Are point-of-care (POC) virological tests what is needed?
Madeley, C R
2007-07-01
Point-of-care (POC) tests are becoming more available, although the way in which they should be used is currently undecided. Any 'laboratory'-based diagnosis of respiratory infections has three components: the specimen taken, the test used, and the interpretation of the results. Each of these components needs to be carefully addressed when using POC tests for the diagnosis of respiratory tract infections. Given the enthusiasm with which POC tests are being developed, it is likely that they will be used more and more widely. If so, the advantages and limitations of their use should be fully discussed and the implications recognised.
The use of upconverting phosphors in point-of-care (POC) testing
NASA Astrophysics Data System (ADS)
Tanke, Hans J.; Zuiderwijk, Michel; Wiesmeijer, Karien C.; Breedveld, Robert N.; Abrams, William R.; de Dood, Claudia J.; Tjon Kon Fat, Elisa M.; Corstjens, Paul L. A. M.
2014-03-01
Point-of-care (POC) testing is increasingly applied as a cost effective alternative to many diagnostic tests. Key in POC testing is to create sufficient assay sensitivity with relatively low cost reagents and equipment. For this purpose we have employed a unique reporter, upconverting phosphor (UCP) particles, in combination with lateral flow (LF) assays. UCPs, submicron ceramic particles doped with rare earth ions (lanthanides), convert infrared to visible light and do not suffer from autofluorescence which limits conventional fluorescence based assays. Low cost handheld readers and microfluidics were evaluated in various applications. Designed assays are well suited for applications outside diagnostic laboratories, in resource poor settings, and can even be used by patients at home. Using two distinctly different UCP-LF assay formats, we focussed on assays for infectious diseases based on the detection of pathogen-specific antibodies and/or antigens including nucleic acids to demonstrate active infection with HIV. Only minor adaptation of the standard UCP-LF assay format is needed to render the format suitable for applications involving low affinity capture antibodies (e.g. in the detection of neurotoxin, botulism), capture of small molecules (e.g. detection of melatonin, a key hormone in chronopharmacology) or the use of dry UCP reagents (e.g. detection of protein based fruit-ripening markers, of economic interest in agriculture). Finally, we anticipate on developments in healthcare (personalized medicine) by discussing the potential of one of the UCP-LF assay formats to measure serum trough levels of immunodrugs (e.g. infliximab or adalimumab) in patients treated for inflammatory bowel disease and rheumatoid arthritis.
Enhancing crisis standards of care using innovative point-of-care testing.
Kost, Gerald J; Sakaguchi, Ann; Curtis, Corbin; Tran, Nam K; Katip, Pratheep; Louie, Richard F
2011-01-01
To identify strategies with tactics that enable point-of-care (POC) testing (medical testing at or near the site of care) to effectively improve outcomes in emergencies, disasters, and public health crises, especially where community infrastructure is compromised. Logic model-critical path-feedback identified needs for improving practices. Reverse stress analysis showed POC should be integrated, responders should be properly trained, and devices should be staged in small-world networks (SWNs). First responder POC resources were summarized, test clusters were strategized, assay environmental vulnerabilities were assessed, and tactics useful for SWNs, alternate care facilities, shelters, point-of-distribution centers, and community hospitals were designed. PARTICIPANTS AND ENVIRONMENT: Emergency-disaster needs assessment survey respondents and Center experience. Important tactics are as follows: a) develop training/education courses and '"just-in-time" on-line web resources to ensure the competency of POC coordinators and high-quality testing performance; b) protect equipment from environmental extremes by sealing reagents, by controlling temperature and humidity to which they are exposed, and by establishing near-patient testing in defined environments that operate within current Food and Drug Administration licensing claims (illustrated with human immunodeficiency virus-1/2 tests); c) position testing in defined sites within SWNs and other environments; d) harden POC devices and reagents to withstand wider ranges of environmental extremes in field applications; e) promote new POC technologies for pathogen detection and other assays, per needs assessment results; and f) select tests according to mission objectives and value propositions. Careful implementation of POC testing will facilitate evidence-based triage, diagnosis, treatment, and monitoring of victims and patients, while advancing standards of care in emergencies and disasters, as well as public health
ENHANCING CRISIS STANDARDS OF CARE USING INNOVATIVE POINT-OF-CARE TESTING
Kost, Gerald J.; Sakaguchi, Ann; Curtis, Corbin; Tran, Nam K.; Katip, Pratheep; Louie, Richard F.
2011-01-01
Objective To identify strategies with tactics that enable point-of-care (POC) testing (medical testing at or near the site of care) to improve outcomes effectively in emergencies, disasters, and public health crises, especially where community infrastructure is compromised. Design Logic model-critical path-feedback identified needs for improving practices. Reverse stress analysis showed POC should be integrated, responders properly trained, and devices staged in small-world networks (SWNs). We summarize first responder POC resources, strategize test clusters, address assay environmental vulnerabilities, and design tactics useful for SWNs, alternate care facilities, shelters, point-of-distribution centers, and community hospitals. Participants and Environment Emergency-disaster needs assessment survey respondents and Center experience. Outcomes Important tactics are: a) develop training/education courses and “just-in-time” on-line web resources to assure the competency of POC coordinators and high quality testing performance; b) protect equipment from environmental extremes by sealing reagents, controlling temperature and humidity to which they are exposed, and establishing near-patient testing in defined environments that operate within current FDA licensing claims (illustrated with HIV-1/2 tests); c) position testing in defined sites within SWNs and other environments; d) harden POC devices and reagents to withstand wider ranges of environmental extremes in field applications; e) promote new POC technologies for pathogen detection and other assays, per needs assessment results; and f) select tests according to mission objectives and value propositions. Conclusions Careful implementation of POC testing will facilitate evidence-based triage, diagnosis, treatment, and monitoring of victims and patients, while advancing standards of care in emergencies and disasters, as well as public health crises. PMID:22338316
[Point-of-care Coagulation Testing in Neurosurgery].
Adam, Elisabeth Hannah; Füllenbach, Christoph; Lindau, Simone; Konczalla, Jürgen
2018-06-01
Disorders of the coagulation system can seriously impact the clinical course and outcome of neurosurgical patients. Due to the anatomical location of the central nervous system within the closed skull, bleeding complications can lead to devastating consequences such as an increase in intracranial pressure or enlargement of intracranial hematoma. Point-of-care (POC) devices for the testing of haemostatic parameters have been implemented in various fields of medicine. Major advantages of these devices are that results are available quickly and that analysis can be performed at the bedside, directly affecting patient management. POC devices allow identification of increased bleeding tendencies and therefore may enable an assessment of hemorrhagic risks in neurosurgical patients. Although data regarding the use of POC testing in neurosurgical patients are limited, they suggest that coagulation testing and hemostatic therapy using POC devices might have beneficial effects in this patient population. This article provides an overview of the application of point-of-care coagulation testing in clinical practice in neurosurgical patients. Georg Thieme Verlag KG Stuttgart · New York.
Point of care testing: The impact of nanotechnology.
Syedmoradi, Leila; Daneshpour, Maryam; Alvandipour, Mehrdad; Gomez, Frank A; Hajghassem, Hassan; Omidfar, Kobra
2017-01-15
Point-of-care (POC) diagnostic devices are integral in the health care system and particularly for the diagnosis and monitoring of diseases. POC testing has a variety of advantages including the ability to provide rapid and accurate results, ease of use, low cost, and little need for specialized equipment. One of the goals of POC testing is the development of a chip-based, miniaturized, portable, and self-containing system that allows for the assay of different analytes in complex samples. To achieve these goals, many researchers have focused on paper-based and printed electrode technologies as the material for fabricating POC diagnostic systems. These technologies are affordable, sensitive, user-friendly, rapid, and scalable for manufacturing. Moreover, the combination such devices with nanomaterials provide a path for the development of highly sensitive and selective biosensors for future generation POC tools. This review article discusses present technologies in on-site or at home POC diagnostic assays implemented in paper-based microfluidic and screen printing devices over the past decade as well as in the near future. In addition, recent advances in the application of nanomaterials such as gold nanoparticles, carbon nanotubes (CNTs), magnetic nanoparticles, and graphene in POC devices will be reviewed. The factors that limit POC testing to become real world products and future directions are also identified. Copyright © 2016 Elsevier B.V. All rights reserved.
Evaluating Diagnostic Point-of-Care Tests in Resource-Limited Settings
Drain, Paul K; Hyle, Emily P; Noubary, Farzad; Freedberg, Kenneth A; Wilson, Douglas; Bishai, William; Rodriguez, William; Bassett, Ingrid V
2014-01-01
Diagnostic point-of-care (POC) testing is intended to minimize the time to obtain a test result, thereby allowing clinicians and patients to make an expeditious clinical decision. As POC tests expand into resource-limited settings (RLS), the benefits must outweigh the costs. To optimize POC testing in RLS, diagnostic POC tests need rigorous evaluations focused on relevant clinical outcomes and operational costs, which differ from evaluations of conventional diagnostic tests. Here, we reviewed published studies on POC testing in RLS, and found no clearly defined metric for the clinical utility of POC testing. Therefore, we propose a framework for evaluating POC tests, and suggest and define the term “test efficacy” to describe a diagnostic test’s capacity to support a clinical decision within its operational context. We also proposed revised criteria for an ideal diagnostic POC test in resource-limited settings. Through systematic evaluations, comparisons between centralized diagnostic testing and novel POC technologies can be more formalized, and health officials can better determine which POC technologies represent valuable additions to their clinical programs. PMID:24332389
Evidence-based point-of-care tests and device designs for disaster preparedness.
Brock, T Keith; Mecozzi, Daniel M; Sumner, Stephanie; Kost, Gerald J
2010-01-01
To define pathogen tests and device specifications needed for emerging point-of-care (POC) technologies used in disasters. Surveys included multiple-choice and ranking questions. Multiple-choice questions were analyzed with the chi2 test for goodness-of-fit and the binomial distribution test. Rankings were scored and compared using analysis of variance and Tukey's multiple comparison test. Disaster care experts on the editorial boards of the American Journal of Disaster Medicine and the Disaster Medicine and Public Health Preparedness, and the readers of the POC Journal. Vibrio cholera and Staphylococcus aureus were top-ranked pathogens for testing in disaster settings. Respondents felt that disaster response teams should be equipped with pandemic infectious disease tests for novel 2009 H1N1 and avian H5N1 influenza (disaster care, p < 0.05; POC, p < 0.01). In disaster settings, respondents preferred self-contained test cassettes (disaster care, p < 0.05; POC, p < 0.001) for direct blood sampling (POC, p < 0.01) and disposal of biological waste (disaster care, p < 0.05; POC, p < 0.001). Multiplex testing performed at the POC was preferred in urgent care and emergency room settings. Evidence-based needs assessment identifies pathogen detection priorities in disaster care scenarios, in which Vibrio cholera, methicillin-sensitive and methicillin-resistant Staphylococcus aureus, and Escherichia coli ranked the highest. POC testing should incorporate setting-specific design criteria such as safe disposable cassettes and direct blood sampling at the site of care.
Kaman, Wendy E; Andrinopoulou, Eleni-Rosalina; Hays, John P
2013-01-01
The proper development and implementation of point-of-care (POC) diagnostics requires knowledge of the perceived requirements and barriers to their implementation. To determine the current requirements and perceived barriers to the introduction of POC diagnostics in the field of medical microbiology (MM)-POC a prospective online survey (TEMPOtest-QC) was established. The TEMPOtest-QC survey was online between February 2011 and July 2012 and targeted the medical community, POC test diagnostic manufacturers, general practitioners, and the general public. In total, 293 individuals responded to the survey, including 91 (31%) medical microbiologists, 39 (13%) nonmedical microbiologists, 25 (9%) employees of POC test manufacturers, and 138 (47%) members of the general public. Responses were received from 18 different European countries, with the largest percentage of these living in The Netherlands (52%). The majority (>50%) of medical specialists regarded the development of MM-POC for blood culture and hospital acquired infections as "absolutely necessary", but were much less favorable towards their use in the home environment. Significant differences in perceptions between medical specialists and the general public included the: (1) Effect on quality of patient care; (2) Ability to better monitor patients; (3) Home testing and the doctor-patient relationship; and (4) MM-POC interpretation. Only 34.7% of the general public is willing to pay more than a€10 ($13) for a single MM-POC test, with 85.5% preferring to purchase their MM-POC test from a pharmacy. The requirements for the proper implementation of MM-POC were found to be generally similar between medical specialists and POC test kit manufacturers. The general public was much more favorable with respect to a perceived improvement in the quality of healthcare that these tests would bring to the hospital and home environment.
Economic evaluations of point of care testing strategies for active tuberculosis.
Zwerling, Alice; Dowdy, David
2013-06-01
Point of care (POC) diagnostics are often hailed as having the potential to transform tuberculosis (TB) control efforts. However, POC testing is better conceptualized as a system of diagnosis and treatment, not simply a test that can provide rapid, deployable results. Economic evaluations may help decision makers allocate scarce resources for TB control, but evaluations of POC testing face unique challenges that include evaluating the full diagnostic system, incorporating implementation costs, translating diagnostic results into health and accounting for downstream treatment costs. For economic evaluations to reach their full potential as decision-making tools for POC testing in TB, these challenges must be understood and addressed.
Cost-effectiveness of point-of-care testing for dehydration in the pediatric ED.
Whitney, Rachel E; Santucci, Karen; Hsiao, Allen; Chen, Lei
2016-08-01
Acute gastroenteritis (AGE) and subsequent dehydration account for a large proportion of pediatric emergency department (PED) visits. Point-of-care (POC) testing has been used in conjunction with clinical assessment to determine the degree of dehydration. Despite the wide acceptance of POC testing, little formal cost-effective analysis of POC testing in the PED exists. We aim to examine the cost-effectiveness of using POC electrolyte testing vs traditional serum chemistry testing in the PED for children with AGE. This was a cost-effective analysis using data from a randomized control trial of children with AGE. A decision analysis model was constructed to calculate cost-savings from the point of view of the payer and the provider. We used parameters obtained from the trial, including cost of testing, admission rates, cost of admission, and length of stay. Sensitivity analyses were performed to evaluate the stability of our model. Using the data set of 225 subjects, POC testing results in a cost savings of $303.30 per patient compared with traditional serum testing from the point of the view of the payer. From the point-of-view of the provider, POC testing results in consistent mean savings of $36.32 ($8.29-$64.35) per patient. Sensitivity analyses demonstrated the stability of the model and consistent savings. This decision analysis provides evidence that POC testing in children with gastroenteritis-related moderate dehydration results in significant cost savings from the points of view of payers and providers compared to traditional serum chemistry testing. Copyright © 2016 Elsevier Inc. All rights reserved.
Reif, Philipp; Lakovschek, Ioanna; Tappauf, Carmen; Haas, Josef; Lang, Uwe; Schöll, Wolfgang
2014-06-01
Although fetal blood sampling for pH is well established the use of lactate has not been widely adopted. This study validated the performance and utility of a handheld point-of-care (POC) lactate device in comparison with the lactate and pH values obtained by the ABL 800 blood gas analyzer. The clinical performance and influences on accuracy and decision-making criteria were assessed with freshly taken fetal blood scalp samples (n=57) and umbilical cord samples (n=310). Bland-Altman plot was used for data plotting and analyzing the agreement between the two measurement devices and correlation coefficients (R²) were determined using Passing-Bablok regression analysis. Sample processing errors were much lower in the testing device (22.8% vs. 0.5%). Following a preclinical assessment and calibration offset alignment (0.5 mmol/L) the test POC device showed good correlation with the reference method for lactate FBS (R²=0.977, p<0.0001, 95% CI 0.9 59-0.988), arterial cord blood (R²=0.976, p<0.0001, 95% CI 0.967-0.983) and venous cord blood (R²=0.977, p<0.0001, 95% CI 0.968-0.984). A POC device which allows for a calibration adjustment to be made following preclinical testing can provide results that will correlate closely to an incumbent lactate method such as a blood gas analyzer. The use of a POC lactate device can address the impracticality and reality of pH sample collection and testing failures experienced in day to day clinical practice. For the StatStrip Lactate meter we suggest using a lactate cut-off of 5.1 mmol/L for predicting fetal acidosis (pH<7.20).
Cost-Effectiveness of POC Coagulation Testing Using Multiple Electrode Aggregometry.
Straub, Niels; Bauer, Ekaterina; Agarwal, Seema; Meybohm, Patrick; Zacharowski, Kai; Hanke, Alexander A; Weber, Christian F
2016-01-01
The economic effects of Point-of-Care (POC) coagulation testing including Multiple Electrode Aggregometry (MEA) with the Multiplate device have not been examined. A health economic model with associated clinical endpoints was developed to calculate the effectiveness and estimated costs of coagulation analyses based on standard laboratory testing (SLT) or POC testing offering the possibility to assess platelet dysfunction using aggregometric measures. Cost estimates included pre- and perioperative costs of hemotherapy, intra- and post-operative coagulation testing costs, and hospitalization costs, including the costs of transfusion-related complications. Our model calculation using a simulated true-to-life cohort of 10,000 cardiac surgery patients assigned to each testing alternative demonstrated that there were 950 fewer patients in the POC branch who required any transfusion of red blood cells. The subsequent numbers of massive transfusions and patients with transfusion-related complications were reduced with the POC testing by 284 and 126, respectively. The average expected total cost in the POC branch was 288 Euro lower for every treated patient than that in the SLT branch. Incorporating aggregometric analyses using MEA into hemotherapy algorithms improved medical outcomes in cardiac surgery patients in the presented health economic model. There was an overall better economic outcome associated with POC testing compared with SLT testing despite the higher costs of testing.
Hirst, J A; Stevens, R J; Smith, I; James, T; Gudgin, B C; Farmer, A J
2017-08-01
Point-of-care (POC) HbA1c testing gives a rapid result, allowing testing and treatment decisions to take place in a single appointment. Trials of POC testing have not been shown to improve HbA1c, possibly because of how testing was implemented. This study aimed to identify key components of POC HbA1c testing and determine strategies to optimise implementation in UK primary care. This cohort feasibility study recruited thirty patients with type 2 diabetes and HbA1c>7.5% (58mmol/mol) into three primary care clinics. Patients' clinical care included two POC HbA1c tests over six months. Data were collected on appointment duration, clinical decisions, technical performance and patient behaviour. Fifty-three POC HbA1c consultations took place during the study; clinical decisions were made in 30 consultations. Five POC consultations with a family doctor lasted on average 11min and 48 consultations with nurses took on average 24min. Five POC study visits did not take place in one clinic. POC results were uploaded to hospital records from two clinics. In total, sixty-three POC tests were performed, and there were 11 cartridge failures. No changes in HbA1c or patient behaviour were observed. HbA1c measurement with POC devices can be effectively implemented in primary care. This work has identified when these technologies might work best, as well as potential challenges. The findings can be used to inform the design of a pragmatic trial to implement POC HbA1c testing. Copyright © 2017 The Authors. Published by Elsevier B.V. All rights reserved.
The universe of ANA testing: a case for point-of-care ANA testing.
Konstantinov, Konstantin N; Rubin, Robert L
2017-12-01
Testing for total antinuclear antibodies (ANA) is a critical tool for diagnosis and management of autoimmune diseases at both the primary care and subspecialty settings. Repurposing of ANA from a test for lupus to a test for any autoimmune condition has driven the increase in ANA requests. Changes in ANA referral patterns include early or subclinical autoimmune disease detection in patients with low pre-test probability and use of negative ANA results to rule out underlying autoimmune disease. A positive result can lead to further diagnostic considerations. Currently, ANA tests are performed in centralized laboratories; an alternative would be ANA testing at the clinical point-of-care (POC). By virtue of its near real-time data collection capability, low cost, and ease of use, we believe the POC ANA has the potential to enable a new paradigm shift in autoimmune serology testing.
Tucker, Joseph D; Bien, Cedric H; Peeling, Rosanna W
2013-02-01
Sexually transmitted infections (STIs) remain a major global public health issue, with more than 448 million incident bacterial infections each year. We review recent advances in STI point-of-care (POC) testing and implications for STI prevention and control. Accurate immunochromatographic assays to detect HIV, hepatitis C virus (HCV) and syphilis antibodies have made home or supervised self-testing possible. Several studies have demonstrated feasibility and excellent test characteristics for HIV, HCV and syphilis POC tests. Rapid oral HIV tests are now available for purchase at retail sites across the United States. Combined HIV and syphilis tests using a single finger prick blood sample are under evaluation. Oral POC STI tests with comparable performance to blood-based POC tests are available for self-testing. POC tests can expand screening, improve syndromic management and reduce loss to follow up. POC STI tests have the potential to facilitate prompt treatment and partner services. POC STI tests create opportunities for new social and financial models of community-based testing services. Increasing equity and access to testing will create challenges in linkage to care, quality assurance, partner services and surveillance. These important developments warrant research to understand appropriate contexts for implementation.
Bezerra, Fernando Schemelzer Moraes; Leal, Joames Kauffimann Freitas; Sousa, Mariana Silva; Pinheiro, Marta Cristhiany Cunha; Ramos, Alberto Novaes; Silva-Moraes, Vanessa; Katz, Naftale
2018-06-01
Schistosomiasis is still a public health problem in Brazil. The Kato-Katz test is the most frequently used diagnostic method for Schistosoma mansoni infection. However, it lacks sensitivity in areas of low prevalence. We have assessed the positivity rate of S. mansoni infection in Bananeiras, a village on Capistrano, Ceara, Brazil by performing a point-of-care test in urine to determine the circulating cathodic antigens (POC-CCA), and we compared the findings with those of the Kato-Katz technique for egg detection in stool and an enzyme-linked immunosorbent assay for specific antibodies against adult worms (SWAP-ELISA) in serum before treatment (baseline). Additionally, the POC-CCA and Kato-Katz test results were compared at one and two years post-treatment, and only POC-CCA strips were utilised for follow-up testing on urine samples at 3-6 weeks. Only one sample of stool and urine was collected per event. Overall, 258 individuals were investigated at the baseline. The POC-CCA test detected 10 (3.9%) positive cases; however, this amount increased to 30 (11.6%) when considering trace readings as positive (t + ), whereas the Kato-Katz method found only 4 (1.6%) positive cases and the SWAP-ELISA detected 105 (40.7%) positive cases. The consistency observed between a single POC-CCA (t + ) or (t-) and the Kato-Katz (three slides) was poor (Kappa indexes <0.20). The highest positivity rate as determined by CCA and Kato-Katz was found in adults. At the baseline, a praziquantel treatment was administered to all individuals regardless of their infection status. According to the POC-CCA test, 93% of the previous positive cases became negative by the third week after the treatment; this rate reached 100% at the sixth week assessment. The follow-up showed that of the 175 individuals evaluated at one year post-treatment, only one (0.6%) showed 'trace' results, and all the individuals were negative for eggs in the stool. At two years, all 185 examined individuals were
Larson, Bruce A; Schnippel, Kathryn; Ndibongo, Buyiswa; Xulu, Thembisile; Brennan, Alana; Long, Lawrence; Fox, Matthew P; Rosen, Sydney
2012-10-01
A mobile HIV counseling and testing (HCT) program around Johannesburg piloted the integration of point-of-care (POC) CD4 testing, using the Pima analyzer, to improve linkages to HIV care. We report results from this pilot program for patients testing positive (n = 508) from May to October 2010. We analyzed 3 primary outcomes: assignment to testing group (offered POC CD4 or not), successful follow-up (by telephone), and completed the referral visit for HIV care within 8 weeks after HIV testing if successfully followed up. Proportions for each outcome were calculated, and relative risks were estimated using a modified Poisson approach. Three hundred eleven patients were offered the POC CD4 test, and 197 patients were not offered the test. No differences in patient characteristics were observed between the 2 groups. Approximately 62.7% of patients were successfully followed up 8 weeks after HIV testing, with no differences observed between testing groups. Among those followed up, 54.4% reported completing their referral visit. Patients offered the POC CD4 test were more likely to complete the referral visit for further HIV care (relative risk 1.25, 95% confidence interval: 1.00 to 1.57). In this mobile HCT setting, patients offered POC CD4 testing as part of the HCT services were more likely to visit a referral clinic after testing, suggesting that rapid CD4 testing technology may improve linkage to HIV care. Future research can evaluate options for adjusting HCT services if POC CD4 testing was included permanently and the cost-effectiveness of the POC CD4 testing compared with other approaches for improving linkage of care.
Tucker, Joseph D.; Bien, Cedric H.; Peeling, Rosanna W.
2013-01-01
Purpose of review Sexually transmitted infections (STIs) remain a major global public health issue, with more than 448 million incident bacterial infections each year. We review recent advances in STI point-of-care (POC) testing and implications for STI prevention and control. Recent findings Accurate immunochromatographic assays to detect HIV, hepatitis C virus (HCV) and syphilis antibodies have made home or supervised self-testing possible. Several studies have demonstrated feasibility and excellent test characteristics for HIV, HCV and syphilis POC tests. Rapid oral HIV tests are now available for purchase at retail sites across the United States. Combined HIV and syphilis tests using a single finger prick blood sample are under evaluation. Summary Oral POC STI tests with comparable performance to blood-based POC tests are available for self-testing. POC tests can expand screening, improve syndromic management and reduce loss to follow up. POC STI tests have the potential to facilitate prompt treatment and partner services. POC STI tests create opportunities for new social and financial models of community-based testing services. Increasing equity and access to testing will create challenges in linkage to care, quality assurance, partner services and surveillance. These important developments warrant research to understand appropriate contexts for implementation. PMID:23242343
A Novel Field-Deployable Point-of-Care Diagnostic Test for Cutaneous Leishmaniasis
2017-10-01
AWARD NUMBER: W81XWH-14-2-0195 TITLE: A Novel Field-Deployable Point-of-Care Diagnostic Test for Cutaneous Leishmaniasis PRINCIPAL INVESTIGATOR...Field-Deployable Point-of-Care Diagnostic Test for Cutaneous Leishmaniasis 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR(S...Month % completion Aim 1: To use simulated field conditions to optimize and produce the established RPA lateral flow diagnostic test for POC
Cholesterol Point-of-Care Testing for Community Pharmacies: A Review of the Current Literature.
Haggerty, Lauren; Tran, Deanna
2017-08-01
To summarize the literature on cholesterol point-of-care tests (POCTs). This article would serve as a resource to assist community pharmacists in developing cholesterol point-of-care (POC) pharmacy services. A literature search was performed in MEDLINE Ovid, PubMed, EMBASE, and Cochrane database using the following medical subject headings (MeSH) terms: point-of-care test, cholesterol, blood chemical analysis, rapid testing, collaborative practice, community pharmacy, and ambulatory care. Additional resources including device manufacturer web sites were summarized to supplement the current literature. All human research articles, review articles, meta-analyses, and abstracts published in English through September 1, 2014, were considered. A total of 36 articles were applicable for review. Information was divided into the following categories to be summarized: devices, pharmacists' impact, and operational cost for the pharmacy. The current literature suggests that POCTs in community pharmacies assist with patient outcomes by providing screenings and referring patients with dyslipidemia for further evaluation. The majority of studies on cholesterol POC devices focused on accuracy, revealing the need for further studies to develop best practices and practice models with successful reimbursement. Accuracy, device specifications, required supplies, and patient preference should be considered when selecting a POC device for purchase.
Routine use of point-of-care tests: usefulness and application in clinical microbiology.
Clerc, O; Greub, G
2010-08-01
Point-of-care (POC) tests offer potentially substantial benefits for the management of infectious diseases, mainly by shortening the time to result and by making the test available at the bedside or at remote care centres. Commercial POC tests are already widely available for the diagnosis of bacterial and viral infections and for parasitic diseases, including malaria. Infectious diseases specialists and clinical microbiologists should be aware of the indications and limitations of each rapid test, so that they can use them appropriately and correctly interpret their results. The clinical applications and performance of the most relevant and commonly used POC tests are reviewed. Some of these tests exhibit insufficient sensitivity, and should therefore be coupled to confirmatory tests when the results are negative (e.g. Streptococcus pyogenes rapid antigen detection test), whereas the results of others need to be confirmed when positive (e.g. malaria). New molecular-based tests exhibit better sensitivity and specificity than former immunochromatographic assays (e.g. Streptococcus agalactiae detection). In the coming years, further evolution of POC tests may lead to new diagnostic approaches, such as panel testing, targeting not just a single pathogen, but all possible agents suspected in a specific clinical setting. To reach this goal, the development of serology-based and/or molecular-based microarrays/multiplexed tests will be needed. The availability of modern technology and new microfluidic devices will provide clinical microbiologists with the opportunity to be back at the bedside, proposing a large variety of POC tests that will allow quicker diagnosis and improved patient care.
Howick, Jeremy; Cals, Jochen W L; Jones, Caroline; Price, Christopher P; Plüddemann, Annette; Heneghan, Carl; Berger, Marjolein Y; Buntinx, Frank; Hickner, John; Pace, Wilson; Badrick, Tony; Van den Bruel, Ann; Laurence, Caroline; van Weert, Henk C; van Severen, Evie; Parrella, Adriana; Thompson, Matthew
2014-01-01
Objective Despite the growing number of point-of-care (POC) tests available, little research has assessed primary care clinician need for such tests. We therefore aimed to determine which POC tests they actually use or would like to use (if not currently available in their practice). Design Cross-sectional survey. Setting Primary care in Australia, Belgium (Flanders region only), the Netherlands, the UK and the USA. Participants Primary care doctors (general practitioners, family physicians). Main measures We asked respondents to (1) identify conditions for which a POC test could help inform diagnosis, (2) from a list of tests provided: evaluate which POC tests they currently use (and how frequently) and (3) determine which tests (from that same list) they would like to use in the future (and how frequently). Results 2770 primary care clinicians across five countries responded. Respondents in all countries wanted POC tests to help them diagnose acute conditions (infections, acute cardiac disease, pulmonary embolism/deep vein thrombosis), and some chronic conditions (diabetes, anaemia). Based on the list of POC tests provided, the most common tests currently used were: urine pregnancy, urine leucocytes or nitrite and blood glucose. The most commonly reported tests respondents expressed a wish to use in the future were: D-dimer, troponin and chlamydia. The UK and the USA reported a higher actual and desired use for POC tests than Australia, Belgium and the Netherlands. Our limited data suggest (but do not confirm) representativeness. Conclusions Primary care clinicians in all five countries expressed a desire for POC tests to help them diagnose a range of acute and chronic conditions. Rates of current reported use and desired future use were generally high for a small selection of POC tests, but varied across countries. Future research is warranted to explore how specific POC tests might improve primary care. PMID:25107438
Point-of-care diagnostics: market trends and growth drivers.
Rajan, Aruna; Glorikian, Harry
2009-01-01
There is a significant demand for in vitro diagnostic (IVD) testing to move closer to the patient point-of-care diagnostics [POC]), whether in the hospital, physician's office, rapid clinic or the home, effectively cutting time to results and helping patients make better informed decisions about their health. To analyze the point-of-care market and its trends and growth drivers. In 2007, POC made up 30% of the IVD market and is expected to grow at 9% a year. Although the overall POC market is expected to grow steadily, infectious POC is now the most attractive segment. Availability of rapid random access molecular diagnostic system for critical care infectious diseases such as MRSA and sepsis in the near future is likely to be a significant driver of infectious POC post 2012. Owing to the extraordinary increase in the cost of care, healthcare delivery is moving to increasingly decentralized settings such as rapid clinics and the home, driven by point-of-care diagnostics that provide accurate and directional results. We are evolving from the analog testing world to the digital testing world, where diagnosis is exact and therapy can be administered and be predictably effective.
Bronner Murrison, Liza; Ananthakrishnan, Ramya; Sukumar, Sumanya; Augustine, Sheela; Krishnan, Nalini; Pai, Madhukar; Dowdy, David W
2016-01-01
Private practitioners are frequently the first point of healthcare contact for patients with tuberculosis (TB) in India. As new molecular tests are developed for point-of-care (POC) diagnosis of TB, it is imperative to understand these individuals' practices and preferences for POC testing. To evaluate rapid testing practices and identify priorities for novel POC TB tests among private practitioners in Chennai. We conducted a cross-sectional survey of 228 practitioners practicing in the private sector from January 2014 to February 2015 who saw at least one TB patient in the previous year. Practitioners were randomly selected from both the general community and a list of practitioners who referred patients to a public-private mix program for TB treatment. We used standardized questionnaires to collect data on current practices related to point-of-care diagnosis and interest in hypothetical POC tests. We used multivariable Poisson regression with robust estimates of standard error to calculate measures of association. Among 228 private practitioners, about half (48%) utilized any rapid testing in their current practice, most commonly for glucose (43%), pregnancy (21%), and malaria (5%). Providers using POC tests were more likely to work in hospitals (56% vs. 43%, P = 0.05) and less likely to be chest specialists (21% vs. 54%, P<0.001). Only half (51%) of providers would use a hypothetical POC test for TB that was accurate, equipment-free, and took 20 minutes to complete. Chest specialists were half as likely to express interest in performing the hypothetical POC TB test in-house as other practitioners (aPR 0.5, 95%CI: 0.2-0.9). Key challenges to performing POC testing for TB in this study included time constraints, easy access to local private labs and lack of an attached lab facility. As novel POC tests for TB are developed and scaled up, attention must be paid to integrating these diagnostics into healthcare providers' routine practice and addressing barriers for
BRIEF REPORT: The Role of Point of Care Testing for Patients with Acute Pharyngitis
Atlas, Steven J; McDermott, Steven M; Mannone, Carol; Barry, Michael J
2005-01-01
Background There is no consensus favoring a particular strategy for evaluating patients with pharyngitis. Objective To compare a clinical decision aid and a rapid office-based point of care (POC) test with routine culture for group A β-hemolytic streptococcus (GAS). Design Prospective observational study. Participants Among 179 patients enrolled, 150 were eligible and 148 had POC testing and cultures initially performed. Measurements An encounter form included eligibility criteria, clinical information based upon the Centor rule, and treatment provided. Sensitivity and specificity of POC test compared to routine culture for GAS. Results Thirty-eight patients (25.7%) had a positive GAS culture. The POC test was 92.1% sensitive (95% confidence interval [CI] 80% to 98%) and 100% specific (95% CI 97% to 100%). Although the Centor rule did not adequately discriminate among symptomatic patients with or without GAS (receiver operating curve area 0.63), the 3 patients with a false-negative POC test had a Centor score of less than 2. Among patients with a negative POC test, 26% initially received antibiotics. Conclusions For patients with a Centor score of ≥2, a POC test was highly sensitive for GAS. Future studies should confirm these results and assess whether implementation of POC testing as part of a local practice guideline can decrease variability in testing and treatment. PMID:16050888
Brook, Gary
2015-12-01
To identify point-of-care (POC) and rapid nucleic acid amplification techniques (NAATs) for the diagnosis of chlamydia and gonorrhoea and assess their utility. Literature search for available POC and rapid NAATs. The performance from the best-performing assays were applied hypothetically to patients in the clinic in which 100 consecutive patients with chlamydia and 100 with gonorrhoea were diagnosed in 1737 and 4575 patients respectively, with 44/100 and 54/100 treated at first attendance, respectively. 11 POC and 1 rapid NAAT were identified. Published performances for the best POC for chlamydia (CRT) were: sensitivity 41%-87%, specificity 89%-99.6%. Our data suggest that if this assay was used instead of our current NAAT, for every 100 patients diagnosed currently, 23-46 extra patients would be treated at first attendance; 10-35 would go undiagnosed with 7-191 false-positives. Best chlamydia rapid NAAT (GeneXpert): sensitivity 97.5%-98.7%, specificity 99.4%-99.9%. Anticipated performance for every 100 patients diagnosed currently: 0 extra patients treated at first attendance, 1-3 undiagnosed, 0-2 false-positives. Best POC for gonorrhoea (GC Check): sensitivity 54%-70%, specificity 97%-98%. Anticipated performance for every 100 patients diagnosed currently: 14-18 extra patients treated at first attendance, 28-32 undiagnosed, 92-137 false-positives. Best rapid NAAT for gonorrhoea (GeneXpert): sensitivity 96%-100%, specificity 99.9%-100%. Anticipated performance for every 100 patients diagnosed currently: 0 extra patients treated at first attendance, 0-4 undiagnosed, 0-5 false-positives. Rapid NAAT would reduce time to treatment by 4 days for initially untreated patients. POC assays would need to be used in conjunction with a NAAT, increasing early treatment rates expense and false-positive results. The rapid NAAT could be used alone, with a reduction in average time-to-treat and a small reduction in sensitivity and specificity. Published by the BMJ Publishing
Impact of HbA1c Testing at Point of Care on Diabetes Management
Schnell, Oliver; Crocker, J. Benjamin; Weng, Jianping
2016-01-01
Diabetes is a highly prevalent disease also implicated in the development of several other serious complications like cardiovascular or renal disease. HbA1c testing is a vital step for effective diabetes management, however, given the low compliance to testing frequency and, commonly, a subsequent delay in the corresponding treatment modification, HbA1c at the point of care (POC) offers an opportunity for improvement of diabetes care. In this review, based on data from 1999 to 2016, we summarize the evidence supporting a further implementation of HbA1c testing at POC, discuss its limitations and propose recommendations for further development. PMID:27898388
Point-of-Care Hemoglobin/Hematocrit Testing: Comparison of Methodology and Technology.
Maslow, Andrew; Bert, Arthur; Singh, Arun; Sweeney, Joseph
2016-04-01
Point-of-care (POC) testing allows rapid assessment of hemoglobin (Hgb) and hematocrit (Hct) values. This study compared 3 POC testing devices--the Radical-7 pulse oximeter (Radical-7, Neuchȃtel, Switzerland), the i-STAT (Abbott Point of Care, Princeton, NJ), and the GEM 4000 (Instrumentation Laboratory, Bedford, MA)--to the hospital reference device, the UniCel DxH 800 (Beckman Coulter, Brea, CA) in cardiac surgery patients. Prospective study. Tertiary care cardiovascular center. Twenty-four consecutive elective adult cardiac surgery patients. Hgb and Hct values were measured using 3 POC devices (the Radical-7, i-STAT, and GEM 4000) and a reference laboratory device (UniCel DxH 800). Data were collected simultaneously before surgery, after heparin administration, after heparin reversal with protamine, and after sternal closure. Data were analyzed using bias analyses. POC testing data were compared with that of the reference laboratory device. Hgb levels ranged from 6.8 to 15.1 g/dL, and Hct levels ranged from 20.1% to 43.8%. The overall mean bias was lowest with the i-STAT (Hct, 0.22%; Hgb 0.05 g/dL) compared with the GEM 4000 (Hct, 2.15%; Hgb, 0.63 g/dL) and the Radical-7 (Hgb 1.16 g/dL). The range of data for the i-STAT and Radical-7 was larger than that with the GEM 4000, and the pattern or slopes changed significantly with the i-STAT and Radical-7, whereas that of the GEM 4000 remained relatively stable. The GEM 4000 demonstrated a consistent overestimation of laboratory data, which tended to improve after bypass and at lower Hct/Hgb levels. The i-STAT bias changed from overestimation to underestimation, the latter in the post-cardiopulmonary bypass period and at lower Hct/Hgb levels. By contrast, the Radical-7 biases increased during the surgical procedure and in the lower ranges of Hgb. Important clinical differences and limitations were found among the 3 POC testing devices that should caution clinicians from relying on these data as sole determinants of
Hyle, Emily P; Jani, Ilesh V; Lehe, Jonathan; Su, Amanda E; Wood, Robin; Quevedo, Jorge; Losina, Elena; Bassett, Ingrid V; Pei, Pamela P; Paltiel, A David; Resch, Stephen; Freedberg, Kenneth A; Peter, Trevor; Walensky, Rochelle P
2014-09-01
Point-of-care CD4 tests at HIV diagnosis could improve linkage to care in resource-limited settings. Our objective is to evaluate the clinical and economic impact of point-of-care CD4 tests compared to laboratory-based tests in Mozambique. We use a validated model of HIV testing, linkage, and treatment (CEPAC-International) to examine two strategies of immunological staging in Mozambique: (1) laboratory-based CD4 testing (LAB-CD4) and (2) point-of-care CD4 testing (POC-CD4). Model outcomes include 5-y survival, life expectancy, lifetime costs, and incremental cost-effectiveness ratios (ICERs). Input parameters include linkage to care (LAB-CD4, 34%; POC-CD4, 61%), probability of correctly detecting antiretroviral therapy (ART) eligibility (sensitivity: LAB-CD4, 100%; POC-CD4, 90%) or ART ineligibility (specificity: LAB-CD4, 100%; POC-CD4, 85%), and test cost (LAB-CD4, US$10; POC-CD4, US$24). In sensitivity analyses, we vary POC-CD4-specific parameters, as well as cohort and setting parameters to reflect a range of scenarios in sub-Saharan Africa. We consider ICERs less than three times the per capita gross domestic product in Mozambique (US$570) to be cost-effective, and ICERs less than one times the per capita gross domestic product in Mozambique to be very cost-effective. Projected 5-y survival in HIV-infected persons with LAB-CD4 is 60.9% (95% CI, 60.9%-61.0%), increasing to 65.0% (95% CI, 64.9%-65.1%) with POC-CD4. Discounted life expectancy and per person lifetime costs with LAB-CD4 are 9.6 y (95% CI, 9.6-9.6 y) and US$2,440 (95% CI, US$2,440-US$2,450) and increase with POC-CD4 to 10.3 y (95% CI, 10.3-10.3 y) and US$2,800 (95% CI, US$2,790-US$2,800); the ICER of POC-CD4 compared to LAB-CD4 is US$500/year of life saved (YLS) (95% CI, US$480-US$520/YLS). POC-CD4 improves clinical outcomes and remains near the very cost-effective threshold in sensitivity analyses, even if point-of-care CD4 tests have lower sensitivity/specificity and higher cost than published
Schuijt, Tim J; Boss, David S; Musson, Ruben E A; Demir, Ayse Y
2018-03-27
Bacterial resistance to antibiotics represents a serious global challenge that is associated with high morbidity and mortality. One of the most important causes of this threat is antibiotic overuse. The Dutch College of General Practitioners (DCGP) recommends the use of point-of-care (POC) testing for C-reactive protein (CRP) in two guidelines ('Acute Cough' and 'Diverticulitis') to achieve a more sensible prescription pattern of antibiotics. To evaluate the use of POC-CRP testing in light of the DCGP guidelines and the effect of CRP measurements on antibiotic prescription policy in primary care. In a prospective observational study, which included 1756 patients, general practitioners (GPs) were asked to complete a questionnaire after every POC-CRP testing, stating the indication for performing the test, the CRP result and their decision whether or not to prescribe antibiotics. Indications were verified against the DCGP guidelines and categorized. Antibiotic prescription was evaluated in relation to CRP concentrations. Indications to perform POC-CRP test and the prescription pattern of antibiotics based on CRP value varied considerably between GPs. Differences in antibiotic prescription rate were most obvious in patients who presented with CRP values between 20 and 100 mg/l, and could in part be explained by the indication for performing POC-CRP test and patient age. Most GPs followed the DCGP guidelines and used low CRP values to underpin their decision to refrain from antibiotic prescription. Peer-based reflection on differences in POC-CRP usage and antibiotic prescription rate amongst GPs may further nourish a more critical approach to prescription of antibiotics.
The introduction of syphilis point of care tests in resource limited settings.
Marks, Michael; Mabey, David Cw
2017-04-01
Syphilis remains an important and preventable cause of stillbirth and neonatal mortality. About 1 million women with active syphilis become pregnant each year. Without treatment, 25% of them will deliver a stillborn baby and 33% a low birth weight baby with an increased chance of dying in the first month of life. Adverse pregnancy outcomes due to syphilis can be prevented by screening pregnant women, and treating those who test positive with a single dose of penicillin before 28 weeks' gestation. Areas covered: This manuscript covers the impact of syphilis on pregnancy outcome, the diagnosis of syphilis, with a special focus on point of care (POC) tests, and challenges to the introduction of POC tests, and their potential impact on the control and prevention of syphilis in resource limited settings. Expert commentary: POC tests for syphilis are available which meet the ASSURED criteria, and could make syphilis screening accessible to all women anywhere in the world who attend an antenatal clinic. High quality dual POC tests for HIV and syphilis could ensure that well-funded programmes for the prevention of mother to child transmission of HIV can contribute towards increased coverage of antenatal syphilis screening, and prevent more than 300,000 adverse pregnancy outcomes due to syphilis annually. Alongside investment to increase availability of syphilis POC tests, operational research is needed to understand how best to improve screening of pregnant women and to translate test availability into improved pregnancy outcomes.
Huddy, Jeremy R; Ni, Melody Z; Markar, Sheraz R; Hanna, George B
2015-01-01
Point-of-care (POC) tests enable rapid results and are well established in medical practice. Recent advances in analytical techniques have led to a new generation of POC devices that will alter gastrointestinal diagnostic pathways. This review aims to identify current and new technologies for the POC diagnosis of gastrointestinal cancer. A structured search of the Embase and Medline databases was performed. Papers reporting diagnostic tests for gastrointestinal cancer available as a POC device or containing a description of feasibility for POC application were included. Studies recovered were heterogeneous and therefore results are presented as a narrative review. Six diagnostic methods were identified (fecal occult blood, fecal proteins, volatile organic compounds, pyruvate kinase isoenzyme type M2, tumour markers and DNA analysis). Fecal occult blood testing has a reported sensitivity of 66%-85% and specificity greater than 95%. The others are at a range of development and clinical application. POC devices have a proven role in the diagnosis of gastrointestinal cancer. Barriers to their implementation exist and the transition from experimental to clinical medicine is currently slow. New technologies demonstrate potential to provide accurate POC tests and an ability to diagnose gastrointestinal cancer at an early stage with improved clinical outcome and survival. PMID:25892860
Huddy, Jeremy R; Ni, Melody Z; Markar, Sheraz R; Hanna, George B
2015-04-14
Point-of-care (POC) tests enable rapid results and are well established in medical practice. Recent advances in analytical techniques have led to a new generation of POC devices that will alter gastrointestinal diagnostic pathways. This review aims to identify current and new technologies for the POC diagnosis of gastrointestinal cancer. A structured search of the Embase and Medline databases was performed. Papers reporting diagnostic tests for gastrointestinal cancer available as a POC device or containing a description of feasibility for POC application were included. Studies recovered were heterogeneous and therefore results are presented as a narrative review. Six diagnostic methods were identified (fecal occult blood, fecal proteins, volatile organic compounds, pyruvate kinase isoenzyme type M2, tumour markers and DNA analysis). Fecal occult blood testing has a reported sensitivity of 66%-85% and specificity greater than 95%. The others are at a range of development and clinical application. POC devices have a proven role in the diagnosis of gastrointestinal cancer. Barriers to their implementation exist and the transition from experimental to clinical medicine is currently slow. New technologies demonstrate potential to provide accurate POC tests and an ability to diagnose gastrointestinal cancer at an early stage with improved clinical outcome and survival.
Quality assurance for HIV point-of-care testing and treatment monitoring assays
Sandstrom, Paul; Denny, Thomas N.; Hurlston, Mackenzie; Ball, Terry B.; Peeling, Rosanna W.; Boeras, Debrah I.
2016-01-01
In 2015, UNAIDS launched the 90-90-90 targets aimed at increasing the number of people infected with HIV to become aware of their status, access antiretroviral therapies and ultimately be virally suppressed. To achieve these goals, countries may need to scale up point-of-care (POC) testing in addition to strengthening central laboratory services. While decentralising testing increases patient access to diagnostics, it presents many challenges with regard to training and assuring the quality of tests and testing. To ensure synergies, the London School of Hygiene & Tropical Medicine held a series of consultations with countries with an interest in quality assurance and their implementing partners, and agreed on an external quality assessment (EQA) programme to ensure reliable results so that the results lead to the best possible care for HIV patients. As a result of the consultations, EQA International was established, bringing together EQA providers and implementers to develop a strategic plan for countries to establish national POC EQA programmes and to estimate the cost of setting up and maintaining the programme. With the dramatic increase in the number of proficiency testing panels required for thousands of POC testing sites across Africa, it is important to facilitate technology transfer from global EQA providers to a network of regional EQA centres in Africa for regional proficiency testing panel production. EQA International will continue to identify robust and cost-effective EQA technologies for quality POC testing, integrating novel technologies to support sustainable country-owned EQA programmes in Africa. PMID:28879133
Exploiting recombinant antibodies in point-of-care (POC) diagnostics: the combinatorial advantage.
Hearty, Stephen; O'Kennedy, Richard
2011-01-01
Antibodies are ubiquitously deployed on in vitro diagnostic (IVD) platforms for detecting a panoply of analytes indicative of environmental and food contamination, residue adulteration and both veterinary and medical diagnostics. In the clinical realm, rapid and accurate determination of disease status is paramount. The significance of immunodiagnostic performance cannot be overemphasized and in many cases reliable diagnosis informs medical intervention which can mean the difference between patient recovery and demise. Cardiovascular disease (CVD) is the single biggest cause of adult mortality in the western world and principal burden on the healthcare services. Although the troponin (Tn) family, in particular troponin I (TnI), are regarded as the gold standard for diagnosis of myocardial damage, over the last decade much research has focused on the identification of alternative cardiac biomarker molecules that can either supplant or complement TnI metrics to add value to cardiac risk stratification criteria. In particular, markers that appear earlier than TnI in the pathophyisiology of cardiac disease are highly sought after. The subject of this addendum represents part of a broader challenge to deliver novel rapid point-of-care (POC) diagnostics to provide a chip-based multi-plexed platform for more comprehensive profiling of cardiac status with additive diagnostic and prognostic value. Specifically, it outlines proof-of-concept direct myeloperoxidase (MPO) detection, demonstrates the benefits of using recombinant antibodies in POC diagnostics and describes optimized strategies for generation of superior candidate antibody panels.
Weir, Nichola-Jane M; Pattison, Sally H; Kearney, Paddy; Stafford, Bob; Gormley, Gerard J; Crockard, Martin A; Gilpin, Deirdre F; Tunney, Michael M; Hughes, Carmel M
2018-01-01
Urinary Tract Infections (UTIs) are common bacterial infections, second only to respiratory tract infections and particularly prevalent within primary care. Conventional detection of UTIs is culture, however, return of results can take between 24 and 72 hours. The introduction of a point of care (POC) test would allow for more timely identification of UTIs, facilitating improved, targeted treatment. This study aimed to obtain consensus on the criteria required for a POC UTI test, to meet patient need within primary care. Criteria for consideration were compiled by the research team. These criteria were validated through a two-round Delphi process, utilising an expert panel of healthcare professionals from across Europe and United States of America. Using web-based questionnaires, panellists recorded their level of agreement with each criterion based on a 5-point Likert Scale, with space for comments. Using median response, interquartile range and comments provided, criteria were accepted/rejected/revised depending on pre-agreed cut-off scores. The first round questionnaire presented thirty-three criteria to the panel, of which 22 were accepted. Consensus was not achieved for the remaining 11 criteria. Following response review, one criterion was removed, while after revision, the remaining 10 criteria entered the second round. Of these, four were subsequently accepted, resulting in 26 criteria considered appropriate for a POC test to detect urinary infections. This study generated an approved set of criteria for a POC test to detect urinary infections. Criteria acceptance and comments provided by the healthcare professionals also supports the development of a multiplex point of care UTI test.
Compounding diagnostic delays: a qualitative study of point-of-care testing in South Africa.
Engel, Nora; Davids, Malika; Blankvoort, Nadine; Pai, Nitika Pant; Dheda, Keertan; Pai, Madhukar
2015-04-01
Successful point-of-care (POC) testing (completion of test-and-treat cycle in one patient encounter) has immense potential to reduce diagnostic and treatment delays, and improve patient and public health outcomes. We explored what tests are done and how in public/private, rural/urban hospitals and clinics in South Africa and whether they can ensure successful POC testing. This qualitative research study examined POC testing across major diseases in Cape Town, Durban and Eastern Cape. We conducted 101 semi-structured interviews and seven focus group discussions with doctors, nurses, community health workers, patients, laboratory technicians, policymakers, hospital managers and diagnostic manufacturers. In South Africa, diagnostics are characterised by a centralised system. Most tests conducted on the spot can be made to work successfully as POC tests. The majority of public/private clinics and smaller hospitals send samples via couriers to centralised laboratories and retrieve results the same way, via internet, fax or phone. The main challenge to POC testing lies in transporting samples and results, while delays risk patient loss from diagnostic/treatment pathways. Strategies to deal with associated delays create new problems, such as artificially prolonged turnaround times, strains on human resources and quality of testing, compounding additional diagnostic and treatment delays. For POC testing to succeed, particular characteristics of diagnostic ecosystems and adaptations of professional practices to overcome associated challenges must be taken into account. © 2014 John Wiley & Sons Ltd.
Weitzel, T; Schnabel, E; Dieckmann, S; Börner, U; Schweiger, B
2007-07-01
Point-of-care (POC) tests for influenza facilitate clinical case management, and might also be helpful in the care of travellers who are at special risk for influenza infection. To evaluate influenza POC testing in travellers, a new assay, the ImmunoCard STAT! Flu A and B, was used to investigate travellers presenting with influenza-like symptoms. Influenza virus infection was diagnosed in 27 (13%) of 203 patients by influenza virus-specific PCR and viral culture. The POC test had sensitivity and specificity values of 64% and 99% for influenza A, and 67% and 100% for influenza B, respectively. Combined sensitivity and specificity were 67% and 99%, respectively, yielding positive and negative predictive values of 95%, and positive and negative likelihood ratios of 117 and 0.34, respectively. The convenient application, excellent specificity and high positive likelihood ratio of the POC test allowed rapid identification of influenza cases. However, negative test results might require confirmation by other methods because of limitations in sensitivity. Overall, influenza POC testing appeared to be a useful tool for the management of travellers with influenza-like symptoms.
Portable devices and mobile instruments for infectious diseases point-of-care testing.
Bissonnette, Luc; Bergeron, Michel G
2017-05-01
Rapidity, simplicity, and portability are highly desirable characteristics of tests and devices designed for performing diagnostics at the point of care (POC), either near patients managed in healthcare facilities or to offer bioanalytical alternatives in external settings. By reducing the turnaround time of the diagnostic cycle, POC diagnostics can reduce the dissemination, morbidity, and mortality of infectious diseases and provide tools to control the global threat of antimicrobial resistance. Areas covered: A literature search of PubMed and Google Scholar, and extensive mining of specialized publications, Internet resources, and manufacturers' websites have been used to organize and write this overview of the challenges and requirements associated with the development of portable sample-to-answer diagnostics, and showcase relevant examples of handheld devices, portable instruments, and less mobile systems which may or could be operated at POC. Expert commentary: Rapid (<1 h) diagnostics can contribute to control infectious diseases and antimicrobial resistant pathogens. Portable devices or instruments enabling sample-to-answer bioanalysis can provide rapid, robust, and reproducible testing at the POC or close from it. Beyond testing, to realize some promises of personalized/precision medicine, it will be critical to connect instruments to healthcare data management systems, to efficiently link decentralized testing results to the electronic medical record of patients.
Kearney, Paddy; Stafford, Bob; Gormley, Gerard J.; Crockard, Martin A.; Gilpin, Deirdre F.
2018-01-01
Background Urinary Tract Infections (UTIs) are common bacterial infections, second only to respiratory tract infections and particularly prevalent within primary care. Conventional detection of UTIs is culture, however, return of results can take between 24 and 72 hours. The introduction of a point of care (POC) test would allow for more timely identification of UTIs, facilitating improved, targeted treatment. This study aimed to obtain consensus on the criteria required for a POC UTI test, to meet patient need within primary care. Methods Criteria for consideration were compiled by the research team. These criteria were validated through a two-round Delphi process, utilising an expert panel of healthcare professionals from across Europe and United States of America. Using web-based questionnaires, panellists recorded their level of agreement with each criterion based on a 5-point Likert Scale, with space for comments. Using median response, interquartile range and comments provided, criteria were accepted/rejected/revised depending on pre-agreed cut-off scores. Results The first round questionnaire presented thirty-three criteria to the panel, of which 22 were accepted. Consensus was not achieved for the remaining 11 criteria. Following response review, one criterion was removed, while after revision, the remaining 10 criteria entered the second round. Of these, four were subsequently accepted, resulting in 26 criteria considered appropriate for a POC test to detect urinary infections. Conclusion This study generated an approved set of criteria for a POC test to detect urinary infections. Criteria acceptance and comments provided by the healthcare professionals also supports the development of a multiplex point of care UTI test. PMID:29879161
Fingerhuth, Stephanie M; Low, Nicola; Bonhoeffer, Sebastian; Althaus, Christian L
2017-07-26
Antibiotic resistance is threatening to make gonorrhoea untreatable. Point-of-care (POC) tests that detect resistance promise individually tailored treatment, but might lead to more treatment and higher levels of resistance. We investigate the impact of POC tests on antibiotic-resistant gonorrhoea. We used data about the prevalence and incidence of gonorrhoea in men who have sex with men (MSM) and heterosexual men and women (HMW) to calibrate a mathematical gonorrhoea transmission model. With this model, we simulated four clinical pathways for the diagnosis and treatment of gonorrhoea: POC test with (POC+R) and without (POC-R) resistance detection, culture and nucleic acid amplification tests (NAATs). We calculated the proportion of resistant infections and cases averted after 5 years, and compared how fast resistant infections spread in the populations. The proportion of resistant infections after 30 years is lowest for POC+R (median MSM: 0.18%, HMW: 0.12%), and increases for culture (MSM: 1.19%, HMW: 0.13%), NAAT (MSM: 100%, HMW: 99.27%), and POC-R (MSM: 100%, HMW: 99.73%). Per 100 000 persons, NAAT leads to 36 366 (median MSM) and 1228 (median HMW) observed cases after 5 years. Compared with NAAT, POC+R averts more cases after 5 years (median MSM: 3353, HMW: 118). POC tests that detect resistance with intermediate sensitivity slow down resistance spread more than NAAT. POC tests with very high sensitivity for the detection of resistance are needed to slow down resistance spread more than by using culture. POC with high sensitivity to detect antibiotic resistance can keep gonorrhoea treatable longer than culture or NAAT. POC tests without reliable resistance detection should not be introduced because they can accelerate the spread of antibiotic-resistant gonorrhoea.
The Point-of-Care Laboratory in Clinical Microbiology
Michel-Lepage, Audrey; Boyer, Sylvie; Raoult, Didier
2016-01-01
SUMMARY Point-of-care (POC) laboratories that deliver rapid diagnoses of infectious diseases were invented to balance the centralization of core laboratories. POC laboratories operate 24 h a day and 7 days a week to provide diagnoses within 2 h, largely based on immunochromatography and real-time PCR tests. In our experience, these tests are conveniently combined into syndrome-based kits that facilitate sampling, including self-sampling and test operations, as POC laboratories can be operated by trained operators who are not necessarily biologists. POC laboratories are a way of easily providing clinical microbiology testing for populations distant from laboratories in developing and developed countries and on ships. Modern Internet connections enable support from core laboratories. The cost-effectiveness of POC laboratories has been established for the rapid diagnosis of tuberculosis and sexually transmitted infections in both developed and developing countries. PMID:27029593
Kaindjee-Tjituka, Francina; Sawadogo, Souleymane; Mutandi, Graham; Maher, Andrew D; Salomo, Natanael; Mbapaha, Claudia; Neo, Marytha; Beukes, Anita; Gweshe, Justice; Muadinohamba, Alexinah; Lowrance, David W
2017-01-01
Access to CD4+ testing remains a common barrier to early initiation of antiretroviral therapy among persons living with HIV/AIDS in low- and middle-income countries. The feasibility of task-shifting of point-of-care (POC) CD4+ testing to lay health workers in Namibia has not been evaluated. From July to August 2011, Pima CD4+ analysers were used to improve access to CD4+ testing at 10 selected public health facilities in Namibia. POC Pima CD4+ testing was performed by nurses or lay health workers. Venous blood samples were collected from 10% of patients and sent to centralised laboratories for CD4+ testing with standard methods. Outcomes for POC Pima CD4+ testing and patient receipt of results were compared between nurses and lay health workers and between the POC method and standard laboratory CD4+ testing methods. Overall, 1429 patients received a Pima CD4+ test; 500 (35.0%) tests were performed by nurses and 929 (65.0%) were performed by lay health workers. When Pima CD4+ testing was performed by a nurse or a lay health worker, 93.2% and 95.2% of results were valid ( p = 0.1); 95.6% and 98.1% of results were received by the patient ( p = 0.007); 96.2% and 94.0% of results were received by the patient on the same day ( p = 0.08). Overall, 97.2% of Pima CD4+ results were received by patients, compared to 55.4% of standard laboratory CD4+ results ( p < 0.001). POC CD4+ testing was feasible and effective when task-shifted to lay health workers. Rollout of POC CD4+ testing via task-shifting can improve access to CD4+ testing and retention in care between HIV diagnosis and antiretroviral therapy initiation in low- and middle-income countries.
Point-of-Care Ultrasound: A Trend in Health Care.
Buerger, Anita M; Clark, Kevin R
2017-11-01
To discuss the current and growing use of point-of-care (POC) ultrasound in the management and care of patients. Several electronic research databases were searched to find articles that emphasized the use of POC ultrasound by health care providers who manage and treat critically ill or injured patients. Thirty-five relevant peer-reviewed journal articles were selected for this literature review. Common themes identified in the literature included the use of POC ultrasound in emergency medicine, military medicine, and remote care; comparison of POC ultrasound to other medical imaging modalities; investigation of the education and training required for nonimaging health care professionals who perform POC ultrasound in their practices; and discussion of the financial implications and limitations of POC ultrasound. POC ultrasound provides clinicians with real-time information to better manage and treat critically ill or injured patients in emergency medicine, military medicine, and remote care. In addition to providing immediate bedside diagnostic information, use of POC ultrasound has increased because of concerns regarding radiation protection. Finally, the expansion of POC ultrasound to other specialty areas requires nonimaging health care professionals to perform bedside ultrasound examinations and interpret the resulting images. Because POC ultrasound is user-dependent, adequate training is essential for all who perform and interpret the examinations. Research involving POC ultrasound will continue as innovations and confidence in ultrasound applications advance. Future research should continue to examine the broad use of POC ultrasound in patient care and management. ©2017 American Society of Radiologic Technologists.
Point-of-Care Diagnostics for Improving Maternal Health in South Africa
Mashamba-Thompson, Tivani P.; Sartorius, Benn; Drain, Paul K.
2016-01-01
Improving maternal health is a global priority, particularly in high HIV-endemic, resource-limited settings. Failure to use health care facilities due to poor access is one of the main causes of maternal deaths in South Africa. “Point-of-care” (POC) diagnostics are an innovative healthcare approach to improve healthcare access and health outcomes in remote and resource-limited settings. In this review, POC testing is defined as a diagnostic test that is carried out near patients and leads to rapid clinical decisions. We review the current and emerging POC diagnostics for maternal health, with a specific focus on the World Health Organization (WHO) quality-ASSURED (Affordability, Sensitivity, Specificity, User friendly, Rapid and robust, Equipment free and Delivered) criteria for an ideal point-of-care test in resource-limited settings. The performance of POC diagnostics, barriers and challenges related to implementing POC diagnostics for maternal health in rural and resource-limited settings are reviewed. Innovative strategies for overcoming these barriers are recommended to achieve substantial progress on improving maternal health outcomes in these settings. PMID:27589808
Bacci, Jennifer L; Klepser, Donald; Tilley, Heather; Smith, Jaclyn K; Klepser, Michael E
2018-01-01
Building collaborative working relationships (CWRs) with physicians or other prescribers is an important step for community pharmacists in establishing a collaborative practice agreement (CPA). This case study describes the individual, context, and exchange factors that drive pharmacist-physician CWR development for community pharmacy-based point-of-care (POC) testing. Two physicians who had entered in a CPA with community pharmacists to provide POC testing were surveyed and interviewed. High scores on the pharmacist-physician collaborative index indicated a high level of collaboration between the physicians and the pharmacist who initiated the relationship. Trust was established through the physicians' personal relationships with the pharmacist or due to the community pharmacy organization's strong reputation. The physicians' individual perceptions of community pharmacy-based POC testing affected their CWRs and willingness to establish a CPA. These findings suggest that exchange characteristics remain significant factors in CWR development. Individual factors may also contribute to physicians' willingness to advance their CWR to include a CPA for POC testing. Copyright © 2017 Elsevier Inc. All rights reserved.
Cost-effectiveness analysis of early point-of-care lactate testing in the emergency department.
Ward, Michael J; Self, Wesley H; Singer, Adam; Lazar, Danielle; Pines, Jesse M
2016-12-01
To determine the cost-effectiveness of implementing a point-of-care (POC) Lactate Program in the emergency department (ED) for patients with suspected sepsis to identify patients who can benefit from early resuscitation. We constructed a cost-effectiveness model to examine an ED with 30 000 patients annually. We evaluated a POC lactate program screening patients with suspected sepsis for an elevated lactate ≥4 mmol/L. Those with elevated lactate levels are resuscitated and their lactate clearance is evaluated by serial POC lactate measurements. The POC Lactate Program was compared with a Usual Care Strategy in which all patients with sepsis and an elevated lactate are admitted to the intensive care unit. Costs were estimated from the 2014 Medicare Inpatient and National Physician Fee schedules, and hospital and industry estimates. In the base-case, the POC Lactate Program cost $39.53/patient whereas the Usual Care Strategy cost $33.20/patient. The screened patients in the POC arm resulted in 1.07 quality-adjusted life years for an incremental cost-effectiveness ratio of $31 590 per quality-adjusted life year gained, well below accepted willingness-to-pay-thresholds. Implementing a POC Lactate Program for screening ED patients with suspected sepsis is a cost-effective intervention to identify patients responsive to early resuscitation. Copyright © 2016 Elsevier Inc. All rights reserved.
Louie, Richard F; Ferguson, William J; Curtis, Corbin M; Vy, John H; Kost, Gerald J
2014-03-01
Strategic integration of point-of-care (POC) diagnostic tools during crisis response can accelerate triage and improve management of victims. Timely differential diagnosis is essential wherever care is provided to rule out or rule in disease, expedite life-saving treatment, and improve utilization of limited resources. POC testing needs to be accurate in any environment in which it is used. Devices are exposed to potentially adverse storage and operating conditions, such as high/low temperature and humidity during emergencies and field rescues. Therefore, characterizing environmental conditions allows technology developers, operators, and responders to understand the broad operational requirements of test reagents, instruments, and equipment in order to improve the quality and delivery of care in complex emergencies, disasters, and austere environmental settings. This review aims to describe the effects of environmental stress on POC testing performance and its impact on decision-making, to describe how to study the effects, and to summarize ways to mitigate the effects of environmental stresses through good laboratory practice, development of robust reagents, and novel thermal packaging solutions.
Evidence-Based Point-of-Care Diagnostics: Current Status and Emerging Technologies
NASA Astrophysics Data System (ADS)
Chan, Cangel Pui Yee; Mak, Wing Cheung; Cheung, Kwan Yee; Sin, King Keung; Yu, Cheuk Man; Rainer, Timothy H.; Renneberg, Reinhard
2013-06-01
Point-of-care (POC) diagnostics brings tests nearer to the site of patient care. The turnaround time is short, and minimal manual interference enables quick clinical management decisions. Growth in POC diagnostics is being continuously fueled by the global burden of cardiovascular and infectious diseases. Early diagnosis and rapid initiation of treatment are crucial in the management of such patients. This review provides the rationale for the use of POC tests in acute coronary syndrome, heart failure, human immunodeficiency virus, and tuberculosis. We also consider emerging technologies that are based on advanced nanomaterials and microfluidics, improved assay sensitivity, miniaturization in device design, reduced costs, and high-throughput multiplex detection, all of which may shape the future development of POC diagnostics.
Natoli, L; Guy, R J; Shephard, M; Whiley, D; Tabrizi, S N; Ward, J; Regan, D G; Badman, S G; Anderson, D A; Kaldor, J; Maher, L
2015-04-28
With accurate molecular tests now available for diagnosis of chlamydia and gonorrhoea (Chlamydia trachomatis (CT)/Neisseria gonorrhoeae (NG)) at the point-of-care (POC), we aimed to explore the public health implications (benefits and barriers) of their integration into remote primary care in Australia. Qualitative interviews were conducted with a purposively selected group of 18 key informants reflecting sexual health, primary care, remote Aboriginal health and laboratory expertise. Participants believed that POC testing may decrease community prevalence of sexually transmitted infections (STIs), and associated morbidity by reducing the time to treatment and infectious period and expediting partner notification. Also, POC testing could improve acceptability of STI testing, increase testing coverage and result in more targeted prescribing, thereby minimising the risk of antibiotic resistance. Conversely, some felt the immediacy of diagnosis could deter certain young people from being tested. Participants also noted that POC testing may reduce the completeness of communicable disease surveillance data given the current dependence on reporting from pathology laboratories. Others expressed concern about the need to maintain and improve the flow of NG antibiotic sensitivity data, already compromised by the shift to nucleic acid-based testing. This is particularly relevant to remote areas where culture viability is problematic. Results indicate a high level of support from clinicians and public health practitioners for wider access to CT/NG POC tests citing potential benefits, including earlier, more accurate treatment decisions and reductions in ongoing transmission. However, the data also highlight the need for new systems to avoid adverse impact on disease surveillance. Australian and New Zealand Clinical Trials Registry: ACTRN12613000808741. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to
Microfluidic point-of-care diagnostics for resource-poor environments
NASA Astrophysics Data System (ADS)
Laksanasopin, Tassaneewan; Chin, Curtis D.; Moore, Hannah; Wang, Jennifer; Cheung, Yuk Kee; Sia, Samuel K.
2009-05-01
Point-of-care (POC) diagnostics have tremendous potential to improve human health in remote and resource-poor settings. However, the design criteria for diagnostic tests appropriate in settings with limited infrastructure are unique and challenging. Here we present a custom optical reader which quantifies silver absorbance from heterogeneous immunoassays. The reader is simple and low-cost and suited for POC diagnostics.
Griffey, Richard T; Trent, Caleb J; Bavolek, Rebecca A; Keeperman, Jacob B; Sampson, Christopher; Poirier, Robert F
2013-01-01
Failure to detect pregnancy in the emergency department (ED) can have important consequences. Urine human chorionic gonadotropin (uhCG) point-of-care (POC) assays are valued for rapidly detecting early pregnancy with high sensitivity. However, under certain conditions, POC uhCG tests can fail to detect pregnancy. In investigating a series of late first-trimester false-negative pregnancy tests in our ED, a novel and distinct causative phenomenon was recently elucidated in our institution. We discuss uhCG POC tests, review our false-negative rate, and describe mechanisms for false negatives and potential remedies. The false-negative POC uhCG rate is very low, but in the setting of a large volume of tests, the numbers are worth consideration. In positive uhCG POC tests, free and fixed antibodies bind hCG to form a "sandwich"; hCG is present in several variant forms that change in their concentrations at different stages of pregnancy. When in excess, intact hCG can saturate the antibodies, preventing sandwich formation (hook effect phenomenon). Some assays may include an antibody that does not recognize certain variants present in later stages of pregnancy. When this variant is in excess, it can bind one antibody avidly and the other not at all, resulting in a false-negative test (hook-like phenomenon). In both situations, dilution is key to an accurate test. Manufacturers should consider that uhCG tests are routinely used at many stages of pregnancy. Characterizing uhCG variants recognized by their tests and eliminating lot-to-lot variability may help improve uhCG test performance. Clinicians need to be aware of and familiarize themselves with the limitations of the specific type of uhCG POC tests used in their practice, recognizing that under certain circumstances, false-negative tests can occur. Copyright © 2013 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Lee, Stephen R.; Kardos, Keith W.; Yearwood, Graham D.; Guillon, Geraldine B.; Kurtz, Lisa A.; Mokkapati, Vijaya K.
2008-04-01
Rapid, point of care (POC) testing has been increasingly deployed as an aid in the diagnosis of infectious disease, due to its ability to deliver rapid, actionable results. In the case of HIV, a number of rapid test devices have been FDA approved and CLIA-waived in order to enable diagnosis of HIV infection outside of traditional laboratory settings. These settings include STD clinics, community outreach centers and mobile testing units, as well as identifying HIV infection among pregnant women and managing occupational exposure to infection. The OraQuick ® rapid test platform has been widely used to identify HIV in POC settings, due to its simplicity, ease of use and the ability to utilize oral fluid as an alternative specimen to blood. More recently, a rapid test for antibodies to hepatitis C virus (HCV) has been developed on the same test platform which uses serum, plasma, finger-stick blood, venous blood and oral fluid. Clinical testing using this POC test device has shown that performance is equivalent to state of the art, laboratory based tests. These devices may be suitable for rapid field testing of blood and other body fluids for the presence of infectious agents.
Begeman, Ian J; Lykins, Joseph; Zhou, Ying; Lai, Bo Shiun; Levigne, Pauline; El Bissati, Kamal; Boyer, Kenneth; Withers, Shawn; Clouser, Fatima; Noble, A Gwendolyn; Rabiah, Peter; Swisher, Charles N; Heydemann, Peter T; Contopoulos-Ioannidis, Despina G; Montoya, Jose G; Maldonado, Yvonne; Ramirez, Raymund; Press, Cindy; Stillwaggon, Eileen; Peyron, François; McLeod, Rima
2017-06-01
Congenital toxoplasmosis is a serious but preventable and treatable disease. Gestational screening facilitates early detection and treatment of primary acquisition. Thus, fetal infection can be promptly diagnosed and treated and outcomes can be improved. We tested 180 sera with the Toxoplasma ICT IgG-IgM point-of-care (POC) test. Sera were from 116 chronically infected persons (48 serotype II; 14 serotype I-III; 25 serotype I-IIIa; 28 serotype Atypical, haplogroup 12; 1 not typed). These represent strains of parasites infecting mothers of congenitally infected children in the U.S. 51 seronegative samples and 13 samples from recently infected persons known to be IgG/IgM positive within the prior 2.7 months also were tested. Interpretation was confirmed by two blinded observers. A comparison of costs for POC vs. commercial laboratory testing methods was performed. We found that this new Toxoplasma ICT IgG-IgM POC test was highly sensitive (100%) and specific (100%) for distinguishing IgG/IgM-positive from negative sera. Use of such reliable POC tests can be cost-saving and benefit patients. Our work demonstrates that the Toxoplasma ICT IgG-IgM test can function reliably as a point-of-care test to diagnose Toxoplasma gondii infection in the U.S. This provides an opportunity to improve maternal-fetal care by using approaches, diagnostic tools, and medicines already available. This infection has serious, lifelong consequences for infected persons and their families. From the present study, it appears a simple, low-cost POC test is now available to help prevent morbidity/disability, decrease cost, and make gestational screening feasible. It also offers new options for improved prenatal care in low- and middle-income countries.
Zhou, Ying; Lai, Bo Shiun; Levigne, Pauline; El Bissati, Kamal; Boyer, Kenneth; Withers, Shawn; Clouser, Fatima; Noble, A. Gwendolyn; Rabiah, Peter; Swisher, Charles N.; Heydemann, Peter T.; Contopoulos-Ioannidis, Despina G.; Montoya, Jose G.; Maldonado, Yvonne; Ramirez, Raymund; Press, Cindy; Stillwaggon, Eileen; Peyron, François
2017-01-01
Background Congenital toxoplasmosis is a serious but preventable and treatable disease. Gestational screening facilitates early detection and treatment of primary acquisition. Thus, fetal infection can be promptly diagnosed and treated and outcomes can be improved. Methods We tested 180 sera with the Toxoplasma ICT IgG-IgM point-of-care (POC) test. Sera were from 116 chronically infected persons (48 serotype II; 14 serotype I-III; 25 serotype I-IIIa; 28 serotype Atypical, haplogroup 12; 1 not typed). These represent strains of parasites infecting mothers of congenitally infected children in the U.S. 51 seronegative samples and 13 samples from recently infected persons known to be IgG/IgM positive within the prior 2.7 months also were tested. Interpretation was confirmed by two blinded observers. A comparison of costs for POC vs. commercial laboratory testing methods was performed. Results We found that this new Toxoplasma ICT IgG-IgM POC test was highly sensitive (100%) and specific (100%) for distinguishing IgG/IgM-positive from negative sera. Use of such reliable POC tests can be cost-saving and benefit patients. Conclusions Our work demonstrates that the Toxoplasma ICT IgG-IgM test can function reliably as a point-of-care test to diagnose Toxoplasma gondii infection in the U.S. This provides an opportunity to improve maternal-fetal care by using approaches, diagnostic tools, and medicines already available. This infection has serious, lifelong consequences for infected persons and their families. From the present study, it appears a simple, low-cost POC test is now available to help prevent morbidity/disability, decrease cost, and make gestational screening feasible. It also offers new options for improved prenatal care in low- and middle-income countries. PMID:28650970
Gish, R G; Gutierrez, J A; Navarro-Cazarez, N; Giang, K; Adler, D; Tran, B; Locarnini, S; Hammond, R; Bowden, S
2014-12-01
Early identification of chronic hepatitis B is important for optimal disease management and prevention of transmission. Cost and lack of access to commercial hepatitis B surface antigen (HBsAg) immunoassays can compromise the effectiveness of HBV screening in resource-limited settings and among marginalized populations. High-quality point-of-care (POC) testing may improve HBV diagnosis in these situations. Currently available POC HBsAg assays are often limited in sensitivity. We evaluated the NanoSign(®) HBs POC chromatographic immunoassay for its ability to detect HBsAg of different genotypes and with substitutions in the 'a' determinant. Thirty-seven serum samples from patients with HBV infection, covering HBV genotypes A-G, were assessed for HBsAg titre with the Roche Elecsys HBsAg II quantification assay and with the POC assay. The POC assay reliably detected HBsAg at a concentration of at least 50 IU/mL for all genotypes, and at lower concentrations for some genotypes. Eight samples with substitutions in the HBV 'a' determinant were reliably detected after a 1/100 dilution. The POC strips were used to screen serum samples from 297 individuals at risk for HBV in local clinical settings (health fairs and outreach events) in parallel with commercial laboratory HBsAg testing (Quest Diagnostics EIA). POC testing was 73.7% sensitive and 97.8% specific for detection of HBsAg. Although the POC test demonstrated high sensitivity over a range of genotypes, false negatives were frequent in a clinical setting. Nevertheless, the POC assay offers advantages for testing in both developed and resource-limited countries due to its low cost (0.50$) and immediately available results. © 2014 John Wiley & Sons Ltd.
Gerald, J Kost; William, J Ferguson; Laurie, E Kost
2014-09-01
This article a) defines point of care (POC) culture; b) presents seven underlying fundamental principles; c) describes the importance of needs assessment; d) introduces a new innovation, the spatial care path™; and e) illustrates how POC testing that properly fulfills needs and spatial care paths™ enable community and global resilience. Often, POC testing supplants the conventional clinical laboratory, which may be too distant, prohibitively expensive, or simply not available in limited-resource settings. New POC technologies "fit" future medical problem solving. Screening and testing directly in the home or primary care facilitate rapid diagnosis, monitoring, and treatment. In contrast to the past where attention has been placed on emergency departments, hospitals, and referral centers, the spatial care path™ starts with the patient and guides him or her through an efficient strategy of care in small-world networks (SWNs) defined by local geography and topology, long-standing customs, public health jurisdictions, and geographic information systems (GIS). POC testing needs in limited-resource settings are striking. Fulfillment is best guided by thorough understanding of POC culture. Quick feedback and fast decision-making by patients and physicians alike yield significant value that motivates changes in patient lifestyles and physician interactions. Culturally sensitive technology assimilation addresses leadership challenges in nations adapting to increasing populations of young and old, despite scarcity of resources. The spatial care path™ facilitates an essential balance of prevention and intervention in public health and shifts future focus to the patient, empowerment, and primary care within the context of POC culture.
Turner, Katherine M E; Round, Jeff; Horner, Patrick; Macleod, John; Goldenberg, Simon; Deol, Arminder; Adams, Elisabeth J
2014-03-01
To estimate the costs and benefits of clinical pathways incorporating a point of care (POC) nucleic acid amplification test (NAAT) for chlamydia and gonorrhoea in genitourinary medicine (GUM) clinics compared with standard off-site laboratory testing. We simulated 1.2 million GUM clinic attendees in England. A simulation in Microsoft Excel was developed to compare existing standard pathways of management for chlamydia and gonorrhoea with a POC NAAT. We conducted scenario analyses to evaluate the robustness of the model findings. The primary outcome was the incremental cost-effectiveness ratio. Secondary outcomes included the number of inappropriate treatments, complications and transmissions averted. The baseline cost of using the point of POC NAAT was £103.9 million compared with £115.6 million for standard care. The POC NAAT was also associated with a small increase of 46 quality adjusted life years, making the new test both more effective and cheaper. Over 95 000 inappropriate treatments might be avoided by using a POC NAAT. Patients receive diagnosis and treatment on the same day as testing, which may also prevent 189 cases of pelvic inflammatory disease and 17 561 onward transmissions annually. Replacing standard laboratory tests for chlamydia and gonorrhoea with a POC test could be cost saving and patients would benefit from more accurate diagnosis and less unnecessary treatment. Overtreatment currently accounts for about a tenth of the reported treatments for chlamydia and gonorrhoea and POC NAATs would effectively eliminate the need for presumptive treatment.
Miniaturized technology for protein and nucleic acid point-of-care testing.
Olasagasti, Felix; Ruiz de Gordoa, Juan Carlos
2012-11-01
The field of point-of-care (POC) testing technology is developing quickly and producing instruments that are increasingly reliable, while their size is being gradually reduced. Proteins are a common target for POC analyses and the detection of protein markers typically involves immunoassays aimed at detecting different groups of proteins such as tumor markers, inflammation proteins, and cardiac markers; but other techniques can also be used to analyze plasma proteins. In the case of nucleic acids, hybridization and amplification strategies can be used to record electromagnetic or electric signals. These techniques allow for the identification of specific viral or bacterial infections as well as specific cancers. In this review, we consider some of the latest advances in the analysis of specific nucleic acid and protein biomarkers, taking into account their trend toward miniaturization and paying special attention to the technology that can be implemented in future applications, such as lab-on-a-chip instruments. Copyright © 2012 Mosby, Inc. All rights reserved.
Fei, Yang; Wang, Wei; He, Falin; Zhong, Kun; Wang, Zhiguo
2015-10-01
The aim of this study was to use Six Sigma(SM) (Motorola Trademark Holdings, Libertyville, IL) techniques to analyze the quality of point-of-care (POC) glucose testing measurements quantitatively and to provide suggestions for improvement. In total, 151 laboratories in China were included in this investigation in 2014. Bias and coefficient of variation were collected from an external quality assessment and an internal quality control program, respectively, for POC glucose testing organized by the National Center for Clinical Laboratories. The σ values and the Quality Goal Index were used to evaluate the performance of POC glucose meters. There were 27, 30, 57, and 37 participants in the groups using Optium Xceed™ (Abbott Diabetes Care, Alameda, CA), Accu-Chek(®) Performa (Roche, Basel, Switzerland), One Touch Ultra(®) (Abbott), and "other" meters, respectively. The median of the absolute value of percentage difference varied among different lots and different groups. Among all the groups, the Abbott One Touch Ultra group had the smallest median of absolute value of percentage difference except for lot 201411, whereas the "other" group had the largest median in all five lots. More than 85% of participate laboratories satisfied the total allowable error (TEa) requirement in International Organization for Standardization standard 15197:2013, and 85.43% (129/151) of laboratories obtained intralaboratory coefficient of variations less than 1/3TEa. However, Six Sigma techniques suggested that 41.72% (63/151) to 65.56% (99/151) of the laboratories needed to improve their POC glucose testing performance, in either precision, trueness, or both. Laboratories should pay more attention on the practice of POC glucose testing and take actions to improve their performance. Only in this way can POC glucose testing really function well in clinical practice.
Adams, Elisabeth J; Ehrlich, Alice; Turner, Katherine M E; Shah, Kunj; Macleod, John; Goldenberg, Simon; Meray, Robin K; Pearce, Vikki; Horner, Patrick
2014-07-23
We aimed to explore patient pathways using a chlamydia/gonorrhoea point-of-care (POC) nucleic acid amplification test (NAAT), and estimate and compare the costs of the proposed POC pathways with the current pathways using standard laboratory-based NAAT testing. Workshops were conducted with healthcare professionals at four sexual health clinics representing diverse models of care in the UK. They mapped out current pathways that used chlamydia/gonorrhoea tests, and constructed new pathways using a POC NAAT. Healthcare professionals' time was assessed in each pathway. The proposed POC pathways were then priced using a model built in Microsoft Excel, and compared to previously published costs for pathways using standard NAAT-based testing in an off-site laboratory. Pathways using a POC NAAT for asymptomatic and symptomatic patients and chlamydia/gonorrhoea-only tests were shorter and less expensive than most of the current pathways. Notably, we estimate that POC testing as part of a sexual health screen for symptomatic patients, or as stand-alone chlamydia/gonorrhoea testing, could reduce costs per patient by as much as £16 or £6, respectively. In both cases, healthcare professionals' time would be reduced by approximately 10 min per patient. POC testing for chlamydia/gonorrhoea in a clinical setting may reduce costs and clinician time, and may lead to more appropriate and quicker care for patients. Further study is warranted on how to best implement POC testing in clinics, and on the broader clinical and cost implications of this technology. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.
Surface enhanced Raman spectroscopy (SERS) for in vitro diagnostic testing at the point of care
NASA Astrophysics Data System (ADS)
Marks, Haley; Schechinger, Monika; Garza, Javier; Locke, Andrea; Coté, Gerard
2017-06-01
Point-of-care (POC) device development is a growing field that aims to develop low-cost, rapid, sensitive in-vitro diagnostic testing platforms that are portable, self-contained, and can be used anywhere - from modern clinics to remote and low resource areas. In this review, surface enhanced Raman spectroscopy (SERS) is discussed as a solution to facilitating the translation of bioanalytical sensing to the POC. The potential for SERS to meet the widely accepted "ASSURED" (Affordable, Sensitive, Specific, User-friendly, Rapid, Equipment-free, and Deliverable) criterion provided by the World Health Organization is discussed based on recent advances in SERS in vitro assay development. As SERS provides attractive characteristics for multiplexed sensing at low concentration limits with a high degree of specificity, it holds great promise for enhancing current efforts in rapid diagnostic testing. In outlining the progression of SERS techniques over the past years combined with recent developments in smart nanomaterials, high-throughput microfluidics, and low-cost paper diagnostics, an extensive number of new possibilities show potential for translating SERS biosensors to the POC.
Gubbins, Paul O; Klepser, Michael E; Adams, Alex J; Jacobs, David M; Percival, Kelly M; Tallman, Gregory B
Health care professionals must continually identify collaborative ways to combat antibiotic resistance while improving community health and health care delivery. Clinical Laboratory Improvement Amendments of 1988 (CLIA)-waived point-of-care (POC) testing (POCT) services for infectious disease conducted in community pharmacies provide a means for pharmacists to collaborate with prescribers and/or public health officials combating antibiotic resistance while improving community health and health care delivery. To provide a comprehensive literature review that explores the potential for pharmacists to collaborate with public health professionals and prescribers using pharmacy-based CLIA-waived POCT services for infectious diseases. Comprehensive literature review. PubMed and Google Scholar were searched for manuscripts and meeting abstracts for the following key words: infectious disease, community pharmacy, rapid diagnostic tests, rapid assay, and POC tests. All relevant manuscripts and meeting abstracts utilizing POCT in community pharmacies for infectious disease were reviewed. Information regarding the most contemporary evidence regarding CLIA-waived POC infectious diseases tests for infectious diseases and their use in community pharmacies was synthesized to highlight and identify opportunities to develop future collaborations using community pharmacy-based models for such services. Evidence demonstrates that pharmacists in collaboration with other health care professionals can leverage their knowledge and accessibility to provide CLIA-waived POCT services for infectious diseases. Testing for influenza may augment health departments' surveillance efforts, help promote rationale antiviral use, and avoid unnecessary antimicrobial therapy. Services for human immunodeficiency virus infection raise infection status awareness, increase access to health care, and facilitate linkage to appropriate care. Testing for group A streptococcal pharyngitis may curb inappropriate
Cohen-Bacrie, Stéphan; Ninove, Laetitia; Nougairède, Antoine; Charrel, Rémi; Richet, Hervé; Minodier, Philippe; Badiaga, Sékéné; Noël, Guilhem; La Scola, Bernard; de Lamballerie, Xavier; Drancourt, Michel; Raoult, Didier
2011-01-01
Clinical microbiology may direct decisions regarding hospitalization, isolation and anti-infective therapy, but it is not effective at the time of early care. Point-of-care (POC) tests have been developed for this purpose. One pilot POC-lab was located close to the core laboratory and emergency ward to test the proof of concept. A second POC-lab was located inside the emergency ward of a distant hospital without a microbiology laboratory. Twenty-three molecular and immuno-detection tests, which were technically undemanding, were progressively implemented, with results obtained in less than four hours. From 2008 to 2010, 51,179 tests yielded 6,244 diagnoses. The second POC-lab detected contagious pathogens in 982 patients who benefited from targeted isolation measures, including those undertaken during the influenza outbreak. POC tests prevented unnecessary treatment of patients with non-streptococcal tonsillitis (n = 1,844) and pregnant women negative for Streptococcus agalactiae carriage (n = 763). The cerebrospinal fluid culture remained sterile in 50% of the 49 patients with bacterial meningitis, therefore antibiotic treatment was guided by the molecular tests performed in the POC-labs. With regard to enterovirus meningitis, the mean length-of-stay of infected patients over 15 years old significantly decreased from 2008 to 2010 compared with 2005 when the POC was not in place (1.43±1.09 versus 2.91±2.31 days; p = 0.0009). Altogether, patients who received POC tests were immediately discharged nearly thrice as often as patients who underwent a conventional diagnostic procedure. The on-site POC-lab met physicians' needs and influenced the management of 8% of the patients that presented to emergency wards. This strategy might represent a major evolution of decision-making regarding the management of infectious diseases and patient care.
Cohen-Bacrie, Stéphan; Ninove, Laetitia; Nougairède, Antoine; Charrel, Rémi; Richet, Hervé; Minodier, Philippe; Badiaga, Sékéné; Noël, Guilhem; La Scola, Bernard; de Lamballerie, Xavier; Drancourt, Michel; Raoult, Didier
2011-01-01
Background Clinical microbiology may direct decisions regarding hospitalization, isolation and anti-infective therapy, but it is not effective at the time of early care. Point-of-care (POC) tests have been developed for this purpose. Methods and Findings One pilot POC-lab was located close to the core laboratory and emergency ward to test the proof of concept. A second POC-lab was located inside the emergency ward of a distant hospital without a microbiology laboratory. Twenty-three molecular and immuno-detection tests, which were technically undemanding, were progressively implemented, with results obtained in less than four hours. From 2008 to 2010, 51,179 tests yielded 6,244 diagnoses. The second POC-lab detected contagious pathogens in 982 patients who benefited from targeted isolation measures, including those undertaken during the influenza outbreak. POC tests prevented unnecessary treatment of patients with non-streptococcal tonsillitis (n = 1,844) and pregnant women negative for Streptococcus agalactiae carriage (n = 763). The cerebrospinal fluid culture remained sterile in 50% of the 49 patients with bacterial meningitis, therefore antibiotic treatment was guided by the molecular tests performed in the POC-labs. With regard to enterovirus meningitis, the mean length-of-stay of infected patients over 15 years old significantly decreased from 2008 to 2010 compared with 2005 when the POC was not in place (1.43±1.09 versus 2.91±2.31 days; p = 0.0009). Altogether, patients who received POC tests were immediately discharged nearly thrice as often as patients who underwent a conventional diagnostic procedure. Conclusions The on-site POC-lab met physicians' needs and influenced the management of 8% of the patients that presented to emergency wards. This strategy might represent a major evolution of decision-making regarding the management of infectious diseases and patient care. PMID:21811599
Point-of-Care Coagulation Monitoring in Trauma Patients.
Stein, Philipp; Kaserer, Alexander; Spahn, Gabriela H; Spahn, Donat R
2017-06-01
Trauma remains one of the major causes of death and disability all over the world. Uncontrolled blood loss and trauma-induced coagulopathy represent preventable causes of trauma-related morbidity and mortality. Treatment may consist of allogeneic blood product transfusion at a fixed ratio or in an individualized goal-directed way based on point-of-care (POC) and routine laboratory measurements. Viscoelastic POC measurement of the developing clot in whole blood and POC platelet function testing allow rapid and tailored coagulation and transfusion treatment based on goal-directed, factor concentrate-based algorithms. The first studies have been published showing that this concept reduces the need for allogeneic blood transfusion and improves outcome. This review highlights the concept of goal-directed POC coagulation management in trauma patients, introduces a selection of POC devices, and presents algorithms which allow a reduction in allogeneic blood product transfusion and an improvement of trauma patient outcome. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.
Hex, Chiel; Smeets, Miek; Penders, Joris; Van Hoof, Viviane; Verbakel, Jan; Buntinx, Frank; Vaes, Bert
2018-06-01
N-terminal pro-B-type natriuretic peptide (NT-proBNP) has been shown to be useful for ruling out heart failure in primary care. In this study, we examined the accuracy of the Cobas h232 point-of-care (POC) instrument in primary care compared with an in-hospital measurement. Furthermore, we investigated the user-friendliness and usefulness of the POC device. Five general practitioner (GP) groups were asked to evaluate adult patients who were suspected of having heart failure and to test NT-proBNP with the Cobas h232. The samples were subsequently delivered to and analysed at a central hospital laboratory by the Cobas e602 using conventional transport and storage. Difference between the paired measurements was analysed using a percentage difference plot, and correlation was assessed using Passing-Bablok linear regression analysis. User-friendliness and usefulness were assessed using semistructured questionnaires. Nineteen GPs studied 94 patients. Passing-Bablok analysis showed a slope of 1.05 (95% CI 1.00 to 1.11) (R 2 =0.97). The percentage difference plot showed a mean difference of 15.7% (95% CI -46.0% to -77.4%). User-friendliness and usefulness had median scores of 4 or 5 on a five-point Likert scale. Eighteen out of 19 GPs confirmed that the device influenced their clinical practice. During the study, GPs' confidence in using NT-proBNP increased significantly from a mean score of 4.4 (95% CI 3.2 to 5.6) to 7.6 out of 10 (95% CI 7.1 to 8.2). The Cobas h232 NT-proBNP POC test proved to be an accurate, user-friendly and useful test in primary care. Nearly all participating GPs were convinced that the test could benefit clinical decision making. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
Madhivanan, Purnima; Krupp, Karl; Hardin, Jill; Karat, Chitra; Klausner, Jeffrey D; Reingold, Arthur L
2009-06-01
Bacterial vaginosis (BV) and Trichomonas vaginalis infection (TV) have been associated with adverse birth outcomes and increased risk for HIV. We compare the performance of simple inexpensive point-of-care (POC) tests to laboratory diagnosis and syndromic management of BV and TV in poor settings. Between November 2005 and March 2006, 898 sexually active women attending two reproductive health clinics in Mysore, India were recruited into a cohort study investigating the relationship between vaginal flora and HSV-2 infection. Participants were interviewed and screened for reproductive tract infections. Laboratory tests included serology for HSV-2; cultures for TV, Candida sp., and Neisseria gonorrhoeae; Gram stains; and two POC tests: vaginal pH; and Whiff test. Of the 898 participants, 411 [45.7%, 95% confidence interval (95% CI): 42.4-49.0%] had any laboratory diagnosed vaginal infection. BV was detected in 165 women (19.1%, 95%CI: 16.5-21.9%) using Nugent score. TV was detected in 76 women (8.5%, 95%CI: 6.7-10.4%) using culture. Among the entire study population, POC correctly detected 82% of laboratory diagnosed BV cases, and 83% of laboratory diagnosed TV infections. Among women with complaints of vulval itching, burning, abnormal vaginal discharge, and/or sores (445/898), POC correctly detected 83% (60 of 72 cases) of laboratory diagnosed BV cases vs. 40% (29 of 72 cases) correctly managed using the syndromic approach (P < 0.001). Similarly, POC would have detected 82% (37 of 45 cases) of TV cases vs. 51% (23 of 45 cases) correctly managed using the syndromic approach (P = 0.001). In the absence of laboratory diagnostics, POC is not only inexpensive and practical, but also significantly more sensitive than the syndromic management approach, resulting in less overtreatment. .
Page-Shipp, Liesl; Lewis, James J; Velen, Kavindhran; Senoge, Sedikanelo; Zishiri, Elizabeth; Popane, Flora; Chihota, Violet N; Clark, Dave; Churchyard, Gavin J; Charalambous, Salome
2018-01-01
In South Africa, TB household contact tracing provides an opportunity for increased TB and HIV case finding. We aimed to determine the effect of two new potential interventions for TB contact tracing programmes: Point of Care CD4 (PoC CD4) on HIV linkage to care and household Isoniazid Preventive Therapy (IPT) provision on uptake and retention of IPT. A pragmatic, three-arm, cluster-randomized trial was undertaken. TB Household contacts were randomised to 3 arms: 1) Standard of Care TB and HIV testing (SOC); 2) SOC with POC CD4 for those testing HIV positive; 3) SOC with POC CD4 and IPT for eligible household members. Linkage to care within 90 days was assessed either through patient visits (at 10 weeks and 6 months) or via telephonic contact. 2,243 index TB patients and 3,012 contacts (64,3% female, median age 30 years) were enrolled. On self-report, 26(1.2%) were currently receiving TB treatment and 1816 (60.3%) reported a prior HIV test. HIV testing uptake was 34.7% in the SoC arm, 40.2% in the PoC CD4 arm (RR1.16, CI 0.99-1.36, p-value = 0.060) and 39.9% in the PoC CD4 + HH-IPT arm (RR = 1.15, CI 0.99-1.35, p-value = 0.075). Linkage to care within 3 months was 30.8% in the SoC arm and 42.1% in the POC CD4 arms (RR 1.37; CI: 0.68-2.76, p-value = 0.382). 20/21 contacts (95.2%) initiated IPT in the PoC CD4 + HH-IPT arm, compared to 3/20 (15.0%) in the PoC CD4 arm (p = 0.004; p-value from Fisher's exact test < 0.001). Among 3,008 contacts screened for tuberculosis, 15 (3.4%) had bacteriologically confirmed TB with an overall yield of TB of 0.5% (95% CI: 0.3%, 0.8%). Household PoC CD4 testing and IPT initiation is feasible. There was only weak evidence that PoCCD4 led to a small increase in HCT uptake and no evidence for an increase in linkage-to-care. IPT initiation and completion was increased by the household intervention. Although feasible, these interventions had low impact due to the low uptake of HIV testing in households.
Point-of-Care Hemoglobin A1c Testing: An Evidence-Based Analysis
2014-01-01
Background The increasing prevalence of diabetes in Ontario means that there will be growing demand for hemoglobin A1c (HbA1c) testing to monitor glycemic control for the management of this chronic disease. Testing HbA1c where patients receive their diabetes care may improve system efficiency if the results from point-of-care HbA1c testing are comparable to those from laboratory HbA1c measurements. Objectives To review the correlation between point-of-care HbA1c testing and laboratory HbA1c measurement in patients with diabetes in clinical settings. Data Sources The literature search included studies published between January 2003 and June 2013. Search terms included glycohemoglobin, hemoglobin A1c, point of care, and diabetes. Review Methods Studies were included if participants had diabetes; if they compared point-of-care HbA1c devices (licensed by Health Canada and available in Canada) with laboratory HbA1c measurement (reference method); if they performed point-of-care HbA1c testing using capillary blood samples (finger pricks) and laboratory HbA1c measurement using venous blood samples within 7 days; and if they reported a correlation coefficient between point-of-care HbA1c and laboratory HbA1c results. Results Three point-of-care HbA1c devices were reviewed in this analysis: Bayer's A1cNow+, Bio-Rad's In2it, and Siemens’ DCA Vantage. Five observational studies met the inclusion criteria. The pooled results showed a positive correlation between point-of-care HbA1c testing and laboratory HbA1c measurement (correlation coefficient, 0.967; 95% confidence interval, 0.960–0.973). Limitations Outcomes were limited to the correlation coefficient, as this was a commonly reported measure of analytical performance in the literature. Results should be interpreted with caution due to risk of bias related to selection of participants, reference standards, and the multiple steps involved in POC HbA1c testing. Conclusions Moderate quality evidence showed a positive
Impact of point-of-care implementation of Xpert® MTB/RIF: product vs. process innovation.
Schumacher, S G; Thangakunam, B; Denkinger, C M; Oliver, A A; Shakti, K B; Qin, Z Z; Michael, J S; Luo, R; Pai, M; Christopher, D J
2015-09-01
Both product innovation (e.g., more sensitive tests) and process innovation (e.g., a point-of-care [POC] testing programme) could improve patient outcomes. To study the respective contributions of product and process innovation in improving patient outcomes. We implemented a POC programme using Xpert(®) MTB/RIF in an out-patient clinic of a tertiary care hospital in India. We measured the impact of process innovation by comparing time to diagnosis with routine testing vs. POC testing. We measured the impact of product innovation by comparing accuracy and time to diagnosis using smear microscopy vs. POC Xpert. We enrolled 1012 patients over a 15-month period. Xpert had high accuracy, but the incremental value of one Xpert over two smears was only 6% (95%CI 3-12). Implementing Xpert as a routine laboratory test did not reduce the time to diagnosis compared to smear-based diagnosis. In contrast, the POC programme reduced the time to diagnosis by 5.5 days (95%CI 4.3-6.7), but required dedicated staff and substantial adaptation of clinic workflow. Process innovation by way of a POC Xpert programme had a greater impact on time to diagnosis than the product per se, and can yield important improvements in patient care that are complementary to those achieved by introducing innovative technologies.
Point-of-care syndrome-based, rapid diagnosis of infections on commercial ships.
Bouricha, Mehdi; Samad, Marc Abdul; Levy, Pierre-Yves; Raoult, Didier; Drancourt, Michel
2014-01-01
Suspicion of contagious disease on commercial ships tends to be poorly managed, as there is little capacity to confirm a case on board except for malaria. Here we implemented a point-of-care (POC) laboratory on one container ship and one cruise ship for the rapid syndrome-based diagnosis of infectious diseases on board. In 2012 we implemented a POC laboratory on board a freight ship and on board a cruise ship. The POC laboratory ran a total of six different color-coded, syndrome-based kits incorporating 10 different commercially available immunochromatographic tests. The POC tests were taught within 1-hour as part of training to staff without any previous knowledge in microbiology. Compared with terrestrial POCs, specific constraints included the necessity to secure POC devices into the motile ship, to use robust devices, to overcome difficulties in communicating with the core laboratory, and to overcome limited intimacy of patients. However, a total of 36 POC tests were easily performed and yielded contributive negative results. This first experiment indicates that it is possible to run POC laboratories by nonexpert staff after providing rapid teaching course on board commercial ships. Generalization of on-board POC laboratories is expected to help in improving the medical management of staff and passengers. © 2013 International Society of Travel Medicine.
Hedlin, Gunilla; Moreno, Carmen; Petersson, Carl Johan; Lilja, Gunnar; Toledano, Félix Lorente; García, Antonio Nieto; Nordvall, Lennart; Palmqvist, Mona; Rak, Sabina; Ahlstedt, Staffan; Borres, Magnus P
2009-07-01
: Allergy is a serious problem affecting approximately 1 of 4 individuals. The symptoms with and without allergy etiology are often difficult to distinguish from each other without using an IgE antibody test. The aim of this study was to investigate the performance of a new point-of-care (POC) test for IgE antibodies to relevant allergens in Europe. : IgE antibodies from children and adults with allergies recruited from allergy clinics in Sweden and Spain were analyzed for 10 allergens, suitable for the age groups, using the new POC test and ImmunoCAP laboratory test. The IgE antibody level best discriminating between positive and negative results (the cutoff point) for the different allergens of the POC test and the efficacy of the POC and the ImmunoCAP laboratory tests for diagnosing allergy compared with that of clinical diagnosis were investigated. : The estimated cutoffs for the different allergens in the POC test ranged from 0.70 to 2.56 kUA/L. Taking into account all positive allergen results in a given patient, the POC test could identify 95% of the patients with allergies. Seventy-eight percent of the allergen-specific physicians' diagnoses were identified and 97% of the negative ones. Most allergens exhibited good performance, identifying about 80% of clinically relevant cases. However, dog, mugwort, and wall pellitory would benefit from improvement. : The POC test will be a valuable adjunct in the identification or exclusion of patients with allergies and their most likely offending allergens, both in specialist and general care settings.
Allergy Diagnosis in Children and Adults: Performance of a New Point-of-Care Device, ImmunoCAP Rapid
2009-01-01
Background Allergy is a serious problem affecting approximately 1 of 4 individuals. The symptoms with and without allergy etiology are often difficult to distinguish from each other without using an IgE antibody test. The aim of this study was to investigate the performance of a new point-of-care (POC) test for IgE antibodies to relevant allergens in Europe. Methods IgE antibodies from children and adults with allergies recruited from allergy clinics in Sweden and Spain were analyzed for 10 allergens, suitable for the age groups, using the new POC test and ImmunoCAP laboratory test. The IgE antibody level best discriminating between positive and negative results (the cutoff point) for the different allergens of the POC test and the efficacy of the POC and the ImmunoCAP laboratory tests for diagnosing allergy compared with that of clinical diagnosis were investigated. Results The estimated cutoffs for the different allergens in the POC test ranged from 0.70 to 2.56 kUA/L. Taking into account all positive allergen results in a given patient, the POC test could identify 95% of the patients with allergies. Seventy-eight percent of the allergen-specific physicians' diagnoses were identified and 97% of the negative ones. Most allergens exhibited good performance, identifying about 80% of clinically relevant cases. However, dog, mugwort, and wall pellitory would benefit from improvement. Conclusions The POC test will be a valuable adjunct in the identification or exclusion of patients with allergies and their most likely offending allergens, both in specialist and general care settings. PMID:23283063
Ibrahim, Maryanne; Moyo, Sikhulile; Mohammed, Terence; Mupfumi, Lucy; Gaseitsiwe, Simani; Maswabi, Kenneth; Ajibola, Gbolahan; Gelman, Rebecca; Batlang, Oganne; Sakoi, Maureen; Auletta-Young, Chloe; Makhema, Joseph; Lockman, Shahin; Shapiro, Roger L
2017-08-15
HIV point-of-care (POC) testing allows for early infant HIV diagnosis and treatment, but POC accuracy at birth and in the setting of antiretroviral prophylaxis for the prevention of mother-to-child HIV transmission is unknown. We evaluated the Cepheid Xpert HIV-1 Qual POC test against the Roche Taqman HIV-1 DNA polymerase chain reaction (PCR) platform using dried blood spots from 15 HIV-infected and 75 HIV-exposed uninfected newborns. These infants were screened for HIV at <96 hours of life at 5 hospital maternity wards in Botswana; all infants received postexposure antiretroviral prophylaxis with single-dose nevirapine and zidovudine, and most mothers received 3-drug antiretroviral therapy in pregnancy and at delivery. Fourteen of the 15 PCR positive samples tested positive by Cepheid POC, yielding a sensitivity of 93.3% (95% confidence interval: 68.1 to 99.8). Baseline viral load among positive infants ranged from <40 to >10,000,000 copies/mL, with a median of 2403 copies/mL. The HIV RNA for the infant with false-negative POC testing was 1661 copies/mL. Of note, 2 infants with low HIV RNA (<40 and 272 copies/mL) were correctly identified as HIV positive by Cepheid POC. All the 75 PCR-negative samples tested negative by Cepheid POC, yielding a specificity of 100% (95% confidence interval: 96.1 to 100). Our study demonstrates high sensitivity and specificity for the Cepheid POC assay in the first week of life despite early infection and antiretroviral prophylaxis. This platform may be a useful approach for adding early infant HIV diagnosis to current testing programs.
Laboratory Evaluation of the Alere q Point-of-Care System for Early Infant HIV Diagnosis.
Hsiao, Nei-yuan; Dunning, Lorna; Kroon, Max; Myer, Landon
2016-01-01
Early infant diagnosis (EID) and prompt linkage to care are critical to minimise the high morbidity and mortality associated with infant HIV infection. Attrition in the "EID cascade" is common; however, point-of-care (POC) EID assays with same-day result could facilitate prompt linkage of HIV-infected infant to treatment. Despite a number of POC EID assays in development, few have been independently evaluated and data on new technologies are urgently needed to inform policy. We compared Alere q 1/2 Detect POC system laboratory test characteristics with the local standard of care (SOC), Roche CAP/CTM HIV-1 qualitative PCR in an independent laboratory-based evaluation in Cape Town, South Africa. Routinely EID samples collected between November 2013 and September 2014 were each tested by both SOC and POC systems. Repeat testing was done to troubleshoot any discrepancy between POC and SOC results. Overall, 1098 children with a median age of 47 days (IQR, 42-117) were included. Birth PCR (age <7 days) comprised of 8% (n = 92) tests while 56% (n = 620) of children tested as part of routine EID (ages 6-14 weeks). In the overall direct comparison, Alere q Detect achieved sensitivity of 95.5% (95% CI, 91.7-97.9%) and a specificity of 99.8% (95% CI, 99.1-100%). Following repeat testing of discordant samples and exclusion of any inconclusive results, the POC assay sensitivity and specificity were 96.9% (95% CI 93.4-98.9%) and 100% (lower 95% CI 98%) respectively. Among birth PCR tests the POC assay had slightly lower sensitivity (93.3% vs 96.5% in routine EID) and higher assay error rate (10% vs 5% in samples of older children, p = 0.04). Our results indicate this POC assay performs well for EID in the laboratory. The high specificity and thus high positive predictive value would suggest a positive POC result may be adequate for immediate infant ART initiation. While POC testing for EID may have particular utility for birth testing at delivery facilities, the lower
Corn, Carolyn E; Klepser, Donald G; Dering-Anderson, Allison M; Brown, Terrence G; Klepser, Michael E; Smith, Jaclyn K
2018-06-01
Acute pharyngitis is among the most common infectious diseases encountered in the United States, resulting in 13 million patient visits annually, with group A streptococcus (GAS) being a common causative pathogen. It is estimated that annual expenditures for the treatment of adult pharyngitis will exceed US$1.2 billion annually. This substantial projection reinforces the need to evaluate diagnosis and treatment of adult pharyngitis in nontraditional settings. The objective of this research is to quantify the amount of pharmacist time required to complete a point-of-care (POC) test for a patient presenting with pharyngitis symptoms. A standardized patient with pharyngitis symptoms visited 11 pharmacies for POC testing services for a total of 33 patient encounters. An observer was present at each encounter and recorded the total encounter time, divided into 9 categories. Pharmacists conducted POC testing in 1 of 2 ways: sequence 1-pharmacists performed all service-related tasks; sequence 2-both pharmacists and pharmacist interns performed service-related tasks. The average time for completion of a POC test for GAS pharyngitis was 25.3 ± 4.8 minutes. The average pharmacist participation time per encounter was 12.7 ± 3.0 minutes (sequence 1), which decreased to 2.6 ± 1.1 minutes when pharmacist interns were involved in the testing (sequence 2). Although additional studies are required to further assess service feasibility, this study indicates that a GAS POC testing service could be implemented in a community pharmacy with limited disruption or change to workflow and staff.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-02-07
... patient and provider attitudes and willingness to participate in Point-of-Care Research (POC-R). POC-R is... of a Point-of-care research innovation program by assessing the perceptions and attitudes of patients...
Selecting an A1C Point-of-Care Instrument
Yong, Ee Vonn; Rasinen, Casey
2015-01-01
A1C point-of-care (POC) instruments benefit patients with diabetes by facilitating clinician decision making that results in significant glycemic improvements. Three National Glycohemoglobin Standardization Program (NGSP)–certified POC products are available in the United States: the handheld A1CNow (formerly manufactured by Bayer Diabetes Care but now made by Chek Diagnostics) and two bench-top models called the Axis-Shield Afinion Analyzer and the Siemens DCA Vantage. This article compares the three available NGSP-certified POC products in terms of accuracy, precision, ease of use, cost, and additional features. Its goal is to aid health care facilities in conveniently identifying the A1C POC product that best meets their needs. It additionally reviews evidence that supports the continued use of A1C POC instruments in the clinical arena. PMID:26300614
NASA Astrophysics Data System (ADS)
Powless, Amy J.; Conley, Roxanna J.; Freeman, Karan A.; Muldoon, Timothy J.
2017-03-01
There exists a broad range of techniques that can be used to classify and count white blood cells in a point-of-care (POC) three-part leukocyte differential test. Improvements in lenses, light sources, and cameras for image-based POC systems have renewed interest in acridine orange (AO) as a contrast agent, whereby subpopulations of leukocytes can be differentiated by colorimetric analysis of AO fluorescence emission. We evaluated the effect on test accuracy using different AO staining and postprocessing methods in the context of an image-based POC colorimetric cell classification scheme. Thirty blood specimens were measured for percent cell counts using our POC system and a conventional hematology analyzer for comparison. Controlling the AO concentration used during whole-blood staining, the incubation time with AO, and the colorimetric ratios among the three population of leukocytes yielded a percent deviation of 0.706%, -1.534%, and -0.645% for the lymphocytes, monocytes, and granulocytes, respectively. Overall, we demonstrated that a redshift in AO fluorescence was observed at elevated AO concentrations, which lead to reproducible inaccuracy of cell counts. This study demonstrates there is a need for a strict control of the AO staining and postprocessing methods to improve test accuracy in these POC systems.
Stime, Katrina J; Garrett, Nigel; Sookrajh, Yukteshwar; Dorward, Jienchi; Dlamini, Ntuthu; Olowolagba, Ayo; Sharma, Monisha; Barnabas, Ruanne V; Drain, Paul K
2018-05-11
Many clinics in Southern Africa have long waiting times. The implementation of point-of-care (POC) tests to accelerate diagnosis and improve clinical management in resource-limited settings may improve or worsen clinic flow and waiting times. The objective of this study was to describe clinic flow with special emphasis on the impact of POC testing at a large urban public healthcare clinic in Durban, South Africa. We used time and motion methods to directly observe patients and practitioners. We created patient flow maps and recorded individual patient waiting and consultation times for patients seeking STI, TB, or HIV care. We conducted semi-structured interviews with 20 clinic staff to ascertain staff opinions on clinic flow and POC test implementation. Among 121 observed patients, the total number of queues ranged from 4 to 7 and total visit times ranged from 0:14 (hours:minutes) to 7:38. Patients waited a mean of 2:05 for standard-of-care STI management, and approximately 4:56 for STI POC diagnostic testing. Stable HIV patients who collected antiretroviral therapy refills waited a mean of 2:42 in the standard queue and 2:26 in the fast-track queue. A rapid TB test on a small sample of patients with the Xpert MTB/RIF assay and treatment initiation took a mean of 6:56, and 40% of patients presenting with TB-related symptoms were asked to return for an additional clinic visit to obtain test results. For all groups, the mean clinical assessment time with a nurse or physician was 7 to 9 min, which accounted for 2 to 6% of total visit time. Staff identified poor clinic flow and personnel shortages as areas of concern that may pose challenges to expanding POC tests in the current clinic environment. This busy urban clinic had multiple patient queues, long clinical visits, and short clinical encounters. Although POC testing ensured patients received a diagnosis sooner, it more than doubled the time STI patients spent at the clinic and did not result in same
Llibre, Alba; Shimakawa, Yusuke; Mottez, Estelle; Ainsworth, Shaun; Buivan, Tan-Phuc; Firth, Rick; Harrison, Elliott; Rosenberg, Arielle R; Meritet, Jean-François; Fontanet, Arnaud; Castan, Pablo; Madejón, Antonio; Laverick, Mark; Glass, Allison; Viana, Raquel; Pol, Stanislas; McClure, C Patrick; Irving, William Lucien; Miele, Gino; Albert, Matthew L; Duffy, Darragh
2018-04-03
Recently approved direct acting antivirals provide transformative therapies for chronic hepatitis C virus (HCV) infection. The major clinical challenge remains to identify the undiagnosed patients worldwide, many of whom live in low-income and middle-income countries, where access to nucleic acid testing remains limited. The aim of this study was to develop and validate a point-of-care (PoC) assay for the qualitative detection of HCV RNA. We developed a PoC assay for the qualitative detection of HCV RNA on the PCR Genedrive instrument. We validated the Genedrive HCV assay through a case-control study comparing results with those obtained with the Abbott RealTi m e HCV test. The PoC assay identified all major HCV genotypes, with a limit of detection of 2362 IU/mL (95% CI 1966 to 2788). Using 422 patients chronically infected with HCV and 503 controls negative for anti-HCV and HCV RNA, the Genedrive HCV assay showed 98.6% sensitivity (95% CI 96.9% to 99.5%) and 100% specificity (95% CI 99.3% to 100%) to detect HCV. In addition, melting peak ratiometric analysis demonstrated proof-of-principle for semiquantification of HCV. The test was further validated in a real clinical setting in a resource-limited country. We report a rapid, simple, portable and accurate PoC molecular test for HCV, with sensitivity and specificity that fulfils the recent FIND/WHO Target Product Profile for HCV decentralised testing in low-income and middle-income countries. This Genedrive HCV assay may positively impact the continuum of HCV care from screening to cure by supporting real-time treatment decisions. NCT02992184. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
Chibwesha, Carla J; Ford, Catherine E; Mollan, Katie R; Stringer, Jeffrey S A
2016-08-01
In the absence of early infant diagnosis (EID) and immediate antiretroviral therapy (ART), some 50% of untreated HIV-infected infants die before age 2. Conventional EID requires sophisticated instruments that are typically placed in centralized or reference laboratories. In low-resource settings, centralized systems often lead to result turnaround times of several months, long delays in diagnosis, and adverse outcomes for HIV-infected children. Our clinical trial tests the effectiveness of a new point-of-care (POC) diagnostic technology to identify HIV-infected infants and start providing them life-saving ART as soon as possible. The study uses a randomized, controlled design to test whether the Alere q platform for HIV DNA polymerase chain reaction (PCR) testing improves outcomes of HIV-infected children in Zambia. We aim to enroll 2867 HIV-exposed infants aged 4-12 weeks and to follow those who are HIV infected for 12 months as they receive HIV care at 6 public health facilities in Lusaka. The trial's primary endpoint is the proportion of HIV-infected infants in each study arm who start ART and remain alive, in care, and virally suppressed 12 months after their diagnostic blood draw. Our trial will provide evidence for the incremental benefit of implementing a POC EID strategy in low-resource settings where only off-site PCR services are currently available. The results will be useful in guiding future decisions regarding investments in POC virologic testing as part of overall pediatric AIDS mitigation strategies in sub-Saharan Africa. clinicaltrials.gov NCT02682810.
Simultaneous point-of-care detection of anemia and sickle cell disease in Tanzania: the RAPID study.
Smart, Luke R; Ambrose, Emmanuela E; Raphael, Kevin C; Hokororo, Adolfine; Kamugisha, Erasmus; Tyburski, Erika A; Lam, Wilbur A; Ware, Russell E; McGann, Patrick T
2018-02-01
Both anemia and sickle cell disease (SCD) are highly prevalent across sub-Saharan Africa, and limited resources exist to diagnose these conditions quickly and accurately. The development of simple, inexpensive, and accurate point-of-care (POC) assays represents an important advance for global hematology, one that could facilitate timely and life-saving medical interventions. In this prospective study, Robust Assays for Point-of-care Identification of Disease (RAPID), we simultaneously evaluated a POC immunoassay (Sickle SCAN™) to diagnose SCD and a first-generation POC color-based assay to detect anemia. Performed at Bugando Medical Center in Mwanza, Tanzania, RAPID tested 752 participants (age 1 day to 20 years) in four busy clinical locations. With minimally trained medical staff, the SCD POC assay diagnosed SCD with 98.1% sensitivity and 91.1% specificity. The hemoglobin POC assay had 83.2% sensitivity and 74.5% specificity for detection of severe anemia (Hb ≤ 7 g/dL). Interobserver agreement was excellent for both POC assays (r = 0.95-0.96). Results for the hemoglobin POC assay have informed the second-generation assay design to be more suitable for low-resource settings. RAPID provides practical feasibility data regarding two novel POC assays for the diagnosis of anemia and SCD in real-world field evaluations and documents the utility and potential impact of these POC assays for sub-Saharan Africa.
Whitley, Heather P; Hanson, Courtney; Parton, Jason M
2017-03-01
This prospective longitudinal study compares diabetes screenings between standard practices vs systematically offered point-of-care (POC) hemoglobin A 1c (HbA 1c ) tests in patients aged 45 years or older. Systematically screened participants (n = 164) identified 63% (n = 104) with unknown hyperglycemia and 53% (n = 88) in prediabetes. The standard practice (n = 324) screened 22% (n = 73), most commonly by blood glucose (96%); 8% (n = 6) and 33% (n = 24) were found to have diabetes and prediabetes, respectively. The association between screening outcome and screening method was statistically significant ( P = 0.005) in favor of HbA 1C HbA 1c may be the most effective method to identify patients unknowingly living in hyperglycemia. Point-of-care tests further facilitate screening evaluation in a timely and feasible fashion. © 2017 Annals of Family Medicine, Inc.
[Point-of-Care Testing in Trauma Patients - Methods and Evidence].
Dirkmann, Daniel; Britten, Martin W; Frey, Ulrich H
2018-06-01
In severely injured patients, trauma-induced coagulopathy (TIC) present at hospital admission is associated with increased transfusion requirements, morbidity and mortality. Early and effective treatment contributes to improved survival rates. Laboratory coagulation assays have long turn-around times and evidence for their usefulness, especially in the context of TIC, is weak. Due to the lack of appropriate guidance, transfusion of allogeneic blood products frequently follows a ratio-based concept (e.g., transfusion of erythrocytes and plasma in a 1 : 1 ratio). Point-of-care (PoC) tests enable the assessment of prothrombin time (PT) and activated partial thromboplastin time in few minutes. However, although normal PT in these tests allows to rule out relevant effects of several anticoagulants, they are not able to detect patients with TIC and/or requiring subsequent massive transfusion. Viscoelastic tests (VETs) make it possible to assess defects in thrombin generation, hypofibrinogenaemia, thrombocytopenia, and hyperfibrinolysis, and thus enable targeted therapy. Impairment of platelet function is the common blind spot not detectable using both standard laboratory-based tests and VETs. However, PoC platelet function tests enable to detect platelet defects and patients taking anti-platelet. Furthermore, impaired platelet function has been identified as a strong predictor for coagulopathy and massive transfusion in trauma patients. In other clinical settings, coagulation management based on VETs is associated with decreased transfusion requirements, incidence of acute kidney failure, and mortality, respectively. Data of the first small prospective randomised trial indicate superiority of VET guided coagulation management solely using coagulation factor concentrates, when compared to plasma transfusions in severe trauma. Georg Thieme Verlag KG Stuttgart · New York.
Van Dorst, Bieke; Brivio, Monica; Van Der Sar, Elfried; Blom, Marko; Reuvekamp, Simon; Tanzi, Simone; Groenhuis, Roelf; Adojutelegan, Adewole; Lous, Erik-Jan; Frederix, Filip; Stuyver, Lieven J
2016-04-15
In this manuscript, a microfluidic detection module, which allows a sensitive readout of biological assays in point-of-care (POC) tests, is presented. The proposed detection module consists of a microfluidic flow cell with an integrated Complementary Metal-Oxide-Semiconductor (CMOS)-based single photon counting optical sensor. Due to the integrated sensor-based readout, the detection module could be implemented as the core technology in stand-alone POC tests, for use in mobile or rural settings. The performance of the detection module was demonstrated in three assays: a peptide, a protein and an antibody detection assay. The antibody detection assay with readout in the detection module proved to be 7-fold more sensitive that the traditional colorimetric plate-based ELISA. The protein and peptide assay showed a lower limit of detection (LLOD) of 200 fM and 460 fM respectively. Results demonstrate that the sensitivity of the immunoassays is comparable with lab-based immunoassays and at least equal or better than current mainstream POC devices. This sensitive readout holds the potential to develop POC tests, which are able to detect low concentrations of biomarkers. This will broaden the diagnostic capabilities at the clinician's office and at patient's home, where currently only the less sensitive lateral flow and dipstick POC tests are implemented. Copyright © 2015 Elsevier B.V. All rights reserved.
Matching point-of care devices to clinicians for positive outcomes.
Utterback, Karen; Waldo, Billie H
2005-07-01
Home care clinicians' use of point-of-care (POC) technology has increased 63% in the past 5 years. Although there are more POC system choices, matching the right device to each clinician's role is a challenge. This article clarifies the uses of laptop or notebook computer, personal digital assistants (PDAs), telephony, or automated telehealth, suggesting ways these technologies can result in clinical efficiencies, care coordination, and regulatory compliance.
Point-of-care diagnostics: an advancing sector with nontechnical issues.
Huckle, David
2008-11-01
The particular reasons for the relative lack in development of point-of-care (PoC) diagnostics in a business context were discussed in our sister journal, Expert Review of Medical Devices, over 2 years ago. At that time, it could be seen that the concept of PoC testing was being revisited for at least the fifth time in the last 20 years. There had been important advances in technology but, with changes in global healthcare structures and funding, the overall in vitro diagnostics sector has had sluggish growth. Only molecular diagnostics and PoC testing are growing strongly. PoC testing is now a quarter of the total global in vitro diagnostics market, but largely due to use in diabetes monitoring. An increased focus on areas other than glucose self-testing has created a disturbance in the market. An implementation issue from this disturbance is that of control between central laboratories and the proposed sites for PoC testing. Evidence is presented to show that the first step is likely to be increased use in clinics and outpatient facilities closely linked with the laboratory. The aim will be to control the quality of the test, maintenance of equipment and provide support for the clinician in interpretation. The major problem for effective PoC implementation will be the significant changes to patient pathways that are required. The changes will benefit the patient and clinical outcomes but will require healthcare professionals to change their work patterns. This will be an uphill task!
Point-of-care testing in an organ procurement organization donor management setting.
Baier, K A; Markham, L E; Flaigle, S P; Nelson, P W; Shield, C F; Muruve, N A; Aeder, M I; Murillo, D; Bryan, C F
2003-01-01
Our organ procurement organization (OPO) evaluated the clinical and financial efficacy of point-of-care testing (POCT) in management of our deceased organ donors. Before we implemented point-of care testing with the i-STAT into routine clinical donor management, we compared the i-STAT result with the result from the respective donor hospital lab (DHL) for certain analytes on 15 consecutive donors in our OPO from 26 March to 14 May 2001. The financial impact was studied by reviewing 77 donors from July 2001 to March 2002. There was a strong correlation for each analyte between the POC and DHL test results with r-values as follows: pH 0.86; PCO2 = 0.96; PO2 = 0.98; sodium = 0.98; potassium = 0.95; chloride = 0.94; BUN = 0.98; glucose = 0.92; haematocrit = 0.87 and creatinine = 0.95. Since our OPO coordinators began using i-STAT in their routine clinical management of organ donors, they can now more quickly maximize oxygenation and fluid management of the donor and make extra-renal placement calls sooner. Finally, since we are no longer being billed for the testing performed on the i-STAT, average financial savings to our OPO are US dollars 733 per case. Point-of-care testing in management of our OPO donors provides a result that is equivalent to that of the donor hospital lab, has quicker turn-around time than the donor hospital laboratory, allowing more immediate clinical management decisions to be made so that extra-renal offers may begin sooner.
Point-of-care diagnostics: extending the laboratory network to reach the last mile.
Drain, Paul K; Rousseau, Christine
2017-03-01
More point-of-care (POC) diagnostic tests are becoming available for HIV diagnosis and treatment in resource-limited settings. These novel technologies have the potential to foster decentralized HIV care and treatment for the benefit of clinical laboratories, HIV clinics, and HIV-infected patients. There continue to be many business, technological, and operational challenges that limit product development and regulatory approval, which limits products available for the required operational and cost-effectiveness studies and delays policy adoption and implementation. Although the rapid HIV diagnostic test has been widely successful, the pathways for POC CD4 cell count and HIV viral load assay analyzers have been more challenging. We describe significant hurdles for product development, approval, and implementation, which include the business case, technical development, clinical impact, and integrating laboratory and clinical networks. The objective of this review is to highlight the obstacles for developing and implementing appropriate strategies for POC HIV testing assays to improve the clinical services for HIV-infected patients in resource-limited settings.
Wells, Sue; Rafter, Natasha; Kenealy, Timothy; Herd, Geoff; Eggleton, Kyle; Lightfoot, Rose; Arcus, Kim; Wadham, Angela; Jiang, Yannan; Bullen, Chris
2017-01-01
To assess the effect of a point of care (POC) device for testing lipids and HbA1c in addition to testing by community laboratory facilities (usual practice) on the completion of cardiovascular disease (CVD) risk assessments in general practice. We conducted a pragmatic, cluster randomised controlled trial in 20 New Zealand general practices stratified by size and rurality and randomised to POC device plus usual practice or usual practice alone (controls). Patients aged 35-79 years were eligible if they met national guideline criteria for CVD risk assessment. Data on CVD risk assessments were aggregated using a web-based decision support programme common to each practice. Data entered into the on-line CVD risk assessment form could be saved pending blood test results. The primary outcome was the proportion of completed CVD risk assessments. Qualitative data on practice processes for CVD risk assessment and feasibility of POC testing were collected at the end of the study by interviews and questionnaire. The POC testing was supported by a comprehensive quality assurance programme. A CVD risk assessment entry was recorded for 7421 patients in 10 POC practices and 6217 patients in 10 control practices; 99.5% of CVD risk assessments had complete data in both groups (adjusted odds ratio 1.02 [95%CI 0.61-1.69]). There were major external influences that affected the trial: including a national performance target for CVD risk assessment and changes to CVD guidelines. All practices had invested in systems and dedicated staff time to identify and follow up patients to completion. However, the POC device was viewed by most as an additional tool rather than as an opportunity to review practice work flow and leverage the immediate test results for patient education and CVD risk management discussions. Shortly after commencement, the trial was halted due to a change in the HbA1c test assay performance. The trial restarted after the manufacturing issue was rectified but this
Care Model Design for E-Health: Integration of Point-of-Care Testing at Dutch General Practices.
Verhees, Bart; van Kuijk, Kees; Simonse, Lianne
2017-12-21
Point-of-care testing (POCT)-laboratory tests performed with new mobile devices and online technologies outside of the central laboratory-is rapidly outpacing the traditional laboratory test market, growing at a rate of 12 to 15% each year. POCT impacts the diagnostic process of care providers by yielding high efficiency benefits in terms of turnaround time and related quality improvements in the reduction of errors. However, the implementation of this disruptive eHealth technology requires the integration and transformation of diagnostic services across the boundaries of healthcare organizations. Research has revealed both advantages and barriers of POCT implementations, yet to date, there is no business model for the integration of POCT within general practice. The aim of this article is to contribute with a design for a care model that enables the integration of POCT in primary healthcare. In this research, we used a design modelling toolkit for data collection at five general practices. Through an iterative design process, we modelled the actors and value transactions, and designed an optimized care model for the dynamic integration of POCTs into the GP's network of care delivery. The care model design will have a direct bearing on improving the integration of POCT through the connectivity and norm guidelines between the general practice, the POC technology, and the diagnostic centre.
Care Model Design for E-Health: Integration of Point-of-Care Testing at Dutch General Practices
Verhees, Bart; van Kuijk, Kees
2017-01-01
Point-of-care testing (POCT)—laboratory tests performed with new mobile devices and online technologies outside of the central laboratory—is rapidly outpacing the traditional laboratory test market, growing at a rate of 12 to 15% each year. POCT impacts the diagnostic process of care providers by yielding high efficiency benefits in terms of turnaround time and related quality improvements in the reduction of errors. However, the implementation of this disruptive eHealth technology requires the integration and transformation of diagnostic services across the boundaries of healthcare organizations. Research has revealed both advantages and barriers of POCT implementations, yet to date, there is no business model for the integration of POCT within general practice. The aim of this article is to contribute with a design for a care model that enables the integration of POCT in primary healthcare. In this research, we used a design modelling toolkit for data collection at five general practices. Through an iterative design process, we modelled the actors and value transactions, and designed an optimized care model for the dynamic integration of POCTs into the GP’s network of care delivery. The care model design will have a direct bearing on improving the integration of POCT through the connectivity and norm guidelines between the general practice, the POC technology, and the diagnostic centre. PMID:29267224
Patten, Gabriela E M; Wilkinson, Lynne; Conradie, Karien; Isaakidis, Petros; Harries, Anthony D; Edginton, Mary E; De Azevedo, Virginia; van Cutsem, Gilles
2013-07-04
Despite the rapid expansion of antiretroviral therapy (ART) programmes in developing countries, pre-treatment losses from care remain a challenge to improving access to treatment. Youth and adolescents have been identified as a particularly vulnerable group, at greater risk of loss from both pre-ART and ART care. Point-of-care (POC) CD4 testing has shown promising results in improving linkage to ART care. In Khayelitsha township, South Africa, POC CD4 testing was implemented at a clinic designated for youth aged 12-25 years. We assessed whether there was an associated reduction in attrition between HIV testing, assessment for eligibility and ART initiation. A before-and-after observational study was conducted using routinely collected data. These were collected on patients from May 2010 to April 2011 (Group A) when baseline CD4 count testing was performed in a laboratory and results were returned to the clinic within two weeks. Same-day POC CD4 testing was implemented in June 2011, and data were collected on patients from August 2011 to July 2012 (Group B). A total of 272 and 304 youth tested HIV-positive in Group A and Group B, respectively. Group B patients were twice as likely to have their ART eligibility assessed compared to Group A patients: 275 (90%) vs. 183 (67%) [relative risk (RR)=2.4, 95% CI: 1.8-3.4, p<0.0001]. More patients in World Health Organization (WHO) Stage 1 disease (85% vs. 69%), with CD4 counts≥350 cells/µL (58% vs. 35%) and more males (13% vs. 7%) were detected in Group B. The proportion of eligible patients who initiated ART was 50% and 44% (p=0.6) in Groups B and A, respectively; and 50% and 43% (p=0.5) when restricted to patients with baseline CD4 count≤250 cells/µL. Time between HIV-testing and ART initiation was reduced from 36 to 28 days (p=0.6). POC CD4 testing significantly improved assessment for ART eligibility. The improvement in the proportion initiating ART and the reduction in time to initiation was not significant due to
Integrating Point-of-Care Testing into a Community Emergency Department: A Mixed-Methods Evaluation.
Pines, Jesse M; Zocchi, Mark S; Carter, Caitlin; Marriott, Charles Z; Bernard, Matthew; Warner, Leah H
2018-05-13
Point-of-care testing (POCT) is a commonly used technology that hastens the time to laboratory results in emergency departments (ED). We evaluated an ED-based POCT program on ED length of stay and time to care, coupled with qualitative interviews of local ED stakeholders. We conducted a mixed-methods study (2012-16) to examine the impact of point-of-care testing in a single, community ED. The quantiative analysis involved an observational before-after study comparing time to laboratory test result (POC troponin or POC chemistry) and ED length of stay after implementation of POCT, using a propensity-weighted interrupted time series analysis (ITSA). A complementary qualitative analysis involved five semi-structured interviews with staff using grounded theory on the benefits and challenges to ED POCT. A total of 47,399 ED visits were included in the study (24,705 in pre-intervention period and 22,694 in post-intervention). After POCT implementation, overall laboratory testing increased marginally from 61 to 62%. Central laboratory troponin and chemistry declined by >50% and was replaced by POCT. Prior to POCT implementation, time to troponin and chemistry had declined steadily due to other improvements in laboratory efficiency. After POCT implementation, there was an immediate 20 minute further decline (p<0.001) in both time to troponin and time to chemistry results using the propensity-weighted comparisons. However, the declining trend observed prior to POCT implementation did not continue at the same rate post implementation. Similarly, prior to POCT implementation, ED length of stay (LOS) declined due to other quality improvements. After POCT implementation, LOS continued declined at a similar rate. Because of this prior trend, the ITSA did not show a significant decline in LOS attributable to POCT. Common benefits of POCT perceived by staff in qualitative interviews included improved quality of care (64%), and reductions in time to test results (44%). Common
Current Nucleic Acid Extraction Methods and Their Implications to Point-of-Care Diagnostics.
Ali, Nasir; Rampazzo, Rita de Cássia Pontello; Costa, Alexandre Dias Tavares; Krieger, Marco Aurelio
2017-01-01
Nucleic acid extraction (NAE) plays a vital role in molecular biology as the primary step for many downstream applications. Many modifications have been introduced to the original 1869 method. Modern processes are categorized into chemical or mechanical, each with peculiarities that influence their use, especially in point-of-care diagnostics (POC-Dx). POC-Dx is a new approach aiming to replace sophisticated analytical machinery with microanalytical systems, able to be used near the patient, at the point of care or point of need . Although notable efforts have been made, a simple and effective extraction method is still a major challenge for widespread use of POC-Dx. In this review, we dissected the working principle of each of the most common NAE methods, overviewing their advantages and disadvantages, as well their potential for integration in POC-Dx systems. At present, it seems difficult, if not impossible, to establish a procedure which can be universally applied to POC-Dx. We also discuss the effects of the NAE chemicals upon the main plastic polymers used to mass produce POC-Dx systems. We end our review discussing the limitations and challenges that should guide the quest for an efficient extraction method that can be integrated in a POC-Dx system.
Current Nucleic Acid Extraction Methods and Their Implications to Point-of-Care Diagnostics
Ali, Nasir; Rampazzo, Rita de Cássia Pontello; Krieger, Marco Aurelio
2017-01-01
Nucleic acid extraction (NAE) plays a vital role in molecular biology as the primary step for many downstream applications. Many modifications have been introduced to the original 1869 method. Modern processes are categorized into chemical or mechanical, each with peculiarities that influence their use, especially in point-of-care diagnostics (POC-Dx). POC-Dx is a new approach aiming to replace sophisticated analytical machinery with microanalytical systems, able to be used near the patient, at the point of care or point of need. Although notable efforts have been made, a simple and effective extraction method is still a major challenge for widespread use of POC-Dx. In this review, we dissected the working principle of each of the most common NAE methods, overviewing their advantages and disadvantages, as well their potential for integration in POC-Dx systems. At present, it seems difficult, if not impossible, to establish a procedure which can be universally applied to POC-Dx. We also discuss the effects of the NAE chemicals upon the main plastic polymers used to mass produce POC-Dx systems. We end our review discussing the limitations and challenges that should guide the quest for an efficient extraction method that can be integrated in a POC-Dx system. PMID:28785592
Kost, Gerald J; Ferguson, William J; Hoe, Jackie; Truong, Anh-Thu; Banpavichit, Arirat; Kongpila, Surin
2015-01-01
To present a vision where point-of-care testing (POCT) accelerates an Ebola Spatial Care Path™ (SCP) and future molecular diagnostics enable facilitated-access self-testing (FAST POC); to design an alternate care facility (ACF) for the SCP; to innovate an Ebola diagnostic center (DC); and to propel rapid POCT to the frontline to create resilience that stops future outbreaks. PubMed, literature, and web searches. Centers for Disease Control and Prevention (CDC), Food and Drug Administration (FDA), Medicine Without Frontiers, and World Health Organization (WHO) document analyses. Investigations in China, the Philippines, Thailand, and the United States. Review of SE Asia, US, and West Africa isolation-treatment centers. Innovation of a SCP, ACF, and DC suitable for American and other communities. The authors designed an ACF and DC to integrate SCP principles for urgent Ebola care. FDA emergency use authorizations for Ebola molecular diagnostics were discovered, but no portable, handheld, or self-contained molecular POC instruments are yet available, although feasible. The WHO initiated design criteria and an acceptance protocol for testing. Financial investment in POCT will downsize Ebola outbreaks. POCT is facilitating global health. Now, global health problems are elevating POCT to new levels of importance for accelerating diagnosis and evidence-based decision making during disease outbreaks. Authorities concur that rapid diagnosis has potential to stop disease spread. With embedded POCT, strategic SCPs planned by communities fulfill CDC recommendations. POC devices should consolidate multiplex test clusters supporting patients with Ebola in isolation. The ultimate future solution is FAST POC. New technologies offer minimally significant risks. Diagnostic centers in ACFs and transportable formats also will optimize Ebola SCPs.
Gonzalez, Jesus M.; Francis, Bryan; Burda, Sherri; Hess, Kaitlyn; Behera, Digamber; Gupta, Dheeraj; Agarwal, Ashutosh Nath; Verma, Indu; Verma, Ajoy; Myneedu, Vithal Prasad; Niedbala, Sam; Laal, Suman
2014-01-01
The need for an accurate, rapid, simple and affordable point-of-care (POC) test for Tuberculosis (TB) that can be implemented in microscopy centers and other peripheral health-care settings in the TB-endemic countries remains unmet. This manuscript describes preliminary results of a new prototype rapid lateral flow TB test based on detection of antibodies to immunodominant epitopes (peptides) derived from carefully selected, highly immunogenic M. tuberculosis cell-wall proteins. Peptide selection was initially based on recognition by antibodies in sera from TB patients but not in PPD-/PPD+/BCG-vaccinated individuals from TB-endemic settings. The peptides were conjugated to BSA; the purified peptide-BSA conjugates striped onto nitrocellulose membrane and adsorbed onto colloidal gold particles to devise the prototype test, and evaluated for reactivity with sera from 3 PPD-, 29 PPD+, 15 PPD-unknown healthy subjects, 10 patients with non-TB lung disease and 124 smear-positive TB patients. The assay parameters were adjusted to determine positive/negative status within 15 minutes via visual or instrumented assessment. There was minimal or no reactivity of sera from non-TB subjects with the striped BSA-peptides demonstrating the lack of anti-peptide antibodies in subjects with latent TB and/or BCG vaccination. Sera from most TB patients demonstrated reactivity with one or more peptides. The sensitivity of antibody detection ranged from 28–85% with the 9 BSA-peptides. Three peptides were further evaluated with sera from 400 subjects, including additional PPD-/PPD+/PPD-unknown healthy contacts, close hospital contacts and household contacts of untreated TB patients, patients with non-TB lung disease, and HIV+TB- patients. Combination of the 3 peptides provided sensitivity and specificity>90%. While the final fully optimized lateral flow POC test for TB is under development, these preliminary results demonstrate that an antibody-detection based rapid POC lateral flow test
Kim, Chloe S; Vanture, Sarah; Cho, Margaret; Klapperich, Catherine M; Wang, Catharine; Huang, Franklin W
2016-01-01
Well-developed point-of-care (POC) cancer screening tools have the potential to provide better cancer care to patients in both developed and developing countries. However, new medical technology will not be adopted by medical providers unless it addresses a population's existing needs and end-users' preferences. The goals of our study were to assess primary care providers' level of awareness, interest, and preferences in using POC cancer screening technology in their practice and to provide guidelines to biomedical engineers for future POC technology development. A total of 350 primary care providers completed a one-time self-administered online survey, which took approximately 10 minutes to complete. A $50 Amazon gift card was given as an honorarium for the first 100 respondents to encourage participation. The description of POC cancer screening technology was provided in the beginning of the survey to ensure all participants had a basic understanding of what constitutes POC technology. More than half of the participants (57%) stated that they heard of the term "POC technology" for the first time when they took the survey. However, almost all of the participants (97%) stated they were either "very interested" (68%) or "somewhat interested" (29%) in using POC cancer screening technology in their practice. Demographic characteristics such as the length of being in the practice of medicine, the percentage of patients on Medicaid, and the average number of patients per day were not shown to be associated with the level of interest in using POC. These data show that there is a great interest in POC cancer screening technology utilization among this population of primary care providers and vast room for future investigations to further understand the interest and preferences in using POC cancer technology in practice. Ensuring that the benefits of new technology outweigh the costs will maximize the likelihood it will be used by medical providers and patients.
Clinical accuracy of point-of-care urine culture in general practice.
Holm, Anne; Cordoba, Gloria; Sørensen, Tina Møller; Jessen, Lisbeth Rem; Frimodt-Møller, Niels; Siersma, Volkert; Bjerrum, Lars
2017-06-01
To assess the clinical accuracy (sensitivity (SEN), specificity (SPE), positive predictive value and negative predictive value) of two point-of-care (POC) urine culture tests for the identification of urinary tract infection (UTI) in general practice. Prospective diagnostic accuracy study comparing two index tests (Flexicult™ SSI-Urinary Kit or ID Flexicult™) with a reference standard (urine culture performed in the microbiological department). General practice in the Copenhagen area patients. Adult female patients consulting their general practitioner with suspected uncomplicated, symptomatic UTI. (1) Overall accuracy of POC urine culture in general practice. (2) Individual accuracy of each of the two POC tests in this study. (3) Accuracy of POC urine culture in general practice with enterococci excluded, since enterococci are known to multiply in boric acid used for transportation for the reference standard. (4) Accuracy based on expert reading of photographs of POC urine cultures performed in general practice. Standard culture performed in the microbiological department was used as reference standard for all four measures. Twenty general practices recruited 341 patients with suspected uncomplicated UTI. The overall agreement between index test and reference was 0.76 (CI: 0.71-0.80), SEN 0.88 (CI: 0.83-0.92) and SPE 0.55 (CI: 0.46-0.64). The two POC tests produced similar results individually. Overall agreement with enterococci excluded was 0.82 (0.77-0.86) and agreement between expert readings of photographs and reference results was 0.81 (CI: 0.76-0.85). POC culture used in general practice has high SEN but low SPE. Low SPE could be due to both misinterpretation in general practice and an imperfect reference standard. Registration number: ClinicalTrials.gov NCT02323087.
Flexible substrate-based devices for point-of-care diagnostics
Wang, ShuQi; Chinnasamy, Thiruppathiraja; Lifson, Mark; Inci, Fatih; Demirci, Utkan
2016-01-01
Point-of-care (POC) diagnostics play an important role in delivering healthcare, particularly for clinical management and disease surveillance in both developed and developing countries. Currently, the majority of POC diagnostics utilize paper substrates owing to their affordability, disposability, and mass production capability. Recently, flexible polymer substrates have been investigated due to their enhanced physicochemical properties, potential to be integrated into wearable devices with wireless communications for personalized health monitoring, and ability to be customized for POC diagnostics. Here, we focus on the latest advances in developing flexible substrate-based diagnostic devices, including paper and polymers, and their clinical applications at the POC. PMID:27344425
Ceriotti, Ferruccio; Kaczmarek, Ewa; Guerra, Elena; Mastrantonio, Fabrizio; Lucarelli, Fausto; Valgimigli, Francesco; Mosca, Andrea
2015-03-01
Point-of-care (POC) testing devices for monitoring glucose and ketones can play a key role in the management of dysglycemia in hospitalized diabetes patients. The accuracy of glucose devices can be influenced by biochemical changes that commonly occur in critically ill hospital patients and by the medication prescribed. Little is known about the influence of these factors on ketone POC measurements. The aim of this study was to assess the analytical performance of POC hospital whole-blood glucose and ketone meters and the extent of glucose interference factors on the design and accuracy of ketone results. StatStrip glucose/ketone, Optium FreeStyle glucose/ketone, and Accu-Chek Performa glucose were also assessed and results compared to a central laboratory reference method. The analytical evaluation was performed according to Clinical and Laboratory Standards Institute (CLSI) protocols for precision, linearity, method comparison, and interference. The interferences assessed included acetoacetate, acetaminophen, ascorbic acid, galactose, maltose, uric acid, and sodium. The accuracies of both Optium ketone and glucose measurements were significantly influenced by varying levels of hematocrit and ascorbic acid. StatStrip ketone and glucose measurements were unaffected by the interferences tested with exception of ascorbic acid, which reduced the higher level ketone value. The accuracy of Accu-Chek glucose measurements was affected by hematocrit, by ascorbic acid, and significantly by galactose. The method correlation assessment indicated differences between the meters in compliance to ISO 15197 and CLSI 12-A3 performance criteria. Combined POC glucose/ketone methods are now available. The use of these devices in a hospital setting requires careful consideration with regard to the selection of instruments not sensitive to hematocrit variation and presence of interfering substances. © 2014 Diabetes Technology Society.
Kuupiel, Desmond; Bawontuo, Vitalis; Mashamba-Thompson, Tivani P
2017-11-29
Access to point-of-care (POC) diagnostics services is essential for ensuring rapid disease diagnosis, management, control, and surveillance. POC testing services can improve access to healthcare especially where healthcare infrastructure is weak and access to quality and timely medical care is a challenge. Improving the accessibility and efficiency of POC diagnostics services, particularly in resource-limited settings, may be a promising route to improving healthcare outcomes. In this review, the accessibility of POC testing is defined as the distance/proximity to the nearest healthcare facility for POC diagnostics service. This review provides an overview of the impact of POC diagnostics on healthcare outcomes in low- and middle-income countries (LMICs) and factors contributing to the accessibility of POC testing services in LMICs, focusing on characteristics of the supply chain management and quality systems management, characteristics of the geographical location, health infrastructure, and an enabling policy framework for POC diagnostics services. Barriers and challenges related to the accessibility of POC diagnostics in LMICs were also discussed. Bearing in mind the reported barriers and challenges as well as the disease epidemiology in LMICs, we propose a lean and agile supply chain management framework for improving the accessibility and efficiency of POC diagnostics services in these settings.
Kuupiel, Desmond; Bawontuo, Vitalis
2017-01-01
Access to point-of-care (POC) diagnostics services is essential for ensuring rapid disease diagnosis, management, control, and surveillance. POC testing services can improve access to healthcare especially where healthcare infrastructure is weak and access to quality and timely medical care is a challenge. Improving the accessibility and efficiency of POC diagnostics services, particularly in resource-limited settings, may be a promising route to improving healthcare outcomes. In this review, the accessibility of POC testing is defined as the distance/proximity to the nearest healthcare facility for POC diagnostics service. This review provides an overview of the impact of POC diagnostics on healthcare outcomes in low- and middle-income countries (LMICs) and factors contributing to the accessibility of POC testing services in LMICs, focusing on characteristics of the supply chain management and quality systems management, characteristics of the geographical location, health infrastructure, and an enabling policy framework for POC diagnostics services. Barriers and challenges related to the accessibility of POC diagnostics in LMICs were also discussed. Bearing in mind the reported barriers and challenges as well as the disease epidemiology in LMICs, we propose a lean and agile supply chain management framework for improving the accessibility and efficiency of POC diagnostics services in these settings. PMID:29186013
Mauk, Michael G.; Song, Jinzhao; Liu, Changchun; Bau, Haim H.
2018-01-01
Designs and applications of microfluidics-based devices for molecular diagnostics (Nucleic Acid Amplification Tests, NAATs) in infectious disease testing are reviewed, with emphasis on minimally instrumented, point-of-care (POC) tests for resource-limited settings. Microfluidic cartridges (‘chips’) that combine solid-phase nucleic acid extraction; isothermal enzymatic nucleic acid amplification; pre-stored, paraffin-encapsulated lyophilized reagents; and real-time or endpoint optical detection are described. These chips can be used with a companion module for separating plasma from blood through a combined sedimentation-filtration effect. Three reporter types: Fluorescence, colorimetric dyes, and bioluminescence; and a new paradigm for end-point detection based on a diffusion-reaction column are compared. Multiplexing (parallel amplification and detection of multiple targets) is demonstrated. Low-cost detection and added functionality (data analysis, control, communication) can be realized using a cellphone platform with the chip. Some related and similar-purposed approaches by others are surveyed. PMID:29495424
Internet Point of Care Learning at a Community Hospital
ERIC Educational Resources Information Center
Sinusas, Keith
2009-01-01
Introduction: Internet point of care (PoC) learning is a relatively new method for obtaining continuing medical education credits. Few data are available to describe physician utilization of this CME activity. Methods: We describe the Internet point of care system we developed at a medium-sized community hospital and report on its first year of…
Ciaranello, Andrea L; Myer, Landon; Kelly, Kathleen; Christensen, Sarah; Daskilewicz, Kristen; Doherty, Katie; Bekker, Linda-Gail; Hou, Taige; Wood, Robin; Francke, Jordan A; Wools-Kaloustian, Kara; Freedberg, Kenneth A; Walensky, Rochelle P
2015-01-01
Many prevention of mother-to-child HIV transmission (PMTCT) programs currently prioritize antiretroviral therapy (ART) for women with advanced HIV. Point-of-care (POC) CD4 assays may expedite the selection of three-drug ART instead of zidovudine, but are costlier than traditional laboratory assays. We used validated models of HIV infection to simulate pregnant, HIV-infected women (mean age 26 years, gestational age 26 weeks) in a general antenatal clinic in South Africa, and their infants. We examined two strategies for CD4 testing after HIV diagnosis: laboratory (test rate: 96%, result-return rate: 87%, cost: $14) and POC (test rate: 99%, result-return rate: 95%, cost: $26). We modeled South African PMTCT guidelines during the study period (WHO "Option A"): antenatal zidovudine (CD4 ≤350/μL) or ART (CD4>350/μL). Outcomes included MTCT risk at weaning (age 6 months), maternal and pediatric life expectancy (LE), maternal and pediatric lifetime healthcare costs (2013 USD), and cost-effectiveness ($/life-year saved). In the base case, laboratory led to projected MTCT risks of 5.7%, undiscounted pediatric LE of 53.2 years, and undiscounted PMTCT plus pediatric lifetime costs of $1,070/infant. POC led to lower modeled MTCT risk (5.3%), greater pediatric LE (53.4 years) and lower PMTCT plus pediatric lifetime costs ($1,040/infant). Maternal outcomes following laboratory were similar to POC (LE: 21.2 years; lifetime costs: $23,860/person). Compared to laboratory, POC improved clinical outcomes and reduced healthcare costs. In antenatal clinics implementing Option A, the higher initial cost of a one-time POC CD4 assay will be offset by cost-savings from prevention of pediatric HIV infection.
Weigl, Bernhard H; Neogi, Tina; McGuire, Helen
2014-06-01
The emergence of point-of-care (POC) diagnostics specifically designed for low-resource settings coupled with the rapid increase in need for routine care of patients with chronic diseases should prompt reconsideration of how health care can be delivered most beneficially and cost-effectively in developing countries. Bolstering support for primary care to provide rapid and appropriate integrated acute and chronic care treatment may be a possible solution. POC diagnostics can empower local and primary care providers and enable them to make better clinical decisions. This article explores the opportunity for POC diagnostics to strengthen primary care and chronic disease diagnosis and management in a low-resource setting (LRS) to deliver appropriate, consistent, and integrated care. We analyze the requirements of resource-appropriate chronic disease care, the characteristics of POC diagnostics in LRS versus the developed world, the many roles of diagnostics in the care continuum in LRS, and the process and economics of developing LRS-compatible POC diagnostics. © 2013 Society for Laboratory Automation and Screening.
Kim, Chloe S.; Vanture, Sarah; Cho, Margaret; Klapperich, Catherine M.; Wang, Catharine; Huang, Franklin W.
2016-01-01
Well-developed point-of-care (POC) cancer screening tools have the potential to provide better cancer care to patients in both developed and developing countries. However, new medical technology will not be adopted by medical providers unless it addresses a population’s existing needs and end-users’ preferences. The goals of our study were to assess primary care providers’ level of awareness, interest, and preferences in using POC cancer screening technology in their practice and to provide guidelines to biomedical engineers for future POC technology development. A total of 350 primary care providers completed a one-time self-administered online survey, which took approximately 10 minutes to complete. A $50 Amazon gift card was given as an honorarium for the first 100 respondents to encourage participation. The description of POC cancer screening technology was provided in the beginning of the survey to ensure all participants had a basic understanding of what constitutes POC technology. More than half of the participants (57%) stated that they heard of the term “POC technology” for the first time when they took the survey. However, almost all of the participants (97%) stated they were either “very interested” (68%) or “somewhat interested” (29%) in using POC cancer screening technology in their practice. Demographic characteristics such as the length of being in the practice of medicine, the percentage of patients on Medicaid, and the average number of patients per day were not shown to be associated with the level of interest in using POC. These data show that there is a great interest in POC cancer screening technology utilization among this population of primary care providers and vast room for future investigations to further understand the interest and preferences in using POC cancer technology in practice. Ensuring that the benefits of new technology outweigh the costs will maximize the likelihood it will be used by medical providers and
Advances in point-of-care technologies for molecular diagnostics.
Zarei, Mohammad
2017-12-15
Advances in miniaturization, nanotechnology, and microfluidics, along with developments in cloud-connected point-of-care (POC) diagnostics technologies are pushing the frontiers of POC devices toward low-cost, user-friendly, and enhanced sensitivity molecular-level diagnostics. The combination of various bio-sensing platforms within smartphone-integrated electronic readers provides accurate on-site and on-time diagnostics based on various types of chemical and biological targets. Further, 3D printing technology shows a huge potential toward fabrication and improving the performance of POC devices. Integration of skin-like flexible sensors with wireless communication technology creates a unique opportunity for continuous, real-time monitoring of patients for both preventative healthcare and during disease outbreaks. Here, we review recent developments and advances in POC technologies and describe how these advances enhance the performance of POC platforms. Also, this review describes challenges, directions, and future trends on application of emerging technologies in POC diagnostics. Copyright © 2017 Elsevier B.V. All rights reserved.
Maas, Matthew B; Naidech, Andrew M; Kim, Minjee; Batra, Ayush; Manno, Edward M; Sorond, Farzaneh A; Prabhakaran, Shyam; Liotta, Eric M
2018-05-01
We evaluated whether reduced platelet activity detected by point-of-care (POC) testing is a better predictor of hematoma expansion and poor functional outcomes in patients with intracerebral hemorrhage (ICH) than a history of antiplatelet medication exposure. Patients presenting with spontaneous ICH were enrolled in a prospective observational cohort study that collected demographic, clinical, laboratory, and radiographic data. We measured platelet activity using the PFA-100 (Siemens AG, Germany) and VerifyNow-ASA (Accumetrics, CA) systems on admission. We performed univariate and adjusted multivariate analyses to assess the strength of association between those measures and (1) hematoma growth at 24 hours and (2) functional outcomes measured by the modified Rankin Scale (mRS) at 3 months. We identified 278 patients for analysis (mean age 65 ± 15, median ICH score 1 [interquartile range 0-2]), among whom 164 underwent initial neuroimaging within 6 hours of symptom onset. Univariate association with hematoma growth was stronger for antiplatelet medication history than POC measures, which was confirmed in multivariable models (β 3.64 [95% confidence interval [CI] 1.02-6.26], P = .007), with a larger effect size measured in the under 6-hour subgroup (β 7.20 [95% CI 3.35-11.1], P < .001). Moreover, antiplatelet medication history, but not POC measures of platelet activity, was independently associated with poor outcome at 3 months (mRS 4-6) in the under 6-hour subgroup (adjusted OR 3.6 [95% CI 1.2-11], P = .023). A history of antiplatelet medication use better identifies patients at risk for hematoma growth and poor functional outcomes than POC measures of platelet activity after spontaneous ICH. Copyright © 2018 National Stroke Association. Published by Elsevier Inc. All rights reserved.
Zeh, Clement; Rose, Charles E; Inzaule, Seth; Desai, Mitesh A; Otieno, Fredrick; Humwa, Felix; Akoth, Benta; Omolo, Paul; Chen, Robert T; Kebede, Yenew; Samandari, Taraz
2017-09-01
CD4+ T-lymphocyte count testing at the point-of-care (POC) may improve linkage to care of persons diagnosed with HIV-1 infection, but the accuracy of POC devices when operated by lay-counselors in the era of task-shifting is unknown. We examined the accuracy of Alere's Pima™ POC device on both capillary and venous blood when performed by lay-counselors and laboratory technicians. In Phase I, we compared the perfomance of POC against FACSCalibur™ for 280 venous specimens by laboratory technicians. In Phase II we compared POC performance by lay-counselors versus laboratory technicians using 147 paired capillary and venous specimens, and compared these to FACSCalibur™. Statistical analyses included Bland-Altman analyses, concordance correlation coefficient, sensitivity, and specificity at treatment eligibility thresholds of 200, 350, and 500cells/μl. Phase I: POC sensitivity and specificity were 93.0% and 84.1% at 500cells/μl, respectively. Phase II: Good agreement was observed for venous POC results from both lay-counselors (concordance correlation coefficient (CCC)=0.873, bias -86.4cells/μl) and laboratory technicians (CCC=0.920, bias -65.7cells/μl). Capillary POC had good correlation: lay-counselors (CCC=0.902, bias -71.2cells/μl), laboratory technicians (CCC=0.918, bias -63.0cells/μl). Misclassification at the 500 cells/μl threshold for venous blood was 13.6% and 10.2% for lay-counselors and laboratory technicians and 12.2% for capillary blood in both groups. POC tended to under-classify the CD4 values with increasingly negative bias at higher CD4 values. Pima™ results were comparable to FACSCalibur™ for both venous and capillary specimens when operated by lay-counselors. POC CD4 testing has the potential to improve linkage to HIV care without burdening laboratory technicians in resource-limited settings. Published by Elsevier B.V.
NASA Astrophysics Data System (ADS)
Berg, Brandon; Cortazar, Bingen; Tseng, Derek; Ozkan, Haydar; Feng, Steve; Wei, Qingshan; Chan, Raymond Y.; Burbano, Jordi; Farooqui, Qamar; Lewinski, Michael; Di Carlo, Dino; Garner, Omai B.; Ozcan, Aydogan
2016-03-01
Enzyme-linked immunosorbent assay (ELISA) in a microplate format has been a gold standard first-line clinical test for diagnosis of various diseases including infectious diseases. However, this technology requires a relatively large and expensive multi-well scanning spectrophotometer to read and quantify the signal from each well, hindering its implementation in resource-limited-settings. Here, we demonstrate a cost-effective and handheld smartphone-based colorimetric microplate reader for rapid digitization and quantification of immunoserology-related ELISA tests in a conventional 96-well plate format at the point of care (POC). This device consists of a bundle of 96 optical fibers to collect the transmitted light from each well of the microplate and direct all the transmission signals from the wells onto the camera of the mobile-phone. Captured images are then transmitted to a remote server through a custom-designed app, and both quantitative and qualitative diagnostic results are returned back to the user within ~1 minute per 96-well plate by using a machine learning algorithm. We tested this mobile-phone based micro-plate reader in a clinical microbiology lab using FDA-approved mumps IgG, measles IgG, and herpes simplex virus IgG (HSV-1 and HSV-2) ELISA tests on 1138 remnant patient samples (roughly 50% training and 50% testing), and achieved an overall accuracy of ~99% or higher for each ELISA test. This handheld and cost-effective platform could be immediately useful for large-scale vaccination monitoring in low-infrastructure settings, and also for other high-throughput disease screening applications at POC.
Flexible Substrate-Based Devices for Point-of-Care Diagnostics.
Wang, ShuQi; Chinnasamy, Thiruppathiraja; Lifson, Mark A; Inci, Fatih; Demirci, Utkan
2016-11-01
Point-of-care (POC) diagnostics play an important role in delivering healthcare, particularly for clinical management and disease surveillance in both developed and developing countries. Currently, the majority of POC diagnostics utilize paper substrates owing to affordability, disposability, and mass production capability. Recently, flexible polymer substrates have been investigated due to their enhanced physicochemical properties, potential to be integrated into wearable devices with wireless communications for personalized health monitoring, and ability to be customized for POC diagnostics. Here, we focus on the latest advances in developing flexible substrate-based diagnostic devices, including paper and polymers, and their clinical applications. Copyright © 2016 Elsevier Ltd. All rights reserved.
Augmenting epidemiological models with point-of-care diagnostics data
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pullum, Laura L.; Ramanathan, Arvind; Nutaro, James J.
Although adoption of newer Point-of-Care (POC) diagnostics is increasing, there is a significant challenge using POC diagnostics data to improve epidemiological models. In this work, we propose a method to process zip-code level POC datasets and apply these processed data to calibrate an epidemiological model. We specifically develop a calibration algorithm using simulated annealing and calibrate a parsimonious equation-based model of modified Susceptible-Infected-Recovered (SIR) dynamics. The results show that parsimonious models are remarkably effective in predicting the dynamics observed in the number of infected patients and our calibration algorithm is sufficiently capable of predicting peak loads observed in POC diagnosticsmore » data while staying within reasonable and empirical parameter ranges reported in the literature. Additionally, we explore the future use of the calibrated values by testing the correlation between peak load and population density from Census data. Our results show that linearity assumptions for the relationships among various factors can be misleading, therefore further data sources and analysis are needed to identify relationships between additional parameters and existing calibrated ones. As a result, calibration approaches such as ours can determine the values of newly added parameters along with existing ones and enable policy-makers to make better multi-scale decisions.« less
Augmenting epidemiological models with point-of-care diagnostics data
Pullum, Laura L.; Ramanathan, Arvind; Nutaro, James J.; ...
2016-04-20
Although adoption of newer Point-of-Care (POC) diagnostics is increasing, there is a significant challenge using POC diagnostics data to improve epidemiological models. In this work, we propose a method to process zip-code level POC datasets and apply these processed data to calibrate an epidemiological model. We specifically develop a calibration algorithm using simulated annealing and calibrate a parsimonious equation-based model of modified Susceptible-Infected-Recovered (SIR) dynamics. The results show that parsimonious models are remarkably effective in predicting the dynamics observed in the number of infected patients and our calibration algorithm is sufficiently capable of predicting peak loads observed in POC diagnosticsmore » data while staying within reasonable and empirical parameter ranges reported in the literature. Additionally, we explore the future use of the calibrated values by testing the correlation between peak load and population density from Census data. Our results show that linearity assumptions for the relationships among various factors can be misleading, therefore further data sources and analysis are needed to identify relationships between additional parameters and existing calibrated ones. As a result, calibration approaches such as ours can determine the values of newly added parameters along with existing ones and enable policy-makers to make better multi-scale decisions.« less
Point-of-Care Technologies for Precision Cardiovascular Care and Clinical Research
King, Kevin; Grazette, Luanda P.; Paltoo, Dina N.; McDevitt, John T.; Sia, Samuel K.; Barrett, Paddy M.; Apple, Fred S.; Gurbel, Paul A.; Weissleder, Ralph; Leeds, Hilary; Iturriaga, Erin J.; Rao, Anupama; Adhikari, Bishow; Desvigne-Nickens, Patrice; Galis, Zorina S.; Libby, Peter
2016-01-01
Point-of-care technologies (POC or POCT) are enabling innovative cardiovascular diagnostics that promise to improve patient care across diverse clinical settings. The National Heart, Lung, and Blood Institute convened a working group to discuss POCT in cardiovascular medicine. The multidisciplinary working group, which included clinicians, scientists, engineers, device manufacturers, regulatory officials, and program staff, reviewed the state of the POCT field; discussed opportunities for POCT to improve cardiovascular care, realize the promise of precision medicine, and advance the clinical research enterprise; and identified barriers facing translation and integration of POCT with existing clinical systems. A POCT development roadmap emerged to guide multidisciplinary teams of biomarker scientists, technologists, health care providers, and clinical trialists as they: 1) formulate needs assessments; 2) define device design specifications; 3) develop component technologies and integrated systems; 4) perform iterative pilot testing; and 5) conduct rigorous prospective clinical testing to ensure that POCT solutions have substantial effects on cardiovascular care. PMID:26977455
Access and Quality of HIV-Related Point-of-Care Diagnostic Testing in Global Health Programs.
Fonjungo, Peter N; Boeras, Debrah I; Zeh, Clement; Alexander, Heather; Parekh, Bharat S; Nkengasong, John N
2016-02-01
Access to point-of-care testing (POCT) improves patient care, especially in resource-limited settings where laboratory infrastructure is poor and the bulk of the population lives in rural settings. However, because of challenges in rolling out the technology and weak quality assurance measures, the promise of human immunodeficiency virus (HIV)-related POCT in resource-limited settings has not been fully exploited to improve patient care and impact public health. Because of these challenges, the Joint United Nations Programme on HIV/AIDS (UNAIDS), in partnership with other organizations, recently launched the Diagnostics Access Initiative. Expanding HIV programs, including the "test and treat" strategies and the newly established UNAIDS 90-90-90 targets, will require increased access to reliable and accurate POCT results. In this review, we examine various components that could improve access and uptake of quality-assured POC tests to ensure coverage and public health impact. These components include evaluation, policy, regulation, and innovative approaches to strengthen the quality of POCT. © The Author 2015. Published by Oxford University Press for the Infectious Diseases Society of America. All rights reserved. For permissions, e-mail journals.permissions@oup.com.
Point of Care Technologies for HIV
Hewlett, Indira K.
2014-01-01
Effective prevention of HIV/AIDS requires early diagnosis, initiation of therapy, and regular plasma viral load monitoring of the infected individual. In addition, incidence estimation using accurate and sensitive assays is needed to facilitate HIV prevention efforts in the public health setting. Therefore, more affordable and accessible point-of-care (POC) technologies capable of providing early diagnosis, HIV viral load measurements, and CD4 counts in settings where HIV is most prevalent are needed to enable appropriate intervention strategies and ultimately stop transmission of the virus within these populations to achieve the future goal of an AIDS-free generation. This review discusses the available and emerging POC technologies for future application to these unmet public health needs. PMID:24579041
Nano-Calorimetry based point of care biosensor for metabolic disease management.
Kazura, Evan; Lubbers, Brad R; Dawson, Elliott; Phillips, John A; Baudenbacher, Franz
2017-09-01
Point of care (POC) diagnostics represents one of the fastest growing health care technology segments. Developments in microfabrication have led to the development of highly-sensitive nanocalorimeters ideal for directly measuring heat generated in POC biosensors. Here we present a novel nano-calorimeter-based biosensor design with differential sensing to eliminate common mode noise and capillary microfluidic channels for sample delivery to the thermoelectric sensor. The calorimeter has a resolution of 1.4 ± 0.2 nJ/(Hz) 1/2 utilizing a 27 junction bismuth/titanium thermopile, with a total Seebeck coefficient of 2160 μV/K. Sample is wicked to the calorimeter through a capillary channel making it suitable for monitoring blood obtained through a finger prick (<1 μL sample required). We demonstrate device performance in a model assay using catalase, achieving a threshold for hydrogen peroxide quantification of 50 μM. The potential for our device as a POC blood test for metabolic diseases is shown through the quantification of phenylalanine (Phe) in serum, an unmet necessary service in the management of Phenylketonuria (PKU). Pegylated phenylalanine ammonia-lyase (PEG-PAL) was utilized to react with Phe, but reliable detection was limited to <5 mM due to low enzymatic activity. The POC biosensor concept can be multiplexed and adapted to a large number of metabolic diseases utilizing different immobilized enzymes.
Gray, J W; Milner, P J; Edwards, E H; Daniels, J P; Khan, K S
2012-07-01
Point-of-care testing (POCT) is one of the fastest growing sectors of laboratory diagnostics. Most tests in routine use are haematology or biochemistry tests that are of low complexity. Microbiology POCT has been constrained by a lack of tests that are both accurate and of low complexity. We describe our experience of the practical issues around using more complex POCT for detection of Group B streptococci (GBS) in swabs from labouring women. We evaluated two tests for their feasibility in POCT: an optical immune assay (Biostar OIA Strep B, Inverness Medical, Princetown, NJ) and a PCR (IDI-Strep B, Cepheid, Sunnyvale, CA), which have been categorised as being of moderate and high complexity, respectively. A total of 12 unqualified midwifery assistants (MA) were trained to undertake testing on the delivery suite. A systematic approach to the introduction and management of POC testing was used. Modelling showed that the probability of test results being available within a clinically useful timescale was high. However, in the clinical setting, we found it impossible to maintain reliable availability of trained testers. Implementation of more complex POC testing is technically feasible, but it is expensive, and may be difficult to achieve in a busy delivery suite.
Analytical sensitivity of four commonly used hCG point of care devices.
Kamer, Sandy M; Foley, Kevin F; Schmidt, Robert L; Greene, Dina N
2015-04-01
Point of care (POC) hCG assays are often used to rule-out pregnancy and therefore diagnostic sensitivity, especially at low concentrations of hCG, is important. There are very few studies in the literature that seek to verify the claimed analytical sensitivity of hCG POC devices. The analytical sensitivity of four commonly used hCG POC devices (Alere hCG Combo Cassette, ICON 20 hCG, OSOM hCG Combo Test, and Sure-Vue Serum/Urine hCG-STAT) was challenged using urine samples (n=50) selected based on quantitative hCG concentrations. The majority of these specimens (n=40) had an hCG concentration between 20 and 200 U/L. Each specimen/device combination was reviewed by three individuals. Statistical calculations were performed using Stata 12. The analytical sensitivity of the OSOM was significantly lower inferior than that of the other POC devices. There was no significant difference in the sensitivity of the Alere, ICON 20 and Sure-Vue devices. There was no significant difference in the individual interpretation of the hCG POC results. All hCG POC devices evaluated in this study were susceptible to false negative results at low concentrations of urine hCG. Laboratorians and clinicians should be aware that there are limitations when using urine hCG POC devices to rule out early pregnancy. Copyright © 2014 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.
Garrett, Nigel; Quame-Amaglo, Justice; Samsunder, Natasha; Ngobese, Hope; Ngomane, Noluthando; Moodley, Pravikrishnen; Mlisana, Koleka; Schaafsma, Torin; Donnell, Deborah; Barnabas, Ruanne; Naidoo, Kogieleum; Abdool Karim, Salim; Celum, Connie; Drain, Paul K
2017-01-01
Introduction Achieving the Joint United Nations Programme on HIV and AIDS 90-90-90 targets requires models of HIV care that expand antiretroviral therapy (ART) coverage without overburdening health systems. Point-of-care (POC) viral load (VL) testing has the potential to efficiently monitor ART treatment, while enrolled nurses may be able to provide safe and cost-effective chronic care for stable patients with HIV. This study aims to demonstrate whether POC VL testing combined with task shifting to enrolled nurses is non-inferior and cost-effective compared with laboratory-based VL monitoring and standard HIV care. Methods and analysis The STREAM (Simplifying HIV TREAtment and Monitoring) study is an open-label, non-inferiority, randomised controlled implementation trial. HIV-positive adults, clinically stable at 6 months after ART initiation, will be recruited in a large urban clinic in South Africa. Approximately 396 participants will be randomised 1:1 to receive POC HIV VL monitoring and potential task shifting to enrolled nurses, versus laboratory VL monitoring and standard South African HIV care. Initial clinic follow-up will be 2-monthly in both arms, with VL testing at enrolment, 6 months and 12 months. At 6 months (1 year after ART initiation), stable participants in both arms will qualify for a differentiated care model involving decentralised ART pickup at community-based pharmacies. The primary outcome is retention in care and virological suppression at 12 months from enrolment. Secondary outcomes include time to appropriate entry into the decentralised ART delivery programme, costs per virologically suppressed patient and cost-effectiveness of the intervention compared with standard care. Findings will inform the scale up of VL testing and differentiated care in HIV-endemic resource-limited settings. Ethics and dissemination Ethical approval has been granted by the University of KwaZulu-Natal Biomedical Research Ethics Committee (BFC296/16) and
Long-Term Performance of Point-of-Care Hemoglobin A1c Assays
Paknikar, Sujaytha; Sarmah, Rohan; Sivaganeshan, Losika; Welke, Adam; Rizzo, Al; Larson, Kirk; Rendell, Marc
2016-01-01
Background: Point-of-care (POC) testing of HbA1c is used as a time-efficient tool to improve treatment and management planning for diabetes in the clinic setting. HbA1c values are the basis for monitoring ongoing response to treatment and to make adjustments to diabetes therapy. Yet, there is ongoing controversy as to the accuracy of POC assays. Diabetes is a lifelong disease, so comparability of results over a long period of time is needed to follow the response to treatment. Methods: We compared the Afinion™ automated boronate affinity assay and the DCA Vantage immunoassay-based POC techniques to the Tosoh G8 and Bio-Rad Variant II ion-exchange high-performance liquid chromatography (HPLC) central laboratory methods in a study lasting 3 years. College of American Pathology Survey results and American Proficiency testing were utilized to assess the external validity of the POC techniques. Results: Despite high correlations among the 4 techniques, there were significant and variable differences obtained over time. The Biorad values varied from 0.1 to 0.4% higher than the Afinion values. The DCA results were usually higher than the Afinion values, but fell below the Afinion results in the last 6 months of our study. Both POC techniques gave systematically lower values than the Tosoh measurements, and both the POC and the central laboratory measurements showed variable differences from the National Glycohemoglobin Standardization Program values over the duration of this study. Conclusions: All who rely on POC methods as well as on central laboratory measurement of HbA1c must understand the potential limitations of these assays. The assessment of diabetes blood sugar control should proceed from the evaluation of HbA1c combined with review of plasma glucose and of self-monitored blood glucose values. PMID:27113451
A Novel Quantum Dots-Based Point of Care Test for Syphilis
NASA Astrophysics Data System (ADS)
Yang, Hao; Li, Ding; He, Rong; Guo, Qin; Wang, Kan; Zhang, Xueqing; Huang, Peng; Cui, Daxiang
2010-05-01
One-step lateral flow test is recommended as the first line screening of syphilis for primary healthcare settings in developing countries. However, it generally shows low sensitivity. We describe here the development of a novel fluorescent POC (Point Of Care) test method to be used for screening for syphilis. The method was designed to combine the rapidness of lateral flow test and sensitiveness of fluorescent method. 50 syphilis-positive specimens and 50 healthy specimens conformed by Treponema pallidum particle agglutination (TPPA) were tested with Quantum Dot-labeled and colloidal gold-labeled lateral flow test strips, respectively. The results showed that both sensitivity and specificity of the quantum dots-based method reached up to 100% (95% confidence interval [CI], 91-100%), while those of the colloidal gold-based method were 82% (95% CI, 68-91%) and 100% (95% CI, 91-100%), respectively. In addition, the naked-eye detection limit of quantum dot-based method could achieve 2 ng/ml of anti-TP47 polyclonal antibodies purified by affinity chromatography with TP47 antigen, which was tenfold higher than that of colloidal gold-based method. In conclusion, the quantum dots were found to be suitable for labels of lateral flow test strip. Its ease of use, sensitiveness and low cost make it well-suited for population-based on-the-site syphilis screening.
Manchikanti, Laxmaiah; Malla, Yogesh; Wargo, Bradley W; Cash, Kimberly A; Pampati, Vidyasagar; Damron, Kim S; McManus, Carla D; Brandon, Doris E
2010-01-01
Therapeutic use, overuse, abuse, and diversion of controlled substances in managing chronic non-cancer pain continues to be an issue for physicians and patients. It has been stated that physicians, along with the public and federal, state, and local government; professional associations; and pharmaceutical companies all share responsibility for preventing abuse of controlled prescription drugs. The challenge is to eliminate or significantly curtail abuse of controlled prescription drugs while still assuring the proper treatment of those patients. A number of techniques, instruments, and tools have been described to monitor controlled substance use and abuse. Thus, multiple techniques and tools available for adherence monitoring include urine drug testing in conjunction with prescription monitoring programs and other screening tests. However, urine drug testing is associated with multiple methodological flaws. Multiple authors have provided conflicting results in relation to diagnostic accuracy with differing opinions about how to monitor adherence in a non-systematic fashion. Thus far, there have not been any studies systematically assessing the diagnostic accuracy of immunoassay with laboratory testing. A diagnostic accuracy study of urine drug testing. An interventional pain management practice, a specialty referral center, a private practice setting in the United States. To compare the information obtained by point of care (POC) or in-office urine drug testing (index test) to the information found when all drugs and analytes are tested by liquid chromatography tandem mass spectroscopy (LC/MS/MS) reference test in the same urine sample. The study is designed to include 1,000 patients with chronic pain receiving controlled substances. The primary outcome measure is the diagnostic accuracy. Patients will be tested for various controlled substances, including opioids, benzodiazepines, and illicit drugs. The diagnostic accuracy study is performed utilizing the
Pastakia, Sonak D; Njuguna, Benson; Onyango, Beryl Ajwang'; Washington, Sierra; Christoffersen-Deb, Astrid; Kosgei, Wycliffe K; Saravanan, Ponnusamy
2017-07-14
Early diagnosis of gestational diabetes mellitus (GDM) is crucial to prevent short term delivery risks and long term effects such as cardiovascular and metabolic diseases in the mother and infant. Diagnosing GDM in Sub-Saharan Africa (SSA) however, remains sub-optimal due to associated logistical and cost barriers for resource-constrained populations. A cost-effective strategy to screen for GDM in such settings are therefore urgently required. We conducted this study to determine the prevalence of gestational diabetes mellitus (GDM) and assess utility of various GDM point of care (POC) screening strategies in a resource-constrained setting. Eligible women aged ≥18 years, and between 24 and 32 weeks of a singleton pregnancy, prospectively underwent testing over two days. On day 1, a POC 1-h 50 g glucose challenge test (GCT) and a POC glycated hemoglobin (HbA1c) was assessed. On day 2, fasting blood glucose, 1-h and 2-h 75 g oral glucose tolerance test (OGTT) were determined using both venous and POC tests, along with a venous HbA1c. The International Association of Diabetes in Pregnancy Study Group (IADPSG) criteria was used to diagnose GDM. GDM prevalence was reported with 95% confidence interval (CI). Specificity, sensitivity, positive predictive value, and negative predictive value of the various POC testing strategies were determined using IADPSG testing as the standard reference. Six hundred-sixteen eligible women completed testing procedures. GDM was diagnosed in 18 women, a prevalence of 2.9% (95% CI, 1.57% - 4.23%). Compared to IADPSG testing, POC IADPSG had a sensitivity and specificity of 55.6% and 90.6% respectively while that of POC 1-h 50 g GCT (using a diagnostic cut-off of ≥7.2 mmol/L [129.6 mg/dL]) was 55.6% and 63.9%. All other POC tests assessed showed poor sensitivity. POC screening strategies though feasible, showed poor sensitivity for GDM detection in our resource-constrained population of low GDM prevalence. Studies to identify
van Doorn, H Rogier; Kinh, Nguyen van; Tuan, Ha Manh; Tuan, Tran Anh; Minh, Ngo Ngoc Quang; Bryant, Juliet E; Hang, Vu thi Ty; Uyen, Le thi Tham; Thinh, Le Quoc; Anh, Tran thi Ngoc; Lan, Nguyen Phu Huong; Trung, Nguyen Vu; Taylor, Walter; Merson, Laura; Wertheim, Heiman F L; Farrar, Jeremy; Wolbers, Marcel; Chau, Nguyen van Vinh; de Jong, Menno D
2012-05-01
Point-of-care (POC) diagnostic tests for influenza can considerably shorten the time to clinical decision making. An investigational POC test based on a multiplexed immunoassay was developed by Meso Scale Diagnostics, LLC (MSD), with the objective to make a more sensitive rapid test that can also subtype influenza A viruses (1977 H1, H3, and H5). Between February and November 2010, we conducted a prospective multicenter study at four hospitals in Vietnam and compared the performance of this test to that of the WHO/CDC real-time reverse transcriptase PCR (RT-PCR) on nasal and throat swab specimens from patients presenting with influenza-like illness. Five hundred sixty-three adults and children with a median age of 25 months were enrolled. Sensitivity and specificity of the test with combined results from nasal and throat swab samples were 74.0% (131/177) and 99.7% (351/352), respectively, compared to RT-PCR. The POC test was as sensitive for influenza virus B as for influenza virus A (74.4% [64/86] versus 73.6% [67/91]). The positivity rate was associated with lower cycle threshold values (a marker for higher viral loads), sample type (73.6% for nasal swab versus 52.4% for throat swab), and younger age. A total of 210 (18.7%) out of 1,126 MSD tests failed, and for 34 (6%) of patients, both test samples failed (these were excluded from the performance analysis). Subtyping could be assessed only for influenza virus A/H3N2, as 1977 H1N1 was not circulating at the time and no H5N1-infected patients were enrolled, and was successful only in 9/54 patients infected with H3 influenza virus who had a positive POC test result for influenza virus A. This novel POC test provided highly sensitive detection of influenza viruses A and B compared to the reported sensitivities of other rapid tests. However, 18.7% of tests failed for technical reasons and subtyping for H3 was poor. Drawbacks to the technology include the requirement for a dedicated reader instrument and the need for
Cortina, María E; Melli, Luciano J; Roberti, Mariano; Mass, Mijal; Longinotti, Gloria; Tropea, Salvador; Lloret, Paulina; Serantes, Diego A Rey; Salomón, Francisco; Lloret, Matías; Caillava, Ana J; Restuccia, Sabrina; Altcheh, Jaime; Buscaglia, Carlos A; Malatto, Laura; Ugalde, Juan E; Fraigi, Liliana; Moina, Carlos; Ybarra, Gabriel; Ciocchini, Andrés E; Comerci, Diego J
2016-06-15
Access to appropriate diagnostic tools is an essential component in the evaluation and improvement of global health. Additionally, timely detection of infectious agents is critical in early diagnosis and treatment of infectious diseases. Conventional pathogen detection methods such as culturing, enzyme linked immunosorbent assay (ELISA) or polymerase chain reaction (PCR) require long assay times, and complex and expensive instruments making them not adaptable to point-of-care (PoC) needs at resource-constrained places and primary care settings. Therefore, there is an unmet need to develop portable, simple, rapid, and accurate methods for PoC detection of infections. Here, we present the development and validation of a portable, robust and inexpensive electrochemical magnetic microbeads-based biosensor (EMBIA) platform for PoC serodiagnosis of infectious diseases caused by different types of microorganisms (parasitic protozoa, bacteria and viruses). We demonstrate the potential use of the EMBIA platform for in situ diagnosis of human (Chagas disease and human brucellosis) and animal (bovine brucellosis and foot-and-mouth disease) infections clearly differentiating infected from non-infected individuals or animals. For Chagas disease, a more extensive validation of the test was performed showing that the EMBIA platform displayed an excellent diagnostic performance almost indistinguishable, in terms of specificity and sensitivity, from a fluorescent immunomagnetic assay and the conventional ELISA using the same combination of antigens. This platform technology could potentially be applicable to diagnose other infectious and non-infectious diseases as well as detection and/or quantification of biomarkers at the POC and primary care settings. Copyright © 2016 Elsevier B.V. All rights reserved.
Large-scale performance evaluation of Accu-Chek inform II point-of-care glucose meters.
Jeong, Tae-Dong; Cho, Eun-Jung; Ko, Dae-Hyun; Lee, Woochang; Chun, Sail; Hong, Ki-Sook; Min, Won-Ki
2016-12-01
The aim of this study was to report the experience of large-scale performance evaluation of 238 Accu-Chek Inform II point-of-care (POC) glucose meters in a single medical setting. The repeatability of 238 POC devices, the within-site imprecision of 12 devices, and the linearity of 49 devices were evaluated using glucose control solutions. The glucose results of 24 POC devices and central laboratory were compared using patient samples. Mean concentration of control solutions was 2.39 mmol/L for Level 1 and 16.52 mmol/L for Level 2. The pooled repeatability coefficient of variation (CV) of the 238 devices was 2.0% for Level 1 and 1.6% for Level 2. The pooled within-site imprecision CV and reproducibility CV of the 12 devices were 2.7% and 2.7% for Level 1, and 1.9%, and 1.9% for Level 2, respectively. The test results of all 49 devices were linear within analytical measurement range from 1.55-31.02 mmol/L. The correlation coefficient for individual POC devices ranged from 0.9967-0.9985. The total correlation coefficient for the 24 devices was 0.998. The Accu-Chek Inform II POC blood glucose meters performed well in terms of precision, linearity, and correlation evaluations. Consensus guidelines for the large-scale performance evaluations of POC devices are required.
Pierce, Mark C; Weigum, Shannon E; Jaslove, Jacob M; Richards-Kortum, Rebecca; Tkaczyk, Tomasz S
2014-01-01
One of the key elements in point-of-care (POC) diagnostic test instrumentation is the optical system required for signal detection and/or imaging. Many tests which use fluorescence, absorbance, or colorimetric optical signals are under development for management of infectious diseases in resource limited settings, where the overall size and cost of the device is of critical importance. At present, high-performance lenses are expensive to fabricate and difficult to obtain commercially, presenting barriers for developers of in vitro POC tests or microscopic image-based diagnostics. We recently described a compact "hybrid" objective lens incorporating both glass and plastic optical elements, with a numerical aperture of 1.0 and field-of-view of 250 μm. This design concept may potentially enable mass-production of high-performance, low-cost optical systems which can be easily incorporated in the readout path of existing and emerging POC diagnostic assays. In this paper, we evaluate the biological imaging performance of these lens systems in three broad POC diagnostic application areas; (1) bright field microscopy of histopathology slides, (2) cytologic examination of blood smears, and (3) immunofluorescence imaging. We also break down the fabrication costs and draw comparisons with other miniature optical systems. The hybrid lenses provided images with quality comparable to conventional microscopy, enabling examination of neoplastic pathology and infectious parasites including malaria and cryptosporidium. We describe how these components can be produced at below $10 per unit in full-scale production quantities, making these systems well suited for use within POC diagnostic instrumentation.
Dorward, Jienchi; Garrett, Nigel; Quame-Amaglo, Justice; Samsunder, Natasha; Ngobese, Hope; Ngomane, Noluthando; Moodley, Pravikrishnen; Mlisana, Koleka; Schaafsma, Torin; Donnell, Deborah; Barnabas, Ruanne; Naidoo, Kogieleum; Abdool Karim, Salim; Celum, Connie; Drain, Paul K
2017-09-27
Achieving the Joint United Nations Programme on HIV and AIDS 90-90-90 targets requires models of HIV care that expand antiretroviral therapy (ART) coverage without overburdening health systems. Point-of-care (POC) viral load (VL) testing has the potential to efficiently monitor ART treatment, while enrolled nurses may be able to provide safe and cost-effective chronic care for stable patients with HIV. This study aims to demonstrate whether POC VL testing combined with task shifting to enrolled nurses is non-inferior and cost-effective compared with laboratory-based VL monitoring and standard HIV care. The STREAM (Simplifying HIV TREAtment and Monitoring) study is an open-label, non-inferiority, randomised controlled implementation trial. HIV-positive adults, clinically stable at 6 months after ART initiation, will be recruited in a large urban clinic in South Africa. Approximately 396 participants will be randomised 1:1 to receive POC HIV VL monitoring and potential task shifting to enrolled nurses, versus laboratory VL monitoring and standard South African HIV care. Initial clinic follow-up will be 2-monthly in both arms, with VL testing at enrolment, 6 months and 12 months. At 6 months (1 year after ART initiation), stable participants in both arms will qualify for a differentiated care model involving decentralised ART pickup at community-based pharmacies. The primary outcome is retention in care and virological suppression at 12 months from enrolment. Secondary outcomes include time to appropriate entry into the decentralised ART delivery programme, costs per virologically suppressed patient and cost-effectiveness of the intervention compared with standard care. Findings will inform the scale up of VL testing and differentiated care in HIV-endemic resource-limited settings. Ethical approval has been granted by the University of KwaZulu-Natal Biomedical Research Ethics Committee (BFC296/16) and University of Washington Institutional Review Board (STUDY
Performance evaluation of the microINR® point-of-care INR-testing system.
Joubert, J; van Zyl, M C; Raubenheimer, J
2018-04-01
Point-of-care International Normalised Ratio (INR) testing is used frequently. We evaluated the microINR ® POC system for accuracy, precision and measurement repeatability, and investigated instrument and test chip variability and error rates. Venous blood INRs of 210 patients on warfarin were obtained with Thromborel ® S on the Sysmex CS-2100i ® analyser and compared with capillary blood microINR ® values. Precision was assessed using control materials. Measurement repeatability was calculated on 51 duplicate finger-prick INRs. Triplicate finger-prick INRs using three different instruments (30 patients) and three different test chip lots (29 patients) were used to evaluate instrument and test chip variability. Linear regression analysis of microINR ® and Sysmex CS2100i ® values showed a correlation coefficient of 0.96 (P < .0001) and a positive proportional bias of 4.4%. Dosage concordance was 93.8% and clinical agreement 95.7%. All acceptance criteria based on ISO standard 17593:2007 system accuracy requirements were met. Control material coefficients of variation (CV) varied from 6.2% to 16.7%. The capillary blood measurement repeatability CV was 7.5%. No significant instrument (P = .93) or test chip (P = .81) variability was found, and the error rate was low (2.8%). The microINR ® instrument is accurate and precise for monitoring warfarin therapy. © 2017 John Wiley & Sons Ltd.
Adapting a large database of point of care summarized guidelines: a process description.
Delvaux, Nicolas; Van de Velde, Stijn; Aertgeerts, Bert; Goossens, Martine; Fauquert, Benjamin; Kunnamo, Ilka; Van Royen, Paul
2017-02-01
Questions posed at the point of care (POC) can be answered using POC summarized guidelines. To implement a national POC information resource, we subscribed to a large database of POC summarized guidelines to complement locally available guidelines. Our challenge was in developing a sustainable strategy for adapting almost 1000 summarized guidelines. The aim of this paper was to describe our process for adapting a database of POC summarized guidelines. An adaptation process based on the ADAPTE framework was tailored to be used by a heterogeneous group of participants. Guidelines were assessed on content and on applicability to the Belgian context. To improve efficiency, we chose to first aim our efforts towards those guidelines most important to primary care doctors. Over a period of 3 years, we screened about 80% of 1000 international summarized guidelines. For those guidelines identified as most important for primary care doctors, we noted that in about half of the cases, remarks were made concerning content. On the other hand, at least two-thirds of all screened guidelines required no changes when evaluating their local usability. Adapting a large body of POC summarized guidelines using a formal adaptation process is possible, even when faced with limited resources. This can be done by creating an efficient and collaborative effort and ensuring user-friendly procedures. Our experiences show that even though in most cases guidelines can be adopted without adaptations, careful review of guidelines developed in a different context remains necessary. Streamlining international efforts in adapting international POC information resources and adopting similar adaptation processes may lessen duplication efforts and prove more cost-effective. © 2015 The Authors. Journal of Evaluation in Clinical Practice published by John Wiley & Sons, Ltd.
What Can We Learn From Point-of-Care Blood Glucose Values Deleted and Repeated by Nurses?
Corl, Dawn; Yin, Tom; Ulibarri, May; Lien, Heather; Tylee, Tracy; Chao, Jing; Wisse, Brent E
2018-03-01
Hospitals rely on point-of-care (POC) blood glucose (BG) values to guide important decisions related to insulin administration and glycemic control. Evaluation of POC BG in hospitalized patients is associated with measurement and operator errors. Based on a previous quality improvement (QI) project we introduced an option for operators to delete and repeat POC BG values suspected as erroneous. The current project evaluated our experience with deleted POC BG values over a 2-year period. A retrospective QI project included all patients hospitalized at two regional academic medical centers in the Pacific Northwest during 2014 and 2015. Laboratory Medicine POC BG data were reviewed to evaluate all inpatient episodes of deleted and repeated POC BG. Inpatient operators choose to delete and repeat only 0.8% of all POC BG tests. Hypoglycemic and extreme hyperglycemic BG values are more likely to be deleted and repeated. Of initial values <40 mg/dL, 58% of deleted values (18% of all values) are errors. Of values >400 mg/dL, 40% of deleted values (5% of all values) are errors. Not all repeated POC BG values are first deleted. Optimal use of the option to delete and repeat POC BG values <40 mg/dL could decrease reported rates of severe hypoglycemia by as much as 40%. This project demonstrates that operators are frequently able to identify POC BG values that are measurement/operator errors. Eliminating these errors significantly reduces documented rates of severe hypoglycemia and hyperglycemia, and has the potential to improve patient safety.
Resident training in point-of-care testing.
Campbell, Sheldon; Howanitz, Peter J
2007-06-01
Although central laboratory testing has been the norm for the last few decades and point-of-care testing (POCT) is considered an emerging area, physicians were performing POCT long before the existence of central laboratory testing. As medical directors of POCT programs, pathologists need the basic knowledge and skills associated with directing laboratory-based testing programs as well as additional knowledge and skills about testing at the point of care. Although the essential elements of quality testing are the same for laboratory-based and POCT, the enormous variety of settings, technologies, and workers involved present unique challenges.
Westman, Mark E; Malik, Richard; Hall, Evelyn; Sheehy, Paul A; Norris, Jacqueline M
2017-02-01
Feline leukaemia virus (FeLV) can be a challenging infection to diagnose due to a complex feline host-pathogen relationship and occasionally unreliable test results. This study compared the accuracy of three point-of-care (PoC) FeLV p27 antigen test kits commonly used in Australia and available commercially worldwide (SNAP FIV/FeLV Combo, Witness FeLV/FIV and Anigen Rapid FIV/FeLV), using detection of FeLV provirus by an in-house real-time polymerase chain reaction (qPCR) assay as the diagnostic gold standard. Blood (n=563) and saliva (n=419) specimens were collected from a population of cats determined to include 491 FeLV-uninfected and 72 FeLV-infected individuals (45 progressive infections [p27 and qPCR positive], 27 regressive infections [p27 negative, qPCR positive]). Sensitivity and specificity using whole blood was 63% and 94% for SNAP Combo, 57% and 98% for Witness, and 57% and 98% for Anigen Rapid, respectively. SNAP Combo had a significantly lower specificity using blood compared to the other two kits (P=0.004 compared to Witness, P=0.007 compared to Anigen Rapid). False-positive test results occurred with all three kits using blood, and although using any two kits in parallel increased specificity, no combination of kits completely eliminated the occurrence of false-positive results. We therefore recommend FeLV proviral PCR testing for any cat that tests positive with a PoC FeLV antigen kit, as well as for any cat that has been potentially exposed to FeLV but tests negative with a FeLV antigen kit, before final assignment of FeLV status can be made with confidence. For saliva testing, sensitivity and specificity was 54% and 100%, respectively, for all three test kits. The reduced sensitivity of saliva testing compared to blood testing, although not statistically significant, suggests saliva testing with the current generation of PoC FeLV antigen kits is unsuitable for screening large populations of cats, such as in shelters. Copyright © 2016 Elsevier
Wang, ShuQi; Lifson, Mark A.; Inci, Fatih; Liang, Li-Guo; Sheng, Ye-Feng; Demirci, Utkan
2016-01-01
The striking prevalence of HIV, TB and malaria, as well as outbreaks of emerging infectious diseases, such as influenza A (H7N9), Ebola and MERS, poses great challenges for patient care in resource-limited settings (RLS). However, advanced diagnostic technologies cannot be implemented in RLS largely due to economic constraints. Simple and inexpensive point-of-care (POC) diagnostics, which rely less on environmental context and operator training, have thus been extensively studied to achieve early diagnosis and treatment monitoring in non-laboratory settings. Despite great input from material science, biomedical engineering and nanotechnology for developing POC diagnostics, significant technical challenges are yet to be overcome. Summarized here are the technical challenges associated with POC diagnostics from a RLS perspective and the latest advances in addressing these challenges are reviewed. PMID:26777725
Design of point-of-care (POC) microfluidic medical diagnostic devices
NASA Astrophysics Data System (ADS)
Leary, James F.
2018-02-01
Design of inexpensive and portable hand-held microfluidic flow/image cytometry devices for initial medical diagnostics at the point of initial patient contact by emergency medical personnel in the field requires careful design in terms of power/weight requirements to allow for realistic portability as a hand-held, point-of-care medical diagnostics device. True portability also requires small micro-pumps for high-throughput capability. Weight/power requirements dictate use of super-bright LEDs and very small silicon photodiodes or nanophotonic sensors that can be powered by batteries. Signal-to-noise characteristics can be greatly improved by appropriately pulsing the LED excitation sources and sampling and subtracting noise in between excitation pulses. The requirements for basic computing, imaging, GPS and basic telecommunications can be simultaneously met by use of smartphone technologies, which become part of the overall device. Software for a user-interface system, limited real-time computing, real-time imaging, and offline data analysis can be accomplished through multi-platform software development systems that are well-suited to a variety of currently available cellphone technologies which already contain all of these capabilities. Microfluidic cytometry requires judicious use of small sample volumes and appropriate statistical sampling by microfluidic cytometry or imaging for adequate statistical significance to permit real-time (typically < 15 minutes) medical decisions for patients at the physician's office or real-time decision making in the field. One or two drops of blood obtained by pin-prick should be able to provide statistically meaningful results for use in making real-time medical decisions without the need for blood fractionation, which is not realistic in the field.
Product qualification: a barrier to point-of-care microfluidic-based diagnostics?
Tantra, Ratna; van Heeren, Henne
2013-06-21
One of the most exciting applications of microfluidics-based diagnostics is its potential use in next generation point-of-care (POC) devices. Many prototypes are already in existence, but, as of yet, few have achieved commercialisation. In this article, we consider the issue surrounding product qualification as a potential barrier to market success. The study discusses, in the context of POC microfluidics-based diagnostics, what the generic issues are and potential solutions. Our findings underline the need for a community-based effort that is necessary to speed up the product qualification process.
Analytical validation of a new point-of-care assay for serum amyloid A in horses.
Schwartz, D; Pusterla, N; Jacobsen, S; Christopher, M M
2018-01-17
Serum amyloid A (SAA) is a major acute phase protein in horses. A new point-of-care (POC) test for SAA (Stablelab) is available, but studies evaluating its analytical accuracy are lacking. To evaluate the analytical performance of the SAA POC test by 1) determining linearity and precision, 2) comparing results in whole blood with those in serum or plasma, and 3) comparing POC results with those obtained using a previously validated turbidimetric immunoassay (TIA). Assay validation. Analytical validation of the POC test was done in accordance with American Society of Veterinary Clinical Pathology guidelines using residual equine serum/plasma and whole blood samples from the Clinical Pathology Laboratory at the University of California-Davis. A TIA was used as the reference method. We also evaluated the effect of haematocrit (HCT). The POC test was linear for SAA concentrations of up to at least 1000 μg/mL (r = 0.991). Intra-assay CVs were 13, 18 and 15% at high (782 μg/mL), intermediate (116 μg/mL) and low (64 μg/mL) concentrations. Inter-assay (inter-batch) CVs were 45, 14 and 15% at high (1372 μg/mL), intermediate (140 μg/mL) and low (56 μg/mL) concentrations. SAA results in whole blood were significantly lower than those in serum/plasma (P = 0.0002), but were positively correlated (r = 0.908) and not affected by HCT (P = 0.261); proportional negative bias was observed in samples with SAA>500 μg/mL. The difference between methods exceeded the 95% confidence interval of the combined imprecision of both methods (15%). Analytical validation could not be performed in whole blood, the sample most likely to be used stall side. The POC test has acceptable accuracy and precision in equine serum/plasma with SAA concentrations of up to at least 1000 μg/mL. Low inter-batch precision at high concentrations may affect serial measurements, and the use of the same test batch and sample type (serum/plasma or whole blood) is recommended. Comparison of results between the
Point of care investigations in pediatric care to improve health care in rural areas.
Walia, Kamini
2013-07-01
The good quality laboratory services in developing countries are often limited to major urban centers. As a result, many commercially available high-quality diagnostic tests for infectious diseases are neither accessible nor affordable to patients in the rural areas. Health facilities in rural areas are compromised and this limits the usability and performance of the best medical diagnostic technologies in rural areas as they are designed for air-conditioned laboratories, refrigerated storage of chemicals, a constant supply of calibrators and reagents, stable electrical power, highly trained personnel and rapid transportation of samples. The advent of new technologies have allowed miniaturization and integration of complex functions, which has made it possible for sophisticated diagnostic tools to move out of the developed-world laboratory in the form of a "point of care"(POC) tests. Many diagnostic tests are being developed using these platforms. However, the challenge is to develop diagnostics which are inexpensive, rugged and well suited to the medical and social contexts of the developing world and do not compromise on accuracy and reliability. The already available POC tests which are reliable and affordable, like for HIV infection, malaria, syphilis, and some neglected tropical diseases, and POC tests being developed for other diseases if correctly used and effectively regulated after rigorous evaluation, have the potential to make a difference in clinical management and improve surveillance. In order to use these tests effectively they would need to be supported by technically competent manpower, availability of good-quality reagents, and healthcare providers who value and are able to interpret laboratory results to guide treatment; and a system for timely communication between the laboratory and the healthcare provider. Strengthening the laboratories at the rural level can enable utilization of these diagnostics for improving the diagnosis and management of
Stavelin, Anne; Sandberg, Sverre
2018-05-16
Noklus is a non-profit quality improvement organization that focuses to improve all elements in the total testing process. The aim is to ensure that all medical laboratory examinations are ordered, performed and interpreted correctly and in accordance with the patients' needs for investigation, treatment and follow-up. For 25 years, Noklus has focused on point-of-care (POC) testing in primary healthcare laboratories and has more than 3100 voluntary participants. The Noklus quality system uses different tools to obtain harmonization and improvement: (1) external quality assessment for the pre-examination, examination and postexamination phase to monitor the harmonization process and to identify areas that need improvement and harmonization, (2) manufacturer-independent evaluations of the analytical quality and user-friendliness of POC instruments and (3) close interactions and follow-up of the participants through site visits, courses, training and guidance. Noklus also recommends which tests that should be performed in the different facilities like general practitioner offices, nursing homes, home care, etc. About 400 courses with more than 6000 delegates are organized annually. In 2017, more than 21,000 e-learning programs were completed.
The Accuracy of Point-of-Care Glucose Measurements
Rebel, Annette; Rice, Mark A.; Fahy, Brenda G.
2012-01-01
Control of blood glucose (BG) in an acceptable range is a major therapy target for diabetes patients in both the hospital and outpatient environments. This review focuses on the state of point-of-care (POC) glucose monitoring and the accuracy of the measurement devices. The accuracy of the POC glucose monitor depends on device methodology and other factors, including sample source and collection and patient characteristics. Patient parameters capable of influencing measurements include variations in pH, blood oxygen, hematocrit, changes in microcirculation, and vasopressor therapy. These elements alone or when combined can significantly impact BG measurement accuracy with POC glucose monitoring devices (POCGMDs). In general, currently available POCGMDs exhibit the greatest accuracy within the range of physiological glucose levels but become less reliable at the lower and higher ranges of BG levels. This issue raises serious safety concerns and the importance of understanding the limitations of POCGMDs. This review will discuss potential interferences and shortcomings of the current POCGMDs and stress when these may impact the reliability of POCGMDs for clinical decision-making. PMID:22538154
The Value of Clinical Needs Assessments for Point-of-Care Diagnostics
Weigl, Bernhard H.; Gaydos, Charlotte A.; Kost, Gerald; Beyette, Fred R.; Sabourin, Stephanie; Rompalo, Anne; de los Santos, Tala; McMullan, Jason T.; Haller, John
2013-01-01
Most entrepreneurial ventures fail long before the core technology can be brought to the marketplace because of disconnects in performance and usability measures such as accuracy, cost, complexity, assay stability, and time requirements between technology developers’ specifications and needs of the end-users. By going through a clinical needs assessment (CNA) process, developers will gain vital information and a clear focus that will help minimize the risks associated with the development of new technologies available for use within the health care system. This article summarizes best practices of the principal investigators of the National Institute of Biomedical Imaging and Bioengineering point-of-care (POC) centers within the National Institute of Biomedical Imaging and Bioengineering POC Technologies Research Network. Clinical needs assessments are particularly important for product development areas that do not sufficiently benefit from traditional market research, such as grant-funded research and development, new product lines using cutting-edge technologies developed in start-up companies, and products developed through product development partnerships for low-resource settings. The objectives of this article were to (1) highlight the importance of CNAs for development of POC devices, (2) discuss methods applied by POC Technologies Research Network for assessing clinical needs, and (3) provide a road map for future CNAs. PMID:23935405
Cao, D; Maynard, S; Mitchell, A M; Kerns, W P; Beuhler, M
2014-07-01
Nitromethane interferes with Jaffé measurements of creatinine, potentially mimicking acute kidney injury. We determined the proportional contribution of nitromethane in blood samples to creatinine measured by the Jaffé colorimetric and the point-of-care (POC) reactions and determined whether the difference can reliably estimate the concentration of nitromethane. Additionally, we determined whether the presence of nitromethane interferes with anion/osmolal gaps and ascertained the stability of nitromethane in serum after 7 days. Nitromethane was added to whole blood from four healthy volunteers to achieve concentrations of 0, 0.25, 0.5, 1, and 2 mmol/L. The following tests were performed: creatinine (Jaffé and POC), electrolytes (associated with Jaffé and POC), osmolality and nitromethane concentration (gas chromatography [GC]). Remaining samples were refrigerated and reanalyzed using GC at 7 days. Anion and osmolal gaps were calculated. Proportional recovery and degradation of nitromethane were measured using GC. Data were analyzed for agreement with single-factor ANOVA (p = 0.05). Mean creatinine for POC and Jaff methods were 0.93 vs. 0.76 mg/dL, respectively. Jaff creatinine concentrations increased linearly with increasing nitromethane concentrations (R(2) = 1, p = 0.01): measured creatinine (mg/dL) = 7.1*nitromethane (mmol/L) = 0.79. POC creatinine remained unchanged across the range of nitromethane concentrations (p = 0.99). Anion and osmolal gaps also remained unchanged. Nitromethane was reliably identified in all sample concentrations using GC on Day 0. Detection of 0.25 mmol/L nitromethane was not consistently recovered on Day 7. Nitromethane degradation was most pronounced at 2 mmol/L concentrations (81% recovery). Nitromethane alters apparent concentration of creatinine using the Jaffé reaction in a linear fashion but not when using the POC reaction. Measured difference between Jaffé and POC creatinine may identify the presence and estimate
Luo, Xiaoteng; Hsing, I-Ming
2009-10-01
Nucleic acid based analysis provides accurate differentiation among closely affiliated species and this species- and sequence-specific detection technique would be particularly useful for point-of-care (POC) testing for prevention and early detection of highly infectious and damaging diseases. Electrochemical (EC) detection and polymerase chain reaction (PCR) are two indispensable steps, in our view, in a nucleic acid based point-of-care testing device as the former, in comparison with the fluorescence counterpart, provides inherent advantages of detection sensitivity, device miniaturization and operation simplicity, and the latter offers an effective way to boost the amount of targets to a detectable quantity. In this mini-review, we will highlight some of the interesting investigations using the combined EC detection and PCR amplification approaches for end-point detection and real-time monitoring. The promise of current approaches and the direction for future investigations will be discussed. It would be our view that the synergistic effect of the combined EC-PCR steps in a portable device provides a promising detection technology platform that will be ready for point-of-care applications in the near future.
Field evaluation of a prototype paper-based point-of-care fingerstick transaminase test.
Pollock, Nira R; McGray, Sarah; Colby, Donn J; Noubary, Farzad; Nguyen, Huyen; Nguyen, The Anh; Khormaee, Sariah; Jain, Sidhartha; Hawkins, Kenneth; Kumar, Shailendra; Rolland, Jason P; Beattie, Patrick D; Chau, Nguyen V; Quang, Vo M; Barfield, Cori; Tietje, Kathy; Steele, Matt; Weigl, Bernhard H
2013-01-01
Monitoring for drug-induced liver injury (DILI) via serial transaminase measurements in patients on potentially hepatotoxic medications (e.g., for HIV and tuberculosis) is routine in resource-rich nations, but often unavailable in resource-limited settings. Towards enabling universal access to affordable point-of-care (POC) screening for DILI, we have performed the first field evaluation of a paper-based, microfluidic fingerstick test for rapid, semi-quantitative, visual measurement of blood alanine aminotransferase (ALT). Our objectives were to assess operational feasibility, inter-operator variability, lot variability, device failure rate, and accuracy, to inform device modification for further field testing. The paper-based ALT test was performed at POC on fingerstick samples from 600 outpatients receiving HIV treatment in Vietnam. Results, read independently by two clinic nurses, were compared with gold-standard automated (Roche Cobas) results from venipuncture samples obtained in parallel. Two device lots were used sequentially. We demonstrated high inter-operator agreement, with 96.3% (95% C.I., 94.3-97.7%) agreement in placing visual results into clinically-defined "bins" (<3x, 3-5x, and >5x upper limit of normal), >90% agreement in validity determination, and intraclass correlation coefficient of 0.89 (95% C.I., 0.87-0.91). Lot variability was observed in % invalids due to hemolysis (21.1% for Lot 1, 1.6% for Lot 2) and correlated with lots of incorporated plasma separation membranes. Invalid rates <1% were observed for all other device controls. Overall bin placement accuracy for the two readers was 84% (84.3%/83.6%). Our findings of extremely high inter-operator agreement for visual reading-obtained in a target clinical environment, as performed by local practitioners-indicate that the device operation and reading process is feasible and reproducible. Bin placement accuracy and lot-to-lot variability data identified specific targets for device
Point-of-care D-dimer testing in emergency departments.
Marquardt, Udo; Apau, Daniel
2015-09-01
Overcrowding and prolonged patient stays in emergency departments (EDs) affect patients' experiences and outcomes, and increase healthcare costs. One way of addressing these problems is through using point-of-care blood tests, laboratory testing undertaken near patient locations with rapidly available results. D-dimer tests are used to exclude venous thromboembolism (VTE), a common presentation in EDs, in low-risk patients. However, data on the effects of point-of-care D-dimer testing in EDs and other urgent care settings are scarce. This article reports the results of a literature review that examined the benefits to patients of point-of-care D-dimer testing in terms of reduced turnaround times (time to results), and time to diagnosis, discharge or referral. It also considers the benefits to organisations in relation to reduced ED crowding and increased cost effectiveness. The review concludes that undertaking point-of-care D-dimer tests, combined with pre-test probability scores, can be a quick and safe way of ruling out VTE and improving patients' experience.
Huddy, Jeremy R; Ni, Melody; Mavroveli, Stella; Barlow, James; Williams, Doris-Ann; Hanna, George B
2015-07-10
Point-of-care in vitro diagnostics (POC-IVD) are increasingly becoming widespread as an acceptable means of providing rapid diagnostic results to facilitate decision-making in many clinical pathways. Evidence in utility, usability and cost-effectiveness is currently provided in a fragmented and detached manner that is fraught with methodological challenges given the disruptive nature these tests have on the clinical pathway. The Point-of-care Key Evidence Tool (POCKET) checklist aims to provide an integrated evidence-based framework that incorporates all required evidence to guide the evaluation of POC-IVD to meet the needs of policy and decisionmakers in the National Health Service (NHS). A multimethod approach will be applied in order to develop the POCKET. A thorough literature review has formed the basis of a robust Delphi process and validation study. Semistructured interviews are being undertaken with POC-IVD stakeholders, including industry, regulators, commissioners, clinicians and patients to understand what evidence is required to facilitate decision-making. Emergent themes will be translated into a series of statements to form a survey questionnaire that aims to reach a consensus in each stakeholder group to what needs to be included in the tool. Results will be presented to a workshop to discuss the statements brought forward and the optimal format for the tool. Once assembled, the tool will be field-tested through case studies to ensure validity and usability and inform refinement, if required. The final version will be published online with a call for comments. Limitations include unpredictable sample representation, development of compromise position rather than consensus, and absence of blinding in validation exercise. The Imperial College Joint Research Compliance Office and the Imperial College Hospitals NHS Trust R&D department have approved the protocol. The checklist tool will be disseminated through a PhD thesis, a website, peer
Point-of-care ultrasound diagnosis and treatment of posterior shoulder dislocation.
Beck, Sierra; Chilstrom, Mikaela
2013-02-01
Acute traumatic posterior shoulder dislocations are rare. The diagnosis is often missed or delayed, as radiologic abnormalities can be subtle. We report a case of a 37-year-old man who presented to the emergency department with severe right shoulder pain and inability to move his arm after a motor vehicle collision. Based on examination, he was initially thought to have an anterior dislocation; however, point-of-care (POC) ultrasound clearly demonstrated a posterior shoulder dislocation. Real-time ultrasound-guided intra-articular local anesthetic injection facilitated closed reduction in the emergency department without procedural sedation, and POC ultrasound confirmed successful reduction at the bedside after the procedure. This case demonstrates that POC ultrasound can be a useful diagnostic tool in the rapid assessment and treatment for patients with suspected posterior shoulder dislocation. Copyright © 2013 Elsevier Inc. All rights reserved.
Estill, Janne; Egger, Matthias; Blaser, Nello; Vizcaya, Luisa Salazar; Garone, Daniela; Wood, Robin; Campbell, Jennifer; Hallett, Timothy B; Keiser, Olivia
2013-06-01
Monitoring of HIV viral load in patients on combination antiretroviral therapy (ART) is not generally available in resource-limited settings. We examined the cost-effectiveness of qualitative point-of-care viral load tests (POC-VL) in sub-Saharan Africa. Mathematical model based on longitudinal data from the Gugulethu and Khayelitsha township ART programmes in Cape Town, South Africa. Cohorts of patients on ART monitored by POC-VL, CD4 cell count or clinically were simulated. Scenario A considered the more accurate detection of treatment failure with POC-VL only, and scenario B also considered the effect on HIV transmission. Scenario C further assumed that the risk of virologic failure is halved with POC-VL due to improved adherence. We estimated the change in costs per quality-adjusted life-year gained (incremental cost-effectiveness ratios, ICERs) of POC-VL compared with CD4 and clinical monitoring. POC-VL tests with detection limits less than 1000 copies/ml increased costs due to unnecessary switches to second-line ART, without improving survival. Assuming POC-VL unit costs between US$5 and US$20 and detection limits between 1000 and 10,000 copies/ml, the ICER of POC-VL was US$4010-US$9230 compared with clinical and US$5960-US$25540 compared with CD4 cell count monitoring. In Scenario B, the corresponding ICERs were US$2450-US$5830 and US$2230-US$10380. In Scenario C, the ICER ranged between US$960 and US$2500 compared with clinical monitoring and between cost-saving and US$2460 compared with CD4 monitoring. The cost-effectiveness of POC-VL for monitoring ART is improved by a higher detection limit, by taking the reduction in new HIV infections into account and assuming that failure of first-line ART is reduced due to targeted adherence counselling.
Mashamba-Thompson, Tivani P; Morgan, Rebecca L; Sartorius, Benn; Dennis, Brittany; Drain, Paul K; Thabane, Lehana
2017-01-01
Introduction The World Health Organization advocates for increased accessibility of HIV-related point-of-care (POC) diagnostics in settings that lack laboratory infrastructure. The aim of this study is to assess the impact of POC diagnostics on maternal health outcomes in HIV-infected women. Methods A systematic literature review used multiple data sources as follows: Cochrane Infectious Disease Group Specialized Register; Cochrane Central Register of Control Trials, published in The Cochrane Library; PubMed; EBSCOhost and LILACS from January 2000 to October 2015. References of included studies were hand searched. Randomized controlled trials (RCTs) and observational studies examining health outcomes of HIV-infected women were eligible for inclusion in this review. The Cochrane Risk of Bias tool was used for bias assessment of the included studies. PRISMA guidelines were used for reporting. Results Of the 695 studies identified, six retrievable studies (five cross-sectional studies and one case control study) met the inclusion criteria and were included in this study. These studies examined a total of 167 HIV-infected women in different study settings. No studies reported evidence of CD4 count, viral load and TB, and the syphilis POC test impact on HIV-infected women was not found by this study. Included studies reported the impact of various HIV rapid tests across the following five maternal outcomes: timely receipt of results with pooled effect size (ES) = 1.00 (95% confidence interval [CI]: (0.98; 1.02); enabling partner testing, ES = 0.95 (0.85; 1.04); prevention of mother-to-child transmission of HIV, ES = 0.86 (0.79; 0.93); linkage to antiretroviral treatment (ART), ES = 0.76 (0.69; 0.84); and linkage to HIV care, ES = 0.50 (0.18; 0.82). No studies reported evidence of the impact of POC testing on maternal mortality or maternal and child morbidity of HIV-infected women. Conclusions The review provides an international overview of the impact of HIV POC
Hohenstein, Jess; O'Dell, Dakota; Murnane, Elizabeth L; Lu, Zhengda; Erickson, David; Gay, Geri
2017-11-21
In today's health care environment, increasing costs and inadequate medical resources have created a worldwide need for more affordable diagnostic tools that are also portable, fast, and easy to use. To address this issue, numerous research and commercial efforts have focused on developing rapid diagnostic technologies; however, the efficacy of existing systems has been hindered by usability problems or high production costs, making them infeasible for deployment in at-home, point-of-care (POC), or resource-limited settings. The aim of this study was to create a low-cost optical reader system that integrates with any smart device and accepts any type of rapid diagnostic test strip to provide fast and accurate data collection, sample analysis, and diagnostic result reporting. An iterative design methodology was employed by a multidisciplinary research team to engineer three versions of a portable diagnostic testing device that were evaluated for usability and overall user receptivity. Repeated design critiques and usability studies identified a number of system requirements and considerations (eg, software compatibility, biomatter contamination, and physical footprint) that we worked to incrementally incorporate into successive system variants. Our final design phase culminated in the development of Tidbit, a reader that is compatible with any Wi-Fi-enabled device and test strip format. The Tidbit includes various features that support intuitive operation, including a straightforward test strip insertion point, external indicator lights, concealed electronic components, and an asymmetric shape, which inherently signals correct device orientation. Usability testing of the Tidbit indicates high usability for potential user communities. This study presents the design process, specification, and user reception of the Tidbit, an inexpensive, easy-to-use, portable optical reader for fast, accurate quantification of rapid diagnostic test results. Usability testing suggests
Hatchette, Todd F; Bastien, Nathalie; Berry, Jody; Booth, Tim F; Chernesky, Max; Couillard, Michel; Drews, Steven; Ebsworth, Anthony; Fearon, Margaret; Fonseca, Kevin; Fox, Julie; Gagnon, Jean-Nicolas; Guercio, Steven; Horsman, Greg; Jorowski, Cathy; Kuschak, Theodore; Li, Yan; Majury, Anna; Petric, Martin; Ratnam, Sam; Smieja, Marek; Van Caeseele, Paul
2009-01-01
As the world prepares for the next influenza pandemic, governments have made significant funding commitments to vaccine development and antiviral stockpiling. While these are essential components to pandemic response, rapid and accurate diagnostic testing remains an often neglected cornerstone of pandemic influenza preparedness. Clinicians and Public Health Practitioners need to understand the benefits and drawbacks of different influenza tests in both seasonal and pandemic settings. Culture has been the traditional gold standard for influenza diagnosis but requires from 1-10 days to generate a positive result, compared to nucleic acid detection methods such as real time reverse transcriptase polymerase chain reaction (RT-PCR). Although the currently available rapid antigen detection kits can generate results in less than 30 minutes, their sensitivity is suboptimal and they are not recommended for the detection of novel influenza viruses. Until point-of-care (POC) tests are improved, PILPN recommends that the best option for pandemic influenza preparation is the enhancement of nucleic acid-based testing capabilities across Canada.
Suzuki, Kenichiro; Komukai, Kimiaki; Nakata, Kotaro; Kan, Renshi; Oi, Yuhei; Muto, Eri; Kashiwagi, Yusuke; Tominaga, Mitsutoshi; Miyanaga, Satoru; Ishikawa, Tetsuya; Okuno, Kenji; Uzura, Masahiko; Yoshimura, Michihiro
2018-02-09
Objective This study was carried out to examine the usefulness of point-of-care (POC) cardiac troponin in diagnosing acute coronary syndrome (ACS) and to understand the limitations of a POC cardiac troponin I/T-based diagnoses. Methods Patients whose cardiac troponin levels were measured in the emergency department using a POC system (AQT System; Radiometer, Tokyo, Japan) between January and December 2016 were retrospectively examined (N=1449). Patients who were < 20 years of age or who were admitted with cardiopulmonary arrest were excluded. The sensitivity and specificity of the POC cardiac troponin levels for the diagnosis of ACS were determined. Result One hundred and twenty of 1449 total patients had ACS (acute myocardial infarction, n=88; unstable angina n=32). On comparing the receiver operating characteristic (ROC) curves, the area under the curve (AUC) values for POC cardiac troponin I and cardiac troponin T were 0.833 and 0.786, respectively. The sensitivity and specificity of POC cardiac troponin I when using the 99th percentile (0.023 ng/mL) as the diagnostic cut-off value were 69.0% and 88.1%, respectively. The sensitivity of POC cardiac troponin I (99th percentile) was higher in the patients sampled > 3 h after symptom onset (83.3%) than in those sampled ≤ 3 h after symptom onset (58.8%, p < 0.01). Conclusion When sampled > 3 h after the onset of symptoms, the POC cardiac troponin I level is considered to be suitable for use in diagnosing ACS. However, when sampled ≤ 3 h after the onset of symptoms, careful interpretation of POC cardiac troponins is therefore required to rule out ACS.
Oppong, Raymond; Jit, Mark; Smith, Richard D; Butler, Christopher C; Melbye, Hasse; Mölstad, Sigvard; Coast, Joanna
2013-01-01
Background Point-of-care C-reactive protein (POCCRP) is a biomarker of inflammation that offers clinicians a rapid POC test to guide antibiotic prescribing decisions for acute cough and lower respiratory tract infections (LRTI). However, evidence that POCCRP is cost-effective is limited, particularly outside experimental settings. Aim To assess the cost-effectiveness of POCCRP as a diagnostic tool for acute cough and LRTI from the perspective of the health service. Design and setting Observational study of the presentation, management, and outcomes of patients with acute cough and LRTI in primary care settings in Norway and Sweden. Method Using hierarchical regression, data were analysed in terms of the effect on antibiotic use, cost, and patient outcomes (symptom severity after 7 and 14 days, time to recovery, and EQ-5D), while controlling for patient characteristics (self-reported symptom severity, comorbidities, and health-related quality of life) at first attendance. Results POCCRP testing is associated with non-significant positive reductions in antibiotic prescribing (P = 0.078) and increased cost (P = 0.092). Despite the uncertainty, POCCRP testing is also associated with a cost per quality-adjusted life year (QALY) gain of €9391. At a willingness-to-pay threshold of €30 000 per QALY gained, there is a 70% probability of CRP being cost-effective. Conclusion POCCRP testing is likely to provide a cost-effective diagnostic intervention both in terms of reducing antibiotic prescribing and in terms of QALYs gained. PMID:23834883
Requirements for Successful Adoption of a Glucose Measurement System Into a Hospital POC Program.
Füzéry, Anna K; Cembrowski, George S
2016-07-01
Widespread and successful implementation of any glucose measurement system in a hospital point-of-care (POC) program requires a number of features in addition to accurate and reliable analytical performance. Such features include, but are not limited to, a system's glucose-hematocrit dependence, durability, information technology capabilities, and battery capacity and battery life. While the study of Ottiger et al in this issue supports the analytical accuracy and reliability of Bayer's CONTOUR XT® blood glucose monitoring system, the suitability of other features of this system for a hospital POC program remains to be established. © 2016 Diabetes Technology Society.
Miniaturized Bio-and Chemical-Sensors for Point-of-Care Monitoring of Chronic Kidney Diseases.
Tricoli, Antonio; Neri, Giovanni
2018-03-22
This review reports the latest achievements in point-of-care (POC) sensor technologies for the monitoring of ammonia, creatinine and urea in patients suffering of chronic kidney diseases (CKDs). Abnormal levels of these nitrogen biomarkers are found in the physiological fluids, such as blood, urine and sweat, of CKD patients. Delocalized at-home monitoring of CKD biomarkers via integration of miniaturized, portable, and low cost chemical- and bio-sensors in POC devices, is an emerging approach to improve patients' health monitoring and life quality. The successful monitoring of CKD biomarkers, performed on the different body fluids by means of sensors having strict requirements in term of size, cost, large-scale production capacity, response time and simple operation procedures for use in POC devices, is reported and discussed.
Mangwiro, Alexio-Zambezi; Makomva, Kudzai; Bhattacharya, Antoinette; Bhattacharya, Gaurav; Gotora, Tendai; Owen, Mila; Mushavi, Angela; Mangwanya, Douglas; Zinyowera, Sekesai; Rusakaniko, Simbarashe; Mugurungi, Owen; Zizhou, Simukai; Busumani, William; Masuka, Nyasha
2014-11-01
Evidence for Elimination (E4E) is a collaborative project established in 2012 as part of the INSPIRE (INtegrating and Scaling up PMTCT through Implementation REsearch) initiative. E4E is a cluster-randomized trial with 2 arms; Standard of care and "POC Plus" [in which point-of-care (POC) CD4 devices and related counseling support are provided]; aimed at improving retention-in-care of HIV-infected pregnant women and mothers. In November 2013, Zimbabwe adopted Option B+ for HIV-positive pregnant women under which antiretroviral treatment eligibility is no longer based on CD4 count. However, Ministry of Health and Child Care guidelines still require baseline and 6-monthly CD4 testing for treatment monitoring, until viral load testing becomes widely available. Considering the current limited capacity for viral-load testing, the significant investments in CD4 testing already made and the historical reliance on CD4 by health care workers for determining eligibility for antiretroviral treatment, E4E seeks to compare the impact of the provision of POC CD4 technology and early knowledge of CD4 levels on retention-in-care at 12 months, with the current standard of routine, laboratory-based CD4 testing. The study also compares rates of initiation and time-to-initiation between the 2 arms and according to level of maternal CD4 count, the cost of retaining HIV-positive pregnant women in care and the acceptability and feasibility of POC CD4 in the context of Option B+. Outcome measures are derived from routine health systems data. E4E will provide data on POC CD4 testing and retention-in-care associated with Option B+ and serve as an early learning platform to inform implementation of Option B+ in Zimbabwe.
Optimizing point-of-care testing in clinical systems management.
Kost, G J
1998-01-01
The goal of improving medical and economic outcomes calls for leadership based on fundamental principles. The manager of clinical systems works collaboratively within the acute care center to optimize point-of-care testing through systematic approaches such as integrative strategies, algorithms, and performance maps. These approaches are effective and efficacious for critically ill patients. Optimizing point-of-care testing throughout the entire health-care system is inherently more difficult. There is potential to achieve high-quality testing, integrated disease management, and equitable health-care delivery. Despite rapid change and economic uncertainty, a macro-strategic, information-integrated, feedback-systems, outcomes-oriented approach is timely, challenging, effective, and uplifting to the creative human spirit.
Louie, Richard F; Ferguson, William J; Curtis, Corbin M; Vy, John H; Tang, Chloe S; Kost, Gerald J
2013-01-01
To characterize the effects of environmental stress on point-of-care (POC) cardiac biomarker testing during a simulated rescue. Multiplex test cassettes for cardiac troponin I (cTnI), brain natriuretic peptide (BNP), CK-MB, myoglobin, and D-dimer were exposed to environmental stresses simulating a 24-hour rescue from Hawaii to the Marshall Islands and back. We used Tenney environmental chambers (T2RC and BTRC) to simulate flight conditions (20°C, 10 percent relative humidity) and ground conditions (22.3-33.9°C, 73-77 percent). We obtained paired measurements using stressed versus control (room temperature) cassettes at seven time points (T1-7 with T1,2,6,7 during flight and T3-5 on ground). We analyzed paired differences (stressed minus control) with Wilcoxon signed rank test. We assessed the impact on decision-making at clinical thresholds. cTnI results from stressed test cassettes (n = 10) at T4 (p < 0.05), T5 (p < 0.01), and T7 (p < 0.05) differed significantly from control, when testing samples with median cTnI concentration of 90 ng/L. During the ground rescue, 36.7 percent (11/30) of cTnI measurements from stressed cassettes generated significantly lowered results. At T5, 20 percent (2/10) of cTnI results were highly discrepant-stressed cassettes reported normal results, when control results were >100 ng/L. With sample median concentration of 108 pg/mL, BNP results from stressed test cassettes differed significantly from controls (p < 0.05). Despite modest, short-term temperature elevation, environmental stresses led to erroneous results. False negative cTnI and BNP results potentially could miss acute myocardial infarction and congestive heart failure, confounded treatment, and increased mortality and morbidity. Therefore, rescuers should protect POC reagents from temperature extremes.
Cassim, Naseem; Coetzee, Lindi M; Schnippel, Kathryn; Glencross, Deborah K
2014-01-01
An integrated tiered service delivery model (ITSDM) has been proposed to provide 'full-coverage' of CD4 services throughout South Africa. Five tiers are described, defined by testing volumes and number of referring health-facilities. These include: (1) Tier-1/decentralized point-of-care service (POC) in a single site; Tier-2/POC-hub servicing processing < 30-40 samples from 8-10 health-clinics; Tier-3/Community laboratories servicing ∼ 50 health-clinics, processing < 150 samples/day; high-volume centralized laboratories (Tier-4 and Tier-5) processing < 300 or > 600 samples/day and serving > 100 or > 200 health-clinics, respectively. The objective of this study was to establish costs of existing and ITSDM-tiers 1, 2 and 3 in a remote, under-serviced district in South Africa. Historical health-facility workload volumes from the Pixley-ka-Seme district, and the total volumes of CD4 tests performed by the adjacent district referral CD4 laboratories, linked to locations of all referring clinics and related laboratory-to-result turn-around time (LTR-TAT) data, were extracted from the NHLS Corporate-Data-Warehouse for the period April-2012 to March-2013. Tiers were costed separately (as a cost-per-result) including equipment, staffing, reagents and test consumable costs. A one-way sensitivity analyses provided for changes in reagent price, test volumes and personnel time. The lowest cost-per-result was noted for the existing laboratory-based Tiers- 4 and 5 ($6.24 and $5.37 respectively), but with related increased LTR-TAT of > 24-48 hours. Full service coverage with TAT < 6-hours could be achieved with placement of twenty-seven Tier-1/POC or eight Tier-2/POC-hubs, at a cost-per-result of $32.32 and $15.88 respectively. A single district Tier-3 laboratory also ensured 'full service coverage' and < 24 hour LTR-TAT for the district at $7.42 per-test. Implementing a single Tier-3/community laboratory to extend and improve delivery of services in Pixley-ka-Seme, with an
Shephard, Mark; Shephard, Anne; McAteer, Bridgit; Regnier, Tamika; Barancek, Kristina
2017-12-01
Diabetes is a major health problem for Australia's Aboriginal and Torres Strait Islander peoples. Point-of-care testing for haemoglobin A1c (HbA1c) has been the cornerstone of a long-standing program (QAAMS) to manage glycaemic control in Indigenous people with diabetes and recently, to diagnose diabetes. The QAAMS quality management framework includes monthly testing of quality control (QC) and external quality assurance (EQA) samples. Key performance indicators of quality include imprecision (coefficient of variation [CV%]) and percentage acceptable results. This paper reports on the past 15years of quality testing in QAAMS and examines the performance of HbA1c POC testing at the 6.5% cut-off recommended for diagnosis. The total number of HbA1c EQA results submitted from 2002 to 2016 was 29,093. The median imprecision for EQA testing by QAAMS device operators averaged 2.81% (SD 0.50; range 2.2 to 3.9%) from 2002 to 2016 and 2.44% (SD 0.22; range 2.2 to 2.9%) from 2009 to 2016. No significant difference was observed between the median imprecision achieved in QAAMS and by Australasian laboratories from 2002 to 2016 (p=0.05; two-tailed paired t-test) and from 2009 to 2016 (p=0.17; two-tailed paired t-test). For QC testing from 2009 to 2016, imprecision averaged 2.5% and 3.0% for the two levels of QC tested. Percentage acceptable results averaged 90% for QA testing from 2002 to 2016 and 96% for QC testing from 2009 to 2016. The DCA Vantage was able to measure a patient and an EQA sample with an HbA1c value close to 6.5% both accurately and precisely. HbA1c POC testing in QAAMS has remained analytically sound, matched the quality achieved by Australasian laboratories and met profession-derived analytical goals for 15years. Copyright © 2017 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.
Miniaturized Bio-and Chemical-Sensors for Point-of-Care Monitoring of Chronic Kidney Diseases
Tricoli, Antonio
2018-01-01
This review reports the latest achievements in point-of-care (POC) sensor technologies for the monitoring of ammonia, creatinine and urea in patients suffering of chronic kidney diseases (CKDs). Abnormal levels of these nitrogen biomarkers are found in the physiological fluids, such as blood, urine and sweat, of CKD patients. Delocalized at-home monitoring of CKD biomarkers via integration of miniaturized, portable, and low cost chemical- and bio-sensors in POC devices, is an emerging approach to improve patients’ health monitoring and life quality. The successful monitoring of CKD biomarkers, performed on the different body fluids by means of sensors having strict requirements in term of size, cost, large-scale production capacity, response time and simple operation procedures for use in POC devices, is reported and discussed. PMID:29565315
Beissner, Marcus; Phillips, Richard Odame; Battke, Florian; Bauer, Malkin; Badziklou, Kossi; Sarfo, Fred Stephen; Maman, Issaka; Rhomberg, Agata; Piten, Ebekalisai; Frimpong, Michael; Huber, Kristina Lydia; Symank, Dominik; Jansson, Moritz; Wiedemann, Franz Xaver; Banla Kere, Abiba; Herbinger, Karl-Heinz; Löscher, Thomas; Bretzel, Gisela
2015-01-01
Background As the major burden of Buruli ulcer disease (BUD) occurs in remote rural areas, development of point-of-care (POC) tests is considered a research priority to bring diagnostic services closer to the patients. Loop-mediated isothermal amplification (LAMP), a simple, robust and cost-effective technology, has been selected as a promising POC test candidate. Three BUD-specific LAMP assays are available to date, but various technical challenges still hamper decentralized application. To overcome the requirement of cold-chains for transport and storage of reagents, the aim of this study was to establish a dry-reagent-based LAMP assay (DRB-LAMP) employing lyophilized reagents. Methodology/Principal Findings Following the design of an IS2404 based conventional LAMP (cLAMP) assay suitable to apply lyophilized reagents, a lyophylization protocol for the DRB-LAMP format was developed. Clinical performance of cLAMP was validated through testing of 140 clinical samples from 91 suspected BUD cases by routine assays, i.e. IS2404 dry-reagent-based (DRB) PCR, conventional IS2404 PCR (cPCR), IS2404 qPCR, compared to cLAMP. Whereas qPCR rendered an additional 10% of confirmed cases and samples respectively, case confirmation and positivity rates of DRB-PCR or cPCR (64.84% and 56.43%; 100% concordant results in both assays) and cLAMP (62.64% and 52.86%) were comparable and there was no significant difference between the sensitivity of the assays (DRB PCR and cPCR, 86.76%; cLAMP, 83.82%). Likewise, sensitivity of cLAMP (95.83%) and DRB-LAMP (91.67%) were comparable as determined on a set of 24 samples tested positive in all routine assays. Conclusions/Significance Both LAMP formats constitute equivalent alternatives to conventional PCR techniques. Provided the envisaged availability of field friendly DNA extraction formats, both assays are suitable for decentralized laboratory confirmation of BUD, whereby DRB-LAMP scores with the additional advantage of not requiring cold
Iijima, Shigeo; Baba, Toru; Ueno, Daizo; Ohishi, Akira
2016-09-01
Early infants are at risk of vitamin K (VK) deficiency-associated bleeding unless they receive VK prophylaxis. A coagulation screening test might be necessary to detect prophylactic failure, but it is rarely conducted owing to the difficulty of blood sampling. CoaguChek XS is a portable, point-of-care (POC) coagulation analyzer that determines international normalized ratios (INRs) using only small volumes of blood. Although POC tests assessing INR have become widespread for adults, studies have not been performed in early infancy. This study aimed to determine the reference interval (RI) for INR for 1-month-old infants using the CoaguChek XS and to compare INRs with Normotest (NT) values to evaluate its efficacy as a VK deficiency screening test. This study included 578 consecutive 1-month-old, healthy, term infants who underwent a 1-month health checkup. CoaguChek XS INRs and NT values were analyzed for each subject. The enrolled neonates were orally administered VK 6-12h and 4days after birth. An INR RI for 1-month-old infants was established using the CoaguChek XS (range of 0.9-1.1). On the other hand, the NT RI was 69%-130%. We observed a significant inverse correlation between INRs and NT values. Our study is the first to establish an INR RI using the CoaguChek XS for 1-month-old, healthy, term infants. CoaguChek XS INR was more convenient to test than NT. However, we could not demonstrate its efficacy as a VK deficiency screening test because no infant had an aberrant NT value or a bleeding disorder. Copyright © 2016 Elsevier Ltd. All rights reserved.
Ultra low-cost, portable smartphone optosensors for mobile point-of-care diagnostics
NASA Astrophysics Data System (ADS)
Wang, Li-Ju; Chang, Yu-Chung; Sun, Rongrong; Li, Lei
2018-02-01
Smartphone optosensors with integrated optical components make mobile point-of-care (MPoC) diagnostics be done near patients' side. It'll especially have a significant impact on healthcare delivery in rural or remote areas. Current FDA-approved PoC devices achieving clinical level are still at high cost and not affordable in rural hospitals. We present a series of ultra low-cost smartphone optical sensing devices for mobile point-of-care diagnosis. Aiming different targeting analytes and sensing mechanisms, we developed custom required optical components for each smartphone optosensros. These optical devices include spectrum readers, colorimetric readers for microplate, lateral flow device readers, and chemiluminescence readers. By integrating our unique designed optical components into smartphone optosening platform, the anlaytes can be precisely detected. Clinical testing results show the clinical usability of our smartphone optosensors. Ultra low-cost portable smartphone optosensors are affordable for rural/remote doctors.
Wireless Integrated Biosensors for Point-of-Care Diagnostic Applications
Ghafar-Zadeh, Ebrahim
2015-01-01
Recent advances in integrated biosensors, wireless communication and power harvesting techniques are enticing researchers into spawning a new breed of point-of-care (POC) diagnostic devices that have attracted significant interest from industry. Among these, it is the ones equipped with wireless capabilities that drew our attention in this review paper. Indeed, wireless POC devices offer a great advantage, that of the possibility of exerting continuous monitoring of biologically relevant parameters, metabolites and other bio-molecules, relevant to the management of various morbid diseases such as diabetes, brain cancer, ischemia, and Alzheimer’s. In this review paper, we examine three major categories of miniaturized integrated devices, namely; the implantable Wireless Bio-Sensors (WBSs), the wearable WBSs and the handheld WBSs. In practice, despite the aforesaid progress made in developing wireless platforms, early detection of health imbalances remains a grand challenge from both the technological and the medical points of view. This paper addresses such challenges and reports the state-of-the-art in this interdisciplinary field. PMID:25648709
Microfluidic-integrated biosensors: prospects for point-of-care diagnostics.
Kumar, Suveen; Kumar, Saurabh; Ali, Md Azahar; Anand, Pinki; Agrawal, Ved Varun; John, Renu; Maji, Sagar; Malhotra, Bansi D
2013-11-01
There is a growing demand to integrate biosensors with microfluidics to provide miniaturized platforms with many favorable properties, such as reduced sample volume, decreased processing time, low cost analysis and low reagent consumption. These microfluidics-integrated biosensors would also have numerous advantages such as laminar flow, minimal handling of hazardous materials, multiple sample detection in parallel, portability and versatility in design. Microfluidics involves the science and technology of manipulation of fluids at the micro- to nano-liter level. It is predicted that combining biosensors with microfluidic chips will yield enhanced analytical capability, and widen the possibilities for applications in clinical diagnostics. The recent developments in microfluidics have helped researchers working in industries and educational institutes to adopt some of these platforms for point-of-care (POC) diagnostics. This review focuses on the latest advancements in the fields of microfluidic biosensing technologies, and on the challenges and possible solutions for translation of this technology for POC diagnostic applications. We also discuss the fabrication techniques required for developing microfluidic-integrated biosensors, recently reported biomarkers, and the prospects of POC diagnostics in the medical industry. Copyright © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Larson, Bruce; Schnippel, Kathryn; Ndibongo, Buyiswa; Long, Lawrence; Fox, Matthew P; Rosen, Sydney
2012-01-01
Integrating POC CD4 testing technologies into HIV counseling and testing (HCT) programs may improve post-HIV testing linkage to care and treatment. As evaluations of these technologies in program settings continue, estimates of the costs of POC CD4 tests to the service provider will be needed and estimates have begun to be reported. Without a consistent and transparent methodology, estimates of the cost per CD4 test using POC technologies are likely to be difficult to compare and may lead to erroneous conclusions about costs and cost-effectiveness. This paper provides a step-by-step approach for estimating the cost per CD4 test from a provider's perspective. As an example, the approach is applied to one specific POC technology, the Pima Analyzer. The costing approach is illustrated with data from a mobile HCT program in Gauteng Province of South Africa. For this program, the cost per test in 2010 was estimated at $23.76 (material costs = $8.70; labor cost per test = $7.33; and equipment, insurance, and daily quality control = $7.72). Labor and equipment costs can vary widely depending on how the program operates and the number of CD4 tests completed over time. Additional costs not included in the above analysis, for on-going training, supervision, and quality control, are likely to increase further the cost per test. The main contribution of this paper is to outline a methodology for estimating the costs of incorporating POC CD4 testing technologies into an HCT program. The details of the program setting matter significantly for the cost estimate, so that such details should be clearly documented to improve the consistency, transparency, and comparability of cost estimates.
Veerasami, Maroudam; Venkataraman, K; Karuppannan, Chitra; Shanmugam, Arun Attur; Prudhvi, Mallepaddi Chand; Holder, Thomas; Rathnagiri, Polavarapu; Arunmozhivarman, K; Raj, Gopal Dhinakar; Vordermeier, Martin; Mohana Subramanian, B
2018-03-01
Tuberculosis is a significant problem globally for domestic animals as well as captive and free ranging wild life. Rapid point of care (POC) serology kits are well suited for the diagnosis of TB in wild animals. However, wild animals are invariably exposed to environmental non-pathogenic mycobacterium species with the development of cross reacting antibodies. In the present study, POC TB diagnosis kit was developed using a combination of pathogenic Mycobacteria specific recombinant antigens and purified protein derivatives of pathogenic and non-pathogenic Mycobacteria . To benchmark the TB antibody detection kit, particularly in respect to specificity which could not be determined in wildlife due to the lack of samples from confirmed uninfected animals, we first tested well-characterized sera from 100 M. bovis infected and 100 uninfected cattle. Then we investigated the kit's performance using sera samples from wildlife, namely Sloth Bears (n = 74), Elephants (n = 9), Cervidae (n = 14), Felidae (n = 21), Cape buffalo (n = 2), Wild bear (n = 1) and Wild dog (n = 1).In cattle, a sensitivity of 81% and a specificity of 90% were obtained. The diagnostic sensitivity of the kit was 94% when the kit was tested using known TB positive sloth bear sera samples. 47.4% of the in-contact sloth bears turned seropositive using the rapid POC TB diagnostic kit. Seropositivity in other wild animals was 25% when the sera samples were tested using the kit. A point of care TB sero-diagnostic kit with the combination of proteins was developed and the kit was validated using the sera samples of wild animals.
Martin, J; Schuster, T; Moessmer, G; Kochs, E F; Wagner, K J
2012-10-01
Thromboelastometry as point-of-care (POC) testing enables the analysis of the clotting process at the bedside, providing rapid results to guide haemostatic therapy. However, POC testing utilizes medical staff who are managing critically ill patients, as non-laboratory personnel may not be sufficiently trained to run the devices. To resolve these problems, thromboelastometry can be performed in the central laboratory and rapid transport of samples can be accomplished via a pneumatic tube system (PTS). This study compares thromboelastometry parameters of blood samples analysed immediately with those analysed after PTS transport. In patients with normal haemostasis, two arterial blood samples were collected from each patient (n=92) in citrated plastic tubes to investigate the assays INTEM (n=35), EXTEM (n=27), and FIBTEM (n=30). One blood sample was analysed immediately, the other sample after PTS transport. Thromboelastometry was performed using a single ROTEM(®) device. The mean clot firmness values were significantly lower for PTS samples in both the INTEM (-0.7 mm cf. -1.1 mm) and EXTEM (-1.4 cf. -1.7 mm) assays. INTEM coagulation time (CT) was significantly lower in PTS samples with a mean difference of -13 s. EXTEM CT was significantly higher in PTS samples with a mean difference of +3.9 s. Thromboelastometry parameters of blood samples analysed after PTS transport are significantly altered compared with those analysed immediately. However, in patients with normal haemostasis, the alterations were small and without clinical consequence, implying that analysis after PTS transport is an acceptable alternative to prompt analysis at the bedside. Further studies should focus on patients with impaired haemostasis.
Shephard, Mark DS; Gill, Janice P
2006-01-01
Type 2 diabetes mellitus and its major complication, renal disease, represent one of the most significant contemporary health problems facing Australia’s Indigenous Aboriginal People. The Australian Government-funded Quality Assurance for Aboriginal Medical Services Program (QAAMS) provides a framework by which on-site point-of-care testing (POCT) for haemoglobin A1c (HbA1c) and now urine albumin:creatinine ratio (ACR) can be performed to facilitate better diabetes management in Aboriginal medical services. This paper provides updated evidence for the analytical quality of POCT in the QAAMS Program. The median imprecision for point-of-care (POC) HbA1c and urine ACR quality assurance (QA) testing has continually improved over the past six and half years, stabilising at approximately 3% for both analytes and proving analytically sound in Aboriginal hands. For HbA1c, there was no statistical difference between the imprecision achieved by QAAMS and laboratory users of the Bayer DCA 2000 since the QAAMS program commenced (QAAMS CV 3.6% ± 0.52, laboratory CV 3.4% ± 0.42; p = 0.21, paired t-test). The Western Pacific Island of Tonga recently joined the QAAMS HbA1c Program indicating that the QAAMS model can also be applied internationally in other settings where the prevalence of diabetes is high. PMID:17581642
Blank, Fidela S J; Miller, Moses; Nichols, James; Smithline, Howard; Crabb, Gillian; Pekow, Penelope
2009-04-01
The purpose of this study is to compare blood glucose levels measured by a point of care (POC) device to laboratory measurement using the same sample venous blood from patients with suspected diabetic ketoacidosis (DKA). A descriptive correlational design was used for this IRB-approved quality assurance project. The study site was the 50-bed BMC emergency department (ED) which has an annual census of over 100,000 patient visits. The convenience sample consisted of 54 blood samples from suspected DKA patients with orders for hourly blood draws for glucose measurement. Spearman correlations of the glucose POC values, reference lab values, and differences between the two, were evaluated. A chi-square test was used to evaluate the association between the acidosis status and FDA acceptability of POC values. Patient age range was 10-86 years; 63% were females; 46% had a final diagnosis of DKA. POC values underestimated glucose levels 93% of the time. There was a high correlation between the lab value and the magnitude of the difference, (lab minus POC value) indicating that the higher the true glucose value, the greater the difference between the lab and the POC value. A chi-square test showed no overall association between acidosis and FDA-acceptability. The POC values underestimated lab reported glucose levels in 50 of 54 cases even with the use of same venous sample sent to the lab, which make it highly unreliable for use in monitoring suspected DKA patients.
Barbosa, Ana I; Reis, Nuno M
2017-03-13
The latest clinical procedures for the timely and cost-effective diagnosis of chronic and acute clinical conditions, such as cardiovascular diseases, cancer, chronic respiratory diseases, diabetes or sepsis (i.e. the biggest causes of death worldwide), involve the quantitation of specific protein biomarkers released into the blood stream or other physiological fluids (e.g. urine or saliva). The clinical thresholds are usually in the femtomolar to picolomar range, and consequently the measurement of these protein biomarkers heavily relies on highly sophisticated, bulky and automated equipment in centralised pathology laboratories. The first microfluidic devices capable of measuring protein biomarkers in miniaturised immunoassays were presented nearly two decades ago and promised to revolutionise point-of-care (POC) testing by offering unmatched sensitivity and automation in a compact POC format; however, the development and adoption of microfluidic protein biomarker tests has fallen behind expectations. This review presents a detailed critical overview into the pipeline of microfluidic devices developed in the period 2005-2016 capable of measuring protein biomarkers from the pM to fM range in formats compatible with POC testing, with a particular focus on the use of affordable microfluidic materials and compact low-cost signal interrogation. The integration of these two important features (essential unique selling points for the successful microfluidic diagnostic products) has been missed in previous review articles and explain the poor adoption of microfluidic technologies in this field. Most current miniaturised devices compromise either on the affordability, compactness and/or performance of the test, making current tests unsuitable for the POC measurement of protein biomarkers. Seven core technical areas, including (i) the selected strategy for antibody immobilisation, (ii) the surface area and surface-area-to-volume ratio, (iii) surface passivation, (iv) the
Raila, Jens; Enjalbert, Francis; Mothes, Ralf; Hurtienne, Andrea; Schweigert, Florian J
2012-03-01
β-Carotene is an important precursor of vitamin A, and is associated with bovine fertility. β-Carotene concentrations in plasma are used to optimize β-carotene supplementation in cattle, but measurement requires specialized equipment to separate plasma and extract and measure β-carotene, either using spectrophotometry or high performance liquid chromatography (HPLC). The objective of this study was to validate a new 2-step point-of-care (POC) assay for measuring β-carotene in whole blood and plasma. β-carotene concentrations in plasma from 166 cows were measured using HPLC and compared with results obtained using a POC assay, the iCheck-iEx-Carotene test kit. Whole blood samples from 23 of these cattle were also evaluated using the POC assay and compared with HPLC-plasma results from the same 23 animals. The POC assay includes an extraction vial (iEx Carotene) and hand-held photometer (iCheck Carotene). Concentrations of β-carotene in plasma measured using the POC assay ranged from 0.40 to 15.84 mg/L (n = 166). No differences were observed between methods for assay of plasma (mean ± SD; n = 166): HPLC-plasma 4.23 ± 2.35 mg/L; POC-plasma 4.49 ± 2.36 mg/L. Similar good agreement was found when plasma analyzed using HPLC was compared with whole blood analyzed using the POC system (n = 23): HPLC-plasma 3.46 ± 2.12 mg/L; POC-whole blood 3.67 ± 2.29 mg/L. Concentrations of β-carotene can be measured in blood and plasma from cattle easily and rapidly using a POC assay, and results are comparable to those obtained by the highly sophisticated HPLC method. Immediate feedback regarding β-carotene deficiency facilitates rapid and appropriate optimization of β-carotene supplementation in feed. © 2012 American Society for Veterinary Clinical Pathology.
Photonic crystals: emerging biosensors and their promise for point-of-care applications.
Inan, Hakan; Poyraz, Muhammet; Inci, Fatih; Lifson, Mark A; Baday, Murat; Cunningham, Brian T; Demirci, Utkan
2017-01-23
Biosensors are extensively employed for diagnosing a broad array of diseases and disorders in clinical settings worldwide. The implementation of biosensors at the point-of-care (POC), such as at primary clinics or the bedside, faces impediments because they may require highly trained personnel, have long assay times, large sizes, and high instrumental cost. Thus, there exists a need to develop inexpensive, reliable, user-friendly, and compact biosensing systems at the POC. Biosensors incorporated with photonic crystal (PC) structures hold promise to address many of the aforementioned challenges facing the development of new POC diagnostics. Currently, PC-based biosensors have been employed for detecting a variety of biotargets, such as cells, pathogens, proteins, antibodies, and nucleic acids, with high efficiency and selectivity. In this review, we provide a broad overview of PCs by explaining their structures, fabrication techniques, and sensing principles. Furthermore, we discuss recent applications of PC-based biosensors incorporated with emerging technologies, including telemedicine, flexible and wearable sensing, smart materials and metamaterials. Finally, we discuss current challenges associated with existing biosensors, and provide an outlook for PC-based biosensors and their promise at the POC.
Point-of-Care Diagnostics in Low Resource Settings: Present Status and Future Role of Microfluidics
Sharma, Shikha; Zapatero-Rodríguez, Julia; Estrela, Pedro; O’Kennedy, Richard
2015-01-01
The inability to diagnose numerous diseases rapidly is a significant cause of the disparity of deaths resulting from both communicable and non-communicable diseases in the developing world in comparison to the developed world. Existing diagnostic instrumentation usually requires sophisticated infrastructure, stable electrical power, expensive reagents, long assay times, and highly trained personnel which is not often available in limited resource settings. This review will critically survey and analyse the current lateral flow-based point-of-care (POC) technologies, which have made a major impact on diagnostic testing in developing countries over the last 50 years. The future of POC technologies including the applications of microfluidics, which allows miniaturisation and integration of complex functions that facilitate their usage in limited resource settings, is discussed The advantages offered by such systems, including low cost, ruggedness and the capacity to generate accurate and reliable results rapidly, are well suited to the clinical and social settings of the developing world. PMID:26287254
Clinical performance of a new point-of-care cardiac troponin I test.
Christ, Michael; Geier, Felicitas; Blaschke, Sabine; Giannitsis, Evangelos; Khellaf, Mehdi; Mair, Johannes; Pariente, David; Scharnhorst, Volkher; Semjonow, Veronique; Hausfater, Pierre
2018-04-09
We evaluated the clinical performance of the Minicare cardiac troponin-I (cTnI), a new point-of-care (POC) cTnI test for the diagnosis of acute myocardial infarction (AMI) in a prospective, multicentre study (ISRCTN77371338). Of 474 patients (≥18 years) admitted to an emergency department (ED) or chest pain unit (CPU) with symptoms suggestive of acute coronary syndrome (ACS; ≤12 h from symptom onset), 465 were eligible. Minicare cTnI was tested immediately, 3 h and 6 h after presentation. AMI diagnoses were adjudicated independently based on current guidelines. The diagnostic performance of the Minicare cTnI test at 3 h was similar for whole blood and in plasma: sensitivity 0.92 vs. 0.90; specificity 0.91 vs. 0.90; positive predictive value (PPV) 0.68 vs. 0.66; negative predictive value (NPV) 0.98 vs. 0.98; positive likelihood ratio (LR+) 10.18 vs. 9.41; negative likelihood ratio (LR-) 0.09 vs. 0.11. The optimal diagnostic performance was obtained at 3 h using cut-offs cTnI >43 ng/L plus cTnI change from admission ≥18.5 ng/L: sensitivity 0.90, specificity 0.96, PPV 0.81, NPV 0.98, and LR+ 21.54. The area under the receiver operating characteristics (ROC) curve for cTnI whole blood baseline value and absolute change after 3 h curve was 0.93. These data support the clinical usefulness of Minicare cTnI within a 0 h/3 h-blood sampling protocol supported by current guidelines for the evaluation of suspected ACS.
Hornig, Katlin J; Byers, Stacey R; Callan, Robert J; Holt, Timothy; Field, Megan; Han, Hyungchul
2013-08-01
To compare β-hydroxybutyrate (BHB) and glucose concentrations measured with a dual-purpose point-of-care (POC) meter designed for use in humans and a laboratory biochemical analyzer (LBA) to determine whether the POC meter would be reliable for on-farm measurement of blood glucose and BHB concentrations in sheep in various environmental conditions and nutritional states. 36 pregnant mixed-breed ewes involved in a maternal feed restriction study. Blood samples were collected from each sheep at multiple points throughout gestation and lactation to allow for tracking of gradually increasing metabolic hardship. Whole blood glucose and BHB concentrations were measured with the POC meter and compared with serum results obtained with an LBA. 464 samples were collected. Whole blood BHB concentrations measured with the POC meter compared well with LBA results, and error grid analysis showed the POC values were acceptable. Whole blood glucose concentrations measured with the POC meter had more variation, compared with LBA values, over the glucose ranges evaluated. Results of error grid analysis of POC-measured glucose concentrations were not acceptable, indicating errors likely to result in needless treatment with glucose or other supplemental energy sources in normoglycemic sheep. The POC meter was user-friendly and performed well across a wide range of conditions. The meter was adequate for detection of pregnancy toxemia in sheep via whole blood BHB concentration. Results should be interpreted with caution when the POC meter is used to measure blood glucose concentrations.
3D Printing and Assay Development for Point-of-Care Applications
NASA Astrophysics Data System (ADS)
Jagadeesh, Shreesha
Existing centralized labs do not serve patients adequately in remote areas. To enable universal timely healthcare, there is a need to develop low cost, portable systems that can diagnose multiple disease (Point-of-Care (POC) devices). Future POC diagnostics can be more multi-functional if medical device vendors can develop interoperability standards. This thesis developed the following medical diagnostic modules: Plasma from 25 microl blood was extracted through a filter membrane to demonstrate a 3D printed sample preparation module. Sepsis biomarker, C - reactive protein, was quantified through adsorption on nylon beads to demonstrate bead-based assay suitable for 3D printed disposable cartridge module. Finally, a modular fluorescent detection kit was built using 3D printed parts to detect CD4 cells in a disposable cartridge from ChipCare Corp. Due to the modularity enabled by 3D printing technique, the developed units can be easily adapted to detect other diseases.
Cassim, Naseem; Coetzee, Lindi M.; Schnippel, Kathryn; Glencross, Deborah K.
2014-01-01
Background An integrated tiered service delivery model (ITSDM) has been proposed to provide ‘full-coverage’ of CD4 services throughout South Africa. Five tiers are described, defined by testing volumes and number of referring health-facilities. These include: (1) Tier-1/decentralized point-of-care service (POC) in a single site; Tier-2/POC-hub servicing processing <30–40 samples from 8–10 health-clinics; Tier-3/Community laboratories servicing ∼50 health-clinics, processing <150 samples/day; high-volume centralized laboratories (Tier-4 and Tier-5) processing <300 or >600 samples/day and serving >100 or >200 health-clinics, respectively. The objective of this study was to establish costs of existing and ITSDM-tiers 1, 2 and 3 in a remote, under-serviced district in South Africa. Methods Historical health-facility workload volumes from the Pixley-ka-Seme district, and the total volumes of CD4 tests performed by the adjacent district referral CD4 laboratories, linked to locations of all referring clinics and related laboratory-to-result turn-around time (LTR-TAT) data, were extracted from the NHLS Corporate-Data-Warehouse for the period April-2012 to March-2013. Tiers were costed separately (as a cost-per-result) including equipment, staffing, reagents and test consumable costs. A one-way sensitivity analyses provided for changes in reagent price, test volumes and personnel time. Results The lowest cost-per-result was noted for the existing laboratory-based Tiers- 4 and 5 ($6.24 and $5.37 respectively), but with related increased LTR-TAT of >24–48 hours. Full service coverage with TAT <6-hours could be achieved with placement of twenty-seven Tier-1/POC or eight Tier-2/POC-hubs, at a cost-per-result of $32.32 and $15.88 respectively. A single district Tier-3 laboratory also ensured ‘full service coverage’ and <24 hour LTR-TAT for the district at $7.42 per-test. Conclusion Implementing a single Tier-3/community laboratory to extend and improve delivery
Liu, Dan; Li, Xingrui; Zhou, Junkai; Liu, Shibo; Tian, Tian; Song, Yanling; Zhu, Zhi; Zhou, Leiji; Ji, Tianhai; Yang, Chaoyong
2017-10-15
Enzyme-linked immunosorbent assay (ELISA) is a popular laboratory technique for detection of disease-specific protein biomarkers with high specificity and sensitivity. However, ELISA requires labor-intensive and time-consuming procedures with skilled operators and spectroscopic instrumentation. Simplification of the procedures and miniaturization of the devices are crucial for ELISA-based point-of-care (POC) testing in resource-limited settings. Here, we present a fully integrated, instrument-free, low-cost and portable POC platform which integrates the process of ELISA and the distance readout into a single microfluidic chip. Based on manipulation using a permanent magnet, the process is initiated by moving magnetic beads with capture antibody through different aqueous phases containing ELISA reagents to form bead/antibody/antigen/antibody sandwich structure, and finally converts the molecular recognition signal into a highly sensitive distance readout for visual quantitative bioanalysis. Without additional equipment and complicated operations, our integrated ELISA-Chip with distance readout allows ultrasensitive quantitation of disease biomarkers within 2h. The ELISA-Chip method also showed high specificity, good precision and great accuracy. Furthermore, the ELISA-Chip system is highly applicable as a sandwich-based platform for the detection of a variety of protein biomarkers. With the advantages of visual analysis, easy operation, high sensitivity, and low cost, the integrated sample-in-answer-out ELISA-Chip with distance readout shows great potential for quantitative POCT in resource-limited settings. Copyright © 2017. Published by Elsevier B.V.
Mashamba-Thompson, Tivani P; Jama, Ngcwalisa A; Sartorius, Benn; Drain, Paul K; Thompson, Rowan M
2017-01-08
Key stakeholders' involvement is crucial to the sustainability of quality point-of-care (POC) diagnostics services in low-and-middle income countries. The aim of this study was to explore key stakeholder perceptions on the implementation of POC diagnostics in rural primary healthcare (PHC) clinics in South Africa. We conducted a qualitative study encompassing in-depth interviews with multiple key stakeholders of POC diagnostic services for rural and resource-limited PHC clinics. Interviews were digitally recorded and transcribed verbatim prior to thematic content analysis. Thematic content analysis was conducted using themes guided by the World Health Organisation (WHO) quality-ASSURED (Affordable, Sensitive, Specific, User friendly, Rapid and to enable treatment at first visit and Robust, Equipment free and Delivered to those who need it) criteria for POC diagnostic services in resource-limited settings. 11 key stakeholders participated in the study. All stakeholders perceived the main advantage of POC diagnostics as enabling access to healthcare for rural patients. Stakeholders perceived the current POC diagnostic services to have an ability to meet patients' needs, but recommended further improvement of the following areas: research on cost-effectiveness; improved quality management systems; development of affordable POC diagnostic and clinic-based monitoring and evaluation. Key stakeholders of POC diagnostics in rural PHC clinics in South Africa highlighted the need to assess affordability and ensure quality assurance of current services before adopting new POC diagnostics and scaling up current POC diagnostics.
Mashamba-Thompson, Tivani P.; Jama, Ngcwalisa A.; Sartorius, Benn; Drain, Paul K.; Thompson, Rowan M.
2017-01-01
Introduction: Key stakeholders’ involvement is crucial to the sustainability of quality point-of-care (POC) diagnostics services in low-and-middle income countries. The aim of this study was to explore key stakeholder perceptions on the implementation of POC diagnostics in rural primary healthcare (PHC) clinics in South Africa. Method: We conducted a qualitative study encompassing in-depth interviews with multiple key stakeholders of POC diagnostic services for rural and resource-limited PHC clinics. Interviews were digitally recorded and transcribed verbatim prior to thematic content analysis. Thematic content analysis was conducted using themes guided by the World Health Organisation (WHO) quality-ASSURED (Affordable, Sensitive, Specific, User friendly, Rapid and to enable treatment at first visit and Robust, Equipment free and Delivered to those who need it) criteria for POC diagnostic services in resource-limited settings. Results: 11 key stakeholders participated in the study. All stakeholders perceived the main advantage of POC diagnostics as enabling access to healthcare for rural patients. Stakeholders perceived the current POC diagnostic services to have an ability to meet patients’ needs, but recommended further improvement of the following areas: research on cost-effectiveness; improved quality management systems; development of affordable POC diagnostic and clinic-based monitoring and evaluation. Conclusions: Key stakeholders of POC diagnostics in rural PHC clinics in South Africa highlighted the need to assess affordability and ensure quality assurance of current services before adopting new POC diagnostics and scaling up current POC diagnostics. PMID:28075337
Dhawan, Atam P
2016-01-01
Recent advances in biosensors, medical instrumentation, and information processing and communication technologies (ICT) have enabled significant improvements in healthcare. However, these technologies have been mainly applied in clinical environments, such as hospitals and healthcare facilities, under managed care by well-trained and specialized individuals. The global challenge of providing quality healthcare at affordable cost leads to the proposed paradigm of P reventive, Personalized, and Precision Medicine that requires a seamless use of technology and infrastructure support for patients and healthcare providers at point-of-care (POC) locations including homes, semi or pre-clinical facilities, and hospitals. The complexity of the global healthcare challenge necessitates strong collaborative interdisciplinary synergies involving all stakeholder groups including academia, federal research institutions, industry, regulatory agencies, and clinical communities. It is critical to evolve with collaborative efforts on the translation of research to technology development toward clinical validation and potential healthcare applications. This special issue is focused on technology innovation and translational research for POC applications with potential impact in improving global healthcare in the respective areas. Some of these papers were presented at the NIH-IEEE Strategic Conference on Healthcare Innovations and POC Technologies for Precision Medicine (HI-POCT) held at the NIH on November 9-10, 2015. The papers included in the Special Issue provide a spectrum of critical issues and collaborative resources on translational research of advanced POC devices and ICT into global healthcare environment.
2016-01-01
Recent advances in biosensors, medical instrumentation, and information processing and communication technologies (ICT) have enabled significant improvements in healthcare. However, these technologies have been mainly applied in clinical environments, such as hospitals and healthcare facilities, under managed care by well-trained and specialized individuals. The global challenge of providing quality healthcare at affordable cost leads to the proposed paradigm of P reventive, Personalized, and Precision Medicine that requires a seamless use of technology and infrastructure support for patients and healthcare providers at point-of-care (POC) locations including homes, semi or pre-clinical facilities, and hospitals. The complexity of the global healthcare challenge necessitates strong collaborative interdisciplinary synergies involving all stakeholder groups including academia, federal research institutions, industry, regulatory agencies, and clinical communities. It is critical to evolve with collaborative efforts on the translation of research to technology development toward clinical validation and potential healthcare applications. This special issue is focused on technology innovation and translational research for POC applications with potential impact in improving global healthcare in the respective areas. Some of these papers were presented at the NIH-IEEE Strategic Conference on Healthcare Innovations and POC Technologies for Precision Medicine (HI-POCT) held at the NIH on November 9–10, 2015. The papers included in the Special Issue provide a spectrum of critical issues and collaborative resources on translational research of advanced POC devices and ICT into global healthcare environment. PMID:28560119
Yin, Yue-Ping; Chen, Xiang-Sheng; Wei, Wan-Hui; Gong, Kuang-Long; Cao, Wen-Ling; Yong, Gang; Feng, Liang; Huang, Shu-Jie; Wang, Dong-Mei; Han, Yan; Chen, Shao-Chun; Mabey, David; Peeling, Rosanna W.
2013-01-01
Background. Rapid point-of-care (POC) syphilis tests based on simultaneous detection of treponemal and nontreponemal antibodies (dual POC tests) offer the opportunity to increase coverage of syphilis screening and treatment. This study aimed to conduct a multisite performance evaluation of a dual POC syphilis test in China. Methods. Participants were recruited from patients at sexually transmitted infection clinics and high-risk groups in outreach settings in 6 sites in China. Three kinds of specimens (whole blood [WB], fingerprick blood [FB], and blood plasma [BP]) were used for evaluating sensitivity and specificity of the Dual Path Platform (DPP) Syphilis Screen and Confirm test using its treponemal and nontreponemal lines to compare Treponema pallidum particle agglutination (TPPA) assay and toluidine red unheated serum test (TRUST) as reference standards. Results. A total of 3134 specimens (WB 1323, FB 488, and BP 1323) from 1323 individuals were collected. The sensitivities as compared with TPPA were 96.7% for WB, 96.4% for FB, and 94.6% for BP, and the specificities were 99.3%, 99.1%, and 99.6%, respectively. The sensitivities as compared with TRUST were 87.2% for WB, 85.8% for FB, and 88.4% for BP, and the specificities were 94.4%, 96.1%, and 95.0%, respectively. For specimens with a TRUST titer of 1:4 or higher, the sensitivities were 100.0% for WB, 97.8% for FB, and 99.6% for BP. Conclusions. DPP test shows good sensitivity and specificity in detecting treponemal and nontreponemal antibodies in 3 kinds of specimens. It is hoped that this assay can be considered as an alternative in the diagnosis of syphilis, particularly in resource-limited areas. PMID:23132172
Point of Care- A Novel Approach to Periodontal Diagnosis-A Review
Nayak, Prathibha Anand; Rana, Shivendra
2017-01-01
Periodontal disease, one of the prevalent oral diseases, is characterized by gingival inflammation and periodontal tissue destruction. Diagnosing this disease is challenging to the clinicians as the disease process is discontinuous and shows periods of exacerbation and remission. Traditional diagnostic methods basically tells about the past tissue destruction so new diagnostic methods are required which is able to detect the active state of the disease, determine the future progression and also estimates the response to the therapy, thereby helping in the better clinical management of the patient. Both saliva and Gingival crevicular fluid (GCF) are believed to be reliable medium to detect the biomarkers which plays a pivotal role in measuring the disease activity. Keeping these observations in mind rapid chairside tests are developed to diagnose periodontal disease called as Point of Care (POC) diagnostics which simplifies diagnosis and helps in improving the prognosis. This review article highlights about the biomarkers used in the diagnosis and throws light on the various available point of care diagnostic devices. PMID:28969294
Cost Analysis of the STONE Randomized Trial: Can Health Care Costs be Reduced One Test at a Time?
Melnikow, Joy; Xing, Guibo; Cox, Ginger; Leigh, Paul; Mills, Lisa; Miglioretti, Diana L; Moghadassi, Michelle; Smith-Bindman, Rebecca
2016-04-01
Decreasing the use of high-cost tests may reduce health care costs. To compare costs of care for patients presenting to the emergency department (ED) with suspected kidney stones randomized to 1 of 3 initial imaging tests. Patients were randomized to point-of-care ultrasound (POC US, least costly), radiology ultrasound (RAD US), or computed tomography (CT, most costly). Subsequent testing and treatment were the choice of the treating physician. A total of 2759 patients at 15 EDs were randomized to POC US (n=908), RAD US, (n=893), or CT (n=958). Mean age was 40.4 years; 51.8% were male. All medical care documented in the trial database in the 7 days following enrollment was abstracted and coded to estimate costs using national average 2012 Medicare reimbursements. Costs for initial ED care and total 7-day costs were compared using nonparametric bootstrap to account for clustering of patients within medical centers. Initial ED visit costs were modestly lower for patients assigned to RAD US: $423 ($411, $434) compared with patients assigned to CT: $448 ($438, $459) (P<0.0001). Total costs were not significantly different between groups: $1014 ($912, $1129) for POC US, $970 ($878, $1078) for RAD US, and $959 ($870, $1044) for CT. Hospital admissions contributed over 50% of total costs, though only 11% of patients were admitted. Mean total costs (and admission rates) varied substantially by site from $749 to $1239. Assignment to a less costly test had no impact on overall health care costs for ED patients. System-level interventions addressing variation in admission rates from the ED might have greater impact on costs.
Reliable and valid assessment of point-of-care ultrasonography.
Todsen, Tobias; Tolsgaard, Martin Grønnebæk; Olsen, Beth Härstedt; Henriksen, Birthe Merete; Hillingsø, Jens Georg; Konge, Lars; Jensen, Morten Lind; Ringsted, Charlotte
2015-02-01
To explore the reliability and validity of the Objective Structured Assessment of Ultrasound Skills (OSAUS) scale for point-of-care ultrasonography (POC US) performance. POC US is increasingly used by clinicians and is an essential part of the management of acute surgical conditions. However, the quality of performance is highly operator-dependent. Therefore, reliable and valid assessment of trainees' ultrasonography competence is needed to ensure patient safety. Twenty-four physicians, representing novices, intermediates, and experts in POC US, scanned 4 different surgical patient cases in a controlled set-up. All ultrasound examinations were video-recorded and assessed by 2 blinded radiologists using OSAUS. Reliability was examined using generalizability theory. Construct validity was examined by comparing performance scores between the groups and by correlating physicians' OSAUS scores with diagnostic accuracy. The generalizability coefficient was high (0.81) and a D-study demonstrated that 1 assessor and 5 cases would result in similar reliability. The construct validity of the OSAUS scale was supported by a significant difference in the mean scores between the novice group (17.0; SD 8.4) and the intermediate group (30.0; SD 10.1), P = 0.007, as well as between the intermediate group and the expert group (72.9; SD 4.4), P = 0.04, and by a high correlation between OSAUS scores and diagnostic accuracy (Spearman ρ correlation coefficient = 0.76; P < 0.001). This study demonstrates high reliability as well as evidence of construct validity of the OSAUS scale for assessment of POC US competence. Hence, the OSAUS scale may be suitable for both in-training as well as end-of-training assessment.
Gold Nanoparticles for Diagnostics: Advances towards Points of Care
Cordeiro, Mílton; Ferreira Carlos, Fábio; Pedrosa, Pedro; Lopez, António; Baptista, Pedro Viana
2016-01-01
The remarkable physicochemical properties of gold nanoparticles (AuNPs) have prompted developments in the exploration of biomolecular interactions with AuNP-containing systems, in particular for biomedical applications in diagnostics. These systems show great promise in improving sensitivity, ease of operation and portability. Despite this endeavor, most platforms have yet to reach maturity and make their way into clinics or points of care (POC). Here, we present an overview of emerging and available molecular diagnostics using AuNPs for biomedical sensing that are currently being translated to the clinical setting. PMID:27879660
Point-of-care hemoglobin testing for postmortem diagnosis of anemia.
Na, Joo-Young; Park, Ji Hye; Choi, Byung Ha; Kim, Hyung-Seok; Park, Jong-Tae
2018-03-01
An autopsy involves examination of a body using invasive methods such as dissection, and includes various tests using samples procured during dissection. During medicolegal autopsies, the blood carboxyhemoglobin concentration is commonly measured using the AVOXimeter® 4000 as a point-of-care test. When evaluating the body following hypovolemic shock, characteristics such as reduced livor mortis or an anemic appearance of the viscera can be identified, but these observations arequite subjective. Thus, a more objective test is required for the postmortem diagnosis of anemia. In the present study, the AVOXimeter® 4000 was used to investigate the utility of point-of-care hemoglobin testing. Hemoglobin tests were performed in 93 autopsy cases. The AVOXimeter® 4000 and the BC-2800 Auto Hematology Analyzer were used to test identical samples in 29 of these cases. The results of hemoglobin tests performed with these two devices were statistically similar (r = 0.969). The results of hemoglobin tests using postmortem blood were compared with antemortem test results from medical records from 31 cases, and these results were similar. In 13 of 17 cases of death from internal hemorrhage, hemoglobin levels were lower in the cardiac blood than in blood from the affected body cavity, likely due to compensatory changes induced by antemortem hemorrhage. It is concluded that blood hemoglobin testing may be useful as a point-of-care test for diagnosing postmortem anemia.
Guidelines for point-of-care testing: haematology.
Briggs, Carol; Guthrie, David; Hyde, Keith; Mackie, Ian; Parker, Norman; Popek, Mary; Porter, Neil; Stephens, Clare
2008-09-01
This guideline provides a framework for the arrangement of point-of-care testing (POCT) services, previously known as near patient testing (patient self-testing not covered). POCT is defined as any analytical test performed outside the laboratory. Primary users are often non-laboratory healthcare workers. The guidance applies to units within hospitals as well as general practioner surgeries, community clinics and pharmacies. The head of the haematology laboratory or a point of care coordinator must take responsibility for all aspects of the POCT service, including quality and training. Depending on the size and nature of the POCT practice, a local POCT manager may also be required. Equipment selected should have received a successful independent performance evaluation. If an independent evaluation has not been performed the purchaser should assess the device according to the protocol in this document. POCT devices should generate results that are comparable to those of the local laboratory. An accredited external quality assessment programme and internal quality control system must be established. Manufacturers promoting POCT devices designed for non-laboratory sites, e.g. pharmacies, should undertake training and annual competency assessment, perhaps using a web-based system. A diagram to illustrate the stages for the implementation of a POCT service is illustrated.
Harris, A N; Beatty, S S; Estrada, A H; Winter, B; Bohannon, M; Sosa, I; Hanscom, J; Mainville, C A; Gallagher, A E
2017-07-01
N-terminal prohormone of brain natriuretic peptide (NT-proBNP) concentrations may be increased in cats with various cardiac disorders. The point-of-care (POC) ELISA assay uses the same biologic reagents as the quantitative NT-proBNP ELISA. Previous studies have evaluated the sensitivity and specificity of the POC ELISA in cats with cardiac disease. To prospectively evaluate the diagnostic utility of the POC ELISA in a select population of cats. Thirty-eight client-owned cats presented to the University of Florida Cardiology Service for cardiac evaluation. Fifteen apparently healthy cats recruited as part of another study. Physical examination and echocardiography were performed in all cats. The POC ELISA was assessed visually as either positive or negative by a reader blinded to the echocardiographic findings, and results were analyzed relative to quantitative assay results. Twenty-six cats were diagnosed with underlying cardiac disease, and 27 cats were considered free of cardiac disease. Cats with cardiac disease included: 21 with hypertrophic cardiomyopathy, 2 with unclassified cardiomyopathy, 2 with restrictive cardiomyopathy, and 1 with 3rd degree atrioventricular (AV) block. The POC ELISA differentiated cats with cardiac disease with a sensitivity of 65.4% and specificity of 100%. The POC NT-proBNP ELISA performed moderately well in a selected population of cats. A negative test result cannot exclude the presence of underlying cardiac disease, and a positive test result indicates that cardiac disease likely is present, but further diagnostic investigation would be indicated for a definitive diagnosis. Copyright © 2017 The Authors. Journal of Veterinary Internal Medicine published by Wiley Periodicals, Inc. on behalf of the American College of Veterinary Internal Medicine.
Point-of-Care Test Equipment for Flexible Laboratory Automation.
You, Won Suk; Park, Jae Jun; Jin, Sung Moon; Ryew, Sung Moo; Choi, Hyouk Ryeol
2014-08-01
Blood tests are some of the core clinical laboratory tests for diagnosing patients. In hospitals, an automated process called total laboratory automation, which relies on a set of sophisticated equipment, is normally adopted for blood tests. Noting that the total laboratory automation system typically requires a large footprint and significant amount of power, slim and easy-to-move blood test equipment is necessary for specific demands such as emergency departments or small-size local clinics. In this article, we present a point-of-care test system that can provide flexibility and portability with low cost. First, the system components, including a reagent tray, dispensing module, microfluidic disk rotor, and photometry scanner, and their functions are explained. Then, a scheduler algorithm to provide a point-of-care test platform with an efficient test schedule to reduce test time is introduced. Finally, the results of diagnostic tests are presented to evaluate the system. © 2014 Society for Laboratory Automation and Screening.
Ruffinen, Carole Zen; Sabidó, Meritxell; Díaz-Bermúdez, Ximena Pamela; Lacerda, Marcus; Mabey, David; Peeling, Rosanna W; Benzaken, Adele Schwartz
2015-11-05
Point-of-care (POC) screening for HIV and syphilis using rapid testing was implemented in indigenous communities in the triple-border area of the Brazilian Amazon. We describe the context of the early introduction of POC screening, explore hindering and enabling factors for POC implementation, and recommend strategies for feasible, viable, and sustainable syphilis and HIV screening interventions. This was a qualitative study based on grounded theory methodology. Data were collected using in-depth interviews, semi-structured questionnaires, and field observations and were analysed using the framework approach. Qualitative information was complemented by quantitative data for descriptive purposes. An overall high score for vulnerability to acquiring HIV and syphilis was observed among the indigenous communities. Health professionals reported satisfactory rapid testing acceptance, although concerns were raised about the pain of the fingerprick. Counselling-related challenges included ensuring the accuracy of translations, collaborating with translators and communicating positive test results. Over 3 months, 86.7% of the syphilis-positive individuals began treatment, and all of them notified their partners. Accessibility, measured as travel time via the local transportation network, was a barrier to health care access. A lack of gasoline for boats and other transportation was also a hindering factor at all levels of implementation. The recommendations address the preparation phase at the coordination level as well as at the training level. Tools such as strengths, weaknesses, opportunities, and threats (SWOT) analyses; checklists; context-adapted protocols; and fact sheets are very simple methods to facilitate implementation. The findings of this study are important because they may inform the implementation of new health technologies in low-resource national disease control programmes in remote communities.
Allardet-Servent, Jérôme; Lebsir, Melissa; Dubroca, Christian; Fabrigoule, Martine; Jordana, Sylvie; Signouret, Thomas; Castanier, Matthias; Thomas, Guillemette; Soundaravelou, Rettinavelou; Lepidi, Anne; Delapierre, Laurence; Penaranda, Guillaume; Halfon, Philippe; Seghboyan, Jean-Marie
2017-01-01
Rapid detection of abnormal biological values using point-of-care (POC) testing allows clinicians to promptly initiate therapy; however, there are concerns regarding the reliability of POC measurements. We investigated the agreement between the latest generation blood gas analyzer and central laboratory measurements of electrolytes, bicarbonate, hemoglobin, hematocrit, and glucose. 314 paired samples were collected prospectively from 51 critically ill patients. All samples were drawn simultaneously in the morning from an arterial line. BD Vacutainer tubes were analyzed in the central laboratory using Beckman Coulter analyzers (AU 5800 and DxH 800). BD Preset 3 ml heparinized-syringes were analyzed immediately in the ICU using the POC Siemens RAPIDPoint 500 blood gas system. We used CLIA proficiency testing criteria to define acceptable analytical performance and interchangeability. Biases, limits of agreement (±1.96 SD) and coefficients of correlation were respectively: 1.3 (-2.2 to 4.8 mmol/L, r = 0.936) for sodium; 0.2 (-0.2 to 0.6 mmol/L, r = 0.944) for potassium; -0.9 (-3.7 to 2 mmol/L, r = 0.967) for chloride; 0.8 (-1.9 to 3.4 mmol/L, r = 0.968) for bicarbonate; -11 (-30 to 9 mg/dL, r = 0.972) for glucose; -0.8 (-1.4 to -0.2 g/dL, r = 0.985) for hemoglobin; and -1.1 (-2.9 to 0.7%, r = 0.981) for hematocrit. All differences were below CLIA cut-off values, except for hemoglobin. Compared to central Laboratory analyzers, the POC Siemens RAPIDPoint 500 blood gas system satisfied the CLIA criteria of interchangeability for all tested parameters, except for hemoglobin. These results are warranted for our own procedures and devices. Bearing these restrictions, we recommend clinicians to initiate an appropriate therapy based on POC testing without awaiting a control measurement.
Lebsir, Melissa; Dubroca, Christian; Fabrigoule, Martine; Jordana, Sylvie; Signouret, Thomas; Castanier, Matthias; Thomas, Guillemette; Soundaravelou, Rettinavelou; Lepidi, Anne; Delapierre, Laurence; Penaranda, Guillaume; Halfon, Philippe; Seghboyan, Jean-Marie
2017-01-01
Introduction Rapid detection of abnormal biological values using point-of-care (POC) testing allows clinicians to promptly initiate therapy; however, there are concerns regarding the reliability of POC measurements. We investigated the agreement between the latest generation blood gas analyzer and central laboratory measurements of electrolytes, bicarbonate, hemoglobin, hematocrit, and glucose. Methods 314 paired samples were collected prospectively from 51 critically ill patients. All samples were drawn simultaneously in the morning from an arterial line. BD Vacutainer tubes were analyzed in the central laboratory using Beckman Coulter analyzers (AU 5800 and DxH 800). BD Preset 3 ml heparinized-syringes were analyzed immediately in the ICU using the POC Siemens RAPIDPoint 500 blood gas system. We used CLIA proficiency testing criteria to define acceptable analytical performance and interchangeability. Results Biases, limits of agreement (±1.96 SD) and coefficients of correlation were respectively: 1.3 (-2.2 to 4.8 mmol/L, r = 0.936) for sodium; 0.2 (-0.2 to 0.6 mmol/L, r = 0.944) for potassium; -0.9 (-3.7 to 2 mmol/L, r = 0.967) for chloride; 0.8 (-1.9 to 3.4 mmol/L, r = 0.968) for bicarbonate; -11 (-30 to 9 mg/dL, r = 0.972) for glucose; -0.8 (-1.4 to -0.2 g/dL, r = 0.985) for hemoglobin; and -1.1 (-2.9 to 0.7%, r = 0.981) for hematocrit. All differences were below CLIA cut-off values, except for hemoglobin. Conclusions Compared to central Laboratory analyzers, the POC Siemens RAPIDPoint 500 blood gas system satisfied the CLIA criteria of interchangeability for all tested parameters, except for hemoglobin. These results are warranted for our own procedures and devices. Bearing these restrictions, we recommend clinicians to initiate an appropriate therapy based on POC testing without awaiting a control measurement. PMID:28072822
Expansion Mini-Microscopy: An Enabling Alternative in Point-of-Care Diagnostics
Zhang, Yu Shrike; Santiago, Grissel Trujillo-de; Alvarez, Mario Moisés; Schiff, Steven J.; Boyden, Edward S.; Khademhosseini, Ali
2017-01-01
Diagnostics play a significant role in health care. In the developing world and low-resource regions the utility for point-of-care (POC) diagnostics becomes even greater. This need has long been recognized, and diagnostic technology has seen tremendous progress with the development of portable instrumentation such as miniature imagers featuring low complexity and cost. However, such inexpensive devices have not been able to achieve a resolution sufficient for POC detection of pathogens at very small scales, such as single-cell parasites, bacteria, fungi, and viruses. To this end, expansion microscopy (ExM) is a recently developed technique that, by physically expanding preserved biological specimens through a chemical process, enables super-resolution imaging on conventional microscopes and improves imaging resolution of a given microscope without the need to modify the existing microscope hardware. Here we review recent advances in ExM and portable imagers, respectively, and discuss the rational combination of the two technologies, that we term expansion mini-microscopy (ExMM). In ExMM, the physical expansion of a biological sample followed by imaging on a mini-microscope achieves a resolution as high as that attainable by conventional high-end microscopes imaging non-expanded samples, at significant reduction in cost. We believe that this newly developed ExMM technique is likely to find widespread applications in POC diagnostics in resource-limited and remote regions by expanded-scale imaging of biological specimens that are otherwise not resolvable using low-cost imagers. PMID:29062977
Lewis, Nathan A; Towey, Colin; Bruinvels, Georgie; Howatson, Glyn; Pedlar, Charles R
2016-10-01
Exercise causes alterations in redox homeostasis (ARH). Measuring ARH in elite athletes may aid in the identification of training tolerance, fatigued states, and underperformance. To the best of our knowledge, no studies have examined ARH in elite male and female distance runners at sea level. The monitoring of ARH in athletes is hindered by a lack of reliable and repeatable in-the-field testing tools and by the rapid turnaround of results. We examined the effects of various exercise intensities on ARH in healthy (non-over-reached) elite male and female endurance athletes using clinical point-of-care (POC) redox tests, referred to as the free oxygen radical test (FORT) (pro-oxidant) and the free oxygen radical defence (FORD) (antioxidant). Elite male and female endurance athletes (n = 22) completed a discontinuous incremental treadmill protocol at submaximal running speeds and a test to exhaustion. Redox measures were analyzed via blood sampling at rest, warm-up, submaximal exercise, exhaustion, and recovery. FORD was elevated above rest after submaximal and maximal exercise, and recovery (p < 0.05, d = 0.87-1.55), with only maximal exercise and recovery increasing FORT (p < 0.05, d = 0.23-0.32). Overall, a decrease in oxidative stress in response to submaximal and maximal exercise was evident (p < 0.05, d = 0.46). There were no gender differences for ARH (p > 0.05). The velocity at lactate threshold (vLT) correlated with the FORD response at rest, maximal exercise, and recovery (p < 0.05). Using the clinical POC redox test, an absence of oxidative stress after exhaustive exercise is evident in the nonfatigued elite endurance athlete. The blood antioxidant response (FORD) to exercise appears to be related to a key marker of aerobic fitness: vLT.
Li, Ying; Xuan, Jie; Song, Yujun; Qi, Wenjin; He, Bangshun; Wang, Ping; Qin, Lidong
2016-01-26
Point-of-care (POC) testing has the potential to enable rapid, low-cost, and large-scale screening. POC detection of a multiplexed biomarker panel can facilitate the early diagnosis of non-small cell lung cancer (NSCLC) and, thus, may allow for more timely surgical intervention for life-saving treatment. Herein, we report the nanoporous glass (NPG) integrated volumetric bar-chart chip (V-Chip) for POC detection of the three NSCLC biomarkers CEA, CYFRA 21-1, and SCCA, by the naked eye. The 3D nanostructures in the NPG membrane efficiently increase the number of binding sites for antibodies and decrease the diffusion distance between antibody and antigen, enabling the low detection limit and rapid analysis time of the NPG-V-Chip. We utilized the NPG-V-Chip to test the NSCLC biomarker panel and found that the limit of detection can reach 50 pg/mL (10-fold improvement over the original V-Chip), and the total assay time can be decreased from 4 to 0.5 h. We then detected CEA in 21 serum samples from patients with common cancers, and the on-chip results showed good correlation with the clinical results. We further assayed 10 lung cancer samples using the device and confirmed the results obtained using conventional ELISA methods. In summary, the NPG-V-Chip platform has the ability of multiplex, low detection limit, low cost, lack of need for accessory equipment, and rapid analysis time, which may render the V-Chip a useful platform for quantitative POC detection in resource-limited settings and personalized diagnostics.
[Microbiological point of care tests].
Book, Malte; Lehmann, Lutz Eric; Zhang, Xianghong; Stüber, Frank
2010-11-01
It is well known that the early initiation of a specific antiinfective therapy is crucial to reduce the mortality in severe infection. Procedures culturing pathogens are the diagnostic gold standard in such diseases. However, these methods yield results earliest between 24 to 48 hours. Therefore, severe infections such as sepsis need to be treated with an empirical antimicrobial therapy, which is ineffective in an unknown fraction of these patients. Today's microbiological point of care tests are pathogen specific and therefore not appropriate for an infection with a variety of possible pathogens. Molecular nucleic acid diagnostics such as polymerase chain reaction (PCR) allow the identification of pathogens and resistances. These methods are used routinely to speed up the analysis of positive blood cultures. The newest PCR based system allows the identification of the 25 most frequent sepsis pathogens by PCR in parallel without previous culture in less than 6 hours. Thereby, these systems might shorten the time of possibly insufficient antiinfective therapy. However, these extensive tools are not suitable as point of care diagnostics. Miniaturization and automating of the nucleic acid based method is pending, as well as an increase of detectable pathogens and resistance genes by these methods. It is assumed that molecular PCR techniques will have an increasing impact on microbiological diagnostics in the future. © Georg Thieme Verlag Stuttgart · New York.
Towards Detection and Diagnosis of Ebola Virus Disease at Point-of-Care
Kaushik, Ajeet; Tiwari, Sneham; Jayant, Rahul Dev; Marty, Aileen; Nair, Madhavan
2015-01-01
Ebola outbreak-2014 (mainly Zaire strain related Ebola virus) has been declared most widely spread deadly persistent epidemic due to unavailability of rapid diagnostic, detection, and therapeutics. Ebola virus disease (EVD), a severe viral hemorrhagic fever syndrome caused by Ebola virus (EBOV) is transmitted by direct contact with the body fluids of infected person and objects contaminated with virus or infected animals. World Health Organization (WHO) has declared EVD epidemic as public health emergency of international concern with severe global economic burden. At fatal EBOV infection stage, patients usually die before the antibody response. Currently, rapid blood tests to diagnose EBOV infection include the antigen or antibodies capture using ELISA and RNA detection using RT/Q-PCR within 3–10 days after the onset of symptoms. Moreover, few nanotechnology-based colorimetric and paper-based immunoassay methods have been recently reported to detect Ebola virus. Unfortunately, these methods are limited to laboratory only. As state-of-the art (SoA) diagnostics time to confirm Ebola infection, varies from 6 hours to about 3 days, it causes delay in therapeutic approaches. Thus developing a cost-effective, rapid, sensitive, and selective sensor to detect EVD at point-of-care (POC) is certainly worth exploring to establish rapid diagnostics to decide therapeutics. This review highlights SoA of Ebola diagnostics and also a call to develop rapid, selective and sensitive POC detection of EBOV for global health care. We propose that adopting miniaturized electrochemical EBOV immunosensing can detect virus level at pM concentration within ~40 minute compared to 3 days of ELISA test at nM levels. PMID:26319169
Economic Evidence and Point-of-Care Testing
St John, Andrew; Price, Christopher P
2013-01-01
Health economics has been an established feature of the research, policymaking, practice and management in the delivery of healthcare. However its role is increasing as the cost of healthcare begins to drive changes in most healthcare systems. Thus the output from cost effectiveness studies is now being taken into account when making reimbursement decisions, e.g. in Australia and the United Kingdom. Against this background it is also recognised that the health economic tools employed in healthcare, and particularly the output from the use of these tools however, are not always employed in the routine delivery of services. One of the notable consequences of this situation is the poor record of innovation in healthcare with respect to the adoption of new technologies, and the realisation of their benefits. The evidence base for the effectiveness of diagnostic services is well known to be limited, and one consequence of this has been a very limited literature on cost effectiveness. One reason for this situation is undoubtedly the reimbursement strategies employed in laboratory medicine for many years, simplistically based on the complexity of the test procedure, and the delivery as a cost-per-test service. This has proved a disincentive to generate the required evidence, and little effort to generate an integrated investment and disinvestment business case, associated with care pathway changes. Point-of-care testing creates a particularly challenging scenario because, on the one hand, the unit cost-per-test is larger through the loss of the economy of scale offered by automation, whilst it offers the potential of substantial savings through enabling rapid delivery of results, and reduction of facility costs. This is important when many health systems are planning for complete system redesign. We review the literature on economic assessment of point-of-care testing in the context of these developments. PMID:24151342
Jones, Helen; Thomas, James; Newsham, Alex; Downing, Amy; Morris, Eva; Brown, Julia; Velikova, Galina; Forman, David; Wright, Penny
2013-01-01
Background Routine measurement of Patient Reported Outcomes (PROs) linked with clinical data across the patient pathway is increasingly important for informing future care planning. The innovative electronic Patient-reported Outcomes from Cancer Survivors (ePOCS) system was developed to integrate PROs, collected online at specified post-diagnostic time-points, with clinical and treatment data in cancer registries. Objective This study tested the technical and clinical feasibility of ePOCS by running the system with a sample of potentially curable breast, colorectal, and prostate cancer patients in their first 15 months post diagnosis. Methods Patients completed questionnaires comprising multiple Patient Reported Outcome Measures (PROMs) via ePOCS within 6 months (T1), and at 9 (T2) and 15 (T3) months, post diagnosis. Feasibility outcomes included system informatics performance, patient recruitment, retention, representativeness and questionnaire completion (response rate), patient feedback, and administration burden involved in running the system. Results ePOCS ran efficiently with few technical problems. Patient participation was 55.21% (636/1152) overall, although varied by approach mode, and was considerably higher among patients approached face-to-face (61.4%, 490/798) than by telephone (48.8%, 21/43) or letter (41.0%, 125/305). Older and less affluent patients were less likely to join (both P<.001). Most non-consenters (71.1%, 234/329) cited information technology reasons (ie, difficulty using a computer). Questionnaires were fully or partially completed by 85.1% (541/636) of invited participants at T1 (80 questions total), 70.0% (442/631) at T2 (102-108 questions), and 66.3% (414/624) at T3 (148-154 questions), and fully completed at all three time-points by 57.6% (344/597) of participants. Reminders (mainly via email) effectively prompted responses. The PROs were successfully linked with cancer registry data for 100% of patients (N=636). Participant feedback
Marley, Julia V; Oh, May S; Hadgraft, Nyssa; Singleton, Sally; Isaacs, Kim; Atkinson, David
2015-01-01
Objectives To determine if point-of-care (POC) glycated haemoglobin (HbA1c) is sufficiently accurate in real-world remote settings to predict or exclude the diagnosis of diabetes based on laboratory HbA1c measurements. Design Cross-sectional study comparing POC capillary HbA1c results with corresponding venous HbA1c levels measured in a reference laboratory. Participants Aboriginal patients ≥15 years old who were due for diabetes screening at the participating clinics were invited to participate. Two hundred and fifty-five Aboriginal participants were enrolled and 241 were included in the analysis. Setting 6 primary healthcare sites in the remote Kimberley region of Western Australia from September 2011 to November 2013. Main outcome measures Concordance and mean differences between POC capillary blood HbA1c measurement and laboratory measurement of venous blood HbA1c level; POC capillary blood HbA1c equivalence value for screening for diabetes or a high risk of developing diabetes; sensitivity, specificity and positive-predictive value for diagnosing and screening for diabetes; barriers to conducting POC testing. Results Concordance between POC and laboratory results was good (ρ=0.88, p<0.001). The mean difference was −0.15% (95% limits of agreement, −0.67% to 0.36%). POC HbA1c measurements ≥6.5%, 48 mmol/mol had a specificity of 98.2% and sensitivity of 73.7% for laboratory measurements ≥6.5%. The POC equivalence value for screening for diabetes or a high risk of developing diabetes was ≥5.7%, 39 mmol/mol (sensitivity, 91%; specificity, 76.7% for laboratory measurements ≥6.0%, 42 mmol/mol). Staff trained by other clinic staff ‘on the job’ performed as well as people with formal accredited training. Staff reported difficulty in maintaining formal accreditation. Conclusions POC HbA1c testing is sufficiently accurate to be a useful component in screening for, and diagnosing, diabetes in remote communities. Limited local training is
Point-of-Care Detection Devices for Food Safety Monitoring: Proactive Disease Prevention.
Wu, Marie Yung-Chen; Hsu, Min-Yen; Chen, Shih-Jen; Hwang, De-Kuang; Yen, Tzung-Hai; Cheng, Chao-Min
2017-04-01
Food safety has become an increasingly significant public concern in both developed and under-developed nations around the world; it increases morbidity, mortality, human suffering, and economic burden. This Opinion focuses on (i) examining the influence of pathogens and chemicals (e.g., food additives and pesticide residue) on food-borne illnesses, (ii) summarizing food hazards that are present in Asia, and (iii) summarizing the array of current point-of-care (POC) detection devices that have potential applications in food safety monitoring. In addition, we provide insight into global healthcare issues in both developing and under-developed nations with a focus on bridging the gap between food safety issues in the public sector (associated with relevant clinical cases) and the use of POC detection devices for food safety monitoring. Copyright © 2016 Elsevier Ltd. All rights reserved.
Tolan, Nicole V; Wockenfus, Amy M; Koch, Christopher D; Crews, Bridgit O; Dietzen, Dennis J; Karon, Brad S
2017-03-01
Point of care (POC) whole blood lactate testing may facilitate rapid detection of sepsis. We evaluated three POC methods against both plasma lactate comparison methods and a flow-injection mass spectrometric (MS) method. Nova StatStrip, Abbott i-STAT CG4+ and Radiometer ABL90 POC lactate methods were evaluated against the mean of Cobas Integra 400 and Vitros 350 plasma lactate. POC methods were also compared to a flow-injection mass spectrometric assay measuring lactate in ZnSO 4 -precipitated whole blood extracts. Intra- and inter-assay precision was determined using quality control material. Method comparison included specimens from normal donors at rest, after exertion, and after spiking with lactic acid. Intra- and inter-assay coefficient of variation was <5% for i-STAT and ABL90; but ranged from 3.1-8.2% on two StatStrip meters. Mean (±SD) bias between POC and plasma lactate ranged from -0.2±0.9 (i-STAT and ABL90) to -0.4±1.2 (StatStrip) mmol/L. At concentrations >6mmol/L, all POC methods showed proportional negative bias compared to plasma methods; but this bias was not observed when compared to the MS method. Despite proportional negative bias, all POC methods demonstrated acceptable concordance (94-100%) with plasma lactate within the reference interval (<2.3mmol/L) and >4mmol/L, commonly used clinical cut-offs for detection of sepsis. POC lactate methods demonstrate acceptable concordance with plasma lactate across commonly used clinical cut-offs for detection of sepsis. Due to systematic negative bias at higher lactate concentrations, POC and plasma lactate should not be used interchangeably to monitor patients with elevated lactate concentrations. Copyright © 2016 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.
Nerenz, Robert D; Song, Haowei; Gronowski, Ann M
2014-04-01
The predominant hCG variant in urine, hCG β core fragment (hCGβcf), has been demonstrated to cause false-negative results in qualitative point-of-care (POC) hCG devices. This is a major concern for healthcare professionals using POC pregnancy tests. We developed a screening method to evaluate qualitative POC hCG devices for their susceptibility to inhibition by hCGβcf. Using this method, we evaluated the performance of 11 commonly used devices. A wide range of purified hCG and hCGβcf concentrations were mixed and tested on 2 POC devices. By use of those results, a screening method was defined and 9 additional POC devices were evaluated. Two solutions containing (a) 500 pmol/L (171 IU/L) intact hCG with 0 pmol/L hCGβcf and (b) 500 pmol/L intact hCG with 500 000 pmol/L hCGβcf were used to screen all POC devices. The OSOM and Cen-Med Elite devices were found to be most susceptible to false-negative results due to hCGβcf. The BC Icon 20 and the Alere were the least susceptible. The remaining 7 were moderately affected. Devices that gave the strongest signal with hCGβcf alone were those that were least likely to show a hook effect. The screening method put forth here can be used by device users and manufacturers to evaluate POC devices for inhibition by hCGβcf. Of 11 devices evaluated, only 2 have been identified that exhibit minimal to no susceptibility to hCGβcf.
Pashchenko, Oleksandra; Shelby, Tyler; Banerjee, Tuhina; Santra, Santimukul
2018-06-18
Each year, infectious diseases are responsible for millions of deaths, most of which occur in the rural areas of developing countries. Many of the infectious disease diagnostic tools used today require a great deal of time, a laboratory setting, and trained personnel. Due to this, the need for effective point-of-care (POC) diagnostic tools is greatly increasing with an emphasis on affordability, portability, sensitivity, specificity, timeliness, and ease of use. In this Review, we discuss the various diagnostic modalities that have been utilized toward this end and are being further developed to create POC diagnostic technologies, and we focus on potential effectiveness in resource-limited settings. The main modalities discussed herein are optical-, electrochemical-, magnetic-, and colorimetric-based modalities utilized in diagnostic technologies for infectious diseases. Each of these modalities feature pros and cons when considering application in POC settings but, overall, reveal a promising outlook for the future of this field of technological development.
Boaz, Mona; Matas, Zipora; Chaimy, Tova; Landau, Zohar; Bar Dayan, Yosefa; Berlovitz, Yitzhak; Wainstein, Julio
2013-11-01
Acute physiological stress has been shown to impair glucose homeostasis. War is a period of acute psychological stress, and its effect on glucose control is unknown. In this study random point-of-care (POC) glucose levels were measured using an automated, institutional glucometer in hospitalized adult patients prior to versus during the Israeli Pillar of Defense campaign (November 7-10, 2012). Random POC glucose values measured with the institutional blood glucose monitoring system were obtained 1 week prior to the Pillar of Defense campaign (November 7-10, 2012) and compared with values to those obtained during the first 4 days of the war (November 14-17, 2012). In total, 3,573 POC glucose measures were included: 1,865 during the pre-war period and 1,708 during the campaign. POC glucose measures were significantly higher during the war compared with the week preceding the war: 9.7±4.7 versus 9.3±4.2 mmol/L (P=0.02). In a general linear model, period (pre-war vs. during war) persisted as a significant predictor of POC glucose even after controlling for age, sex, and department type (internal medicine vs. surgical). Acute stress, such as a wartime situation, is associated with a significant increase in random blood glucose values in a population of hospitalized adults. Long-term follow-up of the individuals hospitalized during these two periods can reveal differences in morbidity and mortality trends.
NASA Astrophysics Data System (ADS)
Ganesh, Shruthi Vatsyayani
With the advent of microfluidic technologies for molecular diagnostics, a lot of emphasis has been placed on developing diagnostic tools for resource poor regions in the form of Extreme Point of Care devices. To ensure commercial viability of such a device there is a need to develop an accurate sample to answer system, which is robust, portable, isolated yet highly sensitive and cost effective. This need has been a driving force for research involving integration of different microsystems like droplet microfluidics, Compact-disc (CD)microfluidics along with sample preparation and detection modules on a single platform. This work attempts to develop a proof of concept prototype of one such device using existing CD microfluidics tools to generate stable droplets used in point of care diagnostics (POC diagnostics). Apart from using a fairly newer technique for droplet generation and stabilization, the work aims to develop this method focused towards diagnostics for rural healthcare. The motivation for this work is first described with an emphasis on the current need for diagnostic testing in rural health-care and the general guidelines prescribed by WHO for such a sample to answer system. Furthermore, a background on CD and droplet microfluidics is presented to understand the merits and de-merits of each system and the need for integrating the two. This phase of the thesis also includes different methods employed/demonstrated to generate droplets on a spinning platform. An overview on the detection platforms is also presented to understand the challenges involved in building an extreme point of care device. In the third phase of the thesis, general manufacturing techniques and materials used to accomplish this work is presented. Lastly, design trials for droplet generation is presented. The shortcomings of these trials are solved by investigating mechanisms pertaining to design modification and use of agarose based droplet generation to ensure a more robust sample
Fidler, Sarah; Lewis, Heather; Meyerowitz, Jodi; Kuldanek, Kristin; Thornhill, John; Muir, David; Bonnissent, Alice; Timson, Georgina; Frater, John
2017-10-20
There is a global need for HIV viral load point-of-care (PoC) assays to monitor patients receiving antiretroviral therapy. UNICORN was the first study of an off-label protocol using whole blood finger-prick samples tested with and without a simple three minute spin using a clinic-room microcentrifuge. Two PoC assays were evaluated in 40 HIV-positive participants, 20 with detectable and 20 with undetectable plasma viral load (pVL) (<20 copies/ml). Using 100 µl finger-prick blood samples, the Cepheid Xpert HIV-1 Viral Load and HIV-1 Qual cartridges were compared with laboratory pVL assessment (TaqMan, Roche). For participants with undetectable viraemia by TaqMan, there was poor concordance without centrifugation with the TaqMan platform with only 40% 'undetectable' using Xpert VL and 25% 'not detected' using the Qual assay. After a 3 minute spin, 100% of samples were undetectable using either assay, showing full concordance with the TaqMan assay. Defining a lower limit of detection of 1000 copies/ml when including a spin, there was 100% concordance with the TaqMan platform with strong correlation (rho 0.95 and 0.94; p < 0.0001 for both assays). When including a simple microcentrifugation step, finger-prick PoC testing was a quick and accurate approach for assessing HIV viraemia, with excellent concordance with validated laboratory approaches.
Robust ultrasensitive tunneling-FET biosensor for point-of-care diagnostics
Gao, Anran; Lu, Na; Wang, Yuelin; Li, Tie
2016-01-01
For point-of-care (POC) applications, robust, ultrasensitive, small, rapid, low-power, and low-cost sensors are highly desirable. Here, we present a novel biosensor based on a complementary metal oxide semiconductor (CMOS)-compatible silicon nanowire tunneling field-effect transistor (SiNW-TFET). They were fabricated “top-down” with a low-cost anisotropic self-stop etching technique. Notably, the SiNW-TFET device provided strong anti-interference capacity by applying the inherent ambipolarity via both pH and CYFRA21-1 sensing. This offered a more robust and portable general protocol. The specific label-free detection of CYFRA21-1 down to 0.5 fgml−1 or ~12.5 aM was achieved using a highly responsive SiNW-TFET device with a minimum sub-threshold slope (SS) of 37 mVdec−1. Furthermore, real-time measurements highlighted the ability to use clinically relevant samples such as serum. The developed high performance diagnostic system is expected to provide a generic platform for numerous POC applications. PMID:26932158
A Laboratory-Based Evaluation of Four Rapid Point-of-Care Tests for Syphilis
Causer, Louise M.; Kaldor, John M.; Fairley, Christopher K.; Donovan, Basil; Karapanagiotidis, Theo; Leslie, David E.; Robertson, Peter W.; McNulty, Anna M.; Anderson, David; Wand, Handan; Conway, Damian P.; Denham, Ian; Ryan, Claire; Guy, Rebecca J.
2014-01-01
Background Syphilis point-of-care tests may reduce morbidity and ongoing transmission by increasing the proportion of people rapidly treated. Syphilis stage and co-infection with HIV may influence test performance. We evaluated four commercially available syphilis point-of-care devices in a head-to-head comparison using sera from laboratories in Australia. Methods Point-of-care tests were evaluated using sera stored at Sydney and Melbourne laboratories. Sensitivity and specificity were calculated by standard methods, comparing point-of-care results to treponemal immunoassay (IA) reference test results. Additional analyses by clinical syphilis stage, HIV status, and non-treponemal antibody titre were performed. Non-overlapping 95% confidence intervals (CI) were considered statistically significant differences in estimates. Results In total 1203 specimens were tested (736 IA-reactive, 467 IA-nonreactive). Point-of-care test sensitivities were: Determine 97.3%(95%CI:95.8–98.3), Onsite 92.5%(90.3–94.3), DPP 89.8%(87.3–91.9) and Bioline 87.8%(85.1–90.0). Specificities were: Determine 96.4%(94.1–97.8), Onsite 92.5%(90.3–94.3), DPP 98.3%(96.5–99.2), and Bioline 98.5%(96.8–99.3). Sensitivity of the Determine test was 100% for primary and 100% for secondary syphilis. The three other tests had reduced sensitivity among primary (80.4–90.2%) compared to secondary syphilis (94.3–98.6%). No significant differences in sensitivity were observed by HIV status. Test sensitivities were significantly higher among high-RPR titre (RPR≥8) (range: 94.6–99.5%) than RPR non-reactive infections (range: 76.3–92.9%). Conclusions The Determine test had the highest sensitivity overall. All tests were most sensitive among high-RPR titre infections. Point-of-care tests have a role in syphilis control programs however in developed countries with established laboratory infrastructures, the lower sensitivities of some tests observed in primary syphilis suggest these would
Hu, Jie; Cui, Xingye; Gong, Yan; Xu, Xiayu; Gao, Bin; Wen, Ting; Lu, Tian Jian; Xu, Feng
2016-01-01
Cardiovascular diseases (CVDs) are the main causes of morbidity and mortality in the world where about 4 in every 5 CVD deaths happen in low- and middle-income countries (LMICs). Most CVDs are preventable and curable, which is largely dependent on timely and effective interventions, including diagnosis, prognosis and therapeutic monitoring. However, these interventions are high-cost in high income countries and are usually lacking in LMICs. Thanks to the rapid development of microfluidics and nanotechnology, lots of portable analytical devices are developed for detection of CVDs at the point-of-care (POC). In the meantime, smartphone, as a versatile and powerful handheld tool, has been employed not only as a reader for microfluidic assays, but also as an analyzer for physiological indexes. In this review, we present a comprehensive introduction of the current status and potential development direction on POC diagnostics for CVDs. First of all, we introduce some main facts about CVDs and their standard diagnostic procedures and methods. Second, we discuss about both commercially available POC devices and developed prototypes for detection of CVDs via immunoassays. Subsequently, we report the advances in smartphone-based readout for microfluidic assays. Finally, we present some examples using smartphone, individually or combined with other components or devices, for CVD monitoring. We envision an integrated smartphone-based system capable of functioning blood tests, disease examination, and imaging will come in the future. Copyright © 2016 Elsevier Inc. All rights reserved.
Heetderks, William J.; Pavel, Misha; Acharya, Soumyadipta; Akay, Metin; Mairal, Anurag; Wheeler, Bruce; Dacso, Clifford C.; Sunder, T.; Lovell, Nigel; Gerber, Martin; Shah, Milind; Senthilvel, S. G.; Wang, May D.; Bhargava, Balram
2015-01-01
This paper summarizes the panel discussion at the IEEE Engineering in Medicine and Biology Point-of-Care Healthcare Technology Conference (POCHT 2013) held in Bangalore India from Jan 16–18, 2013. Modern medicine has witnessed interdisciplinary technology innovations in healthcare with a continuous growth in life expectancy across the globe. However, there is also a growing global concern on the affordability of rapidly rising healthcare costs. To provide quality healthcare at reasonable costs, there has to be a convergence of preventive, personalized, and precision medicine with the help of technology innovations across the entire spectrum of point-of-care (POC) to critical care at hospitals. The first IEEE EMBS Special Topic POCHT conference held in Bangalore, India provided an international forum with clinicians, healthcare providers, industry experts, innovators, researchers, and students to define clinical needs and technology solutions toward commercialization and translation to clinical applications across different environments and infrastructures. This paper presents a summary of discussions that took place during the keynote presentations, panel discussions, and breakout sessions on needs, challenges, and technology innovations in POC technologies toward improving global healthcare. Also presented is an overview of challenges and trends in developing and developed economies with respect to priority clinical needs, technology innovations in medical devices, translational engineering, information and communication technologies, infrastructure support, and patient and clinician acceptance of POC healthcare technologies. PMID:27170902
Point-of-care technologies for molecular diagnostics using a drop of blood.
Song, Yujun; Huang, Yu-Yen; Liu, Xuewu; Zhang, Xiaojing; Ferrari, Mauro; Qin, Lidong
2014-03-01
Molecular diagnostics is crucial for prevention, identification, and treatment of disease. Traditional technologies for molecular diagnostics using blood are limited to laboratory use because they rely on sample purification and sophisticated instruments, are labor and time intensive, expensive, and require highly trained operators. This review discusses the frontiers of point-of-care (POC) diagnostic technologies using a drop of blood obtained from a finger prick. These technologies, including emerging biotechnologies, nanotechnologies, and microfluidics, hold the potential for rapid, accurate, and inexpensive disease diagnostics. Copyright © 2014 Elsevier Ltd. All rights reserved.
Teaching and evaluating point of care learning with an Internet-based clinical-question portfolio.
Green, Michael L; Reddy, Siddharta G; Holmboe, Eric
2009-01-01
Diplomates in the American Board of Internal Medicine (ABIM) Maintenance of Certification (MOC) program satisfy the self-evaluation of medical knowledge requirement by completing open-book multiple-choice exams. However, this method remains unlikely to affect practice change and often covers content areas not relevant to diplomates' practices. We developed and evaluated an Internet-based point of care (POC) learning portfolio to serve as an alternative. Participants enter information about their clinical questions, including characteristics, information pursuit, application, and practice change. After documenting 20 questions, they reflect upon a summary report and write commitment-to-change statements about their learning strategies. They can link to help screens and medical information resources. We report on the beta test evaluation of the module, completed by 23 internists and 4 internal medicine residents. Participants found the instructions clear and navigated the module without difficulty. The majority preferred the POC portfolio to multiple-choice examinations, citing greater relevance to their practice, guidance in expanding their palette of information resources, opportunity to reflect on their learning needs, and "credit" for self-directed learning related to their patients. Participants entered a total of 543 clinical questions, of which 250 (46%) resulted in a planned practice change. After completing the module, 14 of 27 (52%) participants committed to at least 1 change in their POC learning strategies. Internists found the portfolio valuable, preferred it to multiple-choice examinations, often changed their practice after pursuing clinical questions, and productively reflected on their learning strategies. The ABIM will offer this portfolio as an elective option in MOC.
Toward unstained cytology and complete blood counts at the point of care (Conference Presentation)
NASA Astrophysics Data System (ADS)
Zuluaga, Andres F.; Pierce, Mark C.; MacAulay, Calum E.
2017-02-01
Cytology tests, whether performed on body fluids, aspirates, or scrapings are commonly used to detect, diagnose, and monitor a wide variety of health conditions. Complete blood counts (CBCs) quantify the number of red and white blood cells in a blood volume, as well as the different types of white blood cells. There is a critical unmet need for an instrument that can perform CBCs at the point of care (POC), and there is currently no product in the US that can perform this test at the bedside. We have developed a system that is capable of tomographic images with sub-cellular resolution with consumer-grade broadband (LED) sources and CMOS detectors suitable for POC implementation of CBC tests. The systems consists of cascaded static Michelson and Sagnac interferometers that map phase (encoding depth) and a transverse spatial dimension onto a two-dimensional output plane. Our approach requires a 5 microliter sample, can be performed in 5 minutes or less, and does not require staining or other processing as it relies on intrinsic contrast. We will show results directly imaging and differentiating unstained blood cells using supercontinuum fiber lasers and LEDs as sources and CMOS cameras as sensors. We will also lay out the follow up steps needed, including image segmentation, analysis and classification, to verify performance and advance toward CBCs that can be performed bedside and do not require CLIA-certified laboratories.
Foppen, W; van der Schaaf, I C; Beek, F J A; Mali, W P T M; Fischer, K
2018-05-23
Recurrent joint bleeding is the hallmark of haemophilia. Synovial hypertrophy observed with Magnetic Resonance Imaging (MRI) is associated with an increased risk of future joint bleeding. The aim of this study was to investigate whether point-of-care ultrasound (POC-US) is an accurate alternative for MRI for the detection of early joint changes. In this single centre diagnostic accuracy study, bilateral knees and ankles of haemophilia patients with no or minimal arthropathy on X-rays were scanned using POC-US and 3 Tesla MRI. POC-US was performed by 1 medical doctor, blinded for MRI, according to the "Haemophilia Early Arthropathy Detection with Ultrasound" (HEAD-US) protocol. MRIs were independently scored by 2 radiologists, blinded for clinical data and ultrasound results. Diagnostic accuracy parameters were calculated with 95% confidence intervals (CI). Knees and ankles of 24 haemophilia patients (96 joints), aged 18-34, were studied. Synovial hypertrophy on MRI was observed in 20% of joints. POC-US for synovial tissue was correct (overall accuracy) in 97% (CI: 91-99) with a positive predictive value of 94% (CI: 73-100) and a negative predictive value of 97% (CI: 91-100). The overall accuracy of POC-US for cartilage abnormalities was 91% (CI: 83-96) and for bone surface irregularities 97% (CI: 91-99). POC-US could accurately assess synovial hypertrophy, bone surface irregularities and cartilage abnormalities in haemophilia patients with limited joint disease. As POC-US is an accurate and available alternative for MRI, it can be used for routine evaluation of early joint changes. © 2018 The Authors. Haemophilia published by John Wiley & Sons Ltd.
Point-of-Care Testing: General Aspects.
Ferreira, Carlos E S; Guerra, Joao C C; Slhessarenko, Natasha; Scartezini, Marileia; Franca, Carolina N; Colombini, Marjorie P; Berlitz, Fernando; Machado, Antonia M O; Campana, Gustavo A; Faulhaber, Adriana C L; Galoro, Cesar A; Dias, Claudia M; Shcolnik, Wilson; Martino, Marines D V; Cesar, Katia R; Sumita, Nairo M; Mendes, Maria E; Faulhaber, Marcelo H W; Pinho, Joao R R; Barbosa, Ismar V; Batista, Marcelo C; Khawali, Cristina; Pariz, Vitor M; Andriolo, Adagmar
2018-01-01
Point-of-Care Testing (POCT) has been highlighted in the health care sector in recent decades. On the other hand, due to its low demand, POCT is at a disadvantage compared to conventional equipment, since its cost is inversely proportional to the volume of use. In addition, for the implementation of POCT to succeed, it is essential to rely on the work of a multidisciplinary team. The awareness of health professionals of the importance of each step is perhaps the critical success factor. The trend towards the continuous advancement of the use of POCT and the great potential of its contributions reinforce the need to implement quality management tools, including performance indicators, to ensure their results. This review presents some advantages and disadvantages concerning POCT and the real need to use it. A worldwide call for the availability of easy-to-use health technologies that are increasingly closer to the final user is one of the main reasons for this focus.
Jun, Shelly; Plint, Amy C; Campbell, Sandy M; Curtis, Sarah; Sabir, Kyrellos; Newton, Amanda S
2018-05-01
Cognitive support technologies that support clinical decisions and practices in the emergency department (ED) have the potential to optimize patient care. However, limited uptake by clinicians can prevent successful implementation. A better understanding of acceptance of these technologies from the clinician perspective is needed. We conducted a scoping review to synthesize diverse, emerging evidence on clinicians' acceptance of point-of-care (POC) cognitive support technology in the ED. We systematically searched 10 electronic databases and gray literature published from January 2006 to December 2016. Studies of any design assessing an ED-based POC cognitive support technology were considered eligible for inclusion. Studies were required to report outcome data for technology acceptance. Two reviewers independently screened studies for relevance and quality. Study quality was assessed using the Mixed-Methods Appraisal Tool. A descriptive analysis of the features of POC cognitive support technology for each study is presented, illustrating trends in technology development and evaluation. A thematic analysis of clinician, technical, patient, and organizational factors associated with technology acceptance is also presented. Of the 1,563 references screened for eligibility, 24 met the inclusion criteria and were included in the review. Most studies were published from 2011 onward (88%), scored high for methodologic quality (79%), and examined POC technologies that were novel and newly introduced into the study setting (63%). Physician use of POC technology was the most commonly studied (67%). Technology acceptance was frequently conceptualized and measured by factors related to clinician attitudes and beliefs. Experience with the technology, intention to use, and actual use were also more common outcome measures of technology acceptance. Across studies, perceived usefulness was the most noteworthy factor impacting technology acceptance, and clinicians generally had
Point-of-care test (POCT) INR: hope or illusion?
Dusse, Luci Maria Sant'Ana; Oliveira, Nataly Carvalho; Rios, Danyelle Romana Alves; Marcolino, Milena Soriano
2012-01-01
In the last decade, point-of-care tests were developed to provide rapid generation of test results. These tests have increasingly broad applications. In the area of hemostasis, the international normalized ratio, INR point-of-care test (POCT INR), is the main test of this new proposal. This test has great potential benefit in situations where the quick INR results influences clinical decision making, as in acute ischemic stroke, before surgical procedures and during cardiac surgery. The INR POCT has the potential to be used for self-monitoring of oral anticoagulation in patients under anticoagulant therapy. However, the precision and accuracy of INR POCT still need to be enhanced to increase effectiveness and efficiency of the test. Additionally, the RDC / ANVISA Number 302 makes clear that the POCT testing must be supervised by the technical manager of the Clinical Laboratory in the pre-analytical, analytical and post-analytical. In practice, the Clinical Laboratory does not participate in the implementation of POCT testing or release of the results. Clinicians have high expectation with the incorporation of INR POCT in clinical practice, despite the limitations of this method. These professionals are willing to train the patient to perform the test, but are not legally responsible for the quality of it and are not prepared for the maintenance of equipment. The definition of who is in charge for the test must be one to ensure the quality control.
Phokrai, Phornpun; Karoonboonyanan, Wisansanee; Thanapattarapairoj, Nida; Promkong, Chidchanok; Dulsuk, Adul; Koosakulnirand, Sirikamon; Canovali, Sasha; Indrawattana, Nitaya; Jutrakul, Yaowaruk; Wuthiekanun, Vanaporn; Limmathurotsakul, Direk; Brett, Paul J; Burtnick, Mary N; Lertmemongkolchai, Ganjana; Chantratita, Narisara
2018-05-30
Melioidosis is a fatal infectious disease caused by the environmental bacterium Burkholderia pseudomallei It is highly endemic in Asia and northern Australia but neglected in many other tropical countries. Melioidosis patients have a wide range of clinical manifestations and definitive diagnosis requires bacterial culture which can be time-consuming. A reliable rapid serological tool is greatly needed for disease surveillance and diagnosis. We previously demonstrated by ELISA that a hemolysin-coregulated protein (Hcp1) is a promising target for serodiagnosis of melioidosis. In this study, we have developed a rapid immunochromatography test (ICT) using Hcp1 as the target antigen (Hcp1-ICT). We evaluated this test for specific antibody detection using serum samples obtained from 4 groups of human subjects including : ( i ) 487 culture-confirmed melioidosis patients from four hospitals in northeast Thailand; ( ii ) 202 healthy donors from northeast Thailand; ( iii ) 90 U.S. healthy donors and ( iv ) 207 patients infected with other organisms. Compared to culture results as a gold standard, the sensitivity of ICT for all hospitals was 88.3 %. The specificities for Thai donors and U.S. donors were 86.1 % and 100 % , respectively and for other infections was 91.8 %. The results of the Hcp1-ICT demonstrated 92.4 % agreement with the Hcp1-ELISA with kappa value of 0.829 and is much improved when compared with the current serological method, indirect hemagglutination assay ( IHA ) ( 69.5 % sensitivity and 67.6 % specificity for Thais ). The Hcp1-ICT represents a potential point-of-care ( POC ) test and may be used to replace the IHA for screening of melioidosis in hospitals as well as resource-limited areas. Copyright © 2018 Phokrai et al.
Point-of-care diagnostic tools to detect circulating microRNAS as biomarkers of disease.
Vaca, Luis
2014-05-22
MicroRNAs or miRNAs are a form of small non-coding RNAs (ncRNAs) of 19-22 nucleotides in length in their mature form. miRNAs are transcribed in the nucleus of all cells from large precursors, many of which have several kilobases in length. Originally identified as intracellular modulators of protein synthesis via posttranscriptional gene silencing, more recently it has been found that miRNAs can travel in extracellular human fluids inside specialized vesicles known as exosomes. We will be referring to this miRNAs as circulating microRNAs. More interestingly, the miRNA content inside exosomes changes during pathological events. In the present review we analyze the literature about circulating miRNAs and their possible use as biomarkers. Furthermore, we explore their future in point-of-care (POC) diagnostics and provide an example of a portable POC apparatus useful in the detection of circulating miRNAs.
A new paper-based platform technology for point-of-care diagnostics.
Gerbers, Roman; Foellscher, Wilke; Chen, Hong; Anagnostopoulos, Constantine; Faghri, Mohammad
2014-10-21
Currently, the Lateral flow Immunoassays (LFIAs) are not able to perform complex multi-step immunodetection tests because of their inability to introduce multiple reagents in a controlled manner to the detection area autonomously. In this research, a point-of-care (POC) paper-based lateral flow immunosensor was developed incorporating a novel microfluidic valve technology. Layers of paper and tape were used to create a three-dimensional structure to form the fluidic network. Unlike the existing LFIAs, multiple directional valves are embedded in the test strip layers to control the order and the timing of mixing for the sample and multiple reagents. In this paper, we report a four-valve device which autonomously directs three different fluids to flow sequentially over the detection area. As proof of concept, a three-step alkaline phosphatase based Enzyme-Linked ImmunoSorbent Assay (ELISA) protocol with Rabbit IgG as the model analyte was conducted to prove the suitability of the device for immunoassays. The detection limit of about 4.8 fm was obtained.
Point-of-care testing: applications of 3D printing.
Chan, Ho Nam; Tan, Ming Jun Andrew; Wu, Hongkai
2017-08-08
Point-of-care testing (POCT) devices fulfil a critical need in the modern healthcare ecosystem, enabling the decentralized delivery of imperative clinical strategies in both developed and developing worlds. To achieve diagnostic utility and clinical impact, POCT technologies are immensely dependent on effective translation from academic laboratories out to real-world deployment. However, the current research and development pipeline is highly bottlenecked owing to multiple restraints in material, cost, and complexity of conventionally available fabrication techniques. Recently, 3D printing technology has emerged as a revolutionary, industry-compatible method enabling cost-effective, facile, and rapid manufacturing of objects. This has allowed iterative design-build-test cycles of various things, from microfluidic chips to smartphone interfaces, that are geared towards point-of-care applications. In this review, we focus on highlighting recent works that exploit 3D printing in developing POCT devices, underscoring its utility in all analytical steps. Moreover, we also discuss key advantages of adopting 3D printing in the device development pipeline and identify promising opportunities in 3D printing technology that can benefit global health applications.
Wensil, Ashley M; Smith, Jennifer D; Pound, Melanie W; Herring, Charles
2013-01-01
To compare point-of-care (POC) glycosylated hemoglobin (A1C) and random plasma glucose (RPG) as a POC screening tool for prediabetes and diabetes in migrant farm workers of eastern North Carolina. Prospective, observational, single-center study. Federally qualified community health center in eastern North Carolina, from August to October 2011. Migrant farm workers 18 years or older who resided in a migrant camp in eastern North Carolina. Diabetes screening using POC A1C and RPG via fingerstick followed by venipuncture A1C and basic metabolic panel in individuals with a positive screening. Positive predictive value (PPV) of POC A1C and RPG, incidence of positive screening, incidence of confirmed diagnosis, concordance rate of the screening tools, and correlation between POC A1C and laboratory A1C. 206 workers participated in the screenings; screening identified 39 individuals with a POC A1C greater than 5.7% and 1 individual with both an RPG of 200 mg/dL or more and a POC A1C greater than 5.7%. Of the 39 individuals found to have a positive screening, 24 presented to Carolina Family Health Centers, Inc., for follow-up venipuncture; however, 1 participant did not have a venipuncture A1C, leaving 23 individuals with complete data. Two participants were diagnosed with diabetes and 17 with prediabetes. POC A1C had a PPV of 82.6%; however, the PPV of RPG could not be calculated due to the number of participants lost to follow-up. POC A1C correlated well with laboratory A1C regardless of time to follow-up. POC A1C should be considered for diabetes screening in high-risk populations. If the screening had been performed with RPG alone, 38 individuals would have gone undetected. Early identification of individuals with elevated blood glucose will likely decrease the risk of long-term complications.
Acute pain management efficiency improves with point-of-care handheld electronic billing system.
Fahy, Brenda G
2009-02-01
Technology advances continue to impact patient care and physician workflow. To enable more efficient performance of billing activities, a point-of-care (POC) handheld computer technology replaced a paper-based system on an acute pain management service. Using a handheld personal digital assistant (PDA) and software from MDeverywhere (MDe, MDeverywhere, Long Island, NY), we performed a 1-yr prospective observational study of an anesthesiology acute pain management service billings and collections. Seventeen anesthesiologists providing billable acute pain services were trained and entered their charges on a PDA. Twelve months of data, just before electronic implementation (pre-elec), were compared to a 12-m period after implementation (post-elec). The total charges were 4883 for 890 patients pre-elec and 5368 for 1128 patients post-elec. With adoption of handheld billing, the charge lag days decreased from 29.3 to 7.0 (P < 0.001). The days in accounts receivable trended downward from 59.9 to 51.1 (P = 0.031). The average number of charge lag days decreased significantly with month (P = 0.0002). The net collection rate increased from 37.4% pre-elec to 40.3% post-elec (P < 0.001). The return on investment was 1.18 fold (118%). Implementation of POC electronic billing using PDAs to replace a paper-based billing system improved the collection rate and decreased the number of charge lag days with a positive return on investment. The handheld PDA billing system provided POC support for physicians during their daily clinical (e.g., patient locations, rounding lists) and billing activities, improving workflow.
Type of Evidence Behind Point-of-Care Clinical Information Products: A Bibliometric Analysis
2011-01-01
Background Point-of-care (POC) products are widely used as information reference tools in the clinical setting. Although usability, scope of coverage, ability to answer clinical questions, and impact on health outcomes have been studied, no comparative analysis of the characteristics of the references, the evidence for the content, in POC products is available. Objective The objective of this study was to compare the type of evidence behind five POC clinical information products. Methods This study is a comparative bibliometric analysis of references cited in monographs in POC products. Five commonly used products served as subjects for the study: ACP PIER, Clinical Evidence, DynaMed, FirstCONSULT, and UpToDate. The four clinical topics examined to identify content in the products were asthma, hypertension, hyperlipidemia, and carbon monoxide poisoning. Four indicators were measured: distribution of citations, type of evidence, product currency, and citation overlap. The type of evidence was determined based primarily on the publication type found in the MEDLINE bibliographic record, as well as the Medical Subject Headings (MeSH), both assigned by the US National Library of Medicine. MeSH is the controlled vocabulary used for indexing articles in MEDLINE/PubMed. Results FirstCONSULT had the greatest proportion of references with higher levels of evidence publication types such as systematic review and randomized controlled trial (137/153, 89.5%), although it contained the lowest total number of references (153/2330, 6.6%). DynaMed had the largest total number of references (1131/2330, 48.5%) and the largest proportion of current (2007-2009) references (170/1131, 15%). The distribution of references cited for each topic varied between products. For example, asthma had the most references listed in DynaMed, Clinical Evidence, and FirstCONSULT, while hypertension had the most references in UpToDate and ACP PIER. An unexpected finding was that the rate of citation
Sabath, Bruce F; Singh, Gurkeerat
2016-01-01
Point-of-care (POC) ultrasonography is considered fundamental in emergency medicine training and recently has become a milestone in critical care fellowship programs as well. Currently, there is no such standard requirement for internal medicine residency programs in the United States. We present a new case and briefly review another case at our institution - a community hospital - in which internal medicine house staff trained in ultrasonography were able to uncover unexpected and critical diagnoses that significantly changed patient care and outcomes. We also review the growing evidence of the application of ultrasound in the diagnosis of a myriad of conditions encountered in general internal medicine as well as the mounting data on the ability of internal medicine residents to apply this technology accurately at the bedside. We advocate that the literature has sufficiently established the role of POC ultrasonography in general internal medicine that there should no longer be any delay in giving this an official place in the development of internal medicine trainees. This may be particularly useful in the community hospital setting where 24-h echocardiography or other sonography may not be readily available.
Mashamba-Thompson, T P; Sartorius, B; Thabane, L; Shi, C X; Drain, P K
2016-01-01
Introduction Studies indicate substandard diagnostic care, delayed and missed diagnosis as some of the contributing factors to maternal mortality. The clinical impact of point-of-care (POC) diagnostics has been shown in the monitoring and treatment of a variety of infectious diseases, including HIV/AIDS and tuberculosis. The objective of this systematic review is to investigate the impact of POC diagnostics on maternal outcomes for HIV-infected women. Methods We will conduct a systematic review to evaluate the impact of POC diagnostics for improving desired healthcare outcomes for HIV-infected women. The search strategy will involve electronic databases including: Cochrane Infectious Disease Group Specialised Register; Cochrane Central Register of Control Trials, published in The Cochrane Library; PubMed; EBSCOhost and LILACS. The studies will be mapped in 2 stages: stage 1 will map studies descriptively by focus and method; stage 2 will involve additional inclusion criteria, quality assessment and data extraction undertaken by 2 reviewers in parallel. Evidence will be synthesised using relevant systematic research tools: meta-analysis and subgroup analysis will be conducted using RevMan and Stata 13 will be used for meta-regressions. We will follow recommendations described in the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) statement and the Cochrane Handbook for Intervention Reviews. Ethics and dissemination We anticipate finding a large number of studies on POC diagnostic interventions on maternal outcomes in HIV-infected women, which, once summarised, will be useful to guide future diagnostic interventions. The protocol for the systematic review has been registered in PROSPERO. The study will be disseminated electronically and in print. It will also be presented to conferences related to HIV/AIDS, POC diagnostics and maternal health. Trial registration number PROSPERO CRD42014015439. PMID:26817633
Assessing the performance of handheld glucose testing for critical care.
Kost, Gerald J; Tran, Nam K; Louie, Richard F; Gentile, Nicole L; Abad, Victor J
2008-12-01
We assessed the performance of a point-of-care (POC) glucose meter system (GMS) with multitasking test strip by using the locally-smoothed (LS) median absolute difference (MAD) curve method in conjunction with a modified Bland-Altman difference plot and superimposed International Organization for Standardization (ISO) 15197 tolerance bands. We analyzed performance for tight glycemic control (TGC). A modified glucose oxidase enzyme with a multilayer-gold, multielectrode, four-well test strip (StatStriptrade mark, NOVA Biomedical, Waltham, MA) was used. There was no test strip calibration code. Pragmatic comparison was done of GMS results versus paired plasma glucose measurements from chemistry analyzers in clinical laboratories. Venous samples (n = 1,703) were analyzed at 35 hospitals that used 20 types of chemistry analyzers. Erroneous results were identified using the Bland-Altman plot and ISO 15197 criteria. Discrepant values were analyzed for the TGC interval of 80-110 mg/dL. The GMS met ISO 15197 guidelines; 98.6% (410 of 416) of observations were within tolerance for glucose <75 mg/dL, and for > or =75 mg/dL, 100% were within tolerance. Paired differences (handheld minus reference) averaged -2.2 (SD 9.8) mg/dL; the median was -1 (range, -96 to 45) mg/dL. LS MAD curve analysis revealed satisfactory performance below 186 mg/dL; above 186 mg/dL, the recommended error tolerance limit (5 mg/dL) was not met. No discrepant values appeared. All points fell in Clarke Error Grid zone A. Linear regression showed y = 1.018x - 0.716 mg/dL, and r2 = 0.995. LS MAD curves draw on human ability to discriminate performance visually. LS MAD curve and ISO 15197 performance were acceptable for TGC. POC and reference glucose calibration should be harmonized and standardized.
Genoway, Shyla; Caine, Vera; Singh, Ameeta E; Estefan, Andrew
2016-01-01
With a call to increase the accessibility of HIV testing, point-of-care testing for HIV is being readily adopted, but little attention has been paid to the experiences of people being tested at HIV point-of-care sites. Some testing environments, such as bathhouses, promote testing for HIV in higher-risk groups. In this narrative inquiry study we explored the experiences of people testing positive for HIV through point-of-care while at a bathhouse. Three narrative threads for reconsidering the practice were identified: (a) seeing complexities, understanding testing decisions in relation to time, place, and social context; (b) recognizing the impact and significance of secret and silent stories; and (c) tentative and tension-filled connections to care. It is important to understand testing experiences across time, place, and in diverse social contexts. These experiences are embedded within the larger life histories of people and raise questions about adequate support, follow-up, and counseling. Copyright © 2016 Association of Nurses in AIDS Care. Published by Elsevier Inc. All rights reserved.
Dou, Maowei; Lopez, Juan; Rios, Misael; Garcia, Oscar; Xiao, Chuan; Eastman, Michael
2016-01-01
A cost-effective battery-powered spectrophotometric system (BASS) was developed for quantitative point-of-care (POC) analysis on a microfluidic chip. By using methylene blue as a model analyte, we first compared the performance of the BASS with a commercial spectrophotometric system, and further applied the BASS for loop-mediated isothermal amplification (LAMP) detection and subsequent quantitative nucleic acid analysis which exhibited a comparable limit of detection to that of Nanodrop. Compared to the commercial spectrophotometric system, our spectrophotometric system is lower-cost, consumes less reagents, and has a higher detection sensitivity. Most importantly, it does not rely on external power supplies. All these features make our spectrophotometric system highly suitable for a variety of POC analyses, such as field detection. PMID:27143408
Fanikos, John; Erickson, Abbie; Munz, Kristin E; Sanborn, Mike D; Ludwig, Brad C; Van Hassel, Tom
2007-10-01
The use of ready-to-use (RTU) and point-of-care (POC) activated parenteral products and their storage in automated dispensing cabinets (ADCs) in U.S. hospitals were evaluated. A survey on the use of RTU and POC activated parenteral products, including storage and dispensing of the products, was developed and sent electronically to hospital pharmacy administrators. Survey respondents were identified using the American Society of Health-System Pharmacists' member database. Of the 4070 surveys sent, 965 (23.7%) were completed and returned. Most pharmacy administrators (94.7%) reported that their institution used some form of RTU and POC activated parenteral product, with 74% using ADCs to dispense these products. Efficiency was the most common reason cited for storage of RTU and POC activated products in ADCs. Facilities varied on reasons for not implementing this technology, with 47 facilities citing implementation costs, limited number of RTU and POC activated products on the hospital's formulary, lack of available pediatric formulations, and safety concerns as the main reasons. More than half of respondents noted space limitations as the greatest challenge to adding RTU and POC activated products to ADCs. Nearly three fourths of survey respondents reported using RTU and POC products in conjunction with ADCs; however, the approach to including these products in ADCs varied based on the characteristics, policies, and preferences of the individual facility. Advantages of RTU and POC products identified by respondents included enhanced safety benefits, increased dispensing efficiency, cost avoidance due to reduced waste, and improved compliance with federal and state regulations.
Development of a digital microfluidic platform for point of care testing
Sista, Ramakrishna; Hua, Zhishan; Thwar, Prasanna; Sudarsan, Arjun; Srinivasan, Vijay; Eckhardt, Allen; Pollack, Michael; Pamula, Vamsee
2009-01-01
Point of care testing is playing an increasingly important role in improving the clinical outcome in health care management. The salient features of a point of care device are quick results, integrated sample preparation and processing, small sample volumes, portability, multifunctionality and low cost. In this paper, we demonstrate some of these salient features utilizing an electrowetting-based Digital Microfluidic platform. We demonstrate the performance of magnetic bead-based immunoassays (cardiac troponin I) on a digital microfluidic cartridge in less than 8 minutes using whole blood samples. Using the same microfluidic cartridge, a 40-cycle real-time polymerase chain reaction was performed within 12 minutes by shuttling a droplet between two thermal zones. We further demonstrate, on the same cartridge, the capability to perform sample preparation for bacterial and fungal infectious disease pathogens (methicillin-resistance Staphylococcus aureus and Candida albicans) and for human genomic DNA using magnetic beads. In addition to rapid results and integrated sample preparation, electrowetting-based digital microfluidic instruments are highly portable because fluid pumping is performed electronically. All the digital microfluidic chips presented here were fabricated on printed circuit boards utilizing mass production techniques that keep the cost of the chip low. Due to the modularity and scalability afforded by digital microfluidics, multifunctional testing capability, such as combinations within and between immunoassays, DNA amplification, and enzymatic assays, can be brought to the point of care at a relatively low cost because a single chip can be configured in software for different assays required along the path of care. PMID:19023472
Gijzen, Karlijn; Moolenaar, David L J; Weusten, Jos J A M; Pluim, Hendrik J; Demir, Ayse Y
2012-11-01
Implementation of tight glycemic control (TGC) and avoidance of hypoglycemia in intensive care unit (ICU) patients require frequent analysis of blood glucose. This can be achieved by accurate point-of-care (POC) hospital-use glucose meters. In this study one home-use and four different hospital-use POC glucose meters were evaluated in critically ill ICU patients. All patients (n = 80) requiring TGC were included in this study. For each patient three to six glucose measurements (n = 390) were performed. Blood glucose was determined by four hospital-use POC glucose meters, Roche Accu-Check Inform II System, HemoCue Glu201DM, Nova StatStrip, Abbott Precision Xceed Pro, and one home-use POC glucose meter, Menarini GlucoCard Memory PC. The criteria described in ISO 15197, Dutch TNO quality guideline and in NACB/ADA-2011 were applied in the comparisons. According to the ISO 15197, the percentages of the measured values that fulfilled the criterion were 99.5% by Roche, 95.1% by HemoCue, 91.0% by Nova, 96.6% by Abbott, and 63.3% by Menarini. According to the TNO quality guideline these percentages were 96.1% , 91.0% , 81.8% , 94.2% , and 47.7% , respectively. Application of the NACB/ADA guideline resulted in percentages of 95.6%, 89.2%, 77.9%, 93.4%, and 45.4%, respectively. When ISO 15197 was applied, Roche, HemoCue and Abbott fulfilled the criterion in this patient population, whereas Nova and Menarini did not. However, when TNO quality guideline and NACB/ADA 2011 guideline were applied only Roche fulfilled the criteria.
Martínez Lomakin, Felipe; Tobar, Catalina
2014-12-01
Contrast-induced nephropathy (CIN) is a common event in hospitals, with reported incidences ranging from 1 to 30%. Patients with underlying kidney disease have an increased risk of developing CIN. Point-of-care (POC) creatinine devices are handheld devices capable of providing quantitative data on a patient's kidney function that could be useful in stratifying preventive measures. This overview aims to synthesize the current evidence on diagnostic accuracy and clinical utility of POC creatinine devices in detecting patients at risk of CIN. Five databases were searched for diagnostic accuracy studies or clinical trials that evaluated the usefulness of POC devices in detecting patients at risk of CIN. Selected articles were critically appraised to assess their individual risk of bias by the use of standard criteria; 13 studies were found that addressed the diagnostic accuracy or clinical utility of POC creatinine devices. Most studies incurred a moderate to high risk of bias. Overall concordance between POC devices and reference standards (clinical laboratory procedures) was found to be moderate, with 95% limits of agreement often lying between -35.4 and +35.4 µmol/L (-0.4 and +0.4 mg/dL). Concordance was shown to decrease with worsening kidney function. Data on the clinical utility of these devices were limited, but a significant reduction in time to diagnosis was reported in two studies. Overall, POC creatinine devices showed a moderate concordance with standard clinical laboratory creatinine measurements. Several biases could have induced optimism in these estimations. Results obtained from these devices may be unreliable in cases of severe kidney failure. Randomized trials are needed to address the clinical utility of these devices.
Nature of POC transport in a mangrove ecosystem: A carbon stable isotopic study
NASA Astrophysics Data System (ADS)
Rezende, C. E.; Lacerda, L. D.; Ovall, A. R. C.; Silva, C. A. R.; Martinelli, L. A.
1990-06-01
The isotopic composition of particulate organic carbon (POC) was studied during five tidal cycles in a mangrove creek of Sepetiba Bay, Rio de Janeiro, Brazil. The results show that a mixture of organic carbon from mangrove and marine origins is always present in the creek. Mean mangrove contribution to the POC varied from 16% to 100% and was dependent on tidal amplitude. The results suggest that oceanic carbon can be an important component of carbon balance in mangrove ecosystems. Therefore, earlier carbon balance studies from mangroves which did not include measurements of carbon isotopic composition should be interpreted with care.
Multivalent Nanoparticle Networks Enable Point of Care Detection of Human Phospholipase-A2 in Serum
Burnapp, Mark; Bentham, Andrew; Hillier, David; Zabron, Abigail; Khan, Shahid; Tyreman, Matthew; Stevens, Molly M.
2017-01-01
A rapid and highly sensitive point of care (PoC) lateral flow assay for phospholipase-A2 (PLA2) is demonstrated in serum through the enzyme-triggered release of a new class of biotinylated multi-armed polymers from a liposome substrate. Signal from the enzyme activity is generated by the adhesion of polystreptavidin coated gold nanoparticle networks to the lateral flow device, which leads to the appearance of a red test line due to the localised surface plasmon resonance (LSPR) effect of the gold. The use of a liposome as the enzyme substrate and multivalent linkers to link the nanoparticles leads to amplification of the signal as the cleavage of a small amount of lipids is able to release a large amount of polymer linker and adhesion of an even larger amount of gold nanoparticles. By optimising the molecular weight and multivalency of these biotinylated polymer linkers the sensitivity of the device can be tuned to enable naked-eye detection of 1 nM human-PLA2 in serum within 10 minutes. This high sensitivity enabled the correct diagnosis of pancreatitis in diseased clinical samples against a set of healthy controls using PLA2 activity in a point of care device for the first time. PMID:25756526
Scenario-Based Assessment of User Needs for Point-of-Care Robots.
Lee, Hyeong Suk; Kim, Jeongeun
2018-01-01
This study aimed to derive specific user requirements and barriers in a real medical environment to define the essential elements and functions of two types of point-of-care (POC) robot: a telepresence robot as a tool for teleconsultation, and a bedside robot to provide emotional care for patients. An analysis of user requirements was conducted; user needs were gathered and identified, and detailed, realistic scenarios were created. The prototype robots were demonstrated in physical environments for envisioning and evaluation. In all, three nurses and three clinicians participated as evaluators to observe the demonstrations and evaluate the robot systems. The evaluators were given a brief explanation of each scene and the robots' functionality. Four major functions of the teleconsultation robot were defined and tested in the demonstration. In addition, four major functions of the bedside robot were evaluated. Among the desired functions for a teleconsultation robot, medical information delivery and communication had high priority. For a bedside robot, patient support, patient monitoring, and healthcare provider support were the desired functions. The evaluators reported that the teleconsultation robot can increase support from and access to specialists and resources. They mentioned that the bedside robot can improve the quality of hospital life. Problems identified in the demonstration were those of space conflict, communication errors, and safety issues. Incorporating this technology into healthcare services will enhance communication and teamwork skills across distances and thereby facilitate teamwork. However, repeated tests will be needed to evaluate and ensure improved performance.
Taylor, Kathryn S; Verbakel, Jan Y; Feakins, Benjamin G; Price, Christopher P; Perera, Rafael; Bankhead, Clare; Plüddemann, Annette
2018-05-21
To assess the diagnostic accuracy of point-of-care natriuretic peptide tests in patients with chronic heart failure, with a focus on the ambulatory care setting. Systematic review and meta-analysis. Ovid Medline, Cochrane Central Register of Controlled Trials, Cochrane Database of Systematic Reviews, Database of Abstracts of Reviews of Effects, Embase, Health Technology Assessment Database, Science Citation Index, and Conference Proceedings Citation Index until 31 March 2017. Eligible studies evaluated point-of-care natriuretic peptide testing (B-type natriuretic peptide (BNP) or N terminal fragment pro B-type natriuretic peptide (NTproBNP)) against any relevant reference standard, including echocardiography, clinical examination, or combinations of these, in humans. Studies were excluded if reported data were insufficient to construct 2×2 tables. No language restrictions were applied. 42 publications of 39 individual studies met the inclusion criteria and 40 publications of 37 studies were included in the analysis. Of the 37 studies, 30 evaluated BNP point-of-care testing and seven evaluated NTproBNP testing. 15 studies were done in ambulatory care settings in populations with a low prevalence of chronic heart failure. Five studies were done in primary care. At thresholds >100 pg/mL, the sensitivity of BNP, measured with the point-of-care index device Triage, was generally high and was 0.95 (95% confidence interval 0.90 to 0.98) at 100 pg/mL. At thresholds <100 pg/mL, sensitivity ranged from 0.46 to 0.97 and specificity from 0.31 to 0.98. Primary care studies that used NTproBNP testing reported a sensitivity of 0.99 (0.57 to 1.00) and specificity of 0.60 (0.44 to 0.74) at 135 pg/mL. No statistically significant difference in diagnostic accuracy was found between point-of-care BNP and NTproBNP tests. Given the lack of studies in primary care, the paucity of NTproBNP data, and potential methodological limitations in these studies, large scale trials in primary care
Kim, Changsun; Kim, Hansol
2017-12-09
Comparing a point-of-care (POC) test using the capillary blood obtained from skin puncture with conventional laboratory tests. In this study, which was conducted at the emergency department of a tertiary care hospital in April-July 2017, 232 patients were enrolled, and three types of blood samples (capillary blood from skin puncture, arterial and venous blood from blood vessel puncture) were simultaneously collected. Each blood sample was analyzed using a POC analyzer (epoc® system, USA), an arterial blood gas analyzer (pHOx®Ultra, Nova biomedical, USA) and venous blood analyzers (AU5800, DxH2401, Beckman Coulter, USA). Twelve parameters were compared between the epoc and reference analyzers, with an equivalence test, Bland-Altman plot analysis and linear regression employed to show the agreement or correlation between the two methods. The pH, HCO 3 , Ca 2+ , Na + , K + , Cl - , glucose, Hb and Hct measured by the epoc were equivalent to the reference values (95% confidence interval of mean difference within the range of the agreement target) with clinically inconsequential mean differences and narrow limits of agreement. All of them, except pH, had clinically acceptable agreements between the two methods (results within target value ≥80%). Of the remaining three parameters (pCO 2, pO 2 and lactate), the epoc pCO 2 and lactate values were highly correlated with the reference device values, whereas pO 2 was not. (pCO 2 : R 2 =0.824, y=-1.411+0.877·x; lactate: R 2 =0.902, y=-0.544+0.966·x; pO 2 : R 2 =0.037, y=61.6+0.431·x). Most parameters, except only pO 2 , measured by the epoc were equivalent to or correlated with those from the reference method. Copyright © 2017 Elsevier Inc. All rights reserved.
Leal Yepes, F A; Nydam, D V; Heuwieser, W; Mann, S
2018-04-25
The use of point-of-care (POC) devices to measure blood metabolites, such as β-hydroxybutyrate (BHB), on farm have become an important diagnostic and screening tool in the modern dairy industry. The POC devices allow for immediate decision making and are often more economical than the use of laboratory-based methods; however, precision and accuracy may be lower when measurements are performed in an uncontrolled environment. Ideally, the advantages of the POC devices and the standardized laboratory environment could be combined when measuring samples that do not require an immediate result-for example, in research applications or when immediate intervention is not the goal. The objective of this study was to compare the capability of 2 POC devices (TaiDoc, Pharmadoc, Lübeck, Germany; Precision Xtra, Abbott Diabetes Care, Abingdon, UK) to measure BHB concentrations either at room temperature (RT; 20-22°C) or at 37°C compared with the gold standard test in stored plasma samples. Whole blood from multiparous Holstein dairy cows (n = 113) was sampled from the coccygeal vessels between 28 d before expected calving and 42 DIM. Whole-blood BHB concentrations were determined cow-side using the TaiDoc POC device. Plasma was separated within 1 h of collection and stored until analysis. A subset of stored plasma samples (n = 100) consisting of 1 sample per animal was chosen retrospectively based on the BHB concentrations in whole blood within the range of 0.2 to 4.0 mmol/L. The samples were analyzed for BHB plasma concentration using an automated chemistry analyzer (Hitachi 917, Hitachi, Tokyo, Japan), which was considered the gold standard. On the same day, the samples were also measured with the 2 POC devices, with samples either at RT or heated up to 37°C. Our study showed high Spearman correlation coefficients (>0.99) using either device and with samples at both temperatures compared with the gold standard. Passing-Bablok regression revealed a very strong correlation
Stolz, Lori A; Muruganandan, Krithika M; Bisanzo, Mark C; Sebikali, Mugisha J; Dreifuss, Bradley A; Hammerstedt, Heather S; Nelson, Sara W; Nayabale, Irene; Adhikari, Srikar; Shah, Sachita P
2015-08-01
To describe the outcomes and curriculum components of an educational programme to train non-physician clinicians working in a rural, Ugandan emergency department in the use of POC ultrasound. The use of point-of-care ultrasound was taught to emergency care providers through lectures, bedsides teaching and hands-on practical sessions. Lectures were tailored to care providers' knowledge base and available therapeutic means. Every ultrasound examination performed by these providers was recorded over 4.5 years. Findings of these examinations were categorised as positive, negative, indeterminate or procedural. Other radiologic studies ordered over this same time period were also recorded. A total of 22,639 patients were evaluated in the emergency department by emergency care providers, and 2185 point-of-care ultrasound examinations were performed on 1886 patients. Most commonly used were the focused assessment with sonography in trauma examination (53.3%) and echocardiography (16.4%). Point-of-care ultrasound studies were performed more frequently than radiology department-performed studies. Positive findings were documented in 46% of all examinations. We describe a novel curriculum for point-of-care ultrasound education of non-physician emergency practitioners in a resource-limited setting. These non-physician clinicians integrated ultrasound into clinical practice and utilised this imaging modality more frequently than traditional radiology department imaging with a large proportion of positive findings. © 2015 John Wiley & Sons Ltd.
Peters, Catharina M; Schouwenaars, Francesca M; Haagsma, Ellen; Evenhuis, Heleen M; Echteld, Michael A
2013-01-01
Background Excessive prescribing of antibiotics in patients with lower respiratory tract infections (LRTIs) is common in the general population. Due to communication difficulties, it is hypothesised that prescriptions are even more commonplace in the primary care of individuals with intellectual disabilities. Point-of-care C-reactive protein (POC-CRP) testing might lead to more efficient prescribing of antibiotics. Aim To evaluate the effect of POC-CRP testing on antibiotic prescriptions for LRTIs by physicians specialising in the care of individuals with intellectual disabilities. Design and setting A prospective case-control study in four care centres for individuals with intellectual disabilities in The Netherlands. Method Between 27 October 2010 and 27 October 2011, a prospective efficiency study was performed with a base population of 1472 individuals. This population consisted of 882 individuals in whom POC-CRP tests were used and a control group (n = 590) in whom no POC-CRP test was performed. Results Of the 48 patients in the control group who were diagnosed as having an LRTI, 43 (90%) received antibiotics, compared with 59 out of the 144 patients (41%) in the case group (OR = 12.0; 95% CI = 4.1–35.3). No significant differences in outcome were found between both groups during a follow-up period of 1 month. Conclusion This study shows that the use of POC-CRP testing in patients with intellectual disabilities and LRTIs can lead to a significant reduction in antibiotic prescriptions, with no significant differences in outcome during follow-up. PMID:23643230
Gaw, James R; Crowley, Steven; Monagle, Paul; Jones, Sophie; Newall, Fiona
2013-07-01
The use of point-of-care (POC) devices within the home for routine INR monitoring has demonstrated reliability, safety and effectiveness in the management of infants and children requiring long-term warfarin therapy. However, a comprehensive cost-analysis of using this method of management, compared to attending anticoagulation clinics has not been reported. The aim of this study was to compare the estimated societal costs of attending anticoagulation clinics for routine INR monitoring to using a POC test in the home. This study used a comparative before-and-after design that included 60 infants and children managed via the Haematology department at a tertiary paediatric centre. Each participant was exposed to both modes of management at various times for a period of ≥3 months. A questionnaire, consisting of 25 questions was sent to families to complete and return. Data collected included: the frequency of monitoring, mode of travel to and from clinics, total time consumed, and primary carer's income level. The home monitoring cohort saved a total of 1 hour 19 minutes per INR test compared to attending anticoagulation clinics and had a cost saving to society of $66.83 (AUD) per INR test compared to traditional care; incorporating health sector costs, travel expenses and lost time. The traditional model of care requires a considerable investment of time per test from both child and carer. Home INR monitoring in infants and children provides greater societal economic benefits compared to traditional models. Copyright © 2013 Elsevier Ltd. All rights reserved.
Hyle, Emily P; Jani, Ilesh V; Rosettie, Katherine L; Wood, Robin; Osher, Benjamin; Resch, Stephen; Pei, Pamela P; Maggiore, Paolo; Freedberg, Kenneth A; Peter, Trevor; Parker, Robert A; Walensky, Rochelle P
2017-09-24
To examine the clinical and economic value of point-of-care CD4 (POC-CD4) or viral load monitoring compared with current practices in Mozambique, a country representative of the diverse resource limitations encountered by HIV treatment programs in sub-Saharan Africa. We use the Cost-Effectiveness of Preventing AIDS Complications-International model to examine the clinical impact, cost (2014 US$), and incremental cost-effectiveness ratio [$/year of life saved (YLS)] of ART monitoring strategies in Mozambique. We compare: monitoring for clinical disease progression [clinical ART monitoring strategy (CLIN)] vs. annual POC-CD4 in rural settings without laboratory services and biannual laboratory CD4 (LAB-CD4), biannual POC-CD4, and annual viral load in urban settings with laboratory services. We examine the impact of a range of values in sensitivity analyses, using Mozambique's 2014 per capita gross domestic product ($620) as a benchmark cost-effectiveness threshold. In rural settings, annual POC-CD4 compared to CLIN improves life expectancy by 2.8 years, reduces time on failed ART by 0.6 years, and yields an incremental cost-effectiveness ratio of $480/YLS. In urban settings, biannual POC-CD4 is more expensive and less effective than viral load. Compared to biannual LAB-CD4, viral load improves life expectancy by 0.6 years, reduces time on failed ART by 1.0 year, and is cost-effective ($440/YLS). In rural settings, annual POC-CD4 improves clinical outcomes and is cost-effective compared to CLIN. In urban settings, viral load has the greatest clinical benefit and is cost-effective compared to biannual POC-CD4 or LAB-CD4. Tailoring ART monitoring strategies to specific settings with different available resources can improve clinical outcomes while remaining economically efficient.
Hale, LaDonna S; Wallace, Michelle M; Adams, Courtney R; Kaufman, Michelle L; Snyder, Courtney L
2015-09-01
Selecting resources to support didactic courses is a critical decision, and the advantages and disadvantages must be carefully considered. During clinical rotations, students not only need to possess strong background knowledge but also are expected to be proficient with the same evidence-based POC resources used by clinicians. Students place high value on “real world” learning and therefore may place more value on POC resources that they know practicing clinicians use as compared with medical textbooks. The condensed nature of PA education requires students to develop background knowledge and information literacy skills over a short period. One way to build that knowledge and those skills simultaneously is to use POC resources in lieu of traditional medical textbooks during didactic training. Electronic POC resources offer several advantages over traditional textbooks and should be considered as viable options in PA education.
Mashamba-Thompson, T P; Drain, P K; Sartorius, B
2016-01-01
Introduction Poor healthcare access is a major barrier to receiving antenatal care and a cause of high maternal mortality in South Africa (SA). ‘Point-of-care’ (POC) diagnostics is a powerful emerging healthcare approach to improve healthcare access. This study focuses on evaluating the accessibility and utility of POC diagnostics for maternal health in rural SA primary healthcare (PHC) clinics in order to generate a model framework of implementation of POC diagnostics in rural South African clinics. Method and analyses We will use several research methods, including a systematic review, quasi-experiments, survey, key informant interviews and audits. We will conduct a systematic review and experimental study to determine the impact of POC diagnostics on maternal health. We will perform a cross-sectional case study of 100 randomly selected rural primary healthcare clinics in KwaZulu-Natal to measure the context and patterns of POC diagnostics access and usage by maternal health providers and patients. We will conduct interviews with relevant key stakeholders to determine the reasons for POC deficiencies regarding accessibility and utility of HIV-related POC diagnostics for maternal health. We will also conduct a vertical audit to investigate all the quality aspects of POC diagnostic services including diagnostic accuracy in a select number of clinics. On the basis of information gathered, we will propose a model framework for improved implementation of POC diagnostics in rural South African public healthcare clinics. Statistical (Stata-13) and thematic (NVIVO) data analysis will be used in this study. Ethics and dissemination The study protocol was approved by the Ethics Committee of the University of KwaZulu-Natal (BE 484/14) and the KwaZulu-Natal Department of Health based on the Helsinki Declaration (HRKM 40/15). Findings of this study will be disseminated electronically and in print. They will be presented to conferences related to HIV/AIDS, diagnostics
Duran-Nelson, Alisa; Gladding, Sophia; Beattie, Jim; Nixon, L James
2013-06-01
To determine which resources residents use at the point-of-care (POC) for decision making, the drivers for selection of these resources, and how residents use Google/Google Scholar to answer clinical questions at the POC. In January 2012, 299 residents from three internal medicine residencies were sent an electronic survey regarding resources used for POC decision making. Resource use frequency and factors influencing choice were determined using descriptive statistics. Binary logistic regression analysis was performed to determine relationships between the independent variables. A total of 167 residents (56%) responded; similar numbers responded at each level of training. Residents most frequently reported using UpToDate and Google at the POC at least daily (85% and 63%, respectively), with speed and trust in the quality of information being the primary drivers of selection. Google, used by 68% of residents, was used primarily to locate Web sites and general information about diseases, whereas Google Scholar, used by 30% of residents, tended to be used for treatment and management decisions or locating a journal article. The findings suggest that internal medicine residents use UpToDate most frequently, followed by consultation with faculty and the search engines Google and Google Scholar; speed, trust, and portability are the biggest drivers for resource selection; and time and information overload appear to be the biggest barriers to resources such as Ovid MEDLINE. Residents frequently used Google and may benefit from further training in information management skills.
Point-of-care testing system enabling 30 min detection of influenza genes.
Abe, Tomoteru; Segawa, Yuji; Watanabe, Hidetoshi; Yotoriyama, Tasuku; Kai, Shinichi; Yasuda, Akio; Shimizu, Norio; Tojo, Naoko
2011-03-21
We developed a portable and easy-to-use nucleic acid amplification test (NAT) system for use in point-of-care testing (POCT). The system shows sensitivity that is sufficiently higher than that of the currently available rapid diagnostic kit and is comparable to that of real-time reverse transcription polymerase chain reaction (RT-PCR) for influenza testing. This journal is © The Royal Society of Chemistry 2011
Microfluidic Surface Plasmon Resonance Sensors: From Principles to Point-of-Care Applications
Wang, Da-Shin; Fan, Shih-Kang
2016-01-01
Surface plasmon resonance (SPR) is a label-free, highly-sensitive, and real-time sensing technique. Conventional SPR sensors, which involve a planar thin gold film, have been widely exploited in biosensing; various miniaturized formats have been devised for portability purposes. Another type of SPR sensor which utilizes localized SPR (LSPR), is based on metal nanostructures with surface plasmon modes at the structural interface. The resonance condition is sensitive to the refractive index change of the local medium. The principles of these two types of SPR sensors are reviewed and their integration with microfluidic platforms is described. Further applications of microfluidic SPR sensors to point-of-care (POC) diagnostics are discussed. PMID:27472340
An Audio Jack-Based Electrochemical Impedance Spectroscopy Sensor for Point-of-Care Diagnostics.
Jiang, Haowei; Sun, Alex; Venkatesh, A G; Hall, Drew A
2017-02-01
Portable and easy-to-use point-of-care (POC) diagnostic devices hold high promise for dramatically improving public health and wellness. In this paper, we present a mobile health (mHealth) immunoassay platform based on audio jack embedded devices, such as smartphones and laptops, that uses electrochemical impedance spectroscopy (EIS) to detect binding of target biomolecules. Compared to other biomolecular detection tools, this platform is intended to be used as a plug-and-play peripheral that reuses existing hardware in the mobile device and does not require an external battery, thereby improving upon its convenience and portability. Experimental data using a passive circuit network to mimic an electrochemical cell demonstrate that the device performs comparably to laboratory grade instrumentation with 0.3% and 0.5° magnitude and phase error, respectively, over a 17 Hz to 17 kHz frequency range. The measured power consumption is 2.5 mW with a dynamic range of 60 dB. This platform was verified by monitoring the real-time formation of a NeutrAvidin self-assembled monolayer (SAM) on a gold electrode demonstrating the potential for POC diagnostics.
Tuite, Ashleigh R; Gift, Thomas L; Chesson, Harrell W; Hsu, Katherine; Salomon, Joshua A; Grad, Yonatan H
2017-01-01
Abstract Background Increasing antibiotic resistance limits treatment options for gonorrhea. We examined the impact of a hypothetical point-of-care (POC) test reporting antibiotic susceptibility profiles on slowing resistance spread. Methods A mathematical model describing gonorrhea transmission incorporated resistance emergence probabilities and fitness costs associated with resistance based on characteristics of ciprofloxacin (A), azithromycin (B), and ceftriaxone (C). We evaluated time to 1% and 5% prevalence of resistant strains among all isolates with the following: (1) empiric treatment (B and C), and treatment guided by POC tests determining susceptibility to (2) A only and (3) all 3 antibiotics. Results Continued empiric treatment without POC testing was projected to result in >5% of isolates being resistant to both B and C within 15 years. Use of either POC test in 10% of identified cases delayed this by 5 years. The 3 antibiotic POC test delayed the time to reach 1% prevalence of triply-resistant strains by 6 years, whereas the A-only test resulted in no delay. Results were less sensitive to assumptions about fitness costs and test characteristics with increasing test uptake. Conclusions Rapid diagnostics reporting antibiotic susceptibility may extend the usefulness of existing antibiotics for gonorrhea treatment, but ongoing monitoring of resistance patterns will be critical. PMID:28968710
Point-of-care test identifies diabetic ketoacidosis at triage.
Naunheim, Rosanne; Jang, Timothy J; Banet, Gerald; Richmond, Alec; McGill, Janet
2006-06-01
Diabetic ketoacidosis (DKA) is a common, life-threatening complication of diabetes. The diagnosis of DKA relies on signs and symptoms, plus laboratory findings of blood glucose (BG) of > 250 mg/dL, an anion gap (AG) of > or = 15 mmol/L, and carbon dioxide (CO2) of < or = 18 mmol/L when other causes of acidosis are excluded. To compare the results of a point-of-care test for the ketone beta-hydroxybutyrate (beta-OHB) with standard measures for accuracy in predicting DKA. After providing informed consent, 160 patients who presented with BG of > 250 mg/dL underwent testing for beta-OHB with the Precision Xtra meter (Abbott Laboratories, North Chicago, IL) at triage in a large urban hospital emergency department. The diagnosis of DKA was made by clinicians by using standard clinical criteria without knowledge of the beta-OHB test. A diagnosis of DKA was made in 57 of 160 subjects. The beta-OHB values correlated strongly with AG (r = 0.66, p < 0.001) and with CO2 (r = -0.69, p < 0.001), as well as with glucose (r = 0.31, p < 0.001). Cross-classification of DKA vs. beta-OHB yielded sensitivity of 98% (95% CI = 91% to 100%), specificity of 85% (95% CI = 78% to 91%), with a positive likelihood ratio of 6.7 (95% CI = 4.22 to 10.78), and negative likelihood ratio of 0.021 (95% CI = 0.003 to 0.144) at the manufacturer-suggested beta-OHB level of 1.5. The point-of-care test for beta-OHB was as sensitive as more established indicators of DKA. It is more useful than glucose alone for the diagnosis of DKA and offers immediate diagnosis of patients at triage.
Stoot, Lauren J.; Cairns, Nicholas A.; Cull, Felicia; Taylor, Jessica J.; Jeffrey, Jennifer D.; Morin, Félix; Mandelman, John W.; Clark, Timothy D.; Cooke, Steven J.
2014-01-01
Non-human vertebrate blood is commonly collected and assayed for a variety of applications, including veterinary diagnostics and physiological research. Small, often non-lethal samples enable the assessment and monitoring of the physiological state and health of the individual. Traditionally, studies that rely on blood physiology have focused on captive animals or, in studies conducted in remote settings, have required the preservation and transport of samples for later analysis. In either situation, large, laboratory-bound equipment and traditional assays and analytical protocols are required. The use of point-of-care (POC) devices to measure various secondary blood physiological parameters, such as metabolites, blood gases and ions, has become increasingly popular recently, due to immediate results and their portability, which allows the freedom to study organisms in the wild. Here, we review the current uses of POC devices and their applicability to basic and applied studies on a variety of non-domesticated species. We located 79 individual studies that focused on non-domesticated vertebrates, including validation and application of POC tools. Studies focused on a wide spectrum of taxa, including mammals, birds and herptiles, although the majority of studies focused on fish, and typical variables measured included blood glucose, lactate and pH. We found that calibrations for species-specific blood physiology values are necessary, because ranges can vary within and among taxa and are sometimes outside the measurable range of the devices. In addition, although POC devices are portable and robust, most require durable cases, they are seldom waterproof/water-resistant, and factors such as humidity and temperature can affect the performance of the device. Overall, most studies concluded that POC devices are suitable alternatives to traditional laboratory devices and eliminate the need for transport of samples; however, there is a need for greater emphasis on rigorous
Scenario-Based Assessment of User Needs for Point-of-Care Robots
Lee, Hyeong Suk
2018-01-01
Objectives This study aimed to derive specific user requirements and barriers in a real medical environment to define the essential elements and functions of two types of point-of-care (POC) robot: a telepresence robot as a tool for teleconsultation, and a bedside robot to provide emotional care for patients. Methods An analysis of user requirements was conducted; user needs were gathered and identified, and detailed, realistic scenarios were created. The prototype robots were demonstrated in physical environments for envisioning and evaluation. In all, three nurses and three clinicians participated as evaluators to observe the demonstrations and evaluate the robot systems. The evaluators were given a brief explanation of each scene and the robots' functionality. Four major functions of the teleconsultation robot were defined and tested in the demonstration. In addition, four major functions of the bedside robot were evaluated. Results Among the desired functions for a teleconsultation robot, medical information delivery and communication had high priority. For a bedside robot, patient support, patient monitoring, and healthcare provider support were the desired functions. The evaluators reported that the teleconsultation robot can increase support from and access to specialists and resources. They mentioned that the bedside robot can improve the quality of hospital life. Problems identified in the demonstration were those of space conflict, communication errors, and safety issues. Conclusions Incorporating this technology into healthcare services will enhance communication and teamwork skills across distances and thereby facilitate teamwork. However, repeated tests will be needed to evaluate and ensure improved performance. PMID:29503748
Villalar, J L; Arredondo, M T; Meneu, T; Traver, V; Cabrera, M F; Guillen, S; Del Pozo, F
2002-01-01
Centralized testing demands costly laboratories, which are inefficient and may provide poor services. Recent advances make it feasible to move clinical testing nearer to patients and the requesting physicians, thus reducing the time to treatment. Internet technologies can be used to create a virtual laboratory information system in a distributed health-care environment. This allows clinical testing to be transferred to a cooperative scheme of several point-of-care testing (POCT) nodes. Two pilot virtual laboratories were established, one in Italy (AUSL Modena) and one in Greece (Athens Medical Centre). They were constructed on a three-layer model to allow both technical and clinical verification. Different POCT devices were connected. The pilot sites produced good preliminary results in relation to user acceptance, efficiency, convenience and costs. Decentralized laboratories can be expected to become cost-effective.
Harding-Esch, Emma M; Nori, Achyuta V; Hegazi, Aseel; Pond, Marcus J; Okolo, Olanike; Nardone, Anthony; Lowndes, Catherine M; Hay, Phillip; Sadiq, S Tariq
2017-09-01
To assess clinical service value of STI point-of-care test (POCT) use in a 'sample first' clinical pathway (patients providing samples on arrival at clinic, before clinician consultation). Specific outcomes were: patient acceptability; whether a rapid nucleic acid amplification test (NAAT) for Chlamydia trachomatis/Neisseria gonorrhoeae (CT/NG) could be used as a POCT in practice; feasibility of non-NAAT POCT implementation for Trichomonas vaginalis (TV) and bacterial vaginosis (BV); impact on patient diagnosis and treatment. Service evaluation in a south London sexual health clinic. Symptomatic female and male patients and sexual contacts of CT/NG-positive individuals provided samples for diagnostic testing on clinic arrival, prior to clinical consultation. Tests included routine culture and microscopy; CT/NG (GeneXpert) NAAT; non-NAAT POCTs for TV and BV. All 70 (35 males, 35 females) patients approached participated. The 'sample first' pathway was acceptable, with >90% reporting they were happy to give samples on arrival and receive results in the same visit. Non-NAAT POCT results were available for all patients prior to leaving clinic; rapid CT/NG results were available for only 21.4% (15/70; 5 males, 10 females) of patients prior to leaving clinic. Known negative CT/NG results led to two females avoiding presumptive treatment, and one male receiving treatment directed at possible Mycoplasma genitalium infection causing non-gonococcal urethritis. Non-NAAT POCTs detected more positives than routine microscopy (TV 3 vs 2; BV 24 vs 7), resulting in more patients receiving treatment. A 'sample first' clinical pathway to enable multiple POCT use was acceptable to patients and feasible in a busy sexual health clinic, but rapid CT/NG processing time was too long to enable POCT use. There is need for further development to improve test processing times to enable POC use of rapid NAATs. Published by the BMJ Publishing Group Limited. For permission to use (where not
Point-of-care test for cervical cancer in LMICs.
Mohammed, Sulma I; Ren, Wen; Flowers, Lisa; Rajwa, Bartek; Chibwesha, Carla J; Parham, Groesbeck P; Irudayaraj, Joseph M K
2016-04-05
Cervical cancer screening using Papanicolaou's smear test has been highly effective in reducing death from this disease. However, this test is unaffordable in low- and middle-income countries, and its complexity has limited wide-scale uptake. Alternative tests, such as visual inspection with acetic acid or Lugol's iodine and human papillomavirus DNA, are sub-optimal in terms of specificity and sensitivity, thus sensitive and affordable tests with high specificity for on-site reporting are needed. Using proteomics and bioinformatics, we have identified valosin-containing protein (VCP) as differentially expressed between normal specimens and those with cervical intra-epithelial neoplasia grade 2/3 (CIN2/CIN3+) or worse. VCP-specific immunohistochemical staining (validated by a point-of-care technology) provided sensitive (93%) and specific (88%) identification of CIN2/CIN3+ and may serve as a critical biomarker for cervical-cancer screening. Future efforts will focus on further refinements to enhance analytic sensitivity and specificity of our proposed test, as well as on prototype development.
Storing self-contained gel capillary cassettes for POC medical diagnostics.
Manage, Dammika P; Lauzon, Jana; Zahariadis, George; Pilarski, Linda M
2013-10-21
For effective clinical uptake of the lab on a chip/point of care technology (LOC-POC), in addition to cost advantages LOC-POC devices should offer multiple patient screening panels for related diseases as well as cold-chain transportation and storage abilities. We recently described a device that performs polymerase chain reaction (PCR) to simultaneously screen raw clinical samples from up to 16 patients for multiple infectious agents (Manage et al., Lab Chip, 2013, 13, 2576-2584). This cassette contains glass capillaries with desiccated semi-solid acrylamide gels that include all the reagents except for the sample, with integrated quality control. Here we report the development of protocols to store assembled PCR cassettes at room temperature, 4 °C or -20 °C as well as at +40 °C. We show that our cassettes are stable, with no loss of activity for at least 3 months at RT and at least 7 months at 4 °C and -20 °C. However, the activity of desiccated cassettes degrades when stored for more than 2 weeks at 40 °C, insufficient time for post-manufacture delivery and use of cassette PCR. To address this, we have evaluated two stage storage protocols. PCR cassettes can initially be stored at 4 °C and -20 °C for prolonged periods of time and removed for shorter term storage at RT, retaining activity for at least a month, which would facilitate transport to remote areas for testing. Effective use of cassette PCR in high temperature regions of the world, for experimental purposes defined here as 40 °C, appears to be feasible only after a first stage storage in the cold, followed by no more than 1 week at 40 °C. This should allow sufficient time for delivery by the manufacturer to a central area well served by power and refrigeration, for later ambient temperature transport and use in under-resourced areas that lack refrigeration.
Significance of pregnancy test false negative results due to elevated levels of β-core fragment hCG.
Johnson, Sarah; Eapen, Saji; Smith, Peter; Warren, Graham; Zinaman, Michael
2017-01-01
Very high levels of β-core fragment human chorionic gonadotrophin (βcf-hCG) are reported to potentially cause false negative results in point-of-care (POC)/over-the-counter (OTC) pregnancy tests. To investigate this further, women's daily early morning urine samples, collected prior to conception and during pregnancy, were analysed for intact, free β-, and βcf-hCG. The proportion of βcf-hCG was found to be related to that of hCG produced and in circulation. Therefore, best practice for accuracy testing of POC/OTC pregnancy tests would be to test devices against clinical samples containing high levels of βcf-hCG as well as standards spiked with biologically relevant ratios.
An integrated paper-based sample-to-answer biosensor for nucleic acid testing at the point of care.
Choi, Jane Ru; Hu, Jie; Tang, Ruihua; Gong, Yan; Feng, Shangsheng; Ren, Hui; Wen, Ting; Li, XiuJun; Wan Abas, Wan Abu Bakar; Pingguan-Murphy, Belinda; Xu, Feng
2016-02-07
With advances in point-of-care testing (POCT), lateral flow assays (LFAs) have been explored for nucleic acid detection. However, biological samples generally contain complex compositions and low amounts of target nucleic acids, and currently require laborious off-chip nucleic acid extraction and amplification processes (e.g., tube-based extraction and polymerase chain reaction (PCR)) prior to detection. To the best of our knowledge, even though the integration of DNA extraction and amplification into a paper-based biosensor has been reported, a combination of LFA with the aforementioned steps for simple colorimetric readout has not yet been demonstrated. Here, we demonstrate for the first time an integrated paper-based biosensor incorporating nucleic acid extraction, amplification and visual detection or quantification using a smartphone. A handheld battery-powered heating device was specially developed for nucleic acid amplification in POC settings, which is coupled with this simple assay for rapid target detection. The biosensor can successfully detect Escherichia coli (as a model analyte) in spiked drinking water, milk, blood, and spinach with a detection limit of as low as 10-1000 CFU mL(-1), and Streptococcus pneumonia in clinical blood samples, highlighting its potential use in medical diagnostics, food safety analysis and environmental monitoring. As compared to the lengthy conventional assay, which requires more than 5 hours for the entire sample-to-answer process, it takes about 1 hour for our integrated biosensor. The integrated biosensor holds great potential for detection of various target analytes for wide applications in the near future.
Hegener, Michael A; Li, Hua; Han, Daewoo; Steckl, Andrew J; Pauletti, Giovanni M
2017-09-01
Vitamin K antagonists such as warfarin are the most widely used class of oral anticoagulants. Due to a narrow therapeutic window, patients on warfarin require regular monitoring. Self-testing using point-of-care (POC) diagnostic devices is available, but cost makes this monitoring method beyond reach for many. The main objective of this research was to assess the clinical utility of a low-cost, paper-based lateral flow POC diagnostic device developed for anticoagulation monitoring without the need for a separate electronic reader. Custom-fabricated lateral flow assay (LFA) test strips comprised of a glass fiber sample pad, a nitrocellulose analytical membrane, a cellulose wicking pad, and a plastic backing card were assembled in a plastic cassette. Healthy volunteers and patients on warfarin therapy were recruited for this prospective study. For each participant, a whole blood sample was collected via fingerstick to determine: (1) international normalized ratio (INR) using the CoaguChek® XS coagulometer, (2) hematocrit by centrifugation, and (3) red blood cell (RBC) travel distance on the experimental LFA device after 240 s using digital image analysis. RBC travel distance measured on the LFA device using blood samples obtained from warfarin patients positively correlated with increasing INR value and the LFA device had the capability to statistically distinguish between healthy volunteer INR values and those for patients groups with INR ≥ 2.6. From these data, it is predicted that this low-cost, paper-based LFA device can have clinical utility for identifying anticoagulated patients taking vitamin K antagonists who are outside of the desired therapeutic efficacy window.
Houlbert, C; Annaix, V; Szymanowicz, A; Vassault, A; Guimont, M C; Pernet, P
2012-02-01
In this paper, guidelines are proposed to fulfill the requirements of EN ISO 22870 standard regarding the management of point-of-care testing (POCT) nonconformities. In the first part, the main nonconformities that may affect POCT are given, the means for resolution and the control of adverse events are proposed. In the second part, we propose recommendations in case of unavailability of a point-of-care testing device from the occurring of the adverse event, to the restarting of the device.
Semiquantitative Nucleic Acid Test with Simultaneous Isotachophoretic Extraction and Amplification.
Bender, Andrew T; Borysiak, Mark D; Levenson, Amanda M; Lillis, Lorraine; Boyle, David S; Posner, Jonathan D
2018-06-19
Nucleic acid amplification tests (NAATs) provide high diagnostic accuracy for infectious diseases and quantitative results for monitoring viral infections. The majority of NAATs require complex equipment, cold chain dependent reagents, and skilled technicians to perform the tests. This largely confines NAATs to centralized laboratories and can significantly delay appropriate patient care. Low-cost, point-of-care (POC) NAATs are especially needed in low-resource settings to provide patients with diagnosis and treatment planning in a single visit to improve patient care. In this work, we present a rapid POC NAAT with integrated sample preparation and amplification using electrokinetics and paper substrates. We use simultaneous isotachophoresis (ITP) and recombinase polymerase amplification (RPA) to rapidly extract, amplify, and detect target nucleic acids from serum and whole blood in a paper-based format. We demonstrate simultaneous ITP and RPA can consistently detect 5 copies per reaction in buffer and 10 000 copies per milliliter of human serum with no intermediate user steps. We also show preliminary extraction and amplification of DNA from whole blood samples. Our test is rapid (results in less than 20 min) and made from low-cost materials, indicating its potential for detecting infectious diseases and monitoring viral infections at the POC in low resource settings.
Practical challenges related to point of care testing.
Shaw, Julie L V
2016-04-01
Point of care testing (POCT) refers to laboratory testing that occurs near to the patient, often at the patient bedside. POCT can be advantageous in situations requiring rapid turnaround time of test results for clinical decision making. There are many challenges associated with POCT, mainly related to quality assurance. POCT is performed by clinical staff rather than laboratory trained individuals which can lead to errors resulting from a lack of understanding of the importance of quality control and quality assurance practices. POCT is usually more expensive than testing performed in the central laboratory and requires a significant amount of support from the laboratory to ensure the quality testing and meet accreditation requirements. Here, specific challenges related to POCT compliance with accreditation standards are discussed along with strategies that can be used to overcome these challenges. These areas include: documentation of POCT orders, charting of POCT results as well as training and certification of individuals performing POCT. Factors to consider when implementing connectivity between POCT instruments and the electronic medical record are also discussed in detail and include: uni-directional versus bidirectional communication, linking patient demographic information with POCT software, the importance of positive patient identification and considering where to chart POCT results in the electronic medical record.
Cui, Xingye; Hu, Jie; Choi, Jane Ru; Huang, Yalin; Wang, Xuemin; Lu, Tian Jian; Xu, Feng
2016-09-07
A volumetric meter chip was developed for quantitative point-of-care (POC) analysis of bovine catalase, a bioindicator of bovine mastitis, in milk samples. The meter chip displays multiplexed quantitative results by presenting the distance of ink bar advancement that is detectable by the naked eye. The meter chip comprises a poly(methyl methacrylate) (PMMA) layer, a double-sided adhesive (DSA) layer and a glass slide layer fabricated by the laser-etching method, which is typically simple, rapid (∼3 min per chip), and cost effective (∼$0.2 per chip). Specially designed "U shape" reaction cells are covered by an adhesive tape that serves as an on-off switch, enabling the simple operation of the assay. As a proof of concept, we employed the developed meter chip for the quantification of bovine catalase in raw milk samples to detect catalase concentrations as low as 20 μg/mL. The meter chip has great potential to detect various target analytes for a wide range of POC applications. Copyright © 2016 Elsevier B.V. All rights reserved.
[Point-of-care-testing--the intensive care laboratory].
Müller, M M; Hackl, W; Griesmacher, A
1999-01-01
After successful centralization of laboratory analyses since more than 30 years, advances in biosensors, microprocessors, measurement of undiluted whole blood and miniaturization of laboratory analyzers are leading nowadays more and more to a re-decentralization in the laboratory medicine. Point-of-care-testing (POCT), which is defined as any laboratory test performed outside central or decentralized laboratories, is becoming more and more popular. The theoretical advantages of POCT are faster turn-around-times (TAT), more rapid medical decisions, avoidance of sample identification and sample transport problems and the need of only small specimen volumes. These advantages are frequently mentioned, but are not associated with a clear clinical benefit. The disadvantages of POCT such as incorrect handling and/or maintenance of the analyzers by nontrained clinical staff, inadequate or even absent calibrations and/or quality controls, lack of cost-effectiveness because of an increased number of analyzers and more expensive reagents, insufficient documentation and difficult comparability of the obtained POCT-results with routine laboratory results, are strongly evident. According to the authors' opinion the decision for the establishing of POCT has only to be made in a close co-operation between physicians and laboratorians in order to vouch for necessity and high quality of the analyses. Taking the local situation into consideration (24-h-central laboratory, etc.) the spectrum of parameters measured by means of POCT should be rigorously restricted to the vital functions. Such analytes should be: hemoglobin or hematocrit, activated whole blood clotting time, blood gases, sodium, potassium, ionized calcium, glucose, creatinine, ammonia and lactate.
Engel, Nora; Ganesh, Gayatri; Patil, Mamata; Yellappa, Vijayashree; Pant Pai, Nitika; Vadnais, Caroline; Pai, Madhukar
2015-01-01
Background Successful point-of-care testing, namely ensuring the completion of the test and treat cycle in the same encounter, has immense potential to reduce diagnostic and treatment delays, and impact patient outcomes. However, having rapid tests is not enough, as many barriers may prevent their successful implementation in point-of-care testing programs. Qualitative research on diagnostic practices may help identify such barriers across different points of care in health systems. Methods In this exploratory qualitative study, we conducted 78 semi-structured interviews and 13 focus group discussions in an urban and rural area of Karnataka, India, with healthcare providers (doctors, nurses, specialists, traditional healers, and informal providers), patients, community health workers, test manufacturers, laboratory technicians, program managers and policy-makers. Participants were purposively sampled to represent settings of hospitals, peripheral labs, clinics, communities and homes, in both the public and private sectors. Results In the Indian context, the onus is on the patient to ensure successful point-of-care testing across homes, clinics, labs and hospitals, amidst uncoordinated providers with divergent and often competing practices, in settings lacking material, money and human resources. We identified three overarching themes affecting point-of-care testing: the main theme is ‘relationships’ among providers and between providers and patients, influenced by the cross-cutting theme of ‘infrastructure’. Challenges with both result in ‘modified practices’ often favouring empirical (symptomatic) treatment over treatment guided by testing. Conclusions Even if tests can be conducted on the spot and infrastructure challenges have been resolved, relationships among providers and between patients and providers are crucial for successful point-of-care testing. Furthermore, these barriers do not act in isolation, but are interlinked and need to be examined
Burgess, Lois; Sargent, Jason
2007-01-01
From a clinical perspective, the use of mobile technologies, such as Personal Digital Assistants (PDAs) within hospital environments is not new. A paradigm shift however is underway towards the acceptance and utility of these systems within mobile-based healthcare environments. Introducing new technologies and associated work practices has intrinsic risks which must be addressed. This paper contends that intervening to address user concerns as they arise throughout the system development lifecycle will lead to greater levels of user acceptance, while ultimately enhancing the deliverability of a system that provides a best fit with end user needs. It is envisaged this research will lead to the development of a formalised user acceptance framework based on an agile approach to user acceptance measurement. The results of an ongoing study of user perceptions towards a mandated electronic point-of-care information system in the Northern Illawarra Ambulatory Care Team (TACT) are presented.
Van den Bruel, Ann; Jones, Caroline; Thompson, Matthew; Mant, David
2016-04-01
Point-of-care C-reactive protein (CRP) testing of adults with acute respiratory infection in primary care reduces antibiotic prescribing by 22%. The acceptability and impact of CRP testing in children is unknown To determine the acceptability and impact of CRP testing in acutely ill children. Mixed methods study comprising an observational cohort with a nested randomised controlled trial and embedded qualitative study. Children presenting with an acute illness to general practice out-of-hours services; children with a temperature ≥38°C were randomised in the nested trial; parents and clinical staff were invited to the qualitative study. Informed consent rates; parental and staff views on testing. Consent to involvement in the study was obtained for 200/297 children (67.3%, 95% CI 61.7% to 72.6%); the finger-prick test might have been a contributory factor for 63 of the 97 children declining participation but it was cited as a definite factor in only 10 cases. None of the parents or staff raised concerns about the acceptability of testing, describing the pain caused as minor and transient. General practitioner views on the utility of the CRP test were inconsistent. CRP point-of-care testing in children is feasible in primary care and is likely to be acceptable. However, it will not reduce antibiotic prescribing and hospital referrals until general practitioners accept its diagnostic value in children. ISRCTN 69736109. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/
Milhorn, Denise; Korpi-Steiner, Nichole
2015-02-01
It is unclear if the point-of-care (POC) Clinitest hCG device is subject to high-dose hook interference from physiological concentrations of intact human chorionic gonadotropin (hCG), β-core fragment of hCG (hCGβcf), and hCG free β-subunit (hCGβ) found in urine during pregnancy. We used a simulation model to address this question and related our findings to our institution's pregnant population in order to assess risk for potential false-negative hCG results. The expected distribution of days relative to ovulation during routine POC hCG testing was estimated from 182 patients. Clinitest-Clinitek Status hCG device susceptibility to high-dose hook interference from hCG variants and potential risk of false-negative results as it relates to this population were evaluated by testing increasing concentrations of hCG, hCGβcf, hCGβ as well as urine simulating physiological hCG, hCGβcf and hCGβ concentrations expected during early pregnancy (≤44 days post-ovulation). The Clinitest-Clinitek Status hCG device exhibited high-dose hook interference from hCGβcf alone, but not from hCG, hCGβ, or simulated physiological urinary concentrations of combined hCG, hCGβcf and hCGβ expected during early pregnancy. The majority of our patient population had urinary hCG testing conducted during early pregnancy. The Clinitest-Clinitek Status hCG device is unlikely to exhibit false-negative urinary hCG results due to high-dose hook interference for women in early healthy pregnancy, although additional studies are necessary to determine potential risk in other patient populations. Visual interpretation of POC urinary hCG device results is an important failure mode to consider in risk analyses for erroneous urinary hCG device results. Published by Elsevier Inc.
Ashley, Laura; Jones, Helen; Forman, David; Newsham, Alex; Brown, Julia; Downing, Amy; Velikova, Galina; Wright, Penny
2011-10-26
Cancer survivors can face significant physical and psychosocial challenges; there is a need to identify and predict which survivors experience what sorts of difficulties. As highlighted in the UK National Cancer Survivorship Initiative, routine post-diagnostic collection of patient reported outcome measures (PROMs) is required; to be most informative, PROMs must be linked and analysed with patients' diagnostic and treatment information. We have designed and built a potentially cost-efficient UK-scalable electronic system for collecting PROMs via the internet, at regular post-diagnostic time-points, for linking these data with patients' clinical data in cancer registries, and for electronically managing the associated patient monitoring and communications; the electronic Patient-reported Outcomes from Cancer Survivors (ePOCS) system. This study aims to test the feasibility of the ePOCS system, by running it for 2 years in two Yorkshire NHS Trusts, and using the Northern and Yorkshire Cancer Registry and Information Service. Non-metastatic breast, colorectal and prostate cancer patients (largest survivor groups), within 6 months post-diagnosis, will be recruited from hospitals in the Yorkshire Cancer Network. Participants will be asked to complete PROMS, assessing a range of health-related quality-of-life outcomes, at three time-points up to 15 months post-diagnosis, and subsequently to provide opinion on the ePOCS system via a feedback questionnaire. Feasibility will be examined primarily in terms of patient recruitment and retention rates, the representativeness of participating patients, the quantity and quality of collected PROMs data, patients' feedback, the success and reliability of the underpinning informatics, and the system running costs. If sufficient data are generated during system testing, these will be analysed to assess the health-related quality-of-life outcomes reported by patients, and to explore if and how they relate to disease, treatment and
Haenssgen, Marco J; Charoenboon, Nutcha; Althaus, Thomas; Greer, Rachel C; Intralawan, Daranee; Lubell, Yoel
2018-04-01
New and affordable point-of-care testing (POCT) solutions are hoped to guide antibiotic prescription and to help limit antimicrobial resistance (AMR)-especially in low- and middle-income countries where resource constraints often prevent extensive diagnostic testing. Anthropological and sociological research has illuminated the role and impact of rapid point-of-care malaria testing. This paper expands our knowledge about the social implications of non-malarial POCT, using the case study of a C-reactive-protein point-of-care testing (CRP POCT) clinical trial with febrile patients at primary-care-level health centres in Chiang Rai province, northern Thailand. We investigate the social role of CRP POCT through its interactions with (a) the healthcare workers who use it, (b) the patients whose routine care is affected by the test, and (c) the existing patient-health system linkages that might resonate or interfere with CRP POCT. We conduct a thematic analysis of data from 58 purposively sampled pre- and post-intervention patients and healthcare workers in August 2016 and May 2017. We find widespread positive attitudes towards the test among patients and healthcare workers. Patients' views are influenced by an understanding of CRP POCT as a comprehensive blood test that provides specific diagnosis and that corresponds to notions of good care. Healthcare workers use the test to support their negotiations with patients but also to legitimise ethical decisions in an increasingly restrictive antibiotic policy environment. We hypothesise that CRP POCT could entail greater patient adherence to recommended antibiotic treatment, but it could also encourage riskier health behaviour and entail potentially adverse equity implications for patients across generations and socioeconomic strata. Our empirical findings inform the clinical literature on increasingly propagated point-of-care biomarker tests to guide antibiotic prescriptions, and we contribute to the anthropological and
Neves, R C; Stokol, T; Bach, K D; McArt, J A A
2018-02-01
The objective of this study was to assess an optimized ion-selective electrode Ca-module prototype as a potential cow-side device for ionized Ca (iCa) measurements in bovine blood. A linearity experiment showed no deviation from linearity over a range of iCa concentrations compared with a commercial point-of-care (POC) device commonly used in the field (POC VS ; VetScan i-STAT, Abaxis North America, Union City, CA) and a laboratory gold standard benchtop blood-gas analyzer [reference analyzer (RA); ABL-800 FLEX, Radiometer Medical, Copenhagen, Denmark]. Coefficient of variation on 3 samples with high, within-range, and low iCa concentrations ranged from 1.0 to 3.9% for the prototype. A follow-up validation experiment was performed, in which our objectives were to (1) assess the performance of the prototype cow-side against the POC VS (farm gold-standard) using fresh non-anticoagulated whole-blood samples; (2) assess the performance of the prototype and the POC VS against the RA in a diagnostic laboratory using blood collected in a heparin-balanced syringe; and (3) assess the agreement of the prototype and POC VS on-farm (fresh non-anticoagulated whole blood) against the RA on heparin-balanced blood. Finally, sensitivity and specificity of the results obtained by the prototype and the POC VS cow-side compared with the results obtained by the laboratory RA using 3 different iCa cut points for classification of subclinical hypocalcemia were calculated. A total of 101 periparturient Holstein cows from 3 dairy farms in New York State were used for the second experiment. Ionized Ca results from the prototype cow-side were, on average, 0.06 mmol/L higher than the POC VS . With heparin-balanced samples under laboratory conditions, the prototype and POC VS measured an average 0.04 mmol/L higher and lower, respectively, compared with the RA. Results from the prototype and POC VS cow-side were 0.01 mmol/L higher and 0.05 mmol/L lower, respectively, compared with results from
The Matrix Metalloproteinase 9 Point-of-Care Test in Dry Eye.
Lanza, Nicole L; Valenzuela, Felipe; Perez, Victor L; Galor, Anat
2016-04-01
Dry eye is a common, multifactorial disease currently diagnosed by a combination of symptoms and signs. However, the subjective symptoms of dry eye poorly correlate to the current gold standard for diagnostic tests, reflecting the need to develop better objective tests for the diagnosis of dry eye. This review considers the role of ocular surface matrix metalloproteinase 9 (MMP-9) in dry eye and the implications of a novel point-of-care test that measures MMP-9 levels, InflammaDry (RPS, Sarasota, FL) on choosing appropriate therapeutic treatments. Published by Elsevier Inc.
Kaynar, Ozgur; Karapinar, Tolga; Hayirli, Armagan; Baydar, Ersoy
2015-12-01
Data on accuracy and precision of the Lactate Scout point-of-care (POC) analyzer in ovine medicine are lacking. The purpose of the study was to assess the reliability of the Lactate Scout in sheep. Fifty-seven sheep at varying ages with various diseases were included. Blood lactate concentration in samples collected from the jugular vein was measured immediately on the Lactate Scout. Plasma L-lactate concentration was measured by the Cobas autoanalyzer as the reference method. Data were subjected to Student's t-test, Passing-Bablok regression, and Bland-Altman plot analyses for comparison and assessment of accuracy, precision, and reliability. Plasma l-lactate concentration was consistently lower than blood L-lactate concentration (3.06 ± 0.24 vs 3.3 ± 0.3 mmol/L, P < .0001). There was a positive correlation between plasma and blood L-lactate concentrations (r = .98, P < .0001). The Lactate Scout had 99% accuracy and 98% precision with the reference method. Blood (Y) and plasma (X) L-lactate concentrations were fitted to Y = 0.28 + 1.00 · X, with a residual standard deviation of 0.31 and a negligible deviation from the identity line (P = .93). The bias was fitted to Y = 0.10 + 0.05 · X, with Sy.x of 0.44 (P < .07). The Lactate Scout has high accuracy and precision, with a negligible bias. It is a reliable POC analyzer to assess L-lactate concentration in ovine medicine. © 2015 American Society for Veterinary Clinical Pathology.
Warner, Matthew A; Welsby, Ian J; Norris, Phillip J; Silliman, Christopher C; Armour, Sarah; Wittwer, Erica D; Santrach, Paula J; Meade, Laurie A; Liedl, Lavonne M; Nieuwenkamp, Chelsea M; Douthit, Brian; van Buskirk, Camille M; Schulte, Phillip J; Kor, Daryl J
2017-01-01
Introduction The transfusion-related respiratory complications, transfusion-related acute lung injury (TRALI) and transfusion-associated circulatory overload (TACO), are leading causes of transfusion-related morbidity and mortality. At present, there are no effective preventive strategies with red blood cell (RBC) transfusion. Although mechanisms remain incompletely defined, soluble biological response modifiers (BRMs) within the RBC storage solution may play an important role. Point-of-care (POC) washing of allogeneic RBCs may remove these BRMs, thereby mitigating their impact on post-transfusion respiratory complications. Methods and analysis This is a multicenter randomised clinical trial of standard allogeneic versus washed allogeneic RBC transfusion for adult patients undergoing cardiac surgery testing the hypothesis that POC RBC washing is feasible, safe, and efficacious and will reduce recipient immune and physiologic responses associated with transfusion-related respiratory complications. Relevant clinical outcomes will also be assessed. This investigation will enrol 170 patients at two hospitals in the USA. Simon’s two-stage design will be used to assess the feasibility of POC RBC washing. The primary safety outcomes will be assessed using Wilcoxon Rank-Sum tests for continuous variables and Pearson chi-square test for categorical variables. Standard mixed modelling practices will be employed to test for changes in biomarkers of lung injury following transfusion. Linear regression will assess relationships between randomised group and post-transfusion physiologic measures. Ethics and dissemination Safety oversight will be conducted under the direction of an independent Data and Safety Monitoring Board (DSMB). Approval of the protocol was obtained by the DSMB as well as the institutional review boards at each institution prior to enrolling the first study participant. This study aims to provide important information regarding the feasibility of POC
Martínez-López, J. Israel; Mojica, Mauricio; Rodríguez, Ciro A.; Siller, Héctor R.
2016-01-01
Despite the copious amount of research on the design and operation of micromixers, there are few works regarding manufacture technology aimed at implementation beyond academic environments. This work evaluates the viability of xurography as a rapid fabrication tool for the development of ultra-low cost microfluidic technology for extreme Point-of-Care (POC) micromixing devices. By eschewing photolithographic processes and the bulkiness of pumping and enclosure systems for rapid fabrication and passively driven operation, xurography is introduced as a manufacturing alternative for asymmetric split and recombine (ASAR) micromixers. A T-micromixer design was used as a reference to assess the effects of different cutting conditions and materials on the geometric features of the resulting microdevices. Inspection by stereographic and confocal microscopy showed that it is possible to manufacture devices with less than 8% absolute dimensional error. Implementation of the manufacturing methodology in modified circular shape- based SAR microdevices (balanced and unbalanced configurations) showed that, despite the precision limitations of the xurographic process, it is possible to implement this methodology to produce functional micromixing devices. Mixing efficiency was evaluated numerically and experimentally at the outlet of the microdevices with performances up to 40%. Overall, the assessment encourages further research of xurography for the development of POC micromixers. PMID:27196904
Martínez-López, J Israel; Mojica, Mauricio; Rodríguez, Ciro A; Siller, Héctor R
2016-05-16
Despite the copious amount of research on the design and operation of micromixers, there are few works regarding manufacture technology aimed at implementation beyond academic environments. This work evaluates the viability of xurography as a rapid fabrication tool for the development of ultra-low cost microfluidic technology for extreme Point-of-Care (POC) micromixing devices. By eschewing photolithographic processes and the bulkiness of pumping and enclosure systems for rapid fabrication and passively driven operation, xurography is introduced as a manufacturing alternative for asymmetric split and recombine (ASAR) micromixers. A T-micromixer design was used as a reference to assess the effects of different cutting conditions and materials on the geometric features of the resulting microdevices. Inspection by stereographic and confocal microscopy showed that it is possible to manufacture devices with less than 8% absolute dimensional error. Implementation of the manufacturing methodology in modified circular shape- based SAR microdevices (balanced and unbalanced configurations) showed that, despite the precision limitations of the xurographic process, it is possible to implement this methodology to produce functional micromixing devices. Mixing efficiency was evaluated numerically and experimentally at the outlet of the microdevices with performances up to 40%. Overall, the assessment encourages further research of xurography for the development of POC micromixers.
Bereznicki, Luke R E; Jackson, Shane L; Kromdijk, Wiete; Gee, Peter; Fitzmaurice, Kimbra; Bereznicki, Bonnie J; Peterson, Gregory M
2014-02-01
In aged-care facilities (ACFs) monitoring of warfarin can be logistically challenging and International Normalised Ratio (INR control) is often suboptimal. We aimed to determine whether an integrated information and communications technology system and the use of point-of-care (POC) monitors by nursing staff could improve the INR control of aged-care facility residents who take warfarin. Nursing staff identified residents who were prescribed warfarin in participating ACFs. A computer program (MedePOC) was developed to store and transmit INR results from the ACFs to general practitioners (GPs) for dosage adjustment. Nursing staff received training in the use of the CoaguChek XS point-of-care INR monitor and the MedePOC software. Following a run-in phase, eligible patients were monitored weekly for up to 12 weeks. The primary outcome was the change in the time in therapeutic range (TTR) in the intervention phase compared to the TTR in the 12 months preceding the study. All GPs, nursing staff and patients were surveyed for their experiences and opinions of the project. Twenty-four patients and 19 GPs completed the trial across six ACFs. The mean TTR for all patients improved non-significantly from 58.9 to 60.6% (P=0.79) and the proportion of INR tests in range improved non-significantly from 57.1 to 64.1% (P=0.21). The mean TTR improved in 14 patients (58%) and in these patients the mean absolute improvement in TTR was 23.1%. A post hoc analysis of the INR data using modified therapeutic INR ranges to reflect the dosage adjustment practices of GPs suggested that the intervention did lead to improved INR control. The MedePOC program and POC monitoring was well received by nursing staff. Weekly POC INR monitoring conducted in ACFs and electronic communication of the results and warfarin doses resulted in non-significant improvements in INR control in a small cohort of elderly residents. Further research involving modification to the communication strategy and a longer
Selfish mothers? An empirical test of parent-offspring conflict over extended parental care.
Paul, Manabi; Sen Majumder, Sreejani; Bhadra, Anindita
2014-03-01
Parent-offspring conflict (POC) theory is an interesting conceptual framework for understanding the dynamics of parental care. However, this theory is not easy to test empirically, as exact measures of parental investment in an experimental set-up are difficult to obtain. We have used free-ranging dogs Canis familiaris in India, to study POC in the context of extended parental care. We observed females and their pups in their natural habitat for the mother's tendency to share food given by humans with her pups in the weaning and post-weaning stages. Since these dogs are scavengers, and depend largely on human provided food for their sustenance, voluntary sharing of food by the mother with her pups is a good surrogate for extended parental care. Our behavioural observations convincingly demonstrate an increase of conflict and decrease of cooperation by the mother with her offspring over given food within a span of 4-6 weeks. We also demonstrate that the competition among the pups in a litter scales with litter size, an indicator of sib-sib competition. Copyright © 2013 Elsevier B.V. All rights reserved.
Tsakalakis, Michail; Bourbakis, Nicolaos G
2014-01-01
Continuous, real-time remote monitoring through medical point--of--care (POC) systems appears to draw the interest of the scientific community for healthcare monitoring and diagnostic applications the last decades. Towards this direction a significant merit has been due to the advancements in several scientific fields. Portable, wearable and implantable apparatus may contribute to the betterment of today's healthcare system which suffers from fundamental hindrances. The number and heterogeneity of such devices and systems regarding both software and hardware components, i.e sensors, antennas, acquisition circuits, as well as the medical applications that are designed for, is impressive. Objective of the current study is to present the major technological advancements that are considered to be the driving forces in the design of such systems, to briefly state the new aspects they can deliver in healthcare and finally, the identification, categorization and a first level evaluation of them.
2016-01-01
It is important to consider the role of diagnostics and the critical need for quality diagnostics services in resource-limited settings. Accurate diagnostic tests play a key role in patient management and the prevention and control of most infectious diseases. As countries plan for implementation of HIV early infant diagnosis and viral load point-of-care testing, the London School of Hygiene & Tropical Medicine has worked with countries and partners with an interest in external quality assurance to support quality point-of-care testing on the continent. Through a series of collaborative consultations and workshops, the London School of Hygiene & Tropical Medicine has gathered lessons learned, tools, and resources and developed quality assurance models that will support point-of-care testing. The London School of Hygiene & Tropical Medicine is committed to the continued advancement of laboratory diagnostics in Africa and quality laboratory services and point-of-care testing. PMID:28879132
Chang, Wei; Chamie, Gabriel; Mwai, Daniel; Clark, Tamara D; Thirumurthy, Harsha; Charlebois, Edwin D; Petersen, Maya; Kabami, Jane; Ssemmondo, Emmanuel; Kadede, Kevin; Kwarisiima, Dalsone; Sang, Norton; Bukusi, Elizabeth A; Cohen, Craig R; Kamya, Moses; Havlir, Diane V; Kahn, James G
2016-11-01
In 2013-2014, we achieved 89% adult HIV testing coverage using a hybrid testing approach in 32 communities in Uganda and Kenya (SEARCH: NCT01864603). To inform scalability, we sought to determine: (1) overall cost and efficiency of this approach; and (2) costs associated with point-of-care (POC) CD4 testing, multidisease services, and community mobilization. We applied microcosting methods to estimate costs of population-wide HIV testing in 12 SEARCH trial communities. Main intervention components of the hybrid approach are census, multidisease community health campaigns (CHC), and home-based testing for CHC nonattendees. POC CD4 tests were provided for all HIV-infected participants. Data were extracted from expenditure records, activity registers, staff interviews, and time and motion logs. The mean cost per adult tested for HIV was $20.5 (range: $17.1-$32.1) (2014 US$), including a POC CD4 test at $16 per HIV+ person identified. Cost per adult tested for HIV was $13.8 at CHC vs. $31.7 by home-based testing. The cost per HIV+ adult identified was $231 ($87-$1245), with variability due mainly to HIV prevalence among persons tested (ie, HIV positivity rate). The marginal costs of multidisease testing at CHCs were $1.16/person for hypertension and diabetes, and $0.90 for malaria. Community mobilization constituted 15.3% of total costs. The hybrid testing approach achieved very high HIV testing coverage, with POC CD4, at costs similar to previously reported mobile, home-based, or venue-based HIV testing approaches in sub-Saharan Africa. By leveraging HIV infrastructure, multidisease services were offered at low marginal costs.
Basal body stability and ciliogenesis requires the conserved component Poc1
Osborn, Daniel P.S.; Giddings, Thomas H.; Beales, Philip L.; Winey, Mark
2009-01-01
Centrioles are the foundation for centrosome and cilia formation. The biogenesis of centrioles is initiated by an assembly mechanism that first synthesizes the ninefold symmetrical cartwheel and subsequently leads to a stable cylindrical microtubule scaffold that is capable of withstanding microtubule-based forces generated by centrosomes and cilia. We report that the conserved WD40 repeat domain–containing cartwheel protein Poc1 is required for the structural maintenance of centrioles in Tetrahymena thermophila. Furthermore, human Poc1B is required for primary ciliogenesis, and in zebrafish, DrPoc1B knockdown causes ciliary defects and morphological phenotypes consistent with human ciliopathies. T. thermophila Poc1 exhibits a protein incorporation profile commonly associated with structural centriole components in which the majority of Poc1 is stably incorporated during new centriole assembly. A second dynamic population assembles throughout the cell cycle. Our experiments identify novel roles for Poc1 in centriole stability and ciliogenesis. PMID:20008567
Stahl, James E; McGowan, Heather; DiResta, Ellen; Gaydos, Charlotte A.; Klapperich, Catherine; Parrish, John; Korte, Brenda
2015-01-01
The first part of this manuscript is an introduction to systems engineering and how it may be applied to health care and point of care testing (POCT). Systems engineering is an interdisciplinary field that seeks to better understand and manage changes in complex systems and projects as whole. Systems are sets of interconnected elements which interact with each other, are dynamic, change over time and are subject to complex behaviors. The second part of this paper reports on the results of the National Institute of Biomedical Imaging and Bioengineering (NIBIB) workshop exploring the future of point of care testing and technologies and the recognition that these new technologies do not exist in isolation. That they exist within ecosystems of other technologies and systems; and these systems influence their likelihood of success or failure and their effectiveness. In this workshop, a diverse group of individuals from around the country, from disciplines ranging from clinical care, engineering, regulatory affairs and many others to members of the three major National Institutes of Health (NIH) funded efforts in the areas the Centers for POCT for sexually transmitted disease, POCT for the future of Cancer Care, POCT primary care research network, gathered together for a modified deep dive workshop exploring the current state of the art, mapping probable future directions and developing longer term goals. The invitees were broken up into 4 thematic groups: Home, Outpatient, Public/shared space and Rural/global. Each group proceeded to explore the problem and solution space for point of care tests and technology within their theme. While each thematic area had specific challenges, many commonalities also emerged. This effort thus helped create a conceptual framework for POCT as well as identifying many of the challenges for POCT going forward. Four main dimensions were identified as defining the functional space for both point of care testing and treatment, these are
Stahl, James E; McGowan, Heather; DiResta, Ellen; Gaydos, Charlotte A; Klapperich, Catherine; Parrish, John; Korte, Brenda
2015-03-01
The first part of this manuscript is an introduction to systems engineering and how it may be applied to health care and point of care testing (POCT). Systems engineering is an interdisciplinary field that seeks to better understand and manage changes in complex systems and projects as whole. Systems are sets of interconnected elements which interact with each other, are dynamic, change over time and are subject to complex behaviors. The second part of this paper reports on the results of the National Institute of Biomedical Imaging and Bioengineering (NIBIB) workshop exploring the future of point of care testing and technologies and the recognition that these new technologies do not exist in isolation. That they exist within ecosystems of other technologies and systems; and these systems influence their likelihood of success or failure and their effectiveness. In this workshop, a diverse group of individuals from around the country, from disciplines ranging from clinical care, engineering, regulatory affairs and many others to members of the three major National Institutes of Health (NIH) funded efforts in the areas the Centers for POCT for sexually transmitted disease, POCT for the future of Cancer Care, POCT primary care research network, gathered together for a modified deep dive workshop exploring the current state of the art, mapping probable future directions and developing longer term goals. The invitees were broken up into 4 thematic groups: Home, Outpatient, Public/shared space and Rural/global. Each group proceeded to explore the problem and solution space for point of care tests and technology within their theme. While each thematic area had specific challenges, many commonalities also emerged. This effort thus helped create a conceptual framework for POCT as well as identifying many of the challenges for POCT going forward. Four main dimensions were identified as defining the functional space for both point of care testing and treatment, these are
Emerging Technologies for Monitoring Drug-Resistant Tuberculosis at the Point-of-Care
Mani, Vigneshwaran; Wang, ShuQi; Inci, Fatih; De Libero, Gennaro; Singhal, Amit; Demirci, Utkan
2014-01-01
Infectious diseases are the leading cause of death worldwide. Among them, tuberculosis (TB) remains a major threat to public health, exacerbated by the emergence of multiple drug-resistant (MDR) and extensively drug-resistant (XDR) Mycobacterium tuberculosis (Mtb). MDR-Mtb strains are resistant to first-line anti-TB drugs such as isoniazid and rifampicin; whereas XDR-Mtb strains are resistant to additional drugs including at least to any fluoroquinolone and at least one of the second-line anti-TB injectable drugs such as kanamycin, capreomycin, or amikacin. Clinically, these strains have significantly impacted the management of TB in high-incidence developing countries, where systemic surveillance of TB drug resistance is lacking. For effective management of TB on-site, early detection of drug resistance is critical to initiate treatment, to reduce mortality, and to thwart drug-resistant TB transmission. In this review, we discuss the diagnostic challenges to detect drug-resistant TB at the point-of-care (POC). Moreover, we present the latest advances in nano/microscale technologies that can potentially detect TB drug resistance to improve on-site patient care. PMID:24882226
Point-of-Care Testing for Anemia, Diabetes, and Hypertension: A Pharmacy-Based Model in Lima, Peru.
Saldarriaga, Enrique M; Vodicka, Elisabeth; La Rosa, Sayda; Valderrama, Maria; Garcia, Patricia J
Prevention and control of chronic diseases is a high priority for many low- and middle-income countries. This study evaluated the feasibility and acceptability of training pharmacy workers to provide point-of-care testing for 3 chronic diseases-hypertension, diabetes, and anemia-to improve disease detection and awareness through private pharmacies. We developed a multiphase training curriculum for pharmacists and pharmacy technicians to build capacity for identification of risk factors, patient education, point-of-care testing, and referral for abnormal results. We conducted a pre-post evaluation with participants and evaluated results using Student t test for proportions. We conducted point-of-care testing with pharmacy clients and evaluated acceptability by patient characteristics (age, gender, and type of patient) using multiple logistic regression. In total, 72 pharmacy workers (66%) completed the full training curriculum. Pretest scores indicated that pharmacists had more knowledge and skills in chronic disease risk factors, patient education, and testing than pharmacy technicians. All participants improved their knowledge and skills after the training, and post-test scores indicated that pharmacy technicians achieved the same level of competency as pharmacists (P < .01). Additionally, 698 clients received at least 1 test during the study; 53% completed the acceptability survey. Nearly 100% thought the pharmacy could provide faster results, faster and better attention, and better access to basic screening for hypertension, diabetes, and anemia than a traditional health center. Fast service was very important: 41% ranked faster results and 30% ranked faster attention as the most important factor for receiving diagnostic testing in the pharmacy. We found that it is both feasible for pharmacies and acceptable to clients to train pharmacy workers to provide point-of-care testing for anemia, diabetes, and hypertension. This innovative approach holds potential to
Chang, Wei; Chamie, Gabriel; Mwai, Daniel; Clark, Tamara D.; Thirumurthy, Harsha; Charlebois, Edwin D.; Petersen, Maya; Kabami, Jane; Ssemmondo, Emmanuel; Kadede, Kevin; Kwarisiima, Dalsone; Sang, Norton; Bukusi, Elizabeth A.; Cohen, Craig R.; Kamya, Moses; Havlir, Diane V.; Kahn, James G.
2016-01-01
Background In 2013-14, we achieved 89% adult HIV testing coverage using a hybrid testing approach in 32 communities in Uganda and Kenya (SEARCH: NCT01864603). To inform scalability, we sought to determine: 1) overall cost and efficiency of this approach; and 2) costs associated with point-of-care (POC) CD4 testing, multi-disease services, and community mobilization. Methods We applied micro-costing methods to estimate costs of population-wide HIV testing in 12 SEARCH Trial communities. Main intervention components of the hybrid approach are census, multi-disease community health campaigns (CHC), and home-based testing (HBT) for CHC non-attendees. POC CD4 tests were provided for all HIV-infected participants. Data were extracted from expenditure records, activity registers, staff interviews, and time and motion logs. Results The mean cost per adult tested for HIV was $20.5 (range: $17.1 - $32.1) [2014 US$], including a POC CD4 test at $16 per HIV+ person identified. Cost per adult tested for HIV was $13.8 at CHC vs. $31.7 via HBT. The cost per HIV+ adult identified was $231 ($87 - $1,245), with variability due mainly to HIV prevalence among persons tested (i.e., HIV positivity rate). The marginal costs of multi-disease testing at CHCs were $1.16/person for hypertension and diabetes, and $0.90 for malaria. Community mobilization constituted 15.3% of total costs. Conclusions The hybrid testing approach achieved very high HIV testing coverage, with POC CD4, at costs similar to previously reported mobile, home-based, or venue-based HIV testing approaches in sub-Saharan Africa. By leveraging HIV infrastructure, multi-disease services were offered at low marginal costs. PMID:27741031
Point-of-Care Viral Load Testing for Sub-Saharan Africa: Informing a Target Product Profile.
Phillips, Andrew N; Cambiano, Valentina; Nakagawa, Fumiyo; Ford, Deborah; Apollo, Tsitsi; Murungu, Joseph; Rousseau, Christine; Garnett, Geoff; Ehrenkranz, Peter; Bansi-Matharu, Loveleen; Vojnov, Lara; Katz, Zachary; Peeling, Rosanna; Revill, Paul
2016-09-01
Point-of-care viral load tests are being developed to monitor patients on antiretroviral therapy (ART) in sub-Saharan Africa. Test design involves trade-offs between test attributes, including accuracy, complexity, robustness, and cost. We used a model of the human immunodeficiency virus epidemic and ART program in Zimbabwe and found that the attributes of a viral load testing approach that are most influential for cost effectiveness are avoidance of a high proportion of failed tests or results not received, use of an approach that best facilitates retention on ART, and the ability to facilitate greater use of differentiated care, including through expanding coverage of testing availability.
Point-of-Care Viral Load Testing for Sub-Saharan Africa: Informing a Target Product Profile
Phillips, Andrew N.; Cambiano, Valentina; Nakagawa, Fumiyo; Ford, Deborah; Apollo, Tsitsi; Murungu, Joseph; Rousseau, Christine; Garnett, Geoff; Ehrenkranz, Peter; Bansi-Matharu, Loveleen; Vojnov, Lara; Katz, Zachary; Peeling, Rosanna; Revill, Paul
2016-01-01
Point-of-care viral load tests are being developed to monitor patients on antiretroviral therapy (ART) in sub-Saharan Africa. Test design involves trade-offs between test attributes, including accuracy, complexity, robustness, and cost. We used a model of the human immunodeficiency virus epidemic and ART program in Zimbabwe and found that the attributes of a viral load testing approach that are most influential for cost effectiveness are avoidance of a high proportion of failed tests or results not received, use of an approach that best facilitates retention on ART, and the ability to facilitate greater use of differentiated care, including through expanding coverage of testing availability. PMID:27704016
A Novel Field Deployable Point-of-Care Diagnostic Test for Cutaneous Leishmaniasis
2015-10-01
include localized cutaneous leishmaniasis (LCL), and destructive nasal and oropharyngeal lesions of mucosal leishmaniasis (ML). LCL in the New World...the high costs, personnel training and need of sophisticated equipment. Therefore, novel methods to detect leishmaniasis at the POC are urgently needed...To date, there is no field-standardized molecular method based on DNA amplification coupled with Lateral Flow reading to detect leishmaniasis
Scott, Lesley; Gous, Natasha; Carmona, Sergio; Stevens, Wendy
2015-05-01
Point-of-care (POC) HIV viral load (VL) testing offers the potential to reduce turnaround times for antiretroviral therapy monitoring, offer near-patient acute HIV diagnosis in adults, extend existing centralized VL services, screen women in labor, and prompt pediatrics to early treatment. The Liat HIV Quant plasma and whole-blood assays, prerelease version, were evaluated in South Africa. The precision, accuracy, linearity, and agreement of the Liat HIV Quant whole-blood and plasma assays were compared to those of reference technologies (Roche CAP CTMv2.0 and Abbott RealTime HIV-1) on an HIV verification plasma panel (n = 42) and HIV clinical specimens (n = 163). HIV Quant plasma assay showed good performance, with a 2.7% similarity coefficient of variation (CV) compared to the Abbott assay and a 1.8% similarity CV compared to the Roche test on the verification panel, and 100% specificity. HIV Quant plasma had substantial agreement (pc [concordance correlation] = 0.96) with Roche on clinical specimens and increased variability (pc = 0.73) in the range of <3.0 log copies/ml range with the HIV Quant whole-blood assay. HIV Quant plasma assay had good linearity (2.0 to 5.0 log copies/ml; R(2) = 0.99). Clinical sensitivity at a viral load of 1,000 copies/ml of the HIV Quant plasma and whole-blood assays compared to that of the Roche assay (n = 94) was 100% (confidence interval [CI], 95.3% to 100%). The specificity of HIV Quant plasma was 88.2% (CI, 63.6% to 98.5%), and that for whole blood was 41.2% (CI, 18.4% to 67.1%). No virological failure (downward misclassification) was missed. Liat HIV Quant plasma assay can be interchanged with existing VL technology in South Africa. Liat HIV Quant whole-blood assay would be advantageous for POC early infant diagnosis at birth and adult adherence monitoring and needs to be evaluated further in this clinical context. LIAT cartridges currently require cold storage, but the technology is user-friendly and robust. Clinical cost and
Gous, Natasha; Carmona, Sergio; Stevens, Wendy
2015-01-01
Point-of-care (POC) HIV viral load (VL) testing offers the potential to reduce turnaround times for antiretroviral therapy monitoring, offer near-patient acute HIV diagnosis in adults, extend existing centralized VL services, screen women in labor, and prompt pediatrics to early treatment. The Liat HIV Quant plasma and whole-blood assays, prerelease version, were evaluated in South Africa. The precision, accuracy, linearity, and agreement of the Liat HIV Quant whole-blood and plasma assays were compared to those of reference technologies (Roche CAP CTMv2.0 and Abbott RealTime HIV-1) on an HIV verification plasma panel (n = 42) and HIV clinical specimens (n = 163). HIV Quant plasma assay showed good performance, with a 2.7% similarity coefficient of variation (CV) compared to the Abbott assay and a 1.8% similarity CV compared to the Roche test on the verification panel, and 100% specificity. HIV Quant plasma had substantial agreement (pc [concordance correlation] = 0.96) with Roche on clinical specimens and increased variability (pc = 0.73) in the range of <3.0 log copies/ml range with the HIV Quant whole-blood assay. HIV Quant plasma assay had good linearity (2.0 to 5.0 log copies/ml; R2 = 0.99). Clinical sensitivity at a viral load of 1,000 copies/ml of the HIV Quant plasma and whole-blood assays compared to that of the Roche assay (n = 94) was 100% (confidence interval [CI], 95.3% to 100%). The specificity of HIV Quant plasma was 88.2% (CI, 63.6% to 98.5%), and that for whole blood was 41.2% (CI, 18.4% to 67.1%). No virological failure (downward misclassification) was missed. Liat HIV Quant plasma assay can be interchanged with existing VL technology in South Africa. Liat HIV Quant whole-blood assay would be advantageous for POC early infant diagnosis at birth and adult adherence monitoring and needs to be evaluated further in this clinical context. LIAT cartridges currently require cold storage, but the technology is user-friendly and robust. Clinical cost and
Point-of-care HIV tests done by peers, Brazil
Dutra de Barros, Clarissa Habckost; Lobo, Tainah Dourado de Miranda; Pasini, Elisiane Nelcina; Comparini, Regina Aparecida; Caldas de Mesquita, Fábio
2016-01-01
Abstract Problem Early diagnosis of infections with human immunodeficiency virus (HIV) is needed – especially among key populations such as sex workers, transgender people, men who have sex with men and people who use drugs. Approach The Brazilian Ministry of Health developed a strategy called Viva Melhor Sabendo (“live better knowing”) to increase HIV testing among key populations. In partnership with nongovernmental organizations (NGOs), a peer point-of-care testing intervention, using an oral fluid rapid test, was introduced at social venues for key populations at different times of the day. Local setting Key populations in Brazil can have 40 times higher HIV prevalence than the general population (14.8% versus 0.4%). Relevant changes Legislation was reinterpreted, so that oral fluid rapid tests could be administered by any person trained in rapid testing by the health ministry. Between January 2014 and March 2015, 29 723 oral fluid tests were administered; 791 (2.7%) were positive. Among the key populations, transgender people had the greatest proportion of positive results (10.7%; 172/1612), followed by men who declared themselves as commercial sex workers (8.7%; 165/1889) and men who have sex with men (4.8%; 292/6055). Lessons learnt The strategy improved access to HIV testing. Testing done by peers at times and locations suitable for key populations increased acceptance of testing. Working with relevant NGOs is a useful approach when reaching out to these key populations. PMID:27516641
NASA Astrophysics Data System (ADS)
Goulsbra, Claire; Evans, Martin; Allott, Tim; Evans, Chris; Flint, Rebecca; Mcmorron, Katherine
2014-05-01
In eroding peatland systems POC is the dominant component of the fluvial carbon flux, with POC flux to up to circa 80 g C m-2 yr-1. The fate of this POC has remained uncertain, however, and at present many carbon models exclude POC flux from estimations of atmospherically active carbon budgets. Recent work on headwater systems with high POC concentrations has demonstrated that POC:DOC ratios decrease rapidly downstream, hypothesised to be due the physical and microbial breakdown of POC in the fluvial system and transformation of soil carbon to dissolved and gaseous phases. To assess this hypothesis, laboratory investigations of the potential for transformation of POC to dissolved and gaseous forms were undertaken. POC derived from an exposed gully face was mixed with stream waters collected from Upper North Grain, an eroded peatland catchment in the South Pennines, UK, to simulate typical storm flow suspended sediment concentrations. The solutions were agitated using a magnetic stirring system for one week and subsamples of the solution were extracted at intervals of 0.5, 1, 1.5, 2, 3, 4, 5 and 6 hours, and 1, 2, 3, 4, and 7 days. Samples were analysed for POC and DOC concentration using a Shimadzu total carbon analyser and absorbance was measured spectrophotometrically at 254, 400 465 and 665 nm wavelengths as a proxy for DOC quality. In a parallel experiment CO2 emissions to the mixing flask were measured using an infra-red gas analyser (IRGA). To isolate the role of microbial versus physical breakdown, both experiments were replicated with POM and streamwater which had been sterilised by gamma irradiation. The experiments were further repeated to assess the impact of variations in pH and the initial DOC concentration of the stream water on rates of POC conversion to on DOC and CO2. The results of these experiments will be presented here. Initial results show that peat-derived POC was found to be reactive in streamwater, leading to a rapid in DOC within 24 hours
HIV Point-of-Care Testing in Canadian Settings: A Scoping Review.
Minichiello, Alexa; Swab, Michelle; Chongo, Meck; Marshall, Zack; Gahagan, Jacqueline; Maybank, Allison; Hot, Aurélie; Schwandt, Michael; Gaudry, Sonia; Hurley, Oliver; Asghari, Shabnam
2017-01-01
HIV point-of-care testing (POCT) was approved for use in Canada in 2005 and provides important public health benefits by providing rapid screening results rather than sending a blood sample to a laboratory and waiting on test results. Access to test results soon after testing (or during the same visit) is believed to increase the likelihood that individuals will receive their results and improve access to confirmatory testing and linkages to care. This paper reviews the literature on the utilization of HIV POCT across Canadian provinces. We searched OVID Medline, Embase, EBM Reviews, PsycINFO, CINAHL, and 20 electronic grey literature databases. All empirical studies investigating HIV POCT programs in Canada published in French or English were included. Searches of academic databases identified a total of 6,091 records. After removing duplicates and screening for eligibility, 27 records were included. Ten studies are peer-reviewed articles, and 17 are grey literature reports. HIV POCT in Canada is both feasible and accepted by Canadians. It is preferred to conventional HIV testing (ranging from 81.1 to 97%), and users are highly satisfied with the testing process (ranging between 96 and 100%). The majority of studies demonstrate that HIV POCT is feasible, preferred, and accepted by diverse populations in Canada. Losses to follow-up and linkage rates are also good. However, more research is needed to understand how best to scale up HIV POCT in contexts that currently have very limited or no access to testing.
Rick, Fernanda; Niyibizi, Aline Aurore; Shroufi, Amir; Onami, Kazumi; Steele, Sarah-Jane; Kuleile, Malehlohonolo; Muleya, Innocent; Chiller, Tom; Walker, Tiffany; Van Cutsem, Gilles
2017-01-01
Cryptococcal meningitis is one of the leading causes of death among people with HIV in Africa, primarily due to delayed presentation, poor availability and high cost of treatment. Routine cryptococcal antigen (CrAg) screening of patients with a CD4 count less than 100 cells/mm3, followed by pre-emptive therapy if positive, might reduce mortality in high prevalence settings. Using the cryptococcal antigen (CrAg) lateral flow assay (LFA), screening is possible at the point of care (POC). However, critical shortages of health staff may limit adoption. This study investigates the feasibility of lay counsellors conducting CrAg LFA screening in rural primary care clinics in Lesotho. From May 2014 to June 2015, individuals who tested positive for HIV were tested for CD4 count and those with CD4 <100 cells/mm3 were screened with CrAg LFA. All tests were performed by lay counsellors. CrAg-positive asymptomatic patients received fluconazole, while symptomatic patients were referred to hospital. Lay counsellors were trained and supervised by a laboratory technician and counsellor activity supervisor. Additionally, nurses and doctors were trained on CrAg screening and appropriate treatment. During the study period, 1,388 people were newly diagnosed with HIV, of whom 129 (9%) presented with a CD4 count <100 cells/mm3. Of these, 128 (99%) were screened with CrAg LFA and 14/128 (11%) tested positive. Twelve of the 14 (86%) were asymptomatic, and received outpatient fluconazole. All commenced ART with a median time to initiation of 15.5 days [IQR: 14-22]. Of the asymptomatic patients, nine (75%) remained asymptomatic after a median time of 5 months [IQR; 3-6] of follow up. One (8%) became co-infected with tuberculosis and died and two were transferred out. The two patients with symptomatic cryptococcal meningitis (CM) were referred to hospital, where they later died. CrAg LFA screening by lay counsellors followed by pre-emptive fluconazole treatment for asymptomatic cases, or
Rick, Fernanda; Niyibizi, Aline Aurore; Shroufi, Amir; Onami, Kazumi; Steele, Sarah-Jane; Kuleile, Malehlohonolo; Muleya, Innocent; Chiller, Tom; Walker, Tiffany; Van Cutsem, Gilles
2017-01-01
Introduction Cryptococcal meningitis is one of the leading causes of death among people with HIV in Africa, primarily due to delayed presentation, poor availability and high cost of treatment. Routine cryptococcal antigen (CrAg) screening of patients with a CD4 count less than 100 cells/mm3, followed by pre-emptive therapy if positive, might reduce mortality in high prevalence settings. Using the cryptococcal antigen (CrAg) lateral flow assay (LFA), screening is possible at the point of care (POC). However, critical shortages of health staff may limit adoption. This study investigates the feasibility of lay counsellors conducting CrAg LFA screening in rural primary care clinics in Lesotho. Methods From May 2014 to June 2015, individuals who tested positive for HIV were tested for CD4 count and those with CD4 <100 cells/mm3 were screened with CrAg LFA. All tests were performed by lay counsellors. CrAg-positive asymptomatic patients received fluconazole, while symptomatic patients were referred to hospital. Lay counsellors were trained and supervised by a laboratory technician and counsellor activity supervisor. Additionally, nurses and doctors were trained on CrAg screening and appropriate treatment. Results During the study period, 1,388 people were newly diagnosed with HIV, of whom 129 (9%) presented with a CD4 count <100 cells/mm3. Of these, 128 (99%) were screened with CrAg LFA and 14/128 (11%) tested positive. Twelve of the 14 (86%) were asymptomatic, and received outpatient fluconazole. All commenced ART with a median time to initiation of 15.5 days [IQR: 14–22]. Of the asymptomatic patients, nine (75%) remained asymptomatic after a median time of 5 months [IQR; 3–6] of follow up. One (8%) became co-infected with tuberculosis and died and two were transferred out. The two patients with symptomatic cryptococcal meningitis (CM) were referred to hospital, where they later died. Conclusions CrAg LFA screening by lay counsellors followed by pre
Oxadiazole-carbazole polymer (POC)-Ir(ppy)3 tunable emitting composites
NASA Astrophysics Data System (ADS)
Bruno, Annalisa; Borriello, Carmela; Di Luccio, Tiziana; Sessa, Lucia; Concilio, Simona; Haque, Saif A.; Minarini, Carla
2017-04-01
POC polymer is an oxadiazole-carbazole copolymer we have previously synthetized and established as light emitting material in Organic Light Emitting Devices (OLEDs), although POC quantum yield emission efficiency and color purity still need to be enhanced. On the other hand, tris[2-phenylpyridinato-C2,N]iridium(III) (Ir(ppy)3) complexes, namely Ir(ppy)3 are among the brightest luminophores employed in green light emitting devices. Our aim, in this work, is to take advantage of Ir(ppy)3 bright emission by combining the Ir complex with blue emitting POC to obtain tunable light emitting composites over a wide range of the visible spectrum. Here we have investigated the optical proprieties POC based nanocomposites with different concentrations of Ir(ppy)3, ranging from 1 to 10 wt%. Both spectral and time resolved fluorescence measurements show an efficient energy transfer from the polymer to the dopants, resulting in white-emitting composites. The most intense and stable emission has been found when POC was doped with about 5 wt% concentration of Ir(ppy)3.
Rapid Point-Of-Care Breath Test for Biomarkers of Breast Cancer and Abnormal Mammograms
Phillips, Michael; Beatty, J. David; Cataneo, Renee N.; Huston, Jan; Kaplan, Peter D.; Lalisang, Roy I.; Lambin, Philippe; Lobbes, Marc B. I.; Mundada, Mayur; Pappas, Nadine; Patel, Urvish
2014-01-01
Background Previous studies have reported volatile organic compounds (VOCs) in breath as biomarkers of breast cancer and abnormal mammograms, apparently resulting from increased oxidative stress and cytochrome p450 induction. We evaluated a six-minute point-of-care breath test for VOC biomarkers in women screened for breast cancer at centers in the USA and the Netherlands. Methods 244 women had a screening mammogram (93/37 normal/abnormal) or a breast biopsy (cancer/no cancer 35/79). A mobile point-of-care system collected and concentrated breath and air VOCs for analysis with gas chromatography and surface acoustic wave detection. Chromatograms were segmented into a time series of alveolar gradients (breath minus room air). Segmental alveolar gradients were ranked as candidate biomarkers by C-statistic value (area under curve [AUC] of receiver operating characteristic [ROC] curve). Multivariate predictive algorithms were constructed employing significant biomarkers identified with multiple Monte Carlo simulations and cross validated with a leave-one-out (LOO) procedure. Results Performance of breath biomarker algorithms was determined in three groups: breast cancer on biopsy versus normal screening mammograms (81.8% sensitivity, 70.0% specificity, accuracy 79% (73% on LOO) [C-statistic value], negative predictive value 99.9%); normal versus abnormal screening mammograms (86.5% sensitivity, 66.7% specificity, accuracy 83%, 62% on LOO); and cancer versus no cancer on breast biopsy (75.8% sensitivity, 74.0% specificity, accuracy 78%, 67% on LOO). Conclusions A pilot study of a six-minute point-of-care breath test for volatile biomarkers accurately identified women with breast cancer and with abnormal mammograms. Breath testing could potentially reduce the number of needless mammograms without loss of diagnostic sensitivity. PMID:24599224
Colon-Franco, Jessica Marie; Lo, Stanley F; Tarima, Sergey S; Gourlay, David; Drendel, Amy L; Brook Lerner, E
2017-05-01
Lactate is commonly used in septic patients and is a viable biomarker for trauma patients. Its pre-hospital use could assist triaging and managing patients with these conditions. We evaluated the analytical performance of the point-of-care (POC) StatStrip Xpress Lactate Meter (Nova Biomedical) and compared it to the ABL 800 (Radiometer). We measured lactate in 250 adult and 250 pediatric whole blood samples in 2 laboratories. The performance of the POC meter was assessed by traditional linear regression and Bland-Altman plots, and locally-smoothed (LS) median absolute difference and maximum absolute difference (MAD and MaxAD) curves. The StatStrip was linear with acceptable reproducibility at clinically relevant concentrations. Correlation with the ABL800 showed a negative bias for both populations with slope, bias ±SD (% bias) of 0.78, -0.4±0.7 (-14.5%) in children and 0.80-0.3±0.6 (-13.3%) in adults. The proportional bias appeared more significant at concentrations >4mmol/l (36.0mg/dl). The StatStrip misclassified 7.6 and 8.8% pediatric and adult samples, respectively, to lower risk categories defined using guidelines driven cut-offs. The LS MAD curves identified one breakout, concentration where the LS MAD exceeds the total allowable error limit of 0.3mmol/l (2.7mg/dl), at lactate concentrations of 3.8 and 3.2mmol/l (34.2 and 28.8mg/dl) in the pediatric and adult curves, respectively. Breakthroughs, points at which the LS MaxAD curve exceeds the 95th percentile of MaxADs, occur at concentrations above 7.5mmol/l (67.6mg/dl) for both populations where the performance of the POC meter became erratic. We concluded that if serial lactate measurements are performed, the same method should be used for baseline and follow up measurements. The LS MAD and LS MaxAD curves allowed visual and quantitative mapping of the performance of the lactate POC meter over the range of concentrations measured. This approach seems useful for the identification of points at which the
International definition of a point-of-care test in family practice: a modified e-Delphi procedure.
Schols, Angel M R; Dinant, Geert-Jan; Hopstaken, Rogier; Price, Christopher P; Kusters, Ron; Cals, Jochen W L
2018-01-29
The use of point-of-care tests (POCTs) in family practice is increasing, and the term POCT is often used in medical literature and clinical practice. Yet, no widely supported definition by several professional fields exists. To reach consensus on an international definition of a POCT in family practice. We performed a modified international e-Delphi procedure of four rounds among expert panel members from different professional backgrounds-family practitioners, laboratory specialists, policymakers, researchers and manufacturers. Of 27 panel members from seven different countries, 26 participated in all rounds. Most panel members were active in POCT research or policymaking and 70% worked in family medicine. After choosing important components, structuring of answers and feedback, the following definition was chosen as the best or second best definition by 81% of panel members: a point-of-care test in family practice is a test to support clinical decision making, which is performed by a qualified member of the practice staff nearby the patient and on any part of the patient's body or its derivatives, during or very close to the time of consultation, to help the patient and physician to decide upon the best suited approach, and of which the results should be known at the time of the clinical decision making. The definition emerging from this study can inform family practitioners, laboratory specialists, policymakers and manufacturers on the most widely supported and recognized definition and could act as a clear starting point for the organization and execution of professional point-of-care testing in family practice worldwide. © The Author(s) 2018. Published by Oxford University Press. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
Membrane-based, sedimentation-assisted plasma separator for point-of-care applications.
Liu, Changchun; Mauk, Michael; Gross, Robert; Bushman, Frederic D; Edelstein, Paul H; Collman, Ronald G; Bau, Haim H
2013-11-05
Often, high-sensitivity, point-of-care (POC) clinical tests, such as HIV viral load, require large volumes of plasma. Although centrifuges are ubiquitously used in clinical laboratories to separate plasma from whole blood, centrifugation is generally inappropriate for on-site testing. Suitable alternatives are not readily available to separate the relatively large volumes of plasma from milliliters of blood that may be needed to meet stringent limit-of-detection specifications for low-abundance target molecules. We report on a simple-to-use, low-cost, pump-free, membrane-based, sedimentation-assisted plasma separator capable of separating a relatively large volume of plasma from undiluted whole blood within minutes. This plasma separator consists of an asymmetric, porous, polysulfone membrane housed in a disposable chamber. The separation process takes advantage of both gravitational sedimentation of blood cells and size exclusion-based filtration. The plasma separator demonstrated a "blood in-plasma out" capability, consistently extracting 275 ± 33.5 μL of plasma from 1.8 mL of undiluted whole blood within less than 7 min. The device was used to separate plasma laden with HIV viruses from HIV virus-spiked whole blood with recovery efficiencies of 95.5% ± 3.5%, 88.0% ± 9.5%, and 81.5% ± 12.1% for viral loads of 35,000, 3500, and 350 copies/mL, respectively. The separation process is self-terminating to prevent excessive hemolysis. The HIV-laden plasma was then injected into our custom-made microfluidic chip for nucleic acid testing and was successfully subjected to reverse-transcriptase loop-mediated isothermal amplification (RT-LAMP), demonstrating that the plasma is sufficiently pure to support high-efficiency nucleic acid amplification.
Hata, Kiyomi
2014-12-01
With the rising number of patients who rely on medical care, it is necessary to use evolving health care technology appropriately, to control health care costs, and to enhance the well-being of patients in the home care setting. Point of care testing (POCT)is instrumental system for such demands for home care; however, this term remains relatively unknown in Japan. For this research, I conducted a qualitative analysis of factors based on stories obtained through group interviews of 11 experienced home visiting nurses who work at three home-visit nursing stations for the purpose of clarifying issues in the introduction of POCT. The results of the research identified five categories and 16 subcategories for issues in the introduction of POCT. The identified categories are expected to be useful for the spread of POCT in the future. Key words: Point of care testing, Home care nursing.
Warner, Matthew A; Welsby, Ian J; Norris, Phillip J; Silliman, Christopher C; Armour, Sarah; Wittwer, Erica D; Santrach, Paula J; Meade, Laurie A; Liedl, Lavonne M; Nieuwenkamp, Chelsea M; Douthit, Brian; van Buskirk, Camille M; Schulte, Phillip J; Carter, Rickey E; Kor, Daryl J
2017-08-18
The transfusion-related respiratory complications, transfusion-related acute lung injury (TRALI) and transfusion-associated circulatory overload (TACO), are leading causes of transfusion-related morbidity and mortality. At present, there are no effective preventive strategies with red blood cell (RBC) transfusion. Although mechanisms remain incompletely defined, soluble biological response modifiers (BRMs) within the RBC storage solution may play an important role. Point-of-care (POC) washing of allogeneic RBCs may remove these BRMs, thereby mitigating their impact on post-transfusion respiratory complications. This is a multicenter randomised clinical trial of standard allogeneic versus washed allogeneic RBC transfusion for adult patients undergoing cardiac surgery testing the hypothesis that POC RBC washing is feasible, safe, and efficacious and will reduce recipient immune and physiologic responses associated with transfusion-related respiratory complications. Relevant clinical outcomes will also be assessed. This investigation will enrol 170 patients at two hospitals in the USA. Simon's two-stage design will be used to assess the feasibility of POC RBC washing. The primary safety outcomes will be assessed using Wilcoxon Rank-Sum tests for continuous variables and Pearson chi-square test for categorical variables. Standard mixed modelling practices will be employed to test for changes in biomarkers of lung injury following transfusion. Linear regression will assess relationships between randomised group and post-transfusion physiologic measures. Safety oversight will be conducted under the direction of an independent Data and Safety Monitoring Board (DSMB). Approval of the protocol was obtained by the DSMB as well as the institutional review boards at each institution prior to enrolling the first study participant. This study aims to provide important information regarding the feasibility of POC washing of allogeneic RBCs and its potential impact on ameliorating
Emerging technologies for monitoring drug-resistant tuberculosis at the point-of-care.
Mani, Vigneshwaran; Wang, ShuQi; Inci, Fatih; De Libero, Gennaro; Singhal, Amit; Demirci, Utkan
2014-11-30
Infectious diseases are the leading cause of death worldwide. Among them, tuberculosis (TB) remains a major threat to public health, exacerbated by the emergence of multiple drug-resistant (MDR) and extensively drug-resistant (XDR) Mycobacterium tuberculosis (Mtb). MDR-Mtb strains are resistant to first-line anti-TB drugs such as isoniazid and rifampicin; whereas XDR-Mtb strains are resistant to additional drugs including at least to any fluoroquinolone and one of the second-line anti-TB injectable drugs such as kanamycin, capreomycin, or amikacin. Clinically, these strains have significantly impacted the management of TB in high-incidence developing countries, where systemic surveillance of TB drug resistance is lacking. For effective management of TB on-site, early detection of drug resistance is critical to initiate treatment, to reduce mortality, and to thwart drug-resistant TB transmission. In this review, we discuss the diagnostic challenges to detect drug-resistant TB at the point-of-care (POC). Moreover, we present the latest advances in nano/microscale technologies that can potentially detect TB drug resistance to improve on-site patient care. Copyright © 2014 Elsevier B.V. All rights reserved.
An easy-to-build, low-budget point-of-care ultrasound simulator: from Linux to a web-based solution.
Damjanovic, Domagoj; Goebel, Ulrich; Fischer, Benedikt; Huth, Martin; Breger, Hartmut; Buerkle, Hartmut; Schmutz, Axel
2017-12-01
Hands-on training in point-of-care ultrasound (POC-US) should ideally comprise bedside teaching, as well as simulated clinical scenarios. High-fidelity phantoms and portable ultrasound simulation systems are commercially available, however, at considerable costs. This limits their suitability for medical schools. A Linux-based software for Emergency Department Ultrasound Simulation (edus2TM) was developed by Kulyk and Olszynski in 2011. Its feasibility for POC-US education has been well-documented, and shows good acceptance. An important limitation to an even more widespread use of edus2, however, may be due to the need for a virtual machine for WINDOWS ® systems. Our aim was to adapt the original software toward an HTML-based solution, thus making it affordable and applicable in any simulation setting. We created an HTML browser-based ultrasound simulation application, which reads the input of different sensors, triggering an ultrasound video to be displayed on a respective device. RFID tags, NFC tags, and QR Codes™ have been integrated into training phantoms or were attached to standardized patients. The RFID antenna was hidden in a mock ultrasound probe. The application is independent from the respective device. Our application was used successfully with different trigger/scanner combinations and mounted readily into simulated training scenarios. The application runs independently from operating systems or electronic devices. This low-cost, browser-based ultrasound simulator is easy-to-build, very adaptive, and independent from operating systems. It has the potential to facilitate POC-US training throughout the world, especially in resource-limited areas.
hPOC5 is a centrin-binding protein required for assembly of full-length centrioles.
Azimzadeh, Juliette; Hergert, Polla; Delouvée, Annie; Euteneuer, Ursula; Formstecher, Etienne; Khodjakov, Alexey; Bornens, Michel
2009-04-06
Centrin has been shown to be involved in centrosome biogenesis in a variety of eukaryotes. In this study, we characterize hPOC5, a conserved centrin-binding protein that contains Sfi1p-like repeats. hPOC5 is localized, like centrin, in the distal portion of human centrioles. hPOC5 recruitment to procentrioles occurs during G2/M, a process that continues up to the full maturation of the centriole during the next cell cycle and is correlated with hyperphosphorylation of the protein. In the absence of hPOC5, RPE1 cells arrest in G1 phase, whereas HeLa cells show an extended S phase followed by cell death. We show that hPOC5 is not required for the initiation of procentriole assembly but is essential for building the distal half of centrioles. Interestingly, the hPOC5 family reveals an evolutionary divergence between vertebrates and organisms like Drosophila melanogaster or Caenorhabditis elegans, in which the loss of hPOC5 may correlate with the conspicuous differences in centriolar structure.
Point-of-care oral-based diagnostics
Hart, RW; Mauk, MG; Liu, C; Qiu, X; Thompson, JA; Chen, D; Malamud, D; Abrams, WR; Bau, HH
2014-01-01
Many of the target molecules that reside in blood are also present in oral fluids, albeit at lower concentrations. Oral fluids are, however, relatively easy and safe to collect without the need for specialized equipment and training. Thus, oral fluids provide convenient samples for medical diagnostics. Recent advances in lab-on-a-chip technologies have made minute, fully integrated diagnostic systems practical for an assortment of point-of-care tests. Such systems can perform either immunoassays or molecular diagnostics outside centralized laboratories within time periods ranging from minutes to an hour. The article briefly reviews recent advances in devices for point-of-care testing with a focus on work that has been carried out by the authors as part of a NIH program. PMID:21521419
Novel POC1A mutation in primordial dwarfism reveals new insights for centriole biogenesis.
Koparir, Asuman; Karatas, Omer F; Yuceturk, Betul; Yuksel, Bayram; Bayrak, Ali O; Gerdan, Omer F; Sagiroglu, Mahmut S; Gezdirici, Alper; Kirimtay, Koray; Selcuk, Ece; Karabay, Arzu; Creighton, Chad J; Yuksel, Adnan; Ozen, Mustafa
2015-10-01
POC1A encodes a WD repeat protein localizing to centrioles and spindle poles and is associated with short stature, onychodysplasia, facial dysmorphism and hypotrichosis (SOFT) syndrome. These main features are related to the defect in cell proliferation of chondrocytes in growth plate. In the current study, we aimed at identifying the molecular basis of two patients with primordial dwarfism (PD) in a single family through utilization of whole-exome sequencing. A novel homozygous p.T120A missense mutation was detected in POC1A in both patients, a known causative gene of SOFT syndrome, and confirmed using Sanger sequencing. To test the pathogenicity of the detected mutation, primary fibroblast cultures obtained from the patients and a control individual were used. For evaluating the global gene expression profile of cells carrying p.T120A mutation in POC1A, we performed the gene expression array and compared their expression profiles to those of control fibroblast cells. The gene expression array analysis showed that 4800 transcript probes were significantly deregulated in cells with p.T120A mutation in comparison to the control. GO term association results showed that deregulated genes are mostly involved in the extracellular matrix and cytoskeleton. Furthermore, the p.T120A missense mutation in POC1A caused the formation of abnormal mitotic spindle structure, including supernumerary centrosomes, and changes in POC1A were accompanied by alterations in another centrosome-associated WD repeat protein p80-katanin. As a result, we identified a novel mutation in POC1A of patients with PD and showed that this mutation causes the formation of multiple numbers of centrioles and multipolar spindles with abnormal chromosome arrangement. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Scheuner, Maren T; Peredo, Jane; Tangney, Kelly; Schoeff, Diane; Sale, Taylor; Lubick-Goldzweig, Caroline; Hamilton, Alison; Hilborne, Lee; Lee, Martin; Mittman, Brian; Yano, Elizabeth M; Lubin, Ira M
2017-01-01
To determine whether electronic health record (EHR) tools improve documentation of pre- and postanalytic care processes for genetic tests ordered by nongeneticists. We conducted a nonrandomized, controlled, pre-/postintervention study of EHR point-of-care tools (informational messages and template report) for three genetic tests. Chart review assessed documentation of genetic testing processes of care, with points assigned for each documented item. Multiple linear and logistic regressions assessed factors associated with documentation. Preimplementation, there were no significant site differences (P > 0.05). Postimplementation, mean documentation scores increased (5.9 (2.1) vs. 5.0 (2.2); P = 0.0001) and records with clinically meaningful documentation increased (score >5: 59 vs. 47%; P = 0.02) at the intervention versus the control site. Pre- and postimplementation, a score >5 was positively associated with abnormal test results (OR = 4.0; 95% CI: 1.8-9.2) and trainee provider (OR = 2.3; 95% CI: 1.2-4.6). Postimplementation, a score >5 was also positively associated with intervention site (OR = 2.3; 95% CI: 1.1-5.1) and specialty clinic (OR = 2.0; 95% CI: 1.1-3.6). There were also significantly fewer tests ordered after implementation (264/100,000 vs. 204/100,000; P = 0.03), with no significant change at the control site (280/100,000 vs. 257/100,000; P = 0.50). EHR point-of-care tools improved documentation of genetic testing processes and decreased utilization of genetic tests commonly ordered by nongeneticists.Genet Med 19 1, 112-120.
Robinson, Charlotte S; Sharp, Patrick
2012-05-01
Blood glucose monitoring systems (BGMS) are used in the hospital environment to manage blood glucose levels in patients at the bedside. The International Organization for Standardization (ISO) 15197:2003 standard is currently used by regulatory bodies as a minimum requirement for the performance of BGMS, specific to self-testing. There are calls for the tightening of accuracy requirements and implementation of a standard specifically for point-of-care (POC) BGMS. The accuracy of six commonly used BGMS was assessed in a clinical setting, with 108 patients' finger stick capillary samples. Using the accuracy criteria from the existing standard and a range of tightened accuracy criteria, system performance was compared. Other contributors to system performance have been measured, including hematocrit sensitivity and meter error rates encountered in the clinical setting. Five of the six BGMS evaluated met current accuracy criteria within the ISO 15197 standard. Only the Optium Xceed system had >95% of all readings within a tightened criteria of ±12.5% from the reference at glucose levels ≥72 mg/dl (4 mmol/liter) and ±9 mg/dl (0.5 mmol/liter) at glucose levels <72 mg/dl (4 mmol/liter). The Nova StatStrip Xpress had the greatest number of error messages observed; Optium Xceed the least. OneTouch Ultra2, Nova StatStrip Xpress, Accu-Chek Performa, and Contour TS products were all significantly influenced by blood hematocrit levels. From evidence obtained during this clinical evaluation, the Optium Xceed system is most likely to meet future anticipated accuracy standards for POC BGMS. In this clinical study, the results demonstrated the Optium Xceed product to have the highest level of accuracy, to have the lowest occurrence of error messages, and to be least influenced by blood hematocrit levels. © 2012 Diabetes Technology Society.
Llor, Carl; Bjerrum, Lars; Munck, Anders; Cots, Josep M; Hernández, Silvia; Moragas, Ana
2014-12-01
General practitioners (GPs) often feel uncomfortable when patients request an antibiotic when there is likely little benefit. This study evaluates the effect of access to point-of-care tests on decreasing the prescription of antibiotics in respiratory tract infections in subjects who explicitly requested an antibiotic prescription. Spanish GPs registered all cases of respiratory tract infections over a 3-week period before and after an intervention undertaken in 2008 and 2009. Patients with acute sinusitis, pneumonia, and exacerbations of COPD were excluded. Two types of interventions were performed: the full intervention group received prescriber feedback with discussion of the results of the first registry, courses for GPs, guidelines, patient information leaflets, workshops, and access to point-of-care tests (rapid streptococcal antigen detection test and C-reactive protein test); and the partial intervention group underwent all of the above interventions except for the workshop and access to point-of-care tests. A total of 210 GPs were assigned to the full intervention group and 71 to the partial intervention group. A total of 25,479 subjects with respiratory tract infections were included, of whom 344 (1.4%) requested antibiotic prescribing. Antibiotics were more frequently prescribed to subjects requesting them compared with those who did not (49.1% vs 18.5%, P < .001). In the group of GPs assigned to the partial intervention group, 53.1% of subjects requesting antibiotics received a prescription before and 60% after the intervention, without statistical differences being observed. In the group of GPs assigned to the full intervention group, the percentages were 55.1% and 36.2%, respectively, with a difference of 18.9% (95% CI: 6.4%-30.6%, P < .05). Access to point-of-care tests reduces antibiotic use in subjects who explicitly request an antibiotic prescription. Copyright © 2014 by Daedalus Enterprises.
Zhang, Yuanzheng; Fang, Shuo; Dai, Jiezhi; Zhu, Lei; Fan, Hao; Tang, Weiya; Fan, Yongjie; Dai, Haiying; Zhang, Peipei; Wang, Ying; Xing, Xin; Yang, Chao
2017-01-01
To explore the repairing effect of combination of adipose stem cells (ASCs) and composite scaffolds on CWR, the electrospun Poly 1, 8-octanediol-co-citric acid (POC)-poly-L-lactide acid (PLA) composite scaffolds were prepared, followed by in vitro and in vivo biocompatibility evaluation of the scaffolds. Afterwards, ASCs were seeded on POC-PLA to construct the POC-PLA-ASCs scaffolds, and the POC-PLA, POC-PLA-ASCs, and traditional materials expanded polytetrafluoroethylene (ePTFE) were adopt for CWR in New Zealand white (NZW) rabbit models. As results, the POC-PLA-ASCs patches possessed good biocompatibility as the high proliferation ability of cells surrounding the patches. Rabbits in POC-PLA-ASCs groups showed better pulmonary function, less pleural adhesion, higher degradation rate and more neovascularization when compared with that in other two groups. The results of western blot indicated that POC-PLA-ASCs patches accelerated the expression of VEGF and Collagen I in rabbit models. From the above, our present study demonstrated that POC-PLA material was applied for CWR successfully, and ASCs seeded on the sheets could improve the pleural adhesions and promote the reparation of chest wall defects.
Ferreira, Fernanda Teixeira; Fidelis, Thiago André; Pereira, Thiago Almeida; Otoni, Alba; Queiroz, Leonardo Campos; Amâncio, Frederico Figueiredo; Antunes, Carlos Maurício; Lambertucci, José Roberto
2017-01-01
The Kato-Katz technique is the standard diagnostic test for Schistosoma mansoni infection in rural areas. However, the utility of this method is severely limited by the day-to-day variability in host egg excretion in the stool. In high-transmission areas, the point-of-care circulating cathodic antigen (POC-CCA) urine assay has proven to be a reliable test. However, investigations of the reliability of the POC-CCA assay in low-transmission regions are under way. This study aimed to evaluate the sensitivity and specificity of the POC-CCA assay and the morbidity of schistosomiasis in a low-endemic area in Brazil. Pains City is a low-transmission zone for schistosomiasis. A total of 300 subjects aged 7-76 years were randomly selected for the POC-CCA cassette test. For S. mansoni diagnosis, three stool samples on six slides were compared with one urine sample for each subject. The sensitivity and specificity in the absence of a gold standard were calculated using latent class analysis. Clinical examinations and abdominal ultrasounds were performed in 181 volunteers to evaluate morbidity associated with schistosomiasis. The sensitivity and specificity of the Kato-Katz technique were 25.6% and 94.6%, respectively. By contrast, the sensitivity and specificity of the POC-CCA assay were 68.1% and 72.8%, respectively. Hepatosplenic schistosomiasis was diagnosed in two patients (1.1%). Overall, the POC-CCA urine assay proved to be a useful test for diagnosing S. mansoni in a low-endemic area in Brazil. Severe clinical forms of schistosomiasis can be present even in such low-endemic areas.
Where are we at with point-of-care testing in haematology?
Briggs, Carol; Kimber, Simon; Green, Laura
2012-09-01
Point-of-care testing (POCT) in haematology has continued to grow in popularity and uptake throughout the world. The increasing demand to reduce the turnaround time of test results, coupled with rapid improvements in technology, have led to the development of several devices that are designed for use in different clinical settings, with the hope of improving patient care. The most used POCT in haematology is measurement of haemoglobin concentration. Other POCT devices (used primarily in developing countries) for malaria screening and CD4+ T-lymphocytes for quantification of human-immunodeficiency-virus are becoming the cornerstone for the diagnosis and management of these disorders. New devices are also available for red cell indices, white blood cell count and platelets. In this review clinical studies that validate the use of such devices will be discussed, as well as the advantages and disadvantages of POCT in haematology. A disadvantage of POCT is a lack of training, poor standardization in obtaining blood samples and insufficient internal/external quality assessment. As there is every reason to expect that POCT use will increase in all pathology disciplines, including haematology, it is imperative that systems are put in place to oversee these issues. © 2012 Blackwell Publishing Ltd.
Quality assuring HIV point of care testing using whole blood samples.
Dare-Smith, Raellene; Badrick, Tony; Cunningham, Philip; Kesson, Alison; Badman, Susan
2016-08-01
The Royal College of Pathologists Australasia Quality Assurance Programs (RCPAQAP), have offered dedicated external quality assurance (EQA) for HIV point of care testing (PoCT) since 2011. Prior to this, EQA for these tests was available within the comprehensive human immunodeficiency virus (HIV) module. EQA testing for HIV has typically involved the supply of serum or plasma, while in the clinic or community based settings HIV PoCT is generally performed using whole blood obtained by capillary finger-stick collection. RCPAQAP has offered EQA for HIV PoCT using stabilised whole blood since 2014. A total of eight surveys have been undertaken over a period of 2 years from 2014 to 2015. Of the 962 responses received, the overall consensus rate was found to be 98% (941/962). A total of 21 errors were detected. The majority of errors were attributable to false reactive HIV p24 antigen results (9/21, 43%), followed by false reactive HIV antibody results (8/21, 38%). There were 4/21 (19%) false negative HIV antibody results and no false negative HIV p24 antigen results reported. Overall performance was observed to vary minimally between surveys, from a low of 94% up to 99% concordant. Encouraging levels of testing proficiency for HIV PoCT are indicated by these data, but they also confirm the need for HIV PoCT sites to participate in external quality assurance programs to ensure the ongoing provision of high quality patient care. Copyright © 2016 Royal College of Pathologists of Australasia. All rights reserved.
Hempel, Dorothea; Haunhorst, Stephanie; Sinnathurai, Sivajini; Seibel, Armin; Recker, Florian; Heringer, Frank; Michels, Guido; Breitkreutz, Raoul
2016-12-01
Point-of-care ultrasound (POC-US) is gaining importance in almost all specialties. E-learning has been used to teach theoretical knowledge and pattern recognition. As social media are universally available, they can be utilized for educational purposes. We wanted to evaluate the utility of the sandwich e-learning approach defined as a pre-course e-learning and a post-course learning activity using Facebook after a one-day point-of-care ultrasound (POC-US) course and its effect on the retention of knowledge. A total of 62 medial students were recruited for this study and randomly assigned to one of four groups. All groups received an identical hands-on training and performed several tests during the study period. The hands-on training was performed in groups of five students per instructor with the students scanning each other. Group 1 had access to pre-course e-learning, but not to post-course e-learning. Instead of a pre-course e-learning, group 2 listened to presentations at the day of the course (classroom teaching) and had access to the post-course learning activity using Facebook. Group 3 had access to both pre- and post-course e-learning (sandwich e-learning) activities, while group 4 listened classroom presentations only (classroom teaching only). Therefore only groups 2 and 3 had access to post-course learning via Facebook by joining a secured group. Posts containing ultrasound pictures and videos were published to this group. The students were asked to "like" the posts to monitor attendance. Knowledge retention was assessed 6 weeks after the course. After 6 weeks, group 3 achieved comparable results when compared to group 2 (82.2 % + -8.2 vs. 84.3 + -8.02) (p = 0.3). Students who participated in the post-course activity were more satisfied with the overall course than students without post-course learning (5.5 vs. 5.3 on a range from 1 to 6). In this study, the sandwich e-learning approach led to equal rates of knowledge retention compared to
A single FPGA-based portable ultrasound imaging system for point-of-care applications.
Kim, Gi-Duck; Yoon, Changhan; Kye, Sang-Bum; Lee, Youngbae; Kang, Jeeun; Yoo, Yangmo; Song, Tai-kyong
2012-07-01
We present a cost-effective portable ultrasound system based on a single field-programmable gate array (FPGA) for point-of-care applications. In the portable ultrasound system developed, all the ultrasound signal and image processing modules, including an effective 32-channel receive beamformer with pseudo-dynamic focusing, are embedded in an FPGA chip. For overall system control, a mobile processor running Linux at 667 MHz is used. The scan-converted ultrasound image data from the FPGA are directly transferred to the system controller via external direct memory access without a video processing unit. The potable ultrasound system developed can provide real-time B-mode imaging with a maximum frame rate of 30, and it has a battery life of approximately 1.5 h. These results indicate that the single FPGA-based portable ultrasound system developed is able to meet the processing requirements in medical ultrasound imaging while providing improved flexibility for adapting to emerging POC applications.
Pre-implementation guidelines for infectious disease point-of-care testing in medical institutions.
van der Eijk, Annemiek A; Tintu, Andrei N; Hays, John P
2017-01-01
Infectious disease point-of-care test (ID-POCT) devices are becoming widely available, and in this respect, international quality standards and guidelines are available for consultation once ID-POCT has been implemented into medical institutions. However, specific guidelines for consultation during the initial pre-implementation decision-making process are currently lacking. Further, there exist pre-implementation issues specific to ID-POCT. Here we present pre-implementation guidelines for consultation when considering the implementation of ID-POCT in medical institutions.
Horwood, Jeremy; Ingle, Suzanne M; Burton, David; Woodman-Bailey, Adam; Horner, Paddy; Jeal, Nikki
2016-03-01
Guidelines highlight the need to increase HIV testing among men who have sex with men (MSM) and novel point-of-care testing provides new possibilities for delivery of care. However, it is unclear how point-of-care testing should be used to best effect. This study aimed to increase understanding of sexual risk-taking behaviour, service use, and attitudes to point-of-care testing among MSM sauna clients. Data were collected within two saunas for MSM in south west England using a self-completion survey (n = 134). Though this sample of MSM sauna clients are at high risk of acquiring a sexually transmitted infection, the testing frequency among the majority of those reporting unprotected anal intercourse is not in keeping with national guidelines. For almost all participants the introduction of rapid point-of-care testing for both genital and blood-borne infection was likely to increase testing and for the majority NHS specialist services was the preferred setting. © The Author(s) 2016.
Horwood, Jeremy; Ingle, Suzanne M; Burton, David; Woodman-Bailey, Adam; Horner, Paddy
2015-01-01
Guidelines highlight the need to increase HIV testing among men who have sex with men (MSM) and novel point-of-care testing provides new possibilities for delivery of care. However, it is unclear how point-of-care testing should be used to best effect. This study aimed to increase understanding of sexual risk-taking behaviour, service use, and attitudes to point-of-care testing among MSM sauna clients. Data were collected within two saunas for MSM in south west England using a self-completion survey (n = 134). Though this sample of MSM sauna clients are at high risk of acquiring a sexually transmitted infection, the testing frequency among the majority of those reporting unprotected anal intercourse is not in keeping with national guidelines. For almost all participants the introduction of rapid point-of-care testing for both genital and blood-borne infection was likely to increase testing and for the majority NHS specialist services was the preferred setting. PMID:25907347
CMOS Cell Sensors for Point-of-Care Diagnostics
Adiguzel, Yekbun; Kulah, Haluk
2012-01-01
The burden of health-care related services in a global era with continuously increasing population and inefficient dissipation of the resources requires effective solutions. From this perspective, point-of-care diagnostics is a demanded field in clinics. It is also necessary both for prompt diagnosis and for providing health services evenly throughout the population, including the rural districts. The requirements can only be fulfilled by technologies whose productivity has already been proven, such as complementary metal-oxide-semiconductors (CMOS). CMOS-based products can enable clinical tests in a fast, simple, safe, and reliable manner, with improved sensitivities. Portability due to diminished sensor dimensions and compactness of the test set-ups, along with low sample and power consumption, is another vital feature. CMOS-based sensors for cell studies have the potential to become essential counterparts of point-of-care diagnostics technologies. Hence, this review attempts to inform on the sensors fabricated with CMOS technology for point-of-care diagnostic studies, with a focus on CMOS image sensors and capacitance sensors for cell studies. PMID:23112587
CMOS cell sensors for point-of-care diagnostics.
Adiguzel, Yekbun; Kulah, Haluk
2012-01-01
The burden of health-care related services in a global era with continuously increasing population and inefficient dissipation of the resources requires effective solutions. From this perspective, point-of-care diagnostics is a demanded field in clinics. It is also necessary both for prompt diagnosis and for providing health services evenly throughout the population, including the rural districts. The requirements can only be fulfilled by technologies whose productivity has already been proven, such as complementary metal-oxide-semiconductors (CMOS). CMOS-based products can enable clinical tests in a fast, simple, safe, and reliable manner, with improved sensitivities. Portability due to diminished sensor dimensions and compactness of the test set-ups, along with low sample and power consumption, is another vital feature. CMOS-based sensors for cell studies have the potential to become essential counterparts of point-of-care diagnostics technologies. Hence, this review attempts to inform on the sensors fabricated with CMOS technology for point-of-care diagnostic studies, with a focus on CMOS image sensors and capacitance sensors for cell studies.
Valdez-González, Leticia A; Méndez-Padrón, Araceli; Gómez-Díaz, Rita A; Valladares-Salgado, Adán; Sánchez-Becerra, Martha Catalina; Mondragón-González, Rafael; Hernández-Rubí, Jaime; González-Hermosillo, Arturo; Cruz, Miguel; Borja, Víctor; Wacher, Niels H
The albumin-creatinine ratio is considered an indicator of microalbuminuria, precursor to chronic kidney disease, while HbA1c is used to measure glycemic control. Given the prevalence of diabetes-related nephropathy, spot testing of albumin has long been recommended as a preventative measure, for the timely detection of microalbuminuria. However, many countries do not have this testing available in primary care, and sometimes not even in second- and third-level care. The objective of this study was to compare agreement of the microalbuminuria and HbA1c results obtained in the laboratory with 'gold standard' techniques, with those obtained on site with a 'Point of Care' DCA Vantage™ device by Siemens. Results for the albumin-creatinine ratio and HbA1c from the Siemens DCA Vantage™ point of care device were compared with those from standard laboratory tests in 25 family medicine units in Mexico City and Toluca, State of Mexico, in patients diagnosed with type-2 diabetes. Agreement between the albumin values of the 2 tests was 0.745 (CI 95% 0.655-0.812). Agreement between the two measurement techniques for HbA1c was 0.970 (CI 95% 0.966-0.973). The results obtained were sufficiently comparative (R i = 0.74 for albumin-creatinine ratio and R i = 0.97 for HbA1c) to justify the use of the point of care device. Given the high agreement between the point of care device and laboratory tests, this device could be used to identify chronic kidney disease and glycemic control for more adequate treatment in patients with diabetes, especially in remote areas.
Shuster, Sara M.; Davey, Cynthia S.
2014-01-01
Objective: Determine the percentage of subjects taking antipsychotics who meet criteria for metabolic syndrome based on point-of-care testing analyses. Evaluate pharmacist comprehensive medication management services using point-of-care tests to reduce the mean difference in number of metabolic syndrome risk parameters at 6 and 12 months. Method: This 12-month, prospective, multisite, randomized, controlled study included 120 subjects taking antipsychotics (mean [SD] age of 42.9 [11.3] years) recruited from 3 community mental health clinics in Minnesota. Subjects consented to receive either pharmacist (PCS; n = 60) or no pharmacist (NCS; n = 60) comprehensive medication management services. Data were collected from February 2010 to January 2012. Results: No statistical differences in metabolic syndrome based on point-of-care tests were observed between the 2 groups at baseline (PCS: 85.2%, n = 46 versus NCS: 71.2%, n = 42, P = .073) or at 12 months (PCS: 84.4%, n = 38 versus NCS: 70.2%, n = 33, P = .104). Subjects, overall, screened positive at baseline for dyslipidemia (85.8%, n = 106), hypertension (52.5%, n = 63), and diabetes (22.5%, n = 27) based on point-of-care testing for metabolic risk criteria. After 12 months, a nonsignificant (P = .099) higher adjusted mean number of metabolic syndrome parameters in PCS subjects compared to NCS subjects (mean difference [95% CI] = 0.41 [−0.08 to 0.90]) were found. Conclusions: A relatively high proportion of subjects met criteria for metabolic syndrome, although no significant improvement was observed between the groups after 12 months. Point-of-care test analyses identified a high proportion of subjects meeting criteria for dyslipidemia, hypertension, and diabetes. Utilizing point-of-care tests in mental health settings and fostering interprofessional partnerships with comprehensive medication management pharmacists may improve identification and long-term management of metabolic risks among patients prescribed
Raamanathan, Archana; Simmons, Glennon W; Christodoulides, Nicolaos; Floriano, Pierre N; Furmaga, Wieslaw B; Redding, Spencer W; Lu, Karen H; Bast, Robert C; McDevitt, John T
2012-05-01
Point-of-care (POC) implementation of early detection and screening methodologies for ovarian cancer may enable improved survival rates through early intervention. Current laboratory-confined immunoanalyzers have long turnaround times and are often incompatible with multiplexing and POC implementation. Rapid, sensitive, and multiplexable POC diagnostic platforms compatible with promising early detection approaches for ovarian cancer are needed. To this end, we report the adaptation of the programmable bio-nano-chip (p-BNC), an integrated, microfluidic, and modular (programmable) platform for CA125 serum quantitation, a biomarker prominently implicated in multimodal and multimarker screening approaches. In the p-BNCs, CA125 from diseased sera (Bio) is sequestered and assessed with a fluorescence-based sandwich immunoassay, completed in the nano-nets (Nano) of sensitized agarose microbeads localized in individually addressable wells (Chip), housed in a microfluidic module, capable of integrating multiple sample, reagent and biowaste processing, and handling steps. Antibody pairs that bind to distinct epitopes on CA125 were screened. To permit efficient biomarker sequestration in a three-dimensional microfluidic environment, the p-BNC operating variables (incubation times, flow rates, and reagent concentrations) were tuned to deliver optimal analytical performance under 45 minutes. With short analysis times, competitive analytical performance (inter- and intra-assay precision of 1.2% and 1.9% and limit of detection of 1.0 U/mL) was achieved on this minisensor ensemble. Furthermore, validation with sera of patients with ovarian cancer (n = 20) showed excellent correlation (R(2) = 0.97) with gold-standard ELISA. Building on the integration capabilities of novel microfluidic systems programmed for ovarian cancer, the rapid, precise, and sensitive miniaturized p-BNC system shows strong promise for ovarian cancer diagnostics.
Raamanathan, Archana; Simmons, Glennon W.; Christodoulides, Nicolaos; Floriano, Pierre N.; Furmaga, Wieslaw B.; Redding, Spencer W.; Lu, Karen H.; Bast, Robert C.; McDevitt, John T.
2013-01-01
Point-of-care (POC) implementation of early detection and screening methodologies for ovarian cancer may enable improved survival rates through early intervention. Current laboratory-confined immunoanalyzers have long turnaround times and are often incompatible with multiplexing and POC implementation. Rapid, sensitive and multiplexable POC diagnostic platforms compatible with promising early detection approaches for ovarian cancer are needed. To this end, we report the adaptation of the programmable bio-nano-chip (p-BNC), an integrated, microfluidic, modular (Programmable) platform for CA125 serum quantitation, a biomarker prominently implicated in multi-modal and multi-marker screening approaches. In the p-BNC, CA125 from diseased sera (Bio) is sequestered and assessed with a fluorescence-based sandwich immunoassay, completed in the nano-nets (Nano) of sensitized agarose microbeads localized in individually addressable wells (Chip), housed in a microfluidic module, capable of integrating multiple sample, reagent and biowaste processing and handling steps. Antibody pairs that bind to distinct epitopes on CA125 were screened. To permit efficient biomarker sequestration in a 3-D microfluidic environment, the p-BNC operating variables (incubation times, flow rates and reagent concentrations) were tuned to deliver optimal analytical performance under 45 minutes. With short analysis times, competitive analytical performance (Inter- and intra-assay precision of 1.2% and 1.9% and LODs of 1.0 U/mL) was achieved on this mini-sensor ensemble. Further validation with sera of ovarian cancer patients (n=20) demonstrated excellent correlation (R2 = 0.97) with gold-standard ELISA. Building on the integration capabilities of novel microfluidic systems programmed for ovarian cancer, the rapid, precise and sensitive miniaturized p-BNC system shows strong promise for ovarian cancer diagnostics. PMID:22490510
Determination of piezo-optic coefficients of crystals by means of four-point bending.
Krupych, Oleg; Savaryn, Viktoriya; Krupych, Andriy; Klymiv, Ivan; Vlokh, Rostyslav
2013-06-10
A technique developed recently for determining piezo-optic coefficients (POCs) of isotropic optical media, which represents a combination of digital imaging laser interferometry and a classical four-point bending method, is generalized and applied to a single-crystalline anisotropic material. The peculiarities of measuring procedures and data processing for the case of optically uniaxial crystals are described in detail. The capabilities of the technique are tested on the example of canonical nonlinear optical crystal LiNbO3. The high precision achieved in determination of the POCs for isotropic and anisotropic materials testifies that the technique should be both versatile and reliable.
DeRemer, Christina E; McMichael, Bliss; Young, Henry N
2018-01-01
Many factors influence international normalized ratio (INR); however, few studies have examined the impact of anemia in warfarin patients. The primary objective of this study was to explore the relationship between in-clinic anemia and the control of INR within an anticoagulation clinic. A retrospective chart review was performed on a random sample of patients seen in an academic medical center pharmacy-managed anticoagulation clinic. Hemochron® Signature Elite machine was utilized to monitor point-of-care (POC) INR. In-clinic anemia was defined as hematocrit <32%. Statistical analyses were conducted using STATA MP a webbased platform ( https://www.stata.com/statamp/ ). Of the 300 patients analyzed, 45 (15%) patients had in-clinic anemia. Patients with in-clinic anemia were more likely to be younger ( P < .05), female ( P < .05), and have a diagnosis of sickle cell disease or anemia ( P < .05). In the unadjusted logistic regression model, patients with in-clinic anemia were less likely to have an in-range INR ( OR: 0.52; 95% CI: 0.27-0.98). The adjusted regression model did not show significance. Study results suggest that in-clinic anemia may be more prevalent among younger, female patients prescribed warfarin, and patients diagnosed with in-clinic anemia may be a risk factor for out-of-range INR. Pharmacists practicing in anticoagulation clinics can incorporate this information into patient care practice in efforts to maintain optimal management.
Thompson, Matthew; Weigl, Bernhard; Fitzpatrick, Annette; Ide, Nicole
2016-01-01
Current frameworks for evaluating diagnostic tests are constrained by a focus on diagnostic accuracy, and assume that all aspects of the testing process and test attributes are discrete and equally important. Determining the balance between the benefits and harms associated with new or existing tests has been overlooked. Yet, this is critically important information for stakeholders involved in developing, testing, and implementing tests. This is particularly important for point of care tests (POCTs) where tradeoffs exist between numerous aspects of the testing process and test attributes. We developed a new model that multiple stakeholders (e.g., clinicians, patients, researchers, test developers, industry, regulators, and health care funders) can use to visualize the multiple attributes of tests, the interactions that occur between these attributes, and their impacts on health outcomes. We use multiple examples to illustrate interactions between test attributes (test availability, test experience, and test results) and outcomes, including several POCTs. The model could be used to prioritize research and development efforts, and inform regulatory submissions for new diagnostics. It could potentially provide a way to incorporate the relative weights that various subgroups or clinical settings might place on different test attributes. Our model provides a novel way that multiple stakeholders can use to visualize test attributes, their interactions, and impacts on individual and population outcomes. We anticipate that this will facilitate more informed decision making around diagnostic tests.
Chapin, Kimberle C.; Blake, Patricia; Wilson, Claire D.
2002-01-01
Group A streptococcus (GAS) antigen testing has become a routine point-of-care (POC) test in acute care settings. Concern about performance parameters (PP) of these tests as well as inappropriate antibiotic use has resulted in various recommendations regarding diagnosis of GAS. There were two objectives in this study. The first was to evaluate the rapid GAS antigen test presently in use (Thermo BioStar, Boulder, Colo.) and the GAS Direct probe test (Gen-Probe, San Diego, Calif.) compared to culture. The second was to define the optimal use of these technologies in a large acute care pediatric clinic. A total of 520 consecutive pediatric patients presenting with symptoms of pharyngitis at any of three Lahey Clinic acute care facilities were evaluated. Pharyngeal specimens were collected using a double-swab collection device (Copan, Corona, Calif.). One swab was used for the antigen test, the second was used for the probe test, and the pledget was placed in the collection device for culture on 5% sheep blood agar, incubated for 48 h anaerobically, and subsequently placed in Todd-Hewitt broth. After discrepant analysis, sensitivity, specificity, and positive and negative predictive values were as follows: 94.8, 100, 100, and 96.9% for the probe test and 86.1, 97.1, 93.7, and 93.4% for the antigen test, respectively. Sensitivity using an enhanced culture technique was 99.4% (163 of 164). False-positive (FP) antigen results were often seen from patients previously diagnosed and/or treated for GAS. No FP results were seen with the probe test. Colony counts for the false-negative (FN) antigen tests were higher than those for the FN probe tests. Compared to culture and DNA probe, the rapid antigen test (RAT) offered a result at the time of the patient's visit, with acceptable PP when prevalence of disease is high. Follow-up testing with the RAT of GAS patients who previously tested as positive should be avoided due to increased FP results. The probe test was comparable to
A PMMA microfluidic dielectric sensor for blood coagulation monitoring at the point-of-care.
Maji, Debnath; Suster, Michael A; Kucukal, Erdem; Gurkan, Umut A; Stavrou, Evi X; Mohseni, Pedram
2016-08-01
This paper describes the design and construct of a fully biocompatible, microfluidic, dielectric sensor targeted at monitoring human whole blood coagulation at the point-of-care (POC). The sensor assembly procedure involves using sputtered electrodes in a microfluidic channel with a physiologically relevant height of 50μm to create a three-dimensional (3D), parallel-plate, capacitive sensing area. The sensor is constructed with biocompatible materials of polymethyl methacrylate (PMMA) for the substrate and titanium nitride (TiN) for the sensing and floating electrodes. The real part of the complex relative dielectric permittivity of human whole blood is measured from 10kHz to 100MHz using an impedance analyzer and under static conditions. The temporal variation in dielectric permittivity at 1MHz for human whole blood undergoing coagulation shows a peak in permittivity at 5 minutes, which closely matches our previously established results. This sensor can pave the way for monitoring blood coagulation under physiologically relevant shear flow rates in the future.
Natoli, Lisa; Guy, Rebecca J; Shephard, Mark; Causer, Louise; Badman, Steven G; Hengel, Belinda; Tangey, Annie; Ward, James; Coburn, Tony; Anderson, David; Kaldor, John; Maher, Lisa
2015-01-01
Point-of-care tests for chlamydia (CT) and gonorrhoea (NG) could increase the uptake and timeliness of testing and treatment, contribute to improved disease control and reduce reproductive morbidity. The GeneXpert (Xpert CT/NG assay), suited to use at the point-of-care, is being used in the TTANGO randomised controlled trial (RCT) in 12 remote Australian health services with a high burden of sexually transmissible infections (STIs). This represents the first ever routine use of a molecular point-of-care diagnostic for STIs in primary care. The purpose of this study was to explore the acceptability of the GeneXpert to primary care staff in remote Australia. In-depth qualitative interviews were conducted with 16 staff (registered or enrolled nurses and Aboriginal Health Workers/Practitioners) trained and experienced with GeneXpert testing. Interviews were digitally-recorded and transcribed verbatim prior to content analysis. Most participants displayed positive attitudes, indicating the test was both easy to use and useful in their clinical context. Participants indicated that point-of-care testing had improved management of STIs, resulting in more timely and targeted treatment, earlier commencement of partner notification, and reduced follow up efforts associated with client recall. Staff expressed confidence in point-of-care test results and treating patients on this basis, and reported greater job satisfaction. While point-of-care testing did not negatively impact on client flow, several found the manual documentation processes time consuming, suggesting that improved electronic connectivity and test result transfer between the GeneXpert and patient management systems could overcome this. Managing positive test results in a shorter time frame was challenging for some but most found it satisfying to complete episodes of care more quickly. In the context of a RCT, health professionals working in remote primary care in Australia found the GeneXpert highly acceptable
Truncation of POC1A associated with short stature and extreme insulin resistance.
Chen, Jian-Hua; Segni, Maria; Payne, Felicity; Huang-Doran, Isabel; Sleigh, Alison; Adams, Claire; Savage, David B; O'Rahilly, Stephen; Semple, Robert K; Barroso, Inês
2015-10-01
We describe a female proband with primordial dwarfism, skeletal dysplasia, facial dysmorphism, extreme dyslipidaemic insulin resistance and fatty liver associated with a novel homozygous frameshift mutation in POC1A, predicted to affect two of the three protein products of the gene. POC1A encodes a protein associated with centrioles throughout the cell cycle and implicated in both mitotic spindle and primary ciliary function. Three homozygous mutations affecting all isoforms of POC1A have recently been implicated in a similar syndrome of primordial dwarfism, although no detailed metabolic phenotypes were described. Primary cells from the proband we describe exhibited increased centrosome amplification and multipolar spindle formation during mitosis, but showed normal DNA content, arguing against mitotic skipping, cleavage failure or cell fusion. Despite evidence of increased DNA damage in cells with supernumerary centrosomes, no aneuploidy was detected. Extensive centrosome clustering both at mitotic spindles and in primary cilia mitigated the consequences of centrosome amplification, and primary ciliary formation was normal. Although further metabolic studies of patients with POC1A mutations are warranted, we suggest that POC1A may be added to ALMS1 and PCNT as examples of centrosomal or pericentriolar proteins whose dysfunction leads to extreme dyslipidaemic insulin resistance. Further investigation of links between these molecular defects and adipose tissue dysfunction is likely to yield insights into mechanisms of adipose tissue maintenance and regeneration that are critical to metabolic health. © 2015 Society for Endocrinology.
Verbakel, Jan Y; Lemiengre, Marieke B; De Burghgraeve, Tine; De Sutter, An; Aertgeerts, Bert; Shinkins, Bethany; Perera, Rafael; Mant, David; Van den Bruel, Ann; Buntinx, Frank
2016-10-06
Point-of-care blood C-reactive protein (CRP) testing has diagnostic value in helping clinicians rule out the possibility of serious infection. We investigated whether it should be offered to all acutely ill children in primary care or restricted to those identified as at risk on clinical assessment. Cluster randomised controlled trial involving acutely ill children presenting to 133 general practitioners (GPs) at 78 GP practices in Belgium. Practices were randomised to undertake point-of-care CRP testing in all children (1730 episodes) or restricted to children identified as at clinical risk (1417 episodes). Clinical risk was assessed by a validated clinical decision rule (presence of one of breathlessness, temperature ≥ 40 °C, diarrhoea and age 12-30 months, or clinician concern). The main trial outcome was hospital admission with serious infection within 5 days. No specific guidance was given to GPs on interpreting CRP levels but diagnostic performance is reported at 5, 20, 80 and 200 mg/L. Restricting CRP testing to those identified as at clinical risk substantially reduced the number of children tested by 79.9 % (95 % CI, 77.8-82.0 %). There was no significant difference between arms in the number of children with serious infection who were referred to hospital immediately (0.16 % vs. 0.14 %, P = 0.88). Only one child with a CRP < 5 mg/L had an illness requiring admission (a child with viral gastroenteritis admitted for rehydration). However, of the 80 children referred to hospital to rule out serious infection, 24 (30.7 %, 95 % CI, 19.6-45.6 %) had a CRP < 5 mg/L. CRP testing should be restricted to children at higher risk after clinical assessment. A CRP < 5 mg/L rules out serious infection and could be used by GPs to avoid unnecessary hospital referrals. ClinicalTrials.gov Identifier: NCT02024282 (registered on 14 th September 2012).
O'Brien, J A
2000-12-01
Is POCT worth integrating into a facility? Despite its promise of speed and convenience, this technology requires careful evaluation of potential benefits, disadvantages, and challenges to the existing system. If the pros outweigh the cons, a step-by-step approach can ease the process of implementing a POCT program.
Direct writing electrodes using a ball pen for paper-based point-of-care testing.
Li, Zedong; Li, Fei; Hu, Jie; Wee, Wei Hong; Han, Yu Long; Pingguan-Murphy, Belinda; Lu, Tian Jian; Xu, Feng
2015-08-21
The integration of paper with an electrochemical device has attracted growing attention for point-of-care testing, where it is of great importance to fabricate electrodes on paper in a low-cost, easy and versatile way. In this work, we report a simple strategy for directly writing electrodes on paper using a pressure-assisted ball pen to form a paper-based electrochemical device (PED). This method is demonstrated to be capable of fabricating electrodes on paper with good electrical conductivity and electrochemical performance, holding great potential to be employed in point-of-care applications, such as in human health diagnostics and food safety detection. As examples, the PEDs fabricated using the developed method are applied for detection of glucose in artificial urine and melamine in sample solutions. Furthermore, our developed strategy is also extended to fabricate PEDs with multi-electrode arrays and write electrodes on non-planar surfaces (e.g., paper cup, human skin), indicating the potential application of our method in other fields, such as fabricating biosensors, paper electronics etc.
Advances Afoot in Microbiology.
Patel, Robin; Karon, Brad S
2017-07-01
In 2016, the American Academy of Microbiology convened a colloquium to examine point-of-care (POC) microbiology testing and to evaluate its effects on clinical microbiology. Colloquium participants included representatives from clinical microbiology laboratories, industry, and the government, who together made recommendations regarding the implementation, oversight, and evaluation of POC microbiology testing. The colloquium report is timely and well written (V. Dolen et al., Changing Diagnostic Paradigms for Microbiology , 2017, https://www.asm.org/index.php/colloquium-reports/item/6421-changing-diagnostic-paradigms-for-microbiology?utm_source=Commentary&utm_medium=referral&utm_campaign=diagnostics). Emerging POC microbiology tests, especially nucleic acid amplification tests, have the potential to advance medical care. Copyright © 2017 American Society for Microbiology.
Advances Afoot in Microbiology
Karon, Brad S.
2017-01-01
ABSTRACT In 2016, the American Academy of Microbiology convened a colloquium to examine point-of-care (POC) microbiology testing and to evaluate its effects on clinical microbiology. Colloquium participants included representatives from clinical microbiology laboratories, industry, and the government, who together made recommendations regarding the implementation, oversight, and evaluation of POC microbiology testing. The colloquium report is timely and well written (V. Dolen et al., Changing Diagnostic Paradigms for Microbiology, 2017, https://www.asm.org/index.php/colloquium-reports/item/6421-changing-diagnostic-paradigms-for-microbiology?utm_source=Commentary&utm_medium=referral&utm_campaign=diagnostics). Emerging POC microbiology tests, especially nucleic acid amplification tests, have the potential to advance medical care. PMID:28539341
Natoli, Lisa; Guy, Rebecca J.; Shephard, Mark; Causer, Louise; Badman, Steven G.; Hengel, Belinda; Tangey, Annie; Ward, James; Coburn, Tony; Anderson, David; Kaldor, John; Maher, Lisa
2015-01-01
Background Point-of-care tests for chlamydia (CT) and gonorrhoea (NG) could increase the uptake and timeliness of testing and treatment, contribute to improved disease control and reduce reproductive morbidity. The GeneXpert (Xpert CT/NG assay), suited to use at the point-of-care, is being used in the TTANGO randomised controlled trial (RCT) in 12 remote Australian health services with a high burden of sexually transmissible infections (STIs). This represents the first ever routine use of a molecular point-of-care diagnostic for STIs in primary care. The purpose of this study was to explore the acceptability of the GeneXpert to primary care staff in remote Australia. Methods In-depth qualitative interviews were conducted with 16 staff (registered or enrolled nurses and Aboriginal Health Workers/Practitioners) trained and experienced with GeneXpert testing. Interviews were digitally-recorded and transcribed verbatim prior to content analysis. Results Most participants displayed positive attitudes, indicating the test was both easy to use and useful in their clinical context. Participants indicated that point-of-care testing had improved management of STIs, resulting in more timely and targeted treatment, earlier commencement of partner notification, and reduced follow up efforts associated with client recall. Staff expressed confidence in point-of-care test results and treating patients on this basis, and reported greater job satisfaction. While point-of-care testing did not negatively impact on client flow, several found the manual documentation processes time consuming, suggesting that improved electronic connectivity and test result transfer between the GeneXpert and patient management systems could overcome this. Managing positive test results in a shorter time frame was challenging for some but most found it satisfying to complete episodes of care more quickly. Conclusions In the context of a RCT, health professionals working in remote primary care in Australia
Herbert, R; Ashraf, A N; Yates, T A; Spriggs, K; Malinnag, M; Durward-Brown, E; Phillips, D; Mewse, E; Daniel, A; Armstrong, M; Kidd, I M; Waite, J; Wilks, P; Burns, F; Bailey, R; Brown, M
2012-09-01
Early diagnosis of HIV infection reduces morbidity and mortality associated with late presentation. Despite UK guidelines, the HIV testing rate has not increased. We have introduced universal HIV screening in an open-access returning traveller clinic. Data were prospectively recorded for all patients attending the open-access returning traveller clinic between August 2008 and December 2010. HIV testing was offered to all patients from May 2009; initially testing with laboratory samples (phase 1) and subsequently a point-of-care test (POCT) (phase 2). A total of 4965 patients attended the clinic; 1342 in phase 0, 792 in phase 1 and 2831 in phase 2. Testing rates for HIV increased significantly from 2% (38 of 1342) in phase 0 to 23.1% (183 of 792) in phase 1 and further increased to 44.5% (1261 of 2831) during phase 2 (P < 0.0001). Two new diagnoses of HIV-1 were identified in phase 1 (1.1% of tested); seven patients had a reactive POCT test in phase 2, of whom five (0.4% of those tested) were confirmed in a 4th generation assay. The patients with false reactive tests had a concurrent Plasmodium falciparum infection. Patients travelling to the Middle East and Europe were less likely to accept an HIV test with POCT. A nurse-delivered universal point-of-care HIV testing service has been successfully introduced and sustained in an acute medical clinic in a low-prevalence country. Caution is required in communicating reactive results in low-prevalence settings where there may be alternative diagnoses or a low population prevalence of HIV infection. © 2012 British HIV Association.
Cost analysis of a novel HIV testing strategy in community pharmacies and retail clinics.
Lecher, Shirley Lee; Shrestha, Ram K; Botts, Linda W; Alvarez, Jorge; Moore, James H; Thomas, Vasavi; Weidle, Paul J
2015-01-01
To document the cost of implementing point-of-care (POC) human immunodeficiency virus (HIV) rapid testing in busy community pharmacies and retail clinics. Providing HIV testing services in community pharmacies and retail clinics is an innovative way to expand HIV testing. The cost of implementing POC HIV rapid testing in a busy retail environment needs to be documented to provide program and policy leaders with adequate information for planning and budgeting. Cost analysis from a pilot project that provided confidential POC HIV rapid testing services in community pharmacies and retail clinics. The pharmacy sites were operated under several different ownership structures (for-profit, nonprofit, sole proprietorship, corporation, public, and private) in urban and rural areas. We included data from the initial six sites that participated in the project. We collected the time spent by pharmacy and retail clinic staff for pretest and posttest counseling in an activity log for time-in-motion for each interaction. Pharmacists and retail clinic staff. HIV rapid testing. The total cost was calculated to include costs of test kits, control kits, shipping, test supplies, training, reporting, program administration, and advertising. The six sites trained 22 staff to implement HIV testing. A total of 939 HIV rapid tests were conducted over a median time of 12 months, of which 17 were reactive. Median pretest counseling time was 2 minutes. Median posttest counseling time was 2 minutes for clients with a nonreactive test and 10 minutes for clients with a reactive test. The average cost per person tested was an estimated $47.21. When we considered only recurrent costs, the average cost per person tested was $32.17. Providing POC HIV rapid testing services required a modest amount of staff time and costs that are comparable to other services offered in these settings. HIV testing in pharmacies and retail clinics can provide an additional alternative venue for increasing the
Levy, J K; Crawford, P Cynda; Tucker, S J
2017-03-01
More than 3 million cats in the United States are infected with FeLV or FIV. The cornerstone of control is identification and segregation of infected cats. To compare test performance with well-characterized clinical samples of currently available FeLV antigen/FIV antibody combination test kits. Surplus serum and plasma from diagnostic samples submitted by animal shelters, diagnostic laboratories, veterinary clinics, and cat research colonies. None of the cats had been vaccinated against FIV. The final sample set included 146 FeLV+, 154 FeLV-, 94 FIV+, and 97 FIV- samples. Prospective, blind comparison to a gold standard: Samples were evaluated in 4 different point-of-care tests by ELISA antigen plate tests (FeLV) and virus isolation (FIV) as the reference standards. All test results were visually read by 2 blinded observers. Sensitivity and specificity, respectively, for FeLV were SNAP ® (100%/100%), WITNESS ® (89.0%/95.5%), Anigen ® (91.8%/95.5%), and VetScan ® (85.6%/85.7%). Sensitivity and specificity for FIV were SNAP ® (97.9%/99.0%), WITNESS ® (94.7%/100%), Anigen ® (96.8%/99.0%), and VetScan ® (91.5%/99.0%). The SNAP ® test had the best performance for FeLV, but there were no significant differences for FIV. In typical cat populations with seroprevalence of 1-5%, a majority of positive results reported by most point-of-care test devices would be false-positives. This could result in unnecessary segregation or even euthanasia. Copyright © 2017 The Authors. Journal of Veterinary Internal Medicine published by Wiley Periodicals, Inc. on behalf of the American College of Veterinary Internal Medicine.
Enhanced POC export in the oligotrophic northwest Pacific Ocean after extreme weather events
NASA Astrophysics Data System (ADS)
Chen, Kuo-Shu; Hung, Chin-Chang; Gong, Gwo-Ching; Chou, Wen-Chen; Chung, Chih-Ching; Shih, Yung-Yen; Wang, Chau-Chang
2013-11-01
study effects of extreme weather events (EWEs, e.g., dust storm and typhoon) on the export of particulate organic carbon (POC) measured by a floating sediment trap in the oligotrophic ocean, eight sea-going expeditions were conducted in the oligotrophic northwest Pacific (NWP) in 2007 and 2008, covering all four seasons and the passage of several EWEs. Results of year-round field observations demonstrate that the POC export fluxes in the oligotrophic NWP did not exhibit apparent seasonal variations yielding an average flux of 36.9 ± 5.8 mg-C m-2 d-1 without EWE effects. With EWE effects, however, the POC export flux (51.7 ± 13.2 mg-C m-2 d-1) showed an approximately 40% increase compared to the average flux measured without EWE effects. These results suggest that EWEs can trigger elevated POC export from the euphotic zone in the oligotrophic ocean.
De Schacht, Caroline; Lucas, Carlota; Sitoe, Nádia; Machekano, Rhoderick; Chongo, Patrina; Temmerman, Marleen; Tobaiwa, Ocean; Guay, Laura; Kassaye, Seble; Jani, Ilesh V
2015-01-01
Anemia, syphilis and HIV are high burden diseases among pregnant women in sub-Saharan Africa. A quasi-experimental study was conducted in four health facilities in Southern Mozambique to evaluate the effect of point-of-care technologies for hemoglobin quantification, syphilis testing and CD4+ T-cell enumeration performed within maternal and child health services on testing and treatment coverage, and assessing acceptability by health workers. Demographic and testing data on women attending first antenatal care services were extracted from existing records, before (2011; n = 865) and after (2012; n = 808) introduction of point-of-care testing. Study outcomes per health facility were compared using z-tests (categorical variables) and Wilcoxon rank-sum test (continuous variables), while inverse variance weights were used to adjust for possible cluster effects in the pooled analysis. A structured acceptability-assessment interview was conducted with health workers before (n = 22) and after (n = 19). After implementation of point-of-care testing, there was no significant change in uptake of overall hemoglobin screening (67.9% to 83.0%; p = 0.229), syphilis screening (80.8% to 87.0%; p = 0.282) and CD4+ T-cell testing (84.9% to 83.5%; p = 0.930). Initiation of antiretroviral therapy for treatment eligible women was similar in the weighted analysis before and after, with variability among the sites. Time from HIV diagnosis to treatment initiation decreased (median of 44 days to 17 days; p<0.0001). A generally good acceptability for point-of-care testing was seen among health workers. Point-of-care CD4+ T-cell enumeration resulted in a decreased time to initiation of antiretroviral therapy among treatment eligible women, without significant increase in testing coverage. Overall hemoglobin and syphilis screening increased. Despite the perception that point-of-care technologies increase access to health services, the variability in results indicate the potential for
Harper, Lane; Powell, Jeff; Pijl, Em M
2017-07-31
Given the current opioid crisis around the world, harm reduction agencies are seeking to help people who use drugs to do so more safely. Many harm reduction agencies are exploring techniques to test illicit drugs to identify and, where possible, quantify their constituents allowing their users to make informed decisions. While these technologies have been used for years in Europe (Nightlife Empowerment & Well-being Implementation Project, Drug Checking Service: Good Practice Standards; Trans European Drugs Information (TEDI) Workgroup, Factsheet on Drug Checking in Europe, 2011; European Monitoring Centre for Drugs and Drug Addiction, An Inventory of On-site Pill-Testing Interventions in the EU: Fact Files, 2001), they are only now starting to be utilized in this context in North America. The goal of this paper is to describe the most common methods for testing illicit substances and then, based on this broad, encompassing review, recommend the most appropriate methods for testing at point of care.Based on our review, the best methods for point-of-care drug testing are handheld infrared spectroscopy, Raman spectroscopy, and ion mobility spectrometry; mass spectrometry is the current gold standard in forensic drug analysis. It would be prudent for agencies or clinics that can obtain the funding to contact the companies who produce these devices to discuss possible usage in a harm reduction setting. Lower tech options, such as spot/color tests and immunoassays, are limited in their use but affordable and easy to use.
Shephard, Mark D; Mazzachi, Beryl C; Watkinson, Les; Shephard, Anne K; Laurence, Caroline; Gialamas, Angela; Bubner, Tanya
2009-01-01
From September 2005 to February 2007 the Australian Government funded the Point of Care Testing (PoCT) in General Practice Trial, a multi-centre, cluster randomised controlled trial to determine the safety, clinical effectiveness, cost-effectiveness and satisfaction of PoCT in General Practice. In total, 53 practices (23 control and 30 intervention) based in urban, rural or remote locations across three states (South Australia [SA], New South Wales [NSW] and Victoria [VIC]) participated in the Trial. Control practices had pathology testing performed by their local laboratory, while intervention practices conducted pathology testing by PoCT. In total, 4968 patients (1958 control and 3010 intervention) participated in the Trial. The point-of-care (PoC) tests performed by intervention practices were: haemoglobin A1c (HbA1c) and urine albumin:creatinine ratio (ACR) on patients with diabetes, total cholesterol, triglyceride and high density lipoprotein (HDL) cholesterol on patients with hyperlipidaemia, and international normalised ratio (INR) on patients on anticoagulant therapy. Three PoCT devices measured these tests: the Siemens DCA 2000 (Siemens HealthCare Diagnostics, Melbourne, VIC, Australia) for HbA1c and urine ACR; Point of Care Diagnostics Cholestech LDX analyser (Point of Care Diagnostics; Sydney, NSW, Australia) for lipids; and the Roche CoaguChek S (Roche Diagnostics; Sydney, NSW, Australia) for INR. Point-of-care testing in the General Practice Trial was underpinned by a quality management framework which included an on-going training and competency program for PoCT device operators. This article describes the design, implementation and results of the training and competency program. An education and training resource package was developed for the Trial consisting of a training manual, a set of A3 laminated posters and a CD ROM. Five initial training workshops were held for intervention practices from each geographic region between August and October 2005
Gao, Li; Li, Cuidi; Chen, Fangping; Liu, Changsheng
2015-06-24
A novel elastomeric material, poly(1,8-octanediol-co-citrate) (POC), has demonstrated tremendous versatility because of its advantageous toughness, tunable degradation properties, and efficient drug release capability. In this study, POC was used to improve the mechanical performance of β-tricalcium phosphate (β-Ca3(PO4)2, β-TCP). (3D) β-TCP/POC composite scaffolds were fabricated by a 3D printing technique based on the freeform fabrication system with micro-droplet jetting (FFS-MDJ). The physiochemical properties, compressive modulus, drug release behavior, and cell response of β-TCP/POC composite scaffolds were systematically investigated. The results showed that β-TCP/POC scaffolds had uniform macropores of 300-400 μm, porosity of approximately 45%, biodegradability in phosphate-buffered saline, and high compressive modulus of 50-75 MPa. With the incorporation of POC into β-TCP, the toughness of the composite scaffolds was improved significantly. Moreover, β-TCP/POC scaffolds exhibited sustained drug (ibuprofen (IBU)) release capability. Additionally, β-TCP/POC scaffolds facilitated C2C12 cell attachment and proliferation. It was indicated that the 3D-printed porous β-TCP/POC scaffolds with high compressive modulus and good drug delivery performance might be a promising candidate for bone defect repair.
Laser-induced fluorescence detection platform for point-of-care testing
NASA Astrophysics Data System (ADS)
Berner, Marcel; Hilbig, Urs; Schubert, Markus B.; Gauglitz, Günter
2017-08-01
Point-of-care testing (POCT) devices for continuous low-cost monitoring of critical patient parameters require miniaturized and integrated setups for performing quick high-sensitivity analyses, away from central clinical laboratories. This work presents a novel and promising laser-induced fluorescence platform for measurements in direct optical test formats that leads towards such powerful POCT devices based on fluorescence-labeled immunoassays. Ultimate sensitivity of thin film photodetectors, integrated with microfluidics, and a comprehensive optimization of all system components aim at low-level signal detection in the targeted biosensor application. The setup acquires fluorescence signals from the volume of a microfluidic channel. An innovative sandwiching process forms a flow channel in the microfluidic chips by embedding laser-cut double-sided adhesive tapes. The custom fit of amorphous silicon based photodiode arrays to the geometry of the flow channel enables miniaturization, fully adequate for POCT devices. A free-beam laser excitation with line focus provides excellent alignment stability, allows for easy and reliable swapping of the disposable microfluidic chips, and therewith greatly improves the ease of use of the resulting integrated device. As a proof-of-concept of this novel in-volume measurement approach, the limit of detection for the dye DY636-COOH in pure water as a model fluorophore is examined and found to be 26 nmol l-1 .
Advances in paper-based sample pretreatment for point-of-care testing.
Tang, Rui Hua; Yang, Hui; Choi, Jane Ru; Gong, Yan; Feng, Shang Sheng; Pingguan-Murphy, Belinda; Huang, Qing Sheng; Shi, Jun Ling; Mei, Qi Bing; Xu, Feng
2017-06-01
In recent years, paper-based point-of-care testing (POCT) has been widely used in medical diagnostics, food safety and environmental monitoring. However, a high-cost, time-consuming and equipment-dependent sample pretreatment technique is generally required for raw sample processing, which are impractical for low-resource and disease-endemic areas. Therefore, there is an escalating demand for a cost-effective, simple and portable pretreatment technique, to be coupled with the commonly used paper-based assay (e.g. lateral flow assay) in POCT. In this review, we focus on the importance of using paper as a platform for sample pretreatment. We firstly discuss the beneficial use of paper for sample pretreatment, including sample collection and storage, separation, extraction, and concentration. We highlight the working principle and fabrication of each sample pretreatment device, the existing challenges and the future perspectives for developing paper-based sample pretreatment technique.
Tetrahymena Poc1 ensures proper intertriplet microtubule linkages to maintain basal body integrity
Meehl, Janet B.; Bayless, Brian A.; Giddings, Thomas H.; Pearson, Chad G.; Winey, Mark
2016-01-01
Basal bodies comprise nine symmetric triplet microtubules that anchor forces produced by the asymmetric beat pattern of motile cilia. The ciliopathy protein Poc1 stabilizes basal bodies through an unknown mechanism. In poc1∆ cells, electron tomography reveals subtle defects in the organization of intertriplet linkers (A-C linkers) that connect adjacent triplet microtubules. Complete triplet microtubules are lost preferentially near the posterior face of the basal body. Basal bodies that are missing triplets likely remain competent to assemble new basal bodies with nine triplet microtubules, suggesting that the mother basal body microtubule structure does not template the daughter. Our data indicate that Poc1 stabilizes basal body triplet microtubules through linkers between neighboring triplets. Without this stabilization, specific triplet microtubules within the basal body are more susceptible to loss, probably due to force distribution within the basal body during ciliary beating. This work provides insights into how the ciliopathy protein Poc1 maintains basal body integrity. PMID:27251062
Gaydos, Charlotte A; Solis, Melissa; Hsieh, Yu-Hsiang; Jett-Goheen, Mary; Nour, Samah; Rothman, Richard E
2013-09-01
Despite successes in efforts to integrate HIV testing into routine care in emergency departments, challenges remain. Kiosk-facilitated, directed HIV self-testing offers one novel approach to address logistical challenges. Emergency department patients, 18-64 years, were recruited to evaluate use of tablet-based-kiosks to guide patients to conduct their own point-of-care HIV tests followed by standard-of-care HIV tests by healthcare workers. Both tests were OraQuick Advance tests. Of 955 patients approached, 473 (49.5%) consented; 467 completed the test, and 100% had concordant results with healthcare workers. Median age was 41 years, 59.6% were female, 74.8% were African-American, and 19.6% were White. In all, 99.8% of patients believed the self-test was "definitely" or "probably" correct; 91.7% of patients "trusted their results very much"; 99.8% reported "overall" self-testing was "easy or somewhat easy" to perform. Further, 96.9% indicated they would "probably" or "definitely" test themselves at home were the HIV test available for purchase; 25.9% preferred self-testing versus 34.4% who preferred healthcare professional testing (p>0.05). Tablet-based kiosk testing proved to be highly feasible, acceptable, and an accurate method of conducting rapid HIV self-testing in this study; however, rates of engagement were moderate. More research will be required to ascertain barriers to increased engagement for self-testing.
Cost consequences of point-of-care troponin T testing in a Swedish primary health care setting
Andersson, Agneta; Janzon, Magnus; Karlsson, Jan-Erik; Levin, Lars-Åke
2014-01-01
Abstract Objective. To evaluate the safety and cost-effectiveness of point-of-care troponin T testing (POCT-TnT) for the management of patients with chest pain in primary care. Design. Prospective observational study with follow-up. Setting. Three primary health care (PHC) centres using POCT-TnT and four PHC centres not using POCT-TnT in south-east Sweden. Patients. All patients ≥ 35 years of age, contacting one of the PHC centres for chest pain, dyspnoea on exertion, unexplained weakness and/or fatigue, with no other probable cause than cardiac, were included. Symptoms must have commenced or worsened during the previous seven days. Main outcome measures. Emergency referral rates, diagnoses of acute myocardial infarction (AMI) or unstable angina (UA), and costs were collected for 30 days after the patient sought care at the PHC centre. Results. A total of 196 patients with chest pain were included: 128 in PHC centres with POCT-TnT and 68 in PHC centres without POCT-TnT. Fewer patients from the PHC centres with POCT-TnT (n = 32, 25%) were emergently referred to hospital than from centres without POCT-TnT (n = 29, 43%; p = 0.011). Eight patients (6.2%) from PHC centres with POCT-TnT were diagnosed with AMI or UA compared with six patients (8.8%) from centres without POCT-TnT (p = 0.565). Two patients with AMI or UA were classified as missed cases from PHC centres with POCT-TnT and there were no missed cases from PHC centres without POCT-TnT. SKr290 000 was saved per missed case of AMI or UA. Conclusion. The use of POCT-TnT in primary care may be cost saving but at the expense of missed cases. PMID:25434410
Guest, Francesca L; Guest, Paul C
2017-01-01
This chapter describes how innovations that are driven by proteomic biomarker techniques can facilitate earlier and better treatment of patients who suffer from psychiatric disorders. The application of new micro-fluidic devices along with miniaturized biosensors and transducers will enable the development of handheld point-of-care testing instruments which can analyse a drop of a blood within the time span of a single visit to the doctor's office. It is anticipated that these approaches will incorporate both biochemical and clinical information, resulting in unique profiles for each test subject. These profiles can in turn be used to drive personalized medicine approaches in this devastating disease area. In addition, smartphone applications (apps) for self-monitoring will see increasing use for improved patient outcomes.
Naing, Soe; Clouse, Emily; Thu, Kaung Htet; Mon, Sandra Hsu Hnin; Tun, Zin Min; Baral, Stefan; Paing, Aung Zayar; Beyrer, Chris
2017-01-01
Background Efforts to improve HIV diagnosis and antiretroviral therapy (ART) initiation among people living with HIV and reduce onward transmission of HIV rely on innovative interventions along multiple steps of the HIV care continuum. These innovative methods are particularly important for key populations, including men who have sex with men (MSM) and transgender women (TW). The HIV epidemic in Myanmar is concentrated among key populations, and national efforts now focus on reducing stigma and improving engagement of MSM and TW in HIV prevention and care. Objective This study aims to test the use of several innovations to address losses in the HIV care continuum: (1) use of respondent-driven sampling (RDS) to reach and engage MSM and TW in HIV testing, (2) HIV self-testing (HIVST) to increase HIV testing uptake and aid early diagnosis of infection, (3) community-based CD4 point-of-care (POC) technology to rapidly stage HIV disease for those who are HIV infected, and (4) peer navigation support to increase successful health system navigation for HIV-infected MSM and TW in need of ART or HIV engagement in care. Methods To assess the effect of HIVST, we will implement a randomized trial in which MSM and TW adults in the greater Yangon metropolitan area who are HIV uninfected will be recruited via RDS (N=366). Participants will complete a baseline socio-behavioral survey and will be randomized to standard, voluntary counseling and testing (VCT) or to HIVST. Biologic specimens will be collected during this baseline visit for confirmatory testing using dried blood spots. Participants will be asked to return to the study office to complete a second study visit in which they will report their HIV test result and answer questions on the acceptability of the assigned testing method. Aim 1 participants with confirmed HIV infection and who are not engaged in care (N=49) will be offered direct enrollment into Aims 2 and 3, which include immediate CD4 POC and the option for
Saulnier, George E; Castro, Janna C; Cook, Curtiss B
2014-05-01
Glucose control can be problematic in critically ill patients. We evaluated the impact of statistical transformation on interpretation of intensive care unit inpatient glucose control data. Point-of-care blood glucose (POC-BG) data derived from patients in the intensive care unit for 2011 was obtained. Box-Cox transformation of POC-BG measurements was performed, and distribution of data was determined before and after transformation. Different data subsets were used to establish statistical upper and lower control limits. Exponentially weighted moving average (EWMA) control charts constructed from April, October, and November data determined whether out-of-control events could be identified differently in transformed versus nontransformed data. A total of 8679 POC-BG values were analyzed. POC-BG distributions in nontransformed data were skewed but approached normality after transformation. EWMA control charts revealed differences in projected detection of out-of-control events. In April, an out-of-control process resulting in the lower control limit being exceeded was identified at sample 116 in nontransformed data but not in transformed data. October transformed data detected an out-of-control process exceeding the upper control limit at sample 27 that was not detected in nontransformed data. Nontransformed November results remained in control, but transformation identified an out-of-control event less than 10 samples into the observation period. Using statistical methods to assess population-based glucose control in the intensive care unit could alter conclusions about the effectiveness of care processes for managing hyperglycemia. Further study is required to determine whether transformed versus nontransformed data change clinical decisions about the interpretation of care or intervention results. © 2014 Diabetes Technology Society.
Saulnier, George E.; Castro, Janna C.
2014-01-01
Glucose control can be problematic in critically ill patients. We evaluated the impact of statistical transformation on interpretation of intensive care unit inpatient glucose control data. Point-of-care blood glucose (POC-BG) data derived from patients in the intensive care unit for 2011 was obtained. Box–Cox transformation of POC-BG measurements was performed, and distribution of data was determined before and after transformation. Different data subsets were used to establish statistical upper and lower control limits. Exponentially weighted moving average (EWMA) control charts constructed from April, October, and November data determined whether out-of-control events could be identified differently in transformed versus nontransformed data. A total of 8679 POC-BG values were analyzed. POC-BG distributions in nontransformed data were skewed but approached normality after transformation. EWMA control charts revealed differences in projected detection of out-of-control events. In April, an out-of-control process resulting in the lower control limit being exceeded was identified at sample 116 in nontransformed data but not in transformed data. October transformed data detected an out-of-control process exceeding the upper control limit at sample 27 that was not detected in nontransformed data. Nontransformed November results remained in control, but transformation identified an out-of-control event less than 10 samples into the observation period. Using statistical methods to assess population-based glucose control in the intensive care unit could alter conclusions about the effectiveness of care processes for managing hyperglycemia. Further study is required to determine whether transformed versus nontransformed data change clinical decisions about the interpretation of care or intervention results. PMID:24876620
Reducing patient identification errors related to glucose point-of-care testing.
Alreja, Gaurav; Setia, Namrata; Nichols, James; Pantanowitz, Liron
2011-01-01
Patient identification (ID) errors in point-of-care testing (POCT) can cause test results to be transferred to the wrong patient's chart or prevent results from being transmitted and reported. Despite the implementation of patient barcoding and ongoing operator training at our institution, patient ID errors still occur with glucose POCT. The aim of this study was to develop a solution to reduce identification errors with POCT. Glucose POCT was performed by approximately 2,400 clinical operators throughout our health system. Patients are identified by scanning in wristband barcodes or by manual data entry using portable glucose meters. Meters are docked to upload data to a database server which then transmits data to any medical record matching the financial number of the test result. With a new model, meters connect to an interface manager where the patient ID (a nine-digit account number) is checked against patient registration data from admission, discharge, and transfer (ADT) feeds and only matched results are transferred to the patient's electronic medical record. With the new process, the patient ID is checked prior to testing, and testing is prevented until ID errors are resolved. When averaged over a period of a month, ID errors were reduced to 3 errors/month (0.015%) in comparison with 61.5 errors/month (0.319%) before implementing the new meters. Patient ID errors may occur with glucose POCT despite patient barcoding. The verification of patient identification should ideally take place at the bedside before testing occurs so that the errors can be addressed in real time. The introduction of an ADT feed directly to glucose meters reduced patient ID errors in POCT.
Distance-based microfluidic quantitative detection methods for point-of-care testing.
Tian, Tian; Li, Jiuxing; Song, Yanling; Zhou, Leiji; Zhu, Zhi; Yang, Chaoyong James
2016-04-07
Equipment-free devices with quantitative readout are of great significance to point-of-care testing (POCT), which provides real-time readout to users and is especially important in low-resource settings. Among various equipment-free approaches, distance-based visual quantitative detection methods rely on reading the visual signal length for corresponding target concentrations, thus eliminating the need for sophisticated instruments. The distance-based methods are low-cost, user-friendly and can be integrated into portable analytical devices. Moreover, such methods enable quantitative detection of various targets by the naked eye. In this review, we first introduce the concept and history of distance-based visual quantitative detection methods. Then, we summarize the main methods for translation of molecular signals to distance-based readout and discuss different microfluidic platforms (glass, PDMS, paper and thread) in terms of applications in biomedical diagnostics, food safety monitoring, and environmental analysis. Finally, the potential and future perspectives are discussed.
Lenters-Westra, Erna; Strunk, Annuska; Campbell, Paul; Slingerland, Robbert J
2017-02-01
Hb-variant interference when reporting HbA1c has been an ongoing challenge since HbA1c was introduced to monitor patients with diabetes mellitus. Most Hb-variants show an abnormal chromatogram when cation-exchange HPLC is used for the determination of HbA1c. Unfortunately, the Tosoh G8 generates what appears to be normal chromatogram in the presence of Hb-Tacoma, yielding a falsely high HbA1c value. The primary aim of the study was to investigate if the Afinion HbA1c point-of-care (POC) instrument could be used as an alternative method for the Tosoh G8 when testing for HbA1c in the presence of Hb-Tacoma. Whole blood samples were collected in K 2 EDTA tubes from individuals homozygous for HbA (n = 40) and heterozygous for Hb-Tacoma (n = 20). Samples were then immediately analyzed with the Afinion POC instrument. After analysis, aliquots of each sample were frozen at -80 °C. The frozen samples were shipped on dry ice to the European Reference Laboratory for Glycohemoglobin (ERL) and analyzed with three International Federation of Clinical Chemistry and Laboratory Medicine (IFCC) and National Glycohemoglobin Standardization Program (NGSP) Secondary Reference Measurement Procedures (SRMPs). The Premier Hb9210 was used as the reference method. When compared to the reference method, samples with Hb-Tacoma yielded mean relative differences of 31.8% on the Tosoh G8, 21.5% on the Roche Tina-quant Gen. 2 and 16.8% on the Afinion. The Afinion cannot be used as an alternative method for the Tosoh G8 when testing for HbA1c in the presence of Hb-Tacoma.
Kim, Saorin; Nhem, Sina; Dourng, Dany; Ménard, Didier
2015-03-14
Malaria rapid diagnostic tests (RDTs) are generally considered as point-of-care tests. However, most of the studies assessing the performance of malaria RDTs are conducted by research teams that are not representative of the classical end-users, who are typically unskilled in traditional laboratory techniques for diagnosing malaria. To evaluate the performance of a malaria RDT by end-users in a malaria-endemic area, a study protocol was designed and the VIKIA Malaria Ag Pf/Pan test, previously evaluated in 2013, was re-evaluated by representative end-users. Twenty end-users with four different profiles in seven communes in Kampot Province (Cambodia) were selected. A set of 20 calibrated aliquots, including negative samples, low positive samples (200 parasites/μL of Plasmodium falciparum and Plasmodium vivax) and high positive samples (2,000 parasites/μL of P. falciparum and P. vivax) was used. Testing was performed directly by the end-users without any practical training on the VIKIA Malaria Ag Pf/Pan kit. All results obtained by the end-users were consistent with the expected results, except for the low positive (200 parasites/μL) P. vivax aliquot (35% of concordant results). No significant difference was observed between the different end-users. End-user interviews evaluating ease-of-use and ease-of-reading of the VIKIA Malaria Ag Pf/Pan kit recorded 159 positive answers and only one negative answer. Out of 20 end-users, only one considered the test was not easy to perform with the support of the quick guide. The data presented in this study clearly demonstrate that the performance of the VIKIA Malaria Ag Pf/Pan test when performed by traditional end-users in field conditions is similar to that obtained by a research team and that this RDT can be considered as a point-of-care tool/assay. Furthermore, the protocol designed for this study could be used systematically in parallel to conventional evaluation studies to determine the performance of malaria RDTs in
NASA Astrophysics Data System (ADS)
Liu, Nathan J.; Chapman, Robert; Lin, Yiyang; Mmesi, Jonas; Bentham, Andrew; Tyreman, Matthew; Abraham, Sonya; Stevens, Molly M.
2016-02-01
Secretory phospholipase A2 group IIA (sPLA2-IIA) was examined as a point of care marker for determining disease activity in rheumatoid (RA) and psoriatic (PsA) arthritis. Serum concentration and activity of sPLA2-IIA were measured using in-house antibodies and a novel point of care lateral flow device assay in patients diagnosed with varying severities of RA (n = 30) and PsA (n = 25) and found to correlate strongly with C-reactive protein (CRP). Levels of all markers were elevated in patients with active RA over those with inactive RA as well as both active and inactive PsA, indicating that sPLA2-IIA can be used as an analogue to CRP for RA diagnosis at point of care.Secretory phospholipase A2 group IIA (sPLA2-IIA) was examined as a point of care marker for determining disease activity in rheumatoid (RA) and psoriatic (PsA) arthritis. Serum concentration and activity of sPLA2-IIA were measured using in-house antibodies and a novel point of care lateral flow device assay in patients diagnosed with varying severities of RA (n = 30) and PsA (n = 25) and found to correlate strongly with C-reactive protein (CRP). Levels of all markers were elevated in patients with active RA over those with inactive RA as well as both active and inactive PsA, indicating that sPLA2-IIA can be used as an analogue to CRP for RA diagnosis at point of care. Electronic supplementary information (ESI) available. See DOI: 10.1039/c5nr08423g
Reducing patient identification errors related to glucose point-of-care testing
Alreja, Gaurav; Setia, Namrata; Nichols, James; Pantanowitz, Liron
2011-01-01
Background: Patient identification (ID) errors in point-of-care testing (POCT) can cause test results to be transferred to the wrong patient's chart or prevent results from being transmitted and reported. Despite the implementation of patient barcoding and ongoing operator training at our institution, patient ID errors still occur with glucose POCT. The aim of this study was to develop a solution to reduce identification errors with POCT. Materials and Methods: Glucose POCT was performed by approximately 2,400 clinical operators throughout our health system. Patients are identified by scanning in wristband barcodes or by manual data entry using portable glucose meters. Meters are docked to upload data to a database server which then transmits data to any medical record matching the financial number of the test result. With a new model, meters connect to an interface manager where the patient ID (a nine-digit account number) is checked against patient registration data from admission, discharge, and transfer (ADT) feeds and only matched results are transferred to the patient's electronic medical record. With the new process, the patient ID is checked prior to testing, and testing is prevented until ID errors are resolved. Results: When averaged over a period of a month, ID errors were reduced to 3 errors/month (0.015%) in comparison with 61.5 errors/month (0.319%) before implementing the new meters. Conclusion: Patient ID errors may occur with glucose POCT despite patient barcoding. The verification of patient identification should ideally take place at the bedside before testing occurs so that the errors can be addressed in real time. The introduction of an ADT feed directly to glucose meters reduced patient ID errors in POCT. PMID:21633490
Stawicki, Stanislaw P; Stoltzfus, Jill C; Aggarwal, Praveen; Bhoi, Sanjeev; Bhatt, Shashi; Kalra, O P; Bhalla, Ashish; Hoey, Brian A; Galwankar, Sagar C; Paladino, Lorenzo; Papadimos, Thomas J
2014-07-01
Biomarker science brings great promise to clinical medicine. This is especially true in the era of technology miniaturization, rapid dissemination of knowledge, and point-of-care (POC) implementation of novel diagnostics. Despite this tremendous progress, the journey from a candidate biomarker to a scientifically validated biomarker continues to be an arduous one. In addition to substantial financial resources, biomarker research requires considerable expertise and a multidisciplinary approach. Investigational designs must also be taken into account, with the randomized controlled trial remaining the "gold standard". The authors present a condensed overview of biomarker science and associated investigational methods, followed by specific examples from clinical areas where biomarker development and/or implementation resulted in tangible enhancements in patient care. This manuscript also serves as a call to arms for the establishment of a truly global, well-coordinated infrastructure dedicated to biomarker research and development, with focus on delivery of the latest discoveries directly to the patient via point-of-care technology.
Recent Progress in the Development of Diagnostic Tests for Malaria.
Krampa, Francis D; Aniweh, Yaw; Awandare, Gordon A; Kanyong, Prosper
2017-09-19
The impact of malaria on global health has continually prompted the need to develop effective diagnostic strategies. In malaria endemic regions, routine diagnosis is hampered by technical and infrastructural challenges to laboratories. These laboratories lack standard facilities, expertise or diagnostic supplies; thus, therapy is administered based on clinical or self-diagnosis. There is the need for accurate diagnosis of malaria due to the continuous increase in the cost of medication, and the emergence and spread of drug resistant strains. However, the widely utilized Giemsa-stained microscopy and immunochromatographic tests for malaria are liable to several drawbacks, including inadequate sensitivity and false-positive outcomes. Alternative methods that offer improvements in performance are either expensive, have longer turnaround time or require a level of expertise that makes them unsuitable for point-of-care (POC) applications. These gaps necessitate exploration of more efficient detection techniques with the potential of POC applications, especially in resource-limited settings. This minireview discusses some of the recent trends and new approaches that are seeking to improve the clinical diagnosis of malaria.
Surface enhanced Raman spectroscopy based nanoparticle assays for rapid, point-of-care diagnostics
NASA Astrophysics Data System (ADS)
Driscoll, Ashley J.
Nucleotide and immunoassays are important tools for disease diagnostics. Many of the current laboratory-based analytical diagnostic techniques require multiple assay steps and long incubation times before results are acquired. In the development of bioassays designed for detecting the emergence and spread of diseases in point-of-care (POC) and remote settings, more rapid and portable analytical methods are necessary. Nanoparticles provide simple and reproducible synthetic methods for the preparation of substrates that can be applied in colloidal assays, providing gains in kinetics due to miniaturization and plasmonic substrates for surface enhanced spectroscopies. Specifically, surface enhanced Raman spectroscopy (SERS) is finding broad application as a signal transduction method in immunological and nucleotide assays due to the production of narrow spectral peaks from the scattering molecules and the potential for simultaneous multiple analyte detection. The application of SERS to a no-wash, magnetic capture assay for the detection of West Nile Virus Envelope and Rift Valley Fever Virus N antigens is described. The platform utilizes colloid based capture of the target antigen in solution, magnetic collection of the immunocomplexes and acquisition of SERS spectra by a handheld Raman spectrometer. The reagents for a core-shell nanoparticle, SERS based assay designed for the capture of target microRNA implicated in acute myocardial infarction are also characterized. Several new, small molecule Raman scatterers are introduced and used to analyze the enhancing properties of the synthesized gold coated-magnetic nanoparticles. Nucleotide and immunoassay platforms have shown improvements in speed and analyte capture through the miniaturization of the capture surface and particle-based capture systems can provide a route to further surface miniaturization. A reaction-diffusion model of the colloidal assay platform is presented to understand the interplay of system
A point-of-care chemistry test for reduction of turnaround and clinical decision time.
Lee, Eui Jung; Shin, Sang Do; Song, Kyoung Jun; Kim, Seong Chun; Cho, Jin Seong; Lee, Seung Chul; Park, Ju Ok; Cha, Won Chul
2011-06-01
Our study compared clinical decision time between patients managed with a point-of-care chemistry test (POCT) and patients managed with the traditional central laboratory test (CLT). This was a randomized controlled multicenter trial in the emergency departments (EDs) of 5 academic teaching hospitals. We randomly assigned patients to POCT or CLT stratified by the Emergency Severity Index. A POCT chemistry analyzer (Piccolo; Abaxis, Inc, Union City, Calif), which is able to test liver panel, renal panel, pancreas enzymes, lipid panel, electrolytes, and blood gases, was set up in each ED. Primary and secondary end point was turnaround time and door-to-clinical-decision time. The total 2323 patients were randomly assigned to the POCT group (n = 1167) or to the CLT group (n = 1156). All of the basic characteristics were similar in the 2 groups. The turnaround time (median, interquartile range [IQR]) of the POCT group was shorter than that of the CLT group (14, 12-19 versus 55, 45-69 minutes; P < .0001). The median (IQR) door-to-clinical-decision time was also shorter in the POCT compared with the CLT group (46, 33-61 versus 86, 68-107 minutes; P < .0001). The proportion of patients who had new decisions within 60 minutes was 72.8% for the POCT group and 12.5% for the CLT group (P < .0001). A POCT chemistry analyzer in the ED shortens the test turnaround and ED clinical decision times compared with CLT. Copyright © 2011 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Devadhasan, Jasmine P.; Kim, Sanghyo
2015-07-01
Complementary metal oxide semiconductor (CMOS) image sensors are received great attention for their high efficiency in biological applications. The present work describes a CMOS image sensor-based whole blood glucose monitoring system through a point-of-care (POC) approach. A simple poly-ethylene terephthalate (PET) film chip was developed to carry out the enzyme kinetic reaction at various concentrations of blood glucose. In this technique, assay reagent was adsorbed onto amine functionalized silica (AFSiO2) nanoparticles in order to achieve glucose oxidation on the PET film chip. The AFSiO2 nanoparticles can immobilize the assay reagent with an electrostatic attraction and eased to develop the opaque platform which was technically suitable chip to analyze by the camera module. The oxidized glucose then produces a green color according to the glucose concentration and is analyzed by the camera module as a photon detection technique. The photon number decreases with increasing glucose concentration. The simple sensing approach, utilizing enzyme immobilized AFSiO2 nanoparticle chip and assay detection method was developed for quantitative glucose measurement.
2014-01-01
Background Globally, no qualitative studies have explored the perspectives of women and their partners about the integration of technology – and specifically diagnostic testing technologies – into antenatal care. The study objective was to describe the demand side for pregnancy-related diagnostic tests from the perspective of Peruvian consumers, including female and male community members, by engaging participants about their awareness of and care-seeking for pregnancy-related diagnostic tests and their preferred characteristics and testing conditions for pregnancy-related point-of-care diagnostic tests (POCTs). Methods Sixty-seven mothers and fathers of children under one from the peri-urban coast and the peri-urban and rural highlands and jungle of Peru participated in ten focus groups. Results Participants think that pregnancy-related diagnostic tests are important and they and their fellow community members are committed to ensuring that pregnant women receive the tests they need. Participants expressed clear demands for pregnancy-related POCTs, including important characteristics for the tests themselves (certification, rapid, reliable results) and for test implementation (well-trained, personable good communicators as test administrators at well-equipped, convenient testing sites). Participants emphasized the importance of short waiting times and explained that many people have some ability to pay for POCTs, particularly if they are innovative, rapid or multiplex. Conclusions Engaging future POCT users as consumers who are able to make key decisions about the development and implementation of pregnancy-related POCTs is valuable and informative. PMID:24433514
POCS-enhanced correction of motion artifacts in parallel MRI.
Samsonov, Alexey A; Velikina, Julia; Jung, Youngkyoo; Kholmovski, Eugene G; Johnson, Chris R; Block, Walter F
2010-04-01
A new method for correction of MRI motion artifacts induced by corrupted k-space data, acquired by multiple receiver coils such as phased arrays, is presented. In our approach, a projections onto convex sets (POCS)-based method for reconstruction of sensitivity encoded MRI data (POCSENSE) is employed to identify corrupted k-space samples. After the erroneous data are discarded from the dataset, the artifact-free images are restored from the remaining data using coil sensitivity profiles. The error detection and data restoration are based on informational redundancy of phased-array data and may be applied to full and reduced datasets. An important advantage of the new POCS-based method is that, in addition to multicoil data redundancy, it can use a priori known properties about the imaged object for improved MR image artifact correction. The use of such information was shown to improve significantly k-space error detection and image artifact correction. The method was validated on data corrupted by simulated and real motion such as head motion and pulsatile flow.
Wang, Fangnian; Tian, Yu; Chen, Lingjun; Luo, Robert; Sickler, Joanna; Liesenfeld, Oliver; Chen, Shuqi
2017-10-01
The performance of a polymerase chain reaction-based point-of-care assay, the cobas Strep A Nucleic Acid Test for use on the cobas Liat System (cobas Liat Strep A assay), for the detection of group A Streptococcus bacteria was evaluated in primary care settings. Throat swab specimens from 427 patients were tested with the cobas Liat Strep A assay and a rapid antigen detection test (RADT) by existing medical staff at 5 primary care clinics, and results were compared with bacterial culture. The cobas Liat Strep A assay demonstrated equivalent sensitivity (97.7%) and specificity (93.3%) to reference culture with a 15-minute turnaround time. In comparison to RADTs, the cobas Liat Strep A assay showed improved sensitivity (97.7% Liat vs 84.5% RADT). The Clinical Laboratory Improvement Amendments-waived cobas Liat Strep A assay demonstrated the ease of use and improved turnaround time of RADTs along with the sensitivity of culture.
Barnfather, Kristian D; Cope, Graham F; Chapple, Iain L
2005-10-29
To investigate the effect of immediate feedback from a point of care test for salivary nicotine metabolites in promoting smoking cessation and reduction in tobacco use. Prospective, operator blinded, randomised controlled trial. General dental practice, London. 100 adult smokers. Participants completed a questionnaire on smoking, undertook a clinical examination, and received counselling in smoking cessation. Saliva samples were analysed at presentation and at eight weeks for salivary nicotine metabolites using a 10 minute semiquantitative point of care test. Smoking cessation measured by salivary nicotine metabolite values (scale 0-6), patient feedback on the perceived value of the test (visual analogue scale) in quitting, and reduction in tobacco use. A higher smoking quit rate was achieved with the point of care test (23% cases v 7% controls; P < 0.039), and overall tobacco use also decreased (68% cases v 28% controls; P < 0.001). Baseline values for salivary nicotine metabolites did not differ between the groups (cases, mean 4.1, SD 1.3 and 4.3, 1.4; P = 0.51). 87 participants reattended at eight weeks (44 cases, 43 controls). Mean nicotine metabolite values at eight weeks were 2.58 (2.0) for cases and 4.29 (1.8) for controls (P < 0.001). Incorporation of individualised personal feedback using a point of care test for salivary nicotine metabolites into a general practice based smoking cessation programme increased quit rates by 17% at eight weeks and reduced tobacco use.
Schvartz, Gili; Epp, Tasha; Burgess, Hilary J; Chilton, Neil B; Lohmann, Katharina L
2015-07-01
To investigate the agreement between available serologic tests for the detection of antibodies against Anaplasma phagocytophilum and Borrelia burgdorferi, 50 serum samples from horses of unknown clinical status and at low risk for infection were tested. In addition to a point-of-care enzyme-linked immunosorbent assay (pocELISA), the evaluated tests included 2 indirect fluorescent antibody tests (IFATs) for antibodies against A. phagocytophilum and an IFAT, an ELISA confirmed with Western blot, and the Lyme multiplex assay for antibodies against B. burgdorferi. For each pair-wise comparison between serologic tests, the difference in the proportion of seropositive results as well as kappa and the prevalence-adjusted, bias-adjusted kappa were calculated. The proportion of seropositive results differed significantly in each pairwise comparison of tests for detection of antibodies against A. phagocytophilum, and between the pocELISA and IFAT as well as between the pocELISA and Lyme multiplex assay for detection of antibodies against B. burgdorferi. Agreement based on kappa varied from poor to fair while agreement was improved when evaluating prevalence-adjusted, bias-adjusted kappa. Lack of agreement may be explained by differences in methodology between the evaluated tests, cross-reactivity or false-positive and false-negative tests. In addition to the limitations of serologic test interpretation in the absence of clinical disease, this data suggest that screening of horses for exposure to tick-borne diseases in nonendemic areas may not be warranted. © 2015 The Author(s).
Hemoglobin A1c Point-of-Care Assays; a New World with a Lot of Consequences!
Lenters-Westra, Erna; Slingerland, Robbert J.
2009-01-01
Background Point-of-care instruments for the measurement of hemoglobin A1c (HbA1c) may improve the glycemic control of people with diabetes by providing a rapid result if the performance of the instruments used is acceptable. A 0.5% HbA1c difference between successive results is considered a clinically relevant change. With this in mind, the In2it from Bio-Rad and the DCA Vantage from Siemens were evaluated according to Clinical and Laboratory Standards Institute (CLSI) protocols. Methods The CLSI protocols EP-5 and EP-9 were applied to investigate precision, accuracy, and bias. The bias was compared with three certified secondary reference measurement procedures. Differences between capillary and venous blood were investigated by an end-user group consisting of nurse practitioners at a diabetes care center. Results At HbA1c levels of 5.1 and 11.2%, total coefficients of variation (CV) for the In2it were 4.9 and 3.3%, respectively, and for the DCA Vantage were 1.7 to 1.8% and 3.7 to 5.5% depending on the lot number of the cartridges. Method comparisons showed significant lot number-dependent results for the In2it and the DCA Vantage compared with the three reference methods. No overall difference was observed between capillary and venous blood for both methods. Conclusion Performance results of the In2it and the DCA Vantage showed variable and lot number-dependent results. To maintain the interlaboratory CV of 5% for HbA1c, the Clinical Laboratory Improvement Amendments rules for waived point-of-care instruments should be revised. An obligation for participating in external quality schemes and taking adequate action should be considered for POC instruments that perform poorly. PMID:20144277
Do, Nga T T; Ta, Ngan T D; Tran, Ninh T H; Than, Hung M; Vu, Bich T N; Hoang, Long B; van Doorn, H Rogier; Vu, Dung T V; Cals, Jochen W L; Chandna, Arjun; Lubell, Yoel; Nadjm, Behzad; Thwaites, Guy; Wolbers, Marcel; Nguyen, Kinh V; Wertheim, Heiman F L
2016-09-01
Inappropriate antibiotic use for acute respiratory tract infections is common in primary health care, but distinguishing serious from self-limiting infections is difficult, particularly in low-resource settings. We assessed whether C-reactive protein point-of-care testing can safely reduce antibiotic use in patients with non-severe acute respiratory tract infections in Vietnam. We did a multicentre open-label randomised controlled trial in ten primary health-care centres in northern Vietnam. Patients aged 1-65 years with at least one focal and one systemic symptom of acute respiratory tract infection were assigned 1:1 to receive either C-reactive protein point-of-care testing or routine care, following which antibiotic prescribing decisions were made. Patients with severe acute respiratory tract infection were excluded. Enrolled patients were reassessed on day 3, 4, or 5, and on day 14 a structured telephone interview was done blind to the intervention. Randomised assignments were concealed from prescribers and patients but not masked as the test result was used to assist treatment decisions. The primary outcome was antibiotic use within 14 days of follow-up. All analyses were prespecified in the protocol and the statistical analysis plan. All analyses were done on the intention-to-treat population and the analysis of the primary endpoint was repeated in the per-protocol population. This trial is registered under number NCT01918579. Between March 17, 2014, and July 3, 2015, 2037 patients (1028 children and 1009 adults) were enrolled and randomised. One adult patient withdrew immediately after randomisation. 1017 patients were assigned to receive C-reactive protein point-of-care testing, and 1019 patients were assigned to receive routine care. 115 patients in the C-reactive protein point-of-care group and 72 patients in the routine care group were excluded in the intention-to-treat analysis due to missing primary endpoint. The number of patients who used antibiotics
Emerging point of care tests for influenza: innovation or status quo.
Tayo, Adeoluwa; Ellis, Joanna; Linden Phillips, Luan; Simpson, Sue; Ward, Derek J
2012-07-01
Point of care tests (POCTs) for influenza potentially offer earlier diagnosis, enabling specific treatment, infection control measures and greater patient convenience and satisfaction. Current POCTs have limited sensitivity, some cannot distinguish influenza types, none differentiate subtypes and are relatively expensive. To identify and characterise influenza POCTs expected to be available for clinical use in the U.K. by mid-2013, highlighting those with potential benefits over existing tests. Potential developers of influenza POCTs were identified through known manufacturers' websites, Medical Technology trade associations, the EuroScan International Network, an expert advisory group and by searching relevant online sources. Identified companies were asked to provide standard information on relevant technologies. Fifty-six companies were identified, and 29 (52%) responded, identifying 57 potentially relevant technologies. Of these, 40 (70%) were already available or had undetermined status and 5 (9%) were excluded as time to results took over 60 minutes. Of the remaining 12 emerging POCTs, 10 (83%) reportedly enabled differentiation of influenza types and eight differentiation of A subtypes. Nasopharyngeal swabs were the most commonly acceptable sample type; the sample volume ranging from 80 μl to 1.4 ml. Most identified emerging influenza POCTs offered differentiation of influenza type and subtype. Tests claiming this capability include several incorporating reverse transcription polymerase chain reaction assays; though, these also had the longest time to result. However, whilst some identified POCTs exhibit high sensitivity and specificity, most lack published clinical data for assessment, and the overall costs of these technologies remains largely unknown. © 2011 Blackwell Publishing Ltd.
Herbst de Cortina, Sasha; Bristow, Claire C; Humphries, Romney; Vargas, Silver Keith; Konda, Kelika A; Caceres, Carlos F; Klausner, Jeffrey D
2017-07-01
Dual point-of-care tests for antibodies to human immunodeficiency virus (HIV) and Treponema pallidum allow for same-day testing and treatment and have been demonstrated to be cost-effective in preventing the adverse outcomes of HIV infection and syphilis. By recording and transmitting data as they are collected, electronic readers address challenges related to the decentralization of point-of-care testing. We evaluated a smartphone-based electronic reader using 201 sera tested with 2 dual rapid tests for detection of antibodies to HIV and T. pallidum in Los Angeles, USA, and Lima, Peru. Tests were read both visually and with the electronic reader. Enzyme immunoassay followed by Western blot and T. pallidum particle agglutination were the reference tests for HIV and T. pallidum, respectively. The sensitivities of the 2 rapid tests for detection of HIV were 94.1% and 97.0% for electronic readings. Both tests had a specificity of 100% for detection of HIV by electronic reading. The sensitivities of the 2 rapid tests for detection of T. pallidum were 86.5% and 92.4% for electronic readings. The specificities for detection of T. pallidum were 99.1% and 99.0% by electronic reading. There were no significant differences between the accuracies of visual and electronic readings, and the performance did not differ between the 2 study sites. Our results show the electronic reader to be a promising option for increasing the use of point-of-care testing programs.
Wirtz, Andrea L; Naing, Soe; Clouse, Emily; Thu, Kaung Htet; Mon, Sandra Hsu Hnin; Tun, Zin Min; Baral, Stefan; Paing, Aung Zayar; Beyrer, Chris
2017-05-17
Efforts to improve HIV diagnosis and antiretroviral therapy (ART) initiation among people living with HIV and reduce onward transmission of HIV rely on innovative interventions along multiple steps of the HIV care continuum. These innovative methods are particularly important for key populations, including men who have sex with men (MSM) and transgender women (TW). The HIV epidemic in Myanmar is concentrated among key populations, and national efforts now focus on reducing stigma and improving engagement of MSM and TW in HIV prevention and care. This study aims to test the use of several innovations to address losses in the HIV care continuum: (1) use of respondent-driven sampling (RDS) to reach and engage MSM and TW in HIV testing, (2) HIV self-testing (HIVST) to increase HIV testing uptake and aid early diagnosis of infection, (3) community-based CD4 point-of-care (POC) technology to rapidly stage HIV disease for those who are HIV infected, and (4) peer navigation support to increase successful health system navigation for HIV-infected MSM and TW in need of ART or HIV engagement in care. To assess the effect of HIVST, we will implement a randomized trial in which MSM and TW adults in the greater Yangon metropolitan area who are HIV uninfected will be recruited via RDS (N=366). Participants will complete a baseline socio-behavioral survey and will be randomized to standard, voluntary counseling and testing (VCT) or to HIVST. Biologic specimens will be collected during this baseline visit for confirmatory testing using dried blood spots. Participants will be asked to return to the study office to complete a second study visit in which they will report their HIV test result and answer questions on the acceptability of the assigned testing method. Aim 1 participants with confirmed HIV infection and who are not engaged in care (N=49) will be offered direct enrollment into Aims 2 and 3, which include immediate CD4 POC and the option for peer navigation, respectively
Acestor, Nathalie; Goett, Jane; Lee, Arthur; Herrick, Tara M; Engelbrecht, Susheela M; Harner-Jay, Claudia M; Howell, Bonnie J; Weigl, Bernhard H
2016-01-01
In recent years, an increasing amount of literature is emerging on candidate urine and blood-based biomarkers associated with incidence and severity of preeclampsia (PE) in pregnant women. While enthusiasm on the usefulness of several of these markers in predicting PE is evolving, essentially all work so far has focused on the needs of high-resource settings and high-income countries, resulting primarily in multi-parameter laboratory assays based on proteomic and metabolomics analysis techniques. These highly complex methods, however, require laboratory capabilities that are rarely available or affordable in low-resource settings (LRS). The importance of quantifying maternal and perinatal risks and identifying which pregnancies can be safely prolonged is also much greater in LRS, where intensive care facilities that can rapidly respond to PE-related health threats for women and infants are limited. For these reasons, simple, low cost, sensitive, and specific point-of-care (POC) tests are needed that can be performed by antenatal health care providers in LRS and that can facilitate decisions about detection and management of PE. Our study aims to provide a comprehensive systematic review of current and emerging blood and urine biomarkers for PE, not only on the basis of their clinical performance, but also of their suitability to be used in LRS-compatible test formats, such as lateral flow and other variants of POC rapid assays.
Cox, Marsha E.; DiNello, Robert K.; Geisberg, Mark; Abbott, April; Roberts, Pacita L.; Hooton, Thomas M.
2015-01-01
Urinary tract infections (UTIs) are frequently encountered in clinical practice and most commonly caused by Escherichia coli and other Gram-negative uropathogens. We tested RapidBac, a rapid immunoassay for bacteriuria developed by Silver Lake Research Corporation (SLRC), compared with standard bacterial culture using 966 clean-catch urine specimens submitted to a clinical microbiology laboratory in an urban academic medical center. RapidBac was performed in accordance with instructions, providing a positive or negative result in 20 min. RapidBac identified as positive 245/285 (sensitivity 86%) samples with significant bacteriuria, defined as the presence of a Gram-negative uropathogen or Staphylococcus saprophyticus at ≥103 CFU/ml. The sensitivities for Gram-negative bacteriuria at ≥104 CFU/ml and ≥105 CFU/ml were 96% and 99%, respectively. The specificity of the test, detecting the absence of significant bacteriuria, was 94%. The sensitivity and specificity of RapidBac were similar on samples from inpatient and outpatient settings, from male and female patients, and across age groups from 18 to 89 years old, although specificity was higher in men (100%) compared with that in women (92%). The RapidBac test for bacteriuria may be effective as an aid in the point-of-care diagnosis of UTIs especially in emergency and primary care settings. PMID:26063858
Floré, Katelijne M J; Delanghe, Joris R
2009-01-01
Current point-of-care testing (POCT) glucometers are based on various test principles. Two major method groups dominate the market: glucose oxidase-based systems and glucose dehydrogenase-based systems using pyrroloquinoline quinone (GDH-PQQ) as a cofactor. The GDH-PQQ-based glucometers are replacing the older glucose oxidase-based systems because of their lower sensitivity for oxygen. On the other hand, the GDH-PQQ test method results in falsely elevated blood glucose levels in peritoneal dialysis patients receiving solutions containing icodextrin (e.g., Extraneal; Baxter, Brussels, Belgium). Icodextrin is metabolized in the systemic circulation into different glucose polymers, but mainly maltose, which interferes with the GDH-PQQ-based method. Clinicians should be aware of this analytical interference. The POCT glucometers based on the GDH-PQQ method should preferably not be used in this high-risk population and POCT glucose results inconsistent with clinical suspicion of hypoglycemic coma should be retested with another testing system.
A1c Gear: Laboratory quality HbA1c measurement at the point of care.
Ejilemele, Adetoun; Unabia, Jamie; Ju, Hyunsu; Petersen, John R
2015-05-20
HbA1c is an important part of assessing the diabetic control and since the use of point-of-care devices for monitoring HbA1c is increasing, it is important to determine how these devices compare to the central laboratory. One hundred and twenty patient samples were analyzed on the Bio-Rad Variant™II and one POC analyzer (Sakae A1c Gear). Three patient sample pools containing ~5%, ~7%, and ~10% HbA1c levels were run over 20 days. Three reagent lots and three instruments were evaluated for the A1c Gear. The 120 patient samples showed strong correlation (R(2)>0.989) when compared to the Variant™II with means=8.06% and 7.81%, for Variant IIand A1c Gear, respectively. Changing reagent lots or instruments had no impact for the A1c Gear. The ~5%, ~7%, and ~10% pools within-run and between-run imprecision was between 0.87-1.33% and 1.03-1.32%, and 1.41-2.35% and 1.24-1.89% with total imprecision of 1.67-2.35% and 1.61-2.31% for the A1c Gear and Variant II, respectively. The A1c Gear showed a small negative bias (0.25% HbA1c) across HbA1c measurement ranges of <11.5%. This bias was, however, acceptable and not considered to be clinically significant. The A1c Gear meets the criteria of total CV <3% leading us to the conclusion that the A1c Gear can give results as precise as the laboratory at the POC. Copyright © 2015. Published by Elsevier B.V.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hamilton, Matthew T.; Finger, John W.; Winzeler, Megan E.
The assessment of wildlife health has been enhanced by the ability of point-of-care (POC) blood analysers to provide biochemical analyses of non-domesticated animals in the field. However, environmental limitations (e.g. temperature, atmospheric humidity and rain) and lack of reference values may inhibit researchers from using such a device with certain wildlife species. Evaluating the use of alternative sample types, such as plasma, in a POC device may afford researchers the opportunity to delay sample analysis and the ability to use banked samples. In this study, we examined fresh whole blood, fresh plasma and frozen plasma (sample type) pH, partial pressuremore » of carbon dioxide (PCO 2), bicarbonate (HCO 3₋), total carbon dioxide (TCO 2), base excess (BE), partial pressure of oxygen (PO 2), oxygen saturation (sO 2) and lactate concentrations in 23 juvenile American alligators (Alligator mississippiensis) using an i-STAT CG4+ cartridge. Our results indicate that sample type had no effect on lactate concentration values (F 2,65 = 0.37, P = 0.963), suggesting that the i-STAT analyser can be used reliably to quantify lactate concentrations in fresh and frozen plasma samples. In contrast, the other seven blood parameters measured by the CG4+ cartridge were significantly affected by sample type. In conclusion, we were able to collect blood samples from all alligators within 2 min of capture to establish preliminary reference ranges for juvenile alligators based on values obtained using fresh whole blood.« less
Hamilton, Matthew T.; Finger, John W.; Winzeler, Megan E.; Tuberville, Tracey D.
2016-01-01
The assessment of wildlife health has been enhanced by the ability of point-of-care (POC) blood analysers to provide biochemical analyses of non-domesticated animals in the field. However, environmental limitations (e.g. temperature, atmospheric humidity and rain) and lack of reference values may inhibit researchers from using such a device with certain wildlife species. Evaluating the use of alternative sample types, such as plasma, in a POC device may afford researchers the opportunity to delay sample analysis and the ability to use banked samples. In this study, we examined fresh whole blood, fresh plasma and frozen plasma (sample type) pH, partial pressure of carbon dioxide (PCO2), bicarbonate (HCO3−), total carbon dioxide (TCO2), base excess (BE), partial pressure of oxygen (PO2), oxygen saturation (sO2) and lactate concentrations in 23 juvenile American alligators (Alligator mississippiensis) using an i-STAT CG4+ cartridge. Our results indicate that sample type had no effect on lactate concentration values (F2,65 = 0.37, P = 0.963), suggesting that the i-STAT analyser can be used reliably to quantify lactate concentrations in fresh and frozen plasma samples. In contrast, the other seven blood parameters measured by the CG4+ cartridge were significantly affected by sample type. Lastly, we were able to collect blood samples from all alligators within 2 min of capture to establish preliminary reference ranges for juvenile alligators based on values obtained using fresh whole blood. PMID:27382469
Hamilton, Matthew T.; Finger, John W.; Winzeler, Megan E.; ...
2016-01-01
The assessment of wildlife health has been enhanced by the ability of point-of-care (POC) blood analysers to provide biochemical analyses of non-domesticated animals in the field. However, environmental limitations (e.g. temperature, atmospheric humidity and rain) and lack of reference values may inhibit researchers from using such a device with certain wildlife species. Evaluating the use of alternative sample types, such as plasma, in a POC device may afford researchers the opportunity to delay sample analysis and the ability to use banked samples. In this study, we examined fresh whole blood, fresh plasma and frozen plasma (sample type) pH, partial pressuremore » of carbon dioxide (PCO 2), bicarbonate (HCO 3₋), total carbon dioxide (TCO 2), base excess (BE), partial pressure of oxygen (PO 2), oxygen saturation (sO 2) and lactate concentrations in 23 juvenile American alligators (Alligator mississippiensis) using an i-STAT CG4+ cartridge. Our results indicate that sample type had no effect on lactate concentration values (F 2,65 = 0.37, P = 0.963), suggesting that the i-STAT analyser can be used reliably to quantify lactate concentrations in fresh and frozen plasma samples. In contrast, the other seven blood parameters measured by the CG4+ cartridge were significantly affected by sample type. In conclusion, we were able to collect blood samples from all alligators within 2 min of capture to establish preliminary reference ranges for juvenile alligators based on values obtained using fresh whole blood.« less
Qiu, Xianbo; Song, Liuwei; Yang, Shuo; Guo, Meng; Yuan, Quan; Ge, Shengxiang; Min, Xiaoping; Xia, Ningshao
2016-01-01
A fast and low-cost method for HBV genotyping especially for genotypes A, B, C and D was developed and tested. A classifier was used to detect and analyze a one-step immunoassay lateral flow strip functionalized with genotype-specific monoclonal antibodies (mAbs) on multiple capture lines in the form of pattern recognition for point-of-care (POC) diagnostics. The fluorescent signals from the capture lines and the background of the strip were collected via multiple optical channels in parallel. A digital HBV genotyping model, whose inputs are the fluorescent signals and outputs are a group of genotype-specific digital binary codes (0/1), was developed based on the HBV genotyping strategy. Meanwhile, a companion decoding table was established to cover all possible pairing cases between the states of a group of genotype-specific digital binary codes and the HBV genotyping results. A logical analyzing module was constructed to process the detected signals in parallel without program control, and its outputs were used to drive a set of LED indicators, which determine the HBV genotype. Comparing to the nucleic acid analysis to HBV viruses, much faster HBV genotyping with significantly lower cost can be obtained with the developed method. PMID:27306485
Ge, Lei; Yan, Jixian; Song, Xianrang; Yan, Mei; Ge, Shenguang; Yu, Jinghua
2012-02-01
In this work, electrochemiluminescence (ECL) immunoassay was introduced into the recently proposed microfluidic paper-based analytical device (μPADs) based on directly screen-printed electrodes on paper for the very first time. The screen-printed paper-electrodes will be more important for further development of this paper-based ECL device in simple, low-cost and disposable application than commercialized ones. To further perform high-performance, high-throughput, simple and inexpensive ECL immunoassay on μPAD for point-of-care testing, a wax-patterned three-dimensional (3D) paper-based ECL device was demonstrated for the very first time. In this 3D paper-based ECL device, eight carbon working electrodes including their conductive pads were screen-printed on a piece of square paper and shared the same Ag/AgCl reference and carbon counter electrodes on another piece of square paper after stacking. Using typical tris-(bipyridine)-ruthenium (Ⅱ) - tri-n-propylamine ECL system, the application test of this 3D paper-based ECL device was performed through the diagnosis of four tumor markers in real clinical serum samples. With the aid of a facile device-holder and a section-switch assembled on the analyzer, eight working electrodes were sequentially placed into the circuit to trigger the ECL reaction in the sweeping range from 0.5 to 1.1 V at room temperature. In addition, this 3D paper-based ECL device can be easily integrated and combined with the recently emerging paper electronics to further develop simple, sensitive, low-cost, disposable and portable μPAD for point-of-care testing, public health and environmental monitoring in remote regions, developing or developed countries. Copyright © 2011 Elsevier Ltd. All rights reserved.
Afonso, J; Lopes, S; Gonçalves, R; Caldeira, P; Lago, P; Tavares de Sousa, H; Ramos, J; Gonçalves, A R; Ministro, P; Rosa, I; Vieira, A I; Dias, C C; Magro, F
2016-10-01
Therapeutic drug monitoring is a powerful strategy known to improve the clinical outcomes and to optimise the healthcare resources in the treatment of autoimmune diseases. Currently, most of the methods commercially available for the quantification of infliximab (IFX) are ELISA-based, with a turnaround time of approximately 8 h, and delaying the target dosage adjustment to the following infusion. To validate the first point-of-care IFX quantification device available in the market - the Quantum Blue Infliximab assay (Buhlmann, Schonenbuch, Switzerland) - by comparing it with two well-established methods. The three methods were used to assay the IFX concentration of spiked samples and of the serum of 299 inflammatory bowel diseases (IBD) patients undergoing IFX therapy. The point-of-care assay had an average IFX recovery of 92%, being the most precise among the tested methods. The Intraclass Correlation Coefficients of the point-of-care IFX assay vs. the two ELISA-based established methods were 0.889 and 0.939. Moreover, the accuracy of the point-of-care IFX compared with each of the two reference methods was 77% and 83%, and the kappa statistics revealed a substantial agreement (0.648 and 0.738). The Quantum Blue IFX assay can successfully replace the commonly used ELISA-based IFX quantification kits. This point-of-care IFX assay is able to deliver the results within 15 min makes it ideal for an immediate target concentration adjusted dosing. Moreover, it is a user-friendly desktop device that does not require specific laboratory facilities or highly specialised personnel. © 2016 John Wiley & Sons Ltd.
Programmable Bio-nanochip Platform: A Point-of-Care Biosensor System with the Capacity To Learn.
McRae, Michael P; Simmons, Glennon; Wong, Jorge; McDevitt, John T
2016-07-19
The combination of point-of-care (POC) medical microdevices and machine learning has the potential transform the practice of medicine. In this area, scalable lab-on-a-chip (LOC) devices have many advantages over standard laboratory methods, including faster analysis, reduced cost, lower power consumption, and higher levels of integration and automation. Despite significant advances in LOC technologies over the years, several remaining obstacles are preventing clinical implementation and market penetration of these novel medical microdevices. Similarly, while machine learning has seen explosive growth in recent years and promises to shift the practice of medicine toward data-intensive and evidence-based decision making, its uptake has been hindered due to the lack of integration between clinical measurements and disease determinations. In this Account, we describe recent developments in the programmable bio-nanochip (p-BNC) system, a biosensor platform with the capacity for learning. The p-BNC is a "platform to digitize biology" in which small quantities of patient sample generate immunofluorescent signal on agarose bead sensors that is optically extracted and converted to antigen concentrations. The platform comprises disposable microfluidic cartridges, a portable analyzer, automated data analysis software, and intuitive mobile health interfaces. The single-use cartridges are fully integrated, self-contained microfluidic devices containing aqueous buffers conveniently embedded for POC use. A novel fluid delivery method was developed to provide accurate and repeatable flow rates via actuation of the cartridge's blister packs. A portable analyzer instrument was designed to integrate fluid delivery, optical detection, image analysis, and user interface, representing a universal system for acquiring, processing, and managing clinical data while overcoming many of the challenges facing the widespread clinical adoption of LOC technologies. We demonstrate the p
Brangel, Polina; Sobarzo, Ariel; Parolo, Claudio; Miller, Benjamin S; Howes, Philip D; Gelkop, Sigal; Lutwama, Julius J; Dye, John M; McKendry, Rachel A; Lobel, Leslie; Stevens, Molly M
2018-01-23
Ebola virus disease causes widespread and highly fatal epidemics in human populations. Today, there is still great need for point-of-care tests for diagnosis, patient management and surveillance, both during and post outbreaks. We present a point-of-care test comprising an immunochromatographic strip and a smartphone reader, which detects and semiquantifies Ebola-specific antibodies in human survivors. We developed a Sudan virus glycoprotein monoplex platform and validated it using sera from 90 human survivors and 31 local noninfected controls. The performance of the glycoprotein monoplex was 100% sensitivity and 98% specificity compared to standard whole antigen enzyme-linked immunosorbent assay (ELISA), and it was validated with freshly collected patient samples in Uganda. Moreover, we constructed a multiplex test for simultaneous detection of antibodies against three recombinant Sudan virus proteins. A pilot study comprising 15 survivors and 5 noninfected controls demonstrated sensitivity and specificity of 100% compared to standard ELISA. Finally, we developed a second multiplex subtype assay for the identification of exposure to three related EVD species: Sudan virus, Bundibugyo virus and Ebola virus (formerly Zaire) using recombinant viral glycoprotein. This multiplex test could distinguish between the host's immunity to specific viral species and identify cross-reactive immunity. These developed serological platforms consisted of capture ligands with high specificity and sensitivity, in-house developed strips and a compatible smartphone application. These platforms enabled rapid and portable testing, data storage and sharing as well as geographical tagging of the tested individuals in Uganda. This platform holds great potential as a field tool for diagnosis, vaccine development, and therapeutic evaluation.
Sun, Alexander C.; Yao, Chengyang; Venkatesh, A. G.; Hall, Drew A.
2016-01-01
Cellular phone penetration has grown continually over the past two decades with the number of connected devices rapidly approaching the total world population. Leveraging the worldwide ubiquity and connectivity of these devices, we developed a mobile phone-based electrochemical biosensor platform for point-of-care (POC) diagnostics and wellness tracking. The platform consists of an inexpensive electronic module (< $20) containing a low-power potentiostat that interfaces with and efficiently harvests power from a wide variety of phones through the audio jack. Active impedance matching improves the harvesting efficiency to 79%. Excluding loses from supply rectification and regulation, the module consumes 6.9 mW peak power and can measure < 1 nA bidirectional current. The prototype was shown to operate within the available power budget set by mobile devices and produce data that matches well with that of an expensive laboratory grade instrument. We demonstrate that the platform can be used to track the concentration of secretory leukocyte protease inhibitor (SLPI), a biomarker for monitoring lung infections in cystic fibrosis patients, in its physiological range via an electrochemical sandwich assay on disposable screen-printed electrodes with a 1 nM limit of detection. PMID:27725788
Providing HIV results via SMS one day after testing: more popular than rapid point-of-care tests.
Davies, Stephen C; Koh, Andrew; Lindsay, Heather E; Fulton, Richard B; Fernando, Suran L
2017-06-01
An inner Sydney sexual health service introduced the option to gay and bisexual men of receiving a negative HIV result by SMS to mobile phone one business day after venipuncture (rapid SMS). Men could also choose one of the other options: a point-of-care-test (POCT), by phone, or in-person (clinicians could also require in-person). We followed-up patients choosing the rapid SMS method to ascertain their satisfaction. During 12 months, 473 men had 591 HIV tests. Of these tests, 5.4% were POCTs, 9.1% were in-person, 24% were by phone, and 62% were rapid SMS. HIV POCTs declined from being 22% of result methods in the pre-study period to 5.4% during the rapid SMS intervention period (odds ratio 0.20, 95% CI 0.13-0.32, P < 0.0001). Phone/in-person results declined from 78% to 33% (odds ratio 0.14, 95% CI 0.10-0.20, P < 0.0001). SMS was sent by the next business day in 95% of cases; 96% of men were satisfied; and 95% would choose this method for their next test. Of 77 men who previously had an HIV POCT, 56 (73%) elected a rapid SMS result rather than having another POCT. The higher accuracy of conventional serology was commonly expressed as the reason for choosing rapid SMS for results.
Hislop, J; Quayyum, Z; Flett, G; Boachie, C; Fraser, C; Mowatt, G
2010-06-01
To assess whether or not the Chlamydia Rapid Test (CRT) could improve detection of genital chlamydia, and whether it is more effective than current practice using nucleic acid amplification tests (NAATs), in terms of the number of cases of chlamydia that are detected and treated and the proportion of partners identified and treated. Eleven electronic bibliographic databases (including MEDLINE and EMBASE) were searched until November 2008, as well as relevant websites. Studies of sexually active adolescent and adult women and men suspected of having or being tested for genital chlamydia infection were considered. The tests considered were the CRT and other comparator point-of-care tests identified, using a NAAT as a reference standard. Summary sensitivity, specificity, positive and negative likelihood ratios, and diagnostic odds ratios for each model were reported as a median and a 95% confidence interval (CI). Effectiveness was measured in terms of the absolute numbers of true-positives, false-positives, false-negatives (and other positive cases missed) and true-negatives detected. Costs were considered from the health service's perspective. Incremental cost-effectiveness ratios were used to examine the relative cost-effectiveness, and values of the major parameters of the models were varied in a sensitivity analysis. Thirteen studies enrolling 8817 participants were included in the analysis. In the pooled estimates for the CRT, sensitivity (95% CI) was 80% (73% to 85%) for vaginal swab specimens and 77% (59% to 89%) for first void urine (FVU) specimens. Specificity was 99% (99% to 100%) for vaginal swab specimens and 99% (98% to 99%) for FVU specimens. In the pooled estimates for a comparator point-of-care test (Clearview Chlamydia), sensitivity (95% CI) was 52% (39% to 65%) for vaginal, cervical and urethral swab specimens combined, and 64% (47% to 77%) for cervical specimens alone. Specificity was 97% (94% to 100%) for vaginal, cervical and urethral swab
Kuznik, Andreas; Lamorde, Mohammed; Nyabigambo, Agnes; Manabe, Yukari C
2013-11-01
Untreated syphilis in pregnancy is associated with adverse clinical outcomes for the infant. Most syphilis infections occur in sub-Saharan Africa (SSA), where coverage of antenatal screening for syphilis is inadequate. Recently introduced point-of-care syphilis tests have high accuracy and demonstrate potential to increase coverage of antenatal screening. However, country-specific cost-effectiveness data for these tests are limited. The objective of this analysis was to evaluate the cost-effectiveness and budget impact of antenatal syphilis screening for 43 countries in SSA and estimate the impact of universal screening on stillbirths, neonatal deaths, congenital syphilis, and disability-adjusted life years (DALYs) averted. The decision analytic model reflected the perspective of the national health care system and was based on the sensitivity (86%) and specificity (99%) reported for the immunochromatographic strip (ICS) test. Clinical outcomes of infants born to syphilis-infected mothers on the end points of stillbirth, neonatal death, and congenital syphilis were obtained from published sources. Treatment was assumed to consist of three injections of benzathine penicillin. Country-specific inputs included the antenatal prevalence of syphilis, annual number of live births, proportion of women with at least one antenatal care visit, per capita gross national income, and estimated hourly nurse wages. In all 43 sub-Saharan African countries analyzed, syphilis screening is highly cost-effective, with an average cost/DALY averted of US$11 (range: US$2-US$48). Screening remains highly cost-effective even if the average prevalence falls from the current rate of 3.1% (range: 0.6%-14.0%) to 0.038% (range: 0.002%-0.113%). Universal antenatal screening of pregnant women in clinics may reduce the annual number of stillbirths by up to 64,000, neonatal deaths by up to 25,000, and annual incidence of congenital syphilis by up to 32,000, and avert up to 2.6 million DALYs at an
A miniaturised image based fluorescence detection system for point-of-care-testing of cocaine abuse
NASA Astrophysics Data System (ADS)
Walczak, Rafał; Krüger, Jan; Moynihan, Shane
2015-08-01
In this paper, we describe a miniaturised image-based fluorescence detection system and demonstrate its viability as a highly sensitive tool for point-of-care-analysis of drugs of abuse in human sweat with a focus on monitor individuals for drugs of abuse. Investigations of miniaturised and low power optoelectronic configurations and methodologies for real-time image analysis were successfully carried out. The miniaturised fluorescence detection system was validated against a reference detection system under controlled laboratory conditions by analysing spiked sweat samples in dip stick and then strip with sample pad. As a result of the validation studies, a 1 ng mL-1 limit of detection of cocaine in sweat and full agreement of test results with the reference detection system can be reported. Results of the investigations open the way towards a detection system that integrates a hand-held fluorescence reader and a wearable skinpatch, and which can collect and in situ analyse sweat for the presence of cocaine at any point for up to tenths hours.
Cai, Yihua; Guo, Laodong; Wang, Xuri; Aiken, George R.
2015-01-01
Sources, abundance, isotopic compositions, and export fluxes of dissolved inorganic carbon (DIC), dissolved and colloidal organic carbon (DOC and COC), and particulate organic carbon (POC), and their response to hydrologic regimes were examined through monthly sampling from the Lower Mississippi River during 2006–2008. DIC was the most abundant carbon species, followed by POC and DOC. Concentration and δ13C of DIC decreased with increasing river discharge, while those of DOC remained fairly stable. COC comprised 61 ± 3% of the bulk DOC with similar δ13C abundances but higher percentages of hydrophobic organic acids than DOC, suggesting its aromatic and diagenetically younger status. POC showed peak concentrations during medium flooding events and at the rising limb of large flooding events. While δ13C-POC increased, δ15N of particulate nitrogen decreased with increasing discharge. Overall, the differences in δ13C between DOC or DIC and POC show an inverse correlation with river discharge. The higher input of soil organic matter and respired CO2 during wet seasons was likely the main driver for the convergence of δ13C between DIC and DOC or POC, whereas enhanced in situ primary production and respiration during dry seasons might be responsible for their isotopic divergence. Carbon export fluxes from the Mississippi River were estimated to be 13.6 Tg C yr−1 for DIC, 1.88 Tg C yr−1 for DOC, and 2.30 Tg C yr−1 for POC during 2006–2008. The discharge-normalized DIC yield decreased during wet seasons, while those of POC and DOC increased and remained constant, respectively, implying variable responses in carbon export to the increasing discharge.
A Novel Molecular Test to Diagnose Canine Visceral Leishmaniasis at the Point of Care
Castellanos-Gonzalez, Alejandro; Saldarriaga, Omar A.; Tartaglino, Lilian; Gacek, Rosana; Temple, Elissa; Sparks, Hayley; Melby, Peter C.; Travi, Bruno L.
2015-01-01
Dogs are the principal reservoir hosts of zoonotic visceral leishmaniasis (VL) but current serological methods are not sensitive enough to detect all subclinically infected animals, which is crucial to VL control programs. Polymerase chain reaction (PCR) methods have greater sensitivity but require expensive equipment and trained personnel, impairing its implementation in endemic areas. We developed a diagnostic test that uses isothermal recombinase polymerase amplification (RPA) to detect Leishmania infantum. This method was coupled with lateral flow (LF) reading with the naked eye to be adapted as a point-of-care test. The L. infantum RPA-LF had an analytical sensitivity similar to real time-PCR, detecting DNA of 0.1 parasites spiked in dog blood, which was equivalent to 40 parasites/mL. There was no cross amplification with dog or human DNA or with Leishmania braziliensis, Leishmania amazonensis, or Trypanosoma cruzi. The test also amplified Leishmania donovani strains (N = 7). In a group of clinically normal dogs (N = 30), RPA-LF detected more subclinical infections than rK39 strip test, a standard serological method (50% versus 13.3% positivity, respectively; P = 0.005). Also, RPA-LF detected L. infantum in noninvasive mucosal samples of dogs with a sensitivity comparable to blood samples. This novel molecular test may have a positive impact in leishmaniasis control programs. PMID:26240156
Leis, Jerome A; Palmay, Lesley; Ho, Grace; Raybardhan, Sumit; Gill, Suzanne; Kan, Tiffany; Campbell, Jackie; Kiss, Alex; McCready, Janine B; Das, Pavani; Minnema, Brian; Powis, Jeff E; Walker, Sandra A N; Ferguson, Heather; Wong, Benny; Weber, Elizabeth
2017-06-01
Beta-lactam allergy skin testing (BLAST) is recommended by antimicrobial stewardship program (ASP) guidelines, yet few studies have systematically evaluated its impact when delivered at point-of-care. We conducted a pragmatic multicenter prospective evaluation of the use of point-of-care BLAST by ASPs. In staggered 3-month intervals, ASP teams at three hospitals received training by allergists to offer BLAST for eligible patients with infectious diseases receiving non-preferred beta-lactam therapy due to severity of their allergy. The primary outcome was the proportion of patients receiving the preferred beta-lactam therapy. Of 827 patients with reported beta-lactam allergy over 15-months, beta-lactam therapy was preferred among 632(76%). During baseline periods, 50% (124/246) received preferred beta-lactam therapy based on history, compared with 60% (232/386) during the intervention periods (p=0.02), which improved further to 81% (313/386) upon provision of BLAST (p<0.001) without any increase in incidence of adverse drug reactions (4% vs. 3%; p=0.4). After adjusting for patient variables and the correlation between hospitals, the intervention period was associated with a 4.5-fold greater odds of receiving preferred beta-lactam therapy (95% CI, 2.4-8.2; p<0.0001). The use of BLAST at the point-of-care across three hospital ASPs resulted in greater use of preferred beta-lactam therapy without increasing the risk of adverse drug reactions. Longer term studies are needed to better assess the safety and clinical impact of this ASP intervention. © The Author 2017. Published by Oxford University Press for the Infectious Diseases Society of America. All rights reserved. For permissions, e-mail: journals.permissions@oup.com.
Iapichino, Giacomo E; Bianchi, Paolo; Ranucci, Marco; Baryshnikova, Ekaterina
2017-06-01
Direct oral anticoagulants (DOACs) exert similar anticoagulant effects to vitamin K antagonists and are increasingly used worldwide. Nevertheless, an evidence-based approach to patients receiving DOACs when any unplanned urgent surgery or bleeding (either spontaneous or traumatic) occurs is still missing. In this review, we investigate the role of point-of-care coagulation tests when other, more specific tests are not available. Indeed, thromboelastography and activated clotting time can detect dabigatran-induced coagulopathy, while their accuracy is limited for apixaban and rivaroxaban, mostly in cases of low drug plasma concentrations. These tests can also be used to guide the reversal of DOAC-induced coagulopathy providing a quick, before-and-after picture in case of therapeutic use of hemostatic compounds. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.
POC1A Truncation Mutation Causes a Ciliopathy in Humans Characterized by Primordial Dwarfism
Shaheen, Ranad; Faqeih, Eissa; Shamseldin, Hanan E.; Noche, Ramil R.; Sunker, Asma; Alshammari, Muneera J.; Al-Sheddi, Tarfa; Adly, Nouran; Al-Dosari, Mohammed S.; Megason, Sean G.; Al-Husain, Muneera; Al-Mohanna, Futwan; Alkuraya, Fowzan S.
2012-01-01
Primordial dwarfism (PD) is a phenotype characterized by profound growth retardation that is prenatal in onset. Significant strides have been made in the last few years toward improved understanding of the molecular underpinning of the limited growth that characterizes the embryonic and postnatal development of PD individuals. These include impaired mitotic mechanics, abnormal IGF2 expression, perturbed DNA-damage response, defective spliceosomal machinery, and abnormal replication licensing. In three families affected by a distinct form of PD, we identified a founder truncating mutation in POC1A. This gene is one of two vertebrate paralogs of POC1, which encodes one of the most abundant proteins in the Chlamydomonas centriole proteome. Cells derived from the index individual have abnormal mitotic mechanics with multipolar spindles, in addition to clearly impaired ciliogenesis. siRNA knockdown of POC1A in fibroblast cells recapitulates this ciliogenesis defect. Our findings highlight a human ciliopathy syndrome caused by deficiency of a major centriolar protein. PMID:22840364
Microfluidic "Pouch" Chips for Immunoassays and Nucleic Acid Amplification Tests.
Mauk, Michael G; Liu, Changchun; Qiu, Xianbo; Chen, Dafeng; Song, Jinzhao; Bau, Haim H
2017-01-01
Microfluidic cassettes ("chips") for processing and analysis of clinical specimens and other sample types facilitate point-of-care (POC) immunoassays and nucleic acid based amplification tests. These single-use test chips can be self-contained and made amenable to autonomous operation-reducing or eliminating supporting instrumentation-by incorporating laminated, pliable "pouch" and membrane structures for fluid storage, pumping, mixing, and flow control. Materials and methods for integrating flexible pouch compartments and diaphragm valves into hard plastic (e.g., acrylic and polycarbonate) microfluidic "chips" for reagent storage, fluid actuation, and flow control are described. We review several versions of these pouch chips for immunoassay and nucleic acid amplification tests, and describe related fabrication techniques. These protocols thus offer a "toolbox" of methods for storage, pumping, and flow control functions in microfluidic devices.
Proof of concept testing report.
DOT National Transportation Integrated Search
2008-09-17
This report documents the methodology and results of the U.S. Department of : Transportation (USDOT) Next Generation 9-1-1 Initiative (NG9-1-1) Proof of Concept : (POC) testing. It describes in detail the NG9-1-1 POC test results and provides a basel...
Comparison of point-of-care-compatible lysis methods for bacteria and viruses.
Heiniger, Erin K; Buser, Joshua R; Mireles, Lillian; Zhang, Xiaohong; Ladd, Paula D; Lutz, Barry R; Yager, Paul
2016-09-01
Nucleic acid sample preparation has been an especially challenging barrier to point-of-care nucleic acid amplification tests in low-resource settings. Here we provide a head-to-head comparison of methods for lysis of, and nucleic acid release from, several pathogenic bacteria and viruses-methods that are adaptable to point-of-care usage in low-resource settings. Digestion with achromopeptidase, a mixture of proteases and peptidoglycan-specific hydrolases, followed by thermal deactivation in a boiling water bath, effectively released amplifiable nucleic acid from Staphylococcus aureus, Bordetella pertussis, respiratory syncytial virus, and influenza virus. Achromopeptidase was functional after dehydration and reconstitution, even after eleven months of dry storage without refrigeration. Mechanical lysis methods proved to be effective against a hard-to-lyse Mycobacterium species, and a miniature bead-mill, the AudioLyse, is shown to be capable of releasing amplifiable DNA and RNA from this species. We conclude that point-of-care-compatible sample preparation methods for nucleic acid tests need not introduce amplification inhibitors, and can provide amplification-ready lysates from a wide range of bacterial and viral pathogens. Copyright © 2016. Published by Elsevier B.V.
Kuznik, Andreas; Lamorde, Mohammed; Nyabigambo, Agnes; Manabe, Yukari C.
2013-01-01
Background Untreated syphilis in pregnancy is associated with adverse clinical outcomes for the infant. Most syphilis infections occur in sub-Saharan Africa (SSA), where coverage of antenatal screening for syphilis is inadequate. Recently introduced point-of-care syphilis tests have high accuracy and demonstrate potential to increase coverage of antenatal screening. However, country-specific cost-effectiveness data for these tests are limited. The objective of this analysis was to evaluate the cost-effectiveness and budget impact of antenatal syphilis screening for 43 countries in SSA and estimate the impact of universal screening on stillbirths, neonatal deaths, congenital syphilis, and disability-adjusted life years (DALYs) averted. Methods and Findings The decision analytic model reflected the perspective of the national health care system and was based on the sensitivity (86%) and specificity (99%) reported for the immunochromatographic strip (ICS) test. Clinical outcomes of infants born to syphilis-infected mothers on the end points of stillbirth, neonatal death, and congenital syphilis were obtained from published sources. Treatment was assumed to consist of three injections of benzathine penicillin. Country-specific inputs included the antenatal prevalence of syphilis, annual number of live births, proportion of women with at least one antenatal care visit, per capita gross national income, and estimated hourly nurse wages. In all 43 sub-Saharan African countries analyzed, syphilis screening is highly cost-effective, with an average cost/DALY averted of US$11 (range: US$2–US$48). Screening remains highly cost-effective even if the average prevalence falls from the current rate of 3.1% (range: 0.6%–14.0%) to 0.038% (range: 0.002%–0.113%). Universal antenatal screening of pregnant women in clinics may reduce the annual number of stillbirths by up to 64,000, neonatal deaths by up to 25,000, and annual incidence of congenital syphilis by up to 32,000, and
ASVCP guidelines: quality assurance for point-of-care testing in veterinary medicine.
Flatland, Bente; Freeman, Kathleen P; Vap, Linda M; Harr, Kendal E
2013-12-01
Point-of-care testing (POCT) refers to any laboratory testing performed outside the conventional reference laboratory and implies close proximity to patients. Instrumental POCT systems consist of small, handheld or benchtop analyzers. These have potential utility in many veterinary settings, including private clinics, academic veterinary medical centers, the community (eg, remote area veterinary medical teams), and for research applications in academia, government, and industry. Concern about the quality of veterinary in-clinic testing has been expressed in published veterinary literature; however, little guidance focusing on POCT is available. Recognizing this void, the ASVCP formed a subcommittee in 2009 charged with developing quality assurance (QA) guidelines for veterinary POCT. Guidelines were developed through literature review and a consensus process. Major recommendations include (1) taking a formalized approach to POCT within the facility, (2) use of written policies, standard operating procedures, forms, and logs, (3) operator training, including periodic assessment of skills, (4) assessment of instrument analytical performance and use of both statistical quality control and external quality assessment programs, (5) use of properly established or validated reference intervals, (6) and ensuring accurate patient results reporting. Where possible, given instrument analytical performance, use of a validated 13s control rule for interpretation of control data is recommended. These guidelines are aimed at veterinarians and veterinary technicians seeking to improve management of POCT in their clinical or research setting, and address QA of small chemistry and hematology instruments. These guidelines are not intended to be all-inclusive; rather, they provide a minimum standard for maintenance of POCT instruments in the veterinary setting. © 2013 American Society for Veterinary Clinical Pathology and European Society for Veterinary Clinical Pathology.
Ko, Byuk Sung; Kim, Won Young; Ryoo, Seung Mok; Ahn, Shin; Sohn, Chang Hwan; Seo, Dong Woo; Lee, Yoon-Seon; Lim, Kyoung Soo; Jung, Hwoon-Yong
2015-11-01
It is difficult to assess risk in normotensive patients with upper gastrointestinal bleeding. The aim of this study was to evaluate whether the initial lactate value can predict the in-hospital occurrence of hypotension in stable patients with acute nonvariceal upper gastrointestinal bleeding. Retrospective, observational, single-center study. Emergency department of a tertiary-care, university-affiliated hospital during a 5-year period. Medical records of 3,489 patients with acute upper gastrointestinal bleeding who were normotensive at presentation to the emergency department. We analyzed the ability of point-of-care testing of lactate at emergency department admission to predict hypotension development (defined as systolic blood pressure <90 mm Hg) within 24 hours after emergency department admission. None. Of the 1,003 patients with acute nonvariceal upper gastrointestinal bleeding, 157 patients experienced hypotension within 24 hours. Lactate was independently associated with hypotension development (odds ratio, 1.6; 95% CI, 1.4-1.7), and the risk of hypotension significantly increased as the lactate increased from 2.5-4.9 mmol/L (odds ratio, 2.2) to 5.0-7.4 mmol/L (odds ratio, 4.0) and to greater than or equal to 7.5 mmol/L (odds ratio, 39.2) (p<0.001). Lactate elevation (≥2.5 mmol/L) was associated with 90% specificity and an 84% negative predictive value for hypotension development. When the lactate levels were greater than 5.0 mmol/L, the specificity and negative predictive value increased to 98% and 87%, respectively. Point-of-care testing of lactate can predict in-hospital occurrence of hypotension in stable patients with acute nonvariceal upper gastrointestinal bleeding. However, subsequently, prospective validate research will be required to clarify this.
Point-of-care ultrasonography by pediatric emergency medicine physicians.
Marin, Jennifer R; Lewiss, Resa E
2015-04-01
Emergency physicians have used point-of-care ultrasonography since the 1990 s. Pediatric emergency medicine physicians have more recently adopted this technology. Point-of-care ultrasonography is used for various scenarios, particularly the evaluation of soft tissue infections or blunt abdominal trauma and procedural guidance. To date, there are no published statements from national organizations specifically for pediatric emergency physicians describing the incorporation of point-of-care ultrasonography into their practice. This document outlines how pediatric emergency departments may establish a formal point-of-care ultrasonography program. This task includes appointing leaders with expertise in point-of-care ultrasonography, effectively training and credentialing physicians in the department, and providing ongoing quality assurance reviews. Copyright © 2015 by the American Academy of Pediatrics.
Chan, Rachel; Stieda, Vivian
2011-03-01
Point of care resources make it easier for clinicians to find answers to questions that arise during a clinical encounter. In order to make informed purchase decisions in times of tight budgets, librarians need to have a better understanding of which resources will meet their patrons' clinical information needs. The goal of this study was to assess the content, interface and usability of three point-of-care tools: BMJ Point-of-Care, Clin-eguide and Nursing Reference Centre. A questionnaire designed to gather quantitative and qualitative data was created using Survey Monkey. The survey was distributed to healthcare practitioners in Alberta's two largest health regions, and the data were analysed for emergent themes. The themes that arose--ease of use, validated content, relevancy to practice--generally echoed those stated in the literature. No one database fared significantly better, due to differing features, content and client preference. Despite the limitations of the survey, the themes that emerged provide a springboard for future research on the efficacy of information resources used at the point of care, and the need for deeper analysis of these recent additions to the medical information market. © 2010 The authors. Health Information and Libraries Journal © 2010 Health Libraries Group.
Theron, Grant; Zijenah, Lynn; Chanda, Duncan; Clowes, Petra; Rachow, Andrea; Lesosky, Maia; Bara, Wilbert; Mungofa, Stanley; Pai, Madhukar; Hoelscher, Michael; Dowdy, David; Pym, Alex; Mwaba, Peter; Mason, Peter; Peter, Jonny; Dheda, Keertan
2014-02-01
The Xpert MTB/RIF test for tuberculosis is being rolled out in many countries, but evidence is lacking regarding its implementation outside laboratories, ability to inform same-day treatment decisions at the point of care, and clinical effect on tuberculosis-related morbidity. We aimed to assess the feasibility, accuracy, and clinical effect of point-of-care Xpert MTB/RIF testing at primary-care health-care facilities in southern Africa. In this pragmatic, randomised, parallel-group, multicentre trial, we recruited adults with symptoms suggestive of active tuberculosis from five primary-care health-care facilities in South Africa, Zimbabwe, Zambia, and Tanzania. Eligible patients were randomly assigned using pregenerated tables to nurse-performed Xpert MTB/RIF at the clinic or sputum smear microscopy. Participants with a negative test result were empirically managed according to local WHO-compliant guidelines. Our primary outcome was tuberculosis-related morbidity (measured with the TBscore and Karnofsky performance score [KPS]) in culture-positive patients who had begun anti-tuberculosis treatment, measured at 2 months and 6 months after randomisation, analysed by intention to treat. This trial is registered with Clinicaltrials.gov, number NCT01554384. Between April 12, 2011, and March 30, 2012, we randomly assigned 758 patients to smear microscopy (182 culture positive) and 744 to Xpert MTB/RIF (185 culture positive). Median TBscore in culture-positive patients did not differ between groups at 2 months (2 [IQR 0-3] in the smear microscopy group vs 2 [0·25-3] in the MTB/RIF group; p=0·85) or 6 months (1 [0-3] vs 1 [0-3]; p=0·35), nor did median KPS at 2 months (80 [70-90] vs 90 [80-90]; p=0·23) or 6 months (100 [90-100] vs 100 [90-100]; p=0·85). Point-of-care MTB/RIF had higher sensitivity than microscopy (154 [83%] of 185 vs 91 [50%] of 182; p=0·0001) but similar specificity (517 [95%] 544 vs 540 [96%] of 560; p=0·25), and had similar sensitivity to
Boppart, Stephen A; Richards-Kortum, Rebecca
2014-09-10
Leveraging advances in consumer electronics and wireless telecommunications, low-cost, portable optical imaging devices have the potential to improve screening and detection of disease at the point of care in primary health care settings in both low- and high-resource countries. Similarly, real-time optical imaging technologies can improve diagnosis and treatment at the point of procedure by circumventing the need for biopsy and analysis by expert pathologists, who are scarce in developing countries. Although many optical imaging technologies have been translated from bench to bedside, industry support is needed to commercialize and broadly disseminate these from the patient level to the population level to transform the standard of care. This review provides an overview of promising optical imaging technologies, the infrastructure needed to integrate them into widespread clinical use, and the challenges that must be addressed to harness the potential of these technologies to improve health care systems around the world. Copyright © 2014, American Association for the Advancement of Science.
Point-of-care and point-of-procedure optical imaging technologies for primary care and global health
Boppart, Stephen A.; Richards-Kortum, Rebecca
2015-01-01
Leveraging advances in consumer electronics and wireless telecommunications, low-cost, portable optical imaging devices have the potential to improve screening and detection of disease at the point of care in primary health care settings in both low- and high-resource countries. Similarly, real-time optical imaging technologies can improve diagnosis and treatment at the point of procedure by circumventing the need for biopsy and analysis by expert pathologists, who are scarce in developing countries. Although many optical imaging technologies have been translated from bench to bedside, industry support is needed to commercialize and broadly disseminate these from the patient level to the population level to transform the standard of care. This review provides an overview of promising optical imaging technologies, the infrastructure needed to integrate them into widespread clinical use, and the challenges that must be addressed to harness the potential of these technologies to improve health care systems around the world. PMID:25210062
Stephen, Stephen; Muchaneta-Kubara, Chiwoneso Gwyneth Elizabeth; Munjoma, Marshall Wesley; Mandozana, Gibson
2017-01-01
Cervical chlamydia infection poses high risk of pregnancy complications and neonatal infection. Reference methods for the detection of chlamydia infection are not available for routine use in developing countries. Point-of-care (POC) tests can bridge this gap. This study evaluated Cortez Onestep Chlamydia Rapicard™ insta test for the detection of Chlamydia trachomatis in pregnant women at Mbare Polyclinic and determined the prevalence of C. trachomatis . This was a cross sectional study in 242 pregnant women aged ≥18 years attending their first ANC visit at Mbare polyclinic in Harare, Zimbabwe. Data collection form was used to obtain demographic and predisposing factors to Chlamydia infection and two endocervical swabs were collected from each patient. One specimen was examined by the POC test at the clinic and the other by SDA method in the laboratory. The sensitivity, specificity, positive and negative predictive values of the rapid kit were 71.4%, 99.6%, 90.9% and 98.3% respectively. Prevalence of C. trachomitis was 5.8% by SDA method. The kit's sensitivity (71.4%) and specificity (99.6%) implies that the rapid test is an important test which needs further evaluations. The prevalence of C. trichomitis of 5.8% is comparable to studies done elsewhere in Africa.
Teles, Fernando; Fonseca, Luís
2015-01-01
Accurate disease diagnosis in animals is crucial for animal well-being but also for preventing zoonosis transmission to humans. In particular, livestock diseases may constitute severe threats to humans due to the particularly high physical contact and exposure and, also, be the cause of important economic losses, even in non-endemic countries, where they often arise in the form of rapid and devastating epidemics. Rapid diagnostic tests have been used for a long time in field situations, particularly during outbreaks. However, they mostly rely on serological approaches, which may confirm the exposure to a particular pathogen but may be inappropriate for point-of-decision (point-of-care) settings when emergency responses supported on early and accurate diagnosis are required. Moreover, they often exhibit modest sensitivity and hence significantly depend on later result confirmation in central or reference laboratories. The impressive advances observed in recent years in materials sciences and in nanotechnology, as well as in nucleic-acid synthesis and engineering, have led to an outburst of new in-the-bench and prototype tests for nucleic-acid testing towards point-of-care diagnosis of genetic and infectious diseases. Manufacturing, commercial, regulatory, and technical nature issues for field applicability more likely have hindered their wider entrance into veterinary medicine and practice than have fundamental science gaps. This chapter begins by outlining the current situation, requirements, difficulties, and perspectives of point-of-care tests for diagnosing diseases of veterinary interest. Nucleic-acid testing, particularly for the point of care, is addressed subsequently. A range of valuable signal transduction mechanisms commonly employed in proof-of-concept schemes and techniques born on the analytical chemistry laboratories are also described. As the essential core of this chapter, sections dedicated to the principles and applications of microfluidics, lab
Point-of-care diagnostics: will the hurdles be overcome this time?
Huckle, David
2006-07-01
Point-of-care diagnostics have been proposed as the latest development in clinical diagnostics several times in the last 30 years; however, they have not yet fully developed into a business sector to match the projections. This perspective examines the reasons for past failures and the failure of technology to meet user needs. Advances have taken place in the last few years that effectively remove technology as a barrier to the development of point-of-care testing. Even regulatory issues regarding how products are developed and claims supported have been absorbed, understood and now accepted. The emphasis here is on the possible favorable aspects that are novel this time around. These changes have arisen as a result of the situation with global healthcare economics and the pressure from patients to be treated more like customers. The final hurdles relate to the conflict between diagnosis with the patient present and treated as soon as the point-of-care result is available and the entrenched positions of the central laboratory, the suppliers and their established distribution chains, and the way in which healthcare budgets are allocated. The ultimate hurdle that encapsulates all of these issues is reimbursement, which is the final barrier to a significant point-of-care diagnostics market--without reimbursement there will be no market.
Romoren, M; Hussein, F; Steen, T W; Velauthapillai, M; Sundby, J; Hjortdahl, P; Kristiansen, I S
2007-12-01
Chlamydia is the most common bacterial sexually transmitted infection worldwide and a major cause of morbidity-particularly among women and neonates. We compared costs and health consequences of using point-of-care (POC) tests with current syndromic management among antenatal care attendees in sub-Saharan Africa. We also compared erythromycin with azithromycin treatment and universal with age-based chlamydia management. A decision analytical model was developed to compare diagnostic and treatment strategies, using Botswana as a case. Model input was based upon (1) a study of pregnant women in Botswana, (2) literature reviews and (3) expert opinion. We expressed the study outcome in terms of costs (US$), cases cured, magnitude of overtreatment and successful partner treatment. Azithromycin was less costly and more effective than erythromycin. Compared with syndromic management, testing all attendees on their first visit with a 75% sensitive POC test increased the number of cases cured from 1500 to 3500 in a population of 100,000 women, at a cost of US$38 per additional case cured. This cost was lower in high-prevalence populations or if testing was restricted to teenagers. The specific POC tests provided the advantage of substantial reductions in overtreatment with antibiotics and improved partner management. Using POC tests to diagnose chlamydia during antenatal care in sub-Saharan Africa entails greater health benefits than syndromic management does-and at acceptable costs-especially when restricted to younger women. Changes in diagnostic strategy and treatment regimens may improve people's health and even reduce healthcare budgets.
Berg, Brandon; Cortazar, Bingen; Tseng, Derek; Ozkan, Haydar; Feng, Steve; Wei, Qingshan; Chan, Raymond Yan-Lok; Burbano, Jordi; Farooqui, Qamar; Lewinski, Michael; Di Carlo, Dino; Garner, Omai B; Ozcan, Aydogan
2015-08-25
Standard microplate based enzyme-linked immunosorbent assays (ELISA) are widely utilized for various nanomedicine, molecular sensing, and disease screening applications, and this multiwell plate batched analysis dramatically reduces diagnosis costs per patient compared to nonbatched or nonstandard tests. However, their use in resource-limited and field-settings is inhibited by the necessity for relatively large and expensive readout instruments. To mitigate this problem, we created a hand-held and cost-effective cellphone-based colorimetric microplate reader, which uses a 3D-printed opto-mechanical attachment to hold and illuminate a 96-well plate using a light-emitting-diode (LED) array. This LED light is transmitted through each well, and is then collected via 96 individual optical fibers. Captured images of this fiber-bundle are transmitted to our servers through a custom-designed app for processing using a machine learning algorithm, yielding diagnostic results, which are delivered to the user within ∼1 min per 96-well plate, and are visualized using the same app. We successfully tested this mobile platform in a clinical microbiology laboratory using FDA-approved mumps IgG, measles IgG, and herpes simplex virus IgG (HSV-1 and HSV-2) ELISA tests using a total of 567 and 571 patient samples for training and blind testing, respectively, and achieved an accuracy of 99.6%, 98.6%, 99.4%, and 99.4% for mumps, measles, HSV-1, and HSV-2 tests, respectively. This cost-effective and hand-held platform could assist health-care professionals to perform high-throughput disease screening or tracking of vaccination campaigns at the point-of-care, even in resource-poor and field-settings. Also, its intrinsic wireless connectivity can serve epidemiological studies, generating spatiotemporal maps of disease prevalence and immunity.
Apple, F S; Anderson, F P; Collinson, P; Jesse, R L; Kontos, M C; Levitt, M A; Miller, E A; Murakami, M M
2000-10-01
Validation of whole blood, point-of-care testing devices for monitoring cardiac markers to aid clinicians in ruling in and ruling out myocardial infarction (MI) is necessary for both laboratory and clinical acceptance. This study evaluated the clinical diagnostic sensitivity and specificity of the First Medical Cardiac Test device operated by nursing and laboratory personnel that simultaneously measures cardiac troponin I (cTnI), creatine kinase (CK) MB, myoglobin, and total CK on the Alpha Dx analyzer in whole blood for detection of MI. Over a 6-month period, 369 patients initially presenting to the emergency department with chest pain were evaluated for MI using modified WHO criteria. Eighty-nine patients (24%) were diagnosed with MI. In whole blood samples collected at admission and at 3- to 6-h intervals over 24 h, ROC curve-determined MI decision limits were as follows: cTnI, 0.4 microgram/L; CKMB, 7.0 microgram/L; myoglobin, 180 microgram/L; total CK, 190 microgram/L. Based on peak concentrations within 24 h after presentation, the following sensitivities (+/- 95% confidence intervals) were found: cTnI, 93% +/- 5.5%; myoglobin, 81% +/- 9.7%; CKMB, 90% +/- 6.3%; total CK, 86% +/- 7.5%. Sensitivities were maximal at >90% for both cTnI and CKMB at >12 h in MI patients, without differences between ST-segment elevation and non-ST-segment elevation MI patients. The First Medical point-of-care device provides cardiac marker assays that can be used by laboratories and clinicians in a variety of hospital settings for ruling in and ruling out MI.
Spaeth, Brooke A; Kaambwa, Billingsley; Shephard, Mark Ds; Omond, Rodney
2018-01-01
To determine the cost-effectiveness of utilizing point-of-care testing (POCT) on the Abbott i-STAT device as a support tool to aid decisions regarding the emergency medical retrievals of patients at remote health centers in the Northern Territory (NT) of Australia. A decision analytic simulation model-based economic evaluation was conducted using data from patients presenting with three common acute conditions (chest pain, chronic renal failure due to missed dialysis session(s), and acute diarrhea) at six remote NT health centers from July to December 2015. The specific outcomes measured in this study were the number of unnecessary emergency medical retrieval prevented through POCT. Cost savings through prevented unnecessary medical retrievals for each presentation type were then determined and extrapolated to give per annum NT-wide estimates. POCT prevented 60 unnecessary medical evacuations from a total of 200 patient cases meeting the selection criteria (48/147 for chest pain, 10/28 for missed dialysis, and 2/25 for acute diarrhea). The associated cost savings were AUD $4,674, $8,034, and $786 per patient translating to NT-wide savings of AUD $13.72 million, $6.45 million, and $1.57 million per annum (AUD $21.75 million in total) for chest pain, missed dialysis, and acute diarrhea presentations, respectively. This study demonstrated that POCT when used to aid decision making for acutely ill patients delivered significant cost savings for the NT health care system by preventing unnecessary emergency medical retrievals.
Wang, ShuQi; Zhao, Xiaohu; Khimji, Imran; Akbas, Ragip; Qiu, Weiliang; Edwards, Dale; Cramer, Daniel W.; Ye, Bin; Demirci, Utkan
2013-01-01
Ovarian cancer is asymptomatic at early stages and most patients present with advanced levels of disease. Lack of cost-effective methods that can achieve frequent, simple and non-invasive testing hinders early detection and causes high mortality in ovarian cancer patients. Here, we report a simple and inexpensive microchip ELISA-based detection module that employs a portable detection system, i.e., a cell phone/charge-coupled device (CCD) to quantify an ovarian cancer biomarker, HE4, in urine. Integration of a mobile application with a cell phone enabled immediate processing of microchip ELISA results, which eliminated the need for a bulky, expensive spectrophotometer. The HE4 level detected by a cell phone or a lensless CCD system was significantly elevated in urine samples from cancer patients (n = 19) than normal healthy controls (n = 20) (p < 0.001). Receiver operating characteristic (ROC) analyses showed that the microchip ELISA coupled with a cell phone running an automated analysis application had a sensitivity of 89.5% at a specificity of 90%. Under the same specificity, the microchip ELISA coupled with a CCD had a sensitivity of 84.2%. In conclusion, integration of microchip ELISA with cell phone/CCD-based colorimetric measurement technology can be used to detect HE4 biomarker at the point-of-care (POC), paving the way to create bedside technologies for diagnostics and treatment monitoring. PMID:21881677
Point-of-Care Diagnostics for Niche Applications
Cummins, Brian M.; Ligler, Frances S.; Walker, Glenn M.
2016-01-01
Point-of-care or point-of-use diagnostics are analytical devices that provide clinically relevant information without the need for a core clinical laboratory. In this review we define point-of-care diagnostics as portable versions of assays performed in a traditional clinical chemistry laboratory. This review discusses five areas relevant to human and animal health where increased attention could produce significant impact: veterinary medicine, space travel, sports medicine, emergency medicine, and operating room efficiency. For each of these areas, clinical need, available commercial products, and ongoing research into new devices are highlighted. PMID:26837054
Govindasamy, Darshini; Meghij, Jamilah; Negussi, Eyerusalem Kebede; Baggaley, Rachel Clare; Ford, Nathan; Kranzer, Katharina
2014-01-01
Introduction Several approaches have been taken to reduce pre-antiretroviral therapy (ART) losses between HIV testing and ART initiation in low- and middle-income countries, but a systematic assessment of the evidence has not yet been undertaken. The aim of this systematic review is to assess the potential for interventions to improve or facilitate linkage to or retention in pre-ART care and initiation of ART in low- and middle-income settings. Methods An electronic search was conducted on Medline, Embase, Global Health, Web of Science and conference databases to identify studies describing interventions aimed at improving linkage to or retention in pre-ART care or initiation of ART. Additional searches were conducted to identify on-going trials on this topic, and experts in the field were contacted. An assessment of the risk of bias was conducted. Interventions were categorized according to key domains in the existing literature. Results A total of 11,129 potentially relevant citations were identified, of which 24 were eligible for inclusion, with the majority (n=21) from sub-Saharan Africa. In addition, 15 on-going trials were identified. The most common interventions described under key domains included: health system interventions (i.e. integration in the setting of antenatal care); patient convenience and accessibility (i.e. point-of-care CD4 count (POC) testing with immediate results, home-based ART initiation); behaviour interventions and peer support (i.e. improved communication, patient referral and education) and incentives (i.e. food support). Several interventions showed favourable outcomes: integration of care and peer supporters increased enrolment into HIV care, medical incentives increased pre-ART retention, POC CD4 testing and food incentives increased completion of ART eligibility screening and ART initiation. Most studies focused on the general adult patient population or pregnant women. The majority of published studies were observational cohort
POC1A truncation mutation causes a ciliopathy in humans characterized by primordial dwarfism.
Shaheen, Ranad; Faqeih, Eissa; Shamseldin, Hanan E; Noche, Ramil R; Sunker, Asma; Alshammari, Muneera J; Al-Sheddi, Tarfa; Adly, Nouran; Al-Dosari, Mohammed S; Megason, Sean G; Al-Husain, Muneera; Al-Mohanna, Futwan; Alkuraya, Fowzan S
2012-08-10
Primordial dwarfism (PD) is a phenotype characterized by profound growth retardation that is prenatal in onset. Significant strides have been made in the last few years toward improved understanding of the molecular underpinning of the limited growth that characterizes the embryonic and postnatal development of PD individuals. These include impaired mitotic mechanics, abnormal IGF2 expression, perturbed DNA-damage response, defective spliceosomal machinery, and abnormal replication licensing. In three families affected by a distinct form of PD, we identified a founder truncating mutation in POC1A. This gene is one of two vertebrate paralogs of POC1, which encodes one of the most abundant proteins in the Chlamydomonas centriole proteome. Cells derived from the index individual have abnormal mitotic mechanics with multipolar spindles, in addition to clearly impaired ciliogenesis. siRNA knockdown of POC1A in fibroblast cells recapitulates this ciliogenesis defect. Our findings highlight a human ciliopathy syndrome caused by deficiency of a major centriolar protein. Copyright © 2012 The American Society of Human Genetics. Published by Elsevier Inc. All rights reserved.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-12-06
...This is notice, in accordance with 35 U.S.C. 209 and 37 CFR Part 404, that the National Institutes of Health, Department of Health and Human Services, is contemplating the grant of an exclusive patent license to practice the inventions embodied in the following U.S. Patents and Patent Applications to Beacon Biomedical LLC (``Beacon'') located in Scottsdale, AZ, USA.
Comparison of three point-of-care blood glucose meters for use in adult and juvenile alpacas.
Tennent-Brown, Brett S; Koenig, Amie; Williamson, Lisa H; Boston, Raymond C
2011-08-01
To compare the performance of 3 point-of-care glucose meters in adult and juvenile alpacas with that of a laboratory-based analyzer. Evaluation study. 35 adult alpacas and 21 juvenile alpacas. Whole blood samples obtained via jugular venipuncture were tested with all 3 point-of-care glucose meters; plasma samples were also tested with 1 of those meters. Glucose concentrations determined by use of the point-of-care meters were compared with results from the laboratory-based analyzer. Plasma glucose concentrations determined by use of the laboratory-based analyzer ranged from 36 to 693 mg/dL. Over the entire range of glucose concentrations tested, the Lin concordance correlation coefficient (agreement) was significant and excellent for all comparisons. Concordance decreased for 1 glucometer when testing whole blood samples over a narrower range of glucose concentrations (50 to 200 mg/dL). Bias was typically small (< 10 mg/dL) for 3 of the 4 comparisons but considerable for 1 meter with the use of whole blood. The limits of agreement were wide for all comparisons over the entire range of glucose concentrations tested but decreased to within acceptable limits when the narrower glucose range (50 to 200 mg/dL) was analyzed for 3 of the comparisons. For samples with a PCV < 25%, bias and the limits of agreement were greater for one of the meters tested. Discrepancies between point-of-care glucose meters and reference techniques can be considerable in alpacas, emphasizing the importance of assessing individual meter performance in a target population.
Human anti-HIV IgM detection by the OraQuick ADVANCE® Rapid HIV 1/2 Antibody Test.
Guillon, Geraldine; Yearwood, Graham; Snipes, Casey; Boschi, Daniel; Reed, Michael R
2018-01-01
The Centers for Disease Control and Prevention (CDC) and many public health jurisdictions continue to advocate for the most sensitive rapid HIV test that is available. Currently, the recommendation is to utilize tests that can detect HIV infection biomarkers within 30 days of infection, when initial immune responses are mounted. The infected patient's IgM response is often used to detect acute infection within a 20-25 days window after infection. This requirement applies to lab-based testing with automated analyzers and rapid, point of care (POC) testing used for screening in a non-clinical setting. A recent study has demonstrated that POC tests using a Protein A-based detection system can detect samples with predominantly HIV-1 IgM reactivity (Moshgabadi et al., 2015). The OraQuick ADVANCE ® Rapid HIV-1/2 Antibody Test (OraQuick ADVANCE ®) also uses Protein A as the detection protein in the antibody-binding colloidal gold conjugate, so it is expected that the OraQuick ADVANCE ® Test will also detect samples with predominantly IgM reactivity. This report definitively demonstrates that the OraQuick ADVANCE ® Test can detect IgM antibodies during an acute infection window period of approximately 20-25 days after infection, and is therefore suitable for use in testing environments requiring adherence to current CDC recommendations.
Point-of-care diagnostics for niche applications.
Cummins, Brian M; Ligler, Frances S; Walker, Glenn M
2016-01-01
Point-of-care or point-of-use diagnostics are analytical devices that provide clinically relevant information without the need for a core clinical laboratory. In this review we define point-of-care diagnostics as portable versions of assays performed in a traditional clinical chemistry laboratory. This review discusses five areas relevant to human and animal health where increased attention could produce significant impact: veterinary medicine, space travel, sports medicine, emergency medicine, and operating room efficiency. For each of these areas, clinical need, available commercial products, and ongoing research into new devices are highlighted. Copyright © 2016 Elsevier Inc. All rights reserved.
Pai, Nitika Pant; Dhurat, Rachita; Potter, Martin; Behlim, Tarannum; Landry, Geneviève; Vadnais, Caroline; Rodrigues, Camilla; Joseph, Lawrence; Shetty, Anjali
2014-01-01
Objectives Multiplexed point-of-care (POC) devices can rapidly screen for HIV-related co-infections (eg, hepatitis C (HCV), hepatitis B (HBV), syphilis) in one patient visit, but global evidence for this approach remains limited. This study aimed to evaluate a multiplex POC testing strategy to expedite screening for HIV-related co-infections in at-risk populations. Methods A multiplex strategy was developed with two subsequent versions of an investigational device Miriad. It was evaluated in two non-comparable settings and populations in two countries for feasibility of conduct, detection of new infections, preference and accuracy. Version 1 was evaluated in 375 sexually transmitted disease clinic attendees in Mumbai, India; version 2 was evaluated in 119 injection drug users in Montreal, Canada. Results Feasibility (completion rate) of the multiplex strategy was high (86.1% Mumbai; 92.4% Montreal). A total of 170 new infections were detected in Mumbai (56 HIV, 75 HBV, 37 syphilis, 2 HCV) versus 2 in Montreal. Preference was 60% in Mumbai and 97% in Montreal. Miriad version 1 specificities were high: HIV 99.7% (98.3% to 100%), HBV 99.3% (97.6% to 99.9%), HCV 99.7% (98.5% to 99.9%), syphilis 85.2% (80.9% to 88.8%); sensitivities were as follows: HIV 100% (94.8% to 100%), HBV 13.3% (6.6% to 23.2%), HCV 50% (1.3% to 98.7%), syphilis 86.1% (70.5% to 95.3%). With version 2, specificities improved: HIV 100% (97.2% to 100%), HBV 100% (97.3% to 100%), HCV 85.3% (73.8% to 93.0%), syphilis 98.1% (93.3% to 99.8%); sensitivities were: HIV 100% (47.3% to 100%), HCV 80.4% (66.1% to 90.6%), syphilis 100% (22.4% to 100%). Conclusions A quad multiplex POC strategy for HIV and co-infections was feasible to operationalise and preferred by patients in both settings. Many new infections were identified in Mumbai and accuracy improved with version 2 of the assay. Such a strategy will help expedite screening for co-infections, particularly where baseline screening is low. These findings
Toskin, Igor; Murtagh, Maurine; Peeling, Rosanna W; Blondeel, Karel; Cordero, Joanna; Kiarie, James
2017-12-01
Advancing the field of point-of-care testing (POCT) for STIs can rapidly and substantially improve STI control and prevention by providing targeted, essential STI services (case detection and screening). POCT enables definitive diagnosis and appropriate treatment in a single visit and home and community-based testing. Since 2014, the WHO Department of Reproductive Health and Research, in collaboration with technical partners, has completed four landscape analyses of promising diagnostics for use at or near the point of patient care to detect syphilis, Neisseria gonorrhoeae , Chlamydia trachomatis , Trichomonas vaginalis and the human papillomavirus. The analyses comprised a literature review and interviews. Two International Technical Consultations on STI POCTs (2014 and 2015) resulted in the development of target product profiles (TPP). Experts in STI microbiology, laboratory diagnostics, clinical management, public health and epidemiology participated in the consultations with representation from all WHO regions. The landscape analysis identified diagnostic tests that are either available on the market, to be released in the near future or in the pipeline. The TPPs specify 28 analytical and operational characteristics of POCTs for use in different populations for surveillance, screening and case management. None of the tests that were identified in the landscape analysis met all of the targets of the TPPs. More efforts of the global health community are needed to accelerate access to affordable quality-assured STI POCTs, particularly in low- and middle-income countries, by supporting the development of new diagnostic platforms as well as strengthening the validation and implementation of existing diagnostics according to internationally endorsed standards and the best available evidence. © World Health Organization 2017. Licensee BMJ Publishing Group Limited. This is an open access article distributed under the terms of the Creative Commons Attribution IGO
NASA Astrophysics Data System (ADS)
Han, Sungyub; Locke, Andrea K.; Oaks, Luke A.; Cheng, Yi-Shing Lisa; Coté, Gerard L.
2018-02-01
It is estimated that the number of new cases of oral cancers worldwide is 529,000 and more than 300,000 deaths each year. The five-year survival rate remains about 50%, and the low survival rate is believed to be due to delayed detection. The primary detection method is through a comprehensive clinical examination by a dentist followed by a biopsy of suspicious lesions. Systematic review and meta-analysis have revealed that clinical examination alone may not be sufficient to cause the clinician to perform a biopsy or refer for biopsy for early detection of OSCC. Therefore, a non-invasive, point-of-Care (POC) detection with high sensitivity and specificity for early detection would be urgently needed, and using salivary biomarkers would be an ideal technology for it. S100 calcium binding protein P (S100P) mRNA presenting in saliva is a potential biomarker for detection of oral cancer. Further, surface enhanced Raman spectroscopy (SERS) has been shown to be a promising POC diagnostic technique. In this research, a SERS-based assay using oligonucleotide strains was developed for the sensitive and rapid detection of S100P. Gold nanoparticles (AuNPs) as a SERS substrate were used for the conjugation with one of two unique 24 base pair oligonucleotides, referred to as left and right DNA probes. A Raman reporter molecule, malachite green isothiocyanate (MGITC), was bound to left-probe-conjugated AuNPs. UV-vis spectroscopy was employed to monitor the conjugation of DNA probes to AuNPs. The hybridization of S100P target to DNA-conjugated AuNPs in sandwich-assay format was confirmed by Raman spectroscopy and shown to yield and R2 of 0.917 across the range of 0-200 nM and a limit of detection of 3 nM.
A smartphone-based system for the automated management of point-of-care test results in hospitals.
Jang, Dasom; Shin, Soo-Yong; Seo, Dong-Woo; Joo, Segyeong; Huh, Soo-Jin
2015-04-01
Managing test results is an important issue in hospitals because of the increasing use of point-of-care testing (POCT). Here, we propose a smartphone-based system for automatically managing POCT test results. We developed the system to provide convenience to the medical staffs. The system recognizes the patient identification or prescription number of the test by reading barcodes and provides a countdown to indicate when the results will be ready. When the countdown in finished, a picture of the test result is transferred to the electronic medical record server using the Health Level 7 protocol. Human immunodeficiency virus (HIV) kits were selected in this research because HIV is a life-threatening infectious virus, especially for the medical staff who treat undiagnosed patients. The performance of the system was verified from a survey of the users. The performance of the system was tested at the emergency room (ER) for 10 months using commercially available POCT kits for detecting HIV. The survey showed that, in total, 80% and 0% of users reported positive or negative feedback, respectively. The staff also reported that the system reduced total processing time by approximately 32 min, in addition to reducing workload. The developed automated management system was successfully tested at an ER for 10 months. The survey results show that the system is effective and that medical staff members who used the system are satisfied with using the system at the ER.
NASA Astrophysics Data System (ADS)
Lyu, Heng; Wang, Yannan; Jin, Qi; Shi, Lei; Li, Yunmei; Wang, Qiao
2017-10-01
Particulate organic carbon (POC) plays an important role in the carbon cycle in water due to its biological pump process. In the open ocean, algorithms can accurately estimate the surface POC concentration. However, no suitable POC-estimation algorithm based on MERIS bands is available for inland turbid eutrophic water. A total of 228 field samples were collected from Lake Taihu in different seasons between 2013 and 2015. At each site, the optical parameters and water quality were analyzed. Using in situ data, it was found that POC-estimation algorithms developed for the open ocean and coastal waters using remote sensing reflectance were not suitable for inland turbid eutrophic water. The organic suspended matter (OSM) concentration was found to be the best indicator of the POC concentration, and POC has an exponential relationship with the OSM concentration. Through an analysis of the POC concentration and optical parameters, it was found that the absorption peak of total suspended matter (TSM) at 665 nm was the optimum parameter to estimate POC. As a result, MERIS band 7, MERIS band 10 and MERIS band 12 were used to derive the absorption coefficient of TSM at 665 nm, and then, a semi-analytical algorithm was used to estimate the POC concentration for inland turbid eutrophic water. An accuracy assessment showed that the developed semi-analytical algorithm could be successfully applied with a MAPE of 31.82% and RMSE of 2.68 mg/L. The developed algorithm was successfully applied to a MERIS image, and two full-resolution MERIS images, acquired on August 13, 2010, and December 7, 2010, were used to map the POC spatial distribution in Lake Taihu in summer and winter.
Siersma, Volkert; Kousgaard, Marius Brostrøm; Reventlow, Susanne; Ertmann, Ruth; Felding, Peter; Waldorff, Frans Boch
2015-02-01
This study aimed to evaluate the relative effectiveness of electronic and postal reminders for increasing adherence to the quality assurance programme for the international normalized ratio (INR) point-of-care testing (POCT) device in primary care. All 213 family practices that use the Elective Laboratory of the Capital Region, Denmark, and regularly conduct INR POCT were randomly allocated into two similarly sized groups. During the 4-month intervention, these practices were sent either computer reminders (ComRem) or computer-generated postal reminders (Postal) if they did not perform a split test to check the quality of their INR POCT for each calendar month. The adherence of the practices was tracked during the subsequent 8 months subdivided into two 4-month periods both without intervention. Outcomes were measures of split test procedure adherence. Both interventions were associated with an increase in adherence to the split test procedure - a factor 6.00 [95% confidence interval (CI) 4.46-7.72] and 8.22 [95% CI 5.87-11.52] for ComRem and Postal, respectively - but there is no evidence that one of the interventions was more effective than the other. In the ComRem group, the expected number of split tests (out of four) was 2.54 (95% CI 2.33-2.76) versus 2.44 (95% CI 2.24-2.65) in the Postal group, P = 0.14. There was a slight decrease in adherence over the two follow-ups, but neither intervention was better than the other in achieving a lasting improvement in adherence. Computer reminders are as efficient as postal reminders in increasing adherence to a quality assurance programme for the INR POCT device in primary care. © 2014 John Wiley & Sons, Ltd.
Rennert, Hanna; Eng, Kenneth; Zhang, Tuo; Tan, Adrian; Xiang, Jenny; Romanel, Alessandro; Kim, Robert; Tam, Wayne; Liu, Yen-Chun; Bhinder, Bhavneet; Cyrta, Joanna; Beltran, Himisha; Robinson, Brian; Mosquera, Juan Miguel; Fernandes, Helen; Demichelis, Francesca; Sboner, Andrea; Kluk, Michael; Rubin, Mark A; Elemento, Olivier
2016-01-01
We describe Exome Cancer Test v1.0 (EXaCT-1), the first New York State-Department of Health-approved whole-exome sequencing (WES)-based test for precision cancer care. EXaCT-1 uses HaloPlex (Agilent) target enrichment followed by next-generation sequencing (Illumina) of tumour and matched constitutional control DNA. We present a detailed clinical development and validation pipeline suitable for simultaneous detection of somatic point/indel mutations and copy-number alterations (CNAs). A computational framework for data analysis, reporting and sign-out is also presented. For the validation, we tested EXaCT-1 on 57 tumours covering five distinct clinically relevant mutations. Results demonstrated elevated and uniform coverage compatible with clinical testing as well as complete concordance in variant quality metrics between formalin-fixed paraffin embedded and fresh-frozen tumours. Extensive sensitivity studies identified limits of detection threshold for point/indel mutations and CNAs. Prospective analysis of 337 cancer cases revealed mutations in clinically relevant genes in 82% of tumours, demonstrating that EXaCT-1 is an accurate and sensitive method for identifying actionable mutations, with reasonable costs and time, greatly expanding its utility for advanced cancer care. PMID:28781886
Hohmeier, Kenneth C; McDonough, Sharon L K; Wang, Junling
Point-of-care testing (POCT) is a specialty of laboratory medicine that occurs at the bedside or near the patient when receiving health services. Despite its established clinical utility and consumer demand in the community pharmacy, the implementation of POCT within this setting has remained modest for a variety of reasons. One possible solution to this problem is the concept of co-creation - the partnership between consumer and manufacturer in the development of value for a service or device. Using the theoretical underpinning of co-creation, this study aimed to investigate perceptions of point-of-care-testing (POCT) industry leadership on the community pharmacy market in the United States to uncover reasons for limited implementation within community pharmacies. Participants were recruited for this study through the use of snowball sampling. A series of semi-structured interviews were conducted with the participants via telephone. Interviews were recorded, transcribed, and entered into a qualitative analysis software program to summarize the data. Five key themes were uncovered: gaps in understanding, areas of positive impact, barriers to implementation, facilitators of implementation, and community pharmacy - a potential major player. Through uncovering gaps in perceptions, it may be possible to leverage the U.S. pharmacy industry's size, potential for scalability, and ease of patient access to further patient care. Copyright © 2016 Elsevier Inc. All rights reserved.
Hashem, Ahmad; Ruggeri, Roberto
2003-01-01
Creating an integration-friendly infrastructure is the best way to prepare for current as well as next-generation POC devices. Fortunately, hassle-free system integration is needed throughout healthcare today for reasons beyond the domain of POC devices, so integration progress already made in other areas helps pave the way for POC devices. Healthcare IT professionals, as much or more than any other IT group, have had to deal with the challenges of integrating disparate systems. When considering deployment of POC devices, you will want to make sure they adhere to open industry standards. In this way, these important devices won't add to the problem of disparate systems, but will contribute to the solution. We see XML and Web services as being especially important to the future of healthcare delivery and administration. XML and Web services, along with powerful orchestrators, can provide an ever-richer collection of clinical data to be delivered to, and received from, the POC devices that will become an ever more important addition to the physician armamentarium.
Marine boundary layer cloud regimes and POC formation in an LES coupled to a bulk aerosol scheme
NASA Astrophysics Data System (ADS)
Berner, A. H.; Bretherton, C. S.; Wood, R.; Muhlbauer, A.
2013-07-01
A large-eddy simulation (LES) coupled to a new bulk aerosol scheme is used to study long-lived regimes of aerosol-boundary layer cloud-precipitation interaction and the development of pockets of open cells (POCs) in subtropical stratocumulus cloud layers. The aerosol scheme prognoses mass and number concentration of a single log-normal accumulation mode with surface and entrainment sources, evolving subject to processing of activated aerosol and scavenging of dry aerosol by cloud and rain. The LES with the aerosol scheme is applied to a range of steadily-forced simulations idealized from a well-observed POC case. The long-term system evolution is explored with extended two-dimensional simulations of up to 20 days, mostly with diurnally-averaged insolation. One three-dimensional two-day simulation confirms the initial development of the corresponding two-dimensional case. With weak mean subsidence, an initially aerosol-rich mixed layer deepens, the capping stratocumulus cloud slowly thickens and increasingly depletes aerosol via precipitation accretion, then the boundary layer transitions within a few hours into an open-cell regime with scattered precipitating cumuli, in which entrainment is much weaker. The inversion slowly collapses for several days until the cumulus clouds are too shallow to efficiently precipitate. Inversion cloud then reforms and radiatively drives renewed entrainment, allowing the boundary layer to deepen and become more aerosol-rich, until the stratocumulus layer thickens enough to undergo another cycle of open-cell formation. If mean subsidence is stronger, the stratocumulus never thickens enough to initiate drizzle and settles into a steady state. With lower initial aerosol concentrations, this system quickly transitions into open cells, collapses, and redevelops into a different steady state with a shallow, optically thin cloud layer. In these steady states, interstitial scavenging by cloud droplets is the main sink of aerosol number. The
Knapp, Herschel; Chan, Kee; Anaya, Henry D; Goetz, Matthew B
2011-06-01
We successfully created and implemented an effective HIV rapid testing training and certification curriculum using traditional in-person training at multiple sites within the U.S. Department of Veterans Affairs (VA) Healthcare System. Considering the multitude of geographically remote facilities in the nationwide VA system, coupled with the expansion of HIV diagnostics, we developed an alternate training method that is affordable, efficient, and effective. Using materials initially developed for in-person HIV rapid test in-services, we used a distance learning model to offer this training via live audiovisual online technology to educate clinicians at a remote outpatient primary care VA facility. Participants' evaluation metrics showed that this form of remote education is equivalent to in-person training; additionally, HIV testing rates increased considerably in the months following this intervention. Although there is a one-time setup cost associated with this remote training protocol, there is potential cost savings associated with the point-of-care nurse manager's time productivity by using the Internet in-service learning module for teaching HIV rapid testing. If additional in-service training modules are developed into Internet-based format, there is the potential for additional cost savings. Our cost analysis demonstrates that the remote in-service method provides a more affordable and efficient alternative compared with in-person training. The online in-service provided training that was equivalent to in-person sessions based on first-hand supervisor observation, participant satisfaction surveys, and follow-up results. This method saves time and money, requires fewer personnel, and affords access to expert trainers regardless of geographic location. Further, it is generalizable to training beyond HIV rapid testing. Based on these consistent implementation successes, we plan to expand use of online training to include remote VA satellite facilities spanning
Litster, A L; Pressler, B; Volpe, A; Dubovi, E
2012-08-01
Canine parvovirus (CPV) and canine distemper virus (CDV) are highly infectious and often fatal diseases with worldwide distributions, and are important population management considerations in animal shelters. A point-of-care ELISA test kit is available to detect serum antibodies to CPV and CDV, and presumptively to predict protective status. The aim of this study was to determine the diagnostic accuracy of the test compared to CPV hemagglutination inhibition titers and CDV serum neutralization titers determined by a reference laboratory, using sera collected from dogs housed at animal shelters. The ELISA test was used under both field and laboratory conditions and duplicate specimens were processed using an extra wash step. The test kit yielded accurate results (CPV: sensitivity 92.3%, specificity 93.5%; CDV: sensitivity 75.7%, specificity 91.8%) under field conditions. CDV sensitivity was improved by performing the test under laboratory conditions and using an optical density (OD) meter (laboratory performed 94.0%; OD 88.1%). Point-of-care ELISA testing for serum CPV and CDV antibody titers was demonstrated to be a useful tool for determining antibody status when making decisions regarding the need for CPV and/or CDV vaccination and also in animal shelters for population management. Copyright © 2012 Elsevier Ltd. All rights reserved.
Electrochemical K-562 cells sensor based on origami paper device for point-of-care testing.
Ge, Shenguang; Zhang, Lina; Zhang, Yan; Liu, Haiyun; Huang, Jiadong; Yan, Mei; Yu, Jinghua
2015-12-01
A low-cost, simple, portable and sensitive paper-based electrochemical sensor was established for the detection of K-562 cell in point-of-care testing. The hybrid material of 3D Au nanoparticles/graphene (3D Au NPs/GN) with high specific surface area and ionic liquid (IL) with widened electrochemical windows improved the good biocompatibility and high conductivity was modified on paper working electrode (PWE) by the classic assembly method and then employed as the sensing surface. IL could not only enhance the electron transfer ability but also provide sensing recognition interface for the conjugation of Con A with cells, with the cell capture efficiency and the sensitivity of biosensor strengthened simultaneously. Concanavalin A (Con A) immobilization matrix was used to capture cells. As proof-of-concept, the paper-based electrochemical sensor for the detection of K-562 cells was developed. With such sandwich-type assay format, K-562 cells as model cells were captured on the surface of Con A/IL/3D AuNPs@GN/PWE. Con A-labeled dendritic PdAg NPs were captured on the surface of K-562 cells. Such dendritic PdAg NPs worked as catalysts promoting the oxidation of thionine (TH) by H2O2 which was released from K-562 cells via the stimulation of phorbol 12-myristate-13-acetate (PMA). Therefore, the current signal response was dependent on the amount of PdAg NPs and the concentration of H2O2, the latter of which corresponded with the releasing amount from cells. So, the detection method of K-562 cell was also developed. Under optimized experimental conditions, 1.5×10(-14) mol of H2O2 releasing from each cell was calculated. The linear range and the detection limit for K-562 cells were determined to be 1.0×10(3)-5.0×10(6) cells/mL and 200 cells/mL, respectively. Such as-prepared sensor showed excellent analytical performance with good fabrication reproducibility, acceptable precision and satisfied accuracy, providing a novel protocol in point-of-care testing of cells
Brimelow, Rachel E; Gibney, Annie; Meakin, Suzanne; Wollin, Judy A
2017-04-01
Continued development of mobile technology now allows access to information at the point-of-care. This study was conducted to evaluate the use of one such tool on a mobile device, from the carer perspective. Caregivers across 12 aged-care facilities were supplied mobile devices to access a Picture Care Plan (PCP), a specific tool designed around the role of the personal carer. An anonymous questionnaire was subsequently completed by 85 carers with questions relating to participants' experience. Perceived helpfulness of the PCP at the point-of-care was high (87%). A significant number of participants believed the use of the PCP increased resident safety and quality of care (76%). Practical components related to the carrying of the device, network speed and the requirement to maintain communication with senior members of staff to ascertain updates were also expressed by participants. Findings suggest that staff are receptive to adoption of mobile devices to access care directives at the point-of-care and that the technology is useful.
Metcalfe, Michael J; Petros, Firas G; Rao, Priya; Mork, Maureen E; Xiao, Lianchun; Broaddus, Russell R; Matin, Surena F
2018-01-01
Patients with Lynch syndrome are at risk for upper tract urothelial carcinoma. We sought to identify the incidence and most reliable means of point of care screening for Lynch syndrome in patients with upper tract urothelial carcinoma. A total of 115 consecutive patients with upper tract urothelial carcinoma without a history of Lynch syndrome were universally screened during followup from January 2013 through July 2016. We evaluated patient and family history using AMS (Amsterdam criteria) I and II, and tumor immunohistochemistry for mismatch repair proteins and microsatellite instability. Patients who were positive for AMS I/II, microsatellite instability or immunohistochemistry were classified as potentially having Lynch syndrome and referred for clinical genetic analysis and counseling. Patients with known Lynch syndrome served as positive controls. Of the 115 patients 16 (13.9%) screened positive for potential Lynch syndrome. Of these patients 7.0% met AMS II criteria, 11.3% had loss of at least 1 mismatch repair protein and 6.0% had high microsatellite instability. All 16 patients were referred for germline testing, 9 completed genetic analysis and counseling, and 6 were confirmed to have Lynch syndrome. All 7 patients with upper tract urothelial carcinoma who had a known history of Lynch syndrome were positive for AMS II criteria and at least a single mismatch repair protein loss while 5 of 6 had high microsatellite instability. We identified 13.9% of upper tract urothelial carcinoma cases as potential Lynch syndrome and 5.2% as confirmed Lynch syndrome at the point of care. These findings have important implications for universal screening of upper tract urothelial carcinoma, representing one of the highest rates of undiagnosed genetic disease in a urological cancer. Copyright © 2018 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.
Badman, Steven G; Vallely, Lisa M; Toliman, Pamela; Kariwiga, Grace; Lote, Bomesina; Pomat, William; Holmer, Caroline; Guy, Rebecca; Luchters, Stanley; Morgan, Chris; Garland, Suzanne M; Tabrizi, Sepehr; Whiley, David; Rogerson, Stephen J; Mola, Glen; Wand, Handan; Donovan, Basil; Causer, Louise; Kaldor, John; Vallely, Andrew
2016-06-06
Sexually transmitted and genital infections in pregnancy are associated with an increased risk of adverse maternal and neonatal health outcomes. High prevalences of sexually transmitted infections have been identified among antenatal attenders in Papua New Guinea. Papua New Guinea has amongst the highest neonatal mortality rates worldwide, with preterm birth and low birth weight major contributors to neonatal mortality. The overall aim of our study was to determine if a novel point-of-care testing and treatment strategy for the sexually transmitted and genital infections Chlamydia trachomatis (CT), Neisseria gonorrhoeae (NG), Trichomonas vaginalis (TV) and Bacterial vaginosis (BV) in pregnancy is feasible in the high-burden, low-income setting of Papua New Guinea. Women attending their first antenatal clinic visit were invited to participate. CT/NG and TV were tested using the GeneXpert platform (Cepheid, USA), and BV tested using BVBlue (Gryphus Diagnostics, USA). Participants received same-day test results and antibiotic treatment as indicated. Routine antenatal care including HIV and syphilis screening were provided. Point-of-care testing was provided to 125/222 (56 %) of women attending routine antenatal care during the three-month study period. Among the 125 women enrolled, the prevalence of CT was 20.0 %; NG, 11.2 %; TV, 37.6 %; and BV, 17.6 %. Over half (67/125, 53.6 %) of women had one or more of these infections. Most women were asymptomatic (71.6 %; 47/67). Women aged 24 years and under were more likely to have one or more STI compared with older women (odds ratio 2.38; 95 % CI: 1.09, 5.21). Most women with an STI received treatment on the same day (83.6 %; 56/67). HIV prevalence was 1.6 % and active syphilis 4.0 %. Point-of-care STI testing and treatment using a combination of novel, newly-available assays was feasible during routine antenatal care in this setting. This strategy has not previously been evaluated in any setting and offers the
Stephen, Stephen; Muchaneta-Kubara, Chiwoneso Gwyneth Elizabeth; Munjoma, Marshall Wesley; Mandozana, Gibson
2017-01-01
Background: Cervical chlamydia infection poses high risk of pregnancy complications and neonatal infection. Reference methods for the detection of chlamydia infection are not available for routine use in developing countries. Point-of-care (POC) tests can bridge this gap. This study evaluated Cortez Onestep Chlamydia Rapicard™ insta test for the detection of Chlamydia trachomatis in pregnant women at Mbare Polyclinic and determined the prevalence of C. trachomatis. Methods: This was a cross sectional study in 242 pregnant women aged ≥18 years attending their first ANC visit at Mbare polyclinic in Harare, Zimbabwe. Data collection form was used to obtain demographic and predisposing factors to Chlamydia infection and two endocervical swabs were collected from each patient. One specimen was examined by the POC test at the clinic and the other by SDA method in the laboratory. Results: The sensitivity, specificity, positive and negative predictive values of the rapid kit were 71.4%, 99.6%, 90.9% and 98.3% respectively. Prevalence of C. trachomitis was 5.8% by SDA method. Conclusion and Global Health Implications: The kit’s sensitivity (71.4%) and specificity (99.6%) implies that the rapid test is an important test which needs further evaluations. The prevalence of C. trichomitis of 5.8% is comparable to studies done elsewhere in Africa. PMID:28798890
Mata, Verónica Elizabeth; Passos, Sonia Regina Lambert; Hökerberg, Yara Hahr Marques; Berardinelli, Guilherme Miguéis; Dos Santos, Maria Angelica Borges; Fukuoka, Levy Vilas Boas; Maciel, Anna Carolina Fontoura Seixas Rangel; Dos Santos Rodrigues, Cintia Damasceno; da Silva Santos, Aline; de Vasconcellos Carvalhaes de Oliveira, Raquel
2017-08-29
Rapid immunochromatographic tests (ICT) for dengue non-structural protein 1 (NS1) have shown good performance for diagnosing acute-phase dengue in serum in laboratory settings, but rarely have been assessed in whole blood and at point of care (POC). This study compare the accuracy and inter- and intra-observer reliability of the NS1 Bioeasy™ ICT in whole blood at POC versus serum in the laboratory, during a DENV-1 epidemic. Cross-sectional study involving 144 adults spontaneously demanding care in an emergency department within 4 days of onset of acute febrile illness. Accuracy of NS1 Bioeasy™ ICT was compared in whole blood and serum, both at 15 and 30 min, blinded to the reference RT-PCR or NS1 ELISA. Non-dengue patients were also tested for Zika virus with RT-PCR. Reliability of whole blood and serum readings by the same or different observers was measured by simple kappa (95% CI). At 15 min, sensitivity (Sn) of NS1 Bioeasy™ ICT in whole blood/POC was 76.7% (95% CI: 68.0-84.1) and specificity (Sp) was 87.0% (95% CI: 66.4-97.2). Sn in serum/laboratory was 82% (95% CI: 74.1-88.6) and Sp 100% (95% CI: 85.8-100). Positive likelihood ratio was 5.9 (95% CI: 2.0-17.0) for whole blood/POC and 19.8 (95% CI: 2.9-135.1) for serum/laboratory. Reliability of matched readings of whole blood/POC and serum/laboratory by the same observer (k = 0.83, 95% CI: 0.74-0.93) or different observers (k = 0.81, 95% CI: 0.72-0.92) was almost perfect, with higher discordant levels in the absence of dengue. Results did not differ statistically at 5%. NS1 Bioeasy™ ICT in DENV-1 epidemics is a potentially confirmatory test. Invalid results at 15 min should be reread at 30 min. To optimize impact of implementing ICT in the management of false-negatives it should be incorporated into an algorithm according to setting and available specimen. UTN U1111-1145-9451 .
Gupta, Ekta; Agarwala, Pragya; Kumar, Guresh; Maiwall, Rakhi; Sarin, Shiv Kumar
2017-03-01
Molecular testing at the point-of-care may turn out to be game changer for HCV diagnosis and treatment monitoring, through increased sensitivity, reduced turnaround time, and ease of performance. One such assay GeneXpert ® has recently been released. Comparative analysis between performances of GeneXpert ® and Abbott HCV-RNA was done. 174 HCV infected patients were recruited and, one time plasma samples from 154 patients and repeated samples from 20 patients, obtained at specific treatment time-points (0, 4, 12 and 24) weeks were serially re-tested on Xpert ® . Genotype 3 was the commonest, seen in 80 (66%) of the cases, genotype 1 in 34 (28.3%), genotype 4 in 4 (3.3%) and genotypes 2 and 5 in 1 (0.8%) each. Median HCV RNA load was 4.69 log 10 (range: 0-6.98log 10 ) IU/ml. Overall a very good correlation was seen between the two assays (R 2 =0.985), concordance of the results between the assays was seen in 138 samples (89.6%). High and low positive standards were tested ten times on Xpert ® to evaluate the precision and the coefficient of variation was 0.01 for HPC and 0.07 for the LPC. Monitoring of patients on two different regimes of treatment, pegylated interferon plus ribavirin and sofosbuvir plus ribavirin was done by both the systems at baseline, 4, 12 and 24 weeks. Perfect correlation between the assays in the course of therapy at different treatment time- point in genotypes 3 and 1 was seen. The study demonstrates excellent performance of the Xpert ® HCV assay in viral load assessment and in treatment course monitoring consistency. Copyright © 2017 Elsevier B.V. All rights reserved.
Shadfan, Basil H.; Simmons, Archana R.; Simmons, Glennon W.; Ho, Andy; Wong, Jorge; Lu, Karen H.; Bast, Robert C.; McDevitt, John T.
2015-01-01
Point-of-care (POC) diagnostic platforms have the potential to enable low-cost, large-scale screening. As no single biomarker is shed by all ovarian cancers, multiplexed biomarker panels promise improved sensitivity and specificity to address the unmet need for early detection of ovarian cancer. We have configured the programmable bio-nano-chip (p-BNC) - a multiplexable, microfluidic, modular platform - to quantify a novel multimarker panel comprising CA125, HE4, MMP-7 and CA72-4. The p-BNC is a bead-based immunoanalyzer system with a credit-card-sized footprint that integrates automated sample metering, bubble and debris removal, reagent storage and waste disposal, permitting POC analysis. Multiplexed p-BNC immunoassays demonstrated high specificity, low cross-reactivity, low limits of detection suitable for early detection, and a short analysis time of 43 minutes. Day-to-day variability, a critical factor for longitudinally monitoring biomarkers, ranged between 5.4–10.5%, well below the biological variation for all four markers. Biomarker concentrations for 31 late-stage sera correlated well (R2 = 0.71 to 0.93 for various biomarkers) with values obtained on the Luminex® platform. In a 31 patient cohort encompassing early- and late-stage ovarian cancers along with benign and healthy controls, the multiplexed p-BNC panel was able to distinguish cases from controls with 68.7% sensitivity at 80% specificity. Utility for longitudinal biomarker monitoring was demonstrated with pre-diagnostic sera from 2 cases and 4 controls. Taken together, the p-BNC shows strong promise as a diagnostic tool for large-scale screening that takes advantage of faster results and lower costs while leveraging possible improvement in sensitivity and specificity from biomarker panels. PMID:25388014
Yang, Hongmei; Kong, Qingkun; Wang, Shaowei; Xu, Jinmeng; Bian, Zhaoquan; Zheng, Xiaoxiao; Ma, Chao; Ge, Shenguang; Yu, Jinghua
2014-11-15
In this paper, a pen-on-paper electrochemiluminescence (PoP-ECL) device was entirely hand drawn and written in commercially available crayon and pencil in turn for the first time, and a constant potential-triggered sandwich-type immunosensor was introduced into the PoP-ECL device to form a low-cost ECL immunodevice proof. Each PoP-ECL device contained a hydrophilic paper channel and two PoP electrodes, and the PoP-ECL device was produced as follows: crayon was firstly used to draw hydrophobic regions on pure cellulose paper to create the hydrophilic paper channels followed with a baking treatment, and then a 6B-type black pencil with low resistivity was applied for precision writing, as the PoP electrodes, across the hydrophilic paper channel. For further point-of-care testing, a portable, low-cost rechargeable battery was employed as the power source to provide constant potential to the PoP electrodes to trigger the ECL. Using Carbohydrate antigen 199 as model analyte, this PoP-ECL immunodevice showed a good linear response range from 0.01-200 U mL(-1) with a detection limit of 0.0055 U mL(-1), a high sensitivity and stability. The proposed PoP-ECL immunodevice could be used in point-of-care testing of other tumor markers for remote regions and developing countries. Copyright © 2014 Elsevier B.V. All rights reserved.
Houben, I P L; van Berlo, C J L Y; Bekers, O; Nijssen, E C; Lobbes, M B I; Wildberger, J E
2017-01-01
To evaluate whether a handheld point-of-care (POC) device is able to predict and discriminate patients at potential risk of contrast-induced nephropathy (CIN) prior to iodine-based contrast media delivery. Between December 2014 and June 2016, women undergoing contrast-enhanced spectral mammography (CESM) with an iodine-based contrast agent were asked to have their risk of CIN assessed by a dedicated POC device (StatSensor CREAT) and a risk factor questionnaire based on national guidelines. Prior to contrast injection, a venous blood sample was drawn to compare the results of POC with regular laboratory testing. A total of 351 patients were included; 344 were finally categorized as low risk patients by blood creatinine evaluation. Seven patients had a eGFR below 60 ml/min/1.73 m 2 , necessitating additional preparation prior to contrast delivery. The POC device failed to categorize six out of seven patients (86%), leading to (at that stage) unwanted contrast administration. Two patients subsequently developed CIN after 2-5 days, which was self-limiting after 30 days. The POC device tested was not able to reliably assess impairment of renal function in our patient cohort undergoing CESM. Consequently, we still consider classic clinical laboratory testing preferable in patients at potential risk for developing CIN.
Smartphone chloridometer for point-of-care applications
NASA Astrophysics Data System (ADS)
Zhang, Chenji; Kim, Jimin P.; Creer, Michael; Yang, Jian; Liu, Zhiwen
2017-08-01
Chloride level in sweat is a major diagnostic criterion for cystic fibrosis (CF) and many other health conditions. In an effort to develop a low cost, point-of-care sweat diagnostics system for chloride concentration measurement, we demonstrated a smartphone-based chloridometer to measure sweat chloride by using our recently developed fluorescence chloride sensor. We characterized the performance of our device to validate its clinical potential. The study indicates that our smartphone-based chloridometer may potentially advance the point-of-care diagnostic system by reducing cost and improving diagnostic accuracy.
Conway, Damian P; Holt, Martin; McNulty, Anna; Couldwell, Deborah L; Smith, Don E; Davies, Stephen C; Cunningham, Philip; Keen, Phillip; Guy, Rebecca
2014-01-01
Determine HIV Combo (DHC) is the first point of care assay designed to increase sensitivity in early infection by detecting both HIV antibody and antigen. We conducted a large multi-centre evaluation of DHC performance in Sydney sexual health clinics. We compared DHC performance (overall, by test component and in early infection) with conventional laboratory HIV serology (fourth generation screening immunoassay, supplementary HIV antibody, p24 antigen and Western blot tests) when testing gay and bisexual men attending four clinic sites. Early infection was defined as either acute or recent HIV infection acquired within the last six months. Of 3,190 evaluation specimens, 39 were confirmed as HIV-positive (12 with early infection) and 3,133 were HIV-negative by reference testing. DHC sensitivity was 87.2% overall and 94.4% and 0% for the antibody and antigen components, respectively. Sensitivity in early infection was 66.7% (all DHC antibody reactive) and the DHC antigen component detected none of nine HIV p24 antigen positive specimens. Median HIV RNA was higher in false negative than true positive cases (238,025 vs. 37,591 copies/ml; p = 0.022). Specificity overall was 99.4% with the antigen component contributing to 33% of false positives. The DHC antibody component detected two thirds of those with early infection, while the DHC antigen component did not enhance performance during point of care HIV testing in a high risk clinic-based population.
Radiation Processing of Polycyclic Aromatic Hydrocarbons (PAHs) in Space: ICEE PoC
NASA Technical Reports Server (NTRS)
Mattioda, Andrew; Cruz-Diaz, Gustavo; Barnhardt, Michael; Ging, Andrew; Schneider, Todd; Vaughn, Jason; Quigley, Emmett; Phillips, Brandon
2017-01-01
Small Polycyclic Aromatic Hydrocarbon molecules or PAHs (<30 carbon atoms) have been identified in comets, meteorites, asteroids, and interplanetary dust particles in our Solar System, while PAHs in the Interstellar Medium (ISM) tend to be much larger, usually between 50 to 100 carbon atoms in size. The cause of the size disparity between PAHs found in the ISM and Solar System as well as their influence on Solar System organics is not yet understood. Two chemical evolutionary paths have been proposed to explain the inventory of solar system organics. In one the prebiotic material was formed from the radiation induced modification of large pre-solar carbon-bearing species (e.g. ISM PAHs). The second path suggests that Solar System prebiotic matter is the result of bottom-up synthesis from small reactive molecules after the Solar System was formed. In this second scenario very few ISM PAHs survived the harsh pre-solar radiation as aromatic structures. ICEE PoC (ICEE Proof of Concept) investigated factors impacting the chemical evolution of large PAHs irradiated under conditions similar to the proto-solar nebula. Likewise ICEE PoC will refine the technical parameters of the proposed ICEE (Institute for Carbon Evolution Experiment) laboratory.
Optical sensing of anticoagulation status: Towards point-of-care coagulation testing
Tripathi, Markandey M.; Hajjarian, Zeinab; Van Cott, Elizabeth M.; Nadkarni, Seemantini K.
2017-01-01
Anticoagulant overdose is associated with major bleeding complications. Rapid coagulation sensing may ensure safe and accurate anticoagulant dosing and reduce bleeding risk. Here, we report the novel use of Laser Speckle Rheology (LSR) for measuring anticoagulation and haemodilution status in whole blood. In the LSR approach, blood from 12 patients and 4 swine was placed in disposable cartridges and time-varying intensity fluctuations of laser speckle patterns were measured to quantify the viscoelastic modulus during clotting. Coagulation parameters, mainly clotting time, clot progression rate (α-angle) and maximum clot stiffness (MA) were derived from the clot viscoelasticity trace and compared with standard Thromboelastography (TEG). To demonstrate the capability for anticoagulation sensing in patients, blood samples from 12 patients treated with warfarin anticoagulant were analyzed. LSR clotting time correlated with prothrombin and activated partial thromboplastin time (r = 0.57–0.77, p<0.04) and all LSR parameters demonstrated good correlation with TEG (r = 0.61–0.87, p<0.04). To further evaluate the dose-dependent sensitivity of LSR parameters, swine blood was spiked with varying concentrations of heparin, argatroban and rivaroxaban or serially diluted with saline. We observed that anticoagulant treatments prolonged LSR clotting time in a dose-dependent manner that correlated closely with TEG (r = 0.99, p<0.01). LSR angle was unaltered by anticoagulation whereas TEG angle presented dose-dependent diminution likely linked to the mechanical manipulation of the clot. In both LSR and TEG, MA was largely unaffected by anticoagulation, and LSR presented a higher sensitivity to increased haemodilution in comparison to TEG (p<0.01). Our results establish that LSR rapidly and accurately measures the response of various anticoagulants, opening the opportunity for routine anticoagulation monitoring at the point-of-care or for patient self-testing. PMID:28771571
Moving from "optimal resources" to "optimal care" at trauma centers.
Shafi, Shahid; Rayan, Nadine; Barnes, Sunni; Fleming, Neil; Gentilello, Larry M; Ballard, David
2012-04-01
The Trauma Quality Improvement Program has shown that risk-adjusted mortality rates at some centers are nearly 50% higher than at others. This "quality gap" may be due to different clinical practices or processes of care. We have previously shown that adoption of processes called core measures by the Joint Commission and Centers for Medicare and Medicaid Services does not improve outcomes of trauma patients. We hypothesized that improved compliance with trauma-specific clinical processes of care (POC) is associated with reduced in-hospital mortality. Records of a random sample of 1,000 patients admitted to a Level I trauma center who met Trauma Quality Improvement Program criteria (age ≥ 16 years and Abbreviated Injury Scale score 3) were retrospectively reviewed for compliance with 25 trauma-specific POC (T-POC) that were evidence-based or expert consensus panel recommendations. Multivariate regression was used to determine the relationship between T-POC compliance and in-hospital mortality, adjusted for age, gender, injury type, and severity. Median age was 41 years, 65% were men, 88% sustained a blunt injury, and mortality was 12%. Of these, 77% were eligible for at least one T-POC and 58% were eligible for two or more. There was wide variation in T-POC compliance. Every 10% increase in compliance was associated with a 14% reduction in risk-adjusted in-hospital mortality. Unlike adoption of core measures, compliance with T-POC is associated with reduced mortality in trauma patients. Trauma centers with excess in-hospital mortality may improve patient outcomes by consistently applying T-POC. These processes should be explored for potential use as Core Trauma Center Performance Measures.
Smartphone-based point-of-care testing of salivary α-amylase for personal psychological measurement.
Zhang, Lin; Yang, Wentao; Yang, Yuankui; Liu, Hong; Gu, Zhongze
2015-11-07
Here we report a smartphone-based potentiometric biosensor for point-of-care testing of salivary α-amylase (sAA), which is one of the most sensitive indices of autonomic nervous system activity, and therefore a promising non-invasive biomarker for mental health. The biosensing system includes a smartphone having a sAA-detection App, a potentiometric reader and a sensing chip with preloaded reagents. The saliva sample wicks into the reaction zone on the sensing chip so that the sAA reacts with the preloaded reagents, resulting in conversion of an electron mediator Fe(CN)6(3-) to Fe(CN)6(4-). The sensing chip is then pressed by fingers to push the reaction mixture into the detection zone for the potentiometric measurement. The potential measured by the smartphone-powered potentiometric reader is sent to the smartphone App via the USB port, and converted into sAA concentration based on a calibration curve. Using our method, sAA in real human sample is quantitatively analyzed within 5 min. The results are in good agreement with that obtained using a reference method, and correlated to psychological states of the subjects.
Variation in Point-of-Care Testing of HbA1c in Diabetes Care in General Practice.
Kristensen, Troels; Waldorff, Frans Boch; Nexøe, Jørgen; Skovsgaard, Christian Volmar; Olsen, Kim Rose
2017-11-09
Background: Point-of-care testing (POCT) of HbA1c may result in improved diabetic control, better patient outcomes, and enhanced clinical efficiency with fewer patient visits and subsequent reductions in costs. In 2008, the Danish regulators created a framework agreement regarding a new fee-for-service fee for the remuneration of POCT of HbA1c in general practice. According to secondary research, only the Capital Region of Denmark has allowed GPs to use this new incentive for POCT. The aim of this study is to use patient data to characterize patients with diabetes who have received POCT of HbA1c and analyze the variation in the use of POCT of HbA1c among patients with diabetes in Danish general practice. Methods: We use register data from the Danish Drug Register, the Danish Health Service Register and the National Patient Register from the year 2011 to define a population of 44,981 patients with diabetes (type 1 and type 2 but not patients with gestational diabetes) from the Capital Region. The POCT fee is used to measure the amount of POCT of HbA1c among patients with diabetes. Next, we apply descriptive statistics and multilevel logistic regression to analyze variation in the prevalence of POCT at the patient and clinic level. We include patient characteristics such as gender, age, socioeconomic markers, health care utilization, case mix markers, and municipality classifications. Results: The proportion of patients who received POCT was 14.1% and the proportion of clinics which were "POCT clinics" was 26.9%. There were variations in the use of POCT across clinics and patients. A part of the described variation can be explained by patient characteristics. Male gender, age differences (older age), short education, and other ethnicity imply significantly higher odds for POCT. High patient costs in general practice and other parts of primary care also imply higher odds for POCT. In contrast, high patient costs for drugs and/or morbidity in terms of the Charlson
Variation in Point-of-Care Testing of HbA1c in Diabetes Care in General Practice
Kristensen, Troels; Waldorff, Frans Boch; Nexøe, Jørgen; Skovsgaard, Christian Volmar; Olsen, Kim Rose
2017-01-01
Background: Point-of-care testing (POCT) of HbA1c may result in improved diabetic control, better patient outcomes, and enhanced clinical efficiency with fewer patient visits and subsequent reductions in costs. In 2008, the Danish regulators created a framework agreement regarding a new fee-for-service fee for the remuneration of POCT of HbA1c in general practice. According to secondary research, only the Capital Region of Denmark has allowed GPs to use this new incentive for POCT. The aim of this study is to use patient data to characterize patients with diabetes who have received POCT of HbA1c and analyze the variation in the use of POCT of HbA1c among patients with diabetes in Danish general practice. Methods: We use register data from the Danish Drug Register, the Danish Health Service Register and the National Patient Register from the year 2011 to define a population of 44,981 patients with diabetes (type 1 and type 2 but not patients with gestational diabetes) from the Capital Region. The POCT fee is used to measure the amount of POCT of HbA1c among patients with diabetes. Next, we apply descriptive statistics and multilevel logistic regression to analyze variation in the prevalence of POCT at the patient and clinic level. We include patient characteristics such as gender, age, socioeconomic markers, health care utilization, case mix markers, and municipality classifications. Results: The proportion of patients who received POCT was 14.1% and the proportion of clinics which were “POCT clinics” was 26.9%. There were variations in the use of POCT across clinics and patients. A part of the described variation can be explained by patient characteristics. Male gender, age differences (older age), short education, and other ethnicity imply significantly higher odds for POCT. High patient costs in general practice and other parts of primary care also imply higher odds for POCT. In contrast, high patient costs for drugs and/or morbidity in terms of the Charlson
Gibson, Jane; Schechter-Perkins, Elissa M; Mitchell, Patricia; Mace, Sharon; Tian, Yu; Williams, Kemi; Luo, Robert; Yen-Lieberman, Belinda
2017-10-01
Point of Care Testing (POCT) provides the capability for rapid laboratory test results in patient care environments where a traditional clinical laboratory is not available. POCTs have shorter turn-around times (TATs), they may be performed by non-laboratory personnel, and the need for transport time is eliminated. The Food and Drug Administration (FDA) recently granted Clinical Laboratory Improvements Amendment (CLIA) waiver status to the cobas ® Influenza A/B & RSV assay, a rapid, accurate point-of-care test for Influenza and respiratory syncytial virus (RSV) performed on the Liat ® System. The performance characteristics of this test were determined though a multi-site study consisting of different point of care testing environments. Prospectively collected Nasopharyngeal (NP) swabs from 1361 patients seen at 8 primary care clinics and 4 emergency departments (EDs) and 295 retrospectively identified specimens were tested for Influenza A/B and RSV on the cobas ® Liat ® platform. Performance characteristics were determined through comparison to ProFlu+, a laboratory-based PCR test for Influenza A/B and RSV (reference test). Discordant specimens were adjudicated following bi-directional sequencing. The cobas ® Influenza A/B and RSV assay showed sensitivities of 99.6%, 99.3%, and 96.8% for Influenza A, Influenza B, and RSV, respectively as determined from percent positive agreement (PPA) following comparison to the reference test. Sequencing confirmed cobas ® Influenza A/B and RSV results in 49.2% of reference test discordant specimens, while crossing threshold data suggest increased sensitivity compared to the reference test. The cobas ® Influenza A/B and RSV assay was found to be a rapid, sensitive POCT for the detection of these viruses, and provides laboratory-quality PCR-based diagnostic results in point of care settings. Copyright © 2017 Elsevier B.V. All rights reserved.
Point-of-Care-Testing in Acute Stroke Management: An Unmet Need Ripe for Technological Harvest
Eltzov, Evgeni; Seet, Raymond C. S.; Marks, Robert S.; Tok, Alfred I. Y.
2017-01-01
Stroke, the second highest leading cause of death, is caused by an abrupt interruption of blood to the brain. Supply of blood needs to be promptly restored to salvage brain tissues from irreversible neuronal death. Existing assessment of stroke patients is based largely on detailed clinical evaluation that is complemented by neuroimaging methods. However, emerging data point to the potential use of blood-derived biomarkers in aiding clinical decision-making especially in the diagnosis of ischemic stroke, triaging patients for acute reperfusion therapies, and in informing stroke mechanisms and prognosis. The demand for newer techniques to deliver individualized information on-site for incorporation into a time-sensitive work-flow has become greater. In this review, we examine the roles of a portable and easy to use point-of-care-test (POCT) in shortening the time-to-treatment, classifying stroke subtypes and improving patient’s outcome. We first examine the conventional stroke management workflow, then highlight situations where a bedside biomarker assessment might aid clinical decision-making. A novel stroke POCT approach is presented, which combines the use of quantitative and multiplex POCT platforms for the detection of specific stroke biomarkers, as well as data-mining tools to drive analytical processes. Further work is needed in the development of POCTs to fulfill an unmet need in acute stroke management. PMID:28771209
Guo, Suqin; He, Lishan; Tisch, Daniel J; Kazura, James; Mharakurwa, Sungano; Mahanta, Jagadish; Herrera, Sócrates; Wang, Baomin; Cui, Liwang
2016-01-01
Good-quality artemisinin drugs are essential for malaria treatment, but increasing prevalence of poor-quality artemisinin drugs in many endemic countries hinders effective management of malaria cases. To develop a point-of-care assay for rapid identification of counterfeit and substandard artemisinin drugs for resource-limited areas, we used specific monoclonal antibodies against artesunate and artemether, and developed prototypes of lateral flow dipstick assays. In this pilot test, we evaluated the feasibility of these dipsticks under different endemic settings and their performance in the hands of untrained personnel. The results showed that the dipstick tests can be successfully performed by different investigators with the included instruction sheet. None of the artemether and artesunate drugs collected from public pharmacies in different endemic countries failed the test. It is possible that the simple dipstick assays, with future optimization of test conditions and sensitivity, can be used as a qualitative and semi-quantitative assay for rapid screening of counterfeit artemisinin drugs in endemic settings.
Ensuring quality: a key consideration in scaling-up HIV-related point-of-care testing programs
Fonjungo, Peter N.; Osmanov, Saladin; Kuritsky, Joel; Ndihokubwayo, Jean Bosco; Bachanas, Pam; Peeling, Rosanna W.; Timperi, Ralph; Fine, Glenn; Stevens, Wendy; Habiyambere, Vincent; Nkengasong, John N.
2016-01-01
Objective: The objective of the WHO/US President's Emergency Plan for AIDS Relief consultation was to discuss innovative strategies, offer guidance, and develop a comprehensive policy framework for implementing quality-assured HIV-related point-of-care testing (POCT). Methods: The consultation was attended by representatives from international agencies (WHO, UNICEF, UNITAID, Clinton Health Access Initiative), United States Agency for International Development, Centers for Disease Control and Prevention/President's Emergency Plan for AIDS Relief Cooperative Agreement Partners, and experts from more than 25 countries, including policy makers, clinicians, laboratory experts, and program implementers. Main outcomes: There was strong consensus among all participants that ensuring access to quality of POCT represents one of the key challenges for the success of HIV prevention, treatment, and care programs. The following four strategies were recommended: implement a newly proposed concept of a sustainable quality assurance cycle that includes careful planning; definition of goals and targets; timely implementation; continuous monitoring; improvements and adjustments, where necessary; and a detailed evaluation; the importance of supporting a cadre of workers [e.g. volunteer quality corps (Q-Corps)] with the role to ensure that the quality assurance cycle is followed and sustained; implementation of the new strategy should be seen as a step-wise process, supported by development of appropriate policies and tools; and joint partnership under the leadership of the ministries of health to ensure sustainability of implementing novel approaches. Conclusion: The outcomes of this consultation have been well received by program implementers in the field. The recommendations also laid the groundwork for developing key policy and quality documents for the implementation of HIV-related POCT. PMID:26807969
Baird, J Kevin; Dewi, Mewahyu; Subekti, Decy; Elyazar, Iqbal; Satyagraha, Ari W
2015-06-01
Tens of millions of patients diagnosed with vivax malaria cannot safely receive primaquine therapy against repeated attacks caused by activation of dormant liver stages called hypnozoites. Most of these patients lack access to screening for glucose-6-phosphate dehydrogenase (G6PD) deficiency, a highly prevalent disorder causing serious acute hemolytic anemia with primaquine therapy. We optimized CuCl inhibition of G6PD in normal red blood cells (RBCs) to assess G6PD diagnostic technologies suited to point of care in the impoverished rural tropics. The most widely applied technology for G6PD screening-the fluorescent spot test (FST)-is impractical in that setting. We evaluated a new point-of-care G6PD screening kit (CareStart G6PD, CSG) against FST using graded CuCl treatments to simulate variable hemizygous states, and varying proportions of CuCl-treated RBC suspensions to simulate variable heterozygous states of G6PD deficiency. In experiments double-blinded to CuCl treatment, technicians reading FST and CSG test (n = 269) classified results as positive or negative for deficiency. At G6PD activity ≤40% of normal (n = 112), CSG test was not inferior to FST in detecting G6PD deficiency (P = 0.003), with 96% vs 90% (P = 0.19) sensitivity and 75% and 87% (P = 0.01) specificity, respectively. The CSG test costs less, requires no specialized equipment, laboratory skills, or cold chain for successful application, and performs as well as the FST standard of care for G6PD screening. Such a device may vastly expand access to primaquine therapy and aid in mitigating the very substantial burden of morbidity and mortality imposed by the hypnozoite reservoir of vivax malaria. Copyright © 2015 Elsevier Inc. All rights reserved.
Emerging technologies in point-of-care molecular diagnostics for resource-limited settings.
Peeling, Rosanna W; McNerney, Ruth
2014-06-01
Emerging molecular technologies to diagnose infectious diseases at the point at which care is delivered have the potential to save many lives in developing countries where access to laboratories is poor. Molecular tests are needed to improve the specificity of syndromic management, monitor progress towards disease elimination and screen for asymptomatic infections with the goal of interrupting disease transmission and preventing long-term sequelae. In simplifying laboratory-based molecular assays for use at point-of-care, there are inevitable compromises between cost, ease of use and test performance. Despite significant technological advances, many challenges remain for the development of molecular diagnostics for resource-limited settings. There needs to be more advocacy for these technologies to be applied to infectious diseases, increased efforts to lower the barriers to market entry through streamlined and harmonized regulatory approaches, faster policy development for adoption of new technologies and novel financing mechanisms to enable countries to scale up implementation.
Multi-scale silica structures for improved point of care detection
NASA Astrophysics Data System (ADS)
Lin, Sophia; Lin, Lancy; Cho, Eunbyul; Pezzani, Gaston A. O.; Khine, Michelle
2017-03-01
The need for sensitive, portable diagnostic tests at the point of care persists. We report on a simple method to obtain improved detection of biomolecules by a two-fold mechanism. Silica (SiO2) is coated on pre-stressed thermoplastic shrink-wrap film. When the film retracts, the resulting micro- and nanostructures yield far-field fluorescence signal enhancements over their planar or wrinkled counterparts. Because the film shrinks by 95% in surface area, there is also a 20x concentration effect. The SiO2 structured substrate is therefore used for improved detection of labeled proteins and DNA hybridization via both fluorescent and bright field. Through optical characterization studies, we attribute the fluorescence signal enhancements of 100x to increased surface density and light scattering from the rough SiO2 structures. Combining with our open channel self-wicking microfluidics, we can achieve extremely low cost yet sensitive point of care diagnostics.
Point-of-Care Ultrasonography in Emergency and Critical Care Medicine.
Chen, Leon; Malek, Tony
To stabilize critically ill patients, emergency and critical care medicine providers often require rapid diagnosis and intervention. The demand for a safe, timely diagnostic device, alongside technological innovation, led to the advent of point-of-care ultrasonography (POCUS). POCUS allows the provider to gain invaluable clinical information with a high level of accuracy, leading to better clinical decision-making and improvements in patient safety. We have outlined the history of POCUS adaptation in emergency and critical care medicine and various clinical applications of POCUS described in literature.
Ko, Fiona; Drews, Steven J
2017-10-01
Acute respiratory tract infections due to influenza A/B and respiratory syncytial virus (RSV) are major causes of morbidity and mortality globally. Rapid tests for detection of these pathogens include antigen detection point of care tests (POC) and newer easy to use molecular tests. From experience, these assays improve both laboratory workflow and assay interpretation issues. However, the question of the benefits of using rapid test technology compared to routine laboratory testing for respiratory viral pathogens is still often asked. Areas covered: Specifically, this review aims to; 1) identify clinical/patient indicators that can be measured prior to and following the implementation of rapid diagnostic test for influenza and RSV, 2) provide multiple perspectives on the extent of impact of a rapid diagnostic test, including direct and indirect outcomes, and 3) identify the technological advancements in the development of rapid testing, demonstrating a timeline that transitions from antigen-based assays to molecular assays. Expert commentary: Key benefits to the use of either antigen-based or molecular rapid tests for patient care, patient flow within institutions, as well as laboratory utilization are identified. Due to improved test characteristics, the authors feel that rapid molecular tests have greater benefits than antigen-based detection methods.
Point-of-care ultrasonography by pediatric emergency physicians. Policy statement.
Marin, Jennifer R; Lewiss, Resa E
2015-04-01
Point-of-care ultrasonography is increasingly being used to facilitate accurate and timely diagnoses and to guide procedures. It is important for pediatric emergency physicians caring for patients in the emergency department to receive adequate and continued point-of-care ultrasonography training for those indications used in their practice setting. Emergency departments should have credentialing and quality assurance programs. Pediatric emergency medicine fellowships should provide appropriate training to physician trainees. Hospitals should provide privileges to physicians who demonstrate competency in point-of-care ultrasonography. Ongoing research will provide the necessary measures to define the optimal training and competency assessment standards. Requirements for credentialing and hospital privileges will vary and will be specific to individual departments and hospitals. As more physicians are trained and more research is completed, there should be one national standard for credentialing and privileging in point-of-care ultrasonography for pediatric emergency physicians.
Profile of the Alere i Influenza A & B assay: a pioneering molecular point-of-care test.
Wang, Hongmei; Deng, Jikui; Tang, Yi-Wei
2018-05-01
The Alere i Influenza A & B assay incorporates the Nicking Enzyme Amplification Reaction technique on the Alere i instrument to detect and differentiate influenza virus (Flu) A and B nucleic acids in specific specimens. Areas covered: The Alere i Influenza A & B assay was cleared by the US Food and Drug Administration for use with nasal swabs (NS) and nasopharyngeal swabs, either directly or in viral transport medium. Notably, direct use on NS was the first ever CLIA-waived nucleic acid-based test. Previously published evaluations have reported sensitivities and specificities of 55.2-100% and 62.5-100% for Flu A and 45.2-100% and 53.6-100% for Flu B, respectively. Expert commentary: The Alere i Influenza A & B assay provides a rapid and simple platform for detection and differentiation of Flu A and B. Efforts are expected to further improve sensitivity and user-friendliness for effective and widespread use in the true point-of-care setting.
Venkatesh, K; Nair, P S; Hoechter, D J; Buscher, H
2016-11-01
Haemostatic perturbations are commonly seen in extracorporeal membrane oxygenation (ECMO) patients and remain a clinical challenge, contributing significantly to morbidity and mortality. The approach to anticoagulation monitoring and the management of bleeding varies considerably across ECMO centres. Routine laboratory tests have their limitations in terms of turnaround time and specificity of information provided. Newer point-of-care testing (POCT) for coagulation may overcome these issues, as it provides information about the entire coagulation pathway from clot initiation to lysis. It is also possible to obtain qualitative information on platelet function from these tests. Furthermore, the ability to incorporate these results into a goal-directed algorithm to manage bleeding with targeted transfusion strategies appears particularly attractive and cost effective. Further studies are required to evaluate the utility of POCT to optimise bleeding and anticoagulation management in these complex patients.
Pai, Nitika Pant; Dhurat, Rachita; Potter, Martin; Behlim, Tarannum; Landry, Geneviève; Vadnais, Caroline; Rodrigues, Camilla; Joseph, Lawrence; Shetty, Anjali
2014-12-15
Multiplexed point-of-care (POC) devices can rapidly screen for HIV-related co-infections (eg, hepatitis C (HCV), hepatitis B (HBV), syphilis) in one patient visit, but global evidence for this approach remains limited. This study aimed to evaluate a multiplex POC testing strategy to expedite screening for HIV-related co-infections in at-risk populations. A multiplex strategy was developed with two subsequent versions of an investigational device Miriad. It was evaluated in two non-comparable settings and populations in two countries for feasibility of conduct, detection of new infections, preference and accuracy. Version 1 was evaluated in 375 sexually transmitted disease clinic attendees in Mumbai, India; version 2 was evaluated in 119 injection drug users in Montreal, Canada. Feasibility (completion rate) of the multiplex strategy was high (86.1% Mumbai; 92.4% Montreal). A total of 170 new infections were detected in Mumbai (56 HIV, 75 HBV, 37 syphilis, 2 HCV) versus 2 in Montreal. Preference was 60% in Mumbai and 97% in Montreal. Miriad version 1 specificities were high: HIV 99.7% (98.3% to 100%), HBV 99.3% (97.6% to 99.9%), HCV 99.7% (98.5% to 99.9%), syphilis 85.2% (80.9% to 88.8%); sensitivities were as follows: HIV 100% (94.8% to 100%), HBV 13.3% (6.6% to 23.2%), HCV 50% (1.3% to 98.7%), syphilis 86.1% (70.5% to 95.3%). With version 2, specificities improved: HIV 100% (97.2% to 100%), HBV 100% (97.3% to 100%), HCV 85.3% (73.8% to 93.0%), syphilis 98.1% (93.3% to 99.8%); sensitivities were: HIV 100% (47.3% to 100%), HCV 80.4% (66.1% to 90.6%), syphilis 100% (22.4% to 100%). A quad multiplex POC strategy for HIV and co-infections was feasible to operationalise and preferred by patients in both settings. Many new infections were identified in Mumbai and accuracy improved with version 2 of the assay. Such a strategy will help expedite screening for co-infections, particularly where baseline screening is low. These findings are valuable to practitioners
Yoon, Christina; Semitala, Fred C; Atuhumuza, Elly; Katende, Jane; Mwebe, Sandra; Asege, Lucy; Armstrong, Derek T; Andama, Alfred O; Dowdy, David W; Davis, J Luke; Huang, Laurence; Kamya, Moses; Cattamanchi, Adithya
2017-12-01
Symptom-based screening for tuberculosis is recommended for all people living with HIV. This recommendation results in unnecessary Xpert MTB/RIF testing in many individuals living in tuberculosis-endemic areas and thus poor implementation of intensified case finding and tuberculosis preventive therapy. Novel approaches to tuberculosis screening are needed to help achieve global targets for tuberculosis elimination. We assessed the performance of C-reactive protein (CRP) measured with a point-of-care assay as a screening tool for active pulmonary tuberculosis. For this prospective study, we enrolled adults (aged ≥18 years) living with HIV with CD4 cell count less than or equal to 350 cells per μL who were initiating antiretroviral therapy (ART) from two HIV/AIDS clinics in Uganda. CRP concentrations were measured at study entry with a point-of-care assay using whole blood obtained by fingerprick (concentration ≥10 mg/L defined as screen positive for tuberculosis). Sputum samples were collected for Xpert MTB/RIF testing and culture. We calculated the sensitivity and specificity of point-of-care CRP and WHO symptom-based screening in reference to culture results. We repeated the sensitivity analysis with Xpert MTB/RIF as the reference standard. Between July 8, 2013, and Dec 15, 2015, 1237 HIV-infected adults were enrolled and underwent point-of-care CRP testing. 60 (5%) patients with incomplete or contaminated cultures were excluded from the analysis. Of the remaining 1177 patients (median CD4 count 165 cells per μL [IQR 75-271]), 163 (14%) had culture-confirmed tuberculosis. Point-of-care CRP testing had 89% sensitivity (145 of 163, 95% CI 83-93) and 72% specificity (731 of 1014, 95% CI 69-75) for culture-confirmed tuberculosis. Compared with WHO symptom-based screening, point-of-care CRP testing had lower sensitivity (difference -7%, 95% CI -12 to -2; p=0·002) but substantially higher specificity (difference 58%, 95% CI 55 to 61; p<0·0001). When Xpert MTB
Opekun, Antone R; Luu, Phong; Gotschall, Ann B; Abdalla, Nageeb; Torres, Elizabeth; Rudd, Summer B; Graham, David Y; Nurgalieva, Zhannat Z; Tsuchiya, Kyoko
2006-07-01
A need exists for accurate point-of-care tests for diagnosis of Helicobacter pylori (H. pylori) infection to evaluate a rapid urine-H. pylori antibody test device for detection of H. pylori infection in a point-of-care setting in the United States. A multi-center study in a multi-ethnic population compared the RAPIRUN urine antibody test with the (13)C-urea breath test (C-UBT) and a traditional serologic test, the high-molecular-weight cell-associated protein enzyme immunoassay (HM-CAP EIA). The primary comparator was with "definite positive" and "definite negative" patients defined as a concordance of combined results of the UBT and the HM-CAP IgG EIA. Overall, 188 eligible patients were enrolled (61 men, age range: 18-73 years, including 84 Hispanics, 73 Asian-Pacific Americans, 22 Black African-Americans, 6 non-Hispanic Caucasians, and 3 of "other" ethnicity). Compared with "definite positive" and "definite negative" results, the sensitivity and specificity of the urine antibody test were 0.9 and 1.0, respectively. The urine antibody test proved suitable for point-of-care rapid diagnosis of anti-H. pylori antibodies indicative of active or past H. pylori infection.
Oyaert, Matthijs; Van Maerken, Tom; Bridts, Silke; Van Loon, Silvi; Laverge, Heleen; Stove, Veronique
2018-03-01
Point-of-care blood gas test results may benefit therapeutic decision making by their immediate impact on patient care. We evaluated the (pre-)analytical performance of a novel cartridge-type blood gas analyzer, the GEM Premier 5000 (Werfen), for the determination of pH, partial carbon dioxide pressure (pCO 2 ), partial oxygen pressure (pO 2 ), sodium (Na + ), potassium (K + ), chloride (Cl - ), ionized calcium ( i Ca 2+ ), glucose, lactate, and total hemoglobin (tHb). Total imprecision was estimated according to the CLSI EP5-A2 protocol. The estimated total error was calculated based on the mean of the range claimed by the manufacturer. Based on the CLSI EP9-A2 evaluation protocol, a method comparison with the Siemens RapidPoint 500 and Abbott i-STAT CG8+ was performed. Obtained data were compared against preset quality specifications. Interference of potential pre-analytical confounders on co-oximetry and electrolyte concentrations were studied. The analytical performance was acceptable for all parameters tested. Method comparison demonstrated good agreement to the RapidPoint 500 and i-STAT CG8+, except for some parameters (RapidPoint 500: pCO 2 , K + , lactate and tHb; i-STAT CG8+: pO 2 , Na + , i Ca 2+ and tHb) for which significant differences between analyzers were recorded. No interference of lipemia or methylene blue on CO-oximetry results was found. On the contrary, significant interference for benzalkonium and hemolysis on electrolyte measurements were found, for which the user is notified by an interferent specific flag. Identification of sample errors from pre-analytical sources, such as interferences and automatic corrective actions, along with the analytical performance, ease of use and low maintenance time of the instrument, makes the evaluated instrument a suitable blood gas analyzer for both POCT and laboratory use. Copyright © 2018 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.
3D printed auto-mixing chip enables rapid smartphone diagnosis of anemia
Plevniak, Kimberly; Campbell, Matthew; Hodges, Abby; He, Mei
2016-01-01
Clinical diagnosis requiring central facilities and site visits can be burdensome for patients in resource-limited or rural areas. Therefore, development of a low-cost test that utilizes smartphone data collection and transmission would beneficially enable disease self-management and point-of-care (POC) diagnosis. In this paper, we introduce a low-cost iPOC3D diagnostic strategy which integrates 3D design and printing of microfluidic POC device with smartphone-based disease diagnosis in one process as a stand-alone system, offering strong adaptability for establishing diagnostic capacity in resource-limited areas and low-income countries. We employ smartphone output (AutoCAD 360 app) and readout (color-scale analytical app written in-house) functionalities for rapid 3D printing of microfluidic auto-mixers and colorimetric detection of blood hemoglobin levels. The auto-mixing of reagents with blood via capillary force has been demonstrated in 1 second without the requirement of external pumps. We employed this iPOC3D system for point-of-care diagnosis of anemia using a training set of patients (nanemia = 16 and nhealthy = 6), which showed consistent measurements of blood hemoglobin levels (a.u.c. = 0.97) and comparable diagnostic sensitivity and specificity, compared with standard clinical hematology analyzer. Capable of 3D fabrication flexibility and smartphone compatibility, this work presents a novel diagnostic strategy for advancing personalized medicine and mobile healthcare. PMID:27733894
3D printed auto-mixing chip enables rapid smartphone diagnosis of anemia.
Plevniak, Kimberly; Campbell, Matthew; Myers, Timothy; Hodges, Abby; He, Mei
2016-09-01
Clinical diagnosis requiring central facilities and site visits can be burdensome for patients in resource-limited or rural areas. Therefore, development of a low-cost test that utilizes smartphone data collection and transmission would beneficially enable disease self-management and point-of-care (POC) diagnosis. In this paper, we introduce a low-cost i POC 3D diagnostic strategy which integrates 3D design and printing of microfluidic POC device with smartphone-based disease diagnosis in one process as a stand-alone system, offering strong adaptability for establishing diagnostic capacity in resource-limited areas and low-income countries. We employ smartphone output (AutoCAD 360 app) and readout (color-scale analytical app written in-house) functionalities for rapid 3D printing of microfluidic auto-mixers and colorimetric detection of blood hemoglobin levels. The auto-mixing of reagents with blood via capillary force has been demonstrated in 1 second without the requirement of external pumps. We employed this i POC 3D system for point-of-care diagnosis of anemia using a training set of patients (n anemia = 16 and n healthy = 6), which showed consistent measurements of blood hemoglobin levels (a.u.c. = 0.97) and comparable diagnostic sensitivity and specificity, compared with standard clinical hematology analyzer. Capable of 3D fabrication flexibility and smartphone compatibility, this work presents a novel diagnostic strategy for advancing personalized medicine and mobile healthcare.
NASA Astrophysics Data System (ADS)
Ray, R.; Michaud, E.; Vantrepotte, V.; Aller, R. C.; Morvan, S.; Thouzeau, G.
2016-12-01
We studied the mangrove dominated Sinnamary estuarine system in French Guiana during the dry and wet seasons in 2015 to examine the sources, transport and fate of surface water DOC, POC and DIC along the salinity gradient and the effect of tidal fluctuations on carbon dynamics. Elemental ratios, stable isotopes and optical properties (absorption) were applied as proxies to delineate the sources and molecular structure of the organic carbon. Results showed that during the wet season there were significant net inputs of POC and DOC along the salinity gradient from mangroves and enhanced surface runoff. Time series performed during the dry season at a station in channel water adjacent to mangroves revealed mangrove-derived export and exchanges of DOC and POC during the ebb and marine algae import during the flood. DOC was the dominant form of carbon in both seasons with DOC:POC ratios typically between 13 and 40. Both δ13DOC and CDOM descriptors (e.g., S275-295 and a*412) confirmed mangrove litter leaching to be the primary contributor of high molecular weight dissolved organic matter in the wet season which was replaced by marine phytoplanktonic OC during transport offshore in the dry season. CDOM aromaticity is lower in the dry season as mangrove inputs decrease. POC showed similar trends as DOC, with maximum contributions of terrestrial litter in the river and mixing zone, and in situ production dominant in the marine zone. The entire estuary is heterotrophic, exhibiting high pCO2 (837-5575µatm) and oxygen undersaturation (59-86%) in both seasons, and substantial CO2 emission fluxes (278-3671mmol m-2 d-1). Intense local remineralization and laterally transported CO2 originating from mangrove benthic respiration could account for the water column pCO2 enrichment during low tide and night time. Keywords: Organic carbon, stable isotopes, CDOM, pCO2, mangrove, French Guiana
Electrical Chips for Biological Point-of-Care Detection.
Reddy, Bobby; Salm, Eric; Bashir, Rashid
2016-07-11
As the future of health care diagnostics moves toward more portable and personalized techniques, there is immense potential to harness the power of electrical signals for biological sensing and diagnostic applications at the point of care. Electrical biochips can be used to both manipulate and sense biological entities, as they can have several inherent advantages, including on-chip sample preparation, label-free detection, reduced cost and complexity, decreased sample volumes, increased portability, and large-scale multiplexing. The advantages of fully integrated electrical biochip platforms are particularly attractive for point-of-care systems. This review summarizes these electrical lab-on-a-chip technologies and highlights opportunities to accelerate the transition from academic publications to commercial success.
Evangeliou, Nikolaos; Florou, Heleny
2013-08-01
Particulate (POC) and dissolved organic carbon (DOC) is an important parameter for the pollution assessment of coastal marine systems, especially those affected by anthropogenic, domestic, and industrial activities. In the present paper, a similar marine system (Saronikos Gulf) located in the west-central Aegean Sea (eastern Mediterranean Sea) was examined, in terms of the temporal and spatial distribution of organic carbon (POC and DOC), with respect to marine sources and pathways. POC was maximum in winter in the Saronikos Gulf, due to the bloom of phytoplankton, whereas in the Elefsis Bay (located in the north side of the Saronikos Gulf) in summer, since phytoplankton grazes in the Bay in the end of summer (except for winter). Approximately 60 % of the bulk DOC of the water column was estimated as non-refractory (labile and semi-labile), due to the major anthropogenic, domestic, and industrial effects of the region and the shallow depths. The spatial distribution of POC and DOC mainly affects the northeastern section of the Gulf, since that region has been accepted major organic discharges for a long time period, in connection to the relatively long renewal times of its waters.
Point-of-care urine tests for smoking status and isoniazid treatment monitoring in adult patients.
Nicolau, Ioana; Tian, Lulu; Menzies, Dick; Ostiguy, Gaston; Pai, Madhukar
2012-01-01
Poor adherence to isoniazid (INH) preventive therapy (IPT) is an impediment to effective control of latent tuberculosis (TB) infection. TB patients who smoke are at higher risk of latent TB infection, active disease, and TB mortality, and may have lower adherence to their TB medications. The objective of our study was to validate IsoScreen and SmokeScreen (GFC Diagnostics, UK), two point-of-care tests for monitoring INH intake and determining smoking status. The tests could be used together in the same individual to help identify patients with a high-risk profile and provide a tailored treatment plan that includes medication management, adherence interventions, and smoking cessation programs. 200 adult outpatients attending the TB and/or the smoking cessation clinic were recruited at the Montreal Chest Institute. Sensitivity and specificity were measured for each test against the corresponding composite reference standard. Test reliability was measured using kappa statistic for intra-rater and inter-rater agreement. Univariate and multivariate logistic regression models were used to explore possible covariates that might be related to false-positive and false-negative test results. IsoScreen had a sensitivity of 93.2% (95% confidence interval [CI] 80.3, 98.2) and specificity of 98.7% (94.8, 99.8). IsoScreen had intra-rater agreement (kappa) of 0.75 (0.48, 0.94) and inter-rater agreement of 0.61 (0.27, 0.90). SmokeScreen had a sensitivity of 69.2% (56.4, 79.8), specificity of 81.6% (73.0, 88.0), intra-rater agreement of 0.77 (0.56, 0.94), and inter-rater agreement of 0.66 (0.42, 0.88). False-positive SmokeScreen tests were strongly associated with INH treatment. IsoScreen had high validity and reliability, whereas SmokeScreen had modest validity and reliability. SmokeScreen tests did not perform well in a population receiving INH due to the association between INH treatment and false-positive SmokeScreen test results. Development of the next generation Smoke
Faltus, T
2016-08-01
The use of autologous fat, especially for (stem) cell-assisted lipotransfer in plastic and aesthetic surgery, has regularly been regarded as the manufacture and application of so called Advanced Therapy Medicinal Products (ATMP). However, the in-house production of such pharmaceuticals at the point-of-care (PoC) in the surgeon's practice is not permitted without an official manufacturing license. Therefore, before beginning such treatments, a pharmaceutical manufacturing license has to be granted to the surgeon to avoid criminal prosecution and negative consequences due to infringement of professional regulations. Because such a license is linked to compliance with GMP standard, in-house manufacturing of such pharmaceuticals also implies extra technical and personnel expenses. The surgeon is obliged to check that the available autologous fat based applications are in compliance with pharmaceutical legislation. Repeated infringements of pharmaceutical regulations are incompatible with medical reliability - a prerequisite for the license to practice medicine. © Georg Thieme Verlag KG Stuttgart · New York.
Comparison of Rapid Point-of-Care Tests for Detection of Antibodies to Hepatitis C Virus
Fisher, Dennis G.; Hess, Kristen L.; Erlyana, Erlyana; Reynolds, Grace L.; Cummins, Catherine A.; Alonzo, Todd A.
2015-01-01
Background. Hepatitis C is one of the most prevalent blood-borne diseases in the United States. Despite the benefits of early screening, among 3.2 million Americans who are infected with hepatitis C virus (HCV), 50%–70% are unaware of their infection status. Methods. Data were collected between 2011 and 2014, from 1048 clients who were in the following groups: (1) injection drug users, (2) women at sexual risk, (3) gay and bisexual men, and (4) transgender individuals. The sensitivity and specificity of point-of-care tests included (1) the MedMira rapid human immunodeficiency virus (HIV)/HCV antibody test, (2) MedMira hepatitis B (HBV)/HIV/HCV antibody test, (3) Chembio HCV Screen Assay used with both whole blood and (4) oral specimens, (5) Chembio HIV-HCV Assay also used with both whole blood and (6) oral specimens, (7) Chembio HIV-HCV-Syphilis Assay, and (8) OraSure HCV Rapid Antibody Test used with whole blood. The gold standard for the HCV tests were HCV enzyme immunoassay (EIA) 2.0. Results. OraSure had the highest sensitivity at 92.7% (95% confidence interval [CI] = 88.8%–96.5%) followed closely by Chembio's 3 blood tests at 92.1% (95% CI = 87.7%–96.4%), 91.5% (95% CI = 87.2%–95.7%), and 92.3% (95% CI = 88.4%–96.2%). The sensitivities of MedMira HIV/HCV and MedMira HIV/HCV/HBV tests were the lowest, at 79.1% (95% CI = 72.6%–85.5%), and 81.5% (95% CI = 75.2%–87.8%), respectively. Specificity for the OraSure was 99.8% (95% CI = 99.4%–100%); specificity for the Chembio blood tests was 99.2% (95% CI = 98.6%–99.9%), 99.4% (95% CI = 98.8%–99.9%), and 99.3% (95% CI = 98.8%–99.9%); and specificity for the MedMira was100% and 100%. False-negative results were associated with HIV and hepatitis B core antibody serostatus. Conclusions. The OraSure and Chembio blood tests (including those multiplexed with HIV and syphilis) appear to good performance characteristics. This study has identified potential limitations of rapid testing in those
A point of view: why point-of-care places are not free marketplaces.
Rambur, B; Mooney, M M
1998-01-01
Current wisdom holds that health care is a business and "as such must abide by market principles." Most nurses are not well enough versed in economic theories to credibly critique health care delivery decisions based on economic theories. The relationship of market principles to health care realities is described in basic terms to encourage nurses to "optimize patient care and influence health care policy." Physicians, who control all access points to the health care system, have enjoyed a 40-year market dominance that is "rapidly being replaced by insurance companies and for-profit investors." Providers' decisions to treat or not to treat are strongly influenced by whether the patient is in a fee-for-service or capitated payment environment.
Kost, Gerald J; Ferguson, William; Truong, Anh-Thu; Hoe, Jackie; Prom, Daisy; Banpavichit, Arirat; Kongpila, Surin
2015-01-01
Ultrahigh sensitivity and specificity assays that detect Ebola virus disease or other highly contagious and deadly diseases quickly and successfully upstream in Spatial Care Paths™ can stop outbreaks from escalating into devastating epidemics ravaging communities locally and countries globally. Even had the WHO and CDC responded more quickly and not misjudged the dissemination of Ebola in West Africa and other world regions, mobile rapid diagnostics were, and still are, not readily available for immediate and definitive diagnosis, a stunning strategic flaw that needs correcting worldwide. This article strategizes point-of-care testing for diagnosis, triage, monitoring, recovery and stopping outbreaks in the USA and other countries; reviews Ebola molecular diagnostics, summarizes USA FDA emergency use authorizations and documents why they should not be stop-gaps; and reduces community risk from internal and external infectious disease threats by enabling public health at points of need.
Nanoscale Test Strips for Multiplexed Blood Analysis
NASA Technical Reports Server (NTRS)
Chan, Eugene
2015-01-01
A critical component of the DNA Medicine Institute's Reusable Handheld Electrolyte and Lab Technology for Humans (rHEALTH) sensor are nanoscale test strips, or nanostrips, that enable multiplexed blood analysis. Nanostrips are conceptually similar to the standard urinalysis test strip, but the strips are shrunk down a billionfold to the microscale. Each nanostrip can have several sensor pads that fluoresce in response to different targets in a sample. The strips carry identification tags that permit differentiation of a specific panel from hundreds of other nanostrip panels during a single measurement session. In Phase I of the project, the company fabricated, tested, and demonstrated functional parathyroid hormone and vitamin D nanostrips for bone metabolism, and thrombin aptamer and immunoglobulin G antibody nanostrips. In Phase II, numerous nanostrips were developed to address key space flight-based medical needs: assessment of bone metabolism, immune response, cardiac status, liver metabolism, and lipid profiles. This unique approach holds genuine promise for space-based portable biodiagnostics and for point-of-care (POC) health monitoring and diagnostics here on Earth.
Glencross, Deborah K.; Coetzee, Lindi M.; Cassim, Naseem
2014-01-01
Background The South African National Health Laboratory Service (NHLS) responded to HIV treatment initiatives with two-tiered CD4 laboratory services in 2004. Increasing programmatic burden, as more patients access anti-retroviral therapy (ART), has demanded extending CD4 services to meet increasing clinical needs. The aim of this study was to review existing services and develop a service-model that integrated laboratory-based and point-of-care testing (POCT), to extend national coverage, improve local turn-around/(TAT) and contain programmatic costs. Methods NHLS Corporate Data Warehouse CD4 data, from 60–70 laboratories and 4756 referring health facilities was reviewed for referral laboratory workload, respective referring facility volumes and related TAT, from 2009–2012. Results An integrated tiered service delivery model (ITSDM) is proposed. Tier-1/POCT delivers CD4 testing at single health-clinics providing ART in hard-to-reach areas (<5 samples/day). Laboratory-based testing is extended with Tier-2/POC-Hubs (processing ≤30–40 CD4 samples/day), consolidating POCT across 8–10 health-clinics with other HIV-related testing and Tier-3/‘community’ laboratories, serving ≤40 health-clinics, processing ≤150 samples/day. Existing Tier-4/‘regional’ laboratories serve ≤100 facilities and process <350 samples/day; Tier-5 are high-volume ‘metro’/centralized laboratories (>350–1500 tests/day, serving ≥200 health-clinics). Tier-6 provides national support for standardisation, harmonization and quality across the organization. Conclusion The ITSDM offers improved local TAT by extending CD4 services into rural/remote areas with new Tier-3 or Tier-2/POC-Hub services installed in existing community laboratories, most with developed infrastructure. The advantage of lower laboratory CD4 costs and use of existing infrastructure enables subsidization of delivery of more expensive POC services, into hard-to-reach districts without reasonable access to
Pipe Overpack Container Fire Testing: Phase I & II
DOE Office of Scientific and Technical Information (OSTI.GOV)
Figueroa, Victor G.; Ammerman, Douglas J.; Lopez, Carlos
The Pipe Overpack Container (POC) was developed at Rocky Flats to transport plutonium residues with higher levels of plutonium than standard transuranic (TRU) waste to the Waste Isolation Pilot Plant (WIPP) for disposal. In 1996 Sandia National Laboratories (SNL) conducted a series of tests to determine the degree of protection POCs provided during storage accident events. One of these tests exposed four of the POCs to a 30-minute engulfing pool fire, resulting in one of the 7A drum overpacks generating sufficient internal pressure to pop off its lid and expose the top of the pipe container (PC) to the firemore » environment. The initial contents of the POCs were inert materials, which would not generate large internal pressure within the PC if heated. However, POCs are now being used to store combustible TRU waste at Department of Energy (DOE) sites. At the request of DOE’s Office of Environmental Management (EM) and National Nuclear Security Administration (NNSA), starting in 2015 SNL conducted a new series of fire tests to examine whether PCs with combustibles would reach a temperature that would result in (1) decomposition of inner contents and (2) subsequent generation of sufficient gas to cause the PC to over-pressurize and release its inner content. Tests conducted during 2015 and 2016, and described herein, were done in two phases. The goal of the first phase was to see if the PC would reach high enough temperatures to decompose typical combustible materials inside the PC. The goal of the second test phase was to determine under what heating loads (i.e., incident heat fluxes) the 7A drum lid pops off from the POC drum. This report will describe the various tests conducted in phase I and II, present preliminary results from these tests, and discuss implications for the POCs.« less
Chan, Tommy C Y; Ye, Cong; Chan, Kwok Ping; Chu, Kai On; Jhanji, Vishal
2016-09-01
To evaluate the performance of a point-of-care test for detection of matrix metalloproteinase 9 (MMP-9) levels in post-laser-assisted in situ keratomileusis (LASIK) dry eyes. A comparative study between patients with mild to moderate post-LASIK dry eyes and age-matched normal subjects was conducted. Ocular surface disease index (OSDI), tear break-up time (TBUT), and tear film MMP-9 and total protein levels were compared between the two groups. A point-of-care test device (RPS InflammaDry, Sarasota, Florida, USA) was utilised to confirm elevated MMP-9 levels in tear film. Fourteen post-LASIK dry eyes and 34 normal eyes were included. There was no significant difference in age and gender between both groups (p>0.175). The OSDI was significantly higher (25.5±7.7 vs 7.4±2.5; p<0.001) and TBUT levels were significantly lower (5.4±0.9 vs 13.5±2.3; p<0.001) in patients with dry eye compared with normal subjects. The tear film MMP-9 levels were 52.7±32.5 ng/mL in dry eyes and 4.1±2.1 ng/mL in normal eyes (p<0.001). MMP-9 levels were >40 ng/mL in 7/14 (50.0%) post-LASIK dry eyes. The InflammaDry was positive in 8/14 (57.1%) post-LASIK eyes. All positive cases had tear film MMP-9 levels ≥38.03 ng/mL. Agreement between InflammaDry and MMP-9 was excellent with Cohen κ value of 0.857 in post-LASIK dry eyes. Only half of post-LASIK dry eyes were found to have significant inflammation associated with elevated MMP-9. The OSDI is useful to non-specifically identify patients with symptomatic dry eye while the InflammaDry determined which patients with dry eye were associated with significant inflammation that may guide therapeutic management decisions. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/
Saldarriaga, Omar A.; Castellanos-Gonzalez, Alejandro; Porrozzi, Renato; Baldeviano, Gerald C.; Lescano, Andrés G.; de Los Santos, Maxy B.; Fernandez, Olga L.; Saravia, Nancy G.; Costa, Erika; Melby, Peter C.; Travi, Bruno L.
2016-01-01
Cutaneous and mucosal leishmaniasis is widely distributed in Central and South America. Leishmania of the Viannia subgenus are the most frequent species infecting humans. L. (V.) braziliensis, L. (V.) panamensis are also responsible for metastatic mucosal leishmaniasis. Conventional or real time PCR is a more sensitive diagnostic test than microscopy, but the cost and requirement for infrastructure and trained personnel makes it impractical in most endemic regions. Primary health systems need a sensitive and specific point of care (POC) diagnostic tool. We developed a novel POC molecular diagnostic test for cutaneous leishmaniasis caused by Leishmania (Viannia) spp. Parasite DNA was amplified using isothermal Recombinase Polymerase Amplification (RPA) with primers and probes that targeted the kinetoplast DNA. The amplification product was detected by naked eye with a lateral flow (LF) immunochromatographic strip. The RPA-LF had an analytical sensitivity equivalent to 0.1 parasites per reaction. The test amplified the principal L. Viannia species from multiple countries: L. (V.) braziliensis (n = 33), L. (V.) guyanensis (n = 17), L. (V.) panamensis (n = 9). The less common L. (V.) lainsoni, L. (V.) shawi, and L. (V.) naiffi were also amplified. No amplification was observed in parasites of the L. (Leishmania) subgenus. In a small number of clinical samples (n = 13) we found 100% agreement between PCR and RPA-LF. The high analytical sensitivity and clinical validation indicate the test could improve the efficiency of diagnosis, especially in chronic lesions with submicroscopic parasite burdens. Field implementation of the RPA-LF test could contribute to management and control of cutaneous and mucosal leishmaniasis. PMID:27115155