Science.gov

Sample records for pneumatic irradiation rabbit

  1. Nerve function and structure beneath and distal to a pneumatic tourniquet applied to rabbit hindlimbs.

    PubMed

    Pedowitz, R A; Nordborg, C; Rosenqvist, A L; Rydevik, B L

    1991-01-01

    Neurophysiologic and neuropathologic changes were studied in rabbit hindlimbs after 2 hours of pneumatic tourniquet application with either 350 mmHg (n = 18) or 1,000 mmHg (n = 6) cuff inflation pressure. The toe spread reflex was decreased in 66% and absent in 33% of limbs 2 days after 350 mmHg compression, and was absent in all limbs after 1,000 mmHg compression. Compound motor action potential amplitudes (CMAPs), recorded from the abductor hallucis muscle, were significantly decreased with sciatic nerve stimulation 1 hour after 350 mmHg compression. CMAPs returned to baseline values one and two days later, however nerve conduction velocity (NCV) was still significantly decreased in the compressed sciatic nerves of these groups. In contrast, complete nerve conduction block, localized beneath the cuff's distal border, was observed two days after 1,000 mmHg compression, and NCV was still significantly decreased distal to the tourniquet zone. Using light and electron microscopy, scattered axonal degeneration, mild myelin damage, and normal nodes of Ranvier were observed two days after 350 mmHg tourniquet compression. Severe fiber damage and nodal obliteration were noted after 1,000 mmHg tourniquet compression. Although nodal invagination is probably not a significant pathogenic mechanism at clinically relevant tourniquet pressures and durations, functional abnormalities were induced by 2 hour, 350 mmHg tourniquet compression. Such changes probably correlate with clinical electromyographic abnormalities and delayed post-operative recovery following 'routine' extremity surgery using pneumatic tourniquets.

  2. Skeletal muscle injury induced by a pneumatic tourniquet: an enzyme- and immunohistochemical study in rabbits.

    PubMed

    Pedowitz, R A; Fridén, J; Thornell, L E

    1992-03-01

    The pathophysiology of skeletal muscle injury induced by compression beneath pneumatic tourniquets is poorly understood. Tourniquet hemostasis was induced in rabbit hindlimbs for 2 hr with a cuff inflation pressure of either 125 mm Hg (n = 5) or 350 mm Hg (n = 5). Skeletal muscle biopsies, taken 2 days later from tissue beneath and distal to the tourniquet, were frozen and analyzed using enzyme- and immunohistochemical techniques. In the 350 mm Hg tourniquet group, four of 10 thigh muscle samples demonstrated significant regional necrosis (mean 37.3% of the total cross-sectional area). Regional necrosis was not observed in thigh muscles of the 125 mm Hg tourniquet group or in any of the ischemic leg muscles. A topographic pattern of necrosis consistent with the arterial distribution of skeletal muscle suggested pathogenic events during the reperfusion period, such as granulocyte-mediated superoxide radical formation. Extremely large and rounded fibers (histochemically identified as Type IIB fibers) were observed in compressed thigh muscles, indicating differential fiber sensitivity to tourniquet compression and ischemia. The present study demonstrated significant skeletal muscle necrosis after a 2 hr tourniquet applied at a clinically relevant cuff inflation pressure. Recent studies of systemic changes associated with limb "ischemia" should be reassessed in consideration of the confounding effects of tissue compression induced beneath pneumatic tourniquets.

  3. Superoxide dismutase activity in radioresistant tissues of irradiated rabbits.

    PubMed

    Stoklasová, A; Kovárová, H; Ledvina, M

    1992-01-01

    The activities of Cu, Zn-containing superoxide dismutase were studied in radioresistant tissues (liver, brain, erythrocytes) of whole-body irradiated rabbits with 6.0 Gy and 24.0 Gy with local shielding. No significant changes were observed after irradiation with 6.0 Gy. Both the changes in Cu, Zn-SOD activity and the protein concentrations were more pronounced after exposure to 24.0 Gy with local shielding of the head and abdominal region. The dose on the shielded regions was about 6.0 Gy. Local shielding of rabbits irradiated with a lethal dose 24.0 Gy influenced positively the survival of animals. However, the decrease in SOD activity on 60th day after irradiation seems to be unfavourable for further survival of rabbits, if we accept that SOD content in tissue is maintained at a rather constant level.

  4. Late degeneration in rabbit tissues after irradiation by heavy ions

    NASA Technical Reports Server (NTRS)

    Lett, J. T.; Cox, A. B.; Keng, P. C.; Lee, A. C.; Su, C. M.; Bergtold, D. S.

    1980-01-01

    Results are presented for investigations of the late effects of heavy-ion irradiation on rabbit tissues which were undertaken to assess the hazards associated with the long-term exposure of humans to heavy ions in space during such activities as the construction of solar power stations or voyages to Mars. White rabbits approximately six weeks old were exposed to various doses of collimated beams of 400-MeV/n Ne ions, 570 MeV/n Ar ions and Co-60 gamma rays directed through both eyes, and the responses of the various tissues (hair follicles, skin, cornea, lens, retina, Harderian glands, bone and forebrain) were examined. Proliferating tissues are found to exhibit high damage levels in the early and late periods following irradiation, while terminally differentiating tissues repond to radiation most intensely in the late period, years after irradiation, with no intermediate recovery. The results obtained from rabbits are used to predict the occurrence of late tissue degeneration in the central nervous system, terminally differentiating systems and stem cells of humans one or more decades following exposure to radiation levels anticipated during long-duration space flights. The studies also indicate that tissues may be prematurely aged in the sense that tissue life spans may be shortened without the development of malignancies.

  5. Effects of pre- and postoperative irradiation on the healing of bone grafts in the rabbit

    SciTech Connect

    Morales, M.J.; Marx, R.E.; Gottlieb, C.F.

    1987-01-01

    Healing of cellular bone grafts irradiated at various times in the postsurgical course was compared to the healing characteristics of bone grafts placed into already irradiated tissue and to controls of irradiated host mandible in a rabbit model. Physical graft consolidation was assessed by load stress characteristics and serial histologic examination. Results indicated that grafts placed into already irradiated tissues failed to form bone in both phases of expected regeneration resulting in structurally weakened and histologically deficient ossicles. Bone grafts irradiated after placement were tolerant of irradiation. Bone grafts irradiated after four weeks were found to be less affected by irradiation than those irradiated within the first four weeks, forming an ossicle structurally and histologically superior to that of bone ossicles developed from grafts placed into irradiated tissues.

  6. Disposable rabbit

    DOEpatents

    Lewis, Leroy C.; Trammell, David R.

    1986-01-01

    A disposable rabbit for transferring radioactive samples in a pneumatic transfer system comprises aerated plastic shaped in such a manner as to hold a radioactive sample and aerated such that dissolution of the rabbit in a solvent followed by evaporation of the solid yields solid waste material having a volume significantly smaller than the original volume of the rabbit.

  7. Disposal rabbit

    DOEpatents

    Lewis, L.C.; Trammell, D.R.

    1983-10-12

    A disposable rabbit for transferring radioactive samples in a pneumatic transfer system comprises aerated plastic shaped in such a manner as to hold a radioactive sample and aerated such that dissolution of the rabbit in a solvent followed by evaporation of the solid yields solid waste material having a volume significantly smaller than the original volume of the rabbit.

  8. Apraclonidine effects on ocular responses to YAG laser irradiation to the rabbit iris

    SciTech Connect

    Sugiyama, K.; Kitazawa, Y.; Kawai, K. )

    1990-04-01

    Apraclonidine (p-aminoclonidine) ophthalmic solution effectively reduces the rise in intraocular pressure (IOP) following anterior segment laser surgery. We tested the effect of topical 0.5% apraclonidine on intraocular pressure and on protein and prostaglandin (PG) E2 concentrations in aqueous humor following Q-switched Nd:YAG laser irradiation to the iris of albino rabbits, at an energy level of 2 to 200 mJ. IOP was measured prior to and for 24 hr after irradiation. Aqueous humor was withdrawn before and 1 hr after laser irradiation for determining protein (Lowry method) and PGE2 (radioimmunoassay). Four to seven rabbits were used for each experiment. The increase in IOP and protein concentration following laser irradiation was demonstrated to be dependent on the amount of laser energy. Apraclonidine completely abolished the IOP rise, and significantly reduced the elevation of protein content. Apraclonidine failed to affect the increase in PGE2.

  9. Gamma-Irradiated Sterile Cornea for Use in Corneal Transplants in a Rabbit Model

    PubMed Central

    Yoshida, Junko; Heflin, Thomas; Zambrano, Andrea; Pan, Qing; Meng, Huan; Wang, Jiangxia; Stark, Walter J.; Daoud, Yassine J.

    2015-01-01

    Purpose: Gamma irradiated corneas in which the donor keratocytes and endothelial cells are eliminated are effective as corneal lamellar and glaucoma patch grafts. In addition, gamma irradiation causes collagen cross inking, which stiffens collagen fibrils. This study evaluated gamma irradiated corneas for use in corneal transplantations in a rabbit model comparing graft clarity, corneal neovascularization, and edema. Methods: Penetrating keratoplasty was performed on rabbits using four types of corneal grafts: Fresh cornea with endothelium, gamma irradiated cornea, cryopreserved cornea, and fresh cornea without endothelium. Slit lamp examination was performed at postoperative week (POW) one, two, and four. Corneal clarity, edema, and vascularization were graded. Confocal microscopy and histopathological evaluation were performed. A P < 0.05 was statistically significant. Results: For all postoperative examinations, the corneal clarity and edema were statistically significantly better in eyes that received fresh cornea with endothelium compared to the other three groups (P < 0.05). At POW 1, gamma irradiated cornea scored better than the cryopreserved and fresh cornea without endothelium groups in clarity (0.9 vs. 1.5 and 2.6, respectively), and edema (0.6 vs. 0.8 and 2.0, respectively). The gamma irradiated corneas, cryopreserved corneas and the fresh corneas without endothelium, developed haze and edema after POW 2. Gamma irradiated cornea remained statistically significantly clearer than cryopreserved and fresh cornea without endothelium during the observation period (P < 0.05). Histopathology indicated an absence of keratocytes in gamma irradiated cornea. Conclusion: Gamma irradiated corneas remained clearer and thinner than the cryopreserved cornea and fresh cornea without endothelium. However, this outcome is transient. Gamma irradiated corneas are useful for lamellar and patch grafts, but cannot be used for penetrating keratoplasty. PMID:26180475

  10. [Rabbit facial nerve damager after Nd: YAG laser irradiation: an experimental study

    PubMed

    Yu, Y C; Zhang, Z Y; Zhou, G Y; Zhu, H G

    1999-12-01

    OBJECTIVE:To investigate the change effects of rabbit facial nerve after Nd:YAG laser irradiation.METHODS: According to therapeutic laser energy density,the facial nerves of 28 rabbits were irradiated by Nd:YAG laser with 5 different laser dosages.RESULTS: The facial nerves were functionally intact with mild degeneration histologically at three weeks postoperatively,when the energy density of Nd: YAG laserlaser lower than 70J/cm(2).In the group with energy density of 140J/cm(2),facial nerve density functionally impaired with moderate degeneration which rehabilitated within six weeks. While the laser power increaseed to more than 240J/cm(2),irreversible nerve damages happened.CONCLUSION: laser thermal effect is the main cause of nerve damage,there is a positive correlation between laser dosage and nerve impairment.

  11. External beam irradiation in angioplasted arteries of hypercholesterolemic rabbits The dose and time effect

    SciTech Connect

    Kalef-Ezra, J.; Michalis, L.K.; Malamou-Mitsi, V.; Tsekeris, P.; Katsouras, C.; Boziari, A.; Toumpoulis, I.; Bozios, G.; Charchanti, A.; Sideris, D.A

    2002-03-01

    Purpose: To study the dose and time effect of external beam irradiation on the morphometry of both angioplasted and nonangioplasted arteries in a hypercholesterolemic rabbit model. Methods and materials: Eight groups of rabbit femoral arteries were studied: arteries (a) with no intervention, (b) irradiated with a 12-Gy 6 MV X-ray dose, (c) with a 18-Gy, (d) treated with balloon angioplasty, (e) dosed with 12-Gy half an hour post-angioplasty, (f) dosed with 18-Gy half an hour post-angioplasty, (g) dosed with 12-Gy 48 h post angioplasty, (g) dosed with 18-Gy 48 h post angioplasty. Results: External irradiation at either 12 or 18 Gy was not found to change vessel morphometry in noninjured arteries. The 12-Gy dose given soon after angioplasty further increased percentage stenosis (63% on the average), despite the preservation of the lumen cross-sectional area. Positive remodeling was not observed in arteries given 18-Gy half an hour post angioplasty to counterbalance the increased neointimal formation. Therefore, this treatment resulted in a drastic reduction in lumen area and in enhancement of percentage stenosis (84% on the average). On the contrary, the delayed irradiation of the angioplasted arteries at either 12 or 18 Gy was not found to influence any of the studied morphometric parameters 5 weeks after angioplasty. Conclusions: Uniform external beam irradiation up to 18 Gy was well tolerated by intact femoral arteries. Prompt 12- or 18-Gy irradiations accentuated percentage stenosis. However the lumen cross-sectional area was preserved only at the lower dose point. Delayed irradiation at any dose did not influence the restenosis process.

  12. Kinetics of (/sup 14/C-5) 8-methoxypsoralen uptake by UVA irradiated and non-irradiated rabbit eye tissues

    SciTech Connect

    Malinin, G.I.; Glew, W.B.; Roberts, W.P.; Nigra, T.P.

    1981-05-01

    Total 8-methoxypsoralen (8-MOP) in intact and UVA irradiated rabbit eye tissues and its unaltered fraction in aqueous and eye lenses were determined over the 24 hours after i.v. injection of (/sup 14/C-5) and carrier 8-MOP at the concentration of 50 microCi and 5 mg/kg. No 8-MOP was detected at the end of 24 hours in intact and irradiated aqueous, vitreous and retina in contrast to one hour when the respective levels were congruent to 220, greater than 0 and congruent to 160 ng/g. Eye-plasma drug concentration ratios were less than 0.5 initially, but increased thereafter. While the average lens 8-MOP levels of congruent to 140 ng/g remained unchanged for 24 hours, no unaltered drug was detected beyond eight hours. Measurable amounts of label at the end of 24 hours also persisted in the cornea, iris, sclera and conjunctiva.

  13. [Thermocompensatory reactions of rabbits in response to microwave irradiation at different environmental temperatures].

    PubMed

    Kolganova, O I; Zhavronkov, L P; Petin, V G; Drozd, A I; Glushakova, V S; Panferova, T A

    2001-01-01

    Thermogenic effectiveness of electromagnetic irradiation (EMI) of UHF range (7 GHz) in the dependence on intensity (10-100 mW/cm2) and environmental temperature was studied in experiments with rabbits. Synergistic interaction of EMI and high ambient temperature was established. The existence of optimal EMI and high ambient temperature was established. The existence of optimal EMI intensity at which the synergy was maximal was shown. It is concluded that this interaction should be taken into account for hygienic standardization of nonionizing EMI.

  14. Effect of low-power helium-neon laser irradiation on 13-week immobilized articular cartilage of rabbits.

    PubMed

    Bayat, Mohammad; Ansari, Anayatallah; Hekmat, Hossien

    2004-09-01

    Influence of low-power (632.8 nm, Helium-Neon, 13 J/cm2, three times a week) laser on 13-week immobilized articular cartilage was examined with rabbits knee model. Number of chondrocytes and depth of articular cartilage of experimental group were significantly higher than those of sham irradiated group. Surface morphology of sham-irradiated group had rough prominences, fibrillation and lacunae but surface morphology of experimental group had more similarities to control group than to sham irradiated group. There were marked differences between ultrastructure features of control group and experimental group in comparison with sham irradiated group. Low-power Helium-Neon laser irradiation on 13-week immobilized knee joints of rabbits neutrilized adverse effects of immobilization on articular cartilage.

  15. Effect of helium-neon and infrared laser irradiation on wound healing in rabbits

    SciTech Connect

    Braverman, B.; McCarthy, R.J.; Ivankovich, A.D.; Forde, D.E.; Overfield, M.; Bapna, M.S.

    1989-01-01

    We examined the biostimulating effects of helium-neon laser radiation (HeNe; 632.8 nm), pulsed infrared laser radiation (IR; 904 nm), and the two combined on skin wound healing in New Zealand white rabbits. Seventy-two rabbits received either (1) no exposure, (2) 1.65 J/cm2 HeNe, (3) 8.25 J/cm2 pulsed IR, or (4) both HeNe and IR together to one of two dorsal full-thickness skin wounds, daily, for 21 days. Wound areas were measured photographically at periodic intervals. Tissue samples were analyzed for tensile strength, and histology was done to measure epidermal thickness and cross-sectional collagen area. Significant differences were found in the tensile strength of all laser-treated groups (both the irradiated and nonirradiated lesion) compared to group 1. No differences were found in the rate of wound healing or collagen area. Epidermal growth was greater in the HeNe-lased area compared to unexposed tissue, but the difference was not significant. Thus, laser irradiation at 632.8 nm and 904 nm alone or in combination increased tensile strength during wound healing and may have released tissue factors into the systemic circulation that increased tensile strength on the opposite side as well.

  16. Craniocervical Pneumatization

    PubMed Central

    Quigley, Alan James; Shannon, Helen

    2013-01-01

    Craniocervical bony pneumatization is a rare finding, with limited numbers of cases reported in the literature. It is thought to be linked to Eustachian tube dysfunction and a ball valve mechanism, and has a link with recurrent Valsalva maneuvers. We report a case of pneumatization of the occiput, atlas (C1) and axis (C2) in a patient with extensive ENT (Ear, Nose and Throat) surgical history who presented following a fall. Plain film, CT and MRI images are presented. PMID:24421950

  17. The irradiation of rabbit sperm cells with He-Ne laser prevents their in vitro liquid storage dependent damage.

    PubMed

    Iaffaldano, Nicolaia; Rosato, Maria Pina; Paventi, Gianluca; Pizzuto, Roberto; Gambacorta, Mario; Manchisi, Angelo; Passarella, Salvatore

    2010-05-01

    The aim of the study was to investigate the effects of different energy doses of helium-neon (He-Ne) laser irradiation on both mitochondrial bioenergetics functions and functional quality of rabbit spermatozoa during 48 h of in vitro liquid storage at 15 degrees C. 11 rabbit semen pools were each divided into four aliquots: three of them were irradiated with He-Ne laser with different energy doses (3.96, 6.12 and 9.00 J/cm(2)) being the last control kept under the same experimental conditions without irradiation. Sperm motility, viability and acrosome integrity were monitored together with cytochrome c oxidase (COX) activity and the cell energy charge (EC) at 0, 24 and 48 h of storage. Irradiated samples stored for 24 and 48 h better maintained motility (P < 0.01), acrosome integrity (P < 0.01) and viability (P < 0.05) with respect to the control, particularly with the energy dose of 6.12 J/cm(2) that showed the most intense biostimulative effect. COX activity and EC were immediately increased by irradiation particularly in the treatments 6.12 and 9.00 J/cm(2) (P < 0.05), that maintained their levels higher with respect to the control after 48 h of storage (P < 0.01). COX activity of rabbit sperm cells was positively correlated with EC (P < 0.05), viability (P < 0.01) and acrosome integrity (P < 0.05) parameters. These results indicate that the effects of He-Ne laser irradiation on sperm cells are mediated through the stimulation of the sperm mitochondrial respiratory chain and that this effect plays a significant role in the augmentation of the rabbit sperm cells' capability to survive during liquid storage conditions.

  18. A Rabbit Irradiation Platform for Outcome Assessment of Lung Stereotactic Radiosurgery

    SciTech Connect

    Cai Jing; Mata, Jaime F.; Orton, Matthew D.; Hagspiel, Klaus D.; Mugler, John P.; Larner, James M.; Sheng Ke; Read, Paul W.

    2009-04-01

    Purpose: To evaluate a helical tomotherapy-based rodent radiosurgery platform that reproduces human image-guided radiosurgery treatment to study radiobiologic effects of stereotactic radiosurgery on lung tissues using functional magnetic resonance imaging (MRI). Methods and Materials: Hypofractionated radisourgery (20 Gy x 3) was delivered to the right lung of three New Zealand rabbits using Helical TomoTherapy with MVCT image guidance. Contrast-enhanced MR perfusion, hyperpolarized helium-3 MR ventilation, and CT were obtained before radiation and monthly for 4 months after radiation. All MRI was performed on a 1.5-T whole-body scanner with broad-band capabilities. Results: Precise dose delivery to 1.6 cc of the lower right lung was achieved without additional immobilization. No deficits were detected at baseline with respect to perfusion and ventilation. Lung perfusion deficits in the irradiated lung regions began at 2 months after radiation and worsened with time. No ventilation deficits were observed after radiation. Decrease in lung CT density in irradiated regions was observed after radiation, but the changes were less significant than those in perfusion MRI. Conclusions: We demonstrated that highly conformal radiation can be reproducibly delivered to a small volume of rodent lung on a widely available clinical unit. The radiation-induced lung injury can be detected as early as 2 months after radiation with perfusion MRI. The primary pattern of injury agrees with previously reported endothelial damage to radiosurgical radiation doses. This experimental design provides a cost-effective methodology for producing radiosurgical injuries in rodents that reproduces current human treatments for studying radiation injury and agents that might affect it.

  19. Investigation of carbohydrate and protein metabolism in the digestive organs of the rabbit under the combined influence of vibration, acceleration and irradiation

    NASA Technical Reports Server (NTRS)

    Yuy, R. I.

    1975-01-01

    During spaceflight, the organism is subjected to the influence of various extremal factors such as acceleration, vibration, irradiation, etc. The study of the influence of these factors on metabolism, especially carbohydrate and protein metabolism, in young rabbits is of great significance in simulation experiments. Dynamic factors and irradiation, depending on dose and duration, lead to reduced RNA and protein metabolism.

  20. Differential analysis of D-{beta}-Asp-containing proteins found in normal and infrared irradiated rabbit lens

    SciTech Connect

    Takata, Takumi; Shimo-Oka, Tadashi; Kojima, Masami; Miki, Kunio; Fujii, Noriko . E-mail: nfujii@HL.rri.kyoto-u.ac.jp

    2006-05-26

    Although proteins are generally composed of L-{alpha}-amino acids, D-{beta}-aspartic acid (Asp)-containing proteins have been reported in various elderly tissues. Our previous study detected several D-{beta}-Asp-containing proteins in a rabbit lens derived from epithelial cell line by Western blot analysis of a 2D-gel using a polyclonal antibody that is highly specific for D-{beta}-Asp-containing proteins. The identity of each spot was subsequently determined by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry and the Ms-Fit online database searching algorithm. In this study, we discovered novel D-{beta}-Asp-containing proteins from rabbit lens. The results indicate that {beta}-crystallin A3, {beta}-crystallin A4, {beta}-crystallin B1, {beta}-crystallin B2, {beta}-crystallin B3, {gamma}-crystallin C, {gamma}-crystallin D, and {lambda}-crystallin in rabbit lens contain D-{beta}-Asp residues. Furthermore, the occurrence of D-{beta}-Asp residues increases with infrared ray (IR) irradiation. Additionally, some D-{beta}-Asp-containing proteins only appear after IR irradiation. One such protein is the {alpha}-enolase, which shows homology to {tau}-crystallin.

  1. Axon reflex in ocular injury: sensory mediation of the response of the rabbit eye to laser irradiation of the iris.

    PubMed

    Butler, J M; Unger, W G; Cole, D F

    1980-10-01

    Laser irradiation of the rabbit iris produces an injury response consisting of prolonged miosis, uveal vasodilation and a transient rise of intraocular pressure (IOP) accompanied by a breakdown of the blood-aqueous barrier. This response has hitherto been attributed partly to prostaglandin (PG) mediation and partly to mediation by a non-cholinergic nervous pathway thought to be sensory in fuction. Responses of the rabbit eye to laser irritation were examined at specified intervals after diathermic coagulation of the epigasserian nerve tract. Both the intensity of the pupillary constriction and the increase in IOP were almost unaltered at 90 minutes but progressively decreased until at 4 days there was essentially no response to high energy laser irradiation in the denervated eye. It was evident that manifestation of the response is largely dependent upon the presence of intact and functional sensory nerves, and it is proposed that endogenous PGs exert some, if not all of their effects via sensory nerve endings. It is suggested that those terminals which are directly stimulated, whether by laser irradiation or by PGs formed during the injury, release some mediator to cause pupillary constriction. From thes terminals impulses pass orthodromically and antidromically by axon reflex to release further mediator from terminals in the region of the ciliary vessels or the major arterial circle. In this way the response is propagated and augmented.

  2. Effects of low-intensity laser irradiation on the apoptosis of rabbit vascular smooth muscle cells in culture

    NASA Astrophysics Data System (ADS)

    Li, S. D.; Chen, P.; Zhang, C. P.; Wen, J. X.; Liang, J.; Kang, H. X.; Gao, R. L.; Fu, X. B.

    2011-11-01

    Restenosis is a major complication after coronary intervention therapy. Excessive proliferation of vascular smooth muscle cells (VSMCs) and a decline in their apoptosis, which eventually leads to excessive neointimal thickening in coronary arteries, are the main causes of restenosis. Induction of the apoptosis of VSMCs and inhibition of excessive proliferation of VSMCs are therefore crucial for the prevention of restenosis, and low-intensity laser irradiation of coronary arteries may play a promising role in keeping this in balance. In this study, we used in vitro cultured rabbit VSMCs to investigate the effects of low-intensity laser irradiation at a wavelength of 532 nm on the apoptosis of VSMCs via morphological observation and molecular biology. The results showed that apoptotic bodies and obvious intranuclear apoptosis-positive particles formed within VSMCs 24 h after laser irradiation, suggesting that low-intensity laser irradiation at certain doses can inhibit the proliferation of VSMCs by promoting their apoptosis. This experiment provides evidences for further animal experiments and clinical trials on prevention and treatment of restenosis by intracoronary low-intensity laser irradiation at a wavelength of 532 nm.

  3. The effect of topical dexamethasone and preoperative beta irradiation on a model of glaucoma fistulizing surgery in the rabbit

    SciTech Connect

    Miller, M.H.; Grierson, I.; Unger, W.G.; Hitchings, R.A. )

    1990-01-01

    We studied the effect of topical dexamethasone (1%) and preoperative beta irradiation on a model of glaucoma fistulizing surgery in the rabbit. Intraocular pressure and gross facility of aqueous outflow following surgery were not influenced by either treatment, although blebs persisted longer in the irradiated eyes. Steroids reduced clinically observable inflammation as well as the number of inflammatory cells identifiable by microscopy. Fibroblast production temporarily slowed, and ultrastructural examination demonstrated lipid-filled vacuoles and dilated mitochondria in these eyes. Also, the scar was thinner at 24 days. Beta irradiation delayed wound healing and the scar was thinner in the early postoperative stages, but the light microscopic appearance of the scar was unaltered at 59 days. Inflammation was more pronounced initially, with abundant fibrin in the wound. Recovery of the conjunctival epithelium was delayed. The delay in fibroblast recruitment and wound contraction, the thinner scar tissue, and the increased survival of the bleb are all factors that suggest that beta irradiation may be a useful adjunct to glaucoma surgery.

  4. High resolution scanning electron microscopy of rabbit corneal endothelium to show effects of UV-visible irradiation in the presence of chlorpromazine

    SciTech Connect

    Lea, P.J.; Hollenberg, M.J.; Menon, I.A.; Temkin, R.J.; Persad, S.D.; Basu, P.K. )

    1989-01-01

    The ultrastructure of rabbit cornea endothelial cells was examined by scanning electron microscopy (SEM) in freeze-cleaved corneas using a Hitachi S-570 scanning electron microscope in the high resolution mode (HRSEM). In order to study phototoxic effects in vitro, rabbit corneas (experimental) were cultured as organ culture in the presence of 5 micrograms/ml chlorpromazine (CPZ) and irradiated. For comparison, control 1 corneas were not irradiated but incubated in the dark without CPZ in the medium; control 2 corneas were also kept in the dark but in the presence of CPZ; control 3 corneas were irradiated with no CPZ in the medium. Cellular damage was not seen in the three types of control corneas, but in the experimental corneas the endothelial cells showed extensive disruption of the cell membrane and some deterioration of the intracellular components. Our study confirmed that HRSEM is a satisfactory new technique for visualizing damage of the intracellular organelles of corneal endothelium.

  5. Converging Stereotactic Radiotherapy Using Kilovoltage X-Rays: Experimental Irradiation of Normal Rabbit Lung and Dose-Volume Analysis With Monte Carlo Simulation

    SciTech Connect

    Kawase, Takatsugu; Kunieda, Etsuo Deloar, Hossain M.; Tsunoo, Takanori; Seki, Satoshi; Oku, Yohei; Saitoh, Hidetoshi; Saito, Kimiaki; Ogawa, Eileen N.; Ishizaka, Akitoshi; Kameyama, Kaori; Kubo, Atsushi

    2009-10-01

    Purpose: To validate the feasibility of developing a radiotherapy unit with kilovoltage X-rays through actual irradiation of live rabbit lungs, and to explore the practical issues anticipated in future clinical application to humans through Monte Carlo dose simulation. Methods and Materials: A converging stereotactic irradiation unit was developed, consisting of a modified diagnostic computed tomography (CT) scanner. A tiny cylindrical volume in 13 normal rabbit lungs was individually irradiated with single fractional absorbed doses of 15, 30, 45, and 60 Gy. Observational CT scanning of the whole lung was performed every 2 weeks for 30 weeks after irradiation. After 30 weeks, histopathologic specimens of the lungs were examined. Dose distribution was simulated using the Monte Carlo method, and dose-volume histograms were calculated according to the data. A trial estimation of the effect of respiratory movement on dose distribution was made. Results: A localized hypodense change and subsequent reticular opacity around the planning target volume (PTV) were observed in CT images of rabbit lungs. Dose-volume histograms of the PTVs and organs at risk showed a focused dose distribution to the target and sufficient dose lowering in the organs at risk. Our estimate of the dose distribution, taking respiratory movement into account, revealed dose reduction in the PTV. Conclusions: A converging stereotactic irradiation unit using kilovoltage X-rays was able to generate a focused radiobiologic reaction in rabbit lungs. Dose-volume histogram analysis and estimated sagittal dose distribution, considering respiratory movement, clarified the characteristics of the irradiation received from this type of unit.

  6. Pneumatic Valve Operated by Multiplex Pneumatic Transmission

    NASA Astrophysics Data System (ADS)

    Nishioka, Yasutaka; Suzumori, Koichi; Kanda, Takefumi; Wakimoto, Shuichi

    A pneumatic system has several advantages, which are cheapness, lightweight, and reliability to human and environment. These advantages are adapted to some research areas, such as industrial lines, medical and nursing cares, and rehabilitation tools. However, the pneumatic system needs several devices; compressor, air tube, and control valve. This research aim to downsize pneumatic system. In this paper, a new method of multiplex pneumatic transmission for multi-pneumatic servo system is proposed. The valve for this system consists of two vibrators supported by springs, which was designed with simple and cheap structure. The working principle of the valve is vibrators resonance from multiplex pneumatic transmission and it is possible to work as ON/OFF valves without electric wire. Dynamic simulation was used to confirm the working principle of the resonance driving system. A prototype device confirming the principle was designed and developed based on the simulation. The experiments show that this new control system works very well to control two separated valves through single pneumatic tube.

  7. Topical Administration of the Mitochondrial PTP Opening Inhibitor CoQ10 Prevents Apoptotic Cell Death Induced by UVC-Irradiation in Rat's Corneas and Rabbit's Retinas

    NASA Astrophysics Data System (ADS)

    Papucci, Laura; Witort, Ewa; Schiavone, Nicola; Donnini, Martino; Lapucci, Andrea; Lulli, Matteo; Lazzarano, Stefano; Simoncini, Madine; Mazzoni, Tiziano; Falciani, Piergiuseppe; Capaccioli, Sergio

    2008-06-01

    We have previously demonstrated in vitro that ubiquitous free radical scavenger coenzyme Q10 prevents keratocyte apoptosis induced by excimer laser irradiation more efficiently than other antioxidants. We showed that its anti apoptotic property is independent of its free radical scavenging ability and is related to direct inhibition of PTP (permeability transition pore) opening and mitochondrial depolarization. Here, we demonstrate in vivo, that CoQ10 can efficiently protect rat's corneas and rabbit's retinas irradiated with UVC. Therefore, we propose application of CoQ10 as countermeasure to prevent micro radiation-induced eye damage during interplanetary space exploration.

  8. Effect of low-level laser therapy irradiation and Bio-Oss graft material on the osteogenesis process in rabbit calvarium defects: a double blind experimental study.

    PubMed

    Rasouli Ghahroudi, Amir Alireza; Rokn, Amir Reza; Kalhori, Katayoun A M; Khorsand, Afshin; Pournabi, Alireza; Pinheiro, A L B; Fekrazad, Reza

    2014-05-01

    This study aims to assess the effect of low-level laser therapy (LLLT) irradiation and Bio-Oss graft material on the osteogenesis process in the rabbit calvarium defects. Twelve white male New Zealand rabbits were included in this study. Four 8-mm diameter identical defects were prepared on each rabbit's calvarium. One site was left as an untreated control (C), the second site was filled with Bio-Oss (B), the third site was treated with laser irradiation (L), and the fourth site treated with Bio-Oss and laser irradiation (B + L). In the laser group, a diode laser (wavelength 810 nm, output power 300 mW, irradiation mode CW, energy density 4 J/cm2) was applied immediately after surgery and then one other day for the next 20 days. After 4 and 8 weeks, the animals were sacrificed and histological and histomorphometric examinations were performed and the data were subjected to Friedman and repeated measurements ANOVA tests. Significant differences were not found regarding inflammation severity, foreign body reactions, and vitality of newly formed bone on 4th and 8th week after operation. The mean amount of new bone was 15.83 and 18.5% in the controls on the 4th and 8th week; 27.66 and 25.16% in the laser-irradiated group; 35.0 and 41.83% in Bio-Oss and 41.83 and 47.0% in the laser + Bio-Oss treated specimens with significant statistical differences (p <0.05). Application of LLLT in combination with Bio-Oss® can promote bone healing. Therefore, LLLT may be clinically beneficial in promoting bone formation in skeletal defects.

  9. Rotary pneumatic valve

    DOEpatents

    Hardee, Harry C.

    1991-01-01

    A rotary pneumatic valve which is thrust balanced and the pneumatic pressure developed produces only radial loads on the valve cylinder producing negligible resistance and thus minimal torque on the bearings of the valve. The valve is multiplexed such that at least two complete switching cycles occur for each revolution of the cylinder spindle.

  10. Basic Pneumatics. Instructor's Guide.

    ERIC Educational Resources Information Center

    Fessehaye, Michael

    This instructor's guide is designed for use by industrial vocational teachers in teaching a course on basic pneumatics. Covered in the individual units are the following topics: an introduction to pneumatics (including the operation of a service station hoist); fundamentals and physical laws; air compressors (positive displacement compressors;…

  11. The influence of intravenous laser irradiation of blood on some metabolic and functional parameters in intact rabbits and experimental cerebral ischaemia

    NASA Astrophysics Data System (ADS)

    Nechipurenko, N.; Vasilevskaya, L.; Musienko, J.; Maslova, G.

    2007-07-01

    It has been studied the intravenous laser irradiation of blood (ILIB) influence with helium-neon laser (HNL) of 630 nm wavelength on some of lipid peroxidation (LPO) and antioxidant system (AOS) findings, aside-base status (ABS) and blood oxygen transport (BOT), state of dermal microhaemodynamics (MGD) in the intact rabbits and after modeling of local ischemia of brain (LIB). Depending on conditions of organism functioning (norm or brain ischaemia) ILIB has resulted in stimulating or normalizing effects on the whole metabolic and microhaemocirculation processes which had been studied during our investigation. It is discussed the mechanisms of pathogenetic directivity of ILIB influence in cerebral ischaemia

  12. Combination of BMP-2-releasing gelatin/β-TCP sponges with autologous bone marrow for bone regeneration of X-ray-irradiated rabbit ulnar defects.

    PubMed

    Yamamoto, Masaya; Hokugo, Akishige; Takahashi, Yoshitake; Nakano, Takayoshi; Hiraoka, Masahiro; Tabata, Yasuhiko

    2015-07-01

    The objective of this study is to evaluate the feasibility of gelatin sponges incorporating β-tricalcium phosphate (β-TCP) granules (gelatin/β-TCP sponges) to enhance bone regeneration at a segmental ulnar defect of rabbits with X-ray irradiation. After X-ray irradiation of the ulnar bone, segmental critical-sized defects of 20-mm length were created, and bone morphogenetic protein-2 (BMP-2)-releasing gelatin/β-TCP sponges with or without autologous bone marrow were applied to the defects to evaluate bone regeneration. Both gelatin/β-TCP sponges containing autologous bone marrow and BMP-2-releasing sponges enhanced bone regeneration at the ulna defect to a significantly greater extent than the empty sponges (control). However, in the X-ray-irradiated bone, the bone regeneration either by autologous bone marrow or BMP-2 was inhibited. When combined with autologous bone marrow, the BMP-2 exhibited significantly high osteoinductivity, irrespective of the X-ray irradiation. The bone mineral content at the ulna defect was similar to that of the intact bone. It is concluded that the combination of bone marrow with the BMP-2-releasing gelatin/β-TCP sponge is a promising technique to induce bone regeneration at segmental bone defects after X-ray irradiation.

  13. Pneumatic sample-transfer system for use with the Lawrence Livermore National Laboratory rotating target neutron source (RTNS-I)

    SciTech Connect

    Williams, R.E.

    1981-07-01

    A pneumatic sample-transfer system is needed to be able to rapidly retrieve samples irradiated with 14-MeV neutrons at the Rotating Target Neutron Source (RTNS-I). The rabbit system, already in place for many years, has been refurbished with modern system components controlled by an LSI-11 minicomputer. Samples can now be counted three seconds after an irradiation. There are many uses for this expanded 14-MeV neutron activation capability. Several fission products difficult to isolate from mixed fission fragments can be produced instead through (n,p) or (n,..cap alpha..) reactions with stable isotopes. Mass-separated samples of Nd, Mo, and Se, for example, can be irradiated to produce Pr, Nb, and As radionuclides sufficient for decay scheme studies. The system may also be used for multielement fast-neutron activation analysis because the neutron flux is greater than 2 x 10/sup 11/ n/cm/sup 2/-sec. Single element analyses of Si and O are also possible. Finally, measurements of fast-neutron cross sections producing short-lived activation products can be performed with this system. A description of the rabbit system and instructions for its use are presented in this report.

  14. Induction of skin papillomas in the rabbit, Oryctologus cuniculus, by bites of a blood-sucking insect, Cimex lectularius, irradiated by gamma rays

    SciTech Connect

    el-Mofty, M.M.; Sakr, S.A.; Younis, M.W. )

    1989-11-01

    Bed bugs, Cimex lectularius, irradiated with gamma rays were allowed to suck blood from shaved areas of the skin of rabbits, Oryctolagus cuniculus, 2 times/week for 5 months and then once weekly for another 5 months. This significantly induced the formation of skin papillomas and sweat gland hyperplasia in five out of nine experimental animals. It is speculated that the saliva of the irradiated bugs was activated by gamma rays and was responsible for the induction of skin papillomas. Because bed bugs play a significant role in the transmission of virus, it is also speculated that there is a virus in the saliva of bugs; this virus may be activated by gamma radiation and causes the development of papillomas in the skin.

  15. Pneumatic soil removal tool

    DOEpatents

    Neuhaus, John E.

    1992-01-01

    A soil removal tool is provided for removing radioactive soil, rock and other debris from the bottom of an excavation, while permitting the operator to be located outside of a containment for that excavation. The tool includes a fixed jaw, secured to one end of an elongate pipe, which cooperates with a movable jaw pivotably mounted on the pipe. Movement of the movable jaw is controlled by a pneumatic cylinder mounted on the pipe. The actuator rod of the pneumatic cylinder is connected to a collar which is slidably mounted on the pipe and forms part of the pivotable mounting assembly for the movable jaw. Air is supplied to the pneumatic cylinder through a handle connected to the pipe, under the control of an actuator valve mounted on the handle, to provide movement of the movable jaw.

  16. Pneumatic soil removal tool

    DOEpatents

    Neuhaus, J.E.

    1992-10-13

    A soil removal tool is provided for removing radioactive soil, rock and other debris from the bottom of an excavation, while permitting the operator to be located outside of a containment for that excavation. The tool includes a fixed jaw, secured to one end of an elongate pipe, which cooperates with a movable jaw pivotably mounted on the pipe. Movement of the movable jaw is controlled by a pneumatic cylinder mounted on the pipe. The actuator rod of the pneumatic cylinder is connected to a collar which is slidably mounted on the pipe and forms part of the pivotable mounting assembly for the movable jaw. Air is supplied to the pneumatic cylinder through a handle connected to the pipe, under the control of an actuator valve mounted on the handle, to provide movement of the movable jaw. 3 figs.

  17. Pneumatic squirming robot based on flexible pneumatic actuator

    NASA Astrophysics Data System (ADS)

    Yang, Qinghua; Zhang, Libin; Bao, Guanjun; Ruan, Jian

    2005-12-01

    The design of a kind of pneumatic squirming robot is presented. It is based on the use of flexible pneumatic actuator. The flexible pneumatic actuator was made of caoutchouc. Its working principle is described. The structure, working principle, pneumatic and electrical control system of the pneumatic squirming robot are designed. All of the actuator's driving and squirming parts are composed of pneumatic elements. The vacuum osculums, which act as feet, are connected to the flexible pneumatic actuator. When the vacuum pumps operate, vacuum will be produced in the corresponding osculums, which can adsorb on the contacting surface and orient the robot. The actuator, operating under air pressure, drives the robot. By controlling the vacuum pumps and the actuator, straight and bending squirming of this robot can be obtained.

  18. Pneumatic stowing seals mines

    SciTech Connect

    Brezovec, D.

    1983-11-01

    A pneumatic stowing technique has been used in the US to seal entries to abandoned mines. Limestone mixed with dry cement or bentonite is blown into the opening. Sealing can be accomplished in much less time than with traditional concrete block/clay plug methods.

  19. Computation of temperature elevation in rabbit eye irradiated by 2.45-GHz microwaves with different field configurations.

    PubMed

    Hirata, Akimasa; Watanabe, Soichi; Taki, Masao; Fujiwara, Osamu; Kojima, Masami; Sasaki, Kazuyuki

    2008-02-01

    This study calculated the temperature elevation in the rabbit eye caused by 2.45-GHz near-field exposure systems. First, we calculated specific absorption rate distributions in the eye for different antennas and then compared them with those observed in previous studies. Next, we re-examined the temperature elevation in the rabbit eye due to a horizontally-polarized dipole antenna with a C-shaped director, which was used in a previous study. For our computational results, we found that decisive factors of the SAR distribution in the rabbit eye were the polarization of the electromagnetic wave and antenna aperture. Next, we quantified the eye average specific absorption rate as 67 W kg(-1) for the dipole antenna with an input power density at the eye surface of 150 mW cm(-2), which was specified in the previous work as the minimum cataractogenic power density. The effect of administrating anesthesia on the temperature elevation was 30% or so in the above case. Additionally, the position where maximum temperature in the lens appears is discussed due to different 2.45-GHz microwave systems. That position was found to appear around the posterior of the lens regardless of the exposure condition, which indicates that the original temperature distribution in the eye was the dominant factor.

  20. Pneumatic osteoarthritis knee brace.

    PubMed

    Stamenović, Dimitrije; Kojić, Milos; Stojanović, Boban; Hunter, David

    2009-04-01

    Knee osteoarthritis is a chronic disease that necessitates long term therapeutic intervention. Biomechanical studies have demonstrated an improvement in the external adduction moment with application of a valgus knee brace. Despite being both efficacious and safe, due to their rigid frame and bulkiness, current designs of knee braces create discomfort and difficulties to patients during prolonged periods of application. Here we propose a novel design of a light osteoarthritis knee brace, which is made of soft conforming materials. Our design relies on a pneumatic leverage system, which, when pressurized, reduces the excessive loads predominantly affecting the medial compartment of the knee and eventually reverses the malalignment. Using a finite-element analysis, we show that with a moderate level of applied pressure, this pneumatic brace can, in theory, counterbalance a greater fraction of external adduction moment than the currently existing braces.

  1. Pneumatic conveyance apparatus and process

    DOEpatents

    Heckendorn, Frank M.; Matzolf, Athneal D.; Hera, Kevin R.

    2010-05-04

    A pneumatic nozzle capable of removing dry solid debris, liquids, and mixtures of solid and liquid waste is provided. The pneumatic nozzle uses a pressurized gas stream to push materials through the nozzle. The force of a pressurized gas stream provides a partial vacuum to allow material to be introduced into an opening of a nozzle via a slight suction force. Thereafter, individual particles and materials introduced into the pneumatic nozzle are pushed by a stream of pressurized gas through the nozzle.

  2. Reconstruction of irradiated bone segmental defects with a biomaterial associating MBCP+(R), microstructured collagen membrane and total bone marrow grafting: an experimental study in rabbits.

    PubMed

    Jégoux, Franck; Goyenvalle, Eric; Cognet, Ronan; Malard, Olivier; Moreau, Francoise; Daculsi, Guy; Aguado, Eric

    2009-12-15

    The bone tissue engineering models used today are still a long way from any oncologic application as immediate postimplantation irradiation would decrease their osteoinductive potential. The aim of this study was to reconstruct a segmental critical size defect in a weight-bearing bone irradiated after implantation. Six white New Zealand rabbits were immediately implanted with a biomaterial associating resorbable collagen membrane EZ(R) filled and micro-macroporous biphasic calcium phosphate granules (MBCP+(R)). After a daily schedule of radiation delivery, and within 4 weeks, a total autologous bone marrow (BM) graft was injected percutaneously into the center of the implant. All the animals were sacrificed at 16 weeks. Successful osseous colonization was found to have bridged the entire length of the defects. Identical distribution of bone ingrowth and residual ceramics at the different levels of the implant suggests that the BM graft plays an osteoinductive role in the center of the defect. Periosteum-like formation was observed at the periphery, with the collagen membrane most likely playing a role. This model succeeded in bridging a large segmental defect in weight-bearing bone with immediate postimplantation fractionated radiation delivery. This has significant implications for the bone tissue engineering approach to patients with cancer-related bone defects.

  3. Pneumatic Pellet-Transporting System

    NASA Technical Reports Server (NTRS)

    Wood, George; Pugsley, Robert A.

    1992-01-01

    Pneumatic system transports food pellets to confined animals. Flow of air into venturi assembly entrains round pellets, drawing them from reservoir into venturi for transport by airflow. Pneumatic pellet-transporting system includes venturi assembly, which creates flow of air that draws pellets into system.

  4. Pneumatization of the sphenoid sinus.

    PubMed

    Terra, E R; Guedes, F R; Manzi, F R; Bóscolo, F N

    2006-01-01

    This paper describes a case of pneumatization of the sphenoid sinus in the pterygoid process and greater wing of the sphenoid bone, observed on a panoramic radiograph. Conventional radiographs and computerized tomography in axial and coronal sections confirmed the presence of the pneumatization of these structures.

  5. Rigidified pneumatic composites

    NASA Astrophysics Data System (ADS)

    van Dessel, Steven

    2000-10-01

    The overall objective of the research presented in this dissertation was to address global issues of adequate housing for all and the need for more sustainable human settlement. In order to address these, the emerging technology of rigidified pneumatic composites was investigated. Rigidified pneumatic composites (RPC) are defined as thin flexible membrane structures that are pneumatically deployed. After deployment, these structures harden due to chemical or physical change of the membrane. Because of this change, these structures do no longer require pneumatic pressure to maintain their shape. For the first time, a systematic listing of the various means available to develop polymeric materials useful in RPC technology is presented. With the aim to reduce the cost of RPC structures, a new material was proposed, developed, and evaluated. This material involved the formation of a semi-interpenetrating polymer network based on poly vinyl chloride and an acrylate based reactive plasticizer. The economical and environmental performances of RPC structures using this new material were assessed by means of a case study. In this study, the performance of RPC technology was compared with that of a typical wood light frame structure in the application of a small single-family house. The study indicated that the cost of ownership in present day value for the RPC structure was approximately 33% less than the cost of a comparable wood light frame structure. The study also indicated that significant environmental benefits exist with the use of RPC structures. It was found that the RPC structure used significantly less resources compared to the wood light frame structure. About 3.5 times less materials coming from non-renewable fossil resources, about 2.5 times less materials coming from trees, and about 19 times less materials coming from inorganic resources was used in the RPC structure relative to the wood light frame structure. The study concluded with pointing out various

  6. Common-path Fourier domain optical coherence tomography of irradiated human skin and ventilated isolated rabbit lungs

    NASA Astrophysics Data System (ADS)

    Popp, A.; Wendel, M.; Knels, L.; Knuschke, P.; Mehner, M.; Koch, T.; Boller, D.; Koch, P.; Koch, E.

    2005-08-01

    A compact common path Fourier domain optical coherence tomography (FD-OCT) system based on a broadband superluminescence diode is used for biomedical imaging. The epidermal thickening of human skin after exposure to ultraviolet radiation is measured to proof the feasibility of FD-OCT for future substitution of invasive biopsies in a long term study on natural UV skin protection. The FD-OCT system is also used for imaging lung parenchyma. FD-OCT images of a formalin fixated lung show the same alveolar structure as scanning electron microscopy images. In the ventilated and blood-free perfused isolated rabbit lung FD-OCT is used for real-time cross-sectional image capture of alveolar mechanics throughout tidal ventilation. The alveolar mechanics changing from alternating recruitment-derecruitment at zero positive end-expiratory pressure (PEEP) to persistent recruitment after applying a PEEP of 5 cm H2O is observed in the OCT images.

  7. Pneumatic energy storage

    SciTech Connect

    Flowers, D.

    1995-09-19

    An essential component to hybrid electric and electric vehicles is energy storage. A power assist device could also be important to many vehicle applications. This discussion focuses on the use of compressed gas as a system for energy storage and power in vehicle systems. Three possible vehicular applications for which these system could be used are discussed in this paper. These applications are pneumatically driven vehicles, series hybrid electric vehicles, and power boost for electric and conventional vehicles. One option for a compressed gas system is as a long duration power output device for purely pneumatic and hybrid cars. This system must provide enough power and energy to drive under normal conditions for a specified time or distance. The energy storage system for this use has the requirement that it will be highly efficient, compact, and have low mass. Use of a compressed gas energy storage as a short duration, high power output system for conventional motor vehicles could reduce engine size or reduce transient emissions. For electric vehicles this kind of system could lengthen battery life by providing battery load leveling during accelerations. The system requirements for this application are that it be compact and have low mass. The efficiency of the system is a secondary consideration in this application.

  8. Automatic irradiation control by an optical feedback technique for selective retina treatment (SRT) in a rabbit model

    NASA Astrophysics Data System (ADS)

    Seifert, Eric; Roh, Young-Jung; Fritz, Andreas; Park, Young Gun; Kang, Seungbum; Theisen-Kunde, Dirk; Brinkmann, Ralf

    2013-06-01

    Selective Retina Therapy (SRT) targets the Retinal Pigment Epithelium (RPE) without effecting neighboring layers as the photoreceptors or the choroid. SRT related RPE defects are ophthalmoscopically invisible. Owing to this invisibility and the variation of the threshold radiant exposure for RPE damage the treating physician does not know whether the treatment was successful or not. Thus measurement techniques enabling a correct dosing are a demanded element in SRT devices. The acquired signal can be used for monitoring or automatic irradiation control. Existing monitoring techniques are based on the detection of micro-bubbles. These bubbles are the origin of RPE cell damage for pulse durations in the ns and μs time regime 5μs. The detection can be performed by optical or acoustical approaches. Monitoring based on an acoustical approach has already been used to study the beneficial effects of SRT on diabetic macula edema and central serous retinopathy. We have developed a first real time feedback technique able to detect micro-bubble induced characteristics in the backscattered laser light fast enough to cease the laser irradiation within a burst. Therefore the laser energy within a burst of at most 30 pulses is increased linearly with every pulse. The laser irradiation is ceased as soon as micro-bubbles are detected. With this automatic approach it was possible to observe invisible lesions, an intact photoreceptor layer and a reconstruction of the RPE within one week.

  9. Origin of postcranial skeletal pneumaticity in dinosaurs.

    PubMed

    Wedel, Mathew J

    2006-06-01

    The sauropodomorph Thecodontosaurus caducus and theropod Coelophysis bauri are the earliest known dinosaurs with postcranial skeletal pneumaticity. In both taxa, postcranial pneumatic features are confined to the cervical vertebrae. This distribution of pneumaticity in the skeleton is most consistent with pneumatization by diverticula of cervical air sacs similar to those of birds. Other hypotheses, including pneumatization by diverticula of the lungs, larynx and trachea, or cranial air spaces, are less well-supported.

  10. Pneumatic stowing seals mines

    SciTech Connect

    Brezovec, D.

    1983-11-01

    A mechanized technique to seal abandoned mines has been used successfully to close 13 openings at Duquesne Light Co.'s mined-out Warwick No. 2 mine, near Greensboro, Pa. The mechanized system, which uses a pneumatic stower and crushed limestone, closed the entries more economically and in less time than it would have taken to install traditional concrete block stopping and clay plug seals, according to John C. Draper. Draper, a mining engineer with Duquesne Light's coal department, was in charge of installing the Warwick seals in a Bureau of Mines-sponsored field test on the pneumatic sealing technique. The lowest estimated cost for installing conventional stopping and plug closures for the 13 Warwick openings was $225,000, says Draper, while the openings were closed using the mechanized system for $245,000. Draper says the newer stopping cost more in the instance because work was stopped often to gather information for the experiment. The experimental closures were installed in 38 days. The job would have taken at least 149 days if traditional closures were being installed, Draper say. To install a traditional concrete block/clay plug closure, the mine opening must be cleaned thoroughly and the roof must be supported for some 3 ft from the outside. Then a solid wall or stopping must be built 25 ft from the surface and the entry must be packed with clay to the surface. Much of this job requires workers to remain underground. In pneumatic stowing, 1 1/2-in. crushed limestone with fines is conveyed through a pipeline and into the mine opening under low air pressure. Watertight seals can be installed by blowing about 10 ft of rock into the opening against the top to act as roof support. Safety posts are installed and about 10 or 15 ft of mine entry is cleaned. About 2 in. of raw cement or bentonite is placed on the floor and limestone mixed with dry cement or bentonite is blown into the opening.

  11. Instrumented Pneumatic-Impact Tester

    NASA Technical Reports Server (NTRS)

    Shelley, Richard M.; Armendariz, Norman

    1993-01-01

    Pneumatic-impact tester is small pressure chamber equipped with specimen holder and optical port. Device designed to test susceptibility of polymeric material to ignition by "pneumatic impact" in high-pressure gaseous oxygen. Used to determine differences among susceptibilities to ignition of different materials and of different batches of nominally same material proposed for use in systems containing pressurized oxygen. Also used to show characteristics of ignition and combustion.

  12. Experimental Plan for EDF Energy Creep Rabbit Graphite Irradiations- Rev. 2 (replaces Rev. 0 ORNL/TM/2013/49).

    SciTech Connect

    Burchell, Timothy D

    2014-07-01

    The experimental results obtained here will assist in the development and validation of future models of irradiation induced creep of graphite by providing the following data: Inert creep stain data from low to lifetime AGR fluence Inert creep-property data (especially CTE) from low to lifetime AGR fluence Effect of oxidation on creep modulus (by indirect comparison with experiment 1 and direct comparison with experiment 3 NB. Experiment 1 and 3 are not covered here) Data to develop a mechanistic understanding, including oAppropriate creep modulus (including pinning and high dose effects on structure) oInvestigation of CTE-creep strain behavior under inert conditions oInformation on the effect of applied stress/creep strain on crystallite orientation (requires XRD) oEffect of creep strain on micro-porosity (requires tomography & microscopy) This document describes the experimental work planned to meet the requirements of project technical specification [1] and EDF Energy requests for additional Pre-IE work. The PIE work is described in detail in this revision (Section 8 and 9).

  13. Rabbit medicine.

    PubMed

    Jordan, Dinah G

    2007-01-01

    When filling prescriptions for a rabbit, it is important to know whether the rabbit is a pet or is being raised as a source of food for human consumption. Several drugs widely used for pet rabbits are prohibited from exralabel use in animals raised for food production. The list of banned drugs should always be perused prior to filling a prescription for a rabbit being raised for food production. Since no veterinary-approved products exist for rabbits and most medications must be compounded, pharmacists are likely to encounter prescriptions for rabbits in their practice. A basic understanding of rabbit anatomy, physiolgy and common diseases will assist pharmacists in distinguishing between safe and dangerous drugs for administration to rabbits.

  14. 49 CFR 236.590 - Pneumatic apparatus.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 4 2011-10-01 2011-10-01 false Pneumatic apparatus. 236.590 Section 236.590..., Train Control and Cab Signal Systems Inspection and Tests; Locomotive § 236.590 Pneumatic apparatus. Automatic train stop, train control, or cab signal pneumatic apparatus shall be inspected, cleaned, and...

  15. 49 CFR 236.590 - Pneumatic apparatus.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Pneumatic apparatus. 236.590 Section 236.590..., Train Control and Cab Signal Systems Inspection and Tests; Locomotive § 236.590 Pneumatic apparatus. Automatic train stop, train control, or cab signal pneumatic apparatus shall be inspected, cleaned, and...

  16. Pneumatic Spoiler Controls Airfoil Lift

    NASA Technical Reports Server (NTRS)

    Hunter, D.; Krauss, T.

    1991-01-01

    Air ejection from leading edge of airfoil used for controlled decrease of lift. Pneumatic-spoiler principle developed for equalizing lift on helicopter rotor blades. Also used to enhance aerodynamic control of short-fuselage or rudderless aircraft such as "flying-wing" airplanes. Leading-edge injection increases maneuverability of such high-performance fixed-wing aircraft as fighters.

  17. Pneumatic gap sensor and method

    DOEpatents

    Bagdal, Karl T.; King, Edward L.; Follstaedt, Donald W.

    1992-01-01

    An apparatus and method for monitoring and maintaining a predetermined width in the gap between a casting nozzle and a casting wheel, wherein the gap is monitored by means of at least one pneumatic gap sensor. The pneumatic gap sensor is mounted on the casting nozzle in proximity to the casting surface and is connected by means of a tube to a regulator and a transducer. The regulator provides a flow of gas through a restictor to the pneumatic gap sensor, and the transducer translates the changes in the gas pressure caused by the proximity of the casting wheel to the pneumatic gap sensor outlet into a signal intelligible to a control device. The relative positions of the casting nozzle and casting wheel can thereby be selectively adjusted to continually maintain a predetermined distance between their adjacent surfaces. The apparatus and method enables accurate monitoring of the actual casting gap in a simple and reliable manner resistant to the extreme temperatures and otherwise hostile casting environment.

  18. Pneumatic gap sensor and method

    DOEpatents

    Bagdal, K.T.; King, E.L.; Follstaedt, D.W.

    1992-03-03

    An apparatus and method for monitoring and maintaining a predetermined width in the gap between a casting nozzle and a casting wheel, wherein the gap is monitored by means of at least one pneumatic gap sensor. The pneumatic gap sensor is mounted on the casting nozzle in proximity to the casting surface and is connected by means of a tube to a regulator and a transducer. The regulator provides a flow of gas through a restictor to the pneumatic gap sensor, and the transducer translates the changes in the gas pressure caused by the proximity of the casting wheel to the pneumatic gap sensor outlet into a signal intelligible to a control device. The relative positions of the casting nozzle and casting wheel can thereby be selectively adjusted to continually maintain a predetermined distance between their adjacent surfaces. The apparatus and method enables accurate monitoring of the actual casting gap in a simple and reliable manner resistant to the extreme temperatures and otherwise hostile casting environment. 6 figs.

  19. Model for pneumatic pellet injection

    SciTech Connect

    Hogan, J.T.; Milora, S.L.; Schuresko, D.D.

    1983-07-01

    A hydrodynamic code has been developed to model the performance of pneumatic pellet injection systems. The code describes one dimensional, unsteady compressible gas dynamics, including gas friction and heat transfer to the walls in a system with variable area. The mass, momentum, and energy equations are solved with an iterated Lax-Wendroff scheme with additional numerical viscosity. The code is described and comparisons with experimental data are presented.

  20. Electric versus hydraulics versus pneumatics

    SciTech Connect

    Not Available

    1985-01-01

    This book presents a collection of papers from a conference which considered the advantages and disadvantages of electric, hydraulic and pneumatic drives and actuators. The volume follows on the success of the 1983 conference on electric and hydraulic drives. Topics considered include fork lift trucks - an ideal application for regenerative transmissions; a hybrid-electric power system with hydrostatic transmission; electrics and hydraulics on roadheader machinery; hydraulic, electrical, pneumatic control - which way to go. an electrically-powered servo to drive the two axes of a missile launching platform - pros and cons when compared with the traditional hydraulic solution; the encapsulation of a novel intrinsically safe displacement transducer; mobile cryogenic pumping systems; automation of a wood-turning machine, hydraulic or electric. The choice of a servo motor for a specific application; developments in the design and control of pneumatic linear actuators; compressed air purification for instrumentation in the high technology industries; trends in prime mover choice for powered hand tools; and choosing the drive system for the right application.

  1. Note: A fast pneumatic sample-shuttle with attenuated shocks

    SciTech Connect

    Biancalana, Valerio; Dancheva, Yordanka; Stiaccini, Leonardo

    2014-03-15

    We describe a home-built pneumatic shuttle suitable for the fast displacement of samples in the vicinity of a highly sensitive atomic magnetometer. The samples are magnetized at 1 T using a Halbach assembly of magnets. The device enables the remote detection of free-induction-decay in ultra-low-field and zero-field nuclear magnetic resonance (NMR) experiments, in relaxometric measurements and in other applications involving the displacement of magnetized samples within time intervals as short as a few tens of milliseconds. Other possible applications of fast sample shuttling exist in radiological studies, where samples have to be irradiated and then analyzed in a cold environment.

  2. 21 CFR 878.5910 - Pneumatic tourniquet.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ...) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Therapeutic Devices § 878.5910 Pneumatic tourniquet... patient's limb and inflated to reduce or totally occlude circulation during surgery. (b)...

  3. 21 CFR 878.5910 - Pneumatic tourniquet.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ...) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Therapeutic Devices § 878.5910 Pneumatic tourniquet... patient's limb and inflated to reduce or totally occlude circulation during surgery. (b)...

  4. 21 CFR 878.5910 - Pneumatic tourniquet.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ...) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Therapeutic Devices § 878.5910 Pneumatic tourniquet... patient's limb and inflated to reduce or totally occlude circulation during surgery. (b)...

  5. 21 CFR 878.5910 - Pneumatic tourniquet.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ...) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Therapeutic Devices § 878.5910 Pneumatic tourniquet... patient's limb and inflated to reduce or totally occlude circulation during surgery. (b)...

  6. 21 CFR 878.5910 - Pneumatic tourniquet.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ...) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Therapeutic Devices § 878.5910 Pneumatic tourniquet... patient's limb and inflated to reduce or totally occlude circulation during surgery. (b)...

  7. RANGE INCREASER FOR PNEUMATIC GAUGES

    DOEpatents

    Fowler, A.H.; Seaborn, G.B. Jr.

    1960-09-27

    An improved pneumatic gage is offered in which the linear range has been increased without excessive air consumption. This has been accomplished by providing an expansible antechamber connected to the nozzle of the gage so that the position of the nozzle with respect to the workpiece is varied automatically by variation in pressure within the antechamber. This arrangement ensures that the nozzle-to-workpiece clearance is maintained within certain limits, thus obtaining a linear relation of air flow to nozzle-to-workpiece clearance over a wider range.

  8. A Study of Gas Economizing Pneumatic Cylinder

    NASA Astrophysics Data System (ADS)

    Li, T. C.; Wu, H. W.; Kuo, M. J.

    2006-10-01

    The pneumatic cylinder is the most typical actuator in the pneumatic equipment, and its mechanism is so simple that it is often used to operate point to point driving without the feedback loop in various automatic machines. But, the energy efficiency of pneumatic system is very poor compared with electrical systems and hydraulic systems. So, it is very important to discuss the energy saving for the pneumatic cylinder systems. In this thesis, we proposed three methods to apply the reduction in the air consumed for pneumatic cylinder systems. An air charge accumulator is used to absorb the exhausted compress air and a boost valve boosted the air to the higher pressure for used again. From the experiments, the direct used cylinder exhaust air may save about 40% of compress air.

  9. An animal model for the study of neuromuscular injury induced beneath and distal to a pneumatic tourniquet.

    PubMed

    Pedowitz, R A; Rydevik, B L; Gershuni, D H; Hargens, A R

    1990-11-01

    A well-controlled animal model is presented for the study of neuromuscular injury induced by a pneumatic tourniquet. This model comprises a curved tourniquet surrounded by a stiff exterior shell, both of which were specifically designed to fit the conical and oblong shape of the rabbit hindlimb. Computed tomographic imaging was used to assess transverse tissue displacement induced by tourniquet compression. The curved tourniquet/shell configuration occluded the distal arterial blood flow to the extremity at a significantly lower cuff inflation pressure than a straight tourniquet of equal width. The magnitude and distribution of tissue pressures in the subcutaneous and deep tissues beneath the tourniquet were similar to those recorded in previous human cadaver studies of tourniquet compression. This animal model will facilitate the quantitation and analysis of tissue injury induced beneath and distal to a pneumatic tourniquet. Such data can help define the critical pressure and time limits for the safe use of pneumatic tourniquets in extremity surgery.

  10. Milestone M3FT-15OR0203112. Build redesigned HFIR rabbit capsules and make ready for insertion for irradiation in HFIR

    SciTech Connect

    Howard, Richard H; McDuffee, Joel Lee; Okuniewski, Maria A.

    2015-09-01

    This report details the fabrication and delivery of two Fuel Cycle Research and Development irradiation capsules (FCRP20 and FCRP03), with associated quality assurance documentation, to the High Flux Isotope Reactor. The capsules and documentation were delivered by September 30, 2015, thus meeting the deadline for milestone M3FT-15OR0203112. These irradiation experiments irradiate metal parallelepiped specimens that may consist of various compositions including uranium metal, steel, etc. This document contains a copy of the completed capsule fabrication request sheets, which detail all constituent components, pertinent drawings, etc., along with a detailed summary of the capsule assembly process performed by the Thermal Hydraulics and Irradiation Engineering Group (THIEG) in the Reactor and Nuclear Systems Division. A complete fabrication package record is maintained by THIEG and is available upon request.

  11. Pneumatic Variable Series Elastic Actuator.

    PubMed

    Zheng, Hao; Wu, Molei; Shen, Xiangrong

    2016-08-01

    Inspired by human motor control theory, stiffness control is highly effective in manipulation and human-interactive tasks. The implementation of stiffness control in robotic systems, however, has largely been limited to closed-loop control, and suffers from multiple issues such as limited frequency range, potential instability, and lack of contribution to energy efficiency. Variable-stiffness actuator represents a better solution, but the current designs are complex, heavy, and bulky. The approach in this paper seeks to address these issues by using pneumatic actuator as a variable series elastic actuator (VSEA), leveraging the compressibility of the working fluid. In this work, a pneumatic actuator is modeled as an elastic element with controllable stiffness and equilibrium point, both of which are functions of air masses in the two chambers. As such, for the implementation of stiffness control in a robotic system, the desired stiffness/equilibrium point can be converted to the desired chamber air masses, and a predictive pressure control approach is developed to control the timing of valve switching to obtain the desired air mass while minimizing control action. Experimental results showed that the new approach in this paper requires less expensive hardware (on-off valve instead of proportional valve), causes less control action in implementation, and provides good control performance by leveraging the inherent dynamics of the actuator.

  12. Caudal pneumaticity and pneumatic hiatuses in the sauropod dinosaurs Giraffatitan and Apatosaurus.

    PubMed

    Wedel, Mathew J; Taylor, Michael P

    2013-01-01

    Skeletal pneumaticity is found in the presacral vertebrae of most sauropod dinosaurs, but pneumaticity is much less common in the vertebrae of the tail. We describe previously unrecognized pneumatic fossae in the mid-caudal vertebrae of specimens of Giraffatitan and Apatosaurus. In both taxa, the most distal pneumatic vertebrae are separated from other pneumatic vertebrae by sequences of three to seven apneumatic vertebrae. Caudal pneumaticity is not prominent in most individuals of either of these taxa, and its unpredictable development means that it may be more widespread than previously recognised within Sauropoda and elsewhere in Saurischia. The erratic patterns of caudal pneumatization in Giraffatitan and Apatosaurus, including the pneumatic hiatuses, show that pneumatic diverticula were more broadly distributed in the bodies of the living animals than are their traces in the skeleton. Together with recently published evidence of cryptic diverticula--those that leave few or no skeletal traces--in basal sauropodomorphs and in pterosaurs, this is further evidence that pneumatic diverticula were widespread in ornithodirans, both across phylogeny and throughout anatomy.

  13. Caudal Pneumaticity and Pneumatic Hiatuses in the Sauropod Dinosaurs Giraffatitan and Apatosaurus

    PubMed Central

    Wedel, Mathew J.; Taylor, Michael P.

    2013-01-01

    Skeletal pneumaticity is found in the presacral vertebrae of most sauropod dinosaurs, but pneumaticity is much less common in the vertebrae of the tail. We describe previously unrecognized pneumatic fossae in the mid-caudal vertebrae of specimens of Giraffatitan and Apatosaurus. In both taxa, the most distal pneumatic vertebrae are separated from other pneumatic vertebrae by sequences of three to seven apneumatic vertebrae. Caudal pneumaticity is not prominent in most individuals of either of these taxa, and its unpredictable development means that it may be more widespread than previously recognised within Sauropoda and elsewhere in Saurischia. The erratic patterns of caudal pneumatization in Giraffatitan and Apatosaurus, including the pneumatic hiatuses, show that pneumatic diverticula were more broadly distributed in the bodies of the living animals than are their traces in the skeleton. Together with recently published evidence of cryptic diverticula—those that leave few or no skeletal traces—in basal sauropodomorphs and in pterosaurs, this is further evidence that pneumatic diverticula were widespread in ornithodirans, both across phylogeny and throughout anatomy. PMID:24205162

  14. Pneumatic tools for vitreoretinal surgery.

    PubMed

    Romano, Mario R; Vallejo-Garcia, Jose Luis; Randazzo, Alessandro; Vinciguerra, Paolo

    2012-01-01

    One of the difficulties of microsurgery is learning how to control physiological tremors. The pneumatic tool eliminates the physiological tremor, but no tactile feedback is provided. The manual tremor when closing the forceps is completely eliminated and the exact target can be more easily grabbed. Forceps closure pressure can rise up to 50 psi, whereas the scissors can be used in two modes: multicut and proportional. When performing bimanual surgery the pedal range is divided into two steps: in the first step, the forceps are controlled, and in the second step, the forceps remain closed. At the same time the scissors start to work in the preselected mode. No adverse events occurred and no iatrogenic retinal breaks were produced. Precision and control sensation were a grateful surprise.

  15. F-15 Pneumatic Forbody Controls

    NASA Technical Reports Server (NTRS)

    1994-01-01

    A series of test have been conducted in the Langley 30-by-60 Foot Tunnel to determine the effectiveness of several forebody control devices on a 10-percent-scale model of the F-15E. These test are part of a cooperative research program with the U.S. Air Force Wright Laboratory and the McDonnell Aircraft Company to determine the suitability of applying forebody controls to the F-15E aircraft. The forebody controls under investigation included mechanical concepts, such as deflectable strakes and rotating-randome devices, and pneumatic concepts, such as slotted-nozzle blowing. All these concepts are designed to provide increased maneuverability by enhancing yaw control at high angles of attack where conventional rudders become ineffective. Results from the tests show that the F-15E is well suited for the application of forebody-controls technology. After conducting a number of parametric variations, several mechanical and pneumatic forebody control options were identified that were capable of providing high levels of yaw control while minimizing the impact on other aircraft systems. Other desirable characteristics exhibited by these concepts were that the control effectiveness was retained over wide ranges of sideslip and that the level of yawing moment was easily controlled by varying either the mechanical deflection or the blowing rate. Subsequent piloted simulation studies conducted by the McDonnell Aircraft Company have shown that these improved levels of yaw control would significantly enhance the maneuverability of the aircraft. The promising results that were obtained during these tests have spawned interest in a flight-test program and possible future application to the F-15E aircraft.

  16. A pneumatic transfer system for special form {sup 252}Cf

    SciTech Connect

    Gehrke, R.J.; Berry, S.M.; Grafwallner, E.G.; Hoggan, J.M.

    1996-09-01

    A pneumatic transfer system has been developed for use with series 100 Special Form {sup 252}Cf. It was developed to reduce the exposure to personnel handling sources of {sup 252}Cf with masses up to 150 {micro}g by permitting remotely activated two-way transfer between the storage container and the irradiation position. The pneumatic transfer system also permits transfers for reproducible repetitive irradiation periods. In addition to the storage container equipped with quick-release fittings, the transfer system consists of an irradiation station, a control box with momentary contact switches to activate the air-pressure control valves and indicators to identify the location of the source, and connecting air hose and electrical wire. A source of 20 psig air and 110 volt electrical power are required for operation of the transfer system which can be easily moved and set up by one individual in 5 to 10 minutes. Tests have shown that rarely does a source become lodged in the transfer tubing, but two methods have been developed to handle incomplete transfers of the {sup 252}Cf source. The first method consists of closing one air vent to allow a pressure impulse to propel the source to the opposite side. The second method applies to those {sup 252}Cf capsules with a threaded or tapped end to which a small ferromagnetic piece can be attached; an incompletely transferred source in the transfer tube can then be guided to a position of safety by surrounding the transfer tubing containing the capsule with a horseshoe magnet attached to the end of a long pole.

  17. Pneumatic robotic systems for upper limb rehabilitation.

    PubMed

    Morales, Ricardo; Badesa, Francisco Javier; García-Aracil, Nicolás; Sabater, José María; Pérez-Vidal, Carlos

    2011-10-01

    The aim of rehabilitation robotic area is to research on the application of robotic devices to therapeutic procedures. The goal is to achieve the best possible motor, cognitive and functional recovery for people with impairments following various diseases. Pneumatic actuators are attractive for robotic rehabilitation applications because they are lightweight, powerful, and compliant, but their control has historically been difficult, limiting their use. This article first reviews the current state-of-art in rehabilitation robotic devices with pneumatic actuation systems reporting main features and control issues of each therapeutic device. Then, a new pneumatic rehabilitation robot for proprioceptive neuromuscular facilitation therapies and for relearning daily living skills: like taking a glass, drinking, and placing object on shelves is described as a case study and compared with the current pneumatic rehabilitation devices.

  18. Pneumatic fracturing of low permeability media

    SciTech Connect

    Schuring, J.R.

    1996-08-01

    Pneumatic fracturing of soils to enhance the removal and treatment of dense nonaqueous phase liquids is described. The process involves gas injection at a pressure exceeding the natural stresses and at a flow rate exceeding the permeability of the formation. The paper outlines geologic considerations, advantages and disadvantages, general technology considerations, low permeability media considerations, commercial availability, efficiency, and costs. Five case histories of remediation using pneumatic fracturing are briefly summarized. 11 refs., 2 figs., 1 tab.

  19. Promising pneumatic punchers for borehole drilling

    SciTech Connect

    A.A. Lipin

    2005-03-15

    The state of borehole drilling by downhole pneumatic punchers and their potential use in open and underground mining as well as in exploration for reliable sampling are analyzed. Performance specification is presented for the new-generation pneumatic punchers equipped with a pin tool, effectively operating at a compressed-air pressure of 0.5-0.7 MPa, and with an additional extended exhaust from the power stroke chamber during working cycle.

  20. Rabbit hematology.

    PubMed

    Marshall, Kemba L

    2008-09-01

    Using laboratory animal medicine as an established resource, companion animal veterinarians have access to many physiologic and basic science studies that we can now merge with our clinical impressions. By working with reference laboratories, companion animal veterinarians are poised to accelerate our knowledge of the normal rabbit rapidly. The aim of this article is to discuss normal hematopoiesis and infectious and metabolic diseases that specifically target the hemolymphatic system. Additionally, photographic representation of cell types is provided.

  1. Histophysiology of cellular immunity reactions in B-cell deprived rabbits. An X-irradiation model for delineation of an 'isolated T-cell system'.

    PubMed

    Veldman, J E; Keuning, F J

    1978-10-16

    Three times sublethal total body X-irradiation with thymus shielding--at 2 weeks' intervals--delineated a temporarily B-cell deprived animal model, only reconstituted with recently thymus-derived cells. The thymusdependent areas of peripheral lymphoid tissue-repleted with T-cells--are described. The cellular immune capacity of these animals with an "isolated T-cell system" was analyzed by means of skin allografting. Histological and autoradiographic studies were performed in draining lymph nodes after a variety of antigenic stimuli: skin allografts, S. java vaccin, horse-gamma-globulin, horse spleen ferritin and a contact sensitizer (Oxazolone).

  2. Evaluation of posterior clinoid process pneumatization by multidetector computed tomography.

    PubMed

    Burulday, Veysel; Akgül, Mehmet Hüseyin; Muluk, Nuray Bayar; Ozveren, Mehmet Faik; Kaya, Ahmet

    2016-10-21

    In the present study, we investigated the types and ratio of posterior clinoid process (PCP) pneumatization in paranasal sinus multidetector computed tomography (MDCT). Paranasal MDCT images of 541 subjects (227 males, 314 females), between 15 and 65 years old, were included into the study. Pneumatization of anterior clinoid process and pneumatization types (I, II, or III) were evaluated in the males and females. PCP pneumatization was detected in 20.7 % of the males and 11.5 % of the females. Right, left, and bilateral PCP pneumatizations were detected in 7.9, 5.7, and 7.0 % of the males and 2.9, 3.2, and 4.5 % of the females, respectively. PCP pneumatization of the males is significantly higher than the females. The most detected type of pneumatization was type I (61.2 %) for all groups. In right, left, and bilateral pneumatizations separately, type I pneumatization was the most detected pneumatization type with the ratio of the 70.4, 65.2, and 50.0 %, respectively. In males, type I (61.7 %), and similarly in females, type I (60.6 %) pneumatization were detected more. Type II and type III pneumatizations were detected in decreasing order in both groups. In younger subjects, pneumatization of posterior clinoid process was found as higher, and in older subjects, PCP pneumatization was found as lower. Sclerosis process related to the aging may be responsible for the lower pneumatization ratios in older subjects. Structure of the surrounding regions of PCP is important for surgical procedures related to cavernous sinus, basilar apex aneurysms, and mass lesions. Preoperative radiological examinations are useful for operative planning. Any anomalies to PCP can cause unnecessary injury to the neurovascular complex structure around the cavernous sinus or postclinoidectomy CSF fistulas. Posterior clinoidectomies should be avoided in patients with type III PCP pneumatization to prevent CSF fistulas.

  3. [Development of an adaptive pneumatic tourniquet].

    PubMed

    Liu, Hongyun; Zhang, Zhengbo; Li, Kaiyuan; Guo, Junyan; Wang, Weidong

    2012-06-01

    A new adaptive pneumatic tourniquet was developed for limb operation and first-aid. The crucial hardware circuits of the adaptive pneumatic tourniquet were designed based on the microprocessor C8051F340 and blood pressure module CSN602, software was programmed and an experiment was carried out for verifying the system. Results showed that the prototype could measure accurately systolic blood pressure, heart rate and other relative parameters and the designed device could adjust tourniquet cuff's pressure through inflation and deflation according to systolic blood pressure and limb circumference. This designed system integrated the advantages of the adaptive pneumatic tourniquet, and could be used for controlling life-threatening extremity hemorrhage operation and maintaining a bloodless opeation field.

  4. Pneumatic Rupture of Rectosigmoid; a Case Report.

    PubMed

    Montazeri, Mohammad; Farhangi, Bahman; Montazeri, Mahmood

    2014-01-01

    Pneumatic rectosigmoid rapture is usually occurred following the inappropriate fun by direct entering a high volume of the air through the pneumatic device to the anus. Such an event was reported for the first time in 1904 by Stone. Diagnosis and treatment of such injuries are often delayed because of some social limitations and preventing the patient form explaining the event. Colon sigmoid rupture and pneumoperitoneum is one of the most dangerous and life treating complications of entering a high volume of the air to the rectum in a short time. There are only a few reports regarding the similar cases. Here, a case of pneumatic rectosigmoid rapture was reported in a 53 year-old male following an inappropriate fun.

  5. 7 CFR 3201.86 - Pneumatic equipment lubricants.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 7 Agriculture 15 2014-01-01 2014-01-01 false Pneumatic equipment lubricants. 3201.86 Section 3201... PROCUREMENT Designated Items § 3201.86 Pneumatic equipment lubricants. (a) Definition. Lubricants designed... this part, will give a procurement preference for qualifying biobased pneumatic equipment...

  6. 7 CFR 3201.86 - Pneumatic equipment lubricants.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 7 Agriculture 15 2013-01-01 2013-01-01 false Pneumatic equipment lubricants. 3201.86 Section 3201... PROCUREMENT Designated Items § 3201.86 Pneumatic equipment lubricants. (a) Definition. Lubricants designed... this part, will give a procurement preference for qualifying biobased pneumatic equipment...

  7. 21 CFR 870.2780 - Hydraulic, pneumatic, or photoelectric plethysmographs.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Hydraulic, pneumatic, or photoelectric... § 870.2780 Hydraulic, pneumatic, or photoelectric plethysmographs. (a) Identification. A hydraulic... using hydraulic, pneumatic, or photoelectric measurement techniques. (b) Classification. Class...

  8. 21 CFR 870.2780 - Hydraulic, pneumatic, or photoelectric plethysmographs.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Hydraulic, pneumatic, or photoelectric... § 870.2780 Hydraulic, pneumatic, or photoelectric plethysmographs. (a) Identification. A hydraulic... using hydraulic, pneumatic, or photoelectric measurement techniques. (b) Classification. Class...

  9. 21 CFR 870.2780 - Hydraulic, pneumatic, or photoelectric plethysmographs.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Hydraulic, pneumatic, or photoelectric... § 870.2780 Hydraulic, pneumatic, or photoelectric plethysmographs. (a) Identification. A hydraulic... using hydraulic, pneumatic, or photoelectric measurement techniques. (b) Classification. Class...

  10. 21 CFR 870.2780 - Hydraulic, pneumatic, or photoelectric plethysmographs.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Hydraulic, pneumatic, or photoelectric... § 870.2780 Hydraulic, pneumatic, or photoelectric plethysmographs. (a) Identification. A hydraulic... using hydraulic, pneumatic, or photoelectric measurement techniques. (b) Classification. Class...

  11. 21 CFR 870.2780 - Hydraulic, pneumatic, or photoelectric plethysmographs.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Hydraulic, pneumatic, or photoelectric... § 870.2780 Hydraulic, pneumatic, or photoelectric plethysmographs. (a) Identification. A hydraulic... using hydraulic, pneumatic, or photoelectric measurement techniques. (b) Classification. Class...

  12. 21 CFR 882.4370 - Pneumatic cranial drill motor.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Pneumatic cranial drill motor. 882.4370 Section... drill motor. (a) Identification. A pneumatic cranial drill motor is a pneumatically operated power source used with removable rotating surgical cutting tools or drill bits on a patient's skull....

  13. 21 CFR 882.4370 - Pneumatic cranial drill motor.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Pneumatic cranial drill motor. 882.4370 Section... drill motor. (a) Identification. A pneumatic cranial drill motor is a pneumatically operated power source used with removable rotating surgical cutting tools or drill bits on a patient's skull....

  14. 21 CFR 882.4370 - Pneumatic cranial drill motor.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Pneumatic cranial drill motor. 882.4370 Section... drill motor. (a) Identification. A pneumatic cranial drill motor is a pneumatically operated power source used with removable rotating surgical cutting tools or drill bits on a patient's skull....

  15. 49 CFR 236.817 - Switch, electro-pneumatic.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 4 2013-10-01 2013-10-01 false Switch, electro-pneumatic. 236.817 Section 236.817 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION... Switch, electro-pneumatic. A switch operated by an electro-pneumatic switch-and-lock movement....

  16. 49 CFR 236.817 - Switch, electro-pneumatic.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 4 2014-10-01 2014-10-01 false Switch, electro-pneumatic. 236.817 Section 236.817 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION... Switch, electro-pneumatic. A switch operated by an electro-pneumatic switch-and-lock movement....

  17. 49 CFR 236.817 - Switch, electro-pneumatic.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 4 2012-10-01 2012-10-01 false Switch, electro-pneumatic. 236.817 Section 236.817 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION... Switch, electro-pneumatic. A switch operated by an electro-pneumatic switch-and-lock movement....

  18. PNEUMATIC PUMP TEST FOR DESIGN OF SOIL VACUUM EXTRACTION

    EPA Science Inventory

    In-situ pneumatic pumping tests were performed to estimate the pneumatic permeability at a site containing soils contaminated with aviation gasoline. Determination of pneumatic permeability was necessary to evaluate soil-air discharge or pore volume exchange rates. Pressure propa...

  19. 49 CFR 236.817 - Switch, electro-pneumatic.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Switch, electro-pneumatic. 236.817 Section 236.817 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION... Switch, electro-pneumatic. A switch operated by an electro-pneumatic switch-and-lock movement....

  20. 49 CFR 236.817 - Switch, electro-pneumatic.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 4 2011-10-01 2011-10-01 false Switch, electro-pneumatic. 236.817 Section 236.817 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION... Switch, electro-pneumatic. A switch operated by an electro-pneumatic switch-and-lock movement....

  1. 21 CFR 882.4370 - Pneumatic cranial drill motor.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Pneumatic cranial drill motor. 882.4370 Section 882.4370 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... drill motor. (a) Identification. A pneumatic cranial drill motor is a pneumatically operated...

  2. 21 CFR 882.4370 - Pneumatic cranial drill motor.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Pneumatic cranial drill motor. 882.4370 Section 882.4370 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... drill motor. (a) Identification. A pneumatic cranial drill motor is a pneumatically operated...

  3. Pneumatically switchable graded index metamaterial lens

    NASA Astrophysics Data System (ADS)

    Khodasevych, I. E.; Shadrivov, I. V.; Powell, D. A.; Rowe, W. S. T.; Mitchell, A.

    2013-01-01

    A low-profile pneumatically switchable graded index metamaterial lens operating at 9 GHz is proposed and practically demonstrated. An effective graded refractive index is engineered using an array of electric resonators of differing resonant frequency. Normal orientation of the resonators allows ultrathin single metamaterial layer lens design. Switching between focusing and non-focusing states is practically demonstrated by shorting the gaps in split ring resonators and eliminating the resonant response and the phase difference between the elements across the lens with pneumatically actuated metal patches that are pressed against the gaps of the resonators as the pressure in the chamber is reduced.

  4. Guidelines help design pneumatic control systems

    SciTech Connect

    Curry, R.N.

    1981-01-26

    The three areas of particular interest to the gas-transmission engineer about pneumatic-instrument-operated control valves are (1) the fail-position probability of a system, (2) the designated action required for each component in the pneumatic circuit, and (3) the schematically defined position of each component. Compared with self-operated control valves, the instrument-operated systems perform many more functions; they can control the flow and the volume or flow-volume combinations, with both pressure override and underride, and will adapt conveniently to remote operation. Schematic diagrams illustrate the numerous system designs possible for pressure-regulation, flow-control, and relief-valve duties.

  5. RABBIT POX

    PubMed Central

    Rosahn, Paul D.; Hu, Ch'uan-K'uei

    1935-01-01

    Observations on an epidemic of rabbit pox occurring in an isolated animal room during the winter of 1933–34 are reported. The clinical manifestations, consisting of a generalized papular eruption involving the skin and mucous membranes, together with blepharitis, ophthalmia, nasal discharge and lymphadenopathy were essentially similar to those noted in a pox epidemic of the previous year. This was true in general also of the pathological findings except that vacuolization, local necrosis and vesicle formation were seen in the epidermis, while in the previous year the microscopic pathology in the skin was confined to the corium. Evidence was presented indicating that the infection can be transmitted through the medium of a personal carrier, and that transmission in this manner can occur during the incubation period or before a definite diagnosis is possible. The findings also demonstrated that the etiological agents responsible for the disease reported here and that of the previous year were immunologically related, and that the immunity in recovered animals effectively persisted during the entire period for which data are available, 9 to 12 months. It appeared also that young animals suckling an immune doe were more refractory to the development of the lesions of rabbit pox than were the young of susceptible does. PMID:19870418

  6. Myocardial hydroxyproline reduced by early administration of methylprednisolone or ibuprofen to rabbits with radiation-induced heart disease

    SciTech Connect

    Reeves, W.C.; Cunningham, D.; Schwiter, E.J.; Abt, A.; Skarlatos, S.; Wood, M.A.; Whitesell, L.

    1982-05-01

    The ability of methylprednisolone (MP) and ibuprofen (IB) to reduce the severity of the late state of radiation-induced heart disease was assessed in 57 New Zealand white rabbits. Before and shortly after cardiac irradiation, 15 rabbits received i.v. MP, 30 mg/kg twice daily for 3 days, and 15 others received IB, 12.5 mg/kg twice daily for 2 days. No drug administered to 14 irradiated rabbits, and neither irradiation nor drugs were administered to 13 rabbits that served as controls. All 15 rabbits treated with MP and 13 of the 15 treated with IB lived for 100 days. Only seven of the untreated, irradiated rabbits lived that long. Longevity of each treated group of rabbits was better (p < 0.01 and 0.05) than that of the untreated, irradiated rabbits. Surviving rabbits were killed 100 days after irradiation. Pericarditis (p < 0.05) and pericardial effusion (p < 0.01) were less frequent in the treated, irradiated groups than in the untreated, irradiated rabbits. At least some rabbits in each irradiated group had microscopic evidence of myocardial fibrosis. The fibrosis was quantitated by determination of myocardial hydroxyproline concentrations (MHP). MHP concentration in the untreated, irradiated rabbits was greater than in those treated with MP (p < 0.05) or IB (p < 0.01) and in the untreated, unirradiated rabbits (p < 0.01). Early administrative of MP or IB retarded the development of myocardial fibrosis, pericarditis and pericardial effusin, and improved survival in this experimental model of radiation-induced heart disease.

  7. Myocardial hydroxyproline reduced by early administration of methylprednisolone or ibuprofen to rabbits with radiation-induced heart disease

    SciTech Connect

    Reeves, W.C.; Cunningham, D.; Schwiter, E.J.; Abt, A.; Skarlatos, S.; Wood, M.A.; Whitesell, L.

    1982-05-01

    The ability of methylprednisolone (MP) and ibuprofen (IB) to reduce the severity of the late state of radiation-induced heart disease was assessed in 57 New Zealand white rabbits. Before and shortly after cardiac irradiation, 15 rabbits received i.v. MP, 30 mg/kg twice daily for 3 days, and 15 others received IB, 12.5 mg/kg twice daily for 2 days. No drug was administered to 14 irradiated rabbits, and neither irradiation nor drugs were administered to 13 rabbits that served as controls, All 15 rabbits treated with MP and 13 of the 15 treated with IB lived for 100 days. Only seven of the untreated, irradiated rabbits lived that long. Longevity of each treated group of rabbits was better (p less than 0.01 and 0.05) than that of the untreated, irradiated rabbits. Surviving rabbits were killed 100 days after irradiation. Pericarditis (p less than 0.05) and pericardial effusion (p less than 0.01) were less frequent in the treated, irradiated groups than in the untreated, irradiated rabbits. At least some rabbits in each irradiated group had microscopic evidence of myocardial fibrosis. The fibrosis was quantitated by determination of myocardial hydroxyproline concentrations (MHP). MHP concentration in the untreated, irradiated rabbits was greater than in those treated with MP (p less than 0.05) or IB (p less than 0.01) and in the untreated, unirradiated rabbits (p less than 0.01). Early administration of MP or IB retarded the development of myocardial fibrosis, pericarditis and pericardial effusion, and improved survival in this experimental model of radiation-induced heart disease.

  8. Vertebral Pneumaticity in the Ornithomimosaur Archaeornithomimus (Dinosauria: Theropoda) Revealed by Computed Tomography Imaging and Reappraisal of Axial Pneumaticity in Ornithomimosauria

    PubMed Central

    Watanabe, Akinobu; Eugenia Leone Gold, Maria; Brusatte, Stephen L.; Benson, Roger B. J.; Choiniere, Jonah; Davidson, Amy; Norell, Mark A.

    2015-01-01

    Among extant vertebrates, pneumatization of postcranial bones is unique to birds, with few known exceptions in other groups. Through reduction in bone mass, this feature is thought to benefit flight capacity in modern birds, but its prevalence in non-avian dinosaurs of variable sizes has generated competing hypotheses on the initial adaptive significance of postcranial pneumaticity. To better understand the evolutionary history of postcranial pneumaticity, studies have surveyed its distribution among non-avian dinosaurs. Nevertheless, the degree of pneumaticity in the basal coelurosaurian group Ornithomimosauria remains poorly known, despite their potential to greatly enhance our understanding of the early evolution of pneumatic bones along the lineage leading to birds. Historically, the identification of postcranial pneumaticity in non-avian dinosaurs has been based on examination of external morphology, and few studies thus far have focused on the internal architecture of pneumatic structures inside the bones. Here, we describe the vertebral pneumaticity of the ornithomimosaur Archaeornithomimus with the aid of X-ray computed tomography (CT) imaging. Complementary examination of external and internal osteology reveals (1) highly pneumatized cervical vertebrae with an elaborate configuration of interconnected chambers within the neural arch and the centrum; (2) anterior dorsal vertebrae with pneumatic chambers inside the neural arch; (3) apneumatic sacral vertebrae; and (4) a subset of proximal caudal vertebrae with limited pneumatic invasion into the neural arch. Comparisons with other theropod dinosaurs suggest that ornithomimosaurs primitively exhibited a plesiomorphic theropod condition for axial pneumaticity that was extended among later taxa, such as Archaeornithomimus and large bodied Deinocheirus. This finding corroborates the notion that evolutionary increases in vertebral pneumaticity occurred in parallel among independent lineages of bird

  9. Improving dynamic performances of PWM-driven servo-pneumatic systems via a novel pneumatic circuit.

    PubMed

    Taghizadeh, Mostafa; Ghaffari, Ali; Najafi, Farid

    2009-10-01

    In this paper, the effect of pneumatic circuit design on the input-output behavior of PWM-driven servo-pneumatic systems is investigated and their control performances are improved using linear controllers instead of complex and costly nonlinear ones. Generally, servo-pneumatic systems are well known for their nonlinear behavior. However, PWM-driven servo-pneumatic systems have the advantage of flexibility in the design of pneumatic circuits which affects the input-output linearity of the whole system. A simple pneumatic circuit with only one fast switching valve is designed which leads to a quasi-linear input-output relation. The quasi-linear behavior of the proposed circuit is verified both experimentally and by simulations. Closed loop position control experiments are then carried out using linear P- and PD-controllers. Since the output position is noisy and cannot be directly differentiated, a Kalman filter is designed to estimate the velocity of the cylinder. Highly improved tracking performances are obtained using these linear controllers, compared to previous works with nonlinear controllers.

  10. Microfluidic Pneumatic Logic Circuits and Digital Pneumatic Microprocessors for Integrated Microfluidic Systems

    PubMed Central

    Rhee, Minsoung

    2010-01-01

    We have developed pneumatic logic circuits and microprocessors built with microfluidic channels and valves in polydimethylsiloxane (PDMS). The pneumatic logic circuits perform various combinational and sequential logic calculations with binary pneumatic signals (atmosphere and vacuum), producing cascadable outputs based on Boolean operations. A complex microprocessor is constructed from combinations of various logic circuits and receives pneumatically encoded serial commands at a single input line. The device then decodes the temporal command sequence by spatial parallelization, computes necessary logic calculations between parallelized command bits, stores command information for signal transportation and maintenance, and finally executes the command for the target devices. Thus, such pneumatic microprocessors will function as a universal on-chip control platform to perform complex parallel operations for large-scale integrated microfluidic devices. To demonstrate the working principles, we have built 2-bit, 3-bit, 4-bit, and 8-bit microprecessors to control various target devices for applications such as four color dye mixing, and multiplexed channel fluidic control. By significantly reducing the need for external controllers, the digital pneumatic microprocessor can be used as a universal on-chip platform to autonomously manipulate microfluids in a high throughput manner. PMID:19823730

  11. Microfluidic pneumatic logic circuits and digital pneumatic microprocessors for integrated microfluidic systems.

    PubMed

    Rhee, Minsoung; Burns, Mark A

    2009-11-07

    We have developed pneumatic logic circuits and microprocessors built with microfluidic channels and valves in polydimethylsiloxane (PDMS). The pneumatic logic circuits perform various combinational and sequential logic calculations with binary pneumatic signals (atmosphere and vacuum), producing cascadable outputs based on Boolean operations. A complex microprocessor is constructed from combinations of various logic circuits and receives pneumatically encoded serial commands at a single input line. The device then decodes the temporal command sequence by spatial parallelization, computes necessary logic calculations between parallelized command bits, stores command information for signal transportation and maintenance, and finally executes the command for the target devices. Thus, such pneumatic microprocessors will function as a universal on-chip control platform to perform complex parallel operations for large-scale integrated microfluidic devices. To demonstrate the working principles, we have built 2-bit, 3-bit, 4-bit, and 8-bit microprocessors to control various target devices for applications such as four color dye mixing, and multiplexed channel fluidic control. By significantly reducing the need for external controllers, the digital pneumatic microprocessor can be used as a universal on-chip platform to autonomously manipulate microfluids in a high throughput manner.

  12. Distortion Of Pressure Signals In Pneumatic Tubes

    NASA Technical Reports Server (NTRS)

    Whitmore, Stephen A.; Gilyard, Glenn B.; Curry, Robert; Lindsey, William

    1993-01-01

    NASA technical memorandum describes experimental investigation of distorting effects of propagation of pressure signals along narrow pneumatic tubes from pressure-sensing orifices on surfaces of models or aircraft to pressure sensors distant from orifices. Pressure signals distorted principally by frictional damping along walls of tubes and by reflections at orifice and sensor ends.

  13. Pneumatic boot for helicopter rotor deicing

    NASA Technical Reports Server (NTRS)

    Blaha, B. J.; Evanich, P. L.

    1981-01-01

    Pneumatic deicer boots for helicopter rotor blades were tested. The tests were conducted in the 6 by 9 ft icing research tunnel on a stationary section of a UH-IH helicopter main rotor blade. The boots were effective in removing ice and in reducing aerodynamic drag due to ice.

  14. 49 CFR 236.590 - Pneumatic apparatus.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ..., DEPARTMENT OF TRANSPORTATION RULES, STANDARDS, AND INSTRUCTIONS GOVERNING THE INSTALLATION, INSPECTION, MAINTENANCE, AND REPAIR OF SIGNAL AND TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES Automatic Train Stop.... Automatic train stop, train control, or cab signal pneumatic apparatus shall be inspected, cleaned, and...

  15. 49 CFR 236.590 - Pneumatic apparatus.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ..., DEPARTMENT OF TRANSPORTATION RULES, STANDARDS, AND INSTRUCTIONS GOVERNING THE INSTALLATION, INSPECTION, MAINTENANCE, AND REPAIR OF SIGNAL AND TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES Automatic Train Stop.... Automatic train stop, train control, or cab signal pneumatic apparatus shall be inspected, cleaned, and...

  16. 49 CFR 236.590 - Pneumatic apparatus.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ..., DEPARTMENT OF TRANSPORTATION RULES, STANDARDS, AND INSTRUCTIONS GOVERNING THE INSTALLATION, INSPECTION, MAINTENANCE, AND REPAIR OF SIGNAL AND TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES Automatic Train Stop.... Automatic train stop, train control, or cab signal pneumatic apparatus shall be inspected, cleaned, and...

  17. Assessment of Pneumatic Controller Emission Measurements ...

    EPA Pesticide Factsheets

    Oil and Natural Gas (ONG) production facilities have the potential to emit greenhouse gases such as methane (CH4) and other hydrocarbons (HCs) to the atmosphere. ONG production sites have multiple emission sources including storage tank venting, enclosed combustion devices, engine exhaust, pneumatic controllers and uncontrolled leaks. Accounting for up to 37.8 percent of CH4 emissions, pneumatic controllers are one of the most significant sources of CH4 in ONG production field operations. Recent measurement studies used the only commercially-available high volume sampling (HVS) technology (Bacharach Hi Flow Sampler, Bacharach, Inc., New Kensington, PA) to quantify CH4 emission rates of pneumatic devices on ONG production pads and compare to inventory estimates. Other studies indicate that this HVS may malfunction, causing underestimates of emissions in certain scenarios encountered in ONG production and should not be used for some sources such as heavy emissions from condensate storage tanks. The HVS malfunction can occur on relatively large emissions, where the measured leak concentrations exceed 5%, and is ascribed to a sensor transition failure in the instrument. The HVS malfunction is believed to be exacerbated by several factors (large emission rates, amount of non-CH4 HCs in the emission stream, non-optimal HVS calibration frequency, firmware, and emission measurement coupling geometries). The degree to which HVS measurements of emissions from pneumatic co

  18. Analysis of fine coal pneumatic systems

    SciTech Connect

    Mathur, M.P.; Rohatgi, N.D.; Klinzing, G.E.

    1987-01-01

    Many fossil fuel energy processes depend on the movement of solids by pneumatic transport. Despite the considerable amount of work reported in the literature on pneumatic transport, the design of new industrial systems for new products continues to rely to a great extent on empiricism. A pilot-scale test facility has been constructed at Pittsburgh Energy Technology Center (PETC) and is equipped with modern sophisticated measuring techniques (such as Pressure Transducers, Auburn Monitors, Micro Motion Mass flowmeters) and an automatic computer-controlled data acquisition system to study the effects of particle pneumatic transport. Pittsburgh Seam and Montana rosebud coals of varying size consist and moisture content were tested in the atmospheric and pressurized coal flow test loops (AP/CFTL and HP/CFTL) at PETC. The system parameters included conveying gas velocity, injector tank pressure, screw conveyor speed, pipe radius, and pipe bends. In the following report, results from the coal flow tests were presented and analyzed. Existing theories and correlations on two-phase flows were reviewed. Experimental data were compared with values calculated from empirically or theoretically derived equations available in the literature, and new correlations were proposed, when applicable, to give a better interpretation of the data and a better understanding of the various flow regimes involved in pneumatic transport. 55 refs., 56 figs., 6 tabs.

  19. PNEUMATIC FRACTIONATOR FOR CLEANING GINNED LINT

    Technology Transfer Automated Retrieval System (TEKTRAN)

    The pneumatic fractionator has long been used to determine foreign matter content of seed cotton at the USDA Cotton Ginning Laboratories. Spawned from discussions at a Cotton Incorporated Lint Cleaning Summit and building on 1970s research at the Southwestern Cotton Ginning Research Laboratory, an e...

  20. First Approach of Pneumatic Anthropomorphic Hand

    DTIC Science & Technology

    2001-10-25

    weight and minimum consumption, minimum control and natural appearance. Keywords- Anthropomorphic, hand, Pneumatic system, Prosthesis 1. INTRODUCTION...and controls that are compared with the tasks that Human hand can carry out. Each project determines the diverse possibilities of manipulation and...increases the possibilities of acceptance of prosthesis by the user. Multiple degrees of freedom of the prosthesis are difficult to control independently

  1. Enhancing in situ bioremediation with pneumatic fracturing

    SciTech Connect

    Anderson, D.B.; Peyton, B.M.; Liskowitz, J.L.; Fitzgerald, C.; Schuring, J.R.

    1994-04-01

    A major technical obstacle affecting the application of in situ bioremediation is the effective distribution of nutrients to the subsurface media. Pneumatic fracturing can increase the permeability of subsurface formations through the injection of high pressure air to create horizontal fracture planes, thus enhancing macro-scale mass-transfer processes. Pneumatic fracturing technology was demonstrated at two field sites at Tinker Air Force Base, Oklahoma City, Oklahoma. Tests were performed to increase the permeability for more effective bioventing, and evaluated the potential to increase permeability and recovery of free product in low permeability soils consisting of fine grain silts, clays, and sedimentary rock. Pneumatic fracturing significantly improved formation permeability by enhancing secondary permeability and by promoting removal of excess soil moisture from the unsaturated zone. Postfracture airflows were 500% to 1,700% higher than prefracture airflows for specific fractured intervals in the formation. This corresponds to an average prefracturing permeability of 0.017 Darcy, increasing to an average of 0.32 Darcy after fracturing. Pneumatic fracturing also increased free-product recovery rates of number 2 fuel from an average of 587 L (155 gal) per month before fracturing to 1,647 L (435 gal) per month after fracturing.

  2. Evaluation of neutron flux parameters in irradiation sites of research reactor using the Westcott-formalism for the k0 neutron activation analysis method

    NASA Astrophysics Data System (ADS)

    Kasban, H.; Hamid, Ashraf

    2015-12-01

    Instrumental Neutron Activation Analysis using k0 (k0-INAA) method has been used to determine a number of elements in sediment samples collected from El-Manzala Lake in Egypt. k0-INAA according to Westcott's formalism has been implemented using the complete irradiation kit of the fast pneumatic rabbit and some selected manually loaded irradiation sites for short and long irradiation at Egypt Second Research Reactor (ETRR-2). Zr-Au and Co sets as neutron flux monitors are used to determine the neutron flux parameters (f and α) in each irradiation sites. Two reference materials IAEA Soil-7 samples have been inserted and implemented for data validation and an internal monostandard multi monitor used (k0 based IM-NAA). It was given a good agreement between the experimental analyzed values and that obtained of the certified values. The major and trace elements in the sediment samples have been evaluated with the use of Co as an internal and Au as an external monostandard comparators. The concentrations of the elements (Cr, Mn and Zn) in the sediment samples of the present work are discussed regarding to those obtained from other sites.

  3. Pneumatically Actuated Miniature Peristaltic Vacuum Pumps

    NASA Technical Reports Server (NTRS)

    Feldman, Sabrina; Feldman, Jason; Svehla, Danielle

    2003-01-01

    Pneumatically actuated miniature peristaltic vacuum pumps have been proposed for incorporation into advanced miniature versions of scientific instruments that depend on vacuum for proper operation. These pumps are expected to be capable of reaching vacuum-side pressures in the torr to millitorr range (from .133 down to .0.13 Pa). Vacuum pumps that operate in this range are often denoted roughing pumps. In comparison with previously available roughing pumps, these pumps are expected to be an order of magnitude less massive and less power-hungry. In addition, they would be extremely robust, and would operate with little or no maintenance and without need for oil or other lubricants. Portable mass spectrometers are typical examples of instruments that could incorporate the proposed pumps. In addition, the proposed pumps could be used as roughing pumps in general laboratory applications in which low pumping rates could be tolerated. The proposed pumps could be designed and fabricated in conventionally machined and micromachined versions. A typical micromachined version (see figure) would include a rigid glass, metal, or plastic substrate and two layers of silicone rubber. The bottom silicone layer would contain shallow pump channels covered by silicone arches that could be pushed down pneumatically to block the channels. The bottom silicone layer would be covered with a thin layer of material with very low gas permeability, and would be bonded to the substrate everywhere except in the channel areas. The top silicone layer would be attached to the bottom silicone layer and would contain pneumatic- actuation channels that would lie crosswise to the pump channels. This version is said to be micromachined because the two silicone layers containing the channels would be fabricated by casting silicone rubber on micromachined silicon molds. The pneumatic-actuation channels would be alternately connected to a compressed gas and (depending on pump design) either to atmospheric

  4. Viral infections of rabbits.

    PubMed

    Kerr, Peter J; Donnelly, Thomas M

    2013-05-01

    Viral diseases of rabbits have been used historically to study oncogenesis (e.g. rabbit fibroma virus, cottontail rabbit papillomavirus) and biologically to control feral rabbit populations (e.g. myxoma virus). However, clinicians seeing pet rabbits in North America infrequently encounter viral diseases although myxomatosis may be seen occasionally. The situation is different in Europe and Australia, where myxomatosis and rabbit hemorrhagic disease are endemic. Advances in epidemiology and virology have led to detection of other lapine viruses that are now recognized as agents of emerging infectious diseases. Rabbit caliciviruses, related to rabbit hemorrhagic disease, are generally avirulent, but lethal variants are being identified in Europe and North America. Enteric viruses including lapine rotavirus, rabbit enteric coronavirus and rabbit astrovirus are being acknowledged as contributors to the multifactorial enteritis complex of juvenile rabbits. Three avirulent leporid herpesviruses are found in domestic rabbits. A fourth highly pathogenic virus designated leporid herpesvirus 4 has been described in Canada and Alaska. This review considers viruses affecting rabbits by their clinical significance. Viruses of major and minor clinical significance are described, and viruses of laboratory significance are mentioned.

  5. Incidence, radioresistance, and behavior of Psychrobacter spp. in rabbit meat.

    PubMed

    Rodríguez-Calleja, José M; Patterson, Margaret F; García-López, Isabel; Santos, Jesús A; Otero, Andrés; García-López, María-Luisa

    2005-03-01

    The relative incidence of Psychrobacter spp. in rabbit meat, the radioresistance of these bacteria, and the growth of nonirradiated and irradiated psychrobacter isolates, alone and in coculture, during chilled storage of inoculated sterile rabbit meat was investigated. Psychrobacter spp. accounted for 4.2% of the storage psychrotrophic flora of 30 rabbit carcasses. The radiation D10-values of 10 Psychrobacter isolates, irradiated at 4 degrees C in minced rabbit meat, ranged from 0.8 to 2.0 kGy, with significant (P < 0.05) differences among strains. Over 12 days of storage at 4 degrees C, pure cultures of two nonirradiated psychrobacter strains (D10 = 2 kGy) were capable of substantial increases (up to 3 log CFU/g) in sterile rabbit meat, but when the fastest growing strain was cocultured with Pseudomonas fluorescens and Brochothrix thermosphacta isolates, maximum cell densities and growth rates were significantly (P < 0.01) lower. After irradiation (2.5 kGy) of pure cultures in sterile rabbit meat, surviving cells of both Psychrobacter strains decreased for a period of 5 to 7 days and then resumed multiplication that, at day 12, resulted in a similar increase (1.6 to 1.7 log CFU/g) over initial survivor numbers. When irradiated in combination with the spoilage bacteria, one of the strains required 12 days to reach initial numbers. In conclusion, Psychrobacter spp. are radioresistant nonsporeforming bacteria with a low relative incidence among the storage flora of rabbit meat, unable to compete with food spoilage bacteria in this ecosystem and apparently not a major contributor to the spoilage of rabbit meat after irradiation.

  6. A pneumatic cylinder driving polyhedron mobile mechanism

    NASA Astrophysics Data System (ADS)

    Ding, Wan; Kim, Sung-Chan; Yao, Yan-An

    2012-03-01

    A novel pneumatic cylinder driving polyhedron mobile mechanism is proposed in this paper. The mechanism is comprised of 5 tetrahedrons which includes a pneumatic cylinder in each edge. It locomotes by rolling and the rolling principle refers to the center of mass (CM) of the mechanism moved out of the supporting area and let it tip over through the controlling of the motion sequence of these cylinders. Firstly, the mathematical model is built to analysis the relation between the configuration and the CM of the mechanism. Then, a binary control strategy is developed to simplify and improve the control of this mobile mechanism. After that, dynamic simulation is performed to testify the analytical validity and feasibility of the rolling gaits. At last, a prototype is fabricated to achieve the rolling successfully to demonstrate the proposed concept.

  7. Pneumatic conveying of materials at partial gravity

    NASA Technical Reports Server (NTRS)

    Sullivan, Thomas A.; Koenig, Elissa; Knudsen, Christian W.; Gibson, Michael A.

    1992-01-01

    The feasibility of pneumatic transfer for the movement of regolith at a lunar base is evaluated. Operation of pneumatic conveying systems at partial (lunar and Mars) gravity on NASA's KC-135 aircraft allowed the determination of some key parameters necessary for the design of an operable system. Both horizontal and vertical transfer is studied. In the vertical experiment, the choking velocity for 150-micron glass spheres was determined to be 1/2 to 1/3 the velocity required at 1 g. Pressure drops were reduced by roughly the same amount. Determination of the saltation velocity in the horizontal run was problematic, but qualitatively similar results were obtained. Comparison of the partial g results to 1-g behavior and theoretical analysis is made.

  8. Pneumatic Proboscis Heat-Flow Probe

    NASA Technical Reports Server (NTRS)

    Zacny, Kris; Hedlund, Magnus; Mumm, Eric; Shasho, Jeffrey; Chu, Philip; Kumar, Nishant

    2013-01-01

    Heat flow is a fundamental property of a planet, and provides significant constraints on the abundance of radiogenic isotopes, the thermal evolution and differentiation history, and the mechanical properties of the lithosphere. Heat-flow measurements are also essential in achieving at least four of the goals set out by the National Research Council for future lunar exploration. The heat-flow probe therefore directly addresses the goal of the Lunar Geophysical Network, which is to understand the interior structure and composition of the Moon. A key challenge for heat flow measurement is to install thermal sensors to the depths approximately equal to 3 m that are not influenced by the diurnal, annual, and longer-term fluctuations of the surface thermal environment. In addition, once deployed, the heat flow probe should cause little disturbance to the thermal regime of the surrounding regolith. A heat-flow probe system was developed that has two novel features: (1) it utilizes a pneumatic (gas) approach, excavates a hole by lofting the lunar soil out of the hole, and (2) deploys the heat flow probe, which utilizes a coiled up tape as a thermal probe to reach greater than 3-meter depth. The system is a game-changer for small lunar landers as it exhibits extremely low mass, volume, and simple deployment. The pneumatic system takes advantage of the helium gas used for pressurizing liquid propellant of the lander. Normally, helium is vented once the lander is on the surface, but it can be utilized for powering pneumatic systems. Should sufficient helium not be available, a simple gas delivery system may be taken specifically for the heat flow probe. Either way, the pneumatic heat flow probe system would be much lighter than other systems that entirely rely on the electrical power of the lander.

  9. Pneumatic preloaded scanning science launch latch system

    NASA Technical Reports Server (NTRS)

    Kievit, J. C.

    1979-01-01

    A relatively simple system using a preloaded pneumatic piston latch with a pyrotechnic valve release was developed. The system was the only candidate that met all the imposed requirements utilizing reliable state-of-art components. The development of the latch system from its first use on Mariner '69 Mars Flyby Spacecraft through its most recent use on the Voyager Spacecraft that will fly to Jupiter and Saturn is reviewed.

  10. Paranasal pneumatization in extant and fossil Cercopithecoidea.

    PubMed

    Rae, Todd C

    2008-03-01

    Unlike most primates, extant cercopithecoids lack maxillary sinuses, which are pneumatic spaces in the facial skeleton lateral of the nasal cavity proper. Character state analysis of living cercopithecoids across well-supported topologies suggests that the sinus was lost at the origin of the superfamily, only to have evolved again convergently in extant macaques. Recent work has shown that a) the 'early loss' hypothesis is supported by the lack of any pneumatization in Victoriapithecus, a stem cercopithecoid, b) like extant macaques, the fossil cercopithecine Paradolichopithecus shows evidence of presence of the maxillary sinus (MS), and c) unlike extant colobines, the fossil colobine Libypithecus also possesses a maxillary sinus. To more fully assess the pattern of cercopithecoid sinus evolution, fossil taxa from both subfamilies (Colobinae, Cercopithecinae) were examined both visually and by computed tomography (CT). The observations were evaluated according to standard anatomical criteria for defining sinus spaces, and compared with data from all extant Old World monkey genera. Most taxa examined conformed to the pattern already discerned from extant cercopithecoids. Maxillary sinus absence in Theropithecus oswaldi, Mesopithecus, and Rhinocolobus is typical for all extant cercopithecids except Macaca. The fossil macaque Macaca majori possesses a well-developed maxillary sinus, as do all living species of the genus. Cercopithecoides, on the other hand, differs from all extant colobines in possessing a maxillary sinus. Thus, paranasal pneumatization has reemerged a minimum of two and possibly three times in cercopithecoids. The results suggest that maxillary sinus absence in cercopithecoids is due to suppression, rather than complete loss.

  11. Pneumatic compression hemodynamics in total hip arthroplasty.

    PubMed

    Westrich, G H; Specht, L M; Sharrock, N E; Sculco, T P; Salvati, E A; Pellicci, P M; Trombley, J F; Peterson, M

    2000-03-01

    A crossover study was performed to evaluate the effect of several pneumatic compression devices and active dorsoplantar flexion in 10 patients who underwent total hip arthroplasty. Using the Acuson 128XP/10 duplex ultrasound unit with a 5-MHz linear array probe, peak venous velocity and venous volume were assessed above and below the greater saphenous vein and common femoral vein junction. A computer generated randomization table was used to determine the order of the test conditions. The pneumatic compression devices evaluated included two foot pumps, one foot and calf pump, one calf pump, and three calf and thigh pumps. Statistical analyses included analysis of variance and analysis of variance with covariance between devices and patients. The covariates tested were the baseline measurements and the order in which the devices were tested. Differences between devices relate in part to the frequency and rate of inflation and the location and type of compression. Pulsatile calf and foot and calf pneumatic compression with a rapid inflation time produced the greatest increase in peak venous velocity, whereas compression of the calf and thigh showed the greatest increase in venous volume. Because patient and nursing compliance is essential to the success of mechanical prophylaxis for thromboembolic disease, the more simple, yet efficacious, devices that are easier to apply and less cumbersome appear to have a greater likelihood of success. In the active and alert patient, active dorsoplantar flexion should be encouraged.

  12. Development of the prototype pneumatic transfer system for ITER neutron activation systema)

    NASA Astrophysics Data System (ADS)

    Cheon, M. S.; Seon, C. R.; Pak, S.; Lee, H. G.; Bertalot, L.

    2012-10-01

    The neutron activation system (NAS) measures neutron fluence at the first wall and the total neutron flux from the ITER plasma, providing evaluation of the fusion power for all operational phases. The pneumatic transfer system (PTS) is one of the key components of the NAS for the proper operation of the system, playing a role of transferring encapsulated samples between the capsule loading machine, irradiation stations, counting stations, and disposal bin. For the validation and the optimization of the design, a prototype of the PTS was developed and capsule transfer tests were performed with the developed system.

  13. Comparison of pneumatic dilation with pneumatic dilation plus botulinum toxin for treatment of achalasia.

    PubMed

    Bakhshipour, Alireza; Rabbani, Romina; Shirani, Shapoor; Soleimani, Hosein A S L; Mikaeli, Javad

    2010-01-01

    Among the therapeutic options for achalasia are pneumatic dilatation (PD), an appropriate long-term therapy, and botulinum toxin injection (BT) that is a relatively short-term therapy. This study aimed to compare therapeutic effect of repetitive pneumatic dilation with a combined method (botulinum toxin injection and pneumatic dilation) in a group of achalasia patients who are low responder to two initial pneumatic dilations. Thirty-four patients with documented primary achalasia that had low response to two times PD (<50% decrease in symptom score and barium height at 5 minute in timed esophagogram after 3 month of late PD) were randomized to receive pneumatic dilation (n=18) or botulinum toxin injection and pneumatic dilation by four weeks interval (n=16), PD and BT+PD groups respectively. Symptom scores were evaluated before and at 1, 6 and 12 months after treatment. Clinical remission was defined as a decrease in symptom score > or = 50% of baseline. There were no significant differences between the two groups in gender, age and achalasia type. Remission rate of patients in BT-PD group in comparison with PD group were 87.5% vs. 67.1% (P = 0.7), 87.5% vs. 61.1% (P = 0.59) and 87.5% vs. 55.5% (P = 0.53) at 1, 6 and 12 months respectively .There were no major complications in either group. The mean symptom score decreased by 62.71% in the BT-PD group (P < 0.002) and 50.77% in the PD group (P < 0.01) at the end of the first year. Despite a better response rate in BT+PD group, a difference was not statistically significant. A difference may be meaningful if a large numbers of patients are included in the study.

  14. Variant rabbit hemorrhagic disease virus in young rabbits, Spain.

    PubMed

    Dalton, Kevin P; Nicieza, Inés; Balseiro, Ana; Muguerza, María A; Rosell, Joan M; Casais, Rosa; Álvarez, Ángel L; Parra, Francisco

    2012-12-01

    Outbreaks of rabbit hemorrhagic disease have occurred recently in young rabbits on farms on the Iberian Peninsula where rabbits were previously vaccinated. Investigation identified a rabbit hemorrhagic disease virus variant genetically related to apathogenic rabbit caliciviruses. Improved antivirus strategies are needed to slow the spread of this pathogen.

  15. Web-Based Learning and Instruction Support System for Pneumatics

    ERIC Educational Resources Information Center

    Yen, Chiaming; Li, Wu-Jeng

    2003-01-01

    This research presents a Web-based learning and instructional system for Pneumatics. The system includes course material, remote data acquisition modules, and a pneumatic laboratory set. The course material is in the HTML format accompanied with text, still and animated images, simulation programs, and computer aided design tools. The data…

  16. An electromagnetic pneumatic blood pump driver.

    PubMed

    Whalen, R L; Briskman, R N

    1988-01-01

    An electromagnetic pneumatic pump driver has been developed with the goals of enhanced mechanical reliability and simplicity of operation. The new driver eliminates failure prone components such as solenoid valves or pressure regulators common to conventional pneumatic drive systems, has only a single moving part, and provides for closed-loop operation in which stroke volume and dP/dT are controlled on each beat in real time. Power is provided by a high force (178 N) electromagnetic linear actuator. This assembly uses a high energy density neodymium-iron-boron permanent magnet, low loss vanadium alloy pole pieces, and an energized moving coil. The nominal stroke length of the actuator is 1.7 cm. During operation, the moving coil always remains within a fixed annular air gap, resulting in a measured force output versus applied power linearity of better than 92% over its stroke range. The coil is directly attached to the free end of a 10 cm diameter, 21 convolution, welded titanium metal bellows that forms the gas containing element of the system. The comparatively low pressure gradients across the bellows in this application result in a predicted life for the bellows in excess of 10(9) cycles. Bellows position and internal pressure are monitored continuously to control the pneumatic output. The linear actuator total excursion and velocity are adjusted on each beat using a closed-loop servo system. This results in a pump driver with no operator required adjustment of drive pressure. Instead, there are user selected settings of stroke volume, operating mode, and fill sensitivity.(ABSTRACT TRUNCATED AT 250 WORDS)

  17. Pneumatic tire-based piezoelectric power generation

    NASA Astrophysics Data System (ADS)

    Makki, Noaman; Pop-Iliev, Remon

    2011-03-01

    Plug-in Hybrid Electric Vehicles (PHEVs) and Extended Range Electric Vehicles (EREVs) currently mainly rely on Internal Combustion Engines (ICE) utilizing conventional fuels to recharge batteries in order to extend their range. Even though Piezo-based power generation devices have surfaced in recent years harvesting vibration energy, their output has only been sufficient to power up sensors and other such smaller devices. The permanent need for a cleaner power generation technique still remains. This paper investigates the possibility of using piezoceramics for power generation within the vehicle's wheel assembly by exploiting the rotational motion of the wheel and the continuously variable contact point between the pneumatic tire and the road.

  18. Revisiting Pneumatic Nail Gun Trigger Recommendations

    PubMed Central

    Albers, James; Lipscomb, Hester; Hudock, Stephen; Dement, John; Evanoff, Bradley; Fullen, Mark; Gillen, Matt; Kaskutas, Vicki; Nolan, James; Patterson, Dennis; Platner, James; Pompeii, Lisa; Schoenfisch, Ashley

    2015-01-01

    Summary Use of a pneumatic nail gun with a sequential actuation trigger (SAT) significantly diminishes the risk for acute traumatic injury compared to use of a contact actuation trigger (CAT) nail gun. A theoretically-based increased risk of work-related musculoskeletal disorders from use of a SAT nail gun, relative to CAT, appears unlikely and remains unproven. Based on current knowledge, the use of CAT nail guns cannot be justified as a safe alternative to SAT nail guns. This letter provides a perspective of ergonomists and occupational safety researchers recommending the use of the sequential actuation trigger for all nail gun tasks in the construction industry. PMID:26366020

  19. Revisiting Pneumatic Nail Gun Trigger Recommendations.

    PubMed

    Albers, James; Lowe, Brian; Lipscomb, Hester; Hudock, Stephen; Dement, John; Evanoff, Bradley; Fullen, Mark; Gillen, Matt; Kaskutas, Vicki; Nolan, James; Patterson, Dennis; Platner, James; Pompeii, Lisa; Schoenfisch, Ashley

    2015-03-01

    Use of a pneumatic nail gun with a sequential actuation trigger (SAT) significantly diminishes the risk for acute traumatic injury compared to use of a contact actuation trigger (CAT) nail gun. A theoretically-based increased risk of work-related musculoskeletal disorders from use of a SAT nail gun, relative to CAT, appears unlikely and remains unproven. Based on current knowledge, the use of CAT nail guns cannot be justified as a safe alternative to SAT nail guns. This letter provides a perspective of ergonomists and occupational safety researchers recommending the use of the sequential actuation trigger for all nail gun tasks in the construction industry.

  20. Pneumatic Artificial Muscle Actuation and Modeling

    NASA Astrophysics Data System (ADS)

    Leephakpreeda, Thananchai; Wickramatunge, Kanchana C.

    2009-10-01

    A Pneumatic Artificial Muscle (PAM) yields a natural muscle-like actuator with a high force to weight ratio, a soft and flexible structure, and adaptable compliance for a humanoid robot, rehabilitation and prosthetic appliances to the disabled, etc. To obtain optimum design and usage, the mechanical behavior of the PAM need to be understood. In this study, observations of experimental results reveal an empirical model for relations of physical variables, contraction and air pressure within the PAM, as compared to mechanical characteristics, such as stiffness or/and pulling forces of the PAM available now in market.

  1. A comparison between two pneumatic suspension architectures

    NASA Astrophysics Data System (ADS)

    Quaglia, G.; Scopesi, M.; Franco, W.

    2012-04-01

    The aim of this work is to assess and compare the mathematical models of two pneumatic suspension architectures and show how they can converge, after appropriate simplifications, to a general linear form. After making this model dimensionless, it will be used to study, with a transmissibility analysis, the behaviour of a mono-suspension (quarter-car model). Finally, an example of a design process will be shown to highlight the strengths and weaknesses of both architectures and to provide the reader with a practical design tool.

  2. Transforming insect electromyograms into pneumatic muscle control

    NASA Astrophysics Data System (ADS)

    Rutter, Brandon; Mu, Laiyong; Ritzmann, Roy; Quinn, Roger

    2006-05-01

    Robots can serve as hardware models for testing biological hypotheses. Both for this reason and to improve the state of the art of robotics, we strive to incorporate biological principles of insect locomotion into robotic designs. Previous research has resulted in a line of robots with leg designs based on walking and climbing movements of the cockroach Blaberus discoidalis. The current version, Robot V, uses muscle-like Braided Pneumatic Actuators (BPAs). In this paper, we use recorded electromyograms (EMGs) to drive robot joint motion. A muscle activation model was developed that transforms EMGs recorded from behaving cockroaches into appropriate commands for the robot. The transform is implemented by multiplying the EMG by an input gain thus generating an input pressure signal, which is used to drive a one-way closed loop pressure controller. The actuator then can be modeled as a capacitance with input rectification. The actuator exhaust valve is given a leak rate, making the transform a leaky integrator for air pressure, which drives the output force of the actuator. We find parameters of this transform by minimizing the difference between the robot motion produced and that observed in the cockroach. Although we have not reproduced full-amplitude cockroach motion using this robot, results from evaluation on reduced-amplitude cockroach angle data strongly suggest that braided pneumatic actuators can be used as part of a physical model of a biological system.

  3. Pneumatic load compensating or controlling system

    NASA Technical Reports Server (NTRS)

    Rogers, J. R. (Inventor)

    1975-01-01

    A pneumatic load compensating or controlling system for restraining a load with a predetermined force or applying a predetermined force to the load is described; it includes a source of pressurized air, a one-way pneumatic actuator operatively connected to a load, and a fluid conduit fluidically connecting the actuator with the source of pressurized air. The actuator is of the piston and cylinder type, and the end of the fluid conduit is connected to the upper or lower portion of the cylinder whereby the actuator alternatively and selectively restrains the load with a predetermined force or apply a predetermined force to the load. Pressure regulators are included within the system for variably selectively adjusting the pressurized fluid to predetermined values as desired or required; a pressure amplifier is included within the system for multiplying the pressurized values so as to achieve greater load forces. An accumulator is incorporated within the system as a failsafe operating mechanism, and visual and aural alarm devices, operatively associated with pressure detecting apparatus, readily indicate the proper or improper functioning of the system.

  4. Axial and appendicular pneumaticity in Archaeopteryx.

    PubMed Central

    Christiansen, P; Bonde, N

    2000-01-01

    From the time of its discovery in 1860 to this day Archaeopteryx has been essential to our understanding of avian evolution. Despite the great diversity of plesiomorphic avialan (sensu Gauthier 1986) taxa discovered within the last decade, Archaeopteryx remains the most basal avialan taxon. A very unusual feature of extant birds is their lung structure, in which air diverticulae penetrate the bones. This has previously been reported in Archaeopteryx as well, in the cervical vertebrae of the Berlin specimen and in an anterior thoracal vertebra of the Eichstätt specimen. This indicates the presence of a cervical air sac. We show that the London specimen also has pneumatized anterior thoracal vertebrae, and, thus, that this feature was present in the most archaic avialans, as the London and Eichstätt specimens are different species. Furthermore, the pelvis of the London specimen shows clear signs of the presence of an abdominal air sac, indicating that at least two of the five air sacs present in modern birds were also present in Archaeopteryx. Evidence of pubic pneumaticity was also found in the same position in some extant ratites. PMID:11197125

  5. Scaling of pneumatic digital logic circuits.

    PubMed

    Duncan, Philip N; Ahrar, Siavash; Hui, Elliot E

    2015-03-07

    The scaling of integrated circuits to smaller dimensions is critical for achieving increased system complexity and speed. Digital logic circuits composed of pneumatic microfluidic components have to this point been limited to a circuit density of 2-4 gates cm(-2), constraining the complexity of the digital systems that can be achieved. We explored the use of precision machining techniques to reduce the size of pneumatic valves and resistors, and to achieve more accurate and efficient placement of ports and vias. In this way, we attained an order of magnitude increase in circuit density, reaching as high as 36 gates cm(-2). A 12-bit binary counter circuit composed of 96 gates was realized in an area of 360 mm(2). The reduction in size also brought an order of magnitude increase in speed. The frequency of a 13-stage ring oscillator increased from 2.6 Hz to 22.1 Hz, and the maximum clock frequency of a binary counter increased from 1/3 Hz to 6 Hz.

  6. Evaluation of different rotary devices on bone repair in rabbits.

    PubMed

    Ribeiro Junior, Paulo Domingos; Barleto, Christiane Vespasiano; Ribeiro, Daniel Araki; Matsumoto, Mariza Akemi

    2007-01-01

    In oral surgery, the quality of bone repair may be influenced by several factors that can increase the morbidity of the procedure. The type of equipment used for ostectomy can directly affect bone healing. The aim of this study was to evaluate bone repair of mandible bone defects prepared in rabbits using three different rotary devices. Fifteen New Zealand rabbits were randomly assigned to 3 groups (n=5) according to type of rotary device used to create bone defects: I--pneumatic low-speed rotation engine, II--pneumatic high-speed rotation engine, and III--electric low-speed rotation engine. The anatomic pieces were surgically obtained after 2, 7 and 30 days and submitted to histological and morphometric analysis. The morphometric results were expressed as the total area of bone remodeling matrix using an image analysis system. Increases in the bone remodeling matrix were noticed with time along the course of the experiment. No statistically significant differences (p>0.05) were observed among the groups at the three sacrificing time points considering the total area of bone mineralized matrix, although the histological analysis showed a slightly advanced bone repair in group III compared to the other two groups. The findings of the present study suggest that the type of rotary device used in oral and maxillofacial surgery does not interfere with the bone repair process.

  7. Continued Development and Improvement of Pneumatic Heavy Vehicles

    SciTech Connect

    Robert J. Englar

    2005-07-15

    The objective of this applied research effort led by Georgia Tech Research Institute is the application of pneumatic aerodynamic technology previously developed and patented by us to the design of an appropriate Heavy Vehicle (HV) tractor-trailer configuration, and experimental confirmation of this pneumatic configuration's improved aerodynamic characteristics. In Phases I to IV of our previous DOE program (Reference 1), GTRI has developed, patented, wind-tunnel tested and road-tested blown aerodynamic devices for Pneumatic Heavy Vehicles (PHVs) and Pneumatic Sports Utility Vehicles (PSUVs). To further advance these pneumatic technologies towards HV and SUV applications, additional Phase V tasks were included in the first year of a continuing DOE program (Reference 2). Based on the results of the Phase IV full-scale test programs, these Phase V tasks extended the application of pneumatic aerodynamics to include: further economy and performance improvements; increased aerodynamic stability and control; and safety of operation of Pneumatic HVs. Continued development of a Pneumatic SUV was also conducted during the Phase V program. Phase V was completed in July, 2003; its positive results towards development and confirmation of this pneumatic technology are reported in References 3 and 4. The current Phase VI of this program was incrementally funded by DOE in order to continue this technology development towards a second fuel economy test on the Pneumatic Heavy Vehicle. The objectives of this current Phase VI research and development effort (Ref. 5) fall into two categories: (1) develop improved pneumatic aerodynamic technology and configurations on smaller-scale models of the advanced Pneumatic Heavy Vehicle (PHV); and based on these findings, (2) redesign, modify, and re-test the modified full-scale PHV test vehicle. This second objective includes conduct of an on-road preliminary road test of this configuration to prepare it for a second series of SAE Type-U fuel

  8. INFECTIOUS PAPILLOMATOSIS OF RABBITS

    PubMed Central

    Shope, Richard E.; Hurst, E. Weston

    1933-01-01

    A papilloma has been observed in wild cottontail rabbits and has been found to be transmissible to both wild and domestic rabbits. The clinical and pathological pictures of the condition have been described. It has been found that the causative agent is readily filtrable through Berkefeld but not regularly through Seitz filters, that it stores well in glycerol, that it is still active after heating to 67°C. for 30 minutes, but not after heating to 70°C., and that it exhibits a marked tropism for cutaneous epithelium. The activities and properties of the papilloma-producing agent warrant its classification as a filtrable virus. Rabbits carrying experimentally produced papillomata are partially or completely immune to reinfection and, furthermore, their sera partially or completely neutralize the causative virus. The disease is transmissible in series through wild rabbits and virus of wild rabbit origin is readily transmissible to domestic rabbits, producing in this species papillomata identical in appearance with those found in wild rabbits. However, the condition is not transmissible in series through domestic rabbits. The possible significance of this observation has been discussed. The virus of infectious papillomatosis is not related immunologically to either the virus of infectious fibroma or to that of infectious myxoma of rabbits. PMID:19870219

  9. Compensating for pneumatic distortion in pressure sensing devices

    NASA Technical Reports Server (NTRS)

    Whitmore, Stephen A.; Leondes, Cornelius T.

    1990-01-01

    A technique of compensating for pneumatic distortion in pressure sensing devices was developed and verified. This compensation allows conventional pressure sensing technology to obtain improved unsteady pressure measurements. Pressure distortion caused by frictional attenuation and pneumatic resonance within the sensing system makes obtaining unsteady pressure measurements by conventional sensors difficult. Most distortion occurs within the pneumatic tubing which transmits pressure impulses from the aircraft's surface to the measurement transducer. To avoid pneumatic distortion, experiment designers mount the pressure sensor at the surface of the aircraft, (called in-situ mounting). In-situ transducers cannot always fit in the available space and sometimes pneumatic tubing must be run from the aircraft's surface to the pressure transducer. A technique to measure unsteady pressure data using conventional pressure sensing technology was developed. A pneumatic distortion model is reduced to a low-order, state-variable model retaining most of the dynamic characteristics of the full model. The reduced-order model is coupled with results from minimum variance estimation theory to develop an algorithm to compensate for the effects of pneumatic distortion. Both postflight and real-time algorithms are developed and evaluated using simulated and flight data.

  10. Pneumatization degree of the anterior clinoid process: a new classification.

    PubMed

    Abuzayed, Bashar; Tanriover, Necmettin; Biceroglu, Huseyin; Yuksel, Odhan; Tanriover, Ozlem; Albayram, Sait; Akar, Ziya

    2010-07-01

    The objective of this study is to determine the incidence and degree of anterior clinoid process pneumatization, in addition highlighting to their clinical significance. Multidetector-row CT scans of the skull base were reviewed in 648 subjects between 2007 and 2008. The presence of pneumatized anterior clinoid process and its degree were studied and documented. These data were statistically analyzed. Pneumatization of the ACP was found in 62 of 648 patients (9.6%) including 32 (51.6%) men and 30 (48.4%) women. The age of these patients ranged from 21 to 82 years (mean, 41 +/- 15.7 years). Pneumatization of the ACP occurred only on the left side in 14 cases (22.6%), only on the right side in 11 cases (17.7%), and bilaterally in 37 patients (59.7%). ACP pneumatization Type I, in which less than 50% of the ACP is pneumatized, was found in 47 of 124 sides (38%), Type II, in which more than 50% but not totally pneumatized ACP, was found in 28 of 124 sides (22.6%), and Type III, in which the ACP is totally pneumatized, was found in 22 of 124 sides (17.7%). The incidence of Type I in the general population was 6.6%, Type II was 3.5%, and Type III was 2.5%. Radiologically recognizing the degree of ACP pneumatization is important in decreasing the incidence of surgical complications during anterior clinoidectomy. Proper intraoperative management can be undertaken with special attention to the new classification.

  11. Autoantibody Production in Rabbits

    PubMed Central

    Asherson, G. L.; Rose, M. Elaine

    1963-01-01

    The finding that the serum of apparently healthy rabbits fixed complement with rabbit liver and kidney has been confirmed. Experimental infection of rabbits with Eimeria stiedae, the cause of hepatic coccidiosis, led to a rise in the titre of serum complement-fixing factors. The rise was statistically significant 14, 21 and 28 days after infection. The factors were regarded as antibodies because they behaved as macroglobulins on diethylaminoethyl—cellulose chromatography and sucrose gradient centrifugation, and as autoantibodies because they fixed complement with the kidney of the rabbits in which they occurred. The antibody reacted with widely distributed antigen(s) with high activity in brain and low activity in skeletal muscle. The possibility that coccidial infection may be responsible for the natural autoantibody of rabbits is discussed. PMID:13965167

  12. Optimizing pneumatic conveying of biomass materials

    NASA Astrophysics Data System (ADS)

    DiCianni, Matthew Edward Michael

    2011-12-01

    Biomass is a readily available but underutilized energy resource. One of the main challenges is the inability of biomass feed stocks like corn stover or wood chips to flow freely without intermittent jamming. This research integrated an automated pneumatic conveying system to efficiently transport biomass into a biomass reactor. Material was held in a storage container until an end effector attached to a 3-axis controller engaged the material to flow through pneumatic vacuum in the carrier fluid of air. The material was disengaged from the carrier fluid through centripetal forces induced by a cyclone separator. As the air was pulled out of the cyclone, the biomass drops out the bottom due to gravitational forces and fell into a secondary storage hopper. The second storage container was for testing purposes only, where the actual apparatus would use a vertically oriented lock hopper to feed material into the biomass reactor. In the experimental test apparatus, sensors measured the storage hopper weight (mass-flow rate), pressure drop from the blower, and input power consumption of the motor. Parameters that were adjusted during testing include pipe diameter, material type, and motor speed. Testing indicated that decreasing the motor speed below its maximum still allows for conveyance of the material without blockage forming in the piping. The data shows that the power consumption of the system can be reduced based on the size and weight of the material introduced to the conveying pipe. Also, conveying certain materials proved to be problematic with particular duct diameters. Ultimately, an optimal duct diameter that can perform efficiently for a broad range of materials was chosen for the given system. Through these improvements, the energy return on investment will be improved for biomass feed stocks, which is taking a step in the right direction to secure the nation's energy independence.

  13. Spot-Welding Gun With Adjustable Pneumatic Spring

    NASA Technical Reports Server (NTRS)

    Burley, Richard K.

    1990-01-01

    Proposed spot-welding gun equipped with pneumatic spring, which could be bellows or piston and cylinder, exerts force independent of position along stroke. Applies accurate controlled force to joint welded, without precise positioning at critical position within stroke.

  14. TOPICAL REVIEW: Pneumatic and hydraulic microactuators: a review

    NASA Astrophysics Data System (ADS)

    De Volder, Michaël; Reynaerts, Dominiek

    2010-04-01

    The development of MEMS actuators is rapidly evolving and continuously new progress in terms of efficiency, power and force output is reported. Pneumatic and hydraulic are an interesting class of microactuators that are easily overlooked. Despite the 20 years of research, and hundreds of publications on this topic, these actuators are only popular in microfluidic systems. In other MEMS applications, pneumatic and hydraulic actuators are rare in comparison with electrostatic, thermal or piezo-electric actuators. However, several studies have shown that hydraulic and pneumatic actuators deliver among the highest force and power densities at microscale. It is believed that this asset is particularly important in modern industrial and medical microsystems, and therefore, pneumatic and hydraulic actuators could start playing an increasingly important role. This paper shows an in-depth overview of the developments in this field ranging from the classic inflatable membrane actuators to more complex piston-cylinder and drag-based microdevices.

  15. PNEUMATICALLY CLEANING TOP HALF OF LARGE MOLD IN BOX FLOOR ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    PNEUMATICALLY CLEANING TOP HALF OF LARGE MOLD IN BOX FLOOR AREA TO REMOVE ANY EXCESS OR LOOSE SAND. - Stockham Pipe & Fittings Company, Ductile Iron Foundry, 4000 Tenth Avenue North, Birmingham, Jefferson County, AL

  16. 23. CORE WORKER OPERATING A COREBLOWER THAT PNEUMATICALLY FILLED CORE ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    23. CORE WORKER OPERATING A CORE-BLOWER THAT PNEUMATICALLY FILLED CORE BOXES WITH RESIGN IMPREGNATED SAND AND CREATED A CORE THAT THEN REQUIRED BAKING, CA. 1950. - Stockham Pipe & Fittings Company, 4000 Tenth Avenue North, Birmingham, Jefferson County, AL

  17. Microfluidic pressure amplifier circuits and electrostatic gates for pneumatic microsystems

    SciTech Connect

    Tice, Joshua D.; Bassett, Thomas A.; Desai, Amit V.; Apblett, Christopher A.; Kenis, Paul J. A.

    2016-09-20

    An electrostatic actuator is provide that can include a fluidic line, a first electrode, and a second electrode such that a gate chamber portion of the fluidic line is sandwiched between the first electrode and the second electrode. The electrostatic actuator can also include a pressure-balancing channel in fluid communication with the gate chamber portion where the first electrode is sandwiched between the pressure-balancing channel and the gate chamber portion. A pneumatic valve system is provided which includes an electrostatic gate and a fluidic channel fluidly separate from a fluidic control line. A pneumatic valve portion of the fluidic control line can be positioned relative to a portion of the fluidic channel such that expansion of the pneumatic valve portion restricts fluid flow through the fluidic channel. Methods of using an electrostatic actuator and a pneumatic valve system are also provided.

  18. Detail, north end of console and pneumatic tube message port, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Detail, north end of console and pneumatic tube message port, also showing mirror to reflect view of communications switchboard - March Air Force Base, Strategic Air Command, Combat Operations Center, 5220 Riverside Drive, Moreno Valley, Riverside County, CA

  19. Inline evenflow material distributor for pneumatic material feed systems

    DOEpatents

    Thiry, Michael J.

    2007-02-20

    An apparatus for reducing clogs in a pneumatic material feed line, such as employed in abrasive waterjet machining systems, by providing an evenflow feed of material therethrough. The apparatus preferably includes a hollow housing defining a housing volume and having an inlet capable of connecting to an upstream portion of the pneumatic material feed line, an outlet capable of connecting to a downstream portion of the pneumatic material feed line, and an air vent located between the inlet and outlet for venting excess air pressure out from the housing volume. A diverter, i.e. an impingement object, is located at the inlet and in a path of incoming material from the upstream portion of the pneumatic material feed line, to break up clumps of ambient moisture-ridden material impinging on the diverter. And one or more filter screens is also preferably located in the housing volume to further break up clumps and provide filtering.

  20. Analytical Solution to the Pneumatic Transient Rod System at ACRR

    SciTech Connect

    Fehr, Brandon Michael

    2016-01-08

    The ACRR pulse is pneumatically driven by nitrogen in a system of pipes, valves and hoses up to the connection of the pneumatic system and mechanical linkages of the transient rod (TR). The main components of the TR pneumatic system are the regulator, accumulator, solenoid valve and piston-cylinder assembly. The purpose of this analysis is to analyze the flow of nitrogen through the TR pneumatic system in order to develop a motion profile of the piston during the pulse and be able to predict the pressure distributions inside both the cylinder and accumulators. The predicted pressure distributions will be validated against pressure transducer data, while the motion profile will be compared to proximity switch data. By predicting the motion of the piston, pulse timing will be determined and provided to the engineers/operators for verification. The motion profile will provide an acceleration distribution to be used in Razorback to more accurately predict reactivity insertion into the system.

  1. Effects of low-power laser irradiation on the mitosis rate of the corneal epithelium

    NASA Astrophysics Data System (ADS)

    Chen, Varda; Landshman, Nahum; Belkin, Michael

    1995-05-01

    The effect of repeated low power He-Ne laser on rabbit's corneal epithelium was studied after 3 daily sessions. Under certain irradiation parameters, low power He-Ne laser irradiation was found to change the mitotic rate in the basal layer of intact corneal epithelium. Three daily irradiations for 3 or 10 minutes increased the mitotic index while 30 minutes irradiations decreased it.

  2. Pneumatic Regolith Transfer Systems for In Situ Resource Utilization

    NASA Technical Reports Server (NTRS)

    Mueller, R. P.; Townsend, I. I.; Mantovani, J. G.; Zacny, Kris A.; Craft, Jack

    2010-01-01

    This slide presentation reviews the testing of a pneumatic system for transfering regolith, to be used for In Situ Resource Utilization (ISRU). Using both the simulated microgravity of parabolic flight and ground testing, the tests demonstrated that lunar regolith can be conveyed pneumatically into a simulated ISRU oxygen production plant reactor. The ground testing also demonstrated that the regolith can be expelled from the ISRU reactor for disposal or for other resource processing.

  3. Intracranial pressure monitoring system with pneumatic capsule sensor

    NASA Astrophysics Data System (ADS)

    Juniewicz, Henryk M.; Werszko, Miroslaw

    1995-06-01

    In the paper, a computer system for measurement, visualization and analysis of intracranial pressure (ICP), medium arterial pressure and cerebral perfusion pressure in one, two, three or four patients simultaneously has been presented. A structure of pneumatic compensatory sensor for intracranial pressure, and a stand for static properties of the sensors testing has been discussed. Conclusions resulting from the period of using the monitoring system with ICP pneumatic sensors have been formulated.

  4. Development of pneumatic actuator with low-wave reflection characteristics

    NASA Astrophysics Data System (ADS)

    Chang, H.; Tsung, T. T.; Jwo, C. S.; Chiang, J. C.

    2010-08-01

    This study aims at the development of a less reflective electromagnetic pneumatic actuator often used in the anechoic chamber. Because a pneumatic actuator on the market is not appropriate for use in such a chamber and a metallic one has high dielectric constant which generates reflective electromagnetic waves to influence test parameters in the chamber. The newly developed pneumatic actuator is made from low dielectric constant plastics with less reflective of electromagnetic. A turbine-type air motor is used to develop the pneumatic actuator and a employ Prony tester is used to run the brake horsepower test for the performance test of pneumatic actuator. Test results indicate that the pneumatic actuator in the minimal starting flow is 17 l/min, and it generates a brake horsepower of 48 mW; in the maximum flow is 26 l/min, it generates a brake horsepower of 108 mW. Therefore, it works with a torque between 0.24 N-m and 0.55 N-m, and such a torque will be sufficient to drive the target button.

  5. A New Type of Motor: Pneumatic Step Motor

    PubMed Central

    Stoianovici, Dan; Patriciu, Alexandru; Petrisor, Doru; Mazilu, Dumitru; Kavoussi, Louis

    2011-01-01

    This paper presents a new type of pneumatic motor, a pneumatic step motor (PneuStep). Directional rotary motion of discrete displacement is achieved by sequentially pressurizing the three ports of the motor. Pulsed pressure waves are generated by a remote pneumatic distributor. The motor assembly includes a motor, gearhead, and incremental position encoder in a compact, central bore construction. A special electronic driver is used to control the new motor with electric stepper indexers and standard motion control cards. The motor accepts open-loop step operation as well as closed-loop control with position feedback from the enclosed sensor. A special control feature is implemented to adapt classic control algorithms to the new motor, and is experimentally validated. The speed performance of the motor degrades with the length of the pneumatic hoses between the distributor and motor. Experimental results are presented to reveal this behavior and set the expectation level. Nevertheless, the stepper achieves easily controllable precise motion unlike other pneumatic motors. The motor was designed to be compatible with magnetic resonance medical imaging equipment, for actuating an image-guided intervention robot, for medical applications. For this reason, the motors were entirely made of nonmagnetic and dielectric materials such as plastics, ceramics, and rubbers. Encoding was performed with fiber optics, so that the motors are electricity free, exclusively using pressure and light. PneuStep is readily applicable to other pneumatic or hydraulic precision-motion applications. PMID:21528106

  6. Hepatitis E Virus in Farmed Rabbits, Wild Rabbits and Petting Farm Rabbits in the Netherlands.

    PubMed

    Burt, Sara A; Veltman, Jorg; Hakze-van der Honing, Renate; Schmitt, Heike; van der Poel, Wim H M

    2016-09-01

    Rabbits have been suggested as a zoonotic source of Hepatitis E virus. Phylogenetic analysis of HEV isolates from farmed, wild and pet rabbits in the Netherlands (23, 0, and 60 % respectively) showed them to be grouped amongst published rabbit HEV sequences and distinct from most human isolates. Dutch rabbits are unlikely to be a zoonotic source.

  7. SERUM SICKNESS IN RABBITS

    PubMed Central

    Fleisher, Mover S.; Jones, Lloyd

    1931-01-01

    1. The injection of a single large dose of normal horse serum into rabbits results in the appearance 3 to 8 days later of erythematous and edematous reactions on the ears in 68.9 per cent of the animals. 2. The injections may be given by any of several routes and reactions appear when the site of injection is definitely distant from the ears. 3. Injections of various antisera into rabbits cause the appearance of similar reactions. 4. These reactions can be considered as manifestations of serum sickness in rabbits. PMID:19869943

  8. Rabbit orthopedic surgery.

    PubMed

    Rich, Gregory A

    2002-01-01

    Orthopedic surgery in rabbits poses several unique parameters for the veterinary surgeon. It is imperative for the veterinarian to be knowledgeable about the anatomic features of the surgical repair site and to become familiar with a rabbit's pain and discomfort often associated with orthopedic injuries. Handling the perioperative and postoperative pain and potential GI disturbances are crucial for a successful outcome of the surgical case. This article is designed to help the veterinary surgeon prepare for the orthopedic surgical procedure and the peripheral physiologic needs of the rabbit from presentation through recovery.

  9. Design of flat pneumatic artificial muscles

    NASA Astrophysics Data System (ADS)

    Wirekoh, Jackson; Park, Yong-Lae

    2017-03-01

    Pneumatic artificial muscles (PAMs) have gained wide use in the field of robotics due to their ability to generate linear forces and motions with a simple mechanism, while remaining lightweight and compact. However, PAMs are limited by their traditional cylindrical form factors, which must increase radially to improve contraction force generation. Additionally, this form factor results in overly complicated fabrication processes when embedded fibers and sensor elements are required to provide efficient actuation and control of the PAMs while minimizing the bulkiness of the overall robotic system. In order to overcome these limitations, a flat two-dimensional PAM capable of being fabricated using a simple layered manufacturing process was created. Furthermore, a theoretical model was developed using Von Karman’s formulation for large deformations and the energy methods. Experimental characterizations of two different types of PAMs, a single-cell unit and a multi-cell unit, were performed to measure the maximum contraction lengths and forces at input pressures ranging from 0 to 150 kPa. Experimental data were then used to verify the fidelity of the theoretical model.

  10. Experimental investigations in hamsters and rabbits with DNA extracted from human uterine tumors.

    PubMed

    Nastac, E; Athanasiu, P; Predescu, E; Stoian, M; Hozoc, M; Perju, A

    1980-01-01

    Experimental inoculation of a DNA preparation extracted from a fragment of non-irradiated human uterine cervix carcinoma was followed by the appearance of neoplasia in four hamsters and of lymphosarcoma in one rabbit. Similar DNA preparations obtained from three cases of irradiated human uterine cervix carcinoma and from a human uterine fibroma proved to have no biological activity.

  11. Pneumatic distortion compensation for aircraft surface pressure sensing devices

    NASA Technical Reports Server (NTRS)

    Whitmore, Stephen A.; Leondes, Cornelius T.

    1991-01-01

    In this paper a technique of compensating for pneumatic distortion in aircraft surface pressure sensing devices is developed. The compensation allows conventional pressure sensing technology to obtain improved unsteady pressure measurements. Pressure distortion caused by frictional attenuation and pneumatic resonance within the sensing system makes obtaining unsteady pressure measurements by conventional sensors difficult. Typically, most of the distortion occurs within the pneumatic tubing used to transmit pressure impulses from the surface of the aircraft to the measurement transducer. This paper develops a second-order distortion model that accurately describes the behavior of the primary wave harmonic of the pneumatic tubing. The model is expressed in state-variable form and is coupled with standard results from minimum-variance estimation theory to develop an algorithm to compensate for the effects of pneumatic distortion. Both postflight and real-time algorithms are developed and evaluated using simulated and flight data. Covariance selection and filter-tuning examples are presented. Results presented verify that, given appropriate covariance magnitudes, the algorithms accurately reconstruct surface pressure values from remotely sensed pressure measurements.

  12. Mechanical implications of pneumatic neck vertebrae in sauropod dinosaurs.

    PubMed

    Schwarz-Wings, Daniela; Meyer, Christian A; Frey, Eberhard; Manz-Steiner, Hans-Rudolf; Schumacher, Ralf

    2010-01-07

    The pre-sacral vertebrae of most sauropod dinosaurs were surrounded by interconnected, air-filled diverticula, penetrating into the bones and creating an intricate internal cavity system within the vertebrae. Computational finite-element models of two sauropod cervical vertebrae now demonstrate the mechanical reason for vertebral pneumaticity. The analyses show that the structure of the cervical vertebrae leads to an even distribution of all occurring stress fields along the vertebrae, concentrated mainly on their external surface and the vertebral laminae. The regions between vertebral laminae and the interior part of the vertebral body including thin bony struts and septa are mostly unloaded and pneumatic structures are positioned in these regions of minimal stress. The morphology of sauropod cervical vertebrae was influenced by strongly segmented axial neck muscles, which require only small attachment areas on each vertebra, and pneumatic epithelia that are able to resorb bone that is not mechanically loaded. The interaction of these soft tissues with the bony tissue of the vertebrae produced lightweight, air-filled vertebrae in which most stresses were borne by the external cortical bone. Cervical pneumaticity was therefore an important prerequisite for neck enlargement in sauropods. Thus, we expect that vertebral pneumaticity in other parts of the body to have a similar role in enabling gigantism.

  13. Mechanical implications of pneumatic neck vertebrae in sauropod dinosaurs

    PubMed Central

    Schwarz-Wings, Daniela; Meyer, Christian A.; Frey, Eberhard; Manz-Steiner, Hans-Rudolf; Schumacher, Ralf

    2010-01-01

    The pre-sacral vertebrae of most sauropod dinosaurs were surrounded by interconnected, air-filled diverticula, penetrating into the bones and creating an intricate internal cavity system within the vertebrae. Computational finite-element models of two sauropod cervical vertebrae now demonstrate the mechanical reason for vertebral pneumaticity. The analyses show that the structure of the cervical vertebrae leads to an even distribution of all occurring stress fields along the vertebrae, concentrated mainly on their external surface and the vertebral laminae. The regions between vertebral laminae and the interior part of the vertebral body including thin bony struts and septa are mostly unloaded and pneumatic structures are positioned in these regions of minimal stress. The morphology of sauropod cervical vertebrae was influenced by strongly segmented axial neck muscles, which require only small attachment areas on each vertebra, and pneumatic epithelia that are able to resorb bone that is not mechanically loaded. The interaction of these soft tissues with the bony tissue of the vertebrae produced lightweight, air-filled vertebrae in which most stresses were borne by the external cortical bone. Cervical pneumaticity was therefore an important prerequisite for neck enlargement in sauropods. Thus, we expect that vertebral pneumaticity in other parts of the body to have a similar role in enabling gigantism. PMID:19801376

  14. A Pneumatic Actuated Microfluidic Beads-Trapping Device

    SciTech Connect

    Shao, Guocheng; Cai, Ziliang; Wang, Jun; Wang, Wanjun; Lin, Yuehe

    2011-08-20

    The development of a polydimethylsiloxane (PDMS) microfluidic microbeads trapping device is reported in this paper. Besides fluid channels, the proposed device includes a pneumatic control chamber and a beads-trapping chamber with a filter array structure. The pneumatic flow control chamber and the beads-trapping chamber are vertically stacked and separated by a thin membrane. By adjusting the pressure in the pneumatic control chamber, the membrane can either be pushed against the filter array to set the device in trapping mode or be released to set the device in releasing mode. In this paper, a computational fluid dynamics simulation was conducted to optimize the geometry design of the filter array structure; the device fabrication was also carried out. The prototype device was tested and the preliminary experimental results showed that it can be used as a beads-trapping unit for various biochemistry and analytical chemistry applications, especially for flow injection analysis systems.

  15. An ankle-foot orthosis powered by artificial pneumatic muscles.

    PubMed

    Ferris, Daniel P; Czerniecki, Joseph M; Hannaford, Blake

    2005-05-01

    We developed a pneumatically powered orthosis for the human ankle joint. The orthosis consisted of a carbon fiber shell, hinge joint, and two artificial pneumatic muscles. One artificial pneumatic muscle provided plantar flexion torque and the second one provided dorsiflexion torque. Computer software adjusted air pressure in each artificial muscle independently so that artificial muscle force was proportional to rectified low-pass-filtered electromyography (EMG) amplitude (i.e., proportional myoelectric control). Tibialis anterior EMG activated the artificial dorsiflexor and soleus EMG activated the artificial plantar flexor. We collected joint kinematic and artificial muscle force data as one healthy participant walked on a treadmill with the orthosis. Peak plantar flexor torque provided by the orthosis was 70 Nm, and peak dorsiflexor torque provided by the orthosis was 38 Nm. The orthosis could be useful for basic science studies on human locomotion or possibly for gait rehabilitation after neurological injury.

  16. An Ankle-Foot Orthosis Powered by Artificial Pneumatic Muscles

    PubMed Central

    Ferris, Daniel P.; Czerniecki, Joseph M.; Hannaford, Blake

    2005-01-01

    We developed a pneumatically powered orthosis for the human ankle joint. The orthosis consisted of a carbon fiber shell, hinge joint, and two artificial pneumatic muscles. One artificial pneumatic muscle provided plantar flexion torque and the second one provided dorsiflexion torque. Computer software adjusted air pressure in each artificial muscle independently so that artificial muscle force was proportional to rectified low-pass-filtered electromyography (EMG) amplitude (i.e., proportional myoelectric control). Tibialis anterior EMG activated the artificial dorsiflexor and soleus EMG activated the artificial plantar flexor. We collected joint kinematic and artificial muscle force data as one healthy participant walked on a treadmill with the orthosis. Peak plantar flexor torque provided by the orthosis was 70 Nm, and peak dorsiflexor torque provided by the orthosis was 38 Nm. The orthosis could be useful for basic science studies on human locomotion or possibly for gait rehabilitation after neurological injury. PMID:16082019

  17. 46 CFR 54.10-15 - Pneumatic test (modifies UG-100).

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... first opportunity following the pneumatic test. The tank supports and saddles, connecting piping, and... 46 Shipping 2 2010-10-01 2010-10-01 false Pneumatic test (modifies UG-100). 54.10-15 Section 54.10... VESSELS Inspection, Reports, and Stamping § 54.10-15 Pneumatic test (modifies UG-100). (a)...

  18. 46 CFR 128.240 - Hydraulic or pneumatic power and control-materials and pressure design.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 4 2012-10-01 2012-10-01 false Hydraulic or pneumatic power and control-materials and... Hydraulic or pneumatic power and control—materials and pressure design. (a) Each standard piping component (such as pipe runs, fittings, flanges, and standard valves) for hydraulic or pneumatic power and...

  19. 46 CFR 128.240 - Hydraulic or pneumatic power and control-materials and pressure design.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Hydraulic or pneumatic power and control-materials and... Hydraulic or pneumatic power and control—materials and pressure design. (a) Each standard piping component (such as pipe runs, fittings, flanges, and standard valves) for hydraulic or pneumatic power and...

  20. 46 CFR 128.240 - Hydraulic or pneumatic power and control-materials and pressure design.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 4 2014-10-01 2014-10-01 false Hydraulic or pneumatic power and control-materials and... Hydraulic or pneumatic power and control—materials and pressure design. (a) Each standard piping component (such as pipe runs, fittings, flanges, and standard valves) for hydraulic or pneumatic power and...

  1. 46 CFR 128.240 - Hydraulic or pneumatic power and control-materials and pressure design.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 4 2013-10-01 2013-10-01 false Hydraulic or pneumatic power and control-materials and... Hydraulic or pneumatic power and control—materials and pressure design. (a) Each standard piping component (such as pipe runs, fittings, flanges, and standard valves) for hydraulic or pneumatic power and...

  2. 14 CFR 23.1416 - Pneumatic de-icer boot system.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 14 Aeronautics and Space 1 2014-01-01 2014-01-01 false Pneumatic de-icer boot system. 23.1416... Safety Equipment § 23.1416 Pneumatic de-icer boot system. If certification with ice protection provisions is desired and a pneumatic de-icer boot system is installed— (a) The system must meet...

  3. 14 CFR 23.1416 - Pneumatic de-icer boot system.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Pneumatic de-icer boot system. 23.1416... Safety Equipment § 23.1416 Pneumatic de-icer boot system. If certification with ice protection provisions is desired and a pneumatic de-icer boot system is installed— (a) The system must meet...

  4. 14 CFR 23.1416 - Pneumatic de-icer boot system.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 14 Aeronautics and Space 1 2012-01-01 2012-01-01 false Pneumatic de-icer boot system. 23.1416... Safety Equipment § 23.1416 Pneumatic de-icer boot system. If certification with ice protection provisions is desired and a pneumatic de-icer boot system is installed— (a) The system must meet...

  5. 14 CFR 23.1416 - Pneumatic de-icer boot system.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 14 Aeronautics and Space 1 2013-01-01 2013-01-01 false Pneumatic de-icer boot system. 23.1416... Safety Equipment § 23.1416 Pneumatic de-icer boot system. If certification with ice protection provisions is desired and a pneumatic de-icer boot system is installed— (a) The system must meet...

  6. 78 FR 3843 - Federal Motor Vehicle Safety Standards; New Pneumatic and Certain Specialty Tires

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-01-17

    ... Pneumatic Tyres For Passenger-Use Motor Vehicles, Annex, 1-2-5. We believed that existing 60-psi T-type... Standards; New Pneumatic and Certain Specialty Tires AGENCY: National Highway Traffic Safety Administration... Motor Vehicle Safety Standard (FMVSS) No. 109, New pneumatic and certain specialty tires, to change...

  7. Evaluation of a pneumatic Martian soil sampler concept

    NASA Technical Reports Server (NTRS)

    Schaefer, John L.; Neathery, James K.; Stencel, John M.

    1994-01-01

    The pneumatic soil sampler concept was successfully demonstrated by penetrating a Martian simulant soil to a depth of 2 meters. Working gas pressure, composition, and pulsing were evaluated with the objective of minimizing gas usage. Also, the probe penetration force was investigated with the objective of minimizing probe weight. Gas and probe penetration force, while not yet optimized, are within the range which make the soil sampler concept feasible. While the tests described in this report did not answer all the questions and address all the variables associated with pneumatic soil sampling, valuable data experience and knowledge were gained which can be used to further develop the concept.

  8. Overall life cycle comprehensive assessment of pneumatic and electric actuator

    NASA Astrophysics Data System (ADS)

    Zhang, Yeming; Cai, Maolin

    2014-05-01

    Pneumatic actuators and electric actuators have almost been applied to all manufacturing industries. The two kinds of actuators can replace each other in most fields, such as the point to point transmission occasion and some rotating occasions. However, there are very few research results about the advantages and disadvantages of two kinds of actuators under the same working conditions so far. In this paper, a novel comprehensive assessment method, named as overall life cycle comprehensive assessment (OLCCA), is proposed for comparison and assessment of pneumatic and electric actuators. OLCCA contains mechanical properties evaluation (MPE), life cycle cost analysis based on users (LCCABOU) and life cycle environmental impact analysis (LCEIA) algorithm in order to solve three difficult problems: mechanical properties assessment, cost analysis and environmental impact assessment about actuators. The mechanical properties evaluation of actuators is a multi-objective optimization problem. The fuzzy data quantification and information entropy methods are combined to establish MPE algorithm of actuators. Two kinds of pneumatic actuators and electric actuators with similar bearing capacity and similar work stroke were taken for example to verify the correctness of MPE algorithm. The case study of MPE algorithm for actuators verified its correctness. LCCABOU for actuators is also set up. Considering cost complex structure of pneumatic actuators, public device cost even method (PDCEM) is firstly presented to solve cost division of public devices such as compressors, aftercooler, receivers, etc. LCCABOU method is also effective and verified by the three groups of pneumatic actuators and electric actuators. Finally, LCEIA model of actuators is established for the environmental impact assessment of actuators. LCEIA data collection method and model establishment procedure for actuators are also put forward. With Simapro 7, LCEIA comparison results of six actuators can be

  9. Compensating for pneumatic distortion in pressure sensing devices

    NASA Technical Reports Server (NTRS)

    Whitmore, Stephen A.; Leondes, Cornelius T.

    1990-01-01

    A general numerical technique for obtaining unsteady pressure measurements using conventional pressure sensing technology has been developed. A pneumatic distortion model, based on the Navier-Stokes equations of momentum and continuity, was reduced to a low-order, state-variable model retaining most of the dynamic characteristics of the full model. The reduced-order model is coupled with results from minimum variance estimation theory to develop an algorithm to compensate the effects of pneumatic distortion. Both postflight and real-time algorithms were developed and evaluated using simulated and flight data.

  10. A pneumatic vibrotactile stimulation device for fMRI.

    PubMed

    Briggs, Richard W; Dy-Liacco, Iona; Malcolm, Matthew P; Lee, Hyunsook; Peck, Kyung K; Gopinath, Kaundinya S; Himes, Nathan C; Soltysik, David A; Browne, Paul; Tran-Son-Tay, Roger

    2004-03-01

    Mapping the functional response of the somatosensory cortex is useful both for characterizing normal brain activity and for determining the functional integrity of damaged cortex compromised by stroke or other neurological insults. A variety of stimulators have been used to produce somatosensory cortex activation in functional brain imaging, including brushes and swabs operated manually, pneumatically and mechanically powered mechanical vibrators, air puffs, and vibrating ceramic piezoelectric wafers and benders. A closed-system, pneumatically driven rubber diaphragm is reported that overcomes many of the limitations of existing vibrotactile devices and produces robust sensory cortex activation in an fMRI experiment.

  11. Irradiation effect of polarization direction and intensity of semiconductor laser on injured peripheral nerve

    NASA Astrophysics Data System (ADS)

    Guo-Xin, Xiong; Lei-lei, Xiong

    2016-08-01

    To investigate the irradiation effect of polarization direction and the intensity of a semiconductor laser on the injured peripheral nerve in rabbits, the model of the injured common peroneal nerve was established, the L5,6 spinal segments of the rabbits were irradiated, a uniform rotating polarizer was placed at the laser output which made the polarization direction and intensity of the output laser change according to the 80 Hz cosine law. The experimental results show that irradiating the spinal segment of injured nerves in rabbits with this changeable semiconductor laser can significantly promote the regeneration of injured peripheral nerves and the function recovery.

  12. Intermittent pneumatic soft tissue compression: Changes in periosteal and medullary canal blood flow.

    PubMed

    Park, Sang-Hyun; Silva, Mauricio

    2008-04-01

    We previously demonstrated that the use of intermittent pneumatic soft tissue compression (IPC) treatment enhanced fracture healing in an animal model, but the exact mechanism remained unknown. The purpose of this study was to determine the local and remote effects of IPC treatment on blood flow within the medullary canal and outside the periosteum of mid-tibial diaphysis. Blood flow was measured with a Laser Doppler blood flow meter in the lower limbs of 21 rabbits. Laser probes were inserted at three different sites of the mid-diaphysis on the right tibia: in the medullary canal (n = 21), outside the periosteum on the lateral side (n = 11), and outside the periosteum on the medial side (n = 10). IPC was applied for 30 min through cuffs that were placed around the feet and the lower part of the calf. While applying IPC to the left leg, no changes in blood flow occurred on the right leg (remote changes). However, while applying IPC to the right leg, significant localized changes were found on the right leg, including 47 and 89% increases in total amount of blood flow outside the lateral and medial periosteum, respectively. Although an altered blood flow pattern was observed in the medullary canal, no significant change in total amount of blood flow was observed at this level. In summary, the present study demonstrated that the use of IPC in an intact bone model results in a significant local increase in total blood flow, with minimal measurable effects on the contralateral limb.

  13. Design considerations for single-stage and two-stage pneumatic pellet injectors

    SciTech Connect

    Gouge, M.J.; Combs, S.K.; Fisher, P.W.; Milora, S.L.

    1988-09-01

    Performance of single-stage pneumatic pellet injectors is compared with several models for one-dimensional, compressible fluid flow. Agreement is quite good for models that reflect actual breech chamber geometry and incorporate nonideal effects such as gas friction. Several methods of improving the performance of single-stage pneumatic pellet injectors in the near term are outlined. The design and performance of two-stage pneumatic pellet injectors are discussed, and initial data from the two-stage pneumatic pellet injector test facility at Oak Ridge National Laboratory are presented. Finally, a concept for a repeating two-stage pneumatic pellet injector is described. 27 refs., 8 figs., 3 tabs.

  14. The Cutaneous Rabbit Revisited

    ERIC Educational Resources Information Center

    Flach, Rudiger; Haggard, Patrick

    2006-01-01

    In the cutaneous rabbit effect (CRE), a tactile event (so-called attractee tap) is mislocalized toward an adjacent attractor tap. The effect depends on the time interval between the taps. The authors delivered sequences of taps to the forearm and asked participants to report the location of one of the taps. The authors replicated the original CRE…

  15. Autoantibody Production in Rabbits

    PubMed Central

    Asherson, G. L.; Dumonde, D. C.

    1963-01-01

    The sera of rabbits injected with rat liver, kidney, heart, muscle, spleen and brain in Freund's complete adjuvant fixed complement with rabbit tissue. This complement-fixing activity was attributed to autoantibodies which were able to fix complement in vitro with the tissue of the rabbit in which they occurred. Absorption, gel diffusion and antibody and antigen titrations indicated that some of the anti-liver, anti-kidney, anti-heart, anti-muscle and anti-brain sera contained organ-specific autoantibody. The sera also contained autoantibody reacting with widely distributed antigen(s), which was relatively labile at 65°. The anti-kidney and anti-brain sera reacted with distinct antigens which were extracted from rabbit kidney and brain with a mixture of chloroform and methanol. The natural autoantibody of Kidd and Friedewald was usually labile at 65° and behaved like a macroglobulin on sucrose gradient centrifugation. Sera taken 1 week after immunization with rat tissue contained heat-labile macroglobulin antibody. However, sera taken 1 month after immunization also contained small molecular weight antibody which was stable at 65°. PMID:13965166

  16. Low-energy pneumatic control of forebody vortices

    NASA Technical Reports Server (NTRS)

    Roos, Frederick W.

    1994-01-01

    This research will be exploring the prospect of employing bluntness, known to suppress the tendency toward asymmetry on slender forebodies, jointly with pneumatic manipulation as a system of forebody asymmetry control. The influences of jet location and direction, blowing rate, relative noise bluntness, angle of attack, and state of flow separation feeding the vortices (laminar vs. turbulent) will be evaluated.

  17. Control and monitoring system for clinically employed pneumatic blood pumps.

    PubMed

    Normann, N A; Henrichsen, D W; Cooper, T G; King, R E; Noon, G P; DeBakey, M E

    1977-01-01

    Instantaneous position of the flexing member in pneumatic blood pumps is monitored on-line by measuring the electrical capacitance across the gas space within the pump. Monitor output is utilized in closed-loop pump control and for automatic pump shutdown in response to operational abnormalities. Thus, safety and efficacy are enhanced through operational optimization, automatic safety features, and facilitated evaluation.

  18. Pneumatic Power Drive Wheel and related assembly for Turntable, with ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Pneumatic Power Drive Wheel and related assembly for Turntable, with scale. Not in use August 1994. Turntable rotated with engine and tender on balance by two persons, one on either side at ground level - East Broad Top Railroad & Coal Company, Roundhouse, State Route 994, West of U.S. Route 522, Rockhill Furnace, Huntingdon County, PA

  19. 116. PNEUMATIC SUPPLY PANEL IN CENTER OF VEHICLE MECHANICAL SYSTEMS ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    116. PNEUMATIC SUPPLY PANEL IN CENTER OF VEHICLE MECHANICAL SYSTEMS ROOM (111) OF LSB (BLDG. 770), FACING NORTH. CONTROLS FOR FLOW AND PRESSURE REGULATION OF NITROGEN ON RIGHT SIDE OF PANEL; CONTROLS FOR HELIUM ON LEFT SIDE OF PANEL (AT LEFT EDGE OF PHOTO). - Vandenberg Air Force Base, Space Launch Complex 3, Launch Pad 3 West, Napa & Alden Roads, Lompoc, Santa Barbara County, CA

  20. 117. PNEUMATIC SUPPLY PANEL IN CENTER OF VEHICLE MECHANICAL SYSTEMS ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    117. PNEUMATIC SUPPLY PANEL IN CENTER OF VEHICLE MECHANICAL SYSTEMS ROOM (111), LSB (BLDG. 770), FACING NORTH. CONTROLS FOR FLOW AND PRESSURE REGULATION OF HELIUM ON LEFT SIDE OF PANEL; CONTROLS FOR NITROGEN ON RIGHT SIDE OF PANEL (AT RIGHT EDGE OF PHOTO). - Vandenberg Air Force Base, Space Launch Complex 3, Launch Pad 3 West, Napa & Alden Roads, Lompoc, Santa Barbara County, CA

  1. A Synchronous Mutual Position Control for Vertical Pneumatic Servo System

    NASA Astrophysics Data System (ADS)

    Shibata, Satoru; Yamamoto, Tomonori; Jindai, Mitsuru

    Synchronous control of mutual position for two vertical-type pneumatic servo systems is discussed for practical use in this study. In the proposed control system, a fuzzy controller is used in each pneumatic servo system so that the output of each plant can follow the reference input. A PD controller is introduced to realize the synchronization of both pneumatic servo systems, in which the outputs from this controller are the inputs for revision to both plants. A fuzzy virtual reference generator that can adjust the reference input to both fuzzy controllers adaptively by fuzzy rules is constructed to improve the transient performances of both axes. In addition, the adjustment controller produces a representative value of both cylinder outputs, which is used to synthesize the inputs to the fuzzy virtual reference generator, in order to reach a compromise between the follow-up ability to the reference input in each axis and synchronization of both axes. The applicability of the proposed method is confirmed by experiments using two existent vertical-type pneumatic servo systems.

  2. Characteristics of pneumatically-emplaced dry flue gas desulfurization materials

    SciTech Connect

    Carter, S.D.; Rathbone, R.F.; Graham, U.M.; Robl, T.L.

    1996-12-31

    The University of Kentucky in collaboration with the Department of Energy, Addington, Inc. and Costain Coal is currently developing a commercial concept for the haul back of dry flue gas desulfurization materials (FGDM) into highwall mine adits. The University`s Center for Applied Energy Research (CAER) is investigating emplacement systems for a mine demonstration which is planned for the third quarter of 1996. A laboratory-scale transport system has been built at the CAER to evaluate the potential of pneumatic transport for FGDM emplacement. The system is modeled after shotcreting systems in which water is mixed with cement (FGDM) in a nozzle at the end of the pneumatic pipe. Solids travel approximately 70 ft in the lab-scale system at a rate of up to 6 lb FGDM/minute prior to impingement onto a sample collector. Prehydrated FGDM from a circulating fluidized bed combustor has been successfully emplaced onto vertically positioned sample surfaces without excessive dust liberation. The test program is focussed on determining the pneumatic conditions necessary to maximize the strength of the emplaced FGDM under anticipated mine curing conditions while minimizing dust formation. The mineralogy and strength of a pneumatically created sample are described following curing for 60 days.

  3. 21 CFR 890.3610 - Rigid pneumatic structure orthosis.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Rigid pneumatic structure orthosis. 890.3610 Section 890.3610 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... for medical purposes to provide whole body support by means of a pressurized suit to help...

  4. 21 CFR 890.3610 - Rigid pneumatic structure orthosis.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Rigid pneumatic structure orthosis. 890.3610 Section 890.3610 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... for medical purposes to provide whole body support by means of a pressurized suit to help...

  5. 21 CFR 890.3610 - Rigid pneumatic structure orthosis.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Rigid pneumatic structure orthosis. 890.3610 Section 890.3610 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... for medical purposes to provide whole body support by means of a pressurized suit to help...

  6. 21 CFR 890.3610 - Rigid pneumatic structure orthosis.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Rigid pneumatic structure orthosis. 890.3610 Section 890.3610 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES PHYSICAL MEDICINE DEVICES Physical Medicine Prosthetic Devices § 890.3610...

  7. 21 CFR 890.3610 - Rigid pneumatic structure orthosis.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Rigid pneumatic structure orthosis. 890.3610 Section 890.3610 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES PHYSICAL MEDICINE DEVICES Physical Medicine Prosthetic Devices § 890.3610...

  8. Pneumatic Conveying of Seed Cotton: Minimum Velocity and Pressure Drop

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Electricity is a major cost for cotton gins, representing approximately 20% of variable costs. Fans used for pneumatic conveying consume the majority of electricity at cotton gins. Development of control systems to reduce the air velocity used for conveying seed cotton could significantly decrease e...

  9. Pneumatic Conveying of Seed Cotton: Minimum Velocity and Pressure Drop

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Electricity is major cost for cotton gins, representing approximately 20% of the industry’s variable costs. Fans used for pneumatic conveying consume the majority of electricity at cotton gins. Development of control systems to reduce the air velocity used for conveying seed cotton could significant...

  10. Pneumatic vacuum tube message center, basement room 23, looking southeast ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Pneumatic vacuum tube message center, basement room 23, looking southeast toward doorway and corridor. Note soundproof walls, pedestal flooring, and cable tray suspended from the ceiling - March Air Force Base, Strategic Air Command, Combat Operations Center, 5220 Riverside Drive, Moreno Valley, Riverside County, CA

  11. Adaptive backstepping slide mode control of pneumatic position servo system

    NASA Astrophysics Data System (ADS)

    Ren, Haipeng; Fan, Juntao

    2016-09-01

    With the price decreasing of the pneumatic proportional valve and the high performance micro controller, the simple structure and high tracking performance pneumatic servo system demonstrates more application potential in many fields. However, most existing control methods with high tracking performance need to know the model information and to use pressure sensor. This limits the application of the pneumatic servo system. An adaptive backstepping slide mode control method is proposed for pneumatic position servo system. The proposed method designs adaptive slide mode controller using backstepping design technique. The controller parameter adaptive law is derived from Lyapunov analysis to guarantee the stability of the system. A theorem is testified to show that the state of closed-loop system is uniformly bounded, and the closed-loop system is stable. The advantages of the proposed method include that system dynamic model parameters are not required for the controller design, uncertain parameters bounds are not need, and the bulk and expensive pressure sensor is not needed as well. Experimental results show that the designed controller can achieve better tracking performance, as compared with some existing methods.

  12. The Pneumatic Common: Learning in, with and from the Air

    ERIC Educational Resources Information Center

    Ford, Derek R.

    2015-01-01

    Air is an immersive substance that envelopes us and binds us together, yet it has dominantly been taken for granted and left out of educational and other theorizations. This article develops a conceptualization of the "pneumatic common" in order to address this gap. The specific intervention staged is within recent educational literature…

  13. Autoantibody production in rabbits

    PubMed Central

    Asherson, G. L.; Holborow, E. J.

    1966-01-01

    Rabbits received two injections of dead bacteria in Freund's complete adjuvant. One month later the sera of the rabbits were examined for autoantibodies against gut by indirect immunofluorescence using the rabbit's own stomach, ileum and colon taken at post mortem. Autoantibodies against colon were found in three out of seven rabbits injected with one particular strain of Escherichia coli O64 and in a few animals injected with other E. coli, Salmonella arizona, Proteus mirabilis, Klebsiella pneumoniae and Streptococcus faecalis. The antigen, with which the autoantibodies reacted, behaved like mucus and was detected in the colon and sometimes in the ileum and the stomach. Three patterns of staining were observed: (a) staining of the superficial mucosa of the colon with sparing of the deep glands; (b) staining of scattered groups of glands in the deepest part of the colon with sparing of the superficial glands (this pattern of staining was associated with staining of the superficial mucosa of the body of the stomach); and (c) staining of both the superficial and deep glands of the colon. None of the sera tested reacted with the bronchial or salivary glands. Polysaccharide preparations of the colon, but not the stomach, inhibited the reaction of the autoantibodies with colon in the sera tested. The amount of antigen needed to inhibit the basal staining was much greater than that needed to inhibit the superficial staining. It was concluded that rabbits may produce autoantibodies to colon and in some cases to ileum and stomach following the injection of certain dead bacteria in Freund's complete adjuvant. ImagesFIGS. 1-2FIG. 3FIG. 4FIG. 5FIG. 6 PMID:4956607

  14. Dimensions, septation, and pattern of pneumatization of the sphenoidal sinus.

    PubMed

    Idowu, O E; Balogun, B O; Okoli, C A

    2009-11-01

    The endoscopic endonasal transsphenoidal approach (EEA) to treat sellar, parasellar, and suprasellar tumours continues to gain increased significance. Due to the close proximity of the sphenoid sinus to the carotid artery and the optic canal, it is very important for surgeons to know the anatomical features and variations of the sphenoid sinus as relevant to EEA. A prospective study of the sphenoid sinus morphology was carried out on the cranial tomographic (CT) scan images of 60 Nigerian adult patients. The CTs were reviewed regarding the different anatomical variations of the sphenoid sinus: dimensions, septation, and pattern of pneumatisation. There were 37 males and 23 females. The patients' ages ranged from 18 years to 85 years, with a mean of 47.2 years. There was a main single intersphenoid septum in most patients (95%). The insertion of the septum was usually to the right posteriorly (38%) and in the midline anterior (65%). Although there is usually a main septum, the septa present were multiple in 29 of the sinuses studied. There was no gender difference with respect to the attachment of the main sphenoid sinus septum. The sphenoid anterior, posterior, and transverse dimensions were not significantly dependent on age, but they were longer in males than in females. Sellar pneumatization was present in the majority of the patients (83%), with 4 patients having postsellar pneumatization (6.7%) and 3 patients having presellar pneumatization (5%). There were no cases with conchal pneumatization or lateral pneumatization of the greater wing of the sphenoid. The present study provides anatomical information about the sphenoid sinus dimensions morphology that is essential for avoiding complications in performing an endoscopic sphenoidotomy.

  15. [Comparison of photodynamic effect with respect to human and rabbit erythrocytes].

    PubMed

    Galebskaia, L V; Solovtsova, I L; Solov'eva, M A; Zammoeva, D B; Kuz'menkov, A N

    2011-01-01

    Parameters of photoinduced lysis are studied for human and rabbit erythrocytes (photosensibilizer--Radachlorin, the light source--Shuttle HeNe lazer, lambda = 633 nm). The higher sensitivity to irradiation is revealed for rabbit erythrocytes. Treatment of erythrocytes with trypsin showed the surface proteins in human cells to produce a protective effect. Trypsynization of rabbit erythrocytes produced the opposite action--the rate of photohemolysis increased. Results of the study indicate the differences in sensitivity to the photoinduced lysis of erythrocytes of different species and participation of erythrocytes proteins in the effect of photohemolysis.

  16. Pneumatic fractures in Confined Granular Media

    NASA Astrophysics Data System (ADS)

    Eriksen, Fredrik K.; Toussaint, Renaud; Jørgen Måløy, Knut; Grude Flekkøy, Eirik; Turkaya, Semih

    2016-04-01

    We will present our ongoing study of the patterns formed when air flows into a dry, non-cohesive porous medium confined in a horizontal Hele-Shaw cell. This is an optically transparent system consisting of two glass plates separated by 0.5 to 1 mm, containing a packing of dry 80 micron beads in between. The cell is rectangular and has an air-permeable boundary (blocking beads) at one short edge, while the other three edges are completely sealed. The granular medium is loosely packed against the semi-permeable boundary and fills about 80 % of the cell volume. This leaves an empty region at the sealed side, where an inlet allows us to set and maintain the air at a constant overpressure (0.1 - 2 bar). For the air trapped inside the cell to relax its overpressure it has to move through the deformable granular medium. Depending on the applied overpressure and initial density of the medium, we observe a range of different behaviors such as seepage through the pore-network with or without an initial compaction of the solid, formation of low density bubbles with rearrangement of particles, granular fingering/fracturing, and erosion inside formed channels/fractures. The experiments are recorded with a high-speed camera at a framerate of 1000 images/s and a resolution of 1024x1024 pixels. We use various image processing techniques to characterize the evolution of the air invasion patterns and the deformations in the surrounding material. The experiments are similar to deformation processes in porous media which are driven by pore fluid overpressure, such as mud volcanoes and hydraulic or pneumatic (gas-induced) fracturing, and the motivation is to increase the understanding of such processes by optical observations. In addition, this setup is an experimental version of the numerical models analyzed by Niebling et al. [1,2], and is useful for comparison with their results. In a directly related project [3], acoustic emissions from the cell plate are recorded during

  17. From rabbit antibody repertoires to rabbit monoclonal antibodies

    PubMed Central

    Weber, Justus; Peng, Haiyong; Rader, Christoph

    2017-01-01

    In this review, we explain why and how rabbit monoclonal antibodies have become outstanding reagents for laboratory research and increasingly for diagnostic and therapeutic applications. Starting with the unique ontogeny of rabbit B cells that affords highly distinctive antibody repertoires rich in in vivo pruned binders of high diversity, affinity and specificity, we describe the generation of rabbit monoclonal antibodies by hybridoma technology, phage display and alternative methods, along with an account of successful humanization strategies. PMID:28336958

  18. Rabbits killing birds revisited.

    PubMed

    Zhang, Jimin; Fan, Meng; Kuang, Yang

    2006-09-01

    We formulate and study a three-species population model consisting of an endemic prey (bird), an alien prey (rabbit) and an alien predator (cat). Our model overcomes several model construction problems in existing models. Moreover, our model generates richer, more reasonable and realistic dynamics. We explore the possible control strategies to save or restore the bird by controlling or eliminating the rabbit or the cat when the bird is endangered. We confirm the existence of the hyperpredation phenomenon, which is a big potential threat to most endemic prey. Specifically, we show that, in an endemic prey-alien prey-alien predator system, eradication of introduced predators such as the cat alone is not always the best solution to protect endemic insular prey since predator control may fail to protect the indigenous prey when the control of the introduced prey is not carried out simultaneously.

  19. Rabbit renotropic system

    SciTech Connect

    Areas, J.; Yun, G.C.; Rahmat, J.; Gersten, D.; Goel, R.; Preuss, H.G.

    1988-04-01

    Elevated levels of a specific renal growth factor, renotropin, have been associated with spontaneous hypertension. To examine this association more closely, we have undertaken the development of a better assay system to characterize and purify renotropin. Sera from rabbits prior to operation (control) and at a specified time after unilateral nephrectomy (uni) were examined for renotropic activity. Comparing the effects of uni to control sera in the same rabbit, significant stimulation of 3H-thymidine incorporation into the DNA of primary rabbit kidney cultures incubated in D-valine medium to eliminate fibroblast growth was noted: at 3 days postoperatively 73% (n = 13), at 7 days 103% (n = 39), at 10 days 130% (n = 31), at 21 days 101% (n = 24), at 42 days 89% (n = 13). All values were at least P less than 0.01. The stimulatory properties were dose-dependent but reached a plateau at high serum concentrations. Comparing CPM/mg protein in uni/control in different concentrations of sera 7 days postoperatively, uni versus control were 67/44 at 5% v/v, 139/72 at 10% v/v, 261/161 at 20% v/v, and 243/136 at 40% v/v. The renotropic effect of uni sera remained after dialysis in incubation medium and after sera were heated in boiling water for 5 minutes. Renal extracts obtained from growing kidneys 7 days postnephrectomy augmented renotropic activity. Atrial natriuretic factor, ouabain, PGF2 alpha, PGE1, and cAMP did not possess renotropic activity. We conclude that the primary rabbit kidney culture assay for renotropin is highly sensitive and will be an important tool to comprehend the role of renotropin in the pathogenesis of hypertension.

  20. Neuro-Fuzzy Control for Pneumatic Servo System

    NASA Astrophysics Data System (ADS)

    Shibata, Satoru; Jindai, Mitsuru; Yamamoto, Tomonori; Shimizu, Akira

    A learning method for acquiring the appropriate fuzzy rules using error back propagation to improve the control performance of the pneumatic servo system is presented in this paper. In the proposed method, two criteria are defined and are adjusted so as to minimize them using error back propagation. These criteria are defined on the fuzzy rules, that is, shapes of membership functions of antecedent clause and real values of consequent clause in the fuzzy controller. Two differentiating coefficients of the plant, used in error back propagation with respect to those criteria, are estimated by the newly established neural network. Moreover, sigmoid function is introduced for the connection of the neural network to compensate for the effect of non-linearity of the system. The method was applied to an existent vertical type pneumatic servo system and proved its effectiveness for practical use.

  1. Massive Pulmonary Calculi Embolism: A Novel Complication of Pneumatic Lithotripsy

    PubMed Central

    Zhang, Lin; Zhou, Yiwu

    2015-01-01

    Abstract Pneumatic lithotripsy is a minimally invasive technique mainly for the treatment of urinary staghorn stones. Previous literatures have reported some therapeutic complications during or after this procedure, but calculi embolism has not been mentioned before. We report here a fatal case of calculi-induced pulmonary embolism in an adult woman who underwent pneumatic lithotripsy. An autopsy did not reveal any evidence of pulmonary embolism. However, light microscopy revealed noticeable presence of calculi in pulmonary arterioles and capillaries, as evidenced by environmental scanning electron microscope and energy dispersive X-ray analysis. The primary determinants of calculi embolism include intrarenal pressure, and volume and viscosity of the calculi fragments formation. Vascular intravasation of smashed calculi might increase pulmonary vascular resistance and hypoxemia and decrease cardiac output. This case report intends to provide information for clinicians to consider the probability of intraoperative calculi embolism during lithotripsies when patients develop typical symptoms of acute pulmonary embolism. PMID:26222867

  2. Pneumatic Regolith Transfer Systems for In-Situ Resource Utilization

    NASA Technical Reports Server (NTRS)

    Mueller, Robert P.; Townsend, Ivan I., III; Mantovani, James G.

    2010-01-01

    One aspect of In-Situ Resource Utilization (lSRU) in a lunar environment is to extract oxygen and other elements from the minerals that make up the lunar regolith. Typical ISRU oxygen production processes include but are not limited to hydrogen reduction, carbothermal and molten oxide electrolysis. All of these processes require the transfer of regolith from a supply hopper into a reactor for chemical reaction processing, and the subsequent extraction of the reacted regolith from the reactor. This paper will discuss recent activities in the NASA ISRU project involved with developing pneumatic conveying methods to achieve lunar regolith simulant transfer under I-g and 1/6-g gravitational environments. Examples will be given of hardware that has been developed and tested by NASA on reduced gravity flights. Lessons learned and details of pneumatic regolith transfer systems will be examined as well as the relative performance in a 1/6th G environment

  3. Development of pneumatic thrust-deflecting powered-lift systems

    NASA Technical Reports Server (NTRS)

    Englar, R. J.; Nichols, J. H., Jr.; Harris, M. J.; Eppel, J. C.; Shovlin, M. D.

    1986-01-01

    Improvements introduced into the Circulation Control Wing/Upper Surface Blowing (CCW/USB) STOL concept (Harris et al., 1982) are described along with results of the full-scale static ground tests and model-scale wind tunnel investigations. Tests performed on the full-scale pneumatic thrust-deflecting system installed on the NASA QSRA aircraft have demonstrated that, relative to the original baseline configuration, a doubling of incremental thrust deflection due to blowing resulted from improvements that increased the blowing span and momentum, as well as from variations in blowing slot height and geometry of the trailing edge. A CCW/Over the Wing model has been built and tested, which was shown to be equivalent to the CCW/USB system in terms of pneumatic thrust deflection and lift generation, while resolving the problem of cruise thrust loss due to exhaust scrubbing on the wing upper surface.

  4. Liquid-metal dip seal with pneumatic spring

    DOEpatents

    Poindexter, Allan M.

    1977-01-01

    An improved liquid-metal dip seal for sealing the annulus between rotating plugs in the reactor vessel head of a liquid-metal fast-breeder nuclear reactor has two legs of differing widths communicating under a seal blade; the wide leg is also in communication with cover gas of the reactor and the narrow leg is also in communication with an isolated plug annulus above the seal. The annulus contains inert gas which acts as a pneumatic spring. Upon increasing cover gas pressure which depresses the level in the wide leg and greatly increases the level in the narrow leg, the pneumatic spring is compressed, and resists further level changes, thus preventing radioactive cover gas from bubbling through the seal.

  5. Pneumatic protection applied to an airbag for para-gliders

    NASA Astrophysics Data System (ADS)

    Raievski, V.; Valladas, G.

    1998-02-01

    We present a theory of pneumatic protection based on the laws of thermodynamics, elasticity and fluid mechanics. A general pneumatic protection system is made up of several communicating compartments, the differences in pressure of the compartments generating a transfer of mass and energy between them. The transfer offers interesting possibilities to improve the performance of the system. An example of this type of protection in aerial sport is the airbag for para-gliders, it is used in this paper to illustrate the theory. As the pressure in the airbag depends uniquely on its volume, the geometric model in the theory can be simplified. Experiments carried out with crash-test dummies equipped with sensors have confirmed the theoretical predictions.

  6. A skin indentation system using a pneumatic bellows.

    PubMed

    Ferguson-Pell, M; Hagisawa, S; Masiello, R D

    1994-01-01

    A pneumatic indentation system using a copper bellows has been developed for physiological studies where a controlled uniaxial compressive force is required to be applied to the surface of the skin. Such a system is useful for studies where the physiological response of the tissues is to be monitored following a known loading history. The indentation system is driven by a vacuum/compression pneumatic pump through solenoid valves under closed-loop computer control. A load cell placed between the indentor and bellows monitors the applied force providing a feedback signal to the computer. The signal from the computer activates the valves supplying air pressure to the bellows, and the applied force is controlled using a digital closed-loop protocol. This system can be used to provide a controlled loading sequence to the skin without utilizing gravitational forces, which allows the subject to keep a more natural position during the experiment.

  7. Relief of vasospasm by intravascular ultraviolet irradiation

    NASA Astrophysics Data System (ADS)

    Nakai, Kanji; Morimoto, Yuji; Ito, Hirotaka; Kominami, Kimito; Matsuo, Hirotaka; Arai, Tsunenori; Kikuchi, Makoto

    1998-05-01

    We investigated the photovasorelaxation with intravascular transluminal irradiation using in vivo model. A 2.5 Fr. catheter was inserted in the femoral artery of a rabbit under anesthesia. A 400 micrometers diameter quartz fiber was inserted through the catheter. The catheter was withdrawn from the distal end to the proximal end of the exposed femoral artery without laser irradiation in order to observe the mechanical dilation by the procedure. The femoral artery lumen was irradiated by a Helium-Cadmium(He-Cd) laser (wavelength; 325 nm) with 8 mW through the fiber during 30 s. We carried out that the laser irradiation produced vasorelaxation (185% on the average) compared with mechanical vasodilation (150% on the average) with angiography. The results suggest that intravascular transluminal irradiation with low-power UV laser might be applicable to the relief of acute arterial vasospasm.

  8. A new sauropod dinosaur from the Early Cretaceous of Tunisia with extreme avian-like pneumatization.

    PubMed

    Fanti, Federico; Cau, Andrea; Hassine, Mohsen; Contessi, Michela

    2013-01-01

    Recent interpretations of the postcranial anatomy of sauropod dinosaurs differ about pneumatic features supporting an avian-like ventilatory system; the most conservative workers reject most postcranial pneumatizations as being unambiguous evidence of abdominal air sacs. Here we describe the first articulated dinosaur skeleton from Tunisia and refer it to a new rebbachisaurid sauropod, Tataouinea hannibalis gen. et sp. nov. The Tunisian specimen shows a complex pattern of caudosacral and pelvic pneumatization--including the first report of an ischial pneumatic foramen among Dinosauria--strongly supporting the presence of abdominal air sacs. Character optimization among Rebbachisauridae indicates that in the caudal vertebrae, pneumatization of the neural arches preceded that of the centra; in the pelvis, pneumatization of the bones adjacent to the sacrum preceded that of more distal elements. Tataouinea was more closely related to European nigersaurines than to otherwise Gondwanan rebbachisaurids; this supports an Afro-European route for rebbachisaurid dispersal.

  9. Development of robot hand with pneumatic actuator and construct of master-slave system.

    PubMed

    Nishino, Shinya; Tsujiuchi, Nobutaka; Koizumi, Takayuki; Komatsubara, Hiroyuki; Kudawara, Tatuwo; Shimizu, Mikio

    2007-01-01

    Recently, research has concentrated on robots that can coexist with people and be of use to them. Such a robot needs to be both safe and flexible. Here, we use a pneumatic actuator as the driving source of a robot hand. We develop a pneumatic actuator driven by low pressure because we consider that the conventional pneumatic actuator is inadequate for the driving source of a robot hand. First, we examine the characteristics of our new pneumatic actuator. Next, we develop a five-fingered robot hand using this pneumatic actuator. The robot hand produced is both safe and flexible. We construct a master-slave system to enable the robot hand to perform the same operations as a human hand. Next, we make a joint model that has one degree of freedom using a pneumatic actuator. We construct a control system for the joint model and verify its control performance.

  10. Dynamic Analysis of Sounding Rocket Pneumatic System Revision

    NASA Technical Reports Server (NTRS)

    Armen, Jerald

    2010-01-01

    The recent fusion of decades of advancements in mathematical models, numerical algorithms and curve fitting techniques marked the beginning of a new era in the science of simulation. It is becoming indispensable to the study of rockets and aerospace analysis. In pneumatic system, which is the main focus of this paper, particular emphasis will be placed on the efforts of compressible flow in Attitude Control System of sounding rocket.

  11. Comprehensive integration of homogeneous bioassays via centrifugo-pneumatic cascading.

    PubMed

    Godino, Neus; Gorkin, Robert; Linares, Ana V; Burger, Robert; Ducrée, Jens

    2013-02-21

    This work for the first time presents the full integration and automation concept for a range of bioassays leveraged by cascading a centrifugo-pneumatic valving scheme to sequentially move several liquids through shared channel segments for multi-step sample preparation into the detection zone. This novel centrifugo-pneumatic liquid handling significantly simplifies system manufacture by obviating the need for complex surface functionalization procedures or hybrid material integration, as it is common in conventional valving methods such as capillary burst valves or sacrificial valves. Based on the centrifugo-pneumatic valving scheme, this work presents a toolkit of operational elements implementing liquid loading/transfer, metering, mixing and sedimentation in a microstructured polymer disc. As a proof of concept for the broad class of homogeneous bioassays, the full integration and automation of a colorimetric nitrate/nitrite test for the detection of clinically relevant nitric oxide (NO) in whole blood is implemented. First, 40 μL of plasma is extracted from a 100 μL sample of human blood, incubated for one hour with the enzymatic mixture (60 μL), and finally reacted with 100 μL of colorimetric (Greiss) reagents. Following just a single loading phase at the beginning of the process, all of these steps are automated through the centrifugo-pneumatic cascade with a high level of flow control and synchronization. Our system shows good correlation with controls up to 50 μM of nitrate, which adequately covers the healthy human range (4 to 45.3 μM).

  12. Electric versus pneumatic power in hand prostheses for children.

    PubMed

    Plettenburg, D H

    1989-01-01

    Most externally powered hand prostheses for children with a unilateral congenital below-elbow amputation are myoelectrically controlled. All of them are electrically powered. Despite the success of fitting children with this kind of prostheses, there are some disadvantages: prosthetic weight is high, operating speed is low, the system is vulnerable and its size prohibits fitting it to patients with a long fore-arm stump. It will be shown that pneumatic power can overcome most of these disadvantages.

  13. Pneumatic Muscle Actuated Equipment for Continuous Passive Motion

    NASA Astrophysics Data System (ADS)

    Deaconescu, Tudor T.; Deaconescu, Andrea I.

    2009-10-01

    Applying continuous passive rehabilitation movements as part of the recovery programme of patients with post-traumatic disabilities of the bearing joints of the inferior limbs requires the development of new high performance equipment. This chapter discusses a study of the kinematics and performance of such a new, continuous passive motion based rehabilitation system actuated by pneumatic muscles. The utilized energy source is compressed air ensuring complete absorption of the end of stroke shocks, thus minimizing user discomfort.

  14. Evaluation of unsaturated zone air permeability through pneumatic tests

    USGS Publications Warehouse

    Baehr, Arthur L.; Hult, Marc F.

    1991-01-01

    Predicting the steady state distribution of air pressure in the unsaturated zone resulting from a pneumatic test provides a method for determining air-phase permeability. This technique is analogous to the inverse problem of well hydraulics; however, air flow is more complicated than ground water flow because of air compressibility, the Klinkenberg effect, variations in air density and viscosity that result from temperature fluctuations in the unsaturated zone and the possibility of inducing water movement during the pneumatic test. An analysis of these complicating factors reveals that, when induced water movement can be neglected, a linear version of the airflow equation can provide an appropriate approximation for the purpose of determining air-phase permeability. Two analytical solutions for steady state, two-dimensional, axisymmetric airflow to a single well partially screened in the unsaturated zone are developed. One solution applies where there is a stratum of relatively low air permeability, separating the stratum in which the well is completed, from the atmosphere. The other solution applies where there is no separating stratum between the domain and atmosphere. In both situations the water table forms the lower horizontal boundary. Applications of both solutions to determine air permeability from data collected during pneumatic tests are presented.

  15. A Model-Based Prognostics Approach Applied to Pneumatic Valves

    NASA Technical Reports Server (NTRS)

    Daigle, Matthew J.; Goebel, Kai

    2011-01-01

    Within the area of systems health management, the task of prognostics centers on predicting when components will fail. Model-based prognostics exploits domain knowledge of the system, its components, and how they fail by casting the underlying physical phenomena in a physics-based model that is derived from first principles. Uncertainty cannot be avoided in prediction, therefore, algorithms are employed that help in managing these uncertainties. The particle filtering algorithm has become a popular choice for model-based prognostics due to its wide applicability, ease of implementation, and support for uncertainty management. We develop a general model-based prognostics methodology within a robust probabilistic framework using particle filters. As a case study, we consider a pneumatic valve from the Space Shuttle cryogenic refueling system. We develop a detailed physics-based model of the pneumatic valve, and perform comprehensive simulation experiments to illustrate our prognostics approach and evaluate its effectiveness and robustness. The approach is demonstrated using historical pneumatic valve data from the refueling system.

  16. A pneumatic orthotic cranial molding helmet for correcting positional plagiocephaly.

    PubMed

    Lee, Walter T; Richards, Kirsten; Redhed, James; Papay, Frank A

    2006-01-01

    The objective of this study was o determine the efficacy of a newly developed pneumatic orthotic cranial molding helmet for correcting positional plagiocephaly. The design was retrospective and the setting was a tertiary care center. Subjects were all patients in whom positional plagiocephaly has been diagnosed and who have been fitted by the Orthotics and Prosthetics Department for the helmet. Diagonal cranial lengths and widths were measured at each visit. Analysis included the calculation of the ratio change in oblique diameters compared with time, patient's age, and head circumference. Seventy-five patients met inclusion criteria (50 boys, 25 girls). Patients with pneumatic orthotic cranial molding helmet therapy had significantly improved outcomes as compared with pretreatment measurements (P < or = 0.0001). The helmet did not limit cranial growth as evidenced by significant normalization of the oblique measurement ratio when compared with increasing cranial circumference and age (P = 0.0003, P < or = 0.0001, respectively). The pneumatic orthotic cranial molding helmet successfully corrects positional plagiocephaly and does not hinder cranial growth.

  17. Design and Control of a Pneumatically Actuated Transtibial Prosthesis

    PubMed Central

    Zheng, Hao; Shen, Xiangrong

    2015-01-01

    This paper presents the design and control of a pneumatically actuated transtibial prosthesis, which utilizes a pneumatic cylinder-type actuator to power the prosthetic ankle joint to support the user's locomotion. The pneumatic actuator has multiple advantages over the traditional electric motor, such as light weight, low cost, and high power-to-weight ratio. The objective of this work is to develop a compact and lightweight transtibial prosthesis, leveraging the multiple advantages provided by this highly competitive actuator. In this paper, the design details of the prosthesis are described, including the determination of performance specifications, the layout of the actuation mechanism, and the calculation of the torque capacity. Through the authors’ design calculation, the prosthesis is able to provide sufficient range of motion and torque capacity to support the locomotion of a 75 kg individual. The controller design is also described, including the underlying biomechanical analysis and the formulation of the finite-state impedance controller. Finally, the human subject testing results are presented, with the data indicating that the prosthesis is able to generate a natural walking gait and sufficient power output for its amputee user. PMID:26146497

  18. Effect of pneumatic compression on fibrinolysis after total hip arthroplasty.

    PubMed

    Macaulay, William; Westrich, Geoffrey; Sharrock, Nigel; Sculco, Thomas P; Jhon, Peter H; Peterson, Margaret G E; Salvati, Eduardo A

    2002-06-01

    The purpose of this prospective randomized clinical study was to investigate the enhanced systemic fibrinolysis mechanism of venous thrombosis prevention by pneumatic compression after total hip arthroplasty. Fifty patients were randomized into one of two groups (one with pneumatic compression [n=25] and one without [n=25]). Blood was drawn from a radial arterial line immediately preoperatively (baseline), at skin closure, and 8 hours and 22 hours after the baseline sample. Serum determinations of antigen of tissue plasminogen activator and plasminogen activator inhibitor-1 were done using enzyme-linked immunosorbent assays. These data do not support the enhancement of systemic fibrinolysis mechanism for lowering thromboembolic risk after total hip arthroplasty by pneumatic compression devices. The results of this study showed no differences that were statistically significant between the two groups. The greatest difference was observed 8 hours after surgery for the plasminogen activator inhibitor-1 marker, (28.12 with compression versus 22.07 ng/mL without); however, this result was not statistically significant. The beneficial effect of mechanical compression is more likely achieved through increased flow, local fibrinolytic effects, or both.

  19. Formulation of a minimum variance deconvolution technique for compensation of pneumatic distortion in pressure sensing devices

    NASA Technical Reports Server (NTRS)

    Whitmore, Stephen A.

    1990-01-01

    Increasingly, aircraft system designs require that aerodynamic parameters derived from pneumatic measurements be employed as control-system feedbacks. Such high frequency pressure measurements' accuracy is compromised by pressure distortion due to frictional attenuation and pneumatic resonance within the sensing system. A pneumatic distortion model is here formulated and reduced to a low-order state-variable model which retains most of the full model's dynamic characteristics. This reduced-order model is coupled with standard results from minimum variance estimation theory to develop an algorithm to compensate for pneumatic-distortion effects.

  20. Clinical Effect of Endoscopic Pneumatic Dilation for Achalasia.

    PubMed

    Cheng, Peng; Shi, Hai; Zhang, Yanjie; Zhou, Huabang; Dong, Jinhua; Cai, Yiting; Hu, Xing; Dai, Qiang; Yang, Wenyan

    2015-07-01

    Although pneumatic dilation is an accepted method for the treatment of achalasia, this therapy has high recurrence and complication rates, and prolonged follow-up studies on the parameters associated with various outcomes are rare. In this prospective 10-year follow-up study, a satisfactory therapeutic effect was achieved without serious complications. We report the therapeutic experience with pneumatic dilation, having aimed to evaluate the long-term clinical safety and efficacy of pneumatic dilation. In total, 35 consecutive patients with idiopathic achalasia who underwent pneumatic dilation were followed up at regular intervals in person or by a phone interview over a 10-year period. The mean duration of the follow-up was 43.03 ± 26.34 months (range 6-120 months). Remission was assessed by the dysphagia classification and symptom scores. Patients' clinical symptom scores were calculated before and at 6 to 36  months, 37 to 60  months, and >60  months after therapy. The influence of the patients' age, gender, and disease duration on the therapeutic effect was analyzed. The success rate of the operation was 97.2% (35/36), without massive hemorrhaging, perforation or other serious complications. Dysphagia after the therapy was significantly eased (P < 0.01). In total, 35 patients have been followed up for 6 to 36  months after therapy, 21 cases for 37 to 60  months, and 5 cases for >60  months, and the patients' symptom scores separately decreased significantly compared with the pretherapy scores (P < 0.01). For these patients, the 6 to 36  months remission rate was 85.7% (30/35), the 37 to 60  months rate was 61.9% (13/21), and the >60  months rate was 40% (2/5). The dilation effect had no relationship to the patient's age, gender, and disease duration (P > 0.05). The patients in 30 cases (85.7%) were successfully treated with a single dilation, in 4 cases (11.4%) with 2 dilations, and in 1 case (2.9%) with 3 dilations. These

  1. [Is pneumatic sample transport system also a carrier for microorganisms?].

    PubMed

    Alpat, Saygin Nayman; Ozgüneş, Ilhan; Aybey, Aşkin Derya; Ertem, Osman Turgut; Akşit, Filiz

    2009-07-01

    The purpose of this study was to evaluate the possible infection and contamination risk of the pneumatic system used in our hospital and to establish essential infection control measures. The study was conducted in a quaternary health care center with 1.000 bed capacity. A total of 614 specimens were taken 2 times weekly from the pneumatic transport system and its carriers at 22 wards, 5 intensive care units, 3 laboratories, 2 blood taking units, and pharmacy. Samples were also obtained from the fingertips of 33 subjects using the system, before and after contact with the carriers. A questionnaire that consisted of 8 questions was applied to 224 subjects who worked in those units, evaluating the degree of compliance to the obligations for the cleaning of the pneumatic system and carriers and their approach in case of visible pollution at the system. Bacterial growth was observed in 15.2% (45/296) of samples in the 1st week and 7.6% (18/238) of the samples in the 2nd week, making a total of 11.8% (63/534) bacterial growth. No growth was detected from the areas where the carriers were placed. Of these 69.8% were coagulase negative staphylococci, 11.1% diphteroids, 7.9% Acinetobacter Iwoffii, 4.8% Staphylococcus aureus, 4.8% Bacillus spp. and 1.6% Enterococcus durans. Acinetobacter baumannii and Aspergillus were detected at two fingertip samples taken before the contact with carriers, while again A. baumannii and Enterobacter cloacae were detected at the samples following contact. Moreover, 31.3% of the subjects noted that they cleaned the carriers only if any visible contamination was present. In addition, 14.3% reported that they have encountered broken or spilled up material in the system for more than 5 times, 10.3% reported that they followed the instructions in case of presence of infected material inside the carriers, 23.7% reported that they always washed their hands after any contact with the carriers, 9.8% noted that they always used gloves during contact

  2. Clinical Effect of Endoscopic Pneumatic Dilation for Achalasia

    PubMed Central

    Cheng, Peng; Shi, Hai; Zhang, Yanjie; Zhou, Huabang; Dong, Jinhua; Cai, Yiting; Hu, Xing; Dai, Qiang; Yang, Wenyan

    2015-01-01

    Abstract Although pneumatic dilation is an accepted method for the treatment of achalasia, this therapy has high recurrence and complication rates, and prolonged follow-up studies on the parameters associated with various outcomes are rare. In this prospective 10-year follow-up study, a satisfactory therapeutic effect was achieved without serious complications. We report the therapeutic experience with pneumatic dilation, having aimed to evaluate the long-term clinical safety and efficacy of pneumatic dilation. In total, 35 consecutive patients with idiopathic achalasia who underwent pneumatic dilation were followed up at regular intervals in person or by a phone interview over a 10-year period. The mean duration of the follow-up was 43.03 ± 26.34 months (range 6–120 months). Remission was assessed by the dysphagia classification and symptom scores. Patients’ clinical symptom scores were calculated before and at 6 to 36 months, 37 to 60 months, and >60 months after therapy. The influence of the patients’ age, gender, and disease duration on the therapeutic effect was analyzed. The success rate of the operation was 97.2% (35/36), without massive hemorrhaging, perforation or other serious complications. Dysphagia after the therapy was significantly eased (P < 0.01). In total, 35 patients have been followed up for 6 to 36 months after therapy, 21 cases for 37 to 60 months, and 5 cases for >60 months, and the patients’ symptom scores separately decreased significantly compared with the pretherapy scores (P < 0.01). For these patients, the 6 to 36 months remission rate was 85.7% (30/35), the 37 to 60 months rate was 61.9% (13/21), and the >60 months rate was 40% (2/5). The dilation effect had no relationship to the patient's age, gender, and disease duration (P > 0.05). The patients in 30 cases (85.7%) were successfully treated with a single dilation, in 4 cases (11.4%) with 2 dilations, and in 1 case (2.9%) with 3 dilations

  3. 76 FR 6603 - Certain New Pneumatic Off-the-Road Tires From the People's Republic of China: Notice of Extension...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-02-07

    ... pneumatic off-the-road tires (``OTR tires'') from the People's Republic of China (``PRC'') for the period... on OTR tires from the PRC. See Certain New Pneumatic Off-the-Road Tires From the People's Republic...

  4. 14 CFR 23.1416 - Pneumatic de-icer boot system.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... intended function under any normal system operating temperature or pressure, and (c) Means to indicate to... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Pneumatic de-icer boot system. 23.1416... Safety Equipment § 23.1416 Pneumatic de-icer boot system. If certification with ice protection...

  5. 46 CFR 108.409 - Location and spacing of tubing in pneumatic fire detection system.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... detection system. 108.409 Section 108.409 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS DESIGN AND EQUIPMENT Fire Extinguishing Systems § 108.409 Location and spacing of tubing in pneumatic fire detection system. (a) All tubing in a pneumatic fire...

  6. His majesty's subjects: from laboratory to human experiment in pneumatic chemistry.

    PubMed

    Stewart, Larry

    2009-09-20

    Experiments in pneumatic chemistry paved the way for medical innovation in the last quarter of the eighteenth century. Thomas Beddoes and James Watt were instrumental in the spread of the use of new gas chemistry in pneumatic therapy, but they were far from alone. There was no shortage of experimental subjects, as the practice was quickly taken up by medics throughout Britain.

  7. A quantitative method for the evaluation of three-dimensional structure of temporal bone pneumatization

    PubMed Central

    Hill, Cheryl A.; Richtsmeier, Joan T.

    2010-01-01

    Temporal bone pneumatization has been included in lists of characters used in phylogenetic analyses of human evolution. While studies suggest that the extent of pneumatization has decreased over the course of human evolution, little is known about the processes underlying these changes or their significance. In short, reasons for the observed reduction and the potential reorganization within pneumatized spaces are unknown. Technological limitations have limited previous analyses of pneumatization in extant and fossil species to qualitative observations of the extent of temporal bone pneumatization. In this paper, we introduce a novel application of quantitative methods developed for the study of trabecular bone to the analysis of pneumatized spaces of the temporal bone. This method utilizes high-resolution X-ray computed tomography (HRXCT) images and quantitative software to estimate three-dimensional parameters (bone volume fractions, anisotropy, and trabecular thickness) of bone structure within defined units of pneumatized spaces. We apply this approach in an analysis of temporal bones of diverse but related primate species, Gorilla gorilla, Pan troglodytes, Homo sapiens, and Papio hamadryas anubis, to illustrate the potential of these methods. In demonstrating the utility of these methods, we show that there are interspecific differences in the bone structure of pneumatized spaces, perhaps reflecting changes in the localized growth dynamics, location of muscle attachments, encephalization, or basicranial flexion. PMID:18715622

  8. 46 CFR 128.240 - Hydraulic or pneumatic power and control-materials and pressure design.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 4 2011-10-01 2011-10-01 false Hydraulic or pneumatic power and control-materials and...) OFFSHORE SUPPLY VESSELS MARINE ENGINEERING: EQUIPMENT AND SYSTEMS Materials and Pressure Design § 128.240 Hydraulic or pneumatic power and control—materials and pressure design. (a) Each standard piping...

  9. 49 CFR 571.117 - Standard No. 117; Retreaded pneumatic tires.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... HIGHWAY TRAFFIC SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION FEDERAL MOTOR VEHICLE SAFETY STANDARDS Federal Motor Vehicle Safety Standards § 571.117 Standard No. 117; Retreaded pneumatic tires. S1. Scope... passenger car tires. S2. Purpose. The purpose of this standard is to require retreaded pneumatic...

  10. 21 CFR 874.4250 - Ear, nose, and throat electric or pneumatic surgical drill.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Ear, nose, and throat electric or pneumatic... AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES EAR, NOSE, AND THROAT DEVICES Surgical Devices § 874.4250 Ear, nose, and throat electric or pneumatic surgical drill. (a) Identification. An ear, nose,...

  11. 21 CFR 874.4250 - Ear, nose, and throat electric or pneumatic surgical drill.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Ear, nose, and throat electric or pneumatic... AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES EAR, NOSE, AND THROAT DEVICES Surgical Devices § 874.4250 Ear, nose, and throat electric or pneumatic surgical drill. (a) Identification. An ear, nose,...

  12. 21 CFR 874.4250 - Ear, nose, and throat electric or pneumatic surgical drill.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Ear, nose, and throat electric or pneumatic... AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES EAR, NOSE, AND THROAT DEVICES Surgical Devices § 874.4250 Ear, nose, and throat electric or pneumatic surgical drill. (a) Identification. An ear, nose,...

  13. 49 CFR 571.129 - Standard No. 129; New non-pneumatic tires for passenger cars.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... passenger cars. 571.129 Section 571.129 Transportation Other Regulations Relating to Transportation...-pneumatic tires for passenger cars. S1Scope. This standard specifies tire dimensions and laboratory test... applies to new temporary spare non-pneumatic tires for use on passenger cars. S3Definitions. Carcass...

  14. 49 CFR 571.129 - Standard No. 129; New non-pneumatic tires for passenger cars.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... passenger cars. 571.129 Section 571.129 Transportation Other Regulations Relating to Transportation...-pneumatic tires for passenger cars. S1Scope. This standard specifies tire dimensions and laboratory test... applies to new temporary spare non-pneumatic tires for use on passenger cars. S3Definitions. Carcass...

  15. 49 CFR 571.129 - Standard No. 129; New non-pneumatic tires for passenger cars.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... passenger cars. 571.129 Section 571.129 Transportation Other Regulations Relating to Transportation...-pneumatic tires for passenger cars. S1Scope. This standard specifies tire dimensions and laboratory test... applies to new temporary spare non-pneumatic tires for use on passenger cars. S3Definitions. Carcass...

  16. 49 CFR 571.129 - Standard No. 129; New non-pneumatic tires for passenger cars.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... passenger cars. 571.129 Section 571.129 Transportation Other Regulations Relating to Transportation...-pneumatic tires for passenger cars. S1Scope. This standard specifies tire dimensions and laboratory test... applies to new temporary spare non-pneumatic tires for use on passenger cars. S3Definitions. Carcass...

  17. 40 CFR 60.253 - Standards for pneumatic coal-cleaning equipment.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 7 2014-07-01 2014-07-01 false Standards for pneumatic coal-cleaning... PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Coal Preparation and Processing Plants § 60.253 Standards for pneumatic coal-cleaning equipment. (a) On and...

  18. 40 CFR 60.253 - Standards for pneumatic coal-cleaning equipment.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 6 2011-07-01 2011-07-01 false Standards for pneumatic coal-cleaning... PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Coal Preparation and Processing Plants § 60.253 Standards for pneumatic coal-cleaning equipment. (a) On and...

  19. 40 CFR 60.253 - Standards for pneumatic coal-cleaning equipment.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 7 2013-07-01 2013-07-01 false Standards for pneumatic coal-cleaning... PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Coal Preparation and Processing Plants § 60.253 Standards for pneumatic coal-cleaning equipment. (a) On and...

  20. 40 CFR 60.253 - Standards for pneumatic coal-cleaning equipment.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 7 2012-07-01 2012-07-01 false Standards for pneumatic coal-cleaning... PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Coal Preparation and Processing Plants § 60.253 Standards for pneumatic coal-cleaning equipment. (a) On and...

  1. 40 CFR 60.253 - Standards for pneumatic coal-cleaning equipment.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 6 2010-07-01 2010-07-01 false Standards for pneumatic coal-cleaning... PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Coal Preparation and Processing Plants § 60.253 Standards for pneumatic coal-cleaning equipment. (a) On and...

  2. Oculoscopy in Rabbits and Rodents.

    PubMed

    Jekl, Vladimir; Hauptman, Karel; Knotek, Zdenek

    2015-09-01

    Ophthalmic diseases are common in rabbits and rodents. Fast and definitive diagnosis is imperative for successful treatment of ocular diseases. Ophthalmic examination in rabbits and rodents can be challenging. Oculoscopy offers great magnification for the examination of the ocular structures in such animals, including the evaluation of cornea, anterior eye chamber, limbus, iris, lens, and retina. To date, oculoscopy has been described only sporadically and/or under experimental conditions. This article describes the oculoscopy technique, normal and abnormal ocular findings, and the most common eye disorders diagnosed with the aid of endoscopy in rabbits and rodents.

  3. Muscle- and pneumatic-powered counterpulsating LVADs: a pilot study.

    PubMed

    Wilde, J C; van Loon, J; Bishop, N D; Shelton, A D; Marten, C; Kolff, W J; Stephenson, L; Baciewicz, F; Nakajima, H; Thomas, G

    1994-03-01

    There is a worldwide interest in supporting the failing heart with a skeletal muscle by either wrapping it around the natural heart (dynamic cardiomyoplasty) or by constructing a skeletal muscle ventricle (SMV) used for counterpulsation. Conventional cardiomyoplasty in many clinics carries an operative mortality rate of 15-20% partly because it requires 6 weeks to train the muscle to contract continually. A flexible, pear-shaped blood pump with an inflatable air chamber was designed and made around which a muscle can be wrapped. The advantage of our design is that it can also be driven by pneumatic power, immediately supporting the circulation of a seriously ill patient while that patient is still on the operating table. After a period of time to allow for revascularization and the subsequent training of the muscle, the external pneumatic power can be gradually discontinued. Then the assisted patient becomes tether-free. If, at any time, the muscle power fails, the pneumatic-powered mechanism can be reactivated. In the preferred approach, the blood pump is connected to the aorta for diastolic counterpulsation. A muscle can either be wrapped around the blood pump directly, or around one of two separate muscle pouches connected to the blood pump. To facilitate surgery, a large pouch is inserted under the musculus latissimus dorsi, which is connected to a blood pump. When stimulated, the muscle will contract over the pouch compressing it and providing power to the blood pump. If it is found that the pressure generated in the pouch cannot meet the aortic blood pressure, it can be augmented by using a pressure amplifier.(ABSTRACT TRUNCATED AT 250 WORDS)

  4. [Pneumatic dilatation of achalasia: local experience in treating 41 patients].

    PubMed

    Honein, Khalil; Slim, Rita; Yaghi, César; Kheir, Bahaa; Bou Jaoudé, Joseph; Sayegh, Raymond

    2007-01-01

    L'achalasia is the best known primary motor disorder of the esophagus in which the lower esophageal sphincter (LES) has abnormally high resting pressure and incomplete relaxation with swallowing. Pneumatic dilatation (PD) remains the first choice of treatment. Our aim was to report, in a retrospective way, our experience in treating with pneumatic dilatation 41 achalasia patients admitted to the gastroenterology unit at Hôtel-Dieu de France (HDF) hospital between 1994 and 2004. A total of 46 dilatations were performed in 41 patients with achalasia [20 males and 21 females, the mean age was 46.8 years (range, 15-90)]. All patients underwent an initial dilatation by inflating a 35 mm balloon to 7 psi three times successively under fluoroscopic control. The need for subsequent dilatation with the same technique or for surgical treatment was based on symptom assessment. The mean follow-up period was 36.7 months (3 mo-7 years). Among the patients whose follow-up information was available, a satisfactory result was achieved in 29 patients (80.5%) after only one or two sessions of pneumatic dilatation. Esophageal perforation as a short-term complication was observed in one patient (2.17%). Seven patients were referred for surgery (one for esophageal perforation and six for persistent or recurrent symptoms). In conclusion, performing balloon dilatation under fluoroscopic observation is simple, safe and efficacious for treating patients with achalasia. Referral to repeated PD or to surgical myotomy should be discussed in case of no response to a first session of PD.

  5. 77 FR 6536 - Certain New Pneumatic Off-the-Road Tires From the People's Republic of China: Notice of Extension...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-02-08

    ... International Trade Administration Certain New Pneumatic Off-the-Road Tires From the People's Republic of China... administrative review of the antidumping duty order on certain new pneumatic off-the-road tires (``off-the-road... administrative review of the antidumping order on off- the-road tires from the PRC. See Certain New Pneumatic...

  6. 75 FR 49459 - Certain New Pneumatic Off-The-Road Tires from the People's Republic of China: Notice of Amended...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-08-13

    ... International Trade Administration A-570-912 Certain New Pneumatic Off-The-Road Tires from the People's Republic... determination in the antidumping investigation on certain new pneumatic off-the-road tires (``OTR tires'') from.... See Certain New Pneumatic Off-The-Road-Tires from the People's Republic of China: Final...

  7. 75 FR 31422 - Certain New Pneumatic Off-The-Road Tires from the People's Republic of China: Notice of Decision...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-06-03

    ... International Trade Administration A-570-912 Certain New Pneumatic Off-The-Road Tires from the People's Republic... antidumping investigation on certain new pneumatic off-the-road tires (``OTR tires'') from the People's... Pneumatic Off-The-Road-Tires from the People's Republic of China: Final Affirmative Determination of...

  8. 75 FR 24884 - Certain New Pneumatic Off-the-Road Tires from the People's Republic of China: Partial Rescission...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-05-06

    ...., Tianjin Wanda Tyre Co., Ltd., and Triangle Tyre Co., Ltd. See Certain New Pneumatic Off-the-Road Tires... International Trade Administration Certain New Pneumatic Off-the-Road Tires from the People's Republic of China... Pneumatic Off-the-Road Tires (OTR Tires) from the People's Republic of China (PRC) for the period...

  9. Compact, Non-Pneumatic Rock-Powder Samplers

    NASA Technical Reports Server (NTRS)

    Sherrit, Stewart; Bar-Cohen, Yoseph; Badescu, Mircea; Bao, Xiaoqi; Chang, Zensheu; Jones, Christopher; Aldrich, Jack

    2008-01-01

    Tool bits that automatically collect powdered rock, permafrost, or other hard material generated in repeated hammering action have been invented. The present invention pertains to the special case in which it is desired to collect samples in powder form for analysis by x-ray diffraction and possibly other techniques. The present invention eliminates the need for both the mechanical collection equipment and the crushing chamber and the pneumatic collection equipment of prior approaches, so that it becomes possible to make the overall sample-acquisition apparatus more compact.

  10. PNEUMATIC MICROVALVE FOR ELECTROKINETIC SAMPLE PRECONCENTRATION AND CAPILLARY ELECTROPHORESIS INJECTION

    SciTech Connect

    Cong, Yongzheng; Rausch, Sarah J.; Geng, Tao; Jambovane, Sachin R.; Kelly, Ryan T.

    2014-10-27

    Here we show that a closed pneumatic microvalve on a PDMS chip can serve as a semipermeable membrane under an applied potential, enabling current to pass through while blocking the passage of charged analytes. Enrichment of both anionic and cationic species has been demonstrated, and concentration factors of ~70 have been achieved in just 8 s. Once analytes are concentrated, the valve is briefly opened and the sample is hydrodynamically injected onto an integrated microchip or capillary electrophoresis (CE) column. In contrast to existing preconcentration approaches, the membrane-based method described here enables both rapid analyte concentration as well as high resolution separations.

  11. Computed tomography of temporal bone pneumatization. 1. Normal pattern and morphology

    SciTech Connect

    Virapongse, C.; Sarwar, M.; Bhimani, S.; Sasaki, C.; Shapiro, R.

    1985-09-01

    The pneumatization of 141 normal temporal bones on computed tomography (CT) was evaluated in 100 patients. Because of the controversy surrounding the sclerotic squamomastoid (mastoid), temporal bones with this finding were discarded. A CT index of pneumatization was based on the pneumatized area and the number of cells seen within a representative scanning section. Results suggest that squamomastoid pneumatization follows the classic normal distribution and does not correlate with age, gender, or laterality. A high degree of symmetry was found in 41 patients who had both ears examined. Air-cell configuration was variable. Air-cell size tended to increase progressively from the mastoid antrum. The scutum pseudotumor appearance caused by incomplete pneumatization was seen frequently, and should not be mistaken for mastoiditis or an osteoma. Thick sections producing partial-volume effect may also produce this spurious finding. Therefore, when searching for mucosal thickening due to mastoiditis, large air cells should preferably be analyzed.

  12. Urethral healing in rabbits.

    PubMed

    Scherz, H C; Kaplan, G W; Boychuk, D I; Landa, H M; Haghighi, P

    1992-08-01

    We studied urethral healing in New Zealand white rabbits by histological examination after insult (urethral catheter) or injury (urethrotomy) specifically for acute and chronic inflammation, fibrosis, fistulas, squamous metaplasia, foreign body giant cells and urethral dilatation. Urethral catheterization resulted in increased inflammation and fibrosis compared to noncatheterized animals. Skin closure techniques and materials resulted in an inflammatory response that may extend to and involve the urethra. Minor differences in suture size were not an important variable but the persistence of suture material may have a role in the degree of inflammation and the formation of foreign body giant cells. Transepithelial closure techniques drag epithelial cells into subcutaneous tissues and may predispose to fistula formation.

  13. Real gas effects on charging and discharging processes of high pressure pneumatics

    NASA Astrophysics Data System (ADS)

    Luo, Yuxi; Wang, Xuanyin; Ge, Yaozheng

    2013-01-01

    The high pressure pneumatic system has been applied to special industries. It may cause errors when we analyze high pressure pneumatics under ideal gas assumption. However, the real gas effect on the performances of high pressure pneumatics is seldom investigated. In this paper, the real gas effects on air enthalpy and internal energy are estimated firstly to study the real gas effect on the energy conversion. Under ideal gas assumption, enthalpy and internal energy are solely related to air temperature. The estimation result indicates that the pressure enthalpy and pressure internal energy of real pneumatic air obviously decrease the values of enthalpy and internal energy for high pressure pneumatics, and the values of pressure enthalpy and pressure internal energy are close. Based on the relationship among pressure, enthalpy and internal energy, the real gas effects on charging and discharging processes of high pressure pneumatics are estimated, which indicates that the real gas effect accelerates the temperature and pressure decreasing rates during discharging process, and decelerates their increasing rates during charging process. According to the above analysis, and for the inconvenience in building the simulation model for real gas and the difficulty of measuring the detail thermal capacities of pneumatics, a method to compensate the real gas effect under ideal gas assumption is proposed by modulating the thermal capacity of the pneumatic container in simulation. The experiments of switching expansion reduction (SER) for high pressure pneumatics are used to verify this compensating method. SER includes the discharging process of supply tanks and the charging process of expansion tank. The simulated and experimental results of SER are highly consistent. The proposed compensation method provides a convenient way to obtain more realistic simulation results for high pressure pneumatics.

  14. [Functional alterations in the retina following a 10 Gy gamma irradiation localized in the eye].

    PubMed

    Bagot, J D; Courant, D; Court, L

    1980-11-17

    A single-eye irradiation of 10 Gy (0.8 Gy. min-1) induces impairments of the electrical responses of the rabbit retina in dark adaptation. These are associated with reversible alteration of the photoreceptors and the preganglionic neurons and a disturbance of all the mechanisms of adaptation. Possible relationships between these functional alterations and the effects of irradiation are discussed.

  15. The cottontail rabbits of Virginia

    USGS Publications Warehouse

    Llewellyn, L.M.; Handley, C.O.

    1945-01-01

    Five races of cottontail rabbits belonging to three species occur in Virginia. One of them, the Mearns cottontail (Sylvilagus floridanus mearnsi), is reported here for the first time. It occurs in six southwestern counties of the state, while the eastern cottontail (S. f. mallurus) occurs in the remainder of the state with the exception of Smith and Fishermans islands off the eastern coast of Cape Charles, where it is replaced by Hitchens cottontail (S. f. hitchensi). The New England cottontail (S. transitionalis) is found on the higher mountain peaks, above 3000 feet, and the swamp rabbit (S. palustris) occurs in the Dismal Swamp region of southeastern Virginia.....The height of the breeding season for the eastern cottontail in Virginia is March and April, but breeding continues through the entire year except in December and January. The average litter size based on embryo counts was 4.7. The sex ratio of 234 specimens from all parts of the state, taken mostly in the December to February period, was 53 males to 47 females. That of a group of 145 rabbits live-trapped at Blacksburg during February and Marchwas 58 males to 42 females. The figures show that males are more active than females during the winter months, and therefore are more easily taken then....In transplanting cottontails from one section of the state to another, it is recommended that only cottontails of the same race as those originally present in the region being restocked be released there....Tularemia is not a common disease among rabbits in Virginia, but the rabbit ticks are often carriers of the disease and may transmit it to rabbits. Rabbit ticks are also found to be carriers of Rocky Mountain fever and American Q. fever. After the ticks drop off the rabbits to hibernate in the ground, which is likely to occur during mid-winter in Virginia, there is relatively little danger of humans contracting tularemia by contact with rabbits. Present laws in Virginia which prohibit rabbit hunting until the

  16. Performance optimization of a pneumatic wave energy conversion device

    NASA Astrophysics Data System (ADS)

    Surko, S. W.

    1982-08-01

    The purpose of this study was, for the first time, to optimize the performance of a pneumatic wave energy conversion device. The experiments of Jolly and Newmaster (1979) and Trop and Casey (1980) left a capture chamber and turbine for further investigation. To optimize the system performance the turbine had to be first analyzed so that its power performance curves could be determined. These curves were needed to help define the possible overall performance of the system, and for the impedance matching of the system necessary for performance optimization. With this knowledge, an appropriate generator was purchased and a generator-turbine linkage designed and built. The completed system was then analyzed in the 380 ft wave tank at the U.S. Naval Academy to establish its optimum performance. From the research it is clear that pneumatic wave energy conversion is a promising concept. With several hundred of these devices situated some 100 km off the coast of the Pacific Northwest each device would be producing from 50 to 200 kW which would be transferred back to shore.

  17. Pneumatic interactive gait rehabilitation orthosis: design and preliminary testing.

    PubMed

    Belforte, G; Eula, G; Appendino, S; Sirolli, S

    2011-02-01

    Motor rehabilitation techniques based on passive movement of the lower limbs have been developed over the past 15 years. Gait training automation is the latest innovation in these techniques. This paper describes the design and development of a pneumatic interactive gait rehabilitation orthosis (PIGRO), as well as the first experimental results obtained with healthy subjects. PIGRO consists of a modular and size-adaptable exoskeleton, pneumatic actuation systems for the six actuated degrees of freedom (DoF), and a control unit. The foot orthosis and ankle actuation can be removed and/or replaced with orthopaedic shoes so as to permit gait rehabilitation while advancing between parallel bars with ground contact and partial body weight support (i.e. not walking in place). Control logic provides closed-loop position control independently on each joint, with position feedback for each joint in real time. Imposed curves are physiological joint angles: it is also possible to choose between activating one or both legs and to modify curves to obtain different gait patterns if required. The paper concludes with a presentation of experimental results for the device's performance.

  18. Development of an air pneumatic suspension system for transtibial prostheses.

    PubMed

    Pirouzi, Gholamhossein; Abu Osman, Noor Azuan; Oshkour, Azim Ataollahi; Ali, Sadeeq; Gholizadeh, Hossein; Abas, Wan A B Wan

    2014-09-09

    The suspension system and socket fitting of artificial limbs have major roles and vital effects on the comfort, mobility, and satisfaction of amputees. This paper introduces a new pneumatic suspension system that overcomes the drawbacks of current suspension systems in donning and doffing, change in volume during daily activities, and pressure distribution in the socket-stump interface. An air pneumatic suspension system (APSS) for total-contact sockets was designed and developed. Pistoning and pressure distribution in the socket-stump interface were tested for the new APSS. More than 95% of the area between each prosthetic socket and liner was measured using a Tekscan F-Scan pressure measurement which has developed matrix-based pressure sensing systems. The variance in pressure around the stump was 8.76 kPa. APSS exhibits less pressure concentration around the stump, improved pressure distribution, easy donning and doffing, adjustability to remain fitted to the socket during daily activities, and more adaptability to the changes in stump volume. The volume changes were adjusted by utility of air pressure sensor. The vertical displacement point and reliability of suspension were assessed using a photographic method. The optimum pressure in every level of loading weight was 55 kPa, and the maximum displacement was 6 mm when 90 N of weight was loaded.

  19. Prognostics for Ground Support Systems: Case Study on Pneumatic Valves

    NASA Technical Reports Server (NTRS)

    Daigle, Matthew; Goebel, Kai

    2011-01-01

    Prognostics technologies determine the health (or damage) state of a component or sub-system, and make end of life (EOL) and remaining useful life (RUL) predictions. Such information enables system operators to make informed maintenance decisions and streamline operational and mission-level activities. We develop a model-based prognostics methodology for pneumatic valves used in ground support equipment for cryogenic propellant loading operations. These valves are used to control the flow of propellant, so failures may have a significant impact on launch availability. Therefore, correctly predicting when valves will fail enables timely maintenance that avoids launch delays and aborts. The approach utilizes mathematical models describing the underlying physics of valve degradation, and, employing the particle filtering algorithm for joint state-parameter estimation, determines the health state of the valve and the rate of damage progression, from which EOL and RUL predictions are made. We develop a prototype user interface for valve prognostics, and demonstrate the prognostics approach using historical pneumatic valve data from the Space Shuttle refueling system.

  20. Independence of biomechanical forces and craniofacial pneumatization in Cebus.

    PubMed

    Rae, Todd C; Koppe, Thomas

    2008-11-01

    Several different factors have been hypothesized as explanations of variation in primate paranasal sinus size. Biomechanical forces, particularly those associated with mastication, are frequently evoked to account for differences in primate craniofacial pneumatization. To test whether masticatory stresses are responsible for maxillary sinus volume diversity, two platyrrhine species of the genus Cebus (C. apella and C. albifrons) were examined. The former has been identified as a hard object feeder, and many morphological differences between the two species are attributable to differences in the mechanical properties of their respective diets. Sinus volumes were derived from serial coronal CT scans of the crania of adults. Several external cranial measurements were used to scale sinus volume relative to the size of the face. Relative measures of maxillary sinus volume were compared using standard statistical techniques. In all comparisons, the two capuchin species do not differ from one another significantly at P < 0.05. Thus, this "natural experiment" fails to support the interpretation that biomechanical forces acting on the facial skeleton substantially affect the degree of paranasal pneumatization in primates. This result suggests that it is unlikely that the maxillary sinus performs any function in relation to masticatory stress; other factors must be responsible for the variation in sinus volume among primates.

  1. Pneumatic oscillator circuits for timing and control of integrated microfluidics.

    PubMed

    Duncan, Philip N; Nguyen, Transon V; Hui, Elliot E

    2013-11-05

    Frequency references are fundamental to most digital systems, providing the basis for process synchronization, timing of outputs, and waveform synthesis. Recently, there has been growing interest in digital logic systems that are constructed out of microfluidics rather than electronics, as a possible means toward fully integrated laboratory-on-a-chip systems that do not require any external control apparatus. However, the full realization of this goal has not been possible due to the lack of on-chip frequency references, thus requiring timing signals to be provided from off-chip. Although microfluidic oscillators have been demonstrated, there have been no reported efforts to characterize, model, or optimize timing accuracy, which is the fundamental metric of a clock. Here, we report pneumatic ring oscillator circuits built from microfluidic valves and channels. Further, we present a compressible-flow analysis that differs fundamentally from conventional circuit theory, and we show the utility of this physically based model for the optimization of oscillator stability. Finally, we leverage microfluidic clocks to demonstrate circuits for the generation of phase-shifted waveforms, self-driving peristaltic pumps, and frequency division. Thus, pneumatic oscillators can serve as on-chip frequency references for microfluidic digital logic circuits. On-chip clocks and pumps both constitute critical building blocks on the path toward achieving autonomous laboratory-on-a-chip devices.

  2. Development of an Air Pneumatic Suspension System for Transtibial Prostheses

    PubMed Central

    Pirouzi, Gholamhossein; Osman, Noor Azuan Abu; Oshkour, Azim Ataollahi; Ali, Sadeeq; Gholizadeh, Hossein; Wan Abas, Wan A. B.

    2014-01-01

    The suspension system and socket fitting of artificial limbs have major roles and vital effects on the comfort, mobility, and satisfaction of amputees. This paper introduces a new pneumatic suspension system that overcomes the drawbacks of current suspension systems in donning and doffing, change in volume during daily activities, and pressure distribution in the socket-stump interface. An air pneumatic suspension system (APSS) for total-contact sockets was designed and developed. Pistoning and pressure distribution in the socket-stump interface were tested for the new APSS. More than 95% of the area between each prosthetic socket and liner was measured using a Tekscan F-Scan pressure measurement which has developed matrix-based pressure sensing systems. The variance in pressure around the stump was 8.76 kPa. APSS exhibits less pressure concentration around the stump, improved pressure distribution, easy donning and doffing, adjustability to remain fitted to the socket during daily activities, and more adaptability to the changes in stump volume. The volume changes were adjusted by utility of air pressure sensor. The vertical displacement point and reliability of suspension were assessed using a photographic method. The optimum pressure in every level of loading weight was 55 kPa, and the maximum displacement was 6 mm when 90 N of weight was loaded. PMID:25207872

  3. The influence of radiation therapy on subperiosteal hydroxyapatite implants in rabbits

    SciTech Connect

    Khateery, S.; Waite, P.D.; Lemons, J.E. )

    1991-07-01

    Granular hydroxyapatite (HA) was implanted into subperiosteal pockets along both the right and left proximal tibias of 12 adult New Zealand white rabbits. The left extremities of 10 rabbits served as controls, whereas the right sides were irradiated with 2,250 rad in three doses over 5 days. The animals were killed at 1-week intervals starting at 2 weeks postirradiation. One half of each site was evaluated using standard histologic techniques while the other half was examined as a nondecalcified section. The quantity and the quality of new bone formation was determined using a rating scale and histomorphometric digitization. The results of this 4-month study showed that the amount of new bone formation around the HA granules was significantly greater in the irradiated sites. The irradiation produced no deleterious effects on the implant or the surrounding tissue areas.

  4. [Food irradiation].

    PubMed

    Migdał, W

    1995-01-01

    A worldwide standard on food irradiation was adopted in 1983 by Codex Alimentarius Commission of the Joint Food Standard Programme of the Food and Agriculture Organization (FAO) of the United Nations and the World Health Organization (WHO). As a result, 41 countries have approved the use of irradiation for treating one or more food items and the number is increasing. Generally, irradiation is used to: food loses, food spoilage, disinfestation, safety and hygiene. The number of countries which use irradiation for processing food for commercial purposes has been increasing steadily from 19 in 1987 to 33 today. In the frames of the national programme on the application of irradiation for food preservation and hygienization an experimental plant for electron beam processing has been established in Institute of Nuclear Chemistry and Technology. The plant is equipped with a small research accelerator Pilot (19MeV, 1 kW) and an industrial unit Elektronika (10MeV, 10 kW). On the basis of the research there were performed at different scientific institutions in Poland, health authorities have issued permission for irradiation for: spices, garlic, onions, mushrooms, potatoes, dry mushrooms and vegetables.

  5. Tissue irradiator

    DOEpatents

    Hungate, F.P.; Riemath, W.F.; Bunnell, L.R.

    1975-12-16

    A tissue irradiator is provided for the in-vivo irradiation of body tissue. The irradiator comprises a radiation source material contained and completely encapsulated within vitreous carbon. An embodiment for use as an in- vivo blood irradiator comprises a cylindrical body having an axial bore therethrough. A radioisotope is contained within a first portion of vitreous carbon cylindrically surrounding the axial bore, and a containment portion of vitreous carbon surrounds the radioisotope containing portion, the two portions of vitreous carbon being integrally formed as a single unit. Connecting means are provided at each end of the cylindrical body to permit connections to blood- carrying vessels and to provide for passage of blood through the bore. In a preferred embodiment, the radioisotope is thulium-170 which is present in the irradiator in the form of thulium oxide. A method of producing the preferred blood irradiator is also provided, whereby nonradioactive thulium-169 is dispersed within a polyfurfuryl alcohol resin which is carbonized and fired to form the integral vitreous carbon body and the device is activated by neutron bombardment of the thulium-169 to produce the beta-emitting thulium-170.

  6. Dynamic Friction Performance of a Pneumatic Cylinder with Al2O3 Film on Cylinder Surface.

    PubMed

    Chang, Ho; Lan, Chou-Wei; Wang, Hao-Xian

    2015-11-01

    A friction force system is proposed for accurately measuring friction force and motion properties produced by reciprocating motion of piston in a pneumatic cylinder. In this study, the proposed system is used to measure the effects of lubricating greases of different viscosities on the friction properties of pneumatic cylinder, and improvement of stick-slip motion for the cylinder bore by anodizing processes. A servo motor-driven ball screw is used to drive the pneumatic cylinder to be tested and to measure the change in friction force of the pneumatic cylinder. Experimental results show, that under similar test conditions, the lubricating grease with viscosity VG100 is best suited for measuring reciprocating motion of the piston of pneumatic cylinder. The wear experiment showed that, in the Al2O3 film obtained at a preset voltage 40 V in the anodic process, the friction coefficient and hardness decreased by 55% and increased by 274% respectively, thus achieving a good tribology and wear resistance. Additionally, the amplitude variation in the friction force of the pneumatic cylinder wall that received the anodizing treatment was substantially reduced. Additionally, the stick-slip motion of the pneumatic cylinder during low-speed motion was substantially improved.

  7. Radiation Damage Study in Natural Zircon Using Neutrons Irradiation

    SciTech Connect

    Lwin, Maung Tin Moe; Amin, Yusoff Mohd.; Kassim, Hasan Abu; Mohamed, Abdul Aziz; Karim, Julia Abdul

    2011-03-30

    Changes of atomic displacements in crystalline structure of natural zircon (ZrSiO{sub 4}) can be studied by using neutron irradiation on the surface of zircon and compared the data from XRD measurements before and after irradiation. The results of neutron irradiation on natural zircon using Pneumatic Transfer System (PTS) at PUSPATI TRIGA Research Reactor in the Malaysian Nuclear Agency are discussed in this work. The reactor produces maximum thermal power output of 1 MWatt and the neutron flux of up to 1x10{sup 13} ncm{sup -2}s{sup -1}. From serial decay processes of uranium and thorium radionuclides in zircon crystalline structure, the emission of alpha particles can produce damage in terms of atomic displacements in zircon. Hence, zircon has been extensively studied as a possible candidate for immobilization of fission products and actinides.

  8. Efficient Method for Calculating Hydraulic Conductivity from Pneumatic Slug Tests

    NASA Astrophysics Data System (ADS)

    Peng, X.; Cheung, B.; Knappett, P. S.; Zhan, H.

    2014-12-01

    Pneumatic slug tests are widely used in characterizing the hydraulic conductivity of aquifers. In comparison to a manual slug test wherein the water level is measured using a water level tape, pneumatic slug tests are especially useful when the water level recovery is very fast (<10 sec) in a high hydraulic conductivity (K) aquifer (>10-4 m/s) and when the recovery is very slow (<10-7 m/s). The submerged pressure transducer monitors pressure changes at intervals of fractions of a second and for longer recoveries no personnel are required to make repeated measurements. A pneumatic slug test begins with pressurizing the well at the well head using an air pump followed by several minutes waiting for the pressure in the well to equalize with the pressure outside the well screen. In semi-confined settings this equalization may take >5 minutes. In lower K media it's not always feasible to wait until the well fully recovers before making the next replicate measurement. Therefore, it would greatly reduce the time needed to make replicate measurements if these waiting times could be reduced. Here we present a method using non-linear least squares regression on a portion of the recovery curve to simultaneously fit 3 parameters used to determine K from a slug tests using the Hvorslev method. The advantage of this approach is that waiting for the well to reach static head between replicate measurements is not required. This is because the regression fits static head (H) from the shape of only part the recovery curve. We compare the resulting K values from this new method to values obtained from manually measured static heads for triplicate measurements on 50 wells. The well's settings ranged from unconfined to semi-confined and K ranged from 10-3 to 10-5 m/s. The new method gave identical results. We performed the same comparison on a subset 16 wells using data collected in half the time, where only part of the recovery curves were measured before starting the next replicate

  9. Portal venous gas and cardiopulmonary arrest during pneumatic reduction of an ileocolic intussusception.

    PubMed

    Ryan, Mark L; Fields, Jonathan M; Sola, Juan E; Neville, Holly L

    2011-04-01

    We present the case of an 8-month-old infant with a small bowel obstruction secondary to an ileocolic intussusception without a pathologic lead point. During pneumatic reduction, the patient went into cardiopulmonary arrest, at which point portal venous gas (PVG) was visualized on radiography. Here we present-to our knowledge-the first reported case of PVG secondary to pneumatic reduction of an intussusception along with a review of the literature regarding known complications of pneumatic reduction and the etiologies of PVG.

  10. Irradiation subassembly

    DOEpatents

    Seim, O.S.; Filewicz, E.C.; Hutter, E.

    1973-10-23

    An irradiation subassembly for use in a nuclear reactor is described which includes a bundle of slender elongated irradiation -capsules or fuel elements enclosed by a coolant tube and having yieldable retaining liner between the irradiation capsules and the coolant tube. For a hexagonal bundle surrounded by a hexagonal tube the yieldable retaining liner may consist either of six segments corresponding to the six sides of the tube or three angular segments each corresponding in two adjacent sides of the tube. The sides of adjacent segments abut and are so cut that metal-tometal contact is retained when the volume enclosed by the retaining liner is varied and Springs are provided for urging the segments toward the center of the tube to hold the capsules in a closely packed configuration. (Official Gazette)

  11. The role of particle collisions in pneumatic transport

    NASA Astrophysics Data System (ADS)

    Mastorakos, E.; Louge, M.; Jenkins, J. T.

    1989-09-01

    A model of dilute gas-solid flow in vertical risers is developed in which the particle phase is treated as a granular material, the balance equations for rapid granular flow are modified to incorporate the drag force from the gas, and boundary conditions, based on collisional exchanges of momentum and energy at the wall, are employed. In this model, it is assumed that the particle fluctuations are determined by inter-particle collisions only and that the turbulence of the gas is unaffected by the presence of the particles. The model is developed in the context of, but not limited to, steady, fully developed flow. A numerical solution of the resulting governing equations provides concentration profiles generally observed in dilute pneumatic flow, velocity profiles in good agreement with the measurements of Tsuji, et al. (1984), and an explanation for the enhancement of turbulence that they observed.

  12. Pneumatic Micro Dispenser Chip for Portable Micro Analysis Devices

    NASA Astrophysics Data System (ADS)

    Hasegawa, Tadahiro; Tsuji, Toshiyuki; Ikuta, Koji

    The prototype of the pneumatic micro dispenser chip for portable micro analysis devices was developed successfully. This micro dispenser succeeded to divide liquid into 1µL without any dead volume by decompressing and the compressing air in only one micro pump. The dispensing operation is achieved by the original micro liquid detecting method and four hat-shaped check valves. The detecting method utilized the refraction of the infrared rays LED. Not only passage of the fluid into the channel but also its existence can be detected as TTL level signal. The hat-shaped silicone rubber valve which functions itself as a unidirectional passive valve was proposed. The check valve with low opening pressure (3kPa) and high inverse pressure (over 300kPa) was developed successfully. This micro dispenser chip is useful for portable micro analysis devices.

  13. A high performance pneumatic braking system for heavy vehicles

    NASA Astrophysics Data System (ADS)

    Miller, Jonathan I.; Cebon, David

    2010-12-01

    Current research into reducing actuator delays in pneumatic brake systems is opening the door for advanced anti-lock braking algorithms to be used on heavy goods vehicles. However, these algorithms require the knowledge of variables that are impractical to measure directly. This paper introduces a sliding mode braking force observer to support a sliding mode controller for air-braked heavy vehicles. The performance of the observer is examined through simulations and field testing of an articulated heavy vehicle. The observer operated robustly during single-wheel vehicle simulations, and provided reasonable estimates of surface friction from test data. The effect of brake gain errors on the controller and observer are illustrated, and a recursive least squares estimator is derived for the brake gain. The estimator converged within 0.3 s in simulations and vehicle trials.

  14. The role of particle collisions in pneumatic transport

    NASA Technical Reports Server (NTRS)

    Mastorakos, E.; Louge, M.; Jenkins, J. T.

    1989-01-01

    A model of dilute gas-solid flow in vertical risers is developed in which the particle phase is treated as a granular material, the balance equations for rapid granular flow are modified to incorporate the drag force from the gas, and boundary conditions, based on collisional exchanges of momentum and energy at the wall, are employed. In this model, it is assumed that the particle fluctuations are determined by inter-particle collisions only and that the turbulence of the gas is unaffected by the presence of the particles. The model is developed in the context of, but not limited to, steady, fully developed flow. A numerical solution of the resulting governing equations provides concentration profiles generally observed in dilute pneumatic flow, velocity profiles in good agreement with the measurements of Tsuji, et al. (1984), and an explanation for the enhancement of turbulence that they observed.

  15. Design of a biped robot actuated by pneumatic artificial muscles.

    PubMed

    Liu, Yixiang; Zang, Xizhe; Liu, Xinyu; Wang, Lin

    2015-01-01

    High compliant legs are essential for the efficient versatile locomotion and shock absorbency of humans. This study proposes a biped robot actuated by pneumatic artificial muscles to mimic human locomotion. On the basis of the musculoskeletal architecture of human lower limbs, each leg of the biped robot is modeled as a system of three segments, namely, hip joint, knee joint, and ankle joint, and eleven muscles, including both monoarticular and biarticular muscles. Each rotational joint is driven by a pair of antagonistic muscles, enabling joint compliance to be tuned by operating the pressure inside the muscles. Biarticular muscles play an important role in transferring power between joints. Walking simulations verify that biarticular muscles contribute to joint compliance and can absorb impact energy when the robot makes an impact upon ground contact.

  16. Preliminary measurements on heat balance in pneumatic tires

    NASA Technical Reports Server (NTRS)

    Nybakken, G. H.; Collart, D. Y.; Staples, R. J.; Lackey, J. I.; Clark, S. K.; Dodge, R. N.

    1973-01-01

    A variety of tests was undertaken to determine the nature of heat generation associated with a pneumatic tire operating under various conditions. Tests were conducted to determine the magnitude and distribution of internally generated heat caused by hysteresis in the rubber and ply fabric in an automobile tire operating under conditions of load, pressure, and velocity representative of normal operating conditions. These included tests at various yaw angles and tests with braking applied. In other tests, temperature sensors were mounted on a road to measure the effect of a tire rolling over and an attempt was made to deduce the magnitude and nature of interfacial friction from the resulting information. In addition, tests were performed using the scratch plate technique to determine the nature of the motion between the tire and road. Finally, a model tire was tested on a roadwheel, the surface covering which could be changed, and an optical pyrometer was used to measure rubber surface temperatures.

  17. Acute Radiation Hypotension in the Rabbit: a Model for the Human Radiation Shock Syndrome.

    NASA Astrophysics Data System (ADS)

    Makale, Milan Theodore

    This study has shown that total body irradiation (TBI) of immature (40 to 100 day old) rabbits leads to an acute fall in mean arterial pressure (MAP) 30 to 90 minutes after exposure, which takes no more than about three minutes, and often results in pressures which are less than 50% of the lowest pre-exposure MAP. This is termed acute cardiovascular collapse (ACC). ACC is often accompanied by ECG T-wave elevation, a sharp rise in ear temperature, labored breathing, pupillary constriction, bladder emptying, and loss of abdominal muscle tone. About 73% of 40 to 100 day rabbits exhibit ACC; the others and most older rabbits display gradual pressure reductions (deliberate hypotension) which may be profound, and which may be accompanied by the same changes associated with ACC. ACC and deliberate hypotension occurred in rabbits cannulated in the dorsal aorta, and in non-operated animals. The decline in MAP for all 40 to 100 day cannulated rabbits (deliberate and ACC responders) is 55.4%. The experiments described below only involved 40 to 100 day cannulated TBI rabbits. Heart region irradiation resulted in an average MAP decline of 29.1%, with 1/15 rabbits showing ACC. Heart shielding during TBI reduced the decline in MAP to 19%, with 1/10 rabbits experiencing ACC. These results imply that the heart region, which includes the heart, part of the lungs, neural receptors, roots of the systemic vessels, and the blood, is a sensitive target. Bilateral vagotomy reduced the decline in MAP to 24.9%, and abolished ACC. Atropine (6 mg/kg) reduced the frequency of ACC to 26%, and the decline in MAP to 41.4%. In 11/13 rabbits the voltage generated by left vagal transmission rose after TBI. The vagi appear to participate in radiation hypotension. Heart shielding together with bilateral vagotomy reduced the decline in MAP to only 9.9%, with no ACC responders. The mean right ventricular pressure (MRVP) rose after TBI in 8/10 rabbits. In animals which displayed either ACC or steep

  18. Analysis of nonlinear elastic behavior in miniature pneumatic artificial muscles

    NASA Astrophysics Data System (ADS)

    Hocking, Erica G.; Wereley, Norman M.

    2013-01-01

    Pneumatic artificial muscles (PAMs) are well known for their excellent actuator characteristics, including high specific work, specific power, and power density. Recent research has focused on miniaturizing this pneumatic actuator technology in order to develop PAMs for use in small-scale mechanical systems, such as those found in robotic or aerospace applications. The first step in implementing these miniature PAMs was to design and characterize the actuator. To that end, this study presents the manufacturing process, experimental characterization, and analytical modeling of PAMs with millimeter-scale diameters. A fabrication method was developed to consistently produce low-cost, high performance, miniature PAMs using commercially available materials. The quasi-static behavior of these PAMs was determined through experimentation on a single actuator with an active length of 39.16 mm (1.54 in) and a diameter of 4.13 mm (0.1625 in). Testing revealed the PAM’s full evolution of force with displacement for operating pressures ranging from 207 to 552 kPa (30-80 psi in 10 psi increments), as well as the blocked force and free contraction at each pressure. Three key nonlinear phenomena were observed: nonlinear PAM stiffness, hysteresis of the force versus displacement response for a given pressure, and a pressure deadband. To address the analysis of the nonlinear response of these miniature PAMs, a nonlinear stress versus strain model, a hysteresis model, and a pressure bias are introduced into a previously developed force balance analysis. Parameters of these nonlinear model refinements are identified from the measured force versus displacement data. This improved nonlinear force balance model is shown to capture the full actuation behavior of the miniature PAMs at each operating pressure and reconstruct miniature PAM response with much more accuracy than previously possible.

  19. Late effects from particulate radiations in primate and rabbit tissues

    NASA Technical Reports Server (NTRS)

    Lett, J. T.; Cox, A. B.; Bergtold, D. S.; Lee, A. C.; Pickering, J. E.

    1984-01-01

    In connection with studies regarding the hazards posed by ionizing radiations to man in space, the U.S. Air Force conducted an experiment about 20 years ago. In this experiment a large number of young rhesus monkeys was exposed to proton fluxes similar to those to be anticipated during solar flares. After irradiation, the animals were kept at the USAF School of Aerospace Medicine in Texas. The monkeys have been employed in investigations concerning aspects of late radiation damage. These investigations are discussed, taking into account the propagation of fibroblasts from irradiated monkeys. The results of the investigations are evaluated, giving attention also to experiments with white rabbits. It is found that, except in the case of major solar flares, when acute radiation damage could lead quickly to death, the hazards to astronauts from space radiations arise from such debilitating late effects as cataracts, damage to the central nervous system and benign tumors, and life-threatening neoplasia.

  20. HEREDITARY OSTEOPETROSIS OF THE RABBIT

    PubMed Central

    Pearce, Louise; Brown, Wade H.

    1948-01-01

    The manifestations and course of an hereditary disease of the rabbit are reported. The condition is present at birth and is invariably fatal, generally in the 4th and 5th weeks of age. Retardation and eventual cessation of growth with marked reduction in size are conspicuous characteristic symptoms. The condition, which first occurred in the backcross progeny of a pure bred Dutch male rabbit, is inherited. It is determined by the expression of a simple recessive unit factor, affected individuals being homozygous for the factor. Rabbits heterozygous for the factor are identified only by appropriate breeding tests. The condition is not sex-linked. The disease has a remarkable resemblance to osteopetrosis or marble bone disease of infants and children with respect to signs and general course and also, as may be stated in anticipation of later discussions (5, 6), to the characteristic abnormal condition of the skeleton. PMID:18103397

  1. European Rabbits as Reservoir for Coxiella burnetii

    PubMed Central

    González-Barrio, David; Maio, Elisa; Vieira-Pinto, Madalena

    2015-01-01

    We studied the role of European rabbits (Oryctolagus cuniculus) as a reservoir for Coxiella burnetii in the Iberian region. High individual and population seroprevalences observed in wild and farmed rabbits, evidence of systemic infections, and vaginal shedding support the reservoir role of the European rabbit for C. burnetii. PMID:25988670

  2. Application of Model-based Prognostics to a Pneumatic Valves Testbed

    NASA Technical Reports Server (NTRS)

    Daigle, Matthew; Kulkarni, Chetan S.; Gorospe, George

    2014-01-01

    Pneumatic-actuated valves play an important role in many applications, including cryogenic propellant loading for space operations. Model-based prognostics emphasizes the importance of a model that describes the nominal and faulty behavior of a system, and how faulty behavior progresses in time, causing the end of useful life of the system. We describe the construction of a testbed consisting of a pneumatic valve that allows the injection of faulty behavior and controllable fault progression. The valve opens discretely, and is controlled through a solenoid valve. Controllable leaks of pneumatic gas in the testbed are introduced through proportional valves, allowing the testing and validation of prognostics algorithms for pneumatic valves. A new valve prognostics approach is developed that estimates fault progression and predicts remaining life based only on valve timing measurements. Simulation experiments demonstrate and validate the approach.

  3. [The scintigraphic assessment of the patients suffering from cardia achalasia, treated by pneumatic dilatation].

    PubMed

    Stan, Mărioara; Bălan, G; Rusu, Maria; Ciortescu, Irina; Popa, Florentina

    2002-01-01

    The esophageal scintigraphy is a technique used to evaluate the motility and the clearance of the esophagus. The patients with achalasia of the cardia were evaluated, before treating them with pneumatic dilatation and after. The reason is to evaluate the efficiency of the pneumatic dilatation technique in the treatment of esophageal achalasia. The pneumatic dilatation with an instrument type Rigiflex is a well/handled and used technique in our clinic. In the study 22 patients were included and we had in view the esophageal transit time and the residuary radioactivity before and after the pneumatic dilatation. We established an important statistical improvement of the data obtained after the dilatation comparative with the data before the treatment (p < 0.01).

  4. An investigation of the effects of pneumatic actuator design on slip control for heavy vehicles

    NASA Astrophysics Data System (ADS)

    Miller, Jonathan I.; Cebon, David

    2013-01-01

    Progress in reducing actuator delays in pneumatic brake systems is opening the door for advanced anti-lock braking algorithms to be used on heavy goods vehicles. However, little has been published on slip controllers for air-braked heavy vehicles, or the effects of slow pneumatic actuation on their design and performance. This paper introduces a sliding mode slip controller for air-braked heavy vehicles. The effects of pneumatic actuator delays and flow rates on stopping performance and air (energy) consumption are presented through vehicle simulations. Finally, the simulations are validated with experiments using a hardware-in-the-loop rig. It is shown that for each wheel, pneumatic valves with delays smaller than 3 ms and orifice diameters around 8 mm provide the best performance.

  5. Pattern design of a non-pneumatic tyre for stiffness using topology optimization

    NASA Astrophysics Data System (ADS)

    Gwun Jang, In; Sung, Young Hwa; Jong Yoo, Eui; Kwak, Byung Man

    2012-02-01

    Non-pneumatic tyres have been developed and are being investigated, but are not very prevalent. Many design studies are still needed from the viewpoint of material, pattern, and structures. However, no systematic research for such important design issues has been reported in the literature up to now. In this article, topology optimization was utilized to determine optimal topological patterns of non-pneumatic tyres in the design process, with the goal of matching the static stiffness of the current pneumatic tyres. Under this optimization formulation with weighted compliance and a volume constraint, several different patterns were obtained depending on the number of sections, volume fraction, and weighting factors. Among them, three representative patterns were chosen and analysed for possible applications under working conditions. This article proposes a systematic and efficient tool for designing the topological patterns of non-pneumatic tyres.

  6. Irradiated foods

    MedlinePlus

    ... it reduces the risk of food poisoning . Food irradiation is used in many countries. It was first approved in the U.S. to prevent sprouts on white potatoes, and to control insects on wheat and in certain spices and seasonings.

  7. Costs and benefits of pneumatic collection in three specific New York City cases

    SciTech Connect

    Miller, Benjamin; Spertus, Juliette; Kamga, Camille

    2014-11-15

    Highlights: • Pneumatic and truck collection were compared in three New York City locations. • Relative costs, energy use, and greenhouse gas emissions varied significantly. • Variations were due to location-specific factors (e.g., route density, truck type). • Under appropriate conditions, pneumatic collection reduces TMT, BTU, and GHG. • Pneumatic capex may be offset by operating savings and externality benefits. - Abstract: Truck-based collection of municipal solid waste imposes significant negative externalities on cities and constrains the efficiency of separate collection of recyclables and organics and of unit-price-based waste-reduction systems. In recent decades, hundreds of municipal-scale pneumatic collection systems have been installed in Europe and Asia. Relatively few prior studies have compared the economic or environmental impacts of these systems to those of truck collection. A critical factor to consider when making this comparison is the extent to which the findings reflect the specific geographic, demographic, and operational characteristics of the systems considered. This paper is based on three case studies that consider the specific characteristics of three locations, comparing pneumatic systems with conventional collection on the basis of actual waste tonnages, composition, sources, collection routes, truck trips, and facility locations. In one case, alternative upgrades to an existing pneumatic system are compared to a potential truck-collection operation. In the other cases, existing truck operations are compared to proposed pneumatic systems which, to reduce capital costs, would be installed without new trenching or tunneling through the use of existing linear infrastructure. For the two proposed retrofit pneumatic systems, up to 48,000 truck kilometers travelled would be avoided and energy use would be reduced by up to 60% at an incremental cost of up to $400,000 USD per year over the total operating-plus-capital cost of

  8. Experimental study on wavy-flow pneumatic conveying in horizontal pipe

    NASA Astrophysics Data System (ADS)

    Xu, Hua; Liu, Shi; Wang, Haigang; Jiang, Fan

    2002-05-01

    Low-velocity pneumatic conveying systems have been developed to meet the requirement of low operation costs and have been widely used in chemical and process industries. However, the understanding of the mechanism is limited. This paper reports an experimental study on a slug-flow pneumatic conveying. Electrical capacitance tomography has been used to visualize plug shape and identify the flow pattern. Comparison was made between the experimental data of pressure drop with existed models.

  9. Costs and benefits of pneumatic collection in three specific New York City cases.

    PubMed

    Miller, Benjamin; Spertus, Juliette; Kamga, Camille

    2014-11-01

    Truck-based collection of municipal solid waste imposes significant negative externalities on cities and constrains the efficiency of separate collection of recyclables and organics and of unit-price-based waste-reduction systems. In recent decades, hundreds of municipal-scale pneumatic collection systems have been installed in Europe and Asia. Relatively few prior studies have compared the economic or environmental impacts of these systems to those of truck collection. A critical factor to consider when making this comparison is the extent to which the findings reflect the specific geographic, demographic, and operational characteristics of the systems considered. This paper is based on three case studies that consider the specific characteristics of three locations, comparing pneumatic systems with conventional collection on the basis of actual waste tonnages, composition, sources, collection routes, truck trips, and facility locations. In one case, alternative upgrades to an existing pneumatic system are compared to a potential truck-collection operation. In the other cases, existing truck operations are compared to proposed pneumatic systems which, to reduce capital costs, would be installed without new trenching or tunneling through the use of existing linear infrastructure. For the two proposed retrofit pneumatic systems, up to 48,000 truck kilometers travelled would be avoided and energy use would be reduced by up to 60% at an incremental cost of up to $400,000 USD per year over the total operating-plus-capital cost of conventional collection. In the location where a greenfield pneumatic system is already in operation, truck collection would be both less expensive and more energy-efficient than pneumatic collection. The results demonstrate that local geographic, demographic, and operational conditions play a decisive role in determining whether pneumatic collection will reduce energy requirements, produce more or fewer greenhouse gas emissions, and cost more

  10. Intermittent pneumatic compression of legs increases microcirculation in distant skeletal muscle.

    PubMed

    Liu, K; Chen, L E; Seaber, A V; Johnson, G W; Urbaniak, J R

    1999-01-01

    Intermittent pneumatic compression has been established as a method of clinically preventing deep vein thrombosis, but the mechanism has not been documented. This study observed the effects of intermittent pneumatic compression of legs on the microcirculation of distant skeletal muscle. The cremaster muscles of 80 male rats were exposed, a specially designed intermittent pneumatic-compression device was applied to both legs for 60 minutes, and the microcirculation of the muscles was assessed by measurement of the vessel diameter in three categories (10-20, 21-40, and 41-70 microm) for 120 minutes. The results showed significant vasodilation in arterial and venous vessels during the application of intermittent pneumatic compression, which disappeared after termination of the compression. The vasodilation reached a maximum 30 minutes after initiation of the compression and could be completely blocked by an inhibitor of nitric oxide synthase, NG-monomethyl-L-arginine (10 micromol/min). A 120-minute infusion of NG-monomethyl-L-arginine, beginning coincident with 60 minutes of intermittent pneumatic compression, resulted in a significant decrease in arterial diameter that remained at almost the same level after termination of the compression. The magnitude of the decrease in diameter in the group treated with intermittent pneumatic compression and NG-monomethyl-L-arginine was comparable with that in the group treated with NG-monomethyl-L-arginine alone. The results imply that the production of nitric oxide is involved in the positive influence of intermittent pneumatic compression on circulation. It is postulated that the rapid increase in venous velocity induced by intermittent pneumatic compression produces strong shear stress on the vascular endothelium, which stimulates an increased release of nitric oxide and thereby causes systemic vasodilation.

  11. Field and numerical determinations of pneumatic flow parameters of unsaturated fractured porous rocks on various scales

    NASA Astrophysics Data System (ADS)

    Guillon, S.; Vu, M. T.; Pili, E.; Adler, P. M.

    2013-05-01

    Air permeability is measured in the fractured crystalline rocks of the Roselend Natural Laboratory (France). Single-hole pneumatic injection tests as well as differential barometric pressure monitoring are conducted on scales ranging from 1 to 50 m, in both shallow and deep boreholes, as well as in an isolated 60 m3 chamber at 55 m depth. The field experiments are interpreted using numerical simulations in equivalent homogeneous porous media with their real 3-D geometry in order to estimate pneumatic parameters. For pneumatic injection tests, steady-state data first allow to estimate air permeability. Then, pressure recovery after a pneumatic injection test allows to estimate the air-filled porosity. Comparison between the various studied cases clarifies the influence of the boundary conditions on the accuracy of the often used 1-D estimate of air permeability. It also shows that permeabilities correlate slightly with fracture density. In the chamber, a 1 order-of-magnitude difference is found between the air permeabilities obtained from pneumatic injection tests and from differential barometric pressure monitoring. This discrepancy is interpreted as a scale effect resulting from the approximation of the heterogeneous fractured rock by a homogeneous numerical model. The difference between the rock volumes investigated by pneumatic injection tests and by differential barometric pressure monitoring may also play a role. No clear dependence of air permeability on saturation has been found so far.

  12. [The forensic medical characteristics of the entrance bullet holes created by the shots from pneumatic rifles].

    PubMed

    Legin, G A; Bondarchuk, A O; Perebetiuk, A N

    2015-01-01

    The objective of the present study was to compare the injurious action of three types of the bullets for the pneumatic weapons shot from different distances using the Gamo pump air pistol and the BAM B22-1 pneumatic rifle. The following four kinds of the bullets were tested: "the fireball", "Luman cap 0.3", "Luman Field Target 0.68" and "DIABOLO". It was experimentally shown that the injurious action of the bullets fired from the same distance from the pneumatic weapons depends on the type of both the bullet and the weapon, as well as the properties of the target material. Specifically, the action of bullets fired from the piston pneumatic rifle remained stable whereas that of the bullets shot from the gas-balloon air pistol decreased as the gas was exhausted. The studies by the contact-diffusion method have demonstrated that the entrance bullet holes created by the shots from pneumatic weapons are surrounded by dispersed metal particles which makes it possible to estimate the shooting distance. Moreover, the bullets fired from the pneumatic weapons leave the muzzle face imprint on certain target materials.

  13. Antibody immobilization using pneumatic spray: comparison with the avidin-biotin bridge immobilization method.

    PubMed

    Figueroa, Jhon; Magaña, Sonia; Lim, Daniel V; Schlaf, Rudy

    2012-12-14

    The formation of a thin antibody film on a glass surface using pneumatic spray was investigated as a potential immobilization technique for capturing pathogenic targets. Goat-Escherichia coli O157:H7 IgG films were made by pneumatic spray and compared against the avidin-biotin bridge immobilized films by assaying with green fluorescent protein (GFP) transformed E. coli O157:H7 cells and fluorescent reporter antibodies. Functionality, stability, and immobilization of the films were tested. The pneumatic spray films had lower fluorescence intensity values than the avidin-biotin bridge films but resulted in similar detection for E. coli O157:H7 at 10(5)-10(7)cells/ml sample concentrations with no detection of non-E. coli O157:H7 strains. Both methods also resulted in similar percent capture efficiencies. The results demonstrated that immobilization of antibody via pneumatic spray did not render the antibody non-functional and produced stable antibody films. The amount of time necessary for immobilization of the antibody was reduced significantly from 24h for the avidin-biotin bridge to 7 min using the pneumatic spray technique, with additional benefits of greatly reduced use of materials and chemicals. The pneumatic spray technique promises to be an alternative for the immobilization of antibodies on glass slides for capturing pathogenic targets and use in biosensor type devices.

  14. Pneumatic motor powered Thrust Vector Control (TVC) for liquid propelled launch vehicles

    NASA Astrophysics Data System (ADS)

    Malone, Mark C.; Evans, P. S.

    1992-02-01

    Recent studies performed for the Titan 4 launch vehicle indicate significant potential advantages in replacing the current stage 1 and 2 recirculating hydraulic TVC (thrust vector control) system with a PMA (pneumatic mechanical actuation) system. Some of the advantages of a PMA system over the recirculating hydraulic system include reduced part count and weight, reduced maintenance and life-cycle cost, and improved mission reliability. PMA technology, used in aircraft applications since the 1960s, is well suited in launch vehicle TVC applications where an existing pneumatic pressure source is available. A typical pneumatic motor TVC consists of a pneumatic power source, a dual rotor pneumatic motor, a gear box, a ball screw actuator, and the associated closed-loop servo-control elements. One key issue with implementing this mechanical approach is designing a TVC system to withstand large load transient disturbances during liquid engine starting. Hydraulic actuator transient loads have exceeded 60,000 lb(sub f) for a 30,000 lb(sub f) stall design actuator during ground starts of the Titan 3B, Stage 1 engine. A PMA TVC system must also withstand these start transients without imparting excessive reaction loads to the engine nozzle and thrust structure. Work completed to date with Martin Marietta to examine pneumatic motor powered TVC options and technology benefits is presented. The load transient issue is discussed along with potential solutions and the associated trades. General background on PMA technology and experience base is also presented.

  15. Lymphocyte lifetime in the rabbit measured by the decline in radiation-induced chromosome damage.

    PubMed

    Decat, G; Leonard, A

    1980-08-01

    The life span of rabbit lymphocytes carrying radiation-induced chromosome aberrations has been studied by following the decline in aberration frequency as a function of the time after irradiation. Female rabbits were given a whole body X-ray dose of 300 rad. The day before exposure and at 2 hours, 14, 28, 42, 56, 84, 140, 250 and 500 days thereafter, blood samples were taken from a marginal ear vein of each animal. A plot of log abnormalities against time suggests an exponential decline for dicentrics and fragments up to 140 days, the half time for dicentrics and fragments being 70 and 46 days respectively. The results of the present investigation thus demonstrate that because of their shorter life span, in vivo observations on aberrations in rabbit lymphocytes are not suitable for extrapolation of information on chronic exposure to man.

  16. Scleral Cross-linking Using Riboflavin and Ultraviolet-A Radiation for Prevention of Axial Myopia in a Rabbit Model.

    PubMed

    Dotan, Assaf; Kremer, Israel; Gal-Or, Orly; Livnat, Tami; Zigler, Arie; Bourla, Dan; Weinberger, Dov

    2016-04-03

    Myopic individuals, especially those with severe myopia, are at higher-than-normal risk of cataract, glaucoma, retinal detachment and chorioretinal abnormalities. In addition, pathological myopia is a common irreversible cause of visual impairment and blindness. Our study demonstrates the effect of scleral crosslinking using riboflavin and ultraviolet-A radiation on the development of axial myopia in a rabbit model. The axial length of the eyeball was measured by A-scan ultrasound in New Zealand white rabbits aged 13 days (male and female). The eye then underwent 360° conjunctival peritomy with scleral crosslinking, followed by tarsorrhaphy. Axial elongation was induced in 13 day-old New Zealand rabbits by suturing their right eye eyelids (tarsorrhaphy). The eyes were divided into quadrants, and every quadrant had two scleral irradiation zones, each with an area of 0.2 cm² and a radius of 4 mm. Crosslinking was performed by dropping 0.1% dextran-free riboflavin-5-phosphate onto the irradiation zones 20 sec before ultraviolet-A irradiation and every 20 sec during the 200 sec irradiation time. UVA radiation (370 nm) was applied perpendicular to the sclera at 57 mW/cm² (total UVA light dose, 57 J/cm²). Tarsorrhaphies were removed on day 55, followed by repeated axial length measurements. This study demonstrates that scleral crosslinking with riboflavin and ultraviolet-A radiation effectively prevents occlusion-induced axial elongation in a rabbit model.

  17. Effects of X radiation on the retina of the albino rabbit as viewed with the scanning electron microscope

    SciTech Connect

    Newton, J.C.; Barsa-Newton, M.C.; Wardly, J.

    1980-02-01

    The eyes of albino rabbits were exposed in vivo to 7000 rad of X radiation, and the retinas were examined with a scanning electron microscope 24 and 72 h after irradiation. The rods and cones of the retina were observed to show the most severe damage.

  18. The effect of low level laser on condylar growth during mandibular advancement in rabbits

    PubMed Central

    2012-01-01

    Introduction It has been shown that Low Level Laser (LLL) has a positive effect on bone formation. The aim of this study was to evaluate the effect of low level laser on condylar growth during mandibular advancement in rabbits. Materials and methods Continuous forward mandibular advancement was performed in fourteen male Albino rabbits with the mean age of 8 weeks and the mean weight of 1.5 ± 0.5 kg, with acrylic inclined planes. The rabbits were randomly assigned into two groups after 4 weeks. LLL (KLO3: wave length 630 nm) was irradiated at 3 points around the TMJ, through the skin in the first group. The exposure was performed for 3 minutes at each point (a total of 9 minutes) once a day for 3 weeks. The control group was not exposed to any irradiation. The rabbits in both groups were sacrificed after two months and the histological evaluation of TMJ was performed to compare fibrous tissue, cartilage, and new bone formation in condylar region in both groups. Disc displacement was also detected in both groups. Student's t-test, Exact Fisher and Chi square tests were used for the statistical analysis. Results The formation of fibrous tissue was significantly lower, while bone formation was significantly greater in lased group as compared with control group. The thickness of cartilage did not differ significantly between two groups. Conclusion Irradiation of LLL (KLO3) during mandibular advancement in rabbits, increases bone formation in condylar region, while neither increase in the cartilage thickness nor fibrous tissues was observed. PMID:22361310

  19. Microbiological quality of rabbit meat.

    PubMed

    Rodríguez-Calleja, Jose M; Santos, Jesús A; Otero, Andrés; García-López, María-Luisa

    2004-05-01

    World rabbit meat production is estimated to be over 1 million tons, and Spain is the third largest producer. Although rabbit meat is marketed and consumed worldwide, information on microbiological quality is very scarce. Here, we report indicator organisms, spoilage flora, sensory quality, and some physicochemical traits of 24 h postmortem chilled rabbit carcasses and prepackaged rabbit meat stored chilled in air for 0 to 3 days at the retail level. The mean total bacterial count (4.01 +/- 0.48 log CFU/g) for carcasses dressed at a small abattoir by a manual process was significantly lower (P < 0.05) than that (4.96 +/- 0.90 log CFU/g) for carcasses dressed at a large abattoir in automated slaughter lines. Both groups of carcasses had mean pH values of 5.98. The dominant contaminants on carcasses from the small abattoir were Pseudomonas, lactic acid bacteria, and yeasts. These microorganisms and Brochothrix thermosphacta were dominant on carcasses from the large abattoir. On prepacked hind legs (pH 6.26 +/- 0.18) stored at -1 to +1 degree C (supermarket 1), mean aerobic mesophilic count was 5.87 +/- 1.03 log CFU/g, and the major microbial groups were Pseudomonas, yeasts, lactic acid bacteria, and B. thermosphacta. On prepacked whole carcasses (pH 6.37 +/- 0.18) displayed at -1 to +5 degrees C (supermarket 2), mean aerobic mesophilic count was 6.60 +/- 1.18 and the same microbial groups were dominant. Relative Escherichia coli incidence was supermarket 2 > large abattoir > supermarket 1 > small abattoir. Overall, low numbers of coliforms, Enterobacteriaceae, psychrotrophic clostridia, coagulase-positive staphylococci, and molds were found. Sensory scores, pH values, and L-lactic acid content differentiated fresh carcasses from retail samples. Data obtained suggest that the microflora of chilled rabbit meat are different from those found on the meat of other animals.

  20. Pneumatic artificial muscle actuators for compliant robotic manipulators

    NASA Astrophysics Data System (ADS)

    Robinson, Ryan Michael

    Robotic systems are increasingly being utilized in applications that require interaction with humans. In order to enable safe physical human-robot interaction, light weight and compliant manipulation are desirable. These requirements are problematic for many conventional actuation systems, which are often heavy, and typically use high stiffness to achieve high performance, leading to large impact forces upon collision. However, pneumatic artificial muscles (PAMs) are actuators that can satisfy these safety requirements while offering power-to-weight ratios comparable to those of conventional actuators. PAMs are extremely lightweight actuators that produce force in response to pressurization. These muscles demonstrate natural compliance, but have a nonlinear force-contraction profile that complicates modeling and control. This body of research presents solutions to the challenges associated with the implementation of PAMs as actuators in robotic manipulators, particularly with regard to modeling, design, and control. An existing PAM force balance model was modified to incorporate elliptic end geometry and a hyper-elastic constitutive relationship, dramatically improving predictions of PAM behavior at high contraction. Utilizing this improved model, two proof-of-concept PAM-driven manipulators were designed and constructed; design features included parallel placement of actuators and a tendon-link joint design. Genetic algorithm search heuristics were employed to determine an optimal joint geometry; allowing a manipulator to achieve a desired torque profile while minimizing the required PAM pressure. Performance of the manipulators was evaluated in both simulation and experiment employing various linear and nonlinear control strategies. These included output feedback techniques, such as proportional-integral-derivative (PID) and fuzzy logic, a model-based control for computed torque, and more advanced controllers, such as sliding mode, adaptive sliding mode, and

  1. Effectiveness of Thermal-Pneumatic Airfoil-Ice-Protection System

    NASA Technical Reports Server (NTRS)

    Gowan, William H., Jr.; Mulholland, Donald R.

    1951-01-01

    Icing and drag investigations were conducted in the NACA Lewis icing research tunnel employing a combination thermal-pneumatic de-icer mounted on a 42-inch-chord NACA 0018 airfoil. The de-icer consisted of a 3-inch-wide electrically heated strip symmetrically located about the leading edge with inflatable tubes on the upper and lower airfoil surfaces aft of the heated area. The entire de-icer extended to approximately 25 percent of chord. A maximum power density of 9.25 watts per square inch was required for marginal ice protection on the airfoil leading edge at an air temperature of 00 F and an airspeed of 300 miles per hour. Drag measurements indicated, that without icing, the de-icer installation increased the section drag to approximately 140 percent of that of the bare airfoil; with the tubes inflated, this value increased to a maximum of approximately 620 percent. A 2-minute tube-inflation cycle prevented excessive ice formation on the inflatable area although small scattered residual Ice formations remained after inflation and were removed intermittently during later cycles. Effects of the time lag of heater temperatures after initial application of power and the insulating effect of ice formations on heater temperatures were also determined.

  2. An electromagnetic microvalve for pneumatic control of microfluidic systems.

    PubMed

    Liu, Xuling; Li, Songjing

    2014-10-01

    An electromagnetic microvalve for pneumatic control of microfluidic devices has been designed, fabricated, and tested. The microvalve is composed of two parts: a miniature electromagnetic actuator and a valve body. The electromagnetic actuator consists mainly of a thin polydimethylsiloxane (PDMS)-based elastomer, which acts as the valve diaphragm. The diaphragm, used as a solid hydraulic medium, converts the large contact area of a valve core into a small contact area of valve head while maintaining a large stroking force. This microvalve remains closed because of a compressed mechanical spring force generated by the actuator. On the other hand, when a voltage is applied, the valve core moves up, relaxing the thin PDMS membrane, opening the microvalve. The fast open response (~17 ms) of the valve was achieved with a leak rate as low as 0.026 sccm at 200 KPa (N2) pressure. We tested the pertinent dynamic parameters such as flow rate in on/off mode, flow rate of duty cycles, and actuated frequencies in pulse width modulation (PWM) mode. Our method provides a simple, cheap, and small microvalve that avoids the bulky and expensive external pressure control solenoid manifold. This allows it to be easily integrated into portable and disposable devices.

  3. [Endoscopic sclerosis with pneumatic distension for pyriform sinus fistula treatment].

    PubMed

    Sanchís Blanco, G; Gutiérrez San Román, C; Bordallo Vázquez, M; Cortés Sáez, J; Barrios Fontoba, J E; Lluna González, J; Esteban Ricós, M J; Vila Carbó, J J

    2014-01-01

    Classic treatment for pyriform sinus fistula (PSF) has been surgical excision; however, less invasive therapeutic alternatives whose aim is the obliteration of the sinus have been described subsequently. The authors present a technical modification of endoscopic sclerosis with diathermy (ESD): continuous infusion of air flow through the flexible endoscope was used to distend the pyriform sinus and facilitate recognition of the fistula opening. The sinus obliteration was performed with a wire guide and diathermy. In the last 15 years, 9 patients were diagnosed of suffering from PSF in our institution. Initial treatment was antibiotics therapy associated in some cases to cervical abscess drainage. Fistulectomy was performed in 4 cases and ESD in 4. The ninth patient received both treatments, performing electrocauterization after a surgical recurrence. Three of the patients who underwent surgery relapsed; none treated by ESD did, or had any complications. In our experience, endoscopic sclerosis with pneumatic distension is a simple technique, reproducible, not invasive and very effective; hence we consider it might become a first line therapy for PSF.

  4. Prediction and Reduction of Noise in Pneumatic Bleed Valves

    NASA Astrophysics Data System (ADS)

    Taghavi Nezhad, Shervin

    This study investigates numerically the fluid mechanics and acoustics of pneumatic bleed valves used in turbofan engines. The goal is to characterized the fundamental processes of noise generation and devise strategies for noise reduction. Three different methods are employed for both analysis and redesign of the bleed valve to reduce noise. The bleed valve noise problem is carefully divided into multiple smaller problems. For large separations and tonal noises, the unsteady Reynolds-Averaged Navier-Stokes (URANS) method is utilized. This method is also applied in the re-designing of the bleed valve geometry. For the bleed valve muffler, which is comprised of perforated plates and a honeycomb, a Reynolds-Averaged Navier-Stokes (RANS) method combined with a simplified acoustic analogy is used. The original muffler design is modified to improve noise attenuation. Finally, for sound scattering through perforated plates, a fully implicit linearized Euler solver is developed. The problem of sound interaction with perforated plates is studied from two perspectives. In the first study the effect of high--speed mean flow is considered and it is shown that at Strouhal numbers of around 0.2-0.25 there is an increase in transmitted incident sound. In the second part, the interaction of holes in two--dimensional perforated plates is investigated using three different configurations. The study demonstrates that the hole interaction has a significant impact on sound attenuation, especially at high frequencies.

  5. Variable recruitment in bundles of miniature pneumatic artificial muscles.

    PubMed

    DeLaHunt, Sylvie A; Pillsbury, Thomas E; Wereley, Norman M

    2016-09-13

    The natural compliance and force generation properties of pneumatic artificial muscles (PAMs) allow them to operate like human muscles in anthropomorphic robotic manipulators. Traditionally, manipulators use a single PAM or multiple PAMs actuated in unison in place of a human muscle. However, these standard manipulators can experience significant efficiency losses when operated outside their target performance ranges at low actuation pressures. This study considers the application of a variable recruitment control strategy to a parallel bundle of miniature PAMs as an attempt to mimic the selective recruitment of motor units in a human muscle. Bundles of miniature PAMs are experimentally characterized, their actuation behavior is modeled, and the efficiency gains and losses associated with the application of a variable recruitment control strategy are assessed. This bio-inspired control strategy allows muscle bundles to operate the fewest miniature PAMs necessary to achieve a desired performance objective, improving the muscle bundle's operating efficiency over larger ranges of force generation and displacement. The study also highlights the need for improved PAM fabrication techniques to facilitate the production of identical miniature PAMs for inclusion in muscle bundles.

  6. Observations of ''granular jump'' in the pneumatic conveying system

    SciTech Connect

    Jaworski, Artur J.; Dyakowski, Tomasz

    2007-08-15

    This paper presents a preliminary study of a previously unreported phenomenon of the ''gas driven granular jump'', observed in the gas-solids flow within the pneumatic conveying system. From the phenomenological point of view, it resembles the already known processes such as hydraulic jumps in shallow water or granular jumps in granular flows in chutes or avalanches (although it seems most appropriate to explain it by analogy to a propagating granular bore). Clearly, unlike in classical phenomena of this type, the flow itself is driven by the aerodynamic forces related to the gas flow and the behaviour of the front of the ''jump'' is modified significantly by their presence. A series of high-speed camera visualisations are presented, which focus on this unusual behaviour of the flow on the border-line between cluster and stratified flow regimes in a horizontal pipe. Some similarities are drawn between the observed phenomenon and the broader class of problems exhibiting transition between super- and sub-critical flows. The fluid dynamical aspects and possible mechanisms behind the new phenomenon are discussed and the results obtained are compared quantitatively with simple theoretical models. (author)

  7. Abdominal Palpation Haptic Device for Colonoscopy Simulation Using Pneumatic Control.

    PubMed

    Cheng, M; Marinovic, W; Watson, M; Ourselin, S; Passenger, J; De Visser, H; Salvado, O; Riek, S

    2012-01-01

    In this paper, we describe the development of a haptic device to be used in a simulator aiming to train the skills of gastroenterology assistants in abdominal palpation during colonoscopy, as well as to train team interaction skills for the colonoscopy team. To understand the haptic feedback forces to be simulated by the haptic device, we conducted an experiment with five participants of varying BMI. The applied forces and displacements were measured and hysteresis modeling was used to characterize the experimental data. These models were used to determine the haptic feedback forces required to simulate a BMI case in response to the real-time user interactions. The pneumatic haptic device consisted of a sphygmomanometer bladder as the haptic interface and a fuzzy controller to regulate the bladder pressure. The haptic device showed good steady state and dynamic response was adequate for simulating haptic interactions. Tracking accuracy averaged 94.2 percent within 300 ms of the reference input while the user was actively applying abdominal palpation and minor repositioning.

  8. MRI-Compatible Pneumatic Robot for Transperineal Prostate Needle Placement

    PubMed Central

    Fischer, Gregory S.; Iordachita, Iulian; Csoma, Csaba; Tokuda, Junichi; DiMaio, Simon P.; Tempany, Clare M.; Hata, Nobuhiko; Fichtinger, Gabor

    2010-01-01

    Magnetic resonance imaging (MRI) can provide high-quality 3-D visualization of prostate and surrounding tissue, thus granting potential to be a superior medical imaging modality for guiding and monitoring prostatic interventions. However, the benefits cannot be readily harnessed for interventional procedures due to difficulties that surround the use of high-field (1.5T or greater) MRI. The inability to use conventional mechatronics and the confined physical space makes it extremely challenging to access the patient. We have designed a robotic assistant system that overcomes these difficulties and promises safe and reliable intraprostatic needle placement inside closed high-field MRI scanners. MRI compatibility of the robot has been evaluated under 3T MRI using standard prostate imaging sequences and average SNR loss is limited to 5%. Needle alignment accuracy of the robot under servo pneumatic control is better than 0.94 mm rms per axis. The complete system workflow has been evaluated in phantom studies with accurate visualization and targeting of five out of five 1 cm targets. The paper explains the robot mechanism and controller design, the system integration, and presents results of preliminary evaluation of the system. PMID:21057608

  9. Portable pneumatic biventricular driver for the Thoratec ventricular assist device.

    PubMed

    Farrar, D J; Buck, K E; Coulter, J H; Kupa, E J

    1997-01-01

    As patients with left ventricular (LVAD) and biventricular assist devices are supported for increasingly long durations while awaiting heart transplantation or cardiac recovery, there is a need to facilitate greater patient mobility and ambulation. To meet these needs, the authors have developed the Thoratec TLC-II Portable VAD Driver, which is a small brief-case sized (33 x 34 x 13 cm) pneumatic unit for Thoratec's paracorporeal and implantable VADs. The TLC-II consists of an electric motor driven air compressor for supplying both positive and negative air pressure, solenoid valves for switching between LVAD/RVAD filling and ejection, and microcontroller based electronics and firmware. Four power sources are provided: external power, two rechargeable lithium-ion battery packs, and an emergency battery that drives an independent electronic back-up system. The 8 kg TLC-II can be carried by hand, with a shoulder strap, or pushed on a wheeled mobility cart. Trend information stored in the TLC-II can be accessed by an external system computer with a color touchscreen mounted on a docking station, which also houses the battery charger. Control configurations (univentricular/biventricular operation, beat rates, etc.) are entered on the touchscreen and programmed into the TLC-II. In vitro testing demonstrates the ability to pump VAD outputs up to 7 L/min. By providing improved patient mobility, this small driver will enhance rehabilitation and improve the quality of life of VAD patients.

  10. MRI-Compatible Pneumatic Robot for Transperineal Prostate Needle Placement.

    PubMed

    Fischer, Gregory S; Iordachita, Iulian; Csoma, Csaba; Tokuda, Junichi; Dimaio, Simon P; Tempany, Clare M; Hata, Nobuhiko; Fichtinger, Gabor

    2008-06-01

    Magnetic resonance imaging (MRI) can provide high-quality 3-D visualization of prostate and surrounding tissue, thus granting potential to be a superior medical imaging modality for guiding and monitoring prostatic interventions. However, the benefits cannot be readily harnessed for interventional procedures due to difficulties that surround the use of high-field (1.5T or greater) MRI. The inability to use conventional mechatronics and the confined physical space makes it extremely challenging to access the patient. We have designed a robotic assistant system that overcomes these difficulties and promises safe and reliable intraprostatic needle placement inside closed high-field MRI scanners. MRI compatibility of the robot has been evaluated under 3T MRI using standard prostate imaging sequences and average SNR loss is limited to 5%. Needle alignment accuracy of the robot under servo pneumatic control is better than 0.94 mm rms per axis. The complete system workflow has been evaluated in phantom studies with accurate visualization and targeting of five out of five 1 cm targets. The paper explains the robot mechanism and controller design, the system integration, and presents results of preliminary evaluation of the system.

  11. Immunosuppression abrogates resistance of young rabbits to Rabbit Haemorrhagic Disease (RHD).

    PubMed

    Marques, Raquel M; Teixeira, Luzia; Aguas, Artur P; Ribeiro, Joana C; Costa-e-Silva, António; Ferreira, Paula G

    2014-02-04

    Rabbit Haemorrhagic Disease (RHD) is caused by a calicivirus (RHDV) that kills 90% of infected adult European rabbits within 3 days. Remarkably, young rabbits are resistant to RHD. We induced immunosuppression in young rabbits by treatment with methylprednisolone acetate (MPA) and challenged the animals with RHDV by intramuscular injection. All of these young rabbits died within 3 days of infection due to fulminant hepatitis, presenting a large number of RHDV-positive dead or apoptotic hepatocytes, and a significant seric increase in cytokines, features that are similar to those of naïve adult rabbits infected by RHDV. We conclude that MPA-induced immunosuppression abrogates the resistance of young rabbits to RHD, indicating that there are differences in the innate immune system between young and adult rabbits that contribute to their distinct resistance/susceptibility to RHDV infection.

  12. Study of Pneumatic Servo Loading System in Double-Sided Polishing

    NASA Astrophysics Data System (ADS)

    Qian, N.; Ruan, J.; Li, W.

    2006-10-01

    The precise double-sided polishing process is one of the main methods to get the ultra-smooth surface of workpiece. In double-sided polishing machine, a loading system is required to be able to precisely control the load superimposed on the workpiece, while the polishing is being carried out. A pneumatic servo loading system is proposed for this purpose. In the pneumatic servo system, the servo valve, which acts both the electrical to mechanical converter and the power amplifier, has a substantial influence on the performance of the loading system. Therefore a specially designed pneumatic digital servo valve is applied in the control system. In this paper, the construction of the pneumatic servo loading system in double-sided polishing machine and control strategy associated with the digital servo valve are first addressed. The mathematical model of the system established and the hardware of the pneumatic servo system is designed. Finally, the experiments are carried out by measuring the practical load on the workpiece and the quality of the surface finish. It is demonstrated that the error rate of load is less than 5% and a super-smooth surface of silicon wafer with roughness Ra 0.401 nm can be obtained.

  13. Optical Coherence Tomographic Features and Prognosis of Pneumatic Displacement for Submacular Hemorrhage

    PubMed Central

    Bae, Kunho; Cho, Ga Eun; Yoon, Je Moon; Kang, Se Woong

    2016-01-01

    Purpose To identify prognostic factors, including optical coherence tomographic features, of visual outcome in exudative age-related macular degeneration with submacular hemorrhage treated with pneumatic displacement. Methods This retrospective interventional case series included 37 eyes with exudative age-related macular degeneration and submacular hemorrhage, all of which underwent pneumatic displacement. The best-corrected visual acuity (BCVA) was measured at diagnosis and at 3 and 6 months after treatment. In addition to demographic and funduscopic parameters, tomographic features such as reflectance of the submacular hemorrhage were analyzed with regard to BCVA at 6 months. Results After pneumatic displacement and a subsequent treatment such as laser or anti-vascular endothelial growth factor therapy, the BCVA at 3 and 6 months improved significantly (P < 0.001, respectively). Higher baseline BCVA (P < 0.001), shorter symptom duration (P = 0.007), and younger age (P = 0.014) were significant positive prognostic factors on regression analysis. Among optical coherence tomography characteristics, reflectance of the submacular hemorrhage, the shortest radius of the submacular hemorrhage centered on the fovea, and defects in the ellipsoid zone, and external limiting membrane affected the BCVA at 6 months (P < 0.05). Conclusion A favorable visual outcome was demonstrated after initial pneumatic displacement and subsequent treatment for submacular hemorrhage. The submacular hemorrhages exhibiting lower reflectance on optical coherence tomography and a smaller shortest radius from the foveal center were found to be good candidates for pneumatic displacement. PMID:27992524

  14. STATUS OF HIGH FLUX ISOTOPE REACTOR IRRADIATION OF SILICON CARBIDE/SILICON CARBIDE JOINTS

    SciTech Connect

    Katoh, Yutai; Koyanagi, Takaaki; Kiggans, Jim; Cetiner, Nesrin; McDuffee, Joel

    2014-09-01

    Development of silicon carbide (SiC) joints that retain adequate structural and functional properties in the anticipated service conditions is a critical milestone toward establishment of advanced SiC composite technology for the accident-tolerant light water reactor (LWR) fuels and core structures. Neutron irradiation is among the most critical factors that define the harsh service condition of LWR fuel during the normal operation. The overarching goal of the present joining and irradiation studies is to establish technologies for joining SiC-based materials for use as the LWR fuel cladding. The purpose of this work is to fabricate SiC joint specimens, characterize those joints in an unirradiated condition, and prepare rabbit capsules for neutron irradiation study on the fabricated specimens in the High Flux Isotope Reactor (HFIR). Torsional shear test specimens of chemically vapor-deposited SiC were prepared by seven different joining methods either at Oak Ridge National Laboratory or by industrial partners. The joint test specimens were characterized for shear strength and microstructures in an unirradiated condition. Rabbit irradiation capsules were designed and fabricated for neutron irradiation of these joint specimens at an LWR-relevant temperature. These rabbit capsules, already started irradiation in HFIR, are scheduled to complete irradiation to an LWR-relevant dose level in early 2015.

  15. The Rabbit Corneal Pocket Assay.

    PubMed

    Morbidelli, Lucia; Ziche, Marina

    2016-01-01

    The rabbit corneal micropocket angiogenesis assay uses the avascular cornea as a substrate canvas to study angiogenesis in vivo. Through the use of standardized slow-release pellets, a predictable angiogenic response is generated over the course of 1-2 weeks and then quantified. Uniform slow-release pellets are prepared by mixing purified angiogenic growth factors such as basic fibroblast growth factor or vascular endothelial growth factor and a synthetic polymer to allow slow release. A micropocket is surgically created in the rabbit cornea under anesthesia and a pellet implanted. On the days later, the angiogenic response is measured and qualified using a slit lamp, as well as the concomitant vascular phenotype or inflammatory features. The results of the assay are used to assess the ability of potential therapeutic molecules to modulate angiogenesis in vivo, both when released locally or given by ocular formulations or through systemic treatment. In this chapter, the experimental details of the rabbit cornea assay and technical implementations to the original protocol are described.

  16. Minimally Invasive Ear Reshaping With a 1450-nm Diode Laser Using Cryogen Spray Cooling in New Zealand White Rabbits

    PubMed Central

    Holden, Paul K.; Chlebicki, Cara; Wong, Brian J. F.

    2014-01-01

    Background Otoplasty is the current standard of care for treating prominent ears, a psychologically and sometimes functionally disabling disorder. The technically demanding procedure carries many risks such as poor aesthetic outcome, need for revision surgery, and need for general anesthesia. This study investigates the use of laser irradiation combined with cryogen skin cooling and stenting to reshape cartilage in the ears of New Zealand white rabbits. Methods In this prospective, randomized, internally controlled animal study, the right ears of 9 rabbits were mechanically deformed with a jig and then irradiated with a 1450-nm diode laser combined with cryogen skin cooling (14 J/pulse with cryogen spray for 33 milliseconds per cycle and a 6-mm spot size). The left ear served as the control. The ears were splinted for 1, 3, or 4 weeks. The rabbits were then given a lethal dose of intravenous pentobarbital, and the splints were removed and ears examined and photographed. Light and confocal microscopy were performed on the specimens. Results Shape change was observed in all 9 treated rabbit ears, while none of the control ears (stenting alone) showed significant change. Qualitatively, reshaped ears were stiffer after 4 weeks of splinting than after 1 or 3 weeks. None of the rabbits showed evidence of skin injury nor did they show signs of postprocedural pain. Findings from histologic analysis in the treated areas showed evidence of an expanded chondrocyte population in the region of laser irradiation, along with some perichondrial thickening and some fibrosis of the deep dermis. Confocal microscopy revealed minimal cellular death at 1 week and none thereafter. Conclusions Cartilage reshaping using laser energy can be performed safely transcutaneously using cryogen spray cooling in rabbits. This animal model has similarity to human ears with regard to skin and cartilage thickness and is a stepping stone toward developing minimally invasive laser auricle reshaping in

  17. Soft Pneumatic Actuator Fascicles for High Force and Reliability.

    PubMed

    Robertson, Matthew A; Sadeghi, Hamed; Florez, Juan Manuel; Paik, Jamie

    2017-03-01

    Soft pneumatic actuators (SPAs) are found in mobile robots, assistive wearable devices, and rehabilitative technologies. While soft actuators have been one of the most crucial elements of technology leading the development of the soft robotics field, they fall short of force output and bandwidth requirements for many tasks. In addition, other general problems remain open, including robustness, controllability, and repeatability. The SPA-pack architecture presented here aims to satisfy these standards of reliability crucial to the field of soft robotics, while also improving the basic performance capabilities of SPAs by borrowing advantages leveraged ubiquitously in biology; namely, the structured parallel arrangement of lower power actuators to form the basis of a larger and more powerful actuator module. An SPA-pack module consisting of a number of smaller SPAs will be studied using an analytical model and physical prototype. Experimental measurements show an SPA pack to generate over 112 N linear force, while the model indicates the benefit of parallel actuator grouping over a geometrically equivalent single SPA scale as an increasing function of the number of individual actuators in the group. For a module of four actuators, a 23% increase in force production over a volumetrically equivalent single SPA is predicted and validated, while further gains appear possible up to 50%. These findings affirm the advantage of utilizing a fascicle structure for high-performance soft robotic applications over existing monolithic SPA designs. An example of high-performance soft robotic platform will be presented to demonstrate the capability of SPA-pack modules in a complete and functional system.

  18. Soft Pneumatic Actuator Fascicles for High Force and Reliability

    PubMed Central

    Robertson, Matthew A.; Sadeghi, Hamed; Florez, Juan Manuel

    2017-01-01

    Abstract Soft pneumatic actuators (SPAs) are found in mobile robots, assistive wearable devices, and rehabilitative technologies. While soft actuators have been one of the most crucial elements of technology leading the development of the soft robotics field, they fall short of force output and bandwidth requirements for many tasks. In addition, other general problems remain open, including robustness, controllability, and repeatability. The SPA-pack architecture presented here aims to satisfy these standards of reliability crucial to the field of soft robotics, while also improving the basic performance capabilities of SPAs by borrowing advantages leveraged ubiquitously in biology; namely, the structured parallel arrangement of lower power actuators to form the basis of a larger and more powerful actuator module. An SPA-pack module consisting of a number of smaller SPAs will be studied using an analytical model and physical prototype. Experimental measurements show an SPA pack to generate over 112 N linear force, while the model indicates the benefit of parallel actuator grouping over a geometrically equivalent single SPA scale as an increasing function of the number of individual actuators in the group. For a module of four actuators, a 23% increase in force production over a volumetrically equivalent single SPA is predicted and validated, while further gains appear possible up to 50%. These findings affirm the advantage of utilizing a fascicle structure for high-performance soft robotic applications over existing monolithic SPA designs. An example of high-performance soft robotic platform will be presented to demonstrate the capability of SPA-pack modules in a complete and functional system. PMID:28289573

  19. Variable modulus cellular structures using pneumatic artificial muscles

    NASA Astrophysics Data System (ADS)

    Pontecorvo, Michael E.; Niemiec, Robert J.; Gandhi, Farhan S.

    2014-04-01

    This paper presents a novel variable modulus cellular structure based on a hexagonal unit cell with pneumatic artificial muscle (PAM) inclusions. The cell considered is pin-jointed, loaded in the horizontal direction, with three PAMs (one vertical PAM and two horizontal PAMs) oriented in an "H" configuration between the vertices of the cell. A method for calculation of the hexagonal cell modulus is introduced, as is an expression for the balance of tensile forces between the horizontal and vertical PAMs. An aluminum hexagonal unit cell is fabricated and simulation of the hexagonal cell with PAM inclusions is then compared to experimental measurement of the unit cell modulus in the horizontal direction with all three muscles pressurized to the same value over a pressure range up to 758 kPa. A change in cell modulus by a factor of 1.33 and a corresponding change in cell angle of 0.41° are demonstrated experimentally. A design study via simulation predicts that differential pressurization of the PAMs up to 2068 kPa can change the cell modulus in the horizontal direction by a factor of 6.83 with a change in cell angle of only 2.75°. Both experiment and simulation show that this concept provides a way to decouple the length change of a PAM from the change in modulus to create a structural unit cell whose in-plane modulus in a given direction can be tuned based on the orientation of PAMs within the cell and the pressure supplied to the individual muscles.

  20. 76 FR 14906 - Certain New Pneumatic Off-the-Road Tires From the People's Republic of China: Notice of Extension...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-03-18

    ... pneumatic off-the-road tires (``OTR tires'') from the People's Republic of China (``PRC'') for the period... on OTR tires from the PRC. See Certain New Pneumatic Off-the-Road Tires From the People's Republic of... the administrative review of the antidumping order on OTR tires from the PRC, resulting in a...

  1. 49 CFR 236.565 - Provision made for preventing operation of pneumatic brake-applying apparatus by double-heading...

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Provision made for preventing operation of pneumatic brake-applying apparatus by double-heading cock; requirement. 236.565 Section 236.565... preventing operation of pneumatic brake-applying apparatus by double-heading cock; requirement....

  2. 49 CFR 236.565 - Provision made for preventing operation of pneumatic brake-applying apparatus by double-heading...

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 4 2011-10-01 2011-10-01 false Provision made for preventing operation of pneumatic brake-applying apparatus by double-heading cock; requirement. 236.565 Section 236.565... preventing operation of pneumatic brake-applying apparatus by double-heading cock; requirement....

  3. 75 FR 846 - Certain New Pneumatic Off-the-Road Tires From the People's Republic of China: Partial Rescission...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-01-06

    ... International Trade Administration Certain New Pneumatic Off-the-Road Tires From the People's Republic of China... Pneumatic Off-the-Road Tires (OTR Tires) from the People's Republic of China (PRC) for the period December 17, 2007 through December 31, 2008, with respect to the following six companies: 1. Aeolus Tyre...

  4. 78 FR 33059 - Certain New Pneumatic Off-the-Road Tires From the People's Republic of China: Rescission of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-06-03

    ... International Trade Administration Certain New Pneumatic Off-the-Road Tires From the People's Republic of China...'' of the antidumping duty order on certain new pneumatic off-the-road tires from the People's Republic....213(b), the Department received a timely request from Shandong Ling Long Tyre Co., Ltd....

  5. Vibration control of a pneumatic driven piezoelectric flexible manipulator using self-organizing map based multiple models

    NASA Astrophysics Data System (ADS)

    Zhao, Zhi-li; Qiu, Zhi-cheng; Zhang, Xian-min; Han, Jian-da

    2016-03-01

    A kind of hybrid pneumatic-piezoelectric flexible manipulator system has been presented in the paper. A hybrid driving scheme is achieved by combining of a pneumatic proportional valve based pneumatic drive and a piezoelectric actuator bonded to the flexible beam. The system dynamics models are obtained based on system identification approaches, using the established experimental system. For system identification of the flexible piezoelectric manipulator subsystem, parametric estimation methods are utilized. For the pneumatic driven system, a single global linear model is not accurate enough to describe its dynamics, due to the high nonlinearity of the pneumatic driven system. Therefore, a self-organizing map (SOM) based multi-model system identification approach is used to get multiple local linear models. Then, a SOM based multi-model inverse controller and a variable damping pole-placement controller are applied to the pneumatic drive and piezoelectric actuator, respectively. Experiments on pneumatic driven vibration control, piezoelectric vibration control and hybrid vibration control are conducted, utilized proportional and derivative (PD) control, SOM based multi-model inverse controller, and the variable damping pole-placement controller. Experimental results demonstrate that the investigated control algorithms can improve the vibration control performance of the pneumatic driven flexible piezoelectric manipulator system.

  6. [Pneumatic retinopexy using SF6 or C3F8. Results and complications apropos of 56 patients].

    PubMed

    Berrod, J P; Bazard, M C; Bodart, E; Noye, J F; Raspiller, A

    1990-01-01

    56 patients with primary retinal detachment were treated by pneumatic retinopexy. The overall success rate for reattachment with one operation was 66%. Postoperative complications included development of new tears (18%) and P.V.R. (16%). Pneumatic retinopexy is a valuable new technique, however careful patient selection and postoperative management is required.

  7. 75 FR 73998 - Federal Motor Vehicle Safety Standards; New Pneumatic Tires for Motor Vehicles With a Gross...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-11-30

    ... Vehicle Safety Standards; New Pneumatic Tires for Motor Vehicles With a Gross Vehicle Weight Rating (GVWR... Federal motor vehicle safety standard (FMVSS) that applies to new pneumatic tires for use on vehicles with a gross vehicle weight rating (GVWR) greater than 10,000 pounds and motorcycles. In the...

  8. Torque characteristics of a 122-centimeter butterfly valve with a hydro/pneumatic actuator

    NASA Technical Reports Server (NTRS)

    Lin, F. N.; Moore, W. I.; Lundy, F. E.

    1981-01-01

    Actuating torque data from field testing of a 122-centimeter (48 in.) butterfly valve with a hydro/pneumatic actuator is presented. The hydraulic cylinder functions as either a forward or a reverse brake. Its resistance torque increases when the valve speeds up and decreases when the valve slows down. A reduction of flow resistance in the hydraulic flow path from one end of the hydraulic cylinder to the other will effectively reduce the hydraulic resistance torque and hence increase the actuating torque. The sum of hydrodynamic and friction torques (combined resistance torque) of a butterfly valve is a function of valve opening time. An increase in the pneumatic actuating pressure will result in a decrease in both the combined resistance torque and the actuator opening torque; however, it does shorten the valve opening time. As the pneumatic pressure increases, the valve opening time for a given configuration approaches an asymptotical value.

  9. Effective treatment of acne scars using pneumatic injection of hyaluronic acid.

    PubMed

    Patel, Tapan; Tevet, Oren

    2015-01-01

    Acne scars remain a challenging condition to treat despite multiple currently available technologies. This study evaluated the clinical efficacy and safety of pneumatic injections of Hyaluronic Acid in the treatment of acne scars. Two patients (Fitzpatrick skin type IV-V) with acne scars received two sessions of pneumatic, needleless injections of crosslinked hyaluronic acid (HA) at 4-week intervals. The treatment response was assessed by comparing pre- and 3-month posttreatment clinical photography. The patients' acne scar grade improved from 2 to 1 in the first case, and 3 to 2 in the second case, based on independent physician assessment. Patient degree of satisfaction was similar to the physicians' assessment. No significant adverse events were noted. We conclude that pneumatic injection technology to deliver HA to the tissue is an effective and safe method for improving acne scars, even in patients with dark complexion.

  10. A magnetorheological fluid embedded pneumatic vibration isolator allowing independently adjustable stiffness and damping

    NASA Astrophysics Data System (ADS)

    Zhu, Xiaocong; Jing, Xingjian; Cheng, Li

    2011-08-01

    A magnetorheological (MR) fluid embedded pneumatic vibration isolator (MrEPI) with hybrid and compact connection of pneumatic spring and MR damping elements is proposed in this study. The proposed MrEPI system allows independent nonlinear stiffness and damping control with considerable maneuverable ranges. Meanwhile, it allows convenient switching between different passive and active vibration control modes, thus providing more flexibility and versatility in applications. To demonstrate the advantageous dynamic performance of the MrEPI, a nonlinear non-dimensional dynamic model is developed with full consideration of the nonlinear elements involved. A systematic analysis is therefore conducted which can clearly reveal the influence on system output performance caused by each physically important parameter and provide a useful insight into the analysis and design of nonlinear vibration isolators with pneumatic and MR elements.

  11. Automated system for removal and pneumatic transport of fly ash from electric precipitator hoppers

    SciTech Connect

    V.K. Konovalov; O.V. Yashkin; V.V. Ermakov

    2008-03-15

    A system for removal and pneumatic transport of fly ash is examined, in which air pulses act on batches (pistons) of ash formed in a duct. Studies are made of the effect of several physical parameters on the force required to displace a piston of ash and these serve as a basis for choosing a system for removal and pneumatic transport of ash simultaneously from several hoppers of an electric precipitator. This makes it possible to separate the ash particles according to size without introducing additional components. Formulas are given for calculating the structural and dynamic parameters of this system and measurements of indirect dynamic parameters are used to calculate the input-output characteristics of the system. In order to optimize the system, configurations for summing several ducts into a single transport duct for pneumatic ash transport are proposed. Some variants of dry ash utilization and the advantages of producing of size-separated particles are considered.

  12. Powered glove with electro-pneumatic actuation unit for the disabled

    NASA Astrophysics Data System (ADS)

    Kawakami, Kosuke; Kumano, Shinichi; Moromugi, Shunji; Ishimatsu, Takakazu

    2007-12-01

    Authors have been developing a powered glove for people suffering from paralysis on their fingers to support their daily activity. Small air cylinders are used as actuators for this glove. Pneumatically-driven system has high advantages in case soft actuation is preferable. However, there are some problems to be solved in the pneumatically-driven system if the system is supposed to be used in our daily life. Huge air compressor is needed and solenoid valves emit loud sound for example. These problems are hurdles to commercialize the powered glove. To solve these problems authors have developed a new actuation unit by integrating an electric cylinder and an air cylinder. This actuation unit has advantages of both the electric actuation and the pneumatic actuation. Its advanced grip control ability has demonstrated through several experiments. The experimental results are reported in this paper.

  13. Enhancing Mass Lesion of the Sphenoid: Atypical Presentation of Ongoing Pneumatization

    PubMed Central

    Vallabhaneni, Deepak; Badar, Zain; Mangla, Rajiv

    2016-01-01

    Sinus pneumatization is a complex variable process that begins in early life and continues for many years. We present a case of a 6-year-old boy with progressive headaches and neurologic symptoms suggestive of intracranial pathology. The presence of enhancing tissue within the sphenoid sinus created a diagnostic dilemma which leads to a transsphenoidal biopsy. Knowledge of imaging characteristics associated with incomplete pneumatization can help differentiate it from more ominous skull base pathology and prevent unnecessary testing. We describe four-year imaging follow-up in a patient with incomplete pneumatization of the sphenoid sinus presenting as an enhancing mass lesion with subsequent follow-up imaging demonstrating gradual regression and increased aeration of the sphenoid sinus. PMID:28058123

  14. Triggering vacuum capillaries for pneumatic pumping and metering liquids in point-of-care immunoassays.

    PubMed

    Weng, Kuo-Yao; Chou, Nien-Jen; Cheng, Jya-Wei

    2008-07-01

    An innovative vacuum capillary pneumatic actuation concept that can be used for point-of-care testing has been investigated. The vacuum glass capillaries are encapsulated within a laminated pouch and incorporated into the fluidic card. Vacuum glass capillaries broken by external force such as finger pressure, generate the pneumatic forces to induce liquid flow in the fluidic system. The sizes of vacuum capillary play a vital role in the pumping and metering functions of the system. The luteinizing hormone (LH) chromatographic immunoassay performances in the fluidic cards show consistency comparable to that obtained by manual micropipetting. The vacuum capillary pneumatic actuation will be applied in other complex handling step bioassays and lab-on-a-chip devices.

  15. Characterization of a piezoelectric valve for an adaptive pneumatic shock absorber

    NASA Astrophysics Data System (ADS)

    Mikułowski, Grzegorz; Wiszowaty, Rafał; Holnicki-Szulc, Jan

    2013-12-01

    This paper describes a pneumatic valve based on a multilayer piezoelectric actuator and Hörbiger plates. The device was designed to operate in an adaptive pneumatic shock absorber. The adaptive pneumatic shock absorber was considered as a piston-cylinder device and the valve was intended to be installed inside the piston. The main objective for the valve application was regulating the gas flow between the cylinder’s chambers in order to maintain the desired value of the reaction force generated by the shock absorber. The paper describes the design constraints and requirements, together with results of analytical modelling of fluid flow verified versus experimentally obtained data. The presented results indicate that the desired performance characteristics of the valve were obtained. The geometrical constraints of the flow ducts were studied and the actuator’s functional features analysed.

  16. Controllable pneumatic generator based on the catalytic decomposition of hydrogen peroxide

    SciTech Connect

    Kim, Kyung-Rok; Kim, Kyung-Soo Kim, Soohyun

    2014-07-15

    This paper presents a novel compact and controllable pneumatic generator that uses hydrogen peroxide decomposition. A fuel micro-injector using a piston-pump mechanism is devised and tested to control the chemical decomposition rate. By controlling the injection rate, the feedback controller maintains the pressure of the gas reservoir at a desired pressure level. Thermodynamic analysis and experiments are performed to demonstrate the feasibility of the proposed pneumatic generator. Using a prototype of the pneumatic generator, it takes 6 s to reach 3.5 bars with a reservoir volume of 200 ml at the room temperature, which is sufficiently rapid and effective to maintain the repetitive lifting of a 1 kg mass.

  17. Controllable pneumatic generator based on the catalytic decomposition of hydrogen peroxide.

    PubMed

    Kim, Kyung-Rok; Kim, Kyung-Soo; Kim, Soohyun

    2014-07-01

    This paper presents a novel compact and controllable pneumatic generator that uses hydrogen peroxide decomposition. A fuel micro-injector using a piston-pump mechanism is devised and tested to control the chemical decomposition rate. By controlling the injection rate, the feedback controller maintains the pressure of the gas reservoir at a desired pressure level. Thermodynamic analysis and experiments are performed to demonstrate the feasibility of the proposed pneumatic generator. Using a prototype of the pneumatic generator, it takes 6 s to reach 3.5 bars with a reservoir volume of 200 ml at the room temperature, which is sufficiently rapid and effective to maintain the repetitive lifting of a 1 kg mass.

  18. Controllable pneumatic generator based on the catalytic decomposition of hydrogen peroxide

    NASA Astrophysics Data System (ADS)

    Kim, Kyung-Rok; Kim, Kyung-Soo; Kim, Soohyun

    2014-07-01

    This paper presents a novel compact and controllable pneumatic generator that uses hydrogen peroxide decomposition. A fuel micro-injector using a piston-pump mechanism is devised and tested to control the chemical decomposition rate. By controlling the injection rate, the feedback controller maintains the pressure of the gas reservoir at a desired pressure level. Thermodynamic analysis and experiments are performed to demonstrate the feasibility of the proposed pneumatic generator. Using a prototype of the pneumatic generator, it takes 6 s to reach 3.5 bars with a reservoir volume of 200 ml at the room temperature, which is sufficiently rapid and effective to maintain the repetitive lifting of a 1 kg mass.

  19. Combination of the Flow Disturbance Observer and Base Plate Jerk Feedback in a Pneumatic Positioning Stage

    NASA Astrophysics Data System (ADS)

    Wali, Mohebullah; Wakui, Shinji

    Pneumatic actuation systems are commonly used to drive the positioning stage due to several merits. However, one of the critical demerits of the pneumatic systems is the problem of the compressibility, which results in the flow disturbance. Another problem of the positioning stage can be addressed to the vibration which occurs due to the active condition of the base plate. This paper concerns the mentioned two issues in a pneumatic positioning stage. In order to suppress the flow disturbance and to reduce the horizontal vibration of the stage due to the reaction force, a combined control scheme is proposed. This scheme is composed of the fusion of flow disturbance observer (FDOB) and base plate jerk feedback (BPJFB) scheme. An enhanced experimental methodology is provided to successfully implement the fusion of the mentioned feedback controllers. The results show the effectiveness of the proposed method.

  20. Eccentric variation of corneal sensitivity to pneumatic stimulation at different temperatures and with CO2.

    PubMed

    Situ, P; Simpson, T L; Fonn, D

    2007-09-01

    The purpose was to measure corneal sensitivity at multiple corneal positions using pneumatic stimuli, at room temperature and at ocular surface temperature (with and without CO(2) added), in 15 healthy participants. Sensitivity of central, mid-peripheral, and peripheral cornea was measured using a computer-controlled modified Belmonte esthesiometer to deliver pneumatic cool (air at 20 degrees C), mechanical (air at 50 degrees C), and chemical stimuli (air at 50 degrees C with CO(2) added). The ascending method of limits and method of constant stimuli were adopted to determine the threshold to these stimuli at each location. Sensitivity across the cornea using pneumatic stimuli at different temperatures and chemical stimuli varied only slightly. These patterns of variation are different to what has been previously reported using Cochet-Bonnet esthesiometry.

  1. Phytosanitary Irradiation

    PubMed Central

    Hallman, Guy J.; Blackburn, Carl M.

    2016-01-01

    Phytosanitary treatments disinfest traded commodities of potential quarantine pests. Phytosanitary irradiation (PI) treatments use ionizing radiation to accomplish this, and, since their international commercial debut in 2004, the use of this technology has increased by ~10% annually. Generic PI treatments (one dose is used for a group of pests and/or commodities, although not all have been tested for efficacy) are used in virtually all commercial PI treatments, and new generic PI doses are proposed, such as 300 Gy, for all insects except pupae and adult Lepidoptera (moths). Fresh fruits and vegetables tolerate PI better than any other broadly used treatment. Advances that would help facilitate the use of PI include streamlining the approval process, making the technology more accessible to potential users, lowering doses and broadening their coverage, and solving potential issues related to factors that might affect efficacy. PMID:28231103

  2. 76 FR 4287 - New Pneumatic Off-the-Road Tires From the People's Republic of China: Extension of Time Limit for...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-01-25

    ... From the Federal Register Online via the Government Publishing Office DEPARTMENT OF COMMERCE International Trade Administration New Pneumatic Off-the-Road Tires From the People's Republic of China... pneumatic off-the-road tires from the People's Republic of China. See New Pneumatic Off-the-Road Tires...

  3. Status Report on Irradiation Capsules Containing Welded FeCrAl Specimens for Radiation Tolerance Evaluation

    SciTech Connect

    Field, Kevin G.; Howard, Richard H.

    2016-02-26

    This status report provides the background and current status of a series of irradiation capsules, or “rabbits”, that were designed and built to test the contributions of microstructure, composition, damage dose, and irradiation temperature on the radiation tolerance of candidate FeCrAl alloys being developed to have enhanced weldability and radiation tolerance. These rabbits will also test the validity of using an ultra-miniature tensile specimen to assess the mechanical properties of irradiated FeCrAl base metal and weldments. All rabbits are to be irradiated in the High Flux Isotope Reactor (HFIR) at Oak Ridge National Laboratory (ORNL) to damage doses up to ≥15 dpa at temperatures between 200-550°C.

  4. Postcranial pneumaticity and bone structure in two clades of neognath birds.

    PubMed

    Gutzwiller, Sarah C; Su, Anne; O'Connor, Patrick M

    2013-06-01

    Most living birds exhibit some degree of postcranial skeletal pneumaticity, aeration of the postcranial skeleton by pulmonary air sacs and/or directly from the lungs. The extent of pneumaticity varies greatly, ranging from taxa that are completely apneumatic to those with air filling most of the postcranial skeleton. This study examined the influence of skeletal pneumatization on bone structural parameters in a sample of two size- and foraging-style diverse (e.g., subsurface diving vs. soaring specialists) clades of neognath birds (charadriiforms and pelecaniforms). Cortical bone thickness and trabecular bone volume fraction were assessed in one cervical and one thoracic vertebra in each of three pelecaniform and four charadriiform species. Results for pelecaniforms indicate that specialized subsurface dive foragers (e.g., the apneumatic anhinga) have thicker cortical bone and a higher trabecular bone volume fraction than their non-diving clademates. Conversely, the large-bodied, extremely pneumatic brown pelican (Pelecanus occidentalis) exhibits thinner cortical bone and a lower trabecular bone volume fraction. Such patterns in bone structural parameters are here interpreted to pertain to decreased buoyancy in birds specialized in subsurface dive foraging and decreased skeletal density (at the whole bone level) in birds of larger body size. The potential to differentially pneumatize the postcranial skeleton and alter bone structure may have played a role in relaxing constraints on body size evolution and/or habitat exploitation during the course of avian evolution. Notably, similar patterns were not observed within the equally diverse charadriiforms, suggesting that the relationship between pneumaticity and bone structure is variable among different clades of neognath birds.

  5. Design and Control of a 1-DOF MRI Compatible Pneumatically Actuated Robot with Long Transmission Lines

    PubMed Central

    Yang, Bo; Tan, U-Xuan; McMillan, Alan; Gullapalli, Rao; Desai, Jaydev P.

    2011-01-01

    This paper presents the design and control of an MRI-compatible 1-DOF needle driver robot and its precise position control using pneumatic actuation with long transmission lines. MRI provides superior image quality compared to other imaging modalities such as CT or ultrasound, but imposes severe limitations on the material and actuator choice (to prevent image distortion) due to its strong magnetic field. We are primarily interested in developing a pneumatically actuated breast biopsy robot with a large force bandwidth and precise targeting capability during radio-frequency ablation (RFA) of breast tumor, and exploring the possibility of using long pneumatic transmission lines from outside the MRI room to the device in the magnet to prevent any image distortion whatsoever. This paper presents a model of the entire pneumatic system. The pneumatic lines are approximated by a first order system with time delay, because its dynamics are governed by the telegraph equation with varying coefficients and boundary conditions, which cannot be solved precisely. The slow response of long pneumatic lines and valve subsystems make position control challenging. This is further compounded by the presence of non-uniform friction in the device. Sliding mode control (SMC) was adopted, where friction was treated as an uncertainty term to drive the system onto the sliding surface. Three different controllers were designed, developed, and evaluated to achieve precise position control of the RFA probe. Experimental results revealed that all SMCs gave satisfactory performance with long transmission lines. We also performed several experiments with a 3-DOF fiber-optic force sensor attached to the needle driver to evaluate the performance of the device in the MRI under continuous imaging. PMID:22058649

  6. Precision Position Control of Pneumatic Servo Table Embedded with Aerostatic Bearing

    NASA Astrophysics Data System (ADS)

    Tsai, Ming-Hung; Hsu, Tzu-Yung; Pai, Kei-Ren; Shih, Ming-Chang

    This paper treats the control of a pneumatic servo table combining the air cylinders and sliding guides embedded with aerostatic bearing. Since compressed air flows into the small gap between the bearing and the sliding guide, the cylinder floats around the air film and on the guide surface of the table. The friction forces of the pneumatic servo table are measured, and the relation of frictional force and speed is plotted. The hybrid self-tuning fuzzy controller with the velocity compensators and dead-zone are proposed in this paper. From the experimental results, in case of different position, the positioning accuracy can reach the 0.04μm.

  7. Mathematical modeling of pneumatic char injection in a direct reduction rotary kiln

    SciTech Connect

    Ramakrishnan, V.; Sai, P.S.T.

    1999-10-01

    A one-dimensional steady-state mathematical model is proposed for direct reduction process in rotary kilns akin to the SL/RN process. The model takes into account pneumatic coal char injection from the discharge end of the kiln to supplement the heat availability. The model is based on material and energy conservation principles, and the empirical equations for kinetics and heat transfer are obtained from the literature. Predictions are carried out for both iron oxide reduction and ilmenite beneficiation processes. Improvement in the performance was predicted with pneumatic char injection.

  8. Lymphoedema management with the LymphFlow Advance pneumatic compression pump.

    PubMed

    Lee, Natalie; Wigg, Jane; Pugh, Stacy; Barclay, Janet; Moore, Hayley

    2016-10-01

    There are many intermittent pneumatic compression devices available for use in the management and adjunct treatment of lymphatic, venous and arterial disease. This article discusses the development of a new advanced pneumatic compression device, the LymphFlow Advance, which can perform focussed treatment on the lymphoedematous area using a variety of different cycles. Case studies with therapist and patient feedback are used to demonstrate the use of the LymphFlow Advance in the lymphoedema clinic, with a discussion of the evidence to underpin recommended treatment regimes.

  9. The Hydromechanics of Edema Fluid in Lymphedematous Lower Limb During Intermittent Pneumatic Compression.

    PubMed

    Kaczmarek, Mariusz; Olszewski, Waldemar L; Nowak, Joanna; Zaleska, Marzanna

    2015-12-01

    This article presents results of computer simulations of the hydro-mechanical processes in the lymphedematous tissue under stress of a single chamber of sleeve for pneumatic compression. The discussion was focused on parameters of compression as pressures and inflation times to squeeze out the mobile tissue fluid from the edematous tissue. Simulations have predicted that the process of squeezing of tissue fluid is strongly dependent on the pressure in chamber and time of its action. The simulations showed that the values of loads and time applied in currently used pneumatic compression systems are not sufficient to force complete outflow of mobile fluid and pressure dissipation in limb swollen soft tissues.

  10. Position control of an electro-pneumatic system based on PWM technique and FLC.

    PubMed

    Najjari, Behrouz; Barakati, S Masoud; Mohammadi, Ali; Futohi, Muhammad J; Bostanian, Muhammad

    2014-03-01

    In this paper, modeling and PWM based control of an electro-pneumatic system, including the four 2-2 valves and a double acting cylinder are studied. Dynamic nonlinear behavior of the system, containing fast switching solenoid valves and a pneumatic cylinder, as well as electrical, magnetic, mechanical, and fluid subsystems are modeled. A DC-DC power converter is employed to improve solenoid valve performance and suppress system delay. Among different position control methods, a proportional integrator derivative (PID) controller and fuzzy logic controller (FLC) are evaluated. An experimental setup, using an AVR microcontroller is implemented. Simulation and experimental results verify the effectiveness of the proposed control strategies.

  11. IMMUNIZATION OF RABBITS TO INFECTIOUS PAPILLOMATOSIS

    PubMed Central

    Shope, Richard E.

    1937-01-01

    Two intraperitoneal injections of either infectious or non-infectious rabbit papilloma suspensions actively immunize rabbits against papillomatosis. The capacity of the non-infectious suspensions to immunize is considered as evidence that they contain papilloma virus even though none can be demonstrated by the usual infection test. PMID:19870596

  12. Mapping superficial lymphatic territories in the rabbit.

    PubMed

    Soto-Miranda, Miguel A; Suami, Hiroo; Chang, David W

    2013-06-01

    Little is known about the anatomy of the lymphatic system in the rabbit with regard to relationships between the lymphatic vessel and lymph node. According to our previous studies in human cadavers and canines, the superficial lymphatic system could be divided into lymphatic territories. The aim of this study was to completely map the superficial lymphatic system in the rabbit. We used our microinjection technique and histological analysis for dissecting studies and recently developed indocyanine green (ICG) fluorescent lymphography for demonstrating dynamic lymph flow in living rabbits. Real-time ICG fluorescent lymphography was performed in two living New Zealand White rabbits, and direct dye microinjection of the lymphatic vessels was performed in eight dead rabbits. To assess the relationships between the vascular and lymphatic systems in rabbits, we performed radiocontrast injection into arteries in two dead rabbits prior to the lymphatic injection. The ICG fluorescent lymphography revealed eight lymphatic territories in the preauricular, submandibular, root of the lateral neck, axillary, lumbar, inguinal, root of the tail, and popliteal regions. We injected blue acrylic dye into every lymphatic vessel 0.1 mm in diameter or larger. We then dissected and chased the stained lymphatic vessels proximally until the vessels connected to the first tier lymph node. This procedure was repeated throughout the body until all the relationships between the lymphatic vessels and lymph nodes were defined. The lymphatic system of the rabbit could be defined as eight lymphatic territories, each with its own lymphatic vessels and lymph node.

  13. Endoscopic laser reshaping of rabbit tracheal cartilage: preliminary investigations

    NASA Astrophysics Data System (ADS)

    Tsang, Walter; Lam, Anthony; Protsenko, Dmitry; Wong, Brian J.

    2005-04-01

    Background: Tracheal cartilage deformities due to trauma, prolonged endotracheal intubation or infection are difficult to correct. Current treatment options such as dilation, laser ablation, stent placement, and segmental resection are only temporary or carry significant risks. The objectives of this project were to design and test a laser activated endotracheal stent system that can actively modify the geometry of tracheal cartilage, leading to permanent retention of a new and desirable tracheal geometry. Methods: Ex vivo rabbit tracheal cartilage (simulating human neonate trachea) were irradiated with an Er: Glass laser, (λ= 1.54um, 0.5W-2.5W, 1 sec to 5 sec). Shape change and gross thermal injury were assessed visually to determine the best laser power parameters for reshaping. A rigid endoscopic telescope and hollow bronchoscope were used to record endoscopic images. The stent was constructed from nitinol wire, shaped into a zigzag configuration. An ex vivo testing apparatus was also constructed. Results: The best laser power parameter to produce shape change was 1 W for 6-7 seconds. At this setting, there was significant shape change with only minimal thermal injury to the tracheal mucosa, as assessed by visual inspection. The bronchoscopy system functioned adequately during testing in the ex vivo testing apparatus. Conclusion: We have successfully designed instrumentation and created the capability to endoscopically reshape tracheal cartilage in an ex vivo rabbit model. The results obtained in ex vivo tracheal cartilage indicated that reshaping using Er: Glass laser can be accomplished.

  14. Late skin damage in rabbits and monkeys after exposure to particulate radiations

    NASA Technical Reports Server (NTRS)

    Bergtold, D. S.; Cox, A. B.; Lett, J. T.; Su, C. M.

    1983-01-01

    Preliminary results are reported of experiments on the late effects of exposure to particulate radiations on stem cell populations. Skin biopsies were taken from the ears of rabbits irradiated 2-5 years previously with 530 MeV/amu Ar ions (LET 90 keV/micron), or 365 MeV/amu Ne ions (LET 35 keV micron), and from the chests and inner thighs of rhesus monkeys irradiated 16-18 years previously with 32-MeV protons (LET about 1.2 keV/micron). Skin fibroblast cultures obtained from the biopsy samples in rabbits were observed to undergo dose-dependent decreases in in vitro life span, with estimated survival curves showing the effects of Ar-ion irradiation to be more severe than those of Ne-ion irradiation. In addition, the healing of the biopsy wound was observed to become slower as radiation dose increased. In the monkey, radiation reduced the average number of fibroblasts at the time of cessation of growth in culture. Results thus demonstrate the capacity of skin sampling to reveal stem cell destruction, and have important implications for astronauts and other persons at risk of particle exposure with regard to healing responses to trauma or surgery.

  15. Thermal cataract formation in rabbits

    SciTech Connect

    Kramar, P.; Harris, C.; Guy, A.W.

    1987-01-01

    Intraocularly circulating hot water was used to produce cataracts in nine eyes of seven rabbits by maintaining their retrolental temperatures between 43 degrees C and 45 degrees C. A rapid rate of heating (1.3 degrees C/min) plus a sharp temperature gradient across the eye may have been contributing factors in the consistent production of cataracts at these temperatures. Biomicroscopy and light microscopy showed lens changes similar to those associated with acute exposure to microwave radiation. These findings support the assumption that microwave cataractogenesis is due to the local production of elevated temperatures.

  16. Muscle injury induced beneath and distal to a pneumatic tourniquet: A quantitative animal study of effects of tourniquet pressure and duration

    SciTech Connect

    Pedowitz, R.A.; Gershuni, D.H.; Schmidt, A.H.; Friden, J.; Rydevik, B.L.; Hargens, A.R. )

    1991-07-01

    Previous recommendations regarding the safe period of tourniquet hemostasis were based largely on studies of ischemia distal to the tourniquet. This study quantitatively analyzed skeletal muscle injury induced beneath and distal to a pneumatic tourniquet applied to the hindlimbs of rabbits for 1, 2, or 4 hours with a cuff inflation pressure of 125, 200, or 350 mm Hg. Technetium Tc 99m pyrophosphate incorporation after systemic injection (Tc 99 uptake) and correlative histology were used to evaluate tissue damage 2 days after tourniquet application. Compared with the contralateral control limbs, compression and ischemia induced statistically significant increases in Tc 99 uptake in the thigh and leg regions of all groups. Pyrophosphate incorporation was significantly greater in the thigh region than in the leg region after 2 hours of compression in the 200 and 350 mm Hg pressure groups and following 4 hours of compression in all pressure groups. Focal and regional fiber necrosis and degeneration were observed in thigh muscles after 2 hours of tourniquet compression. Two hours of continuous tourniquet application at clinically relevant cuff inflation pressures induced significant skeletal muscle necrosis beneath the tourniquet. Use of the lowest possible inflation pressure for a limited duration should minimize the degree of tissue injury caused by tourniquet application.

  17. Novel Calicivirus Identified in Rabbits, Michigan, USA

    PubMed Central

    Wise, Annabel G.; Bolin, Steven R.; Mullaney, Thomas P.; Kiupel, Matti; Maes, Roger K.

    2009-01-01

    We report a disease outbreak in a Michigan rabbitry of a rabbit calicivirus distinct from the foreign animal disease agent, rabbit hemorrhagic disease virus (RHDV). The novel virus has been designated Michigan rabbit calicivirus (MRCV). Caliciviruses of the Lagovirus genus other than RHDV have not been described in US rabbit populations. The case-fatality rate was 32.5% (65/200). Clinical signs included hemorrhage and sudden death, with hepatic necrosis. Analysis of viral RNA sequence from >95% of the viral genome showed an average similarity of 79% with RHDV. Similarity of the predicted MRCV capsid amino acid sequence ranged from 89.8% to 91.3%, much lower than the 98% amino acid similarity between RHDV strains. Experimentally infected rabbits lacked clinical disease, but MRCV was detected in tissues by PCR. We propose that MRCV primarily causes subclinical infection but may induce overt RHD-like disease under certain field conditions. PMID:19961675

  18. Pneumatic locking device for magnetic bearing reaction wheel

    NASA Astrophysics Data System (ADS)

    Privat, Michel; da Costa, Arlindo

    2003-09-01

    Due to the launch vibration environment, the use of locking device is necessary for large or heavy mechanisms. This remark is true in particular for the inertial actuators like magnetic bearing reaction wheels. These actuators have a rotor that is in magnetic levitation without any contact with the stator. Locking device is mandatory to maintain the rotor during the launch vibrations. To avoid contact between rotor and stator during the functional phase, the link created by the locking device must be completely released. This article presents a pneumatic locking device with pyrotechnical sub-systems that have been realised by "ALCATEL Space Industries" for the reaction wheels development in the frame of a CNES satellites family. The first paragraph presents the wheel functioning and briefly describes the Electro-mechanical components of the reaction wheel. The second paragraph describes a device based on a metallic bellows ring. A nitrogen pressure in the ring allows pushing the rotor against the stator. The rotor release is obtained by drilling the system tubing with a pyrotechnic valve. The third point describes the qualification tests and the resulting data. Some functional tests are made in warm and cold case with the locking device in order to improve some mechanical characteristics including the locking effort generated and the leakage rate. Launch vibrations and thermal tests have been realised and the good functioning of the mechanism is proven. At the end of these tests, the qualification has been pronounced. The device is now implemented within the reaction wheel. This equipment should flight in 2004. The next paragraph presents the works realised under CNES Research and Technology contract. The objectives were the characterisation of metallic bellows and some technological studies to improve the knowledge of the mechanical and functional characteristics of these elements. The first study was to create a Finite Element model of a bellow in order to

  19. Ex vivo investigations of laser auricular cartilage reshaping with carbon dioxide spray cooling in a rabbit model.

    PubMed

    Wu, Edward C; Sun, Victor; Manuel, Cyrus T; Protsenko, Dmitriy E; Jia, Wangcun; Nelson, J Stuart; Wong, Brian J F

    2013-11-01

    Laser cartilage reshaping (LCR) with cryogen spray cooling is a promising modality for producing cartilage shape change while reducing cutaneous thermal injury. However, LCR in thicker tissues, such as auricular cartilage, requires higher laser power, thus increasing cooling requirements. To eliminate the risks of freeze injury characteristic of high cryogen spray pulse rates, a carbon dioxide (CO2) spray, which evaporates rapidly from the skin, has been proposed as the cooling medium. This study aims to identify parameter sets which produce clinically significant reshaping while producing minimal skin thermal injury in LCR with CO2 spray cooling in ex vivo rabbit auricular cartilage. Excised whole rabbit ears were mechanically deformed around a cylindrical jig and irradiated with a 1.45-μm wavelength diode laser (fluence 12-14 J/cm(2) per pulse, four to six pulse cycles per irradiation site, five to six irradiation sites per row for four rows on each sample) with concomitant application of CO2 spray (pulse duration 33-85 ms) to the skin surface. Bend angle measurements were performed before and after irradiation, and the change quantified. Surface temperature distributions were measured during irradiation/cooling. Maximum skin surface temperature ranged between 49.0 to 97.6 °C following four heating/cooling cycles. Significant reshaping was achieved with all laser dosimetry values with a 50-70 °C difference noted between controls (no cooling) and irradiated ears. Increasing cooling pulse duration yielded progressively improved gross skin protection during irradiation. CO2 spray cooling may potentially serve as an alternative to traditional cryogen spray cooling in LCR and may be the preferred cooling medium for thicker tissues. Future studies evaluating preclinical efficacy in an in vivo rabbit model are in progress.

  20. The influence of He-Ne laser on scar formation after trabeculectomy in rabbits

    PubMed Central

    Hu, Jun; Li, Gui-Gang; Zhang, Hong; Xiang, Nan; Chen, Zhi-Qi; Wang, Rui-Lin; Xiang, Yan; Li, Bin; Li, Zheng-Jia; He, Yan-Yan; Wang, Li-Fang

    2010-01-01

    AIM To investigate the influence of He-Ne lasers on scar formation in the filtration canal after trabeculectomy in a rabbit model, as well as to explore the mechanisms for preventing scar formation when using He-Ne lasers in vivo. METHODS Experiment 1: Four groups were established (four eyes in each group). In 12 eyes, the upper nasal limbus area next to the upper rectus muscle received 10 minutes of He-Ne laser irradiation (100, 150, 200mW/cm2; 60, 90, 120J/cm2) every day for three days. Four eyes served as controls. Twenty-four hours after the final irradiation, the rabbits were sacrificed and the irradiated tissue was excised, fixed with paraformaldehyde and tested for proliferating cell nuclear antigen (PCNA), connective tissue growth factor (CTGF) and apoptosis (TUNEL). Experiment 2: Forty-two rabbits were randomly divided into two groups and standard trabeculectomy was performed in the right eyes either after 200mW/cm2 He-Ne laser irradiation or not in the filtration area. The expression of PCNA and CTGF, apoptosis and collagen density in the filtration area were tested on the 7th, 14th and 28th day after surgery. RESULTS Experiment 1: There were no more PCNA and CTGF positive cells in the He-Ne irradiation group than in the control group. No apoptotic cells were found in either group. Experiment 2: The expression of PCNA and CTGF was lower in the He-Ne irradiation group than in the control group on the 7th and 14th day after trabeculectomy surgery (P<0.05); no apoptotic cells were detected in either group. Collagen density was significantly lower in the He-Ne irradiation group than in the control group on the 14th and 28th day after surgery (P<0.05). CONCLUSION Pretreating the filtration area with 200mW/cm2 (120J/cm2) of He-Ne laser irradiation may be helpful in preventing scar formation after trabeculectomy, possibly due to the downregulation of the expression of PCNA, CTGF and collagen synthesis in fibroblasts. PMID:22553536

  1. Use of Irradiated Foods

    NASA Technical Reports Server (NTRS)

    Brynjolfsson, A.

    1985-01-01

    The safety of irradiated foods is reviewed. Guidelines and regulations for processing irradiated foods are considered. The radiolytic products formed in food when it is irradiated and its wholesomeness is discussed. It is concluded that food irradiation processing is not a panacea for all problems in food processing but when properly used will serve the space station well.

  2. Behavioral fever in newborn rabbits

    NASA Technical Reports Server (NTRS)

    Satinoff, E.; Mcewen, G. N., Jr.; Williams, B. A.

    1976-01-01

    New Zealand white rabbit pups aged 12 to 72 hr were divided into three groups and given an intraperitoneal injection of Pseudomonas polysaccharide, a saline vehicle alone, and no treatment, respectively. The animals injected with pyrogen and maintained at an ambient temperature of 32 C for 2 hr did not develop fever. When placed in a thermally graded alleyway, the animals injected with pyrogen selected gradient positions that represented significantly higher temperatures than controls injected with saline. Further stay at selected positions for 5 min caused a considerable increase in the rectal temperature of the pyrogen-injected pups but not that of controls. The results support the hypothesis that newborn rabbits will develop a fever by behavioral means after a single injection of an exogenous pyrogen if the opportunity for thermoregulatory behavior is present. No fever develops if the pups must rely solely on internal thermoregulatory mechanisms. The behavioral system for producing a fever is mature at birth, but an adequate system of internal reflexes does not appear to develop for some days.

  3. A reduced-order model-based study on the effect of intermittent pneumatic compression of limbs on the cardiovascular system.

    PubMed

    Maffiodo, Daniela; De Nisco, Giuseppe; Gallo, Diego; Audenino, Alberto; Morbiducci, Umberto; Ferraresi, Carlo

    2016-04-01

    This work investigates the effect that the application of intermittent pneumatic compression to lower limbs has on the cardiovascular system. Intermittent pneumatic compression can be applied to subjects with reduced or null mobility and can be useful for therapeutic purposes in sports recovery, deep vein thrombosis prevention and lymphedema drainage. However, intermittent pneumatic compression performance and the effectiveness are often difficult to predict. This study presents a reduced-order numerical model of the interaction between the cardiovascular system and the intermittent pneumatic compression device. The effect that different intermittent pneumatic compression operating conditions have on the overall circulation is investigated. Our findings confirm (1) that an overall positive effect on hemodynamics can be obtained by properly applying the intermittent pneumatic compression device and (2) that using intermittent pneumatic compression for cardiocirculatory recovery is feasible in subjects affected by lower limb disease.

  4. Comparitive Assessment of Isokinetic and Pneumatic Lower Limb Strength in Functionally-Limited Elderly Subjects

    Technology Transfer Automated Retrieval System (TEKTRAN)

    The purpose of this study was to investigate the relationship between isokinetic and pneumatic knee extensor strength in functionally-limited elders and to compare the respective changes in knee extensor peak torque and one repetition maximum strength (1RM) after a randomized controlled progressive ...

  5. Experimental Development and Evaluation of Pneumatic Powered-Lift Super-STOL Aircraft

    NASA Technical Reports Server (NTRS)

    Englar, Robert J.; Campbell, Bryan A.

    2005-01-01

    The powered-lift Channel Wing concept has been combined with pneumatic Circulation Control aerodynamic and propulsive technology to generate a Pneumatic Channel Wing (PCW) configuration intended to have Super-STOL or VSTOL capability while eliminating many of the operational problem areas of the original Channel Wing vehicle. Wind-tunnel development and evaluations of a PCW powered model conducted at Georgia Tech Research Institute (GTRI) have shown substantial lift capabilities for the blown configuration (CL values of 10 to 11). Variation in blowing of the channel was shown to be more efficient than variation in propeller thrust in terms of lift generation. Also revealed was the ability to operate unstalled at very high angles of attack of 40 deg - 45 deg, or to achieve very high lift at much lower angle of attack to increase visibility and controllability. In order to provide greater flexibility in Super-STOL takeoffs and landings, the blown model also displayed the ability to interchange thrust and drag by varying blowing without any moving parts. A preliminary design study of this pneumatic vehicle based on the two technologies integrated into a simple Pneumatic Channel Wing configuration showed very strong Super-STOL potential. This paper presents these experimental results, discusses variations in the configuration geometry under development, and addresses additional considerations to extend this integrated technology to advanced design studies of PCW-type vehicles.

  6. Experimental characterization of the effects of pneumatic tubing on unsteady pressure measurements

    NASA Technical Reports Server (NTRS)

    Whitmore, Stephen A.; Lindsey, William T.; Curry, Robert E.; Gilyard, Glenn B.

    1990-01-01

    Advances in aircraft control system designs have, with increasing frequency, required that air data be used as flight control feedback. This condition requires that these data be measured with accuracy and high fidelity. Most air data information is provided by pneumatic pressure measuring sensors. Typically unsteady pressure data provided by pneumatic sensing systems are distorted at high frequencies. The distortion is a result of the pressure being transmitted to the pressure sensor through a length of connective tubing. The pressure is distorted by frictional damping and wave reflection. As a result, air data provided all-flush, pneumatically sensed air data systems may not meet the frequency response requirements necessary for flight control augmentation. Both lab and flight test were performed at NASA-Ames to investigate the effects of this high frequency distortion in remotely located pressure measurement systems. Good qualitative agreement between lab and flight data are demonstrated. Results from these tests are used to describe the effects of pneumatic distortion in terms of a simple parametric model.

  7. Numerical Simulation on the Response Characteristics of a Pneumatic Microactuator for Microfluidic Chips.

    PubMed

    Liu, Xuling; Li, Songjing; Bao, Gang

    2016-06-01

    This article presents a multiphysical system modeling and simulation of a pneumatic microactuator, which significantly influences the performance of a particular pneumatic microfluidic device. First, the multiphysical system modeling is performed by developing a physical model for each of its three integrated components: microchannel with a microvalve, a gas chamber, and an elastomer membrane. This is done for each step of operation for the whole system. The whole system is then considered a throttle blind capacitor model, and it is used to predict the response time of the pneumatic microactuator by correlating its characteristics such as gas pressurizing, hydraulic resistance, and membrane deformation. For this microactuator, when the maximum membrane deformation is 100 µm, the required actuated air pressure is 80 kPa, and the response time is 1.67 ms when the valve-opening degree is 0.8. The response time is 1.61 ms under fully open conditions. These simulated results are validated by the experimental results of the current and previous work. A correlation between the simulated and experimental results confirms that the multiphysical modeling presented in this work is applicable in developing a proper design of a pneumatic microactuator. Finally, the influencing factors of the response time are discussed and analyzed.

  8. Pressurization, Pneumatic, and Vent Subsystems of the X-34 Main Propulsion System

    NASA Technical Reports Server (NTRS)

    Hedayat, A.; Steadman, T. E.; Brown, T. M.; Knight, K. C.; White, C. E., Jr.; Champion, R. H., Jr.

    1998-01-01

    In pressurization systems, regulators and orifices are use to control the flow of the pressurant. For the X-34 Main Propulsion System, three pressurization subsystem design configuration options were considered. In the first option, regulators were used while in the other options, orifices were considered. In each design option, the vent/relief system must be capable of relieving the pressurant flow without allowing the tank pressure to rise above proof, therefore, impacts on the propellant tank vent system were investigated and a trade study of the pressurization system was conducted. The analysis indicated that design option using regulators poses least risk. Then, a detailed transient thermal/fluid analysis of the recommended pressurization system was performed. Helium usage, thermodynamic conditions, and overpressurization of each propellant tank were evaluated. The pneumatic and purge subsystem is used for pneumatic valve actuation, Inter-Propellant Seal purges, Engine Spin Start, and engine purges at the required interface pressures, A transient analysis of the pneumatic and purge subsystem provided helium usage and flow rates to Inter-Propellant Seal and engine interfaces. Fill analysis of the helium bottles of pressurization and pneumatic subsystems during ground operation was performed. The required fill time and the stored

  9. Optimization of pneumatic sheet extrusion of whole wheat flour poory dough using response surface methodology.

    PubMed

    Murthy, K Venkatesh; Sudha, M L; Ravi, R; Raghavarao, K S M S

    2015-07-01

    Pneumatic extrusion of whole wheat flour dough is a challenge in the preparation of Poory. In the present study, the pneumatic extrusion process variables (pneumatic pressure, rate of extrusion) and quality of deep fried product (oil uptake, frying time, puffed height) was evaluated to get Poory of maximum overall sensory quality, minimum shear and minimum oil uptake. These parameters depend on the moisture content of wheat dough. Response surface methodology was demonstrated to be an efficient tool for the optimization of process parameters of pneumatic extrusion. The results indicated that extrusion pressure ranging from 3 ~ 6 × 10(5) Pa for the whole wheat flour dough with added moisture of 56 ~ 60 % was found to give a uniform rate of extruded sheet. It was observed that submerged frying time for the extruded dough sheet was in the range of 35 ~ 40 s, with the temperature of the vegetable oil to be in the range of 180 ~ 185 °C. Oil uptake during frying was about 12 ± 1 % and the textural shear force was found to be 9.9 N with an overall sensory score of 7.2 ± 0.5 on nine point scale. The experimental errors for all attributes were non-significant (p > 0.05) and thus optimum variables predicted by the model are found suitable.

  10. Pneumatic shutoff and time-delay valve operates at controlled rate

    NASA Technical Reports Server (NTRS)

    Horning, J. L.; Tomlinson, L. E.

    1966-01-01

    Shutoff and time delay valve, which incorporates a metering spool that moves at constant velocity under pneumatic pressure and spring compression, increases fluid-flow area at a uniform rate. Diaphragm areas, control cavity volume, and bleed-orifice size may be varied to give any desired combination of time delay and spool travel time.

  11. DEMONSTRATION BULLETIN: PNEUMATIC FRACTURING EXTRACTION™ AND HOT GAS INJECTION, PHASE I - ACCUTECH REMEDIAL SYSTEMS, INC.

    EPA Science Inventory

    The Pneumatic Fracturing Extraction(PFE) process developed by Accutech Remedial Systems, Inc. makes it possible to use vapor extraction to remove volatile organics at increased rates from a broader range of vadose zones. The low permeability of silts, clays, shales, etc. would ot...

  12. ACCUTECH PNEUMATIC FRACTURING EXTRACTION AND HOT GAS INJECTION, PHASE I - APPLICATIONS ANALYSIS REPORT

    EPA Science Inventory

    This document summarizes and analyzes the results of a 4-wk evaluation of the Accutech Remedial Systems, Inc. (ARS) Pneumatic Fracturing Extraction™ (PFE™) process for increasing the removal of volatile organic contaminants from the vadose zone, particularly where the ground form...

  13. Pneumatic method for making fast, higher-resolution, noncontacting measurement of surface topography

    NASA Astrophysics Data System (ADS)

    Woolley, Ronald W.

    1992-04-01

    Fluid Film Devices Ltd specialises mainly in the design and manufacture of self-acting or aerodynamic gas bearings. The geometric tolerances needed for these bearings can be of the order of O.lum. It was the need for rapid, noncontacting measurement of components, often made of ceramic material, that led to the re-development of the Pneumatic Probe (PP).

  14. U.S. ENVIRONMENTAL PROTECTION AGENCY'S SUPERFUND INNOVATIVE TECHNOLOGY EVALUATION OF PNEUMATIC FRACTURING EXTRACTION

    EPA Science Inventory

    The U.S. Environmental Protection Agency (EPA), in cooperation with Accutech Remedial Systems (ARS) and the New Jersey Institute of Technology (NJIT) performed a field demonstration of Pneumatic Fracturing Extraction (PFE) for the removal of chlorinated volatile organics (VOCS) f...

  15. 46 CFR 56.97-35 - Pneumatic tests (replaces 137.5).

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... SYSTEMS AND APPURTENANCES Pressure Tests § 56.97-35 Pneumatic tests (replaces 137.5). (a) General... its brittle fracture properties. (c) Check of test equipment before applying pressure. The test... should not be subjected to the test pressure have been disconnected or isolated by valves or...

  16. 46 CFR 56.97-35 - Pneumatic tests (replaces 137.5).

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... SYSTEMS AND APPURTENANCES Pressure Tests § 56.97-35 Pneumatic tests (replaces 137.5). (a) General... its brittle fracture properties. (c) Check of test equipment before applying pressure. The test... should not be subjected to the test pressure have been disconnected or isolated by valves or...

  17. 46 CFR 56.97-35 - Pneumatic tests (replaces 137.5).

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... SYSTEMS AND APPURTENANCES Pressure Tests § 56.97-35 Pneumatic tests (replaces 137.5). (a) General... its brittle fracture properties. (c) Check of test equipment before applying pressure. The test... should not be subjected to the test pressure have been disconnected or isolated by valves or...

  18. 46 CFR 56.97-35 - Pneumatic tests (replaces 137.5).

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... SYSTEMS AND APPURTENANCES Pressure Tests § 56.97-35 Pneumatic tests (replaces 137.5). (a) General... its brittle fracture properties. (c) Check of test equipment before applying pressure. The test... should not be subjected to the test pressure have been disconnected or isolated by valves or...

  19. 46 CFR 56.97-35 - Pneumatic tests (replaces 137.5).

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... SYSTEMS AND APPURTENANCES Pressure Tests § 56.97-35 Pneumatic tests (replaces 137.5). (a) General... its brittle fracture properties. (c) Check of test equipment before applying pressure. The test... should not be subjected to the test pressure have been disconnected or isolated by valves or...

  20. Vacuum pressure generation via microfabricated converging-diverging nozzles for operation of automated pneumatic logic.

    PubMed

    Christoforidis, Theodore; Werner, Erik M; Hui, Elliot E; Eddington, David T

    2016-08-01

    Microfluidic devices with integrated pneumatic logic enable automated fluid handling without requiring external control instruments. These chips offer the additional advantage that they may be powered by vacuum and do not require an electricity source. This work describes a microfluidic converging-diverging (CD) nozzle optimized to generate vacuum at low input pressures, making it suitable for microfluidic applications including powering integrated pneumatic logic. It was found that efficient vacuum pressure was generated for high aspect ratios of the CD nozzle constriction (or throat) width to height and diverging angle of 3.6(o). In specific, for an inlet pressure of 42.2 psia (290.8 kPa) and a volumetric flow rate of approximately 1700 sccm, a vacuum pressure of 8.03 psia (55.3 kPa) was generated. To demonstrate the capabilities of our converging - diverging nozzle device, we connected it to a vacuum powered peristaltic pump driven by integrated pneumatic logic and obtained tunable flow rates from 0 to 130 μL/min. Finally, we demonstrate a proof of concept system for use where electricity and vacuum pressure are not readily available by powering a CD nozzle with a bicycle tire pump and pressure regulator. This system is able to produce a stable vacuum sufficient to drive pneumatic logic, and could be applied to power automated microfluidics in limited resource settings.

  1. 21 CFR 874.4250 - Ear, nose, and throat electric or pneumatic surgical drill.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES EAR, NOSE, AND THROAT DEVICES Surgical Devices § 874... throat electric or pneumatic surgical drill is a rotating drilling device, including the handpiece, that... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Ear, nose, and throat electric or...

  2. 21 CFR 874.4250 - Ear, nose, and throat electric or pneumatic surgical drill.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES EAR, NOSE, AND THROAT DEVICES Surgical Devices § 874... throat electric or pneumatic surgical drill is a rotating drilling device, including the handpiece, that... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Ear, nose, and throat electric or...

  3. Troubleshooting of an Electromechanical System (Westinghouse PLC Controlling a Pneumatic Robot). High-Technology Training Module.

    ERIC Educational Resources Information Center

    Tucker, James D.

    This training module on the troubleshooting of an electromechanical system, The Westinghouse Programmable Logic Controller (PLC) controlling a pneumatic robot, is used for a troubleshooting unit in an electromechanical systems/robotics and automation systems course. In this unit, students locate and repair a defect in a PLC-operated machine. The…

  4. The application of pneumatic jigging in the recovery of metallic fraction from shredded printed wiring boards.

    PubMed

    Wang, Zheng; Hall, Philip; Miles, Nicholas J; Wu, Tao; Lambert, Peter; Gu, Fu

    2015-09-01

    Waste electrical and electronic equipment (WEEE) is one of the fastest growing waste streams worldwide with volumes increasing by 40% each year. WEEE has attracted increasing concern worldwide due to its high metal content and the potential environmental threat which results from uncontrolled recycling practices. Innovative physical separation techniques for WEEE recycling are preferential compared with chemical methods because of the reduction of energy and chemical consumption as well as potential environmental threats. Pneumatic jigging is a dry separation process capable of achieving good separation of coarse material within a very narrow density range, which makes it suitable as a pretreatment process for WEEE recycling. The work presented in this paper investigates the potential application of pneumatic jigging in metal recovery from WEEE. A pilot scale pneumatic jig has been developed by University of Nottingham Ningbo to separate shredded printed wiring boards into two streams: a light fraction (mainly non-metallic fraction consisting of glass fiber, fluffs, and plastic pieces) and dense fraction (metallic fraction). The novelty of work presented in this paper is the application of a dry separation technique in WEEE recycling for metal recovery. Compared with conventional wet separation processes involved in WEEE recycling industry, dry separation has the advantage of zero secondary pollution. The results of this experimental program show pneumatic jigging to be an effective and environmental friendly technique as a pretreatment process for the recovery of the metallic fraction from shredded WEEE.

  5. Aircraft Fuel, Hydraulic and Pneumatic Systems (Course Outlines), Aviation Mechanics 3 (Air Frame): 9067.01.

    ERIC Educational Resources Information Center

    Dade County Public Schools, Miami, FL.

    This document presents an outline for a 135-hour course designed to familiarize the student with the operation, inspection, and repair of aircraft fuel, hydraulic, and pneumatic systems. It is designed to help the trainee master the knowledge and skills necessary to become an aviation airframe mechanic. The aviation airframe maintenance technician…

  6. Pneumatization of Mastoid Air Cells, Temporal Bone, Ethmoid and Sphenoid Sinuses. Any Correlation?

    PubMed

    Hindi, Khalid; Alazzawi, Sarmad; Raman, Rajagopalan; Prepageran, Narayanan; Rahmat, Kartini

    2014-12-01

    The aim of this study is to assess the pneumatization of the paranasal sinuses (PNS) and other parts of temporal bone such as mastoid air cells and to investigate if there was any association between the aeration of these structures among the three major ethnic groups in Malaysia (Malay, Chinese, Indian) as this would be representative of Asia. A retrospective review of 150 computed tomography (CT) scans of PNS and temporal bones was done and analysed. The pneumatization of each area was obtained and compared using statistical analysis. Patients with a history of previous medical or surgical problems in the intended areas were excluded from the study. The pneumatization of the mastoid air cells and other temporal bone parts were noted to be symmetrical in more than 75 %. There was a positive correlation between the pneumatization of mastoid air cells and that of the sphenoid sinus. The prevalence of Agger nasi, Haller's and Onodi cells was observed to be significantly higher in the Chinese group. Preoperative assessment of the temporal bone and PNS with CT scan may be helpful in the evaluation of their anatomical landmark and decrease the possibility of surgical complications related to 3D structures.

  7. 40 CFR 60.5390 - What standards apply to pneumatic controller affected facilities?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 7 2014-07-01 2014-07-01 false What standards apply to pneumatic controller affected facilities? 60.5390 Section 60.5390 Protection of Environment ENVIRONMENTAL PROTECTION... reconstructed on or after October 15, 2013, at a location between the wellhead and a natural gas...

  8. 40 CFR 60.5390 - What standards apply to pneumatic controller affected facilities?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 7 2013-07-01 2013-07-01 false What standards apply to pneumatic controller affected facilities? 60.5390 Section 60.5390 Protection of Environment ENVIRONMENTAL PROTECTION... at a location between the wellhead and a natural gas processing plant must have a bleed rate...

  9. Development of Pneumatic Channel Wing Powered-Lift Advanced Super-STOL Aircraft

    NASA Technical Reports Server (NTRS)

    Englar, Robert J.; Campbell, Bryan A.

    2002-01-01

    The powered-lift Channel Wing concept has been combined with pneumatic Circulation Control aerodynamic and propulsive technology to generate a Pneumatic Channel Wing configuration intended to have Super-STOL or VSTOL capability while eliminating many of the operational problem areas of the original Channel Wing vehicle. A preliminary design study of this pneumatic vehicle based on previous wind-tunnel and flight-test data for the two technologies integrated into a simple Pneumatic Channel Wing (PCW) configuration showed very strong Super-STOL potential. Wind-tunnel development and evaluations of a PCW powered model conducted at Georgia Tech Research Institute (GTRI) have shown substantial lift capabilities for the blown configuration (C(sub L) values of 8.5 to 9.0). Variation in blowing of the channel was shown to be more efficient than variation in propeller thrust. Also revealed was the ability to operate unstalled at very high angles of attack of 40 deg-45 deg, or to achieve very high lift at much lower angle of attack to increase visibility and controllability. In order to provide greater flexibility in Super-STOL takeoffs and landings, the blown model also displayed the ability to interchange thrust and drag by varying blowing without any moving parts. This paper presents these experimental results, discusses variations in the configuration geometry under development, and extends this integrated technology to advanced design studies of PCW-type vehicles.

  10. 46 CFR 108.409 - Location and spacing of tubing in pneumatic fire detection system.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 4 2014-10-01 2014-10-01 false Location and spacing of tubing in pneumatic fire detection system. 108.409 Section 108.409 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS DESIGN AND EQUIPMENT Fire Extinguishing Systems § 108.409...

  11. 46 CFR 108.409 - Location and spacing of tubing in pneumatic fire detection system.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 4 2012-10-01 2012-10-01 false Location and spacing of tubing in pneumatic fire detection system. 108.409 Section 108.409 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS DESIGN AND EQUIPMENT Fire Extinguishing Systems § 108.409...

  12. 46 CFR 108.409 - Location and spacing of tubing in pneumatic fire detection system.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 4 2013-10-01 2013-10-01 false Location and spacing of tubing in pneumatic fire detection system. 108.409 Section 108.409 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS DESIGN AND EQUIPMENT Fire Extinguishing Systems § 108.409...

  13. Challenging In-Situ Strain Measurement In Pneumatic Bulging Of AA5083

    NASA Astrophysics Data System (ADS)

    Liewald, M.; Kappes, J.

    2011-05-01

    Superplastic forming of sheet metal aluminum alloys exhibits numerous technical and economical advantages for manufacturing of complex part geometries in niche type production. For virtual engineering tasks prior manufacturing of superplastic forming equipment such as forming dies, numerical sheet metal forming simulations and material parameters are crucial. In such context the selected testing procedure should be as similar as possible to the subsequent forming technique. For that reason the pneumatic bulge test represents an appropriate testing procedure for the most common superplastic forming process—the blow forming process. In-situ strain measurement of pneumatic bulging AA5083 at 500° C results in high requirements in terms of the grid applied on the blank surface due to process temperature and large strain values. These large strain values result into pole heights up to 70 mm of the bulge test specimens using an initial blank thickness of 1.5 mm and a circular die opening of 100 mm. This paper describes the influence of different grid types and finally proposes adequate grid types for in-situ strain measurement for pneumatic bulging of AA5083. Furthermore the capabilities of in-situ measurement of strains during pneumatic bulging of AA5083 are highlighted.

  14. [The research on linear control of pneumatic artificial muscles used in medical robots].

    PubMed

    Lin, Linang-ming; Tian, She-ping; Yan, Guo-zheng

    2002-01-01

    This paper presents the properties of Pneumatic artificial muscles and its application in medical robots. The linear model construction and minimum predictive error control algorithm for artificial muscles are discussed here too. This paper provides the experimental results of linear adaptive control, which show the control algorithm has certain applicable value.

  15. LPT. Low power test (TAN641) interior. Heating and ventilating pneumatic ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    LPT. Low power test (TAN-641) interior. Heating and ventilating pneumatic and electrical control panel. Contract nearly complete. Photographer: Jack L. Anderson. Date: December 19, 1957. INEEL negative no. 57-6198 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID

  16. 46 CFR 108.409 - Location and spacing of tubing in pneumatic fire detection system.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 4 2011-10-01 2011-10-01 false Location and spacing of tubing in pneumatic fire detection system. 108.409 Section 108.409 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS DESIGN AND EQUIPMENT Fire Extinguishing Systems § 108.409...

  17. 9 CFR 354.124 - Quarantine of diseased rabbits.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 9 Animals and Animal Products 2 2012-01-01 2012-01-01 false Quarantine of diseased rabbits. 354... INSPECTION AND CERTIFICATION VOLUNTARY INSPECTION OF RABBITS AND EDIBLE PRODUCTS THEREOF Inspection Procedures; Ante-Mortem Inspections § 354.124 Quarantine of diseased rabbits. If live rabbits, which...

  18. 9 CFR 354.124 - Quarantine of diseased rabbits.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 9 Animals and Animal Products 2 2011-01-01 2011-01-01 false Quarantine of diseased rabbits. 354... INSPECTION AND CERTIFICATION VOLUNTARY INSPECTION OF RABBITS AND EDIBLE PRODUCTS THEREOF Inspection Procedures; Ante-Mortem Inspections § 354.124 Quarantine of diseased rabbits. If live rabbits, which...

  19. 9 CFR 354.124 - Quarantine of diseased rabbits.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 9 Animals and Animal Products 2 2013-01-01 2013-01-01 false Quarantine of diseased rabbits. 354... INSPECTION AND CERTIFICATION VOLUNTARY INSPECTION OF RABBITS AND EDIBLE PRODUCTS THEREOF Inspection Procedures; Ante-Mortem Inspections § 354.124 Quarantine of diseased rabbits. If live rabbits, which...

  20. 9 CFR 354.124 - Quarantine of diseased rabbits.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 9 Animals and Animal Products 2 2014-01-01 2014-01-01 false Quarantine of diseased rabbits. 354... INSPECTION AND CERTIFICATION VOLUNTARY INSPECTION OF RABBITS AND EDIBLE PRODUCTS THEREOF Inspection Procedures; Ante-Mortem Inspections § 354.124 Quarantine of diseased rabbits. If live rabbits, which...

  1. Electro pneumatic trainer embedded with programmable integrated circuit (PIC) microcontroller and graphical user interface platform for aviation industries training purposes

    NASA Astrophysics Data System (ADS)

    Burhan, I.; Azman, A. A.; Othman, R.

    2016-10-01

    An electro pneumatic trainer embedded with programmable integrated circuit (PIC) microcontroller and Visual Basic (VB) platform is fabricated as a supporting tool to existing teaching and learning process, and to achieve the objectives and learning outcomes towards enhancing the student's knowledge and hands-on skill, especially in electro pneumatic devices. The existing learning process for electro pneumatic courses conducted in the classroom does not emphasize on simulation and complex practical aspects. VB is used as the platform for graphical user interface (GUI) while PIC as the interface circuit between the GUI and hardware of electro pneumatic apparatus. Fabrication of electro pneumatic trainer interfacing between PIC and VB has been designed and improved by involving multiple types of electro pneumatic apparatus such as linear drive, air motor, semi rotary motor, double acting cylinder and single acting cylinder. Newly fabricated electro pneumatic trainer microcontroller interface can be programmed and re-programmed for numerous combination of tasks. Based on the survey to 175 student participants, 97% of the respondents agreed that the newly fabricated trainer is user friendly, safe and attractive, and 96.8% of the respondents strongly agreed that there is improvement in knowledge development and also hands-on skill in their learning process. Furthermore, the Lab Practical Evaluation record has indicated that the respondents have improved their academic performance (hands-on skills) by an average of 23.5%.

  2. Factors affecting rabbit meat consumption among Spanish university students.

    PubMed

    González-Redondo, Pedro; Mena, Yolanda; Fernández-Cabanás, Victor M

    2010-01-01

    This study investigates the rabbit meat consumption patterns among students. Results of the 342 students surveyed at the University of Seville, Spain showed that more men than women consumed rabbit meat. More students consumed wild rabbit meat than farmed rabbit meat. The practice of hunting by students or their relatives, and the raising of rabbits for self-consumption, positively influenced the proportion of students that currently consumed rabbit meat. Most of the students that had eaten rabbit meat before but are currently non-eaters do so because of the meat's organoleptic characteristics or from lack of consumption habit.

  3. Environmental sustainability comparison of a hypothetical pneumatic waste collection system and a door-to-door system

    SciTech Connect

    Punkkinen, Henna; Merta, Elina; Teerioja, Nea; Moliis, Katja; Kuvaja, Eveliina

    2012-10-15

    Highlights: Black-Right-Pointing-Pointer We compare the environmental sustainability of two MSW collection systems. Black-Right-Pointing-Pointer We evaluate pneumatic and door-to-door collection systems. Black-Right-Pointing-Pointer The greenhouse gas emissions of pneumatic collection are around three times higher. Black-Right-Pointing-Pointer System components are decisive but assumptions on electricity use are also important. Black-Right-Pointing-Pointer Pneumatic collection could provide other benefits over door-to-door system. - Abstract: Waste collection is one of the life cycle phases that influence the environmental sustainability of waste management. Pneumatic waste collection systems represent a new way of arranging waste collection in densely populated urban areas. However, limited information is available on the environmental impacts of this system. In this study, we compare the environmental sustainability of conventional door-to-door waste collection with its hypothetical pneumatic alternative. Furthermore, we analyse whether the size of the hypothetical pneumatic system, or the number of waste fractions included, have an impact on the results. Environmental loads are calculated for a hypothetical pneumatic waste collection system modelled on an existing dense urban area in Helsinki, Finland, and the results are compared to those of the prevailing, container-based, door-to-door waste collection system. The evaluation method used is the life-cycle inventory (LCI). In this study, we report the atmospheric emissions of greenhouse gases (GHG), SO{sub 2} and NO{sub x}. The results indicate that replacing the prevailing system with stationary pneumatic waste collection in an existing urban infrastructure would increase total air emissions. Locally, in the waste collection area, emissions would nonetheless diminish, as collection traffic decreases. While the electricity consumption of the hypothetical pneumatic system and the origin of electricity have a

  4. Encephalitozoon cuniculi in rabbits: Serological screening and histopathological findings.

    PubMed

    Maestrini, Giovanni; Ricci, Emanuele; Cantile, Carlo; Mannella, Riccardo; Mancianti, Francesca; Paci, Gisella; D'Ascenzi, Carlo; Perrucci, Stefania

    2017-02-01

    Serological prevalence of E. cuniculi infection was assessed in 183 rabbits from central Italy. In seropositive deceased rabbits, histopathological lesions were also evaluated. Sera from 118 rabbits from 6 intensive farms, 10 rabbits from 6 family farms, 16 rabbits from a zoo, 30 rabbits from 5 research laboratories and 9 pet rabbits from 9 different owners, were tested by an enzyme-linked immunosorbent assay. Data were statistically analysed. Tissue samples from brain and kidney of 10 deceased rabbits were formalin-fixed and subsequently analysed by histopathology and immunohistochemistry. Anti-E. cuniculi antibodies were found in 129/183 (70.5%) analysed sera. At statistical analysis, E. cuniculi seropositivity was significantly higher (p<0.05) in industrial and zoo rabbits. At histology, different degrees of pathological lesions were found in serological positive (9) deceased animals. In three rabbits deceased after showing neurological signs, the severity of the lesions was interpreted as a likely cause for their death.

  5. Additional Development and Systems Analyses of Pneumatic Technology for High Speed Civil Transport Aircraft

    NASA Technical Reports Server (NTRS)

    Englar, Robert J.; Willie, F. Scott; Lee, Warren J.

    1999-01-01

    In the Task I portion of this NASA research grant, configuration development and experimental investigations have been conducted on a series of pneumatic high-lift and control surface devices applied to a generic High Speed Civil Transport (HSCT) model configuration to determine their potential for improved aerodynamic performance, plus stability and control of higher performance aircraft. These investigations were intended to optimize pneumatic lift and drag performance; provide adequate control and longitudinal stability; reduce separation flowfields at high angle of attack; increase takeoff/climbout lift-to-drag ratios; and reduce system complexity and weight. Experimental aerodynamic evaluations were performed on a semi-span HSCT generic model with improved fuselage fineness ratio and with interchangeable plain flaps, blown flaps, pneumatic Circulation Control Wing (CCW) high-lift configurations, plain and blown canards, a novel Circulation Control (CC) cylinder blown canard, and a clean cruise wing for reference. Conventional tail power was also investigated for longitudinal trim capability. Also evaluated was unsteady pulsed blowing of the wing high-lift system to determine if reduced pulsed mass flow rates and blowing requirements could be made to yield the same lift as that resulting from steady-state blowing. Depending on the pulsing frequency applied, reduced mass flow rates were indeed found able to provide lift augmentation at lesser blowing values than for the steady conditions. Significant improvements in the aerodynamic characteristics leading to improved performance and stability/control were identified, and the various components were compared to evaluate the pneumatic potential of each. Aerodynamic results were provided to the Georgia Tech Aerospace System Design Lab. to conduct the companion system analyses and feasibility study (Task 2) of theses concepts applied to an operational advanced HSCT aircraft. Results and conclusions from these

  6. TECHNICAL DESIGN NOTE: Identification of the flow-rate characteristics of a pneumatic valve by the instantaneous polytropic exponent

    NASA Astrophysics Data System (ADS)

    Qian, Ye; Xiang, Meng Guo

    2008-05-01

    A novel method of the identification of the flow-rate characteristics of pneumatic valves using the instantaneous polytropic exponents during a discharge process is proposed. The method can determine the sonic conductance C, the critical pressure ratio b and the subsonic index ms of a pneumatic valve with a single discharge process. The method is based on a new hybrid natural and forced convection heat transfer criterion model. The procedure of the identification of the flow-rate characteristics of the pneumatic valve has been derived. Some examples of the calculation are given and the results are graphically illustrated. Experimental results show that the model has good accuracy and universality.

  7. A biomechanical study of two postoperative prostheses for transtibial amputees: a custom-molded and a prefabricated adjustable pneumatic prosthesis.

    PubMed

    Boucher, Henry R; Schon, Lew C; Parks, Brent; Kleeman, Jay; Dunn, Warren R; Badekas, Thanos; Noll, Kenneth; Melamed, Eyal

    2002-05-01

    We evaluated an adjustable pneumatic prefabricated prosthesis and a rigid custom-molded prosthesis for immediate postoperative use. Twelve transtibial amputations were performed on cadaver limbs. Differential variable reluctance transducers were placed subcutaneously across the wound edge medially and laterally. The limbs were then placed in either the pneumatic prosthesis (five limbs) or the rigid prosthesis (seven limbs). The specimens underwent static and cyclic loading to simulate weight bearing. The strain readings for static and cyclic loading were greater in the rigid prosthetic group. Only the mean medial strain measurement after cyclic loading was statistically significant. The results demonstrate that the pneumatic prosthesis places less strain across the wound than a rigid prosthesis.

  8. Pneumatic active suspension system for a one-wheel car model using fuzzy reasoning and a disturbance observer.

    PubMed

    Yoshimura, Toshio; Takagi, Atsushi

    2004-09-01

    This paper presents the construction of a pneumatic active suspension system for a one-wheel car model using fuzzy reasoning and a disturbance observer. The one-wheel car model can be approximately described as a nonlinear two degrees of freedom system subject to excitation from a road profile. The active control is composed of fuzzy and disturbance controls, and functions by actuating a pneumatic actuator. A phase lead-lag compensator is inserted to counter the performance degradation due to the delay of the pneumatic actuator. The experimental result indicates that the proposed active suspension improves much the vibration suppression of the car model.

  9. Bobcat attack on a cottontail rabbit

    USGS Publications Warehouse

    Biggins, D.E.; Biggins, D.M.

    2006-01-01

    We observed an attack by a bobcat (Lynx rufus) on a cottontail rabbit (Sylvilagus) that involved stealthy approach by the cat for >1 h, followed by a 12.3-s chase covering 116.0 m for the cat and 128.4 m for the rabbit. During the chase, the route of the cat from starting point to kill site was more direct than the semi-circular route of the rabbit. Stride lengths for the cat and total distance covered by the chase were longer than those previously reported for bobcats.

  10. Antiradiation Vaccine: Technology Development Of Prophylaxis, Prevention And Treatment Of Biological Consequences And Complications After Neutron Irradiation.

    NASA Astrophysics Data System (ADS)

    Popov, Dmitri; Maliev, Slava; Jones, Jeffrey

    irradiation generated in a canal of Research Reactor BBP-M and BBP-M. Mixed neutron beam contained 95% of fast neutron irradiation and 5% of gamma-irradiation. Neutron energy - 1.98 - 2.30 Me V energy. Dose - 10.7 Gy., 0.22 Gy-min. Scheme of experiments: Rabbits from all groups were irradiated in a canal of Research Reactor together. Group A: control-5 rabbits; Group B:placebo-5 rabbits; Group C: radioprotectant Cystamine (50 mg-kg)-5 rabbits, 15 minutes before irradiation Group D:Radio-protectant Mexamine (10 mg-kg)-5 rabbits { 15 minutes before irradiation; Group E: Antiradiation Vaccine: subcutaneus administration or I-M - 2 ml of active substance , 20 days before irradiation. Results: Control Group A - 100% mortality within the next two hours after neutron irradiation with clinical symptoms of acute cerebrovascular syndrome. Group B - 100% mortality less than two hours following irradiation. Group C - 100% mortality within 8-10 hours after irradiation. Group D - 100% mortality within 8-11 hours after irradiation. In Groups A - D the development of extremely severe form of Acute Radiation Cerebrovascular Syndrome produced rapid death. Group E - 100% mortality within 240 hours ( 9|10 days) following neutron irradiation with animals exhibiting cardiovascular, cerebrovascular and gastrointestinal clinical symptoms. Discussion: A pre-irradiation vaccination with Antiradiation Vaccine is effective against mild and even high doses of neutron radiation. Vaccination with antiradiation Vaccine prolonged survival time of rabbits, exposed to a high dose LD100, of neutron radiation: from two hours (control) up to 11 days. We also postulate that radiation toxins,isolated from lymph of gamma-irradiated animals are likely similar to structure of radiation toxins circulated in blood and lymph of neutron irradiated animals. Toxico-kinetics and toxico-dynamics of radiation toxins of after neutron-irradiation were quite unique and distinguished from different types of radiation

  11. Protecting fibrinogen with rutin during UVC irradiation for viral inactivation.

    PubMed

    Marx, G; Mou, X; Freed, R; Ben-Hur, E; Yang, C; Horowitz, B

    1996-04-01

    Fibrinogen solutions were irradiated with UVC (254 nm) to inactivate contaminating viruses. In order to protect fibrinogen during UVC irradiation, 0.5 mM rutin was added prior to UVC exposure and subsequently removed during processing. Viral kill by 0.1 J/cm2 UVC resulted in the following inactivation values (log 10): non-lipid-enveloped viruses: Parvo > or = 5.5; encephalomyocarditis virus > or = 6.5; hepatitis A virus > or = 6.5: lipid-enveloped viruses: human immunodeficiency virus > or = 5.7; vesicular stomatitis virus > or = 5.7. Fibrinogen irradiated with 0.5 mM rutin did not significantly differ from unirradiated material in terms of clot time and breaking strength. In the absence of rutin, UVC irradiation of fibrinogen at similar fluence led to loss of solubility, increased clot time and the cleavage of fibrino-peptides that reacted with dinitrophenyl hydrazine as a test for ketonic carbonyl groups. High-performance liquid chromatography and mass spectrometry data showed that rutin exposed to UVC formed numerous breakdown, oxidation and combinational products. Experiments with 3H-rutin showed that after UVC irradiation, subsequent processing by a C18 resin and alcohol precipitation removed > 99% rutin, representing < 10 ppm rutin in the final fibrinogen preparations. Residual 3H-rutin was not covalently bonded to the fibrinogen. Immunochemical studies with rabbit antisera to UVC irradiated (with rutin) fibrinogen showed the absence of neoimmungens. By all measures, rutin prevents fibrinogen degradation during virucidal UVC irradiation.

  12. Damage to the photoreceptor cells of the rabbit retina from 56Fe ions: effect of age at exposure, 1

    NASA Technical Reports Server (NTRS)

    Williams, G. R.; Lett, J. T.; Chatterjee, A. (Principal Investigator)

    1996-01-01

    Optic and proximate tissues of New Zealand white (NZW) rabbits at ages (approximately 3.5 years) near the middle of their median lifespan (5-7 years) were given 0.5-3.5 Gy of 465 MeV u-1 56Fe ions in the Bragg plateau region of energy deposition at a linear energy transfer (LET infinity) of 220 +/- 31 keV micrometer-1. Dose-dependent losses of retinal photoreceptor cells (rods) occurred until 1-2 years after irradiation, the period of this interim report. Similar cumulative losses of photoreceptor cells were seen during the period 1-2 years post-irradiation for rabbits given comparable exposures when young (6-9 weeks old). Since losses of photoreceptor cells at early times had not been determined previously, the current experiment, which was designed to simulate the responses of mature astronauts, redressed that deficiency.

  13. Metabolism of hydroanthracenones in rabbits

    PubMed Central

    Robertson, J. S.; Dunstan, P. J.

    1972-01-01

    1. The metabolism of 1-oxo-octahydro- and 2- and 9-oxoperhydro-anthracenes was investigated in rabbits. All compounds increased the urinary glucuronide content. 2. The 1-oxo and 2-oxo compounds were reduced to the corresponding alcohols whereas the 9-oxo compound was hydroxylated. 3. The reduction in vitro of these compounds and related ketones was investigated with three different enzyme systems (liver alcohol dehydrogenase, hydroxy steroid dehydrogenase, aromatic aldehyde–ketone reductase) in an attempt to explain the results in vivo. 4. Successful reduction of many ketones with aromatic aldehyde–ketone reductase suggests that the kidney may be of importance in the reduction in vivo of certain cyclic carbonyl compounds. PMID:5073736

  14. Immunobiological effect of bitemporal exposure of rabbits to microwaves

    SciTech Connect

    Bogolyubov, V.M.; Pershin, S.B.; Frenkel', I.D.; Sidorov, V.D.; Galenchik, A.I.; Ponomarev, Yu.T.; Bobkova, A.S.; Kuz'min, S.N.; Moshiashvili, I.Ya.; Kozlova, N.N.; Korovkina, E.G.; Agibalov, Yu.V.

    1987-01-01

    The authors investigate the effects of microwave radiation on the immunological behavior of the thyroid and various hormones of rabbits. Irradiation was carried out on the heads of the animals. They were then divided into four groups depending on the period of exposure. The number of hemolysis-forming cells against sheep red blood cells and the concentration of serum immunoglobulins were determined. Levels of TSH, triiodothyronine, thyroxine, testosterone and prostaglandins in serum or blood plasma were determined by radioimmunoassay and the concentration of total 11-hydroxycorticosteroids in the adrenals and plasma were determined by fluorimetry. Microwave radiation of the temporo-parietal region of the head was found to decrease the number of background hemolysis-forming cells. An increase in glucocorticoid function was recorded. Thyroid function was depressed. The plasma 11-hydroxycorticosteroid level was significantly raised. It is concluded in general that microwave irradiation leads to activation of the hypothalamo-hypophyseo-adrenal system with consequent enhancement of the glucocorticoid function of the adrenal cortex and depression of thyroid function.

  15. [Analysis of pulsed bioelectric activity of rabbit cerebral cortex in response to low-intensity microwave radiation].

    PubMed

    Luk'ianova, S N; Monseeva, N V

    1998-01-01

    In experiments on 22 rabbits the influence of a pulse microwave irradiation on extracellular activity of separate nervous cells of sensorimotori and occipital areas of a cortex brain is shown. The reaction could consist in activation or in braking frequency of the discharges, that was connected to frequency impulsation in an initial background. The researched mode of a microwave irradiation (1.5 GHz, duration of a pulsed-0.4 microsecond, frequency of their recurrence 1000 Hz, DFEpulsed-300 microW/sm2) had a corrigizing action.

  16. Investigation and comparison of performance of effervescent and standard pneumatic atomizer intended for soluble aqueous coating.

    PubMed

    Nielsen, Anne Flachs; Poul, Bertelsen; Kristensen, Henning Gjelstrup; Kristensen, Jakob; Hovgaard, Lars

    2006-01-01

    Effervescent atomizers belong to the group of internal mixing atomizers. The effervescent approach might be a potential alternative to traditional atomization techniques, e.g., for applications where low atomization air consumption is advantageous In this paper, performance of one proposed design of the effervescent atomizer is investigated and compared to that of a standard pneumatic atomizer. The purpose of the comparison is to evaluate the actual potential of the specific effervescent atomizer in pharmaceutical relevant aqueous coating applications. Aqueous solutions of Hypromellose 5 as well as Povidone K-90F were characterized in terms of rheological properties and surface tension. Solutions were atomized by means of a standard Schlick pneumatic atomizer as well as a customized inside-out type effervescent atomizer. Spray droplet size distributions were recorded by a Spraytec instrument. Increased shear viscosity in the range 24-836 mPa.s had a modest effect on spray mean diameters for pneumatic sprays of the Newtonian solutions of Hypromellose 5. In contrast, mean droplet diameters increased by a factor of 3-5 in pneumatic sprays of Povidone K-90F solutions 11-175 mPa.s in viscosity, where non-Newtonian behavior was observed. Further, sprays of all solutions of Povidone K-90F have considerably larger mean droplet size. The effervescent atomizer atomized low viscosity solutions of Povidone K-90F more efficiently than Hypromellose 5 solutions of corresponding shear viscosity. However, atomization of high viscosity Povidone K-90F results in a coarser spray than that of the corresponding Hypromellose 5 solution. Viscosity, visco-elasticity, and surface tension of solutions all seem to affect atomization efficiency. The pneumatic atomizer was not sensitive to changes in airflow above 8.4 kg/h and liquid flow only had a considerable effect at suboptimal air flows. In its current design the effervescent atomizer improved efficiency throughout the investigated range

  17. Rabbit haemorrhagic disease: field epidemiology and the management of wild rabbit populations.

    PubMed

    Cooke, B D

    2002-08-01

    Rabbit haemorrhagic disease (RHD) has become established in wild rabbit populations throughout Western Europe, Australia and New Zealand. The abundance of wild rabbits has been significantly reduced, particularly in drier areas of southern Spain, inland Australia and South Island New Zealand. A detailed knowledge of the epidemiology of RHD is essential for the management of the disease in natural rabbit populations, either to rebuild or to control populations. When RHD first spread among naive wild rabbits, epidemiological studies provided unique information on the rate of spread, the possible role of insect vectors in transmission, and the correlation between the impact of disease on populations and climatic variables. Current research shows a consistent pattern of epidemiology between Europe and Australasia. Typically, the most severe epizootics of RHD occur among young sub-adult rabbits which have lost age-related resilience and maternal antibodies. However, the timing of these outbreaks reflects climatic variables that determine the breeding season of the rabbits and the periods when RHD virus (RDHV) is most likely to persist and spread. Further factors that may complicate epidemiology include the possibility that non-pathogenic RHDV-like viruses are present in natural rabbit populations. Additionally, the question of how the virus persists from year to year remains unresolved; persistence in carrier rabbits is a possibility. Understanding of the epidemiology of RHD is now sufficiently advanced to consider the possibility of manipulating rabbit populations to alter the epidemiological pattern of RHD and thereby maximise or minimise the mortality caused by the disease. Altering the epidemiology of RHD in this manner would assist the management of wild rabbit populations either for conservation or pest control purposes.

  18. Genomic Analysis of Companion Rabbit Staphylococcus aureus

    PubMed Central

    Holmes, Mark A.; Harrison, Ewan M.; Fisher, Elizabeth A.; Graham, Elizabeth M.; Parkhill, Julian; Foster, Geoffrey; Paterson, Gavin K.

    2016-01-01

    In addition to being an important human pathogen, Staphylococcus aureus is able to cause a variety of infections in numerous other host species. While the S. aureus strains causing infection in several of these hosts have been well characterised, this is not the case for companion rabbits (Oryctolagus cuniculus), where little data are available on S. aureus strains from this host. To address this deficiency we have performed antimicrobial susceptibility testing and genome sequencing on a collection of S. aureus isolates from companion rabbits. The findings show a diverse S. aureus population is able to cause infection in this host, and while antimicrobial resistance was uncommon, the isolates possess a range of known and putative virulence factors consistent with a diverse clinical presentation in companion rabbits including severe abscesses. We additionally show that companion rabbit isolates carry polymorphisms within dltB as described as underlying host-adaption of S. aureus to farmed rabbits. The availability of S. aureus genome sequences from companion rabbits provides an important aid to understanding the pathogenesis of disease in this host and in the clinical management and surveillance of these infections. PMID:26963381

  19. Determination of variables for air distribution system with elastic valve for down-the-hole pneumatic hammer

    NASA Astrophysics Data System (ADS)

    Primychkin, AYu; Kondratenko, AS; Timonin, VV

    2017-02-01

    The air distribution system of down-the-hole pneumatic hammer 105 mm in diameter is updated to enhance drilling efficiency. The design model of the down-the-hole pneumatic hammer is constructed in ITI SimulationX environment. The basic variables of the air distribution system with an elastic valve are determined so that to ensure increased impact energy at the limited pre-impact velocity and the same machine size.

  20. Air space proportion in pterosaur limb bones using computed tomography and its implications for previous estimates of pneumaticity.

    PubMed

    Martin, Elizabeth G; Palmer, Colin

    2014-01-01

    Air Space Proportion (ASP) is a measure of how much air is present within a bone, which allows for a quantifiable comparison of pneumaticity between specimens and species. Measured from zero to one, higher ASP means more air and less bone. Conventionally, it is estimated from measurements of the internal and external bone diameter, or by analyzing cross-sections. To date, the only pterosaur ASP study has been carried out by visual inspection of sectioned bones within matrix. Here, computed tomography (CT) scans are used to calculate ASP in a small sample of pterosaur wing bones (mainly phalanges) and to assess how the values change throughout the bone. These results show higher ASPs than previous pterosaur pneumaticity studies, and more significantly, higher ASP values in the heads of wing bones than the shaft. This suggests that pneumaticity has been underestimated previously in pterosaurs, birds, and other archosaurs when shaft cross-sections are used to estimate ASP. Furthermore, ASP in pterosaurs is higher than those found in birds and most sauropod dinosaurs, giving them among the highest ASP values of animals studied so far, supporting the view that pterosaurs were some of the most pneumatized animals to have lived. The high degree of pneumaticity found in pterosaurs is proposed to be a response to the wing bone bending stiffness requirements of flight rather than a means to reduce mass, as is often suggested. Mass reduction may be a secondary result of pneumaticity that subsequently aids flight.

  1. Air Space Proportion in Pterosaur Limb Bones Using Computed Tomography and Its Implications for Previous Estimates of Pneumaticity

    PubMed Central

    Martin, Elizabeth G.; Palmer, Colin

    2014-01-01

    Air Space Proportion (ASP) is a measure of how much air is present within a bone, which allows for a quantifiable comparison of pneumaticity between specimens and species. Measured from zero to one, higher ASP means more air and less bone. Conventionally, it is estimated from measurements of the internal and external bone diameter, or by analyzing cross-sections. To date, the only pterosaur ASP study has been carried out by visual inspection of sectioned bones within matrix. Here, computed tomography (CT) scans are used to calculate ASP in a small sample of pterosaur wing bones (mainly phalanges) and to assess how the values change throughout the bone. These results show higher ASPs than previous pterosaur pneumaticity studies, and more significantly, higher ASP values in the heads of wing bones than the shaft. This suggests that pneumaticity has been underestimated previously in pterosaurs, birds, and other archosaurs when shaft cross-sections are used to estimate ASP. Furthermore, ASP in pterosaurs is higher than those found in birds and most sauropod dinosaurs, giving them among the highest ASP values of animals studied so far, supporting the view that pterosaurs were some of the most pneumatized animals to have lived. The high degree of pneumaticity found in pterosaurs is proposed to be a response to the wing bone bending stiffness requirements of flight rather than a means to reduce mass, as is often suggested. Mass reduction may be a secondary result of pneumaticity that subsequently aids flight. PMID:24817312

  2. Environmental sustainability comparison of a hypothetical pneumatic waste collection system and a door-to-door system.

    PubMed

    Punkkinen, Henna; Merta, Elina; Teerioja, Nea; Moliis, Katja; Kuvaja, Eveliina

    2012-10-01

    Waste collection is one of the life cycle phases that influence the environmental sustainability of waste management. Pneumatic waste collection systems represent a new way of arranging waste collection in densely populated urban areas. However, limited information is available on the environmental impacts of this system. In this study, we compare the environmental sustainability of conventional door-to-door waste collection with its hypothetical pneumatic alternative. Furthermore, we analyse whether the size of the hypothetical pneumatic system, or the number of waste fractions included, have an impact on the results. Environmental loads are calculated for a hypothetical pneumatic waste collection system modelled on an existing dense urban area in Helsinki, Finland, and the results are compared to those of the prevailing, container-based, door-to-door waste collection system. The evaluation method used is the life-cycle inventory (LCI). In this study, we report the atmospheric emissions of greenhouse gases (GHG), SO(2) and NO(x). The results indicate that replacing the prevailing system with stationary pneumatic waste collection in an existing urban infrastructure would increase total air emissions. Locally, in the waste collection area, emissions would nonetheless diminish, as collection traffic decreases. While the electricity consumption of the hypothetical pneumatic system and the origin of electricity have a significant bearing on the results, emissions due to manufacturing the system's components prove decisive.

  3. Commercial food irradiation

    SciTech Connect

    Black, E.F.; Libby, L.M.

    1983-06-01

    Food irradiation is discussed. Irradiation exposes food to gamma rays from a cobalt-60 or a cesium-137 source, or to high-energy electrons emitted by an electron accelerator. A major advantage is that food can be packaged either before or after treatment. FDA regulations with regard to irradiation are discussed. Comments on an 'Advance Notice' on irradiation, published by the FDA in 1981 are summarized.

  4. Effect of laser soldering irradiation on covalent bonds of pure collagen.

    PubMed

    Constantinescu, Mihai A; Alfieri, Alex; Mihalache, George; Stuker, Florian; Ducray, Angélique; Seiler, Rolf W; Frenz, Martin; Reinert, Michael

    2007-03-01

    Laser tissue welding and soldering is being increasingly used in the clinical setting for defined surgical procedures. The exact induced changes responsible for tensile strength are not yet fully investigated. To further improve the strength of the bonding, a better understanding of the laser impact at the subcellular level is necessary. The goal of this study was to analyze whether the effect of laser irradiation on covalent bonding in pure collagen using irradiances typically applied for tissue soldering. Pure rabbit and equine type I collagen were subjected to laser irradiation. In the first part of the study, rabbit and equine collagen were compared using identical laser and irradiation settings. In the second part of the study, equine collagen was irradiated at increasing laser powers. Changes in covalent bonding were studied indirectly using the sodium dodecylsulfate polyacrylamide gel electrophoresis (SDS-PAGE) technique. Tensile strengths of soldered membranes were measured with a calibrated tensile force gauge. In the first experiment, no differences between the species-specific collagen bands were noted, and no changes in banding were found on SDS-PAGE after laser irradiation. In the second experiment, increasing laser irradiation power showed no effect on collagen banding in SDS-PAGE. Finally, the laser tissue soldering of pure collagen membranes showed virtually no determinable tensile strength. Laser irradiation of pure collagen at typical power settings and exposure times generally used in laser tissue soldering does not induce covalent bonding between collagen molecules. This is true for both rabbit and equine collagen proveniences. Furthermore, soldering of pure collagen membranes without additional cellular components does not achieve the typical tensile strength reported in native, cell-rich tissues. This study is a first step in a better understanding of laser impact at the molecular level and might prove useful in engineering of combined

  5. Massive Pulmonary Calculi Embolism: A Novel Complication of Pneumatic Lithotripsy: A Case Report.

    PubMed

    Zhang, Lin; Zhou, Yiwu

    2015-07-01

    Pneumatic lithotripsy is a minimally invasive technique mainly for the treatment of urinary staghorn stones. Previous literatures have reported some therapeutic complications during or after this procedure, but calculi embolism has not been mentioned before.We report here a fatal case of calculi-induced pulmonary embolism in an adult woman who underwent pneumatic lithotripsy. An autopsy did not reveal any evidence of pulmonary embolism. However, light microscopy revealed noticeable presence of calculi in pulmonary arterioles and capillaries, as evidenced by environmental scanning electron microscope and energy dispersive X-ray analysis. The primary determinants of calculi embolism include intrarenal pressure, and volume and viscosity of the calculi fragments formation. Vascular intravasation of smashed calculi might increase pulmonary vascular resistance and hypoxemia and decrease cardiac output.This case report intends to provide information for clinicians to consider the probability of intraoperative calculi embolism during lithotripsies when patients develop typical symptoms of acute pulmonary embolism.

  6. Management of retinal detachment in block related globe perforation with pneumatic retinopexy.

    PubMed

    Rishi, Karandeep; Venkatesh, Pradeep; Garg, Satpal P

    2013-03-01

    Retinal detachment after ocular perforation related to local anesthesia is a common complication, which is usually associated with a poor prognosis despite complex vitreoretinal surgical procedures. We report a case of 62-year-old male with cataract surgery done 4 weeks back with nasal retinal detachment with a posterior break. Pneumatic retinopexy was performed and laser barrage of the breaks was done the next day when the retina got attached. A vision of 20/30 was achieved at the end of 2 months. To the best of our knowledge, this is a first case report in literature where pneumatic retinopexy was used to manage a retinal detachment caused by block-related perforation.

  7. Transient Analysis of Pressurization and Pneumatic Subsystems of the X-34 Main Propulsion System

    NASA Technical Reports Server (NTRS)

    Hedayat, A.; Knight, K. C.; Chamption, R. H., Jr.; Kennedy, Jim W. (Technical Monitor)

    2000-01-01

    Transient models for the pressurization, vent/relief, and pneumatic subsystems of the X-34 Main Propulsion System are presented and simulation of their operation within prescribed requirements are provided. First, using ROCket Engine Transient Simulation (ROCETS) program, pressurization subsystem operation was simulated and helium requirements and the ullage thermodynamic condition within each propellant tank were calculated. Then, Overpressurization scenarios of propellant tanks and the response of vent/relief valves were evaluated using ROCETS simulation of simultaneous operation of the pressurization and vent/relief subsystems by incorporating the valves data into the model. Finally, the ROCETS simulation of in-flight operation of pneumatic subsystem predicted the overall helium consumption, Inter-Propellant Seal (IPS) purge flowrate and thermodynamic conditions, and Spin Start power.

  8. A comparison of hydraulic, pneumatic, and electro-mechanical actuators for general aviation flight controls

    NASA Technical Reports Server (NTRS)

    Roskam, J.; Rice, M.; Eysink, H.

    1979-01-01

    Mathematical models for electromechanical (EM), pneumatic and hydraulic actuations are discussed. It is shown that EM and hydraulic actuators provide better and faster time responses than pneumatic actuators but EM actuators utilizing the recently developed samarium-cobalt technology have significant advantages in terms of size, weight and power requirements. In terms of ease and flexibility of installation EM actuators apparently have several advantages over hydraulic actuators, and cost is a primary reason for the popularity of EM actuation for secondary control function since no additional systems need to be added to the aircraft. While new rare earth magnets are currently in developmental stage, costs are relatively high; but continued research should bring prices down.

  9. Development of a Pneumatic Robot for MRI-guided Transperineal Prostate Biopsy and Brachytherapy: New Approaches.

    PubMed

    Song, Sang-Eun; Cho, Nathan B; Fischer, Gregory; Hata, Nobuhito; Tempany, Clare; Fichtinger, Gabor; Iordachita, Iulian

    2010-07-15

    Magnetic Resonance Imaging (MRI) guided prostate biopsy and brachytherapy has been introduced in order to enhance the cancer detection and treatment. For the accurate needle positioning, a number of robotic assistants have been developed. However, problems exist due to the strong magnetic field and limited workspace. Pneumatically actuated robots have shown the minimum distraction in the environment but the confined workspace limits optimal robot design and thus controllability is often poor. To overcome the problem, a simple external damping mechanism using timing belts was sought and a 1-DOF mechanism test result indicated sufficient positioning accuracy. Based on the damping mechanism and modular system design approach, a new workspace-optimized 4-DOF parallel robot was developed for the MRI-guided prostate biopsy and brachytherapy. A preliminary evaluation of the robot was conducted using previously developed pneumatic controller and satisfying results were obtained.

  10. Mass flow measurement of pneumatically conveyed solids using electrical capacitance tomography

    NASA Astrophysics Data System (ADS)

    Sun, Meng; Liu, Shi; Lei, Jing; Li, Zhihong

    2008-04-01

    This paper describes a measurement system for mass flow measurement in a pneumatic pipeline. The system mainly consists of a volumetric concentration sensor and a velocity sensor. The concentration sensor is an electrical capacitance sensor which has eight electrodes; the velocity sensor is based on cross-correlating two signals derived from a pair of capacitance sensors. A cyclone is employed in this system where the sensors are placed in order to compensate the inhomogeneity of the sensor sensitivity. Experimental results obtained on a pneumatic conveyer circulating coal ash demonstrate that this system is capable of detecting various velocity profiles and solids distributions and providing an absolute mass flow rate of solids within a good agreement with the reference reading from load cells.

  11. Pneumatic-Controlled Fluidic Microdevices for Executing NOT, NOR, and NAND Logic Functions

    NASA Astrophysics Data System (ADS)

    Chang, Hsing-Cheng; Tsou, Chingfu; Lai, Chi-Chih; Huang, Ming-Che

    2008-03-01

    Novel pneumatic-controlled logic microdevices based on a microelectromechanical system (MEMS) compatible process and microfluidic control technology have been developed for executing the universal basic logic functions of NOT, NOR, and NAND. The main fabrication processes for the logic microdevices include anisotropic silicon bulk etching, silicone rubber membrane formation, wafer bonding and packaging. The dynamic characteristics and pneumatic-controlled performance of the elastic membranes have been measured using an equipped fluidic instrument, which indicates their potential application to safety monitoring for preventing electric-induced disasters. All logic functions of the microdevices have been demonstrated to correspond exactly to the related truth tables. The newly developed logic microdevices are capable of controlling a liquid or gas system with high sensitivity in a wide dynamic range, and with strong immunity from temperature fluctuations.

  12. Semi-autonomous liquid handling via on-chip pneumatic digital logic.

    PubMed

    Nguyen, Transon V; Duncan, Philip N; Ahrar, Siavash; Hui, Elliot E

    2012-10-21

    This report presents a liquid-handling chip capable of executing metering, mixing, incubation, and wash procedures largely under the control of on-board pneumatic circuitry. The only required inputs are four static selection lines to choose between the four machine states, and one additional line for power. State selection is simple: constant application of vacuum to an input causes the device to execute one of its four liquid handling operations. Programmed control of 31 valves, including fast coordinated cycling for peristaltic pumping, is accomplished by pneumatic digital logic circuits built out of microfluidic valves and channels rather than electronics, eliminating the need for the off-chip control machinery that is typically required for integrated microfluidics.

  13. Characterization of a pneumatic balloon actuator for use in refreshable Braille displays.

    PubMed

    Fan, Richard E; Feinman, Adam M; Wottawa, Christopher; King, Chih-Hung; Franco, Miguel L; Dutson, Erik P; Grundfest, Warren S; Culjat, Martin O

    2009-01-01

    Many existing refreshable Braille display technologies are costly or lack robust performance. A process has been developed to fabricate consistent and reliable pneumatic balloon actuators at low material cost, using a novel manufacturing process. This technique has been adapted for use in refreshable Braille displays that feature low power consumption, ease of manufacture and small form factor. A prototype refreshable cell, conforming to American Braille standards, was developed and tested. The cell was fabricated from molded PDMS to form balloon actuators with a spin-coated silicone film, and fast pneumatic driving elements and an electronic control system were developed to drive the Braille dots. Perceptual testing was performed to determine the feasibility of the approach using a single blind human subject. The subject was able to detect randomized Braille letters rapidly generated by the actuator with 100% character detection accuracy.

  14. Investigation of work parameters of SI engine dedicated to energetics aggregates with pneumatic injection system

    NASA Astrophysics Data System (ADS)

    Marek, W.; Śliwiński, K.

    2016-09-01

    The article presents the possibilities of alternative fuel combustion in the engine four- stroke spark ignition engines. Power of the motor was carried out pneumatic fuel injection system using a hot gas developed by Prof. Stanislaw Jarnuszkiewicz. Presented made the position of the measuring system with the power and results. The engine experimental at the time of the study was powered by a blend of alcohol and gasoline. The main aim of the study was the question of control fuel dosage, taking into account the energy needs of forcing the engine load. During the tests carried load characteristics control the motor using the power control quality. Another issue was the elimination of penetration of fuel to the engine lubrication system, a problem occurred in the initial study on the issue of the pneumatic fuel injection using the hot exhaust gases. In summary we present the findings of this phase of the study.

  15. Experimental research on the behavior of the pneumatic transport of fine-grained iron

    NASA Astrophysics Data System (ADS)

    Andrei, V.; Hritac, M.; Constantin, N.; Dobrescu, C.

    2017-01-01

    Mixed injection of fine-grained iron ore and pulverized coal in the furnace, involves determining the behavior of these materials during pneumatic transport in a dense state through the pipe and setting possibilities for adjusting the flow rate of material transported with the corresponding values of the process. Parameters of the pneumatic transport were determined for the main types of iron ore and chalk used in Arcelor Mittal Galati. Outside the intended purpose of injecting iron ore and flux, it was considered also the experimental check of the possibility for injecting ilmenite in the furnace for crucible protection purpose. The possibility of injecting cinder mill into the furnace was also considered. Injecting cinder could be taken into account for the recycling of ferrous waste in the furnace, also as additive for intensifying the combustion process around the tuyeres.

  16. Development of a Pneumatic Robot for MRI-guided Transperineal Prostate Biopsy and Brachytherapy: New Approaches

    PubMed Central

    Song, Sang-Eun; Cho, Nathan B.; Fischer, Gregory; Hata, Nobuhito; Tempany, Clare; Fichtinger, Gabor; Iordachita, Iulian

    2011-01-01

    Magnetic Resonance Imaging (MRI) guided prostate biopsy and brachytherapy has been introduced in order to enhance the cancer detection and treatment. For the accurate needle positioning, a number of robotic assistants have been developed. However, problems exist due to the strong magnetic field and limited workspace. Pneumatically actuated robots have shown the minimum distraction in the environment but the confined workspace limits optimal robot design and thus controllability is often poor. To overcome the problem, a simple external damping mechanism using timing belts was sought and a 1-DOF mechanism test result indicated sufficient positioning accuracy. Based on the damping mechanism and modular system design approach, a new workspace-optimized 4-DOF parallel robot was developed for the MRI-guided prostate biopsy and brachytherapy. A preliminary evaluation of the robot was conducted using previously developed pneumatic controller and satisfying results were obtained. PMID:21399734

  17. Feasibility and testing of lighweight, energy efficient, additive manufactured pneumatic control valve

    SciTech Connect

    Love, Lonnie J.; Mell, Ellen

    2015-02-01

    AeroValve s innovative pneumatic valve technology recycles compressed air through the valve body with each cycle of the valve, and was reported to reduce compressed air requirements by an average of 25% 30%.This technology collaboration project between ORNL and Aerovalve confirms the energy efficiency of valve performance. Measuring air consumption per work completed, the AeroValve was as much as 85% better than the commercial Festo valve.

  18. A Randomized Controlled Trial of Massage and Pneumatic Compression for Ultramarathon Recovery.

    PubMed

    Hoffman, Martin D; Badowski, Natalie; Chin, Joseph; Stuempfle, Kristin J

    2016-05-01

    Study Design Randomized controlled trial. Background Postexercise recovery techniques are widely used, but little research has examined their effectiveness. Objectives To examine the effectiveness of massage and pneumatic compression on recovery from a 161-km ultramarathon. Methods Participants in the 2015 161-km Western States Endurance Run were randomized to a 20-minute postrace intervention of massage, intermittent sequential pneumatic compression, or supine rest. Each subject completed two 400-m runs at maximum speed before the race and on days 3 and 5 after the race, and also provided muscle pain and soreness ratings and overall muscular fatigue scores before and for 7 days after the race. Results Among the 72 runners who finished the race and completed the study, comparison among intervention groups revealed no significant group or interaction effect on 400-m run time, but there was a significant (P<.0001) time effect. Immediately posttreatment, massage resulted in lower muscle pain and soreness ratings compared with the supine-rest control condition (P<.0001), while both massage (P<.0001) and pneumatic compression (P<.01) resulted in lower overall muscular fatigue scores compared with the control group. There were no significant differences between groups in any outcome 1 to 7 days after the race. Conclusion Single 20-minute sessions of postrace massage and intermittent sequential pneumatic compression provide some immediate subjective benefit. There is no evidence, however, that such treatments provide extended subjective or functional benefits of clinical importance. The trial was registered at www.clinicaltrials.gov (NCT02530190). Level of Evidence Therapy, level 1b. J Orthop Sports Phys Ther 2016;46(5):320-326. Epub 23 Mar 2016. doi:10.2519/jospt.2016.6455.

  19. NK-1 Removable Cryogenic Shroud (A Study of the Bimba Pneumatic Cylinder)

    SciTech Connect

    Anderson, K; Stefanescu, D

    2003-02-07

    The Mark 1 Cryostat requires a cryogenic shroud that must be retracted immediately before firing the NIF laser. This paper evaluates a pneumatic cylinder that has been chosen to open and close the shroud. After a variety of motion control and vacuum compatibility experiments, we concluded that the Bimba feedback control cylinder may be used to retract the shroud with certain modifications to its control system and additional rod seals.

  20. Development of Pneumatic Aerodynamic Devices to Improve the Performance, Economics, and Safety of Heavy Vehicles

    SciTech Connect

    Robert J. Englar

    2000-06-19

    Under contract to the DOE Office of Heavy Vehicle Technologies, the Georgia Tech Research Institute (GTRI) is developing and evaluating pneumatic (blown) aerodynamic devices to improve the performance, economics, stability and safety of operation of Heavy Vehicles. The objective of this program is to apply the pneumatic aerodynamic aircraft technology previously developed and flight-tested by GTRI personnel to the design of an efficient blown tractor-trailer configuration. Recent experimental results obtained by GTRI using blowing have shown drag reductions of 35% on a streamlined automobile wind-tunnel model. Also measured were lift or down-load increases of 100-150% and the ability to control aerodynamic moments about all 3 axes without any moving control surfaces. Similar drag reductions yielded by blowing on bluff afterbody trailers in current US trucking fleet operations are anticipated to reduce yearly fuel consumption by more than 1.2 billion gallons, while even further reduction is possible using pneumatic lift to reduce tire rolling resistance. Conversely, increased drag and down force generated instantaneously by blowing can greatly increase braking characteristics and control in wet/icy weather due to effective ''weight'' increases on the tires. Safety is also enhanced by controlling side loads and moments caused on these Heavy Vehicles by winds, gusts and other vehicles passing. This may also help to eliminate the jack-knifing problem if caused by extreme wind side loads on the trailer. Lastly, reduction of the turbulent wake behind the trailer can reduce splash and spray patterns and rough air being experienced by following vehicles. To be presented by GTRI in this paper will be results developed during the early portion of this effort, including a preliminary systems study, CFD prediction of the blown flowfields, and design of the baseline conventional tractor-trailer model and the pneumatic wind-tunnel model.

  1. A pneumatic power harvesting ankle-foot orthosis to prevent foot-drop

    PubMed Central

    Chin, Robin; Hsiao-Wecksler, Elizabeth T; Loth, Eric; Kogler, Géza; Manwaring, Scott D; Tyson, Serena N; Shorter, K Alex; Gilmer, Joel N

    2009-01-01

    Background A self-contained, self-controlled, pneumatic power harvesting ankle-foot orthosis (PhAFO) to manage foot-drop was developed and tested. Foot-drop is due to a disruption of the motor control pathway and may occur in numerous pathologies such as stroke, spinal cord injury, multiple sclerosis, and cerebral palsy. The objectives for the prototype PhAFO are to provide toe clearance during swing, permit free ankle motion during stance, and harvest the needed power with an underfoot bellow pump pressurized during the stance phase of walking. Methods The PhAFO was constructed from a two-part (tibia and foot) carbon composite structure with an articulating ankle joint. Ankle motion control was accomplished through a cam-follower locking mechanism actuated via a pneumatic circuit connected to the bellow pump and embedded in the foam sole. Biomechanical performance of the prototype orthosis was assessed during multiple trials of treadmill walking of an able-bodied control subject (n = 1). Motion capture and pressure measurements were used to investigate the effect of the PhAFO on lower limb joint behavior and the capacity of the bellow pump to repeatedly generate the required pneumatic pressure for toe clearance. Results Toe clearance during swing was successfully achieved during all trials; average clearance 44 ± 5 mm. Free ankle motion was observed during stance and plantarflexion was blocked during swing. In addition, the bellow component repeatedly generated an average of 169 kPa per step of pressure during ten minutes of walking. Conclusion This study demonstrated that fluid power could be harvested with a pneumatic circuit built into an AFO, and used to operate an actuated cam-lock mechanism that controls ankle-foot motion at specific periods of the gait cycle. PMID:19527526

  2. Hydraulic anisotropy characterization of pneumatic-fractured sediments using azimuthal self potential gradient.

    PubMed

    Wishart, DeBonne N; Slater, Lee D; Schnell, Deborah L; Herman, Gregory C

    2009-01-26

    The pneumatic fracturing technique is used to enhance the permeability and porosity of tight unconsolidated soils (e.g. clays), thereby improving the effectiveness of remediation treatments. Azimuthal self potential gradient (ASPG) surveys were performed on a compacted, unconsolidated clay block in order to evaluate their potential to delineate contaminant migration pathways in a mechanically-induced fracture network. Azimuthal resistivity (ARS) measurements were also made for comparative purposes. Following similar procedures to those used in the field, compressed kaolinite sediments were pneumatically fractured and the resulting fracture geometry characterized from strike analysis of visible fractures combined with strike data from optical borehole televiewer (BHTV) imaging. We subsequently injected a simulated treatment (electrolyte/dye) into the fractures. Both ASPG and ARS data exhibit anisotropic geoelectric signatures resulting from the fracturing. Self potentials observed during injection of electrolyte are consistent with electrokinetic theory and previous laboratory results on a fracture block model. Visual (polar plot) analysis and linear regression of cross plots show ASPG lobes are correlated with azimuths of high fracture strike density, evidence that the ASPG anisotropy is a proxy measure of hydraulic anisotropy created by the pneumatic fracturing. However, ARS data are uncorrelated with fracture strike maxima and resistivity anisotropy is probably dominated by enhanced surface conduction along azimuths of weak 'starter paths' formed from pulverization of the clay and increases in interfacial surface area. We find the magnitude of electrokinetic SP scales with the applied N2 gas pressure gradient (DeltaPN2) for any particular hydraulically-active fracture set and that the positive lobe of the ASPG anomaly indicates the flow direction within the fracture network. These findings demonstrate the use of ASPG in characterizing the effectiveness of (1

  3. Hydraulic anisotropy characterization of pneumatic-fractured sediments using azimuthal self potential gradient

    USGS Publications Warehouse

    Wishart, D.N.; Slater, L.D.; Schnell, D.L.; Herman, G.C.

    2009-01-01

    The pneumatic fracturing technique is used to enhance the permeability and porosity of tight unconsolidated soils (e.g. clays), thereby improving the effectiveness of remediation treatments. Azimuthal self potential gradient (ASPG) surveys were performed on a compacted, unconsolidated clay block in order to evaluate their potential to delineate contaminant migration pathways in a mechanically-induced fracture network. Azimuthal resistivity (ARS) measurements were also made for comparative purposes. Following similar procedures to those used in the field, compressed kaolinite sediments were pneumatically fractured and the resulting fracture geometry characterized from strike analysis of visible fractures combined with strike data from optical borehole televiewer (BHTV) imaging. We subsequently injected a simulated treatment (electrolyte/dye) into the fractures. Both ASPG and ARS data exhibit anisotropic geoelectric signatures resulting from the fracturing. Self potentials observed during injection of electrolyte are consistent with electrokinetic theory and previous laboratory results on a fracture block model. Visual (polar plot) analysis and linear regression of cross plots show ASPG lobes are correlated with azimuths of high fracture strike density, evidence that the ASPG anisotropy is a proxy measure of hydraulic anisotropy created by the pneumatic fracturing. However, ARS data are uncorrelated with fracture strike maxima and resistivity anisotropy is probably dominated by enhanced surface conduction along azimuths of weak 'starter paths' formed from pulverization of the clay and increases in interfacial surface area. We find the magnitude of electrokinetic SP scales with the applied N2 gas pressure gradient (??PN2) for any particular hydraulically-active fracture set and that the positive lobe of the ASPG anomaly indicates the flow direction within the fracture network. These findings demonstrate the use of ASPG in characterizing the effectiveness of (1

  4. Effects of pulsed Nd:YAG laser on the surface of rabbit retina

    SciTech Connect

    Fleck, B.W.; Chew, P.T.; Lim, A.S.; Tock, E.P. )

    1991-03-01

    Six albino rabbits were subjected to pulsed Nd:YAG laser irradiation to the retinal surface to determine whether such treatment would lead to proliferative vitreoretinopathy. Choroidal, retinal, and preretinal hemorrhages, noted at the time of treatment, resolved after 7 to 10 days. Histological examination showed no signs of anterior segment damage or proliferative vitreoretinopathy. These preliminary findings suggest that more extensive experimentation is warranted to determine if pulsed Nd:YAG laser may in fact safely be used to separate vitreoretinal adhesions in the treatment of retinal detachment.

  5. Selective ablation of WHHLMI rabbit atherosclerotic plaque by quantum cascade laser in the 5.7 μm wavelength range for less-invasive laser angioplasty

    NASA Astrophysics Data System (ADS)

    Hashimura, Keisuke; Ishii, Katsunori; Akikusa, Naota; Edamura, Tadataka; Yoshida, Harumasa; Awazu, Kunio

    2013-06-01

    We investigated the potential of a compact and high-power quantum cascade laser (QCL) in the 5.7 μm wavelength range for less-invasive laser angioplasty. Atherosclerotic plaques consist mainly of cholesteryl esters. Radiation at a wavelength of 5.75 μm is strongly absorbed in C=O stretching vibration mode of cholesteryl esters. Our previous study achieved to make cutting differences between a normal artery and an atherosclerotic lesions using nanosecond pulsed laser by difference-frequency generation (DFG laser) at the wavelength of 5.75 μm. For applying this technique to clinical treatment, a compact laser device is required. In this study, QCL irradiation effects to a porcine normal aorta were compared with DFG laser. Subsequently, QCL irradiation effects on an atherosclerotic aorta of myocardial infarction-prone Watanabe heritable hyperlipidemic rabbit (WHHLMI rabbit) and a normal rabbit aorta were observed. As a result, the QCL could make cutting differences between the rabbit atherosclerotic and normal aortas. On the other hand, the QCL induced more thermal damage to porcine normal aorta than the DFG laser at the irradiation condition of comparable ablation depths. In conclusion, the possibility of less-invasive and selective treatment of atherosclerotic plaques using the QCL in the 5.7 μm wavelength range was revealed, although improvement of QCL was required to prevent the thermal damage of a normal artery.

  6. USE OF SILICON CARBIDE MONITORS IN ATR IRRADIATION TESTING

    SciTech Connect

    K. L. Davis; B. Chase; T. Unruh; D. Knudson; J. L. Rempe

    2012-07-01

    In April 2007, the Department of Energy (DOE) designated the Advanced Test Reactor (ATR) a National Scientific User Facility (NSUF) to advance US leadership in nuclear science and technology. By attracting new users from universities, laboratories, and industry, the ATR will support basic and applied nuclear research and development and help address the nation's energy security needs. In support of this new program, the Idaho National Laboratory (INL) has developed in-house capabilities to fabricate, test, and qualify new and enhanced temperature sensors for irradiation testing. Although most efforts emphasize sensors capable of providing real-time data, selected tasks have been completed to enhance sensors provided in irradiation locations where instrumentation leads cannot be included, such as drop-in capsule and Hydraulic Shuttle Irradiation System (HSIS) or 'rabbit' locations. For example, silicon carbide (SiC) monitors are now available to detect peak irradiation temperatures between 200°C and 800°C. Using a resistance measurement approach, specialized equipment installed at INL's High Temperature Test Laboratory (HTTL) and specialized procedures were developed to ensure that accurate peak irradiation temperature measurements are inferred from SiC monitors irradiated at the ATR. Comparison examinations were completed by INL to demonstrate this capability, and several programs currently rely on SiC monitors for peak temperature detection. This paper discusses the use of SiC monitors at the ATR, the process used to evaluate them at the HTTL, and presents representative measurements taken using SiC monitors.

  7. Experimental studies on intelligent fault detection and diagnosis using sensor networks on mechanical pneumatic systems

    NASA Astrophysics Data System (ADS)

    Zhang, Kunbo; Kao, Imin; Kambli, Sachin; Boehm, Christian

    2008-03-01

    Fault is a undesirable factor in any mechanical/pneumatic system. It affects the efficiency of system operation and reduces economic benefit in industry. The early detection and diagnosis of faults in a mechanical system becomes important for preventing failure of equipment and loss of productivity and profits. In this paper, we present our ongoing research results on intelligent fault detections and diagnosis (FDD) on mechanical/ pneumatic systems. Using data from sensors and sensor network in an integrated industrial system, our proposed FDD methodology provides the analysis of necessary sensory information (for example, flow rates and pressure, as well as other digital sensor data) for the detection and diagnosis of system fault. In this experimental study, the leakage of pneumatic cylinder was the "fault." It was shown that the FDD analysis was able to make diagnosis of leakage both in location and size of the fault. In addition, the systematic fault and localized faults can be detected separately. The proposed wavelet method gives rise to the fingerprint analysis to recognize the patterns of the flow rate and pressure data - a very useful tool in intelligent fault detection and diagnosis.

  8. Continued Development and Application of Circulation Control Pneumatic Technology to Advanced Transport Aircraft

    NASA Technical Reports Server (NTRS)

    Englar, Robert J.

    1998-01-01

    Personnel of the Georgia Tech Research Institute (GTRI) Aerospace and Transportation Lab have completed a four-year grant program to develop and evaluate the pneumatic aerodynamic technology known as Circulation Control (CC) or Circulation Control Wing (CCW) for advanced transport aircraft. This pneumatic technology, which employs low-level blowing from tangential slots over round or near-round trailing edges of airfoils, greatly augments the circulation around a lifting or control surface and thus enhances the aerodynamic forces and moments generated by that surface. Two-dimensional force augmentations as high as 80 times the input blowing momentum coefficient have been recorded experimentally for these blown devices, thus providing returns of 8000% on the jet momentum expended. A further benefit is the absence of moving parts such as mechanical flaps, slats, spoilers, ailerons, elevators and rudders from these pneumatic surfaces, or the use of only very small, simple, blown aerodynamic surfaces on synergistic designs which integrate the lift, drag and control surfaces. The application of these devices to advanced aircraft can offer significant benefits in their performance, efficiency, simplicity, reliability, economic cost of operation, noise reduction, and safety of flight. To further develop and evaluate this potential, this research effort was conducted by GTRI under grant for the NASA Langley Research Center, Applied Aerodynamics Division, Subsonic Aerodynamics Branch, between June 14, 1993 and May 31, 1997.

  9. Static and dynamic stability of pneumatic vibration isolators and systems of isolators

    NASA Astrophysics Data System (ADS)

    Ryaboy, Vyacheslav M.

    2014-01-01

    Pneumatic vibration isolation is the most widespread effective method for creating vibration-free environments that are vital for precise experiments and manufacturing operations in optoelectronics, life sciences, microelectronics, nanotechnology and other areas. The modeling and design principles of a dual-chamber pneumatic vibration isolator, basically established a few decades ago, continue to attract attention of researchers. On the other hand, behavior of systems of such isolators was never explained in the literature in sufficient detail. This paper covers a range of questions essential for understanding the mechanics of pneumatic isolation systems from both design and application perspectives. The theory and a model of a single standalone isolator are presented in concise form necessary for subsequent analysis. Then the dynamics of a system of isolators supporting a payload is considered with main attention directed to two aspects of their behavior: first, the static stability of payloads with high positions of the center of gravity; second, dynamic stability of the feedback system formed by mechanical leveling valves. The direct method of calculating the maximum stable position of the center of gravity is presented and illustrated by three-dimensional stability domains; analytic formulas are given that delineate these domains. A numerical method for feedback stability analysis of self-leveling valve systems is given, and the results are compared with the analytical estimates for a single isolator. The relation between the static and dynamic phenomena is discussed.

  10. Ultrasonic Friction Reduction in Elastomer - Metal Contacts and Application to Pneumatic Actuators

    NASA Astrophysics Data System (ADS)

    Pham, The Minh; Twiefel, Jens

    Ultrasonic friction reduction is well known in metal-metal contacts. Due to the vibration, the stick phase in the contact phase vanishes and only sliding occurs. As long as the macroscopic relative velocity of the contact partners is much lower than vibration velocity, the necessary force to move the parts tends to (nearly) zero. If the effect also exists in material combinations with a significant difference in stiffness and damping characteristic has not been investigated in the past. This contribution shows the effect for various material combinations, which are typical for sealings in pneumatic actuators. Further, a novel integrated transducer design for a pneumatic actuator is presented. In this design the transducer also acts as moving part within the pneumatic actuator. The design challenges are the two contact areas on the moving part, where the friction reduction and consequently high vibration amplitudes are needed. The first area is fixed on the transducer geometry, the other is moving along the piston. This novel design has been implemented in the laboratory; detailed experimental results are presented in this contribution.

  11. Outcomes in achalasia from a surgical unit where pneumatic dilatation is first-line therapy.

    PubMed

    Howard, J M; Mongan, A-M; Manning, B J; Byrne, P; Lawler, P; Ravi, N; Reynolds, J V

    2010-08-01

    The management of achalasia remains controversial, with little consensus on the optimal patient treatment pathway. In our own esophageal unit, we offer pneumatic dilatation as the initial therapy in most patients as first-line therapy. In this study, we aimed to examine the safety and efficacy of our own approach to the management of patients with a diagnosis of achalasia, examining symptomatic outcomes, patient satisfaction, and need for further intervention, as well as examining patient factors associated with treatment failure. Sixty-seven consecutive patients underwent pneumatic dilatation as first-line therapy (53% male, mean age 46 years). All attended regular outpatient follow-up (mean 37, range 3-132 months). Twenty-five percent of patients required a second intervention because of symptom recurrence, at a median period of 4.5 months. Symptomatic outcomes were excellent or good in 80%. Significant predictors of treatment failure and poor symptom score included a younger age at the time of diagnosis and increased esophageal diameter on barium swallow. This study suggests that pneumatic dilatation is a safe and effective approach as first-line therapy in patients with newly diagnosed achalasia.

  12. Direct adaptive fuzzy control of a translating piezoelectric flexible manipulator driven by a pneumatic rodless cylinder

    NASA Astrophysics Data System (ADS)

    Qiu, Zhi-cheng; Wang, Bin; Zhang, Xian-min; Han, Jian-da

    2013-04-01

    This study presents a novel translating piezoelectric flexible manipulator driven by a rodless cylinder. Simultaneous positioning control and vibration suppression of the flexible manipulator is accomplished by using a hybrid driving scheme composed of the pneumatic cylinder and a piezoelectric actuator. Pulse code modulation (PCM) method is utilized for the cylinder. First, the system dynamics model is derived, and its standard multiple input multiple output (MIMO) state-space representation is provided. Second, a composite proportional derivative (PD) control algorithms and a direct adaptive fuzzy control method are designed for the MIMO system. Also, a time delay compensation algorithm, bandstop and low-pass filters are utilized, under consideration of the control hysteresis and the caused high-frequency modal vibration due to the long stroke of the cylinder, gas compression and nonlinear factors of the pneumatic system. The convergence of the closed loop system is analyzed. Finally, experimental apparatus is constructed and experiments are conducted. The effectiveness of the designed controllers and the hybrid driving scheme is verified through simulation and experimental comparison studies. The numerical simulation and experimental results demonstrate that the proposed system scheme of employing the pneumatic drive and piezoelectric actuator can suppress the vibration and achieve the desired positioning location simultaneously. Furthermore, the adopted adaptive fuzzy control algorithms can significantly enhance the control performance.

  13. Systematic design of a magneto-rheological fluid embedded pneumatic vibration isolator subject to practical constraints

    NASA Astrophysics Data System (ADS)

    Zhu, Xiaocong; Jing, Xingjian; Cheng, Li

    2012-03-01

    A systematic design of a magneto-rheological fluid embedded pneumatic vibration isolator (MrEPI) considering practical constraints and optimal performance is proposed. The design procedure basically consists of three steps, i.e. system level design, component level design and practical realization. The system level design involves synthesizing appropriate non-dimensional system parameters of pneumatic spring and MR damper elements based on parameter sensitivity analysis considering requirements for compact and efficient hardware utilization. The component level design involves optimal design of the MR valve by minimizing an objective function in terms of non-dimensional geometric, material and excitation parameters, and guaranteeing required performance in the worst cases. Then practical realization involves determining actual plant parameters from the non-dimensional analysis in system and component level designs with the considerations of practical requirements/constraints. To verify the effectiveness of this optimization procedure, the semi-active vibration control performance of the optimized MrEPI subject to harmonic disturbances is evaluated, which shows good isolation performance in all tested cases. This study actually provides a systematic method for the optimal analysis and design of all those nonlinear vibration isolators consisting of pneumatic spring and MR damper elements. This is achieved firstly by developing effective sensitivity analysis of dominant design parameters upon the adjustable stiffness and damping capacity irrespective of bulky or small system mass configuration and subsequently via a systematic realization design with the consideration of practical constraints in applications.

  14. Manually operatable on-chip bistable pneumatic microstructures for microfluidic manipulations.

    PubMed

    Chen, Arnold; Pan, Tingrui

    2014-09-07

    Bistable microvalves are of particular interest because of their distinct nature of requiring energy consumption only during the transition between the open and closed states. This characteristic can be highly advantageous in reducing the number of external inputs and the complexity of control circuitries since microfluidic devices as contemporary lab-on-a-chip platforms are transferring from research settings to low-resource environments with high integrability and a small form factor. In this paper, we first present manually operatable, on-chip bistable pneumatic microstructures (BPMs) for microfluidic manipulation. The structural design and operation of the BPM devices can be readily integrated into any pneumatically powered microfluidic network consisting of pneumatic and fluidic channels. It is mainly composed of a vacuum activation chamber (VAC) and a pressure release chamber (PRC), of which users have direct control through finger pressing to switch either to the bistable vacuum state (VS) or the atmospheric state (AS). We have integrated multiple BPM devices into a 4-to-1 microfluidic multiplexor to demonstrate on-chip digital flow switching from different sources. Furthermore, we have shown its clinical relevance in a point-of-care diagnostic chip that processes blood samples to identify the distinct blood types (A/B/O) on-chip.

  15. Morphing nacelle inlet lip with pneumatic actuators and a flexible nano composite sandwich panel

    NASA Astrophysics Data System (ADS)

    Gulsine Ozdemir, Nazli; Scarpa, Fabrizio; Craciun, Monica; Remillat, Chrystel; Lira, Cristian; Jagessur, Yogesh; Da Rocha-Schmidt, Luiz

    2015-12-01

    We present a hybrid pneumatic/flexible sandwich structure with thermoplastic (TP) nanocomposite skins to enable the morphing of a nacelle inlet lip. The design consists of pneumatic inflatables as actuators and a flexible sandwich panel that morphs under variable pressure combinations to adapt different flight conditions and save fuel. The sandwich panel forms the outer layer of the nacelle inlet lip. It is lightweight, compliant and impact resistant with no discontinuities, and consists of graphene-doped thermoplastic polyurethane (G/TPU) skins that are supported by an aluminium Flex-core honeycomb in the middle, with near zero in-plane Poisson’s ratio behaviour. A test rig for a reduced-scale demonstrator was designed and built to test the prototype of morphing nacelle with custom-made pneumatic actuators. The output force and the deflections of the experimental demonstrator are verified with the internal pressures of the actuators varying from 0 to 0.41 MPa. The results show the feasibility and promise of the hybrid inflatable/nanocomposite sandwich panel for morphing nacelle airframes.

  16. Controllable organization and high throughput production of recoverable 3D tumors using pneumatic microfluidics.

    PubMed

    Liu, Wenming; Wang, Jian-Chun; Wang, Jinyi

    2015-02-21

    Three-dimensional tumor culture methods offer a high degree of biological and clinical relevance to in vitro models as well as cancer therapy. However, a straightforward, dynamic, and high-throughput method for micro-manipulation of 3D tumors is not yet well established. In this study, we present a novel and simple strategy for producing biomimetic 3D tumors in a controllable, high throughput manner based on an integrated microfluidic system with well-established pneumatic microstructures. Serial manipulations, including one-step cell localization, array-like self-assembly, and real-time analysis of 3D tumors, are accomplished smoothly in the microfluidic device. The recovery of tumor products from the chip is performed by dynamic off-switch of the pneumatic microstructures. In addition, this microfluidic platform is demonstrated to be capable of producing multiple types of 3D tumors and performing the evaluation of tumor targeting by nanomedicine. The pneumatic microfluidic-based 3D tumor production shows potential for research on tumor biology, tissue engineering, and drug delivery.

  17. Evacuation of coal from hoppers/silos with low pressure pneumatic blasting systems

    NASA Technical Reports Server (NTRS)

    Fischer, J. S.

    1977-01-01

    The need for an efficient, economical, effective and quiet device for moving coal and other difficult bulk solids was recognized. Thus came the advent of the low pressure pneumatic blasting system - a very efficient means of using a small amount of plant air (up to 125 PSI) to eliminate the most troublesome material hang-ups in storage containers. This simple device has one moving part and uses approximately 3% of the air consumed by a pneumatic vibrator on the same job. The principle of operation is very simple: air stored in the unit's reservoir is expelled directly into the material via a patented quick release valve. The number, size, and placement of the blaster units on the storage vessel is determined by a series of tests to ascertain flowability of the problem material. These tests in conjunction with the hopper or silo configuration determine specification of a low pressure pneumatic blasting system. This concept has often proven effective in solving flow problems when all other means have failed.

  18. Dynamics of a pneumatic artificial muscle actuation system driving a trailing edge flap

    NASA Astrophysics Data System (ADS)

    Woods, Benjamin K. S.; Kothera, Curt S.; Wang, Gang; Wereley, Norman M.

    2014-09-01

    This study presents a time domain dynamic model of an antagonistic pneumatic artificial muscle (PAM) driven trailing edge flap (TEF) system for next generation active helicopter rotors. Active rotor concepts are currently being widely researched in the rotorcraft community as a means to provide a significant leap forward in performance through primary aircraft control, vibration mitigation and noise reduction. Recent work has shown PAMs to be a promising candidate for active rotor actuation due to their combination of high force, large stroke, light weight, and suitable bandwidth. When arranged into biologically inspired agonist/antagonist muscle pairs they can produce bidirectional torques for effectively driving a TEF. However, there are no analytical dynamic models in the literature that can accurately capture the behavior of such systems across the broad range of frequencies required for this demanding application. This work combines mechanical, pneumatic, and aerodynamic component models into a global flap system model developed for the Bell 407 rotor system. This model can accurately predict pressure, force, and flap angle response to pneumatic control valve inputs over a range of operating frequencies from 7 to 35 Hz (1/rev to 5/rev for the Bell 407) and operating pressures from 30 to 90 psi.

  19. Pneumatic compression devices for in-home management of lymphedema: two case reports

    PubMed Central

    2009-01-01

    The two patients in this case series had experienced long-term difficulty controlling lymphedema at home. Both patients had used numerous home therapies, including older-generation intermittent pneumatic compression devices, without success. The Flexitouch® system, an advanced pneumatic device, was prescribed to assist them with in-home efforts by providing therapy to their affected limbs in addition to the lower trunk area for the patient with lymphedema of the lower extremity; and the trunk, chest wall, and shoulder areas for the patient with lymphedema of the upper extremity. Both patients achieved successful home maintenance of lymphedema, as judged by limb volume, clinical observations, and subjective patient impressions, after incorporating the Flexitouch® system. Neither patient experienced the deleterious effects (worsening genital edema; fibrotic cuff development) that they had experienced with the older-generation intermittent pneumatic compression devices they had previously used. Incorporating the Flexitouch® system as part of maintenance may improve success for lymphedema patients who have previously struggled with in-home management. PMID:20184680

  20. Extreme Mechanics in Soft Pneumatic Robots and Soft Microfluidic Electronics and Sensors

    NASA Astrophysics Data System (ADS)

    Majidi, Carmel

    2012-02-01

    In the near future, machines and robots will be completely soft, stretchable, impact resistance, and capable of adapting their shape and functionality to changes in mission and environment. Similar to biological tissue and soft-body organisms, these next-generation technologies will contain no rigid parts and instead be composed entirely of soft elastomers, gels, fluids, and other non-rigid matter. Using a combination of rapid prototyping tools, microfabrication methods, and emerging techniques in so-called ``soft lithography,'' scientists and engineers are currently introducing exciting new families of soft pneumatic robots, soft microfluidic sensors, and hyperelastic electronics that can be stretched to as much as 10x their natural length. Progress has been guided by an interdisciplinary collection of insights from chemistry, life sciences, robotics, microelectronics, and solid mechanics. In virtually every technology and application domain, mechanics and elasticity have a central role in governing functionality and design. Moreover, in contrast to conventional machines and electronics, soft pneumatic systems and microfluidics typically operate in the finite deformation regime, with materials stretching to several times their natural length. In this talk, I will review emerging paradigms in soft pneumatic robotics and soft microfluidic electronics and highlight modeling and design challenges that arise from the extreme mechanics of inflation, locomotion, sensor operation, and human interaction. I will also discuss perceived challenges and opportunities in a broad range of potential application, from medicine to wearable computing.

  1. Development of a compact portable driver for a pneumatic ventricular assist device.

    PubMed

    Nishinaka, Tomohiro; Taenaka, Yoshiyuki; Tatsumi, Eisuke; Ohnishi, Hiroyuki; Homma, Akihiko; Shioya, Kyoko; Mizuno, Toshihide; Tsukiya, Tomonori; Mushika, Sadahiko; Hashiguchi, Yasuhiro; Suzuki, Akira; Kitamura, Soichiro

    2007-01-01

    The Toyobo-National Cardiovascular Center pneumatic ventricular assist device (Toyobo-NCVC VAD) is widely used in Japan; however, the current pneumatic drivers have some drawbacks, including their large size, heavy weight, and high power consumption. These issues cause difficulty with mobility and contribute to an unsatisfactory quality of life for patients. Because it is urgently necessary to improve patients' safety and quality of life, we have developed a compact, low-noise, portable VAD driver by utilizing an electrohydraulic actuator consisting of a brushless DC motor and a regenerative pump. This unit can be actuated for as long as 2 h with two rechargeable lightweight batteries as well as with external AC power. It is compact in size (33 x 25 x 43 cm) and light in weight (13 kg), and the unit is carried on a mobile wheeled cart. In vitro testing with a Toyobo-NCVC VAD demonstrated a sufficient pumping capacity of up to 8 l/min. We conclude that this newly-developed compact portable driver can provide a better quality of life and improved safety for patients using protracted pneumatic VAD support.

  2. Development of a closed air loop electropneumatic actuator for driving a pneumatic blood pump.

    PubMed

    Jeong, Gi Seok; Hwang, Chang Mo; Nam, Kyoung Won; Ahn, Chi Bum; Kim, Ho Chul; Lee, Jung Joo; Choi, Jaesoon; Son, Ho Sung; Fang, Yong Hu; Son, Kuk Hui; Lim, Choon Hak; Sun, Kyung

    2009-08-01

    In this study, we developed a small pneumatic actuator that can be used as an extracorporeal biventricular assist device. It incorporated a bellows-transforming mechanism to generate blood-pumping pressure. The cylindrical unit is 88 +/- 0.1 mm high, has a diameter of 150 +/- 0.1 mm, and weighs 2.4 +/- 0.01 kg. In vitro, maximal outflow at the highest pumping rate (PR) exceeded 8 L/min when two 55 mL blood sacs were used under an afterload pressure of 100 mm Hg. At a pumping rate of 100 beats per minute (bpm), maximal hydraulic efficiency was 9.34% when the unit supported a single ventricle and 13.8% when it supported both ventricles. Moreover, pneumatic efficiencies of the actuator were 17.3% and 33.1% for LVAD and BVAD applications, respectively. The energy equivalent pressure was 62.78 approximately 208.10 mm Hg at a PR of 60 approximately 100 bpm, and the maximal value of dP/dt during systole was 1269 mm Hg/s at a PR of 60 bpm and 979 mm Hg/s at a PR of 100 bpm. When the unit was applied to 15 calves, it stably pumped 3 approximately 4 L/min of blood at 60 bpm, and no mechanical malfunction was experienced over 125 days of operation. We conclude that the presently developed pneumatic actuator can be utilized as an extracorporeal biventricular assist device.

  3. Manually Operatable On-Chip Bistable Pneumatic Microstructures for Microfluidic Manipulations

    PubMed Central

    Chen, A.; Pan, T.

    2014-01-01

    Bistable microvalves are of particular interest because of their distinct nature requiring energy consumption only during the transition between the open and closed states. This characteristic can be highly advantageous in reducing the number of external inputs and the complexity of control circuitries for microfluidic devices as contemporary lab-on-a-chip platforms are transferring from research settings to low-resource environments with high integratability and small form factor. In this paper, we first present manually operatable, on-chip bistable pneumatic microstructures (BPM) for microfluidic manipulation. The structural design and operation of the BPM devices can be readily integrated into any pneumatically powered microfluidic network consisting of pneumatic and fluidic channels. It is mainly comprised of a vacuum activation chamber (VAC) and a pressure release chamber (PRC), which users have direct control through finger pressing to switch between bistable vacuum state (VS) or atmospheric state (AS). We have integrated multiple BPM devices into a 4-to-1 microfluidic multiplexor to demonstrate on-chip digital flow switching from different sources. Furthermore, we have shown its clinical relevance in a point-of-care diagnostic chip that process blood samples to identify the distinct blood types (A/B/O) on chip. PMID:25007840

  4. The maxillary sinus in three genera of new world monkeys: factors that constrain secondary pneumatization.

    PubMed

    Smith, Timothy D; Rossie, James B; Cooper, Gregory M; Carmody, Kelly A; Schmieg, Robin M; Bonar, Christopher J; Mooney, Mark P; Siegel, Michael I

    2010-01-01

    The air filled cavities of paranasal sinuses are thought by some to appear opportunistically in spatial "gaps" within the craniofacial complex. Anthropoid primates provide excellent natural experiments for testing this model, since not all species possess a full complement of paranasal sinuses. In this study, two genera of monkeys (Saguinus and Cebuella) which form maxillary sinuses (MS) as adults were compared to squirrel monkeys (Saimiri spp.), in which a MS does not form. Using microCT and histomorphometric methods, the spatial position of paranasal spaces was assessed and size of the adjacent dental sacs was measured. In Saguinus, secondary pneumatization is underway perinatally, and the sinus extends alongside deciduous premolars (dp). The MS overlaps all permanent molars in the adult. In Saimiri, the homologous space (maxillary recess) extends no farther posterior than the first deciduous premolar at birth and extends no farther than the last premolar in the adult. Differences in dental size and position may account for this finding. For example, Saimiri has significantly larger relative dp volumes, and enlarged orbits, which encroach on the internasal space to a greater degree when compared to Saguinus. These factors limit space for posterior expansion of the maxillary recess. These findings support the hypothesis that secondary pneumatization is a novel, opportunistic growth mechanism that removes "unneeded" bone. Moreover, paranasal spaces occur in association with semiautonomous skeletal elements that border more than one functional matrix, and the spatial dynamics of these units can act as a constraint on pneumatic expansion of paranasal spaces.

  5. Welding irradiated stainless steel

    SciTech Connect

    Kanne, W.R. Jr.; Chandler, G.T.; Nelson, D.Z.; Franco-Ferreira, E.A.

    1993-12-31

    Conventional welding processes produced severe underbead cracking in irradiated stainless steel containing 1 to 33 appm helium from n,a reactions. A shallow penetration overlay technique was successfully demonstrated for welding irradiated stainless steel. The technique was applied to irradiated 304 stainless steel that contained 10 appm helium. Surface cracking, present in conventional welds made on the same steel at the same and lower helium concentrations, was eliminated. Underbead cracking was minimal compared to conventional welding methods. However, cracking in the irradiated material was greater than in tritium charged and aged material at the same helium concentrations. The overlay technique provides a potential method for repair or modification of irradiated reactor materials.

  6. Experimental Toxoplasmic Lymphadenopathy in Rabbits

    PubMed Central

    Henry, L.; Beverley, J. K. A.; Shortland, J. R.; Coup, A. J.

    1973-01-01

    The pathogenesis of toxoplasmic lymphadenopathy was studied in rabbits. Sixteen were infected with a high virulence strain of Toxoplasma gondii and 32 with one of low virulence. The former group were killed and examined at intervals up to 9 days and the latter up to 129 days. The high virulence strain quickly caused paracortical hyperplasia but only moderate follicular reaction. Later, lymphoid depletion occurred. The low virulence strain caused follicular reaction so that at 16 days germinal centres had developed with evidence of cellular phagocytosis. Histiocytes were present and plasma cells were found in the medullary cords. These appearances were seen up to 51 days. At 86 days the follicular reaction was no longer present but had returned at 129 days. These results were supplemented by serological, parasitological, immunofluorescence and electron microscopic data. The histological changes seen in the low virulence infections up to 51 days are unlike those caused by the high virulence strain but closely parallel those found in acquired infections in man, which are usually caused by strains of the low virulence type. These findings may help to elucidate the nature of the complex immune responses and the pathogenesis of toxoplasma infections. ImagesFigs. 14-15Figs. 16, 18 and 19Figs. 12-13Figs. 7-11Figs. 1-6 PMID:4577945

  7. Antiradiation vaccine: Technology and development of prophylaxis, prevention and treatment of biological consequences from Heavy Ion irradiation.

    NASA Astrophysics Data System (ADS)

    Popov, Dmitri; Maliev, Vecheslav

    Introduction: An anti-radiation vaccine could be an important part of a countermeasures reg-imen for effective radioprotection, immunoprophylaxis and immunotherapy of the acute radi-ation syndromes (ARS) after gamma-irradiation, neutron irradiation or heavy ion irradiation. Reliable protection of non-neoplastic regions of patients with different forms of cancer which undergo to heavy ion therapy ( e.g. Hadron-therapy) can significantly extend the efficiency of the therapeutic course. The protection of cosmonauts astronauts from the heavy ion ra-diation component of space radiation with specific immunoprophylaxis by the anti-radiation vaccine may be an important part of medical management for long term space missions. Meth-ods and experiments: 1. The Antiradiation Vaccine preparation -standard (mixture of toxoid form of Radiation Toxins -SRD-group) which include Cerebrovascular RT Neurotoxin, Car-diovascular RT Neurotoxin, Gastrointestinal RT Neurotoxin, Hematopoietic RT Hematotoxin. Radiation Toxins Specific Radiation Determinant Group were isolated from a central lymph of gamma-irradiated animals with Cerebrovascular, Cardiovascular, Gastrointestiinal, Hematopoi-etic forms of ARS. Devices for γ-radiation are "Panorama", "Puma". 2. Heavy ion exposure was accomplished at Department of Scientific Research Institute of Nuclear Physics, Dubna, Russia. The heavy ions irradiation was generated in heavy ion (Fe56) accelerator -UTI. Heavy Ion linear transfer energy -2000-2600 KeV mkm, 600 MeV U. Absorbed Dose -3820 Rad. 3. Experimental Design: Rabbits from all groups were irradiated by heavy ion accelerator. Group A -control -10 rabbits; Group B -placebo -5 rabbits; Group C -radioprotectant Cystamine (50 mg kg)-5 rabbits, 15 minutes before irradiation -5 rabbits; Group D -radioprotectant Gammafos (Amifostine -400mg kg ), -5 rabbits; Group E -Antiradiation Vaccine: subcuta-neus administration or IM -2 ml of active substance, 14 days before irradiation -5 rabbits. 4

  8. In vitro CD4+ lymphocyte transformation and infection in a rabbit model with a molecular clone of human T-cell lymphotrophic virus type 1.

    PubMed Central

    Collins, N D; Newbound, G C; Ratner, L; Lairmore, M D

    1996-01-01

    We transfected human and rabbit peripheral blood mononuclear cells (PBMC) with the ACH molecular clone of human T-cell lymphotropic virus type 1 (HTLV-1) to study its in vitro and in vivo properties. PBMC transfected with ACH were shown to transfer infection to naive PBMC. ACH transformed rabbit PBMC, as indicated by interleukin-2-independent proliferation of a transfectant culture. This transformant culture was shown by flow cytometric analysis to be a CD4+ CD25+ T-lymphocyte population containing, as determined by Southern blot analysis, at least three integrated HTLV-1 proviral copies. HTLV-1 infection was produced in rabbits inoculated with ACH-transfected, irradiated PBMC. Inoculated rabbits seroconverted to positivity for antibodies against HTLV-1 and had steady or rising HTLV-1 enzyme-linked immunosorbent assay antibody titers. Western blot (immunoblot) analysis revealed sustained seroconversion of rabbits to positivity for antibodies against all major viral antigenic determinants. Infection of rabbits was further demonstrated by antigen capture assay of p24 in PBMC and lymph node cultures and PCR amplification of proviral sequences from PBMC. These data suggest that ACH, like wild-type HTLV-1, infects and transforms primary CD4+ T lymphocytes and is infectious in vivo. This clone will facilitate investigations into the role of viral genes on biological properties of HTLV-1 in vitro and in vivo. PMID:8794375

  9. An in-vitro study of irradiated vitreo-retinal membranes.

    PubMed

    Chakravarthy, U; McCormick, D; Maguire, C J; Archer, D B

    1987-01-01

    Standard perforating injuries were created in the right eye of 30 rabbits. Twenty of these had the site of injury irradiated using the radioactive ophthalmic 60Cobalt applicator. Vitreo-retinal membranes obtained from non-irradiated and irradiated eyes were propagated in vitro. The morphology and viability of the cells that grew as a monolayer was studied using phase, light and electron microscopy. The proportions of the different cell types that constituted the monolayer was determined using immunofluorescent staining techniques. Non-irradiated membranes elaborated an abundant outgrowth of healthy cells that were predominantly fibroblasts. Irradiated membranes developed a sparse outgrowth of cells with vacuolated cytoplasm and pyknotic nuclei indicating cell destruction. The majority of the surviving cells were glial, with fibroblasts and retinal pigment epithelial cells forming the remainder.

  10. Damage and repair of irradiated mammalian brain

    SciTech Connect

    Frankel, K.; Lo, E.; Phillips, M.; Fabrikant, J.; Brennan, K.; Valk, P.; Poljak, A.; Delapaz, R.; Woodruff, K.; Stanford Univ., CA . Medical Center; Brookside Hospital, San Pablo, CA )

    1989-07-01

    We have demonstrated that focal charged particle irradiation of the rabbit brain can create well-defined lesions which are observable by nuclear magnetic resonance imaging (NMR) and positron emission tomography (PET) imaging techniques. These are similar, in terms of location and characteristic NMR and PET features, to those that occur in the brain of about 10% of clinical research human subjects, who have been treated for intracranial vascular malformations with stereotactic radiosurgery. These lesions have been described radiologically as vasogenic edema of the deep white matter,'' and the injury is of variable intensity and temporal duration, can recede or progress to serious neurologic sequelae, and persist for a considerable period of time, frequently 18 mon to 3 yr. 8 refs., 6 figs.

  11. The Effect of Neutron Irradiation on the Fracture Toughness of Graphite

    SciTech Connect

    Burchell, Timothy D; Strizak, Joe P

    2012-01-01

    As part of our irradiated graphite recycle program a small quantity of PCEA grade graphite was irradiated in the High Flux Isotope Reactor (HFIR) at ORNL. The graphite will provide the raw material for future recycle experiments. The geometry of the irradiated graphite allowed us to study the effects of neutron irradiation on the Critical Stress Intensity Factor, KIc, of graphite. The specimens where irradiated in two groups of 6 at an irradiation temperature of 900 C in rabbit capsules to doses of 6.6 and 10.2 DPA, respectively. Following a full suite of pre-and post-irradiation examination, which included dimensions, mass, electrical resistivity, elastic constants, and thermal expansion (to 800 C) the samples were notched and tested to determine their KIc using the newly approved ATSM test method for SENB fracture toughness of graphite. Here we report the irradiation induced changes in the dimensions, elastic constants, resistivity, and coefficient of thermal expansion of PCEA graphite. Moreover, irradiation induced changes in the Critical Stress Intensity Factor, KIc, or fracture toughness, are reported and discussed. Very little work on the effect of neutron irradiation on the fracture toughness of graphite has previously be performed or reported.

  12. Evaluation of electrosurgical meniscectomy in rabbits.

    PubMed

    Schosheim, P M; Caspari, R B

    1986-01-01

    Recently, electrosurgical cutting instruments utilizing radiofrequency energy have been designed as arthroscopic devices for cutting meniscal tissue. This study attempted to determine the in vivo gross and microscopic effects of radiofrequency energy on meniscal tissue in rabbits. Twelve adult New Zealand white rabbits (48 menisci) underwent bilateral knee arthrotomies. Ten rabbits (40 menisci) underwent partial meniscectomies in which one half of each meniscus in the longitudinal plane was removed with the electrosurgical generator. Two control rabbits underwent arthrotomy without resection of meniscal tissue. At specific time intervals, the rabbits were killed, and the menisci were removed. The gross specimens were photographed, and microscopic sections of each meniscus were fixed and stained. Specimens were evaluated to determine the cellular and vascular response to the electrosurgical cut edge of each meniscus. The microscopic specimens revealed that the radiofrequency cutting instruments produced a small degree of direct thermal damage to the cut meniscus. A tissue response producing a hypercellular dense collagen matrix was present for approximately 3 months. The spontaneous repair of tissue was complete by 6 months, and the histologic 6-month specimens could not be distinguished from the 6-month control specimens except with respect to the overall width of the specimens.

  13. Hypercholesterolemia Impaired Sperm Functionality in Rabbits

    PubMed Central

    Monclus, Maria A.; Cabrillana, Maria E.; Clementi, Marisa A.; Espínola, Leandro S.; Cid Barría, Jose L.; Vincenti, Amanda E.; Santi, Analia G.; Fornés, Miguel W.

    2010-01-01

    Hypercholesterolemia represents a high risk factor for frequent diseases and it has also been associated with poor semen quality that may lead to male infertility. The aim of this study was to analyze semen and sperm function in diet-induced hypercholesterolemic rabbits. Twelve adult White New Zealand male rabbits were fed ad libitum a control diet or a diet supplemented with 0.05% cholesterol. Rabbits under cholesterol-enriched diet significantly increased total cholesterol level in the serum. Semen examination revealed a significant reduction in semen volume and sperm motility in hypercholesterolemic rabbits (HCR). Sperm cell morphology was seriously affected, displaying primarily a “folded head”-head fold along the major axe-, and the presence of cytoplasmic droplet on sperm flagellum. Cholesterol was particularly increased in acrosomal region when detected by filipin probe. The rise in cholesterol concentration in sperm cells was determined quantitatively by Gas chromatographic-mass spectrometric analyses. We also found a reduction of protein tyrosine phosphorylation in sperm incubated under capacitating conditions from HCR. Interestingly, the addition of Protein Kinase A pathway activators -dibutyryl-cyclic AMP and iso-butylmethylxanthine- to the medium restored sperm capacitation. Finally, it was also reported a significant decrease in the percentage of reacted sperm in the presence of progesterone. In conclusion, our data showed that diet-induced hypercholesterolemia adversely affects semen quality and sperm motility, capacitation and acrosomal reaction in rabbits; probably due to an increase in cellular cholesterol content that alters membrane related events. PMID:20976152

  14. Experimental rabbit models of Chlamydia pneumoniae infection.

    PubMed Central

    Moazed, T. C.; Kuo, C.; Patton, D. L.; Grayston, J. T.; Campbell, L. A.

    1996-01-01

    Chlamydia pneumoniae (TWAR), a common cause of acute respiratory disease in humans, has recently been associated with coronary and aortic atherosclerosis. In this study, we evaluated rabbit models of chlamydial infection to investigate the pathogenesis of C. pneumoniae infection. New Zealand White rabbits were inoculated intranasally and intratracheally with C. pneumoniae, strain AR-39, and primary and repeated infection were assessed. After a single inoculation, lung pathology was characterized by a moderate self-resolving interstitial pneumonia with bronchiolitis of 21 days in duration. Chlamydial DNA was detected by polymerase chain reaction (PCR) intermittently in the upper respiratory tract and lung tissue through day 21 postinoculation, spleen tissue at day 14, and peripheral blood mononuclear cells at days 3 and 21. After repeated inoculations, chlamydial DNA was detected by PCR in the upper respiratory tract and lung tissue through day 42. Lung lesions consisted of multifocal interstitial mononuclear cell aggregates that persisted up to day 42. Watanabe heritable hyperlipidemic rabbits were less susceptible to C. pneumoniae infection. After multiple inoculations of Watanabe rabbits, C. pneumoniae was detected by PCR and/or immunocytochemistry until day 21. In conclusion, C. pneumoniae induced a moderate respiratory infection in these rabbit models. Images Figure 1 Figure 2 Figure 3 PMID:8579129

  15. 9 CFR 354.124 - Quarantine of diseased rabbits.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... shall be dealt with in one of the following ways: (a) If it is determined by a veterinary inspector that... veterinary inspector that further handling of the rabbits will not create a health hazard, such rabbits...

  16. SPF rabbits infected with rabbit hepatitis E virus isolate experimentally showing the chronicity of hepatitis.

    PubMed

    Han, Jian; Lei, Yaxin; Liu, Lin; Liu, Peng; Xia, Junke; Zhang, Yulin; Zeng, Hang; Wang, Lin; Wang, Ling; Zhuang, Hui

    2014-01-01

    This study focused on investigating the pathogenesis seen in specific-pathogen-free (SPF) rabbits following infection with a homologous rabbit HEV isolate (CHN-BJ-rb14) and comparing it to that seen following infection with a heterologous swine genotype 4 HEV isolate (CHN-XJ-SW13). Three of the four animals inoculated with the homologous rabbit HEV became infected, exhibiting an intermittent viremia, obvious fluctuations of liver function biomarkers alanine aminotransferase (ALT) and aspartate aminotransferase (AST), and persistent fecal virus shedding throughout the nine month study. In addition, liver histopathology showed both chronic inflammation and some degree of fibrosis. Both positive and negative-stranded HEV RNA and HEV antigen expression were detected in liver, brain, stomach, duodenum and kidney from the necropsied rabbits. Inflammation of extrahepatic tissue (duodenum and kidney) was also observed. Three of the four rabbits inoculated with the heterologous genotype 4 swine HEV also became infected, showing similar levels of anti-HEV antibody to that generated following infection with the homologous virus isolate. The duration of both viremia and fecal shedding of virus was however shorter following infection with the heterologous virus and there was no significant elevation of liver function biomarkers. These results suggest that rabbit HEV infection may cause more severe hepatitis and prolong the course of the disease, with a possible chronic trend of hepatitis in SPF rabbits.

  17. Serological Survey for RHD Antibodies in Rabbits from Two Types of Rabbit Breeding Farms.

    PubMed

    Fitzner, A; Niedbalski, W

    2016-09-01

    Seroprevalence studies of RHDV antibodies in domestic rabbits were conducted between 2008-2014. A total of 12,169 sera from the provinces of central, southern and south-east Poland, including 7,570 samples collected from mixed-breed rabbits reared in smallholder farms and nearly 4,600 sera taken mainly from unvaccinated rabbits kept in industrial farms, were examined using ELISA tests. Additionally, cross-reactivity of selected tested and control archival sera using both classic RHDV and RHDVa antigens was determined by HI assay. The overall seroprevalence was 13.3%. In rabbits with unkown history of immunisation or RHD infection which came from small farms, RHDV antibodies were detected in 6.1% ranging between 1.0% to 17.2% of animals. In rabbits of the same group, but with a declared vaccination status, or confirmed exposure to an infectious virus, or coming from exposed females, the seroprevalence ranged from 83% to 100%. Among unvaccinated meat rabbits aged 71 to 90 days from industrial farms, low (1.85%, 4.17%, 11%), medium (34%, 54%) or high rates (98.7%) of seropositivity were detected. The seroconversion recorded in adult vaccinated females from industrial farms was 70% and 95%. Generally, the antibody levels examined by ELISAs and HI were comparable. However, a number of sera from the rabbits from small farms, as well as archival sera, showed clear differences. Several-fold differences in antibody titers, evidenced mainly in the postoutbreak sera, indictaed the contact of animals with RHDVa antigen. The overall results of the survey revealed a great proportion of seronegative rabbits potentially highly susceptible to RHD infection. In combination with the emergence of a novel pathogenic RHD virus type (RHDV2), it poses a severe risk of a next wave of fatal disease cases spreading in the native population of domestic rabbits, especially in farms with a traditional system of husbandry.

  18. Enhanced comedo formation in rabbit ear skin by squalene and oleic acid peroxides.

    PubMed

    Motoyoshi, K

    1983-08-01

    The comedogenicity of UVA-irradiated and non-irradiated substances (squalene, oleic acid, tetradecane, isopropyl myristate, squalane and liquid paraffin) was evaluated by surface microscopy and histological examination after treating the ventral skin of rabbit ears with these substances. The lipid peroxide levels of these substances were also measured. Squalene itself was scarcely comedogenic but squalene peroxides were highly comedogenic. Both oleic acid and its peroxides were able to induce fairly large comedones and there was a good correlation between the lipid peroxide levels and the size of the comedones. The specimens biopsied from these comedones showed marked hyperplasia and hyperkeratosis of the epithelium in the follicular infundibulum and marked proliferation of the sebaceous glands. Although free fatty acids might play a role in the pathogenesis of acne, it is proposed that squalene and free fatty acids in sebum may be less comedogenic than their peroxides.

  19. Pathogenic microbes isolated from rabbit urine.

    PubMed

    Akinboade, O A; Adegoke, G O; Ogunji, F O; Nwufoh, K J

    1981-07-01

    Asymptomatic urinary tract infections were recovered from the urine of 40 of 100 rabbits, and identical bacteria were isolated when the rabbits were retested. Urine samples which yielded significant growths of bacteria also had pus cells. Some specimens yielded more than 2 different isolates, and staphylococci were the most frequently isolated bacteria. Oxalate and uric acid crystals were seen in 6% of the samples, particularly those with significant growths of Pseudomonas aeruginosa. No ova, parasites or fungal elements were seen in 'wet-mount' preparations and no fungi were seen when urine samples were cultured. Female rabbits showed a higher number of bacterial isolates than males. Animals with significant isolates were treated with suitable antibiotics and repeat samples yielded no growth.

  20. Light stimulation of iris tyrosinase in vivo. [Rabbits

    SciTech Connect

    Dryja, T.P.; Kimball, G.P.; Albert, D.M.

    1980-05-01

    This paper presents evidence that light stimulates tyrosinase activity in iris melanocytes in rabbits. Levels of iris tyrosinase were found to be greater in eyes of rabbits exposed to light for 6 weeks than in eyes of rabbits maintained in darkness. Despite increasing tyrosinase levels, exposure to light produced no clinically observable change in iris color.