Sample records for polished thin sections

  1. A Computer Program which Uses an Expert Systems Approach to Identifying Minerals.

    ERIC Educational Resources Information Center

    Hart, Allan Bruce; And Others

    1988-01-01

    Described is a mineral identification program which uses a shell system for creating expert systems of a classification nature. Discusses identification of minerals in hand specimens, thin sections, and polished sections of rocks. (Author/CW)

  2. Antarctic Meteorite Newsletter, volume 8, number 1

    NASA Technical Reports Server (NTRS)

    1985-01-01

    Preliminary descriptions and classifications of meteorites examined since the July 1984 newsletter are presented. Each macroscopic description summarizes features that were visible to the eye (with, at most, 50X magnification). Each thin section description represents features that were found in a survey-level examination of a polished thin section that was prepared from a small (usually extrior) chip of the meteorite. Classification is based on microscopic petrography and reconnaissance-level electron-probe microanalyses.

  3. A Virtual Petrological Microscope for All Apollo 11 Lunar Samples

    NASA Technical Reports Server (NTRS)

    Pillnger, C. T.; Tindle, A. G.; Kelley, S. P.; Quick, K.; Scott, P.; Gibson, E. K.; Zeigler, R. A.

    2014-01-01

    A means of viewing, over the Internet, polished thin sections of every rock in the Apollo lunar sample collections via software, duplicaing many of the functions of a petrological microscope, is described.

  4. Effect of slurry composition on the chemical mechanical polishing of thin diamond films

    PubMed Central

    Werrell, Jessica M.; Mandal, Soumen; Thomas, Evan L. H.; Brousseau, Emmanuel B.; Lewis, Ryan; Borri, Paola; Davies, Philip R.; Williams, Oliver A.

    2017-01-01

    Nanocrystalline diamond (NCD) thin films grown by chemical vapour deposition have an intrinsic surface roughness, which hinders the development and performance of the films’ various applications. Traditional methods of diamond polishing are not effective on NCD thin films. Films either shatter due to the combination of wafer bow and high mechanical pressures or produce uneven surfaces, which has led to the adaptation of the chemical mechanical polishing (CMP) technique for NCD films. This process is poorly understood and in need of optimisation. To compare the effect of slurry composition and pH upon polishing rates, a series of NCD thin films have been polished for three hours using a Logitech Ltd. Tribo CMP System in conjunction with a polyester/polyurethane polishing cloth and six different slurries. The reduction in surface roughness was measured hourly using an atomic force microscope. The final surface chemistry was examined using X-ray photoelectron spectroscopy and a scanning electron microscope. It was found that of all the various properties of the slurries, including pH and composition, the particle size was the determining factor for the polishing rate. The smaller particles polishing at a greater rate than the larger ones. PMID:29057022

  5. Effect of slurry composition on the chemical mechanical polishing of thin diamond films

    NASA Astrophysics Data System (ADS)

    Werrell, Jessica M.; Mandal, Soumen; Thomas, Evan L. H.; Brousseau, Emmanuel B.; Lewis, Ryan; Borri, Paola; Davies, Philip R.; Williams, Oliver A.

    2017-12-01

    Nanocrystalline diamond (NCD) thin films grown by chemical vapour deposition have an intrinsic surface roughness, which hinders the development and performance of the films' various applications. Traditional methods of diamond polishing are not effective on NCD thin films. Films either shatter due to the combination of wafer bow and high mechanical pressures or produce uneven surfaces, which has led to the adaptation of the chemical mechanical polishing (CMP) technique for NCD films. This process is poorly understood and in need of optimisation. To compare the effect of slurry composition and pH upon polishing rates, a series of NCD thin films have been polished for three hours using a Logitech Ltd. Tribo CMP System in conjunction with a polyester/polyurethane polishing cloth and six different slurries. The reduction in surface roughness was measured hourly using an atomic force microscope. The final surface chemistry was examined using X-ray photoelectron spectroscopy and a scanning electron microscope. It was found that of all the various properties of the slurries, including pH and composition, the particle size was the determining factor for the polishing rate. The smaller particles polishing at a greater rate than the larger ones.

  6. Virtual Microscope Views of the Apollo 11, 12, and 15 Lunar Samples

    NASA Technical Reports Server (NTRS)

    Gibson, E. K.; Tindle, A. G.; Kelley, S. P.; Pillinger, J. M.

    2017-01-01

    The Apollo virtual microscope is a means of viewing, over the Internet, polished thin sections of every rock in the Apollo lunar sample collections. It uses software that duplicates many of the functions of a petrological microscope.

  7. Cross-sectional TEM specimen preparation for W/B{sub 4}C multilayer sample using FIB

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mondal, Puspen, E-mail: puspen@rrcat.gov.in; Pradhan, P. C.; Tiwari, Pragya

    2016-05-23

    A recent emergence of a cross-beam scanning electron microscopy (SEM)/focused-ion-beam (FIB) system have given choice to fabricate cross-sectional transmission electron microscopy (TEM) specimen of thin film multilayer sample. A 300 layer pair thin film multilayer sample of W/B{sub 4}C was used to demonstrate the specimen lift-out technique in very short time as compared to conventional cross-sectional sample preparation technique. To get large area electron transparent sample, sample prepared by FIB is followed by Ar{sup +} ion polishing at 2 kV with grazing incident. The prepared cross-sectional sample was characterized by transmission electron microscope.

  8. Lunar and Meteorite Thin Sections for Undergraduate and Graduate Studies

    NASA Astrophysics Data System (ADS)

    Allen, J.; Allen, C.

    2012-12-01

    The Johnson Space Center (JSC) has the unique responsibility to curate NASA's extraterrestrial samples from past and future missions. Curation includes documentation, preservation, preparation, and distribution of samples for research, education, and public outreach. Studies of rock and soil samples from the Moon and meteorites continue to yield useful information about the early history of the Moon, the Earth, and the inner solar system. Petrographic Thin Section Packages containing polished thin sections of samples from either the Lunar or Meteorite collections have been prepared. Each set of twelve sections of Apollo lunar samples or twelve sections of meteorites is available for loan from JSC. The thin sections sets are designed for use in domestic college and university courses in petrology. The loan period is very strict and limited to two weeks. Contact Ms. Mary Luckey, Education Sample Curator. Email address: mary.k.luckey@nasa.gov Each set of slides is accompanied by teaching materials and a sample disk of representative lunar or meteorite samples. It is important to note that the samples in these sets are not exactly the same as the ones listed here. This list represents one set of samples. A key education resource available on the Curation website is Antarctic Meteorite Teaching Collection: Educational Meteorite Thin Sections, originally compiled by Bevan French, Glenn McPherson, and Roy Clarke and revised by Kevin Righter in 2010. Curation Websites College and university staff and students are encouraged to access the Lunar Petrographic Thin Section Set Publication and the Meteorite Petrographic Thin Section Package Resource which feature many thin section images and detailed descriptions of the samples, research results. http://curator.jsc.nasa.gov/Education/index.cfm Request research samples: http://curator.jsc.nasa.gov/ JSC-CURATION-EDUCATION-DISKS@mail.nasa.govLunar Thin Sections; Meteorite Thin Sections;

  9. Removal of millimeter-scale rolled edges using bevel-cut-like tool influence function in magnetorheological jet polishing.

    PubMed

    Yang, Hao; Cheng, Haobo; Feng, Yunpeng; Jing, Xiaoli

    2018-05-01

    Subaperture polishing techniques usually produce rolled edges due to edge effect. The rolled edges, especially those in millimeter scale on small components, are difficult to eliminate using conventional polishing methods. Magnetorheological jet polishing (MJP) offers the possibility of the removal of these structures, owing to its small tool influence function (TIF) size. Hence, we investigate the removal characters of inclined MJP jetting models by means of computational fluid dynamics (CFD) simulations and polishing experiments. A discrete phase model (DPM) is introduced in the simulation to get the influence of abrasive particle concentration on the removal mechanism. Therefore, a more accurate model for MJP removal mechanisms is built. With several critical problems solved, a small bevel-cut-like TIF (B-TIF), which has fine acentric and unimodal characteristics, is obtained through inclined jetting. The B-TIF proves to have little edge effect and is applied in surface polishing of thin rolled edges. Finally, the RMS of the experimental section profile converges from 10.5 nm to 1.4 nm, and the rolled edges are successfully suppressed. Consequently, it is validated that the B-TIF has remarkable ability in the removal of millimeter-scale rolled edges.

  10. Improving FTIR imaging speciation of organic compound residues or their degradation products in wall painting samples, by introducing a new thin section preparation strategy based on cyclododecane pre-treatment.

    PubMed

    Papliaka, Zoi Eirini; Vaccari, Lisa; Zanini, Franco; Sotiropoulou, Sophia

    2015-07-01

    Fourier transform infrared (FTIR) imaging in transmission mode, employing a bidimensional focal plane array (FPA) detector, was applied for the detection and spatially resolved chemical characterisation of organic compounds or their degradation products within the stratigraphy of a critical group of fragments, originating from prehistoric and roman wall paintings, containing a very low concentration of subsisted organic matter or its alteration products. Past analyses using attenuated total reflection (ATR) or reflection FTIR on polished cross sections failed to provide any evidence of any organic material assignable as binding medium of the original painting. In order to improve the method's performance, in the present study, a new method of sample preparation in thin section was developed. The procedure is based on the use of cyclododecane C12H24 as embedding material and a subsequent double-side polishing of the specimen. Such procedure provides samples to be studied in FTIR transmission mode without losing the information on the spatial distribution of the detected materials in the paint stratigraphy. For comparison purposes, the same samples were also studied after opening their stratigraphy with a diamond anvil cell. Both preparation techniques offered high-quality chemical imaging of the decay products of an organic substance, giving clues to the painting technique. In addition, the thin sections resulting from the cyclododecane pre-treatment offered more layer-specific data, as the layer thickness and order remained unaffected, whereas the samples resulting from compression within the diamond cell were slightly deformed; however, since thinner and more homogenous, they provided higher spectral quality in terms of S/N ratio. In summary, the present study illustrates the appropriateness of FTIR imaging in transmission mode associated with a new thin section preparation strategy to detect and localise very low-concentrated organic matter subjected to deterioration processes, when the application of FTIR in reflection mode or FTIR-ATR fails to give any relevant information.

  11. The relationship between selected socioeconomic factors and thinness among Polish school-aged children and adolescents.

    PubMed

    Gurzkowska, Beata; Kułaga, Zbigniew; Grajda, Aneta; Góźdź, Magdalena; Wojtyło, Małgorzata; Litwin, Mieczysław

    2017-06-01

    The analysis was performed on a database including 17,427 records of subjects aged 7-18 years, randomly sampled from a population of Polish students. Thinness was determined using international cut-off points, defined to pass through body mass index of 18.5 kg/m 2 at the age of 18. The weighted prevalence of thinness and odds ratios with 95% confidence interval were estimated for gender, birth weight, level of schooling and school location, gross domestic product (GDP) per inhabitant, family income and maternal education. Body height was analysed according to body mass and birth weight categories. The prevalence of thinness was higher among children with low birth weight and among girls. The prevalence of thinness decreased with increasing GDP per inhabitant. In analysis by level of schooling: primary-middle-secondary, prevalence of thinness decreased among boys and increased among girls. Thin students were significantly shorter than other students, and thin girls less likely participated in physical education. Gender and socioeconomic factors are important determinants of thinness among Polish children and adolescents. Public health strategies should address family eating practices to prevent negative effects of weight deficit, especially among girls/children from low GDP regions. What is Known: • Socioeconomic factors and gender influence weight status of children and adolescents. What is New: • The first time the prevalence and determinants of thinness based on data from a nationally representative, weighted sample of Polish children aged 7-18 years were presented. • The analysis shows how gender and socioeconomics determinants influence the prevalence of thinness among children and adolescent in post-transformation country and can be used to international comparisons.

  12. LA-ICP-MS Study of Trace Elements in the Chanuskij Metal

    NASA Technical Reports Server (NTRS)

    Petaev, Michail I.

    2005-01-01

    This progress report covers work done during the second year of the 3-year proposal. During this year we resolved many issues relevant to the analytical technique developed by us for measuring trace elements in meteoritic metals. This technique was used to measure concentrations of Fe, Ni, Co, Cr, Cu, Ga, Ge, As, Mo, Ru, Rh, Pd, Sb, W, Re, Os, Ir, Pt, and Au in eight large (120 - 160 microns) metal grains from both "igneous" and "metamorphic" lithologies of the Chanuskij silicate inclusions. The first application of OUT technique to metal grains from thin sections showed some limitations. Small thickness of metal grains in the thin section limited the signal to 3-4 time-slices instead of 10- 1 1 ones in polished sections of iron meteorites studied before.

  13. Ultrafast Phase Mapping of Thin-Sections from An Apollo 16 Drive Tube - a New Visualisation of Lunar Regolith

    NASA Technical Reports Server (NTRS)

    Botha, Pieter; Butcher, Alan R.; Horsch, Hana; Rickman, Doug; Wentworth, Susan J.; Schrader, Christian M.; Stoeser, Doug; Benedictus, Aukje; Gottlieb, Paul; McKay, David

    2008-01-01

    Polished thin-sections of samples extracted from Apollo drive tubes provide unique insights into the structure of the Moon's regolith at various landing sites. In particular, they allow the mineralogy and texture of the regolith to be studied as a function of depth. Much has been written about such thin-sections based on optical, SEM and EPMA studies, in terms of their essential petrographic features, but there has been little attempt to quantify these aspects from a spatial perspective. In this study, we report the findings of experimental analysis of two thin-sections (64002, 6019, depth range 5.0 - 8.0 cm & 64001, 6031, depth range 50.0 - 53.1 cm), from a single Apollo 16 drive tube using QEMSCAN . A key feature of the method is phase identification by ultrafast energy dispersive x-ray mapping on a pixel-by-pixel basis. By selecting pixel resolutions ranging from 1 - 5 microns, typically 8,500,000 individual measurement points can be collected on a thin-section. The results we present include false colour digital images of both thin-sections. From these images, information such as phase proportions (major, minor and trace phases), particle textures, packing densities, and particle geometries, has been quantified. Parameters such as porosity and average phase density, which are of geomechanical interest, can also be calculated automatically. This study is part of an on-going investigation into spatial variation of lunar regolith and NASA's ISRU Lunar Simulant Development Project.

  14. Study of Mechano-Chemical Machining of Ceramics and the Effect on Thin Film Behavior.

    DTIC Science & Technology

    1981-06-01

    polished 7 dry on nylon using NaCI 3 Photomicrographs of the etched surfaces of MgO polished 8 .wet on glass using NaCl 4 Surface profile and Nomarski ...micrograph of a Si wafer 10 taken before mechano-chemical polishing 5 Surface profile and Nomarski micrograph of a Si wafer 11 taken after mechano... Nomarski micrographs of mechano-chemically-polished 21 sapphire and tape-cast alumina 14 Surface profiles of mechano-chemically-polished sapphire 22

  15. Polishability of thin electrolytic and electroless NiP layers

    NASA Astrophysics Data System (ADS)

    Kinast, Jan; Beier, Matthias; Gebhardt, Andreas; Risse, Stefan; Tünnermann, Andreas

    2015-10-01

    Ultra-precise metal optics are key components of sophisticated scientific instrumentation in astronomy and space applications, covering a wide spectral range. Especially for applications in the visible or ultra-violet spectral ranges, a low roughness of the optics is required. Therefore, a polishable surface is necessary. State of the art is an amorphous nickel-phosphorus (NiP) layer, which enables several polishing techniques achieving a roughness of <1 nm RMS. Typically, these layers are approximately 30 μm to 60 μm thick. Deposited on Al6061, the bimetallic effect leads to a restricted operational temperature, caused by different coefficients of thermal expansion of Al6061 and NiP. Thinner NiP layers reduce the bimetallic effect. Hence, the possible operating temperature range. A deterministic shape correction via Magnetorheological Finishing of the substrate Al6061 leads to low shape deviations prior to the NiP deposition. This allows for depositing thin NiP-layers, which are polishable via a chemical mechanical polishing technique aiming at ultra-precise metal optics. The present article shows deposition processes and polishability of electroless and electrolytic NiP layers with thicknesses between 1 μm and 10 μm.

  16. Polishing aspheric mirrors of zero-thermal expansion cordierite ceramics (NEXCERA) for space telescope

    NASA Astrophysics Data System (ADS)

    Sugawara, Jun; Kamiya, Tomohiro; Mikashima, Bumpei

    2017-09-01

    Ultra-low thermal expansion ceramics NEXCERATM is regarded as one of potential candidate materials crucial for ultralightweight and thermally-stable optical mirrors for space telescopes which are used in future optical missions satisfying extremely high observation specifications. To realize the high precision NEXCERA mirrors for space telescopes, it is important to develop a deterministic aspheric shape polishing and a precise figure correction polishing method for the NEXCERA. Magnetorheological finishing (MRF) was tested to the NEXCERA aspheric mirror from best fit sphere shape, because the MRF technology is regarded as the best suited process for a precise figure correction of the ultralightweight mirror with thin sheet due to its advantage of low normal force polishing. As using the best combination of material and MR fluid, the MRF was performed high precision figure correction and to induce a hyperbolic shape from a conventionally polished 100mm diameter sphere, and achieved the sufficient high figure accuracy and the high quality surface roughness. In order to apply the NEXCERA to a large scale space mirror, for the next step, a middle size solid mirror, 250 mm diameter concave parabola, was machined. It was roughly ground in the parabolic shape, and was lapped and polished by a computer-controlled polishing machine using sub-aperture polishing tools. It resulted in the smooth surface of 0.6 nm RMS and the figure accuracy of λ/4, being enough as pre-MRF surface. A further study of the NEXCERA space mirrors should be proceeded as a figure correction using the MRF to lightweight mirror with thin mirror sheet.

  17. A Program of Research on Microfabrication Techniques for VLSI Magnetic Devices.

    DTIC Science & Technology

    1982-11-30

    epitaxial ( LPE ) garnet films have been investigated by transmission electron microscopy B. A special technique involving physical polishing and ion milling...was used for producing ultra-thin cross-sections of the LPE garnet films . To our knowledge no one else has such capabilities. It was found that the...Materials and the Effects of Ion Implantation on them 3 2.1 The Effects of Deuterium and Oxygen Implantation on the Magnetic 3 Parameters of Garnet Films 2.2

  18. Ion microprobe mass analysis of lunar samples. Lunar sample program

    NASA Technical Reports Server (NTRS)

    Anderson, C. A.; Hinthorne, J. R.

    1971-01-01

    Mass analyses of selected minerals, glasses and soil particles of lunar, meteoritic and terrestrial rocks have been made with the ion microprobe mass analyzer. Major, minor and trace element concentrations have been determined in situ in major and accessory mineral phases in polished rock thin sections. The Pb isotope ratios have been measured in U and Th bearing accessory minerals to yield radiometric age dates and heavy volatile elements have been sought on the surfaces of free particles from Apollo soil samples.

  19. New constraints on deformation processes in serpentinite from sub-micron Raman Spectroscopy and TEM

    NASA Astrophysics Data System (ADS)

    Smith, S. A. F.; Tarling, M.; Rooney, J. S.; Gordon, K. C.; Viti, C.

    2017-12-01

    Extensive work has been performed to characterize the mineralogical and mechanical properties of the various serpentine minerals (i.e. antigorite, lizardite, chrysotile, polyhedral and polygonal serpentine). However, correct identification of serpentine minerals is often difficult or impossible using conventional analytical techniques such as optical- and SEM-based microscopy, X-ray diffraction and infrared spectroscopy. Transmission Electron Microscopy (TEM) is the best analytical technique to identify the serpentine minerals, but TEM requires complex sample preparation and typically results in very small analysis areas. Sub-micron confocal Raman spectroscopy mapping of polished thin sections provides a quick and relatively inexpensive way of unambiguously distinguishing the main serpentine minerals within their in-situ microstructural context. The combination of high spatial resolution (with a diffraction-limited system, 366 nm), large-area coverage (up to hundreds of microns in each dimension) and ability to map directly on thin sections allows intricate fault rock textures to be imaged at a sample-scale, which can then form the target of more focused TEM work. The potential of sub-micron Raman Spectroscopy + TEM is illustrated by examining sub-micron-scale mineral intergrowths and deformation textures in scaly serpentinites (e.g. dissolution seams, mineral growth in pressure shadows), serpentinite crack-seal veins and polished fault slip surfaces from a serpentinite-bearing mélange in New Zealand. The microstructural information provided by these techniques has yielded new insights into coseismic dehydration and amorphization processes and the interplay between creep and localised rupture in serpentinite shear zones.

  20. Laser polishing for topography management of accelerator cavity surfaces

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhao, Liang; Klopf, J. Mike; Reece, Charles E.

    2015-07-20

    Improved energy efficiency and reduced cost are greatly desired for advanced particle accelerators. Progress toward both can be made by atomically-smoothing the interior surface of the niobium superconducting radiofrequency accelerator cavities at the machine's heart. Laser polishing offers a green alternative to the present aggressive chemical processes. We found parameters suitable for polishing niobium in all surface states expected for cavity production. As a result, careful measurement of the resulting surface chemistry revealed a modest thinning of the surface oxide layer, but no contamination.

  1. Design and development by direct polishing of the WFXT thin polynomial mirror shells

    NASA Astrophysics Data System (ADS)

    Proserpio, L.; Campana, S.; Citterio, O.; Civitani, M.; Combrinck, H.; Conconi, P.; Cotroneo, V.; Freeman, R.; Mattini, E.; Langstrof, P.; Morton, R.; Motta, G.; Oberle, O.; Pareschi, G.; Parodi, G.; Pels, C.; Schenk, C.; Stock, R.; Tagliaferri, G.

    2017-11-01

    The Wide Field X-ray Telescope (WFXT) is a medium class mission proposed to address key questions about cosmic origins and physics of the cosmos through an unprecedented survey of the sky in the soft X-ray band (0.2-6 keV) [1], [2]. In order to get the desired angular resolution of 10 arcsec (5 arcsec goal) on the entire 1 degrees Field Of View (FOV), the design of the optical system is based on nested grazing-incidence polynomial profiles mirrors, and assumes a focal plane curvature and plate scale corrections among the shells. This design guarantees an increased angular resolution also at large off-axis positions with respect to the usually adopted Wolter I configuration. In order to meet the requirements in terms of mass and effective area (less than 1200 kg, 6000 cm2 @ 1 keV), the nested shells are thin and made of quartz glass. The telescope assembly is composed by three identical modules of 78 nested shells each, with diameter up to 1.1 m, length in the range of 200-440 mm and thickness of less than 2.2 mm. At this regard, a deterministic direct polishing method is under investigation to manufacture the WFXT thin grazing-incidence mirrors made of quartz. The direct polishing method has already been used for past missions (as Einstein, Rosat, Chandra) but based on much thicker shells (10 mm ore more). The technological challenge for WFXT is to apply the same approach but for 510 times thinner shells. The proposed approach is based on two main steps: first, quartz glass tubes available on the market are ground to conical profiles; second the pre-shaped shells are polished to the required polynomial profiles using a CNC polishing machine. In this paper, preliminary results on the direct grinding and polishing of prototypes shells made by quartz glass with low thickness, representative of the WFXT optical design, are presented.

  2. FROZEN THIN SECTIONS OF FRESH TISSUE FOR ELECTRON MICROSCOPY, WITH A DESCRIPTION OF PANCREAS AND LIVER

    PubMed Central

    Christensen, A. Kent

    1971-01-01

    A simple method has been developed that allows frozen thin sections of fresh-frozen tissue to be cut on a virtually unmodified ultramicrotome kept at room temperature. A bowl-shaped Dewar flask with a knifeholder in its depths replaces the stage of the microtome; a bar extends down into the bowl from the microtome's cutting arm and bears the frozen tissue near its lower end. When the microtome is operated, the tissue passes a glass or diamond knife in the depths of the bowl as in normal cutting. The cutting temperature is maintained by flushing the bowl with cold nitrogen gas, and can be set anywhere from about -160°C up to about -30°C. The microtome is set for a cutting thickness of 540–1000 A. Sections are picked up from the dry knife edge, and are placed on membrane-coated grids, flattened with the polished end of a copper rod, and either dried in nitrogen gas or freeze-dried. Throughout the entire process the tissue is kept cold and does not come in contact with any solvent. The morphology seen in frozen thin sections of rat pancreas and liver generally resembles that in conventional preparations, although freezing damage and low contrast limit the detail that can be discerned. Among unusual findings is a frequent abundance of mitochondrial granules in material prepared by this method. PMID:4942776

  3. Evaluating Thin Client Computers for Use by the Polish Army

    DTIC Science & Technology

    2006-06-01

    43 Figure 15. Annual Electricity Cost and Savings for 5 to 100 Users (source: Thin Client Computing...50 percent in hard costs in the first year of thin client network deployment.20 However, the greatest savings come from the reduction in soft costs ...resources from both the classrooms and home. The thin client solution increased the reliability of the IT infrastructure and resulted in cost savings

  4. Study of Mechano-Chemical Machining of Ceramics and the Effect on Thin Film Behavior.

    DTIC Science & Technology

    1983-01-01

    with Fe2O3 Under Various Pressures 9 7 Nomarski Micrographs of an Si N Substrate (a) Before *. and (b) After Mechanochemical Polishing 11 8 -Surface...the entire polished surface did not reveal any scratches. Figure 7 com- pares the Nomarski micrographs of an Si3 N4 substrate before (in the as...mechanochemically polished Si3N4 substrates, using an interferometric technique. The surface figure of a 2.5 x 2.5 cm Si 3N4 substrate is shown in Figure 9. This fig

  5. Designable ultra-smooth ultra-thin solid-electrolyte interphases of three alkali metal anodes.

    PubMed

    Gu, Yu; Wang, Wei-Wei; Li, Yi-Juan; Wu, Qi-Hui; Tang, Shuai; Yan, Jia-Wei; Zheng, Ming-Sen; Wu, De-Yin; Fan, Chun-Hai; Hu, Wei-Qiang; Chen, Zhao-Bin; Fang, Yuan; Zhang, Qing-Hong; Dong, Quan-Feng; Mao, Bing-Wei

    2018-04-09

    Dendrite growth of alkali metal anodes limited their lifetime for charge/discharge cycling. Here, we report near-perfect anodes of lithium, sodium, and potassium metals achieved by electrochemical polishing, which removes microscopic defects and creates ultra-smooth ultra-thin solid-electrolyte interphase layers at metal surfaces for providing a homogeneous environment. Precise characterizations by AFM force probing with corroborative in-depth XPS profile analysis reveal that the ultra-smooth ultra-thin solid-electrolyte interphase can be designed to have alternating inorganic-rich and organic-rich/mixed multi-layered structure, which offers mechanical property of coupled rigidity and elasticity. The polished metal anodes exhibit significantly enhanced cycling stability, specifically the lithium anodes can cycle for over 200 times at a real current density of 2 mA cm -2 with 100% depth of discharge. Our work illustrates that an ultra-smooth ultra-thin solid-electrolyte interphase may be robust enough to suppress dendrite growth and thus serve as an initial layer for further improved protection of alkali metal anodes.

  6. Tribo-mechanical properties of thin boron coatings deposited on polished cobalt alloy surfaces for orthopedic applications

    PubMed Central

    Klepper, C. C.; Williams, J. M.; Truhan, J.J.; Qu, J.; Riester, L.; Hazelton, R. C.; Moschella, J.J.; Blau, P.J.; Anderson, J.P.; Popoola, O.O.; Keitz, M.D.

    2008-01-01

    This paper presents experimental evidence that thin (<∼200 nm) boron coatings, deposited with a (vacuum) cathodic arc technique on pre-polished Co-Cr-Mo surfaces, could potentially extend the life of metal-on-polymer orthopedic devices using cast Co-Cr-Mo alloy for the metal component. The primary tribological test used a linear, reciprocating pin-on-disc arrangement, with pins made of ultra-high molecular weight polyethylene. The disks were cast Co-Cr-Mo samples that were metallographically polished and then coated with boron at a substrate bias of 500 V and at about 100 °C. The wear tests were carried out in a saline solution to simulate the biological environment. The improvements were manifested by the absence of a detectable wear track scar on the coated metal component, while significant polymer transfer film was detected on the uncoated (control) samples tested under the same conditions. The polymer transfer track was characterized with both profilometry and Rutherford Backscattering Spectroscopy. Mechanical characterization of the thin films included nano-indentation, as well as additional pin-on-disk tests with a steel ball to demonstrate adhesion, using ultra-high frequency acoustic microscopy to probe for any void occurrence at the coating-substrate interface. PMID:19340285

  7. Research on high-efficiency polishing technology of photomask substrate

    NASA Astrophysics Data System (ADS)

    Zhao, Shijie; Xie, Ruiqing; Zhou, Lian; Liao, Defeng; Chen, Xianhua; Wang, Jian

    2018-03-01

    A method of photomask substrate fabrication is demonstrated ,that the surface figure and roughness of fused silica will converge to target precision rapidly with the full aperture polishing. Surface figure of optical flats in full aperture polishing processes is primarily dependent on the surface profile of polishing pad, therefor, a improved function of polishing mechanism was put forward based on two axis lapping machine and technology experience, and the pad testing based on displacement sensor and the active conditioning method of the pad is applied in this research. Moreover , the clamping deformation of the thin glass is solved by the new pitch dispensing method. The experimental results show that the surface figure of the 152mm×152mm×6.35mm optical glass is 0.25λ(λ=633nm) and the roughness is 0.32nm ,which has meet the requirements of mask substrate for 90 45nm nodes.

  8. Pressure distribution under flexible polishing tools. I - Conventional aspheric optics

    NASA Astrophysics Data System (ADS)

    Mehta, Pravin K.; Hufnagel, Robert E.

    1990-10-01

    The paper presents a mathematical model, based on Kirchoff's thin flat plate theory, developed to determine polishing pressure distribution for a flexible polishing tool. A two-layered tool in which bending and compressive stiffnesses are equal is developed, which is formulated as a plate on a linearly elastic foundation. An equivalent eigenvalue problem and solution for a free-free plate are created from the plate formulation. For aspheric, anamorphic optical surfaces, the tool misfit is derived; it is defined as the result of movement from the initial perfect fit on the optic to any other position. The Polisher Design (POD) software for circular tools on aspheric optics is introduced. NASTRAN-based finite element analysis results are compared with the POD software, showing high correlation. By employing existing free-free eigenvalues and eigenfunctions, the work may be extended to rectangular polishing tools as well.

  9. Particle Shape Characterization of Lunar Regolith using Reflected Light Microscopy

    NASA Astrophysics Data System (ADS)

    McCarty, C. B.; Garcia, G. C.; Rickman, D.

    2014-12-01

    Automated identification of particles in lunar thin sections is necessary for practical measurement of particle shape, void characterization, and quantitative characterization of sediment fabric. This may be done using image analysis, but several aspects of the lunar regolith make such automations difficult. For example, many of the particles are shattered; others are aggregates of smaller particles. Sieve sizes of the particles span 5 orders of magnitude. The physical thickness of a thin section, at a nominal 30 microns, is large compared to the size of many of the particles. Image acquisition modes, such as SEM and reflected light, while superior to transmitted light, still have significant ambiguity as to the volume being sampled. It is also desirable to have a technique that is inexpensive, not resource intensive, and analytically robust. To this end, we have developed an image acquisition and processing protocol that identifies and delineates resolvable particles on the front surface of a lunar thin section using a petrographic microscope in reflected light. For a polished thin section, a grid is defined covering the entire thin section. The grid defines discrete images taken with 20% overlap, minimizing the number of particles that intersect image boundaries. In reflected light mode, two images are acquired at each grid location, with a closed aperture diaphragm. One image, A, is focused precisely on the front surface of the thin section. The second image, B, is made after the stage is brought toward the objective lens just slightly. A bright fringe line, analogous to a Becke line, appears inside all transparent particles at the front surface of the section in the second image. The added light in the bright line corresponds to a deficit around the particles. Particle identification is done using ImageJ and uses multiple steps. A hybrid 5x5 median filter is used to make images Af and Bf. This primarily removes very small particles just below the front surface of the section. Bf - (Bf/Af) is then computed. The division strongly enhances the fringe and the deficit, while minimizing the correlated information in A and B. The subtraction emphasizes the particle-epoxy boundaries. The resulting image is converted to binary, and then holes are filled. Cracks are removed using a median-based operator.

  10. Grinding and polishing instead of sectioning for the tissue samples with a graft: Implications for light and electron microscopy.

    PubMed

    Mukhamadiyarov, Rinat A; Sevostyanova, Victoria V; Shishkova, Daria K; Nokhrin, Andrey V; Sidorova, Olga D; Kutikhin, Anton G

    2016-06-01

    A broad use of the graft replacement requires a detailed investigation of the host-graft interaction, including both histological examination and electron microscopy. A high quality sectioning of the host tissue with a graft seems to be complicated; in addition, it is difficult to examine the same tissue area by both of the mentioned microscopy techniques. To solve these problems, we developed a new technique of epoxy resin embedding with the further grinding, polishing, and staining. Graft-containing tissues prepared by grinding and polishing preserved their structure; however, sectioning frequently required the explantation of the graft and led to tissue disintegration. Moreover, stained samples prepared by grinding and polishing may then be assessed by both light microscopy and backscattered scanning electron microscopy. Therefore, grinding and polishing outperform sectioning when applied to the tissues with a graft. Copyright © 2016 Elsevier Ltd. All rights reserved.

  11. Evaluation of laser ablation microtomy for correlative microscopy of hard tissues.

    PubMed

    Boyde, A

    2018-02-27

    Laser ablation machining or microtomy (LAM) is a relatively new approach to producing slide mounted sections of translucent materials. We evaluated the method with a variety of problems from the bone, joint and dental tissues fields where we require thin undecalcified and undistorted sections for correlative light microscopy (LM) and backscattered electron scanning electron microscopy (BSE SEM). All samples were embedded in poly-methylmethacrlate (PMMA) and flat block surfaces had been previously studied by BSE-SEM and confocal scanning light microscopy (CSLM). Most were also studied by X-yay microtomography (XMT). The block surface is stuck to a glass slide with cyanoacrylate adhesive. Setting the section thickness and levelling uses inbuilt optical coherence tomographic imaging. Tight focusing of near-infrared laser radiation in the sectioning plane gives extreme intensities causing photodisruption of material at the focal point. The laser beam is moved by a fast scanner to write a cutting line, which is simultaneously moved by an XY positioning unit to create a sectioning plane. The block is thereby released from the slide, leaving the section stuck to the slide. Light, wet polishing on the finest grade (4000 grit) silicon carbide polishing paper is used to remove a 1-2 μm thick damaged layer at the surface of the section. Sections produced by laser cutting are fine in quality and superior to those produced by mechanical cutting and can be thinner than the 'voxel' in most laboratory X-ray microtomography systems. The present extensive pilot studies have shown that it works to produce samples which we can study by both light and electron microscopy. © 2018 The Authors Journal of Microscopy © 2018 Royal Microscopical Society.

  12. Forces acting between polishing tool and workpiece surface in magnetorheological finishing

    NASA Astrophysics Data System (ADS)

    Schinhaerl, Markus; Vogt, Christian; Geiss, Andreas; Stamp, Richard; Sperber, Peter; Smith, Lyndon; Smith, Gordon; Rascher, Rolf

    2008-08-01

    Magnetorheological finishing is a computer-controlled polishing technique that is used mainly in the field of high-quality optical lens production. The process is based on the use of a magnetorheological polishing fluid that is able, in a reversible manner, to change its viscosity from a liquid state to a solid state under the control of a magnetic field. This outstanding characteristic facilitates rapid control (in milliseconds) of the yield stress, and thus the pressure applied to the workpiece surface to be polished. A three-axis dynamometer was used to measure the forces acting between the magnetorheological fluid and the workpiece surface during determination of the material removal characteristic of the polishing tool (influence function). The results of a testing series using a QED Q22-X MRF polishing machine with a 50 mm wheel assembly show that the normal forces range from about 2 to 20 N. Knowledge of the forces is essential, especially when thin workpieces are to be polished and distortion becomes significant. This paper discusses, and gives examples of, the variation in the parameters experienced during a programme of experiments, and provides examples of the value of this work.

  13. Soils from Mare Crisium - Agglutinitic glass chemistry and soil development

    NASA Technical Reports Server (NTRS)

    Hu, H.-N.; Taylor, L. A.

    1978-01-01

    Agglutinates were studied in 29 polished thin sections of grain mounts from various size fractions of six Luna 24 soil horizons. Three populations of agglutinitic glass compositions were found: a high-MgO, high-FeO group identified as a coarse-grained basaltic component; a low-MgO, low-FeO group from a highland source; and a low-MgO, high-FeO group probably from the subophitic basalt component. The presence of a significant amount of admixed highland component probably accounts for an enrichment in plagioclase and a depletion in ferromagnesian elements displayed by the agglutinitic glass compositions relative to the bulk soil.

  14. Invisible gold in Colombian auriferous soils

    NASA Astrophysics Data System (ADS)

    Bustos Rodriguez, H.; Oyola Lozano, D.; Rojas Martínez, Y. A.; Pérez Alcázar, G. A.; Balogh, A. G.

    2005-11-01

    Optic microscopy, X-ray diffraction (XRD), Mössbauer spectroscopy (MS), Electron microprobe analysis (EPMA) and secondary ions mass spectroscopy (SIMS) were used to study Colombian auriferous soils. The auriferous samples, collected from El Diamante mine, located in Guachavez-Nariño (Colombia), were prepared by means of polished thin sections and polished sections for EPMA and SIMS. Petrography analysis was made using an optical microscope with a vision camera, registering the presence, in different percentages, of the following phases: pyrite, quartz, arsenopyrite, sphalerite, chalcopyrite and galena. By XRD analysis, the same phases were detected and their respective cell parameters calculated. By MS, the presence of two types of pyrite was detected and the hyperfine parameters are: δ 1 = 0.280 ± 0.01 mm/s and Δ Q 1 = 0.642 ± 0.01 mm/s, δ 2 = 0.379 ± 0.01 mm/s and Δ Q 2 = 0.613 ± 0.01 mm/s. For two of the samples MS detected also the arsenopyrite and chalcopyrite presence. The mean composition of the detected gold regions, established by EPMA, indicated 73% Au and 27% Ag (electrum type). Multiple regions of approximately 200 × 200 μm of area in each mineral sample were analyzed by SIMS registering the presence of “invisible gold” associated mainly with the pyrite and occasionally with the arsenopyrite.

  15. Development of mirrors for precision laser gyros

    NASA Astrophysics Data System (ADS)

    Schmitt, Dirk-Roger

    1987-11-01

    Substrate polishing and interference-layer deposition techniques for the preparation of laser-gyro mirrors to operate at laser wavelength 633 nm and incidence angle 30 deg are investigated experimentally. The importance of high reflectivity and low backscatter for accurate laser-gyro angular-velocity measurement is explained, and the methods used to measure these parameters are outlined. Results for uncoated quartz glass, Zerodur, and Si monocrystal; thin Ag layers; alternate layers of SiO2 and TiO2, and Ag with a thin layer of SiO2 are presented in graphs and micrographs and characterized in detail. It is predicted that further improvements in polishing, the use of ion-beam deposition techniques, and perhaps the replacement of TiO2 with Ta2O5 will give mirrors with lower backscatter values.

  16. Thinning of PLZT ceramic wafers for sensor integration

    NASA Astrophysics Data System (ADS)

    Jin, Na; Liu, Weiguo

    2010-08-01

    Characteristics of transparent PLZT ceramics can be tailored by controlling the component of them, and therefore showed excellent dielectric, piezoelectric, pyroelectric and ferroelectric properties. To integrate the ceramics with microelectronic circuit to realize integrated applications, the ceramic wafers have to be thinned down to micrometer scale in thickness. A7/65/35 PLZT ceramic wafer was selected in this study for the thinning process. Size of the wafer was 10×10mm with an initial thickness of 300μm. A novel membrane transfer process (MTP) was developed for the thinning and integration of the ceramic wafers. In the MTP process, the ceramic wafer was bonded to silicon wafer using a polymer bonding method. Mechanical grinding method was applied to reduce the thickness of the ceramic. To minimize the surface damage in the ceramic wafer caused by the mechanical grinding, magnetorheological finishing (MRF) method was utilized to polish the wafer. White light interference (WLI) apparatus was used to monitor the surface qualities of the grinded and ploished ceramic wafers. For the PLZT membrane obtained from the MTP process, the final thickness of the thinned and polished wafer was 10μm, the surface roughness was below 1nm in rms, and the flatness was better than λ/5.

  17. Outline of Polish Morphology.

    ERIC Educational Resources Information Center

    Bidwell, Charles E.

    This volume, one of a series of concise but relatively exhaustive descriptions of the grammatical structures of the principal standard Slavic languages, contains an outline of Polish morphology. The four major sections are morphophonemics, nominal inflection, the Polish verb (Part 1--stem alternation and conjugation, and the Polish verb (Part…

  18. Imaging the Material Properties of Bone Specimens using Reflection-Based Infrared Microspectroscopy

    PubMed Central

    Acerbo, Alvin S.; Carr, G. Lawrence; Judex, Stefan; Miller, Lisa M.

    2012-01-01

    Fourier Transform InfraRed Microspectroscopy (FTIRM) is a widely used method for mapping the material properties of bone and other mineralized tissues, including mineralization, crystallinity, carbonate substitution, and collagen cross-linking. This technique is traditionally performed in a transmission-based geometry, which requires the preparation of plastic-embedded thin sections, limiting its functionality. Here, we theoretically and empirically demonstrate the development of reflection-based FTIRM as an alternative to the widely adopted transmission-based FTIRM, which reduces specimen preparation time and broadens the range of specimens that can be imaged. In this study, mature mouse femurs were plastic-embedded and longitudinal sections were cut at a thickness of 4 μm for transmission-based FTIRM measurements. The remaining bone blocks were polished for specular reflectance-based FTIRM measurements on regions immediately adjacent to the transmission sections. Kramers-Kronig analysis of the reflectance data yielded the dielectric response from which the absorption coefficients were directly determined. The reflectance-derived absorbance was validated empirically using the transmission spectra from the thin sections. The spectral assignments for mineralization, carbonate substitution, and collagen cross-linking were indistinguishable in transmission and reflection geometries, while the stoichiometric/non-stoichiometric apatite crystallinity parameter shifted from 1032 / 1021 cm−1 in transmission-based to 1035 / 1025 cm−1 in reflection-based data. This theoretical demonstration and empirical validation of reflection-based FTIRM eliminates the need for thin sections of bone and more readily facilitates direct correlations with other methods such nanoindentation and quantitative backscatter electron imaging (qBSE) from the same specimen. It provides a unique framework for correlating bone’s material and mechanical properties. PMID:22455306

  19. The Apollo 14 regolith - Petrology of cores 14210/14211 and 14220 and soils 14141, 14148, and 14149

    NASA Technical Reports Server (NTRS)

    Simon, S. B.; Papike, J. J.; Laul, J. C.

    1982-01-01

    New modal data are presented for continuous polished thin sections from double drive tube 14210/14211, and single drive tube 14220, and for polished grain mounts of four soils from the double drive tube, one from the single drive tube, and the soils 14148 (trench top), 14149 (trench bottom), and 14141 (Cone Crater). Modal data show that the Cone Crater soil is immature, whereas the 'smooth plains' soils are mature and rich in agglutinates and breccias. Neither core exhibits any major variations with depth. Microprobe analyses of mineral and glass fragments are consistent with derivation of the soils predominantly from the local rocks, with about 5-11% exotic mare component indicated by the modal data. About 4% of the glasses are SiO2- and K2O-rich granitic glasses which are comminuted mesostasis from the local melt rocks. The soils are depleted in feldspar relative to the source rocks. The preferred explanation for this depletion is that feldspar is concentrated in the less than 10 microns fines and is consumed in the formation of agglutinates, regolith breccias, and feldspathic glass.

  20. Enhancing Surface Finish of Additively Manufactured Titanium and Cobalt Chrome Elements Using Laser Based Finishing

    NASA Astrophysics Data System (ADS)

    Gora, Wojciech S.; Tian, Yingtao; Cabo, Aldara Pan; Ardron, Marcus; Maier, Robert R. J.; Prangnell, Philip; Weston, Nicholas J.; Hand, Duncan P.

    Additive manufacturing (AM) offers the possibility of creating a complex free form object as a single element, which is not possible using traditional mechanical machining. Unfortunately the typically rough surface finish of additively manufactured parts is unsuitable for many applications. As a result AM parts must be post-processed; typically mechanically machined and/or and polished using either chemical or mechanical techniques (both of which have their limitations). Laser based polishing is based on remelting of a very thin surface layer and it offers potential as a highly repeatable, higher speed process capable of selective area polishing, and without any waste problems (no abrasives or liquids). In this paper an in-depth investigation of CW laser polishing of titanium and cobalt chrome AM elements is presented. The impact of different scanning strategies, laser parameters and initial surface condition on the achieved surface finish is evaluated.

  1. Design and development of thin quartz glass WFXT polynomial mirror shells by direct polishing

    NASA Astrophysics Data System (ADS)

    Proserpio, L.; Campana, S.; Citterio, O.; Civitani, M.; Combrinck, H.; Conconi, P.; Cotroneo, V.; Freeman, R.; Langstrof, P.; Mattaini, E.; Morton, R.; Oberle, B.; Pareschi, G.; Parodi, G.; Pels, C.; Schenk, C.; Stock, R.; Tagliaferri, G.

    2010-07-01

    The Wide Field X-ray Telescope (WFXT) is a medium class mission for X-ray surveys of the sky with an unprecedented area and sensitivity. In order to meet the effective area requirement, the design of the optical system is based on very thin mirror shells, with thicknesses in the 1-2 mm range. In order to get the desired angular resolution (10 arcsec requirement, 5 arcsec goal) across the entire 1x1 degree FOV (Field Of View), the design of the optical system is based on nested modified grazing incidence Wolter-I mirrors realized with polynomial profiles, focal plane curvature and plate scale corrections. This design guarantees an increased angular resolution at large off-axis angle with respect to the normally used Wolter I configuration, making WFXT ideal for survey purposes. The WFXT X-ray Telescope Assembly is composed by three identical mirror modules of 78 nested shells each, with diameter up to 1.1 m. The epoxy replication process with SiC shells has already been proved to be a valuable technology to meet the angular resolution requirement of 10 arcsec. To further mature the telescope manufacturing technology and to achieve the goal of 5 arcsec, a deterministic direct polishing method is under investigation. The direct polishing method has already been used for past missions (as Einstein, Rosat, Chandra): the technological challenge now is to apply it for almost ten times thinner shells. Under investigation is quartz glass (fused silica), a well-known material with good thermo-mechanical and polishability characteristics that could meet our goal in terms of mass and stiffness, with significant cost and time saving with respect to SiC. Our approach is based on two main steps: first quartz glass tubes available on the market are grinded to conical profiles, and second the obtained shells are polished to the required polynomial profiles by CNC (Computer Numerical Control) polishing machine. In this paper, the first results of the direct grinding and polishing of prototypes shells made by quartz glass with low thickness, representative of the WFXT optical design, are presented.

  2. Low-hazard metallography of moisture-sensitive electrochemical cells.

    PubMed

    Wesolowski, D E; Rodriguez, M A; McKenzie, B B; Papenguth, H W

    2011-08-01

    A low-hazard approach is presented to prepare metallographic cross-sections of moisture-sensitive battery components. The approach is tailored for evaluation of thermal (molten salt) batteries composed of thin pressed-powder pellets, but has general applicability to other battery electrochemistries. Solution-cast polystyrene is used to encapsulate cells before embedding in epoxy. Nonaqueous grinding and polishing are performed in an industrial dry room to increase throughput. Lapping oil is used as a lubricant throughout grinding. Hexane is used as the solvent throughout processing; occupational exposure levels are well below the limits. Light optical and scanning electron microscopy on cross-sections are used to analyse a thermal battery cell. Spatially resolved X-ray diffraction on oblique angle cut cells complement the metallographic analysis. Published 2011. This article is a US Government work and is in the public domain in the USA.

  3. Thin fused silica shells for high-resolution and large collecting area x-ray telescopes (like Lynx/XRS)

    NASA Astrophysics Data System (ADS)

    Civitani, M. M.; Hołyszko, J.; Vecchi, G.; Basso, S.; Citterio, O.; Ghigo, M.; Pareschi, G.; Parodi, G.; Incorvaia, S.

    2017-09-01

    The implementation of an X-ray mission with high imaging capabilities, similar to those achieved with Chandra (< 1 arc second Half Energy Width, HEW), but with a much larger throughput (2.5 m2 effective area @1 keV), represents a compelling request by the scientific community. To this end the Lynx/XRS mission is being studied in USA, with the participation of international partners. In order to figure out the challenging technological task of the mirror fabrication, different approaches are considered, based on monolithic and segmented shells. Starting from the experience done on the glass prototypal shell realized in the past years, the direct polishing of thin (2 mm thick) fused silica monolithic shells is being investigated as a possible solution. A temporary stiffening structure is designed to support the shell during the figuring and polishing operations and to manage the handling up to its integration in the telescope structure. After the grinding and the polishing phases, in order to achieve the required surface accuracy, a final ion beam figuring correction is foreseen. In this paper, we present the technological process and the results achieved so far on a prototypal shell under development.

  4. Advances in photonic MOEMS-MEMS device thinning and polishing

    NASA Astrophysics Data System (ADS)

    McAneny, James J.; Kennedy, Mark; McGroggan, Tom

    2010-02-01

    As devices continue to increase in density and complexity, ever more stringent specifications are placed on the wafer scale equipment manufacturers to produce higher quality and higher output. This results in greater investment and more resource being diverted into producing tools and processes which can meet the latest demanding criteria. Substrate materials employed in the fabrication process range from Silicon through InP and include GaAs, InSb and other optical networking or waveguide materials. With this diversity of substrate materials presented, controlling the geometries and surfaces grows progressively more challenging. This article highlights the key parameters which require close monitoring and control in order to produce highly precise wafers as part of the fabrication process. Several as cut and commercially available standard polished wafer materials were used in empirical trials to test tooling options in generating high levels of geometric control over the dimensions while producing high quality surface finishes. Specific attention was given to the measurement and control of: flatness; parallelism/TTV; surface roughness and final target thickness as common specifications required by the industry. By combining the process variables of: plate speed, download pressure, slurry flow rate and concentration, pad type and wafer travel path across the polish pad, the effect of altering these variables was recorded and analysed to realize the optimum process conditions for the materials under test. The results being then used to design improved methods and tooling for the thinning and polishing of photonic materials applied to MOEMS-MEMS device fabrication.

  5. Impact of initial surface parameters on the final quality of laser micro-polished surfaces

    NASA Astrophysics Data System (ADS)

    Chow, Michael; Bordatchev, Evgueni V.; Knopf, George K.

    2012-03-01

    Laser micro-polishing (LμP) is a new laser-based microfabrication technology for improving surface quality during a finishing operation and for producing parts and surfaces with near-optical surface quality. The LμP process uses low power laser energy to melt a thin layer of material on the previously machined surface. The polishing effect is achieved as the molten material in the laser-material interaction zone flows from the elevated regions to the local minimum due to surface tension. This flow of molten material then forms a thin ultra-smooth layer on the top surface. The LμP is a complex thermo-dynamic process where the melting, flow and redistribution of molten material is significantly influenced by a variety of process parameters related to the laser, the travel motions and the material. The goal of this study is to analyze the impact of initial surface parameters on the final surface quality. Ball-end micromilling was used for preparing initial surface of samples from H13 tool steel that were polished using a Q-switched Nd:YAG laser. The height and width of micromilled scallops (waviness) were identified as dominant parameter affecting the quality of the LμPed surface. By adjusting process parameters, the Ra value of a surface, having a waviness period of 33 μm and a peak-to-valley value of 5.9 μm, was reduced from 499 nm to 301 nm, improving the final surface quality by 39.7%.

  6. Precision Rolled-Ink Nano-Technology; Development of a Direct Write Technique for the Fabrication of Thin Films and Conductive Elements

    DTIC Science & Technology

    2012-10-01

    Fabrication of Thin Films and Conductive Elements Larry R. Holmes, Jr. Weapons and Materials Research Directorate, ARL...polymer composites, glass, metals, ceramics , and others. Development of the PRINT system and future work are discussed. 15. SUBJECT TERMS direct write...7 Figure 5. PRINT deposition on (left) polished aluminum sheet metal, and (right) aluminum oxide ceramic tile

  7. Wavelength-switchable passively mode-locked fiber laser with mechanically exfoliated molybdenum ditelluride on side-polished fiber

    NASA Astrophysics Data System (ADS)

    Wang, Guomei

    2017-11-01

    We experimentally investigated the nonlinear saturable absorption characteristics of molybdenum ditelluride (MoTe2) and demonstrated a wavelength-switchable mode-locked erbium-doped fiber laser (EDFL) by using MoTe2 thin film on side-polished fiber (SPF) as saturable absorber. Here, the MoTe2 thin film was efficiently fabricated via mechanical exfoliation method and transferred onto the SPF with the assistance of polydimethylsiloxane (PDMS). MoTe2-covered SPF (MSPF) exhibits the nonlinear saturable absorption for pulses with different polarization states. Optical solitons with spectral bandwidth of 1.06 (1.31) nm centered at ∼1559 (∼1528) nm and pulse duration of 2.46 (2.04) ps can be obtained from the EDFL by adjusting the polarization controller (PC) properly. The time-bandwidth product (TBP) of the pulses was calculated as 0.322 (0.344).

  8. Effect of air abrasion and polishing on primary molar fissures.

    PubMed

    Lenzi, T L; Menezes, L B R; Soares, F Z M; Rocha, R O

    2013-04-01

    To evaluate the effect of air abrasion and polishing on primary molar fissures under light microscopy. 15 exfoliated primary second molars were longitudinally sectioned and photographed under a stereomicroscope (40×; baseline evaluation). Sections were then randomly allocated into one of the two groups (n = 15) and treated by either air abrasion (aluminium oxide jet) or air polishing (sodium bicarbonate jet) for 30 s. After treatment, sections were washed with an air/water spray, dried with absorbent paper, and photographed as previously described (final evaluation). Baseline and final morphology were compared by two blinded examiners who evaluated changes in the width and depth of fissures. The percentage of changed fissures was analysed, and the two treatments were compared using the Mann-Whitney test (α = 0.01). Both air systems resulted in fissure changes in most (93.3 %) of the sections. No significant differences in fissure width changes were found between treatments, but when changes in fissure depth were evaluated, air polishing was found to be less damaging than air abrasion (p < 0.01). Air abrasion and polishing cause changes to the anatomical configuration of occlusal fissures of primary molars.

  9. Strength advantages of chemically polished boron fibers before and after reaction with aluminum

    NASA Technical Reports Server (NTRS)

    Dicarlo, J. A.; Smith, R. J.

    1982-01-01

    In order to determine their strength potential, the fracture properties of different types of commercial boron fibers were measured before and after application of secondary strengthening treatments. The principal treatments employed were a slight chemical polish, which removed low strength surface flaws, and a heat treatment in oxygen, which contracted the fibers and thereby compressed intrinsic bulk flaws. Those fiber types most significantly strengthened were 200 to 400 micrometers (8 to 16 mil) diameter boron on tungsten fibers produced in a single chemical vapor deposition reactor. The slight polish increased average tensile strenghts from 3.4 to 4.4 CN/m2 (500 to 640 ksi) and reduced coefficients of variation from about 15 to 3 percent. The oxygen heat treatment plus slight polish further improved average strengths to 5.5 GN/m2 (800 ksi) with coefficients near 3 percent. To ascertain whether these excellent properties could be retained after fabrication of B/Al composites, as produced and polished 203 micrometers (8 mil) fibers were thinly coated with aluminum, heat treated at B/Al fabrication temperatures, and then tested in tension and flexure at room temperature. The pre-polished fibers were observed to retain their superior strengths to higher temperatures than the as-produced fibers even though both were subjected to the same detrimental reaction with aluminum.

  10. Cost-effective masks for deep x-ray lithography

    NASA Astrophysics Data System (ADS)

    Scheunemann, Heinz-Ulrich; Loechel, Bernd; Jian, Linke; Schondelmaier, Daniel; Desta, Yohannes M.; Goettert, Jost

    2003-04-01

    The production of X-ray masks is one of the key techniques for X-ray lithography and the LIGA process. Different ways for the fabrication of X-ray masks has been established. Very sophisticated, difficult and expensive procedures are required to produce high precision and high quality X-ray masks. In order to minimize the cost of an X-ray mask, the mask blank must be inexpensive and readily available. The steps involved in the fabrication process must also be minimal. In the past, thin membranes made of titanium, silicon carbide, silicon nitride (2-5μm) or thick beryllium substrates (500μm) have been used as mask blanks. Thin titanium and silicon compounds have very high transparency for X-rays; therefore, these materials are predestined for use as mask membrane material. However, the handling and fabrication of thin membranes is very difficult, thus expensive. Beryllium is highly transparent to X-rays, but the processing and use of beryllium is risky due to potential toxicity. During the past few years graphite based X-ray masks have been in use at various research centers, but the sidewall quality of the generated resist patterns is in the range of 200-300 nm Ra. We used polished graphite to improve the sidewall roughness, but polished graphite causes other problems in the fabrication of X-ray masks. This paper describes the advantages associated with the use of polished graphite as mask blank as well as the fabrication process for this low cost X-ray mask. Alternative membrane materials will also be discussed.

  11. Not Only Jumps, Slumps, but Also "Mini Plateau." Creative Potential Assessed by the Test for Creative Thinking-Drawing Production. A Cross-Sectional Study of Polish Students Aged from 7 to 18

    ERIC Educational Resources Information Center

    Jastrzebska, Dominika; Limont, Wieslawa

    2017-01-01

    The purpose of this cross-sectional study was to examine the developmental trajectory of creative potentials of Polish students. A total of 1,522 Polish students aged between 7 and 18 from lower and upper primary school, middle school, and high school participated in the study. Creative potential was measured by means of the Test for Creative…

  12. Petrographic and petrological studies of lunar rocks. [from the Apollo 15 mission

    NASA Technical Reports Server (NTRS)

    Winzer, S. R.

    1978-01-01

    Thin sections and polished electron probe mounts of Apollo 15 glasscoated breccias 15255, 15286, 15466, and 15505 were examined optically and analyzed by sem/microprobe. Sections from breccias 15465 and 15466 were examined in detail, and chemical and mineralogical analyses of several larger lithic clasts, green glass, and partly crystallized green glass spheres are presented. Area analyses of 33 clasts from the above breccias were also done using the SEM/EDS system. Mineralogical and bulk chemical analyses of clasts from the Apollo 15 glass-coated breccias reveal a diverse set of potential rock types, including plutonic and extrusive igneous rocks and impact melts. Examination of the chemistry of the clasts suggests that many of these clasts, like those found in 61175, are impact melts. Their variability suggests formation by several small local impacts rather than by a large basin-forming event.

  13. Stratigraphy and depositional history of the Apollo 17 drill core

    NASA Technical Reports Server (NTRS)

    Taylor, G. J.; Warner, R. D.; Keil, K.

    1979-01-01

    Lithologic abundances obtained from modal analyses of a continuous string of polished thin sections indicate that the Apollo 17 deep drill core can be divided into three main zones: An upper zone (0-19 cm depth) characterized by high abundances of agglutinates (30%) and a high ratio of mare to non-mare lithic fragments (less than 0.8); a coarse-grained layer (24-56 cm) rich in fragments of high-Ti mare basalts and mineral fragments derived from them, and poor in agglutinates (6%); and a lower zone (56-285 cm) characterized by variable but generally high agglutinate abundances (25%) and a low ratio of mare to nonmare lithic fragments (0.6). Using observations of the geology of the landing site, the principles of cratering dynamics, and the vast amount of data collected on the core, the following depositional history for the section of regolith sampled by the Apollo 17 drill core: was devised.

  14. Quantitative assessment of alkali-reactive aggregate mineral content through XRD using polished sections as a supplementary tool to RILEM AAR-1 (petrographic method)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Castro, Nelia, E-mail: nelia.castro@ntnu.no; Sorensen, Bjorn E.; Broekmans, Maarten A.T.M.

    The mineral content of 5 aggregate samples from 4 different countries, including reactive and non-reactive aggregate types, was assessed quantitatively by X-ray diffraction (XRD) using polished sections. Additionally, electron probe microanalyzer (EPMA) mapping and cathodoluminescence (CL) were used to characterize the opal-CT identified in one of the aggregate samples. Critical review of results from polished sections against traditionally powdered specimen has demonstrated that for fine-grained rocks without preferred orientation the assessment of mineral content by XRD using polished sections may represent an advantage over traditional powder specimens. Comparison of data on mineral content and silica speciation with expansion data frommore » PARTNER project confirmed that the presence of opal-CT plays an important role in the reactivity of one of the studied aggregates. Used as a complementary tool to RILEM AAR-1, the methodology suggested in this paper has the potential to improve the strength of the petrographic method.« less

  15. Histological biocompatibility of a stainless steel miniature glaucoma drainage device in humans: a case report.

    PubMed

    De Feo, Fabio; Jacobson, Stewart; Nyska, Abraham; Pagani, Paola; Traverso, Carlo Enrico

    2009-06-01

    The purpose of this study was to evaluate the histological biocompatibility of a stainless steel miniature glaucoma drainage device. Twenty-four months before death due to heart failure, this seventy-three-year-old female patient underwent filtration surgery for primary open-angle glaucoma uncontrolled in the right eye. The device was implanted at the limbus under a scleral flap. For histopathological evaluation, two corneoscleral specimens were embedded in methacrylate blocks sectioned to a thickness of 50 microns, polished and stained with periodic acid schiff. Some sections included a longitudinal cross-section of the implant. At the interface between the spur and the flange of the device and the cornea, there was a small shoulder of fibrous tissue. A thin, fibrous capsule covered the remainder of the body of the device up to the distal tip. No inflammatory cells occurred within the fibrous capsule. No material or blockage was noted within the lumen. Our results support the biological inertness of the device.

  16. Aubrite basalt vitrophyres: High sulfur silicate melts and a snapshot of aubrite formation. [Abstract only

    NASA Technical Reports Server (NTRS)

    Fogel, R. A.

    1994-01-01

    Two aubrite basalt vitrophyre clasts have been found within AMNH thin sections from the Parsa EH3 chondrite and the Khor Temiki aubrite. Polished sections of the Parsa Aubrite Inclusion (PAI) and the Khor Temiki Inclusion (KTI) were studied by optical, electron probe microanalysis (EPMA), and scanning electron microscopy (SEM) techniques with broad-beam and low absorbed EPMA currents used to minimize glass volatile loss. Some data have previously been reported for PAI and KTI may possibly correlate to a previously reported inclusion in Khor Tiimiki. In polished sections, PAI and KTI are approximately equal 4 mm in diameter and contain a large volume of glass. The clasts have similar textural characteristics and are akin to lunar vitrophyre textures. The glasses have high alkali rhyodacitic compositions Al-though PAI is peraluminous, KTI is significantly peralkaline. Additionally, the glasses have elevated sulfur concentrations that are extremely high by geochemical standards. SEM examination for beam overlap of microscopic CaS, FeS, and (Mg, Mn, Fe) S inclusions showed no such contamination. Furthermore, homogeneity of glass S content and low FeO contents help rule out contamination. Materials research data show that under reducing conditions alumino-silicate melts can dissolve up to several weight percent sulfur in the absence of Fe. The high S and alkali contents, the lack of associated high shock features, and the rationalized phase equilibria suggest that PAI and KTI are igneous melting products of an E-chondrite-like source material. Although large-scale impact melting cannot totally be ruled out, the above observations eliminate the possibility of in-situ shock melting.

  17. Biocorrosion investigation of two shape memory nickel based alloys: Ni-Mn-Ga and thin film NiTi.

    PubMed

    Stepan, L L; Levi, D S; Gans, E; Mohanchandra, K P; Ujihara, M; Carman, G P

    2007-09-01

    Thin film nitinol and single crystal Ni-Mn-Ga represent two new shape memory materials with potential to be used as percutaneously placed implant devices. However, the biocompatibility of these materials has not been adequately assessed. Immersion tests were conducted on both thin film nitinol and single crystal Ni-Mn-Ga in Hank's balanced salt solution at 37 degrees C and pH 7.4. After 12 h, large pits were found on the Ni-Mn-Ga samples while thin film nitinol displayed no signs of corrosion. Further electrochemical tests on thin film nitinol samples revealed breakdown potentials superior to a mechanically polished nitinol disc. These results suggest that passivation or electropolishing of thin film nitinol maybe unnecessary to promote corrosion resistance.

  18. Proposal of Polish guidelines for conducting financial analysis and their comparison to existing guidance on budget impact in other countries.

    PubMed

    Orlewska, Ewa; Mierzejewski, Piotr

    2004-01-01

    Financial analysis (budget impact analysis, BIA) is increasingly required by decision-makers to ascertain the macroeconomic consequences of new product reimbursement in addition to proof of cost-effectiveness. Poland is in the process of drafting country-specific guidelines for BIA, positioned as complementary to economic evaluation in decision-making The aim of this article is to present the Polish project and compare it with currently available guidance. A checklist was developed that focuses on issues that are unique to BIA. An analysis of the differences between different national guidelines and their Polish counterparts was subsequently undertaken. The Polish project of BIA guidelines is composed of two sections. The first section presents the objective, the use of BIA, the responsibility for the preparation, and the target audience. The second section presents important methodological aspects that researchers should keep in mind when carrying out BIA. In comparison to existing guidance the Polish project appears to be more detailed. It includes more precise recommendations on perspective, time horizon, and reliability of data sources; reporting of results; rates of adoption of new therapies; and the probability of redeploying resources. Although there is an increased demand for BIA, there is only limited guidance on how such studies should be undertaken. It is hoped that the Polish guidelines can contribute to the development of such analyses and deliver benefit for Polish health-care decision-makers and beyond.

  19. Distribution of Apollo 15 lunar samples: News release

    NASA Technical Reports Server (NTRS)

    Dick, L.

    1971-01-01

    More than 2200 Apollo 15 samples and polished thin sections weighing a total of about three kilograms will be distributed to 201 principal investigators for study during the next year. The scientific investigations will provide detailed information on the samples' mineralogy, petrology, chemistry, age, and history and on the effects of micrometeorite impacts, solar radiation, and cosmic ray bombardment. Preliminary examination of samples show the Apollo 15 material to be of three types: dark colored iron-rich basalts associated with mare and rille formation; a few basalts enriched in feldspar collected near the Apennine front; and light colored fragmental rocks or breccias consisting of soil-like materials which were cemented together or of rock fragments which were welded together by partial remelting.

  20. Synthesis, characterization, and pulsed laser ablation of molecular sieves for thin film applications

    NASA Astrophysics Data System (ADS)

    Munoz, Trinidad, Jr.

    1998-12-01

    Molecular sieves are one class of crystalline low density metal oxides which are made up of one-, two-, and three dimensional pores and/or cages. We have investigated the synthesis and characterization of metal substituted aluminophosphates and all silica molecular sieves for thin film applications. A new copper substituted aluminophosphate, CuAPO-5 has been synthesized and characterized using x-ray powder diffraction, FT-IR spectroscopy and scanning electron microscopy. Electron spin resonance and electron spin echo modulation provided supporting evidence of framework incorporation of Cu(II) ions. Thus, an exciting addition has been added to the family of metal substituted aluminophosphates where substitution of the metal has been demonstrated as framework species. Also presented here is the synthesis and characterization of an iron substituted aluminophosphate, FeAPO-5, and an all silica zeolite, UTD-1 for thin film applications. Pulsed laser ablation has been employed as the technique to generate thin films. Here an excimer laser (KrFsp*, 248 nm) was used to deposit the molecular sieves on a variety of substrates including polished silicon, titanium nitride, and porous stainless steel disks. The crystallinity of the deposited films was enhanced by a post hydrothermal treatment. A vapor phase treatment of the laser deposited FeAPO-5 films has been shown to increase the crystallinity of the film without increasing film thickness. Thin films of the FeAPO-5 molecular sieves were subsequently used as the dielectric phase in capacitive type chemical sensors. The capacitance change of the FeAPO-5 devices to the relative moisture makes them potential humidity sensors. The all silica zeolite UTD-1 thin films were deposited on polished silicon and porous supports. A brief post hydrothermal treatment of the laser deposited films deposited on polished silicon and porous metal supports resulted in oriented film growth lending these films to applications in gas separations and catalysis. The oriented UTD-1 membrane was evaluated for the separation of n-heptane/toluene mixture. Practicum two. It has been previously observed that residual moisture plays a role in ETV-ICP-MS by altering signal intensity. Here is reported observed signal intensities with ETV-ICP-MS, resulting from the use of hydrogen, nitrogen and ascorbic acid. The use of ascorbic acid yielded enhanced signal intensity, reproducibility and linearity compared to inorganic modifiers'.

  1. Fabrication of a high-precision spherical micromirror by bending a silicon plate with a metal pad.

    PubMed

    Wu, Tong; Hane, Kazuhiro

    2011-09-20

    We demonstrate here the fabrication of a smooth mirror surface by bending a thin silicon plate. A spherical surface is achieved by the bending moment generated in the circumference of the micromirror. Both convex and concave spherical micromirrors are realized through the anodic bonding of silicon and Pyrex glass. Since the mirror surface is originated from the polished silicon surface and no additional etching is introduced for manufacturing, the surface roughness is thus limited to the polishing error. This novel approach opens possibilities for fabricating a smooth surface for micromirror and microlens applications.

  2. Formation of 4H-closely packed structure in thin films of metastable nanocrystalline Co 13Cu 87 alloy

    NASA Astrophysics Data System (ADS)

    Khalyapin, D. L.; Kim, J.; Stolyar, S. V.; Turpanov, I. A.; Kim, P. D.; Kim, I.

    2003-11-01

    The crystal structure of the thin films of metastable Co 13Cu 87 alloy prepared by magnetron sputtering was investigated by transmission electron microscope. As-deposited films have a nanocrystal structure with an fcc lattice. As a result of the prolonged ion polishing with a beam of Ar ions with the energy of 4.7 keV, the four-layer 4H dhcp structure was formed.

  3. Thin fused silica optics for a high angular resolution and large collecting area X Ray telescope after Chandra

    NASA Astrophysics Data System (ADS)

    Pareschi, Giovanni; Citterio, Oberto; Civitani, Marta M; Basso, Stefano; Campana, Sergio; Conconi, Paolo; Ghigo, Mauro; Mattaini, Enrico; Moretti, Alberto; Parodi, Giancarlo; Tagliaferri, Gianpiero

    2014-08-01

    The implementation of an X-ray mission with high imaging capabilities, similar to those achieved with Chandra (<1 arcsec Half Energy Width, HEW), but with a much larger throughput is very attractive, even if challenging. For such a mission the scientific opportunities, in particular for the study of the early Universe, would remain at the state of the art for the next decades. Initially the ESA-led XEUS mission was proposed, with an effective area of several m2 and an angular resolution better than 2 arcsec HEW. Unfortunately, this mission was not implemented, mainly due to the costs and the low level of technology readiness. Currently the most advanced proposal for such a mission is the SMART-X project, led by CfA together with other US institutes. This project is based on adjustable segments of thin foil mirrors with piezo-electric actuators, aiming to achieve an effective area >2 m2 at 1 keV and an angular resolution better than 1 arcsec HEW. Another attractive technology to realize an X-ray telescope with similar characteristics is being developed at NASA/Goddard. In this case the mirrors are based on Si substrates that are super-polished and figured starting from a bulky Si ingot, from which they are properly cut. Here we propose an alternative method based on precise direct grinding, figuring and polishing of thin (a few mm) glass shells with innovative deterministic polishing methods. This is followed by a final correction via ion figuring to obtain the desired accuracy. For this purpose, a temporary stiffening structure is used to support the shell from the polishing operations up to its integration in the telescope supporting structure. This paper deals with the technological process under development, the results achieved so far and some mission scenarios based on this kind of optics, aiming to achieve an effective area more than 10 times larger than Chandra and an angular resolution of 1 arcsec HEW on axis and of a few arcsec off-axis across a large field of view (1o in diameter).

  4. A new technique for the rapid screening and selection of large pieces of tissue for ultrastructural evaluation.

    PubMed

    Dalley, B K; Seliger, W G

    1980-05-01

    A simple and rapid technique is described for the screening of Epon embedded organ slices for the location, isolation, and removal of small specific sites for ultrastructural study with the transmission electron microscope. This procedure consists of perfusion fixation followed by making 1 to 21/2 mm thick slices of relatively large pieces of the organs, control of the degree and evenness of the osmium staining by addition of 3% sodium iodate, and infiltration with a fluorescent dye prior to embedment in Epon. Tissue slices are embedded in wafer-shaped blocks, generally with several slices in one "wafer", and are examined in a controlled manner using a rapid form of serial surface polishing. Each level of the polished wafer is examined using an epi-illuminated fluorescence microscope, and selected sites are chosen at each level for ultrastructural study. Methods are also described for marking each selected site using a conventional slide marker, and for the removal of the selected site in the form of a small disc of Epon, after which the Epon wafer can be further serially polished and the examination continued. Areas to be thin-sectioned are removed using a core drill mounted on a model-maker's drill press. The technique is simple, does not require the destruction of remaining tissues to evaluate more critically a single small site, allows for the easy maintenance of tissue orientation, and the most time-consuming portions of the technique can be quickly taught to a person with no previous histological training.

  5. The design, construction and testing of the optics for a 147-cm-aperture telescope

    NASA Technical Reports Server (NTRS)

    Buchroeder, R. A.; Elmore, L. H.; Shack, R. V.; Slater, P. N.

    1972-01-01

    Geodetic optics research for the Air Force Cambridge Research Laboratories (AFCRL) is described. The work consisted mainly of the fabrication of the optical components for a telescope with a 152-cm-diam (60-in.) primary mirror masked down to 147-cm-diam for use by the AFCRL for a lunar ranging experiment. Among the achievements of this contract were the following: completion of the primary and secondary mirrors for a high-quality 147-cm-diam telescope system in eight months from the start of edging the primary; manufacture and testing of a unique center mount for the primary according to an AFCRL design that allowed for a thin-edged and therefore less-massive mirror; and development of a quantitative analysis of the wire test for calculating the departure of the mirror figure from the design figure quickly and accurately after each polishing step. This analysis method in conjunction with a knowledge of polishing rates for given weights and diameters of tools, mirror, and polishing materials should considerably reduce the polishing time required for future large mirrors.

  6. Synchrotron/crystal sample preparation

    NASA Technical Reports Server (NTRS)

    Johnson, R. Barry

    1993-01-01

    The Center for Applied Optics (CAO) of the University of Alabama in Huntsville (UAH) prepared this final report entitled 'Synchrotron/Crystal Sample Preparation' in completion of contract NAS8-38609, Delivery Order No. 53. Hughes Danbury Optical Systems (HDOS) is manufacturing the Advanced X-ray Astrophysics Facility (AXAF) mirrors. These thin-walled, grazing incidence, Wolter Type-1 mirrors, varying in diameter from 1.2 to 0.68 meters, must be ground and polished using state-of-the-art techniques in order to prevent undue stress due to damage or the presence of crystals and inclusions. The effect of crystals on the polishing and grinding process must also be understood. This involves coating special samples of Zerodur and measuring the reflectivity of the coatings in a synchrotron system. In order to gain the understanding needed on the effect of the Zerodur crystals by the grinding and polishing process, UAH prepared glass samples by cutting, grinding, etching, and polishing as required to meet specifications for witness bars for synchrotron measurements and for investigations of crystals embedded in Zerodur. UAH then characterized these samples for subsurface damage and surface roughness and figure.

  7. Development of hybrid fluid jet/float polishing process

    NASA Astrophysics Data System (ADS)

    Beaucamp, Anthony T. H.; Namba, Yoshiharu; Freeman, Richard R.

    2013-09-01

    On one hand, the "float polishing" process consists of a tin lap having many concentric grooves, cut from a flat by single point diamond turning. This lap is rotated above a hydrostatic bearing spindle of high rigidity, damping and rotational accuracy. The optical surface thus floats above a thin layer of abrasive particles. But whilst surface texture can be smoothed to ~0.1nm rms (as measured by atomic force microscopy), this process can only be used on flat surfaces. On the other hand, the CNC "fluid jet polishing" process consists of pumping a mixture of water and abrasive particles to a converging nozzle, thus generating a polishing spot that can be moved along a tool path with tight track spacing. But whilst tool path feed can be moderated to ultra-precisely correct form error on freeform optical surfaces, surface finish improvement is generally limited to ~1.5nm rms (with fine abrasives). This paper reports on the development of a novel finishing method, that combines the advantages of "fluid jet polishing" (i.e. freeform corrective capability) with "float polishing" (i.e. super-smooth surface finish of 0.1nm rms or less). To come up with this new "hybrid" method, computational fluid dynamic modeling of both processes in COMSOL is being used to characterize abrasion conditions and adapt the process parameters of experimental fluid jet polishing equipment, including: (1) geometrical shape of nozzle, (2) position relative to the surface, (3) control of inlet pressure. This new process is aimed at finishing of next generation X-Ray / Gamma Ray focusing optics.

  8. Measurements of Raman crystallinity profiles in thin-film microcrystalline silicon solar cells

    NASA Astrophysics Data System (ADS)

    Choong, G.; Vallat-Sauvain, E.; Multone, X.; Fesquet, L.; Kroll, U.; Meier, J.

    2013-06-01

    Wedge-polished thin film microcrystalline silicon solar cells are prepared and used for micro-Raman measurements. Thereby, the variations of the Raman crystallinity with depth are accessed easily. Depth resolution limits of the measurement set-up are established and calculations evidencing the role of optical limits are presented. Due to this new technique, Raman crystallinity profiles of two microcrystalline silicon cells give first hints for the optimization of the profile leading to improved electrical performance of such devices.

  9. Influence of Deposition Conditions on Fatigue Properties of Martensitic Stainless Steel with Tin Film Coated by Arc Ion Plating Method

    NASA Astrophysics Data System (ADS)

    Fukui, Satoshi; Yonekura, Daisuke; Murakami, Ri-Ichi

    The surface properties like roughness etc. strongly influence the fatigue strength of high-tensile steel. To investigate the effect of surface condition and TiN coating on the fatigue strength of high-strength steel, four-point bending fatigue tests were carried out for martensitic stainless steel with TiN film coated using arc ion plating (AIP) method. This study, using samples that had been polished under several size of grind particle, examines the influence of pre-coating treatment on fatigue properties. A 2-µm-thick TiN film was deposited onto the substrate under three kinds of polishing condition. The difference of the hardness originated in the residual stress or thin deformation layer where the difference of the size of grinding particle of the surface polishing. And it leads the transformation of the interface of the substrate and the TiN film and improves fatigue limit.

  10. Highway pavement performance test for colored thin anti-skidding layers

    NASA Astrophysics Data System (ADS)

    Gao, Wei; Cui, Wei; Xu, Ming

    2018-03-01

    Based on the actual service condition of highway pavement colored thin anti-skidding layers, with materials of color quartz sand and two-component acrylic resin as basis, we designed such tests as the bond strength, shearing strength, tear strength, fatigue performance and aggregate polished value, and included the freeze-thaw cycle and de-icing salt and other factors in the experiment, connecting with the climate characteristics of circumpolar latitude and low altitude in Heilongjiang province. Through the pavement performance test, it is confirmed that the colored thin anti-skidding layers can adapt to cold and humid climate conditions, and its physical mechanical properties are good.

  11. Bias of air void system data from fly ash concretes.

    DOT National Transportation Integrated Search

    1983-01-01

    Hollow censopheres of fly ash may have walls so thin that they will appear to be air voids when they appear on a polished slab prepared for air void determination by ASTM C457. Therefore the following precautions are recommended. 1. The operator of t...

  12. Tailoring Thin Film-Lacquer Coatings for Space Application

    NASA Technical Reports Server (NTRS)

    Peters, Wanda C.; Harris, George; Miller, Grace; Petro, John

    1998-01-01

    Thin film coatings have the capability of obtaining a wide range of thermal radiative properties, but the development of thin film coatings can sometimes be difficult and costly when trying to achieve highly specular surfaces. Given any space mission's thermal control requirements, there is often a need for a variation of solar absorptance (Alpha(s)), emittance (epsilon) and/or highly specular surfaces. The utilization of thin film coatings is one process of choice for meeting challenging thermal control requirements because of its ability to provide a wide variety of Alpha(s)/epsilon ratios. Thin film coatings' radiative properties can be tailored to meet specific thermal control requirements through the use of different metals and the variation of dielectric layer thickness. Surface coatings can be spectrally selective to enhance radiative coupling and decoupling. The application of lacquer to a surface can also provide suitable specularity for thin film application without the cost and difficulty associated with polishing.

  13. Tailoring Thin Film-Lacquer Coatings for Space Applications

    NASA Technical Reports Server (NTRS)

    Peters, Wanda C.; Harris, George; Miller, Grace; Petro, John

    1998-01-01

    Thin film coatings have the capability of obtaining a wide range of thermal radiative properties, but the development of thin film coatings can sometimes be difficult and costly when trying to achieve highly specular surfaces. Given any space mission's then-nal control requirements, there is often a need for a variation of solar absorptance (alpha(sub s)), emittance (epsilon) and/or highly specular surfaces. The utilization of thin film coatings is one process of choice for meeting challenging thermal control requirements because of its ability to provide a wide variety of alpha(sub s)/epsilon ratios. Thin film coatings' radiative properties can be tailored to meet specific thermal control requirements through the use of different metals and the variation of dielectric layer thickness. Surface coatings can be spectrally selective to enhance radiative coupling and decoupling. The application of lacquer to a surface can also provide suitable specularity for thin film application without the cost and difficulty associated with polishing.

  14. Apparatus for sectioning demountable semiconductor samples

    DOEpatents

    Sopori, B.L.; Wolf, A.

    1984-01-01

    Apparatus for use during polishing and sectioning operations of a ribbon sample is described. The sample holder includes a cylinder having an axially extending sample cavity terminated in a first funnel-shaped opening and a second slot-like opening. A spring-loaded pressure plunger is located adjacent the second opening of the sample cavity for frictional engagement of the sample cavity. A heat softenable molding medium is inserted in the funnel-shaped opening, to surround the sample. After polishing, the heater is energized to allow draining of the molding medium from the sample cavity. During manual polishing, the second end of the sample holder is inserted in a support ring which provides mechanical support as well as alignment of the sample holder during polishing. A gauge block for measuring the protrusion of a sample beyond the second wall of the holder is also disclosed.

  15. Apparatus for sectioning demountable semiconductor samples

    DOEpatents

    Sopori, Bhushan L.; Wolf, Abraham

    1984-01-01

    Apparatus for use during polishing and sectioning operations of a ribbon sample is described. The sample holder includes a cylinder having an axially extending sample cavity terminated in a first funnel-shaped opening and a second slot-like opening. A spring-loaded pressure plunger is located adjacent the second opening of the sample cavity for frictional engagement of the sample prior to introduction of a molding medium in the sample cavity. A heat softenable molding medium is inserted in the funnel-shaped opening, to surround the sample. After polishing, the heater is energized to allow draining of the molding medium from the sample cavity. During manual polishing, the second end of the sample holder is inserted in a support ring which provides mechanical support as well as alignment of the sample holder during polishing. A gauge block for measuring the protrusion of a sample beyond the second wall of the holder is also disclosed.

  16. Thin Shell Manufacturing for large Wavefront correctors

    NASA Astrophysics Data System (ADS)

    Ruch, Eric; Poutriquet, Florence

    2011-09-01

    One of the major key elements in large adaptive optical systems is the thin shell, used as a deformable mirror. Although the optical prescriptions are relaxed with respect to a passive mirror, especially in the low spatial frequency domain, other requirements, such as the cosmetic defects (scratch & dig), the tight control of the thickness uniformity and of course the fragility of the piece having an aspect ratio up to 1000:1, generate new problems during the manufacturing, testing and handling of such optics. Moreover, the optical surface has to be tested in two different ways: a classical optical test bench allows us to create a surface map of the mirror. This map is then computed to determine the force required by the actuators to flatten the mirror and this becomes also a specification for polishing and implies a good interaction with the voice coil manufacturer. More than twenty years ago Sagem - Reosc developed the first meter class thin shell for early adaptive optics experiments. Since then, large thin shell have been used as the optical part in composite mirrors and more recently the aspheric shell for the VLT Deformable Secondary Mirror has been polished and prototypes, up to scale 1, of the E-ELT M4 Adaptive Mirror have been delivered to ESO in 2010. This paper will present some recent results in the manufacturing and testing technologies of large this shell, especially focusing on the development of the 1,1 meter convex aspherical shell for the VLT M2 mirror and on the results obtained on the largest thin shell produced so far (2,5 meter in diameter) developed as a demonstrator for the future E-ELT M4.

  17. Convenient mounting method for electrical measurements of thin samples

    NASA Technical Reports Server (NTRS)

    Matus, L. G.; Summers, R. L.

    1986-01-01

    A method for mounting thin samples for electrical measurements is described. The technique is based on a vacuum chuck concept in which the vacuum chuck simultaneously holds the sample and established electrical contact. The mounting plate is composed of a glass-ceramic insulating material and the surfaces of the plate and vacuum chuck are polished. The operation of the vacuum chuck is examined. The contacts on the sample and mounting plate, which are sputter-deposited through metal masks, are analyzed. The mounting method was utilized for van der Pauw measurements.

  18. Method for thinning specimen

    DOEpatents

    Follstaedt, David M.; Moran, Michael P.

    2005-03-15

    A method for thinning (such as in grinding and polishing) a material surface using an instrument means for moving an article with a discontinuous surface with an abrasive material dispersed between the material surface and the discontinuous surface where the discontinuous surface of the moving article provides an efficient means for maintaining contact of the abrasive with the material surface. When used to dimple specimens for microscopy analysis, a wheel with a surface that has been modified to produce a uniform or random discontinuous surface significantly improves the speed of the dimpling process without loss of quality of finish.

  19. Nanoleakage of dentin adhesive systems bonded to Carisolv-treated dentin.

    PubMed

    Kubo, Shisei; Li, Heping; Burrow, Michael F; Tyas, Martin J

    2002-01-01

    The hybrid layer created in caries-affected dentin has not been fully elucidated and may influence bond durability. This study investigated the nanoleakage patterns of caries-affected dentin after excavation with Carisolv or conventional instruments treated with one of three adhesive systems. Flat occlusal dentin surfaces, including carious lesions, were prepared from extracted human molars and finished with wet 600-grit silicon carbide paper. Carious dentin was removed with Carisolv or round steel burs in conjunction with Caries Detector. PermaQuik, Single Bond or One-Up Bond F was bonded to the excavated dentin surfaces and adjacent flat occlusal surfaces and it was covered with Silux Plus resin-based composite. After 24-hour storage in 37 degrees C water, the bonded interfaces were polished to remove flash, and the surrounding tooth surfaces were coated with nail varnish. Specimens were immersed in 50% (w/v) silver nitrate solution for 24 hours, exposed to photo developing solution for eight hours, then sectioned longitudinally through the bonded, excavated dentin or "normal" dentin surfaces. The sectioned surfaces were polished, carbon coated and observed in a Field Emission-SEM using back scattered electrons. Silver deposition occurred along the base of the hybrid layer for all specimens. However, Single Bond showed a greater density of silver deposition in the caries-affected dentin compared with normal dentin. PermaQuik had a thicker hybrid layer in caries-affected dentin than normal dentin. One-Up Bond F exhibited a thin hybrid layer in normal dentin, but the hybrid layer was often difficult to detect in caries-affected dentin.

  20. A study on the possibility of using nontextured polished substrates for longitudinal thin film recording media

    NASA Astrophysics Data System (ADS)

    Lo, Yu-Yun; Lin, Yusin; Chen, Chris C.; Wang, Chien-Min

    1999-04-01

    The use of NiAl seedlayer before depositing the underlayer on a (nontextured) polished substrate was studied. Same sputtering conditions were used on a (circumferentially) textured substrate for the purpose of comparison. The static magnetic properties measured by the vibrating sample magnetometer show very close Hc, Mrδ, and S* between them; and the magnetic recording performances measured by the Guzik tester show they are comparable. The "twice around modulation" verified by signal envelope test disappears on both of them. From this result, it is believed that the circumferential texturing is probably no longer needed when the NiAl seedlayer is added before depositing the underlayer.

  1. Method for atmospheric pressure reactive atom plasma processing for surface modification

    DOEpatents

    Carr, Jeffrey W [Livermore, CA

    2009-09-22

    Reactive atom plasma processing can be used to shape, polish, planarize and clean the surfaces of difficult materials with minimal subsurface damage. The apparatus and methods use a plasma torch, such as a conventional ICP torch. The workpiece and plasma torch are moved with respect to each other, whether by translating and/or rotating the workpiece, the plasma, or both. The plasma discharge from the torch can be used to shape, planarize, polish, and/or clean the surface of the workpiece, as well as to thin the workpiece. The processing may cause minimal or no damage to the workpiece underneath the surface, and may involve removing material from the surface of the workpiece.

  2. Design scheme for optical manufacturing support system of TMT M3 prototype

    NASA Astrophysics Data System (ADS)

    Hu, Haifei; Luo, Xiao

    2014-09-01

    Thirty Meter Telescope's Tertiary Mirror Cell Assembly (TMTM3-CA) will be manufactured in Changchun Institute of Optics, Fine Mechanics and Physics (CIOMP). To reduce the risk of fabricating TMTM3, a prototype made of Zerodur with a d/t ratio of 72 is planned to be polished. Here the focus is on the design scheme of the prototype's optical manufacturing support system. Firstly the number of support points was estimated, then structural design scheme for equal-force polishing support system are drawn, and finally layout optimization of support points was carried out. As its high performance and efficiency, the work will be beneficial to manufacturing large thin mirrors.

  3. Thin fused silica optics for a few arcsec angular resolution and large collecting area x-ray telescope

    NASA Astrophysics Data System (ADS)

    Citterio, O.; Civitani, M. M.; Pareschi, G.; Basso, S.; Campana, S.; Conconi, P.; Ghigo, M.; Mattaini, E.; Moretti, A.; Parodi, G.; Tagliaferri, G.

    2013-09-01

    The implementation of a X-ray mission with high imaging capabilities, similar to those achieved with Chandra (< 1 arcsec Half Energy Width, HEW), but with a much larger throughput is a very attractive perspective, even if challenging. For such a mission the scientific opportunities, in particular for the study of the early Universe, would remain at the state of the art for the next decades. At the beginning of the new millennium the XEUS mission has been proposed, with an effective area of several m2 and an angular resolution better than 2 arcsec HEW. Unfortunately, after the initial study, this mission was not implemented, mainly due to the costs and the low level of technology readiness. Currently the most advanced proposal for such a kind of mission is the SMART-X project, led by CfA and involving several other US Institutes. This project is based on adjustable segments of thin foil mirrors with piezo-electric actuators, aiming to achieve an effective area < 2 m2 at 1 keV and an angular resolution better than 1 arcsec HEW. Another attractive technology to realize an X-ray telescope with similar characteristics is being developed at NASA/Goddard. In this case the mirrors are based on Si substrates that are super-polished and figured starting from a bulky Si ingot, from which they are properly cut. Here we propose an alternative method based on precise direct grinding, figuring and polishing of thin (a few mm) glass shells with innovative deterministic polishing methods. This is followed by a final correction via ion figuring to obtain the desired accuracy in order to achieve the 1 arc sec HEW requirement. For this purpose, a temporary stiffening structure is used to support the shell from the polishing operations up to its integration in the telescope supporting structure. We will present the technological process under development, the results achieved so far and some mission scenarios based on this kind of optics, aiming to achieve an effective area more than 10 times larger than Chandra and an angular resolution of 1 arcsec HEW on axis and of a few arcsec off-axis across a large field of view (1 deg in diameter).

  4. Exploratory development and services for preparing and examining ultrathin polished sections of lunar rocks and particulates, part 1

    NASA Technical Reports Server (NTRS)

    Beauchamp, R. H.; Williford, J. F.; Gafford, E. L.

    1972-01-01

    Development of improved procedures is reported for three classes of lunar materials: dense rocks, breccias, and particulates. High quality ultrathin sections of these materials are obtained. Lists of equipment and supplies, procedures, photomicrographic documentation, and training are provided. Advantages of ultrathin polished sections for conventional and unconventional optical microscopy methods are described. Recommendations are provided for use of ultrathin sections in lunar rock studies, for further refinement of ultrathinning procedures, and for additional training efforts to establish a capability at the Manned Space Center. For Part 2, See N72-50754.

  5. 'Fluffy' Type A Ca-, Al-rich inclusions in the Allende meteorite

    NASA Technical Reports Server (NTRS)

    Macpherson, G. J.; Grossman, L.

    1984-01-01

    Inclusions called 'fluffy' Type A's or FTA's in the Allende meteorite are examined as possible candidates for relict vapor-solid condensate grains, remaining from the original solar nebula. Type A inclusions are characterized by abundant melilite and absence of primary anorthite and titaniferous pyroxene. Fluffy Type A's were probably loosely bound clumps of crystals drifting in the solar nebula, analogous to dustballs or snowflakes. Polished thin sections of all samples were studied optically and with a JEOL JSM-35 scanning electron microscope. It is reasonably clear that neither whole FTA's nor constituent nodules of the coarser grained ones were ever molten. Despite solid-state recrystallization which has affected these inclusions to varying degrees, the coarser grained material remaining in many of them is probably a relic of vapor-solid condensation in the solar nebula.

  6. Hierarchical super-structure identified by polarized light microscopy, electron microscopy and nanoindentation: Implications for the limits of biological control over the growth mode of abalone sea shells

    PubMed Central

    2012-01-01

    Background Mollusc shells are commonly investigated using high-resolution imaging techniques based on cryo-fixation. Less detailed information is available regarding the light-optical properties. Sea shells of Haliotis pulcherina were embedded for polishing in defined orientations in order to investigate the interface between prismatic calcite and nacreous aragonite by standard materialographic methods. A polished thin section of the interface was prepared with a defined thickness of 60 μm for quantitative birefringence analysis using polarized light and LC-PolScope microscopy. Scanning electron microscopy images were obtained for comparison. In order to study structural-mechanical relationships, nanoindentation experiments were performed. Results Incident light microscopy revealed a super-structure in semi-transparent regions of the polished cross-section under a defined angle. This super-structure is not visible in transmitted birefringence analysis due to the blurred polarization of small nacre platelets and numerous organic interfaces. The relative orientation and homogeneity of calcite prisms was directly identified, some of them with their optical axes exactly normal to the imaging plane. Co-oriented "prism colonies" were identified by polarized light analyses. The nacreous super-structure was also visualized by secondary electron imaging under defined angles. The domains of the super-structure were interpreted to consist of crystallographically aligned platelet stacks. Nanoindentation experiments showed that mechanical properties changed with the same periodicity as the domain size. Conclusions In this study, we have demonstrated that insights into the growth mechanisms of nacre can be obtained by conventional light-optical methods. For example, we observed super-structures formed by co-oriented nacre platelets as previously identified using X-ray Photo-electron Emission Microscopy (X-PEEM) [Gilbert et al., Journal of the American Chemical Society 2008, 130:17519–17527]. Polarized optical microscopy revealed unprecedented super-structures in the calcitic shell part. This bears, in principle, the potential for in vivo studies, which might be useful for investigating the growth modes of nacre and other shell types. PMID:22967319

  7. The diagnosis and management of food allergies. Position paper of the Food Allergy Section the Polish Society of Allergology

    PubMed Central

    Kaczmarski, Maciej; Czerwionka-Szaflarska, Mieczysława; Małaczyńska, Teresa; Krogulska, Aneta

    2017-01-01

    The paper concerns the current position of the Polish Society of Allergology Food Allergy Section on the diagnosis and management of food allergies. The aim of this position is to provide evidence-based recommendations on the diagnosis and management of patients with allergic hypersensitivity to foods. This position statement includes a systematic review of studies in three areas, namely, the epidemiology, diagnosis and management of food allergies. While taking into account the specific Polish setting, in this publication we also used the current European Academy of Allergy and Clinical Immunology (EAACI) position paper and other current position statements, including those of the United States National Institute of Allergy and Infectious Diseases (NIAID). PMID:29507553

  8. The diagnosis and management of food allergies. Position paper of the Food Allergy Section the Polish Society of Allergology.

    PubMed

    Bartuzi, Zbigniew; Kaczmarski, Maciej; Czerwionka-Szaflarska, Mieczysława; Małaczyńska, Teresa; Krogulska, Aneta

    2017-10-01

    The paper concerns the current position of the Polish Society of Allergology Food Allergy Section on the diagnosis and management of food allergies. The aim of this position is to provide evidence-based recommendations on the diagnosis and management of patients with allergic hypersensitivity to foods. This position statement includes a systematic review of studies in three areas, namely, the epidemiology, diagnosis and management of food allergies. While taking into account the specific Polish setting, in this publication we also used the current European Academy of Allergy and Clinical Immunology (EAACI) position paper and other current position statements, including those of the United States National Institute of Allergy and Infectious Diseases (NIAID).

  9. Multivariate Curve Resolution-Alternating Least Squares (MCR-ALS) with Raman Imaging Applied to Lunar Meteorites.

    PubMed

    Smith, Joseph P; Smith, Frank C; Booksh, Karl S

    2018-03-01

    Lunar meteorites provide a more random sampling of the surface of the Moon than do the returned lunar samples, and they provide valuable information to help estimate the chemical composition of the lunar crust, the lunar mantle, and the bulk Moon. As of July 2014, ∼96 lunar meteorites had been documented and ten of these are unbrecciated mare basalts. Using Raman imaging with multivariate curve resolution-alternating least squares (MCR-ALS), we investigated portions of polished thin sections of paired, unbrecciated, mare-basalt lunar meteorites that had been collected from the LaPaz Icefield (LAP) of Antarctica-LAP 02205 and LAP 04841. Polarized light microscopy displays that both meteorites are heterogeneous and consist of polydispersed sized and shaped particles of varying chemical composition. For two distinct probed areas within each meteorite, the individual chemical species and associated chemical maps were elucidated using MCR-ALS applied to Raman hyperspectral images. For LAP 02205, spatially and spectrally resolved clinopyroxene, ilmenite, substrate-adhesive epoxy, and diamond polish were observed within the probed areas. Similarly, for LAP 04841, spatially resolved chemical images with corresponding resolved Raman spectra of clinopyroxene, troilite, a high-temperature polymorph of anorthite, substrate-adhesive epoxy, and diamond polish were generated. In both LAP 02205 and LAP 04841, substrate-adhesive epoxy and diamond polish were more readily observed within fractures/veinlet features. Spectrally diverse clinopyroxenes were resolved in LAP 04841. Factors that allow these resolved clinopyroxenes to be differentiated include crystal orientation, spatially distinct chemical zoning of pyroxene crystals, and/or chemical and molecular composition. The minerals identified using this analytical methodology-clinopyroxene, anorthite, ilmenite, and troilite-are consistent with the results of previous studies of the two meteorites using electron microprobe analysis. To our knowledge, this is the first report of MCR-ALS with Raman imaging used for the investigation of both lunar and other types of meteorites. We have demonstrated the use of multivariate analysis methods, namely MCR-ALS, with Raman imaging to investigate heterogeneous lunar meteorites. Our analytical methodology can be used to elucidate the chemical, molecular, and structural characteristics of phases in a host of complex, heterogeneous geological, geochemical, and extraterrestrial materials.

  10. Characterization of Pu-238 Heat Source Granule Containment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Richardson, Paul Dean II; Sanchez, Joey Leo; Wall, Angelique Dinorah

    The Milliwatt Radioisotopic Themoelectric Generator (RTG) provides power for permissive-action links. Essentially these are nuclear batteries that convert thermal energy to electrical energy using a doped silicon-germanium thermopile. The thermal energy is provided by a heat source made of 238Pu, in the form of 238PuO 2 granules. The granules are contained by 3 layers of encapsulation. A thin T-111 liner surrounds the 238PuO 2 granules and protects the second layer (strength member) from exposure to the fuel granules. An outer layer of Hastalloy-C protects the T-111 from oxygen embrittlement. The T-111 strength member is considered the critical component in thismore » 238PuO 2 containment system. Any compromise in the strength member seen during destructive testing required by the RTG surveillance program is characterized. The T-111 strength member is characterized through Scanning Electron Microscopy (SEM), and Metallography. SEM is used in the Secondary Electron mode to reveal possible grain boundary deformation and/or cracking in the region of the strength member weld. Deformation and cracking uncovered by SEM are further characterized by Metallography. Metallography sections are mounted and polished, observed using optical microscopy, then documented in the form of microphotographs. SEM mat further be used to examine polished Metallography mounts to characterize elements using the SEM mode of Energy Dispersive X-ray spectroscopy (EDS).« less

  11. Laser polishing of additive manufactured Ti alloys

    NASA Astrophysics Data System (ADS)

    Ma, C. P.; Guan, Y. C.; Zhou, W.

    2017-06-01

    Laser-based additive manufacturing has attracted much attention as a promising 3D printing method for metallic components in recent years. However, surface roughness of additive manufactured components has been considered as a challenge to achieve high performance. In this work, we demonstrate the capability of fiber laser in polishing rough surface of additive manufactured Ti-based alloys as Ti-6Al-4V and TC11. Both as-received surface and laser-polished surfaces as well as cross-section subsurfaces were analyzed carefully by White-Light Interference, Confocal Microscope, Focus Ion Beam, Scanning Electron Microscopy, Energy Dispersive Spectrometer, and X-ray Diffraction. Results revealed that as-received Ti-based alloys with surface roughness more than 5 μm could be reduce to less than 1 μm through laser polishing process. Moreover, microstructure, microhardness and wear resistance of laser-polished zone was investigated in order to examine the thermal effect of laser polishing processing on the substrate of additive manufactured Ti alloys. This proof-of-concept process has the potential to effectively improve the surface roughness of additive manufactured metallic alloy by local polishing method without damage to the substrate.

  12. Uniform-load and actuator influence functions of a thin or thick annular mirror: application to active mirror support optimization

    NASA Astrophysics Data System (ADS)

    Arnold, Luc

    1996-03-01

    Explicit analytical expressions are derived for the elastic deformation of a thin or thick mirror of uniform thickness and with a central hole. Thin-plate theory is used to derive the general influence function, caused by uniform and/or discrete loads, for a mirror supported by discrete points. No symmetry considerations of the locations of the points constrain the model. An estimate of the effect of the shear forces is added to the previous pure bending model to take into account the effect of the mirror thickness. Two particular cases of general influence are the uniform-load (equivalent to gravity in the case of a thin mirror) influence function for a ring support of k discrete points with k-fold symmetry. The influence of the size of the support pads is studied. A method for optimizing an active mirror cell is presented that couples the minimization of the gravity influence function with the optimization of the combined actuator influence functions to fit low-order aberrations. These low-spatial-frequency aberrations can be of elastic or optical origin. In the latter case they are due, for example, to great residual polishing errors corresponding to the soft polishing specifications relaxed for cost reductions. Results show that the correction range of the active cell can thus be noticeably enlarged, compared with an active cell designed as a passive cell, i.e., by minimizing only the deflection under gravitational loading. In the example treated here of the European Southern Observatory's New Technology Telescope I show that the active correction range can be enlarged by approximately 50% in the case of third-order astigmatic correction.

  13. Sputtered Thin Film Research

    DTIC Science & Technology

    1974-11-01

    yield (100) oriented wafers, which were lapped and chemi-mechanically polished in sulf uric-peroxide or sodium hypochlorite etches. Prior to mounting...This material will viot oxidize, melt, or diffuse during the subsequent high temperature processing. Platinum silicide contacts are used because...formation of the platinum silicide contacts, the gate region was opened and the wafer was placed in the sput- tering chamber. The same deposition

  14. Additive manufactured x-ray optics for astronomy

    NASA Astrophysics Data System (ADS)

    Atkins, Carolyn; Feldman, Charlotte; Brooks, David; Watson, Stephen; Cochrane, William; Roulet, Melanie; Doel, Peter; Willingale, Richard; Hugot, Emmanuel

    2017-08-01

    Additive manufacturing, more commonly known as 3D printing, has become a commercially established technology for rapid prototyping and the fabrication of bespoke intricate parts. Optical components, such as mirrors and lenses, are now being fabricated via additive manufacturing, where the printed substrate is polished in a post-processing step. One application of additively manufactured optics could be within the astronomical X-ray community, where there is a growing need to demonstrate thin, lightweight, high precision optics for a beyond Chandra style mission. This paper will follow a proof-of-concept investigation, sponsored by the UK Space Agency's National Space Technology Programme, into the feasibility of applying additive manufacturing in the production of thin, lightweight, precision X-ray optics for astronomy. One of the benefits of additive manufacturing is the ability to construct intricate lightweighting, which can be optimised to minimise weight while ensuring rigidity. This concept of optimised lightweighting will be applied to a series of polished additively manufactured test samples and experimental data from these samples, including an assessment of the optical quality and the magnitude of any print-through, will be presented. In addition, the finite element analysis optimisations of the lightweighting development will be discussed.

  15. Section of Cybernetics in Mining of Mining Committee of Polish Academy of Sciences - Pro Memoria

    NASA Astrophysics Data System (ADS)

    Wojaczek, Antoni; Miśkiewicz, Kazimierz

    2017-09-01

    Section of Cybernetics in Mining of Mining Committee of Polish Academy of Science (PAN) has been created by PAN Mining Committee in 1969. It was a section in Mining Committee of PAN, whose operation range included widely understood issues of automation, telecommunication and informatics in mining industry. The main operation method of the Section was to organize the periodic conferences dedicated to issues of control systems in mining. The first conference took place in 1971 in Katowice. Together with new (the current one) term of office of Mining Committee of PAN this Section ceased to exist. The paper presents (pro memoria) over 40 year long conference output of this Section that functioned within the scope of operation of Mining Committee of PAN up to 12th January 2016.

  16. Controlled Bending of a Thin Mirror to Regain Figure after Warping due to Edge-Cutting

    NASA Astrophysics Data System (ADS)

    Humphries, C. M.

    1990-03-01

    A thin circular Cer-Vit mirror, diameter 1.3 m, that had been polished flat was cut along 10 edges to form a 12-sided pseudo-elliptical plate. As a result of the edge-cutting, the mirror distorted and an experiment that investigated the effect of reverse stressing to counteract the distortion is described and analysed. The configuration adopted for stressing the mirror when installed as a driven coudé flat in the UK Infrared Telescope is also described. The reverse stressing results can be understood in terms of thin plate theory for pure bending and, in general, if the distortion is toroidal (including the case of a sphere) an orthogonal pair of bending moments can be chosen that will remove the undesired curvatures.

  17. Design of a medium size x-ray mirror module based on thin glass foils

    NASA Astrophysics Data System (ADS)

    Basso, Stefano; Civitani, Marta; Pareschi, Giovanni

    2016-07-01

    The hot slumping glass technology for X-ray mirror is under development and in the last years the results have been improved. Nustar is the first X-ray telescope based on slumped glass foils and it benefit is the low cost compared to the direct polishing of glass. With the slumping technique it is possible to maintain the glass mass to low values with respect to the direct polishing, but in general the angular resolution is worst. A further technique based on glass is the cold shaping of foils. The improved capabilities of manufacturing thin glass foils, pushed by the industrial application for screens, open new possibilities for X-ray mirror. The increase in strength of thin tempered glasses, the reduction of thickness errors and the good roughness of flat foils are potentially great advantages. In this paper a design of a mediumsize X-ray mirror module is analysed. It is based on integration of glass foils, stacked directly on a supporting structure that is part of the X-ray telescope using stiffening ribs as spacer between foils. The alignment of each stack is performed directly into the integration machine avoiding the necessity of the alignment of different stacked modules. A typical module (glass optic and metallic structure) provides an effective area of 10 cm2/kg at 1 keV (with a mass of about 50- 100 kg and a focal length of 10 m).

  18. Late Maastrichtian foraminiferids and diatoms from the Polish Carpathians (Ropianka Formation, Skole Nappe): a case study from the Chmielnik-Grabówka composite section

    NASA Astrophysics Data System (ADS)

    Gasiński, M. Adam; Olshtynska, Alexandra; Uchman, Alfred

    2013-12-01

    Gasiński, M.A., Olshtynska, A. and Uchman, A. 2013. Late Maastrichtian foraminiferids and diatoms from the Polish Carpathians (Ropianka Formation, Skole Nappe): a case study from the Chmielnik-Grabowka composite section. Acta Geologica Polonica, 63(4), 515-525. Warszawa. Well-preserved foraminiferids have been found in the Chmielnik-Grabowka section (Skole Nappe, Polish Carpathians). The Abathomphalus mayaroensis (late Maastrichtian) and Racemiguembelina fructicosa (earlylate Maastrichtian) standard planktonic foraminiferal biozones have been recognized, based on the occurrence of their respective index species. Sediments of the R. fructicosa Zone contain diatoms, which are a rare component of Cretaceous flysch microfossil assemblages in the Carpathians. The diatom frustules and some foraminiferid tests are pyritized, probably after burial in the sediment, below the redox boundary or in the oxygen- deficient microenvironment inside the frustules or tests of microfossils; the presence of trace fossils and bioturbational structures in the same bed indicate an oxygenated sea floor.

  19. Investigation of contact pressure and influence function model for soft wheel polishing.

    PubMed

    Rao, Zhimin; Guo, Bing; Zhao, Qingliang

    2015-09-20

    The tool influence function (TIF) is critical for calculating the dwell-time map to improve form accuracy. We present the TIF for the process of computer-controlled polishing with a soft polishing wheel. In this paper, the static TIF was developed based on the Preston equation. The pressure distribution was verified by the real removal spot section profiles. According to the experiment measurements, the pressure distribution simulated by Hertz contact theory was much larger than the real contact pressure. The simulated pressure distribution, which was modeled by the Winkler elastic foundation for a soft polishing wheel, matched the real contact pressure. A series of experiments was conducted to obtain the removal spot statistical properties for validating the relationship between material removal and processing time and contact pressure and relative velocity, along with calculating the fitted parameters to establish the TIF. The developed TIF predicted the removal character for the studied soft wheel polishing.

  20. Pulsed laser deposited ZnO film on side-polished fiber as a gas sensing element.

    PubMed

    Dikovska, Anna Og; Atanasov, Petar A; Stoyanchov, Toshko R; Andreev, Andrey T; Karakoleva, Elka I; Zafirova, Blagovesta S

    2007-05-01

    A simple sensor element consisting of a side-polished single-mode fiber and a planar metal oxide waveguide is described. The thin ZnO planar waveguide was produced on the polished fiber surface by pulsed laser deposition at optimized processing parameters. A measurement scheme for in situ control of the film thickness during the deposition process was developed and used. X-ray diffraction measurements and scanning electron microscopy were used to characterize the structure and the surface morphology of the planar waveguide, respectively. The numerical evaluation of the sensor sensitivity predicts the possibility to detect refractive index changes of less than 10(-4). Furthermore, preliminary gas sensor tests were performed by using a mixture of 1.5% butane diluted in N(2) and pure butane. A shift of the spectral position of the resonance points was observed from 3 to 5 s after gas exposure, which corresponds to refractive index changes of 3 x 10(-5) and 1.2 x 10(-3) for 1.5% butane and for pure butane, respectively.

  1. Coaxial line configuration for microwave power transmission study of YBa2Cu3O(7-delta) thin films

    NASA Technical Reports Server (NTRS)

    Chorey, C. M.; Miranda, F. A.; Bhasin, K. B.

    1991-01-01

    Microwave transmission measurements through YBa2Cu3O(7-delta) (YBCO) high-transition-temperature superconducting thin films on lanthanum aluminate (LaAlO3) have been performed in a coaxial line at 10 GHz. LaAlO3 substrates were ultrasonically machined into washer-shaped discs, polished, and coated with laser-ablated YBCO. These samples were mounted in a 50-ohm coaxial air line to form a short circuit. The power transmitted through the films as a function of temperature was used to calculate the normal state conductivity and the magnetic penetration depth for the films.

  2. Gloss and Stain Resistance of Ceramic-Polymer CAD/CAM Restorative Blocks.

    PubMed

    Lawson, Nathaniel C; Burgess, John O

    2016-03-01

    To evaluate the gloss and stain resistance of several new ceramic-polymer CAD/CAM blocks Specimens (4 mm) were sectioned from: Enamic (polymer-infused ceramic), LAVA Ultimate (nano-ceramic reinforced polymer), e.max (lithium disilicate), Paradigm C (porcelain), and Paradigm MZ100 (composite). Specimens were wet polished on a polishing wheel to either 320 grit silicon paper (un-polished, N = 8) or 2000 grit silicon carbide papers followed by a 0.05 μm alumina slurry (polished, N = 8). Initial gloss and color (L*a*b*) values were measured. Specimens were stored in a staining solution at 37°C in darkness for 12 days (simulating 1 year). After storage, L*a*b* values re-measured. Change in color was reported as ΔE00 based on the CIEDE2000 formula. Gloss and ΔE00 were analyzed by two-way analysis of variance (ANOVA) (alpha = .05). Separate one-way ANOVA and Tukey post-hoc analyses were performed for both polish conditions and all materials. Two-way ANOVA showed that factors material, polish and their interaction were significant for both gloss and ΔE00 (p < .01). Post-hoc analysis reveals that polished specimens had significantly less color change than un-polished specimens for Paradigm C and LAVA Ultimate. E.max had significantly higher gloss and less color change than all other materials. The composition and polish of CAD/CAM materials affects gloss and stain resistance. Ceramic-polymer hybrid materials can achieve the high gloss required for esthetic restorations. These materials should be polished in order to minimize staining. If polished, all of the tested materials exhibited clinically acceptable color changes at 1 year of simulated staining. (J Esthet Restor Dent 28:S40-S45, 2016). © 2015 Wiley Periodicals, Inc.

  3. LIGO optics manufacture: figuring transmission core optics for best performance

    NASA Astrophysics Data System (ADS)

    Leistner, Achim J.; Farrant, David I.; Oreb, Bozenko F.; Pavlovic, Edita; Seckold, Jeffrey A.; Walsh, Christopher J.

    1999-11-01

    The Laser Interferometer Gravitational-wave Observatory (LIGO) is a long baseline Michelson interferometer, with arms of up to 4 km in length each containing a Fabry Perot cavity. CSIRO has manufactured 32 core optical components for the LIGO interferometer consisting of five different groups of optical elements. Long radii of curvature (7 km - 15 km) and tolerances in the order of plus or minus 200 m in the radius are specified. Although the components are made of hyper pure fused silica there are some residual inhomogeneities in the material. The optics used in transmission must be figured so that the influence of these material inhomogeneities on the transmitted wave front is compensated for. This was done by correcting the surface figure on side 2 of the optics. The approach we took to manufacturing the transmission optics was to calculate the quadratic component of refractive index gradient (Delta) n of the substrate from the measurements of the transmitted wavefront and the surface profile of the two substrate surfaces, determine what shape had to be produced on side two of the substrates to compensate for this gradient and then produce this by optical polishing. The surfaces were polished on rigid solid laps of Zerodur coated with a thin layer of Teflon as the polishing matrix, a technique developed by CSIRO for super-polishing very flat surfaces.

  4. Structural Health Monitoring 2007: Quantification, Validation, and Implementation

    DTIC Science & Technology

    2007-11-30

    11:20 ~ 11:40 A Novel MEMS Strain Sensor for Structural Health Monitoring Applications under Harsh Environmental Conditions p. 121 Matthew Malkin...Session: Wave Propagation Models in Damage Assesment Chair: Wieslaw Ostachowicz, Polish Academy of Sciences Room: 030 W. Ostachowicz and P. Kudela...University Dayton Research Institute 11:00 ~ 11:20 Low Impact Damage Detection and Analysis with Thin Film Piezo-electric Sensors p. 1064 Samuel

  5. Stress polishing of thin shells for adaptive secondary mirrors. Application to the Very Large Telescope deformable secondary

    NASA Astrophysics Data System (ADS)

    Hugot, E.; Ferrari, M.; Riccardi, A.; Xompero, M.; Lemaître, G. R.; Arsenault, R.; Hubin, N.

    2011-03-01

    Context. Adaptive secondary mirrors (ASM) are, or will be, key components on all modern telescopes, providing improved seeing conditions or diffraction limited images, thanks to the high-order atmospheric turbulence correction obtained by controlling the shape of a thin mirror. Their development is a key milestone towards future extremely large telescopes (ELT) where this technology is mandatory for successful observations. Aims: The key point of actual adaptive secondaries technology is the thin glass mirror that acts as a deformable membrane, often aspheric. On 6 m - 8 m class telescopes, these are typically 1 m-class with a 2 mm thickness. The optical quality of this shell must be sufficiently good not to degrade the correction, meaning that high spatial frequency errors must be avoided. The innovative method presented here aims at generating aspherical shapes by elastic bending to reach high optical qualities. Methods: This method is called stress polishing and allows generating aspherical optics of a large amplitude with a simple spherical polishing with a full sized lap applied on a warped blank. The main advantage of this technique is the smooth optical quality obtained, free of high spatial frequency ripples as they are classically caused by subaperture toolmarks. After describing the manufacturing process we developed, our analytical calculations lead to a preliminary definition of the geometry of the blank, which allows a precise bending of the substrate. The finite element analysis (FEA) can be performed to refine this geometry by using an iterative method with a criterion based on the power spectral density of the displacement map of the optical surface. Results: Considering the specific case of the Very Large Telescope (VLT) deformable secondary mirror (DSM), extensive FEA were performed for the optimisation of the geometry. Results are showing that the warping will not introduce surface errors higher than 0.3 nm rms on the minimal spatial scale considered on the mirror. Simulations of the flattening operation of the shell also demonstrate that the actuators system is able to correct manufacturing surface errors coming from the warping of the blank with a residual error lower than 8 nm rms.

  6. Otolith Trace Element Chemistry of Juvenile Black Rockfish

    NASA Astrophysics Data System (ADS)

    Hardin, W.; Bobko, S. J.; Jones, C. M.

    2002-12-01

    In the summer of 1997 we collected young-of -the-year (YOY) black rockfish, Sebastes melanops, from floating docks and seagrass beds in Newport and Coos Bay, Oregon. Otoliths were extracted from randomly selected fish, sectioned and polished under general laboratory conditions, and cleaned in a class 100 clean room. We used Laser Ablation - Inductively Coupled Mass Spectrometry (LA-ICPMS) to analyze elemental composition of the estuarine phase of the otoliths. While we observed differences in Mn/Ca ratios between the two estuaries, there was no statistical difference in otolith trace element chemistry ratios between estuaries using MANOVA. To determine if laboratory processing of otoliths might have impeded us from detecting differences in otolith chemistry, we conducted a second experiment. Right and left otoliths from 10 additional Coos Bay fish were randomly allocated to two processing methods. The first method was identical to our initial otolith processing, sectioning and polishing under normal laboratory conditions. In the second method, polishing was done in the clean room. For both methods otoliths went through a final cleaning in the clean room and analyzed with LA-ICPMS. While we did not detect statistical differences in element ratios between the two methods, otoliths polished outside the clean room had much higher variances. This increased variance might have lowered our ability to detect differences in otolith chemistry between estuaries. Based on our results, we recommend polishing otoliths under clean room conditions to reduce contamination.

  7. Rapid Determination of Mineral Abundance by X-ray Microfluorescence Mapping and Multispectral Image Analysis

    NASA Astrophysics Data System (ADS)

    Moscati, R. J.; Marshall, B. D.

    2005-12-01

    X-ray microfluorescence (XRMF) spectrometry is a rapid, accurate technique to map element abundances of rock surfaces (such as thin-section billets, the block remaining when a thin section is prepared). Scanning a specimen with a collimated primary X-ray beam (100 μm diameter) generates characteristic secondary X-rays that yield the relative chemical abundances for the major rock-/mineral-forming analytes (such as Si, Al, K, Ca, and Fe). When Cu-rich epoxy is used to impregnate billets, XRMF also can determine porosity from the Cu abundance. Common billet scan size is 30 x 15 mm and the typical mapping time rarely exceeds 2.5 hrs (much faster than traditional point-counting). No polishing or coating is required for the billets, although removing coarse striations or gross irregularities on billet surfaces should improve the spatial accuracy of the maps. Background counts, spectral artifacts, and diffraction peaks typically are inconsequential for maps of major elements. An operational check is performed after every 10 analyses on a standard that contains precisely measured areas of Mn and Mo. Reproducibility of the calculated area ratio of Mn:Mo is consistently within 5% of the known value. For each billet, the single element maps (TIFF files) generated by XRMF are imported into MultiSpec© (a program developed at Purdue University for analysis of multispectral image data, available from http://dynamo.ecn.purdue.edu/~biehl/MultiSpec/) where mineral phases can be spectrally identified and their relative abundances quantified. The element maps for each billet are layered to produce a multi-element file for mineral classification and statistical processing, including modal estimates of mineral abundance. Although mineral identification is possible even if the mineralogy is unknown, prior petrographic examination of the corresponding thin section yields more accurate maps because the software can be set to identify all similar pixels. Caution is needed when using MultiSpec© to distinguish mineral phases with similar chemistry (for example, opal and quartz) and minerals that occupy very small surface areas (<10 pixels). In either case, careful petrography and informed use of the software will allow rapid use of MultiSpec© to create accurate mineral maps of rock and thin-section billet surfaces. This technique, for example, has allowed quantitative estimates of calcite and silica abundances to be determined on about 200 samples of secondary mineral coatings from the unsaturated zone at Yucca Mountain, Nevada.

  8. Gemini 8.2-m primary mirror no. 1 polishing

    NASA Astrophysics Data System (ADS)

    Cayrel, Marc; Beraud, P.; Paseri, Jacques; Dromas, E.

    1998-08-01

    The 8-m class primary mirrors of the GEMINI Telescopes are thin ULE menisci actively supported. The two mirror blanks are produced by CORNING, the optical figuring, manufacturing and assembling of interfaces are done by REOSC. REOSC is as well in charge of the transportation of the mirror blanks from CORNING to REOSC, and of the shipment of the finished optics to Hawaii and to Chile. The mirror assembly requirements are summarized, the manufacturing and testing methods are addressed. REOSC had to design and manufacture a dedicated active supporting system, representative of the one used at the telescope level. Its design and performance are presented. The manufacturing steps undertaken at REOSC and the results achieved are then detailed: mirror blank surface generating and grinding, polishing, testing. The current status of the mirrors is finally presented.

  9. Predicting Print-thru for the Sub-scale Beryllium Mirror Demonstrator (SBMD)

    NASA Technical Reports Server (NTRS)

    Craig, Larry; J. Kevin Russell (Technical Monitor)

    2002-01-01

    This document presents a finite element method for predicting print-thru or quilting for a lightweight mirror in a low temperature environment. The mirror is represented with quadrilateral and triangular plate finite elements. The SBMD (Sub-scale Beryllium Mirror Demonstrator) is circular with a diameter of 50 cm and one flat side. The mirror structure is a thin-wall triangular cell core with a single facesheet. There is a 4 mm radius fillet between the facesheet and cell walls. It is made entirely of Beryllium. It is assumed that polishing the mirror surface creates a thin surface layer with different material properties. Finite element results are compared with measured values at cryogenic temperatures.

  10. Thin coatings for protecting titanium aluminides in high-temperature oxidizing environments

    NASA Technical Reports Server (NTRS)

    Wiedemann, K. E.; Taylor, P. J.; Clark, R. K.; Wallace, T. A.

    1991-01-01

    Titanium aluminides have high specific strengths at high temperatures but are susceptible to environmental attack. Their use in many aerospace applications would require that they be protected with coatings that, for structural efficiency, must be thin. It is conceivable that acceptable coatings might be found in several oxide systems, and consequently, oxide coatings of many compositions were prepared from sol-gels for study. Response-surface methodology was used to refine coating compositions and factorial experiments were used to develop coating strategies. Oxygen permeability diagrams of two-layer coatings for several oxide systems, an analysis of multiple-layer coatings on rough and polished surfaces, and modeling of the oxidation weight gain are presented.

  11. Measured reflectance suppressed by thin-film interference of crude oil smeared on glass - as on vitrinite in coal or petroliferous rocks

    USGS Publications Warehouse

    Bostick, Neely

    2011-01-01

    The tool of measuring "vitrinite reflectance" under a microscope has great value in petroleum exploration and coal utilization, and the reflectance is a simple number, such as 1.4% Ro, with some slight variations depending on technique. Sample collection, preparation and measurement are simple and many sedimentary rocks yield vitrinite. However, the reported number can lead one astray if its origin and quality are not fully understood. I analyze here just one factor, "smear" of crude oil on the polished surface (from the sample), which may reduce reflectance because of thin-film interference. Some other causes of error are listed in an addendum to this note.

  12. Metallographic techniques for evaluation of thermal barrier coatings

    NASA Technical Reports Server (NTRS)

    Brindley, William J.; Leonhardt, Todd A.

    1990-01-01

    The performance of ceramic thermal barrier coatings is strongly dependent on the amount and shape of the porosity in the coating. Current metallographic techniques do not provide polished surfaces that are adequate for a repeatable interpretation of the coating structures. A technique recently developed at NASA-Lewis for preparation of thermal barrier coating sections combines epoxy impregnation, careful sectioning and polishing, and interference layering to provide previously unobtainable information on processing-induced porosity. In fact, increased contrast and less ambiguous structure developed by the method make automatic quantitative metallography a viable option for characterizing thermal barrier coating structures.

  13. Atopic dermatitis: current treatment guidelines. Statement of the experts of the Dermatological Section, Polish Society of Allergology, and the Allergology Section, Polish Society of Dermatology.

    PubMed

    Nowicki, Roman; Trzeciak, Magdalena; Wilkowska, Aleksandra; Sokołowska-Wojdyło, Małgorzata; Ługowska-Umer, Hanna; Barańska-Rybak, Wioletta; Kaczmarski, Maciej; Kowalewski, Cezary; Kruszewski, Jerzy; Maj, Joanna; Silny, Wojciech; Śpiewak, Radosław; Petranyuk, Andriy

    2015-08-01

    Atopic dermatitis (AD) is a condition frequently encountered in medical practices across the country. More than 60% of children with AD are at risk to develop allergic rhinitis or asthma (the atopic march). Patients with AD have a unique predisposition to colonization or infection by Staphylococcus aureus. Treatments for AD need to rapidly control symptoms of the disease, improve quality of life and prevent exacerbations. Given the chronic and relapsing nature of the disease, therapies need to encourage good compliance and be well tolerated.

  14. Plasma etching a ceramic composite. [evaluating microstructure

    NASA Technical Reports Server (NTRS)

    Hull, David R.; Leonhardt, Todd A.; Sanders, William A.

    1992-01-01

    Plasma etching is found to be a superior metallographic technique for evaluating the microstructure of a ceramic matrix composite. The ceramic composite studied is composed of silicon carbide whiskers (SiC(sub W)) in a matrix of silicon nitride (Si3N4), glass, and pores. All four constituents are important in evaluating the microstructure of the composite. Conventionally prepared samples, both as-polished or polished and etched with molten salt, do not allow all four constituents to be observed in one specimen. As-polished specimens allow examination of the glass phase and porosity, while molten salt etching reveals the Si3N4 grain size by removing the glass phase. However, the latter obscures the porosity. Neither technique allows the SiC(sub W) to be distinguished from the Si3N4. Plasma etching with CF4 + 4 percent O2 selectively attacks the Si3N4 grains, leaving SiC(sub W) and glass in relief, while not disturbing the pores. An artifact of the plasma etching reaction is the deposition of a thin layer of carbon on Si3N4, allowing Si3N4 grains to be distinguished from SiC(sub W) by back scattered electron imaging.

  15. Large magnetization and high Curie temperature in highly disordered nanoscale Fe2CrAl thin films

    NASA Astrophysics Data System (ADS)

    Dulal, Rajendra P.; Dahal, Bishnu R.; Forbes, Andrew; Pegg, Ian L.; Philip, John

    2017-02-01

    We have successfully grown nanoscale Fe2CrAl thin films on polished Si/SiO2 substrates using an ultra-high vacuum deposition with a base pressure of 9×10-10 Torr. The thickness of thin films ranges from 30 to 100 nm. These films exhibit cubic crystal structure with lattice disorder and display ferromagnetic behavior. The Curie temperature is greater than 400 K, which is much higher than that reported for bulk Fe2CrAl. The magnetic moments of the films varies from 2.5 to 2.8 μB per formula unit, which is larger than the reported bulk values. Thus, the disordered nanoscale Fe2CrAl films exhibit strong Fe-Fe exchange interactions through Fe-Cr-Fe and Fe-Al-Fe layers, resulting in both a large magnetization and a high Curie temperature.

  16. Effects of finishing/polishing techniques on microleakage of resin-modified glass ilonomer cement restorations.

    PubMed

    Yap, Adrian U J; Yap, W Y; Yeo, Egwin J C; Tan, Jane W S; Ong, Debbie S B

    2003-01-01

    This study investigated the effect of finishing/polishing techniques on the microleakage of resin-modified glass ionomer restorations. Class V preparations were made on the buccal and lingual/palatal surfaces of freshly extracted teeth. The cavities on each tooth were restored with Fuji II LC (FT [GC]) and Photac-Fil Quick (PF [3M-ESPE]) according to manufacturers' instructions. Immediately after light-polymerization, gross finishing was done with eight-fluted tungsten carbide burs. The teeth were then randomly divided into four groups and finishing/polishing was done with one of the following systems: (a) Robot Carbides (RC); (b) Super-Snap system (SS); (c) OneGloss (OG) and (d) CompoSite Polishers (CS). The sample size for each material-finishing/polishing system combination was eight. After finishing/polishing, the teeth were stored in distilled water at 37 degrees C for one week. The root apices were then sealed with acrylic and two coats of varnish was applied 1 mm beyond the restoration margins. The teeth were subsequently subjected to dye penetration testing (0.5% basic fuchsin), sectioned and scored. Data was analyzed using Kruskal-Wallis and Mann-Whitney U tests at a significance level of 0.05. Results of statistical analysis were as follows: Enamel margins: PF-OG

  17. Application of Nomarski DIC and cathodoluminescence (CL) microscopy to building materials

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Goetze, J., E-mail: goetze@mineral.tu-freiberg.de

    2009-07-15

    The present study discusses the potential of an integrated application of Nomarski differential interference contrast and cathodoluminescence microscopy for the investigation of building materials such as natural stone, cement, mortar and concrete. Nomarski differential interference contrast microscopy is a modern technique applied in materials sciences to visualize different phases and/or to image the surface relief on the scale of 50 nm. It is based on the principle of beam splitting by a double-crystal prism split, resulting in the superposition of laterally shifted wave fronts. In cathodoluminescence microscopy, the luminescence signal is excited by an electron beam and is generated bymore » different point defects within the material. Therefore, cathodoluminescence is a powerful method to characterize the defect structure of solid materials, to distinguish different phases and to reveal detailed information about their chemical composition. By combining Nomarski differential interference contrast and cathodoluminescence microscopy, textural, crystallographic and chemical information can be obtained from the same sample area in a polished thin section.« less

  18. Structural and Electronic Properties Study of Colombian Aurifer Soils by Mössbauer Spectroscopy and X-ray Diffraction

    NASA Astrophysics Data System (ADS)

    Bustos Rodríguez, H.; Rojas Martínez, Y.; Oyola Lozano, D.; Pérez Alcázar, G. A.; Fajardo, M.; Mojica, J.; Molano, Y. J. C.

    2005-02-01

    In this work a study on gold mineral samples is reported, using optical microscopy, X-ray diffraction (XRD) and Mössbauer spectroscopy (MS). The auriferous samples are from the El Diamante mine, located in Guachavez-Nariño (Colombia) and were prepared by means of polished thin sections. The petrography analysis registered the presence, in different percentages that depend on the sample, of pyrite, quartz, arsenopyirite, sphalerite, chalcopyrite and galena. The XRD analysis confirmed these findings through the calculated cell parameters. One typical Rietveld analysis showed the following weight percent of phases: 85.0% quartz, 14.5% pyrite and 0.5% sphalerite. In this sample, MS demonstrated the presence of two types of pyrite whose hyperfine parameters are δ 1 = 0.280 ± 0.002 mm/s and Δ 1 = 0.642 ± 0.002 mm/s, δ 2 = 0.379 ± 0.002 mm/s and Δ 2 = 0.613 ± 0.002 mm/s.

  19. REE compositions in fossil vertebrate dental tissues indicate biomineral preservation

    NASA Astrophysics Data System (ADS)

    Žigaite, Ž.; Kear, B.; Pérez-Huerta, A.; Jeffries, T.; Blom, H.

    2012-04-01

    Rare earth element (REE) abundances have been measured in a number of Palaeozoic and Mesozoic dental tissues using Laser Ablation Inductively Coupled Plasma Mass-spectrometry (LA-ICP-MS). Fossil vertebrates analysed comprise scales and tesserae of Silurian and Devonian acanthodians, chondrichthyans, galeaspids, mongolepids, thelodonts, as well as teeth of Cretaceous lungfish and marine reptiles. The evaluation of fossil preservation level has been made by semi-quantitative spot geochemistry analyses on fine polished teeth and scale thin sections, using Energy Dispersive X-ray Spectroscopy (EDS). Fossil teeth and scales with significant structure and colour alteration have shown elevated heavy element concentrations, and the silicification of bioapatite has been common in their tissues. Stable oxygen isotope measurements (δ18O) of bulk biomineral have been conducted in parallel, and showed comparatively lower heavy oxygen values in the same fossil tissues with stronger visible alteration. Significant difference in REE concentrations has been observed between the dentine and enamel of Cretaceous plesiosaurs, suggesting the enamel to be more geochemically resistant to diagenetic overprint.

  20. The effect of photo-activated glazes on the microhardness of acrylic baseplate resins.

    PubMed

    Emmanouil, J K; Kavouras, P; Kehagias, Th

    2002-01-01

    A comparative investigation of acrylic denture base surface microhardness, induced through glazing with different photo-activated liquids. Thermopolymerized acrylic resin Paladon 65 (Kulzer) was used for this study. The samples were mechanically thinned by silicon carbide grinding papers and finally, mechanically polished by alumina pastes. The samples were then glazed with Palaseal, Plaquit and Lightplast-Lack photo-activated liquids. Microhardness tests were carried out via a Zeiss optical microscope equipped with an Anton Paar microhardness tester fitted with a Knoop indenter. Microhardness testing performed on surfaces glazed by Plaquit, Lightplast-Lack, and Palaseal photo-activated liquids showed enhanced microhardness values compared to the mechanically polished acrylic resin denture base material. Comparative microhardness tests performed on acrylic base resin treated with photo-activated acrylic glazes showed that all increases the surface microhardness. The enhancement of surface microhardness of acrylic denture bases suggests that they are likely to resist wear during service.

  1. Constitutive law for the densification of fused silica with applications in polishing and microgrinding

    NASA Astrophysics Data System (ADS)

    Lambropoulos, John C.; Fang, Tong; Xu, Su; Gracewski, Sheryl M.

    1995-09-01

    We discuss a constitutive model describing the permanent densification of fused silica under large applied pressures and shear stresses. The constitutive law is assumed to be rate- independent, and uses a yield function coupling hydrostatic pressure and shear stress, a flow rule describing the evolution of permanent strains after initial densification, and a hardening rule describing the dependence of the incremental densification on the levels of applied stresses. The constitutive law accounts for multiaxial states of stress, since during polishing and grinding operations complex stress states occur in a thin surface layer due to the action of abrasive particles. Due to frictional and other abrasive forces, large shear stresses are present near the surface during manufacturing. We apply the constitutive law in estimating the extent of the densified layer during the mechanical interaction of an abrasive grain and a flat surface.

  2. Low-cost rapid miniature optical pressure sensors for blast wave measurements.

    PubMed

    Wu, Nan; Wang, Wenhui; Tian, Ye; Zou, Xiaotian; Maffeo, Michael; Niezrecki, Christopher; Chen, Julie; Wang, Xingwei

    2011-05-23

    This paper presents an optical pressure sensor based on a Fabry-Perot (FP) interferometer formed by a 45° angle polished single mode fiber and an external silicon nitride diaphragm. The sensor is comprised of two V-shape grooves with different widths on a silicon chip, a silicon nitride diaphragm released on the surface of the wider V-groove, and a 45° angle polished single mode fiber. The sensor is especially suitable for blast wave measurements: its compact structure ensures a high spatial resolution; its thin diaphragm based design and the optical demodulation scheme allow a fast response to the rapid changing signals experienced during blast events. The sensor shows linearity with the correlation coefficient of 0.9999 as well as a hysteresis of less than 0.3%. The shock tube test demonstrated that the sensor has a rise time of less than 2 µs from 0 kPa to 140 kPa.

  3. Characterization of Pu-238 heat source granule containment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Richardson Ii, P D; Thronas, D L; Romero, J P

    2008-01-01

    The Milliwatt Radioisotopic Thermoelectric Generator (RTG) provides power for permissive-action links. These nuclear batteries convert thermal energy to electrical energy using a doped silicon-germanium thermopile. The thermal energy is provided by a heat source made of {sup 238}Pu, in the form of {sup 238}PuO{sub 2} granules. The granules are contained in 3 layers of encapsulation. A thin T-111 liner surrounds the {sup 238}PuO{sub 2} granules and protects the second layer (strength member) from exposure to the fuel granules. The T-111 strength member contains the fuel under impact condition. An outer clad of Hastelloy-C protects the T-111 from oxygen embrittlement. Themore » T-111 strength member is considered the critical component in this {sup 238}PuO{sub 2} containment system. Any compromise in the strength member is something that needs to be characterized. Consequently, the T-111 strength member is characterized upon it's decommissioning through Scanning Electron Microscopy (SEM), and Metallography. SEM is used in Secondary Electron mode to reveal possible grain boundary deformation and/or cracking in the region of the strength member weld. Deformation and cracking uncovered by SEM are further characterized by Metallography. Metallography sections are mounted and polished, observed using optical microscopy, then documented in the form of photomicrographs. SEM may further be used to examine polished Metallography mounts to characterize elements using the SEM mode of Energy Dispersive X-ray Spectroscopy (EDS). This paper describes the characterization of the metallurgical condition of decommissioned RTG heat sources.« less

  4. High Throughput Petrochronology and Sedimentary Provenance Analysis by Automated Phase Mapping and LAICPMS

    NASA Astrophysics Data System (ADS)

    Vermeesch, Pieter; Rittner, Martin; Petrou, Ethan; Omma, Jenny; Mattinson, Chris; Garzanti, Eduardo

    2017-11-01

    The first step in most geochronological studies is to extract dateable minerals from the host rock, which is time consuming, removes textural context, and increases the chance for sample cross contamination. We here present a new method to rapidly perform in situ analyses by coupling a fast scanning electron microscope (SEM) with Energy Dispersive X-ray Spectrometer (EDS) to a Laser Ablation Inductively Coupled Plasma Mass Spectrometer (LAICPMS) instrument. Given a polished hand specimen, a petrographic thin section, or a grain mount, Automated Phase Mapping (APM) by SEM/EDS produces chemical and mineralogical maps from which the X-Y coordinates of the datable minerals are extracted. These coordinates are subsequently passed on to the laser ablation system for isotopic analysis. We apply the APM + LAICPMS method to three igneous, metamorphic, and sedimentary case studies. In the first case study, a polished slab of granite from Guernsey was scanned for zircon, producing a 609 ± 8 Ma weighted mean age. The second case study investigates a paragneiss from an ultra high pressure terrane in the north Qaidam terrane (Qinghai, China). One hundred seven small (25 µm) metamorphic zircons were analyzed by LAICPMS to confirm a 419 ± 4 Ma age of peak metamorphism. The third and final case study uses APM + LAICPMS to generate a large provenance data set and trace the provenance of 25 modern sediments from Angola, documenting longshore drift of Orange River sediments over a distance of 1,500 km. These examples demonstrate that APM + LAICPMS is an efficient and cost effective way to improve the quantity and quality of geochronological data.

  5. Characterization of the Basalt of Broken Tank, NM for the 'in situ' Calibration Target for the Alpha-Particle X-ray Spectrometer (APXS) on the Upcoming Mars Science Laboratory (MSL) Rover

    NASA Astrophysics Data System (ADS)

    Burkemper, L.; King, P. L.; Gellert, R.; Spilde, M. N.; Chamberlin, R. M.

    2008-12-01

    The MSL rover mission will launch in Fall 2009. It is equipped with an APXS for analyzing the bulk chemistry of rocks and soils. To monitor the APXS performance in situ on the martian surface over the extended mission, a calibration target will be included on the MSL rover. Engineering constraints led to a 4.2 cm diameter, 3 mm thick, homogeneous rock disc that would survive vibrations during launch. The basalt from Broken Tank, NM was chosen for the flight disc from ~200 volcanic rocks. The basalt is relatively homogeneous, fine- and even-grained, vesicle-free, and extremely dense and hard due to its ophitic texture. Other volcanic rocks - even well characterized samples of BCR - were ruled out due to vesicles, or high contents of glass, phenocrysts, secondary minerals, or fractures. The flight disc was prepared by hand- polishing to a 0.05 micron finish. We obtained scanning electron microscope back-scattered electron maps and X-ray maps (Al, Mg, Ca, Fe, Ti, Na, and K) on the polished, uncoated surface of the target. One pit (~0.03 mm2) and three tiny surface imperfections (<0.04 mm2) were observed on the surface. Electron microprobe analyses on two C-coated thin sections give the following compositions: olivine cores Fa23Fo77 and rims Fa40Fo60; plagioclase cores Ab42An56Or2 and discrete rims Ab62An7Or31; oxides Ilm67Hm33 and also trace chromite, apatite, chlorite, clays and devitrified glass. The NIH software Scion Image was used to determine the modal abundance of each phase in the basalt disk and in two thin sections. Bulk composition was established with multiple XRF laboratory analyses. There is no significant heterogeneity on the scale of the APXS analysis (~1.5 cm). Sulfides were not observed and XRF verified low Ni (<90 ppm) and S (70 ppm), making these elements ideal to monitor any Martian dust build-up during the surface operation. The rock slab is glued into a Ni frame, mounted vertically and accessible with a brush tool. The K- and L- X-ray lines of Ni can be used to monitor the energy efficiency of the X-ray detector. This work was supported by the Space Science Enhancement Program of the Canadian Space Agency and the New Mexico Space Grant Consortium.

  6. Surface modifications of crystal-ion-sliced LiNbO3 thin films by low energy ion irradiations

    NASA Astrophysics Data System (ADS)

    Bai, Xiaoyuan; Shuai, Yao; Gong, Chaoguan; Wu, Chuangui; Luo, Wenbo; Böttger, Roman; Zhou, Shengqiang; Zhang, Wanli

    2018-03-01

    Single crystalline 128°Y-cut LiNbO3 thin films with a thickness of 670 nm are fabricated onto Si substrates by means of crystal ion slicing (CIS) technique, adhesive wafer bonding using BCB as the medium layer to alleviate the large thermal coefficient mismatch between LiNbO3 and Si, and the X-ray diffraction pattern indicates the exfoliated thin films have good crystalline quality. The LiNbO3 thin films are modified by low energy Ar+ irradiation, and the surface roughness of the films is decreased from 8.7 nm to 3.4 nm. The sputtering of the Ar+ irradiation is studied by scanning electron microscope, atomic force microscope and X-ray photoelectron spectroscopy, and the results show that an amorphous layer exists at the surface of the exfoliated film, which can be quickly removed by Ar+ irradiation. A two-stage etching mechanism by Ar+ irradiation is demonstrated, which not only establishes a new non-contact surface polishing method for the CIS-fabricated single crystalline thin films, but also is potentially useful to remove the residue damage layer produced during the CIS process.

  7. Contour of lingual surface in lower complete denture formed by polished surface impression.

    PubMed

    Heo, Yu-Ri; Kim, Hee-Jung; Son, Mee-Kyoung; Chung, Chae-Heon

    2016-12-01

    The aim of this study was to analyze the shapes of lingual polished surfaces in lower complete dentures formed by polished surface impressions and to provide reference data for use when manufacturing edentulous trays and lower complete dentures. Twenty-six patients with mandibular edentulism were studied. After lower wax dentures were fabricated, wax was removed from the lingual side of the wax denture and a lingual polished surface impression was obtained with tissue conditioner. The definitive denture was scanned with a three-dimensional scanner, and scanned images were obtained. At the cross-sections of the lingual frenum, lateral incisors, first premolars, first molars, and anterior border of the retromolar pads, three points were marked and eight measurements were taken. The Kruskal-Wallis test and a post hoc analysis with the Mann-Whitney test were performed. Each patient showed similar values for the same areas on the left and right sides without a statistically significant difference. The height of the contour of the lingual polished surface at the lingual frenum was halfway between the occlusal plane and lingual border, it moved gradually in a downward direction. The angle from the occlusal plane to the height of the contour of the lingual polished surface was increased as it progressed from the lingual frenum towards the retromolar pads. The shape of the mandibular lingual polished surface was convex at the lingual frenum, lateral incisors and gradually flattened towards the first molars and retromolar pads.

  8. Analysis of Ag(I) Biocide in Water Samples Using Anodic Stripping Voltammetry with a Boron-Doped Diamond Disk Electrode.

    PubMed

    Maldonado, Vanessa Y; Espinoza-Montero, Patricio J; Rusinek, Cory A; Swain, Greg M

    2018-06-05

    The electroanalytical performance of a new commercial boron-doped diamond disk and a traditional nanocrystalline thin-film electrode were compared for the anodic stripping voltammetric determination of Ag(I). The diamond disk electrode is more flexible than the planar film as the former is compatible with most electrochemical cell designs including those incorporating magnetic stirring. Additionally, mechanical polishing and surface cleaning are simpler to execute. Differential pulse anodic stripping voltammetry (DPASV) was used to detect Ag(I) in standard solutions after optimization of the deposition potential, deposition time and scan rate. The optimized conditions were used to determine the concentration of Ag(I) in a NASA simulated potable water sample and a NIST standard reference solution. The electrochemical results were validated by ICP-OES measurements of the same solutions. The detection figures of merit for the disk electrode were as good or superior to those for the thin-film electrode. Detection limits were ≤5 μg L -1 (S/N = 3) for a 120 s deposition period, and response variabilities were <5% RSD. The polished disk electrode presented a more limited linear dynamic range presumably because of the reduced surface area available for metal phase formation. The concentrations of Ag(I) in the two water samples, as determined by DPASV, were in good agreement with the concentrations determined by ICP-OES.

  9. Ion-beam assisted laser fabrication of sensing plasmonic nanostructures

    PubMed Central

    Kuchmizhak, Aleksandr; Gurbatov, Stanislav; Vitrik, Oleg; Kulchin, Yuri; Milichko, Valentin; Makarov, Sergey; Kudryashov, Sergey

    2016-01-01

    Simple high-performance, two-stage hybrid technique was developed for fabrication of different plasmonic nanostructures, including nanorods, nanorings, as well as more complex structures on glass substrates. In this technique, a thin noble-metal film on a dielectric substrate is irradiated by a single tightly focused nanosecond laser pulse and then the modified region is slowly polished by an accelerated argon ion (Ar+) beam. As a result, each nanosecond laser pulse locally modifies the initial metal film through initiation of fast melting and subsequent hydrodynamic processes, while the following Ar+-ion polishing removes the rest of the film, revealing the hidden topography features and fabricating separate plasmonic structures on the glass substrate. We demonstrate that the shape and lateral size of the resulting functional plasmonic nanostructures depend on the laser pulse energy and metal film thickness, while subsequent Ar+-ion polishing enables to vary height of the resulting nanostructures. Plasmonic properties of the fabricated nanostructures were characterized by dark-field micro-spectroscopy, Raman and photoluminescence measurements performed on single nanofeatures, as well as by supporting numerical calculations of the related electromagnetic near-fields and Purcell factors. The developed simple two-stage technique represents a new step towards direct large-scale laser-induced fabrication of highly ordered arrays of complex plasmonic nanostructures. PMID:26776569

  10. Manufacturing of super-polished large aspheric/freeform optics

    NASA Astrophysics Data System (ADS)

    Kim, Dae Wook; Oh, Chang-jin; Lowman, Andrew; Smith, Greg A.; Aftab, Maham; Burge, James H.

    2016-07-01

    Several next generation astronomical telescopes or large optical systems utilize aspheric/freeform optics for creating a segmented optical system. Multiple mirrors can be combined to form a larger optical surface or used as a single surface to avoid obscurations. In this paper, we demonstrate a specific case of the Daniel K. Inouye Solar Telescope (DKIST). This optic is a 4.2 m in diameter off-axis primary mirror using ZERODUR thin substrate, and has been successfully completed in the Optical Engineering and Fabrication Facility (OEFF) at the University of Arizona, in 2016. As the telescope looks at the brightest object in the sky, our own Sun, the primary mirror surface quality meets extreme specifications covering a wide range of spatial frequency errors. In manufacturing the DKIST mirror, metrology systems have been studied, developed and applied to measure low-to-mid-to-high spatial frequency surface shape information in the 4.2 m super-polished optical surface. In this paper, measurements from these systems are converted to Power Spectral Density (PSD) plots and combined in the spatial frequency domain. Results cover 5 orders of magnitude in spatial frequencies and meet or exceed specifications for this large aspheric mirror. Precision manufacturing of the super-polished DKIST mirror enables a new level of solar science.

  11. The analysis of inland water transport on technically developed Polish section of the E70 waterway using GIS tools in the years 2005-2014

    NASA Astrophysics Data System (ADS)

    Rabant, Hubert; Szatten, Dawid; Nadolny, Grzegorz

    2017-11-01

    The article presents the characteristics of changes in the spatial extent of transport on the hydrotechnically developed section of the E70 waterway in Poland using methods and tools of geographic information systems (GIS). The results of the analyzes show the conditions for vessel traffic, their type and volatility in the years 2005-2014. The methods made it possible to analyze the spatial determinants of navigation. The obtained results were referred to the current state and prospects for development of Polish waterways and indicated that the applied tools have a great application role in the research on their logistics and development.

  12. Depth-Profiling Electronic and Structural Properties of Cu(In,Ga)(S,Se)2 Thin-Film Solar Cell.

    PubMed

    Chiang, Ching-Yu; Hsiao, Sheng-Wei; Wu, Pin-Jiun; Yang, Chu-Shou; Chen, Chia-Hao; Chou, Wu-Ching

    2016-09-14

    Utilizing a scanning photoelectron microscope (SPEM) and grazing-incidence X-ray powder diffraction (GIXRD), we studied the electronic band structure and the crystalline properties of the pentanary Cu(In,Ga)(S,Se)2 (CIGSSe) thin-film solar cell as a function of sample depth on measuring the thickness-gradient sample. A novel approach is proposed for studying the depth-dependent information on thin films, which can provide a gradient thickness and a wide cross-section of the sample by polishing process. The results exhibit that the CIGSSe absorber layer possesses four distinct stoichiometries. The growth mechanism of this distinctive compositional distribution formed by a two-stage process is described according to the thermodynamic reaction and the manufacturing process. On the basis of the depth-profiling results, the gradient profiles of the conduction and valence bands were constructed to elucidate the performance of the electrical properties (in this case, Voc = 620 mV, Jsc = 34.6 mA/cm(2), and η = 14.04%); the valence-band maxima (VBM) measured with a SPEM in the spectroscopic mode coincide with this band-structure model, except for a lowering of the VBM observed in the surface region of the absorber layer due to the ordered defect compound (ODC). In addition, the depth-dependent texturing X-ray diffraction pattern presents the crystalline quality and the residual stress for each depth of a thin-film device. We find that the randomly oriented grains in the bottom region of the absorber layer and the different residual stress between the underlying Mo and the absorber interface, which can deteriorate the electrical performance due to peeling-off effect. An anion interstitial defect can be observed on comparing the anion concentration of the elemental distribution with crystalline composition; a few excess sulfur atoms insert in interstitial sites at the front side of the absorber layer, whereas the interstitial selenium atoms insert at the back side.

  13. WFXT Technology Overview

    NASA Astrophysics Data System (ADS)

    Pareschi, G.; Campana, S.

    The Wide Field X-ray Telescope (WFXT) is a medium class mission for X-ray surveys of the sky with an unprecedented area and sensitivity. In order to meet the effective area requirement, the design of the optical system is based on very thin mirror shells, with thicknesses in the 1-2 mm range. In order to get the desired angular resolution (10 arcsec requirement, 5 arcsec goal) across the entire 1× 1 degree FOV (Field Of View), the design of the optical system is based on nested modified grazing incidence Wolter-I mirrors realized with polynomial profiles, focal plane curvature and plate scale corrections. This design guarantees an increased angular resolution at large off-axis angle with respect to the normally used Wolter I configuration, making WFXT ideal for survey purposes. The WFXT X-ray Telescope Assembly is composed by three identical mirror modules of 78 nested shells each, with diameter up to 1.1 m. The epoxy replication process with SiC shells has already been proved to be a valuable technology to meet the angular resolution requirement of 10 arcsec. To further mature the telescope manufacturing technology and to achieve the goal of 5 arcsec, we are considering different materials for the mirror shells with particular care to quartz glass (fused silica), a well-known material with good thermo-mechanical and polishability characteristics that could meet our goal in terms of mass and stiffness, with significant cost and time saving with respect to SiC. To bring the mirror shells to the needed accuracy a deterministic direct polishing method for the mirror shells is under investigation. A direct polishing method has already been used for past missions (as Einstein, Rosat, Chandra): the technological challenge now is to apply it for almost ten times thinner shells. Our approach is based on two main steps: first quartz glass tubes available on the market are grinded to conical profiles, and second the obtained shells are polished to the required polynomial profiles by Computer Numerical Control (CNC) polishing machine.

  14. Metallographic Preparation of Space Shuttle Reaction Control System Thruster Electron Beam Welds for Electron Backscatter Diffraction

    NASA Technical Reports Server (NTRS)

    Martinez, James

    2011-01-01

    A Space Shuttle Reaction Control System (RCS) thruster failed during a firing test at the NASA White Sands Test Facility (WSTF), Las Cruces, New Mexico. The firing test was being conducted to investigate a previous electrical malfunction. A number of cracks were found associated with the fuel closure plate/injector assembly (Fig 1). The firing test failure generated a flight constraint to the launch of STS-133. A team comprised of several NASA centers and other research institutes was assembled to investigate and determine the root cause of the failure. The JSC Materials Evaluation Laboratory was asked to compare and characterize the outboard circumferential electron beam (EB) weld between the fuel closure plate (Titanium 6Al-4V) and the injector (Niobium C-103 alloy) of four different RCS thrusters, including the failed RCS thruster. Several metallographic challenges in grinding/polishing, and particularly in etching were encountered because of the differences in hardness, ductility, and chemical resistance between the two alloys and the bimetallic weld. Segments from each thruster were sectioned from the outboard weld. The segments were hot-compression mounted using a conductive, carbon-filled epoxy. A grinding/polishing procedure for titanium alloys was used [1]. This procedure worked well on the titanium; but a thin, disturbed layer was visible on the niobium surface by means of polarized light. Once polished, each sample was micrographed using bright field, differential interference contrast optical microscopy, and scanning electron microscopy (SEM) using a backscatter electron (BSE) detector. No typical weld anomalies were observed in any of the cross sections. However, areas of large atomic contrast were clearly visible in the weld nugget, particularly along fusion line interfaces between the titanium and the niobium. This prompted the need to better understand the chemistry and microstructure of the weld (Fig 2). Energy Dispersive X-Ray Spectroscopy (EDS) was used to confirm the chemical composition of the variations in contrast in these areas. Niobium alloys generally require exposure to more aggressive chemical reagents than titanium alloys for etching because of niobium s chemical resistance; therefore, the titanium portion of the sample was etched first. A five second immersion in Kroll s reagent revealed a general microstructure on the titanium portion of the sample; however, the titanium heat affected zone closest to the weld, was over-etched due to higher concentrations of refined grains and an increase in eta-phase. The Kroll s etchant also revealed some microstructure in the weld nugget itself; the niobium portion of the sample remained unetched.

  15. High Tc bolometer developments for planetary missions

    NASA Technical Reports Server (NTRS)

    Brasunas, J.; Lakew, B.

    1991-01-01

    A simple polishing technique was developed for thinning the LaAlO3 substrates for high-quality Tc bolometer films, and thus reducing their heat capacity. A 150-ms bolometer was made on a LaAlO3 substrate with a 5-Hz D* value of 1.5 x 10 exp 8. It is shown that passive temperature stabilization is adequate for operation at the transition. There remained excess noise at the transition, but this noise appears to be of nonbolometric origin.

  16. Permian-Triassic boundary microbialites at Zuodeng Section, Guangxi Province, South China: Geobiology and palaeoceanographic implications

    NASA Astrophysics Data System (ADS)

    Fang, Yuheng; Chen, Zhong-Qiang; Kershaw, Stephen; Yang, Hao; Luo, Mao

    2017-05-01

    A previously unknown microbialite bed in the Permian-Triassic (P-Tr) boundary beds of Zuodeng section, Tiandong County, Guangxi, South China comprises a thin (5 cm maximum thickness) stromatolite in the lower part and the remaining 6 m is thrombolite. The Zuodeng microbialite has a pronounced irregular contact between the latest Permian bioclastic limestone and microbialite, as in other sites in the region. The stromatolite comprises low-relief columnar and broad domal geometries, containing faint laminations. The thrombolite displays an irregular mixture of sparitic dark coloured altered microbial fabric and light coloured interstitial sediment in polished blocks. Abundant microproblematic calcimicrobe structures identified here as Gakhumella are preserved in dark coloured laminated areas of the stromatolite and sparitic areas in thrombolites (i.e. the calcimicrobial part, not the interstitial sediment) and are orientated perpendicular to stromatolitic laminae. Each Gakhumella individual has densely arranged segments, which form a column- to fan-shaped structure. Single segments are arch-shaped and form a thin chamber between segments. Gakhumella individuals in the stromatolite and thrombolite are slightly different from each other, but are readily distinguished from the Gakhumella- and Renalcis-like fossils reported from other P-Tr boundary microbialites in having a smaller size, unbranching columns and densely arranged, arch-shaped segments. Renalcids usually possess a larger body size and branching, lobate outlines. Filament sheath aggregates are also observed in the stromatolite and they are all orientated in one direction. Both Gakhumella and filament sheath aggregates may be photosynthetic algae, which may have played an important role in constructing the Zuodeng microbialites. Other calcimicrobes in the Zuodeng microbialite are spheroids, of which a total of five morphological types are recognized from both stromatolite and thrombolite: (1) sparry calcite spheroid without outer sheaths, (2) a large sparry calcite nucleus coated with a thin sparry calcite sheath, (3) a large nucleus of micrite framboid aggregates rimmed by a thin sparry calcite sheath (bacterial clump-like spheroids), (4) a large nucleus of micrite framboid aggregates coated with a thin micritic sheath, and (5) a small sparry nuclei rimmed by coarse-grained, radiated euhedral rays. The irregular contact beneath the Zuodeng microbialites is interpreted as a subaerial exposure surface due to regional regression in South China. The demise of the Zuodeng microbialites may have been due to rapid rise in sea-level because they grew in relatively shallow marine conditions and are overlain by muddy limestones containing pelagic conodonts. Also siliciclastic content increases above the microbialite, suggesting a possible climate-related increase in weathering as the transgression progressed.

  17. Single shot ultrafast dynamic ellipsometry (UDE) of laser-driven shocks in single crystal explosives

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Whitley, Von H; Mcgrane, Shawn D; Moore, David S

    2009-01-01

    We report on the first experiments to measure states in shocked energetic single crystals with dynamic ellipsometry. We demonstrate that these ellipsometric techniques can produce reasonable Hugoniot values using small amounts of crystalline RDX and PETN. Pressures, particle velocities and shock velocities obtained using shocked ellipsometry are comparable to those found using gas-gun flyer plates and molecular dynamics calculations. The adaptation of the technique from uniform thin films of polymers to thick non-perfect crystalline materials was a significant achievement. Correct sample preparation proved to be a crucial component. Through trial and error, we were able to resolve polishing issues, samplemore » quality problems, birefringence effects and mounting difficulties that were not encountered using thin polymer films.« less

  18. Microscopy and microRaman study of periodically poled domains in deeply thinned lithium niobate wafers

    NASA Astrophysics Data System (ADS)

    Bullen, P. S.; Huang, H.-C.; Yang, H.; Dadap, J. I.; Kymissis, I.; Osgood, R. M.

    2016-07-01

    The domain structure of poled deeply thinned lithium niobate is investigated as a function of sample thickness. Free-standing samples of thickness from 25 to 500 μm are prepared by a multiple-cycle polish and annealing procedure and then periodically poled. Using these samples and employing micro-Raman scattering and scanning electron, atomic force, and optical microscopy together, the domain broadening and poling voltage are found to vary in a regular and significant manner. The poled domains show a reduction in width spreading of 38% as the sample thickness is reduced from 500 to 25 μm. Micro-Raman probe measurements verify the quality and the uniformity of the poled domains and provide insight into their thickness-dependent poling contrast.

  19. Solid-state curved focal plane arrays

    NASA Technical Reports Server (NTRS)

    Jones, Todd (Inventor); Nikzad, Shouleh (Inventor); Hoenk, Michael (Inventor)

    2010-01-01

    The present invention relates to curved focal plane arrays. More specifically, the present invention relates to a system and method for making solid-state curved focal plane arrays from standard and high-purity devices that may be matched to a given optical system. There are two ways to make a curved focal plane arrays starting with the fully fabricated device. One way, is to thin the device and conform it to a curvature. A second way, is to back-illuminate a thick device without making a thinned membrane. The thick device is a special class of devices; for example devices fabricated with high purity silicon. One surface of the device (the non VLSI fabricated surface, also referred to as the back surface) can be polished to form a curved surface.

  20. Growth of pure ZnO thin films prepared by chemical spray pyrolysis on silicon

    NASA Astrophysics Data System (ADS)

    Ayouchi, R.; Martin, F.; Leinen, D.; Ramos-Barrado, J. R.

    2003-01-01

    Structural, morphological, optical and electrical properties of ZnO thin films prepared by chemical spray pyrolysis from zinc acetate (Zn(CH 3COO) 2 2H 2O) aqueous solutions, on polished Si(1 0 0), and fused silica substrates for optical characterization, have been studied in terms of deposition time and substrate temperature. The growth of the films present three regimes depending on the substrate temperature, with increasing, constant and decreasing growth rates at lower, middle, and higher-temperature ranges, respectively. Growth rate higher than 15 nm min -1 can be achieved at Ts=543 K. ZnO film morphological and electrical properties have been related to these growth regimes. The films have been characterized by X-ray diffraction, scanning electron microscopy and X-ray photoelectron spectroscopy.

  1. Planarized thick copper gate polycrystalline silicon thin film transistors for ultra-large AMOLED displays

    NASA Astrophysics Data System (ADS)

    Yun, Seung Jae; Lee, Yong Woo; Son, Se Wan; Byun, Chang Woo; Reddy, A. Mallikarjuna; Joo, Seung Ki

    2012-08-01

    A planarized thick copper (Cu) gate low temperature polycrystalline silicon (LTPS) thin film transistors (TFTs) is fabricated for ultra-large active-matrix organic light-emitting diode (AMOLED) displays. We introduce a damascene and chemical mechanical polishing process to embed a planarized Cu gate of 500 nm thickness into a trench and Si3N4/SiO2 multilayer gate insulator, to prevent the Cu gate from diffusing into the silicon (Si) layer at 550°C, and metal-induced lateral crystallization (MILC) technology to crystallize the amorphous Si layer. A poly-Si TFT with planarized thick Cu gate exhibits a field effect mobility of 5 cm2/Vs and a threshold voltage of -9 V, and a subthreshold swing (S) of 1.4 V/dec.

  2. Thin-film magnetless Faraday rotators for compact heterogeneous integrated optical isolators

    NASA Astrophysics Data System (ADS)

    Karki, Dolendra; Stenger, Vincent; Pollick, Andrea; Levy, Miguel

    2017-06-01

    This report describes the fabrication, characterization, and transfer of ultra-compact thin-film magnetless Faraday rotators to silicon photonic substrates. Thin films of magnetization latching bismuth-substituted rare-earth iron garnets were produced from commercially available materials by mechanical lapping, dice polishing, and crystal-ion-slicing. Eleven- μ m -thick films were shown to retain the 45 ° Faraday rotation of the bulk material to within 2 ° at 1.55 μ m wavelength without re-poling. Anti-reflection coated films evince 0.09 dB insertion loses and better than -20 dB extinction ratios. Lower extinction ratios than the bulk are ascribed to multimode propagation. Significantly larger extinction ratios are predicted for single-mode waveguides. Faraday rotation, extinction ratios, and insertion loss tests on He-ion implanted slab waveguides of the same material yielded similar results. The work culminated with bond alignment and transfer of 7 μ m -thick crystal-ion-sliced 50 × 480 μ m 2 films onto silicon photonic substrates.

  3. RF critical field measurement of MgB2 thin films coated on Nb

    NASA Astrophysics Data System (ADS)

    Tajima, T.; Eremeev, G.; Zou, G.; Dolgashev, V.; Martin, D.; Nantista, C.; Tantawi, S.; Yoneda, C.; Moeckly, B. H.; Campisi, I.

    2010-06-01

    Niobium (Nb) Superconducting RF (SRF) cavities have been used or will be used for a number of particle accelerators. The fundamental limit of the accelerating gradient has been thought to be around 50 MV/m due to its RF critical magnetic field of around 200 mT. This limit will prevent new projects requiring higher gradient and compact accelerators from considering SRF structures. There is a theory, however, that promises to overcome this limitation by coating thin (less than the penetration depth) superconductors on Nb. We initiated measurements of critical magnetic fields of Nb coated with various thin film superconductors, starting with MgB2 films deposited using reactive evaporation technique, with the goal to apply this coating to SRF cavities. This paper will present first test results of the RF critical magnetic field of a system consisting of a 10 nm B and a 100 nm MgB2 films deposited on a chemically polished 2-inch single grain Nb substrate.

  4. Seaching for a Silver Lining: Using Pb Isotopes to Constrain the Source of Argentiferous Galena at La Isabela

    NASA Astrophysics Data System (ADS)

    Thibodeau, A. M.; Killick, D. J.; Ruiz, J.; Chesley, J. T.; Baker, M.

    2005-12-01

    This study investigates the smelting and refining of argentiferous galena at La Isabela, Dominican Republic (1493-1498), the town founded by Columbus on his second voyage to the Americas. Archaeologists recovered approximately 100 kilograms of galena and 200 kilograms of metallurgical slag near the remains of a crude furnace unearthed at the site (Deagan and Cruxent 2002). The purpose of this study was to determine if these remains are evidence that members of Columbus's fleet prospected for silver during his second expedition. Samples of ore and slag were examined as metallographic polished sections, and petrographic thin sections by optical and scanning electron microscopes. The composition of the ore and slag allows us to infer these ores were processed in a two-stage procedure to produce silver metal and a lead silicate slag. Electron microprobe analysis of galena indicates highly variable but low Ag content (50 ppm), which may account for the fact some of the ore was left unprocessed. Lead isotope analysis by multi-collector ICP-MS indicates that the galena likely came from a single source and was not mined within the Caribbean. Instead, the isotopic signature of these ores is consistent with an Old World source, possibly in the Linares-La Carolina Pb-Zn vein field of southwestern Spain.

  5. Scatter Measurements Made With Ultraviolet Light

    NASA Astrophysics Data System (ADS)

    Anthon, Erik W.

    1985-09-01

    The quality of optical surfaces is generally evaluated by how much light (normally visible light) is scattered by the surface. Most optical glasses and many coating materials are completely opaque to ultraviolet light (253.7 nm). Ultraviolet light tends to scatter much more than visible light. Scatter measurements made with ultraviolet light are therefore very sensitive and the scatter from second surfaces and from the interior (bulk) of the optical material is eliminated by the opacity. A novel scattermeter that operates with ultraviolet light has been developed. The construction and operation of this scattermeter will be described. Cleaning soon becomes the limiting factor when measuring the surfaces with very low level of scatter. Sensitivity to repeated cleaning has been investigated. Different surfaces are compared and uniformity of surfaces is measured by mapping a surface area with an x-y stage. Polished glass surfaces generally have much higher scatter than natural glass surfaces (fire polished, drawn or floated surfaces). Very low scatter levels have been found on thin drawn glass.

  6. Ion-assisted coating for large-scale Bimorph deformable mirror

    NASA Astrophysics Data System (ADS)

    Mikami, Takuya; Okamoto, Takayuki; Yoshida, Kunio; Jitsuno, Takahisa; Motokoshi, Shinji; Samarkin, Vadim V.; Kudryashov, Alexis V.; Kawanaka, Junji; Miyanaga, Noriaki

    2016-07-01

    We have fabricated a 410 x 468 mm size deformable mirror with 100 Bimorph piezoceramic actuators for the LFEX laser system at Osaka University. In the case of Bimorph-type deformable mirrors, the mirror surface had to be polished and coated after bonding the piezoceramic actuators to the rear side of the thin mirror substrate. This provides a good surface figure, but the coating temperature for the high-reflection mirror was strictly limited because of the thermal fragility of piezoceramic actuators. The mirror substrate with the actuators was polished, and an ion-assisted multilayer dielectric coating was produced at 60 degrees Celsius with our 80-inch coating chamber. The flatness of the mirror just after coating was 7 μm, and reduced by aging to 3.2 μm when the mirror was assembled. The surface figure of the assembled mirror with 20 piezostack bonded actuators is demonstrated and a laser-induced damage threshold tested with a witness sample is also reported.

  7. Rheological properties of magnetorheological polishing fluid featuring plate-like iron particles

    NASA Astrophysics Data System (ADS)

    Shah, Kruti; Choi, Seung-Bok

    2014-10-01

    In this work, magnetorheological polishing fluid (MRP) rheological properties are experimentally investigated for bi-disperse suspension of plate-like iron particles and non-magnetic abrasive particles dispersed in carrier fluid to see the influence of small-sized non-magnetic particle on the large-size Mr fluid. As a first step, structural and morphology of iron plate-like particles are described in details. The rheological properties are then characterized using magnetorheometer. Particle size and volume fraction of both particles play an important role during the breaking and reforming the structure under application of magnetic field which influence on the rheological properties of MRP fluid. Three different constitutive models, such as the Bingham, Herschel-Bulkley and Casson equations are considered to evaluate their predictive capability of apparent viscosity of proposed MRP fluid. The yield stress increases with increasing magnetic field strength. The results obtained from three models show that the flow index exhibits shear thinning behavior of fluid. A comparative work between the model results and experimental results is also undertaken.

  8. D-Shaped Polarization Maintaining Fiber Sensor for Strain and Temperature Monitoring.

    PubMed

    Qazi, Hummad Habib; Mohammad, Abu Bakar; Ahmad, Harith; Zulkifli, Mohd Zamani

    2016-09-15

    A D-shaped polarization-maintaining fiber (PMF) as fiber optic sensor for the simultaneous monitoring of strain and the surrounding temperature is presented. A mechanical end and edge polishing system with aluminum oxide polishing film is utilized to perform sequential polishing on one side (lengthwise) of the PMF in order to fabricate a D-shaped cross-section. Experimental results show that the proposed sensor has high sensitivity of 46 pm/µε and 130 pm/°C for strain and temperature, respectively, which is significantly higher than other recently reported work (mainly from 2013) related to fiber optic sensors. The easy fabrication method, high sensitivity, and good linearity make this sensing device applicable in various applications such as health monitoring and spatial analysis of engineering structures.

  9. D-Shaped Polarization Maintaining Fiber Sensor for Strain and Temperature Monitoring

    PubMed Central

    Qazi, Hummad Habib; Mohammad, Abu Bakar; Ahmad, Harith; Zulkifli, Mohd Zamani

    2016-01-01

    A D-shaped polarization-maintaining fiber (PMF) as fiber optic sensor for the simultaneous monitoring of strain and the surrounding temperature is presented. A mechanical end and edge polishing system with aluminum oxide polishing film is utilized to perform sequential polishing on one side (lengthwise) of the PMF in order to fabricate a D-shaped cross-section. Experimental results show that the proposed sensor has high sensitivity of 46 pm/µε and 130 pm/°C for strain and temperature, respectively, which is significantly higher than other recently reported work (mainly from 2013) related to fiber optic sensors. The easy fabrication method, high sensitivity, and good linearity make this sensing device applicable in various applications such as health monitoring and spatial analysis of engineering structures. PMID:27649195

  10. Piezoelectric actuated micro-resonators based on the growth of diamond on aluminum nitride thin films.

    PubMed

    Hees, J; Heidrich, N; Pletschen, W; Sah, R E; Wolfer, M; Williams, O A; Lebedev, V; Nebel, C E; Ambacher, O

    2013-01-18

    Unimorph heterostructures based on piezoelectric aluminum nitride (AlN) and diamond thin films are highly desirable for applications in micro- and nanoelectromechanical systems. In this paper, we present a new approach to combine thin conductive boron-doped as well as insulating nanocrystalline diamond (NCD) with sputtered AlN films without the need for any buffer layers between AlN and NCD or polishing steps. The zeta potentials of differently treated nanodiamond (ND) particles in aqueous colloids are adjusted to the zeta potential of AlN in water. Thereby, the nucleation density for the initial growth of diamond on AlN can be varied from very low (10(8) cm(-2)), in the case of hydrogen-treated ND seeding particles, to very high values of 10(11) cm(-2) for oxidized ND particles. Our approach yielding high nucleation densities allows the growth of very thin NCD films on AlN with thicknesses as low as 40 nm for applications such as microelectromechanical beam resonators. Fabricated piezo-actuated micro-resonators exhibit enhanced mechanical properties due to the incorporation of boron-doped NCD films. Highly boron-doped NCD thin films which replace the metal top electrode offer Young's moduli of more than 1000 GPa.

  11. Manipulating mammalian cell morphologies using chemical-mechanical polished integrated circuit chips

    NASA Astrophysics Data System (ADS)

    Moussa, Hassan I.; Logan, Megan; Siow, Geoffrey C.; Phann, Darron L.; Rao, Zheng; Aucoin, Marc G.; Tsui, Ting Y.

    2017-12-01

    Tungsten chemical-mechanical polished integrated circuits were used to study the alignment and immobilization of mammalian (Vero) cells. These devices consist of blanket silicon oxide thin films embedded with micro- and nano-meter scale tungsten metal line structures on the surface. The final surfaces are extremely flat and smooth across the entire substrate, with a roughness in the order of nanometers. Vero cells were deposited on the surface and allowed to adhere. Microscopy examinations revealed that cells have a strong preference to adhere to tungsten over silicon oxide surfaces with up to 99% of cells adhering to the tungsten portion of the surface. Cells self-aligned and elongated into long threads to maximize contact with isolated tungsten lines as thin as 180 nm. The orientation of the Vero cells showed sensitivity to the tungsten line geometric parameters, such as line width and spacing. Up to 93% of cells on 10 μm wide comb structures were aligned within ± 20° of the metal line axis. In contrast, only 22% of cells incubated on 0.18 μm comb patterned tungsten lines were oriented within the same angular interval. This phenomenon is explained using a simple model describing cellular geometry as a function of pattern width and spacing, which showed that cells will rearrange their morphology to maximize their contact to the embedded tungsten. Finally, it was discovered that the materials could be reused after cleaning the surfaces, while maintaining cell alignment capability.

  12. Manipulating mammalian cell morphologies using chemical-mechanical polished integrated circuit chips.

    PubMed

    Moussa, Hassan I; Logan, Megan; Siow, Geoffrey C; Phann, Darron L; Rao, Zheng; Aucoin, Marc G; Tsui, Ting Y

    2017-01-01

    Tungsten chemical-mechanical polished integrated circuits were used to study the alignment and immobilization of mammalian (Vero) cells. These devices consist of blanket silicon oxide thin films embedded with micro- and nano-meter scale tungsten metal line structures on the surface. The final surfaces are extremely flat and smooth across the entire substrate, with a roughness in the order of nanometers. Vero cells were deposited on the surface and allowed to adhere. Microscopy examinations revealed that cells have a strong preference to adhere to tungsten over silicon oxide surfaces with up to 99% of cells adhering to the tungsten portion of the surface. Cells self-aligned and elongated into long threads to maximize contact with isolated tungsten lines as thin as 180 nm. The orientation of the Vero cells showed sensitivity to the tungsten line geometric parameters, such as line width and spacing. Up to 93% of cells on 10 μm wide comb structures were aligned within ± 20° of the metal line axis. In contrast, only ~22% of cells incubated on 0.18 μm comb patterned tungsten lines were oriented within the same angular interval. This phenomenon is explained using a simple model describing cellular geometry as a function of pattern width and spacing, which showed that cells will rearrange their morphology to maximize their contact to the embedded tungsten. Finally, it was discovered that the materials could be reused after cleaning the surfaces, while maintaining cell alignment capability.

  13. Manipulating mammalian cell morphologies using chemical-mechanical polished integrated circuit chips

    PubMed Central

    Moussa, Hassan I.; Logan, Megan; Siow, Geoffrey C.; Phann, Darron L.; Rao, Zheng; Aucoin, Marc G.; Tsui, Ting Y.

    2017-01-01

    Abstract Tungsten chemical-mechanical polished integrated circuits were used to study the alignment and immobilization of mammalian (Vero) cells. These devices consist of blanket silicon oxide thin films embedded with micro- and nano-meter scale tungsten metal line structures on the surface. The final surfaces are extremely flat and smooth across the entire substrate, with a roughness in the order of nanometers. Vero cells were deposited on the surface and allowed to adhere. Microscopy examinations revealed that cells have a strong preference to adhere to tungsten over silicon oxide surfaces with up to 99% of cells adhering to the tungsten portion of the surface. Cells self-aligned and elongated into long threads to maximize contact with isolated tungsten lines as thin as 180 nm. The orientation of the Vero cells showed sensitivity to the tungsten line geometric parameters, such as line width and spacing. Up to 93% of cells on 10 μm wide comb structures were aligned within ± 20° of the metal line axis. In contrast, only ~22% of cells incubated on 0.18 μm comb patterned tungsten lines were oriented within the same angular interval. This phenomenon is explained using a simple model describing cellular geometry as a function of pattern width and spacing, which showed that cells will rearrange their morphology to maximize their contact to the embedded tungsten. Finally, it was discovered that the materials could be reused after cleaning the surfaces, while maintaining cell alignment capability. PMID:29152017

  14. 15 CFR 700.31 - Metalworking machines.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... machines covered by this section include: Bending and forming machines Boring machines Broaching machines... Planers and shapers Polishing, lapping, boring, and finishing machines Punching and shearing machines...

  15. 15 CFR 700.31 - Metalworking machines.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... machines covered by this section include: Bending and forming machines Boring machines Broaching machines... Planers and shapers Polishing, lapping, boring, and finishing machines Punching and shearing machines...

  16. 15 CFR 700.31 - Metalworking machines.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... machines covered by this section include: Bending and forming machines Boring machines Broaching machines... Planers and shapers Polishing, lapping, boring, and finishing machines Punching and shearing machines...

  17. 15 CFR 700.31 - Metalworking machines.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... machines covered by this section include: Bending and forming machines Boring machines Broaching machines... Planers and shapers Polishing, lapping, boring, and finishing machines Punching and shearing machines...

  18. 15 CFR 700.31 - Metalworking machines.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... machines covered by this section include: Bending and forming machines Boring machines Broaching machines... Planers and shapers Polishing, lapping, boring, and finishing machines Punching and shearing machines...

  19. Sensing roughness and polish direction

    NASA Astrophysics Data System (ADS)

    Jakobsen, M. L.; Olesen, A. S.; Larsen, H. E.; Stubager, J.; Hanson, S. G.; Pedersen, T. F.; Pedersen, H. C.

    2016-04-01

    As a part of the work carried out on a project supported by the Danish council for technology and innovation, we have investigated the option of smoothing standard CNC machined surfaces. In the process of constructing optical prototypes, involving custom-designed optics, the development cost and time consumption can become relatively large numbers in a research budget. Machining the optical surfaces directly is expensive and time consuming. Alternatively, a more standardized and cheaper machining method can be used, but then the object needs to be manually polished. During the polishing process the operator needs information about the RMS-value of the surface roughness and the current direction of the scratches introduces by the polishing process. The RMS-value indicates to the operator how far he is from the final finish, and the scratch orientation is often specified by the customer in order to avoid complications during the casting process. In this work we present a method for measuring the RMS-values of the surface roughness while simultaneously determining the polishing direction. We are mainly interested in the RMS-values in the range from 0 - 100 nm, which corresponds to the finish categories of A1, A2 and A3. Based on simple intensity measurements we estimates the RMS-value of the surface roughness, and by using a sectioned annual photo-detector to collect the scattered light we can determine the direction of polishing and distinguish light scattered from random structures and light scattered from scratches.

  20. Fabrication and structural properties of AlN submicron periodic lateral polar structures and waveguides for UV-C applications

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Alden, D.; Institut für Festkörperphysik, Technische Universität Berlin, Hardenbergstr. 36, 10623 Berlin; Guo, W.

    Periodically poled AlN thin films with submicron domain widths were fabricated for nonlinear applications in the UV-VIS region. A procedure utilizing metalorganic chemical vapor deposition growth of AlN in combination with laser interference lithography was developed for making a nanoscale lateral polarity structure (LPS) with domain size down to 600 nm. The Al-polar and N-polar domains were identified by wet etching the periodic LPS in a potassium hydroxide solution and subsequent scanning electron microscopy (SEM) characterization. Fully coalesced and well-defined vertical interfaces between the adjacent domains were established by cross-sectional SEM. AlN LPSs were mechanically polished and surface roughness with amore » root mean square value of ∼10 nm over a 90 μm × 90 μm area was achieved. 3.8 μm wide and 650 nm thick AlN LPS waveguides were fabricated. The achieved domain sizes, surface roughness, and waveguides are suitable for second harmonic generation in the UVC spectrum.« less

  1. UV and IR laser radiation's interaction with metal film and teflon surfaces

    NASA Astrophysics Data System (ADS)

    Fedenev, A. V.; Alekseev, S. B.; Goncharenko, I. M.; Koval', N. N.; Lipatov, E. I.; Orlovskii, V. M.; Shulepov, M. A.; Tarasenko, V. F.

    2003-04-01

    The interaction of Xe ([lambda] [similar] 1.73 [mu]m) and XeCl (0.308 [mu]m) laser radiation with surfaces of metal and TiN-ceramic coatings on glass and steel substrates has been studied. Correlation between parameters of surface erosion versus laser-specific energy was investigated. Monitoring of laser-induced erosion on smooth polished surfaces was performed using optical microscopy. The correlation has been revealed between characteristic zones of thin coatings damaged by irradiation and energy distribution over the laser beam cross section allowing evaluation of defects and adhesion of coatings. The interaction of pulsed periodical CO2 ([lambda] [similar] 10.6 [mu]m), and Xe ([lambda] [similar] 1.73 [mu]m) laser radiation with surfaces of teflon (polytetrafluoroethylene—PTFE) has been studied. Monitoring of erosion track on surfaces was performed through optical microscopy. It has been shown that at pulsed periodical CO2-radiation interaction with teflon the sputtering of polymer with formation of submicron-size particles occurs. Dependencies of particle sizes, form, and sputtering velocity on laser pulse duration and target temperature have been obtained.

  2. Fatigue performance of joints executed in pure titanium structures with several diameters.

    PubMed

    Nuñez-Pantoja, Juliana Maria Costa; Vaz, Luis Geraldo; Nóbilo, Mauro Antônio de Arruda; Mesquita, Marcelo Ferraz

    2011-01-01

    This study evaluated fatigue strength of CP-Ti laser-welded joints. Sixty (20/diameter) CP-Ti casted dumbbell rods with diameters of 1.5, 2.0, and 3.5 mm were sectioned and welded using two joint openings (0.0 (00) and 0.6 mm (06)). Six groups were formed, amounting to a total of 9 (n=10) with inclusion of intact groups. Welding was executed using 360 V/8 ms (1.5 and 2.0 mm) and 380 V/9 ms (3.5 mm). Joints were finished, polished, and submitted to radiographic examination to visually analyze presence of porosity (PP). Specimens were submitted to cyclic tests, and the number of cycles until failure (NC) was recorded. Fractured surfaces were examined by SEM. Kruskal-Wallis and Dunn (α=0.05) tests demonstrated that NC was lower for all diameters with 06, and for 3.5 mm/00. NC and PP were found to have a negative correlation (Spearman Coefficient). For CP-Ti frameworks with thin diameters, laser welding is better when structures are juxtaposed.

  3. Mineralogy, textures, and relative age relationships of massive sulfide ore in the West Shasta district, California ( USA).

    USGS Publications Warehouse

    Howe, S.S.

    1985-01-01

    The Devonian massive sulfide orebodies of the West Shasta district in N California are composed primarily of pyrite, with lesser amounts of other sulfide and gangue minerals. Examination of polished thin sections of more than 100 samples from the Mammoth, Shasta King, Early Bird, Balaklala, Keystone, and Iron Mountain mines suggests that mineralization may be divided into 6 paragenetic stages, the last 5 each separated by an episode of deformation: 1) precipitation of fine-grained, locally colloform and framboidal pyrite and sphalerite; 2) deposition of fine-grained arsenopyrite and coarse-grained pyrite; 3) penetration and local replacement of sulfide minerals of stages 1 and 2 along growth zones and fractures by chalcopyrite, sphalerite, galena, tennantite, pyrrhotite, bornite, and idaite; 4) recrystallization and remobilization of existing minerals; 5) deposition of quartz, white mica, chlorite, and calcite; and 6) formation of bornite, digenite, chalcocite, and covellite during supergene enrichment of several orebodies at the Iron Mountain mine. Mineralogic and textural evidence do not support a second major episode of massive sulfide mineralization during the Permian. -from Author

  4. Analysis of the Material Removal Rate in Magnetic Abrasive Finishing of Thin Film Coated Pyrex Glass

    NASA Astrophysics Data System (ADS)

    Lee, Hee Hwan; Lee, Seoung Hwan

    The material removal rate (MRR) during precision finishing/polishing is a key factor, which dictates the process performance. Moreover, the MRR or wear rate is closely related to the material/part reliability. For nanoscale patterning and/or planarization on nano-order thickness coatings, the prediction and in-process monitoring of the MRR is necessary, because the process is not characterizable due to size effects and material property/process condition variations as a result of the coating/substrate interactions. The purpose of this research was to develop a practical methodology for the prediction and in-process monitoring of MRR during nanoscale finishing of coated surfaces. Using a specially designed magnetic abrasive finishing (MAF) and acoustic emission (AE) monitoring setup, experiments were carried out on indium-zinc-oxide (IZO) coated Pyrex glasses. After a given polishing time interval, AFM indentation was conducted for each workpiece sample to measure the adhesion force variations of the coating layers (IZO), which are directly related to the MRR changes. The force variation and AE monitoring data were compared to the MRR calculated form the surface measurement (Nanoview) results. The experimental results demonstrate strong correlations between AFM indentation and MRR measurement data. In addition, the monitored AE signals show sensitivity of the material structure variations of the coating layer, as the polishing progresses.

  5. Evaluation and adaptation of the Dobrolubov and Romer method of microscopic examination of hardened concrete : interim report : methods and equipment used in preparing and examining fluorescent ultrathin sections.

    DOT National Transportation Integrated Search

    1978-01-01

    This report explains the methods and equipment used to produce fluorescent, impregnated, polished, ultrathin sections of portland cement concrete. These sections are used in the study of the microstructure of concrete and are examined with a microsco...

  6. Research on precision grinding technology of large scale and ultra thin optics

    NASA Astrophysics Data System (ADS)

    Zhou, Lian; Wei, Qiancai; Li, Jie; Chen, Xianhua; Zhang, Qinghua

    2018-03-01

    The flatness and parallelism error of large scale and ultra thin optics have an important influence on the subsequent polishing efficiency and accuracy. In order to realize the high precision grinding of those ductile elements, the low deformation vacuum chuck was designed first, which was used for clamping the optics with high supporting rigidity in the full aperture. Then the optics was planar grinded under vacuum adsorption. After machining, the vacuum system was turned off. The form error of optics was on-machine measured using displacement sensor after elastic restitution. The flatness would be convergenced with high accuracy by compensation machining, whose trajectories were integrated with the measurement result. For purpose of getting high parallelism, the optics was turned over and compensation grinded using the form error of vacuum chuck. Finally, the grinding experiment of large scale and ultra thin fused silica optics with aperture of 430mm×430mm×10mm was performed. The best P-V flatness of optics was below 3 μm, and parallelism was below 3 ″. This machining technique has applied in batch grinding of large scale and ultra thin optics.

  7. The prevalence of burnout syndrome in Polish anaesthesiologists.

    PubMed

    Misiołek, Aleksandra; Gorczyca, Piotr; Misiołek, Hanna; Gierlotka, Zbigniew

    2014-01-01

    Burnout syndrome is a psychological response to chronic work-related stress characterized by low enthusiasm towards the job, high psychological exhaustion, indolence and guilt. Being a medical doctor, both in Poland and in other countries, is one of the most stressful occupations and anaesthesiology is considered one of the most stressful specializations, which justify carrying out of the study on Polish anaesthesiologists. The aim of the study was to determine the prevalence of burnout syndrome in Polish anaesthesiologists Non-randomized cross-sectional study was carried out and data were gathered through a self-administrated questionnaire. The sample consisted of 373 Polish anaesthesiologists, 57.6% were women and 42.4% were men. A 66% response rate was achieved. The Burnout Syndrome was measured by the Spanish Burnout Inventory. The prevalence burnout risk was almost 70%. The percentage of participants who indicated very high levels of burnout was 18%; 5.9% of whom fell into profile 2 considered to be clinical. The instrument applied was reliable with Cronbach's alphas exceeding 0.70. The sample is characterized by high burnout risk with 5.9% of clinical cases. Participation in prevention programs is recommended.

  8. Two planar polishing methods by using FIB technique: Toward ultimate top-down delayering for failure analysis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, D. D., E-mail: dandan.wang@globalfoundries.com; Huang, Y. M.; Tan, P. K.

    2015-12-15

    Presently two major limiting factors are hindering the failure analysis (FA) development during the semiconductor manufacturing process and technology improvement: (1) Impossibility of manual polishing on the edge dies due to the amenability of layer peeling off; (2) Abundant demand of multi-locations FA, especially focusing different levels of layers simultaneously. Aiming at resolving these limitations, here we demonstrate two unique high precision polishing methods by using focused ion beam (FIB) technique. One is the vertical top down chemical etching at the aimed location; the other one is the planar top down slicing. Using the FIB for delayering not only solvesmore » these problems mentioned above, but also offers significant advantages over physical planar polishing methods such as: (1) having a better control of the delayering progress, (2) enabling precisely milling at a region of interest, (3) providing the prevention of over-delayering and (4) possessing capability to capture images at the region of interest simultaneously and cut into the die directly to expose the exact failure without damaging other sections of the specimen.« less

  9. Development of optical sciences in Poland

    NASA Astrophysics Data System (ADS)

    Romaniuk, Ryszard S.

    2013-10-01

    Research and technical communities for optics, photonics and optoelectronics is grouped in this country in several organizations and institutions. These are: Photonics Society of Poland (PSP), Polish Committee of Optoelectronics of SEP, Photonics Section of KEiT PAN, Laser Club at WAT, and Optics Section of PTF. Each of these communities keeps slightly different specificity. PSP publishes a quarterly journal Photonics Letters of Poland, stimulates international cooperation, and organizes conferences during Industrial Fairs on Innovativeness. PKOpto SEP organizes didactic diploma competitions in optoelectronics. KEiT PAN takes patronage over national conferences in laser technology, optical fiber technology and communications, and photonics applications. SO-PTF has recently taken a decision to organize a cyclic event "Polish Optical Conference". The third edition of this conference PKO'2013 was held in Sandomierz on 30.06-04.07.2013. The conference scientific and technical topics include: quantum and nonlinear optics, photon physics, optic and technology of lasers and other sources of coherent radiation, optoelectronics, optical integrated circuits, optical fibers, medical optics, instrumental optics, optical spectroscopy, optical metrology, new optical materials, applications of optics, teaching in optics. This paper reviews chosen works presented during the III Polish Optical Conference (PKO'2013), representing the research efforts at different national institutions.

  10. Direct Polishing of Full-Shell, High-Resolution X-Ray Optics

    NASA Technical Reports Server (NTRS)

    Roche, Jacqueline M.; Gubarev, Mikhail V.; Smith, W. Scott; O'Dell, Stephen L.; Kolodziejczak, Jeffrey J.; Weisskopf, Martin C.; Ramsey, Brian D.; Elsner, Ronald F.

    2014-01-01

    Future x-ray telescopes will likely require lightweight mirrors to attain the large collecting areas needed to accomplish the science objectives. Understanding and demonstrating processes now is critical to achieving sub-arcsecond performance in the future. Consequently, designs not only of the mirrors but of fixtures for supporting them during fabrication, metrology, handling, assembly, and testing must be adequately modeled and verified. To this end, MSFC is using finite-element modeling to study the effects of mounting on thin, full-shell grazing-incidence mirrors, during all processes leading to a flight.

  11. Mounting and Alignment of Full-Shell Replicated X-Ray Optics

    NASA Technical Reports Server (NTRS)

    Gubarev, Mikhail; Arnold, William; Kester, Thomas; Ramsey, Brian; Smithers, Martin

    2007-01-01

    We are developing grazing-incidence x-ray optics for astronomy. The optics are full-cylinder mirror shells fabricated using electroformed-nickel replication off super-polished mandrels. For space-based applications where weight is at a premium, very-thin-walled, light-weight mirrors are required. Such shells have been fabricated at MSFC with greater than 15 arcsec resolution. The challenge, however, is to preserve this resolution during mounting and assembly. We present here a status report on a mounting and alignment system currently under development at Marshall Space Flight Center to meet this challenge.

  12. Ion-beam technology and applications

    NASA Technical Reports Server (NTRS)

    Hudson, W. R.; Robson, R. R.; Sovey, J. S.

    1977-01-01

    Ion propulsion research and development yields a mature technology that is transferable to a wide range of nonpropulsive applications, including terrestrial and space manufacturing. A xenon ion source was used for an investigation into potential ion-beam applications. The results of cathode tests and discharge-chamber experiments are presented. A series of experiments encompassing a wide range of potential applications is discussed. Two types of processes, sputter deposition, and erosion were studied. Some of the potential applications are thin-film Teflon capacitor fabrication, lubrication applications, ion-beam cleaning and polishing, and surface texturing.

  13. Thermal Expansion of Metal Matrix Composites.

    DTIC Science & Technology

    1981-08-01

    mirrors by M, for the right-hand side, the interferometer optical path length difference is OPLD I = B1S 1 - BIM 6 (20) Similarly, OPLD2 2 B M5 - S2M4...resultant optics separation) available and by the amount of heat flow the system can tolerate. Thin horizontal Invar or Zerodur support rods have proved...Aluminized end faces, polished < X/5, are preferable to altern-te mounted mirrors 18 of X/2 to X/5 and coated with a few hundred angstroms of vapor-deposited

  14. Advanced Test Reactor National Scientific User Facility (ATR NSUF) Monthly Report December 2014

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Renae Soelberg

    2014-12-01

    • PNNL has completed sectioning of the U.C. Berkeley hydride fuel rodlet 1 (highest burn-up) and is currently polishing samples in preparation for optical metallography. • A disk was successfully sectioned from rodlet 1 at the location of the internal thermocouple tip as desired. The transition from annular pellet to solid pellet is verified by the eutectic-filled inner cavity located on the back face of this disk (top left) and the solid front face (bottom left). Preliminary low-resolution images indicate interesting sample characteristics in the eutectic surrounding the rodlet at the location of the outer thermocouple tip (right). This samplemore » has been potted and is currently being polished for high-resolution optical microscopy and subsequent SEM analysis. (See images.)« less

  15. Paint Analysis

    NASA Technical Reports Server (NTRS)

    1994-01-01

    Lewis Research Center (LEW) has assisted The Cleveland Museum of Art (CMA) in analyzing the museum's paintings. Because of the many layers of paint that are often involved, this is a complex process. The cross-section of a paint chip must be scanned with a microscope to determine whether a paint layer is original or a restoration. The paint samples, however, are rarely flat enough for high magnification viewing and are frequently scratched. LEW devised an automated method that produces intact, flat, polished paint cross-sections. A sophisticated microprocessor-controlled grinding and polishing machine was manually employed in preparation of exotic samples for aerospace research was a readily adaptable technique. It produced perfectly flat samples with clearly defined layers. The process has been used successfully on a number of paintings, and LEW and CMA are considering additional applications.

  16. New Capabilities in the Analysis of Sub-micrometer Regions in Geological Materials with the Field Emission Electron Microprobe

    NASA Astrophysics Data System (ADS)

    Armstrong, J. T.; McSwiggen, P.; Nielsen, C.

    2013-12-01

    Quantitative electron microprobe analysis has revolutionized two-dimensional elemental analysis of Earth materials at the micrometer-scale. Newly available commercial field emission (FE-) source instruments represent significant technological advances in quantitative measurement with high spatial resolution at sub-micrometer scale - helping to bridge the gap between conventional microprobe and AEM analyses. Their performance specifications suggest the ability to extend routine quantitative analyses from ~3-5 micrometer diameter areas down to 1-2 micrometer diameter at beam energies of 15 keV; and, with care, down to 200-500 nm diameter at reduced beam energies. . In order to determine whether the level of performance suggested by the specifications is realistic, we spent a week doing analyses at the newly installed JEOL JXA-8530F field emission microprobe at Arizona State University, using a series of samples that are currently being studied in various projects at CIW. These samples included: 1) high-pressure experiment run product containing intergrowths of sub-micrometer grains of metal, sulfide, Fe-Mg-perovskite, and ferropericlase; 2) a thin section of the Ivankinsky basalt, part of the Siberian flood basalt sequence containing complex sub-micrometer intergrowths of magnetite, titanomagnetite, ilmenite, titanite and rutile; 3) a polished section of the Giroux pallasite, being studied for element partitioning, that we used as an analogue to test the capabilities for zonation and diffusion determination; and 4) a polished section of the Semarkona ordinary chondrite containing chondules comprised of highly zoned and rimmed olivines and pyroxenes in a complex mesostasis of sub-micrometer pyroxenes and glass. The results of these analyses that we will present confirmed our optimism regarding the new analytical capabilities of a field emission microprobe. We were able, at reduced voltages, to accurately analyze the major and minor element composition of intergrowth and rimming phases as small as 200 nm without artifact contribution from the surrounding phases. We were able to determine the compositional gradients at kamacite-taenite boundaries in the pallasite specimen with a resolution of ~180 nm, enabling much higher precision and accuracy determination of the meteorite's cooling rate than previously possible with microprobe measurements. We were able to determine the composition and zonation of phases in the experimental run product, none of which were large enough to be analyzable in a conventional electron microprobe.

  17. Sociocultural Appearance Standards and Risk Factors for Eating Disorders in Adolescents and Women of Various Ages

    PubMed Central

    Izydorczyk, Bernadetta; Sitnik-Warchulska, Katarzyna

    2018-01-01

    The main aim of the present study was to verify the level of impact of sociocultural appearance standards (passive awareness and active internalization) have on body dissatisfaction, the desire to engage in a relentless pursuit of thinness, the adoption of a perfectionistic attitude toward the body, and the development of a tendency to engage in bulimic eating behavior, which can develop in adolescent girls and women of varying ages. The study group comprised 234 individuals: 95 secondary school girls, 33 high school girls, 56 female students, and 50 employed women, all of whom were living in southern Poland. Participants were not diagnosed with any psychiatric disorders (including eating disorders). The variables were measured using the Polish version of Garner’s Eating Disorder Inventory and the Polish Sociocultural Attitudes Towards Physical Appearance and Body Image Inventory [based on the SATAQ-3 (Sociocultural Attitudes Towards Appearance Questionnaire Scale-3)]. The findings revealed that the youngest Polish girls (aged 12–15) reported the highest level of risk factors for eating disorders. Among the entire study group, the internalization of appearance standards and the pressure associated with various media messages were determined to be predictors of the pursuit of thinness, regardless of age and body mass index values. The second most significant variable explained by the internalization of sociocultural standards was body dissatisfaction. The internalization of sociocultural norms provided a significant explanation of bulimic tendencies only in the youngest girls. Perfectionism proved not to be affected by the sociocultural impact of mass media. The adult women had the lowest average scores over the entire study population regarding exposure frequency to body images in mass media and regarding the experience of pressure exerted by sociocultural norms. The high level of internalization of sociocultural appearance standards seems to be significantly linked to body satisfaction in women aged 30 and older. Young adolescent girls constitute a high-risk group for a specific psychological proneness to developing eating disorders as a result of the sociocultural influence exerted by mass media. The obtained study results can prove helpful in creating education programs in preventive healthcare aimed particularly at the youngest adolescents. PMID:29651268

  18. Characterization of chemical interactions during chemical mechanical polishing (CMP) of copper

    NASA Astrophysics Data System (ADS)

    Lee, Seung-Mahn

    2003-10-01

    Chemical mechanical polishing (CMP) has received much attention as an unique technique to provide a wafer level planarization in semiconductor manufacturing. However, despite the extensive use of CMP, it still remains one of the least understood areas in semiconductor processing. The lack of the fundamental understanding is a significant barrier to further advancements in CMP technology. One critical aspect of metal CMP is the formation of a thin surface layer on the metal surface. The formation and removal of this layer controls all the aspects of the CMP process, including removal rate, surface finish, etc. In this dissertation, we focus on the characterization of the formation and removal of the thin surface layer on the copper surface. The formation dynamics was investigated using static and dynamic electrochemical techniques, including potentiodynamic scans and chronoamperometry. The results were validated using XPS measurements. The mechanical properties of the surface layer were investigated using nanoindentation measurements. The electrochemical investigation showed that the thickness of the surface layer is controlled by the chemicals such as an oxidizer (hydrogen peroxide), a corrosion inhibitor (benzotriazole), a complexing agent (citric acid), and their concentrations. The dynamic electrochemical measurements indicated that the initial layer formation kinetics is unaffected by the corrosion inhibitors. The passivation due to the corrosion inhibitor becomes important only on large time scales (>200 millisecond). The porosity and the density of the chemically modified surface layer can be affected by additives of other chemicals such as citric acid. An optimum density of the surface layer is required for high polishing rate while at the same time maintaining a high degree of surface finish. Nanoindentation measurements indicated that the mechanical properties of the surface layer are strongly dependent on the chemical additives in the slurry. The CMP removal rates were found to be in good agreement with the initial reaction kinetics as well as the mechanical properties of the chemically modified surface layer. In addition, the material removal model based on the micro- and nano-scale interactions, which were measured experimentally, has been developed.

  19. Pressure-Sensor Assembly Technique

    NASA Technical Reports Server (NTRS)

    Pruzan, Daniel A.

    2003-01-01

    Nielsen Engineering & Research (NEAR) recently developed an ultrathin data acquisition system for use in turbomachinery testing at NASA Glenn Research Center. This system integrates a microelectromechanical- systems- (MEMS-) based absolute pressure sensor [0 to 50 psia (0 to 345 kPa)], temperature sensor, signal-conditioning application-specific integrated circuit (ASIC), microprocessor, and digital memory into a package which is roughly 2.8 in. (7.1 cm) long by 0.75 in. (1.9 cm) wide. Each of these components is flip-chip attached to a thin, flexible circuit board and subsequently ground and polished to achieve a total system thickness of 0.006 in. (0.15 mm). Because this instrument is so thin, it can be quickly adhered to any surface of interest where data can be collected without disrupting the flow being investigated. One issue in the development of the ultrathin data acquisition system was how to attach the MEMS pressure sensor to the circuit board in a manner which allowed the sensor s diaphragm to communicate with the ambient fluid while providing enough support for the chip to survive the grinding and polishing operations. The technique, developed by NEAR and Jabil Technology Services Group (San Jose, CA), is described below. In the approach developed, the sensor is attached to the specially designed circuit board, see Figure 1, using a modified flip-chip technique. The circular diaphragm on the left side of the sensor is used to actively measure the ambient pressure, while the diaphragm on the right is used to compensate for changes in output due to temperature variations. The circuit board is fabricated with an access hole through it so that when the completed system is installed onto a wind tunnel model (chip side down), the active diaphragm is exposed to the environment. After the sensor is flip-chip attached to the circuit board, the die is underfilled to support the chip during the subsequent grinding and polishing operations. To prevent this underfill material from getting onto the sensor s diaphragms, the circuit board is fabricated with two 25- micrometer-tall polymer rings, sized so that the diaphragms fit inside the rings once the chip is attached.

  20. Ore microscopy of the Paoli silver-copper deposit, Oklahoma

    USGS Publications Warehouse

    Thomas, C.A.; Hagni, R.D.; Berendsen, P.

    1991-01-01

    The Paoli silver-copper deposit is located in south-central Oklahoma, 56 km south-southeast from Norman, Oklahoma. It was mined for high-grade silver-copper near the beginning of this century, and intensive exploratory drilling during the early 1970's delineated unmined portions of the deposit. A collaborative study between the U.S.G.S., the Kansas Geological Survey, and the University of Missouri-Rolla was undertaken to provide new information on the character of red bed copper deposits of the Midcontinent region. The Paoli deposit has been interpreted to occur as a roll-front type of deposit. The silver and copper mineralization occurs within paleochannels in the Permian Wellington Formation. The silver-copper interfaces appear to be controlled by oxidation-reduction interfaces that are marked by grey to red color changes in the host sandstone. Ore microscopic examinations of polished thin sections show that unoxidized ore consists of chalcocite, digenite, chalcopyrite, covellite and pyrite; and oxidized ores are characterized by covellite, bornite, hematite and goethite. In sandstone-hosted ores, chalcocite and digenite replace dolomite and border clastic quartz grains. In siltstone-hosted ores, the copper sulfide grains have varied shapes; most are irregular in shape and 5-25 ??m across, others have euhedral shapes suggestive of pyrite crystal replacements, and some are crudely spherical and are 120-200 ??m across. Chalcopyrite is the predominant copper sulfide at depth. Covellite and malachite replace chalcocite and digenite near the surface. Silver only occurs as native silver; most as irregularly shaped grains 40-80 ??m across, but some as cruciform crystals that are up to 3.5 mm across. The native silver has been deposited after copper sulfides, and locally replaces chalcocite. Surficial nodules of pyrite, malachite and hematite locally are present in outcrops at the oxidation-reduction fronts. Polished sections of the nodules show that malachite forms a cement around quartz sand grains, and brecciated pyrite grains are surrounded by rims of hematite and goethite. Dolomite is the principal sandstone cement. Cathodoluminescence microscopic study of the mineral has shown that it was deposited during seven periods before the copper sulfide mineralization. ?? 1991.

  1. Ultrafast nonlinear optical properties of thin-solid DNA film and their application as a saturable absorber in femtosecond mode-locked fiber laser

    PubMed Central

    Khazaeinezhad, Reza; Hosseinzadeh Kassani, Sahar; Paulson, Bjorn; Jeong, Hwanseong; Gwak, Jiyoon; Rotermund, Fabian; Yeom, Dong-Il; Oh, Kyunghwan

    2017-01-01

    A new extraordinary application of deoxyribonucleic acid (DNA) thin-solid-film was experimentally explored in the field of ultrafast nonlinear photonics. Optical transmission was investigated in both linear and nonlinear regimes for two types of DNA thin-solid-films made from DNA in aqueous solution and DNA-cetyltrimethylammonium chloride (CTMA) in an organic solvent. Z-scan measurements revealed a high third-order nonlinearity with n2 exceeding 10−9 at a wavelength of 1570 nm, for a nonlinarity about five orders of magnitude larger than that of silica. We also demonstrated ultrafast saturable absorption (SA) with a modulation depth of 0.43%. DNA thin solid films were successfully deposited on a side-polished optical fiber, providing an efficient evanescent wave interaction. We built an organic-inorganic hybrid all-fiber ring laser using DNA film as an ultrafast SA and using Erbium-doped fiber as an efficient optical gain medium. Stable transform-limited femtosecond soliton pulses were generated with full width half maxima of 417 fs for DNA and 323 fs for DNA-CTMA thin-solid-film SAs. The average output power was 4.20 mW for DNA and 5.46 mW for DNA-CTMA. Detailed conditions for DNA solid film preparation, dispersion control in the laser cavity and subsequent characteristics of soliton pulses are discussed, to confirm unique nonlinear optical applications of DNA thin-solid-film. PMID:28128340

  2. Spectroscopic ellipsometry analysis of a thin film composite membrane consisting of polysulfone on a porous α-alumina support.

    PubMed

    Ogieglo, Wojciech; Wormeester, Herbert; Wessling, Matthias; Benes, Nieck E

    2012-02-01

    Exposure of a thin polymer film to a fluid can affect properties of the film such as the density and thickness. In particular in membrane technology, these changes can have important implications for membrane performance. Spectroscopic ellipsometry is a convenient technique for in situ studies of thin films, because of its noninvasive character and very high precision. The applicability of spectroscopic ellipsometry is usually limited to samples with well-defined interfacial regions, whereas in typical composite membranes, often substantial and irregular intrusion of the thin film into the pores of a support exists. In this work, we provide a detailed characterization of a polished porous alumina membrane support, using variable-angle spectroscopic ellipsometry in combination with atomic force microscopy and mercury porosimetry. Two Spectroscopic ellipsometry optical models are presented that can adequately describe the surface roughness of the support. These models consider the surface roughness as a distinct layer in which the porosity gradually increases toward the outer ambient interface. The first model considers the porosity profile to be linear; the second model assumes an exponential profile. It is shown that the models can be extended to account for a composite membrane geometry, by deposition of a thin polysulfone film onto the support. The developed method facilitates practicability for in situ spectroscopic ellipsometry studies of nonequilibrium systems, i.e., membranes under actual permeation conditions.

  3. Artifacts in slab average-intensity-projection images reformatted from JPEG 2000 compressed thin-section abdominal CT data sets.

    PubMed

    Kim, Bohyoung; Lee, Kyoung Ho; Kim, Kil Joong; Mantiuk, Rafal; Kim, Hye-ri; Kim, Young Hoon

    2008-06-01

    The objective of our study was to assess the effects of compressing source thin-section abdominal CT images on final transverse average-intensity-projection (AIP) images. At reversible, 4:1, 6:1, 8:1, 10:1, and 15:1 Joint Photographic Experts Group (JPEG) 2000 compressions, we compared the artifacts in 20 matching compressed thin sections (0.67 mm), compressed thick sections (5 mm), and AIP images (5 mm) reformatted from the compressed thin sections. The artifacts were quantitatively measured with peak signal-to-noise ratio (PSNR) and a perceptual quality metric (High Dynamic Range Visual Difference Predictor [HDR-VDP]). By comparing the compressed and original images, three radiologists independently graded the artifacts as 0 (none, indistinguishable), 1 (barely perceptible), 2 (subtle), or 3 (significant). Friedman tests and exact tests for paired proportions were used. At irreversible compressions, the artifacts tended to increase in the order of AIP, thick-section, and thin-section images in terms of PSNR (p < 0.0001), HDR-VDP (p < 0.0001), and the readers' grading (p < 0.01 at 6:1 or higher compressions). At 6:1 and 8:1, distinguishable pairs (grades 1-3) tended to increase in the order of AIP, thick-section, and thin-section images. Visually lossless threshold for the compression varied between images but decreased in the order of AIP, thick-section, and thin-section images (p < 0.0001). Compression artifacts in thin sections are significantly attenuated in AIP images. On the premise that thin sections are typically reviewed using an AIP technique, it is justifiable to compress them to a compression level currently accepted for thick sections.

  4. Method for fabricating an ultra-low expansion mask blank having a crystalline silicon layer

    DOEpatents

    Cardinale, Gregory F.

    2002-01-01

    A method for fabricating masks for extreme ultraviolet lithography (EUVL) using Ultra-Low Expansion (ULE) substrates and crystalline silicon. ULE substrates are required for the necessary thermal management in EUVL mask blanks, and defect detection and classification have been obtained using crystalline silicon substrate materials. Thus, this method provides the advantages for both the ULE substrate and the crystalline silicon in an Extreme Ultra-Violet (EUV) mask blank. The method is carried out by bonding a crystalline silicon wafer or member to a ULE wafer or substrate and thinning the silicon to produce a 5-10 .mu.m thick crystalline silicon layer on the surface of the ULE substrate. The thinning of the crystalline silicon may be carried out, for example, by chemical mechanical polishing and if necessary or desired, oxidizing the silicon followed by etching to the desired thickness of the silicon.

  5. Solar cells with gallium phosphide/silicon heterojunction

    NASA Astrophysics Data System (ADS)

    Darnon, Maxime; Varache, Renaud; Descazeaux, Médéric; Quinci, Thomas; Martin, Mickaël; Baron, Thierry; Muñoz, Delfina

    2015-09-01

    One of the limitations of current amorphous silicon/crystalline silicon heterojunction solar cells is electrical and optical losses in the front transparent conductive oxide and amorphous silicon layers that limit the short circuit current. We propose to grow a thin (5 to 20 nm) crystalline Gallium Phosphide (GaP) by epitaxy on silicon to form a more transparent and more conducting emitter in place of the front amorphous silicon layers. We show that a transparent conducting oxide (TCO) is still necessary to laterally collect the current with thin GaP emitter. Larger contact resistance of GaP/TCO increases the series resistance compared to amorphous silicon. With the current process, losses in the IR region associated with silicon degradation during the surface preparation preceding GaP deposition counterbalance the gain from the UV region. A first cell efficiency of 9% has been obtained on ˜5×5 cm2 polished samples.

  6. Origin and significance of clay-coated fractures in mudrock fragments of the SAFOD borehole (Parkfield, California)

    USGS Publications Warehouse

    Schleicher, A.M.; van der Pluijm, B.A.; Solum, J.G.; Warr, L.N.

    2006-01-01

    The clay mineralogy and texture of rock fragments from the SAFOD borehole at 3067 m and 3436 m measured depth (MD) was investigated by electron microscopy (SEM, TEM) and X-ray-diffraction (XRD). The washed and ultrasonically cleaned samples show slickenfiber striations and thin films of Ca-K bearing smectite that are formed on polished fault surfaces, along freshly opened fractures and within adjacent mineralized veins. The cation composition and hydration behavior of these films differ from the Namontmorillonite of the fresh bentonite drilling mud, although there is more similarity with circulated mud recovered from 3479 m MD. We propose that these thin film smectite precipitates formed by natural nucleation and crystal growth during fault creep, probably associated with the shallow circulation of low temperature aqueous fluids along this shallow portion of the San Andreas Fault. Copyright 2006 by the American Geophysical Union.

  7. The effect of mechanical load cycling and polishing time on microleakage of class V glass-ionomer and composite restorations: A scanning electron microscopy evaluation

    PubMed Central

    Mirzaie, Mansoreh; Yasini, Esmail; Kermanshah, Hamid; Omidi, Baharan Ranjbar

    2014-01-01

    Background: Microleakage is one of the challenging concerns in direct filling restorations. Understanding of its related factors is important in clinical practice. The aim of this study was scanning electron microscopy (SEM) evaluation of marginal integrity in three types of tooth-colored restorative materials in class V cavity preparations and the effect of load cycling and polishing time on the microleakage. Materials and Methods: In this in vitro experimental study, class V cavity preparations were prepared on the buccal and lingual surfaces of 60 bovine incisors. The specimens were divided into three groups each containing 20 teeth: group 1: Filtek Z350, Group 2: Fuji IX/G Coat Plus, Group 3: Fuji II LC/GC varnish. In each group, 2 subgroups (n = 20) were established based on finishing time (immediate or delayed by 24 h). All specimens were thermocycled (×2,000, 5-50°C). In each sub groups, half of the teeth were load cycled. Epoxy resin replicas of 24 specimens were evaluated under field emission-SEM and interfacial gaps were measured. All teeth were then immersed in 0.5% basic fuchsin dye for 24 h, sectioned and observed under stereomicroscope. Data were analyzed with Kruskal-Wallis’ test and Mann-Whitney U test and a comparison between incisal and cervical microleakage was made with Wilcoxon test. P < 0.05 was considered as significant. Results: Load cycling and filling material had a significant effect on microleakage, but polishing time did not. Cervical microleakage in Z350/load cycle/immediate polish and Fuji IX/load cycle/immediate or delayed polish and Fuji IX/no load cycle/immediate polish were significantly higher than incisal microleakage. Conclusion: It was concluded that the cervical sealing ability of Fuji IX under load cycling was better than Fuji II LC. Under load cycling and immediate polishing Z350 showed better marginal integrity than both Fuji II LC and Fuji IX. The immediate polishing didn’t cause a statistically significant increase in microleakage of evaluated tooth-colored class V restorations. PMID:24688568

  8. The effect of mechanical load cycling and polishing time on microleakage of class V glass-ionomer and composite restorations: A scanning electron microscopy evaluation.

    PubMed

    Mirzaie, Mansoreh; Yasini, Esmail; Kermanshah, Hamid; Omidi, Baharan Ranjbar

    2014-01-01

    Microleakage is one of the challenging concerns in direct filling restorations. Understanding of its related factors is important in clinical practice. The aim of this study was scanning electron microscopy (SEM) evaluation of marginal integrity in three types of tooth-colored restorative materials in class V cavity preparations and the effect of load cycling and polishing time on the microleakage. In this in vitro experimental study, class V cavity preparations were prepared on the buccal and lingual surfaces of 60 bovine incisors. The specimens were divided into three groups each containing 20 teeth: group 1: Filtek Z350, Group 2: Fuji IX/G Coat Plus, Group 3: Fuji II LC/GC varnish. In each group, 2 subgroups (n = 20) were established based on finishing time (immediate or delayed by 24 h). All specimens were thermocycled (×2,000, 5-50°C). In each sub groups, half of the teeth were load cycled. Epoxy resin replicas of 24 specimens were evaluated under field emission-SEM and interfacial gaps were measured. All teeth were then immersed in 0.5% basic fuchsin dye for 24 h, sectioned and observed under stereomicroscope. Data were analyzed with Kruskal-Wallis' test and Mann-Whitney U test and a comparison between incisal and cervical microleakage was made with Wilcoxon test. P < 0.05 was considered as significant. Load cycling and filling material had a significant effect on microleakage, but polishing time did not. Cervical microleakage in Z350/load cycle/immediate polish and Fuji IX/load cycle/immediate or delayed polish and Fuji IX/no load cycle/immediate polish were significantly higher than incisal microleakage. It was concluded that the cervical sealing ability of Fuji IX under load cycling was better than Fuji II LC. Under load cycling and immediate polishing Z350 showed better marginal integrity than both Fuji II LC and Fuji IX. The immediate polishing didn't cause a statistically significant increase in microleakage of evaluated tooth-colored class V restorations.

  9. Effects of the LDEF orbital environment on the reflectance of optical mirror materials

    NASA Technical Reports Server (NTRS)

    Herzig, Howard; Fleetwood, Charles, Jr.

    1995-01-01

    Specimens of eight different optical mirror materials were flown in low earth orbit as part of the Long Duration Exposure Facility (LDEF) manifest to determine their ability to withstand exposure to the residual atomic oxygen and other environmental effects at those altitudes. Optical thin films of aluminum, gold, iridium, osmium, platinum, magnesium fluoride-overcoated aluminum and reactively deposited, silicon monoxide-protected aluminum, all of which were vacuum deposited on polished fused silica substrates, were included as part of Experiment S0010, Exposure of Spacecraft Coatings. Two specimens of polished, chemical vapor deposited (CVD) silicon carbide were installed in sites available in Experiment A0114, Interaction of Atomic Oxygen with Solid Surfaces at Orbital Altitudes, which included trays in two of the spacecraft bays, one on the leading edge and the other on the trailing edge. One of the silicon carbide samples was located in each of these trays. This paper will compare specular reflectance data from the preflight and postflight measurements made on each of these samples and attempt to explain the changes in light of the specific environments to which the experiments were exposed.

  10. Improvement of the recombination and infrared light losses by rear surface chemical polishing in silicon heterojunction solar cells

    NASA Astrophysics Data System (ADS)

    Yang, Xueliang; Zhang, Yi; Li, Feng; Sun, Yun

    2017-06-01

    Rear surface chemical polishing (RSCP) was investigated for the improvement of the internal reflection and surface passivation of heterojunction solar cells with intrinsic thin layers (HIT). The HIT solar cells without or with RSCP treatment were prepared by plasma-enhanced chemical vapor deposition and physical vapor deposition techniques. Scanning electron microscopy results showed that rounding of the spires and V-groove bottom of the pyramid as well as smoothing of incline surface of the pyramid were achieved. These effects would decrease the loss of infrared light transmittance and interface recombination at the rear surface of the cells. To experimentally corroborate these two points, two special geometries, ITO/c-Si/hydrogenated amorphous silicon (a-Si:H)/ITO and a-Si:H/c-Si/a-Si:H, were introduced as a test of the reflectance/transmittance spectra and the minority carrier lifetime. Weakened transmittance and enhanced lifetime were observed for the sample with RSCP, which are responsible for the improvement of J sc and V oc, respectively. Therefore, RSCP is a promising candidate for improving the performance of HIT solar cells.

  11. A study on the relationships between corrosion properties and chemistry of thermally oxidised surface films formed on polished commercial magnesium alloys AZ31 and AZ61

    NASA Astrophysics Data System (ADS)

    Feliu, Sebastián; Samaniego, Alejandro; Barranco, Violeta; El-Hadad, A. A.; Llorente, Irene; Serra, Carmen; Galván, J. C.

    2014-03-01

    This paper studies the changes in chemical composition of the thin oxide surface films induced by heating in air at 200 °C for time intervals from 5 min to 60 min on the freshly polished commercial AZ31 and AZ61 alloys with a view to better understanding their protective properties. This thermal treatment resulted in the formation of layers enriched in metallic aluminium at the interface between the outer MgO surface films and the bulk material. A strong link was found between the degree of metallic Al enrichment in the subsurface layer (from 10 to 15 at.%) observed by XPS (X-ray photoelectron spectroscopy) in the AZ61 treated samples and the increase in protective properties observed by EIS (electrochemical impedance spectroscopy) in the immersion test in 0.6 M NaCl. Heating for 5-60 min in air at 200 °C seems to be an effective, easy to perform and inexpensive method for increasing the corrosion resistance of the AZ61 alloy by approximately two or three times.

  12. Biocompatible Nb2O5 thin films prepared by means of the sol-gel process.

    PubMed

    Velten, D; Eisenbarth, E; Schanne, N; Breme, J

    2004-04-01

    Thin biocompatible oxide films with an optimised composition and structure on the surface of titanium and its alloys can improve the implant integration. The preparation of these thin oxide layers with the intended improvement of the surface properties can be realised by means of the sol-gel process. Nb2O5 is a promising coating material for this application because of its extremely high corrosion resistance and thermodynamic stability. In this study, thin Nb2O5 layers ( < 200 nm) were prepared by spin coating of polished discs of cp-titanium with a sol consisting of a mixture of niobium ethoxide, butanol and acetylacetone. The thickness, phase composition, corrosion resistance and the wettability of the oxide layers were determined after an optimisation of the processing parameters for deposition of oxide without any organic impurities. The purity of the oxide layer is an important aspect in order to avoid a negative response to the cell adhesion. The biocompatibility of the oxide layers which was investigated by in vitro tests (morphology, proliferation rate, WST-1, cell spreading) is improved as compared to uncoated and TiO2 sol-gel coated cp-titanium concerning the spreading of cells, collagen I synthesis and wettability.

  13. Effect of high energy ions on the electrical and morphological properties of Poly(3-Hexylthiophene) (P3HT) thin film

    NASA Astrophysics Data System (ADS)

    Sharma, Trupti; Singhal, R.; Vishnoi, R.; Sharma, G. D.; Biswas, S. K.

    2018-05-01

    The spin-coated thin films of Poly(3-Hexylthiophene) (P3HT) on the glass and Si (double side polished) substrates have been irradiated with 55 MeV Si+4 swift heavy ions (SHI) at fluences in the range from 1 × 1010 to 1 × 1012 ions/cm2. Structural modifications produced by energetic ions are observed by characterization of pristine and irradiated P3HT thin films. Different techniques like high-resolution X-ray diffraction (HR-XRD), micro-Raman spectroscopy and Fourier transform infrared spectroscopy (FTIR) were used to analyze the structural changes in the material. A significant increase in crystallinity and room temperature electrical conductivity of P3HT film has been detected on exposure to the heavy ions. The observed increase in the electrical conductivity with increased fluences is explained in the light of improved ordering of polymer chains after irradiation. Mott's variable range hopping model has been used to explain the conduction mechanism in the material in the temperature range of 230-350 K. The modification in surface properties also observed using AFM analysis and contact angle measurement. It is observed that nature of the P3HT thin films remains hydrophobic after irradiation.

  14. Co thickness dependence of structural and magnetic properties in spin quantum cross devices utilizing stray magnetic fields

    NASA Astrophysics Data System (ADS)

    Kaiju, H.; Kasa, H.; Komine, T.; Mori, S.; Misawa, T.; Abe, T.; Nishii, J.

    2015-05-01

    We investigate the Co thickness dependence of the structural and magnetic properties of Co thin-film electrodes sandwiched between borate glasses in spin quantum cross (SQC) devices that utilize stray magnetic fields. We also calculate the Co thickness dependence of the stray field between the two edges of Co thin-film electrodes in SQC devices using micromagnetic simulation. The surface roughness of Co thin films with a thickness of less than 20 nm on borate glasses is shown to be as small as 0.18 nm, at the same scanning scale as the Co film thickness, and the squareness of the hysteresis loop is shown to be as large as 0.96-1.0. As a result of the establishment of polishing techniques for Co thin-film electrodes sandwiched between borate glasses, we successfully demonstrate the formation of smooth Co edges and the generation of stray magnetic fields from Co edges. Theoretical calculation reveals that a strong stray field beyond 6 kOe is generated when the Co thickness is greater than 10 nm at a junction gap distance of 5 nm. From these experimental and calculation results, it can be concluded that SQC devices with a Co thickness of 10-20 nm can be expected to function as spin-filter devices.

  15. Content Model Use and Development to Redeem Thin Section Records

    NASA Astrophysics Data System (ADS)

    Hills, D. J.

    2014-12-01

    The National Geothermal Data System (NGDS) is a catalog of documents and datasets that provide information about geothermal resources located primarily within the United States. The goal of NGDS is to make large quantities of geothermal-relevant geoscience data available to the public by creating a national, sustainable, distributed, and interoperable network of data providers. The Geological Survey of Alabama (GSA) has been a data provider in the initial phase of NGDS. One method by which NGDS facilitates interoperability is through the use of content models. Content models provide a schema (structure) for submitted data. Schemas dictate where and how data should be entered. Content models use templates that simplify data formatting to expedite use by data providers. These methodologies implemented by NGDS can extend beyond geothermal data to all geoscience data. The GSA, using the NGDS physical samples content model, has tested and refined a content model for thin sections and thin section photos. Countless thin sections have been taken from oil and gas well cores housed at the GSA, and many of those thin sections have related photomicrographs. Record keeping for these thin sections has been scattered at best, and it is critical to capture their metadata while the content creators are still available. A next step will be to register the GSA's thin sections with SESAR (System for Earth Sample Registration) and assign an IGSN (International Geo Sample Number) to each thin section. Additionally, the thin section records will be linked to the GSA's online record database. When complete, the GSA's thin sections will be more readily discoverable and have greater interoperability. Moving forward, the GSA is implementing use of NGDS-like content models and registration with SESAR and IGSN to improve collection maintenance and management of additional physical samples.

  16. Sickness certification for patients with acute cough/LRTI in primary care in Poland and Norway

    PubMed Central

    Godycki-Cwirko, Maciek; Nocun, Marek; Butler, Christopher C; Muras, Magdalena; Fleten, Nils; Melbye, Hasse

    2011-01-01

    Objective To compare the frequency and duration of sickness certificates issued by GPs to Polish and Norwegian working adults with acute cough/lower respiratory tract infection (LRTI). Design Cross-sectional observational study with clinicians from nine primary care centres in Poland and 11 primary care centres in Norway. GPs filled out a case report form for all patients, including information on antibiotic prescribing, sickness certification, and advice to stay off work. Setting Primary care research networks in Poland and Norway. Subjects Working adults with a new or worsening cough or clinical presentation suggestive of LRTI. Main outcome measures Issuing sickness certificates and advising patients to stay off work. Results GPs recorded similar symptoms and signs in patients in the two countries. Antibiotics were prescribed more often in Polish than in Norwegian patients (70.4% vs. 27.1%, p < 0.0001). About half of the patients received a formal sickness certificate (50.5% in Norway and 52.0% in Poland). The proportion of patients advised to stay off work was significantly higher in the Polish sample compared with the Norwegian sample (75.2% vs. 56.1%, p = 0.002). Norwegian GPs less often issued sick certificates for more than seven days (5.6% vs. 36.9%, p < 0.0001). Conclusion The overall proportion of sickness certification for acute cough/LRTI was similar in Norwegian and Polish patients. However, in the Polish sample, GPs more often advised patients to take time off work without issuing a sick note. When sickness certificates were issued, duration of longer than seven days was more common in Polish than in Norwegian patients. PMID:21189105

  17. Measurement of surface roughness changes of unpolished and polished enamel following erosion

    PubMed Central

    Austin, Rupert S.; Parkinson, Charles R.; Hasan, Adam; Bartlett, David W.

    2017-01-01

    Objectives To determine if Sa roughness data from measuring one central location of unpolished and polished enamel were representative of the overall surfaces before and after erosion. Methods Twenty human enamel sections (4x4 mm) were embedded in bis-acryl composite and randomised to either a native or polishing enamel preparation protocol. Enamel samples were subjected to an acid challenge (15 minutes 100 mL orange juice, pH 3.2, titratable acidity 41.3mmol OH/L, 62.5 rpm agitation, repeated for three cycles). Median (IQR) surface roughness [Sa] was measured at baseline and after erosion from both a centralised cluster and four peripheral clusters. Within each cluster, five smaller areas (0.04 mm2) provided the Sa roughness data. Results For both unpolished and polished enamel samples there were no significant differences between measuring one central cluster or four peripheral clusters, before and after erosion. For unpolished enamel the single central cluster had a median (IQR) Sa roughness of 1.45 (2.58) μm and the four peripheral clusters had a median (IQR) of 1.32 (4.86) μm before erosion; after erosion there were statistically significant reductions to 0.38 (0.35) μm and 0.34 (0.49) μm respectively (p<0.0001). Polished enamel had a median (IQR) Sa roughness 0.04 (0.17) μm for the single central cluster and 0.05 (0.15) μm for the four peripheral clusters which statistically significantly increased after erosion to 0.27 (0.08) μm for both (p<0.0001). Conclusion Measuring one central cluster of unpolished and polished enamel was representative of the overall enamel surface roughness, before and after erosion. PMID:28771562

  18. Analysis and comparison of focused ion beam milling and vibratory polishing sample surface preparation methods for porosity study of U-Mo plate fuel for research and test reactors.

    PubMed

    Westman, Bjorn; Miller, Brandon; Jue, Jan-Fong; Aitkaliyeva, Assel; Keiser, Dennis; Madden, James; Tucker, Julie D

    2018-07-01

    Uranium-Molybdenum (U-Mo) low enriched uranium (LEU) fuels are a promising candidate for the replacement of high enriched uranium (HEU) fuels currently in use in a high power research and test reactors around the world. Contemporary U-Mo fuel sample preparation uses focused ion beam (FIB) methods for analysis of fission gas porosity. However, FIB possess several drawbacks, including reduced area of analysis, curtaining effects, and increased FIB operation time and cost. Vibratory polishing is a well understood method for preparing large sample surfaces with very high surface quality. In this research, fission gas porosity image analysis results are compared between samples prepared using vibratory polishing and FIB milling to assess the effectiveness of vibratory polishing for irradiated fuel sample preparation. Scanning electron microscopy (SEM) imaging was performed on sections of irradiated U-Mo fuel plates and the micrographs were analyzed using a fission gas pore identification and measurement script written in MatLab. Results showed that the vibratory polishing method is preferentially removing material around the edges of the pores, causing the pores to become larger and more rounded, leading to overestimation of the fission gas porosity size. Whereas, FIB preparation tends to underestimate due to poor micrograph quality and surface damage leading to inaccurate segmentations. Despite the aforementioned drawbacks, vibratory polishing remains a valid method for porosity analysis sample preparation, however, improvements should be made to reduce the preferential removal of material surrounding pores in order to minimize the error in the porosity measurements. Copyright © 2018 Elsevier Ltd. All rights reserved.

  19. Surface quality of silicon wafer improved by hydrodynamic effect polishing

    NASA Astrophysics Data System (ADS)

    Peng, Wenqiang; Guan, Chaoliang; Li, Shengyi

    2014-08-01

    Differing from the traditional pad polishing, hydrodynamic effect polishing (HEP) is non-contact polishing with the wheel floated on the workpiece. A hydrodynamic lubricated film is established between the wheel and the workpiece when the wheel rotates at a certain speed in HEP. Nanoparticles mixed with deionized water are employed as the polishing slurry, and with action of the dynamic pressure, nanoparticles with high chemisorption due to the high specific surface area can easily reacted with the surface atoms forming a linkage with workpiece surface. The surface atoms are dragged away when nanoparticles are transported to separate by the flow shear stress. The development of grand scale integration put extremely high requirements on the surface quality on the silicon wafer with surface roughness at subnanometer and extremely low surface damage. In our experiment a silicon sample was processed by HEP, and the surface topography before and after polishing was observed by the atomic force microscopy. Experiment results show that plastic pits and bumpy structures on the initial surface have been removed away clearly with the removal depth of 140nm by HEP process. The processed surface roughness has been improved from 0.737nm RMS to 0.175nm RMS(10μm×10μm) and the section profile shows peaks of the process surface are almost at the same height. However, the machining ripples on the wheel surface will duplicate on the silicon surface under the action of the hydrodynamic effect. Fluid dynamic simulation demonstrated that the coarse surface on the wheel has greatly influence on the distribution of shear stress and dynamic pressure on the workpiece surface.

  20. A microfluidic approach to water-rock interactions using thin rock sections: Pb and U sorption onto thin shale and granite sections.

    PubMed

    Oh, Youn Soo; Jo, Ho Young; Ryu, Ji-Hun; Kim, Geon-Young

    2017-02-15

    The feasibility of using microfluidic tests to investigate water-rock (mineral) interactions in fractures regarding sorption onto thin rock sections (i.e., shale and granite) of lead (Pb) and uranium (U) was evaluated using a synthetic PbCl 2 solution and uranium-containing natural groundwater as fluids. Effluent composition and element distribution on the thin rock sections before and after microfluidic testing were analyzed. Most Pb removal (9.8mg/cm 2 ) occurred within 3.5h (140 PVF), which was 74% of the total Pb removal (13.2mg/cm 2 ) at the end of testing (14.5h, 560 PVF). Element composition on the thin shale sections determined by μ-XRF analysis indicated that Pb removal was related primarily to Fe-containing minerals (e.g., pyrite). Two thin granite sections (biotite rich, Bt-R and biotite poor, Bt-P) exhibited no marked difference in uranium removal capacity, but a slightly higher amount of uranium was removed onto the thin Bt-R section (266μg/cm 2 ) than the thin Bt-P section (240μg/cm 2 ) within 120h (4800 PVF). However, uranium could not be detected by micro X-ray fluorescence (μ-XRF) analysis, likely due to the detection limit. These results suggest that microfluidic testing on thin rock sections enables quantitative evaluation of rock (mineral)-water interactions at the micro-fracture or pore scale. Copyright © 2016 Elsevier B.V. All rights reserved.

  1. Lavras do Sul: A New Equilibrated Ordinary L5 Chondrite from Rio Grande do Sul, Brazil

    NASA Astrophysics Data System (ADS)

    Zucolotto, M. E.; Antonello, L. L.; Varela, M. E.; Scorzelli, R. B.; Ludka, Isabel P.; Munayco, P.; dos Santos, E.

    2012-03-01

    The new Brazilian chondrite, Lavras do Sul, was found in 1985 at Lavras do Sul, Rio Grande do Sul State-Brazil (33°30'48″S; 53°54'65″W). It consists of a single mass weighing about 1 kg, covered by a black fusion crust with grayish interior. Four polished thin sections were prepared from a slice weighing 67 g on deposit at the Museu Nacional/UFRJ. It consists mostly of chondrules and chondrule fragments dispersed in a recrystallized matrix. Most chondrules are poorly defined and range in size from 300 to 2,000 μm, although some of them show distinct outlines, particularly when viewed under cross-polarized transmitted and reflected light. The texture of chondrules varies from non-porphyritic (e.g., barred-olivine, radial-pyroxene) to porphyritic ones (e.g., granular olivine as well as olivine-pyroxene). The meteorite contains mainly olivine (Fa24.9), low-Ca pyroxene (Fs22.6) and metal phases, with minor amounts of plagioclase, chromite and magnetite. Mössbauer Spectroscopy studies indicate that the metal phase is kamacite, tetrataenite and antitaenite. Veins of secondary iddingsite crosscut the thin section and some ferromagnesian silicates. The chemical composition indicates that Lavras do Sul is a member of the low iron L chondrite group. The poorly delineated chondritic texture with few well-defined chondrules, the occurrence of rare clinopyroxene and plagioclase (and maskelynite) with apparent diameters ranging from 5 to 123 μm led us to classify Lavras do Sul as an equilibrated petrologic type 5. The shock features of some minerals suggest a shock stage S3, and the presence of a small amount of secondary minerals such as iddingsite and goethite, a degree of weathering W1. The meteorite name was approved by the Nomenclature Committee (Nom Com) of the Meteoritical Society (Meteoritic Bulletin Nº99).

  2. Application of Scanning-Imaging X-Ray Microscopy to Fluid Inclusion Candidates in Carbonates of Carbonaceous Chondrites

    NASA Technical Reports Server (NTRS)

    Tsuchiyama, Akira; Nakano, Tsukasa; Miyake, Akira; Akihisa, Takeuchi; Uesugi, Kentaro; Suzuki, Yoshio; Kitayama, Akira; Matsuno, Junya; Zolensky, Michael E.

    2016-01-01

    In order to search for such fluid inclusions in carbonaceous chondrites, a nondestructive technique using x-ray micro-absorption tomography combined with FIB sampling was developed and applied to a carbonaceous chondrite. They found fluid inclusion candidates in calcite grains, which were formed by aqueous alteration. However, they could not determine whether they are really aqueous fluids or merely voids. Phase and absorption contrast images can be simultaneously obtained in 3D by using scanning-imaging x-ray microscopy (SIXM). In refractive index, n=1-sigma+i(beta), in the real part, 1-sigma is the refractive index with decrement, sigma, which is nearly proportional to the density, and the imaginary part, beta, is the extinction coefficient, which is related to the liner attenuation coefficient, mu. Many phases, including water and organic materials as well as minerals, can be identified by SIXM, and this technique has potential availability for Hayabusa-2 sample analysis too. In this study, we examined quantitative performance of d and m values and the spatial resolution in SIXM by using standard materials, and applied this technique to carbonaceous chondrite samples. We used POM ([CH2O]n), silicon, quartz, forsterite, corundum, magnetite and nickel as standard materials for examining the sigma and mu values. A fluid inclusion in terrestrial quartz and bi-valve shell (Atrina vexillum), which are composed of calcite and organic layers with different thickness, were also used for examining the spatial resolution. The Ivuna (CI) and Sutter's Mill (CM) meteorites were used as carbonaceous chondrite samples. Rod- or cube-shaped samples 20-30 micron in size were extracted by using FIB from cross-sectional surfaces of the standard materials or polished thin sections of the chondrites, which was previously observed with SEM. Then, the sample was attached to a thin W-needle and imaged by SIXM system at beamline BL47XU, SPring-8, Japan. The slice thickness was 109.3 nm and the pixel size was mostly 100 nm.

  3. Relation between sick leave and selected exposure variables among women semiconductor workers in Malaysia

    PubMed Central

    Chee, H; Rampal, K

    2003-01-01

    Aims: To determine the relation between sick leave and selected exposure variables among women semiconductor workers. Methods: This was a cross sectional survey of production workers from 18 semiconductor factories. Those selected had to be women, direct production operators up to the level of line leader, and Malaysian citizens. Sick leave and exposure to physical and chemical hazards were determined by self reporting. Three sick leave variables were used; number of sick leave days taken in the past year was the variable of interest in logistic regression models where the effects of age, marital status, work task, work schedule, work section, and duration of work in factory and work section were also explored. Results: Marital status was strongly linked to the taking of sick leave. Age, work schedule, and duration of work in the factory were significant confounders only in certain cases. After adjusting for these confounders, chemical and physical exposures, with the exception of poor ventilation and smelling chemicals, showed no significant relation to the taking of sick leave within the past year. Work section was a good predictor for taking sick leave, as wafer polishing workers faced higher odds of taking sick leave for each of the three cut off points of seven days, three days, and not at all, while parts assembly workers also faced significantly higher odds of taking sick leave. Conclusion: In Malaysia, the wafer fabrication factories only carry out a limited portion of the work processes, in particular, wafer polishing and the processes immediately prior to and following it. This study, in showing higher illness rates for workers in wafer polishing compared to semiconductor assembly, has implications for the governmental policy of encouraging the setting up of wafer fabrication plants with the full range of work processes. PMID:12660374

  4. Carbonaceous Chondrite Thin Section Preparation

    NASA Technical Reports Server (NTRS)

    Harrington, R.; Righter, K.

    2017-01-01

    Carbonaceous chondrite meteorites have long posed a challenge for thin section makers. The variability in sample hardness among the different types, and sometimes within individual sections, creates the need for an adaptable approach at each step of the thin section making process. This poster will share some of the procedural adjustments that have proven to be successful at the NASA JSC Meteorite Thin Section Laboratory. These adjustments are modifications of preparation methods that have been in use for decades and therefore do not require investment in new technology or materials.

  5. Osseointegration is improved by coating titanium implants with a nanostructured thin film with titanium carbide and titanium oxides clustered around graphitic carbon.

    PubMed

    Veronesi, Francesca; Giavaresi, Gianluca; Fini, Milena; Longo, Giovanni; Ioannidu, Caterina Alexandra; Scotto d'Abusco, Anna; Superti, Fabiana; Panzini, Gianluca; Misiano, Carlo; Palattella, Alberto; Selleri, Paolo; Di Girolamo, Nicola; Garbarino, Viola; Politi, Laura; Scandurra, Roberto

    2017-01-01

    Titanium implants coated with a 500nm nanostructured layer, deposited by the Ion Plating Plasma Assisted (IPPA) technology, composed of 60% graphitic carbon, 25% titanium oxides and 15% titanium carbide were implanted into rabbit femurs whilst into the controlateral femurs uncoated titanium implants were inserted as control. At four time points the animals were injected with calcein green, xylenol orange, oxytetracycline and alizarin. After 2, 4 and 8weeks femurs were removed and processed for histology and static and dynamic histomorphometry for undecalcified bone processing into methylmethacrylate, sectioned, thinned, polished and stained with Toluidine blue and Fast green. The overall bone-implant contacts rate (percentage of bone-implant contacts/weeks) of the TiC coated implant was 1.6 fold than that of the uncoated titanium implant. The histomorphometric analyses confirmed the histological evaluations. More precisely, higher Mineral Apposition Rate (MAR, μm/day) (p<0.005) and Bone Formation Rate (BFR, μm 2 /μm/day) (p<0.0005) as well as Bone Implant Contact (Bic) and Bone Ingrowth values (p<0.0005) were observed for the TiC coated implants compared to uncoated implants. In conclusion the hard nanostructured TiC layer protects the bulk titanium implant against the harsh conditions of biological tissues and in the same time, stimulating adhesion, proliferation and activity of osteoblasts, induces a better bone-implant contacts of the implant compared to the uncoated titanium implant. Copyright © 2016. Published by Elsevier B.V.

  6. Synchrotron X-Ray Diffraction Analysis of Meteorites in Thin Section: Preliminary Results

    NASA Technical Reports Server (NTRS)

    Treiman, A. H.; Lanzirotti, A.; Xirouchakis, D.

    2004-01-01

    X-ray diffraction is the pre-eminent technique for mineral identification and structure determination, but is difficult to apply to grains in thin section, the standard meteorite preparation. Bright focused X-ray beams from synchrotrons have been used extensively in mineralogy and have been applied to extraterrestrial particles. The intensity and small spot size achievable in synchrotron X-ray beams makes them useful for study of materials in thin sections. Here, we describe Synchrotron X-ray Diffraction (SXRD) in thin section as done at the National Synchrotron Light Source, and cite examples of its value for studies of meteorites in thin section.

  7. 40 CFR 63.11505 - What parts of my plant does this subpart cover?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... subpart cover? 63.11505 Section 63.11505 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Plating and Polishing Operations Applicability and Compliance Dates § 63.11505 What parts of my plant does... section, at all times. A new source is defined in § 63.11511, “What definitions apply to this subpart?” (1...

  8. 40 CFR 63.11505 - What parts of my plant does this subpart cover?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... subpart cover? 63.11505 Section 63.11505 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Plating and Polishing Operations Applicability and Compliance Dates § 63.11505 What parts of my plant does... paragraphs (a)(1) through (3) of this section, at all times. A new source is defined in § 63.11511, “What...

  9. 40 CFR 63.11505 - What parts of my plant does this subpart cover?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... subpart cover? 63.11505 Section 63.11505 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Plating and Polishing Operations Applicability and Compliance Dates § 63.11505 What parts of my plant does... paragraphs (a)(1) through (3) of this section, at all times. A new source is defined in § 63.11511, “What...

  10. 40 CFR 63.11505 - What parts of my plant does this subpart cover?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... subpart cover? 63.11505 Section 63.11505 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Plating and Polishing Operations Applicability and Compliance Dates § 63.11505 What parts of my plant does... paragraphs (a)(1) through (3) of this section, at all times. A new source is defined in § 63.11511, “What...

  11. The Role of Nanodiamonds in the Polishing Zone During Magnetorheological Finishing (MRF)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    DeGroote, J.E.; Marino, A.E.; WIlson, J.P.

    2008-01-07

    In this work we discuss the role that nanodiamond abrasives play in magnetorheological finishing. We hypothesize that, as the nanodiamond MR fluid is introduced to the magnetic field, the micron sized spherical carbonyl iron (CI) particles are pulled down towards the rotating wheel, leaving a thin layer of nanodiamonds at the surface of the stiffened MR fluid ribbon. Our experimental results shown here support this hypothesis. We also show that surface roughness values inside MRF spots show a strong correlation with the near surface mechanical properties of the glass substrates and with drag force.

  12. Experiences of adult patients using primary care services in Poland - a cross-sectional study in QUALICOPC study framework.

    PubMed

    Oleszczyk, Marek; Krztoń-Królewiecka, Anna; Schäfer, Willemijn L A; Boerma, Wienke G W; Windak, Adam

    2017-11-22

    Patients as real healthcare system users are important observers of primary care and are able to provide reliable information about the quality of care. The aim of this study was to explore the patients' experiences and their level of satisfaction with the process and outcomes of care provided by primary care physicians in Poland and to identify the characteristics of the patients, their physicians, and facilities associated with patient satisfaction. The study is based on data from the Polish part of the Quality and Costs of Primary Care in Europe (QUALICOPC) cross-sectional, questionnaire-based study. In Poland, a nationally representative sample of 220 PC physicians and 1980 of their patients were recruited to take part in the study. As a study tool we used 3 out of 4 QUALICOPC questionnaires: "Patient Experience", "PC Physician" and "Fieldworker" questionnaires. The areas of the best quality perceived by Polish PC patients are: equity, accessibility of care and quality of service. Coordination and comprehensiveness of care are evaluated relatively worse. The patients' and their physicians' characteristics have a limited influence on patient satisfaction and experiences with Polish primary care. Primary health care in Poland is of good overall quality as perceived by the patients. Study participants were at most satisfied with accessibility and equity of care and less satisfied with coordination and comprehensiveness of care. Longer patient-doctor relationship and older age of patients were found as the most influential determinants of higher satisfaction. However, variables used in this study poorly explain the overall level of satisfaction. Further research is needed to identify the other determinants of patient satisfaction in the Polish population. Rural practices deserve additional attention due to highest proportions of both extremely satisfied and dissatisfied patients.

  13. Treatment guidelines for Circadian Rhythm Sleep-Wake Disorders of the Polish Sleep Research Society and the Section of Biological Psychiatry of the Polish Psychiatric Association. Part I. Physiology, assessment and therapeutic methods.

    PubMed

    Wichniak, Adam; Jankowski, Konrad S; Skalski, Michal; Skwarło-Sońta, Krystyna; Zawilska, Jolanta B; Żarowski, Marcin; Poradowska, Ewa; Jernajczyk, Wojciech

    2017-10-29

    Majority of the physiological processes in the human organism are rhythmic. The most common are the diurnal changes that repeat roughly every 24 hours, called circadian rhythms. Circadian rhythms disorders have negative influence on human functioning. The aim of this article is to present the current understanding of the circadian rhythms physiological role, with particular emphasis on the circadian rhythm sleep-wake disorders (CRSWD), principles of their diagnosis and chronobiological therapy. The guidelines are based on the review of recommendations from the scientific societies involved in sleep medicine and the clinical experiences of the authors. Researchers participating in the preparation of guidelines were invited by the Polish Sleep Research Society and the Section of Biological Psychiatry of the Polish Psychiatric Association, based on their significant contributions in circadian rhythm research and/or clinical experience in the treatment of such disorders. Finally, the guidelines were adjusted to the questions and comments given by the members of both Societies. CRSWD have a significant negative impact on human health and functioning. Standard methods used to assess CRSWD are sleep diaries and sleep logs, while the actigraphy, when available, should be also used. The most effective methods of CRSWD treatment are melatonin administration and light therapy. Behavioral interventions are also recommended. Afourteen-day period of sleep-wake rhythm assessment in CRSWD enables accurate diagnosis, adequate selection of chronobiological interventions, and planning adequate diurnal timing of their application. This type of assessment is quite easy, low-cost, and provides valuable indications how to adjust the therapeutic approach to the circadian phase of the particular patient.

  14. Treatment guidelines for Circadian Rhythm Sleep - Wake Disorders of the Polish Sleep Research Society and the Section of Biological Psychiatry of the Polish Psychiatric Association. Part II. Diagnosis and treatment.

    PubMed

    Wichniak, Adam; Jankowski, Konrad S; Skalski, Michał; Skwarło-Sońta, Krystyna; Zawilska, Jolanta B; Żarowski, Marcin; Poradowska, Ewa; Jernajczyk, Wojciech

    2017-10-29

    Circadian rhythm sleep-wake disorders (CRSWD) are a group of disorders, in which the timing of sleep and wakefulness significantly differs from a patient's expectations or socially acceptable times. The aimof the article is to present the current principles for the diagnosis and treatment of CRSWD in adults and children. Guidelines proposed as CRSWD treatment standard are based on the recommendations from the scientific societies involved in the sleep research and medicine. Researchers participating in the guidelines preparation were invited by the Polish Sleep Research Society and the Section of Biological Psychiatry of the Polish Psychiatric Association based on their significant contribution to the circadian rhythm research and/or clinical experience in the treatment of these disorders. Finally, the guidelines were adjusted to the questions and comments given by the members of both Societies. Patients with endogenous CRSWD are often misdiagnosed and treated for insomnia or hypersomnia. Therefore, each patient reporting sleep-wake disorders should be interviewed about the quality of sleep and its timing during free days (e.g. weekends, holidays). Avalid CRSWD diagnosis can be also established by using sleep diaries/logs and actigraphy. The treatment of choice for CRSWD is chronotherapy, which involves melatonin application, light therapy, and behavioral interventions. Sleep disorders associated with shift work and time zone changes are a growing health problem. Interventions for these disorders should primarily focus on prevention. The main problem in the treatment of CRSWD is an invalid diagnosis. Hypnotics and/or psychostimulants are often used instead of chronotherapeutic interventions, what can alleviate symptoms but is not an effective treatment.

  15. Benefit of computer-aided detection analysis for the detection of subsolid and solid lung nodules on thin- and thick-section CT.

    PubMed

    Godoy, Myrna C B; Kim, Tae Jung; White, Charles S; Bogoni, Luca; de Groot, Patricia; Florin, Charles; Obuchowski, Nancy; Babb, James S; Salganicoff, Marcos; Naidich, David P; Anand, Vikram; Park, Sangmin; Vlahos, Ioannis; Ko, Jane P

    2013-01-01

    The objective of our study was to evaluate the impact of computer-aided detection (CAD) on the identification of subsolid and solid lung nodules on thin- and thick-section CT. For 46 chest CT examinations with ground-glass opacity (GGO) nodules, CAD marks computed using thin data were evaluated in two phases. First, four chest radiologists reviewed thin sections (reader(thin)) for nodules and subsequently CAD marks (reader(thin) + CAD(thin)). After 4 months, the same cases were reviewed on thick sections (reader(thick)) and subsequently with CAD marks (reader(thick) + CAD(thick)). Sensitivities were evaluated. Additionally, reader(thick) sensitivity with assessment of CAD marks on thin sections was estimated (reader(thick) + CAD(thin)). For 155 nodules (mean, 5.5 mm; range, 4.0-27.5 mm)-74 solid nodules, 22 part-solid (part-solid nodules), and 59 GGO nodules-CAD stand-alone sensitivity was 80%, 95%, and 71%, respectively, with three false-positives on average (0-12) per CT study. Reader(thin) + CAD(thin) sensitivities were higher than reader(thin) for solid nodules (82% vs 57%, p < 0.001), part-solid nodules (97% vs 81%, p = 0.0027), and GGO nodules (82% vs 69%, p < 0.001) for all readers (p < 0.001). Respective sensitivities for reader(thick), reader(thick) + CAD(thick), reader(thick) + CAD(thin) were 40%, 58% (p < 0.001), and 77% (p < 0.001) for solid nodules; 72%, 73% (p = 0.322), and 94% (p < 0.001) for part-solid nodules; and 53%, 58% (p = 0.008), and 79% (p < 0.001) for GGO nodules. For reader(thin), false-positives increased from 0.64 per case to 0.90 with CAD(thin) (p < 0.001) but not for reader(thick); false-positive rates were 1.17, 1.19, and 1.26 per case for reader(thick), reader(thick) + CAD(thick), and reader(thick) + CAD(thin), respectively. Detection of GGO nodules and solid nodules is significantly improved with CAD. When interpretation is performed on thick sections, the benefit is greater when CAD marks are reviewed on thin rather than thick sections.

  16. Effects of instrumentation time on microleakage of resin-modified glass ionomer cements.

    PubMed

    Yap, Adrian U J; Yeo, Egwin J C; Yap, W Y; Ong, Debbie S B; Tan, Jane W S

    2003-01-01

    This study investigated the effect of instrumentation time on the microleakage of resin-modified glass ionomer cements (RMGICs). Class V cavities were prepared on buccal and lingual/ palatal surfaces of 64 freshly extracted non-carious premolars. The cavities on each tooth were restored with Fuji II LC (FT [GC]) and Photac-Fil Quick (PF [3M-ESPE]). The restored teeth were randomly divided into two groups of 32 teeth. Finishing/polishing was done immediately after light-polymerization in one group and was delayed for one week in the other group. The following finishing/polishing systems were evaluated: (a) Robot Carbides (RC); (b) SuperSnap (SS); (c) OneGloss (OG) and (d) CompoSite Polishers (CS). The sample size for each instrumentation time, material and finishing/polishing system combination was 8. Storage medium for both immediate and delayed instrumentation groups was distilled water at 37 degrees C during the hiatus period. The teeth were subsequently subjected to dye penetration testing (0.5% basic fushcin), sectioned and scored. Data were analyzed using Kruskal-Wallis and Mann-Whitney U tests at significance level 0.05. For PF, significant difference in enamel leakage was observed between immediate and delayed instrumentation with SS and CS. Significant differences in dentin leakage were also observed between the two instrumentation times for SS. For FT, significant differences in leakage between instrumentation times were observed only in dentin and with RC. Where significant differences in dye penetration scores existed, delayed finishing/polishing resulted in less microleakage.

  17. Measurements and Studies of Secondary Electron Emission of Diamond Amplified Photocathode

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wu,Q.

    2008-10-01

    The Diamond Amplified Photocathode (DAP) is a novel approach to generating electrons. By following the primary electron beam, which is generated by traditional electron sources, with an amplifier, the electron beam available to the eventual application is increased by 1 to 2 orders of magnitude in current. Diamond has a very wide band gap of 5.47eV which allows for a good negative electron affinity with simple hydrogenation, diamond can hold more than 2000MV/m field before breakdown. Diamond also provides the best rigidity among all materials. These two characters offer the capability of applying high voltage across very thin diamond filmmore » to achieve high SEY and desired emission phase. The diamond amplifier also is capable of handling a large heat load by conduction and sub-nanosecond pulse input. The preparation of the diamond amplifier includes thinning and polishing, cleaning with acid etching, metallization, and hydrogenation. The best mechanical polishing available can provide high purity single crystal diamond films with no less than 100 {micro}m thickness and <15 nm Ra surface roughness. The ideal thickness for 700MHz beam is {approx}30 {micro}m, which requires further thinning with RIE or laser ablation. RIE can achieve atomic layer removal precision and roughness eventually, but the time consumption for this procedure is very significant. Laser ablation proved that with <266nm ps laser beam, the ablation process on the diamond can easily achieve removing a few microns per hour from the surface and <100nm roughness. For amplifier application, laser ablation is an adequate and efficient process to make ultra thin diamond wafers following mechanical polishing. Hydrogenation will terminate the diamond surface with monolayer of hydrogen, and form NEA so that secondary electrons in the conduction band can escape into the vacuum. The method is using hydrogen cracker to strike hydrogen atoms onto the bare diamond surface to form H-C bonds. Two independent experiments were carried out to determine the transport of the electrons within the diamond and their emission at the surface. In transmission mode measurements, the diamond amplifier was coated with metal on both sides, so results simply depend only on the electron transport within the diamond. The SEY for this mode provides one secondary electron per 20eV energy, which gives the gain of more than 200 for 4.7keV (effective energy) primary electrons under 2MV/m. Laser detrapping can help the signal maintain the gain with lops pulse and duty cycle of 1.67 x 10{sup -7}. In emission mode measurements, in which the diamond is prepared as in the actual application, the SEY is {approx}20 for 700eV (effective energy) primary electrons under 1.21MV/m. The electric field applied and the primary electron energy is limited by the experiment setup, but the results show good trend toward large gain under high field. Thermal emittance of the diamond secondary emission is critical for the beam application. A careful design is setup to measure with very fine precision and accuracy of 0.01eV.« less

  18. Development of a High Resolution-High Sensitivity Ion Microprobe Facility for Cosmochemical Applications

    NASA Technical Reports Server (NTRS)

    McKeegan, Kevin D.

    1998-01-01

    NASA NAGW-4112 has supported development of the CAMECA ims 1270 ion microprobe at UCLA for applications in cosmochemistry. The instrument has been brought to an operational status and techniques developed for accurate, precise microbeam analysis of oxygen isotope ratios in polished thin-sections. We made the first oxygen isotopic (delta(18)O and delta(17)O) measurements of rare mafic silicates in the most chemically primitive meteorites, the a chondrites (Leshin et al., 1997). The results have implications for both high temperature processing in the nebula and low-T aqueous alteration on the CI asteroid. We have performed measurements of oxygen isotopic compositions of magnetite and co-existing olivine from carbonaceous (Choi et al., 1997) and unequilibrated ordinary chondrites (Choi et al., in press). This work has identified a significant new oxygen isotope reservoir in the early solar system: water characterized by a very high Delta(17)) value of approx. 5 % per thousand. We have determined the spatial distributions of oxygen isotopic anomalies in all major mineral phases of a type B CAI from Allende. We have also studied an unusual fractionated CAI from Leoville and made the first oxygen isotopic measurements in rare CAIs from ordinary chondrites.

  19. Attenuation of near-IR light through dentin at wavelengths from 1300–1650-nm

    PubMed Central

    Chan, Andrew C.; Darling, Cynthia L.; Chan, Kenneth H.; Fried, Daniel

    2014-01-01

    Light scattering in dental enamel decreases markedly from the UV to the near-IR and recent studies employing near-IR transillumination and reflectance imaging including optical coherence tomography indicate that this wavelength region is ideally suited for imaging dental caries due to the high transparency of enamel. The opacity of dentin is an important factor in optimizing the contrast of demineralization in reflectance measurements. It also influences the contrast of occlusal lesions in transillumination. Light scattering in dentin is an order of magnitude larger than in enamel, it is highly anisotropic and has a different spectral light scattering dependence than enamel. The objective of this study was to measure the optical attenuation of near-IR light through dentin at near-IR wavelengths from 1300–1650-nm. In this study the collimated transmission of near-IR light through polished thin sections of dentin of 0.05 to 0.6 mm thickness was measured. Beer-Lambert plots show that the attenuation coefficients range in magnitude from 20 to 40 cm−1. Attenuation increased significantly with increasing wavelength and the increases were not entirely consistent with increased water absorption. PMID:24839373

  20. Thermal Cycling and High-Temperature Corrosion Tests of Rare Earth Silicate Environmental Barrier Coatings

    NASA Astrophysics Data System (ADS)

    Darthout, Émilien; Gitzhofer, François

    2017-12-01

    Lutetium and yttrium silicates, enriched with an additional secondary zirconia phase, environmental barrier coatings were synthesized by the solution precursor plasma spraying process on silicon carbide substrates. A custom-made oven was designed for thermal cycling and water vapor corrosion testing. The oven can test four specimens simultaneously and allows to evaluate environmental barrier performances under similar corrosion kinetics compared to turbine engines. Coatings structural evolution has been observed by SEM on the polished cross sections, and phase composition has been analyzed by XRD. All coatings have been thermally cycled between 1300 °C and the ambient temperature, without spallation, due to their porosity and the presence of additional secondary phase which increases the thermal cycling resistance. During water vapor exposure at 1200 °C, rare earth disilicates showed a good stability, which is contradictory with the literature, due to impurities—such as Si- and Al-hydroxides—in the water vapor jets. The presence of vertical cracks allowed the water vapor to reach the substrate and then to corrode it. It has been observed that thin vertical cracks induced some spallation after 24 h of corrosion.

  1. Computer-Controlled Cylindrical Polishing Process for Development of Grazing Incidence Optics for Hard X-Ray Region

    NASA Technical Reports Server (NTRS)

    Khan, Gufran Sayeed; Gubarev, Mikhail; Speegle, Chet; Ramsey, Brian

    2010-01-01

    The presentation includes grazing incidence X-ray optics, motivation and challenges, mid spatial frequency generation in cylindrical polishing, design considerations for polishing lap, simulation studies and experimental results, future scope, and summary. Topics include current status of replication optics technology, cylindrical polishing process using large size polishing lap, non-conformance of polishin lap to the optics, development of software and polishing machine, deterministic prediction of polishing, polishing experiment under optimum conditions, and polishing experiment based on known error profile. Future plans include determination of non-uniformity in the polishing lap compliance, development of a polishing sequence based on a known error profile of the specimen, software for generating a mandrel polishing sequence, design an development of a flexible polishing lap, and computer controlled localized polishing process.

  2. Chemical Processing Manual

    NASA Technical Reports Server (NTRS)

    Beyerle, F. J.

    1972-01-01

    Chemical processes presented in this document include cleaning, pickling, surface finishes, chemical milling, plating, dry film lubricants, and polishing. All types of chemical processes applicable to aluminum, for example, are to be found in the aluminum alloy section. There is a separate section for each category of metallic alloy plus a section for non-metals, such as plastics. The refractories, super-alloys and titanium, are prime candidates for the space shuttle, therefore, the chemical processes applicable to these alloys are contained in individual sections of this manual.

  3. Study on chemical mechanical polishing of silicon wafer with megasonic vibration assisted.

    PubMed

    Zhai, Ke; He, Qing; Li, Liang; Ren, Yi

    2017-09-01

    Chemical mechanical polishing (CMP) is the primary method to realize the global planarization of silicon wafer. In order to improve this process, a novel method which combined megasonic vibration to assist chemical mechanical polishing (MA-CMP) is developed in this paper. A matching layer structure of polishing head was calculated and designed. Silicon wafers are polished by megasonic assisted chemical mechanical polishing and traditional chemical mechanical polishing respectively, both coarse polishing and precision polishing experiments were carried out. With the use of megasonic vibration, the surface roughness values Ra reduced from 22.260nm to 17.835nm in coarse polishing, and the material removal rate increased by approximately 15-25% for megasonic assisted chemical mechanical polishing relative to traditional chemical mechanical polishing. Average Surface roughness values Ra reduced from 0.509nm to 0.387nm in precision polishing. The results show that megasonic assisted chemical mechanical polishing is a feasible method to improve polishing efficiency and surface quality. The material removal and finishing mechanisms of megasonic vibration assisted polishing are investigated too. Copyright © 2017 Elsevier B.V. All rights reserved.

  4. Surface Plasmon Waves on Thin Metal Films.

    NASA Astrophysics Data System (ADS)

    Craig, Alan Ellsworth

    Surface-plasmon polaritons propagating on thin metal films bounded by dielectrics of nearly equal refractive indexes comprise two bound modes. Calculations indicate that, while the modes are degenerate on thick films, both the real and the imaginary components of the propagation constants for the modes split into two branches on successively thinner films. Considering these non-degenerate modes, the mode exhibiting a symmetric (antisymmetric) transverse profile of the longitudinally polarized electric field component, has propagation constant components both of which increase (decrease) with decreasing film thickness. Theoretical propagation constant eigenvalue (PCE) curves have been plotted which delineate this dependence of both propagation constant components on film thickness. By means of a retroreflecting, hemispherical glass coupler in an attenuated total reflection (ATR) configuration, light of wavelength 632.8 nm coupled to the modes of thin silver films deposited on polished glass substrates. Lorentzian lineshape dips in the plots of reflectance vs. angle of incidence indicate the presence of the plasmon modes. The real and imaginary components of the propagation constraints (i.e., the propagation constant and loss coefficient) were calculated from the angular positions and widths of the ATR resonances recorded. Films of several thicknesses were probed. Results which support the theoretically predicted curves were reported.

  5. Sectioning Coated Specimens Without Edge Rounding

    NASA Technical Reports Server (NTRS)

    Mckechnie, Timothy N.

    1988-01-01

    New method devised for preparation of cross sections of coated specimens for scanning electron microscopy or energy-dispersive analysis without rounding edges of coatings. After cutting and polishing, specimen section remains smooth and flat so it can be examined under high magnification out to edge of coating. Sectioned blade first electroplated with hard nickel 0.003 in., then encapsulated in two layers of material: soft conductive material at bottom and 0.25 in. of hard diallyl phthalate at top. Nickel plate provides electrical path from surface of section to conductive material below.

  6. Electrochemical characterization of bulk and thin film copper in ammonia- and nitric acid-based slurries for chemical mechanical planarization of interconnects

    NASA Astrophysics Data System (ADS)

    Sainio, Carlyn Anne

    Copper will be replacing aluminum as the interconnect material in silicon integrated circuits. Chemical mechanical planarization (CMP) in combination with an inlaid metal interconnection scheme has been utilized to pattern copper interconnects. The thesis describes an attempt to understand the electrochemistry of copper in slurries used for CMP. Steady-state electrochemical potential measurements, linear polarization resistance determinations, and potentiodynamic and potentiostatic polarization scans have been used in order to characterize the mechanism by which copper is removed during CMP. Electrochemical measurements were implemented on a rotating disk assembly to simulate conditions during CMP. Experiments were performed on both bulk copper samples and blanket copper thin films sputter deposited onto silicon wafers. Electrochemical potential measurements have been used in conjunction with potential-pH diagrams to determine the possible copper species which are stable during CMP. Electrochemical results were correlated to CMP experiments to determine slurry compositions with optimum potential-pH ranges for copper planarization. The results indicate that such studies present an opportunity to isolate the electrochemical and chemical effects from the mechanical effects in the CMP of metals and to determine the dependencies of each of these effects on the other. CMP of copper was controlled by the removal of native or non-native surface films. High CMP rates were achieved by matching the rates of film formation and copper and film dissolution. During CMP, surface films are abraded, allowing increased dissolution of copper until the surface film reforms. When the surface was indented by abrasive particles, the corrosion rate of the exposed copper increased by two orders of magnitude. Etchants (i.e. ammonia or nitric acid) were necessary for high CMP rates (120-240 nm/min) and to minimize scratching. CMP rates of copper in 1 volume percent NHsb4OH and 0.7 volume percent HNOsb3 with 0.0016 weight percent KMnOsb4 were comparable. Electrochemical characterization can narrow the possible slurry compositions that may be used for polishing. Also, the possibility of implementing electrochemical techniques to detect the endpoint of polishing was investigated. Although electrochemical measurements in ammonia-based slurries did not indicate when tantalum was exposed, similar measurements may be used to determine when polishing pads should be replaced.

  7. 8 CFR 245.12 - What are the procedures for certain Polish and Hungarian parolees who are adjusting status to...

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... Immigration Reform and Immigrant Responsibility Act of 1996? 245.12 Section 245.12 Aliens and Nationality... adjusting status to that of permanent resident under the Illegal Immigration Reform and Immigrant...

  8. Thin sectioning and surface replication of ice at low temperature.

    USGS Publications Warehouse

    Daley, M.A.; Kirby, S.H.

    1984-01-01

    We have developed a new technique for making thin sections and surface replicas of ice at temperatures well below 273d K. The ability to make thin sections without melting sample material is important in textural and microstructural studies of ice deformed at low temperatures because of annealing effects we have observed during conventional section making.-from Author

  9. Student Use of Thin Sections in Introductory Geology

    ERIC Educational Resources Information Center

    O'Brien, Lawrence

    1978-01-01

    Thin-section photomicrographs are used to introduce the introductory geology laboratory classes to many of the optical properties of minerals. Evaluation by questionnaire suggests that the study of thin sections has a positive effect on the enjoyment and understanding of rock identification and classification by introductory students. (Author/MA)

  10. Publications - GMC 360 | Alaska Division of Geological & Geophysical

    Science.gov Websites

    DGGS GMC 360 Publication Details Title: Photomicrographs of Petrographic Thin Sections for the Inigok Reference Shell International EP, Inc., 2009, Photomicrographs of Petrographic Thin Sections for the Inigok page for information on ordering data on DVD. Keywords Oil and Gas; Petrographic; Thin Section Top of

  11. Publications - GMC 391 | Alaska Division of Geological & Geophysical

    Science.gov Websites

    DGGS GMC 391 Publication Details Title: Core descriptions, photographs and thin section photomicro , Inc., 2010, Core descriptions, photographs and thin section photomicro-graphs from the Humble Oil DDH DVD. Keywords Core Drilling; Thin Section Top of Page Department of Natural Resources, Division of

  12. The Use of Ion Implantation for Materials Processing.

    DTIC Science & Technology

    1980-10-06

    consists of a series of sections, each section being an annular insulator (glass) and a shaped metal electrode (polished aluminum ) cemented together. A...depending on the ion species, semiconductor material, attached materials (such as aluminum leads), implantation energy, and dose; but some devices are...concentration of subsurface carbon. Appearing directly beneath the oxide layer, the C concentration first reaches a maximum of about five times the bulk

  13. Effect of Surface Preparation on the 815°C Oxidation of Single-Crystal Nickel-Based Superalloys

    NASA Astrophysics Data System (ADS)

    Sudbrack, Chantal K.; Beckett, Devon L.; MacKay, Rebecca A.

    2015-11-01

    A primary application for single-crystal superalloys has been jet engine turbine blades, where operation temperatures reach well above 1000°C. The NASA Glenn Research Center is considering use of single-crystal alloys for future, lower temperature application in the rims of jet engine turbine disks. Mechanical and environmental properties required for potential disk rim operation at 815°C are being examined, including the oxidation and corrosion behavior, where there is little documentation at intermediate temperatures. In this study, single-crystal superalloys, LDS-1101+Hf and CMSX-4+Y, were prepared with different surface finishes and compared after isothermal and cyclic oxidation exposures. Surface finish has a clear effect on oxide formation at 815°C. Machined low-stress ground surfaces after exposure for 440 h produce thin Al2O3 external scales, which is consistent with higher temperature oxidation, whereas polished surfaces with a mirror finish yield much thicker NiO external scales with subscale of Cr2O3-spinel-Al2O3, which may offer less reliable oxidation resistance. Additional experiments separate the roles of cold-work, localized deformation, and the extent of polishing and surface roughness on oxide formation.

  14. R&D progress in SRF surface preparation with centrifugal barrel polishing (cbp) for both Nb and Cu

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Palczewski, Ari

    Centrifugal Barrel polishing (CBP) is becoming a common R&D tool for SRF cavity preparation around the world. During the CBP process a cylindrically symmetric SRF cavity is filled with relatively cheap and environmentally friendly abrasive and sealed. The cavity is then spun around a cylindrically symmetric axis at high speeds uniformly conditioning the inner surface. This uniformity is especially relevant for SRF application because many times a single manufacturing defects limits cavity?s performance well below it?s theoretical limit. In addition CBP has created surfaces with roughness?s on the order of 10?s of nm which create a unique surface for wetmore » chemistry or thin film deposition. CBP is now being utilized at Jefferson Laboratory, Fermi Laboratory and Cornell University in the US, Deutsches Elektronen-Synchrotron in Germany, Laboratori Nazionali di Legnaro in Italy, and Raja Ramanna Centre for Advanced Technology in India. In this talk we will present current CBP research from each lab including equipment, baseline recipes, cavity removal rates and subsequent cryogenic cavity tests on niobium as well as copper cavities where available.« less

  15. Influence of Si wafer thinning processes on (sub)surface defects

    NASA Astrophysics Data System (ADS)

    Inoue, Fumihiro; Jourdain, Anne; Peng, Lan; Phommahaxay, Alain; De Vos, Joeri; Rebibis, Kenneth June; Miller, Andy; Sleeckx, Erik; Beyne, Eric; Uedono, Akira

    2017-05-01

    Wafer-to-wafer three-dimensional (3D) integration with minimal Si thickness can produce interacting multiple devices with significantly scaled vertical interconnections. Realizing such a thin 3D structure, however, depends critically on the surface and subsurface of the remaining backside Si after the thinning processes. The Si (sub)surface after mechanical grinding has already been characterized fruitfully for a range of few dozen of μm. Here, we expand the characterization of Si (sub)surface to 5 μm thickness after thinning process on dielectric bonded wafers. The subsurface defects and damage layer were investigated after grinding, chemical mechanical polishing (CMP), wet etching and plasma dry etching. The (sub)surface defects were characterized using transmission microscopy, atomic force microscopy, and positron annihilation spectroscopy. Although grinding provides the fastest removal rate of Si, the surface roughness was not compatible with subsequent processing. Furthermore, mechanical damage such as dislocations and amorphous Si cannot be reduced regardless of Si thickness and thin wafer handling systems. The CMP after grinding showed excellent performance to remove this grinding damage, even though the removal amount is 1 μm. For the case of Si thinning towards 5 μm using grinding and CMP, the (sub)surface is atomic scale of roughness without vacancy. For the case of grinding + dry etch, vacancy defects were detected in subsurface around 0.5-2 μm. The finished surface after wet etch remains in the nm scale in the strain region. By inserting a CMP step in between grinding and dry etch it is possible to significantly reduce not only the roughness, but also the remaining vacancies at the subsurface. The surface of grinding + CMP + dry etching gives an equivalent mono vacancy result as to that of grinding + CMP. This combination of thinning processes allows development of extremely thin 3D integration devices with minimal roughness and vacancy surface.

  16. Locating the electrical junctions in Cu(In,Ga)Se 2 and Cu 2ZnSnSe 4 solar cells by scanning capacitance spectroscopy

    DOE PAGES

    Xiao, Chuanxiao; Jiang, Chun -Sheng; Moutinho, Helio; ...

    2016-08-09

    Here, we determined the electrical junction (EJ) locations in Cu(In,Ga)Se 2 (CIGS) and Cu 2ZnSnSe 4 (CZTS) solar cells with ~20-nm accuracy by developing scanning capacitance spectroscopy (SCS) applicable to the thin-film devices. Cross-sectional sample preparation for the SCS measurement was developed by high-energy ion milling at room temperature for polishing the cross section to make it flat, followed by low-energy ion milling at liquid nitrogen temperature for removing the damaged layer and subsequent annealing for growing a native oxide layer. The SCS shows distinct p-type, transitional, and n-type spectra across the devices, and the spectral features change rapidly withmore » location in the depletion region, which results in determining the EJ with ~20-nm resolution. We found an n-type CIGS in the region next to the CIGS/CdS interface; thus, the cell is a homojunction. The EJ is ~40 nm from the interface on the CIGS side. In contrast, such an n-type CZTS was not found in the CZTS/CdS cells. The EJ is ~20 nm from the CZTS/CdS interface, which is consistent with asymmetrical carrier concentrations of the p-CZTS and n-CdS in a heterojunction cell. Our results of unambiguously determination of the junction locations contribute significantly to understanding the large open-circuit voltage difference between CIGS and CZTS.« less

  17. Locating the electrical junctions in Cu(In,Ga)Se 2 and Cu 2ZnSnSe 4 solar cells by scanning capacitance spectroscopy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Xiao, Chuanxiao; Jiang, Chun -Sheng; Moutinho, Helio

    Here, we determined the electrical junction (EJ) locations in Cu(In,Ga)Se 2 (CIGS) and Cu 2ZnSnSe 4 (CZTS) solar cells with ~20-nm accuracy by developing scanning capacitance spectroscopy (SCS) applicable to the thin-film devices. Cross-sectional sample preparation for the SCS measurement was developed by high-energy ion milling at room temperature for polishing the cross section to make it flat, followed by low-energy ion milling at liquid nitrogen temperature for removing the damaged layer and subsequent annealing for growing a native oxide layer. The SCS shows distinct p-type, transitional, and n-type spectra across the devices, and the spectral features change rapidly withmore » location in the depletion region, which results in determining the EJ with ~20-nm resolution. We found an n-type CIGS in the region next to the CIGS/CdS interface; thus, the cell is a homojunction. The EJ is ~40 nm from the interface on the CIGS side. In contrast, such an n-type CZTS was not found in the CZTS/CdS cells. The EJ is ~20 nm from the CZTS/CdS interface, which is consistent with asymmetrical carrier concentrations of the p-CZTS and n-CdS in a heterojunction cell. Our results of unambiguously determination of the junction locations contribute significantly to understanding the large open-circuit voltage difference between CIGS and CZTS.« less

  18. Assessing the application of tooth cementum annulation relative to macroscopic aging techniques in an archeological sample.

    PubMed

    Gauthier, J; Schutkowski, H

    2013-02-01

    The analysis of human skeletal remains is frequently impeded by the lack of adequately preserved morphological markers on which to base age estimation, particularly in archeological contexts. Therefore, histological methods such as tooth cementum annulation analysis can be useful for extracting reliable age estimates from poorly preserved skeletons, if they produce results corresponding to morphologically based, multifactorial assessments. In order to test this presumption, this study compares tooth cementum annulation (TCA) with macroscopic age estimation results incorporating the Brooks-Suchey pubic symphysis and the Buckberry-Chamberlain revised auricular surface methods, as well as Brothwell's guidelines for analyzing dental attrition. Undecalcified, polished, and unstained transverse thin sections viewed using standard light microscopy, with decentered phase contrast microscopy in cases of poorly delineated cementum annulations, were used for TCA counts. Age estimates were applied independently on the late medieval archeological Box Lane cemetery assemblage from Pontefract, England, to analyze their measure of correspondence and to assess whether data produced by a single histological technique are comparable to information pooled from multiple morphological age markers. Spearman's rank correlation tests resulted in a significant association between TCA and morphological age estimates. Further studies using larger samples of known age material would help to improve our understanding of TCA age estimation performance relative to macroscopic age assessment as well as continued refinement and standardization of cementum sectioning, which is suggested to impact annulation visibility. Copyright © 2012 Elsevier GmbH. All rights reserved.

  19. Method for correcting imperfections on a surface

    DOEpatents

    Sweatt, William C.; Weed, John W.

    1999-09-07

    A process for producing near perfect optical surfaces. A previously polished optical surface is measured to determine its deviations from the desired perfect surface. A multi-aperture mask is designed based on this measurement and fabricated such that deposition through the mask will correct the deviations in the surface to an acceptable level. Various mask geometries can be used: variable individual aperture sizes using a fixed grid for the apertures or fixed aperture sizes using a variable aperture spacing. The imperfections are filled in using a vacuum deposition process with a very thin thickness of material such as silicon monoxide to produce an amorphous surface that bonds well to a glass substrate.

  20. Optical fiber sensors for breathing diagnostics

    NASA Astrophysics Data System (ADS)

    Chen, Q.; Claus, Richard O.; Mecham, Jeffrey B.; Vercellino, M.; Arregui, Francisco J.; Matias, Ignacio R.

    2002-03-01

    We report the application of an optical fiber-based humidity sensor to the problem of breathing diagnostics. The sensor is fabricated by molecularly self-assembling selected polymers and functionalized inorganic nanoclusters into multilayered optical thin films on the cleaved and polished flat end of a singlemode optical fiber. Prior work has studied the synthesis process and the fundamental mechanisms responsible for the change in optical reflection from the film that occurs as a function of humidity. We will briefly review that prior work as a way to introduce more recent developments. This paper will then discuss the application of these sensors to the analysis of air flow. We have designed the sensor thin film materials for the detection of relative humidity over a wide range, from approximately 10 to 95%, and for response times as short as several tens of milliseconds. This very fast response time allows the near real-time analysis of air flow and humidity during a single breath, with the advantage of very small size.

  1. Partial analysis of experiment LDEF A-0114

    NASA Technical Reports Server (NTRS)

    Gregory, J. C.

    1986-01-01

    Due to delays in manifesting the return of the Long Duration Exposure Facility from space, attention was concentrated on extracting the maximum information from the EIOM-2 (oxygen interaction with materials experiment) flown on STS-8 in September 1983. An analysis was made of the optical surfaces exposed during that flight and an assessment made of the effect of the 5 eV atomic oxygen upon their physical and chemical properties. The surfaces studied were of two types: high-purity thin films sputtered or evaporated onto 2.54-cm diam lambda/20 fused silica optical flats, and highly polished bulk samples. Rapid etching of carbon and carbonaceous surfaces was observed with polycarbonate CR-39 showing the largest etch of any substrate flown and measured. Of the metals tested, only osmium and silver showed large effects, the former being heavily etched and the later forming a very thick layer of oxide. The first measurable effects on iridium, aluminum, nickel, tungsten and niobium thin films are reported.

  2. SMALL ANGLE SCATTERING OF X-RAYS BY PLASTICALLY DEFORMED SINGLE CRYSTALS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Robinson, W.H.; Smoluchowski, R.

    1959-05-01

    The small-angle scattering of x rays from single crystals of magnesium plastically deformed by simple shear was measured in the angular range of 4' to 5 deg . The crystals were subjected to both unidirectional and cyclic shear stresses applied along the STAl 1 2-bar 0! direction. Thin slices of the deformed single crystals were prepared using strainfree cutting and polishing techniques. The thin slices had orientations such that the slip direction was either parallel or perpendicular to the incident x-ray beam in order to observe any anisotropy in the scattering that might be due to dislocations. It was foundmore » that those samples which contained deformation twins within the irradiated volume produced rather large scattered intensity. This scattered intensity is interpreted as being due to double Bragg scattering. The scattered intensity from other specimens was attributed to surface scattering. No evidence for small angle scattering by dislocations was found. (auth)« less

  3. 25 CFR 301.8 - Finish.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 25 Indians 2 2010-04-01 2010-04-01 false Finish. 301.8 Section 301.8 Indians INDIAN ARTS AND CRAFTS BOARD, DEPARTMENT OF THE INTERIOR NAVAJO, PUEBLO, AND HOPI SILVER AND TURQUOISE PRODUCTS; STANDARDS § 301.8 Finish. All silver is to be hand polished. ...

  4. Prevalence of burnout in Polish anesthesiologists and anesthetist nursing professionals: A comparative non-randomized cross-sectional study.

    PubMed

    Misiołek, Aleksandra; Gil-Monte, Pedro R; Misiołek, Hanna

    2017-03-01

    The purpose of the study was to assess the burnout levels in nurses ( N = 161) versus physicians ( N = 373). The levels of burnout were evaluated by the Polish adaptation of the Spanish Burnout Inventory (Cronbach's alpha > .70). High burnout level was found in 18.63 percent nurses and 12.06 percent anesthesiologists, and critical level in 3.74 percent nurses and 5.90 percent anesthetists. There were statistically significant differences in Burnout global score, Enthusiasm toward the job, Psychological exhaustion, and Indolence subscales between nurses and physicians. No significant differences were found between sexes in any variable.

  5. Estimating pore and cement volumes in thin section

    USGS Publications Warehouse

    Halley, R.B.

    1978-01-01

    Point count estimates of pore, grain and cement volumes from thin sections are inaccurate, often by more than 100 percent, even though they may be surprisingly precise (reproducibility + or - 3 percent). Errors are produced by: 1) inclusion of submicroscopic pore space within solid volume and 2) edge effects caused by grain curvature within a 30-micron thick thin section. Submicroscopic porosity may be measured by various physical tests or may be visually estimated from scanning electron micrographs. Edge error takes the form of an envelope around grains and increases with decreasing grain size and sorting, increasing grain irregularity and tighter grain packing. Cements are greatly involved in edge error because of their position at grain peripheries and their generally small grain size. Edge error is minimized by methods which reduce the thickness of the sample viewed during point counting. Methods which effectively reduce thickness include use of ultra-thin thin sections or acetate peels, point counting in reflected light, or carefully focusing and counting on the upper surface of the thin section.

  6. Implementation of new integrated evaporation equipment for the preparation of 238U targets and improvement of the deposition process

    NASA Astrophysics Data System (ADS)

    Vanleeuw, D.; Lewis, D.; Moens, A.; Sibbens, G.; Wiss, T.

    2018-05-01

    Measurement of neutron cross section data is a core activity of the JRC-Directorate G for Nuclear Safety and Security in Geel. After a period of reduced activity and in line with a renewed interest for nuclear data required for GenIV reactors and waste minimization, the demand for high quality actinide targets increased. Physical vapour deposition by thermal evaporation is a key technique to prepare homogeneous thin actinide layers, but due to ageing effects the earlier in-house developed equipment can no longer provide the required quality. Because of a current lack of experience and human resources cooperation with private companies is required for the development of new deposition equipment directly integrated in a glove box. In this paper we describe the design, implementation and validation of the first commercial actinide evaporator in a glove box as well as the optimization of the deposition process. Highly enriched 238U3O8 was converted to 238UF4 powder and several deposition runs were performed on different substrates. The deposition parameters were varied and defined in order to guarantee physical and chemical stable homogeneous UF4 layers, even on polished substrates which was not longer feasible with the older equipment. The stability problem is discussed in view of the thin layer growth by physical vapour deposition and the influence of the deposition parameters on the layer quality. The deposits were characterized for the total mass by means of substitution weighing and for the areal density of 238U by means of alpha particle counting and thermal ionization mass spectrometry (TIMS). The quality of the layer was visually evaluated and by means of stereo microscopy and auto radiography.

  7. Properties of AlF3 and LaF3 films at 193nm

    NASA Astrophysics Data System (ADS)

    Xue, Chunrong; Shao, Jianda

    2010-10-01

    In order to develop low loss, high-performance 193nm Fluoride HR mirrors and anti-reflection coatings, LaF3 and AlF3 materials, used for a single-layer coating, were deposited by a molybdenum boat evaporation process. Various microstructures that formed under different substrate temperatures and with deposition rates were investigated. The relation between these microstructures (including cross section morphology, surface roughness and crystalline structure), the optical properties (including refractive index and optical loss) and mechanical properties (stress) were investigated. Furthermore, AlF3 used as a low-index material and LaF3 used as a high-index material were designed and deposited for multilayer coatings. Transmittance, reflectance, stress, and the laser-induced damage threshold (LIDT) were studied. It is shown that AlF3 and LaF3 thin films, deposited on the substrate at a temperature of 300 °C, obtained good quality thin films with high transmittance and little optical loss at 193 nm. For multilayer coatings, the absorption mainly comes from LaF3. Based on these studies, The thickness of 193nm films was controled by a 1/3 baffle with pre-coating technology. the LaF3/AlF3 AR coantings and HR mirrors at 193nm were designed and deposited. Under the present experimental conditions, the reflectance of LaF3/AlF3 HR mirror is up to 96%, and its transmittance is 1.5%. the LaF3/AlF3 AR coanting's residual reflectance is less than 0.14%, and single-sided transmittance is 93.85%. To get a high-performance 193nm AR coating, super-polished substrate is the best choice.

  8. An evaluation of the effects of handpiece speed, abrasive characteristics, and polishing load on the flexural strength of polished ceramics.

    PubMed

    Ahmad, Rohana; Morgano, Steven M; Wu, Benjamin M; Giordano, Russell A

    2005-11-01

    Many studies on the strengthening effects of grinding and polishing, as well as heat treatment on ceramics, are not well standardized or use commercially available industrial polishing systems. The reported effectiveness of these strengthening mechanisms on ceramics may not be applicable to clinical dentistry. The purpose of this study was to evaluate the effects of controlled polishing on the flexural strength of dental ceramics by using a custom-made machine that applied standardized loads and speeds that coincided with the mean loads and speeds used by experienced prosthodontists. A total of 140 aluminous dental ceramic bar-shaped specimens (Vitadur Alpha Enamel) measuring 1.5 x 2.0 x 25 mm were fabricated and divided into 12 groups (for most groups, n=10). Specimens were untreated, polished with different polishing systems, polished at different speeds, ground and autoglazed, polished and autoglazed, autoglazed and polished, polished with loose (paste) and bonded abrasives, or overglazed. Simulated clinical polishing was performed on the ceramic specimens by using a customized polishing apparatus that allowed independent control over the relevant polishing parameters (abrasive hardness, applied load, linear speed, rotational velocity, and wheel stiffness). Flexural strength (MPa) was measured with a 4-point bending test, and subjective surface roughness was assessed with scanning electron microscopy. Autoglazing was performed at various stages of the polishing sequence to determine the effects of polishing on surface stresses. Mean values, standard deviations, independent-sample t tests, 1-way and 2-way analyses of variance, Dunnett t tests and Kruskal-Wallis tests were applied to the data (alpha=.05). Under a clinical load of 0.6 N for a coarse polishing wheel, 1.0 N for a medium polishing wheel, and 1.3 N for a fine polishing wheel, a linear speed of 499 mm/min, and a rotational velocity of 10,000 rpm, the use of clinical polishing instruments did not affect the flexural strength of the aluminous ceramics studied (P=.274). At higher rotational velocity (20,000 rpm), specimens polished with the diamond polishing system produced statistically weaker specimens compared with those that had been polished at 10,000 rpm (P=.019). Autoglazing treatment of the diamond-polished specimens did not reverse the strength degradation (P=.125). Conversely, diamond polishing of the autoglazed specimens resulted in significant flexural strength reduction (P=.029). Fine-diamond-bonded abrasive significantly reduced flexural strength (P=.025). Simulated clinical polishing at 10,000 rpm did not appear to substantially strengthen or weaken the ceramic specimens. Polishing at 20,000 rpm reduced flexural strength of the ceramic bars.

  9. Prediction of a nail polish colour applied on a nail.

    PubMed

    Monpeurt, C; Cinotti, E; Razafindrakoto, J; Rubegni, P; Fimiani, M; Perrot, J L; Hebert, M

    2018-02-01

    The colour of a nail polish varies according to the nail on which it is applied. The objective of this study was to predict the colour of the nail polish on a given nail and to study how the colour varies depending on the nail polish thickness. Six nail polishes were applied in one, two and three layers on the nails of one subject, thus forming eighteen samples. The spectral reflectances of the eighteen nail polishes applied on the nails with different thicknesses were obtained by spectrophotometry. The spectral reflectances of the nails without polish were also measured using the same technique. The thicknesses of nail polishes were measured by high-definition optical coherence tomography (HD-OCT). Then, to determine the physical parameters of the nail polish itself, we applied the six nail polishes on an opacity drawdown chart and we measured the spectral reflectance and the thickness of each patch using spectrophotometry and HD-OCT, respectively. The Kubelka-Munk theory was used to get the predicted spectral reflectance of the nail polish applied on the nail according to the polish thickness by knowing the parameter of the polish itself and the spectral reflectance of the nail. The predicted spectral reflectances were finally compared with those measured directly on the nails. The predicted spectral reflectances were rather close to measured ones. Consequently, knowing the colour of the nail without polish and the optical parameters of the nail polish itself, we can estimate the colour of the nail polish applied on the nail depending on its thickness. Our study showed that the Kubelka-Munk theory can be used to predict the nail polish colour. The ability to predict the real colour of a nail polish applied on a nail could help a nail polish manufacturer to improve his polish formulae in order to obtain a precise colour. © 2017 Society of Cosmetic Scientists and the Société Française de Cosmétologie.

  10. An In-situ Real-Time Optical Fiber Sensor Based on Surface Plasmon Resonance for Monitoring the Growth of TiO2 Thin Films

    PubMed Central

    Tsao, Yu-Chia; Tsai, Woo-Hu; Shih, Wen-Ching; Wu, Mu-Shiang

    2013-01-01

    An optical fiber sensor based on surface plasmon resonance (SPR) is proposed for monitoring the thickness of deposited nano-thin films. A side-polished multimode SPR optical fiber sensor with an 850 nm-LD is used as the transducing element for real-time monitoring of the deposited TiO2 thin films. The SPR optical fiber sensor was installed in the TiO2 sputtering system in order to measure the thickness of the deposited sample during TiO2 deposition. The SPR response declined in real-time in relation to the growth of the thickness of the TiO2 thin film. Our results show the same trend of the SPR response in real-time and in spectra taken before and after deposition. The SPR transmitted intensity changes by approximately 18.76% corresponding to 50 nm of deposited TiO2 thin film. We have shown that optical fiber sensors utilizing SPR have the potential for real-time monitoring of the SPR technology of nanometer film thickness. The compact size of the SPR fiber sensor enables it to be positioned inside the deposition chamber, and it could thus measure the film thickness directly in real-time. This technology also has potential application for monitoring the deposition of other materials. Moreover, in-situ real-time SPR optical fiber sensor technology is in inexpensive, disposable technique that has anti-interference properties, and the potential to enable on-line monitoring and monitoring of organic coatings. PMID:23881144

  11. An in-situ real-time optical fiber sensor based on surface plasmon resonance for monitoring the growth of TiO2 thin films.

    PubMed

    Tsao, Yu-Chia; Tsai, Woo-Hu; Shih, Wen-Ching; Wu, Mu-Shiang

    2013-07-23

    An optical fiber sensor based on surface plasmon resonance (SPR) is proposed for monitoring the thickness of deposited nano-thin films. A side-polished multimode SPR optical fiber sensor with an 850 nm-LD is used as the transducing element for real-time monitoring of the deposited TiO2 thin films. The SPR optical fiber sensor was installed in the TiO2 sputtering system in order to measure the thickness of the deposited sample during TiO2 deposition. The SPR response declined in real-time in relation to the growth of the thickness of the TiO2 thin film. Our results show the same trend of the SPR response in real-time and in spectra taken before and after deposition. The SPR transmitted intensity changes by approximately 18.76% corresponding to 50 nm of deposited TiO2 thin film. We have shown that optical fiber sensors utilizing SPR have the potential for real-time monitoring of the SPR technology of nanometer film thickness. The compact size of the SPR fiber sensor enables it to be positioned inside the deposition chamber, and it could thus measure the film thickness directly in real-time. This technology also has potential application for monitoring the deposition of other materials. Moreover, in-situ real-time SPR optical fiber sensor technology is in inexpensive, disposable technique that has anti-interference properties, and the potential to enable on-line monitoring and monitoring of organic coatings.

  12. Semi-thin sections of epoxy resin-embedded mouse embryos in morphological analysis of whole mount in situ RNA hybridization.

    PubMed

    Mitrecić, D; Cunko, V F; Gajović, S

    2008-12-01

    Descriptive morphological studies are often combined with gene expression pattern analyses. Unembedded vibratome or cryotome sections are compatible with in situ RNA hybridization, but spatial resolution is rather low for precise microscopic studies necessary in embryology. Therefore, use of plastic embedding media, which allow semi-thin and ultra-thin sectioning for light and electron microscopy, could be an important advantage. This work suggested a new approach based on the whole mount hybridization of mouse embryos and subsequent epoxy resin embedding. Epoxy resin allowed serial sectioning of semi-thin sections with preserved in situ RNA hybridization signal, which was a necessary prerequisite for precise morphological analysis of embryo development.

  13. 8 CFR 1245.12 - What are the procedures for certain Polish and Hungarian parolees who are adjusting status to...

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... Immigration Reform and Immigrant Responsibility Act of 1996? 1245.12 Section 1245.12 Aliens and Nationality... Immigration Reform and Immigrant Responsibility Act of 1996? (a) How do I apply for adjustment of status under...

  14. Meningococcal Infections - Multiple Languages

    MedlinePlus

    ... Pohnpeian (Mahsen en Pohnpei) Polish (polski) Portuguese (português) Punjabi (ਪੰਜਾਬੀ) Russian (Русский) Samoan (Gagana Samoa) Somali ( ... Portuguese) PDF Centers for Disease Control and Prevention Punjabi (ਪੰਜਾਬੀ) Expand Section Vaccine Information Statement (VIS) -- ...

  15. Meningitis - Multiple Languages

    MedlinePlus

    ... Pohnpeian (Mahsen en Pohnpei) Polish (polski) Portuguese (português) Punjabi (ਪੰਜਾਬੀ) Russian (Русский) Samoan (Gagana Samoa) Somali ( ... Portuguese) PDF Centers for Disease Control and Prevention Punjabi (ਪੰਜਾਬੀ) Expand Section Vaccine Information Statement (VIS) -- ...

  16. Genesis of Augite-Bearing Ureilites: Evidence From LA-ICP-MS Analyses of Pyroxenes and Olivine

    NASA Technical Reports Server (NTRS)

    Herrin, J. S.; Lee, C-T. A.; Mittlefehldt, D. W.

    2008-01-01

    Ureilites are ultramafic achondrites composed primarily of coarse-grained low-Ca pyroxene and olivine with interstitial carbonaceous material, but a number of them contain augite [1]. Ureilites are considered to be restites after partial melting of a chondritic precursor, although at least some augite-bearing ureilites may be partially cumulate [1, 2]. In this scenario, the augite is a cumulus phase derived from a melt that infiltrated a restite composed of typical ureilite material (olivine+low-Ca pyroxene) [2]. To test this hypothesis, we examined the major and trace element compositions of silicate minerals in select augite-bearing ureilites with differing mg#. Polished thick sections of the augite-bearing ureilites ALH 84136 , EET 87511, EET 96293, LEW 88201, and META78008 and augite-free typical ureilite EET 90019 were examined by EPMA for major and minor elements and laser ablation ICP-MS (LA-ICP-MS) for trace elements, REE in particular. Although EET 87511 is reported to contain augite, the polished section that we obtained did not.

  17. A contribution to the characterization of the silicate-water interface - Part I: Implication of a new polished sample hydration technique.

    PubMed

    Sowoidnich, T; Gordon, L; Naber, C; Bellmann, F; Neubauer, J; Joester, D

    2018-06-11

    The analysis of the atomic composition of the interface between tricalcium silicate (C 3 S), the main compound of Ordinary Portland Cement, and surrounding solution is still a challenging task. At the same time, that knowledge is of profound importance for describing the basic processes during hydration. By means of Scanning Electron Microscopy (SEM) and Atom Probe Tomography (APT) we combine modern techniques in order to shed light on this topic in the present study. The results of these methods are compared with conduction calorimetry as a standard technique to study the hydration kinetics of cement. The tests were carried out on powders as well as on polished C 3 S samples. Results indicate that the progress of hydration is strongly increased when the C 3 S is used in the form of polished specimen. First C-S-H phases are detected in the powder 2.2 h after contact with water, on the polished section after 5 min. Besides SEM, the formation of C-S-H phases can be detected by APT, leading to an advantageous atomic resolution compared to EDX analysis. We propose that the use of APT will lead to deeper insights on the hydration progress and on the composition of the sensitive C-S-H phases based on these first results. Copyright © 2018 Elsevier Ltd. All rights reserved.

  18. PROBLEMS OF THE OPTICAL MODEL FOR DEUTERONS. II. EXPERIMENTS FOR DETERMINATION OF THE PARAMETERS OF THE OPTICAL POTENTIAL FOR DEUTERONS (in Polish)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Grotowski, K.

    1963-01-01

    An experiment for determination of the parameters of the optical potential for deuterons is presented. Total reaction cross sections for the interaction of deuterons with nuclei were determined by evaluating the cross sections for the emission of charged particles and neutrons. The angular distributions for the elastic scattering of deuterons were also measured. (auth)

  19. Attack polish for nickel-base alloys and stainless steels

    DOEpatents

    Steeves, Arthur F.; Buono, Donald P.

    1983-01-01

    A chemical attack polish and polishing procedure for use on metal surfaces such as nickel base alloys and stainless steels. The chemical attack polish comprises Fe(NO.sub.3).sub.3, concentrated CH.sub.3 COOH, concentrated H.sub.2 SO.sub.4 and H.sub.2 O. The polishing procedure includes saturating a polishing cloth with the chemical attack polish and submicron abrasive particles and buffing the metal surface.

  20. Method of polishing nickel-base alloys and stainless steels

    DOEpatents

    Steeves, Arthur F.; Buono, Donald P.

    1981-01-01

    A chemical attack polish and polishing procedure for use on metal surfaces such as nickel base alloys and stainless steels. The chemical attack polish comprises Fe(NO.sub.3).sub.3, concentrated CH.sub.3 COOH, concentrated H.sub.2 SO.sub.4 and H.sub.2 O. The polishing procedure includes saturating a polishing cloth with the chemical attack polish and submicron abrasive particles and buffing the metal surface.

  1. Ion-damage-free planarization or shallow angle sectioning of solar cells for mapping grain orientation and nanoscale photovoltaic properties

    DOE PAGES

    Kutes, Yasemin; Luria, Justin; Sun, Yu; ...

    2017-04-11

    Ion beam milling is the most common modern method for preparing specific features for microscopic analysis, even though concomitant ion implantation and amorphization remain persistent challenges, particularly as they often modify materials properties of interest. Atomic force microscopy (AFM), on the other hand, can mechanically mill specific nanoscale regions in plan-view without chemical or high energy ion damage, due to its resolution, directionality, and fine load control. As an example, AFM-nanomilling (AFM-NM) is implemented for top-down planarization of polycrystalline CdTe thin film solar cells, with a resulting decrease in the root mean square (RMS) roughness by an order of magnitude,more » even better than for a low incidence FIB polished surface. Subsequently AFM-based property maps reveal a substantially stronger contrast, in this case of the short-circuit current or open circuit voltage during light exposure. Furthermore, electron back scattering diffraction (EBSD) imaging also becomes possible upon AFM-NM, enabling direct correlations between the local materials properties and the polycrystalline microstructure. Smooth shallow-angle cross-sections are demonstrated as well, based on targeted oblique milling. As expected, this reveals a gradual decrease in the average short-circuit current and maximum power as the underlying CdS and electrode layers are approached, but a relatively consistent open-circuit voltage through the diminishing thickness of the CdTe absorber. AFM-based nanomilling is therefore a powerful tool for material characterization, uniquely providing ion-damage free, selective area, planar smoothing or low-angle sectioning of specimens while preserving their functionality. This then enables novel, co-located advanced AFM measurements, EBSD analysis, and investigations by related techniques that are otherwise hindered by surface morphology or surface damage.« less

  2. Ion-damage-free planarization or shallow angle sectioning of solar cells for mapping grain orientation and nanoscale photovoltaic properties

    NASA Astrophysics Data System (ADS)

    Kutes, Yasemin; Luria, Justin; Sun, Yu; Moore, Andrew; Aguirre, Brandon A.; Cruz-Campa, Jose L.; Aindow, Mark; Zubia, David; Huey, Bryan D.

    2017-05-01

    Ion beam milling is the most common modern method for preparing specific features for microscopic analysis, even though concomitant ion implantation and amorphization remain persistent challenges, particularly as they often modify materials properties of interest. Atomic force microscopy (AFM), on the other hand, can mechanically mill specific nanoscale regions in plan-view without chemical or high energy ion damage, due to its resolution, directionality, and fine load control. As an example, AFM-nanomilling (AFM-NM) is implemented for top-down planarization of polycrystalline CdTe thin film solar cells, with a resulting decrease in the root mean square (RMS) roughness by an order of magnitude, even better than for a low incidence FIB polished surface. Subsequent AFM-based property maps reveal a substantially stronger contrast, in this case of the short-circuit current or open circuit voltage during light exposure. Electron back scattering diffraction (EBSD) imaging also becomes possible upon AFM-NM, enabling direct correlations between the local materials properties and the polycrystalline microstructure. Smooth shallow-angle cross-sections are demonstrated as well, based on targeted oblique milling. As expected, this reveals a gradual decrease in the average short-circuit current and maximum power as the underlying CdS and electrode layers are approached, but a relatively consistent open-circuit voltage through the diminishing thickness of the CdTe absorber. AFM-based nanomilling is therefore a powerful tool for material characterization, uniquely providing ion-damage free, selective area, planar smoothing or low-angle sectioning of specimens while preserving their functionality. This enables novel, co-located advanced AFM measurements, EBSD analysis, and investigations by related techniques that are otherwise hindered by surface morphology or surface damage.

  3. Phosphate microaggregates in Archean sediments. [Abstract only

    NASA Technical Reports Server (NTRS)

    Mojzsis, S.; Fan, G. Y.; Arrhenius, G.

    1994-01-01

    Light microscopy conducted on samples of Archean sediments reveals phosphate microaggregates which are suggestive of a biotic origin (Arrhenius et al., 1993). These aggregates, typically 15 micrometers wide and 50 micrometers long, are thought to be the mineral remains of colonies of microorganisms that lived during the late Archean Eon (greater than or equal to 2.5 Ga). Confocal microscopy was used to study the structures of these microaggregates in three dimensions. Samples used in this study are from the lowermost section of drill core taken from the Dales Gorge Member of the Brockman Iron-Formation (Hamersley Basin) in Western Australia. These sediments are well-preserved and escaped extensive metamorphism typically experienced by older rocks of this type. Two types of samples were prepared for study under the microscope: thin sections (30 micrometers) for transmitted light microscopy to study the general rock texture and to locate the grains of interest, and thick sections (3mm) for confocal microscopy to determine the 3-D structure of the aggregates in situ. The samples have been carefully polished so that they may be directly placed on the oil-immersion lens without the use of a cover slip. No chemical treatments of the surfaces have been performed. The aggregates often form clusters, although isolated aggregates have also been found. The clusters tend to distribute along microbands in the rocks. Electron microprobe analyses show that the phosphate grains and their inclusions, besides calcium and phosphorus, contain no major elements heavier than sodium. The proportions of calcium to phosphorus, the absence of stoichiometric amounts of other cations such as magnesium and iron, as well as optical properties suggest apatite as the mineral form.

  4. An in vitro method for rapid regeneration of a monopodial orchid hybrid Aranda Deborah using thin section culture.

    PubMed

    Lakshmanan, P; Loh, C S; Goh, C J

    1995-05-01

    A thin section culture system for rapid regeneration of the monopodial orchid hybrid Aranda Deborah has been developed. Thin sections (0.6-0.7mm thick) obtained by transverse sectioning of a single shoot tip (6-7mm), when cultured in Vacin and Went medium enriched with coconut water (20% v/v), produced an average 13.6 protocorm-like bodies (PLB) after 45 days, compared to 2.7 PLB formed by a single 6-7 mm long shoot tip under same culture condition. Addition of α-naphthaleneacetic acid to Vacin and Went medium enriched with coconut water further increased PLB production by thin sections. PLB developed into plantlets on solid Vacin and Went medium containing 10% (v/v) coconut water and 0.5 g l(-1) activated charcoal. With this procedure, more than 80,000 plantlets could be produced from thin sections obtained from a single shoot tip in a year as compared to nearly 11,000 plantlets produced by the conventional shoot tip method.

  5. Research on the magnetorheological finishing (MRF) technology with dual polishing heads

    NASA Astrophysics Data System (ADS)

    Huang, Wen; Zhang, Yunfei; He, Jianguo; Zheng, Yongcheng; Luo, Qing; Hou, Jing; Yuan, Zhigang

    2014-08-01

    Magnetorheological finishing (MRF) is a key polishing technique capable of rapidly converging to the required surface figure. Due to the deficiency of general one-polishing-head MRF technology, a dual polishing heads MRF technology was studied and a dual polishing heads MRF machine with 8 axes was developed. The machine has the ability to manufacture large aperture optics with high figure accuracy. The large polishing head is suitable for polishing large aperture optics, controlling large spatial length's wave structures, correcting low-medium frequency errors with high removal rates. While the small polishing head has more advantages in manufacturing small aperture optics, controlling small spatial wavelength's wave structures, correcting mid-high frequency and removing nanoscale materials. Material removal characteristic and figure correction ability for each of large and small polishing head was studied. Each of two polishing heads respectively acquired stable and valid polishing removal function and ultra-precision flat sample. After a single polishing iteration using small polishing head, the figure error in 45mm diameter of a 50 mm diameter plano optics was significantly improved from 0.21λ to 0.08λ by PV (RMS 0.053λ to 0.015λ). After three polishing iterations using large polishing head , the figure error in 410mm×410mm of a 430mm×430mm large plano optics was significantly improved from 0.40λ to 0.10λ by PV (RMS 0.068λ to 0.013λ) .This results show that the dual polishing heads MRF machine not only have good material removal stability, but also excellent figure correction capability.

  6. Ergonomic risk factors of work processes in the semiconductor industry in Peninsular Malaysia.

    PubMed

    Chee, Heng-Leng; Rampal, Krishna Gopal; Chandrasakaran, Abherhame

    2004-07-01

    A cross-sectional survey of semiconductor factories was conducted to identify the ergonomic risk factors in the work processes, the prevalence of body pain among workers, and the relationship between body pain and work processes. A total of 906 women semiconductor workers took part in the study. In wafer preparation and polishing, a combination of lifting weights and prolonged standing might have led to high pain prevalences in the low back (35.0% wafer preparation, 41.7% wafer polishing) and lower limbs (90.0% wafer preparation, 66.7% wafer polishing). Semiconductor front of line workers, who mostly walked around to operate machines in clean rooms, had the lowest prevalences of body pain. Semiconductor assembly middle of line workers, especially the molding workers, who did frequent lifting, had high pain prevalences in the neck/shoulders (54.8%) and upper back (43.5 %). In the semiconductor assembly end of line work section, chip inspection workers who were exposed to prolonged sitting without back support had high prevalences of neck/shoulder (62.2%) and upper back pain (50.0%), while chip testing workers who had to climb steps to load units had a high prevalence of lower limb pain (68.0%). Workers in the assembly of electronic components, carrying out repetitive tasks with hands and fingers, and standing in awkward postures had high pain prevalences in the neck/shoulders (61.5%), arms (38.5%), and hands/wrists (30.8%).

  7. Center removal amount control of magnetorheological finishing process by spiral polishing way

    NASA Astrophysics Data System (ADS)

    Wang, Yajun; He, Jianguo; Ji, Fang; Huang, Wen; Xiao, Hong; Luo, Qing; Zheng, Yongcheng

    2010-10-01

    Spiral polishing is a traditional process of computer-controlled optical surfacing. However, the additional polishing amount is great and the center polishing amount is difficult to control. At first, a simplified mathematics model is presented for magnetorheological finishing, which indicates that the center polishing amount and additional polishing amount are proportional to the length and peak value of magnetorheological finishing influence function, and are inversely proportional to pitch and rotation rate of spiral track, and the center polishing amount is much bigger than average polishing amount. Secondly, the relationships of "tool feed way and center polishing amount", "spiral pitch and calculation accuracy of influence matrix for dwell time function solution", "spiral pitch and center polishing amount" and "peak removal rate, dimensions of removal function and center removal amount" are studied by numerical computation by Archimedes spiral path. It shows that the center polishing amount is much bigger in feed stage than that in backhaul stage when the head of influence function is towards workpiece edge in feeding; and the bigger pitch, the bigger calculation error of influence matrix elements; and the bigger pitch, the smaller center polishing amount, and the smaller peak removal rate and dimensions of removal function, the smaller center removal amount. At last, the polishing results are given, which indicates that the center polishing amount is acceptable with a suitable polishing amount rate of feed stage and backhaul stage, and with a suitable spiral pitch during magnetorheological finishing procedure by spiral motion way.

  8. The study of optimization on process parameters of high-accuracy computerized numerical control polishing

    NASA Astrophysics Data System (ADS)

    Huang, Wei-Ren; Huang, Shih-Pu; Tsai, Tsung-Yueh; Lin, Yi-Jyun; Yu, Zong-Ru; Kuo, Ching-Hsiang; Hsu, Wei-Yao; Young, Hong-Tsu

    2017-09-01

    Spherical lenses lead to forming spherical aberration and reduced optical performance. Consequently, in practice optical system shall apply a combination of spherical lenses for aberration correction. Thus, the volume of the optical system increased. In modern optical systems, aspherical lenses have been widely used because of their high optical performance with less optical components. However, aspherical surfaces cannot be fabricated by traditional full aperture polishing process due to their varying curvature. Sub-aperture computer numerical control (CNC) polishing is adopted for aspherical surface fabrication in recent years. By using CNC polishing process, mid-spatial frequency (MSF) error is normally accompanied during this process. And the MSF surface texture of optics decreases the optical performance for high precision optical system, especially for short-wavelength applications. Based on a bonnet polishing CNC machine, this study focuses on the relationship between MSF surface texture and CNC polishing parameters, which include feed rate, head speed, track spacing and path direction. The power spectral density (PSD) analysis is used to judge the MSF level caused by those polishing parameters. The test results show that controlling the removal depth of single polishing path, through the feed rate, and without same direction polishing path for higher total removal depth can efficiently reduce the MSF error. To verify the optical polishing parameters, we divided a correction polishing process to several polishing runs with different direction polishing paths. Compare to one shot polishing run, multi-direction path polishing plan could produce better surface quality on the optics.

  9. Machining heavy plastic sections

    NASA Technical Reports Server (NTRS)

    Stalkup, O. M.

    1967-01-01

    Machining technique produces consistently satisfactory plane-parallel optical surfaces for pressure windows, made of plexiglass, required to support a photographic study of liquid rocket combustion processes. The surfaces are machined and polished to the required tolerances and show no degradation from stress relaxation over periods as long as 6 months.

  10. Lead Pipe Scale Analysis Using Broad-Beam Argon Ion Milling to Elucidate Drinking Water Corrosion

    EPA Science Inventory

    Herein, we compared the characterization of lead pipe scale removed from a drinking water distribution system using two different cross section methods (conventional polishing and argon ion beam etching). The pipe scale solids were analyzed using scanning electron microscopy (SEM...

  11. Colonoscopy - Multiple Languages

    MedlinePlus

    ... français) Haitian Creole (Kreyol ayisyen) Hindi (हिन्दी) Japanese (日本語) Korean (한국어) Polish (polski) Portuguese (português) Russian ( ... हिन्दी (Hindi) Bilingual PDF Health Information Translations Japanese (日本語) Expand Section Colonoscopy with Bowel Prep: Go- ...

  12. A comparative analysis of microscopic alterations in modern and ancient undecalcified and decalcified dry bones.

    PubMed

    Caruso, Valentina; Cummaudo, Marco; Maderna, Emanuela; Cappella, Annalisa; Caudullo, Giorgio; Scarpulla, Valentina; Cattaneo, Cristina

    2018-02-01

    The present study aims to evaluate the preservation of the microstructure of skeletal remains collected from four different known burial sites (archaeological and contemporary). Histological analysis on undecalcified and decalcified thin sections was performed in order to assess which of the two techniques is more affected by taphonomic insults. A histological analysis was performed on both undecalcified and decalcified thin sections of 40 long bones and the degree of diagenetic change was evaluated using transmitted and polarized light microscopy according to the Oxford Histological Index (OHI). In order to test the optical behavior of bone tissue, thin sections were observed by polarized light microscopy and the intensity of birefringence was evaluated. The more ancient samples are generally characterized by a low OHI (0-1) with extensive microscopic focal destruction; recent samples exhibited a better preservation of bone micromorphology. When comparing undecalcified to decalcified thin sections, the latter showed an amelioration in the conservation of microscopic structure. As regards the birefringence, it was very low in all the undecalcified thin sections, whereas decalcification process seems to improve its visibility. The preservation of the bone microscopic structure appears to be influenced not only by age, but also by the burial context. Undecalcified bones appear to be more affected by taphonomical alterations, probably because of the thickness of the thin sections; on the contrary, decalcified thin sections proved to be able to tackle this issue allowing a better reading of the bone tissue. © 2017 Wiley Periodicals, Inc.

  13. Cement line staining in undecalcified thin sections of cortical bone

    NASA Technical Reports Server (NTRS)

    Bain, S. D.; Impeduglia, T. M.; Rubin, C. T.

    1990-01-01

    A technique for demonstrating cement lines in thin, undecalcified, transverse sections of cortical bone has been developed. Cortical bone samples are processed and embedded undecalcified in methyl methacrylate plastic. After sectioning at 3-5 microns, cross-sections are transferred to a glass slide and flattened for 10 min. Sections of cortical bone are stained for 20 sec free-floating in a fresh solution of 1% toluidine blue dissolved in 0.1% formic acid. The section is dehydrated in t-butyl alcohol, cleared in xylene, and mounted with Eukitt's medium. Reversal lines appear as thin, scalloped, dark blue lines against a light blue matrix, whereas bone formation arrest lines are thicker with a smooth contour. With this technique cellular detail, osteoid differentiation, and fluorochrome labels are retained. Results demonstrate the applicability of a one-step staining method for cement lines which will facilitate the assessment of bone remodeling activity in thin sections of undecalcified cortical bone.

  14. A thermal microprobe fabricated with wafer-stage processing

    NASA Astrophysics Data System (ADS)

    Zhang, Yongxia; Zhang, Yanwei; Blaser, Juliana; Sriram, T. S.; Enver, Ahsan; Marcus, R. B.

    1998-05-01

    A thermal microprobe has been designed and built for high resolution temperature sensing. The thermal sensor is a thin-film thermocouple junction at the tip of an atomic force microprobe (AFM) silicon probe needle. Only wafer-stage processing steps are used for the fabrication. For high resolution temperature sensing it is essential that the junction be confined to a short distance at the AFM tip. This confinement is achieved by a controlled photoresist coating process. Experiment prototypes have been made with an Au/Pd junction confined to within 0.5 μm of the tip, with the two metals separated elsewhere by a thin insulating oxide layer. Processing begins with double-polished, n-type, 4 in. diameter, 300-μm-thick silicon wafers. Atomically sharp probe tips are formed by a combination of dry and wet chemical etching, and oxidation sharpening. The metal layers are sputtering deposited and the cantilevers are released by a combination of KOH and dry etching. A resistively heated calibration device was made for temperature calibration of the thermal microprobe over the temperature range 25-110 °C. Over this range the thermal outputs of two microprobes are 4.5 and 5.6 μV/K and is linear. Thermal and topographical images are also obtained from a heated tungsten thin film fuse.

  15. The numerical model of multi-layer insulation with a defined wrapping pattern immersed in superfluid helium

    NASA Astrophysics Data System (ADS)

    Malecha, Ziemowit; Lubryka, Eliza

    2017-11-01

    The numerical model of thin layers, characterized by a defined wrapping pattern can be a crucial element of many computational problems related to engineering and science. A motivating example is found in multilayer electrical insulation, which is an important component of superconducting magnets and other cryogenic installations. The wrapping pattern of the insulation can significantly affect heat transport and the performance of the considered instruments. The major objective of this study is to develop the numerical boundary conditions (BC) needed to model the wrapping pattern of thin insulation. An example of the practical application of the proposed BC includes the heat transfer of Rutherford NbTi cables immersed in super-fluid helium (He II) across thin layers of electrical insulation. The proposed BC and a mathematical model of heat transfer in He II are implemented in the open source CFD toolbox OpenFOAM. The implemented mathematical model and the BC are compared in the experiments. The study confirms that the thermal resistance of electrical insulation can be lowered by implementing the proper wrapping pattern. The proposed BC can be useful in the study of new patterns for wrapping schemes. The work has been supported by statutory funds from Polish Ministry for Science and Higher Education for the year of 2017.

  16. [A study of different polishing techniques for amalgams and glass-cermet cement by scanning electron microscope (SEM)].

    PubMed

    Kakaboura, A; Vougiouklakis, G; Argiri, G

    1989-01-01

    Finishing and polishing an amalgam restoration, is considered as an important and necessary step of the restorative procedure. Various polishing techniques have been recommended to success a smooth amalgam surface. The aim of this study was to investigate the influence of three different polishing treatments on the marginal integrity and surface smoothness of restorations made of three commercially available amalgams and a glass-cermet cement. The materials used were the amalgams, Amalcap (Vivadent), Dispersalloy (Johnson and Johnson), Duralloy (Degussa) and the glass-cermet Katac-Silver (ESPE). The occlusal surfaces of the restorations were polished by the methods: I) round bur, No4-rubber cup-zinc oxide paste in a small brush, II) round bur No 4-bur-brown, green and super green (Shofu) polishing cups and points successively and III) amalgam polishing bur of 12-blades-smooth amalgam polishing bur. Photographs from unpolished and polished surfaces of the restorations, were taken with scanning electron microscope, to evaluate the polishing techniques. An improvement of marginal integrity and surface smoothness of all amalgam restorations was observed after the specimens had been polished with the three techniques. Method II, included Shofu polishers, proved the best results in comparison to the methods I and III. Polishing of glass-cermet cement was impossible with the examined techniques.

  17. Fine-scale structure and micromorphology of the Cricket Flat paleosol, Elgin, Oregon, USA

    NASA Astrophysics Data System (ADS)

    Murray, K.; Bader, N.

    2013-12-01

    The Cricket Flat paleosol is located about 9 km east of Elgin, Oregon on Oregon Route 82. The paleosol underlies an olivine basalt of the Powder River Volcanic Field, a sequence of Middle Miocene to Pliocene lavas that overlie the Columbia River Basalt Group in northeastern Oregon. The parent material of the paleosol is a felsic to intermediate lahar that contains leaf and twig fossils as well as tree casts. While some researchers have measured the bulk chemistry and clay mineralogy of this paleosol, no study of its micromorphology has been attempted. In this study we viewed polished thin sections with a petrographic microscope to examine both the parent material and the paleosol. Scanning electron microscopy was used to understand the composition of minerals. Soil texture was analyzed using point counts. Skeleton grains inherited from the parent are mainly plagioclase, orthoclase feldspar, quartz, and volcanic glass. Accessory minerals include titanite, epidote, apatite, and zircon. The paleosol has an argillic horizon with vertic features that are not apparent at the field scale. Diatoms, palynomorphs, and root traces are relatively common in the A horizon of the paleosol. Strong sepic plasmic fabrics and redoximorphic features suggest an environment that was at least seasonally waterlogged and subjected to shrink-swell processes.

  18. 25 CFR 301.7 - Stonecutting.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 25 Indians 2 2010-04-01 2010-04-01 false Stonecutting. 301.7 Section 301.7 Indians INDIAN ARTS AND CRAFTS BOARD, DEPARTMENT OF THE INTERIOR NAVAJO, PUEBLO, AND HOPI SILVER AND TURQUOISE PRODUCTS; STANDARDS § 301.7 Stonecutting. All stone used, including turquoise, is to be hand-cut and polished. This...

  19. Libraries for the Blind Section. Libraries Serving the General Public Division. Papers.

    ERIC Educational Resources Information Center

    International Federation of Library Associations, The Hague (Netherlands).

    Papers on library services and developments in reading materials for the blind, which were presented at the 1983 International Federation of Library Associations (IFLA) conference, include: (1) "Reading Programs for the Blind and Physically Handicapped in Public Libraries of the Polish People's Republic" by Franciszek Czajkowski…

  20. Cervical Cancer Screening - Multiple Languages

    MedlinePlus

    ... français) Haitian Creole (Kreyol ayisyen) Hindi (हिन्दी) Japanese (日本語) Korean (한국어) Polish (polski) Portuguese (português) Russian ( ... Screening - हिन्दी (Hindi) PDF American Cancer Society Japanese (日本語) Expand Section Colposcopy - 日本語 (Japanese) Bilingual PDF ...

  1. Flu Shot - Multiple Languages

    MedlinePlus

    ... Oromoo) Pashto (Pax̌tō / پښتو ) Polish (polski) Portuguese (português) Punjabi (ਪੰਜਾਬੀ) Russian (Русский) Somali (Af-Soomaali ) Spanish ( ... Portuguese) PDF Centers for Disease Control and Prevention Punjabi (ਪੰਜਾਬੀ) Expand Section Vaccine Information Statement (VIS) -- ...

  2. Sub-micron Raman Mapping of Ultramafic Fault Rock Textures

    NASA Astrophysics Data System (ADS)

    Tarling, M. S.; Rooney, J. S.; Smith, S. A. F.; Gordon, K. C.

    2016-12-01

    Deciphering the often complex temporal and microstructural relationships between the serpentine group minerals - antigorite, chrysotile, lizardite and polygonal serpentine - is essential for a proper understanding of the serpentinization process in a range of geodynamic settings. Conventional techniques such as optical microscopy, quantitative XRD and SEM-EDS often fail to correctly identify the four varieties of serpentine. Transmission electron microscopy can be used to successfully identify these minerals, but complex sample preparation and very small sample sizes (1-10's microns) means that microstructural context is difficult to maintain. Building on previous work (Petriglieri et al. 2015, J. Raman Spectrosc.) that introduced a methodology for Raman mapping on thin sections, we present the initial results of large-area and high-resolution (at the optical limit) Raman mapping that allows us to unambiguously distinguish and contextualise the serpentine minerals within their microstructural context. Measurements were performed on flat, SYTON-polished petrographic thin sections using a Witec Raman microscope equipped with a piezoelectric nano-positioning x-y stage. With a laser wavelength of 532 nm and a 100x dry objective, spatial resolution approaching 360 nm, as predicted by the Abbe equation, can readily be achieved. Minerals are primarily discerned by examining the Raman peaks in the high wavenumber spectral range of 3600-3710 cm-1, corresponding to OH-stretching vibrations. To illustrate the technique, Raman maps were acquired on several samples from the Livingstone Fault, a major terrane boundary in New Zealand that is localized in a mélange of ultramafic rocks including harzburgite and serpentinite. The maps highlight fine-scale intergrowths of antigorite, lizardite, chrysotile and related minerals (e.g. brucite, magnetite) at a sub-micron level over large areas (10's of microns to mm scale), features that are inaccessible or not visible using other techniques. In addition, the high-resolution mapping of discrete magnetite-bearing serpentinite slip surfaces has revealed the presence of 10-50 μm patches of nano-crystalline forsterite and enstatite, which may be the result of localized, faulting-induced, serpentinite dehydration.

  3. Metallic alternative to glass mirrors (active mirrors in aluminium) - A review

    NASA Astrophysics Data System (ADS)

    Rozelot, Jean P.; Leblanc, Jean-M.

    1991-09-01

    Present-day glass mirrors for telescopes, including the most recent results obtained with aluminum mirrors developed within the European EUREKA procedure (LAMA program) are reviewed. The major advantages of the aluminum-alloy solution, which can be extrapolated today for large size, are discussed. It is shown that aluminum-alloy meniscus blanks, polished on a thin nickel coating, are appropriate to manufacture mirrors of astronomical quality. With the technique of electron-beam welding, large sizes can be envisaged. The development of active optics makes it possible to easily compensate for real-time deformations. The good thermal diffusivity of aluminum alloys leads to a better and faster thermal equilibrium than all other glass structures.

  4. A measurement of the angular distribution of 5 eV atomic oxygen scattered off a solid surface in earth orbit

    NASA Technical Reports Server (NTRS)

    Gregory, John C.; Peters, Palmer N.

    1986-01-01

    The angular distribution of 5 eV atomic oxygen scattered off a polished vitreous carbon surface was measured on a recent Space Shuttle flight. The experimental apparatus was of novel design, completely passive, and used thin silver films as the recording device for oxygen atoms. Most of the incident oxygen was contained in the reflected beam and remained in an active form and probably still atoms. Allowance was made for 12 percent loss of incident atoms which are converted to CO at the carbon surface. The scattered distribution which is wide lobular, peaking 15 deg in the forward direction, shows almost but not quite full accommodation.

  5. Optical polarimetry: Instrumentation and applications; Proceedings of the Seminar, San Diego, Calif., August 23, 24, 1977

    NASA Technical Reports Server (NTRS)

    Azzam, R. M. A. (Editor); Coffeen, D. L.

    1977-01-01

    Instrumentation used in optical polarimetry is discussed with reference to high-resolution spectropolarimetry, an orbiter cloud photopolarimeter, X-ray polarimeters, and the design of a self-nulling ellipsometer. Consideration is given to surface and thin-film ellipsometry noting studies of electrochemical surface layers, surface anisotropy, polish layers on infrared window materials, and anodic films. Papers on biological, chemical, and physical polarimetry are presented including birefringence in biological materials, vibrational optical activity, and the optical determination of the thermodynamic phase diagram of a metamagnet. Remote sensing is discussed in terms of polarization imagery, the optical polarimetry of particulate surfaces, and techniques and applications of elliptical polarimetry in astronomy and atmospheric studies.

  6. Effect of Polishing Systems on Surface Roughness and Topography of Monolithic Zirconia.

    PubMed

    Goo, C L; Yap, Auj; Tan, Kbc; Fawzy, A S

    2016-01-01

    This study evaluated the effect of different chairside polishing systems on the surface roughness and topography of monolithic zirconia. Thirty-five monolithic zirconia specimens (Lava PLUS, 3M ESPE) were fabricated and divided into five groups of seven and polished with the following: Group 1 (WZ)-Dura white stone followed by Shofu zirconia polishing kit; Group 2 (SZ)-Shofu zirconia polishing kit; Group 3 (CE)-Ceramiste porcelain polishers; Group 4 (CM)-Ceramaster porcelain polishers; and Group 5 (KZ)-Komet ZR zirconia polishers. All specimens were ground with a fine-grit diamond bur prior to polishing procedures to simulate clinical finishing. Baseline and post-polishing profilometric readings were recorded and delta Ra values (difference in mean surface roughness before and after polishing) were computed and analyzed using one-way analysis of variance and Scheffe post hoc test (p<0.05). Representative scanning electron microscopy (SEM) images of the ground but unpolished and polished specimens were acquired. Delta Ra values ranged from 0.146 for CE to 0.400 for KZ. Delta Ra values for KZ, WZ, and SZ were significantly greater than for CE. Significant differences in delta Ra values were also observed between KZ and CM. The SEM images obtained were consistent with the profilometric findings. Diamond-impregnated polishing systems were more effective than silica carbide-impregnated ones in reducing the surface roughness of ground monolithic zirconia.

  7. Convergent Polishing: A Simple, Rapid, Full Aperture Polishing Process of High Quality Optical Flats & Spheres

    PubMed Central

    Suratwala, Tayyab; Steele, Rusty; Feit, Michael; Dylla-Spears, Rebecca; Desjardin, Richard; Mason, Dan; Wong, Lana; Geraghty, Paul; Miller, Phil; Shen, Nan

    2014-01-01

    Convergent Polishing is a novel polishing system and method for finishing flat and spherical glass optics in which a workpiece, independent of its initial shape (i.e., surface figure), will converge to final surface figure with excellent surface quality under a fixed, unchanging set of polishing parameters in a single polishing iteration. In contrast, conventional full aperture polishing methods require multiple, often long, iterative cycles involving polishing, metrology and process changes to achieve the desired surface figure. The Convergent Polishing process is based on the concept of workpiece-lap height mismatch resulting in pressure differential that decreases with removal and results in the workpiece converging to the shape of the lap. The successful implementation of the Convergent Polishing process is a result of the combination of a number of technologies to remove all sources of non-uniform spatial material removal (except for workpiece-lap mismatch) for surface figure convergence and to reduce the number of rogue particles in the system for low scratch densities and low roughness. The Convergent Polishing process has been demonstrated for the fabrication of both flats and spheres of various shapes, sizes, and aspect ratios on various glass materials. The practical impact is that high quality optical components can be fabricated more rapidly, more repeatedly, with less metrology, and with less labor, resulting in lower unit costs. In this study, the Convergent Polishing protocol is specifically described for fabricating 26.5 cm square fused silica flats from a fine ground surface to a polished ~λ/2 surface figure after polishing 4 hr per surface on a 81 cm diameter polisher. PMID:25489745

  8. Efficiency of three different polishing methods on enamel and cementum: A scanning electron microscope study.

    PubMed

    Chowdhary, Zoya; Mohan, Ranjana

    2018-01-01

    Tooth polishing is an integral part of clinical dentistry. The main purpose of polishing is to smoothen the surface of the tooth and minimize the deposition of plaque to allow a healthy periodontal maintenance postscaling. Today, polishing by different methods is available to a clinician. Traditional bristle brush and rubber-cup polishing are being widely practiced and gradually getting replaced by novel air polisher. Pros and cons of each method should be weighed before its clinical applications. To evaluate and compare the efficiency of three different polishing systems on enamel as well as on cementum surfaces by scanning electron microscope (SEM). A total of 120 samples were divided into three groups randomly - Group 1 (bristle brush), Group 2 (rubber cup), and Group 3 (air polisher) - with 20 samples each of enamel and cementum, which were subdivided into 10 control and 10 test group (subjected to polishing). The samples were analyzed by SEM at ×1000 magnification, and the data obtained were compiled and subjected to statistical analysis. Polishing with bristle brush demonstrated less surface roughness and debris when compared to air polisher at P = 0.58, P = 0.03 for enamel surface and P = 0.003, P = 0.21 for cementum, respectively. The surface roughness was reduced considerably by rubber cup at P = 0.03 for enamel and P = 0.003 for cementum, compared to air polisher at P = 0.99 and P = 0.21 for enamel and cementum, respectively. The results indicate that polishing with rubber cup was more effective and statistically significant when compared to bristle brush polishing and air polisher for the crown and root surface smoothening and debris removal.

  9. Attack polish for nickel-base alloys and stainless steels

    DOEpatents

    Not Available

    1980-05-28

    A chemical attack polish and polishing procedure for use on metal surfaces such as nickel base alloys and stainless steels is described. The chemical attack polich comprises FeNO/sub 3/, concentrated CH/sub 3/COOH, concentrated H/sub 2/SO/sub 4/ and H/sub 2/O. The polishing procedure includes saturating a polishing cloth with the chemical attack polish and submicron abrasive particles and buffing the metal surface.

  10. First Giant Mirror for the ESO VLT Ready at REOSC

    NASA Astrophysics Data System (ADS)

    1995-11-01

    The REOSC Contract In 1989, the European Southern Observatory (ESO), the European Organisation for Astronomy, awarded to REOSC, a subsidiary of the SFIM Group and located in Saint Pierre du Perray (France), a comprehensive contract for the polishing of four 8.2-metre diameter mirrors for the unit telescopes of the ESO Very Large Telescope (VLT) project. These mirrors are the largest ever manufactured and polished. This contract comprises not only the polishing and high-precision optical testing of each giant mirror, but also the safe condition of transportation of the blanks which were manufactured by Schott Glaswerke in Mainz (Germany). In order to fulfill the contract, REOSC conceived, built and equipped a novel, high-tech workshop which would allow to polish and test the mirrors, each of which has a surface area of more than 50 square metres. First 8.2-Metre Mirror is Ready and within Specifications The REOSC polishing facility for giant mirrors was built in Saint Pierre du Perray, just south of Paris. It is equipped with two machines: one for grinding and the other for polishing the mirrors, and both with 150-actuator systems that support the thin and flexible mirrors. All equipment is computer controlled. State-of-the-art interferometers probe the accuracy of the mirror surface as the polishing proceeds; they are installed at the top level of the facility in a 30-metre high tower, at the centre of the mirror's radius of curvature. The success of the work at REOSC is now evident by the fact that careful measurements of the first mirror earlier this month have shown that the final optical surface is correct to within 0.00005 millimetres. For illustration, this corresponds to an accuracy of only 1 millimetre deviation over a surface with a diameter of 165 kilometres (equivalent to the entire Paris area)! ESO Receives the First VLT Mirror After having been carefully placed in a special transport box designed by REOSC, the first mirror blank, weighing 23.5 tons and with a replacement value of about 20 million DEM, was transported from Mainz to Saint Pierre du Perray in July 1993. The shaping and polishing phases lasted two years and were completed in October 1995. After one month's hard work, dedicated to optical and mechanical verifications by ESO and REOSC, the mirror's various characteristics have now been found to be in accordance with the contract specifications. Following the technical acceptance, the first mirror was re-installed in its transport container on November 13, 1995. It will thereafter be formally handed over to ESO during a ceremony at REOSC on Tuesday, November 21, 1995. The mirror will be stored at the REOSC facility until its future departure to ESO's VLT Observatory on Cerro Paranal, a 2650 m high summit in the Andean Cordillera in northern Chile. Here it will be installed in the first VLT unit telescope, soon after the assembly of the mechanical parts has been completed. Future Plans at REOSC The polishing of the second VLT mirror, as well as the grinding of the third mirror which was transported from Mainz to Saint Pierre du Perray at the beginning of October 1995, have already started. The transport of the fourth blank will take place in March 1996. With the construction, in a subsequent phase, of a workshop of more than 6000 square metres and mostly dedicated to space and astronomy, the SFIM group will have invested more than 50 million French Francs at the Saint Pierre du Perray site alone. The group is also involved in the contract related to the actuator support system; this is a clear indication of its determination to maintain its position within this scientific-technological market. In addition to the ESO VLT mirrors, REOSC will also polish the two 8.2-metre diameter mirrors of the Gemini programme of the Association of Universities for Research in Astronomy (AURA) in the United States. This important work was entrusted REOSC, following an international call for tenders, in which also US firms participated. How to obtain ESO Press Information ESO Press Information is made available on the World-Wide Web (URL: http://www.eso.org../). ESO Press Photos may be reproduced, if credit is given to the European Southern Observatory.

  11. Self-reported quality of life in multiple sclerosis patients: preliminary results based on the Polish MS Registry.

    PubMed

    Brola, Waldemar; Sobolewski, Piotr; Fudala, Małgorzata; Flaga, Stanisław; Jantarski, Konrad; Ryglewicz, Danuta; Potemkowski, Andrzej

    2016-01-01

    The aim of the study was to analyze selected clinical and sociodemographic factors and their effects on the quality of life (QoL) of multiple sclerosis (MS) patients registered in the Polish MS Registry. This was a cross-sectional observational study performed in Poland. Data on personal and disease-specific factors were collected between January 1, 2011, and December 31, 2015, via the web portal of the Polish MS Registry. All patients were assessed by a physician and asked to complete the Polish language versions of the following self-evaluation questionnaires: EuroQol 5-Dimensions, EuroQoL Visual Analog Scale, and Multiple Sclerosis Impact Scale. Univariate analysis and logistic regression were performed to determine the factors associated with QoL. The study included 2,385 patients (female/male ratio 2.3:1) with clinically confirmed MS (mean age 37.8±9.2 years). Average EuroQol 5-Dimensions index was 0.72±0.24, and the mean EuroQoL Visual Analog Scale score was 64.2±22.8. The average Multiple Sclerosis Impact Scale score was 84.6±11.2 (62.2±18.4 for physical condition and 23.8±7.2 for mental condition). Lower QoL scores were significantly associated with higher level of disability (odds ratio [OR], 0.932; 95% confidence interval [CI], 0.876-0.984; P=0.001), age >40 years (OR, 1.042; 95% CI, 0.924-1.158; P=0.012), longer disease duration (OR, 0.482; 95% CI, 0.224-0.998; P=0.042), and lack of disease modifying therapies (OR, 0.024; 95% CI, 0.160-0.835; P=0.024). No significant associations were found between QoL, sex, type of MS course, patient's education, and marital status. The Polish MS Registry is the first national registry for long-term observation that allows for self-evaluation of the QoL. QoL of Polish patients with MS is significantly lower compared with the rest of the population. The parameter is mainly affected by the level of disability, duration of the disease, and limited access to immunomodulatory therapy.

  12. Slower nicotine metabolism among postmenopausal Polish smokers.

    PubMed

    Kosmider, Leon; Delijewski, Marcin; Koszowski, Bartosz; Sobczak, Andrzej; Benowitz, Neal L; Goniewicz, Maciej L

    2018-06-01

    A non-invasive phenotypic indicator of the rate of nicotine metabolism is nicotine metabolite ratio (NMR) defined as a ratio of two major metabolites of nicotine - trans-3'-hydroxycotinine/cotinine. The rate of nicotine metabolism has important clinical implications for the likelihood of successful quitting with nicotine replacement therapy (NRT). We conducted a study to measure NMR among Polish smokers. In a cross-sectional study of 180 daily cigarette smokers (42% men; average age 34.6±13.0), we collected spot urine samples and measured trans-3'-hydroxycotinine (3-HC) and cotinine levels with LC-MS/MS method. We calculated NMR (molar ratio) and analyzed variations in NMR among groups of smokers. In the whole study group, an average NMR was 4.8 (IQR 3.4-7.3). The group of women below 51 years had significantly greater NMR compared to the rest of the population (6.4; IQR 4.1-8.8 vs. 4.3; IQR 2.8-6.4). No differences were found among group ages of male smokers. This is a first study to describe variations in nicotine metabolism among Polish smokers. Our findings indicate that young women metabolize nicotine faster than the rest of population. This finding is consistent with the known effects of estrogen to induce CYP2A6 activity. Young women may require higher doses of NRT or non-nicotine medications for most effective smoking cessation treatment. Copyright © 2017 Institute of Pharmacology, Polish Academy of Sciences. Published by Elsevier B.V. All rights reserved.

  13. The realuminizing of the 7-meter-diameter solar simulator collimating mirror

    NASA Technical Reports Server (NTRS)

    Noller, E. W.

    1994-01-01

    This paper describes the modification of a three-electron-beam (EB) gun system for vacuum depositing a highly reflective aluminum coating on a 7.01-m (23-ft) -diam nickel-plated aluminum collimating mirror. The mirror is part of the JPL 7.62-m space simulator that was recently modernized with a new high vacuum pumping system, solar lamp power supplies, solar optic lens system, and refurbished collimating mirror. The 7.01-m 12,700-kg (14-ton) spherical collimating mirror was removed from this facility for replating with 381 micron (0.015 in.) of electroless nickel and polished to a specular finish for realuminizing. The space chamber served as the vacuum coating vessel for the realuminizing coating process. The mirror is the primary reflector for the solar simulation system and the aluminized reflective surface is its most critical performance element. The uniformity of thickness and high reflectivity of the coating in visible and near-ultraviolet (UV) light governs the accuracy of the beam for solar testing. The uniformity of the thin-film thickness also controls the durability of the mirror over time. The mirror was polished to a 64-percent reflectivity with a uniformity of 1.5 percent. The performance goal for the aluminizing was 89 percent with +/- 0.5-percent variation over the mirror.

  14. Influence of orthodontic adhesives and clean-up procedures on the stain susceptibility of enamel after debonding.

    PubMed

    Joo, Hyun-Jin; Lee, Yong-Keun; Lee, Dong-Yul; Kim, Yae-Jin; Lim, Yong-Kyu

    2011-03-01

    To determine the influence of the type of orthodontic adhesive system, such as conventional acid-etching (CE) and self-etching primers (SEPs), on the stain susceptibility of enamel surface after debonding. Effects of clean-up procedures on the enamel surface were also determined. Two types and four brands of adhesive systems were investigated using 135 human premolars. Unbonded teeth were used as controls. Three-dimensional scanning of the enamel surface was performed before bracket bonding, after debonding, and after clean-up procedures. The color of each tooth was measured before bracket bonding and again after debonding and clean-up procedures. This was followed by methylene blue staining. The stain susceptibility of the enamel surface was measured after finishing only (F-condition) and after finishing/polishing (FP-condition). After debonding, the amount of residual adhesive resins in CE materials was greater than that in SEP materials. For the F-condition, staining color change in SEP materials was significantly higher than that in CE materials. For the FP-condition, staining color change in both CE and SEP materials was not different from those of the control. The SEP system would show less stain susceptibility if the thin residual adhesive resin layer after debonding is removed by polishing.

  15. Electrochemical polishing of notches

    DOEpatents

    Kephart, A.R.; Alberts, A.H.

    1989-02-21

    An apparatus and method are disclosed for the selective electrochemical polishing of a lateral tip of a deep longitudinal notch in a work piece used to test crack initiation properties of materials. A DC power source is connected to the work piece and to an electrode disposed laterally along the distal end of an insulated body which is inserted in the longitudinal notch. The electrode and distal end of the body are disposed along the tip of the notch, but are spaced from the notch so as to provide a lateral passage for an electrolyte. The electrolyte is circulated through the passage so that the electrolyte only contacts the work piece adjacent the passage. Conveniently, the electrolyte is circulated by use of an inlet tube and an outlet tube provided at opposite ends of the passage. These tubes are preferably detachably located adjacent the ends of the passage and suitable seals are provided. A holding device including arms to which the tubes are attached is conveniently used to rapidly and easily locate the test specimen with the passage aligned with the tubes. The electrode is preferably a wire which is located in grooves along the distal end of the insulated body and up one side of the body or a plastic sheath insulated thin metal strip. 4 figs.

  16. Electrochemical polishing of notches

    DOEpatents

    Kephart, Alan R.; Alberts, Alfred H.

    1989-01-01

    An apparatus and method are disclosed for the selective electrochemical polishing of a lateral tip of a deep longitudinal notch in a work piece used to test crack initiation properties of materials. A DC power source is connected to the work piece and to an electrode disposed laterally along the distal end of an insulated body which is inserted in the longitudinal notch. The electrode and distal end of the body are disposed along the tip of the notch, but are spaced from the notch so as to provide a lateral passage for an electrolyte. The electrolyte is circulated through the passage so that the electrolyte only contacts the work piece adjacent the passage. Conveniently, the electrolyte is circulated by use of an inlet tube and an outlet tube provided at opposite ends of the passage. These tubes are preferably detachably located adjacent the ends of the passage and suitable seals are provided. A holding device including arms to which the tubes are attached is conveniently used to rapidly and easily locate the test specimen with the passage aligned with the tubes. The electrode is preferably a wire which is located in grooves along the distal end of the insulated body and up one side of the body or a plastic sheath insulated thin metal strip.

  17. Simultaneous ion sputter polishing and deposition

    NASA Technical Reports Server (NTRS)

    Rutledge, S.; Banks, B.; Brdar, M.

    1981-01-01

    Results of experiments to study ion beam sputter polishing in conjunction with simultaneous deposition as a mean of polishing copper surfaces are presented. Two types of simultaneous ion sputter polishing and deposition were used in these experiments. The first type utilized sputter polishing simultaneous with vapor deposition, and the second type utilized sputter polishing simultaneous with sputter deposition. The etch and deposition rates of both techniques were studied, as well as the surface morphology and surface roughness.

  18. Super-polishing of Zerodur aspheres by means of conventional polishing technology

    NASA Astrophysics Data System (ADS)

    Polak, Jaroslav; Klepetková, Eva; Pošmourný, Josef; Šulc, Miroslav; Procháska, František; Tomka, David; Matoušek, Ondřej; Poláková, Ivana; Šubert, Eduard

    2015-01-01

    This paper describes a quest to find simple technique to superpolish Zerodur asphere (55μm departure from best fit sphere) that could be employed on old fashion way 1-excenter optical polishing machine. The work focuses on selection of polishing technology, study of different polishing slurries and optimization of polishing setup. It is demonstrated that either by use of fine colloidal CeO2 slurry or by use of bowl-feed polishing setup with CeO2 charged pitch we could reach 0.4nm RMS roughness while removing <30nm of surface layer. This technique, although not optimized, was successfully used to improve surface roughness on already prepolished Zerodur aspheres without necessity to involve sophisticated super-polishing technology and highly trained manpower.

  19. Research of polishing process to control the iron contamination on the magnetorheological finished KDP crystal surface.

    PubMed

    Chen, Shaoshan; Li, Shengyi; Peng, Xiaoqiang; Hu, Hao; Tie, Guipeng

    2015-02-20

    A new nonaqueous and abrasive-free magnetorheological finishing (MRF) method is adopted for processing a KDP crystal. MRF polishing is easy to result in the embedding of carbonyl iron (CI) powders; meanwhile, Fe contamination on the KDP crystal surface will affect the laser induced damage threshold seriously. This paper puts forward an appropriate MRF polishing process to avoid the embedding. Polishing results show that the embedding of CI powders can be avoided by controlling the polishing parameters. Furthermore, on the KDP crystal surface, magnetorheological fluids residua inevitably exist after polishing and in which the Fe contamination cannot be removed completely by initial ultrasonic cleaning. To solve this problem, a kind of ion beam figuring (IBF) polishing is introduced to remove the impurity layer. Then the content of Fe element contamination and the depth of impurity elements are measured by time of flight secondary ion mass spectrometry. The measurement results show that there are no CI powders embedding in the MRF polished surface and no Fe contamination after the IBF polishing process, respectively. That verifies the feasibility of MRF polishing-IBF polishing (cleaning) for processing a KDP crystal.

  20. Diagnostics and Treatment of Thyroid Carcinoma.

    PubMed

    Jarząb, Barbara; Dedecjus, Marek; Handkiewicz-Junak, Daria; Lange, Dariusz; Lewiński, Andrzej; Nasierowska-Guttmejer, Anna; Ruchała, Marek; Słowińska-Klencka, Dorota; Nauman, Janusz; Adamczewski, Zbigniew; Bagłaj, Maciej; Bałdys-Waligórska, Agata; Barczyński, Marcin; Bednarczuk, Tomasz; Cichocki, Andrzej; Czarniecka, Agnieszka; Czepczyński, Rafał; Gawlik, Aneta; Hubalewska-Dydejczyk, Alicja; Jażdżewski, Krystian; Kamiński, Grzegorz; Karbownik-Lewińska, Małgorzata; Kos-Kudła, Beata; Kułakowski, Andrzej; Kuzdak, Krzysztof; Łącka, Katarzyna; Małecka-Tendera, Ewa; Niedziela, Marek; Pomorski, Lech; Sporny, Stanisław; Stojcev, Zoran; Syrenicz, Anhelli; Włoch, Jan; Krajewska, Jolanta; Szpak-Ulczok, Sylwia; Kalemba, Michal; Buziak-Bereza, Monika

    2016-01-01

    Revised Guidelines of Polish National Societies Prepared on the initiative of the Polish Group for Endocrine Tumours approved in their final version between November 16th and 28th, 2015 by the Scientific Committee of the V Conference "Thyroid Cancer and other malignancies of endocrine glands" organised between November 14th and 17th, 2015 in Wisla, Poland; called by the following Societies: Polish Endocrine Society, Polish Society of Oncology, Polish Thyroid Association, Polish Society of Pathologists, Society of Polish Surgeons, Polish Society of Surgical Oncology, Polish Society of Clinical Oncology, Polish Society of Radiation Oncology, Polish Society of Nuclear Medicine, Polish Society of Paediatric Endocrinology, Polish Society of Paediatric Surgeons, Polish Society of Ultrasonography Gliwice-Wisła, 2015 DECLARATION: These recommendations are created by the group of delegates of the National Societies, which declare their willingness to participate in the preparation of the revised version of the Polish Guidelines. The members of the Working Group have been chosen from the specialists involved in medical care of patients with thyroid carcinoma. Directly before the preparation of the Polish national recommendations the American Thyroid Association (ATA) published its own guidelines together with a wide comment fulfilling evidence-based medicine (EBM) criteria. ATA Guidelines are consistent with National Comprehensive Cancer Network (NCCN) Recommendation. According to the members of the Working Group, it is necessary to adapt them to both the specific Polish epidemiological situation as well as to the rules referring to the Polish health system. Therefore, the Polish recommendations constitute a consensus of the experts' group, based on ATA information. The experts analysed previous Polish Guidelines, published in 2010, and other available data, and after discussion summed up the results in the form of these guidelines. It should be added that Part II, which constitutes a pathological part, has been available at the website of the Polish Society of Pathologists for acceptance of the members of the Society, and no essential comments have been proposed. The Members of the Group decided that a subgroup elected from among them would update the Guidelines, according to EBM rules, every year. The Revised Guidelines should help physicians to make reasonable choices in their daily practice; however, the final decision concerning an individual patient should be made by the caring physician responsible for treatment, or optimally by a therapeutic tumour board together with the patient, and should take into consideration the patient's health condition. It should be emphasised that the recommendations may not constitute a strict standard of clinical management imposed on medical staff. The data from clinical trials concerning numerous clinical situations are scarce. In such moments the opinion of the management may differ from the recommendations after considering possible benefits and disadvantages for the patient.

  1. Nanocrystalline diamond thin films on titanium-6 aluminum-4 vanadium alloy temporomandibular joint prosthesis simulants by microwave plasma chemical vapor deposition

    NASA Astrophysics Data System (ADS)

    Fries, Marc Douglas

    A course of research has been performed to assess the suitability of nanocrystal-line diamond (NCD) films on Ti-6Al-4V alloy as wear-resistant coatings in biomedical implant use. A series of temporomandibular (TMJ) joint condyle simulants were polished and acid-passivated as per ASTM F86 standard for surface preparation of implants. A 3-mum-thick coating of NCD film was deposited by microwave plasma chemical vapor deposition (MPCVD) over the hemispherical articulation surfaces of the simulants. Plasma chemistry conditions were measured and monitored by optical emission spectroscopy (OES), using hydrogen as a relative standard. The films consist of diamond grains around 20 nm in diameter embedded in an amorphous carbon matrix, free of any detectable film stress gradient. Hardness averages 65 GPa and modulus measures 600 GPa at a depth of 250 nm into the film surface. A diffuse film/substrate boundary produces a minimal film adhesion toughness (GammaC) of 158 J/m2. The mean RMS roughness is 14.6 +/- 4.2 nm, with an average peak roughness of 82.6 +/- 65.9 nm. Examination of the surface morphology reveals a porous, dendritic surface. Wear testing resulted in two failed condylar coatings out of three tests. No macroscopic delamination was found on any sample, but micron-scale film pieces broke away, exposing the substrate. Electrochemical corrosion testing shows a seven-fold reduction in corrosion rate with the application of an NCD coating as opposed to polished, passivated Ti-6Al-4V, producing a corrosion rate comparable to wrought Co-Cr-Mo. In vivo biocompatibility testing indicates that implanted NCD films did not elicit an immune response in the rabbit model, and osteointegration was apparent for both compact and trabecular bone on both NCD film and bare Ti-6Al-4V. Overall, NCD thin film material is reasonably smooth, biocompatible, and very well adhered. Wear testing indicates that this material is unacceptable for use in demanding TMJ applications without improvements to wear resistance behavior. Identified problems include high surface roughness due to an inadequate seeding procedure and a porous film surface. It is believed that these problems can be solved by future research, in which case NCD thin films should prove to-be well-suited as wear resistant coatings in biomedical applications.

  2. Detection of endolithic spatial distribution in marble stone.

    PubMed

    Casanova Municchia, A; Percario, Z; Caneva, G

    2014-10-01

    The penetration of endolithic microorganisms, which develop to depths of several millimetres or even centimetres into the stone, and the diffusion of their extracellular substances speeds up the stone deterioration process. The aim of this study was to investigate, using a confocal laser scanning microscopy with a double-staining, a marble rock sample by observing the endolithic spatial distribution and quantifying the volume they occupied within the stone, in order to understand the real impact of these microorganisms on the conservation of stone monuments. Often the only factors taken into account by biodeterioration studies regarding endolithic microorganisms, are spread and depth of penetration. Despite the knowledge of three-dimensional spatial distribution and quantification of volume, it is indispensable to understand the real damage caused by endolithic microorganisms to stone monuments. In this work, we analyze a marble rock sample using a confocal laser scanning microscopy stained with propidium iodide and Concavalin-A conjugate with the fluorophore Alexa Fluor 488, comparing these results with other techniques (SEM microscope, microphotographs of polished cross-sections and thin-section, PAS staining methods), An image analysis approach has also been applied. The use of confocal laser scanning microscopy with double staining shows clear evidence of the presence of endolithic microorganisms (cyanobacteria and fungi) as well as the extracellular polymeric substance matrix in a three-dimensional architecture as part of the rock sample, this technique, therefore, seems very useful when applied to restoration interventions on stone monuments when endolithic growth is suspected. © 2014 The Authors Journal of Microscopy © 2014 Royal Microscopical Society.

  3. A statistical approach to estimate the 3D size distribution of spheres from 2D size distributions

    USGS Publications Warehouse

    Kong, M.; Bhattacharya, R.N.; James, C.; Basu, A.

    2005-01-01

    Size distribution of rigidly embedded spheres in a groundmass is usually determined from measurements of the radii of the two-dimensional (2D) circular cross sections of the spheres in random flat planes of a sample, such as in thin sections or polished slabs. Several methods have been devised to find a simple factor to convert the mean of such 2D size distributions to the actual 3D mean size of the spheres without a consensus. We derive an entirely theoretical solution based on well-established probability laws and not constrained by limitations of absolute size, which indicates that the ratio of the means of measured 2D and estimated 3D grain size distribution should be r/4 (=.785). Actual 2D size distribution of the radii of submicron sized, pure Fe0 globules in lunar agglutinitic glass, determined from backscattered electron images, is tested to fit the gamma size distribution model better than the log-normal model. Numerical analysis of 2D size distributions of Fe0 globules in 9 lunar soils shows that the average mean of 2D/3D ratio is 0.84, which is very close to the theoretical value. These results converge with the ratio 0.8 that Hughes (1978) determined for millimeter-sized chondrules from empirical measurements. We recommend that a factor of 1.273 (reciprocal of 0.785) be used to convert the determined 2D mean size (radius or diameter) of a population of spheres to estimate their actual 3D size. ?? 2005 Geological Society of America.

  4. [Surface characteristics of the acrylic resins according to the polishing methods].

    PubMed

    Vitalariu, Anca Mihaela; Lazăr, Lenuţa; Buruiană, Tinca; Diaconu, Diana; Tatarciuc, Monica Silvia

    2011-01-01

    The objective of this study was to evaluate the effect of the polishing technique and glazing on the porosity of the dental resins. The studied resins were: Castapress/Vertex, Prothyl Hot/Zermack, Rapid Simplified/Vertex, Duracryl Plus/Spofa Dental, Vertex-Soft/Vertex, Superacryl Plus/Spofa Dental. Thirty specimens, five for every resin, of 50/25/2 cm in size were done. One surface of each sample was polished with extrahard tungsten carbide burs, the other surface being polished with extrahard extrafine and diamond burs. The final polishing was done using a conventional method: pumice, water and lathe bristle brush for 90 seconds, 1500 rpm and soft leather polishing wheel for 90 seconds, 3000 rpm. Twenty surfaces were glazed after polishing with Glaze/Bosworth. Vertex Soft specimens were not polished because this is a resilient material. Surface porosity of the acrylic resin specimens was measured by optical microscopy. The lowest porosity was obtained by conventional polishing combined with glazing techniques. No differences between glazed and non/glazed self-curing resin specimens were noticed, but there were differences between self-curing and heat-curing resins. Conventional lathe polishing method is an effective and reliable technique for polishing dental resins. Specimens of self-curing resin had a higher porosity than heat curing resin following the same surface treatment. Higher surface smoothness was obtained by conventional lathe polishing completed by glazing.

  5. Experimental Study on the Effects of Alumina Abrasive Particle Behavior in MR Polishing for MEMS Applications

    PubMed Central

    Kim, Dong-Woo; Cho, Myeong-Woo; Seo, Tae-Il; Shin, Young-Jae

    2008-01-01

    Recently, the magnetorheological (MR) polishing process has been examined as a new ultra-precision polishing technology for micro parts in MEMS applications. In the MR polishing process, the magnetic force plays a dominant role. This method uses MR fluids which contains micro abrasives as a polishing media. The objective of the present research is to shed light onto the material removal mechanism under various slurry conditions for polishing and to investigate surface characteristics, including shape analysis and surface roughness measurement, of spots obtained from the MR polishing process using alumina abrasives. A series of basic experiments were first performed to determine the optimum polishing conditions for BK7 glass using prepared slurries by changing the process parameters, such as wheel rotating speed and electric current. Using the obtained results, groove polishing was then performed and the results are investigated. Outstanding surface roughness of Ra=3.8nm was obtained on the BK7 glass specimen. The present results highlight the possibility of applying this polishing method to ultra-precision micro parts production, especially in MEMS applications. PMID:27879705

  6. Growth of high-quality thin-film Ge single crystals by plasma-enhanced chemical vapor deposition

    NASA Technical Reports Server (NTRS)

    Outlaw, R. A.; Hopson, P., Jr.

    1986-01-01

    Thin-film Ge single crystals (approx. 10 microns) have been epitaxially grown on polished NaCl(100) substrates at 450C by using plasma-enhanced chemical vapor deposition. Films on approximately 1 sq cm and larger were separated from the NaCl by either melting the salt or by differential shear stress upon cooling to room temperature. The ordered growth of the Ge was found to be most sensitive to the initial plasma power and to the continuum flow dynamics within the carbon susceptor. The films were visually specular and exhibited a high degree of crysalline order when examined by X-ray diffraction. The films were found to be p-type with a carrier concentration of approximately 3 x 10 to the 16th power/cu cm, a resistivity of 0.11 ohm-cm, and a Hall hole mobility of 1820 sq cm/v/s at room temperature. Vacuum firing minimized the primary contaminant, Na, and corresponding lowered the carrier concentration to 4 x 10 to the 14th power/cu cm.

  7. A hydrogen leak-tight, transparent cryogenic sample container for ultracold-neutron transmission measurements

    NASA Astrophysics Data System (ADS)

    Döge, Stefan; Hingerl, Jürgen

    2018-03-01

    The improvement of the number of extractable ultracold neutrons (UCNs) from converters based on solid deuterium (sD2) crystals requires a good understanding of the UCN transport and how the crystal's morphology influences its transparency to the UCNs. Measurements of the UCN transmission through cryogenic liquids and solids of interest, such as hydrogen (H2) and deuterium (D2), require sample containers with thin, highly polished and optically transparent windows and a well defined sample thickness. One of the most difficult sealing problems is that of light gases like hydrogen and helium at low temperatures against high vacuum. Here we report on the design of a sample container with two 1 mm thin amorphous silica windows cold-welded to aluminum clamps using indium wire gaskets, in order to form a simple, reusable, and hydrogen-tight cryogenic seal. The container meets the above-mentioned requirements and withstands up to 2 bar hydrogen gas pressure against isolation vacuum in the range of 10-5 to 10-7 mbar at temperatures down to 4.5 K. Additionally, photographs of the crystallization process are shown and discussed.

  8. Oxide nucleation on thin films of copper during in situ oxidation in an electron microscope

    NASA Technical Reports Server (NTRS)

    Heinemann, K.; Rao, D. B.; Douglass, D. L.

    1975-01-01

    Single-crystal copper thin films were oxidized at an isothermal temperature of 425 C and at an oxygen partial pressure of 0.005 torr. Specimens were prepared by epitaxial vapor deposition onto polished faces of rocksalt and were mounted in a hot stage inside the ultrahigh-vacuum chamber of a high-resolution electron microscope. An induction period of roughly 30 min was established which was independent of the film thickness but depended strongly on the oxygen partial pressure and to exposure to oxygen prior to oxidation. Neither stacking faults nor dislocations were found to be associated with the Cu2O nucleation sites. The experimental data, including results from oxygen dissolution experiments and from repetitive oxidation-reduction-oxidation sequences, fit well into the framework of an oxidation process involving the formation of a surface charge layer, oxygen saturation of the metal with formation of a supersaturated zone near the surface, and nucleation followed by surface diffusion of oxygen and bulk diffusion of copper for lateral and vertical oxide growth, respectively.

  9. Controlled thickness and dielectric constant titanium-doped SiO2 thin films on silicon by sol gel process

    NASA Astrophysics Data System (ADS)

    Liu, H. L.; Wang, S. S.; Zhou, Yan; Lam, Yee Loy; Chan, Yuen Chuen; Kam, Chan Hin

    1997-08-01

    In this paper, we report the preparation of crack-free relatively thick SiO2-TiO2 thin films on silicon substrates using the sol-gel spin-coating method. The influence of the process parameters on the quality of the film, such as the solution condition, the spin-coating speed, the heat treatment temperature and time, have been studied. We found that the cracking of the film could be avoided by selecting the right sol composition ratios, adding PVA to the sold and properly controlling the heat treatment. Most importantly, we discovered that by polishing the edges of the film after the deposition of each single layer, the number of such layers that deposited without crack formation could be substantially increased. The refractive index profile and thickness of the film have been determined using prism coupling technique and the inverse WKB method. The refractive index was found to depend on the content of TiO2 as well as the heat treatment condition. Using an AFM, the surface morphology of the film was found to be good.

  10. Testing SgrA{sup *} with the spectrum of its accretion structure

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lin, Nan; Li, Zilong; Bambi, Cosimo

    2015-09-01

    SgrA{sup *} is the supermassive black hole candidate at the center of the Galaxy and an ideal laboratory to test general relativity. Following previous work by other authors, we use the Polish doughnut model to describe an optically thin and constant angular momentum ion torus in hydrodynamical equilibrium and model the accretion structure around SgrA{sup *}. The radiation mechanisms are bremsstrahlung, synchrotron emission, and inverse Compton scattering. We compute the spectrum as seen by a distant observer in Kerr and non-Kerr spacetimes and we study how an accurate measurement can constrain possible deviations form the Kerr solution. As in themore » case of emission from a thin accretion disk, we find a substantial degeneracy between the determination of the spin and of possible deviations from the Kerr geometry, even when the parameters of the ion torus are fixed. This means that this technique cannot independently test the nature of SgrA{sup *} even in the presence of good data and with the systematics under control. However, it might do it in combination with other measurements (black hole shadow, radio pulsar, etc.)« less

  11. Wafer-level fabrication of arrays of glass lens doublets

    NASA Astrophysics Data System (ADS)

    Passilly, Nicolas; Perrin, Stéphane; Albero, Jorge; Krauter, Johann; Gaiffe, Olivier; Gauthier-Manuel, Ludovic; Froehly, Luc; Lullin, Justine; Bargiel, Sylwester; Osten, Wolfgang; Gorecki, Christophe

    2016-04-01

    Systems for imaging require to employ high quality optical components in order to dispose of optical aberrations and thus reach sufficient resolution. However, well-known methods to get rid of optical aberrations, such as aspherical profiles or diffractive corrections are not easy to apply to micro-optics. In particular, some of these methods rely on polymers which cannot be associated when such lenses are to be used in integrated devices requiring high temperature process for their further assembly and separation. Among the different approaches, the most common is the lens splitting that consists in dividing the focusing power between two or more optical components. In here, we propose to take advantage of a wafer-level technique, devoted to the generation of glass lenses, which involves thermal reflow in silicon cavities to generate lens doublets. After the convex lens sides are generated, grinding and polishing of both stack sides allow, on the first hand, to form the planar lens backside and, on the other hand, to open the silicon cavity. Nevertheless, silicon frames are then kept and thinned down to form well-controlled and auto-aligned spacers between the lenses. Subsequent accurate vertical assembly of the glass lens arrays is performed by anodic bonding. The latter ensures a high level of alignment both laterally and axially since no additional material is required. Thanks to polishing, the generated lens doublets are then as thin as several hundreds of microns and compatible with micro-opto-electro-systems (MOEMS) technologies since they are only made of glass and silicon. The generated optical module is then robust and provide improved optical performances. Indeed, theoretically, two stacked lenses with similar features and spherical profiles can be almost diffraction limited whereas a single lens characterized by the same numerical aperture than the doublet presents five times higher wavefront error. To demonstrate such assumption, we fabricated glass lens doublets and compared them to single lenses of equivalent focusing power. For similar illumination, the optical aberrations are significantly reduced.

  12. Chemistry and Formation of the Beilby Layer During Polishing of Fused Silica Glass

    DOE PAGES

    Suratwala, Tayyab; Steele, William; Wong, Lana; ...

    2015-05-19

    The chemical characteristics and the proposed formation mechanisms of the modified surface layer (called the Beilby layer) on polished fused silica glasses are described. Fused silica glass samples were polished using different slurries, polyurethane pads, and at different rotation rates. The concentration profiles of several key contaminants, such as Ce, K, and H, were measured in the near surface layer of the polished samples using Secondary Ion Mass Spectroscopy (SIMS). The penetration of K, originating from KOH used for pH control during polishing, decreased with increase in polishing material removal rate. In contrast, penetration of the Ce and H increasedmore » with increase in polishing removal rate. In addition, Ce penetration was largely independent of the other polishing parameters (e.g., particle size distribution and the properties of the polishing pad). The resulting K concentration depth profiles are described using a two-step diffusion process: (1) steady-state moving boundary diffusion (due to material removal during polishing) followed by (2) simple diffusion during ambient postpolishing storage. Using known alkali metal diffusion coefficients in fused silica glass, this diffusion model predicts concentration profiles that are consistent with the measured data at various polishing material removal rates. On the other hand, the observed Ce profiles are inconsistent with diffusion based transport. Rather we propose that Ce penetration is governed by the ratio of Ce–O–Si and Si–O–Si hydrolysis rates; where this ratio increases with interface temperature (which increases with polishing material removal rate) resulting in greater Ce penetration into the Beilby layer. Calculated Ce surface concentrations using this mechanism are in good agreement to the observed change in measured Ce surface concentrations with polishing material removal rate. In conclusion, these new insights into the chemistry of the Beilby layer, combined together with details of the single particle removal function during polishing, are used to develop a more detailed and quantitative picture of the polishing process and the formation of the Beilby layer.« less

  13. 21 CFR 872.6290 - Prophylaxis cup.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Prophylaxis cup. 872.6290 Section 872.6290 Food... DEVICES DENTAL DEVICES Miscellaneous Devices § 872.6290 Prophylaxis cup. (a) Identification. A prophylaxis cup is a device made of rubber intended to be held by a dental handpiece and used to apply polishing...

  14. 21 CFR 872.6290 - Prophylaxis cup.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Prophylaxis cup. 872.6290 Section 872.6290 Food... DEVICES DENTAL DEVICES Miscellaneous Devices § 872.6290 Prophylaxis cup. (a) Identification. A prophylaxis cup is a device made of rubber intended to be held by a dental handpiece and used to apply polishing...

  15. Cancer--Living with Cancer - Multiple Languages

    MedlinePlus

    ... français) Haitian Creole (Kreyol ayisyen) Hindi (हिन्दी) Japanese (日本語) Korean (한국어) Nepali (नेपाली) Polish (polski) ... Families - हिन्दी (Hindi) PDF American Cancer Society Japanese (日本語) Expand Section Cancer Related Fatigue - 日本語 (Japanese) ...

  16. Cancer Chemotherapy - Multiple Languages

    MedlinePlus

    ... français) Haitian Creole (Kreyol ayisyen) Hindi (हिन्दी) Japanese (日本語) Korean (한국어) Nepali (नेपाली) Polish (polski) ... हिन्दी (Hindi) Bilingual PDF Health Information Translations Japanese (日本語) Expand Section Cancer Chemotherapy - 日本語 (Japanese) Bilingual ...

  17. Laboratory Tests - Multiple Languages

    MedlinePlus

    ... français) Haitian Creole (Kreyol ayisyen) Hindi (हिन्दी) Japanese (日本語) Korean (한국어) Polish (polski) Russian (Русский) Somali ( ... Tests - हिन्दी (Hindi) PDF American Cancer Society Japanese (日本語) Expand Section 24-Hour Urine Test - 日本語 ( ...

  18. Flat ion milling: a powerful tool for preparation of cross-sections of lead-silver alloys.

    PubMed

    Brodusch, Nicolas; Boisvert, Sophie; Gauvin, Raynald

    2013-06-01

    While conventional mechanical and chemical polishing results in stress, deformation and polishing particles embedded on the surface, flat milling with Ar+ ions erodes the material with no mechanical artefacts. This flat milling process is presented as an alternative method to prepare a Pb-Ag alloy cross-section for scanning electron microscopy. The resulting surface is free of scratches with very little to no stress induced, so that electron diffraction and channelling contrast are possible. The results have shown that energy dispersive spectrometer (EDS) mapping, electron channelling contrast imaging and electron backscatter diffraction can be conducted with only one sample preparation step. Electron diffraction patterns acquired at 5 keV possessed very good pattern quality, highlighting an excellent surface condition. An orientation map was acquired at 20 keV with an indexing rate of 90.1%. An EDS map was performed at 5 keV, and Pb-Ag precipitates of sizes lower than 100 nm were observed. However, the drawback of the method is the generation of a noticeable surface topography resulting from the interaction of the ion beam with a polycrystalline and biphasic sample.

  19. Dual use of electronic and tobacco cigarettes among adolescents: a cross-sectional study in Poland.

    PubMed

    Goniewicz, Maciej L; Leigh, Noel J; Gawron, Michal; Nadolska, Justyna; Balwicki, Lukasz; McGuire, Connor; Sobczak, Andrzej

    2016-03-01

    Electronic cigarettes (e-cigarettes) are gaining in popularity among youth. While these products may be beneficial in adult smokers, the effect on young users of electronic and tobacco cigarettes (dual users) is unknown. The objective of this study was to assess the frequency of dual use among adolescents and to compare tobacco cigarette consumption among dual and exclusive tobacco cigarette users. A cross-sectional survey of a sample of 2213 Polish students aged 16-18 conducted between December 2013 and February 2014. Overall, 21.8 % of students were dual users. Dual users were more likely to smoke tobacco cigarettes on a daily basis [adjusted odds ratio, AOR 3.54 (95 % CI 2.34-5.36) and less likely to smoke fewer cigarettes per day (AOR 0.27 (95 % CI 0.12-0.57)] than exclusive tobacco cigarette users. The frequency of dual use was higher than exclusive use of a single product among Polish adolescents. Young dual users do not smoke a lower number of tobacco cigarettes per day than exclusive tobacco cigarette users.

  20. Apollo-11 lunar sample information catalogue

    NASA Technical Reports Server (NTRS)

    Kramer, F. E. (Compiler); Twedell, D. B. (Compiler); Walton, W. J. A., Jr. (Compiler)

    1977-01-01

    The Apollo 11 mission is reviewed with emphasis on the collection of lunar samples, their geologic setting, early processing, and preliminary examination. The experience gained during five subsequent missions was applied to obtain physical-chemical data for each sample using photographic and binocular microscope techniques. Topics discussed include: binocular examination procedure; breccia clast dexrriptuons, thin section examinations procedure typical breccia in thin section, typical basalt in thin section, sample histories, and chemical and age data. An index to photographs is included.

  1. Thin-Section Computed Tomography Manifestations During Convalescence and Long-Term Follow-Up of Patients with Severe Acute Respiratory Syndrome (SARS).

    PubMed

    Wu, Xiaohua; Dong, Dawei; Ma, Daqing

    2016-08-08

    BACKGROUND SARS is not only an acute disease, but also leads to long-term impaired lung diffusing capacity in some survivors. However, there is a paucity of data regarding long-term CT findings in survivors after SARS. The aim of this study was to assess the changes in lung function and lung thin-section computed tomography (CT) features in patients recovering from severe acute respiratory syndrome (SARS), especially the dynamic changes in ground-glass opacity (GGO). MATERIAL AND METHODS Clinical and radiological data from 11 patients with SARS were collected. The serial follow-up thin-section CTs were evaluated at 3, 6, and 84 months after SARS presentation. The distribution and predominant thin-section CT findings of lesions were evaluated. RESULTS The extent of the lesions on the CT scans of the 11 patients decreased at 6 and 84 months compared to 3 months. The number of segments involved on 84-month follow-up CTs was less than those at 6 months (P<0.05). The predominant thin-section CT manifestation at 84 months (intralobular and interlobular septal thickening) was different than that at 6 months, at which GGO was predominant. CONCLUSIONS During convalescence after SARS, GGO and intralobular and interlobular septal thickening were the main thin-section CT manifestation. Intralobular and interlobular septal thickening predominated over GGO at 84 months.

  2. Polishing performance of multiple-use silicone rubber-based polishing instruments with and without disinfection/sterilization.

    PubMed

    Heintze, Siegward Dietmar; Forjanic, Monika

    2008-10-01

    To evaluate the effect of the multiple-use of a three-step rubber-based polishing system on the polishing performance with and without a disinfection/sterilization protocol with prolonged disinfection (overnight). The three-step polishing system Astropol was applied under standardized contact pressure of 2 N on 320 grit pre-roughened flat composite specimens of Tetric EvoCeram for 10 seconds (F and P disc) and 30 seconds (HP disc) respectively. After each polishing step, the surface gloss and roughness were measured with a glossmeter and an optical sensor (FRT MicroProf), respectively. Material loss of the composite specimens and polishing instruments were measured after each step with a high precision digital scale. For all four variables (surface gloss, surface roughness, composite loss, loss of rubber material) the mean percentage of change compared to the reference was calculated. Already after the first use, the instruments which were used without disinfection or sterilization demonstrated a statistically significantly reduced polishing performance in all polishing steps compared to the reference (new polishing system) (t-test, P < 0.05). In addition, this loss in performance further increased with the second and third re-use. Especially the third component (Astropol HP) was affected by performance loss. By contrast, the multiple-use of the instruments which were subjected to prolonged disinfection did not result in a reduced polishing performance. For the P disc, a statistically significant improvement of the polishing performance could be observed throughout almost all multiple-use sessions (ANOVA, P < 0.05). The improved polishing performance was, however, accompanied by an increased loss of the silicone rubber material of the P and F polishing discs; the HP discs were not affected by this loss. Furthermore, particles of the rubber material also adhered to the composite. The polishing performance of the discs which were only subjected to the sterilization process was not statistically significantly different to the polishing performance of the control group in terms of surface roughness; but the surface gloss was worse than that of the control group. No loss of rubber material or adherence to the composite was observed in this group.

  3. Health Information in Polish (polski)

    MedlinePlus

    ... Tools You Are Here: Home → Multiple Languages → Polish (polski) URL of this page: https://medlineplus.gov/languages/polish.html Health Information in Polish (polski) To use the sharing features on this page, ...

  4. Several cases of undesirable effects caused by methacrylate ultraviolet-curing nail polish for non-professional use.

    PubMed

    Dahlin, Jakob; Berne, Berit; Dunér, Kari; Hosseiny, Sara; Matura, Mihály; Nyman, Gunnar; Tammela, Monica; Isaksson, Marléne

    2016-09-01

    Ultraviolet (UV)-curing nail polishes based on acrylates or methacrylates are currently also available for non-professional use. The Swedish Medical Products Agency recently prohibited one brand of UV-curing polish, because several consumers reported undesirable effects after using it. To investigate whether consumers with undesirable effects after using the UV-curing nail polish that was later prohibited were contact allergic to the polish and its individual ingredients. Eight patients who had reported severe skin reactions after the use of the UV-curing polish were patch tested with two coatings of the nail polish and its ingredients at five dermatology departments in Sweden. All patients tested except one showed contact allergic reactions to one or several of the acrylate-based or methacrylate-based ingredients in the nail polish. The non-professional use of UV-curing nail polishes poses a risk of sensitization from acrylates and methacrylates. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  5. Methods for making thin layers of crystalline materials

    DOEpatents

    Lagally, Max G; Paskiewicz, Deborah M; Tanto, Boy

    2013-07-23

    Methods for making growth templates for the epitaxial growth of compound semiconductors and other materials are provided. The growth templates are thin layers of single-crystalline materials that are themselves grown epitaxially on a substrate that includes a thin layer of sacrificial material. The thin layer of sacrificial material, which creates a coherent strain in the single-crystalline material as it is grown thereon, includes one or more suspended sections and one or more supported sections.

  6. Novel Thin Film Sensor Technology for Turbine Engine Hot Section Components

    NASA Technical Reports Server (NTRS)

    Wrbanek, John D.; Fralick, Gustave C.

    2007-01-01

    Degradation and damage that develops over time in hot section components can lead to catastrophic failure of the turbine section of aircraft engines. A range of thin film sensor technology has been demonstrated enabling on-component measurement of multiple parameters either individually or in sensor arrays including temperature, strain, heat flux, and flow. Conductive ceramics are beginning to be investigated as new materials for use as thin film sensors in the hot section, leveraging expertise in thin films and high temperature materials. The current challenges are to develop new sensor and insulation materials capable of withstanding the extreme hot section environment, and to develop techniques for applying sensors onto complex high temperature structures for aging studies of hot propulsion materials. The technology research and development ongoing at NASA Glenn Research Center for applications to future aircraft, launch vehicles, space vehicles, and ground systems is outlined.

  7. Effects of Polishing Bur Application Force and Reuse on Sintered Zirconia Surface Topography.

    PubMed

    Fischer, N G; Tsujimoto, A; Baruth, A G

    2018-03-16

    Limited information is available on how to polish and finish zirconia surfaces following computer-aided design/computer-aided manufacturing (CAD/CAM), specifically, how differing application forces and reuse of zirconia polishing systems affect zirconia topography. To determine the effect of differing, clinically relevant, polishing application forces and multiple usages of polishing burs on the surface topography of CAD/CAM zirconia. One hundred twenty 220-grit carbide finished zirconia disks were sintered according to manufacturer's directions and divided into two groups for the study of two coarse polishing bur types. Each group was divided into subgroups for polishing (15,000 rpm) at 15 seconds for 1.0 N, 4.5 N, or 11 N of force using a purpose-built fixture. Subgroups were further divided to study the effects of polishing for the first, fifth, 15th, and 30th bur use, simulating clinical procedures. Unpolished surfaces served as a control group. Surfaces were imaged with noncontact optical profilometry (OP) and atomic force microscopy (AFM) to measure average roughness values (Ra). Polishing burs were optically examined for wear. Scanning electron microscopy (SEM) was performed on burs and zirconia surfaces. One-way ANOVA with post hoc Tukey HSD (honest significant difference) tests (α=0.05) were used for statistical analyses. AFM and OP Ra values of all polished surfaces were significantly lower than those of the unpolished control. Different polishing forces and bur reuse showed no significant differences in AFM Ra. However, significant differences in OP Ra were found due to differing application forces and bur reuse between the first and subsequent uses. SEM and optical micrographs revealed notable bur wear, increasing with increasing reuse. SEM and AFM micrographs clearly showed polished, periodic zirconia surfaces. Nanoscale topography, as analyzed with kurtosis and average groove depth, was found dependent on the specific polishing bur type. These in vitro results suggest changes in OP Ra due to bur reuse and polishing application force. Within the parameters of this study, the resultant topography of zirconia polishing is force-dependent and the reuse of coarse polishing burs is possible without statistically significant differences in Ra values after initial use. Nanoscale and microscale topography were shown to depend on specific polishing bur type.

  8. Mechanical Characterization of Nanoporous Thin Films by Nanoindentation and Laser-induced Surface Acoustic Waves

    NASA Astrophysics Data System (ADS)

    Chow, Gabriel

    Thin films represent a critical sector of modern engineering that strives to produce functional coatings at the smallest possible length scales. They appear most commonly in semiconductors where they form the foundation of all electronic circuits, but exist in many other areas to provide mechanical, electrical, chemical, and optical properties. The mechanical characterization of thin films has been a continued challenge due foremost to the length scales involved. However, emerging thin films focusing on materials with significant porosity, complex morphologies, and nanostructured surfaces produce additional difficulties towards mechanical analysis. Nanoindentation has been the dominant thin film mechanical characterization technique for the last decade because of the quick results, wide range of sample applicability, and ease of sample preparation. However, the traditional nanoindentation technique encounters difficulties for thin porous films. For such materials, alternative means of analysis are desirable and the lesser known laser-induced surface acoustic wave technique (LiSAW) shows great potential in this area. This dissertation focuses on studying thin, porous, and nanostructured films by nanoindentation and LiSAW techniques in an effort to directly correlate the two methodologies and to test the limits and applicabilities of each technique on challenging media. The LiSAW technique is particularly useful for thin porous films because unlike indentation, the substrate is properly accounted for in the wave motion analysis and no plastic deformation is necessary. Additionally, the use of lasers for surface acoustic wave generation and detection allows the technique to be fully non-contact. This is desirable in the measurement of thin, delicate, and porous films where physical sample probing may not be feasible. The LiSAW technique is also valuable in overcoming nanoscale roughness, particularly for films that cannot be mechanically polished, since typical SAW wavelengths are micrometers in scale whereas indentation depths are usually confined to the nanometer scale. This dissertation demonstrates the effectiveness of LiSAW on both thin porous layers and rough surfaces and shows the challenges faced by nanoindentation on the same films. Zeolite thin films are studied extensively in this work as a model system because of their porous crystalline framework and enormous economic market. Many types of zeolite exist and their widely varying structures and levels of porosity present a unique opportunity for mechanical characterization. For a fully dense ZSM-5 type zeolite with wear and corrosion resistance properties, nanoindentation was used to compare its mechanical properties to industrial chromium and cadmium films. Through tribological and indentation tests, it was shown that the zeolite film possesses exceptional resilience and hardness therefore demonstrating superior wear resistance to chromium and cadmium. This also highlighted the quality of nanoindentation measurements on thick dense layers where traditional nanoindentation excels. Nanoindentation was then performed on porous and non-porous MFI zeolite films with low-k (low dielectric constant) properties. These films were softer and much thinner than the ZSM-5 coatings resulting in significant substrate effects, evidenced by inflation of the measurements from the hard silicon substrate, during indentation. Such effects were avoided with the LiSAW technique on the same films where properties were readily extracted without complications. An alternative indentation analysis method was demonstrated to produce accurate mechanical measurements in line with the LiSAW results, but the non-traditional technique requires substantial computational intensity. Thus LiSAW was proven to be an accurate and efficient means of mechanical characterization for thin porous layers. The case for LiSAW was further supported by utilizing the technique on a porous nanostructured V2O5 electrode film. The surface roughness, on the same scale as indentation depths, created difficulty in obtaining consistent nanoindentation results. Since the film was too delicate for mechanical polishing, the nanoindentation results possessed a high level of uncertainty. It was demonstrated that the LiSAW technique could extract the mechanical properties from such layers without substrate effects and with higher accuracy than nanoindentation. The research in this dissertation directly demonstrates the areas where nanoindentation excels and the areas where it encounters difficulty. It is shown how the LiSAW technique can be an efficient alternative in the challenging areas through its dependence on bulk dispersive wave motion rather than localized deformation. Thus, LiSAW opens up many avenues towards the mechanical characterization of thin, porous, soft, or rough films. Nanoindentation remains an extremely useful technique for thin film characterization, especially with the alternative analysis adaptation. However, as films continue trending towards smaller length scales, more complex porous morphologies, and engineered nanoscale surfaces, LiSAW may well become an equally valuable and indispensable technique.

  9. Strain-free polished channel-cut crystal monochromators: a new approach and results

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kasman, Elina; Montgomery, Jonathan; Huang, XianRong

    The use of channel-cut crystal monochromators has been traditionally limited to applications that can tolerate the rough surface quality from wet etching without polishing. We have previously presented and discussed the motivation for producing channel cut crystals with strain-free polished surfaces [1]. Afterwards, we have undertaken an effort to design and implement an automated machine for polishing channel-cut crystals. The initial effort led to inefficient results. Since then, we conceptualized, designed, and implemented a new version of the channel-cut polishing machine, now called C-CHiRP (Channel-Cut High Resolution Polisher), also known as CCPM V2.0. The new machine design no longer utilizesmore » Figure-8 motion that mimics manual polishing. Instead, the polishing is achieved by a combination of rotary and linear functions of two coordinated motion systems. Here we present the new design of C-CHiRP, its capabilities and features. Multiple channel-cut crystals polished using the C-CHiRP have been deployed into several beamlines at the Advanced Photon Source (APS). We present the measurements of surface finish, flatness, as well as topography results obtained at 1-BM of APS, as compared with results typically achieved when polishing flat-surface monochromator crystals using conventional polishing processes. Limitations of the current machine design, capabilities and considerations for strain-free polishing of highly complex crystals are also discussed, together with an outlook for future developments and improvements.« less

  10. Between Polish Positivism and American Capitalism: The Educational Agents' Experiment in the Polish-American Community, 1889-1914

    ERIC Educational Resources Information Center

    Jaroszynska-Kirchmann, Anna D.

    2008-01-01

    "Ameryka-Echo" was one of the most popular Polish-language weeklies, published in the United States between 1889 and 1972. Its founder and owner, Antoni A. Paryski, consciously sought to transplant ideas of Polish Positivism to the Polish-American immigrant communities in the United States. Reading was a central concept of…

  11. Perceptions of and Attitudes towards Regional Varieties of Polish: Views from Two Polish Provinces

    ERIC Educational Resources Information Center

    Milobog, Magdalena; Garrett, Peter

    2011-01-01

    This paper reports a study of perceptions and attitudes relating to regional varieties of Polish. The methodology followed folk linguistic approaches to attitudes research. Respondents in two Polish provinces were asked to draw on a map of Poland where they thought the main regional varieties of Polish were spoken, and then to name and…

  12. Composite adaptive control of belt polishing force for aero-engine blade

    NASA Astrophysics Data System (ADS)

    Zhsao, Pengbing; Shi, Yaoyao

    2013-09-01

    The existing methods for blade polishing mainly focus on robot polishing and manual grinding. Due to the difficulty in high-precision control of the polishing force, the blade surface precision is very low in robot polishing, in particular, quality of the inlet and exhaust edges can not satisfy the processing requirements. Manual grinding has low efficiency, high labor intensity and unstable processing quality, moreover, the polished surface is vulnerable to burn, and the surface precision and integrity are difficult to ensure. In order to further improve the profile accuracy and surface quality, a pneumatic flexible polishing force-exerting mechanism is designed and a dual-mode switching composite adaptive control(DSCAC) strategy is proposed, which combines Bang-Bang control and model reference adaptive control based on fuzzy neural network(MRACFNN) together. By the mode decision-making mechanism, Bang-Bang control is used to track the control command signal quickly when the actual polishing force is far away from the target value, and MRACFNN is utilized in smaller error ranges to improve the system robustness and control precision. Based on the mathematical model of the force-exerting mechanism, simulation analysis is implemented on DSCAC. Simulation results show that the output polishing force can better track the given signal. Finally, the blade polishing experiments are carried out on the designed polishing equipment. Experimental results show that DSCAC can effectively mitigate the influence of gas compressibility, valve dead-time effect, valve nonlinear flow, cylinder friction, measurement noise and other interference on the control precision of polishing force, which has high control precision, strong robustness, strong anti-interference ability and other advantages compared with MRACFNN. The proposed research achieves high-precision control of the polishing force, effectively improves the blade machining precision and surface consistency, and significantly reduces the surface roughness.

  13. Effect of finishing/polishing techniques and time on surface roughness of esthetic restorative materials.

    PubMed

    Madhyastha, Prashanthi Sampath; Hegde, Shreya; Srikant, N; Kotian, Ravindra; Iyer, Srividhya Sriraman

    2017-01-01

    Surface roughness associated with improper finishing/polishing of restorations can result in plaque accumulation, gingival irritation, surface staining, and poor esthetic of restored teeth. The study aimed to evaluate the efficiency of various finishing and polishing systems and time using various procedures on surface roughness of some esthetic restorative materials. In this in vitro study, samples of two composite materials, compomer and glass ionomer cement (GIC) materials, were fabricated. Finishing and polishing were done immediately ( n = 40) and after 1 week ( n = 40) using four systems (diamond bur + soflex discs; diamond bur + Astropol polishing brush; tungsten carbide bur + soflex discs; tungsten carbide bur + Astropol polishing brush). Surface roughness was measured using surface profilometer. Data were statistically analyzed by t -test (for each material and time period) and one-way analysis of variance followed by Tukey's post hoc (for finishing and polishing systems) at a significant level of P < 0.05. Analysis of time period, irrespective of finishing and polishing system showed that Ra values were greater ( P < 0.05) in delayed polishing in GIC > Z100 > Filtek P90 > Dyract AP, suggesting immediate polishing is better. Among the materials, Filtek P90 had the least Ra values indicating the smoothest surface among all materials, followed by Z100, Dyract AP, and GIC. Comparison of polishing and finishing systems irrespective of materials showed that Ra values were lower ( P > 0.05) in diamond + Astropol combination whereas diamond + soflex had the greatest Ra values. It might be concluded that: (i) Filtek P90 showed least Ra values followed by < Z100 < Dyract < GIC; (ii) immediate (24 h) finishing/polishing of materials is better than delayed; and (iii) among all these polishing systems, diamond bur-Astropol and Astrobrush showed good surface finish.

  14. Gas Contamination In Plasma-Arc-Welded Aluminum

    NASA Technical Reports Server (NTRS)

    Mcclure, John C.; Torres, Martin R.; Gurevitch, Alan C.; Newman, Robert A.

    1992-01-01

    Document describes experimental investigation on visible and tactile effects of gaseous contaminants in variable-polarity plasma arc (VPPA) welding of 2219 T-87 aluminum alloy. Contaminant gases (nitrogen, methane, oxygen, and hydrogen) introduced in argon arc and in helium shield gas in various controlled concentrations. Report represents results of experiments in form of photographs of fronts, backs, polished cross sections, and etched cross sections of welds made with various contaminants at various concentrations. Provides detailed discussion of conditions under which welds made.

  15. Socioeconomic status and overweight prevalence in polish adolescents: the impact of single factors and a complex index of socioeconomic status in respect to age and sex.

    PubMed

    Kowalkowska, Joanna; Wadolowska, Lidia; Weronika Wuenstel, Justyna; Słowińska, Małgorzata Anna; Niedźwiedzka, Ewa

    2014-07-01

    The aim of this study was to analyze the association between overweight prevalence and socioeconomic status (SES) measured by complex SES index and single SES factors in Polish adolescents in respect to age and sex. This cross-sectional study was conducted in 2010-2011. A total of 1,176 adolescents aged 13.0-18.9 years were included. The respondents were students of junior-high and high schools from northern, eastern and central Poland. Quota sampling by sex and age was used. The SES was determined by: place of residence, self-declared economic situation, and parental education level. Respondents with low, average or high SES index (SESI) were identified. The level of overweight was assessed using Polish and international standards. The odds ratio (OR) for overweight prevalence in the oldest girls (aged 17.0-18.9 years) with high SESI was 0.34 (95%CI:0.13-0.92; P < 0.05) by Polish standards and 0.22 (95%CI:0.05-0.95; P < 0.05) by international standards, in comparison to the reference group (low SESI). In total girls who had mothers with higher education level, the OR adjusted for age was 0.44 (95%CI:0.21-0.90; P <0.05) by Polish standards and 0.35 (95%CI:0.15-0.81; P < 0.05) by international standards, in comparison to the reference group (maternal elementary education). The other single SES factors were not significant for overweight prevalence. The relationship between socioeconomic status and prevalence of overweight was related to sex and age. The high socioeconomic status strongly lowered the risk of overweight prevalence in the oldest girls, but not in boys, irrespective of age. Maternal education level lowered risk of overweight prevalence in girls.

  16. Socioeconomic Status and Overweight Prevalence in Polish Adolescents: The Impact of Single Factors and a Complex Index of Socioeconomic Status in Respect to Age and Sex

    PubMed Central

    KOWALKOWSKA, Joanna; WADOLOWSKA, Lidia; WERONIKA WUENSTEL, Justyna; SŁOWIŃSKA, Małgorzata Anna; NIEDŹWIEDZKA, Ewa

    2014-01-01

    Abstract Background The aim of this study was to analyze the association between overweight prevalence and socioeconomic status (SES) measured by complex SES index and single SES factors in Polish adolescents in respect to age and sex. Methods This cross-sectional study was conducted in 2010-2011. A total of 1,176 adolescents aged 13.0-18.9 years were included. The respondents were students of junior-high and high schools from northern, eastern and central Poland. Quota sampling by sex and age was used. The SES was determined by: place of residence, self-declared economic situation, and parental education level. Respondents with low, average or high SES index (SESI) were identified. The level of overweight was assessed using Polish and international standards. Results The odds ratio (OR) for overweight prevalence in the oldest girls (aged 17.0-18.9 years) with high SESI was 0.34 (95%CI:0.13-0.92; P < 0.05) by Polish standards and 0.22 (95%CI:0.05-0.95; P < 0.05) by international standards, in comparison to the reference group (low SESI). In total girls who had mothers with higher education level, the OR adjusted for age was 0.44 (95%CI:0.21-0.90; P <0.05) by Polish standards and 0.35 (95%CI:0.15-0.81; P < 0.05) by international standards, in comparison to the reference group (maternal elementary education). The other single SES factors were not significant for overweight prevalence Conclusions The relationship between socioeconomic status and prevalence of overweight was related to sex and age. The high socioeconomic status strongly lowered the risk of overweight prevalence in the oldest girls, but not in boys, irrespective of age. Maternal education level lowered risk of overweight prevalence in girls. PMID:25909059

  17. Calibration for Infrared Measurements of OH in Apatite

    NASA Astrophysics Data System (ADS)

    Wang, K. L.; Naab, F.; Zhang, Y.

    2010-12-01

    Apatite is a common accessory mineral, and OH in apatite can indicate the fluid conditions of crystal formation. Previously, water (OH) concentration in apatite has often been estimated through electron microprobe analyses combined with mineral stoichiometry. However, the detection limit, precision, and accuracy of this method are not high. In this work, we calibrated the infrared spectroscopy (IR) method for measurement of OH concentration in apatite by using elastic recoil detection (ERD) analysis to obtain the absolute OH concentration. Large apatite wafers were cut perpendicular to the c-axis of each crystal and doubly polished. ERD measurements were carried out in the Michigan Ion Beam Laboratory at the University of Michigan to determine the hydrogen concentration in each sample. Each ERD spectrum was fitted and a hydrogen standard was used to quantify the hydrogen concentrations. Polarized transmission IR was used on apatite sections that were cut parallel to the c-axis, and doubly polished. IR measurements were made for E-vector parallel to the c-axis. Because the OH peak is intense, very thin samples must be used to avoid absorbance saturation; the thinnest sample (corresponding to the highest OH content) used was 17 µm thick. Four different apatite crystals were successfully analyzed using both the IR and ERD methods. Two were from Durango, Mexico; one from Imilchil, High Atlas Mountains, Morocco; and one from an unknown locality, purchased online from gem dealers. The OH peak near 3550 cm-1 was a relatively simple peak in all four samples. Therefore peak height was used for the absorbance value, A. Using the Beer-Lambert Law, a calibration line was established (R2= 0.95, for IR aperture of 50 µm x 50 µm) where the weight % of H2O is 0.013 times A/d, where d is the thickness in mm. The detection limit of H2O concentration in apatite by IR approaches ppm level for 0.1 mm wafers, the precision is better than 1% relative (depending on H2O content), and the accuracy based on our calibration is 7% relative (2σ).

  18. Effects of delayed finishing/polishing on surface roughness, hardness and gloss of tooth-coloured restorative materials.

    PubMed

    Yazici, A Ruya; Tuncer, Duygu; Antonson, Sibel; Onen, Alev; Kilinc, Evren

    2010-01-01

    The aim of this study was to investigate the effect of delayed finishing/polishing on the surface roughness, hardness and gloss of tooth-coloured restorative materials. Four different tooth-coloured restoratives: a flowable resin composite- Tetric Flow, a hybrid resin composite- Venus, a nanohybrid resin composite- Grandio, and a polyacid modified resin composite- Dyract Extra were used. 30 specimens were made for each material and randomly assigned into three groups. The first group was finished/polished immediately and the second group was finished/polished after 24 hours. The remaining 10 specimens served as control. The surface roughness of each sample was recorded using a laser profilometer. Gloss measurements were performed using a small-area glossmeter. Vickers microhardness measurements were performed from three locations on each specimen surface under 100g load and 10s dwell time. Data for surface roughness and hardness were analyzed by Kruskal Wallis test and data for gloss were subjected to one-way ANOVA and Tukey test (P <.05). The smoothest surfaces were obtained under Mylar strip for all materials. While there were no significant differences in surface roughness of immediate and delayed finished/polished Dyract Extra samples, immediately finished/polished Venus and Grandio samples showed significantly higher roughness than the delayed polished samples (P <.05). In Tetric Flow samples, immediately finishing/polishing provided smoother surface than delayed finishing/polishing (P <.05). The highest gloss values were recorded under Mylar strip for all materials. While delayed finishing/polishing resulted in a significantly higher gloss compared to immediate finishing/polishing in Venus samples (P <.05), no differences were observed between delayed or immediate finishing/polishing for the other materials (P>.05). The lowest hardness values were found under Mylar strip. Delayed finishing/polishing significantly increased the hardness of all materials. The effect of delayed finishing/polishing on surface roughness, gloss and hardness appears to be material dependent.

  19. Surface properties of polyetheretherketone after different laboratory and chairside polishing protocols.

    PubMed

    Heimer, Sina; Schmidlin, Patrick R; Roos, Malgorzata; Stawarczyk, Bogna

    2017-03-01

    Polyetheretherketone (PEEK) can be used as a framework material for fixed dental prostheses. However, information about laboratory and chairside polishing methods is still scarce. The purpose of this in vitro study was to determine the effects of laboratory and chairside polishing methods on the surface roughness (SR) and surface free energy (SFE) of PEEK, an autopolymerizing poly(methyl methacrylate), and a veneering composite resin. For each of the 3 materials, 80 specimens were prepared (N=240) and divided into 7 polishing groups and 1 control group (n=10). The 7 groups were split into 4 laboratory protocols: polishing paste (Abraso), a second polishing paste (Opal L), silicone polisher (Ceragum), and diamond grinder (Diagen-Turbo grinder). The other 3 groups were chairside protocols: rainbow technique (Super-Snap kit), polishing paste (Prisma gloss), and a polishing system (Enhance finishing). Machine polishing with SiC P4000 served as the control treatment. The protocols' average SRs and SFEs were measured, and their surface topographies were evaluated with scanning electron microscopy (SEM). The logarithmically transformed data were analyzed using covariance analysis, 2-way and 1-way ANOVA, and partial correlation (α=.05). The polishing protocol exerted the highest influence on SR and SFE values (P<.001; SR: partial eta squared η P 2 =.970; SFE: η P 2 =.450), followed by material group (P<.001, SR: η P 2 =.319; SFE: η P 2 =.429). The interaction effect of the binary combinations of the 2 independent parameters (polishing protocol and material group) was also significant (P<.001, SR: η P 2 =.681; SFE: η P 2 =.365). Chairside methods presented lower SR values than laboratory methods, and specimens polished using the 2-body mode showed higher SR than did specimens polished using the 3-body mode. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  20. Publications - GMC 186 | Alaska Division of Geological & Geophysical

    Science.gov Websites

    DGGS GMC 186 Publication Details Title: Petrographic thin-section photographs of cuttings (14220'-14250 for more information. Bibliographic Reference Unknown, 1991, Petrographic thin-section photographs of

  1. Relationship between influence function accuracy and polishing quality in magnetorheological finishing

    NASA Astrophysics Data System (ADS)

    Schinhaerl, Markus; Schneider, Florian; Rascher, Rolf; Vogt, Christian; Sperber, Peter

    2010-10-01

    Magnetorheological finishing is a typical commercial application of a computer-controlled polishing process in the manufacturing of precision optical surfaces. Precise knowledge of the material removal characteristic of the polishing tool (influence function) is essential for controlling the material removal on the workpiece surface by the dwell time method. Results from the testing series with magnetorheological finishing have shown that a deviation of only 5% between the actual material removal characteristic of the polishing tool and that represented by the influence function caused a considerable reduction in the polishing quality. The paper discusses reasons for inaccuracies in the influence function and the effects on the polishing quality. The generic results of this research serve for the development of improved polishing strategies, and may be used in alternative applications of computer-controlled polishing processes that quantify the material removal characteristic by influence functions.

  2. [Mental health of Polish immigrants compared to that of the Polish and German populations].

    PubMed

    Morawa, Eva; Senf, Wolfgang; Erim, Yesim

    2013-01-01

    This survey examines the mental health of immigrants of Polish origin compared to samples from the Polish and German populations. In a sample of 513 subjects (261 persons with Polish migration background and 252 autochthone Poles) depression (BDI), anxiety (BAI), and somatic complaints (GBB-24) were measured. Immigrants of Polish origin showed a significantly higher level of anxiety as well as somatic complaints but only a tendency toward higher depressiveness than the German normvalue, but not than that of the native Poles. Female immigrants showed an overall higher number of symptoms in the three domains in question compared to German women and - except for depressiveness - also compared to male immigrants. Persons with a Polish migration background present levels of mental distress higher than the general German population, but similar to the population of their country of origin. Further research is needed to clarify the special structure of the mental morbidity in Polish immigrants.

  3. 7 CFR 29.2663 - Thin Leaf (C Group).

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 7 Agriculture 2 2014-01-01 2014-01-01 false Thin Leaf (C Group). 29.2663 Section 29.2663... REGULATIONS TOBACCO INSPECTION Standards Grades § 29.2663 Thin Leaf (C Group). This group consists of leaves that are thin in body. Grades Grade names and specifications C1L Choice Light-brown Thin Leaf. Thin...

  4. 7 CFR 29.2663 - Thin Leaf (C Group).

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 2 2011-01-01 2011-01-01 false Thin Leaf (C Group). 29.2663 Section 29.2663... REGULATIONS TOBACCO INSPECTION Standards Grades § 29.2663 Thin Leaf (C Group). This group consists of leaves that are thin in body. Grades Grade names and specifications C1L Choice Light-brown Thin Leaf. Thin...

  5. 7 CFR 29.2663 - Thin Leaf (C Group).

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 2 2010-01-01 2010-01-01 false Thin Leaf (C Group). 29.2663 Section 29.2663... REGULATIONS TOBACCO INSPECTION Standards Grades § 29.2663 Thin Leaf (C Group). This group consists of leaves that are thin in body. Grades Grade names and specifications C1L Choice Light-brown Thin Leaf. Thin...

  6. 7 CFR 29.2663 - Thin Leaf (C Group).

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 7 Agriculture 2 2013-01-01 2013-01-01 false Thin Leaf (C Group). 29.2663 Section 29.2663... REGULATIONS TOBACCO INSPECTION Standards Grades § 29.2663 Thin Leaf (C Group). This group consists of leaves that are thin in body. Grades Grade names and specifications C1L Choice Light-brown Thin Leaf. Thin...

  7. 7 CFR 29.2663 - Thin Leaf (C Group).

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 7 Agriculture 2 2012-01-01 2012-01-01 false Thin Leaf (C Group). 29.2663 Section 29.2663... REGULATIONS TOBACCO INSPECTION Standards Grades § 29.2663 Thin Leaf (C Group). This group consists of leaves that are thin in body. Grades Grade names and specifications C1L Choice Light-brown Thin Leaf. Thin...

  8. Low energy ion irradiation studies of fullerene C70 thin films - An emphasis on mapping the local structure modifications

    NASA Astrophysics Data System (ADS)

    Singhal, Rahul; Bhardwaj, Jyotsna; Vishnoi, Ritu; Aggarwal, S.; Sharma, Ganesh D.; Pivin, J. C.

    2018-06-01

    Metal matrix composites have a diverse range of applications. We have probed local structural modifications taking fullerene C70 as a model matrix material. In this study, thin films of fullerene C70 were grown on polished silicon and quartz substrates by resistive heating of fullerene C70. In order to understand local structural changes, these semi-crystalline films were irradiated with 120 keV N+ ions at different fluences ranging from 1 × 1013 to 3 × 1016 ions.cm-2. Microscopic analysis shows an increase in topological roughness up to a fluence of 1 × 1015 ions.cm-2 and then a decrease. The size of the particles decreases with increase in the fluence. Various spectroscopic analyses conducted on differently irradiated fullerene C70 films show that the bandgap decreases with the increase in the fluence which will increase the conductivity of the irradiated thin films. These results are proved by I-V measurements showing the decrease in the resistivity at higher fluences. Therefore, this characteristic trait makes fullerene C70 to be used as a prominent matrix component in the composites. Raman spectroscopic investigations reveal that C70 is completely transformed into amorphous carbon at a fluence of 3 × 1016 ions.cm-2. Different vibrational modes in FT-IR are also reported in the present work.

  9. Bendable X-ray Optics for High Resolution Imaging

    NASA Technical Reports Server (NTRS)

    Gubarev, M.; Ramsey, B.; Kilaru, K.; Atkins, C.; Broadway, D.

    2014-01-01

    Current state-of the-art for x-ray optics fabrication calls for either the polishing of massive substrates into high-angular-resolution mirrors or the replication of thin, lower-resolution, mirrors from perfectly figured mandrels. Future X-ray Missions will require a change in this optics fabrication paradigm in order to achieve sub-arcsecond resolution in light-weight optics. One possible approach to this is to start with perfectly flat, light-weight surface, bend it into a perfect cone, form the desired mirror figure by material deposition, and insert the resulting mirror into a telescope structure. Such an approach is currently being investigated at MSFC, and a status report will be presented detailing the results of finite element analyses, bending tests and differential deposition experiments.

  10. LLE review. Volume 61, Quarterly report, October--December 1994

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    1994-12-31

    This volume of the LLE review, covering the period of October--December 1994, contains articles on a diagnostic method employing krypton spectroscopy for measurement of temperature and shell-fuel mixing in high-temperature implosions; the first direct assessment of the ion-acoustic decay instability in a large-scale length, hot plasma; measurements of polarization mode dispersion and group-velocity walkaway in birefringent media using a frequency domain interferometer; an evaluation of the magnetic flux dynamics occurring in an optically triggered, thin-film superconducting switch; the effect of slurry fluid chemistry on particle size distribution during aqueous polishing of optical glass; and the influence of thermal and mechanicalmore » processing history in the preparation of well-ordered liquid crystal elastomer systems.« less

  11. Preparation methodologies and nano/microstructural evaluation of metal/semiconductor thin films.

    PubMed

    Chen, Zhiwen; Jiao, Zheng; Wu, Minghong; Shek, Chan-Hung; Wu, C M Lawrence; Lai, Joseph K L

    2012-01-01

    Metal/semiconductor thin films are a class of unique materials that are widespread technological applications, particularly in the field of microelectronic devices. Assessment strategies of fractal and tures are of fundamental importance in the development of nano/microdevices. This review presents the preparation methodologies and nano/microstructural evaluation of metal/semiconductor thin films including Au/Ge bilayer films and Pd-Ge alloy thin films, which show in the form of fractals and nanocrystals. Firstly, the extended version of Au/Ge thin films for the fractal crystallization of amorphous Ge and the formation of nanocrystals developed with improved micro- and nanostructured features are described in Section 2. Secondly, the nano/microstructural characteristics of Pd/Ge alloy thin films during annealing have been investigated in detail and described in Section 3. Finally, we will draw the conclusions from the present work as shown in Section 4. It is expected that the preparation methodologies developed and the knowledge of nano/microstructural evolution gained in metal/semiconductor thin films, including Au/Ge bilayer films and Pd-Ge alloy thin films, will provide an important fundamental basis underpinning further interdisciplinary research in these fields such as physics, chemistry, materials science, and nanoscience and nanotechnology, leading to promising exciting opportunities for future technological applications involving these thin films.

  12. Publications - GMC 357 | Alaska Division of Geological & Geophysical

    Science.gov Websites

    DGGS GMC 357 Publication Details Title: Thin Section and Scanning Electron Microscopy summary Laboratories, Inc., 2008, Thin Section and Scanning Electron Microscopy summary photographs from plugs taken

  13. Effect of the Polishing Procedures on Color Stability and Surface Roughness of Composite Resins

    PubMed Central

    Schmitt, Vera Lucia; Puppin-Rontani, Regina Maria; Naufel, Fabiana Scarparo; Nahsan, Flávia Pardo Salata; Alexandre Coelho Sinhoreti, Mário; Baseggio, Wagner

    2011-01-01

    Objectives. To evaluate the polishing procedures effect on color stability and surface roughness of composite resins. Methods. Specimens were distributed into 6 groups: G1: Filtek Supreme XT + PoGo; G2: Filtek Supreme XT + Sof-Lex; G3: Filtek Supreme XT + no polishing; G4: Amelogen + PoGo; G5: Amelogen + Sof-Lex.; G6: Amelogen + no polishing. Initial color values were evaluated using the CIELab scale. After polishing, surface roughness was evaluated and the specimens were stored in coffee solution at 37°C for 7 days. The final color measurement and roughness were determined. Results. Sof-Lex resulted in lower staining. Amelogen showed the highest roughness values than Filtek Supreme on baseline and final evaluations regardless of the polishing technique. Filtek Supreme polished with PoGo showed the lowest roughness values. All groups presented discoloration after storage in coffee solution, regardless of the polishing technique. Conclusion. Multiple-step polishing technique provided lower degree of discoloration for both composite resins. The final surface texture is material and technique dependent. PMID:21991483

  14. Publications - GMC 339 | Alaska Division of Geological & Geophysical

    Science.gov Websites

    petrography from petrographic thin sections of core (4759'-4894') Authors: Unknown Publication Date: Feb 2007 thin sections of core (4759'-4894'): Alaska Division of Geological & Geophysical Surveys Geologic

  15. Removing Silicon Monoxide From Nickel Mirrors

    NASA Technical Reports Server (NTRS)

    Zaniewski, John J.

    1987-01-01

    Combination of polishing tool and polishing mixture used to remove adherent fragments of silicon monoxide protective coatings from nickel/aluminum mirrors without altering shapes or harming polishes of mirror surfaces. Polishing technique developed to prepare stained mirrors for recoating to restore high reflectance.

  16. Deterministic Computer-Controlled Polishing Process for High-Energy X-Ray Optics

    NASA Technical Reports Server (NTRS)

    Khan, Gufran S.; Gubarev, Mikhail; Speegle, Chet; Ramsey, Brian

    2010-01-01

    A deterministic computer-controlled polishing process for large X-ray mirror mandrels is presented. Using tool s influence function and material removal rate extracted from polishing experiments, design considerations of polishing laps and optimized operating parameters are discussed

  17. The Impact of a First-Generation Immigrant Environment on the Heritage Language: Productive Vocabularies of Polish Toddlers Living in the UK and Ireland

    ERIC Educational Resources Information Center

    Miekisz, Aneta; Haman, Ewa; Luniewska, Magdalena; Kus, Katarzyna; O'Toole, Ciara; Katsos, Napoleon

    2017-01-01

    The expressive lexical skills of 53 Polish bilinguals aged 24-36 months living in the UK and Ireland were assessed using Polish and British English adaptations of the MacArthur-Bates Communicative Development Inventories. Polish vocabulary scores were compared to those of 53 Polish monolinguals matched for age, gender and parental education. The…

  18. Cancer morbidity among polishers.

    PubMed Central

    Järvholm, B; Thiringer, G; Axelson, O

    1982-01-01

    The mortality pattern among 86 men was determined to investigate the possible hazards of polishing steel. The men had polished steel with polishing paste for at least five years. The polishing pastes had contained tallow, beeswax, carnauba wax, alundum, carborundum, ferric oxide, and chalk. A total of 18 men had died compared with 13.3 expected. Four had died of stomach cancer compared with 0.44 expected (p less than 0.005). The mortality for other causes of death was not increased. The study does not permit any definite conclusion but indicates a possible cancer hazard among polishers. PMID:7066237

  19. Zerodur polishing process for high surface quality and high efficiency

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tesar, A.; Fuchs, B.

    1992-08-01

    Zerodur is a glass-ceramic composite importance in applications where temperature instabilities influence optical and mechanical performance, such as in earthbound and spaceborne telescope mirror substrates. Polished Zerodur surfaces of high quality have been required for laser gyro mirrors. Polished surface quality of substrates affects performance of high reflection coatings. Thus, the interest in improving Zerodur polished surface quality has become more general. Beyond eliminating subsurface damage, high quality surfaces are produced by reducing the amount of hydrated material redeposited on the surface during polishing. With the proper control of polishing parameters, such surfaces exhibit roughnesses of

  20. Bacterial carriage on the fingernails of OR nurses.

    PubMed

    Wynd, C A; Samstag, D E; Lapp, A M

    1994-11-01

    This study provides statistically significant data that demonstrate that chipped fingernail polish or fingernail polish worn longer than four days fosters increased numbers of bacteria on the fingernails of OR nurses after surgical hand scrubs. There were no significant correlations between fingernail length and the numbers of bacterial colonies on the fingernails of the study groups tested after performing a standard surgical hand scrub. A convenience sample of 102 perioperative nurses with either freshly polished fingernails; chipped fingernail polish; or natural, polish-free fingernails participated. The data suggest OR nurses can wear fresh fingernail polish on healthy fingernails without risking increased bacterial counts.

  1. Magnetorheological elastic super-smooth finishing for high-efficiency manufacturing of ultraviolet laser resistant optics

    NASA Astrophysics Data System (ADS)

    Shi, Feng; Shu, Yong; Dai, Yifan; Peng, Xiaoqiang; Li, Shengyi

    2013-07-01

    Based on the elastic-plastic deformation theory, status between abrasives and workpiece in magnetorheological finishing (MRF) process and the feasibility of elastic polishing are analyzed. The relationship among material removal mechanism and particle force, removal efficiency, and surface topography are revealed through a set of experiments. The chemical dominant elastic super-smooth polishing can be fulfilled by changing the components of magnetorheological (MR) fluid and optimizing polishing parameters. The MR elastic super-smooth finishing technology can be applied in polishing high-power laser-irradiated components with high efficiency, high accuracy, low damage, and high laser-induced damage threshold (LIDT). A 430×430×10 mm fused silica (FS) optic window is polished and surface error is improved from 538.241 nm [peak to valley (PV)], 96.376 nm (rms) to 76.372 nm (PV), 8.295 nm (rms) after 51.6 h rough polishing, 42.6 h fine polishing, and 54.6 h super-smooth polishing. A 50×50×10 mm sample is polished with exactly the same parameters. The roughness is improved from 1.793 nm [roughness average (Ra)] to 0.167 nm (Ra) and LIDT is improved from 9.77 to 19.2 J/cm2 after MRF elastic polishing.

  2. Multiwavelength digital holography for polishing tool shape measurement

    NASA Astrophysics Data System (ADS)

    Lédl, Vít.; Psota, Pavel; Václavík, Jan; Doleček, Roman; Vojtíšek, Petr

    2013-09-01

    Classical mechano-chemical polishing is still a valuable technique, which gives unbeatable results for some types of optical surfaces. For example, optics for high power lasers requires minimized subsurface damage, very high cosmetic quality, and low mid spatial frequency error. One can hardly achieve this with use of subaperture polishing. The shape of the polishing tool plays a crucial role in achieving the required form of the optical surface. Often the shape of the polishing tool or pad is not known precisely enough during the manufacturing process. The tool shape is usually premachined and later is changed during the polishing procedure. An experienced worker could estimate the shape of the tool indirectly from the shape of the polished element, and that is why he can achieve the required shape in few reasonably long iterative steps. Therefore the lack of the exact tool shape knowledge is tolerated. Sometimes, this indirect method is not feasible even if small parts are considered. Moreover, if processes on machines like planetary (continuous) polishers are considered, the incorrect shape of the polishing pad could extend the polishing times extremely. Every iteration step takes hours. Even worse, polished piece could be wasted if the pad has a poor shape. The ability of the tool shape determination would be very valuable in those types of lengthy processes. It was our primary motivation to develop a contactless measurement method for large diffusive surfaces and demonstrate its usability. The proposed method is based on application of multiwavelength digital holographic interferometry with phase shift.

  3. Polishing parameter optimization for end-surface of chalcogenide glass fiber connector

    NASA Astrophysics Data System (ADS)

    Guo, Fangxia; Dai, Shixun; Tang, Junzhou; Wang, Xunsi; Li, Xing; Xu, Yinsheng; Wu, Yuehao; Liu, Zijun

    2017-11-01

    We have investigated the optimization parameters for polishing end-surface of chalcogenide glass fiber connector in the paper. Six SiC abrasive particles of different sizes were used to polish the fiber in order of size from large to small. We analyzed the effects of polishing parameters such as particle sizes, grinding speeds and polishing durations on the quality of the fiber end surface and determined the optimized polishing parameters. We found that, high-quality fiber end surface can be achieved using only three different SiC abrasives. The surface roughness of the final ChG fiber end surface is about 48 nm without any scratches, spots and cracks. Such polishing processes could reduce the average insertion loss of the connector to about 3.4 dB.

  4. Surface Roughness and Gloss of Actual Composites as Polished With Different Polishing Systems.

    PubMed

    Rodrigues-Junior, S A; Chemin, P; Piaia, P P; Ferracane, J L

    2015-01-01

    This in vitro study evaluated the effect of polishing with different polishing systems on the surface roughness and gloss of commercial composites. One hundred disk-shaped specimens (10 mm in diameter × 2 mm thick) were made with Filtek P-90, Filtek Z350 XT, Opallis, and Grandio. The specimens were manually finished with #400 sandpaper and polished by a single operator using three multistep systems (Superfix, Diamond Pro, and Sof-lex), one two-step system (Polidores DFL), and one one-step system (Enhance), following the manufacturer's instructions. The average surface roughness (μm) was measured with a surface profilometer (TR 200 Surface Roughness Tester), and gloss was measured using a small-area glossmeter (Novo-Curve, Rhopoint Instrumentation, East Sussex, UK). Data were analyzed by two-way analysis of variance and Tukey's test (α=0.05). Statistically significant differences in surface roughness were identified by varying the polishing systems (p<0.0001) and by the interaction between polishing system and composite (p<0.0001). Pairwise comparisons revealed higher surface roughness for Grandio when polished with Sof-Lex and Filtek Z250 and Opallis when polished with Enhance. Gloss was influenced by the composites (p<0.0001), the polishing systems (p<0.0001), and the interaction between them (p<0.0001). The one-step system, Enhance, produced the lowest gloss for all composites. Surface roughness and gloss were affected by composites and polishing systems. The interaction between both also influenced these surface characteristics, meaning that a single polishing system will not behave similarly for all composites. The multistep systems produced higher gloss, while the one-step system produced the highest surface roughness and the lowest gloss of all.

  5. Adjusting dental ceramics: An in vitro evaluation of the ability of various ceramic polishing kits to mimic glazed dental ceramic surface.

    PubMed

    Steiner, René; Beier, Ulrike S; Heiss-Kisielewsky, Irene; Engelmeier, Robert; Dumfahrt, Herbert; Dhima, Matilda

    2015-06-01

    During the insertion appointment, the practitioner is often faced with the need to adjust ceramic surfaces to fit a restoration to the adjacent or opposing dentition and soft tissues. The purpose of this study was to assess the ceramic surface smoothness achieved with various commercially available ceramic polishing kits on different commonly used ceramic systems. The reliability of the cost of a polishing kit as an indicator of improved surface smoothness was assessed. A total of 350 ceramic surfaces representing 5 commonly available ceramic systems (IPS Empress Esthetic, IPS e.max Press, Cergo Kiss, Vita PM 9, Imagine PressX) were treated with 5 types of ceramic polishing systems (Cerapreshine, 94006C, Ceramiste, Optrafine, Zenostar) by following the manufacturers' guidelines. The surface roughness was measured with a profilometer (Taylor Hobson; Precision Taylor Hobson Ltd). The effects of ceramic systems and polishing kits of interest on surface roughness were analyzed by 2-way ANOVA, paired t test, and Bonferroni corrected significance level. The ceramic systems and polishing kits statistically affected surface roughness (P<.001).The polishing kit Zenostar on IPS e.max Press created the smoothest ceramic surface. No correlation could be established between the high cost of the polishing kit and low surface roughness. None of the commonly used ceramic polishing kits could create a surface smoother than that of glazed ceramic (P<.001). The inclusion of a diamond polishing paste step is recommended to improve surface smoothness (P<.001). The cost of ceramic polishing kits is not recommended as a reliable indicator of better performance of ceramic polishing kits (P>.30). Copyright © 2015 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  6. Publications - GMC 399 | Alaska Division of Geological & Geophysical

    Science.gov Websites

    DGGS GMC 399 Publication Details Title: Thin section photomicrographs and descriptions for the Ikpikpuk Boyer, D., 2012, Thin section photomicrographs and descriptions for the Ikpikpuk #1, Inigok #1, J.W

  7. Wear resistant pavement study.

    DOT National Transportation Integrated Search

    2009-01-01

    This report documents the construction of three special pavement test sections on I-90 east of Spokane, Washington. The test sections included ultra-thin and thin whitetopping, Modified Class D open graded asphalt concrete, and micro/macro surfacing ...

  8. Examination of the polished surface character of fused silica.

    PubMed

    Tesar, A A; Fuchs, B A; Hed, P P

    1992-12-01

    Investigation of the surface character of fused silica polished with various compounds dispersed in water identified pH 4 as the optimum condition for high quality. Analyses support the conclusion that at this pH redeposition of hydrated material onto the surface during polishing is limited. Comparative polishing results for Zerodur are included. Improvement of the laser-damage threshold of a coating on the pH 4 polished fused silica is suggested.

  9. Examination of the polished surface character of fused silica

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tesar, A.A.; Fuchs, B.A.; Hed, P.P.

    1992-12-01

    Investigation of the surface character of fused silica polished with various compounds dispersed in water identified pH 4 as the optimum condition for high quality. Analyses support the conclusion that at this pH redeposition of hydrated material onto the surface during polishing is limited. Comparative polishing results for Zerodur are included. Improvement of the laser-damage threshold of a coating on the pH 4 polished fused silica is suggested.

  10. The effects of different polishing techniques on the staining resistance of CAD/CAM resin-ceramics

    PubMed Central

    Demirci, Tevfik; Demirci, Gamze; Sagsoz, Nurdan Polat; Yildiz, Mehmet

    2016-01-01

    PURPOSE The purposes of this study were to evaluate the staining resistance of CAD/CAM resin-ceramics polished with different techniques and to determine the effectiveness of the polishing techniques on resin-ceramics, comparing it with that of a glazed glass-ceramic. MATERIALS AND METHODS Four different CAD/CAM ceramics (feldspathic ceramic: C-CEREC Blocs, (SIRONA) and three resin-ceramics: L-Lava Ultimate, (3M ESPE), E-Enamic, (VITA) and CS-CeraSmart, (GC)) and one light cure composite resin: ME-Clearfil Majesty Esthetic (Kuraray) were used. Only C samples were glazed (gl). Other restorations were divided into four groups according to the polishing technique: nonpolished control group (c), a group polished with light cure liquid polish (Biscover LV BISCO) (bb), a group polished with ceramic polishing kit (Diapol, EVE) (cd), and a group polished with composite polishing kit (Clearfil Twist Dia, Kuraray) (kc). Glazed C samples and the polished samples were further divided into four subgroups and immersed into different solutions: distilled water, tea, coffee, and fermented black carrot juice. Eight samples (8 × 8 × 1 mm) were prepared for each subgroup. According to CIELab system, four color measurements were made: before immersion, immersion after 1 day, after 1 week, and after 1 month. Data were analyzed with repeated measures of ANOVA (α=.05). RESULTS The highest staining resistance was found in gl samples. There was no difference among gl, kc and cd (P>.05). Staining resistance of gl was significantly higher than that of bb (P<.05). Staining resistances of E and CS were significantly higher than those of L and ME (P<.05). CONCLUSION Ceramic and composite polishing kits can be used for resin ceramics as a counterpart of glazing procedure used for full ceramic materials. Liquid polish has limited indications for resin ceramics. PMID:28018558

  11. Influence of polishing on surface roughness following toothbrushing wear of composite resins.

    PubMed

    Dalla-Vecchia, Karine Battestin; Taborda, Talita Damas; Stona, Deborah; Pressi, Heloísa; Burnett Júnior, Luiz Henrique; Rodrigues-Junior, Sinval Adalberto

    2017-01-01

    This study aimed to evaluate the influence of different polishing systems on the surface roughness of composite resins following procedures to simulate the effects of toothbrushing over time. Four currently available commercial composites were used to make 128 cylindrical specimens. The specimens were randomly allocated to polishing with a 1-step polisher or 1 of 3 multistep polishers (n = 8 per group). The baseline surface roughness was measured, and the specimens were submitted to 5000, 10,000, and 20,000 brushing cycles to represent toothbrushing throughout 6, 12, and 24 months, respectively. Results showed that surface roughness was influenced by the type of composite and polishing system and was not influenced by the simulated toothbrushing time. However, the surface roughness, as challenged by toothbrushing wear, was affected by the interaction among the composite, the polisher, and the toothbrushing time. The 1-step polisher produced the highest surface roughness and influenced toothbrushing wear resistance of some composites.

  12. A petrographic thin sectioning technique for evaluating composite materials

    NASA Technical Reports Server (NTRS)

    Parker, D. S.; Yee, A. F.

    1989-01-01

    Petrographic thin sectioning by a low-speed diamond saw has been used in conjunction with transmission polarized light microscopy for the characterization of the microstructure and deformation mechanisms of a variety of polymer systems. It has proven possible by these means to study three types of thermoplastic matrices for composite applications: PEEK, BPA-based polycarbonate (PC), and a rubber-modified PC. The reinforcing fibers for these matrices were in all cases AS4 carbon fibers, unidirectionally arrayed. Superior analyzability of matrix morphology and subsurface fracture processes is achieved by thin sectioning.

  13. Effect of polishing instruments and polishing regimens on surface topography and phase transformation of monolithic zirconia: An evaluation with XPS and XRD analysis.

    PubMed

    Al-Haj Husain, Nadin; Camilleri, Josette; Özcan, Mutlu

    2016-12-01

    Polishing procedures might alter monolithic zirconia (MZ) surface resulting in phase changes that can be deleterious for clinical performance and antagonist tooth wear. This study investigated the topographical features and phase transformation in MZ after polishing with different regimens simulating the clinical workflow. ​ MZ specimens (Katana Zirconia HT, Kuraray-Noritake) (12×12×1.8 mm(3)) were grinded and polished using one of the five systems assessed: BG: Silicone carbide polishers (Brownie, Greenie, Super Greenie); CG: Diamond impregnated ceramic polisher kit (Ceragloss); EV: Synthetically bonded grinder interspersed with diamond (EVE Kit); SL: Urethane coated paper with aluminium oxide grits (Soflex Finishing and Polishing System Kit) and DB: Diamond bur (8 µm). Polished specimens were initially roughened with 220 µm diamond burs (Grinding Bur-GB) (10 s, 160.000160,000 rpm) and considered for baseline measurements. Polishing regimens were performed for 10 s using a slow-speed hand piece under water-cooling except for SL, in a custom made device (750 g; 5000 and 75,000 rpm). Surface roughnesses, phase changes (XRD) were assessed, surface characterization was performed (SEM, EDS). The highest roughness was obtained with the EV system (1.11 µm) compared to those of other systems (0.13-0.4 µm) (pθ and minor peak at 34.94°2θ. While GB, CG, EV, SL and DB exhibited a peak shift to the left, BG demonstrated a right peak shift on the 2θ scale. Monoclinic phase change was not noted in any of the groups. All polishing methods, except BG, exhibited a peak shift towards the lower angles of the 2-theta scale. Since the peak shifts were in the order of fractions of an angle they are attributed to stress formation rather than a phase change in the material. Thus, all polishing systems tested may not be detrimental for the phase transformation of MZ. EV system resulted in the highest roughness and none of the polishing regimens restored the polishability to the baseline level. Copyright © 2016 Elsevier Ltd. All rights reserved.

  14. Characterisation of Ga-coated and Ga-brazed aluminium

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ferchaud, E.; Christien, F., E-mail: frederic.christien@univ-nantes.fr; Barnier, V.

    This work is devoted to the brazing of aluminium using liquid gallium. Gallium was deposited on aluminium samples at {approx} 50 Degree-Sign C using a liquid gallium 'polishing' technique. Brazing was undertaken for 30 min at 500 Degree-Sign C in air. EDS (Energy Dispersive X-ray Spectroscopy) and AES (Auger Electron Spectroscopy) characterisation of Ga-coated samples has shown that the Ga surface layer thickness is of ten (or a few tens of) nanometres. Furthermore, aluminium oxide layer (Al{sub 2}O{sub 3}) was shown to be 'descaled' during Ga deposition, which ensures good conditions for further brazing. Cross-section examination of Ga-coated samples showsmore » that liquid gallium penetrates into the aluminium grain boundaries during deposition. The thickness of the grain boundary gallium film was measured using an original EDS technique and is found to be of a few tens of nanometres. The depth of gallium grain boundary penetration is about 300 {mu}m at the deposition temperature. The fracture stress of the brazed joints was measured from tensile tests and was determined to be 33 MPa. Cross-section examination of brazed joints shows that gallium has fully dissolved into the bulk and that the joint is really autogenous. - Highlights: Black-Right-Pointing-Pointer Aluminium can be brazed using liquid gallium deposited by a 'polishing' technique. Black-Right-Pointing-Pointer The aluminium oxide layer is 'descaled' during liquid Ga 'polishing' deposition. Black-Right-Pointing-Pointer EDS can be used for determination of surface and grain boundary Ga film thickness. Black-Right-Pointing-Pointer The surface and grain boundary Ga film thickness is of a few tens of nm. Black-Right-Pointing-Pointer Surface and grain boundary gallium dissolves in the bulk during brazing.« less

  15. A Cross-Sectional Study on Selected Correlates of High risk Sexual Behavior in Polish Migrants Resident in the United Kingdom

    PubMed Central

    Ganczak, Maria; Czubińska, Grażyna; Korzeń, Marcin; Szych, Zbigniew

    2017-01-01

    Objective: To assess the correlates of the high risk sexual behaviors of Polish migrants in the United Kingdom (UK) after 2004, and to compare such behaviors before/after immigration. Methods: In 2013, a cross-sectional study was conducted through the use of a Computer-assisted web interviewing surveying technique with the use of a self-administered questionnaire. Results: Among 408 respondents (56.9% women), with a median age of 32 years, significantly more admitted to having unprotected sexual contact with a casual partner while in the UK (p < 0.0001) than while in Poland; more were engaged in sex after the use of recreational drugs and alcohol (p < 0.0001 and p = 0.001 respectively). Being a male was associated with greater odds of unprotected sex, sex after the use of alcohol, and having multiple partners. Being single and having only been a resident for a short time in the UK, presenting a lower self-esteem, were predictors of unprotected sex. A total of 19.6% of the respondents admitted to having been tested while in Poland, a lower (p < 0.0001) frequency than while in the UK (49.5%); this referred to both genders; 1.2% (95% CI: 0.79–2.83%) reported that they were HIV positive. Conclusions: Migration can create a vulnerability to STIs, especially for single male migrants with low self-esteem, staying in the UK for less than two years. The results point to strengthening strategies which help reduce high risk sexual behavior among Polish migrants, and to introduce interventions to promote an awareness of HIV sero-status. PMID:28420115

  16. A Cross-Sectional Study on Selected Correlates of High risk Sexual Behavior in Polish Migrants Resident in the United Kingdom.

    PubMed

    Ganczak, Maria; Czubińska, Grażyna; Korzeń, Marcin; Szych, Zbigniew

    2017-04-14

    Objective : To assess the correlates of the high risk sexual behaviors of Polish migrants in the United Kingdom (UK) after 2004, and to compare such behaviors before/after immigration. Methods : In 2013, a cross-sectional study was conducted through the use of a Computer-assisted web interviewing surveying technique with the use of a self-administered questionnaire. Results : Among 408 respondents (56.9% women), with a median age of 32 years, significantly more admitted to having unprotected sexual contact with a casual partner while in the UK ( p < 0.0001) than while in Poland; more were engaged in sex after the use of recreational drugs and alcohol ( p < 0.0001 and p = 0.001 respectively). Being a male was associated with greater odds of unprotected sex, sex after the use of alcohol, and having multiple partners. Being single and having only been a resident for a short time in the UK, presenting a lower self-esteem, were predictors of unprotected sex. A total of 19.6% of the respondents admitted to having been tested while in Poland, a lower ( p < 0.0001) frequency than while in the UK (49.5%); this referred to both genders; 1.2% (95% CI: 0.79-2.83%) reported that they were HIV positive. Conclusions : Migration can create a vulnerability to STIs, especially for single male migrants with low self-esteem, staying in the UK for less than two years. The results point to strengthening strategies which help reduce high risk sexual behavior among Polish migrants, and to introduce interventions to promote an awareness of HIV sero-status.

  17. Pseudo-random tool paths for CNC sub-aperture polishing and other applications.

    PubMed

    Dunn, Christina R; Walker, David D

    2008-11-10

    In this paper we first contrast classical and CNC polishing techniques in regard to the repetitiveness of the machine motions. We then present a pseudo-random tool path for use with CNC sub-aperture polishing techniques and report polishing results from equivalent random and raster tool-paths. The random tool-path used - the unicursal random tool-path - employs a random seed to generate a pattern which never crosses itself. Because of this property, this tool-path is directly compatible with dwell time maps for corrective polishing. The tool-path can be used to polish any continuous area of any boundary shape, including surfaces with interior perforations.

  18. Wear characteristics of polished and glazed lithium disilicate ceramics opposed to three ceramic materials.

    PubMed

    Saiki, Osamu; Koizumi, Hiroyasu; Akazawa, Nobutaka; Kodaira, Akihisa; Okamura, Kentaro; Matsumura, Hideo

    2016-01-01

    This study compared the wear characteristics of a heat-pressed lithium disilicate ceramic material opposed to feldspathic porcelain, a lithium disilicate glass ceramic, and zirconia materials. Ceramic plate specimens were prepared from feldspathic porcelain (EX-3 nA1B), lithium disilicate glass ceramics (e.max CAD MO1/C14), and zirconia (Katana KT 10) and then ground or polished. Rounded rod specimens were fabricated from heat-pressed lithium disilicate glass ceramic (e.max press LT A3) and then glazed or polished. A sliding wear testing apparatus was used for wear testing. Wear of glazed rods was greater than that of polished rods when they were abraded with ground zirconia, ground porcelain, polished porcelain, or polished lithium disilicate ceramics. For both glazed and polished rods, wear was greater when the rods were abraded with ground plates. The findings indicate that application of a polished surface rather than a glazed surface is recommended for single restorations made of heat-pressed lithium disilicate material. In addition, care must be taken when polishing opposing materials, especially those used in occlusal contact areas. (J Oral Sci 58, 117-123, 2016).

  19. Reasons of different colors in the ignimbrite lithology: micro-XRF and confocal Raman spectrometry method.

    PubMed

    Koralay, Tamer; Kadioglu, Yusuf Kagan

    2008-03-01

    Medium to large volume ignimbrites usually show vertical changes in terms of color, mineral components, texture and geochemistry. Determination of vertical changes in single extensive ignimbrite flow unit is difficult and requires careful studies. Color changes in ignimbrite flow units are very important for earth scientists. This may cause to identify the same ignimbrite series with different definition. Incesu ignimbrite has a wide distribution in the Central Anatolian Volcanic Province (CAVP). It is classified into three levels as lower, middle and upper according to color and welding degree. There is a sharp contact between the lower and middle level. The lower level is dark brown to black in color and the middle level has pinkish red to red color. The present paper focuses on the investigation of color changes between the ignimbrite levels by using micro-XRF and confocal Raman spectrometry. Micro-XRF and Raman spectrometry studies were performed on the polished thin sections of the lower and middle levels with different compositions. These differences were because of the compositional changes of K and slightly Fe elements distribution within the matrix. The dark brown to black color of the lower level was related to the high concentration of the K and Fe relatively to the middle level. Confocal Raman spectrometry investigations exhibited the matrix of the lower level mainly composed of anorthoclase, supporting the results of the micro-XRF.

  20. Polish Higher Education: Intersectoral Distinctiveness

    ERIC Educational Resources Information Center

    Musial, Joanna

    2014-01-01

    This study analyzes degrees of differences between the private and public sectors of Polish higher education. It finds them to be strong: Polish private institutions function very differently from Polish public institutions and these differences correspond with those found in the literature on higher education elsewhere in the world. Polish…

  1. The advancement of the high precision stress polishing

    NASA Astrophysics Data System (ADS)

    Li, Chaoqiang; Lei, Baiping; Han, Yu

    2016-10-01

    The stress polishing is a kind of large-diameter aspheric machining technology with high efficiency. This paper focuses on the principle, application in the processing of large aspheric mirror, and the domestic and foreign research status of stress polishing, aimed at the problem of insufficient precision of mirror surface deformation calculated by some traditional theories and the problem that the output precision and stability of the support device in stress polishing cannot meet the requirements. The improvement methods from these three aspects are put forward, the characterization method of mirror's elastic deformation in stress polishing, the deformation theory of influence function and the calculation of correction force, the design of actuator's mechanical structure. These improve the precision of stress polishing and provide theoretical basis for the further application of stress polishing in large-diameter aspheric machining.

  2. Surface geometry of three packable and one hybrid composite after polishing.

    PubMed

    Jung, Martin; Bruegger, Hilka; Klimek, Joachim

    2003-01-01

    This study evaluated the surface quality of four composite materials after polishing with six different polishing techniques. Eighty specimens were made using three packable composites (Definite/Degussa, SureFil/ Dentsply and Solitaire/Heraeus-Kulzer) and one hybrid composite (Herculite XRV/Kerr). Five specimens of each material were polished using flexible Sof-Lex discs. The remaining 75 specimens of each composite were prepared using three finishing protocols: a single 30 microm diamond (n = 25), two finishing diamonds (30/20 microm; n = 25) and a 30 microm diamond followed by a tungsten carbide finishing bur (n = 25). Final polishing of each of the three finishing groups was accomplished with SuperBuff, Diafix-oral, OneGloss, Astropol and HaWe Composite Polishers (n = 5, each). Surface roughness was evaluated quantitatively by laser-stylus profilometry. Average roughness (R(a)) was calculated; statistical analysis of the data was performed with two-way ANOVA and Scheffé post-hoc tests. The polished surfaces were examined qualitatively by SEM. The results showed significant effects on surface roughness from the different composites (p = 0.011) and polishing systems (p < 0.001). After polishing, the Solitaire surfaces (R(a) = 0.72 microm) were smoother than Definite (R(a) = 0.87 microm) and SureFil (R(a) = 0.89 microm) and significantly smoother than Herculite (R(a) = 0.92 microm; p = 0.011). Three of the polishing methods (SuperBuff, Diafix-oral and Astropol) achieved lower R(a)-values than Sof-Lex discs. The polishing quality of the one-step systems SuperBuff and Diafix-oral was strongly affected by the initial finishing protocol.

  3. The effect of nail polish and acrylic nails on pulse oximetry reading using the Lifebox oximeter in Nigeria.

    PubMed

    Desalu, I; Diakparomre, O I; Salami, A O; Abiola, A O

    2013-12-01

    AIMS AND OBJECTIVES - Pulse oximetry is mandatory during anaesthesia, sedation and transfer of critically ill patients. The effect of nail polish and acrylic nails on the accuracy of saturation reading is inconsistent. The Lifebox pulse oximeter is reliable and recommended for low and middle income countries. We investigated its accuracy in the presence of 4 nail colours and acrylic nails SUBJECTS AND METHODS Fifty non-smoking volunteers had their fingers numbered from right to left (little finger of right hand =1 and little finger of left hand =10). Alternate fingers were nails painted with clear, red, brown and black nail polish and the 5th finger had acrylic nail applied. The corresponding finger on the other hand acted as control. The oxygen saturation was determined using the Lifebox pulse oximeter. Results All fingers (100%) with clear nail polish, red nail polish and acrylic nails recorded a saturation value. Each of the mean saturation value for clear nail polish, red nail polish and acrylic nails was not significantly different from the control mean (p= 0.378, 0.427 and 0.921). Only 12% and 64% of nails polished black and brown respectively recorded a saturation value. The mean SpO- for black and brown polish were significantly different from their control mean (p<0.001). CONCLUSION Black and brown polish resulted in a significant decrease in SpO with the Lifebox oximeter. Dark coloured nail polish should be removed prior to SpO2 determination to ensure that accurate readings can be obtained.

  4. Computer-Controlled Cylindrical Polishing Process for Large X-Ray Mirror Mandrels

    NASA Technical Reports Server (NTRS)

    Khan, Gufran S.; Gubarev, Mikhail; Speegle, Chet; Ramsey, Brian

    2010-01-01

    We are developing high-energy grazing incidence shell optics for hard-x-ray telescopes. The resolution of a mirror shells depends on the quality of cylindrical mandrel from which they are being replicated. Mid-spatial-frequency axial figure error is a dominant contributor in the error budget of the mandrel. This paper presents our efforts to develop a deterministic cylindrical polishing process in order to keep the mid-spatial-frequency axial figure errors to a minimum. Simulation software is developed to model the residual surface figure errors of a mandrel due to the polishing process parameters and the tools used, as well as to compute the optical performance of the optics. The study carried out using the developed software was focused on establishing a relationship between the polishing process parameters and the mid-spatial-frequency error generation. The process parameters modeled are the speeds of the lap and the mandrel, the tool s influence function, the contour path (dwell) of the tools, their shape and the distribution of the tools on the polishing lap. Using the inputs from the mathematical model, a mandrel having conical approximated Wolter-1 geometry, has been polished on a newly developed computer-controlled cylindrical polishing machine. The preliminary results of a series of polishing experiments demonstrate a qualitative agreement with the developed model. We report our first experimental results and discuss plans for further improvements in the polishing process. The ability to simulate the polishing process is critical to optimize the polishing process, improve the mandrel quality and significantly reduce the cost of mandrel production

  5. Polishing mechanism of light-initiated dental composite: Geometric optics approach.

    PubMed

    Chiang, Yu-Chih; Lai, Eddie Hsiang-Hua; Kunzelmann, Karl-Heinz

    2016-12-01

    For light-initiated dental hybrid composites, reinforcing particles are much stiffer than the matrix, which makes the surface rugged after inadequate polish and favors bacterial adhesion and biofilm redevelopment. The aim of the study was to investigate the polishing mechanism via the geometric optics approach. We defined the polishing abilities of six instruments using the obtained gloss values through the geometric optics approach (micro-Tri-gloss with 20°, 60°, and 85° measurement angles). The surface texture was validated using a field emission scanning electron microscope (FE-SEM). Based on the gloss values, we sorted polishing tools into three abrasive levels, and proposed polishing sequences to test the hypothesis that similar abrasive levels would leave equivalent gloss levels on dental composites. The three proposed, tested polishing sequences included: S1, Sof-Lex XT coarse disc, Sof-Lex XT fine disc, and OccluBrush; S2, Sof-Lex XT coarse disc, Prisma Gloss polishing paste, and OccluBrush; and S3, Sof-Lex XT coarse disc, Enhance finishing cups, and OccluBrush. S1 demonstrated significantly higher surface gloss than the other procedures (p < 0.05). The surface textures (FE-SEM micrographs) correlated well with the obtained gloss values. Nominally similar abrasive abilities did not result in equivalent polish levels, indicating that the polishing tools must be evaluated and cannot be judged based on their compositions or abrasive sizes. The geometric optic approach is an efficient and nondestructive method to characterize the polished surface of dental composites. Copyright © 2015. Published by Elsevier B.V.

  6. Surface processing for bulk niobium superconducting radio frequency cavities

    NASA Astrophysics Data System (ADS)

    Kelly, M. P.; Reid, T.

    2017-04-01

    The majority of niobium cavities for superconducting particle accelerators continue to be fabricated from thin-walled (2-4 mm) polycrystalline niobium sheet and, as a final step, require material removal from the radio frequency (RF) surface in order to achieve performance needed for use as practical accelerator devices. More recently bulk niobium in the form of, single- or large-grain slices cut from an ingot has become a viable alternative for some cavity types. In both cases the so-called damaged layer must be chemically etched or electrochemically polished away. The methods for doing this date back at least four decades, however, vigorous empirical studies on real cavities and more fundamental studies on niobium samples at laboratories worldwide have led to seemingly modest improvements that, when taken together, constitute a substantial advance in the reproducibility for surface processing techniques and overall cavity performance. This article reviews the development of niobium cavity surface processing, and summarizes results of recent studies. We place some emphasis on practical details for real cavity processing systems which are difficult to find in the literature but are, nonetheless, crucial for achieving the good and reproducible cavity performance. New approaches for bulk niobium surface treatment which aim to reduce cost or increase performance, including alternate chemical recipes, barrel polishing and ‘nitrogen doping’ of the RF surface, continue to be pursued and are closely linked to the requirements for surface processing.

  7. Surface processing for bulk niobium superconducting radio frequency cavities

    DOE PAGES

    Kelly, M. P.; Reid, T.

    2017-02-21

    The majority of niobium cavities for superconducting particle accelerators continue to be fabricated from thin-walled (2-4mm) polycrystalline niobium sheet and, as a final step, require material removal from the radio frequency (RF) surface in order to achieve performance needed for use as practical accelerator devices. More recently bulk niobium in the form of, single-or large-grain slices cut from an ingot has become a viable alternative for some cavity types. In both cases the so-called damaged layer must be chemically etched or electrochemically polished away. The methods for doing this date back at least four decades, however, vigorous empirical studies onmore » real cavities and more fundamental studies on niobium samples at laboratories worldwide have led to seemingly modest improvements that, when taken together, constitute a substantial advance in the reproducibility for surface processing techniques and overall cavity performance. This article reviews the development of niobium cavity surface processing, and summarizes results of recent studies. We place some emphasis on practical details for real cavity processing systems which are difficult to find in the literature but are, nonetheless, crucial for achieving the good and reproducible cavity performance. New approaches for bulk niobium surface treatment which aim to reduce cost or increase performance, including alternate chemical recipes, barrel polishing and 'nitrogen doping' of the RF surface, continue to be pursued and are closely linked to the requirements for surface processing.« less

  8. Surface processing for bulk niobium superconducting radio frequency cavities

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kelly, M. P.; Reid, T.

    The majority of niobium cavities for superconducting particle accelerators continue to be fabricated from thin-walled (2-4mm) polycrystalline niobium sheet and, as a final step, require material removal from the radio frequency (RF) surface in order to achieve performance needed for use as practical accelerator devices. More recently bulk niobium in the form of, single-or large-grain slices cut from an ingot has become a viable alternative for some cavity types. In both cases the so-called damaged layer must be chemically etched or electrochemically polished away. The methods for doing this date back at least four decades, however, vigorous empirical studies onmore » real cavities and more fundamental studies on niobium samples at laboratories worldwide have led to seemingly modest improvements that, when taken together, constitute a substantial advance in the reproducibility for surface processing techniques and overall cavity performance. This article reviews the development of niobium cavity surface processing, and summarizes results of recent studies. We place some emphasis on practical details for real cavity processing systems which are difficult to find in the literature but are, nonetheless, crucial for achieving the good and reproducible cavity performance. New approaches for bulk niobium surface treatment which aim to reduce cost or increase performance, including alternate chemical recipes, barrel polishing and 'nitrogen doping' of the RF surface, continue to be pursued and are closely linked to the requirements for surface processing.« less

  9. Additive manufacturing of glass for optical applications

    NASA Astrophysics Data System (ADS)

    Luo, Junjie; Gilbert, Luke J.; Bristow, Douglas A.; Landers, Robert G.; Goldstein, Jonathan T.; Urbas, Augustine M.; Kinzel, Edward C.

    2016-04-01

    Glasses including fused quartz have significant scientific and engineering applications including optics, communications, electronics, and hermetic seals. This paper investigates a filament fed process for Additive Manufacturing (AM) of fused quartz. Additive manufacturing has several potential benefits including increased design freedom, faster prototyping, and lower processing costs for small production volumes. However, current research in AM of glasses is limited and has focused on non-optical applications. Fused quartz is studied here because of its desirability for high-quality optics due to its high transmissivity and thermal stability. Fused quartz also has a higher working temperature than soda lime glass which poses a challenge for AM. In this work, fused quartz filaments are fed into a CO2 laser generated melt pool, smoothly depositing material onto the work piece. Single tracks are printed to explore the effects that different process parameters have on the morphology of printed fused quartz. A spectrometer is used to measure the thermal radiation incandescently emitted from the melt pool. Thin-walls are printed to study the effects of layer-to-layer height. Finally, a 3D fused quartz cube is printed using the newly acquired layer height and polished on each surface. The transmittance and index homogeneity of the polished cube are both measured. These results show that the filament fed process has the potential to print fused quartz with optical transparency and of index of refraction uniformity approaching bulk processed glass.

  10. 7 CFR 29.3648 - Thin Leaf (C Group).

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 2 2010-01-01 2010-01-01 false Thin Leaf (C Group). 29.3648 Section 29.3648... REGULATIONS TOBACCO INSPECTION Standards Grades § 29.3648 Thin Leaf (C Group). This group consists of leaves... specifications, and tolerances C1L Choice Quality Light-brown Thin Leaf. Ripe, thin, open leaf structure, smooth...

  11. 7 CFR 29.3648 - Thin Leaf (C Group).

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 7 Agriculture 2 2012-01-01 2012-01-01 false Thin Leaf (C Group). 29.3648 Section 29.3648... REGULATIONS TOBACCO INSPECTION Standards Grades § 29.3648 Thin Leaf (C Group). This group consists of leaves... specifications, and tolerances C1L Choice Quality Light-brown Thin Leaf. Ripe, thin, open leaf structure, smooth...

  12. 7 CFR 29.3648 - Thin Leaf (C Group).

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 7 Agriculture 2 2013-01-01 2013-01-01 false Thin Leaf (C Group). 29.3648 Section 29.3648... REGULATIONS TOBACCO INSPECTION Standards Grades § 29.3648 Thin Leaf (C Group). This group consists of leaves... specifications, and tolerances C1L Choice Quality Light-brown Thin Leaf. Ripe, thin, open leaf structure, smooth...

  13. 7 CFR 29.3648 - Thin Leaf (C Group).

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 2 2011-01-01 2011-01-01 false Thin Leaf (C Group). 29.3648 Section 29.3648... REGULATIONS TOBACCO INSPECTION Standards Grades § 29.3648 Thin Leaf (C Group). This group consists of leaves... specifications, and tolerances C1L Choice Quality Light-brown Thin Leaf. Ripe, thin, open leaf structure, smooth...

  14. 7 CFR 29.3648 - Thin Leaf (C Group).

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 7 Agriculture 2 2014-01-01 2014-01-01 false Thin Leaf (C Group). 29.3648 Section 29.3648... REGULATIONS TOBACCO INSPECTION Standards Grades § 29.3648 Thin Leaf (C Group). This group consists of leaves... specifications, and tolerances C1L Choice Quality Light-brown Thin Leaf. Ripe, thin, open leaf structure, smooth...

  15. Acquisition of thin coronal sectional dataset of cadaveric liver.

    PubMed

    Lou, Li; Liu, Shu Wei; Zhao, Zhen Mei; Tang, Yu Chun; Lin, Xiang Tao

    2014-04-01

    To obtain the thin coronal sectional anatomic dataset of the liver by using digital freezing milling technique. The upper abdomen of one Chinese adult cadaver was selected as the specimen. After CT and MRI examinations verification of absent liver lesions, the specimen was embedded with gelatin in stand erect position and frozen under profound hypothermia, and the specimen was then serially sectioned from anterior to posterior layer by layer with digital milling machine in the freezing chamber. The sequential images were captured by means of a digital camera and the dataset was imported to imaging workstation. The thin serial section of the liver added up to 699 layers with each layer being 0.2 mm in thickness. The shape, location, structure, intrahepatic vessels and adjacent structures of the liver was displayed clearly on each layer of the coronal sectional slice. CT and MR images through the body were obtained at 1.0 and 3.0 mm intervals, respectively. The methodology reported here is an adaptation of the milling methods previously described, which is a new data acquisition method for sectional anatomy. The thin coronal sectional anatomic dataset of the liver obtained by this technique is of high precision and good quality.

  16. Research on the material removal in the polishing of potassium dihydrogen phosphate crystals based on deliquescent action.

    PubMed

    Guo, Shaolong; Zhang, Feihu; Zhang, Yong; Luan, Dianrong

    2014-01-01

    Through the polishing experiments of potassium dihydrogen phosphate (KDP) crystals based on deliquescent action, the effect of several major factors, including crystal's initial surface state, polishing time, and revolution of polishing plate, on material removal was researched. Under certain experimental conditions, the rules of material removal were reached, and experimental results are discussed, which lays the foundation for popularization and application of polishing technology for KDP crystals based on deliquescent action.

  17. Study on optical polishing experiment of zerodur mirror

    NASA Astrophysics Data System (ADS)

    Wang, Huijun; Li, Hang; Wang, Peng; Guo, Wen; Wang, Yonggang; Du, Yan; Dong, Huiwen

    2014-08-01

    A zerodur mirror whose aperture is 900mm is chosen to be the primary mirror of an optical system. The mirror is polished by rapid polishing and precision polishing methods relatively. The final surface figures of the mirror are as follows: the peak-to-valley value (P-V value) is 0.204λ (λ=632.8nm), and the root-mean-square value (RMS value) is 0.016λ, which meet the requirement of the optical system. The results show that the polishing process is feasible.

  18. Development of a Computer-Controlled Polishing Process for X-Ray Optics

    NASA Technical Reports Server (NTRS)

    Khan, Gufran S.; Gubarev, Mikhail; Arnold, William; Ramsey, Brian

    2009-01-01

    The future X-ray observatory missions require grazing-incidence x-ray optics with angular resolution of < 5 arcsec half-power diameter. The achievable resolution depends ultimately on the quality of polished mandrels from which the shells are replicated. With an aim to fabricate better shells, and reduce the cost/time of mandrel production, a computer-controlled polishing machine is developed for deterministic and localized polishing of mandrels. Cylindrical polishing software is also developed that predicts the surface residual errors under a given set of operating parameters and lap configuration. Design considerations of the polishing lap are discussed and the effects of nonconformance of the lap and the mandrel are presented.

  19. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kutes, Yasemin; Luria, Justin; Sun, Yu

    Ion beam milling is the most common modern method for preparing specific features for microscopic analysis, even though concomitant ion implantation and amorphization remain persistent challenges, particularly as they often modify materials properties of interest. Atomic force microscopy (AFM), on the other hand, can mechanically mill specific nanoscale regions in plan-view without chemical or high energy ion damage, due to its resolution, directionality, and fine load control. As an example, AFM-nanomilling (AFM-NM) is implemented for top-down planarization of polycrystalline CdTe thin film solar cells, with a resulting decrease in the root mean square (RMS) roughness by an order of magnitude,more » even better than for a low incidence FIB polished surface. Subsequently AFM-based property maps reveal a substantially stronger contrast, in this case of the short-circuit current or open circuit voltage during light exposure. Furthermore, electron back scattering diffraction (EBSD) imaging also becomes possible upon AFM-NM, enabling direct correlations between the local materials properties and the polycrystalline microstructure. Smooth shallow-angle cross-sections are demonstrated as well, based on targeted oblique milling. As expected, this reveals a gradual decrease in the average short-circuit current and maximum power as the underlying CdS and electrode layers are approached, but a relatively consistent open-circuit voltage through the diminishing thickness of the CdTe absorber. AFM-based nanomilling is therefore a powerful tool for material characterization, uniquely providing ion-damage free, selective area, planar smoothing or low-angle sectioning of specimens while preserving their functionality. This then enables novel, co-located advanced AFM measurements, EBSD analysis, and investigations by related techniques that are otherwise hindered by surface morphology or surface damage.« less

  20. Polish system of education in maritime health care and medical assistance for seafarers.

    PubMed

    Chodnik, Tomasz; Jeżewska, Maria; Jaremin, Bogdan; Kotłowski, Andrzej; Leszczyńska, Irena; Grubman-Nowak, Marta

    2013-01-01

    The Polish public awareness of the crucial importance of the own maritime economy to the very existenceof the national state has its historical reasons. The Polish maritime involvement has seen several dramaticcrises, but the Polish nationals have become an established group in the global marine trade workforceand are entitled to the proper health care. In this paper the main maritime health issues are mentioned.To meet the issues, also the national education system provides the opportunities for both seafarers andmedical professionals. The Polish doctors can specialise in the maritime medicine. In many cases the generalmedicine students formations include these topics as well. The psychological aspects are also takeninto account, both of the education of the seafarers and the organisational structure of the Polish healthcare system. Some recent aspects of the Polish participation in the international cooperation in the fieldof the medical support of the maritime economy are also described.

  1. Ultraprecision finishing of micro-aspherical surface by ultrasonic assisted polishing; Technical Digest

    NASA Astrophysics Data System (ADS)

    Suzuki, Hirofumi; Kawamori, Ryota; Yamamoto, Yuji; Miyabara, Mitsuru; Okino, Tadashi; Hijikata, Yoshio; Moriwaki, Toshimichi

    2005-05-01

    Micro aspherical glass lenses are required for electronic devices, optical devices and advanced optical fiber transmission equipments. The glass lenses are manufactured by glass molding method by using micro ceramics dies such as tungsten carbide or silicon carbide (1). Therefore molding dies are most important and they were ground by ultra-precision grinding method with diamond wheel. Recently, the wavelength of used laser is becoming shorter and then the accuracies of the micro molding die are required to be much more precise (2). In this paper, ultrasonic assisted polishing methods/systems were developed in order to finish micro aspherical dies that were ground with micro diamond wheel. In the polishing experiments, the molding die of tungsten carbide was polished with diamond abrasives to test the basic polishing characteristics and the aspheric die was polished with proposed ultrasonic assisted polishing method.

  2. Electrochemical Polishing Applications and EIS of a Novel Choline Chloride-Based Ionic Liquid

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wixtrom, Alex I.; Buhler, Jessica E.; Reece, Charles E.

    2013-06-01

    Minimal surface roughness is a critical feature for high-field superconducting radio frequency (SRF) cavities used to engineer particle accelerators. Current methods for polishing Niobium cavities typically utilize solutions containing a mixture of concentrated sulfuric and hydrofluoric acid. Polishing processes such as these are effective, yet there are many hazards and costs associated with the use (and safe disposal) of the concentrated acid solutions. An alternative method for electrochemical polishing of the cavities was explored using a novel ionic liquid solution containing choline chloride. Potentiostatic electrochemical impedance spectroscopy (EIS) was used to analyze the ionic polishing solution. Final surface roughness ofmore » the Nb was found to be comparable to that of the acid-polishing method, as assessed by atomic force microscopy (AFM). This indicates that ionic liquid-based electrochemical polishing of Nb is a viable replacement for acid-based methods for preparation of SRF cavities.« less

  3. Internet Use of Polish by Polish Melburnians: Implications for Maintenance and Teaching

    ERIC Educational Resources Information Center

    Fitzgerald, Michael; Debski, Robert

    2006-01-01

    The Internet has become an important communication medium and it is having a significant impact on language use. The present study takes a "snapshot" of how the Polish language is currently used with modern communications technologies by Polish-Australians living in Melbourne. Through a questionnaire, it surveys which communications…

  4. The Relationship between Polish and Other Slavic Languages.

    ERIC Educational Resources Information Center

    Birkenmayer, Sigmund S.

    This paper discusses the relationship of Polish to the other languages considered to be within the Slavic group. The comparison is mainly phonological and considers the Proto-Slavic features still preserved in Polish as well as the distinctive features of Polish which have developed from Proto-Slavic. The development of vowels and consonants is…

  5. Polish Migrant Parents of Secondary School Boys in the United Kingdom

    ERIC Educational Resources Information Center

    Tkacz, Daria; McGhee, Derek

    2016-01-01

    This article focuses on the parents of secondary school Polish boys and their capacity to realise their educational and professional aspirations for their children. Our primary finding is that although many Polish parents face considerable challenges in manoeuvring through the educational system, some Polish parents display a level of agency…

  6. Subsurface Damage in Polishing Process of Silicon Carbide Ceramic

    PubMed Central

    Gu, Yan; Zhu, Wenhui; Lin, Jieqiong; Lu, Mingming; Kang, Mingshuo

    2018-01-01

    Subsurface damage (SSD) in the polishing process of silicon carbide (SiC) ceramic presents one of the most significant challenges for practical applications. In this study, the theoretical models of SSD depth are established on the basis of the material removal mechanism and indentation fracture mechanics in the SiC ceramic polishing process. In addition, the three-dimensional (3D) models of single grit polishing are also developed by using the finite element simulation; thereby, the dynamic effects of different process parameters on SSD depth are analyzed. The results demonstrate that the material removal was mainly in brittle mode when the cutting depth was larger than the critical depth of the brittle material. The SSD depth increased as the polishing depth and abrasive grain size increased, and decreased with respect to the increase in polishing speed. The experimental results suggested a good agreement with the theoretical simulation results in terms of SSD depth as a function of polishing depth, spindle speed, and abrasive grain size. This study provides a mechanistic insight into the dependence of SSD on key operational parameters in the polishing process of SiC ceramic. PMID:29584694

  7. Estimation of the dietary acrylamide exposure of the Polish population.

    PubMed

    Mojska, Hanna; Gielecińska, Iwona; Szponar, Lucjan; Ołtarzewski, Maciej

    2010-01-01

    The objective of our study was to determine acrylamide content in the Polish foods and to assess the average dietary acrylamide exposure of the Polish population. We analysed the acrylamide content in Polish food using GCQ-MS/MS method. The daily dietary acrylamide exposure was computed using a probabilistic approach for the total Polish population (1-96 years) and for the following age groups: 1-6, 7-18 and 19-96, using Monte Carlo simulation technique. To assess the Polish population exposure to acrylamide present in food, food consumption data was taken from the 'Household Food Consumption and Anthropometric Survey in Poland'. The mean content of acrylamide in tested 225 samples of foodstuffs taken randomly all over Poland, ranged widely from 11 to 3647 microg/kg of product. For the total Polish population (1-96 years) the estimated acrylamide mean exposure is 0.43 microg/kg of body weight per day. The main sources of dietary acrylamide in Polish population were as follow: bread--supplied 45% of total dietary acrylamide intake, French fries and potato crisps--23%, roasted coffee--19%. Copyright (c) 2010 Elsevier Ltd. All rights reserved.

  8. Design Considerations of Polishing Lap for Computer-Controlled Cylindrical Polishing Process

    NASA Technical Reports Server (NTRS)

    Khan, Gufran S.; Gubarev, Mikhail; Speegle, Chet; Ramsey, Brian

    2010-01-01

    The future X-ray observatory missions, such as International X-ray Observatory, require grazing incidence replicated optics of extremely large collecting area (3 m2) in combination with angular resolution of less than 5 arcsec half-power diameter. The resolution of a mirror shell depends ultimately on the quality of the cylindrical mandrels from which they are being replicated. Mid-spatial-frequency axial figure error is a dominant contributor in the error budget of the mandrel. This paper presents our efforts to develop a deterministic cylindrical polishing process in order to keep the mid-spatial-frequency axial figure errors to a minimum. Simulation studies have been performed to optimize the operational parameters as well as the polishing lap configuration. Furthermore, depending upon the surface error profile, a model for localized polishing based on dwell time approach is developed. Using the inputs from the mathematical model, a mandrel, having conical approximated Wolter-1 geometry, has been polished on a newly developed computer-controlled cylindrical polishing machine. We report our first experimental results and discuss plans for further improvements in the polishing process.

  9. High voltage performance of a dc photoemission electron gun with centrifugal barrel-polished electrodes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hernandez-Garcia, C.; Bullard, D.; Hannon, F.

    The design and fabrication of electrodes for direct current (dc) high voltage photoemission electron guns can significantly influence their performance, most notably in terms of maximum achievable bias voltage. Proper electrostatic design of the triple-point junction shield electrode minimizes the risk of electrical breakdown (arcing) along the insulator-cable plug interface, while the electrode shape is designed to maintain <10 MV/m at the desired operating voltage aiming at little or no field emission once conditioned. Typical electrode surface preparation involves diamond-paste polishing by skilled personnel, requiring several weeks of effort per electrode. In this work, we describe a centrifugal barrel-polishing techniquemore » commonly used for polishing the interior surface of superconducting radio frequency cavities but implemented here for the first time to polish electrodes for dc high voltage photoguns. The technique reduced polishing time from weeks to hours while providing surface roughness comparable to that obtained with diamond-paste polishing and with unprecedented consistency between different electrode samples. We present electrode design considerations and high voltage conditioning results to 360 kV (~11 MV/m), comparing barrel-polished electrode performance to that of diamond-paste polished electrodes. Here, tests were performed using a dc high voltage photogun with an inverted-geometry ceramic insulator design.« less

  10. High voltage performance of a dc photoemission electron gun with centrifugal barrel-polished electrodes

    DOE PAGES

    Hernandez-Garcia, C.; Bullard, D.; Hannon, F.; ...

    2017-09-11

    The design and fabrication of electrodes for direct current (dc) high voltage photoemission electron guns can significantly influence their performance, most notably in terms of maximum achievable bias voltage. Proper electrostatic design of the triple-point junction shield electrode minimizes the risk of electrical breakdown (arcing) along the insulator-cable plug interface, while the electrode shape is designed to maintain <10 MV/m at the desired operating voltage aiming at little or no field emission once conditioned. Typical electrode surface preparation involves diamond-paste polishing by skilled personnel, requiring several weeks of effort per electrode. In this work, we describe a centrifugal barrel-polishing techniquemore » commonly used for polishing the interior surface of superconducting radio frequency cavities but implemented here for the first time to polish electrodes for dc high voltage photoguns. The technique reduced polishing time from weeks to hours while providing surface roughness comparable to that obtained with diamond-paste polishing and with unprecedented consistency between different electrode samples. We present electrode design considerations and high voltage conditioning results to 360 kV (~11 MV/m), comparing barrel-polished electrode performance to that of diamond-paste polished electrodes. Here, tests were performed using a dc high voltage photogun with an inverted-geometry ceramic insulator design.« less

  11. Effect finishing and polishing procedures on the surface roughness of IPS Empress 2 ceramic.

    PubMed

    Boaventura, Juliana Maria Capelozza; Nishida, Rodrigo; Elossais, André Afif; Lima, Darlon Martins; Reis, José Mauricio Santos Nunes; Campos, Edson Alves; de Andrade, Marcelo Ferrarezi

    2013-01-01

    To evaluate the surface roughness of IPS Empress 2 ceramic when treated with different finishing/polishing protocols. Sixteen specimens of IPS Empress 2 ceramic were made from wax patterns obtained using a stainless steel split mold. The specimens were glazed (Stage 0-S0, control) and divided into two groups. The specimens in Group 1 (G1) were finished/polished with a KG Sorensen diamond point (S1), followed by KG Sorensen siliconized points (S2) and final polishing with diamond polish paste (S3). In Group 2 (G2), the specimens were finished/polished using a Shofu diamond point (S1), as well as Shofu siliconized points (S2) and final polishing was performed using Porcelize paste (S3). After glazing (S0) and following each polishing procedure (S1, S2 or S3), the surface roughness was measured using TALYSURF Series 2. The average surface roughness results were analyzed using ANOVA followed by Tukey post-hoc tests (α = 0.01) RESULTS: All of the polishing procedures yielded higher surface roughness values when compared to the control group (S0). S3 yielded lower surface roughness values when compared to S1 and S2. The proposed treatments negatively affected the surface roughness of the glazed IPS Empress 2 ceramic.

  12. High voltage performance of a dc photoemission electron gun with centrifugal barrel-polished electrodes

    NASA Astrophysics Data System (ADS)

    Hernandez-Garcia, C.; Bullard, D.; Hannon, F.; Wang, Y.; Poelker, M.

    2017-09-01

    The design and fabrication of electrodes for direct current (dc) high voltage photoemission electron guns can significantly influence their performance, most notably in terms of maximum achievable bias voltage. Proper electrostatic design of the triple-point junction shield electrode minimizes the risk of electrical breakdown (arcing) along the insulator-cable plug interface, while the electrode shape is designed to maintain <10 MV/m at the desired operating voltage aiming at little or no field emission once conditioned. Typical electrode surface preparation involves diamond-paste polishing by skilled personnel, requiring several weeks of effort per electrode. In this work, we describe a centrifugal barrel-polishing technique commonly used for polishing the interior surface of superconducting radio frequency cavities but implemented here for the first time to polish electrodes for dc high voltage photoguns. The technique reduced polishing time from weeks to hours while providing surface roughness comparable to that obtained with diamond-paste polishing and with unprecedented consistency between different electrode samples. We present electrode design considerations and high voltage conditioning results to 360 kV (˜11 MV/m), comparing barrel-polished electrode performance to that of diamond-paste polished electrodes. Tests were performed using a dc high voltage photogun with an inverted-geometry ceramic insulator design.

  13. [Features of adhesion of anaerobic periodontopathogenic bacteria and Candida albicans fungi to experimental samples of basis dental plastic depending on surface roughness and polishing method].

    PubMed

    Tsarev, V N; Ippolitov, E V; Trefilov, A G; Arutiunov, S D; Pivovarov, A A

    2014-01-01

    Study the main surface parameters of milled polyacrylic materials using atomic force microscopy and primary microbial adhesion of periodontopathogenic group bacteria and Candida albicans fungi taking into consideration the method of sample polishing. Studied samples: mill-treated without polishing (control); ergobox polished; polished in dental laboratory conditions; polished by a rubber brush in dentists' office. Microbial strains belonging to periodontopathogenic species (clinical isolates) that had been isolated from periodontal pockets of periodontitis patients: Porphyromonas gingivalis, Fusobacterium nucleatum, Streptococcus sanguis, C. albicans fungi were used for modelling experiments of primary adhesion of microbes to the material samples. S. sanguis had the highest degree of adhesion to polymer after milling, P. gingivalis, C. albicans--medium, F. nucleatum--low. A significant reduction of adhesion is observed during polishing in dental laboratory conditions or ergobox, less significant--during polishing in dental office. The data obtained allow to make a conclusion that the samples from polymer materials for preparation of prosthesis basis have varying degree of intensity of microbial adhesion of members of periodontopathogenic microflora and C. albicans fungi that depends on the polishing method, that accordingly determined the differences in colonization resistance against formation of microbial biofilm during polymer use in clinical conditions. . ,

  14. Quantification of microscopic surface features of single point diamond turned optics with subsequent chemical polishing

    NASA Astrophysics Data System (ADS)

    Cardenas, Nelson; Kyrish, Matthew; Taylor, Daniel; Fraelich, Margaret; Lechuga, Oscar; Claytor, Richard; Claytor, Nelson

    2015-03-01

    Electro-Chemical Polishing is routinely used in the anodizing industry to achieve specular surface finishes of various metals products prior to anodizing. Electro-Chemical polishing functions by leveling the microscopic peaks and valleys of the substrate, thereby increasing specularity and reducing light scattering. The rate of attack is dependent of the physical characteristics (height, depth, and width) of the microscopic structures that constitute the surface finish. To prepare the sample, mechanical polishing such as buffing or grinding is typically required before etching. This type of mechanical polishing produces random microscopic structures at varying depths and widths, thus the electropolishing parameters are determined in an ad hoc basis. Alternatively, single point diamond turning offers excellent repeatability and highly specific control of substrate polishing parameters. While polishing, the diamond tool leaves behind an associated tool mark, which is related to the diamond tool geometry and machining parameters. Machine parameters such as tool cutting depth, speed and step over can be changed in situ, thus providing control of the spatial frequency of the microscopic structures characteristic of the surface topography of the substrate. By combining single point diamond turning with subsequent electro-chemical etching, ultra smooth polishing of both rotationally symmetric and free form mirrors and molds is possible. Additionally, machining parameters can be set to optimize post polishing for increased surface quality and reduced processing times. In this work, we present a study of substrate surface finish based on diamond turning tool mark spatial frequency with subsequent electro-chemical polishing.

  15. Surface changes of metal alloys and high-strength ceramics after ultrasonic scaling and intraoral polishing.

    PubMed

    Yoon, Hyung-In; Noh, Hyo-Mi; Park, Eun-Jin

    2017-06-01

    This study was to evaluate the effect of repeated ultrasonic scaling and surface polishing with intraoral polishing kits on the surface roughness of three different restorative materials. A total of 15 identical discs were fabricated with three different materials. The ultrasonic scaling was conducted for 20 seconds on the test surfaces. Subsequently, a multi-step polishing with recommended intraoral polishing kit was performed for 30 seconds. The 3D profiler and scanning electron microscopy were used to investigate surface integrity before scaling (pristine), after scaling, and after surface polishing for each material. Non-parametric Friedman and Wilcoxon signed rank sum tests were employed to statistically evaluate surface roughness changes of the pristine, scaled, and polished specimens. The level of significance was set at 0.05. Surface roughness values before scaling (pristine), after scaling, and polishing of the metal alloys were 3.02±0.34 µm, 2.44±0.72 µm, and 3.49±0.72 µm, respectively. Surface roughness of lithium disilicate increased from 2.35±1.05 µm (pristine) to 28.54±9.64 µm (scaling), and further increased after polishing (56.66±9.12 µm, P <.05). The zirconia showed the most increase in roughness after scaling (from 1.65±0.42 µm to 101.37±18.75 µm), while its surface roughness decreased after polishing (29.57±18.86 µm, P <.05). Ultrasonic scaling significantly changed the surface integrities of lithium disilicate and zirconia. Surface polishing with multi-step intraoral kit after repeated scaling was only effective for the zirconia, while it was not for lithium disilicate.

  16. Surface changes of metal alloys and high-strength ceramics after ultrasonic scaling and intraoral polishing

    PubMed Central

    Noh, Hyo-Mi

    2017-01-01

    PURPOSE This study was to evaluate the effect of repeated ultrasonic scaling and surface polishing with intraoral polishing kits on the surface roughness of three different restorative materials. MATERIALS AND METHODS A total of 15 identical discs were fabricated with three different materials. The ultrasonic scaling was conducted for 20 seconds on the test surfaces. Subsequently, a multi-step polishing with recommended intraoral polishing kit was performed for 30 seconds. The 3D profiler and scanning electron microscopy were used to investigate surface integrity before scaling (pristine), after scaling, and after surface polishing for each material. Non-parametric Friedman and Wilcoxon signed rank sum tests were employed to statistically evaluate surface roughness changes of the pristine, scaled, and polished specimens. The level of significance was set at 0.05. RESULTS Surface roughness values before scaling (pristine), after scaling, and polishing of the metal alloys were 3.02±0.34 µm, 2.44±0.72 µm, and 3.49±0.72 µm, respectively. Surface roughness of lithium disilicate increased from 2.35±1.05 µm (pristine) to 28.54±9.64 µm (scaling), and further increased after polishing (56.66±9.12 µm, P<.05). The zirconia showed the most increase in roughness after scaling (from 1.65±0.42 µm to 101.37±18.75 µm), while its surface roughness decreased after polishing (29.57±18.86 µm, P<.05). CONCLUSION Ultrasonic scaling significantly changed the surface integrities of lithium disilicate and zirconia. Surface polishing with multi-step intraoral kit after repeated scaling was only effective for the zirconia, while it was not for lithium disilicate. PMID:28680550

  17. Tooth Surface Comparison after Air Polishing and Rubber Cup: A Scanning Electron Microscopy Study.

    PubMed

    Camboni, Sara; Donnet, Marcel

    2016-03-01

    To demonstrate, using microscopic observations, the difference between two well-known oral prophylaxis techniques: polishing paste and air polishing. The observations were performed on human enamel. Enamel samples were obtained from plaque-rich human teeth extracted for orthodontic or clinical purposes. In order to allow a reliable comparison between different applications, each enamel sample was divided into two parts: one underwent air-polishing, whereas polishing paste was applied to the other. AIR-FLOW® Master was selected together with AIR-FLOW® PLUS for the prophylaxis powder application. For the polishing-paste application, several different pastes where used, including Cleanic®, CCS®, Proxyt®, and SuperPolish. A comparative test control was also used by cleaning the enamel with sodium hypochlorite (6%). The enamel treated with AIR-FLOW PLUS showed a similar surface when compared to the control enamel; however, there was complete cleaning down to the tooth microstructure. On the other hand, use of the polishing paste resulted in an enamel surface that appeared abraded and flattened. Moreover, some of the natural irregular enamel surfaces demonstrated some filling in with debris. AIR-FLOW PLUS powder was able to more deeply clean without creating any damage to the enamel, making it suitable for regular cleaning treatments. The polishing pastes were found to abrade the enamel surface, to flatten it, and deposit debris into the microcavities. Both methods having different mechanical effects can therefore be considered as complementary, in that some patients experience a sense of "roughness" following a cleaning. A clinical recommendation for this experience would be to use the air polish first to clean the enamel surface, and follow with a little polishing paste to smooth the surface, if required.

  18. Effect of chemical disinfectant on the transverse strength of heat-polymerized acrylic resins subjected to mechanical and chemical polishing: an in vitro study.

    PubMed

    Sharan, Smitha; Kavitha, H R; Konde, Harish; Kalahasti, Deepthi

    2012-05-01

    To evaluate the effect of chemical disinfectant on the transverse strength of heat-polymerized acrylic resins subjected to mechanical and chemical polishing. A total of 256 rectangular specimens (65 * 10 * 3 mm) 128 per resin (Lucitone-199 and Acralyn-H) were fabricated. One side of each specimen was not polished and the other was either mechanically (n = 96) or chemically (n = 96) polished and immersed for 10, 30 and 60 minutes in 2% alkaline glutaraldehyde. Mechanically polished (n = 32) and chemically polished (n = 32) control specimens were immersed only in distilled water. The transverse strength (N/mm(2)) was tested for failure in a universal testing machine, at a crosshead speed of 5 mm/min. Data were statistically analyzed using 2-way ANOVA and Student t-test. chemical polishing resulted in significantly lower transverse strength values than mechanical polishing. Lucitone- 199 resin demonstrated the highest overall transverse strength for the materials tested. Heat-polymerized acrylic resins either mechanically or chemically polished, did not demonstrate significant changes in transverse strength during immersion in the disinfecting solution tested, regardless of time of immersion. Lucitone-199 resin demonstrated the highest overall transverse strength for the materials tested and significantly stronger than Acralyn-H with either type of polishing following immersion in 2% alkaline glutaraldehyde. There is a concern that immersion in chemical solutions often used for cleansing and disinfection of prostheses may undermine the strength and structure of denture base resins. In this study it was observed that, the transverse strength of samples of Lucitone-199 was higher than that of the samples of Acralyn-H. The chances of fracture of the denture made of Lucitone-199 are less than that of dentures made of Acralyn-H. The chemically polished dentures may be more prone to fracture than mechanically polished dentures.

  19. Effects of various polishing techniques and thermal cycling on the surface roughness and color change of polymer-based CAD/CAM materials.

    PubMed

    Acar, Burcu; Egilmez, Ferhan

    2018-04-01

    To investigate and compare the effects of several polishing systems and thermal cycling on the surface roughness and color change of various polymer-based CAD/CAM materials. Bar-shaped specimens (GC CeraSmart, CS; Lava Ultimate, LU and Vita Enamic, VE) were prepared. All specimens were polished with SiC papers. The specimens in Group A served as control and no additional surface polishing was applied. Final polishing was performed using diamond polishing paste (Diapolisher Paste) in Group B. In Group C, aluminum oxide abrasive discs (Sof-Lex XT Pop on) were used. Group D was polished with diamond impregnated spiral polishing system (EVE Diacomp Plus Twist). In Group E, polishing was done with rubber-based silicon abrasives (Polydentia). Thereafter, the specimens were submitted to thermal cycling. The surface roughness and color measurements were performed. Kruskal-Wallis and the Mann-Whitney U tests were applied for the evaluation of ΔE₀₀ data. Ra data were evaluated using three-way ANOVA. Pearson's correlation between Ra and ΔE₀₀ was further investigated. Neither the CAD/CAM materials nor thermal cycling affected the Ra data (P> 0.05). In contrast, significant difference was found among the polishing methods (P< 0.001). On the other hand, VE showed the highest color change whereas LU showed the lowest (P< 0.05). Additionally, the specimens in Group D exhibited significantly higher color change than other tested groups (P< 0.05). A moderate positive correlation was seen between Ra and ΔE₀₀ data of LU (rho = 0.390, P= 0.01). The diamond impregnated two-stage polishing procedure may not be an appropriate method for the tested CAD/CAM materials, as it resulted in the highest color change. On the other hand, all tested materials exhibited visually perceptible, but clinically acceptable color changes following the different polishing techniques. Additionally, diamond paste polishing could be a clinically acceptable procedure in terms of surface roughness. Copyright©American Journal of Dentistry.

  20. Superficial roughness on composite surface, composite-enamel and composite-dentin junctions after different finishing and polishing procedures. Part II: roughness with diamond finishing and differences between enamel composite vs body composite.

    PubMed

    Ferraris, Federico; Conti, Alessandro

    2014-01-01

    The following study asks three principle questions relative to composite finishing and composite polishing: 1) Will the superficial roughness of different restoration surfaces have different values, utilizing the same polishing system (multistep), after finishing with the tungsten carbide or diamond bur? 2) Under the same conditions of finishing and polishing sequences, will the composite surfaces (C), the composite-enamel (CE) and composite-dentin (CD) interfaces show different roughness values? 3) Will the surface roughness of composites of different translucency in the various phases of finishing and polishing, and on different interfaces, have different results? The null hypothesis is represented by the fact that there are no significant differences on roughness of composite restorations when polishing, after finishing with tungsten carbide or diamond burs. Furthermore, the null hypothesis is that there are no significant differences on roughness between polishing on composite surface, composite-enamel and composite-dentin interfaces, and finally there are no differences on roughness after finishing and polishing of two composite with different translucency. For the study, 56 class V cavities were prepared on extracted teeth. Restorations were done in nanofilled composite Filtek XTE (3M Espe) in a standard fashion, and then finished and polished. The 28 buccal cavities were restored on the surface with composite enamel and the 28 palatals with composite body. Finishing was done with fine toothing burs in tungsten carbide (16 blades) or fine grit diamond burs (46 μm), and made by the same manufacturer (Komet). The second phase of finishing was done with burs (with the same form as already mentioned) ultrafine toothing tungsten carbide (30 blades) or with extra and ultrafine grit diamond (25 and 8 μm). The polishing phase for both of the earlier sequences was done with the application of three rubber tips with decreasing abrasiveness and an application with a self-polishing brush. All measurements were taken from surfaces C, and interfaces CE and CD. Statistical analyses were carried out with c2 test (a = 0.05). 1) There were no relevant differences of surface roughness on the different surfaces if the polishing was done after finishing with tungsten carbide or diamond burs. 2) Keeping the same sequence of finishing and polishing, a difference was noticed between C, CE and CD, where the latter showed greater roughness. 3) Analyzing the data in all the phases of finishing and polishing on every interface, it can be concluded that the composite enamel and the composite body did not show different levels of superficial roughness. The clinical relevance could be resumed as follows: no difference after polishing, which is preceded by tungsten carbide or diamond finishing burs. The less favorable interface to be polished is CD, compared to CE and C. Considering two composites with different translucency, no difference on roughness after finishing and polishing were detected.

  1. Fracture toughness improvements of dental ceramic through use of yttria-stabilized zirconia (YSZ) thin-film coatings.

    PubMed

    Chan, Ryan N; Stoner, Brian R; Thompson, Jeffrey Y; Scattergood, Ronald O; Piascik, Jeffrey R

    2013-08-01

    The aim of this study was to evaluate strengthening mechanisms of yttria-stabilized zirconia (YSZ) thin film coatings as a viable method for improving fracture toughness of all-ceramic dental restorations. Bars (2mm×2mm×15mm, n=12) were cut from porcelain (ProCAD, Ivoclar-Vivadent) blocks and wet-polished through 1200-grit using SiC abrasive. A Vickers indenter was used to induce flaws with controlled size and geometry. Depositions were performed via radio frequency magnetron sputtering (5mT, 25°C, 30:1 Ar/O2 gas ratio) with varying powers of substrate bias. Film and flaw properties were characterized by optical microscopy, scanning electron microscopy (SEM), and X-ray diffraction (XRD). Flexural strength was determined by three-point bending. Fracture toughness values were calculated from flaw size and fracture strength. Data show improvements in fracture strength of up to 57% over unmodified specimens. XRD analysis shows that films deposited with higher substrate bias displayed a high %monoclinic volume fraction (19%) compared to non-biased deposited films (87%), and resulted in increased film stresses and modified YSZ microstructures. SEM analysis shows critical flaw sizes of 67±1μm leading to fracture toughness improvements of 55% over unmodified specimens. Data support surface modification of dental ceramics with YSZ thin film coatings to improve fracture toughness. Increase in construct strength was attributed to increase in compressive film stresses and modified YSZ thin film microstructures. It is believed that this surface modification may lead to significant improvements and overall reliability of all-ceramic dental restorations. Copyright © 2013 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  2. Nanophase Iron Globules in Lunar Soil

    NASA Technical Reports Server (NTRS)

    James, C. L.; Letsinger, S. L.; Wentworth, S. J.; McKay, D. S.; Basu, A.

    2003-01-01

    Micrometeoritic impacts on lunar soils produce melt and vapor. A patina of condensed vapor is deposited on lunar grains, the melt forms agglutinitic glass. In lunar soils, agglutinitic glass and rinds of grains host submicron-sized globules of pure Fe0 (Fe-rich globules larger than 1 micron usually contain other elements such as Ni, P, and S). Observation and measurement of such small size requires either back scattered electron (BSE) imaging with a high-resolution SEM or transmitted electron imaging with a TEM. The two techniques impose different limitations on the size-range of measurements. Resolution of BSE imaging of polished thin sections or grain mounts of lunar soils is at best around 4-5nm (JEOL 6340F field-emission (FE)-SEM at JSC). Therefore, Fe0 globules below 10nm in cross-sectional diameter are not truly measured. The upper limit of a millimeter or so is not a hindrance. In fact, it is an advantage because whole grains can be observed and mapped at varying magnifications. Angstrom-scale resolution of TEM images is more than sufficient to observe and measure the smallest of Fe0 globules that are about 1nm in cross-section. Microtoming edges of lunar grains; however, puts an upper size limitation of 50nm, at best, on the wafer, which more or less limits measuring Fe0 globules up to 30nm or so. Clearly, SEM and TEM techniques complement each other in obtaining the complete range of size distribution of Fe0 globules in lunar soils. Below we describe, in brief, our method of determining the size distribution of Fe0 globules in agglutinitic glass using BSE-SEM imaging and size measurement. Although our work is incomplete, we also include a table of results obtained so far, which understandably would be refined as we collect more data.

  3. Optical fiber sensor for breathing diagnostics

    NASA Astrophysics Data System (ADS)

    Claus, Richard O.; Distler, T.; Mecham, J. B.; Davis, B.; Arregui, F. J.; Matias, I. R.

    2004-06-01

    We report improvements of an optical fiber-based humidity sensor to the problem of breathing diagnostics. The sensor is fabricated by molecularly self-assembling selected polymers and functionalized inorganic nanoclusters into multilayered optical thin films on the cleaved and polished flat end of a singlemode optical fiber. Recent work has studied the synthesis process and the fundamental mechanisms responsible for the change in optical reflection from such a multicomponent film that occurs as a function of humidity and various chemicals. We briefly review that prior work as a way to introduce more recent developments. The paper then discusses the application of these humidity sensors to the analysis of air flow associated with breathing [1]. We have designed the sensor thin film materials to enable the detection of relative humidity over a wide range, from approximately 5 to 95%, and for response times as short as several microseconds. This fast response time allows the near real-time analysis of air flow and water vapor transport during a single breath, with the advantage of very small size. The use of multiple sensors spaced a known distance apart allows the measurement of flow velocity, and recent work indicates a variation in sensor response versus coating thickness.

  4. Research with Large Area Imaging X-Ray Telescope Sounding Rocket Program

    NASA Technical Reports Server (NTRS)

    Gorenstein, Paul

    1999-01-01

    We are engaged in a program to develop focussing hard X-ray telescopes in a double conical or Wolter 1 geometry that function up to 100 keV by employing small graze angles and multilayer coatings. Directly polished substrates are not an option because they are too thick to be nested efficiently. The only alternative is to fabricate the very thin substrates by replication. Our objective is the production of integral cylindrical substrates because they should result in better angular resolution than segmented foil geometries. In addition, integral cylinders would be more resistant to possible stress from deep multilayer coatings than segmented ones. Both electroforming of nickel (method of SkX, JET-X, and XMM) and epoxy replication are under consideration. Both processes can utilize the same types of mandrels and separation agents- While electroforming can produce substrates that are thin, the high density of the nickel may result in high weight optics for some missions. For convenience, experimentation with replication and coating is being carried out initially on flats. Our replication studies include trials with gold and carbon separation agents. This paper reports on our efforts with epoxy replicated optics.

  5. Cryogenic Test Results of Hextek Mirror

    NASA Technical Reports Server (NTRS)

    Hadaway, James; Stahl, H. Philip; Eng, Ron; Hogue, William

    2004-01-01

    A 250 mm diameter lightweight borosilicate mirror has been interferometrically tested from room-temperature down to 30 K at the X-Ray Calibration Facility (XRCF) at Marshall Space Flight Center (MSFC). The minor blank was manufactured by Hextek Corporation using a high-temperature gas fusion process and was then polished at MSFC. It is a sandwich-type mirror consisting of a thin face-sheet (approx.1.5 mm thick), a core structure (20 mm thick, approx.43 mm diameter cells, & 0.5-1.2 mm thick walls), and a thin back-sheet (3 mm thick). The mirror has a 2500 mm spherical radius-of- curvature @/lo). The areal density is 14 kg/sq m. The mirror was tested in the 1 m x 2 m chamber using an Instantaneous Phase Interferometer (PI) from ADE Phase Shift Technologies. The mirror was tested twice. The first test measured the change in surface figure from ambient to 30 K and the repeatability of the change. An attempt was then made by QED Technologies to cryo-figure the mirror using magnetorheological finishing. The second test measured the effectiveness of the cryo- figuring. This paper will describe the test goals, the test instrumentation, and the test results for these cryogenic tests.

  6. Measurements of liquid film thickness, concentration, and temperature of aqueous urea solution by NIR absorption spectroscopy

    NASA Astrophysics Data System (ADS)

    Pan, R.; Jeffries, J. B.; Dreier, T.; Schulz, C.

    2016-01-01

    A multi-wavelength near-infrared (NIR) diode laser absorption sensor has been developed and demonstrated for real-time monitoring of the thickness, solute concentration, and temperature of thin films of urea-water solutions. The sensor monitors the transmittance of three near-infrared diode lasers through the thin liquid film. Film thickness, urea mass fraction, and liquid temperature were determined from measured transmittance ratios of suitable combinations of lasers. Available laser wavelengths were selected depending on the variation of the NIR absorption spectrum of the solution with temperature and solute concentration. The spectral database was measured by a Fourier transform infrared spectrometer in the range 5500-8000 cm-1 for urea solutions between 5 and 40 wt% and temperatures between 298 and 338 K. A prototype sensor was constructed, and the sensor concept was first validated with measurements using a calibration cell providing liquid layers of variable thickness (200-1500 µm), urea mass fraction (5-40 wt%) and temperature (298-318 K). Temporal variations of film thickness and urea concentration were captured during the constant-temperature evaporation of a liquid film deposited on an optically polished heated quartz flat.

  7. Pressure distribution under flexible polishing tools. II - Cylindrical (conical) optics

    NASA Astrophysics Data System (ADS)

    Mehta, Pravin K.

    1990-10-01

    A previously developed eigenvalue model is extended to determine polishing pressure distribution by rectangular tools with unequal stiffness in two directions on cylindrical optics. Tool misfit is divided into two simplified one-dimensional problems and one simplified two-dimensional problem. Tools with nonuniform cross-sections are treated with a new one-dimensional eigenvalue algorithm, permitting evaluation of tool designs where the edge is more flexible than the interior. This maintains edge pressure variations within acceptable parameters. Finite element modeling is employed to resolve upper bounds, which handle pressure changes in the two-dimensional misfit element. Paraboloids and hyperboloids from the NASA AXAF system are treated with the AXAFPOD software for this method, and are verified with NASTRAN finite element analyses. The maximum deviation from the one-dimensional azimuthal pressure variation is predicted to be 10 percent and 20 percent for paraboloids and hyperboloids, respectively.

  8. Auger spectroscopic examination of MgF2-coated Al mirrors before and after UV irradiation

    NASA Technical Reports Server (NTRS)

    Heaney, J. B.; Herzig, H.; Osantowski, J. F.

    1977-01-01

    Magnesium fluoride protected Al films were studied since these mirrors are commonly used in astronomical instruments whenever a highly reflecting optical surface is required in the wavelength region from 1100 A to 2000 A. Freshly prepared samples of evaporated Al + 250-A thick MgF2 on glass were analyzed by Auger electron spectroscopy in conjunction with surface erosion by Ar(+) ion bombardment before and after UV irradiation. The analysis showed that a very thin layer of surface contamination and not bulk photolysis in the MgF2 film was reponsible for the irradiation-induced reflectance loss. Postirradiation polishing with a mild calcium carbonate abrasive can restore a mirror's reflectance by removing the photolyzed surface film without disturbing the MgF2 layer.

  9. Ageing and Learning Experiences: The Perspective of a Polish Senior Immigrant in Sweden

    ERIC Educational Resources Information Center

    Rawinski, Malgorzata Malec

    2017-01-01

    The general aim of this paper is to present some insights into Polish senior immigrants in Sweden. In particular, it seeks to identify and illustrate the important contribution of previous generations of Polish senior immigrants in building on the diverse culture, traditions and values of the Polish community (Polonia) in Sweden. The paper…

  10. Higher Magnification Imaging of the Polished Aluminum Collector Returned from the Genesis Mission

    NASA Technical Reports Server (NTRS)

    Rodriquez, Melissa C.; Burkett, P. J.; Allton, J. H.

    2011-01-01

    The polished aluminum collector (previously referred to as the polished aluminum kidney) was intended for noble gas analysis for the Gene-sis mission. The aluminum collector, fabricated from alloy 6061T, was polished for flight with alumina, then diamond paste. Final cleaning was performed by soak-ing and rinsing with hexane, then isopropanol, and last-ly megasonically energized ultrapure water prior to installation. It was mounted inside the collector canister on the thermal shield at JSC in 2000. The polished aluminum collector was not surveyed microscopically prior to flight.

  11. Method of fabricating a whispering gallery mode resonator

    NASA Technical Reports Server (NTRS)

    Savchenkov, Anatoliy A. (Inventor); Matkso, Andrey B. (Inventor); Iltchenko, Vladimir S. (Inventor); Maleki, Lute (Inventor)

    2011-01-01

    A method of fabricating a whispering gallery mode resonator (WGMR) is provided. The WGMR can be fabricated from a particular material, annealed, and then polished. The WGMR can be repeatedly annealed and then polished. The repeated polishing of the WGMR can be carried out using an abrasive slurry. The abrasive slurry can have a predetermined, constant grain size. Each subsequent polishing of the WGMR can use an abrasive slurry having a grain size that is smaller than the grain size of the abrasive slurry of the previous polishing iteration.

  12. Cometary particles - Thin sectioning and electron beam analysis

    NASA Technical Reports Server (NTRS)

    Bradley, J. P.; Brownlee, D. E.

    1986-01-01

    Thin sections (500 to 1000 angstroms thick) of individual micrometeorites (5 to 15 micrometers) have been prepared with an ultramicrotome equipped with a diamond knife. Electron microscope examination of these sections has revealed the internal structures of chondritic micrometeorites, and a subset of highly porous, fragile particles has been identified. Delicate meteoritic materials such as these are characteristic of debris from cometary meteors.

  13. Novel cavitation fluid jet polishing process based on negative pressure effects.

    PubMed

    Chen, Fengjun; Wang, Hui; Tang, Yu; Yin, Shaohui; Huang, Shuai; Zhang, Guanghua

    2018-04-01

    Traditional abrasive fluid jet polishing (FJP) is limited by its high-pressure equipment, unstable material removal rate, and applicability to ultra-smooth surfaces because of the evident air turbulence, fluid expansion, and a large polishing spot in high-pressure FJP. This paper presents a novel cavitation fluid jet polishing (CFJP) method and process based on FJP technology. It can implement high-efficiency polishing on small-scale surfaces in a low-pressure environment. CFJP uses the purposely designed polishing equipment with a sealed chamber, which can generate a cavitation effect in negative pressure environment. Moreover, the collapse of cavitation bubbles can spray out a high-energy microjet and shock wave to enhance the material removal. Its feasibility is verified through researching the flow behavior and the cavitation results of the negative pressure cavitation machining of pure water in reversing suction flow. The mechanism is analyzed through a computational fluid dynamics simulation. Thus, its cavitation and surface removal mechanisms in the vertical CFJP and inclined CFJP are studied. A series of polishing experiments on different materials and polishing parameters are conducted to validate its polishing performance compared with FJP. The maximum removal depth increases, and surface roughness gradually decreases with increasing negative outlet pressures. The surface becomes smooth with the increase of polishing time. The experimental results confirm that the CFJP process can realize a high material removal rate and smooth surface with low energy consumption in the low-pressure environment, together with compatible surface roughness to FJP. Copyright © 2017 Elsevier B.V. All rights reserved.

  14. Study of first electronic transition and hydrogen bonding state of ultra-thin water layer of nanometer thickness on an α-alumina surface by far-ultraviolet spectroscopy

    NASA Astrophysics Data System (ADS)

    Goto, Takeyoshi; Kinugasa, Tomoya

    2018-05-01

    The first electronic transition (A˜ ← X˜) and the hydrogen bonding state of an ultra-thin water layer of nanometer thickness between two α-alumina surfaces (0.5-20 nm) were studied using far-ultraviolet (FUV) spectroscopy in the wavelength range 140-180 nm. The ultra-thin water layer of nanometer thickness was prepared by squeezing a water droplet ( 1 μL) between a highly polished α-alumina prism and an α-alumina plate using a high pressure clamp ( 4.7 MPa), and the FUV spectra of the water layer at different thicknesses were measured using the attenuated total reflection method. As the water layer became thinner, the A˜ ← X˜ bands were gradually shifted to higher or lower energy relative to that of bulk water; at thicknesses smaller than 4 nm, these shifts were substantial (0.1-0.2 eV) in either case. The FUV spectra of the water layer with thickness < 4 nm indicate the formation of structured ice-like hydrogen bond (H-bond) layers for the higher energy shifts or the formation of slightly weaker H-bond layers as compared to those in the bulk liquid state for lower energy shifts. In either case, the H-bond structure of bulk liquid water is nearly lost at thicknesses below 4 nm, because of steric hydration forces between the α-alumina surfaces.

  15. Insulated InP (100) semiconductor by nano nucleus generation in pure water

    NASA Astrophysics Data System (ADS)

    Ghorab, Farzaneh; Es'haghi, Zarrin

    2018-01-01

    Preparation of specified designs on optoelectronic devices such as Light-Emitting Diodes (LEDs) and Laser Diodes (LDs) by using insulated thin films is very important. InP as one of those semiconductors which is used as optoelectronic devices, have two different kinds of charge carriers as n-InP and p-InP in the microelectronic industry. The surface preparation of this kind of semiconductor can be accomplished with individually chemical, mechanical, chemo - mechanical and electrochemical methods. But electrochemical method can be suitably replaced instead of the other methods, like CMP (Chemical Mechanical Polishing), because of the simplicity. In this way, electrochemically formation of insulated thin films by nano nucleus generation on semiconductor (using constant current density of 0.07 mA /cm2) studied in this research. Insulated nano nucleus generation and their growth up to thin film formation on semiconductor single crystal (100), n-InP, inpure water (0.08 µs/cm,25°c) characterized by Atomic Force Microscopy (AFM), Scanning Electron Microscopy (SEM), Four-point probe and Styloprofilometer techniques. The SEM images show active and passive regions on the n-InP surface and not uniform area on p-InP surface by passing through the passive condition. So the passive regions were nonuniform, and only the active regions were uniform and clean. The various semiconducting behavior in electrochemical condition, studied and compared with structural specification of InP type group (III-V).

  16. Effect finishing and polishing procedures on the surface roughness of IPS Empress 2 ceramic

    PubMed Central

    Nishida, Rodrigo; Elossais, André Afif; Lima, Darlon Martins; Reis, José Mauricio Santos Nunes; Campos, Edson Alves; de Andrade, Marcelo Ferrarezi

    2013-01-01

    Objective. To evaluate the surface roughness of IPS Empress 2 ceramic when treated with different finishing/polishing protocols. Materials and methods. Sixteen specimens of IPS Empress 2 ceramic were made from wax patterns obtained using a stainless steel split mold. The specimens were glazed (Stage 0–S0, control) and divided into two groups. The specimens in Group 1 (G1) were finished/polished with a KG Sorensen diamond point (S1), followed by KG Sorensen siliconized points (S2) and final polishing with diamond polish paste (S3). In Group 2 (G2), the specimens were finished/polished using a Shofu diamond point (S1), as well as Shofu siliconized points (S2) and final polishing was performed using Porcelize paste (S3). After glazing (S0) and following each polishing procedure (S1, S2 or S3), the surface roughness was measured using TALYSURF Series 2. The average surface roughness results were analyzed using ANOVA followed by Tukey post-hoc tests (α = 0.01) Results. All of the polishing procedures yielded higher surface roughness values when compared to the control group (S0). S3 yielded lower surface roughness values when compared to S1 and S2. Conclusions. The proposed treatments negatively affected the surface roughness of the glazed IPS Empress 2 ceramic. PMID:22724660

  17. Effects of Wet and Dry Finishing and Polishing on Surface Roughness and Microhardness of Composite Resins

    PubMed Central

    Nasoohi, Negin; Hoorizad, Maryam

    2017-01-01

    Objectives: This study aimed to assess the effect of wet and dry finishing and polishing on microhardness and roughness of microhybrid and nanohybrid composites. Materials and Methods: Thirty samples were fabricated of each of the Polofil Supra and Aelite Aesthetic All-Purpose Body microhybrid and Grandio and Aelite Aesthetic Enamel nanohybrid composite resins. Each group (n=30) was divided into three subgroups of D, W and C (n=10). Finishing and polishing were performed dry in group D and under water coolant in group W. Group C served as the control group and did not receive finishing and polishing. Surface roughness of samples was measured by a profilometer and their hardness was measured by a Vickers hardness tester. Data were analyzed using two-way ANOVA (P<0.05). Results: The smoothest surfaces with the lowest microhardness were obtained under Mylar strip without finishing/polishing for all composites (P<0.0001). The highest surface roughness was recorded for dry finishing/polishing for all composites (P<0.0001). Dry finishing/polishing increased the microhardness of all composites (P<0.0001). Conclusions: Dry finishing and polishing increases the microhardness and surface roughness of microhybrid and nanohybrid composite resins. PMID:29104597

  18. New perspectives in hydrodynamic radial polishing techniques for optical surfaces

    NASA Astrophysics Data System (ADS)

    Ruiz, Elfego; Sohn, Erika; Luna, Esteban; Salas, Luis; Cordero, Alberto; González, Jorge; Núñez, Manuel; Salinas, Javier; Cruz-González, Irene; Valdés, Jorge; Cabrera, Victor; Martínez, Benjamín

    2004-09-01

    In order to overcome classic polishing techniques, a novel hydrodynamic radial polishing tool (HyDRa) is presented; it is useful for the corrective lapping and fine polishing of diverse materials by means of a low-cost abrasive flux and a hydrostatic suspension system that avoids contact of the tool with the working surface. This tool enables the work on flat or curved surfaces of currently up to two and a half meters in diameter. It has the advantage of avoiding fallen edges during the polishing process as well as reducing tool wear out and deformation. The functioning principle is based on the generation of a high-velocity, high-pressure, abrasive emulsion flux with radial geometry. The polishing process is repeatable by means of the control of the tool operational parameters, achieving high degrees of precision and accuracy on optical and semiconductor surfaces, with removal rates of up to 9 mm3/hour and promising excellent surface polishing qualities. An additional advantage of this new tool is the possibility to perform interferometric measurements during the polishing process without the need of dismounting the working surface. A series of advantages of this method, numerical simulations and experimental results are described.

  19. Study of Profile Changes during Mechanical Polishing using Relocation Profilometry

    NASA Astrophysics Data System (ADS)

    Kumaran, S. Chidambara; Shunmugam, M. S.

    2017-10-01

    Mechanical polishing is a finishing process practiced conventionally to enhance quality of surface. Surface finish is improved by mechanical cutting action of abrasive particles on work surface. Polishing is complex in nature and research efforts have been focused on understanding the polishing mechanism. Study of changes in profile is a useful method of understanding behavior of the polishing process. Such a study requires tracing same profile at regular process intervals, which is a tedious job. An innovative relocation technique is followed in the present work to study profile changes during mechanical polishing of austenitic stainless steel specimen. Using special locating fixture, micro-indentation mark and cross-correlation technique, the same profile is traced at certain process intervals. Comparison of different parameters of profiles shows the manner in which metal removal takes place in the polishing process. Mass removal during process estimated by the same relocation technique is checked with that obtained using weight measurement. The proposed approach can be extended to other micro/nano finishing processes and favorable process conditions can be identified.

  20. Central overweight and obesity in Polish schoolchildren aged 7-18 years: secular changes of waist circumference between 1966 and 2012.

    PubMed

    Suder, Agnieszka; Gomula, Aleksandra; Koziel, Slawomir

    2017-07-01

    We investigated secular trends of body mass index (BMI) and waist circumference (WC) in Polish schoolchildren examined through a period of almost 50 years. Data on height, weight and WC came from four cross-sectional surveys conducted in Poland between 1966 and 2012, covering 34,005 boys and 34,008 girls. Raw data of BMI and WC were standardized for age classes. Statistical analyses included the Kruskal-Willis test and Pearson Chi-square test. BMI and WC increased during the studied period; however, the growth was higher for WC (increase by 0.56 and 0.44 SD scores for BMI and 1.05 and 0.77 SD scores for WC in boys and girls, respectively). In boys, secular changes in BMI and WC were similar across childhood, early and late adolescence, while in girls they differed, indicating change in the type of adipose tissue distribution to a more central one in late adolescent girls. During 46 years, there was a tendency to a greater increase of the fraction of individuals with central obesity than the overall one. Since abdominal fat deposit is more connected with higher health risks than subcutaneous fat pattern, probably the number of metabolic complications in Polish children and adolescents will intensify in the future. What is Known: • BMI has significant limitations related to fat distribution, while WC is a measure of central adiposity. • Greater central fat deposition increases the risk of many diseases; therefore, WC may serve as a diagnostic measure for detecting central obesity in children at risk. What is New: • In girls, changes in BMI and WC indicate change in adipose tissue distribution to a more central one in late adolescence girls. • Both general and abdominal obesity in Polish children increased significantly from 1966 to 2012, with the tendency to a greater increase of the fraction of individuals with central obesity than the overall one, implying the number of metabolic complications in Polish children and adolescents may intensify in the future.

  1. THE SCIENCE OF SCIENCE (NAUKOZNAWSTWO) IN POLAND: THE CHANGING THEORETICAL PERSPECTIVES AND POLITICAL CONTEXTS--A HISTORICAL SKETCH FROM THE 1910S TO 1993.

    PubMed

    Kokowski, Michał

    2015-01-01

    The article sketches the history of naukoznawstwo (literally meaning the science connoisseurship or the science of science or science studies) in Poland from the 1910s to the end of the Cold War (1991), and the recovery of full political independence in 1993. It outlines the changing research perspectives of this interdisciplinary field of knowledge in Poland against a background of changing political conditions caused by the reconfigurations of the political order. The first part of the article concerns the period from the 1910s, when Poland was occupied by Russia, Prussia, and Austria, through the regaining of independence by Poland in 1918, the reconstruction of the state in 1918-1939; the second part--World War II; the third part--the period from the initial period of Soviet dominance (1944-1954) in Poland and simultaneously the beginnings of the Cold War (1947-1954), the period 1955-1956 (when the Polish state was liberated from Sovietization), through the different political crises in October 1956, March 1968, December 1970, and June 1976, to the emergence of the Independent Self-governing Trade Union Solidarity in September 1980, the end of the Cold War (1991), and the recovery of full political independence in 1993. The article outlines the fundamental achievements of prominent Polish scholars (among others K. Twardowski, M. Ossowska, S. Ossowski, T. Kotarbiński, K. Ajdukiewicz, S. Michalski, F. Znaniecki, B. Suchodolski, L. Fleck, M. Choynowski, Z. Modzelewski, S. Amsterdamski), politicians (among others B. Bierut, E. Krasowska), politicians and scholars (H. Jabłoński, S. Kulczyński), as well as committees (among others the Academic Section of the Józef Mianowski Fund, The Science of Science Committee of the Polish Academy of Sciences), schools of thought (among others the Lvov-Warsaw School of Philosophy), and academic units (among others the Science of Science Seminar in Kraków, the Department for the History of Science and Technology of the Polish Academy of Sciences, and The Department of Praxeology and Science of Science at the Institute for the Philosophy and Sociology of the Polish Academy of Sciences).

  2. Structure and Assembly of Intracellular Mature Vaccinia Virus: Thin-Section Analyses

    PubMed Central

    Griffiths, Gareth; Roos, Norbert; Schleich, Sybille; Locker, Jacomine Krijnse

    2001-01-01

    In the preceding study (see accompanying paper), we showed by a variety of different techniques that intracellular mature vaccinia virus (vaccinia IMV) is unexpectedly complex in its structural organization and that this complexity also extends to the underlying viral core, which is highly folded. With that analysis as a foundation, we now present different thin-section electron microscopy approaches for analyzing the IMV and the processes by which it is assembled in infected HeLa cells. We focus on conventional epoxy resin thin sections as well as cryosections to describe key intermediates in the assembly process. We took advantage of streptolysin O's ability to selectively permeabilize the plasma membrane of infected cells to improve membrane contrast, and we used antibodies against bone fide integral membrane proteins of the virus to unequivocally identify membrane profiles in thin sections. All of the images presented here can be rationalized with respect to the model put forward for the assembly of the IMV in the accompanying paper. PMID:11602745

  3. Reduced Dimensionality Lithium Niobate Microsystems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Eichenfield, Matt

    2017-01-01

    The following report describes work performed under the LDRD program at Sandia National Laboratories October 2014 and September 2016. The work presented demonstrates the ability of Sandia Labs to develop state-of-the-art photonic devices based on thin film lithium niobate (LiNbO 3 ). Section 1 provides an introduction to integrated LiNbO 3 devices and motivation for developing thin film nonlinear optical systems. Section 2 describes the design, fabrication, and photonic performance of thin film optical microdisks fabricated from bulk LiNbO 3 using a bulk implantation method developed at Sandia. Sections 3 and 4 describe the development of similar thin film LiNbOmore » 3 structures fabricated from LiNbO 3 on insulator (LNOI) substrates and our demonstration of optical frequency conversion with state-of-the-art efficiency. Finally, Section 5 describes similar microdisk resonators fabricated from LNOI wafers with a buried metal layer, in which we demonstrate electro-optic modulation.« less

  4. Thin Film Ceramic Strain Sensor Development for High Temperature Environments

    NASA Technical Reports Server (NTRS)

    Wrbanek, John D.; Fralick, Gustave C.; Gonzalez, Jose M.; Laster, Kimala L.

    2008-01-01

    The need for sensors to operate in harsh environments is illustrated by the need for measurements in the turbine engine hot section. The degradation and damage that develops over time in hot section components can lead to catastrophic failure. At present, the degradation processes that occur in the harsh hot section environment are poorly characterized, which hinders development of more durable components, and since it is so difficult to model turbine blade temperatures, strains, etc, actual measurements are needed. The need to consider ceramic sensing elements is brought about by the temperature limits of metal thin film sensors in harsh environments. The effort at the NASA Glenn Research Center (GRC) to develop high temperature thin film ceramic static strain gauges for application in turbine engines is described, first in the fan and compressor modules, and then in the hot section. The near-term goal of this research effort was to identify candidate thin film ceramic sensor materials and provide a list of possible thin film ceramic sensor materials and corresponding properties to test for viability. A thorough literature search was conducted for ceramics that have the potential for application as high temperature thin film strain gauges chemically and physically compatible with the NASA GRCs microfabrication procedures and substrate materials. Test results are given for tantalum, titanium and zirconium-based nitride and oxynitride ceramic films.

  5. Geophysical Modelling and Multi-Scale Studies in the Arctic Seiland Igneous Province: Millimeter to Micrometer Scale Mapping of the Magnetic Sources by High Resolution Magnetic Microscopy

    NASA Astrophysics Data System (ADS)

    Pastore, Z.; Church, N. S.; McEnroe, S. A.; Oda, H.; ter Maat, G. W.

    2017-12-01

    Rocks samples can have wide range of magnetic properties depending on composition, amount of ferromagnetic minerals, grain sizes and microstructures. These influence the magnetic anomalies from the micro to the global scale making the study of the magnetic properties of interest for multiple applications. Later geological processes such as serpentinization can significantly influence these properties and change the nature of the magnetic anomalies. Particularly, magnetic properties such as remanent magnetization and magnetic susceptibility are directly linked to the magnetic mineralogy composition and grain size and can provide useful information about the geological history of the source. Scanning magnetic microscopy is a highly sensitive and high-resolution magnetometric technique for mapping the magnetic field over a planar surface of a rock sample. The device measures the vertical component of the field above the thin sections and the technique offers a spatial resolution down to tens of micrometers and thus can be used to investigate discrete magnetic mineral grains or magnetic textures and structures, and the magnetic history of the sample. This technique allows a direct correlation between the mineral chemistry (through both electron and optical microscopy) and the magnetic properties. We present as case-study three thin section magnetic scans of two dunite samples from the Reinfjord Ultramafic complex, in northern Norway. The selected thin sections show different magnetic properties which reflect the magnetic petrology. One of the thin sections is from a pristine dunite sample; the other two are highly serpentinized with newly formed magnetite found in multiple, few micrometer thick, veins. We present the preliminary results obtained applying a forward modelling approach on the magnetic anomaly maps acquired over the thin sections. Modelling consists of uniformly-magnetized polygonal bodies whose geometry is constrained by the thickness of the thin section and by the shape of the magnetic grains. The NRM direction in each polygon is modelled to fit the NRM magnetic field. Modelling helps in determining the NRM directions and intensities of discrete magnetic sources inside the thin sections and thus contributes to the study of the link between the magnetic petrology and the magnetic anomalies.

  6. Translations on Eastern Europe, Scientific Affairs, Number 557.

    DTIC Science & Technology

    1977-08-30

    research will be expanded further to increase theoretical knowledge of the extensive electrical engineering field. ERGONOMIA , A New PAN Publication...The first issue of the publication ERGONOMIA , an organ of the Ergonomics Committee attached to the PAN Presidium as well as the Ergonomie Commission...34Kronika" section, ERGONOMIA will record the scientific and research activities as well as association activities of various Polish and foreign

  7. Physical Activity of Underweight, Normal Weight and Overweight Polish Adolescents: The Role of Classmate and Teacher Support in Physical Education

    ERIC Educational Resources Information Center

    Kantanista, Adam; Osinski, Wieslaw; Bronikowski, Michal; Tomczak, Maciej

    2013-01-01

    The aim of the study was to investigate the relationships of classmate and teacher support during physical education (PE) lessons on moderate-to-vigorous physical activity of 14-16 year-old students whom were underweight, normal weight and overweight. The cross-sectional sample for the study concerned data from 1702 girls and 1547 boys, recruited…

  8. The microstructural character and evolution of fault rocks from the SAFOD core and potential weakening mechanisms along the San Andreas Fault (Invited)

    NASA Astrophysics Data System (ADS)

    Holdsworth, R. E.; van Diggelen, E.; Spiers, C.; de Bresser, J. H.; Smith, S. A.

    2009-12-01

    In the region of the SAFOD borehole, the San Andreas Fault (SAF) separates two very different geological terranes referred to here as the Salinian and Great Valley blocks (SB, GVB). The three sections of core preserve a diverse range of fault rocks and pass through the two currently active, highly localised slipping sections, the so-called ‘10480’ and ‘10830’ fault zones . These coincide with a broader region - perhaps as much as 100m wide - of high strain fault rocks formed at some time in the geological past, but now currently inactive. Both the slipping segments and older high strain zone(s) are developed in the GVB located NE of the terrane boundary. This is likely influenced by the phyllosilicate-rich protolith of the GVB and the large volume of trapped fluid known to exist NE and below the SAF in this region. Microstructurally, lower strain domains (most of Core 1 cutting the SB, significant parts of Core 3 cutting the GVB) preserve clear evidence for classic upper crustal cataclastic brittle faulting processes and associated fluid flow. The GVB in particular shows clear geological evidence for both fluid pressure and differential stress cycling (variable modes of hydrofacture associated with faults) during seismicity. There is also some evidence in all minor faults for the operation of limited amounts of solution-precipitation creep. High strain domains (much of Core 2 cutting the GVB, parts of Core 3 adjacent to the 10830 fault) are characterised by the development of foliated cataclasites and gouge largely due to the new growth of fine-grained phyllosilicate networks (predominantly smectite-bearing mixed layer clays, locally serpentinite, but not talc). The most deformed sections are characterised by the development of shear band fabrics and asymmetric folds. Reworking and reactivation is widespread manifested by: i) the preservation of one or more earlier generations of gouge preserved as clasts; and ii) by the development of later interconnected, polished and striated slip surfaces at low angles or sub-parallel to the foliation. These are coated with thin phyllosilicate films and are closely associated with the development of lozenge, arrow-head and triangular mineral veins (mostly calcite) inferred to be precipitated in dilation sites during slip. The largest displacement gouges also preserve numerous rounded ‘exotic’ clasts. These include serpentinite, crystalline carbonate, anhydrite and quartzofeldspathic units that texturally look very similar to clasts found in the SB. The SAFOD core fault rocks highlight the fundamental role played by fluid-rock interactions in upper crustal fault zones. There is clear evidence for the development of high pore fluid pressures (hydrofracture development), reaction weakening (phyllosilicate growth following cataclasis) and geometric weakening due to the development of weak interconnected layers (foliations, polished striated slip surfaces). There are also very significant similarities between the fault rocks seen here and those preserved along other deeply exhumed weak fault elsewhere in the world.

  9. Fabrication of Robust, Flat, Thinned, UV-Imaging CCDs

    NASA Technical Reports Server (NTRS)

    Grunthaner, Paula; Elliott, Stythe; Jones, Todd; Nikzad, Shouleh

    2004-01-01

    An improved process that includes a high-temperature bonding subprocess has been developed to enable the fabrication of robust, flat, silicon-based charge-coupled devices (CCDs) for imaging in ultraviolet (UV) light and/or for detecting low-energy charged particles. The CCDs in question are devices on which CCD circuitry has already been formed and have been thinned for backsurface illumination. These CCDs may be delta doped, and aspects of this type of CCD have been described in several prior articles in NASA Tech Briefs. Unlike prior low-temperature bonding subprocesses based on the use of epoxies or waxes, the high-temperature bonding subprocess is compatible with the deltadoping process as well as with other CCD-fabrication processes. The present improved process and its bonding, thinning, and delta-doping subprocesses, are characterized as postfabrication processes because they are undertaken after the fabrication of CCD circuitry on the front side of a full-thickness silicon substrate. In a typical case, it is necessary to reduce the thickness of the CCD to between 10 and 20 m in order to take advantage of back-side illumination and in order to perform delta doping and/or other back-side treatment to enhance the quantum efficiency. In the prior approach to the fabrication of back-side-illuminated CCDs, the thinning subprocess turned each CCD into a free-standing membrane that was fragile and tended to become wrinkled. In the present improved process, prior to thinning and delta doping, a CCD is bonded on its front side to a silicon substrate that has been prefabricated to include cutouts to accommodate subsequent electrical connections to bonding pads on the CCD circuitry. The substrate provides structural support to increase ruggedness and maintain flatness. At the beginning of this process, the back side of a CCD as fabricated on a full-thickness substrate is polished. Silicon nitride is deposited on the back side, opposite the bonding pads on the front side, in order to define a relatively thick frame. The portion of the CCD not covered by the frame is the portion to be thinned by etching.

  10. One-dimensional analysis of filamentary composite beam columns with thin-walled open sections

    NASA Technical Reports Server (NTRS)

    Lo, Patrick K.-L.; Johnson, Eric R.

    1986-01-01

    Vlasov's one-dimensional structural theory for thin-walled open section bars was originally developed and used for metallic elements. The theory was recently extended to laminated bars fabricated from advanced composite materials. The purpose of this research is to provide a study and assessment of the extended theory. The focus is on flexural and torsional-flexural buckling of thin-walled, open section, laminated composite columns. Buckling loads are computed from the theory using a linear bifurcation analysis and a geometrically nonlinear beam column analysis by the finite element method. Results from the analyses are compared to available test data.

  11. 21 CFR 872.6030 - Oral cavity abrasive polishing agent.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Miscellaneous Devices § 872.6030 Oral cavity abrasive polishing.... The abrasive polish is applied to the teeth by a handpiece attachment (prophylaxis cup). (b...

  12. 21 CFR 872.6030 - Oral cavity abrasive polishing agent.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Miscellaneous Devices § 872.6030 Oral cavity abrasive polishing.... The abrasive polish is applied to the teeth by a handpiece attachment (prophylaxis cup). (b...

  13. 21 CFR 872.6030 - Oral cavity abrasive polishing agent.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Miscellaneous Devices § 872.6030 Oral cavity abrasive polishing.... The abrasive polish is applied to the teeth by a handpiece attachment (prophylaxis cup). (b...

  14. 21 CFR 872.6030 - Oral cavity abrasive polishing agent.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Miscellaneous Devices § 872.6030 Oral cavity abrasive polishing.... The abrasive polish is applied to the teeth by a handpiece attachment (prophylaxis cup). (b...

  15. 21 CFR 872.6030 - Oral cavity abrasive polishing agent.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Miscellaneous Devices § 872.6030 Oral cavity abrasive polishing.... The abrasive polish is applied to the teeth by a handpiece attachment (prophylaxis cup). (b...

  16. Enclosed Cutting-And-Polishing Apparatus

    NASA Technical Reports Server (NTRS)

    Rossier, R. N.; Bicknell, B.

    1989-01-01

    Proposed apparatus cuts and polishes specimens while preventing contamination of outside environment or of subsequent specimens processed in it. Designed for use in zero gravity but also includes features useful in cutting and polishing of toxic or otherwise hazardous materials on Earth. Includes remote manipulator for handling specimens, cutting and polishing wire, inlets for gas and liquid, and outlets for waste liquid and gas. Replaceable plastic liner surrounds working space.

  17. Design Considerations of Polishing Lap for Computer-Controlled Cylindrical Polishing Process

    NASA Technical Reports Server (NTRS)

    Khan, Gufran S.; Gubarev, Mikhail; Arnold, William; Ramsey, Brian D.

    2009-01-01

    This paper establishes a relationship between the polishing process parameters and the generation of mid spatial-frequency error. The consideration of the polishing lap design to optimize the process in order to keep residual errors to a minimum and optimization of the process (speeds, stroke, etc.) and to keep the residual mid spatial-frequency error to a minimum, is also presented.

  18. [Polish historical collection at the University of Edinburgh].

    PubMed

    Tomaszewski, W

    1995-01-01

    The Polish School of Medicine, a joint Scottish-Polish academic enterprise, established in 1941 at the University of Edinburgh for soldiers-students in the Polish Forces, ceased its activity in 1949, four years after the end of the war. Owing to the stalinist terror in occupied Poland most of the 227 graduates remained in the West. There was a deep feeling of gratitude towards the University on the part of the graduates of the Polish School. The 25th anniversary of the School in 1966 was an opportunity to convoke in Edinburgh a world reunion of the graduates. At the academic ceremony two gold medals were presented to the University. The warm reception extended by the University, prompted the resolution to hold quinquennial world reunions in Edinburgh. Since then world reunions were held in Edinburgh every 5 years with meetings with the University authorities and presentation of gifts. By 1980 the number of gifts accumulated to such extent that the seminar room in the Erskine Medical Library was selected for the permanent display of the gifts; this served to intensify the collection of exhibits. Gifts were chosen to remind of certain events in the Polish history of medicine, especially items reflecting Polish links with Scotland. The highest achievement in the Scottish-Polish links, was of course the creation of the Polish School of Medicine. The official opening of the Historical Collection took place in June 1986 on the occasion of a world reunion on the 45th anniversary of the School. It was marked by the unveiling of a memorial plaque. On this ocasion another venture was also initiated: the opening of the Polish School of Medicine Memorial Fund at the University of Edinburgh. It was funded by the graduates to provide scholarship for young doctors from Poland. Another venture was the creation of the "Professor Antoni Jurasz lectureship" for Edinburgh professors to lecture in Medical Academies in Poland. The Historical Collection of the Polish School of Medicine at the University of Edinburgh is a permanent memorial to the magnanimity of the University left by the graduates. It is at the same time a windowshow of a 300 years old Scottish-Polish history of medicine.

  19. Calculation of Centrally Loaded Thin-Walled Columns Above the Buckling Limit

    NASA Technical Reports Server (NTRS)

    Reinitzhuber, F.

    1945-01-01

    When thin-walled columns formed from flanged sheet, such as used in airplane construction, are subjected to axial load, their behavior at failure varies according to the slenderness ratio. On long columns the axis deflects laterally while the cross section form is maintained; buckling results. The respective breaking load in the elastic range is computed by Euler's formula and for the plastic range by the Engesser- Karman formula. Its magnitude is essentially dependent upon the length. On intermediate length columns, especially where open sections are concerned, the cross section is distorted while the cross section form is preserved; twisting failure results. The buckling load in twisting is calculated according to Wagner and Kappus. On short columns the straight walls of low-bending resistance that form the column are deflected at the same time that the cross section form changes - buckling occurs without immediate failure. Then the buckling load of the total section computable from the buckling loads of the section walls is not the ultimate load; quite often, especially on thin-walled sections, it lies considerably higher and is secured by tests. Both loads, the buckling and the ultimate load are only in a small measure dependent upon length. The present report is an attempt to theoretically investigate the behavior of such short, thin-walled columns above the buckling load with the conventional calculating methods.

  20. Effect of finishing and polishing procedures on surface roughness, gloss and color of resin-based composites.

    PubMed

    Paravina, Rade D; Roeder, Leslie; Lu, Huan; Vogel, Karin; Powers, John M

    2004-08-01

    To evaluate the effects of different finishing and polishing procedures on surface roughness, gloss and color of five resin composites: two experimental microhybrid composites - FZ-Dentin (FZD) and FZ-Enamel (FZE), one commercial microhybrid composite - Esthet-X (EX), and two microfilled composites - Heliomolar (HM) and Renamel Microfill (RM). Surface roughness, gloss and color of the disc-shaped specimens (10 mm in diameter and 2-mm thick) were measured as Mylar (baseline), 16-fluted carbide bur and polishing were completed. Sixteen specimens of each composite were randomized to four groups of four. After finishing with a 16-fluted finishing bur, each group was polished by a different system: 1. Astropol (A), 2. Sof-lex disc (S), 3. Po-Go (P), 4. Enhance (E). Average surface roughness (Ra) was measured with a profilometer. Gloss measurements were performed using small-area glossmeter, while color coordinate values were recorded using a spectrophotometer. A deltaE*ab< or =1 was considered to be the limit of perceptibility. The order of surface roughness ranked according to polishing system (for all five composites together) was: P < S < E < A. The order of surface roughness ranked according to composites was: RM < FZD < FZ < HM < EX. The order of gloss ranked according to polishing system (for all five composites together) was: P > E > A > S. The order of gloss values for the polished composites (for each of four polishing systems) was: RM > FZD > FZE > HM > EX. Fisher's PLSD intervals at the 0.05 level of significance for comparisons of means of surface roughness among five composites and four polishing systems were 0.01 and 0.01 microm, respectively. Fisher's PLSD intervals at the 0.05 level of significance for comparisons of means of gloss among five composites and four polishing systems were 6 and 5 GU, respectively. Color differences (deltaE*ab) among five composites and four polishing methods were found to range from 0.2 to 1.1.

  1. Radiation and scattering by thin-wire structures in the complex frequency domain. [electromagnetic theory for thin-wire antennas

    NASA Technical Reports Server (NTRS)

    Richmond, J. H.

    1974-01-01

    Piecewise-sinusoidal expansion functions and Galerkin's method are employed to formulate a solution for an arbitrary thin-wire configuration in a homogeneous conducting medium. The analysis is performed in the real or complex frequency domain. In antenna problems, the solution determines the current distribution, impedance, radiation efficiency, gain and far-field patterns. In scattering problems, the solution determines the absorption cross section, scattering cross section and the polarization scattering matrix. The electromagnetic theory is presented for thin wires and the forward-scattering theorem is developed for an arbitrary target in a homogeneous conducting medium.

  2. The effect of different polishing systems on surface roughness and gloss of various resin composites.

    PubMed

    Da Costa, Juliana; Ferracane, Jack; Paravina, Rade D; Mazur, Rui Fernando; Roeder, Leslie

    2007-01-01

    The purpose of this in vitro study was to evaluate the surface finish and gloss of five direct resin composites polished with six polishing systems. One hundred and fifty disk-shaped composite specimens (D=10.0 mm, 2-mm-thick, N=30 per material) were made. One side of each specimen was finished with a 16-fluted carbide finishing bur and then polished. Five specimens of each resin composite were randomly assigned to one of the six polishing systems. The surface roughness and gloss were measured with a surface profilometer and a glossmeter. The results were analyzed by two-way analysis of variance and Tukey's t-test (p

  3. [The life of Polish students at the Polish School of Medicine at the University of Edinburgh].

    PubMed

    Gebertt, S

    1994-01-01

    The article has been written by a former student of the Polish School of Medicine at the University of Edinburgh, a member of the Polish Forces in Britain. The reminiscences concentrate on day to day life of others, like himself, seconded from the Forces to continue their medical studies. Statistical data concerning the activities of Polish School of Medicine are presented and analysed. Detailed mention is made of various routes by which Polish students reached Great Britain from the time of defeat and partition of Poland between Germany and Soviet Union. The various phases of relationship and attitudes between Polish Armed Forces and the body of students are described and illustrated by extracts from personal memoirs. The number of other topics is presented and discussed: The difficulties and problems encountered in living and studying amongst people, who although sympathetic, but whose language, culture and customs were completely foreign to the Poles. The ways in which individuals and groups of students tried and in many instances managed to overcome these obstacles, forging links with their Scottish colleagues and population at large. The participation in various joint activities like Settlement Day, work in agricultural camps, sports, Scottish students Unions and Representative Councils etc. are described. "Inner life" of Polish students concentrated in "Bursa" (an equivalent of University Residence) is presented in a light-hearted way. Large detachments of a foreign army, living, amongst albeit friendly population, are bound to cause, sometimes serious, friction. Very much in relation to this problem the role of Polish students as ambassadors of Poland and Polish Causes are presented and their value assessed.

  4. Wear Potential of Dental Ceramics and its Relationship with Microhardness and Coefficient of Friction.

    PubMed

    Freddo, Rafael Augusto; Kapczinski, Myriam Pereira; Kinast, Eder Julio; de Souza Junior, Oswaldo Baptista; Rivaldo, Elken Gomes; da Fontoura Frasca, Luis Carlos

    2016-10-01

    To evaluate, by means of pin-on-disk testing, the wear potential of different dental ceramic systems as it relates to friction parameters, surface finish, and microhardness. Three groups of different ceramic systems (Noritake EX3, Eris, Empress II) with 20 disks each (10 glazed, 10 polished) were used. Vickers microhardness (Hv) was determined with a 200-g load for 30 seconds. Friction coefficients (μ) were determined by pin-on-disk testing (5 N load, 600 seconds, and 120 rpm). Wear patterns were assessed by scanning electron microscopy (SEM). The results were analyzed using one-way ANOVA and Tukey's test, with the significance level set at α = 0.05. The coefficients of friction were as follows: Noritake EX3 0.28 ± 0.12 (polished), 0.33 ± 0.08 (glazed); Empress II 0.38 ± 0.08 (polished), 0.45 ± 0.05 (glazed); Eris 0.49 ± 0.05 (polished), 0.49 ± 0.06 (glazed). Microhardness measurements were as follows: Noritake EX3 530.7 ± 8.7 (polished), 525.9 ± 6.2 (glazed); Empress II 534.1 ± 8 (polished), 534.7 ± 4.5 (glazed); Eris, 511.7 ± 6.5 (polished), 519.5 ± 4.1 (glazed). The polished and glazed Noritake EX3 and polished and glazed Eris specimens showed statistically different friction coefficients. SEM image analysis revealed more surface changes, such as small cracks and grains peeling off, in glazed ceramics. Wear potential may be related to the coefficient of friction in Noritake ceramics, which had a lower coefficient than Eris ceramics. Within-group analysis showed no differences in polished or glazed specimens. The differences observed were not associated with microhardness. © 2015 by the American College of Prosthodontists.

  5. Evaluation of the validity of treatment decisions based on surrogate country models before introduction of the Polish FRAX and recommendations in comparison to current practice

    PubMed Central

    Narloch, Jerzy; Glinkowska, Bożena; Bandura, Małgorzata

    2016-01-01

    Introduction Patients diagnosed before the Polish FRAX was introduced may require re-evaluation and treatment changes if the diagnosis was established according to a surrogate country FRAX score. The aim of the study was to evaluate the validity of treatment decisions based on the surrogate country model before introduction of the Polish FRAX and to provide recommendations based on the current practice. Material and methods We evaluated a group of 142 postmenopausal women (70.7 ±8.9 years) who underwent bone mineral density measurements. We used 22 country-specific FRAX models and compared these to the Polish model. Results The mean risk values for hip and major osteoporotic fractures within 10 years were 4.575 (from 0.82 to 8.46) and 12.47% (from 2.18 to 21.65), respectively. In the case of a major fracture, 94.4% of women would receive lifestyle advice, and 5.6% would receive treatment according to the Polish FRAX using the guidelines of the National Osteoporosis Foundation (NOF). Polish treatment thresholds would implement pharmacotherapy in 32.4% of the study group. In the case of hip fractures, 45% of women according to the NOF would require pharmacotherapy but only 9.8% of women would qualify according to Polish guidelines. Nearly all surrogate FRAX calculator scores proved significantly different form Polish (p > 0.05). Conclusions More patients might have received antiresorptive medication before the Polish FRAX. This study recommends re-evaluation of patients who received medical therapy before the Polish FRAX was introduced and a review of the recommendations, considering the side effects of antiresorptive medication. PMID:29593808

  6. Evaluation of the validity of treatment decisions based on surrogate country models before introduction of the Polish FRAX and recommendations in comparison to current practice.

    PubMed

    Glinkowski, Wojciech M; Narloch, Jerzy; Glinkowska, Bożena; Bandura, Małgorzata

    2018-03-01

    Patients diagnosed before the Polish FRAX was introduced may require re-evaluation and treatment changes if the diagnosis was established according to a surrogate country FRAX score. The aim of the study was to evaluate the validity of treatment decisions based on the surrogate country model before introduction of the Polish FRAX and to provide recommendations based on the current practice. We evaluated a group of 142 postmenopausal women (70.7 ±8.9 years) who underwent bone mineral density measurements. We used 22 country-specific FRAX models and compared these to the Polish model. The mean risk values for hip and major osteoporotic fractures within 10 years were 4.575 (from 0.82 to 8.46) and 12.47% (from 2.18 to 21.65), respectively. In the case of a major fracture, 94.4% of women would receive lifestyle advice, and 5.6% would receive treatment according to the Polish FRAX using the guidelines of the National Osteoporosis Foundation (NOF). Polish treatment thresholds would implement pharmacotherapy in 32.4% of the study group. In the case of hip fractures, 45% of women according to the NOF would require pharmacotherapy but only 9.8% of women would qualify according to Polish guidelines. Nearly all surrogate FRAX calculator scores proved significantly different form Polish ( p > 0.05). More patients might have received antiresorptive medication before the Polish FRAX. This study recommends re-evaluation of patients who received medical therapy before the Polish FRAX was introduced and a review of the recommendations, considering the side effects of antiresorptive medication.

  7. Williamson Polishing & Plating Site

    EPA Pesticide Factsheets

    Williamson Polishing & Plating Co. Inc. was a plating shop located in the Martindale-Brightwood neighborhood of Indianapolis. The facility conducted job shop polishing and electroplating services. The vacant site contains a 14,651-square-foot building.

  8. Evaluation of two disinfection/sterilization methods on silicon rubber-based composite finishing instruments.

    PubMed

    Lacerda, Vánia A; Pereira, Leandro O; Hirata JUNIOR, Raphael; Perez, Cesar R

    2015-12-01

    To evaluate the effectiveness of disinfection/sterilization methods and their effects on polishing capacity, micomorphology, and composition of two different composite fiishing and polishing instruments. Two brands of finishing and polishing instruments (Jiffy and Optimize), were analyzed. For the antimicrobial test, 60 points (30 of each brand) were used for polishing composite restorations and submitted to three different groups of disinfection/sterilization methods: none (control), autoclaving, and immersion in peracetic acid for 60 minutes. The in vitro tests were performed to evaluate the polishing performance on resin composite disks (Amelogen) using a 3D scanner (Talyscan) and to evaluate the effects on the points' surface composition (XRF) and micromorphology (MEV) after completing a polishing and sterilizing routine five times. Both sterilization/disinfection methods were efficient against oral cultivable organisms and no deleterious modification was observed to point surface.

  9. A novel vibration assisted polishing device based on the flexural mechanism driven by the piezoelectric actuators

    NASA Astrophysics Data System (ADS)

    Wang, Guilian; Zhou, Xiaoqin; Ma, Peiqun; Wang, Rongqi; Meng, Guangwei; Yang, Xu

    2018-01-01

    The vibration assisted polishing has widely application fields because of higher machining frequency and better polishing quality, especially the polishing with the non-resonant mode that is regarded as a kind of promising polishing method. This paper reports a novel vibration assisted polishing device, consisting of the flexible hinge mechanism driven by the piezoelectric actuators, which is suitable for polishing planes or curve surfaces with slow curvature. Firstly, the generation methods of vibration trajectory are investigated for the same frequency and different frequency signals' inputs, respectively, and then the types of elliptic and Lissajous's vibration trajectories are generated respectively. Secondly, a flexural mechanism consisting of the right circular flexible hinges and the leaf springs is developed to produce two-dimensional vibration trajectory. Statics and dynamics investigating of this flexible mechanism are finished in detail. The analytical models about input and output compliances of the flexural mechanism are established according to the matrix-based compliance modeling, and the dynamic model of the flexural mechanism based on the Euler-Lagrange equation is also presented. The finite element model of the flexural mechanism was established to carry out the numerical simulation in order to testify the rationality of device design. Finally, the polishing experiment is carried out to prove the effectiveness of the vibration device. The experimental results show that this novel vibration assisted polishing device developed in this study can remove more effectively the cutting marks left by last process and obviously reduce the workpiece surface roughness.

  10. Strength Tests on Thin-walled Duralumin Cylinders in Torsion

    NASA Technical Reports Server (NTRS)

    Lundquist, Eugene E

    1932-01-01

    This report is the first of a series presenting the results of strength tests on thin-walled cylinders and truncated cones of circular and elliptical section; it comprises the results obtained to date from torsion (pure shear) tests on 65 thin-walled duralumin cylinders of circular section with ends clamped to rigid bulkheads. The effect of variations in the length/radius and radius/thickness ratios on the type of failure is indicated, and a semi-empirical equation for the shearing stress at maximum load is given.

  11. Profilometric analysis of two composite resins' surface repolished after tooth brush abrasion with three polishing systems.

    PubMed

    Uppal, Mudit; Ganesh, Arathi; Balagopal, Suresh; Kaur, Gurleen

    2013-07-01

    To evaluate the effect of three polishing protocols that could be implemented at recall on the surface roughness of two direct esthetic restorative materials. Specimens (n = 40) measuring 8 mm (length) × 5 mm (width) × 4 mm (height) were fabricated in an acrylic mold using two light-cured resin-based materials (microfilled composite and microhybrid composite). After photopolymerization, all specimens were finished and polished with one of three polishing protocols (Enhance, One Gloss, and Sof-Lex polishing systems). The average surface roughness of each treated specimen was determined using 3D optical profilometer. Next all specimens were brushed 60,000 times with nylon bristles at 7200 rpm using crosshead brushing device with equal parts of toothpaste and water used as abrasive medium. The surface roughness of each specimen was measured after brushing followed by repolishing with one of three polishing protocols, and then, the final surface roughness values were determined. The data were analyzed using one-way and two-factor analysis of variance (ANOVA) and Tukey's honestly significant difference (HSD). Significant difference (P < 0.05) in surface roughness was observed. Simulated brushing following initial polishing procedure significantly roughened the surface of restorative material (P < 0.05). Polishing protocols can be used to restore a smooth surface on esthetic restorative materials following simulated tooth brushing.

  12. Gloss and surface roughness produced by polishing kits on resin composites.

    PubMed

    Sadidzadeh, Ramtin; Cakir, Deniz; Ramp, Lance C; Burgess, John O

    2010-08-01

    To compare in vitro the surface roughness (Ra) and gloss (G) produced by three conventional and one experimental polishing kits on four resin composites. 24 discs were prepared (d = 12 mm, t = 4 mm) for each resin composite: Filtek Supreme Plus Body/A2 (FSB), Yellow Translucent (FST), Heliomolar/A2 (HM), and EsthetX/A2 (EX) following the manufacturers' instructions. They were finished with 320 grit silicon carbide paper for 80 seconds each. Polishing systems: Sof-Lex, Enhance-Pogo, Astropol and Experimental Discs/EXL-695, were applied following manufacturers' instructions. Each specimen was ultrasonically cleaned with distilled water and dried. Gloss and Ra were measured with a small area glossmeter (Novo-curve) and non-contact profilometer (Proscan 2000) following ISO 4288, respectively. The results were evaluated by two-way ANOVA followed by separate one-way ANOVA and Tukey/Kramer test (P = 0.05). There was a significant interaction of surface roughness and gloss between the composites and polishing systems (P < 0.05). The lowest surface roughness was recorded for FST polished with the Experimental kit. The highest gloss was obtained for FSB composite polished with the Experimental kit. The experimental polishing system produced smoothest surfaces (P < 0.05). The Enhance-Pogo and the experimental polishing kit produced highest gloss (P < 0.05).

  13. Fabrication of an optical component

    DOEpatents

    Nichols, Michael A.; Aikens, David M.; Camp, David W.; Thomas, Ian M.; Kiikka, Craig; Sheehan, Lynn M.; Kozlowski, Mark R.

    2000-01-01

    A method for forming optical parts used in laser optical systems such as high energy lasers, high average power lasers, semiconductor capital equipment and medical devices. The optical parts will not damage during the operation of high power lasers in the ultra-violet light range. A blank is first ground using a fixed abrasive grinding method to remove the subsurface damage formed during the fabrication of the blank. The next step grinds and polishes the edges and forms bevels to reduce the amount of fused-glass contaminants in the subsequent steps. A loose abrasive grind removes the subsurface damage formed during the fixed abrasive or "blanchard" removal process. After repolishing the bevels and performing an optional fluoride etch, the surface of the blank is polished using a zirconia slurry. Any subsurface damage formed during the loose abrasive grind will be removed during this zirconia polish. A post polish etch may be performed to remove any redeposited contaminants. Another method uses a ceria polishing step to remove the subsurface damage formed during the loose abrasive grind. However, any residual ceria may interfere with the optical properties of the finished part. Therefore, the ceria and other contaminants are removed by performing either a zirconia polish after the ceria polish or a post ceria polish etch.

  14. Process optimization for ultrasonic vibration assisted polishing of micro-structured surfaces on super hard material

    NASA Astrophysics Data System (ADS)

    Sun, Zhiyuan; Guo, Bing; Rao, Zhimin; Zhao, Qingliang

    2014-08-01

    In consideration of the excellent property of SiC, the ground micro-structured surface quality is hard to meet the requirement - consequently the ultrasonic vibration assisted polishing (UVAP) of micro-structures of molds is proposed in this paper. Through the orthogonal experiment, the parameters of UVAP of micro-structures were optimized. The experimental results show that, abrasive polishing process, the effect of the workpiece feed rate on the surface roughness (Ra), groove tip radius (R) and material removal rate (MRR) of micro-structures is significant. While, the UVAP, the most significant effect factor for Ra, R and MRR is the ultrasonic amplitude of the ultrasonic vibration. In addition, within the scope of the polishing process parameters selected by preliminary experiments, ultrasonic amplitude of 2.5μm, polishing force of 0.5N, workpiece feed rate of 5 mm·min-1, polishing wheel rotational speed of 50rpm, polishing time of 35min, abrasive size of 100nm and the polishing liquid concentration of 15% is the best technology of UVAP of micro-structures. Under the optimal parameters, the ground traces on the micro-structured surface were removed efficiently and the integrity of the edges of the micro-structure after grinding was maintained efficiently.

  15. Cleansing orthodontic brackets with air-powder polishing: effects on frictional force and degree of debris.

    PubMed

    Leite, Brisa Dos Santos; Fagundes, Nathalia Carolina Fernandes; Aragón, Mônica Lídia Castro; Dias, Carmen Gilda Barroso Tavares; Normando, David

    2016-01-01

    Debris buildup on the bracket-wire interface can influence friction. Cleansing brackets with air-powder polishing can affect this process. The aim of this study was to evaluate the frictional force and amount of debris remaining on orthodontic brackets subjected to prophylaxis with air-powder polishing. Frictional force and debris buildup on the surface of 28 premolar brackets were evaluated after orthodontic treatment. In one hemiarch, each bracket was subjected to air-powder polishing (n = 14) for five seconds, while the contralateral hemiarch (n = 14) served as control. Mechanical friction tests were performed and images of the polished bracket surfaces and control surfaces were examined. Wilcoxon test was applied for comparative analysis between hemiarches at p < 0.05. Brackets that had been cleaned with air-powder polishing showed lower friction (median = 1.27 N) when compared to the control surfaces (median = 4.52 N) (p < 0.01). Image analysis showed that the control group exhibited greater debris buildup (median = 2.0) compared with the group that received prophylaxis with air-powder polishing (median = 0.5) (p < 0.05). Cleansing orthodontic brackets with air-powder polishing significantly reduces debris buildup on the bracket surface while decreasing friction levels observed during sliding mechanics.

  16. Development of TIF based figuring algorithm for deterministic pitch tool polishing

    NASA Astrophysics Data System (ADS)

    Yi, Hyun-Su; Kim, Sug-Whan; Yang, Ho-Soon; Lee, Yun-Woo

    2007-12-01

    Pitch is perhaps the oldest material used for optical polishing, leaving superior surface texture, and has been used widely in the optics shop floor. However, for its unpredictable controllability of removal characteristics, the pitch tool polishing has been rarely analysed quantitatively and many optics shops rely heavily on optician's "feel" even today. In order to bring a degree of process controllability to the pitch tool polishing, we added motorized tool motions to the conventional Draper type polishing machine and modelled the tool path in the absolute machine coordinate. We then produced a number of Tool Influence Function (TIF) both from an analytical model and a series of experimental polishing runs using the pitch tool. The theoretical TIFs agreed well with the experimental TIFs to the profile accuracy of 79 % in terms of its shape. The surface figuring algorithm was then developed in-house utilizing both theoretical and experimental TIFs. We are currently undertaking a series of trial figuring experiments to prove the performance of the polishing algorithm, and the early results indicate that the highly deterministic material removal control with the pitch tool can be achieved to a certain level of form error. The machine renovation, TIF theory and experimental confirmation, figuring simulation results are reported together with implications to deterministic polishing.

  17. 75 FR 29974 - Application(s) for Duty-Free Entry of Scientific Instruments

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-05-28

    ... portions of vertebrate and invertebrate organisms embedded in plastic resins and cut into thin sections... vertebrate and invertebrate organisms embedded in plastic resins and cut into thin sections mounted on... Use: The instrument will be used to examine portions of vertebrate and invertebrate organisms embedded...

  18. Astronomy through the microscope: A workshop during the opening night of the 2016 IMC

    NASA Astrophysics Data System (ADS)

    Netjes, G. J.; de Vet, S.

    2016-01-01

    During the IMC workshop meteoritical thins sections were shown live with a microscope connected to the beamer. This article will provide a background to thin sections, what we can learn from them and the tour through the solar system we can take with them.

  19. Interferometric analysis of polishing surface with a petal tool

    NASA Astrophysics Data System (ADS)

    Salas-Sánchez, Alfonso; Leal-Cabrera, Irce; Percino Zacarias, Elizabeth; Granados-Agustín, Fermín S.

    2011-09-01

    In this work, we describe a phase shift interferometric monitoring of polishing processes produced by a petal tool over a spherical surface to obtain a parabolic surface. In the process, we used a commercial polishing machine; the purpose of this work is to have control of polishing time. To achieve this analysis, we used a Fizeau interferometer of ZYGO Company for optical shop testing, and the Durango software from Diffraction International Company. For data acquisition, simulation and evaluation of optical surfaces, we start polishing process with a spherical surface with 15.46 cm of diameter; a 59.9 cm of radius curvature and, with f/# 1.9.

  20. Ureilite Thin Section Preparation

    NASA Technical Reports Server (NTRS)

    Harrington, R.; Righter, K.

    2014-01-01

    Preparing thin and thick sections of ureilite type meteorites is a challenge that can confound even the most experienced section preparer. A common characteristic of these samples is the presence of carbon phases, particularly nanodiamonds, in the matrix along silicate grain boundaries, fractures, and cleavage plains [1]. The extreme hardness of the nanodiamonds presents a challenge to the section preparer in the form of high surface relief on the section. This hard material also causes considerable wear and tear on equipment and materials that are used for making the sections. These issues will be discussed and potentially helpful measures will be presented.

  1. Evaluation of the Effect of Surface Polishing, Oral Beverages and Food Colorants on Color Stability and Surface Roughness of Nanocomposite Resins

    PubMed Central

    Kumari, R Veena; Nagaraj, Hema; Siddaraju, Kishore; Poluri, Ramya Krishna

    2015-01-01

    Background: It is beyond doubt that finishing and polishing of a composite restoration enhance its esthetics and, is also essential for the health of the periodontium. A variety of instruments are commonly used for finishing and polishing tooth-colored restorative materials Thus, it is important to understand which type of surface finishing treatments would significantly affect the staining and surface irregularities of the composite resin restoration. Still one of the properties of the composite resins that have to pass the test of time is its color stability. In modern day dentistry, a large emphasis is laid over esthetics. Hence, it is important to understand the various agents capable of adversely affecting the esthetics of a restoration due to its staining capacity. Thus, the aim of this in vitro study was to evaluate the effect of surface polishing, oral beverages and food colorants on the color stability and surface roughness of nanocomposite resins. Materials and Methods: 90 Disks of nanocomposites resin (Filtek Z350 XT) measuring 8 mm in diameter and 2 mm in thickness were fabricated using a custom made silicon mold. Pre-polishing surface roughness (Ra1) of all the 90 samples were measured using a Surface Profilometer. The nano-composite disks were then randomly divided into 3 groups with 30 samples in each group. Group I: Control group: The samples were not subjected to any polishing procedures. Group II: Sof-Lex group: Samples subjected to polishing using different grits of Sof-Lex disks. Group III: Diamond polishing paste group: Samples were subjected with a polishing paste consisting of diamond particles. Following polishing procedures, the surface roughness of all samples were measured again to obtain change in surface roughness due to polishing procedures (Ra2), pre immersion spectrophotometric value (ΔE1) was also recorded for baseline color of the samples. The samples were then divided into subgroups (A, B, C, D, E), by including every first sample in Subgroup A, second in Subgroup B, third in Subgroup C, fourth in Subgroup D, and fifth in Subgroup E. Each was immersed in the respective test solution for 10 min, twice a day for 30 days. Group A - Tea, Group B - Coffee, Group C - Cola, Group D - Turmeric, Group E - Control (artificial saliva). Post immersion profilometric value was recorded to evaluate roughness bought about by the solutions (Ra3) and spectrophotometric value was recorded to evaluate the color change in samples (ΔE2). Results were statistically analyzed using ANOVA. Results: Higher mean roughness (Ra2-Ra1) value was recorded in Sof-Lex, followed by Diamond polishing paste and Control group. Comparison of surface roughness caused due to beverages and food colorant solution showed subgroup C (Coca Cola) increased surface roughness in all groups (Group I, II, III). Subgroup D (Turmeric) had the highest discoloration potential (P < 0001) in all groups, followed by coffee, tea, coca-cola and artificial saliva. Sof-Lex polishing System showed most color stability. Conclusion: Polishing procedures significantly roughen the surface of the restoration compared to the unpolished Mylar controls. One-step polishing system (diamond polishing paste) produces a smoother surface compared to a multi-step system (Sof-Lex polishing disks). Turmeric solution caused maximum staining of the samples, to a visually perceptible level. PMID:26229373

  2. Evaluation of the Effect of Surface Polishing, Oral Beverages and Food Colorants on Color Stability and Surface Roughness of Nanocomposite Resins.

    PubMed

    Kumari, R Veena; Nagaraj, Hema; Siddaraju, Kishore; Poluri, Ramya Krishna

    2015-07-01

    It is beyond doubt that finishing and polishing of a composite restoration enhance its esthetics and, is also essential for the health of the periodontium. A variety of instruments are commonly used for finishing and polishing tooth-colored restorative materials Thus, it is important to understand which type of surface finishing treatments would significantly affect the staining and surface irregularities of the composite resin restoration. Still one of the properties of the composite resins that have to pass the test of time is its color stability. In modern day dentistry, a large emphasis is laid over esthetics. Hence, it is important to understand the various agents capable of adversely affecting the esthetics of a restoration due to its staining capacity. Thus, the aim of this in vitro study was to evaluate the effect of surface polishing, oral beverages and food colorants on the color stability and surface roughness of nanocomposite resins. 90 Disks of nanocomposites resin (Filtek Z350 XT) measuring 8 mm in diameter and 2 mm in thickness were fabricated using a custom made silicon mold. Pre-polishing surface roughness (Ra1) of all the 90 samples were measured using a Surface Profilometer. The nano-composite disks were then randomly divided into 3 groups with 30 samples in each group. Group I: The samples were not subjected to any polishing procedures. Group II: Sof-Lex group: Samples subjected to polishing using different grits of Sof-Lex disks. Group III: Diamond polishing paste group: Samples were subjected with a polishing paste consisting of diamond particles. Following polishing procedures, the surface roughness of all samples were measured again to obtain change in surface roughness due to polishing procedures (Ra2), pre immersion spectrophotometric value (ΔE1) was also recorded for baseline color of the samples. The samples were then divided into subgroups (A, B, C, D, E), by including every first sample in Subgroup A, second in Subgroup B, third in Subgroup C, fourth in Subgroup D, and fifth in Subgroup E. Each was immersed in the respective test solution for 10 min, twice a day for 30 days. Group A - Tea, Group B - Coffee, Group C - Cola, Group D - Turmeric, Group E - Control (artificial saliva). Post immersion profilometric value was recorded to evaluate roughness bought about by the solutions (Ra3) and spectrophotometric value was recorded to evaluate the color change in samples (ΔE2). Results were statistically analyzed using ANOVA. Higher mean roughness (Ra2-Ra1) value was recorded in Sof-Lex, followed by Diamond polishing paste and Control group. Comparison of surface roughness caused due to beverages and food colorant solution showed subgroup C (Coca Cola) increased surface roughness in all groups (Group I, II, III). Subgroup D (Turmeric) had the highest discoloration potential (P < 0001) in all groups, followed by coffee, tea, coca-cola and artificial saliva. Sof-Lex polishing System showed most color stability. Polishing procedures significantly roughen the surface of the restoration compared to the unpolished Mylar controls. One-step polishing system (diamond polishing paste) produces a smoother surface compared to a multi-step system (Sof-Lex polishing disks). Turmeric solution caused maximum staining of the samples, to a visually perceptible level.

  3. Electrochemical Polishing Applications and EIS of a Vitamin B{sub 4}-Based Ionic Liquid

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wixtrom, Alex I.; Buhler, Jessica E.; Reece, Charles E.

    2013-01-01

    Modern particle accelerators require minimal interior surface roughness for Niobium superconducting radio frequency (SRF) cavities. Polishing of the Nb is currently achieved via electrochemical polishing with concentrated mixtures of sulfuric and hydrofluoric acids. This acid-based approach is effective at reducing the surface roughness to acceptable levels for SRF use, but due to acid-related hazards and extra costs (including safe disposal of used polishing solutions), an acid-free method would be preferable. This study focuses on an alternative electrochemical polishing method for Nb, using a novel ionic liquid solution containing choline chloride, also known as Vitamin B{sub 4} (VB{sub 4}). Potentiostatic electrochemicalmore » impedance spectroscopy (EIS) was also performed on the VB4-based system. Nb polished using the VB4-based method was found to have a final surface roughness comparable to that achieved via the acid-based method, as assessed by atomic force microscopy (AFM). These findings indicate that acid-free VB{sub 4}-based electrochemical polishing of Nb represents a promising replacement for acid-based methods of SRF cavity preparation.« less

  4. Plaque, gingival bleeding and calculus formation after supragingival scaling with and without polishing: a randomised clinical trial.

    PubMed

    Zanatta, Fabricio Batistin; Pinto, Tatiana Militz; Kantorski, Karla Zanini; Rösing, Cassiano Kuchenbecker

    2011-01-01

    The aim of this study was to compare the effect of polishing after scaling and root planing on supragingival plaque, calculus formation, and gingival bleeding. The study was designed as a split-mouth randomised clinical trial. Seventy-six patients were submitted to supragingival scaling on the six mandibular anterior teeth with manual curettes until a smooth surface was achieved. Subsequently, quadrants were randomly selected to be polished (test) or not (control) with a rubber cup and pumice. One, two and three weeks following treatment, a blinded examiner evaluated the visible plaque index, gingival bleeding index and the presence of supragingival calculus on the lingual tooth surfaces. The results showed that unpolished surfaces exhibited higher mean percentages of visible plaque in the third week. No statistically significant differences were observed between unpolished and polished sites related to gingival bleeding. Calculus formation was higher on unpolished sites than on polished sites at 2 and 3 weeks. Dental polishing after supragingival scaling contributed to reducing plaque and calculus formation. Polishing exerts an inhibitory effect on plaque and calculus formation.

  5. Thin Film Transistors On Plastic Substrates

    DOEpatents

    Carey, Paul G.; Smith, Patrick M.; Sigmon, Thomas W.; Aceves, Randy C.

    2004-01-20

    A process for formation of thin film transistors (TFTs) on plastic substrates replaces standard thin film transistor fabrication techniques, and uses sufficiently lower processing temperatures so that inexpensive plastic substrates may be used in place of standard glass, quartz, and silicon wafer-based substrates. The silicon based thin film transistor produced by the process includes a low temperature substrate incapable of withstanding sustained processing temperatures greater than about 250.degree. C., an insulating layer on the substrate, a layer of silicon on the insulating layer having sections of doped silicon, undoped silicon, and poly-silicon, a gate dielectric layer on the layer of silicon, a layer of gate metal on the dielectric layer, a layer of oxide on sections of the layer of silicon and the layer of gate metal, and metal contacts on sections of the layer of silicon and layer of gate metal defining source, gate, and drain contacts, and interconnects.

  6. Thick crystalline films on foreign substrates

    DOEpatents

    Smith, Henry I.; Atwater, Harry A.; Geis, Michael W.

    1986-01-01

    To achieve a uniform texture, large crystalline grains or, in some cases, a single crystalline orientation in a thick (>1 .mu.m) film on a foreign substrate, the film is formed so as to be thin (<1 .mu.m) in a certain section. Zone-melting recrystallization is initiated in the thin section and then extended into the thick section. The method may employ planar constriction patterns of orientation filter patterns.

  7. Thick crystalline films on foreign substrates

    DOEpatents

    Smith, H.I.; Atwater, H.A.; Geis, M.W.

    1986-03-18

    To achieve a uniform texture, large crystalline grains or, in some cases, a single crystalline orientation in a thick (>1 [mu]m) film on a foreign substrate, the film is formed so as to be thin (<1 [mu]m) in a certain section. Zone-melting recrystallization is initiated in the thin section and then extended into the thick section. The method may employ planar constriction patterns of orientation filter patterns. 2 figs.

  8. Weight discrepancy and body appreciation among women in Poland and Britain.

    PubMed

    Taylor, Donna; Szpakowska, Ilona; Swami, Viren

    2013-09-01

    Previous studies have suggested that the process of transmigration has detrimental effects on the body image of migrants relative to women in the country of origin. In the present work, we examined the body image of Polish migrants in Britain (n=153), Polish women in Poland (n=153), and a comparison group of British White women (n=110). Participants completed a measure of actual-ideal weight discrepancy and the Body Appreciation Scale (BAS). Contrary to hypotheses, our results showed that Polish women in Poland had significantly higher weight discrepancy than their counterparts in Britain. Further analyses showed that the BAS reduced to two dimensions among Polish participants, with Polish participants in Poland having significantly lower body appreciation than Polish migrants. We suggest that the sociocultural changes that have taken place in Eastern Europe may place women in that region at relatively high risk for developing negative body image. Copyright © 2013 Elsevier Ltd. All rights reserved.

  9. Carbon analyses of IDP's sectioned in sulfur and supported on beryllium films

    NASA Technical Reports Server (NTRS)

    Bradley, J. P.; Keller, L.; Thomas, K. L.; Vanderwood, T. B.; Brownlee, D. E.

    1993-01-01

    Carbon is the only major element in interplanetary dust whose abundance, distribution and chemical state are not well understood. Information about carbon could clarify the relationship between the various classes of IDP's, conventional meteorites, and sources (e.g., comets vs. asteroids). To date, the most reliable estimates of C abundance in Interplanetary Dust Particles (IDP's) have been obtained by analyzing particles on thick-flat Be substrates using thin-window energy-dispersive spectroscopy in the SEM. These estimates of C abundance are valid only if C is homogeneously distributed, because detected C x-rays originate from the outer 0.1 micrometers of the particle. An alternative and potentially more accurate method of measuring C abundances is to analyze multiple thin sections (each less than 0.1 less than 0.1 micrometers thick) of IDP's. These efforts however, have been stymied because of a lack of a suitable non-carbonaceous embedding medium and the availability of C-free conductive substrates. We have embedded and thin-sectioned IDP's in glassy sulfur, and transferred the thin sections to Be support films approximately 25 nm thick. The sections were then analyzed in a 200 KeV analytical TEM. S sublimes rapidly under vacuum in the TEM, leaving non-embedded sections supported on Be. Apart from quantitative C (and O) analyses, S sectioning dramatically expands the range of analytical measurements that can be performed on a single IDP.

  10. Color stability of nanocomposites polished with one-step systems.

    PubMed

    Ergücü, Zeynep; Türkün, L Sebnem; Aladag, Akin

    2008-01-01

    This study compared the color changes of five novel resin composites polished with two one-step polishing systems when exposed to coffee solution. The resin composites tested were Filtek Supreme XT, Grandio, CeramX, Premise and Tetric EvoCeram. A total of 150 discs (30/resin composites, 10 x 2 mm) were fabricated. Ten specimens/resin composites cured under Mylar strips served as the control. The other samples were polished with PoGo and OptraPol discs for 30 seconds using a slow speed handpiece and immersed in coffee (Nescafé) for seven days. Color measurements were made with Vita Easyshade at baseline and after one and seven days. Repeated Measures ANOVA and Bonferroni tests were used for statistical analyses (p< or =0.05). The differences between the mean DeltaE* values for the resin composites polished with two different one-step systems were statistically significant (p<0.05). After one week, all materials exhibited significant color changes compared to baseline. All Mylar finished specimens showed the most intense staining (p<0.05). There were no significant differences between the OptraPol and PoGo polished groups. Mylar-finished specimens of CeramX, Tetric EvoCeram, Premise and Filtek Supreme XT presented the greatest staining (p<0.05). For Grandio, there were no significant differences between the Mylar and PoGo groups, while the most stain resistant surfaces were attained with OptraPol. Removing the outermost resin layer by polishing procedures is essential to achieving a stain resistant, more esthetically stable surface. One-step polishing systems can be used successfully for polishing nanocomposites.

  11. International Federation of Library Associations Annual Conference Papers. Education and Research Division: Library Theory and Research Section (47th, Leipzig, East Germany, August 17-22, 1981).

    ERIC Educational Resources Information Center

    Kolodziejska, Jadwiga; And Others

    Seven of these ten papers are concerned with library research in specific countries; the remaining three deal with library planning and ethics in research. Titles are "The Library as a Cultural Institution," by Jadwiga Kolodziejska, Poland; "The International Seminar 'Book and Library in Society' of the Polish Book and Readers…

  12. Fundamental studies on silicon dioxide chemical mechanical polishing

    NASA Astrophysics Data System (ADS)

    Mahajan, Uday

    Chemical Mechanical Polishing (CMP) has lately been adopted on a large scale by the semiconductor industry for planarizing and patterning metal and dielectric films. Additionally, CMP has been used for hundreds of years for optical polishing. Still, several aspects of this process remain poorly understood. In this study, some results on CMP of SiO2 are presented with a view to characterizing the effects of abrasive properties and slurry chemistry on the polishing process. Additionally, some results from a novel in-situ friction force measuring instrument are also presented. The friction force results showed the effect of several parameters such as surface roughness, solution pH and ionic strength on wafer-pad interactions. Additionally, monitoring the friction as a function of velocity showed that the transition from boundary lubrication to full fluid-film lubrication depends on the roughness (conditioning) of the polishing pad. The parameters investigated in the polishing experiments include abrasive size and concentration. From the experimental results, it was found that an optimum concentration exists for each abrasive size, which shifts to lower values and becomes narrower as particle size increases. From calculations, this was attributed to a decreased ability of the large particles to chemically modify the surface of the SiO2 films. The smaller particles, having a much larger surface area, are able to better adsorb dissolution and abrasion products at high concentrations, thus leading to high removal rates under those conditions. Studies on the effect of slurry ionic strength showed that the ability of a metal ion to shield the surface charge on the surfaces interacting during polishing is what determined removal rate. This was due to the reduced electrostatic repulsion between the surfaces, which resulted in better contact and thus higher polishing rates. These results were corroborated by the earlier friction force measurements. Finally, the influence of particle density on polishing was shown, with denser alumina particles being able to polish SiO2 much more effectively. Some preliminary results on polishing with different abrasives as a function of slurry pH indicate that the material properties of the abrasives seem to change around their Iso-electric Points (IEP), resulting in almost no polishing, and severe particle contamination on the SiO2 surface.

  13. Use of Nanostructures in Fabrication of Large Scale Electrochemical Film

    NASA Astrophysics Data System (ADS)

    Chen, Chien Chon; Chen, Shih Hsun; Shyu, Sheang Wen; Hsieh, Sheng Jen

    Control of electrochemical parameters when preparing small-scale samples for academic research is not difficult. In mass production environments, however, maintenance of constant current density and temperature become a critical issue. This article describes the design of several molds for large work pieces. These molds were designed to maintain constant current density and to facilitate the occurrence of electrochemical reactions in designated areas. Large-area thin films with fine nanostructure were successfully prepared using the designed electrochemical molds and containers. In addition, current density and temperature could be controlled well. This electrochemical system has been verified in many experimental operations, including etching of Al surfaces; electro-polishing of Al, Ti and stainless steel; and fabrication of anodic alumina oxide (AAO), Ti-TiO2 interference membrane, TiO2 nanotubes, AAO-TiO2 nanotubes, Ni nanowires and porous tungsten

  14. Approach for axisymmetrical asphere polishing with full-area tools

    NASA Astrophysics Data System (ADS)

    Novi, Andrea; Melozzi, Mauro

    1999-09-01

    Aspherics up to 500 nm diameter in optical glass or in ceramic substrates have been fabricated using area- compensated polishing tools and conventional optical shop machines. The tool forms are derived starting from the actual shape of the part under figuring. The figure error is measured using an interferometer mounted on-line with the polishing machine. Measurements are taken after each polishing step to compute the new tool form. The process speeds up the fabrication of aspheres and it improves repeatability in the manufacturing of axisymmetrical optics using moderate cost equipment's up to astronomical requirements. In the paper we present some examples of polishing results using the above mentioned approach on different aspherics for space applications.

  15. Catalog of lunar mare basalts greater than 40 grams. Part 1: Major and trace chemistry, with megascopic descriptions and rock and thin section photographs

    NASA Technical Reports Server (NTRS)

    Lofgren, G. E.; Lofgren, E. M.

    1981-01-01

    Megascopic descriptions of 133 basaltic rocks returned from the Moon are presented along with photographs of each rock and its thin section, if available. The major and trace element chemistry of each is included wherever possible.

  16. Pipe support for use in a nuclear system

    DOEpatents

    Pollono, Louis P.; Mello, Raymond M.

    1977-01-01

    A pipe support for high temperature, thin-walled vertical piping runs used in a nuclear system. A cylindrical pipe transition member, having the same inside diameter as the thin-walled piping, replaces a portion of the piping where support is desired. The outside diameter of the pipe transition member varies axially along its vertical dimension. For a section of the axial length adjacent the upper and lower terminations of the pipe transition member, the outside diameter is the same as the outside diameter of the thin-walled piping to which it is affixed. Intermediate of the termination sections, the outside diameter increases from the top of the member to the bottom. Adjacent the lower termination section, the diameter abruptly becomes the same as the piping. Thus, the cylindrical transition member is formed to have a generally triangular shaped cross-section along the axial dimension. Load-bearing insulation is installed next to the periphery of the member and is kept in place by an outer ring clamp. The outer ring clamp is connected to pipe hangers, which provide the desired support for the vertical thin-walled piping runs.

  17. Do fossil vertebrate biominerals hold the key to the Palaeozoic climate?

    NASA Astrophysics Data System (ADS)

    Žigaitė, Ž.

    2012-04-01

    Fossil vertebrate hard tissues - teeth and dermoskeleton - are considered among the most geochemically stable biominerals, and therefore are widely used for palaeoenvironmental and palaeoclimatic reconstructions. Elemental and isotopic compositions of fossil dental tissues may provide unique palaeoenvironmental information, ranging from the diet and trophic positions on a food chain, to the palaeosalinity and water temperatures of ancient seas. However, the post-mortem alteration and re-crystallisation of fossil hard tissues may hamper these interpretations. Chemical composition and isotopic equilibrium of the biomineral change readily at any time from the earliest diagenesis to the final laboratory acid treatment during the fossil preparation. This is why particular attention shall be given to the preservation of fossil tissues, evaluating carefully the level of possible alteration in the primary geochemical composition. Pre-evaluation of fossil preservation can be made by semi-quantitative spot geochemistry analyses on fine polished teeth and scale thin sections using Energy Dispersive X-ray Spectroscopy (EDS), and help to preview the chemical composition of biomineral. The Electron Backscatter Diffractometry (EBSD) is useful to examine the cristallinity and possible structural alterations. In addition, rare earth element (REE) abundances can be measured in situ within the fine fossil tissues (such as enamel) using Laser Ablation Inductively Coupled Plasma Mass-spectrometry (LA-ICP-MS), giving evidence on the selective geochemical resilience between separate vertebrate hard tissues. Therefore, in order to decipher the geochemical signal correctly, the evaluation of preservation is a necessary starting point to any further studies of fossil biomineral geochemistry.

  18. Evaluation of the surface roughness of three heat-cured acrylic denture base resins with different conventional lathe polishing techniques: A comparative study.

    PubMed

    Rao, Duggineni Chalapathi; Kalavathy, N; Mohammad, H S; Hariprasad, A; Kumar, C Ravi

    2015-01-01

    Surface roughness promotes adhesion and colonization of denture plaque. Therefore, it is important to know the effects of polishing and finishing on the surface roughness of various acrylic resin materials. To evaluate and compare the effects of different conventional lathe polishing techniques on heat cured acrylic resins in producing surface roughness. Three different commercially available heat-cured acrylic resin materials namely DPI, Meliodent and Trevalon Hi were selected. 30 Specimens of each acrylic material (30 x 3 = 90, 10 x 60 x 2mm) were prepared and divided into 5 groups, each group consisted of 6 Nos. of specimens per material(6x3=18) and were grouped as Group A(unfinished), Group B (finished), Group C (Polishing Paste), Group D (Polishing Cake) and Group E (Pumice and Gold rouge). The resulted surface roughness (μm) was measured using Perthometer and observed under Scanning Electron Microscope. The values obtained were subjected statistical analyses. Among the materials tested, better results were obtained with Trevalon Hi followed by Meliodent and DPI. Among the polishing methods used, superior results were obtained with universal polishing paste followed by polishing cake; Pumice and Gold rouge. Although Pumice and Gold rouge values produced greater roughness value, they were well within the threshold value of 0.2 mm.

  19. Effects of chemo-mechanical polishing on CdZnTe X-ray and gamma-ray detectors

    DOE PAGES

    Egarievwe, Stephen E.; Hossain, Anwar; Okwechime, Ifechukwude O.; ...

    2015-06-23

    Here, mechanically polishing cadmium zinc telluride (CdZnTe) wafers for x-ray and gamma-ray detectors often is inadequate in removing surface defects caused by cutting them from the ingots. Fabrication-induced defects, such as surface roughness, dangling bonds, and nonstoichiometric surfaces, often are reduced through polishing and etching the surface. In our earlier studies of mechanical polishing with alumina powder, etching with hydrogen bromide in hydrogen peroxide solution, and chemomechanical polishing with bromine–methanol–ethylene glycol solution, we found that the chemomechanical polishing process produced the least surface leakage current. In this research, we focused on using two chemicals to chemomechanically polish CdZnTe wafers aftermore » mechanical polishing, viz. bromine–methanol–ethylene glycol (BME) solution, and hydrogen bromide (HBr) in a hydrogen peroxide and ethylene–glycol solution. We used x-ray photoelectron spectroscopy (XPS), current–voltage (I–V) measurements, and Am-241 spectral response measurements to characterize and compare the effects of each solution. The results show that the HBr-based solution produced lower leakage current than the BME solution. Results from using the same chemomechanical polishing solution on two samples confirmed that the surface treatment affects the measured bulk current (a combination of bulk and surface currents). XPS results indicate that the tellurium oxide to tellurium peak ratios for the mechanical polishing process were reduced significantly by chemomechanical polishing using the BME solution (78.9% for Te 3d 5/2O 2 and 76.7% for Te 3d 3/2O 2) compared with the HBr-based solution (27.6% for Te 3d 5/2O 2 and 35.8% for Te 3d 3/2O 2). Spectral response measurements showed that the 59.5-keV peak of Am-241 remained under the same channel number for all three CdZnTe samples. While the BME-based solution gave a better performance of 7.15% full-width at half-maximum (FWHM) compared with 7.59% FWHM for the HBr-based solution, the latter showed a smaller variation in performance of 0.39% FWHM over 7 days compared with 0.69% for the BME-based solution.« less

  20. Results of examination of the returned Surveyor 3 samples for particulate impacts

    NASA Technical Reports Server (NTRS)

    Cour-Palais, B. G.; Flaherty, R. E.; High, R. W.; Kessler, D. J.; Mckay, D. S.; Zook, H. A.

    1972-01-01

    The television housing and a section of the strut of the radar altimeter and Doppler velocity sensor were examined optically and with a scanning electron microscope for particulate impacts. The white surface of the camera was discolored during the months the Surveyor 3 was on the moon; however, most of the craters must have occurred as a result of lunar dust sandblasted by the LM exhaust. The polished section of the strut exhibits contamination which appears brown and seems to be partially composed of crystals. Electron microscopic analysis of the strut section indicated no craters of hypervelocity impact origin, confirmed pitting density results of the optical scans, and indicated that material in the craters is of lunar origin. No meteorite impacts larger than 25 microns were detected on the tubing section.

Top