Jones, S E; Ditner, S A; Freeman, C; Whitaker, C J; Lock, M A
1989-01-01
Bacterial counts obtained by using a new Anopore inorganic membrane filter were 21 to 33% higher than those obtained by using a Nuclepore polycarbonate membrane filter. In addition, the inorganic filter had higher flow rates, permitting lower vacuum pressures to be used, while the intrinsically flat, rigid surface resulted in easier focusing and sharp definition of bacteria across the whole field of view. Images PMID:2655539
Oßmann, Barbara E; Sarau, George; Schmitt, Sebastian W; Holtmannspötter, Heinrich; Christiansen, Silke H; Dicke, Wilhelm
2017-06-01
When analysing microplastics in food, due to toxicological reasons it is important to achieve clear identification of particles down to a size of at least 1 μm. One reliable, optical analytical technique allowing this is micro-Raman spectroscopy. After isolation of particles via filtration, analysis is typically performed directly on the filter surface. In order to obtain high qualitative Raman spectra, the material of the membrane filters should not show any interference in terms of background and Raman signals during spectrum acquisition. To facilitate the usage of automatic particle detection, membrane filters should also show specific optical properties. In this work, beside eight different, commercially available membrane filters, three newly designed metal-coated polycarbonate membrane filters were tested to fulfil these requirements. We found that aluminium-coated polycarbonate membrane filters had ideal characteristics as a substrate for micro-Raman spectroscopy. Its spectrum shows no or minimal interference with particle spectra, depending on the laser wavelength. Furthermore, automatic particle detection can be applied when analysing the filter surface under dark-field illumination. With this new membrane filter, analytics free of interference of microplastics down to a size of 1 μm becomes possible. Thus, an important size class of these contaminants can now be visualized and spectrally identified. Graphical abstract A newly developed aluminium coated polycarbonate membrane filter enables automatic particle detection and generation of high qualitative Raman spectra allowing identification of small microplastics.
ERIC Educational Resources Information Center
Shlyonsky, Vadim
2013-01-01
In the present article, a novel model of artificial membranes that provides efficient assistance in teaching the origins of diffusion potentials is proposed. These membranes are made of polycarbonate filters fixed to 12-mm plastic rings and then saturated with a mixture of creosol and "n"-decane. The electrical resistance and potential…
To measure airborne asbestos and other fibers, an air sample must represent the actual number and size of fibers. Typically, mixed cellulose ester (MCE, 0.45 or 0.8 µm pore size) and to a much lesser extent, capillary-pore polycarbonate (PC, 0.4 µm pore size) membrane filters are...
Diversifying biological fuel cell designs by use of nanoporous filters.
Biffinger, Justin C; Ray, Ricky; Little, Brenda; Ringeisen, Bradley R
2007-02-15
The use of proton exchange membranes (PEMs) in biological fuel cells limits the diversity of novel designs for increasing output power or enabling autonomous function in unique environments. Here we show that selected nanoporous polymer filters (nylon, cellulose, or polycarbonate) can be used effectively in place of PEMs in a miniature microbial fuel cell (mini-MFC, device cross-section 2 cm2), generating a power density of 16 W/m3 with an uncoated graphite felt oxygen reduction reaction (ORR) cathode. The incorporation of polycarbonate or nylon membranes into biological fuel cell designs produced comparable power and durability to Nafion-117 membranes. Also, high power densities for novel larger (5 cm3 anode volume, 0.6 W/m3) and smaller (0.025 cm3 projected geometric volume, average power density 10 W/m3) chamberless and pumpless microbial fuel cells were observed. As an additional benefit, the nanoporous membranes isolated the anode from invading natural bacteria, increasing the potential applications for MFCs beyond aquatic sediment environments. This work is a practical solution for decreasing the cost of biological fuel cells while incorporating new features for powering long-term autonomous devices.
Method for determining virus inactivation during sludge treatment processes.
Traub, F; Spillmann, S K; Wyler, R
1986-01-01
A simple and reliable method is described which allows determination of virus inactivation rates during sludge treatment processes in situ. Bacteriophage f2 was adsorbed onto an electropositive membrane filter which was then sandwiched between two polycarbonate membranes with pores smaller than the virus diameter. The resulting sandwich was fixed in an open filter holder, and several such devices were connected before being exposed in sludge-digesting tanks. The device described prevented uncontrolled virus escape, but allowed direct contact of the various inactivating or stabilizing substances present in the environment tested with the virus adsorbed to the carrier membrane. After exposure to an environment, the surviving fraction of virus was eluted from the inner filter and determined by plaque counting. By using polycarbonate membranes without pores for sandwiching, the influence of temperature alone on virus inactivation could be measured. Thermophilic fermentation at 60 degrees C and at 65 kPa pressure led to a bacteriophage f2 titer reduction of 3.5 log10 units per h, whereas during thermophilic digestion at 54.5 degrees C titers decreased 1.2 log10 units per h. During mesophilic digestion an inactivation rate of only 0.04 log10 units per h was observed. Under these latter conditions, temperature had only a minor effect (19%) on virus inactivation, whereas at 54.5 degrees C during thermophilic digestion heat accounted for 32% of the total inactivation, and during thermophilic fermentation at 60 degrees C temperature and pressure were 100% responsible for virus denaturation. PMID:3532955
Irreversible, direct bonding of nanoporous polymer membranes to PDMS or glass microdevices.
Aran, Kiana; Sasso, Lawrence A; Kamdar, Neal; Zahn, Jeffrey D
2010-03-07
A method for integrating porous polymer membranes such as polycarbonate, polyethersulfone and polyethylene terephthalate to microfluidic devices is described. The use of 3-aminopropyltriethoxysilane as a chemical crosslinking agent was extended to integrate membranes with PDMS and glass microfluidic channels. A strong, irreversible bond between the membranes and microfluidic structure was achieved. The bonding strength in the APTES treated devices was significantly greater than in devices fabricated using either a PDMS "glue" or two-part epoxy bonding method. Evaluation of a filtering microdevice and the pore structure via SEM indicates the APTES conjugation does not significantly alter the membrane transport function and pore morphology.
Atmospheric particulate measurements in Norfolk, Virginia
NASA Technical Reports Server (NTRS)
Storey, R. W., Jr.; Sentell, R. J.; Woods, D. C.; Smith, J. R.; Harris, F. S., Jr.
1975-01-01
Characterization of atmospheric particulates was conducted at a site near the center of Norfolk, Virginia. Air quality was measured in terms of atmospheric mass loading, particle size distribution, and particulate elemental composition for a period of 2 weeks. The objectives of this study were (1) to establish a mean level of air quality and deviations about this mean, (2) to ascertain diurnal changes or special events in air quality, and (3) to evaluate instrumentation and sampling schedules. Simultaneous measurements were made with the following instruments: a quartz crystal microbalance particulate monitor, a light-scattering multirange particle counter, a high-volume air sampler, and polycarbonate membrane filters. To assess the impact of meteorological conditions on air quality variations, continuous data on temperature, relative humidity, wind speed, and wind direction were recorded. Particulate elemental composition was obtained from neutron activation and scanning electron microscopy analyses of polycarbonate membrane filter samples. The measured average mass loading agrees reasonably well with the mass loadings determined by the Virginia State Air Pollution Control Board. There are consistent diurnal increases in atmospheric mass loading in the early morning and a sample time resolution of 1/2 hour seems necessary to detect most of the significant events.
Caught in a net: Retention efficiency of microplankton ≥ 10 and < 50 μm collected on mesh netting
NASA Astrophysics Data System (ADS)
Molina, Vanessa; Robbins-Wamsley, Stephanie H.; Riley, Scott C.; First, Matthew R.; Drake, Lisa A.
2018-03-01
Living organisms ≥ 10 μm and < 50 μm in ballast water discharged from ships are typically collected by filtering samples through a monofilament mesh net with pore openings sized to retain organisms ≥ 10 μm. This (or any) filtering method does not result in perfect size fractionation, and it can induce stress, mortality, and loss of organisms that, in turn, may underestimate the concentration of organisms within samples. To address this loss, the retention efficiency (RE) was determined for six filtration approaches using laboratory cultures of microalgae and ambient marine organisms. The approaches employed a membrane filter or mesh nettings of different compositions (nylon, stainless steel, polyester, and polycarbonate), nominal pore sizes (5, 7, and 10 μm), and filtering sequences (e.g., pre-filtering water through a coarse filter). Additionally, in trials with polycarbonate track etched (PCTE) membrane filters, water was amended with particulate material to increase turbidity. Organisms ≥ 10 μm were counted in the material retained on the filter (the filtrand), the material passing through the filter (the filtrate), and the whole water (i.e., unfiltered water). In addition, variable fluorescence fluorometry was used to gauge the relative photochemical yield of phytoplankton-a proximal measurement of the physiological status of phytoplankton-in the size fractions. Further, the mesh types and filters were examined using scanning electron microscopy, which showed irregular openings. The RE of cultured organisms-calculated as the concentration in the filtrand relative to combined concentration in the filtrand and the filtrate-was high for all filtration approaches when laboratory cultures were assessed (> 93%), but RE ranged from 66 to 98% when mixed assemblages of ambient organisms were evaluated. Although PCTE membrane filters had the highest RE (98%), it was not significantly higher than the efficiencies of the 7-μm polyester, Double 7-μm polyester, and Dual 35-μm and 7-μm polyester approaches, but it was significantly higher than the 5-μm nylon and 5-μm stainless steel techniques. This result suggests that PCTE membrane filters perform comparably to 7-μm polyester meshes, so that any of these approaches could be used for concentrating organisms. However, the potential for handling loss is inherently lower for one rinsing step rather than two. Therefore, it is recommended that, either PCTE filters or 7-μm polyester mesh could be used to concentrate organisms ≥ 10 μm and < 50 μm. In trials conducted using a 10-μm PCTE filters with water amended to increase the particulate concentration, no significant difference in RE of ambient organisms was found compared to unamended water. Finally, photochemical yield did not vary significantly between organisms in the filtrand or filtrate, regardless of the filtration approach used.
Direct transfer of graphene onto flexible substrates.
Martins, Luiz G P; Song, Yi; Zeng, Tingying; Dresselhaus, Mildred S; Kong, Jing; Araujo, Paulo T
2013-10-29
In this paper we explore the direct transfer via lamination of chemical vapor deposition graphene onto different flexible substrates. The transfer method investigated here is fast, simple, and does not require an intermediate transfer membrane, such as polymethylmethacrylate, which needs to be removed afterward. Various substrates of general interest in research and industry were studied in this work, including polytetrafluoroethylene filter membranes, PVC, cellulose nitrate/cellulose acetate filter membranes, polycarbonate, paraffin, polyethylene terephthalate, paper, and cloth. By comparing the properties of these substrates, two critical factors to ensure a successful transfer on bare substrates were identified: the substrate's hydrophobicity and good contact between the substrate and graphene. For substrates that do not satisfy those requirements, polymethylmethacrylate can be used as a surface modifier or glue to ensure successful transfer. Our results can be applied to facilitate current processes and open up directions for applications of chemical vapor deposition graphene on flexible substrates. A broad range of applications can be envisioned, including fabrication of graphene devices for opto/organic electronics, graphene membranes for gas/liquid separation, and ubiquitous electronics with graphene.
Direct transfer of graphene onto flexible substrates
Martins, Luiz G. P.; Song, Yi; Zeng, Tingying; Dresselhaus, Mildred S.; Kong, Jing; Araujo, Paulo T.
2013-01-01
In this paper we explore the direct transfer via lamination of chemical vapor deposition graphene onto different flexible substrates. The transfer method investigated here is fast, simple, and does not require an intermediate transfer membrane, such as polymethylmethacrylate, which needs to be removed afterward. Various substrates of general interest in research and industry were studied in this work, including polytetrafluoroethylene filter membranes, PVC, cellulose nitrate/cellulose acetate filter membranes, polycarbonate, paraffin, polyethylene terephthalate, paper, and cloth. By comparing the properties of these substrates, two critical factors to ensure a successful transfer on bare substrates were identified: the substrate’s hydrophobicity and good contact between the substrate and graphene. For substrates that do not satisfy those requirements, polymethylmethacrylate can be used as a surface modifier or glue to ensure successful transfer. Our results can be applied to facilitate current processes and open up directions for applications of chemical vapor deposition graphene on flexible substrates. A broad range of applications can be envisioned, including fabrication of graphene devices for opto/organic electronics, graphene membranes for gas/liquid separation, and ubiquitous electronics with graphene. PMID:24127582
SHI induced nano track polymer filters and characterization
NASA Astrophysics Data System (ADS)
Vijay, Y. K.
2009-07-01
Swift heavy ion irradiation produces damage in polymers in the form of latent tracks. Latent tracks can be enlarged by etching it in a suitable etchant and thus nuclear track etch membrane can be formed for gas permeation / purification in particular for hydrogen where the molecular size is very small. By applying suitable and controlled etching conditions well defined tracks can be formed for specific applications of the membranes. After etching gas permeation method is used for characterizing the tracks. In the present work polycarbonate (PC) of various thickness were irradiated with energetic ion beam at Inter University Accelerator Centre (IUAC), New Delhi. Nuclear tracks were modified by etching the PC in 6N NaOH at 60 (±1) °C from both sides for different times to produce track etch membranes. At critical etch time the etched pits from both the sides meet a rapid increase in gas permeation was observed. Permeability of hydrogen and carbon dioxide has been measured in samples etched for different times. The latent tracks produced by SHI irradiation in the track etch membranes show enhancement of free volume of the polymer. Nano filters are separation devices for the mixture of gases, different ions in the solution and isotopes and isobars separations. The polymer thin films with controlled porosity finding it self as best choice. However, the permeability and selectivity of these polymer based membrane filters are very important at the nano scale separation. The Swift Heavy Ion (SHI) induced nuclear track etched polymeric films with controlled etching have been attempted and characterized as nano scale filters.
Siontorou, Christina G.
1997-01-01
This paper describes the results of analytical applications of electrochemical biosensors based on bilayer lipid membranes (BLMs) for the automated rapid and sensitive flow monitoring of substrates of hydrolytic enzymes, antigens and triazine herbicides. BLMs, composed of mixtures of egg phosphatidylcholine (egg PC) and dipalmitoylphosphatidic acid (DPPA), were supported on ultrafiltration membranes (glass microfibre or polycarbonate filters) which were found to enhance their stability for flow experiments. The proteins (enzymes, antibodies) were incorporated into a floating lipid matrix at an air-electrolyte interface, and then a casting procedure was used to deliver the lipid onto the filter supports for BLM formation. Injections of the analyte were made into flowing streams of the carrier electrolyte solution and a current transient signal was obtained with a magnitude related to the analyte concentration. Substrates of hydrolytic enzyme reactions (acetylcholine, urea and penicillin) could be determined at the micromolar level with a maximum rate of 220 samples/h, whereas antigens (thyroxin) and triazine herbicides (simazine, atrazine and propazine) could be monitored at the nanomolar level in less than 2 min. The time of appearance of the transient response obtained for herbicides was increased to the order of simazine, atrazine and propazine which has permitted analysis of these triazines in mixtures. PMID:18924789
Koseoglu-Imer, Derya Yuksel; Dizge, Nadir; Karagunduz, Ahmet; Keskinler, Bulent
2011-07-01
The effects of membrane fouling reducers (MFRs) (the cationic polyelectrolyte (CPE) and FeCI(3)) on membrane fouling were studied in a lab-scale jet loop submerged membrane bioreactor (JL-SMBR) system. The optimum dosages of MFRs (CPE dosage=20 mg g(-1)MLSS, FeCI(3) dosage=14 mg g(-1)MLSS) were continuously fed to JL-SMBR system. The soluble and bound EPS concentrations as well as MLSS concentration in the mixed liquor of JL-SMBR were not changed substantially by the addition of MFRs. However, significant differences were observed in particle size and relative hydrophobicity. Filtration tests were performed by using different membrane types (polycarbonate (PC) and nitrocellulose mixed ester (ME)) and various pore sizes (0.45-0.22-0.1 μm). The steady state fluxes (J(ss)) of membranes increased at all membranes after MFRs addition to JL-SMBR. The filtration results showed that MFRs addition was an effective approach in terms of improvement in filtration performance for both membrane types. Copyright © 2011 Elsevier Ltd. All rights reserved.
Qiao, Yuan; Yang, Chuan; Coady, Daniel J; Ong, Zhan Yuin; Hedrick, James L; Yang, Yi-Yan
2012-02-01
The development of biodegradable antimicrobial polymers adds to the toolbox of attractive antimicrobial agents against antibiotic-resistant microbes. To this end, the potential of polycarbonate polymers as such materials were explored. A series of random polycarbonate polymers consisting of monomers MTC-OEt and MTC-CH(2)CH(3)Cl were designed and synthesized using metal-free organocatalytic ring-opening polymerization. Random polycarbonate polymers self-assembled in solution but appeared highly dynamic; such behaviors are desirable as ready disassembly of polymers at the microbial membrane facilitates membrane disruption. Their activities against clinically relevant Gram-positive (Staphylococcus aureus) and Gram-negative bacteria (E.coli and Pseudomonas aeruginosa) revealed that the hydrophobic-hydrophilic composition balance in polymers are important to render antimicrobial potency. Scanning electron microscopy (SEM) studies indicated microbial cell surface damage after treatment with polymers, and confocal microscopy studies also showed entry of FITC-dextran dye in Escherichia coli as a result of membrane disruption. On the other hand, the polymers exhibited minimal toxicity against red blood cells in hemolysis tests. Therefore, these random polycarbonate polymers are promising antimicrobial agents against both Gram-positive and Gram-negative bacteria for various biomedical applications. Copyright © 2011 Elsevier Ltd. All rights reserved.
2013-04-01
precipitation of calcium carbonate in structured templates including microporous polycarbonate membranes and polyethylene foams. Para- meters...polyethylene foam). Microporous polycarbonate membranes and Medium-Density PolyEthylene (MDPE) foam specimens were used as the porous organic...voids in hardened concrete. DOI:10.1520/C624-06. West Conshohocken, PA: ASTM International . www.astm.org. Bersa, L., and M. Liu. 2007. A review on
Large-scale generation of cell-derived nanovesicles
NASA Astrophysics Data System (ADS)
Jo, W.; Kim, J.; Yoon, J.; Jeong, D.; Cho, S.; Jeong, H.; Yoon, Y. J.; Kim, S. C.; Gho, Y. S.; Park, J.
2014-09-01
Exosomes are enclosed compartments that are released from cells and that can transport biological contents for the purpose of intercellular communications. Research into exosomes is hindered by their rarity. In this article, we introduce a device that uses centrifugal force and a filter with micro-sized pores to generate a large quantity of cell-derived nanovesicles. The device has a simple polycarbonate structure to hold the filter, and operates in a common centrifuge. Nanovesicles are similar in size and membrane structure to exosomes. Nanovesicles contain intracellular RNAs ranging from microRNA to mRNA, intracellular proteins, and plasma membrane proteins. The quantity of nanovesicles produced using the device is 250 times the quantity of naturally secreted exosomes. Also, the quantity of intracellular contents in nanovesicles is twice that in exosomes. Nanovesicles generated from murine embryonic stem cells can transfer RNAs to target cells. Therefore, this novel device and the nanovesicles that it generates are expected to be used in exosome-related research, and can be applied in various applications such as drug delivery and cell-based therapy.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Eng, L.A.; Metz, C.B.
1986-09-01
The meaningful detection of antisperm antibody in immunologically infertile females has been confounded by the many methods of assay that exist. With many of these methods there is poor correlation of assay results with infertility. In this report, female rabbits were rendered partially or completely infertile by immunization with sperm fractions. A filter radioassay for antisperm antibody was developed that consists of incubating 10(7) sperm with sperm from immunized rabbits and /sup 14/C-Protein A, a long-lived and versatile indirect radiolabel for many antibodies of the IgG class. The spermatozoa are washed by rapid vacuum filtration on polycarbonate membrane filters insteadmore » of by time-consuming centrifugation. The filters with the collected spermatozoa are then counted in a liquid scintillation counter. Sera from female rabbits isoimmunized with sperm antigens show a highly significant correlation (r = -0.904; p less than 0.001) between assay results and infertility as measured by the percentage of eggs that underwent cleavage after artificial insemination.« less
Simple, benign, aqueous-based amination of polycarbonate surfaces
VanDelinder, Virginia; Wheeler, David R.; Small, Leo J.; ...
2015-03-18
Here we report a simple, safe, environmentally-friendly aqueous method that uses diamines to functionalize a polycarbonate surface with amino groups. We demonstrate the ability of this facile method to serve as a foundation upon which other functionalities may be attached, including anti-fouling coatings and oriented membrane proteins. The use of water as the solvent for the functionalization ensures that solvent induced swelling does not affect the optical or mechanical properties of the polycarbonate.
Taheri, A; Saramad, S; Ghalenoei, S; Setayeshi, S
2014-01-01
A novel x-ray imager based on ZnO nanowires is designed and fabricated. The proposed architecture is based on scintillation properties of ZnO nanostructures in a polycarbonate track-etched membrane. Because of higher refractive index of ZnO nanowire compared to the membrane, the nanowire acts as an optical fiber that prevents the generated optical photons to spread inside the detector. This effect improves the spatial resolution of the imager. The detection quantum efficiency and spatial resolution of the fabricated imager are 11% and <6.8 μm, respectively.
NASA Astrophysics Data System (ADS)
Dewalle, Pascale; Sirven, Jean-Baptiste; Roynette, Audrey; Gensdarmes, François; Golanski, Luana; Motellier, Sylvie
2011-07-01
Nowadays, due to their unique physical and chemical properties, engineered nanoparticles are increasingly used in a variety of industrial sectors. However, questions are raised about the safety of workers who produce and handle these particles. Therefore it is necessary to assess the potential exposure by inhalation of these workers. There is thereby a need to develop a suitable instrumentation which can detect selectively the presence of engineered nanoparticles in the ambient atmosphere. In this paper Laser-Induced Breakdown Spectroscopy (LIBS) is used to meet this target. LIBS can be implemented on site since it is a fast and direct technique which requires no sample preparation. The approach consisted in sampling Fe2O3 and TiO2 nanoparticles on a filter, respectively a mixed cellulose ester membrane and a polycarbonate membrane, and to measure the surface concentration of Fe and Ti by LIBS. Then taking into account the sampling parameters (flow, duration, filter surface) we could calculate a detection limit in volume concentration in the atmosphere. With a sampling at 10 L/min on a 10 cm2 filter during 1 min, we obtained detection limits of 56 μg/m3 for Fe and 22 μg/m3 for Ti. These figures, obtained in real time, are significantly below existing workplace exposure recommendations of the EU-OSHA and of the NIOSH. These results are very encouraging and will be completed in a future work on airborne carbon nanotube detection.
Elliott, D.G.; Barila, T.Y.
1987-01-01
We developed a rapid method for detecting and quantifying the pathogen Renibacterium salmoninarum in coelomic fluid of spring chinook salmon (Oncorhynchus tshawytscha) by concentrating the bacteria on 0.2-μm polycarbonate filters and staining them with specific fluorescein-labeled antibody. Centrifugation of samples and resuspension of the sedimented material in phosphate-buffered saline containing Triton X-100 increased the ease of filtration. Background fluorescence was reduced by counterstaining filters with Eriochrome black T. Postfiltration staining, rinsing, and counterstaining were done in the syringe-mounted filter holders, reducing handling of the filters and possible loss of bacteria. The number of bacteria detected by the filtration – fluorescent antibody technique in a broth culture of R. salmoninarum ranged from 6.7 × 107to7.6 × 107/mL and was slightly higher than that determined by plate count (9.6 × 106/mL). Increasing the sample dilution or decreasing the number of microscope fields examined generally increased the variability of filter counts of R. salmoninarum. Using the filtration – fluorescent antibody technique, we detected the bacterium in the coelomic fluid of 85% of spawning female spring chinook salmon sampled from a hatchery population.
Shlyonsky, Vadim
2013-12-01
In the present article, a novel model of artificial membranes that provides efficient assistance in teaching the origins of diffusion potentials is proposed. These membranes are made of polycarbonate filters fixed to 12-mm plastic rings and then saturated with a mixture of creosol and n-decane. The electrical resistance and potential difference across these membranes can be easily measured using a low-cost volt-ohm meter and home-made Ag/AgCl electrodes. The advantage of the model is the lack of ionic selectivity of the membrane, which can be modified by the introduction of different ionophores to the organic liquid mixture. A membrane treated with the mixture containing valinomycin generates voltages from -53 to -25 mV in the presence of a 10-fold KCl gradient (in to out) and from -79 to -53 mV in the presence of a bi-ionic KCl/NaCl gradient (in to out). This latter bi-ionic gradient potential reverses to a value from +9 to +20 mV when monensin is present in the organic liquid mixture. Thus, the model can be build stepwise, i.e., all factors leading to the development of diffusion potentials can be introduced sequentially, helping students to understand the quantitative relationships of ionic gradients and differential membrane permeability in the generation of cell electrical signals.
Track-Etched Magnetic Micropores for Immunomagnetic Isolation of Pathogens
Muluneh, Melaku; Shang, Wu
2014-01-01
A microfluidic chip is developed to selectively isolate magnetically tagged cells from heterogeneous suspensions, the track-etched magnetic micropore (TEMPO) filter. The TEMPO consists of an ion track-etched polycarbonate membrane coated with soft magnetic film (Ni20Fe80). In the presence of an applied field, provided by a small external magnet, the filter becomes magnetized and strong magnetic traps are created along the edges of the micropores. In contrast to conventional microfluidics, fluid flows vertically through the porous membrane allowing large flow rates while keeping the capture rate high and the chip compact. By utilizing track-etching instead of conventional semiconductor fabrication, TEMPOs can be fabricated with microscale pores over large areas A > 1 cm2 at little cost (< 5 ¢ cm−2). To demonstrate the utility of this platform, a TEMPO with 5 μm pore size is used to selectively and rapidly isolate immunomagnetically targeted Escherichia coli from heterogeneous suspensions, demonstrating enrichment of ζ > 500 at a flow rate of Φ = 5 mL h−1. Furthermore, the large density of micropores (ρ = 106 cm−2) allows the TEMPO to sort E. coli from unprocessed environmental and clinical samples, as the blockage of a few pores does not significantly change the behavior of the device. PMID:24535921
76 FR 36386 - Petition for Rulemaking Submitted by Annette User on Behalf of GE Osmonics, Inc.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-06-22
... quantities of polymer (polycarbonate or polyester) track etch (PCTE) membranes that have been irradiated with... State. (f) Polymer track etch membrane containing mixed fission products in individual quantities, each...
Chemistry of Airborne Particulate Matter in the Western Plains of Texas Using PIXE Analysis
USDA-ARS?s Scientific Manuscript database
Aerosol samples on polycarbonate filters were collected daily (for 24 hour periods) over several years in Lubbock, Reese Center, and Big Spring in the Southern High Plains region of western Texas, a region known for frequent dust storms. Twenty-seven filter samples representing a variety of particle...
NASA Astrophysics Data System (ADS)
Gasparac, Rahela
Chapter 1 provides background information on the template synthesis of nanomaterials. A description of the types of membranes used for template synthesis is given. Different chemistries that have been used to prepare template-synthesized structures are provided. Template synthesis has been used to prepare some important nanostructures. Polycarbonate membranes were used to prepare gold nanotubes using electroless gold template method. SiO2 nano-test-tubes were made by dipping the alumina template membrane in the sol and heating. An introduction to conductive is presented here as well. Chapter 2 describes the transport of DNA molecules through nanopore membranes. We are interested in how pore diameter of the membrane affects rate and selectivity of DNA transport of different size and charge. Commercially available microporous polycarbonate membrane filters were used. DNA chains can be driven through the nanopore via the electrokinetic transport processes of electrophoresis and electroolsmotic flow, as well as by diffusion. To our knowledge, there have been no quantitative studies of the relative importance of the electrokinetic and diffusive components for DNA transport in a nanopore system. Chapter 3 describes a sol-gel template synthesis process that is used to produce silica nano-test-tubes within the pores of alumina templates. These silica nano-test-tubes are important because of the ease with which nearly any desired chemical or biochemical reagent can be covalently attached to their inside and outside surfaces. Inner and outer surfaces of the silica nano-test-tubes were functionalized using well-known silane chemistry. Green fluorescent silane was attached to the inner surfaces. The outer SiO 2 nano-test-tube surfaces were antibody functionalized using aldehyde methoxysilane linker. One of our key long-range objective is to develop nanotube technology for delivering biomolecules (e.g., DNA) to living cells. Chapter 4 focuses on the mechanism by which polyaniline (PANI) films passivate stainless steel surfaces in highly corrosive H2SO 4 solution. A variety of experimental methods including measurements of the open circuit potential, Auger depth profiling, and the scanning reference electrode technique (SRET) was used. These studies have shown that passivation is achieved because the oxidized and protically-doped emeraldine-salt form of PANI holds the potential of the underlying stainless steel electrode in the passive region. Because of this electrostatic mechanism of corrosion inhibition, the entire stainless steel surface does not have to be coated with PANI in order to achieve passivation.
Comparison of direct and indirect methods of measuring airborne chrysotile fibre concentration.
Eypert-Blaison, Celine; Veissiere, Sylvie; Rastoix, Olivier; Kauffer, Edmond
2010-01-01
Transmission electron microscopy observations most frequently form a basis for estimating asbestos fibre concentration in the environment and in buildings with asbestos-containing materials. Sampled fibres can be transferred to microscope grids by applying either a direct [ISO (1995) Draft International ISO/DIS 10312. Ambient air. Determination of asbestos fibres. Direct transfer transmission electron microscopy procedure. Geneva, Switzerland: International Standardization Organization] or an indirect [AFNOR (1996) Détermination de la concentration en fibres d'amiante par microscopie électronique à transmission-Méthode indirecte. Cedex, France: AFNOR, p. 42; ISO (1997) Draft International ISO/DIS 13794. Ambient air. Determination of asbestos fibres. Indirect-transfer transmission electron microscopy procedure. Geneva, Switzerland: International Standardization Organization] method. In the latter case, ISO Standard 13794 recommends filtering calcination residues either on a polycarbonate (PC) filter (PC indirect method) or on a cellulose ester (CE) membrane (CE indirect method). The PC indirect method requires that fibres deposited on a PC filter be covered by a carbon layer, whereas in the CE indirect method, the CE membrane has to be directly processed using a method described in ISO Standard 10312. The purpose of this study was to compare results obtained using, on the one hand, direct preparation methods and, on the other hand, PC indirect or CE indirect methods, for counting asbestos fibres deposited on filters as a result of liquid filtration or air sampling. In direct method-based preparation, we observed that an etching time of 6-14 min does not affect the measured densities, except for fibres <1 microm deposited by liquid filtration. Moreover, in all cases, the direct method gives higher densities than the PC indirect method because of possible fibre disappearance when using the carbon evaporator implemented in the PC indirect method. The CE membrane used for sample preparation in the CE indirect method is collapsed prior to passing it through the carbon evaporator, so the fibres are less likely to disappear at this stage. We then note that the resulting fibre densities for chrysotile-loaded filters prepared using the direct method are close to those obtained with filters prepared using the CE indirect method. Our study therefore shows that, under the implemented experimental conditions, the PC and CE indirect preparation methods described in ISO Standard 13794 are not equivalent.
Prototyping Energy Storage Components for Hybrid Power Source
2009-12-11
from suitable nanoporous ceramic ( anodized aluminum oxide – AAO ) and polymer (polycarbonate - PC, polyethylene terephtalate - PET) membranes . Metal...of NUC technology: a) sketch of structure, b) SEM image of membrane . The alumina membranes can be easily and inexpensively fabricated via anodization ...of aluminum foil. The pores are formed by self-assembly via pitting and reprecipation of metal oxide . Motivation The work is motivated by the
Adhikari, Atin; Yermakov, Michael; Indugula, Reshmi; Reponen, Tiina; Driks, Adam; Grinshpun, Sergey A
2016-05-01
Destruction of bioweapon facilities due to explosion or fire could aerosolize highly pathogenic microorganisms. The post-event air quality assessment is conducted through air sampling. A bioaerosol sample (often collected on a filter for further culture-based analysis) also contains combustion products, which may influence the microbial culturability and, thus, impact the outcome. We have examined the interaction between spores deposited on collection filters using two simulants of Bacillus anthracis [B. thuringiensis (Bt) and B. atrophaeus (referred to as BG)] and incoming combustion products of Al as well as Mg and B·Ti (common ingredient of metalized explosives). Spores extracted from Teflon, polycarbonate, mixed cellulose ester (MCE), and gelatin filters (most common filter media for bioaerosol sampling), which were exposed to combustion products during a short-term sampling, were analyzed by cultivation. Surprisingly, we observed that aluminum combustion products enhanced the culturability of Bt (but not BG) spores on Teflon filters increasing the culturable count by more than an order of magnitude. Testing polycarbonate and MCE filter materials also revealed a moderate increase of culturability although gelatin did not. No effect was observed with either of the two species interacting on either filter media with products originated by combustion of Mg and B·Ti. Sample contamination, spore agglomeration, effect of a filter material on the spore survival, changes in the spore wall ultrastructure and germination, as well as other factors were explored to interpret the findings. The study raises a question about the reliability of certain filter materials for collecting airborne bio-threat agents in combustion environments. Copyright © 2016 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Mohammadian-Behbahani, Mohammad-Reza; Saramad, Shahyar; Mohammadi, Mohammad
2017-05-01
A combination of Finite Difference Time Domain (FDTD) and Monte Carlo (MC) methods is proposed for simulation and analysis of ZnO microscintillators grown in polycarbonate membrane. A planar 10 keV X-ray source irradiating the detector is simulated by MC method, which provides the amount of absorbed X-ray energy in the assembly. The transport of generated UV scintillation light and its propagation in the detector was studied by the FDTD method. Detector responses to different probable scintillation sites and under different energies of X-ray source from 10 to 25 keV are reported. Finally, the tapered geometry for the scintillators is proposed, which shows enhanced spatial resolution in comparison to cylindrical geometry for imaging applications.
NASA Astrophysics Data System (ADS)
Jonas, A. M.; Legras, R.; Ferain, E.
1998-03-01
Nanoporous track-etched membranes with narrow pore size distributions and average pore size diameters tunable from 100 to 1000 Åare produced by the chemical etching of latent tracks in polymer films after irradiation by a beam of accelerated heavy ions. Nanoporous membranes are used for highly demanding filtration purposes, or as templates to obtain metallic or polymeric nanowires (L. Piraux et al., Nucl. Instr. Meth. Phys. Res. 1997, B131, 357). Such applications call for developments in nanopore size characterization techniques. In this respect, we report on the characterization by small-angle X-ray scattering (SAXS) of nanopore size distribution (nPSD) in polycarbonate track-etched membranes. The obtention of nPSD requires inverting an ill-conditioned inhomogeneous equation. We present different numerical routes to overcome the amplification of experimental errors in the resulting solutions, including a regularization technique allowing to obtain the nPSD without a priori knowledge of its shape. The effect of deviations from cylindrical pore shape on the resulting distributions are analyzed. Finally, SAXS results are compared to results obtained by electron microscopy and conductometry.
The present situation of the irradiation application industry and irradiation facilities in Japan
NASA Astrophysics Data System (ADS)
Mizusawa, K.; Baba, T.
2003-08-01
The irradiation application industry and irradiation facilities in Japan have been making slow but steady progress for the past 2-3 years. Beside conventional applications, new ones such as carbon fibers and membrane filters have come into the market. There are a lot of new applications about to emerge. PE tubing, already is in the European market, is being evaluated by end users in Japan. Cleaning of dioxin in exhaust gas was successfully tested at a pilot plant. Cross-linked PTFE and polyamide are waiting customers' evaluations as an engineering plastic. Surface cross-linking of artificial polycarbonate teeth has yielded remarkable experimental results. Cross-linking of polycaprolactone will be useful for biodegradable products. Being aware of the future growth of irradiation industry, contract service providers opened new facilities or increased their capability. Beside in-house facilities, there are now three Co-60 facilities and nine EB facilities available for contract irradiation in Japan.
Evaluation on biocompatibility of biomedical polyurethanes with different hard segment contents
NASA Astrophysics Data System (ADS)
Ma, Dai-Wei; Zhu, Rong; Wang, Yi-Yu; Zhang, Zong-Rui; Wang, Xin-Yu
2015-12-01
In this paper, polyurethane (PU) materials with different contents of hard segment (20%, 25%, 30%) were prepared based on hexamethylene diisocyanate and polycarbonate diols by solution polymerization. The obtained polycarbonate-urethane (PCU) elastomers were characterized by very good hydrophobic property and excellent resistance to hydrolysis. Hemolysis, recalification time and platelet-rich plasma adhesion were used to evaluate the blood compatibility of the materials. L929 cells cultured with leach liquor of these PU membranes were selected to perform the cytotoxicity experiments. The results indicate that the hemolysis rates of PU membranes are all less than 5%, which can meet the requirement of the national standards for biomaterials. However, compared with 20% and 30% groups, the recalification time of the sample containing 25% hard segment is longer, while the number of platelet adhesion is less. Additionally, cells cultured in the leach liquor of PU membranes with 25% hard segment proliferated relatively more thriving, meaning that this proportion of the material has the lowest cytotoxicity.
Selective transport of nutrients via the rhizoids of the water mold Blastocladiella emersonii.
Kropf, D L; Harold, F M
1982-01-01
Previous work in this laboratory demonstrated that the rhizoids of Blastocladiella emersonii grow chemotropically toward a source of Pi and thus provided preliminary evidence that, in addition to serving as a holdfast, the rhizoids absorb nutrients. To further examine the role of the rhizoids in nutrient uptake, we devised a technique to introduce a barrier between the rhizoids and the thallus to that these cell compartments could be studied independently. Cells were grown on polycarbonate membrane filters in such a way that all of the thalli were on one side of the filter and essentially all of the rhizoids were on the opposite side. Nutrient uptake into the rhizoids and the thallus was measured by floating the filters bearing cells on radioactive medium so that only one side of the filter contacted the label. Mineral oil was used to block the diffusion of the label through the unfilled pores in the filter. This technique permitted us to establish clearly that the rhizoids absorb all seven of the nutrients tested. In addition, we found that some nutrients, specifically Pi and amino acids, appeared to be preferentially taken up via the rhizoids, whereas K+, Rb+, and Ca2+ entered the thallus and rhizoids equally. Cells grown in the presence of the microtubule synthesis inhibitors nocodazole and carbendazim elaborated only a stunted rhizoid system, so we examined their ability to accumulate the two classes of compounds. As expected, these cells were severely inhibited in Pi and amino acid uptake but retained normal uptake of K+, Rb+, and Ca2+. Images PMID:7085568
Selective transport of nutrients via the rhizoids of the water mold Blastocladiella emersonii.
Kropf, D L; Harold, F M
1982-07-01
Previous work in this laboratory demonstrated that the rhizoids of Blastocladiella emersonii grow chemotropically toward a source of Pi and thus provided preliminary evidence that, in addition to serving as a holdfast, the rhizoids absorb nutrients. To further examine the role of the rhizoids in nutrient uptake, we devised a technique to introduce a barrier between the rhizoids and the thallus to that these cell compartments could be studied independently. Cells were grown on polycarbonate membrane filters in such a way that all of the thalli were on one side of the filter and essentially all of the rhizoids were on the opposite side. Nutrient uptake into the rhizoids and the thallus was measured by floating the filters bearing cells on radioactive medium so that only one side of the filter contacted the label. Mineral oil was used to block the diffusion of the label through the unfilled pores in the filter. This technique permitted us to establish clearly that the rhizoids absorb all seven of the nutrients tested. In addition, we found that some nutrients, specifically Pi and amino acids, appeared to be preferentially taken up via the rhizoids, whereas K+, Rb+, and Ca2+ entered the thallus and rhizoids equally. Cells grown in the presence of the microtubule synthesis inhibitors nocodazole and carbendazim elaborated only a stunted rhizoid system, so we examined their ability to accumulate the two classes of compounds. As expected, these cells were severely inhibited in Pi and amino acid uptake but retained normal uptake of K+, Rb+, and Ca2+.
Environmental scanning electron microscope imaging examples related to particle analysis.
Wight, S A; Zeissler, C J
1993-08-01
This work provides examples of some of the imaging capabilities of environmental scanning electron microscopy applied to easily charged samples relevant to particle analysis. Environmental SEM (also referred to as high pressure or low vacuum SEM) can address uncoated samples that are known to be difficult to image. Most of these specimens are difficult to image by conventional SEM even when coated with a conductive layer. Another area where environmental SEM is particularly applicable is for specimens not compatible with high vacuum, such as volatile specimens. Samples from which images were obtained that otherwise may not have been possible by conventional methods included fly ash particles on an oiled plastic membrane impactor substrate, a one micrometer diameter fiber mounted on the end of a wire, uranium oxide particles embedded in oil-bearing cellulose nitrate, teflon and polycarbonate filter materials with collected air particulate matter, polystyrene latex spheres on cellulosic filter paper, polystyrene latex spheres "loosely" sitting on a glass slide, and subsurface tracks in an etched nuclear track-etch detector. Surface charging problems experienced in high vacuum SEMs are virtually eliminated in the low vacuum SEM, extending imaging capabilities to samples previously difficult to use or incompatible with conventional methods.
Brasel, T L; Douglas, D R; Wilson, S C; Straus, D C
2005-01-01
Highly respirable particles (diameter, <1 microm) constitute the majority of particulate matter found in indoor air. It is hypothesized that these particles serve as carriers for toxic compounds, specifically the compounds produced by molds in water-damaged buildings. The presence of airborne Stachybotrys chartarum trichothecene mycotoxins on particles smaller than conidia (e.g., fungal fragments) was therefore investigated. Cellulose ceiling tiles with confluent Stachybotrys growth were placed in gas-drying containers through which filtered air was passed. Exiting particulates were collected by using a series of polycarbonate membrane filters with decreasing pore sizes. Scanning electron microscopy was employed to determine the presence of conidia on the filters. A competitive enzyme-linked immunosorbent assay (ELISA) specific for macrocyclic trichothecenes was used to analyze filter extracts. Cross-reactivity to various mycotoxins was examined to confirm the specificity. Statistically significant (P < 0.05) ELISA binding was observed primarily for macrocyclic trichothecenes at concentrations of 50 and 5 ng/ml and 500 pg/ml (58.4 to 83.5% inhibition). Of the remaining toxins tested, only verrucarol and diacetylverrucarol (nonmacrocyclic trichothecenes) demonstrated significant binding (18.2 and 51.7% inhibition, respectively) and then only at high concentrations. The results showed that extracts from conidium-free filters demonstrated statistically significant (P < 0.05) antibody binding that increased with sampling time (38.4 to 71.9% inhibition, representing a range of 0.5 to 4.0 ng/ml). High-performance liquid chromatography analysis suggested the presence of satratoxin H in conidium-free filter extracts. These data show that S. chartarum trichothecene mycotoxins can become airborne in association with intact conidia or smaller particles. These findings may have important implications for indoor air quality assessment.
Analysis of Cosmic Spherule Candidates from the Kwajalein Micrometeorite Collection
NASA Technical Reports Server (NTRS)
Wozniakiewicz, P. J.; Price, M. C.; Bradley, J. P.; Ishii, H. A.; Russell, S. S.; Zolensky, M. E.; Brownlee, D. E.
2015-01-01
The Kwajalein micrometeorite collection utilised high volume air samplers fitted with 5 micrometer laser-etched polycarbonate membrane filters to capture particles directly from the atmosphere. The filters were changed weekly over several months throughout 2011/12, providing the opportunity to investigate the contemporary flux of micrometeorites. We recently reported the results of our initial survey of cosmic spherule-like particles on several of these filters. We identified three main groups of particle based on bulk compositions: 1. Silicate spherules rich in Mg, Ca and Fe, 2. Silicate spherules rich in Al, Ca, K and/or Na and 3. Fe-rich spherules. Abundances appeared to change over time suggesting links with celestial activity (e.g. meteor showers), however, spherules similar to groups 2 and 3 can be produced by terrestrial and anthropogenic activity (e.g. volcanic microspherules exhibit similar compositions to group 2 spherules and metallic spherules similar to those of group 3 can be formed during fuel combustion). We are now studying the internal structures and chemistries of these spherules and comparing against cosmic spherules identified in other collections to confrim their origins and further contrain the contemporary micrometeorite flux. Particles are being picked, embedded in resin and polished through to reveal their interiors. Here we will describe our ongoing analyses of these particles via SEM. We will also introduce our new collection using this method that is currently being performed in the Antarctic.
Sobel, Nicolas; Lukas, Manuela; Spende, Anne; Stühn, Bernd; Trautmann, Christina
2015-01-01
Summary Polycarbonate etched ion-track membranes with about 30 µm long and 50 nm wide cylindrical channels were conformally coated with SiO2 by atomic layer deposition (ALD). The process was performed at 50 °C to avoid thermal damage to the polymer membrane. Analysis of the coated membranes by small angle X-ray scattering (SAXS) reveals a homogeneous, conformal layer of SiO2 in the channels at a deposition rate of 1.7–1.8 Å per ALD cycle. Characterization by infrared and X-ray photoelectron spectroscopy (XPS) confirms the stoichiometric composition of the SiO2 films. Detailed XPS analysis reveals that the mechanism of SiO2 formation is based on subsurface crystal growth. By dissolving the polymer, the silica nanotubes are released from the ion-track membrane. The thickness of the tube wall is well controlled by the ALD process. Because the track-etched channels exhibited diameters in the range of nanometres and lengths in the range of micrometres, cylindrical tubes with an aspect ratio as large as 3000 have been produced. PMID:25821688
NASA Astrophysics Data System (ADS)
Pocock, Kyall J.; Gao, Xiaofang; Wang, Chenxi; Priest, Craig; Prestidge, Clive A.; Mawatari, Kazuma; Kitamori, Takehiko; Thierry, Benjamin
2015-12-01
The integration of microfluidics with living biological systems has paved the way to the exciting concept of "organson- a-chip", which aims at the development of advanced in vitro models that replicate the key features of human organs. Glass based devices have long been utilised in the field of microfluidics but the integration of alternative functional elements within multi-layered glass microdevices, such as polymeric membranes, remains a challenge. To this end, we have extended a previously reported approach for the low-temperature bonding of glass devices that enables the integration of a functional polycarbonate porous membrane. The process was initially developed and optimised on specialty low-temperature bonding equipment (μTAS2001, Bondtech, Japan) and subsequently adapted to more widely accessible hot embosser units (EVG520HE Hot Embosser, EVG, Austria). The key aspect of this method is the use of low temperatures compatible with polymeric membranes. Compared to borosilicate glass bonding (650 °C) and quartz/fused silica bonding (1050 °C) processes, this method maintains the integrity and functionality of the membrane (Tg 150 °C for polycarbonate). Leak tests performed showed no damage or loss of integrity of the membrane for up to 150 hours, indicating sufficient bond strength for long term cell culture. A feasibility study confirmed the growth of dense and functional monolayers of Caco-2 cells within 5 days.
Low-temperature bonding process for the fabrication of hybrid glass-membrane organ-on-a-chip devices
NASA Astrophysics Data System (ADS)
Pocock, Kyall J.; Gao, Xiaofang; Wang, Chenxi; Priest, Craig; Prestidge, Clive A.; Mawatari, Kazuma; Kitamori, Takehiko; Thierry, Benjamin
2016-10-01
The integration of microfluidics with living biological systems has paved the way to the exciting concept of "organs-on-a-chip," which aims at the development of advanced in vitro models that replicate the key features of human organs. Glass-based devices have long been utilized in the field of microfluidics but the integration of alternative functional elements within multilayered glass microdevices, such as polymeric membranes, remains a challenge. To this end, we have extended a previously reported approach for the low-temperature bonding of glass devices that enables the integration of a functional polycarbonate porous membrane. The process was initially developed and optimized on specialty low-temperature bonding equipment (μTAS2001, Bondtech, Japan) and subsequently adapted to more widely accessible hot embosser units (EVG520HE Hot Embosser, EVG, Austria). The key aspect of this method is the use of low temperatures compatible with polymeric membranes. Compared to borosilicate glass bonding (650°C) and quartz/fused silica bonding (1050°C) processes, this method maintains the integrity and functionality of the membrane (Tg 150°C for polycarbonate). Leak tests performed showed no damage or loss of integrity of the membrane for up to 150 h, indicating sufficient bond strength for long-term cell culture. A feasibility study confirmed the growth of dense and functional monolayers of Caco-2 cells within 5 days.
NASA Astrophysics Data System (ADS)
Engström, J. E.; Leck, C.
2011-08-01
The presented filter-based optical method for determination of soot (light absorbing carbon or Black Carbon, BC) can be implemented in the field under primitive conditions and at low cost. This enables researchers with small economical means to perform monitoring at remote locations, especially in the Asia where it is much needed. One concern when applying filter-based optical measurements of BC is that they suffer from systematic errors due to the light scattering of non-absorbing particles co-deposited on the filter, such as inorganic salts and mineral dust. In addition to an optical correction of the non-absorbing material this study provides a protocol for correction of light scattering based on the chemical quantification of the material, which is a novelty. A newly designed photometer was implemented to measure light transmission on particle accumulating filters, which includes an additional sensor recording backscattered light. The choice of polycarbonate membrane filters avoided high chemical blank values and reduced errors associated with length of the light path through the filter. Two protocols for corrections were applied to aerosol samples collected at the Maldives Climate Observatory Hanimaadhoo during episodes with either continentally influenced air from the Indian/Arabian subcontinents (winter season) or pristine air from the Southern Indian Ocean (summer monsoon). The two ways of correction (optical and chemical) lowered the particle light absorption of BC by 63 to 61 %, respectively, for data from the Arabian Sea sourced group, resulting in median BC absorption coefficients of 4.2 and 3.5 Mm-1. Corresponding values for the South Indian Ocean data were 69 and 97 % (0.38 and 0.02 Mm-1). A comparison with other studies in the area indicated an overestimation of their BC levels, by up to two orders of magnitude. This raises the necessity for chemical correction protocols on optical filter-based determinations of BC, before even the sign on the radiative forcing based on their effects can be assessed.
Effects of Phase Separation Behavior on Morphology and Performance of Polycarbonate Membranes.
Idris, Alamin; Man, Zakaria; Maulud, Abdulhalim S; Khan, Muhammad Saad
2017-04-05
The phase separation behavior of bisphenol-A-polycarbonate (PC), dissolved in N -methyl-2-pyrrolidone and dichloromethane solvents in coagulant water, was studied by the cloud point method. The respective cloud point data were determined by titration against water at room temperature and the characteristic binodal curves for the ternary systems were plotted. Further, the physical properties such as viscosity, refractive index, and density of the solution were measured. The critical polymer concentrations were determined from the viscosity measurements. PC/NMP and PC/DCM membranes were fabricated by the dry-wet phase inversion technique and characterized for their morphology, structure, and thermal stability using field emission scanning electron microscopy, Fourier transform infrared spectroscopy, and thermogravimetric analysis, respectively. The membranes' performances were tested for their permeance to CO₂, CH₄, and N₂ gases at 24 ± 0.5 °C with varying feed pressures from 2 to 10 bar. The PC/DCM membranes appeared to be asymmetric dense membrane types with appreciable thermal stability, whereas the PC/NMP membranes were observed to be asymmetric with porous structures exhibiting 4.18% and 9.17% decrease in the initial and maximum degradation temperatures, respectively. The ideal CO₂/N₂ and CO₂/CH₄ selectivities of the PC/NMP membrane decreased with the increase in feed pressures, while for the PC/DCM membrane, the average ideal CO₂/N₂ and CO₂/CH₄ selectivities were found to be 25.1 ± 0.8 and 21.1 ± 0.6, respectively. Therefore, the PC/DCM membranes with dense morphologies are appropriate for gas separation applications.
Instrumental neutron activation analysis for studying size-fractionated aerosols
NASA Astrophysics Data System (ADS)
Salma, Imre; Zemplén-Papp, Éva
1999-10-01
Instrumental neutron activation analysis (INAA) was utilized for studying aerosol samples collected into a coarse and a fine size fraction on Nuclepore polycarbonate membrane filters. As a result of the panoramic INAA, 49 elements were determined in an amount of about 200-400 μg of particulate matter by two irradiations and four γ-spectrometric measurements. The analytical calculations were performed by the absolute ( k0) standardization method. The calibration procedures, application protocol and the data evaluation process are described and discussed. They make it possible now to analyse a considerable number of samples, with assuring the quality of the results. As a means of demonstrating the system's analytical capabilities, the concentration ranges, median or mean atmospheric concentrations and detection limits are presented for an extensive series of aerosol samples collected within the framework of an urban air pollution study in Budapest. For most elements, the precision of the analysis was found to be beyond the uncertainty represented by the sampling techniques and sample variability.
Simon, N.S.; Kennedy, M.M.; Massoni, C.S.
1985-01-01
Field and laboratory evaluations were made of a simple, inexpensive diffusion-controlled sampler with ports on two sides at each interval which incorporates 0.2-??m polycarbonate membrane to filter samples in situ. Monovalent and divalent ions reached 90% of equilibrium between sampler contents and the external solution within 3 and 6 hours, respectively. Sediment interstitial water chemical gradients to depths of tens of centimeters were obtained within several days after placement. Gradients were consistent with those determined from interstitial water obtained by centrifugation of adjacent sediment. Ten milliliter sample volumes were collected at 1-cm intervals to determine chemical gradients and dissolved oxygen profiles at depth and at the interface between the sediment and water column. The flux of dissolved species, including oxygen, across the sediment-water interface can be assessed more accurately using this sampler than by using data collected from benthic cores. ?? 1985 Dr W. Junk Publishers.
Shin, Jae-Won; Jo, Sang-Hee; Kim, Ki-Hyun; Song, Hee-Nam; Kang, Chang-Hee; Bolan, Nanthi; Hong, Jongki
2018-05-04
This study investigated the emission characteristics of glass particles resulting from smoking electronic cigarettes (ECs). First, the most suitable filter for the collection of glass particles was explored by examining the performance (reliability) of various types of filters. A polycarbonate filter was determined as the optimum choice to collect glass particles in EC aerosol. A cartomizer was filled with EC refill solution composed of an equal volume of propylene glycol (PG) and vegetable glycol (VG). To simulate the potential conditions for glass particle emission, EC vaped aerosols were collected at three distinctive puffing intervals: (1) 0-10 puffs, (2) 101-110 puffs, and (3) 201-210 puffs (flow rate of 1 L min -1 , 2 s per puff, and 10 puffs per sample). Glass particles were observed as early as after 100 times puffing from certain products, while after 200 from others. Thus, glass particles were generated by increasing the number of puffs and usage of the EC cartomizer. The analysis of glass particles collected onto polycarbonate filters by scanning electron microscopy (SEM)/energy dispersive X-ray spectroscopy (EDS) confirmed the presence of glass particles in samples collected after puffing 100-200 times. The study demonstrated that the possibility of glass particle emissions from the EC device increased considerably with the increasing number of total puffs. Copyright © 2018 Elsevier Inc. All rights reserved.
DEVELOPMENT OF A SAMPLING PROCEDURE FOR LARGE NITROGEN- AND SULFUR-BEARING AEROSOLS
A single-stage impactor was modified to utilize a removable TFE impaction surface mounted on the end of an annular denuder. hen used with a polycarbonate filter coated with silicone oil, its cut point was 2.5 um and bounce was <1% for 8-um particles. ignificant bounce occurred wi...
USDA-ARS?s Scientific Manuscript database
The objective of this study was to fill in additional knowledge gaps with respect to the extraction, storage, and analysis of airborne endotoxin, with a specific focus on samples from a dairy production facility. We utilized polycarbonate filters to collect total airborne endotoxins, sonication as ...
Wang, Xiaodan; Yamaguchi, Nobuyasu; Someya, Takashi; Nasu, Masao
2007-10-01
The micro-colony method was used to enumerate viable bacteria in composts. Cells were vacuum-filtered onto polycarbonate filters and incubated for 18 h on LB medium at 37 degrees C. Bacteria on the filters were stained with SYBR Green II, and enumerated using a newly developed micro-colony auto counting system which can automatically count micro-colonies on half the area of the filter within 90 s. A large number of bacteria in samples retained physiological activity and formed micro-colonies within 18 h, whereas most could not form large colonies on conventional media within 1 week. The results showed that this convenient technique can enumerate viable bacteria in compost rapidly for its efficient quality control.
Effects of Phase Separation Behavior on Morphology and Performance of Polycarbonate Membranes
Idris, Alamin; Man, Zakaria; Maulud, Abdulhalim S.; Khan, Muhammad Saad
2017-01-01
The phase separation behavior of bisphenol-A-polycarbonate (PC), dissolved in N-methyl-2-pyrrolidone and dichloromethane solvents in coagulant water, was studied by the cloud point method. The respective cloud point data were determined by titration against water at room temperature and the characteristic binodal curves for the ternary systems were plotted. Further, the physical properties such as viscosity, refractive index, and density of the solution were measured. The critical polymer concentrations were determined from the viscosity measurements. PC/NMP and PC/DCM membranes were fabricated by the dry-wet phase inversion technique and characterized for their morphology, structure, and thermal stability using field emission scanning electron microscopy, Fourier transform infrared spectroscopy, and thermogravimetric analysis, respectively. The membranes’ performances were tested for their permeance to CO2, CH4, and N2 gases at 24 ± 0.5 °C with varying feed pressures from 2 to 10 bar. The PC/DCM membranes appeared to be asymmetric dense membrane types with appreciable thermal stability, whereas the PC/NMP membranes were observed to be asymmetric with porous structures exhibiting 4.18% and 9.17% decrease in the initial and maximum degradation temperatures, respectively. The ideal CO2/N2 and CO2/CH4 selectivities of the PC/NMP membrane decreased with the increase in feed pressures, while for the PC/DCM membrane, the average ideal CO2/N2 and CO2/CH4 selectivities were found to be 25.1 ± 0.8 and 21.1 ± 0.6, respectively. Therefore, the PC/DCM membranes with dense morphologies are appropriate for gas separation applications. PMID:28379173
The federal standard for the presence of asbestos in drinking water mandates the use of transmission electron microscopy (TEM) as the only acceptable testing method. The July 17, 1992 Federal Register (57 FR 31839, Section 141.23(k)(4)) specifies that the analysis for as...
Lee, Sang Jin; Choi, Jin San; Park, Ki Suk; Khang, Gilson; Lee, Young Moo; Lee, Hai Bang
2004-08-01
Response of different types of cells on materials is important for the applications of tissue engineering and regenerative medicine. It is recognized that the behavior of the cell adhesion, proliferation, and differentiation on materials depends largely on surface characteristics such as wettability, chemistry, charge, rigidity, and roughness. In this study, we examined the behavior of MG63 osteoblast-like cells cultured on a polycarbonate (PC) membrane surfaces with different micropore sizes (0.2-8.0 microm in diameter). Cell adhesion and proliferation to the PC membrane surfaces were determined by cell counting and MTT assay. The effect of surface micropore on the MG63 cells was evaluated by cell morphology, protein content, and alkaline phosphatase (ALP) specific activity. It seems that the cell adhesion and proliferation were progressively inhibited as the PC membranes had micropores with increasing size, probably due to surface discontinuities produced by track-etched pores. Increasing micropore size of the PC membrane results in improved protein synthesis and ALP specific activity in isolated cells. There was a statistically significant difference (P<0.05) between different micropore sizes. The MG63 cells also maintained their phenotype under conditions that support a round cell shape. RT-PCR analysis further confirmed the osteogenic phenotype of the MG63 cells onto the PC membranes with different micropore sizes. In results, as micropore size is getting larger, cell number is reduced and cell differentiation and matrix production is increased. This study demonstrated that the surface topography plays an important role for phenotypic expression of the MG63 osteoblast-like cells.
Bye, E; Føreland, S; Lundgren, L; Kruse, K; Rønning, R
2009-06-01
The purpose of the present investigation was to establish a method for the determination of airborne respirable non-fibrous silicon carbide (SiC). The main application is within the industrial production of SiC. Due to the complex airborne aerosol mixture of crystalline compounds in the SiC industry, X-ray powder diffractometry was selected as the most appropriate method. Without any international standard material for the respirable fraction of non-fibrous SiC, pure and suitable products from three SiC plants in Norway were selected. These products have a median particle diameter in the range 4.4-5.1 mum. The method is based on thin sample technique, with the dust deposited on a polycarbonate filter. Absorption correction is done by standard procedures with the use of a silver filter, situated below the polycarbonate filter. The diffraction line used for quantitative determination was selected carefully. This was done to avoid interferences from quartz, cristobalite, and graphite, which all are airborne components present in the atmosphere during the industrial process. The instrumental limit of detection for the method is 12 microg. This method has been used to determine airborne non-fibrous SiC in a comprehensive ongoing project in the Norwegian SiC industry for further epidemiological studies. The method is fully applicable for compliance work.
Landi, Marco; Guidi, Lucia; Pardossi, Alberto; Tattini, Massimiliano; Gould, Kevin S
2014-11-01
Boron (B) toxicity is an important agricultural problem in arid environments. Excess edaphic B compromises photosynthetic efficiency, limits growth and reduces crop yield. However, some purple-leafed cultivars of sweet basil (Ocimum basilicum) exhibit greater tolerance to high B concentrations than do green-leafed cultivars. We hypothesised that foliar anthocyanins protect basil leaf mesophyll from photo-oxidative stress when chloroplast function is compromised by B toxicity. Purple-leafed 'Red Rubin' and green-leafed 'Tigullio' cultivars, grown with high or negligible edaphic B, were given a photoinhibitory light treatment. Possible effects of photoabatement by anthocyanins were simulated by superimposing a purple polycarbonate filter on the green leaves. An ameliorative effect of light filtering on photosynthetic quantum yield and on photo-oxidative load was observed in B-stressed plants. In addition, when green protoplasts from both cultivars were treated with B and illuminated through a screen of anthocyanic protoplasts or a polycarbonate film which approximated cyanidin-3-O-glucoside optical properties, the degree of photoinhibition, hydrogen peroxide production, and malondialdehyde content were reduced. The data provide evidence that anthocyanins exert a photoprotective role in purple-leafed basil mesophyll cells, thereby contributing to improved tolerance to high B concentrations.
Ormeci, Banu; Linden, Karl G
2008-11-01
Fluorescence in situ hybridization (FISH) provides a unique tool to study micro-organisms associated with particles and flocs. FISH enables visual examination of micro-organisms while they are structurally intact and associated with particles. However, application of FISH to wastewater and sludge samples presents a specific set of problems. Wastewater samples generate high background fluorescence due to their organic and inorganic content making it difficult to differentiate a probe-conferred signal from naturally fluorescing particles with reasonable certainty. Furthermore, some of the FISH steps involve harsh treatment of samples, and are likely to disrupt the floc structure. This study developed a FISH protocol for studying micro-organisms that are associated with particles and flocs. The results indicate that choice of a proper fluorochrome and labeling technique is a key step in reducing the background fluorescence and non-specific binding, and increasing the intensity of the probe signal. Compared to other fluorochromes tested, CY3 worked very well and enabled the observation of particles and debris in red and probe signal from microbes in yellow. Fixation, hybridization, and washing steps disturbed the floc structure and particle-microbe association. Modifications to these steps were necessary, and were achieved by replacing centrifugation with filtration and employment of nylon filters. Microscope slides generated excellent quality images, but polycarbonate membrane filters performed better in preserving the floc structure.
Optimizing Fungal DNA Extraction Methods from Aerosol Filters
NASA Astrophysics Data System (ADS)
Jimenez, G.; Mescioglu, E.; Paytan, A.
2016-12-01
Fungi and fungal spores can be picked up from terrestrial ecosystems, transported long distances, and deposited into marine ecosystems. It is important to study dust-borne fungal communities, because they can stay viable and effect the ambient microbial populations, which are key players in biogeochemical cycles. One of the challenges of studying dust-borne fungal populations is that aerosol samples contain low biomass, making extracting good quality DNA very difficult. The aim of this project was to increase DNA yield by optimizing DNA extraction methods. We tested aerosol samples collected from Haifa, Israel (polycarbonate filter), Monterey Bay, CA (quartz filter) and Bermuda (quartz filter). Using the Qiagen DNeasy Plant Kit, we tested the effect of altering bead beating times and incubation times, adding three freeze and thaw steps, initially washing the filters with buffers for various lengths of time before using the kit, and adding a step with 30 minutes of sonication in 65C water. Adding three freeze/thaw steps, adding a sonication step, washing with a phosphate buffered saline overnight, and increasing incubation time to two hours, in that order, resulted in the highest increase in DNA for samples from Israel (polycarbonate). DNA yield of samples from Monterey (quart filter) increased about 5 times when washing with buffers overnight (phosphate buffered saline and potassium phophate buffer), adding a sonication step, and adding three freeze and thaw steps. Samples collected in Bermuda (quartz filter) had the highest increase in DNA yield from increasing incubation to 2 hours, increasing bead beating time to 6 minutes, and washing with buffers overnight (phosphate buffered saline and potassium phophate buffer). Our results show that DNA yield can be increased by altering various steps of the Qiagen DNeasy Plant Kit protocol, but different types of filters collected at different sites respond differently to alterations. These results can be used as preliminary results to continue developing fungi DNA extraction methods. Developing these methods will be important as dust storms are predicted to increase due to increased draughts and anthropogenic activity, and the fungal communities of these dust-storms are currently relatively understudied.
Binding, uptake, and transport of hypericin by Caco-2 cell monolayers.
Sattler, S; Schaefer, U; Schneider, W; Hoelzl, J; Lehr, C M
1997-10-01
The biological evaluation of hypericin in various test models is hampered by its very poor water solubility. In the present study cyclodextrin formulations and liposomal preparations were investigated for improved delivery and solubility of hypericin in aqueous buffer systems. Caco-2 cells, grown to tight monolayers on 96-well tissue culture plates as well as on Transwell polycarbonate filters, were used to study the membrane binding and the epithelial transport of hypericin. Cumulative transport of hypericin, which could not be measured without the use of cyclodextrins, in apical-to-basolateral direction from cyclodextrin-hypericin buffer solutions was 3-5% at 37 degrees C and approximately 0.12% at 4 degrees C after 5 h. After an incubation time of 1 h at 37 and 4 degrees C, 12.7% +/- 2.6% and 6.5% +/- 0.8%, respectively, of hypericin were found to be bound to or taken up by Caco-2 cells. Liposomal formulations markedly increased the solubility of hypericin in Krebs-Ringer buffer, but there was no effect observed on the binding and transport of hypericin delivered by liposomes in the Caco-2 cell model. Due to the fluorescence properties of hypericin, its interaction with the cells could be visualized by confocal laser scanning microscopy. The results indicate that a significant accumulation of the drug in the cell membrane and the cell nucleus membrane takes place. We conclude that hypericin is absorbed through the intestinal epithelium by passive transcellular diffusion and that increasing its solubility by cyclodextrin appears as a promising approach to increase its oral bioavailability for pharmaceutical formulations.
Taheri, M; Jafarizadeh, M; Baradaran, S; Zainali, Gh
2006-12-01
Passive radon dosimeters, based on alpha particle etched track detectors, are widely used for the assessment of radon exposure. These methods are often applied in radon dosimetry for long periods of time. In this research work, we have developed a highly efficient method of personal/environmental radon dosimetry that is based upon the detection of alpha particles from radon daughters, (218)Po and (214)Po, using a polycarbonate detector (PC). The radon daughters are collected on the filter surface by passing a fixed flow of air through it and the PC detector, placed at a specified distance from the filter, is simultaneously exposed to alpha particles. After exposure, the latent tracks on the detector are made to appear by means of an electrochemical etching process; these are proportional to the radon dose. The air flow rate and the detector-filter distance are the major factors that can affect the performance of the dosimeter. The results obtained in our experimental investigations have shown that a distance of 1.5 cm between the detector and the filter, an absorber layer of Al with a thickness of 12 microm and an air flow rate of 4 l min(-1) offer the best design parameters for a high efficiency radon dosimeter. Then, the designed dosimeter was calibrated against different values of radon exposures and the obtained sensitivity was found to be 2.1 (tracks cm(-2)) (kBq h m(-3))(-1). The most important advantages of this method are that it is reliable, fast and convenient when used for radon dose assessment. In this paper, the optimized parameters of the dosimeter structure and its calibration procedure are presented and discussed.
Bechy-Loizeau, Anne-Laure; Flandrois, Jean-Pierre; Abaibou, Hafid
2015-07-01
On the ISS, as on Earth, water is an essential element for life and its quality control on a regular basis allows to ensure the health of the crew and the integrity of equipment. Currently, microbial water analysis onboard ISS still relies on the traditional culture-based microbiology methods. Molecular methods based on the amplification of nucleic acids for microbiological analysis of water quality show enormous potential and are considered as the best alternative to culture-based methods. For this reason, the Midass, a fully integrated and automated prototype was designed conjointly by ESA and bioMérieux for a rapid monitoring of the microbiological quality of air. The prototype allows air sampling, sample processing and the amplification/detection of nucleic acids. We describe herein the proof of principle of an analytical approach based on molecular biology that could fulfill the ESA's need for a rapid monitoring of the microbiological quality of recycled water onboard ISS. Both concentration and recovery of microorganisms are the main critical steps when the microfiltration technology is used for water analysis. Among filters recommended standards for monitoring the microbiological quality of the water, the polycarbonate filter was fully in line with the requirements of the ISO 7704-1985 standard in terms of efficacy of capture and recovery of bacteria. Moreover, this filter does not retain nucleic acids on the surface and has no inhibitory effect on their downstream processing steps such as purification and amplification/detection. Although the Midass system was designed for the treatment of air samples, the first results on the integration of PC filters were encouraging. Nevertheless, system modifications are needed to better adapt the Midass system for the monitoring of the microbiological water quality. Copyright © 2015 The Committee on Space Research (COSPAR). Published by Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Tompkins, Brendan D.
This dissertation examines methods for modifying the composition and behavior of polymer material surfaces. This is accomplished using (1) low-temperature low-density oxidizing plasmas to etch and implant new functionality on polymers, and (2) plasma enhanced chemical vapor deposition (PECVD) techniques to fabricate composite polymer materials. Emphases are placed on the structure of modified polymer surfaces, the evolution of polymer surfaces after treatment, and the species responsible for modifying polymers during plasma processing. H2O vapor plasma modification of high-density polyethylene (HDPE), low-density polyethylene (LDPE), polypropylene (PP), polystyrene (PS), polycarbonate (PC), and 75A polyurethane (PU) was examined to further our understanding of polymer surface reorganization leading to hydrophobic recovery. Water contact angles (wCA) measurements showed that PP and PS were the most susceptible to hydrophobic recovery, while PC and HDPE were the most stable. X-ray photoelectron spectroscopy (XPS) revealed a significant quantity of polar functional groups on the surface of all treated polymer samples. Shifts in the C1s binding energies (BE) with sample age were measured on PP and PS, revealing that surface reorganization was responsible for hydrophobic recovery on these materials. Differential scanning calorimetry (DSC) was used to rule out the intrinsic thermal properties as the cause of reorganization and hydrophobic recovery on HDPE, LDPE, and PP. The different contributions that polymer cross-linking and chain scission mechanisms make to polymer aging effects are considered. The H2O plasma treatment technique was extended to the modification of 0.2 microm and 3.0 microm track-etched polycarbonate (PC-TE) and track-etched polyethylene terephthalate (PET-TE) membranes with the goal of permanently increasing the hydrophilicity of the membrane surfaces. Contact angle measurements on freshly treated and aged samples confirmed the wettability of the membrane surfaces was significantly improved by plasma treatment. XPS and SEM analyses revealed increased oxygen incorporation onto the surface of the membranes, without any damage to the surface or pore structure. Contact angle measurements on a membrane treated in a stacked assembly suggest the plasma effectively modified the entire pore cross section. Plasma treatment also increased water flux through the membranes, with results from plasma modified membranes matching those from commercially available hydrophilic membranes (treated with wetting agent). Mechanisms for the observed modification are discussed in terms of OH and O radicals implanting oxygen functionality into the polymers. Oxidizing plasma systems (O2, CO2, H2O vapor, and formic acid vapor) were used to modify track-etched polycarbonate membranes and explore the mechanisms and species responsible for etching polycarbonate during plasma processing. Etch rates were measured using scanning electron microscopy; modified polycarbonate surfaces were further characterized using x-ray photoelectron spectroscopy and water contact angles. Etch rates and surface characterization results were combined with optical emission spectroscopy data used to identify gas-phase species and their relative densities. Although the oxide functionalities implanted by each plasma system were similar, the H2O vapor and formic acid vapor plasmas yielded the lowest contact angles after treatment. The CO2, H2O vapor, and formic acid vapor plasma-modified surfaces were, however, found to be similarly stable one month after treatment. Overall, etch rate correlated directly to the relative gas-phase density of atomic oxygen and, to a lesser extent, hydroxyl radicals. PECVD of acetic acid vapor (CH3COOH) was used to deposit films on PC-TE and silicon wafer substrates. The CH3COOH films were characterized using XPS, wCA, and SEM. This modification technique resulted in continuous deposition and self-limiting deposition of a-CxO yHz films on Si wafers and PC-TE, respectively. The self-limiting deposition on PC-TE revealed that resulting films have minimal impact on 3D PC structures. This technique would allow for more precise fabrication of patterned or nano-textured PC. PECVD is used to synthesize hydrocarbon/fluorocarbon thin films with compositional gradients by continuously changing the ratio of gases in a C 3F8/H2 plasma. The films are characterized using variable angle spectroscopic ellipsometry (VASE), Fourier transform infrared spectroscopy (FTIR), XPS, wCA, and SEM. These methods revealed that shifting spectroscopic signals can be used to characterize organization in the deposited film. Using these methods, along with gas-phase diagnostics, film chemistry and the underlying deposition mechanisms are elucidated, leading to a model that accurately predicts film thickness.
NASA Astrophysics Data System (ADS)
Marty, Adam J.
The purpose of this research is to demonstrate the ability to generate and characterize a nanometer sized aerosol using solutions, suspensions, and a bulk nanopowder, and to research the viability of using an acoustic dry aerosol generator/elutriator (ADAGE) to aerosolize a bulk nanopowder into a nanometer sized aerosol. The research compares the results from a portable scanning mobility particle sizer (SMPS) to the more traditional method of counting and sizing particles on a filter sample using scanning electron microscopy (SEM). Sodium chloride aerosol was used for the comparisons. The sputter coating thickness, a conductive coating necessary for SEM, was measured on different sizes of polystyrene latex spheres (PSLS). Aluminum oxide powder was aerosolized using an ADAGE and several different support membranes and sound frequency combinations were explored. A portable SMPS was used to determine the size distributions of the generated aerosols. Polycarbonate membrane (PCM) filter samples were collected for subsequent SEM analysis. The particle size distributions were determined from photographs of the membrane filters. SMPS data and membrane samples were collected simultaneously. The sputter coating thicknesses on four different sizes of PSLS, range 57 nanometers (nm) to 220 nm, were measured using transmission electron microscopy and the results from the SEM and SMPS were compared after accounting for the sputter coating thickness. Aluminum oxide nanopowder (20 nm) was aerosolized using a modified ADAGE technique. Four different support membranes and four different sound frequencies were tested with the ADAGE. The aerosol was collected onto PCM filters and the samples were examined using SEM. The results indicate that the SMPS and SEM distributions were log-normally distributed with a median diameter of approximately 42 nm and 55 nm, respectively, and geometric standard deviations (GSD) of approximately 1.6 and 1.7, respectively. The two methods yielded similar distributional trends with a difference in median diameters of approximately 11 -- 15 nm. The sputter coating thickness on the different sizes of PSLSs ranged from 15.4 -- 17.4 nm. The aerosols generated, using the modified ADAGE, were low in concentration. The particles remained as agglomerates and varied widely in size. An aluminum foil support membrane coupled with a high sound frequency generated the smallest agglomerates. A well characterized sodium chloride aerosol was generated and was reproducible. The distributions determined using SEM were slightly larger than those obtained from SMPS, however, the distributions had relatively the same shape as reflected in their GSDs. This suggests that a portable SMPS is a suitable method for characterizing a nanoaerosol. The sizing techniques could be compared after correcting for the effects of the sputter coating necessary for SEM examination. It was determined that the sputter coating thickness on nano-sized particles and particles up to approximately 220 nm can be expected to be the same and that the sputter coating can add considerably to the size of a nanoparticle. This has important implications for worker health where nanoaerosol exposure is a concern. The sputter coating must be considered when SEM is used to describe a nanoaerosol exposure. The performance of the modified ADAGE was less than expected. The low aerosol output from the ADAGE prevented a more detailed analysis and was limited to only a qualitative comparison. Some combinations of support membranes and sound frequencies performed better than others, particularly conductive support membranes and high sound frequencies. In conclusion, a portable SMPS yielded results similar to those obtained by SEM. The sputter coating was the same thickness on the PSLSs studied. The sputter coating thickness must be considered when characterizing nanoparticles using SEM. Finally, a conductive support membrane and higher frequencies appeared to generate the smallest agglomerates using the ADAGE technique.
Filtration recovery of extracellular DNA from environmental ...
qPCR methods are able to analyze DNA from microbes within hours of collecting water samples, providing the promptest notification and public awareness possible when unsafe pathogenic levels are reached. Health risk, however, may be overestimated by the presence of extracellular DNA (eDNA) that is co-recovered by the filtration procedure which is the most commonly used method to concentrate target microbes from environmental waters. Using C. parvum 18S rRNA gene fragment as a representative of eDNA, we examined the impact of filters (types and pore sizes) and physiochemical properties of surface water samples on the recovery of spiked DNA. Our results indicated that binding affinities of various filter membranes were quantifiably different for eDNA fragments with the polycarbonate (PC) binding the least and mixed cellulose acetate and cellulose nitrate (MCE) binding the most as evidenced by up to 16% recovery of the spiked plasmid DNA with a pore size of 0.2µm. Water quality parameters also had a distinct influence on the recovery of eDNA which was enhanced by the presence of high total suspended solid (TSS) concentrations and reduced pH. At pH 5.5, with 150mg/L of clay, DNA recovery was increased to as much as 18%. By shielding the negative charge, thus increasing the interaction of DNA and colloids, the increase of Na+ and Ca+2 concentrations resulted in more DNA binding and consequently more recovery from environmental water samples. Therefore, in addition
Selective Functionalization of Arbitrary Nanowires
2006-11-02
3-mercaptopropyl)- trimethoxysilane (MPTMS). The wires were grown electrochemically in anodic aluminum oxide ( AAO ) templates. Selective deposition...In the past, templates composed of polycarbonate track-etched membranes or anodic aluminum oxide materials have been used for the construction of...modifier MPTMS was used to function- alize the AAO template because it can form covalent bonds with silanes and metal oxide surfaces21 and because of
Filtration device for rapid separation of biological particles from complex matrices
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kim, Sangil; Naraghi-Arani, Pejman; Liou, Megan
2018-01-09
Methods and systems for filtering of biological particles are disclosed. Filtering membranes separate adjacent chambers. Through osmotic or electrokinetic processes, flow of particles is carried out through the filtering membranes. Cells, viruses and cell waste can be filtered depending on the size of the pores of the membrane. A polymer brush can be applied to a surface of the membrane to enhance filtering and prevent fouling.
Artificially modified magnetic anisotropy in interconnected nanowire networks.
Araujo, Elsie; Encinas, Armando; Velázquez-Galván, Yenni; Martínez-Huerta, Juan Manuel; Hamoir, Gaël; Ferain, Etienne; Piraux, Luc
2015-01-28
Interconnected or crossed magnetic nanowire networks have been fabricated by electrodeposition into a polycarbonate template with crossed cylindrical nanopores oriented ±30° with respect to the surface normal. Tailor-made nanoporous polymer membranes have been designed by performing a double energetic heavy ion irradiation with fixed incidence angles. The Ni and Ni/NiFe nanowire networks have been characterized by magnetometry as well as ferromagnetic resonance and compared with parallel nanowire arrays of the same diameter and density. The most interesting feature of these nanostructured materials is a significant reduction of the magnetic anisotropy when the external field is applied perpendicular and parallel to the plane of the sample. This effect is attributed to the relative orientation of the nanowire axes with the applied field. Moreover, the microwave transmission spectra of these nanowire networks display an asymmetric linewidth broadening, which may be interesting for the development of low-pass filters. Nanoporous templates made of well-defined nanochannel network constitute an interesting approach to fabricate materials with controlled anisotropy and microwave absorption properties that can be easily modified by adjusting the relative orientation of the nanochannels, pore sizes and material composition along the length of the nanowire.
Plyuta, Vladimir; Lipasova, Valentina; Popova, Alexandra; Koksharova, Olga; Kuznetsov, Alexander; Szegedi, Erno; Chernin, Leonid; Khmel, Inessa
2016-07-01
The ability to form biofilms plays an important role in bacteria-host interactions, including plant pathogenicity. In this work, we investigated the action of volatile organic compounds (VOCs) produced by rhizospheric strains of Pseudomonas chlororaphis 449, Pseudomonas fluorescens B-4117, Serratia plymuthica IC1270, as well as Serratia proteamaculans strain 94, isolated from spoiled meat, on biofilms formation by three strains of Agrobacterium tumefaciens which are causative agents of crown-gall disease in a wide range of plants. In dual culture assays, the pool of volatiles emitted by the tested Pseudomonas and Serratia strains suppressed the formation of biofilms of A. tumefaciens strains grown on polycarbonate membrane filters and killed Agrobacterium cells in mature biofilms. The individual VOCs produced by the tested Pseudomonas strains, that is, ketones (2-nonanone, 2-heptanone, 2-undecanone), and dimethyl disulfide (DMDS) produced by Serratia strains, were shown to kill A. tumefaciens cells in mature biofilms and suppress their formation. The data obtained in this study suggest an additional potential of some ketones and DMDS as protectors of plants against A. tumefaciens strains, whose virulence is associated with the formation of biofilms on the infected plants. © 2016 APMIS. Published by John Wiley & Sons Ltd.
Antolak, John A.
2013-01-01
A total skin electron (TSE) floor technique is presented for treating patients who are unable to safely stand for extended durations. A customized flattening filter is used to eliminate the need for field junctioning, improve field uniformity, and reduce setup time. The flattening filter is constructed from copper and polycarbonate, fits into the linac's accessory slot, and is optimized to extend the useful height and width of the beam such that no field junctions are needed during treatment. A TSE floor with flattening filter (TSE FF) treatment course consisted of six patient positions: three supine and three prone. For all treatment fields, electron beam energy was 6 MeV; collimator settings were an x of 30 cm, y of 40 cm, and θcoll of 0°; and a 0.4 cm thick polycarbonate spoiler was positioned in front of the patient. Percent depth dose (PDD) and photon contamination for the TSE FF technique were compared with our standard technique, which is similar to the Stanford technique. Beam profiles were measured using radiochromic film, and dose uniformity was verified using an anthropomorphic radiological phantom. The TSE FF technique met field uniformity requirements specified by the American Association of Physicists in Medicine Task Group 30. TSE FF R80 ranges from 4 to 4.8 mm. TSE FF photon contamination was ~ 3%. Anthropomorphic radiological phantom verification demonstrated that dose to the entire skin surface was expected to be within about ±15% of the prescription dose, except for the perineum, scalp vertex, top of shoulder, and soles of the feet. The TSE floor technique presented herein eliminates field junctioning, is suitable for patients who cannot safely stand during treatment, and provides comparable quality and uniformity to the Stanford technique. PACS number: 87 PMID:24036864
Morphology of Nano and Micro Fiber Structures in Ultrafine Particles Filtration
NASA Astrophysics Data System (ADS)
Kimmer, Dusan; Vincent, Ivo; Fenyk, Jan; Petras, David; Zatloukal, Martin; Sambaer, Wannes; Zdimal, Vladimir
2011-07-01
Selected procedures permitting to prepare homogeneous nanofibre structures of the desired morphology by employing a suitable combination of variables during the electrospinning process are presented. A comparison (at the same pressure drop) was made of filtration capabilities of planar polyurethane nanostructures formed exclusively by nanofibres, space polycarbonate nanostructures having bead spacers, structures formed by a combination of polymethyl methacrylate micro- and nanofibres and polypropylene meltblown microstructures, through which ultrafine particles of ammonium sulphate 20-400 nm in size were filtered. The structures studied were described using a new digital image analysis technique based on black and white images obtained by scanning electron microscopy. More voluminous structures modified with distance microspheres and having a greater thickness and mass per square area of the material, i.e. structures possessing better mechanical properties, demanded so much in nanostructures, enable preparation of filters having approximately the same free volume fraction as flat nanofibre filters but an increased effective fibre surface area, changed pore size morphology and, consequently, a higher filter quality.
Microfabrication of three-dimensional filters for liposome extrusion
NASA Astrophysics Data System (ADS)
Baldacchini, Tommaso; Nuñez, Vicente; LaFratta, Christopher N.; Grech, Joseph S.; Vullev, Valentine I.; Zadoyan, Ruben
2015-03-01
Liposomes play a relevant role in the biomedical field of drug delivery. The ability of these lipid vesicles to encapsulate and transport a variety of bioactive molecules has fostered their use in several therapeutic applications, from cancer treatments to the administration of drugs with antiviral activities. Size and uniformity are key parameters to take into consideration when preparing liposomes; these factors greatly influence their effectiveness in both in vitro and in vivo experiments. A popular technique employed to achieve the optimal liposome dimension (around 100 nm in diameter) and uniform size distribution is repetitive extrusion through a polycarbonate filter. We investigated two femtosecond laser direct writing techniques for the fabrication of three-dimensional filters within a microfluidics chip for liposomes extrusion. The miniaturization of the extrusion process in a microfluidic system is the first step toward a complete solution for lab-on-a-chip preparation of liposomes from vesicles self-assembly to optical characterization.
Taheri, M; Sohrabi, M; Jaleh, B; Hosseini, T; Montazer Rahmati, M M
2009-12-01
In the present paper a method has been developed for the determination of (226)Ra in water by the detection, using a solid-state nuclear track detector (SSNTD), of alpha particles from (226)Ra in equilibrium with (222)Rn in micro-precipitates collected on a filter. The micro-precipitates were prepared from environmental water samples by collection of radium with lead as Pb/RaSO(4). Several factors affect the (226)Ra precipitation on the filter and its recovery, in particular the filter pore size. Therefore in this experiment Whatman #42 and Millipore filters with different pore sizes were used. Using a 0.45 microm Millipore filter, the recovery efficiency was increased up to 96%, and the alpha self-absorption and scattering decreased remarkably. For efficient detection of alphas from (226)Ra/(222)Rn in equilibrium, three types of SSNTD were used-polycarbonate (PC) electrochemically etched (ECE), CR-39 and LR-115 chemically etched (CE). By preparing a standard micro-precipitate on a filter with known (226)Ra/(222)Rn characteristics, the calibration response of each detector and its minimum detection limit (MDL) were determined.
NASA Technical Reports Server (NTRS)
Wozniakiewicz, P. J.; Bradley, J. P.; Price, M. C.; Zolensky, M. E.; Ishii, H. A.; Brownlee, D. E.; Russell, S. S.
2014-01-01
Examination of impact craters on the Long Duration Exposure Facility satellite indicate a present day micrometeoroid flux of approx. 30,000 tonnes [1 after 2]. But what portion of this material arrives at the Earth's surface as micrometeorites? Studies of available micrometeorite collections from deep sea sediments [e.g. 3], Greenland blue ice [e.g. 4] and the South Pole water well [e.g. 1] may be complicated by terrestrial weathering and, in some cases, collection bias (magnetic separation for deep sea sediments) and poorly constrained ages. We have recently set up a micrometeorite collection station on Kwajalein Island in the Republic of the Marshall Islands in the Pacific Ocean, using high volume air samplers to collect particles directly from the atmosphere. By collecting in this way, the terrestrial age of the particles is known, the weathering they experience is minimal, and we are able to constrain particle arrival times. Collecting at this location also exploits the considerably reduced anthropogenic background [5]. Method: High volume air samplers were installed on top of the two-story airport building on Kwajalein. These were fitted with polycarbonate membrane filters with 5µm diameter perforations. The flow rates were set to 0.5m3/min, and filters were changed once a week. After collection, filters were washed to remove salt and concentrate particles [see 5] in preparation for analysis by SEM. Results and Discussion: A selection of filters have been prepared and surveyed. Due to their ease of identification our initial investigations have focused on particles resembling cosmic spherules. The spheres can be divided into three main groups: 1. Silicate spherules rich in Al, Ca, K and Na (to varying degrees), 2. Silicate spherules rich in Mg and Fe and 3. Fe-rich spherules. Group 1 spherules are often vesiculated and can occur as aggregates. They are similar in appearance and composition to volcanic microspheres [e.g. 6] and are thus likely terrestrial in origin (volcanic). Those of groups 2 and 3, however, typically exhibit quenched surface textures consistent with cosmic spherules. Initial results suggest there is significant variation in the abundance of these groups from filter to filter. Work is ongoing to fully characterize these spherules and to constrain their flux with time.
Hosoglu, Fatih; Fitch, Mark W
2012-01-01
In this study, a single silicone rubber membrane biofilter was compared to a lava rock biotrickling filter to examine the aerobic biofiltration of synthetic landfill gas including odorous limonene. The membrane bioreactor and biotrickling filter showed, respectively, maximum elimination capacities of 17 g m(-3) h(-1) and 31.3 g m(-3) h(-1) for limonene and removal efficiencies of 11 % and 18 % for methane. The membrane bioreactor was apparently mass transfer-limited and the biotrickling filter was reaction-limited.
Extremely high efficient nanoreactor with Au@ZnO catalyst for photocatalysis
NASA Astrophysics Data System (ADS)
Su, Chung-Yi; Yang, Tung-Han; Gurylev, Vitaly; Huang, Sheng-Hsin; Wu, Jenn-Ming; Perng, Tsong-Pyng
2015-10-01
We fabricated a photocatalytic Au@ZnO@PC (polycarbonate) nanoreactor composed of monolayered Au nanoparticles chemisorbed on conformal ZnO nanochannel arrays within the PC membrane. A commercial PC membrane was used as the template for deposition of a ZnO shell into the pores by atomic layer deposition (ALD). Thioctic acid (TA) with sufficient steric stabilization was used as a molecular linker for functionalization of Au nanoparticles in a diameter of 10 nm. High coverage of Au nanoparticles anchored on the inner wall of ZnO nanochannels greatly improved the photocatalytic activity for degradation of Rhodamine B. The membrane nanoreactor achieved 63% degradation of Rhodamine B within only 26.88 ms of effective reaction time owing to its superior mass transfer efficiency based on Damköhler number analysis. Mass transfer limitation can be eliminated in the present study due to extremely large surface-to-volume ratio of the membrane nanoreactor.
Gao, Siyue; Glasser, Jessica; He, Lili
2016-02-19
We demonstrate a method to fabricate highly sensitive surface-enhanced Raman spectroscopic (SERS) substrates using a filter syringe system that can be applied to the detection of various chemical contaminants. Silver nanoparticles (Ag NPs) are synthesized via reduction of silver nitrate by sodium citrate. Then the NPs are aggregated by sodium chloride to form nanoclusters that could be trapped in the pores of the filter membrane. A syringe is connected to the filter holder, with a filter membrane inside. By loading the nanoclusters into the syringe and passing through the membrane, the liquid goes through the membrane but not the nanoclusters, forming a SERS-active membrane. When testing the analyte, the liquid sample is loaded into the syringe and flowed through the Ag NPs coated membrane. The analyte binds and concentrates on the Ag NPs coated membrane. Then the membrane is detached from the filter holder, air dried and measured by a Raman instrument. Here we present the study of the volume effect of Ag NPs and sample on the detection sensitivity as well as the detection of 10 ppb ferbam and 1 ppm ampicillin using the developed assay.
NASA Astrophysics Data System (ADS)
Ahmad, Farhan; Mish, Barbara; Qiu, Jian; Singh, Amarnauth; Varanasi, Rao; Bedford, Eilidh; Smith, Martin
2016-03-01
Contamination tolerances in semiconductor manufacturing processes have changed dramatically in the past two decades, reaching below 20 nm according to the guidelines of the International Technology Roadmap for Semiconductors. The move to narrower line widths drives the need for innovative filtration technologies that can achieve higher particle/contaminant removal performance resulting in cleaner process fluids. Nanoporous filter membrane metrology tools that have been the workhorse over the past decade are also now reaching limits. For example, nanoparticle (NP) challenge testing is commonly applied for assessing particle retention performance of filter membranes. Factors such as high NP size dispersity, low NP detection sensitivity, and high NP particle-filter affinity impose challenges in characterizing the next generation of nanoporous filter membranes. We report a novel bio-surrogate, 5 nm DNA-dendrimer conjugate for evaluating particle retention performance of nanoporous filter membranes. A technique capable of single molecule detection is employed to detect sparse concentration of conjugate in filter permeate, providing >1000- fold higher detection sensitivity than any existing 5 nm-sized particle enumeration technique. This bio-surrogate also offers narrow size distribution, high stability and chemical tunability. This bio-surrogate can discriminate various sub-15 nm pore-rated nanoporous filter membranes based on their particle retention performance. Due to high bio-surrogate detection sensitivity, a lower challenge concentration of bio-surrogate (as compared to other NPs of this size) can be used for filter testing, providing a better representation of customer applications. This new method should provide better understanding of the next generation filter membranes for removing defect-causing contaminants from lithography processes.
Filter Membrane Effects on Water-Extractable Phosphorus Concentrations from Soil.
Norby, Jessica; Strawn, Daniel; Brooks, Erin
2018-03-01
To accurately assess P concentrations in soil extracts, standard laboratory practices for monitoring P concentrations are needed. Water-extractable P is a common analytical test to determine P availability for leaching from soils, and it is used to determine best management practices. Most P analytical tests require filtration through a filter membrane with 0.45-μm pore size to distinguish between particulate and dissolved P species. However, filter membrane type is rarely specified in method protocols, and many different types of membranes are available. In this study, three common filter membrane materials (polyether sulfone, nylon, and nitrocellulose), all with 0.45-μm pore sizes, were tested for analytical differences in total P concentrations and dissolved reactive P (DRP) concentrations in water extracts from six soils sampled from two regions. Three of the extracts from the six soil samples had different total P concentrations for all three membrane types. The other three soil extracts had significantly different total P results from at least one filter membrane type. Total P concentration differences were as great as 35%. The DRP concentrations in the extracts were dependent on filter type in five of the six soil types. Results from this research show that filter membrane type is an important parameter that affects concentrations of total P and DRP from soil extracts. Thus, membrane type should be specified in soil extraction protocols. Copyright © by the American Society of Agronomy, Crop Science Society of America, and Soil Science Society of America, Inc.
Assessment of a membrane drinking water filter in an emergency setting.
Ensink, Jeroen H J; Bastable, Andy; Cairncross, Sandy
2015-06-01
The performance and acceptability of the Nerox(TM) membrane drinking water filter were evaluated among an internally displaced population in Pakistan. The membrane filter and a control ceramic candle filter were distributed to over 3,000 households. Following a 6-month period, 230 households were visited and filter performance and use were assessed. Only 6% of the visited households still had a functioning filter, and the removal performance ranged from 80 to 93%. High turbidity in source water (irrigation canals), together with high temperatures and large family size were likely to have contributed to poor performance and uptake of the filters.
NASA Technical Reports Server (NTRS)
Laicer, Castro; Rasimick, Brian; Green, Zachary
2012-01-01
Cabin environmental control is an important issue for a successful Moon mission. Due to the unique environment of the Moon, lunar dust control is one of the main problems that significantly diminishes the air quality inside spacecraft cabins. Therefore, this innovation was motivated by NASA s need to minimize the negative health impact that air-suspended lunar dust particles have on astronauts in spacecraft cabins. It is based on fabrication of a hybrid filter comprising nanofiber nonwoven layers coated on porous polymer membranes with uniform cylindrical pores. This design results in a high-efficiency gas particulate filter with low pressure drop and the ability to be easily regenerated to restore filtration performance. A hybrid filter was developed consisting of a porous membrane with uniform, micron-sized, cylindrical pore channels coated with a thin nanofiber layer. Compared to conventional filter media such as a high-efficiency particulate air (HEPA) filter, this filter is designed to provide high particle efficiency, low pressure drop, and the ability to be regenerated. These membranes have well-defined micron-sized pores and can be used independently as air filters with discreet particle size cut-off, or coated with nanofiber layers for filtration of ultrafine nanoscale particles. The filter consists of a thin design intended to facilitate filter regeneration by localized air pulsing. The two main features of this invention are the concept of combining a micro-engineered straight-pore membrane with nanofibers. The micro-engineered straight pore membrane can be prepared with extremely high precision. Because the resulting membrane pores are straight and not tortuous like those found in conventional filters, the pressure drop across the filter is significantly reduced. The nanofiber layer is applied as a very thin coating to enhance filtration efficiency for fine nanoscale particles. Additionally, the thin nanofiber coating is designed to promote capture of dust particles on the filter surface and to facilitate dust removal with pulse or back airflow.
Hamamoto, Ryo; Ito, Hidemi; Hirohara, Makoto; Chang, Ryongsok; Hongo-Hirasaki, Tomoko; Hayashi, Tomohiro
2018-03-01
Membrane fouling commonly occurs in all filter types during virus filtration in protein-based biopharmaceutical manufacturing. Mechanisms of decline in virus filter performance due to membrane fouling were investigated using a cellulose-based virus filter as a model membrane. Filter performance was critically dependent on solution conditions; specifically, ionic strength. To understand the interaction between immunoglobulin G (IgG) and cellulose, sensors coated with cellulose were fabricated for surface plasmon resonance and quartz crystal microbalance with energy dissipation measurements. The primary cause of flux decline appeared to be irreversible IgG adsorption on the surface of the virus filter membrane. In particular, post-adsorption conformational changes in the IgG molecules promoted further irreversible IgG adsorption, a finding that could not be adequately explained by DLVO theory. Analyses of adsorption and desorption and conformational changes in IgG molecules on cellulose surfaces mimicking cellulose-based virus removal membranes provide an effective approach for identifying ways of optimizing solution conditions to maximize virus filter performance. © 2017 American Institute of Chemical Engineers Biotechnol. Prog., 34:379-386, 2018. © 2017 American Institute of Chemical Engineers.
Modeling filtration and fouling with a microstructured membrane filter
NASA Astrophysics Data System (ADS)
Cummings, Linda; Sanaei, Pejman
2017-11-01
Membrane filters find widespread use in diverse applications such as A/C systems and water purification. While the details of the filtration process may vary significantly, the broad challenge of efficient filtration is the same: to achieve finely-controlled separation at low power consumption. The obvious resolution to the challenge would appear simple: use the largest pore size consistent with the separation requirement. However, the membrane characteristics (and hence the filter performance) are far from constant over its lifetime: the particles removed from the feed are deposited within and on the membrane filter, fouling it and degrading the performance over time. The processes by which this occurs are complex, and depend on several factors, including: the internal structure of the membrane and the type of particles in the feed. We present a model for fouling of a simple microstructured membrane, and investigate how the details of the microstructure affect the filtration efficiency. Our idealized membrane consists of bifurcating pores, arranged in a layered structure, so that the number (and size) of pores changes in the depth of the membrane. In particular, we address how the details of the membrane microstructure affect the filter lifetime, and the total throughput. NSF DMS 1615719.
Schaeffer, A J; Jones, J M; Duncan, J L; Chmiel, J S; Plotkin, B J; Falkowski, W S
1982-01-01
Adherence of Escherichia coli to human uroepithelial cells obtained from the midstream urine of healthy women, nd to vaginal and buccal cells obtained from 11 healthy women and 24 patients who had had at least three urinary tract infections in the preceding year was studied. Bacteria labeled with [3H] uridine were used, and unattached organisms were separated from the epithelial cells by vacuum filtration through a polycarbonate membrane filter (5-micrometers-pore-size). A day-to-day variation in the receptivity of uroepithelial cells was noted. The range and rapidity of change in adherence to both vaginal and buccal cells were greater in patients than in controls. Adherence to vaginal cells was greater in patients than in controls (10.1 +/- 0.92 vs. 3.8 +/- 0.47 bacteria per cell [mean +/- S. E.], P less than 0.001), as was adherence to buccal cells (1.7 +/- 1.29 vs. 7.1 +/- 0.49, P = 0.002). There was a very strong, positive non-linear correlation between vaginal and buccal cell receptivity (R = 0.87, P less than 0.0001). The data suggest that susceptibility in women to urinary-tract infections is associated with widespread, fluctuating changes in the adhesive characteristics of epithelial cells.
Influence of Coliform Source on Evaluation of Membrane Filters
Brodsky, M. H.; Schiemann, D. A.
1975-01-01
Four brands of membrane filters were examined for total and fecal coliform recovery performance by two experimental approaches. Using diluted EC broth cultures of water samples, Johns-Manville filters were superior to Sartorius filters for fecal coliform but equivalent for total coliform recovery. Using river water samples, Johns-Manville filters were superior to Sartorius filters for total coliform but equivalent for fecal coliform recovery. No differences were observed between Johns-Manville and Millipore or Millipore and Sartorius filters for total or fecal coliform recoveries using either approach, nor was any difference observed between Millipore and Gelman filters for fecal coliform recovery from river water samples. These results indicate that the source of the coliform bacteria has an important influence on the conclusions of membrane filter evaluation studies. PMID:1106318
NASA Astrophysics Data System (ADS)
Lue, Shingjiang Jessie; Lo, Pei Wen; Hung, Ling-Yung; Tung, Yung Liang
This research investigates the cell performance and long-term stability of dye-sensitized solar cells (DSSCs) containing micro-porous polycarbonate (PC) film as the frame work material to stabilize the electrolyte solution. The track-etched PC film has cylindrical pore geometry, which is beneficial for ion transport in the electrolyte trapped inside the PC film. The photovoltaic efficiency of the DSSC with 0.2-μm PC membrane is 5.75 ± 0.73% under irradiation of 100 mW cm -2, which is slightly lower than that (6.34 ± 0.44%) of cells without PC film. The differences in fill factor and open-circuit voltage between the DSSCs with and without PC film are not statistically significant. The long-term cell performance is carried out at continuous illumination of 100 mW cm -2 (1 sun) and in darkness at 60 °C for up to 1000 h. There is no significant efficiency difference between the cells with and without PC film in light soaking (4.33% vs. 4.52%) for 960 h. In darkness, however, the cells with PC film demonstrate much higher efficiency (at 2.37%) than cells without PC (0.85%) after 1000 h. The improved long-term efficiency data and the higher percentage of working cells confirm the superior lifetime and performance using the micro-porous PC film.
Automated food microbiology: potential for the hydrophobic grid-membrane filter.
Sharpe, A N; Diotte, M P; Dudas, I; Michaud, G L
1978-01-01
Bacterial counts obtained on hydrophobic grid-membrane filters were comparable to conventional plate counts for Pseudomonas aeruginosa, Escherichia coli, and Staphylococcus aureus in homogenates from a range of foods. The wide numerical operating range of the hydrophobic grid-membrane filters allowed sequential diluting to be reduced or even eliminated, making them attractive as components in automated systems of analysis. Food debris could be rinsed completely from the unincubated hydrophobic grid-membrane filter surface without affecting the subsequent count, thus eliminating the possibility of counting food particles, a common source of error in electronic counting systems. PMID:100054
Li, Zhenguang; Hu, Wenhong; Zhao, Yunhui; Ren, Lixia; Yuan, Xiaoyan
2018-04-27
Integrated antibacterial and antifouling surfaces in favor of avoiding implant-related infections are necessarily required for biomaterials when they contact with the body fluid. In this work, an antibacterial and antifouling membrane was developed via cross-linking chitosan-g-eugenol and the zwitterionic copolymer poly(sulfobetaine methylacrylate-co-2-aminoethyl methacrylate) on the electrospun polycarbonate urethane substrate using genipin as a cross-linker. Antibacterial assays demonstrated that the prepared membranes had efficient antibacterial activity with 92.8 ± 2.5% and 95.2 ± 1.3% growth inhibition rates against Escherichia coli and Staphylococcus aureus, respectively. The investigations on antifouling activity and hemocompatibility of the membranes showed significant resistances to bacterial attachment, non-specific protein adsorption and platelet adhesion, and presented lower hemolytic activity and good anticoagulant activity as well. Moreover, cell culture assays indicated that the prepared membranes exerted no obvious cytotoxicity with more than 80% of relative L929 fibroblast viability. Therefore, the membranes with integrated antibacterial and antifouling properties could be potentially applied in promising indwelling devices. Copyright © 2018 Elsevier B.V. All rights reserved.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-01-05
... City, ND for the Zenon ZeeWeed 1000 membrane filter manufactured by General Electric Water & Process... membrane filters are manufactured in Canada, and meet Valley City's performance specifications and... the purchase of the Zenon ZeeWeed 1000 membrane filter for the Surface Water Treatment Plant upgrades...
Transfer in SDS of biotinylated proteins from acrylamide gels to an avidin-coated membrane filter.
Karlin, Arthur; Wang, Chaojian; Li, Jing; Xu, Qiang
2004-06-01
Avidin was covalently linked to aldehyde-derivatized polyethersulfone membrane filters. These filters were used in Western blot analysis of proteins reacted with biotinylation reagents and electrophoresed in sodium dodecyl sulfate (SDS) on polyacrylamide gels. Electrophoretic transfer from the gels to these filters was in 0.1% SDS, in which the covalently bound avidin retained its biotin-binding capacity. We compared Western blots on avidin-coated membrane filters of biotinylated and nonbiotinylated forms of mouse immunoglobulin G (IgG), mouse IgG heavy chain, muscle-type acetylcholine receptor alpha subunit, and fused alpha and beta subunits of receptor. Biotinylated proteins were captured with high specificity compared to their nonbiotinylated counterparts and sensitively detected on the avidin-coated membranes.
Internal Structure and Morphology Profile in Optimizing Filter Membrane Performance
NASA Astrophysics Data System (ADS)
Sanaei, Pejman; Cummings, Linda J.
Membrane filters are in widespread use, and manufacturers have considerable interest in improving their performance, in terms of particle retention properties, and total throughput over the filter lifetime. A good question to ask is therefore: what is the optimal configuration of filter membranes, in terms of internal morphology (pore size and shape), to achieve the most efficient filtration? To answer this question, we must first propose a robust measure of filtration performance. As filtration occurs the membrane becomes blocked, or fouled, by the impurities in the feed solution, and any performance measure must take account of this. For example, one performance measure might be the total throughput (the volume of filtered feed solution) at the end of the filtration process, when the membrane is so badly blocked that it is deemed no longer functional. Here we present a simplified mathematical model, which (i) characterizes membrane internal pore structure via pore or permeability profiles in the depth of the membrane; (ii) accounts for various membrane fouling mechanisms (adsorption, blocking and cake formation); and (iv) predicts the optimum pore profile for our chosen performance measure. NSF DMS-1261596 and NSF DMS-1615719.
Pneumatic System for Concentration of Micrometer-Size Lunar Soil
NASA Technical Reports Server (NTRS)
McKay, David; Cooper, Bonnie
2012-01-01
A report describes a size-sorting method to separate and concentrate micrometer- size dust from a broad size range of particles without using sieves, fluids, or other processes that may modify the composition or the surface properties of the dust. The system consists of four processing units connected in series by tubing. Samples of dry particulates such as lunar soil are introduced into the first unit, a fluidized bed. The flow of introduced nitrogen fluidizes the particulates and preferentially moves the finer grain sizes on to the next unit, a flat plate impactor, followed by a cyclone separator, followed by a Nuclepore polycarbonate filter to collect the dust. By varying the gas flow rate and the sizes of various orifices in the system, the size of the final and intermediate particles can be varied to provide the desired products. The dust can be collected from the filter. In addition, electron microscope grids can be placed on the Nuclepore filter for direct sampling followed by electron microscope characterization of the dust without further handling.
New combat laser and ballistic eye protection goggles
NASA Astrophysics Data System (ADS)
Belkin, Michael
1996-04-01
Up to 10% of all combat casualties involve eye injuries which are becoming more severe, bilateral and likely to lead to a retained intraocular foreign body. The modern battlefield is permeated with laser radiation from range finders, target designators and perhaps laser weapons aimed at producing visual incapacitation. In future wars, therefore, the likelihood of eye injuries is very high. We sought to devise means to protect the eye from military relevant injurious agents. Almost all ballistic injuries can be prevented by using polycarbonate goggles. They must not, however, interfere with the soldier's functions such as the use of binoculars or limit his visual fields. These problems are not insurmountable and we shall demonstrate new goggles design which we believe will be acceptable to the troops. The solution to laser protection is more difficult. For that purpose the goggles include outserts filters for various groups of laser wavelengths. The soldier will use the appropriate filter according to a reading from a laser detector which will indicate which filter is protective against the wavelength detected.
NASA Astrophysics Data System (ADS)
Singh, Krishna Pal; Dhek, Neeraj Singh; Nehra, Anuj; Ahlawat, Sweeti; Puri, Anu
2017-01-01
Nano-biosensors are excellent monitoring tools for rapid, specific, sensitive, inexpensive, in-field, on-line, and/or real-time detection of pathogens in foods, soil, air, and water samples. A variety of nano-materials (metallic, polymeric, and/or carbon-based) were employed to enhance the efficacy, efficiency, and sensitivity of these nano-biosensors, including graphene-based materials, especially graphene oxide (GO)-based materials. GO bears many oxygen-bearing groups, enabling ligand conjugation at the high density critical for sensitive detection. We have fabricated GO-modified nano-porous polycarbonate track-etched (PCTE) membranes that were conjugated to an Escherichia coli-specific antibody (Ab) and used to detect E. coli. The random distribution of nanopores on the PCTE membrane surface and the bright coating of the GO onto the membrane were confirmed by scanning electron microscope. Anti-E. coli β-gal Abs were conjugated to the GO surface via 1-ethyl-3,3-dimethylaminopropyl carbodiimide hydrochloride-N-hydroxysuccinimide chemistry; antibody coating was confirmed by the presence of a characteristic IR peak near 1600 cm- 1. A non-corresponding Ab (anti-Pseudomonas) was used as a negative control under identical conditions. When E. coli interacted anti-E.coli β-gal with Ab-coated GO-nano-biosensor units, we observed a clear shift in the IR peak from 3373.14 to 3315 cm- 1; in contrast, we did not observe any shift in IR peaks when the GO unit was coated with the non-corresponding Ab (anti-Pseudomonas). Therefore, the detection of E. coli using the described GO-nano-sensor unit is highly specific, is highly selective and can be applied for real-time monitoring of E. coli with a detection limit between 100 μg/mL and 10 μg/mL, similar to existing detection systems.
Singh, Krishna Pal; Dhek, Neeraj Singh; Nehra, Anuj; Ahlawat, Sweeti; Puri, Anu
2017-01-05
Nano-biosensors are excellent monitoring tools for rapid, specific, sensitive, inexpensive, in-field, on-line, and/or real-time detection of pathogens in foods, soil, air, and water samples. A variety of nano-materials (metallic, polymeric, and/or carbon-based) were employed to enhance the efficacy, efficiency, and sensitivity of these nano-biosensors, including graphene-based materials, especially graphene oxide (GO)-based materials. GO bears many oxygen-bearing groups, enabling ligand conjugation at the high density critical for sensitive detection. We have fabricated GO-modified nano-porous polycarbonate track-etched (PCTE) membranes that were conjugated to an Escherichia coli-specific antibody (Ab) and used to detect E. coli. The random distribution of nanopores on the PCTE membrane surface and the bright coating of the GO onto the membrane were confirmed by scanning electron microscope. Anti-E. coli β-gal Abs were conjugated to the GO surface via 1-ethyl-3,3-dimethylaminopropyl carbodiimide hydrochloride-N-hydroxysuccinimide chemistry; antibody coating was confirmed by the presence of a characteristic IR peak near 1600cm(-1). A non-corresponding Ab (anti-Pseudomonas) was used as a negative control under identical conditions. When E. coli interacted anti-E.coli β-gal with Ab-coated GO-nano-biosensor units, we observed a clear shift in the IR peak from 3373.14 to 3315cm(-1); in contrast, we did not observe any shift in IR peaks when the GO unit was coated with the non-corresponding Ab (anti-Pseudomonas). Therefore, the detection of E. coli using the described GO-nano-sensor unit is highly specific, is highly selective and can be applied for real-time monitoring of E. coli with a detection limit between 100μg/mL and 10μg/mL, similar to existing detection systems. Copyright © 2016 Elsevier B.V. All rights reserved.
Fabrication and Characterization of Surrogate Fuel Particles Using the Spark Erosion Method
NASA Astrophysics Data System (ADS)
Metzger, Kathryn E.
In light of the disaster at the Fukushima Daiichi Nuclear Plant, the Department of Energy's Advanced Fuels Program has shifted its interest from enhanced performance fuels to enhanced accident tolerance fuels. Dispersion fuels possess higher thermal conductivities than traditional light water reactor fuel and as a result, offer improved safety margins. The benefits of a dispersion fuel are due to the presence of the secondary non-fissile phase (matrix), which serves as a barrier to fission products and improves the overall thermal performance of the fuel. However, the presence of a matrix material reduces the fuel volume, which lowers the fissile content of dispersion. This issue can be remedied through the development of higher density fuel phases or through an optimization of fuel particle size and volume loading. The latter requirement necessitates the development of fabrication methods to produce small, micron-order fuel particles. This research examines the capabilities of the spark erosion process to fabricate particles on the order of 10 μm. A custom-built spark erosion device by CT Electromechanica was used to produce stainless steel surrogate fuel particles in a deionized water dielectric. Three arc intensities were evaluated to determine the effect on particle size. Particles were filtered from the dielectric using a polycarbonate membrane filter and vacuum filtration system. Fabricated particles were characterized via field emission scanning electron microscopy (FESEM), laser light particle size analysis, energy-dispersive spectroscopy (EDS), X-ray diffraction analysis (XRD), and gas pycnometry. FESEM images reveal that the spark erosion process produces highly spherical particles on the order of 10 microns. These findings are substantiated by the results of particle size analysis. Additionally, EDS and XRD results indicate the presence of oxide phases, which suggests the dielectric reacted with the molten debris during particle formation.
LeBouf, Ryan F; Miller, Arthur L; Stipe, Christopher; Brown, Jonathan; Murphy, Nate; Stefaniak, Aleksandr B
2013-06-01
Laboratory measurements of ultrafine titanium dioxide (TiO2) particulate matter loaded on filters were made using three field portable methods (X-ray fluorescence (XRF), laser-induced breakdown spectroscopy (LIBS), and Fourier-transform infrared (FTIR) spectroscopy) to assess their potential for determining end-of-shift exposure. Ultrafine TiO2 particles were aerosolized and collected onto 37 mm polycarbonate track-etched (PCTE) filters in the range of 3 to 578 μg titanium (Ti). Limit of detection (LOD), limit of quantification (LOQ), and calibration fit were determined for each measurement method. The LOD's were 11.8, 0.032, and 108 μg Ti per filter, for XRF, LIBS, and FTIR, respectively and the LOQ's were 39.2, 0.11, and 361 μg Ti per filter, respectively. The XRF calibration curve was linear over the widest dynamic range, up to the maximum loading tested (578 μg Ti per filter). LIBS was more sensitive but, due to the sample preparation method, the highest loaded filter measurable was 252 μg Ti per filter. XRF and LIBS had good predictability measured by regressing the predicted mass to the gravimetric mass on the filter. XRF and LIBS produced overestimations of 4% and 2%, respectively, with coefficients of determination (R(2)) of 0.995 and 0.998. FTIR measurements were less dependable due to interference from the PCTE filter media and overestimated mass by 2% with an R(2) of 0.831.
NASA Astrophysics Data System (ADS)
Chung, T. W.; Chen, C. K.; Hsu, S. H.
2017-11-01
Protein concentration process using filter membrane has a significant advantage on energy saving compared to the traditional drying processes. However, fouling on large membrane area and frequent membrane cleaning will increase the energy consumption and operation cost for the protein concentration process with filter membrane. In this study, the membrane filtration for protein concentration will be conducted and compared with the recent protein concentration technology. The analysis of operating factors for protein concentration process using filter membrane was discussed. The separation mechanism of membrane filtration was developed according to the size difference between the pore of membrane and the particle of filter material. The Darcy’s Law was applied to discuss the interaction on flux, TMP (transmembrane pressure) and resistance in this study. The effect of membrane pore size, pH value and TMP on the steady-state flux (Jst) and protein rejection (R) were studied. It is observed that the Jst increases with decreasing membrane pore size, the Jst increases with increasing TMP, and R increased with decreasing solution pH value. Compare to other variables, the pH value is the most significant variable for separation between protein and water.
Flow and fouling in membrane filters: Effects of membrane morphology
NASA Astrophysics Data System (ADS)
Sanaei, Pejman; Cummings, Linda J.
2015-11-01
Membrane filters are widely-used in microfiltration applications. Many types of filter membranes are produced commercially, for different filtration applications, but broadly speaking the requirements are to achieve fine control of separation, with low power consumption. The answer to this problem might seem obvious: select the membrane with the largest pore size and void fraction consistent with the separation requirements. However, membrane fouling (an inevitable consequence of successful filtration) is a complicated process, which depends on many parameters other than membrane pore size and void fraction; and which itself greatly affects the filtration process and membrane functionality. In this work we formulate mathematical models that can (i) account for the membrane internal morphology (internal structure, pore size & shape, etc.); (ii) fouling of membranes with specific morphology; and (iii) make some predictions as to what type of membrane morphology might offer optimum filtration performance.
Evaluation of air samplers and filter materials for collection and recovery of airborne norovirus.
Uhrbrand, K; Koponen, I K; Schultz, A C; Madsen, A M
2018-04-01
The aim of this study was to identify the most efficient sampling method for quantitative PCR-based detection of airborne human norovirus (NoV). A comparative experiment was conducted in an aerosol chamber using aerosolized murine norovirus (MNV) as a surrogate for NoV. Sampling was performed using a nylon (NY) filter in conjunction with four kinds of personal samplers: Gesamtstaubprobenahme sampler (GSP), Triplex-cyclone sampler (TC), 3-piece closed-faced Millipore cassette (3P) and a 2-stage NIOSH cyclone sampler (NIO). In addition, sampling was performed using the GSP sampler with four different filter types: NY, polycarbonate (PC), polytetrafluoroethylene (PTFE) and gelatine (GEL). The sampling efficiency of MNV was significantly influenced by both sampler and filter type. The GSP sampler was found to give significantly (P < 0·05) higher recovery of aerosolized MNV than 3P and NIO. A higher recovery was also found for GSP compared with TC, albeit not significantly. Finally, recovery of aerosolized MNV was significantly (P < 0·05) higher using NY than PC, PTFE and GEL filters. The GSP sampler combined with a nylon filter was found to be the best method for personal filter-based sampling of airborne NoV. The identification of a suitable NoV air sampler is an important step towards studying the association between exposure to airborne NoV and infection. © 2017 The Society for Applied Microbiology.
Erythrocyte membrane alterations as the basis of chlorate toxicity.
Singelmann, E; Wetzel, E; Adler, G; Steffen, C
1984-03-01
The effects of sodium chlorate and of sodium nitrite on human erythrocytes were studied in vitro. Nitrite rapidly oxidised haemoglobin and glutathione; reduction of methaemoglobin (Hbi) by methylene blue was complete during 3 h of incubation with nitrite. With chlorate, a concentration-dependent lag phase was seen before Hbi was formed. After prolonged incubation, Hbi could no longer be reduced with methylene blue. Several other effects were observed that explain the clinical picture of chlorate poisoning which involves haemolysis followed by disseminated intravascular coagulation and renal failure: increased permeability to cations, increased resistance to hypotonic haemolysis and prolonged filtration time through polycarbonate membranes with cylindrical pores of 5 micron diameter. This suggests an increased membrane rigidity due to membrane protein polymerisation, as demonstrated by SDS polyacrylamide gel electrophoresis. Simultaneously, erythrocyte enzymes were inactivated, primarily glucose-6-phosphate dehydrogenase which is necessary for the therapeutic effect of methylene blue. This explains the inefficacy of methylene blue in the treatment of a case of chlorate poisoning that we observed (Arch. Toxicol., 48 (1981) 281).
NASA Technical Reports Server (NTRS)
2003-01-01
Topics covered include: Stable, Thermally Conductive Fillers for Bolted Joints; Connecting to Thermocouples with Fewer Lead Wires; Zipper Connectors for Flexible Electronic Circuits; Safety Interlock for Angularly Misdirected Power Tool; Modular, Parallel Pulse-Shaping Filter Architectures; High-Fidelity Piezoelectric Audio Device; Photovoltaic Power Station with Ultracapacitors for Storage; Time Analyzer for Time Synchronization and Monitor of the Deep Space Network; Program for Computing Albedo; Integrated Software for Analyzing Designs of Launch Vehicles; Abstract-Reasoning Software for Coordinating Multiple Agents; Software Searches for Better Spacecraft-Navigation Models; Software for Partly Automated Recognition of Targets; Antistatic Polycarbonate/Copper Oxide Composite; Better VPS Fabrication of Crucibles and Furnace Cartridges; Burn-Resistant, Strong Metal-Matrix Composites; Self-Deployable Spring-Strip Booms; Explosion Welding for Hermetic Containerization; Improved Process for Fabricating Carbon Nanotube Probes; Automated Serial Sectioning for 3D Reconstruction; and Parallel Subconvolution Filtering Architectures.
Membrane filtration method for enumeration and isolation of Alicyclobacillus spp. from apple juice.
Lee, S-Y; Chang, S-S; Shin, J-H; Kang, D-H
2007-11-01
To evaluate the applicability of filtration membranes for detecting Alicyclobacillus spp. spores in apple juice. Ten types of nitrocellulose membrane filters from five manufacturers were used to collect and enumerate five Alicyclobacillus spore isolates and results were compared to conventional K agar plating. Spore recovery differed among filters with an average recovery rate of 126.2%. Recovery levels also differed among spore isolates. Although significant difference (P < 0.05) in spore sizes existed, no correlation could be determined between spore size and membrane filter recovery rate. Recovery of spores using membrane filtration is dependent on the manufacturer and filter pore size. Correlations between spore recovery rate and spore size could not be determined. Low numbers of Alicyclobacillus spores in juice can be effectively detected using membrane filtration although recovery rate differences exist among different manufacturers. Use of membrane filtration is a simple, fast alternative to the week-long enrichment procedures currently employed in most quality assurance tests.
Electrodeposition at room temperature of amorphous silicon and germanium nanowires in ionic liquid
NASA Astrophysics Data System (ADS)
Martineau, F.; Namur, K.; Mallet, J.; Delavoie, F.; Endres, F.; Troyon, M.; Molinari, M.
2009-11-01
The electrodeposition at room temperature of silicon and germanium nanowires from the air- and water-stable ionic liquid 1-butyl-1-methylpyrrolidinium bis(trifluoromethanesulfonyl)imide (P1,4) containing SiCl4 as Si source or GeCl4 as Ge source is investigated by cyclic voltammetry. By using nanoporous polycarbonate membranes as templates, it is possible to reproducibly grow pure silicon and germanium nanowires of different diameters. The nanowires are composed of pure amorphous silicon or germanium. The nanowires have homogeneous cylindrical shape with a roughness of a few nanometres on the wire surfaces. The nanowires' diameters and lengths well match with the initial membrane characteristics. Preliminary photoluminescence experiments exhibit strong emission in the near infrared for the amorphous silicon nanowires.
21 CFR 175.365 - Vinylidene chloride copolymer coatings for polycarbonate film.
Code of Federal Regulations, 2010 CFR
2010-04-01
... polycarbonate film. 175.365 Section 175.365 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH... chloride copolymer coatings for polycarbonate film. Vinylidene chloride copolymer coatings identified in this section and applied on polycarbonate film may be safely used as food-contact surfaces, in...
Layer by Layer, Nano-particle "Only" Surface Modification of Filtration Membranes
NASA Astrophysics Data System (ADS)
Escobar-Ferrand, Luis
Layer by Layer (LbL) deposition using primarily inorganic silica nanoparticles is employed for the modification of polymeric micro and ultrafiltration (MF/UF) membranes to produce thin film composites (TFC) with potential nanofiltration (NF) and reverse osmosis (RO) capabilities.. A variety of porous substrate membranes with different membrane surface characteristics are employed, but exhibiting in common that wicking of water does not readily occur into the pore structure, including polycarbonate track etched (PCTE), polyethersulfone (PES) and sulfonated PES (SPEES) MF/UF membranes. Both spherical (cationic/anionic) and eccentric elongated (anionic) silica nanoparticles are deposited using conditions similar to those reported by Lee et al. Appropriate selection of the pH's for anionic and cationic particle deposition enables the construction of nanoparticle only layers 100--1200 nm in thickness atop the original membrane substrates. The surface layer thickness varies monotonically with the number of bilayers (anionic/cationic deposition cycles) as expected. The deposition process is optimized to eliminate drying induced cracking and to improve mechanical durability via thickness control and post-deposition hydro-thermal treatment. The hydrodynamic permeability of these TFC membranes is measured to evaluate their performance under typical NF operating conditions using dead-end permeation experiments and their performance compared quantitatively with realistic hydrodynamic models, with favorable results. For track etched polycarbonate MF substrates, surface modification causes a permeability reduction of approximately two orders of magnitude with respect to the bare substrates, to values comparable to those for typical commercial NF membranes. Good quantitative agreement with hydrodynamic models with no adjustable parameters was also established for this case, providing indirect confirmation that the LbL deposited surface layers are largely defect (crack) free. Imaging of our TFC membranes after permeation tests confirmed that no significant mechanical damage resulted, indicating integrity and robustness of the LbL deposited surface layers in typical applications. The selectivity of these novel TFC membranes was also tested using standard "rejection" tests normally used to characterize NF and RO membranes for their capabilities in typical applications, such as water softening or desalination. We report the dextran standards molecular weight "cut-off" (MWCO) using mixed dextrans from 1.5 to 500 KDa in dead-end stir cells, and the percentage of rejection of standard bivalent and monovalent salt solutions using steady cross flow permeation experiments. The results confirm rejection of at least 60% of even the smallest dextrans, an estimated dextran MWCO of 20 KDa, and rejection of 10% and 20% for monovalent (NaCl) and bivalent (MgSO4) salts, respectively, for all the TFC membranes studied, while the unmodified membranes showed no rejection capability at all. The work supports that nanoparticle based LbL surface modification of MF/UF membranes can produce filtration quality media for important water purification applications, such as nanofiltration (NF) softening processes, natural organic matter (NOM) elimination and possibly reverse osmosis (RO) desalination.
Filtering apparatus and method of use
NASA Technical Reports Server (NTRS)
Gavalas, Lillian Susan (Inventor)
2011-01-01
A filtering apparatus comprises a microporous membrane and an actuator. The membrane is positioned to traverse across the hollow interior of a conduit used for the transport of molecules in bulk. In one example, the pores of the membrane comprise a plurality of open-ended carbon nanotubes. The actuator comprises a transducing material such as a polyvinyledene fluoride film that is operatively positioned in contact with the membrane and is capable of propagating acoustic vibration onto the membrane at a particular frequency so as to hasten the movement of the molecules through the membrane. Similarly, a method of filtering water comprises the steps of: (a) sifting molecules of water through the membrane, the pores of the membrane comprising a plurality of carbon nanotubes; and (b) propagating acoustic vibration onto the microporous membrane at a libration frequency of ice so as to hasten movement of the water molecules within the carbon nanotubes.
Development of a filter to prevent infections with spore-forming bacteria in injecting drug users.
Alhusein, Nour; Scott, Jenny; Kasprzyk-Hordern, Barbara; Bolhuis, Albert
2016-12-01
In heroin injectors, there have been a number of outbreaks caused by spore-forming bacteria, causing serious infections such as anthrax or botulism. These are, most likely, caused by injecting contaminated heroin, and our aim was to develop a filter that efficiently removes these bacteria and is also likely to be acceptable for use by people who inject drugs (i.e. quick, simple and not spoil the hit). A prototype filter was designed and different filter membranes were tested to assess the volume of liquid retained, filtration time and efficiency of the filter at removing bacterial spores. Binding of active ingredients of heroin to different types of membrane filters was determined using a highly sensitive analytical chemistry technique. Heroin samples that were tested contained up to 580 bacteria per gramme, with the majority being Bacillus spp., which are spore-forming soil bacteria. To remove these bacteria, a prototype filter was designed to fit insulin-type syringes, which are commonly used by people who inject drugs (PWIDs). Efficient filtration of heroin samples was achieved by combining a prefilter to remove particles and a 0.22 μm filter to remove bacterial spores. The most suitable membrane was polyethersulfone (PES). This membrane had the shortest filtration time while efficiently removing bacterial spores. No or negligible amounts of active ingredients in heroin were retained by the PES membrane. This study successfully produced a prototype filter designed to filter bacterial spores from heroin samples. Scaled up production could produce an effective harm reduction tool, especially during outbreaks such as occurred in Europe in 2009/10 and 2012.
Muhamad, Mimi Suliza; Salim, Mohd Razman; Lau, Woei Jye; Yusop, Zulkifli
2016-06-01
Massive utilization of bisphenol A (BPA) in the industrial production of polycarbonate plastics has led to the occurrence of this compound (at μg/L to ng/L level) in the water treatment plant. Nowadays, the presence of BPA in drinking water sources is a major concern among society because BPA is one of the endocrine disruption compounds (EDCs) that can cause hazard to human health even at extremely low concentration level. Parallel to these issues, membrane technology has emerged as the most feasible treatment process to eliminate this recalcitrant contaminant via physical separation mechanism. This paper reviews the occurrences and effects of BPA toward living organisms as well as the application of membrane technology for their removal in water treatment plant. The potential applications of using polymeric membranes for BPA removal are also discussed. Literature revealed that modifying membrane surface using blending approach is the simple yet effective method to improve membrane properties with respect to BPA removal without compromising water permeability. The regeneration process helps in maintaining the performances of membrane at desired level. The application of large-scale membrane process in treatment plant shows the feasibility of the technology for removing BPA and possible future prospect in water treatment process.
NASA Astrophysics Data System (ADS)
Schiperski, Ferry; Zirlewagen, Johannes; Hillebrand, Olav; Scheytt, Traugott; Licha, Tobias
2013-04-01
The studied karst spring 'Gallusquelle' is located on the Swabian Alb in Southwest Germany. The catchment area of the 'Gallusquelle' measures about 45 km². An average annual discharge of 0.5 m³/s serves drinking water to about 40,000 people via a waterworks. The study is part of the research project 'AGRO' (www.projekt-agro.de). The main objective of the project 'AGRO' is to develop a tool for the process-based risk management of micropollutants and pathogens in rural karst aquifers on catchment scale. As particle related transport could play an important role for micropollutants and pathogens, the characterization of particles in the spring water is one focus of this work. Furthermore we will attempt to correlate physicochemical parameters with the characteristics of particles in the spring water in order to enhance the knowledge of the transport mechanisms within the karst aquifer. For the measurement of the particle concentration and the particle size distribution the CIS 1 (GALAI) was used. The system works in a range of 0.5 to 150 µm with a resolution of at least 0.5 µm. The measurement is based on time-of-transition method using a laser beam. The turbidity was measured with an ULTRATURB PLUS (DR.LANGE) and a Fluorometer (GGUN-FL30, ALBILLIA), both working with scattering light method. To verify these measurements we used a portable turbidimeter (2100P IS PORTABLE TURBIDIMETER, HACH) working with the ratio of the signals from the scattered and the transmitted light. Temperature and electrical conductivity where also measured with the GGUN-FL30, whereby the electrical conductivity was verified with a portable multimeter (HQ 40D, HACH). Discharge, pH, water hardness, anion- and cation concentration, total organic carbon (TOC) and dissolved organic carbon (DOC) were also determined. To characterize the particles, the spring water was filtered onsite and the filter cake was analyzed in the laboratory. For SEM (scanning electron microscopy) including EDAX (energy dispersive X-ray spectroscopy) the water was filtered through PC membrane filters (∅=25mm) using a polycarbonate syringe. For X-ray diffraction the water was filtered through CA membrane filters (∅=142 mm) using a stainless steel pressure holder and a peristaltic pump. Both filters had an average pore size of 0.45 µm. Also we have analyzed sediments that where collected downstream of the online measurements and in the raw water tank of a waterworks that is located about 250 m downstream of the spring. During an average discharge the turbidity and the number of particles are around the limit of detection. Both increase with increasing discharge while the average particle size does not increase until a considerably higher-than-average discharge is reached. Particles in the size range of 0.5 - 2.0 µm display the main numeric amount (70 - 100 %) of the measurable particles under present discharge conditions. Only under high discharge conditions particles sizes > 5 µm increase significantly. Particles > 20 µm are rare during the whole period of measurement. In contrast to other works we include mineralogical studies of the particles in the spring water. Thus we can examine the relevance of mineralogical properties of the particles for the transport of micropollutants. Actual results of XRD analyses indicate that calcite, quartz and clay minerals dominate the turbidity. EDAX analyses with SEM confirm these measurements.
Band-gap tunable dielectric elastomer filter for low frequency noise
NASA Astrophysics Data System (ADS)
Jia, Kun; Wang, Mian; Lu, Tongqing; Zhang, Jinhua; Wang, Tiejun
2016-05-01
In the last decades, diverse materials and technologies for sound insulation have been widely applied in engineering. However, suppressing the noise radiation at low frequency still remains a challenge. In this work, a novel membrane-type smart filter, consisting of a pre-stretched dielectric elastomer membrane with two compliant electrodes coated on the both sides, is presented to control the low frequency noise. Since the stiffness of membrane dominates its acoustic properties, sound transmission band-gap of the membrane filter can be tuned by adjusting the voltage applied to the membrane. The impedance tube experiments have been carried out to measure the sound transmission loss (STL) of the filters with different electrodes, membrane thickness and pre-stretch conditions. The experimental results show that the center frequency of sound transmission band-gap mainly depends on the stress in the dielectric elastomer, and a large band-gap shift (more than 60 Hz) can be achieved by tuning the voltage applied to the 85 mm diameter VHB4910 specimen with pre-stretch {λ }0=3. Based on the experimental results and the assumption that applied electric field is independent of the membrane behavior, 3D finite element analysis has also been conducted to calculate the membrane stress variation. The sound filter proposed herein may provide a promising facility to control low frequency noise source with tonal characteristics.
Polycarbonate Bottle Use and Urinary Bisphenol A Concentrations
Carwile, Jenny L.; Luu, Henry T.; Bassett, Laura S.; Driscoll, Daniel A.; Yuan, Caterina; Chang, Jennifer Y.; Ye, Xiaoyun; Calafat, Antonia M.; Michels, Karin B.
2009-01-01
Background Bisphenol A (BPA) is a high-production-volume chemical commonly used in the manufacture of polycarbonate plastic. Low-level concentrations of BPA in animals and possibly in humans may cause endocrine disruption. Whether ingestion of food or beverages from polycarbonate containers increases BPA concentrations in humans has not been studied. Objectives We examined the association between use of polycarbonate beverage containers and urinary BPA concentrations in humans. Methods We conducted a nonrandomized intervention of 77 Harvard College students to compare urinary BPA concentrations collected after a washout phase of 1 week to those taken after an intervention week during which most cold beverages were consumed from polycarbonate drinking bottles. Paired t-tests were used to assess the difference in urinary BPA concentrations before and after polycarbonate bottle use. Results The geometric mean urinary BPA concentration at the end of the washout phase was 1.2 μg/g creatinine, increasing to 2.0 μg/g creatinine after 1 week of polycarbonate bottle use. Urinary BPA concentrations increased by 69% after use of polycarbonate bottles (p < 0.0001). The association was stronger among participants who reported ≥ 90% compliance (77% increase; p < 0.0001) than among those reporting < 90% compliance (55% increase; p = 0.03), but this difference was not statistically significant (p = 0.54). Conclusions One week of polycarbonate bottle use increased urinary BPA concentrations by two-thirds. Regular consumption of cold beverages from polycarbonate bottles is associated with a substantial increase in urinary BPA concentrations irrespective of exposure to BPA from other sources. PMID:19750099
Shen, Ying-Jie; Wu, Guang-Xia; Fan, Yao-Bo; Zhong, Hui; Wu, Lin-Lin; Zhang, Shao-Lai; Zhao, Xian-Hong; Zhang, Wei-Jun
2007-01-01
Using the surface of poly (sulfone) hollow fiber membrane segments as grafted layer, the hydrophilic acrylamide chain was grafted on by UV-photoinduced grafting polymerization. The gained improvement of surface wettability for the modified membrane was tested by measuring the contact-angle as well as FTIR spectra. Then correlation between the hydrophilic ability of support material and the biofilm adherence ability was demonstrated by comparing the pollutant removal rates from urban wastewater via two identical lab-scale up-flow biological aerated filters, one employed the surface wettability modified poly (sulfone) hollow fiber membrane segment as biofilm carrier and the other employed unmodified membrane segment as biofilm carrier. The experimental results showed that under the conditions of influent flux 5 L/h, hydraulic retention time 9 h and gas to liquid ratio (G/L) 10:1, the removal rates of chemical oxygen demand (COD) and ammonium nitrogen (NH4(+)-N) for the modified packing filter and the unmodified packing filter was averaged at 83.64% and 96.25%, respectively, with the former filter being 5%-20% more than the latter. The effluent concentration of COD, NH4(+)-N and turbidity for the modified packing filter was 25.25 mg/L, 2 mg/L and 8 NTU, respectively. Moreover, the ammonium nitrogen removal performance of the filter packing the modified PSF was compared with the other bioreactor packing of an efficient floating medium. The biomass test indicated that the modified membrane matrixes provided better specific adhesion (3310-5653 mg TSS/L support), which gave a mean of 1000 mg TSS/L more than the unmodified membrane did. In addition, the phenomenon of simultaneous denitrification on the inner surface of the support and nitrification on the outer surface was found in this work.
Deashing of coal liquids with ceramic membrane microfiltration and diafiltration
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bishop, B.; Goldsmith, R.
1995-12-31
Removal of mineral matter from liquid hydrocarbons derived from the direct liquefaction of coal is required for product acceptability. Current methods include critical solvent deashing (Rose{sup {reg_sign}} process from Kerr-McGee) and filtration (U.S. Filter leaf filter as used by British Coal). These methods produce ash reject streams containing up to 15% of the liquid hydrocarbon product. Consequently, CeraMem proposed the use of low cost, ceramic crossflow membranes for the filtration of coal liquids bottoms to remove mineral matter and subsequent diafiltration (analogous to cake washing in dead-ended filtration) for the removal of coal liquid from the solids stream. The usemore » of these ceramic crossflow membranes overcomes the limitations of traditional polymeric crossflow membranes by having the ability to operate at elevated temperature and to withstand prolonged exposure to hydrocarbon and solvent media. In addition, CeraMem`s membrane filters are significantly less expensive than competitive ceramic membranes due to their unique construction. With these ceramic membrane filters, it may be possible to reduce the product losses associated with traditional deashing processes at an economically attractive cost. The performance of these ceramic membrane microfilters is discussed.« less
Comparison of Various Brands of Membrane Filters for Their Ability to Recover Fungi from Water
Qureshi, A. A.; Dutka, B. J.
1976-01-01
Five brands of ethylene oxide- and autoclave-sterilized membrane filters were examined for their ability to recover fungi from natural waters. Results showed that the recovery on Gelman membranes was consistently higher than on the other brands tested. PMID:984821
Method for efficient recovery of high-purity polycarbonates from electronic waste.
Weeden, George S; Soepriatna, Nicholas H; Wang, Nien-Hwa Linda
2015-02-17
More than one million tons of polycarbonates from waste electrical and electronic equipment are consigned to landfills at an increasing rate of 3-5% per year. Recycling the polymer waste should have a major environmental impact. Pure solvents cannot be used to selectively extract polycarbonates from mixtures of polymers with similar properties. In this study, selective mixed solvents are found using guidelines from Hansen solubility parameters, gradient polymer elution chromatography, and solubility tests. A room-temperature sequential extraction process using two mixed solvents is developed to recover polycarbonates with high yield (>95%) and a similar purity and molecular weight distribution as virgin polycarbonates. The estimated cost of recovery is less than 30% of the cost of producing virgin polycarbonates from petroleum. This method would potentially reduce raw materials from petroleum, use 84% less energy, reduce emission by 1-6 tons of CO2 per ton of polycarbonates, and reduce polymer accumulation in landfills and associated environmental hazards.
Dolfus, Claire; Piton, Nicolas; Toure, Emmanuel
2015-01-01
Circulating tumor cells (CTCs) arise from primary or secondary tumors and enter the bloodstream by active or passive intravasation. Given the low number of CTCs, enrichment is necessary for detection. Filtration methods are based on selection of CTCs by size using a filter with 6.5 to 8 µm pores. After coloration, collected CTCs are evaluated according to morphological criteria. Immunophenotyping and fluorescence in situ hybridization techniques may be used. Selected CTCs can also be cultivated in vitro to provide more material. Analysis of genomic mutations is difficult because it requires adapted techniques due to limited DNA materials. Filtration-selected CTCs have shown prognostic value in many studies but multicentric validating trials are mandatory to strengthen this assessment. Other clinical applications are promising such as follow-up, therapy response prediction and diagnosis. Microfluidic emerging systems could optimize filtration-selected CTCs by increasing selection accuracy. PMID:26543334
Poppe, L.J.; Commeau, J.A.; Pense, G.M.
1989-01-01
Silver metal-membrane filters are commonly used as substrates in the preparation of oriented clay-mineral specimens for X-ray powder diffraction (XRD). They are relatively unaffected by organic solvent treatments and specimens can be prepared rapidly. The filter mounts are adaptable to automatic sample changers, have few discrete reflections at higher 20 angles, and, because of the high atomic number of silver, produce a relatively low overall background compared with other membrane filters, such as cellulose (Poppe and Hathaway, 1979). The silver metal-membrane filters, however, present some problems after heat treatment if either the filters or the samples contain significant amounts of chlorine. At elevated temperature, the chloride ions react with the silver substrate to form crystalline compounds. These compounds change the mass-absorption coefficient of the sample, reducing peak intensities and areas and, therefore, complicating the semiquantitative estimation of clay minerals. A simple procedure that eliminates most of the chloride from a sample and the silver metal-membrane substrate is presented here.
Metal-Organic Framework (MOF) Nanorods, Nanotubes, and Nanowires.
Arbulu, Roberto C; Jiang, Ying-Bing; Peterson, Eric J; Qin, Yang
2018-05-14
New mechanisms for the controlled growth of one-dimensional (1D) metal-organic framework (MOF) nano- and superstructures under size-confinement and surface-directing effects have been discovered. Through applying interfacial synthesis templated by track-etched polycarbonate (PCTE) membranes, congruent polycrystalline zeolitic imidazolate framework-8 (ZIF-8) solid nanorods and hollow nanotubes were found to form within 100 nm membrane pores, while single crystalline ZIF-8 nanowires grew inside 30 nm pores, all of which possess large aspect ratios up to 60 and show preferential crystal orientation with the {100} planes aligned parallel to the long axis of the pore. Our findings provide a generalizable method for controlling size, morphology, and lattice orientation of MOF nanomaterials. © 2018 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.
DEVELOPMENT OF A LAMINATED DISK FOR THE SPIN TEK ROTARY MICROFILTER
DOE Office of Scientific and Technical Information (OSTI.GOV)
Herman, D.
2011-06-03
Funded by the Department of Energy Office of Environmental Management, EM-31, the Savannah River National Laboratory (SRNL) partnered with SpinTek Filtration{trademark} to develop a filter disk that would withstand a reverse pressure or flow during operation of the rotary microfilter. The ability to withstand a reverse pressure and flow eliminates a potential accident scenario that could have resulted in damage to the filter membranes. While the original welded filter disks have been shown to withstand and reverse pressure/flow in the static condition, the filter disk design discussed in this report will allow a reverse pressure/flow while the disks are rotating.more » In addition, the laminated disk increases the flexibility during filter startup and cleaning operations. The new filter disk developed by SRNL and SpinTek is manufactured with a more open structure significantly reducing internal flow restrictions in the disk. The prototype was tested at the University of Maryland and demonstrated to withstand the reverse pressure due to the centrifugal action of the rotary filter. The tested water flux of the disk was demonstrated to be 1.34 gpm in a single disk test. By comparison, the water flux of the current disk was 0.49 gpm per disk during a 25 disk test. The disk also demonstrated rejection of solids by filtering a 5 wt % Strontium Carbonate slurry with a filtrate clarity of less the 1.4 Nephelometric Turbidity Units (NTU) throughout the two hour test. The Savannah River National Laboratory (SRNL) has been working with SpinTek Filtration{trademark} to adapt the rotary microfilter for radioactive service in the Department of Energy (DOE) Complex. One potential weakness is the loose nature of the membrane on the filter disks. The current disk is constructed by welding the membrane at the outer edge of the disk. The seal for the center of the membrane is accomplished by an o-ring in compression for the assembled stack. The remainder of the membrane is free floating on the disk. This construction requires that a positive pressure be applied to the rotary filter tank to prevent the membrane from rising from the disk structure and potentially contacting the filter turbulence promoter. In addition, one accident scenario is a reverse flow through the filtrate line due to mis-alignment of valves resulting in the membrane rising from the disk structure. The structural integrity of the current disk has been investigated, and shown that the disk can withstand a significant reverse pressure in a static condition. However, the disk will likely incur damage if the filter stack is rotated during a reverse pressure. The development of a laminated disk would have several significant benefits for the operation of the rotary filter including the prevention of a compromise in filter disk integrity during a reverse flow accident, increasing operational flexibility, and increasing the self cleaning ability of the filter. A laminated disk would allow the filter rotor operation prior to a positive pressure in the filter tank. This would prevent the initial dead-head of the filter and prevent the resulting initial filter cake buildup. The laminated disk would allow rotor operation with cleaning fluid, eliminating the need for a recirculation pump. Additionally, a laminated disk would allow a reverse flow of fluid through the membrane pores removing trapped particles.« less
Recio-Spinoso, Alberto; Fan, Yun-Hui; Ruggero, Mario A
2011-05-01
Basilar-membrane responses to white Gaussian noise were recorded using laser velocimetry at basal sites of the chinchilla cochlea with characteristic frequencies near 10 kHz and first-order Wiener kernels were computed by cross correlation of the stimuli and the responses. The presence or absence of minimum-phase behavior was explored by fitting the kernels with discrete linear filters with rational transfer functions. Excellent fits to the kernels were obtained with filters with transfer functions including zeroes located outside the unit circle, implying nonminimum-phase behavior. These filters accurately predicted basilar-membrane responses to other noise stimuli presented at the same level as the stimulus for the kernel computation. Fits with all-pole and other minimum-phase discrete filters were inferior to fits with nonminimum-phase filters. Minimum-phase functions predicted from the amplitude functions of the Wiener kernels by Hilbert transforms were different from the measured phase curves. These results, which suggest that basilar-membrane responses do not have the minimum-phase property, challenge the validity of models of cochlear processing, which incorporate minimum-phase behavior. © 2011 IEEE
Green, Barbara L.; Clausen, Elizabeth; Litsky, Warren
1975-01-01
Fecal coliform recoveries were determined for six types of membrane filters using 65 nonchlorinated water samples. Results showed that the membranes could be ranked in order of decreasing recovery as follows: Millipore HC > Gelman > Johns-Manville ∼ Sartorius > Millipore HA > Schleicher & Schuell. PMID:1103735
Bacteria/virus filter membrane
NASA Technical Reports Server (NTRS)
Lysaght, M. S.; Goodwin, F.; Roebelen, G.
1977-01-01
Hollow acrylate fiber membrane that filters bacterial and viral organisms can be used with closed-cycle life-support systems for underwater habitations or laboratories. Membrane also has applications in fields of medicine, gnotobiotics, pharmaceutical production, and industries and research facilities that require sterile water. Device eliminates need for strong chemicals or sterilizing agents, thereby reducing costs.
Nonyellowing Polycarbonate for Outdoor Use
NASA Technical Reports Server (NTRS)
Gupta, A.; Liang, R. H.; Yavrouian, A.; Clayton, A.
1985-01-01
Two-step photochemical process prevents yellowing of polycarbonate plastics. Use of polycarbonate plastics growing in windows, aircraft glazing, and streetlight globes. New photochemical process causes formation of stabilizers bound to polymer chains and therefore cannot be leached out.
NASA Astrophysics Data System (ADS)
China, S.; Mazzoleni, C.; Dubey, M. K.; Chakrabarty, R. K.; Moosmuller, H.; Onasch, T. B.; Herndon, S. C.
2010-12-01
We present an analysis of morphological characteristics of atmospheric aerosol collected during the MILAGRO (Megacity Initiative: Local and Global Research Observations) field campaign that took place in Mexico City in March 2006. The sampler was installed on the Aerodyne mobile laboratory. The aerosol samples were collected on nuclepore clear polycarbonate filters mounted in Costar pop-top membrane holders. More than one hundred filters were collected at different ground sites with different atmospheric and geographical characteristics (urban, sub-urban, mountain-top, industrial, etc.) over a month period. Selected subsets of these filters were analyzed for aerosol morphology using a scanning electron microscope and image analysis techniques. In this study we investigate spatial and temporal variations of aerosol shape descriptors, morphological parameters, and fractal dimension. We also compare the morphological results with other aerosol measurements such as aerosol optical properties(scattering and absorption) and size distribution data. Atmospheric aerosols have different morphological characteristics depending on many parameters such as emission sources, atmospheric formation pathways, aging processes, and aerosol mixing state. The aerosol morphology influences aerosol chemical and mechanical interactions with the environment, physical properties, and radiative effects. In this study, ambient aerosol particles have been classified in different shape groups as spherical, irregularly shaped, and fractal-like aggregates. Different morphological parameters such as aspect ratio, roundness, feret diameter, etc. have been estimated for irregular shaped and spherical particles and for different kinds of soot particles including fresh soot, collapsed and coated soot. Fractal geometry and image processing have been used to obtain morphological characteristics of different soot particles. The number of monomers constituting each aggregate and their diameters were measured and used to estimate an ensemble three-dimensional (3-d) fractal dimension. One-dimensional (1-d) and two-dimensional (2-d) fractal geometries have been measured using a power-law scaling relationship between 1-d and 2-d properties of projected images. Temporal variations in fractal dimension of soot-like aggregates have been observed at the mountaintop site and spatial variation of fractal dimension and other morphological descriptors of different shaped particles have been investigated for the different ground sites.
Ao, Xiaoping; Stenken, Julie A
2003-09-01
Microdialysis relative recovery (RR) enhancement using different water-soluble, epichlorohydrin-based cyclodextrin polymers (CD-EPS) was studied in vitro for different analytes, amitryptiline, carbamazepine, hydroquinone, ibuprofen, and 4-nitrophenol. When compared to the native CDs (alpha, beta, and gamma) on a per mole basis, the CD-EPS enhanced microdialysis RR was either statistically greater or the same. beta-CD-EPS was more highly retained than native beta-CD by a 20 000 Da molecular weight cutoff (MWCO) polycarbonate membrane, but showed no statistical difference for loss across a 100 000 Da MWCO polyethersulfone membrane (PES). When the same weight percent of beta-CD or beta-CD-EPS was included in the microdialysis perfusion fluid, the beta-CD-EPS produced a higher microdialysis RR than native beta-CD for all analytes across the PES membrane. However, enhancements for the PC membrane were statistically insignificant when beta-CD and beta-CD-EPS were compared on a per mole basis. These results suggest that CD-EPS may be used as effective enhancement agents during microdialysis sampling and for some membranes provide the additional advantage of being retained more than native CDs.
Li, Manqing; Feng, Yingnan; Wang, Kaiyu; Yong, Wai Fen; Yu, Liya; Chung, Tai-Shung
2017-09-05
Severe air pollution has become a global concern, and there is a pressing need to develop effective and efficient air filters for removing airborne particulate matters (PMs). In this work, a highly permeable poly(ether sulfone) (PES) based hollow fiber membrane was developed via a one-step dry-jet wet spinning. For the first time, a hollow fiber membrane was used in removing the ultrafine particles (PMs with aerodynamic equivalent diameters of less than 100 nm) in PM 2.5 . The novel air filter was designed to possess the synergistic advantages of porous filters and fibrous filters with a sievelike outer surface and a fibrouslike porous substrate. A filtration efficiency of higher than 99.995% could be easily achieved when the self-support hollow fiber was challenged with less than 300 nm particulates. Without losses of the structural advantages, we have demonstrated that the permeation properties of the hollow fiber membrane can be facilely tailored via manipulation of the dope and bore fluid formulations. Various cleaning strategies were explored to regenerate the membrane performance after fouling. Both water rinse and backwash showed effectiveness to restore the membrane permeance for repetitive usage.
Bisphenol A is released from used polycarbonate animal cages into water at room temperature
Howdeshell, Kembra L.; Peterman, Paul H.; Judy, Barbara M.; Taylor, Julia A.; Orazio, Carl E.; Ruhlen, Rachel L.; vom Saal, Frederick S.; Welshons, Wade V.
2003-01-01
Bisphenol A (BPA) is a monomer with estrogenic activity that is used in the production of food packaging, dental sealants, polycarbonate plastic, and many other products. The monomer has previously been reported to hydrolyze and leach from these products under high heat and alkaline conditions, and the amount of leaching increases as a function of use. We examined whether new and used polycarbonate animal cages passively release bioactive levels of BPA into water at room temperature and neutral pH. Purified water was incubated at room temperature in new polycarbonate and polysulfone cages and used (discolored) polycarbonate cages, as well as control (glass and used polypropylene) containers. The resulting water samples were characterized with gas chromatography/mass spectrometry (GC/MS) and tested for estrogenic activity using an MCF-7 human breast cancer cell proliferation assay. Significant estrogenic activity, identifiable as BPA by GC/MS (up to 310 micro g/L), was released from used polycarbonate animal cages. Detectable levels of BPA were released from new polycarbonate cages (up to 0.3 micro g/L) as well as new polysulfone cages (1.5 micro g/L), whereas no BPA was detected in water incubated in glass and used polypropylene cages. Finally, BPA exposure as a result of being housed in used polycarbonate cages produced a 16% increase in uterine weight in prepubertal female mice relative to females housed in used polypropylene cages, although the difference was not statistically significant. Our findings suggest that laboratory animals maintained in polycarbonate and polysulfone cages are exposed to BPA via leaching, with exposure reaching the highest levels in old cages.
Bayer, C; Follmann, M; Melin, T; Wintgens, T; Larsson, K; Almemark, M
2010-01-01
Many phenolic compounds show high boiling points, low molecular weights, moderate polarities or high toxicities. Therefore, conventional wastewater treatment is limited or expensive. Recycling of the separated compounds is often not possible. But, if liquid-liquid reactive extraction is linked to a non-porous membrane, some or all of the above mentioned limitations may be overcome. The key element is a composite membrane with a dense, hydrophobic top layer which avoids the mixing of the two aqueous fluid streams. The dilute phenol stream is one of them, the other is caustic soda as stripping solvent. Since the basics of this technology have been discussed before, the scope of this study is to facilitate process implementation and integration. To this end, a life cycle assessment framework is used to identify the optimal equipment size for the treatment of wastewater that may, for example, originate from the production of polycarbonate. Limiting for this application is not the environmental performance though, but most likely process economics.
EFFECTS OF OZONATION ON THE PERMEATE FLUX OF NANOCRYSTALLINE CERAMIC MEMBRANES. (R830908)
Titania membranes, with a molecular weight cut-off of 15 kD were used in an ozonation/membrane system that was fed with water from Lake Lansing, which had been pre-filtered through a 0.45 �m glass fiber filter. The application of ozone gas prior to filtration resulted in signi...
Assessment of nylon 6, 6 nanofibre membrane for microalgae harvesting
NASA Astrophysics Data System (ADS)
Azizo, Amar Shafrin; Wirzal, Mohd Dzul Hakim; Bilad, Muhammad Roil; Yusoff, Abdull Rahim Mohd
2017-10-01
Pressure driven membrane processes have been proven suitable for the separation of microorganisms in many of biotechnical applications. In this paper, we report the preparation and characterization of a novel nylon 6, 6 nanofibers membranes and applied it for filtration of Chlorella vulgaris broth. Its performance is compared with a phase inverted polyvinylidene fluoride (PVDF) membrane, an established membrane material for this application. The tests on the filterability of both membranes and their harvesting efficiency were conducted. Results show that nanofiber membrane is more hydrophilic (contact angle of zero), and has 45% higher surface pore size and 20% surface pore population that contribute significantly into its higher clean water permeability (of 1018 and 493 l/m2hbar for nanofiber and PVDF membranes respectively). Filterability results show that nanofiber membrane has superior advantages over the phase inverted one: 2-5 times higher in productivity while maintaining similar rejection of 92%. Those results were consistent for three independent filterability tests. This finding confirms the potential application of nanofiber membrane. However, further development with respect to improving its mechanical strength and its ability to be assembled into a membrane module should be critical to serve its promise in this particular application.
Use of piracetam improves sickle cell deformability in vitro and in vivo.
Gini, E K; Sonnet, J
1987-01-01
Microsieving diluted suspensions of oxygenated sickle cell anaemia (HbSS) cells on polycarbonate filters shows that piracetam improves the red cell deformability in vitro. In vivo an oral intake of 160 mg/kg/day divided in four doses enhances the HbSS cell deformability as actively as it does in in vitro experiments. The drug is also able partially to restore the impaired deformability of physiologically deoxygenated HbSS cells. These findings are consistent with the results of clinical trials, which show that continuous treatment with piracetam reduces the incidence of vaso-occlusive crises in patients with sickle cell disease. PMID:3818978
Wear, Keith A
2010-10-01
The presence of two longitudinal waves in porous media is predicted by Biot's theory and has been confirmed experimentally in cancellous bone. When cancellous bone samples are interrogated in through-transmission, these two waves can overlap in time. Previously, the Modified Least-Squares Prony's (MLSP) method was validated for estimation of amplitudes, attenuation coefficients, and phase velocities of fast and slow waves, but tended to overestimate phase velocities by up to about 5%. In the present paper, a pre-processing chirp filter to mitigate the phase velocity bias is derived. The MLSP/chirp filter (MLSPCF) method was tested for decomposition of a 500 kHz-center-frequency signal containing two overlapping components: one passing through a low-density-polyethylene plate (fast wave) and another passing through a cancellous-bone-mimicking phantom material (slow wave). The chirp filter reduced phase velocity bias from 100 m/s (5.1%) to 69 m/s (3.5%) (fast wave) and from 29 m/s (1.9%) to 10 m/s (0.7%) (slow wave). Similar improvements were found for 1) measurements in polycarbonate (fast wave) and a cancellous-bone-mimicking phantom (slow wave), and 2) a simulation based on parameters mimicking bovine cancellous bone. The MLSPCF method did not offer consistent improvement in estimates of attenuation coefficient or amplitude.
Mänttäri, M; Nyström, M
2004-01-01
Ultra- and nanofiltration with high shear CR-filters have been utilized for cleaning of clear filtrates and effluents from the pulp and paper industry. The aim was to find out how different nanofiltration membranes operate at high shear conditions. The filtration efficiency of the membranes was evaluated by measuring flux, retention and fouling at various recovery and pH conditions. High fluxes (approximately 100 L/(m2h)) for nanofiltration membranes were measured when circulation waters from the paper machine were filtered at neutral conditions. In the filtration of discharge of external activated sludge treatment plants we measured fluxes around 150 L/(m2h) even at a concentration factor of 12. The best NF membranes removed over 80% of the organic carbon and of the conductivity and almost completely eliminated the color. With acidic waters fluxes and retentions were significantly lower. The NF270 membrane from Dow and the Desal-5 membranes from Osmonics had the highest flux and retention properties. However, the Desal-5 membrane lost its retention properties slowly, which restricts its use in the high shear CR-filter. CR-nanofiltration can be used in the pulp and paper industry without feed pre-treatment by ultrafiltration. This increases the attractiveness of high shear CR-nanofiltration.
Mayhead, Elyssia; Llewellyn, Carole A.; Fuentes-Grünewald, Claudio
2018-01-01
The nutrient removal efficiency of Chlorella vulgaris cultivated in domestic wastewater was investigated, along with the potential to use membrane filtration as a pre-treatment tool during the wastewater treatment process. Chlorella vulgaris was batch cultivated for 12 days in a bubble column system with two different wastewater treatments. Maximum uptake of 94.18% ammonium (NH4-N) and 97.69% ortho-phosphate (PO4-P) occurred in 0.2 μm membrane filtered primary wastewater. Membrane filtration enhanced the nutrient uptake performance of C. vulgaris by removing bacteria, protozoa, colloidal particles and suspended solids, thereby improving light availability for photosynthesis. The results of this study suggest that growing C. vulgaris in nutrient rich membrane filtered wastewater provides an option for domestic wastewater treatment to improve the quality of the final effluent. PMID:29351200
NASA Astrophysics Data System (ADS)
Lin, Yuehe; Wen, Jenny; Fan, Xiang; Matson, Dean W.; Smith, Richard D.
1999-08-01
A microfabricated device for isoelectric focusing (IEF) incorporating an optimized electrospray ionization (ESI) tip was constructed on polycarbonate plates using a laser micromachining technique. The separation channels on an IEF chip were 16 cm long, 50 micrometers wide and 30 micrometers deep. Electrical potentials used for IEF focusing and electrospray were applied through platinum electrodes placed in the buffer reservoirs, and which were isolated from the separation channel by molecular porous membranes. On-line ESI produced directly from a sharp `tip' on the microchip was evaluated. The results indicate that this design can produce a stable electrospray that is further improved and made more flexible with the assistance of sheath gas and sheath liquid. Error analysis of the spectral data shows that the standard deviation in signal intensity for an analyte peak was less than approximately 5% over 3 hours. The production of stable electrosprays directly from microchip IEF devices represents a step towards easily- fabricated microanalytical devices. IEF separations of protein mixtures were demonstrated for uncoated polycarbonate microchips. On-line IEF/ESI-MS was demonstrated using the microfabricated chip with an ion-trap ESI mass spectrometer for characterization of protein mixtures.
Nakazawa, Kentaro; Hasegawa, Hiroyuki; Nakagawa, Yoji; Terao, Michinori; Matsuyama, Tohey
2005-11-01
Listeria monocytogenes infiltrated the reticulate structure of a membrane filter and passed through a filter with pore sizes of 0.45 microm and 0.2 microm in 6 to 24 h and 5 to 6 days, respectively. Flagellar motility and expansive pressure generated by the growing bacterial population were indicated as the driving forces of infiltration.
Tian, Mingliang; Wang, Jinguo; Kurtz, James; Mallouk, Thomas E; Chan, M H W
2003-07-01
Metallic nanowires (Au, Ag, Cu, Ni, Co, and Rh) with an average diameter of 40 nm and a length of 3-5 μm have been fabricated by electrodeposition in the pores of track-etched polycarbonate membranes. Structural characterizations by transmission electron microscopy (TEM) and electron diffraction showed that nanowires of Au, Ag, and Cu are single-crystalline with a preferred [111] orientation, whereas Ni, Co, and Rh wires are polycrystalline. Possible mechanisms responsible for nucleation and growth for single-crystal noble metals versus polycrystalline group VIII-B metals are discussed.
Gas stream clean-up filter and method for forming same
Mei, Joseph S.; DeVault, James; Halow, John S.
1993-01-01
A gas cleaning filter is formed in-situ within a vessel containing a fluidizable bed of granular material of a relatively large size fraction. A filter membrane provided by a porous metal or ceramic body or such a body supported a perforated screen on one side thereof is coated in-situ with a layer of the granular material from the fluidized bed by serially passing a bed-fluidizing gas stream through the bed of granular material and the membrane. The layer of granular material provides the filtering medium for the combined membrane-granular layer filter. The filter is not blinded by the granular material and provides for the removal of virtually all of the particulates from a process gas stream. The granular material can be at least partially provided by a material capable of chemically reacting with and removing sulfur compounds from the process gas stream. Low level radioactive waste containing organic material may be incinerated in a fluidized bed in communication with the described filter for removing particulates from the gaseous combustion products.
A dense cell retention culture system using stirred ceramic membrane reactor.
Suzuki, T; Sato, T; Kominami, M
1994-11-20
A novel reactor design incorporating porous ceramic tubes into a stirred jar fermentor was developed. The stirred ceramic membrane reactor has two ceramic tubular membrane units inside the vessel and maintains high filtration flux by alternating use for filtering and recovering from clogging. Each filter unit was linked for both extraction of culture broth and gas sparging. High permeability was maintained for long periods by applying the periodical control between filtering and air sparging during the stirred retention culture of Saccharomyces cerevisiae. The ceramic filter aeration system increased the k(L)a to about five times that of ordinary gas sparing. Using the automatic feeding and filtering system, cell mass concentration reached 207 g/L in a short time, while it was 64 g/L in a fed-batch culture. More than 99% of the growing cells were retained in the fermentor by the filtering culture. Both yield and productivity of cells were also increased by controlling the feeding of fresh medium and filtering the supernatant of the dense cells culture. (c) 1994 John Wiley & Sons, Inc.
Fernández, Jorge G; Almeida, César A; Fernández-Baldo, Martín A; Felici, Emiliano; Raba, Julio; Sanz, María I
2016-01-01
Bactericidal water filters were developed. For this purpose, nitrocellulose membrane filters were impregnated with different biosynthesized silver nanoparticles. Silver nanoparticles (AgNPs) from Aspergillus niger (AgNPs-Asp), Cryptococcus laurentii (AgNPs-Cry) and Rhodotorula glutinis (AgNPs-Rho) were used for impregnating nitrocellulose filters. The bactericidal properties of these nanoparticles against Escherichia coli, Enterococcus faecalis and Pseudomona aeruginosa were successfully demonstrated. The higher antimicrobial effect was observed for AgNPs-Rho. This fact would be related not only to the smallest particles, but also to polysaccharides groups that surrounding these particles. Moreover, in this study, complete inhibition of bacterial growth was observed on nitrocellulose membrane filters impregnated with 1 mg L(-1) of biosynthesized AgNPs. This concentration was able to reduce the bacteria colony count by over 5 orders of magnitude, doing suitable for a water purification device. Copyright © 2015 Elsevier B.V. All rights reserved.
Modeling of submicrometer aerosol penetration through sintered granular membrane filters.
Marre, Sonia; Palmeri, John; Larbot, André; Bertrand, Marielle
2004-06-01
We present a deep-bed aerosol filtration model that can be used to estimate the efficiency of sintered granular membrane filters in the region of the most penetrating particle size. In this region the capture of submicrometer aerosols, much smaller than the filter pore size, takes place mainly via Brownian diffusion and direct interception acting in synergy. By modeling the disordered sintered grain packing of such filters as a simple cubic lattice, and mapping the corresponding 3D connected pore volume onto a discrete cylindrical pore network, the efficiency of a granular filter can be estimated, using new analytical results for the efficiency of cylindrical pores. This model for aerosol penetration in sintered granular filters includes flow slip and the kinetics of particle capture by the pore surface. With a unique choice for two parameters, namely the structural tortuosity and effective kinetic coefficient of particle adsorption, this semiempirical model can account for the experimental efficiency of a new class of "high-efficiency particulate air" ceramic membrane filters as a function of particle size over a wide range of filter thickness and texture (pore size and porosity) and operating conditions (face velocity).
Functional polycarbonates and their self-assemblies as promising non-viral vectors.
Seow, Wei Yang; Yang, Yi Yan
2009-10-01
Polycarbonates are promising biomaterials due to their biocompatibility, degradability and low toxicity. In this study, a series of COOH-functionalized polycarbonates was synthesized via an organocatalytic ring opening polymerization pathway under mild conditions. The polymers displayed a range of molecular weights (M(w): 3.1, 5.5 and 9.7 kDa) and were very narrowly distributed (polydispersity index: 1.07, 1.07 and 1.15 respectively). Aliphatic amines with different chain lengths (triethylenetetramine, tetraethylenepentamine or pentaethylenehexamine) were then conjugated onto the polycarbonate backbone using DIC/NHS chemistry. These amine-functionalized polycarbonates could form nanoparticles upon simple dissolution in water and had CMC values ranging from 22 to 45 mg/L. It was found that a longer amine chain resulted in greater buffering capacity, more positive zeta potential and smaller hydrodynamic size of the polymeric nanoparticles. Results from gel retardation assays indicated that the polymers were able to condense DNA. In-vitro studies further demonstrated that selected amine-functionalized polycarbonates could mediate efficient luciferase expression in HEK293, HepG2 and 4T1 cell lines at levels that were comparable, or even superior, to the polyethylenimine (PEI) standard. Importantly, minimal cytotoxicty was induced in the cells. These functional polycarbonates therefore have the potential to be a useful non-viral vector for gene therapy.
Elliott, D.G.; McKibben, C.L.
1997-01-01
Two versions of the fluorescent antibody technique (FAT) were compared for detection and quantification of Renibacterium salmoninarum in coelomic fluid samples from naturally infected spawning chinook salmon Oncorhynchus tshawytscha. For the membrane filtration-FAT (MF-FAT), trypsin-treated samples were passed through 0.2 ??m polycarbonate filters to concentrate bacteria for direct enumeration by immunofluorescence microscopy. For the smear-FAT (S-FAT), samples were centrifuged at 8800 x g for 10 min and the pelleted material was smeared on slides for immunofluorescence staining Detected prevalences of Renibacterium salmoninarum were 1.8 to 3.4 times higher by the MF-FAT than by the S-FAT: differences were significant at p ??? 0.0002. The S-FAT consistently detected R. salmoninarum only in samples with calculated bacterial concentrations ??? 2.4 x 103 cells ml-1 by MF-FAT testing. Increasing the area examined on a filter or slide from 50 to 100 microscope fields at 1000x magnification resulted in the detection of a maximum of 4% additional positive samples by the MF-FAT and 7% additional positive samples by the S-FAT. In individual samples for which bacterial counts were obtained by both the MF-FAT and the S-FAT, the counts averaged from 47 times (??30 SD) to 175 times (??165 SD) higher by the MF-FAT. Centrifugation of samples at 10000 x g for 10 min resulted in a 4-fold increase in mean bacterial counts by the S-FAT compared with a 10-min centrifugation at 2000 x g, but the highest calculated bacterial concentration obtained by S-FAT testing was more than 6-fold lower than that obtained for the same sample by MF-FAT testing. Because of its greater sensitivity, the MF-FAT is preferable to the S-FAT for use in critical situations requiring the detection of low numbers of R. salmoninarum.
Phelps, T J; Palumbo, A V; Bischoff, B L; Miller, C J; Fagan, L A; McNeilly, M S; Judkins, R R
2008-07-01
Robust filtering techniques capable of efficiently removing particulates and biological agents from water or air suffer from plugging, poor rejuvenation, low permeance, and high backpressure. Operational characteristics of pressure-driven separations are in part controlled by the membrane pore size, charge of particulates, transmembrane pressure and the requirement for sufficient water flux to overcome fouling. With long term use filters decline in permeance due to filter-cake plugging of pores, fouling, or filter deterioration. Though metallic filter tube development at ORNL has focused almost exclusively on gas separations, a small study examined the applicability of these membranes for tangential filtering of aqueous suspensions of bacterial-sized particles. A mixture of fluorescent polystyrene microspheres ranging in size from 0.5 to 6 microm in diameter simulated microorganisms in filtration studies. Compared to a commercial filter, the ORNL 0.6 microm filter averaged approximately 10-fold greater filtration efficiency of the small particles, several-fold greater permeance after considerable use and it returned to approximately 85% of the initial flow upon backflushing versus 30% for the commercial filter. After filtering several liters of the particle-containing suspension, the ORNL composite filter still exhibited greater than 50% of its initial permeance while the commercial filter had decreased to less than 20%. When considering a greater filtration efficiency, greater permeance per unit mass, greater percentage of rejuvenation upon backflushing (up to 3-fold), and likely greater performance with extended use, the ORNL 0.6 microm filters can potentially outperform the commercial filter by factors of 100-1,000 fold.
Department of Defense Enhanced Particulate Matter Surveillance Program (EPMSP)
2008-02-01
on Teflon® membrane, 23,807 on quartz fiber, and several million single particle analyses on Nuclepore® filters. Analytical results were...Nuclepore® filters, the sampling period was two hours, so as to provide lightly loaded filters with dispersed single particles, as required for CCSEM...membrane, 23,807 on quartz fiber, and several million single particle analyses on Nuclepore®. All results, together with summary tables and more than
Brodsky, M H; Schiemann, D A
1976-01-01
Pfizer selective enterococcus (PSE) and KF agars were compared for their recovery of fecal streptococci from sewage effluent on membrane filters. The results showed that PSE agar is highly selective for the enterococci. The tan color resulting from esculin hydrolysis, which was not always visible on the surfaces of the colonies, is not considered a necessary differential characteristic on PSE agar since more than 90% of all colonies recovered on membrane filters were confirmed as fecal streptococci and 86% were confirmed as enterococci. The detection of esculin hydrolysis on membrane filters was not improved by using the new Millipore type HC filter. KF agar recovered significantly greater numbers of organisms but was not as selective, with 83% of the typical colonies being confirmed as fecal streptococci and 54% as enterococci. An attempt to improve the selectivity of KF agar while retaining its inclusiveness by incubation at 45 C was not successful. PMID:818956
Experimental and computational investigation of lateral gauge response in polycarbonate
NASA Astrophysics Data System (ADS)
Eliot, Jim; Harris, Ernst; Hazell, Paul; Appleby-Thomas, Gareth; Winter, Ronald; Wood, David; Owen, Gareth
2011-06-01
Polycarbonate's use in personal armour systems means its high strain-rate response has been extensively studied. Interestingly, embedded lateral manganin stress gauges in polycarbonate have shown gradients behind incident shocks, suggestive of increasing shear strength. However, such gauges need to be embedded in a central (typically) epoxy interlayer - an inherently invasive approach. Recently, research has suggested that in such metal systems interlayer/target impedance may contribute to observed gradients in lateral stress. Here, experimental T-gauge (Vishay Micro-Measurements® type J2M-SS-580SF-025) traces from polycarbonate targets are compared to computational simulations. This work extends previous efforts such that similar impedance exists between the interlayer and matrix (target) interface. Further, experiments and simulations are presented investigating the effects of a ``dry joint'' in polycarbonate, in which no encapsulating medium is employed.
NASA Astrophysics Data System (ADS)
Kihara, Naoto; Odaka, Hidefumi; Kuboyama, Daiki; Onoshima, Daisuke; Ishikawa, Kenji; Baba, Yoshinobu; Hori, Masaru
2018-03-01
Although membrane filters are indispensable in biochemical analysis fields, most methods for through-hole fabrication are complex and inefficient. We developed a simple method of fabricating poly(ethylene terephthalate) (PET) membrane filters with a precise arrangement of through-holes for the isolation of circulating tumor cells (CTCs) based on their size. By photolithography and dry etching, highly packed 380,000 through-holes with a diameter of 7 µm were able to cover a whole area with a diameter of 13 mm. Device fabrication for the size-based capture of rare cells in blood such as CTCs is realized in this study.
A reference protocol for comparing the biocidal properties of gas plasma generating devices
NASA Astrophysics Data System (ADS)
Shaw, A.; Seri, P.; Borghi, C. A.; Shama, G.; Iza, F.
2015-12-01
Growing interest in the use of non-thermal, atmospheric pressure gas plasmas for decontamination purposes has resulted in a multiplicity of plasma-generating devices. There is currently no universally approved method of comparing the biocidal performance of such devices and in the work described here spores of the Gram positive bacterium Bacillus subtilis (ATCC 6633) are proposed as a suitable reference biological agent. In order to achieve consistency in the form in which the biological agent in question is presented to the plasma, a polycarbonate membrane loaded with a monolayer of spores is proposed. The advantages of the proposed protocol are evaluated by comparing inactivation tests in which an alternative microorganism (methicillin resistant Staphylococcus aureus—MRSA) and the widely-used sample preparation technique of directly pipetting cell suspensions onto membranes are employed. In all cases, inactivation tests with either UV irradiation or plasma exposure were more reproducible when the proposed protocol was followed.
Impact of culture media and sampling methods on Staphylococcus aureus aerosols.
Chang, C-W; Wang, L-J
2015-10-01
Staphylococcus aureus has been detected indoors and is associated with human infection. Reliable quantification of S. aureus using a sampling technique followed by culture assay helps in assessing the risks of human exposure. The efficiency of five culture media and eight sampling methods in recovering S. aureus aerosols were evaluated. Methods to extract cells from filters were also studied. Tryptic soy agar (TSA) presented greater bacterial recovery than mannitol salt agar (MSA), CHROMagar staph aureus, Chapman stone medium, and Baird-Park agarose (P < 0.05). Moreover, 93 ± 2%-95 ± 2% and 42 ± 1%-49 ± 2% of S. aureus were, respectively, recovered by a 15-min heating of gelatin filters and 2-min vortex of polycarbonate (PC) filters. Evaluation of two filtration (IOM with gelatin filter and cassette with PC filter), two impaction (Andersen 1-STG loaded with TSA and MSA) and four impingement methods [AGI-30 and BioSampler filled with Tween mixture (TM) and phosphate-buffered saline (PBS)] revealed the BioSampler/TM performed best over 30 and 60 min of sampling (P < 0.05), while low recovery efficiencies were associated with the IOM/gelatin, cassette/PC, and AGI-30/PBS combinations (P < 0.05). In addition to BioSampler/TM, collecting S. aureus onto TSA from the Andersen 1-STG is also recommended, as it is the second best method at the 60-min sampling (P < 0.05). © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Field evaluation of personal sampling methods for multiple bioaerosols.
Wang, Chi-Hsun; Chen, Bean T; Han, Bor-Cheng; Liu, Andrew Chi-Yeu; Hung, Po-Chen; Chen, Chih-Yong; Chao, Hsing Jasmine
2015-01-01
Ambient bioaerosols are ubiquitous in the daily environment and can affect health in various ways. However, few studies have been conducted to comprehensively evaluate personal bioaerosol exposure in occupational and indoor environments because of the complex composition of bioaerosols and the lack of standardized sampling/analysis methods. We conducted a study to determine the most efficient collection/analysis method for the personal exposure assessment of multiple bioaerosols. The sampling efficiencies of three filters and four samplers were compared. According to our results, polycarbonate (PC) filters had the highest relative efficiency, particularly for bacteria. Side-by-side sampling was conducted to evaluate the three filter samplers (with PC filters) and the NIOSH Personal Bioaerosol Cyclone Sampler. According to the results, the Button Aerosol Sampler and the IOM Inhalable Dust Sampler had the highest relative efficiencies for fungi and bacteria, followed by the NIOSH sampler. Personal sampling was performed in a pig farm to assess occupational bioaerosol exposure and to evaluate the sampling/analysis methods. The Button and IOM samplers yielded a similar performance for personal bioaerosol sampling at the pig farm. However, the Button sampler is more likely to be clogged at high airborne dust concentrations because of its higher flow rate (4 L/min). Therefore, the IOM sampler is a more appropriate choice for performing personal sampling in environments with high dust levels. In summary, the Button and IOM samplers with PC filters are efficient sampling/analysis methods for the personal exposure assessment of multiple bioaerosols.
Burkhardt, Mark R.; Brenton, Ronald W.; Kammer, James A.; Jha, Virenda K.; O'Mara-Lopez, Peggy G.; Woodworth, Mark T.
1999-01-01
Precision and accuracy are reported for the first time for the analysis of nonpurgeable suspended organic carbon by silver membrane filtration followed by wet chemical oxidation. A water sample is pressure filtered through a 0.45‐μm‐pore‐size, 47‐mm‐diameter silver membrane filter. The silver membrane filter then is cut into ribbons and placed in a flame‐sealable glass ampule. The organic material trapped on the membrane filter strips is acidified, purged with oxygen to remove inorganic carbonates and volatile organic compounds, and oxidized to carbon dioxide (CO2) using phosphoric acid and potassium persulfate in the sealed glass ampule. The resulting CO2 is measured by a nondispersive infrared CO2 detector. The amount of CO2 is proportional to the concentration of chemically oxidizable nonpurgeable organic carbon in the environmental water sample. The quantitation and method detection limit for routine analysis is 0.2 mg/L. The average percent recovery in five representative matrices was 97 ± 11%. The errors associated with sampling and sample preparation of nonpurgeable suspended organic carbon are also described.
Dominique, Marie; Mitrofanov, A V; Hochedez, J-F; Apel, P Yu; Schühle, U; Pudonin, F A; Orelovich, O L; Zuev, S Yu; Bolsée, D; Hermans, C; BenMoussa, A
2009-02-10
We describe the fabrication and performance of diffractive filters designed for space-based x-ray and EUV solar observations. Unlike traditional thin film filters, diffractive filters can be made to have a high resistance against the destructive mechanical and acoustic loads of a satellite launch. The filters studied are made of plastic track-etched membranes that are metal-coated on one side only. They have all-through open cylindrical pores with diameters as small as 500 nm, limiting their transmittance to very short wavelengths. The spectral transmittance of various diffractive filters with different pore parameters was measured from the soft x-ray to the near IR range (namely, from 1-1100 nm).
Kim, Taegeon; Canlier, Ali; Kim, Geun Hong; Choi, Jaeho; Park, Minkyu; Han, Seung Min
2013-02-01
In this work, a modified polyol synthesis by adding KBr and by replacing the AgCl with NaCl seed was used to obtain high quality silver nanowires with long aspect ratios with an average length of 13.5 μm in length and 62.5 nm in diameter. The Ag nanowires suspended in methanol solution after removing any unwanted particles using a glass filter system were then deposited on a flexible polycarbonate substrate using an electrostatic spray system. Transmittance of 92.1% at wavelength of 550 nm with sheet resistance of 20 Ω/sq and haze of 4.9% were measured for the electrostatic sprayed Ag nanowire transparent electrode.
MEMBRANE FILTER PROCEDURE FOR ENUMERATING THE COMPONENT GENERA OF THE COLIFORM GROUP IN SEAWATER
A facile, quantitative, membrane filter procedure (mC) for defining the distribution of coliform populations in seawater according to the component genera was developed. The procedure, which utilizes a series of in situ substrate tests to obviate the picking of colonies for ident...
Organic colloids and their influence on low-pressure membrane filtration.
Laabs, C; Amy, G; Jekel, M
2004-01-01
Wastewater treatment by low-pressure membrane filtration (MF and UF) is affected to a large extent by macromolecules and colloids. In order to investigate the influence of organic colloids on the membrane filtration process, colloids were isolated from a wastewater treatment plant effluent using a rotary-evaporation pre-concentration step followed by dialysis. Stirred cell tests were carried out using redissolved colloids, with and without additional glass fiber filtration. After constant pressure membrane filtration of 190 L/m2, the initial flux had declined by 50% for colloids > 6-8 kD (glass fiber filtered) with a hydrophilic MF membrane and for colloids > 12-14 kD (glass fiber filtered) with a hydrophobic MF membrane. For the non-filtered colloidal solutions, the flux decline was even steeper with the flux being below 10% of the initial flux after 190 L/m2 were passed through the membranes. As with larger particles, colloids form a filtration cake layer on top of the membrane surface when used as isolates without prior filtration. This filtration cake is easily removed during backwashing. However, polysaccharides as a macromolecular component of the colloid isolate cause severe fouling by the formation of a gel layer on the membrane surface that is difficult to remove completely.
Ramesh, V; Biswal, Manoranjan; Mohanty, Smita; Nayak, Sanjay K
2014-05-01
This study is focused on the recovery and recycling of plastics waste, primarily polycarbonate, poly(acrylonitrile-butadiene-styrene) and high impact polystyrene, from end-of-life waste electrical and electronic equipments. Recycling of used polycarbonate, acrylonitrile-butadiene-styrene, polycarbonate/acrylonitrile-butadiene-styrene and acrylonitrile-butadiene-styrene/high impact polystrene material was carried out using material recycling through a melt blending process. An optimized blend composition was formulated to achieve desired properties from different plastics present in the waste electrical and electronic equipments. The toughness of blended plastics was improved with the addition of 10 wt% of virgin polycarbonate and impact modifier (ethylene-acrylic ester-glycidyl methacrylate). The mechanical, thermal, dynamic-mechanical and morphological properties of recycled blend were investigated. Improved properties of blended plastics indicate better miscibility in the presence of a compatibilizer suitable for high-end application.
Helmet of a laminate construction of polycarbonate and polysulfone polymeric material
NASA Technical Reports Server (NTRS)
Kosmo, Joseph J. (Inventor); Dawn, Frederic S. (Inventor)
1991-01-01
An article of laminate construction is disclosed which is comprised of an underlayer of polycarbonate polymer material to which is applied a chemically resistant outer layer of polysulfone. The layers which are joined by compression-heat molding, are molded to form the shape of a body protective shell such as a space helmet comprising a shell of polycarbonate, polysulfone laminate construction attached at its open end to a sealing ring adapted for connection to a space suit. The front portion of the shell provides a transparent visor for the helmet. An outer visor of polycarbonate polysulfone laminate construction is pivotally mounted to the sealing ring for covering the transparent visor portion of the shell during extravehicular activities. The polycarbonate under layer of the outer visor is coated on its inner surface with a vacuum deposit of gold to provide additional thermal radiation resistance.
Ferrari, Belinda C.; Binnerup, Svend J.; Gillings, Michael
2005-01-01
Traditional microbiological methods of cultivation recover less than 1% of the total bacterial species, and the culturable portion of bacteria is not representative of the total phylogenetic diversity. Classical cultivation strategies are now known to supply excessive nutrients to a system and therefore select for fast-growing bacteria that are capable of colony or biofilm formation. New approaches to the cultivation of bacteria which rely on growth in dilute nutrient media or simulated environments are beginning to address this problem of selection. Here we describe a novel microcultivation method for soil bacteria that mimics natural conditions. Our soil slurry membrane system combines a polycarbonate membrane as a growth support and soil extract as the substrate. The result is abundant growth of uncharacterized bacteria as microcolonies. By combining microcultivation with fluorescent in situ hybridization, previously “unculturable” organisms belonging to cultivated and noncultivated divisions, including candidate division TM7, can be identified by fluorescence microscopy. Successful growth of soil bacteria as microcolonies confirmed that the missing culturable majority may have a growth strategy that is not observed when traditional cultivation indicators are used. PMID:16332866
Dereli, Recep Kaan; Grelot, Aurelie; Heffernan, Barry; van der Zee, Frank P; van Lier, Jules B
2014-08-01
Long-term experiments were conducted to assess the impact of changing the solids retention time (SRT) on sludge filterability in anaerobic membrane bioreactors (AnMBRs), treating corn-based bioethanol thin stillage. Well established parameters, such as capillary suction time (CST) and specific resistance to filtration (SRF), developed for sludge dewatering, were used to evaluate the SRT effect on sludge filterability. Our results clearly demonstrated that SRT is one of the most important factors influencing sludge filterability in AnMBRs. SRT effects the accumulation of fine particles and solutes, which were found to affect attainable flux and fouling, in reactor broth. A better filterability was observed at a SRT of 20 days compared to elevated SRTs, i.e. 50 days. A clear correlation between sludge filtration characteristics and membrane filtration resistance could not be established especially at short SRTs, whereas many parameters such as total suspended solids (TSS), CST, soluble microbial products (SMP) and supernatant filterability were found to be mutually correlated. Net membrane fluxes between 9 and 13 L m(-2) h(-1) were obtained at 0.5 m s(-1) cross-flow velocity and the long term fouling was controlled by using frequent filtration and backwash cycles. Copyright © 2014 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Wang, Lanlan; Liu, Hongzhong; Jiang, Weitao; Gao, Wei; Chen, Bangdao; Li, Xin; Ding, Yucheng; An, Ningli
2014-12-01
A freestanding multilayer ultrathin nano-membrane (FUN-membrane) with a micro-ring array (MRA) is successfully fabricated through the controllable film deposition. Each micro-ring of FUN-membrane is 3 μm in diameter, 2 μm in height and sub-100 nm in sidewall thickness, demonstrating an ultrahigh sidewall aspect ratio of 20:1. In our strategy, a silica layer (200 nm in thickness), a chromium transition layer (5 nm-thick) and a gold layer (40 nm-thick), were in sequence deposited on patterned photoresist. After removal of the photoresist by lift-off process, a FUN-membrane with MRA was peeled off from the substrate, where the gold layer acted as a protecting layer to prevent the MRA from fracture. The FUN-membrane was then transferred to a flexible polycarbonate (PC) sheet coated with indium tin oxide (ITO) layer, which was then used as a flexible and lightweight cathode. Remarkably, the field emission effect of the fabricated FUN-membrane cathode performs a high field-enhancement factor of 1.2 × 104 and a low turn-on voltage of 2 V/μm, indicating the advantages of the sharp metal edge of MRA. Due to the rational design and material versatility, the FUN-membrane thus could be transferred to either rigid or flexible substrate, even curved surface, such as the skin of bio-robot's arm or leg. Additionally, the FUN-membrane composed of MRA with extremely high aspect ratio of insulator-metal sidewall, also provides potential applications in optical devices, lightweight and flexible display devices, and electronic eye imagers.
Thermo-inelastic Response of Polymeric Solids
2014-08-11
phenomena. Polymethylmethacrylate (PMMA) and Polycarbonate (PC) are used in this study. Results indicate that the stress on the wall was lowest...explicit scheme for the time evaluation and in order to capture the wave propagation phenomena. Polymethylmethacrylate (PMMA) and Polycarbonate (PC) are...polyurea(PU), polycarbonate(PC), polymethylmethacrylate (PMMA) etc. for the ballistic protection. For example, it can be seen from the figures 1 through 3
NASA Astrophysics Data System (ADS)
Song, Jing; Jańczewski, Dominik; Guo, Yuanyuan; Xu, Jianwei; Vancso, G. Julius
2013-11-01
Redox responsive nanotubes were fabricated by the template assisted layer-by-layer (LbL) assembly method and employed as platforms for molecular payload release. Positively and negatively charged organometallic poly(ferrocenylsilane)s (PFS) were used to construct the nanotubes, in combination with other polyions. During fabrication, multilayers of these polyions were deposited onto the inner pores of template porous membranes, followed by subsequent removal of the template. Anodized porous alumina and track-etched polycarbonate membranes were used as templates. The morphology, electrochemistry, composition and other properties of the obtained tubular structure were characterized by fluorescence microscopy, scanning (SEM) and transmission electron microscopy (TEM) and energy-dispersive X-ray (EDX) spectroscopy. Composite nanotubes, consisting of poly(acrylic acid) anions with PFS+ and nanoparticles including fluorophore labelled dextran and decorated quantum dots, with PFS polyelectrolytes were also fabricated, broadening the scope of the structures. Cyclic voltammograms of PFS containing nanotubes showed similar redox responsive behaviour to thin LbL assembled films. Redox triggered release of labelled macromolecules from these tubular structures demonstrated application potential in controlled molecular delivery.Redox responsive nanotubes were fabricated by the template assisted layer-by-layer (LbL) assembly method and employed as platforms for molecular payload release. Positively and negatively charged organometallic poly(ferrocenylsilane)s (PFS) were used to construct the nanotubes, in combination with other polyions. During fabrication, multilayers of these polyions were deposited onto the inner pores of template porous membranes, followed by subsequent removal of the template. Anodized porous alumina and track-etched polycarbonate membranes were used as templates. The morphology, electrochemistry, composition and other properties of the obtained tubular structure were characterized by fluorescence microscopy, scanning (SEM) and transmission electron microscopy (TEM) and energy-dispersive X-ray (EDX) spectroscopy. Composite nanotubes, consisting of poly(acrylic acid) anions with PFS+ and nanoparticles including fluorophore labelled dextran and decorated quantum dots, with PFS polyelectrolytes were also fabricated, broadening the scope of the structures. Cyclic voltammograms of PFS containing nanotubes showed similar redox responsive behaviour to thin LbL assembled films. Redox triggered release of labelled macromolecules from these tubular structures demonstrated application potential in controlled molecular delivery. Electronic supplementary information (ESI) available: Nanotube wall thickness determination protocol. See DOI: 10.1039/c3nr03927g
Coleman, Jessica G; Lotufo, Guilherme R; Kennedy, Alan J; Poda, Aimee R; Rushing, Todd S; Ruiz, Carlos E; Bridges, Todd S
2014-07-01
In benthic sediment bioassays, determining the relative contribution to exposure by contaminants in overlying water, porewater, and sediment particles is technically challenging. The purpose of the present study was to assess the potential for membranes to be utilized as a mechanism to allow freely dissolved hydrophobic organic contaminants into a pathway isolation exposure chamber (PIC) while excluding all sediment particles and dissolved organic carbon (DOC). This investigation was conducted in support of a larger effort to assess contaminant exposure pathways to benthos. While multiple passive samplers exist for estimating concentrations of contaminants in porewater such as those using solid-phase micro extraction (SPME) and polyoxymethylene (POM), techniques to effectively isolate whole organism exposure to porewater within a sediment system are not available. We tested the use of four membranes of different pore sizes (0.1-1.2μm) including nylon, polycarbonate, polyethylsulfone, and polytetrafluoroethylene with a hydrophilic coating. Exposures included both diffusion of radiolabeled and non-labeled contaminants across membranes from aqueous, sediment slurry, and whole sediment sources to assess and evaluate the best candidate membrane. Data generated from the present study was utilized to select the most suitable membrane for use in the larger bioavailability project which sought to assess the relevance of functional ecology in bioavailability of contaminated sediments at remediation sites. The polytetrafluoroethylene membrane was selected for use in the PIC, although exclusion of dissolved organic carbon was not achieved. Published by Elsevier Ltd.
Comparing the biocidal properties of non-thermal plasma sources by reference protocol
NASA Astrophysics Data System (ADS)
Khun, Josef; Jirešová, Jana; Kujalová, Lucie; Hozák, Pavel; Scholtz, Vladimír
2017-10-01
The previously proposed reference protocol enabling easy comparison of biocidal properties of different non-thermal plasma sources has been followed and discussed. For inactivation tests the reference protocol has used spores of Gram positive bacterium Bacillus subtilis (ATCC 6633) deposited on a polycarbonate membrane as reference sample. In this work, biocidal properties of a negative glow corona, positive streamer corona, positive transient spark and cometary discharges are being compared in both open air and closed apparatus. Despite the total number of bacteria surviving 1 h exposure has decreased by up to 7 orders in closed apparatus, in open one, only weak inhibition bactericidal effect has been observed.
Burnout current density of bismuth nanowires
NASA Astrophysics Data System (ADS)
Cornelius, T. W.; Picht, O.; Müller, S.; Neumann, R.; Völklein, F.; Karim, S.; Duan, J. L.
2008-05-01
Single bismuth nanowires with diameters ranging from 100nmto1μm were electrochemically deposited in ion track-etched single-pore polycarbonate membranes. The maximum current density the wires are able to carry was investigated by ramping up the current until failure occurred. It increases by three to four orders of magnitude for nanowires embedded in the template compared to bulk bismuth and rises with diminishing diameter. Simulations show that the wires are heated up electrically to the melting temperature. Since the surface-to-volume ratio rises with diminishing diameter, thinner wires dissipate the heat more efficiently to the surrounding polymer matrix and, thus, can tolerate larger current densities.
Slimani, Sami; Robyns, Audrey; Jarraud, Sophie; Molmeret, Maëlle; Dusserre, Eric; Mazure, Céline; Facon, Jean Pierre; Lina, Gérard; Etienne, Jerome; Ginevra, Christophe
2012-02-01
A PMA (propidium monoazide) pretreatment protocol, in which PMA is applied directly to membrane filters, was developed for the PCR-based quantification (PMA-qPCR) of viable Legionella pneumophila. Using this method, the amplification of DNA from membrane-damaged L. pneumophila was strongly inhibited for samples containing a small number of dead bacteria. Copyright © 2011 Elsevier B.V. All rights reserved.
Methods for detecting total coliform bacteria in drinking water were compared using 1483 different drinking water samples from 15 small community water systems in Vermont and New Hampshire. The methods included the membrane filter (MF) technique, a ten tube fermentation tube tech...
Tsou, Pei-Hsiang; Sreenivasappa, Harini; Hong, Sungmin; Yasuike, Masayuki; Miyamoto, Hiroshi; Nakano, Keiyo; Misawa, Takeyuki; Kameoka, Jun
2010-09-15
We have developed a filter-chip and optical detection system for rapid antibiotic efficacy screening. The filter-chip consisted of a 1-mL reservoir and an anodic aluminum oxide (AAO) nanoporous membrane. Sample solution with liquid growth media, bacteria, and antibiotics was incubated in the reservoir for a specific period of time. The number of live bacteria on the surface of membrane was counted after the incubation with antibiotics and filtration. Using this biosensing system, we have demonstrated a 1-h antibiotic screening for patients' clinical samples, significantly faster than the conventional antibiotic susceptibility tests that typically take more than 24h. This rapid screening nature makes the filter-chip and detection system ideal for tailoring antibiotic treatment to individual patients by reducing the microbial antibiotic resistance, and improving the survival rate for patients suffering from postoperative infections. Published by Elsevier B.V.
NASA Astrophysics Data System (ADS)
Pierce, A.; Gustin, M. S.; Huang, J.; Heidecorn, K.
2014-12-01
Three active mercury (Hg) measurement methods were operated side by side at an urban site (University of Nevada, Reno College of Agriculture Greenhouse facility, elev. 1370 m) in Reno, and at a high elevation site (Peavine Peak, elev. 2515 m) adjacent to Reno from December 2013 to October 2014. A model 602 BetaPlus Teledyne Advanced Pollution Instrumentation (TAPI, San Diego, CA USA) particulate measurement system was used to collect particulate matter on a 47 mm diameter cation exchange membrane (CEM, PN# MSTGS3R Mustang S, Pall Corp. Port Washington, NY) at a rate of 16.7 lpm for 24 hours to four days. Particulate concentrations were calculated using beta attenuation across the filters (non-destructive to filter material); the CEM filters were then analyzed for total Hg on a Tekran Total Hg Analysis system (model 2600, Tekran Instruments Corp. Knoxville, TN, USA). Concurrently, samples were collected on an active Hg membrane system. The active Hg membrane system consisted of 3 CEM filters sampling at a rate of 1 lpm for one to two weeks. CEM filters were then analyzed on the Tekran 2600. A Tekran speciation unit (model 1130, 1135, 2537) was also in operation and ambient air samples were analyzed for gaseous elemental Hg (GEM), gaseous oxidized Hg (GOM), and particulate bound Hg (PBM). Both the 602 BetaPlus system and the active Hg membrane system should collect RM on the CEM filters. The active Hg membrane system most likely captures mainly GOM based on previous tests with the Teflon inlet setup that indicated there was high static electricity effective in removing particulate matter. Flow rate and length of measurement (24 hours vs. four days) affected the Hg concentrations on the 602 BetaPlus system. Based on these measurements we hypothesize that, due to the high flow rate, and therefore short retention time, the 602 BetaPlus only captured PBM. It is also possible that there was loss of Hg to inlet walls due to the longer inlet on the 602 BetaPlus system compared to the active Hg membrane system.
Process for making ceramic hot gas filter
Connolly, Elizabeth Sokolinski; Forsythe, George Daniel; Domanski, Daniel Matthew; Chambers, Jeffrey Allen; Rajendran, Govindasamy Paramasivam
2001-01-01
A ceramic hot-gas candle filter having a porous support of filament-wound oxide ceramic yarn at least partially surrounded by a porous refractory oxide ceramic matrix, and a membrane layer on at least one surface thereof. The membrane layer may be on the outer surface, the inner surface, or both the outer and inner surface of the porous support. The membrane layer may be formed of an ordered arrangement of circularly wound, continuous filament oxide ceramic yarn, a ceramic filler material which is less permeable than the filament-wound support structure, or some combination of continuous filament and filler material. A particularly effective membrane layer features circularly wound filament with gaps intentionally placed between adjacent windings, and a filler material of ceramic particulates uniformly distributed throughout the gap region. The filter can withstand thermal cycling during backpulse cleaning and is resistant to chemical degradation at high temperatures.
Connolly, Elizabeth Sokolinski; Forsythe, George Daniel; Domanski, Daniel Matthew; Chambers, Jeffrey Allen; Rajendran, Govindasamy Paramasivam
1999-01-01
A ceramic hot-gas candle filter having a porous support of filament-wound oxide ceramic yarn at least partially surrounded by a porous refractory oxide ceramic matrix, and a membrane layer on at least one surface thereof. The membrane layer may be on the outer surface, the inner surface, or both the outer and inner surface of the porous support. The membrane layer may be formed of an ordered arrangement of circularly wound, continuous filament oxide ceramic yarn, a ceramic filler material which is less permeable than the filament-wound support structure, or some combination of continuous filament and filler material. A particularly effective membrane layer features circularly wound filament with gaps intentionally placed between adjacent windings, and a filler material of ceramic particulates uniformly distributed throughout the gap region. The filter can withstand thermal cycling during backpulse cleaning and is resistant to chemical degradation at high temperatures.
The effect of membrane filtration on dissolved trace element concentrations
Horowitz, A.J.; Lum, K.R.; Garbarino, J.R.; Hall, G.E.M.; Lemieux, C.; Demas, C.R.
1996-01-01
The almost universally accepted operational definition for dissolved constituents is based on processing whole-water samples through a 0.45-??m membrane filter. Results from field and laboratory experiments indicate that a number of factors associated with filtration, other than just pore size (e.g., diameter, manufacturer, volume of sample processed, amount of suspended sediment in the sample), can produce substantial variations in the 'dissolved' concentrations of such elements as Fe, Al, Cu, Zn, Pb, Co, and Ni. These variations result from the inclusion/exclusion of colloidally- associated trace elements. Thus, 'dissolved' concentrations quantitated by analyzing filtrates generated by processing whole-water through similar pore- sized membrane filters may not be equal/comparable. As such, simple filtration through a 0.45-??m membrane filter may no longer represent an acceptable operational definition for dissolved chemical constituents. This conclusion may have important implications for environmental studies and regulatory agencies.
Connolly, E.S.; Forsythe, G.D.; Domanski, D.M.; Chambers, J.A.; Rajendran, G.P.
1999-05-11
A ceramic hot-gas candle filter is described having a porous support of filament-wound oxide ceramic yarn at least partially surrounded by a porous refractory oxide ceramic matrix, and a membrane layer on at least one surface thereof. The membrane layer may be on the outer surface, the inner surface, or both the outer and inner surface of the porous support. The membrane layer may be formed of an ordered arrangement of circularly wound, continuous filament oxide ceramic yarn, a ceramic filler material which is less permeable than the filament-wound support structure, or some combination of continuous filament and filler material. A particularly effective membrane layer features circularly wound filament with gaps intentionally placed between adjacent windings, and a filler material of ceramic particulates uniformly distributed throughout the gap region. The filter can withstand thermal cycling during back pulse cleaning and is resistant to chemical degradation at high temperatures.
Mullett, Mark; Fornarelli, Roberta; Ralph, David
2014-01-01
Two nanofiltration membranes, a Dow NF 270 polyamide thin film and a TriSep TS 80 polyamide thin film, were investigated for their retention of ionic species when filtering mine influenced water streams at a range of acidic pH values. The functional iso-electric point of the membranes, characterized by changes in retention over a small pH range, were examined by filtering solutions of sodium sulphate. Both membranes showed changes in retention at pH 3, suggesting a zero net charge on the membranes at this pH. Copper mine drainage and synthetic solutions of mine influenced water were filtered using the same membranes. These solutions were characterized by pH values within 2 and 5, thus crossing the iso-electric point of both membranes. Retention of cations was maximized when the feed solution pH was less than the iso-electric point of the membrane. In these conditions, the membrane has a net positive charge, reducing the transmission rate of cations. From the recoveries of a range of cations, the suitability of nanofiltration was discussed relative to the compliance with mine water discharge criteria and the recovery of valuable commodity metals. The nanofiltration process was demonstrated to offer advantages in metal recovery from mine waste streams, concomitantly enabling discharge criteria for the filtrate disposal to be met. PMID:24957170
Infrared welding process on composite: Effect of interdiffusion at the welding interface
NASA Astrophysics Data System (ADS)
Asseko, André Chateau Akué; Lafranche, Éric; Cosson, Benoît; Schmidt, Fabrice; Le Maoult, Yannick
2016-10-01
In this study, the effects of the welding temperature field developed during the infrared assembly process on the joining properties of glass fibre reinforced polycarbonate/ unreinforced polycarbonate with carbon black were investigated. The temperature field and the contact time govern together the quality of the adhesion at the welding interface. The effect of the semi-transparent glass fibre reinforced polycarbonate composite / unreinforced polycarbonate composite with carbon black interface was quantified in term of quadratic distance of diffusion or diffusion depth through the welding interface. The microstructural characterizations were investigated in order to inspect the welding zones quality and to observe their failure modes. The diffusion theory has then been applied to calculate the variation of the quadratic distance of diffusion versus time at different locations. The complete self-diffusion is supposed occurring only at temperature above the polycarbonate glass transition temperature (140°C) and with a quadratic distance of diffusion superior to the mean square end-to-end distance.
Yilbas, Bekir Sami; Ali, Haider; Al-Aqeeli, Naseer; Khaled, Mazen M; Said, Syed; Abu-Dheir, Numan; Merah, Necar; Youcef-Toumi, Kamal; Varanasi, Kripa K
2016-04-14
Owing to recent climate changes, dust storms are increasingly common, particularly in the Middle East region. Dust accumulation and subsequent mud formation on solid surfaces in humid environments typically have adverse effects on surface properties such as optical transmittance, surface texture, and microhardness. This is usually because the mud, which contains alkaline and ionic species, adheres strongly to the surface, often through chemical bonds, and is therefore difficult to remove. In this study, environmental dust and the after-effects of mud formed on a polycarbonate sheet, which is commonly used as a protective glass in photovoltaic cells. Ionic compounds (OH(-)) are shown to significantly affect the optical, mechanical, and textural characteristics of the polycarbonate surface, and to increase the adhesion work required to remove the dry mud from the polycarbonate surface upon drying. Such ability to modify characteristics of the polycarbonate surface could address the dust/mud-related limitations of superhydrophobic surfaces.
Yilbas, Bekir Sami.; Ali, Haider; Al-Aqeeli, Naseer; Khaled, Mazen M.; Said, Syed; Abu-Dheir, Numan; Merah, Necar; Youcef-Toumi, Kamal; Varanasi, Kripa K.
2016-01-01
Owing to recent climate changes, dust storms are increasingly common, particularly in the Middle East region. Dust accumulation and subsequent mud formation on solid surfaces in humid environments typically have adverse effects on surface properties such as optical transmittance, surface texture, and microhardness. This is usually because the mud, which contains alkaline and ionic species, adheres strongly to the surface, often through chemical bonds, and is therefore difficult to remove. In this study, environmental dust and the after-effects of mud formed on a polycarbonate sheet, which is commonly used as a protective glass in photovoltaic cells. Ionic compounds (OH−) are shown to significantly affect the optical, mechanical, and textural characteristics of the polycarbonate surface, and to increase the adhesion work required to remove the dry mud from the polycarbonate surface upon drying. Such ability to modify characteristics of the polycarbonate surface could address the dust/mud-related limitations of superhydrophobic surfaces. PMID:27076199
Three-Dimensional Printing of Bisphenol A-Free Polycarbonates.
Zhu, Wei; Pyo, Sang-Hyun; Wang, Pengrui; You, Shangting; Yu, Claire; Alido, Jeffrey; Liu, Justin; Leong, Yew; Chen, Shaochen
2018-02-14
Polycarbonates are widely used in food packages, drink bottles, and various healthcare products such as dental sealants and tooth coatings. However, bisphenol A (BPA) and phosgene used in the production of commercial polycarbonates pose major concerns to public health safety. Here, we report a green pathway to prepare BPA-free polycarbonates (BFPs) by thermal ring-opening polymerization and photopolymerization. Polycarbonates prepared from two cyclic carbonates in different mole ratios demonstrated tunable mechanical stiffness, excellent thermal stability, and high optical transparency. Three-dimensional (3D) printing of the new BFPs was demonstrated using a two-photon laser direct writing system and a rapid 3D optical projection printer to produce structures possessing complex high-resolution geometries. Seeded C3H10T1/2 cells also showed over 95% viability with potential applications in biological studies. By combining biocompatible BFPs with 3D printing, novel safe and high-performance biomedical devices and healthcare products could be developed with broad long-term benefits to society.
Pollastro, R.M.
1982-01-01
Extremely well-oriented clay mineral mounts for X-ray diffraction analysis can be prepared quickly and without introducing segregation using the filter-membrane peel technique. Mounting problems encountered with smectite-rich samples can be resolved by using minimal sample and partial air-drying of the clay film before transfer to a glass slide. Samples containing small quantities of clay can produce useful oriented specimens if Teflon masks having more restrictive areas are inserted above the membrane filter during clay deposition. War]page and thermal shock of glass slides can be controlled by using a flat, porous, ceramic plate as a holding surface during heat treatments.
Le, Hoa H.; Carlson, Emily M.; Chua, Jason P.; Belcher, Scott M.
2008-01-01
The impact of endocrine disrupting chemical (EDC) exposure on human health is receiving increasingly focused attention. The prototypical EDC bisphenol A (BPA) is an estrogenic high-production chemical used primarily as a monomer for production of polycarbonate and epoxy resins. It is now well established that there is ubiquitous human exposure to BPA. In the general population exposure to BPA occurs mainly by consumption of contaminated foods and beverages that have contacted epoxy resins or polycarbonate plastics. To test the hypothesis that bioactive BPA was released from polycarbonate bottles used for consumption of water and other beverages, we evaluated whether BPA migrated into water stored in new or used high-quality polycarbonate bottles used by consumers. Using a sensitive and quantitative competitive enzyme-linked immunosorbent assay, BPA was found to migrate from polycarbonate water bottles at rates ranging from 0.20 to 0.79 ng per hour. At room temperature the migration of BPA was independent of whether or not the bottle had been previously used. Exposure to boiling water (100°C) increased the rate of BPA migration by up to 55-fold. The estrogenic bioactivity of the BPA-like immunoreactivity released into the water samples was confirmed using an in vitro assay of rapid estrogen-signaling and neurotoxicity in developing cerebellar neurons. The amounts of BPA found to migrate from polycarbonate drinking bottles should be considered as a contributing source to the total “EDC-burden” to which some individuals are exposed. PMID:18155859
Visualization of flow during cleaning process on a liquid nanofibrous filter
NASA Astrophysics Data System (ADS)
Bílek, P.
2017-10-01
This paper deals with visualization of flow during cleaning process on a nanofibrous filter. Cleaning of a filter is very important part of the filtration process which extends lifetime of the filter and improve filtration properties. Cleaning is carried out on flat-sheet filters, where particles are deposited on the filter surface and form a filtration cake. The cleaning process dislodges the deposited filtration cake, which is loose from the membrane surface to the retentate flow. The blocked pores in the filter are opened again and hydrodynamic properties are restored. The presented optical method enables to see flow behaviour in a thin laser sheet on the inlet side of a tested filter during the cleaning process. The local concentration of solid particles is possible to estimate and achieve new information about the cleaning process. In the article is described the cleaning process on nanofibrous membranes for waste water treatment. The hydrodynamic data were compared to the images of the cleaning process.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dodson, R.F.; Williams, M.G. Jr.; Corn, C.J.
Ferruginous bodies (FB) in sputa are recognized as an indicator of past exposure to asbestos. However, a great variability exists in FB production, even in individuals with a history of occupational exposure. A further complication in interpreting the presence of FBs in sputa is that all individuals in modern society are exposed to asbestos and, in lung tissue studies, have been shown to harbor appreciable numbers of asbestos fibers. Thus, some of these individuals should occasionally produce FBs in their sputa. The present study was undertaken to determine if uncoated asbestos fiber content could be used to better discriminate occupationallymore » exposed individuals from the general population. Randomly selected sputum samples from 12 former workers in an amosite asbestos plant and 12 controls were studied. The samples were prepared for the study by digesting the sputa in sodium hypochlorite. The digests were filtered through 0.2-microns polycarbonate filters for collection of particulates. The filters were screened for FBs by light microscopy at 200 X, and the presence or absence of uncoated asbestos fibers was determined at 5000 X in an AMRAY 1000A scanning electron microscope. The use of electron microscopy revealed the presence of commercial amphiboles in the sputa of the occupationally exposed individuals and enabled a differentiation of these samples from those of the general population.« less
Polo, Andrea; Foladori, Paola; Ponti, Benedetta; Bettinetti, Roberta; Gambino, Michela; Villa, Federica; Cappitelli, Francesca
2014-05-28
This study provides data to define an efficient biocide-free strategy based on zosteric acid to counteract biofilm formation on the membranes of submerged bioreactor system plants. 16S rRNA gene phylogenetic analysis showed that gammaproteobacteria was the prevalent taxa on fouled membranes of an Italian wastewater plant. Pseudomonas was the prevalent genus among the cultivable membrane-fouler bacteria and Pseudomonas putida was selected as the target microorganism to test the efficacy of the antifoulant. Zosteric acid was not a source of carbon and energy for P. putida cells and, at 200 mg/L, it caused a reduction of bacterial coverage by 80%. Biofilm experiments confirmed the compound caused a significant decrease in biomass (-97%) and thickness (-50%), and it induced a migration activity of the peritrichous flagellated P. putida over the polycarbonate surface not amenable to a biofilm phenotype. The low octanol-water partitioning coefficient and the high water solubility suggested a low bioaccumulation potential and the water compartment as its main environmental recipient and capacitor. Preliminary ecotoxicological tests did not highlight direct toxicity effects toward Daphnia magna. For green algae Pseudokirchneriella subcapitata an effect was observed at concentrations above 100 mg/L with a significant growth of protozoa that may be connected to a concurrent algal growth inhibition.
Plasticized phenolphthalein polycarbonate
NASA Technical Reports Server (NTRS)
Harrison, E. S.
1976-01-01
Phenolphthalein polycarbonate was successfully plasticized with polychlorinated biphenyls (e.g., Aroclor 1231) or tricresyl phosphate and cast from tetrahydrofuran to give clear films without loss of fire resistance. At loadings of 20 to 30 percent plasticizer the Tg was lowered to approximately 100 C which would render phenolphthalein polycarbonate easily moldable. Although these materials had some mechanical integrity as shown by their film forming ability, the room temperature toughness of the plasticized polymer was not significantly improved over unmodified polymer.
2014-08-14
to 5a. CONTRACT NUMBER In-House Thermosetting and Thermoplastic Polymers based on Bisphenol A 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6...Francisco, CA, 14 August 2014. PA#14389 14. ABSTRACT Polycyanurate thermosetting networks, polycarbonate thermoplastics, and homogenous polycarbonate...ON EUGENOL: ALTERNATIVES TO THERMOSETTING AND THERMOPLASTIC POLYMES BASED ON BISPHENOL A 14 August 2014 Andrew J. Guenthner1, Benjamin G. Harvey2
Ingram, D T; Lamichhane, C M; Rollins, D M; Carr, L E; Mallinson, E T; Joseph, S W
1998-07-01
E. coli O157:H7 is a food-borne adulterant that can cause hemorrhagic ulcerative colitis and hemolytic uremic syndrome. Faced with an increasing risk of foods contaminated with E. coli O157:H7, food safety officials are seeking improved methods to detect and isolate E. coli O157:H7 in hazard analysis and critical control point systems in meat- and poultry-processing plants. A colony lift immunoassay was developed to facilitate the positive identification and quantification of E. coli O157:H7 by incorporating a simple colony lift enzyme-linked immunosorbent assay with filter monitors and traditional culture methods. Polyvinylidene difluoride (PVDF) membranes (Millipore, Bedford, Mass.) were prewet with methanol and were used to make replicates of every bacterial colony on agar plates or filter monitor membranes that were then reincubated for 15 to 18 h at 36 +/- 1 degree C, during which the colonies not only remained viable but were reestablished. The membranes were dried, blocked with blocking buffer (Kirkegaard and Perry Laboratories [KPL], Gaithersburg, Md.), and exposed for 7 min to an affinity-purified horseradish peroxidase-labeled goat anti-E. coli O157 antibody (KPL). The membranes were washed, exposed to a 3,3',5,5'-tetramethylbenzidine membrane substrate (TMB; KPL) or aminoethyl carbazole (AEC; Sigma Chemical Co., St. Louis, Mo.), rinsed in deionized water, and air dried. Colonies of E. coli O157:H7 were identified by either a blue (via TMB) or a red (via AEC) color reaction. The colored spots on the PVDF lift membrane were then matched to their respective parent colonies on the agar plates or filter monitor membranes. The colony lift immunoassay was tested with a wide range of genera in the family Enterobacteriaceae as well as different serotypes within the E. coli genus. The colony lift immunoassay provided a simple, rapid, and accurate method for confirming the presence of E. coli O157:H7 colonies isolated on filter monitors or spread plates by traditional culture methods. An advantage of using the colony lift immunoassay is the ability to test every colony serologically on an agar plate or filter monitor membrane simultaneously for the presence of the E. coli O157 antigen. This colony lift immunoassay has recently been successfully incorporated into a rapid-detection, isolation, and quantification system for E. coli O157:H7, developed in our laboratories for retail meat sampling.
Ingram, David T.; Lamichhane, Chinta M.; Rollins, David M.; Carr, Lewis E.; Mallinson, Edward T.; Joseph, Sam W.
1998-01-01
E. coli O157:H7 is a food-borne adulterant that can cause hemorrhagic ulcerative colitis and hemolytic uremic syndrome. Faced with an increasing risk of foods contaminated with E. coli O157:H7, food safety officials are seeking improved methods to detect and isolate E. coli O157:H7 in hazard analysis and critical control point systems in meat- and poultry-processing plants. A colony lift immunoassay was developed to facilitate the positive identification and quantification of E. coli O157:H7 by incorporating a simple colony lift enzyme-linked immunosorbent assay with filter monitors and traditional culture methods. Polyvinylidene difluoride (PVDF) membranes (Millipore, Bedford, Mass.) were prewet with methanol and were used to make replicates of every bacterial colony on agar plates or filter monitor membranes that were then reincubated for 15 to 18 h at 36 ± 1°C, during which the colonies not only remained viable but were reestablished. The membranes were dried, blocked with blocking buffer (Kirkegaard and Perry Laboratories [KPL], Gaithersburg, Md.), and exposed for 7 min to an affinity-purified horseradish peroxidase-labeled goat anti-E. coli O157 antibody (KPL). The membranes were washed, exposed to a 3,3′,5,5′-tetramethylbenzidine membrane substrate (TMB; KPL) or aminoethyl carbazole (AEC; Sigma Chemical Co., St. Louis, Mo.), rinsed in deionized water, and air dried. Colonies of E. coli O157:H7 were identified by either a blue (via TMB) or a red (via AEC) color reaction. The colored spots on the PVDF lift membrane were then matched to their respective parent colonies on the agar plates or filter monitor membranes. The colony lift immunoassay was tested with a wide range of genera in the family Enterobacteriaceae as well as different serotypes within the E. coli genus. The colony lift immunoassay provided a simple, rapid, and accurate method for confirming the presence of E. coli O157:H7 colonies isolated on filter monitors or spread plates by traditional culture methods. An advantage of using the colony lift immunoassay is the ability to test every colony serologically on an agar plate or filter monitor membrane simultaneously for the presence of the E. coli O157 antigen. This colony lift immunoassay has recently been successfully incorporated into a rapid-detection, isolation, and quantification system for E. coli O157:H7, developed in our laboratories for retail meat sampling. PMID:9665968
DOE Office of Scientific and Technical Information (OSTI.GOV)
Oji, L.; Martin, K.; Hobbs, D.
2012-01-03
Experimental results for the selective removal of strontium and cesium from simulated waste solutions with monosodium titanate and crystalline silicotitanate laden filter cartridges are presented. In these proof-of-principle tests, effective uptake of both strontium-85 and cesium-137 were observed using ion-exchangers in this filter cartridge configuration. At low salt simulant conditions, the instantaneous decontamination factor for strontium-85 with monosodium titanate impregnated filter membrane cartridges measured 26, representing 96% strontium-85 removal efficiency. On the other hand, the strontium-85 instantaneous decontamination factor with co-sintered active monosodium titanate cartridges measured 40 or 98% Sr-85 removal efficiency. Strontium-85 removal with the monosodium titanate impregnated membranemore » cartridges and crystalline silicotitanate impregnated membrane cartridges, placed in series arrangement, produced an instantaneous decontamination factor of 41 compared to an instantaneous decontamination factor of 368 for strontium-85 with co-sintered active monosodium titanate cartridges and co-sintered active crystalline silicotitanate cartridges placed in series. Overall, polyethylene co-sintered active titanates cartridges performed as well as titanate impregnated filter membrane cartridges in the uptake of strontium. At low ionic strength conditions, there was a significant uptake of cesium-137 with co-sintered crystalline silicotitanate cartridges. Tests results with crystalline silicotitanate impregnated membrane cartridges for cesium-137 decontamination are currently being re-evaluated. Based on these preliminary findings we conclude that incorporating monosodium titanate and crystalline silicotitanate sorbents into membranes represent a promising method for the semicontinuous removal of radioisotopes of strontium and cesium from nuclear waste solutions.« less
Synthesis of Polyurethanes Membranes from Rubber Seed Oil and Methylene Diphenyl Diisocyanates (MDI)
NASA Astrophysics Data System (ADS)
Marlina; Nurman, S.; Saleha, S.; Fitriani; Thanthawi, I.
2017-03-01
Rubber seed oil and methylene diphenyl diisocyanates (MDI) based polyurethane membrane has been prepared in this study. The main objective of this research is manufacture of polyurethane membranes from avocado seed oil, as a filter of this membrane use as a filter of metals from water such as mercury (Hg). In this study, the polyurethane membrane had been synthesized by varying compositions of rubber seed oil and MDI, with ratios of 10:0.2; 10:0.4; 10:0.6; 10:0.8; 10:1.0; 10:1.2; 10:1.4; 10:1.6; 10:1.8 and 10:2.0 (v/w) at 80°C and 170°C as polymerization and curing temperatures, respectively. Optimum polyurethane membrane was obtained at rubber seed oil: MDI 10: 0.8 v/w, it was dry, non-sticky, smooth and blackish brown. The membrane flux was 5,8307 L / m2.h.bar and rejection factor was 35,3015 %. The results of characterization indicated the formation of urethane bonds (NH at 3480 cm-1, C=O at 1620 cm-1, CN at 1374 cm-1, -OC-NH- at 1096 cm-1 and no -NCO at 2270 cm-1), the value of Tg was 55°C. The polyurethane membrane which treated at the optimum treatment conditions were used to the filter of metals from water such as mercury (Hg).
A membrane filtering method for the purification of giant unilamellar vesicles.
Tamba, Yukihiro; Terashima, Hiroaki; Yamazaki, Masahito
2011-07-01
The use of giant unilamellar vesicles (GUVs) for investigating the properties of biomembranes is advantageous compared to the use of small-sized vesicles such as large unilamellar vesicles (LUVs). Experimental methods using GUVs, such as the single GUV method, would benefit if there was a methodology for obtaining a large population of similar-sized GUVs composed of oil-free membranes. We here describe a new membrane filtering method for purifying GUVs prepared by the natural swelling method and demonstrate that, following purification of GUVs composed of dioleoylphosphatidylglycerol (DOPG)/dioleoylphosphatidylcholine (DOPC) membranes suspended in a buffer, similar-sized GUVs with diameters of 10-30 μm are obtained. Moreover, this method enabled GUVs to be separated from water-soluble fluorescent probes and LUVs. These results suggest that the membrane filtering method can be applied to GUVs prepared by other methods to purify larger-sized GUVs from smaller GUVs, LUVs, and various water-soluble substances such as proteins and fluorescent probes. This method can also be used for concentration of dilute GUV suspensions. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.
Drinking water regulations under the Final Coliform Rule require that total coliform-positive drinking water samples be examined for the presence of Escherichia coli or fecal coliforms. The current U.S. Environmental Protection Agency-approved membrane filter (MF) method for E. c...
A new membrane filter (MF) medium, MI agar, recently validated for use in recovering chlorine-damaged total coloiforms (TC) and Escherichia coli from drinking water, was compared to the US Environmental Protection Agency (EPA)-approved MF method(mEndo agar and nutrient agar suppl...
Application of a low cost ceramic filter to a membrane bioreactor for greywater treatment.
Hasan, Md Mahmudul; Shafiquzzaman, Md; Nakajima, Jun; Ahmed, Abdel Kader T; Azam, Mohammad Shafiul
2015-03-01
The performance of a low cost and simple ceramic filter to a membrane bioreactor (MBR) process was evaluated for greywater treatment. The ceramic filter was submerged in an acrylic cylindrical column bioreactor. Synthetic greywater (prepared by shampoo, dish cleaner and laundry detergent) was fed continuously into the reactor. The filter effluent was obtained by gravitational pressure. The average flux performance was observed to be 11.5 LMH with an average hydraulic retention time of 1.7 days. Complete biodegradation of surfactant (methylene blue active substance removal: 99-100%) as well as high organic removal performance (biochemical oxygen demand: 97-100% and total organic carbon: >88%) was obtained. The consistency of flux (11.5 LMH) indicated that the filter can be operated for a long time without fouling. The application of this simple ceramic filter would make MBR technology cost-effective in developing countries for greywater reclamation and reuse.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Vesper, Stephen; McKinstry, Craig A.; Hartmann, Chris
2007-11-28
A method is described to discriminate between live and dead cells of the infectious fungi Aspergillus fumigatus, Aspergillus flavus, Aspergillus terreus, Mucor racemosus, Rhizopus stolonifer and Paecilomyces variotii. To test the method, conidial suspensions were heat inactivated at 85 °C or held at 5 °C (controls) for 1 h. Polycarbonate filters (25 mm diameter, 0.8 μm pore size) were placed on "welled" slides (14 mm diameter) and the filters treated with either PBS or PMA. Propidium monoazide (PMA), which enters dead cells but not live cells, was incubated with cell suspensions, exposed to blue wavelength light-emitting diodes (LED) to inactivatemore » remaining PMA and secure intercalation of PMAwith DNA of dead cells. Treated cells were extracted and the live and dead cells evaluated with quantitative PCR (QPCR). After heat treatment and DNA modification with PMA, all fungal species tested showed an approximate 100- to 1000-fold difference in cell viability estimated by QPCR analysis which was consistent with estimates of viability based on culturing.« less
A Novel Anti-Pollution Filter for Volatile Agents During Cardiopulmonary Bypass: Preliminary Tests.
Nigro Neto, Caetano; Landoni, Giovanni; Tardelli, Maria Angela
2017-08-01
Concerns regarding pollution of the operating room by volatile anesthetics and effects on atmospheric ozone depletion exist. Volatile agents commonly are used during cardiopulmonary bypass to provide anesthesia independent of any supposed myocardial protective effects. The authors' aim was to create and to assess the performance of a prototype filter for volatile agents to be connected to the cardiopulmonary bypass circuit to avoid the emission of volatile agents to the operating room, and also to the environment without causing damage to the membrane oxygenator. Observational trial. University hospital. Prototype filter for volatile agents. The prototype filter was tested in a single ex vivo experiment. The main data measured during the test were pressure drop to detect interference with the performance of the oxygenator, back pressure to detect overpressure to the outlet gas jacket of the oxygenator, analysis of exhaled sevoflurane after the membrane oxygenator, and after the filter to detect any presence of sevoflurane. The prototype filter adsorbed the sevoflurane eliminated through the outlet portion of the oxygenator. During the entire test, the back pressure remained constant (4 mmHg) and pressure drop varied from 243 mmHg to 247 mmHg. The prototype filter was considered suitable to absorb the sevoflurane, and it did not cause an overpressure to the membrane oxygenator during the test. Copyright © 2017 Elsevier Inc. All rights reserved.
Low-autofluorescence fluoropolymer membrane filters for cell filtration
NASA Astrophysics Data System (ADS)
Kihara, Naoto; Kuboyama, Daiki; Onoshima, Daisuke; Ishikawa, Kenji; Tanaka, Hiromasa; Ozawa, Naoya; Hase, Tetsunari; Koguchi, Ryohei; Yukawa, Hiroshi; Odaka, Hidefumi; Hasegawa, Yoshinori; Baba, Yoshinobu; Hori, Masaru
2018-06-01
A fluoropolymer membrane filter with through-holes was fabricated by photolithographic patterning and the dry etching method. 380,000 highly packed through-holes, each with a diameter of 7 µm were able to cover a whole area with a diameter of 13 mm. Ethylene tetrafluoroethylene (ETFE) was used as the membrane, which was suitable for the fluorescence detection of rare cells such as circulating tumor cells (CTCs) in human blood. The device fabrication for the size based capture of rare cells in blood such as CTCs is realized in this study.
Nanoceramics for blood-borne virus removal.
Zhao, Yufeng; Sugiyama, Sadahiro; Miller, Thomas; Miao, Xigeng
2008-05-01
The development of nanoscience and nanotechnology in the field of ceramics has brought new opportunities for the development of virus-removal techniques. A number of nanoceramics, including nanostructured alumina, titania and zirconia, have been introduced for the applications in virus removal or separation. Filtration or adsorption of viruses, and thus the removal of viruses through nanoceramics, such as nanoporous/mesoporous ceramic membranes, ceramic nanofibers and ceramic nanoparticles, will make it possible to produce an efficient system for virus removal from blood and one with excellent chemical/thermal stability. Currently, nanoceramic membranes and filters based on sol-gel alumina membranes and NanoCeram nanofiber filters have been commercialized and applied to remove viruses from the blood. Nevertheless, filtration using nanoporous filters is limited to the removal of only free viruses in the bloodstream.
The relative fire resistance of select thermoplastic materials. [for aircraft interiors
NASA Technical Reports Server (NTRS)
Kourtides, D. A.; Parker, J. A.
1978-01-01
The relative thermal stability, flammability, and related thermochemical properties of some thermoplastic materials currently used in aircraft interiors as well as of some candidate thermoplastics were investigated. Currently used materials that were evaluated include acrylonitrile butadiene styrene, bisphenol A polycarbonate, polyphenylene oxide, and polyvinyl fluoride. Candidate thermoplastic materials evaluated include: 9,9-bis(4-hydroxyphenyl)fluorene polycarbonate-poly(dimethylsiloxane) block polymer, chlorinated polyvinylchloride homopolymer, phenolphthalein polycarbonate, polyethersulfone, polyphenylene sulfide, polyarylsulfone, and polyvinylidene fluoride.
Stabilized nonlinear optical chromophore alignment in high-? guest - host polycarbonates
NASA Astrophysics Data System (ADS)
Healy, D.; Bloor, D.; Gray, D.; Cross, G. H.
1997-11-01
Electric-field-poling studies of two polycarbonates doped with 2-(N,N dimethylamino)-5-nitroacetanilide revealed a long-term room-temperature alignment stability. This stability at room temperature is compared with that of similarly doped poly(methyl methacrylate) (PMMA) which displays short-term relaxation. Despite several previous suggestions that hydrogen bonding between guest and host plays a major role in these effects, infra-red spectroscopic studies refuted the idea that stronger hydrogen bond formation in the polycarbonate rather than in PMMA is the dominant influence. Rather we show, using an examination of the poling currents during poling, that the re-orientation dynamics in the polycarbonate systems are markedly different. In the case of PMMA-doped films, the deposited surface charge is compensated by poling currents at a rate at least comparable to the rate of deposition of corona charge. The compensation rate for polycarbonate-doped systems was markedly lower, however, suggesting that polar re-orientation is slower. Studies of the second-order optical nonlinearities of poled thin films using second-harmonic generation revealed an apparent enhancement of the second-harmonic coefficient compared with the predictions of conventional theories. However, we note that the use of microscopic parameters (the dipole moment and the first hyperpolarizability) obtained from measurements in non-dipolar media may give rise to the apparent anomaly since high reaction fields in polycarbonate films may act to modify these parameters.
Constitutive modeling of polycarbonate over a wide range of strain rates and temperatures
NASA Astrophysics Data System (ADS)
Wang, Haitao; Zhou, Huamin; Huang, Zhigao; Zhang, Yun; Zhao, Xiaoxuan
2017-02-01
The mechanical behavior of polycarbonate was experimentally investigated over a wide range of strain rates (10^{-4} to 5× 103 s^{-1}) and temperatures (293 to 353 K). Compression tests under these conditions were performed using a SHIMADZU universal testing machine and a split Hopkinson pressure bar. Falling weight impact testing was carried out on an Instron Dynatup 9200 drop tower system. The rate- and temperature-dependent deformation behavior of polycarbonate was discussed in detail. Dynamic mechanical analysis (DMA) tests were utilized to observe the glass (α ) transition and the secondary (β ) transition of polycarbonate. The DMA results indicate that the α and β transitions have a dramatic influence on the mechanical behavior of polycarbonate. The decompose/shift/reconstruct (DSR) method was utilized to decompose the storage modulus into the α and β components and extrapolate the entire modulus, the α-component modulus and the β-component modulus. Based on three previous models, namely, Mulliken-Boyce, G'Sell-Jonas and DSGZ, an adiabatic model is proposed to predict the mechanical behavior of polycarbonate. The model considers the contributions of both the α and β transitions to the mechanical behavior, and it has been implemented in ABAQUS/Explicit through a user material subroutine VUMAT. The model predictions are proven to essentially coincide with the experimental results during compression testing and falling weight impact testing.
Zhou, Xiao-Xia; Lai, Yu-Jian; Liu, Rui; Li, Sha-Sha; Xu, Jing-Wen; Liu, Jing-Fu
2017-12-05
Efficient separation and preconcentration of trace nanoparticulate silver (NAg) from large-volume environmental waters is a prerequisite for reliable analysis and therefore understanding the environmental processes of silver nanoparticles (AgNPs). Herein, we report the novel use of polyvinylidene fluoride (PVDF) filter membrane for disk-based solid phase extraction (SPE) of NAg in 1 L of water samples with the disk-based SPE system, which consists of a syringe pump and a syringe filter holder to embed the filter membrane. While the PVDF membrane can selectively adsorb NAg in the presence of Ag + , aqueous solution of 2% (m/v) FL-70 is found to efficiently elute NAg. Analysis of NAg is performed following optimization of filter membrane and elution conditions with an enrichment factor of 1000. Additionally, transmission electron microscopy (TEM), UV-vis spectroscopy, and size-exclusion chromatography coupled with ICP-MS (SEC-ICP-MS) analysis showed that the extraction gives rise to no change in NAg size or shape, making this method attractive for practical applications. Furthermore, feasibility of the protocol is verified by applying it to extract NAg in four real waters with recoveries of 62.2-80.2% at 0.056-0.58 μg/L spiked levels. This work will facilitate robust studies of trace NAg transformation and their hazard assessments in the environment.
Liu, Shunjie; Zhao, Xun; Guo, Hongchen; Qin, Yusheng; Wang, Xianhong; Wang, Fosong
2017-05-01
Due to the axial group initiation in traditional (salen)CoX/quaternary ammonium catalyst system, it is difficult to construct single active center propagating polycarbonates for copolymerization of CO 2 /epoxides. Here a redox-responsive poly(vinyl cyclohexene carbonate) (PVCHC) with detachable disulfide-bond backbone is synthesized in a controllable manner using (salen)CoTFA/[bis(triphenylphosphine)iminium, [PPN]TFA binary catalyst, where the axial group initiation is depressed by judiciously choosing 3,3'-dithiodipropionic acid as starter. While for those comonomers failing to obtain polycarbonate with unimodal gel permeation chromatography (GPC) curve, a versatile method is developed by combination of immortal copolymerization and prereaction approach, and functional aliphatic polycarbonates having well-defined architecture and narrow polydispersity can be prepared. The resulting PVCHC can be further functionalized with alkenes by versatile cross-metathesis reaction to tune the physicochemical properties. The combination of immortal polymerization and prereaction approach creates a powerful platform for controllable synthesis of functional CO 2 -based polycarbonates. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
40 CFR 141.711 - Filtered system additional Cryptosporidium treatment requirements.
Code of Federal Regulations, 2011 CFR
2011-07-01
... either one or a combination of the following: bag filters, bank filtration, cartridge filters, chlorine dioxide, membranes, ozone, or UV, as described in §§ 141.716 through 141.720. (c) Failure by a system in...
40 CFR 141.711 - Filtered system additional Cryptosporidium treatment requirements.
Code of Federal Regulations, 2010 CFR
2010-07-01
... either one or a combination of the following: bag filters, bank filtration, cartridge filters, chlorine dioxide, membranes, ozone, or UV, as described in §§ 141.716 through 141.720. (c) Failure by a system in...
Experimental and computational investigation of lateral gauge response in polycarbonate
NASA Astrophysics Data System (ADS)
Eliot, Jim; Harris, Ernest Joseph; Hazell, Paul; Appleby-Thomas, Gareth James; Winter, Ron; Wood, David Christopher
2012-03-01
The shock behaviour of polycarbonate is of interest due to its extensive use in defence applications. Interestingly, embedded lateral manganin stress gauges in polycarbonate have shown gradients behind incident shocks, suggestive of increasing shear strength. However, such gauges are commonly embedded in a central epoxy interlayer. This is an inherently invasive approach. Recently, research has suggested that in such systems interlayer/target impedance may contribute to observed gradients in lateral stress. Here, experimental T-gauge (Vishay Micro-Measurements® type J2M-SS-580SF-025) traces from polycarbonate targets are compared to computational simulations. The effects of gauge environment are investigated by looking at the response of lateral gauges with both standard "glued-joint" and a "dry joint" encapsulation, where no encapsulating medium is employed.
Huang, Ming; Zhang, Yuxin; Li, Fei; Zhang, Lili; Ruoff, Rodney S.; Wen, Zhiyu; Liu, Qing
2014-01-01
Porous nanotubes comprised of MnO2 nanosheets were fabricated with a one-pot hydrothermal method using polycarbonate membrane as the template. The diameter and thickness of nanotubes can be controlled by choice of the membrane pore size and the chemistry. The porous MnO2 nanotubes were used as a supercapacitor electrode. The specific capacitance in a three-electrode system was 365 F g−1 at a current density of 0.25 A g−1 with capacitance retention of 90.4% after 3000 cycles. An asymmetric supercapacitor with porous MnO2 nanotubes as the positive electrode and activated graphene as the negative electrode yielded an energy density of 22.5 Wh kg−1 and a maximum power density of 146.2 kW kg−1; these values exceeded those reported for other MnO2 nanostructures. The supercapacitor performance was correlated with the hierarchical structure of the porous MnO2 nanotubes. PMID:24464344
Influence of size, shape, and flexibility on bacterial passage through micropore membrane filters.
Wang, Yingying; Hammes, Frederik; Düggelin, Marcel; Egli, Thomas
2008-09-01
Sterilization of fluids by means of microfiltration is commonly applied in research laboratories as well as in pharmaceutical and industrial processes. Sterile micropore filters are subject to microbiological validation, where Brevundimonas diminuta is used as a standard test organism. However, several recent reports on the ubiquitous presence of filterable bacteria in aquatic environments have cast doubt on the accuracy and validity of the standard filter-testing method. Six different bacterial species of various sizes and shapes (Hylemonella gracilis, Escherichia coli, Sphingopyxis alaskensis, Vibrio cholerae, Legionella pneumophila, and B. diminuta) were tested for their filterability through sterile micropore filters. In all cases, the slender spirillum-shaped Hylemonella gracilis cells showed a superior ability to pass through sterile membrane filters. Our results provide solid evidence that the overall shape (including flexibility), instead of biovolume, is the determining factor for the filterability of bacteria, whereas cultivation conditions also play a crucial role. Furthermore, the filtration volume has a more important effect on the passage percentage in comparison with other technical variables tested (including flux and filter material). Based on our findings, we recommend a re-evaluation of the grading system for sterile filters, and suggest that the species Hylemonella should be considered as an alternative filter-testing organism for the quality assessment of micropore filters.
Sensors and filters based on nano- and microchannel membranes for biomedical technologies
NASA Astrophysics Data System (ADS)
Romanov, S. I.; Pyshnyi, D. V.; Laktionov, P. P.
2012-02-01
A new technology is presented in a concise form which enables the silicon membranes to be produced over a wide range of channel dimensions from a few nanometers to tens of micrometers. There is good reason to believe that this method based on rather simple technical processing is competitive with other technologies for fabricating nanofluidic analysis systems. Some of the completed developments involving microchannel membranes, namely, the optical DNA-sensor and the human cell separation system are demonstrated without going into details. The other applications of micro- and nanochannel membranes, namely, the electrical sensor and electrokinetic filters for detecting and separating liquids and biomolecules are shown with the first results and are in progress.
NASA Astrophysics Data System (ADS)
Masturi; Widodo, R. D.; Edie, S. S.; Amri, U.; Sidiq, A. L.; Alighiri, D.; Wulandari, N. A.; Susilawati; Amanah, S. N.
2018-03-01
Problem of pollution in water continues in Indonesia, with its manufacturing sector as biggest contributor to economic growth. One out of many technological solutions is post-treating industrial wastewater by membrane filtering technology. We presented a result of our fabrication of ceramic membrane made from zeolite with simple mixing and he. At 5% of (poring agent):(total weight), its permeability stays around 2.8 mD (10‑14m2) with slight variance around it, attributed to the mixture being in far below percolating threshold. All our membranes achieve remarkable above 90% rejection rate of methylene blue as solute waste in water solvent.
Interfacial adhesion of carbon fibers
NASA Technical Reports Server (NTRS)
Bascom, Willard D.
1987-01-01
Relative adhesion strengths between AS4, AS1, and XAS carbon fibers and thermoplastic polymers were determined using the embedded single filament test. Polymers studied included polycarbonate, polyphenylene oxide, polyetherimide, polysulfone, polyphenylene oxide blends with polystyrene, and polycarbonate blends with a polycarbonate polysiloxane block copolymer. Fiber surface treatments and sizings improved adhesion somewhat, but adhesion remained well below levels obtained with epoxy matrices. An explanation for the differences between the Hercules and Grafil fibers was sought using X ray photon spectroscopy, wetting, scanning electron microscopy and thermal desorption analysis.
Bisphenol A polycarbonate as a reference material
NASA Technical Reports Server (NTRS)
Hilado, C. J.; Cumming, H. J.; Williams, J. B.
1977-01-01
Test methods require reference materials to standardize and maintain quality control. Various materials have been evaluated as possible reference materials, including a sample of bisphenol A polycarbonate without additives. Screening tests for relative toxicity under various experimental conditions were performed using male mice exposed to pyrolysis effluents over a 200-800 C temperature range. It was found that the bisphenol A polycarbonate served as a suitable reference material as it is available in large quantities, and does not significantly change with time.
DOE Office of Scientific and Technical Information (OSTI.GOV)
David Burnett; Harold Vance
2007-08-31
The goal of our project is to develop innovative processes and novel cleaning agents for water treatment facilities designed to remove fouling materials and restore micro-filter and reverse osmosis (RO) membrane performance. This project is part of Texas A&M University's comprehensive study of the treatment and reuse of oilfield brine for beneficial purposes. Before waste water can be used for any beneficial purpose, it must be processed to remove contaminants, including oily wastes such as residual petroleum hydrocarbons. An effective way of removing petroleum from brines is the use of membrane filters to separate oily waste from the brine. Texasmore » A&M and its partners have developed highly efficient membrane treatment and RO desalination for waste water including oil field produced water. We have also developed novel and new cleaning agents for membrane filters utilizing environmentally friendly materials so that the water from the treatment process will meet U.S. EPA drinking water standards. Prototype micellar cleaning agents perform better and use less clean water than alternate systems. While not yet optimized, the new system restores essentially complete membrane flux and separation efficiency after cleaning. Significantly the amount of desalinated water that is required to clean the membranes is reduced by more than 75%.« less
Morphology studies of hydrophobic silica on filter surface prepared via spray technique
NASA Astrophysics Data System (ADS)
Shahfiq Zulkifli, Nazrul; Zaini Yunos, Muhamad; Ahmad, Azlinnorazia; Harun, Zawati; Akhair, Siti Hajar Mohd; Adibah Raja Ahmad, Raja; Hafeez Azhar, Faiz; Rashid, Abdul Qaiyyum Abd; Ismail, Al Emran
2017-08-01
This study investigated the effect of the hydrophobic surface treatment effect of air filter performance by using silica aerogel powder as an additive by using spray coating techniques. The membrane characterization tests were carried out on a filter prepared from different additive concentration. Studies on the cross-section and the distribution of particles on the membrane were carried out using a scanning electron microscope (SEM), and the surface morphology was investigated by x-ray spectroscopy (EDS). The results are shown by SEM and EDS that the microstructure filter, especially in the upper layer and sub-layer has been changed. The results also show an increase of hydrophobicity due to the increased quantity of silica aerogel powder.
Nanoporous membranes with electrochemically switchable, chemically stabilized ionic selectivity
NASA Astrophysics Data System (ADS)
Small, Leo J.; Wheeler, David R.; Spoerke, Erik D.
2015-10-01
Nanopore size, shape, and surface charge all play important roles in regulating ionic transport through nanoporous membranes. The ability to control these parameters in situ provides a means to create ion transport systems tunable in real time. Here, we present a new strategy to address this challenge, utilizing three unique electrochemically switchable chemistries to manipulate the terminal functional group and control the resulting surface charge throughout ensembles of gold plated nanopores in ion-tracked polycarbonate membranes 3 cm2 in area. We demonstrate the diazonium mediated surface functionalization with (1) nitrophenyl chemistry, (2) quinone chemistry, and (3) previously unreported trimethyl lock chemistry. Unlike other works, these chemistries are chemically stabilized, eliminating the need for a continuously applied gate voltage to maintain a given state and retain ionic selectivity. The effect of surface functionalization and nanopore geometry on selective ion transport through these functionalized membranes is characterized in aqueous solutions of sodium chloride at pH = 5.7. The nitrophenyl surface allows for ionic selectivity to be irreversibly switched in situ from cation-selective to anion-selective upon reduction to an aminophenyl surface. The quinone-terminated surface enables reversible changes between no ionic selectivity and a slight cationic selectivity. Alternatively, the trimethyl lock allows ionic selectivity to be reversibly switched by up to a factor of 8, approaching ideal selectivity, as a carboxylic acid group is electrochemically revealed or hidden. By varying the pore shape from cylindrical to conical, it is demonstrated that a controllable directionality can be imparted to the ionic selectivity. Combining control of nanopore geometry with stable, switchable chemistries facilitates superior control of molecular transport across the membrane, enabling tunable ion transport systems.Nanopore size, shape, and surface charge all play important roles in regulating ionic transport through nanoporous membranes. The ability to control these parameters in situ provides a means to create ion transport systems tunable in real time. Here, we present a new strategy to address this challenge, utilizing three unique electrochemically switchable chemistries to manipulate the terminal functional group and control the resulting surface charge throughout ensembles of gold plated nanopores in ion-tracked polycarbonate membranes 3 cm2 in area. We demonstrate the diazonium mediated surface functionalization with (1) nitrophenyl chemistry, (2) quinone chemistry, and (3) previously unreported trimethyl lock chemistry. Unlike other works, these chemistries are chemically stabilized, eliminating the need for a continuously applied gate voltage to maintain a given state and retain ionic selectivity. The effect of surface functionalization and nanopore geometry on selective ion transport through these functionalized membranes is characterized in aqueous solutions of sodium chloride at pH = 5.7. The nitrophenyl surface allows for ionic selectivity to be irreversibly switched in situ from cation-selective to anion-selective upon reduction to an aminophenyl surface. The quinone-terminated surface enables reversible changes between no ionic selectivity and a slight cationic selectivity. Alternatively, the trimethyl lock allows ionic selectivity to be reversibly switched by up to a factor of 8, approaching ideal selectivity, as a carboxylic acid group is electrochemically revealed or hidden. By varying the pore shape from cylindrical to conical, it is demonstrated that a controllable directionality can be imparted to the ionic selectivity. Combining control of nanopore geometry with stable, switchable chemistries facilitates superior control of molecular transport across the membrane, enabling tunable ion transport systems. Electronic supplementary information (ESI) available: Experimental procedures, synthesis, and characterization of molecules 1, 2 and 3. Explanation of the electrochemical method for approximating nanopore diameter. Additional XPS spectra. See DOI: 10.1039/C5NR02939B
Elimination of gases and contamination from water
NASA Technical Reports Server (NTRS)
Buck, A. P.
1970-01-01
Filtration system with membrane type hydrophilic and hydrophobic filters gives absolute filtration with automatic venting of freed gases, and prevents backward transmission of contamination with no bacterial growth through the filters. Filter aids in degassing industrial solutions and in removing oxygen from sea water.
Yuen, Alexander; Wojtecki, Rudy J.; Hedrick, James L.; García, Jeannette M.
2016-01-01
It is estimated that ∼2.7 million tons poly(carbonate)s (PCs) are produced annually worldwide. In 2008, retailers pulled products from store shelves after reports of bisphenol A (BPA) leaching from baby bottles, reusable drink bottles, and other retail products. Since PCs are not typically recycled, a need for the repurposing of the PC waste has arisen. We report the one-step synthesis of poly(aryl ether sulfone)s (PSUs) from the depolymerization of PCs and in situ polycondensation with bis(aryl fluorides) in the presence of carbonate salts. PSUs are high-performance engineering thermoplastics that are commonly used for reverse osmosis and water purification membranes, medical equipment, as well as high temperature applications. PSUs generated through this cascade approach were isolated in high purity and yield with the expected thermal properties and represent a procedure for direct conversion of one class of polymer to another in a single step. Computational investigations performed with density functional theory predict that the carbonate salt plays two important catalytic roles in this reaction: it decomposes the PCs by nucleophilic attack, and in the subsequent polyether formation process, it promotes the reaction of phenolate dimers formed in situ with the aryl fluorides present. We envision repurposing poly(BPA carbonate) for the production of value-added polymers. PMID:27354514
Leeladhar; Raturi, Parul; Singh, J P
2018-02-27
Photomechanical actuation is the conversion of light energy into mechanical energy through some smart materials. Infrared-responsive smart materials have become an emerging field of research due to easy availability and eco-friendly nature of their stimulus in the form of sunlight, which contains about 50% of near-infrared(nIR) making these materials useful at macro-scale photoactuator applications. Here, we demonstrate fabrication of highly versatile nIR triggered photoactuators based on graphene oxide/polycarbonate bilayers that offers fast, low-cost fabrication, large deflection, reversible actuation and wavelength-selective response. The photoactuators are realized by vacuum filtration of graphene oxide/water dispersion through polycarbonate membrane resulting graphene oxide/polymer bilayer structure. The photoactuation response was measured in the form of deflection from equilibrium position as a result of infrared-irradiation. The deflection is caused by the generated thermal stress at the interface of bilayers due to mismatch of thermal expansion coefficient as a results of nIR absorption by graphene oxide and subsequent temperature rise. A maximum deflection of 12 mm (circular-shaped structure with diameter 28 mm) with corresponding bending curvature of 0.33 cm -1 was shown by this photoactuator for illumination intensity of 106 mW/cm 2 . Few applications of these photoactuators such as sunlight-driven smart curtain, infrared actuated curtain and self-folding box are also demonstrated.
Jones, Gavin O; Yuen, Alexander; Wojtecki, Rudy J; Hedrick, James L; García, Jeannette M
2016-07-12
It is estimated that ∼2.7 million tons poly(carbonate)s (PCs) are produced annually worldwide. In 2008, retailers pulled products from store shelves after reports of bisphenol A (BPA) leaching from baby bottles, reusable drink bottles, and other retail products. Since PCs are not typically recycled, a need for the repurposing of the PC waste has arisen. We report the one-step synthesis of poly(aryl ether sulfone)s (PSUs) from the depolymerization of PCs and in situ polycondensation with bis(aryl fluorides) in the presence of carbonate salts. PSUs are high-performance engineering thermoplastics that are commonly used for reverse osmosis and water purification membranes, medical equipment, as well as high temperature applications. PSUs generated through this cascade approach were isolated in high purity and yield with the expected thermal properties and represent a procedure for direct conversion of one class of polymer to another in a single step. Computational investigations performed with density functional theory predict that the carbonate salt plays two important catalytic roles in this reaction: it decomposes the PCs by nucleophilic attack, and in the subsequent polyether formation process, it promotes the reaction of phenolate dimers formed in situ with the aryl fluorides present. We envision repurposing poly(BPA carbonate) for the production of value-added polymers.
Ford, Audrey C; Gramling, Hannah; Li, Samuel C; Sov, Jessica V; Srinivasan, Amrita; Pruitt, Lisa A
2018-03-01
Polycarbonate polyurethane has cartilage-like, hygroscopic, and elastomeric properties that make it an attractive material for orthopedic joint replacement application. However, little data exists on the cyclic loading and fracture behavior of polycarbonate polyurethane. This study investigates the mechanisms of fatigue crack growth in polycarbonate polyurethane with respect to time dependent effects and conditioning. We studied two commercially available polycarbonate polyurethanes, Bionate® 75D and 80A. Tension testing was performed on specimens at variable time points after being removed from hydration and variable strain rates. Fatigue crack propagation characterized three aspects of loading. Study 1 investigated the impact of continuous loading (24h/day) versus intermittent loading (8-10h/day) allowing for relaxation overnight. Study 2 evaluated the effect of frequency and study 3 examined the impact of hydration on the fatigue crack propagation in polycarbonate polyurethane. Samples loaded intermittently failed instantaneously and prematurely upon reloading while samples loaded continuously sustained longer stable cracks. Crack growth for samples tested at 2 and 5Hz was largely planar with little crack deflection. However, samples tested at 10Hz showed high degrees of crack tip deflection and multiple crack fronts. Crack growth in hydrated samples proceeded with much greater ductile crack mouth opening displacement than dry samples. An understanding of the failure mechanisms of this polymer is important to assess the long-term structural integrity of this material for use in load-bearing orthopedic implant applications. Copyright © 2018 Elsevier Ltd. All rights reserved.
Chou, B Ralph; Gupta, Alina; Hovis, Jeffery K
2005-11-01
Previous work has shown that the impact resistance to blunt missiles is affected by coatings applied to either CR-39 or polycarbonate lenses. We investigated the effects of multiple antireflection (minimum angle of resolution [MAR]) coatings on the resistance of polycarbonate lenses to puncture on impact by sharp, high-speed missiles. Four groups of surfaced plano polycarbonate lenses were investigated. Two groups had a scratch-resistant (SR) coating applied to both surfaces. One of these groups had a 2-mm center thickness and the other had a 3-mm center thickness. The other two groups of 2-mm and 3-mm thick lenses had a MAR coating applied over the SR coating. The lenses were impacted by a missile consisting of an industrial sewing machine needle mounted in a cylindrical aluminum carrier. The sharp missiles were able to pierce the lenses at speeds between 29.6 m/s and 46.2 m/s. Impact resistance was lowest for the thinner lenses and lenses with a MAR coating. The effect of the MAR and lens thickness was subadditive. We have confirmed previous observations that polycarbonate lenses are more susceptible to penetration by sharp, high-speed missiles than blunt missiles. We have also found that reducing lens center thickness and applying a MAR coating further reduces the penetration resistance. Therefore, the use of 2-mm center thickness and MAR-coated polycarbonate lenses should be discouraged for industrial eye protectors where sharp missile hazards are possible.
Triantou, Marianna I; Tarantili, Petroula A; Andreopoulos, Andreas G
2015-05-01
In the present research, blending of polymers used in electrical and electronic equipment, i.e. acrylonitrile-butadiene-styrene terpolymer, polycarbonate and polypropylene, was performed in a twin-screw extruder, in order to explore the effect process parameters on the mixture properties, in an attempt to determine some characteristics of a fast and economical procedure for waste management. The addition of polycarbonate in acrylonitrile-butadiene-styrene terpolymer seemed to increase its thermal stability. Also, the addition of polypropylene in acrylonitrile-butadiene-styrene terpolymer facilitates its melt processing, whereas the addition of acrylonitrile-butadiene-styrene terpolymer in polypropylene improves its mechanical performance. Moreover, the upgrading of the above blends by incorporating 2 phr organically modified montmorillonite was investigated. The prepared nanocomposites exhibit greater tensile strength, elastic modulus and storage modulus, as well as higher melt viscosity, compared with the unreinforced blends. The incorporation of montmorillonite nanoplatelets in polycarbonate-rich acrylonitrile-butadiene-styrene terpolymer/polycarbonate blends turns the thermal degradation mechanism into a two-stage process. Alternatively to mechanical recycling, the energy recovery from the combustion of acrylonitrile-butadiene-styrene terpolymer/polycarbonate and acrylonitrile-butadiene-styrene terpolymer/polypropylene blends was recorded by measuring the gross calorific value. Comparing the investigated polymers, polypropylene presents the higher gross calorific value, followed by acrylonitrile-butadiene-styrene terpolymer and then polycarbonate. The above study allows a rough comparative evaluation of various methodologies for treating plastics from waste from electrical and electronic equipment. © The Author(s) 2015.
Tobin, R S; Dutka, B J
1977-01-01
A comparative study was made of nine commonly used membrane filters from five manufacturers, all recommended for enumeration of coliform bacteria. Bacterial recoveries and flow rates were examined from three types of water and were found to correlate with the surface pore structure determined by scanning electron microscopy. The sorption of metals was also determined. The results of these studies indicate that the five best membranes for fecal coliform recovery could be placed in two groups: Millipore HC and Gelman, followed by Johns-Manville SG and AG and Sartorius 13806. Images PMID:329763
Verification testing of the US Filter 3M10C membrane system was conducted over a 44-day test period at the Aqua 2000 Research Center in Chula Vista, California. The test period extended from July 24, 2002 to September 5, 2002. The source water was a blend of Colorado River and ...
NASA Astrophysics Data System (ADS)
Liu, Zhikun; Cao, Zeyuan; Deng, Biwei; Wang, Yuefeng; Shao, Jiayi; Kumar, Prashant; Liu, C. Richard; Wei, Bingqing; Cheng, Gary J.
2014-05-01
Laser-induced photo-chemical synthesis of SnO2 nanotubes has been demonstrated by employing a nanoporous polycarbonate membrane as a template. The SnO2 nanotube diameter can be controlled by the nanoporous template while the nanotube length can be tuned by laser parameters and reaction duration. The microstructure characterization of the nanotubes indicates that they consist of mesoporous structures with sub 5 nm size nanocrystals connected by the twinning structure. The application of SnO2 nanotubes as an anode material in lithium ion batteries has also been explored, and they exhibited high capacity and excellent cyclic stability. The laser based emerging technique for scalable production of crystalline metal oxide nanotubes in a matter of seconds is remarkable. The compliance of the laser based technique with the existing technologies would lead to mass production of novel nanomaterials that would be suitable for several emerging applications.Laser-induced photo-chemical synthesis of SnO2 nanotubes has been demonstrated by employing a nanoporous polycarbonate membrane as a template. The SnO2 nanotube diameter can be controlled by the nanoporous template while the nanotube length can be tuned by laser parameters and reaction duration. The microstructure characterization of the nanotubes indicates that they consist of mesoporous structures with sub 5 nm size nanocrystals connected by the twinning structure. The application of SnO2 nanotubes as an anode material in lithium ion batteries has also been explored, and they exhibited high capacity and excellent cyclic stability. The laser based emerging technique for scalable production of crystalline metal oxide nanotubes in a matter of seconds is remarkable. The compliance of the laser based technique with the existing technologies would lead to mass production of novel nanomaterials that would be suitable for several emerging applications. Electronic supplementary information (ESI) available. See DOI: 10.1039/c3nr06444a
Sub-micron particle sampler apparatus and method for sampling sub-micron particles
Gay, D.D.; McMillan, W.G.
1984-04-12
Apparatus and method steps for collecting sub-micron sized particles include a collection chamber and cryogenic cooling. The cooling is accomplished by coil tubing carrying nitrogen in liquid form, with the liquid nitrogen changing to the gas phase before exiting from the collection chamber in the tubing. Standard filters are used to filter out particles of diameter greater than or equal to 0.3 microns; however, the present invention is used to trap particles of less than 0.3 micron in diameter. A blower draws air to said collection chamber through a filter which filters particles with diameters greater than or equal to 0.3 micron. The air is then cryogenically cooled so that moisture and sub-micron sized particles in the air condense into ice on the coil. The coil is then heated so that the ice melts, and the liquid is then drawn off and passed through a Buchner funnel where the liquid is passed through a Nuclepore membrane. A vacuum draws the liquid through the Nuclepore membrane, with the Nuclepore membrane trapping sub-micron sized particles therein. The Nuclepore membrane is then covered on its top and bottom surfaces with sheets of Mylar and the assembly is then crushed into a pellet. This effectively traps the sub-micron sized particles for later analysis. 6 figures.
Sub-micron particle sampler apparatus
Gay, Don D.; McMillan, William G.
1987-01-01
Apparatus and method steps for collecting sub-micron sized particles include a collection chamber and cryogenic cooling. The cooling is accomplished by coil tubing carrying nitrogen in liquid form, with the liquid nitrogen changing to the gas phase before exiting from the collection chamber in the tubing. Standard filters are used to filter out particles of diameter greater than or equal to 0.3 microns; however the present invention is used to trap particles of less than 0.3 micron in diameter. A blower draws air to said collection chamber through a filter which filters particles with diameters greater than or equal to 0.3 micron. The air is then cryogenically cooled so that moisture and sub-micron sized particles in the air condense into ice on the coil. The coil is then heated so that the ice melts, and the liquid is then drawn off and passed through a Buchner funnel where the liquid is passed through a Nuclepore membrane. A vacuum draws the liquid through the Nuclepore membrane, with the Nuclepore membrane trapping sub-micron sized particles therein. The Nuclepore membrane is then covered on its top and bottom surfaces with sheets of Mylar.RTM. and the assembly is then crushed into a pellet. This effectively traps the sub-micron sized particles for later analysis.
Method for sampling sub-micron particles
Gay, Don D.; McMillan, William G.
1985-01-01
Apparatus and method steps for collecting sub-micron sized particles include a collection chamber and cryogenic cooling. The cooling is accomplished by coil tubing carrying nitrogen in liquid form, with the liquid nitrogen changing to the gas phase before exiting from the collection chamber in the tubing. Standard filters are used to filter out particles of diameter greater than or equal to 0.3 microns; however the present invention is used to trap particles of less than 0.3 micron in diameter. A blower draws air to said collection chamber through a filter which filters particles with diameters greater than or equal to 0.3 micron. The air is then cryogenically cooled so that moisture and sub-micron sized particles in the air condense into ice on the coil. The coil is then heated so that the ice melts, and the liquid is then drawn off and passed through a Buchner funnel where the liquid is passed through a Nuclepore membrane. A vacuum draws the liquid through the Nuclepore membrane, with the Nuclepore membrane trapping sub-micron sized particles therein. The Nuclepore membrane is then covered on its top and bottom surfaces with sheets of Mylar.RTM. and the assembly is then crushed into a pellet. This effectively traps the sub-micron sized particles for later analysis.
Welding processes and ocular hazards and protection.
Pabley, A S; Keeney, A H
1981-07-01
There are approximately 60 different forms of welding, but only six of these are commonly used. Shielded metal-arc or stick welding, gas metal-arc welding, and oxyacetylene welding are the most frequently used. All produce ultraviolet, visible, and infrared radiation at damaging levels. Conventional glass welding shields contain ultraviolet, visible, and infrared absorbers. Infrared absorbers, however, cause heating and secondary re-radiation. New polycarbonate lenses offer greater impact resistance, and have less tendency to welding spatter. Early abrasion-resistant and reflective coatings on plastics were ineffective. Thin layers of gold with proprietary coatings provide cool reflection and surface resistance. Thermal monitoring of welding indicated that these new shields reduce temperature rises above the ambient by 150% to 175% compared to green glass filter plates without interfering with the welder's vision.
Ice nucleating particles in the high Arctic at the beginning of the melt season
NASA Astrophysics Data System (ADS)
Hartmann, M.; Gong, X.; Van Pinxteren, M.; Welti, A.; Zeppenfeld, S.; Herrmann, H.; Stratmann, F.
2017-12-01
Ice nucleating particles (INPs) initiate the ice crystal formation in persistent Arctic mixed-phase clouds and are important for the formation of precipitation, which affects the radiative properties of the Arctic pack ice as well as the radiative properties of clouds. Sources of Arctic INP have been suggested to be local emissions from the marine boundary and long-range transport. To what extent local marine sources contribute to the INP population or if the majority of INPs originate from long-range transport is not yet known. Ship-based INP measurements in the PASCAL framework are reported. The field campaign took place from May 24 to July 20 2017 around and north of Svalbard (up to 84°N, between 0° and 35°E) onboard the RV Polarstern. INP concentrations were determined applying in-situ measurements (DMT Spectrometer for Ice Nuclei, SPIN) and offline filter techniques (filter sampling on both quartz fiber and polycarbonate filters with subsequent analysis of filter pieces and water suspension from particles collected on filters by means of immersion freezing experiments on cold stage setups). Additionally the compartments sea-surface micro layer (SML), bulk sea water, snow, sea ice and fog water were sampled and their ice nucleation potential quantified, also utilizing cold stages. The measurements yield comprehensive picture of the spatial and temporal distribution of INPs around Svalbard for the different compartments. The dependence of the INP concentration on meteorological conditions (e.g. wind speed) and the geographical situation (sea ice cover, distance to the ice edge) are investigated. Potential sources of INP are identified by the comparison of INP concentrations in the compartments and by back trajectory analysis.
Eichmiller, Jessica J; Miller, Loren M; Sorensen, Peter W
2016-01-01
Few studies have examined capture and extraction methods for environmental DNA (eDNA) to identify techniques optimal for detection and quantification. In this study, precipitation, centrifugation and filtration eDNA capture methods and six commercially available DNA extraction kits were evaluated for their ability to detect and quantify common carp (Cyprinus carpio) mitochondrial DNA using quantitative PCR in a series of laboratory experiments. Filtration methods yielded the most carp eDNA, and a glass fibre (GF) filter performed better than a similar pore size polycarbonate (PC) filter. Smaller pore sized filters had higher regression slopes of biomass to eDNA, indicating that they were potentially more sensitive to changes in biomass. Comparison of DNA extraction kits showed that the MP Biomedicals FastDNA SPIN Kit yielded the most carp eDNA and was the most sensitive for detection purposes, despite minor inhibition. The MoBio PowerSoil DNA Isolation Kit had the lowest coefficient of variation in extraction efficiency between lake and well water and had no detectable inhibition, making it most suitable for comparisons across aquatic environments. Of the methods tested, we recommend using a 1.5 μm GF filter, followed by extraction with the MP Biomedicals FastDNA SPIN Kit for detection. For quantification of eDNA, filtration through a 0.2-0.6 μm pore size PC filter, followed by extraction with MoBio PowerSoil DNA Isolation Kit was optimal. These results are broadly applicable for laboratory studies on carps and potentially other cyprinids. The recommendations can also be used to inform choice of methodology for field studies. © 2015 John Wiley & Sons Ltd.
Anti-glomerular basement membrane blood test
... the part of the kidney that helps filter waste and extra fluid from the blood. Anti-glomerular basement membrane antibodies are antibodies against this membrane. They can lead to kidney damage. This article describes the blood test to detect these antibodies.
Nonlinear viscoelastic characterization of polycarbonate
NASA Technical Reports Server (NTRS)
Caplan, E. S.; Brinson, H. F.
1982-01-01
Uniaxial tensile creep and recovery data from polycarbonate at six temperatures and six stress levels are analyzed for nonlinear viscoelastic constitutive modeling. A theory to account for combined effects of two or more accelerating factors is presented.
21 CFR 175.365 - Vinylidene chloride copolymer coatings for polycarbonate film.
Code of Federal Regulations, 2012 CFR
2012-04-01
... or both sides of a base film produced from polycarbonate resins complying with § 177.1580 of this... vinylidene chloride with acrylonitrile, methyl acrylate, and acrylic acid. The finished copolymers contain at...
21 CFR 175.365 - Vinylidene chloride copolymer coatings for polycarbonate film.
Code of Federal Regulations, 2011 CFR
2011-04-01
... or both sides of a base film produced from polycarbonate resins complying with § 177.1580 of this... vinylidene chloride with acrylonitrile, methyl acrylate, and acrylic acid. The finished copolymers contain at...
21 CFR 175.365 - Vinylidene chloride copolymer coatings for polycarbonate film.
Code of Federal Regulations, 2013 CFR
2013-04-01
... or both sides of a base film produced from polycarbonate resins complying with § 177.1580 of this... vinylidene chloride with acrylonitrile, methyl acrylate, and acrylic acid. The finished copolymers contain at...
de Noronha, Bárbara Viero; Bergamini, Márcio Fernando; Marcolino Junior, Luiz Humberto; da Silva, Bruno José Gonçalves
2018-05-21
In this study, a simple, efficient, and reusable device based on cellulose membranes modified with polypyrrole was developed to extract 14 emerging contaminants from aqueous matrices. For chemical polymerization, a low-cost cellulose membrane was immersed in 0.1 mol L -1 pyrrole and 0.5 mol L -1 ammonium persulfate for 40 min in an ice/water bath. The cellulose membranes modified with polypyrrole were accommodated in a polycarbonate holder suitable for solid-phase extraction disks. Solid-phase extraction parameters that affect extraction efficiency, such as sample volume, pH, flow-rate, and desorption were optimized. Subsequently, determination of target compounds was performed by gas chromatography with mass spectrometry. The linear range for analytes ranged from 0.05 to 500 μg L -1 , with coefficients of determination above 0.990. The limits of quantification varied between 0.05 and 10 μg L -1 , with relative standard deviations lower than 17%. The performance of the proposed cellulose membranes modified with polypyrrole device for real samples was evaluated after extraction of emerging contaminants from a river water sample from the city of Curitiba-Brazil. Bisphenol A (6.39 μg L -1 ), caffeine (17.83 μg L -1 ), and paracetamol (19.28 μg L -1 ) were found in these samples. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.
Hu, Hua; Vervaeke, Koen; Graham, Lyle J; Storm, Johan F
2009-11-18
Synaptic input to a neuron may undergo various filtering steps, both locally and during transmission to the soma. Using simultaneous whole-cell recordings from soma and apical dendrites from rat CA1 hippocampal pyramidal cells, and biophysically detailed modeling, we found two complementary resonance (bandpass) filters of subthreshold voltage signals. Both filters favor signals in the theta (3-12 Hz) frequency range, but have opposite location, direction, and voltage dependencies: (1) dendritic H-resonance, caused by h/HCN-channels, filters signals propagating from soma to dendrite when the membrane potential is close to rest; and (2) somatic M-resonance, caused by M/Kv7/KCNQ and persistent Na(+) (NaP) channels, filters signals propagating from dendrite to soma when the membrane potential approaches spike threshold. Hippocampal pyramidal cells participate in theta network oscillations during behavior, and we suggest that that these dual, polarized theta resonance mechanisms may convey voltage-dependent tuning of theta-mediated neural coding in the entorhinal/hippocampal system during locomotion, spatial navigation, memory, and sleep.
Structural and Optical Behaviour of Ar+ Implanted Polycarbonate
NASA Astrophysics Data System (ADS)
Shekhawat, Nidhi; Aggarwal, Sanjeev; Sharma, Annu; Deshpande, S. K.; Nair, K. G. M.
2011-07-01
Effects of 130 keV Ar+ ion implantation on the structural and optical properties of polycarbonate specimens have been studied using Raman, UV-Visible spectroscopy and glancing angle X-ray diffraction techniques. Formation of disordered carbonaceous network in the implanted layers has been observed using Raman and UV-Visible spectroscopy. A sharp decline in band gap values (4.1 eV to 0.63 eV) with increase in implantation dose has been observed. This decrease in optical band gap has been correlated with the formation of disordered structures in the implanted layers of polycarbonate.
Innocentini, Murilo D M; Rodrigues, Vanessa P; Romano, Roberto C O; Pileggi, Rafael G; Silva, Gracinda M C; Coury, José R
2009-02-15
Porous ceramic samples were prepared from aqueous foam incorporated alumina suspension for application as hot aerosol filtering membrane. The procedure for establishment of membrane features required to maintain a desired flow condition was theoretically described and experimental work was designed to prepare ceramic membranes to meet the predicted criteria. Two best membranes, thus prepared, were selected for permeability tests up to 700 degrees C and their total and fractional collection efficiencies were experimentally evaluated. Reasonably good performance was achieved at room temperature, while at 700 degrees C, increased permeability was obtained with significant reduction in collection efficiency, which was explained by a combination of thermal expansion of the structure and changes in the gas properties.
NASA Astrophysics Data System (ADS)
Srivastava, A.; Srivastava, O. N.; Talapatra, S.; Vajtai, R.; Ajayan, P. M.
2004-09-01
Over the past decade of nanotube research, a variety of organized nanotube architectures have been fabricated using chemical vapour deposition. The idea of using nanotube structures in separation technology has been proposed, but building macroscopic structures that have controlled geometric shapes, density and dimensions for specific applications still remains a challenge. Here we report the fabrication of freestanding monolithic uniform macroscopic hollow cylinders having radially aligned carbon nanotube walls, with diameters and lengths up to several centimetres. These cylindrical membranes are used as filters to demonstrate their utility in two important settings: the elimination of multiple components of heavy hydrocarbons from petroleum-a crucial step in post-distillation of crude oil-with a single-step filtering process, and the filtration of bacterial contaminants such as Escherichia coli or the nanometre-sized poliovirus (~25 nm) from water. These macro filters can be cleaned for repeated filtration through ultrasonication and autoclaving. The exceptional thermal and mechanical stability of nanotubes, and the high surface area, ease and cost-effective fabrication of the nanotube membranes may allow them to compete with ceramic- and polymer-based separation membranes used commercially.
Srivastava, A; Srivastava, O N; Talapatra, S; Vajtai, R; Ajayan, P M
2004-09-01
Over the past decade of nanotube research, a variety of organized nanotube architectures have been fabricated using chemical vapour deposition. The idea of using nanotube structures in separation technology has been proposed, but building macroscopic structures that have controlled geometric shapes, density and dimensions for specific applications still remains a challenge. Here we report the fabrication of freestanding monolithic uniform macroscopic hollow cylinders having radially aligned carbon nanotube walls, with diameters and lengths up to several centimetres. These cylindrical membranes are used as filters to demonstrate their utility in two important settings: the elimination of multiple components of heavy hydrocarbons from petroleum-a crucial step in post-distillation of crude oil-with a single-step filtering process, and the filtration of bacterial contaminants such as Escherichia coli or the nanometre-sized poliovirus ( approximately 25 nm) from water. These macro filters can be cleaned for repeated filtration through ultrasonication and autoclaving. The exceptional thermal and mechanical stability of nanotubes, and the high surface area, ease and cost-effective fabrication of the nanotube membranes may allow them to compete with ceramic- and polymer-based separation membranes used commercially.
Field Studies Measuring the aerosolization of Endotoxin ...
Endotoxin is a component of the cell walls of Gram-negative bacteria and is known to be present in biosolids. Endotoxins have been shown to be a potent stimulator of the innate immune response causing airway irritation and shortness of breath. Class B biosolids are routinely applied to agricultural lands in the US to enhance soil properties and can be used as an alternative to chemical fertilizers. This study investigated the aerosolized endotoxin produced during the land application of Class B biosolids from various wastewater treatment plants on agricultural land and a concrete surface at two sites in Colorado, USA. Aerosolized endotoxin was captured using HiVol sampler fitted with glass fiber filter, polycarbonate filter cassette (both open and closed), and BioSampler impinger air samplers. Endotoxins were also measured in the bulk biosolids to allow for correlating bulk biosolids concentrations with aerosol emission rates. Endotoxin concentrations in biosolids, impinger solutions, and filter extracts were determined using the kinetic Limulus amebocyte lysate assay. Aerosolized endotoxin concentration was detected from all sites with levels ranging from 0.5 to 642 EU/m3. The four types of sampling apparatus were compared and the HiVol and open-faced cassette samplers used produced higher TWA measurements (EU/m3) than the impinger and closed cassette samplers. Ambient wind speed at the sites was found to be the variable best describing the results wit
21 CFR 177.1580 - Polycarbonate resins.
Code of Federal Regulations, 2014 CFR
2014-04-01
... tested shall be ground or cut into small particles that will pass through a U.S. standard sieve No. 6 and that will be held on a U.S. standard sieve No. 10. (i) Polycarbonate resins, when extracted with...
Thomas, Anthony W; Dove, Andrew P
2016-12-01
Functional aliphatic polycarbonates have attracted significant attention as materials for use as biomedical polymers in recent years. The incorporation of pendent functionality offers a facile method of modifying materials postpolymerization, thus enabling functionalities not compatible with ring-opening polymerization (ROP) to be introduced into the polymer. In particular, polycarbonates bearing alkene-terminated functional groups have generated considerable interest as a result of their ease of synthesis, and the wide range of materials that can be obtained by performing simple postpolymerization modifications on this functionality, for example, through radical thiol-ene addition, Michael addition, and epoxidation reactions. This review presents an in-depth appraisal of the methods used to modify alkene-functional polycarbonates postpolymerization, and the diversity of practical applications for which these materials and their derivatives have been used. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Long-term Calibration Considerations during Subcutaneous Microdialysis Sampling in Mobile Rats
Mou, Xiaodun; Lennartz, Michelle; Loegering, Daniel J.; Stenken, Julie A.
2010-01-01
The level at which implanted sensors and sampling devices maintain their calibration is an important research area. In this work, microdialysis probes with identical geometry and different membranes, polycarbonate/polyether (PC) or polyethersulfone (PES), were used with internal standards (vitamin B12 (MW 1355), antipyrine (MW 188) and 2-deoxyglucose (2-DG, MW 164)) and endogenous glucose to investigate changes in their long-term calibration after implantation into the subcutaneous space of Sprague-Dawley rats. Histological analysis confirmed an inflammatory response to the microdialysis probes and the presence of a collagen capsule. The membrane extraction efficiency (percentage delivered to the tissue space) for antipyrine and 2-DG was not altered throughout the implant lifetime for either PC- or PES-membranes. Yet, Vitamin B12 extraction efficiency and collected glucose concentrations decreased during the implant lifetime. Antipyrine was administered i.v. and its concentrations obtained in both PC-and PES-membrane probes were significantly reduced between the implant day and seven (PC) or 10 (PES) days post implantation suggesting that solute supply is critical for in vivo extraction efficiency. For the low molecular weight solutes such as antipyrine and glucose, localized delivery is not affected by the foreign body reaction, but recovery is significantly reduced. For Vitamin B12, a larger solute, the fibrotic capsule formed around the probe significantly restricts diffusion from the implanted microdialysis probes. PMID:20223515
Polo, Andrea; Foladori, Paola; Ponti, Benedetta; Bettinetti, Roberta; Gambino, Michela; Villa, Federica; Cappitelli, Francesca
2014-01-01
This study provides data to define an efficient biocide-free strategy based on zosteric acid to counteract biofilm formation on the membranes of submerged bioreactor system plants. 16S rRNA gene phylogenetic analysis showed that gammaproteobacteria was the prevalent taxa on fouled membranes of an Italian wastewater plant. Pseudomonas was the prevalent genus among the cultivable membrane-fouler bacteria and Pseudomonas putida was selected as the target microorganism to test the efficacy of the antifoulant. Zosteric acid was not a source of carbon and energy for P. putida cells and, at 200 mg/L, it caused a reduction of bacterial coverage by 80%. Biofilm experiments confirmed the compound caused a significant decrease in biomass (−97%) and thickness (−50%), and it induced a migration activity of the peritrichous flagellated P. putida over the polycarbonate surface not amenable to a biofilm phenotype. The low octanol-water partitioning coefficient and the high water solubility suggested a low bioaccumulation potential and the water compartment as its main environmental recipient and capacitor. Preliminary ecotoxicological tests did not highlight direct toxicity effects toward Daphnia magna. For green algae Pseudokirchneriella subcapitata an effect was observed at concentrations above 100 mg/L with a significant growth of protozoa that may be connected to a concurrent algal growth inhibition. PMID:24879523
Hasegawa, Yuya; Suzuki, Yasutada; Kawakubo, Susumu
2017-01-01
An on-site determination method for trace arsenic has been developed by collecting it as molybdenum blue (MB) in the presence of tetradecyldimethylbenzylammonium chloride on a mixed cellulose ester membrane filter and by measuring reflection absorbance (RA) of MB on the filter using a laboratory-made palm-top size reflection-absorbance colorimeter with a red light-emitting diode. The value of RA was proportional to the amount of arsenic up to 0.5 μg with a detection limit of 0.01 μg. The proposed method was successfully applied to soil extract and hot-spring water samples.
Gunatilake, Udara Bimendra; Bandara, Jayasundera
2017-04-15
For the effective oil/water separation, a novel superhydrophilic (underwater superoleophobic) filter is fabricated with the naturally and hydrothermally treated mica particles. To fabricate a double layered filter, hydrothermally treated mica particles were initially electrodeposited on a stainless steel mesh and a natural mica particles were sprayed on the first hydrothermally deposited mica layer. The double layered mica coated membrane showed superamphiphilic and superhydrophilic/superoleophobic (contact angle >159°) characteristics in air and underwater respectively. The membrane can separate range of oil-water mixtures with oil/water separation efficiency over ∼99%. Properties of double layered mica membrane were investigated and noted that the surface adhesion properties of mica is enhanced by the hydrothermal treatment of mica and the higher roughness of the mica layer is maintained by the natural mica. Copyright © 2017 Elsevier Ltd. All rights reserved.
Detecting a single molecule using a micropore-nanopore hybrid chip
2013-01-01
Nanopore-based DNA sequencing and biomolecule sensing have attracted more and more attention. In this work, novel sensing devices were built on the basis of the chips containing nanopore arrays in polycarbonate (PC) membranes and micropores in Si3N4 films. Using the integrated chips, the transmembrane ionic current induced by biomolecule's translocation was recorded and analyzed, which suggested that the detected current did not change linearly as commonly expected with increasing biomolecule concentration. On the other hand, detailed translocation information (such as translocation gesture) was also extracted from the discrete current blockages in basic current curves. These results indicated that the nanofluidic device based on the chips integrated by micropores and nanopores possessed comparative potentials in biomolecule sensing. PMID:24261484
Detecting a single molecule using a micropore-nanopore hybrid chip.
Liu, Lei; Zhu, Lizhong; Ni, Zhonghua; Chen, Yunfei
2013-11-21
Nanopore-based DNA sequencing and biomolecule sensing have attracted more and more attention. In this work, novel sensing devices were built on the basis of the chips containing nanopore arrays in polycarbonate (PC) membranes and micropores in Si3N4 films. Using the integrated chips, the transmembrane ionic current induced by biomolecule's translocation was recorded and analyzed, which suggested that the detected current did not change linearly as commonly expected with increasing biomolecule concentration. On the other hand, detailed translocation information (such as translocation gesture) was also extracted from the discrete current blockages in basic current curves. These results indicated that the nanofluidic device based on the chips integrated by micropores and nanopores possessed comparative potentials in biomolecule sensing.
Synthesis of high aspect ratio ZnO nanowires with an inexpensive handcrafted electrochemical setup
DOE Office of Scientific and Technical Information (OSTI.GOV)
Taheri, Ali, E-mail: at1361@aut.ac.ir, E-mail: atahery@aeoi.org.ir; Saramad, Shahyar; Setayeshi, Saeed
In this work, high aspect ratio zinc oxide nanowires are synthesized using templated one-step electrodeposition technique. Electrodeposition of the nanowires is done using a handcrafted electronic system. Nuclear track-etched polycarbonate membrane is used as a template to form the high aspect ratio nanowires. The result of X-ray diffraction and scanning electron microscopy shows that nanowires with a good crystallinity and an aspect ratio of more than 30 can be achieved in a suitable condition. The height of electrodeposited nanowires reaches to about 11 μm. Based on the obtained results, high aspect ratio ZnO nanowires can be formed using inexpensive electrodepositionmore » setup with an acceptable quality.« less
Li, Na; Hu, Yi; Lu, Yong-Ze; Zeng, Raymond J; Sheng, Guo-Ping
2016-07-01
In the recent years, anaerobic membrane bioreactor (AnMBR) technology is being considered as a very attractive alternative for wastewater treatment due to the striking advantages such as upgraded effluent quality. However, fouling control is still a problem for the application of AnMBR. This study investigated the performance of an AnMBR using mesh filter as support material to treat low-strength wastewater via in-situ biogas sparging. It was found that mesh AnMBR exhibited high and stable chemical oxygen demand (COD) removal efficiencies with values of 95 ± 5 % and an average methane yield of 0.24 L CH4/g CODremoved. Variation of transmembrane pressure (TMP) during operation indicated that mesh fouling was mitigated by in-situ biogas sparging and the fouling rate was comparable to that of aerobic membrane bioreactor with mesh filter reported in previous researches. The fouling layer formed on the mesh exhibited non-uniform structure; the porosity became larger from bottom layer to top layer. Biogas sparging could not change the composition but make thinner thickness of cake layer, which might be benefit for reducing membrane fouling rate. It was also found that ultrasonic cleaning of fouled mesh was able to remove most foulants on the surface or pores. This study demonstrated that in-situ biogas sparging enhanced the performance of AnMBRs with mesh filter in low-strength wastewater treatment. Apparently, AnMBRs with mesh filter can be used as a promising and sustainable technology for wastewater treatment.
Block Copolymer Membranes for Efficient Capture of a Chemotherapy Drug
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chen, X. Chelsea; Oh, Hee Jeung; Yu, Jay F.
In this paper, we introduce the use of block copolymer membranes for an emerging application, “drug capture”. The polymer is incorporated in a new class of biomedical devices, referred to as ChemoFilter, which is an image-guided temporarily deployable endovascular device designed to increase the efficacy of chemotherapy-based cancer treatment. We show that block copolymer membranes consisting of functional sulfonated polystyrene end blocks and a structural polyethylene middle block (SSES) are capable of capturing doxorubicin, a chemotherapy drug. We focus on the relationship between morphology of the membrane in the ChemoFilter device and efficacy of doxorubicin capture measured in vitro. Usingmore » small-angle X-ray scattering and cryogenic scanning transmission electron microscopy, we discovered that rapid doxorubicin capture is associated with the presence of water-rich channels in the lamellar-forming S-SES membranes in aqueous environment.« less
Block Copolymer Membranes for Efficient Capture of a Chemotherapy Drug
Chen, X. Chelsea; Oh, Hee Jeung; Yu, Jay F.; ...
2016-07-23
In this paper, we introduce the use of block copolymer membranes for an emerging application, “drug capture”. The polymer is incorporated in a new class of biomedical devices, referred to as ChemoFilter, which is an image-guided temporarily deployable endovascular device designed to increase the efficacy of chemotherapy-based cancer treatment. We show that block copolymer membranes consisting of functional sulfonated polystyrene end blocks and a structural polyethylene middle block (SSES) are capable of capturing doxorubicin, a chemotherapy drug. We focus on the relationship between morphology of the membrane in the ChemoFilter device and efficacy of doxorubicin capture measured in vitro. Usingmore » small-angle X-ray scattering and cryogenic scanning transmission electron microscopy, we discovered that rapid doxorubicin capture is associated with the presence of water-rich channels in the lamellar-forming S-SES membranes in aqueous environment.« less
Mechanical properties of injection-molded thermoplastic denture base resins.
Hamanaka, Ippei; Takahashi, Yutaka; Shimizu, Hiroshi
2011-03-01
To investigate the mechanical properties of injection-molded thermoplastic denture base resins. Four injection-molded thermoplastic resins (two polyamides, one polyethylene terephthalate, one polycarbonate) and, as a control, a conventional heat-polymerized polymethyl methacrylate (PMMA), were used in this study. The flexural strength at the proportional limit (FS-PL), the elastic modulus, and the Charpy impact strength of the denture base resins were measured according to International Organization for Standardization (ISO) 1567 and ISO 1567:1999/Amd 1:2003. The descending order of the FS-PL was: conventional PMMA > polyethylene terephthalate, polycarbonate > two polyamides. The descending order of the elastic moduli was: conventional PMMA > polycarbonate > polyethylene terephthalate > two polyamides. The descending order of the Charpy impact strength was: polyamide (Nylon PACM12) > polycarbonate > polyamide (Nylon 12), polyethylene terephthalate > conventional PMMA. All of the injection-molded thermoplastic resins had significantly lower FS-PL, lower elastic moduli, and higher or similar impact strength compared to the conventional PMMA. The polyamide denture base resins had low FS-PL and low elastic moduli; one of them possessed very high impact strength, and the other had low impact strength. The polyethylene terephthalate denture base resin showed a moderately high FS-PL, moderate elastic modulus, and low impact strength. The polycarbonate denture base resin had a moderately high FS-PL, moderately high elastic modulus, and moderate impact strength.
Non-porous membrane-assisted liquid-liquid extraction of UV filter compounds from water samples.
Rodil, Rosario; Schrader, Steffi; Moeder, Monika
2009-06-12
A method for the determination of nine UV filter compounds [benzophenone-3 (BP-3), isoamyl methoxycinnamate, 4-methylbenzylidene camphor, octocrylene (OC), butyl methoxydibenzoylmethane, ethylhexyl dimethyl p-aminobenzoate (OD-PABA), ethylhexyl methoxycinnamate (EHMC), ethylhexyl salicylate and homosalate] in water samples was developed and evaluated. The procedure includes non-porous membrane-assisted liquid-liquid extraction (MALLE) and LC-atmospheric pressure photoionization (APPI)-MS/MS. Membrane bags made of different polymeric materials were examined to enable a fast and simple extraction of the target analytes. Among the polymeric materials tested, low- and high-density polyethylene membranes proved to be well suited to adsorb the analytes from water samples. Finally, 2 cm length tailor-made membrane bags were prepared from low-density polyethylene in order to accommodate 100 microL of propanol. The fully optimised protocol provides recoveries from 76% to 101% and limits of detection (LOD) between 0.4 ng L(-1) (OD-PABA) and 16 ng L(-1) (EHMC). The interday repeatability of the whole protocol was below 18%. The effective separation of matrix molecules was proved by only marginal matrix influence during the APPI-MS analysis since no ion suppression effects were observed. During the extraction step, the influence of the matrix was only significant when non-treated wastewater was analysed. The analysis of lake water indicated the presence of seven UV filter compounds included in this study at concentrations between 40 ng L(-1) (BP-3) and 4381 ng L(-1) (OC). In non-treated wastewater several UV filters were also detected at concentration levels as high as 5322 ng L(-1) (OC).
A method for improving the drop test performance of a MEMS microphone
NASA Astrophysics Data System (ADS)
Winter, Matthias; Ben Aoun, Seifeddine; Feiertag, Gregor; Leidl, Anton; Scheele, Patrick; Seidel, Helmut
2009-05-01
Most micro electro mechanical system (MEMS) microphones are designed as capacitive microphones where a thin conductive membrane is located in front of a rigid counter electrode. The membrane is exposed to the environment to convert sound into vibrations of the membrane. The movement of the membrane causes a change in the capacitance between the membrane and the counter electrode. The resonance frequency of the membrane is designed to occur above the acoustic spectrum to achieve a linear frequency response. To obtain a good sensitivity the thickness of the membrane must be as small as possible, typically below 0.5 μm. These fragile membranes may be damaged by rapid pressure changes. For cell phones, drop tests are among the most relevant reliability tests. The extremely high acceleration during the drop impact leads to fast pressure changes in the microphone which could result in a rupture of the membrane. To overcome this problem a stable protection layer can be placed at a small distance to the membrane. The protective layer has small holes to form a low pass filter for air pressure. The low pass filter reduces pressure changes at high frequencies so that damage to the membrane by excitation in resonance will be prevented.
CFD modeling of catheter-based Chemofilter device for filtering chemotherapy drugs from venous flow
NASA Astrophysics Data System (ADS)
Maani, Nazanin; Yee, Daryl; Nosonovsky, Michael; Greer, Julia; Hetts, Steven; Rayz, Vitaliy
2017-11-01
Purpose: Intra-arterial chemotherapy, a procedure where drugs are injected into arteries supplying a tumor, may cause systemic toxicity. The Chemofilter device, deployed in a vein downstream of the tumor, can chemically filter the excessive drugs from the circulation. In our study, CFD modeling of blood flow through the Chemofilter is used to optimize its hemodynamic performance. Methods:The Chemofilter consists of a porous membrane attached to a stent-like frame of the RX Accunet distal protection filters used for capturing blood clots. The membrane is formed by a lattice of symmetric micro-cells. This design provides a large surface area for the drug binding, and allows blood cells to pass through the lattice. A two-scale modeling approach is used, where the flow through individual micro-cells is simulated to determine the lattice permeability and then the entire device is modeled as a porous membrane. Results: The simulations detected regions of flow stagnation and recirculation caused by the membrane and its supporting frame. The effect of the membrane's leading angle on the velocity and pressure fields was determined. The device optimization will help the efficacy of drug absorption, while the risk of blood clotting reduces. NIH NCI R01CA194533.
Lee, K; Ruby, E G
1995-01-01
To achieve functional bioluminescence, the developing light organ of newly hatched juveniles of the Hawaiian squid Euprymna scolopes must become colonized by luminous, symbiosis-competent Vibrio fischeri present in the ambient seawater. This benign infection occurs rapidly in animals placed in seawater from the host's natural habitat. Therefore, it was surprising that colony hybridization studies with a V. fischeri-specific luxA gene probe indicated the presence of only about 2 CFU of V. fischeri per ml of this infective seawater. To examine this paradox, we estimated the total concentration of V. fischeri cells present in seawater from the host's habitat in two additional ways. In the first approach, the total bacterial assemblage in samples of seawater was collected on polycarbonate membrane filters and used as a source of both a crude cell lysate and purified DNA. These preparations were then assayed by quantitative DNA-DNA hybridization with the luxA gene probe. The results suggested the presence of between 200 and 400 cells of V. fischeri per ml of natural seawater, a concentration more than 100 times that revealed by colony hybridization. In the second approach, we amplified V. fischeri-specific luxA sequences from microliter volumes of natural seawater by PCR. Most-probable-number analyses of the frequency of positive PCR results from cell lysates in these small volumes gave an estimate of the concentration of V. fischeri luxA gene targets of between 130 and 1,680 copies per ml. From these measurements, we conclude that in their natural seawater environment, the majority of V. fischeri cells become nonculturable while remaining viable and symbiotically infective. Experimental studies indicated that V. fischeri cells suspended in natural Hawaiian seawater enter such a state within a few days.
Preparation of pure microbiological samples for pyrolysis gas-liquid chromatography studies
NASA Technical Reports Server (NTRS)
Oxborrow, G. S.; Fields, N. D.; Puleo, J. R.
1976-01-01
Bacterial samples were prepared for pyrolysis gas-liquid chromatography using cells grown on membrane filters. Pyrochromatograms were reproducible when cells harvested from the filters were pyrolyzed without being washed.
Hall, G.E.M.; Bonham-Carter, G. F.; Horowitz, A.J.; Lum, K.; Lemieux, C.; Quemerais, B.; Garbarino, J.R.
1996-01-01
The effect of 4 different 0.45 ??m pore size filter membrane systems on the 'dissolved' concentration of 28 elements in 5 natural water samples of varying matrix is reported. In 3 of the 5 waters, consistently higher concentrations of most elements (minor and trace) are obtained using Nucleopore 47 mm filter and the cellulose acetate/nitrate 47 mm filter than those measured using the 142 mm cellulose nitrate MFS filter or the Gelman capsule 47 mm filter. These distinct and coherent patterns in elemental behaviour disappear for the other 2 samples, an organic-rich peat water of high suspended load and a mineralised sample high in Si and Ca. Thus the nature and degree of filtration artifacts is matrix-dependent. These trends are evident in both data sets produced by 2 independent laboratories using different instrumentation, techniques and calibrating procedures. The average relative standard deviation in elemental concentration across the 4 filter types is in the range 9-21%. The presence of such filtration artifacts must be considered in projects where, for example, seasonal variability of water composition is under examination, data from various sources are being merged or hydrogeochemical surveys are being conducted.
Fan, Xinfei; Zhao, Huimin; Quan, Xie; Liu, Yanming; Chen, Shuo
2016-01-01
Membrane filtration provides an effective solution for removing pollutants from water but is limited by serious membrane fouling. In this work, an effective approach was used to mitigate membrane fouling by integrating membrane filtration with electropolarization using an electroconductive nanocarbon-based membrane. The electropolarized membrane (EM) by alternating square-wave potentials between +1.0 V and -1.0 V with a pulse width of 60 s exhibited a permeate flux 8.1 times as high as that without electropolarization for filtering feed water containing bacteria, which confirms the ability of the EM to achieve biofouling mitigation. Moreover, the permeate flux of EM was 1.5 times as high as that without electropolarization when filtrating natural organic matter (NOM) from water, and demonstrated good performance in organic fouling mitigation with EM. Furthermore, the EM was also effective for complex fouling mitigation in filtering water containing coexisting bacteria and NOM, and presented an increased flux rate 1.9 times as high as that without electropolarization. The superior fouling mitigation performance of EM was attributed to the synergistic effects of electrostatic repulsion, electrochemical oxidation and electrokinetic behaviors. This work opens an effective avenue for membrane fouling mitigation of water-treatment membrane filtration systems. Copyright © 2015 Elsevier Ltd. All rights reserved.
Amphiphobic Polytetrafluoroethylene Membranes for Efficient Organic Aerosol Removal.
Feng, Shasha; Zhong, Zhaoxiang; Zhang, Feng; Wang, Yong; Xing, Weihong
2016-04-06
Polytetrafluoroethylene (PTFE) membrane is an extensively used air filter, but its oleophilicity leads to severe fouling of the membrane surface due to organic aerosol deposition. Herein, we report the fabrication of a new amphiphobic 1H,1H,2H,2H-perfluorodecyl acrylate (PFDAE)-grafted ZnO@PTFE membrane with enhanced antifouling functionality and high removal efficiency. We use atomic-layer deposition (ALD) to uniformly coat a layer of nanosized ZnO particles onto porous PTFE matrix to increase surface area and then subsequently graft PFDAE with plasma. Consequently, the membrane surface showed both superhydrophobicity and oleophobicity with a water contact angle (WCA) and an oil contact angle (OCA) of 150° and 125°, respectively. The membrane air permeation rate of 513 (m(3) m(-2) h(-1) kPa(-1)) was lower than the pristine membrane rate of 550 (m(3) m(-2) h(-1) kPa(-1)), which indicates the surface modification slightly decreased the membrane air permeation. Significantly, the filtration resistance of this amphiphobic membrane to the oil aerosol system was much lower than the initial one. Moreover, the filter exhibited exceptional organic aerosol removal efficiencies that were greater than 99.5%. These results make the amphiphobic PTFE membranes very promising for organic aerosol-laden air-filtration applications.
NASA Technical Reports Server (NTRS)
Kourtides, D. A.; Parker, J. A.; Hilado, C. J.
1977-01-01
The thermochemical and flammability characteristics of some typical thermoplastic materials currently in use or being considered for use in aircraft interiors are described. The properties studied included thermomechanical properties such as glass-transition and melt temperature, changes in polymer enthalpy, thermogravimetric analysis in anerobic and oxidative environments, oxygen index, smoke evolution, relative toxicity of the volatile products of pyrolysis, and selected physical properties. The generic polymers evaluated included acrylonitrile butadiene styrene, bisphenol A polycarbonate, 9,9 bis (4-hydroxyphenyl) fluorene polycarbonate-poly (dimethylsiloxane) block polymer, phenolphthalein-bisphenol A polycarbonate, phenolphthalein polycarbonate, polyether sulfone, polyphenylene oxide, polyphenylene sulfide, polyaryl sulfone, chlorinated polyvinyl chloride homopolymer, polyvinyl fluoride, and polyvinylidene fluoride. Processing parameters, including molding characteristics of some of the advanced polymers, are described. Test results and relative rankings of some of the flammability, smoke, and toxicity properties are presented. Under these test conditions, some of the advanced polymers evaluated were significantly less flammable and toxic than or equivalent to polymers in current use.
Demirkol, Guler Turkoglu; Dizge, Nadir; Acar, Turkan Ormanci; Salmanli, Oyku Mutlu; Tufekci, Nese
2017-07-01
In this study, polyethersulfone (PES) ultrafiltration membrane surface was modified with nano-sized zinc oxide (nZnO) and silver (nAg) to improve the membrane filterability of the mixed liquor and used to treat fruit-juice industry wastewater in a submerged membrane bioreactor (MBR). The nAg was synthesized using three different methods. In the first method, named as nAg-M1, PES membrane was placed on the membrane module and nAg solution was passed through the membrane for 24 h at 25 ± 1 °C. In the second method, named as nAg-M2, PES membrane was placed in a glass container and it was shaken for 24 h at 150 rpm at 25 ± 1 °C. In the third method, named as nAg-M3, Ag nanoparticles were loaded onto PES membrane in L-ascorbic acid solution (0.1 mol/L) at pH 2 for 24 h at 150 rpm at 25 ± 1 °C. For the preparation of nZnO coated membrane, nZnO nanoparticles solution was passed through the membrane for 24 h at 25 ± 1 °C. Anti-fouling performance of pristine and coated membranes was examined using the submerged MBR. The results showed that nZnO and nAg-M3 membranes showed lower flux decline compared with pristine membrane. Moreover, pristine and coated PES membranes were characterized using a permeation test, contact angle goniometer, and scanning electron microscopy.
Rotating carbon nanotube membrane filter for water desalination
NASA Astrophysics Data System (ADS)
Tu, Qingsong; Yang, Qiang; Wang, Hualin; Li, Shaofan
2016-05-01
We have designed a porous nanofluidic desalination device, a rotating carbon nanotube membrane filter (RCNT-MF), for the reverse osmosis desalination that can turn salt water into fresh water. The concept as well as design strategy of RCNT-MF is modeled, and demonstrated by using molecular dynamics simulation. It has been shown that the RCNT-MF device may significantly improve desalination efficiency by combining the centrifugal force propelled reverse osmosis process and the porous CNT-based fine scale selective separation technology.
2015-03-24
were made via filtration of 1 mL of 1 mg/L SWCNT solution (Nanointegris Inc.) through a 20 nm pore anodized aluminum oxide ( AAO ) membrane filter to...prepared by attaching a rectangular piece cut from the AAO membrane filter onto a glass substrate. Contacts were made with silver paste to the extremities...NUMBER(S) 14. ABSTRACT _ The development of high TCR materials, such as vanadium oxide (VOx), has enabled the introduction of bolometric infrared
Rotating carbon nanotube membrane filter for water desalination
Tu, Qingsong; Yang, Qiang; Wang, Hualin; Li, Shaofan
2016-01-01
We have designed a porous nanofluidic desalination device, a rotating carbon nanotube membrane filter (RCNT-MF), for the reverse osmosis desalination that can turn salt water into fresh water. The concept as well as design strategy of RCNT-MF is modeled, and demonstrated by using molecular dynamics simulation. It has been shown that the RCNT-MF device may significantly improve desalination efficiency by combining the centrifugal force propelled reverse osmosis process and the porous CNT-based fine scale selective separation technology. PMID:27188982
Selective Nanoscale Mass Transport across Atomically Thin Single Crystalline Graphene Membranes.
Kidambi, Piran R; Boutilier, Michael S H; Wang, Luda; Jang, Doojoon; Kim, Jeehwan; Karnik, Rohit
2017-05-01
Atomically thin single crystals, without grain boundaries and associated defect clusters, represent ideal systems to study and understand intrinsic defects in materials, but probing them collectively over large area remains nontrivial. In this study, the authors probe nanoscale mass transport across large-area (≈0.2 cm 2 ) single-crystalline graphene membranes. A novel, polymer-free picture frame assisted technique, coupled with a stress-inducing nickel layer is used to transfer single crystalline graphene grown on silicon carbide substrates to flexible polycarbonate track etched supports with well-defined cylindrical ≈200 nm pores. Diffusion-driven flow shows selective transport of ≈0.66 nm hydrated K + and Cl - ions over ≈1 nm sized small molecules, indicating the presence of selective sub-nanometer to nanometer sized defects. This work presents a framework to test the barrier properties and intrinsic quality of atomically thin materials at the sub-nanometer to nanometer scale over technologically relevant large areas, and suggests the potential use of intrinsic defects in atomically thin materials for molecular separations or desalting. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
NASA Astrophysics Data System (ADS)
Muench, Falk; Oezaslan, Mehtap; Svoboda, Ingrid; Ensinger, Wolfgang
2015-10-01
We present new electroless palladium plating reactions, which can be applied to complex-shaped substrates and lead to homogeneous, dense and conformal palladium films consisting of small nanoparticles. Notably, autocatalytic and surface-selective metal deposition could be achieved on a wide range of materials without sensitization and activation pretreatments. This provides a facile and competitive route to directly deposit well-defined palladium nanofilms on e.g. carbon, paper, polymers or glass substrates. The reactions proceed at mild conditions and are based on easily accessible chemicals (reducing agent: hydrazine; metal source: PdCl2; ligands: ethylenediaminetetraacetic acid (EDTA), acetylacetone). Additionally, the water-soluble capping agent 4-dimethylaminopyridine (DMAP) is employed to increase the bath stability, to ensure the formation of small particles and to improve the film conformity. The great potential of the outlined reactions for micro- and nanofabrication is demonstrated by coating an ion-track etched polycarbonate membrane with a uniform Pd film of approximately 20 nm thickness. The as-prepared membrane is then employed as a highly miniaturized flow reactor, using the reduction of 4-nitrophenol with NaBH4 as a model reaction.
Zhang, Jin; Agramunt-Puig, Sebastià; Del-Valle, Núria; Navau, Carles; Baró, Maria D; Estradé, Sònia; Peiró, Francesca; Pané, Salvador; Nelson, Bradley J; Sanchez, Alvaro; Nogués, Josep; Pellicer, Eva; Sort, Jordi
2016-02-17
A new strategy to minimize magnetic interactions between nanowires (NWs) dispersed in a fluid is proposed. Such a strategy consists of preparing trisegmented NWs containing two antiparallel ferromagnetic segments with dissimilar coercivity separated by a nonmagnetic spacer. The trisegmented NWs exhibit a staircase-like hysteresis loop with tunable shape that depends on the relative length of the soft- and hard-magnetic segments and the respective values of saturation magnetization. Such NWs are prepared by electrodepositing CoPt/Cu/Ni in a polycarbonate (PC) membrane. The antiparallel alignment is set by applying suitable magnetic fields while the NWs are still embedded in the PC membrane. Analytic calculations are used to demonstrate that the interaction magnetic energy from fully compensated trisegmented NWs with antiparallel alignment is reduced compared to a single-component NW with the same length or the trisegmented NWs with the two ferromagnetic counterparts parallel to each other. The proposed approach is appealing for the use of magnetic NWs in certain biological or catalytic applications where the aggregation of NWs is detrimental for optimized performance.
Template Synthesis of Nanostructured Polymeric Membranes by Inkjet Printing.
Gao, Peng; Hunter, Aaron; Benavides, Sherwood; Summe, Mark J; Gao, Feng; Phillip, William A
2016-02-10
The fabrication of functional nanomaterials with complex structures has been serving great scientific and practical interests, but current fabrication and patterning methods are generally costly and laborious. Here, we introduce a versatile, reliable, and rapid method for fabricating nanostructured polymeric materials. The novel method is based on a combination of inkjet printing and template synthesis, and its utility and advantages in the fabrication of polymeric nanomaterials is demonstrated through three examples: the generation of polymeric nanotubes, nanowires, and thin films. Layer-by-layer-assembled nanotubes can be synthesized in a polycarbonate track-etched (PCTE) membrane by printing poly(allylamine hydrochloride) and poly(styrenesulfonate) sequentially. This sequential deposition of polyelectrolyte ink enables control over the surface charge within the nanotubes. By a simple change of the printing conditions, polymeric nanotubes or nanowires were prepared by printing poly(vinyl alcohol) in a PCTE template. In this case, the high-throughput nature of the method enables functional nanomaterials to be generated in under 3 min. Furthermore, we demonstrate that inkjet printing paired with template synthesis can be used to generate patterns comprised of chemically distinct nanomaterials. Thin polymeric films of layer-by-layer-assembled poly(allylamine hydrochloride) and poly(styrenesulfonate) are printed on a PCTE membrane. Track-etched membranes covered with the deposited thin films reject ions and can potentially be utilized as nanofiltration membranes. When the fabrication of these different classes of nanostructured materials is demonstrated, the advantages of pairing template synthesis with inkjet printing, which include fast and reliable deposition, judicious use of the deposited materials, and the ability to design chemically patterned surfaces, are highlighted.
Replacement of filters for respirable quartz measurement in coal mine dust by infrared spectroscopy.
Farcas, Daniel; Lee, Taekhee; Chisholm, William P; Soo, Jhy-Charm; Harper, Martin
2016-01-01
The objective of this article is to compare and characterize nylon, polypropylene (PP), and polyvinyl chloride (PVC) membrane filters that might be used to replace the vinyl/acrylic co-polymer (DM-450) filter currently used in the Mine Safety and Health Administration (MSHA) P-7 method (Quartz Analytical Method) and the National Institute for Occupational Safety and Health (NIOSH) Manual of Analytical Methods 7603 method (QUARTZ in coal mine dust, by IR re-deposition). This effort is necessary because the DM-450 filters are no longer commercially available. There is an impending shortage of DM-450 filters. For example, the MSHA Pittsburgh laboratory alone analyzes annually approximately 15,000 samples according to the MSHA P-7 method that requires DM-450 filters. Membrane filters suitable for on-filter analysis should have high infrared (IR) transmittance in the spectral region 600-1000 cm(-1). Nylon (47 mm, 0.45 µm pore size), PP (47 mm, 0.45 µm pore size), and PVC (47 mm, 5 µm pore size) filters meet this specification. Limits of detection and limits of quantification were determined from Fourier transform infrared spectroscopy (FTIR) measurements of blank filters. The average measured quartz mass and coefficient of variation were determined from test filters spiked with respirable α-quartz following MSHA P-7 and NIOSH 7603 methods. Quartz was also quantified in samples of respirable coal dust on each test filter type using the MSHA and NIOSH analysis methods. The results indicate that PP and PVC filters may replace the DM-450 filters for quartz measurement in coal dust by FTIR. PVC filters of 5 µm pore size seemed to be suitable replacement although their ability to retain small particulates should be checked by further experiment.
Rhodopsin-lipid interactions studied by NMR.
Soubias, Olivier; Gawrisch, Klaus
2013-01-01
The biophysical properties of the lipid matrix are known to influence function of integral membrane proteins. We report on a sample preparation method for reconstitution of membrane proteins which uses porous anodic aluminum oxide (AAO) filters with 200-nm-wide pores of high density. The substrate permits formation of tubular, single membranes that line the inner surface of pores. One square centimeter of filter with a thickness of 60μm yields on the order of 500cm(2) of solid-supported single bilayer surface, sufficient for NMR studies. The tubular bilayers are free of detergent, fully hydrated, and accessible for ligands from one side of the membrane. The use of AAO filters greatly improves reproducibility of the reconstitution process such that the influence of protein on lipid order parameters can be studied with high resolution. As an example, results for the G protein-coupled receptor of class A, bovine rhodopsin, are shown. By (2)H NMR order parameter measurements, it is detected that rhodopsin insertion elastically deforms membranes near the protein. Furthermore, by (1)H saturation-transfer NMR under conditions of magic angle spinning, we demonstrate detection of preferences in interactions of rhodopsin with particular lipid species. It is assumed that function of integral membrane proteins depends on both protein-induced elastic deformations of the lipid matrix and preferences for interaction of the protein with particular lipid species in the first layer of lipids surrounding the protein. Copyright © 2013 Elsevier Inc. All rights reserved.
Honeycutt, Jennifer A; Nguyen, Jenny Q T; Kentner, Amanda C; Brenhouse, Heather C
2017-05-01
Bisphenol A (BPA) is widely used in the polycarbonate plastics and epoxy resins that are found in laboratory animal husbandry materials including cages and water bottles. Concerns about BPA exposure in humans has led to investigations that suggest physiologic health risks including disruptions to the endocrine system and CNS. However, the extent of exposure of laboratory animals to BPA in drinking water is unclear. In the first study, we compared the amount of BPA contamination in water stored in plastic bottles used in research settings with that in glass bottles. The amount of BPA that leached into water was measured across several time points ranging from 24 to 96 h by using a BPA ELISA assay. The results showed that considerable amounts of BPA (approximately 0.15 μg/L) leached from polycarbonate bottles within the first 24 h of storage. In the second study, BPA levels were measured directly from water taken from filtered compared with unfiltered taps. We observed significantly higher BPA levels in water from unfiltered taps (approximately 0.40 μg/L) compared with taps with filtration systems (approximately 0.04 μg/L). Taken together, our findings indicate that the use of different types of water bottles and water sources, combined with the use of different laboratory products (food, caging systems) between laboratories, likely contribute to decreased rigor and reproducibility in research. We suggest that researchers consider reporting the types of water bottles used and that animal care facilities educate staff regarding the importance of flushing nonfiltered water taps when filling animal water bottles.
Boonruksa, Pongsit; Bello, Dhimiter; Zhang, Jinde; Isaacs, Jacqueline A; Mead, Joey L; Woskie, Susan R
2017-07-01
In this study, the characteristics of airborne particles generated during injection molding and grinding processes of carbon nanotube reinforced polycarbonate composites (CNT-PC) were investigated. Particle number concentration, size distribution, and morphology of particles emitted from the processes were determined using real-time particle sizers and transmission electron microscopy. The air samples near the operator's breathing zone were collected on filters and analyzed using scanning electron microscope for particle morphology and respirable fiber count. Processing and grinding during recycling of CNT-PC released airborne nanoparticles (NPs) with a geometric mean (GM) particle concentration from 4.7 × 10 3 to 1.7 × 10 6 particles/cm 3 . The ratios of the GM particle concentration measured during the injection molding process with exhaust ventilation relative to background were up to 1.3 (loading), 1.9 (melting), and 1.4 (molding), and 101.4 for grinding process without exhaust ventilation, suggesting substantial NP exposures during these processes. The estimated mass concentration was in the range of 1.6-95.2 μg/m 3 . Diverse particle morphologies, including NPs, NP agglomerates, particles with embedded or protruding CNTs and fibers, were observed. No free CNTs were found during any of the investigated processes. The breathing zone respirable fiber concentration during the grinding process ranged from non-detectable to 0.13 fiber/cm 3 . No evidence was found that the emissions were affected by the number of recycling cycles. Institution of exposure controls is recommended during these processes to limit exposures to airborne NPs and CNT-containing fibers.
Honeycutt, Jennifer A; Nguyen, Jenny Q T; Kentner, Amanda C; Brenhouse, Heather C
2017-01-01
Bisphenol A (BPA) is widely used in the polycarbonate plastics and epoxy resins that are found in laboratory animal husbandry materials including cages and water bottles. Concerns about BPA exposure in humans has led to investigations that suggest physiologic health risks including disruptions to the endocrine system and CNS. However, the extent of exposure of laboratory animals to BPA in drinking water is unclear. In the first study, we compared the amount of BPA contamination in water stored in plastic bottles used in research settings with that in glass bottles. The amount of BPA that leached into water was measured across several time points ranging from 24 to 96 h by using a BPA ELISA assay. The results showed that considerable amounts of BPA (approximately 0.15 μg/L) leached from polycarbonate bottles within the first 24 h of storage. In the second study, BPA levels were measured directly from water taken from filtered compared with unfiltered taps. We observed significantly higher BPA levels in water from unfiltered taps (approximately 0.40 μg/L) compared with taps with filtration systems (approximately 0.04 μg/L). Taken together, our findings indicate that the use of different types of water bottles and water sources, combined with the use of different laboratory products (food, caging systems) between laboratories, likely contribute to decreased rigor and reproducibility in research. We suggest that researchers consider reporting the types of water bottles used and that animal care facilities educate staff regarding the importance of flushing nonfiltered water taps when filling animal water bottles. PMID:28535862
Preparation of lipid nanoemulsions by premix membrane emulsification with disposable materials.
Gehrmann, Sandra; Bunjes, Heike
2016-09-25
The possibility to prepare nanoemulsions as drug carrier systems on small scale was investigated with disposable materials. For this purpose premix membrane emulsification (premix ME) as a preparation method for nanoemulsions with narrow particle size distributions on small scale was used. The basic principle of premix ME is that the droplets of a coarse pre-emulsion get disrupted by the extrusion through a porous membrane. In order to implement the common preparation setup for premix ME with disposable materials, the suitability of different syringe filters (made from polyethersulfone, cellulose acetate, cellulose ester and nylon) and different pharmaceutically relevant emulsifiers (phospholipids, polysorbate 80 and sucrose laurate) for the preparation of nanoemulsions was investigated. Already the preparation of the premix could be realized by emulsification with the help of two disposable syringes. As shown for a phospholipid-stabilized emulsion, the polyethersulfone filter was the most appropriate one and was used for the study with different emulsifiers. With this syringe filter, the median particle size of all investigated emulsions was below 500nm after 21 extrusion cycles through a 200nm filter and a subsequent extrusion cycle through a 100nm filter. Furthermore, the particle size distribution of the polysorbate 80- and sucrose laurate-stabilized emulsions prepared this way was very narrow (span value of 0.7). Copyright © 2016 Elsevier B.V. All rights reserved.
Variation in animal response to different toxicants
NASA Technical Reports Server (NTRS)
Hilado, C. J.; Cumming, H. J.
1977-01-01
The variation in response of different lots of male Swiss albino mice to pyrolysis effluents from surgical cotton and from bisphenol A polycarbonate, and to pure carbon monoxide, is discussed. The variation appeared to be less with the pyrolysis gases from polycarbonate than with pure carbon monoxide.
Conclusions on measurement uncertainty in microbiology.
Forster, Lynne I
2009-01-01
Since its first issue in 1999, testing laboratories wishing to comply with all the requirements of ISO/IEC 17025 have been collecting data for estimating uncertainty of measurement for quantitative determinations. In the microbiological field of testing, some debate has arisen as to whether uncertainty needs to be estimated for each method performed in the laboratory for each type of sample matrix tested. Queries also arise concerning the estimation of uncertainty when plate/membrane filter colony counts are below recommended method counting range limits. A selection of water samples (with low to high contamination) was tested in replicate with the associated uncertainty of measurement being estimated from the analytical results obtained. The analyses performed on the water samples included total coliforms, fecal coliforms, fecal streptococci by membrane filtration, and heterotrophic plate counts by the pour plate technique. For those samples where plate/membrane filter colony counts were > or =20, uncertainty estimates at a 95% confidence level were very similar for the methods, being estimated as 0.13, 0.14, 0.14, and 0.12, respectively. For those samples where plate/membrane filter colony counts were <20, estimated uncertainty values for each sample showed close agreement with published confidence limits established using a Poisson distribution approach.
Lively, Brooks; Kumar, Sandeep; Tian, Liu; Li, Bin; Zhong, Wei-Hong
2011-05-01
In this study we report the advantages of a 2-step method that incorporates an additional process pre-conditioning step for rapid and precise blending of the constituents prior to the commonly used melt compounding method for preparing polycarbonate/oxidized carbon nanofiber composites. This additional step (equivalent to a manufacturing cell) involves the formation of a highly concentrated solid nano-nectar of polycarbonate/carbon nanofiber composite using a solution mixing process followed by melt mixing with pure polycarbonate. This combined method yields excellent dispersion and improved mechanical and thermal properties as compared to the 1-step melt mixing method. The test results indicated that inclusion of carbon nanofibers into composites via the 2-step method resulted in dramatically reduced ( 48% lower) coefficient of thermal expansion compared to that of pure polycarbonate and 30% lower than that from the 1-step processing, at the same loading of 1.0 wt%. Improvements were also found in dynamic mechanical analysis and flexural mechanical properties. The 2-step approach is more precise and leads to better dispersion, higher quality, consistency, and improved performance in critical application areas. It is also consistent with Lean Manufacturing principles in which manufacturing cells are linked together using less of the key resources and creates a smoother production flow. Therefore, this 2-step process can be more attractive for industry.
Preparation of pure microbiological samples for pyrolysis of gas-liquid chromatography studies.
Oxborrow, G S; Fields, N D; Puleo, J R
1976-01-01
Bacterial samples were prepared for pyrolysis gas-liquid chromatography using cells grown on membrane filters. Pyrochromatograms were reproducible when cells harvested from the filters were pyrolyzed without being washed. Images PMID:970947
High-speed water sterilization using silver-containing cellulose membranes
NASA Astrophysics Data System (ADS)
Sinclair, Terica; Zieba, Maciej; Irusta, Silvia; Sebastián, Víctor; Arruebo, Manuel
2014-08-01
The removal of bacteria and other pathogenic micro-organisms from drinking water is usually carried out by boiling; however, when this is not a feasible option, a combination of treatment based on filtration and disinfection is recommended. In this work, we produced cellulose filters grafted with silver nanoparticles (AgNPs) and silver nanowires (AgNWs) by covalent attachment of separately prepared Ag nanostructures on thiol- and amine-modified commercially available cellulosic filters. Results obtained from scanning electron microscopy (SEM), scanning transmission electron microscopy (STEM), and energy-dispersive X-ray spectroscopy (EDS) all revealed that such modified cellulose membranes contained large amounts of homogeneously dispersed AgNPs, whereas X-ray photoelectron spectroscopy (XPS) analysis demonstrated that the aforementioned nanostructures were immobilized on the membrane with a strong and stable covalent bond between the thiol or amine groups and the surface of the Ag nanofillers. This durable and robust covalent attachment facilitated outstanding suppression of the uncontrolled release of the nanostructures from the membranes, even under strong ultrasonication. Those membranes also demonstrated high permeance and antimicrobial activity in excess of 99.9% growth inhibition against Escherichia coli, which was used as a model of gram-negative coliform bacteria. Bacteria percolated throughout the tortuous silver-loaded filters, thus increasing the chances of contact between the Ag nanostructures (wires or nanoparticles) and the passing bacteria. Thus, we anticipate that these filters, with their high antibacterial activity and robustness, can be produced in a cost-effective manner and that they would be capable of producing affordable, clean, and safe drinking water in a short period of time without producing an uncontrolled silver release into the percolated water.
Dishari, Shudipto K; Venkiteshwaran, Adith; Zydney, Andrew L
2015-10-01
Virus filtration is used to ensure drug safety in the production of biotherapeutics. Several recent studies have shown a dramatic decrease in virus retention as a result of a process disruption, e.g., a transient pressure release. In this work, a novel two-label fluorescence technique was developed to probe virus capture within virus filtration membranes using confocal microscopy. Experiments were performed with Ultipor® DV20, Viresolve® Pro, and Viresolve® NFP membranes using bacteriophage φx174 as a model virus. The filters were challenged with two batches of fluorescently labeled phage: one labeled with red dye (Cy5) and one with green dye (SYBR Gold) to visualize captured phage from before and after the pressure release. The capture patterns seen in the confocal images were a strong function of the underlying membrane morphology and pore structure. The DV20 and Viresolve® NFP showed migration of previously captured phage further into the filter, consistent with the observed loss of virus retention after the pressure release. In contrast, there was no migration of captured virus in the Viresolve® Pro membranes, and these filters were also the only ones to show stable virus retention after a pressure release. The direct visualization of virus capture using the two-label fluorescence technique provides unique insights into the factors controlling the retention characteristics of virus filters with different pore structure. © 2015 Wiley Periodicals, Inc.
Code of Federal Regulations, 2014 CFR
2014-07-01
... metal and not have a compartment exceeding ten (10) feet in length. Glass or polycarbonate materials... polycarbonate windows and lenses shall not exceed 115 °C (240 °F), in normal operation. Other non-metallic... metallic conduit are not permitted. (H) Unused lead entrances shall be closed with a metal plug that is...
Code of Federal Regulations, 2010 CFR
2010-07-01
... metal and not have a compartment exceeding ten (10) feet in length. Glass or polycarbonate materials... polycarbonate windows and lenses shall not exceed 115 °C (240 °F), in normal operation. Other non-metallic... metallic conduit are not permitted. (H) Unused lead entrances shall be closed with a metal plug that is...
Code of Federal Regulations, 2011 CFR
2011-07-01
... metal and not have a compartment exceeding ten (10) feet in length. Glass or polycarbonate materials... polycarbonate windows and lenses shall not exceed 115 °C (240 °F), in normal operation. Other non-metallic... metallic conduit are not permitted. (H) Unused lead entrances shall be closed with a metal plug that is...
Code of Federal Regulations, 2013 CFR
2013-07-01
... metal and not have a compartment exceeding ten (10) feet in length. Glass or polycarbonate materials... polycarbonate windows and lenses shall not exceed 115 °C (240 °F), in normal operation. Other non-metallic... metallic conduit are not permitted. (H) Unused lead entrances shall be closed with a metal plug that is...
Code of Federal Regulations, 2012 CFR
2012-07-01
... metal and not have a compartment exceeding ten (10) feet in length. Glass or polycarbonate materials... polycarbonate windows and lenses shall not exceed 115 °C (240 °F), in normal operation. Other non-metallic... metallic conduit are not permitted. (H) Unused lead entrances shall be closed with a metal plug that is...
Antistatic Polycarbonate/Copper Oxide Composite
NASA Technical Reports Server (NTRS)
Kovich, Michael; Rowland, George R., Jr.
2003-01-01
A composite material consisting of polycarbonate filled with copper oxide has been found to be suitable as an antistatic material. This material was developed to satisfy a requirement for an antistatic material that has a mass density less than that of aluminum and that exhibits an acceptably low level of outgassing in a vacuum.
2013-11-18
the experimental filter media Next-SandTM was used, thus turbidity results may not be translatable to conventional filtration media. The media...performance objective was not met. Further optimization of the media filtration process would result in meeting the objective. Dissolved Organic Carbon...FINAL REPORT Perchlorate Destruction and Potable Water Production Using Membrane Biofilm Reduction and Membrane Filtration ESTCP Project ER
Parylene as a new membrane material for BioMEMS applications
NASA Astrophysics Data System (ADS)
Lu, Bo
The work in this thesis aims to use MEMS and microfabrication technologies to develop two types of parylene membrane devices for biomedical applications. The first device is the parylene membrane filter for cancer detection. The presence of circulating tumor cells (CTC) in patient blood is an important sign of cancer metastasis. However, currently there are two big challenges for CTC detection. First, CTCs are extremely rare, especially at the early stage of cancer metastasis. Secondly, CTCs are very fragile, and are very likely to be damaged during the capturing process. By using size-based membrane filtration through the specially designed parylene filters, together with a constant-pressure filtration system, we are able to capture the CTCs from patient blood with high capture efficiency, high viability, moderate enrichment, and high throughput. Both immunofluorescence enumeration and telomerase activity detection have been used to detect and differentiate the captured CTCs. The feasibility of further cell culture of the captured CTCs has also been demonstrated, which could be a useful way to increase the number of CTCs for future studies. Models of the time-dependent cell membrane damage are developed to predict and prevent CTC damage during this detection process. The results of clinical trials further demonstrate that the parylene membrane filter is a promising device for cancer detection. The second device is the parylene artificial Bruch's membrane for age-related macular degeneration (AMD). AMD is usually characterized by an impaired Bruch's membrane with much lowered permeability, which impedes the transportation of nutrients from choroid vessels to nourish the retinal pigment epithelial (RPE) cells and photoreceptors. Parylene is selected as a substitute material because of its good mechanical properties, transparency, biocompatibility, and machinability. More importantly, it is found that the permeability of submicron parylene is very similar to that of healthy human Bruch's membrane. A mesh-supported submicron parylene membrane structure has been designed and its feasibility as an artificial Bruch's membrane has been demonstrated by diffusion experiments, cell perfusion culture, and pressure deflection tests. RPE cells are able to adhere, proliferate and develop into normal in vivo-like morphology and functions. Currently this artificial membrane is under clinical trials.
Microfluidic "Pouch" Chips for Immunoassays and Nucleic Acid Amplification Tests.
Mauk, Michael G; Liu, Changchun; Qiu, Xianbo; Chen, Dafeng; Song, Jinzhao; Bau, Haim H
2017-01-01
Microfluidic cassettes ("chips") for processing and analysis of clinical specimens and other sample types facilitate point-of-care (POC) immunoassays and nucleic acid based amplification tests. These single-use test chips can be self-contained and made amenable to autonomous operation-reducing or eliminating supporting instrumentation-by incorporating laminated, pliable "pouch" and membrane structures for fluid storage, pumping, mixing, and flow control. Materials and methods for integrating flexible pouch compartments and diaphragm valves into hard plastic (e.g., acrylic and polycarbonate) microfluidic "chips" for reagent storage, fluid actuation, and flow control are described. We review several versions of these pouch chips for immunoassay and nucleic acid amplification tests, and describe related fabrication techniques. These protocols thus offer a "toolbox" of methods for storage, pumping, and flow control functions in microfluidic devices.
Francis, Mark Rohit; Sarkar, Rajiv; Roy, Sheela; Jaffar, Shabbar; Mohan, Venkata Raghava; Kang, Gagandeep; Balraj, Vinohar
2016-11-02
Since point-of-use methods of water filtration have shown limited acceptance in Vellore, southern India, this study evaluated the effectiveness of decentralized membrane filtration 1) with safe storage, 2) without safe storage, versus 3) no intervention, consisting of central chlorination as per government guidelines, in improving the microbiological quality of drinking water and preventing childhood diarrhea. Periodic testing of water sources, pre-/postfiltration samples, and household water, and a biweekly follow up of children less than 2 years of age was done for 1 year. The membrane filters achieved a log reduction of 0.86 (0.69-1.06), 1.14 (0.99-1.30), and 0.79 (0.67-0.94) for total coliforms, fecal coliforms, and Escherichia coli, respectively, in field conditions. A 24% (incidence rate ratio, IRR [95% confidence interval, CI] = 0.76 [0.51-1.13]; P = 0.178) reduction in diarrheal incidence in the intervention village with safe storage and a 14% (IRR [95% CI] = 1.14 [0.75-1.77]; P = 0.530) increase in incidence for the intervention village without safe storage versus no intervention village was observed, although not statistically significant. Microbiologically, the membrane filters decreased fecal contamination; however, provision of decentralized membrane-filtered water with or without safe storage was not protective against childhood diarrhea. © The American Society of Tropical Medicine and Hygiene.
Francis, Mark Rohit; Sarkar, Rajiv; Roy, Sheela; Jaffar, Shabbar; Mohan, Venkata Raghava; Kang, Gagandeep; Balraj, Vinohar
2016-01-01
Since point-of-use methods of water filtration have shown limited acceptance in Vellore, southern India, this study evaluated the effectiveness of decentralized membrane filtration 1) with safe storage, 2) without safe storage, versus 3) no intervention, consisting of central chlorination as per government guidelines, in improving the microbiological quality of drinking water and preventing childhood diarrhea. Periodic testing of water sources, pre-/postfiltration samples, and household water, and a biweekly follow up of children less than 2 years of age was done for 1 year. The membrane filters achieved a log reduction of 0.86 (0.69–1.06), 1.14 (0.99–1.30), and 0.79 (0.67–0.94) for total coliforms, fecal coliforms, and Escherichia coli, respectively, in field conditions. A 24% (incidence rate ratio, IRR [95% confidence interval, CI] = 0.76 [0.51–1.13]; P = 0.178) reduction in diarrheal incidence in the intervention village with safe storage and a 14% (IRR [95% CI] = 1.14 [0.75–1.77]; P = 0.530) increase in incidence for the intervention village without safe storage versus no intervention village was observed, although not statistically significant. Microbiologically, the membrane filters decreased fecal contamination; however, provision of decentralized membrane-filtered water with or without safe storage was not protective against childhood diarrhea. PMID:27601525
A RAPID, SPECIFIC MEMBRANE FILTRATION PROCEDURE FOR ENUMERATION OF ENTEROCOCCI IN RECREATIONAL WATER
A two-step membrane filter (MP) method with mE medium, upon which the membrane must be incubated for 48 h and then transferred to a substrate medium to differentiate enterococci, is recommended by the U.S.Environmental Protection Agency to measure enterococci in fresh and marine ...
Tobin, R S; Lomax, P; Kushner, D J
1980-01-01
Nine different brands of membrane filter were compared in the membrane filtration (MF) method, and those with the highest yields were compared against the most-probable-number (MPN) multiple-tube method for total coliform enumeration in simulated sewage-contaminated tap water. The water was chlorinated for 30 min to subject the organisms to stresses similar to those encountered during treatment and distribution of drinking water. Significant differences were observed among membranes in four of the six experiments, with two- to four-times-higher recoveries between the membranes at each extreme of recovery. When results from the membranes with the highest total coliform recovery rate were compared with the MPN results, the MF results were found significantly higher in one experiment and equivalent to the MPN results in the other five experiments. A comparison was made of the species enumerated by these methods; in general the two methods enumerated a similar spectrum of organisms, with some indication that the MF method was subject to greater interference by Aeromonas. PMID:7469407
Pugia, Michael; Magbanua, Mark Jesus M; Park, John W
2017-01-01
Isolation by size using a filter membrane offers an antigen-independent method for capturing rare cells present in blood of cancer patients. Multiple cell types, including circulating tumor cells (CTCs), captured on the filter membrane can be simultaneously identified via immunocytochemistry (ICC) analysis of specific cellular biomarkers. Here, we describe an automated microfluidic filtration method combined with a liquid handling system for sequential ICC assays to detect and enumerate non-hematologic rare cells in blood.
Adhesive compositions and methods
DOE Office of Scientific and Technical Information (OSTI.GOV)
Allen, Scott D.; Sendijarevic, Vahid; O'Connor, James
The present invention encompasses polyurethane adhesive compositions comprising aliphatic polycarbonate chains. In one aspect, the present invention encompasses polyurethane adhesives derived from aliphatic polycarbonate polyols and polyisocyanates wherein the polyol chains contain a primary repeating unit having a structure:. In another aspect, the invention provides articles comprising the inventive polyurethane compositions as well as methods of making such compositions.
Modeling Plastic Shocks in Periodic Laminates with Gradient Plasticity Theories
2007-08-26
stainless steel (SS)) layers with volume fractions being respectively, LLf /11= , LLf /22= . (3) Material characteristics of the...characteristics of polycarbonate and stainless steel Poisson ratio Elastic shear modulus Mass density PC...Polycarbonate) 0.37 0.94 Gpa 1190 kg/m3 SS ( Stainless steel ) 0.29 77 Gpa 7890 kg
Reproducibility of polycarbonate reference material in toxicity evaluation
NASA Technical Reports Server (NTRS)
Hilado, C. J.; Huttlinger, P. A.
1981-01-01
A specific lot of bisphenol A polycarbonate has been used for almost four years as the reference material for the NASA-USF-PSC toxicity screening test method. The reproducibility of the test results over this period of time indicate that certain plastics may be more suitable reference materials than the more traditional cellulosic materials.
Polycarbonates: a long-term highly sensitive radon monitor
NASA Astrophysics Data System (ADS)
Pressyanov, D.; Buysse, J.; Poffijn, A.; Meesen, G.; Van Deynse, A.
2000-06-01
An approach for long-term (either retrospective or prospective) 222Rn measurements is proposed that is based on the combination of the high radon absorption ability of some polycarbonates with their alpha track-etch properties. The detection limit is projected to be <10 Bq m -3 for an exposure time of 20 yr.
Learn about the NESHAP for GMACT for acetal resins, hydrogen fluoride, polycarbonate, ethylene production and cyanide chemicals. Find the rule history information, federal register citations, legal authority, rule summary, and additional resources
Biosensors Based on Ultrathin Film Composite Membranes
1994-01-25
composite membranes should have a number C •’ of potential advantages including fast response time, simplicity of construction, and applicability to a number...The support membrane for the ultrathin film composite was an Anopore ( Alltech Associates) microporous alumina filter, these membranes are 55 Pm thick...constant 02 concentration in this solution. Finally, one of the most important potential advantage of a sensor based on an ultrathin film composite
Calculation of airborne radioactivity in a Technegas lung ventilation unit.
López Medina, A; Miñano, J A; Terrón, J A; Bullejos, J A; Guerrero, R; Arroyo, T; Ramírez, A; Llamas, J M
1999-12-01
Airborne contamination by 99Tcm has been monitored in the Nuclear Medicine Department in our hospital to assess the risk of internal contamination to occupational workers exposed to Technegas studies. An air sampler fitted with a membrane filter was used. The optimum time for air absorption for obtaining the maximum activity in the filter was calculated. Maximum activity in the membrane filter ensures minimum uncertainty, which is especially important when low-level activities are being measured. The optimum time depends on air absorption velocity, room volume and filter efficiency for isotope collection. It tends to 1/lambda (lambda = disintegration constant for 99Tcm) for large volume and low velocity. Room activity with the air pump switched on was related to filter activity, and its variation with time was studied. Free activity in air for each study was approximately 7 x 10(-4) the activity used, and the effective half-life of the isotope in the room was 13.9 min (decay and diffusion). For a typical study (630 MBq), the effective dose to staff was 0.01 microSv when in the room for 10 min.
Crystal Structure of an Ammonia-Permeable Aquaporin
Kirscht, Andreas; Kaptan, Shreyas S.; Bienert, Gerd Patrick; Chaumont, François; Nissen, Poul; de Groot, Bert L.; Kjellbom, Per; Gourdon, Pontus; Johanson, Urban
2016-01-01
Aquaporins of the TIP subfamily (Tonoplast Intrinsic Proteins) have been suggested to facilitate permeation of water and ammonia across the vacuolar membrane of plants, allowing the vacuole to efficiently sequester ammonium ions and counteract cytosolic fluctuations of ammonia. Here, we report the structure determined at 1.18 Å resolution from twinned crystals of Arabidopsis thaliana aquaporin AtTIP2;1 and confirm water and ammonia permeability of the purified protein reconstituted in proteoliposomes as further substantiated by molecular dynamics simulations. The structure of AtTIP2;1 reveals an extended selectivity filter with the conserved arginine of the filter adopting a unique unpredicted position. The relatively wide pore and the polar nature of the selectivity filter clarify the ammonia permeability. By mutational studies, we show that the identified determinants in the extended selectivity filter region are sufficient to convert a strictly water-specific human aquaporin into an AtTIP2;1-like ammonia channel. A flexible histidine and a novel water-filled side pore are speculated to deprotonate ammonium ions, thereby possibly increasing permeation of ammonia. The molecular understanding of how aquaporins facilitate ammonia flux across membranes could potentially be used to modulate ammonia losses over the plasma membrane to the atmosphere, e.g., during photorespiration, and thereby to modify the nitrogen use efficiency of plants. PMID:27028365
Rotating Reverse-Osmosis for Water Purification
NASA Technical Reports Server (NTRS)
Lueptow, RIchard M.
2004-01-01
A new design for a water-filtering device combines rotating filtration with reverse osmosis to create a rotating reverse- osmosis system. Rotating filtration has been used for separating plasma from whole blood, while reverse osmosis has been used in purification of water and in some chemical processes. Reverse- osmosis membranes are vulnerable to concentration polarization a type of fouling in which the chemicals meant not to pass through the reverse-osmosis membranes accumulate very near the surfaces of the membranes. The combination of rotating filtration and reverse osmosis is intended to prevent concentration polarization and thereby increase the desired flux of filtered water while decreasing the likelihood of passage of undesired chemical species through the filter. Devices based on this concept could be useful in a variety of commercial applications, including purification and desalination of drinking water, purification of pharmaceutical process water, treatment of household and industrial wastewater, and treatment of industrial process water. A rotating filter consists of a cylindrical porous microfilter rotating within a stationary concentric cylindrical outer shell (see figure). The aqueous suspension enters one end of the annulus between the inner and outer cylinders. Filtrate passes through the rotating cylindrical microfilter and is removed via a hollow shaft. The concentrated suspension is removed at the end of the annulus opposite the end where the suspension entered.
A new method for isolation of polyethylene wear debris from tissue and synovial fluid.
Visentin, Manuela; Stea, Susanna; Squarzoni, Stefano; Antonietti, Barbara; Reggiani, Matteo; Toni, Aldo
2004-11-01
Sub-micron-sized ultrahigh molecular-weight polyethylene (PE) debris is generated in the joint space as a result of articulation and cyclic loading of an orthopaedic implant. Its characterization requires isolation and subsequent analysis by ultra-structural methods. An innovative method based on the digestion of paraffin-embedded tissue samples was proposed. Tissue slices were digested with sodium hypochlorite directly on polycarbonate filter. The same procedure could be applied also to fresh synovial fluid. Plastic particles were not lost or damaged during treatment. Chemical identification of particles was done by micro-Raman spectroscopy that confirmed purity of retrieved PE particles. Size and shape of PE particles were characterised using scanning electron microscopy and were comparable in number and morphology to the retrieval by other authors. Equivalent diameter ranged from 0.48 to 0.95microm and particle number ranged from 9 to 23x10(9)/cm(3).
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dewani, Aliya A., E-mail: a.ashraf@griffith.edu.au; O’Keefe, Steven G.; Thiel, David V.
A novel 2D simple low cost frequency selective surface was screen printed on thin (0.21 mm), flexible transparent plastic substrate (relative permittivity 3.2). It was designed, fabricated and tested in the frequency range 10-20 GHz. The plane wave transmission and reflection coefficients agreed with numerical modelling. The effective permittivity and thickness of the backing sheet has a significant effect on the frequency characteristics. The stop band frequency reduced from 15GHz (no backing) to 12.5GHz with polycarbonate. The plastic substrate thickness beyond 1.8mm has minimal effect on the resonant frequency. While the inner element spacing controls the stop-band frequency, the substratemore » thickness controls the bandwidth. The screen printing technique provided a simple, low cost FSS fabrication method to produce flexible, conformal, optically transparent and bio-degradable FSS structures which can find their use in electromagnetic shielding and filtering applications in radomes, reflector antennas, beam splitters and polarizers.« less
Optically transparent frequency selective surfaces on flexible thin plastic substrates
NASA Astrophysics Data System (ADS)
Dewani, Aliya A.; O'Keefe, Steven G.; Thiel, David V.; Galehdar, Amir
2015-02-01
A novel 2D simple low cost frequency selective surface was screen printed on thin (0.21 mm), flexible transparent plastic substrate (relative permittivity 3.2). It was designed, fabricated and tested in the frequency range 10-20 GHz. The plane wave transmission and reflection coefficients agreed with numerical modelling. The effective permittivity and thickness of the backing sheet has a significant effect on the frequency characteristics. The stop band frequency reduced from 15GHz (no backing) to 12.5GHz with polycarbonate. The plastic substrate thickness beyond 1.8mm has minimal effect on the resonant frequency. While the inner element spacing controls the stop-band frequency, the substrate thickness controls the bandwidth. The screen printing technique provided a simple, low cost FSS fabrication method to produce flexible, conformal, optically transparent and bio-degradable FSS structures which can find their use in electromagnetic shielding and filtering applications in radomes, reflector antennas, beam splitters and polarizers.
Separation membrane development
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lee, M.W.
1998-08-01
A ceramic membrane has been developed to separate hydrogen from other gases. The method used is a sol-gel process. A thin layer of dense ceramic material is coated on a coarse ceramic filter substrate. The pore size distribution in the thin layer is controlled by a densification of the coating materials by heat treatment. The membrane has been tested by permeation measurement of the hydrogen and other gases. Selectivity of the membrane has been achieved to separate hydrogen from carbon monoxide. The permeation rate of hydrogen through the ceramic membrane was about 20 times larger than Pd-Ag membrane.
1986-10-01
consists of two near-hemispheric shells bolted to a mounted plate housing the sampling system. Its walls are anodized black to decrease 13 surface...a distinct advantage when the test aerosol contains a significant quantity of liquid. Membrane filters tend to load and reduce throughout while...Table 6. As indicated, these filters can be estremely efficient. Should absolute retention be required, the AAO grade filter with a pore size of 0.3
Williams, Margaret M; Chen, Tai-Ho; Keane, Tim; Toney, Nadege; Toney, Sean; Armbruster, Catherine R; Butler, W Ray; Arduino, Matthew J
2011-09-01
Healthcare-associated outbreaks and pseudo-outbreaks of rapidly growing mycobacteria (RGM) are frequently associated with contaminated tap water. A pseudo-outbreak of Mycobacterium chelonae-M. abscessus in patients undergoing bronchoscopy was identified by 2 acute care hospitals. RGM was identified in bronchoscopy specimens of 28 patients, 25 of whom resided in the same skilled nursing facility (SNF). An investigation ruled out bronchoscopy procedures, specimen collection, and scope reprocessing at the hospitals as sources of transmission. To identify the reservoir for RGM within the SNF and evaluate 2 water system treatments, hyperchlorination and point-of-use (POU) membrane filters, to reduce RGM. A comparative in situ study of 2 water system treatments to prevent RGM transmission. An SNF specializing in care of patients requiring ventilator support. RGM and heterotrophic plate count (HPC) bacteria were examined in facility water before and after hyperchlorination and in a subsequent 24-week assessment of filtered water by colony enumeration on Middlebrook and R2A media. Mycobacterium chelonae was consistently isolated from the SNF water supply. Hyperchlorination reduced RGM by 1.5 log(10) initially, but the population returned to original levels within 90 days. Concentration of HPC bacteria also decreased temporarily. RGM were reduced below detection level in filtered water, a 3-log(10) reduction. HPC bacteria were not recovered from newly installed filters, although low quantities were found in water from 2-week-old filters. POU membrane filters may be a feasible prevention measure for healthcare facilities to limit exposure of sensitive individuals to RGM in potable water systems.
ERIC Educational Resources Information Center
Chan, Julian M. W.; Zhang, Xiangyi; Brennan, Megan K.; Sardon, Haritz; Engler, Amanda C.; Fox, Courtney H.; Frank, Curtis W.; Waymouth, Robert M.; Hedrick, James L.
2015-01-01
In this laboratory experiment, students work in pairs to synthesize a simple aliphatic polycarbonate via ring-opening polymerization of trimethylene carbonate using 1,8-diazabicyclo[5.4.0]undec-7-ene and thiourea as organocatalysts. Following polymer isolation, students cool the material in a dry ice/acetone bath to observe its glass-transition…
Abdallah, Marwan; Chataigne, Gabrielle; Ferreira-Theret, Pauline; Benoliel, Corinne; Drider, Djamel; Dhulster, Pascal; Chihib, Nour-Eddine
2014-03-01
The goal of this study was to investigate the effect of the environmental conditions such as the temperature change, incubation time and surface type on the resistance of Staphylococcus aureus biofilms to disinfectants. The antibiofilm assays were performed against biofilms grown at 20 °C, 30 °C and 37 °C, on the stainless steel and polycarbonate, during 24 and 48 h. The involvement of the biofilm matrix and the bacterial membrane fluidity in the resistance of sessile cells were investigated. Our results show that the efficiency of disinfectants was dependent on the growth temperature, the surface type and the disinfectant product. The increase of growth temperature from 20 °C to 37 °C, with an incubation time of 24 h, increased the resistance of biofilms to cationic antimicrobials. This change of growth temperature did not affect the major content of the biofilm matrix, but it decreased the membrane fluidity of sessile cells through the increase of the anteiso-C19 relative amount. The increase of the biofilm resistance to disinfectants, with the rise of the incubation time, was dependent on both growth temperature and disinfectant product. The increase of the biofilm age also promoted increases in the matrix production and the membrane fluidity of sessile cells. The resistance of S. aureus biofilm seems to depend on the environment of the biofilm formation and involves both extracellular matrix and membrane fluidity of sessile cells. Our study represents the first report describing the impact of environmental conditions on the matrix production, sessile cells membrane fluidity and resistance of S. aureus biofilms to disinfectants.
Navarro, Marta; Benito, Javier; Paseta, Lorena; Gascón, Ignacio; Coronas, Joaquín; Téllez, Carlos
2018-01-10
An innovative procedure for positioning a monolayer of hydrophilic metal organic framework (MOF) MIL-101(Cr) (MIL, Materials of Institute Lavoisier) nanoparticles (NPs) in thin-film nanocomposite (TFN) membranes has been implemented by transferring a Langmuir-Schaefer (LS) film of the MOF in between the polyamide thin layer at the top and the cross-linked asymmetric polyimide (P84) support at the bottom. The presence and layout of the LS-MIL-101(Cr) monolayer in the TFN membrane was confirmed by scanning transmission electron microscopy imaging with a high-angle annular dark-field detector images and X-ray photoelectron spectroscopy, energy-dispersive X-ray spectroscopy, electron energy loss spectroscopy, and atomic force microscopy analyses. This methodology requires the smallest amount of MOF reported to date, 3.8 μg cm -2 , and promotes the formation of a defect-free ultrathin MOF film. Although conventional TFN membranes tend to show MOF agglomerates that could contribute to the formation of unselective defects, LS-TFN membranes, characterized by a homogeneous and continuous MOF coating, exhibit an optimal membrane performance, without a significant decrease in selectivity. Outstanding methanol permeances, one of the best results reported to date, of 10.1 ± 0.5 L m -2 h -1 bar -1 when filtering sunset yellow and of 9.5 ± 2.1 L m -2 h -1 bar -1 when filtering rose bengal have been achieved in LS-TFN membranes with a rejection higher than 90% in all cases. Methanol permeates through the polyamide and the LS-MIL-101(Cr) monolayer, greatly enhanced by the MOF pore system, in comparison to thin-film composite and conventional TFN membranes (7.5 ± 0.7 and 7.7 ± 1.1 L m -2 h -1 bar -1 when filtering sunset yellow), respectively, in which polyamide areas free of MOF NPs are present.
Membrane water deaerator investigation. [fluid filter breadboard model
NASA Technical Reports Server (NTRS)
Elam, J.; Ruder, J.; Strumpf, H.
1974-01-01
The purpose of the membrane water deaerator program was to develop data on a breadboard hollow fiber membrane unit that removes both dissolved and evolved gas from a water transfer system in order to: (1) assure a hard fill of the EVLSS expendable water tank; (2) prevent flow blockage by gas bubbles in circulating systems; and (3) prevent pump cavitation.
Frère, Antoine; Baroni, Alexandra; Hendrick, Elodie; Delvigne, Anne-Sophie; Orange, François; Peulen, Olivier; Dakwar, George R; Diricq, Jérôme; Dubois, Philippe; Evrard, Brigitte; Remaut, Katrien; Braeckmans, Kevin; De Smedt, Stefaan C; Laloy, Julie; Dogné, Jean-Michel; Feller, Georges; Mespouille, Laetitia; Mottet, Denis; Piel, Géraldine
2017-01-25
Guanidine and morpholine functionalized aliphatic polycarbonate polymers are able to deliver efficiently histone deacetylase 5 (HDAC5) siRNA into the cytoplasm of cancer cells in vitro leading to a decrease of cell proliferation were previously developed. To allow these biodegradable and biocompatible polyplex nanoparticles to overcome the extracellular barriers and be effective in vivo after an intravenous injection, polyethylene glycol chains (PEG 750 or PEG 2000 ) were grafted on the polymer structure. These nanoparticles showed an average size of about 150 nm and a slightly positive ζ-potential with complete siRNA complexation. Behavior of PEGylated and non-PEGylated polyplexes were investigated in the presence of serum, in terms of siRNA complexation (fluorescence correlation spectroscopy), size (dynamic light scattering and single-particle tracking), interaction with proteins (isothermal titration calorimetry) and cellular uptake. Surprisingly, both PEGylated and non-PEGylated formulations presented relatively good behavior in the presence of fetal bovine serum (FBS). Hemocompatibility tests showed no effect of these polyplexes on hemolysis and coagulation. In vivo biodistribution in mice was performed and showed a better siRNA accumulation at the tumor site for PEGylated polyplexes. However, cellular uptake in protein-rich conditions showed that PEGylated polyplex lost their ability to interact with biological membranes and enter into cells, showing the importance to perform in vitro investigations in physiological conditions closed to in vivo situation. In vitro, the efficiency of PEGylated nanoparticles decreases compared to non-PEGylated particles, leading to the loss of the antiproliferative effect on cancer cells.
SiC: filter for extreme ultraviolet
NASA Astrophysics Data System (ADS)
Mitrofanov, Alexander V.; Pudonin, Fedor A.; Zhitnik, Igor A.
1994-09-01
It is proposed to use thin films of silicon carbide as Extreme Ultraviolet bandpass filters transparent within 135-304 A band and with excellent cutoff blocking of the strong L(subscript (alpha) ) 1216 A line radiation. Mesh or particle track porous membrane supporting 200-800 A thickness SiC filters have been made by RF sputtering techniques. We describe the design and performance of these filters. Such type SiC filter was used in front of the microchannel plate detector of the TEREK X-Ray Telescope mounted on the Solar Observatory CORONAS-I which was successfully launched on March 2, 1994.
Moon, Bo Mi; Choi, Myung-Jin; Sultan, Md Tipu; Yang, Jae Won; Ju, Hyung Woo; Lee, Jung Min; Park, Hyun Jung; Park, Ye Ri; Kim, Soo Hyeon; Kim, Dong Wook; Lee, Min Chae; Jeong, Ju Yeon; Lee, Ok Joo; Sung, Gun Yong; Park, Chan Hum
2017-10-01
During the last decade, there has been a great advance in the kidney dialysis system by wearable artificial kidney (WAK) system for end-stage renal disease patients. Uremic solute removal and water regeneration system are the most prerequisite for WAK to work properly. In this study, we designed a filtering membrane system by using immobilized urease silk fibroin filter and evaluated its comparative effectiveness with a PVDF filtering system in peritoneal dialysate regeneration system by urea removal efficacy. We evaluated this membrane's characteristic and performances by conducting SEM-EDX analyze, water-binding abilities and porosity test, removal abilities of urea, cytotoxicity assay and enzyme activity assay. Under the condition for optimization of urease, the percentage removal of urea was about 40% and 60% in 50 mg/dL urea solution by urease immobilized PVDF and silk fibroin scaffolds, respectively. The batch experimental result showed that immobilized filter removed more than 50% of urea in 50 mg/dL urea solution. In addition silk fibroin with urease filter removed 90 percent of urea in the peritoneal dialysate after 24 h filtration. We suggest that silk fibroin with urease fixation filter can be used more effectively for peritoneal dialysate regeneration system, which have hydrophilic property and prolonged enzyme activity. © 2016 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 105B: 2136-2144, 2017. © 2016 Wiley Periodicals, Inc.
Protein Adsorption to In-Line Filters of Intravenous Administration Sets.
Besheer, Ahmed
2017-10-01
Ensuring compatibility of administered therapeutic proteins with intravenous administration sets is an important regulatory requirement. A low-dose recovery during administration of low protein concentrations is among the commonly observed incompatibilities, and it is mainly due to adsorption to in-line filters. To better understand this phenomenon, we studied the adsorption of 4 different therapeutic proteins (2 IgG1s, 1 IgG4, and 1 Fc fusion protein) diluted to 0.01 mg/mL in 5% glucose (B. Braun EcoFlac; B. Braun Melsungen AG, Melsungen, Germany) or 0.9% sodium chloride (NaCl; Freeflex; Fresenius Kabi, Friedberg, Germany) solutions to 8 in-line filters (5 positively charged and 3 neutral filters made of different polymers and by different suppliers). The results show certain patterns of protein adsorption, which depend to a large extent on the dilution solution and filter material, and to a much lower extent on the proteins' biophysical properties. Investigation of the filter membranes' zeta potential showed a correlation between the observed adsorption pattern in 5% glucose solution and the filter's surface charge, with higher protein adsorption for the strongly negatively charged membranes. In 0.9% NaCl solution, the surface charges are masked, leading to different adsorption patterns. These results contribute to the general understanding of the protein adsorption to IV infusion filters and allow the design of more efficient compatibility studies. Copyright © 2017 American Pharmacists Association®. Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Lyon, Richard F.
2011-11-01
A cascade of two-pole-two-zero filters with level-dependent pole and zero dampings, with few parameters, can provide a good match to human psychophysical and physiological data. The model has been fitted to data on detection threshold for tones in notched-noise masking, including bandwidth and filter shape changes over a wide range of levels, and has been shown to provide better fits with fewer parameters compared to other auditory filter models such as gammachirps. Originally motivated as an efficient machine implementation of auditory filtering related to the WKB analysis method of cochlear wave propagation, such filter cascades also provide good fits to mechanical basilar membrane data, and to auditory nerve data, including linear low-frequency tail response, level-dependent peak gain, sharp tuning curves, nonlinear compression curves, level-independent zero-crossing times in the impulse response, realistic instantaneous frequency glides, and appropriate level-dependent group delay even with minimum-phase response. As part of exploring different level-dependent parameterizations of such filter cascades, we have identified a simple sufficient condition for stable zero-crossing times, based on the shifting property of the Laplace transform: simply move all the s-domain poles and zeros by equal amounts in the real-s direction. Such pole-zero filter cascades are efficient front ends for machine hearing applications, such as music information retrieval, content identification, speech recognition, and sound indexing.
New seminal plasma removal method for freezing stallion semen.
Ramires Neto, C; Monteiro, G A; Soares, R F; Pedrazzi, C; Dell'aqua, J A; Papa, F O; Castro-Chaves, M M; Alvarenga, M A
2013-04-15
Seminal plasma removal, an indispensable step in equine semen cryopreservation, is usually done by centrifugation, but this might cause mechanical damage to sperm. A new method for seminal plasma removal from stallion semen, namely a filter composed of a synthetic hydrophilic membrane (Sperm Filter, BotuPharma, Botucatu, Sao Paulo, Brazil), was recently proposed. The objective of this study was to test the use of the Sperm Filter in the removal of seminal plasma before freezing stallion semen. Ejaculates from 31 stallions were divided into two groups and cryopreserved. In group 1 (G1), seminal plasma was removed with the Sperm Filter, and in group 2 (G2), seminal plasma was removed by centrifugation (600×g for 10 minutes). There were no differences (P < 0.05) between G1 and G2 in sperm kinetic parameters or plasma membrane integrity before or after cryopreservation. However, sperm recovery rate was higher (P < 0.05) for G1 versus G2 (mean ± SD, 89.4 ± 7.4% vs. 80.9 ± 5.5%). Therefore, the Sperm Filter was as efficient as centrifugation in removing seminal plasma from the stallion ejaculate. However, filtering was more practical and had significantly fewer sperm lost than the centrifugation technique. Copyright © 2013 Elsevier Inc. All rights reserved.
Polymer compositions and methods
DOE Office of Scientific and Technical Information (OSTI.GOV)
Allen, Scott D.; Willkomm, Wayne R.
The present invention encompasses polyurethane compositions comprising aliphatic polycarbonate chains. In one aspect, the present invention encompasses polyurethane foams, thermoplastics and elastomers derived from aliphatic polycarbonate polyols and polyisocyanates wherein the polyol chains contain a primary repeating unit having a structure: ##STR00001## In another aspect, the invention provides articles comprising the inventive foam and elastomer compositions as well as methods of making such compositions.
Method for the preparation of ferrous low carbon porous material
Miller, Curtis Jack
2014-05-27
A method for preparing a porous metal article using a powder metallurgy forming process is provided which eliminates the conventional steps associated with removing residual carbon. The method uses a feedstock that includes a ferrous metal powder and a polycarbonate binder. The polycarbonate binder can be removed by thermal decomposition after the metal article is formed without leaving a carbon residue.
Polymer compositions and methods
Allen, Scott D.; Willkomm, Wayne R.
2016-09-27
The present invention encompasses polyurethane compositions comprising aliphatic polycarbonate chains. In one aspect, the present invention encompasses polyurethane foams, thermoplastics and elastomers derived from aliphatic polycarbonate polyols and polyisocyanates wherein the polyol chains contain a primary repeating unit having a structure: ##STR00001## In another aspect, the invention provides articles comprising the inventive foam and elastomer compositions as well as methods of making such compositions.
Cole-cole analysis and electrical conduction mechanism of N{sup +} implanted polycarbonate
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chawla, Mahak; Shekhawat, Nidhi; Aggarwal, Sanjeev, E-mail: write2sa@gmail.com
2014-05-14
In this paper, we present the analysis of the dielectric (dielectric constant, dielectric loss, a.c. conductivity) and electrical properties (I–V characteristics) of pristine and nitrogen ion implanted polycarbonate. The samples of polycarbonate were implanted with 100 keV N{sup +} ions with fluence ranging from 1 × 10{sup 15} to 1 × 10{sup 17} ions cm{sup −2}. The dielectric measurements of these samples were performed in the frequency range of 100 kHz to 100 MHz. It has been observed that dielectric constant decreases whereas dielectric loss and a.c. conductivity increases with increasing ion fluence. An analysis of real and imaginary parts of dielectric permittivity has beenmore » elucidated using Cole-Cole plot of the complex permittivity. With the help of Cole-Cole plot, we determined the values of static dielectric constant (ε{sub s}), optical dielectric constant (ε{sub ∞}), spreading factor (α), average relaxation time (τ{sub 0}), and molecular relaxation time (τ). The I–V characteristics were studied using Keithley (6517) electrometer. The electrical conduction behaviour of pristine and implanted polycarbonate specimens has been explained using various models of conduction.« less
Tracking of Polycarbonate Films using Low-energy Ions Final Report CRADA No. TC-774-94
DOE Office of Scientific and Technical Information (OSTI.GOV)
Musket, R. G.
2018-01-24
Ion tracking is performed almost exclusively using ions with energies near or above the maximum in electronic stopping. For the present study, we have examined the results of etching ion tracks created by ions bombarding polycarbonate films with energies corresponding to stopping well below the maximum and just above the anticipated threshold for creating etchable latent tracks. Low-energy neon and argon ions with 18-60 keV /amu and fluences of about 10 8/cm 2 were used to examine the limits for producing etchable tracks in polycarbonate films. By concentrating on the early stages of etching (i.e., -20 nm < SEM holemore » diameter < -100 nm), we can directly relate the energy deposition calculated for the incident ion to the creation of etchable tracks. The experimental results will be discussed with regard to the energy losses of the ions in the polycarbonate films and to the formation of continuous latent tracks through the entire thickness the films. These results have significant implications with respect to the threshold for formation of etchable tracks and to the use of low-energy ions for lithographic applications.« less
Nano filter from sintered rice husk silica membrane.
Lee, Soo Young; Han, Chong Soo
2006-11-01
A nano filter showing the Knudsen flow was demonstrated by a modification of a membrane constructed from rice husk silica. The membrane was prepared by pressing and sintering micron sized rice husk silica with 4 nm pores. The membrane showed a permeability of 5.2 x 10(-8) mol m(-1) sec(-1) Pa(-1) for H2 and ratios of gas permeability 2.1 and 3.2 for k(H2)/k(CH4) and k(H2)/k(CO2), respectively. When the membrane was treated by filtration of approximately 100 nm sized rice husk silica particles, the permeability decreased to 4.9 x 10(-8) mol m(-1) sec(-1) Pa(-1) and the ratios increased to 2.2 and 3.4. In the case of the membrane after treatments with the dispersion and chemical deposition of tetraethylorthosilicate (TEOS), the corresponding permeability and ratios of the membrane were 1.8 x 10(-8) mol m(-1) sec(-1) Pa(-1), and 2.9 and 4.5, respectively. From the change of the ratio of gas permeability for the membrane with modifications, it is suggested that approximately 100 nm sized rice husk silica particles pack the large pores among the micron sized rice husk silica particles while the chemical deposition of tetraethylorthosilicate (TEOS) reveals the gas flow through 4 nm pores in the rice husk silica by blocking large pores.
Sanislo, L; Kuliffay, P; Sedlak, J; Kausitz, J; Galbavy, S
2010-01-01
The aim of our study was the potential detection of circulating tumour cells (CTCs) in early stage breast cancer patients. Our approach was cell microfiltration through polycarbonate membrane as a concentration method suitable for CTC selection in peripheral blood. The isolated cells on membrane were further analysed by laser scanning cytometry. Sixteen patients were enrolled in the study, of which 13 had early stage breast carcinoma and 3 patients had metastatic breast carcinoma. The analyses were performed from 9 ml of peripheral blood, in one patient blood was drawn twice. Blood samples were taken after adjuvant chemotherapy but prior to adjuvant radiotherapy. The control group consisted of 12 clinically healthy subjects. In the control group 3 subjects out of 12 had 1 CTC, the mean CTC numbers being 0.25 +/- 0.45. In the early stage breast cancer patients 0-36 CTCs were detected (mean 13.9 +/- 12.9 CTCs. 10 patients out of 13 had more than 2 CTCs (62%). The detection and measurement of cells on membrane is a simple and reproducible method of detection of CTCs in peripheral blood. Sensitivity of the method is 88.5%. Detection of CTCs seems to be a promising method for the monitoring of adjuvant therapy in early stage breast cancer patients and for the identification of high risk patients in whom elevated numbers of CTCs are persisting following the termination of adjuvant therapy (Tab. 1, Fig. 4, Ref. 35). Full Text (Free, PDF) www.bmj.sk.
Glass cylindrical filter for electrolysis cell
NASA Astrophysics Data System (ADS)
Abe, Shinichi; Akiyama, Fuminori
1992-09-01
Some electrolysis requires separation of electrolytic solution by a filter between two electrodes in order to prevent products from reacting secondarily at another electrode. These filters are usually made of a glass filter or ion exchanger membrane, and they are fixed at the electrolysis cell or cover one electrode. This report presents a detachable glass cylindrical filter for electrolytic reaction. The glass cylindrical filter was made from glass filter powder placed in a mold and heated at 800 C for 18 minutes. Using this filter, electrolytic reduction of carbon dioxide was performed in 0 C hot water with benzoin. This reaction produces aqueous oil from carbon dioxide and water. The products were compared with and without the filter and, although the yield did not differ between the two reaction systems, products without the filter contained highly polymerized oil compared to those with the filter. This suggests that the aqueous oil was produced at the cathode and polymerized at the anode.
Zhang, Shouwei; Demoustier-Champagne, Sophie; Jonas, Alain M
2015-08-10
We report on the fabrication of enzyme nanotubes in nanoporous polycarbonate membranes via the layer-by-layer (LbL) alternate assembly of polyethylenimine (PEI) and glucose oxidase (GOX), followed by dissolution of the sacrificial template in CH2Cl2, collection, and final dispersion in water. An adjuvant-assisted filtration methodology is exploited to extract quantitatively the nanotubes without loss of activity and morphology. Different water-soluble CH2Cl2-insoluble adjuvants are tested for maximal enzyme activity and nanotube stability; whereas NaCl disrupts the tubes by screening electrostatic interactions, the high osmotic pressure created by fructose also contributes to loosening the nanotubular structures. These issues are solved when using neutral, high molar mass dextran. The enzymatic activity of intact free nanotubes in water is then quantitatively compared to membrane-embedded nanotubes, showing that the liberated nanotubes have a higher catalytic activity in proportion to their larger exposed surface. Our study thus discloses a robust and general methodology for the fabrication and quantitative collection of enzymatic nanotubes and shows that LbL assembly provides access to efficient enzyme carriers for use as catalytic swarming agents.
Bid, Aveek; Bora, Achyut; Raychaudhuri, A K
2007-06-01
We have studied the resistance of metallic nanowires (silver and copper) as a function of the wire diameter in the temperature range 4.2 K-300 K. The nanowires with an average diameter of 15 nm-200 nm and length 6 microm were electrochemically deposited using polycarbonate membranes as template from AgNO3 and CuSO4, respectively. The wires after growth were removed from the membranes by dissolving the polymer in dichloromethane and their crystalline nature confirmed by XRD and TEM studies. The TEM study establishes that the nanowires are single crystalline and can have twin in them. The resistivity data was fitted to Bloch-Gruneisen theorem with the values of Debye temperature and the electron-acoustic phonon coupling constant as the two fit variables. The value of the Debye temperature obtained for the Ag wires was seen to match well with that of the bulk while for Cu wires a significant reduction was observed. The observed increase in resistivity with a decrease in the wire diameter could be explained as due to diffuse surface scattering of the conduction electrons.
NASA Technical Reports Server (NTRS)
Ponter, A. B.; Jones, W. R., Jr.; Jansen, R. H.
1994-01-01
Contact angles of water and methylene iodide were measured as a function of UV/O3 treatment time for three polymers: poly(methylmethacrylate) (PMMA), polycarbonate, and polytetrafluoroethylene (PTFE). Surface roughnesses were also measured. Surface free energies were then calculated using relationships developed by Kaelble and Neumann. The surface energy of polycarbonate was found to increase (60 percent) during UV/O3 treatment. However, calculations on PMMA were hampered by the formation of a water soluble surface product. On PTFE surfaces, the UV/O3 treatment etched the surface causing large increases in surface roughness, rendering contact angle measurements impossible. It is concluded that care must be taken in interpreting contact angle measurements and surface energy calculations on UV/O3 treated polymer surfaces.
The use of a behavioral response system in the USF/NASA toxicity screening test method
NASA Technical Reports Server (NTRS)
Hilado, C. J.; Cumming, H. J.; Packham, S. C.
1977-01-01
Relative toxicity data on the pyrolysis effluents from bisphenol A polycarbonate and wool fabric were obtained, based on visual observations of the behavior of free-moving mice and on an avoidance response behavioral paradigm of restrained rats monitored by an instrumented behavioral system. The initial experiments show an essentially 1:1 correlation between the two systems with regard to first signs of incapacitation, collapse, and death from pyrolysis effluents from polycarbonate. It is hypothesized that similarly good correlations between these two systems might exist for other materials exhibiting predominantly carbon monoxide mechanisms of intoxication. This hypothesis needs to be confirmed, however, by additional experiments. Data with wool fabric exhibited greater variability with both procedures, indicating possibly different mechanisms of intoxication for wool as compared with bisphenol A polycarbonate.
Mewes, D; Trapp, R P
2000-01-01
Guards on machine tools are meant to protect operators from injuries caused by tools, workpieces, and fragments hurled out of the machine's working zone. This article presents the impact resistance requirements, which guards according to European safety standards for machine tools must satisfy. Based upon these standards the impact resistance of different guard materials was determined using cylindrical steel projectiles. Polycarbonate proves to be a suitable material for vision panels because of its high energy absorption capacity. The impact resistance of 8-mm thick polycarbonate is roughly equal to that of a 3-mm thick steel sheet Fe P01. The limited ageing stability, however, makes it necessary to protect polycarbonate against cooling lubricants by means of additional panes on both sides.
Development of Polyvinylidene fluoride (PVDF)-ZIF-8 Membrane for Wastewater Treatment
NASA Astrophysics Data System (ADS)
Ibrahim, N. A.; Wirzal, M. D. H.; Nordin, N. A. H.; Halim, N. S. Abd
2018-04-01
Nowadays, the water shortage problem following the urbanization and increasing pollution of natural water source have increased the awareness to treat wastewater. Membrane filtration is often used in wastewater treatment plants to filter out more residual activated sludge from aeration process in the secondary stage. However, fouling is the main concern due to the fact it can happen to any membrane application. Antifouling properties in membrane can be improved by blending membranes with fillers or additives to make them more hydrophilic. This study aims to improve the antifouling properties in polyvinylidene fluoride (PVDF) membranes while optimizing the loading of Zeolitic imidazolate framework-8 (ZIF-8) fillers; at different loading (2.0 wt. %, 4.0 wt. %, 6.0 wt. %, 8.0 wt. % and 10.0 wt. %). Manual hand-casting of flat sheet membrane was done and the fabricated membranes were tested for their filterability against pure water and domestic wastewater. Both permeability tests showed that PVDF with 8% ZIF-8 membrane was the most permeable with a pure water and wastewater permeability of 150 L/m2.h.bar and 94 L/m2.h.bar, respectively. The pure water permeability of PVDF with 8% ZIF-8 membrane increases for about 130% compared to the pure PVDF membrane. The turbidity test of the initial feed and final permeate of wastewater, PVDF with 8% ZIF-8 membrane also gave out the highest reduction rate at 87%, which is 36% higher than that of pure PVDF membrane. It can be deduced that 8% of ZIF-8 is the ideal loading to PVDF in improving its antifouling properties to be used in domestic wastewater treatment.
Mizuguchi, Hitoshi; Matsuda, Yuki; Mori, Takehito; Uehara, Atsushi; Ishikawa, Yuta; Endo, Masatoshi; Shida, Junichi
2008-02-01
A new visual colorimetry for trace antimony(V) based on ion-pair solid-phase extraction to a PTFE-type membrane filter with bis[2-(5-chloro-2-pyridylazo)-5-diethylaminophenolato]cobalt(III) ion ([Co(5-Cl-PADAP)(2)](+)) has been developed. Experiments showed that hexachloroantimonate(V) ion (SbCl(6)(-)) was adsorbed with [Co(5-Cl-PADAP)(2)](+) to the front surface of the PTFE filter. The adsorption of antimony(V) ion was promoted by the addition of lithium chloride as a source of chloride ion. The excess reagent of [Co(5-Cl-PADAP)(2)](+) was eluted by rinsing with a 10 wt% methanol aqueous solution. In this case, the slow rate of the hydrolysis reaction of SbCl(6)(-) and the difference of the hydrophobicity of the ion pairs were important for adsorption and separation with a PTFE-type membrane filter. The antimony(V) concentration was determined through a visual comparison with a standard series. The visual detection limit was 0.10 microg. The calibration curve assessed with the reflection spectrometric responses at 580 nm was linear in the concentration range of 0.10 - 1.2 microg (r = 0.996). The proposed method has been applied to the determination of sub-microgram levels of antimony(V) ion in water samples.
NASA Astrophysics Data System (ADS)
Shiller, A. M.
2002-12-01
Methods for obtaining reliable dissolved trace element samples frequently utilize clean labs, portable laminar flow benches, or other equipment not readily transportable to remote locations. In some cases unfiltered samples can be obtained in a remote location and transported back to a lab for filtration. However, this may not always be possible or desirable. Additionally, methods for obtaining information on colloidal composition are likewise frequently too cumbersome for remote locations as well as being time-consuming. For that reason I have examined clean methods for collecting samples filtered through 0.45 and 0.02 micron syringe filters. With this methodology, only small samples are collected (typically 15 mL). However, with the introduction of the latest generation of ICP-MS's and microflow nebulizers, sample requirements for elemental analysis are much lower than just a few years ago. Thus, a determination of a suite of first row transition elements is frequently readily obtainable with samples of less than 1 mL. To examine the "traditional" (<0.45 micron) dissolved phase, 25 mm diameter polypropylene syringe filters and all polyethylene/polypropylene syringes are utilized. Filters are pre-cleaned in the lab using 40 mL of approx. 1 M HCl followed by a clean water rinse. Syringes are pre-cleaned by leaching with hot 1 M HCl followed by a clean water rinse. Sample kits are packed in polyethylene bags for transport to the field. Results are similar to results obtained using 0.4 micron polycarbonate screen filters, though concentrations may differ somewhat depending on the extent of sample pre-rinsing of the filter. Using this method, a multi-year time series of dissolved metals in a remote Rocky Mountain stream has been obtained. To examine the effect of colloidal material on dissolved metal concentrations, 0.02 micron alumina syringe filters have been utilized. Other workers have previously used these filters for examining colloidal Fe distributions in lake and sea water. Filters are pre-cleaned in the lab using clean pH 2 water followed by a clean water rinse and then dried with clean air. Because of the significant pressure that must be placed on the syringe for some minutes to effect a filtration, a simple plastic press and stand has been devised. Polarization artifacts, which can affect this type of ultra-filtration, do not appear to be significant. This may be due to the comparatively large pore size of these filters (equivalent to approx. 40 kDa). These filters, in combination with the 0.45 micron filters, are being used in a multi-year study of trace elements in the Yukon River system.
Effect of membrane filtration artifacts on dissolved trace element concentrations
Horowitz, Arthur J.; Elrick, Kent A.; Colberg, Mark R.
1992-01-01
Among environment scientists, the current and almost universally accepted definition of dissolved constituents is an operational one; only those materials which pass through a 0.45-??m membrane filter are considered to be dissolved. Detailed laboratory and field studies on Fe and Al indicate that a number of factors associated with filtration, other than just pore size, can substantially alter 'dissolved' trace element concentrations; these include: filter type, filter diameter, filtration method, volume of sample processed, suspended sediment concentration, suspended sediment grain-size distribution, concentration of colloids and colloidally associated trace elements and concentration of organic matter. As such, reported filtered-water concentrations employing the same pore size filter may not be equal. Filtration artifacts may lead to the production of chemical data that indicate seasonal or annual 'dissolved' chemical trends which do not reflect actual environmental conditions. Further, the development of worldwide averages for various dissolved chemical constituents, the quantification of geochemical cycles, and the determination of short- or long-term environmental chemical trends may be subject to substantial errors, due to filtration artifacts, when data from the same or multiple sources are combined. Finally, filtration effects could have a substantial impact on various regulatory requirements.
The effect of membrane filtration artifacts on dissolved trace element concentrations
Horowitz, A.J.; Elrick, K.A.; Colberg, M.R.
1992-01-01
Among environment scientists, the current and almost universally accepted definition of dissolved constituents is an operational one only those materials which pass through a 0.45-??m membrane filter are considered to be dissolved. Detailed laboratory and field studies on Fe and Al indicate that a number of factors associated with filtration, other than just pore size, can substantially alter 'dissolved' trace element concentrations; these include: filter type, filter diameter, filtration method, volume of sample processed, suspended sediment concentration, suspended sediment grain-size distribution, concentration of colloids and colloidally-associated trace elements and concentration of organic matter. As such, reported filtered-water concentrations employing the same pore size filter may not be equal. Filtration artifacts may lead to the production of chemical data that indicate seasonal or annual 'dissolved' chemical trends which do not reflect actual environmental conditions. Further, the development of worldwide averages for various dissolved chemical constituents, the quantification of geochemical cycles, and the determination of short- or long-term environmental chemical trends may be subject to substantial errors, due to filtration artifacts, when data from the same or multiple sources are combined. Finally, filtration effects could have a substantial impact on various regulatory requirements.
The DuPont/Oberlin microfiltration technology is a physical separation process that removes solid particles from liquid wastes. The process can filter particles that are submicron or larger in diameter. Pretreatment, such as chemical additions, will be required if dissolved con...
Henrich, Paul B; Valmaggia, Christophe; Lang, Corina; Cattin, Philippe C
2014-03-01
Vitreoretinal surgeons have been slow to adopt the use of spectral filters for endoillumination to reduce retinal light toxicity. This study shows that spectral filters can be used without a loss in color contrast during brilliant blue G chromovitrectomy. To evaluate the influence of intra operative spectral light filters on perceivable contrast during Brilliant Blue G chromovitrectomy, a prospective, observational clinical study was carried out on 59 consecutive Brilliant Blue G chromovitrectomy interventions in 59 patients admitted for macular holes, macular pucker or vitreomacular traction syndromes. Subsequent to peeling of the internal limiting membrane, six different illumination modes were enabled consecutively: mercury vapor, mercury vapor/xenon, and xenon followed by xenon combined with an amber, green or yellow spectral filter. Main outcome measure was the chromaticity spread between stained internal limiting membrane and unstained retina as a measure for the color contrast perceived by the human eye. Mean chromaticity scores were similar for all light sources: mercury vapor 7.97, mercury vapor/xenon 7.96 (p = 0.96), and xenon 7.41 (p = 0.55). Compared to xenon, the additional use of endoillumination spectral filters did not change contrast recognizability: Chromaticity scores were 9.38 for the amber filter (p = 0.13), 6.63 for the green and 7.02 for the yellow filter (p = 0.37 and 0.64, respectively). When comparing the different filters head-to-head, the amber filter was superior to the green filter (p = 0.03), while the yellow was intermediate and not significantly different from either the amber (p = 0.08) or the green filter (p = 0.51). Color contrast perceptibility during Brilliant Blue G assisted chromovitrectomy is similar with mercury vapor, mercury vapor/xenon or xenon light sources. Spectral filters do not decrease color contrast recognizability. Head-to-head comparison shows a significant advantage for the amber over the green filter with respect to contrast generation, the yellow filter is intermediate. As spectral filters are known to greatly reduce retinal light toxicity, we suggest donor eye studies to validate whether the amber filter should be generally recommended for Brilliant Blue G chromovitrectomy.
Apparatus and process for microbial detection and enumeration
NASA Technical Reports Server (NTRS)
Wilkins, J. R.; Grana, D. (Inventor)
1982-01-01
An apparatus and process for detecting and enumerating specific microorganisms from large volume samples containing small numbers of the microorganisms is presented. The large volume samples are filtered through a membrane filter to concentrate the microorganisms. The filter is positioned between two absorbent pads and previously moistened with a growth medium for the microorganisms. A pair of electrodes are disposed against the filter and the pad electrode filter assembly is retained within a petri dish by retainer ring. The cover is positioned on base of petri dish and sealed at the edges by a parafilm seal prior to being electrically connected via connectors to a strip chart recorder for detecting and enumerating the microorganisms collected on filter.
2012-01-01
We report on an exhaustive and systematic study about the photoluminescent properties of nanoporous anodic alumina membranes fabricated by the one-step anodization process under hard conditions in oxalic and malonic acids. This optical property is analysed as a function of several parameters (i.e. hard anodization voltage, pore diameter, membrane thickness, annealing temperature and acid electrolyte). This analysis makes it possible to tune the photoluminescent behaviour at will simply by modifying the structural characteristics of these membranes. This structural tuning ability is of special interest in such fields as optoelectronics, in which an accurate design of the basic nanostructures (e.g. microcavities, resonators, filters, supports, etc.) yields the control over their optical properties and, thus, upon the performance of the nanodevices derived from them (biosensors, interferometers, selective filters, etc.) PMID:22515214
Greene, C; Wu, J; Rickard, A H; Xi, C
2016-10-01
The human opportunistic pathogen, Acinetobacter baumannii, has the propensity to form biofilms and frequently cause medical device-related infections in hospitals. However, the physio-chemical properties of medical surfaces, in addition to bacterial surface properties, will affect colonization and biofilm development. The objective of this study was to compare the ability of A. baumannii to form biofilms on six different materials common to the hospital environment: glass, porcelain, stainless steel, rubber, polycarbonate plastic and polypropylene plastic. Biofilms were developed on material coupons in a CDC biofilm reactor. Biofilms were visualized and quantified using fluorescent staining and imaged using confocal laser scanning microscopy (CLSM) and by direct viable cell counts. Image analysis of CLSM stacks indicated that the mean biomass values for biofilms grown on glass, rubber, porcelain, polypropylene, stainless steel and polycarbonate were 0·04, 0·26, 0·62, 1·00, 2·08 and 2·70 μm(3) /μm(2) respectively. Polycarbonate developed statistically more biofilm mass than glass, rubber, porcelain and polypropylene. Viable cell counts data were in agreement with the CLSM-derived data. In conclusion, polycarbonate was the most accommodating surface for A. baumannii ATCC 17978 to form biofilms while glass was least favourable. Alternatives to polycarbonate for use in medical and dental devices may need to be considered. In the hospital environment, Acinetobacter baumannii is one of the most persistent and difficult to control opportunistic pathogens. The persistence of A. baumannii is due, in part, to its ability to colonize surfaces and form biofilms. This study demonstrates that A. baumannii can form biofilms on a variety of different surfaces and develops substantial biofilms on polycarbonate - a thermoplastic material that is often used in the construction of medical devices. The findings highlight the need to further study the in vitro compatibility of medical materials that could be colonized by A. baumannii and allow it to persist in hospital settings. © 2016 The Society for Applied Microbiology.
Favier, Valentin; Zemiti, Nabil; Caravaca Mora, Oscar; Subsol, Gérard; Captier, Guillaume; Lebrun, Renaud; Crampette, Louis; Mondain, Michel; Gilles, Benjamin
2017-01-01
Endoscopic skull base surgery allows minimal invasive therapy through the nostrils to treat infectious or tumorous diseases. Surgical and anatomical education in this field is limited by the lack of validated training models in terms of geometric and mechanical accuracy. We choose to evaluate several consumer-grade materials to create a patient-specific 3D-printed skull base model for anatomical learning and surgical training. Four 3D-printed consumer-grade materials were compared to human cadaver bone: calcium sulfate hemihydrate (named Multicolor), polyamide, resin and polycarbonate. We compared the geometric accuracy, forces required to break thin walls of materials and forces required during drilling. All materials had an acceptable global geometric accuracy (from 0.083mm to 0.203mm of global error). Local accuracy was better in polycarbonate (0.09mm) and polyamide (0.15mm) than in Multicolor (0.90mm) and resin (0.86mm). Resin and polyamide thin walls were not broken at 200N. Forces needed to break Multicolor thin walls were 1.6-3.5 times higher than in bone. For polycarbonate, forces applied were 1.6-2.5 times higher. Polycarbonate had a mode of fracture similar to the cadaver bone. Forces applied on materials during drilling followed a normal distribution except for the polyamide which was melted. Energy spent during drilling was respectively 1.6 and 2.6 times higher on bone than on PC and Multicolor. Polycarbonate is a good substitute of human cadaver bone for skull base surgery simulation. Thanks to short lead times and reasonable production costs, patient-specific 3D printed models can be used in clinical practice for pre-operative training, improving patient safety.
Meyer, Brian K; Vargas, Diego
2006-01-01
The following study was conducted to determine the effect of different preservatives commonly used in the biopharmaceutical industry on the product-specific bubble point of sterilizing-grade filters when used to filter product processed with different types of tubing. The preservatives tested were 0.25% phenol, m-cresol, and benzyl alcohol. The tubing tested was Sani-Pure (platinum-cured silicone tubing), Versilic (peroxide-cured silicone tubing), C-Flex, Pharmed, and Cole-Parmer (BioPharm silicone tubing). The product-specific bubble point values of sterilizing grade filters were measured after the recirculation of product through the filter and tubing of different types of materials for a total contact time of 15 h. When silicone tubing was used, the post-recirculation product-specific bubble point was suppressed on average 13 psig when compared to the pre- recirculation product-specific bubble point. Suppression was also observed with C-Flex, but to a much lesser extent than with silicone tubing. Suppression was not observed with Pharmed or BioPharm tubing. Alcohol extractions performed on the filters that experienced suppressed bubble points followed by Fourier transform infrared spectroscopy analysis indicated the filters contained poly(dimethylsiloxane). Direct addition of poly(dimethlysiloxane) to solutions filtered through sterilizing-grade filters suppressed the filter bubble points when tested for integrity. Silicone oils most likely reduced the surface tension of the pores in the membrane, resulting in the ability of air (or nitrogen) to pass more freely through the membrane, causing suppressed bubble point test values. The results of these studies indicate that product-specific bubble point of a filter determined with only product may not reflect the true bubble point for preservative-containing products that are recirculated or contacted with certain tubing for 15 h or greater. In addition, tubing material placed in contact with products containing preservatives should be evaluated for impact to the product-specific bubble point when being utilized with sterilizing-grade filters.
Surface and interfacial properties of carbon fibers
NASA Technical Reports Server (NTRS)
Bascom, Willard D.
1991-01-01
The adhesion strength of AS4 fibers to thermoplastic polymers was determined. The specific polymers were polycarbonate, polyphenylene oxide, polyetherimide, polyphenylene oxide blends with polystyrene, and polycarbonate blends with a polycarbonate-polysiloxan copolymer. Data are also included for polysulfone. It was recognized at the outset that an absolute measure of the fiber matrix adhesion would be difficult. However, it is feasible to determine the fiber bond strengths to the thermoplastics relative to the bond strengths of the same fibers to epoxy polymers. It was anticipated, and in fact realized, that the adhesion of AS4 to the thermoplastic polymers was relatively low. Therefore, further objectives of the study were to identify means of increasing fiber/matrix adhesion and to try to determine why the adhesion of AS4 to thermoplastics is significantly less than to epoxy polymers.
Bio-based polycarbonate as synthetic toolbox
NASA Astrophysics Data System (ADS)
Hauenstein, O.; Agarwal, S.; Greiner, A.
2016-06-01
Completely bio-based poly(limonene carbonate) is a thermoplastic polymer, which can be synthesized by copolymerization of limonene oxide (derived from limonene, which is found in orange peel) and CO2. Poly(limonene carbonate) has one double bond per repeating unit that can be exploited for further chemical modifications. These chemical modifications allow the tuning of the properties of the aliphatic polycarbonate in nearly any direction. Here we show synthetic routes to demonstrate that poly(limonene carbonate) is the perfect green platform polymer, from which many functional materials can be derived. The relevant examples presented in this study are the transformation from an engineering thermoplastic into a rubber, addition of permanent antibacterial activity, hydrophilization and even pH-dependent water solubility of the polycarbonate. Finally, we show a synthetic route to yield the completely saturated counterpart that exhibits improved heat processability due to lower reactivity.
Protein patterning in polycarbonate microfluidic channels
NASA Astrophysics Data System (ADS)
Thomson, David A.; Hayes, Jason P.; Thissen, Helmut
2004-03-01
In this work protein patterning has been achieved within a polycarbonate microfluidic device. Channel structures were first coated with plasma polymerized allylamine (ALAPP) followed by the "cloud point" deposition of polyethylene oxide (PEO), a protein repellent molecule. Excimer laser micromachining was used to pattern the PEO to control protein localization. Subsequent removal of a sacrificial layer of polycarbonate resulted in the patterned polymer coating only in the channels of a simple fluidic device. Following a final diffusion bonding fabrication step the devices were filled with a buffer containing Streptavidin conjugated with fluorescein, and visualized under a confocal fluorescent microscope. This confirmed that protein adhesion occurred only in laser patterned areas. The ability to control protein adhesion in microfludic channels leads to the possibility of generating arrays of proteins or cells within polymer microfludics for cheap automated biosensors and synthesis systems.
High-throughput single-molecule force spectroscopy for membrane proteins
NASA Astrophysics Data System (ADS)
Bosshart, Patrick D.; Casagrande, Fabio; Frederix, Patrick L. T. M.; Ratera, Merce; Bippes, Christian A.; Müller, Daniel J.; Palacin, Manuel; Engel, Andreas; Fotiadis, Dimitrios
2008-09-01
Atomic force microscopy-based single-molecule force spectroscopy (SMFS) is a powerful tool for studying the mechanical properties, intermolecular and intramolecular interactions, unfolding pathways, and energy landscapes of membrane proteins. One limiting factor for the large-scale applicability of SMFS on membrane proteins is its low efficiency in data acquisition. We have developed a semi-automated high-throughput SMFS (HT-SMFS) procedure for efficient data acquisition. In addition, we present a coarse filter to efficiently extract protein unfolding events from large data sets. The HT-SMFS procedure and the coarse filter were validated using the proton pump bacteriorhodopsin (BR) from Halobacterium salinarum and the L-arginine/agmatine antiporter AdiC from the bacterium Escherichia coli. To screen for molecular interactions between AdiC and its substrates, we recorded data sets in the absence and in the presence of L-arginine, D-arginine, and agmatine. Altogether ~400 000 force-distance curves were recorded. Application of coarse filtering to this wealth of data yielded six data sets with ~200 (AdiC) and ~400 (BR) force-distance spectra in each. Importantly, the raw data for most of these data sets were acquired in one to two days, opening new perspectives for HT-SMFS applications.
Koo, Won-Tae; Jang, Ji-Soo; Qiao, Shaopeng; Hwang, Wontae; Jha, Gaurav; Penner, Reginald M; Kim, Il-Doo
2018-06-13
Here, we propose heterogeneous nucleation-assisted hierarchical growth of metal-organic frameworks (MOFs) for efficient particulate matter (PM) removal. The assembly of two-dimensional (2D) Zn-based zeolite imidazole frameworks (2D-ZIF-L) in deionized water over a period of time produced hierarchical ZIF-L (H-ZIF-L) on hydrophilic substrates. During the assembly, the second nucleation and growth of ZIF-L occurred on the surface of the first ZIF-L, leading to the formation of flowerlike H-ZIF-L on the substrate. The flowerlike H-ZIF-L was easily synthesized on various substrates, namely, glass, polyurethane three-dimensional foam, nylon microfibers, and nonwoven fabrics. We demonstrated H-ZIF-L-assembled polypropylene microfibers as a washable membrane filter with highly efficient PM removal property (92.5 ± 0.8% for PM 2.5 and 99.5 ± 0.2% for PM 10 ), low pressure drop (10.5 Pa at 25 L min -1 ), long-term stability, and superior recyclability. These outstanding particle filtering properties are mainly attributed to the unique structure of the 2D-shaped H-ZIF-L, which is tightly anchored on individual fibers comprising the membrane.
Ion-binding properties of a K+ channel selectivity filter in different conformations.
Liu, Shian; Focke, Paul J; Matulef, Kimberly; Bian, Xuelin; Moënne-Loccoz, Pierre; Valiyaveetil, Francis I; Lockless, Steve W
2015-12-08
K(+) channels are membrane proteins that selectively conduct K(+) ions across lipid bilayers. Many voltage-gated K(+) (KV) channels contain two gates, one at the bundle crossing on the intracellular side of the membrane and another in the selectivity filter. The gate at the bundle crossing is responsible for channel opening in response to a voltage stimulus, whereas the gate at the selectivity filter is responsible for C-type inactivation. Together, these regions determine when the channel conducts ions. The K(+) channel from Streptomyces lividians (KcsA) undergoes an inactivation process that is functionally similar to KV channels, which has led to its use as a practical system to study inactivation. Crystal structures of KcsA channels with an open intracellular gate revealed a selectivity filter in a constricted conformation similar to the structure observed in closed KcsA containing only Na(+) or low [K(+)]. However, recent work using a semisynthetic channel that is unable to adopt a constricted filter but inactivates like WT channels challenges this idea. In this study, we measured the equilibrium ion-binding properties of channels with conductive, inactivated, and constricted filters using isothermal titration calorimetry (ITC). EPR spectroscopy was used to determine the state of the intracellular gate of the channel, which we found can depend on the presence or absence of a lipid bilayer. Overall, we discovered that K(+) ion binding to channels with an inactivated or conductive selectivity filter is different from K(+) ion binding to channels with a constricted filter, suggesting that the structures of these channels are different.
Imoto, Yukari; Yasutaka, Tetsuo; Someya, Masayuki; Higashino, Kazuo
2018-05-15
Soil leaching tests are commonly used to evaluate the leachability of hazardous materials, such as heavy metals, from the soil. Batch leaching tests often enhance soil colloidal mobility and may require solid-liquid separation procedures to remove excess soil particles. However, batch leaching test results depend on particles that can pass through a 0.45μm membrane filter and are influenced by test parameters such as centrifugal intensity and filtration volume per filter. To evaluate these parameters, we conducted batch leaching experiments using metal-contaminated soils and focused on the centrifugal intensity and filtration volume per filter used in solid-liquid separation methods currently employed in standard leaching tests. Our experiments showed that both centrifugal intensity and filtration volume per filter affected the reproducibility of batch leaching tests for some soil types. The results demonstrated that metal concentrations in the filtrates significantly differed according to the centrifugal intensity when it was 3000 g for 2h or less. Increased filtration volume per filter led to significant decreases in filtrate metal concentrations when filter cakes formed during filtration. Comparison of the filtration tests using 0.10 and 0.45μm membrane filters showed statistically significant differences in turbidity and metal concentration. These findings suggest that colloidal particles were not adequately removed from the extract and contributed substantially to the apparent metal concentrations in the leaching test of soil containing colloidal metals. Copyright © 2017 The Authors. Published by Elsevier B.V. All rights reserved.
Yao, Yuan; Li, Gonghu; Gray, Kimberly A; Lueptow, Richard M
2008-07-15
We report that SWCNTs substantially improve the uniformity and coverage of TiO2 coatings on porous ZrO2 ceramic membrane filters. The ZrO2 filters were dip coated with 100 nm anatase TiO2, TiO2/SWCNT composites, a TiO2+SWCNT mixture, and a TiO2/MWCNT composite at pH 3, 5, and 8. Whereas the TiO2+SWCNT mixture and the TiO2/MWCNT composite promote better coverage and less clumping than TiO2 alone, the TiO2/SWCNT composite forms a complete uniform coating without cracking at pH 5 ( approximately 100% coverage). A combination of chemical and electrostatic effects between TiO2 and SWCNTs forming the composite as well as between the composite and the ZrO2 surface explains these observations.
FILTRATION ARTIFACTS CAUSED BY OVERLOADING MEMBRANE FILTERS. (R825395)
The conventional practice of using 0.45 or 0.40 src="/ncer/pubs/images/mgr.gif">m membranes to distinguish between the
particulate and dissolved phases in natural waters neglects the importance of
colloids. Many of the colloids in natural waters pass through 0...
Membrane-filtered olive mill wastewater: Quality assessment of the dried phenolic-rich fraction
USDA-ARS?s Scientific Manuscript database
A current trend in olive mill wastewater (OMWW) management is to not only decrease environmental pollution but also extract and utilize valuable by-products. Therefore, the objectives of this study were to explore different techniques for drying a phenolic-rich membrane filtration fraction of OMWW a...
NASA Astrophysics Data System (ADS)
Gao, Changfei; Liu, Lifen; Yang, Fenglin
2018-03-01
A novel conductive membrane with Fe/Mn/C/F/O elements is developed, it functions as the catalytic cathode of MFC and the antifouling filter of MBR simultaneously, in a newly designed integrated wastewater treatment system, without proton exchange membrane (PEM). The optimal conductive membrane is characterized using SEM-EDX, XRD and XPS. BET and porous structure analysis of the grounded membrane material indicate a narrow and small pore size (2-7 nm). The membrane surface is rich in Fe species (Fe - Fe2O3- Fe3O4) and manganese oxide (MnO2). Its characteristics such as excellent electro-chemical oxygen reduction reaction (ORR) activity, high clear water flux (>240 L/(m2·h)) and better antifouling filtration performance are further confirmed. The new system features bio-electrochemical system (BES) and integrates bio-filtration (trickling filter and air contact oxidation bed) and proton transfer through quartz sand chamber (QSC) which eliminates the use of expensive proton exchange membrane. The system removes chemical oxygen demand (>97.4%), ammonia nitrogen (>96.7%), total phosphorus (>98.0%) effectively, and it simultaneously generates electricity (446 mW/m3). The low cost and high performances, economic and advantageous system has good compatibility with existing wastewater treatment facilities and a wide application prospect.
Multi-wavelength Characterization of Brown and Black Carbon from Filter Samples
NASA Astrophysics Data System (ADS)
Johnson, M. M.; Yatavelli, R. L. N.; Chen, L. W. A. A.; Gyawali, M. S.; Arnott, W. P.; Wang, X.; Chakrabarty, R. K.; Moosmüller, H.; Watson, J. G.; Chow, J. C.
2014-12-01
Particulate matter (PM) scatters and absorbs solar radiation and thereby affects visibility, the Earth's radiation balance, and properties and lifetimes of clouds. Understanding the radiative forcing (RF) of PM is essential to reducing the uncertainty in total anthropogenic and natural RF. Many instruments that measure light absorption coefficients (βabs [λ], Mm-1) of PM have used light at near-infrared (NIR; e.g., 880 nm) or red (e.g., 633 nm) wavelengths. Measuring βabs over a wider wavelength range, especially including the ultraviolet (UV) and visible, allows for contributions from black carbon (BC), brown carbon (BrC), and mineral dust (MD) to be differentiated. This will help to determine PM RF and its emission sources. In this study, source and ambient samples collected on Teflon-membrane and quartz-fiber filters are used to characterize and develop a multi-wavelength (250 - 1000 nm) filter-based measurement method of PM light absorption. A commercially available UV-visible spectrometer coupled with an integrating sphere is used for quantifying diffuse reflectance and transmittance of filter samples, from which βabs and absorption Ǻngström exponents (AAE) of the PM deposits are determined. The filter-based light absorption measurements of laboratory generated soot and biomass burning aerosol are compared to 3-wavelength photoacoustic absorption measurements to evaluate filter media and loading effects. Calibration factors are developed to account for differences between filter types (Teflon-membrane vs. quartz-fiber), and between filters and in situ photoacoustic absorption values. Application of multi-spectral absorption measurements to existing archived filters, including specific source samples (e.g. diesel and gasoline engines, biomass burning, dust), will also be discussed.
An emerging technology called radial flow fluidized filter (R3f) has been developed as a low cost simplistic filtration technology for small communities of less than 10,000 people. Fouling is a major impediment to the sustainability of membrane technology particularly for small ...
Pan, Z.; Chou, I-Ming; Burruss, R.C.
2009-01-01
The advantages of using fused silica capillary reactor (FSCR) instead of conventional autoclave for studying chemical reactions at elevated pressure and temperature conditions were demonstrated in this study, including the allowance for visual observation under a microscope and in situ Raman spectroscopic characterization of polycarbonate and coexisting phases during hydrolysis in subcritical water.
Internal stabilization of polycarbonate resins by two stage radiation process
NASA Technical Reports Server (NTRS)
Gupta, Amitava (Inventor); Liang, Ranty H. (Inventor); Yavrouian, Andre H. (Inventor)
1988-01-01
A new polycarbonate copolymer resin is formed by internal generation of stabilizers bound to the polymer chain. Irradiation of a solid piece or a deoxygenated solution of the resin at a first frequency below 300 nm generates 2 to 8 mol percent of phenyl salicylate groups which are rearranged to dihydroxybenzophenone groups by irradiating the resin under oxygen excluding conditions at a second frequency from 300 to 320 nm.
Effects of Solvents on Craze Initiation and Crack Propagation in Transparent Polymers
1989-04-01
methyl methacrylate) ( PMMA ) materials, as well as several formulations of polycarbon- ate, show a range of critical strain measurements in crazing...propagation in transparent polymers is demonstrated by a dead weight loading apparatus and compact tension specimens based on ASTM E 399. Samples of PMMA ...environment. This includes the ability to be decontaminated. Polycarbonate (PC) and poly(methyl methacrylate) ( PMMA ) are known to craze while undfer
DARPA Perspectives on Multifunctional Materials/Power and Energy
2012-08-09
In-situ growth of aligned CNTs Electronics Graphene /Metal oxide CMOS interconnects Erosion Diamond/ZnS LWIR missile domes Tribology TiN/Carbon...application Optoelectronics InGaN LEDs Energy ZnSnN2 Photovoltaics Optoelectronics Indium Tin Oxide/ Polycarbonate Anti-corrosion Paint /Steel...InGaN LEDs Energy ZnSnN2 Photovoltaics Optoelectronics Indium Tin Oxide/ Polycarbonate Anti-corrosion Paint /Steel Tribology TiN/High speed
Experimental set up for the irradiation of biological samples and nuclear track detectors with UV C
Portu, Agustina Mariana; Rossini, Andrés Eugenio; Gadan, Mario Alberto; Bernaola, Omar Alberto; Thorp, Silvia Inés; Curotto, Paula; Pozzi, Emiliano César Cayetano; Cabrini, Rómulo Luis; Martin, Gisela Saint
2016-01-01
Aim In this work we present a methodology to produce an “imprint” of cells cultivated on a polycarbonate detector by exposure of the detector to UV C radiation. Background The distribution and concentration of 10B atoms in tissue samples coming from BNCT (Boron Neutron Capture Therapy) protocols can be determined through the quantification and analysis of the tracks forming its autoradiography image on a nuclear track detector. The location of boron atoms in the cell structure could be known more accurately by the simultaneous observation of the nuclear tracks and the sample image on the detector. Materials and Methods A UV C irradiator was constructed. The irradiance was measured along the lamp direction and at different distances. Melanoma cells were cultured on polycarbonate foils, incubated with borophenylalanine, irradiated with thermal neutrons and exposed to UV C radiation. The samples were chemically attacked with a KOH solution. Results A uniform irradiation field was established to expose the detector foils to UV C light. Cells could be seeded on the polycarbonate surface. Both imprints from cells and nuclear tracks were obtained after chemical etching. Conclusions It is possible to yield cellular imprints in polycarbonate. The nuclear tracks were mostly present inside the cells, indicating a preferential boron uptake. PMID:26933396
Wu, Ruizhi; Al-Azemi, Talal F; Bisht, Kirpal S
2008-10-01
Enantiomerically pure functional polycarbonate was synthesized from a novel seven-membered cyclic carbonate monomer derived from naturally occurring L-tartaric acid. The monomer was synthesized in three steps and screened for polymerization with four commercially available lipases from different sources at 80 degrees C, in bulk. The ring-opening polymerization (ROP) was affected by the source of the enzyme; the highest number-average molecular weight, M(n) = 15500 g/mol (PDI = 1.7; [alpha]D(20) = +77.8, T(m) = 58.8 degrees C) optically active polycarbonate was obtained with lipase Novozyme-435. The relationship between monomer conversion, reaction time, molecular weight, and molecular weight distribution were investigated for Novozyme-435 catalyzed ROP. Deprotection of the ketal groups was achieved with minimal polymer chain cleavage (M(n) = 10000 g/mol, PDI = 2.0) and resulted in optically pure polycarbonate ([alpha]D(20) = +56) bearing hydroxy functional groups. Deprotected poly(ITC) shows T(m) of 60.2 degrees C and DeltaH(f) = 69.56 J/g and similar to that of the poly(ITC), a glass transition temperature was not found. The availability of the pendant hydroxyl group is expected to enhance the biodegradability of the polymer and serves in a variety of potential biomedical applications such as polymeric drug delivery systems.
Shatter resistance of spectacle lenses.
Vinger, P F; Parver, L; Alfaro, D V; Woods, T; Abrams, B S
1997-01-08
To evaluate the relative strength and shatter resistance of spectacle lenses currently used in sunglasses and dress, sports, and industrial eyewear. Seven lenses that met the US American National Standards Institute (ANSI) Z80 standards for dress glasses (made of high-index plastic, allyl resin plastic, heat tempered glass, chemically tempered glass, and polycarbonate, and with center thickness ranging from 1 mm to 2.2 mm) and 4 lenses that met ANSI Z87 standards for industrial safety eyewear (allyl resin plastic, heat-tempered glass, chemically tempered glass, and polycarbonate, all with 3.0-mm center thickness) were tested for impact resistance to 5 projectiles (air gun pellets, golf balls, tennis balls, lacrosse balls, and baseballs). Impact energy required to shatter spectacle lenses. Based on 348 lens impacts, dress and industrial lenses made from glass, allyl resin plastic, and high-index plastic shattered at impact energies less than those expected to be encountered from the test projectiles during their routine use. Polycarbonate lenses demonstrated resistance to impact for all tested projectiles exceeding the impact potential expected during routine use. Under the test conditions of this study, polycarbonate lenses demonstrated greater impact resistance than other commonly used spectacle lenses that conform to prevailing eyewear standards. These findings suggest that current ANSI Z80 and ANSI Z87 standards should be reevaluated.
Evans, R.J.; Chum, H.L.
1994-06-14
A process is described using fast pyrolysis to convert a plastic waste feed stream containing polycarbonate and ABS to high value monomeric constituents prior to pyrolysis of other plastic components therein comprising: selecting a first temperature program range to cause pyrolysis of a given polymer to its high value monomeric constituents prior to a temperature range that causes pyrolysis of other plastic components; selecting an acid or base catalysts and an oxide or carbonate support for treating the feed stream to affect acid or base catalyzed reaction pathways to maximize yield or enhance separation of the high value monomeric constituents of polycarbonate and ABS in the first temperature program range; differentially heating the feed stream at a heat rate within the first temperature program range to provide differential pyrolysis for selective recovery of optimum quantities of the high value monomeric constituents prior to pyrolysis or other plastic components; separating the high value monomeric constituents from the polycarbonate to cause pyrolysis to a different high value monomeric constituent of the plastic waste and differentially heating the feed stream at the second higher temperature program range to cause pyrolysis of different high value monomeric constituents; and separating the different high value monomeric constituents. 68 figs.
NASA Technical Reports Server (NTRS)
Caneba, Gerard T.
2005-01-01
The fellowship experience for this summer for 2004 pertains to carbon nanotube coatings for various space-related applications. They involve the following projects: (a) EMI protection films from HiPco-polymers, and (b) Thermal protection nanosilica materials. EMI protection films are targeted to be eventually applied onto casings of laptop computers. These coatings are composites of electrically-conductive SWNTs and compatible polymers. The substrate polymer will be polycarbonate, since computer housings are typically made of carbon composites of this type of polymer. A new experimental copolymer was used last year to generate electrically-conductive and thermal films with HiPco at 50/50 wt/wt composition. This will be one of the possible formulations. Reference films will be base polycarbonate and neat HiPco onto polycarbonate films. Other coating materials that will be tried will be based on HiPco composites with commercial enamels (polyurethane, acrylic, polyester), which could be compatible with the polycarbonate substrate. Nanosilica fibers are planned for possible use as thermal protection tiles on the shuttle orbiter. Right now, microscale silica is used. Going to the nanoscale will increase the surface-volume-per-unit-area of radiative heat dissipation. Nanoscale carbon fibers/nanotubes can be used as templates for the generation of nanosilica. A sol-gel operation is employed for this purpose.
Evans, Robert J.; Chum, Helena L.
1994-01-01
A process of using fast pyrolysis to convert a plastic waste feed stream containing polycarbonate and ABS to high value monomeric constituents prior to pyrolysis of other plastic components therein comprising: selecting a first temperature program range to cause pyrolysis of a given polymer to its high value monomeric constituents prior to a temperature range that causes pyrolysis of other plastic components; selecting an acid or base catalysts and an oxide or carbonate support for treating the feed stream to affect acid or base catalyzed reaction pathways to maximize yield or enhance separation of the high value monomeric constituents of polycarbonate and ABS in the first temperature program range; differentially heating the feed stream at a heat rate within the first temperature program range to provide differential pyrolysis for selective recovery of optimum quantities of the high value monomeric constituents prior to pyrolysis or other plastic components; separating the high value monomeric constituents from the polycarbonate to cause pyrolysis to a different high value monomeric constituent of the plastic waste and differentially heating the feed stream at the second higher temperature program range to cause pyrolysis of different high value monomeric constituents; and separating the different high value monomeric constituents.
Kim, Yong Tae; Park, Kyun Joo; Kim, Seyl; Kim, Soon Ae; Lee, Seok Jae; Kim, Do Hyun; Lee, Tae Jae; Lee, Kyoung G
2018-03-01
Isolation of specific cells from whole blood is important to monitor disease prognosis and diagnosis. In this study, a vibration-assisted filtration (VF) device has been developed for isolation and recovery of specific cells such as leukocytes and pathogenic bacteria from human whole blood. The VF device is composed of three layers which was fabricated using injection molding with cyclic olefin copolymer (COC) pellets consisting of: a top layer with coin-type vibration motor (Ф = 10mm), a middle plate with a 1μm or 3μm-pore filter membrane to separate of Staphylococcus aureus (S. aureus) cells or leukocytes (i.e. white blood cells) respectively, and a bottom chamber with conical-shaped microstructure. One milliliter of human whole blood was injected into a sample loading chamber using a 3μm-pore filter equipped in the VF device and the coin-type vibration motor applied external vibration force by generating a rotational fluid which enhances the filtration velocity due to the prevention of the cell clogging on the filter membrane. The effluent blood such as erythrocytes, platelet, and plasma was collected at the bottom chamber while the leukocytes were sieved by the filter membrane. The vibration-assisted leukocyte separation was able to finish within 200s while leukocyte separation took 1200s without vibration. Moreover, we successfully separated S. aureus from human whole blood using a 1μm-pore filter equipped VF device and it was further confirmed by genetic analysis. The proposed VF device provides an advanced cell separation platform in terms of simplicity, fast separation, and portability in the fields of point-of-care diagnostics. Copyright © 2017 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Fahrul Hassan, Mohd; Jusoh, Suhada; Zaini Yunos, Muhamad; Arifin, A. M. T.; Ismail, A. E.; Rasidi Ibrahim, M.; Zulafif Rahim, M.
2017-09-01
Portable water filter has grown significantly in recent years. The use of water bottles as a water drink stuff using hand pump water filtration unit has been suggested to replace water bottled during outdoor recreational activities and for emergency supplies. However, quality of water still the issue related to contaminated water due to the residual waste plants, bacteria, and so on. Based on these issues, the study was carried out to design a portable water filter that uses membrane filtration system by applying Design for Six Sigma. Design for Six Sigma methodology consists of five stages which is Define, Measure, Analyze, Design and Verify. There were several tools have been used in each stage in order to come out with a specific objective. In the Define stage, questionnaire approach was used to identify the needs of portable water filter in the future from potential users. Next, Quality Function Deployment (QFD) tool was used in the Measure stage to measure the users’ needs into engineering characteristics. Based on the information in the Measure stage, morphological chart and weighted decision matrix tools were used in the Analyze stage. This stage performed several activities including concept generation and selection. Once the selection of the final concept completed, detail drawing was made in the Design stage. Then, prototype was developed in the Verify stage to conduct proof-of-concept testing. The results that obtained from each stage have been reported in this paper. From this study, it can be concluded that the application of Design for Six Sigma in designing a future portable water filter that uses membrane filtration system is a good start in looking for a new alternative concept with a completed supporting document.
Frequency-Dependent Capacitance of Hydrophobic Membranes Containing Fixed Negative Charges
Ilani, Asher
1968-01-01
Filters containing fixed negative charges were saturated with hydrophobic solvent and interposed between aqueous solutions. The capacitance of such membranes was measured in the frequency range of 0.05-30 kc. The capacitance increased with decrease in frequency. The frequency dependence of the capacitance was sensitive to nature of the cation present and to salt concentration in the aqueous solution. It is suggested that variation of membrane resistivity in the space charge region of the membrane is responsible for this phenomenon. Possible effects of the potential and counterion concentration profiles at the membrane-water interface are discussed. PMID:5699796
The pressure-dependence of the size of extruded vesicles.
Patty, Philipus J; Frisken, Barbara J
2003-08-01
Variations in the size of vesicles formed by extrusion through small pores are discussed in terms of a simple model. Our model predicts that the radius should decrease as the square root of the applied pressure, consistent with data for vesicles extruded under various conditions. The model also predicts dependencies on the pore size used and on the lysis tension of the vesicles being extruded that are consistent with our data. The pore size was varied by using track-etched polycarbonate membranes with average pore diameters ranging from 50 to 200 nm. To vary the lysis tension, vesicles made from POPC (1-palmitoyl-2-oleoyl-sn-glycero-3-phosphatidylcholine), mixtures of POPC and cholesterol, and mixtures of POPC and C(16)-ceramide were studied. The lysis tension, as measured by an extrusion-based technique, of POPC:cholesterol vesicles is higher than that of pure POPC vesicles whereas POPC:ceramide vesicles have lower lysis tensions than POPC vesicles.
A Novel Counter Sheet-flow Sandwich Cell Culture Device for Mammalian Cell Growth in Space
NASA Astrophysics Data System (ADS)
Sun, Shujin; Gao, Yuxin; Shu, Nanjiang; Tang, Zemei; Tao, Zulai; Long, Mian
2008-08-01
Cell culture and growth in space is crucial to understand the cellular responses under microgravity. The effects of microgravity were coupled with such environment restrictions as medium perfusion, in which the underlying mechanism has been poorly understood. In the present work, a customer-made counter sheet-flow sandwich cell culture device was developed upon a biomechanical concept from fish gill breathing. The sandwich culture unit consists of two side chambers where the medium flow is counter-directional, a central chamber where the cells are cultured, and two porous polycarbonate membranes between side and central chambers. Flow dynamics analysis revealed the symmetrical velocity profile and uniform low shear rate distribution of flowing medium inside the central culture chamber, which promotes sufficient mass transport and nutrient supply for mammalian cell growth. An on-orbit experiment performed on a recovery satellite was used to validate the availability of the device.
[Acute toxicity analysis performance of CellSense biosensor with E. coli].
Wang, Xue-Jiang; Wang, Hong; Zhao, Jian-Fu; Xia, Si-Qing; Zhao, Hong-Ning
2009-04-15
E. coli microbial electrodes for CellSense biosensor were prepared by polycarbonate membrane immobilization process, and their performance for heavy metals and toxic organic compounds acute toxicity determination were studied. The results showed that when E. coli was in logarithmic and stationary phase, the CellSense biosensor with E. coli showed good performance in heavy metal ions and organic pollutants acute toxicity analysis, when E. coli was in its decline phase, the stability and sensitivity of the CellSense biosensor was poor. The EC50 values of Hg2+, Cu2+, Zn2+, o-chlorophenol (2-CP) and p-nitrophenol (4-NP) detected by CellSense biosensor with E. coli were 0.6, 3.1, 5.8, 180 and 94 microg/mL, respectively. The immobilized E. coli electrodes could still suit for acute toxicity assessment after 2 months storage at 4 degrees C.
[Decontamination of dental unit waterlines using disinfectants and filters].
Monarca, S; Garusi, G; Gigola, P; Spampinato, L; Zani, C; Sapelli, P L
2002-10-01
Bacterial contamination of the dental unit water system can become a health problem for patients, particularly if they are immunodepressed. The present study has had the purpose of evaluating the effectiveness of methods of chemical decontamination using different disinfectants (peracetic acid, hydrogen peroxide, silver salts, chloramine T, glutaraldehyde T4) and methods of physical decontamination using synthetic membranes for the filtration of water. A preliminary removal procedure of the biofilm present in the waterline has been followed in a dental unit prepared on purpose for the research; subsequently different 2-week long maintenance procedures were applied using disinfectants injected by a pump and finally the bacterial contamination of the water flowing from the waterline was evaluated. The physical decontamination was performed using 0.22 mm membrane filters, which have been installed also in another dental unit, and the filtered water was analyzed to detect bacterial contamination. The preliminary procedure of biofilm removal succeeded obtaining germ-free water. Among the disinfectants used for the maintenance of the water quality only glutaraldehyde T4 was able to reduce the bacterial contamination under the limit suggested by the ADA. The membrane filter system was not able to purify the water, but when a disinfectant (peracetic acid) was used in the last part of the waterline good results were obtained. At present no decontamination system of dental waterline is available, and glutaraldehyde T4 seems to be the best disinfectant only if integrated with periodic biofilm removal for the maintenance of the water quality.
Saleem, Mahmood; Khan, Rafi Ullah; Tahir, M. Suleman; Krammer, Gernot
2011-01-01
Pulse-jet bag filters are frequently employed for particle removal from off gases. Separated solids form a layer on the permeable filter media called filter cake. The cake is responsible for increasing pressure drop. Therefore, the cake has to be detached at a predefined upper pressure drop limit or at predefined time intervals. Thus the process is intrinsically semi-continuous. The cake formation and cake detachment are interdependent and may influence the performance of the filter. Therefore, understanding formation and detachment of filter cake is important. In this regard, the filter media is the key component in the system. Needle felts are the most commonly used media in bag filters. Cake formation studies with heat treated and membrane coated needle felts in pilot scale pulse jet bag filter were carried out. The data is processed according to the procedures that were published already [Powder Technology, Volume 173, Issue 2, 19 April 2007, Pages 93–106]. Pressure drop evolution, cake height distribution evolution, cake patches area distribution and their characterization using fractal analysis on different needle felts are presented here. It is observed that concavity of pressure drop curve for membrane coated needle felt is principally caused by presence of inhomogeneous cake area load whereas it is inherent for heat treated media. Presence of residual cake enhances the concavity of pressure drop at the start of filtration cycle. Patchy cleaning is observed only when jet pulse pressure is too low and unable to provide the necessary force to detach the cake. The border line is very sharp. Based on experiments with limestone dust and three types of needle felts, for the jet pulse pressure above 4 bar and filtration velocity below 50 mm/s, cake is detached completely except a thin residual layer (100–200 μm). Uniformity and smoothness of residual cake depends on the surface characteristics of the filter media. Cake height distribution of residual cake and newly formed cake during filtration prevails. The patch size analysis and fractal analysis reveal that residual cake grow in size (latterly) following regeneration initially on the base with edges smearing out, however, the cake heights are not leveled off. Fractal dimension of cake patches boundary falls in the range of 1–1.4 and depends on vertical position as well as time of filtration. Cake height measurements with Polyimide (PI) needle felts were hampered on account of its photosensitive nature. PMID:24415801
Membranes in Lithium Ion Batteries
Yang, Min; Hou, Junbo
2012-01-01
Lithium ion batteries have proven themselves the main choice of power sources for portable electronics. Besides consumer electronics, lithium ion batteries are also growing in popularity for military, electric vehicle, and aerospace applications. The present review attempts to summarize the knowledge about some selected membranes in lithium ion batteries. Based on the type of electrolyte used, literature concerning ceramic-glass and polymer solid ion conductors, microporous filter type separators and polymer gel based membranes is reviewed. PMID:24958286
Allen, Scott D.; Naik, Sanjeev
2017-08-22
The present invention provides, among other things, extruded blends of aliphatic polycarbonates and polyolefins. In one aspect, provided blends comprise aliphatic polycarbonates such as poly(propylene carbonate) and a lesser amount of a crystalline or semicrystalline polymer. In certain embodiments, provided blends are characterized in that they exhibit unexpected improvements in their elongation properties. In another aspect, the invention provides methods of making such materials and applications of the materials in applications such as the manufacture of consumer packaging materials.
Carbon nanotube-polymer nanocomposite infrared sensor.
Pradhan, Basudev; Setyowati, Kristina; Liu, Haiying; Waldeck, David H; Chen, Jian
2008-04-01
The infrared photoresponse in the electrical conductivity of single-walled carbon nanotubes (SWNTs) is dramatically enhanced by embedding SWNTs in an electrically and thermally insulating polymer matrix. The conductivity change in a 5 wt % SWNT-polycarbonate nanocomposite is significant (4.26%) and sharp upon infrared illumination in the air at room temperature. While the thermal effect predominates in the infrared photoresponse of a pure SWNT film, the photoeffect predominates in the infrared photoresponse of SWNT-polycarbonate nanocomposites.
Improvement program for polycarbonate capacitors. [hermetically sealed, and ac wound
NASA Technical Reports Server (NTRS)
Bailey, R. R.; Waterman, K. D.
1973-01-01
Hermetically sealed, wound, AC, polycarbonate capacitors incorporating design improvements recommended in a previous study were designed and built. A 5000 hour, 400 Hz ac life test was conducted using 384 of these capacitors to verify the adequacy of the design improvements. The improvements incorporated in the capacitors designed for this program eliminated the major cause of failure found in the preceding work, termination failure. A failure cause not present in the previous test became significant in this test with capacitors built from one lot of polycarbonate film. The samples from this lot accounted for 25 percent of the total test complement. Analyses of failed samples showed that the film had an excessive solvent content. This solvent problem was found in 37 of the total 46 failures which occurred in this test. The other nine were random failures resulting from causes such as seal leaks, foreign particles, and possibly wrinkles.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Brühwiler, Paul A.; Barbezat, Michel; Necola, Adly
2010-10-22
We report the quasistatic tensile and impact penetration properties (falling dart test) of injection-molded polycarbonate samples, as a function of multiwall carbon nanotube (MWNT) concentration (0.0-2.5%). The MWNT were incorporated by dilution of a commercial MWNT/polycarbonate masterbatch. The stiffness and quasistatic yield strength of the composites increased approximately linearly with MWNT concentration in all measurements. The energy absorbed in fracture was, however, a negative function of the MWNT concentration, and exhibited different dependencies in quasistatic and impact tests. Small-angle x-ray scattering (SAXS) showed that the dispersion of the MWNT was similar at all concentrations. The negative effects on energy absorptionmore » are attributed to agglomerates remaining in the samples, which were observed in optical microscopy and SAXS. Overall, there was a good correspondence between static and dynamic energy absorption.« less
Assessment of relative flammability and thermochemical properties of some thermoplastic materials
NASA Technical Reports Server (NTRS)
Kourtides, D. A.; Parker, J. A.
1978-01-01
The thermochemical and flammability characteristics of some typical thermoplastic materials currently in use and others being considered for use in aircraft interiors are described. The properties studied included (1) thermal mechanical properties such as glass transition and melt temperature, (2) changes in polymer enthalpy by differential scanning calorimetry, (3) thermogravimetric analysis in an anaerobic and oxidative environment, (4) oxygen index, (5) smoke evolution, (6) relative toxicity of the volatile products of pyrolysis, and (7) selected physical properties. The generic polymers which were evaluated included: acrylonitrile-butadiene-styrene, bisphenol A polycarbonate, bisphenol fluorenone carbonatedimethylsiloxane block polymer, phenolphthalein-bisphenol A polycarbonate, phenolphthalein polycarbonate, polyether sulfone, polyphenylene oxide, polyphenylene sulfide, polyaryl sulfone, chlorinated polyvinyl chloride homopolymer, polyvinyl fluoride, and polyvinylidene fluoride. Processing parameters including molding characteristics of some of the advanced polymers are described. Test results and relative rankings of some of the flammability, smoke and toxicity properties are presented.
Thermoplastic polymers for improved fire safety
NASA Technical Reports Server (NTRS)
Kourtides, D. A.; Parker, J. A.; Hilado, C. J.
1976-01-01
The thermochemical and flammability characteristics of some typical thermoplastic materials currently in use and others being considered for use in aircraft interiors are described. The properties studied included (1) thermomechanical properties such as glass transition and melt temperature, (2) changes in polymer enthalpy by differential scanning calorimetry, (3) thermogravimetric analysis in anaerobic and oxidative environments, (4) oxygen index, (5) smoke evolution, (6) relative toxicity of the volatile products of pyrolysis, and (7) selected physical properties. The generic polymers that were evaluated included: acrylonitrile butadiene styrene, bisphenol A polycarbonate, 9,9 bis (4-hydroxyphenyl) fluorene polycarbonatepoly (dimethyl siloxane) block polymer, phenolphthalein bisphenol A polycarbonate, phenolphthalein polycarbonate, polyether sulfone, polyphenylene oxide, polyphenylene sulfide, polyaryl sulfone, chlorinated polyvinyl chloride homopolymer, polyvinyl fluoride, and polyvinylidene fluoride. Processing parameters, including molding characteristics of some of the advanced polymers, are described. Test results and relative ranking of some of the flammability, smoke, and toxicity properties are presented.
Bio-based polycarbonate as synthetic toolbox
Hauenstein, O.; Agarwal, S.; Greiner, A.
2016-01-01
Completely bio-based poly(limonene carbonate) is a thermoplastic polymer, which can be synthesized by copolymerization of limonene oxide (derived from limonene, which is found in orange peel) and CO2. Poly(limonene carbonate) has one double bond per repeating unit that can be exploited for further chemical modifications. These chemical modifications allow the tuning of the properties of the aliphatic polycarbonate in nearly any direction. Here we show synthetic routes to demonstrate that poly(limonene carbonate) is the perfect green platform polymer, from which many functional materials can be derived. The relevant examples presented in this study are the transformation from an engineering thermoplastic into a rubber, addition of permanent antibacterial activity, hydrophilization and even pH-dependent water solubility of the polycarbonate. Finally, we show a synthetic route to yield the completely saturated counterpart that exhibits improved heat processability due to lower reactivity. PMID:27302694
Metal reduction at point-of-use filtration
NASA Astrophysics Data System (ADS)
Umeda, Toru; Daikoku, Shusaku; Varanasi, Rao; Tsuzuki, Shuichi
2016-03-01
We explored the metal removal efficiency of Nylon 6,6 and HDPE (High Density Polyethylene) membrane based filters, in solvents of varying degree of polarity such as Cyclohexanone and 70:30 mixture of PGME (Propylene Glycol Monomethyl Ether) and PGMEA (Propylene Glycol Monomethyl Ether), In all the solvents tested, Nylon 6,6 membrane filtration was found to be significantly more effective in removing metals than HDPE membranes, regardless of their respective membrane pore sizes. Hydrophilic interaction chromatography (HILIC) mechanism was invoked to rationalize metal removal efficiency dependence on solvent hydrophobicity.
NASA Astrophysics Data System (ADS)
Bobkowski, Romuald; Fedosejevs, Robert; Broughton, James N.
1999-06-01
A process has been developed for the purpose of fabricating 0.1 micron linewidth interdigital electrode patterns based on proximity x-ray lithography using a laser-plasma source. Such patterns are required in the manufacture of surface acoustic wave devices. The x-ray lithography was carried out using emission form a Cu plasma produced by a 15Hz, 248nm KrF excimer laser. A temporally multiplexed 50ps duration seed pulse was used to extract the KrF laser energy producing a train of several 50ps pulses spaced approximately 2ns apart within each output pulse. Each short pulse within the train gave the high focal spot intensity required to achieve high efficiency emission of keV x-rays. The first stage of the overall process involves the fabrication of x-ray mask patterns on 1 micron thick Si3N4 membranes using 3-beam lithography followed by gold electroplating. The second stage involves x-ray exposure of a chemically amplified resist through the mask patterns to produce interdigital electrode patterns with 0.1 micron linewidth. Helium background gas and thin polycarbonate/aluminum filters are employed to prevent debris particles from the laser-plasma source form reaching the exposed sample. A computer control system fires the laser and monitors the x-ray flux from the laser-plasma source to insure the desired x-ray exposure is achieved at the resist. In order to reduce diffusion effects in the chemically amplified resist during the post exposure bake the temperature had to be reduced from that normally used. Good reproduction of 0.1 micron linewidth patterns into the x-ray resist was obtained once the exposure parameters and post exposure bake were optimized. A compact exposure station using flowing helium at atmospheric pressure has also been developed for the process, alleviating the need for a vacuum chamber. The details of the overall process and the compact exposure station will be presented.
Xu, Huacheng; Guo, Laodong
2017-06-15
Dissolved organic matter (DOM) is ubiquitous in natural waters. The ecological role and environmental fate of DOM are highly related to the chemical composition and size distribution. To evaluate size-dependent DOM quantity and quality, water samples were collected from river, lake, and coastal marine environments and size fractionated through a series of micro- and ultra-filtrations with different membranes having different pore-sizes/cutoffs, including 0.7, 0.4, and 0.2 μm and 100, 10, 3, and 1 kDa. Abundance of dissolved organic carbon, total carbohydrates, chromophoric and fluorescent components in the filtrates decreased consistently with decreasing filter/membrane cutoffs, but with a rapid decline when the filter cutoff reached 3 kDa, showing an evident size-dependent DOM abundance and composition. About 70% of carbohydrates and 90% of humic- and protein-like components were measured in the <3 kDa fraction in freshwater samples, but these percentages were higher in the seawater sample. Spectroscopic properties of DOM, such as specific ultraviolet absorbance, spectral slope, and biological and humification indices also varied significantly with membrane cutoffs. In addition, different ultrafiltration membranes with the same manufacture-rated cutoff also gave rise to different DOM retention efficiencies and thus different colloidal abundances and size spectra. Thus, the size-dependent DOM properties were related to both sample types and membranes used. Our results here provide not only baseline data for filter pore-size selection when exploring DOM ecological and environmental roles, but also new insights into better understanding the physical definition of DOM and its size continuum in quantity and quality in aquatic environments. Copyright © 2017 Elsevier Ltd. All rights reserved.
Direct Exposure of Monolayers of Mammalian Cells to Airborne Pollutants in a Unique Culture System.
1981-02-01
of growth medium through the filter from the side opposite the cells so that they are nourished and kept moist. Growth medium perfusing through the...planting dispersed cells (Line V79, Chinese hamster lung fibroblasts) on the membrane filters and exposing to the test gas. The toxic effect was... Medium which perfuses through the filters is drawn off through the tubes at the rear wall of the chamber. The test gas enters at the left end of the
The effectiveness of a zirconium dioxide (ZrO2) membrane filter was evaluated for recycling a nonionic aqueous metal cleaning bath under real-world conditions. The pilot-scale study consisted of four 7- to 16-day filtration runs, each processed a portion of the cleaning bath duri...
Application of enhanced membrane bioreactor (eMBR) to treat dye wastewater.
Rondon, Hector; El-Cheikh, William; Boluarte, Ida Alicia Rodriguez; Chang, Chia-Yuan; Bagshaw, Steve; Farago, Leanne; Jegatheesan, Veeriah; Shu, Li
2015-05-01
An enhanced membrane bioreactor (eMBR) consisting of two anoxic bioreactors (ARs) followed by an aerated membrane bioreactor (AMBR), UV-unit and a granular activated carbon (GAC) filter was employed to treat 50-100 mg/L of remazol blue BR dye. The COD of the feed was 2334 mg/L and COD:TN:TP in the feed was 119:1.87:1. A feed flow rate of 5 L/d was maintained when the dye concentration was 50 mg/L; 10 L/d of return activated sludge was recirculated to each AR from the AMBR. Once the biological system is acclimatised, 95% of dye, 99% of COD, 97% of nitrogen and 73% of phosphorus were removed at a retention time of 74.4 h. When the effluent from the AMBR was drawn at a flux rate of 6.5 L/m(2)h, the trans-membrane pressure reached 40 kPa in every 10 days. AMBR effluent was passed through the UV-unit and GAC filter to remove the dye completely. Copyright © 2015 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Bautz, Mark W.; Kissel, S. E.; Ryu, K.; Suntharalingam, V.
2014-01-01
Silicon X-ray detectors require optical blocking filters to prevent out-of-band (UV, visible and near-IR) radiation from corrupting the X-ray signal. Traditionally, blocking filters have been deposited on thin, free-standing membranes suspended over the detector. Free-standing filters are fragile, however, and in past instruments have required heavy and complex vacuum housings to protect them from acoustic loads during ground operations and launch. A directly-deposited blocking filter greatly simplifies the instrument and in principle permits better soft X-ray detection efficiency than a traditional free-standing filter. Directly-deposited filters have flown in previous generation instruments (e.g. the XMM/Newton Reflection Grating Spectrometer) but none has yet been demonstrated on a modern, high-performance back-illuminated X-ray CCD. We report here on the status of our NASA-funded Strategic Astrophysics Technology program to demonstrate such filters.
Yang, Ssu-Han; Yang, Tsung-Ming; Lin, Hui-Ling; Tsai, Ying-Huang; Fang, Tien-Pei; Wan, Gwo-Hwa
2018-02-01
Few studies have evaluated the size distribution of inhaled and exhaled aerosolized drugs, or the effect of heated humidification on particle size and lung deposition. The present study evaluated these aspects of bronchodilator (salbutamol/ipratropium) delivery using a lung model in the absence and presence of heat and humidification. We positioned filters to collect and measure the initial drug, inhaled drug, and exhaled drug. Particle size distribution was evaluated using an 8-stage Marple personal cascade impactor with 0.2-μm polycarbonate filters. A greater inhaled drug mass was delivered using a vibrating mesh nebulizer (VMN) than by using a small volume nebulizer (SVN), when heated humidifiers were not employed. When heated and humidified medical gas was used, there was no significant difference between the inhaled drug mass delivered by the VMN and that delivered by the SVN. A significantly greater mass of inhaled 1.55-μm drug particles was produced by the VMN than with the SVN, under heated and humidified conditions. However, the mass median aerodynamic diameters (MMADs) of the aerosolized drug produced by the SVN and VMN did not differ significantly under the same conditions. The VMN produced more fine particles of salbutamol/ipratropium, and the drug particle size clearly increased in the presence of heat and humidification. Copyright © 2017 Elsevier Ltd. All rights reserved.
Systematic evaluation of dissolved lead sorption losses to particulate syringe filter materials.
Minning, Thomas; Lytle, Darren A; Pham, Maily; Kelty, Keith
2015-06-01
Distinguishing between soluble and particulate lead in drinking water is useful in understanding the mechanism of lead release and identifying remedial action. Typically, particulate lead is defined as the amount of lead removed by a 0.45-μm filter. Unfortunately, there is little guidance regarding selection of filter membrane material and little consideration to the possibility of the sorption of dissolved lead to the filter. The objective of this work was to examine the tendency of 0.45-μm syringe filter materials to adsorb lead. Tests were performed with water containing 40 and 24 μg/L soluble lead at pH 7 buffered with 50 mg C/L dissolved inorganic concentration (DIC). The amounts of lead sorbed greatly varied by filter, and only two filter types, polypropylene and mixed cellulose esters, performed well and are recommended. Great care must be taken in choosing a filter when filtering soluble lead and interpreting filter results.
[Thermal energy balance during hemodialysis: the role of the filter membrane].
Panzetta, G; Bianco, F; Galli, G; Ianche, M; Savoldi, S; Vianello, S; Vidi, E; Cicinato, P
2002-01-01
Body temperature tends to increase during conventional haemodialysis; this might interfere with normal cardiovascular response to dialytic ultrafiltration, thus facilitating the occurrence of symptomatic hypotension. Putative factors responsible for changes in thermal balance during haemodialysis include heat load from the dialysis bath, reduction in convective heat loss secondary to skin vessel vasoconstriction, heat overproduction due to central stimulation by bioincompatibility reactions to the filter membranes. The aim of the present study was twofold: to define thermal energy balance (ET) during dialysis and to investigate the effect of membrane bioincompatibility on energy balance We measured ET in 12 patients (9M, 3F) during two identical dialysis sessions, differing only in the membrane composition of the filters used: cuprophane 1.3- 1.6 mq and LF polysulphone 1.3- 1.6 mq. Thermal energy balance studies were performed by the Blood Temperature Monitor (Fresenius Medical Care) under conditions in which the core temperature of the patients was maintained unchanged from the start to the end of the dialysis procedure. Arterial blood temperatures were constant, while dialysate and venous blood temperatures progressively decreased (from 36.9 to 35.4 C and from 36.5 to 35.1 C for cuprophane; from 36.9 to 35.2 and from 36.9 to 35.1 for polysulphone membrane). Mean thermal energy transfer was negative (removal of energy from the patients to the extracorporeal circuit) with both filters, equal to 146 KJ with cuprophane and to 163 KJ with polysulphone. When a stepwise multiregression analysis was applied, hourly energy transfer (ET) was significantly and independently correlated with both ultrafiltration rate (UF=% b.w.) and heart rate changes (HR) according to the equation: ET= -92.03+41.29 UF+1.04 HR (p<0.0003). Conclusions. In this study we present experimental evidence that increased body temperature during dialysis is not caused by heat load from the dialysis bath, nor by heat over production secondary to bioincompatibility reactions. Consequently, haemodynamic responses to dialytic ultrafiltration may be regarded as the main regulatory factor of thermal balance.
Wu, Zhihong; Li, Shuning; Wang, Ningli; Liu, Wanshun; Liu, Wen
2013-01-01
To investigate the potential usage of biological delivery membranes containing mitomycin C (MMC) or 5-fluorouracil (5-FU) in the construction of glaucoma-filtering blebs, and to evaluate their safety and efficacy. Chitosan was selected as the biological membrane carrier to prepare sustained-released membranes. Twelve micrograms of 5-FU or MMC was covalently conjugated onto the membranes by solvent volatilization. Rabbits underwent glaucoma filtration surgery and were randomly allocated into one of the four treatment regimens: glaucoma filtration operation with no implantation of chitosan membrane group (as control), drug-free chitosan membrane implantation group (blank/placebo group), membrane containing 5-FU treatment group (5-FU group), and membrane containing MMC treatment group (MMC group). Each group consisted of 12 rabbits. Intraocular pressure (IOP) was measured and evaluated over a 28-day period follow-up preoperatively, then after surgery on days 1, 3, 5, 7, 14, 21, and 28 by Tono-Pen. The aqueous humor was analyzed in each experimental and control groups at days 4, 6, 8, 10, 12, 14, 16, and 20 after operation. Bleb survival and anterior segment were examined with a slit lamp microscope and photographed simultaneously. Two rabbits from each group were killed on day 28 and eight eye samples obtained for histopathological study. Corneas and lenses were examined by transmission and scanning electron microscopy. Both 5-FU and MMC significantly prolonged bleb survival compared with control groups. The filtering bleb's survival period was significantly more prolonged in the MMC and 5-FU groups (maintained 14 days) than the other two groups (maintained 7 days). Significantly lower IOP was observed within the control, blank, and 5-FU groups after surgery on day 14 compared with that before operation, with F-values of 6.567, 11.426, and 13.467, respectively (P < 0.01). The most significant lower IOP was recorded in the MMC group on day 28 postoperation (F-value 26.866, P < 0.01). No obvious abnormalities were found in cornea or anterior lens capsule 28 days after surgery. The study provided evidence that 5-FU and MMC biological delivery membranes could significantly improve the outcome of filtering procedures, the survival of the bleb, and maintenance of lower IOP. MMC membrane is superior to 5-FU, with regard to the more effective reduction of IOP. The results indicated a safe and effective treatment strategy in glaucoma surgery.
Wu, Zhihong; Li, Shuning; Wang, Ningli; Liu, Wanshun; Liu, Wen
2013-01-01
Purpose To investigate the potential usage of biological delivery membranes containing mitomycin C (MMC) or 5-fluorouracil (5-FU) in the construction of glaucoma-filtering blebs, and to evaluate their safety and efficacy. Methods Chitosan was selected as the biological membrane carrier to prepare sustained-released membranes. Twelve micrograms of 5-FU or MMC was covalently conjugated onto the membranes by solvent volatilization. Rabbits underwent glaucoma filtration surgery and were randomly allocated into one of the four treatment regimens: glaucoma filtration operation with no implantation of chitosan membrane group (as control), drug-free chitosan membrane implantation group (blank/placebo group), membrane containing 5-FU treatment group (5-FU group), and membrane containing MMC treatment group (MMC group). Each group consisted of 12 rabbits. Intraocular pressure (IOP) was measured and evaluated over a 28-day period follow-up preoperatively, then after surgery on days 1, 3, 5, 7, 14, 21, and 28 by Tono-Pen. The aqueous humor was analyzed in each experimental and control groups at days 4, 6, 8, 10, 12, 14, 16, and 20 after operation. Bleb survival and anterior segment were examined with a slit lamp microscope and photographed simultaneously. Two rabbits from each group were killed on day 28 and eight eye samples obtained for histopathological study. Corneas and lenses were examined by transmission and scanning electron microscopy. Results Both 5-FU and MMC significantly prolonged bleb survival compared with control groups. The filtering bleb’s survival period was significantly more prolonged in the MMC and 5-FU groups (maintained 14 days) than the other two groups (maintained 7 days). Significantly lower IOP was observed within the control, blank, and 5-FU groups after surgery on day 14 compared with that before operation, with F-values of 6.567, 11.426, and 13.467, respectively (P < 0.01). The most significant lower IOP was recorded in the MMC group on day 28 postoperation (F-value 26.866, P < 0.01). No obvious abnormalities were found in cornea or anterior lens capsule 28 days after surgery. Conclusion The study provided evidence that 5-FU and MMC biological delivery membranes could significantly improve the outcome of filtering procedures, the survival of the bleb, and maintenance of lower IOP. MMC membrane is superior to 5-FU, with regard to the more effective reduction of IOP. The results indicated a safe and effective treatment strategy in glaucoma surgery. PMID:23576864
A simple novel device for air sampling by electrokinetic capture
Gordon, Julian; Gandhi, Prasanthi; Shekhawat, Gajendra; ...
2015-12-27
A variety of different sampling devices are currently available to acquire air samples for the study of the microbiome of the air. All have a degree of technical complexity that limits deployment. Here, we evaluate the use of a novel device, which has no technical complexity and is easily deployable. An air-cleaning device powered by electrokinetic propulsion has been adapted to provide a universal method for collecting samples of the aerobiome. Plasma-induced charge in aerosol particles causes propulsion to and capture on a counter-electrode. The flow of ions creates net bulk airflow, with no moving parts. A device and electrodemore » assembly have been re-designed from air-cleaning technology to provide an average air flow of 120 lpm. This compares favorably with current air sampling devices based on physical air pumping. Capture efficiency was determined by comparison with a 0.4 μm polycarbonate reference filter, using fluorescent latex particles in a controlled environment chamber. Performance was compared with the same reference filter method in field studies in three different environments. For 23 common fungal species by quantitative polymerase chain reaction (qPCR), there was 100 % sensitivity and apparent specificity of 87%, with the reference filter taken as “gold standard.” Further, bacterial analysis of 16S RNA by amplicon sequencing showed equivalent community structure captured by the electrokinetic device and the reference filter. Unlike other current air sampling methods, capture of particles is determined by charge and so is not controlled by particle mass. We analyzed particle sizes captured from air, without regard to specific analyte by atomic force microscopy: particles at least as low as 100 nM could be captured from ambient air. This work introduces a very simple plug-and-play device that can sample air at a high-volume flow rate with no moving parts and collect particles down to the sub-micron range. In conclusion, the performance of the device is substantially equivalent to capture by pumping through a filter for microbiome analysis by quantitative PCR and amplicon sequencing.« less
A simple novel device for air sampling by electrokinetic capture
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gordon, Julian; Gandhi, Prasanthi; Shekhawat, Gajendra
A variety of different sampling devices are currently available to acquire air samples for the study of the microbiome of the air. All have a degree of technical complexity that limits deployment. Here, we evaluate the use of a novel device, which has no technical complexity and is easily deployable. An air-cleaning device powered by electrokinetic propulsion has been adapted to provide a universal method for collecting samples of the aerobiome. Plasma-induced charge in aerosol particles causes propulsion to and capture on a counter-electrode. The flow of ions creates net bulk airflow, with no moving parts. A device and electrodemore » assembly have been re-designed from air-cleaning technology to provide an average air flow of 120 lpm. This compares favorably with current air sampling devices based on physical air pumping. Capture efficiency was determined by comparison with a 0.4 μm polycarbonate reference filter, using fluorescent latex particles in a controlled environment chamber. Performance was compared with the same reference filter method in field studies in three different environments. For 23 common fungal species by quantitative polymerase chain reaction (qPCR), there was 100 % sensitivity and apparent specificity of 87%, with the reference filter taken as “gold standard.” Further, bacterial analysis of 16S RNA by amplicon sequencing showed equivalent community structure captured by the electrokinetic device and the reference filter. Unlike other current air sampling methods, capture of particles is determined by charge and so is not controlled by particle mass. We analyzed particle sizes captured from air, without regard to specific analyte by atomic force microscopy: particles at least as low as 100 nM could be captured from ambient air. This work introduces a very simple plug-and-play device that can sample air at a high-volume flow rate with no moving parts and collect particles down to the sub-micron range. In conclusion, the performance of the device is substantially equivalent to capture by pumping through a filter for microbiome analysis by quantitative PCR and amplicon sequencing.« less
A simple novel device for air sampling by electrokinetic capture.
Gordon, Julian; Gandhi, Prasanthi; Shekhawat, Gajendra; Frazier, Angel; Hampton-Marcell, Jarrad; Gilbert, Jack A
2015-12-27
A variety of different sampling devices are currently available to acquire air samples for the study of the microbiome of the air. All have a degree of technical complexity that limits deployment. Here, we evaluate the use of a novel device, which has no technical complexity and is easily deployable. An air-cleaning device powered by electrokinetic propulsion has been adapted to provide a universal method for collecting samples of the aerobiome. Plasma-induced charge in aerosol particles causes propulsion to and capture on a counter-electrode. The flow of ions creates net bulk airflow, with no moving parts. A device and electrode assembly have been re-designed from air-cleaning technology to provide an average air flow of 120 lpm. This compares favorably with current air sampling devices based on physical air pumping. Capture efficiency was determined by comparison with a 0.4 μm polycarbonate reference filter, using fluorescent latex particles in a controlled environment chamber. Performance was compared with the same reference filter method in field studies in three different environments. For 23 common fungal species by quantitative polymerase chain reaction (qPCR), there was 100 % sensitivity and apparent specificity of 87 %, with the reference filter taken as "gold standard." Further, bacterial analysis of 16S RNA by amplicon sequencing showed equivalent community structure captured by the electrokinetic device and the reference filter. Unlike other current air sampling methods, capture of particles is determined by charge and so is not controlled by particle mass. We analyzed particle sizes captured from air, without regard to specific analyte by atomic force microscopy: particles at least as low as 100 nM could be captured from ambient air. This work introduces a very simple plug-and-play device that can sample air at a high-volume flow rate with no moving parts and collect particles down to the sub-micron range. The performance of the device is substantially equivalent to capture by pumping through a filter for microbiome analysis by quantitative PCR and amplicon sequencing.
[Method for concentration determination of mineral-oil fog in the air of workplace].
Xu, Min; Zhang, Yu-Zeng; Liu, Shi-Feng
2008-05-01
To study the method of concentration determination of mineral-oil fog in the air of workplace. Four filter films such as synthetic fabric filter film, beta glass fiber filter film, chronic filter paper and microporous film were used in this study. Two kinds of dust samplers were used to collect the sample, one sampling at fast flow rate in a short time and the other sampling at slow flow rate with long duration. Subsequently, the filter membrane was weighed with electronic analytical balance. According to sampling efficiency and incremental size, the adsorbent ability of four different filter membranes was compared. When the flow rate was between 10 approximately 20 L/min and the sampling time was between 10 approximately 15 min, the average sampling efficiency of synthetic fabric filter film was 95.61% and the increased weight ranged from 0.87 to 2.60 mg. When the flow rate was between 10 approximately 20 L/min and sampling time was between 10 approximately 15 min, the average sampling efficiency of beta glass fiber filter film was 97.57% and the increased weight was 0.75 approximately 2.47 mg. When the flow rate was between 5 approximately 10 L/min and the sampling time between 10 approximately 20 min, the average sampling efficiency of chronic filter paper and microporous film was 48.94% and 63.15%, respectively and the increased weight was 0.75 approximately 2.15 mg and 0.23 approximately 0.85 mg, respectively. When the flow rate was 3.5 L/min and the sampling time was between 100 approximately 166 min, the average sampling efficiency of filter film were 94.44% and 93.45%, respectively and the average increased weight was 1.28 mg for beta glass fiber filter film and 0.78 mg for beta glass fiber filter film and synthetic fabric synthetic fabric filter film. The average sampling efficiency of chronic filter paper and microporous film were 37.65% and 88.21%, respectively. The average increased weight was 4.30 mg and 1.23 mg, respectively. Sampling with synthetic fabric filter film and beta glass fiber filter film is credible, accurate, simple and feasible for determination of the concentration of mineral-oil fog in workplaces.
Winter, Joerg; Bérubé, Pierre
2017-01-01
Nanofiltration (NF) and tight ultrafiltration (tight UF) membranes are a viable treatment option for high quality drinking water production from sources with high concentrations of contaminants. To date, there is limited knowledge regarding the contribution of concentration polarization (CP) and fouling to the increase in resistance during filtration of natural organic matter (NOM) with NF and tight UF. Filtration tests were conducted with NF and tight UF membranes with molecular weight cut offs (MWCOs) of 300, 2000 and 8000 Da, and model raw waters containing different constituents of NOM. When filtering model raw waters containing high concentrations of polysaccharides (i.e., higher molecular weight NOM), the increase in resistance was dominated by fouling. When filtering model raw waters containing humic substances (i.e., lower molecular weight NOM), the increase in filtration resistance was dominated by CP. The results indicate that low MWCO membranes are better suited for NOM removal, because most of the NOM in surface waters consist mainly of humic substances, which were only effectively rejected by the lower MWCO membranes. However, when humic substances are effectively rejected, CP can become extensive, leading to a significant increase in filtration resistance by the formation of a cake/gel layer at the membrane surface. For this reason, cross-flow operation, which reduces CP, is recommended. PMID:28671604
Effect of pyrolysis temperature and air flow on toxicity of gases from a polycarbonate polymer
NASA Technical Reports Server (NTRS)
Hilado, C. J.; Brick, V. E.; Brauer, D. P.
1978-01-01
A polycarbonate polymer was evaluated for toxicity of pyrolysis gases generated at various temperatures without forced air flow and with 1 L/min air flow, using the toxicity screening test method developed at the University of San Francisco. Time to various animal responses decreased with increasing pyrolysis temperature over the range from 500 C to 800 C. There appeared to be no significant toxic effects at 400 C and lower temperatures.
The influence of cosmic radiation on the properties of different polymers
NASA Astrophysics Data System (ADS)
Major, Andrea Adamne; Boja, David
2017-10-01
During our research we investigated the influence of cosmic radiation on the properties of different polymers. Polypropylene, polyamide 6.6 and polycarbonate were used as raw materials. Test pieces were injection molded. The test pieces were "flying" at different heights (on Earth, at 5500 m, at 12000 m). Thermal properties were investigated: DSC and TGA. We found that cosmic relay influences change in the thermal properties of polypropylene, polyamide 6.6 and polycarbonate.
Stability of Atmospheric-Pressure Plasma Induced Changes on Polycarbonate Surfaces
NASA Technical Reports Server (NTRS)
Sharma, Rajesh; Holcomb, Edward; Trigwell, Steve
2006-01-01
Polycarbonate films are subjected to plasma treatment in a number of applications such as improving adhesion between polycarbonate and silicon alloy in protective and optical coatings. The changes in surface chemistry due to plasma treatment have tendency to revert back. Thus stability of the plasma induced changes on polymer surfaces over desired time period is very important. The objective of this study was to examine the effect of ageing on atmospheric pressure helium-plasma treated polycarbonate (PC) sample as a function of treatment time. The ageing effects were studied over a period of 10 days. The samples were plasma treated for 0.5, 2, 5 and 10 minutes. Contact angle measurements were made to study surface energy changes. Modification of surface chemical structure was examined using, X-ray Photoelectron Spectroscopy (XPS). Contact angle measurements on untreated and plasma treated surfaces were made immediately, 24, 48, 72 and 96 hrs after treatment. Contact angle decreased from 93 deg for untreated sample to 30 deg for sample plasma treated for 10 minutes. After 10 days the contact angles for the 10 minute plasma treated sample increased to 67 deg, but it never reverted back to that of untreated surface. Similarly the O/C ratio increased from 0.136 for untreated sample to 0.321 for 10 minute plasma treated sample indication increase in surface energy.
Chen, Wei; Meng, Fenghua; Cheng, Ru; Deng, Chao; Feijen, Jan; Zhong, Zhiyuan
2014-09-28
Biodegradable polymeric nanocarriers are one of the most promising systems for targeted and controlled drug and gene delivery. They have shown several unique advantages such as excellent biocompatibility, prolonged circulation time, passive tumor targeting via the enhanced permeability and retention (EPR) effect, and degradation in vivo into nontoxic products after completing their tasks. The current biodegradable drug and gene delivery systems exhibit, however, typically low in vivo therapeutic efficacy, due to issues of low loading capacity, inadequate in vivo stability, premature cargo release, poor uptake by target cells, and slow release of therapeutics inside tumor cells. To overcome these problems, a variety of advanced drug and gene delivery systems has recently been designed and developed based on functional biodegradable polycarbonates and copolymers. Notably, polycarbonates and copolymers with diverse functionalities such as hydroxyl, carboxyl, amine, alkene, alkyne, halogen, azido, acryloyl, vinyl sulfone, pyridyldisulfide, and saccharide, could be readily obtained by controlled ring-opening polymerization. In this paper, we give an overview on design concepts and recent developments of functional polycarbonate-based nanocarriers including stimuli-sensitive, photo-crosslinkable, or active targeting polymeric micelles, polymersomes and polyplexes for enhanced drug and gene delivery in vitro and in vivo. These multifunctional biodegradable nanosystems might be eventually developed for safe and efficient cancer chemotherapy and gene therapy. Copyright © 2014 Elsevier B.V. All rights reserved.
Kinnarinen, Teemu; Lubieniecki, Boguslaw; Holliday, Lloyd; Helsto, Jaakko-Juhani; Häkkinen, Antti
2015-03-01
Dry cake disposal is the preferred technique for the disposal of bauxite residue, when considering environmental issues together with possible future utilisation of the solids. In order to perform dry cake disposal in an economical way, the deliquoring of the residue must be carried out efficiently, and it is also important to wash the obtained solids well to minimise the amount of soluble soda within the solids. The study presented in this article aims at detecting the most important variables influencing the deliquoring and washing of bauxite residue, performed with a horizontal membrane filter press and by determining the optimal washing conditions. The results obtained from pilot-scale experiments are evaluated by considering the properties of the solids, for instance, the residual alkali and aluminium content, as well as the consumption of wash liquid. Two different cake washing techniques, namely classic washing and channel washing, are also used and their performances compared. The results show that cake washing can be performed successfully in a horizontal membrane filter press, and significant improvements in the recovery of alkali and aluminium can be achieved compared with pressure filtration carried out without washing, or especially compared with the more traditionally used vacuum filtration. © The Author(s) 2015.
de Freitas, Normanda L; Gonçalves, José A S; Innocentini, Murilo D M; Coury, José R
2006-08-25
The performance of double-layered ceramic filters for aerosol filtration at high temperatures was evaluated in this work. The filtering structure was composed of two layers: a thin granular membrane deposited on a reticulate ceramic support of high porosity. The goal was to minimize the high pressure drop inherent of granular structures, without decreasing their high collection efficiency for small particles. The reticulate support was developed using the technique of ceramic replication of polyurethane foam substrates of 45 and 75 pores per inch (ppi). The filtering membrane was prepared by depositing a thin layer of granular alumina-clay paste on one face of the support. Filters had their permeability and fractional collection efficiency analyzed for filtration of an airborne suspension of phosphatic rock in temperatures ranging from ambient to 700 degrees C. Results revealed that collection efficiency decreased with gas temperature and was enhanced with filtration time. Also, the support layer influenced the collection efficiency: the 75 ppi support was more effective than the 45 ppi. Particle collection efficiency dropped considerably for particles below 2 microm in diameter. The maximum collection occurred for particle diameters of approximately 3 microm, and decreased again for diameters between 4 and 8 microm. Such trend was successfully represented by the proposed correlation, which is based on the classical mechanisms acting on particle collection. Inertial impaction seems to be the predominant collection mechanism, with particle bouncing/re-entrainment acting as detachment mechanisms.
Hiebl, Bernhard; Lützow, Karola; Lange, Maik; Jung, Friedrich; Seifert, Barbara; Klein, Frank; Weigel, Thomas; Kratz, Karl; Lendlein, Andreas
2010-07-01
Most polymers used in clinical applications today are materials that have been developed originally for application areas other than biomedicine. Testing the cell- and tissue-compatibility of novel materials in vitro and in vivo is of key importance for the approval of medical devices and is regulated according to the Council Directive 93/42/EEC of the European communities concerning medical devices. In the standardized testing methods the testing sample is placed in commercially available cell culture plates, which are often made from polystyrene. Thus not only the testing sample itself influences cell behavior but also the culture vessel material. In order to exclude this influence, a new system for cell testing will be presented allowing a more precise and systematic investigation by preparing tailored inserts which are made of the testing material. Inserts prepared from polystyrene, polycarbonate and poly(ether imide) were tested for their cytotoxity and cell adherence. Furthermore a proof of principle concerning the preparation of inserts with a membrane-like surface structure and its surface modification was established. Physicochemical investigations revealed a similar morphology and showed to be very similar to the findings to analogous preparations and modifications of flat-sheet membranes. Copyright (c) 2010 Elsevier B.V. All rights reserved.
Detection and cultivation of circulating tumor cells in malignant pleural mesothelioma.
Bobek, Vladimir; Kacprzak, Grzegorz; Rzechonek, Adam; Kolostova, Katarina
2014-05-01
Malignant pleural mesothelioma (MPM) is an aggressive disease with very poor prognosis which tends to affect older patients. Progress in the management of this group of patients has been limited by the rarity of the disease and hence, difficulty in conducting randomized trials. The vast majority of cancer deaths occur due to metastasis of the primary tumor to distant sites via circulating tumor cells (CTCs) in the circulation. CTCs are extremely rare and limits in technology used to capture these cells hamper our complete understanding over the metastatic process. In the present study we present a new method for detection and cultivation of CTCs isolated from peripheral blood of MPM patients. Patients with diagnosed MPM were enrolled into this study. A size-based separation method for viable CTC enrichment from unclothed peripheral blood has been introduced; MetaCell. The size-based enrichment process was based on filtration of peripheral blood (PB) through porous polycarbonate membrane. The separated CTCs are cultured on the membrane in vitro under standard cancer cell culture conditions and observed by an inverted microscope. The reported methodology allows for quick and easy enrichment of CTCs and their cultivation. The cultivated cells can be used for next specification of gene expression and histological/biological specificity of concrete mesothelioma.
Tritium labeling of organic compounds deposited on porous structures
Ehrenkaufer, Richard L. E.; Wolf, Alfred P.; Hembree, Wylie C.
1979-01-01
An improved process for labeling organic compounds with tritium is carried out by depositing the selected compound on the extensive surface of a porous structure such as a membrane filter and exposing the membrane containing the compound to tritium gas activated by the microwave discharge technique. The labeled compound is then recovered from the porous structure.
Buntner, D; Spanjers, H; van Lier, J B
2014-03-15
The objective of the present study was to evaluate the impact of excess aerobic sludge on the specific methanogenic activity (SMA), in order to establish the maximum allowable aerobic sludge loading. In batch tests, different ratios of aerobic sludge to anaerobic inoculum were used, i.e. 0.03, 0.05, 0.10 and 0.15, showing that low ratios led to an increased SMA. However, the ratio 0.15 caused more than 20% SMA decrease. In addition to the SMA tests, the potential influence of biopolymers and extracellular substances, that are generated as a result of excess aerobic sludge hydrolysis, on membrane performance was determined by assessing the fouling potential of the liquid broth, taking into account parameters such as specific resistance to filtration (SRF) and supernatant filterability (SF). Addition of aerobic sludge to the anaerobic biomass resulted in a high membrane fouling potential. The increase in biopolymers could be ascribed to aerobic sludge hydrolysis. A clear positive correlation between the concentration of the colloidal fraction of biopolymer clusters (cBPC) and the SRF was observed and a negative correlation between the cBPC and the SF measured at the end of the above described SMA tests. The latter implies that sludge filtration resistance increases when more aerobic sludge is hydrolyzed, and thus more cBPC is released. During AnMBR operation, proteins significantly contributed to sludge filterability decrease expressed as SRF and SF, whereas the carbohydrate fraction of SMP was of less importance due to low concentrations. On the contrary, carbohydrates seemed to improve filterability and diminish SRF of the sludge. Albeit, cBPC increase caused an increase in mean TMP during the AnMBR operation, confirming that cBPC is positively correlated to membrane fouling. Copyright © 2013 Elsevier Ltd. All rights reserved.
Skougstad, M.W.; Scarbro, G.F.
1968-01-01
A readily portable, all plastic, pressure filtration unit is described which greatly facilitates rapid micropore membrane field filtration of up to several liters of water with a minimum risk of inorganic chemical alteration or contamination of the sample. The unit accommodates standard 10.2-cm. (4-inch) diameter filters. The storage and carrying case serves as a convenient filter stand for both field and laboratory use.
Judkins, Roddie R [Knoxville, TN
2009-02-03
A water filter includes a porous support characterized by a mean porosity in the range of 20 to 50% and a mean pore size of 2 to 5 .mu.m; and a carbon filter membrane disposed thereon which is characterized by a mean particle size of no more than 50 .mu.m and a mean pore size of no more than 7.2 .mu.m.
Operation of polycarbonate projectiles in the ram accelerator
NASA Astrophysics Data System (ADS)
Elder, Timothy
The ram accelerator is a hypervelocity launcher with direct space launch applications in which a sub-caliber projectile, analogous to the center-body of a ramjet engine, flies through fuel and oxidizer that have been premixed in a tube. Shock interactions in the tube ignite the propellant upon entrance of the projectile and the combustion travels with it, creating thrust on the projectile by stabilizing a high pressure region of gas behind it. Conventional ram accelerator projectiles consist of aluminum, magnesium, or titanium nosecones and bodies. An experimental program has been undertaken to determine the performance of polycarbonate projectiles in ram accelerator operation. Experimentation using polycarbonate projectiles has been divided into two series: determining the lower limit for starting velocity (i.e., less than 1100 m/s) and investigating the upper velocity limit. To investigate the influence of body length and starting velocity, a newly developed "combustion gun" was used to launch projectiles to their initial velocities. The combustion gun uses 3-6 m of ram accelerator test section as a breech and 4-6 m of the ram accelerator test section as a launch tube. A fuel-oxidizer mix is combusted in the breech using a spark plug or electric match and bursts a diaphragm, accelerating the ram projectile to its entrance velocity. The combustion gun can be operated at modest fill pressures (20 bar) but can only launch to relatively low velocities (approximately 1000 m/s) without destroying the projectile and obturator upon launch. Projectiles were successfully started at entrance velocities as low as 810 m/s and projectile body lengths as long as 91 mm were used. The tests investigating the upper Mach number limits of polycarbonate projectiles used the conventional single-stage light-gas gun because of its ability to reach higher velocities with a lower acceleration launch. It was determined that polycarbonate projectiles have an upper velocity limit in the range of 1500-1550 m/s which is lower than that of magnesium projectiles.
Zemiti, Nabil; Caravaca Mora, Oscar; Subsol, Gérard; Captier, Guillaume; Lebrun, Renaud; Crampette, Louis; Mondain, Michel; Gilles, Benjamin
2017-01-01
Introduction Endoscopic skull base surgery allows minimal invasive therapy through the nostrils to treat infectious or tumorous diseases. Surgical and anatomical education in this field is limited by the lack of validated training models in terms of geometric and mechanical accuracy. We choose to evaluate several consumer-grade materials to create a patient-specific 3D-printed skull base model for anatomical learning and surgical training. Methods Four 3D-printed consumer-grade materials were compared to human cadaver bone: calcium sulfate hemihydrate (named Multicolor), polyamide, resin and polycarbonate. We compared the geometric accuracy, forces required to break thin walls of materials and forces required during drilling. Results All materials had an acceptable global geometric accuracy (from 0.083mm to 0.203mm of global error). Local accuracy was better in polycarbonate (0.09mm) and polyamide (0.15mm) than in Multicolor (0.90mm) and resin (0.86mm). Resin and polyamide thin walls were not broken at 200N. Forces needed to break Multicolor thin walls were 1.6–3.5 times higher than in bone. For polycarbonate, forces applied were 1.6–2.5 times higher. Polycarbonate had a mode of fracture similar to the cadaver bone. Forces applied on materials during drilling followed a normal distribution except for the polyamide which was melted. Energy spent during drilling was respectively 1.6 and 2.6 times higher on bone than on PC and Multicolor. Conclusion Polycarbonate is a good substitute of human cadaver bone for skull base surgery simulation. Thanks to short lead times and reasonable production costs, patient-specific 3D printed models can be used in clinical practice for pre-operative training, improving patient safety. PMID:29252993
Chen, Gaosong; Hai, Jun; Wang, Hao; Liu, Weisheng; Chen, Fengjuan; Wang, Baodui
2017-03-02
Nowadays, the development of a multifunction system for the simultaneous multiple signal amplification detection and fast removal of Hg 2+ remains a major challenge. Herein, we for the first time used gold nanoparticles (Au NPs) and the corresponding filter membrane as chemosensors and adsorbents for dual signal amplification detection and fast removal of Hg 2+ . Such a system was based on the formation of gold amalgam and a gold amalgam-based reaction between rhodamine B (RhB) and NaBH 4 with fluorescence and colorimetric sensing functions. When the gold amalgam catalyzes the reduction of RhB, the red color and orange fluorescence of RhB gradually changed to colorless by switching the amount of Hg 2+ deposited on 13 nm Au NPs. The detection limit of the fluorescence assay and colorimetric assay is 1.16 nM and 2.54 nM for Hg 2+ , respectively. Interestingly, the color and fluorescence of RhB could be recovered when the above colorless reaction solution was exposed to air for about 2 hours. Taking advantage of the above optical phenomenon, a recyclable paper-based sensor has been developed by immobilizing the Au NPs and RhB dye on filter paper and has been successfully used for detection of Hg 2+ in real water samples. In addition, the filter membrane immobilized Au NPs could allow fast removal of mercury ions in Yellow river water and tap water with the removal efficiency close to 99%.
2014-01-01
We report on the successful integration of low-cost, conformal, and versatile atomic layer deposited (ALD) dielectric in Ni–Al2O3–Co magnetic tunnel junctions (MTJs) where the Ni is coated with a spin-filtering graphene membrane. The ALD tunnel barriers, as thin as 0.6 nm, are grown layer-by-layer in a simple, low-vacuum, ozone-based process, which yields high-quality electron-transport barriers as revealed by tunneling characterization. Even under these relaxed conditions, including air exposure of the interfaces, a significant tunnel magnetoresistance is measured highlighting the robustness of the process. The spin-filtering effect of graphene is enhanced, leading to an almost fully inversed spin polarization for the Ni electrode of −42%. This unlocks the potential of ALD for spintronics with conformal, layer-by-layer control of tunnel barriers in magnetic tunnel junctions toward low-cost fabrication and down-scaling of tunnel resistances. PMID:24988469
Active Mechanisms of Vibration Encoding and Frequency Filtering in Central Mechanosensory Neurons.
Azevedo, Anthony W; Wilson, Rachel I
2017-10-11
To better understand biophysical mechanisms of mechanosensory processing, we investigated two cell types in the Drosophila brain (A2 and B1 cells) that are postsynaptic to antennal vibration receptors. A2 cells receive excitatory synaptic currents in response to both directions of movement: thus, twice per vibration cycle. The membrane acts as a low-pass filter, so that voltage and spiking mainly track the vibration envelope rather than individual cycles. By contrast, B1 cells are excited by only forward or backward movement, meaning they are sensitive to vibration phase. They receive oscillatory synaptic currents at the stimulus frequency, and they bandpass filter these inputs to favor specific frequencies. Different cells prefer different frequencies, due to differences in their voltage-gated conductances. Both Na + and K + conductances suppress low-frequency synaptic inputs, so cells with larger voltage-gated conductances prefer higher frequencies. These results illustrate how membrane properties and voltage-gated conductances can extract distinct stimulus features into parallel channels. Copyright © 2017 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Devathasan, D.; Trebych, K.; Karanassios, Vassili
2013-05-01
A 3d-printed, solar-powered, battery-operated, atmospheric-pressure, self-igniting microplasma the size of a sugar-cube has been used as light source to document the Ultra Violet (UV) and visible transmission characteristics of differentthickness polycarbonate chips that are often used for microfluidic applications. The hybrid microplasma chip was fitted with a quartz plate because quartz is transparent to UV.
Ceramic membrane development in NGK
NASA Astrophysics Data System (ADS)
Araki, Kiyoshi; Sakai, Hitoshi
2011-05-01
NGK Insulators, Ltd. was established in 1919 to manufacture the electric porcelain insulators for power transmission lines. Since then, our business has grown as one of the world-leading ceramics manufacturing companies and currently supply with the various environmentally-benign ceramic products to worldwide. In this paper, ceramic membrane development in NGK is described in detail. We have been selling ceramic microfiltration (MF) membranes and ultra-filtration (UF) membranes for many years to be used for solid/liquid separation in various fields such as pharmaceutical, chemical, food and semiconductor industries. In Corporate R&D, new ceramic membranes with sub-nanometer sized pores, which are fabricated on top of the membrane filters as support, are under development for gas and liquid/liquid separation processes.
All-in-One Nanowire-Decorated Multifunctional Membrane for Rapid Cell Lysis and Direct DNA Isolation
2015-01-01
This paper describes a handheld device that uses an all-in-one membrane for continuous mechanical cell lysis and rapid DNA isolation without the assistance of power sources, lysis reagents, and routine centrifugation. This nanowire-decorated multifunctional membrane was fabricated to isolate DNA by selective adsorption to silica surface immediately after disruption of nucleus membranes by ultrasharp tips of nanowires for a rapid cell lysis, and it can be directly assembled with commercial syringe filter holders. The membrane was fabricated by photoelectrochemical etching to create microchannel arrays followed by hydrothermal synthesis of nanowires and deposition of silica. The proposed membrane successfully purifies high-quality DNA within 5 min, whereas a commercial purification kit needs more than an hour. PMID:25420232
Pathan, Arif H K; Barash, Alexander; Tena, Lawrence B; Finger, Paul T
2018-01-01
To provide a clinical description of the long-term outcome of a 103 Pd plaque-irradiated ciliary body melanoma with extrascleral extension while attempting to preserve a subadjacent glaucoma filtering bleb. A 75-year-old woman with pseudoexfoliative glaucoma for 17 years, 16 years status post argon laser trabeculoplasty, and 15 years status post trabeculectomy in the left eye, was diagnosed with an ipsilateral ciliary body melanoma with visible extrascleral extension. Treatment involved insertion of a 103 Pd radioactive plaque over the functioning trabeculectomy, with removal 7 days later. At plaque insertion, amniotic membrane grafts were used to cover the plaque and protect the filtering site. The tumor was successfully treated without clinical evidence of harm to the filtering bleb, with resultant stable intraocular pressure. However, the patient developed blebitis 1.5 years later. Though it resolved with topical antibiotic therapy, the bleb became less succulent. Two years postoperatively, she developed a spontaneous hyphema that resolved after one injection of transscleral bevacizumab 1.25 mg. Her tumor continually regressed in thickness. Without additional glaucoma surgery, her intraocular pressure remained well-controlled on topical medications for 6 years. Ciliary body melanoma with minimal extrascleral extension beneath a functioning filtering bleb can be treated using radioactive plaque therapy. In this case, we were able to achieve both tumor regression and glaucoma control by covering the plaque with an amniotic membrane graft.
Interactions of trace metals with hydrogels and filter membranes used in DET and DGT techniques.
Garmo, Oyvind A; Davison, William; Zhang, Hao
2008-08-01
Equilibrium partitioning of trace metals between bulk solution and hydrogels/filter was studied. Under some conditions, trace metal concentrations were higher in the hydrogels or filter membranes compared to bulk solution (enrichment). In synthetic soft water, enrichment of cationic trace metals in polyacrylamide hydrogels decreased with increasing trace metal concentration. Enrichment was little affected by Ca and Mg in the concentration range typically encountered in natural freshwaters, indicating high affinity but low capacity binding of trace metals to solid structure in polyacrylamide gels. The apparent binding strength decreased in the sequence: Cu > Pb > Ni approximately to Cd approximately to Co and a low concentration of cationic Cu eliminated enrichment of weakly binding trace metal cations. The polyacrylamide gels also had an affinity for fulvic acid and/or its trace metal complexes. Enrichment of cationic Cd in agarose gel and hydrophilic polyethersulfone filter was independent of concentration (10 nM to 5 microM) but decreased with increasing Ca/ Mg concentration and ionic strength, suggesting that it is mainly due to electrostatic interactions. However, Cu and Pb were enriched even after equilibration in seawater, indicating that these metals additionally bind to sites within the agarose gel and filter. Compared to the polyacrylamide gels, agarose gel had a lower affinity for metal-fulvic complexes. Potential biases in measurements made with the diffusive equilibration in thin-films (DET) technique, identified by this work, are discussed.
NASA Astrophysics Data System (ADS)
Tian, Shili; Pan, Yuepeng; Wang, Jian; Wang, Yuesi
2016-11-01
Current science and policy requirements have focused attention on the need to expand and improve particulate matter (PM) sampling methods. To explore how sampling filter type affects artifacts in PM composition measurements, size-resolved particulate SO42-, NO3- and NH4+ (SNA) were measured on quartz fiber filters (QFF), glass fiber filters (GFF) and cellulose membranes (CM) concurrently in an urban area of Beijing on both clean and hazy days. The results showed that SNA concentrations in most of the size fractions exhibited the following patterns on different filters: CM > QFF > GFF for NH4+; GFF > QFF > CM for SO42-; and GFF > CM > QFF for NO3-. The different patterns in coarse particles were mainly affected by filter acidity, and that in fine particles were mainly affected by hygroscopicity of the filters (especially in size fraction of 0.65-2.1 μm). Filter acidity and hygroscopicity also shifted the peaks of the annual mean size distributions of SNA on QFF from 0.43-0.65 μm on clean days to 0.65-1.1 μm on hazy days. However, this size shift was not as distinct for samples measured with CM and GFF. In addition, relative humidity (RH) and pollution levels are important factors that can enhance particulate size mode shifts of SNA on clean and hazy days. Consequently, the annual mean size distributions of SNA had maxima at 0.65-1.1 μm for QFF samples and 0.43-0.65 μm for GFF and CM samples. Compared with NH4+ and SO42-, NO3- is more sensitive to RH and pollution levels, accordingly, the annual mean size distribution of NO3- exhibited peak at 0.65-1.1 μm for CM samples instead of 0.43-0.65 μm. These methodological uncertainties should be considered when quantifying the concentrations and size distributions of SNA under different RH and haze conditions.
Evaluation of membrane filter field monitors for microbiological air sampling
NASA Technical Reports Server (NTRS)
Fields, N. D.; Oxborrow, G. S.; Puleo, J. R.; Herring, C. M.
1974-01-01
Due to area constraints encountered in assembly and testing areas of spacecraft, the membrane filter field monitor (MF) and the National Aeronautics and Space Administration-accepted Reyniers slit air sampler were compared for recovery of airborne microbial contamination. The intramural air in a microbiological laboratory area and a clean room environment used for the assembly and testing of the Apollo spacecraft was studied. A significantly higher number of microorganisms was recovered by the Reyniers sampler. A high degree of consistency between the two sampling methods was shown by a regression analysis, with a correlation coefficient of 0.93. The MF samplers detected 79% of the concentration measured by the Reyniers slit samplers. The types of microorganisms identified from both sampling methods were similar.
Water Permeation Across Biological Membranes: Mechanism and Dynamics of Aquaporin-1 and GlpF
NASA Astrophysics Data System (ADS)
de Groot, Bert L.; Grubmüller, Helmut
2001-12-01
``Real time'' molecular dynamics simulations of water permeation through human aquaporin-1 (AQP1) and the bacterial glycerol facilitator GlpF are presented. We obtained time-resolved, atomic-resolution models of the permeation mechanism across these highly selective membrane channels. Both proteins act as two-stage filters: Conserved fingerprint [asparagine-proline-alanine (NPA)] motifs form a selectivity-determining region; a second (aromatic/arginine) region is proposed to function as a proton filter. Hydrophobic regions near the NPA motifs are rate-limiting water barriers. In AQP1, a fine-tuned water dipole rotation during passage is essential for water selectivity. In GlpF, a glycerol-mediated ``induced fit'' gating motion is proposed to generate selectivity for glycerol over water.
Barnard, James G; Kahn, David; Cetlin, David; Randolph, Theodore W; Carpenter, John F
2014-03-01
Filtration to remove viruses is one of the single most expensive steps in the production of mAb drug products. Therefore, virus filtration steps should be fully optimized, and any decline in flow rates warrants investigation into the causes of such membrane fouling. In the current study, it was found that freezing and thawing of a mAb bulk drug solution caused a substantial decrease in viral filter membrane flow rate. Freezing and thawing also caused formation of aggregates and particles across a broad size range, including particles that could be detected by microflow imaging (≥1 μm in size). However, removal of these particles offered little protection against flow rate decline during viral filtration. Further investigation revealed that trace amounts of aggregates (ca. 10⁻⁶ of the total mass of protein in solution) approximately 20-40 nm in size were primarily responsible for the observed membrane fouling. © 2014 Wiley Periodicals, Inc. and the American Pharmacists Association.
Li, Wen-Wei; Wang, Yun-Kun; Sheng, Guo-Ping; Gui, Yong-Xin; Yu, Lei; Xie, Tong-Qing; Yu, Han-Qing
2012-10-01
Conventional MBR has been mostly based on floc sludge and the use of costly microfiltration membranes. Here, a novel aerobic granule (AG)-mesh filter MBR (MMBR) process was developed for cost-effective wastewater treatment. During 32-day continuous operation, a predominance of granules was maintained in the system, and good filtration performance was achieved at a low trans-membrane pressure (TMP) of below 0.025 m. The granules showed a lower fouling propensity than sludge flocs, attributed to the formation of more porous biocake layer at mesh surface. A low-flux and low-TMP filtration favored a stable system operation. In addition, the reactor had high pollutant removal efficiencies, with a 91.4% chemical oxygen demand removal, 95.7% NH(4)(+) removal, and a low effluent turbidity of 4.1 NTU at the stable stage. This AG-MMBR process offers a promising technology for low-cost and efficient treatment of wastewaters. Copyright © 2012 Elsevier Ltd. All rights reserved.
Comparison of techniques for the detection of helminth ova in drinking water and wastewater.
Maya, C; Jimenez, B; Schwartzbrod, J
2006-02-01
Many countries use wastewater for irrigation. The World Health Organization established, as reuse guidelines, a maximum value of 1 helminth ovum/L for irrigation. Various techniques for enumerating helminth ova in water have been published. To determine the most adequate method for Mexico, four techniques were compared: the U.S. Environmental Protection Agency (U.S. EPA), membrane-filter, Leeds I, and Faust. Two types of water were used: drinking water and municipal wastewater effluent. Sensitivity, discrimination coefficients, precision, recovery efficiency, and cost were determined. In addition, several unseeded wastewater samples were analyzed. For drinking water, U.S. EPA and the membrane-filter techniques demonstrated comparable results; however, when wastewater was used, the membrane technique showed some deficiencies. Because the U.S. EPA technique may be used for samples with both high and low solids content, allows for the recovery of helminth ova with different specific gravities, and has the lowest total cost, it was selected as the best technique.
Gain and frequency tuning within the mouse cochlear apex
DOE Office of Scientific and Technical Information (OSTI.GOV)
Oghalai, John S.; Raphael, Patrick D.; Gao, Simon
Normal mammalian hearing requires cochlear outer hair cell active processes that amplify the traveling wave with high gain and sharp tuning, termed cochlear amplification. We have used optical coherence tomography to study cochlear amplification within the apical turn of the mouse cochlea. We measured not only classical basilar membrane vibratory tuning curves but also vibratory responses from the rest of the tissues that compose the organ of Corti. Basilar membrane tuning was sharp in live mice and broad in dead mice, whereas other regions of the organ of Corti demonstrated phase shifts consistent with additional filtering beyond that provided bymore » basilar membrane mechanics. We use these experimental data to support a conceptual framework of how cochlear amplification is tuned within the mouse cochlear apex. We will also study transgenic mice with targeted mutations that affect different biomechanical aspects of the organ of Corti in an effort to localize the underlying processes that produce this additional filtering.« less
NASA Astrophysics Data System (ADS)
Turneaure, Stefan; Zdanowicz, E.; Sinclair, N.; Graber, T.; Gupta, Y. M.
2015-06-01
Structural changes in shock compressed silicon were observed directly using time-resolved x-ray diffraction (XRD) measurements at the Dynamic Compression Sector at the Advanced Photon Source. The silicon samples were impacted by polycarbonate impactors accelerated to velocities greater than 5 km/s using a two-stage light gas gun resulting in impact stresses of about 25 GPa. The 23.5 keV synchrotron x-ray beam passed through the polycarbonate impactor, the silicon sample, and an x-ray window (polycarbonate or LiF) at an angle of 30 degrees relative to the impact plane. Four XRD frames (~ 100 ps snapshots) were obtained with 153.4 ns between frames near the time of impact. The XRD measurements indicate that in the peak shocked state, the silicon samples completely transformed to a high-pressure phase. XRD results for both shocked polycrystalline silicon and single crystal silicon will be presented and compared. Work supported by DOE/NNSA.
Li, Zhen; Yang, Jian; Ye, Heng; Ding, Mingming; Luo, Feng; Li, Jianshu; Li, Jiehua; Tan, Hong; Fu, Qiang
2018-06-11
The degradation behaviors including oxidation and hydrolysis of silicone modified polycarbonate urethanes were thoroughly investigated. These polyurethanes were based on polyhexamethylene carbonate (PHMC)/polydimethylsiloxane (PDMS) mixed macrodiols with molar ratio of PDMS ranging from 5% to 30%. It was proved that PDMS tended to migrate toward surface and even a small amount of PDMS could form a silicone-like surface. Macrophages-mediated oxidation process indicated that the PDMS surface layer was desirable to protect the fragile soft PHMC from the attack of degradative species. Hydrolysis process was probed in detail after immersing in boiling buffered water using combined analytical tools. Hydrolytically stable PDMS could act as protective shields for the bulk to hinder the chain scission of polycarbonate carbonyls whereas the hydrolysis of urethane linkages was less affected. Although the promoted phase separation at higher PDMS fractions lead to possible physical defects and mechanical compromise after degradation, simultaneously enhanced oxidation and hydrolysis resistance could be achieved for the polyurethanes with proper PDMS incorporation.
A Review of Membrane-Based Biosensors for Pathogen Detection
van den Hurk, Remko; Evoy, Stephane
2015-01-01
Biosensors are of increasing interest for the detection of bacterial pathogens in many applications such as human, animal and plant health, as well as food and water safety. Membranes and membrane-like structures have been integral part of several pathogen detection platforms. Such structures may serve as simple mechanical support, function as a part of the transduction mechanism, may be used to filter out or concentrate pathogens, and may be engineered to specifically house active proteins. This review focuses on membrane materials, their associated biosensing applications, chemical linking procedures, and transduction mechanisms. The sensitivity of membrane biosensors is discussed, and the state of the field is evaluated and summarized. PMID:26083229
Emissivity of freestanding membranes with thin metal coatings
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zwol, P. J. van, E-mail: Pieter-jan.van.zwol@asml.com; Vles, D. F.; Voorthuijzen, W. P.
Freestanding silicon nitride membranes with thicknesses down to a few tens of nanometers find use as TEM windows or soft X-ray spectral purity filters. As the thickness of a membrane decreases, emissivity vanishes, which limits radiative heat emission and resistance to heat loads. We show that thin metal layers with thicknesses in the order of 1 nm enhance the emissivity of thin membranes by two to three orders of magnitude close to the theoretical limit of 0.5. This considerably increases thermal load capacity of membranes in vacuum environments. Our experimental results are in line with classical theory in which we adaptmore » thickness dependent scattering terms in the Drude and Lorentz oscillators.« less
Fundamental and Applied Studies of Polymer Membranes
NASA Astrophysics Data System (ADS)
Imbrogno, Joseph
Four major areas have been studied in this research: 1) synthesizing novel monomers, e.g. chiral monomers, to produce new types of functionalized membranes for the biotechnology and pharmaceutical industries, 2) hydrophobic brush membranes for desalinating brackish water, sea water, and separating organics, 3) fundamental studies of water interactions at surfaces using sum frequency generation (SFG), and 4) discovering new surface chemistries that will control the growth and differentiation of stem cells. We have developed a novel synthesis method in order to increase the breadth of our high throughput screening library. This library was generated using maleimide chemistry to react a common methacrylate linker with a variety of different functions groups (R groups) in order to form new monomers that were grafted from the surface of PES ultrafiltration membranes. From this work, we discovered that the chirality of a membrane can affect performance when separating chiral feed streams. This effect was observed when filtering bovine serum albumin (BSA) and ovalbumin in a high salt phosphate buffered saline (PBS, 150 mM salt). The Phe grafted membranes showed a large difference in performance when filtering BSA with selectivity of 1.13 and 1.00 for (S) and (R) Phe, respectively. However, when filtering ovalbumin, the (S) and (R) modified surfaces showed selectivity of 2.06 and 2.31, respectively. The higher selectivity enantiomer switched for the two different proteins. Permeability when filtering BSA was 3.06 LMH kPa-1 and 4.31 LMH kPa -1 for (S)- and (R)- Phe, respectively, and 2.65 LMH kPa -1 and 2.10 LMH kPa-1 when filtering ovalbumin for (S)- and (R)- Phe, respectively. Additionally, these effects were no longer present when using a low salt phosphate buffer (PB, 10 mM salt). Since, to our knowledge, membrane chirality is not considered in current industrial systems, this discovery could have a large impact on the pharmaceutical and biotechnology industries. We have developed hydrophobic brush membranes that were able to selectively separate valuable organics (isobutanol) from water, while rejecting other undesirable species, such as enzymes, using pervaporation (PV). These membranes (grafted from nanofiltration (NF) support membranes) had a selectivity ˜1.5x higher than the current industrial standard, polydimethylsiloxane (PDMS), with alpha = 10.1 +/- 0.9 for our brush membranes and alpha = 6.7 +/- 0.1 for PDMS membranes. Since the mechanism of pervaporation is based on the solution diffusion (SD) model, these membranes may be used to desalinate water or fractionate gases since they are also based on the SD mechanism. We have discovered that hydrophobic brush membranes are able to reject monovalent salt ions. This type of membrane is analogous to carbon nanotubes (CNTs), which are believed to have extremely high water fluxes through them due to near frictionless flow caused by a lack of hydrogen bonding. Using these brush membranes we were able to achieve 42% monovalent (NaCl) salt rejection of simulated seawater (32,000 ppm salt). These membranes are easier to scale-up than current composite membranes produced using interfacial polymerization. We have been using SFG to study interfacial water on membrane surfaces. We believe that water interactions with the membrane surface and with the feed species, e.g. proteins, play a critical role during the fouling process. Relevant buffers, such as phosphate buffered saline (PBS) and phosphate buffer, contain ions that are known to restructure water at interfaces. Sum frequency generation spectroscopy (SFG) was used to characterize interfacial water structure at poly(ether sulfone) (PES) thin films in the presence of 0.01 M phosphate buffer (low salt) and 0.01 M phosphate buffered saline (high salt). Three model surfaces were studied: unmodified PES, hydrophobic alkane (C18) modified PES, and poly(ethylene glycol) (PEG) modified PES. In the presence of the low salt phosphate buffer (10 mM salt), phosphate anions were excluded from the PEG-modified PES film. This led to a charge separation between the phosphate anions and sodium cations, creating a surface potential which strongly ordered water molecules into the bulk. When using high salt PBS (138 mM salt) the sodium chloride ions screened this charge and reduced water ordering. Interestingly, this effect was the greatest for the PEG modified surface, with minor or no effects observed for the C18 modified PES and unmodified PES, respectively. Using our high throughput screening platform, we were able to determine that (N-[3-(dimethylamino)propyl] methacrylamide), DMAPMA, supported strong attachment and long-term self-renewal of mouse embryonic stem (ES) cells while preventing differentiation (maintaining pluripotency). After developing this platform, it was used to screen for a surface that could instead induce differentiation of bovine and human retinal pigment epithelium (RPE) cells while promoting cell growth. Several PEG based surfaces were able to induce cobblestone morphology of the RPE cells, which is indicative of differentiation. (Abstract shortened by UMI.).
Rotzetter, A C C; Kellenberger, C R; Schumacher, C M; Mora, C; Grass, R N; Loepfe, M; Luechinger, N A; Stark, W J
2013-11-13
A chemically active filtration membrane with incorporated lanthanum oxide nanoparticles enables the removal of bacteria and phosphate at the same time and thus provides a simple device for preparation of drinking water and subsequent safe storage without using any kind of disinfectants. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Failure mechanism of the polymer infiltration of carbon nanotube forests
NASA Astrophysics Data System (ADS)
Buchheim, Jakob; Park, Hyung Gyu
2016-11-01
Polymer melt infiltration is one of the feasible methods for manufacturing filter membranes out of carbon nanotubes (CNTs) on large scales. Practically, however, its process suffers from low yields, and the mechanism behind this failure is rather poorly understood. Here, we investigate a failure mechanism of polymer melt infiltration of vertical aligned (VA-) CNTs. In penetrating the VA-CNT interstices, polymer melts exert a capillarity-induced attractive force laterally on CNTs at the moving meniscus, leading to locally agglomerated macroscale bunches. Such a large configurational change can deform and distort individual CNTs so much as to cause buckling or breakdown of the alignment. In view of membrane manufacturing, this irreversible distortion of nanotubes is detrimental, as it could block the transport path of the membranes. The failure mechanism of the polymer melt infiltration is largely attributed to steric hindrance and an energy penalty of confined polymer chains. Euler beam theory and scaling analysis affirm that CNTs with low aspect ratio, thick walls and sparse distribution can maintain their vertical alignment. Our results can enrich a mechanistic understanding of the polymer melt infiltration process and offer guidelines to the facile large-scale manufacturing of the CNT-polymer filter membranes.
Role of Coordination and Chelation in Utilization of Nutritionally Essential Trace Elements.
BIOCHEMISTRY, *TRANSITION METALS), (*CHELATE COMPOUNDS, BIOCHEMISTRY), (*DIALYSIS, CHEMICAL ANALYSIS), NUTRITION , IRON, CHROMIUM, PHOSPHATES, AMINO ACIDS, HYDROXIDES, ALCOHOLS, PEPTIDES, MEMBRANES, LIQUID FILTERS
Ghugare, G S; Nair, A; Nimkande, V; Sarode, P; Rangari, P; Khairnar, K
2017-02-01
To develop a method for the isolation and enrichment of bacteriophages selectively against specific bacteria coupled with a membrane filtration technique. Rapid isolation and concentration of host-specific bacteriophages was achieved by exposure of the sample suspected to contain bacteriophages to a specific host immobilized on a 0·45 μm membrane in a membrane filtration unit. The principle behind this method is the exploitation of host-specific interaction of bacteriophages with their host and maximizing this interaction using a classic membrane filtration method. This provides a chance for each bacteriophage in the sample to interact with the specific host on the membrane filter fitted with a vacuum pump. Specific bacteriophages of the host are retained on the membrane along with its host cells due to the effect of adsorption and these adsorbed bacteriophages (along with their hosts) on the filter disc are then amplified and enriched in regular nutritive broth tryptose soya broth by incubation. With the help of the plaque assay method, host-specific phages of various bacterial species were isolated, segregated and enriched. The phage concentration method coupled with membrane filtration immobilization of host bacteria was able to isolate and enrich the host-specific bacteriophages by several fold using a lower quantity of an environmental water sample, or other phage suspensions. Enrichment of phages from single plaques was also achieved. The isolation and detection of host-specific bacteriophages from a low density bacteriophage water sample in a single step by the use of a simple and basic microbiological technique can be achieved. Enrichment of phages from low phage titre suspensions is also achieved very effectively. © 2016 The Society for Applied Microbiology.
The impact of chlorhexidine mouth rinse on the bond strength of polycarbonate orthodontic brackets.
Hussein, Farouk Ahmed; Hashem, Mohammed Ibrahim; Chalisserry, Elna P; Anil, Sukumaran
2014-11-01
The purpose of the current in-vivo study was to assess the effect of using 0.12% chlorhexidine (CHX) mouth rinse, before bonding, on shear bond strength of polycarbonate brackets bonded with composite adhesive. Eighteen orthodontic patients with a mean age 21.41 ± 1.2 years, who were scheduled to have 2 or more first premolars extracted, were included in this study. Patients were referred for an oral prophylaxis program which included, in part, the use of a mouth rinse. Patients were divided into 2 groups, a test group of 9 patients who used 0.12% CHX gluconate mouth rinse twice daily and a control group of 9 patients who used a mouth rinse without CHX, but with same color. After 1 week, polycarbonate brackets were bonded to first premolars with Transbond XT composite adhesive. Premolars were extracted after 28 days and tested for shear bond strength on a universal testing machine. Student's t-test was used to compare shear bond strengths of both groups. No statistically significant difference was found in bond strengths' values between both groups. The test group (with CHX) has mean shear bond strength of 14.21 ± 2.42 MPa whereas the control group (without CHX) revealed a mean strength of 14.52 ± 2.31 MPa. The use of 0.12% CHX mouth rinse, for one week before bonding, did not affect the shear bond strength of polycarbonate brackets bonded with Transbond composite. Furthermore, these brackets showed clinically acceptable bond strength.
Experimental comparison of point-of-use filters for drinking water ultrafiltration.
Totaro, M; Valentini, P; Casini, B; Miccoli, M; Costa, A L; Baggiani, A
2017-06-01
Waterborne pathogens such as Pseudomonas spp. and Legionella spp. may persist in hospital water networks despite chemical disinfection. Point-of-use filtration represents a physical control measure that can be applied in high-risk areas to contain the exposure to such pathogens. New technologies have enabled an extension of filters' lifetimes and have made available faucet hollow-fibre filters for water ultrafiltration. To compare point-of-use filters applied to cold water within their period of validity. Faucet hollow-fibre filters (filter A), shower hollow-fibre filters (filter B) and faucet membrane filters (filter C) were contaminated in two different sets of tests with standard bacterial strains (Pseudomonas aeruginosa DSM 939 and Brevundimonas diminuta ATCC 19146) and installed at points-of-use. Every day, from each faucet, 100 L of water was flushed. Before and after flushing, 250 mL of water was collected and analysed for microbiology. There was a high capacity of microbial retention from filter C; filter B released only low Brevundimonas spp. counts; filter A showed poor retention of both micro-organisms. Hollow-fibre filters did not show good micro-organism retention. All point-of-use filters require an appropriate maintenance of structural parameters to ensure their efficiency. Copyright © 2016 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.
Flachsbart, Bruce R; Wong, Kachuen; Iannacone, Jamie M; Abante, Edward N; Vlach, Robert L; Rauchfuss, Peter A; Bohn, Paul W; Sweedler, Jonathan V; Shannon, Mark A
2006-05-01
The design and fabrication of a multilayered polymer micro-nanofluidic chip is described that consists of poly(methylmethacrylate) (PMMA) layers that contain microfluidic channels separated in the vertical direction by polycarbonate (PC) membranes that incorporate an array of nanometre diameter cylindrical pores. The materials are optically transparent to allow inspection of the fluids within the channels in the near UV and visible spectrum. The design architecture enables nanofluidic interconnections to be placed in the vertical direction between microfluidic channels. Such an architecture allows microchannel separations within the chip, as well as allowing unique operations that utilize nanocapillary interconnects: the separation of analytes based on molecular size, channel isolation, enhanced mixing, and sample concentration. Device fabrication is made possible by a transfer process of labile membranes and the development of a contact printing method for a thermally curable epoxy based adhesive. This adhesive is shown to have bond strengths that prevent leakage and delamination and channel rupture tests exceed 6 atm (0.6 MPa) under applied pressure. Channels 100 microm in width and 20 microm in depth are contact printed without the adhesive entering the microchannel. The chip is characterized in terms of resistivity measurements along the microfluidic channels, electroosmotic flow (EOF) measurements at different pH values and laser-induced-fluorescence (LIF) detection of green-fluorescent protein (GFP) plugs injected across the nanocapillary membrane and into a microfluidic channel. The results indicate that the mixed polymer micro-nanofluidic multilayer chip has electrical characteristics needed for use in microanalytical systems.
Gabbanini, Simone; Matera, Riccardo; Beltramini, Claudia; Minghetti, Andrea; Valgimigli, Luca
2010-08-01
A convenient method for in vitro investigation of the release of lipid- and water-soluble vitamins from cosmetic formulations was developed. The permeation of (d)-alpha-tocopherol (vitamin E), retinyl acetate (pro-vitamin A), ascorbic acid (vitamin C) and pyridoxine (vitamin B6) through SkinEthic reconstructed human epidermis (RHE), and synthetic polyethersulfone and polycarbonate membranes was studied in vitro using a Franz-type diffusion apparatus, coupled either to a spectrophotometer for continuous reading (dynamic setting) or to HPLC-DAD analysis of the receptor medium (static setting). O/W and W/O emulsions were compared with simple aqueous solutions for their kinetic of vitamins release, to evaluate the influence of the cosmetic formulation on the bioavailability of active ingredients. Results indicate that synthetic membranes offer a limited barrier to the diffusion of vitamins, but may provide information on the release ability of the formulation. Penetration was more effective when water was the external phase of the formulation, i.e. W/O emulsions were less effective in the release of vitamins than O/W emulsion or aqueous solutions. RHE (17 days old) offered a significantly higher barrier to penetration of vitamins, as expected for native human epidermis. The relative ranking in coefficient of permeability (Ps (cm/h)) was: ascorbic acid>pyridoxine>retinyl acetate>alpha-tocopherol approximately 0, the absolute values depending on the formulation. The method herein described showed to be a practical and convenient tool for the quality-control and efficacy evaluation of cosmetic formulations. Copyright (c) 2010 Elsevier B.V. All rights reserved.
Zhang, Minglu; Jiang, Sunny; Tanuwidjaja, Dian; Voutchkov, Nikolay; Hoek, Eric M. V.; Cai, Baoli
2011-01-01
Seawater reverse osmosis (SWRO) membrane biofouling remains a common challenge in the desalination industry, but the marine bacterial community that causes membrane fouling is poorly understood. Microbial communities at different stages of treatment processes (intake, cartridge filtration, and SWRO) of a desalination pilot plant were examined by both culture-based and culture-independent approaches. Bacterial isolates were identified to match the genera Shewanella, Alteromonas, Vibrio, and Cellulophaga based on 16S rRNA gene sequencing analysis. The 16S rRNA gene clone library of the SWRO membrane biofilm showed that a filamentous bacterium, Leucothrix mucor, which belongs to the gammaproteobacteria, accounted for nearly 30% of the clone library, while the rest of the microorganisms (61.2% of the total clones) were related to the alphaproteobacteria. 16S rRNA gene terminal restriction fragment length polymorphism (T-RFLP) analysis indicated that bacteria colonizing the SWRO membrane represented a subportion of microbes in the source seawater; however, they were quite different from those colonizing the cartridge filter. The examination of five SWRO membranes from desalination plants located in different parts of the world showed that although the bacterial communities from the membranes were not identical to each other, some dominant bacteria were commonly observed. In contrast, bacterial communities in source seawater were significantly different based on location and season. Microbial profiles from 14 cartridge filters collected from different plants also revealed spatial trends. PMID:21551282
Pulawski, Wojciech; Jamroz, Michal; Kolinski, Michal; Kolinski, Andrzej; Kmiecik, Sebastian
2016-11-28
The CABS coarse-grained model is a well-established tool for modeling globular proteins (predicting their structure, dynamics, and interactions). Here we introduce an extension of the CABS representation and force field (CABS-membrane) to the modeling of the effect of the biological membrane environment on the structure of membrane proteins. We validate the CABS-membrane model in folding simulations of 10 short helical membrane proteins not using any knowledge about their structure. The simulations start from random protein conformations placed outside the membrane environment and allow for full flexibility of the modeled proteins during their spontaneous insertion into the membrane. In the resulting trajectories, we have found models close to the experimental membrane structures. We also attempted to select the correctly folded models using simple filtering followed by structural clustering combined with reconstruction to the all-atom representation and all-atom scoring. The CABS-membrane model is a promising approach for further development toward modeling of large protein-membrane systems.
Testing of Synthetic Biological Membranes for Forward Osmosis Applications
NASA Technical Reports Server (NTRS)
Parodi, Jurek; Mangado, Jaione Romero; Stefanson, Ofir; Flynn, Michael; Mancinelli, Rocco; Kawashima, Brian; Trieu, Serena; Brozell, Adrian; Rosenberg, Kevan
2016-01-01
Commercially available forward osmosis membranes have been extensively tested for human space flight wastewater treatment. Despite the improvements achieved in the last decades, there is still a challenge to produce reliable membranes with anti-fouling properties, chemical resistance, and high flux and selectivity. Synthetic biological membranes that mimic the ones present in nature, which underwent millions of years of evolution, represent a potential solution for further development and progress in membrane technology. Biomimetic forward osmosis membranes based on a polymeric support filter and coated with surfactant multilayers have been engineered to investigate how different manufacturing processes impact the performance and structure of the membrane. However, initial results of the first generation prototype membranes tests reveal a high scatter in the data, due to the current testing apparatus set up. The testing apparatus has been upgraded to improve data collection, reduce errors, and to allow higher control of the testing process.
Zuriaga-Agustí, E; Mendoza-Roca, J A; Bes-Piá, A; Alonso-Molina, J L; Fernández-Giménez, E; Álvarez-Requena, C; Muñagorri-Mañueco, F; Ortiz-Villalobos, G
2016-09-01
In the last years, biological treatment plants for the previously separated organic fraction from municipal solid wastes (OFMSW) have gained importance. In these processes a liquid effluent (liquid fraction from the digestate and leachate from composting piles), which has to be treated previously to its discharge, is produced. In this paper, the characteristics of the mixed liquor from two full-scale membrane bioreactors treating the effluents of two OFMSW treatment plants have been evaluated in view to study their influence on membrane fouling in terms of filterability. For that, the mixed liquor samples have been ultrafiltrated in an UF laboratory plant. Besides, the effect of the influent characteristics to MBRs and the values of the chemical and physical parameters of the mixed liquors on the filterability have been studied. Results showed that the filterability of the mixed liquor was strongly influenced by the soluble microbial products in the mixed liquors and the influent characteristics to MBR. Permeate flux of MBR mixed liquor treating the most polluted wastewater was considerable the lowest (around 20 L/m(2) h for some samples), what was explained by viscosity and soluble microbial products concentration higher than those measured in other MBR mixed liquor. Copyright © 2016 Elsevier Ltd. All rights reserved.
The presence-absence coliform test for monitoring drinking water quality.
Rice, E W; Geldreich, E E; Read, E J
1989-01-01
The concern for improved monitoring of the sanitary quality of drinking water has prompted interest in alternative methods for the detection of total coliform bacteria. A simplified qualitative presence-absence test has been proposed as an alternate procedure for detecting coliform bacteria in potable water. In this paper data from four comparative studies were analyzed to compare the recovery of total coliform bacteria from drinking water using the presence-absence test, the multiple fermentation tube procedure, and the membrane filter technique. The four studies were of water samples taken from four different geographic areas of the United States: Hawaii, New England (Vermont and New Hampshire), Oregon, and Pennsylvania. Analysis of the results of these studies were compared, based upon the number of positive samples detected by each method. Combined recoveries showed the presence-absence test detected significantly higher numbers of samples with coliforms than either the fermentation tube or membrane filter methods, P less than 0.01. The fermentation tube procedure detected significantly more positive samples than the membrane filter technique, P less than 0.01. Based upon the analysis of the combined data base, it is clear that the presence-absence test is as sensitive as the current coliform methods for the examination of potable water. The presence-absence test offers a viable alternative to water utility companies that elect to use the frequency-of-occurrence approach for compliance monitoring. PMID:2493663
Yamamura, Hiroshi; Kimura, Katsuki; Higuchi, Kumiko; Watanabe, Yoshimasa; Ding, Qing; Hafuka, Akira
2015-12-15
While low-pressure membrane filtration processes (i.e., microfiltration and ultrafiltration) can offer precise filtration than sand filtration, they pose the problem of reduced efficiency due to membrane fouling. Although many studies have examined membrane fouling by organic substances, there is still not enough data available concerning membrane fouling by inorganic substances. The present research investigated changes in the amounts of inorganic components deposited on the surface of membrane filters over time using membrane specimens sampled thirteen times at arbitrary time intervals during pilot testing in order to determine the mechanism by which irreversible fouling by inorganic substances progresses. The experiments showed that the inorganic components that primarily contribute to irreversible fouling vary as filtration continues. It was discovered that, in the initial stage of operation, the main membrane-fouling substance was iron, whereas the primary membrane-fouling substances when operation finished were manganese, calcium, and silica. The amount of iron accumulated on the membrane increased up to the thirtieth day of operation, after which it reached a steady state. After the accumulation of iron became static, subsequent accumulation of manganese was observed. The fact that the removal rates of these inorganic components also increased gradually shows that the size of the exclusion pores of the membrane filter narrows as operation continues. Studying particle size distributions of inorganic components contained in source water revealed that while many iron particles are approximately the same size as membrane pores, the fraction of manganese particles slightly smaller than the pores in diameter was large. From these results, it is surmised that iron particles approximately the same size as the pores block them soon after the start of operation, and as the membrane pores narrow with the development of fouling, they become further blocked by manganese particles approximately the same size as the narrowed pores. Calcium and silica are assumed to accumulate on the membrane due to their cross-linking action and/or complex formation with organic substances such as humic compounds. The present research is the first to clearly show that the inorganic components that contribute to membrane fouling differ according to the stage of membrane fouling progression; the information obtained by this research should enable chemical cleaning or operational control in accordance with the stage of membrane fouling progression. Copyright © 2015 Elsevier Ltd. All rights reserved.
Niki, Yoko; Yoshida, Masaki; Ito, Masaaki; Akiyama, Kaoru; Kim, Jin-Hwa; Yoon, Tae-Jin; Matsui, Mary S; Yarosh, Daniel B; Ichihashi, Masamitsu
2011-01-01
The mechanism of melanosome transfer from melanocytes to keratinocytes has not been fully clarified. We now show a route of melanosome transfer using co-cultures of normal human melanocytes and keratinocytes. Substantial levels of melanosome transfer were elicited in co-cultures of melanocytes and keratinocytes separated by a microporous membrane filter. The melanocyte dendrites penetrated into the keratinocyte layer through the filter and many pigment globules were observed in keratinocytes. Electron microscopic observations revealed that melanosomes incorporated in keratinocytes were packed in clusters enclosed by a double membrane. Numerous pigment globules budded off from melanocyte dendrites and were released into the culture medium. Those pigment globules were filled with multiple melanosomes and a few mitochondria but no nuclei. When those globules were added to the culture medium of keratinocytes, they were incorporated and showed double membrane-enclosed melano-phagolysosomes consistent with the structures obtained from the co-culture system. In contrast, when individual naked melanosomes isolated from melanocytes were added to keratinocytes, they were also phagocytosed by keratinocytes but were enclosed by a single membrane in a manner distinct from the co-culture system. These results suggest a novel mechanism of melanosome transfer, wherein melanosomes are packed in membrane globules that bud off from melanocyte dendrites, where they are released into the extracellular space and then phagocytosed by keratinocytes. PMID:21686100
Multiscale modeling of a Chemofilter device for filtering chemotherapy toxins from blood
NASA Astrophysics Data System (ADS)
Maani, Nazanin; Beyhaghi, Saman; Yee, Daryl; Nosonovsky, Micheal; Greer, Julia; Hetts, Steven; Rayz, Vitaliy
2016-11-01
Purpose: Chemotherapy drugs injected intra-arterially to treat cancer can cause systemic toxic effects. A catheter-based Chemofilter device, temporarily deployed in a vein during the procedure can filter excessive drug from the blood thus reducing chemotherapy side-effects. CFD modeling is used to design the membrane of the Chemofilter in order to optimize its hemodynamic performance. Methods: Multiscale approach is used to model blood flow through the Chemofilter. The toxins bind to the Chemofilter's membrane formed by a lattice of numerous micro cells deployed in a blood vessel of much larger size. A detailed model of the flow through a 2x2 microcell matrix with periodic boundary conditions is used to determine the permeability of the membrane. The results are used to simulate the flow through the whole device modeled as a uniform porous membrane. The finite-volume solver Fluent is used to obtain the numerical solution. Results: The micro cell matrix has a porosity of 0.92. The pressure drop across the resolved microcells was found to be 630 Pa, resulting in the permeability of 6.21 x10-11 m2 in the normal direction. These values were used to optimize the device geometry in order to increase the contact area of the membrane, while minimizing its obstruction to the flow. NIH NCI R01CA194533.
Influence of operational conditions on the performance of a mesh filter activated sludge process.
Fuchs, W; Resch, C; Kernstock, M; Mayer, M; Schoeberl, P; Braun, R
2005-03-01
Recently, a new type of wastewater treatment system became the focus of scientific research, the mesh filter activated sludge system. It is a modification of the membrane bioreactor where a membrane filtration process serves to separate the sludge from the purified effluent. The difference is that a mesh filter is used instead of the membrane. Due to the much larger pore size of the mesh, the effluent is not of the same excellent quality as with membrane bioreactors. Nevertheless, it still resembles the quality of the now most widely used standard treatment system, where settling tanks are used to retain the activated sludge. At the same time, the new system features all the other advantages of membrane bioreactors including elevated sludge concentrations resulting in decreased volumina of basins and complete substitution of the settling tank. Therefore, this process presents a potential future alternative where a small footprint of the plant is required. However, so far only a few preliminary studies on this innovative process type have been done. In this paper, the effects of suspended solids concentration, flux rate as well as aeration rate on the effluent quality are discussed. Furthermore, the characteristic of the sludge floc was identified as a factor of vital importance. Therefore, another influencing parameter, the food to microorganism (F/M) ratio, which is known to have a significant effect on floc characteristics, was studied. The main result demonstrated that the process was very effective under most of the operation conditions. The suspended solids concentration in the effluent was below 12 mg l(-1), the average COD in the effluent was between 24 and 45 mg l(-1) and the BOD(5) was lower than 5 mg l(-1). High flux rates of up to 150 l m(-2)h(-1) were also achieved.
NASA Astrophysics Data System (ADS)
Choong, Gabriel Y. H.; De Focatiis, Davide S. A.
2015-05-01
In this work we investigate the effects of compounding temperature and secondary melt processing on the mechanical response and electrical behaviour of polycarbonate filled with 3 wt% carbon nanotubes. The nanocomposites were melt compounded in an industrial setting at a range of temperatures, and subsequently injection moulded or compression moulded. The surface hardness, uniaxial tensile properties and electrical resistivity were measured. Secondary melt processing is found to be the dominant process in determining the final mechanical properties and resistivity of these materials.
Chemical Degradation and Stress Cracking of Polycarbonate in DS2.
1987-09-01
materials are used. For instance, polycarbonate, used widely for air- craft windows, helicopter canopies and transparent armor because of its good impact ...predicting environmental stress cracking of the polymer from solubility con- siderations. The concept has been extended to include a hydrogen bonding...IML Authors . 04 * ! 9 00 9 A S . - . . . q w * . - .* *,.*A CC AX -4-’-~~~~ U--’- ; IO i- A - -C4 = tO -~’ 1 .’ . M0 C , W V E WE1 C ~ 0.0.’un WEC
Study on the behavior and mechanism of polycarbonate with hot-water aging
NASA Astrophysics Data System (ADS)
Kong, L. P.; Zhao, Y. X.; Zhou, C. H.; Huang, Y. H.; Tang, M.; Gao, J. G.
2016-07-01
The present work was concerned with hot-water aging behavior and mechanism of Bisphenol A polycarbonate (PC) used as food and packaging materials. It indicated that with the aging time prolonged, PC sample had internal defects and the mechanical properties of PC materials changed not too much, molecular weight decreased, thermal stability declined. Phenolic hydroxyl absorption intensity enhanced in IR spectra and the maximum absorption wavelength red shift of benzene in UV-Vis spectra, the level of BPA increased. The color change of PC sample was not apparent.
Enrichment of heavy nuclei in the 17 April 1972 solar flare.
NASA Technical Reports Server (NTRS)
Fleischer, R. L.; Hart, H. R., Jr.
1973-01-01
Polycarbonate and glass detectors exposed on Apollo 16 to the Apr. 17, 1972, solar flare were used to measure the spectrum of iron-group cosmic-ray nuclei down to about 0.02 MeV/nucleon. The enrichment of iron relative to lighter nuclei previously seen at higher energies increases markedly in this new, very-low-energy region. The energy spectrum of carbon and heavier nuclei inferred from sensitized Lexan polycarbonate reveals the enrichment of iron relative to carbon and heavier nuclei down to about 0.03 MeV/nucleon.
X-ray diffraction diagnostic design for the National Ignition Facility
NASA Astrophysics Data System (ADS)
Ahmed, Maryum F.; House, Allen; Smith, R. F.; Ayers, Jay; Lamb, Zachary S.; Swift, David W.
2013-09-01
This paper describes the design considerations for Target Diffraction In-Situ (TARDIS), an x-ray diffraction diagnostic at the National Ignition Facility. A crystal sample is ramp-compressed to peak pressures between 10 and 30 Mbar and, during a pressure hold period, is probed with quasi-monochromatic x-rays emanating from a backlighter source foil. The crystal spectrography diffraction lines are recorded onto image plates. The crystal sample, filter, and image plates are packaged into one assembly, allowing for accurate and repeatable target to image plate registration. Unconverted laser light impinges upon the device, generating debris, the effects of which have been mitigated. Dimpled blast shields, high strength steel alloy, and high-z tungsten are used to shield and protect the image plates. A tapered opening was designed to provide adequate thickness of shielding materials without blocking the drive beams or x-ray source from reaching the crystal target. The high strength steel unit serves as a mount for the crystal target and x-ray source foil. A tungsten body contains the imaging components. Inside this sub-assembly, there are three image plates: a 160 degree field of view curved plate directly opposite the target opening and two flat plates for the top and bottom. A polycarbonate frame, coated with the appropriate filter material and embedded with registration features for image plate location, is inserted into the diagnostic body. The target assembly is metrologized and then the diagnostic assembly is attached.
Interferometric tomography of fuel cells for monitoring membrane water content.
Waller, Laura; Kim, Jungik; Shao-Horn, Yang; Barbastathis, George
2009-08-17
We have developed a system that uses two 1D interferometric phase projections for reconstruction of 2D water content changes over time in situ in a proton exchange membrane (PEM) fuel cell system. By modifying the filtered backprojection tomographic algorithm, we are able to incorporate a priori information about the object distribution into a fast reconstruction algorithm which is suitable for real-time monitoring.
Zheng, Wei-Chao; Xie, Rui; He, Li-Qun; Xi, Yue-Heng; Liu, Ying-Mei; Meng, Zhi-Jun; Wang, Wei; Ju, Xiao-Jie; Chen, Gang; Chu, Liang-Yin
2015-01-01
A novel microfluidic device for highly efficient and robust dialysis without membrane is highly desired for the development of portable or wearable microdialyzer. Here we report an enhanced H-filter with pillar array based on Fåhræus-Lindqvist effect (F-L effect) for highly efficient and robust membraneless dialysis of simplified blood for the first time. The H-filter employs two fluids laminarly flowing in the microchannel for continuously membraneless dialysis. With pillar array in the microchannel, the two laminar flows, with one containing blood cells and small molecules and another containing dialyzate solution, can form a cell-free layer at the interface as selective zones for separation. This provides enhanced mixing yet extremely low shear for extraction of small molecules from the blood-cell-containing flow into the dialyzate flow, resulting in robust separation with reduced cell loss and improved efficiency. We demonstrate this by first using Chlorella pyrenoidosa as model cells to quantitatively study the separation performances, and then using simplified human blood for dialysis. The advanced H-filter, with highly efficient and robust performance for membraneless dialysis, shows great potential as promising candidate for rapid blood analysis/separation, and as fundamental structure for portable dialyzer. PMID:26339313
Zheng, Wei-Chao; Xie, Rui; He, Li-Qun; Xi, Yue-Heng; Liu, Ying-Mei; Meng, Zhi-Jun; Wang, Wei; Ju, Xiao-Jie; Chen, Gang; Chu, Liang-Yin
2015-07-01
A novel microfluidic device for highly efficient and robust dialysis without membrane is highly desired for the development of portable or wearable microdialyzer. Here we report an enhanced H-filter with pillar array based on Fåhræus-Lindqvist effect (F-L effect) for highly efficient and robust membraneless dialysis of simplified blood for the first time. The H-filter employs two fluids laminarly flowing in the microchannel for continuously membraneless dialysis. With pillar array in the microchannel, the two laminar flows, with one containing blood cells and small molecules and another containing dialyzate solution, can form a cell-free layer at the interface as selective zones for separation. This provides enhanced mixing yet extremely low shear for extraction of small molecules from the blood-cell-containing flow into the dialyzate flow, resulting in robust separation with reduced cell loss and improved efficiency. We demonstrate this by first using Chlorella pyrenoidosa as model cells to quantitatively study the separation performances, and then using simplified human blood for dialysis. The advanced H-filter, with highly efficient and robust performance for membraneless dialysis, shows great potential as promising candidate for rapid blood analysis/separation, and as fundamental structure for portable dialyzer.
Silica incorporated membrane for wastewater based filtration
NASA Astrophysics Data System (ADS)
Fernandes, C. S.; Bilad, M. R.; Nordin, N. A. H. M.
2017-10-01
Membrane technology has long been applied for waste water treatment industries due to its numerous advantages compared to other conventional processes. However, the biggest challenge in pressure driven membrane process is membrane fouling. Fouling decreases the productivity and efficiency of the filtration, reduces the lifespan of the membrane and reduces the overall efficiency of water treatment processes. In this study, a novel membrane material is developed for water filtration. The developed membrane incorporates silica nanoparticles mainly to improve its structural properties. Membranes with different loadings of silica nanoparticles were applied in this study. The result shows an increase in clean water permeability and filterability of the membrane for treating activated sludge, microalgae solution, secondary effluent and raw sewage as feed. Adding silica into the membrane matrix does not significantly alter contact angle and membrane pore size. We believe that silica acts as an effective pore forming agent that increases the number of pores without significantly altering the pore sizes. A higher number of small pores on the surface of the membrane could reduce membrane fouling because of a low specific loading imposed to individual pores.
Antibacterial performance of nano polypropylene filter media containing nano-TiO2 and clay particles
NASA Astrophysics Data System (ADS)
Shafiee, Sara; Zarrebini, Mohammad; Naghashzargar, Elham; Semnani, Dariush
2015-10-01
Disinfection and elimination of pathogenic microorganisms from liquid can be achieved by filtration process using antibacterial filter media. The advent of nanotechnology has facilitated the introduction of membranes consisting of nano-fiber in filtration operations. The melt electro-spun fibers due to their extremely small diameters are used in the production of this particular filtration medium. In this work, antibacterial polypropylene filter medium containing clay particles and nano-TiO2 were made using melt electro-spun technology. Antibacterial performance of polypropylene nano-filters was evaluated using E. coli bacteria. Additionally, filtration efficiency of the samples in terms fiber diameter, filter porosity, and fiber distribution using image processing technique was determined. Air permeability and dust aerosol tests were conducted to establish the suitability of the samples as a filter medium. It was concluded that as far as antibacterial property is concerned, nano-fibers filter media containing clay particles are preferential to similar media containing TiO2 nanoparticles.
Multinuclear NMR studies of single lipid bilayers supported in cylindrical aluminum oxide nanopores.
Gaede, Holly C; Luckett, Keith M; Polozov, Ivan V; Gawrisch, Klaus
2004-08-31
Lipid bilayers were deposited inside the 0.2 microm pores of anodic aluminum oxide (AAO) filters by extrusion of multilamellar liposomes and their properties studied by 2H, 31P, and 1H solid-state NMR. Only the first bilayer adhered strongly to the inner surface of the pores. Additional layers were washed out easily by a flow of water as demonstrated by 1H magic angle spinning NMR experiments with addition of Pr3+ ions to shift accessible lipid headgroup resonances. A 13 mm diameter Anopore filter of 60 microm thickness oriented approximately 2.5 x 10(-7) mol of lipid as a single bilayer, corresponding to a total membrane area of about 500 cm2. The 2H NMR spectra of chain deuterated POPC are consistent with adsorption of wavy, tubular bilayers to the inner pore surface. By NMR diffusion experiments, we determined the average length of those lipid tubules to be approximately 0.4 microm. There is evidence for a thick water layer between lipid tubules and the pore surface. The ends of tubules are well sealed against the pore such that Pr3+ ions cannot penetrate into the water underneath the bilayers. We successfully trapped poly(ethylene glycol) (PEG) with a molecular weight of 8000 in this water layer. From the quantity of trapped PEG, we calculated an average water layer thickness of 3 nm. Lipid order parameters and motional properties are unperturbed by the solid support, in agreement with existence of a water layer. Such unperturbed, solid supported membranes are ideal for incorporation of membrane-spanning proteins with large intra- and extracellular domains. The experiments suggest the promise of such porous filters as membrane support in biosensors.
The Pressure-Dependence of the Size of Extruded Vesicles
Patty, Philipus J.; Frisken, Barbara J.
2003-01-01
Variations in the size of vesicles formed by extrusion through small pores are discussed in terms of a simple model. Our model predicts that the radius should decrease as the square root of the applied pressure, consistent with data for vesicles extruded under various conditions. The model also predicts dependencies on the pore size used and on the lysis tension of the vesicles being extruded that are consistent with our data. The pore size was varied by using track-etched polycarbonate membranes with average pore diameters ranging from 50 to 200 nm. To vary the lysis tension, vesicles made from POPC (1-palmitoyl-2-oleoyl-sn-glycero-3-phosphatidylcholine), mixtures of POPC and cholesterol, and mixtures of POPC and C16-ceramide were studied. The lysis tension, as measured by an extrusion-based technique, of POPC:cholesterol vesicles is higher than that of pure POPC vesicles whereas POPC:ceramide vesicles have lower lysis tensions than POPC vesicles. PMID:12885646
Protein immobilization onto electrochemically synthesized CoFe nanowires
Torati, Sri Ramulu; Reddy, Venu; Yoon, Seok Soo; Kim, CheolGi
2015-01-01
CoFe nanowires have been synthesized by the electrodeposition technique into the pores of a polycarbonate membrane with a nominal pore diameter of 50 nm, and the composition of CoFe nanowires varying by changing the source concentration of iron. The synthesized nanowire surfaces were functionalized with amine groups by treatment with aminopropyltriethoxysilane (APTES) linker, and then conjugated with streptavidin-Cy3 protein via ethyl (dimethylaminopropyl) carbodiimide and N-hydroxysuccinimide coupling chemistry. The oxide surface of CoFe nanowire is easily modified with aminopropyltriethoxysilane to form an amine terminating group, which is covalently bonded to streptavidin-Cy3 protein. The physicochemical properties of the nanowires were analyzed through different characterization techniques such as scanning electron microscope, energy dispersive spectroscopy, and vibrating sample magnetometer. Fluorescence microscopic studies and Fourier transform infrared studies confirmed the immobilization of protein on the nanowire surface. In addition, the transmission electron microscope analysis reveals the thin protein layer which is around 12–15 nm on the nanowire surfaces. PMID:25609966
Fletcher, Heidi J.; Stenken, Julie A.
2008-01-01
Cyclodextrins and antibodies have been used as affinity agents to improve relative recovery during microdialysis sampling. Two neuropeptides, methionine-enkephalin (ME) and leucine-enkephalin (LE), were chosen to compare the use of cyclodextrins and antibodies as possible affinity agents for improving their relative recovery across polycarbonate and polyethersulfone membranes during in vitro sampling. Cyclodextrins (CD) including β-CD, 2-hydroxypropyl-β-cyclodextrin (2HPβ-CD), and γ-CD gave improvements of relative recovery for both peptides of less than 2-fold as compared to controls. Comparisons of relative recovery between tyrosine-glycine-glycine, tyrosine, and phenylalanine using different cyclodextrins in the perfusion fluid were also obtained. Inclusion of an antibody against met-enkephalin in the microdialysis perfusion fluid resulted in relative recovery increases of up to 2.5-fold. These results show that using antibodies as affinity agents during microdialysis sampling may be more effective agents to improve the relative recovery of these opioid neuropeptides. PMID:18558138
Cecil, L.D.; Knobel, L.L.; Wegner, S.J.; Moore, L.L.
1989-01-01
Water from four wells completed in the Snake River Plain aquifer was sampled as part of the U.S. Geological Survey 's quality assurance program to evaluate the effect of filtration and preservation methods on strontium-90 concentrations in groundwater at the Idaho National Engineering Laboratory. Water from each well was filtered through either a 0.45-micrometer membrane or a 0.1-micrometer membrane filter; unfiltered samples also were collected. Two sets of filtered and two sets of unfiltered samples was preserved in the field with reagent-grade hydrochloric acid and the other set of samples was not acidified. For water from wells with strontium-90 concentrations at or above the reporting level, 94% or more of the strontium-90 is in true solution or in colloidal particles smaller than 0.1 micrometer. These results suggest that within-laboratory reproducibility for strontium-90 in groundwater at the INEL is not significantly affected by changes in filtration and preservation methods used for sample collections. (USGS)
NASA Astrophysics Data System (ADS)
Entezarian, Majid; Geiger, Bob
2016-03-01
The trend in microelectronics fabrication is to produce nano-features measuring down to 10 nm and finer. The PPT levels of organic and inorganic contaminants in the photoresist, solvent and cleaning solutions are becoming a major processing variable affecting the process capability and defectivity. The photoresist usually contains gels, metals, and particulates that could interfere with the lithography process and cause microbridging defects. Nano filters of 5 nm polypropylene, 5 nm polyethylene, and 10 nm natural nylon were used to filter propylene glycol methyl ether acetate PGMEA containing 50 ppb of Na, Mg, Al, Ca, Cr, Mn, Fe, Cu, Zn, and Pb. All filters were effective in removing trivalent Al, Cr, and Fe metals indicating the mechanism for their removal as mechanical sieving. However, the nylon was also very effective in removing the divalent metals showing adsorptive properties. Furthermore, the metal removal of the nylon membrane was studied as a function of surface chemistry. Natural and charged 40 nm nylon membranes were tested and found that charged nylon is more effective for metal removal.
Evaluation of USEPA method 1622 for detection of Cryptosporidium oocysts in stream waters
Simmons, O. D.; Sobsey, M.D.; Schaefer, F. W.; Francy, D.S.; Nally, R.A.; Heaney, C.D.
2001-01-01
To improve surveillance for Cryptosporidium oocysts in water, the US Environmental Protection Agency developed method 1622, which consists of filtration, concentration, immunomagnetic separation, fluorescent antibody and 4, 6-diamidino-2-phenylindole (DAPI) counter-staining, and microscopic evaluation. Two filters were compared for analysis of 11 stream water samples collected throughout the United States. Replicate 10-L stream water samples (unspiked and spiked with 100-250 oocysts) were tested to evaluate matrix effects. Oocyst recoveries from the stream water samples averaged 22% (standard deviation [SD] = ??17%) with a membrane disk and 12% (SD = ??6%) with a capsule filter. Oocyst recoveries from reagent water precision and recovery samples averaged 39% (SD = ??13%) with a membrane disk and 47% (SD = ??19%) with a capsule filter. These results demonstrate that Cryptosporidium oocysts can be recovered from stream waters using method 1622, but recoveries are lower than those from reagent-grade water. This research also evaluated concentrations of indicator bacteria in the stream water samples. Because few samples were oocyst-positive, relationships between detections of oocysts and concentrations of indicator organisms could not be determined.
Hirayama, Yo; Oda, Shigeto; Wakabayashi, Kiyohito; Sadahiro, Tomohito; Nakamura, Masataka; Watanabe, Eizo; Tateishi, Yoshihisa
2011-01-01
We sought to identify the most relevant hemofilter for cytokine removal based on the mechanisms of filtration and adsorption. Ascites were filtered using four types of hemofilters composed of different membrane materials (polymethyl methacrylate, PMMA, cellulose triacetate, CTA, or polysulfone, PS) and different surface areas (1.0 or 2.1 m(2)) to investigate the rate of interleukin-6 (IL-6) filtration. Next, ascites were perfused through each hemofilter without obtaining a filtrate to study each filter's adsorptive capability. The PMMA hemofilters resulted in a marginal observed IL-6 filtration rates, whereas the CTA and PS hemofilters resulted in highly effective IL-6 filtration. Regarding the IL-6 adsorptive capabilities of the filters, the PMMA hemofilter with a large surface area showed the highest level of IL-6 clearance. The present findings suggest that when cytokine removal based on filtration is desired, CTA or PS hemofilters should be selected. When IL-6 removal based on adsorption is desired, a PMMA hemofilter with a large surface area should be selected. Copyright © 2010 S. Karger AG, Basel.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cecil, L.D.; Knobel, L.L.; Wegner, S.J.
1989-01-01
Water from four wells completed in the Snake River Plain aquifer was sampled as part of the US Geological Survey's quality assurance program to evaluate the effect of filtration and preservation methods on strontium-90 concentrations in groundwater at the Idaho National Engineering Laboratory. Water from each well was filtered through either a 0.45-micrometer membrane or a 0.1-micrometer membrane filter; unfiltered samples also were collected. Two sets of filtered and two sets of unfiltered samples was preserved in the field with reagent-grade hydrochloric acid and the other set of samples was not acidified. For water from wells with strontium-90 concentrations atmore » or above the reporting level, 94% or more of the strontium-90 is in true solution or in colloidal particles smaller than 0.1 micrometer. These results suggest that within-laboratory reproducibility for strontium-90 in groundwater at the INEL is not significantly affected by changes in filtration and preservation methods used for sample collections. 13 refs., 2 figs., 6 tabs.« less
NASA Astrophysics Data System (ADS)
Jimenez, K.; Gaballah, A. E. H.; Ahmed, Nadeem; Zuppella, P.; Nicolosi, P.
2017-05-01
High brilliance sources in the EUV spectral range such as Synchrotron and Free Electron Lasers (FEL) are widely used in multiple scientific and technological applications thanks to their peculiar characteristics. One main technical problem of FEL is related to the rejection of high harmonics, seed laser, first stage photons, and diffuse light; in order to improve the quality of the beam delivered by these sources, a suitable optical system acting as band-pass filters is necessary. In this paper we discuss the optical and structure characterization of Nb/Zr and Zr/Nb self-stand transmittance filters, designed for 4.5 nm-20 nm wavelength ranges. In order to understand the properties of these bilayers filters, a campaign of measurements has been planned to be performed on Zr and Nb films on Si3N4 membrane windows and silicon substrates, deposited with e- beam deposition technique. Comparison of the results has been planned too. IMD transmittance and reflectance simulations, together with preliminary AFM and reflectance measurements will be shown in this work.
Cooper, James E; Kendig, Eric L; Belcher, Scott M
2011-10-01
Bisphenol A (BPA) is a ubiquitous high volume industrial chemical that is an estrogen and an environmental endocrine disrupting chemical. Bisphenol A is used extensively in the production of consumer goods, polycarbonate plastics, epoxy resins and coatings used to line metallic food and beverage cans. There is great concern regarding the possible harmful effects from exposures that result from BPA leaching into foods and beverages from packaging or storage containers. The objective of this study was to independently assess whether BPA contamination of water was occurring from different types of reusable drinking bottles marketed as alternatives to BPA-containing polycarbonate plastics. Using a sensitive and quantitative BPA-specific competitive enzyme-linked immunosorbent assay we evaluated whether BPA migrated into water stored in polycarbonate or copolyester plastic bottles, and different lined or unlined metallic reusable water bottles. At room temperature the concentration of BPA migrating from polycarbonate bottles ranged from 0.2 to 0.3 mg L⁻¹. Under identical conditions BPA migration from aluminium bottles lined with epoxy-based resins was variable depending on manufacturer ranging from 0.08 to 1.9 mg L⁻¹. Boiling water significantly increased migration of BPA from the epoxy lined bottles. No detectable BPA contamination was observed in water stored in bottles made from Tritan™ copolyester plastic, uncoated stainless steel, or aluminium lined with EcoCare™. The results from this study demonstrate that when used according to manufacturers' recommendations reusable water bottles constructed from "BPA-free" alternative materials are suitable for consumption of beverages free of BPA contamination. Copyright © 2011 Elsevier Ltd. All rights reserved.
Kubwabo, C; Kosarac, I; Stewart, B; Gauthier, B R; Lalonde, K; Lalonde, P J
2009-06-01
Human exposure to bisphenol A (BPA) has recently received special attention. It has been shown that exposure to BPA may occur through the consumption of beverages or foods that have been in contact with polycarbonate (PC) plastic containers or epoxy resins in food packaging. A BPA migration study was conducted using a variety of plastic containers, including polycarbonate baby bottles, non-PC baby bottles, baby bottle liners, and reusable PC drinking bottles. Water was used to simulate migration into aqueous and acidic foods; 10% ethanol solution to simulate migration to low- and high-alcoholic foods; and 50% ethanol solution to simulate migration to fatty foods. By combining solid-phase extraction, BPA derivatization and analysis by GC-EI/MS/MS, a very low detection limit at the ng l(-1) level was obtained. Migration of BPA at 40 degrees C ranged from 0.11 microg l(-1) in water incubated for 8 h to 2.39 microg l(-1) in 50% ethanol incubated for 240 h. Residual BPA leaching from PC bottles increased with temperature and incubation time. In comparison with the migration observed from PC bottles, non-PC baby bottles and baby bottle liners showed only trace levels of BPA. Tests for leachable lead and cadmium were also conducted on glass baby bottles since these represent a potential alternative to plastic bottles. No detectable lead or cadmium was found to leach from the glass. This study indicated that non-PC plastic baby bottles, baby bottle liners and glass baby bottles might be good alternatives for polycarbonate bottles.
Removing Pathogens Using Nano-Ceramic-Fiber Filters
NASA Technical Reports Server (NTRS)
Tepper, Frederick; Kaledin, Leonid
2005-01-01
A nano-aluminum-oxide fiber of only 2 nanometers in diameter was used to develop a ceramic-fiber filter. The fibers are electropositive and, when formulated into a filter material (NanoCeram(TradeMark)), would attract electro-negative particles such as bacteria and viruses. The ability to detect and then remove viruses as well as bacteria is of concern in space cabins since they may be carried onboard by space crews. Moreover, an improved filter was desired that would polish the effluent from condensed moisture and wastewater, producing potable drinking water. A laboratory- size filter was developed that was capable of removing greater than 99.9999 percent of bacteria and virus. Such a removal was achieved at flow rates hundreds of times greater than those through ultraporous membranes that remove particles by sieving. Because the pore size of the new filter was rather large as compared to ultraporous membranes, it was found to be more resistant to clogging. Additionally, a full-size cartridge is being developed that is capable of serving a full space crew. During this ongoing effort, research demonstrated that the filter media was a very efficient adsorbent for DNA (deoxyribonucleic acid), RNA (ribonucleic acid), and endotoxins. Since the adsorption is based on the charge of the macromolecules, there is also a potential for separating proteins and other particulates on the basis of their charge differences. The separation of specific proteins is a major new thrust of biotechnology. The principal application of NanoCeram filters is based on their ability to remove viruses from water. The removal of more than 99.9999 percent of viruses was achieved by a NanoCeram polishing filter added to the effluent of an existing filtration device. NanoCeram is commercially available in laboratory-size filter discs and in the form of a syringe filter. The unique characteristic of the filter can be demonstrated by its ability to remove particulate dyes such as Metanyl yellow. Its particle size is only 2 nanometers, about the size of a DNA molecule, yet the NanoCeram syringe filter is capable of retaining the dyes as the fluid is passed through the syringe, without much back-pressure. Endotoxins, which are contaminants that are part of the residue of destroyed bacteria, can cause toxic shock and are therefore of major concern in pharmaceutical products. The NanoCeram syringe filter is capable of removing greater than 99.96 percent of the endotoxins.
Study of Adsorption of Copper Species onto Multiwall Carbon Nanotubes
Functionalized CNTs have improved adsorptive capacities over pristine CNTs. These can be used for sensors, membranes, filters and matrix composite enhancements made possible because of their nano-size.
Discrimination of Nosiheptide Sources with Plasmonic Filters.
Wang, Delong; Ni, Haibin; Wang, Zhongqiang; Liu, Bing; Chen, Hongyuan; Gu, Zhongze; Zhao, Xiangwei
2017-04-19
Bacteria identification plays a vital role in the field of clinical diagnosis, food industry, and environmental monitoring, which is in great demand of point of care detection methods. In this paper, in order to discriminate the source of nosiheptide product, a plasmonic filter was fabricated to filtrate, capture and identify Streptomycete spores with Surface enhanced Raman Scattering (SERS). Since the plasmonic filter was derived from self-assembled photonic crystal coated with silver, the plasmonic "hot spots" on the filter surface was distributed evenly in a fare good density and the SERS enhancement factor was 7.49 × 10 7 . With this filter, a stain- and PCR-free detection was realized with only 5 μL sample solution and 5 min in a manner of "filtration and measure". Comparison to traditional Gram stain method and silver-plated nylon filter membrane, the plasmonic filter showed good sensitivity and efficiency in the discrimination of nosiheptide prepared with chemical and biological methods. It is anticipated that this simple SERS detection method with plasmonic filter has promising potentials in food safety, environmental, or clinical applications.
Compact discs as versatile cost-effective substrates for releasable nanopatterned aluminium films
NASA Astrophysics Data System (ADS)
Barrios, Carlos Angulo; Canalejas-Tejero, Víctor
2015-02-01
We demonstrate that standard polycarbonate compact disk surfaces can provide unique adhesion to Al films that is both strong enough to permit Al film nanopatterning and weak enough to allow easy nanopatterned Al film detachment using Scotch tape. Transferred Al nanohole arrays on Scotch tape exhibit excellent optical and plasmonic performance.We demonstrate that standard polycarbonate compact disk surfaces can provide unique adhesion to Al films that is both strong enough to permit Al film nanopatterning and weak enough to allow easy nanopatterned Al film detachment using Scotch tape. Transferred Al nanohole arrays on Scotch tape exhibit excellent optical and plasmonic performance. Electronic supplementary information (ESI) available: 1. Optical simulations (Fig. SI.1); 2. Optical coupling via an Al NHA on the Scotch tape (Fig. SI.2); 3. Electrostatics-based opto-mechanical cantilever (Fig. SI.3). Video 1. Transfer of the Al film nanostructured with a nanohole array from a polycarbonate CD surface onto a Scotch tape; Video 2. Opto-mechanical electrostatics-based sensor: electrical attraction. Video 3. Opto-mechanical electrostatics-based sensor: electrical repulsion. See DOI: 10.1039/c4nr06271j
Experimental study on dynamic mechanical behaviors of polycarbonate
NASA Astrophysics Data System (ADS)
Zhang, Wei; Gao, Yubo; Ye, Nan; Huang, Wei; Li, Dacheng
2017-01-01
Polycarbonate (PC) is a widely used engineering material in aerospace field, since it has excellent mechanical and optical property. In present study, both compressive and tensile tests of PC were conducted at high strain rates by using a split Hopkinson pressure bar. The high-speed camera and 2D Digital Image Correlation method (DIC) were used to analyze the dynamic deformation behavior of PC. Meanwhile, the plate impact experiment was carried out to measure the equation of state of PC in a single-stage gas gun, which consists of asymmetric impact technology, manganin gauges, PVDF, electromagnetic particle velocity gauges. The results indicate that the yield stress of PC increased with the strain rates in both dynamic compression and tension tests. The same phenomenon was similar to elasticity modulus at different strain rate. A constitutive model was used to describe the mechanical behaviors of PC accurately in different strain rates by contrast with the results of 2D-DIC. At last, The D-u Hugoniot curve of polycarbonate in high pressure was fitted by the least square method.
Takahashi, Yutaka; Hamanaka, Ippei; Shimizu, Hiroshi
2012-07-01
This study investigated the effect of thermal shock on the mechanical properties of injection-molded thermoplastic denture base resins. Four thermoplastic resins (two polyamides, one polyethylene terephthalate, one polycarbonate) and, as a control, a conventional heat-polymerized polymethyl methacrylate (PMMA), were tested. Specimens of each denture base material were fabricated according to ISO 1567 and were either thermocycled or not thermocycled (n = 10). The flexural strength at the proportional limit (FS-PL), the elastic modulus and the Charpy impact strength of the denture base materials were estimated. Thermocycling significantly decreased the FS-PL of one of the polyamides and the PMMA and it significantly increased the FS-PL of one of the polyamides. In addition, thermocycling significantly decreased the elastic modulus of one of the polyamides and significantly increased the elastic moduli of one of the polyamides, the polyethylene terephthalate, polycarbonate and PMMA. Thermocycling significantly decreased the impact strength of one of the polyamides and the polycarbonate. The mechanical properties of injection-molded thermoplastic denture base resins changed after themocycling.
NASA Astrophysics Data System (ADS)
Bao, Junjie; Shi, Gaojian; Tao, Can; Wang, Chao; Zhu, Chen; Cheng, Liang; Qian, Gang; Chen, Chunhua
2018-06-01
Four kinds of polycarbonate-based polyurethane with 8-14 wt% hard segments content are synthesized via reactions of polycarbonatediol, hexamethylene diisocyanate and diethylene glycol. The mechanical strength of the polyurethanes increase with the increase of hard segments content. Solid polymer electrolytes composed of the polycarbonate-based polyurethanes and LiTFSI exhibits fascinating characteristics for all-solid-state lithium batteries with a high ionic conductivity of 1.12 × 10-4 S cm-1 at 80 °C, an electrochemical stability window up to 4.5 V (vs. Li+/Li), excellent mechanical strength and superior interfacial stability against lithium metal. The all-solid-state batteries using LiFePO4 cathode can deliver high discharge capacities (161, 158, 134 and 93 mAh g-1 at varied rates of 0.2, 0.5, 1 and 2 C) at 80 °C and excellent cycling performance (with 91% capacity retention after 600 cycles at 1 C). All the results indicate that such a polyurethane-based solid polymer electrolyte can be a promising candidate for all-solid-state lithium batteries.
Fabrication of Transparent Protective Diamond-Like Carbon Films on Polymer
NASA Astrophysics Data System (ADS)
Baek, Sang-min; Shirafuji, Tatsuru; Saito, Nagahiro; Takai, Osamu
2011-08-01
Si doped hydrogenated amorphous carbon (Si-DLC) films as a candidate protection coating for polycarbonate (PC) were prepared using a pulse-biased inductively coupled plasma chemical vapor deposition (ICP-CVD) system with a gas mixture of acetylene (C2H2) and tetramethylsilane [Si(CH3)4]. The effects of Si incorporation on the structure and optical properties of the Si-DLC films were investigated. In addition, plasma pretreatments with O2, N2, and Ar gases were carried out to enhance the adhesion strength of Si-DLC films on polycarbonate. Structural characterization through Raman and X-ray photoelectron spectroscopy (XPS) analyses showed that the incorporation of Si atoms in DLC films leads to an increase in the optical band gap (Eopt) with the formation of sp3 C-Si bonds. O2 plasma pretreatment improved the strength of adhesion of the Si-DLC films to polycarbonate, while Ar and N2 plasma treatments did not. This can be explained by the formation of an activated dense interfacial layer by O2 plasma pretreatment.
Freeing Water from Viruses and Bacteria
NASA Technical Reports Server (NTRS)
2004-01-01
Four years ago, Argonide Corporation, a company focused on the research, production, and marketing of specialty nano materials, was seeking to develop applications for its NanoCeram[R] fibers. Only 2 nanometers in diameter, these nano aluminum oxide fibers possessed unusual bio-adhesive properties. When formulated into a filter material, the electropositive fibers attracted and retained electro-negative particles such as bacteria and viruses in water-based solutions. This technology caught the interest of NASA as a possible solution for improved water filtration in space cabins. NASA's Johnson Space Center awarded Sanford, Florida-based Argonide a Phase I Small Business Innovation Research (SBIR) contract to determine the feasibility of using the company's filter for purifying recycled space cabin water. Since viruses and bacteria can be carried aboard space cabins by space crews, the ability to detect and remove these harmful substances is a concern for NASA. The Space Agency also desired an improved filter to polish the effluent from condensed and waste water, producing potable drinking water. During its Phase I partnership with NASA, Argonide developed a laboratory-size filter capable of removing greater than 99.9999 percent of bacteria and viruses from water at flow rates more than 200 times faster than virus-rated membranes that remove particles by sieving. Since the new filter s pore size is rather large compared to other membranes, it is also less susceptible to clogging by small particles. In September 2002, Argonide began a Phase II SBIR project with Johnson to develop a full-size cartridge capable of serving a full space crew. This effort, which is still ongoing, enabled the company to demonstrate that its filter media is an efficient absorbent for DNA and RNA.
Bottari, Fabio; Oliveri, Paolo; Ugo, Paolo
2014-02-15
A nanostructured electrochemical biosensor for detecting proteins of interest in work of art, in particular in tempera paintings, is presented. To determine egg yolk we focus here on the determination of immunoglobulin IgY. The transducers are nanoelectrode ensembles (NEEs), prepared via membrane templated electroless deposition of gold. Because of their geometrical and diffusion characteristics, NEEs are characterized by significantly low detection limits, moreover they display the capability of capturing proteins by interaction with the polycarbonate membrane of the NEE. At first, the proteic component of the paint is extracted by ultrasonication in an aqueous buffer, then IgY is captured by incubation on the NEE. The immunoglobulin is detected by treatment with anti-IgY labeled with horse radish peroxidase (Anti-IgY-HRP). The binding of the Anti-IgY-HRP is detected by recording the electrocatalytic signal caused by addition of H2O2 and methylene blue. The sensor detection capabilities are tested by analyzing both paint models, prepared in the lab, and real samples, from paintings of the XVIII-XX century. Multivariate exploratory analysis is applied to classify the voltammetric patterns, confirming the capability to differentiate egg-yolk tempera from other kind of tempera binders as well as from acrylic or oil paints. © 2013 Elsevier B.V. All rights reserved.
Zhao, Xinyan; Dong, Tao
2012-10-16
This study reports a quantitative nucleic acid sequence-based amplification (Q-NASBA) microfluidic platform composed of a membrane-based sampling module, a sample preparation cassette, and a 24-channel Q-NASBA chip for environmental investigations on aquatic microorganisms. This low-cost and highly efficient sampling module, having seamless connection with the subsequent steps of sample preparation and quantitative detection, is designed for the collection of microbial communities from aquatic environments. Eight kinds of commercial membrane filters are relevantly analyzed using Saccharomyces cerevisiae, Escherichia coli, and Staphylococcus aureus as model microorganisms. After the microorganisms are concentrated on the membrane filters, the retentate can be easily conserved in a transport medium (TM) buffer and sent to a remote laboratory. A Q-NASBA-oriented sample preparation cassette is originally designed to extract DNA/RNA molecules directly from the captured cells on the membranes. Sequentially, the extract is analyzed within Q-NASBA chips that are compatible with common microplate readers in laboratories. Particularly, a novel analytical algorithmic method is developed for simple but robust on-chip Q-NASBA assays. The reported multifunctional microfluidic system could detect a few microorganisms quantitatively and simultaneously. Further research should be conducted to simplify and standardize ecological investigations on aquatic environments.
Particle bounce in a personal cascade impactor: a field evaluation.
Hinds, W C; Liu, W C; Froines, J R
1985-09-01
The collection characteristics of five types of substrates (collection surfaces) used in personal cascade impactors were evaluated for particle bounce in the laboratory with lead dioxide dust, and in the field with brass pouring fume and brass grinding dust. The substrates tested were uncoated stainless steel, silicon grease-coated stainless steel, oil-saturated Millipore membrane filter, oil-saturated Teflon membrane filter and oil-saturated sintered stainless steel. The use of coated and uncoated stainless steel plates to collect lead dioxide dust produced no difference in measured mass median diameter (MMD); however, with brass grinding dust, there was a 50% decrease in measured MMD when uncoated stainless steel substrates were used, as compared with coated stainless steel substrates. Oil-saturated Millipore membrane surfaces gave consistently lower MMDs than coated stainless steel surfaces. Coated and uncoated stainless steel gave similar MMDs when used to sample brass pouring fume. Oil-saturated Teflon membrane and oil-saturated sintered metal, surfaces for which the collection efficiency is presumed to be independent of the particle loading, gave MMDs similar to those measured for grease-coated stainless steel. The implications of these comparisons are discussed. It is concluded that bounce characteristics are strongly dependent on aerosol material and the suitability of collection surfaces needs to be determined by field evaluation.
Maeng, Sung Kyu; Timmes, Thomas C; Kim, Hyun-Chul
2017-10-01
Two different quaternary amine polymers were examined as primary coagulants for the removal of natural organic matter (NOM) and concurrent production of flocs favorable for downstream membrane separation. The primary issue explored was the relationship between various coagulation conditions on the floc characteristics and the subsequent performance of microfiltration when filtering coagulated NOM. The size distribution and morphological properties of flocs formed through the coagulation of NOM were characterized and the effects of polymer type and dose on these characteristics were also examined. Coagulation of NOM using polydiallyldimethyl-ammonium chloride (pDADMAC) produced looser and less settleable flocs compared to dosing the equivalent amount of epichlorohydrin/dimethylamine (epi/DMA). This was associated with the formation of a relatively denser cake layer on the top of the membrane for the filtration of NOM coagulated with epi/DMA. The charge neutralization coagulation condition with the polymers removed almost all of the fouling tendency that had occurred when filtering raw NOM. The median diameter and the fractal dimension of the flocs produced increased as the zeta potential approached zero, which resulted in the formation of a cake layer that was easily removed from the surface of the membrane.
Ferraz, Aline S; Belo, Elza F T; Coutinho, Ligia M C C; Oliveira, Ana P; Carmo, Andréia M S; Franco, Daniele L; Ferreira, Tatiane; Yto, André Y; Machado, Marta S F; Scola, Monica C G; De Gaspari, Elizabeth
2008-03-06
A simple filter paper method was developed for, the transport and storage of monoclonal antibodies (Mabs) at room temperature or -20 degrees C after spotting on filter paper, for subsequent serotyping of outer membrane antigens of N.meningitidis by dot-blot ELISA. Monoclonal antibodies (Mabs) were spotted within a 0.5-1 cm diameter area of Whatman grade 903 paper, which were stored individually at room temperature or at -20 degrees C. These MAbs were stored and analyzed after periods of one week, 4 weeks, 12 months, or 13 years in the case of frozen Mab aliquots, or after 4 weeks at -20 degrees C or at room temperature (RT) in the case of Mabs dried on filter paper strips. Assays were performed in parallel using dot-blot ELISA. In addition to the MAbs specific for serotyping class 1, 2 or 3, we used a larger number of Mabs for polysaccharides, lipooligosaccharides (LOS), class 5 and cross-reactive antigens for native outer membrane of N.meningitidis. The Mabs dried on filter paper were eluted with phosphate-buffered saline (PBS) containing 0.2% gelatin. Mabs of the isotypes IgG and IgM dried on filter papers were not affected by duration of storage. The detection by serotyping Mabs was generally consistent for dried filter paper MAb samples stored frozen for over 1 year at -20 degrees C, and although decreased reactive antibody titers were found after storage, this did not interfere with the specificity of the Mabs used after 13 years as dry spots on filter paper. The use of filter paper is an inexpensive and convenient method for collecting, storing, and transporting Mab samples for serotyping studies. In addition, the samples occupy little space and can be readily transported without freezing. The efficiency of using immunoglobulin G (IgG) or M (IgM) eluted was found to be consistent with measurement of IgG or IgM titers in most corresponding, ascites Mabs stored frozen for over 1 year. The application of meningococcal typing methods and designations depend on the question being asked.
Zimmermann, R; Iturriaga, R; Becker-Birck, J
1978-01-01
The electron transport system of respiring organisms reduces 2-(p-iodophenyl)-3-(p-nitrophenyl)-5-phenyl tetrazolium chloride (INT) to INT-formazan. Respiring bacteria deposit accumulated INT-formazan intracellularly as dark red spots. Corresponding to electron transport system activity, these deposits attain a size and a degree of optical density which allows them to be examined by light microscopy. If polycarbonate filters and epifluorescence microscopy are applied to analyze an INT-treated water sample, it is possible to differentiate between respiring and apparently nonrespiring bacteria. This differentiation, which permits determinations of the total number of bacteria and the proportion thereof involved in respiration, is realized directly within one and the same microscopic image. Initial applications of the present method for hydrobiological purposes showed that the proportion of respiring aquatic bacteria ranged between 6 to 12% (samples taken from coastal areas of the Baltic Sea) and 5 to 36% (samples taken from freshwater lakes and ponds). Cells of 1.6 to 2.4 micrometer (freshwater) and 0.4 micrometer (Baltic Sea) account for the highest proportion of respiring bacteria. Images PMID:367268
Towards fully automated Identification of Vesicle-Membrane Fusion Events in TIRF Microscopy
NASA Astrophysics Data System (ADS)
Vallotton, Pascal; James, David E.; Hughes, William E.
2007-11-01
Total Internal Reflection Fluorescence Microscopy (TIRFM) is imposing itself as the tool of choice for studying biological activity in close proximity to the plasma membrane. For example, the exquisite selectivity of TIRFM allows monitoring the diffusion of GFP-phogrin vesicles and their recruitment to the plasma membrane in pancreatic β-cells. We present a novel computer vision system for automatically identifying the elusive fusion events of GFP-phogrin vesicles with the plasma membrane. Our method is based on robust object tracking and matched filtering. It should accelerate the quantification of TIRFM data and allow the extraction of more biological information from image data to support research in diabetes and obesity.
Development of emission factors for polycarbonate processing.
Rhodes, Verne L; Kriek, George; Lazear, Nelson; Kasakevich, Jean; Martinko, Marie; Heggs, R P; Holdren, M W; Wisbith, A S; Keigley, G W; Williams, J D; Chuang, J C; Satola, J R
2002-07-01
Emission factors for selected volatile organic compounds (VOCs) and particulate emissions were developed while processing eight commercial grades of polycarbonate (PC) and one grade of a PC/acrylonitrile-butadiene-styrene (ABS) blend. A small commercial-type extruder was used, and the extrusion temperature was held constant at 304 degrees C. An emission factor was calculated for each substance measured and is reported as pounds released to the atmosphere/million pounds of polymer resin processed [ppm (wt/wt)]. Scaled to production volumes, these emission factors can be used by processors to estimate emission quantities from similar PC processing operations.
Near-failure detonation behavior of vapor-deposited hexanitrostilbene (HNS) films
NASA Astrophysics Data System (ADS)
Knepper, Robert; Wixom, Ryan R.; Marquez, Michael P.; Tappan, Alexander S.
2017-01-01
Hexanitrostilbene (HNS) films were deposited onto polycarbonate substrates using vacuum thermal sublimation. The deposition conditions were varied in order to alter porosity in the films, and the resulting microstructures were quantified by analyzing ion-polished cross-sections using scanning electron microscopy. The effects of these changes in microstructure on detonation velocity and the critical thickness needed to sustain detonation were determined. The polycarbonate substrates also acted as recording plates for detonation experiments, and films near the critical thickness displayed distinct patterns in the dent tracks that indicate instabilities in the detonation front when approaching failure conditions.
Functionalization of polycarbonate with proteins; open-tubular enzymatic microreactors.
Ogończyk, D; Jankowski, P; Garstecki, P
2012-08-07
This paper examines a set of techniques for the immobilization of enzymes on the surface of microchannels fabricated in polycarbonate (PC). Our experiments identify the method that uses combined physico-chemical immobilization on a layer of polyethyleneimine (PEI) as a reproducible vista for the robust immobilization of proteins. As an example, we demonstrate the fabrication, throughput and stability of an open-tubular reactor draped with alkaline phosphatase (ALP, EC 3.1.3.1) as a model enzyme. As PC is suitable for industrial applications the method could potentially be used to immobilize proteins in numbered-up implementations.
A history of semi-active laser dome and window materials
NASA Astrophysics Data System (ADS)
Sullivan, Roger M.
2014-05-01
Semi-Active Laser (SAL) guidance systems were developed starting in the mid-1960's and today form an important class of precision guided weapons. The laser wavelengths generally fall in the short wave infrared region of the spectrum. Relative to passive, image based, infrared seekers the optical demands placed on the domes or windows of SAL seekers is very modest, allowing the use of low cost, easily manufactured materials, such as polycarbonate. This paper will examine the transition of SAL window and dome science and technology from the laboratory to battlefield, with special emphasis on the story of polycarbonate domes.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Young Cho; Alexander Fridman
2009-04-02
The overall objective of the present work was to develop technologies to reduce freshwater consumption in a cooling tower of coal-based power plant so that one could significantly reduce the need of make-up water. The specific goal was to develop a scale prevention technology based an integrated system of physical water treatment (PWT) and a novel filtration method so that one could reduce the need for the water blowdown, which accounts approximately 30% of water loss in a cooling tower. The present study investigated if a pulsed spark discharge in water could be used to remove deposits from the filtermore » membrane. The test setup included a circulating water loop and a pulsed power system. The present experiments used artificially hardened water with hardness of 1,000 mg/L of CaCO{sub 3} made from a mixture of calcium chloride (CaCl{sub 2}) and sodium carbonate (Na{sub 2}CO{sub 3}) in order to produce calcium carbonate deposits on the filter membrane. Spark discharge in water was found to produce strong shockwaves in water, and the efficiency of the spark discharge in cleaning filter surface was evaluated by measuring the pressure drop across the filter over time. Results showed that the pressure drop could be reduced to the value corresponding to the initial clean state and after that the filter could be maintained at the initial state almost indefinitely, confirming the validity of the present concept of pulsed spark discharge in water to clean dirty filter. The present study also investigated the effect of a plasma-assisted self-cleaning filter on the performance of physical water treatment (PWT) solenoid coil for the mitigation of mineral fouling in a concentric counterflow heat exchanger. The self-cleaning filter utilized shockwaves produced by pulse-spark discharges in water to continuously remove scale deposits from the surface of the filter, thus keeping the pressure drop across the filter at a relatively low value. Artificial hard water was used in the present fouling experiments for three different cases: no treatment, PWT coil only, and PWT coil plus self-cleaning filter. Fouling resistances decreased by 59-72% for the combined case of PWT coil plus filter compared with the values for no-treatment cases. SEM photographs showed much smaller particle sizes for the combined case of PWT coil plus filter as larger particles were continuously removed from circulating water by the filter. The x-ray diffraction data showed calcite crystal structures for all three cases.« less
NASA Astrophysics Data System (ADS)
Deacon, L. J.; Pankhurst, L. J.; Drew, G. H.; Hayes, E. T.; Jackson, S.; Longhurst, P. J.; Longhurst, J. W. S.; Liu, J.; Pollard, S. J. T.; Tyrrel, S. F.
Information on the particle size distribution of bioaerosols emitted from open air composting operations is valuable in evaluating potential health impacts and is a requirement for improved dispersion simulation modelling. The membrane filter method was used to study the particle size distribution of Aspergillus fumigatus spores in air 50 m downwind of a green waste compost screening operation at a commercial facility. The highest concentrations (approximately 8 × 10 4 CFU m -3) of culturable spores were found on filters with pore diameters in the range 1-2 μm which suggests that the majority of spores are emitted as single cells. The findings were compared to published data collected using an Andersen sampler. Results were significantly correlated ( p < 0.01) indicating that the two methods are directly comparable across all particles sizes for Aspergillus spores.
Method for producing a selectively permeable separation module
Stone, Mark L.; Orme, Christopher J.; Peterson, Eric S.
2000-03-14
A method and apparatus is provided for casting a polymeric membrane on the inside surface of porous tubes to provide a permeate filter system capable of withstanding hostile operating conditions and having excellent selectivity capabilities. Any polymer in solution, by either solvent means or melt processing means, is capable of being used in the present invention to form a thin polymer membrane having uniform thickness on the inside surface of a porous tube. Multiple tubes configured as a tubular module can also be coated with the polymer solution. By positioning the longitudinal axis of the tubes in a substantially horizontal position and rotating the tube about the longitudinal axis, the polymer solution coats the inside surface of the porous tubes without substantially infiltrating the pores of the porous tubes, thereby providing a permeate filter system having enhanced separation capabilities.