Scalable bonding of nanofibrous polytetrafluoroethylene (PTFE) membranes on microstructures
NASA Astrophysics Data System (ADS)
Mortazavi, Mehdi; Fazeli, Abdolreza; Moghaddam, Saeed
2018-01-01
Expanded polytetrafluoroethylene (ePTFE) nanofibrous membranes exhibit high porosity (80%-90%), high gas permeability, chemical inertness, and superhydrophobicity, which makes them a suitable choice in many demanding fields including industrial filtration, medical implants, bio-/nano- sensors/actuators and microanalysis (i.e. lab-on-a-chip). However, one of the major challenges that inhibit implementation of such membranes is their inability to bond to other materials due to their intrinsic low surface energy and chemical inertness. Prior attempts to improve adhesion of ePTFE membranes to other surfaces involved surface chemical treatments which have not been successful due to degradation of the mechanical integrity and the breakthrough pressure of the membrane. Here, we report a simple and scalable method of bonding ePTFE membranes to different surfaces via the introduction of an intermediate adhesive layer. While a variety of adhesives can be used with this technique, the highest bonding performance is obtained for adhesives that have moderate contact angles with the substrate and low contact angles with the membrane. A thin layer of an adhesive can be uniformly applied onto micro-patterned substrates with feature sizes down to 5 µm using a roll-coating process. Membrane-based microchannel and micropillar devices with burst pressures of up to 200 kPa have been successfully fabricated and tested. A thin layer of the membrane remains attached to the substrate after debonding, suggesting that mechanical interlocking through nanofiber engagement is the main mechanism of adhesion.
The biodurability of covering materials for metallic stents in a bile flow phantom.
Bang, Byoung Wook; Jeong, Seok; Lee, Don Haeng; Lee, Jung Il; Lee, Se Chul; Kang, Sung-Gwon
2012-04-01
Covered biliary metal stents have been introduced for the purpose of overcoming tumor ingrowth and treatment of benign biliary stricture. The aim of this study was to evaluate the biodurability of three commercially available biliary metal stent covering materials [e-PTFE (expanded polytetrafluoroethylene), silicone, and polyurethane] in a bile flow phantom. By operation of a peristaltic pump, human bile was circulated continuously in an experimental perfusion system containing covered metal stents. Each stent was removed, respectively, 1, 2, 4, and 6 months after bile exposure. We performed a gross inspection of the covered stents. The covering membrane was detached from the stent and observed by scanning electron microscopy (SEM). Finally, we measured tensile and tear strength of the membranes. Bile-staining of the membrane showed gradual progression after bile exposure; however, progress was the fastest in e-PTFE. SEM examination showed that the polyurethane surface was smooth, and the silicone surface was relatively smooth. However, e-PTFE had a rough and uneven surface. After bile exposure, there were no significant changes in polyurethane and silicone; however, biofilms and microcracks were observed in e-PTFE. In contrast to a gradual decrease of tensile/tear strength of polyurethane and silicone, those of e-PTFE showed a rapid reduction despite of the strongest baseline tensile and tear strength. e-PTFE tended to form biofilms more frequently than polyurethane and silicone during bile exposure. e-PTFE seemed to be less durable than silicone and polyurethane, however, as clinically applicable material because of strong absolute tensile/tear strengths.
Higuchi, Masatoshi; Moroi, Akinori; Yoshizawa, Kunio; Kosaka, Akihiko; Ikawa, Hiroumi; Iguchi, Ran; Saida, Yuriko; Hotta, Asami; Tsutsui, Takamitsu; Ueki, Koichiro
2016-09-01
The purpose of this study was to compare bone regenerative capability following use of polytetrafluoroethylene (ePTFE) membrane against that when various densities of pore titanium meshes are used with and without low intensity pulsed ultrasound (LIPUS). Adult male white rabbits were divided into 8 groups. In 4 groups, after incising along the nasal bone, four 3 × 8 mm bone defects were made in both sides and covered by an ePTFE membrane (group E: n = 15), a high density pore titanium mesh (group H: n = 15), a low density pore titanium mesh (group L: n = 15), and no mesh (control) (group C: n = 15). Furthermore, LIPUS was irradiated after surgery in 4 groups (groups EL, HL, LL and CL, in each n = 15). The rabbits were sacrificed at 1, 2 and 8 weeks postoperative, and formalin-fixed specimens were embedded in acrylic resin. The specimens were stained with hematoxylin and eosin. For immunohistochemical analysis, the specimens were treated with bone morphogenetic protein (BMP)-2 antibody. Group H had significantly higher values than groups L, E, and C regarding bone area ratio and labeling index of BMP-2 positive cells (P < 0.05). Furthermore, Group HL also had significantly higher values than the other groups regarding bone area ratio and labeling index of BMP-2 positive cells at 1, 2 and 8 weeks postoperative (P < 0.05). The results suggested that high density pore titanium mesh could induce new bone regeneration more than low density pore titanium mesh and ePTFE membrane. New bone formation may increase following LIPUS application. Copyright © 2016 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.
Immunolocalization of markers for bone formation during guided bone regeneration in osteopenic rats
TERA, Tábata de Mello; NASCIMENTO, Rodrigo Dias; do PRADO, Renata Falchete; SANTAMARIA, Mauro Pedrine; JARDINI, Maria Aparecida Neves
2014-01-01
Objective The aim of this paper was to evaluate the repair of onlay autogenous bone grafts covered or not covered by an expanded polytetrafluoroethylene (e-PTFE) membrane using immunohistochemistry in rats with induced estrogen deficiency. Material and Methods Eighty female rats were randomly divided into two groups: ovariectomized (OVX) and with a simulation of the surgical procedure (SHAM). Each of these groups was again divided into groups with either placement of an autogenous bone graft alone (BG) or an autogenous bone graft associated with an e-PTFE membrane (BGM). Animals were euthanized on days 0, 7, 21, 45, and 60. The specimens were subjected to immunohistochemistry for bone sialoprotein (BSP), osteonectin (ONC), and osteocalcin (OCC). Results All groups (OVX+BG, OVX+BMG, SHAM+BG, and SHAM+BMG) showed greater bone formation, observed between 7 and 21 days, when BSP and ONC staining were more intense. At the 45-day, the bone graft showed direct bonding to the recipient bed in all specimens. The ONC and OCC showed more expressed in granulation tissue, in the membrane groups, independently of estrogen deficiency. Conclusions The expression of bone forming markers was not negatively influenced by estrogen deficiency. However, the markers could be influenced by the presence of the e-PTFE membrane. PMID:25591022
DOE Office of Scientific and Technical Information (OSTI.GOV)
El Backly, Rania M.; IRCCS AOU San Martino–IST Istituto Nazionale per la Ricerca sul Cancro, Genova; Faculty of Dentistry, Alexandria University, Alexandria
The present work defines a modified critical size rabbit ulna defect model for bone regeneration in which a non-resorbable barrier membrane was used to separate the radius from the ulna to create a valid model for evaluation of tissue-engineered periosteal substitutes. Eight rabbits divided into two groups were used. Critical defects (15 mm) were made in the ulna completely eliminating periosteum. For group I, defects were filled with a nanohydroxyapatite poly(ester urethane) scaffold soaked in PBS and left as such (group Ia) or wrapped with a tissue-engineered periosteal substitute (group Ib). For group II, an expanded-polytetrafluoroethylene (e-PTFE) (GORE-TEX{sup ®}) membranemore » was inserted around the radius then the defects received either scaffold alone (group IIa) or scaffold wrapped with periosteal substitute (group IIb). Animals were euthanized after 12–16 weeks, and bone regeneration was evaluated by radiography, computed microtomography (μCT), and histology. In the first group, we observed formation of radio-ulnar synostosis irrespective of the treatment. This was completely eliminated upon placement of the e-PTFE (GORE-TEX{sup ®}) membrane in the second group of animals. In conclusion, modification of the model using a non-resorbable e-PTFE membrane to isolate the ulna from the radius was a valuable addition allowing for objective evaluation of the tissue-engineered periosteal substitute.« less
Hsu, Shih-Chao; Thorat, Ashok; Yang, Horng-Ren; Poon, Kin-Shing; Li, Ping-Chun; Yeh, Chun-Chieh; Chen, Te-Hung; Jeng, Long-Bin
2017-07-06
BACKGROUND Our recent studies have highlighted the importance and safety of backtable venoplasty for middle hepatic vein (MHV) and inferior right hepatic veins (IRHV) reconstruction using expanded polytetrafluoroethylene (ePTFE) vascular grafts. In this study, we aim to analyze the complications associated with ePTFE graft use and discuss the management of the rare, but, potentially life threatening complications directly related to ePTFE conduits. MATERIAL AND METHODS From January 2012 to October 2015 a total of 397 patients underwent living donor liver transplantation (LDLT). The ePTFE vascular grafts were used during the backtable venoplasty for outflow reconstruction in 262 of the liver allografts. Recipients who developed ePTFE-related complications were analyzed. RESULTS ePTFE-related complications developed in 1.52% (4/262) of the patients. One patient (0.38%) developed complete thrombosis with sepsis at 24 months post-transplantation and died due to multiorgan failure. Three patients (1.1%) developed graft migration into the second portion of the duodenum, without overt peritonitis. Surgical exploration and ePTFE graft removal was done in all the patients. One patient died due to overwhelming sepsis. CONCLUSIONS ePTFE graft migration into the duodenum causing perforation is a new set of complications that has been recently described in LDLT and can be treated effectively by surgical removal of the infected vascular graft and duodenal perforation closure. Despite of such complications, in our experience, ePTFE use in LDLT continues to have wide safety margin, with a complication rate of only 1.52%.
Furukawa, K S; Ushida, T; Sugano, H; Tamaki, T; Ohshima, N; Tateishi, T
2000-01-01
We visualized in real-time platelets adhering to the surface of three representative biomaterials, by using an apparatus consisting of a modified cone and plate rheometer combined with an upright epifluorescence microscope under two shear flows (0.1 and 5.0 dyne/cm2). The materials were expanded polytetrafluoroethylene (ePTFE), silicone sheet, and a monolayer of bovine endothelial cells (ECs) formed on glass, all of which are opaque materials used for artificial blood vessels and medical devices. According to quantitative analysis, the monolayer of ECs formed on glass had better blood compatibility than did either the ePTFE or the silicone sheet under shear flow conditions. Under a shear flow condition of 0.1 dyne/cm2, platelet adhesion was silicone sheet > ePTFE. In contrast, under a shear flow condition of 5.0 dyne/cm2, ePTFE > silicone sheet. These results indicate that the intensity of shear stress could modify the order of hemocompatibility of the materials. Therefore, direct observation of platelet adhesion under shear flow conditions is indispensable for testing and screening biomaterials and for providing a precise quantitative evaluation of platelet adhesion.
Tordoir, J H; Hofstra, L; Leunissen, K M; Kitslaar, P J
1995-04-01
The purpose of this study was to evaluate the results and complications of standard ePTFE versus stretch ePTFE AV fistulas. Prospective randomised trial. University Hospital. During a 2-year period 37 patients received 17 stretch and 20 standard ePTFE graft AV fistulas. Patients were evaluated for the occurrence of complications and graft patency. Regular Duplex scans were performed to detect stenoses in the fistula circuit. Thrombotic events occurred in 40% of the standard ePTFE grafts, compared to 12% of the stretch ePTFE prostheses (p < 0.001). The incidence of puncture complications was similar in both groups. The cumulative primary patency rate in the stretch ePTFE group was significantly higher compared to the standard ePTFE group (1-year patency rates of 59% and 29%, respectively; p < 0.01). No differences in the duration of puncture site bleeding were observed. Duplex scanning showed a significantly greater number of stenoses in the standard ePTFE grafts. The new stretch ePTFE prosthesis has better primary patency rates and less stenoses due to intimal hyperplasia as compared to standard ePTFE grafts.
Joo, Yeon Hee; Jang, Yong Ju
2016-09-01
Dorsal augmentation material includes alloplastic implants and autologous tissues. However, there has been no comparison to date of dorsal augmentation using different materials performed by the same surgeon. To compare the aesthetic outcomes and complications of dorsal augmentation using expanded polytetrafluoroethylene (ePTFE) and autologous costal cartilage (ACC) in rhinoplasty. A retrospective review of the medical records of 244 patients who underwent dorsal augmentation performed by the same surgeon at the Asan Medical Center using ePTFE or ACC from March 1, 2003, through September 31, 2015. Patient demographics and surgical procedures were analyzed. The aesthetic outcomes were scored from 1 (worst) to 4 (best) by 3 otolaryngologists. Changes in dorsal height and radix height were measured by comparing preoperative and postoperative profile views. Postoperative complications were also evaluated. A total of 244 patients who underwent augmentation rhinoplasty were reviewed in this study, including 141 men (57.8%) and 103 women (42.2%). The ePTFE group included 176 patients, and the ACC group comprised 68 patients. In the ePTFE and ACC groups, 96 patients (54.5%) and 45 patients (66.2%) were male, respectively. The patient ages ranged from 11 to 69 years, with a mean (SD) age of 30.3 (11.49) years in the ePTFE group and 36.04 (12.65) years in the ACC group. The mean (SD) aesthetic outcome scores were comparable between the 2 groups: 2.99 (0.05) in the ePTFE group and 2.99 (0.06) in the ACC group (P = .93). The change of dorsal (2.64% in ePTFE group and 5.82% in ACC group) and radix (3.62% in ePTFE group and 3.77% in ACC group) heights were significantly increased after augmentation in both groups (P < .001) even though the dorsal height of the ACC group after augmentation showed a significantly greater increase compared to the ePTFE group (P < .001). However, the complication rate was significantly higher in the ACC group: 4.0% in ePTFE group and 11.8% in ACC group (P = .02). Dorsal augmentation with ACC produces similar aesthetic outcomes but a higher complication rate than dorsal augmentation with ePTFE. This higher complication rate may justify the use of ePTFE implants for dorsal augmentation in Asian patients undergoing rhinoplasty. 3.
A new method for the adjustment of neochordal length: the adjustable slip knot technique.
Yano, Mitsuhiro; Sakaguchi, Syuuhei; Furukawa, Kohji; Nakamura, Eisaku
2015-08-01
The use of expanded polytetrafluoroethylene (ePTFE) sutures for the correction of mitral valve prolapse has become a standardized procedure. Adjustment of neochordal length is crucial to the efficacy of this technique. Various methods have been described for this purpose; however, the fine adjustment of neochordal length is technically challenging. We describe a simple and effective technique for the implantation of neochordae, which we have termed the 'adjustable slip knot technique'. The first step of this technique is reinforcement of the papillary muscle by a Teflon pledget with or without polytetrafluoroethylene (CV-4) loops. The second step is the formation of a neochordal loop by introducing an ePTFE suture between the affected mitral leaflet and the papillary muscle or ePTFE loops. The third step is the adjustment of the length of neochordae. The formation of a slip knot in one arm of the ePTFE suture is the pivot of this technique. The neochordal loop can be constricted by the application of tension to one arm of the suture. We applied this technique in 5 patients with satisfactory results. © The Author 2015. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.
Evaluation of novel resorbable membranes for bone augmentation in a rat model.
Zeng, Ni; van Leeuwen, Anne; Yuan, Huipin; Bos, Ruud R M; Grijpma, Dirk W; Kuijer, Roel
2016-02-01
Our study compared two novel, biodegradable poly(trimethylene carbonate) (PTMC) barrier membranes to clinically applied barrier membranes in maintaining volume of block autologous bone grafts in a rat mandible model. Two hundred and forty rats were included in this study. Block autologous bone grafts of 5 mm in diameter were harvested from the mandibular angles and transplanted onto the contralateral side. The bone grafts were either covered with a membrane or left uncovered. The applied membranes included pure PTMC membranes, biphasic calcium phosphate (BCP) incorporated PTMC composite membranes, expanded poly(tetrafluoroethylene) (e-PTFE) membranes (Tex) and collagen membranes (Geistlich Bio-Gide). After 2, 4 and 12 weeks, the rat mandibles were retrieved and analysed by histological evaluation and μCT quantification. The histological evaluation revealed that in time the block autologous bone graft was well integrated to the recipient bone via gradually maturing newly formed bone and did not show signs of resorption, independent of membrane coverage or types of membrane. μCT quantification showed the volume of the bone graft and recipient bone together was maintained by new bone formation and recipient bone resorption. Our study showed that the use of PTMC membranes and PTMC-BCP composite membranes resulted in similar bone remodelling to the collagen membranes and e-PTFE membranes and that the use of barrier membranes did not interfere with bone remodelling of the bone grafts and recipient bones. However, the used barrier membranes seemed not to contribute in maintaining the volume of block autologous bone grafts. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Recovery of ammonia from poultry litter using flat gas permeable membranes.
Rothrock, M J; Szögi, A A; Vanotti, M B
2013-06-01
The use of flat gas-permeable membranes was investigated as components of a new process to capture and recover ammonia (NH3) in poultry houses. This process includes the passage of gaseous NH3 through a microporous hydrophobic membrane, capture with a circulating dilute acid on the other side of the membrane, and production of a concentrated ammonium (NH4) salt. Bench- and pilot-scale prototype systems using flat expanded polytetrafluoroethylene (ePTFE) membranes and a sulfuric acid solution consistently reduced headspace NH3 concentrations from 70% to 97% and recovered 88% to 100% of the NH3 volatilized from poultry litter. The potential benefits of this technology include cleaner air inside poultry houses, reduced ventilation costs, and a concentrated liquid ammonium salt that can be used as a plant nutrient solution. Published by Elsevier Ltd.
Jin, Young Ju; Kang, Sunah; Park, Pona; Choi, Dongkil; Kim, Dae Woo; Jung, Dongwook; Koh, Jaemoon; Jeon, Joohee; Lee, Myoungjin; Ham, Jiyeon; Seo, Ji-Hun; Jin, Hong-Ryul; Lee, Yan
2017-06-07
Expanded polytetrafluoroethylene (ePTFE), also known as Gore-Tex, is widely used as an implantable biomaterial in biomedical applications because of its favorable mechanical properties and biochemical inertness. However, infection and inflammation are two major complications with ePTFE implantations, because pathogenic bacteria can inhabit the microsized pores, without clearance by host immune cells, and the limited biocompatibility can induce foreign body reactions. To minimize these complications, we covalently grafted a biomembrane-mimic polymer, poly(2-methacryloyloxylethyl phosphorylcholine) (PMPC), by partial defluorination followed by UV-induced polymerization with cross-linkers on the ePTFE surface. PMPC grafting greatly reduced serum protein adsorption as well as fibroblast adhesion on the ePTFE surface. Moreover, the PMPC-grafted ePTFE surface exhibited a dramatic inhibition of the adhesion and growth of Staphylococcus aureus, a typical pathogenic bacterium in ePTFE implants, in the porous network. On the basis of an analysis of immune cells and inflammation-related factors, i.e., transforming growth factor-β (TGF-β) and myeloperoxidase (MPO), we confirmed that inflammation was efficiently alleviated in tissues around PMPC-grafted ePTFE plates implanted in the backs of rats. Covalent PMPC may be an effective strategy for promoting anti-inflammatory and antibacterial functions in ePTFE implants and to reduce side effects in biomedical applications of ePTFE.
Souza, Sérgio L S; Macedo, Guilherme O; Silveira E Souza, Adriana M M; Taba, Mário; Novaes, Arthur B; Oliver, Constance; Jamur, Maria C; Correa, Vani M A
2013-10-01
Previous studies have shown that there is a relationship between periodontal disease and the distribution of collagen fibers. This study evaluated the distribution of collagen types I and III in regenerated bone and periodontal ligament, comparing them to the tissues near the regenerated area and to the healthy periodontium. In the third (P3) and fourth (P4) mandibular premolars of 5 healthy mongrel dogs, bilaterally, buccal class 2 furcation lesions were surgically created and chronified for 3 weeks. After that, full flaps were elevated and expanded polytetrafluoroethylene (e-PTFE) membranes were adapted, sutured and recovered by the flaps. Two weeks after surgery, two membranes on the same side were removed and the other membranes were removed four weeks after surgery. The dogs were euthanized at 12 weeks following placement of the e-PTFE membranes. P3 and P4 teeth as well as the second premolars (healthy control teeth) and their periodontal tissues were removed and histologically processed for Collagen Quantification (COLQ). The amount of type III collagen was higher in native bone compared to the regenerated area. For periodontal ligament, COLQ for type I collagen showed statistically significant differences (Tukeys's Multiple Comparison, p⟨0.05) between the regenerated groups and the control group. These differences were not found for type III COLQ. There are significant differences in collagen distribution among the regenerated, native and control tissues. Membrane removal 2 or 4 weeks postoperatively did not influence the collagen composition.
Does expanded polytetrafluoroethylene mesh really shrink after laparoscopic ventral hernia repair?
Carter, P R; LeBlanc, K A; Hausmann, M G; Whitaker, J M; Rhynes, V K; Kleinpeter, K P; Allain, B W
2012-06-01
The shrinkage of mesh has been cited as a possible explanation for hernia recurrence. Expanded polytetrafluoroethylene (ePTFE) is unique in that it can be visualized on computed tomography (CT). Some animal studies have shown a greater than 40% rate of contraction of ePTFE; however, very few human studies have been performed. A total of 815 laparoscopic incisional/ventral hernia (LIVH) repairs were performed by a single surgical group. DualMesh Plus (ePTFE) (WL Gore & Associates, Newark, DE) was placed in the majority of these patients using both transfascial sutures and tack fixation. Fifty-eight patients had postoperative CTs of the abdomen and pelvis with ePTFE and known transverse diameter of the implanted mesh. The prosthesis was measured on the CT using the AquariusNet software program (TeraRecon, San Mateo, CA), which outlines the mesh and calculates the total length. Data were collected regarding the original mesh size, known linear dimension of mesh, seroma formation, and time interval since mesh implantation in months. The mean shrinkage rate was 6.7%. The duration of implantation ranged from 6 weeks to 78 months, with a median of 15 months. Seroma was seen in 8.6% (5) of patients. No relationship was identified between the percentage of shrinkage and the original mesh size (P = 0.78), duration of time implanted (P = 0.57), or seroma formation (P = 0.074). In 27.5% (16) of patients, no shrinkage of mesh was identified. Of the patients who did experience mesh shrinkage, the range of shrinkage was 2.6-25%. Our results are markedly different from animal studies and show that ePTFE has minimal shrinkage after LIVH repair. The use of transfascial sutures in addition to tack fixation may have an implication on the mesh contraction rates.
Beimers, Lijkele; Lam, Patrick H; Murrell, George A C
2014-10-01
This study investigated the biomechanical effects of expanded polytetrafluoroethylene (ePTFE) suture augmentation patches in rotator cuff repair constructs. The infraspinatus tendon in 24 cadaveric ovine shoulders was repaired using an inverted horizontal mattress suture with 2 knotless bone anchors (ArthroCare, Austin, TX, USA) in a lateral-row configuration. Four different repair groups (6 per group) were created: (1) standard repair using inverted horizontal mattress sutures, (2) repair with ePTFE suture augmentations on the bursal side of the tendon, (3) repair with ePTFE suture augmentations on the articular side, and, (4) repair with ePTFE suture augmentations on both sides of the tendon. Footprint contact pressure, stiffness, and the load to failure of the repair constructs were measured. Repairs with ePTFE suture augmentations on the bursal side exerted significantly more footprint contact pressure (0.40 ± 0.01 MPa) than those on the articular side (0.34 ± 0.02 MPa, P = .04) and those on both sides (0.33 ± 0.02 MPa, P = .01). At 15 degrees of abduction, ePTFE-augmented repairs on the bursal side had higher footprint contact pressure (0.26 ± 0.03 MPa) compared with standard repairs (0.15 ± 0.02 MPa, P = .01) and with ePTFE-augmented repairs on the articular side (0.18 ± 0.02 MPa, P = .03). The ePTFE-augmented repairs on the bursal side demonstrated significantly higher failure loads (178 ± 18 N) than standard repairs (120 ± 17 N, P = .04). Inverted horizontal mattress sutures augmented with ePTFE patches on the bursal side of the tendon enhanced footprint contact pressures and the ultimate load to failure of lateral-row rotator cuff repairs in an ovine model. Copyright © 2014 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.
Engineering based assessment for a shape design of a pediatric ePTFE pulmonary conduit valve.
Tsuboko, Yusuke; Shiraishi, Yasuyuki; Yamada, Akihiro; Yambe, Tomoyuki; Miura, Hidekazu; Mura, Seitaro; Yamagishi, Masaaki
2016-08-01
The authors examined the hemodynamic characteristics of expanded polytetrafluoroethylene (ePTFE) pulmonary valved conduits quantitatively by our originally developed pediatric pulmonary mechanical circulatory system, in order to suggest the optimal shape design. The system consisted of pneumatically driven right atrium and ventricle model, a pulmonary valve chamber, and elastic pulmonary compliance model with peripheral vascular resistance units, a venous reservoir. We employed two different types of ePTFE valve and evaluated the relationship between the leaflets motion and hemodynamic characteristics by using a high-speed video camera. As a result, we successfully reproduced hemodynamic simulations in our pediatric pulmonary mock system. We confirmed that the presence of bulging sinuses in the pulmonary valved conduit reduced the transvalvular energy loss and increased the valve opening area during systolic period. Our engineering-based in vitro analysis could be useful for proposing a shape design optimization of sophisticated pediatric ePTFE pulmonary valve.
Wood, A. J.; Cozad, M. J.; Grant, D. A.; Ostdiek, A. M.; Bachman, S. L.
2014-01-01
During its tenure in vivo, synthetic mesh materials are exposed to foreign body responses, which can alter physicochemical properties of the material. Three different synthetic meshes comprised of polypropylene, expanded polytetrafluoroethylene (ePTFE), and polyethylene terephthalate (PET) materials were explanted from a single patient providing an opportunity to compare physicochemical changes between three different mesh materials in the same host. Results from infrared spectroscopy demonstrated significant oxidation in polypropylene mesh while ePTFE and PET showed slight chemical changes that may be caused by adherent scar tissue. Differential scanning calorimetry results showed a significant decrease in the heat of enthalpy and melt temperature in the polypropylene mesh while the ePTFE and PET showed little change. The presence of giant cells and plasma cells surrounding the ePTFE and PET were indicative of an active foreign body response. Scanning electron micrographs and photo micrographs displayed tissue entrapment and distortion of all three mesh materials. PMID:23371769
Hyaluronic acid enhancement of expanded polytetrafluoroethylene for small diameter vascular grafts
NASA Astrophysics Data System (ADS)
Lewis, Nicole R.
Cardiovascular disease is the leading cause of mortality and morbidity in the United States and other developed countries. In the United States alone, 8 million people are diagnosed with peripheral arterial disease per year and over 250,000 patients have coronary bypass surgery each year. Autologous blood vessels are the standard graft used in small diameter (<6mm) arterial bypass procedures. Synthetic small diameter grafts have had limited success. While polyethylene (Dacron) and expanded polytetrafluoroethylene (ePTFE) are the most commonly used small diameter synthetic vascular graft materials, there are significant limitations that make these materials unfavorable for use in the low blood flow conditions of the small diameter arteries. Specifically, Dacron and ePTFE grafts display failure due to early thrombosis or late intimal hyperplasia. With the shortage of tissue donors and the limited supply of autologous blood vessels available, there is a need for a small diameter synthetic vascular graft alternative. The aim of this research is to create and characterize ePTFE grafts prepared with hyaluronic acid (HA), evaluate thrombogenic potential of ePTFE-HA grafts, and evaluate graft mechanical properties and coating durability. The results in this work indicate the successful production of ePTFE-HA materials using a solvent infiltration technique. Surface interactions with blood show increased platelet adhesion on HA-modified surfaces, though evidence may suggest less platelet activation and erythrocyte lysis. Significant changes in mechanical properties of HA-modified ePTFE materials were observed. Further investigation into solvent selection, uniformity of HA, endothelialization, and dynamic flow testing would be beneficial in the evaluation of these materials for use in small diameter vascular graft bypass procedures.
Bunyaratavej, P; Wang, H L
2001-02-01
Collagen materials have been utilized in medicine and dentistry because of their proven biocompatability and capability of promoting wound healing. For guided tissue regeneration (GTR) procedures, collagen membranes have been shown to be comparable to non-absorbable membranes with regard to probing depth reduction, clinical attachment gain, and percent of bone fill. Although these membranes are absorbable, collagen membranes have been demonstrated to prevent epithelial down-growth along the root surfaces during the early phase of wound healing. The use of grafting material in combination with collagen membranes seems to improve clinical outcomes for furcation, but not intrabony, defects when compared to the use of membranes alone. Recently, collagen materials have also been applied in guided bone regeneration (GBR) and root coverage procedures with comparable success rates to non-absorbable expanded polytetrafluoroethylene (ePTFE) membranes and conventional subepithelial connective tissue grafts, respectively. Long-term clinical trials are still needed to further evaluate the benefits of collagen membranes in periodontal and peri-implant defects. This article will review the rationale for each indication and its related literature, both in vitro and in vivo studies. The properties that make collagen membranes attractive for use in regenerative therapy will be addressed. In addition, varieties of cross-linking techniques utilized to retard the degradation rate of collagen membranes will be discussed.
Matthews, Brent D; Pratt, Broc L; Pollinger, Harrison S; Backus, Charles L; Kercher, Kent W; Sing, R F; Heniford, B Todd
2003-10-01
The development of intra-abdominal adhesions, bowel obstruction, and enterocutaneous fistulas are potentially severe complications related to the intraperitoneal placement of prosthetic biomaterials. The purpose of this study was to determine the natural history of adhesion formation to polypropylene mesh and two types of polytetrafluoroethylene (ePTFE) mesh when placed intraperitoneally in a rabbit model that simulates laparoscopic ventral hernia repair. Thirty New Zealand white rabbits were used for this study. A 10-cm midline incision was performed for intra-abdominal access and a 2 cm x 2 cm piece of mesh (n = 60) was sewn to an intact peritoneum on each side of the midline. Two types of ePTFE mesh (Dual Mesh and modified Dual Mesh, W.L. Gore & Assoc., Flagstaff, AZ) and polypropylene mesh were compared. The rate of adhesion formation was evaluated by direct visualization using microlaparoscopy (2-mm endoscope/trocar) at 7 days, 3 weeks, 9 weeks, and 16 weeks after mesh implantation. Adhesions to the prosthetic mesh were scored for extent (%) using the Modified Diamond Scale (0 = 0%, 1
Armentano, Ricardo L; Santana, Daniel Bia; Cabrera Fischer, Edmundo I; Graf, Sebastián; Cámpos, Héctor Pérez; Germán, Yanina Zócalo; Carmen Saldías, Maria Del; Alvarez, Inés
2006-02-01
The surgical options in arterial reconstruction are: the use of autologous arteries; autologous veins; or expanded polytetrafluoroethylene (ePTFE) grafts. However, the development of intimal hyperplasia when using veins or ePTFE grafts has been associated with graft failure. Since autologous arteries are not always available, the use of cryopreserved arteries has to be considered. The aims of this study were: (a) to compare the viscoelastic properties of stored cryopreserved arteries and fresh arteries by in vitro analysis; and (b) to compare the viscoelastic properties of arteries measured non-invasively in normotensive patients, with fresh arteries, cryopreserved arteries, and ePTFE segments. The viscoelastic studies were performed in normotensive patients using stress-strain analysis with non-invasive measurement of pressure and diameter in the common carotid artery, and in vitro measurements of pressure and diameter in arteries and prostheses. The in vitro studies showed that the elastic modulus (E), viscous modulus (eta), Stiffness Index (SI), Peterson modulus (Ep), and the pulse wave velocity (PWV) values for human cryopreserved carotid arteries were similar to the values obtained non-invasively in normotensive subjects (P>0.05) and to human fresh vessels (P>0.05). In vitro, the SI, Ep, PWV, and E values of ePTFE were significantly higher than the observed values in subjects and with fresh and cryopreserved arteries (P<0.05); on the other hand the ePTFE eta values were the lowest (P<0.05). We concluded that cryopreserved arteries have similar viscoelastic properties to those obtained in vivo in the arteries of normotensive subjects and in vitro in fresh arteries. Consequently, we conclude that the cryopreservation procedure does not modify the mechanical properties of the arterial wall.
Freeman, John; Chen, Aaron; Weinberg, Roy J; Okada, Tamuru; Chen, Changyi; Lin, Peter H
2018-05-01
Bypass graft thrombosis remains a significant mode of failure in prosthetic graft revascularization. The purpose of this investigation was to evaluate the long-term thromboresistant effect of heparin-bonded expanded polytetrafluoroethylene (ePTFE) graft using Carmeda BioActive Surface technology in a canine model. Bilateral femorofemoral artery bypass grafts with ePTFE grafts were performed in 25 adult grayhound dogs. In each animal, a heparin-bonded ePTFE graft (Propaten, WL Gore) was placed on one side, whereas a control nonheparin graft was placed on the contralateral side. The graft patency was assessed at 1, 6, 12, 18, and 24 months (n = 5 per group) following the bypass. Heparin bioactivity of the graft material was analyzed. The effect of intimal hyperplasia was also assessed. All bypass grafts were patent at 1 month. Significantly greater patency rates were noted in the Propaten group compared to the control group at 12, 18, and 24 months, which were 84%, 80%, and 80% vs. 55%, 35%, and 20%, respectively (P < 0.02). There was a significant reduction in the anastomotic neointimal area and neointimal cell proliferation in Propaten grafts compared with control grafts at all groups between 6 and 24 months (P < 0.05). Heparin bioactivity as measured by antithrombin binding assay was demonstrated in the Propaten graft between 1 and 24 months. Mean heparin activities on Propaten grafts ranged from 26.3 ± 6.4 pmol/cm 2 to 18.4 ± 8.7 pmol/cm 2 between 1 and 24 months, which were significantly greater than the control group (P < 0.001). Differences between mean heparin activities of explanted Propaten graft samples at the various time points were nonsignificant (P > 0.05). Heparin-bonded ePTFE graft provides a thromboresistant surface and reduced anastomotic intimal hyperplasia at 2 years. The stable heparin bioactivity of the Propaten graft confers an advantage in long-term graft patency. Copyright © 2017 The Author(s). Published by Elsevier Inc. All rights reserved.
Zybutz, M D; Laurell, L; Rapoport, D A; Persson, G R
2000-03-01
Different types of barriers are used in guided tissue regenerative procedures. This prospective study compared resorbable citric acid ester softened polylactic acid membranes (RM) and non-resorbable expanded polytetrafluoroethylene (ePTFE) barriers (NRM) in GTR treatment of intrabony defects. 29 subjects were randomly assigned to the RM group or NRM group. Each patient received one GTR procedure. An open flap debridement (FD) was performed at another site 2 weeks later to evaluate healing potential. Clinical treatment outcomes were finally evaluated 12 months after surgery for changes of pocket depth PD, probing attachment level PAL, and probing bone level PBL, and radiographically for bone change using standardised radiographs. No differences in healing patters after surgery were found between patients in the 2 study groups as evaluated from the FD surgical procedures. NRM treated sites showed less signs of post-surgical inflammation during the 1st 4 weeks of healing than did RM treated sites (p<0.05). GTR-treated defects in the RM group, initially 7.0+/-2.2 mm deep, showed PD reduction of 3.3+/-2.2 mm, PAL gain of 2.4+/-1.8 mm, PBL gain of 2.4+/-3.7 mm (28%) and a radiographic bone fill of 2.3+/-2.4 mm. Defects treated with the NRM exhibited PD reduction of 3.1+/-2.1 mm, PAL gain of 2.4+/-0.8 mm, PBL gain of 2.2+/-1.7 mm (25%) and a radiographic bone fill of 3.3+/-2.2 mm. All improvements were statistically significant (p<0.01) but there was no difference between RM and NRM treatments for any of the efficacy variables. The results of this study indicated that there was no clinically significant difference in treatment outcomes following GTR treatment of intrabony defects with citric acid ester softened polylactic acid membranes as compared to ePTFE barriers. The overall mean inter-proximal vertical bone defect fill at 12 months as assessed from intra-oral radiographs was 44% of the original mean defect depth. Thus, no clinically significant difference in treatment outcomes was observed following GTR treatment of intrabony defects with citric acid ester softened polylactic acid membranes or ePTFE barriers.
Wilkoff, Bruce L; Belott, Peter H; Love, Charles J; Scheiner, Avram; Westlund, Randy; Rippy, Marian; Krishnan, Mohan; Norlander, Barry E; Steinhaus, Bruce; Emmanuel, Janson; Zeller, Peter J
2005-03-01
Permanent leads with shocking coils for defibrillation therapy are sometimes implanted in the coronary sinus (CS) and great cardiac vein (GCV). These shocking coils, as documented by pathologic examination of animal investigations, often become tightly encapsulated by fibrosis and can be very difficult to remove. One of three configurations of the Guidant model 7109 Perimeter coronary sinus shocking lead was implanted into the distal portion of the GCV of 24 sheep for up to 14 months. Group 1 had unmodified coils (control), group 2 had coils backfilled with medical adhesive (MA), and Group 3 had coils coated with expanded polytetrafluoroethylene (ePTFE). Eighteen leads, three from each group at 6 and 14 months were transvenously extracted from the left jugular vein. The remaining six animals were not subject to extraction. All animals were euthanized for pathological and microscopic examination. All six of the control, three of the MA, and one of the ePTFE leads required the use of an electrosurgical dissection sheath (EDS) for extraction. Five control, two MA, and none of the ePTFE leads had significant fibrotic attachments to the shocking coils. Significant trauma was observed at necropsy for those leads requiring the use of the EDS for extraction. Tissue ingrowth is a major impediment to the removal of defibrillation leads implanted in the CS and GCV of sheep. Reduction of tissue ingrowth by coating the shocking coils with ePTFE or by backfilling with MA facilitates transvenous lead removal with reduced tissue trauma.
NASA Astrophysics Data System (ADS)
Chiryatyeva, Aleksandra; Trebushat, Dmitry; Prokhorokhin, Aleksei; Khakhalkin, Vladimir; Andreev, Mark; Novokhreschenov, Aleksei; Kretov, Evgeny
2017-12-01
Cardiovascular diseases are the leading cause of death worldwide. Valvular heart disease often requires valve repair or replacement. Today, surgery uses xenograft—porcine or bovine pericardium. However, bioprosthetic valves do not ensure sufficient durability. We investigated 0.6% glutaraldehyde-treated porcine pericardium to define its properties. Using a tensile test stand, we studied characteristics of the polymeric material—expanded polytetrafluoroethylene (ePTFE)—and compared it to xenopericardium. The artificial material provides a better durability; it has higher elastic modulus and ultimate tensile strength. However, ePTFE samples demonstrated direction anisotropy due to extrusion features. It requires the enhancement of quality of the ePTFE sheet or investigation of other polymeric materials to find the adequate replacement for bioprosthetic heart valves.
2017-01-24
Objectives: Open surgical reconstruction using expanded polytetrafluoroethylene stent grafts to create a sutureless anastomosis is an alternative to...French Argyle shunt was inserted into one randomly assigned artery, with a self-expanding ePTFE stent deployed in the other. Arterial flow measurements...for histopathology were obtained during the terminal procedure. Results: Angiography revealed no difference in patency at 72 hours. The stent grafts
Fillingham, Melanie; Singh, Jessica; Burtt, Stephen; Crolla, Anna; Kinsley, Chris; MacDonald, J. Douglas
2017-01-01
Capturing ammonia from anaerobically digested manure could simultaneously decrease the adverse effects of ammonia inhibition on biogas production, reduce reactive nitrogen (N) loss to the environment, and produce mineral N fertilizer as a by-product. In this study, gas permeable membranes (GPM) were used to capture ammonia from dairy manure and digestate by the diffusion of gaseous ammonia across the membrane where ammonia is captured by diluted acid, forming an aqueous ammonium salt. A lab-scale prototype using tubular expanded polytetrafluoroethylene (ePTFE) GPM was used to (1) characterize the effect of total ammonium nitrogen (TAN) concentration, temperature, and pH on the ammonia capture rate using GPM, and (2) to evaluate the performance of a GPM system in conditions similar to a mesophilic anaerobic digester. The GPM captured ammonia at a rate between 2.2 and 6.3% of gaseous ammonia in the donor solution per day. Capture rate was faster in anaerobic digestate than raw manure. The ammonia capture rate could be predicted using non-linear regression based on the factors of total ammonium nitrogen concentration, temperature, and pH. This use of membranes shows promise in reducing the deleterious impacts of ammonia on both the efficiency of biogas production and the release of reactive N to the environment. PMID:28991162
Dilatation of aortic grafts over time: what to expect and when to be concerned.
Schroeder, Torben V; Eldrup, Nikolaj; Just, Sven; Hansen, Marc; Nyhuus, Bo; Sillesen, Henrik
2009-06-01
Dilatation of aortic prosthetic grafts is commonly reported, but most reports are anecdotal, with little objective data in the literature. We performed a prospective trial of 303 patients who underwent prosthetic graft repair for aortic aneurysm or occlusive disease, randomizing patients between insertion of a woven polyester or expanded polytetrafluoroethylene (ePTFE) graft. Patients were followed with computed tomography and ultrasonography for up to 5 years in order to assess the frequency and magnitude of postoperative dilatation. Graft dilatation was documented in patients with polyester grafts at 12 months. Thereafter and up to 60 months, polyester grafts did not dilate further. After 5 years, polyester prostheses had dilated by 25% and ePTFE by 12.5%, as determined by computed tomography imaging. These observations suggest that dilatation of prosthetic grafts is more frequent with knitted polyester grafts compared with ePTFE. Dilatation occurs within the first year after implantation and can be, in part, explained by a discrepancy between the initial nominal graft diameter and its diameter after clamp release, probably due to an in vivo adaptation of the textile structure. Interestingly, graft dilatation did not appear to be associated with an increased frequency of graft-related complications.
Hu, Yun-Tao; Pan, Xu-Dong; Zheng, Jun; Ma, Wei-Guo; Sun, Li-Zhong
2017-08-01
To date, clinically available expanded polytetrafluoro-ethylene (ePTFE) vascular grafts are suboptimal for reconstructing small caliber (D < 6 mm) arteries, owing to thrombosis in early and restenosis in late stage. Our aim in this preliminary study was to fabricate a nano-fibrous vascular graft which was biofunctionalized with VEGF 165 and heparin. The short term performance was evaluated both in vitro and in vivo. Four-mm caliber grafts were prepared by the coaxial-elctrospun technique, which consisted of poly(l-lactide-co-caprolactone) [P(LLA-CL)] collagen and elastin. Heparin and endothelial cell growth factor-165 (VEGF 165 ) were encapsulated in the core of the fibrous. Controlled release of the heparin and VEGF 165 were evaluated for 28 days. Endothelial cells were cultured on the electrospun grafts or ePTFE grafts as controls. The cellular adhesion, proliferation and morphology were examined. Electrospun or ePTFE grafts were randomly implanted into a rabbit infrarenal aortic replacement model (n = 30) for 28 days without any antiplatelet therapy. At the termination, all grafts were examined by Doppler ultrasound and then evaluated with histology and scanning electron microscopy. The cumulative release amount of heparin (6.93 ± 1.03 mg) and VEGF 165 (22.17 ± 5.56 μg) during 28 days were measured. Endothelial cells cultured on electrospun grafts showed significantly higher attachment efficiency and proliferation compared to the ePTFE ones (P < 0.001). At 2 h more ECs had attached to the P(LLA-CL)/Collagen/Elatin grafts (83.26 ± 8.02%) compared to P(LLA-CL) (67.07 ± 4.16%) and ePTFE (46.87 ± 8.85%). ECs proliferated faster on VEGF loaded grafts (O.D = 2.9 ± 1.2, n = 12) compared to ePTFE (O.D = 1.7 ± 1.0, n = 12). The patency was significantly higher in electrospun grafts (86.6%) than ePTFE grafts (40.0%) (P = 0.021). Correspondingly, the microscope images of electrospun implants showed little thrombus when compared with the ePTFE implants. Biofunctionalized electrospun graft showed surgical properties, hemocompatibility and higher short-term patency compared with the ePTFE grafts. Despite good early performances, profound study should be designed for long-term evaluation. Copyright © 2017 IJS Publishing Group Ltd. Published by Elsevier Ltd. All rights reserved.
Ward, W Kenneth; Slobodzian, Emily P; Tiekotter, Kenneth L; Wood, Michael D
2002-11-01
We addressed the effect of implant thickness, implant porosity, and polyurethane (PU) chemistry on angiogenesis and on the foreign body response in rats. The following materials were implanted subcutaneously for 7 weeks then excised for histologic analysis: a solid PU; a solid polyurethane with silicone and polyethylene oxide (PU-S-PEO); porous expanded polytetrafluoroethylene (ePTFE); and porous polyvinyl alcohol sponge (PVA). Two thicknesses of PU-S-PEO were compared: 300 microns (thin) and 2000 microns (thick). Foreign body capsule (FBC) thickness was much less in PU-S-PEO implants than in PU implants. In addition, FBC were thinner in thin implants than in thick implants. FBC was much more dense in solid implants than in porous implants. As compared with solid implants, porous implants (PVA and ePTFE) led to a marked increase in the number of microvessels that developed adjacent to the implant, as observed both with hematoxylin/eosin staining and with an immunohistochemical anti-endothelial stain. We conclude that the polyethylene oxide and silicone moieties in PU reduce the thickness of the subsequent FBC. In addition, thin implants lead to a thin FBC. Porous implants (PVA and ePTFE) cause more angiogenesis than solid implants. These results may have implications for the measurement of blood-derived analytes by biosensors.
GAS/LIQUID MEMBRANES FOR NATURAL GAS UPGRADING
DOE Office of Scientific and Technical Information (OSTI.GOV)
Howard S. Meyer
Gas Technology Institute (GTI) is conducting this research program whose objective is to develop gas/liquid membranes for natural gas upgrading to assist DOE in achieving their goal of developing novel methods of upgrading low quality natural gas to meet pipeline specifications. Kvaerner Process Systems (KPS) and W. L. Gore & Associates (GORE) gas/liquid membrane contactors are based on expanded polytetrafluoroethylene (ePTFE) membranes acting as the contacting barrier between the contaminated gas stream and the absorbing liquid. These resilient membranes provide much greater surface area for transfer than other tower internals, with packing densities five to ten times greater, resulting inmore » equipment 50-70% smaller and lower weight for the same treating service. The scope of the research program is to (1) build and install a laboratory- and a field-scale gas/liquid membrane absorber; (2) operate the units with a low quality natural gas feed stream for sufficient time to verify the simulation model of the contactors and to project membrane life in this severe service; and (3) conducted an economic evaluation, based on the data, to quantify the impact of the technology. Chevron, one of the major producers of natural gas, has offered to host the test at a gas treating plant. KPS will use their position as a recognized leader in the construction of commercial amine plants for building the unit along with GORE providing the membranes. GTI will provide operator and data collection support during lab- and field-testing to assure proper analytical procedures are used. KPS and GTI will perform the final economic evaluation. GTI will provide project management and be responsible for reporting and interactions with DOE on this project. Efforts this quarter have concentrated on legal agreements, including alternative field sites. Preliminary design of the bench-scale equipment continues.« less
GAS/LIQUID MEMBRANES FOR NATURAL GAS UPGRADING
DOE Office of Scientific and Technical Information (OSTI.GOV)
Howard S. Meyer
Gas Technology Institute (GTI) is conducting this research program whose objective is to develop gas/liquid membranes for natural gas upgrading to assist DOE in achieving their goal of developing novel methods of upgrading low quality natural gas to meet pipeline specifications. Kvaerner Process Systems (KPS) and W. L. Gore & Associates (GORE) gas/liquid membrane contactors are based on expanded polytetrafluoroethylene (ePTFE) membranes acting as the contacting barrier between the contaminated gas stream and the absorbing liquid. These resilient membranes provide much greater surface area for transfer than other tower internals, with packing densities five to ten times greater, resulting inmore » equipment 50-70% smaller and lower weight for the same treating service. The scope of the research program is to (1) build and install a laboratory- and a field-scale gas/liquid membrane absorber; (2) operate the units with a low quality natural gas feed stream for sufficient time to verify the simulation model of the contactors and to project membrane life in this severe service; and (3) conducted an economic evaluation, based on the data, to quantify the impact of the technology. Chevron, one of the major producers of natural gas, has offered to host the test at a gas treating plant. KPS will use their position as a recognized leader in the construction of commercial amine plants for building the unit along with GORE providing the membranes. GTI will provide operator and data collection support during lab- and field-testing to assure proper analytical procedures are used. Kvaerner and GTI will perform the final economic evaluation. GTI will provide project management and be responsible for reporting and interactions with DOE on this project. Efforts this quarter have concentrated on legal agreements, including alternative field sites. Preliminary design of the bench-scale equipment continues.« less
GAS/LIQUID MEMBRANES FOR NATURAL GAS UPGRADING
DOE Office of Scientific and Technical Information (OSTI.GOV)
Howard S. Meyer
Efforts this quarter have concentrated on legal agreements, including alternative field sites. Preliminary design of the bench-scale equipment continues. Gas Technology Institute (GTI) is conducting this research program whose objective is to develop gas/liquid membranes for natural gas upgrading to assist DOE in achieving their goal of developing novel methods of upgrading low quality natural gas to meet pipeline specifications. Kvaerner Process Systems (KPS) and W. L. Gore & Associates (GORE) gas/liquid membrane contactors are based on expanded polytetrafluoroethylene (ePTFE) membranes acting as the contacting barrier between the contaminated gas stream and the absorbing liquid. These resilient membranes provide muchmore » greater surface area for transfer than other tower internals, with packing densities five to ten times greater, resulting in equipment 50--70% smaller and lower weight for the same treating service. The scope of the research program is to (1) build and install a laboratory- and a field-scale gas/liquid membrane absorber; (2) operate the units with a low quality natural gas feed stream for sufficient time to verify the simulation model of the contactors and to project membrane life in this severe service; and (3) conducted an economic evaluation, based on the data, to quantify the impact of the technology. Chevron, one of the major producers of natural gas, has offered to host the test at a gas treating plant. KPS will use their position as a recognized leader in the construction of commercial amine plants for building the unit along with GORE providing the membranes. GTI will provide operator and data collection support during lab- and field-testing to assure proper analytical procedures are used. Kvaerner and GTI will perform the final economic evaluation. GTI will provide project management and be responsible for reporting and interactions with DOE on this project.« less
The effect of interstitial air on the in vitro thrombogenicity of ePTFE vascular grafts
NASA Technical Reports Server (NTRS)
Rashid, S. N.; Clark, H. G.; Vann, R. D.; Gerth, W. A.; Palmos, L. A.; Mikat, E. M.
1992-01-01
Gas trapped in the interstices of the biomaterials used for vascular prostheses causes thrombosis, and the process of eliminating this gas is known as denucleation. An apparatus was developed for testing in the in vitro effects of denucleation on 4 mm I.D. expanded polytetrafluoroethylene (ePTFE) Vitagraft (Johnson and Johnson). The apparatus was designed to ensure that neither the blood nor the grafts came in contact with air. Blood from a single donor was incubated with control and denucleated grafts for 5, 10, 15, 20, and 30 minutes. The thrombus volume in the graft lumen was measured with a computer assisted videometric system. Little thrombus formed by 5 or 10 minutes, but there was less thrombus in the denucleated graft than in the control graft at all times. The differences were statistically significant at 15 and 20 minutes (p < 0.05). Denucleation nearly doubled the thrombus formation time. Thrombus was more adherent to denucleated grafts than to control grafts. These results are consistent with in vivo observations in the rat where denucleation decreased thrombus formation and increased patency duration.
GAS/LIQUID MEMBRANES FOR NATURAL GAS UPGRADING
DOE Office of Scientific and Technical Information (OSTI.GOV)
Howard S. Meyer
Efforts this quarter have concentrated on legal agreements, including alternative field sites. Preliminary design of the bench-scale equipment has been initiated. Gas Technology Institute (GTI) is conducting this research program whose objective is to develop gas/liquid membranes for natural gas upgrading to assist DOE in achieving their goal of developing novel methods of upgrading low quality natural gas to meet pipeline specifications. Kvaerner Process Systems (KPS) and W. L. Gore & Associates (GORE) gas/liquid membrane contactors are based on expanded polytetrafluoroethylene (ePTFE) membranes acting as the contacting barrier between the contaminated gas stream and the absorbing liquid. These resilient membranesmore » provide much greater surface area for transfer than other tower internals, with packing densities five to ten times greater, resulting in equipment 50--70% smaller and lower weight for the same treating service. The scope of the research program is to (1) build and install a laboratory- and a field-scale gas/liquid membrane absorber; (2) operate the units with a low quality natural gas feed stream for sufficient time to verify the simulation model of the contactors and to project membrane life in this severe service; and (3) conducted an economic evaluation, based on the data, to quantify the impact of the technology. Chevron, one of the major producers of natural gas, has offered to host the test at a gas treating plant. KPS will use their position as a recognized leader in the construction of commercial amine plants for building the unit along with GORE providing the membranes. GTI will provide operator and data collection support during lab- and field-testing to assure proper analytical procedures are used. Kvaerner and GTI will perform the final economic evaluation. GTI will provide project management and be responsible for reporting and interactions with DOE on this project.« less
Ito, Kiyoshi; Aoyama, Tatsuro; Horiuchi, Tetsuyoshi; Hongo, Kazuhiro
2015-12-01
The nonpenetrating titanium clip has been successfully used in peripheral arterial bypass surgery. The purpose of this study was to evaluate the leakage pressures and patterns of nonpenetrating titanium clips using a simple model that mimicked spinal surgery. In addition, the authors describe their surgical experience with these clips and the follow-up results in 31 consecutive patients. The authors compared nonpenetrating titanium clips and expanded polytetrafluoroethylene (ePTFE) sutures in relation to the water pressure that could be tolerated by sutured ePTFE sheets, and the leakage pressure patterns were determined. The changes in leakage pressures at 5 minutes, 30 minutes, and 12 hours were examined when the clips and sutures were used in combination with the mesh-and-glue technique in an in vitro study. Thirty-one patients underwent spinal intradural procedures using nonpenetrating titanium clips to suture the dura maters using the meshand-glue technique, involving fibrin glue and polyglycolic acid-fibrin sheets. A significant difference was apparent between the ePTFE suture group and the nonpenetrating titanium clip group, with the latter showing a leakage pressure that could be sustained and was 1508% higher than that of the former (p = 0.001). In relation to leakage patterns, the nonpenetrating titanium clips did not make any suture holes in the ePTFE sheet and fluid leakage occurred between the clips, whereas fluid leakage was associated with the pressure elevation that occurred at the suture holes made by the ePTFE sutures. Of the 31 patients who underwent spinal intradural procedures using nonpenetrating titanium clips, 1 (3.2%) experienced cerebrospinal fluid (CSF) leakage postoperatively. No other complications-for example, allergic reactions, adhesions, or infections--were encountered. The interrupted placement of nonpenetrating titanium clips enables dural closure without creating any holes. These clips facilitate improvements in the initial leakage pressure and reduce postoperative CSF leakage following spinal surgery. The authors conclude that it is very beneficial to suture the spinal dura mater using nonpenetrating titanium clips given the anatomical characteristics of the spinal dura mater and the fact that the clips do not create suture holes.
Rowe, D J; Ko, S; Tom, X M; Silverstein, S J; Richards, D W
1999-09-01
Vitamin C or ascorbate is important in wound healing due to its essential role in collagen synthesis. To study wound healing in the periodontium, cells adherent to expanded polytetrafluoroethylene (ePTFE) augmentation membranes, recovered from edentulous ridge augmentation procedures, have been established in culture in our laboratories. The objective of this study was to determine whether treatment of these cells with a calcium ascorbate, which contains vitamin C metabolites (metabolite-supplemented ascorbate), would increase the production of collagenous protein and mineralized tissue in vitro, as compared to unsupplemented calcium ascorbate (ascorbate). Cells derived from ePTFE membranes were cultured with beta-glycerophosphate and the test agents for 2 to 5 weeks, and the surface areas of the cell cultures occupied by mineralized nodules were measured using computerized image analysis. One experiment tested the effects of calcium threonate, one of the vitamin C metabolites in metabolite-supplemented ascorbate. Incorporation of radioactive proline and glycine was used as a measure of total protein (radioactivity precipitated by trichloracetic acid) and collagenase-digestible protein (radioactivity released by collagenase digestion.) Co-localization of collagen and fibronectin was examined by immunofluorescence. In vitro treatment of these cells with metabolite-supplemented ascorbate increased the area of the cell cultures occupied by mineralized nodules after 5 weeks. Cell cultures treated with metabolite-supplemented ascorbate also exhibited significant increases in total protein. The increase in collagenous proteins in these cultures accounted for 85% of the increase in total protein. The greatest difference between treatment groups was observed in the cell-associated fraction containing the extracellular matrix. The additional collagen exhibited normal co-distribution with fibronectin. In cultures treated with ascorbate spiked with calcium threonate, the area of mineralized tissue was significantly greater than in ascorbate-treated cultures, but was less than that observed in cultures treated with metabolite-supplemented ascorbate. In vitro treatment with ascorbate containing vitamin C metabolites enhanced the formation of mineralized nodules and collagenous proteins. Calcium threonate may be one of the metabolites influencing the mineralization process. Identifying factors which facilitate the formation of mineralized tissue has significant clinical ramifications in terms of wound healing and bone regeneration.
Li, Chaojing; Wang, Fujun; Douglas, Graeham; Zhang, Ze; Guidoin, Robert; Wang, Lu
2017-05-01
Vascular grafts made by tissue engineering processes are prone to buckling and twisting, which can impede blood flow and lead to collapse of the vessel. These vascular conduits may suffer not only from insufficient tensile strength, but also from vulnerabilities related to compression, torsion, and pulsatile pressurization. Aiming to develop a tissue engineering-inspired blood conduit, composite vascular graft (cVG) prototypes were created by combining a flexible polylactic acid (PLA) knitted fabric with a soft polycaprolactone (PCL) matrix. The graft is to be populated in-situ with cellular migration and proliferation into the device. Comprehensive characterizations probed the relationship between structure and mechanical properties of the different cVG prototypes. The composite grafts exhibited major improvements in mechanical characteristics compared to single-material devices, with particular improvement in compression and torsional resistance. A commercial expanded polytetrafluoroethylene (ePTFE) vascular graft was used as a control against the proposed composite vascular grafts. CVG devices showed high tensile strength, high bursting strength, and improved suture retention. Compression, elastic recovery, and compliance were similar to those for the ePTFE graft. Copyright © 2016 Elsevier Ltd. All rights reserved.
GAS/LIQUID MEMBRANES FOR NATURAL GAS UPGRADING
DOE Office of Scientific and Technical Information (OSTI.GOV)
Howard S. Meyer
A new project was initiated this quarter to develop gas/liquid membranes for natural gas upgrading. Efforts have concentrated on legal agreements, including alternative field sites. Gas Technology Institute (GTI) is conducting this research program whose objective is to develop gas/liquid membranes for natural gas upgrading to assist DOE in achieving their goal of developing novel methods of upgrading low quality natural gas to meet pipeline specifications. Kvaerner Process Systems (KPS) and W. L. Gore & Associates (GORE) gas/liquid membrane contactors are based on expanded polytetrafluoroethylene (ePTFE) membranes acting as the contacting barrier between the contaminated gas stream and the absorbingmore » liquid. These resilient membranes provide much greater surface area for transfer than other tower internals, with packing densities five to ten times greater, resulting in equipment 50-70% smaller and lower weight for the same treating service. The scope of the research program is to (1) build and install a laboratory- and a field-scale gas/liquid membrane absorber; (2) operate the units with a low quality natural gas feed stream for sufficient time to verify the simulation model of the contactors and to project membrane life in this severe service; and (3) conducted an economic evaluation, based on the data, to quantify the impact of the technology. Chevron, one of the major producers of natural gas, has offered to host the test at a gas treating plant. KPS will use their position as a recognized leader in the construction of commercial amine plants for building the unit along with GORE providing the membranes. GTI will provide operator and data collection support during lab- and field-testing to assure proper analytical procedures are used. Kvaerner and GTI will perform the final economic evaluation. GTI will provide project management and be responsible for reporting and interactions with DOE on this project.« less
GAS/LIQUID MEMBRANES FOR NATURAL GAS UPGRADING
DOE Office of Scientific and Technical Information (OSTI.GOV)
Howard S. Meyer
Gas Technology Institute (GTI) is conducting this research program whose objective is to develop gas/liquid membranes for natural gas upgrading to assist DOE in achieving their goal of developing novel methods of upgrading low quality natural gas to meet pipeline specifications. Kvaerner Process Systems (KPS) and W. L. Gore & Associates (GORE) gas/liquid membrane contactors are based on expanded polytetrafluoroethylene (ePTFE) membranes acting as the contacting barrier between the contaminated gas stream and the absorbing liquid. These resilient membranes provide much greater surface area for transfer than other tower internals, with packing densities five to ten times greater, resulting inmore » equipment 50-70% smaller and lower weight for the same treating service. The scope of the research program is to (1) build and install a laboratory- and a field-scale gas/liquid membrane absorber; (2) operate the units with a low quality natural gas feed stream for sufficient time to verify the simulation model of the contactors and to project membrane life in this severe service; and (3) conducted an economic evaluation, based on the data, to quantify the impact of the technology. Chevron, one of the major producers of natural gas, has offered to host the test at a gas treating plant. KPS will use their position as a recognized leader in the construction of commercial amine plants for building the unit along with GORE providing the membranes. GTI will provide operator and data collection support during lab- and field-testing to assure proper analytical procedures are used. KPS and GTI will perform the final economic evaluation. GTI will provide project management and be responsible for reporting and interactions with DOE on this project. Efforts this quarter have concentrated on field site selection. ChevronTexaco has nominated their Headlee Gas Plant in Odessa, TX for a commercial-scale dehydration test. Potting and module materials testing were initiated. Preliminary design of the bench-scale equipment continues.« less
GAS/LIQUID MEMBRANES FOR NATURAL GAS UPGRADING
DOE Office of Scientific and Technical Information (OSTI.GOV)
Howard S. Meyer
Gas Technology Institute (GTI) is conducting this research program whose objective is to develop gas/liquid membranes for natural gas upgrading to assist DOE in achieving their goal of developing novel methods of upgrading low quality natural gas to meet pipeline specifications. Kvaerner Process Systems (KPS) and W. L. Gore & Associates (GORE) gas/liquid membrane contactors are based on expanded polytetrafluoroethylene (ePTFE) membranes acting as the contacting barrier between the contaminated gas stream and the absorbing liquid. These resilient membranes provide much greater surface area for transfer than other tower internals, with packing densities five to ten times greater, resulting inmore » equipment 50-70% smaller and lower weight for the same treating service. The scope of the research program is to (1) build and install a laboratory- and a field-scale gas/liquid membrane absorber; (2) operate the units with a low quality natural gas feed stream for sufficient time to verify the simulation model of the contactors and to project membrane life in this severe service; and (3) conducted an economic evaluation, based on the data, to quantify the impact of the technology. Chevron, one of the major producers of natural gas, has offered to host the test at a gas treating plant. KPS will use their position as a recognized leader in the construction of commercial amine plants for building the unit along with GORE providing the membranes. GTI will provide operator and data collection support during lab- and field-testing to assure proper analytical procedures are used. Kvaerner and GTI will perform the final economic evaluation. GTI will provide project management and be responsible for reporting and interactions with DOE on this project. Efforts this quarter have concentrated on field site selection. ChevronTexaco has nominated their Headlee Gas Plant in Odessa, TX for a commercial-scale dehydration test. Design and cost estimation for this new site are underway. Potting and module materials testing continued. Preliminary design of the bench-scale equipment continues.« less
Computed tomographic assessment of the causal factors of unsuccessful medialization thyroplasty.
Iwahashi, Toshihiko; Ogawa, Makoto; Hosokawa, Kiyohito; Mochizuki, Ryuichi; Inohara, Hidenori
2015-03-01
The present results demonstrate that a small implant size, undercorrection of the vocal fold, antero-posterior implant malposition, and the use of expanded polytetrafluoroethylene (ePTFE) are the primary factors that cause a poor outcome of medialization thyroplasty (MT). To assess the postoperative laryngeal condition using computed tomography (CT) in patients with unilateral vocal fold paralysis who underwent MT alone, and to identify the primary causal factors in terms of the surgical procedures that affect the outcomes of MT. Twenty-two patients who underwent MT alone were divided into two groups based on either the maximal phonation time or the perceived vocal breathiness. Two laryngologists assessed the postoperative laryngeal CT images during sustained vowel phonation and judged whether there were abnormalities of the arytenoid cartilage position, window position, implant size, and implant position, as well as the degree of correction of the vocal fold. As implant material, a silicone block, ePTFE, and hydroxyapatite had been inserted in 2, 9, and 11 patients, respectively. Comparisons of the prevalence of abnormalities in the abovementioned factors between the different outcomes and between the types of material used for the implant were performed. Twelve patients with a poor outcome and 10 with a good outcome showed 36 and 18 abnormal findings identified by either of the two laryngologists, respectively. In the poor outcome group, a smaller implant size and undercorrection of the vocal fold showed both high kappa values and a significantly higher prevalence than those in the good outcome group (p < 0.001 and p < 0.05), respectively. The comparison between material types demonstrated that the sheet-like material (ePTFE) group exhibited a significantly higher prevalence of undercorrection than the block-like material group (p < 0.05).
NASA Astrophysics Data System (ADS)
Norowski, Peter Andrew, Jr.
Guided tissue regeneration (GTR) is a surgical technique commonly used to exclude bacteria and soft tissues from bone graft sites in oral/maxillofacial bone graft sites by using a barrier membrane to maintain the graft contour and space. Current clinical barrier membrane materials based on expanded polytetrafluoroethylene (ePTFE) and bovine type 1 collagen are non-ideal and experience a number of disadvantages including membrane exposure, bacterial colonization/biofilm formation and premature degradation, all of which result in increased surgical intervention and poor bone regeneration. These materials do not actively participate in tissue regeneration, however bioactive materials, such as chitosan, may provide advantages such as the ability to stimulate wound healing and de novo bone formation. Our hypothesis is that electrospun chitosan GTR membranes will support cell attachment and growth but prevent cell infiltration/penetration of membrane, demonstrate in vitro degradation predictive of 4--6 month in vivo functionality, and will deliver antibiotics locally to prevent/inhibit periopathogenic complications. To test this hypothesis a series of chitosan membranes were electrospun, in the presence or absence of genipin, a natural crosslinking agent, at concentrations of 5 and 10 mM. These membranes were characterized by scanning electron microscopy, tensile testing, suture pullout testing, Fourier transform infrared spectroscopy, X-ray diffraction, and gel permeation chromatography, and in vitro biodegradation for diameter/morphology of fibers, membrane strengths, degree of crosslinking, crystallinity, molecular weight, and degradation kinetics, respectively. Cytocompability of membranes was evaluated in osteoblastic, fibroblastic and monocyte cultures. The activity of minocycline loaded and released from the membranes was determined in zone of inhibition tests using P. gingivalis microbe. The results demonstrated that genipin crosslinking extended the in vitro degradation timeframe, extended the release of minocycline, and increased the tensile strength of the resultant membranes while cytocompatibility, swelling, and tear strength were unaffected. In conclusion, electrospun chitosan membranes crosslinked with genipin are a suitable material for guided tissue regeneration and may help reduce bacterial infection and bacteria-induced host inflammatory response.
Rim, Yonghoon; Laing, Susan T.; McPherson, David D.; Kim, Hyunggun
2013-01-01
Mitral valve repair using expanded polytetrafluoroethylene (ePTFE) sutures is an established and preferred interventional method to resolve the complex pathophysiologic problems associated with chordal rupture. We developed a novel computational evaluation protocol to determine the effect of the artificial sutures on restoring mitral valve function following valve repair. A virtual mitral valve was created using three-dimensional echocardiographic data in a patient with ruptured mitral chordae tendineae. Virtual repairs were designed by adding artificial sutures between the papillary muscles and the posterior leaflet where the native chordae were ruptured. Dynamic finite element simulations were performed to evaluate pre- and post-repair mitral valve function. Abnormal posterior leaflet prolapse and mitral regurgitation was clearly demonstrated in the mitral valve with ruptured chordae. Following virtual repair to reconstruct ruptured chordae, the severity of the posterior leaflet prolapse decreased and stress concentration was markedly reduced both in the leaflet tissue and the intact native chordae. Complete leaflet coaptation was restored when four or six sutures were utilized. Computational simulations provided quantitative information of functional improvement following mitral valve repair. This novel simulation strategy may provide a powerful tool for evaluation and prediction of interventional treatment for ruptured mitral chordae tendineae. PMID:24072489
Barboza, Eliane Porto; Stutz, Bianca; Ferreira, Vinícius Farias; Carvalho, Waldimir
2010-02-01
The biologic principle of guided bone regeneration has been successfully used to prevent bone loss in extraction sites. This study comprises 420 cases of alveolar ridge maintenance in preparation for dental implant placements. Nonexpanded polytetrafluoroethylene membranes were positioned over all extraction sites and left intentionally exposed. Lyophilized mineralized bone allografts were used to prevent membrane collapse when buccal bone walls were lost. Membranes were removed at week 4. At the time of implant placements, all sites presented soft tissue compatibility with keratinized gingiva. The mucogingival junction position seemed to be preserved. Exposed nonexpanded polytetrafluoroethylene membranes associated, or not, with bone graft provide tissue formation suitable for implant placement.
Tabata, R; Kobayashi, T; Mori, A; Matsuno, S; Watarida, S; Onoe, M; Sugita, T; Shiraisi, S; Nojima, T
1993-04-01
We explored the blood-retaining mechanism of a vascular prosthesis made of expanded polytetrafluoroethylene through analysis of its structure and physicochemical properties. Plasma leakage through this vascular prosthesis was simulated by computer to explore its etiology. These examinations disclosed that leakage is dependent upon the inner pressure and the density of fibers. In other words, the study revealed that the mean distance between fibers constituting the wall of the expanded polytetrafluoroethylene vascular prosthesis is increased by tension (that is, inner pressure), resulting in an increased probability of leakage. It was additionally found that a thin membrane is formed on the polytetrafluoroethylene surface if blood in contact with the surface is dried. This membrane was found to reduce the water-repelling property of polytetrafluoroethylene and to make it impossible to preserve the inter-fiber liquid surface, thus causing leakage through the expanded polytetrafluoroethylene vascular prosthesis.
GAS/LIQUID MEMBRANES FOR NATURAL GAS UPGRADING
DOE Office of Scientific and Technical Information (OSTI.GOV)
Howard S. Meyer
Gas Technology Institute (GTI) is conducting this research program whose objective is to develop gas/liquid membranes for natural gas upgrading to assist DOE in achieving their goal of developing novel methods of upgrading low quality natural gas to meet pipeline specifications. Kvaerner Process Systems (KPS) and W. L. Gore & Associates (GORE) gas/liquid membrane contactors are based on expanded polytetrafluoroethylene (ePTFE) membranes acting as the contacting barrier between the contaminated gas stream and the absorbing liquid. These resilient membranes provide much greater surface area for transfer than other tower internals, with packing densities five to ten times greater, resulting inmore » equipment 50-70% smaller and lower weight for the same treating service. The scope of the research program is to (1) build and install a laboratory- and a field-scale gas/liquid membrane absorber; (2) operate the units with a low quality natural gas feed stream for sufficient time to verify the simulation model of the contactors and to project membrane life in this severe service; and (3) conducted an economic evaluation, based on the data, to quantify the impact of the technology. Chevron, one of the major producers of natural gas, has offered to host the test at a gas treating plant. KPS will use their position as a recognized leader in the construction of commercial amine plants for building the unit along with GORE providing the membranes. GTI will provide operator and data collection support during lab- and field-testing to assure proper analytical procedures are used. Kvaerner and GTI will perform the final economic evaluation. GTI will provide project management and be responsible for reporting and interactions with DOE on this project. Efforts this quarter have concentrated on field site selection. ChevronTexaco has nominated their Headlee Gas Plant in Odessa, TX for a commercial-scale dehydration test. Design and cost estimation for this new site are underway. A HazOp review was conducted. Potting and module materials testing continued. Preliminary design of the bench-scale equipment continues. A status meeting was held in Morgantown, WV with the DOE Project Manager.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Vrana, D.L.; Meagher, M.M.; Hutkins, R.W.
1993-10-01
A pervaporation apparatus was designed and tested in an effort to develop an integrated fermentation and product recovery process for acetone-butanol-ethanol(ABE) fermentation. A crossflow membrane module able to accommodate flat sheet hydrophobic membranes was used for the experiments. Permeate vapors were collected under vacuum and condensed in a dry ice/ethanol cold trap. The apparatus containing polytetrafluoroethylene membranes was tested using butanol-water and model solutions of ABE products. Parameters such as product concentration, component effect, temperature, and permeate side pressure were examined. 25 refs., 3 figs., 5 tabs.
NASA Astrophysics Data System (ADS)
Shi, Zhiquan; Zhou, Hui; Qing, Xutang; Dai, Tingyang; Lu, Yun
2012-06-01
Porous poly(tetrafluoroethylene) (PTFE) membranes play an important role in air purification and separation engineering. To achieve the bi-functionality of conducting and antibacterial property, two kinds of poly(tetrafluoroethylene)@ polypyrrole/nano-silver composite membranes have been prepared. One involves hydrophobic polypyrrole/nano-silver composite with hollow capsule nanostructures immobilized on the surface of the PTFE membranes. The other is a type of composite membranes with polypyrrole/nano-silver composite wholly packed on the fibrils of the expand PTFE membrane to form core/shell coaxial cable structures. The structure and morphology of the two kinds of composite membranes have been characterized by FTIR, UV-vis, XRD, TGA and SEM measurements. Possible formation mechanisms of the hollow capsules and the core/shell nanocable structures have been discussed in detail. The antibacterial effects of composite membranes are also briefly investigated.
Kidd, Kameha R; Dal Ponte, Donny B; Kellar, Robert S; Williams, Stuart K
2002-03-15
End product application is an important consideration when evaluating a material in an in vivo setting (Didisheim, Cardiovasc Pathol 1993;2:1S-2S). Small animal models allow high through-put evaluation of biocompatability. Previous preclinical evaluations have often used a rat subcutaneous model for the characterization of material-tissue interaction. Recent advances in genetic manipulation have provided mouse models with selective expression of a wide range of critical proteins. The rat model does not have many of the resources (i.e., knockouts, SCID, nude) that are present in mouse strains. The availability of these mice provides a resource to delineate the mechanisms regulating the healing associated with implants. However, before the mouse models can be used, they must be validated with respect to their ability to accurately assess tissue responses to materials. In this study the tissue responses after the implantation of expanded polytetrafluoroethylene (ePTFE) were compared between rat and mouse. Discs of ePTFE (30-microm internodal distance) were implanted in subcutaneous and epididymal fat tissue of rats (Sprague-Dawley) and mice (129-SVJ). After 5 weeks the samples were removed and evaluated for vascular density, inflammation, and fibrous encapsulation. No difference in the vessel density was observed within the peri-implant subcutaneous and adipose tissue or within the porous material. However, a significant difference was found in the number of activated macrophages and giant cells between these two species. Implants in the rat exhibited greater numbers of activated inflammatory cells in the peri-implant tissue. The data indicate that the mouse and rat provide a comparable model for evaluating angiogenesis and neovascularization associated with synthetic porous implants. Copyright 2001 John Wiley & Sons, Inc. J Biomed Mater Res 59: 682-689, 2002
Jet blown PTFE for control of biocompatibility
NASA Astrophysics Data System (ADS)
Leibner, Evan Scott
The development of fully hemocompatible cardiovascular biomaterials will have a major impact on the practice of modern medicine. Current artificial surfaces, unlike native vascular surfaces, are not able to control clot and thrombus formation. Protein interactions are an important component in hemocompatibility and can result in decreased patency due to thrombus formation or surface passivation which can improve endothelization. It is believed that controlling these properties, specifically the nanometer sizes of the fibers on the material's surface, will allow for better control of biological responses. The biocompatibility of Teflon, a widely used polymer for vascular grafts, would be improved with nanostructured control of surface features. Due to the difficultly in processing polytetrafluoroethylene (PTFE), it has not been possible to create nanofibrous PTFE surfaces. The novel technique of Jet Blowing allows for the formation of nanostructured PTFE (nPTFE). A systematic investigation into controlling polymer properties by varying the processing conditions of temperature, pressure, and gas used in the Jet Blowing allows for an increased understanding of the effects of plasticization on the material's properties. This fundamental understanding of the material science behind the Jet Blowing process has enabled control of the micro and nanoscale structure of nPTFE. While protein adsorption, a key component of biocompatibility, has been widely studied, it is not fully understood. Major problems in the field of biomaterials include a lack of standard protocols to measure biocompatibility, and inconstant literature on protein adsorption. A reproducible protocol for measuring protein adsorption onto superhydrophobic surfaces (ePTFE and nPTFE) has been developed. Both degassing of PBS buffer solutions and evacuation of the air around the expanded PTFE (ePTFE) prior to contact with protein solutions are essential. Protein adsorption experiments show a four-fold difference in the measure of proteins adsorbed using radiometry (I-125 labeled human serum albumin (HSA)) and electrophoresis (unlabeled HSA). This provides evidence that the standard method of radiolabeled protein for measuring adsorption does not fully account for changes to the HSA molecules due to labeling. The differences between measured protein values can be attributed to the radiolabel affecting the HSA hydrophobicity resulting in a change in the protein's interactions with the hydrophobic surface. Additionally, our work has provided repeatable results showing that the amount of protein adsorbed onto the polymer surface, after washing, accounted for only 65% of the amount of protein that was removed from solution based on depletion analysis. This implies that measurement of the amount of strongly bound protein on the material significantly underestimates the actual amount of protein adsorbing into the surface region of the material interface. HSA adsorption isotherms demonstrate an increase in protein adsorption capacity on the nPTFE surface compared to adsorption on the same surface area of ePTFE. Preliminary cell work shows that the nPTFE surfaces had a larger number of cells growing on the surface of the material when compared to ePTFE surfaces. The research also shows that while most endothelial cells were not viable on the ePTFE surface after 96 hours, they remained alive on the nPTFE surface during that same time period. Surface functionalization using ammonia plasma has been performed. X-ray photoelectron spectroscopy (XPS) analysis revealed the presence of amine groups on the nPTFE surface. The amine groups can be used to couple polypeptides onto the PTFE surface in the future. The selection of different peptides will allow for selective control of cell adhesion. This research shows that nPTFE has potential for improved biocompatibility over standard ePTFE, based on increased protein adsorption capacity, increased viability of endothelial cells, and the ability to plasma modify the PTFE surface.
Continuum modeling of charging process and piezoelectricity of ferroelectrets
NASA Astrophysics Data System (ADS)
Xu, Bai-Xiang; von Seggern, Heinz; Zhukov, Sergey; Gross, Dietmar
2013-09-01
Ferroelectrets in the form of electrically charged micro-porous foams exhibit a very large longitudinal piezoelectric coefficient d33. The structure has hence received wide application interests as sensors particularly in acoustic devices. During charging process, electrical breakdown (Paschen breakdown) takes place in the air pores of the foam and introduces free charge pairs. These charges are separated by electrostatic forces and relocated at the interfaces between the polymer and the electrically broken-down medium, where they are trapped quasistatically. The development of this trapped charge density along the interfaces is key for enabling the piezoelectricity of ferroelectrets. In this article, an internal variable based continuum model is proposed to calculate the charge density development at the interfaces, whereas a Maxwell stress based electromechanical model is used for the bulk behavior, i.e., of the polymer and of the medium where the Paschen breakdown takes place. In the modeling, the electrostatic forces between the separated charge pairs are included, as well as the influence of deformation of the solid layers. The material models are implemented in a nonlinear finite element scheme, which allows a detailed analysis of different geometries. A ferroelectret unit with porous expanded polytetrafluoroethylene (ePTFE) surrounded by fluorinated ethylene propylene is studied first. The simulated hysteresis curves of charge density at the surfaces and the calculated longitudinal piezoelectric constant are in good agreement with experimental results. Simulations show a strong dependency of the interface charge development and thus the remnant charges on the thicknesses of the layers and the permittivity of the materials. According to the calculated relation between d33 and the Young's modulus of ePTFE, the value of the Young's modulus of ePTFE is identified to be around 0.75 MPa, which lies well in the predicted range of 0.45 to 0.80 MPa, determined from the dielectric resonance spectra in the work of Zhang et al. [X. Q. Zhang et al., J. Appl. Phys. 108, 064113 (2010)]. To show the potential of the models, it is also applied to simulation of ferroelectrets with a lens shape. The results indicate that the electrical breakdown happens in a sequential manner, and the local piezoelectric coefficient varies with position. Thereby, the middle point on the surface exhibits the maximum d33. The simulation results obtained by the proposed models will provide insight for device optimization.
Fuller, Timothy J.; Jiang, Ruichun
2017-01-24
A method for forming a modified solid polymer includes a step of contacting a solid fluorinated polymer with a sodium sodium-naphthalenide solution to form a treated fluorinated solid polymer. The treated fluorinated solid polymer is contacted with carbon dioxide, sulfur dioxide, or sulfur trioxide to form a solid grafted fluorinated polymer. Characteristically, the grafted fluorinated polymer includes appended CO.sub.2H or SO.sub.2H or SO.sub.3H groups. The solid grafted fluorinated polymer is advantageously incorporated into a fuel cell as part of the ion-conducting membrane or a water transport membrane in a humidifier.
Device-modified trabeculectomy for glaucoma
Wang, Xue; Khan, Rabeea; Coleman, Anne
2015-01-01
Background Glaucoma is an optic neuropathy that leads to vision loss and blindness. It is the second most common cause of irreversible blindness worldwide. The main treatment for glaucoma aims to reduce intraocular pressure (IOP) in order to slow or prevent further vision loss. IOP can be lowered with medications, and laser or incisional surgeries. Trabeculectomy is the most common incisional surgical procedure to treat glaucoma. Device-modified trabeculectomy is intended to improve drainage of the aqueous humor to lower IOP. Trabeculectomy-modifying devices include Ex-PRESS, Ologen, amniotic membrane, expanded polytetrafluoroethylene (E-PTFE) membrane, Gelfilm and others. However, the effectiveness and safety of these devices are uncertain. Objectives To assess the relative effectiveness, primarily with respect to IOP control and safety, of the use of different devices as adjuncts to trabeculectomy compared with standard trabeculectomy in eyes with glaucoma. Search methods We searched CENTRAL (which contains the Cochrane Eyes and Vision Trials Register) (2014, Issue 12), Ovid MEDLINE, Ovid MEDLINE In-Process and Other Non-Indexed Citations, Ovid MEDLINE Daily, Ovid OLDMEDLINE (January 1946 to December 2014), EMBASE (January 1980 to December 2014), PubMed (1948 to December 2014), Latin American and Caribbean Literature on Health Sciences (LILACS) (January 1982 to December 2014), the metaRegister of Controlled Trials (mRCT) (www.controlledtrials.com), ClinicalTrials.gov (www.clinicaltrials.gov), and the World Health Organization (WHO) International Clinical Trials Registry Platform (ICTRP) (www.who.int/ictrp/search/en). We did not use any date or language restrictions in the electronic search for trials. We last searched the electronic databases on 22 December 2014. Selection criteria We included randomized controlled trials comparing devices used during trabeculectomy with trabeculectomy alone. We also included studies where antimetabolites were used in either or both treatment groups. Data collection and analysis We used standard procedures expected by Cochrane. Main results We found 33 studies that met our inclusion criteria, of which 30 were published as full-length journal articles and three as conference abstracts. Only five studies have been registered. The 33 studies included a total of 1542 participants with glaucoma, and compared five types of devices implanted during trabeculectomy versus trabeculectomy alone. Five studies reported the use of Ex-PRESS (386 participants), eight studies reported the use of Ologen (327 participants), 18 studies reported the use of amniotic membrane (726 participants), one study reported the use of E-PTFE (60 participants), and one study reported the use of Gelfilm (43 participants). These studies were conducted in North America, South America, Europe, Asia, and the Middle East. Planned participant follow-up periods ranged from three months to five years. The studies were reported poorly which limited our ability to judge risk of bias for many domains. Only two studies explicitly masked outcome assessment so, we rated 31 studies at high risk of detection bias. Low-quality evidence from three studies showed that use of Ex-PRESS compared with trabeculectomy alone may be associated with a slightly lower IOP at one year (mean difference (MD) −1.58 mm Hg, 95% confidence interval (CI) −2.74 to −0.42; 165 eyes). Cataract surgery and hyphema may be less frequent in the Ex-PRESS group than in the trabeculectomy-alone group (cataract surgery: risk ratio (RR) 0.32, 95% CI 0.14 to 0.74, 3 studies, low-quality evidence; hyphema: RR 0.33, 95% CI 0.12 to 0.94, 4 studies, low-quality evidence). The effect of whether Ex-PRESS prevents hypotony was uncertain (RR 0.92, 95% CI 0.63 to 1.33, 2 studies, very low-quality evidence). All these studies received funding from the device manufacturer. Very low-quality evidence from five studies suggests that use of Ologen compared with trabeculectomy alone is associated with slightly higher IOP at one year (MD 1.40 mm Hg, 95% CI −0.57 to 3.38; 177 eyes). The effect of Ologen on preventing hypotony was uncertain (RR 0.75, 95% CI 0.47 to 1.19, 5 studies, very low-quality evidence). Differences between the two treatment groups for other reported complications also were inconclusive. Low-quality evidence from nine studies suggests that use of amniotic membrane with trabeculectomy may be associated with lower IOP at one year compared with trabeculectomy alone (MD −3.92 mm Hg, 95% CI −5.41 to −2.42; 356 eyes). Low-quality evidence showed that use of amniotic membrane may prevent adverse events and complications, such as hypotony (RR 0.40, 95% CI 0.17 to 0.94, 5 studies, low-quality evidence). The report from the only E-PTFE study (60 eyes) showed no important differences for postoperative IOP at one year (MD −0.44 mm Hg, 95% CI −1.76 to 0.88) between the trabeculectomy + E-PTFE versus the trabeculectomy-alone groups. Hypotony was the only postoperative complication observed less frequently in the E-PTFE group compared to the trabeculectomy-alone group (RR 0.29, 95% CI 0.11 to 0.77). The one Gelfilm study reported uncertainty in the difference in IOP and complication rates between the two groups at one year; no further data were provided in the study report. Authors’ conclusions Overall, the use of devices with standard trabeculectomy may help with greater IOP reduction at one-year follow-up than trabeculectomy alone; however, due to potential biases and imprecision in effect estimates, the quality of evidence is low. When we examined outcomes within subgroups based on the type of device used, our findings suggested that the use of an Ex-PRESS device or an amniotic membrane as an adjunct to trabeculectomy may be slightly more effective in reducing IOP at one year after surgery compared with trabeculectomy alone. The evidence that these devices are as safe as trabeculectomy alone is unclear. Due to various limitations in the design and conduct of the included studies, the applicability of this evidence synthesis to other populations or settings is uncertain. Further research is needed to determine the effectiveness and safety of other devices and in subgroup populations, such as people with different types of glaucoma, of various races and ethnicity, and with different lens types (e.g. phakic, pseudophakic). PMID:26625212
NASA Astrophysics Data System (ADS)
Yu, Hongyan; Shi, Jianheng; Zeng, Xinmiao; Bao, Mao; Zhao, Xinqing
2009-07-01
A polytetrafluoroethylene (PTFE) based organic-inorganic hybrid proton-exchange membrane was prepared from simultaneous radiation grafting of styrene (St) into porous PTFE membrane with the in situ sol-gel reaction of tetraethoxysilane (TEOS) followed by sulfonation in fuming sulfonic acid. The effect of radiation on the sol-gel reaction was studied. The results show that radiation promotes the sol-gel reaction with the help of St at room temperature. Incorporated silica gel helps to produce higher degree of grafting (DOG). SEM analysis was conducted to confirm that the inorganic silicon oxide was introduced to produce hybrid membrane in this work. The proton conductivity of membrane evaluated using electrochemical impedance spectroscopy is much higher (14.3×10 -2 S cm -1) than that of Nafion ® 117 at temperature of 80 °C with acceptable water uptake 51 wt%.
NASA Astrophysics Data System (ADS)
Qian, Yingjia; Chi, Lina; Zhou, Weili; Yu, Zhenjiang; Zhang, Zhongzhi; Zhang, Zhenjia; Jiang, Zheng
2016-01-01
Surface hydrophilic modification of polymer ultrafiltration membrane using metal oxide represents an effective yet highly challenging solution to improve water flux and antifouling performance. Via plasma-enhanced graft of poly acryl acid (PAA) prior to coating TiO2, we successfully fixed TiO2 functional thin layer on super hydrophobic polytetrafluoroethylene (PTFE) ultrafiltration (UF) membranes. The characterization results evidenced TiO2 attached on the PTFE-based UF membranes through the chelating bidentate coordination between surface-grafted carboxyl group and Ti4+. The TiO2 surface modification may greatly reduce the water contact angle from 115.8° of the PTFE membrane to 35.0° without degradation in 30-day continuous filtration operations. The novel TiO2/PAA/PTFE membranes also exhibited excellent antifouling and self-cleaning performance due to the intrinsic hydrophilicity and photocatalysis properties of TiO2, which was further confirmed by the photo-degradation of MB under Xe lamp irradiation.
Study on surface adhesion of Plasma modified Polytetrafluoroethylene hollow fiber membrane
NASA Astrophysics Data System (ADS)
Chen, Jiangrong; Zhang, Huifeng; Liu, Guochang; Guo, Chungang; Lv, Jinglie; Zhangb, Yushan
2018-01-01
Polytetrafluoroethylene (PTFE) is popular membrane material because of its excellent thermal stability, chemical stability and mechanical stability. However, the low surface energy and non-sticky property of PTFE present challenges for modification. In the present study, plasma treatment was performed to improve the surface adhesion of PTFE hollow fiber membrane. The effect of discharge voltage, treatment time on the adhesion of PTFE hollow fiber membrane was symmetrically evaluated. Results showed that the plasma treatment method contributed to improve the surface activity and roughness of PTFE hollow fiber membrane, and the adhesion strength depend significantly on discharge voltage, which was beneficial to seepage pressure of PTFE hollow fiber membrane module. The adhesion strength of PTFE membrane by plasma treated at 220V for 3min reached as high as 86.2 N, far surpassing the adhesion strength 12.7 N of pristine membrane. Furthermore, improvement of content of free radical and composition analysis changes of the plasma modified PTFE membrane were investigated. The seepage pressure of PTFE membrane by plasma treated at 220V for 3min was 0.375 MPa, which means that the plasma treatment is an effective technique to improve the adhesion strength of membrane.
Koens, M J W; Krasznai, A G; Hanssen, A E J; Hendriks, T; Praster, R; Daamen, W F; van der Vliet, J A; van Kuppevelt, T H
2015-01-01
abstract A persistent clinical demand exists for a suitable arterial prosthesis. In this study, a vascular conduit mimicking the native 3-layered artery, and constructed from the extracellular matrix proteins type I collagen and elastin, was evaluated for its performance as a blood vessel equivalent. A tubular 3-layered graft (elastin-collagen-collagen) was prepared using highly purified type I collagen fibrils and elastin fibers, resembling the 3-layered native blood vessel architecture. The vascular graft was crosslinked and heparinised (37 ± 4 μg heparin/mg graft), and evaluated as a vascular graft using a porcine bilateral iliac artery model. An intra-animal comparison with clinically-used heparinised ePTFE (Propaten®) was made. Analyses included biochemical characterization, duplex scanning, (immuno)histochemistry and scanning electron microscopy. The tubular graft was easy to handle with adequate suturability. Implantation resulted in pulsating grafts without leakage. One week after implantation, both ePTFE and the natural acellular graft had 100% patencies on duplex scanning. Grafts were partially endothelialised (Von Willebrand-positive endothelium with a laminin-positive basal membrane layer). After one month, layered thrombi were found in the natural (4/4) and ePTFE graft (1/4), resulting in occlusion which in case of the natural graft is likely due to the porosity of the inner elastin layer. In vivo application of a molecularly-defined tubular graft, based on nature's matrix proteins, for vascular surgery is feasible. PMID:26060888
Ionizing radiation effects on ISS ePTFE jacketed cable assembly
NASA Astrophysics Data System (ADS)
Koontz, S. L.; Golden, J. L.; Lorenz, M. J.; Pedley, M. D.
2003-09-01
Polytetrafluoroethylene (PTFE), which is susceptible to embrittlement by ionizing radiation, is used as a primary material in the Mobile Transporter's (MT) Trailing Umbilical System (TUS) cable on the International Space Station (ISS). The TUS cable provides power and data service between the ISS truss and the MT. The TUS cable is normally stowed in an uptake reel and is fed out to follow the MT as it moves along rails on the ISS truss structure. For reliable electrical and mechanical performance, TUS cable polymeric materials must be capable of >3.5% elongation without cracking or breaking. The MT TUS cable operating temperature on ISS is expected to range between -100°C and +130°C. The on-orbit functional life requirement for the MT TUS cable is 10 years. Analysis and testing were performed to verify that the MT TUS cable would be able to meet full-life mechanical and electrical performance requirements, despite progressive embrittlement by the natural ionizing radiation environment. Energetic radiation belt electrons (trapped electrons) are the principal contributor to TUS cable radiation dose. TUS cable specimens were irradiated, in vacuum, with both energetic electrons and gamma rays. Electron beam energy was chosen to minimize charging effects on the non-conductive ePTFE (expanded PTFE) targets. Tensile testing was then performed, over the expected range of operating temperatures, as a function of radiation dose. When compared to the expected in-flight radiation dose/depth profile, atomic oxygen (AO) erosion of the radiation damaged TUS cable jacket surfaces is more rapid than the development of radiation induced embrittlement of the same surfaces. Additionally, the layered construction of the jacket prevents crack growth propagation, leaving the inner layer material compliant with the design elongation requirements. As a result, the TUS cable insulation design was verified to meet performance life requirements.
Xu, Tong-yi; Zhang, Zhi-gang; Li, Xin; Han, Lin; Xu, Zhi-yun
2014-01-01
Background Since 2000, transcatheter pulmonary valve replacement has steadily advanced. However, the available prosthetic valves are restricted to bioprosthesis which have defects like poor durability. Polymeric heart valve is thought as a promising alternative to bioprosthesis. In this study, we introduced a novel polymeric transcatheter pulmonary valve and evaluated its feasibility and safety in sheep by a hybrid approach. Methods We designed a novel polymeric trileaflet transcatheter pulmonary valve with a balloon-expandable stent, and the valve leaflets were made of 0.1-mm expanded polytetrafluoroethylene (ePTFE) coated with phosphorylcholine. We chose glutaraldehyde-treated bovine pericardium valves as control. Pulmonary valve stents were implanted in situ by a hybrid transapical approach in 10 healthy sheep (8 for polymeric valve and 2 for bovine pericardium valve), weighing an average of 22.5±2.0 kg. Angiography and cardiac catheter examination were performed after implantation to assess immediate valvular functionality. After 4-week follow-up, angiography, echocardiography, computed tomography, and cardiac catheter examination were used to assess early valvular function. One randomly selected sheep with polymeric valve was euthanized and the explanted valved stent was analyzed macroscopically and microscopically. Findings Implantation was successful in 9 sheep. Angiography at implantation showed all 9 prosthetic valves demonstrated orthotopic position and normal functionality. All 9 sheep survived at 4-week follow-up. Four-week follow-up revealed no evidence of valve stent dislocation or deformation and normal valvular and cardiac functionality. The cardiac catheter examination showed the peak-peak transvalvular pressure gradient of the polymeric valves was 11.9±5.0 mmHg, while that of two bovine pericardium valves were 11 and 17 mmHg. Gross morphology demonstrated good opening and closure characteristics. No thrombus or calcification was seen macroscopically. Conclusions This design of the novel ePTFE transcatheter pulmonary valve is safe and effective to deploy in sheep by hybrid approach, and the early valvular functionality is good. PMID:24926892
Amphiphobic Polytetrafluoroethylene Membranes for Efficient Organic Aerosol Removal.
Feng, Shasha; Zhong, Zhaoxiang; Zhang, Feng; Wang, Yong; Xing, Weihong
2016-04-06
Polytetrafluoroethylene (PTFE) membrane is an extensively used air filter, but its oleophilicity leads to severe fouling of the membrane surface due to organic aerosol deposition. Herein, we report the fabrication of a new amphiphobic 1H,1H,2H,2H-perfluorodecyl acrylate (PFDAE)-grafted ZnO@PTFE membrane with enhanced antifouling functionality and high removal efficiency. We use atomic-layer deposition (ALD) to uniformly coat a layer of nanosized ZnO particles onto porous PTFE matrix to increase surface area and then subsequently graft PFDAE with plasma. Consequently, the membrane surface showed both superhydrophobicity and oleophobicity with a water contact angle (WCA) and an oil contact angle (OCA) of 150° and 125°, respectively. The membrane air permeation rate of 513 (m(3) m(-2) h(-1) kPa(-1)) was lower than the pristine membrane rate of 550 (m(3) m(-2) h(-1) kPa(-1)), which indicates the surface modification slightly decreased the membrane air permeation. Significantly, the filtration resistance of this amphiphobic membrane to the oil aerosol system was much lower than the initial one. Moreover, the filter exhibited exceptional organic aerosol removal efficiencies that were greater than 99.5%. These results make the amphiphobic PTFE membranes very promising for organic aerosol-laden air-filtration applications.
In Vitro Hemocompatibility of Thin Film Nitinol In Stenotic Flow Conditions
Kealey, C.P.; Whelan, S.A.; Chun, Y.J.; Soojung, C.H.; Tulloch, A.W.; Mohanchandra, K.P.; DiCarlo, D; Levi, D.S.; Carman, G.P.; Rigberg, D.A.
2010-01-01
Because of its low profile and biologically inert behavior, thin film nitinol (TFN) is ideally suited for use in construction of endovascular devices. We have developed a surface treatment for TFN designed to minimize platelet adhesion by creating a super-hydrophilic surface. The hemocompatibility of expanded polytetrafluorethylene (ePTFE), untreated thin film nitinol (UTFN), and a surface treated superhydrophilic thin film nitinol (STFN) was compared using an in vitro circulation model with whole blood under flow conditions simulating a moderate arterial stenosis. Scanning electron microscopy analysis showed increased thrombus on ePTFE as compared to UTFN or STFN. Total blood product deposition was 6.3 ± 0.8 mg/cm2 for ePTFE, 4.5 ± 2.3 mg/cm2 for UTFN, and 2.9 ± 0.4 mg/cm2 for STFN (n = 12, p < 0.01). ELISA assay for fibrin showed 326 ± 42 µg/cm2 for ePTFE, 45.6 ± 7.4 µg/cm2 for UTFN, and 194 ± 25 µg/cm2 for STFN (n = 12, p < 0.01). Platelet deposition measured by fluorescent intensity was 79,000 ± 20000 AU/mm2 for ePTFE, 810 ± 190 AU/mm2 for UTFN, and 1600 ± 25 AU/mm2 for STFN (n = 10, p < 0.01). Mass spectrometry demonstrated a larger number of proteins on ePTFE as compared to either thin film. UTFN and STFN appear to attract significantly less thrombus than ePTFE. Given TFN's low profile and our previously demonstrated ability to place TFN covered stents in vivo, it is an excellent candidate for use in next-generation endovascular stents grafts. PMID:20810163
Nittami, Tadashi; Hitomi, Tetsuo; Matsumoto, Kanji; Nakamura, Kazuho; Ikeda, Takaharu; Setoguchi, Yoshihiro; Motoori, Manabu
2012-01-01
This study focused on phase separation of activated sludge mixed liquor by flat-sheet membranes of polytetrafluoroethylene (PTFE). A 20 liter working volume lab-scale MBR incorporating immersed PTFE flat-sheet membrane modules with different pore sizes (0.3, 0.5 and 1.0 μm) was operated for 19 days treating a synthetic wastewater. The experiment was interrupted twice at days 5 and 13 when the modules were removed and cleaned physically and chemically in sequence. The pure water permeate flux of each membrane module was measured before and after each cleaning step to calculate membrane resistances. Results showed that fouling of membrane modules with 0.3 μm pore size was more rapid than other membrane modules with different pore sizes (0.5 and 1.0 μm). On the other hand, it was not clear whether fouling of the 0.5 μm membrane module was more severe than that of the 1.0 μm membrane module. This was partly because of the membrane condition after chemical cleaning, which seemed to determine the fouling of those modules over the next period. When irreversible resistance (Ri) i.e., differences in membrane resistance before use and after chemical cleaning was high, the transmembrane pressure increased quickly during the next period irrespective of membrane pore size. PMID:24958174
Zhang, Yuanzheng; Fang, Shuo; Dai, Jiezhi; Zhu, Lei; Fan, Hao; Tang, Weiya; Fan, Yongjie; Dai, Haiying; Zhang, Peipei; Wang, Ying; Xing, Xin; Yang, Chao
2017-01-01
To explore the repairing effect of combination of adipose stem cells (ASCs) and composite scaffolds on CWR, the electrospun Poly 1, 8-octanediol-co-citric acid (POC)-poly-L-lactide acid (PLA) composite scaffolds were prepared, followed by in vitro and in vivo biocompatibility evaluation of the scaffolds. Afterwards, ASCs were seeded on POC-PLA to construct the POC-PLA-ASCs scaffolds, and the POC-PLA, POC-PLA-ASCs, and traditional materials expanded polytetrafluoroethylene (ePTFE) were adopt for CWR in New Zealand white (NZW) rabbit models. As results, the POC-PLA-ASCs patches possessed good biocompatibility as the high proliferation ability of cells surrounding the patches. Rabbits in POC-PLA-ASCs groups showed better pulmonary function, less pleural adhesion, higher degradation rate and more neovascularization when compared with that in other two groups. The results of western blot indicated that POC-PLA-ASCs patches accelerated the expression of VEGF and Collagen I in rabbit models. From the above, our present study demonstrated that POC-PLA material was applied for CWR successfully, and ASCs seeded on the sheets could improve the pleural adhesions and promote the reparation of chest wall defects.
Rim, Yonghoon; Laing, Susan T; McPherson, David D; Kim, Hyunggun
2014-01-01
Mitral valve (MV) repair using expanded polytetrafluoroethylene sutures is an established and preferred interventional method to resolve the complex pathophysiologic problems associated with chordal rupture. We developed a novel computational evaluation protocol to determine the effect of the artificial sutures on restoring MV function following valve repair. A virtual MV was created using three-dimensional echocardiographic data in a patient with ruptured mitral chordae tendineae (RMCT). Virtual repairs were designed by adding artificial sutures between the papillary muscles and the posterior leaflet where the native chordae were ruptured. Dynamic finite element simulations were performed to evaluate pre- and post-repair MV function. Abnormal posterior leaflet prolapse and mitral regurgitation was clearly demonstrated in the MV with ruptured chordae. Following virtual repair to reconstruct ruptured chordae, the severity of the posterior leaflet prolapse decreased and stress concentration was markedly reduced both in the leaflet tissue and the intact native chordae. Complete leaflet coaptation was restored when four or six sutures were utilized. Computational simulations provided quantitative information of functional improvement following MV repair. This novel simulation strategy may provide a powerful tool for evaluation and prediction of interventional treatment for RMCT.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fanelli, Fabrizio, E-mail: fabrizio.fanelli@uniroma1.it; Bezzi, Mario; Bruni, Antonio
2011-02-15
We assessed, in a prospective study, the efficacy of multidetector spiral computed tomography (MDCT) in the evaluation of transjugular intrahepatic portosystemic shunt (TIPS) patency in patients treated with the Viatorr (Gore, Flagstaff, AZ) expanded-polytetrafluoroethylene (e-PTFE)-covered stent-graft. Eighty patients who underwent TIPS procedure using the Viatorr self-expanding e-PTFE stent-graft were evaluated at follow-up of 1, 3, 6, and 12 months with clinical and laboratory tests as well as ultrasound-color Doppler (USCD) imaging. In case of varices, upper gastrointestinal endoscopy was also performed. In addition, the shunt was evaluated using MDCT at 6 and 12 months. In all cases of abnormal findingsmore » and discrepancy between MDCT and USCD, invasive control venography was performed. MDCT images were acquired before and after injection of intravenous contrast media on the axial plane and after three-dimensional reconstruction using different algorithms. MDCT was successfully performed in all patients. No artefacts correlated to the Viatorr stent-graft were observed. A missing correlation between UCSD and MDCT was noticed in 20 of 80 (25%) patients. Invasive control venography confirmed shunt patency in 16 (80%) cases and shunt malfunction in 4 (20%) cases. According to these data, MDCT sensitivity was 95.2%; specificity was 96.6%; and positive (PPV) and negative predictive values (NPV) were 90.9 and 98.2%, respectively. USCD sensitivity was 90%; specificity was 75%; and PPV and NPV were 54.5 and 95.7%, respectively. A high correlation (K value = 0.85) between MDCT and invasive control venography was observed. On the basis of these results, MDCT shows superior sensitivity and specificity compared with USCD in those patients in whom TIPS was performed with the Viatorr stent-graft. MDCT can be considered a valid tool in the follow-up of these patients.« less
Liu, Jing Hua; Jeon, Min Ku; Lee, Ki Rak; Woo, Seong Ihl
2010-12-14
A combinatorial library of membrane-electrode-assemblies (MEAs) which consisted of 27 different compositions was fabricated to optimize the multilayer structure of direct methanol fuel cells. Each spot consisted of three layers of ink and a gradient was generated by employing different concentrations of the three components (Pt catalyst, Nafion® and polytetrafluoroethylene (PTFE)) of each layer. For quick evaluation of the library, a high-throughput optical screening technique was employed for methanol electro-oxidation reaction (MOR) activity. The screening results revealed that gradient layers could lead to higher MOR activity than uniform layers. It was found that the MOR activity was higher when the concentrations of Pt catalyst and Nafion ionomer decreased downward from the top layer to the bottom layer. On the other hand, higher MOR activity was observed when PTFE concentration increased downward from the top to the bottom layer.
2007-12-01
aqueous and aqueous electrolytes are kept separate by a non-electronically conducting ceramic membrane impervious to water, but with a high ionic...thought of as being solvated by the ceramic membrane as it passes from non-aqueous to aqueous electrolyte. The half-cell reaction at the lithium...overall charge in the reaction, positive lithium ions flow through an ionically conducting ceramic membrane from the non-aqueous anode compartment to
NASA Astrophysics Data System (ADS)
Lan, Yan; You, Qingliang; Cheng, Cheng; Zhang, Suzhen; Ni, Guohua; Nagatsu, M.; Meng, Yuedong
2011-02-01
Surface modification on a polytetrafluoroethylene (PTFE) panel was performed with sequential nitrogen plasma treatments and surface-initiated polymerization. By introducing COO- groups to the surface of the PTFE panel through grafting polymerization of acrylic acid (AA), a transparent poly (acrylic acid) (PAA) membrane was achieved from acrylic acid solution. Grafting polymerization initiating from the active groups was achieved on the PTFE panel surface after the nitrogen plasma treatment. Utilizing the acrylic acid as monomers, with COO- groups as cross link sites to form reticulation structure, a transparent poly (acrylic acid) membrane with arborescent macromolecular structure was formed on the PTFE panel surface. Analysis methods, such as fourier transform infrared spectroscopy (FTIR), microscopy and X-ray photoelectron spectroscopy (XPS), were utilized to characterize the structures of the macromolecule membrane on the PTFE panel surface. A contact angle measurement was performed to characterize the modified PTFE panels. The surface hydrophilicities of modified PTFE panels were significantly enhanced after the plasma treatment. It was shown that the grafting rate is related to the treating time and the power of plasma.
Coleman, Jessica G; Lotufo, Guilherme R; Kennedy, Alan J; Poda, Aimee R; Rushing, Todd S; Ruiz, Carlos E; Bridges, Todd S
2014-07-01
In benthic sediment bioassays, determining the relative contribution to exposure by contaminants in overlying water, porewater, and sediment particles is technically challenging. The purpose of the present study was to assess the potential for membranes to be utilized as a mechanism to allow freely dissolved hydrophobic organic contaminants into a pathway isolation exposure chamber (PIC) while excluding all sediment particles and dissolved organic carbon (DOC). This investigation was conducted in support of a larger effort to assess contaminant exposure pathways to benthos. While multiple passive samplers exist for estimating concentrations of contaminants in porewater such as those using solid-phase micro extraction (SPME) and polyoxymethylene (POM), techniques to effectively isolate whole organism exposure to porewater within a sediment system are not available. We tested the use of four membranes of different pore sizes (0.1-1.2μm) including nylon, polycarbonate, polyethylsulfone, and polytetrafluoroethylene with a hydrophilic coating. Exposures included both diffusion of radiolabeled and non-labeled contaminants across membranes from aqueous, sediment slurry, and whole sediment sources to assess and evaluate the best candidate membrane. Data generated from the present study was utilized to select the most suitable membrane for use in the larger bioavailability project which sought to assess the relevance of functional ecology in bioavailability of contaminated sediments at remediation sites. The polytetrafluoroethylene membrane was selected for use in the PIC, although exclusion of dissolved organic carbon was not achieved. Published by Elsevier Ltd.
In Vitro Tensile Strength Study on Suturing Technique and Material.
González-Barnadas, Albert; Camps-Font, Octavi; Espanya-Grifoll, Dunia; España-Tost, Antoni; Figueiredo, Rui; Valmaseda-Castellón, Eduard
2017-06-01
Suture technique and materials are important in preventing complications such as wound dehiscences. The purpose of this study was to determine the tensile strength of different suturing techniques, comparing several materials with different diameters. One hundred sixty sutures were performed using silk, e-PTFE, and 2 types of polyamide (monofilament and Supramid). Ten simple, 10 horizontal mattress, and 10 combinations of the two stitches were performed with 4-0 gauge of each material. Additionally, 10 simple sutures were performed with the 5-0 gauge of each material. The maximum tensile force resisted by each suture was recorded. When 5 mm of traction was applied, the polyamide monofilament resisted significantly better without untying or breaking compared with Supramid or silk, while the e-PTFE was superior to all the others. However, the force when e-PTFE 4-0 sutures untied or broke was lower than for either type of polyamide. The combined technique withstood a significantly higher tensile force before unknotting or breaking than did the simple and mattress stitches. The 5-0 gauges of silk and both types of polyamide showed lower tensile strengths than the 4-0 materials. Among the 5-0 sutures, Supramid showed a higher tensile strength than silk. The combined suture technique possessed greater tensile strength than did a simple or a horizontal mattress suture, and e-PTFE 4-0 withstood more traction without untying or breaking than did all the other materials, although at a lower tensile force. With the exception of e-PTFE, 4-0 sutures had greater tensile strength than did 5-0 sutures.
Zhu, Youbing; Yu, Shuili; Zhang, Bing; Li, Jianfeng; Zhao, Dongsheng; Gu, Zhengyang; Gong, Chao; Liu, Guicai
2018-06-18
Alkali/surfactant/polymer (ASP) flooding wastewater is highly caustic, and membrane fouling is the main obstacle during ASP ultrafiltration (UF) treatment. To maintain favorable filtration performance, polytetrafluoroethylene (PTFE) and polyvinylidene fluoride (PVDF) membranes were implemented here, and their antifouling properties and mechanisms were investigated based on the threshold flux theory. Compared with the PVDF membranes, the PTFE membranes exhibited superior antifouling properties with lower reductions in flux and smaller hydraulic resistance, and they presented a nearly identical pseudo-stable fouling rate at a later time point. In the fouling layers of the PTFE and PVDF membranes, anion polyacrylamide (APAM) was observed along with divalent/trivalent metal ions. The thermodynamic and molecular mechanisms of membrane fouling by APAM were elucidated using the Extended Derjaguin-Landau-Verwey-Overbeek (XDLVO) theory and atomic force microscopy (AFM), respectively. The calculated total interfacial free energy (mJ/m 2 ) of adhesion between the APAM and PTFE membranes was positive, and the value between the APAM and PVDF membranes was negative. Furthermore, the values and interaction distances of the measured intermolecular rupture and approaching forces were larger for APAM-PTFE than for APAM-PVDF. For the PTFE membranes, the positive free energies and smaller intermolecular interaction resulted in weaker APAM-PTFE adhesion and adsorption and therefore the lower levels of flux decline and the later achievement of the pseudo-stable fouling rate. Additionally, the total flux recoveries observed after physical cleaning reached 0.78-0.80 and 0.32-0.39 for the PTFE and PVDF membranes, respectively, which showed that the PTFE membranes can be cleaned easily. The PTFE membranes have considerable potential for extensive application in UF treatments for ASP wastewater. These results should promote understanding the essence of the threshold flux and the fouling control of UF membranes. Copyright © 2018. Published by Elsevier B.V.
NASA Astrophysics Data System (ADS)
Ito, Hiroshi; Iwamura, Takuya; Someya, Satoshi; Munakata, Tetsuo; Nakano, Akihiro; Heo, Yun; Ishida, Masayoshi; Nakajima, Hironori; Kitahara, Tatsumi
2016-02-01
This experimental study identifies the effect of through-plane polytetrafluoroethylene (PTFE) distribution in gas diffusion backing (GDB) on the performance of proton exchange membrane fuel cells (PEMFC). PTFE-drying under vacuum pressure created a relatively uniform PTFE distribution in GDB compared to drying under atmospheric pressure. Carbon paper samples with different PTFE distributions due to the difference in drying conditions were prepared and used for the cathode gas diffusion layer (GDL) of PEMFCs. Also investigated is the effect of MPL application on the performance for those samples. The current density (i) - voltage (V) characteristics of these PEMFCs measured under high relative humidity conditions clearly showed that, with or without MPL, the cell using the GDL with PTFE dried under vacuum condition showed better performance than that dried under atmospheric condition. It is suggested that this improved performance is caused by the efficient transport of liquid water through the GDB due to the uniform distribution of PTFE.
Mitral valve repair in dogs using an ePTFE chordal implantation device: a pilot study.
Borgarelli, M; Lanz, O; Pavlisko, N; Abbott, J A; Menciotti, G; Aherne, M; Lahmers, S M; Lahmers, K K; Gammie, J S
2017-06-01
Mitral valve (MV) regurgitation due to degenerative MV disease is the leading cause of cardiac death in dogs. We carried out preliminary experiments to determine the feasibility and short-term effects of beating-heart MV repair using an expanded polytetrafluorethylene (ePTFE) chordal implantation device (Harpoon TSD-5) in dogs. This study involved six healthy purpose-bred Beagles (weight range 8.9-11.4 kg). Following a mini-thoracotomy performed under general anesthesia, the TSD-5 was used to place 1 or 2 artificial ePTFE cords on the anterior MV leaflet or the posterior MV leaflet via a left-ventricular transapical approach. The procedure was guided and monitored by transesophageal echocardiography. Postoperative antithrombotic treatment consisted of clopidogrel or a combination of clopidogrel and apixaban. Dogs were serially evaluated by transthoracic echocardiography at day 1, 7, 14, 21, and 30. The hearts were then examined for evaluation of tissues reactions and to detect signs of endothelialization. One or two chords were successfully implanted in five dogs. Four dogs completed the 30 days follow-up. One dog died intra-operatively because of aortic perforation. One dog died early post-operatively from a hemorrhagic pleural effusion attributed to overly aggressive antithrombotic treatment. One dog developed a thrombus surrounding both the knot and the synthetic cord. Postmortem exam confirmed secure placement of ePTFE knots in the mitral leaflets in all dogs and the presence of endothelialization of the knots and chords. These preliminary results demonstrate the feasibility of artificial chordal placement using an ePTFE cordal implantation device in dogs. Copyright © 2017 Elsevier B.V. All rights reserved.
Omniphobic Membrane for Robust Membrane Distillation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lin, SH; Nejati, S; Boo, C
2014-11-01
In this work, we fabricate an omniphobic microporous membrane for membrane distillation (MD) by modifying a hydrophilic glass fiber membrane with silica nanoparticles followed by surface fluorination and polymer coating. The modified glass fiber membrane exhibits an anti-wetting property not only against water but also against low surface tension organic solvents that easily wet a hydrophobic polytetrafluoroethylene (PTFE) membrane that is commonly used in MD applications. By comparing the performance of the PTFE and omniphobic membranes in direct contact MD experiments in the presence of a surfactant (sodium dodecyl sulfate, SDS), we show that SDS wets the hydrophobic PTFE membranemore » but not the omniphobic membrane. Our results suggest that omniphobic membranes are critical for MD applications with feed waters containing surface active species, such as oil and gas produced water, to prevent membrane pore wetting.« less
Nano-Engineered Catalysts for Direct Methanol Fuel Cells
NASA Technical Reports Server (NTRS)
Myung, Nosang; Narayanan, Sekharipuram; Wiberg, Dean
2008-01-01
Nano-engineered catalysts, and a method of fabricating them, have been developed in a continuing effort to improve the performances of direct methanol fuel cells as candidate power sources to supplant primary and secondary batteries in a variety of portable electronic products. In order to realize the potential for high energy densities (as much as 1.5 W h/g) of direct methanol fuel cells, it will be necessary to optimize the chemical compositions and geometric configurations of catalyst layers and electrode structures. High performance can be achieved when catalyst particles and electrode structures have the necessary small feature sizes (typically of the order of nanometers), large surface areas, optimal metal compositions, high porosity, and hydrophobicity. The present method involves electrodeposition of one or more catalytic metal(s) or a catalytic-metal/polytetrafluoroethylene nanocomposite on an alumina nanotemplate. The alumina nanotemplate is then dissolved, leaving the desired metal or metal/polytetrafluoroethylene-composite catalyst layer. Unlike some prior methods of making fine metal catalysts, this method does not involve processing at elevated temperature; all processing can be done at room temperature. In addition, this method involves fewer steps and is more amenable to scaling up for mass production. Alumina nanotemplates are porous alumina membranes that have been fabricated, variously, by anodizing either pure aluminum or aluminum that has been deposited on silicon by electronbeam evaporation. The diameters of the pores (7 to 300 nm), areal densities of pores (as much as 7 x 10(exp 10)sq cm), and lengths of pores (up to about 100 nm) can be tailored by selection of fabrication conditions. In a given case, the catalytic metal, catalytic metal alloy, or catalytic metal/ polytetrafluoroethylene composite is electrodeposited in the pores of the alumina nanotemplate. The dimensions of the pores, together with the electrodeposition conditions, determine the sizes and surface areas of the catalytic particles. Hence, the small features and large surface areas of the porosity translate to the desired small particle size and large surface area of the catalyst (see figure). When polytetrafluoroethylene is included, it is for the purpose of imparting hydrophobicity in order to prevent water from impeding the desired diffusion of gases through the catalyst layer. To incorporate polytetrafluoroethylene into a catalytic-metal/polytetrafluoroethylene nanocomposite, one suspends polytetrafluoroethylene nanoparticles in the electrodeposition solution. The polytetrafluoroethylene content can be varied to obtain the desired degree of hydrophobicity and permeability by gas.
Novel synthetic selectively degradable vascular prostheses: a preliminary implantation study.
Izhar, U; Schwalb, H; Borman, J B; Hellener, G R; Hotoveli-Salomon, A; Marom, G; Stern, T; Cohn, D
2001-02-01
Vascular grafts perform less well than autologous arterial or vein grafts. The purpose of this study was to evaluate the short-term performance of selectively biodegradable filament-wound vascular prostheses, comprising elastomeric poly(ether urethane) (Lycra) scaffolds and flexible, hydrophilic biodegradable coatings. Two types of selectively biodegradable vascular grafts were manufactured, comprising a filament-wound Lycra scaffold, subsequently coated with a biodegradable poly(ethylene glycol)/poly(lactic acid) (PELA) block copolymer. The two types of grafts differed in both the overall porosity of the scaffold and the hydrophilicity of the biodegradable constituent. A 60-mm-long and 6-mm-diameter filament-wound and polytetrafluoroethylene (ePTFE) grafts were implanted as interposition prostheses, randomly, at the right- and left-side carotid arteries. Implantation studies proved the grafts to be patent and pulsatile for periods of up to 3 months. Increasing the scaffold porosity and enhancing the hydrophilicity of the biodegradable component improved both the transmural tissue ingrowth process and the vascularization of the prosthesis wall. Also, a well-adhered peripheral tissue and a thin, uniform intima and endothelial lining were obtained. All ePTFE graft controls, although patent, were rather stiff and nonpulsatile. A thick pseudointima, poorly attached to the prosthesis inner surface, was observed. The compliance of the wet grafts was significantly higher than in the dry state, stemming mainly from the water-plasticizing effect on the biodegradable component. The grafts explanted after a period of 6 weeks exhibited compliance only slightly lower than that of the wet grafts. After 12 weeks, however, the hoop compliance was 20% lower than that prior to implantation. At 100 mm Hg, for example, the original compliance of the wet graft was 2.5%/100 mm Hg decreasing to 2.0%/100 mm Hg after a 3-month implantation. The compliance reduction with implantation is attributed to the ingrowth of the perigraft tissue as revealed by the histological study. A compliance of 2.0%/100 mm Hg is slightly better than that of a standard PTFE graft with an original compliance of 1.6%/100 mm Hg. Yet it is still an order of magnitude smaller than that of a canine carotid artery. The improved mechanical properties and enhanced healing of the highly porous filament-wound Lycra scaffold graft coated with hydrophilic biodegradable PELA has the potential of being a highly effective small caliber prosthetic graft. Copyright 2000 Academic Press.
A novel low-profile thin-film nitinol/silk endograft for treating small vascular diseases.
Shayan, Mahdis; Yang, Sungyeun; Ryu, WonHyoung; Chun, Youngjae
2017-04-01
Since the introduction of various endovascular graft materials such as expanded polytetrafluoroethylene (e-PTFE) and Dacron ® polyester, they have been rapidly applied in endovascular devices for treating a variety of clinical situations. While present endovascular grafts have been successful in treating large blood vessels, there are still significant challenges and limitations for small and tortuous vessels to their use. Recently, our group has demonstrated the potential to use thin-film nitinol (TFN) as a novel material to develop endografts used in the treatment of a wide range of small vascular diseases because TFN is ultralow profile (that is, a few micrometers thick), relatively thromboresistant, and superelastic. While TFN has shown superior thromboresistance, its surface endothelialization is not rapid and sufficient. Therefore, our laboratory has been exploring the feasibility of using thin-film silk as a novel coating for facilitating rapid and confluent endothelial cell growth. The purpose of this study is to fabricate a low-profile composite endograft using thin layers of nitinol and silk, and to evaluate both thrombogenicity as well as endothelial cell and smooth muscle cell responses. This study also evaluates the functionality of the composite endograft using an in vitro blood circulation model. © 2015 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 105B: 575-584, 2017. © 2015 Wiley Periodicals, Inc.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Maynar, Manuel; Llorens, Rafael; Lopez-Sanchez, Carmen
Purpose. A method to create an extraluminal femoropopliteal bypass graft using endovascular techniques was evaluated in situ on cadaver extremities in an attempt to develop a minimally invasive alternative technique for the management of infrainguinal occlusive arterial disease. Methods. The endovascular placement of an extraluminal femoropopliteal bypass graft was undertaken in 5 cadaver legs. Following percutaneous access to the popliteal artery (PA) or common femoral artery (CFA), a Rosch-Uchida needle was used to perforate the vascular wall, followed by the creation of an extraluminal tract using a looped wire and catheter. Once the desired level was reached the needle wasmore » again used to perforate the vascular wall of the proximal superficial femoral artery (SFA) or PA depending on the access used. Self-expanding expanded polytetrafluoroethylene (ePTFE) stent-grafts were then deployed to establish the extraluminal femoropopliteal bypass connecting the two arterial puncture sites. Following dilatation of the stent-graft, angiography was performed to assess the endoprostheses and to look for contrast leaks. Results. Technical success was achieved in all 5 legs. Procedure time varied from 15 to 30 min. The angiographic studies performed immediately after completion of the bypass procedure showed patency of the grafts with no evidence of kinking or leakage in any of the cases. Conclusion. This study has proved that the endovascular placement of an extraluminal femoropopliteal bypass graft in human cadaver legs using endovascular techniques under fluoroscopic control is technically feasible.« less
Nardo, Tiziana; Chiono, Valeria; Ciardelli, Gianluca; Tabrizian, Maryam
2016-02-01
Inert polytetrafluoroethylene (PTFE) membranes for periodontal regeneration suffer from weak osteoconductive properties. In this work, a strategy for hydroxyapatite (HAp) coating on PTFE films through an adhesive layer of self-polymerized 3,4-dihydroxy-DL-phenylalanine (polyDOPA) was developed to improve surface properties. Physico-chemical and morphological analysis demonstrated the deposition of polyDOPA and HAp, with an increase in surface roughness and wettability. A discontinuous coating was present after 14 days in PBS and MC3T3-E1 cells proliferation and adhesion were improved. Results confirmed the potential application of polyDOPA/HAp-coated films for periodontal disease treatments. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Fabricating PFPE Membranes for Microfluidic Valves and Pumps
NASA Technical Reports Server (NTRS)
Greer, Frank; White, Victor E.; Lee, Michael C.; Willis, Peter A.; Grunthaner, Frank J.; Rolland, Jason; Rolland, Jason
2009-01-01
A process has been developed for fabricating membranes of a perfluoropolyether (PFPE) and integrating them into valves and pumps in laboratory-on-achip microfluidic devices. Membranes of poly(tetrafluoroethylene) [PTFE] and poly(dimethylsilane) [PDMS] have been considered for this purpose and found wanting. By making it possible to use PFPE instead of PTFE or PDMS, the present process expands the array of options for further development of microfluidic devices for diverse applications that could include detection of biochemicals of interest, detection of toxins and biowarfare agents, synthesis and analysis of proteins, medical diagnosis, and synthesis of fuels.
Oxygen-consuming chlor alkali cell configured to minimize peroxide formation
Chlistunoff, Jerzy B [Los Alamos, NM; Lipp, Ludwig [Brookfield, CT; Gottesfeld, Shimshon [Niskayuna, NY
2006-08-01
Oxygen-consuming zero gap chlor-alkali cell was configured to minimize peroxide formation. The cell included an ion-exchange membrane that divided the cell into an anode chamber including an anode and a cathode chamber including an oxygen gas diffusion cathode. The cathode included a single-piece of electrically conducting graphitized carbon cloth. Catalyst and polytetrafluoroethylene were attached to only one side of the cloth. When the cathode was positioned against the cation exchange membrane with the catalyst side away from the membrane, electrolysis of sodium chloride to chlorine and caustic (sodium hydroxide) proceeded with minimal peroxide formation.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wei, Xiaoliang; Nie, Zimin; Luo, Qingtao
Driven by the motivation of searching for low-cost membrane alternatives, a novel nanoporous polytetrafluoroethylene/silica composite separator has been prepared and evaluated for its use in all-vanadium mixed-acid redox flow battery. This separator consisting of silica particles enmeshed in a polytetrafluoroethylene fibril matrix has no ion exchange capacity and is featured with unique nanoporous structures, which function as the ion transport channels in redox flow battery operation, with an average pore size of 38nm and a porosity of 48%. This separator has produced excellent electrochemical performance in the all-vanadium mixed-acid system with energy efficiency delivery comparable to Nafion membrane and superiormore » rate capability and temperature tolerance. The separator also demonstrates an exceptional capacity retention capability over extended cycling, offering additional operational latitude towards conveniently mitigating the capacity decay that is inevitable for Nafion. Because of the inexpensive raw materials and simple preparation protocol, the separator is particularly low-cost, estimated to be at least an order of magnitude more inexpensive than Nafion. Plus the proven chemical stability due to the same backbone material as Nafion, this separator possesses a good combination of critical membrane requirements and shows great potential to promote market penetration of the all-vanadium redox flow battery by enabling significant reduction of capital and cycle costs.« less
Hirani, Zakir M; Decarolis, James F; Lehman, Geno; Adham, Samer S; Jacangelo, Joseph G
2012-01-01
Nine different membrane bioreactor (MBR) systems with different process configurations (submerged and external), membrane geometries (hollow-fiber, flat-sheet, and tubular), membrane materials (polyethersulfone (PES), polyvinylidene fluoride (PVDF), and polytetrafluoroethylene (PTFE)) and membrane nominal pore sizes (0.03-0.2 μm) were evaluated to assess the impact of influent microbial concentration, membrane pore size and membrane material and geometries on removal of microbial indicators by MBR technology. The log removal values (LRVs) for microbial indicators increased as the influent concentrations increased. Among the wide range of MBR systems evaluated, the total and fecal coliform bacteria and indigenous MS-2 coliphage were detected in 32, 9 and 15% of the samples, respectively; the 50th percentile LRVs were measured at 6.6, 5.9 and 4.5 logs, respectively. The nominal pore sizes of the membranes, membrane materials and geometries did not show a strong correlation with the LRVs.
Coagulation and complement activation.
Christensen, K; Larsson, R; Emanuelsson, H; Elgue, G; Larsson, A
2001-02-01
The purpose of this investigation was to assess the effect of heparin coating of a new stent construction (Stent Graft, Jomed Implantate GmbH, Germany) on platelet and coagulation activity. Stent grafts with an ePTFE membrane interfoliated between two stents were deployed in tubings to form Chandler loops. Fresh human blood with a low concentration of heparin was rotated for 1 h, then collected and used for measurements of platelet number, thrombin-antithrombin complex (TAT), CD11b, C3a and C5b-9. There were five study groups: Group 1, conventional unmodified stents (n = 8); Group 2, untreated stent grafts (n = 8); Group 3, heparin-coated stents and untreated membrane (n = 7); Group 4, heparin-coated stents and membrane (n = 8); Group 5, heparin-coated PVC tubings with no stents (n = 8). There was a significant drop in platelet count, increase in TAT-values and CD11b expression in Groups 1-3 but not in Group 4 compared to Group 5. Examination by scanning electron microscopy revealed extensive activation on non-modified stents but almost no deposition of thrombotic material on heparin-modified stent grafts. With unmodified stents and membrane there were signs of significant activation of platelets and coagulation. In contrast, the heparin-coated stent graft induced much less alterations, indicating improved blood compatibility.
Ionomer-Membrane Water Processing Methods
NASA Technical Reports Server (NTRS)
MacCallum, Taber K. (Inventor); Kelsey, Laura (Inventor)
2016-01-01
This disclosure provides water processing apparatuses, systems, and methods for recovering water from wastewater such as urine. The water processing apparatuses, systems, and methods can utilize membrane technology for extracting purified water in a single step. A containment unit can include an ionomer membrane, such as Nafion(TradeMark) over a hydrophobic microporous membrane, such as polytetrafluoroethylene (PTFE). The containment unit can be filled with wastewater, and the hydrophobic microporous membrane can be impermeable to liquids and solids of the wastewater but permeable to gases and vapors of the wastewater, and the ionomer membrane can be permeable to water vapor but impermeable to one or more contaminants of the gases and vapors. The containment unit can be exposed to a dry purge gas to maintain a water vapor partial pressure differential to drive permeation of the water vapor, and the water vapor can be collected and processed into potable water.
Ionomer-Membrane Water Processing Apparatus
NASA Technical Reports Server (NTRS)
MacCallum, Taber K. (Inventor); Kelsey, Laura (Inventor)
2016-01-01
This disclosure provides water processing apparatuses, systems, and methods for recovering water from wastewater such as urine. The water processing apparatuses, systems, and methods can utilize membrane technology for extracting purified water in a single step. A containment unit can include an ionomer membrane, such as Nafion(Registered Trademark), over a hydrophobic microporous membrane, such as polytetrafluoroethylene (PTFE). The containment unit can be filled with wastewater, and the hydrophobic microporous membrane can be impermeable to liquids and solids of the wastewater but permeable to gases and vapors of the wastewater, and the ionomer membrane can be permeable to water vapor but impermeable to one or more contaminants of the gases and vapors. The containment unit can be exposed to a dry purge gas to maintain a water vapor partial pressure differential to drive permeation of the water vapor, and the water vapor can be collected and processed into potable water.
Ionomer-Membrane Water Processing Apparatus
NASA Technical Reports Server (NTRS)
MacCallum, Taber K. (Inventor); Kelsey, Laura Katrina (Inventor)
2017-01-01
This disclosure provides water processing apparatuses, systems, and methods for recovering water from wastewater such as urine. The water processing apparatuses, systems, and methods can utilize membrane technology for extracting purified water in a single step. A containment unit can include an ionomer membrane, such as Nafion.RTM., over a hydrophobic microporous membrane, such as polytetrafluoroethylene (PTFE). The containment unit can be filled with wastewater, and the hydrophobic microporous membrane can be impermeable to liquids and solids of the wastewater but permeable to gases and vapors of the wastewater, and the ionomer membrane can be permeable to water vapor but impermeable to one or more contaminants of the gases and vapors. The containment unit can be exposed to a dry purge gas to maintain a water vapor partial pressure differential to drive permeation of the water vapor, and the water vapor can be collected and processed into potable water.
The Effects of Local Warming on Surgical Site Infection
Dellinger, E. Patchen; Weber, James; Swenson, Ron Edward; Kent, Christopher D.; Swanson, Paul E.; Harmon, Kurt; Perrin, Margot
2015-01-01
Abstract Background: Surgical site infections (SSI) account for a major proportion of hospital-acquired infections. They are associated with longer hospital stay, readmissions, increased costs, mortality, and morbidity. Reducing SSI is a goal of the Surgical Care Improvement Project and identifying interventions that reduce SSI effectively is of interest. In a single-blinded randomized controlled trial (RCT) we evaluated the effect of localized warming applied to surgical incisions on SSI development and selected cellular (immune, endothelial) and tissue responses (oxygenation, collagen). Methods: After Institutional Review Board approval and consent, patients having open bariatric, colon, or gynecologic-oncologic related operations were enrolled and randomly assigned to local incision warming (6 post-operative treatments) or non-warming. A prototype surgical bandage was used for all patients. The study protocol included intra-operative warming to maintain core temperature ≥36°C and administration of 0.80 FIO2. Patients were followed for 6 wks for the primary outcome of SSI determined by U.S. Centers for Disease Control (CDC) criteria and ASEPSIS scores (additional treatment; presence of serous discharge, erythema, purulent exudate, and separation of the deep tissues; isolation of bacteria; and duration of inpatient stay). Tissue oxygen (PscO2) and samples for cellular analyses were obtained using subcutaneous polytetrafluoroethylene (ePTFE) tubes and oxygen micro-electrodes implanted adjacent to the incision. Cellular and tissue ePTFE samples were evaluated using flow cytometry, immunohistochemistry, and Sircol™ collagen assay (Biocolor Ltd., Carrickfergus, United Kingdom). Results: One hundred forty-six patients participated (n=73 per group). Study groups were similar on demographic parameters and for intra-operative management factors. The CDC defined rate of SSI was 18%; occurrence of SSI between groups did not differ (p=0.27). At 2 wks, warmed patients had better ASEPSIS scores (p=0.04) but this difference was not observed at 6 wks. There were no significant differences in immune, endothelial cell, or collagen responses between groups. On post-operative days one to two, warmed patients had greater PscO2 change scores with an average PscO2 increase of 9–10 mm Hg above baseline (p<0.04). Conclusions: Post-operative local warming compared with non-warming followed in this study, which included intra-operative warming to maintain normothermia and FIO2 level of 0.80, did not reduce SSI and had no effect on immune, endothelial cell presence, or collagen synthesis. PscO2 increased significantly with warming, however, the increase was modest and less than expected or what has been observed in studies testing other interventions. PMID:26125454
Kupčík, Rudolf; Zelená, Miroslava; Řehulka, Pavel; Bílková, Zuzana; Česlová, Lenka
2016-02-01
Hydrophobins are small proteins that play a role in a number of processes during the filamentous fungi growth and development. These proteins are characterized by the self-assembly of their molecules into an amphipathic membrane at hydrophilic-hydrophobic interfaces. Isolation and purification of hydrophobins generally present a challenge in their analysis. Hydrophobin SC3 from Schizophyllum commune was selected as a representative of class I hydrophobins in this work. A novel procedure for selective and effective isolation of hydrophobin SC3 based on solid-phase extraction with polytetrafluoroethylene microparticles loaded in a small self-made microcolumn is reported. The tailored binding of hydrophobins to polytetrafluoroethylene followed by harsh elution conditions resulted in a highly specific isolation of hydrophobin SC3 from the model mixture of ten proteins. The presented isolation protocol can have a positive impact on the analysis and utilization of these proteins including all class I hydrophobins. Hydrophobin SC3 was further subjected to reduction of its highly stable disulfide bonds and to chymotryptic digestion followed by mass spectrometric analysis. The isolation and digestion protocols presented in this work make the analysis of these highly hydrophobic and compact proteins possible. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
NASA Astrophysics Data System (ADS)
Kim, Jihoon; Lee, Yongkyu; Jeon, Jae-Deok; Kwak, Seung-Yeop
2018-04-01
A series of ion-exchange membranes for vanadium redox flow batteries (VRBs) are prepared by filling the pores of a poly(tetrafluoroethylene) (PTFE) substrate with sulfonated poly(ether ether ketone) (SPEEK) and microporous Engelhard titanosilicate-10 (ETS-10). The effects of ETS-10 incorporation and PTFE reinforcement on membrane properties and VRB single-cell performance are investigated using various characterization tools. The results show that these composite membranes exhibit improved mechanical properties and reduced vanadium-ion permeabilities owing to the interactions between ETS-10 and SPEEK, the suppressed swelling of PTFE, and the unique ETS-10 framework. The composite membrane with 3 wt% ETS-10 (referred to as "SE3/P") exhibits the best membrane properties and highest ion selectivity. The VRB system with the SE3/P membrane exhibits higher cell capacity, higher cell efficiency, and lower capacity decay than that with a Nafion membrane. These results indicate that this composite membrane has potential as an alternative to Nafion in VRB systems.
Flame Retardant Fibers for Human Space Exploration - Past, Present, and Future
NASA Technical Reports Server (NTRS)
Orndoff, Evelyne
2017-01-01
The National Aeronautics and Space Administration (NASA) has led the development of unique flame retardant fibers for the specific requirements of different space programs. Three of these fibers have greatly contributed to the safety of all the space missions since the Apollo program. Beta alumina-silica microfiber developed for the outer layer of the space suit after the Apollo 1 fire is no longer used and has been replaced by other glass fibers. Expanded polytetrafluoroethylene (e-PTFE) fiber used in the current spacesuit is mostly known today through its trade mark Gore-Tex®. Polybenzimidazole (PBI) filament fiber used in many applications from the Apollo to the Space Shuttle program is no longer available. More recently, TOR"TM" copolymer of polyimide fiber developed during the space shuttle program to resist the atomic oxygen present in Low Earth Orbit has been barely used. The high cost and narrow range of aeronautical and aerospace applications have, however, led to a limited production of these fibers. Only fibers that found niche markets survived. Yet, deep space exploration will require more of these inherently flame retardant fibers than what is available today. There is a need for new flame retardant fabrics inside the space vehicles as well as a need for logistics reduction for long term space missions. Materials like modacrylic and polyimide are good candidates for future flame retardant aerospace fabrics. New fabrics must be developed for astronauts' clothing, as well as crew quarters and habitat. Therefore, both staple and filament fibers of various linear densities are needed for a three years mission to Mars.
Sarkar, Sandip; Burriesci, Gaetano; Wojcik, Adam; Aresti, Nicholas; Hamilton, George; Seifalian, Alexander M
2009-04-16
Long-term patency of expanded polytetrafluoroethylene (ePTFE) small calibre cardiovascular bypass prostheses (<6mm) is poor because of thrombosis and intimal hyperplasia due to low compliance, stimulating the search for elastic alternatives. Wall porosity allows effective post-implantation graft healing, encouraging endothelialisation and a measured fibrovascular response. We have developed a novel poly (carbonate) urethane-based nanocomposite polymer incorporating polyhedral oligomeric silsesquioxane (POSS) nanocages (UCL-NANO) which shows anti-thrombogenicity and biostability. We report an extrusion-phase-inversion technique for manufacturing uniform-walled porous conduits using UCL-NANO. Image analysis-aided wall measurement showed that two uniform wall-thicknesses could be specified. Different coagulant conditions revealed the importance of low-temperature phase-inversion for graft integrity. Although minor reduction of pore-size variation resulted from the addition of ethanol or N,N-dimethylacetamide, high concentrations of ethanol as coagulant did not provide uniform porosity throughout the wall. Tensile testing showed the grafts to be elastic with strength being directly proportional to weight. The ultimate strengths achieved were above those expected from haemodynamic conditions, with anisotropy due to the manufacturing process. Elemental analysis by energy-dispersive X-ray analysis did not show a regional variation of POSS on the lumen or outer surface. In conclusion, the automated vertical extrusion-phase-inversion device can reproducibly fabricate uniform-walled small calibre conduits from UCL-NANO. These elastic microporous grafts demonstrate favourable mechanical integrity for haemodynamic exposure and are currently undergoing in-vivo evaluation of durability and healing properties.
Székács, Inna; Kaszás, Nóra; Gróf, Pál; Erdélyi, Katalin; Szendrő, István; Mihalik, Balázs; Pataki, Ágnes; Antoni, Ferenc A.; Madarász, Emilia
2013-01-01
Optical waveguide lightmode spectroscopic (OWLS) techniques were probed for monitoring ion permeation through channels incorporated into artificial lipid environment. A novel sensor set-up was developed by depositing liposomes or cell-derived membrane fragments onto hydrophilic polytetrafluoroethylene (PTFE) membrane. The fibrous material of PTFE membrane could entrap lipoid vesicles and the water-filled pores provided environment for the hydrophilic domains of lipid-embedded proteins. The sensor surface was kept clean from the lipid holder PTFE membrane by a water- and ion-permeable polyethylene terephthalate (PET) mesh. The sensor set-up was tested with egg yolk lecithin liposomes containing gramicidin ion channels and with cell-derived membrane fragments enriched in GABA-gated anion channels. The method allowed monitoring the move of Na+ and organic cations through gramicidin channels and detecting the Cl–-channel functions of the (α5β2γ2) GABAA receptor in the presence or absence of GABA and the competitive GABA-blocker bicuculline. PMID:24339925
Pedram, Sara; Mortaheb, Hamid Reza; Arefi-Khonsari, Farzaneh
2018-01-01
In order to obtain a durable cost-effective membrane for membrane distillation (MD) process, flat sheet polyethersulfone (PES) membranes were modified by an atmospheric pressure nonequilibrium plasma generated using a dielectric barrier discharge in a mixture of argon and hexamethyldisiloxane as the organosilicon precursor. The surface properties of the plasma-modified membranes were characterized by water contact angle (CA), liquid entry pressure, X-ray photoelectron spectroscopy, scanning electron microscopy, and atomic force microscopy. The water CA of the membrane was increased from 64° to 104° by depositing a Si(CH 3 )-rich thin layer. While the pristine PES membrane was not applicable in the MD process, the modified PES membrane could be applied for the first time in an air gap membrane distillation setup for the removal of benzene as a volatile organic compound from water. The experimental design using central composite design and response surface methodology was applied to study the effects of feed temperature, concentration, and flow rate as well as their binary interactions on the overall permeate flux and separation factor. The separation factor and permeation flux of the modified PES membrane at optimum conditions were comparable with those of commercial polytetrafluoroethylene membrane.
21 CFR 878.3500 - Polytetrafluoroethylene with carbon fibers composite implant material.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Polytetrafluoroethylene with carbon fibers... Prosthetic Devices § 878.3500 Polytetrafluoroethylene with carbon fibers composite implant material. (a) Identification. A polytetrafluoroethylene with carbon fibers composite implant material is a porous device...
Li, Jianfeng; Guan, Yunshan; Cheng, Fangqin; Liu, Yu
2015-12-01
Direct contact membrane distillation (DCMD) is one of the attractive technologies for high salinity brine treatment. In this study, four polytetrafluoroethylene (PTFE) membranes were examined in treating highly concentrated salt solutions. Results showed that non-supported membranes generally have a higher overall mass transfer coefficient but porosity seems to be the most important parameter controlling membrane flux and thermal efficiency. Supported membranes with large thickness had relatively higher thermal efficiency than small thickness. This can be attributed to their reduced heat loss through heat condition. In addition, KCl, NaCl and MgCl2 solutions showed distinct trends over flux decline at high salt concentrations (⩾2.0M). The difference in flux was largely due to the discrepancy in water activities of these solutions (KCl>NaCl>MgCl2). However, the effect of viscosity on permeate flux could not be neglected for MgCl2 at high salt concentrations as the suddenly increased viscosity could lead to serious temperature polarization. This study indicates that membrane distillation is a promising technology for high salinity brine treatment. Copyright © 2014 Elsevier Ltd. All rights reserved.
Orenstein, Sean B; Saberski, Ean R; Kreutzer, Donald L; Novitsky, Yuri W
2012-08-01
While synthetic prosthetics have essentially become mandatory for hernia repair, mesh-induced chronic inflammation and scarring can lead to chronic pain and limited mobility. Mesh propensity to induce such adverse effects is likely related to the prosthetic's material, weight, and/or pore size. We aimed to compare histopathologic responses to various synthetic meshes after short- and long-term implantations in mice. Samples of macroporous polyester (Parietex [PX]), heavyweight microporous polypropylene (Trelex[TX]), midweight microporous polypropylene (ProLite[PL]), lightweight macroporous polypropylene (Ultrapro[UP]), and expanded polytetrafluoroethylene (DualMesh[DM]) were implanted subcutaneously in mice. Four and 12 wk post-implantation, meshes were assessed for inflammation, foreign body reaction (FBR), and fibrosis. All meshes induced varying levels of inflammatory responses. PX induced the greatest inflammatory response and marked FBR. DM induced moderate FBR and a strong fibrotic response with mesh encapsulation at 12 wk. UP and PL had the lowest FBR, however, UP induced a significant chronic inflammatory response. Although inflammation decreased slightly for TX, marked FBR was present throughout the study. Of the three polypropylene meshes, fibrosis was greatest for TX and slightly reduced for PL and UP. For UP and PL, there was limited fibrosis within each mesh pore. Polyester mesh induced the greatest FBR and lasting chronic inflammatory response. Likewise, marked fibrosis and encapsulation was seen surrounding ePTFE. Heavier polypropylene meshes displayed greater early and persistent fibrosis; the reduced-weight polypropylene meshes were associated with the least amount of fibrosis. Mesh pore size was inversely proportional to bridging fibrosis. Moreover, reduced-weight polypropylene meshes demonstrated the smallest FBR throughout the study. Overall, we demonstrated that macroporous, reduced-weight polypropylene mesh exhibited the highest degree of biocompatibility at sites of mesh implantation. Copyright © 2012 Elsevier Inc. All rights reserved.
Mostafa, M. G.; Zhu, Bo; Cran, Marlene; Dow, Noel; Milne, Nicholas; Desai, Dilip
2017-01-01
Meat rendering operations produce stick water waste which is rich in proteins, fats, and minerals. Membrane distillation (MD) may further recover water and valuable solids, but hydrophobic membranes are contaminated by the fats. Here, commercial hydrophobic polytetrafluorethylene (PTFE) membranes with a hydrophilic polyurethane surface layer (PU-PTFE) are used for the first time for direct contact MD (DCMD) on real poultry, fish, and bovine stick waters. Metal membrane microfiltration (MMF) was also used to capture fats prior to MD. Although the standard hydrophobic PTFE membranes failed rapidly, PU-PTFE membranes effectively processed all stick water samples to colourless permeate with sodium rejections >99%. Initial clean solution fluxes 5–6 L/m2/h declined to less than half during short 40% water recovery tests for all stick water samples. Fish stick water uniquely showed reduced fouling and up to 78% water recovery. Lost flux was easily restored by rinsing the membrane with clean water. MMF prior to MD removed 92% of fats, facilitating superior MD performance. Differences in fouling between stick waters were attributed to temperature polarisation from higher melt temperature fats and relative proportions to proteins. Hydrophilic coated MD membranes are applicable to stick water processing but further studies should consider membrane cleaning and longer-term stability. PMID:28961203
An, Alicia Kyoungjin; Guo, Jiaxin; Jeong, Sanghyun; Lee, Eui-Jong; Tabatabai, S Assiyeh Alizadeh; Leiknes, TorOve
2016-10-15
This study investigated the applicability of membrane distillation (MD) to treat dyeing wastewater discharged by the textile industry. Four different dyes containing methylene blue (MB), crystal violet (CV), acid red 18 (AR18), and acid yellow 36 (AY36) were tested. Two types of hydrophobic membranes made of polytetrafluoroethylene (PTFE) and polyvinylidene fluoride (PVDF) were used. The membranes were characterized by testing against each dye (foulant-foulant) and the membrane-dye (membrane-foulant) interfacial interactions and their mechanisms were identified. The MD membranes possessed negative charges, which facilitated the treatment of acid and azo dyes of the same charge and showed higher fluxes. In addition, PTFE membrane reduced the wettability with higher hydrophobicity of the membrane surface. The PTFE membrane evidenced especially its resistant to dye absorption, as its strong negative charge and chemical structure caused a flake-like (loose) dye-dye structure to form on the membrane surface rather than in the membrane pores. This also enabled the recovery of flux and membrane properties by water flushing (WF), thereby direct-contact MD with PTFE membrane treating 100 mg/L of dye mixtures showed stable flux and superior color removal during five days operation. Thus, MD shows a potential for stable long-term operation in conjunction with a simple membrane cleaning process, and its suitability in dyeing wastewater treatment. Copyright © 2016 Elsevier Ltd. All rights reserved.
Periodontal and peri-implant bone regeneration: clinical and histologic observations.
Artzi, Z; Zohar, R; Tal, H
1997-02-01
The principle of guided tissue regeneration by barrier membranes to restore lost periodontal tissue around natural teeth has also been used around osseointegrated implants in an attempt to restore alveolar ridge defects. While most periodontal procedures in the literature describe root coverage by mucogingival surgery, which achieves healing through soft tissue attachment, regeneration of denuded root surfaces is performed by guided tissue regeneration using expanded polytetrafluoroethylene barrier membranes and demineralized freeze-dried bone allografts as inductive/conductive materials. In this study the technique is applied in two partially exposed cylindrical hydroxyapatite-coated implants in extraction sites in one patient. Surgical reentry in both sites is presented, with histologic examination revealing new bone formation on the exposed root surface and the hydroxyapatite-coated implants.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ito, Yoshihiro; Ochiai, Yasushi; Park, Y.S.
1997-02-19
Benzyl glutamate NCA was graft-polymerized onto a porous poly(tetrafluoroethylene) membrane in order to study the effects of pH and ionic strength on permeation rate. The membrane was first glow-discharged in the presence of ammonia in order to produce amino groups on the surface. Following graft polymerization the graft chains were hydrolyzed to yield poly(glutamic acid). The rate of water permeation through this poly(glutamic acid)-grafted polymer membrane was pH-dependent and found to be slow under high-pH conditions and fast under low-pH conditions. Under high-pH conditions, randomly coiled graft chains extend to close the pores. The chains form a helix structure andmore » open the pores under low-pH conditions. The magnitude of the permeation rate was dependent upon the length and density of graft chains. Ionic strength also affected the permeation rate. 39 refs., 7 figs., 2 tabs.« less
Continuous-flow water sampler for real-time isotopic water measurements
NASA Astrophysics Data System (ADS)
Carter, J.; Dennis, K.
2013-12-01
Measuring the stable isotopes of liquid water (δ18O and δD) is a tool familiar to many Earth scientists, but most current techniques require discrete sampling. For example, isotope ratio mass spectrometry requires the collection of aliquots of water that are then converted to CO2, CO or H2 for analysis. Similarly, laser-based techniques, such as Cavity Ring-Down Spectroscopy (CRDS) convert discrete samples (typically < 2μL) of liquid water to water vapor using a flash vaporization process. By requiring the use of discrete samples fine-scale spatial and temporal studies of changes in δ18O and δD are limited. Here we present a continuous-flow water sampler that will enable scientists to probe isotopic changes in real-time, with applications including, but not limited to, quantification of the 'amount effect' (Dansgaard, 1964) during an individual precipitation event or storm track, real-time mixing of water in river systems, and shipboard continuous water measurements (Munksgaard et al., 2012). Due to the inherent ability of CRDS to measure a continuous flow of water vapor it is an ideal candidate for interfacing with a continuous water sampling system. Here we present results from the first commercially available continuous-flow water sampler, developed by engineers at Picarro. This peripheral device is compatible with Picarro CRDS isotopic water analyzers, allowing real-time, continuous isotopic measurements of liquid water. The new device, which expands upon the design of Munskgaard et al. (2011), utilizes expanded polytetrafluoroethylene (ePTFE) membrane technology to continuously generate gas-phase water, while liquid water is pumped through the system. The water vapor subsequently travels to the CRDS analyzer where the isotopic ratios are measured and recorded. The generation of water vapor using membrane technology is sensitive to environmental conditions, which if not actively control, lead to sustainable experimental noise and drift. Consequently, our continuous-flow water sample employs active control for all pertinent parameters, significantly increasing its stability and usability. We will present data from controlled laboratory experiments demonstrating sample-to-sample precision and long-term stability. We will also show experimental data that highlights the instrumental sample-to-sample memory, which we have decreased significantly from previous implementations of this technology. Additionally, we will present field results from the Sacramento River, CA. Dansgaard, W. (1964) 'Stable isotopes in precipitation', Tellus, 16(4), p. 436-468. Munksgaard, N.C., Wurster, C.M., Bass, A., Zagorskis, I., and Bird, M.I. (2012) 'First continuous shipboard d18O and dD measurements in seawater by diffusion sampling--cavity ring-down spectrometry', Environmental Chemistry Letters, 10, p.301-307. Munksgaard, N.C., Wurster, C.M., and Bird, M.I., (2011), 'Continuous analysis of δ18O and δD values of water by diffusion sampling cavity ring-down spectrometry: a novel sampling device for unattended field monitoring of precipitation, ground and surface waters', Rapid Communications in Mass Spectrometry, 25, p. 3706-3712.
Polymeric membranes for guided bone regeneration.
Gentile, Piergiorgio; Chiono, Valeria; Tonda-Turo, Chiara; Ferreira, Ana M; Ciardelli, Gianluca
2011-10-01
In this review, different barrier membranes for guided bone regeneration (GBR) are described as a useful surgical technique to enhance bone regeneration in damaged alveolar sites before performing implants and fitting other dental appliances. The GBR procedure encourages bone regeneration through cellular exclusion and avoids the invasion of epithelial and connective tissues that grow at the defective site instead of bone tissue. The barrier membrane should satisfy various properties, such as biocompatibility, non-immunogenicity, non-toxicity, and a degradation rate that is long enough to permit mechanical support during bone formation. Other characteristics such as tissue integration, nutrient transfer, space maintenance and manageability are also of interest. In this review, various non-resorbable and resorbable commercially available membranes are described, based on expanded polytetrafluoroethylene, poly(lactic acid), poly(glycolic acid) and their copolymers. The polyester-based membranes are biodegradable, permit a single-stage procedure, and have higher manageability than non-resorbable membranes; however, they have shown poor biocompatibility. In contrast, membranes based on natural materials, such as collagen, are biocompatible but are characterized by poor mechanical properties and stability due to their early degradation. Moreover, new approaches are described, such as the use of multi-layered, graft-copolymer-based and composite membranes containing osteoconductive ceramic fillers as alternatives to conventional membranes. Copyright © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
76 FR 8774 - Granular Polytetrafluoroethylene Resin From Japan
Federal Register 2010, 2011, 2012, 2013, 2014
2011-02-15
... INTERNATIONAL TRADE COMMISSION [Investigation No. 731-TA-386 (Third Review)] Granular Polytetrafluoroethylene Resin From Japan AGENCY: United States International Trade Commission. ACTION: Termination of five... revocation of the antidumping duty order on granular polytetrafluoroethylene resin from Japan would be likely...
Reversible Self-Actuated Thermo-Responsive Pore Membrane
Park, Younggeun; Gutierrez, Maria Paz; Lee, Luke P.
2016-01-01
Smart membranes, which can selectively control the transfer of light, air, humidity and temperature, are important to achieve indoor climate regulation. Even though reversible self-actuation of smart membranes is desirable in large-scale, reversible self-regulation remains challenging. Specifically, reversible 100% opening/closing of pore actuation showing accurate responsiveness, reproducibility and structural flexibility, including uniform structure assembly, is currently very difficult. Here, we report a reversible, thermo-responsive self-activated pore membrane that achieves opening and closing of pores. The reversible, self-actuated thermo-responsive pore membrane was fabricated with hybrid materials of poly (N-isopropylacrylamide), (PNIPAM) within polytetrafluoroethylene (PTFE) to form a multi-dimensional pore array. Using Multiphysics simulation of heat transfer and structural mechanics based on finite element analysis, we demonstrated that pore opening and closing dynamics can be self-activated at environmentally relevant temperatures. Temperature cycle characterizations of the pore structure revealed 100% opening ratio at T = 40 °C and 0% opening ratio at T = 20 °C. The flexibility of the membrane showed an accurate temperature-responsive function at a maximum bending angle of 45°. Addressing the importance of self-regulation, this reversible self-actuated thermo-responsive pore membrane will advance the development of future large-scale smart membranes needed for sustainable indoor climate control. PMID:27991563
Reversible Self-Actuated Thermo-Responsive Pore Membrane
NASA Astrophysics Data System (ADS)
Park, Younggeun; Gutierrez, Maria Paz; Lee, Luke P.
2016-12-01
Smart membranes, which can selectively control the transfer of light, air, humidity and temperature, are important to achieve indoor climate regulation. Even though reversible self-actuation of smart membranes is desirable in large-scale, reversible self-regulation remains challenging. Specifically, reversible 100% opening/closing of pore actuation showing accurate responsiveness, reproducibility and structural flexibility, including uniform structure assembly, is currently very difficult. Here, we report a reversible, thermo-responsive self-activated pore membrane that achieves opening and closing of pores. The reversible, self-actuated thermo-responsive pore membrane was fabricated with hybrid materials of poly (N-isopropylacrylamide), (PNIPAM) within polytetrafluoroethylene (PTFE) to form a multi-dimensional pore array. Using Multiphysics simulation of heat transfer and structural mechanics based on finite element analysis, we demonstrated that pore opening and closing dynamics can be self-activated at environmentally relevant temperatures. Temperature cycle characterizations of the pore structure revealed 100% opening ratio at T = 40 °C and 0% opening ratio at T = 20 °C. The flexibility of the membrane showed an accurate temperature-responsive function at a maximum bending angle of 45°. Addressing the importance of self-regulation, this reversible self-actuated thermo-responsive pore membrane will advance the development of future large-scale smart membranes needed for sustainable indoor climate control.
Zhang, Zinxin; Mwadini, Mwadini Ahmada; Chen, Zilin
2016-10-01
Steel stirrers jacketed with polytetrafluoroethylene can be regarded as an ideal substrate for stirrer bar sorptive extraction. However, it is still a great challenge to immobilize graphene onto a polytetrafluoroethylene stirrer due to the high chemical resistance of the surface of a polytetrafluoroethylene stirrer. We describe here a method to modify the surface of polytetrafluoroethylene stirrers with graphene. In this work, graphene was used as the sorbent due to its excellent adsorption capability for aromatic compounds, such as polycyclic aromatic compounds. Graphene was successfully immobilized onto polytetrafluoroethylene-stirrer by a bio-inspired polydopamine functionalization method. The graphene-modified polytetrafluoroethylene-stirrer shows good stability and tolerance to stirring, ultrasonication, strong acidic and basic solutions, and to organic solvents. The multilayer coating was characterized by scanning electronic microscopy and Fourier transform infrared spectroscopy. After the optimization of some experimental conditions, the graphene-modified polytetrafluoroethylene stirrer was used for the stirrer bar sorptive extraction of polycyclic aromatic hydrocarbons, in which the binding between the polycyclic aromatic hydrocarbons and the graphene layer was mainly based on π-π stacking and hydrophobic interactions. The graphene-modified polytetrafluoroethylene-stirrer-based stirrer bar sorptive extraction and high-performance liquid chromatography method was developed for the determination of polycyclic aromatic hydrocarbons with great extraction efficiency, with enrichment factors from 18 to 62. The method has low limits of detection of 1-5 pg/mL, wide linear range (5-100 and 10-200 pg/mL), good linearity (R ≥ 0.9957) and good reproducibility (RSD ≤ 6.45%). The proposed method has been applied to determine polycyclic aromatic hydrocarbons in real dust samples. Good recoveries were obtained, ranging from 88.53 to 109.43%. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
21 CFR 878.3500 - Polytetrafluoroethylene with carbon fibers composite implant material.
Code of Federal Regulations, 2010 CFR
2010-04-01
... composite implant material. 878.3500 Section 878.3500 Food and Drugs FOOD AND DRUG ADMINISTRATION... Prosthetic Devices § 878.3500 Polytetrafluoroethylene with carbon fibers composite implant material. (a) Identification. A polytetrafluoroethylene with carbon fibers composite implant material is a porous device...
Durability of hand-sewn valves in the right ventricular outlet.
Nunn, Graham R; Bennetts, Jayme; Onikul, Ella
2008-08-01
The objective was to compare the medium- and long-term outcomes for pericardial monocusp valves, polytetrafluoroethylene (Gore-Tex, WL Gore and Associates Inc, Flagstaff, Ariz) 0.1-mm monocusp valves, and bileaflet 0.l-mm polytetrafluoroethylene valves and their efficiency in the right ventricular outlet. We reviewed all hand-sewn right ventricular outlet valves created by the author (Graham R. Nunn) in the setting of repaired tetralogy of Fallot or equivalent right ventricular outlet pathology when the native pulmonary valve could not be preserved. The valves were assessed by serial transthoracic echocardiography and more recently by magnetic resonance imaging angiography for late valve function. The bileaflet polytetrafluoroethylene valves were constructed in a standardized fashion from a semicircle of 0.1-mm polytetrafluoroethylene (the radius of which equaled the length of the outflow tract incision) that gave a lengthened free edge to the leaflets, central fixation of the free edge posteriorly just proximal to the branch pulmonary arteries, and generous augmentation of the outflow tract with polytetrafluoroethylene patch-plasty. The bileaflet configuration shortens the closing time against the posterior wall, and the leaflets are forced to maintain their configuration without prolapse into the right ventricular outlet. The valve can be generously oversized in young children to try to avoid the need for replacement. A total of 54 patients met the selection criteria--22 patients received fresh autologous pericardial monocusps, 7 patients received polytetrafluoroethylene (0.1-mm) monocusps, and 25 patients received bileaflet polytetrafluoroethylene (0.1-mm) outlet valves. The pericardial valves have the longest follow-up, and all valves developed free pulmonary incompetence. Polytetrafluoroethylene monocusps had reliable competence early after surgery but progressed to pulmonary incompetence. The bileaflet polytetrafluoroethylene (0.1-mm) valves have remained competent with regurgitant fractions of only 5% to 30% (magnetic resonance imaging angiography), and this has remained stable with time. The maximum follow-up for these valves is 5 years. No stenosis or peripheral emboli have been recognized, and no valves have been replaced to date. Hand-sewn bileaflet polytetrafluoroethylene valves in the right ventricular outlet can reliably provide competence and maintain function in the medium term. Their shape and size allow placement in young children with a reasonable expectation that they will remain competent with growth of the native annulus and not require replacement. Their durability is superior to the pericardial and polytetrafluoroethylene monocusp valves in this series.
Jeon, Wonjae; Yun, Jongju; Khan, Fakhre Alam; Baik, Seunghyun
2015-09-14
Here we present a new strategy of selectively rejecting water vapor while allowing fast transport of dry gases using temperature-controlled aligned-multiwalled carbon nanotubes (aligned-MWNTs). The mechanism is based on the water vapor condensation at the entry region of nanotubes followed by removing aggregated water droplets at the tip of the superhydrophobic aligned-MWNTs. The first condensation step could be dramatically enhanced by decreasing the nanotube temperature. The permeate-side relative humidity was as low as ∼17% and the helium-water vapor separation factor was as high as 4.62 when a helium-water vapor mixture with a relative humidity of 100% was supplied to the aligned-MWNTs. The flow through the interstitial space of the aligned-MWNTs allowed the permeability of single dry gases an order of magnitude higher than the Knudsen prediction regardless of membrane temperature. The water vapor separation performance of hydrophobic polytetrafluoroethylene membranes could also be significantly enhanced at low temperatures. This work combines the membrane-based separation technology with temperature control to enhance water vapor separation performance.
Direct transfer of graphene onto flexible substrates.
Martins, Luiz G P; Song, Yi; Zeng, Tingying; Dresselhaus, Mildred S; Kong, Jing; Araujo, Paulo T
2013-10-29
In this paper we explore the direct transfer via lamination of chemical vapor deposition graphene onto different flexible substrates. The transfer method investigated here is fast, simple, and does not require an intermediate transfer membrane, such as polymethylmethacrylate, which needs to be removed afterward. Various substrates of general interest in research and industry were studied in this work, including polytetrafluoroethylene filter membranes, PVC, cellulose nitrate/cellulose acetate filter membranes, polycarbonate, paraffin, polyethylene terephthalate, paper, and cloth. By comparing the properties of these substrates, two critical factors to ensure a successful transfer on bare substrates were identified: the substrate's hydrophobicity and good contact between the substrate and graphene. For substrates that do not satisfy those requirements, polymethylmethacrylate can be used as a surface modifier or glue to ensure successful transfer. Our results can be applied to facilitate current processes and open up directions for applications of chemical vapor deposition graphene on flexible substrates. A broad range of applications can be envisioned, including fabrication of graphene devices for opto/organic electronics, graphene membranes for gas/liquid separation, and ubiquitous electronics with graphene.
Direct transfer of graphene onto flexible substrates
Martins, Luiz G. P.; Song, Yi; Zeng, Tingying; Dresselhaus, Mildred S.; Kong, Jing; Araujo, Paulo T.
2013-01-01
In this paper we explore the direct transfer via lamination of chemical vapor deposition graphene onto different flexible substrates. The transfer method investigated here is fast, simple, and does not require an intermediate transfer membrane, such as polymethylmethacrylate, which needs to be removed afterward. Various substrates of general interest in research and industry were studied in this work, including polytetrafluoroethylene filter membranes, PVC, cellulose nitrate/cellulose acetate filter membranes, polycarbonate, paraffin, polyethylene terephthalate, paper, and cloth. By comparing the properties of these substrates, two critical factors to ensure a successful transfer on bare substrates were identified: the substrate’s hydrophobicity and good contact between the substrate and graphene. For substrates that do not satisfy those requirements, polymethylmethacrylate can be used as a surface modifier or glue to ensure successful transfer. Our results can be applied to facilitate current processes and open up directions for applications of chemical vapor deposition graphene on flexible substrates. A broad range of applications can be envisioned, including fabrication of graphene devices for opto/organic electronics, graphene membranes for gas/liquid separation, and ubiquitous electronics with graphene. PMID:24127582
Lu, Joann J.; Zhu, Zaifang; Wang, Wei; Liu, Shaorong
2011-01-01
Sodium dodecyl sulfate (SDS)–polyacrylamide gel electrophoresis (PAGE) is a fundamental analytical technique for proteomic research, and SDS–capillary gel electrophoresis (CGE) is its miniaturized version. Compared to conventional slab-gel electrophoresis, SDS-CGE has many advantages such as increased separation efficiency, reduced separation time and automated operation. SDS-CGE is not widely accepted in proteomic research primarily due to the difficulties in identifying the well-resolved proteins. MALDI–TOF–MS is an outstanding platform for protein identifications. Coupling the two would solve the problem but is extremely challenging because the MS detector has no access to the SDS-CGE resolved proteins and the SDS interferes with MS detection. In this work we introduce an approach to address these issues. We discover that poly(tetrafluoroethylene) (PTFE) membranes are excellent materials for collecting SDS-CGE separated proteins. We demonstrate that we can wash off the SDS bound to the collected proteins and identify these proteins on-membrane with MALDI-TOF-MS. We also show that we can immunoblot and Coomassie-stain the proteins collected on these membranes. PMID:21309548
NASA Astrophysics Data System (ADS)
Cho, Min Kyung; Park, Hee-Young; Choe, Seunghoe; Yoo, Sung Jong; Kim, Jin Young; Kim, Hyoung-Juhn; Henkensmeier, Dirk; Lee, So Young; Sung, Yung-Eun; Park, Hyun S.; Jang, Jong Hyun
2017-04-01
To improve the cell performance for alkaline anion exchange membrane water electrolysis (AEMWE), the effects of the amount of polytetrafluoroethylene (PTFE) non-ionomeric binder in the anode and the hot-pressing conditions during the fabrication of the membrane electrode assemblies (MEAs) on cell performances are studied. The electrochemical impedance data indicates that hot-pressing at 50 °C for 1 min during MEA construction can reduce the polarization resistance of AEMWE by ∼12%, and increase the initial water electrolysis current density at 1.8 V (from 195 to 243 mA cm-2). The electrochemical polarization and impedance results also suggest that the AEMWE performance is significantly affected by the content of PTFE binder in the anode electrode, and the optimal content is found to be 9 wt% between 5 and 20 wt%. The AEMWE device fabricated with the optimized parameters exhibits good water splitting performance (299 mA cm-2 at 1.8 V) without noticeable degradation in voltage cycling operations.
Floating rGO-based black membranes for solar driven sterilization.
Zhang, Yao; Zhao, Dengwu; Yu, Fan; Yang, Chao; Lou, Jinwei; Liu, Yanming; Chen, Yingying; Wang, Zhongyong; Tao, Peng; Shang, Wen; Wu, Jianbo; Song, Chengyi; Deng, Tao
2017-12-14
This paper presents a new steam sterilization approach that uses a solar-driven evaporation system at the water/air interface. Compared to the conventional solar autoclave, this new steam sterilization approach via interfacial evaporation requires no complex system design to bear high steam pressure. In such a system, a reduced graphene oxide/polytetrafluoroethylene composite membrane floating at the water/air interface serves as a light-to-heat conversion medium to harvest and convert incident solar light into localized heat. Such localized heat raises the temperature of the membrane substantially and helps generate steam with a temperature higher than 120 °C. A sterilization device that takes advantage of the interfacial solar-driven evaporation system was built and its successful sterilization capability was demonstrated through both chemical and biological sterilization tests. The interfacial evaporation-based solar driven sterilization approach offers a potential low cost solution to meet the need for sterilization in undeveloped areas that lack electrical power but have ample solar radiation.
Kim, Hyun-Chul; Shin, Jaewon; Won, Seyeon; Lee, Jung-Yeol; Maeng, Sung Kyu; Song, Kyung Guen
2015-03-15
A fermentative strategy with an anaerobic moving bed biofilm reactor (AMBBR) was used for the treatment of domestic wastewater. The feasibility of using a membrane separation technique for post-treatment of anaerobic bio-effluent was evaluated with emphasis on employing a membrane distillation (MD). Three different hydrophobic 0.2 μm membranes made of polytetrafluoroethylene (PTFE), polyvinylidene fluoride (PVDF), and polypropylene (PP) were examined in this study. The initial permeate flux of the membranes ranged from 2.5 to 6.3 L m(-2) h(-1) when treating AMBBR effluent at a temperature difference between the feed and permeate streams of 20 °C, with the permeate flux increasing in the order PP < PVDF < PTFE. The permeate flux of the PTFE membrane gradually decreased to 84% of the initial flux after the 45 h run for distillation, while a flux decline in MD with either the PVDF or PP membrane was not found under the identical distillation conditions. During long-term distillation with the PVDF membrane, total phosphorus was completely rejected and >98% rejection of dissolved organic carbon was also achieved. The characterization of wastewater effluent organic matter (EfOM) using an innovative suite of analytical tools verified that almost all of the EfOM was rejected via the PVDF MD treatment. Copyright © 2015 Elsevier Ltd. All rights reserved.
Moustafa, Ahmed M A; Kim, Eun-Sik; Alpatova, Alla; Sun, Nian; Smith, Scott; Kang, Seoktae; Gamal El-Din, Mohamed
2014-01-01
The interaction between organic fractions in oil sands process-affected water (OSPW) and three polymeric membranes with varying hydrophilicity (nylon, polyvinylidene fluoride and polytetrafluoroethylene) at different pHs was studied to evaluate the impact of filtration on the quantification of acid-extractable fraction (AEF) and naphthenic acids (NAs). Four functional groups predominated in OSPW (amine, phosphoryl, carboxyl and hydroxyl) as indicated by the linear programming method. The nylon membranes were the most hydrophilic and exhibited the lowest AEF removal at pH of 8.7. However, the adsorption of AEF on the membranes increased as the pH of OSPW decreased due to hydrophobic interactions between the membrane surfaces and the protonated molecules. The use of ultra pressure liquid chromatography-high resolution mass spectrometry (UPLC/HRMS) showed insignificant adsorption of NAs on the tested membranes at pH 8.7. However, 26±2.4% adsorption of NAs was observed at pH 5.3 following the protonation of NAs species. For the nylon membrane, excessive carboxylic acids in the commercial NAs caused the formation of negatively charged assisted hydrogen bonds, resulting in increased adsorption at pH 8.2 (25%) as compared to OSPW (0%). The use of membranes for filtration of soluble compounds from complex oily wastewaters before quantification analysis of AEF and NAs should be examined prior to application.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Martin, G.G.; Cannon, G.C.; McCormick, C.L.
Extensive research is being done in many laboratories to investigate the role of synthetic hydrophobically-modified polymers and amphipathic proteins for their potential in phase-transfer, sequestration, and elimination of polluting hydrocarbons and surfactants. Our laboratory has begun a research program which is aimed at the development of a new class of environmentally benign biomaterials using the amphipathic proteins termed {open_quotes}hydrophobins{close_quotes} and an associated polysaccharide, schizophyllan. These biopolymers can stabilize oil dispersions, attach strongly to polyethylene and polytetrafluoroethylene surfaces rendering them hydrophilic, and can self-assemble into a stable, flexible membrane. Preliminary experiments in our laboratory and others have demonstrated the immense technologicalmore » potential of this class of biomaterials for surface modification of membranes and coatings, fouling resistance, controlled delivery, protective encapsulation, and drag reduction.« less
Liu, Yanfei; Bao, Chenghuan; Zhang, Jifei; Yang, Xing
2018-01-01
This study proposes using membrane distillation (MD) as an alternative to the conventional multi-stage flushing (MSF) process to concentrate a semi-product of organic fertilizer. By applying a unique asymmetric polyvinylidene fluoride (PVDF) membrane, which was specifically designed for MD applications using a nonsolvent thermally induced phase separation (NTIPS) method, the direct contact membrane distillation (DCMD) performance was investigated in terms of its sustainability in permeation flux, fouling resistance, and anti-wetting properties. It was found that the permeation flux increased with increasing flow rate, while the top-surface facing feed mode was the preferred orientation to achieve 25% higher flux than the bottom-surface facing feed mode. Compared to the commercial polytetrafluoroethylene (PTFE) membrane, the asymmetric PVDF membrane exhibited excellent anti-fouling and sustainable flux, with less than 8% flux decline in a 15 h continuous operation, i.e., flux decreased slightly and was maintained as high as 74 kg·m−2·h−1 at 70 °C. Meanwhile, the lost flux was easily recovered by clean water rinsing. Overall 2.6 times concentration factor was achieved in 15 h MD operation, with 63.4% water being removed from the fertilizer sample. Further concentration could be achieved to reach the desired industrial standard of 5x concentration factor. PMID:29462942
Kim, Myong; Hong, Bumsik; Park, Hyung Keun
2016-12-01
To evaluate the long-term clinical efficacy and safety of double-layered polytetrafluoroethylene membrane-covered self-expandable segmental metallic stents (Uventa) in patients with chronic ureteral obstruction. In a retrospective study, a total of 50 ureter units (44 patients) with chronic obstructions were included from July 2010 to May 2015. Indications for Uventa placement were primary stenting for malignant ureteral obstruction, failed conventional polymeric Double-J stent (PS), or percutaneous nephrostomy (PCN) technique, with comorbidities or fears limiting PS/PCN changes, or with irritation or pain due to PS/PCN. Patients underwent Uventa stent placement using the antegrade or retrograde approach. There were no immediate procedure-related complications, and all stents were placed in the proper sites. During the median follow-up of 30.9 (interquartile range [IQR], 8.1-49.0) months, the primary (no obstruction and no additional intervention) and overall success (no obstruction and no additional intervention except supplementary Uventa) was 30.0% and 34.0%, respectively. Moreover, 14 of 50 ureter units (28.0%) experienced major complications (≥Clavien-Dindo class IIIb), such as ureteroarterial fistula (three cases, 6.0%), ureteroenteric fistula (three, 6.0%), ureterovaginal fistula (one, 2.0%), ureter perforation (one, 2.0%), uncontrollable bleeding (one, 2.0%), and complete obstruction (five, 10.0%). On univariate analysis, major complications were associated with female (odds ratio [OR] = 6.000), cervical cancer (OR = 4.667), ureteral stricture length (≥6.0 cm, OR = 4.583), and placement duration (≥24.0 months, OR = 20.429; all p < 0.05). In long-term follow-up, the Uventa stent demonstrated poor treatment outcomes with frequent major complications in patients with chronic ureteral obstructions.
An implantable centrifugal blood pump with a recirculating purge system (Cool-Seal system).
Yamazaki, K; Litwak, P; Tagusari, O; Mori, T; Kono, K; Kameneva, M; Watach, M; Gordon, L; Miyagishima, M; Tomioka, J; Umezu, M; Outa, E; Antaki, J F; Kormos, R L; Koyanagi, H; Griffith, B P
1998-06-01
A compact centrifugal blood pump has been developed as an implantable left ventricular assist system. The impeller diameter is 40 mm, and pump dimensions are 55 x 64 mm. This first prototype, fabricated from titanium alloy, resulted in a pump weight of 400 g including a brushless DC motor. The weight of a second prototype pump was reduced to 280 g. The entire blood contacting surface is coated with diamond like carbon (DLC) to improve blood compatibility. Flow rates of over 7 L/min against 100 mm Hg pressure at 2,500 rpm with 9 W total power consumption have been measured. A newly designed mechanical seal with a recirculating purge system (Cool-Seal) is used for the shaft seal. In this seal system, the seal temperature is kept under 40 degrees C to prevent heat denaturation of blood proteins. Purge fluid also cools the pump motor coil and journal bearing. Purge fluid is continuously purified and sterilized by an ultrafiltration unit which is incorporated in the paracorporeal drive console. In vitro experiments with bovine blood demonstrated an acceptably low hemolysis rate (normalized index of hemolysis = 0.005 +/- 0.002 g/100 L). In vivo experiments are currently ongoing using calves. Via left thoracotomy, left ventricular (LV) apex descending aorta bypass was performed utilizing an expanded polytetrafluoroethylene (ePTFE) vascular graft with the pump placed in the left thoracic cavity. In 2 in vivo experiments, the pump flow rate was maintained at 5-9 L/min, and pump power consumption remained stable at 9-10 W. All plasma free Hb levels were measured at less than 15 mg/dl. The seal system has demonstrated good seal capability with negligible purge fluid consumption (<0.5 ml/day). In both calves, the pumps demonstrated trouble free continuous function over 6 month (200 days and 222 days).
Keefe, Morgan S; Keefe, Michael A
2009-01-01
Reconstruction in the head and neck can be difficult owing to the size of the defect or characteristics of the tissue that needs to be replaced. Facial wounds or reconstruction sites can be subject to contamination, thereby risking infection of any implanted material even under ideal circumstances. Particular areas of concern are sites where minimizing the bacterial contamination prior to placing an implant is difficult (eg, the oral cavity and internal nose). Reconstruction involves the facial subcutaneous soft tissue and/or bone, and the ideal implant provides support and natural feel, as well as a low risk of infection. The biocompatibility of alloplastic implants depends on the tissue inertness of the implant and the porosity, allowing connective tissue ingrowth, which in turn decreases the susceptibility to infection. Scalafani et al demonstrated that alloplastic implants contaminated prior to fibrovascular ingrowth had a much higher incidence of infection and rejection. To examine the effectiveness of several techniques for infiltrating antibiotics into alloplastic implants of different porosity using 2 commonly used alloplastic implants, expanded polytetrafluoroethylene (e-PTFE, or GORE-TEX) and porous high-density polyethylene (Medpor). Using an in vitro bacterial growth inhibition model, we found that suction infiltration of the implant with antibiotics was the most effective technique, with a statistically significant advantage over other techniques used. The advantages of the suction impregnation were seen to be most effective using alloplasts with a smaller pore size (20-30 microm) (P < .001), but there was a statistically significant difference even with implants with a larger pore size (150-200 microm) (P < .001). Suction infiltration of antibiotics into porous implants seems to be the most effective method identified using an in vitro testing protocol. Further experiments will be needed to confirm the effectiveness in reducing the perioperative risk of infection in vivo.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tande, Brian; Seames, Wayne; Benson, Steve
The objective of this project was to evaluate the use of composite polymer membranes and porous membrane contactors to regenerate physical and chemical solvents for capture of carbon dioxide (CO 2) from synthesis gas or flue gas, with the goal of improving the energy efficiency of carbon capture. Both a chemical solvent (typical for a post-combustion capture of CO 2 from flue gas) and a physical solvent (typical for pre- combustion capture of CO 2 from syngas) were evaluated using two bench-scale test systems constructed for this project. For chemical solvents, polytetrafluoroethylene and polypropylene membranes were found to be ablemore » to strip CO 2 from a monoethanolamine (MEA) solution with high selectivity without significant degradation of the material. As expected, the regeneration temperature was the most significant parameter affecting the CO 2 flux through the membrane. Pore size was also found to be important, as pores larger than 5 microns lead to excessive pore wetting. For physical solvents, polydimethyl-siloxane (PDMS)-based membranes were found to have a higher CO 2 permeability than polyvinylalcohol (PVOH) based membranes, while also minimizing solvent loss. Overall, however, the recovery of CO 2 in these systems is low – less than 2% for both chemical and physical solvents – primarily due to the small surface area of the membrane test apparatus. To obtain the higher regeneration rates needed for this application, a much larger surface area would be needed. Further experiments using, for example, a hollow fiber membrane module could determine if this process could be commercially viable.« less
NASA Astrophysics Data System (ADS)
Park, Byeong-Hee; Sohn, Joon-Yong; Shin, Junhwa
2016-01-01
In this study, a hydrophilic copolymer of acrylonitrile (AN) and sodium vinylsulfonate (SVS) was grafted into a highly hydrophobic porous poly(tetrafluoroethylene) (PTFE) substrate using a gamma-ray irradiation method and the grafted substrate was used as a substrate for impregnating a hydrophilic ionomer, Nafion. The results of FT-IR and TGA analysis of the prepared substrate showed that the SVS/AN monomers were successfully grafted into the porous PTFE film. The results of degree of grafting, elemental analyzer, and contact angle analysis showed that the hydrophilicity of the prepared PTFE-g-P(AN-co-VS) substrate was increased with an increase in the amount of SVS/AN graft copolymers. Also, the results of FE-SEM and Gurley number measurement showed that the pores in the substrate were reduced as the amount of SVS/AN copolymers grafted into the substrate increased. The prepared porous PTFE-g-P(AN-co-VS) substrate at an irradiation dose of 70 kGy was found to impregnate Nafion ionomer effectively compared to the original porous PTFE substrate. These results suggest that the prepared PTFE-g-P(AN-co-VS) substrate can be effectively used for the impregnation of polymer electrolyte (Nafion) to prepare a reinforced composite membrane.
Endothelialized ePTFE Graft by Nanobiotechnology
2013-11-29
The Apparatus for Processing the Tubular Graft Modification Will be Designed and Evaluated.; The On-site Capturing of the Endothelial (Progenitor) Cells by Peptide-mediated Selective Adhesion in Vitro and in Vivo Will Also be Elucidated.; The Patency Rate of ITRI-made Artificial Blood Vessels Will be Evaluated by the Porcine Animal Model.
Fractography can be used to analyze failure modes in polytetrafluoroethylene
NASA Technical Reports Server (NTRS)
Nerren, B. H.
1969-01-01
Fractographic principles used for analyzing failure in metals are applied to the analysis of the microstructure and fracture of polytetrafluoroethylene. This material is used as seals in cryogenic systems.
Gamal, A Y; Al-Berry, N N; Hassan, A A; Rashed, L A; Iacono, V J
2017-06-01
Migration of gingival fibroblasts/gingival mesenchymal stem cells through macro-perforated barrier membranes may allow them to participate positively in periodontal regeneration. The optimal guided tissue membrane perforation diameter that could favor maximum cell migration into the defect area and at the same time act as an occlusive barrier for gingival epithelium and its associated gingival extracellular matrix component is not yet identified. Cultured human gingival fibroblasts/gingival mesenchymal stem cells were placed in the upper chambers of 12-well collagen-coated polytetrafluoroethylene transwells, which were manually perforated with 0.2, 0.4 and 0.7 mm sized pores. The lower chambers of the transwells received blood clot as an attraction medium. The number of cells that have migrated to the lower chambers was calculated. Proliferation of these cells was evaluated using MTT assay. Scanning electron microscopy images were obtained for the lower surfaces of the transwell membranes. Perforated bovine collagen membranes (Tutopatch ® ) were subjected to mechanical testing to determine the tensile strength and modulus of elasticity. Group 3 (0.7 mm) showed significantly higher values for cell migration and proliferation. All groups showed a small degree of extracellular matrix migration through membrane perforations. Scanning electron microscopy evaluation revealed variable numbers of cells in fibrin matrices located mainly around the pore edges. There were non-significant differences between groups regarding mechanical properties. The present study demonstrated that macro-membrane perforations of 0.2, 0.4 and 0.7 mm are suitable pore diameters that could maintain membrane stiffness and allow for cellular migration. However, these membrane perforation diameters did not allow for total gingival connective tissue isolation. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Crystallinity enhancement of Nafion electrolyte membranes assisted by a molecular gelator.
Zhang, Wenjing; Yue, Po-Lock; Gao, Ping
2011-08-02
Nanocrystallites, acting as physical cross-links in Nafion membranes, play a crucial role in building blocks for improving mechanical durability and stopping fuel crossover. However, Nafion membranes suffer from low crystallinity due to the irregular pendent side chains, which hinder self-aggregation of the poly(tetrafluoroethylene) (PTFE) backbones. For the first time, a molecular gelator was introduced in the membrane casting process to enhance the rate of self-assembly of PTFE backbones so as to increase the membrane's crystallinity as well as proton conductivity without sacrificing the purity of Nafion. The molecular gelator used was 3,4-dimethylbenzaldehyde (DMBA). Addition of 0.5 wt % DMBA led to a 42% increase in crystallinity, a 32% increase in yield strength, a 22% increase in tensile modulus and an 18% increase in proton conductivity at 60 °C and 90% relative humidity. Additionally, the membrane electrode assembly (MEA) prepared from the membranes cast from the solution containing 0.5 wt % DMBA also showed an increase of 17% in maximum power density in comparison to the MEA prepared from pure Nafion membrane in a single cell polarization test without any external humidification. Transmission electron microscopy (TEM) and molecular dynamics simulation were used to elucidate the structural changes in Nafion membrane due to the introduction of DMBA. It was observed that the presence of DMBA gives wider crystalline regions under TEM. The molecular dynamics simulation at 500 K shows that the PTFE backbones become elongated in the presence of DMBA due to the enhanced mobility. This is consistent with the observed increase in crystallinity in the membrane as it means reduced entropic change upon crystallization.
Schleicher, Martina; Hansmann, Jan; Elkin, Bentsian; Kluger, Petra J.; Liebscher, Simone; Huber, Agnes J. T.; Fritze, Olaf; Schille, Christine; Müller, Michaela; Schenke-Layland, Katja; Seifert, Martina; Walles, Heike; Wendel, Hans-Peter; Stock, Ulrich A.
2012-01-01
In vivo self-endothelialization by endothelial cell adhesion on cardiovascular implants is highly desirable. DNA-oligonucleotides are an intriguing coating material with nonimmunogenic characteristics and the feasibility of easy and rapid chemical fabrication. The objective of this study was the creation of cell adhesive DNA-oligonucleotide coatings on vascular implant surfaces. DNA-oligonucleotides immobilized by adsorption on parylene (poly(monoaminomethyl-para-xylene)) coated polystyrene and ePTFE were resistant to high shear stress (9.5 N/m2) and human blood serum for up to 96 h. Adhesion of murine endothelial progenitor cells, HUVECs and endothelial cells from human adult saphenous veins as well as viability over a period of 14 days of HUVECs on oligonucleotide coated samples under dynamic culture conditions was significantly enhanced (P < 0.05). Oligonucleotide-coated surfaces revealed low thrombogenicity and excellent hemocompatibility after incubation with human blood. These properties suggest the suitability of immobilization of DNA-oligonucleotides for biofunctionalization of blood vessel substitutes for improved in vivo endothelialization. PMID:22481939
Excimer laser induced surface chemical modification of polytetrafluoroethylene
NASA Astrophysics Data System (ADS)
Révész, K.; Hopp, B.; Bor, Z.
1997-02-01
Polytetrafluoroethylene has a notoriously non adhesive and non reactive character. Its successful surface photochemical modification was performed by irradiating the polytetrafluoroethylene/liquid triethylamine interface with an ArF excimer laser (λ=193 nm). Due to the photochemical treatment the polytetrafluoroethylene surface became more hydrophilic. The water receding contact angle decreased from 94° to 43°. The reaction cross section was determined from the decrease of the contact angles. It was found to be as high as 6.4×10-18 cm2. XPS measurements evidenced the removal of fluorine from the polytetrafluoroethylene, incorporation of alkyl carbon and nitrogen. Photochemical dissociation path of the triethylamine makes probable that it bonded to the fluoropolymer backbone via the α-carbon atom of an ethyl group. A radical, or a photoinduced electron transfer mechanism was suggested to describe this reaction. A selective area electroless plating of silver was performed after pretreating the sample with patterned photomodification. The increased adhesion of the sample was proved by gluing with epoxy resin. As a result of the surface modification the tensile strength of gluing increased by 210× and reached 24% of the value characteristic for the bulk material.
Horng, Ren-Yang; Hsu, Shu-Fang; Chen, Shiao-Shing; Ho, Chia-Hua
2018-01-01
More than 80% of ammonia (NH3) in the steel manufacturing process wastewater is contributed from the coking wastewater, which is usually treated by biological processes. However, the NH3 in the coking wastewater is typically too high for biological treatment due to its inhibitory concentration. Therefore, a two-stage process including a hollow fiber membrane contactor (HFMC) and a modified membrane distillation (MD) system was developed and applied to reduce and recover NH3 from coking wastewater. The objectives of this paper are to evaluate different membrane materials, receiving solutions, and operation parameters for the system, remove NH3 from the coking wastewater to less than 300 mg N/L, which is amenable to the biological process, and recover ammonia solution for reuse. As a result, the polytetrafluoroethylene (PTFE) HFMC using sulfuric acid as a receiving solution can achieve a maximum NH3-N transmembrane flux of 1.67 g N/m2·h at pH of 11.5 and reduce NH3 in the coking wastewater to less than 300 mg N/L. The NH3 in the converted ammonium sulfate ((NH4)2SO4) was then recovered by the modified MD using ice water as the receiving solution to produce ≥3% of ammonia solution for reuse. PMID:29510505
Expanded polytetrafluoroethylene membrane alters tissue response to implanted Ahmed glaucoma valve.
DeCroos, Francis Char; Ahmad, Sameer; Kondo, Yuji; Chow, Jessica; Mordes, Daniel; Lee, Maria Regina; Asrani, Sanjay; Allingham, R Rand; Olbrich, Kevin C; Klitzman, Bruce
2009-07-01
Long-term intraocular pressure control by glaucoma drainage implants is compromised by the formation of an avascular fibrous capsule that surrounds the glaucoma implant and increases aqueous outflow resistance. It is possible to alter this fibrotic tissue reaction and produce a more vascularized and potentially more permeable capsule around implanted devices by enclosing them in a porous membrane. Ahmed glaucoma implants modified with an outer 5-microm pore size membrane (termed porous retrofitted implant with modified enclosure or PRIME-Ahmed) and unmodified glaucoma implants were implanted into paired rabbit eyes. After 6 weeks, the devices were explanted and subject to histological analysis. A tissue response containing minimal vascularization, negligible immune response, and a thick fibrous capsule surrounded the unmodified Ahmed glaucoma implant. In comparison, the tissue response around the PRIME-Ahmed demonstrated a thinner fibrous capsule (46.4 +/- 10.8 microm for PRIME-Ahmed versus 94.9 +/- 21.2 microm for control, p < 0.001) and was highly vascularized near the tissue-material interface. A prominent chronic inflammatory response was noted as well. Encapsulating the aqueous outflow pathway with a porous membrane produces a more vascular tissue response and thinner fibrous capsule compared with a standard glaucoma implant plate. Enhanced vascularity and a thinner fibrous capsule may reduce aqueous outflow resistance and improve long-term glaucoma implant performance.
Effect of simulation conditions on friction in polytetrafluoroethylene (PTFE)
NASA Astrophysics Data System (ADS)
Barry, Peter R.; Jang, Inkook; Perry, Scott S.; Sawyer, W. Gregory; Sinnott, Susan B.; Phillpot, Simon R.
2007-12-01
We report the results of molecular-dynamics simulations of friction at polytetrafluoroethylene (PTFE) interfaces and show that the calculated tribological properties are robust against significant changes in the sliding speed and the morphology of the polymer.
NASA Astrophysics Data System (ADS)
George, Michael G.; Wang, Jian; Banerjee, Rupak; Bazylak, Aimy
2016-03-01
The novel application of scanning transmission X-ray microscopy (STXM) to the microporous layer (MPL) of a polymer electrolyte membrane fuel cell is investigated. A spatially resolved chemical component distribution map is obtained for the MPL of a commercially available SGL 25 BC sample. This is achieved with near edge X-ray absorption fine structure spectroscopic analysis. Prior to analysis the sample is embedded in non-reactive epoxy and ultra-microtomed to a thickness of 100 nm. Polytetrafluoroethylene (PTFE), carbon particle agglomerates, and supporting epoxy resin distributions are identified and reconstructed for a scanning area of 6 μm × 6 μm. It is observed that the spatial distribution of PTFE is strongly correlated to the carbon particle agglomerations. Additionally, agglomerate structures of PTFE are identified, possibly indicating the presence of a unique mesostructure in the MPL. STXM analysis is presented as a useful technique for the investigation of chemical species distributions in the MPL.
NASA Astrophysics Data System (ADS)
George, Michael G.
Characterization of gas diffusion layers (GDLs) for polymer electrolyte membrane (PEM) fuel cells informs modeling studies and the manufacturers of next generation fuel cell materials. Identifying the physical properties related to the primary functions of the modern GDL (thermal, electrical, and mass transport) is necessary for understanding the impact of GDL design choices. X-ray micro-computed tomographic reconstructions of GDLs were studied to isolate GDL surface morphologies. Surface roughness was measured for a wide variety of samples and a sensitivity study highlighted the scale-dependence of surface roughness measurements. Furthermore, a spatially resolved distribution map of polytetrafluoroethylene (PTFE) in the microporous layer (MPL), critical for water management and mass transport, was identified and the existence of PTFE agglomerations was highlighted. Finally, the impact of accelerated degradation on GDL wettability and water transport increases in liquid water accumulation and oxygen mass transport resistance were quantified as a result of accelerated GDL degradation.
Tran, Clara T. H.; Kondyurin, Alexey; Hirsh, Stacey L.; McKenzie, David R.; Bilek, Marcela M. M.
2012-01-01
The surface of polytetrafluoroethylene (PTFE) was modified using plasma immersion ion implantation (PIII) with the aim of improving its ability to immobilize yeast. The density of immobilized cells on PIII-treated and -untreated PTFE was compared as a function of incubation time over 24 h. Rehydrated yeast cells attached to the PIII-treated PTFE surface more rapidly, with higher density, and greater attachment strength than on the untreated surface. The immobilized yeast cells were removed mechanically or chemically with sodium hydroxide and the residues left on the surfaces were analysed with Fourier transform infrared spectroscopy-attenuated total reflection (FTIR-ATR) and X-ray photoelectron spectroscopy (XPS). The results revealed that the mechanism of cell attachment on both surfaces differs and a model is presented for each. Rapid attachment on the PIII-treated surface occurs through covalent bonds of cell wall proteins and the radicals on the treated surface. In contrast, on the untreated surface, only physisorbed molecules were found in the residue and lipids were more highly concentrated than proteins. The presence of lipids in the residue was found to be a consequence of damage to the plasma membrane during the rehydration process and the increased cell stress was also apparent by the amount of Hsp12 in the protein residue. The immobilized yeast cells on PIII-treated PTFE were found to be as active as yeast cells in suspension. PMID:22696486
Percutaneous bail-out treatment of vein graft rupture with a polytetrafluoroethylene-covered stent.
Pavlidis, Antonios N; Karamasis, Grigorios V; Clapp, Brian R
2013-12-01
Vessel perforation is an undesirable and life-threatening complication during vein graft angioplasty. We report on a case of vein graft rupture during angioplasty, which was successfully managed with deployment of a polytetrafluoroethylene-covered stent.
ENVIRONMENTALLY-BENIGN POLYTETRAFLUOROETHYLENE (PTFE) COATINGS FOR MOLD RELEASE - PHASE II
GVD proposes to develop high performance, volatile organic compound (VOC)-free and perfluorooctanoic acid (PFOA)-free, non-stick mold release coatings based on its novel polytetrafluoroethylene (PTFE) fluoropolymer technology. Most commercial mold release agents make use of...
NASA Astrophysics Data System (ADS)
Cho, Min Kyung; Park, Hee-Young; Lee, Hye Jin; Kim, Hyoung-Juhn; Lim, Ahyoun; Henkensmeier, Dirk; Yoo, Sung Jong; Kim, Jin Young; Lee, So Young; Park, Hyun S.; Jang, Jong Hyun
2018-04-01
Herein, we investigate the effects of catholyte feed method and anode binder content on the characteristics of anion exchange membrane water electrolysis (AEMWE) to construct a high-performance electrolyzer, revealing that the initial AEMWE performance is significantly improved by pre-feeding 0.5 M aqueous KOH to the cathode. The highest long-term activity during repeated voltage cycling is observed for AEMWE operation in the dry cathode mode, for which the best long-term performance among membrane electrode assemblies (MEAs) featuring polytetrafluoroethylene (PTFE) binder-impregnated (5-20 wt%) anodes is detected for a PTFE content of 20 wt%. MEAs with low PTFE content (5 and 9 wt%) demonstrate high initial performance, rapid performance decay, and significant catalyst loss from the electrode during long-term operation, whereas the MEA with 20 wt% PTFE allows stable water electrolysis for over 1600 voltage cycles. Optimization of cell operating conditions (i.e., operation in dry cathode mode at an optimum anode binder content following an initial solution feed) achieves an enhanced water splitting current density (1.07 A cm-2 at 1.8 V) and stable long-term AEMWE performance (0.01% current density reduction per voltage cycle).
21 CFR 878.4520 - Polytetrafluoroethylene injectable.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Polytetrafluoroethylene injectable. 878.4520 Section 878.4520 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4520...
21 CFR 878.4520 - Polytetrafluoroethylene injectable.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Polytetrafluoroethylene injectable. 878.4520 Section 878.4520 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4520...
21 CFR 878.4520 - Polytetrafluoroethylene injectable.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Polytetrafluoroethylene injectable. 878.4520 Section 878.4520 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4520...
21 CFR 878.4520 - Polytetrafluoroethylene injectable.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Polytetrafluoroethylene injectable. 878.4520 Section 878.4520 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4520...
21 CFR 878.4520 - Polytetrafluoroethylene injectable.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Polytetrafluoroethylene injectable. 878.4520 Section 878.4520 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4520...
Mao, Xiangju; He, Man; Chen, Beibei; Hu, Bin
2016-11-11
By wrapping a porous membrane around the coated stir bar, a novel membrane protected stir bar sorptive extraction (MPSBSE) was proposed to filter out the high molecular weight interferences (such as humic acid), resulting in the analysis of real environmental water samples without filtration or centrifugation. Hydrophilic and hydrophobic membranes were compared and hydrophobic polytetrafluoroethylene (PTFE) membrane impregnated with methanol was employed to protect the C 18 coated stir bar. The impregnated methanol improves the transfer of target analytes from sample solution to the pores and lumen of the membrane, and then to the coated stir bar inside. By combining C 18 -MPSBSE with HPLC-UV, a method was proposed for the direct determination of two common non-steroidal anti-inflammatory drugs, Ketoprofen (KEP) and Naproxen (NAP) in complex water samples. Under the optimized conditions, the limit of detections of KEP and NAP are 7.89, 9.52μgL -1 in the waste water and 7.69, 6.90μgL -1 in the pure water, respectively, with the enrichment factors of 32.0-49.1-fold. Besides, the lifetime of the prepared C 18 stir bar protected by PTFE membrane (50 times) is longer than that of C 18 stir bar without membrane protection (20 times), indicating that the friction damage of SBSE coating during extraction was effectively avoided. The developed method was successfully applied to the analysis of KEP and NAP in domestic sewage and campus lake water samples. Copyright © 2016 Elsevier B.V. All rights reserved.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-10-18
... chemical production and polytetrafluoroethylene operations; from paint, resin, and adhesive manufacturing... miscellaneous industrial adhesives control techniques guideline (CTG) category in accordance with the... to COMAR 26.11.19.30 ``Control of VOC from Chemical Production and Polytetrafluoroethylene Operations...
Beloti, Márcio M; de Oliveira, Paulo T; Gimenes, Rossano; Zaghete, Maria A; Bertolini, Márcio J; Rosa, Adalberto L
2006-11-01
This study was aimed at investigating the in vitro biocompatibility of a novel membrane of the composite poly(vinylidene-trifluoroethylene)/barium titanate (P(VDF-TrFE)/BT). Osteoblastic cells were obtained from human alveolar bone fragments and cultured under standard osteogenic condition until subconfluence. First passaged cells were cultured on P(VDF-TrFE)/BT and expanded polytetrafluoroethylene (e-PTFE--control) membranes in 24-well plates. Cell adhesion and spreading were evaluated at 30 min, and 4 and 24 h. For proliferation assay, cells were cultured for 1, 7, and 10 days. Cell viability was detected by trypan blue at 7 and 10 days. Total protein content and alkaline phosphatase (ALP) activity were measured at 7, 14, and 21 days. Cultures were stained with Alizarin red at 21 days, for detection of mineralized matrix. Data were compared by ANOVA and Student t test. Cell attachment (p = 0.001), cell number (p = 0.001), and ALP activity (p = 0.0001) were greater on P(VDF-TrFE)/BT. Additionally, doubling time was greater on P(VDF-TrFE)/BT (p = 0.03), indicating a decreased proliferation rate. Bone-like nodule formation took place only on P(VDF-TrFE)/BT. The present results showed that both membranes are biocompatible. However, P(VDF-TrFE)/BT presented a better in vitro biocompatibility and allowed bone-like nodule formation. Therefore, P(VDF-TrFE)/BT could be an alternative membrane to be used in guided tissue regeneration.
Siria, Doreen J; Batista, Elis P A; Opiyo, Mercy A; Melo, Elizangela F; Sumaye, Robert D; Ngowo, Halfan S; Eiras, Alvaro E; Okumu, Fredros O
2018-04-11
Controlled blood-feeding is essential for maintaining laboratory colonies of disease-transmitting mosquitoes and investigating pathogen transmission. We evaluated a low-cost artificial feeding (AF) method, as an alternative to direct human feeding (DHF), commonly used in mosquito laboratories. We applied thinly-stretched pieces of polytetrafluoroethylene (PTFE) membranes cut from locally available seal tape (i.e. plumbers tape, commonly used for sealing pipe threads in gasworks or waterworks). Approximately 4 ml of bovine blood was placed on the bottom surfaces of inverted Styrofoam cups and then the PTFE membranes were thinly stretched over the surfaces. The cups were filled with boiled water to keep the blood warm (~37 °C), and held over netting cages containing 3-4 day-old inseminated adults of female Aedes aegypti, Anopheles gambiae (s.s.) or Anopheles arabiensis. Blood-feeding success, fecundity and survival of mosquitoes maintained by this system were compared against DHF. Aedes aegypti achieved 100% feeding success on both AF and DHF, and also similar fecundity rates (13.1 ± 1.7 and 12.8 ± 1.0 eggs/mosquito respectively; P > 0.05). An. arabiensis had slightly lower feeding success on AF (85.83 ± 16.28%) than DHF (98.83 ± 2.29%) though these were not statistically different (P > 0.05), and also comparable fecundity between AF (8.82 ± 7.02) and DHF (8.02 ± 5.81). Similarly, for An. gambiae (s.s.), we observed a marginal difference in feeding success between AF (86.00 ± 10.86%) and DHF (98.92 ± 2.65%), but similar fecundity by either method. Compared to DHF, mosquitoes fed using AF survived a similar number of days [Hazard Ratios (HR) for Ae. aegypti = 0.99 (0.75-1.34), P > 0.05; An. arabiensis = 0.96 (0.75-1.22), P > 0.05; and An. gambiae (s.s.) = 1.03 (0.79-1.35), P > 0.05]. Mosquitoes fed via this simple AF method had similar feeding success, fecundity and longevity. The method could potentially be used for laboratory colonization of mosquitoes, where DHF is unfeasible. If improved (e.g. minimizing temperature fluctuations), the approach could possibly also support studies where vectors are artificially infected with blood-borne pathogens.
Performance of a Cross-Flow Humidifier with a High Flux Water Vapor Transport Membrane
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ahluwalia, R. K.; Wang, X.; Johnson, W. B.
Water vapor transport (WVT) flux across a composite membrane that consists of a very thin perfluorosulfonic acid (PFSA) ionomer layer sandwiched between two expanded polytetrafluoroethylene (PTFE) microporous layers is investigated. Static and dynamic tests are conducted to measure WVT flux for different composite structures; a transport model shows that the underlying individual resistances for water diffusion in the gas phase and microporous and ionomer layers and for interfacial kinetics of water uptake at the ionomer surface are equally important under different conditions. A finite-difference model is formulated to determine water transport in a full-scale (2-m2 active membrane area) planar cross-flowmore » humidifier module assembled using pleats of the optimized composite membrane. In agreement with the experimental data, the modeled WVT flux in the module increases at higher inlet relative humidity (RH) of the wet stream and at lower pressures, but the mass transfer effectiveness is higher at higher pressures. The model indicates that the WVT flux is highest under conditions that maintain the wet stream at close to 100% RH while preventing the dry stream from becoming saturated. The overall water transport is determined by the gradient in RH of the wet and dry streams but is also affected by vapor diffusion in the gas layer and the microporous layer.« less
Performance assessment of membrane distillation for skim milk and whey processing.
Hausmann, Angela; Sanciolo, Peter; Vasiljevic, Todor; Kulozik, Ulrich; Duke, Mikel
2014-01-01
Membrane distillation is an emerging membrane process based on evaporation of a volatile solvent. One of its often stated advantages is the low flux sensitivity toward concentration of the processed fluid, in contrast to reverse osmosis. In the present paper, we looked at 2 high-solids applications of the dairy industry: skim milk and whey. Performance was assessed under various hydrodynamic conditions to investigate the feasibility of fouling mitigation by changing the operating parameters and to compare performance to widespread membrane filtration processes. Whereas filtration processes are hydraulic pressure driven, membrane distillation uses vapor pressure from heat to drive separation and, therefore, operating parameters have a different bearing on the process. Experimental and calculated results identified factors influencing heat and mass transfer under various operating conditions using polytetrafluoroethylene flat-sheet membranes. Linear velocity was found to influence performance during skim milk processing but not during whey processing. Lower feed and higher permeate temperature was found to reduce fouling in the processing of both dairy solutions. Concentration of skim milk and whey by membrane distillation has potential, as it showed high rejection (>99%) of all dairy components and can operate using low electrical energy and pressures (<10 kPa). At higher cross-flow velocities (around 0.141 m/s), fluxes were comparable to those found with reverse osmosis, achieving a sustainable flux of approximately 12 kg/h·m(2) for skim milk of 20% dry matter concentration and approximately 20 kg/h·m(2) after 18 h of operation with whey at 20% dry matter concentration. Copyright © 2014 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
Attempts to obtain re-osseointegration following experimental peri-implantitis in dogs.
Wetzel, A C; Vlassis, J; Caffesse, R G; Hämmerle, C H; Lang, N P
1999-04-01
The purpose of this study was to examine the healing potential and re-osseointegration in peri-implant infection defects adjacent to various implant surfaces. In 7 female Beagle dogs, a total of 41 titanium oral implants (ITI, Straumann, Waldenburg; Switzerland) with a sink depth of 6 mm (diameter 2.8 mm) were placed transmucosally. Four different surface configurations (TPS: titanium plasma sprayed (10); SLA: sand blasted and acid-etched (13); M: machined and smooth (11); TPS furc.: titanium plasma sprayed with coronally placed perforation to mimic a furcation (7) were distributed among the animals and locations. Following a healing period of 3 months, silk ligatures were placed and oral cleaning procedures abolished for 4 months to induce a vertical bone loss of about 40%. Following mechanical and chemical cleansing (chlorhexidine and metronidazole) and disinfection, the lesions were either sham operated (11) or subjected to a GTR procedure using ePTFE (30). After 6 months of healing the animals were killed and the jaws histologically evaluated. Six membranes were lost TPS: (1); SLA: (2); M: (2); TPS furc: (1) and 3 membranes exposed TPS: (1); M: (2) and excluded from further evaluation. Owing to the loss of 1 implant and infection of the membranes in the TPS furc group, this implant configuration was discarded from further analysis. For TPS surfaces, bone fill was 2.6 mm (73% of the distance from the bottom of the defect to the shoulder of the implant) sites with (4 GTR) and 0.33 mm (14%) for sites without membrane (2 controls). Re-osseointegration was 0.5 mm (14%) in the test group and 0.3 mm (14%) in the control. For SLA surfaces bone fill was 2.3 mm (83%) for sites with (7 GTR) and 0.41 mm (15%) for sites without membranes (4 controls). Re-osseointegration was 0.6 mm (20%) and 0.3 mm (11%) respectively. Corresponding values for M surfaces were 2.2 mm (62%) with 4 GTR) and 0.82 mm (31%) without membranes. Re-osseointegration was 0.07 mm (2%) and 0.19 mm (7%) respectively. This study has documented that peri-implant infections defects may heal with bone fill provided that the infection is controlled through effective antibacterial therapy. However, true reosseointegration appears to be difficult to achieve.
Gião, M S; Blanc, S; Porta, S; Belenguer, J; Keevil, C W
2015-07-01
To develop a gentle ablation technique to recover Listeria monocytogenes biofilms from stainless steel (SS) and polytetrafluoroethylene (PTFE) surfaces by using compressed air and water injection. Biofilms were grown for 4, 24 and 48 h or 7 days and a compressed air and water flow at 2, 3 and 4 bars was applied for cell removal. Collected cells were quantified for total/dead by staining with SYTO 9/PI double staining and cultivable populations were determined by plating onto brain heart infusion (BHI) agar, while coupon surfaces also were stained with DAPI to quantify in situ the remaining cells. The recovery efficiency was compared to that of conventional swabbing. Results showed that the air/water ablation is able to collect up to 98·6% of cells from SS surfaces while swabbing only recovered 11·2% of biofilm. Moreover, air/water ablation recovered 99·9% of cells from PTFE surfaces. The high recovery rate achieved by this technique, along with the fact that cells were able to retain membrane integrity and cultivability, indicate that this device is suitable for the gentle recovery of viable L. monocytogenes biofilm cells. This work presents a highly efficient technique to remove, collect and quantify L. monocytogenes from surfaces commonly used in the food industry, which can thus serve as an important aid in verifying cleaning and sanitation as well as in reducing the likelihood of cross-contamination events. © 2015 The Society for Applied Microbiology.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-01-20
... DEPARTMENT OF COMMERCE International Trade Administration [A-588-707] Granular Polytetrafluoroethylene Resin From Japan: Final Results of Sunset Review and Revocation of Antidumping Duty Order AGENCY.... As a result, in accordance with 19 CFR 351.218(d)(1)(iii)(A), the Department determined that no...
21 CFR 878.5035 - Nonabsorbable expanded polytetrafluoroethylene surgical suture.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Nonabsorbable expanded polytetrafluoroethylene surgical suture. 878.5035 Section 878.5035 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF...; Guidance for Industry and FDA.” See § 878.1(e) for the availability of this guidance document. [65 FR 20735...
Yatmaz, H Cengiz; Dizge, Nadir; Kurt, Merve Sezen
2017-11-01
In this study, the degradation of azo dye solutions (Reactive Red 180 and Reactive Orange 16) of textile industry wastewater was investigated for using innovative hybrid process of photocatalytic and membrane distillation (MD) processes. Photocatalytic oxidation was conducted with semiconductor catalysts (ZnO and TiO2) and their mixture under UVA and UVC irradiation. More effective results were obtained under UVA at the initial stages of the reactions for both dye solutions. ZnO and TiO2 catalysts have given similar efficient results, but results with ZnO were better at initial stages. For the next stage, hybrid design of MD and photocatalytic processes was performed sequentially. Initially, the photocatalytic process was conducted for at least 1 h at initial values of 100 mg/L RR-180 dye solutions and 1 g/L ZnO catalyst loading under UVA irradiation and then treated solution was run through the distillation module at different temperatures (30°C and 40°C) and flow rates (210, 425, and 665 mL/min). Three types of membranes (polypropylene, polytetrafluoroethylene, and polyvinylidene fluoride) with different pore sizes (0.45 and 0.22 μm) were used in the module. Increasing temperature on the side of treated solution and decreasing the temperature on the other side has increased the distillate efficiency.
Bulk and contact resistances of gas diffusion layers in proton exchange membrane fuel cells
NASA Astrophysics Data System (ADS)
Ye, Donghao; Gauthier, Eric; Benziger, Jay B.; Pan, Mu
2014-06-01
A multi-electrode probe is employed to distinguish the bulk and contact resistances of the catalyst layer (CL) and the gas diffusion layer (GDL) with the bipolar plate (BPP). Resistances are compared for Vulcan carbon catalyst layers (CL), carbon paper and carbon cloth GDL materials, and GDLs with microporous layers (MPL). The Vulcan carbon catalyst layer bulk resistance is 100 times greater than the bulk resistance of carbon paper GDL (Toray TG-H-120). Carbon cloth (CCWP) has bulk and contact resistances twice those of carbon paper. Compression of the GDL decreases the GDL contact resistance, but has little effect on the bulk resistance. Treatment of the GDL with polytetrafluoroethylene (PTFE) increases the contact resistance, but has little effect on the bulk resistance. A microporous layer (MPL) added to the GDL decreases the contact resistance, but has little effect on the bulk resistance. An equivalent circuit model shows that for channels less than 1 mm wide the contact resistance is the major source of electronic resistance and is about 10% of the total ohmic resistance associated with the membrane electrode assembly.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dursch, Thomas J.; Ciontea, Monica A.; Radke, Clayton J.
2011-12-01
Nucleation and growth of ice in the fibrous gas-diffusion layer (GDL) of a proton-exchange membrane fuel cell (PEMFC) are studied using isothermal differential scanning calorimetry (DSC). Isothermal crystallization rates and pseudo-steady-state nucleation rates are obtained as a function of subcooling from heat-flow and induction-time measurements. Kinetics of ice nucleation and growth are studied at two polytetrafluoroethylene (PTFE) loadings (0 and 10 wt %) in a commercial GDL for temperatures between 240 and 273 K. A nonlinear ice-crystallization rate expression is developed using Johnson–Mehl–Avrami–Kolmogorov (JMAK) theory, in which the heat-transfer-limited growth rate is determined from the moving-boundary Stefan problem. Induction timesmore » follow a Poisson distribution and increase upon addition of PTFE, indicating that nucleation occurs more slowly on a hydrophobic fiber than on a hydrophilic fiber. The determined nucleation rates and induction times follow expected trends from classical nucleation theory. Finally, a validated rate expression is now available for predicting ice-crystallization kinetics in GDLs.« less
Federal Register 2010, 2011, 2012, 2013, 2014
2011-03-09
... Polytetrafluoroethylene Resin From Italy: Final Results of Expedited Sunset Review of the Antidumping Duty Order AGENCY... resin'') from Italy. The Department has conducted an expedited sunset review of this order. As a result... lead to continuation or recurrence of dumping at the margins identified in the Final Results of Review...
Wu, Chin H; Grant, Christopher V; Cook, Gabriel A; Park, Sang Ho; Opella, Stanley J
2009-09-01
A strip-shield inserted between a high inductance double-tuned solenoid coil and the glass tube containing the sample improves the efficiency of probes used for high-field solid-state NMR experiments on lossy aqueous samples of proteins and other biopolymers. A strip-shield is a coil liner consisting of thin copper strips layered on a PTFE (polytetrafluoroethylene) insulator. With lossy samples, the shift in tuning frequency is smaller, the reduction in Q, and RF-induced heating are all significantly reduced when the strip-shield is present. The performance of 800MHz (1)H/(15)N and (1)H/(13)C double-resonance probes is demonstrated on aqueous samples of membrane proteins in phospholipid bilayers.
NASA Astrophysics Data System (ADS)
Cholid Djunaidi, Muhammad; Lusiana, Retno A.; Rahayu, Maya D.
2017-06-01
Chromium metal(VI) is a valuable metal but in contrary has high toxicity, so the separation and recovery from waste are very important. One method that can be used for the separation and recovery of chromium (VI) is a Supported Liquid Membrane (SLM). SLM system contains of three main components: a supporting membrane, organic solvents and carrier compounds. The supported Membrane used in this research is Polytetrafluoroethylene (PTFE), organic solvent is kerosene, and the carrier compound used is aliquat 336. The supported liquid membrane is placed between two phases, namely, feed phase as the source of analyte (Cr(VI)) and the receiving phase as the result of separation. Feed phase is the electroplating waste which contains of chromium metal with pH variation about 4, 6 and 9. Whereas the receiving phase are the solution of HCl, NaOH, HCl-NaCl and NaOH-NaCl with pH variation about 1, 3, 5 and 7. The efficiency separation is determined by measurement of chromium in the feed and the receiving phase using AAS (Atomic Absorption Spectrophotometry). The experiment results show that transport of Chrom (VI) by Supported Liquid membrane (SLM) is influenced by pH solution in feed phase and receiving phase as well as NaCl in receiving phase. The highest chromium metal is transported from feed phase about 97,78%, whereas in receiving phase shows about 58,09%. The highest chromium metal transport happens on pH 6 in feed phase, pH 7 in receiving phase with the mixture of NaOH and NaCl using carrier compound aliquat 336.
The Evolution of Transjugular Intrahepatic Portosystemic Shunt: Tips
Fanelli, Fabrizio
2014-01-01
Since Richter's description in the literature in 1989 of the first procedure on human patients, transjugular intrahepatic portosystemic shunt (TIPS) has been worldwide considered as a noninvasive technique to manage portal hypertension complications. TIPS succeeds in lowering the hepatic sinusoidal pressure and in increasing the circulatory flow, thus reducing sodium retention, ascites recurrence, and variceal bleeding. Required several revisions of the shunt TIPS can be performed in case of different conditions such as hepatorenal syndrome, hepatichydrothorax, portal vein thrombosis, and Budd-Chiari syndrome. Most of the previous studies on TIPS procedure were based on the use of bare stents and most patients chose TIPS 2-3 years after traditional treatment, thus making TIPS appear to be not superior to endoscopy in survival rates. Bare stents were associated with higher incidence of shunt failure and consequently patients required several revisions during the follow-up. With the introduction of a dedicated e-PTFE covered stent-graft, these problems were completely solved, No more reinterventions are required with a tremendous improvement of patient's quality of life. One of the main drawbacks of the use of e-PTFE covered stent-graft is higher incidence of hepatic encephalopathy. In those cases refractory to the conventional medical therapy, a shunt reduction must be performed. PMID:27335841
Lou, Chaoyan; Guo, Dandan; Wang, Nani; Wu, Shuchao; Zhang, Peimin; Zhu, Yan
2017-06-02
An online membrane-based distillation (MBD) coupled with ion chromatography (IC) method was proposed for automatic detection of trace fluoride (F - ) in serum and urine samples. The system consisted of a sample vessel, a lab-made membrane module and an ion chromatograph. Hydrophobic polytetrafluoroethylene (PTFE) hollow fiber membrane was used in MBD which was directly performed in serum and urine samples to eliminate the matrix interferences and enrich fluoride, while enabling automation. The determination of fluoride in biological samples was carried out by IC with suppressed conductometric detection. The proposed method feasibly determined trace fluoride in serum and urine matrices with the optimized parameters, such as acid concentration, distillation temperature, and distillation time, etc. Fluoride exhibited satisfactory linearity in the range of 0.01-5.0mg/L with a correlation coefficient of 0.9992. The limit of detection (LOD, S/N=3) and limit of quantification (LOQ, S/N=10) were 0.78μg/L and 2.61μg/L, respectively. The relative standard deviations of peak area and peak height were all less than 5.15%. The developed method was validated for the determination of fluoride in serum and urine with good spiked recoveries ranging between 97.1-101.9%. This method also can be proposed as a suitable alternative for the analysis of fluoride in other complex biological samples. Copyright © 2017. Published by Elsevier B.V.
Diffusely reflecting paints including polytetrafluoroethylene and method of manufacture
NASA Technical Reports Server (NTRS)
Schutt, J. B.; Shai, M. C. (Inventor)
1985-01-01
The invention pertains to a high diffuse, reflective paint comprising an alcohol soluble binder, polytetrafluoroethylene (TFE) and an alcohol for coating a substrate and forming an optical reference with a superior Lambertian characteristic. A method for making the paint by first mixing the biner and alcohol, and thereafter by mixing in outgassed TFE is described. A wetting agent may be employed to aid the mixing process.
NASA Astrophysics Data System (ADS)
Cho, Yong Ki; Park, Daewon; Kim, Hoonbae; Lee, Hyerim; Park, Heonyong; Kim, Hong Ja; Jung, Donggeun
2014-03-01
Bioactive surface modification can be used in a variety of medical polymeric materials in the fields of biochips and biosensors, artificial membranes, and vascular grafts. In this study, the surface modification of the inner walls of poly-tetra-fluoro-ethylene (PTFE) tubing was carried out to improve vascular grafts, which are made of biocompatible material for the human body in the medical field. Focus was centered on the cell attachment of the inner wall of the PTFE by sequential processes of hydrogen plasma treatment, hydrocarbon deposition, and reactive plasma treatment on the PFTE surface using micro plasma discharge. Micro plasma was generated by a medium-frequency alternating current high-voltage generator. The preliminary modification of PTFE was conducted by a plasma of hydrogen and argon gases. The hydrocarbon thin film was deposited on modified PTFE with a mixture of acetylene and argon gases. The reactive plasma treatment using oxygen plasma was done to give biocompatible functionality to the inner wall surface. The hydrophobic surface of bare PTFE is made hydrophilic by the reactive plasma treatment due to the formation of carbonyl groups on the surface. The reactive treatment could lead to improved attachment of smooth muscle cells (SMCs) on the modified PTFE tubing. Fourier transform infrared absorption spectroscopy, X-ray photoelectron spectroscopy, scanning electron microscopy, and water contact angle measurement were used for the analysis of the surface modification. The SMC-attached PTFE tube developed will be applicable to in vitro human vasculature-mimetic model systems, and to medical vascular grafts.
Guided bone regeneration in the treatment of periimplantitis.
Persson, L G; Ericsson, I; Berglundh, T; Lindhe, J
1996-12-01
The objective of the present experiment was to study the soft and hard tissue healing following treatment of experimentally induced periimplantitis. 5 labrador dogs about 1-year old were used. The mandibular right and left 1st molars, 4th and 3rd premolars were removed, titanium fixtures (Brånemark System) were installed, and standard abutments were connected in a 2nd stage procedure. After 3 months experimental periimplantitis was induced by the placement of cotton floss ligatures in a submarginal position. 6 weeks later the ligatures were removed. 1 month after ligature removal, an antibiotic regimen was initiated. During a 3-week period, each dog was given tablets of amoxicillin and metronidazole. In the left side of the mandible, buccal and lingual mucoperiosteal flaps were elevated and granulation tissue within the bone craters curetted. The abutments were removed. The exposed outer surfaces and the internal part of the fixtures were carefully cleaned with a detergent (delmopinol HC1). An e-PTFE membrane was placed over each fixture and adjusted to cover the bone crater. New cover screws were fitted through the membranes to the cleaned fixtures. The implants were submerged and the flaps sutured. In the right side of the mandible no local treatment was performed. The dogs were sacrificed after 4 months and biopsies prepared for histological examination. The findings indicated that treatment of a periimplantitis lesion, including comprehensive systemic antimicrobial therapy and cleaning of submerged implants resulted in (i) the elimination of the inflammatory process in the periimplant tissues and (ii) the establishment of a dense connective tissue capsule in direct contact with the previously exposed surface of the implant system. It was also observed that (iii) new bone was frequently laid down on the pristine cover screws.
Bakhshalian, Neema; Freire, Marcelo; Min, Seiko; Wu, Ivy; Zadeh, Homayoun H
A total of 68 extraction sockets were grafted with anorganic bovine bone mineral and covered by dense polytetrafluoroethylene membrane. Quantitative analysis of three-dimensional microcomputed tomography imaging of core samples retrieved after a mean of 21.0 ± 14.2 weeks revealed 40.1% bone volume fraction (bone volume [BV]/total volume [TV]) and 12% residual graft. Evidence of de novo bone formation was observed in the form of discrete islands of newly formed bone in direct apposition to graft particles, separated from parent bone. Anterior sockets exhibited a significantly higher percentage of residual graft compared to premolar sockets (P = .05). The BV/TV and percentage of residual graft correlated well with histomorphometric analysis of the same sites, but not with implant outcomes.
Covered Stent Grafts for Acquired Arterial Venous Fistulas: A Case Series.
Sarac, Timur P; Vargas, Lina; Kashyap, Vikram; Cardella, Jonathan; Chaar, Cassius Ochoa
2018-01-01
Stent grafts have become the preferred method for treating abdominal aortic aneurysms (AAAs) but also have utility in treating other vasculopathies. In 2005, peripheral stent grafts were approved for treating superficial femoral artery occlusive disease. This report describes our experience using covered stent grafts to treat acquired arterial venous fistulae (aAVF). We reviewed the records of patients treated for aAVF with covered stent grafts. Eleven patients had 12 limbs treated with a stent graft. The data collected included presenting symptoms, mechanism of injury, vessel location, stent graft used for therapy, and patency. Eleven patients underwent successful treatment of 12 aAVF with a peripheral stent grafts. The average age was 55.6 (18-87), and there were 4 women and 7 men. The mechanisms of injuries were heart catheterization in 5 patients, penetrating trauma in 3 patients, and orthopedic injury in 3 patients. Five of the patients had concurrent pseudoaneurysms. Self-expanding expanded polytetrafluoroethelene (ePTFE) stent grafts were used in 8 patients, and balloon-expandable ePTFE stent grafts were used in 3 patients. Primary patency at 2 years is 100%, with all patients having significant relief of symptoms. Peripheral stent grafts are a useful tool for treating aAVF, with excellent patency. They provide a valuable minimally invasive approach to this disease. Copyright © 2017 Elsevier Inc. All rights reserved.
Illuminati, Giulio; Calio', Francesco G; D'Urso, Antonio; Ceccanei, Gianluca; Pacilè, Maria Antonietta
2009-01-01
We report on a 58-year-old male who presented with an enlarging cervical hematoma 3 months following carotid endarterectomy with Dacron patch repair, due to septic disruption of the Dacron patch secondary to presumed infection. The essential features of this case are the control of the proximal common carotid artery gained through a median sternotomy, because the patient was markedly obese with minimal thyromental distance, and the treatment consisting of in situ polytetrafluoroethylene bypass grafting, due to the absence of a suitable autogenous saphenous vein. Median sternotomy is rarely required in case of reintervention for septic false aneurysms and hematomas following carotid endarterectomy but should be considered whenever difficult control of the common carotid artery, when entering the previous cervicotomy, is anticipated. In situ polytetrafluoroethylene grafting can be considered if autogenous vein material is lacking.
Evaluation of tissue interactions with mechanical elements of a transscleral drug delivery device.
Cohen, Sarah J; Chan, Robison V Paul; Keegan, Mark; Andreoli, Christopher M; Borenstein, Jeffrey T; Miller, Joan W; Gragoudas, Evangelos S
2012-03-12
The goal of this work was to evaluate tissue-device interactions due to implantation of a mechanically operated drug delivery system onto the posterior sclera. Two test devices were designed and fabricated to model elements of the drug delivery device-one containing a free-spinning ball bearing and the other encasing two articulating gears. Openings in the base of test devices modeled ports for drug passage from device to sclera. Porous poly(tetrafluoroethylene) (PTFE) membranes were attached to half of the gear devices to minimize tissue ingrowth through these ports. Test devices were sutured onto rabbit eyes for 10 weeks. Tissue-device interactions were evaluated histologically and mechanically after removal to determine effects on device function and changes in surrounding tissue. Test devices were generally well-tolerated during residence in the animal. All devices encouraged fibrous tissue formation between the sclera and the device, fibrous tissue encapsulation and invasion around the device, and inflammation of the conjunctiva. Gear devices encouraged significantly greater inflammation in all cases and a larger rate of tissue ingrowth. PTFE membranes prevented tissue invasion through the covered drug ports, though tissue migrated in through other smaller openings. The torque required to turn the mechanical elements increased over 1000 times for gear devices, but only on the order of 100 times for membrane-covered gear devices and less than 100 times for ball bearing devices. Maintaining a lower device profile, minimizing microscale motion on the eye surface and covering drug ports with a porous membrane may minimize inflammation, decreasing the risk of damage to surrounding tissues and minimizing disruption of device operation.
Meecham, Lewis; Fisher, Owain; Kirby, George; Evans, Richard; Buxton, Pauline; Legge, Jocelyn; Rajagopalan, Sriram; Asquith, John; Pherwani, Arun
2016-10-01
We present a case of external iliac vein patch venoplasty to accommodate rescue vascular access via a polytetrafluoroethylene loop arteriovenous fistula graft (AVG) for a patient with multiple central venous stenoses. A 35-year-old female with anti-glomerular basement membrane antibody disease required rescue vascular access for hemodialysis. Repeated occlusion and/or thrombosis of long-term central venous access cannulae, to facilitate dialysis, had caused stenosis of brachiocephalic veins: right external iliac vein and occlusion of the left common iliac vein. A previous right brachiobasilic fistula had occluded within 1 year. No other upper limb options for arteriovenous fistula (AVF) were available. A right external iliac vein bovine patch angioplasty concurrently with a polytetrafluoroethylene AV graft between common femoral artery and common femoral vein was performed to restore venous patency and allow rescue dialysis access. At 3-year follow-up, the fistula remains widely patent with 2 L/min flow rates and no recurrent stenosis to the treated iliac vein. She has not required any further surgical or interventional radiological procedures to maintain fistula or central venous patency. Central venous stenosis or occlusion is common for patients requiring dialysis, especially those with multiple previous long-term central venous cannulations. If restriction of outflow is present, AVF may fail. Venous patch angioplasty in these cases is a successful technique, allowing AVF formation and long-term patency. Central venous stenosis can be treated successfully with patch venoplasty to accommodate AVF/AVG formation for rescue vascular access; this is a potentially lifesaving intervention for patients requiring dialysis. Copyright © 2016 Elsevier Inc. All rights reserved.
Airborne nanoparticle concentrations in the manufacturing of polytetrafluoroethylene (PTFE) apparel.
Vosburgh, Donna J H; Boysen, Dane A; Oleson, Jacob J; Peters, Thomas M
2011-03-01
One form of waterproof, breathable apparel is manufactured from polytetrafluoroethylene (PTFE) membrane laminated fabric using a specific process to seal seams that have been sewn with traditional techniques. The sealing process involves applying waterproof tape to the seam by feeding the seam through two rollers while applying hot air (600 °C). This study addressed the potential for exposure to particulate matter from this sealing process by characterizing airborne particles in a facility that produces more than 1000 lightweight PTFE rain jackets per day. Aerosol concentrations throughout the facility were mapped, breathing zone concentrations were measured, and hoods used to ventilate the seam sealing operation were evaluated. The geometric mean (GM) particle number concentrations were substantially greater in the sewing and sealing areas (67,000 and 188,000 particles cm⁻³)) compared with that measured in the office area (12,100 particles cm⁻³). Respirable mass concentrations were negligible throughout the facility (GM = 0.002 mg m⁻³) in the sewing and sealing areas). The particles exiting the final discharge of the facility's ventilation system were dominated by nanoparticles (number median diameter = 25 nm; geometric standard deviation of 1.39). The breathing zone particle number concentrations of the workers who sealed the sewn seams were highly variable and significantly greater when sealing seams than when conducting other tasks (p < 0.0001). The sealing workers' breathing zone concentrations ranged from 147,000 particles cm⁻³ to 798,000 particles cm⁻³, and their seam responsibility significantly influenced their breathing zone concentrations (p = 0.03). The finding that particle number concentrations were approximately equal outside the hood and inside the local exhaust duct indicated poor effectiveness of the canopy hoods used to ventilate sealing operations.
Airborne Nanoparticle Concentrations in the Manufacturing of Polytetrafluoroethylene (PTFE) Apparel
Vosburgh, Donna J.H.; Boysen, Dane A.; Oleson, Jacob J.; Peters, Thomas M.
2016-01-01
One form of waterproof, breathable apparel is manufactured from polytetrafluoroethylene (PTFE) membrane laminated fabric, using a specific process to seal seams that have been sewn with traditional techniques. The sealing process involves applying waterproof tape to the seam by feeding the seam through two rollers while applying hot air (600°C). This study addressed the potential for exposure to particulate matter from this sealing process, by characterizing airborne particles in a facility that produces over 1,000 lightweight PTFE rain jackets per day. Aerosol concentrations throughout the facility were mapped, breathing zone concentrations were measured, and hoods used to ventilate the seam sealing operation were evaluated. The geometric mean (GM) particle number concentrations were substantially greater in the sewing and sealing areas (67,000 and 188,000 particles cm−3) compared to that measured in the office area (12,100 particles cm−3). Respirable mass concentrations were negligible throughout the facility (GM=0.002 mg m−3 in the sewing and sealing areas). The particles exiting the final discharge of the facility's ventilation system were dominated by nanoparticles (number median diameter = 25 nm; geometric standard deviation of 1.39). The breathing zone particle number concentrations of the workers who sealed the sewn seams were highly variable and significantly greater when sealing seams than when conducting other tasks (p<0.0001). The sealing workers’ breathing zone concentrations ranged from 147,000 particles cm−3 to 798,000 particles cm−3, and their seam responsibility significantly influenced their breathing zone concentrations (p=0.03). The finding that particle number concentrations were approximately equal outside the hood and inside the local exhaust duct indicated poor effectiveness of the canopy hoods used to ventilate sealing operations. PMID:21347955
Zhong, Nianbing; Liao, Qiang; Zhu, Xun; Chen, Rong
2014-04-15
A new simple fiber-optic evanescent wave sensor was created to accurately monitor the growth and hydrogen production performance of biofilms. The proposed sensor consists of two probes (i.e., a sensor and reference probe), using the etched fibers with an appropriate surface roughness to improve its sensitivity. The sensor probe measures the biofilm growth and change of liquid-phase concentration inside the biofilm. The reference probe is coated with a hydrophilic polytetrafluoroethylene membrane to separate the liquids from photosynthetic bacteria Rhodopseudomonas palustris CQK 01 and to measure the liquid concentration. We also developed a model to demonstrate the accuracy of the measurement. The biofilm measurement was calibrated using an Olympus microscope. A linear relationship was obtained for the biofilm thickness range from 0 to 120 μm with a synthetic medium under continuous supply to the bioreactor. The highest level of hydrogen production rate occurred at a thickness of 115 μm.
Improved Cathode Structure for a Direct Methanol Fuel Cell
NASA Technical Reports Server (NTRS)
Valdez, Thomas; Narayanan, Sekharipuram
2005-01-01
An improved cathode structure on a membrane/electrode assembly has been developed for a direct methanol fuel cell, in a continuing effort to realize practical power systems containing such fuel cells. This cathode structure is intended particularly to afford better cell performance at a low airflow rate. A membrane/electrode assembly of the type for which the improved cathode structure was developed (see Figure 1) is fabricated in a process that includes brush painting and spray coating of catalyst layers onto a polymer-electrolyte membrane and onto gas-diffusion backings that also act as current collectors. The aforementioned layers are then dried and hot-pressed together. When completed, the membrane/electrode assembly contains (1) an anode containing a fine metal black of Pt/Ru alloy, (2) a membrane made of Nafion 117 or equivalent (a perfluorosulfonic acid-based hydrophilic, proton-conducting ion-exchange polymer), (3) a cathode structure (in the present case, the improved cathode structure described below), and (4) the electrically conductive gas-diffusion backing layers, which are made of Toray 060(TradeMark)(or equivalent) carbon paper containing between 5 and 6 weight percent of poly(tetrafluoroethylene). The need for an improved cathode structure arises for the following reasons: In the design and operation of a fuel-cell power system, the airflow rate is a critical parameter that determines the overall efficiency, cell voltage, and power density. It is desirable to operate at a low airflow rate in order to obtain thermal and water balance and to minimize the size and mass of the system. The performances of membrane/electrode assemblies of prior design are limited at low airflow rates. Methanol crossover increases the required airflow rate. Hence, one way to reduce the required airflow rate is to reduce the effect of methanol crossover. Improvement of the cathode structure - in particular, addition of hydrophobic particles to the cathode - has been demonstrated to mitigate the effects of crossover and decrease the airflow required.
Bao, James J; Liu, Xiaojing; Zhang, Yong; Li, Youxin
2014-09-15
This paper describes the development of a novel high-throughput hollow fiber membrane solvent microextraction technique for the simultaneous measurement of the octanol/water distribution coefficient (logD) for organic compounds such as drugs. The method is based on a designed system, which consists of a 96-well plate modified with 96 hollow fiber membrane tubes and a matching lid with 96 center holes and 96 side holes distributing in 96 grids. Each center hole was glued with a sealed on one end hollow fiber membrane tube, which is used to separate the aqueous phase from the octanol phase. A needle, such as microsyringe or automatic sampler, can be directly inserted into the membrane tube to deposit octanol as the accepted phase or take out the mixture of the octanol and the drug. Each side hole is filled with aqueous phase and could freely take in/out solvent as the donor phase from the outside of the hollow fiber membranes. The logD can be calculated by measuring the drug concentration in each phase after extraction equilibrium. After a comprehensive comparison, the polytetrafluoroethylene hollow fiber with the thickness of 210 μm, an extraction time of 300 min, a temperature of 25 °C and atmospheric pressure without stirring are selected for the high throughput measurement. The correlation coefficient of the linear fit of the logD values of five drugs determined by our system to reference values is 0.9954, showed a nice accurate. The -8.9% intra-day and -4.4% inter-day precision of logD for metronidazole indicates a good precision. In addition, the logD values of eight drugs were simultaneously and successfully measured, which indicated that the 96 throughput measure method of logD value was accurate, precise, reliable and useful for high throughput screening. Copyright © 2014 Elsevier B.V. All rights reserved.
Automated catalyst processing for cloud electrode fabrication for fuel cells
Goller, Glen J.; Breault, Richard D.
1980-01-01
A process for making dry carbon/polytetrafluoroethylene floc material, particularly useful in the manufacture of fuel cell electrodes, comprises of the steps of floccing a co-suspension of carbon particles and polytetrafluoroethylene particles, filtering excess liquids from the co-suspension, molding pellet shapes from the remaining wet floc solids without using significant pressure during the molding, drying the wet floc pellet shapes within the mold at temperatures no greater than about 150.degree. F., and removing the dry pellets from the mold.
Phase dependent fracture and damage evolution of polytetrafluoroethylene (PTFE)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Brown, E. N.; Rae, P.; Orler, E. B.
2004-01-01
Compared with other polymers, polytetrafluoroethylene (PTFE) presents several advantages for load-bearing structural components including higher strength at elevated temperatures and higher toughness at lowered temperatures. Failure sensitive applications of PTFE include surgical implants, aerospace components, and chemical barriers. Polytetrafluoroethylene is semicrystalline in nature with their linear chains forming complicated phases near room temperature and ambient pressure. The presence of three unique phases near room temperature implies that failure during standard operating conditions may be strongly dependent on the phase. This paper presents a comprehensive and systematic study of fracture and damage evolution in PTFE to elicit the effects of temperature-inducedmore » phase on fracture mechanisms. The fracture behavior of PTFE is observed to undergo transitions from brittle-fracture below 19 C to ductile-fracture with crazing and some stable crack growth to plastic flow aver 30 C. The bulk failure properties are correlated to failure mechanisms through fractography and analysis of the crystalline structure.« less
Grenade, Charlotte; Moniotte, Nicolas; Rompen, Eric; Vanheusden, Alain; Mainjot, Amélie; De Pauw-Gillet, Marie-Claire
2016-12-01
In vitro studies about biomaterials biological properties are essential screening tests. Yet cell cultures encounter difficulties related to cell retention on material surface or to the observation of both faces of permeable materials. The objective of the present study was to develop a reliable in vitro method to study cell behavior on rigid and flexible/permeable biomaterials elaborating two specific insert-based systems (IBS-R and IBS-F respectively). IBS-R was designed as a specific cylindrical polytetrafluoroethylene (PTFE) system to evaluate attachment, proliferation and morphology of human gingival fibroblasts (HGFs) on grade V titanium and lithium disilicate glass-ceramic discs characteristics of dental prostheses. The number of cells, their covering on discs and their morphology were determined from MTS assays and microscopic fluorescent images after 24, 48 and 72 h. IBS-F was developed as a two components system to study HGFs behavior on guided bone regeneration polyester membranes. The viability and the membrane barrier effect were evaluated by metabolic MTS assays and by scanning electron microscopy. IBS-R and IBS-F were shown to promote (1) easy and rapid handling; (2) cell retention on biomaterial surface; (3) accurate evaluation of the cellular proliferation, spreading and viability; (4) use of non-toxic material. Moreover IBS-F allowed the study of the cell migration through degradable membranes, with an access to both faces of the biomaterial and to the bottom of culture wells for medium changing.
Mofidi, Zahra; Norouzi, Parviz; Sajadian, Masumeh; Ganjali, Mohammad Reza
2018-04-01
A novel, simple, and inexpensive analytical technique based on flat sheet supported liquid membrane microextraction coupled with fast Fourier transform stripping cyclic voltammetry on a reduced graphene oxide carbon paste electrode was used for the extraction and online determination of diclofenac in whole blood. First, diclofenac was extracted from blood samples using a polytetrafluoroethylene membrane impregnated with 1-octanol and then into an acceptor solution, subsequently it was oxidized on a carbon paste electrode modified with reduced graphene oxide nanosheets. The optimal values of the key parameters influencing the method were as follows: scan rate, 6 V/s; stripping potential, 200 mV; stripping time, 5 s; pH of the sample solution, 5; pH of the acceptor solution,7; and extraction time, 240 min. The calibration curves were plotted for the whole blood samples and the method was found to have a good linearity within the range of 1-25 μg/mL with a determination coefficient of 0.99. The limits of detection and quantification were 0.1 and 1.0 μg/mL, respectively. Using this coupled method, the extraction and determination were merged into one step. Accordingly, the speed of detection for sensitive determination of diclofenac in complex samples, such as blood, increased considerably. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
A New Strategy to Refine Crude Indian Sardine Oil.
Charanyaa, S; Belur, Prasanna D; Regupathi, I
2017-05-01
Current work aims to develop a refining process for removing phospholipids, free fatty acids (FFA), and metal ions without affecting n-3 polyunsaturated fatty acid (n-3 PUFA) esters present in the crude Indian sardine oil. Sardine oil was subjected to degumming with various acids (orthophosphoric acid, acetic acid, and lactic acid), conventional and membrane assisted deacidification using various solvents (methanol, ethanol, propanol and butanol) and bleaching with bleaching agents (GAC, activated earth and bentonite) and all the process parameters were further optimized. Degumming with 5%(w/w) ortho phosphoric acid, two stage solvent extraction with methanol at 1:1 (w/w) in each stage and bleaching with 3% (w/w) activated charcoal loading, at 80ºC for 10 minutes resulted in the reduction of phospholipid content to 5.66 ppm from 612.66 ppm, FFA to 0.56% from 5.64% with the complete removal of iron and mercury. Under these conditions, the obtained bleached oil showed an enhancement of n-3 PUFA from 16.39 % (11.19 Eicosapentaenoic acid (EPA) + 5.20 Docosahexaenoic acid (DHA)) to 17.91 % (11.81 EPA + 6.1 DHA). Replacing conventional solvent extraction with membrane deacidification using microporous, hydrophobic polytetrafluoroethylene membrane (PTFE), resulted in a lesser solvent residue (0.25% (w/w)) in the deacidified oil. In view of lack of reports on refining of n-3 PUFA rich marine oils without concomitant loss of n-3 PUFA, this report is significant.
Evaluation of Tissue Interactions with Mechanical Elements of a Transscleral Drug Delivery Device
Cohen, Sarah J.; Chan, Robison V. Paul; Keegan, Mark; Andreoli, Christopher M.; Borenstein, Jeffrey T.; Miller, Joan W.; Gragoudas, Evangelos S.
2012-01-01
The goal of this work was to evaluate tissue-device interactions due to implantation of a mechanically operated drug delivery system onto the posterior sclera. Two test devices were designed and fabricated to model elements of the drug delivery device—one containing a free-spinning ball bearing and the other encasing two articulating gears. Openings in the base of test devices modeled ports for drug passage from device to sclera. Porous poly(tetrafluoroethylene) (PTFE) membranes were attached to half of the gear devices to minimize tissue ingrowth through these ports. Test devices were sutured onto rabbit eyes for 10 weeks. Tissue-device interactions were evaluated histologically and mechanically after removal to determine effects on device function and changes in surrounding tissue. Test devices were generally well-tolerated during residence in the animal. All devices encouraged fibrous tissue formation between the sclera and the device, fibrous tissue encapsulation and invasion around the device, and inflammation of the conjunctiva. Gear devices encouraged significantly greater inflammation in all cases and a larger rate of tissue ingrowth. PTFE membranes prevented tissue invasion through the covered drug ports, though tissue migrated in through other smaller openings. The torque required to turn the mechanical elements increased over 1000 times for gear devices, but only on the order of 100 times for membrane-covered gear devices and less than 100 times for ball bearing devices. Maintaining a lower device profile, minimizing microscale motion on the eye surface and covering drug ports with a porous membrane may minimize inflammation, decreasing the risk of damage to surrounding tissues and minimizing disruption of device operation. PMID:24300189
Lead-free precussion primer mixes based on metastable interstitial composite (MIC) technology
Dixon, George P.; Martin, Joe A.; Thompson, Don
1998-01-01
A lead-free percussion primer composition and a percussion cup containing e composition. The lead-free percussion primer composition is comprised of a mixture of about 45 wt % aluminum powder having an outer coating of aluminum oxide and molybdenum trioxide powder or a mixture of about 50 wt % aluminum powder having an outer coating of aluminum oxide and polytetrafluoroethylene powder. The aluminum powder, molybdenum trioxide powder and polytetrafluoroethylene powder has a particle size of 0.1 .mu.m or less, more preferably a particle size of from about 200-500 angstroms.
NASA Astrophysics Data System (ADS)
Kitahara, Tatsumi; Nakajima, Hironori; Okamura, Kosuke
2015-06-01
Gas diffusion layers (GDLs) coated with a hydrophobic microporous layer (MPL) composed of carbon black and polytetrafluoroethylene (PTFE) have been commonly used to improve the water management characteristics of polymer electrolyte fuel cells (PEFCs). However, the hydrophobic MPL coated GDL designed to prevent dehydration of the membrane under low humidity conditions is generally inferior at reducing flooding under high humidity conditions. It is therefore important to develop a robust MPL coated GDL that can enhance the PEFC performance regardless of the humidity conditions. In the present study, a GDL coated with an MPL containing hydrophilic carbon nanotubes (CNTs) was developed. The less hydrophobic pores incorporating CNTs are effective at conserving the membrane humidity under low humidity conditions. The MPL with CNTs is also effective at expelling excess water from the catalyst layer while maintaining oxygen flow pathways from the GDL substrate, allowing the mean flow pore diameter to be decreased to 2 μm without reducing the ability of the MPL to prevent flooding under high humidity conditions. An MPL coated GDL with a CNT content of 4 mass% exhibits significantly higher performance under both low and high humidity conditions than a hydrophobic MPL coated GDL.
NASA Astrophysics Data System (ADS)
Wang, Shunzhong; Li, Xiaohui; Wan, Zhaohui; Chen, Yanan; Tan, Jinting; Pan, Mu
2018-03-01
Oxygen transport resistance (OTR) is a critical factor influencing the performance of proton exchange membrane fuel cells (PEMFCs). In this paper, an effective method to reduce the OTR of catalyst layers (CLs) by introducing a hydrophobic additive into traditional CLs is proposed. A low-molecular-weight polytetrafluoroethylene (PTFE) is selected for its feasibility to prepare an emulsion, which is mixed with a traditional catalyst ink to successfully fabricate the CL with PTFE of 10 wt%. The PTFE film exists in the mesopores between the carbon particles. The limiting current of the hydrophobic CL was almost 4000 mA/cm2, which is 500 mA/cm2 higher than that of the traditional CL. PTFE reduces the OTR of the CL in the dry region by as much as 24 s/m compared to the traditional CL and expands the dry region from 2000 mA/cm2 in the traditional CL to 2500 mA/cm2. Furthermore, the CL with the hydrophobic agent can improve the oxygen transport in the wet region (>2000 mA/cm2) more effectively than that in the dry region. All these results indicate that the CL with the hydrophobic agent shows a superior performance in terms of optimizing water management and effectively reduces the OTR in PEMFCs.
Shlyonsky, Vadim; Dupuis, Freddy; Gall, David
2014-01-01
Understanding the electrical biophysical properties of the cell membrane can be difficult for neuroscience students as it relies solely on lectures of theoretical models without practical hands on experiments. To address this issue, we developed an open-source lipid bilayer amplifier, the OpenPicoAmp, which is appropriate for use in introductory courses in biophysics or neurosciences at the undergraduate level, dealing with the electrical properties of the cell membrane. The amplifier is designed using the common lithographic printed circuit board fabrication process and off-the-shelf electronic components. In addition, we propose a specific design for experimental chambers allowing the insertion of a commercially available polytetrafluoroethylene film. We provide a complete documentation allowing to build the amplifier and the experimental chamber. The students hand-out giving step-by step instructions to perform a recording is also included. Our experimental setup can be used in basic experiments in which students monitor the bilayer formation by capacitance measurement and record unitary currents produced by ionic channels like gramicidin A dimers. Used in combination with a low-cost data acquisition board this system provides a complete solution for hands-on lessons, therefore improving the effectiveness in teaching basic neurosciences or biophysics.
The OpenPicoAmp: An Open-Source Planar Lipid Bilayer Amplifier for Hands-On Learning of Neuroscience
Shlyonsky, Vadim; Dupuis, Freddy; Gall, David
2014-01-01
Understanding the electrical biophysical properties of the cell membrane can be difficult for neuroscience students as it relies solely on lectures of theoretical models without practical hands on experiments. To address this issue, we developed an open-source lipid bilayer amplifier, the OpenPicoAmp, which is appropriate for use in introductory courses in biophysics or neurosciences at the undergraduate level, dealing with the electrical properties of the cell membrane. The amplifier is designed using the common lithographic printed circuit board fabrication process and off-the-shelf electronic components. In addition, we propose a specific design for experimental chambers allowing the insertion of a commercially available polytetrafluoroethylene film. We provide a complete documentation allowing to build the amplifier and the experimental chamber. The students hand-out giving step-by step instructions to perform a recording is also included. Our experimental setup can be used in basic experiments in which students monitor the bilayer formation by capacitance measurement and record unitary currents produced by ionic channels like gramicidin A dimers. Used in combination with a low-cost data acquisition board this system provides a complete solution for hands-on lessons, therefore improving the effectiveness in teaching basic neurosciences or biophysics. PMID:25251830
Management of sepsis involving expanded polytetrafluoroethylene grafts for hemodialysis access.
Bhat, D J; Tellis, V A; Kohlberg, W I; Driscoll, B; Veith, F J
1980-04-01
The incidence and management of infections in 80 polytetrafluoroethylene (PTFE) grafts is reviewed. In a follow-up period of 12 to 30 months, the overall incidence of infection was 19%. In functioning grafts the majority of infections occurred after dialysis puncture or reoperation. With appropriate management, by incision, drainage, and packing of wounds with povidone-iodine solution, it was possible, even in the face of positive blood cultures, to treat four of five localized infections successfully without loss of graft function. Prophylactic antibiotics may be useful in reducing the high incidence of infection associated with secondary operations.
van Lith, R.; Gregory, E.K.; Yang, J.; Kibbe, M.R.; Ameer, G.A.
2014-01-01
Oxidative stress plays an important role in the limited biological compatibility of many biomaterials due to inflammation, as well as in various pathologies including atherosclerosis and restenosis as a result of vascular interventions. Engineering antioxidant properties into a material is therefore a potential avenue to improve the biocompatibility of materials, as well as to locally attenuate oxidative stress-related pathologies. Moreover, biodegradable polymers that have antioxidant properties built into their backbone structure have high relative antioxidant content and may provide prolonged, continuous attenuation of oxidative stress while the polymer or its degradation products are present. In this report, we describe the synthesis of poly(1,8-octanediol-co-citrate-co-ascorbate) (POCA), a citric-acid based biodegradable elastomer with native, intrinsic antioxidant properties. The in vitro antioxidant activity of POCA as well as its effects on vascular cells in vitro and in vivo were studied. Antioxidant properties investigated included scavenging of free radicals, iron chelation and the inhibition of lipid peroxidation. POCA reduced reactive oxygen species generation in cells after an oxidative challenge and protected cells from oxidative stress-induced cell death. Importantly, POCA antioxidant properties remained present upon degradation. Vascular cells cultured on POCA showed high viability, and POCA selectively inhibited smooth muscle cell proliferation, while supporting endothelial cell proliferation. Finally, preliminary data on POCA-coated ePTFE grafts showed reduced intimal hyperplasia when compared to standard ePTFE grafts. This biodegradable, intrinsically antioxidant polymer may be useful for tissue engineering application where oxidative stress is a concern. PMID:24976244
Holton, Luther H; Chung, Thomas; Silverman, Ronald P; Haerian, Hafez; Goldberg, Nelson H; Burrows, Whitney M; Gobin, Andrea; Butler, Charles E
2007-04-01
Synthetic mesh is used for chest wall reconstruction, but infection or exposure can occur and necessitate removal. Human acellular dermal matrix (AlloDerm) has been used to reconstruct musculofascial defects in the trunk with low infection and herniation rates. AlloDerm may have advantages over synthetic mesh for chest wall reconstruction. This study compared outcomes and repair strengths of AlloDerm to expanded polytetrafluoroethylene mesh used for repair of rib cage defects. A 3 x 3-cm, full-thickness, lateral rib cage defect was created in each rabbit and repaired with expanded polytetrafluoroethylene (n = 8) or acellular dermal matrix (n = 9). At 4 weeks, the animals were euthanized and evaluated for lung herniation/dehiscence, strength of adhesions between the implant and intrapleural structures, and breaking strength of the implant materials and the implant-fascia interface. Tissue sections were analyzed with histologic and immunohistochemical staining to evaluate cellular infiltration and vascularization. No herniation or dehiscence occurred with either material. The incidence and strength of adhesions was similar between materials. The mean breaking strength of the AlloDerm-fascia interface (14.5 +/- 8.9 N) was greater than the expanded polytetrafluoroethylene-fascia interface (8.7 +/- 4.4 N; p = 0.027) and similar to the rib-intercostal-rib interface of the contralateral native chest wall (14.0 +/- 5.6 N). The AlloDerm grafts became infiltrated with cells and vascularized after implantation. AlloDerm used for chest wall reconstruction results in greater implant-defect interface strength than expanded polytetrafluoroethylene. The ability of AlloDerm to become vascularized and remodeled by autologous cells and to resist infection may be advantageous for chest wall reconstruction.
Scanning electron microscope study of polytetrafluoroethylene sliding on aluminum single crystals
NASA Technical Reports Server (NTRS)
Brainard, W. A.; Buckley, D. H.
1973-01-01
Friction experiments were conducted in air with polytetrafluoroethylene (PTFE) sliding on aluminum single crystals. Mechanical scoring of the crystals with (110) and (100) orientations was observed with a single pass of the PTFE slider. No scoring was observed on the (111). The degree of scoring of the crystals is related to the hardness, with the hardest surface (111) showing no damage and the softest surface (110) showing the most severe scoring. Scoring is caused by work-hardened pieces of aluminum which, as a consequence of the adhesion between PTFE and aluminum, were pulled out of the bulk and became embedded in the PTFE polymer.
Magnetically driven floating foams for the removal of oil contaminants from water.
Calcagnile, Paola; Fragouli, Despina; Bayer, Ilker S; Anyfantis, George C; Martiradonna, Luigi; Cozzoli, P Davide; Cingolani, Roberto; Athanassiou, Athanassia
2012-06-26
In this study, we present a novel composite material based on commercially available polyurethane foams functionalized with colloidal superparamagnetic iron oxide nanoparticles and submicrometer polytetrafluoroethylene particles, which can efficiently separate oil from water. Untreated foam surfaces are inherently hydrophobic and oleophobic, but they can be rendered water-repellent and oil-absorbing by a solvent-free, electrostatic polytetrafluoroethylene particle deposition technique. It was found that combined functionalization of the polytetrafluoroethylene-treated foam surfaces with colloidal iron oxide nanoparticles significantly increases the speed of oil absorption. Detailed microscopic and wettability studies reveal that the combined effects of the surface morphology and of the chemistry of the functionalized foams greatly affect the oil-absorption dynamics. In particular, nanoparticle capping molecules are found to play a major role in this mechanism. In addition to the water-repellent and oil-absorbing capabilities, the functionalized foams exhibit also magnetic responsivity. Finally, due to their light weight, they float easily on water. Hence, by simply moving them around oil-polluted waters using a magnet, they can absorb the floating oil from the polluted regions, thereby purifying the water underneath. This low-cost process can easily be scaled up to clean large-area oil spills in water.
Long-Term Tissue Culture of Adult Brain and Spleen Slices on Nanostructured Scaffolds.
Kallendrusch, Sonja; Merz, Felicitas; Bechmann, Ingo; Mayr, Stefan G; Zink, Mareike
2017-05-01
Long-term tissue culture of adult mammalian organs is a highly promising approach to bridge the gap between single cell cultures and animal experiments, and bears the potential to reduce in vivo studies. Novel biomimetic materials open up new possibilities to maintain the complex tissue structure in vitro; however, survival times of adult tissues ex vivo are still limited to a few days with established state-of-the-art techniques. Here, it is demonstrated that TiO 2 nanotube scaffolds with specific tissue-tailored characteristics can serve as superior substrates for long-term adult brain and spleen tissue culture. High viability of the explants for at least two weeks is achieved and compared to tissues cultured on standard polytetrafluoroethylene (PTFE) membranes. Histological and immunohistochemical staining and live imaging are used to investigate tissue condition after 5 and 14 d in vitro, while environmental scanning electron microscopy qualifies the interaction with the underlying scaffold. In contrast to tissues cultured on PTFE membranes, enhanced tissue morphology is detected in spleen slices, as well as minor cell death in neuronal tissue, both cultured on nanotube scaffolds. This novel biomimetic tissue model will prove to be useful to address fundamental biological and medical questions from tissue regeneration up to tumor progression and therapeutic approaches. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Na, Han Kyu; Song, Ho-Young; Kim, Jin Hyoung; Park, Jung-Hoon; Kang, Min Kyoung; Lee, Jongjin; Oh, Se Jin
2013-03-01
To evaluate the clinical efficacy and safety of self-expandable metallic stent (SEMS) placement for malignant oesophageal strictures and their relationship with stent designs. Seven generations of SEMS were used to treat 645 consecutive patients with oesophageal strictures. Logistic regression models were constructed to identify predictive factors associated with complications. Stent placement was technically successful in 641 of 645 patients (99.4%). The clinical success rate was 95.5%. There were 260 (40.3%) complications after stent placement. Due to complications, 68 stents were removed; 66 of 68 stents (97.1%) were removed successfully. Stainless steel (SS) stents (odds ratio [OR] 4.18; 95% confidence interval [CI] 2.10, 8.32) and radiation therapy (RT) before stent placement (OR 4.23; CI 2.02, 8.83) were significantly associated with severe pain. Flared ends (OR 9.63; CI 3.38, 27.43), stricture length <6 cm (OR 2.01; CI 1.13, 3.60), and a stent diameter <18 mm (OR 3.00; CI 1.32, 6.84) were predictive factors of stent migration. Polyurethane membranes were associated with more frequent tumour ingrowth than polytetrafluoroethylene (PTFE) membranes (P = 0.002). Despite the relatively high complication rate, retrievable self-expandable PTFE-covered nitinol stents equipped with a head and a tail appeared to be an effective treatment for malignant oesophageal strictures.
Deeb, George R; Tran, Dan; Carrico, Caroline K; Block, Erin; Laskin, Daniel M; Deeb, Janina Golob
2017-10-01
The tent screw pole technique is one of the methods available for practitioners to perform horizontal ridge augmentation to facilitate dental implant placement. The purpose of this study was to evaluate the efficacy of the tent screw pole technique for horizontal ridge augmentation and to compare the results with those of the tunnel technique and open ridge augmentation. In this retrospective cohort study, 35 patients underwent horizontal ridge augmentation with the tent screw pole technique, a 1:1 ratio of mineralized freeze-dried bone allograft and particulate bovine hydroxyapatite, and a resorbable collagen membrane. The incidence of early wound dehiscence and membrane exposure, the number of courses of antibiotics and postoperative visits required for their management, and the number of sites that subsequently had successful implant placement were recorded. These parameters were compared with those in 21 patients who had undergone horizontal ridge augmentation by the tunnel technique and 31 patients who had been treated using an open procedure and a resorbable polytetrafluoroethylene (PTFE) membrane in the authors' previous study (J Oral Maxillofac Surg 74:1752, 2016). Implant placement rate was similar for all 3 methods (71 to 97%). However, there were significant differences among the 3 surgical techniques for membrane exposure and wound dehiscence (P = .0033), graft loss (P = .0256), courses of antibiotics (P = .0017), and postoperative visits (P = .0043). The PTFE method consistently had the highest rate of complications, whereas the tent screw and tunnel techniques were comparable. All 3 techniques allowed a high rate of implant placement; however, the PTFE technique was consistently associated with increased postoperative complications compared with the other 2 methods. The tent screw technique might be more favorable than the tunnel technique in cases in which the bony deficiency is flat. Copyright © 2017 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.
Improved adhesion of Ni films on X-ray damaged polytetrafluoroethylene
NASA Technical Reports Server (NTRS)
Wheeler, D. R.; Pepper, S. V.
1981-01-01
The considered investigation shows that the adhesion of evaporated Ni on polytetrafluoroethylene (PTFE) is enhanced by irradiating the PTFE surface prior to evaporation. Evidence obtained with the aid of X-ray photoelectron spectroscopy is presented concerning the association of the enhanced adhesion with an interfacial chemical reaction. Evaporated Ni clearly adheres better to the X-ray damaged PTFE surface than to the undamaged surface. There is evidence that the improved adhesion is not related to the Ni-C bond, but rather to the NiF2. A possible mechanism which may be consistent with the data is the formation of a F-Ni-C complex, where C is a member of the polymer chain.
Packing of poly(tetrafluoroethylene) in the liquid state: Molecular dynamics simulation and theory
NASA Astrophysics Data System (ADS)
Tsige, Mesfin; Curro, John G.; Grest, Gary S.
2008-12-01
Molecular dynamics simulations and polymer reference interaction site model theory calculations were carried out on the C48F98 oligomer of poly(tetrafluoroethylene) (PTFE) at 500 and 600 K. The exp-6 force field of Borodin, Smith, and Bedrov, was used in both the simulation and theory. The agreement between theory and simulation was equivalent to earlier studies on polyolefin melts. The intermolecular pair correlation functions of PTFE were shifted to larger distances relative to polyethylene (PE) due to the difference in the van der Waals radii of F and H atoms. A similar shift to lower wave vectors was found in the structure factor of PTFE relative to PE.
Islam, M T; Samsuzzaman, M
2014-01-01
This paper introduces a new configuration of compact, triangular- and diamond-slotted, microstrip-fed, low-profile antenna for C/X band applications on polytetrafluoroethylene glass microfiber reinforced material substrate. The antenna is composed of a rectangular-shaped patch containing eight triangles and two diamond-shaped slots and an elliptical-slotted ground plane. The rectangular-shaped patch is obtained by cutting two diamond slots in the middle of the rectangular patch, six triangular slots on the left and right side of the patch, and two triangular slots on the up and down side of the patch. The slotted radiating patch, the elliptical-slotted ground plane, and the microstrip feed enable the matching bandwidth to be widened. A prototype of the optimized antenna was fabricated on polytetrafluoroethylene glass microfiber reinforced material substrate using LPKF prototyping machine and investigated to validate the proposed design. The simulated results are compared with the measured data, and good agreement is achieved. The proposed antenna offers fractional bandwidths of 13.69% (7.78-8.91 GHz) and 10.35% (9.16-10.19 GHz) where S11 < -10 dB at center frequencies of 8.25 GHz and 9.95 GHz, respectively, and relatively stable gain, good radiation efficiency, and omnidirectional radiation patterns in the matching band.
Active screen cage pulsed dc discharge for implanting copper in polytetrafluoroethylene (PTFE)
NASA Astrophysics Data System (ADS)
Zaka-ul-Islam, Mujahid; Naeem, Muhammad; Shafiq, Muhammad; Sitara; Jabbar Al-Rajab, Abdul; Zakaullah, Muhammad
2017-07-01
Polymers such as polytetrafluoroethylene (PTFE) are widely used in artificial organs where long-term anti-bacterial properties are required to avoid bacterial proliferation. Copper or silver ion implantation on the polymer surface is known as a viable method to generate long-term anti-bacterial properties. Here, we have tested pulsed DC plasma with copper cathodic cage for the PTFE surface treatment. The surface analysis of the treated specimens suggests that the surface, structural properties, crystallinity and chemical structure of the PTFE have been changed, after the plasma treatment. The copper release tests show that copper ions are released from the polymer at a slow rate and quantity of the released copper increases with the plasma treatment time.
NASA Astrophysics Data System (ADS)
Chanda, Debabrata; Hnát, Jaromir; Bystron, Tomas; Paidar, Martin; Bouzek, Karel
2017-04-01
In this work, the Ni-Co spinel oxides are synthesized via different methods and using different calcination temperatures. Properties of the prepared materials are compared. The best route is selected and used to prepare a Ni1+xCo2-xO4 (-1 ≤ x ≤ 1) series of materials in order to investigate their catalytic activity towards the oxygen evolution reaction (OER). The results show that hydroxide preparation yields NiCo2O4 oxide with the highest activity. 325 °C is identified as the optimum calcination temperature. Subsequently, the catalysts are tested in an electrolysis cell. To prepare an anode catalyst layer based on NiCo2O4 catalyst on top of a nickel foam substrate for membrane electrode assembly (MEA) construction, following polymer binders are used: anion-selective quaternized polyphenylene oxide (qPPO), inert polytetrafluoroethylene (PTFE®), and cation-selective Nafion®. qPPO ionomer containing MEA exhibited highest OER activity. The current density obtained using a MEA containing qPPO binder attains a value of 135 mA cm-2 at a cell voltage of 1.85 V. After 7 h chronopotentiometric experiment at a constant current density of 225 mA cm-2, the MEA employing PTFE® binder shows higher stability than the other binders in alkaline water electrolysis at 50 °C. Under similar conditions, stability of the PTFE®-binding MEA is examined for 135 h.
Islam, M. T.; Samsuzzaman, M.
2014-01-01
This paper introduces a new configuration of compact, triangular- and diamond-slotted, microstrip-fed, low-profile antenna for C/X band applications on polytetrafluoroethylene glass microfiber reinforced material substrate. The antenna is composed of a rectangular-shaped patch containing eight triangles and two diamond-shaped slots and an elliptical-slotted ground plane. The rectangular-shaped patch is obtained by cutting two diamond slots in the middle of the rectangular patch, six triangular slots on the left and right side of the patch, and two triangular slots on the up and down side of the patch. The slotted radiating patch, the elliptical-slotted ground plane, and the microstrip feed enable the matching bandwidth to be widened. A prototype of the optimized antenna was fabricated on polytetrafluoroethylene glass microfiber reinforced material substrate using LPKF prototyping machine and investigated to validate the proposed design. The simulated results are compared with the measured data, and good agreement is achieved. The proposed antenna offers fractional bandwidths of 13.69% (7.78–8.91 GHz) and 10.35% (9.16–10.19 GHz) where S11 < −10 dB at center frequencies of 8.25 GHz and 9.95 GHz, respectively, and relatively stable gain, good radiation efficiency, and omnidirectional radiation patterns in the matching band. PMID:24987742
21 CFR 874.3820 - Endolymphatic shunt.
Code of Federal Regulations, 2010 CFR
2010-04-01
...) Identification. An endolymphatic shunt is a device that consists of a tube or sheet intended to be implanted to... made of polytetrafluoroethylene or silicone elastomer. (b) Classification. Class II. ...
21 CFR 874.3820 - Endolymphatic shunt.
Code of Federal Regulations, 2011 CFR
2011-04-01
...) Identification. An endolymphatic shunt is a device that consists of a tube or sheet intended to be implanted to... made of polytetrafluoroethylene or silicone elastomer. (b) Classification. Class II. ...
21 CFR 874.3820 - Endolymphatic shunt.
Code of Federal Regulations, 2014 CFR
2014-04-01
...) Identification. An endolymphatic shunt is a device that consists of a tube or sheet intended to be implanted to... made of polytetrafluoroethylene or silicone elastomer. (b) Classification. Class II. ...
21 CFR 874.3820 - Endolymphatic shunt.
Code of Federal Regulations, 2013 CFR
2013-04-01
...) Identification. An endolymphatic shunt is a device that consists of a tube or sheet intended to be implanted to... made of polytetrafluoroethylene or silicone elastomer. (b) Classification. Class II. ...
21 CFR 874.3820 - Endolymphatic shunt.
Code of Federal Regulations, 2012 CFR
2012-04-01
...) Identification. An endolymphatic shunt is a device that consists of a tube or sheet intended to be implanted to... made of polytetrafluoroethylene or silicone elastomer. (b) Classification. Class II. ...
NASA Technical Reports Server (NTRS)
Ponter, A. B.; Jones, W. R., Jr.; Jansen, R. H.
1994-01-01
Contact angles of water and methylene iodide were measured as a function of UV/O3 treatment time for three polymers: poly(methylmethacrylate) (PMMA), polycarbonate, and polytetrafluoroethylene (PTFE). Surface roughnesses were also measured. Surface free energies were then calculated using relationships developed by Kaelble and Neumann. The surface energy of polycarbonate was found to increase (60 percent) during UV/O3 treatment. However, calculations on PMMA were hampered by the formation of a water soluble surface product. On PTFE surfaces, the UV/O3 treatment etched the surface causing large increases in surface roughness, rendering contact angle measurements impossible. It is concluded that care must be taken in interpreting contact angle measurements and surface energy calculations on UV/O3 treated polymer surfaces.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yamaguchi, Akinobu, E-mail: yamaguti@lasti.u-hyogo.ac.jp, E-mail: utsumi@lasti.u-hyogo.ac.jp; Kido, Hideki; Utsumi, Yuichi, E-mail: yamaguti@lasti.u-hyogo.ac.jp, E-mail: utsumi@lasti.u-hyogo.ac.jp
2016-02-01
We developed a process for micromachining polytetrafluoroethylene (PTFE): anisotropic pyrochemical microetching induced by synchrotron X-ray irradiation. X-ray irradiation was performed at room temperature. Upon heating, the irradiated PTFE substrates exhibited high-precision features. Both the X-ray diffraction peak and Raman signal from the irradiated areas of the substrate decreased with increasing irradiation dose. The etching mechanism is speculated as follows: X-ray irradiation caused chain scission, which decreased the number-average degree of polymerization. The melting temperature of irradiated PTFE decreased as the polymer chain length decreased, enabling the treated regions to melt at a lower temperature. The anisotropic pyrochemical etching process enabledmore » the fabrication of PTFE microstructures with higher precision than simultaneously heating and irradiating the sample.« less
Mizuno, T; Mizukoshi, T; Uechi, M
2013-02-01
Mitral valve repair under cardiopulmonary bypass was performed in three dogs with clinical signs associated with mitral regurgitation that were not controlled by medication. Mitral valve repair comprised circumferential annuloplasty and chordal replacement with expanded polytetrafluoroethylene. One dog died 2 years after surgery because of severe mitral regurgitation resulting from partial circumferential suture detachment. The others survived for over 5 years, but mild mitral valve stenosis persisted in one. The replaced chordae did not rupture in any dog. Mitral valve repair appears to be an effective treatment for mitral regurgitation in dogs. Chordal replacement with expanded polytetrafluoroethylene is a feasible technique, demonstrating long-term durability in dogs. However, mitral annuloplasty techniques need improvement. © 2012 British Small Animal Veterinary Association.
21 CFR 878.5035 - Nonabsorbable expanded polytetrafluoroethylene surgical suture.
Code of Federal Regulations, 2011 CFR
2011-04-01
... HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical..., including cardiovascular surgery. It may be undyed or dyed with an approved color additive and may be...
21 CFR 878.5035 - Nonabsorbable expanded polytetrafluoroethylene surgical suture.
Code of Federal Regulations, 2014 CFR
2014-04-01
... HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical..., including cardiovascular surgery. It may be undyed or dyed with an approved color additive and may be...
21 CFR 878.5035 - Nonabsorbable expanded polytetrafluoroethylene surgical suture.
Code of Federal Regulations, 2012 CFR
2012-04-01
... HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical..., including cardiovascular surgery. It may be undyed or dyed with an approved color additive and may be...
21 CFR 878.5035 - Nonabsorbable expanded polytetrafluoroethylene surgical suture.
Code of Federal Regulations, 2013 CFR
2013-04-01
... HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical..., including cardiovascular surgery. It may be undyed or dyed with an approved color additive and may be...
Almutairi, Azel; Weatherley, Laurence R
2015-09-01
The use of nitrification filters for the removal of ammonium ion from waste-water is an established technology deployed extensively in municipal water treatment, in industrial water treatment and in applications such as fish farming. The process involves the development of immobilized bacterial films on a solid packing support, which is designed to provide a suitable host for the film, and allow supply of oxygen to promote aerobic action. Removal of ammonia and nitrite is increasingly necessary to meet drinking water and discharge standards being applied in the US, Europe and other places. Ion-exchange techniques are also effective for removal of ammonia (as the ammonium ion) from waste water and have the advantage of fast start-up times compared to biological filtration which in some cases may take several weeks to be fully operational. Here we explore the performance of ion exchange columns in which nitrifying bacteria are cultivated, with the goal of a "combined" process involving simultaneous ion-exchange and nitrification, intensified by in-situ aeration with a novel membrane module. There were three experimental goals. Firstly, ion exchange zeolites were characterized and prepared for comparative column breakthrough studies for ammonia removal. Secondly effective in-situ aeration for promotion of nitrifying bacterial growth was studied using a number of different membranes including polyethersulfone (PES), polypropylene (PP), nylon, and polytetra-fluoroethylene (PTFE). Thirdly the breakthrough performance of ion exchange columns filled with zeolite in the presence of aeration and in the presence of nitrifying bacteria was determined to establish the influence of biomass, and aeration upon breakthrough during ammonium ion uptake. The methodology adopted included screening of two types of the naturally occuring zeolite clinoptilolite for effective ammonia removal in continuous ion-exchange columns. Next, the performance of fixed beds of clinoptilolite in the presence of nitrifying bacteria is compared to that in columns in which only ion exchange is occurring. The aeration performance of each of the chosen membranes was compared experimentally using a newly developed membrane support module which is also described. Comparison of ammonia removal in columns equipped with in-situ aeration using each membrane was undertaken and the breakthrough characteristics determined. The results showed that ammonia removal in the presence of the nitrifiers was significantly intensified. Column operation with membrane aeration showed further enhancement of ammonia removal. The greatest enhancement was observed in the case of the polyethersulfone membrane (PES). It is concluded that combined nitrification and ion-exchange is significantly intensified in packed columns by in-situ aeration using a novel membrane module. There is significant potential for extending the ion-exchange cycle time and thus potential cost reduction. Copyright © 2015 Elsevier Ltd. All rights reserved.
Rust-Inhibited Nonreactive Perfluorinated Polymer Greases
Perfluoroalkylpolyether fluids thickened with polytetrafluoroethylene were studied in connection with the development of rust-inhibited chemically...dimethyloctadecylbenzyl ammonium bentonite + sodium nitrate imparts very effective rust-preventive properties to perfluoro polymer grease mixtures. Data are
Panda, Anton; Dyadyura, Kostiantyn; Valíček, Jan; Harničárová, Marta; Zajac, Jozef; Modrák, Vladimír; Pandová, Iveta; Vrábel, Peter; Nováková-Marcinčínová, Ema; Pavelek, Zdeněk
2017-01-01
The results of the investigations into the technological formation of new wear-resistant polymer composites based on polytetrafluoroethylene (PTFE) filled with disperse synthetic and natural compounds are presented. The efficiency of using PTFE composites reinforced with carbon fibers depends on many factors, which influence the significant improvement of physicomechanical characteristics. The results of this research allow stating that interfacial and surface phenomena of the polymer–solid interface and composition play a decisive role in PTFE composites properties. Fillers hinder the relative movement of the PTFE molecules past one another and, in this way, reduce creep or deformation of the parts, reducing the wear rate of parts used in dynamic applications as well as the coefficient of thermal expansion. The necessary structural parameters of such polymer composites are provided by regimes of process equipment. PMID:28772733
Panda, Anton; Dyadyura, Kostiantyn; Valíček, Jan; Harničárová, Marta; Zajac, Jozef; Modrák, Vladimír; Pandová, Iveta; Vrábel, Peter; Nováková-Marcinčínová, Ema; Pavelek, Zdeněk
2017-03-31
The results of the investigations into the technological formation of new wear-resistant polymer composites based on polytetrafluoroethylene (PTFE) filled with disperse synthetic and natural compounds are presented. The efficiency of using PTFE composites reinforced with carbon fibers depends on many factors, which influence the significant improvement of physicomechanical characteristics. The results of this research allow stating that interfacial and surface phenomena of the polymer-solid interface and composition play a decisive role in PTFE composites properties. Fillers hinder the relative movement of the PTFE molecules past one another and, in this way, reduce creep or deformation of the parts, reducing the wear rate of parts used in dynamic applications as well as the coefficient of thermal expansion. The necessary structural parameters of such polymer composites are provided by regimes of process equipment.
The effect of normal load on polytetrafluoroethylene tribology.
Barry, Peter R; Chiu, Patrick Y; Perry, Scott S; Sawyer, W Gregory; Phillpot, Simon R; Sinnott, Susan B
2009-04-08
The tribological behavior of oriented poly(tetrafluoroethylene) (PTFE) sliding surfaces is examined as a function of sliding direction and applied normal load in classical molecular dynamics (MD) simulations. The forces are calculated with the second-generation reactive empirical bond-order potential for short-range interactions, and with a Lennard-Jones potential for long-range interactions. The range of applied normal loads considered is 5-30 nN. The displacement of interfacial atoms from their initial positions during sliding is found to vary by a factor of seven, depending on the relative orientation of the sliding chains. However, within each sliding configuration the magnitude of the interfacial atomic displacements exhibits little dependence on load over the range considered. The predicted friction coefficients are also found to vary with chain orientation and are in excellent quantitative agreement with experimental measurements.
Effect of X-ray flux on polytetrafluoroethylene in X-ray photoelectron spectroscopy
NASA Technical Reports Server (NTRS)
Wheeler, D. R.; Pepper, S. V.
1982-01-01
The effect of the X-ray flux in X-ray photoelectron spectroscopy (STAT) on the constitution of the polytetrafluoroethylene (PTFE) surface has been examined. The radiation dose rate for our specimen was about 10 to the 7th rad/s. The structure, magnitude and binding energy of the C(1s) and F(1s) features of the XPS spectrum and the mass spectrum of gaseous species evolved during irradiation are observed. The strong time dependence of these signals over a period of several hours indicated that the surface constitution of PTFE is greatly affected by this level of radiation dose. The results are consistent with the development of a heavily cross-linked or branched structure in the PTFE surface region and the evolution of short chain fragments into the gas phase.
NASA Astrophysics Data System (ADS)
Qi, Dong; Cheng, Yongzhi; Wang, Xian; Wang, Fang; Li, Bowen; Gong, Rongzhou
2017-12-01
In this paper, a polytetrafluoroethylene (PTFE) top-covered multi-layer composite structure PTFE/H s/(Ge/ZnS)3 (H s represents the surface layer ZnS with various thicknesses) for spectral compatibility is proposed and investigated theoretically and experimentally. A substantial decline of glossiness from over 200 Gs to 74.2 Gs could be realized, due to high roughness and interface reflection of the 800 nm PTFE protection layer. In addition, similar to the structure of H s/(Ge/ZnS)3, the designed structure with a certain color exhibits ultra-low emissivity of average 0.196 at 8-14 µm and highly transparent performance of 96.45% in the radar frequency range of 2-18 GHz. Our design will provide an important reference for the practical applications of the spectral compatible multilayer films.
Grytsenko, Konstantin; Lozovski, Valeri; Strilchuk, Galyna; Schrader, Sigurd
2012-11-07
Nanocomposite films consisting of gold inclusions in the polytetrafluoroethylene (PTFE) matrix were obtained by thermal vacuum deposition. Annealing of the obtained films with different temperatures was used to measure varying of film morphologies. The dependence of optical properties of the films on their morphology was studied. It was established that absorption and profile of the nanocomposite film obtained by thermal vacuum deposition can be changed with annealing owing to the fact that different annealing temperatures lead to different average particle sizes. A method to calculate the optical properties of nanocomposite thin films with inclusions of different sizes was proposed. Thus, comparison of experimental optical spectra with the spectra obtained during the simulation enables estimating average sizes of inclusions. The calculations give the possibility of understanding morphological changes in the structures.
The effect of normal load on polytetrafluoroethylene tribology
NASA Astrophysics Data System (ADS)
Barry, Peter R.; Chiu, Patrick Y.; Perry, Scott S.; Sawyer, W. Gregory; Phillpot, Simon R.; Sinnott, Susan B.
2009-04-01
The tribological behavior of oriented poly(tetrafluoroethylene) (PTFE) sliding surfaces is examined as a function of sliding direction and applied normal load in classical molecular dynamics (MD) simulations. The forces are calculated with the second-generation reactive empirical bond-order potential for short-range interactions, and with a Lennard-Jones potential for long-range interactions. The range of applied normal loads considered is 5-30 nN. The displacement of interfacial atoms from their initial positions during sliding is found to vary by a factor of seven, depending on the relative orientation of the sliding chains. However, within each sliding configuration the magnitude of the interfacial atomic displacements exhibits little dependence on load over the range considered. The predicted friction coefficients are also found to vary with chain orientation and are in excellent quantitative agreement with experimental measurements.
Chadwick, E G; Clarkin, O M; Raghavendra, R; Tanner, D A
2014-01-01
The properties of porous silicon make it a promising material for a host of applications including drug delivery, molecular and cell-based biosensing, and tissue engineering. Porous silicon has previously shown its potential for the controlled release of pharmacological agents and in assisting bone healing. Hydroxyapatite, the principle constituent of bone, allows osteointegration in vivo, due to its chemical and physical similarities to bone. Synthetic hydroxyapatite is currently applied as a surface coating to medical devices and prosthetics, encouraging bone in-growth at their surface and improving osseointegration. This paper examines the potential for the use of an economically produced porous silicon particulate-polytetrafluoroethylene sheet for use as a guided bone regeneration device in periodontal and orthopaedic applications. The particulate sheet is comprised of a series of microparticles in a polytetrafluoroethylene matrix and is shown to produce a stable hydroxyapatite on its surface under simulated physiological conditions. The microstructure of the material is examined both before and after simulated body fluid experiments for a period of 1, 7, 14 and 30 days using Scanning Electron Microscopy. The composition is examined using a combination of Energy Dispersive X-ray Spectroscopy, Thin film X-ray diffraction, Attenuated Total Reflectance-Fourier Transform Infrared Spectroscopy and the uptake/release of constituents at the fluid-solid interface is explored using Inductively Coupled Plasma-Optical Emission Spectroscopy. Microstructural and compositional analysis reveals progressive growth of crystalline, 'bone-like' apatite on the surface of the material, indicating the likelihood of close bony apposition in vivo.
Surgical treatment of pulmonic stenosis in dogs under cardiopulmonary bypass: outcome in nine dogs.
Bristow, P; Sargent, J; Luis Fuentes, V; Brockman, D
2018-01-01
To describe the outcome for nine dogs with pulmonic stenosis treated by open patch grafting using expanded polytetrafluoroethylene under cardiopulmonary bypass. Data were collected from the hospital records of all dogs that had undergone right ventricular outflow tract grafting with an expanded polytetrafluoroethylene patch under cardiopulmonary bypass between 2006 and 2012 for the treatment of pulmonic stenosis. Echocardiographic images were reviewed and the pressure gradient across the right ventricular outflow tract re-measured. Owners of dogs still alive at the time of writing were invited to return to the hospital for reassessment. Nine dogs met the inclusion criteria. Median pressure gradient preoperatively was 118 mmHg, (range 102 to 259 mmHg) reducing to a median of 20 mmHg (range 7 to 53 mmHg) at 48 hours postoperatively and 14 mmHg (range 10 to 70 mmHg), with a median percentage reduction of 89% (range 41 to 94%) at long-term follow-up. Eight of nine dogs survived surgery, with six of nine surviving to hospital discharge. Two dogs were still alive over 6 and 8 years postoperatively. No long-term deaths were believed to be attributable to pulmonic stenosis. Expanded polytetrafluoroethylene patch grafting of the right ventricular outflow tract for treatment of severe pulmonic stenosis in dogs is feasible and can be an effective method to reduce the severity of right ventricular outflow tract obstruction. © 2017 British Small Animal Veterinary Association.
Malavasi, N V; Rodrigues, D B; Chammas, R; Chura-Chambi, R M; Barbuto, J A M; Balduino, K; Nonogaki, S; Morganti, L
2010-01-01
Endostatin (ES) is a potent inhibitor of angiogenesis and tumor growth. Continuous ES delivery of ES improves the efficacy and potency of the antitumoral therapy. The TheraCyte system is a polytetrafluoroethylene (PTFE) semipermeable membrane macroencapsulation system for implantation of genetically engineered cells specially designed for the in vivo delivery of therapeutic proteins, such as ES, which circumvents the problem of limited half-life and variation in circulating levels. In order to enable neovascularization at the tissues adjacent to the devices prior to ES secretion by the cells inside them, we designed a scheme in which empty TheraCyte devices were preimplanted SC into immunodeficient mice. Only after healing (17 days later) were Chinese hamster ovary cells expressing ES injected into the preimplanted devices. In another model for device implantation, the cells expressing ES where loaded into the immunoisolation devices prior to implantation into the animals, and the TheraCyte were then immediately implanted SC into the mice. Throughout the 2-month study, constant high ES levels of up to 3.7 microg/ml were detected in the plasma of the mice preimplanted with the devices, while lower but also constant levels of ES (up to 2.1 microg/ml plasma) were detected in the mice that had received devices preloaded with the ES-expressing cells. Immunohistochemistry using anti-ES antibody showed reaction within the device and outside it, demonstrating that ES, secreted by the confined recombinant cells, permeated through the membrane and reached the surrounding tissues.
De Santis, D; Menchini Fabris, G B; Lotti, J; Palumbo, C; Ferretti, M; Castellani, R; Lotti, T; Zanotti, G; Gelpi, F; Covani, C; Nocini, P F
Collagen Matrix (CM) 10826 is a nanostructured bi-layered collagen membrane obtained from type I and III porcine collagen, which in vitro has shown to have the potential to be a substitute and/or stimulant for soft oral tissue regeneration. The objective of this study was to evaluate the in vivo potential and safety of this membrane for soft tissue regeneration in the early stage of wound healing. Two soft tissue wounds (test and control) were created on the back skin of 5 rabbits (female New Zealand White Rabbits specific pathogen free). All wounds were protected by a special poly-tetra-fluoro-ethylene (PTFE) healing camera. On each rabbit on the test side CM-10826 was used, while on the control side conventional treatment (an autologous pedicle graft) was performed. The healing process was observed clinically after 2 and 6 days, and Magnetic Resonance Imaging (MRI) was performed after this period. After 7 days, animals were sacrificed and specimens were analyzed with light optic microscopy (LM), Transmission Electron Microscopy (TEM) and Scanning Electron Microscopy (SEM). These in vivo trials on rabbits confirmed that CM-10826 is well tolerated, without signs of histological inflammatory reaction and proved to be able to accelerate the spontaneous repair of the skin defect taken as the control. The light-optic and ultra-microscopy of serial biopsies showed that the new matrix is biocompatible and is able to function as a scaffold inducing soft tissue regeneration. In conclusion this study demonstrates that CM-10826 promote early soft tissue regeneration and suggests it is a potential constituent for human autologous keratinocytes seeded derma bioequivalent. It protects the wound from injuries and bacterial contamination accelerating healing process. As a clinical relevance, we consider that the quality of life of patients will be improved avoiding the use of major autologous grafts, reducing the hospitalization time and morbidity.
Foam-filled cushions for sliding trays
NASA Technical Reports Server (NTRS)
Nahin, S. B.; Robb, P. H.
1980-01-01
Polytetrafluoroethylene tube filled with polyurethane foam forms low friction sliding surface that cushions vibrations and absorbs manufacturing tolerances and misalignment. Possible uses include packaging of components for shipping and seals for doors in lockers, cars, and refrigerators.
A flow-through column electrolytic cell for supercritical fluid chromatography.
Yamamoto, Kazuhiro; Ueki, Tatsuya; Higuchi, Naoyuki; Takahashi, Kouji; Kotani, Akira; Hakamata, Hideki
2017-10-01
A novel flow-through column electrolytic cell was proposed as a detector to obtain current signals for supercritical fluid chromatography. The electrochemical cell consisted of two electrodes and its holder, and a working and a counter electrode were fabricated from 192 carbon strings, which were composed of 400 carbon fibers of 10 μm in diameter filled into a heat-shrinkable tube. These electrodes were placed in the center of a holder made from polyether ether ketone blocks and they were separated by polytetrafluoroethylene membrane filters. To evaluate the sensitivity of this cell, a standard solution of ferrocene was injected into the supercritical fluid chromatography system connected to the electrolytic cell. The ferrocene was eluted through a silica gel column using a mixture of a mobile phase of supercritical CO 2 and a modifier of methanol containing ammonium acetate. The current peak area of ferrocene correlated to the ferrocene concentration in the range of 10-400 μmol/L (r = 0.999). Moreover, the limit of detection on the column estimated from a signal-to-noise ratio of 3 was 9.8 × 10 -13 mol. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
21 CFR 872.3680 - Polytetrafluoroethylene (PTFE) vitreous carbon materials.
Code of Federal Regulations, 2010 CFR
2010-04-01
... the sockets in which teeth are rooted) or intended to coat metal surgical implants to be placed in the alveoli (sockets in which the teeth are rooted) or the temporomandibular joints (the joint between the...
21 CFR 872.3680 - Polytetrafluoroethylene (PTFE) vitreous carbon materials.
Code of Federal Regulations, 2013 CFR
2013-04-01
... the sockets in which teeth are rooted) or intended to coat metal surgical implants to be placed in the alveoli (sockets in which the teeth are rooted) or the temporomandibular joints (the joint between the...
21 CFR 872.3680 - Polytetrafluoroethylene (PTFE) vitreous carbon materials.
Code of Federal Regulations, 2014 CFR
2014-04-01
... the sockets in which teeth are rooted) or intended to coat metal surgical implants to be placed in the alveoli (sockets in which the teeth are rooted) or the temporomandibular joints (the joint between the...
21 CFR 872.3680 - Polytetrafluoroethylene (PTFE) vitreous carbon materials.
Code of Federal Regulations, 2011 CFR
2011-04-01
... the sockets in which teeth are rooted) or intended to coat metal surgical implants to be placed in the alveoli (sockets in which the teeth are rooted) or the temporomandibular joints (the joint between the...
21 CFR 872.3680 - Polytetrafluoroethylene (PTFE) vitreous carbon materials.
Code of Federal Regulations, 2012 CFR
2012-04-01
... the sockets in which teeth are rooted) or intended to coat metal surgical implants to be placed in the alveoli (sockets in which the teeth are rooted) or the temporomandibular joints (the joint between the...
New electrocatalysts for hydrogen-oxygen fuel cells
NASA Technical Reports Server (NTRS)
Cattabriga, R. A.; Giner, J.; Parry, J.; Swette, L. L.
1970-01-01
Platinum-silver, palladium-gold, and platinum-gold alloys serve as oxygen reduction catalysts in high-current-density cells. Catalysts were tested on polytetrafluoroethylene-bonded cathodes and a hydrogen anode at an operating cell temperature of 80 degrees C.
21 CFR 878.3500 - Polytetrafluoroethylene with carbon fibers composite implant material.
Code of Federal Regulations, 2014 CFR
2014-04-01
..., DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES... material intended to be implanted during surgery of the chin, jaw, nose, or bones or tissue near the eye or...
21 CFR 878.3500 - Polytetrafluoroethylene with carbon fibers composite implant material.
Code of Federal Regulations, 2013 CFR
2013-04-01
..., DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES... material intended to be implanted during surgery of the chin, jaw, nose, or bones or tissue near the eye or...
21 CFR 878.3500 - Polytetrafluoroethylene with carbon fibers composite implant material.
Code of Federal Regulations, 2012 CFR
2012-04-01
..., DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES... material intended to be implanted during surgery of the chin, jaw, nose, or bones or tissue near the eye or...
Measurement of the absolute reflectance of polytetrafluoroethylene (PTFE) immersed in liquid xenon
NASA Astrophysics Data System (ADS)
Neves, F.; Lindote, A.; Morozov, A.; Solovov, V.; Silva, C.; Bras, P.; Rodrigues, J. P.; Lopes, M. I.
2017-01-01
The performance of a detector using liquid xenon (LXe) as a scintillator is strongly dependent on the collection efficiency for xenon scintillation light, which in turn is critically dependent on the reflectance of the surfaces that surround the active volume. To improve the light collection in such detectors the active volume is usually surrounded by polytetrafluoroethylene (PTFE) reflector panels, used due to its very high reflectance—even at the short wavelength of scintillation light of LXe (peaked at 178 nm). In this work, which contributed to the overall R&D effort towards the LUX-ZEPLIN (LZ) experiment, we present experimental results for the absolute reflectance measurements of three different PTFE samples (including the material used in the LUX detector) immersed in LXe for its scintillation light. The obtained results show that very high bi-hemispherical reflectance values (>= 97%) can be achieved, enabling very low energy thresholds in liquid xenon scintillator-based detectors.
NASA Astrophysics Data System (ADS)
Reznickova, Alena; Kvitek, Ondrej; Kolarova, Katerina; Smejkalova, Zuzana; Svorcik, Vaclav
2017-06-01
The aim of this article is to investigate the effect of the interface between plasma activated, gold and carbon coated poly(tetrafluoroethylene) (PTFE) on in vitro adhesion and spreading of mouse fibroblasts (L929). Surface properties of pristine and modified PTFE were studied by several experimental techniques. The thickness of a deposited gold film is an increasing function of the sputtering time, conversely thickness of carbon layer decreases with increasing distance between carbon source and the substrate. Because all the used surface modification techniques take place in inert Ar plasma, oxidized degradation products are formed on the PTFE surface, which affects wettability of the polymer surface. Cytocompatibility tests indicate that on samples with Au/C interface, the cells accumulate on the part of sample with evaporated carbon. Number of L929 cells proliferated on the studied samples is comparable to tissue culture polystyrene standard.
Su, Yuanjie; Yang, Ya; Zhang, Hulin; Xie, Yannan; Wu, Zhiming; Jiang, Yadong; Fukata, Naoki; Bando, Yoshio; Wang, Zhong Lin
2013-07-26
Methyl orange (MO) can be degraded by a photocatalytic process using TiO₂ under UV irradiation. The photo-generated holes and electrons can migrate to the surface of TiO₂ particles and serve as redox sources that react with adsorbed reactants, leading to the formation of superoxide radical anions, hydrogen peroxide and hydroxyl radicals involved in the oxidation of dye pollution. Here, we fabricated a polytetrafluoroethylene-Al based triboelectric nanogenerator (TENG) whose electric power output can be used for enhancing the photodegradation of MO with the presence of TiO₂ nanoparticles, because the TENG generated electric field can effectively boost the separation and restrain the recombination of photo-generated electrons and holes. Due to the photoelectrical coupling, the degradation percentages of MO for 120 min with and without TENG assistance are 76% and 27%, respectively. The fabricated TENGs have potential applications in wastewater treatment, water splitting, and pollution degradation.
Reflectance of polytetrafluoroethylene for xenon scintillation light
NASA Astrophysics Data System (ADS)
Silva, C.; Pinto da Cunha, J.; Pereira, A.; Chepel, V.; Lopes, M. I.; Solovov, V.; Neves, F.
2010-03-01
Gaseous and liquid xenon particle detectors are being used in a number of applications including dark matter search and neutrino-less double beta decay experiments. Polytetrafluoroethylene (PTFE) is often used in these detectors both as electrical insulator and as a light reflector to improve the efficiency of detection of scintillation photons. However, xenon emits in the vacuum ultraviolet (VUV) wavelength region (λ ≃175 nm) where the reflecting properties of PTFE are not sufficiently known. In this work, we report on measurements of PTFE reflectance, including its angular distribution, for the xenon scintillation light. Various samples of PTFE, manufactured by different processes (extruded, expanded, skived, and pressed) have been studied. The data were interpreted with a physical model comprising both specular and diffuse reflections. The reflectance obtained for these samples ranges from about 47% to 66% for VUV light. Other fluoropolymers, namely, ethylene tetrafluoroethylene (ETFE), fluorinated ethylene propylene (FEP), and perfluoro-alkoxyalkane (PFA) were also measured.
Superhydrophobic and icephobic surfaces prepared by RF-sputtered polytetrafluoroethylene coatings
NASA Astrophysics Data System (ADS)
Jafari, R.; Menini, R.; Farzaneh, M.
2010-12-01
A superhydrophobic and icephobic surface were investigated on aluminum alloy substrate. Anodizing was used first to create a micro-nanostructured aluminum oxide underlayer on the alloy substrate. In a second step, the rough surface was coated with RF-sputtered polytetrafluoroethylene (PTFE or Teflon ®). Scanning electron microscopy images showed a " bird's nest"-like structure on the anodized surface. The RF-sputtered PTFE coating exhibited a high static contact angle of ˜165° with a very low contact angle hysteresis of ˜3°. X-ray photoelectron spectroscopy (XPS) results showed high quantities of CF 3 and CF 2 groups, which are responsible for the hydrophobic behavior of the coatings. The performance of this superhydrophobic film was studied under atmospheric icing conditions. These results showed that on superhydrophobic surfaces ice-adhesion strength was 3.5 times lower than on the polished aluminum substrate.
The use of an ion-beam source to alter the surface morphology of biological implant materials
NASA Technical Reports Server (NTRS)
Weigand, A. J.
1978-01-01
An electron-bombardment ion-thruster was used as a neutralized-ion-beam sputtering source to texture the surfaces of biological implant materials. The materials investigated included 316 stainless steel; titanium-6% aluminum, 4% vanadium; cobalt-20% chromium, 15% tungsten; cobalt-35% nickel, 20% chromium, 10% molybdenum; polytetrafluoroethylene; polyoxymethylene; silicone and polyurethane copolymer; 32%-carbon-impregnated polyolefin; segmented polyurethane; silicone rubber; and alumina. Scanning electron microscopy was used to determine surface morphology changes of all materials after ion-texturing. Electron spectroscopy for chemical analysis was used to determine the effects of ion-texturing on the surface chemical composition of some polymers. Liquid contact angle data were obtained for ion-textured and untextured polymer samples. Results of tensile and fatigue tests of ion-textured metal alloys are presented. Preliminary data of tissue response to ion-textured surfaces of some metals, polytetrafluoroethylene, alumina, and segmented polyurethane have been obtained.
Adhesion and transfer of polytetrafluoroethylene to tungsten studied by field ion microscopy
NASA Technical Reports Server (NTRS)
Brainard, W. A.; Buckley, D. H.
1972-01-01
Mechanical contacts between polytetrafluoroethylene (PTFE) and tungsten field ion tips were made in situ in the field ion microscope. Both load and force of adhesion were measured for varying contact times and for clean and contaminated tungsten tips. Strong adhesion between the PTFE and clean tungsten was observed at contact times greater than 2.5 min (forces of adhesion were greater than three times the load). For times less than 2.5 min, the force of adhesion was immeasurably small. The increase in adhesion with contact time after 2.5 min can be attributed to the increase in true contact area by creep of PTFE. No adhesion was measurable at long contact times with contaminated tungsten tips. Neon field ion micrographs taken after the contacts show many linear and branched arrays which appear to represent PTFE that remains adhered to the surface even at the high electric fields required for imaging.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-07-18
... (``PTFE resin'') from Italy would likely lead to a continuation or recurrence of dumping and material... initiation of the third sunset review of the antidumping duty order on PTFE resin from Italy, pursuant to...
Two-Band, Low-Loss Microwave Window
NASA Technical Reports Server (NTRS)
Britcliffe, Michael; Franco, Manuel
2007-01-01
A window for a high-sensitivity microwave receiving system allows microwave radiation to pass through to a cryogenically cooled microwave feed system in a vacuum chamber, while keeping ambient air out of the chamber and helping to keep the interior of the chamber cold. The microwave feed system comprises a feed horn and a low-noise amplifier, both of which are required to be cooled to a temperature of 15 K during operation. The window is designed to exhibit very little microwave attenuation in two frequency bands: 8 to 9 GHz and 30 to 40 GHz. The window is 15 cm in diameter. It includes three layers (see figure): 1) The outer layer is made of a poly(tetrafluoroethylene) film 0.025 mm thick. This layer serves primarily to reflect and absorb solar ultraviolet radiation to prolong the life of the underlying main window layer, which is made of a polyimide that becomes weakened when exposed to ultraviolet. The poly(tetrafluoroethylene) layer also protects the main window layer against abrasion. Moreover, the inherent hydrophobicity of poly(tetrafluoroethylene) helps to prevent the highly undesirable accumulation of water on the outer surface. 2) The polyimide main window layer is 0.08 mm thick. This layer provides the vacuum seal for the window. 3) A 20-mm-thick layer of ethylene/ propylene copolymer foam underlies the main polyimide window layer. This foam layer acts partly as a thermal insulator: it limits radiational heating of the microwave feed horn and, concomitantly, limits radiational cooling of the window. This layer has high compressive strength and provides some mechanical support for the main window layer, reducing the strength required of the main window layer. The ethylene/propylene copolymer foam layer is attached to an aluminum window ring by means of epoxy. The outer poly(tetrafluoroethylene) film and the main polyimide window layer are sandwiched together and pressed against the window ring by use of a bolted clamp ring. The window has been found to introduce a microwave loss of only about 0.4 percent. The contribution of the window to the noise temperature of the microwave feed system has been found to be less than 1 K at 32 GHz and 0.2 K at 8.4 GHz.
Corrosion-Resistant Ball Bearings
NASA Technical Reports Server (NTRS)
Zdankiewicz, E. M.; Linaburg, E. L.; Lytle, L. J.
1990-01-01
Self-lubricating bearing system withstands highly corrosive environment of wastewater-recycling unit. New bearings contain cobalt-based-alloy balls and races, graphite/polyimide polymer ball cages, and single integral polytetrafluoroethylene seals on wet sides. Materials and design prevent corrosion by acids and provide lubrication.
High-temperature flat-conductor cable
NASA Technical Reports Server (NTRS)
Rigling, W. S.
1976-01-01
Temperature limit of 25-conductor signal cable and 3-conductor power cable, fabricated using woven and roll laminated technique, increased from 200 C to 350 C when polyimide/fluorinated ethylene propylene or polytetrafluoroethylene insulation films and fluorinated ethylene propylene as adhesive medium is applied.
Segmental liver incarceration through a recurrent incisional lumbar hernia.
Salemis, Nikolaos S; Nisotakis, Konstantinos; Gourgiotis, Stavros; Tsohataridis, Efstathios
2007-08-01
Lumbar hernia is a rare congenital or acquired defect of the posterior abdominal wall. The acquired type is more common and occurs mainly as an incisional defect after flank surgery. Incarceration or strangulation of hernia contents is uncommon. Segmental liver incarceration through a recurrent incisional lumbar defect was diagnosed in a 58 years old woman by magnetic resonance imaging. The patient underwent an open repair of the complicated hernia. An expanded polytetraflouoroethylene (e-PTFE) mesh was fashioned as a sublay prosthesis. She had an uncomplicated postoperative course. Follow-up examinations revealed no evidence of recurrence. Although lumbar hernia rarely results in incarceration or strangulation, early repair is necessary because of the risks of complications and the increasing difficulty in repairment as it enlarges. Surgical repair is often difficult and challenging.
21 CFR 870.3450 - Vascular graft prosthesis.
Code of Federal Regulations, 2014 CFR
2014-04-01
... terephthalate and polytetrafluoroethylene, and it may be coated with a biological coating, such as albumin or... animal origin, including human umbilical cords. (b) Classification. Class II (special controls). The special control for this device is the FDA guidance document entitled “Guidance Document for Vascular...
21 CFR 870.3450 - Vascular graft prosthesis.
Code of Federal Regulations, 2012 CFR
2012-04-01
... terephthalate and polytetrafluoroethylene, and it may be coated with a biological coating, such as albumin or... animal origin, including human umbilical cords. (b) Classification. Class II (special controls). The special control for this device is the FDA guidance document entitled “Guidance Document for Vascular...
21 CFR 870.3450 - Vascular graft prosthesis.
Code of Federal Regulations, 2013 CFR
2013-04-01
... terephthalate and polytetrafluoroethylene, and it may be coated with a biological coating, such as albumin or... animal origin, including human umbilical cords. (b) Classification. Class II (special controls). The special control for this device is the FDA guidance document entitled “Guidance Document for Vascular...
Strain relief for power-cable connectors
NASA Technical Reports Server (NTRS)
Dean, W. T., III
1980-01-01
Easily fabricated grommet composed of polytetrafluoroethylene cylinder, containing U-shaped channels equally spaced around periphery, is used in power cable connectors to relieve strain on cables. Utilization of grommets provides more ease in cable insertion and removal. Potential applications include wiring in large residential and commercial buildings.
21 CFR 870.3450 - Vascular graft prosthesis.
Code of Federal Regulations, 2011 CFR
2011-04-01
... terephthalate and polytetrafluoroethylene, and it may be coated with a biological coating, such as albumin or... animal origin, including human umbilical cords. (b) Classification. Class II (special controls). The special control for this device is the FDA guidance document entitled “Guidance Document for Vascular...
NASA Technical Reports Server (NTRS)
Kirby, C. E.
1972-01-01
Coating condensing surfaces with thin layer of nonpolar Teflon results in dropwise condensation of polar organic vapor. Greater heat transfer coefficients are produced increasing effectiveness of condensing system. Investigation shows that vapors with strong dipole moment tend to condense dropwise.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mermuys, Koen; Maleux, Geert, E-mail: geert.maleux@uzleuven.be; Heye, Sam
2008-07-15
Four children, three boys and one girl, with a median age of 9 years 8 months, underwent transjugular intrahepatic portosystemic shunt creation with an expanded polytetrafluoroethylene (e-PTFE)-covered nitinol stent. The stent-graft was successfully placed in all four patients without any complication. Clinical and biochemical improvement was noted in all four patients during follow-up. Radiological follow-up with use of duplex ultrasound showed a recurrent stenosis of the shunt 180 days after stent-graft implantation in one patient. This was treated with placement of an additional stent-graft, re-expanding completely the recurrent stenosis. In the other three patients, the stent-graft remained fully patent untilmore » the end of the study or until orthotopic liver transplantation. These preliminary results suggest that use of the Viatorr ePTFE-covered stent-graft in children is safe and feasible, with potentially the same high patency rate and improved clinical outcome as reported in adult patients.« less
NASA Technical Reports Server (NTRS)
Wheeler, Donald R.; Pepper, Stephen V.
1990-01-01
Polytetrafluoroethylene (PTFE) was subjected to 3 keV electron bombardment and then heated in vacuum to 300 C. The behavior of the material as a function of radiation dose and temperature was studied by X-ray photoelectron spectroscopy (XPS) of the surface and mass spectroscopy of the species evolved. Lightly damaged material heated to 300 C evolved saturated fluorocarbon species, whereas unsaturated fluorocarbon species were evolved from heavily damaged material. After heating the heavily damaged material, those features in the XPS spectrum that were associated with damage diminished, giving the appearance that the radiation damage had annealed. The observations were interpreted by incorporating mass transport of severed chain fragments and thermal decomposition of severely damaged material into the branched and cross-linked network model of irradiated PTFE. The apparent annealing of the radiation damage was due to covering of the network by saturated fragments that easily diffused through the decomposed material to the surface region upon heating.
NASA Technical Reports Server (NTRS)
Wheeler, Donald R.; Pepper, Stephen V.
1990-01-01
Polytetrafluoroethylene (PTFE) was subjected to 3 keV electron bombardment and then heated in vacuum to 300 C. The behavior of the material as a function of radiation dose and temperature was studied by X-ray photoelectron spectroscopy (XPS) of the surface and mass spectroscopy of the species evolved. A quantitative comparison of the radiation dose rate with that in other reported studies showed that, for a given total dose, the damage observed by XPS is greater for higher dose rates. Lightly damaged material heated to 300 C evolved saturated fluorocarbon species, whereas unsaturated fluorocarbon species evolved from heavily damaged material. After heating the heavily damaged material, those features in the XPS that were associated with damage diminished, giving the appearance that the radiation damage annealed. The apparent annealing of the radiation damage was found to be due to the covering of the network by saturated fragments that easily diffused through the decomposed material to the surface region upon heating.
Sputtered coatings for protection of spacecraft polymers
NASA Technical Reports Server (NTRS)
Banks, B. A.; Mirtich, M. J.; Rutledge, S. K.; Swec, D. M.
1983-01-01
Kapton polyimide oxidizes at significant rates (4.3x10(-24) gram/incident oxygen atom) when exposed in low Earth orbit to the ram atomic oxygen flux. Ion beam sputter deposited thin films of Al2O3 and SiO2 as well as a codeposited mixture of predominantly SiO2 with a small amount of polytetrafluoroethylene were evaluated and found to be effective in protecting Kapton from oxidation in both laboratory plasma ashing tests as well as in space on board shuttle flight STS-8. A protective film of or = 96 percent SiO2 and or = 4 percent polytetrafluoroethylene was found to be very flexible compared to the pure metal oxide coatings and resulted in mass loss rates that were 0.2 percent of that of the unprotected Kapton. The optical properties of Kapton for wavelengths investigated between 0.33 and 2.2 microns were not significantly altered by the presence of the coatings or changed by exposure of the coated Kapton to the low Earth orbital ram environment.
NASA Astrophysics Data System (ADS)
Wyszkowska, Edyta; Leśniak, Magdalena; Kurpaska, Lukasz; Prokopowicz, Rafal; Jozwik, Iwona; Sitarz, Maciej; Jagielski, Jacek
2018-04-01
In this study structural and nanomechanical properties of polytetrafluoroethylene (PTFE) used as a gasket in the nuclear reactor have been deeply investigated. In order to reveal structural changes caused by long-term pressure, temperature and irradiation (possibly neutron and gamma), methods such as SEM, X-ray diffraction and Raman Spectroscopy have been used. Nanomechanical properties such as Young Modulus and hardness were investigated by means of the nanoindentation technique. Presented study confirmed the influence of working (radiative) environment on the functional properties of PTFE. The results of Raman spectroscopy and X-ray diffraction techniques revealed shift of the major band positions and band intensities increase. Moreover, changes of hardness and Young Modulus values of the irradiated material with respect to the virgin specimen have been recorded. This phenomenon can be attributed to the modifications in crystallinity of the material. Presented work suggest that morphology of the irradiated material altered from well-ordered parallel fibers to more dense and thicker ones.
Decomposition pathways of polytetrafluoroethylene by co-grinding with strontium/calcium oxides.
Qu, Jun; He, Xiaoman; Zhang, Qiwu; Liu, Xinzhong; Saito, Fumio
2017-06-01
Waste polytetrafluoroethylene (PTFE) could be easily decomposed by co-grinding with inorganic additive such as strontium oxide (SrO), strontium peroxide (SrO 2 ) and calcium oxide (CaO) by using a planetary ball mill, in which the fluorine was transformed into nontoxic inorganic fluoride salts such as strontium fluoride (SrF 2 ) or calcium fluoride (CaF 2 ). Depending on the kind of additive as well as the added molar ratio, however, the reaction mechanism of the decomposition was found to change, with different compositions of carbon compounds formed. CO gas, the mixture of strontium carbonate (SrCO 3 ) and carbon, only SrCO 3 were obtained as reaction products respectively with equimolar SrO, excess SrO and excess SrO 2 to the monomer unit CF 2 of PTFE were used. Excess amount of CaO was needed to effectively decompose PTFE because of its lower reactivity compared with strontium oxide, but it promised practical applications due to its low cost.
Removable polytetrafluoroethylene template based epitaxy of ferroelectric copolymer thin films
NASA Astrophysics Data System (ADS)
Xia, Wei; Chen, Qiusong; Zhang, Jian; Wang, Hui; Cheng, Qian; Jiang, Yulong; Zhu, Guodong
2018-04-01
In recent years ferroelectric polymers have shown their great potentials in organic and flexible electronics. To meet the requirements of high-performance and low energy consumption of novel electronic devices and systems, structural and electrical properties of ferroelectric polymer thin films are expected to be further optimized. One possible way is to realize epitaxial growth of ferroelectric thin films via removable high-ordered polytetrafluoroethylene (PTFE) templates. Here two key parameters in epitaxy process, annealing temperature and applied pressure, are systematically studied and thus optimized through structural and electrical measurements of ferroelectric copolymer thin films. Experimental results indicate that controlled epitaxial growth is realized via suitable combination of both parameters. Annealing temperature above the melting point of ferroelectric copolymer films is required, and simultaneously moderate pressure (around 2.0 MPa here) should be applied. Over-low pressure (around 1.0 MPa here) usually results in the failure of epitaxy process, while over-high pressure (around 3.0 MPa here) often results in residual of PTFE templates on ferroelectric thin films.
76 FR 4936 - Granular Polytetrafluoroethylene Resin From Italy
Federal Register 2010, 2011, 2012, 2013, 2014
2011-01-27
..., 2010. \\3\\ Commerce's January 13, 2011, letter does not indicate a change concerning its intent to.... General information concerning the Commission may also be obtained by accessing its Internet server ( http... published its notice of institution and the Department of Commerce (``Commerce'') published its notice of...
Feed-through connector couples RF power into vacuum chamber
NASA Technical Reports Server (NTRS)
Grandy, G. L.
1967-01-01
Feed-through device connects RF power to an RF coil in a vacuum chamber. The coil and leads are water cooled and vacuum tight seals are provided at the junctions. The device incorporates silver soldered copper tubes, polytetrafluoroethylene electrical insulators, and O-ring vacuum seals.
75 FR 67105 - Granular Polytetrafluoroethylene Resin From Italy and Japan
Federal Register 2010, 2011, 2012, 2013, 2014
2010-11-01
... conditions or business cycle for the Domestic Like Product that have occurred in the United States or in the... Ethics Official, at 202-205-3088. Limited disclosure of business proprietary information (BPI) under an.../worker group, or trade/business association; import/export Subject [[Page 67107
Code of Federal Regulations, 2013 CFR
2013-07-01
...) Polytetrafluoroethylene, DCN No. 63040000018B ......do Do. Fluorotelomer-based composite substance: (1) For Paper containing three of the following chemical substances as specified in the ECA: (i) Perfluoroalkylethyl...) Perfluoroalkyl acrylate copolymer, ACC 158022 ......do Do. (iii) Perfluoroalkyl methacrylate polymer, EPA...
Dong, Qing-shan; Shang, Hong-tao; Wu, Wei; Chen, Fu-lin; Zhang, Jun-rui; Guo, Jia-ping; Mao, Tian-qiu
2012-08-01
The most important problem for the survival of thick 3-dimensional tissues is the lack of vascularization in the context of bone tissue engineering. In this study, a modified arteriovenous loop (AVL) was developed to prefabricate an axial vascularized tissue engineering coral bone in rabbit, with comparison of the arteriovenous bundle (AVB) model. An arteriovenous fistula between rabbit femoral artery and vein was anastomosed to form an AVL. It was placed in a circular side groove of the coral block. The complex was wrapped with an expanded-polytetrafluoroethylene membrane and implanted beneath inguinal skin. After 2, 4, 6 and 8 weeks, the degree of vascularization was evaluated by India ink perfusion, histological examination, vascular casts, and scanning electron microscopy images of vascular endangium. Newly formed fibrous tissues and vasculature extended over the surfaces and invaded the interspaces of entire coral block. The new blood vessels robustly sprouted from the AVL. Those invaginated cavities in the vascular endangium from scanning electron microscopy indicated vessel's sprouted pores. Above indexes in AVL model are all superior to that in AVB model, indicating that the modified AVL model could more effectively develop vascularization in larger tissue engineering bone. Copyright © 2012 Elsevier B.V. All rights reserved.
A dynamic and harmonic damped finite element analysis model of stapedotomy.
Blayney, A W; Williams, K R; Rice, H J
1997-03-01
This study was undertaken in an attempt to better understand the mechanics of sound transmission at the footplate following stapedotomy. The insertion of a Teflon (polytetrafluoroethylene) stapes prosthesis introduces new constraints within the reconstructed ossicular chain which have an effect on the normal vibration patterns of the tympanic membrane. In a finite element model of the ear, constraints have been reproduced as a series of spring constants in the incus/prosthesis/footplate interfaces incorporating damping to simulate the impedance of the inner ear. At zero damping, the frequency response at the pseudo stapes footplate exhibit several maxima and minima between 800 Hz and 2.5 Hz. At higher damping values, these maxima and minima become smoothened out with two or three naturals occurring over the same frequency range. Severe ankylosis of a diseased footplate is reproduced by over-damped conditions. The umbo, incus and stapes footplate vibrate in phase with similar frequencies at light damping levels. The movement of the prosthesis at the pseudo-footplate can be large in the out of plane axis of the ossicular chain, unless sufficient support is provided at the reconstructed footplate. Clinically, this would suggest the vein graft interposed between the piston and stapedotomy hole should endow resistance and elasticity to the system.
78 FR 59653 - Notice of Scope Rulings
Federal Register 2010, 2011, 2012, 2013, 2014
2013-09-27
... Administration, U.S. Department of Commerce, 14th Street and Constitution Avenue NW., Washington, DC 20230... polytetrafluoroethylene (PTFE) resin products made from raw, unfilled PTFE powder from Russia and the People's Republic of... the antidumping duty order; April 26, 2013 (preliminary). People's Republic of China A-570-967 and C...
2014-03-27
in a thin conductive layer, the wafer surface can be made into the cathode while using a stainless steel plate as an anode. Bath temperature, voltage...beakers with polytetrafluoroethylene (PTFE) tools while under a fume hood, as HF is known to attack glass and polystyrene [62]. Additionally
Federal Register 2010, 2011, 2012, 2013, 2014
2013-02-19
.... SUPPLEMENTARY INFORMATION: Background Pursuant to a request by Industrial Plastics and Machine, Inc... Revocation in Part, 77 FR 59168 (September 26, 2012). \\2\\ See Letter from Industrial Plastics and Machine... estimated antidumping duties required at the time of entry, or withdrawal from warehouse, for consumption in...
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Intracardiac patch or pledget made of... CARDIOVASCULAR DEVICES Cardiovascular Prosthetic Devices § 870.3470 Intracardiac patch or pledget made of... or pledget made of polypropylene, polyethylene terephthalate, or polytetrafluoroethylene is a fabric...
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Intracardiac patch or pledget made of... CARDIOVASCULAR DEVICES Cardiovascular Prosthetic Devices § 870.3470 Intracardiac patch or pledget made of... or pledget made of polypropylene, polyethylene terephthalate, or polytetrafluoroethylene is a fabric...
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Intracardiac patch or pledget made of... CARDIOVASCULAR DEVICES Cardiovascular Prosthetic Devices § 870.3470 Intracardiac patch or pledget made of... or pledget made of polypropylene, polyethylene terephthalate, or polytetrafluoroethylene is a fabric...
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Intracardiac patch or pledget made of... CARDIOVASCULAR DEVICES Cardiovascular Prosthetic Devices § 870.3470 Intracardiac patch or pledget made of... or pledget made of polypropylene, polyethylene terephthalate, or polytetrafluoroethylene is a fabric...
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Intracardiac patch or pledget made of... CARDIOVASCULAR DEVICES Cardiovascular Prosthetic Devices § 870.3470 Intracardiac patch or pledget made of... or pledget made of polypropylene, polyethylene terephthalate, or polytetrafluoroethylene is a fabric...
Passive, Low Cost Neutron Detectors for Neutron Diagnostics at the National Ignition Facility
2013-03-01
Facility PTFE Polytetrafluoroethylene TLD Thermoluminescent Dosimeter α Conversion Coefficient (Conversion...because they required a large investment in automated track counting equipment. Thermoluminescent dosimeters ( TLDs ) remained as a viable option. They...necessary to predict radiation damage to measurement electronics . Due to programmatic and facility limitations, traditional neutron measurement
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhang, JunMin, E-mail: jmzhang@buaa.edu.cn, E-mail: guanyg@tsinghua.edu.cn; Lu, ChunRong; Guan, YongGang, E-mail: jmzhang@buaa.edu.cn, E-mail: guanyg@tsinghua.edu.cn
2015-10-15
Because the fault arc in aircraft electrical system often causes a fire, it is particularly important to analyze its energy and transfer for aircraft safety. The calculation of arc energy requires the basic parameters of the arc. This paper is mainly devoted to the calculations of equilibrium composition, thermodynamic properties (density, molar weight, enthalpy, and specific heat at constant pressure) and transport coefficients (thermal conductivity, electrical conductivity, and viscosity) of plasmas produced by a mixture of air, Cu, and polytetrafluoroethylene under the condition of local thermodynamic equilibrium. The equilibrium composition is determined by solving a system of equations around themore » number densities of each species. The thermodynamic properties are obtained according to the standard thermodynamic relationships. The transport coefficients are calculated using the Chapman-Enskog approximations. Results are presented in the temperature range from 3000 to 30 000 K for pressures of 0.08 and 0.1 MPa, respectively. The results are more accurate and are reliable reference data for theoretical analysis and computational simulation of the behavior of fault arc.« less
Viscoelastic properties of rabbit vocal folds after augmentation.
Hertegård, Stellan; Dahlqvist, Ake; Laurent, Claude; Borzacchiello, Assunta; Ambrosio, Luigi
2003-03-01
Vocal fold function is closely related to tissue viscoelasticity. Augmentation substances may alter the viscoelastic properties of vocal fold tissues and hence their vibratory capacity. We sought to investigate the viscoelastic properties of rabbit vocal folds in vitro after injections of various augmentation substances. Polytetrafluoroethylene (Teflon), cross-linked collagen (Zyplast), and cross-linked hyaluronan, hylan b gel (Hylaform) were injected into the lamina propria and the thyroarytenoid muscle of rabbit vocal folds. Dynamic viscosity of the injected vocal fold as a function of frequency was measured with a Bohlin parallel-plate rheometer during small-amplitude oscillation. All injected vocal folds showed a decreasing dynamic viscosity with increasing frequency. Vocal fold samples injected with hylan b gel showed the lowest dynamic viscosity, quite close to noninjected control samples. Vocal folds injected with polytetrafluoroethylene showed the highest dynamic viscosity followed by the collagen samples. The data indicated that hylan b gel in short-term renders the most natural viscoelastic properties to the vocal fold among the substances tested. This is of importance to restore/preserve the vibratory capacity of the vocal folds when glottal insufficiency is treated with injections.
Fabrication of transparent superhydrophobic polytetrafluoroethylene coating
NASA Astrophysics Data System (ADS)
Alawajji, Raad A.; Kannarpady, Ganesh K.; Biris, Alexandru S.
2018-06-01
Polytetrafluoroethylene (PTFE) thin films were successfully deposited on glass substrates using pulsed laser deposition, with deposition times ranging from 30 to 120 minutes (min). The surface roughness of the films increased as deposition time increased, with micro/nanoscale roughness developing when deposition time increased over 60 min. This roughness made the surface superhydrophobic, having a contact angle of about 151.6°±1. UV-vis spectroscopic analysis of the PTFE films revealed that they were highly transparent, up to ∼90% in visible and near-infrared ranges. Furthermore, when the deposition time was increased-which increased the films' thickness-the films were able to absorb 80-90% of ultraviolet light in the wavelength range <300 nm. The researchers used an x-ray photoelectron spectrometer to find the chemical and elemental composition of the films' surfaces. Atomic force microscopy was used to determine the effect of surface roughness on the films' hydrophobicity. The fabricated superhydrophobic films have many potential practical uses, from self-cleaning materials to solar cell panel coatings. Additionally, the low dielectric properties of PTFE make the films' ideal for communication antenna coatings and similar applications.
Shock, release and Taylor impact of the semicrystalline thermoplastic polytetrafluoroethylene
NASA Astrophysics Data System (ADS)
Bourne, N. K.; Brown, E. N.; Millett, J. C. F.; Gray, G. T.
2008-04-01
The high strain-rate response of polymers is a subject that has gathered interest over recent years due to their increasing engineering importance, particularly in load bearing applications subject to extremes of pressure and strain rate. The current work presents two specific sets of experiments interrogating the effect of dynamic, high-pressure loading in the regime of the phase II to phase III pressure-induced crystalline phase transition in polytetrafluoroethylene (PTFE). These are gas-gun driven plate- and Taylor impact. Together these experiments highlight several effects associated with the dynamic, pressure-induced phase transitions in PTFE. An elevated release wave speed shows evidence of a pressure-induced phase change at a stress commensurate with that observed statically. It is shown that convergence between analytic derivations of release wave speed and the data requires the phase II to III transition to occur. Taylor impact is an integrated test that highlights continuum behavior that has origin in mesoscale response. There is a rapid transition from ductile to brittle behavior observed that occurs at a pressure consistent with this phase transition.
Yu, W H; Kang, E T; Neoh, K G
2005-01-04
Surface modification of poly(tetrafluoroethylene) (PTFE) films by well-defined comb copolymer brushes was carried out. Peroxide initiators were generated directly on the PTFE film surface via radio frequency Ar plasma pretreatment, followed by air exposure. Poly(glycidyl methacrylate) (PGMA) brushes were first prepared by surface-initiated reversible addition-fragmentation chain transfer polymerization from the peroxide initiators on the PTFE surface in the presence of a chain transfer agent. Kinetics study revealed a linear increase in the graft concentration of PGMA with the reaction time, indicating that the chain growth from the surface was consistent with a "controlled" or "living" process. alpha-Bromoester moieties were attached to the grafted PGMA by reaction of the epoxide groups with 2-bromo-2-methylpropionic acid. The comb copolymer brushes were subsequently prepared via surface-initiated atom transfer radical polymerization of two hydrophilic vinyl monomers, including poly(ethylene glycol) methyl ether methacrylate and sodium salt of 4-styrenesulfonic acid. The chemical composition of the modified PTFE surfaces was characterized by X-ray photoelectron spectroscopy.
Antibiotic bonding to polytetrafluoroethylene with tridodecylmethylammonium chloride
DOE Office of Scientific and Technical Information (OSTI.GOV)
Harvey, R.A.; Alcid, D.V.; Greco, R.S.
Polytetrafluoroethylene (PTFE) treated with the cationic surfactant, triodecylmethylammonium chloride (TDMAC), binds /sup 14/C-penicillin (1.5 to 2 mg antibiotic/cm graft), whereas untreated PTFE or PTFE treated with anionic detergents shows little binding of antibiotic. TDMAC-treated PTFE concomitantly binds penicillin and heparin, generating a surface that potentially can resist both infection and thrombosis. The retention of these biologically active molecules is not due to passive entrapment in the PTFE but reflects an ionic interaction between the anionic ligands and surface-bound TDMAC. Penicillin bound to PTFE is not removed by exhaustive washing in aqueous buffers but is slowly released in the presence ofmore » plasma or when the PTFE is placed in a muscle pouch in the rat. Muscle tissue adjacent to the treated PTFE shows elevated levels of antibiotic following implantation. PTFE treated with TDMAC and placed in a muscle pouch binds /sup 14/C-penicillin when it is locally irrigated with antibiotic or when penicillin is administered intravenously. Thus, the TDMAC surface treated either in vitro or in vivo with penicillin provides an effective in situ source for the timed release of antibiotic.« less
Germer, Thomas A
2017-11-20
We measured the Mueller matrix bidirectional reflectance distribution function (BRDF) of a sintered polytetrafluoroethylene (PTFE) sample over the scattering hemisphere for six incident angles (0°-75° in 15° steps) and for four wavelengths (351 nm, 532 nm, 633 nm, and 1064 nm). The data for each wavelength were fit to a phenomenological description for the Mueller matrix BRDF, which is an extension of the bidirectional surface scattering modes developed by Koenderink and van Doorn [J. Opt. Soc. Am. A.15, 2903 (1998)JOAOD60740-323210.1364/JOSAA.15.002903] for unpolarized BRDF. This description is designed to be complete, to obey the appropriate reciprocity conditions, and to provide a full description of the Mueller matrix BRDF as a function of incident and scattering directions for each wavelength. The description was further extended by linearizing the surface scattering mode coefficients with wavelength. This data set and its parameterization provides a comprehensive on-demand description of the reflectance properties for this commonly used diffuse reflectance reference material over a wide range of wavelengths.
NASA Astrophysics Data System (ADS)
Davis, Jeffery Jon
1998-09-01
The subject of this dissertation is the deformation process of a single metal - polymer system (titanium - polytetrafluoroethylene) and how this process leads to initiation of chemical reaction. Several different kinds of experiments were performed to characterize the behavior of this material to shock and impact. These mechanical conditions induce a rapid plastic deformation of the sample. All of the samples tested had an initial porosity which increased the plastic flow condition. It is currently believed that during the deformation process two important conditions occur: removal of the oxide layer from the metal and decomposition of the polymer. These conditions allow for rapid chemical reaction. The research from this dissertation has provided insight into the complex behavior of plastic deformation and chemical reactions in titanium - polytetrafluoroethylene (PTFE, Teflon). A hydrodynamic computational code was used to model the plastic flow for correlation with the results from the experiments. The results from this work are being used to develop an ignition and growth model for metal/polymer systems. Three sets of experiments were used to examine deformation of the 80% Ti and 20% Teflon materials: drop- weight, gas gun, and split-Hopkinson pressure bar. Recovery studies included post shot analysis of the samples using x-ray diffraction. Lagrangian hydrocode DYNA2D modeling of the drop-weight tests was performed for comparison with experiments. One of the reactions know to occur is Ti + C → TiC (s) which results in an exothermic release. However, the believed initial reactions occur between Ti and fluorine which produces TixFy gases. The thermochemical code CHEETAH was used to investigate the detonation products and concentrations possible during Ti - Teflon reaction. CHEETAH shows that the Ti - fluorine reactions are thermodynamically favorable. This research represents the most comprehensive to date study of deformation induced chemical reaction in metal/polymers.
Deeken, Corey R; Abdo, Michael S; Frisella, Margaret M; Matthews, Brent D
2011-01-01
For meshes to be used effectively for hernia repair, it is imperative that engineers and surgeons standardize the terminology and techniques related to physicomechanical evaluation of these materials. The objectives of this study were to propose standard techniques, perform physicomechanical testing, and classify materials commonly used for inguinal hernia repair. Nine meshes were evaluated: 4 polypropylene, 1 polyester, 1 polytetrafluoroethylene, and 3 partially absorbable. Physical properties were determined through image analysis, laser micrometry, and density measurements. Biomechanical properties were determined through suture retention, tear resistance, uniaxial, and ball burst testing with specimens tested in 2 different orientations. A 1-way ANOVA with Tukey's post-test or a t-test were performed, with p < 0.05. Significant differences were observed due to both mesh type and orientation. Areas of interstices ranged from 0.33 ± 0.01 mm² for ProLite (Atrium Medical Corp) and C-QUR Lite (Atrium Medical Corp) Large to 4.10 ± 0.06 mm² for ULTRAPRO (Ethicon), and filament diameters ranged from 99.00 ±8.1 μm for ProLite Ultra (Atrium Medical Corp) and C-QUR Lite Small to 338.8 ± 3.7 μm for Parietex Flat Sheet TEC (Covidien). These structural characteristics influenced biomechanical properties such as tear resistance and tensile strength. ProLite Ultra, C-QUR Lite Small, ULTRAPRO and INFINIT (WL Gore & Associates) did not resist tearing as effectively as the others. All meshes exhibited supraphysiologic burst strengths except INFINIT and ULTRAPRO. Significant differences exist between the physicomechanical properties of polypropylene, polyester, polytetrafluoroethylene, and partially absorbable mesh prostheses commonly used for inguinal hernia repair. Orientation of the mesh was also shown to be critical for the success of meshes, particularly those demonstrating anisotropy. Copyright © 2011 American College of Surgeons. Published by Elsevier Inc. All rights reserved.
Development of Nonelectronic Part Cyclic Failure Rates
1977-12-01
Schilling, W. A., "The User-Oriented Connector," Microwave Journal, Octcber 1976 40. Schneider, C., "Military Relay Reliability," Bell Telephone...polyimide B Diallyl phthalate, melamine , -55 to 200 fluorosilicone, silicone rubber, polysulfone, epoxy resin C Polytetrafluoroethylene (teflon) -55 to 125...propagation, solid state sciences, microwave physics and electronic reliability, maintainabilitg andcompatibility. .,% -UT104, , 8. g z
Towards the nonstick egg: designing fluorous proteins.
Neil, E; Marsh, G
2000-07-01
Anyone who has made scrambled eggs will have had cause to praise the properties of Teflon. Teflon's highly chemically inert and nonstick nature derives from the perfluorinated polymer polytetrafluoroethylene. Perfluorocarbons have unique and valuable physical properties not found in nature. By incorporating fluorine into proteins, it might be possible to produce biological molecules with novel and useful properties.
76 FR 29008 - Granular Polytetrafluoroethylene Resin From Italy; Correction of Notice of Scheduling
Federal Register 2010, 2011, 2012, 2013, 2014
2011-05-19
... Commission. ACTION: Notice. SUMMARY: In a notice published in the Federal Register May 12, 2011 (76 FR 27663), the Commission published a notice of scheduling of an expedited five-year review on an antidumping... notice is published pursuant to section 207.62 of the Commission's rules. By order of the Commission...
Ambient Observations of the Soot Aging Process during the SHARP Intensive Field Campaign
NASA Astrophysics Data System (ADS)
Reed, C.; Collins, D. R.; Khalizov, A. F.; Zheng, J.; Zhang, R.
2009-12-01
Soot aerosols affect climate both directly through absorption of solar radiation and indirectly by potentially serving as cloud condensation nuclei. Among the sources of uncertainty surrounding the effects of soot aerosol on the environment is the lack of scientific insight into the soot aging process, in which soot particles develop a coating of secondary species such as sulfates, ammonium, nitrate, and organics. Such processes may alter the behavior of soot by modifying particle morphology over time leading to changes in chemical, physical and scattering properties of the aerosol. However, it is often difficult to quantify such processes in the ambient environment due to the complex composition and spatial and temporal variability of the atmospheric aerosol. In order to better understand the effects of the environment on soot particles, it is desirable to study the processes responsible for their transformation in the ambient air without influence from variability in source region and history prior to sampling. To achieve this, the overall soot aging process in the ambient environment was physically isolated utilizing environmental chambers. Chamber measurements were conducted on the Moody Tower at the University of Houston using The Ambient Aerosol Chamber for Evolution Studies (AACES) during the SHARP campaign. AACES is a roughly cubical chamber constructed of a rigid acrylic outer shell, which transmits UV radiation both in the UV-B and UV-A ranges. FEP Teflon lines the inside of the chamber on all sides and the top, while expanded-PTFE (ePTFE) Teflon is used on the bottom of the chamber. The fibrous structure of the ePTFE acts as a barrier to particulates, while allowing gas molecules to move virtually unimpeded from the surrounding air into the chamber, creating an environment inside the chamber that is initially free of particles and continuously mimics the local ambient air. In order to study the effects of the soot aging process, a non-premixed propane flame was used to generate a polydisperse fresh soot aerosol. Then, using a differential mobility analyzer, a monodisperse, uncharged soot aerosol was injected into the environmental chamber. Observations of particle concentration, size, hygroscopicity, effective density, and light extinction and scattering properties were carried out over time using a tandem differential mobility analyzer system, an aerosol particle mass analyzer, a nephelometer and a cavity ringdown spectrometer. Results from preliminary analysis of the data collected during the campaign will be presented.
Janus droplets: liquid marbles coated with dielectric/semiconductor particles.
Bormashenko, Edward; Bormashenko, Yelena; Pogreb, Roman; Gendelman, Oleg
2011-01-04
The manufacturing of water droplets wrapped with two different powders, carbon black (semiconductor) and polytetrafluoroethylene (dielectric), is presented. Droplets composed of two hemispheres (Janus droplets) characterized by various physical and chemical properties are reported first. Watermelon-like striped liquid marbles are reported. Janus droplets remained stable on solid and liquid supports and could be activated with an electric field.
NASA Technical Reports Server (NTRS)
Aperlo, P. J. A.; Buck, P. A.; Weldon, V. A.
1981-01-01
In ball and socket joint where electrical insulator such as polytetrafluoroethylene is used as line to minimize friction, good electrical contact across joint may be needed for lightning protection or to prevent static-charge build-up. Electrical contact is maintained by ring of spring-loaded fingers mounted in socket. It may be useful in industry for cranes, trailers, and other applications requiring ball and socket joint.
Treatment of a coronary artery aneurysm by use of a covered stent graft – a case report
Gundoğdu, Fuat; Arslan, Sakir; Buyukkaya, Eyup; Senocak, Huseyin
2007-01-01
Coronary artery aneurysm is a rare finding at coronary angiography. Most coronary aneurysms remain asymptomatic. There is no consensus on its management; some advocate aggressive approach while others advocate conservative management. A case of coronary artery aneurysm successfully treated by implantation of a polytetrafluoroethylene-covered coronary stent is presented. PMID:22477247
Federal Register 2010, 2011, 2012, 2013, 2014
2011-05-17
... application, consult the Commission's Rules of Practice and Procedure, part 201, subparts A through E (19 CFR part 201), and part 207, subparts A, D, E, and F (19 CFR part 207). DATES: Effective Date: May 2, 2011... ), Office of Investigations, U.S. International Trade Commission, 500 E Street, SW., Washington, DC 20436...
NASA Technical Reports Server (NTRS)
Golub, Morton A.; Wydeven, Theodore; Cormia, Robert D.
1991-01-01
The presence of hydrocarbon contamination on the surface of polytetrafluoroethylene (PTFE) markedly affects the oxygen uptake, and hence the wettability, of this polymer when exposed to an oxygen plasma. As revealed by X-ray photoelectron spectroscopy (XPS) analysis, the oxygen-to-carbon ratio (O/C) for such a polymer can increase sharply, and correspondingly the fluorine-to-carbon ratio (F/C) can decrease sharply, at very short exposure times; at longer times, however, such changes in the O/C and F/C ratios reverse direction, and these ratios then assume values similar to those of the unexposed PTFE. The greater the extent of hydrocarbon contamination in the PTFE, the larger are the amplitudes of the 'spikes' in the O/C- and F/C-exposure time plots. In contrast, a pristine PTFE experiences a very small, monotonic increase of surface oxidation or O/C ratio with time of exposure to oxygen atoms, while the F/C ratio is virtually unchanged from that of the unexposed polymer (2.0). Unless the presence of adventitious hydrocarbon is taken into account, anomalous surface properties relating to polymer adhesion may be improperly ascribed to PTFE exposed to an oxygen plasma.
NASA Astrophysics Data System (ADS)
Long, Xiaoyun; He, Lifen; Zhang, Yan; Ge, Mingqiao
2018-04-01
In this study, the self-lubricating layer consist of polytetrafluoroethylene (PTFE) micropowders and two types fluorocarbon acrylate resin were formed on the surface of geotextile, to improves the evenness and decreases the frictional angle value of geotextile surface. The surface and cross section morphology of geotextile were examined by scanning electron microscopy (SEM). It was determined that composite resin emulsion was evenly coated on the surface of geotextile, to form a even and complete self-lubricating layer, and it was strongly combined with the geotextile due to formation of the transition layer. The tensile fracture stress and strain values of samples were evaluated by mechanical properties measurement, the tensile fracture stress of the untreated and treated sample was approximately 5329 kN/m and 5452 kN/m while the elongation at the yield of them was approximately 85% to 83.9%, respectively. In addition, the frictional angle values of municipal solid waste (MSW)/geotextile interface was measured by the tilt table test, the values of untreated sample was 28.1° and 24.2° under the dry and moist condition, the values of treated sample was 16.2° and 9.8°, respectively.
NASA Astrophysics Data System (ADS)
Mohammadian-Kohol, M.; Asgari, M.; Shakur, H. R.
2018-04-01
In this study, the effects of gamma radiation on the chemical structure, mechanical and optical properties of polytetrafluoroethylene (PTFE) sheet were investigated with various doses up to 12 kGy. The chemical changes in the structure were studied by FTIR spectroscopy. Also, effects of radiation on the different mechanical parameters such as Young's modulus, toughness, strain, and stress were studied at the maximum tolerable force and the fracture points. Furthermore, changing the various optical parameters such as absorption coefficient, Urbach energy, optical band gaps, refractive index, optical dispersion parameters and plasma resonance frequency were studied by UV-visible spectroscopy. Formation of a band at 1594 cm-1, which was belonged to double carbon bonds, indicated that chain-scission was occurred at 12 kGy gamma irradiation dose. As well, the mechanical results showed an increase in the elastic behavior of PTFE sheets and a decrease in the plastic behavior of it with absorbed dose increasing. Moreover, the results showed that gamma irradiation can effectively change the various optical properties of PTFE sheets due to different phenomena such as degradation of the main chains, occurring chain-scission, formation of free radicals and cross-linking in the polymer structure.
Wang, Shibo; Niu, Chengchao
2016-01-01
In this work, the plane-on-plane torsional fretting tribological behavior of polytetrafluoroethylene (PTFE) was studied. A model of a rigid, flat-ended punch acting on an elastic half-space was built according to the experimental conditions. The results indicate that the shape of T–θ curves was influenced by both the torsional angle and the normal load. The torsion friction torque and wear rate of PTFE exponentially decreased when the torsion angle rose. The torsional torque increased from 0.025 N·m under a normal load of 43 N to 0.082 N·m under a normal load of 123 N. With sequentially increasing normal load, the value of torque was maintained. With rising normal load, the wear mass loss of PTFE disks was increased and the wear rate was decreased. Good agreement was found with the calculated torque according to the model and the experimental torque except for that under a normal load of 163 N. The difference under a normal load of 163 N was caused by the coefficient of friction. Usually the coefficient of friction of a polymer decreases with increasing normal load, whereas a constant coefficient of friction was applied in the model. PMID:26799324
Kan, Hyo; Tsukagoshi, Kazuhiko
2017-07-01
Protein mixtures were separated using tube radial distribution chromatography (TRDC) in a polytetrafluoroethylene (PTFE) capillary (internal diameter=100µm) separation tube. Separation by TRDC is based on the annular flow in phase separation multiphase flow and features an open-tube capillary without the use of specific packing agents or application of high voltages. Preliminary experiments were conducted to examine the effects of pH and salt concentration on the phase diagram of the ternary mixed solvent solution of water-acetonitrile-ethyl acetate (8:2:1 volume ratio) and on the TRDC system using the ternary mixed solvent solution. A model protein mixture containing peroxidase, lysozyme, and bovine serum albumin was analyzed via TRDC with the ternary mixed solvent solution at various pH values, i.e., buffer-acetonitrile-ethyl acetate (8:2:1 volume ratio). Protein was separated on the chromatograms by the TRDC system, where the elution order was determined by the relation between the isoelectric points of protein and the pH values of the solvent solution. Copyright © 2017 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Destyorini, Fredina; Indriyati; Indayaningsih, Nanik; Prihandoko, Bambang; Zulfia Syahrial, Anne
2018-03-01
The carbon composite papers were produced by utilizing carbon materials from coconut coir. In the present work, carbon composite papers (CCP) were prepared by mixing carbon materials in the form of powder and fibre with polymer (ethylene vinyl acetate and polyethylene glycol) in xylene at 100°C. Then, polytetrafluoroethylene (PTFE) with different content was used to treat the surface of CCP. The properties of PTFE-coated CCP were analysed by means of contact angle measurement, tensile testing, porosity, density, and electrical conductivity measurements. As expected, all CCP’s surfaces treated with PTFE were found to be hydrophobic with contact angle >120° and relatively constant during 60 minutes measurement. Furthermore, water contact angle, density, and mechanical properties of CCP generally increase with increasing PTFE content. However, the porosity and electrical conductivity of CCP decrease slightly as the PTFE content increased from 0 wt% to 30 wt%. Based on the observation and analysis, the optimum PTFE content on CCP was 20 %, in which the mechanical properties and hydrophobicity behaviour were improved significantly, but it was only caused a very small drop in porosity and electrical conductivity
Light scattering of semitransparent sintered polytetrafluoroethylene films.
Li, Qinghe; Lee, Bong Jae; Zhang, Zhuomin M; Allen, David W
2008-01-01
Polytetrafluoroethylene (PTFE) is a strongly scattering material and has been regarded to have optical properties similar to biological tissues. In the present study, the bidirectional reflectance distribution function (BRDF) and the bidirectional transmittance distribution function (BTDF) of several PTFE films, with thicknesses from 0.11 to 10 mm, are measured using a laser scatterometer at the wavelength of 635 nm. The directional-hemispherical reflectance (R) and transmittance (T) were obtained by integrating BRDF and BTDF for normal incidence. Comparison of the ratio of the measured R and T with that calculated from the adding-doubling method allows the determination of the reduced scattering coefficient. Furthermore, the effect of surface scattering is investigated by measuring the polarization-dependent BRDF and BTDF at oblique incidence. By analyzing the measurement uncertainty of BTDF in the near-normal observation angles at normal incidence, the present authors found that the scattering coefficient of PTFE should exceed 1200 cm(-1), which is much greater than that of biological tissues. On the other hand, the absorption coefficient of PTFE must be less than 0.01 cm(-1), much smaller than that of biological tissues, a necessary condition to achieve R > or =0.98 with a 10-mm-thick slab.
Conformational and orientational order and disorder in solid polytetrafluoroethylene
NASA Astrophysics Data System (ADS)
Sprik, Michiel; Rothlisberger, Ursula; Klein, Michael L.
The low pressure phase diagram of solid polytetrafluoroethylene (PTFE/Teflon) has been investigated using constant temperature-constant pressure molecular dynamics techniques and a new all-atom potential model for fluorocarbons. The simulation was started in an ordered low temperature phase in which the molecules are parallel and have a helical conformation with a pitch of uniform magnitude and sign (chirality). In accordance with experiment, a transition to an orientationally disordered state is observed upon heating. The coherent helical winding of CF2 groups also disappears abruptly at the transition but short helical segments remain and become equally distributed between left and right chirality with increasing temperature. The orientational and conformational disorder is accompanied by translational diffusion along the chain direction. At a still higher temperature melting sets in. On cooling, the disordered solid phase is recovered and its structure is shown to be identical to that generated on heating. On further cooling, a spontaneous ordering transition is observed but the system fails to recover a uniform helical ground state. Instead, the high pressure ordered monoclinic all- trans (alkane-like) structure is obtained: an observation that indicates a deficiency in the potential model.
Computer Simulations of Polytetrafluoroethylene in the Solid State
NASA Astrophysics Data System (ADS)
Holt, D. B.; Farmer, B. L.; Eby, R. K.; Macturk, K. S.
1996-03-01
Force field parameters (Set I) for fluoropolymers were previously derived from MOPAC AM1 semiempirical data on model molecules. A second set (Set II) was derived from the AM1 results augmented by ab initio calculations. Both sets yield reasonable helical and phase II packing structures for polytetrafluoroethylene (PTFE) chains. However, Set I and Set II differ in the strength of van der Waals interactions, with Set II having deeper potential wells (order of magnitude). To differentiate which parameter set provides a better description of PTFE behavior, molecular dynamics simulations have been performed with Biosym Discover on clusters of PTFE chains which begin in a phase II packing environment. Added to the model are artificial constraints which allow the simulation of thermal expansion without having to define periodic boundary conditions for each specific temperature of interest. The preliminary dynamics simulations indicate that the intra- and intermolecular interactions provided by Set I are too weak. The degree of helical disorder and chain motion are high even at temperatures well below the phase II-phase IV transition temperature (19 C). Set II appears to yield a better description of PTFE in the solid state.
NASA Astrophysics Data System (ADS)
Herbold, E. B.; Nesterenko, V. F.; Benson, D. J.; Cai, J.; Vecchio, K. S.; Jiang, F.; Addiss, J. W.; Walley, S. M.; Proud, W. G.
2008-11-01
The variation of metallic particle size and sample porosity significantly alters the dynamic mechanical properties of high density granular composite materials processed using a cold isostatically pressed mixture of polytetrafluoroethylene (PTFE), aluminum (Al), and tungsten (W) powders. Quasistatic and dynamic experiments are performed with identical constituent mass fractions with variations in the size of the W particles and pressing conditions. The relatively weak polymer matrix allows the strength and fracture modes of this material to be governed by the granular type behavior of agglomerated metal particles. A higher ultimate compressive strength was observed in relatively high porosity samples with small W particles compared to those with coarse W particles in all experiments. Mesoscale granular force chains of the metallic particles explain this unusual phenomenon as observed in hydrocode simulations of a drop-weight test. Macrocracks forming below the critical failure strain for the matrix and unusual behavior due to a competition between densification and fracture in dynamic tests of porous samples were also observed. Numerical modeling of shock loading of this granular composite material demonstrated that the internal energy, specifically thermal energy, of the soft PTFE matrix can be tailored by the W particle size distribution.
2012-02-21
Testing and Materials °C Celsius DiEGME Diethylene Glycol Monomethyl Ether EPDM Ethylene Propylene Diene Monomer FARE Forward Area Refueling...urethane class AU, polyether urethane class EU, EPDM , Viton®, fluorosilicone class FQ, polytetrafluoroethylene (PTFE), polyolefin and polyester...sleeve Material not provided AAFARS 4720-00-540-1368 Hose, nonmetallic Material not provided AAFARS 4720-01-218-6958 Hose, preformed Rubber
Permeation Testing of Materials With Chemical Agents or Simulants (Swatch Testing)
2013-08-05
through a protective clothing material on a molecular level. Permeation involves the following: (1) sorption of molecules of the chemical into the...de Nemours and Company, Wilmington, Delaware), Teflon perfluoro- alkoxy ( PFA ), and Teflon polytetrafluoroethylene (PTFE). c. In all cases, only...pamphlet PCM positive control material PFA perfluoroalkoxy pH negative ion activity POL petroleum, oil, and lubricants PQL program quantification
Davidson, Anders J; Neff, Lucas P; Grayson, J Kevin; Clement, Nathan F; DeSoucy, Erik S; Simon Logan, Meryl A; Abbot, Christopher M; Sampson, James B; Williams, Timothy K
2017-09-01
The small diameter of temporary vascular shunts for vascular trauma management may restrict flow and result in ischemia or early thrombosis. We have previously reported a clinical experience with direct, open surgical reconstruction using expandable polytetrafluoroethylene stent grafts to create a "sutureless" anastomosis as an alternative to standard temporary vascular shunts. We sought to characterize patency and flow characteristics of these grafts compared with standard shunts in a survival model of porcine vascular injury. Twelve Yorkshire-cross swine received a 2-cm-long near-circumferential defect in the bilateral iliac arteries. A 14 Fr Argyle shunt was inserted into one randomly assigned artery, with a self-expanding expandable polytetrafluoroethylene stent deployed in the other. At 72 hours, conduit patency was evaluated by angiography. Arterial flow measurements were obtained at baseline, immediately after intervention, and after 72 hours via direct measurement with perivascular flow meters. Blood pressure proximal and distal to the conduits and arterial samples for histopathology were obtained during the terminal procedure. Angiography revealed no difference in patency at 72 hours (p = 1.0). While there was no difference in baseline arterial flow between arteries (p = 0.63), the stent grafts demonstrated significantly improved blood flow compared with shunts both immediately after intervention (390 ± 36 mL/min vs. 265 ± 25 mL/min, p = 0.002) and at 72 hours (261 ± 29 mL/min vs. 170 ± 36 mL/min, p = 0.005). The pressure gradient across the shunts was greater than that of the stent grafts (11.5 mm Hg [interquartile range, 3-19 mm Hg] vs. 3 mm Hg [interquartile range, 3-5 mm Hg], p = 0.013). The speed of deployment was similar between the two devices. Open "sutureless" direct site repair using commercially available stent grafts to treat vascular injury is a technically feasible strategy for damage control management of peripheral vascular injury and offers increased blood flow when compared with temporary shunts. Furthermore, stent grafts may offer improved durability to extend the window until definitive vascular repair. The combination of these traits may improve outcomes after vascular injury. Epidemiologic/Prognostic, level III.
NASA Astrophysics Data System (ADS)
Asiry, Moshabab A.; AlShahrani, Ibrahim; Almoammar, Salem; Durgesh, Bangalore H.; Kheraif, Abdulaziz A. Al; Hashem, Mohamed I.
2018-02-01
Aim. To investigate the effect of epoxy, polytetrafluoroethylene (PTFE) and rhodium surface coatings on surface roughness, nano-mechanical properties and biofilm adhesion of nickel titanium (Ni-Ti) archwires Methods. Three different coated (Epoxy, polytetrafluoroethylene (PTFE) and rhodium) and one uncoated Ni-Ti archwires were evaluated in the present study. Surface roughness (Ra) was assessed using a non-contact surface profilometer. The mechanical properties (nano-hardness and elastic modulus) were measured using a nanoindenter. Bacterial adhesion assays were performed using Streptococcus mutans (MS) and streptococcus sobrinus (SS) in an in-vitro set up. The data obtained were analyzed using analyses of variance, Tukey’s post hoc test and Pearson’s correlation coefficient test. Result. The highest Ra values (1.29 ± 0.49) were obtained for epoxy coated wires and lowest Ra values (0.29 ± 0.16) were obtained for the uncoated wires. No significant differences in the Ra values were observed between the rhodium coated and uncoated archwires (P > 0.05). The highest nano-hardness (3.72 ± 0.24) and elastic modulus values (61.15 ± 2.59) were obtained for uncoated archwires and the lowest nano-hardness (0.18 ± 0.10) and elastic modulus values (4.84 ± 0.65) were observed for epoxy coated archwires. No significant differences in nano-hardness and elastic modulus values were observed between the coated archwires (P > 0.05). The adhesion of Streptococcus mutans (MS) to the wires was significantly greater than that of streptococcus sobrinus (SS). The epoxy coated wires demonstrated an increased adhesion of MS and SS and the uncoated wires demonstrated decreased biofilm adhesion. The Spearman correlation test showed that MS and SS adhesion was positively correlated with the surface roughness of the wires. Conclusion. The different surface coatings significantly influence the roughness, nano-mechanical properties and biofilm adhesion parameters of the archwires. The evaluated parameters were most influenced by epoxy coating followed by PTFE and rhodium coating. A positive correlation was detected between surface roughness and biofilm adhesion.
The application of rapid prototyping technique in chin augmentation.
Li, Min; Lin, Xin; Xu, Yongchen
2010-04-01
This article discusses the application of computer-aided design and rapid prototyping techniques in prosthetic chin augmentation for mild microgenia. Nine cases of mild microgenia underwent an electrobeam computer tomography scan. Then we performed three-dimensional reconstruction and operative design using computer software. According to the design, we determined the shape and size of the prostheses and made an individualized prosthesis for each chin augmentation with the rapid prototyping technique. With the application of computer-aided design and a rapid prototyping technique, we could determine the shape, size, and embedding location accurately. Prefabricating the individual prosthesis model is useful in improving the accuracy of treatment. In the nine cases of mild microgenia, three received a silicone implant, four received an ePTFE implant, and two received a Medpor implant. All patients were satisfied with the results. During follow-up at 6-12 months, all patients remained satisfied. The application of computer-aided design and rapid prototyping techniques can offer surgeons the ability to design an individualized ideal prosthesis for each patient.
Direct glycerol fuel cell with polytetrafluoroethylene (PTFE) thin film separator
DOE Office of Scientific and Technical Information (OSTI.GOV)
Benipal, Neeva; Qi, Ji; Dalian Univ. of Technology, Dalian
Here, anion-exchange membrane-based direct glycerol fuel cells (AEM-DGFCs) can yield high power density, however challenges exist in developing chemically stable AEMs. Here, we demonstrate a porous PTFE thin film, a well-known chemical, electro-chemical, and thermal robust material that can serve as a separator between anode and cathode, thus achieving high DGFC’s performance. A simple aqueous-phase reduction method was used to prepare carbon nanotube supported PdAg nanoparticles (PdAg/CNT) with an average particle size of 2.9 nm. A DGFC using a PTFE thin film without any further modification with PdAg/CNT anode catalyst exhibits a peak power density of 214.7 mW cm –2more » at 80 °C, about 22.6% lower than a DGFC using a state-of-the-art AEM. We report a 5.8% decrease and 11.1% decrease in cell voltage for a PTFE thin film and AEM; similarly, the cell voltage degradation rate decreases from 1.2 to 0.8 mV h –1 for PTFE thin film, while for AEM, it decreases from 9.6 to 3.0 mV h –1 over an 80 h durability test period. Transmission electron microscopy results indicate that the average particle size of PdAg/CNT increases from 2.9 to 3.7 nm after 80 h discharge; this suggests that PdAg particle growth may be the main reason for the performance drop.« less
Direct glycerol fuel cell with polytetrafluoroethylene (PTFE) thin film separator
Benipal, Neeva; Qi, Ji; Dalian Univ. of Technology, Dalian; ...
2017-01-04
Here, anion-exchange membrane-based direct glycerol fuel cells (AEM-DGFCs) can yield high power density, however challenges exist in developing chemically stable AEMs. Here, we demonstrate a porous PTFE thin film, a well-known chemical, electro-chemical, and thermal robust material that can serve as a separator between anode and cathode, thus achieving high DGFC’s performance. A simple aqueous-phase reduction method was used to prepare carbon nanotube supported PdAg nanoparticles (PdAg/CNT) with an average particle size of 2.9 nm. A DGFC using a PTFE thin film without any further modification with PdAg/CNT anode catalyst exhibits a peak power density of 214.7 mW cm –2more » at 80 °C, about 22.6% lower than a DGFC using a state-of-the-art AEM. We report a 5.8% decrease and 11.1% decrease in cell voltage for a PTFE thin film and AEM; similarly, the cell voltage degradation rate decreases from 1.2 to 0.8 mV h –1 for PTFE thin film, while for AEM, it decreases from 9.6 to 3.0 mV h –1 over an 80 h durability test period. Transmission electron microscopy results indicate that the average particle size of PdAg/CNT increases from 2.9 to 3.7 nm after 80 h discharge; this suggests that PdAg particle growth may be the main reason for the performance drop.« less
Loehrer, Marco; Botterweck, Jens; Jahnke, Joachim; Mahlmann, Daniel M; Gaetgens, Jochem; Oldiges, Marco; Horbach, Ralf; Deising, Holger; Schaffrath, Ulrich
2014-07-01
Asian soybean rust (Phakopsora pachyrhizi) causes a devastating disease in soybean (Glycine max). We tested the hypothesis that the fungus generates high turgor pressure in its hyaline appressoria to mechanically pierce epidermal cells. Turgor pressure was determined by a microscopic technique, called transmitted light double-beam interference Mach-Zehnder microscopy (MZM), which was developed in the 1960s as a forefront of live cell imaging. We revitalized some original microscopes and equipped them for modern image capturing. MZM data were corroborated by cytorrhysis experiments. Incipient cytorrhysis determined the turgor pressure in appressoria of P. pachyrhizi to be equivalent to 5.13 MPa. MZM data revealed that osmotically active sugar alcohols only accounted for 75% of this value. Despite having a lower turgor pressure, hyaline rust appressoria were able to penetrate non-biodegradable polytetrafluoroethylene (PTFE) membranes more efficiently than do melanized appressoria of the anthracnose fungus Colletotrichum graminicola or the rice blast fungus Magnaporthe oryzae. Our findings challenge the hypotheses that force-based penetration is a specific hallmark of fungi differentiating melanized appressoria and that this turgor-driven process is solely caused by metabolic degradation products. The appressorial turgor pressure may explain the capability of P. pachyrhizi to forcefully invade a wide range of different plants and may pave the way to novel plant protection approaches. © 2014 The Authors. New Phytologist © 2014 New Phytologist Trust.
Butler, Caitlyn S; Nerenberg, Robert
2010-05-01
Microbial fuel cells (MFCs) can be built with layered electrode assemblies, where the anode, proton exchange membrane (PEM), and cathode are pressed into a single unit. We studied the performance and microbial community structure of MFCs with layered assemblies, addressing the effect of materials and oxygen crossover on the community structure. Four MFCs with layered assemblies were constructed using Nafion or Ultrex PEMs and a plain carbon cloth electrode or a cathode with an oxygen-resistant polytetrafluoroethylene diffusion layer. The MFC with Nafion PEM and cathode diffusion layer achieved the highest power density, 381 mW/m(2) (20 W/m(3)). The rates of oxygen diffusion from cathode to anode were three times higher in the MFCs with plain cathodes compared to those with diffusion-layer cathodes. Microsensor studies revealed little accumulation of oxygen within the anode cloth. However, the abundance of bacteria known to use oxygen as an electron acceptor, but not known to have exoelectrogenic activity, was greater in MFCs with plain cathodes. The MFCs with diffusion-layer cathodes had high abundance of exoelectrogenic bacteria within the genus Geobacter. This work suggests that cathode materials can significantly influence oxygen crossover and the relative abundance of exoelectrogenic bacteria on the anode, while PEM materials have little influence on anode community structure. Our results show that oxygen crossover can significantly decrease the performance of air-cathode MFCs with layered assemblies, and therefore limiting crossover may be of particular importance for these types of MFCs.
NASA Astrophysics Data System (ADS)
Deng, Nanping; Kang, Weimin; Ju, Jingge; Fan, Lanlan; Zhuang, Xupin; Ma, Xiaomin; He, Hongsheng; Zhao, Yixia; Cheng, Bowen
2017-04-01
The honeycomb-like hierarchical porous carbon nanofibers (PCNFs)-carbon nanotubes (CNTs)-sulfur(S) composite electrode is successfully desgined and prepared through ball-milling and heating method, in which the PCNFs are carbonized from fibers in the membrane composed of Polyvinyl Alcohol and Polytetrafluoroethylene by electro-blown spinning technology. The prepared PCNFs-CNTs-S composite are regarded as cathode for lithium-sulfur battery. The tailored porous structure and CNTs in the composite facilitate construction of a high electrical conductive pathway and store more S/polysulfides, and the dissoluble loss of intermediate S species in electrolyte can also be restrained because of acidized PVA-based porous carbon nanofibers. Meanwhile, the porous strcucture and CNTs can effectively alleviate volume changes in battery cycling process. Moreover, the presence of LiNO3 in electrolyte helps the electrochemical oxidation of Li2S and LiNO3-derived surface film effectively suppresses the migration of soluble polysulfide to the Li anode surface. Therefore, the obtained PCNFs-CNTs-S cathode exhibits excellent performance in Li-S battery with a high initial discharge capacity as high as 1302.9 mAh g-1, and super stable capacity retention with 809.1 mAh g-1 after 300 cycles at the current density of 837.5 mA g-1 (0.5 C). And the rate capability of PCNFs-CNTs-S electrode is much better than those of CNTs-S and PCNFs-S electrodes.
Gremmel, Christoph; Frömel, Tobias; Knepper, Thomas P
2016-10-01
Sixteen outdoor jackets were purchased in 2011/12 and analyzed for 23 different perfluoroalkyl and polyfluoroalkyl substances (PFASs). The jackets were selected based on their origin of production, price, market, and textile, such as polyester, nylon, polyamide, and content of poly(tetrafluoroethylene) membranes. Two robust analytical methods based on high pressure liquid chromatography combined with tandem mass spectrometry, as well as two liquid extractions, were developed enabling the analysis of PFASs with widely different physico-chemical properties. The jackets were found to contain PFASs in a range between 0.03 and 719 μg/m(2). Perfluorooctanoic acid (PFOA) was omnipresent (0.02-171 μg/m(2)), although at lower concentrations compared to the precursors of perfluoroalkyl carboxylic acids (PFCAs), namely fluorotelomer alcohols (FTOHs) (<0.001-698 μg/m(2)). Perfluoroalkane sulfonic acids and their putative precursors, in particular perfluoroalkane sulfonamides, were detected much less frequently at concentrations up to 5 μg/m(2). To determine the effect of the volatility of FTOHs, four selected jackets were stored in a sealed bag in the dark at room temperature and re-analyzed after 3.5 years. Only 10%-20% of the initial concentration of 8:2-FTOH and 20%-50% of 10:2-FTOH were found, whereas the concentrations of PFOA and perfluorodecanoic acid increased significantly. This supports the hypothesis that PFAS concentrations in textiles are also strongly dependent on age, and conditions of transport and storage. Copyright © 2016 Elsevier Ltd. All rights reserved.
Propagation of a Chemical Reaction through Heterogeneous Lithium- Polytetrafluoroethylene Mixtures
1975-12-11
Condensed Phases ........... ............... 9 1.2.1 Lithium-Gas Surface Reactions. .......... 10 1.2.2 Composite Solid Propellant Combustion. . .. 13...f:- the o:cu:=ence _A a surface reaction was developed, but no analyti7al reaction zate model was presented- 1.2.2 Composite S’-lid Propellant...Combustion Composite solid propellants are plastic-like materials consisting of small oxidizer particles embedded in a fuel matrix. Ammonium perchlorate is
Low-Thermal-Expansion Filled Polytetrafluoroethylene
NASA Technical Reports Server (NTRS)
Shapiro, Sanford S.
1989-01-01
PTFE made thermally compatible with aluminum without changing dielectric constant. Manufactured with fillers and pores to reduce coefficient of thermal expansion by factor of 6 to match aluminum. Material retains 2.1 dielectric constant of pure PTFE. Combines filler and micropore concepts. Particles and voids embedded in PTFE matrix function cooperatively. Particles take up compressive stress imposed by contracting PTFE, and voids take up expanding material. Increases dielectric constant, while voids reduce it.
Code of Federal Regulations, 2010 CFR
2010-07-01
....1.2) 46.2 mm diameter polytetrafluoroethylene (PTFE) filter for 24 hours using active sampling at... PM10 is performed on each individual 24-hour sample. Gravimetric mass analysis of PM10c filters is not... Pb in PM10 filters collected with the PM10c sampler. If these filters are analyzed for elements other...
Code of Federal Regulations, 2011 CFR
2011-07-01
....1.2) 46.2 mm diameter polytetrafluoroethylene (PTFE) filter for 24 hours using active sampling at... PM10 is performed on each individual 24-hour sample. Gravimetric mass analysis of PM10c filters is not... Pb in PM10 filters collected with the PM10c sampler. If these filters are analyzed for elements other...
Code of Federal Regulations, 2012 CFR
2012-07-01
....1.2) 46.2 mm diameter polytetrafluoroethylene (PTFE) filter for 24 hours using active sampling at... PM10 is performed on each individual 24-hour sample. Gravimetric mass analysis of PM10c filters is not... Pb in PM10 filters collected with the PM10c sampler. If these filters are analyzed for elements other...
Code of Federal Regulations, 2014 CFR
2014-07-01
....1.2) 46.2 mm diameter polytetrafluoroethylene (PTFE) filter for 24 hours using active sampling at... PM10 is performed on each individual 24-hour sample. Gravimetric mass analysis of PM10c filters is not... Pb in PM10 filters collected with the PM10c sampler. If these filters are analyzed for elements other...
Code of Federal Regulations, 2013 CFR
2013-07-01
....1.2) 46.2 mm diameter polytetrafluoroethylene (PTFE) filter for 24 hours using active sampling at... PM10 is performed on each individual 24-hour sample. Gravimetric mass analysis of PM10c filters is not... Pb in PM10 filters collected with the PM10c sampler. If these filters are analyzed for elements other...
NASA Astrophysics Data System (ADS)
Matos, Wladiana O.; Menezes, Eveline A.; Gonzalez, Mário H.; Costa, Letícia M.; Trevizan, Lilian C.; Nogueira, Ana Rita A.
2009-06-01
A procedure for partial digestion of bovine tissue is proposed using polytetrafluoroethylene (PTFE) micro-vessels inside a baby-bottle sterilizer under microwave radiation for multi-element determination by inductively coupled plasma optical emission spectrometry (ICP OES). Samples were directly weighed in laboratory-made polytetrafluoroethylene vessels. Nitric acid and hydrogen peroxide were added to the uncovered vessels, which were positioned inside the baby-bottle sterilizer, containing 500 mL of water. The hydrogen peroxide volume was fixed at 100 µL. The system was placed in a domestic microwave oven and partial digestion was carried out for the determination of Ca, Cu, Fe, Mg, Mn and Zn by inductively coupled plasma optical emission spectrometry. The single-vessel approach was used in the entire procedure, to minimize contamination in trace analysis. Better recoveries and lower residual carbon content (RCC) levels were obtained under the conditions established through a 2 4-1 fractional factorial design: 650 W microwave power, 7 min digestion time, 50 µL nitric acid and 50 mg sample mass. The digestion efficiency was ascertained according to the residual carbon content determined by inductively coupled plasma optical emission spectrometry. The accuracy of the proposed procedure was checked against two certified reference materials.
Improved Orifice Plate for Spray Gun
NASA Technical Reports Server (NTRS)
Cunningham, W.
1986-01-01
Erratic spray pattern of commercial spray gun changed to repeatable one by simple redesign of two parts. In modified spray gun orifice plate and polytetrafluoroethylene bushing redesigned to assure centering and alignment with nozzle. Such improvement useful in many industrial applications requiring repeatable spray patterns. Might include spraying of foam insulation, paint, other protective coatings, detergents, abrasives, adhesives, process chemicals, or fuels. Unmodified spray gun produces erratic spray because lateral misalignment between orifice plate and nozzle.
Review of LOX Bearing and Seal Materials Tester (BSMT) radial load system
NASA Technical Reports Server (NTRS)
Dufrane, K. F.; Kannel, J. W.
1984-01-01
Problems concerning the bearings in the high pressure oxygen turbopumps (HPOTP) were investigated. The tasks involved: failure analyses, bearing dynamics calculations, lubrication studies, wear studies, and analyses of thermal transients. The radial load system on MSFC's bearing and seal tester used to study components for the HPOTP in liquid oxygen (LOX) is analyzed and the wear behavior of AISI 440C steel with polytetrafluoroethylene (PTFE) lubrication is studied.
1995-03-15
billion volume ppm parts per million PT pole-mounted PTFE polytetrafluoro-ethylene PUF polyurethane foam PVC polyvinyl chloride QA quality assurance...and Illinois Environmental Protection Agency (IEPA) quality assurance (QA) objectives. The format of the OQAPP is based on "Interim Guidelines and...County. The till material deposited in the Fort Sheridan region has been classified as the Wadsworth Till Member of the Wedron Formation . This till
Ion beam sputter etching and deposition of fluoropolymers
NASA Technical Reports Server (NTRS)
Banks, B. A.; Sovey, J. S.; Miller, T. B.; Crandall, K. S.
1978-01-01
Fluoropolymer etching and deposition techniques including thermal evaporation, RF sputtering, plasma polymerization, and ion beam sputtering are reviewed. Etching and deposition mechanism and material characteristics are discussed. Ion beam sputter etch rates for polytetrafluoroethylene (PTFE) were determined as a function of ion energy, current density and ion beam power density. Peel strengths were measured for epoxy bonds to various ion beam sputtered fluoropolymers. Coefficients of static and dynamic friction were measured for fluoropolymers deposited from ion bombarded PTFE.
Corrosion Chemistry in Inhibited HDA.
1980-11-30
mg HF. 200 B.1 Teflon PFA Reactor 201 (xviii) .. .. - i LIST OF MICROGRAPHS Micrograph Follows Page 4.1 A1/HDA x 1,000 80 4.2 A1/0.4 Wt % PF5 x 2,000...Ethylene Propylene copolymer Teflon PTFE Polytetrafluoroethylene Teflon PFA Perfluoroalkoxy fluorocarbon resin Spectroscopy IR (ir) Infra-red UV...fluoroplastic apparatus (to avoid any possible contamination by the reaction products of HF with glass). Iron powder (0.3g) was placed in a PFA screw-cap
Comparison of the reflectance characteristics of polytetrafluoroethylene and barium sulfate paints
NASA Technical Reports Server (NTRS)
Butner, C. L.; Schutt, J. B.; Shai, M. C.
1984-01-01
Preliminary results are presented of the directional reflectance measurements taken on two tetrafluorethylene (TFE) paints formulated with silicone binders. Both paints are found to be more Lambertian than barium sulfate paint and pressed powder, although the pigment to binder ratios for barium sulfate and TFE paints are about 133 and 3.3 to 1, respectively. The TFE paints exhibit total visible reflectances above 90 percent and offer surfaces that are not significantly affected by water.
Infrared Complex Optical Constants of GB, GF, HD, HN1, and VX
2014-04-01
amplitude ratio, Psi (), and the phase difference induced by the reflection, Delta (). These Stainless steel holder Liquid IR source polarizer S...required with a transmission technique. 2.3 ATR IR-VASE Liquid-Sampling Assembly The ATR liquid-sampling assembly consisted of a stainless steel cell...cell body with a stainless steel bar that was held in place with screws and aluminum shims at either end of the bar. A 0.1 mm polytetrafluoroethylene
NASA Astrophysics Data System (ADS)
Peng, Shiguang; Guo, Yue; Xie, Guoxin; Luo, Jianbin
2018-05-01
This study compares the tribological performance of polytetrafluoroethylene (PTFE) thin film coating reinforced with black phosphorus (BP) or ball-milled graphite (BMG) nanoparticles, so as to elucidate their mechanism of action under reciprocating sliding test conditions. PTFE coatings with 0.5 wt.% BMG (BMG/PTFE) and 0.5 wt.% BP (BP/PTFE) were prepared on GCr15 bearing steel disk by using a spin coater. The friction and wear tests were carried out by using the ball-on-disk tribometer under a normal load of 1 N (contact pressure: 780 MPa), a frequency of 2 Hz, and 4.2 mm sliding displacement amplitude. The surface roughness, wear volume and surface morphology of the coatings were characterized by the three-dimensional white light, and Energy Dispersive X-ray Detector (EDX) analysis coupled with environmental scanning electron microscope (ESEM). It is found that BP/PTFE coating has better anti-wear and anti-friction performances than those of pure PTFE or BMG/PTFE coating. The coating with BP nanoparticles shows excellent tribological properties with the wear volume decreased from 3.52 × 106 μm3 to 1.64 × 106 μm3 and the coefficient of friction (COF) decreased from 0.117 to 0.046. More importantly, the BP layer probably expands and absorbs much energy due to its negative Poisson's ratio phenomenon under reciprocating sliding, and effectively reducing furrow and adhesive wear.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang, Liu; Liu, Jinxu, E-mail: liujinxu@bit.edu.cn; Zhang, Xinbo
2015-11-15
Energetic structural material is a kind of materials that are inert under normal conditions but could produce exothermic chemical reaction when subjected to impact. This report shows a kind of energetic structural material of tungsten (W)-polytetrafluoroethylene (PTFE)-aluminum (Al) with density of 4.12 g/cm{sup 3}, excellent ductility and dynamic compressive strength of 96 MPa. Moreover, 50W-35PTFE-15Al (wt%) can exhibit a high reaction energy value of more than 2 times of TNT per unit mass and 5 times of TNT per unit volume, respectively, but with excellent insensitivity compared with traditional explosives. Under thermal conditions, the W-PTFE-Al composite can keep stable atmore » 773 K. Under impact loading, when the strain rate up to ∼4820 s{sup −1} coupled with the absorbed energy per unit volume of 120 J/cm{sup 3}, deflagration occurs and combustion lasts for 500 μs. During impact compressive deformation, the PTFE matrix is elongated into nano-fibers, thus significantly increases the reaction activity of W-PTFE-Al composites. The nano-fiber structure is necessary for the reaction of W-PTFE-Al composites. The formation of PTFE nano-fibers must undergo severe plastic deformation, and therefore the W-PTFE-Al composites exhibit excellent insensitivity and safety. Furthermore, the reaction mechanisms of W-PTFE-Al composites in argon and in air are revealed.« less
Lee, Jinah; Duy, Pham Khac; Yoon, Jihye; Chung, Hoeil
2014-06-21
A bead-incorporated transmission scheme (BITS) has been demonstrated for collecting reproducible transmission near-infrared (NIR) spectra of samples with inconsistent shapes. Isotropically diffused NIR radiation was applied around a sample and the surrounding radiation was allowed to interact homogeneously with the sample for transmission measurement. Samples were packed in 1.40 mm polytetrafluoroethylene (PTFE) beads, ideal diffusers without NIR absorption, and then transmission spectra were collected by illuminating the sample-containing beads using NIR radiation. When collimated radiation was directly applied, a small portion of the non-fully diffused radiation (NFDR) propagated through the void space of the packing and eventually degraded the reproducibility. Pre-diffused radiation was introduced by placing an additional PTFE disk in front of the packing to diminish NFDR, which produced more reproducible spectral features. The proposed scheme was evaluated by analyzing two different solid samples: density determination for individual polyethylene (PE) pellets and identification of mining locality for tourmalines. Because spectral collection was reproducible, the use of the spectrum acquired from one PE pellet was sufficient to accurately determine the density of nine other pellets with different shapes. The differentiation of tourmalines, which are even more dissimilar in appearance, according to their mining locality was also feasible with the help of the scheme.
NASA Astrophysics Data System (ADS)
Hopp, B.; Kresz, N.; Kokavecz, J.; Smausz, T.; Schieferdecker, H.; Döring, A.; Marti, O.; Bor, Z.
2004-01-01
In the present paper, we report an experimental determination of adhesive and topographic characteristics of chemically modified surface of polytetrafluoroethylene (PTFE) films. The surface chemistry was modified by ArF excimer laser irradiation in presence of triethylene-tetramine photoreagent. The applied laser fluence was varied in the range of 0.4-9 mJ/cm 2, and the number of laser pulses incident on the same area was 1500. To detect the changes in the adhesive features of the treated Teflon samples, we measured receding contact angle for distilled water and adhesion strength, respectively. It was found that the receding contact angle decreased from 96° to 30-37° and the adhesion strength of two-component epoxy glue to the treated sample surface increased from 0.03 to 9 MPa in the applied laser fluence range. Additionally, it was demonstrated that the adhesion of human cells to the modified Teflon samples is far better than to the untreated ones. The contact mode and pulsed force mode atomic force microscopic investigations of the treated samples demonstrated that the measured effective contact area of the irradiated films does not differ significantly from that of the original films, but the derived adhesion force is stronger on the modified samples than on the untreated ones. Hence, the increased adhesion of the treated Teflon films is caused by the higher surface energy.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yang, Lei; School of Astronautics, Beihang University, Beijing 100191; Zeng, Guangshang
2016-07-15
Wall–plasma interactions excited by ablation controlled arcs are very critical physical processes in pulsed plasma thrusters (PPTs). Their effects on the ionization processes of ablated vapor into discharge plasma directly determine PPT performances. To reveal the physics governing the ionization phenomena in PPT discharge, a modified model taking into account the pyrolysis effect of heated polytetrafluoroethylene propellant on the wall–plasma interactions was developed. The feasibility of the modified model was analyzed by creating a one-dimensional simulation of a rectangular ablative PPT. The wall–plasma interaction results based on this modified model were found to be more realistic than for the unmodifiedmore » model; this reflects the dynamic changes of the inflow parameters during discharge in our model. Furthermore, the temporal and spatial variations of the different plasma species in the discharge chamber were numerically studied. The numerical studies showed that polytetrafluoroethylene plasma was mainly composed of monovalent ions; carbon and fluorine ions were concentrated in the upstream and downstream discharge chamber, respectively. The results based on this modified model were in good agreement with the experimental formation times of the various plasma species. A large number of short-lived and highly ionized carbon and fluorine species (divalent and trivalent ions) were created during initial discharge. These highly ionized species reached their peak density earlier than the singly ionized species.« less
Does vascular stapling improve compliance of vascular anastomoses?
Stansby, G; Knez, P; Berwanger, C S; Nelson, K; Reichert, V; Schmitz-Rixen, T
2001-01-01
Elastic properties of vessel walls are altered by vascular anastomoses. Such alterations may lead to neointimal hyperplasia, which is a common cause of reocclusion following vascular surgery. The severity of paraanastomotic hypercompliant zones and anastomotic compliance drop depend on suturing material and on elastic properties of the anastomotic vessel segments. This study compares paraanastomotic hypercompliance and anastomotic compliance drop when using a new vascular closure system (VCS) and a conventional, continuous suture line in the preparation of end-to-end anastomoses. Compliance of artery-artery, vein-artery, and polytetrafluoroethylene-artery anastomoses was measured in an artificial circulation system at mean pressures of 60, 90, and 120 mm Hg, comparing conventional suturing and the VCS. When using the VCS for vein-artery anastomoses, significantly less postanastomotic hypercompliance was achieved at mean pressures of 60 mm Hg (14.2 +/-3.8% above remote postanastomotic area), compared to suture (55.1 +/-14.8%, p<0.05). At 90 mm Hg, respective values were 11.0 +/-2.3% for VCS and 54.7 +/-10.1% for suture, p<0.01. At 120 mm Hg, in polytetrafluoroethylene-artery anastomoses, the anastomotic compliance drop was significantly less when using the continuous suture line (93.9 +/-1.1% below remote postanastomotic compliance), compared to VCS (97.2 +/-0.2%, p<0.05). Compared to conventional suturing, use of the VCS reduced postanastomotic hypercompliance in vein-artery anastomoses.
On the surface trapping parameters of polytetrafluoroethylene block
NASA Astrophysics Data System (ADS)
Zhang, Guan-Jun; Yang, Kai; Zhao, Wen-Bin; Yan, Zhang
2006-12-01
Surface flashover phenomena under high electric field are closely related to the surface characteristics of a solid insulating material between energized electrodes. Based on measuring the surface potential decaying curve of polytetrafluoroethylene (PTFE) block charged by a needle-plane corona discharge, its surface trapping parameters are calculated with the isothermal current theory, and the correlative curve between the surface trap density and its energy level is obtained. The maximum density of electron traps and hole traps in the surface layer of PTFE presents a similar value of ∼2.7 × 1017 eV-1 m-3, and the energy level of its electron and hole traps is of about 0.85-1.0 eV and 0.80-0.90 eV, respectively. Via the X-ray photoelectron spectroscopy (XPS) technique, the F, C, K and O elements are detected on the surface of PTFE samples, and F shows a remarkable atom proportion of ∼73.3%, quite different from the intrinsic distribution corresponding to its chemical formula. The electron traps are attributed to quantities of F atoms existing on the surface of PTFE due to its molecular chain with C atoms surrounded by F atoms spirally. It is considered that the distortions of chemical and electronic structure on solid surface are responsible for the flashover phenomena occurring at a low applied voltage.
DeNicolo, Philip J; Guyton, M Kelly; Cuenin, Michael F; Hokett, Steven D; Sharawy, Mohamed; Borke, James; McPherson, James C
2015-10-01
Platelet-rich plasma (PRP) is an autogenous source of growth factors shown to facilitate human bone growth. Bio-Oss, an osteoconductive xenograft, is used clinically to regenerate periodontal defects, restore dental alveolar ridges, and facilitate sinus-lift procedures. The purpose of this study was to analyze whether a combination of PRP and Bio-Oss would enhance bone regeneration better than either material alone. PRP and/or Bio-Oss were administered in an 8-mm critical-size defect (CSD) rat calvarial model of bone defect between 2 polytetrafluoroethylene membranes to prevent soft tissue incursion. Eight weeks after the induction of the CSD, histologic sections were stained with hematoxylin and eosin stain and analyzed via light microscopy. Qualitative analyses revealed new bone regeneration in all 4 groups. The Bio-Oss and PRP plus Bio-Oss groups demonstrated greater areas of closure in the defects than the control or PRP-only groups because of the space-maintaining ability of Bio-Oss. The groups grafted with Bio-Oss showed close contact with new bone growth throughout the defects, suggesting a stronger graft. The use of PRP alone or in combination with Bio-Oss, however, did not appear to enhance osseous regeneration at 8 weeks. Areas grafted with Bio-Oss demonstrated greater space-maintaining capacity than controls, and PRP was an effective vehicle for placement of the Bio-Oss. However, at 8 weeks this study was unable to demonstrate a significant advantage of using PRP plus Bio-Oss over using Bio-Oss alone.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Panin, S. V., E-mail: svp@ispms.tsc.ru; Kornienko, L. A.; Poltaranin, M. A.
2014-11-14
In order to compare effectiveness of adding solid lubricating fillers for polymeric composites based on ultra-high molecular weight polyethylene (UHMWPE) with graphite, molybdenum disulfide and polytetrafluoroethylene, their tribotechnical characteristics under dry friction, boundary lubrication and abrasive wearing were investigated. The optimal weight fractions of fillers in terms of improving wear resistance have been determined. The supramolecular structure and topography of wear track surfaces of UHMWPE-based composites with different content of fillers have been studied.
Method of radiation degradation of PTFE under vacuum conditions
NASA Astrophysics Data System (ADS)
Korenev, Sergey
2004-09-01
A new method of radiation degradation of Polytetrafluoroethylene (PTFE) under vacuum conditions is considered in this report. The combination of glow gas discharge and electrical surface discharge (on surface and inside PTFE) increases the efficiency of thermal-radiation degradation. The main mechanism of this degradation method consists of the breaking of C-C and C-F bonds. The vacuum conditions allow decreasing of the concentration of toxic compounds, such as a HF. Experimental results for degradation of PTFE are presented.
High-Performance Water-Iodinating Cartridge
NASA Technical Reports Server (NTRS)
Sauer, Richard; Gibbons, Randall E.; Flanagan, David T.
1993-01-01
High-performance cartridge contains bed of crystalline iodine iodinates water to near saturation in single pass. Cartridge includes stainless-steel housing equipped with inlet and outlet for water. Bed of iodine crystals divided into layers by polytetrafluoroethylene baffles. Holes made in baffles and positioned to maximize length of flow path through layers of iodine crystals. Resulting concentration of iodine biocidal; suppresses growth of microbes in stored water or disinfects contaminated equipment. Cartridge resists corrosion and can be stored wet. Reused several times before necessary to refill with fresh iodine crystals.
Formation of protective composite coatings with the use of SPTFE suspensions
NASA Astrophysics Data System (ADS)
Nadaraia, K. V.; Mashtalyar, D. V.; Sinebryukhov, S. L.; Gnedenkov, S. V.
2017-09-01
The method of protective composite coatings formation with the use of the plasma electrolytic oxidation (PEO) and subsequent treatment in isopropanol or aqueous suspension of the superdispersed polytetrafluoroethylene (SPTFE) have been developed. Morphological, electrochemical and tribological studies, as well as wetting ability of the protective coatings have been carried out. The obtained results corroborated the increase of the corrosion and wear resistance parameters for the polymer-containing coating in comparison with the base PEO-coating and uncoated material.
Barrow, C S; Lucia, H; Stock, M F; Alarie, Y
1979-05-01
The physiological stress imposed upon mice due to the irritating properties of thermal decomposition products of polymeric materials was evaluated. Acute lethality and histopathological evaluation were included in the study. The rankings of the polymeric materials studied from most to least hazardous was concluded to be polytetrafluoroethylene greater than polyvinyl chloride greater than Douglas Fir and flexible polyurethane foam greater than fiber glass reinforced polyester greater than copper coated wire with mineral insulation.
Dendrite preventing separator for secondary lithium batteries
NASA Technical Reports Server (NTRS)
Shen, David H. (Inventor); Surampudi, Subbarao (Inventor); Huang, Chen-Kuo (Inventor); Halpert, Gerald (Inventor)
1993-01-01
Dendrites are prevented from shorting a secondary lithium battery by use of a first porous separator, such as porous polypropylene, adjacent to the lithium anode that is unreactive with lithium and a second porous fluoropolymer separator between the cathode and the first separator, such as polytetrafluoroethylene, that is reactive with lithium. As the tip of a lithium dendrite contacts the second separator, an exothermic reaction occurs locally between the lithium dendrite and the fluoropolymer separator. This results in the prevention of the dendrite propagation to the cathode.
Dendrite preventing separator for secondary lithium batteries
NASA Technical Reports Server (NTRS)
Shen, David H. (Inventor); Surampudi, Subbarao (Inventor); Huang, Chen-Kuo (Inventor); Halpert, Gerald (Inventor)
1995-01-01
Dendrites are prevented from shorting a secondary lithium battery by use of a first porous separator such as porous polypropylene adjacent the lithium anode that is unreactive with lithium and a second porous fluoropolymer separator between the cathode and the first separator such as polytetrafluoroethylene that is reactive with lithium. As the tip of a lithium dendrite contacts the second separator, an exothermic reaction occurs locally between the lithium dendrite and the fluoropolymer separator. This results in the prevention of the dendrite propagation to the cathode.
Granulated lead oxides with teflon
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nilsson, O.
An improvement in the production of tube electrodes for lead storage batteries comprising mixing a small amount (0.1 to 3 weight percent) of polytetrafluoroethylene (Ptfe) with lead powder, the mixture is heated and shear stresses are applied thereto sufficient to convert substantially all of the ptfe in the mixture to fibrous form and to form a non-powdery dough. The dough is then granulated and the doughy granules about 100 mu to 500 mu in major dimension are used for filling tube elctrodes a lead-acid storage battery.
A simple device for exteriorizing chronically implanted catheters in dogs.
Butterfield, J L; Decker, G E
1984-04-01
A device, consisting of a round base and cap made of polytetrafluoroethylene, was made to exteriorize and protect chronically implanted arterial and venous catheters in conscious dogs. In experiments lasting as long as 9 months, the subcutaneously implanted button-like appliance did not cause tissue reactions and was well tolerated by 98% of a group of 200 dogs. Being maintenance-free, having the capacity to exteriorize several catheter or wire outputs, and needing no protective harness were advantages of the device.
Compressive Properties of Extruded Polytetrafluoroethylene
2007-07-01
against equivalent temperature ( Tmap ) at a single strain rate (3map). This is a pragmatic, empirically based line- arization and extension to large strains...one of the strain rates that was used in the experimental program, and in this case two rates were used: 0.1 s1 and 3200 s1. The value Tmap , is...defined as Tmap ¼ Texp þA log _3map log _3exp ð11Þ where the subscript exp indicates the experimental values of strain rate and temperature. A
Diffusely Reflecting Paints Containing TFE
NASA Technical Reports Server (NTRS)
Shai, M. C.; Schutt, J. B.
1985-01-01
Highly reflective, diffused coatings developed by incorporating polytetrafluoroethylene (TFE) pigment with alcohol-soluble binders. Alcohol and binder mixed together in blender before adding TFE. TFE preferably outgassed in mechanical-pump vacuum for typical interval of 4 hours before adding to liquid. Like wetting agent, vacuum treatment helps to prevent clumping of TFE and eases dispersion throughout mixture. Mixture blended for 3 to 5 minutes before used. Coatings useful on reflectance-standard surfaces for calibrating radiometric instruments in both laboratory and field. Paints washable and usable as optical reference surfaces.
Finger-Circumference-Measuring Device
NASA Technical Reports Server (NTRS)
Le, Suy
1995-01-01
Easy-to-use device quickly measures circumference of finger (including thumb) on human hand. Includes polytetrafluoroethylene band 1/8 in. wide, bent into loop and attached to tab that slides on scale graduated in millimeters. Sliding tab preloaded with constant-force tension spring, which pulls tab toward closure of loop. Designed to facilitate measurements at various points along fingers to obtain data for studies of volumetric changes of fingers in microgravity. Also used in normal Earth gravity studies of growth and in assessment of diseases like arthritis.
Liu, Cong; Li, Yanqing; Liao, Ruijin; Liao, Qiang; Tang, Chao
2018-01-01
Cellulose insulation polymer is an important component of oil-paper insulation, which is widely used in power transformer. The weight of the cellulose insulation polymer materials is as high as tens of tons in the larger converter transformer. Excellent performance of oil-paper insulation is very important for ensuring the safe operation of larger converter transformer. An effective way to improve the insulation and the physicochemical property of the oil impregnated insulation pressboard/paper is currently a popular research topic. In this paper, the polytetrafluoroethylene (PTFE) functional film was coated on the cellulose insulation pressboard by radio frequency (RF) magnetron sputtering to improve its breakdown voltage and the hydrophobicity properties. X-ray photoelectron spectroscopy (XPS) results show that the nano-structure PTFE functional film was successfully fabricated on the cellulose insulation pressboard surface. The scanning electron microscopy (SEM) and X-ray diffraction (XRD) present that the nanoscale size PTFE particles were attached to the pressboard surface and it exists in the amorphous form. Atomic force microscopy (AFM) shows that the sputtered pressboard surface is still rough. The rough PTFE functional film and the reduction of the hydrophilic hydroxyl of the surface due to the shielding effect of PTFE improve the breakdown and the hydrophobicity properties of the cellulose insulation pressboard obviously. This paper provides an innovative way to improve the performance of the cellulose insulation polymer. PMID:29883376
Hao, Jian; Liu, Cong; Li, Yanqing; Liao, Ruijin; Liao, Qiang; Tang, Chao
2018-05-21
Cellulose insulation polymer is an important component of oil-paper insulation, which is widely used in power transformer. The weight of the cellulose insulation polymer materials is as high as tens of tons in the larger converter transformer. Excellent performance of oil-paper insulation is very important for ensuring the safe operation of larger converter transformer. An effective way to improve the insulation and the physicochemical property of the oil impregnated insulation pressboard/paper is currently a popular research topic. In this paper, the polytetrafluoroethylene (PTFE) functional film was coated on the cellulose insulation pressboard by radio frequency (RF) magnetron sputtering to improve its breakdown voltage and the hydrophobicity properties. X-ray photoelectron spectroscopy (XPS) results show that the nano-structure PTFE functional film was successfully fabricated on the cellulose insulation pressboard surface. The scanning electron microscopy (SEM) and X-ray diffraction (XRD) present that the nanoscale size PTFE particles were attached to the pressboard surface and it exists in the amorphous form. Atomic force microscopy (AFM) shows that the sputtered pressboard surface is still rough. The rough PTFE functional film and the reduction of the hydrophilic hydroxyl of the surface due to the shielding effect of PTFE improve the breakdown and the hydrophobicity properties of the cellulose insulation pressboard obviously. This paper provides an innovative way to improve the performance of the cellulose insulation polymer.
Huang, Kang; Goddard, Julie M
2015-09-01
Application of nonfouling coatings on thermal processing equipment can improve operational efficiency. However, to enable effective commercial translation, a need exists for more comprehensive studies on the stability of nonfouling coatings after exposure to different sanitizers. In the current study, the influence of different commercial dairy equipment sanitizers on the nonfouling properties of stainless steel modified with electroless Ni-polytetrafluoroethylene (PTFE) coatings was determined. Surface properties, such as dynamic contact angle, surface energy, surface morphology, and elemental composition, were measured before and after the coupons were exposed to the sanitizers for 168 cleaning cycles. The fouling behavior of Ni-PTFE-modified stainless steel coupons after exposure was also evaluated by processing raw milk on a self-fabricated benchtop-scale plate heat exchanger. The results indicated that peroxide sanitizer had only minor effect on the Ni-PTFE-modified stainless steel surface, whereas chlorine- and iodine-based sanitizers influenced the surface properties drastically. The coupons after 168 cycles of exposure to peroxide sanitizer accumulated the least amount of fouling material (4.44±0.24mg/cm(2)) compared with the coupons exposed to the other 3 sanitizers. These observations indicated that the Ni-PTFE nonfouling coating retained antifouling properties after 168 cycles of exposure to peroxide-based sanitizer, supporting their potential application as nonfouling coatings for stainless steel dairy processing equipment. Copyright © 2015 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Feddes, B.; Wolke, J. G. C.; Jansen, J. A.; Vredenberg, A. M.
2003-03-01
Calcium phosphate (CaP) coatings can be applied to improve the biological performance of polymeric medical implants. A strong interfacial bond between ceramic and polymer is required for clinical applications. Because the chemical structure of an interface plays an important role in the adhesion of a coating, we studied the formation of the interface between CaP and polystyrene (PS) and polytetrafluoroethylene (PTFE). The coating was deposited in a radio frequency (rf) magnetron sputtering deposition system. Prior to the deposition, some samples received an oxygen plasma pretreatment. We found that the two substrates show a strongly different reactivity towards CaP. On PS a phosphorus and oxygen enrichment is present at the interface. This is understood from POx complexes that are able to bind to the PS. The effects of the plasma pretreatment are overruled by the deposition process itself. On PTFE, a calcium enrichment and an absence of phosphorus is found at the interface. The former is the result of CaF2-like material being formed at the interface. The latter may be the result of phosphorus reacting with escaping fluorine to a PF3 molecule, which than escapes from the material as a gas molecule. We found that the final structure of the interface is mostly controlled by the bombardment of energetic particles escaping either from the plasma or from the sputtering target. The work described here can be used to understand and improve the adhesion of CaP coatings deposited on medical substrates.
NASA Astrophysics Data System (ADS)
Wang, Haiyan; Wang, Weizong; Yan, Joseph D.; Qi, Haiyang; Geng, Jinyue; Wu, Yaowu
2017-10-01
Ablation-controlled plasmas have been used in a range of technical applications where local thermodynamic equilibrium (LTE) is often violated near the wall due to the strong cooling effect caused by the ablation of wall materials. The thermodynamic and transport properties of ablated polytetrafluoroethylene (PTFE) vapor, which determine the flowing plasma behavior in such applications, are calculated based on a two-temperature model at atmospheric pressure. To our knowledge, no data for PTFE have been reported in the literature. The species composition and thermodynamic properties are numerically determined using the two-temperature Saha equation and the Guldberg-Waage equation according to van de Sanden et al’s derivation. The transport coefficients, including viscosity, thermal conductivity and electrical conductivity, are calculated with the most recent collision interaction potentials using Devoto’s electron and heavy-particle decoupling approach but expanded to the third-order approximation (second-order for viscosity) in the frame of the Chapman-Enskog method. Results are computed for different degrees of thermal non-equilibrium, i.e. the ratio of electron to heavy-particle temperatures, from 1 to 10, with electron temperature ranging from 300 to 40 000 K. Plasma transport properties in the LTE state obtained from the present work are compared with existing published results and the causes for the discrepancy analyzed. The two-temperature plasma properties calculated in the present work enable the modeling of wall ablation-controlled plasma processes.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Baohui Xu; Jiusun Zhang; Guaogeng Mao
1992-07-01
Fluoropolymers are widely used in thermal and electrical industries. Polytetrafluoroethylene (PTFE) plastic is a typical one. During its production, workers are occupationally exposed to many organic fluorides, especially tetrafluoroethylene, chlorodifluoromethane, PTFE and its thermal decomposition products. Of these compounds, it has been documented that following inhalation of combustion products of PTFE the focal hemorrhages, edema, fibrin deposition in lungs and renal infarcts were observed in rats. Odum and Green have demonstrated a marked damage to proximal tubule of kidney with no effects on the liver in rats exposed to 6000 ppm tetrafluoroethylene for 6 hr. The investigations of the hazardsmore » of these compounds to workers have been mainly focused on acute toxicity. There have been some reports that polymers and its pyrolysis caused polymer fume fever and pulmonary edema. In practice, workers engaged in PTFE manufacture are chronically exposed to the above-mentioned chemicals, but little was known about the hazards ascribed to these chemicals. To clarify the influences of the exposed chemicals on health in PTFE production we conducted a mass survey investigation in a PTFE production factory. As a result, in addition to the nephrotoxicity characterized by elevated ALP and NAG activities in urine, more interestingly, we have also found a reversible increase in cholinesterase (ChE) activity and enhanced urinary excretion of inorganic fluorides in workers engaged in PTFE production. We report here these findings and discuss their physiological significance. 18 refs., 4 tabs.« less
Fluoropolymer Films Deposited by Argon Ion-Beam Sputtering of Polytetrafluoroethylene
NASA Technical Reports Server (NTRS)
Golub, Morton A.; Banks, Bruce A.; Kliss, Mark (Technical Monitor)
1998-01-01
The FT-IR, XPS and UV spectra of fluoropolymer films (SPTFE-I) deposited by argon ion-beam sputtering of polytetrafluoroethylene (PTFE) were obtained and compared with prior corresponding spectra of fluoropolymer films (SPTFE-P) deposited by argon rf plasma sputtering of PTFE. Although the F/C ratios for SPTFE-I and -P (1.63 and 1.51) were similar, their structures were quite different in that there was a much higher concentration of CF2 groups in SPTFE-I than in SPTFE-P, ca. 61 and 33% of the total carbon contents, respectively. The FT-IR spectra reflect that difference, that for SPTFE-I showing a distinct doublet at 1210 and 1150 per centimeter while that for SPTFE-P presents a broad, featureless band at ca. 1250 per centimeter. The absorbance of the 1210-per centimeter band in SPTFE-I was proportional to the thickness of the film, in the range of 50-400 nanometers. The SPTFE-I was more transparent in the UV than SPTFE-P at comparable thickness. The mechanism for SPTFE-I formation likely involves "chopping off" of oligomeric segments of PTFE as an accompaniment to "plasma" polymerization of TFE monomer or other fluorocarbon fragments generated in situ from PTFE on impact with energetic Ar ions. Data are presented for SPTFE-I deposits and the associated Ar(+) bombarded PTFE targets where a fresh target was used for each run or a single target was used for a sequence of runs.
Tian, Jiangnan; Olajuyin, Ayobami Matthew; Mu, Tingzhen; Yang, Maohua; Xing, Jianmin
2016-06-01
The electro-Fenton (EF) process treatment of 0.1-M (rhodamine B) RhB solution was studied with different graphite cathode materials, and graphite felt (GF) was selected as a promising material in further investigation. Then, the degradation performances of gas diffusion electrode (GDE) and graphite felt (GF) were compared, and GDE was confirmed to be more efficient in RhB removal. The operational parameters such as Fe(2+) dosage and current density were optimized, and comparison among different modified methods-polytetrafluoroethylene-carbon black (PTFE-CB), polytetrafluoroethylene-carbon nanotube (PTFE-CNT), electrodeposition-CB, and electrodeposition-CNT-showed 98.49 % RhB removal by PTFE-CB-modified cathode in 0.05 M Na2SO4 at a current density of 50 A/m(2) and an air flow rate of 1 L/min after 20 min. Meanwhile, after cathode modified by PTFE-CB, the mineralization efficiency and mineralization current efficiency performed absolutely better than the pristine one. Cyclic voltammograms, SEM images, contact angles, and BET surface area were carried out to demonstrate stronger current responses and higher hydrophilicity of GF after modified. The value of biochemical oxygen demand/chemical oxygen demand (BOD5/COD) increased from 0.049 to 0.331 after 90-min treatment, suggesting the solution was biodegradable, and the modified cathode was confirmed to be stable after ten circle runs. Finally, a proposed degradation pathway of RhB was put forward.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pumphrey, C.W.; Chesebro, J.H.; Dewanjee, M.K.
Indium-111-labeled autologous platelets, injected 48 hours after operation, were used to evaluate the thrombogenicity of prosthetic material and the effect of platelet inhibitor therapy in vivo. Dacron double-velour (Microvel) aortofemoral artery bifurcation grafts were placed in 16 patients and unilateral polytetrafluoroethylene femoropopliteal grafts were placed in 10 patients. Half the patients in each group received platelet inhibitors before operation (dipyridamole, 100 mg 4 times a day) and after operation (dipyridamole, 75 mg, and acetylsalicylic acid, 325 mg 3 times a day); the rest of the patients served as control subjects. Five-minute scintigrams of the graft region were taken with amore » gamma camera interfaced with a computer 48, 72, and 96 hours after injection of the labeled platelets. Platelet deposition was estimated from the radioactivities of the grafts and expressed as counts per 100 pixels per microcurie injected. Dipyridamole and aspirin therapy significantly reduced the number of platelets deposited on Dacron grafts and prevented platelet accumulation over 3 days. With the small amount of platelet deposition on polytetrafluoroethylene femoropopliteal artery grafts even in control patients, platelet inhibitor therapy had no demonstrable effect on platelet deposition on these grafts. It is concluded that (1) platelet deposition on vascular grafts in vivo can be quantitated by noninvasive methods, and (2) dipyridamole and aspirin therapy reduced platelet deposition on Dacron aortofemoral artery grafts.« less
NASA Technical Reports Server (NTRS)
Bruegge, Carol J.; Stiegman, Albert E.; Rainen, Richard A.; Springsteen, Arthur W.
1993-01-01
Spectralon, a commercially available diffuse reflectance material made from polytetrafluoroethylene (PTFE), is being evaluated for the multiangle imaging spectroradiometer (MISR), currently under development for the Earth Observing System. Results of a series of environmental exposure tests indicate that no degradation of the optical properties was apparent following proton bombardment, and stability through UV illumination was satisfactory, provided simple cleaning and handling procedures were implemented. A buildup of several thousand volts of static charge was found to develop while simulating a rare pass through an auroral storm.
NASA Astrophysics Data System (ADS)
Kumeeva, T. Yu.; Prorokova, N. P.
2018-02-01
The surface properties of ultradisperse polytetrafluoroethylene coatings on polyethylene terephthalate materials modified in a supercritical carbon dioxide medium with co-solvent additions (aliphatic alcohols) were analyzed. An atomic force microscopy study revealed the peculiarities of the morphology of the hydrophobic coatings formed in the presence of co-solvents. The contribution of the co-solvents to the formation of the surface layer with a low surface energy was evaluated from the surface energy components of the modified polyester material. The stability of the coatings against dry friction was analyzed.
Plastic efficiency of different implants used for repair of soft and bone tissue defects.
Iriyanov, Yu M; Chernov, V F; Radchenko, S A; Chernov, A V
2013-08-01
The results of clinical and experimental morphological studies of regenerates forming after replacement of large defects of the abdominal wall and tibia with implants from different materials (polytetrafluoroethylene, reperene, prolene, titanium, and titanium nickelide) are analyzed. Study of the regenerate histology and fibroarchitectonics has shown good prospects of mesh constructions from titanium nickelide for effective surgical repair of these defects. The use of this implant seems to be theoretically well-based and promising, particularly under conditions of suppurative infection and low individual reparative regenerative potential.
Can Diastat Grafts Meet the Challenges of Daily Punctures?
Chandran, Prem K G; Messer, Diane; Sidwell, Richard A; Stubbs, David H; Nish, Andrew D
1997-01-01
To determine whether Diastat grafts can meet the challenges of daily needle punctures required for home hemodialysis (HD), a retrospective analysis was performed on the experience with 47 grafts placed in 44 patients receiving HD three times a week. The control group consisted of 17 patients who received 17 stretch polytetrafluoroethylene (s-PTFE) grafts. Apart from their ability to better contain bleeding after needle withdrawal, in all measures of longevity the Diastat grafts were outperformed by the s-PTFE grafts. No more direct data exist to address the original challenge.
Expanded polytetrafluoroethylene graft fistula for chronic hemodialysis.
Tellis, V A; Kohlberg, W I; Bhat, D J; Driscoll, B; Veith, F J
1979-01-01
In a retrospective study of 66 PTFE arteriovenous fistulae and 71 BCH arteriovenous fistulae for dialysis access, PTFE had a higher patency rate than BCH at 12 months (62.4 versus 32.5%). PTFE was easier to work with and easier to handle in the face of infection. The lateral upper arm approach to placement of the PTFE graft is desirable in patients who have had multiple previous access procedures because this area is usually free from scarring, is distant from neurovascular structures, and provides a greater length of graft for needle punctures.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Na, Han Kyu, E-mail: hankyu1324@empas.com; Song, Ho-Young, E-mail: hysong@amc.seoul.kr; Kim, Jin Hyoung, E-mail: m1fenew@hanmail.net
2013-02-15
This study was designed to compare the migration rates of covered stents with eight, four, and zero barbs in urethra-mimicking bovine pericardium models. Three types of polytetrafluoroethylene-covered retrievable self-expandable prostatic stents, with eight, four, and zero barbs, were tested in bovine pericardium models, consisting of normal saline-filled acrylic containers with tubes at both ends and a replica of the human urethra. The barbs were 2 mm in length and projected 60 Degree-Sign toward the urinary bladder. The anti-migration force (AMF) and resistance force against stent removal (RFSR) were measured by an automatic push-pull gauge system at a fixed rate (2more » mm/s). Significant differences in AMF among the three stent types were detected (P < 0.001). Median AMF was far greater for eight-barbed than for four-barbed stents (11.96 vs. 7.55 N, P = 0.003). For stent removal, the difference between 4- and 8-barbed stents were not significant in median static (5.54 vs. 6.08 N, P = 0.15) or sliding (prostatic urethra, 5.32 vs. 5.59 N, P = 0.65; membranous urethra, 7.78 vs. 8.57 N, P = 0.364) RFSR. No perforations or scratched traces were observed during removal of these stents. The inclusion of eight barbs projecting 60 Degree-Sign toward the urinary bladder were not only effective against stent migration in this model but suggests that these stents may be suitable for the treatment of prostatic urethral strictures without severely irritating the tissue. However, whether these results translate into living urethral tissue is unclear, necessitating further studies.« less
Grillitsch, Sandra; Medgyesy, Nikolaus; Schwerte, Thorsten; Pelster, Bernd
2005-01-01
Several studies suggest that during early larval development of lower vertebrates convective blood flow is not essential to supply oxygen to the tissues, but information about the oxygenation status of larvae during the time of cutaneous respiration is still missing. If convective oxygen transport contributes to the oxygen supply to tissues, venous blood in the central circulatory system should be partly deoxygenated, and hyperoxia should increase the oxygen saturation of the hemoglobin. To analyze the changes in hemoglobin oxygen saturation induced by hyperoxic incubation, zebrafish larvae were incubated in a tiny chamber between polytetrafluoroethylene membranes (Teflon), so that the oxygen supply could be rapidly modified. Hemoglobin oxygen saturation was measured in vivo by combining video imaging techniques with a spectrophotometrical analysis of hemoglobin light absorption at specific wavelengths for maximal absorption of oxygenated and deoxygenated blood (413 nm and 431 nm, respectively) under normoxic conditions and after a 10 min period of hyperoxia (P(O(2))=100 kPa), assuming that at a P(O(2)) of 100 kPa the hemoglobin is fully saturated. The results demonstrated that red blood cell oxygenation of zebrafish larvae at 4 days post fertilization (d.p.f.), 5 d.p.f. and 12 d.p.f. could be increased by hyperoxia. The data suggest that at the time of yolk sac degradation (i.e. 4 d.p.f. and 5 d.p.f.), when the total surface area of the animal is reduced, bulk diffusion of oxygen may not be sufficient to prevent a partial deoxygenation of the hemoglobin. The decrease in hemoglobin oxygenation observed at 12 d.p.f. confirms earlier studies indicating that at 12-14 d.p.f., convective oxygen transport becomes necessary to ensure oxygen supply to the growing tissues.
An electrochemical sensor device for measuring blood ammonia at the point of care.
Brannelly, N T; Killard, A J
2017-05-15
The level of ammonia in blood is relevant in a number of medical conditions. While ammonia is a marker of dysfunction, elevated ammonia is itself a serious medical emergency and can lead to significant and permanent neurological impairment if not addressed quickly. Blood ammonia testing is typically performed in the central laboratory. While a number of point of care devices have been developed, these are based on classical enzymatic or colorimetric principles and have not been widely adopted. In this work, an electrochemical sensor device was developed for measuring blood ammonia. The device was based on the deposition of polyaniline nanoparticle films onto screen printed interdigitated electrodes using inkjet printing and their integration into a polymer microfabricated device with a polytetrafluoroethylene membrane. The device required a 52µL serum sample and measured the change in impedance of the sensor with respect to air at 1kHz, 5mV rms. The device was capable of the measurement of ammonia in serum across the physiologically relevant range of 25-200µM (r 2 =0.9984) and had a limit of detection of 12µM (n =3). The device showed no significant issues with common electrochemical interferences in blood. The device was also validated against a commercial spectrophotometric assay which resulted in excellent correlation (r =0.9699, p<0.0001) between both methods (n =3). When stored under desiccation, devices displayed minimal variation over time (0.64%) with respect to their impedance in air (n =12) and could be stored in desiccant for at least five months. Copyright © 2017 Elsevier B.V. All rights reserved.
Myers, John W; Ghanayem, Nancy S; Cao, Yumei; Simpson, Pippa; Trapp, Katie; Mitchell, Michael E; Tweddell, James S; Woods, Ronald K
2014-02-01
To evaluate outcomes of systemic to pulmonary artery shunts (SPS) in patients weighing less than 3 kg with regard to shunt type, shunt size, and surgical approach. Patients weighing less than 3 kg who underwent modified Blalock-Taussig or central shunts with polytetrafluoroethylene grafts at our institution from January 1, 2000, to May 31, 2011, were reviewed. Patients who had undergone other major concomitant procedures were excluded from the analysis. Primary outcomes included mortality (discharge mortality and mortality before next planned palliative procedure or definitive repair), cardiac arrest and/or extracorporeal membrane oxygenation (ECMO), and shunt reintervention. In this cohort of 80 patients, discharge survival was 96% (77/80). Postoperative cardiac arrest or ECMO occurred in 6/80 (7.5%), and shunt reintervention was required in 14/80 (17%). On univariate analysis, shunt reintervention was more common in patients with 3-mm shunts (11/30, 37%) compared with 3.5-mm (2/36, 6%) or 4-mm shunts (1/14, 7%) (P < .003). There were no statistically significant associations between shunt type, shunt size, or surgical approach and cardiac arrest/ECMO or mortality. Multiple logistic regression demonstrated that a shunt size of 3 mm (P = .019) and extracardiac anomaly (P = .047) were associated with shunt reintervention, whereas no variable was associated with cardiac arrest/ECMO or mortality. In this high-risk group of neonates weighing less than 3 kg at the time of SPS, survival to discharge and the next planned surgical procedure was high. Outcomes were good with the 3.5- and 4-mm shunts; however, shunt reintervention was common with 3-mm shunts. Copyright © 2014 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.
Decellularized Diaphragmatic Muscle Drives a Constructive Angiogenic Response In Vivo.
Alvarèz Fallas, Mario Enrique; Piccoli, Martina; Franzin, Chiara; Sgrò, Alberto; Dedja, Arben; Urbani, Luca; Bertin, Enrica; Trevisan, Caterina; Gamba, Piergiorgio; Burns, Alan J; De Coppi, Paolo; Pozzobon, Michela
2018-04-28
Skeletal muscle tissue engineering (TE) aims to efficiently repair large congenital and acquired defects. Biological acellular scaffolds are considered a good tool for TE, as decellularization allows structural preservation of tissue extracellular matrix (ECM) and conservation of its unique cytokine reservoir and the ability to support angiogenesis, cell viability, and proliferation. This represents a major advantage compared to synthetic scaffolds, which can acquire these features only after modification and show limited biocompatibility. In this work, we describe the ability of a skeletal muscle acellular scaffold to promote vascularization both ex vivo and in vivo. Specifically, chicken chorioallantoic membrane assay and protein array confirmed the presence of pro-angiogenic molecules in the decellularized tissue such as HGF, VEGF, and SDF-1α. The acellular muscle was implanted in BL6/J mice both subcutaneously and ortotopically. In the first condition, the ECM-derived scaffold appeared vascularized 7 days post-implantation. When the decellularized diaphragm was ortotopically applied, newly formed blood vessels containing CD31⁺, αSMA⁺, and vWF⁺ cells were visible inside the scaffold. Systemic injection of Evans Blue proved function and perfusion of the new vessels, underlying a tissue-regenerative activation. On the contrary, the implantation of a synthetic matrix made of polytetrafluoroethylene used as control was only surrounded by vWF⁺ cells, with no cell migration inside the scaffold and clear foreign body reaction (giant cells were visible). The molecular profile and the analysis of macrophages confirmed the tendency of the synthetic scaffold to enhance inflammation instead of regeneration. In conclusion, we identified the angiogenic potential of a skeletal muscle-derived acellular scaffold and the pro-regenerative environment activated in vivo, showing clear evidence that the decellularized diaphragm is a suitable candidate for skeletal muscle tissue engineering and regeneration.
Use of radiation in biomaterials science
NASA Astrophysics Data System (ADS)
Benson, Roberto S.
2002-05-01
Radiation is widely used in the biomaterials science for surface modification, sterilization and to improve bulk properties. Radiation is also used to design of biochips, and in situ photopolymerizable of bioadhesives. The energy sources most commonly used in the irradiation of biomaterials are high-energy electrons, gamma radiation, ultraviolet (UV) and visible light. Surface modification involves placement of selective chemical moieties on the surface of a material by chemical reactions to improve biointeraction for cell adhesion and proliferation, hemocompatibility and water absorption. The exposure of a polymer to radiation, especially ionizing radiation, can lead to chain scission or crosslinking with changes in bulk and surface properties. Sterilization by irradiation is designed to inactivate most pathogens from the surface of biomedical devices. An overview of the use of gamma and UV radiation to improve surface tissue compatibility, bulk properties and surface properties for wear resistance, formation of hydrogels and curing dental sealants and bone adhesives is presented. Gamma and vacuum ultraviolet (VUV) irradiated ultrahigh molecular weight polyethylene (UHMWPE) exhibit improvement in surface modulus and hardness. The surface modulus and hardness of UHMWPE showed a dependence on type of radiation, dosage and processing. VUV surface modified e-PTFE vascular grafts exhibit increases in hydrophilicity and improvement towards adhesion of fibrin glue.
Using optical coherence tomography to evaluate glaucoma implant healing response in rabbit eyes
NASA Astrophysics Data System (ADS)
Gossage, Kirk W.; Tkaczyk, Tomasz S.; Barton, Jennifer K.
2002-06-01
Glaucoma is a set of diseases that cause optic nerve damage and visual field loss. The most important risk factor for the development of glaucoma is elevated intraocular pressure. One approach used to alleviate the pressure increase is to surgically install glaucoma implants. Two standard Ahmed and ten experimental ePTFE implants were evaluated in this study in rabbit eyes. The implants were imaged with optical coherence tomography (OCT) at 0, 7, 15, 30, and 90 days after implantation. Histology was collected at days 7, 15, 30, and 90 and compared to the OCT images. Preliminary analysis of images indicates that OCT can visualize the development of fibrous encapsulation of the implant, tissue erosion, fibrin accumulation in the implant tube, and tube position in the anterior chamber. A new OCT handheld probe was developed to facilitate in vivo imaging in rabbit eye studies. The OCT probe consists of a mechanical scaffold designed to allow the imaging fiber to be held in a fixed position with respect to the rabbit eye, with minimal anesthesia. A piezo electric lateral scanning device allows the imaging fiber to be scanned across the tissue so that 2D images may be acquired.
Smooth muscle cells improve endothelial cell retention on polytetrafluoroethylene grafts in vivo.
Yu, Hong; Dai, Wangde; Yang, Zhe; Kirkman, Paul; Weaver, Fred A; Eton, Darwin; Rowe, Vincent L
2003-09-01
We investigated the influence of smooth muscle cells (SMC) on endothelial cell (EC) retention on polytetrafluoroethylene (PTFE) grafts and the effect of SMC seeding on intimal hyperplasia in vivo in a rabbit model. Fibronectin-coated PTFE grafts (4 mm diameter) were seeded with either EC alone, SMC alone, or SMC followed 24 hours later by EC. The grafts were connected to an extracorporal aortic shunt for 1 hour or were individually implanted for 1, 30, and 100 days into the infrarenal aorta as an end-to-side bypass graft. The number of retained cells was compared at 1 hour and at 1 day after implantation. Neointimal thickness was measured 30 and 100 days after implantation. After 1-hour exposure to blood flow, EC retention rate was greater (P <.005) if seeded on top of SMC (98% +/- 2%; n = 8) versus being seeded alone (65 +/- 11%; n = 8). SMC retention rate was 95 +/- 5% (n = 8) when seeded alone. Similar cell retention was obtained 1 day after implantation. After 30-day implantation the neointima was thicker in grafts seeded with EC and SMC (282 +/- 136 microm; n = 3) than with EC only (52 +/- 45 microm; n = 3; P <.001). However, the neointimal thickness for dual-cell-seeded grafts (126 +/- 60 microm; n = 3) was not significantly different (P =.09) from EC-seeded grafts (79 +/- 48 microm; n = 3) after 100-day implantation. EC retention on PTFE grafts in vivo is improved if seeded over a layer of SMC. Further studies are needed to determine whether overlying EC modulate proliferation of underlying SMC.
Polytetrafluoroethylene Toxicosis in Recently Hatched Chickens (Gallus domesticus)
Shuster, Katherine A; Brock, Kristie L; Dysko, Robert C; DiRita, Victor J; Bergin, Ingrid L
2012-01-01
Two groups of chickens (Gallus domesticus; White Leghorn; age, 4 d and 2 wk) housed in a university research vivarium were found dead or moribund without prior signs of illness. The overall mortality rates were 92.3% (60 of 65 birds) for the 4-d-old birds and 80% (8 of 10) for the 2-wk-old birds. All chicks were housed in brooders with heat lamps in a temperature- and humidity-controlled room. Primary gross findings were mild to moderate dehydration and hepatic lipidosis. The most consistent histologic findings were pulmonary hemorrhage and edema in all 7 of the 4-d-old birds evaluated and in all 4 of the 2-wk-old birds assessed. In addition, 1 of the 4-d-old birds had multifocal centrilobular hepatic necrosis. These findings suggested an inhaled toxicant and hypoxia, respectively. Inspection of the animal room revealed that approximately 50% of the heat lamp bulbs in the brooder cage were coated with polytetrafluoroethylene (PTFE). Two published case reports detail similar experiences in birds exposed to PTFE-coated heat-lamp bulbs. Birds are highly sensitive to inhaled toxicants owing to the high efficiency of their respiratory systems, and PTFE toxicosis is known to cause pulmonary edema and hemorrhage in pet birds after exposure to overheated nonstick cookware. In the present case, the bulbs were replaced, and no similar problems subsequently have been noted. This case illustrates the sensitivity of avian species to respiratory toxicants and serves as a reminder that toxicosis can be encountered even in the controlled environment of a laboratory vivarium. PMID:22330651
Tribological interaction between polytetrafluoroethylene and silicon oxide surfaces
DOE Office of Scientific and Technical Information (OSTI.GOV)
Uçar, A.; Çopuroğlu, M.; Suzer, S., E-mail: suzer@fen.bilkent.edu.tr
2014-10-28
We investigated the tribological interaction between polytetrafluoroethylene (PTFE) and silicon oxide surfaces. A simple rig was designed to bring about a friction between the surfaces via sliding a piece of PTFE on a thermally oxidized silicon wafer specimen. A very mild inclination (∼0.5°) along the sliding motion was also employed in order to monitor the tribological interaction in a gradual manner as a function of increasing contact force. Additionally, some patterns were sketched on the silicon oxide surface using the PTFE tip to investigate changes produced in the hydrophobicity of the surface, where the approximate water contact angle was 45°more » before the transfer. The nature of the transferred materials was characterized by X-ray photoelectron spectroscopy (XPS) and scanning electron microscopy (SEM). XPS results revealed that PTFE was faithfully transferred onto the silicon oxide surface upon even at the slightest contact and SEM images demonstrated that stable morphological changes could be imparted onto the surface. The minimum apparent contact pressure to realize the PTFE transfer is estimated as 5 kPa, much lower than reported previously. Stability of the patterns imparted towards many chemical washing processes lead us to postulate that the interaction is most likely to be chemical. Contact angle measurements, which were carried out to characterize and monitor the hydrophobicity of the silicon oxide surface, showed that upon PTFE transfer the hydrophobicity of the SiO{sub 2} surface could be significantly enhanced, which might also depend upon the pattern sketched onto the surface. Contact angle values above 100° were obtained.« less
Validation of an automated fluorescein method for determining bromide in water
Fishman, M. J.; Schroder, L.J.; Friedman, L.C.
1985-01-01
Surface, atmospheric precipitation and deionized water samples were spiked with ??g l-1 concentrations of bromide, and the solutions stored in polyethylene and polytetrafluoroethylene bottles. Bromide was determined periodically for 30 days. Automated fluorescein and ion chromatography methods were used to determine bromide in these prepared samples. Analysis of the data by the paired t-test indicates that the two methods are not significantly different at a probability of 95% for samples containing from 0.015 to 0.5 mg l-1 of bromide. The correlation coefficient for the same sets of paired data is 0.9987. Recovery data, except for the surface water samples to which 0.005 mg l-1 of bromide was added, range from 89 to 112%. There appears to be no loss of bromide from solution in either type of container.Surface, atmospheric precipitation and deionized water samples were spiked with mu g l** minus **1 concentrations of bromide, and the solutions stored in polyethylene and polytetrafluoroethylene bottles. Bromide was determined periodically for 30 days. Automated fluorescein and ion chromatography methods were used to determine bromide in these prepared samples. Analysis of the data by the paired t-test indicates that the two methods are not significantly different at a probability of 95% for samples containing from 0. 015 to 0. 5 mg l** minus **1 of bromide. The correlation coefficient for the same sets of paired data is 0. 9987. Recovery data, except for the surface water samples to which 0. 005 mg l** minus **1 of bromide was added, range from 89 to 112%. Refs.
Role of anti-adhesive barriers following rotator cuff repair surgery: an experimental study.
Kalem, Mahmut; Şahin, Ercan; Songür, Murat; Zehir, Sinan; Armangil, Mehmet; Demirtaş, Mehmet A
2016-01-01
This experimental study investigates the effectiveness of expanded polytetrafluoroethylene (Dualmesh®, Gore Medical, Flagstaff, AZ, USA), sodium hyaluronate-carboxymethyl cellulose (Seprafilm®, Genzyme, Cambridge, MA, USA), and polysiloxane (silicone) as anti-adhesive barriers for inhibition of fibrosis in the subacromial area following rotator cuff repair. Rabbit rotator cuff tenotomy and repair was conducted on 24 rabbits in 4 groups: control (Group A), Dualmesh® (Group B), Seprafilm® (Group C), and silicone (Group D). Anti-adhesive barrier materials were sutured over the repaired rotator cuff. Macroscopic and histological evaluations were made at the end of the sixth postoperative week. Macroscopic evaluation revealed that minimal adhesion occurred in the control and silicone groups, while the Seprafilm® and Dualmesh® groups showed evidence of fibrosis. Microscopic evaluation revealed diffuse fibrosis and collagen accumulation in the Dualmesh® and Seprafilm® groups, whereas minimal collagen deposition and inflammatory cell reaction was found among the silicone and control groups. Significant differences were found between the silicone and Dualmesh® (p=0.001) and silicone and Seprafilm® groups (p=0.002), as well as between the control and Dualmesh® (p=0.002) and control and Seprafilm® groups (p=0.002). Expanded polytetrafluoroethylene (ePTFE/Dualmesh®) and sodium hyaluronate carboxymethyl cellulose (SH-CMC/Seprafilm®) did not prevent or attenuate postoperative subacromial fibrosis following cuff tear repair. Nor did silicone prevent or attenuate fibrosis. More detailed research is needed for development of an effective anti-adhesive barrier for use after rotator cuff tear surgery.
Paloma, V; Lasso, J M; Bazán, A; Serra, J M
1999-09-01
We have done an experimental study in lambs in which we investigated the influence of flow rate on free microvascular flaps using polytetrafluoroethylene (PTFE) vascular grafts. We set up five surgical groups in which blood flow was progressively increased through the PTFE vascular graft. In group I (venous autograft) we observed just one vascular thrombosis which was located at the site of the anastomosis. In group II (PTFE 3 x 10 mm) all the microvascular flaps became necrosed after the third postoperative day. In group III (PTFE 3 x 10 mm) necrosis also developed in all cases, but the anastomoses remained permeable no longer than eight days. In group IV (3 x 15 mm) the permeability in the microvascular free flaps was about 40% after 21 days, and in group V (3 x 10 mm) it reached 70%. To match graft flow rates with flap survival we did a regression analysis of flow rates for groups II, III, and V and the corresponding survival periods for the flaps. There was a clear and highly significant relationship (r = 0.717, p = 0.0001). In conclusion, it is necessary to maintain blood flow through the prosthesis at a rate higher than the thrombogenic threshold. When the flow rate in the vessels through the PTFE grafts was higher, the viability of the flaps was better. The ideal surgical technique should always be based on an arteriovenous fistula distal to the PTFE vascular graft. It is necessary to maintain blood flow through a prosthesis at a rate higher than the thrombogenic threshold.
NASA Astrophysics Data System (ADS)
Zhu, Jianxiong; Chen, Cong; Guo, Xiaoyu
2018-04-01
We report a suspended polytetrafluoroethylene (PTFE) nanostructure electret film in dual variable cavities for a self-powered micro-shock sensing application. The prototype contained series variable air cavities, a suspended nanostructure PTFE electret film and independent electrode films. The charges on the suspended nanostructure PTFE electret film provided the electrostatic field around the electret film in the series variable air cavities. When the reported device was driven by a micro-shock pressure, the inducted electrostatic charges on both the top and bottom electrodes would vary as the micro-shock pressing or releasing. Experimental results showed that the maximum of a short-circuit current density (J sc ) and an open-circuit voltage (V oc ) reached 3 ± 0.1 nA cm‑2 and 3.6 ± 0.1 V, respectively. It was found that the parameter J sc was more advantageous in identifying stronger shocks (parameter acceleration a bigger than 0.1 m s‑2), whereas the parameter V oc was more sensitive for weaker shocks, such as acceleration a smaller than 0.1 m s‑2. Moreover, finger continuous micro-shock pressure taps application was used to demonstrate the mechanical energy conversion performance with 4.5 ± 0.2 V open-circuit voltages. The research on the nanostructure electret PTFE film in series dual variable air cavities not only gave us a fresh idea about the principle and design of the shocking sensor, but also provided an easy fabrication and a low cost shocking sensor for the Internet of Things (IoT) systems.
Selective protection of poly(tetra-fluoroethylene) from effects of chemical etching
Martinez, Robert J.; Rye, Robert R.
1991-01-01
A photolithographic method for treating an article formed of polymeric material comprises subjecting portions of a surface of the polymeric article to ionizing radiation; and then subjecting the surface to chemical etching. The ionizing radiation treatment according to the present invention minimizes the effect of the subseuent chemical etching treatment. Thus, selective protection from the effects of chemical etching can be easily provided. The present invention has particular applicability to articles formed of fluorocarbons, such as PTFE. The ionizing radiation employed in the method may comprise Mg(k.alpha.) X-rays or lower-energy electrons.
Synthesis of metal and semiconductor nanoparticles in a flow of immiscible liquids
DOE Office of Scientific and Technical Information (OSTI.GOV)
Matyushkin, L. B., E-mail: leva.matyushkin@gmail.com; Ryzhov, O. A.; Aleksandrova, O. A.
Nanoparticles of silver and cadmium selenide are obtained by the method of synthesis in a flow of immiscible liquids (water/toluene, water/dodecane); these nanoparticles manifest, respectively, the effects of plasmon resonance and the spatial confinement of charge carriers. The reactor used is a polytetrafluoroethylene capillary with temperature-controlled sections for particle nucleation and growth with the supply of precursors using micropumps. The diameters of the particles are determined from absorbance spectra and are found to be 40 nm for Ag nanoparticles and 1–2 nm for CdSe nanoparticles (depending on the growth duration).
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang, Yang; Liu, Xiao Wei; Zhang, Hai Feng, E-mail: wy3121685@163.com
In this work, we present a method of fabricating super-hydrophobic surface on aluminum alloy substrate. The etching of aluminum surfaces has been performed using Beck's dislocation etchant for different time to create micrometer-sized irregular steps. An optimised etching time of 50 s is found to be essential before polytetrafluoroethylene (PTFE) coating, to obtain a highest water contact angle of 165±2° with a lowest contact angle hysteresis as low as 5±2°. The presence of patterned microstructure as revealed by scanning electron microscopy (SEM) together with the low surface energy ultrathin RF-sputtered PTFE films renders the aluminum alloy surfaces highly super-hydrophobic.
High contact angle hysteresis of superhydrophobic surfaces: Hydrophobic defects
NASA Astrophysics Data System (ADS)
Chang, Feng-Ming; Hong, Siang-Jie; Sheng, Yu-Jane; Tsao, Heng-Kwong
2009-08-01
A typical superhydrophobic surface is essentially nonadhesive and exhibits very low water contact angle (CA) hysteresis, so-called Lotus effect. However, leaves of some plants such as scallion and garlic with an advancing angle exceeding 150° show very serious CA hysteresis. Although surface roughness and epicuticular wax can explain the very high advancing CA, our analysis indicates that the unusual hydrophobic defect, diallyl disulfide, is the key element responsible for contact line pinning on allium leaves. After smearing diallyl disulfide on an extended polytetrafluoroethylene (PTFE) film, which is originally absent of CA hysteresis, the surface remains superhydrophobic but becomes highly adhesive.
NASA Technical Reports Server (NTRS)
Choi, Michael K.
2016-01-01
An innovative design of using microporous PTFE thin sheets as a solar diffuser for MLI blankets or mechanical structure has been developed. It minimizes sunlight or stray-light glint to cameras when it is incident on these components in space. A microporous black PTFE thin sheet solar diffuser has been qualified for flight at NASA GSFC and installed to the TAGSAM arm MLI, OCAMS PolyCam sunshade MLI and SamCam motor riser MLI in the NASA OSIRIS-REx mission to meet the SamCam camera BRDF requirement.
Pham, Tran N; Day, Caroline J; Edwards, Andrew J; Wood, Helen R; Lynch, Ian R; Watson, Simon A; Bretonnet, Anne-Sophie Z; Vogt, Frederick G
2011-01-25
We report a novel use of solid-state ¹⁹F nuclear magnetic resonance to detect and quantify polytetrafluoroethylene contamination from laboratory equipment, which due to low quantity (up to 1% w/w) and insolubility remained undetected by standard analytical techniques. Solid-state ¹⁹F NMR is shown to be highly sensitive to such fluoropolymers (detection limit 0.02% w/w), and is demonstrated as a useful analytical tool for structure elucidation of unknown solid materials. Copyright © 2010 Elsevier B.V. All rights reserved.
Surface diagnostics for scale analysis.
Dunn, S; Impey, S; Kimpton, C; Parsons, S A; Doyle, J; Jefferson, B
2004-01-01
Stainless steel, polymethylmethacrylate and polytetrafluoroethylene coupons were analysed for surface topographical and adhesion force characteristics using tapping mode atomic force microscopy and force-distance microscopy techniques. The two polymer materials were surface modified by polishing with silicon carbide papers of known grade. The struvite scaling rate was determined for each coupon and related to the data gained from the surface analysis. The scaling rate correlated well with adhesion force measurements indicating that lower energy materials scale at a lower rate. The techniques outlined in the paper provide a method for the rapid screening of materials in potential scaling applications.
Premeasured Chordal Loops for Mitral Valve Repair.
Gillinov, Marc; Quinn, Reed; Kerendi, Faraz; Gaudiani, Vince; Shemin, Richard; Barnhart, Glenn; Raines, Edward; Gerdisch, Marc W; Banbury, Michael
2016-09-01
Premeasured expanded polytetrafluoroethylene chordal loops with integrated sutures for attachment to the papillary muscle and leaflet edges facilitate correction of mitral valve prolapse. Configured as a group of 3 loops (length range 12 to 24 mm), the loops are attached to a pledget that is passed through the papillary muscle and tied. Each of the loops has 2 sutures with attached needles; these needles are passed through the free edge of the leaflet and then the sutures are tied to each other, securing the chordal loop to the leaflet. Copyright © 2016 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.
Expanded polytetrafluoroethylene graft fistula for chronic hemodialysis.
Tellis, V A; Kohlberg, W I; Bhat, D J; Driscoll, B; Veith, F J
1979-01-01
In a retrospective study of 66 PTFE arteriovenous fistulae and 71 BCH arteriovenous fistulae for dialysis access, PTFE had a higher patency rate than BCH at 12 months (62.4 versus 32.5%). PTFE was easier to work with and easier to handle in the face of infection. The lateral upper arm approach to placement of the PTFE graft is desirable in patients who have had multiple previous access procedures because this area is usually free from scarring, is distant from neurovascular structures, and provides a greater length of graft for needle punctures. Images Fig. 3. PMID:758853
NASA Astrophysics Data System (ADS)
Choi, Michael K.
2016-09-01
An innovative design of using microporous PTFE thin sheets as a solar diffuser for MLI blankets or mechanical structure has been developed. It minimizes sunlight or stray-light glint to cameras when it is incident on these components in space. A microporous black PTFE thin sheet solar diffuser has been qualified for flight at NASA GSFC and installed to the TAGSAM arm MLI, OCAMS PolyCam sunshade MLI and SamCam motor riser MLI in the NASA OSIRIS-REx mission to meet the SamCam camera BRDF requirement.
Preparation and properties of polytetrafluoroethylene impregnated with rhenium oxides
NASA Technical Reports Server (NTRS)
Leibecki, H. F.; Easter, R. W.
1973-01-01
The results of tests carried out to determine the properties of polytetrafluorethylene (PTFE) impregnated with rhenium oxides are presented. The tests included measurement of physical properties of the impregnated material and investigation of the effects of preparation process variables. Based on the latter tests a mechanism to describe the permeation process is postulated which identifies the rate controlling step to be diffusion of ReF6 molecules into the solid during the initial ReF6 soak. Physical property tests indicated that the electronic conductance is increased by many orders of magnitude while the desirable properties of the PTFE remain virtually unchanged.
Humidity-Induced Charge Leakage and Field Attenuation in Electric Field Microsensors
Zhang, Haiyan; Fang, Dongming; Yang, Pengfei; Peng, Chunrong; Wen, Xiaolong; Xia, Shanhong
2012-01-01
The steady-state zero output of static electric field measuring systems often fluctuates, which is caused mainly by the finite leakage resistance of the water film on the surface of the electric field microsensor package. The water adsorption has been calculated using the Boltzmann distribution equation at various relative humidities for borosilicate glass and polytetrafluoroethylene surfaces. At various humidities, water film thickness has been calculated, and the induced charge leakage and field attenuation have been theoretically investigated. Experiments have been performed with microsensors to verify the theoretical predictions and the results are in good agreement. PMID:22666077
DOE Office of Scientific and Technical Information (OSTI.GOV)
Blue, Robert C., E-mail: Robert.c.blue@gmail.com; Lo, Grace C.; Kim, Edward
PurposeA complication of transjugular intrahepatic portosystemic shunts (TIPS) placement is refractory portosystemic encephalopathy (PSE) often requiring TIPS reduction. We report the results of a “sheath control technique” utilizing constraining sheaths during deployment of polytetrafluoroethylene (PTFE)-covered balloon-expandable stents, minimizing stent migration, and providing additional procedural control.MethodsTIPS reduction was performed in 10 consecutive patients for PSE using Atrium iCast covered stents (Atrium Maquet Getinge Group, Germany). Within the indwelling TIPS stent, a 9 mm × 59 mm iCast stent was deployed with 2 cm exposed from the sheath’s distal end and the majority of the stent within the sheath to create the distal hourglass shape. During balloonmore » retraction, the stent was buttressed by the sheath. The proximal portion of the stent was angioplastied to complete the hourglass configuration, and the central portion of the stent was dilated to 5 mm. Demographics, pre- and post-procedure laboratory values, and outcomes were recorded.ResultsTen patients underwent TIPS reduction with 100 % technical success. There was no stent migration during stent deployment. All patients experienced initial improvement of encephalopathy. One patient ultimately required complete TIPS occlusion for refractory PSE, and another developed TIPS occlusion 36 days post-procedure. There was no significant trend toward change in patients’ MELD scores immediately post-procedure or at 30 days (p = 0.46, p = 0.47, respectively).ConclusionTIPS reduction using Atrium iCast PTFE balloon-expandable stents using the “sheath control technique” is safe and effective, and minimizes the risk of stent migration.« less
Yu, Hong; Dai, Wangde; Yang, Zhe; Romaguera, Rita L; Kirkman, Paul; Rowe, Vincent L
2005-01-01
The objective of this study was to examine the effect of tissue plasminogen activator (tPA) and endothelial nitric oxide synthase (eNOS) on thrombosis and neointimal hyperplasia on a polytetrafluoroethylene (PTFE) graft seeded with smooth muscle cells (SMCs). SMCs retrovirally transduced with tPA and eNOS genes were seeded on PTFE grafts and then implanted into the infrarenal rabbit aorta. Thrombosis and neointimal hyperplasia on the grafts were examined after 30 and 100 days of implantation. At 30 days of implantation, thrombus was observed on the luminal surface of both unseeded and SMC seeded control grafts, whereas grafts seeded with SMCs secreting tPA were nearly free of thrombus. At 100 days, the neointima on grafts seeded with tPA transduced SMCs was significantly thicker (925 +/- 150 microm, n = 5) than neointima on the other grafts (range, 132 to 374 microm; P < .001). Neointima thickness on grafts seeded with eNOS transduced SMCs (154 +/- 27 microm) was similar to that of unseeded grafts (132 +/- 16 microm, P > .05); both were thinner than those on grafts seeded with SMCs transduced with only lacZ gene (287 +/- 35 microm). The ratio of seeded cells in the neointima was significantly higher on SMC/tPA grafts (46% +/- 8%) than SMC/NOS grafts (21% +/- 6%, P < .05), indicating tPA transduced cells proliferated more than eNOS transduced cells. Engineered tPA expression in seeded SMCs causes significantly more neointimal hyperplasia, despite the favorable inhibition of luminal thrombus. eNOS expression in the seeded cells inhibits neointimal hyperplasia.
Silicone-Polytetrafluoroethylene Composite Implants for Asian Rhinoplasty.
Zelken, Jonathan A; Hong, Joon Pio; Chang, Chun-Shin; Hsiao, Yen-Chang
2017-02-01
Silicone and Gore-Tex implants are mainstays of Asian rhinoplasty. Silicone implants are inexpensive and wieldy, but may elicit a foreign-body reaction and are prone to migration. Gore-Tex implants are more biocompatible and capable of ingrowth but expensive. Silicone-polytetrafluoroethylene (PTFE) composites have a silicone core and PTFE liner. Composite implants have been marketed for several years, but are not yet established alternatives for rhinoplasty because of a lack of relevant reports. From February 2012 to June 2015, 177 Asian patients underwent primary (n = 63) or secondary (n = 114) rhinoplasty using an I-shaped composite implant. One hundred fifty-nine women and 18 men were 19 to 72 years old (mean, 34 years) at the time of surgery. Composite implants were 1.5 to 5 mm thick and 3.8 to 4.5 cm long. Autologous cartilage from the septum, concha, or both was used for tip refinement in every case. Glabellar augmentation was performed in 19 (10.7%) cases. Follow-up was 6.0 months (range, 1-36 months). There were 19 (10.7%) complications including malposition/deviation (4.5%), erythema (2.3%), and infection (1.1%). Four patients were unsatisfied, citing inadequate dorsal height correction. There was an 8.8% revision rate; 7 of 12 revisions were for malposition/deviation. We did not observe implant step-offs or extrusion. There were no differences in outcomes after primary or secondary rhinoplasty, although there was a trend toward higher infection rate after primary rhinoplasty (P = 0.06). I-shaped silicone-PTFE composite implants are feasible for both primary and secondary augmentation rhinoplasty in Asians. Early outcomes data suggest an overall complication rate that is comparable to PTFE alone.
Modified Ross procedure using a conduit with a synthetic valve.
Takabayashi, Shin; Kado, Hideaki; Shiokawa, Yuichi; Fukae, Kouji; Nakano, Toshihide
2004-12-01
In the Ross procedure, a homograft conduit is commonly used in place of an autotransplanted pulmonary valve. Homograft availability may be a problem and has resulted in a search for alternatives. We performed a modified Ross procedure for right ventricular outflow tract reconstruction with a synthetic valved conduit as an alternative to homograft. Our early results of valvular and right ventricular function were evaluated in patients who used a conduit with a synthetic valve. Subjects consisted of 11 patients, who ranged in age from 5 to 22 years (12.0+/-4.9), and whose body weight ranged from 15.1 to 52.5 (34.3+/-14.4) kg. Indications for surgery were aortic stenosis (n=3), aortic stenosis and regurgitation (n=4), and aortic regurgitation (n=4). Right ventricular outflow tract reconstruction was performed using a hand-fashioned valved conduit prepared by sewing a 0.1 mm thick polytetrafluoroethylene sheet onto the luminal cavity of the 20-28 mm conduit. A conduit made with polytetrafluoroethylene was used in 8 patients, and a Dacron graft was used in 3 patients. There was no in-hospital or late mortality and angiocardiography at discharge revealed that all artificial valves remained active. The mean right atrial pressure and right ventricular end-diastolic pressure were not statistically different from preoperative values. The latest echocardiography (mean interval, 12.6 months) revealed that a mean pressure gradient across the synthetic valve was 11.4+/-11.1 mmHg and none of the patients had moderate or severe regurgitation. We demonstrated that a modified Ross procedure for right ventricular outflow tract reconstruction using a conduit with an appropriate synthetic valve is particularly effective in older children.
Glickman, Marc; Gheissari, Ali; Money, Samuel; Martin, John; Ballard, Jeffrey L
2002-03-01
An experimental polymeric sealant (CoSeal [Cohesion Technologies, Palo Alto, Calif]) provides equivalent anastomotic sealing to Gelfoam (Upjohn, Kalamazoo, Mich)/thrombin during surgical placement of prosthetic vascular grafts. Randomized controlled trial. Nine university-affiliated medical centers. One hundred forty-eight patients scheduled for implantation of polytetrafluoroethylene grafts, mainly for infrainguinal revascularization procedures or the creation of dialysis access shunts, who were treated randomly with either an experimental intervention (n = 74) or control (n = 74). Following polytetrafluoroethylene graft placement, anastomotic suture hole bleeding was treated intraoperatively in all control subjects with Gelfoam/thrombin. Subjects in the experimental group had the polymeric sealant applied directly to the suture lines without concomitant manual compression. Primary treatment success was defined as the proportion of subjects in each group that achieved complete anastomotic sealing within 10 minutes. The proportion of subjects that achieved immediate sealing and the time required to fully inhibit suture hole bleeding also were compared between treatment groups. Overall 10-minute sealing success was equivalent (86% vs 80%; P =.29) between experimental and control subjects, respectively. However, subjects treated with CoSeal achieved immediate anastomotic sealing at more than twice the rate of subjects treated with Gelfoam/thrombin (47% vs 20%; P<.001). Consequently, the median time needed to inhibit bleeding in control subjects was more than 10 times longer than for experimental subjects (16.5 seconds vs 189.0 seconds; P =.01). Strikingly similar findings for all comparisons were observed separately for subgroups of subjects having infrainguinal bypass grafting and for those undergoing placement of dialysis access shunts. The experimental sealant offers equivalent anastomotic sealing performance compared with Gelfoam/thrombin, but it provides this desired effect in a significantly more rapid time frame.
Viscosities of implantable biomaterials in vocal fold augmentation surgery.
Chan, R W; Titze, I R
1998-05-01
Vocal fold vibration depends critically on the viscoelasticity of vocal fold tissues. For instance, phonation threshold pressure, a measure of the "ease" of phonation, has been shown to be directly related to the viscosity of the vibrating mucosa. Various implantable biomaterials have been used in vocal fold augmentation surgery, with implantation sites sometimes close to or inside the mucosa. Yet their viscosities or other mechanical properties are seldom known. This study attempts to provide data on viscosities of commonly used phonosurgical biomaterials. Using a parallel-plate rotational rheometer, oscillatory shear experiments were performed on implantable polytetrafluoroethylene (Teflon or Polytef; Mentor Inc., Hingham, MA), collagen (Zyderm; Collagen Corp., Palo Alto, CA), glutaraldehyde crosslinked (GAX) collagen (Phonagel or Zyplast; Collagen Corp.), absorbable gelatin (Gelfoam; Upjohn Co., Kalamazoo, MI), and human abdominal subcutaneous fat. Samples of human vocal fold mucosal tissues were also tested. Under sinusoidal oscillatory shear at 10 Hz and at 37 degrees C, the dynamic viscosity was 116 Pascal-seconds (Pa-s) for polytetrafluoroethylene, 21 Pa-s for gelatin, 8-13 Pa-s for the two types of collagen, 3 Pa-s for fat, and 1 to 3 Pa-s for vocal fold mucosa. Results extrapolated to 100 Hz also show similar differences among the biomaterials, but all values are an order of magnitude lower because of the typical inverse frequency relation (shear thinning effect) for polymeric and biologic materials. The data suggest that the use of fat for vocal fold augmentation may be more conducive to the "ease" of phonation because of its relatively low viscosity, which is closest to physiologic levels. This implication is probably the most relevant in predicting initial outcome of the postoperative voice before there is any significant assimilation (e.g., resorption and fibrosis) of the implanted biomaterial.
Plasma-Functionalized Polytetrafluoroethylene Nanoparticles for Improved Wear in Lubricated Contact
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sharma, Vinay; Timmons, Richard; Erdemir, Ali
Plasma-functionalized polytetrafluoroethylene (PTFE) nanoparticles were employed to evaluate their utility in improving the lubrication property of a group III mineral oil with a significantly low amount of zinc dialkyl dithiophosphate (ZDDP). The particles were coated with two consecutive films; the initial coating contained silica to enhance amorphous glassy tribofilm formation, followed by a methacrylate film to protect the silica coating and enhance dispersibility in the oil. The functionalized nanoparticles were evaluated for their tribological performance using a high-frequency reciprocating rig, in a cylinder-on-flat configuration. The oil formulations containing ZDDP (350 ppm phosphorus level) and the functionalized nanoparticles resulted in dramaticmore » reductions in the friction coefficient and overall wear compared to the samples containing nonfunctionalized PTFE nanoparticles, ZDDP (350 ppm P), and samples devoid of nanoparticles but containing ZDDP with a 700 ppm P treat rate. XPS and XANES spectroscopy were employed to characterize the tribological films formed on the test samples. The samples with functionalized particles and ZDDP clearly exhibited tribofilms with Si- and F-doped polyphosphates of Zn coupled with the presence of ZnS at the metal-tribofilm interface. On the other hand, oils without the functionalized nanoparticles have oxides of Fe and to a lesser extent short-chain phosphates of Zn. The overall results suggest that the synergism between plasma-coated PTFE nanoparticles and ZDDP contributed to the development of protective tribofilms even at reduced amount of phosphorus in the oil. This new method of employing nanoparticles to deliver novel antifriction and antiwear chemistries at the tribological interfaces stands out as a promising approach to further reduce P levels in oils without compromising friction and wear performance.« less
NASA Astrophysics Data System (ADS)
Unal, H.; Mimaroglu, A.; Arda, T.
2006-09-01
Wear experiments have been carried out with a range of unfilled and filled engineering thermoplastic polymers sliding against a 15% glass fibre reinforced unsaturated polyester polymer under 20, 40 and 60 N loads and 0.5 m/s sliding speed. Pin materials used in this experimental investigation are polyamide 66 (PA 66), poly-ether-ether-ketone (PEEK) and aliphatic polyketone (APK), glass fibre reinforced polyamide 46 (PA 46 + 30% GFR), glass fibre reinforced polytetrafluoroethylene (PTFE + 17% GFR), glass fibre reinforced poly-ether-ether-ketone (PEEK + 20% GFR), glass fibre reinforced poly-phylene-sulfide (PPS + 30% GFR), polytetrafluoroethylene filled polyamide 66 (PA 66 + 10% PTFE) and bronze filled pofytetrafluoroethylene (PTFE + 25% bronze) engineering polymers. The disc material is a 15% glass fibre reinforced unsaturated polyester thermoset polymer produced by Bulk Moulding Compound (BMC). Sliding wear tests were carried out on a pin-on-disc apparatus under 0.5 m/s sliding speed and load values of 20, 40 and 60 N. The results showed that the highest specific wear rate is for PPS + 30% GFR with a value of 1 × 10 -11 m 2/N and the lowest wear rate is for PTFE + 17% GFR with a value of 9.41 × 10 -15 m 2/N. For the materials and test conditions of this investigation, apart from polyamide 66 and PA 46 + 30% GFR polymers, the coefficient of friction and specific wear rates are not significantly affected by the change in load value. For polyamide 66 and PA 46 + 30% GFR polymers the coefficient of friction and specific wear rates vary linearly with the variation in load values.
Jin, Qiaofeng; Kang, Shih-Tsung; Chang, Yuan-Chih; Zheng, Hairong; Yeh, Chih-Kuang
2016-09-01
Nanoscale gas bubbles residing on a macroscale hydrophobic surface have a surprising long lifetime (on the order of days) and can serve as cavitation nuclei for initiating inertial cavitation (IC). Whether interfacial nanobubbles (NBs) reside on the infinite surface of a hydrophobic nanoparticle (NP) and could serve as cavitation nuclei is unknown, but this would be very meaningful for the development of sonosensitive NPs. To address this problem, we investigated the IC activity of polytetrafluoroethylene (PTFE) NPs, which are regarded as benchmark superhydrophobic NPs due to their low surface energy caused by the presence of fluorocarbon. Both a passive cavitation detection system and terephthalic dosimetry was applied to quantify the intensity of IC. The IC intensities of the suspension with PTFE NPs were 10.30 and 48.41 times stronger than those of deionized water for peak negative pressures of 2 and 5MPa, respectively. However, the IC activities were nearly completely inhibited when the suspension was degassed or ethanol was used to suspend PTFE NPs, and they were recovered when suspended in saturated water, which may indicates the presence of interfacial NBs on PTFE NPs surfaces. Importantly, these PTFE NPs could sustainably initiate IC for excitation by a sequence of at least 6000 pulses, whereas lipid microbubbles were completely depleted after the application of no more than 50 pulses under the same conditions. The terephthalic dosimetry has shown that much higher hydroxyl yields were achieved when PTFE NPs were present as cavitation nuclei when using ultrasound parameters that otherwise did not produce significant amounts of free radicals. These results show that superhydrophobic NPs may be an outstanding candidate for use in IC-related applications. Copyright © 2016 Elsevier B.V. All rights reserved.
Effects of simulant mixed waste on EPDM and butyl rubber
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nigrey, P.J.; Dickens, T.G.
1997-11-01
The authors have developed a Chemical Compatibility Testing Program for the evaluation of plastic packaging components which may be used in transporting mixed waste forms. In this program, they have screened 10 plastic materials in four liquid mixed waste simulants. These plastics were butadiene-acrylonitrile copolymer (Nitrile) rubber, cross-linked polyethylene, epichlorohydrin rubber, ethylene-propylene (EPDM) rubber, fluorocarbons (Viton and Kel-F{trademark}), polytetrafluoro-ethylene (Teflon), high-density polyethylene, isobutylene-isoprene copolymer (Butyl) rubber, polypropylene, and styrene-butadiene (SBR) rubber. The selected simulant mixed wastes were (1) an aqueous alkaline mixture of sodium nitrate and sodium nitrite; (2) a chlorinated hydrocarbon mixture; (3) a simulant liquid scintillation fluid; andmore » (4) a mixture of ketones. The screening testing protocol involved exposing the respective materials to approximately 3 kGy of gamma radiation followed by 14-day exposures to the waste simulants at 60 C. The rubber materials or elastomers were tested using Vapor Transport Rate measurements while the liner materials were tested using specific gravity as a metric. The authors have developed a chemical compatibility program for the evaluation of plastic packaging components which may be incorporated in packaging for transporting mixed waste forms. From the data analyses performed to date, they have identified the thermoplastic, polychlorotrifluoroethylene, as having the greatest chemical compatibility after having been exposed to gamma radiation followed by exposure to the Hanford Tank simulant mixed waste. The most striking observation from this study was the poor performance of polytetrafluoroethylene under these conditions. In the evaluation of the two elastomeric materials they have concluded that while both materials exhibit remarkable resistance to these environmental conditions, EPDM has a greater resistance to this corrosive simulant mixed waste.« less
Miller, Kyle J; Cao, Wei; Ibrahim, Mohamed M; Levinson, Howard
2017-04-01
Hemostasis, the initial phase of wound healing, sets the stage for tissue repair. Microporous polysaccharide hemosphere powder (MPH) is an FDA-approved hemostatic agent that may impact the wound-healing process. This study examined the role of MPH in murine wild-type and diabetic (db/db) wound-healing models and a foreign body response scarring model. The powder was topically applied to excisional wounds in wild-type C57BL/6 mice and db/db mice. The effect of MPH on scarring was evaluated by applying it to the expanded polytetrafluoroethylene tube implantation model. In wild-type mice, topically applied MPH increased epithelial thickness. Levels of α-smooth muscle actin (α-SMA) were decreased in MPH-treated wild-type wounds, whereas Rho-associated protein kinase 2 (ROCK2) and transforming growth factor β levels were increased. In db/db mice, topical wound MPH application decreased epithelial thickness and delayed wound closure. The db/db wounds displayed an increased collagen index. The ROCK2 was increased in a similar manner to wild-type mice, whereas α-SMA and transforming growth factor β levels were decreased. The MPH-treated expanded polytetrafluoroethylene tube mice showed increased α-SMA levels and depressed ROCK2 levels. There were no changes in histologic parameters of the foreign body response. The results suggest that MPH does not adversely impact wound healing in wild-type mice, both topically and around implants, but prolongs time to closure and diminishes thickness in db/db wounds. The MPH application alters contractile proteins in all wound models. These changes could have downstream effects on the wound healing process, and further investigation into the use of MPH in altered or impaired states of wound healing is warranted.
Bioactive coating with low-fouling polymers for the development of biocompatible vascular implants
NASA Astrophysics Data System (ADS)
Thalla, Pradeep Kumar
The replacement of occluded blood vessels and endovascular aneurysm repair (EVAR) are performed with the use of synthetic vascular grafts and stent grafts, respectively. Both implants lead to frequent clinical complications that are different but due to a similar problem, namely the inadequate surface properties of the polymeric biomaterials used (generally polyethylene terephthalate (PET) or expanded polytetrafluoroethylene (ePTFE)). Therefore the general objective of this thesis was to create a versatile bioactive coating on vascular biomaterials that reduce material-induced thrombosis and promote desired cell interactions favorable to tissue healing around implants. The use of low-fouling backgrounds was decided in order to reduce platelet adhesion as well as the non-specific protein adsorption and thus increase the bioactivity of immobilized biomolecules. As part of the preliminary objective, a multi-arm polyethylene glycol (PEG) was chosen to create a versatile low-fouling surface, since the current coating methods are far from being versatile and rely on the availability of compatible functional groups on both PEG and the host surface. This PEG coating method was developed by taking advantage of novel primary amine-rich plasma polymerized coatings (LP). As demonstrated by quartz crystal microbalance with dissipation (QCM-D), fluorescence measurements and platelet adhesion assays, our PEG coatings exhibited low protein adsorption and almost no platelet adhesion after 15 min perfusion in whole blood. Although protein adsorption was not completely abrogated and short-term platelet adhesion assay was clearly insufficient to draw conclusions for long-term prevention of thrombosis in vivo, the low-fouling properties of this PEG coating were sufficient to be exploited for further coupling of bioactive molecules to create bioactive coatings. Therefore, as a part of the second objective, an innovative and versatile bioactive coating was developed on PEG and carboxymethylated dextran (CMD), using the combination of an adhesive peptide (KQAGDV/RGD) and epidermal growth factor (EGF). CMD was chosen as an alternative to PEG due to its better low-fouling properties and the presence of abundant carboxyl terminal groups. Although the QCM-D technique enabled us to optimize the combined immobilization of KQAGDV/RGD and EGF, cell adhesion assay results did not show improvement of vascular smooth muscle cell (VSMC) adhesion on peptide-modified PEG or CMD surfaces. Among the reasons explaining low cell adhesion on peptides grafted low-fouling surfaces is the difficulty of preventing protein adsorption/platelet adhesion without significantly reducing cell adhesion. Preliminary data in our laboratory indicated that CS could be an ideal substrate to find this compromise. For that reason, the final objective of this PhD consisted in evaluating the potential of chondroitin sulfate (CS) coating by comparing its properties with well-known low-fouling polymers such as PEG and CMD. It was shown that CS presents selective low-fouling properties, low-platelet adhesion and pro-endothelial cell (EC) adhesive properties As demonstrated by QCM-D and fluorescence measurements, CS was as effective as PEG in reducing fibrinogen adsorption, but it reduced adsorption of bovine serum albumin (BSA) and fetal bovine serum (FBS) to a lower extent than PEG and CMD surfaces. Whole blood perfusion assays indicated that all three surfaces drastically decreased platelet adhesion and activation to levels significantly lower than PET surfaces. However, while EC adhesion and growth were found to be very limited on PEG and CMD, cell attachment on CS was strong, with focal adhesion points and resistance to shear stress. CS coatings therefore form a low-thrombogenic background promoting the formation of a confluent endothelium layer, which may then act as an active anti-thrombogenic surface. CS coating can also be used to further graft biomolecules. Combination of LP, CS coating followed by GF immobilization shows great promise as a bioactive coating to optimize the biocompatibility and clinical outcome of vascular implants, in particular vascular grafts.
Improved Separators For Rechargeable Lithium Cells
NASA Technical Reports Server (NTRS)
Shen, David; Surampudi, Subbarao; Huang, Chen-Kuo; Halpert, Gerald
1994-01-01
Improved pairs of separators proposed for use in rechargeable lithium cells operating at ambient temperature. Block growth of lithium dendrites and help prevent short circuits. Each cell contains one separator made of microporous polypropylene placed next to anode, and one separator made of microporous polytetrafluoroethylene (PTFE) next to cathode. Separators increase cycle lives of secondary lithium cells. Cells to which concept applicable those of Li/TiS(2), Li/NbSe(3), Li/CoO(2), Li/MoS(2), Li/VO(x), and Li/MnO(2) chemical systems. Advantageous in spacecraft, military, communications, automotive, and other applications in which high energy density and rechargeability needed.
Preliminary Evaluation of Greases for Space Mechanisms Using a Vacuum Spiral Orbit Tribometer
NASA Technical Reports Server (NTRS)
Marchetti, Mario; Jones, William R., Jr.; Street, Kenneth W.; Pepper, Stephen V.; Jansen, Mark J.
2001-01-01
Most currently used greases for space applications are based on perfluoropolyalkylethers (PFPE) and multiply alkylated cyclopentane (MAC) oils. Evaluation of the greases includes outgassing properties, rheological behavior, and particularly the ability to create EHL films under conditions as close as possible to an actual application. A spiral orbit tribometer (SOT) has been developed to conduct accelerated tests under realistic conditions. The SOT was employed to evaluate two greases used in space mechanisms: a PFPE oil with polytetrafluoroethylene (PTFE) thickener, and a multiply alkylated cyclopentane oil with n-octadecylterephthalamate soap. The results from the greases are in agreement with results previously obtained with the base oils.
Improved conductivity of carbon-nano-fiber (CNF)/polytetrafluoroethylene (PTFE) composite
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chandra, Sarita; Kalra, G. S.; Pushkar, Vinay K.
2016-05-23
A series of CNF/PTFE composite loaded with different weight % of CNFs as 0.01, 0.02, 0.03, 0.05, 1, 2, 3, 4, 5 into PTFE is fabricated. In this work, the 5wt% heat-treated CNFs were used as filler in PTFE. Current-voltage (I-V) study of the samples confirmed the samples as conducting composite. In scanning electron microscope (SEM) study, the conducting CNFs channels were observed from upper surface to inside throughout the polymer matrix. A sintered composite of 5 wt% loading of CNFs showed an improved conductivity and SEM image exhibited a good binding of CNFs into PTFE.
Apparatus for inspecting piping
Zollingger, W. Thor; Appel, D. Keith; Park, Larry R.
1995-01-01
An inspection rabbit for inspecting piping systems having severe bends therein. The rabbit consists of a flexible, modular body containing a miniaturized eddy current inspection probe, a self-contained power supply for proper operation of the rabbit, an outer surface that allows ease of movement through piping systems and means for transmitting data generated by the inspection device. The body is preferably made of flexible polyvinyl chloride (PVC) tubing or, alternatively, silicone rubber with a shrink wrapping of polytetrafluoroethylene (TEFLON.RTM.). The body is formed to contain the power supply, preferably a plurality of batteries, and a spool of communication wire that connects to a data processing computer external to the piping system.
Mahfouz, Ayman; Naji, Meeran; Mok, Wing Yan; Taghi, Ali S; Win, Zarni
2015-09-01
A false-positive uptake of F18-fluorodeoxyglucose (FDG) on positron-emission tomography/computed tomography (PET/CT) can result in confusion and misinterpretation of scans. Such uptakes have been previously described after injection of polytetrafluoroethylene (Teflon) into the vocal folds. Similarly, vocal fold injection of silicone elastomer (Silastic) can result not only in a false-positive FDG uptake on PET/CT, but also in chronic inflammation. We report a case of increased FDG uptake in a vocal fold after Silastic injection that was misinterpreted as a malignancy in a 70-year-old woman who had metastatic carcinoma of the stomach.
Modified loop technique in three dogs with mitral regurgitation.
Aoki, Takuma; Fujii, Yoko; Sunahara, Hiroshi; Takano, Hiroshi; Wakao, Yoshito
2013-01-31
Mitral valvuloplasty (MVP) is used in dogs with refractory mitral regurgitation (MR); however, it is difficult to tie the artificial chord, i.e., the expanded polytetrafluoroethylene suture, at the planned height of the mitral valve, because of the slippery nature of the knot. The loop technique has resolved these difficulties in humans. Premanufactured loops (length, 8.0-15.0 mm with 1.0-mm increments) were used in the new modified loop technique. In the current study, cardiac murmurs disappeared, and the MR markedly improved or completely disappeared approximately 3 months after surgery in 3 dogs. Therefore, this new technique might be effective in dogs.
A study of Na(x)Pt3O4 as an O2 electrode bifunctional electrocatalyst
NASA Technical Reports Server (NTRS)
Fielder, William L.; Singer, Joseph
1991-01-01
The present study suggests that polytetrafluoroethylene (PTFE) bonded Na(X)Pt3O4 gas porous diffusion electrodes may be a viable candidate for bifunctional O2 reduction and evolution activity. The electrodes exhibited Tafel slopes of about 0.06 V/decade for both O2 reduction an evolution. For O2 reduction, the 0.06 slope doubled to 0.12 V/decade at larger current densities. Preliminary stability testing at 24 C suggest that the Na(x)Pt3O4 electrodes were relatively stable at reducing and oxidizing potentials typically encountered at the O2 electrodes in a regenerative fuel cell.
Adhesion and transfer of PTFE to metals studied by auger emission spectroscopy
NASA Technical Reports Server (NTRS)
Pepper, S. V.; Buckley, D. H.
1972-01-01
The adhesion and transfer of polytetrafluoroethylene (PTFE) to metals in ultrahigh vacuum has been studied using Auger emission spectroscopy. The transfer was effected both by compressive static contact and by sliding contact. The transfer observed after static contact was independent of the chemical constitution of the substrate. Electron induced desorption of the fluorine in the transferred PTFE showed that the fluorine had no chemical interaction with the metal substrate. The coefficient of friction on metals was independent of the chemical constitution of the substrate. However, sliding PTFE on soft metals such as aluminum, generated wear fragments that lodged in the PTFE and machined the substrate.
Adhesion and transfer of polytetrafluorethylene to metals studied by Auger emission spectroscopy
NASA Technical Reports Server (NTRS)
Pepper, S. V.; Buckley, D. H.
1972-01-01
The adhesion and transfer of polytetrafluoroethylene (PTFE) to metals in ultrahigh vacuum were studied. The transfer was effected both by compressive static contact and by sliding contact. The transfer observed after static contact was independent of the chemical constitution of the substrate. Electron-induced desorption of the fluorine in the transferred PTFE showed that the fluorine had no chemical interaction with the metal substrate. The coefficient of friction on metals was independent of the chemical constitution of the substrate. However, sliding PTFE on soft metals, such as aluminum, generated wear fragments that lodged in the PTFE and machined the substrate.
Exploiting pattern transformation to tune phononic band gaps in a two-dimensional granular crystal.
Göncü, F; Luding, S; Bertoldi, K
2012-06-01
The band structure of a two-dimensional granular crystal composed of silicone rubber and polytetrafluoroethylene (PTFE) cylinders is investigated numerically. This system was previously shown to undergo a pattern transformation with uniaxial compression by Göncü et al. [Soft Matter 7, 2321 (2011)]. The dispersion relations of the crystal are computed at different levels of deformation to demonstrate the tunability of the band structure, which is strongly affected by the pattern transformation that induces new band gaps. Replacement of PTFE particles with rubber ones reveals that the change of the band structure is essentially governed by pattern transformation rather than particles' mechanical properties.
Tsujikawa, Kenji; Saiki, Fujio; Yamamuro, Tadashi; Iwata, Yuko T; Abe, Ryoji; Ohashi, Hiroyuki; Kaigome, Rena; Yamane, Kyosuke; Kuwayama, Kenji; Kanamori, Tatsuyuki; Inoue, Hiroyuki
2016-09-01
We developed a novel immunoassay for herbal cannabis based on a new immunoassay principle that uses Ultra Quenchbody ("UQ-body"), a recombinant antibody Fab fragment fluorolabeled at the N-terminal regions. When the antigen binds to anti-Δ(9)-tetrahydrocannabinol (THC) UQ-body, the fluorescence intensity (FI) decreases. The analytical conditions of the immunoassay were optimized based on the FI reduction rate (FIRR). Following are the steps in the final analytical procedure: (1) 10mg of samples were extracted with 1ml of a 60:40 mixture of methanol and phosphate-buffered saline (PBS); (2) the extract was filtered through a centrifugal 0.2-μm polytetrafluoroethylene membrane filter; (3) the filtrate was diluted 100 times with extraction solvent; (4) 6-μl diluted solution was mixed with 19-μl PBS and 75-μl UQ-body solution; and (5) FIRR was measured under 275-mV excitation light. Herbal cannabis samples containing ≥4.0-mg/g THC gave FIRRs of ≥5.2%. FIRRs of negative samples (cigarette, tea, spice, and so-called "synthetic marijuana") were ≤3.1%. When setting the FIRR threshold to 5.0%, cannabis samples containing ≥4.0-mg/g THC were correctly judged as positive without being affected by false positives caused by the negative samples. This detection limit was lower than total THC level (10-200mg/g) in most herbal cannabis samples seized in Japan. In seven of the 10 cannabis samples, the results of the UQ-body test were comparable with those of the Duquenois-Levine test. Thus, the UQ-body-based immunoassay is presumed to be an effective and objective drug screening method for herbal cannabis; however, to show the true usefulness, it is necessary to test a number of real case samples in the field situation. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Anti-tumor therapy with macroencapsulated endostatin producer cells
2010-01-01
Background Theracyte is a polytetrafluoroethylene membrane macroencapsulation system designed to induce neovascularization at the tissue interface, protecting the cells from host's immune rejection, thereby circumventing the problem of limited half-life and variation in circulating levels. Endostatin is a potent inhibitor of angiogenesis and tumor growth. Continuous delivery of endostatin improves the efficacy and potency of the antitumoral therapy. The purpose of this study was to determine whether recombinant fibroblasts expressing endostatin encapsulated in Theracyte immunoisolation devices can be used for delivery of this therapeutic protein for treatment of mice bearing B16F10 melanoma and Ehrlich tumors. Results Mice were inoculated subcutaneously with melanoma (B16F10 cells) or Ehrlich tumor cells at the foot pads. Treatment began when tumor thickness had reached 0.5 mm, by subcutaneous implantation of 107 recombinant encapsulated or non-encapsulated endostatin producer cells. Similar melanoma growth inhibition was obtained for mice treated with encapsulated or non-encapsulated endostatin-expressing cells. The treatment of mice bearing melanoma tumor with encapsulated endostatin-expressing cells was decreased by 50.0%, whereas a decrease of 56.7% in tumor thickness was obtained for mice treated with non-encapsulated cells. Treatment of Ehrlich tumor-bearing mice with non-encapsulated endostatin-expressing cells reduced tumor thickness by 52.4%, whereas lower tumor growth inhibition was obtained for mice treated with encapsulated endostatin-expressing cells: 24.2%. Encapsulated endostatin-secreting fibroblasts failed to survive until the end of the treatment. However, endostatin release from the devices to the surrounding tissues was confirmed by immunostaining. Decrease in vascular structures, functional vessels and extension of the vascular area were observed in melanoma microenvironments. Conclusions This study indicates that immunoisolation devices containing endostatin-expressing cells are effective for the inhibition of the growth of melanoma and Ehrlich tumors. Macroencapsulation of engineered cells is therefore a reliable platform for the refinement of innovative therapeutic strategies against tumors. PMID:20196841
Anti-tumor therapy with macroencapsulated endostatin producer cells.
Rodrigues, Danielle B; Chammas, Roger; Malavasi, Natália V; da Costa, Patrícia L N; Chura-Chambi, Rosa M; Balduino, Keli N; Morganti, Ligia
2010-03-02
Theracyte is a polytetrafluoroethylene membrane macroencapsulation system designed to induce neovascularization at the tissue interface, protecting the cells from host's immune rejection, thereby circumventing the problem of limited half-life and variation in circulating levels. Endostatin is a potent inhibitor of angiogenesis and tumor growth. Continuous delivery of endostatin improves the efficacy and potency of the antitumoral therapy. The purpose of this study was to determine whether recombinant fibroblasts expressing endostatin encapsulated in Theracyte immunoisolation devices can be used for delivery of this therapeutic protein for treatment of mice bearing B16F10 melanoma and Ehrlich tumors. Mice were inoculated subcutaneously with melanoma (B16F10 cells) or Ehrlich tumor cells at the foot pads. Treatment began when tumor thickness had reached 0.5 mm, by subcutaneous implantation of 107 recombinant encapsulated or non-encapsulated endostatin producer cells. Similar melanoma growth inhibition was obtained for mice treated with encapsulated or non-encapsulated endostatin-expressing cells. The treatment of mice bearing melanoma tumor with encapsulated endostatin-expressing cells was decreased by 50.0%, whereas a decrease of 56.7% in tumor thickness was obtained for mice treated with non-encapsulated cells. Treatment of Ehrlich tumor-bearing mice with non-encapsulated endostatin-expressing cells reduced tumor thickness by 52.4%, whereas lower tumor growth inhibition was obtained for mice treated with encapsulated endostatin-expressing cells: 24.2%. Encapsulated endostatin-secreting fibroblasts failed to survive until the end of the treatment. However, endostatin release from the devices to the surrounding tissues was confirmed by immunostaining. Decrease in vascular structures, functional vessels and extension of the vascular area were observed in melanoma microenvironments. This study indicates that immunoisolation devices containing endostatin-expressing cells are effective for the inhibition of the growth of melanoma and Ehrlich tumors.Macroencapsulation of engineered cells is therefore a reliable platform for the refinement of innovative therapeutic strategies against tumors.
Maiorana, Carlo; Poli, Pier Paolo; Beretta, Mario
2018-05-21
The aim of the present case report was to show the 17-year hard and soft tissues stability of guided bone regeneration procedure associated with dental implants insertion. A 52-year-old male patient presented with a partial edentulism in the upper right maxilla. A graft consisting of deproteinized bovine bone mineral and autogenous bone stabilized by a non-resorbable expanded polytetrafluoroethylene membrane was used to reconstruct the missing bone applying the biological principles of guided bone regeneration. Dental implants were inserted simultaneously in a prosthetically driven position. Soft tissues were managed with a coronally positioned palatal sliding flap technique to obtain a primary intention healing. The healing proceeded uneventfully, and after 8 months the re-entry procedure was carried out. The defect was three-dimensionally filled by newly formed bone in an ongoing maturation phase. The regenerated bone appeared strictly integrated within the surrounding hard tissue and well vascularized. Temporary crowns were left in situ for 6 months, and definitive metal-ceramic definitive prosthesis were finally cemented and delivered to the patient. No complications occurred during the follow-up period. Clinical follow-up recalls were planned yearly, while radiological exams consisting of orthopantomographs and intra-oral radiographs were performed at 1 year, 8 years, 12 years, and 17 years after the implants insertion. The latest follow-up visit performed after 17 years from the bone augmentation procedure showed clinically stable gingival levels. No radiographic signs of peri-implantitis were observed. Mesial and distal marginal bone levels remained almost unchanged within the physiological threshold. This case report highlighted the effectiveness of the guided bone regeneration technique over a long-term follow-up. Interestingly, the use of a palatal sliding flap repositioned coronally provided sufficient amount of buccal keratinized mucosa. This may had improved the clinical stability of soft tissues preventing at the same time the likelihood of developing peri-implant disease.
Functionalized Materials From Elastomers to High Performance Thermoplastics
DOE Office of Scientific and Technical Information (OSTI.GOV)
Salazar, Laura Ann
Synthesis and incorporation of functionalized materials continues to generate significant research interest in academia and in industry. If chosen correctly, a functional group when incorporated into a polymer can deliver enhanced properties, such as adhesion, water solubility, thermal stability, etc. The utility of these new materials has been demonstrated in drug-delivery systems, coatings, membranes and compatibilizers. Two approaches exist to functionalize a material. The desired moiety can be added to the monomer either before or after polymerization. The polymers used range from low glass transition temperature elastomers to high glass transition temperature, high performance materials. One industrial example of themore » first approach is the synthesis of Teflon(reg. sign). Poly(tetrafluoroethylene) (PTFE or Teflon(reg. sign)) is synthesized from tetrafluoroethylene, a functionalized monomer. The resulting material has significant property differences from the parent, poly(ethylene). Due to the fluorine in the polymer, PTFE has excellent solvent and heat resistance, a low surface energy and a low coefficient of friction. This allows the material to be used in high temperature applications where the surface needs to be nonabrasive and nonstick. This material has a wide spread use in the cooking industry because it allows for ease of cooking and cleaning as a nonstick coating on cookware. One of the best examples of the second approach, functionalization after polymerization, is the vulcanization process used to make tires. Natural rubber (from the Hevea brasiliensis) has a very low glass transition temperature, is very tacky and would not be useful to make tires without synthetic alteration. Goodyear's invention was the vulcanization of polyisoprene by crosslinking the material with sulfur to create a rubber that was tough enough to withstand the elements of weather and road conditions. Due to the development of polymerization techniques to make cis-polyisoprene, natural rubber is no longer needed for the manufacturing of tires, but vulcanization is still utilized.« less
Henry, Barbara J; Carlin, Joseph P; Hammerschmidt, Jon A; Buck, Robert C; Buxton, L William; Fiedler, Heidelore; Seed, Jennifer; Hernandez, Oscar
2018-05-01
Per- and polyfluoroalkyl substances (PFAS) are a group of fluorinated substances that are in the focus of researchers and regulators due to widespread presence in the environment and biota, including humans, of perfluorooctane sulfonate (PFOS) and perfluorooctanoic acid (PFOA). Fluoropolymers, high molecular weight polymers, have unique properties that constitute a distinct class within the PFAS group. Fluoropolymers have thermal, chemical, photochemical, hydrolytic, oxidative, and biological stability. They have negligible residual monomer and oligomer content and low to no leachables. Fluoropolymers are practically insoluble in water and not subject to long-range transport. With a molecular weight well over 100 000 Da, fluoropolymers cannot cross the cell membrane. Fluoropolymers are not bioavailable or bioaccumulative, as evidenced by toxicology studies on polytetrafluoroethylene (PTFE): acute and subchronic systemic toxicity, irritation, sensitization, local toxicity on implantation, cytotoxicity, in vitro and in vivo genotoxicity, hemolysis, complement activation, and thrombogenicity. Clinical studies of patients receiving permanently implanted PTFE cardiovascular medical devices demonstrate no chronic toxicity or carcinogenicity and no reproductive, developmental, or endocrine toxicity. This paper brings together fluoropolymer toxicity data, human clinical data, and physical, chemical, thermal, and biological data for review and assessment to show that fluoropolymers satisfy widely accepted assessment criteria to be considered as "polymers of low concern" (PLC). This review concludes that fluoropolymers are distinctly different from other polymeric and nonpolymeric PFAS and should be separated from them for hazard assessment or regulatory purposes. Grouping fluoropolymers with all classes of PFAS for "read across" or structure-activity relationship assessment is not scientifically appropriate. Integr Environ Assess Manag 2018;14:316-334. © 2018 The Authors. Integrated Environmental Assessment and Management published by Wiley Periodicals, Inc. on behalf of Society of Environmental Toxicology & Chemistry (SETAC). © 2018 The Authors. Integrated Environmental Assessment and Management published by Wiley Periodicals, Inc. on behalf of Society of Environmental Toxicology & Chemistry (SETAC).
Jha, Virendra Kumar; Wydoski, Duane S.
2003-01-01
A method for the isolation of 20 parent organophosphate pesticides and 5 pesticide degradates from bottom-sediment samples is described. The compound O-ethyl-O-methyl-S-proplyphosphorothioate is reported as an estimated concentration because of variable performance. In this method, the sediment samples are centrifuged to remove excess waster mixed with anhydrous sodium sulfate and Soxhlet extracted overnight with dichloromethane (93 percent) and methanol (7 percent). The extract is concentrated and then filtered through a 0.2-micrometer polytetrafluoroethylene membrane syringe filter. An aliquot of the sample extract is quantitatively injected onto two polystyrene-divinylbenzene gel-permeation chromatographic columns connected in series. The compounds are eluted with dichloromethane and a fraction is collected for analysis, with some coextracted interferences, including elemental sulfur, separated and discarded. The aliquot is concentrated and solvent exchanged to ethyl acetate. The extract is analyzed by dual capillary-column gas chromatography with flame photometric detection. Single-operator method detection limits in sodium sulfate matrix samples ranged from 0.81 to 2 micrograms per kilogram. Method performance was validated by spiking all compounds into three different solid matrices (sodium sulfate, bed sediment from Clear Creek, and bed sediment from Evergreen Lake) at three different concentrations. Eight replicates were analyzed at each concentration in each matrix. Mean recoveries of method compounds spiked in Clear Creek samples ranged from 43 to 110 percent, and those in Evergreen Lake samples ranged from 62 to 118 percent for all pesticides. Mean recoveries of method compounds spiked in reagent sodium sulfate samples ranged from 41 to 101 percent for all pesticides. The only exception was O-ethyl-O-methyl-S-propylphosphorothioate, which had an average recovery of 35 percent, and, thus, sample concentration is reported as estimated ('E' remark code).
The use of an ion-beam source to alter the surface morphology of biological implant materials
NASA Technical Reports Server (NTRS)
Weigand, A. J.
1978-01-01
An electron bombardment, ion thruster was used as a neutralized-ion beam sputtering source to texture the surfaces of biological implant materials. Scanning electron microscopy was used to determine surface morphology changes of all materials after ion-texturing. Electron spectroscopy for chemical analysis was used to determine the effects of ion texturing on the surface chemical composition of some polymers. Liquid contact angle data were obtained for ion textured and untextured polymer samples. Results of tensile and fatigue tests of ion-textured metal alloys are presented. Preliminary data of tissue response to ion textured surfaces of some metals, polytetrafluoroethylene, alumina, and segmented polyurethane were obtained.
Development and evaluation of thin semi-rigid cables for superconducting detectors
NASA Astrophysics Data System (ADS)
Kasai, Soichi; Kushino, Akihiro
2015-03-01
We are developing semi-rigid cables for accurate readout of superconducting radiation/particle detectors and other low temperature experiments. The center conductor with a diameter of 0.86 mm is separated with seamless metal outer conductor by dielectric material, polytetrafluoroethylene. We used various metal materials with low thermal conductivity for the electrical conductors such as stainless-steel, cupro-nickel, brass, beryllium-copper, phosphor-bronze, niobium-titanium, and niobium. In addition to the conventional semi-rigid cables, low-pass-filter-type cables were manufactured and evaluated to cut the high frequency noise into superconducting detectors. We measured their low thermal conductance and attenuation property up to 10GHz below the liquid helium temperature.
Development of semi-rigid cables for low temperature superconducting detectors
NASA Astrophysics Data System (ADS)
Kushino, Akihiro; Kasai, Soichi
We are developing semi-rigid cables for accurate readout of superconducting radiation/particle detectors and other low temperature experiments. The center conductor with a diameter of 0.86 mm is separated with seamless metal outer conductor by dielectric material, polytetrafluoroethylene. We used various metal materials with low thermal conductivity for the electrical conductors such as stainless-steel, cupro-nickel, brass, beryllium-copper, phosphor-bronze, niobium-titanium, and niobium. In addition to the conventional semi-rigid cables, low-pass-filter type cables were manufactured and evaluated to cut the high frequency noise into superconducting detectors. We measured their low thermal conductance and attenuation property up to 10 GHz below the liquid helium temperature.
A polymer driveshaft for use in orbital and rotational atherectomy
NASA Astrophysics Data System (ADS)
Grothe, Preston Lee
Driveshafts used in atherectomy medical devices are often comprised of coiled or braided metal wires. These constructions are designed to tolerate delivery through tortuous vessels and can endure high speed rotation used during activation of the atherectomy treatment. This research investigated polymer driveshaft designs, which were comprised of polymer inner and outer layers, and coiled or braided stainless steel wires. The polymer driveshaft materials included polyimide, nylon 12, and polytetrafluoroethylene (PTFE). Mechanical testing of polymer driveshafts was conducted to determine material response in bending, tension, compression, and torsion. The polymer driveshaft test results were then compared with current coiled metal wire driveshaft constructions. The investigation identified polymer driveshaft options that could feasibly work in an atherectomy application.
Compressive Properties of PTFE/Al/Ni Composite Under Uniaxial Loading
NASA Astrophysics Data System (ADS)
Wang, Huai-xi; Li, Yu-chun; Feng, Bin; Huang, Jun-yi; Zhang, Sheng; Fang, Xiang
2017-05-01
To investigate the mechanical properties of pressed and sintered PTFE/Al/Ni (polytetrafluoroethylene/aluminum/nickel) composite, uniaxial quasi-static and dynamic compression experiments were conducted at strain rates from 10-2 to 3 × 103/s. The prepared samples were tested by an electrohydraulic press with 300 kN loading capacity and a split Hopkinson pressure bar (SHPB) device at room temperature. Experimental results show that PTFE/Al/Ni composite exhibits evident strain hardening and strain rate hardening. Additionally, a bilinear relationship between stress and {{log(}}\\dot{ɛ} ) is observed. The experimental data were fit to Johnson-Cook constitutive model, and the results are in well agreement with measured data.
Dependence of triboelectric charging behavior on material microstructure
NASA Astrophysics Data System (ADS)
Wang, Andrew E.; Gil, Phwey S.; Holonga, Moses; Yavuz, Zelal; Baytekin, H. Tarik; Sankaran, R. Mohan; Lacks, Daniel J.
2017-08-01
We demonstrate that differences in the microstructure of chemically identical materials can lead to distinct triboelectric charging behavior. Contact charging experiments are carried out between strained and unstrained polytetrafluoroethylene samples. Whereas charge transfer is random between samples of identical strain, when one of the samples is strained, systematic charge transfer occurs. No significant changes in the molecular-level structure of the polymer are observed by XRD and micro-Raman spectroscopy after deformation. However, the strained surfaces are found to exhibit void and craze formation spanning the nano- to micrometer length scales by molecular dynamics simulations, SEM, UV-vis spectroscopy, and naked-eye observations. This suggests that material microstructure (voids and crazes) can govern the triboelectric charging behavior of materials.
Micro- and Nano-Scale Fabrication of Fluorinated Polymers by Direct Etching Using Focused Ion Beam
NASA Astrophysics Data System (ADS)
Fukutake, Naoyuki; Miyoshi, Nozomi; Takasawa, Yuya; Urakawa, Tatsuya; Gowa, Tomoko; Okamoto, Kazumasa; Oshima, Akihiro; Tagawa, Seiichi; Washio, Masakazu
2010-06-01
Micro- and nano-scale fabrications of various fluorinated polymers were demonstrated by direct maskless etching using a focused ion beam (FIB). The etching rates of perfluorinated polymers, such as poly(tetrafluoroethylene) (PTFE), poly(tetrafluoroethylene-co-hexafluoropropylene) (FEP), poly(tetrafluoroethylene-co-perfluoroalkoxyvinylether) (PFA), were about 500-1000 times higher than those of partially fluorinated polymers, such as poly(tetrafluoroethylene-co-ethylene) (ETFE) and poly(vinilydene-fluoride) (PVdF). Controlled high quality and high aspect-ratio nanostructures of spin-coated cross-linked PTFE were obtained without solid debris. The height and diameter of the fibers were about 1.5 µm and 90 nm, respectively. Their aspect ratio was about 17.
Micro- and Nano-Scale Fabrication of Fluorinated Polymers by Direct Etching Using Focused Ion Beam
NASA Astrophysics Data System (ADS)
Naoyuki Fukutake,; Nozomi Miyoshi,; Yuya Takasawa,; Tatsuya Urakawa,; Tomoko Gowa,; Kazumasa Okamoto,; Akihiro Oshima,; Seiichi Tagawa,; Masakazu Washio,
2010-06-01
Micro- and nano-scale fabrications of various fluorinated polymers were demonstrated by direct maskless etching using a focused ion beam (FIB). The etching rates of perfluorinated polymers, such as poly(tetrafluoroethylene) (PTFE), poly(tetrafluoroethylene-co-hexafluoropropylene) (FEP), poly(tetrafluoroethylene-co-perfluoroalkoxyvinylether) (PFA), were about 500-1000 times higher than those of partially fluorinated polymers, such as poly(tetrafluoroethylene-co-ethylene) (ETFE) and poly(vinilydene-fluoride) (PVdF). Controlled high quality and high aspect-ratio nanostructures of spin-coated cross-linked PTFE were obtained without solid debris. The height and diameter of the fibers were about 1.5 μm and 90 nm, respectively. Their aspect ratio was about 17.
Femtosecond laser ablated durable superhydrophobic PTFE sheet for oil/water separation
NASA Astrophysics Data System (ADS)
Li, Wentao; Yang, Qing; Chen, Feng; Yong, Jiale; Fang, Yao; Huo, Jinglan
2017-02-01
Femtosecond laser microfabrication has been attracting increasing interest of researchers in recent years, and been applied on interface science to control the wettability of solid surfaces. Herein, we fabricate a kind of rough microstructures on polytetrafluoroethylene (PTFE) sheet by femtosecond laser. The femtosecond laser ablated surfaces show durable superhydrophobicity and ultralow water adhesion even after storing in a harsh environment for a long time, including strong acid, strong alkali, and high temperature. A penetrating microholes array was further generated on the rough superhydrophobic PTFE sheet by a subsequent mechanical drilling process. The as-prepared material was successfully applied in the field of oil/water separation due to the inverse superhydrophobicity and superoleophilicity.
Apparatus for inspecting piping
Zollingger, W.T.; Appel, D.K.; Park, L.R.
1995-03-21
An inspection rabbit is described for inspecting piping systems having severe bends therein. The rabbit consists of a flexible, modular body containing a miniaturized eddy current inspection probe, a self-contained power supply for proper operation of the rabbit, an outer surface that allows ease of movement through piping systems and means for transmitting data generated by the inspection device. The body is preferably made of flexible polyvinyl chloride (PVC) tubing or, alternatively, silicone rubber with a shrink wrapping of polytetrafluoroethylene (TEFLON{trademark}). The body is formed to contain the power supply, preferably a plurality of batteries, and a spool of communication wire that connects to a data processing computer external to the piping system. 6 figures.
Multiphase Equations of State for Polymer Materials at High Dynamic Pressures
NASA Astrophysics Data System (ADS)
Khishchenko, Konstantin V.
2015-06-01
Equations of state for materials over a wide range of pressures and temperatures are necessary for numerical simulations of shock-wave processes in condensed matter. Accuracy of calculation results is determined mainly by adequacy of equation of state of a medium. In this work, a new multiphase equation-of-state model is proposed with taking into account the polymorphic phase transformations, melting and evaporation. Thermodynamic calculations are carried out for 2 polymer materials (polymethylmethacrylate and polytetrafluoroethylene) in a broad region of the phase diagram. Obtained results are presented in comparison with available data of experiments at high dynamic pressures in shock and release waves. This work is supported by RSF, Grant 14-50-00124.
NASA Astrophysics Data System (ADS)
Parke, L.; Hooper, I. R.; Hicken, R. J.; Dancer, C. E. J.; Grant, P. S.; Youngs, I. J.; Sambles, J. R.; Hibbins, A. P.
2013-10-01
A cold-pressing technique has been developed for fabricating composites composed of a polytetrafluoroethylene-polymer matrix and a wide range of volume-fractions of MnZn-ferrite filler (0%-80%). The electromagnetic properties at centimetre wavelengths of all prepared composites exhibited good reproducibility, with the most heavily loaded composites possessing simultaneously high permittivity (180 ± 10) and permeability (23 ± 2). The natural logarithm of both the relative complex permittivity and permeability shows an approximately linear dependence with the volume fraction of ferrite. Thus, this simple method allows for the manufacture of bespoke materials required in the design and construction of devices based on the principles of transformation optics.
The atomic nature of polymer-metal interactions in adhesion, friction and wear
NASA Technical Reports Server (NTRS)
Buckley, D. H.; Brainard, W. A.
1973-01-01
Adhesion experiments with polytetra-fluoroethylene (PTFE) and polyimide contacting tungsten indicate that the polymers bond chemically to the clean metal surface. Polymer chain fragments which transfer to the surface of tungsten in field ion microscopy adhesion studies are highly oriented. Auger emission spectroscopy of PTFE transfer films to various metal surfaces indicates that the PTFE is bonded to the metal surface via the carbon atom. With PTFE in sliding contact with different orientations of aluminum, metal orientation is found to influence surfaces in sliding. The lowest friction and least amount of surface damage is detected on the highest atomic density (111) plane. The friction process itself can initiate polymer film formation from simple organic molecules.
Saxon, Richard R; Chervu, Arun; Jones, Paul A; Bajwa, Tanvir K; Gable, Dennis R; Soukas, Peter A; Begg, Richard J; Adams, John G; Ansel, Gary M; Schneider, Darren B; Eichler, Charles M; Rush, Michael J
2013-02-01
To evaluate the performance of a heparin-bonded, expanded polytetrafluoroethylene (ePTFE)-lined nitinol endoprosthesis in the treatment of long-segment occlusive disease of the femoropopliteal artery (FPA) and to identify factors associated with loss of patency. In a single-arm, prospective, 11-center study (VIPER [Gore Viabahn Endoprosthesis with Heparin Bioactive Surface in the Treatment of Superficial Femoral Artery Obstructive Disease] trial), 119 limbs (113 patients; 69 men; mean age, 67 y), including 88 with Rutherford category 3-5 disease and 72 with Inter-Society Consensus for the Management of Peripheral Arterial Disease (TASC II) C or D lesions of the FPA, underwent stent graft implantation. The mean lesion length was 19 cm; 56% of lesions were occlusions. Follow-up evaluations included color duplex ultrasonography in all patients, with patency defined as a peak systolic velocity ratio< 2.5. At 12 months, Rutherford category and ankle-brachial index (ABI) were significantly improved (mean category improvement, 2.4; ABI increased from 0.6±0.2 to 0.9±0.19; P<.0001). Primary and secondary patency rates were 73% and 92%. The primary patency for devices oversized<20% at the proximal landing zone was 88%, whereas the primary patency for devices oversized by>20% was 70% (P = .047). Primary patency was not significantly affected by device diameter (5 vs 6 vs 7 mm) or lesion length (≤20 cm vs>20 cm). The 30-day major adverse event rate was 0.8%. The heparin-bonded, ePTFE/nitinol stent graft provided clinical improvement and a primary patency rate of 73% at 1 year in the treatment of long-segment FPA disease. Careful sizing of the device relative to vessel landing zones is essential for achieving optimal outcomes. Copyright © 2013 SIR. Published by Elsevier Inc. All rights reserved.
AbuRahma, Ali F.; Hopkins, Eric S.; Robinson, Patrick A.; Deel, John T.; Agarwal, Samir
2003-01-01
Objective To compare the late clinical outcome and incidence of recurrent stenosis after carotid endarterectomy (CEA) with polytetrafluoroethylene (PTFE) versus Hemashield patching. Summary Background Data Several randomized trials have confirmed the advantages of patching over primary closure when performing CEA. Methods Two hundred CEAs (180 patients) were randomized into 100 with PTFE patching and 100 with Hemashield. All patients underwent postoperative color duplex ultrasounds at 1, 6, and 12 months, and every year thereafter. The mean follow-up was 26 months. Kaplan-Meier analysis was used to estimate the risk of re-stenosis, stroke, and stroke-free survival. A multivariate analysis of various risk factors was also done. Results Demographic and clinical characteristics were similar in both groups. The incidence of all ipsilateral strokes (early and late) was 8% (7% perioperative) for Hemashield versus 0% for PTFE patching. Both groups had similar mortality rates. The cumulative stroke-free rates at 6, 12, 24, and 36 months were 93%, 93%, 93%, and 89% for Hemashield versus 100%, 100%, 100%, and 100% for PTFE patching. The cumulative stroke-free survival rates at 6, 12, 24, and 36 months were 90%, 89%, 87%, and 79% for Hemashield versus 98%, 98%, 92%, and 92% for PTFE patching. Kaplan-Meier analysis also showed that freedom from 50% or greater re-stenosis at 6, 12, 24, and 36 months was 89%, 81%, 73%, and 66% for Hemashield versus 100%, 100%, 100%, and 92% for PTFE. Similarly, the freedom from 70% or greater re-stenosis at 6, 12, 24, and 36 months was 93%, 91%, 86%, and 78% for Hemashield versus 100%, 100%, 100%, and 100% for PTFE. Univariate and multivariate analyses of demographic and preoperative risk factors showed that only Hemashield was significantly associated with a higher incidence of 70% or greater recurrent stenosis. Conclusions PTFE patching was superior to Hemashield in lowering the incidence of postoperative ipsilateral strokes and late recurrent stenosis. PMID:12796586
DOE Office of Scientific and Technical Information (OSTI.GOV)
Selvakumar, N.; Barshilia, Harish C.; Rajam, K. S.
2010-07-15
We have studied the effect of substrate roughness on the wettability and the apparent surface free energy (SFE) of sputter deposited polytetrafluoroethylene (PTFE) coatings deposited on untreated glass (average roughness, R{sub a}=2.0 nm), plasma etched glass (R{sub a}=7.4 nm), and sandblasted glass (R{sub a}=4500 nm) substrates. The wettability of the PTFE coatings deposited on substrates with varying roughnesses was evaluated by measuring the apparent contact angle (CA) using a series of probe liquids from nonpolar aprotic to polar protic. The wettability measurements indicate that an apparent water CA of 152 deg. with a sliding angle of 8 deg. was achievedmore » for PTFE coatings deposited on a substrate with R{sub a}=4500 nm. The superhydrophobicity observed in these coatings is attributed to the presence of dual scale roughness, densely packed microstructure and the presence of CF{sub 3} groups. Unlike the bulk PTFE which is mainly dispersive, the sputter deposited PTFE coatings are expected to have some degree of polar component due to the plasma treatment. In order to calculate the dispersive SFE of PTFE coatings, we have used the Girifalco-Good-Fowkes (GGF) method and validated it with the Zisman model. Furthermore, the Owens-Wendt model has been used to calculate the dispersive and the polar components of the apparent SFE of the PTFE coatings. These results are further corroborated using the Fowkes method. Finally, an ''equation of state'' theory proposed by Neumann has been used to calculate the apparent SFE values of the PTFE coatings. The results indicate that the apparent SFE values of the PTFE coatings obtained from the Owens-Wendt and the Fowkes methods are comparable to those obtained from the Neumann's method. The analyses further demonstrate that the GGF and the Zisman methods underestimate the apparent SFE values of the sputter deposited PTFE coatings.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chung, Hwan-Hoon, E-mail: chungmic@korea.ac.kr; Lee, Seung Hwa; Cho, Sung Bum
The aim of this study was to determine the feasibility of using a newly designed polytetrafluoroethylene (PTFE)-covered metallic stent in the ureter by comparing its effectiveness with that of the noncovered stent in a canine model. We placed 14 stents in the ureters of seven mongrel dogs that weighed 30-40 kg each. The covered and noncovered stents were deployed in the right and left ureters, respectively, of six dogs. In the seventh dog, a covered stent and a double-J catheter were inserted in the right ureter, and a covered stent only was inserted in the left ureter. The first sixmore » dogs were sacrificed at 5, 10, and 15 weeks after deployment of the stents (two for each follow-up period), and the seventh dog was sacrificed at 30 weeks. There was no migration or poor expansion of any of the stents observed on plain radiography. On intravenous pyelogram and retrograde pyelogram, all of the covered stents at each follow-up period had patent lumens at the stented segments without hydronephrosis, and the passage of contrast material through it was well preserved. The noncovered stents in the dogs sacrificed at 5 and 10 weeks and one of the two dogs sacrificed at 15 weeks showed near-complete occlusion of the stent lumen due to ingrowth of the soft tissue, and severe hydronephrosis was also noted. The noncovered stent in the other dog sacrificed at 15 weeks showed the passage of contrast material without hydronephrosis, but the lumen of the stent was still nearly occluded by the soft tissue. There was no evidence of hydronephrosis or passage disturbance of the contrast material in both ureters of the dog sacrificed at 30 weeks. We conclude that the newly designed PTFE-covered stent effectively prevented the luminal occlusion caused by urothelial hyperplasia compared to the near-total occlusion of the noncovered stents, and no migration of the covered stents was noted.« less
Lerdsirisopon, Sopon; Frisella, Margaret M; Matthews, Brent D; Deeken, Corey R
2011-12-01
This study aimed to determine whether the strength and extensibility of hernia repair materials are negatively influenced by the application of helical titanium tacks. This study evaluated 14 meshes including bare polypropylene, macroporous polytetrafluoroethylene, absorbable barrier, partially absorbable mesh, and expanded polytetrafluoroethylene materials. Each mesh provided 15 specimens, which were prepared in 7.5 × 7.5-cm squares. Of these, 5 "undamaged" specimens were subjected to ball-burst testing to determine their biomechanical properties before application of helical titanium tacks (ProTack). To 10 "damaged" specimens 7 tacks were applied 1 cm apart in a 3.5-cm-diameter circle using a tacking force of 25 to 28 N. The tacks were removed from five of the specimens before ball-burst testing and left intact in the remaining five specimens. The application of tacks had no effect on the tensile strength of Dualmesh, ProLite Ultra, Infinit, Ultrapro, C-QUR Lite (<6 in.), Prolene Soft, or Physiomesh, but the tensile strengths were reduced for Bard Mesh, C-QUR, ProLite, and C-QUR Lite (>6 in.). Most of the meshes did not exhibit significantly different tensile strengths between removal of tacks and tacks left intact. Exceptions included C-QUR, Prolene, Ultrapro, and Bard Soft Mesh, which were weaker with removal of tacks than with tacks left intact during the test. Damage due to the application of helical titanium tacks also caused increased strain at a stress of 16 N/cm for all the meshes except C-QUR Lite (>6 in.) and Physiomesh. Many of the meshes evaluated in this study exhibited damage in the form of reduced tensile strength and increased extensibility after the application of tacks compared with the corresponding "undamaged" meshes. Meshes with smaller interstices and larger filaments were influenced negatively by the application of helical titanium tacks, whereas mesh designs with larger interstices and smaller filaments tended to maintain their baseline mechanical properties.
NASA Astrophysics Data System (ADS)
Lequoy, Pauline
Malgre des avancees technologiques indeniables, l'efficacite des implants biomedicaux est encore limitee par les biomateriaux synthetiques qui les composent, notamment en raison de leur incapacite a generer une reponse biologique adequate. En particulier, la guerison tissulaire autour des implants vasculaires reste problematique. Une etude de la litterature a montre que dans le cas des endoprotheses couvertes (tuyaux polymeriques utilises pour la reparation endovasculaire des anevrismes de l'aorte abdominale), le manque de guerison observe s'explique non seulement par l'inertie des biomateriaux utilises mais aussi par le fait que l'implant est insere dans un vaisseau malade favorisant la mort des cellules par apoptose et presentant une depletion cellulaire marquee. L'hypothese a la base de ce projet est qu'un revetement bioactif pourrait ameliorer la guerison et la colonisation de l'implant par les cellules vasculaires et ainsi favoriser l'attachement de l'implant dans le vaisseau malade afin de prevenir les complications a long terme. Dans ce contexte, deux molecules anti-apoptotiques ont ete selectionnees pour developper le revetement, la chondroitine sulfate (CS), un glycosaminoglycane de la matrice extracellulaire, et le facteur de croissance de l'epiderme (EGF) qui possede egalement un role important dans la guerison tissulaire. L'un des defis de ce projet est de preserver la bioactivite de ces molecules lors de leur immobilisation dans un revetement. Pour etablir une preuve de concept, nous avons demontre qu'un revetement CS+EGF obtenu par greffage covalent permet d'ameliorer significativement la survie des cellules vasculaires humaines (cellules musculaires lisses, CMLV, et fibroblastes) sur les materiaux realistes (PET, ePTFE). Apres avoir transfere ce revetement sur des implants commerciaux en ePTFE, des tests in vivo ont demontre une amelioration de la guerison grâce au revetement bioactif, cependant la guerison n'a pas ete totale dans la cavite anevrismale. Pour ameliorer la bioactivite du revetement, un systeme de capture oriente base sur la complementarite de deux peptides (superhelices 'coiled-coil') a ete utilise pour immobiliser l'EGF sur CS. Cette immobilisation orientee a permis une meilleure efficacite de capture, ainsi qu'une augmentation marquee de la survie des CMLV par rapport au greffage covalent aleatoire utilise precedemment. De plus, les travaux realises ont permis l'avancement de la comprehension des proprietes antiadhesives selectives de CS par comparaison avec le dextrane carboxymethyle. Enfin, nous avons demontre que la polyvalence du systeme de capture oriente pour facteurs de croissance permet la co-immobilisation de deux facteurs de croissance, EGF et VEGF (facteur de croissance de l'endothelium vasculaire), et ce a des ratios variables. Les densites surfaciques ont ete optimisees par simple changement de concentration lors de l'incubation. Des etudes cellulaires avec une gamme de ratios EGF/VEGF ont revele un effet synergique des deux facteurs de croissance sur la survie des CMLV et des cellules endotheliales. Les travaux menes ont permis de developper des revetements bioactifs anti-apoptotiques qui ameliorent la survie des cellules vasculaires et constituent une avancee vers la creation d'endoprotheses bioactives. Il apparait egalement que la plateforme d'immobilisation coiled-coil presente un grand potentiel pour la construction de surfaces bioactives complexes et la comprehension du role de differents facteurs de croissance dans les comportements cellulaires.
Biaxial Testing of High-Strength Fabric Improves Design of Inflatable Radar Domes
NASA Technical Reports Server (NTRS)
Krause, David L.; Bartolotta, Paul A.
2001-01-01
Large radar installations around the globe continuously watch the skies, unobtrusively providing security to the United States; these systems have been in active use for the past 50 years. Often situated in extreme environments, the radar dishes require shielding from the harsh elements. Air-inflated domes (over 100 ft in diameter) are one structure of choice for providing this essential protection. The radomes are constructed from highstrength fabric that is strong enough to withstand the inflation pressure, high winds, and other environmental loads, yet transparent to the microwave signal to allow precise radar mapping. This fabric is woven from glass fibers for high strength and embedded in a polytetrafluoroethylene resin matrix, akin to the nonstick coatings used on cookware.
Effect of Aluminum Particle Size on the Impact Initiation of Pressed Ptfe/al Composite Rods
NASA Astrophysics Data System (ADS)
Mock, Willis; Drotar, Jason T.
2007-12-01
A gas gun has been used to investigate the impact initiation of rods of a mixture of 72 wt% PTFE (polytetrafluoroethylene) and 28 wt% aluminum powders. The rods were sabot-launched in vacuum into steel anvils at impact velocities ranging from 468 to 969 m/s. A framing camera was used to observe the time sequence of events following impact. At the lowest impact stress of 25 kbar no light was observed. Above the initiation threshold, the initiation time dropped from 74 μs just above threshold to 14 μs at 64 kbar. These results are compared with earlier rod impact experiments for a similar material in which the only major difference is a smaller aluminum particle size.
Rubartelli, Paolo; Terzi, Giacomo; Borgo, Lorenzo; Giachero, Corinna
2002-03-01
A patient with unstable angina was treated with elective Palmaz-Schatz stent implantation on a focal stenosis of the left circumflex artery. One year later, a large (13 mm in diameter) coronary artery aneurysm was diagnosed at angiography in the stented site. Intravascular ultrasound examination confirmed the presence of a true aneurysm located at the proximal end of the stent. The aneurysm was successfully treated with a Jostent Graft (Jomed Implantate) consisting of two slotted tube stainless steel stents supporting a polytetrafluoroethylene tube. The stent graft was implanted under intravascular ultrasound guidance. The 18-month angiographic follow-up showed good patency of the stent graft and complete exclusion of the aneurysm.
Zhang, Wenlu; Chen, Fengyi; Ma, Wenwen; Rong, Qiangzhou; Qiao, Xueguang; Wang, Ruohui
2018-04-16
A fringe visibility enhanced fiber-optic Fabry-Perot interferometer based ultrasonic sensor is proposed and experimentally demonstrated for seismic physical model imaging. The sensor consists of a graded index multimode fiber collimator and a PTFE (polytetrafluoroethylene) diaphragm to form a Fabry-Perot interferometer. Owing to the increase of the sensor's spectral sideband slope and the smaller Young's modulus of the PTFE diaphragm, a high response to both continuous and pulsed ultrasound with a high SNR of 42.92 dB in 300 kHz is achieved when the spectral sideband filter technique is used to interrogate the sensor. The ultrasonic reconstructed images can clearly differentiate the shape of models with a high resolution.
Auger analysis of films formed on metals in sliding contact with halogenated polymers
NASA Technical Reports Server (NTRS)
Pepper, S. V.
1974-01-01
The use of Auger electron spectroscopy (AES) to search for transferred polymer must contend with the fact that there has been no published work on Auger analysis of polymers. Since this is a new area for AES, the Auger spectra of polymers and of halogenated polymers in particular is discussed. It is shown that the Auger spectra of halogenated polymers have certain characteristics that permit an assessment of whether a polymeric transfer film has been established by sliding contact. The discussion is general and the concepts should be useful in considering the Auger analysis of any polymer. The polymers chosen for this study are the halogenated polymers polytetrafluoroethylene (PTFE), polyvinyl chloride (PVC), and polychlorotrifluorethylene (PCTFE).
Evaluation of pyrolysis and arc tracking on candidate wire insulation designs for space applications
NASA Astrophysics Data System (ADS)
Stueber, Thomas J.; Hammoud, Ahmad; Stavnes, Mark W.; Hrovat, Kenneth
1994-05-01
Polyimide wire insulation has been found to be vulnerable to pyrolization and arc tracking due to momentary short circuit arcing events. This report compares arc tracking susceptibility of candidate insulation configurations for space wiring applications. The insulation types studied in this report were gauge 20 (0.81 mm dia.) hybrid wiring constructions using polyimide, tetrafluoroethylene (TFE), cross-linked ethylene tetrafluoroethylene (XL-ETFE) and/or polytetrafluoroethylene (PTFE) insulations. These constructions were manufactured according to military wiring standards for aerospace applications. Arc track testing was conducted under DC bias and vacuum (10(exp -6) torr). The tests were conducted to compare the various insulation constructions in terms of their resistance to arc tracking restrike. The results of the tests are presented.
Friction coefficient dependence on electrostatic tribocharging
Burgo, Thiago A. L.; Silva, Cristiane A.; Balestrin, Lia B. S.; Galembeck, Fernando
2013-01-01
Friction between dielectric surfaces produces patterns of fixed, stable electric charges that in turn contribute electrostatic components to surface interactions between the contacting solids. The literature presents a wealth of information on the electronic contributions to friction in metals and semiconductors but the effect of triboelectricity on friction coefficients of dielectrics is as yet poorly defined and understood. In this work, friction coefficients were measured on tribocharged polytetrafluoroethylene (PTFE), using three different techniques. As a result, friction coefficients at the macro- and nanoscales increase many-fold when PTFE surfaces are tribocharged, but this effect is eliminated by silanization of glass spheres rolling on PTFE. In conclusion, tribocharging may supersede all other contributions to macro- and nanoscale friction coefficients in PTFE and probably in other insulating polymers. PMID:23934227
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gandini, Roberto; Pipitone, Vincenzo; Konda, Daniel, E-mail: danielkonda@yahoo.com
2005-01-15
A 68-year-old woman presenting with gastrointestinal bleeding (hematocrit 19.3%) and in a critical clinical condition (American Society of Anesthesiologists grade 4) from a giant superior mesenteric artery pseudoaneurysm (196.0 x 131.4 mm) underwent emergency endovascular treatment. The arterial tear supplying the pseudoaneurysm was excluded using a 5.0 mm diameter and 31 mm long monorail expanded polytetrafluoroethylene (ePTFE)-covered self-expanding nitinol stent. Within 6 days of the procedure, a gradual increase in hemoglobin levels and a prompt improvement in the clinical condition were observed. Multislice CT angiograms performed immediately, 5 days, 30 days and 3 months after the procedure confirmed the completemore » exclusion of the pseudoaneurysm.« less
Fundamental ignition study for material fire safety improvement, part 1
NASA Technical Reports Server (NTRS)
Paciorek, K. L.; Zung, L. B.
1970-01-01
The investigation of preignition, ignition, and combustion characteristics of Delrin (acetate terminated polyformaldehyde) and Teflon (polytetrafluoroethylene) resins in air and oxygen are presented. The determination of ignition limits and their dependence on temperature and the oxidizing media, as well as the analyses of the volatiles produced, were studied. Tests were conducted in argon, an inert medium in which only purely pyrolytic reactions can take place, using the stagnation burner arrangement designed and constructed for this purpose. A theoretical treatment of the ignition and combination phenomena was devised. In the case of Delrin the ignition and ignition delays are apparently independent of the gas (air, oxygen) temperatures. The results indicate that hydrogen is the ignition triggering agent. Teflon ignition limits were established in oxygen only.
1D GAS-DYNAMIC SIMULATION OF SHOCK-WAVE PROCESSES VIA INTERNET
DOE Office of Scientific and Technical Information (OSTI.GOV)
Khishchenko, K. V.; Levashov, P. R.; Povarnitsyn, M. E.
2009-12-28
We present a Web-interface for 1D simulation of different shock-wave experiments. The choosing of initial parameters, the modeling itself and output data treatment can be made directly via the Internet. The interface is based upon the expert system on shock-wave data and equations of state and contains both the Eulerian and Lagrangian Godunov hydrocodes. The availability of equations of state for a broad set of substances makes this system a useful tool for planning and interpretation of shock-wave experiments. As an example of simulation with the system, results of modeling of multistep shock loading of potassium between polytetrafluoroethylene and stainlessmore » steel plates are presented in comparison with experimental data from Shakhray et al.(2005).« less
NASA Astrophysics Data System (ADS)
Bowfield, A.; Barrett, D. A.; Alexander, M. R.; Ortori, C. A.; Rutten, F. M.; Salter, T. L.; Gilmore, I. S.; Bradley, J. W.
2012-06-01
The authors report on a modified micro-plasma assisted desorption/ionisation (PADI) device which creates plasma through the breakdown of ambient air rather than utilising an independent noble gas flow. This new micro-PADI device is used as an ion source for ambient mass spectrometry to analyse species released from the surfaces of polytetrafluoroethylene, and generic ibuprofen and paracetamol tablets through remote activation of the surface by the plasma. The mass spectra from these surfaces compare favourably to those produced by a PADI device constructed using an earlier design and confirm that the new ion source is an effective device which can be used to achieve ambient mass spectrometry with improved spatial resolution.
Sea anemone Radianthus macrodactylus--a new source of palytoxin.
Mahnir, V M; Kozlovskaya, E P; Kalinovsky, A I
1992-11-01
A very potent non-protein toxin was isolated from the sea anemone Radianthus macrodactylus with the use of chromatography on polytetrafluoroethylene, CM-Sephadex C-25 and by cation and anion exchange HPLC. The toxin was identified as palytoxin by u.v.-, i.r.- and 500 MHz 1H NMR spectroscopy. Its LD50 was 0.74 +/- 0.29 micrograms/kg by i.v. injection into mice. So far, palytoxin has been associated with zoanthids only. The toxin caused the loss of haemoglobin from erythrocytes but only in about 2 hr after the beginning of incubation, which is characteristic for palytoxin from zoanthids. Sea anemone palytoxin was divided into major and minor components by HPLC. The latter proved to be a product of degradation of palytoxin.
Luminal surface fabrication for cardiovascular prostheses
NASA Technical Reports Server (NTRS)
Deininger, William D. (Inventor); Gabriel, Stephen B. (Inventor)
1988-01-01
A method is provided for forming a mold surface with microscopic upstanding pillars for molding the inside surface of a vascular prostheses (synthetic blood vessel). The mold article is formed from a quantity of Teflon (polytetrafluoroethylene) which has a polished, flat surface on which a gold film has been sputter deposited. A photoresist layer, which cannot adhere directly to Teflon, adheres to the gold. The photoresist is exposed and developed leaving a sputter resistant mask defining the desired pillar locations, and the resulting workpiece is ion etched to form the pillars in the Teflon. A synthetic blood vessel material is cast against the Teflon mold to form blind recesses on the inside of the synthetic blood vessel, with the recesses being of predetermined uniform cross section and present in a predetermined uniform pattern.
Autoclave decomposition method for metals in soils and sediments.
Navarrete-López, M; Jonathan, M P; Rodríguez-Espinosa, P F; Salgado-Galeana, J A
2012-04-01
Leaching of partially leached metals (Fe, Mn, Cd, Co, Cu, Ni, Pb, and Zn) was done using autoclave technique which was modified based on EPA 3051A digestion technique. The autoclave method was developed as an alternative to the regular digestion procedure passed the safety norms for partial extraction of metals in polytetrafluoroethylene (PFA vessel) with a low constant temperature (119.5° ± 1.5°C) and the recovery of elements were also precise. The autoclave method was also validated using two Standard Reference Materials (SRMs: Loam Soil B and Loam Soil D) and the recoveries were equally superior to the traditionally established digestion methods. Application of the autoclave was samples from different natural environments (beach, mangrove, river, and city soil) to reproduce the recovery of elements during subsequent analysis.
Liquid marble as microbioreactor for bioengineering applications
NASA Astrophysics Data System (ADS)
Sarvi, Fatemeh; Jain, Kanika; Alhasan, Layla; Arbatan, Tina; Shen, Wei; Chan, Peggy P. Y.
2015-12-01
This paper reports the use of liquid marbles (LMs) as miniature bioreactors to produce three-dimensional (3D) spheroids including tumor-like spheriods from cancer cells and embryoid bodies (EBs) from stem cells. A liquid marble microbioreactor is prepared by placing a drop of cell suspension onto a polytetrafluoroethylene (PTFE) particle bed. Without the addition of growth factors, suspended EBs from liquid marbles exhibit spontaneous contraction. These results indicate that the liquid marble provides a suitable microenvironment to induce EB formation and spontaneous cardiac differentiation. The EBs were further plated onto gelatin-coated tissue culture dishes. Plated EBs express mature cardiomyocyte marker cardiac troponinT (cTnT), indicating that these EBs have differentiated into functional cardiomyocytes. The cardiomyocytes generated using this liquid marble approach could be useful for transplantation.
NASA Astrophysics Data System (ADS)
Panin, S. V.; Alexenko, V. O.; Buslovich, D. G.; Anh, Nguyen Duc; Qitao, Huang
2018-01-01
Mechanical and tribotechnical characteristics of solid-lubricant and polymer-polymeric composites of UHMWPE were studied for the sake of design extrudable, wear-resistant, self-lubricant polymer mixtures for Additive Manufacturing (AM). Tribotechnical properties of UHMWPE blends with the optimized content of solid lubricant fillers (polytetrafluoroethylene, calcium stearate, molybdenum disulphide, colloidal graphite, boron nitride) were studied under dry sliding friction at different velocities (V = 0.3 and 0.5 m/s) and loads (P = 60 and 140 N). Also, in order to increase strength and wear-resistance of UHMWPE composites they were reinforced with wollastonite microfibers and aluminum metahydroxide AlO (OH) microparticles preliminary treated (functionalized) in polyorganosiloxane. The comparison on measured mechanical and tribotechnical properties are given with interpretation of the mechanisms of observed phenomenon.
Noji, S; Kitamura, N; Yamaguchi, A; Otaki, M; Miki, T; Tamura, H
1991-08-01
We present a surgical case of 41-year-old woman with Scimitar syndrome. Preoperative catheterization showed azygos connection and L-R shunt ratio of 45% without intracardiac malformations. To our knowledge, this combination has not been previously reported. At operation the right single pulmonary vein was found and drained into the inferior vena cava below the diaphragm. Because of counter clockwise rotation of the heart the distance of the scimitar vein and the left atrium was too long for direct anastomosis, a polytetrafluoroethylene tube (10 mm in diameter) was utilized for an extracardiac conduit using cardiopulmonary bypass. Postoperative course was uneventful. We conclude that this technique is effective for this syndrome with a large amount of L-R shunt and a sufficient patency is expected.
Method for producing fluorinated diamond-like carbon films
Hakovirta, Marko J.; Nastasi, Michael A.; Lee, Deok-Hyung; He, Xiao-Ming
2003-06-03
Fluorinated, diamond-like carbon (F-DLC) films are produced by a pulsed, glow-discharge plasma immersion ion processing procedure. The pulsed, glow-discharge plasma was generated at a pressure of 1 Pa from an acetylene (C.sub.2 H.sub.2) and hexafluoroethane (C.sub.2 F.sub.6) gas mixture, and the fluorinated, diamond-like carbon films were deposited on silicon <100>substrates. The film hardness and wear resistance were found to be strongly dependent on the fluorine content incorporated into the coatings. The hardness of the F-DLC films was found to decrease considerably when the fluorine content in the coatings reached about 20%. The contact angle of water on the F-DLC coatings was found to increase with increasing film fluorine content and to saturate at a level characteristic of polytetrafluoroethylene.
Novel Remanufacturing Process of Recycled Polytetrafluoroethylene(PTFE)/GF Laminate
NASA Astrophysics Data System (ADS)
Xi, Z.; Ghita, O. R.; Johnston, P.; Evans, K. E.
2011-01-01
Currently, the PTFE/GF laminate and PTFE PCB manufacturers are under considerable pressure to address the recycling issues due to Waste Electrical and Electronic Equipment (WEEE) Directive, shortage of landfill capacity and cost of disposal. This study is proposing a novel manufacture method for reuse of the mechanical ground PTFE/Glass fibre (GF) laminate and production of the first reconstitute PTFE/GF laminate. The reconstitute PTFE/GF laminate proposed here consists of a layer of recycled sub-sheet, additional layers of PTFE and PTFE coated glass cloth, also covered by copper foils. The reconstitute PTFE/GF laminate showed good dielectric properties. Therefore, there is potential to use the mechanical ground PTFE/GF laminate powder to produce reconstitute PTFE/GF laminate, for use in high frequencies PCB applications.
A new cryostat for precise temperature control
NASA Astrophysics Data System (ADS)
Dong, B.; Zhou, G.; Liu, L. Q.; Zhang, X.; Xiong, L. Y.; Li, Q.
2013-09-01
Gifford-McMahon (GM) cryocoolers are often used in cryostat as cold sources. It has advantages of simple structure and low operating cost as well as disadvantages of vibration and temperature oscillation, which are fatal for some applications that are very sensitive to temperature stability at low temperature. To solve the problem, a thermal analysis model which is used to simulate heat transfer in the cryostat is built and discussed. According to the analysis results, a cryostat that can provide variable temperature (4-20 K) for the accurate temperature control experiments is designed and manufactured. In this cryostat, a polytetrafluoroethylene (PTFE) sheet is used as a thermal damper to reduce the temperature oscillation, with which, the temperature oscillation of the sample cooling holder is less than 4 mK at the 20 K region.
NASA Technical Reports Server (NTRS)
Helmick, Larry S.; Jones, William R., Jr.
1992-01-01
The oxidative stabilities of several perfluoropolyalkyl ethers (PFPAE) with related chemical structures were determined by thermal gravimetric analysis and correlated with their chemical structures. These results show that oxidative stability increases as the number of difluoroformal groups decreases and as trifluoromethyl substituents are added. They are also consistent with a recently proposed intramolecular disproportionation reaction mechanism involving coordination of successive ether oxygens to a Lewis acid. Since polytetrafluoroethylene contains no oxygen, it provides an indication of the upper limit to oxidative stability of PFPAE fluids. These results also show that oxidative decomposition of PFPAE fluids requires the presence of an active metal as well as air. Consequently, it may be possible to minimize decomposition and thus improve oxidative stability by passivating reactive metal surfaces.
Sarkar, S; Salacinski, H J; Hamilton, G; Seifalian, A M
2006-06-01
When autologous vein is unavailable, prosthetic graft materials, particularly expanded polytetrafluoroethylene are used for peripheral arterial revascularisation. Poor long term patency of prosthetic materials is due to distal anastomotic intimal hyperplasia. Intimal hyperplasia is directly linked to shear stress abnormalities at the vessel wall. Compliance and calibre mismatch between native vessel and graft, as well as anastomotic line stress concentration contribute towards unnatural wall shear stress. High porosity reduces graft compliance by causing fibrovascular infiltration, whereas low porosity discourages the development of an endothelial lining and hence effective antithrombogenicity. Therefore, consideration of mechanical properties is necessary in graft development. Current research into synthetic vascular grafts concentrates on simulating the mechanical properties of native arteries and tissue engineering aims to construct a new biological arterial conduit.
TRITIUM EFFECTS ON DYNAMIC MECHANICAL PROPERTIES OF POLYMERIC MATERIALS
DOE Office of Scientific and Technical Information (OSTI.GOV)
Clark, E
2008-11-12
Dynamic mechanical analysis has been used to characterize the effects of tritium gas (initially 1 atm. pressure, ambient temperature) exposure over times up to 2.3 years on several thermoplastics-ultrahigh molecular weight polyethylene (UHMW-PE), polytetrafluoroethylene (PTFE), and Vespel{reg_sign} polyimide, and on several formulations of elastomers based on ethylene propylene diene monomer (EPDM). Tritium exposure stiffened the elastic modulus of UHMW-PE up to about 1 year and then softened it, and reduced the viscous response monotonically with time. PTFE initially stiffened, however the samples became too weak to handle after nine months exposure. The dynamic properties of Vespel{reg_sign} were not affected. Themore » glass transition temperature of the EPDM formulations increased approximately 4 C. following three months tritium exposure.« less
Constitutive Modeling of the Dynamic-Tensile-Extrusion Test of PTFE
NASA Astrophysics Data System (ADS)
Resnyansky, Anatoly; Brown, Eric; Trujillo, Carl; Gray, George
2015-06-01
Use of polymers in the defence, aerospace and industrial application at extreme conditions makes prediction of behaviour of these materials very important. Crucial to this is knowledge of the physical damage response in association with the phase transformations during the loading and the ability to predict this via multi-phase simulation taking the thermodynamical non-equilibrium and strain rate sensitivity into account. The current work analyses Dynamic-Tensile-Extrusion (DTE) experiments on polytetrafluoroethylene (PTFE). In particular, the phase transition during the loading with subsequent tension are analysed using a two-phase rate sensitive material model implemented in the CTH hydrocode and the calculations are compared with experimental high-speed photography. The damage patterns and their link with the change of loading modes are analysed numerically and are correlated to the test observations.
Fluoropolymer Dynamics: Effects of Perfluoromethyl Branches
NASA Astrophysics Data System (ADS)
Eby, R. K.; Holt, D. B.; Farmer, B. L.; Adams, D. D.
1997-03-01
Previous simulations of polytetrafluoroethylene (PTFE) in the solid state showed that the interaction and movement of helix reversals plays an important role in the dynamic behavior of this important polymer. Copolymers of TFE and hexafluoropropylene (HFP), which can be viewed as PTFE with perfluoromethyl (PFM) group branch defects, is also widely used. Molecular mechanics and dynamics calculations have been performed with PTFE chain clusters containing PFM branches to investigate the effect of these defects on the local crystalline environment (and vice versa) and on the motions and interactions of helix reversals. Initial results indicate that helix reversals are attracted to sites of PFM branches in a chain. Such an interaction will impede the motions of helix reversals and have an impact on macroscopic mechanical properties such as resistance to plastic deformation under shear.
Bia, Daniel; Cabrera-Fischer, Edmundo I.; Zócalo, Yanina; Galli, Cintia; Graf, Sebastián; Valtuille, Rodolfo; Pérez-Cámpos, Héctor; Saldías, María; Álvarez, Inés; Armentano, Ricardo L.
2012-01-01
Purpose. To evaluate in chronically haemodialysed patients (CHPs), if: (1) the vascular access (VA) position (upper arm or forearm) is associated with differential changes in upper limb arterial stiffness; (2) differences in arterial stiffness exist between genders associated with the VA; (3) the vascular substitute (VS) of choice, in biomechanical terms, depends on the previous VA location and CHP gender. Methods. 38 CHPs (18 males; VA in upper arm: 18) were studied. Left and right carotid-brachial pulse wave velocity (PWVc-b) was measured. In in vitro studies, PWV was obtained in ePTFE prostheses and in several arterial and venous homografts obtained from donors. The biomechanical mismatch (BM) between CHP native vessel (NV) and VS was calculated. Results/Conclusions. PWVc-b in upper limbs with VA was lower than in the intact contralateral limbs (P < 0.05), and differences were higher (P < 0.05) when the VA was performed in the upper arm. Differences between PWVc-b in upper limbs with VA (in the upper arm) with respect to intact upper limbs were higher (P < 0.05) in males. Independently of the region in which the VA was performed, the homograft that ensured the minimal BM was the brachial artery. The BM was highly dependent on gender and the location in the upper limb in which the VA was performed. PMID:22567282
Kerkhoffs, Wolfgang; Schumacher, Oliver; Meyns, Bart; Verbeken, Erik; Leunens, Veerle; Bollen, Hilde; Reul, Helmut
2004-10-01
The design concept and first in vitro and in vivo results of a long-term implantable ventricular assist device system based on a microaxial blood pump are presented. The blood-immersed parts of the pump consist of a single-stage impeller and a proximally integrated microelectric motor. Both parts are surrounded by a pump housing currently made of polycarbonate to allow visible access to the blood-exposed parts. A titanium inflow cage attached to the tip of the housing is directly implanted into the left ventricular apex. The outflow of the pump is connected to the descending aorta by means of an e-PTFE graft. The overall dimensions of the device are 12 mm in outer diameter and about 50 mm in length. The calculated lifetime of the device is up to 2 years. The system underwent long-term durability tests, hydraulic performance tests, dynamic stability tests, and in vitro hemolysis and thrombogenicity tests. Furthermore, animal tests have been performed in adult Dorset sheep. In a first series, the pump has been placed extracorporeally; in a second series, the pump was completely implanted. Mean duration of the animal experiments of the second series was 31 days (range 8-110 days, n=14); no anticoagulation was administered over the whole test period. Blood data revealed no significant changes in blood cell counts, ionogram, or any other value. No end-organ dysfunction induced by long-term support could be observed, nor did the pathology reveal any evidence of thromboembolic complications.
NASA Astrophysics Data System (ADS)
Barry, Peter R.
Polytetrafluoroethylene (PTFE) is a polymer that has been widely exploited commercially as a result of its low friction, 'non-stick' properties. The polymer has found usage as 'non-stick,' chemically resistant coatings for bearings, valves, rollers and pipe linings with applications in industries ranging from food and chemical processing to construction, automotive and aerospace. The major drawback of PTFE in low friction applications involves its excessive wear rate. For decades, scientists and engineers have sought to improve the polymer's wear resistance while maintaining its low sliding friction by reinforcing the polymer matrix with a host of filler materials ranging from fibril to particulate. In this study, a different approach is taken in which the atomic scale phenomena between two crystalline PTFE surfaces in sliding contact are examined. The goal is to obtain atomic-level insights into PTFE's low friction and high wear rate to aid in the designing of effective polymer based tribological composites for extreme condition applications. To accomplish this, several tribological conditions were varied. These included sliding direction of the two polymer surfaces with respect to their chain alignment, sliding velocity, degree of crystalline phase rigidity, interfacial contact pressure, sample temperature and the presence of fluorocarbon fluids between the two crystalline PTFE surfaces. From these studies, it was found that crystalline PTFE-PTFE sliding demonstrates friction anisotropy. Low friction and molecular wear was observed when sliding in the direction of the chain alignment with high friction and wear behavior dominating when sliding in a direction perpendicular to the chain alignment. For the range of cross-link density (average linear density of 6.2 to 11.1 A) and sliding rate (5 m/s to 20 m/s) explored, a significant change in friction behavior or wear mechanisms was not observed. Under conditions of increased normal load or low temperature however, the frictional force increased linearly. Additionally, the inclusion of fluorocarbon molecular fluids at the sliding interface between the two crystalline PTFE surfaces resulted in a significant decrease in both the friction and wear of the surfaces.
Ahmadi, Fardin; Sparham, Chris; Pawliszyn, Janusz
2017-11-01
In this paper problems associated with preparation of aqueous standard of highly hydrophobic compounds such as partial precipitation, being lost on the surfaces, low solubility in water and limited sample volume for accurate determination of their distribution coefficients are addressed. The following work presents two approaches that utilize blade thin film microextraction (TFME) to investigate partitioning of UV filters and biocides to humic acid (dissolved organic carbon) and sediment. A steady-state concentration of target analytes in water was generated using a flow-through aqueous standard generation (ASG) system. Dialysis membranes, a polytetrafluoroethylene permeation tube, and a frit porous (0.5 μm) coated by epoxy glue were basic elements used for preparation of the ASG system. In the currently presented study, negligible depletion TFME using hydrophilic-lipophilic balance (HLB) and octadecyl silica-based (C18) sorbents was employed towards the attainment of free concentration values of target analytes in the studied matrices. Thin film geometry provided a large volume of extraction phase, which improved the sensitivity of the method towards highly matrix-bound analytes. Extractions were performed in the equilibrium regime so as to prevent matrix effects and with aims to reach maximum method sensitivity for all analytes under study. Partitioning of analytes on dissolved organic carbon (DOC) was investigated in ASG to facilitate large sample volume conditions. Binding percentages and DOC distribution coefficients (Log K DOC ) ranged from 20 to 98% and 3.71-6.72, respectively. Furthermore, sediment-water partition coefficients (K d ), organic-carbon normalized partition coefficients (Log K OC ), and DOC distribution coefficients (Log K DOC ) were investigated in slurry sediment, and ranged from 33 to 2860, 3.31-5.24 and 4.52-5.75 Lkg -1 , respectively. The obtained results demonstrated that investigations utilizing ASG and TFME can yield reliable binding information for compounds with high log K OW values. This information is useful for study of fate, transport, and ecotoxicological effects of UV filters and biocides in aquatic environment. Copyright © 2017 Elsevier Ltd. All rights reserved.
PAH air pollution at a Portuguese urban area: carcinogenic risks and sources identification.
Slezakova, K; Pires, J C M; Castro, D; Alvim-Ferraz, M C M; Delerue-Matos, C; Morais, S; Pereira, M C
2013-06-01
This study aimed to characterize air pollution and the associated carcinogenic risks of polycyclic aromatic hydrocarbon (PAHs) at an urban site, to identify possible emission sources of PAHs using several statistical methodologies, and to analyze the influence of other air pollutants and meteorological variables on PAH concentrations.The air quality and meteorological data were collected in Oporto, the second largest city of Portugal. Eighteen PAHs (the 16 PAHs considered by United States Environment Protection Agency (USEPA) as priority pollutants, dibenzo[a,l]pyrene, and benzo[j]fluoranthene) were collected daily for 24 h in air (gas phase and in particles) during 40 consecutive days in November and December 2008 by constant low-flow samplers and using polytetrafluoroethylene (PTFE) membrane filters for particulate (PM10 and PM2.5 bound) PAHs and pre-cleaned polyurethane foam plugs for gaseous compounds. The other monitored air pollutants were SO2, PM10, NO2, CO, and O3; the meteorological variables were temperature, relative humidity, wind speed, total precipitation, and solar radiation. Benzo[a]pyrene reached a mean concentration of 2.02 ng m(-3), surpassing the EU annual limit value. The target carcinogenic risks were equal than the health-based guideline level set by USEPA (10(-6)) at the studied site, with the cancer risks of eight PAHs reaching senior levels of 9.98 × 10(-7) in PM10 and 1.06 × 10(-6) in air. The applied statistical methods, correlation matrix, cluster analysis, and principal component analysis, were in agreement in the grouping of the PAHs. The groups were formed according to their chemical structure (number of rings), phase distribution, and emission sources. PAH diagnostic ratios were also calculated to evaluate the main emission sources. Diesel vehicular emissions were the major source of PAHs at the studied site. Besides that source, emissions from residential heating and oil refinery were identified to contribute to PAH levels at the respective area. Additionally, principal component regression indicated that SO2, NO2, PM10, CO, and solar radiation had positive correlation with PAHs concentrations, while O3, temperature, relative humidity, and wind speed were negatively correlated.
NASA Astrophysics Data System (ADS)
Mashkov, Yu K.; Ruban, A. S.; Rogachev, E. A.; Chemisenko, O. V.
2018-01-01
Conditions of polymer materials usage containing nanoelements as modifiers significantly affect the requirements for their physic-mechanical and tribological properties. However, the mechanisms of nanoparticles effect to the polymers tribotechnical properties have not been studied enough. The article aim is to analyze the results of studying polytetrafluoroethylene modified with cryptocrystalline graphite and silicon dioxide and to determine the effectiveness of the modification methods used and methods for further improving filled PTFE mechanical and tribotechnical properties. The effect of modifiers to PCM supramolecular structure was analyzed with SEM methods. The results of modifying the PCM samples surface by depositing a copper film with ion-vacuum deposition methods and changing the structural-phase composition and tribological characteristics are considered. The findings make possible to characterize the physicochemical processes under frictional interaction in metal polymer tribosystems.
A Fiber Bragg Grating Temperature Sensor for 2-400 K
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zaynetdinov, Madrakhim; See, Erich M.; Geist, Brian
2015-03-01
We demonstrate fiber optic, multiplexible temperature sensing using a fiber Bragg grating (FBG) with an operational range of 2-400 K, and a temperature resolution better than 10 mK for temperatures < 12 K. This represents a significant reduction in the lowest usable temperature as well as a significant increase in sensitivity at cryogenic temperatures compared with previously reported multiplexible solutions. This is accomplished by mounting the section of the fiber with a FBG on a polytetrafluoroethylene coupon, which has a non-negligible coefficient of thermal expansion down to < 4 K. The sensors exhibit a good stability over multiple temperature cyclesmore » and acceptable sensor-to-sensor repeatability. Possible applications for this sensor include distributed temperature sensing across superconducting elements and cryogenic temperature measurements in environments where electrical measurements are impractical or unsafe.« less
Simulation of Martian dust accumulation on surfaces
NASA Technical Reports Server (NTRS)
Perez-Davis, Marla E.; Gaier, James R.; Kress, Robert; Grimalda, Justus
1990-01-01
Future NASA space missions include the possibility of manned landings and exploration of Mars. Environmental and operational constraints unique to Mars must be considered when selecting and designing the power system to be used on the Mars surface. A technique is described which was developed to simulate the deposition of dust on surfaces. Three kinds of dust materials were studied: aluminum oxide, basalt, and iron oxide. The apparatus was designed using the Stokes and Stokes-Cunningham law for particle fallout, with additional consideration given to particle size and shape. Characterization of the resulting dust films on silicon dioxide, polytetrafluoroethylene, indium tin oxide, diamondlike carbon, and other surfaces are discussed based on optical transmittance measurements. The results of these experiments will guide future studies which will consider processes to remove the dust from surfaces under Martian environmental conditions.
Development of a simple and low cost microbioreactor for high-throughput bioprocessing.
Rahman, Pattanathu K S M; Pasirayi, Godfrey; Auger, Vincent; Ali, Zulfiqur
2009-02-01
A simple microbioreactor for high-throughput bioprocessing made from low cost polymer polytetrafluoroethylene (PTFE) tubes with a working volume of 1.5 ml is described. We have developed a microfluidic system that handles a small population of cells of a model microorganism, Pseudomonas aeruginosa DS10-129. Under the conditions of the microbioreactor, the organism produced extracellular secondary metabolites by using nutrient broth modified with glycerol. Pyocyanins were isolated from the fermented medium as a metabolite of interest. Antibiotic properties of pyocyanin were effective against a number of microorganisms such as Staphylococcus aureus, S. epidermis, Bacillus subtilis, Micrococcus luteus and Saccharomyces cerevisiae. Batch fermentation of the model organism in the microbioreactor was compared to shake-flask and conventional bench fermenter methods. Results obtained from the microbioreactor compared favourably with the conventional processes.
Thermal desorption study of physical forces at the PTFE surface
NASA Technical Reports Server (NTRS)
Wheeler, D. R.; Pepper, S. V.
1987-01-01
Thermal desorption spectroscopy (TDS) of the polytetrafluoroethylene (PTFE) surface was successfully employed to study the possible role of physical forces in the enhancement of metal-PTFE adhesion by radiation. The thermal desorption spectra were analyzed without assumptions to yield the activation energy for desorption over a range of xenon coverage from less than 0.1 monolayer to more than 100 monolayers. For multilayer coverage, the desorption is zero-order with an activation energy equal to the sublimation energy of xenon. For submonolayer coverages, the order for desorption from the unirradiated PTFE surface is 0.73 and the activation energy for desorption is between 3.32 and 3.36 kcal/mol; less than the xenon sublimation energy. The effect of irradiation is to increase the activation energy for desorption to as high as 4 kcal/mol at low coverage.
Thermal desorption study of physical forces at the PTFE surface
NASA Technical Reports Server (NTRS)
Wheeler, D. R.; Pepper, S. V.
1985-01-01
Thermal desorption spectroscopy (TDS) of the polytetrafluoroethylene (PTFE) surface was successfully employed to study the possibile role of physical forces in the enhancement of metal-PTFE adhesion by radiation. The thermal desorption spectra were analyzed without assumptions to yield the activation energy for desorption over a range of xenon coverage from less than 0.1 monolayer to more than 100 monolayers. For multilayer coverage, the desorption is zero-order with an activation energy equal to the sublimation energy of xenon. For submonolayer coverages, the order for desorption from the unirradiated PTFE surface is 0.73 and the activation energy for desorption is between 3.32 and 3.36 kcal/mol; less than the xenon sublimation energy. The effect of irradiation is to increase the activation energy for desorption to as high as 4 kcal/mol at low coverage.
NASA Astrophysics Data System (ADS)
Lappan, Uwe; Geißler, Uwe; Gohs, Uwe; Uhlmann, Steffi
2010-10-01
In this study, the influence of irradiation temperature on mechanical properties of three fluoropolymers and on grafting of styrene into the polymers by the pre-irradiation method was investigated. Electron paramagnetic resonance spectroscopy and infrared spectroscopy were used to characterize the irradiated polymers regarding trapped radical species and changes in the chemical structure, respectively. For poly(tetrafluoroethylene-co-perfluoropropyl vinyl ether) (PFA) the irradiation temperature was found to be an important factor for tensile strength and elongation at break of the pre-irradiated film. No strong effect of irradiation temperature on the mechanical properties was noticed for poly(tetrafluoroethylene-co-ethylene) (ETFE); however the yield of grafting drops at high irradiation temperatures. Finally, mechanical properties of poly(tetrafluoroethylene) (PTFE) were found to be dramatically altered, even if the film was irradiated at elevated temperature.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dooraghi, A. A.; Seetho, I.; Smith, J.. A.
2017-04-27
In this document, we outline an experiment performed at LLNL to evaluate the radiation sensitivity of polytetrafluoroethylene (PTFE) and a PTFE isomer, fluorinated ethylene propylene (FEP). We demonstrate that PTFE, a material currently used for assessing MicroCT system stability, shows higher radiation-dependent change in x-ray attenuation than FEP. Specifically, for a dose of approximately 1.44 x 10 3 Gy, the linear attenuation coefficient (LAC) of PTFE changes by 0.8 ± 0.1 %. During the same irradiation period, the LAC for FEP changes by 0.02 ± 0.1 %, which is within the statistical uncertainty of the measurement. Due to its highermore » resistance to radiation damage, we recommend that LLNL and partner labs operating under the Department of Homeland Security’s Explosives Division (DHS EXD) transition to the use of FEP as a reference material in place of PTFE.« less
Solid spherical glass particle impingement studies of plastic materials
NASA Technical Reports Server (NTRS)
Rao, P. V.; Young, S. G.; Buckley, D. H.
1983-01-01
Erosion experiments on polymethyl methacrylate (PMMA), polycarbonate, and polytetrafluoroethylene (PTFE) were conducted with spherical glass beads impacting at normal incidence. Optical and scanning electron microscopic studies and surface profile measurements were made on specimens at predetermined test intervals. During the initial stage of damage to PMMA and polycarbonate, material expands or builds up above the original surface. However, this buildup disappears as testing progresses. Little or no buildup was observed on PTFE. PTFE is observed to be the most resistant material to erosion and PMMA the least. At low impact pressures, material removal mechanisms are believed to be similar to those for metallic materials. However, at higher pressures, surface melting is indicated at the center of impact. Deformation and fatigue appear to play major roles in the material removal process with possible melting or softening.
Self-discharge performance of Ni-MH battery by using electrodes with hydrophilic/hydrophobic surface
NASA Astrophysics Data System (ADS)
Li, Xiaofeng; Wang, Xiaojie; Dong, Huichao; Xia, Tongchi; Wang, Lizhen; Song, Yanhua
2013-12-01
The polytetrafluoroethylene (PTFE) and carboxymethyl cellulose (CMC) film is separately coated on the surface of the metal hydride (MH) and Ni(OH)2 electrodes to obtain the electrodes with hydrophobic or hydrophilic surface. The effects of the surface treatment on the oxygen and hydrogen evolution from the electrodes are studied by using cyclic voltammetry tests. Although the positive and negative active materials of the Ni-MH batteries show a lower self-decomposition rate after the CMC treatment, the self-discharge rate of the batteries show little change. On the contrary, the self-discharge rate of the batteries decreases from 35.9% to 27.1% by using the PTFE-treated Ni(OH)2 electrodes, which might be related to the suppression of the reaction between NiOOH and H2 by the hydrophobic film.
NASA Astrophysics Data System (ADS)
Yin, Kai; Yang, Shuai; Dong, Xinran; Chu, Dongkai; Duan, Ji-An; He, Jun
2018-06-01
We report a simple, efficient method to fabricate micro/nanoscale hierarchical structures on one side of polytetrafluoroethylene mesh surfaces, using one-step femtosecond laser direct writing technology. The laser-treated surface exhibits superhydrophobicity in air and superaerophilicity in water, resulting in the mesh possessing the hydrophobic/superhydrophobic asymmetrical property. Bubbles can pass through the mesh from the untreated side to the laser-treated side but cannot pass through the mesh in the opposite direction. The asymmetrical mesh can therefore be designed for the directional transportation and continuous collection of gas bubbles in aqueous environments. Furthermore, the asymmetrical mesh shows excellent stability during corrosion and abrasion tests. These findings may provide an efficient route for fabricating a durable asymmetrical mesh for the directional and continuous transport of gas bubbles.
NASA Technical Reports Server (NTRS)
Eigenbrode, J. L.; McAdam, A.; Franz, H.; Freissinet, C.; Bower, H.; Floyd, M.; Conrad, P.; Mahaffy, P.; Feldman, J.; Hurowitz, J.;
2013-01-01
Polytetrafluoroethylene (PTFE or trade name: Teflon by Dupont Co.) has been detected in rocks drilled during terrestrial testing of the Mars Science Laboratory (MSL) drilling hardware. The PTFE in sediments is a wear product of the seals used in the Drill Bit Assemblies (DBAs). It is expected that the drill assembly on the MSL flight model will also shed Teflon particles into drilled samples. One of the primary goals of the Sample Analysis at Mars (SAM) instrument suite on MSL is to test for the presence of martian organics in samples. Complications introduced by the potential presence of PTFE in drilled samples to the SAM evolved gas analysis (EGA or pyrolysisquadrupole mass spectrometry, pyr-QMS) and pyrolysis- gas chromatography mass spectrometry (Pyr- GCMS) experiments was investigated.
NASA Technical Reports Server (NTRS)
Wisander, D. W.; Brewe, D. E.; Scibbe, H. W.
1972-01-01
Ball bearings (40-mm bore) with lead coated, aluminum-bronze retainers were operated successfully in liquid hydrogen at 30,000 rpm under a thrust load of 1780 newtons (400 lb) for running times up to 15 hours. The lead transfer films on the bearing surfaces prevented galling of bearing components. The lead coated retainers used in this investigation show promise for use in the high radiation environments, where polytetrafluoroethylene (PTFE) based materials are not suitable. Failure was a result of the loss of lead lubricant on the retainer-inner-land and ball-pocket surfaces. The longest bearing life (15 hr) was achieved with a lead coating thickness of 50 micrometers (0.002 in.) on the retainer. Other bearings had lives of 2 to 6 hours.
Simulation of Particle Size Effect on Dynamic Properties and Fracture of PTFE-W-Al Composites
NASA Astrophysics Data System (ADS)
Herbold, E. B.; Cai, J.; Benson, D. J.; Nesterenko, V. F.
2007-12-01
Recent investigations of the dynamic compressive strength of cold isostatically pressed composites of polytetrafluoroethylene (PTFE), tungsten (W) and aluminum (Al) powders show significant differences depending on the size of metallic particles. The addition of W increases the density and changes the overall strength of the sample depending on the size of W particles. To investigate relatively large deformations, multi-material Eulerian and arbitrary Lagrangian-Eulerian methods, which have the ability to efficiently handle the formation of free surfaces, were used. The calculations indicate that the increased sample strength with fine metallic particles is due to the dynamic formation of force chains. This phenomenon occurs for samples with a higher porosity of the PTFE matrix compared to samples with larger particle size of W and a higher density PTFE matrix.
Observation of Effectiveness of Clinical Sterilization by CASP-80A Low-Temperature Plasma Sterilizer
NASA Astrophysics Data System (ADS)
Li, Si; Zhang, Yangde; Liu, Weidong
2006-09-01
The influence on the effectiveness of sterilization by low-temperature plasma sterilizer CASP-80A was investigated so as to provide a theoretical basis for reducing medical costs and achieving ideal sterilization effectiveness. To conduct the on-site simulation test, a clinical material sterilization test and a test of the influence of organic substance were conducted, the former by using the representative of Bacillus Stearothermophilus, preparing the bacteria-contaminated carrier through polytetrafluoroethylene (PTFE) simulated hose endoscopes, and the latter by using calf serum as the influence factor of the organic substance. The results show that the CASP-80A low-temperature plasma sterilizer could achieve effective sterilization by either the short-cycle or the long-cycle sterilization method depending on different materials, apparatus, and extent of contamination. The organic substances could influence the effectiveness of sterilization by the low-temperature plasma (H2O2) sterilizer.
High voltage insulation of bushing for HTS power equipment
NASA Astrophysics Data System (ADS)
Kim, Woo-Jin; Choi, Jae-Hyeong; Kim, Sang-Hyun
2012-12-01
For the operation of high temperature superconducting (HTS) power equipments, it is necessary to develop insulating materials and high voltage (HV) insulation technology at cryogenic temperature of bushing. Liquid nitrogen (LN2) is an attractive dielectric liquid. Also, the polymer insulating materials are expected to be used as solid materials such as glass fiber reinforced plastic (GFRP), polytetra-fluoroethylene (PTFE, Teflon), Silicon (Si) rubber, aromatic polyamide (Nomex), EPDM/Silicon alloy compound (EPDM/Si). In this paper, the surface flashover characteristics of various insulating materials in LN2 are studied. These results are studied at both AC and impulse voltage under a non-uniform field. The use of GFRP and Teflon as insulation body for HTS bushing should be much desirable. Especially, GFRP is excellent material not only surface flashover characteristics but also mechanical characteristics at cryogenic temperature. The surface flashover is most serious problem for the shed design in LN2 and operation of superconducting equipments.
Methods of Antimicrobial Coating of Diverse Materials
NASA Technical Reports Server (NTRS)
Akse, James R.; Holtsnider, John T.; Kliestik, Helen
2011-01-01
Methods of coating diverse substrate materials with antimicrobial agents have been developed. Originally intended to reduce health risks to astronauts posed by pathogenic microorganisms that can grow on surfaces in spacecraft, these methods could also be used on Earth for example, to ensure sterility of surgical inserts and other medical equipment. The methods involve, generally, chemical preparation of substrate surfaces to enable attachment of antimicrobial molecules to the substrate surfaces via covalent bonds. Substrate materials that have been treated successfully include aluminum, glass, a corrosion-resistant nickel alloy, stainless steel, titanium, and poly(tetrafluoroethylene). Antimicrobial agents that have been successfully immobilized include antibiotics, enzymes, bacteriocins, bactericides, and fungicides. A variety of linkage chem istries were employed. Activity of antimicrobial coatings against gram-positive bacteria, gram-negative bacteria, and fungi was demonstrated. Results of investigations indicate that the most suitable combination of antimicrobial agent, substrate, and coating method depends upon the intended application.
Fan, Ching-Lin; Shang, Ming-Chi; Li, Bo-Jyun; Lin, Yu-Zuo; Wang, Shea-Jue; Lee, Win-Der; Hung, Bohr-Ran
2015-04-13
This study proposes a two-photomask process for fabricating amorphous indium-gallium-zinc oxide (a-IGZO) thin-film transistors (TFTs) that exhibit a self-aligned structure. The fabricated TFTs, which lack etching-stop (ES) layers, have undamaged a-IGZO active layers that facilitate superior performance. In addition, we demonstrate a bilayer passivation method that uses a polytetrafluoroethylene (Teflon) and SiO₂ combination layer for improving the electrical reliability of the fabricated TFTs. Teflon was deposited as a buffer layer through thermal evaporation. The Teflon layer exhibited favorable compatibility with the underlying IGZO channel layer and effectively protected the a-IGZO TFTs from plasma damage during SiO₂ deposition, resulting in a negligible initial performance drop in the a-IGZO TFTs. Compared with passivation-free a-IGZO TFTs, passivated TFTs exhibited superior stability even after 168 h of aging under ambient air at 95% relative humidity.
Duband, Sébastien; Govin, Alexandre; Dumollard, Jean-Marc; Forest, Fabien; Basset, Thierry; Péoc'h, Michel
2012-01-10
Forensic pathologists are sometimes confronted with microscopic foreign bodies mixed in with soft tissues surrounding wounds and which are thus difficult to identify. This identification, however, could be primordial in investigating a crime and in determining the weapon used. A case of a fatal respiratory distress syndrome due to conjoining suicidal drug intoxication and laryngeal obstruction by a voluminous foreign body giant cell granuloma is presented. The classical histological examination showed exogenous particles in the vocal cord tumor with birefringent qualities. Their analysis with Fourier-Transform infrared (FTIR) spectrometry coupled with infrared microscope allows the determination of their chemical nature as polytetrafluoroethylene and to the diagnosis of teflonoma. This case report put the emphasis on the forensic interest of the FTIR imaging. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.
An all-water-based system for robust superhydrophobic surfaces.
Liu, Mingming; Hou, Yuanyuan; Li, Jing; Tie, Lu; Guo, Zhiguang
2018-06-01
Superhydrophobic surfaces with micro-/nanohierarchical structures are mechanically weak. Generally, organic solvents are used to dissolve or disperse organic adhesives and modifiers to enhance the mechanical strength of superhydrophobic surfaces. In this work, an all-water-based spraying solution is developed for the preparation of robust superhydrophobic surfaces, which contains ZnO nanoparticles, aluminum phosphate as an inorganic adhesive, and polytetrafluoroethylene with low surface energy. The all-water-based system is appreciated for low price and less pollution. Importantly, the prepared superhydrophobic surfaces are durable enough against various harsh conditions (such as UV irradiation for 12 h, pH values from 1 to 13, and temperatures from -10 to 300 °C for 12 h) and physical damages (including sandpaper abrasion and sand impact tests for 50 cycles). In addition, the obtained interfacial materials show promise for practical applications such as anti-icing and oil-water separation. Copyright © 2018 Elsevier Inc. All rights reserved.
NASA Technical Reports Server (NTRS)
Golub, Morton A.; Wydeven, Theodore; Cormia, Robert D.
1989-01-01
The ESCA (electron spectroscopy for chemical analysis) spectra of films of Tedlar, tetrafluoroethylene-hexafluoropropylene copolymer (in the form of a Teflon FEP coating on Kapton H, i.e., Kapton F), and polytetrafluoroethylene (Teflon or Teflon TFE), exposed to atomic oxygen O(3P) either in LEO on the STS-8 Space Shuttle or within or downstream from a radio-frequency oxygen plasma, were compared. The major difference in surface chemistry of Tedlar induced by the various exposures to O(3P) was a much larger uptake of oxygen when etched either in or out of the glow of an O2 plasma than when etched in LEO. In contrast, Kapton F exhibited very little surface oxidation during any of the three different exposures to O(3P), while Teflon was scarcely oxidized.
NASA Astrophysics Data System (ADS)
Spinner, Marlene; Kovalev, Alexander; Gorb, Stanislav N.; Westhoff, Guido
2013-05-01
The West African Gaboon viper (Bitis rhinoceros) is a master of camouflage due to its colouration pattern. Its skin is geometrically patterned and features black spots that purport an exceptional spatial depth due to their velvety surface texture. Our study shades light on micromorphology, optical characteristics and principles behind such a velvet black appearance. We revealed a unique hierarchical pattern of leaf-like microstructures striated with nanoridges on the snake scales that coincides with the distribution of black colouration. Velvet black sites demonstrate four times lower reflectance and higher absorbance than other scales in the UV - near IR spectral range. The combination of surface structures impeding reflectance and absorbing dark pigments, deposited in the skin material, provides reflecting less than 11% of the light reflected by a polytetrafluoroethylene diffuse reflectance standard in any direction. A view-angle independent black structural colour in snakes is reported here for the first time.
Transport stability of pesticides and PAHs sequestered in polyethylene passive sampling devices.
Donald, Carey E; Elie, Marc R; Smith, Brian W; Hoffman, Peter D; Anderson, Kim A
2016-06-01
Research using low-density polyethylene (LDPE) passive samplers has steadily increased over the past two decades. However, such research efforts remain hampered because of strict guidelines, requiring that these samplers be quickly transported in airtight metal or glass containers or foil wrapped on ice. We investigate the transport stability of model pesticides and polycyclic aromatic hydrocarbons (PAHs) with varying physicochemical properties using polytetrafluoroethylene (PTFE) bags instead. Transport scenarios were simulated with transport times up to 14 days with temperatures ranging between -20 and 35 °C. Our findings show that concentrations of all model compounds examined were stable for all transport conditions tested, with mean recoveries ranging from 88 to 113 %. Furthermore, PTFE bags proved beneficial as reusable, lightweight, low-volume, low-cost alternatives to conventional containers. This documentation of stability will allow for more flexible transportation of LDPE passive samplers in an expanding range of research applications while maintaining experimental rigor.
Transport stability of pesticides and PAHs sequestered in polyethylene passive sampling devices
Donald, Carey E.; Elie, Marc R.; Smith, Brian W.; Hoffman, Peter D.; Anderson, Kim A.
2016-01-01
Research using low-density polyethylene (LDPE) passive samplers has steadily increased over the past two decades. However such research efforts remain hampered because of strict guidelines, requiring that these samplers be quickly transported in airtight metal or glass containers, or foil-wrapped on ice. We investigate the transport stability of model pesticides and polycyclic aromatic hydrocarbons (PAHs) with varying physicochemical properties using polytetrafluoroethylene (PTFE) bags instead. Transport scenarios were simulated with transport times up to 14 days with temperatures ranging between -20 and 35 degrees Celsius. Our findings show that concentrations of all model compounds examined were stable for all transport conditions tested, with mean recoveries ranging from 88% to 113%. Furthermore, PTFE bags proved beneficial as reusable, lightweight, low-volume, low-cost alternatives to conventional containers. This documentation of stability will allow for more flexible transportation of LDPE passive samplers in an expanding range of research applications while maintaining experimental rigor. PMID:26983811
Hunt, Adam; Waldin, Owen; Slim, Hani; Brar, Ranjeet
2016-06-06
This is a unique case report describing complex limb salvage in a patient who experienced acute limb ischaemia due to a complication of intra-aortic balloon pump (IABP) counterpulsation. This case focuses on a patient who had an IABP counterpulsation device inserted following myocardial infarction, requiring urgent coronary artery bypass grafting for acute coronary syndrome. Postoperatively, the IABP could not be removed, with consequent iliac thrombosis and acute limb ischaemia. Emergency femoral-to-femoral crossover bypass was performed using a polytetrafluoroethylene graft. A portion of the IABP balloon tip was entrapped and retained, however, and became the focus of delayed septicaemia, resulting in graft infection and wound breakdown 6 weeks later. Explantation of the residual balloon tip, ligation of the right external iliac artery and redo femoral-femoral crossover using the great saphenous vein were successfully performed. 2016 BMJ Publishing Group Ltd.
Müller, Christine; Lüders, Anne; Hoth-Hannig, Wiebke; Hannig, Matthias; Ziegler, Christiane
2010-03-16
The adsorption of bovine serum albumin (BSA) on surfaces of dental enamel and of dental materials was investigated by scanning force spectroscopy. This method provides adhesion forces which can be measured as a function of contact time between protein and surface, pH, wettability, and isoelectric point of the surface. Whereas the chosen ceramic and composite materials resemble very well the adhesion on natural enamel, a much stronger adhesion was found for the more hydrophobic surfaces, that is, gold, titanium, poly(methyl methacrylate) (PMMA), and poly(tetrafluoroethylene) (PTFE). On hydrophilic surfaces, adhesion is mainly influenced by the electrostatic forces between protein and surface. However, the conformational change of BSA at pH values above pH 8 has to be taken into account. On the very hydrophobic PTFE surface, the special interface structure between PTFE and water plays an important role which governs BSA adhesion.
Thermal Consolidation of Dredge Sand for Artificial Reef Formations
NASA Astrophysics Data System (ADS)
Trevino, Alexandro
Coral Reef ecosystems have degraded over years due to a variety of environmental issues such as ocean acidification. The continuous stress has detrimental effects on coral reef ecosystems that can possibly lead to the loss of the ecosystem. Our research aims to construct a prototype of an artificial reef by consolidating dredge sand from the ship channels of South Texas. Consolidation is achieved through an aluminum polytetrafluoroethylene self-propagating high temperature process that yields a solid formation to mimic the physical properties of coral reef structures. Using thermodynamic calculations, the variation of initial components was determined that reached an adiabatic temperature with a maximum peak of 2000 K. The self-sustaining reaction front was obtained to rigidly consolidate the dredge sand only at composition concentrations exceeding a critical value of 24 wt.% Al, and 3 wt.% PTFE. The combustion synthesis produced a consolidated formation with a hardened and porous structure.
Utilizing the Foreign Body Response to Grow Tissue Engineered Blood Vessels in Vivo.
Geelhoed, Wouter J; Moroni, Lorenzo; Rotmans, Joris I
2017-04-01
It is well known that the number of patients requiring a vascular grafts for use as vessel replacement in cardiovascular diseases, or as vascular access site for hemodialysis is ever increasing. The development of tissue engineered blood vessels (TEBV's) is a promising method to meet this increasing demand vascular grafts, without having to rely on poorly performing synthetic options such as polytetrafluoroethylene (PTFE) or Dacron. The generation of in vivo TEBV's involves utilizing the host reaction to an implanted biomaterial for the generation of completely autologous tissues. Essentially this approach to the development of TEBV's makes use of the foreign body response to biomaterials for the construction of the entire vascular replacement tissue within the patient's own body. In this review we will discuss the method of developing in vivo TEBV's, and debate the approaches of several research groups that have implemented this method.
Physics, chemistry and pulmonary sequelae of thermodegradation events in long-mission space flight
NASA Technical Reports Server (NTRS)
Todd, Paul; Sklar, Michael; Ramirez, W. Fred; Smith, Gerald J.; Morgenthaler, George W.; Oberdoerster, Guenter
1993-01-01
An event in which electronic insulation consisting of polytetrafluoroethylene undergoes thermodegradation on the Space Station Freedom is considered experimentally and theoretically from the initial chemistry and convective transport through pulmonary deposition in humans. The low-gravity enviroment impacts various stages of event simulation. Vapor-phase and particulate thermodegradation products were considered as potential spacecraft contaminants. A potential pathway for the production of ultrafine particles was identified. Different approaches to the simulation and prediction of contaminant transport were studied and used to predict the distribution of generic vapor-phase products in a Space Station model. A lung transport model was used to assess the pulmonary distribution of inhaled particles, and, finally, the impact of adaptation to low gravity on the human response to this inhalation risk was explored on the basis of known physiological modifications of the immune, endocrine, musculoskeletal and pulmonary systems that accompany space flight.
Investigating Delamination Migration in Composite Tape Laminates
NASA Technical Reports Server (NTRS)
Ratcliffe, James G.; DeCarvalho, Nelson V.
2014-01-01
A modification to a recently developed test specimen designed to investigate migration of a delamination between neighboring ply interfaces in tape laminates is presented. The specimen is a cross-ply laminated beam consisting of 40 plies with a polytetrafluoroethylene insert spanning part way along its length. The insert is located between a lower 0-degree ply (specimen length direction) and a stack of four 90-degree plies (specimen width direction). The modification involved a stacking sequence that promotes stable delamination growth prior to migration, and included a relocation of the insert from the specimen midplane to the interface between plies 14 and 15. Specimens were clamped at both ends onto a rigid baseplate and loaded on their upper surface via a piano hinge assembly, resulting in a predominantly flexural loading condition. Tests were conducted with the load-application point positioned at various locations along a specimen's span. This position affected the sequence of damage events during a test.
Flexible high-temperature pH probe
Bielawski, John C.; Outwater, John O.; Halbfinger, George P.
2003-04-22
A flexible pH probe device is provided for use in hot water and other high temperature environments up to about 590.degree. F. The pH probe includes a flexible, inert tubular probe member, an oxygen anion conducting, solid state electrolyte plug located at the distal end of the tubular member, oxide powder disposed at the distal end of the tubular member; a metal wire extending along the tubular member and having a distal end in contact with the oxide powder so as to form therewith an internal reference electrode; and a compression fitting forming a pressure boundary seal around a portion of the tubular member remote from the distal end thereof. Preferably, the tubular member is made of polytetrafluoroethylene, and the solid state electrolyte plug is made of stabilized zirconia. The flexibility of the probe member enables placement of the electrode into the area of interest, including around corners, into confined areas and the like.