow probe therefore directly addresses the goal of the Lunar Geophysical Network, which is to understand the interior structure and composition of the Moon. A key challenge for heat flow measurement is to install thermal sensors to the depths approximately equal to 3 m that are not influenced by the diurnal, annual, and longer-term fluctuations of the surface thermal environment. In addition, once deployed, the heat flow probe should cause little disturbance to the thermal regime of the surrounding regolith. A heat-flow probe system was developed that has two novel features: (1) it utilizes a pneumatic (gas) approach, excavates a hole by lofting the lunar soil out of the hole, and (2) deploys the heat flow probe, which utilizes a coiled up tape as a thermal probe to reach greater than 3-meter depth. The system is a game-changer for small lunar landers as it exhibits extremely low mass, volume, and simple deployment. The pneumatic system takes advantage of the helium gas used for pressurizing liquid propellant of the lander. Normally, helium is vented once the lander is on the surface, but it can be utilized for powering pneumatic systems. Should sufficient helium not be available, a simple gas delivery system may be taken specifically for the heat flow probe. Either way, the pneumatic heat flow probe system would be much lighter than other systems that entirely rely on the electrical power of the lander.

  3. Pneumatic preloaded scanning science launch latch system

    NASA Technical Reports Server (NTRS)

    Kievit, J. C.

    1979-01-01

    A relatively simple system using a preloaded pneumatic piston latch with a pyrotechnic valve release was developed. The system was the only candidate that met all the imposed requirements utilizing reliable state-of-art components. The development of the latch system from its first use on Mariner '69 Mars Flyby Spacecraft through its most recent use on the Voyager Spacecraft that will fly to Jupiter and Saturn is reviewed.

  4. Internal Ballistics of a Pneumatic Potato Cannon

    DTIC Science & Technology

    2009-03-09

    IOP PUBLISHING EUROPEAN JOURNAL OF PHYSICS Eur. J. Phys. 30 (2009) 453–457 doi:10.1088/0143-0807/30/3/003 Internal ballistics of a pneumatic potato ...an air gun. Such devices are often employed in outdoor physics demonstrations to launch potatoes using compressed gas that is here assumed to expand...undergraduate students who have taken calculus-based introductory physics. Potato cannons are a popular construction project for physics demonstrations

  5. Development of the prototype pneumatic transfer system for ITER neutron activation systema)

    NASA Astrophysics Data System (ADS)

    Cheon, M. S.; Seon, C. R.; Pak, S.; Lee, H. G.; Bertalot, L.

    2012-10-01

    The neutron activation system (NAS) measures neutron fluence at the first wall and the total neutron flux from the ITER plasma, providing evaluation of the fusion power for all operational phases. The pneumatic transfer system (PTS) is one of the key components of the NAS for the proper operation of the system, playing a role of transferring encapsulated samples between the capsule loading machine, irradiation stations, counting stations, and disposal bin. For the validation and the optimization of the design, a prototype of the PTS was developed and capsule transfer tests were performed with the developed system.

  6. Pneumatic compression hemodynamics in total hip arthroplasty.

    PubMed

    Westrich, G H; Specht, L M; Sharrock, N E; Sculco, T P; Salvati, E A; Pellicci, P M; Trombley, J F; Peterson, M

    2000-03-01

    A crossover study was performed to evaluate the effect of several pneumatic compression devices and active dorsoplantar flexion in 10 patients who underwent total hip arthroplasty. Using the Acuson 128XP/10 duplex ultrasound unit with a 5-MHz linear array probe, peak venous velocity and venous volume were assessed above and below the greater saphenous vein and common femoral vein junction. A computer generated randomization table was used to determine the order of the test conditions. The pneumatic compression devices evaluated included two foot pumps, one foot and calf pump, one calf pump, and three calf and thigh pumps. Statistical analyses included analysis of variance and analysis of variance with covariance between devices and patients. The covariates tested were the baseline measurements and the order in which the devices were tested. Differences between devices relate in part to the frequency and rate of inflation and the location and type of compression. Pulsatile calf and foot and calf pneumatic compression with a rapid inflation time produced the greatest increase in peak venous velocity, whereas compression of the calf and thigh showed the greatest increase in venous volume. Because patient and nursing compliance is essential to the success of mechanical prophylaxis for thromboembolic disease, the more simple, yet efficacious, devices that are easier to apply and less cumbersome appear to have a greater likelihood of success. In the active and alert patient, active dorsoplantar flexion should be encouraged.

  7. Paranasal pneumatization in extant and fossil Cercopithecoidea.

    PubMed

    Rae, Todd C

    2008-03-01

    Unlike most primates, extant cercopithecoids lack maxillary sinuses, which are pneumatic spaces in the facial skeleton lateral of the nasal cavity proper. Character state analysis of living cercopithecoids across well-supported topologies suggests that the sinus was lost at the origin of the superfamily, only to have evolved again convergently in extant macaques. Recent work has shown that a) the 'early loss' hypothesis is supported by the lack of any pneumatization in Victoriapithecus, a stem cercopithecoid, b) like extant macaques, the fossil cercopithecine Paradolichopithecus shows evidence of presence of the maxillary sinus (MS), and c) unlike extant colobines, the fossil colobine Libypithecus also possesses a maxillary sinus. To more fully assess the pattern of cercopithecoid sinus evolution, fossil taxa from both subfamilies (Colobinae, Cercopithecinae) were examined both visually and by computed tomography (CT). The observations were evaluated according to standard anatomical criteria for defining sinus spaces, and compared with data from all extant Old World monkey genera. Most taxa examined conformed to the pattern already discerned from extant cercopithecoids. Maxillary sinus absence in Theropithecus oswaldi, Mesopithecus, and Rhinocolobus is typical for all extant cercopithecids except Macaca. The fossil macaque Macaca majori possesses a well-developed maxillary sinus, as do all living species of the genus. Cercopithecoides, on the other hand, differs from all extant colobines in possessing a maxillary sinus. Thus, paranasal pneumatization has reemerged a minimum of two and possibly three times in cercopithecoids. The results suggest that maxillary sinus absence in cercopithecoids is due to suppression, rather than complete loss.

  8. Comparison of pneumatic dilation with pneumatic dilation plus botulinum toxin for treatment of achalasia.

    PubMed

    Bakhshipour, Alireza; Rabbani, Romina; Shirani, Shapoor; Soleimani, Hosein A S L; Mikaeli, Javad

    2010-01-01

    Among the therapeutic options for achalasia are pneumatic dilatation (PD), an appropriate long-term therapy, and botulinum toxin injection (BT) that is a relatively short-term therapy. This study aimed to compare therapeutic effect of repetitive pneumatic dilation with a combined method (botulinum toxin injection and pneumatic dilation) in a group of achalasia patients who are low responder to two initial pneumatic dilations. Thirty-four patients with documented primary achalasia that had low response to two times PD (<50% decrease in symptom score and barium height at 5 minute in timed esophagogram after 3 month of late PD) were randomized to receive pneumatic dilation (n=18) or botulinum toxin injection and pneumatic dilation by four weeks interval (n=16), PD and BT+PD groups respectively. Symptom scores were evaluated before and at 1, 6 and 12 months after treatment. Clinical remission was defined as a decrease in symptom score > or = 50% of baseline. There were no significant differences between the two groups in gender, age and achalasia type. Remission rate of patients in BT-PD group in comparison with PD group were 87.5% vs. 67.1% (P = 0.7), 87.5% vs. 61.1% (P = 0.59) and 87.5% vs. 55.5% (P = 0.53) at 1, 6 and 12 months respectively .There were no major complications in either group. The mean symptom score decreased by 62.71% in the BT-PD group (P < 0.002) and 50.77% in the PD group (P < 0.01) at the end of the first year. Despite a better response rate in BT+PD group, a difference was not statistically significant. A difference may be meaningful if a large numbers of patients are included in the study.

  9. Modification of the rotary specimen rack (Lazy Susan) at the U.S. Geological Survey TRIGA Reactor (GSTR) to permit pneumatic unloading of samples

    SciTech Connect

    Heifer, P.G.; Rusling, D.H.

    1986-07-01

    With a continuing sample load of about 18,000 samples per year, the U.S.G.S. TRIGA facility has installed a modified rotary specimen rack that allows samples to be unloaded from the rack using a closed loop blower system. The radiation exposure to operating personnel is lowered due to remote operation. Time required to unload large numbers of samples is reduced dramatically, and the sample capacity of the lazy susan can be doubled due to design changes of the. irradiation capsule allowed by the pneumatic unloading system. The safety, versatility, time and costs are improved by the addition of the pneumatic unloading lazy susan. (author)

  10. Incidence, radioresistance, and behavior of Psychrobacter spp. in rabbit meat.

    PubMed

    Rodríguez-Calleja, José M; Patterson, Margaret F; García-López, Isabel; Santos, Jesús A; Otero, Andrés; García-López, María-Luisa

    2005-03-01

    The relative incidence of Psychrobacter spp. in rabbit meat, the radioresistance of these bacteria, and the growth of nonirradiated and irradiated psychrobacter isolates, alone and in coculture, during chilled storage of inoculated sterile rabbit meat was investigated. Psychrobacter spp. accounted for 4.2% of the storage psychrotrophic flora of 30 rabbit carcasses. The radiation D10-values of 10 Psychrobacter isolates, irradiated at 4 degrees C in minced rabbit meat, ranged from 0.8 to 2.0 kGy, with significant (P < 0.05) differences among strains. Over 12 days of storage at 4 degrees C, pure cultures of two nonirradiated psychrobacter strains (D10 = 2 kGy) were capable of substantial increases (up to 3 log CFU/g) in sterile rabbit meat, but when the fastest growing strain was cocultured with Pseudomonas fluorescens and Brochothrix thermosphacta isolates, maximum cell densities and growth rates were significantly (P < 0.01) lower. After irradiation (2.5 kGy) of pure cultures in sterile rabbit meat, surviving cells of both Psychrobacter strains decreased for a period of 5 to 7 days and then resumed multiplication that, at day 12, resulted in a similar increase (1.6 to 1.7 log CFU/g) over initial survivor numbers. When irradiated in combination with the spoilage bacteria, one of the strains required 12 days to reach initial numbers. In conclusion, Psychrobacter spp. are radioresistant nonsporeforming bacteria with a low relative incidence among the storage flora of rabbit meat, unable to compete with food spoilage bacteria in this ecosystem and apparently not a major contributor to the spoilage of rabbit meat after irradiation.

  11. Viral infections of rabbits.

    PubMed

    Kerr, Peter J; Donnelly, Thomas M

    2013-05-01

    Viral diseases of rabbits have been used historically to study oncogenesis (e.g. rabbit fibroma virus, cottontail rabbit papillomavirus) and biologically to control feral rabbit populations (e.g. myxoma virus). However, clinicians seeing pet rabbits in North America infrequently encounter viral diseases although myxomatosis may be seen occasionally. The situation is different in Europe and Australia, where myxomatosis and rabbit hemorrhagic disease are endemic. Advances in epidemiology and virology have led to detection of other lapine viruses that are now recognized as agents of emerging infectious diseases. Rabbit caliciviruses, related to rabbit hemorrhagic disease, are generally avirulent, but lethal variants are being identified in Europe and North America. Enteric viruses including lapine rotavirus, rabbit enteric coronavirus and rabbit astrovirus are being acknowledged as contributors to the multifactorial enteritis complex of juvenile rabbits. Three avirulent leporid herpesviruses are found in domestic rabbits. A fourth highly pathogenic virus designated leporid herpesvirus 4 has been described in Canada and Alaska. This review considers viruses affecting rabbits by their clinical significance. Viruses of major and minor clinical significance are described, and viruses of laboratory significance are mentioned. Copyright © 2013 Elsevier Inc. All rights reserved.

  12. Web-Based Learning and Instruction Support System for Pneumatics

    ERIC Educational Resources Information Center

    Yen, Chiaming; Li, Wu-Jeng

    2003-01-01

    This research presents a Web-based learning and instructional system for Pneumatics. The system includes course material, remote data acquisition modules, and a pneumatic laboratory set. The course material is in the HTML format accompanied with text, still and animated images, simulation programs, and computer aided design tools. The data…

  13. Web-Based Learning and Instruction Support System for Pneumatics

    ERIC Educational Resources Information Center

    Yen, Chiaming; Li, Wu-Jeng

    2003-01-01

    This research presents a Web-based learning and instructional system for Pneumatics. The system includes course material, remote data acquisition modules, and a pneumatic laboratory set. The course material is in the HTML format accompanied with text, still and animated images, simulation programs, and computer aided design tools. The data…

  14. 49 CFR 236.837 - Valve, electro-pneumatic.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Valve, electro-pneumatic. 236.837 Section 236.837 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION... Valve, electro-pneumatic. A valve electrically operated which, when operated, will permit or prevent...

  15. Evaluating a pneumatic fractionator for cleaning ginned lint

    USDA-ARS?s Scientific Manuscript database

    The pneumatic fractionator has long been used to determine foreign matter content of seed cotton at the USDA Cotton Ginning Laboratories. An experiment was conducted to evaluate the pneumatic fractionator as a lint cleaning device. No modifications were made to the standard device, except that air p...

  16. Long term results of pneumatic retinopexy

    PubMed Central

    Ellakwa, Amin F

    2012-01-01

    Background Rhegmatogenous retinal detachment is a commonly encountered retinal problem where rapid treatment can prevent irreversible vision loss. Pneumatic retinopexy (PR) is a simple, minimally invasive procedure for retinal reattachment. Purpose This study aimed to assess the long-term anatomical and functional outcome of pneumatic retinopexy in primary rhegmatogenous retinal detachment. Patients and methods A prospective interventional study was performed. Subjects with rhegmatogenous retinal detachment who underwent pneumatic retinopexy from May 2006 to May 2007 at Menoufiya University Hospital were included in this study with at least 3 years follow-up. Results A total of 40 cases were included in the study. The mean age of patients was 44.25 ± 10.85 years. Reattachment of the retina was achieved in 100% of cases. In 75% of cases, the primary intervention was successful. However, the retina redetached in 20% of these during the first 6 months, requiring reinjection or another procedure. Three years after the first intervention, follow-up measurement of the mean visual acuity of the eyes without reoperation was 0.40 ± 0.21 while the mean visual acuity of the eyes which needed additional operations was 0.22 ± 0.13. Conclusion Sixty percent of the cases obtained long-term retinal reattachment with a single operation success (SOS), with good visual recovery and less morbidity than other more invasive procedures like scleral buckling or pars plana vitrectomy, translating to higher productivity for the patient. This procedure, being quicker than the alternatives, also saves the surgeon’s time, making PR a good choice for managing primary rhegmatogenous retinal detachment in developing countries. PMID:22275808

  17. An electromagnetic pneumatic blood pump driver.

    PubMed

    Whalen, R L; Briskman, R N

    1988-01-01

    An electromagnetic pneumatic pump driver has been developed with the goals of enhanced mechanical reliability and simplicity of operation. The new driver eliminates failure prone components such as solenoid valves or pressure regulators common to conventional pneumatic drive systems, has only a single moving part, and provides for closed-loop operation in which stroke volume and dP/dT are controlled on each beat in real time. Power is provided by a high force (178 N) electromagnetic linear actuator. This assembly uses a high energy density neodymium-iron-boron permanent magnet, low loss vanadium alloy pole pieces, and an energized moving coil. The nominal stroke length of the actuator is 1.7 cm. During operation, the moving coil always remains within a fixed annular air gap, resulting in a measured force output versus applied power linearity of better than 92% over its stroke range. The coil is directly attached to the free end of a 10 cm diameter, 21 convolution, welded titanium metal bellows that forms the gas containing element of the system. The comparatively low pressure gradients across the bellows in this application result in a predicted life for the bellows in excess of 10(9) cycles. Bellows position and internal pressure are monitored continuously to control the pneumatic output. The linear actuator total excursion and velocity are adjusted on each beat using a closed-loop servo system. This results in a pump driver with no operator required adjustment of drive pressure. Instead, there are user selected settings of stroke volume, operating mode, and fill sensitivity.(ABSTRACT TRUNCATED AT 250 WORDS)

  18. Hemolysis associated with pneumatic tube system transport for blood samples.

    PubMed

    Kara, Hasan; Bayir, Aysegul; Ak, Ahmet; Degirmenci, Selim; Akinci, Murat; Agacayak, Ahmet; Marcil, Emine; Azap, Melih

    2014-01-01

    The frequency of hemolysis of blood samples may be increased by transport in a pneumatic tube system. The purpose of this study was to evaluate the effect of pneumatic tube system transport on hemolysis of blood samples. Blood samples were transported from the emergency department to the hospital laboratory manually by hospital staff (49 patients) or with a pneumatic tube system (53 patients). The hemolysis index and serum chemistry studies were performed on the blood samples and compared between the different methods of transport. The blood samples that were transported by the pneumatic tube system had a greater frequency of hemolysis and greater mean serum potassium and median creatinine, aspartate aminotransferase, and lactate dehydrogenase levels than samples transported manually. Blood samples transported from the emergency department to the hospital laboratory by a pneumatic tube system may have a greater frequency of hemolysis than samples transported manually. This may necessitate repeat phlebotomy and cause a delay in completing the laboratory analysis.

  19. A comparison between two pneumatic suspension architectures

    NASA Astrophysics Data System (ADS)

    Quaglia, G.; Scopesi, M.; Franco, W.

    2012-04-01

    The aim of this work is to assess and compare the mathematical models of two pneumatic suspension architectures and show how they can converge, after appropriate simplifications, to a general linear form. After making this model dimensionless, it will be used to study, with a transmissibility analysis, the behaviour of a mono-suspension (quarter-car model). Finally, an example of a design process will be shown to highlight the strengths and weaknesses of both architectures and to provide the reader with a practical design tool.

  20. Pneumatic Artificial Muscle Actuation and Modeling

    NASA Astrophysics Data System (ADS)

    Leephakpreeda, Thananchai; Wickramatunge, Kanchana C.

    2009-10-01

    A Pneumatic Artificial Muscle (PAM) yields a natural muscle-like actuator with a high force to weight ratio, a soft and flexible structure, and adaptable compliance for a humanoid robot, rehabilitation and prosthetic appliances to the disabled, etc. To obtain optimum design and usage, the mechanical behavior of the PAM need to be understood. In this study, observations of experimental results reveal an empirical model for relations of physical variables, contraction and air pressure within the PAM, as compared to mechanical characteristics, such as stiffness or/and pulling forces of the PAM available now in market.

  1. [Pneumatic dilation in the treatment of achalasia].

    PubMed

    Ruiz Cuesta, Patricia; Hervás Molina, Antonio José; Jurado García, Juan; Pleguezuelo Navarro, María; García Sánchez, Valle; Casáis Juanena, Luis L; Gálvez Calderón, Carmen; Naranjo Rodríguez, Antonio

    2013-10-01

    Pneumatic dilation and surgical myotomy are currently the procedures of choice to treat achalasia. The selection of one or other treatment depends on the experience of each center and patient preferences. To review the experience of pneumatic dilation in patients with achalasia in our center. We included all patients with a clinical, endoscopic and manometric diagnosis compatible with achalasia who underwent pneumatic dilation in a 19-year period. All dilations were routinely performed with a Rigiflex(®) balloon, usually at pressures of 250, 250 and 300mm Hg in three inflations of one minute, each separated by one minute. The success of the dilation was assessed on the basis of the patient's symptoms, the number of sessions, the need for surgery, and the presence of complications. A total of 171 patients were included, 53.2% men and 46.8% women, with a mean age of 51.53±17.78 years (16-87 years), from June 1993 to October 2012. A 35-mm balloon was used in 157 patients, a 30-mm balloon in 9 patients and a 40-mm balloon in 7 patients. A single dilation session was required in 108 patients, two sessions were required in 56 patients, with a mean time between the first and second sessions of 25.23±43.25 months (1-215 months), and 3 sessions were required in 7 patients with a mean time between the second and third sessions of 6.86±5.33 months (1-15 months). Outcome after dilation was successful in 81% of the patients. Of the 140 responders, 121 had complete response (complete disappearance of symptoms without recurrence) and 19 partial response (initial disappearance of symptoms with subsequent reappearance). Surgery (Heller myotomy) was required in 15.8% of the patients. Perforation occurred in 4 of the 171 patients as a complication of the technique; these perforations were satisfactorily resolved, two by conservative treatment and two by surgery. There was no mortality associated with the technique or its complications. In our series, pneumatic dilation had a

  2. Revisiting Pneumatic Nail Gun Trigger Recommendations.

    PubMed

    Albers, James; Lowe, Brian; Lipscomb, Hester; Hudock, Stephen; Dement, John; Evanoff, Bradley; Fullen, Mark; Gillen, Matt; Kaskutas, Vicki; Nolan, James; Patterson, Dennis; Platner, James; Pompeii, Lisa; Schoenfisch, Ashley

    2015-03-01

    Use of a pneumatic nail gun with a sequential actuation trigger (SAT) significantly diminishes the risk for acute traumatic injury compared to use of a contact actuation trigger (CAT) nail gun. A theoretically-based increased risk of work-related musculoskeletal disorders from use of a SAT nail gun, relative to CAT, appears unlikely and remains unproven. Based on current knowledge, the use of CAT nail guns cannot be justified as a safe alternative to SAT nail guns. This letter provides a perspective of ergonomists and occupational safety researchers recommending the use of the sequential actuation trigger for all nail gun tasks in the construction industry.

  3. Revisiting Pneumatic Nail Gun Trigger Recommendations

    PubMed Central

    Albers, James; Lipscomb, Hester; Hudock, Stephen; Dement, John; Evanoff, Bradley; Fullen, Mark; Gillen, Matt; Kaskutas, Vicki; Nolan, James; Patterson, Dennis; Platner, James; Pompeii, Lisa; Schoenfisch, Ashley

    2015-01-01

    Summary Use of a pneumatic nail gun with a sequential actuation trigger (SAT) significantly diminishes the risk for acute traumatic injury compared to use of a contact actuation trigger (CAT) nail gun. A theoretically-based increased risk of work-related musculoskeletal disorders from use of a SAT nail gun, relative to CAT, appears unlikely and remains unproven. Based on current knowledge, the use of CAT nail guns cannot be justified as a safe alternative to SAT nail guns. This letter provides a perspective of ergonomists and occupational safety researchers recommending the use of the sequential actuation trigger for all nail gun tasks in the construction industry. PMID:26366020

  4. Pneumatic tire-based piezoelectric power generation

    NASA Astrophysics Data System (ADS)

    Makki, Noaman; Pop-Iliev, Remon

    2011-03-01

    Plug-in Hybrid Electric Vehicles (PHEVs) and Extended Range Electric Vehicles (EREVs) currently mainly rely on Internal Combustion Engines (ICE) utilizing conventional fuels to recharge batteries in order to extend their range. Even though Piezo-based power generation devices have surfaced in recent years harvesting vibration energy, their output has only been sufficient to power up sensors and other such smaller devices. The permanent need for a cleaner power generation technique still remains. This paper investigates the possibility of using piezoceramics for power generation within the vehicle's wheel assembly by exploiting the rotational motion of the wheel and the continuously variable contact point between the pneumatic tire and the road.

  5. 46 CFR 54.10-15 - Pneumatic test (modifies UG-100).

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 2 2010-10-01 2010-10-01 false Pneumatic test (modifies UG-100). 54.10-15 Section 54.10... VESSELS Inspection, Reports, and Stamping § 54.10-15 Pneumatic test (modifies UG-100). (a) Pneumatic...) Except for enameled vessels, for which the pneumatic test pressure shall be at least equal to, but need...

  6. Axial and appendicular pneumaticity in Archaeopteryx.

    PubMed Central

    Christiansen, P; Bonde, N

    2000-01-01

    From the time of its discovery in 1860 to this day Archaeopteryx has been essential to our understanding of avian evolution. Despite the great diversity of plesiomorphic avialan (sensu Gauthier 1986) taxa discovered within the last decade, Archaeopteryx remains the most basal avialan taxon. A very unusual feature of extant birds is their lung structure, in which air diverticulae penetrate the bones. This has previously been reported in Archaeopteryx as well, in the cervical vertebrae of the Berlin specimen and in an anterior thoracal vertebra of the Eichstätt specimen. This indicates the presence of a cervical air sac. We show that the London specimen also has pneumatized anterior thoracal vertebrae, and, thus, that this feature was present in the most archaic avialans, as the London and Eichstätt specimens are different species. Furthermore, the pelvis of the London specimen shows clear signs of the presence of an abdominal air sac, indicating that at least two of the five air sacs present in modern birds were also present in Archaeopteryx. Evidence of pubic pneumaticity was also found in the same position in some extant ratites. PMID:11197125

  7. Pneumatic load compensating or controlling system

    NASA Technical Reports Server (NTRS)

    Rogers, J. R. (Inventor)

    1975-01-01

    A pneumatic load compensating or controlling system for restraining a load with a predetermined force or applying a predetermined force to the load is described; it includes a source of pressurized air, a one-way pneumatic actuator operatively connected to a load, and a fluid conduit fluidically connecting the actuator with the source of pressurized air. The actuator is of the piston and cylinder type, and the end of the fluid conduit is connected to the upper or lower portion of the cylinder whereby the actuator alternatively and selectively restrains the load with a predetermined force or apply a predetermined force to the load. Pressure regulators are included within the system for variably selectively adjusting the pressurized fluid to predetermined values as desired or required; a pressure amplifier is included within the system for multiplying the pressurized values so as to achieve greater load forces. An accumulator is incorporated within the system as a failsafe operating mechanism, and visual and aural alarm devices, operatively associated with pressure detecting apparatus, readily indicate the proper or improper functioning of the system.

  8. Stacked pneumatic cylinders automate conveyor belt operations

    SciTech Connect

    Thornton, G.

    1982-11-01

    Shows how clusters of remotely controlled pneumatic cylinders swing a hinged conveyor belt to 4 preselected vertical positions. Using a manual method to move the conveyor meant that the operator had to use a hand winch, sheaves, drums, and winch cable. There was a need to develop a simple, effective, and remotely controlled system which would perform 2 functions: eliminate the need for stopping the conveyor to reset the hinged belt, and not require the operator to leave the master control console. Using the developed system, the operator need only turn on the appropriate switching valves from the master console. Each pneumatic cylinder is actuated in sequence, on the retraction stroke only, through the elevating positions. To lower the conveyor belt, the head end of each cylinder is exhausted; the weight of the belt extends the cylinders, lowering the belt by gravity. Cylinder exhaust ports in the power valves are fitted with adjustable flow control valves to regulate cylinder speed; common exhaust ports in the interconnected manifolds are fitted with air silencers.

  9. Transforming insect electromyograms into pneumatic muscle control

    NASA Astrophysics Data System (ADS)

    Rutter, Brandon; Mu, Laiyong; Ritzmann, Roy; Quinn, Roger

    2006-05-01

    Robots can serve as hardware models for testing biological hypotheses. Both for this reason and to improve the state of the art of robotics, we strive to incorporate biological principles of insect locomotion into robotic designs. Previous research has resulted in a line of robots with leg designs based on walking and climbing movements of the cockroach Blaberus discoidalis. The current version, Robot V, uses muscle-like Braided Pneumatic Actuators (BPAs). In this paper, we use recorded electromyograms (EMGs) to drive robot joint motion. A muscle activation model was developed that transforms EMGs recorded from behaving cockroaches into appropriate commands for the robot. The transform is implemented by multiplying the EMG by an input gain thus generating an input pressure signal, which is used to drive a one-way closed loop pressure controller. The actuator then can be modeled as a capacitance with input rectification. The actuator exhaust valve is given a leak rate, making the transform a leaky integrator for air pressure, which drives the output force of the actuator. We find parameters of this transform by minimizing the difference between the robot motion produced and that observed in the cockroach. Although we have not reproduced full-amplitude cockroach motion using this robot, results from evaluation on reduced-amplitude cockroach angle data strongly suggest that braided pneumatic actuators can be used as part of a physical model of a biological system.

  10. Pneumatic evoked potential. Sensory or auditive potential?

    PubMed

    Condé, S; Créac'h, C; Brun, X; Moreau, R; Convers, P; Peyron, R

    2013-06-01

    In this study, evoked potentials (EPs) to a pneumatic, innocuous, and calibrated stimulation of the skin were recorded in 22 volunteers. Air-puff stimuli were delivered through a home-made device (INSA de Lyon, Laboratoire Ampère, CHU de Saint-Étienne, France) synchronized with an EEG recording (Micromed(®)). A reproducible EP was recorded in 18 out of 22 subjects (82% of cases) with a mean latency of about 120-130ms, and maximal amplitude at Cz. This EP actually consisted of two components, an auditory and a somatosensory one. Indeed, it was significantly decreased in amplitude, but did not disappear, when the noise generated by the air-puff was masked. We also verified that a stimulation close to the skin but not perceived by the subject was not associated with any EP. Conduction velocity between hand and shoulder was calculated around 25m/s. This preliminary study demonstrates that pneumatic EPs can be recorded in normal volunteers. Copyright © 2013. Published by Elsevier SAS.

  11. Pneumatic pellet injector research at ORNL

    SciTech Connect

    Milora, S.L.; Combs, S.K.; Foster, C.A.; Schuresko, D.D.; Gouge, M.J.; Fisher, P.W.; Argo, B.E.; Barber, G.C.; Fehling, D.T.; Foust, C.R.

    1988-01-01

    Advanced pneumatic-injector-based pellet fueling systems are under development at Oak Ridge National Laboratory (ORNL) for fueling magnetically confined plasmas. The general approach is that of producing and accelerating frozen hydrogen isotope pellets at speeds in the range from 1 to 2 km/s and higher. Recently, ORNL provided pneumatic-based pellet fueling systems for the Tokamak Fusion Test Reactor (TFTR) and the Joint European Torus (JET), and a new simplified eight-shot injector has been developed for use on the Princeton Beta Experiment (PBX) and the Advanced Toroidal Facility (ATF). These long-pulse devices operate reliably at up to 1.5 km/s with pellet sizes ranging between 1 and 6 mm. In addition to these activities, ORNL is pursuing advanced technologies such as the electrothermal gun and the two-stage light-gas gun to achieve pellet velocities significantly in excess of 2 km/s and is carrying out a tritium proof-of-principle (TPOP) experiment in which the fabrication and acceleration of tritium pellets to 1.4 km/s were recently demonstrated. 27 refs., 10 figs.

  12. Scaling of pneumatic digital logic circuits.

    PubMed

    Duncan, Philip N; Ahrar, Siavash; Hui, Elliot E

    2015-03-07

    The scaling of integrated circuits to smaller dimensions is critical for achieving increased system complexity and speed. Digital logic circuits composed of pneumatic microfluidic components have to this point been limited to a circuit density of 2-4 gates cm(-2), constraining the complexity of the digital systems that can be achieved. We explored the use of precision machining techniques to reduce the size of pneumatic valves and resistors, and to achieve more accurate and efficient placement of ports and vias. In this way, we attained an order of magnitude increase in circuit density, reaching as high as 36 gates cm(-2). A 12-bit binary counter circuit composed of 96 gates was realized in an area of 360 mm(2). The reduction in size also brought an order of magnitude increase in speed. The frequency of a 13-stage ring oscillator increased from 2.6 Hz to 22.1 Hz, and the maximum clock frequency of a binary counter increased from 1/3 Hz to 6 Hz.

  13. Continued Development and Improvement of Pneumatic Heavy Vehicles

    SciTech Connect

    Robert J. Englar

    2005-07-15

    The objective of this applied research effort led by Georgia Tech Research Institute is the application of pneumatic aerodynamic technology previously developed and patented by us to the design of an appropriate Heavy Vehicle (HV) tractor-trailer configuration, and experimental confirmation of this pneumatic configuration's improved aerodynamic characteristics. In Phases I to IV of our previous DOE program (Reference 1), GTRI has developed, patented, wind-tunnel tested and road-tested blown aerodynamic devices for Pneumatic Heavy Vehicles (PHVs) and Pneumatic Sports Utility Vehicles (PSUVs). To further advance these pneumatic technologies towards HV and SUV applications, additional Phase V tasks were included in the first year of a continuing DOE program (Reference 2). Based on the results of the Phase IV full-scale test programs, these Phase V tasks extended the application of pneumatic aerodynamics to include: further economy and performance improvements; increased aerodynamic stability and control; and safety of operation of Pneumatic HVs. Continued development of a Pneumatic SUV was also conducted during the Phase V program. Phase V was completed in July, 2003; its positive results towards development and confirmation of this pneumatic technology are reported in References 3 and 4. The current Phase VI of this program was incrementally funded by DOE in order to continue this technology development towards a second fuel economy test on the Pneumatic Heavy Vehicle. The objectives of this current Phase VI research and development effort (Ref. 5) fall into two categories: (1) develop improved pneumatic aerodynamic technology and configurations on smaller-scale models of the advanced Pneumatic Heavy Vehicle (PHV); and based on these findings, (2) redesign, modify, and re-test the modified full-scale PHV test vehicle. This second objective includes conduct of an on-road preliminary road test of this configuration to prepare it for a second series of SAE Type-U fuel

  14. Variant rabbit hemorrhagic disease virus in young rabbits, Spain.

    PubMed

    Dalton, Kevin P; Nicieza, Inés; Balseiro, Ana; Muguerza, María A; Rosell, Joan M; Casais, Rosa; Álvarez, Ángel L; Parra, Francisco

    2012-12-01

    Outbreaks of rabbit hemorrhagic disease have occurred recently in young rabbits on farms on the Iberian Peninsula where rabbits were previously vaccinated. Investigation identified a rabbit hemorrhagic disease virus variant genetically related to apathogenic rabbit caliciviruses. Improved antivirus strategies are needed to slow the spread of this pathogen.

  15. Compensating for pneumatic distortion in pressure sensing devices

    NASA Technical Reports Server (NTRS)

    Whitmore, Stephen A.; Leondes, Cornelius T.

    1990-01-01

    A technique of compensating for pneumatic distortion in pressure sensing devices was developed and verified. This compensation allows conventional pressure sensing technology to obtain improved unsteady pressure measurements. Pressure distortion caused by frictional attenuation and pneumatic resonance within the sensing system makes obtaining unsteady pressure measurements by conventional sensors difficult. Most distortion occurs within the pneumatic tubing which transmits pressure impulses from the aircraft's surface to the measurement transducer. To avoid pneumatic distortion, experiment designers mount the pressure sensor at the surface of the aircraft, (called in-situ mounting). In-situ transducers cannot always fit in the available space and sometimes pneumatic tubing must be run from the aircraft's surface to the pressure transducer. A technique to measure unsteady pressure data using conventional pressure sensing technology was developed. A pneumatic distortion model is reduced to a low-order, state-variable model retaining most of the dynamic characteristics of the full model. The reduced-order model is coupled with results from minimum variance estimation theory to develop an algorithm to compensate for the effects of pneumatic distortion. Both postflight and real-time algorithms are developed and evaluated using simulated and flight data.

  16. The effect of pneumatic dilation in management of postfundoplication dysphagia.

    PubMed

    Sunjaya, D; Podboy, A; Blackmon, S H; Katzka, D; Halland, M

    2017-06-01

    Fundoplication surgery is a commonly performed procedure for gastro-esophageal reflux disease or hiatal hernia repair. Up to 10% of patients develop persistent postoperative dysphagia after surgery. Data on the effectiveness of pneumatic dilation for treatment are limited. The aim of this study was to evaluate clinical outcomes and identify clinical factors associated with successful response to pneumatic dilation among patients with persistent postfundoplication dysphagia (PPFD). We retrospectively evaluated patients who had undergone pneumatic dilation for PPFD between 1999 and 2016. Patients with dysphagia or achalasia prior to fundoplication were excluded. Demographic information, surgical history, severity of dysphagia, and clinical outcomes were collected. Data pertaining to esophagram, manometry, endoscopy, and pneumatic dilation were also collected. We identified 38 patients (82% female, 95% Caucasian, and median age 59 years) with PPFD who completed pneumatic dilation. The median postfundoplication dysphagia score was 2. Eleven patients had abnormal peristalsis on manometry. Seventeen patients reported response (seven complete) with an average decrease of 1 in their dysphagia score. Fifteen patients underwent reoperation due to PPFD. Hiatal hernia repair was the only factor that predicts a higher response rate to pneumatic dilation. Only one patient in our study developed complication (pneumoperitoneum) from pneumatic dilation. We found that pneumatic dilation to be a safe treatment option for PPFD with moderate efficacy. Patients who developed PPFD after a hiatal hernia repair may gain the greatest benefit after pneumatic dilation. We were not able to identify additional clinical, radiological, endoscopic, or manometric parameters that were predictive of response. © 2017 John Wiley & Sons Ltd.

  17. Pneumatization degree of the anterior clinoid process: a new classification.

    PubMed

    Abuzayed, Bashar; Tanriover, Necmettin; Biceroglu, Huseyin; Yuksel, Odhan; Tanriover, Ozlem; Albayram, Sait; Akar, Ziya

    2010-07-01

    The objective of this study is to determine the incidence and degree of anterior clinoid process pneumatization, in addition highlighting to their clinical significance. Multidetector-row CT scans of the skull base were reviewed in 648 subjects between 2007 and 2008. The presence of pneumatized anterior clinoid process and its degree were studied and documented. These data were statistically analyzed. Pneumatization of the ACP was found in 62 of 648 patients (9.6%) including 32 (51.6%) men and 30 (48.4%) women. The age of these patients ranged from 21 to 82 years (mean, 41 +/- 15.7 years). Pneumatization of the ACP occurred only on the left side in 14 cases (22.6%), only on the right side in 11 cases (17.7%), and bilaterally in 37 patients (59.7%). ACP pneumatization Type I, in which less than 50% of the ACP is pneumatized, was found in 47 of 124 sides (38%), Type II, in which more than 50% but not totally pneumatized ACP, was found in 28 of 124 sides (22.6%), and Type III, in which the ACP is totally pneumatized, was found in 22 of 124 sides (17.7%). The incidence of Type I in the general population was 6.6%, Type II was 3.5%, and Type III was 2.5%. Radiologically recognizing the degree of ACP pneumatization is important in decreasing the incidence of surgical complications during anterior clinoidectomy. Proper intraoperative management can be undertaken with special attention to the new classification.

  18. Evaluation of different rotary devices on bone repair in rabbits.

    PubMed

    Ribeiro Junior, Paulo Domingos; Barleto, Christiane Vespasiano; Ribeiro, Daniel Araki; Matsumoto, Mariza Akemi

    2007-01-01

    In oral surgery, the quality of bone repair may be influenced by several factors that can increase the morbidity of the procedure. The type of equipment used for ostectomy can directly affect bone healing. The aim of this study was to evaluate bone repair of mandible bone defects prepared in rabbits using three different rotary devices. Fifteen New Zealand rabbits were randomly assigned to 3 groups (n=5) according to type of rotary device used to create bone defects: I--pneumatic low-speed rotation engine, II--pneumatic high-speed rotation engine, and III--electric low-speed rotation engine. The anatomic pieces were surgically obtained after 2, 7 and 30 days and submitted to histological and morphometric analysis. The morphometric results were expressed as the total area of bone remodeling matrix using an image analysis system. Increases in the bone remodeling matrix were noticed with time along the course of the experiment. No statistically significant differences (p>0.05) were observed among the groups at the three sacrificing time points considering the total area of bone mineralized matrix, although the histological analysis showed a slightly advanced bone repair in group III compared to the other two groups. The findings of the present study suggest that the type of rotary device used in oral and maxillofacial surgery does not interfere with the bone repair process.

  19. Pneumatic grading applied to sugarcane products

    SciTech Connect

    Roka A., G.A.; Boisan C., M.A.; Frolov, V.F.

    1988-09-10

    There are secondary products from processing sugar cane, consisting of light particles having irregular elongated forms and falling into various size fractions: bagasso up to 5 mm, bagassilo 5-0.3 mm, and meole < 0.3 mm. These contain water, since they are obtained in the early stages of making cane sugar. Much of the bagasso and bagassilo is burned in situ in steam boilers at the sugar plants. Also, the various fractions are used in making paper, wood-straw board, and as ingredients for fodder and fertilizers, in addition to raw material in furfural production. These uses require grading and drying. In pneumatic grading, one uses the outgoing combustion products from the steam boilers at the plants and at the same time provides drying. Experiments were conducted in order to perform design calculations on grading these products.

  20. [Pneumatic tube system for blood products transport].

    PubMed

    Bardiaux, L; Boulanger, E; Leconte des Floris, M-F; Bourcier, V; Cottier, D

    2012-11-01

    Blood product transport from blood bank to the patient care areas of hospitals is a key step in the transfusion process. The pneumatic tube system is now widely used in hospitals. Strict performance specifications must be respected to guarantee blood safety: robustness, easy to use and respect the constraints imposed to blood products. To secure the disposal of blood products ordered to a carrier (delivery step), a security device must be deployed (video camera, barcode reading, fax, chip), allowing in particular to limit the risk of addressing error when sending (in the case of device with several arrival stations) or picked up by the wrong carrier. Copyright © 2012 Elsevier Masson SAS. All rights reserved.

  1. Optimizing pneumatic conveying of biomass materials

    NASA Astrophysics Data System (ADS)

    DiCianni, Matthew Edward Michael

    2011-12-01

    Biomass is a readily available but underutilized energy resource. One of the main challenges is the inability of biomass feed stocks like corn stover or wood chips to flow freely without intermittent jamming. This research integrated an automated pneumatic conveying system to efficiently transport biomass into a biomass reactor. Material was held in a storage container until an end effector attached to a 3-axis controller engaged the material to flow through pneumatic vacuum in the carrier fluid of air. The material was disengaged from the carrier fluid through centripetal forces induced by a cyclone separator. As the air was pulled out of the cyclone, the biomass drops out the bottom due to gravitational forces and fell into a secondary storage hopper. The second storage container was for testing purposes only, where the actual apparatus would use a vertically oriented lock hopper to feed material into the biomass reactor. In the experimental test apparatus, sensors measured the storage hopper weight (mass-flow rate), pressure drop from the blower, and input power consumption of the motor. Parameters that were adjusted during testing include pipe diameter, material type, and motor speed. Testing indicated that decreasing the motor speed below its maximum still allows for conveyance of the material without blockage forming in the piping. The data shows that the power consumption of the system can be reduced based on the size and weight of the material introduced to the conveying pipe. Also, conveying certain materials proved to be problematic with particular duct diameters. Ultimately, an optimal duct diameter that can perform efficiently for a broad range of materials was chosen for the given system. Through these improvements, the energy return on investment will be improved for biomass feed stocks, which is taking a step in the right direction to secure the nation's energy independence.

  2. Microfluidic pressure amplifier circuits and electrostatic gates for pneumatic microsystems

    DOEpatents

    Tice, Joshua D.; Bassett, Thomas A.; Desai, Amit V.; Apblett, Christopher A.; Kenis, Paul J. A.

    2016-09-20

    An electrostatic actuator is provide that can include a fluidic line, a first electrode, and a second electrode such that a gate chamber portion of the fluidic line is sandwiched between the first electrode and the second electrode. The electrostatic actuator can also include a pressure-balancing channel in fluid communication with the gate chamber portion where the first electrode is sandwiched between the pressure-balancing channel and the gate chamber portion. A pneumatic valve system is provided which includes an electrostatic gate and a fluidic channel fluidly separate from a fluidic control line. A pneumatic valve portion of the fluidic control line can be positioned relative to a portion of the fluidic channel such that expansion of the pneumatic valve portion restricts fluid flow through the fluidic channel. Methods of using an electrostatic actuator and a pneumatic valve system are also provided.

  3. Spot-Welding Gun With Adjustable Pneumatic Spring

    NASA Technical Reports Server (NTRS)

    Burley, Richard K.

    1990-01-01

    Proposed spot-welding gun equipped with pneumatic spring, which could be bellows or piston and cylinder, exerts force independent of position along stroke. Applies accurate controlled force to joint welded, without precise positioning at critical position within stroke.

  4. Detail, north end of console and pneumatic tube message port, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Detail, north end of console and pneumatic tube message port, also showing mirror to reflect view of communications switchboard - March Air Force Base, Strategic Air Command, Combat Operations Center, 5220 Riverside Drive, Moreno Valley, Riverside County, CA

  5. Analytical Solution to the Pneumatic Transient Rod System at ACRR

    SciTech Connect

    Fehr, Brandon Michael

    2016-01-08

    The ACRR pulse is pneumatically driven by nitrogen in a system of pipes, valves and hoses up to the connection of the pneumatic system and mechanical linkages of the transient rod (TR). The main components of the TR pneumatic system are the regulator, accumulator, solenoid valve and piston-cylinder assembly. The purpose of this analysis is to analyze the flow of nitrogen through the TR pneumatic system in order to develop a motion profile of the piston during the pulse and be able to predict the pressure distributions inside both the cylinder and accumulators. The predicted pressure distributions will be validated against pressure transducer data, while the motion profile will be compared to proximity switch data. By predicting the motion of the piston, pulse timing will be determined and provided to the engineers/operators for verification. The motion profile will provide an acceleration distribution to be used in Razorback to more accurately predict reactivity insertion into the system.

  6. PNEUMATICALLY CLEANING TOP HALF OF LARGE MOLD IN BOX FLOOR ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    PNEUMATICALLY CLEANING TOP HALF OF LARGE MOLD IN BOX FLOOR AREA TO REMOVE ANY EXCESS OR LOOSE SAND. - Stockham Pipe & Fittings Company, Ductile Iron Foundry, 4000 Tenth Avenue North, Birmingham, Jefferson County, AL

  7. Spot-Welding Gun With Adjustable Pneumatic Spring

    NASA Technical Reports Server (NTRS)

    Burley, Richard K.

    1990-01-01

    Proposed spot-welding gun equipped with pneumatic spring, which could be bellows or piston and cylinder, exerts force independent of position along stroke. Applies accurate controlled force to joint welded, without precise positioning at critical position within stroke.

  8. 23. CORE WORKER OPERATING A COREBLOWER THAT PNEUMATICALLY FILLED CORE ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    23. CORE WORKER OPERATING A CORE-BLOWER THAT PNEUMATICALLY FILLED CORE BOXES WITH RESIGN IMPREGNATED SAND AND CREATED A CORE THAT THEN REQUIRED BAKING, CA. 1950. - Stockham Pipe & Fittings Company, 4000 Tenth Avenue North, Birmingham, Jefferson County, AL

  9. TOPICAL REVIEW: Pneumatic and hydraulic microactuators: a review

    NASA Astrophysics Data System (ADS)

    De Volder, Michaël; Reynaerts, Dominiek

    2010-04-01

    The development of MEMS actuators is rapidly evolving and continuously new progress in terms of efficiency, power and force output is reported. Pneumatic and hydraulic are an interesting class of microactuators that are easily overlooked. Despite the 20 years of research, and hundreds of publications on this topic, these actuators are only popular in microfluidic systems. In other MEMS applications, pneumatic and hydraulic actuators are rare in comparison with electrostatic, thermal or piezo-electric actuators. However, several studies have shown that hydraulic and pneumatic actuators deliver among the highest force and power densities at microscale. It is believed that this asset is particularly important in modern industrial and medical microsystems, and therefore, pneumatic and hydraulic actuators could start playing an increasingly important role. This paper shows an in-depth overview of the developments in this field ranging from the classic inflatable membrane actuators to more complex piston-cylinder and drag-based microdevices.

  10. 2. PLENUM WALL, SHOWING PNEUMATIC TUBES. Hot Springs National ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    2. PLENUM WALL, SHOWING PNEUMATIC TUBES. - Hot Springs National Park, Bathhouse Row, Lamar Bathhouse: Mechanical & Piping Systems, State Highway 7, 1 mile north of U.S. Highway 70, Hot Springs, Garland County, AR

  11. Inline evenflow material distributor for pneumatic material feed systems

    DOEpatents

    Thiry, Michael J.

    2007-02-20

    An apparatus for reducing clogs in a pneumatic material feed line, such as employed in abrasive waterjet machining systems, by providing an evenflow feed of material therethrough. The apparatus preferably includes a hollow housing defining a housing volume and having an inlet capable of connecting to an upstream portion of the pneumatic material feed line, an outlet capable of connecting to a downstream portion of the pneumatic material feed line, and an air vent located between the inlet and outlet for venting excess air pressure out from the housing volume. A diverter, i.e. an impingement object, is located at the inlet and in a path of incoming material from the upstream portion of the pneumatic material feed line, to break up clumps of ambient moisture-ridden material impinging on the diverter. And one or more filter screens is also preferably located in the housing volume to further break up clumps and provide filtering.

  12. Common procedures in rabbits.

    PubMed

    Graham, Jennifer

    2006-05-01

    Rabbits are popular companion animals that present to veterinary clinics for routine and emergency care. Clinics equipped for treat-ing dogs and cats may be easily adapted to accommodate rabbits. This article reviews common procedures performed by the clinician specific to rabbits. Topics include handling and restraint, triage and patient assessment, sample collection, and supportive care techniques. Miscellaneous procedures, including anesthetic delivery, nasolacrimal duct flushing, and ear cleaning, are also discussed.

  13. Effects of low-power laser irradiation on the mitosis rate of the corneal epithelium

    NASA Astrophysics Data System (ADS)

    Chen, Varda; Landshman, Nahum; Belkin, Michael

    1995-05-01

    The effect of repeated low power He-Ne laser on rabbit's corneal epithelium was studied after 3 daily sessions. Under certain irradiation parameters, low power He-Ne laser irradiation was found to change the mitotic rate in the basal layer of intact corneal epithelium. Three daily irradiations for 3 or 10 minutes increased the mitotic index while 30 minutes irradiations decreased it.

  14. INFECTIOUS PAPILLOMATOSIS OF RABBITS

    PubMed Central

    Shope, Richard E.; Hurst, E. Weston

    1933-01-01

    A papilloma has been observed in wild cottontail rabbits and has been found to be transmissible to both wild and domestic rabbits. The clinical and pathological pictures of the condition have been described. It has been found that the causative agent is readily filtrable through Berkefeld but not regularly through Seitz filters, that it stores well in glycerol, that it is still active after heating to 67°C. for 30 minutes, but not after heating to 70°C., and that it exhibits a marked tropism for cutaneous epithelium. The activities and properties of the papilloma-producing agent warrant its classification as a filtrable virus. Rabbits carrying experimentally produced papillomata are partially or completely immune to reinfection and, furthermore, their sera partially or completely neutralize the causative virus. The disease is transmissible in series through wild rabbits and virus of wild rabbit origin is readily transmissible to domestic rabbits, producing in this species papillomata identical in appearance with those found in wild rabbits. However, the condition is not transmissible in series through domestic rabbits. The possible significance of this observation has been discussed. The virus of infectious papillomatosis is not related immunologically to either the virus of infectious fibroma or to that of infectious myxoma of rabbits. PMID:19870219

  15. Pneumatic Regolith Transfer Systems for In Situ Resource Utilization

    NASA Technical Reports Server (NTRS)

    Mueller, R. P.; Townsend, I. I.; Mantovani, J. G.; Zacny, Kris A.; Craft, Jack

    2010-01-01

    This slide presentation reviews the testing of a pneumatic system for transfering regolith, to be used for In Situ Resource Utilization (ISRU). Using both the simulated microgravity of parabolic flight and ground testing, the tests demonstrated that lunar regolith can be conveyed pneumatically into a simulated ISRU oxygen production plant reactor. The ground testing also demonstrated that the regolith can be expelled from the ISRU reactor for disposal or for other resource processing.

  16. Intracranial pressure monitoring system with pneumatic capsule sensor

    NASA Astrophysics Data System (ADS)

    Juniewicz, Henryk M.; Werszko, Miroslaw

    1995-06-01

    In the paper, a computer system for measurement, visualization and analysis of intracranial pressure (ICP), medium arterial pressure and cerebral perfusion pressure in one, two, three or four patients simultaneously has been presented. A structure of pneumatic compensatory sensor for intracranial pressure, and a stand for static properties of the sensors testing has been discussed. Conclusions resulting from the period of using the monitoring system with ICP pneumatic sensors have been formulated.

  17. A high resolution pneumatic stepping actuator for harsh reactor environments

    SciTech Connect

    Tippetts, T.B.; Evans, P.S.; Riffle, G.K. )

    1993-01-20

    A reactivity control actuator for a high-power density nuclear propulsion reactor must be installed in close proximity to the reactor core. The energy input from radiation to the actuator structure could exceed hundreds of W/cc unless low-cross section, low-absorptivity materials are chosen. Also, for post-test handling and subsequent storage, materials should not be used that are activated into long half-life isotopes. Pneumatic actuators can be constructed from various reactor-compatible materials, but conventional pneumatic piston actuators generally lack the stiffness required for high resolution reactivity control unless electrical position sensors and compensated electronic control systems are used. To overcome these limitations, a pneumatic actuator is under development that positions an output shaft in response to a series of pneumatic pulses, comprising a pneumatic analog of an electrical stepping motor. The pneumatic pulses are generated remotely, beyond the strong radiation environment, and transmitted to the actuator through tubing. The mechanically simple actuator uses a nutating gear harmonic drive to convert motion of small pistons directly to high-resolution angular motion of the output shaft. The digital nature of this actuator is suitable for various reactor control algorithms but is especially compatible with the three bean salad algorithm discussed by Ball [ital et] [ital al]. (1991).

  18. A high resolution pneumatic stepping actuator for harsh reactor environments

    NASA Astrophysics Data System (ADS)

    Tippetts, Thomas B.; Evans, Paul S.; Riffle, George K.

    1993-01-01

    A reactivity control actuator for a high-power density nuclear propulsion reactor must be installed in close proximity to the reactor core. The energy input from radiation to the actuator structure could exceed hundreds of W/cc unless low-cross section, low-absorptivity materials are chosen. Also, for post-test handling and subsequent storage, materials should not be used that are activated into long half-life isotopes. Pneumatic actuators can be constructed from various reactor-compatible materials, but conventional pneumatic piston actuators generally lack the stiffness required for high resolution reactivity control unless electrical position sensors and compensated electronic control systems are used. To overcome these limitations, a pneumatic actuator is under development that positions an output shaft in response to a series of pneumatic pulses, comprising a pneumatic analog of an electrical stepping motor. The pneumatic pulses are generated remotely, beyond the strong radiation environment, and transmitted to the actuator through tubing. The mechanically simple actuator uses a nutating gear harmonic drive to convert motion of small pistons directly to high-resolution angular motion of the output shaft. The digital nature of this actuator is suitable for various reactor control algorithms but is especially compatible with the three bean salad algorithm discussed by Ball et al. (1991).

  19. Development of pneumatic actuator with low-wave reflection characteristics

    NASA Astrophysics Data System (ADS)

    Chang, H.; Tsung, T. T.; Jwo, C. S.; Chiang, J. C.

    2010-08-01

    This study aims at the development of a less reflective electromagnetic pneumatic actuator often used in the anechoic chamber. Because a pneumatic actuator on the market is not appropriate for use in such a chamber and a metallic one has high dielectric constant which generates reflective electromagnetic waves to influence test parameters in the chamber. The newly developed pneumatic actuator is made from low dielectric constant plastics with less reflective of electromagnetic. A turbine-type air motor is used to develop the pneumatic actuator and a employ Prony tester is used to run the brake horsepower test for the performance test of pneumatic actuator. Test results indicate that the pneumatic actuator in the minimal starting flow is 17 l/min, and it generates a brake horsepower of 48 mW; in the maximum flow is 26 l/min, it generates a brake horsepower of 108 mW. Therefore, it works with a torque between 0.24 N-m and 0.55 N-m, and such a torque will be sufficient to drive the target button.

  20. A New Type of Motor: Pneumatic Step Motor

    PubMed Central

    Stoianovici, Dan; Patriciu, Alexandru; Petrisor, Doru; Mazilu, Dumitru; Kavoussi, Louis

    2011-01-01

    This paper presents a new type of pneumatic motor, a pneumatic step motor (PneuStep). Directional rotary motion of discrete displacement is achieved by sequentially pressurizing the three ports of the motor. Pulsed pressure waves are generated by a remote pneumatic distributor. The motor assembly includes a motor, gearhead, and incremental position encoder in a compact, central bore construction. A special electronic driver is used to control the new motor with electric stepper indexers and standard motion control cards. The motor accepts open-loop step operation as well as closed-loop control with position feedback from the enclosed sensor. A special control feature is implemented to adapt classic control algorithms to the new motor, and is experimentally validated. The speed performance of the motor degrades with the length of the pneumatic hoses between the distributor and motor. Experimental results are presented to reveal this behavior and set the expectation level. Nevertheless, the stepper achieves easily controllable precise motion unlike other pneumatic motors. The motor was designed to be compatible with magnetic resonance medical imaging equipment, for actuating an image-guided intervention robot, for medical applications. For this reason, the motors were entirely made of nonmagnetic and dielectric materials such as plastics, ceramics, and rubbers. Encoding was performed with fiber optics, so that the motors are electricity free, exclusively using pressure and light. PneuStep is readily applicable to other pneumatic or hydraulic precision-motion applications. PMID:21528106

  1. The methodology for the existing complex pneumatic systems efficiency increase with the use of mathematical modeling

    NASA Astrophysics Data System (ADS)

    Danilishin, A. M.; Kartashov, S. V.; Kozhukhov, Y. V.; Kozin, E. G.

    2017-08-01

    The method for the existing complex pneumatic systems efficiency increase has been developed, including the survey steps, mathematical technological process modeling, optimizing the pneumatic system configuration, its operation modes, selection of optimal compressor units and additional equipment. Practical application of the methodology is considered by the example of the existing pneumatic systems underground depot reconstruction. The first stage of the methodology is the survey of acting pneumatic system. The second stage of technique is multivariable mathematical modeling of the pneumatic system operation. The developed methodology is applicable to complex pneumatic systems.

  2. Autoantibody Production in Rabbits

    PubMed Central

    Asherson, G. L.; Rose, M. Elaine

    1963-01-01

    The finding that the serum of apparently healthy rabbits fixed complement with rabbit liver and kidney has been confirmed. Experimental infection of rabbits with Eimeria stiedae, the cause of hepatic coccidiosis, led to a rise in the titre of serum complement-fixing factors. The rise was statistically significant 14, 21 and 28 days after infection. The factors were regarded as antibodies because they behaved as macroglobulins on diethylaminoethyl—cellulose chromatography and sucrose gradient centrifugation, and as autoantibodies because they fixed complement with the kidney of the rabbits in which they occurred. The antibody reacted with widely distributed antigen(s) with high activity in brain and low activity in skeletal muscle. The possibility that coccidial infection may be responsible for the natural autoantibody of rabbits is discussed. PMID:13965167

  3. Photodynamic therapy for implanted VX2 tumor in rabbit brains

    NASA Astrophysics Data System (ADS)

    Li, Fei; Feng, Hua; Lin, Jiangkai; Zhu, Gang; Chen, Zhi; Li, Cong-yan

    2005-07-01

    To evaluate the therapeutic effect and the safety of single photodynamic therapy (PDT) with hematoporphyrin derivative produced in China, 60 New Zealand adult rabbits with VX2 tumor implanted into the brain were divided randomly into non-PDT-group and PDT-group. 36 rabbits of the PDT-group were performed photodynamic therapy. The survival time, neurological deteriorations, intracranial pressure (ICP), histology, pathology, tumor volume and brain water content were measured. Other 12 rabbits were received hematoporphyrin derivative and light irradiation of the normal brain. The ICP, histology, pathology, and brain water content were measured. The result indicated that Simple PDT may elongate the average survival time of the rabbits with VX2 tumors significantly; kill tumor cells; cause transient brain edema and increase ICP, but it is safe to be used in treating brain tumor.

  4. Use of pneumatic lithotripsy for managing difficult CBD calculi.

    PubMed

    Farooq Qadri, Syed Javid; Khan, Muneer; Khan, Naveed

    2011-01-01

    About 7-12% of patients who harbor gallbladder calculi concomitant common bile duct (CBD) calculi are present. The treatment of gallbladder calculi has standardized in the form of laparoscopic cholecystectomy but management of CBD calculi is still evolving. Endoscopic removal of CBD calculi <2 cm in diameter is successful in 90-100% of cases but patients harboring stones >2 cm in diameter high failure rates can be seen. Traditionally, laparoscopically one can achieve success rate comparable to endoscopic surgery but large and impacted calculi may cause failures. If one uses pneumatic lithotripsy during laparoscopic management of CBD calculi one can achieve 100% stone clearance irrespective of size, degree of hardness and impaction. This study evaluates the feasibility of using pneumatic lithotripsy for CBD calculi. To our knowledge this is the 1st reported series of using pneumatic lithotripsy for CBD calculi. From June 2002 to June 2010 96 laparoscopic CBD explorations (LCBDE) were done for CBD calculi. Patients having choledocholithiasis with CBD diameter of >10 mm were taken for LCBDE while in patients with CBD diameter of <10 mm were referred for endoscopic clearance. Additionally ERCP failure cases were also subjected to LCBDE. Rigid nephroscope was used for LCBDE and usually calculi were removed by forceps only. In patients having large, hard &/or impacted calculi pneumatic lithotripsy were used for fragmentation. Out of the 96 patients in 12 (12.5%) cases pneumatic lithotripsy was used for stone fragmentation. Out of these 12 cases 5 (41.6%) were ERCP failure cases. At a mean hospital stay of 2.5 days 100% stone clearance was achieved in all cases with no perioperative complication. The present study shows how successfully pneumatic lithotripsy can be used to fragment large, hard &/or impacted CBD calculi. Pneumatic lithotripsy being user friendly easily available can reliably fragment CBD calculi in one session. Copyright © 2010 Surgical Associates

  5. Design of flat pneumatic artificial muscles

    NASA Astrophysics Data System (ADS)

    Wirekoh, Jackson; Park, Yong-Lae

    2017-03-01

    Pneumatic artificial muscles (PAMs) have gained wide use in the field of robotics due to their ability to generate linear forces and motions with a simple mechanism, while remaining lightweight and compact. However, PAMs are limited by their traditional cylindrical form factors, which must increase radially to improve contraction force generation. Additionally, this form factor results in overly complicated fabrication processes when embedded fibers and sensor elements are required to provide efficient actuation and control of the PAMs while minimizing the bulkiness of the overall robotic system. In order to overcome these limitations, a flat two-dimensional PAM capable of being fabricated using a simple layered manufacturing process was created. Furthermore, a theoretical model was developed using Von Karman’s formulation for large deformations and the energy methods. Experimental characterizations of two different types of PAMs, a single-cell unit and a multi-cell unit, were performed to measure the maximum contraction lengths and forces at input pressures ranging from 0 to 150 kPa. Experimental data were then used to verify the fidelity of the theoretical model.

  6. Dynamic contraction behaviour of pneumatic artificial muscle

    NASA Astrophysics Data System (ADS)

    Doumit, Marc D.; Pardoel, Scott

    2017-07-01

    The development of a dynamic model for the Pneumatic Artificial Muscle (PAM) is an imperative undertaking for understanding and analyzing the behaviour of the PAM as a function of time. This paper proposes a Newtonian based dynamic PAM model that includes the modeling of the muscle geometry, force, inertia, fluid dynamic, static and dynamic friction, heat transfer and valve flow while ignoring the effect of bladder elasticity. This modeling contribution allows the designer to predict, analyze and optimize PAM performance prior to its development. Thus advancing successful implementations of PAM based powered exoskeletons and medical systems. To date, most muscle dynamic properties are determined experimentally, furthermore, no analytical models that can accurately predict the muscle's dynamic behaviour are found in the literature. Most developed analytical models adequately predict the muscle force in static cases but neglect the behaviour of the system in the transient response. This could be attributed to the highly challenging task of deriving such a dynamic model given the number of system elements that need to be identified and the system's highly non-linear properties. The proposed dynamic model in this paper is successfully simulated through MATLAB programing and validated the pressure, contraction distance and muscle temperature with experimental testing that is conducted with in-house built prototype PAM's.

  7. Expanded criteria for pneumatic retinopexy and potential cost savings.

    PubMed

    Goldman, Darin R; Shah, Chirag P; Heier, Jeffrey S

    2014-01-01

    To provide insight into the preoperative factors that affect outcome after pneumatic retinopexy (PR) for treatment of primary rhegmatogenous retinal detachment repair. Additionally, we sought to analyze the cost of rhegmatogenous retinal detachment repair in the United States to determine potential cost savings with pneumatic retinopexy. Single-center, retrospective, observational consecutive case series and third party payer-perspective comparative cost analysis. We included 141 eyes undergoing pneumatic retinopexy for the treatment of primary rhegmatogenous retinal detachment. Preoperative characteristics, anatomic outcomes, and best-available visual acuity were collected. Anatomic and visual outcomes were analyzed based on the presence of selected preoperative factors. The primary cohort was divided into 2 groups based on preoperative characteristics: (1) traditional pneumatic retinopexy and (2) nontraditional pneumatic retinopexy. Comparative cost analyses were performed between pneumatic retinopexy, scleral buckling, and vitrectomy. Anatomic and visual outcomes at 6 months. Overall anatomic success was 78.7% and visual acuity improved significantly (logarithm of the minimum angle of resolution [logMAR] 0.48-0.25; P <0.005). A 97.6% final anatomic success rate was achieved. Anatomic outcomes were similar between traditional versus nontraditional (84.1% vs 74.4%; P = 0.16), phakic versus pseudophakic (79.1% vs 78.0%; P = 0.88), and macula-on versus macula-off (77.9% vs 81.1%; P = 0.68) groups. Anatomic failure was predicted by the presence of an inferior retinal break (P <0.005) or visible vitreous traction on a retinal break (P = 0.04). Visual outcomes were similar between each of the traditional versus nontraditional (logMAR 0.21 vs 0.27; P >0.05) and phakic versus pseudophakic groups (logMAR 0.23 vs 0.28; P >0.05). Visual outcomes were better in macula-on detachments compared with those in which the macula was detached (logMAR 0.18 vs 0.42; P <0

  8. Pneumatic dilation versus laparoscopic Heller's myotomy for idiopathic achalasia.

    PubMed

    Boeckxstaens, Guy E; Annese, Vito; des Varannes, Stanislas Bruley; Chaussade, Stanislas; Costantini, Mario; Cuttitta, Antonello; Elizalde, J Ignasi; Fumagalli, Uberto; Gaudric, Marianne; Rohof, Wout O; Smout, André J; Tack, Jan; Zwinderman, Aeilko H; Zaninotto, Giovanni; Busch, Olivier R

    2011-05-12

    Many experts consider laparoscopic Heller's myotomy (LHM) to be superior to pneumatic dilation for the treatment of achalasia, and LHM is increasingly considered to be the treatment of choice for this disorder. We randomly assigned patients with newly diagnosed achalasia to pneumatic dilation or LHM with Dor's fundoplication. Symptoms, including weight loss, dysphagia, retrosternal pain, and regurgitation, were assessed with the use of the Eckardt score (which ranges from 0 to 12, with higher scores indicating more pronounced symptoms). The primary outcome was therapeutic success (a drop in the Eckardt score to ≤3) at the yearly follow-up assessment. The secondary outcomes included the need for retreatment, pressure at the lower esophageal sphincter, esophageal emptying on a timed barium esophagogram, quality of life, and the rate of complications. A total of 201 patients were randomly assigned to pneumatic dilation (95 patients) or LHM (106). The mean follow-up time was 43 months (95% confidence interval [CI], 40 to 47). In an intention-to-treat analysis, there was no significant difference between the two groups in the primary outcome; the rate of therapeutic success with pneumatic dilation was 90% after 1 year of follow-up and 86% after 2 years, as compared with a rate with LHM of 93% after 1 year and 90% after 2 years (P=0.46). After 2 years of follow-up, there was no significant between-group difference in the pressure at the lower esophageal sphincter (LHM, 10 mm Hg [95% CI, 8.7 to 12]; pneumatic dilation, 12 mm Hg [95% CI, 9.7 to 14]; P=0.27); esophageal emptying, as assessed by the height of barium-contrast column (LHM, 1.9 cm [95% CI, 0 to 6.8]; pneumatic dilation, 3.7 cm [95% CI, 0 to 8.8]; P=0.21); or quality of life. Similar results were obtained in the per-protocol analysis. Perforation of the esophagus occurred in 4% of the patients during pneumatic dilation, whereas mucosal tears occurred in 12% during LHM. Abnormal exposure to esophageal acid was

  9. Mechanical implications of pneumatic neck vertebrae in sauropod dinosaurs.

    PubMed

    Schwarz-Wings, Daniela; Meyer, Christian A; Frey, Eberhard; Manz-Steiner, Hans-Rudolf; Schumacher, Ralf

    2010-01-07

    The pre-sacral vertebrae of most sauropod dinosaurs were surrounded by interconnected, air-filled diverticula, penetrating into the bones and creating an intricate internal cavity system within the vertebrae. Computational finite-element models of two sauropod cervical vertebrae now demonstrate the mechanical reason for vertebral pneumaticity. The analyses show that the structure of the cervical vertebrae leads to an even distribution of all occurring stress fields along the vertebrae, concentrated mainly on their external surface and the vertebral laminae. The regions between vertebral laminae and the interior part of the vertebral body including thin bony struts and septa are mostly unloaded and pneumatic structures are positioned in these regions of minimal stress. The morphology of sauropod cervical vertebrae was influenced by strongly segmented axial neck muscles, which require only small attachment areas on each vertebra, and pneumatic epithelia that are able to resorb bone that is not mechanically loaded. The interaction of these soft tissues with the bony tissue of the vertebrae produced lightweight, air-filled vertebrae in which most stresses were borne by the external cortical bone. Cervical pneumaticity was therefore an important prerequisite for neck enlargement in sauropods. Thus, we expect that vertebral pneumaticity in other parts of the body to have a similar role in enabling gigantism.

  10. Mechanical implications of pneumatic neck vertebrae in sauropod dinosaurs

    PubMed Central

    Schwarz-Wings, Daniela; Meyer, Christian A.; Frey, Eberhard; Manz-Steiner, Hans-Rudolf; Schumacher, Ralf

    2010-01-01

    The pre-sacral vertebrae of most sauropod dinosaurs were surrounded by interconnected, air-filled diverticula, penetrating into the bones and creating an intricate internal cavity system within the vertebrae. Computational finite-element models of two sauropod cervical vertebrae now demonstrate the mechanical reason for vertebral pneumaticity. The analyses show that the structure of the cervical vertebrae leads to an even distribution of all occurring stress fields along the vertebrae, concentrated mainly on their external surface and the vertebral laminae. The regions between vertebral laminae and the interior part of the vertebral body including thin bony struts and septa are mostly unloaded and pneumatic structures are positioned in these regions of minimal stress. The morphology of sauropod cervical vertebrae was influenced by strongly segmented axial neck muscles, which require only small attachment areas on each vertebra, and pneumatic epithelia that are able to resorb bone that is not mechanically loaded. The interaction of these soft tissues with the bony tissue of the vertebrae produced lightweight, air-filled vertebrae in which most stresses were borne by the external cortical bone. Cervical pneumaticity was therefore an important prerequisite for neck enlargement in sauropods. Thus, we expect that vertebral pneumaticity in other parts of the body to have a similar role in enabling gigantism. PMID:19801376

  11. [Pneumatic tube system for transport of laboratory samples: preanalytical aspects].

    PubMed

    Tóth, Judit; Lenkey, Ágota; V Oláh, Anna; Köteles, Julianna; Kissné Sziráki, Valéria; Kerényi, Adrienne; Kappelmayer, János

    2014-07-13

    A considerable proportion of laboratory errors occurs in the preanalytical phase. The aims of the authors were to study preanalytical errors in routine and emergency laboratory diagnostics in a regional clinical laboratory and evaluate the effect of the pneumatic tube system on turnaround time and laboratory results. The ratio of preanalytical errors and reasons of test rejection were analysed. In addition, the effects of pneumatic tube and manual transport on the occurrence of hemolysis and platelet activation were compared. Using the pneumatic tube transport system, preanalytical error was below 1%. The main causes of test rejection were haemolysis in case of serum samples, and clot formation and citrate excess in anticoagulated samples. The pneumatic tube transport resulted in significantly faster sample transport, more equalized sample arrival and processing, hence the turnaround time became shorter both for routine and emergency tests. Autovalidation and proper control of preanalytical errors are essential for rapid and reliable laboratory service supported by the pneumatic tube system for sample transport.

  12. Hemolysis associated with pneumatic tube system transport for blood samples

    PubMed Central

    Kara, Hasan; Bayir, Aysegul; Ak, Ahmet; Degirmenci, Selim; Akinci, Murat; Agacayak, Ahmet; Marcil, Emine; Azap, Melih

    2014-01-01

    Objective: The frequency of hemolysis of blood samples may be increased by transport in a pneumatic tube system. The purpose of this study was to evaluate the effect of pneumatic tube system transport on hemolysis of blood samples. Methods: Blood samples were transported from the emergency department to the hospital laboratory manually by hospital staff (49 patients) or with a pneumatic tube system (53 patients). The hemolysis index and serum chemistry studies were performed on the blood samples and compared between the different methods of transport. Results: The blood samples that were transported by the pneumatic tube system had a greater frequency of hemolysis and greater mean serum potassium and median creatinine, aspartate aminotransferase, and lactate dehydrogenase levels than samples transported manually. Conclusion: Blood samples transported from the emergency department to the hospital laboratory by a pneumatic tube system may have a greater frequency of hemolysis than samples transported manually. This may necessitate repeat phlebotomy and cause a delay in completing the laboratory analysis. PMID:24639830

  13. Pneumatic distortion compensation for aircraft surface pressure sensing devices

    NASA Technical Reports Server (NTRS)

    Whitmore, Stephen A.; Leondes, Cornelius T.

    1991-01-01

    In this paper a technique of compensating for pneumatic distortion in aircraft surface pressure sensing devices is developed. The compensation allows conventional pressure sensing technology to obtain improved unsteady pressure measurements. Pressure distortion caused by frictional attenuation and pneumatic resonance within the sensing system makes obtaining unsteady pressure measurements by conventional sensors difficult. Typically, most of the distortion occurs within the pneumatic tubing used to transmit pressure impulses from the surface of the aircraft to the measurement transducer. This paper develops a second-order distortion model that accurately describes the behavior of the primary wave harmonic of the pneumatic tubing. The model is expressed in state-variable form and is coupled with standard results from minimum-variance estimation theory to develop an algorithm to compensate for the effects of pneumatic distortion. Both postflight and real-time algorithms are developed and evaluated using simulated and flight data. Covariance selection and filter-tuning examples are presented. Results presented verify that, given appropriate covariance magnitudes, the algorithms accurately reconstruct surface pressure values from remotely sensed pressure measurements.

  14. Pneumatic tourniquet for surgical procedures of hemodialysis vascular access.

    PubMed

    Wang, Shouwen

    2015-01-01

    Pneumatic tourniquet has been frequently utilized in various surgical specialties to facilitate surgical procedures on the extremities. However, its use for surgical procedures of hemodialysis access has been limited to some surgeons in the United States and often confined to the hospital settings under general anesthesia or regional nerve block. We have successfully employed a pneumatic tourniquet system for surgical procedures of hemodialysis access under conscious sedation and local anesthesia in an outpatient setting. Because prolonged tourniquet inflation is associated with ischemic pain and other potential complications, we have limited the continuous inflation time to <30 minutes. Our recent data from 550 surgical procedures of hemodialysis access have emphasized that pneumatic tourniquet use is well tolerated under conscious sedation and not associated with significant adverse events. These and other reported data suggest that pneumatic tourniquet can reduce procedure time, minimize required dissection, reduce vascular trauma by eliminating vascular clamps and potentially improve the outcomes of surgical procedures of hemodialysis access. These advantages may be translated into cost savings for hemodialysis access care. This review discusses practical issues of pneumatic tourniquet use and its applications in surgical procedures of hemodialysis access. © 2014 Wiley Periodicals, Inc.

  15. Pneumatic distortion compensation for aircraft surface pressure sensing devices

    NASA Technical Reports Server (NTRS)

    Whitmore, Stephen A.; Leondes, Cornelius T.

    1991-01-01

    In this paper a technique of compensating for pneumatic distortion in aircraft surface pressure sensing devices is developed. The compensation allows conventional pressure sensing technology to obtain improved unsteady pressure measurements. Pressure distortion caused by frictional attenuation and pneumatic resonance within the sensing system makes obtaining unsteady pressure measurements by conventional sensors difficult. Typically, most of the distortion occurs within the pneumatic tubing used to transmit pressure impulses from the surface of the aircraft to the measurement transducer. This paper develops a second-order distortion model that accurately describes the behavior of the primary wave harmonic of the pneumatic tubing. The model is expressed in state-variable form and is coupled with standard results from minimum-variance estimation theory to develop an algorithm to compensate for the effects of pneumatic distortion. Both postflight and real-time algorithms are developed and evaluated using simulated and flight data. Covariance selection and filter-tuning examples are presented. Results presented verify that, given appropriate covariance magnitudes, the algorithms accurately reconstruct surface pressure values from remotely sensed pressure measurements.

  16. Hepatitis E Virus in Farmed Rabbits, Wild Rabbits and Petting Farm Rabbits in the Netherlands.

    PubMed

    Burt, Sara A; Veltman, Jorg; Hakze-van der Honing, Renate; Schmitt, Heike; van der Poel, Wim H M

    2016-09-01

    Rabbits have been suggested as a zoonotic source of Hepatitis E virus. Phylogenetic analysis of HEV isolates from farmed, wild and pet rabbits in the Netherlands (23, 0, and 60 % respectively) showed them to be grouped amongst published rabbit HEV sequences and distinct from most human isolates. Dutch rabbits are unlikely to be a zoonotic source.

  17. SERUM SICKNESS IN RABBITS

    PubMed Central

    Fleisher, Mover S.; Jones, Lloyd

    1931-01-01

    1. The injection of a single large dose of normal horse serum into rabbits results in the appearance 3 to 8 days later of erythematous and edematous reactions on the ears in 68.9 per cent of the animals. 2. The injections may be given by any of several routes and reactions appear when the site of injection is definitely distant from the ears. 3. Injections of various antisera into rabbits cause the appearance of similar reactions. 4. These reactions can be considered as manifestations of serum sickness in rabbits. PMID:19869943

  18. Rabbit orthopedic surgery.

    PubMed

    Rich, Gregory A

    2002-01-01

    Orthopedic surgery in rabbits poses several unique parameters for the veterinary surgeon. It is imperative for the veterinarian to be knowledgeable about the anatomic features of the surgical repair site and to become familiar with a rabbit's pain and discomfort often associated with orthopedic injuries. Handling the perioperative and postoperative pain and potential GI disturbances are crucial for a successful outcome of the surgical case. This article is designed to help the veterinary surgeon prepare for the orthopedic surgical procedure and the peripheral physiologic needs of the rabbit from presentation through recovery.

  19. Experimental investigations in hamsters and rabbits with DNA extracted from human uterine tumors.

    PubMed

    Nastac, E; Athanasiu, P; Predescu, E; Stoian, M; Hozoc, M; Perju, A

    1980-01-01

    Experimental inoculation of a DNA preparation extracted from a fragment of non-irradiated human uterine cervix carcinoma was followed by the appearance of neoplasia in four hamsters and of lymphosarcoma in one rabbit. Similar DNA preparations obtained from three cases of irradiated human uterine cervix carcinoma and from a human uterine fibroma proved to have no biological activity.

  20. 46 CFR 56.97-35 - Pneumatic tests (replaces 137.5).

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 2 2010-10-01 2010-10-01 false Pneumatic tests (replaces 137.5). 56.97-35 Section 56.97... SYSTEMS AND APPURTENANCES Pressure Tests § 56.97-35 Pneumatic tests (replaces 137.5). (a) General Requirements. When a pneumatic test is performed, it must be conducted in accordance with the requirements of...

  1. 46 CFR 128.240 - Hydraulic or pneumatic power and control-materials and pressure design.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Hydraulic or pneumatic power and control-materials and... Hydraulic or pneumatic power and control—materials and pressure design. (a) Each standard piping component (such as pipe runs, fittings, flanges, and standard valves) for hydraulic or pneumatic power and control...

  2. 14 CFR 23.1416 - Pneumatic de-icer boot system.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Pneumatic de-icer boot system. 23.1416... Safety Equipment § 23.1416 Pneumatic de-icer boot system. If certification with ice protection provisions is desired and a pneumatic de-icer boot system is installed— (a) The system must meet the...

  3. 14 CFR 23.1416 - Pneumatic de-icer boot system.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 14 Aeronautics and Space 1 2014-01-01 2014-01-01 false Pneumatic de-icer boot system. 23.1416... Safety Equipment § 23.1416 Pneumatic de-icer boot system. If certification with ice protection provisions is desired and a pneumatic de-icer boot system is installed— (a) The system must meet...

  4. 14 CFR 23.1416 - Pneumatic de-icer boot system.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Pneumatic de-icer boot system. 23.1416... Safety Equipment § 23.1416 Pneumatic de-icer boot system. If certification with ice protection provisions is desired and a pneumatic de-icer boot system is installed— (a) The system must meet...

  5. 14 CFR 23.1416 - Pneumatic de-icer boot system.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 14 Aeronautics and Space 1 2012-01-01 2012-01-01 false Pneumatic de-icer boot system. 23.1416... Safety Equipment § 23.1416 Pneumatic de-icer boot system. If certification with ice protection provisions is desired and a pneumatic de-icer boot system is installed— (a) The system must meet...

  6. 14 CFR 23.1416 - Pneumatic de-icer boot system.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 14 Aeronautics and Space 1 2013-01-01 2013-01-01 false Pneumatic de-icer boot system. 23.1416... Safety Equipment § 23.1416 Pneumatic de-icer boot system. If certification with ice protection provisions is desired and a pneumatic de-icer boot system is installed— (a) The system must meet...

  7. 46 CFR 108.409 - Location and spacing of tubing in pneumatic fire detection system.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... detection system. 108.409 Section 108.409 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED... and spacing of tubing in pneumatic fire detection system. (a) All tubing in a pneumatic fire detection... exposed in the space. (c) A pneumatic fire detection system must be set to activate after approximately a...

  8. 46 CFR 108.409 - Location and spacing of tubing in pneumatic fire detection system.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... detection system. 108.409 Section 108.409 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED... and spacing of tubing in pneumatic fire detection system. (a) All tubing in a pneumatic fire detection... exposed in the space. (c) A pneumatic fire detection system must be set to activate after approximately a...

  9. 46 CFR 108.409 - Location and spacing of tubing in pneumatic fire detection system.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... detection system. 108.409 Section 108.409 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED... and spacing of tubing in pneumatic fire detection system. (a) All tubing in a pneumatic fire detection... exposed in the space. (c) A pneumatic fire detection system must be set to activate after approximately a...

  10. 46 CFR 108.409 - Location and spacing of tubing in pneumatic fire detection system.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... detection system. 108.409 Section 108.409 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED... and spacing of tubing in pneumatic fire detection system. (a) All tubing in a pneumatic fire detection... exposed in the space. (c) A pneumatic fire detection system must be set to activate after approximately a...

  11. 49 CFR 571.117 - Standard No. 117; Retreaded pneumatic tires.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 6 2012-10-01 2012-10-01 false Standard No. 117; Retreaded pneumatic tires. 571... Federal Motor Vehicle Safety Standards § 571.117 Standard No. 117; Retreaded pneumatic tires. S1. Scope... passenger car tires. S2. Purpose. The purpose of this standard is to require retreaded pneumatic passenger...

  12. 49 CFR 571.117 - Standard No. 117; Retreaded pneumatic tires.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 6 2014-10-01 2014-10-01 false Standard No. 117; Retreaded pneumatic tires. 571... Federal Motor Vehicle Safety Standards § 571.117 Standard No. 117; Retreaded pneumatic tires. S1. Scope... passenger car tires. S2. Purpose. The purpose of this standard is to require retreaded pneumatic passenger...

  13. 46 CFR 128.240 - Hydraulic or pneumatic power and control-materials and pressure design.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 4 2014-10-01 2014-10-01 false Hydraulic or pneumatic power and control-materials and... Hydraulic or pneumatic power and control—materials and pressure design. (a) Each standard piping component (such as pipe runs, fittings, flanges, and standard valves) for hydraulic or pneumatic power and...

  14. 46 CFR 128.240 - Hydraulic or pneumatic power and control-materials and pressure design.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 4 2013-10-01 2013-10-01 false Hydraulic or pneumatic power and control-materials and... Hydraulic or pneumatic power and control—materials and pressure design. (a) Each standard piping component (such as pipe runs, fittings, flanges, and standard valves) for hydraulic or pneumatic power and...

  15. 49 CFR 571.117 - Standard No. 117; Retreaded pneumatic tires.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 6 2013-10-01 2013-10-01 false Standard No. 117; Retreaded pneumatic tires. 571... Federal Motor Vehicle Safety Standards § 571.117 Standard No. 117; Retreaded pneumatic tires. S1. Scope... passenger car tires. S2. Purpose. The purpose of this standard is to require retreaded pneumatic passenger...

  16. An Ankle-Foot Orthosis Powered by Artificial Pneumatic Muscles

    PubMed Central

    Ferris, Daniel P.; Czerniecki, Joseph M.; Hannaford, Blake

    2005-01-01

    We developed a pneumatically powered orthosis for the human ankle joint. The orthosis consisted of a carbon fiber shell, hinge joint, and two artificial pneumatic muscles. One artificial pneumatic muscle provided plantar flexion torque and the second one provided dorsiflexion torque. Computer software adjusted air pressure in each artificial muscle independently so that artificial muscle force was proportional to rectified low-pass-filtered electromyography (EMG) amplitude (i.e., proportional myoelectric control). Tibialis anterior EMG activated the artificial dorsiflexor and soleus EMG activated the artificial plantar flexor. We collected joint kinematic and artificial muscle force data as one healthy participant walked on a treadmill with the orthosis. Peak plantar flexor torque provided by the orthosis was 70 Nm, and peak dorsiflexor torque provided by the orthosis was 38 Nm. The orthosis could be useful for basic science studies on human locomotion or possibly for gait rehabilitation after neurological injury. PMID:16082019

  17. A Pneumatic Actuated Microfluidic Beads-Trapping Device

    SciTech Connect

    Shao, Guocheng; Cai, Ziliang; Wang, Jun; Wang, Wanjun; Lin, Yuehe

    2011-08-20

    The development of a polydimethylsiloxane (PDMS) microfluidic microbeads trapping device is reported in this paper. Besides fluid channels, the proposed device includes a pneumatic control chamber and a beads-trapping chamber with a filter array structure. The pneumatic flow control chamber and the beads-trapping chamber are vertically stacked and separated by a thin membrane. By adjusting the pressure in the pneumatic control chamber, the membrane can either be pushed against the filter array to set the device in trapping mode or be released to set the device in releasing mode. In this paper, a computational fluid dynamics simulation was conducted to optimize the geometry design of the filter array structure; the device fabrication was also carried out. The prototype device was tested and the preliminary experimental results showed that it can be used as a beads-trapping unit for various biochemistry and analytical chemistry applications, especially for flow injection analysis systems.

  18. Retrofitted pneumatic conveying system upgrades ROM coal handling system

    SciTech Connect

    Crawley, M.F. )

    1994-07-01

    This article describes a new pneumatic coal handling system which avoids degrading coal beyond a 5% fines content and controls coal dust in a sensitive fuel storage area. The original pneumatic conveying system for run-of-mine coal no longer met the demands of a nuclear weapons waste material recovery facility in Richland, Wash. Therefore, Kaiser Engineers Hanford Co., which operates the facility for the US Department of Energy, chose to upgrade its pneumatic coal handling system for three rotary grate coal-fired boilers. Installed in October 1993, the newly retrofitted coal yard storage fuel handling system boasts a dust-free capability. It consists of two Denseveyor systems that transfer coal (fuel size 2 inch x 0) from railcar ground hoppers to three service bunkers above the boiler stokers. There also are two dustless outloading towers for yard storage stockpiling.

  19. An ankle-foot orthosis powered by artificial pneumatic muscles.

    PubMed

    Ferris, Daniel P; Czerniecki, Joseph M; Hannaford, Blake

    2005-05-01

    We developed a pneumatically powered orthosis for the human ankle joint. The orthosis consisted of a carbon fiber shell, hinge joint, and two artificial pneumatic muscles. One artificial pneumatic muscle provided plantar flexion torque and the second one provided dorsiflexion torque. Computer software adjusted air pressure in each artificial muscle independently so that artificial muscle force was proportional to rectified low-pass-filtered electromyography (EMG) amplitude (i.e., proportional myoelectric control). Tibialis anterior EMG activated the artificial dorsiflexor and soleus EMG activated the artificial plantar flexor. We collected joint kinematic and artificial muscle force data as one healthy participant walked on a treadmill with the orthosis. Peak plantar flexor torque provided by the orthosis was 70 Nm, and peak dorsiflexor torque provided by the orthosis was 38 Nm. The orthosis could be useful for basic science studies on human locomotion or possibly for gait rehabilitation after neurological injury.

  20. Oil well rabbit

    SciTech Connect

    Yerian, H.W.

    1983-10-18

    A well rabbit is described which has a high gas seal capacity as well as resistance to wear and structural failure. The rabbit comprises a one-piece elongated generally cylindrical body having external circumferential gas-sealing grooves spaced along its length and a set of helically oriented slots at its lower end. The circumferential grooves, which work collectively in the manner of a labyrinth seal, are undercut in a way to deflect escaping gas streams and promote turbulence to enhance their gas-sealing capability. The undercut profile and relative spacing of the grooves leaves a large surface area between the grooves for distributing radial forces and thereby decreasing the wear rate of the rabbit. The helically oriented slots convert energy of upward escaping gas into rotational energy in the rabbit. (3 claims.

  1. Compensating for pneumatic distortion in pressure sensing devices

    NASA Technical Reports Server (NTRS)

    Whitmore, Stephen A.; Leondes, Cornelius T.

    1990-01-01

    A general numerical technique for obtaining unsteady pressure measurements using conventional pressure sensing technology has been developed. A pneumatic distortion model, based on the Navier-Stokes equations of momentum and continuity, was reduced to a low-order, state-variable model retaining most of the dynamic characteristics of the full model. The reduced-order model is coupled with results from minimum variance estimation theory to develop an algorithm to compensate the effects of pneumatic distortion. Both postflight and real-time algorithms were developed and evaluated using simulated and flight data.

  2. Evaluation of a pneumatic Martian soil sampler concept

    NASA Technical Reports Server (NTRS)

    Schaefer, John L.; Neathery, James K.; Stencel, John M.

    1994-01-01

    The pneumatic soil sampler concept was successfully demonstrated by penetrating a Martian simulant soil to a depth of 2 meters. Working gas pressure, composition, and pulsing were evaluated with the objective of minimizing gas usage. Also, the probe penetration force was investigated with the objective of minimizing probe weight. Gas and probe penetration force, while not yet optimized, are within the range which make the soil sampler concept feasible. While the tests described in this report did not answer all the questions and address all the variables associated with pneumatic soil sampling, valuable data experience and knowledge were gained which can be used to further develop the concept.

  3. 12. Pneumatic jack and rollers. To lift the ends of ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    12. Pneumatic jack and rollers. To lift the ends of the draw span to its proper closed position, the Center Street Bridge features a pair of rollers located under the deck of each end of the draw span. The rollers are moved downward by the pistons of a pneumatic jack to support the bridge when closed. To open the draw, the rollers are released and swung upward toward the center of the deck. - Center Street Swing Bridge, Southwest of Public Square, Cleveland, Cuyahoga County, OH

  4. Substance-field Model for Functional Pneumatic Design

    NASA Astrophysics Data System (ADS)

    Xu, Z. G.; Yang, D. Y.; Shen, W. D.; Liu, T. T.

    2017-07-01

    The Substance-field analysis is put forward. The functional analysis method is studied to find out the problem, and an improved algorithm is put forward. The internal combustion engine is taken as an example, the harmful function is recognized, and is improved, i.e, high pressure gas is introduced to remove polluted air. The working principle of pneumatic engine is described, the thermodynamic engineering is analyzed, the energy release amounts are analyzed in the isothermal, polymorphism and adiabatic processes. It is concluded that, the isothermal process releases the most energy than the others. The expansion process of the pneumatic engine should be as close as possible to the isothermal process.

  5. Influence of throttling of pneumatic actuators at the positioning accuracy

    NASA Astrophysics Data System (ADS)

    Hetmanczyk, M. P.; Michalski, P.

    2015-11-01

    Changing the dynamic motion parameters of pneumatic equipment requires control of pressure and the volumetric flow rate. The article presents a study of the impact of setting control parameters and external disturbances on the positioning accuracy of pneumatic rodless double acting actuator. Testing process was carried out at different values of the parameters (adjusted to the actuator) and external loads. The probe mass was selected within guidelines (a cushioning diagram) so that the operating point was placed on the curve of limiting movement speed of the actuator.

  6. Overall life cycle comprehensive assessment of pneumatic and electric actuator

    NASA Astrophysics Data System (ADS)

    Zhang, Yeming; Cai, Maolin

    2014-05-01

    Pneumatic actuators and electric actuators have almost been applied to all manufacturing industries. The two kinds of actuators can replace each other in most fields, such as the point to point transmission occasion and some rotating occasions. However, there are very few research results about the advantages and disadvantages of two kinds of actuators under the same working conditions so far. In this paper, a novel comprehensive assessment method, named as overall life cycle comprehensive assessment (OLCCA), is proposed for comparison and assessment of pneumatic and electric actuators. OLCCA contains mechanical properties evaluation (MPE), life cycle cost analysis based on users (LCCABOU) and life cycle environmental impact analysis (LCEIA) algorithm in order to solve three difficult problems: mechanical properties assessment, cost analysis and environmental impact assessment about actuators. The mechanical properties evaluation of actuators is a multi-objective optimization problem. The fuzzy data quantification and information entropy methods are combined to establish MPE algorithm of actuators. Two kinds of pneumatic actuators and electric actuators with similar bearing capacity and similar work stroke were taken for example to verify the correctness of MPE algorithm. The case study of MPE algorithm for actuators verified its correctness. LCCABOU for actuators is also set up. Considering cost complex structure of pneumatic actuators, public device cost even method (PDCEM) is firstly presented to solve cost division of public devices such as compressors, aftercooler, receivers, etc. LCCABOU method is also effective and verified by the three groups of pneumatic actuators and electric actuators. Finally, LCEIA model of actuators is established for the environmental impact assessment of actuators. LCEIA data collection method and model establishment procedure for actuators are also put forward. With Simapro 7, LCEIA comparison results of six actuators can be

  7. Compensating for pneumatic distortion in pressure sensing devices

    NASA Technical Reports Server (NTRS)

    Whitmore, Stephen A.; Leondes, Cornelius T.

    1990-01-01

    A general numerical technique for obtaining unsteady pressure measurements using conventional pressure sensing technology has been developed. A pneumatic distortion model, based on the Navier-Stokes equations of momentum and continuity, was reduced to a low-order, state-variable model retaining most of the dynamic characteristics of the full model. The reduced-order model is coupled with results from minimum variance estimation theory to develop an algorithm to compensate the effects of pneumatic distortion. Both postflight and real-time algorithms were developed and evaluated using simulated and flight data.

  8. A pneumatic vibrotactile stimulation device for fMRI.

    PubMed

    Briggs, Richard W; Dy-Liacco, Iona; Malcolm, Matthew P; Lee, Hyunsook; Peck, Kyung K; Gopinath, Kaundinya S; Himes, Nathan C; Soltysik, David A; Browne, Paul; Tran-Son-Tay, Roger

    2004-03-01

    Mapping the functional response of the somatosensory cortex is useful both for characterizing normal brain activity and for determining the functional integrity of damaged cortex compromised by stroke or other neurological insults. A variety of stimulators have been used to produce somatosensory cortex activation in functional brain imaging, including brushes and swabs operated manually, pneumatically and mechanically powered mechanical vibrators, air puffs, and vibrating ceramic piezoelectric wafers and benders. A closed-system, pneumatically driven rubber diaphragm is reported that overcomes many of the limitations of existing vibrotactile devices and produces robust sensory cortex activation in an fMRI experiment.

  9. Design considerations for single-stage and two-stage pneumatic pellet injectors

    SciTech Connect

    Gouge, M.J.; Combs, S.K.; Fisher, P.W.; Milora, S.L.

    1988-09-01

    Performance of single-stage pneumatic pellet injectors is compared with several models for one-dimensional, compressible fluid flow. Agreement is quite good for models that reflect actual breech chamber geometry and incorporate nonideal effects such as gas friction. Several methods of improving the performance of single-stage pneumatic pellet injectors in the near term are outlined. The design and performance of two-stage pneumatic pellet injectors are discussed, and initial data from the two-stage pneumatic pellet injector test facility at Oak Ridge National Laboratory are presented. Finally, a concept for a repeating two-stage pneumatic pellet injector is described. 27 refs., 8 figs., 3 tabs.

  10. Viral diseases of the rabbit.

    PubMed

    Krogstad, Aric P; Simpson, Janet E; Korte, Scott W

    2005-01-01

    Viral disease in the rabbit is encountered infrequently by the clinical practitioner; however, several viral diseases were reported to occur in this species. Viral diseases that are described in the rabbit primarily may affect the integument, gastrointestinal tract or, central nervous system or maybe multi-systemic in nature. Rabbit viral diseases range from oral papillomatosis, with benign clinical signs, to rabbit hemorrhagic disease and myxomatosis, which may result in significant clinical disease and mortality. The wild rabbit may serve as a reservoir for disease transmission for many of these viral agents. In general, treatment of viral disease in the rabbit is supportive in nature.

  11. Intermittent pneumatic soft tissue compression: Changes in periosteal and medullary canal blood flow.

    PubMed

    Park, Sang-Hyun; Silva, Mauricio

    2008-04-01

    We previously demonstrated that the use of intermittent pneumatic soft tissue compression (IPC) treatment enhanced fracture healing in an animal model, but the exact mechanism remained unknown. The purpose of this study was to determine the local and remote effects of IPC treatment on blood flow within the medullary canal and outside the periosteum of mid-tibial diaphysis. Blood flow was measured with a Laser Doppler blood flow meter in the lower limbs of 21 rabbits. Laser probes were inserted at three different sites of the mid-diaphysis on the right tibia: in the medullary canal (n = 21), outside the periosteum on the lateral side (n = 11), and outside the periosteum on the medial side (n = 10). IPC was applied for 30 min through cuffs that were placed around the feet and the lower part of the calf. While applying IPC to the left leg, no changes in blood flow occurred on the right leg (remote changes). However, while applying IPC to the right leg, significant localized changes were found on the right leg, including 47 and 89% increases in total amount of blood flow outside the lateral and medial periosteum, respectively. Although an altered blood flow pattern was observed in the medullary canal, no significant change in total amount of blood flow was observed at this level. In summary, the present study demonstrated that the use of IPC in an intact bone model results in a significant local increase in total blood flow, with minimal measurable effects on the contralateral limb.

  12. Irradiation effect of polarization direction and intensity of semiconductor laser on injured peripheral nerve

    NASA Astrophysics Data System (ADS)

    Guo-Xin, Xiong; Lei-lei, Xiong

    2016-08-01

    To investigate the irradiation effect of polarization direction and the intensity of a semiconductor laser on the injured peripheral nerve in rabbits, the model of the injured common peroneal nerve was established, the L5,6 spinal segments of the rabbits were irradiated, a uniform rotating polarizer was placed at the laser output which made the polarization direction and intensity of the output laser change according to the 80 Hz cosine law. The experimental results show that irradiating the spinal segment of injured nerves in rabbits with this changeable semiconductor laser can significantly promote the regeneration of injured peripheral nerves and the function recovery.

  13. Pneumatic vacuum tube message center, basement room 23, looking southeast ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Pneumatic vacuum tube message center, basement room 23, looking southeast toward doorway and corridor. Note soundproof walls, pedestal flooring, and cable tray suspended from the ceiling - March Air Force Base, Strategic Air Command, Combat Operations Center, 5220 Riverside Drive, Moreno Valley, Riverside County, CA

  14. Pneumatic Conveying of Seed Cotton: Minimum Velocity and Pressure Drop

    USDA-ARS?s Scientific Manuscript database

    Electricity is a major cost for cotton gins, representing approximately 20% of variable costs. Fans used for pneumatic conveying consume the majority of electricity at cotton gins. Development of control systems to reduce the air velocity used for conveying seed cotton could significantly decrease e...

  15. Pneumatic Conveying of Seed Cotton: Minimum Velocity and Pressure Drop

    USDA-ARS?s Scientific Manuscript database

    Electricity is major cost for cotton gins, representing approximately 20% of the industry’s variable costs. Fans used for pneumatic conveying consume the majority of electricity at cotton gins. Development of control systems to reduce the air velocity used for conveying seed cotton could significant...

  16. Adaptive backstepping slide mode control of pneumatic position servo system

    NASA Astrophysics Data System (ADS)

    Ren, Haipeng; Fan, Juntao

    2016-09-01

    With the price decreasing of the pneumatic proportional valve and the high performance micro controller, the simple structure and high tracking performance pneumatic servo system demonstrates more application potential in many fields. However, most existing control methods with high tracking performance need to know the model information and to use pressure sensor. This limits the application of the pneumatic servo system. An adaptive backstepping slide mode control method is proposed for pneumatic position servo system. The proposed method designs adaptive slide mode controller using backstepping design technique. The controller parameter adaptive law is derived from Lyapunov analysis to guarantee the stability of the system. A theorem is testified to show that the state of closed-loop system is uniformly bounded, and the closed-loop system is stable. The advantages of the proposed method include that system dynamic model parameters are not required for the controller design, uncertain parameters bounds are not need, and the bulk and expensive pressure sensor is not needed as well. Experimental results show that the designed controller can achieve better tracking performance, as compared with some existing methods.

  17. 117. PNEUMATIC SUPPLY PANEL IN CENTER OF VEHICLE MECHANICAL SYSTEMS ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    117. PNEUMATIC SUPPLY PANEL IN CENTER OF VEHICLE MECHANICAL SYSTEMS ROOM (111), LSB (BLDG. 770), FACING NORTH. CONTROLS FOR FLOW AND PRESSURE REGULATION OF HELIUM ON LEFT SIDE OF PANEL; CONTROLS FOR NITROGEN ON RIGHT SIDE OF PANEL (AT RIGHT EDGE OF PHOTO). - Vandenberg Air Force Base, Space Launch Complex 3, Launch Pad 3 West, Napa & Alden Roads, Lompoc, Santa Barbara County, CA

  18. 116. PNEUMATIC SUPPLY PANEL IN CENTER OF VEHICLE MECHANICAL SYSTEMS ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    116. PNEUMATIC SUPPLY PANEL IN CENTER OF VEHICLE MECHANICAL SYSTEMS ROOM (111) OF LSB (BLDG. 770), FACING NORTH. CONTROLS FOR FLOW AND PRESSURE REGULATION OF NITROGEN ON RIGHT SIDE OF PANEL; CONTROLS FOR HELIUM ON LEFT SIDE OF PANEL (AT LEFT EDGE OF PHOTO). - Vandenberg Air Force Base, Space Launch Complex 3, Launch Pad 3 West, Napa & Alden Roads, Lompoc, Santa Barbara County, CA

  19. 21 CFR 890.3610 - Rigid pneumatic structure orthosis.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Rigid pneumatic structure orthosis. 890.3610 Section 890.3610 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES PHYSICAL MEDICINE DEVICES Physical Medicine Prosthetic Devices § 890.3610 Rigid...

  20. Embedded Triboelectric Active Sensors for Real-Time Pneumatic Monitoring.

    PubMed

    Fu, Xian Peng; Bu, Tian Zhao; Xi, Feng Ben; Cheng, Ting Hai; Zhang, Chi; Wang, Zhong Lin

    2017-09-20

    Pneumatic monitoring sensors have great demands for power supply in cylinder systems. Here, we present an embedded sliding triboelectric nanogenerator (TENG) in air cylinder as active sensors for position and velocity monitoring. The embedded TENG is composed of a circular poly(tetrafluoroethylene) polymer and a triangular copper electrode. The working mechanism as triboelectric active sensors and electric output performance are systematically investigated. By integrating into the pneumatic system, the embedded triboelectric active sensors have been used for real-time air pressure/flow monitoring and energy storage. Air pressures are measured from 0.04 to 0.12 MPa at a step of 0.02 MPa with a sensitivity of 49.235 V/MPa, as well as airflow from 50 to 250 L/min at a step of 50 L/min with a sensitivity of 0.002 μA·min/L. This work has first demonstrated triboelectric active sensors for pneumatic monitoring and may promote the development of TENG in intelligent pneumatic system.

  1. Assessing a pneumatic fractionator as a lint cleaning device

    USDA-ARS?s Scientific Manuscript database

    A study assessed a pneumatic fractionator as a lint cleaning device for ginned lint. Results from a test that used two line pressures and three fractionation times showed that higher line pressure and longer fractionation time produced fiber that was shorter in staple length, contained more neps, a...

  2. Low-energy pneumatic control of forebody vortices

    NASA Technical Reports Server (NTRS)

    Roos, Frederick W.

    1994-01-01

    This research will be exploring the prospect of employing bluntness, known to suppress the tendency toward asymmetry on slender forebodies, jointly with pneumatic manipulation as a system of forebody asymmetry control. The influences of jet location and direction, blowing rate, relative noise bluntness, angle of attack, and state of flow separation feeding the vortices (laminar vs. turbulent) will be evaluated.

  3. 21 CFR 890.3610 - Rigid pneumatic structure orthosis.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Rigid pneumatic structure orthosis. 890.3610 Section 890.3610 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES PHYSICAL MEDICINE DEVICES Physical Medicine Prosthetic Devices § 890.3610...

  4. 14 CFR 23.1438 - Pressurization and pneumatic systems.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 14 Aeronautics and Space 1 2014-01-01 2014-01-01 false Pressurization and pneumatic systems. 23.1438 Section 23.1438 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF... elements must be burst pressure tested to 2.0 times, and proof pressure tested to 1.5 times, the maximum...

  5. 14 CFR 25.1438 - Pressurization and pneumatic systems.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 14 Aeronautics and Space 1 2014-01-01 2014-01-01 false Pressurization and pneumatic systems. 25.1438 Section 25.1438 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF... pressure tested to 2.0 times, and proof pressure tested to 1.5 times, the maximum normal operating pressure...

  6. The Pneumatic Common: Learning in, with and from the Air

    ERIC Educational Resources Information Center

    Ford, Derek R.

    2015-01-01

    Air is an immersive substance that envelopes us and binds us together, yet it has dominantly been taken for granted and left out of educational and other theorizations. This article develops a conceptualization of the "pneumatic common" in order to address this gap. The specific intervention staged is within recent educational literature…

  7. 60. Shock isolator at center, pneumatic control group panel at ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    60. Shock isolator at center, pneumatic control group panel at left, power distribution box at right, all at right of entrance to lcc. - Ellsworth Air Force Base, Delta Flight, Launch Control Facility, County Road CS23A, North of Exit 127, Interior, Jackson County, SD

  8. 21 CFR 890.3610 - Rigid pneumatic structure orthosis.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Rigid pneumatic structure orthosis. 890.3610 Section 890.3610 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... for medical purposes to provide whole body support by means of a pressurized suit to help...

  9. 21 CFR 890.3610 - Rigid pneumatic structure orthosis.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Rigid pneumatic structure orthosis. 890.3610 Section 890.3610 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... for medical purposes to provide whole body support by means of a pressurized suit to help...

  10. 21 CFR 890.3610 - Rigid pneumatic structure orthosis.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Rigid pneumatic structure orthosis. 890.3610 Section 890.3610 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES PHYSICAL MEDICINE DEVICES Physical Medicine Prosthetic Devices § 890.3610...

  11. Trombay infrared pneumatic detector: theory of operational characteristics.

    PubMed

    Sachdev, R N; Gupta, J P; Vohra, K G

    1978-11-01

    This paper explains in a simple manner the mechanism of formation of pressure pulse inside a pneumatic detector due to incident ir radiation. The detector had been designed earlier at Trombay. Experimentally observed characteristics of the detector have been explained on the basis of the theory derived.

  12. Characteristics of pneumatically-emplaced dry flue gas desulfurization materials

    SciTech Connect

    Carter, S.D.; Rathbone, R.F.; Graham, U.M.; Robl, T.L.

    1996-12-31

    The University of Kentucky in collaboration with the Department of Energy, Addington, Inc. and Costain Coal is currently developing a commercial concept for the haul back of dry flue gas desulfurization materials (FGDM) into highwall mine adits. The University`s Center for Applied Energy Research (CAER) is investigating emplacement systems for a mine demonstration which is planned for the third quarter of 1996. A laboratory-scale transport system has been built at the CAER to evaluate the potential of pneumatic transport for FGDM emplacement. The system is modeled after shotcreting systems in which water is mixed with cement (FGDM) in a nozzle at the end of the pneumatic pipe. Solids travel approximately 70 ft in the lab-scale system at a rate of up to 6 lb FGDM/minute prior to impingement onto a sample collector. Prehydrated FGDM from a circulating fluidized bed combustor has been successfully emplaced onto vertically positioned sample surfaces without excessive dust liberation. The test program is focussed on determining the pneumatic conditions necessary to maximize the strength of the emplaced FGDM under anticipated mine curing conditions while minimizing dust formation. The mineralogy and strength of a pneumatically created sample are described following curing for 60 days.

  13. A Synchronous Mutual Position Control for Vertical Pneumatic Servo System

    NASA Astrophysics Data System (ADS)

    Shibata, Satoru; Yamamoto, Tomonori; Jindai, Mitsuru

    Synchronous control of mutual position for two vertical-type pneumatic servo systems is discussed for practical use in this study. In the proposed control system, a fuzzy controller is used in each pneumatic servo system so that the output of each plant can follow the reference input. A PD controller is introduced to realize the synchronization of both pneumatic servo systems, in which the outputs from this controller are the inputs for revision to both plants. A fuzzy virtual reference generator that can adjust the reference input to both fuzzy controllers adaptively by fuzzy rules is constructed to improve the transient performances of both axes. In addition, the adjustment controller produces a representative value of both cylinder outputs, which is used to synthesize the inputs to the fuzzy virtual reference generator, in order to reach a compromise between the follow-up ability to the reference input in each axis and synchronization of both axes. The applicability of the proposed method is confirmed by experiments using two existent vertical-type pneumatic servo systems.

  14. Fluidics and pneumatics: principles and applications in anaesthesia.

    PubMed

    Duffin, J

    1977-01-01

    This article describes the construction and operation of fluidic and pneumatic devices in current use, as well as the principles of their use in medical devices. The designs for an automatic blood pressure cuff inflator, a blood pump and a high performance ventilator are presented.

  15. Control and monitoring system for clinically employed pneumatic blood pumps.

    PubMed

    Normann, N A; Henrichsen, D W; Cooper, T G; King, R E; Noon, G P; DeBakey, M E

    1977-01-01

    Instantaneous position of the flexing member in pneumatic blood pumps is monitored on-line by measuring the electrical capacitance across the gas space within the pump. Monitor output is utilized in closed-loop pump control and for automatic pump shutdown in response to operational abnormalities. Thus, safety and efficacy are enhanced through operational optimization, automatic safety features, and facilitated evaluation.

  16. The Pneumatic Common: Learning in, with and from the Air

    ERIC Educational Resources Information Center

    Ford, Derek R.

    2015-01-01

    Air is an immersive substance that envelopes us and binds us together, yet it has dominantly been taken for granted and left out of educational and other theorizations. This article develops a conceptualization of the "pneumatic common" in order to address this gap. The specific intervention staged is within recent educational literature…

  17. Pneumatic Power Drive Wheel and related assembly for Turntable, with ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Pneumatic Power Drive Wheel and related assembly for Turntable, with scale. Not in use August 1994. Turntable rotated with engine and tender on balance by two persons, one on either side at ground level - East Broad Top Railroad & Coal Company, Roundhouse, State Route 994, West of U.S. Route 522, Rockhill Furnace, Huntingdon County, PA

  18. a Study of the Systematics of Low-Lying Levels in Nuclei in the Mass Region A=80 with a NIM Controlled Rabbit System.

    NASA Astrophysics Data System (ADS)

    Fry, Leolan Harold, Jr.

    Heavy ion reactions were used to produce nuclei away from beta stability in the mass region A(TURNEQ)80. The irradiated targets were transported to an isolated detector site using a rapid target transfer (Rabbit) system to aid in the study of weak products produced in these reactions and to protect the Ge(Li) detectors used in the experiments. The "Rabbit" system constructed for this purpose was a pneumatic type and was controlled by a NIM controller. The NIM controller, a unique feature of this system, was constructed with TTL and CMOS circuits and works in conjunction with a leaky integrator and a UNIVAC 6130 computer. The "Rabbit" system was used in lifetime, gamma-gamma coincidence measurements and beta-gamma coincidence measurements. Lifetime measurements were used to study the decay of ('79)Sr produced in the reaction ('54)Fe + ('28)Si at 90 MeV (lab). The lifetime of the ground state of ('79)Sr was measured and a positron feeding to the 39.3-keV level in ('79)Rb was established. Lifetime measurements were also used to study the decay of ('81m)Rb, which is produced in the reaction ('68)Zn + ('16)O at 56 MeV (lab). A positron feeding from the isomeric level in ('81)Rb to the 49.6 -keV level in ('81)Kr was established. In addition, lifetime measurements were used to help identify gamma rays produced in the reactions ('68)Zn + ('16)O and ('70)Ge + ('16)O at 56 MeV (lab). The reaction ('68)Zn + ('16)O was also studied with the gamma-gamma coincidence technique. Extensive level schemes were constructed and new levels were established for the decays of ('81)Rb and ('81)Sr. The beta-gamma coincidence technique was used in the study of the reaction ('70)Ge + ('16)O to investigate the ground state and isomeric levels of ('83)Y and ('84)Y. The order and relative separation of these levels were tentatively established for ('83)Y. The Q-value and J('(pi)) of the ground state were established and tentative J('(pi)) assignments were made for the isomeric levels in ('84)Y

  19. Dimensions, septation, and pattern of pneumatization of the sphenoidal sinus.

    PubMed

    Idowu, O E; Balogun, B O; Okoli, C A

    2009-11-01

    The endoscopic endonasal transsphenoidal approach (EEA) to treat sellar, parasellar, and suprasellar tumours continues to gain increased significance. Due to the close proximity of the sphenoid sinus to the carotid artery and the optic canal, it is very important for surgeons to know the anatomical features and variations of the sphenoid sinus as relevant to EEA. A prospective study of the sphenoid sinus morphology was carried out on the cranial tomographic (CT) scan images of 60 Nigerian adult patients. The CTs were reviewed regarding the different anatomical variations of the sphenoid sinus: dimensions, septation, and pattern of pneumatisation. There were 37 males and 23 females. The patients' ages ranged from 18 years to 85 years, with a mean of 47.2 years. There was a main single intersphenoid septum in most patients (95%). The insertion of the septum was usually to the right posteriorly (38%) and in the midline anterior (65%). Although there is usually a main septum, the septa present were multiple in 29 of the sinuses studied. There was no gender difference with respect to the attachment of the main sphenoid sinus septum. The sphenoid anterior, posterior, and transverse dimensions were not significantly dependent on age, but they were longer in males than in females. Sellar pneumatization was present in the majority of the patients (83%), with 4 patients having postsellar pneumatization (6.7%) and 3 patients having presellar pneumatization (5%). There were no cases with conchal pneumatization or lateral pneumatization of the greater wing of the sphenoid. The present study provides anatomical information about the sphenoid sinus dimensions morphology that is essential for avoiding complications in performing an endoscopic sphenoidotomy.

  20. Pneumatic fractures in Confined Granular Media

    NASA Astrophysics Data System (ADS)

    Eriksen, Fredrik K.; Toussaint, Renaud; Jørgen Måløy, Knut; Grude Flekkøy, Eirik; Turkaya, Semih

    2016-04-01

    We will present our ongoing study of the patterns formed when air flows into a dry, non-cohesive porous medium confined in a horizontal Hele-Shaw cell. This is an optically transparent system consisting of two glass plates separated by 0.5 to 1 mm, containing a packing of dry 80 micron beads in between. The cell is rectangular and has an air-permeable boundary (blocking beads) at one short edge, while the other three edges are completely sealed. The granular medium is loosely packed against the semi-permeable boundary and fills about 80 % of the cell volume. This leaves an empty region at the sealed side, where an inlet allows us to set and maintain the air at a constant overpressure (0.1 - 2 bar). For the air trapped inside the cell to relax its overpressure it has to move through the deformable granular medium. Depending on the applied overpressure and initial density of the medium, we observe a range of different behaviors such as seepage through the pore-network with or without an initial compaction of the solid, formation of low density bubbles with rearrangement of particles, granular fingering/fracturing, and erosion inside formed channels/fractures. The experiments are recorded with a high-speed camera at a framerate of 1000 images/s and a resolution of 1024x1024 pixels. We use various image processing techniques to characterize the evolution of the air invasion patterns and the deformations in the surrounding material. The experiments are similar to deformation processes in porous media which are driven by pore fluid overpressure, such as mud volcanoes and hydraulic or pneumatic (gas-induced) fracturing, and the motivation is to increase the understanding of such processes by optical observations. In addition, this setup is an experimental version of the numerical models analyzed by Niebling et al. [1,2], and is useful for comparison with their results. In a directly related project [3], acoustic emissions from the cell plate are recorded during

  1. Design and Dynamic Model of a Frog-inspired Swimming Robot Powered by Pneumatic Muscles

    NASA Astrophysics Data System (ADS)

    Fan, Ji-Zhuang; Zhang, Wei; Kong, Peng-Cheng; Cai, He-Gao; Liu, Gang-Feng

    2017-09-01

    Pneumatic muscles with similar characteristics to biological muscles have been widely used in robots, and thus are promising drivers for frog inspired robots. However, the application and nonlinearity of the pneumatic system limit the advance. On the basis of the swimming mechanism of the frog, a frog-inspired robot based on pneumatic muscles is developed. To realize the independent tasks by the robot, a pneumatic system with internal chambers, micro air pump, and valves is implemented. The micro pump is used to maintain the pressure difference between the source and exhaust chambers. The pneumatic muscles are controlled by high-speed switch valves which can reduce the robot cost, volume, and mass. A dynamic model of the pneumatic system is established for the simulation to estimate the system, including the chamber, muscle, and pneumatic circuit models. The robot design is verified by the robot swimming experiments and the dynamic model is verified through the experiments and simulations of the pneumatic system. The simulation results are compared to analyze the functions of the source pressure, internal volume of the muscle, and circuit flow rate which is proved the main factor that limits the response of muscle pressure. The proposed research provides the application of the pneumatic muscles in the frog inspired robot and the pneumatic model to study muscle controller.

  2. The Cutaneous Rabbit Revisited

    ERIC Educational Resources Information Center

    Flach, Rudiger; Haggard, Patrick

    2006-01-01

    In the cutaneous rabbit effect (CRE), a tactile event (so-called attractee tap) is mislocalized toward an adjacent attractor tap. The effect depends on the time interval between the taps. The authors delivered sequences of taps to the forearm and asked participants to report the location of one of the taps. The authors replicated the original CRE…

  3. The Cutaneous Rabbit Revisited

    ERIC Educational Resources Information Center

    Flach, Rudiger; Haggard, Patrick

    2006-01-01

    In the cutaneous rabbit effect (CRE), a tactile event (so-called attractee tap) is mislocalized toward an adjacent attractor tap. The effect depends on the time interval between the taps. The authors delivered sequences of taps to the forearm and asked participants to report the location of one of the taps. The authors replicated the original CRE…

  4. Autoantibody Production in Rabbits

    PubMed Central

    Asherson, G. L.; Dumonde, D. C.

    1963-01-01

    The sera of rabbits injected with rat liver, kidney, heart, muscle, spleen and brain in Freund's complete adjuvant fixed complement with rabbit tissue. This complement-fixing activity was attributed to autoantibodies which were able to fix complement in vitro with the tissue of the rabbit in which they occurred. Absorption, gel diffusion and antibody and antigen titrations indicated that some of the anti-liver, anti-kidney, anti-heart, anti-muscle and anti-brain sera contained organ-specific autoantibody. The sera also contained autoantibody reacting with widely distributed antigen(s), which was relatively labile at 65°. The anti-kidney and anti-brain sera reacted with distinct antigens which were extracted from rabbit kidney and brain with a mixture of chloroform and methanol. The natural autoantibody of Kidd and Friedewald was usually labile at 65° and behaved like a macroglobulin on sucrose gradient centrifugation. Sera taken 1 week after immunization with rat tissue contained heat-labile macroglobulin antibody. However, sera taken 1 month after immunization also contained small molecular weight antibody which was stable at 65°. PMID:13965166

  5. [Comparison of photodynamic effect with respect to human and rabbit erythrocytes].

    PubMed

    Galebskaia, L V; Solovtsova, I L; Solov'eva, M A; Zammoeva, D B; Kuz'menkov, A N

    2011-01-01

    Parameters of photoinduced lysis are studied for human and rabbit erythrocytes (photosensibilizer--Radachlorin, the light source--Shuttle HeNe lazer, lambda = 633 nm). The higher sensitivity to irradiation is revealed for rabbit erythrocytes. Treatment of erythrocytes with trypsin showed the surface proteins in human cells to produce a protective effect. Trypsynization of rabbit erythrocytes produced the opposite action--the rate of photohemolysis increased. Results of the study indicate the differences in sensitivity to the photoinduced lysis of erythrocytes of different species and participation of erythrocytes proteins in the effect of photohemolysis.

  6. Autoantibody production in rabbits

    PubMed Central

    Asherson, G. L.; Holborow, E. J.

    1966-01-01

    Rabbits received two injections of dead bacteria in Freund's complete adjuvant. One month later the sera of the rabbits were examined for autoantibodies against gut by indirect immunofluorescence using the rabbit's own stomach, ileum and colon taken at post mortem. Autoantibodies against colon were found in three out of seven rabbits injected with one particular strain of Escherichia coli O64 and in a few animals injected with other E. coli, Salmonella arizona, Proteus mirabilis, Klebsiella pneumoniae and Streptococcus faecalis. The antigen, with which the autoantibodies reacted, behaved like mucus and was detected in the colon and sometimes in the ileum and the stomach. Three patterns of staining were observed: (a) staining of the superficial mucosa of the colon with sparing of the deep glands; (b) staining of scattered groups of glands in the deepest part of the colon with sparing of the superficial glands (this pattern of staining was associated with staining of the superficial mucosa of the body of the stomach); and (c) staining of both the superficial and deep glands of the colon. None of the sera tested reacted with the bronchial or salivary glands. Polysaccharide preparations of the colon, but not the stomach, inhibited the reaction of the autoantibodies with colon in the sera tested. The amount of antigen needed to inhibit the basal staining was much greater than that needed to inhibit the superficial staining. It was concluded that rabbits may produce autoantibodies to colon and in some cases to ileum and stomach following the injection of certain dead bacteria in Freund's complete adjuvant. ImagesFIGS. 1-2FIG. 3FIG. 4FIG. 5FIG. 6 PMID:4956607

  7. Relief of vasospasm by intravascular ultraviolet irradiation

    NASA Astrophysics Data System (ADS)

    Nakai, Kanji; Morimoto, Yuji; Ito, Hirotaka; Kominami, Kimito; Matsuo, Hirotaka; Arai, Tsunenori; Kikuchi, Makoto

    1998-05-01

    We investigated the photovasorelaxation with intravascular transluminal irradiation using in vivo model. A 2.5 Fr. catheter was inserted in the femoral artery of a rabbit under anesthesia. A 400 micrometers diameter quartz fiber was inserted through the catheter. The catheter was withdrawn from the distal end to the proximal end of the exposed femoral artery without laser irradiation in order to observe the mechanical dilation by the procedure. The femoral artery lumen was irradiated by a Helium-Cadmium(He-Cd) laser (wavelength; 325 nm) with 8 mW through the fiber during 30 s. We carried out that the laser irradiation produced vasorelaxation (185% on the average) compared with mechanical vasodilation (150% on the average) with angiography. The results suggest that intravascular transluminal irradiation with low-power UV laser might be applicable to the relief of acute arterial vasospasm.

  8. A new sauropod dinosaur from the Early Cretaceous of Tunisia with extreme avian-like pneumatization.

    PubMed

    Fanti, Federico; Cau, Andrea; Hassine, Mohsen; Contessi, Michela

    2013-01-01

    Recent interpretations of the postcranial anatomy of sauropod dinosaurs differ about pneumatic features supporting an avian-like ventilatory system; the most conservative workers reject most postcranial pneumatizations as being unambiguous evidence of abdominal air sacs. Here we describe the first articulated dinosaur skeleton from Tunisia and refer it to a new rebbachisaurid sauropod, Tataouinea hannibalis gen. et sp. nov. The Tunisian specimen shows a complex pattern of caudosacral and pelvic pneumatization--including the first report of an ischial pneumatic foramen among Dinosauria--strongly supporting the presence of abdominal air sacs. Character optimization among Rebbachisauridae indicates that in the caudal vertebrae, pneumatization of the neural arches preceded that of the centra; in the pelvis, pneumatization of the bones adjacent to the sacrum preceded that of more distal elements. Tataouinea was more closely related to European nigersaurines than to otherwise Gondwanan rebbachisaurids; this supports an Afro-European route for rebbachisaurid dispersal.

  9. Development of robot hand with pneumatic actuator and construct of master-slave system.

    PubMed

    Nishino, Shinya; Tsujiuchi, Nobutaka; Koizumi, Takayuki; Komatsubara, Hiroyuki; Kudawara, Tatuwo; Shimizu, Mikio

    2007-01-01

    Recently, research has concentrated on robots that can coexist with people and be of use to them. Such a robot needs to be both safe and flexible. Here, we use a pneumatic actuator as the driving source of a robot hand. We develop a pneumatic actuator driven by low pressure because we consider that the conventional pneumatic actuator is inadequate for the driving source of a robot hand. First, we examine the characteristics of our new pneumatic actuator. Next, we develop a five-fingered robot hand using this pneumatic actuator. The robot hand produced is both safe and flexible. We construct a master-slave system to enable the robot hand to perform the same operations as a human hand. Next, we make a joint model that has one degree of freedom using a pneumatic actuator. We construct a control system for the joint model and verify its control performance.

  10. Quantification of dynamic property of pneumatic muscle actuator for design of therapeutic robot control.

    PubMed

    Balasubramanian, Sivakumar; Huang, He; He, Jiping

    2006-01-01

    Robot-assisted therapy has shown potential in neuromotor rehabilitation. A therapeutic robot driven by pneumatic muscle actuators has been developed in our research group. However, the design of fine and real-time feedback robot control is a challenge. One of the difficulties is the lack of a general dynamic model of the pneumatic muscle actuator. In this study, a phenomenological model has been developed to quantify the dynamic behavior of pneumatic muscle actuator by fitting the experimental length response of the pneumatic muscle, to a step pressure input. In addition, comparison of the dynamic responses of two pneumatic muscles of different dimensions has also been studied. Several control strategies for the pneumatic muscle actuator are discussed based on the results from this study.

  11. Pneumatic protection applied to an airbag for para-gliders

    NASA Astrophysics Data System (ADS)

    Raievski, V.; Valladas, G.

    1998-02-01

    We present a theory of pneumatic protection based on the laws of thermodynamics, elasticity and fluid mechanics. A general pneumatic protection system is made up of several communicating compartments, the differences in pressure of the compartments generating a transfer of mass and energy between them. The transfer offers interesting possibilities to improve the performance of the system. An example of this type of protection in aerial sport is the airbag for para-gliders, it is used in this paper to illustrate the theory. As the pressure in the airbag depends uniquely on its volume, the geometric model in the theory can be simplified. Experiments carried out with crash-test dummies equipped with sensors have confirmed the theoretical predictions.

  12. A skin indentation system using a pneumatic bellows.

    PubMed

    Ferguson-Pell, M; Hagisawa, S; Masiello, R D

    1994-01-01

    A pneumatic indentation system using a copper bellows has been developed for physiological studies where a controlled uniaxial compressive force is required to be applied to the surface of the skin. Such a system is useful for studies where the physiological response of the tissues is to be monitored following a known loading history. The indentation system is driven by a vacuum/compression pneumatic pump through solenoid valves under closed-loop computer control. A load cell placed between the indentor and bellows monitors the applied force providing a feedback signal to the computer. The signal from the computer activates the valves supplying air pressure to the bellows, and the applied force is controlled using a digital closed-loop protocol. This system can be used to provide a controlled loading sequence to the skin without utilizing gravitational forces, which allows the subject to keep a more natural position during the experiment.

  13. Neuro-Fuzzy Control for Pneumatic Servo System

    NASA Astrophysics Data System (ADS)

    Shibata, Satoru; Jindai, Mitsuru; Yamamoto, Tomonori; Shimizu, Akira

    A learning method for acquiring the appropriate fuzzy rules using error back propagation to improve the control performance of the pneumatic servo system is presented in this paper. In the proposed method, two criteria are defined and are adjusted so as to minimize them using error back propagation. These criteria are defined on the fuzzy rules, that is, shapes of membership functions of antecedent clause and real values of consequent clause in the fuzzy controller. Two differentiating coefficients of the plant, used in error back propagation with respect to those criteria, are estimated by the newly established neural network. Moreover, sigmoid function is introduced for the connection of the neural network to compensate for the effect of non-linearity of the system. The method was applied to an existent vertical type pneumatic servo system and proved its effectiveness for practical use.

  14. Liquid-metal dip seal with pneumatic spring

    DOEpatents

    Poindexter, Allan M.

    1977-01-01

    An improved liquid-metal dip seal for sealing the annulus between rotating plugs in the reactor vessel head of a liquid-metal fast-breeder nuclear reactor has two legs of differing widths communicating under a seal blade; the wide leg is also in communication with cover gas of the reactor and the narrow leg is also in communication with an isolated plug annulus above the seal. The annulus contains inert gas which acts as a pneumatic spring. Upon increasing cover gas pressure which depresses the level in the wide leg and greatly increases the level in the narrow leg, the pneumatic spring is compressed, and resists further level changes, thus preventing radioactive cover gas from bubbling through the seal.

  15. Dielectric elastomer actuators used for pneumatic valve technology

    NASA Astrophysics Data System (ADS)

    Giousouf, Metin; Kovacs, Gabor

    2013-10-01

    Dielectric elastomer actuators have been investigated for applications in the field of pneumatic automation technology. We have developed different valve designs with stacked dielectric elastomer actuators and with integrated high voltage converters. The actuators were made using VHB-4910 material and a stacker machine for automated fabrication of the cylindrical actuators. Typical characteristics of pneumatic valves such as flow rate, power consumption and dynamic behaviour are presented. For valve construction the force and stroke parameters of the dielectric elastomer actuator have been measured. Further, benefits for valve applications using dielectric elastomers are shown as well as their potential operational area. Finally, challenges are discussed that are relevant for the use of elastomer actuators in valves for industrial applications.

  16. Pneumatic Regolith Transfer Systems for In-Situ Resource Utilization

    NASA Technical Reports Server (NTRS)

    Mueller, Robert P.; Townsend, Ivan I., III; Mantovani, James G.

    2010-01-01

    One aspect of In-Situ Resource Utilization (lSRU) in a lunar environment is to extract oxygen and other elements from the minerals that make up the lunar regolith. Typical ISRU oxygen production processes include but are not limited to hydrogen reduction, carbothermal and molten oxide electrolysis. All of these processes require the transfer of regolith from a supply hopper into a reactor for chemical reaction processing, and the subsequent extraction of the reacted regolith from the reactor. This paper will discuss recent activities in the NASA ISRU project involved with developing pneumatic conveying methods to achieve lunar regolith simulant transfer under I-g and 1/6-g gravitational environments. Examples will be given of hardware that has been developed and tested by NASA on reduced gravity flights. Lessons learned and details of pneumatic regolith transfer systems will be examined as well as the relative performance in a 1/6th G environment

  17. Development of pneumatic thrust-deflecting powered-lift systems

    NASA Technical Reports Server (NTRS)

    Englar, R. J.; Nichols, J. H., Jr.; Harris, M. J.; Eppel, J. C.; Shovlin, M. D.

    1986-01-01

    Improvements introduced into the Circulation Control Wing/Upper Surface Blowing (CCW/USB) STOL concept (Harris et al., 1982) are described along with results of the full-scale static ground tests and model-scale wind tunnel investigations. Tests performed on the full-scale pneumatic thrust-deflecting system installed on the NASA QSRA aircraft have demonstrated that, relative to the original baseline configuration, a doubling of incremental thrust deflection due to blowing resulted from improvements that increased the blowing span and momentum, as well as from variations in blowing slot height and geometry of the trailing edge. A CCW/Over the Wing model has been built and tested, which was shown to be equivalent to the CCW/USB system in terms of pneumatic thrust deflection and lift generation, while resolving the problem of cruise thrust loss due to exhaust scrubbing on the wing upper surface.

  18. Development of an Autonomous Transfer Machine Using Pneumatic Actuators

    NASA Astrophysics Data System (ADS)

    Hayakawa, Yasuhiro; Pandian, Shunmugham Raj; Kawamura, Sadao

    In this paper, we propose a new type of Autonomous Transfer Machine (ATM) by making use of pneumatic actuators such as pneumatic cylinders and bellows actuators. In the lifting part, the lifting arm which is constructed with a cylinder is rotated by antagonized bellows actuators. Moreover, the support part that a user leans on is supported by antagonized bellows actuators. Since the bellows actuator has a force sensing ability that acts both a force sensor and an actuator, external force that the user leans on the supporter can be estimated. In the standing-up motion, the support part is controlled by both the inclination of the support part and the force difference between holding force and supporting force. Therefore, the lifting trajectory of the supporter can be realized by the posture of the user. In this paper, we clear the effectiveness of the ATM with the standing-up motion from experimental results.

  19. Nonlinear Vibrational Behaviour of an Elasto-Pneumatic Training Tool

    NASA Astrophysics Data System (ADS)

    Körner, Claudia; Hetzler, Hartmut; Seemann, Wolfgang

    This paper deals with the nonlinear vibrational response of a stepping-board with nonlinear elasto-pneumatic force elements. Experimental investigations often show too high vertical ground reaction forces (VGRF) between the test persons and the training tool during exercises. The goal of this contribution is to identify the main factors of the dynamical behaviour and thus the biomechanical impact on humans of this training tool. Therefore this paper presents a mechanical model in order to investigate the interaction between the nonlinear behaviour of the board and the athlete. The multiphysical modelling consists of the linear-elastic structural stiffness part and the nonlinear part due to the pneumatic components. This leads to a nonlinear ordinary differential equation.

  20. Massive Pulmonary Calculi Embolism: A Novel Complication of Pneumatic Lithotripsy

    PubMed Central

    Zhang, Lin; Zhou, Yiwu

    2015-01-01

    Abstract Pneumatic lithotripsy is a minimally invasive technique mainly for the treatment of urinary staghorn stones. Previous literatures have reported some therapeutic complications during or after this procedure, but calculi embolism has not been mentioned before. We report here a fatal case of calculi-induced pulmonary embolism in an adult woman who underwent pneumatic lithotripsy. An autopsy did not reveal any evidence of pulmonary embolism. However, light microscopy revealed noticeable presence of calculi in pulmonary arterioles and capillaries, as evidenced by environmental scanning electron microscope and energy dispersive X-ray analysis. The primary determinants of calculi embolism include intrarenal pressure, and volume and viscosity of the calculi fragments formation. Vascular intravasation of smashed calculi might increase pulmonary vascular resistance and hypoxemia and decrease cardiac output. This case report intends to provide information for clinicians to consider the probability of intraoperative calculi embolism during lithotripsies when patients develop typical symptoms of acute pulmonary embolism. PMID:26222867

  1. A pneumatic sample changer for gamma-ray spectroscopy

    USGS Publications Warehouse

    Massoni, C.J.; Fones, R.V.; Simon, F.O.

    1973-01-01

    A gravity-feed, pneumatic-ejection sample changer has been developed. The changer is suitable for both flat and well-type detectors and permits the continuous use of gamma-ray spectroscopy equipment 24 h a day, 7 days a week. The electronic circuitry has a fail-safe feature which stops the operation of the changer if a malfunction occurs. ?? 1973 The American Institute of Physics.

  2. Pneumatic Muscle Actuated Equipment for Continuous Passive Motion

    NASA Astrophysics Data System (ADS)

    Deaconescu, Tudor T.; Deaconescu, Andrea I.

    2009-10-01

    Applying continuous passive rehabilitation movements as part of the recovery programme of patients with post-traumatic disabilities of the bearing joints of the inferior limbs requires the development of new high performance equipment. This chapter discusses a study of the kinematics and performance of such a new, continuous passive motion based rehabilitation system actuated by pneumatic muscles. The utilized energy source is compressed air ensuring complete absorption of the end of stroke shocks, thus minimizing user discomfort.

  3. Cardiopulmonary resuscitation with a hydraulic-pneumatic band.

    PubMed

    Halperin, H; Berger, R; Chandra, N; Ireland, M; Leng, C; Lardo, A; Paradis, N

    2000-11-01

    Improved blood flow during cardiopulmonary resuscitation (CPR) has been shown to enhance survival from cardiac arrest. Chest compression with a circumferential pneumatic vest enhances blood flow, but the size, weight, and energy consumption of the inflation system limit its portability and, thereby, have made clinical studies difficult. The purpose of this investigation was to study an improved circumferential chest compression device that uses a constricting band that is pneumatically actuated. The constricting band applies its force to a hydraulic cushion that contacts the anterior and lateral aspects of the chest. The hydraulic cushion transfers the circumferential constriction to inward force. CPR was performed on subjects 5 mins after induction of ventricular fibrillation, with the hydraulic-pneumatic band system (HB-CPR), with a pneumatic vest system (PV-CPR), and with standard manual CPR (S-CPR), each done for 2 mins in randomized order. Aortic and right atrial pressures were measured with micromanometers. Coronary perfusion pressure was calculated as the mean difference between the aortic and right atrial pressures during the release phase of chest compression. Aortic pressure and coronary perfusion pressure with HB-CPR and PV-CPR were improved over S-CPR, and HB-CPR produced comparable pressures to those of PV-CPR. The system for performing HB-CPR, however, was substantially lighter (10 vs. 50 kg) and consumed less energy (300 vs. 1000 watts) than that for PV-CPR. Thus, HB-CPR appears to produce a similar improvement in hemodynamics over S-CPR as PV-CPR but may be more portable than PV-CPR. Therefore, HB-CPR may allow larger scale testing of circumferential chest compression approaches.

  4. Pneumatic Muscle Actuated Rehabilitation Equipment of the Upper Limb Joints

    NASA Astrophysics Data System (ADS)

    Deaconescu dr. eng. habil., Andrea, Prof.

    2017-06-01

    Rehabilitation equipment of the upper limb joints holds a key role in passive physical therapy. Within this framework, the paper presents two such pieces of equipment developed for the rehabilitation of elbow and of wrist and knuckles, respectively. The presented and discussed equipment is actuated by pneumatic muscles, its benefits being a low cost, simple and robust construction, as well as short response time to commands.

  5. Comprehensive integration of homogeneous bioassays via centrifugo-pneumatic cascading.

    PubMed

    Godino, Neus; Gorkin, Robert; Linares, Ana V; Burger, Robert; Ducrée, Jens

    2013-02-21

    This work for the first time presents the full integration and automation concept for a range of bioassays leveraged by cascading a centrifugo-pneumatic valving scheme to sequentially move several liquids through shared channel segments for multi-step sample preparation into the detection zone. This novel centrifugo-pneumatic liquid handling significantly simplifies system manufacture by obviating the need for complex surface functionalization procedures or hybrid material integration, as it is common in conventional valving methods such as capillary burst valves or sacrificial valves. Based on the centrifugo-pneumatic valving scheme, this work presents a toolkit of operational elements implementing liquid loading/transfer, metering, mixing and sedimentation in a microstructured polymer disc. As a proof of concept for the broad class of homogeneous bioassays, the full integration and automation of a colorimetric nitrate/nitrite test for the detection of clinically relevant nitric oxide (NO) in whole blood is implemented. First, 40 μL of plasma is extracted from a 100 μL sample of human blood, incubated for one hour with the enzymatic mixture (60 μL), and finally reacted with 100 μL of colorimetric (Greiss) reagents. Following just a single loading phase at the beginning of the process, all of these steps are automated through the centrifugo-pneumatic cascade with a high level of flow control and synchronization. Our system shows good correlation with controls up to 50 μM of nitrate, which adequately covers the healthy human range (4 to 45.3 μM).

  6. Electric versus pneumatic power in hand prostheses for children.

    PubMed

    Plettenburg, D H

    1989-01-01

    Most externally powered hand prostheses for children with a unilateral congenital below-elbow amputation are myoelectrically controlled. All of them are electrically powered. Despite the success of fitting children with this kind of prostheses, there are some disadvantages: prosthetic weight is high, operating speed is low, the system is vulnerable and its size prohibits fitting it to patients with a long fore-arm stump. It will be shown that pneumatic power can overcome most of these disadvantages.

  7. Dynamic Analysis of Sounding Rocket Pneumatic System Revision

    NASA Technical Reports Server (NTRS)

    Armen, Jerald

    2010-01-01

    The recent fusion of decades of advancements in mathematical models, numerical algorithms and curve fitting techniques marked the beginning of a new era in the science of simulation. It is becoming indispensable to the study of rockets and aerospace analysis. In pneumatic system, which is the main focus of this paper, particular emphasis will be placed on the efforts of compressible flow in Attitude Control System of sounding rocket.

  8. Vibration and recoil control of pneumatic hammers. [by air flow pressure regulation

    NASA Technical Reports Server (NTRS)

    Constantinescu, I. N.; Darabont, A. V.

    1974-01-01

    Vibration sources are described for pneumatic hammers used in the mining industry (pick hammers), in boiler shops (riveting hammers), etc., bringing to light the fact that the principal vibration source is the variation in air pressure inside the cylinder. The present state of the art of vibration control of pneumatic hammers as it is practiced abroad, and the solutions adopted for this purpose, are discussed. A new type of pneumatic hammer with a low noise and vibration level is presented.

  9. Design and Control of a Pneumatically Actuated Transtibial Prosthesis

    PubMed Central

    Zheng, Hao; Shen, Xiangrong

    2015-01-01

    This paper presents the design and control of a pneumatically actuated transtibial prosthesis, which utilizes a pneumatic cylinder-type actuator to power the prosthetic ankle joint to support the user's locomotion. The pneumatic actuator has multiple advantages over the traditional electric motor, such as light weight, low cost, and high power-to-weight ratio. The objective of this work is to develop a compact and lightweight transtibial prosthesis, leveraging the multiple advantages provided by this highly competitive actuator. In this paper, the design details of the prosthesis are described, including the determination of performance specifications, the layout of the actuation mechanism, and the calculation of the torque capacity. Through the authors’ design calculation, the prosthesis is able to provide sufficient range of motion and torque capacity to support the locomotion of a 75 kg individual. The controller design is also described, including the underlying biomechanical analysis and the formulation of the finite-state impedance controller. Finally, the human subject testing results are presented, with the data indicating that the prosthesis is able to generate a natural walking gait and sufficient power output for its amputee user. PMID:26146497

  10. A Model-Based Prognostics Approach Applied to Pneumatic Valves

    NASA Technical Reports Server (NTRS)

    Daigle, Matthew J.; Goebel, Kai

    2011-01-01

    Within the area of systems health management, the task of prognostics centers on predicting when components will fail. Model-based prognostics exploits domain knowledge of the system, its components, and how they fail by casting the underlying physical phenomena in a physics-based model that is derived from first principles. Uncertainty cannot be avoided in prediction, therefore, algorithms are employed that help in managing these uncertainties. The particle filtering algorithm has become a popular choice for model-based prognostics due to its wide applicability, ease of implementation, and support for uncertainty management. We develop a general model-based prognostics methodology within a robust probabilistic framework using particle filters. As a case study, we consider a pneumatic valve from the Space Shuttle cryogenic refueling system. We develop a detailed physics-based model of the pneumatic valve, and perform comprehensive simulation experiments to illustrate our prognostics approach and evaluate its effectiveness and robustness. The approach is demonstrated using historical pneumatic valve data from the refueling system.

  11. Salivary Stone Pneumatic Lithotripsy in a Live Porcine Model.

    PubMed

    Walvekar, Rohan R; Hoffman, Henry T; Kolenda, Jack; Hernandez, Stephen

    2016-06-01

    The purpose of this study is to evaluate the efficacy of endoscopic fragmentation and removal of artificial calculi in a live porcine model employing intracorporeal pneumatic lithotripsy. In this experimental study, 7 submandibular ducts were accessed and artificial calculi placed. A salivary pneumatic lithotripter probe was inserted through an interventional sialendoscope to fragment the calculi. A salivary duct catheter was then used to flush stone fragments, followed by endoscopy to assess complete fragmentation and ductal trauma. Ultimately, 7 artificial stones (3-10 mm, 4F/5F) were successfully fragmented without causing significant endoluminal trauma. Number of pulses for adequate stone fragmentation averaged 20 (range, 5-31). In all cases, stone fragments were successfully flushed out with the salivary duct catheter. Postprocedure endoscopy confirmed ductal integrity in all 7 ducts. While more studies are needed, this preliminary animal model demonstrates efficacy of endoscopic pneumatic lithotripsy for the management of sialolithiasis. © American Academy of Otolaryngology—Head and Neck Surgery Foundation 2016.

  12. Evaluation of unsaturated zone air permeability through pneumatic tests

    USGS Publications Warehouse

    Baehr, Arthur L.; Hult, Marc F.

    1991-01-01

    Predicting the steady state distribution of air pressure in the unsaturated zone resulting from a pneumatic test provides a method for determining air-phase permeability. This technique is analogous to the inverse problem of well hydraulics; however, air flow is more complicated than ground water flow because of air compressibility, the Klinkenberg effect, variations in air density and viscosity that result from temperature fluctuations in the unsaturated zone and the possibility of inducing water movement during the pneumatic test. An analysis of these complicating factors reveals that, when induced water movement can be neglected, a linear version of the airflow equation can provide an appropriate approximation for the purpose of determining air-phase permeability. Two analytical solutions for steady state, two-dimensional, axisymmetric airflow to a single well partially screened in the unsaturated zone are developed. One solution applies where there is a stratum of relatively low air permeability, separating the stratum in which the well is completed, from the atmosphere. The other solution applies where there is no separating stratum between the domain and atmosphere. In both situations the water table forms the lower horizontal boundary. Applications of both solutions to determine air permeability from data collected during pneumatic tests are presented.

  13. Discussion on a Potential DJ Basin Pneumatic Controller ...

    EPA Pesticide Factsheets

    ORD NRMRL and Region 8 collaborators are conducting emission measurements and method development studies on pneumatic controllers (PCs) in the Uintah Basin, Utah (and potentially in Colorado), in cooperation with Oil and Natural gas (ONG) operators. ONG operations use PCs for production process control and safety functions. PCs emit gas to the atmosphere as they operate and sometimes they malfunction and emit more than they are supposed to. Because of the very large number of PCs in use, these devices contribute significantly to greenhouse gas (GHG) and volatile organic compound (VOC) emissions. There is considerable uncertainty in levels of real-world PC emissions and measurement methods for PCs are somewhat underdeveloped. In collaboration with EPA R8, the State of Colorado, (and industry participants in Step 2), ORD NRMRL is evaluating a potential follow-on research effort to the Uinta Basin Pneumatic Controller (PC) Study. The Uinta PC Study is described in a recent APPCD Research Highlight (attached )with results summarized in “Assessment of Uinta Basin Oil and Natural Gas Well Pad Pneumatic Controller Emissions”, E. Thoma et al., Journal of Environmental Protection, 8, 394-415, (2017). doi: 10.4236/jep.2017.84029; at (http://www.scirp.org/Journal/PaperInformation.aspx?PaperID=75669). This RAP research was funded by an EPA R8 RARE and ACE Task EM 1.2 (next gen. emissions measurements). For both technical and programmatic reasons, we seek to

  14. Design and control of a pneumatic musculoskeletal biped robot.

    PubMed

    Zang, Xizhe; Liu, Yixiang; Liu, Xinyu; Zhao, Jie

    2016-04-29

    Pneumatic artificial muscles are quite promising actuators for humanoid robots owing to their similar characteristics with human muscles. Moreover, biologically inspired musculoskeletal systems are particularly important for humanoid robots to perform versatile dynamic tasks. This study aims to develop a pneumatic musculoskeletal biped robot, and its controller, to realize human-like walking. According to the simplified musculoskeletal structure of human lower limbs, each leg of the biped robot is driven by nine muscles, including three pairs of monoarticular muscles which are arranged in the flexor-extensor form, as well as three biarticular muscles which span two joints. To lower cost, high-speed on/off solenoid valves rather than proportional valves are used to control the muscles. The joint trajectory tracking controller based on PID control method is designed to achieve the desired motion. Considering the complex characteristics of pneumatic artificial muscles, the control model is obtained through parameter identification experiments. Preliminary experimental results demonstrate that the biped robot is able to walk with this control strategy. The proposed musculoskeletal structure and control strategy are effective for the biped robot to achieve human-like walking.

  15. Effect of pneumatic compression on fibrinolysis after total hip arthroplasty.

    PubMed

    Macaulay, William; Westrich, Geoffrey; Sharrock, Nigel; Sculco, Thomas P; Jhon, Peter H; Peterson, Margaret G E; Salvati, Eduardo A

    2002-06-01

    The purpose of this prospective randomized clinical study was to investigate the enhanced systemic fibrinolysis mechanism of venous thrombosis prevention by pneumatic compression after total hip arthroplasty. Fifty patients were randomized into one of two groups (one with pneumatic compression [n=25] and one without [n=25]). Blood was drawn from a radial arterial line immediately preoperatively (baseline), at skin closure, and 8 hours and 22 hours after the baseline sample. Serum determinations of antigen of tissue plasminogen activator and plasminogen activator inhibitor-1 were done using enzyme-linked immunosorbent assays. These data do not support the enhancement of systemic fibrinolysis mechanism for lowering thromboembolic risk after total hip arthroplasty by pneumatic compression devices. The results of this study showed no differences that were statistically significant between the two groups. The greatest difference was observed 8 hours after surgery for the plasminogen activator inhibitor-1 marker, (28.12 with compression versus 22.07 ng/mL without); however, this result was not statistically significant. The beneficial effect of mechanical compression is more likely achieved through increased flow, local fibrinolytic effects, or both.

  16. A pneumatic orthotic cranial molding helmet for correcting positional plagiocephaly.

    PubMed

    Lee, Walter T; Richards, Kirsten; Redhed, James; Papay, Frank A

    2006-01-01

    The objective of this study was o determine the efficacy of a newly developed pneumatic orthotic cranial molding helmet for correcting positional plagiocephaly. The design was retrospective and the setting was a tertiary care center. Subjects were all patients in whom positional plagiocephaly has been diagnosed and who have been fitted by the Orthotics and Prosthetics Department for the helmet. Diagonal cranial lengths and widths were measured at each visit. Analysis included the calculation of the ratio change in oblique diameters compared with time, patient's age, and head circumference. Seventy-five patients met inclusion criteria (50 boys, 25 girls). Patients with pneumatic orthotic cranial molding helmet therapy had significantly improved outcomes as compared with pretreatment measurements (P < or = 0.0001). The helmet did not limit cranial growth as evidenced by significant normalization of the oblique measurement ratio when compared with increasing cranial circumference and age (P = 0.0003, P < or = 0.0001, respectively). The pneumatic orthotic cranial molding helmet successfully corrects positional plagiocephaly and does not hinder cranial growth.

  17. Formulation of a minimum variance deconvolution technique for compensation of pneumatic distortion in pressure sensing devices

    NASA Technical Reports Server (NTRS)

    Whitmore, Stephen A.

    1990-01-01

    Increasingly, aircraft system designs require that aerodynamic parameters derived from pneumatic measurements be employed as control-system feedbacks. Such high frequency pressure measurements' accuracy is compromised by pressure distortion due to frictional attenuation and pneumatic resonance within the sensing system. A pneumatic distortion model is here formulated and reduced to a low-order state-variable model which retains most of the full model's dynamic characteristics. This reduced-order model is coupled with standard results from minimum variance estimation theory to develop an algorithm to compensate for pneumatic-distortion effects.

  18. Formulation of a minimum variance deconvolution technique for compensation of pneumatic distortion in pressure sensing devices

    NASA Technical Reports Server (NTRS)

    Whitmore, Stephen A.

    1990-01-01

    Increasingly, aircraft system designs require that aerodynamic parameters derived from pneumatic measurements be employed as control-system feedbacks. Such high frequency pressure measurements' accuracy is compromised by pressure distortion due to frictional attenuation and pneumatic resonance within the sensing system. A pneumatic distortion model is here formulated and reduced to a low-order state-variable model which retains most of the full model's dynamic characteristics. This reduced-order model is coupled with standard results from minimum variance estimation theory to develop an algorithm to compensate for pneumatic-distortion effects.

  19. From rabbit antibody repertoires to rabbit monoclonal antibodies

    PubMed Central

    Weber, Justus; Peng, Haiyong; Rader, Christoph

    2017-01-01

    In this review, we explain why and how rabbit monoclonal antibodies have become outstanding reagents for laboratory research and increasingly for diagnostic and therapeutic applications. Starting with the unique ontogeny of rabbit B cells that affords highly distinctive antibody repertoires rich in in vivo pruned binders of high diversity, affinity and specificity, we describe the generation of rabbit monoclonal antibodies by hybridoma technology, phage display and alternative methods, along with an account of successful humanization strategies. PMID:28336958

  20. Clinical Effect of Endoscopic Pneumatic Dilation for Achalasia

    PubMed Central

    Cheng, Peng; Shi, Hai; Zhang, Yanjie; Zhou, Huabang; Dong, Jinhua; Cai, Yiting; Hu, Xing; Dai, Qiang; Yang, Wenyan

    2015-01-01

    Abstract Although pneumatic dilation is an accepted method for the treatment of achalasia, this therapy has high recurrence and complication rates, and prolonged follow-up studies on the parameters associated with various outcomes are rare. In this prospective 10-year follow-up study, a satisfactory therapeutic effect was achieved without serious complications. We report the therapeutic experience with pneumatic dilation, having aimed to evaluate the long-term clinical safety and efficacy of pneumatic dilation. In total, 35 consecutive patients with idiopathic achalasia who underwent pneumatic dilation were followed up at regular intervals in person or by a phone interview over a 10-year period. The mean duration of the follow-up was 43.03 ± 26.34 months (range 6–120 months). Remission was assessed by the dysphagia classification and symptom scores. Patients’ clinical symptom scores were calculated before and at 6 to 36 months, 37 to 60 months, and >60 months after therapy. The influence of the patients’ age, gender, and disease duration on the therapeutic effect was analyzed. The success rate of the operation was 97.2% (35/36), without massive hemorrhaging, perforation or other serious complications. Dysphagia after the therapy was significantly eased (P < 0.01). In total, 35 patients have been followed up for 6 to 36 months after therapy, 21 cases for 37 to 60 months, and 5 cases for >60 months, and the patients’ symptom scores separately decreased significantly compared with the pretherapy scores (P < 0.01). For these patients, the 6 to 36 months remission rate was 85.7% (30/35), the 37 to 60 months rate was 61.9% (13/21), and the >60 months rate was 40% (2/5). The dilation effect had no relationship to the patient's age, gender, and disease duration (P > 0.05). The patients in 30 cases (85.7%) were successfully treated with a single dilation, in 4 cases (11.4%) with 2 dilations, and in 1 case (2.9%) with 3 dilations

  1. Clinical Effect of Endoscopic Pneumatic Dilation for Achalasia.

    PubMed

    Cheng, Peng; Shi, Hai; Zhang, Yanjie; Zhou, Huabang; Dong, Jinhua; Cai, Yiting; Hu, Xing; Dai, Qiang; Yang, Wenyan

    2015-07-01

    Although pneumatic dilation is an accepted method for the treatment of achalasia, this therapy has high recurrence and complication rates, and prolonged follow-up studies on the parameters associated with various outcomes are rare. In this prospective 10-year follow-up study, a satisfactory therapeutic effect was achieved without serious complications. We report the therapeutic experience with pneumatic dilation, having aimed to evaluate the long-term clinical safety and efficacy of pneumatic dilation. In total, 35 consecutive patients with idiopathic achalasia who underwent pneumatic dilation were followed up at regular intervals in person or by a phone interview over a 10-year period. The mean duration of the follow-up was 43.03 ± 26.34 months (range 6-120 months). Remission was assessed by the dysphagia classification and symptom scores. Patients' clinical symptom scores were calculated before and at 6 to 36  months, 37 to 60  months, and >60  months after therapy. The influence of the patients' age, gender, and disease duration on the therapeutic effect was analyzed. The success rate of the operation was 97.2% (35/36), without massive hemorrhaging, perforation or other serious complications. Dysphagia after the therapy was significantly eased (P < 0.01). In total, 35 patients have been followed up for 6 to 36  months after therapy, 21 cases for 37 to 60  months, and 5 cases for >60  months, and the patients' symptom scores separately decreased significantly compared with the pretherapy scores (P < 0.01). For these patients, the 6 to 36  months remission rate was 85.7% (30/35), the 37 to 60  months rate was 61.9% (13/21), and the >60  months rate was 40% (2/5). The dilation effect had no relationship to the patient's age, gender, and disease duration (P > 0.05). The patients in 30 cases (85.7%) were successfully treated with a single dilation, in 4 cases (11.4%) with 2 dilations, and in 1 case (2.9%) with 3 dilations. These

  2. [Is pneumatic sample transport system also a carrier for microorganisms?].

    PubMed

    Alpat, Saygin Nayman; Ozgüneş, Ilhan; Aybey, Aşkin Derya; Ertem, Osman Turgut; Akşit, Filiz

    2009-07-01

    The purpose of this study was to evaluate the possible infection and contamination risk of the pneumatic system used in our hospital and to establish essential infection control measures. The study was conducted in a quaternary health care center with 1.000 bed capacity. A total of 614 specimens were taken 2 times weekly from the pneumatic transport system and its carriers at 22 wards, 5 intensive care units, 3 laboratories, 2 blood taking units, and pharmacy. Samples were also obtained from the fingertips of 33 subjects using the system, before and after contact with the carriers. A questionnaire that consisted of 8 questions was applied to 224 subjects who worked in those units, evaluating the degree of compliance to the obligations for the cleaning of the pneumatic system and carriers and their approach in case of visible pollution at the system. Bacterial growth was observed in 15.2% (45/296) of samples in the 1st week and 7.6% (18/238) of the samples in the 2nd week, making a total of 11.8% (63/534) bacterial growth. No growth was detected from the areas where the carriers were placed. Of these 69.8% were coagulase negative staphylococci, 11.1% diphteroids, 7.9% Acinetobacter Iwoffii, 4.8% Staphylococcus aureus, 4.8% Bacillus spp. and 1.6% Enterococcus durans. Acinetobacter baumannii and Aspergillus were detected at two fingertip samples taken before the contact with carriers, while again A. baumannii and Enterobacter cloacae were detected at the samples following contact. Moreover, 31.3% of the subjects noted that they cleaned the carriers only if any visible contamination was present. In addition, 14.3% reported that they have encountered broken or spilled up material in the system for more than 5 times, 10.3% reported that they followed the instructions in case of presence of infected material inside the carriers, 23.7% reported that they always washed their hands after any contact with the carriers, 9.8% noted that they always used gloves during contact

  3. The A-711 high yield neutron generator and automated pneumatic transfer system for fast neutron activation analysis

    NASA Astrophysics Data System (ADS)

    Simpson, James D.; Chichester, D. L.; Hill, J. R.

    2005-12-01

    To make fast neutron activation analysis (FNAA) of samples with short half-lives easier, Thermo Electron has updated and modernized its automatic pneumatic transfer system for activation laboratories. For example, with a separation of 10 m from the counting station and a transit speed of 15 m/s, oxygen can be analyzed with improved accuracy. The fast transit time is needed due to the short half-lives of 16N and 19O, 7 s and 27 s respectively, and oxygen-free polyethylene sample bottles are used to allow prompt counting and decrease background counts. Incorporating a dual-axis rotator at the irradiation station for sample and standard, the transfer system also incorporates stations for sample loading, disposal and counting as well as a station to incorporate a chemical neutron source such as Cf-252.

  4. Rabbits killing birds revisited.

    PubMed

    Zhang, Jimin; Fan, Meng; Kuang, Yang

    2006-09-01

    We formulate and study a three-species population model consisting of an endemic prey (bird), an alien prey (rabbit) and an alien predator (cat). Our model overcomes several model construction problems in existing models. Moreover, our model generates richer, more reasonable and realistic dynamics. We explore the possible control strategies to save or restore the bird by controlling or eliminating the rabbit or the cat when the bird is endangered. We confirm the existence of the hyperpredation phenomenon, which is a big potential threat to most endemic prey. Specifically, we show that, in an endemic prey-alien prey-alien predator system, eradication of introduced predators such as the cat alone is not always the best solution to protect endemic insular prey since predator control may fail to protect the indigenous prey when the control of the introduced prey is not carried out simultaneously.

  5. Rabbit renotropic system

    SciTech Connect

    Areas, J.; Yun, G.C.; Rahmat, J.; Gersten, D.; Goel, R.; Preuss, H.G.

    1988-04-01

    Elevated levels of a specific renal growth factor, renotropin, have been associated with spontaneous hypertension. To examine this association more closely, we have undertaken the development of a better assay system to characterize and purify renotropin. Sera from rabbits prior to operation (control) and at a specified time after unilateral nephrectomy (uni) were examined for renotropic activity. Comparing the effects of uni to control sera in the same rabbit, significant stimulation of 3H-thymidine incorporation into the DNA of primary rabbit kidney cultures incubated in D-valine medium to eliminate fibroblast growth was noted: at 3 days postoperatively 73% (n = 13), at 7 days 103% (n = 39), at 10 days 130% (n = 31), at 21 days 101% (n = 24), at 42 days 89% (n = 13). All values were at least P less than 0.01. The stimulatory properties were dose-dependent but reached a plateau at high serum concentrations. Comparing CPM/mg protein in uni/control in different concentrations of sera 7 days postoperatively, uni versus control were 67/44 at 5% v/v, 139/72 at 10% v/v, 261/161 at 20% v/v, and 243/136 at 40% v/v. The renotropic effect of uni sera remained after dialysis in incubation medium and after sera were heated in boiling water for 5 minutes. Renal extracts obtained from growing kidneys 7 days postnephrectomy augmented renotropic activity. Atrial natriuretic factor, ouabain, PGF2 alpha, PGE1, and cAMP did not possess renotropic activity. We conclude that the primary rabbit kidney culture assay for renotropin is highly sensitive and will be an important tool to comprehend the role of renotropin in the pathogenesis of hypertension.

  6. Pulmonary pneumaticity in the postcranial skeleton of extant aves: a case study examining Anseriformes.

    PubMed

    O'Connor, Patrick M

    2004-08-01

    Anseriform birds were surveyed to examine how the degree of postcranial pneumaticity varies in a behaviorally and size-diverse clade of living birds. This study attempts to extricate the relative effects of phylogeny, body size, and behavioral specializations (e.g., diving, soaring) that have been postulated to influence the extent of postcranial skeletal pneumaticity. One hundred anseriform species were examined as the focal study group. Methods included latex injection of the pulmonary apparatus followed by gross dissection or direct examination of osteological specimens. The Pneumaticity Index (PI) is introduced as a means of quantifying and comparing postcranial pneumaticity in a number of species simultaneously. Phylogenetically independent contrasts (PICs) were used to examine the relationship between body size and the degree of postcranial pneumaticity throughout the clade. There is a high degree of similarity (i.e., clade-specificity) within most anseriform subgroups. As a whole, Anseriformes demonstrate no significant relationship between relative pneumaticity and body size, as indicated by regression analysis of body mass on PI. It is apparent, however, that many clades of diving ducks do exhibit lower PIs than their nondiving relatives. By exclusion of diving taxa from analyses, a significant positive slope is observed and the hypothesis of relatively higher pneumaticity in larger-bodied birds is only weakly supported. However, low correlations indicate that factors other than body size account for much of the variation observed in relative pneumaticity. Pneumaticity profiles were mapped onto existing phylogenetic hypotheses. A reduction in the degree of postcranial pneumaticity occurred independently in at least three anseriform subclades specialized for diving. Finally, enigmatic pneumatic features located in distal forelimb elements of screamers (Anhimidae) result from invasion of bone by a network of subcutaneous air sac diverticula spreading

  7. Release of Pro-Aggregation Substances from Rabbit Leukocytes Exposed to UV Light: Role of Photo-Induced Apoptosis.

    PubMed

    Anosov, A K; Gorbach, M M

    2015-12-01

    Accumulation of pro-aggregation substances in the incubation medium of isolated UV-irradiated rabbit leukocytes showed stronger correlation with photo-induced apoptotic death of leukocytes (r=0.92) than with their photo-induced necrotic death (r=0.70). It can be suggested that pro-aggregation substances release form leukocytes exposed to irradiation during preparation of these cells to apoptosis after UV irradiation.

  8. 49 CFR 571.117 - Standard No. 117; Retreaded pneumatic tires.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... HIGHWAY TRAFFIC SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION FEDERAL MOTOR VEHICLE SAFETY STANDARDS Federal Motor Vehicle Safety Standards § 571.117 Standard No. 117; Retreaded pneumatic tires. S1. Scope... passenger car tires. S2. Purpose. The purpose of this standard is to require retreaded pneumatic...

  9. A quantitative method for the evaluation of three-dimensional structure of temporal bone pneumatization

    PubMed Central

    Hill, Cheryl A.; Richtsmeier, Joan T.

    2010-01-01

    Temporal bone pneumatization has been included in lists of characters used in phylogenetic analyses of human evolution. While studies suggest that the extent of pneumatization has decreased over the course of human evolution, little is known about the processes underlying these changes or their significance. In short, reasons for the observed reduction and the potential reorganization within pneumatized spaces are unknown. Technological limitations have limited previous analyses of pneumatization in extant and fossil species to qualitative observations of the extent of temporal bone pneumatization. In this paper, we introduce a novel application of quantitative methods developed for the study of trabecular bone to the analysis of pneumatized spaces of the temporal bone. This method utilizes high-resolution X-ray computed tomography (HRXCT) images and quantitative software to estimate three-dimensional parameters (bone volume fractions, anisotropy, and trabecular thickness) of bone structure within defined units of pneumatized spaces. We apply this approach in an analysis of temporal bones of diverse but related primate species, Gorilla gorilla, Pan troglodytes, Homo sapiens, and Papio hamadryas anubis, to illustrate the potential of these methods. In demonstrating the utility of these methods, we show that there are interspecific differences in the bone structure of pneumatized spaces, perhaps reflecting changes in the localized growth dynamics, location of muscle attachments, encephalization, or basicranial flexion. PMID:18715622

  10. 78 FR 3843 - Federal Motor Vehicle Safety Standards; New Pneumatic and Certain Specialty Tires

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-01-17

    ... National Highway Traffic Safety Administration 49 CFR Part 571 RIN 2127-AK42 Federal Motor Vehicle Safety... Motor Vehicle Safety Standard (FMVSS) No. 109, New pneumatic and certain specialty tires, to change the... Pneumatic Tyres For Passenger-Use Motor Vehicles, Annex, 1-2-5. We believed that existing 60-psi T-type...

  11. 21 CFR 874.4250 - Ear, nose, and throat electric or pneumatic surgical drill.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... surgical drill. 874.4250 Section 874.4250 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH....4250 Ear, nose, and throat electric or pneumatic surgical drill. (a) Identification. An ear, nose, and throat electric or pneumatic surgical drill is a rotating drilling device, including the handpiece, that...

  12. His majesty's subjects: from laboratory to human experiment in pneumatic chemistry.

    PubMed

    Stewart, Larry

    2009-09-20

    Experiments in pneumatic chemistry paved the way for medical innovation in the last quarter of the eighteenth century. Thomas Beddoes and James Watt were instrumental in the spread of the use of new gas chemistry in pneumatic therapy, but they were far from alone. There was no shortage of experimental subjects, as the practice was quickly taken up by medics throughout Britain.

  13. 46 CFR 108.409 - Location and spacing of tubing in pneumatic fire detection system.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... detection system. 108.409 Section 108.409 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS DESIGN AND EQUIPMENT Fire Extinguishing Systems § 108.409 Location and spacing of tubing in pneumatic fire detection system. (a) All tubing in a pneumatic fire...

  14. 46 CFR 128.240 - Hydraulic or pneumatic power and control-materials and pressure design.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 4 2011-10-01 2011-10-01 false Hydraulic or pneumatic power and control-materials and...) OFFSHORE SUPPLY VESSELS MARINE ENGINEERING: EQUIPMENT AND SYSTEMS Materials and Pressure Design § 128.240 Hydraulic or pneumatic power and control—materials and pressure design. (a) Each standard piping...

  15. 46 CFR 54.10-15 - Pneumatic test (modifies UG-100).

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... testing of welded pressure vessels shall be permitted only for those units which are so designed and/or...) Except for enameled vessels, for which the pneumatic test pressure shall be at least equal to, but need not exceed, the maximum allowable working pressure to be marked on the vessel, the pneumatic test...

  16. 40 CFR 60.253 - Standards for pneumatic coal-cleaning equipment.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 6 2010-07-01 2010-07-01 false Standards for pneumatic coal-cleaning... PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Coal Preparation and Processing Plants § 60.253 Standards for pneumatic coal-cleaning equipment. (a) On and...

  17. 49 CFR 571.129 - Standard No. 129; New non-pneumatic tires for passenger cars.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... passenger cars. 571.129 Section 571.129 Transportation Other Regulations Relating to Transportation...-pneumatic tires for passenger cars. S1Scope. This standard specifies tire dimensions and laboratory test... applies to new temporary spare non-pneumatic tires for use on passenger cars. S3Definitions. Carcass...

  18. 49 CFR 571.129 - Standard No. 129; New non-pneumatic tires for passenger cars.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... passenger cars. 571.129 Section 571.129 Transportation Other Regulations Relating to Transportation...-pneumatic tires for passenger cars. S1Scope. This standard specifies tire dimensions and laboratory test... applies to new temporary spare non-pneumatic tires for use on passenger cars. S3Definitions. Carcass...

  19. 49 CFR 571.129 - Standard No. 129; New non-pneumatic tires for passenger cars.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... passenger cars. 571.129 Section 571.129 Transportation Other Regulations Relating to Transportation...-pneumatic tires for passenger cars. S1Scope. This standard specifies tire dimensions and laboratory test... applies to new temporary spare non-pneumatic tires for use on passenger cars. S3Definitions. Carcass...

  20. 49 CFR 571.129 - Standard No. 129; New non-pneumatic tires for passenger cars.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... passenger cars. 571.129 Section 571.129 Transportation Other Regulations Relating to Transportation...-pneumatic tires for passenger cars. S1Scope. This standard specifies tire dimensions and laboratory test... applies to new temporary spare non-pneumatic tires for use on passenger cars. S3Definitions. Carcass...

  1. 21 CFR 874.4250 - Ear, nose, and throat electric or pneumatic surgical drill.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Ear, nose, and throat electric or pneumatic... AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES EAR, NOSE, AND THROAT DEVICES Surgical Devices § 874.4250 Ear, nose, and throat electric or pneumatic surgical drill. (a) Identification. An ear, nose,...

  2. 21 CFR 874.4250 - Ear, nose, and throat electric or pneumatic surgical drill.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Ear, nose, and throat electric or pneumatic... AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES EAR, NOSE, AND THROAT DEVICES Surgical Devices § 874.4250 Ear, nose, and throat electric or pneumatic surgical drill. (a) Identification. An ear, nose,...

  3. 21 CFR 874.4250 - Ear, nose, and throat electric or pneumatic surgical drill.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Ear, nose, and throat electric or pneumatic... AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES EAR, NOSE, AND THROAT DEVICES Surgical Devices § 874.4250 Ear, nose, and throat electric or pneumatic surgical drill. (a) Identification. An ear, nose,...

  4. 76 FR 14906 - Certain New Pneumatic Off-the-Road Tires From the People's Republic of China: Notice of Extension...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-03-18

    ... International Trade Administration Certain New Pneumatic Off-the-Road Tires From the People's Republic of China... pneumatic off-the-road tires (``OTR tires'') from the People's Republic of China (``PRC'') for the period... on OTR tires from the PRC. See Certain New Pneumatic Off-the-Road Tires From the People's Republic of...

  5. 78 FR 33059 - Certain New Pneumatic Off-the-Road Tires From the People's Republic of China: Rescission of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-06-03

    ... International Trade Administration Certain New Pneumatic Off-the-Road Tires From the People's Republic of China...'' of the antidumping duty order on certain new pneumatic off-the-road tires from the People's Republic... administrative review of the antidumping duty order on certain new pneumatic off-the-road tires, with respect to...

  6. 77 FR 10476 - Certain New Pneumatic Off-the-Road Tires From the People's Republic of China: Notice of Second...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-02-22

    ... International Trade Administration Certain New Pneumatic Off-the-Road Tires From the People's Republic of China... the administrative review of the antidumping duty order on certain new pneumatic off-the-road tires... New Pneumatic Off-the-Road Tires from the People's Republic of China: Preliminary Results of the 2009...

  7. 76 FR 6603 - Certain New Pneumatic Off-the-Road Tires From the People's Republic of China: Notice of Extension...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-02-07

    ... International Trade Administration Certain New Pneumatic Off-the-Road Tires From the People's Republic of China... pneumatic off-the-road tires (``OTR tires'') from the People's Republic of China (``PRC'') for the period... on OTR tires from the PRC. See Certain New Pneumatic Off-the-Road Tires From the People's Republic of...

  8. 77 FR 26508 - Certain New Pneumatic Off-the-Road Tires From the People's Republic of China: Initiation of New...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-05-04

    ... International Trade Administration Certain New Pneumatic Off-the-Road Tires From the People's Republic of China... determined that a request for a new shipper review of the antidumping duty order on certain new pneumatic off... shipper review.\\5\\ \\1\\ See Certain New Pneumatic Off-the-Road Tires From the People's Republic of China...

  9. 76 FR 31584 - Certain New Pneumatic Off-the-Road Tires From the People's Republic of China: Extension of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-06-01

    ... International Trade Administration Certain New Pneumatic Off-the-Road Tires From the People's Republic of China... new pneumatic off-the-road tires from the People's Republic of China (``PRC''). This review covers the... administrative review of the antidumping duty order on certain new pneumatic off-the-road tires from the PRC. See...

  10. 77 FR 6536 - Certain New Pneumatic Off-the-Road Tires From the People's Republic of China: Notice of Extension...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-02-08

    ... International Trade Administration Certain New Pneumatic Off-the-Road Tires From the People's Republic of China... administrative review of the antidumping duty order on certain new pneumatic off-the-road tires (``off-the-road... administrative review of the antidumping order on off- the-road tires from the PRC. See Certain New Pneumatic Off...

  11. 75 FR 62504 - Certain New Pneumatic Off-the-Road Tires From the People's Republic of China: Notice of Decision...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-10-12

    ... International Trade Administration Certain New Pneumatic Off-the-Road Tires From the People's Republic of China... investigation on certain new pneumatic off-the-road tires (``OTR tires'') from the People's Republic of China...''). See Certain New Pneumatic Off-The-Road-Tires from the People's Republic of China: Final Affirmative...

  12. [Pneumatic dilatation of achalasia: local experience in treating 41 patients].

    PubMed

    Honein, Khalil; Slim, Rita; Yaghi, César; Kheir, Bahaa; Bou Jaoudé, Joseph; Sayegh, Raymond

    2007-01-01

    L'achalasia is the best known primary motor disorder of the esophagus in which the lower esophageal sphincter (LES) has abnormally high resting pressure and incomplete relaxation with swallowing. Pneumatic dilatation (PD) remains the first choice of treatment. Our aim was to report, in a retrospective way, our experience in treating with pneumatic dilatation 41 achalasia patients admitted to the gastroenterology unit at Hôtel-Dieu de France (HDF) hospital between 1994 and 2004. A total of 46 dilatations were performed in 41 patients with achalasia [20 males and 21 females, the mean age was 46.8 years (range, 15-90)]. All patients underwent an initial dilatation by inflating a 35 mm balloon to 7 psi three times successively under fluoroscopic control. The need for subsequent dilatation with the same technique or for surgical treatment was based on symptom assessment. The mean follow-up period was 36.7 months (3 mo-7 years). Among the patients whose follow-up information was available, a satisfactory result was achieved in 29 patients (80.5%) after only one or two sessions of pneumatic dilatation. Esophageal perforation as a short-term complication was observed in one patient (2.17%). Seven patients were referred for surgery (one for esophageal perforation and six for persistent or recurrent symptoms). In conclusion, performing balloon dilatation under fluoroscopic observation is simple, safe and efficacious for treating patients with achalasia. Referral to repeated PD or to surgical myotomy should be discussed in case of no response to a first session of PD.

  13. Muscle- and pneumatic-powered counterpulsating LVADs: a pilot study.

    PubMed

    Wilde, J C; van Loon, J; Bishop, N D; Shelton, A D; Marten, C; Kolff, W J; Stephenson, L; Baciewicz, F; Nakajima, H; Thomas, G

    1994-03-01

    There is a worldwide interest in supporting the failing heart with a skeletal muscle by either wrapping it around the natural heart (dynamic cardiomyoplasty) or by constructing a skeletal muscle ventricle (SMV) used for counterpulsation. Conventional cardiomyoplasty in many clinics carries an operative mortality rate of 15-20% partly because it requires 6 weeks to train the muscle to contract continually. A flexible, pear-shaped blood pump with an inflatable air chamber was designed and made around which a muscle can be wrapped. The advantage of our design is that it can also be driven by pneumatic power, immediately supporting the circulation of a seriously ill patient while that patient is still on the operating table. After a period of time to allow for revascularization and the subsequent training of the muscle, the external pneumatic power can be gradually discontinued. Then the assisted patient becomes tether-free. If, at any time, the muscle power fails, the pneumatic-powered mechanism can be reactivated. In the preferred approach, the blood pump is connected to the aorta for diastolic counterpulsation. A muscle can either be wrapped around the blood pump directly, or around one of two separate muscle pouches connected to the blood pump. To facilitate surgery, a large pouch is inserted under the musculus latissimus dorsi, which is connected to a blood pump. When stimulated, the muscle will contract over the pouch compressing it and providing power to the blood pump. If it is found that the pressure generated in the pouch cannot meet the aortic blood pressure, it can be augmented by using a pressure amplifier.(ABSTRACT TRUNCATED AT 250 WORDS)

  14. Computed tomography of temporal bone pneumatization. 1. Normal pattern and morphology

    SciTech Connect

    Virapongse, C.; Sarwar, M.; Bhimani, S.; Sasaki, C.; Shapiro, R.

    1985-09-01

    The pneumatization of 141 normal temporal bones on computed tomography (CT) was evaluated in 100 patients. Because of the controversy surrounding the sclerotic squamomastoid (mastoid), temporal bones with this finding were discarded. A CT index of pneumatization was based on the pneumatized area and the number of cells seen within a representative scanning section. Results suggest that squamomastoid pneumatization follows the classic normal distribution and does not correlate with age, gender, or laterality. A high degree of symmetry was found in 41 patients who had both ears examined. Air-cell configuration was variable. Air-cell size tended to increase progressively from the mastoid antrum. The scutum pseudotumor appearance caused by incomplete pneumatization was seen frequently, and should not be mistaken for mastoiditis or an osteoma. Thick sections producing partial-volume effect may also produce this spurious finding. Therefore, when searching for mucosal thickening due to mastoiditis, large air cells should preferably be analyzed.

  15. Compact, Non-Pneumatic Rock-Powder Samplers

    NASA Technical Reports Server (NTRS)

    Sherrit, Stewart; Bar-Cohen, Yoseph; Badescu, Mircea; Bao, Xiaoqi; Chang, Zensheu; Jones, Christopher; Aldrich, Jack

    2008-01-01

    Tool bits that automatically collect powdered rock, permafrost, or other hard material generated in repeated hammering action have been invented. The present invention pertains to the special case in which it is desired to collect samples in powder form for analysis by x-ray diffraction and possibly other techniques. The present invention eliminates the need for both the mechanical collection equipment and the crushing chamber and the pneumatic collection equipment of prior approaches, so that it becomes possible to make the overall sample-acquisition apparatus more compact.

  16. PNEUMATIC MICROVALVE FOR ELECTROKINETIC SAMPLE PRECONCENTRATION AND CAPILLARY ELECTROPHORESIS INJECTION

    SciTech Connect

    Cong, Yongzheng; Rausch, Sarah J.; Geng, Tao; Jambovane, Sachin R.; Kelly, Ryan T.

    2014-10-27

    Here we show that a closed pneumatic microvalve on a PDMS chip can serve as a semipermeable membrane under an applied potential, enabling current to pass through while blocking the passage of charged analytes. Enrichment of both anionic and cationic species has been demonstrated, and concentration factors of ~70 have been achieved in just 8 s. Once analytes are concentrated, the valve is briefly opened and the sample is hydrodynamically injected onto an integrated microchip or capillary electrophoresis (CE) column. In contrast to existing preconcentration approaches, the membrane-based method described here enables both rapid analyte concentration as well as high resolution separations.

  17. Model free control for differential pneumatic pistons: experimental comparison

    NASA Astrophysics Data System (ADS)

    Weist, Jens; Arteaga, Marco A.; de la Cruz, Leonardo R.; Hebisch, Holger

    2011-01-01

    PID controllers are widely used in industry. While this may be appropriate for many systems, eventually a more complex or reliable algorithm has to be designed to improve performance. Common praxis is to take advantage either of physical properties (e.g. passivity) or of a mathematical model. For this last case it may prove to be hard to get an accurate description of the system dynamics. In this article we experimentally analyse the behaviour of pneumatic actuators by employing control algorithms available in the literature with little or no model information at all, including an adaptation of a robot control law which is shown to work very well for the test bed.

  18. Comparison of contractile and extensile pneumatic artificial muscles

    NASA Astrophysics Data System (ADS)

    Pillsbury, Thomas E.; Wereley, Norman M.; Guan, Qinghua

    2017-09-01

    Pneumatic artificial muscles (PAMs) are used in robotic and prosthetic applications due to their high power to weight ratio, controllable compliance, and simple design. Contractile PAMs are typically used in traditional hard robotics in place of heavy electric motors. As the field of soft robotics grows, extensile PAMs are beginning to have increased usage. This work experimentally tests, models, and compares contractile and extensile PAMs to demonstrate the advantages and disadvantages of each type of PAM and applications for which they are best suited.

  19. INFECTIOUS MYXOMATOSIS OF RABBITS

    PubMed Central

    Rivers, T. M.

    1930-01-01

    The virus of infectious myxomatosis of rabbits (Sanarelli) induces multiple lesions in the skin, lymph glands, tunica vaginalis,epididymis, testicle, spleen, and lungs. Growth and destruction of cells in the epidermis overlying the myxomatous masses leads to the formation of vesicles. Cytoplasmic inclusions are found in affected epidermal cells. Occasionally, similar inclusions are seen in other involved epithelial cells. The nature of the inclusions is an open question. In the myxomatous masses situated in the subcutaneous and other tissues, evidences of alteration and growth of certain cells are observed. PMID:19869741

  20. INFECTIOUS MYXOMATOSIS OF RABBITS

    PubMed Central

    Smadel, Joseph E.; Ward, S. M.; Rivers, Thomas M.

    1940-01-01

    A second soluble antigen, separable from the virus, occurs in extracts of infected skin and in the serum of rabbits acutely ill with infectious myxomatosis. Like the first antigen (A), the second (B) is heat labile and has certain characteristics of a globulin. The two antigens precipitate in different concentrations of ammonium sulfate and can be separated by this method. Neither of the antigens after being heated at 56°C. precipitates in the presence of specific antibody but each is capable of inhibiting the activity of its antibody. PMID:19871012

  1. Use and teaching of pneumatic otoscopy in a family medicine residency program.

    PubMed

    Ouedraogo, Eva; Labrecque, Michel; Côté, Luc; Charbonneau, Katerine; Légaré, France

    2013-09-01

    To determine to what extent FPs teach and use pneumatic otoscopy and to identify the chief influences on this behaviour. Mixed-methods descriptive study conducted between March and May 2011. The family medicine residency program at Laval University in Quebec city, Que. Directors of the family medicine teaching units (FMTUs), teachers, and residents. We used questionnaires to assess the availability of pneumatic otoscopy equipment in 12 FMTUs, current behaviour and behavioural intention among physicians (residents and teachers) to use or teach pneumatic otoscopy, and facilitators and barriers to these practices. We also conducted 2 focus groups to further explore the facilitators of and barriers to using pneumatic otoscopy. We used descriptive statistics for quantitative data, transcribed the qualitative material, and performed content analysis. Eight of the 12 FMTUs reported having pneumatic otoscopy equipment. Four had it in all of their consulting rooms, and 2 formally taught it. Nine (4%) of 211 physicians reported regular use of pneumatic otoscopy. Mean (SD) intention to teach or use pneumatic otoscopy during the next year was low (2.4 [1.0] out of 5). Teachers identified improved diagnostic accuracy as the main facilitator both for use and for teaching, while residents identified recommendation by practice guidelines as the main facilitator for use. All physicians reported lack of availability of equipment as the main barrier to use. The main barrier to teaching pneumatic otoscopy reported by teachers was that they did not use it themselves. In focus groups, themes of consequences, capabilities, and socioprofessional influences were most dominant. Residents clearly identified role modeling by teachers as facilitating the use of pneumatic otoscopy. Pneumatic otoscopy is minimally used and taught in the family medicine residency program studied. Interventions to increase its use should target identified underlying beliefs and facilitators of and barriers to its

  2. Use and teaching of pneumatic otoscopy in a family medicine residency program

    PubMed Central

    Ouedraogo, Eva; Labrecque, Michel; Côté, Luc; Charbonneau, Katerine; Légaré, France

    2013-01-01

    Abstract Objective To determine to what extent FPs teach and use pneumatic otoscopy and to identify the chief influences on this behaviour. Design Mixed-methods descriptive study conducted between March and May 2011. Setting The family medicine residency program at Laval University in Quebec city, Que. Participants Directors of the family medicine teaching units (FMTUs), teachers, and residents. Methods We used questionnaires to assess the availability of pneumatic otoscopy equipment in 12 FMTUs, current behaviour and behavioural intention among physicians (residents and teachers) to use or teach pneumatic otoscopy, and facilitators and barriers to these practices. We also conducted 2 focus groups to further explore the facilitators of and barriers to using pneumatic otoscopy. We used descriptive statistics for quantitative data, transcribed the qualitative material, and performed content analysis. Main findings Eight of the 12 FMTUs reported having pneumatic otoscopy equipment. Four had it in all of their consulting rooms, and 2 formally taught it. Nine (4%) of 211 physicians reported regular use of pneumatic otoscopy. Mean (SD) intention to teach or use pneumatic otoscopy during the next year was low (2.4 [1.0] out of 5). Teachers identified improved diagnostic accuracy as the main facilitator both for use and for teaching, while residents identified recommendation by practice guidelines as the main facilitator for use. All physicians reported lack of availability of equipment as the main barrier to use. The main barrier to teaching pneumatic otoscopy reported by teachers was that they did not use it themselves. In focus groups, themes of consequences, capabilities, and socioprofessional influences were most dominant. Residents clearly identified role modeling by teachers as facilitating the use of pneumatic otoscopy. Conclusion Pneumatic otoscopy is minimally used and taught in the family medicine residency program studied. Interventions to increase its use

  3. Real gas effects on charging and discharging processes of high pressure pneumatics

    NASA Astrophysics Data System (ADS)

    Luo, Yuxi; Wang, Xuanyin; Ge, Yaozheng

    2013-01-01

    The high pressure pneumatic system has been applied to special industries. It may cause errors when we analyze high pressure pneumatics under ideal gas assumption. However, the real gas effect on the performances of high pressure pneumatics is seldom investigated. In this paper, the real gas effects on air enthalpy and internal energy are estimated firstly to study the real gas effect on the energy conversion. Under ideal gas assumption, enthalpy and internal energy are solely related to air temperature. The estimation result indicates that the pressure enthalpy and pressure internal energy of real pneumatic air obviously decrease the values of enthalpy and internal energy for high pressure pneumatics, and the values of pressure enthalpy and pressure internal energy are close. Based on the relationship among pressure, enthalpy and internal energy, the real gas effects on charging and discharging processes of high pressure pneumatics are estimated, which indicates that the real gas effect accelerates the temperature and pressure decreasing rates during discharging process, and decelerates their increasing rates during charging process. According to the above analysis, and for the inconvenience in building the simulation model for real gas and the difficulty of measuring the detail thermal capacities of pneumatics, a method to compensate the real gas effect under ideal gas assumption is proposed by modulating the thermal capacity of the pneumatic container in simulation. The experiments of switching expansion reduction (SER) for high pressure pneumatics are used to verify this compensating method. SER includes the discharging process of supply tanks and the charging process of expansion tank. The simulated and experimental results of SER are highly consistent. The proposed compensation method provides a convenient way to obtain more realistic simulation results for high pressure pneumatics.

  4. Tissue irradiator

    DOEpatents

    Hungate, F.P.; Riemath, W.F.; Bunnell, L.R.

    1975-12-16

    A tissue irradiator is provided for the in-vivo irradiation of body tissue. The irradiator comprises a radiation source material contained and completely encapsulated within vitreous carbon. An embodiment for use as an in- vivo blood irradiator comprises a cylindrical body having an axial bore therethrough. A radioisotope is contained within a first portion of vitreous carbon cylindrically surrounding the axial bore, and a containment portion of vitreous carbon surrounds the radioisotope containing portion, the two portions of vitreous carbon being integrally formed as a single unit. Connecting means are provided at each end of the cylindrical body to permit connections to blood- carrying vessels and to provide for passage of blood through the bore. In a preferred embodiment, the radioisotope is thulium-170 which is present in the irradiator in the form of thulium oxide. A method of producing the preferred blood irradiator is also provided, whereby nonradioactive thulium-169 is dispersed within a polyfurfuryl alcohol resin which is carbonized and fired to form the integral vitreous carbon body and the device is activated by neutron bombardment of the thulium-169 to produce the beta-emitting thulium-170.

  5. [Food irradiation].

    PubMed

    Migdał, W

    1995-01-01

    A worldwide standard on food irradiation was adopted in 1983 by Codex Alimentarius Commission of the Joint Food Standard Programme of the Food and Agriculture Organization (FAO) of the United Nations and the World Health Organization (WHO). As a result, 41 countries have approved the use of irradiation for treating one or more food items and the number is increasing. Generally, irradiation is used to: food loses, food spoilage, disinfestation, safety and hygiene. The number of countries which use irradiation for processing food for commercial purposes has been increasing steadily from 19 in 1987 to 33 today. In the frames of the national programme on the application of irradiation for food preservation and hygienization an experimental plant for electron beam processing has been established in Institute of Nuclear Chemistry and Technology. The plant is equipped with a small research accelerator Pilot (19MeV, 1 kW) and an industrial unit Elektronika (10MeV, 10 kW). On the basis of the research there were performed at different scientific institutions in Poland, health authorities have issued permission for irradiation for: spices, garlic, onions, mushrooms, potatoes, dry mushrooms and vegetables.

  6. Study of the effects of semiconductor laser irradiation on peripheral nerve injury

    NASA Astrophysics Data System (ADS)

    Xiong, G. X.; Li, P.

    2012-11-01

    In order to study to what extent diode laser irradiation effects peripheral nerve injury, the experimental research was made on rabbits. Experimental results show that low-energy semiconductor laser can promote axonal regeneration and improve nervous function. It is also found that simultaneous exposure of the injured peripheral nerve and corresponding spinal segments to laser irradiation may achieve the most significant results.

  7. [Functional alterations in the retina following a 10 Gy gamma irradiation localized in the eye].

    PubMed

    Bagot, J D; Courant, D; Court, L

    1980-11-17

    A single-eye irradiation of 10 Gy (0.8 Gy. min-1) induces impairments of the electrical responses of the rabbit retina in dark adaptation. These are associated with reversible alteration of the photoreceptors and the preganglionic neurons and a disturbance of all the mechanisms of adaptation. Possible relationships between these functional alterations and the effects of irradiation are discussed.

  8. Prognostics for Ground Support Systems: Case Study on Pneumatic Valves

    NASA Technical Reports Server (NTRS)

    Daigle, Matthew; Goebel, Kai

    2011-01-01

    Prognostics technologies determine the health (or damage) state of a component or sub-system, and make end of life (EOL) and remaining useful life (RUL) predictions. Such information enables system operators to make informed maintenance decisions and streamline operational and mission-level activities. We develop a model-based prognostics methodology for pneumatic valves used in ground support equipment for cryogenic propellant loading operations. These valves are used to control the flow of propellant, so failures may have a significant impact on launch availability. Therefore, correctly predicting when valves will fail enables timely maintenance that avoids launch delays and aborts. The approach utilizes mathematical models describing the underlying physics of valve degradation, and, employing the particle filtering algorithm for joint state-parameter estimation, determines the health state of the valve and the rate of damage progression, from which EOL and RUL predictions are made. We develop a prototype user interface for valve prognostics, and demonstrate the prognostics approach using historical pneumatic valve data from the Space Shuttle refueling system.

  9. Independence of biomechanical forces and craniofacial pneumatization in Cebus.

    PubMed

    Rae, Todd C; Koppe, Thomas

    2008-11-01

    Several different factors have been hypothesized as explanations of variation in primate paranasal sinus size. Biomechanical forces, particularly those associated with mastication, are frequently evoked to account for differences in primate craniofacial pneumatization. To test whether masticatory stresses are responsible for maxillary sinus volume diversity, two platyrrhine species of the genus Cebus (C. apella and C. albifrons) were examined. The former has been identified as a hard object feeder, and many morphological differences between the two species are attributable to differences in the mechanical properties of their respective diets. Sinus volumes were derived from serial coronal CT scans of the crania of adults. Several external cranial measurements were used to scale sinus volume relative to the size of the face. Relative measures of maxillary sinus volume were compared using standard statistical techniques. In all comparisons, the two capuchin species do not differ from one another significantly at P < 0.05. Thus, this "natural experiment" fails to support the interpretation that biomechanical forces acting on the facial skeleton substantially affect the degree of paranasal pneumatization in primates. This result suggests that it is unlikely that the maxillary sinus performs any function in relation to masticatory stress; other factors must be responsible for the variation in sinus volume among primates.

  10. Pneumatic oscillator circuits for timing and control of integrated microfluidics.

    PubMed

    Duncan, Philip N; Nguyen, Transon V; Hui, Elliot E

    2013-11-05

    Frequency references are fundamental to most digital systems, providing the basis for process synchronization, timing of outputs, and waveform synthesis. Recently, there has been growing interest in digital logic systems that are constructed out of microfluidics rather than electronics, as a possible means toward fully integrated laboratory-on-a-chip systems that do not require any external control apparatus. However, the full realization of this goal has not been possible due to the lack of on-chip frequency references, thus requiring timing signals to be provided from off-chip. Although microfluidic oscillators have been demonstrated, there have been no reported efforts to characterize, model, or optimize timing accuracy, which is the fundamental metric of a clock. Here, we report pneumatic ring oscillator circuits built from microfluidic valves and channels. Further, we present a compressible-flow analysis that differs fundamentally from conventional circuit theory, and we show the utility of this physically based model for the optimization of oscillator stability. Finally, we leverage microfluidic clocks to demonstrate circuits for the generation of phase-shifted waveforms, self-driving peristaltic pumps, and frequency division. Thus, pneumatic oscillators can serve as on-chip frequency references for microfluidic digital logic circuits. On-chip clocks and pumps both constitute critical building blocks on the path toward achieving autonomous laboratory-on-a-chip devices.

  11. Pneumatic oscillator circuits for timing and control of integrated microfluidics

    PubMed Central

    Duncan, Philip N.; Nguyen, Transon V.; Hui, Elliot E.

    2013-01-01

    Frequency references are fundamental to most digital systems, providing the basis for process synchronization, timing of outputs, and waveform synthesis. Recently, there has been growing interest in digital logic systems that are constructed out of microfluidics rather than electronics, as a possible means toward fully integrated laboratory-on-a-chip systems that do not require any external control apparatus. However, the full realization of this goal has not been possible due to the lack of on-chip frequency references, thus requiring timing signals to be provided from off-chip. Although microfluidic oscillators have been demonstrated, there have been no reported efforts to characterize, model, or optimize timing accuracy, which is the fundamental metric of a clock. Here, we report pneumatic ring oscillator circuits built from microfluidic valves and channels. Further, we present a compressible-flow analysis that differs fundamentally from conventional circuit theory, and we show the utility of this physically based model for the optimization of oscillator stability. Finally, we leverage microfluidic clocks to demonstrate circuits for the generation of phase-shifted waveforms, self-driving peristaltic pumps, and frequency division. Thus, pneumatic oscillators can serve as on-chip frequency references for microfluidic digital logic circuits. On-chip clocks and pumps both constitute critical building blocks on the path toward achieving autonomous laboratory-on-a-chip devices. PMID:24145429

  12. Performance analysis and experiment validation of a pneumatic vibration isolator

    NASA Astrophysics Data System (ADS)

    Yang, Yuanyuan; Tan, Jiubin; Wang, Lei; Zhou, Tong

    2015-02-01

    A performance analysis and experiment validation of a pneumatic vibration isolator (PVI) that applied in the wafer stage of lithography is proposed in this work. The wafer stage of lithography is a dual-stage actuator system, including a long-stroke stage (LS) and a short-stroke stage (SS). In order to achieve the nanometer level positioning the isolator is designed to reduce the transmission of LS excitations to SS. In addition, considering the SS with six degrees of freedom and required to keep a strict constant temperature environment, the isolator need to have two functions, including the decoupling for vertical to horizontal and gravity compensation. In this isolator, a biaxial hinge was designed to decouple vertical rotation freedom, and a gas bearing was designed to decouple horizontal motion. The stiffness and damping of the pneumatic vibration isolator were analyzed. Besides, an analysis of the natural frequency and vibration transmissibility of the isolator is presented. In the end, the results show that vibration transmission is reduced significantly by the isolator and natural frequency can be lower than 0.6 Hz. This means that experimental results accord with the prediction model.

  13. Performance optimization of a pneumatic wave energy conversion device

    NASA Astrophysics Data System (ADS)

    Surko, S. W.

    1982-08-01

    The purpose of this study was, for the first time, to optimize the performance of a pneumatic wave energy conversion device. The experiments of Jolly and Newmaster (1979) and Trop and Casey (1980) left a capture chamber and turbine for further investigation. To optimize the system performance the turbine had to be first analyzed so that its power performance curves could be determined. These curves were needed to help define the possible overall performance of the system, and for the impedance matching of the system necessary for performance optimization. With this knowledge, an appropriate generator was purchased and a generator-turbine linkage designed and built. The completed system was then analyzed in the 380 ft wave tank at the U.S. Naval Academy to establish its optimum performance. From the research it is clear that pneumatic wave energy conversion is a promising concept. With several hundred of these devices situated some 100 km off the coast of the Pacific Northwest each device would be producing from 50 to 200 kW which would be transferred back to shore.

  14. Development of an air pneumatic suspension system for transtibial prostheses.

    PubMed

    Pirouzi, Gholamhossein; Abu Osman, Noor Azuan; Oshkour, Azim Ataollahi; Ali, Sadeeq; Gholizadeh, Hossein; Abas, Wan A B Wan

    2014-09-09

    The suspension system and socket fitting of artificial limbs have major roles and vital effects on the comfort, mobility, and satisfaction of amputees. This paper introduces a new pneumatic suspension system that overcomes the drawbacks of current suspension systems in donning and doffing, change in volume during daily activities, and pressure distribution in the socket-stump interface. An air pneumatic suspension system (APSS) for total-contact sockets was designed and developed. Pistoning and pressure distribution in the socket-stump interface were tested for the new APSS. More than 95% of the area between each prosthetic socket and liner was measured using a Tekscan F-Scan pressure measurement which has developed matrix-based pressure sensing systems. The variance in pressure around the stump was 8.76 kPa. APSS exhibits less pressure concentration around the stump, improved pressure distribution, easy donning and doffing, adjustability to remain fitted to the socket during daily activities, and more adaptability to the changes in stump volume. The volume changes were adjusted by utility of air pressure sensor. The vertical displacement point and reliability of suspension were assessed using a photographic method. The optimum pressure in every level of loading weight was 55 kPa, and the maximum displacement was 6 mm when 90 N of weight was loaded.

  15. Pneumatic interactive gait rehabilitation orthosis: design and preliminary testing.

    PubMed

    Belforte, G; Eula, G; Appendino, S; Sirolli, S

    2011-02-01

    Motor rehabilitation techniques based on passive movement of the lower limbs have been developed over the past 15 years. Gait training automation is the latest innovation in these techniques. This paper describes the design and development of a pneumatic interactive gait rehabilitation orthosis (PIGRO), as well as the first experimental results obtained with healthy subjects. PIGRO consists of a modular and size-adaptable exoskeleton, pneumatic actuation systems for the six actuated degrees of freedom (DoF), and a control unit. The foot orthosis and ankle actuation can be removed and/or replaced with orthopaedic shoes so as to permit gait rehabilitation while advancing between parallel bars with ground contact and partial body weight support (i.e. not walking in place). Control logic provides closed-loop position control independently on each joint, with position feedback for each joint in real time. Imposed curves are physiological joint angles: it is also possible to choose between activating one or both legs and to modify curves to obtain different gait patterns if required. The paper concludes with a presentation of experimental results for the device's performance.

  16. [Conservative management of esophageal perforation after pneumatic dilatation for achalasia].

    PubMed

    Scatton, Olivier; Gaudric, Marianne; Massault, Pierre-Philippe; Chaussade, Stanislas; Houssin, Didier; Dousset, Bertrand

    2002-10-01

    To assess the results and indications of conservative management of esophageal perforation following pneumatic dilatation for achalasia. Thirteen esophageal perforations complicating 524 dilatations in 412 patients (3%) were diagnosed by esophagogram. Medical treatment consisted of nasogastric succion, antibiotics and pleural drainage, if necessary. Conservative surgical treatment included left thoracophrenotomy, perforation closure, controlateral myotomy and anterior fundoplication. Surgical decision was based upon clinical and radiological parameters. Functional outcome was assessed by the means of the Eckardt's grading score. Six patients were successfully managed by medical treatment. Seven patients underwent conservative surgery, three of whom after failure of medical treatment. The presence of a pneumomediastinum at initial presentation led to immediate (n=2) or delayed (n=2) surgery in all instances. No patients died. In the surgical group, morbidity consisted of one wound infection, one pleural effusion and one venous thrombosis. One severe chest infection occurred in the medical group. Oral feeding was reintroduced after a median of 10 and 11 days in the surgical and medical groups, respectively. Functional results were satisfactory and similar in both groups. Conservative medical or surgical management of oesophageal perforation following pneumatic dilatation is safe, if the diagnosis is done early. Pneumomediastinum at initial presentation seems to predict failure of conservative medical treatment.

  17. Development of an Air Pneumatic Suspension System for Transtibial Prostheses

    PubMed Central

    Pirouzi, Gholamhossein; Osman, Noor Azuan Abu; Oshkour, Azim Ataollahi; Ali, Sadeeq; Gholizadeh, Hossein; Wan Abas, Wan A. B.

    2014-01-01

    The suspension system and socket fitting of artificial limbs have major roles and vital effects on the comfort, mobility, and satisfaction of amputees. This paper introduces a new pneumatic suspension system that overcomes the drawbacks of current suspension systems in donning and doffing, change in volume during daily activities, and pressure distribution in the socket-stump interface. An air pneumatic suspension system (APSS) for total-contact sockets was designed and developed. Pistoning and pressure distribution in the socket-stump interface were tested for the new APSS. More than 95% of the area between each prosthetic socket and liner was measured using a Tekscan F-Scan pressure measurement which has developed matrix-based pressure sensing systems. The variance in pressure around the stump was 8.76 kPa. APSS exhibits less pressure concentration around the stump, improved pressure distribution, easy donning and doffing, adjustability to remain fitted to the socket during daily activities, and more adaptability to the changes in stump volume. The volume changes were adjusted by utility of air pressure sensor. The vertical displacement point and reliability of suspension were assessed using a photographic method. The optimum pressure in every level of loading weight was 55 kPa, and the maximum displacement was 6 mm when 90 N of weight was loaded. PMID:25207872

  18. Radiation Damage Study in Natural Zircon Using Neutrons Irradiation

    SciTech Connect

    Lwin, Maung Tin Moe; Amin, Yusoff Mohd.; Kassim, Hasan Abu; Mohamed, Abdul Aziz; Karim, Julia Abdul

    2011-03-30

    Changes of atomic displacements in crystalline structure of natural zircon (ZrSiO{sub 4}) can be studied by using neutron irradiation on the surface of zircon and compared the data from XRD measurements before and after irradiation. The results of neutron irradiation on natural zircon using Pneumatic Transfer System (PTS) at PUSPATI TRIGA Research Reactor in the Malaysian Nuclear Agency are discussed in this work. The reactor produces maximum thermal power output of 1 MWatt and the neutron flux of up to 1x10{sup 13} ncm{sup -2}s{sup -1}. From serial decay processes of uranium and thorium radionuclides in zircon crystalline structure, the emission of alpha particles can produce damage in terms of atomic displacements in zircon. Hence, zircon has been extensively studied as a possible candidate for immobilization of fission products and actinides.

  19. Dynamic Friction Performance of a Pneumatic Cylinder with Al2O3 Film on Cylinder Surface.

    PubMed

    Chang, Ho; Lan, Chou-Wei; Wang, Hao-Xian

    2015-11-01

    A friction force system is proposed for accurately measuring friction force and motion properties produced by reciprocating motion of piston in a pneumatic cylinder. In this study, the proposed system is used to measure the effects of lubricating greases of different viscosities on the friction properties of pneumatic cylinder, and improvement of stick-slip motion for the cylinder bore by anodizing processes. A servo motor-driven ball screw is used to drive the pneumatic cylinder to be tested and to measure the change in friction force of the pneumatic cylinder. Experimental results show, that under similar test conditions, the lubricating grease with viscosity VG100 is best suited for measuring reciprocating motion of the piston of pneumatic cylinder. The wear experiment showed that, in the Al2O3 film obtained at a preset voltage 40 V in the anodic process, the friction coefficient and hardness decreased by 55% and increased by 274% respectively, thus achieving a good tribology and wear resistance. Additionally, the amplitude variation in the friction force of the pneumatic cylinder wall that received the anodizing treatment was substantially reduced. Additionally, the stick-slip motion of the pneumatic cylinder during low-speed motion was substantially improved.

  20. Body mass and foraging ecology predict evolutionary patterns of skeletal pneumaticity in the diverse "waterbird" clade.

    PubMed

    Smith, Nathan D

    2012-04-01

    Extensive skeletal pneumaticity (air-filled bone) is a distinguishing feature of birds. The proportion of the skeleton that is pneumatized varies considerably among the >10,000 living species, with notable patterns including increases in larger bodied forms, and reductions in birds employing underwater pursuit diving as a foraging strategy. I assess the relationship between skeletal pneumaticity and body mass and foraging ecology, using a dataset of the diverse "waterbird" clade that encompasses a broad range of trait variation. Inferred changes in pneumaticity and body mass are congruent across different estimates of phylogeny, whereas pursuit diving has evolved independently between two and five times. Phylogenetic regressions detected positive relationships between body mass and pneumaticity, and negative relationships between pursuit diving and pneumaticity, whether independent variables are considered in isolation or jointly. Results are generally consistent across different estimates of topology and branch lengths. "Predictive" analyses reveal that several pursuit divers (loons, penguins, cormorants, darters) are significantly apneumatic compared to their relatives, and provide an example of how phylogenetic information can increase the statistical power to detect taxa that depart from established trait correlations. These findings provide the strongest quantitative comparative support yet for classical hypotheses regarding the evolution of avian skeletal pneumaticity. © 2011 The Author(s). Evolution© 2011 The Society for the Study of Evolution.

  1. Oculoscopy in Rabbits and Rodents.

    PubMed

    Jekl, Vladimir; Hauptman, Karel; Knotek, Zdenek

    2015-09-01

    Ophthalmic diseases are common in rabbits and rodents. Fast and definitive diagnosis is imperative for successful treatment of ocular diseases. Ophthalmic examination in rabbits and rodents can be challenging. Oculoscopy offers great magnification for the examination of the ocular structures in such animals, including the evaluation of cornea, anterior eye chamber, limbus, iris, lens, and retina. To date, oculoscopy has been described only sporadically and/or under experimental conditions. This article describes the oculoscopy technique, normal and abnormal ocular findings, and the most common eye disorders diagnosed with the aid of endoscopy in rabbits and rodents.

  2. Irradiation subassembly

    DOEpatents

    Seim, O.S.; Filewicz, E.C.; Hutter, E.

    1973-10-23

    An irradiation subassembly for use in a nuclear reactor is described which includes a bundle of slender elongated irradiation -capsules or fuel elements enclosed by a coolant tube and having yieldable retaining liner between the irradiation capsules and the coolant tube. For a hexagonal bundle surrounded by a hexagonal tube the yieldable retaining liner may consist either of six segments corresponding to the six sides of the tube or three angular segments each corresponding in two adjacent sides of the tube. The sides of adjacent segments abut and are so cut that metal-tometal contact is retained when the volume enclosed by the retaining liner is varied and Springs are provided for urging the segments toward the center of the tube to hold the capsules in a closely packed configuration. (Official Gazette)

  3. Urethral healing in rabbits.

    PubMed

    Scherz, H C; Kaplan, G W; Boychuk, D I; Landa, H M; Haghighi, P

    1992-08-01

    We studied urethral healing in New Zealand white rabbits by histological examination after insult (urethral catheter) or injury (urethrotomy) specifically for acute and chronic inflammation, fibrosis, fistulas, squamous metaplasia, foreign body giant cells and urethral dilatation. Urethral catheterization resulted in increased inflammation and fibrosis compared to noncatheterized animals. Skin closure techniques and materials resulted in an inflammatory response that may extend to and involve the urethra. Minor differences in suture size were not an important variable but the persistence of suture material may have a role in the degree of inflammation and the formation of foreign body giant cells. Transepithelial closure techniques drag epithelial cells into subcutaneous tissues and may predispose to fistula formation.

  4. The qualitative assessment of pneumatic actuators operation in terms of vibration criteria

    NASA Astrophysics Data System (ADS)

    Hetmanczyk, M. P.; Michalski, P.

    2015-11-01

    The work quality of pneumatic actuators can be assessed in terms of multiple criteria. In the case of complex systems with pneumatic actuators retained at end positions (with occurrence of piston impact in cylinder covers) the vibration criteria constitute the most reliable indicators. The paper presents an impact assessment on the operating condition of the rodless pneumatic cylinder regarding to selected vibrational symptoms. On the basis of performed analysis the authors had shown meaningful premises allowing an evaluation of the performance and tuning of end position damping piston movement with usage the most common diagnostic tools (portable vibration analyzers). The presented method is useful in tuning of parameters in industrial conditions.

  5. Portal venous gas and cardiopulmonary arrest during pneumatic reduction of an ileocolic intussusception.

    PubMed

    Ryan, Mark L; Fields, Jonathan M; Sola, Juan E; Neville, Holly L

    2011-04-01

    We present the case of an 8-month-old infant with a small bowel obstruction secondary to an ileocolic intussusception without a pathologic lead point. During pneumatic reduction, the patient went into cardiopulmonary arrest, at which point portal venous gas (PVG) was visualized on radiography. Here we present-to our knowledge-the first reported case of PVG secondary to pneumatic reduction of an intussusception along with a review of the literature regarding known complications of pneumatic reduction and the etiologies of PVG.

  6. Gait Using Pneumatic Brace for End-Stage Knee Osteoarthritis.

    PubMed

    Kapadia, Bhaveen H; Cherian, Jeffrey Jai; Starr, Roland; Chughtai, Morad; Mont, Michael A; Harwin, Steven F; Bhave, Anil

    2016-04-01

    More than 20 million individuals in the United States are affected by knee osteoarthritis (OA), which can lead to altered biomechanics and excessive joint loading. The use of an unloader pneumatic brace with extension assist has been proposed as a nonoperative treatment modality that may improve gait mechanics and correct knee malalignment. We assessed the following parameters in patients who have knee OA treated with and without a brace: (1) changes in temporospatial parameters in gait; (2) knee range of motion, knee extension at heel strike, and foot placement; (3) knee joint moments and impulse; and (4) changes in dynamic stiffness and rate of change of knee flexion during midstance to terminal stance. This 2:1 prospective, randomized, single-blinded trial evaluated 36 patients (24 brace and 12 matching). OA knee patients were randomized to receive either a pneumatic unloader brace or a standard nonoperative treatment regimen as the matching cohort for a 3-month period. They underwent evaluation of gait parameters using a three-dimensional gait analysis system at their initial appointment and at 3 months follow-up. All the testing, pre- and postbracing were performed without wearing the brace to examine for retained effects. Treatment with the brace led to significant improvements versus standard treatment in various gait parameters. Patients in the brace group had improvements in walking speed, knee extension at heel strike, total range of motion, knee joint forces, and rate of knee flexion from midstance to terminal stance when compared with the matching cohort. Knee OA patients who used a pneumatic unloader brace for 3 months for at least 3 hours per day had significant improvements various gait parameters when compared with a standard nonoperative therapy cohort. Braced patients demonstrated gait-modifying affects when not wearing the brace. These results are encouraging and suggest that this device represents a promising treatment modality for knee OA that

  7. Efficient Method for Calculating Hydraulic Conductivity from Pneumatic Slug Tests

    NASA Astrophysics Data System (ADS)

    Peng, X.; Cheung, B.; Knappett, P. S.; Zhan, H.

    2014-12-01

    Pneumatic slug tests are widely used in characterizing the hydraulic conductivity of aquifers. In comparison to a manual slug test wherein the water level is measured using a water level tape, pneumatic slug tests are especially useful when the water level recovery is very fast (<10 sec) in a high hydraulic conductivity (K) aquifer (>10-4 m/s) and when the recovery is very slow (<10-7 m/s). The submerged pressure transducer monitors pressure changes at intervals of fractions of a second and for longer recoveries no personnel are required to make repeated measurements. A pneumatic slug test begins with pressurizing the well at the well head using an air pump followed by several minutes waiting for the pressure in the well to equalize with the pressure outside the well screen. In semi-confined settings this equalization may take >5 minutes. In lower K media it's not always feasible to wait until the well fully recovers before making the next replicate measurement. Therefore, it would greatly reduce the time needed to make replicate measurements if these waiting times could be reduced. Here we present a method using non-linear least squares regression on a portion of the recovery curve to simultaneously fit 3 parameters used to determine K from a slug tests using the Hvorslev method. The advantage of this approach is that waiting for the well to reach static head between replicate measurements is not required. This is because the regression fits static head (H) from the shape of only part the recovery curve. We compare the resulting K values from this new method to values obtained from manually measured static heads for triplicate measurements on 50 wells. The well's settings ranged from unconfined to semi-confined and K ranged from 10-3 to 10-5 m/s. The new method gave identical results. We performed the same comparison on a subset 16 wells using data collected in half the time, where only part of the recovery curves were measured before starting the next replicate

  8. Threshold Lesion Temperatures in Laser-Irradiated Rabbit Eyes

    DTIC Science & Technology

    1975-03-31

    laser, tuned to a primary wavelength of 4880A. Pulse length was controlled with an electronic shutter, from Vincent Associates, Model 23XDB2X5...with a narrow beam adapter and 25A Detector Head. Neutral density filters were placed in the laser beam path to control intensity. Laboratory...necessary to control hemorrhaging. Six sutures were placed through the conjunctiva and the eyeholder was sewn onto the front of the eye. A contact

  9. The influence of radiation therapy on subperiosteal hydroxyapatite implants in rabbits

    SciTech Connect

    Khateery, S.; Waite, P.D.; Lemons, J.E. )

    1991-07-01

    Granular hydroxyapatite (HA) was implanted into subperiosteal pockets along both the right and left proximal tibias of 12 adult New Zealand white rabbits. The left extremities of 10 rabbits served as controls, whereas the right sides were irradiated with 2,250 rad in three doses over 5 days. The animals were killed at 1-week intervals starting at 2 weeks postirradiation. One half of each site was evaluated using standard histologic techniques while the other half was examined as a nondecalcified section. The quantity and the quality of new bone formation was determined using a rating scale and histomorphometric digitization. The results of this 4-month study showed that the amount of new bone formation around the HA granules was significantly greater in the irradiated sites. The irradiation produced no deleterious effects on the implant or the surrounding tissue areas.

  10. The cottontail rabbits of Virginia

    USGS Publications Warehouse

    Llewellyn, L.M.; Handley, C.O.

    1945-01-01

    Five races of cottontail rabbits belonging to three species occur in Virginia. One of them, the Mearns cottontail (Sylvilagus floridanus mearnsi), is reported here for the first time. It occurs in six southwestern counties of the state, while the eastern cottontail (S. f. mallurus) occurs in the remainder of the state with the exception of Smith and Fishermans islands off the eastern coast of Cape Charles, where it is replaced by Hitchens cottontail (S. f. hitchensi). The New England cottontail (S. transitionalis) is found on the higher mountain peaks, above 3000 feet, and the swamp rabbit (S. palustris) occurs in the Dismal Swamp region of southeastern Virginia.....The height of the breeding season for the eastern cottontail in Virginia is March and April, but breeding continues through the entire year except in December and January. The average litter size based on embryo counts was 4.7. The sex ratio of 234 specimens from all parts of the state, taken mostly in the December to February period, was 53 males to 47 females. That of a group of 145 rabbits live-trapped at Blacksburg during February and Marchwas 58 males to 42 females. The figures show that males are more active than females during the winter months, and therefore are more easily taken then....In transplanting cottontails from one section of the state to another, it is recommended that only cottontails of the same race as those originally present in the region being restocked be released there....Tularemia is not a common disease among rabbits in Virginia, but the rabbit ticks are often carriers of the disease and may transmit it to rabbits. Rabbit ticks are also found to be carriers of Rocky Mountain fever and American Q. fever. After the ticks drop off the rabbits to hibernate in the ground, which is likely to occur during mid-winter in Virginia, there is relatively little danger of humans contracting tularemia by contact with rabbits. Present laws in Virginia which prohibit rabbit hunting until the

  11. Irradiated foods

    MedlinePlus

    ... it reduces the risk for food poisoning . Food irradiation is used in many countries. It was first approved in the U.S. to prevent sprouts on white potatoes, and to control insects on wheat and in certain spices and seasonings.

  12. Repeating pneumatic pipe-gun for plasma fueling

    NASA Astrophysics Data System (ADS)

    Viniar, I.; Sudo, S.

    1997-03-01

    A pellet injector of the repeating pneumatic pipe-gun type has been designed for plasma fueling applications. Its use reduces the time for pellet formation by an in situ technique from 2 to 3 min to 2-10 s. The basic idea of the proposed approach to pellet formation is to melt prefrozen solid fuel and to admit it through a porous unit into a barrel for refreezing. The injector provides for a continuous injection of an unlimited number of pellets. Over 250 hydrogen and deuterium pellets of 3 mm diameter and 3-10 mm in length were accelerated to 1.2 km/s at a rate of 1 pellet per 10-34 s by manually controlled injector operation. An automatically controlled multishot pellet injector (>10 barrels) is capable of providing a continuous and reliable fueling of large fusion devices such as the large helical device and the International Thermonuclear Experimental Reactor (ITER).

  13. Endoscope-guided pneumatic dilation for treatment of esophageal achalasia

    PubMed Central

    Chuah, Seng-Kee; Wu, Keng-Liang; Hu, Tsung-Hui; Tai, Wei-Chen; Changchien, Chi-Sin

    2010-01-01

    Pneumatic dilation (PD) is considered to be the first line nonsurgical therapy for achalasia. The principle of the procedure is to weaken the lower esophageal sphincter by tearing its muscle fibers by generating radial force. The endoscope-guided procedure is done without fluoroscopic control. Clinicians usually use a low-compliance balloon such as Rigiflex dilator to perform endoscope-guided PD for the treatment of esophageal achalasia. It has the advantage of determining mucosal injury during the dilation process, so that a repeat endoscopy is not needed to assess the mucosal tearing. Previous studies have shown that endoscope-guided PD is an efficient and safe nonsurgical therapy with results that compare well with other treatment modalities. Although the results may be promising, long-term follow-up is required in the near future. PMID:20101764

  14. Design of a biped robot actuated by pneumatic artificial muscles.

    PubMed

    Liu, Yixiang; Zang, Xizhe; Liu, Xinyu; Wang, Lin

    2015-01-01

    High compliant legs are essential for the efficient versatile locomotion and shock absorbency of humans. This study proposes a biped robot actuated by pneumatic artificial muscles to mimic human locomotion. On the basis of the musculoskeletal architecture of human lower limbs, each leg of the biped robot is modeled as a system of three segments, namely, hip joint, knee joint, and ankle joint, and eleven muscles, including both monoarticular and biarticular muscles. Each rotational joint is driven by a pair of antagonistic muscles, enabling joint compliance to be tuned by operating the pressure inside the muscles. Biarticular muscles play an important role in transferring power between joints. Walking simulations verify that biarticular muscles contribute to joint compliance and can absorb impact energy when the robot makes an impact upon ground contact.

  15. Pneumatic Micro Dispenser Chip for Portable Micro Analysis Devices

    NASA Astrophysics Data System (ADS)

    Hasegawa, Tadahiro; Tsuji, Toshiyuki; Ikuta, Koji

    The prototype of the pneumatic micro dispenser chip for portable micro analysis devices was developed successfully. This micro dispenser succeeded to divide liquid into 1µL without any dead volume by decompressing and the compressing air in only one micro pump. The dispensing operation is achieved by the original micro liquid detecting method and four hat-shaped check valves. The detecting method utilized the refraction of the infrared rays LED. Not only passage of the fluid into the channel but also its existence can be detected as TTL level signal. The hat-shaped silicone rubber valve which functions itself as a unidirectional passive valve was proposed. The check valve with low opening pressure (3kPa) and high inverse pressure (over 300kPa) was developed successfully. This micro dispenser chip is useful for portable micro analysis devices.

  16. A high performance pneumatic braking system for heavy vehicles

    NASA Astrophysics Data System (ADS)

    Miller, Jonathan I.; Cebon, David

    2010-12-01

    Current research into reducing actuator delays in pneumatic brake systems is opening the door for advanced anti-lock braking algorithms to be used on heavy goods vehicles. However, these algorithms require the knowledge of variables that are impractical to measure directly. This paper introduces a sliding mode braking force observer to support a sliding mode controller for air-braked heavy vehicles. The performance of the observer is examined through simulations and field testing of an articulated heavy vehicle. The observer operated robustly during single-wheel vehicle simulations, and provided reasonable estimates of surface friction from test data. The effect of brake gain errors on the controller and observer are illustrated, and a recursive least squares estimator is derived for the brake gain. The estimator converged within 0.3 s in simulations and vehicle trials.

  17. The role of particle collisions in pneumatic transport

    NASA Technical Reports Server (NTRS)

    Mastorakos, E.; Louge, M.; Jenkins, J. T.

    1989-01-01

    A model of dilute gas-solid flow in vertical risers is developed in which the particle phase is treated as a granular material, the balance equations for rapid granular flow are modified to incorporate the drag force from the gas, and boundary conditions, based on collisional exchanges of momentum and energy at the wall, are employed. In this model, it is assumed that the particle fluctuations are determined by inter-particle collisions only and that the turbulence of the gas is unaffected by the presence of the particles. The model is developed in the context of, but not limited to, steady, fully developed flow. A numerical solution of the resulting governing equations provides concentration profiles generally observed in dilute pneumatic flow, velocity profiles in good agreement with the measurements of Tsuji, et al. (1984), and an explanation for the enhancement of turbulence that they observed.

  18. Velocity control of nanoliter droplets using a pneumatic dispensing system

    NASA Astrophysics Data System (ADS)

    Lee, Sangmin; Choi, In Ho; Kim, Young Kwon; Kim, Joonwon

    2014-12-01

    This paper introduces a pneumatic dispensing system to control the velocity of nanoliter droplets with small variation of volume. The system consists of a flexible membrane integrated with a backflow stopper. This unique dispensing mechanism can control the velocity of droplets according to applied positive pressures regardless of other operating conditions and design parameters. The range of droplet velocities is shifted by the flow resistance at the outlet under the same cross-section area. Our dispensing system can eject droplets of desired volume at a velocity that can be easily controlled by selecting design parameters and operating conditions. This dispensing system will provide a reliable performance within an optimized condition stably to deposit droplets onto accurate locations.

  19. The role of particle collisions in pneumatic transport

    NASA Astrophysics Data System (ADS)

    Mastorakos, E.; Louge, M.; Jenkins, J. T.

    1989-09-01

    A model of dilute gas-solid flow in vertical risers is developed in which the particle phase is treated as a granular material, the balance equations for rapid granular flow are modified to incorporate the drag force from the gas, and boundary conditions, based on collisional exchanges of momentum and energy at the wall, are employed. In this model, it is assumed that the particle fluctuations are determined by inter-particle collisions only and that the turbulence of the gas is unaffected by the presence of the particles. The model is developed in the context of, but not limited to, steady, fully developed flow. A numerical solution of the resulting governing equations provides concentration profiles generally observed in dilute pneumatic flow, velocity profiles in good agreement with the measurements of Tsuji, et al. (1984), and an explanation for the enhancement of turbulence that they observed.

  20. Design of pneumatic proportional flow valve type 5/3

    NASA Astrophysics Data System (ADS)

    Laski, P. A.; Pietrala, D. S.; Zwierzchowski, J.; Czarnogorski, K.

    2017-08-01

    In this paper the 5/3-way pneumatic, proportional flow valve was designed and made. Stepper linear actuator was used to move the spool. The valve is controlled by the controlled based on a AVR microcontroller. Virtual model of the valve was created in CAD. The real element was made based on a standard 5/3-way manually actuated valve with hand lever, which was dismounted and replaced by linear stepper motor. All the elements was mounted in a specially made housing. The controller consists of microcontroller Atmega16, integrated circuit L293D, display, two potentiometers, three LEDs and six buttons. Series of research was also conducted. Simulation research were performed using CFD by the Flow Simulation addition to SolidWorks. During the experiments the valve characteristics of flow and pressure was determined.

  1. Preliminary measurements on heat balance in pneumatic tires

    NASA Technical Reports Server (NTRS)

    Nybakken, G. H.; Collart, D. Y.; Staples, R. J.; Lackey, J. I.; Clark, S. K.; Dodge, R. N.

    1973-01-01

    A variety of tests was undertaken to determine the nature of heat generation associated with a pneumatic tire operating under various conditions. Tests were conducted to determine the magnitude and distribution of internally generated heat caused by hysteresis in the rubber and ply fabric in an automobile tire operating under conditions of load, pressure, and velocity representative of normal operating conditions. These included tests at various yaw angles and tests with braking applied. In other tests, temperature sensors were mounted on a road to measure the effect of a tire rolling over and an attempt was made to deduce the magnitude and nature of interfacial friction from the resulting information. In addition, tests were performed using the scratch plate technique to determine the nature of the motion between the tire and road. Finally, a model tire was tested on a roadwheel, the surface covering which could be changed, and an optical pyrometer was used to measure rubber surface temperatures.

  2. Phospholamban Overexpression in Transgenic Rabbits

    PubMed Central

    Pattison, J. Scott; Waggoner, Jason R.; James, Jeanne; Martin, Lisa; Gulick, James; Osinska, Hanna; Klevitsky, Raisa; Kranias, Evangelia G.; Robbins, Jeffrey

    2008-01-01

    There has been considerable interest in pursuing phospholamban as a putative therapeutic target for overcoming depressed calcium handling in human heart failure. Studies predominantly done in mice have shown that phospholamban is a key regulator of sarcoplasmic reticulum calcium cycling and cardiac function. However, mice differ significantly from humans in how they regulate calcium, whereas rabbits better recapitulate human cardiac function and calcium handling. To investigate phospholamban’s role in the rabbit heart, transgenic rabbits that overexpressed wild-type phospholamban in the ventricular cardiomyocytes and slow-twitch skeletal muscles were generated. Rabbits expressing high levels of phospholamban were not viable due to severe skeletal muscle wasting, the onset of cardiac pathology and early death. A viable transgenic line exhibited a 30% increase in PLN protein levels in the heart. These animals showed isolated foci of cardiac pathology, but cardiac function as well as the response to β-adrenergic stimulation were normal. SR-calcium uptake measurements showed that the transgenic hearts had the expected reduced affinity for calcium. The data show that phospholamban-overexpressing transgenic rabbits differ markedly in phenotype from analogous transgenic mice in that rabbits are quite sensitive to alterations in phospholamban levels. Exceeding a relatively narrow window of phospholamban expression results in significant morbidity and early death. PMID:17882530

  3. Photobiomodulation with LED and laser in repair of mandibular socket rabbit: clinical evaluation, histological, and histomorphometric.

    PubMed

    Comunian, Cláudio Rômulo; Custódio, Antônio Luis Neto; de Oliveira, Leandro Junqueira; Dutra, Carlos Eduardo Assis; D'almeida Ferreira Neto, Milton; Rezende, Cleuza Maria Faria

    2017-06-01

    The aim of this study was to evaluate the effects of LED and low-intensity laser on the healing of rabbit dental alveoli. A total of 18 rabbits were divided into three groups of six; all rabbits underwent surgical extraction of the first lower right premolar. Following surgery, group 1 received LED irradiation, group 2 received laser irradiation, and group 3 were untreated controls. The initial applications of LED and laser began 48 h after tooth extraction and were given perpendicularly to the dental alveoli. The three groups were clinically evaluated for 18 days in the postoperative period. At 90 days, the rabbits were euthanized and the mandibular fragments containing the healing alveoli were collected. These fragments initially underwent computed tomography scans and bone density was measured in Hounsfield units. Following this, the fragments were processed and stained with hematoxylin and eosin for histological and histomorphometric analysis. The results were compatible between the clinical, histological, and histomorphometric parameters evaluated. There were no statistical differences between the LED and laser groups. However, the difference of the average bone density between laser and control group was not statistically significant. It was found that photobiomodulation with LASER and LED presented effects. However, only the LED demonstrated a beneficial effect on the process of bone repair in the dental alveoli of rabbits.

  4. Analysis of nonlinear elastic behavior in miniature pneumatic artificial muscles

    NASA Astrophysics Data System (ADS)

    Hocking, Erica G.; Wereley, Norman M.

    2013-01-01

    Pneumatic artificial muscles (PAMs) are well known for their excellent actuator characteristics, including high specific work, specific power, and power density. Recent research has focused on miniaturizing this pneumatic actuator technology in order to develop PAMs for use in small-scale mechanical systems, such as those found in robotic or aerospace applications. The first step in implementing these miniature PAMs was to design and characterize the actuator. To that end, this study presents the manufacturing process, experimental characterization, and analytical modeling of PAMs with millimeter-scale diameters. A fabrication method was developed to consistently produce low-cost, high performance, miniature PAMs using commercially available materials. The quasi-static behavior of these PAMs was determined through experimentation on a single actuator with an active length of 39.16 mm (1.54 in) and a diameter of 4.13 mm (0.1625 in). Testing revealed the PAM’s full evolution of force with displacement for operating pressures ranging from 207 to 552 kPa (30-80 psi in 10 psi increments), as well as the blocked force and free contraction at each pressure. Three key nonlinear phenomena were observed: nonlinear PAM stiffness, hysteresis of the force versus displacement response for a given pressure, and a pressure deadband. To address the analysis of the nonlinear response of these miniature PAMs, a nonlinear stress versus strain model, a hysteresis model, and a pressure bias are introduced into a previously developed force balance analysis. Parameters of these nonlinear model refinements are identified from the measured force versus displacement data. This improved nonlinear force balance model is shown to capture the full actuation behavior of the miniature PAMs at each operating pressure and reconstruct miniature PAM response with much more accuracy than previously possible.

  5. Implementing AORN recommended practices for care of patients undergoing pneumatic tourniquet-assisted procedures.

    PubMed

    Hicks, Rodney W; Denholm, Bonnie

    2013-10-01

    Perioperative nurses are likely to encounter the use of pneumatic tourniquets in a variety of operative and invasive extremity procedures. Use of a pneumatic tourniquet offers an opportunity to obtain a near-bloodless surgical field; however, the use of tourniquets is not without risk. Unfavorable outcomes include pain, thrombotic events, nerve compression injuries, and disruption of skin integrity. Perioperative nurses should be familiar with the indications, contraindications, and changes in physiology associated with pneumatic tourniquet use. The revised AORN "Recommended practices for care of patients undergoing pneumatic tourniquet-assisted procedures" is focused on the perioperative nurse's role in patient care and provides guidance for developing, implementing, and evaluating practices that promote patient safety and improve the likelihood of positive outcomes. Copyright © 2013 AORN, Inc. Published by Elsevier Inc. All rights reserved.

  6. The Sterile Elastic Exsanguination Tourniquet vs. the Pneumatic Tourniquet for Total Knee Arthroplasty.

    PubMed

    Brin, Yaron S; Feldman, Viktor; Ron Gal, Itai; Markushevitch, Michael; Regev, Amit; Stern, Abraham

    2015-04-01

    We compared the sterile elastic exsanguination tourniquet and the pneumatic tourniquet for total knee arthroplasty. 145 patients were operated on using a pneumatic tourniquet and 166 with the sterile elastic exsanguination tourniquet. Patients with the sterile elastic exsanguination tourniquet had a smaller decrease in hemoglobin on post-operative days one (P<0.028) and three (P<0.045). The amount of blood collected from drains at 24h was significantly lower in the sterile elastic exsanguination group. A trend towards a higher rate of wound complications within 3months following the operation was found in the pneumatic tourniquet group. The sterile elastic exsanguination tourniquet works at least as good as the pneumatic one. Copyright © 2014 Elsevier Inc. All rights reserved.

  7. Teaching Mathematical and Scientific Concepts through the Use of a Pneumatic Arm Wrestling Machine.

    ERIC Educational Resources Information Center

    Johnson, William W., Jr.

    1994-01-01

    Describes a learning activity in which students build a pneumatic arm wrestling machine, thus combining their interest in arm wrestling while making direct applications to many scientific and mathematical concepts. (JOW)

  8. Gentle blood aspiration and tube cushioning reduce pneumatic tube system interference in lactate dehydrogenase assays.

    PubMed

    Strubi-Vuillaume, Isabelle; Carlier, Valentine; Obeuf, Catherine; Vasseur, Francis; Maury, J-Claude; Maboudou, Patrice; Mangalaboyi, Jacques; Durocher, Alain; Launay, David; Noel, Christian; Brousseau, Thierry

    2016-03-01

    Use of a hospital pneumatic tube system may be associated with measurement errors. A venous blood sample was collected from 79 patients into a pair of lithium heparin tubes; one tube was sent to the laboratory by porter and the other was sent via the pneumatic tube system. Plasma lactate dehydrogenase concentrations were then assayed. Lactate dehydrogenase concentrations were overestimated (median bias: 18.8%) when evacuated vacuum lithium heparin tubes were sent by pneumatic tube system. This bias was reduced by bubble-wrapping the standard lithium heparin tube or using Monovette lithium heparin tubes in aspiration mode (median bias: +8.7% and -0.3%, respectively). Cushioning and aspiration-mode sampling may limit pneumatic tube system-associated overestimation of lactate dehydrogenase concentrations. © The Author(s) 2015.

  9. [The scintigraphic assessment of the patients suffering from cardia achalasia, treated by pneumatic dilatation].

    PubMed

    Stan, Mărioara; Bălan, G; Rusu, Maria; Ciortescu, Irina; Popa, Florentina

    2002-01-01

    The esophageal scintigraphy is a technique used to evaluate the motility and the clearance of the esophagus. The patients with achalasia of the cardia were evaluated, before treating them with pneumatic dilatation and after. The reason is to evaluate the efficiency of the pneumatic dilatation technique in the treatment of esophageal achalasia. The pneumatic dilatation with an instrument type Rigiflex is a well/handled and used technique in our clinic. In the study 22 patients were included and we had in view the esophageal transit time and the residuary radioactivity before and after the pneumatic dilatation. We established an important statistical improvement of the data obtained after the dilatation comparative with the data before the treatment (p < 0.01).

  10. Application of Model-based Prognostics to a Pneumatic Valves Testbed

    NASA Technical Reports Server (NTRS)

    Daigle, Matthew; Kulkarni, Chetan S.; Gorospe, George

    2014-01-01

    Pneumatic-actuated valves play an important role in many applications, including cryogenic propellant loading for space operations. Model-based prognostics emphasizes the importance of a model that describes the nominal and faulty behavior of a system, and how faulty behavior progresses in time, causing the end of useful life of the system. We describe the construction of a testbed consisting of a pneumatic valve that allows the injection of faulty behavior and controllable fault progression. The valve opens discretely, and is controlled through a solenoid valve. Controllable leaks of pneumatic gas in the testbed are introduced through proportional valves, allowing the testing and validation of prognostics algorithms for pneumatic valves. A new valve prognostics approach is developed that estimates fault progression and predicts remaining life based only on valve timing measurements. Simulation experiments demonstrate and validate the approach.

  11. Throttle pneumatic impact mechanism equipped with afterburner idle-stroke chamber

    NASA Astrophysics Data System (ADS)

    Dedov, Alexey; Frantseva, Eleanor; Dmitriev, Mikhail

    2017-01-01

    Pneumatic impact mechanisms are widely used in construction, mining and other economic sectors of a country. Such mechanisms are a base for a wide range of machines of various types and dimensions from hand-held tools to mounted piling hammers with impact energy up to 10 000 J. This paper is aimed at creation of pneumatic impact mechanism with the improved characteristics, including operation, energy use, weight and size which is especially important in space-limited working conditions. The research methods include development of computer mathematical model that can solve equations system and test a prototype model at the experimental stand. As a result of conducted research the pneumatic impact mechanism with the improved characteristics was developed. An engineering method for calculating throttle pneumatic impact mechanisms with a preset value of impact energy from 1 to 20 000 was investigated. This method allows creating percussive machines of a wide range of application.

  12. Pattern design of a non-pneumatic tyre for stiffness using topology optimization

    NASA Astrophysics Data System (ADS)

    Gwun Jang, In; Sung, Young Hwa; Jong Yoo, Eui; Kwak, Byung Man

    2012-02-01

    Non-pneumatic tyres have been developed and are being investigated, but are not very prevalent. Many design studies are still needed from the viewpoint of material, pattern, and structures. However, no systematic research for such important design issues has been reported in the literature up to now. In this article, topology optimization was utilized to determine optimal topological patterns of non-pneumatic tyres in the design process, with the goal of matching the static stiffness of the current pneumatic tyres. Under this optimization formulation with weighted compliance and a volume constraint, several different patterns were obtained depending on the number of sections, volume fraction, and weighting factors. Among them, three representative patterns were chosen and analysed for possible applications under working conditions. This article proposes a systematic and efficient tool for designing the topological patterns of non-pneumatic tyres.

  13. An investigation of the effects of pneumatic actuator design on slip control for heavy vehicles

    NASA Astrophysics Data System (ADS)

    Miller, Jonathan I.; Cebon, David

    2013-01-01

    Progress in reducing actuator delays in pneumatic brake systems is opening the door for advanced anti-lock braking algorithms to be used on heavy goods vehicles. However, little has been published on slip controllers for air-braked heavy vehicles, or the effects of slow pneumatic actuation on their design and performance. This paper introduces a sliding mode slip controller for air-braked heavy vehicles. The effects of pneumatic actuator delays and flow rates on stopping performance and air (energy) consumption are presented through vehicle simulations. Finally, the simulations are validated with experiments using a hardware-in-the-loop rig. It is shown that for each wheel, pneumatic valves with delays smaller than 3 ms and orifice diameters around 8 mm provide the best performance.

  14. Structure design and experimental research on the electric-pneumatic transfer device with piezoelectric actuator

    NASA Astrophysics Data System (ADS)

    Li, Dong-Ming; Sun, Bao-yuan; Wang, Wei; Jia, Ying

    2008-10-01

    Electric-pneumatic transducer and electric-pneumatic positional valve has advantages of fire protection, explosion protection and lifetime dilatation etc, and are widely used in industrial automatic production. In this paper, two new electric-pneumatic transfer device with piezoelectric actuator whose structure and operating principle are proposed. One is based on the principle of nozzle-flapper, the other is based on opening-closing. Experiment research was carried on and the results show that the new transfer devices can meet requirement of air pressure output between 0.02MPa and 0.1MPa in industrial field with low voltage, which provides good basis of development of electric-pneumatic transducer valve with new piezoelectric structure.

  15. Costs and benefits of pneumatic collection in three specific New York City cases

    SciTech Connect

    Miller, Benjamin; Spertus, Juliette; Kamga, Camille

    2014-11-15

    Highlights: • Pneumatic and truck collection were compared in three New York City locations. • Relative costs, energy use, and greenhouse gas emissions varied significantly. • Variations were due to location-specific factors (e.g., route density, truck type). • Under appropriate conditions, pneumatic collection reduces TMT, BTU, and GHG. • Pneumatic capex may be offset by operating savings and externality benefits. - Abstract: Truck-based collection of municipal solid waste imposes significant negative externalities on cities and constrains the efficiency of separate collection of recyclables and organics and of unit-price-based waste-reduction systems. In recent decades, hundreds of municipal-scale pneumatic collection systems have been installed in Europe and Asia. Relatively few prior studies have compared the economic or environmental impacts of these systems to those of truck collection. A critical factor to consider when making this comparison is the extent to which the findings reflect the specific geographic, demographic, and operational characteristics of the systems considered. This paper is based on three case studies that consider the specific characteristics of three locations, comparing pneumatic systems with conventional collection on the basis of actual waste tonnages, composition, sources, collection routes, truck trips, and facility locations. In one case, alternative upgrades to an existing pneumatic system are compared to a potential truck-collection operation. In the other cases, existing truck operations are compared to proposed pneumatic systems which, to reduce capital costs, would be installed without new trenching or tunneling through the use of existing linear infrastructure. For the two proposed retrofit pneumatic systems, up to 48,000 truck kilometers travelled would be avoided and energy use would be reduced by up to 60% at an incremental cost of up to $400,000 USD per year over the total operating-plus-capital cost of

  16. Pneumatic Compression, But Not Exercise, Can Avoid Intradialytic Hypotension: A Randomized Trial.

    PubMed

    Álvares, Valeria R C; Ramos, Camila D; Pereira, Benedito J; Pinto, Ana Lucia; Moysés, Rosa M A; Gualano, Bruno; Elias, Rosilene M

    2017-01-01

    Conventional hemodialysis (HD) is associated with dialysis-induced hypotension (DIH) and ineffective phosphate removal. As the main source of extracellular fluid removed during HD are the legs, we sought to reduce DIH and increase phosphate removal by using cycling and pneumatic compression, which would potentially provide higher venous return, preserving central blood flow and also offering more phosphate to the dialyzer. We evaluated 21 patients in a randomized crossover fashion in which each patient underwent 3 different HD: control; cycling exercise during the first 60 min; and pneumatic compression during the first 60 min. Data obtained included bioelectrical impedance, hourly blood pressure measurement, biochemical parameters, and direct quantification of phosphate through the dialysate. DIH was defined as a drop in mean arterial pressure (MAP) ≥20 mm Hg. There was no difference in the ultrafiltration rate (p = 0.628), delta weight (p = 0.415), delta of total, intra and extracellular body water among the control, cycling, and pneumatic compression (p = 0.209, p = 0.348, and p = 0.467 respectively). Delta MAP was less changed by pneumatic compression when compared to control, cycling, and pneumatic compression respectively (-4.7 [-17.2, 8.2], -4.7 [-20.5, -0.2], and -2.3 [-8.1, 9.0] mm Hg; p = 0.021). DIH occurred in 43, 38, and 24% of patients in control, cycling, and pneumatic compression respectively (p = 0.014). Phosphate removal did not increase in any intervention (p = 0.486). Higher phosphate removal was dependent on ultrafiltration, pre dialysis serum phosphate, and higher parathyroid hormone. Pneumatic compression during the first hour of dialysis was associated with less DIH, albeit there was no effect on fluid parameters. Neither exercise nor pneumatic compression increased phosphate removal. © 2017 S. Karger AG, Basel.

  17. Intermittent pneumatic compression of legs increases microcirculation in distant skeletal muscle.

    PubMed

    Liu, K; Chen, L E; Seaber, A V; Johnson, G W; Urbaniak, J R

    1999-01-01

    Intermittent pneumatic compression has been established as a method of clinically preventing deep vein thrombosis, but the mechanism has not been documented. This study observed the effects of intermittent pneumatic compression of legs on the microcirculation of distant skeletal muscle. The cremaster muscles of 80 male rats were exposed, a specially designed intermittent pneumatic-compression device was applied to both legs for 60 minutes, and the microcirculation of the muscles was assessed by measurement of the vessel diameter in three categories (10-20, 21-40, and 41-70 microm) for 120 minutes. The results showed significant vasodilation in arterial and venous vessels during the application of intermittent pneumatic compression, which disappeared after termination of the compression. The vasodilation reached a maximum 30 minutes after initiation of the compression and could be completely blocked by an inhibitor of nitric oxide synthase, NG-monomethyl-L-arginine (10 micromol/min). A 120-minute infusion of NG-monomethyl-L-arginine, beginning coincident with 60 minutes of intermittent pneumatic compression, resulted in a significant decrease in arterial diameter that remained at almost the same level after termination of the compression. The magnitude of the decrease in diameter in the group treated with intermittent pneumatic compression and NG-monomethyl-L-arginine was comparable with that in the group treated with NG-monomethyl-L-arginine alone. The results imply that the production of nitric oxide is involved in the positive influence of intermittent pneumatic compression on circulation. It is postulated that the rapid increase in venous velocity induced by intermittent pneumatic compression produces strong shear stress on the vascular endothelium, which stimulates an increased release of nitric oxide and thereby causes systemic vasodilation.

  18. Experimental study on wavy-flow pneumatic conveying in horizontal pipe

    NASA Astrophysics Data System (ADS)

    Xu, Hua; Liu, Shi; Wang, Haigang; Jiang, Fan

    2002-05-01

    Low-velocity pneumatic conveying systems have been developed to meet the requirement of low operation costs and have been widely used in chemical and process industries. However, the understanding of the mechanism is limited. This paper reports an experimental study on a slug-flow pneumatic conveying. Electrical capacitance tomography has been used to visualize plug shape and identify the flow pattern. Comparison was made between the experimental data of pressure drop with existed models.

  19. Development of Pneumatic Robot Hand and Construction of Master-Slave System

    NASA Astrophysics Data System (ADS)

    Tsujiuchi, Nobutaka; Koizumi, Takayuki; Nishino, Shinya; Komatsubara, Hiroyuki; Kudawara, Tatsuwo; Hirano, Masanori

    Recently, research and development has focused on robots that work in place of people. It is necessary for robots to perform the same flexible motions as people. Additionally, such robots need to incorporate high-level safety features in order not to injure people. For creation of such robots, we need to develop a robot hand that functions like a human hand. At the same time, this type of robot hand can be used as an artificial hand. Here, we present artificial muscle-type pneumatic actuators as the driving source of a robot hand that is both safe and flexible. Some development of robot hands using pneumatic actuators has already taken place. But, until now, when a pneumatic actuator is used, a big compressor is needed. So, the driving system also needs to be big; enlargement of the driving system is a major problem. Consequently, in this research, we develop a low-pressure, low-volume pneumatic actuator for driving a robot hand that works flexibly and safely on the assumption that it will be in contact with people. We develop a five-fingered robot hand with pneumatic actuators. And, we construct a master-slave system to enable the robot hand to perform the same operations as a human hand. We make a 1-link arm that has one degree of freedom using a pneumatic actuator, and construct a control system for the 1-link arm and verify its control performance.

  20. Comparison of ultrasonic and pneumatic intracorporeal lithotripsy techniques during percutaneous nephrolithotomy.

    PubMed

    Karakan, Tolga; Diri, Akif; Hascicek, Ahmet Metin; Ozgur, Berat Cem; Ozcan, Serkan; Eroglu, Muzaffer

    2013-01-01

    To compare the effectiveness and safety of ultrasonic and pneumatic lithotripters in the treatment of renal stone disease. A total of 227 consecutive percutaneous nephrolithotomy procedures for renal calculi were performed. In 107 patients ultrasonic lithotriptors were used (group I) and in 83 patients pneumatic lithotriptors were used (group II). In the remaining 37 patients, stones were managed with both pneumatic and ultrasonic lithotripters. Follow-up studies included intravenous urography (IVU) and/or computed tomography (CT). The mean operative time and duration of hospitalization were similar between the groups. In the ultrasonic treatment group, 100 (96.9%) patients were stone-free on postoperative day 1 and 5 (4.6%) went on to undergo an additional treatment modality, resulting in a total stone-free rate of 97.2%. In the pneumatic lithotripsy group, 68 (81.9%) patients were stone-free after the primary procedure on the first day and 15 (18.1%) went on to undergo an additional treatment modality, resulting in a stone-free rate of 91.5%. The final stone-free rates at 3 months postoperatively in groups I, II, and III were 97.2%, 91.5%, and 87.9%, respectively (P = 0.826). We conclude that both ultrasonic and pneumatic lithotripters are effective and safe for intracorporeal lithotripsy. However, the ultrasonic lithotripter provides higher stone-free rates with similar morbidity compared with pneumatic devices.

  1. Evaluation of Models of Pneumatic Tourniquet in Simulated Out-of-Hospital Use.

    PubMed

    Kragh, John F; Aden, James K; Dubick, Michael A

    2016-01-01

    Pneumatic field tourniquets have been recommended for Military medics to stop bleeding from limb wounds, but no comparison of commercially available pneumatic models of tourniquet has been reported. The purpose of this study is to provide laboratory data on the differential performance of models of pneumatic tourniquets to inform decision-making of potential field assessment by military users. Models included the Emergency and Military Tourniquet (EMT), Tactical Pneumatic Tourniquet 2-inch (TPT2), and Tactical Pneumatic Tourniquet 3-inch (TPT3). One user tested the three tourniquet models 30 times each on a manikin to collect data on effectiveness (yes-no bleeding control), pulse cessation, time to stop bleeding, total time of application, after time (after bleeding was stopped), pressure applied, blood loss volume, composite outcome (whether all individual outcomes were good or not), and pump count of the bulb used to inflate the tourniquet. Neither tourniquet effectiveness nor pulse cessation (ρ = 1; likelihood ratio, 0 for both) differed among tourniquet models: all three models had 100% (30 of 30 tests) for both outcomes. The EMT had the best or tied for best performance in time to stop bleeding, total time, after time, pressure blood loss, composite outcome, and pump count. Each of the three models of pneumatic field tourniquet was 100% effective in stopping simulated bleeding. Among the three models, the EMT showed the best or tied for best performance in time to stop bleeding, blood loss, and composite outcomes. All models are suitable for future field assessment among military users. 2016.

  2. Intussusception patients older than 1 year tend to have early recurrence after pneumatic enema reduction.

    PubMed

    Wang, Zhe; He, Qiu-ming; Zhang, Hong; Zhong, Wei; Xiao, Wei-qiang; Lu, Lian-wei; Yu, Jia-kang; Xia, Hui-min

    2015-09-01

    To identify age risk factors of early recurrent intussusception after pneumatic enema reduction. Management opinions are proposed. Two thousand two hundred and ninety-five intussusception patients' medical records from January 2009 to December 2011 were retrospectively reviewed and analyzed. Of the 2295 patients, the intussusception of 1917 of them was initially reduced by pneumatic enema, with 127 cases recurring within 72 h. The early recurrence rate is 6.62%. The early recurrence rate of patients younger than 1 year old is 2.1% (22/1032), while the rate for those older than 1 year is 11.9% (105/885). The difference is significant (P = 0.0001). There were no significant differences between age groups older than 1 year. One hundred and seventeen cases of recurrence happened within 48 h, which accounted for 92.1% of all early recurrence. Recurrence patients were treated again with pneumatic enema, with a successful reduction in 93.7%. They were followed up for 2-4 years; the long-term recurrent rate was 11.8% (14/119). No patient had poor prognosis because of delayed treatment. Intussusception patients older than 1 year tend to have greater early recurrence rate after pneumatic enema reduction; 92.1% of the early recurrent cases happened in 48 h. There is no need to hospitalize patients after pneumatic enema reduction. A repeat pneumatic enema is a good choice before surgical approach.

  3. [The forensic medical characteristics of the entrance bullet holes created by the shots from pneumatic rifles].

    PubMed

    Legin, G A; Bondarchuk, A O; Perebetjuk, A N

    2015-01-01

    The objective of the present study was to compare the injurious action of three types of the bullets for the pneumatic weapons shot from different distances using the Gamo pump air pistol and the BAM B22-1 pneumatic rifle. The following four kinds of the bullets were tested: "the fireball", "Luman cap 0.3", "Luman Field Target 0.68" and "DIABOLO". It was experimentally shown that the injurious action of the bullets fired from the same distance from the pneumatic weapons depends on the type of both the bullet and the weapon, as well as the properties of the target material. Specifically, the action of bullets fired from the piston pneumatic rifle remained stable whereas that of the bullets shot from the gas-balloon air pistol decreased as the gas was exhausted. The studies by the contact-diffusion method have demonstrated that the entrance bullet holes created by the shots from pneumatic weapons are surrounded by dispersed metal particles which makes it possible to estimate the shooting distance. Moreover, the bullets fired from the pneumatic weapons leave the muzzle face imprint on certain target materials.

  4. [The classification of the injuries inflicted to the human body by gunshots from the pneumatic weapons].

    PubMed

    Kozachenko, I N

    2016-01-01

    The classification of the injuries inflicted to the human body by gunshots from the pneumatic weapons remains to be developed. The objective of the present work was to elaborate the classification of the injuries caused by gunshots from the pneumatic weapons based on the analysis of 98 expert and acts of forensic medical expertises (surveys) of living subjects (n=76) and corpses (n=22) affected by gunshots from the pneumatic weapons. These materials were collected from the bureaus of forensic medical expertise in different regions of the Ukraine during the period from 2006 till 2015. In addition, scientific publications concerned with the problem of interest were used along with the relevant explanatory and terminological dictionaries. The terminology and the conceptual framework proposed by the author in the earlier papers provided a basis for the development of the first standard classification of the injuries inflicted to the human body by gunshots from the pneumatic weapons categorized into 15 groups. It is believed that this classification will lay the foundation for the common approach of forensic medical experts to the examination and analysis of the data on the gunshots from the pneumatic weapons used to be found on the bodies of living subjects and the corpses. Moreover, it may be useful for the clinicians in their diagnostic and therapeutic practices and for the legal practitioners engaged in the quality assessment of the results of forensic medical expertises. It is recommended to present information about the gunshots from the pneumatic weapons in the accounting documents in a separate line.

  5. Pneumatic motor powered Thrust Vector Control (TVC) for liquid propelled launch vehicles

    NASA Astrophysics Data System (ADS)

    Malone, Mark C.; Evans, P. S.

    1992-02-01

    Recent studies performed for the Titan 4 launch vehicle indicate significant potential advantages in replacing the current stage 1 and 2 recirculating hydraulic TVC (thrust vector control) system with a PMA (pneumatic mechanical actuation) system. Some of the advantages of a PMA system over the recirculating hydraulic system include reduced part count and weight, reduced maintenance and life-cycle cost, and improved mission reliability. PMA technology, used in aircraft applications since the 1960s, is well suited in launch vehicle TVC applications where an existing pneumatic pressure source is available. A typical pneumatic motor TVC consists of a pneumatic power source, a dual rotor pneumatic motor, a gear box, a ball screw actuator, and the associated closed-loop servo-control elements. One key issue with implementing this mechanical approach is designing a TVC system to withstand large load transient disturbances during liquid engine starting. Hydraulic actuator transient loads have exceeded 60,000 lb(sub f) for a 30,000 lb(sub f) stall design actuator during ground starts of the Titan 3B, Stage 1 engine. A PMA TVC system must also withstand these start transients without imparting excessive reaction loads to the engine nozzle and thrust structure. Work completed to date with Martin Marietta to examine pneumatic motor powered TVC options and technology benefits is presented. The load transient issue is discussed along with potential solutions and the associated trades. General background on PMA technology and experience base is also presented.

  6. Antibody immobilization using pneumatic spray: comparison with the avidin-biotin bridge immobilization method.

    PubMed

    Figueroa, Jhon; Magaña, Sonia; Lim, Daniel V; Schlaf, Rudy

    2012-12-14

    The formation of a thin antibody film on a glass surface using pneumatic spray was investigated as a potential immobilization technique for capturing pathogenic targets. Goat-Escherichia coli O157:H7 IgG films were made by pneumatic spray and compared against the avidin-biotin bridge immobilized films by assaying with green fluorescent protein (GFP) transformed E. coli O157:H7 cells and fluorescent reporter antibodies. Functionality, stability, and immobilization of the films were tested. The pneumatic spray films had lower fluorescence intensity values than the avidin-biotin bridge films but resulted in similar detection for E. coli O157:H7 at 10(5)-10(7)cells/ml sample concentrations with no detection of non-E. coli O157:H7 strains. Both methods also resulted in similar percent capture efficiencies. The results demonstrated that immobilization of antibody via pneumatic spray did not render the antibody non-functional and produced stable antibody films. The amount of time necessary for immobilization of the antibody was reduced significantly from 24h for the avidin-biotin bridge to 7 min using the pneumatic spray technique, with additional benefits of greatly reduced use of materials and chemicals. The pneumatic spray technique promises to be an alternative for the immobilization of antibodies on glass slides for capturing pathogenic targets and use in biosensor type devices. Copyright © 2012. Published by Elsevier B.V.

  7. Field and numerical determinations of pneumatic flow parameters of unsaturated fractured porous rocks on various scales

    NASA Astrophysics Data System (ADS)

    Guillon, S.; Vu, M. T.; Pili, E.; Adler, P. M.

    2013-05-01

    Air permeability is measured in the fractured crystalline rocks of the Roselend Natural Laboratory (France). Single-hole pneumatic injection tests as well as differential barometric pressure monitoring are conducted on scales ranging from 1 to 50 m, in both shallow and deep boreholes, as well as in an isolated 60 m3 chamber at 55 m depth. The field experiments are interpreted using numerical simulations in equivalent homogeneous porous media with their real 3-D geometry in order to estimate pneumatic parameters. For pneumatic injection tests, steady-state data first allow to estimate air permeability. Then, pressure recovery after a pneumatic injection test allows to estimate the air-filled porosity. Comparison between the various studied cases clarifies the influence of the boundary conditions on the accuracy of the often used 1-D estimate of air permeability. It also shows that permeabilities correlate slightly with fracture density. In the chamber, a 1 order-of-magnitude difference is found between the air permeabilities obtained from pneumatic injection tests and from differential barometric pressure monitoring. This discrepancy is interpreted as a scale effect resulting from the approximation of the heterogeneous fractured rock by a homogeneous numerical model. The difference between the rock volumes investigated by pneumatic injection tests and by differential barometric pressure monitoring may also play a role. No clear dependence of air permeability on saturation has been found so far.

  8. INFECTIOUS MYXOMATOSIS OF RABBITS

    PubMed Central

    Rivers, Thomas M.; Ward, S. M.

    1937-01-01

    From the results of the experiments described in this paper it is obvious that large amounts of elementary bodies of myxoma can be obtained in a relatively pure state by means of the methods used. Furthermore, it is evident that infectious myxomatosis is a viral disease in which elementary bodies of the same order of magnitude as vaccinal elementary bodies play a conspicuous rô1e in that they either represent the etiological agent or are intimately associated with it. The bodies are specifically agglutinated by antimyxoma serum and are agglutinated to a less extent by serum from rabbits convalescing from fibroma, a disease closely related to myxoma. In virus-free filtrates of emulsions prepared from infected skin there is a soluble precipitinogen or precipitinogens specific for the malady. Moreover, a specific precipitinogen or precipitinogens are demonstrable in virus-free serum of animals acutely ill as a result of extensive infection with myxoma virus. It is believed that this is the second viral disease, yellow fever (14) being the first, in which a specific soluble antigen free from virus has been found in the serum of ill animals. PMID:19870643

  9. Possible postcranial pneumaticity in the last common ancestor of birds and crocodilians: evidence from Erythrosuchus and other Mesozoic archosaurs.

    PubMed

    Gower, D J

    2001-03-01

    Birds and crocodilians (extant archosaurs) have differing, distinctive morphologies. Birds have respiratory airsacs with diverticula that pneumatize the postcranial skeleton, a feature absent in crocodilians. Bony correlates of pneumatic sinuses are known in the vertebrae of some non-avian dinosaurs and in pterosaurs--taxa more closely related to birds than crocodilians. This and the apparent absence of pneumatic postcranial bones in fossil archosaurs more closely related to crocodilians than to birds, has been interpreted as evidence that postcranial pneumaticity is a derived character of birds and their nearest fossil relatives. The presence of apparent osteological correlates of postcranial pneumaticity is here reported in some non-crown-group archosaurs, and some of the fossil taxa more closely related to crocodilians than to birds. This suggests that the last common ancestor of birds and crocodilians might have had a pneumatized postcranium, and that the absence of this feature in crocodilians might be derived.

  10. Possible postcranial pneumaticity in the last common ancestor of birds and crocodilians: evidence from Erythrosuchus and other Mesozoic archosaurs

    NASA Astrophysics Data System (ADS)

    Gower, D. J.

    2001-02-01

    Birds and crocodilians (extant archosaurs) have differing, distinctive morphologies. Birds have respiratory airsacs with diverticula that pneumatize the postcranial skeleton, a feature absent in crocodilians. Bony correlates of pneumatic sinuses are known in the vertebrae of some non-avian dinosaurs and in pterosaurs - taxa more closely related to birds than crocodilians. This and the apparent absence of pneumatic postcranial bones in fossil archosaurs more closely related to crocodilians than to birds, has been interpreted as evidence that postcranial pneumaticity is a derived character of birds and their nearest fossil relatives. The presence of apparent osteological correlates of postcranial pneumaticity is here reported in some non-crown-group archosaurs, and some of the fossil taxa more closely related to crocodilians than to birds. This suggests that the last common ancestor of birds and crocodilians might have had a pneumatized postcranium, and that the absence of this feature in crocodilians might be derived.

  11. Acute Radiation Hypotension in the Rabbit: a Model for the Human Radiation Shock Syndrome.

    NASA Astrophysics Data System (ADS)

    Makale, Milan Theodore

    This study has shown that total body irradiation (TBI) of immature (40 to 100 day old) rabbits leads to an acute fall in mean arterial pressure (MAP) 30 to 90 minutes after exposure, which takes no more than about three minutes, and often results in pressures which are less than 50% of the lowest pre-exposure MAP. This is termed acute cardiovascular collapse (ACC). ACC is often accompanied by ECG T-wave elevation, a sharp rise in ear temperature, labored breathing, pupillary constriction, bladder emptying, and loss of abdominal muscle tone. About 73% of 40 to 100 day rabbits exhibit ACC; the others and most older rabbits display gradual pressure reductions (deliberate hypotension) which may be profound, and which may be accompanied by the same changes associated with ACC. ACC and deliberate hypotension occurred in rabbits cannulated in the dorsal aorta, and in non-operated animals. The decline in MAP for all 40 to 100 day cannulated rabbits (deliberate and ACC responders) is 55.4%. The experiments described below only involved 40 to 100 day cannulated TBI rabbits. Heart region irradiation resulted in an average MAP decline of 29.1%, with 1/15 rabbits showing ACC. Heart shielding during TBI reduced the decline in MAP to 19%, with 1/10 rabbits experiencing ACC. These results imply that the heart region, which includes the heart, part of the lungs, neural receptors, roots of the systemic vessels, and the blood, is a sensitive target. Bilateral vagotomy reduced the decline in MAP to 24.9%, and abolished ACC. Atropine (6 mg/kg) reduced the frequency of ACC to 26%, and the decline in MAP to 41.4%. In 11/13 rabbits the voltage generated by left vagal transmission rose after TBI. The vagi appear to participate in radiation hypotension. Heart shielding together with bilateral vagotomy reduced the decline in MAP to only 9.9%, with no ACC responders. The mean right ventricular pressure (MRVP) rose after TBI in 8/10 rabbits. In animals which displayed either ACC or steep

  12. Late effects from particulate radiations in primate and rabbit tissues

    NASA Technical Reports Server (NTRS)

    Lett, J. T.; Cox, A. B.; Bergtold, D. S.; Lee, A. C.; Pickering, J. E.

    1984-01-01

    In connection with studies regarding the hazards posed by ionizing radiations to man in space, the U.S. Air Force conducted an experiment about 20 years ago. In this experiment a large number of young rhesus monkeys was exposed to proton fluxes similar to those to be anticipated during solar flares. After irradiation, the animals were kept at the USAF School of Aerospace Medicine in Texas. The monkeys have been employed in investigations concerning aspects of late radiation damage. These investigations are discussed, taking into account the propagation of fibroblasts from irradiated monkeys. The results of the investigations are evaluated, giving attention also to experiments with white rabbits. It is found that, except in the case of major solar flares, when acute radiation damage could lead quickly to death, the hazards to astronauts from space radiations arise from such debilitating late effects as cataracts, damage to the central nervous system and benign tumors, and life-threatening neoplasia.

  13. Late effects from particulate radiations in primate and rabbit tissues

    NASA Technical Reports Server (NTRS)

    Lett, J. T.; Cox, A. B.; Bergtold, D. S.; Lee, A. C.; Pickering, J. E.

    1984-01-01

    In connection with studies regarding the hazards posed by ionizing radiations to man in space, the U.S. Air Force conducted an experiment about 20 years ago. In this experiment a large number of young rhesus monkeys was exposed to proton fluxes similar to those to be anticipated during solar flares. After irradiation, the animals were kept at the USAF School of Aerospace Medicine in Texas. The monkeys have been employed in investigations concerning aspects of late radiation damage. These investigations are discussed, taking into account the propagation of fibroblasts from irradiated monkeys. The results of the investigations are evaluated, giving attention also to experiments with white rabbits. It is found that, except in the case of major solar flares, when acute radiation damage could lead quickly to death, the hazards to astronauts from space radiations arise from such debilitating late effects as cataracts, damage to the central nervous system and benign tumors, and life-threatening neoplasia.

  14. RABBIT ANTIBODIES TO STREPTOCOCCAL CARBOHYDRATES

    PubMed Central

    Braun, Dietmar G.; Eichmann, Klaus; Krause, Richard M.

    1969-01-01

    In a search for possible genetic factors which may influence the immune response to the streptococcal carbohydrates, over 100 rabbits have been immunized with streptococcal vaccines, and representative examples of high and low response pairs mated. The concentration of precipitins to the group—specific carbohydrates has been measured in the antisera following primary intravenous immunization with heat-killed streptococcal vaccines, Group A, Group A-variant, and Group C. For the majority of rabbits, the concentration of precipitins varied between 1 and 10 mg/ml of antiserum; while in the minority, it was between 11 and 32 mg/ml. The offspring of rabbits with high antibody levels had a significantly higher concentration of antibody than was seen in the offspring of rabbits of low response parents. Such data suggest that the magnitude of the immune response to these carbohydrate antigens is under some form of genetic control. Not uncommonly in rabbits with hyper-γ-globulinemia following primary immunization, the group-specific precipitins are the predominant component of the γ-globulin. An unusual feature of such components is that they are electrophoretically monodisperse, and possess individual antigenic specificity. In this respect they resemble the myeloma proteins. When a response of this sort is not seen after primary immunization, it may occur after secondary immunization. Therefore, prior exposure to the same or closely related antigen may also have an influence on the occurrence of high concentrations of such uniform antibodies. PMID:5766948

  15. Ciliary body PDT in pigmented rabbit eyes: effect of single and repeated treatment.

    PubMed

    Tsilimbaris, M K; Naoumidi, I I; Kozombolis, V P; Naoumidi, T L; Daskalakis, M; Pallikaris, I G

    2000-06-01

    To investigate the morphologic and hypotensive effect of contact transscleral ciliary body PDT in pigmented rabbit eyes. The right eyes of 33 pigmented rabbits were irradiated using chloraluminum sulfonated phthalocyanine as photosensitizer and a diode laser (670 nm) as the light source. Twenty-five animals received a single treatment. Eight animals received a second treatment 13 days after the first one. Photosensitizer was administered by means of continuous intravenous infusion. Ciliary body was irradiated transsclerally by means of an optic fiber applied on the corneoscleral limbus. In all cases 14-16 laser applications were performed to cover 360 degrees of the ciliary body. Animals were followed for a maximum of 30 days by means of tonometry and biomicroscopy. Retreatments were performed using the same irradiation protocol. At the end of the follow up time animals were sacrificed and their were eyes prepared for light and electron microscopy. Transscleral ciliary body PDT resulted in significant but temporary reduction of IOP in all cases. The effect lasted about two weeks. Retreatment led to a new significant drop of the IOP, which lasted about two weeks again. In histological examination the initial effect was vascular thrombosis, followed by edema and disintegration of the ciliary epithelial layers. In all cases the appearance of the ciliary body had returned to normal 15 days after irradiation. Contact transscleral PDT with the treatment parameters used in this study results in significant but temporary functional and morphological alteration in pigmented rabbits ciliary body.

  16. Experimental model of cutaneous radiation injury in rabbits.

    PubMed

    Meirelles, Rafael Panisi de Campos; Hochman, Bernardo; Helene Junior, Americo; Lellis, Rute; Fraga, Murillo Francisco Pires; Ferreira, Lydia Masako

    2013-11-01

    To describe an experimental model of cutaneous radiation injury in rabbits. On this study eight six-month-old New Zealand male rabbits, with an average weight of 2.5 kg were used. They were distributed in four groups (n=2 per group). The control group did not receive radiotherapy and the others received one radiotherapy session of 2000, 3000 and 4500 cGy, respectively. Photographic analysis and histopathological evaluation of the irradiated areas were carried out. After 30 days, the animals from the control group had all their hair grown. In spite of that, the animals from group 2000 cGy had a 60-day alopecia and from group 3000 cGy, a 90-day alopecia. After the 30th day, the 3000 cGy group demonstrated 90-day cutaneous radiation injuries, graded 3 and 4. One of the animals from group 4500 cGy died on the 7th day with visceral necrosis. The other from the same group had total skin necrosis. A progressive reduction of glands and blood vessels count and an increase on collagen deposition was observed. The proposed experimental model is reproductable. This study suggests that the dosage 4500 cGy is excessive and the 3000 cGy is the most effective for this experimental model of cutaneous radiation injury in rabbits.

  17. Efficacy of Pneumatic Dilatation in Saudi Achalasia Patients

    PubMed Central

    Aljebreen, Abdulrahman M.; Samarkandi, Sara; Al-Harbi, Tahani; Al-Radhi, Haifa; Almadi, Majid A

    2014-01-01

    Background/Aims: Pneumatic dilatation (PD) is one of the effective treatments of achalasia. The aim of this study was to evaluate the efficacy of pneumatic dilation and patient satisfaction in Saudi achalasia patients. Patients and Methods: We have retrospectively recruited patients with confirmed achalasia, who underwent at least one dilatation session from January 1990 to January 2010 at a single tertiary center. Symptoms, including weight loss, dysphagia, retrosternal pain, and regurgitation, were assessed with the use of the Eckardt score (which ranges from 0 to 12, with higher scores indicating more pronounced symptoms). All patients were called and asked about their Eckardt score in addition to their satisfaction score post the dilatation procedure. The primary outcome was therapeutic success (Eckardt score ≤ 3) and patient satisfaction at the time of their calls. The secondary outcomes included the need for retreatment and the rate of complications. Results: A total of 29 patients were included, with a mean age of 40.30 (95% CI: 36.1-44.6) and 55.2% of them were males. The mean of the pre-dilatation Eckardt score was 8.3 (95% CI: 7.2-9.4), which dropped to 2.59 (95% CI: 1.7-3.5) after PD (P < 0.01) with a clinical remission of 76.7% after the first dilatation and a total failure in two patients (7%) after the third dilatation. The mean number of dilatations was 1.3 (95% CI: 1.1-1.5) where 50.7% required one dilatation, 19.2% required two dilatations, and 30.1% required three dilatations. The mean of the symptoms-free period was 53.4 months (SD 52.7, range 1-180) with symptoms recurring in 35% of patients within 2 years. The mean of post-PD patient satisfaction was 7.45 (95% CI: 6.2-8.7). Perforation, which was treated conservatively, occurred in one patient (3.5%), whereas bleeding occurred in two patients (7%). Age or gender was not found to be a predictor of Eckardt score improvement on multivariate linear regression analysis. Conclusion: PD is an

  18. Pneumatic artificial muscle actuators for compliant robotic manipulators

    NASA Astrophysics Data System (ADS)

    Robinson, Ryan Michael

    Robotic systems are increasingly being utilized in applications that require interaction with humans. In order to enable safe physical human-robot interaction, light weight and compliant manipulation are desirable. These requirements are problematic for many conventional actuation systems, which are often heavy, and typically use high stiffness to achieve high performance, leading to large impact forces upon collision. However, pneumatic artificial muscles (PAMs) are actuators that can satisfy these safety requirements while offering power-to-weight ratios comparable to those of conventional actuators. PAMs are extremely lightweight actuators that produce force in response to pressurization. These muscles demonstrate natural compliance, but have a nonlinear force-contraction profile that complicates modeling and control. This body of research presents solutions to the challenges associated with the implementation of PAMs as actuators in robotic manipulators, particularly with regard to modeling, design, and control. An existing PAM force balance model was modified to incorporate elliptic end geometry and a hyper-elastic constitutive relationship, dramatically improving predictions of PAM behavior at high contraction. Utilizing this improved model, two proof-of-concept PAM-driven manipulators were designed and constructed; design features included parallel placement of actuators and a tendon-link joint design. Genetic algorithm search heuristics were employed to determine an optimal joint geometry; allowing a manipulator to achieve a desired torque profile while minimizing the required PAM pressure. Performance of the manipulators was evaluated in both simulation and experiment employing various linear and nonlinear control strategies. These included output feedback techniques, such as proportional-integral-derivative (PID) and fuzzy logic, a model-based control for computed torque, and more advanced controllers, such as sliding mode, adaptive sliding mode, and

  19. European Rabbits as Reservoir for Coxiella burnetii

    PubMed Central

    González-Barrio, David; Maio, Elisa; Vieira-Pinto, Madalena

    2015-01-01

    We studied the role of European rabbits (Oryctolagus cuniculus) as a reservoir for Coxiella burnetii in the Iberian region. High individual and population seroprevalences observed in wild and farmed rabbits, evidence of systemic infections, and vaginal shedding support the reservoir role of the European rabbit for C. burnetii. PMID:25988670

  20. HEREDITARY OSTEOPETROSIS OF THE RABBIT

    PubMed Central

    Pearce, Louise; Brown, Wade H.

    1948-01-01

    The manifestations and course of an hereditary disease of the rabbit are reported. The condition is present at birth and is invariably fatal, generally in the 4th and 5th weeks of age. Retardation and eventual cessation of growth with marked reduction in size are conspicuous characteristic symptoms. The condition, which first occurred in the backcross progeny of a pure bred Dutch male rabbit, is inherited. It is determined by the expression of a simple recessive unit factor, affected individuals being homozygous for the factor. Rabbits heterozygous for the factor are identified only by appropriate breeding tests. The condition is not sex-linked. The disease has a remarkable resemblance to osteopetrosis or marble bone disease of infants and children with respect to signs and general course and also, as may be stated in anticipation of later discussions (5, 6), to the characteristic abnormal condition of the skeleton. PMID:18103397

  1. Evaluation of pneumatic versus holmium:YAG laser lithotripsy for impacted ureteral stones.

    PubMed

    Binbay, Murat; Tepeler, Abdulkadir; Singh, Avinash; Akman, Tolga; Tekinaslan, Erdem; Sarilar, Omer; Baykal, Murat; Muslumanoglu, Ahmet Yaser

    2011-12-01

    We prospectively analyzed and compared the effectiveness and complications of pneumatic lithotripter with a holmium:yttrium-aluminum-garnet (Ho:YAG) laser for the ureterorenoscopic management of impacted ureteral stones. From January 2006 to January 2008, we performed retrograde endoscopic treatment in 288 patients with ureteral stones in our clinic. The patients with impacted stones were randomized into two groups according to the lithotripter used to fragment the stone: pneumatic (n = 40) and laser (n = 40). The preoperative, operative, and post-operative follow-up findings were analyzed and compared. The average stone size was similar in both groups (118.8 ± 58.3 mm(2) vs. 110.7 ± 54.4 mm(2)). The calculi were located in the distal ureter in most of the patients in both groups (65% in pneumatic group and 52.5% in laser group). The operation time was significantly diminished in the laser group (P = 0.001). The stone-free rates after a single ureteroscopic procedure were 80 and 97.5% in the pneumatic and laser groups, respectively (P = 0.03). Auxiliary treatments were needed in seven patients in the pneumatic group, while only one patient in the laser group (P = 0.05) needed this treatment. After the additional procedures, a 100% success rate was achieved in both groups. The rate of double J stent insertion was significantly higher in the pneumatic group (P = 0.01). In the pneumatic group, four cases of stone up-migration and one case of post-operative stricture were seen, whereas only one case of stone up-migration was noted in the laser group. Our comparative study has shown that the use of Ho:YAG as an intracorporeal lithotripter during ureteroscopic management of impacted ureteral stones is highly efficient with high success rates, regardless of the stone location.

  2. A randomized trial of pneumatic reduction versus hydrostatic reduction for intussusception in pediatric patients.

    PubMed

    Xie, Xiaolong; Wu, Yang; Wang, Qi; Zhao, Yiyang; Chen, Guobin; Xiang, Bo

    2017-08-08

    Data of randomly controlled trials comparing the hydrostatic and pneumatic reduction for intussusception in pediatric patients as initial therapy are lacking. The aim of this study was to conduct a randomly controlled trial to compare the effectiveness and safety of the hydrostatic and pneumatic reduction techniques. All intussusception patients who visited West China Hospital of Sichuan University from January 2014 to December 2015 were enrolled in this study in which they underwent pneumatic reduction or hydrostatic reduction. Patients were randomized into ultrasound-guided hydrostatic or X-ray-guided pneumatic reduction group. The data collected includes demographic data, symptoms, signs, and investigations. The primary outcome of the study was the success rate of reduction. And the secondary outcomes of the study were the rates of intestinal perforations and recurrence. A total of 124 children with intussusception who had met the inclusion criteria were enrolled. The overall success rate of this study was 90.32%. Univariable analysis showed that the success rate of hydrostatic reduction with normal saline (96.77%) was significantly higher than that of pneumatic reduction with air (83.87%) (p=0.015). Perforation after reduction was found in only one of the pneumatic reduction group. The recurrence rate of intussusception in the hydrostatic reduction group was 4.84% compared with 3.23% of pneumatic reduction group. Our study found that ultrasound-guided hydrostatic reduction is a simple, safe and effective nonoperative treatment for pediatric patients suffering from intussusceptions, and should be firstly adopted in the treatment of qualified patients. Therapeutic study TYPE OF STUDY: Prospective study. Copyright © 2017 Elsevier Inc. All rights reserved.

  3. Effect of acceleration forces during transport through a pneumatic tube system on ROTEM® analysis.

    PubMed

    Amann, Gerhard; Zehntner, Christine; Marti, Florian; Colucci, Giuseppe

    2012-03-09

    ROTEM® is considered a helpful point-of-care device to monitor blood coagulation in emergency situations. Centrally performed analysis is desirable but rapid transport of blood samples is an important prerequisite. The effect of acceleration forces on sample transport through a pneumatic tube system on ROTEM® should be tested at each institution to exclude a pre-analytical influence. The aims of the present work were: (i) to investigate the effect of pneumatic tube transport on ROTEM® parameters; (ii) to compare blood sample transport via pneumatic tube vs. manual transportation; and (iii) to determine the effect of acceleration forces on ROTEM® parameters. This is a single centre study with 20 healthy volunteers. Five whole blood samples were transferred to the central haematology laboratory by either normal transport or pneumatic delivery with different speed and acceleration forces. EXTEM, INTEM, FIBTEM and APTEM were analysed in parallel with two ROTEM® devices and compared. Acceleration forces were measured during transport with two different instruments. Increment of transport time, speed and distance resulted in an augmentation of acceleration forces and peaks. All results of the ROTEM® analysis after manual transport or pneumatic delivery were within normal range. However, increase in acceleration forces resulted in minimally but statistically significant changes in multiple ROTEM® parameters. The higher the acceleration forces, the more ROTEM® parameters are influenced. Acceleration forces during transport through a pneumatic tube system have an influence on ROTEM® parameters. Prior to transfer blood samples via pneumatic tube system these influences should be tested to exclude clinically relevant blood coagulation activation in vitro.

  4. Rod-based Fabrication of Customizable Soft Robotic Pneumatic Gripper Devices for Delicate Tissue Manipulation.

    PubMed

    Low, Jin-Huat; Yeow, Chen-Hua

    2016-08-02

    Soft compliant gripping is essential in delicate surgical manipulation for minimizing the risk of tissue grip damage caused by high stress concentrations at the point of contact. It can be achieved by complementing traditional rigid grippers with soft robotic pneumatic gripper devices. This manuscript describes a rod-based approach that combined both 3D-printing and a modified soft lithography technique to fabricate the soft pneumatic gripper. In brief, the pneumatic featureless mold with chamber component is 3D-printed and the rods were used to create the pneumatic channels that connect to the chamber. This protocol eliminates the risk of channels occluding during the sealing process and the need for external air source or related control circuit. The soft gripper consists of a chamber filled with air, and one or more gripper arms with a pneumatic channel in each arm connected to the chamber. The pneumatic channel is positioned close to the outer wall to create different stiffness in the gripper arm. Upon compression of the chamber which generates pressure on the pneumatic channel, the gripper arm will bend inward to form a close grip posture because the outer wall area is more compliant. The soft gripper can be inserted into a 3D-printed handling tool with two different control modes for chamber compression: manual gripper mode with a movable piston, and robotic gripper mode with a linear actuator. The double-arm gripper with two actuatable arms was able to pick up objects of sizes up to 2 mm and yet generate lower compressive forces as compared to elastomer-coated and non-coated rigid grippers. The feasibility of having other designs, such as single-arm or hook gripper, was also demonstrated, which further highlighted the customizability of the soft gripper device, and it's potential to be used in delicate surgical manipulation to reduce the risk of tissue grip damage.

  5. Effects of X radiation on the retina of the albino rabbit as viewed with the scanning electron microscope

    SciTech Connect

    Newton, J.C.; Barsa-Newton, M.C.; Wardly, J.

    1980-02-01

    The eyes of albino rabbits were exposed in vivo to 7000 rad of X radiation, and the retinas were examined with a scanning electron microscope 24 and 72 h after irradiation. The rods and cones of the retina were observed to show the most severe damage.

  6. Scleral Cross-linking Using Riboflavin and Ultraviolet-A Radiation for Prevention of Axial Myopia in a Rabbit Model.

    PubMed

    Dotan, Assaf; Kremer, Israel; Gal-Or, Orly; Livnat, Tami; Zigler, Arie; Bourla, Dan; Weinberger, Dov

    2016-04-03

    Myopic individuals, especially those with severe myopia, are at higher-than-normal risk of cataract, glaucoma, retinal detachment and chorioretinal abnormalities. In addition, pathological myopia is a common irreversible cause of visual impairment and blindness. Our study demonstrates the effect of scleral crosslinking using riboflavin and ultraviolet-A radiation on the development of axial myopia in a rabbit model. The axial length of the eyeball was measured by A-scan ultrasound in New Zealand white rabbits aged 13 days (male and female). The eye then underwent 360° conjunctival peritomy with scleral crosslinking, followed by tarsorrhaphy. Axial elongation was induced in 13 day-old New Zealand rabbits by suturing their right eye eyelids (tarsorrhaphy). The eyes were divided into quadrants, and every quadrant had two scleral irradiation zones, each with an area of 0.2 cm² and a radius of 4 mm. Crosslinking was performed by dropping 0.1% dextran-free riboflavin-5-phosphate onto the irradiation zones 20 sec before ultraviolet-A irradiation and every 20 sec during the 200 sec irradiation time. UVA radiation (370 nm) was applied perpendicular to the sclera at 57 mW/cm² (total UVA light dose, 57 J/cm²). Tarsorrhaphies were removed on day 55, followed by repeated axial length measurements. This study demonstrates that scleral crosslinking with riboflavin and ultraviolet-A radiation effectively prevents occlusion-induced axial elongation in a rabbit model.

  7. Smartphone monitoring of pneumatic tube system-induced sample hemolysis.

    PubMed

    Mullins, Garrett R; Harrison, James H; Bruns, David E

    2016-11-01

    Pneumatic tube systems (PTSs) are convenient methods of patient sample transport in medical centers, but excessive acceleration force and time/distance traveled in the PTS have been correlated with increased blood-sample hemolysis. We investigated the utility of smartphones for monitoring of PTS-related variables. Smartphones were sent through the PTS from several hospital locations. Each smartphone used 2 apps as data-loggers to record force of acceleration vs time. To relate the smartphone data to sample integrity, blood samples were collected from 5 volunteers, and hemolysis of the samples was analyzed after they were transported by hand or via 1 of 2 PTS routes. Increased sample hemolysis as measured by plasma lactate dehydrogenase (LD) was also related to the amount of transport in the PTS. The smartphones showed higher duration of forceful acceleration during transport through 1 of the 2 PTS routes, and the increased duration correlated with significant increases in hemolysis (H)-index and plasma LD. In addition, plasma LD showed a positive linear relationship with number of shock forces experienced during transport through the PTS. Smartphones can monitor PTS variables that cause sample hemolysis. This provides an accessible method for investigating specific PTS routes in medical centers. Copyright © 2016 Elsevier B.V. All rights reserved.

  8. Prediction and Reduction of Noise in Pneumatic Bleed Valves

    NASA Astrophysics Data System (ADS)

    Taghavi Nezhad, Shervin

    This study investigates numerically the fluid mechanics and acoustics of pneumatic bleed valves used in turbofan engines. The goal is to characterized the fundamental processes of noise generation and devise strategies for noise reduction. Three different methods are employed for both analysis and redesign of the bleed valve to reduce noise. The bleed valve noise problem is carefully divided into multiple smaller problems. For large separations and tonal noises, the unsteady Reynolds-Averaged Navier-Stokes (URANS) method is utilized. This method is also applied in the re-designing of the bleed valve geometry. For the bleed valve muffler, which is comprised of perforated plates and a honeycomb, a Reynolds-Averaged Navier-Stokes (RANS) method combined with a simplified acoustic analogy is used. The original muffler design is modified to improve noise attenuation. Finally, for sound scattering through perforated plates, a fully implicit linearized Euler solver is developed. The problem of sound interaction with perforated plates is studied from two perspectives. In the first study the effect of high--speed mean flow is considered and it is shown that at Strouhal numbers of around 0.2-0.25 there is an increase in transmitted incident sound. In the second part, the interaction of holes in two--dimensional perforated plates is investigated using three different configurations. The study demonstrates that the hole interaction has a significant impact on sound attenuation, especially at high frequencies.

  9. Controllable surface haptics via particle jamming and pneumatics.

    PubMed

    Stanley, Andrew A; Okamura, Allison M

    2015-01-01

    The combination of particle jamming and pneumatics allows the simultaneous control of shape and mechanical properties in a tactile display. A hollow silicone membrane is molded into an array of thin cells, each filled with coffee grounds such that adjusting the vacuum level in any individual cell rapidly switches it between flexible and rigid states. The array clamps over a pressure-regulated air chamber with internal mechanisms designed to pin the nodes between cells at any given height. Various sequences of cell vacuuming, node pinning, and chamber pressurization allow the surface to balloon into a variety of shapes. Experiments were performed to expand existing physical models of jamming at the inter-particle level to define the rheological characteristics of jammed systems from a macroscopic perspective, relevant to force-displacement interactions that would be experienced by human users. Force-displacement data show that a jammed cell in compression fits a Maxwell model and a cell deflected in the center while supported only at the edges fits a Zener model, each with stiffness and damping parameters that increase at higher levels of applied vacuum. This provides framework to tune and control the mechanical properties of a jamming haptic interface.

  10. Abdominal Palpation Haptic Device for Colonoscopy Simulation Using Pneumatic Control.

    PubMed

    Cheng, M; Marinovic, W; Watson, M; Ourselin, S; Passenger, J; De Visser, H; Salvado, O; Riek, S

    2012-01-01

    In this paper, we describe the development of a haptic device to be used in a simulator aiming to train the skills of gastroenterology assistants in abdominal palpation during colonoscopy, as well as to train team interaction skills for the colonoscopy team. To understand the haptic feedback forces to be simulated by the haptic device, we conducted an experiment with five participants of varying BMI. The applied forces and displacements were measured and hysteresis modeling was used to characterize the experimental data. These models were used to determine the haptic feedback forces required to simulate a BMI case in response to the real-time user interactions. The pneumatic haptic device consisted of a sphygmomanometer bladder as the haptic interface and a fuzzy controller to regulate the bladder pressure. The haptic device showed good steady state and dynamic response was adequate for simulating haptic interactions. Tracking accuracy averaged 94.2 percent within 300 ms of the reference input while the user was actively applying abdominal palpation and minor repositioning.

  11. Characterizating Multi-layered Coastal Aquifer using Pneumatic Slug Tests

    NASA Astrophysics Data System (ADS)

    Malama, B.; Abere, M.; Mikenna, M.

    2016-12-01

    Results of pneumatic slug tests conducted in a monitoring wells of a shallow aquifer on the California Central Coast are presented. The aquifer is in the Los Osos groundwater basin on the California Central Coast, a semi-closed near-triangular groundwater basin bounded to the north and south by impermeable igneousbed rock and to the west by the Pacific Ocean. The groundwater basin is a multi-layered system comprising a perched, near-surface semi-confined, and a deep confined aquifer. The unincorporated community of Los Osos is wholly dependent on the groundwater basin that is threatened with seawater intrusion and nitratecontamination. The slug tests reported here were performed in the perched and semi-confined aquifers as part of a seawater intrusion characterization study. The semi-confined and confined aquifers show evidence of seawater intrusion with upconing in some deep aquifer municipal wells. The upconing has beeninterpreted by previous studies as evidence of preferential flow through a high permeability channel. The objective of the work was to test this hypothesis by mapping the horizontal and vertical spatial variability of hydraulic parameters across the basin and establish the extent of the high permeability unit.Here only preliminary results of slug tests conducted across the basin for vertically averaged hydraulic parameters are reported. The results provide an indication of the horizontal variability of hydraulic parameters. An additional study will be performed to characterize the vertical variability to investigate the probableexistsence of a high permeability channel.

  12. Observations of ''granular jump'' in the pneumatic conveying system

    SciTech Connect

    Jaworski, Artur J.; Dyakowski, Tomasz

    2007-08-15

    This paper presents a preliminary study of a previously unreported phenomenon of the ''gas driven granular jump'', observed in the gas-solids flow within the pneumatic conveying system. From the phenomenological point of view, it resembles the already known processes such as hydraulic jumps in shallow water or granular jumps in granular flows in chutes or avalanches (although it seems most appropriate to explain it by analogy to a propagating granular bore). Clearly, unlike in classical phenomena of this type, the flow itself is driven by the aerodynamic forces related to the gas flow and the behaviour of the front of the ''jump'' is modified significantly by their presence. A series of high-speed camera visualisations are presented, which focus on this unusual behaviour of the flow on the border-line between cluster and stratified flow regimes in a horizontal pipe. Some similarities are drawn between the observed phenomenon and the broader class of problems exhibiting transition between super- and sub-critical flows. The fluid dynamical aspects and possible mechanisms behind the new phenomenon are discussed and the results obtained are compared quantitatively with simple theoretical models. (author)

  13. Portable pneumatic biventricular driver for the Thoratec ventricular assist device.

    PubMed

    Farrar, D J; Buck, K E; Coulter, J H; Kupa, E J

    1997-01-01

    As patients with left ventricular (LVAD) and biventricular assist devices are supported for increasingly long durations while awaiting heart transplantation or cardiac recovery, there is a need to facilitate greater patient mobility and ambulation. To meet these needs, the authors have developed the Thoratec TLC-II Portable VAD Driver, which is a small brief-case sized (33 x 34 x 13 cm) pneumatic unit for Thoratec's paracorporeal and implantable VADs. The TLC-II consists of an electric motor driven air compressor for supplying both positive and negative air pressure, solenoid valves for switching between LVAD/RVAD filling and ejection, and microcontroller based electronics and firmware. Four power sources are provided: external power, two rechargeable lithium-ion battery packs, and an emergency battery that drives an independent electronic back-up system. The 8 kg TLC-II can be carried by hand, with a shoulder strap, or pushed on a wheeled mobility cart. Trend information stored in the TLC-II can be accessed by an external system computer with a color touchscreen mounted on a docking station, which also houses the battery charger. Control configurations (univentricular/biventricular operation, beat rates, etc.) are entered on the touchscreen and programmed into the TLC-II. In vitro testing demonstrates the ability to pump VAD outputs up to 7 L/min. By providing improved patient mobility, this small driver will enhance rehabilitation and improve the quality of life of VAD patients.

  14. MRI-Compatible Pneumatic Robot for Transperineal Prostate Needle Placement

    PubMed Central

    Fischer, Gregory S.; Iordachita, Iulian; Csoma, Csaba; Tokuda, Junichi; DiMaio, Simon P.; Tempany, Clare M.; Hata, Nobuhiko; Fichtinger, Gabor

    2010-01-01

    Magnetic resonance imaging (MRI) can provide high-quality 3-D visualization of prostate and surrounding tissue, thus granting potential to be a superior medical imaging modality for guiding and monitoring prostatic interventions. However, the benefits cannot be readily harnessed for interventional procedures due to difficulties that surround the use of high-field (1.5T or greater) MRI. The inability to use conventional mechatronics and the confined physical space makes it extremely challenging to access the patient. We have designed a robotic assistant system that overcomes these difficulties and promises safe and reliable intraprostatic needle placement inside closed high-field MRI scanners. MRI compatibility of the robot has been evaluated under 3T MRI using standard prostate imaging sequences and average SNR loss is limited to 5%. Needle alignment accuracy of the robot under servo pneumatic control is better than 0.94 mm rms per axis. The complete system workflow has been evaluated in phantom studies with accurate visualization and targeting of five out of five 1 cm targets. The paper explains the robot mechanism and controller design, the system integration, and presents results of preliminary evaluation of the system. PMID:21057608

  15. An electromagnetic microvalve for pneumatic control of microfluidic systems.

    PubMed

    Liu, Xuling; Li, Songjing

    2014-10-01

    An electromagnetic microvalve for pneumatic control of microfluidic devices has been designed, fabricated, and tested. The microvalve is composed of two parts: a miniature electromagnetic actuator and a valve body. The electromagnetic actuator consists mainly of a thin polydimethylsiloxane (PDMS)-based elastomer, which acts as the valve diaphragm. The diaphragm, used as a solid hydraulic medium, converts the large contact area of a valve core into a small contact area of valve head while maintaining a large stroking force. This microvalve remains closed because of a compressed mechanical spring force generated by the actuator. On the other hand, when a voltage is applied, the valve core moves up, relaxing the thin PDMS membrane, opening the microvalve. The fast open response (~17 ms) of the valve was achieved with a leak rate as low as 0.026 sccm at 200 KPa (N2) pressure. We tested the pertinent dynamic parameters such as flow rate in on/off mode, flow rate of duty cycles, and actuated frequencies in pulse width modulation (PWM) mode. Our method provides a simple, cheap, and small microvalve that avoids the bulky and expensive external pressure control solenoid manifold. This allows it to be easily integrated into portable and disposable devices.

  16. Pneumatic impression: Improving dental arch impression with an inflatable balloon.

    PubMed

    Gupta, Lokendra

    2016-01-01

    The purpose of this impression technique is to overcome the problem associated with restricted mouth opening in association with high arched palate by employing pneumatic impression technique using latex balloon. A stock tray was modified with auto polymerizing acrylic resin. On the modified tray, a latex balloon was attached with aid of cyanoacrylate. The outlet of the balloon was then connected to a clinical sphygmomanometer bulb with the rubber pipe for air passage which would aid in inflating the balloon. The prepared tray assembly was then equipped for recording the impression. An adequate amount of addition polysiloxane impression material, sufficient to cover the entire area of the balloon was loaded onto the tray. The balloon was then inflated with the help of a sphygmomanometer bulb which transferred the air only in one direction. On completion of setting time of the impression material, the air pressure was relieved by deflating of balloon which helped in the easy removal of the impression. The impression was subsequently removed from the oral cavity and disinfected. This novel technique was helpful for recording impression in patients presenting with restricted mouth opening and high arched palate.

  17. Effectiveness of Thermal-Pneumatic Airfoil-Ice-Protection System

    NASA Technical Reports Server (NTRS)

    Gowan, William H., Jr.; Mulholland, Donald R.

    1951-01-01

    Icing and drag investigations were conducted in the NACA Lewis icing research tunnel employing a combination thermal-pneumatic de-icer mounted on a 42-inch-chord NACA 0018 airfoil. The de-icer consisted of a 3-inch-wide electrically heated strip symmetrically located about the leading edge with inflatable tubes on the upper and lower airfoil surfaces aft of the heated area. The entire de-icer extended to approximately 25 percent of chord. A maximum power density of 9.25 watts per square inch was required for marginal ice protection on the airfoil leading edge at an air temperature of 00 F and an airspeed of 300 miles per hour. Drag measurements indicated, that without icing, the de-icer installation increased the section drag to approximately 140 percent of that of the bare airfoil; with the tubes inflated, this value increased to a maximum of approximately 620 percent. A 2-minute tube-inflation cycle prevented excessive ice formation on the inflatable area although small scattered residual Ice formations remained after inflation and were removed intermittently during later cycles. Effects of the time lag of heater temperatures after initial application of power and the insulating effect of ice formations on heater temperatures were also determined.

  18. Variable recruitment in bundles of miniature pneumatic artificial muscles.

    PubMed

    DeLaHunt, Sylvie A; Pillsbury, Thomas E; Wereley, Norman M

    2016-09-13

    The natural compliance and force generation properties of pneumatic artificial muscles (PAMs) allow them to operate like human muscles in anthropomorphic robotic manipulators. Traditionally, manipulators use a single PAM or multiple PAMs actuated in unison in place of a human muscle. However, these standard manipulators can experience significant efficiency losses when operated outside their target performance ranges at low actuation pressures. This study considers the application of a variable recruitment control strategy to a parallel bundle of miniature PAMs as an attempt to mimic the selective recruitment of motor units in a human muscle. Bundles of miniature PAMs are experimentally characterized, their actuation behavior is modeled, and the efficiency gains and losses associated with the application of a variable recruitment control strategy are assessed. This bio-inspired control strategy allows muscle bundles to operate the fewest miniature PAMs necessary to achieve a desired performance objective, improving the muscle bundle's operating efficiency over larger ranges of force generation and displacement. The study also highlights the need for improved PAM fabrication techniques to facilitate the production of identical miniature PAMs for inclusion in muscle bundles.

  19. Testing techniques for determining static mechanical properties of Pneumatic tires

    NASA Technical Reports Server (NTRS)

    Dodge, R. N.; Larson, R. B.; Clark, S. K.; Nybakken, G. H.

    1974-01-01

    Fore-aft, lateral, and vertical spring rates of model and full-scale pneumatic tires were evaluated by testing techniques generally employed by industry and various testing groups. The purpose of this experimental program was to investigate what effects the different testing techniques have on the measured values of these important static tire mechanical properties. The testing techniques included both incremental and continuous loadings applied at various rates over half, full, and repeated cycles. Of the three properties evaluated, the fore-aft stiffness was demonstrated to be the most affected by the different testing techniques used to obtain it. Appreciable differences in the fore-aft spring rates occurred using both the increment- and continuous-loading techniques; however, the most significant effect was attributed to variations in the size of the fore-aft force loop. The dependence of lateral stiffness values on testing techniques followed the same trends as that for fore-aft stiffness, except to a lesser degree. Vertical stiffness values were found to be nearly independent of testing procedures if the nonlinear portion of the vertical force-deflection curves is avoided.

  20. [Endoscopic sclerosis with pneumatic distension for pyriform sinus fistula treatment].

    PubMed

    Sanchís Blanco, G; Gutiérrez San Román, C; Bordallo Vázquez, M; Cortés Sáez, J; Barrios Fontoba, J E; Lluna González, J; Esteban Ricós, M J; Vila Carbó, J J

    2014-01-01

    Classic treatment for pyriform sinus fistula (PSF) has been surgical excision; however, less invasive therapeutic alternatives whose aim is the obliteration of the sinus have been described subsequently. The authors present a technical modification of endoscopic sclerosis with diathermy (ESD): continuous infusion of air flow through the flexible endoscope was used to distend the pyriform sinus and facilitate recognition of the fistula opening. The sinus obliteration was performed with a wire guide and diathermy. In the last 15 years, 9 patients were diagnosed of suffering from PSF in our institution. Initial treatment was antibiotics therapy associated in some cases to cervical abscess drainage. Fistulectomy was performed in 4 cases and ESD in 4. The ninth patient received both treatments, performing electrocauterization after a surgical recurrence. Three of the patients who underwent surgery relapsed; none treated by ESD did, or had any complications. In our experience, endoscopic sclerosis with pneumatic distension is a simple technique, reproducible, not invasive and very effective; hence we consider it might become a first line therapy for PSF.