Ptachcinski, R J; Logue, L W; Burckart, G J; Venkataramanan, R
1986-01-01
The stability of cyclosporine in commonly used i.v. solutions and the percentage of the drug delivered via polyvinyl chloride administration tubing were studied. Cyclosporine injection was prepared according to the manufacturer's instructions and diluted with 5% dextrose injection (D5W) or with 0.9% sodium chloride injection (NS). Admixtures containing cyclosporine 2 mg/mL were prepared in polyvinyl chloride minibags (five for each solution) and in glass containers (three for each solution). The sample obtained at time zero from a glass container protected from light was the control. Additional samples were prepared in minibags and run through 70-inch polyvinyl chloride administration sets. An HPLC assay for cyclosporine was used. Exposure to room light did not significantly affect cyclosporine concentrations. More than 90% of the initial drug concentration remained after 24 hours under all storage conditions, but less than 95% remained after 6 hours in samples diluted with NS and stored in plastic. At times up to 60 minutes, cyclosporine concentrations were significantly different in solutions infused from the minibags through polyvinyl chloride tubing from those in control solutions. Under these conditions, cyclosporine is stable in D5W in glass containers or polyvinyl chloride minibags for 24 hours and in NS for 6 hours (polyvinyl chloride) to 12 hours (glass). However, because of the potential for leaching of plasticizers, cyclosporine admixtures should be stored in glass or used within six hours if stored in polyvinyl chloride minibags. Approximately 10% of the initial drug concentration is lost to 70-inch length polyvinyl chloride infusion tubing.
Shaalan, Naser; Laftah, Nawres; El-Hiti, Gamal A; Alotaibi, Mohammad Hayal; Muslih, Raad; Ahmed, Dina S; Yousif, Emad
2018-04-15
Five Schiff bases containing a thiadiazole moiety have been used as poly(vinyl chloride) photostabilizers at low concentrations. The efficiency of Schiff bases as photostabilizers was investigated using various techniques, for example, the changes in poly(vinyl chloride) infrared spectra, molecular weight, chain scission quantum yield, and surface morphology were monitored upon irradiation with an ultraviolet light. Evidently, all the additives used inhibited poly(vinyl chloride) photodegradation at a significant level. The most efficient Schiff base exhibited a high level of aromaticity and contained a hydroxyl group. It seems possible that such photostabilization could be due to the direct absorption of ultraviolet radiation by the additives. In addition, Schiff bases could act as radical scavengers and proton transfer facilitators to stabilize the polymeric materials.
Stability of Alprostadil in 0.9% Sodium Chloride Stored in Polyvinyl Chloride Containers.
McCluskey, Susan V; Kirkham, Kylian; Munson, Jessica M
2017-01-01
The stability of alprostadil diluted in 0.9% sodium chloride stored in polyvinyl chloride (VIAFLEX) containers at refrigerated temperature, protected from light, is reported. Five solutions of alprostadil 11 mcg/mL were prepared in 250 mL 0.9% sodium chloride polyvinyl chloride (PL146) containers. The final concentration of alcohol was 2%. Samples were stored under refrigeration (2°C to 8°C) with protection from light. Two containers were submitted for potency testing and analyzed in duplicate with the stability-indicating high-performance liquid chromatography assay at specific time points over 14 days. Three containers were submitted for pH and visual testing at specific time points over 14 days. Stability was defined as retention of 90% to 110% of initial alprostadil concentration, with maintenance of the original clear, colorless, and visually particulate-free solution. Study results reported retention of 90% to 110% initial alprostadil concentration at all time points through day 10. One sample exceeded 110% potency at day 14. pH values did not change appreciably over the 14 days. There were no color changes or particle formation detected in the solutions over the study period. This study concluded that during refrigerated, light-protected storage in polyvinyl chloride (VIAFLEX) containers, a commercial alcohol-containing alprostadil formulation diluted to 11 mcg/mL with 0.9% sodium chloride 250 mL was stable for 10 days. Copyright© by International Journal of Pharmaceutical Compounding, Inc.
NASA Astrophysics Data System (ADS)
Kryazhev, Yu. G.; Vorob'ev, M. S.; Koval', N. N.; Trenikhin, M. V.; Solodovnichenko, V. S.; Sulakshin, S. A.; Likholobov, V. A.
2016-10-01
This work shows the possibility in principle of forming hydrocarbon structures in polyvinyl chloride films free of admixtures and polyvinyl chloride films modified with 5-mass % ferrocene via a radiation chemical transformation in the atmosphere with the use of an electron accelerator with a plasma cathode operating in the pulsed-periodic mode maximal electron energy no higher than 160 keV, pulse length of 40 μs, and current density of 5 mA/cm2. According to the results of semiquantitative X-ray microanalysis, an irradiated polyvinyl chloride film free of admixtures contains 92 of carbon, 6 of oxygen, and 2 mass % of chlorine; the irradiated polyvinyl chloride is an amorphous carbon material. A possible mechanism of the phenomenon is discussed.
Jenke, Dennis; Couch, Tom; Gillum, Amy
2010-01-01
Material/water equilibrium binding constants (E(b)) were determined for 11 organic solutes and 2 plastic materials commonly used in pharmaceutical product containers (plasticized polyvinyl chloride and polyolefin). In general, solute binding by the plasticized polyvinyl chloride material was greater, by nearly an order of magnitude, than the binding by the polyolefin (on an equal weight basis). The utilization of the binding constants to facilitate container compatibility assessments (e.g., drug loss by container binding) for drug-containing products is discussed.
Abdul-Majid, S; Othman, F
1994-03-01
Polyethylene and polyvinyl chloride pellets were introduced into concrete to improve its neutron attenuation characteristics while several types of heavy coarse aggregates were used to improve its gamma ray attenuation properties. Neutron and gamma ray attenuation were studied in concrete samples containing coarse aggregates of barite, pyrite, basalt, hematite, and marble as well as polyethylene and polyvinyl chloride pellets in narrow-beam geometry. The highest neutron attenuation was shown by polyethylene mortar, followed by polyvinyl chloride mortar; barite and pyrite concrete showed higher gamma ray attenuation than ordinary concrete. Broad-beam and continuous (infinite) medium geometries were used to study the neutron attenuation of samples containing polymers at different concentrations with and without heavy aggregates, the fitting equations were established, and from these the neutron removal coefficients were deduced. In a radiation field of neutrons and gamma rays, the appropriate concentration of polymer and heavy aggregate can be selected to give the optimum total dose attenuation depending on the relative intensities of each type of radiation. This would give much better design flexibility over ordinary concrete. The compressive strength tests performed on mortar and concrete samples showed that their value, in general, decreases as polymer concentration increases and that the polyvinyl chloride mortar showed higher values than the polyethylene mortar. For general construction purposes, the compression strength was considered acceptable in these samples.
Leaching of diethylhexyl phthalate from polyvinyl chloride bags into intravenous etoposide solution.
Demoré, B; Vigneron, J; Perrin, A; Hoffman, M A; Hoffman, M
2002-04-01
To compare the release of diethylhexyl phthalate (DEHP) from polyvinyl chloride (PVC) bags from four different manufacturers into intravenous etoposide solutions. Etoposide solutions, 0.4 mg/mL, containing the vehicle polysorbate 80 were prepared in 5% dextrose or 0.9% sodium chloride injection PVC bags and stored at room temperature for 24 h. DEHP content was analysed by high-performance liquid chromatography. Substantial amounts of DEHP (up to 20 microg/mL at room temperature) leached into the etoposide solutions. However, no significant differences were found in the amounts of DEHP leached into the etoposide infusion solutions prepared using either 5% dextrose or 0.9% sodium chloride injection and stored in the four different containers. To minimize patient exposure o DEHP, etoposide solutions should ideally be stored in a glass or polyolefin container.
Denson, D D; Crews, J C; Grummich, K W; Stirm, E J; Sue, C A
1991-03-01
The stability of methadone hydrochloride in 0.9% sodium chloride injection in flexible polyvinyl chloride containers was studied. Commercially available methadone hydrochloride 20 mg/mL and 25-mL single-dose bags of 0.9% sodium chloride injection were used. Six samples each were prepared at methadone hydrochloride concentrations of 1, 2, and 5 mg/mL. The solutions were stored at room temperature and were not protected from light. Immediately after preparation and after two, three, and four weeks of storage, each of the 18 samples was divided into three aliquots, each of which was analyzed in duplicate for methadone hydrochloride concentration by gas chromatography. There was less than 10% change in methadone hydrochloride concentration in any sample throughout the four-week study period. Methadone hydrochloride at concentrations of 1, 2, and 5 mg/mL prepared in commercially available flexible polyvinyl chloride containers of 0.9% sodium chloride injection and stored at room temperature without deliberate protection from light is stable for at least four weeks.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-07-19
... National Emission Standards for Hazardous Air Pollutants for Polyvinyl Chloride and Copolymers Production... Polyvinyl Chloride and Copolymers Production is being extended for 14 days. DATES: Comments. The public... for the May 20, 2011, Proposed Polyvinyl Chloride and Copolymers Production Rule, the EPA is extending...
40 CFR 61.64 - Emission standard for polyvinyl chloride plants.
Code of Federal Regulations, 2010 CFR
2010-07-01
... chloride plants. 61.64 Section 61.64 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED... Standard for Vinyl Chloride § 61.64 Emission standard for polyvinyl chloride plants. An owner or operator of a polyvinyl chloride plant shall comply with the requirements of this section and § 61.65. (a...
Sequential pyrolysis of plastic to recover polystyrene HCL and terephthalic acid
Evans, Robert J.; Chum, Helena L.
1995-01-01
A process of pyrolyzing plastic waste feed streams containing polyvinyl chloride, polyethylene terephthalate, polystyrene and polyethylene to recover polystyrene HCl and terephthalic acid comprising: heating the plastic waste feed stream to a first temperature; adding an acid or base catalyst on an oxide or carbonate support; heating the plastic waste feed stream to pyrolyze polyethylene terephthalate and polyvinyl chloride; separating terephthalic acid or HCl; heating to a second temperature to pyrolyze polystyrene; separating styrene; heating the waste feed stream to a third temperature to pyrolyze polyethylene; and separating hydrocarbons.
Sequential pyrolysis of plastic to recover polystyrene, HCl and terephthalic acid
Evans, R.J.; Chum, H.L.
1995-11-07
A process is described for pyrolyzing plastic waste feed streams containing polyvinyl chloride, polyethylene terephthalate, polystyrene and polyethylene to recover polystyrene, HCl and terephthalic acid comprising: heating the plastic waste feed stream to a first temperature; adding an acid or base catalyst on an oxide or carbonate support; heating the plastic waste feed stream to pyrolyze polyethylene terephthalate and polyvinyl chloride; separating terephthalic acid or HCl; heating to a second temperature to pyrolyze polystyrene; separating styrene; heating the waste feed stream to a third temperature to pyrolyze polyethylene; and separating hydrocarbons. 83 figs.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-05-26
... National Emission Standards for Hazardous Air Pollutants for Polyvinyl Chloride and Copolymers Production... Standards for Hazardous Air Pollutants for Polyvinyl Chloride and Copolymers Production. The EPA is... present oral testimony at the public hearing, please contact Ms. Teresa Clemons, U.S. Environmental...
Preparation and characterization of silver chloride nanoparticles as an antibacterial agent
NASA Astrophysics Data System (ADS)
Duong Trinh, Ngoc; Thanh Binh Nguyen, Thi; Hai Nguyen, Thanh
2015-12-01
Silver chloride nanoparticles were prepared by the precipitation reaction between silver nitrate and sodium chloride in an aqueous solution containing poly(vinyl alcohol) as a stabilizing agent. Different characteristics of the nanoparticles in suspension and in lyophilized powder such as size, morphology, chemical nature, interaction with stabilizing agent and photo-stability were investigated. Biological tests showed that the obtained silver chloride nanoparticles displayed antibacterial activities against Escherichia coli and Staphylococcus aureus.
Hybrid blends of poly(amidoamine) PAMAM dendrimers with two linear high polymers, poly(vinyl chloride), PVC, and poly(vinyl acetate), PVAc, are reported. The interaction between the blend components was studied using dynamic mechanical analysis, xenon nuclear magnetic resonacne ...
NASA Astrophysics Data System (ADS)
Riyanto; Prawidha, A. D.
2018-01-01
Electrochemical degradation of methylene blue using Carbon-Chitosan-Polyvinyl Chloride (CC-PVC) electrode in sodium chloride have been done. The aim of this work was to degradation of methylene blue using Carbon-Chitosan-Polyvinyl Chloride (CC-PVC). Carbon chitosan composite electrode was preparing by Carbon and Chitosan powder and PVC in 4 mL tetrahydrofuran (THF) solvent and swirled flatly to homogeneous followed by drying in an oven at 100 °C for 3 h. The mixture was placed in stainless steel mould and pressed at 10 ton/cm2. Sodium chloride was used electrolyte solution. The effects of the current and electrolysis time were investigated using spectrophotometer UV-Visible. The experimental results showed that the carbon-chitosan composite electrode have higher effect in the electrochemical degradation of methylene blue in sodium chloride. Based on UV-visible spectra analysis shows current and electrolysis time has high effect to degradation of methylene blue in sodium chloride. Chitosan and polyvinyl chloride can strengthen the bond between the carbons so that the material has the high stability and conductivity. As conclusions is Carbon-Chitosan-Polyvinyl Chloride (CC-PVC) electrode have a high electrochemical activity for degradation of methylene blue in sodium chloride.
Hossain, Mirza Akram; Friciu, Mihaela; Aubin, Sebastien; Leclair, Grégoire
2014-04-15
The stability of penicillin G sodium solutions stored in polyvinyl chloride (PVC) bags or elastomeric pump containers was studied. Test samples were prepared by diluting powdered penicillin G sodium (10 million units/10-mL vial) to solutions of 2,500 or 50,000 units/mL with 0.9% sodium chloride injection or 5% dextrose injection. The preparations were transferred to 250-mL PVC bags and elastomeric pump containers. All samples were prepared in triplicate and stored at 5°C. Chemical stability was measured by a stability-indicating high-performance liquid chromatographic (HPLC) assay and by pH evaluation. Particulate matter was evaluated according to compendial standards using a light-obscuration particle count test. Preparations were visually examined throughout the study. After 21 days of storage, all test samples remained chemically stable, with an HPLC assay recovery value of more than 90% of the initial value. After 28 days, all samples prepared with either diluent and stored in PVC bags, as well as the samples diluted to 2,500 units/mL with sodium chloride injection and stored in elastomeric pump containers, did not meet the recovery acceptance limit. For all test samples, the mean pH consistently decreased during storage, from about 6.4 to about 5.5. Particle counts remained acceptable throughout the study, and no change in appearance was observed. Penicillin G for injection (2,500 and 50,000 units/mL) diluted in 0.9% sodium chloride injection or 5% dextrose injection and stored at 5°C in PVC containers or elastomeric pump containers was physically and chemically stable for a period of at least 21 days.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 8 2010-07-01 2010-07-01 false Emission standard for ethylene... AIR POLLUTANTS National Emission Standard for Vinyl Chloride § 61.65 Emission standard for ethylene dichloride, vinyl chloride and polyvinyl chloride plants. An owner or operator of an ethylene dichloride...
Liver disease among polyvinyl chloride production workers.
Creech, J L; Makk, L
1975-01-31
A protocol for systematic testing of all employees of a chemical plant is presented. This factory manufactures polyvinyl chloride compounds and resins, ABS compounds and resins, and synthetic rubber. The results were reviewed, which led to the discovery of 2 additional cases of angiosarcoma and 11 cases of portal fibrosis. Two of the 11 cases were found to have developed in employees other than polyvinyl chloride production workers.
40 CFR 63.10906 - What definitions apply to this subpart?
Code of Federal Regulations, 2010 CFR
2010-07-01
..., plenums, and fans. Chlorinated plastics means solid polymeric materials that contain chlorine in the polymer chain, such as polyvinyl chloride (PVC) and PVC copolymers. Control device means the air pollution...
40 CFR 63.10906 - What definitions apply to this subpart?
Code of Federal Regulations, 2011 CFR
2011-07-01
..., plenums, and fans. Chlorinated plastics means solid polymeric materials that contain chlorine in the polymer chain, such as polyvinyl chloride (PVC) and PVC copolymers. Control device means the air pollution...
Sañudo Hacar, P; Blanco, M G; Martínez, E; Duarte, J A; González, A; Hernández, M; Martínez, M; Cueto, E; Navajas, J A; Navarrete, M J
2012-01-01
To identify and classify disposable hospital products containing polyvinyl chloride (PVC), including the search and evaluation of cost-effective sustainable alternative products free of PVC. A descriptive observational analysis was performed, after classifying the latest research in major databases, and disposable products that could contain PVC. These were divided into 5 groups: cannulas, catheters, tubes, bags, and equipment, purchased in the period 2008-2009, differentiating between the technical and economic assessment of the materials. In the analysis of the composition of 492 articles selected, 234 (47.5%) contained PVC, and 19.4% were considered PVC-free alternatives, with only 11.3% of these being economically viable. This study highlights the advantages of the classification of PVC products, by showing that safe and efficient alternatives exist for some product lines that are consistent with patient safety and quality in the work by doctors. Copyright © 2011 SECA. Published by Elsevier Espana. All rights reserved.
Draghi, Patrícia Ferrante; Fernandes, Julio Cesar Bastos
2017-03-01
We developed a label-free potentiometric biosensor using tyrosinase extracted from Musa acuminata and immobilized by covalent bond on a surface of a solid-contact transducer. The transducer was manufactured containing two layers. The first layer contained a blend of poly(vinyl) chloride carboxylated (PVC-COOH), graphite and potassium permanganate. On this layer, we deposited a second layer containing just a mixture of poly(vinyl chloride) carboxylated and graphite. On the last layer of the transducer, we immobilized the tyrosinase enzyme by reaction with N-(3-dimethylaminopropyl)-N'-ethylcarbodiimide hydrochloride. The solid-contact potentiometric biosensor presented at low detection limit of 7.3×10 -7 M and a linear range to catechol concentration between 9.3×10 -7 M and 8.3×10 -2 M. This biosensor was applied to determine the amount of total phenols in different samples of honey and propolis. The results agreed with the Folin-Ciocalteu method. Copyright © 2016 Elsevier B.V. All rights reserved.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-03-13
... Chloride and Copolymer Production, Primary Copper Smelting, Secondary Copper Smelting, and Primary... www.regulations.gov . Title: NESHAP for Area Sources: Polyvinyl Chloride and Copolymer Production.... Respondents/Affected Entities: Owners or operators of polyvinyl chloride and copolymer, primary copper smelter...
Effect of a polyethylene-lined administration set on the availability of diazepam injection.
Hancock, B G; Black, C D
1985-02-01
Delivery of diazepam through a polyethylene-lined i.v. administration set and through a polyvinyl chloride (PVC) set was compared. Diazepam was prepared in concentrations of 50 mg/500 mL and 100 mg/500 mL in 0.9% sodium chloride injection and 5% dextrose injection in glass containers. Diazepam concentrations were measured by high-performance liquid chromatography at 0 through 5 hours in samples collected simultaneously from the glass solution containers and from the distal ends of a PVC administration set and a polyethylene-lined (non-PVC) set. Flow rates of 50 and 100 mL/hr were tested. For the non-PVC sets, diazepam concentration in the infusate was not significantly different from concentration in the glass container at any sampling time. The overall percentage of diazepam recovered was 100.7 +/- 6.8%. For the PVC sets, diazepam concentration in the infusate was less than in the container at all sampling times, and the overall percentage of diazepam recovered was 65.4 +/- 13.3% (significantly different from delivery for the non-PVC sets). Delivery through the non-PVC sets was not affected by flow rate, type of solution, or concentration of diazepam. For infusion periods of up to five hours, delivery of diazepam through polyethylene-lined i.v. administration sets was superior to delivery through polyvinyl chloride sets.
SOURCE ASSESSMENT: POLYVINYL CHLORIDE
This report summarizes data on air emissions from the polyvinyl chloride (PVC) industry. PVC is manufactured by 20 companies at 35 plants. Each plant uses one or more of four possible polymerization processes: (1) suspension polymerization, (2) emulsion polymerization, (3) bulk p...
NASA Astrophysics Data System (ADS)
Kozakevych, Roman B.; Korobeinyk, Alina V.; Bolbukh, Yulia M.; Tertykh, Valentin A.; Mikhalovska, Lyuba I.; Zienkiewicz-Strzałka, Malgorzlata; Deryło-Marczewska, Anna
2018-03-01
The silica and copper oxide nanoparticles were embedded into the polyvinyl chloride film and obtained filled composites were tested as a catalyst in the reaction of the NO release from appropriate biomolecules. Obtained materials were characterized using scanning electron, atomic-force microscopies and thermomechanical analysis. It has been shown that the introduced particles are distributed uniformly in the polymeric matrix of hybrid composite and such film produces a significant amount of NO when reacts with S-nitrosothiols. At the same time, the unfilled polyvinyl chloride film had no statistically significant catalytic activity.
Deng, Xiao Long; Takami, Tomohide; Son, Jong Wan; Kang, Eun Ji; Kawai, Tomoji; Park, Bae Ho
2013-08-01
An alternating current (AC) voltage modulation was applied to ion-selective observations with plasticized poly(vinyl chloride) membranes in glass nanopipettes. The liquid confronting the membranes in the nanopipettes, the conditioning process, and AC voltage modulation play important roles in the ion-selective detection. In the AC detection system developed by us, where distilled water was used as the liquid within the nanopipettes, potassium ions were selectively detected in the sample solution of sodium and potassium ions because sodium ions were captured at the membrane containing bis(12-crown-4) ionophores, before the saturation of the ionophores. The membrane lost the selectivity after the saturation. On using sodium chloride as the liquid within the nanopipette, the membrane selectively detected potassium and sodium ions before and after the saturation of ionophores, respectively. The ion-selective detection of our system can be explained by the ion extraction-diffusion-dissolution mechanism through the bis(12-crown-4) ionophores with AC voltage modulation.
Learn about the regulations for the Polyvinyl Chloride and Copolymers Production Production regarding the emissions of hazardous air pollutants. Find Federal Register citations, read the rule, and find the rule history here.
Suresh, Sunil S; Mohanty, Smita; Nayak, Sanjay K
2018-06-01
The current investigation deals with the recycling possibilities of poly(vinyl chloride) and poly(methyl methacrylate) in the presence of acrylonitrile butadiene rubber. Recycled blends of poly(vinyl chloride)/poly(methyl methacrylate) are successfully formed from the plastic constituents, those are recovered from waste computer products. However, lower impact performance of the blend and lower stability of the poly(vinyl chloride) phase in the recycled blend restricts its further usage in industrial purposes. Therefore, effective utilisation acrylonitrile butadiene rubber in a recycled blend was considered for improving mechanical and thermal performance. Incorporation of acrylonitrile butadiene rubber resulted in the improvement in impact performance as well as elongation-at-break of the recycled blend. The optimum impact performance was found in the blend with 9 wt% acrylonitrile butadiene rubber, which shows 363% of enhancement as compared with its parent blend. Moreover, incorporated acrylonitrile butadiene rubber also stabilises the poly(vinyl chloride) phase present in the recycled blend, similarly Fourier transform infrared spectroscopy studies indicate the interactions of various functionalities present in the recycled blend and acrylonitrile butadiene rubber. In addition to this, thermogravimetric analysis indicates the improvement in the thermal stability of the recycled blend after the addition of acrylonitrile butadiene rubber into it. The existence of partial miscibility in the recycled blend was identified using differential scanning calorimetry and scanning electron microscopy.
Plasticizers derived from cardanol: Synthesis and plasticization properties for poly(vinyl chloride)
USDA-ARS?s Scientific Manuscript database
Two natural plasticizers derived from cardanol, cardanol acetate (CA), and epoxidized cardanol acetate (ECA), were synthesized and characterized by 1H NMR and 13C NMR. The plasticizing effects of the obtained plasticizers on semi-rigid polyvinyl chloride (PVC) formulations were also investigated. Tw...
USDA-ARS?s Scientific Manuscript database
The rheological properties of aqueous solutions and films made from blends of polyvinyl alcohol (PVOH) and amylose-hexadecylammonium chloride inclusion complexes (Hex-Am) were investigated to better understand the polymer interactions and processing parameters. Aqueous solutions of Hex-Am displayed ...
21 CFR 175.270 - Poly(vinyl fluoride) resins.
Code of Federal Regulations, 2013 CFR
2013-04-01
... polymerization of vinyl fluoride. (b) The poly(vinyl fluoride) basic resins have an intrinsic viscosity of not... Dilute Solution Viscosity of Vinyl Chloride Polymers,” which is incorporated by reference. Copies may be... Solution Viscosity of Vinyl Chloride Polymers,” which is incorporated by reference; see paragraph (b) of...
21 CFR 175.270 - Poly(vinyl fluoride) resins.
Code of Federal Regulations, 2012 CFR
2012-04-01
... polymerization of vinyl fluoride. (b) The poly(vinyl fluoride) basic resins have an intrinsic viscosity of not... Dilute Solution Viscosity of Vinyl Chloride Polymers,” which is incorporated by reference. Copies may be... Solution Viscosity of Vinyl Chloride Polymers,” which is incorporated by reference; see paragraph (b) of...
Sorption of amiodarone to polyvinyl chloride infusion bags and administration sets.
Weir, S J; Myers, V A; Bengtson, K D; Ueda, C T
1985-12-01
The loss of amiodarone from i.v. admixtures to flexible polyvinyl chloride (PVC) infusion bags and i.v. administration sets was studied. Admixtures containing amiodarone hydrochloride 600 micrograms/mL and either 5% dextrose injection or 0.9% sodium chloride injection were stored at room temperature in glass bottles (both with and without contact of the drug solution with the rubber bottle closure), in flexible PVC bags, or in rigid PVC bottles. After 120 hours, the contents of each flexible PVC bag were emptied and replaced by methanol, which was allowed to remain in the bag for an additional 120 hours and was then analyzed for amiodarone content. To determine availability of amiodarone after infusion through a 1.8-m PVC i.v. administration set, solutions stored in glass containers were run through the set at 0.5 mL/min for 90 minutes. Samples of drug solutions were collected at appropriate intervals and analyzed by a stability-indicating high-performance liquid chromatography (HPLC) assay. Admixtures containing 0.9% sodium chloride injection were not stable; visual incompatibility was evident after 24 hours of storage in glass bottles, and no further testing was performed. In admixtures containing 5% dextrose injection that were stored in 50-mL flexible PVC bags, 60% of the initial amiodarone concentration remained after 120 hours; approximately half of the lost drug was recovered with the methanol. In effluent collected from the PVC administration set, 82% of the initial amiodarone concentration remained. Amiodarone concentrations did not decrease appreciably, after storage in glass or rigid PVC bottles, indicating that drug loss was probably affected by the plasticizer, di-2-ethylhexyl phthalate.(ABSTRACT TRUNCATED AT 250 WORDS)
Rizal, Datu; Tani, Shinichi; Nishiyama, Kimitoshi; Suzuki, Kazuhiko
2006-10-11
In this paper, a novel methodology in batch plant safety and reliability analysis is proposed using a dynamic simulator. A batch process involving several safety objects (e.g. sensors, controller, valves, etc.) is activated during the operational stage. The performance of the safety objects is evaluated by the dynamic simulation and a fault propagation model is generated. By using the fault propagation model, an improved fault tree analysis (FTA) method using switching signal mode (SSM) is developed for estimating the probability of failures. The timely dependent failures can be considered as unavailability of safety objects that can cause the accidents in a plant. Finally, the rank of safety object is formulated as performance index (PI) and can be estimated using the importance measures. PI shows the prioritization of safety objects that should be investigated for safety improvement program in the plants. The output of this method can be used for optimal policy in safety object improvement and maintenance. The dynamic simulator was constructed using Visual Modeler (VM, the plant simulator, developed by Omega Simulation Corp., Japan). A case study is focused on the loss of containment (LOC) incident at polyvinyl chloride (PVC) batch process which is consumed the hazardous material, vinyl chloride monomer (VCM).
Role of metal oxides in the thermal degradation of poly(vinyl chloride)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gupta, M.C.; Viswanath, S.G.
Thermal degradation of poly(vinyl chloride) has been studied in the presence of metal oxides by a thermogravimetric method. It follows a two-step mechanism. In the first step chlorine free radical is formed as in the case of pure PVC, and in the second step chlorine free radical replaces oxygen from metal oxide to form metal chloride and oxygen free radical. Subsequently, the oxygen free radical abstracts hydrogen from PVC. Formation of metal chloride is the rate-controlling step. The metal chlorides formed during the thermal degradation either volatilize or decompose simultaneously to lower metallic chlorides depending on the boiling point ormore » the volatilization temperature.« less
Myers, Alan L; Zhang, Yang-Ping; Kawedia, Jitesh D; Trinh, Van A; Tran, Huyentran; Smith, Judith A; Kramer, Mark A
2016-02-01
Carboplatin is a platinum-containing compound with efficacy against various malignancies. The physico-chemical stability of carboplatin in dextrose 5% water (D5W) has been thoroughly studied; however, there is a paucity of stability data in clinically relevant 0.9% sodium chloride infusion solutions. The manufacturer's limited stability data in sodium chloride solutions hampers the flexibility of carboplatin usage in oncology patients. Hence, the purpose of this study is to determine the physical and chemical stability of carboplatin-sodium chloride intravenous solutions under different storage conditions. The physico-chemical stability of 0.5 mg/mL, 2.0 mg/mL, and 4.0 mg/mL carboplatin-sodium chloride solutions prepared in polyvinyl chloride bags was determined following storage at room temperature under ambient fluorescent light and under refrigeration in the dark. Concentrations of carboplatin were measured at predetermined time points up to seven days using a stability-indicating high-performance liquid chromatography method. All tested solutions were found physically stable for at least seven days. The greatest chemical stability was observed under refrigerated storage conditions. At 4℃, all tested solutions were found chemically stable for at least seven days, with nominal losses of ≤6%. Following storage at room temperature exposed to normal fluorescent light, the chemical stability of 0.5 mg/mL, 2.0 mg/mL, and 4.0 mg/mL solutions was three days, five days, and seven days, respectively. The extended physico-chemical stability of carboplatin prepared in sodium chloride reported herein permits advance preparation of these admixtures, facilitating pharmacy utility and operations. Since no antibacterial preservative is contained within these carboplatin solutions, we recommend storage, when prepared under specified aseptic conditions, no greater than 24 h at room temperature or three days under refrigeration. © The Author(s) 2014.
Military Handbook: General Guidelines for Electronic Equipment
1995-04-28
Epoxy- resin PoLyricinoteates Lubricants Polyvinyl chloride Metamine- formaldehyde Polyvinyl chloride-acetate Organic potysuLphides Potyvinyt fluoride...Phenol- formaldehyde Rubbers, natural and synthetic Polydichlorostyrene Urea - formaldehyde 1/Literature shows that under certain conditions polyamides may...Electrical, Synthetic- Resin Composition, Non-Rigid MIL-T-713 Twine, Fibrous: Impregnated , Lacing and Tying MIL-I-3158 Insulation Tape, Electrical Glass
USDA-ARS?s Scientific Manuscript database
In this work, for the first time, a castor oil derived diglycidyl ester plasticizer (C26-DGE) was prepared and incorporated into poly(vinyl chloride) (PVC). The chemical structure of the product was characterized by Fourier transform infrared spectroscopy (FT-IR), proton nuclear magnetic resonance (...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-05-20
... submitting comments. E-mail: a-and-r[email protected] . Attn: Docket ID No. EPA- HQ-OAR-2002-0037. Fax: (202...://www.regulations.gov Web site is an ``anonymous access'' system, which means EPA will not know your... absolute PVC--polyvinyl chloride and copolymers PVCPU--PVC production process unit RFA--Regulatory...
Antimicrobial Effect of An Essential Oil Blend on Surface-attached Salmonella on Polyvinyl Chloride
USDA-ARS?s Scientific Manuscript database
The majority of drinking water lines for broilers are made of polyvinyl chloride (PVC) and surface attachment of Salmonella on the inner surface of water lines can be the initial stage of biofilm development. These biofilms can be the source of Salmonella infection in water lines and are known to re...
USDA-ARS?s Scientific Manuscript database
A novel plasticizer derived from cardanol, epoxied cardanol glycidyl ether (ECGE), was synthesized and characterized by 1H-NMR and 13C-NMR. Effects of the ECGE combined with dioctyl phthalate (DOP), a commercial plasticizer, in soft poly(vinyl chloride) (PVC) films were studied. Dynamic mechanical a...
Modeling polyvinyl chloride Plasma Modification by Neural Networks
NASA Astrophysics Data System (ADS)
Wang, Changquan
2018-03-01
Neural networks model were constructed to analyze the connection between dielectric barrier discharge parameters and surface properties of material. The experiment data were generated from polyvinyl chloride plasma modification by using uniform design. Discharge voltage, discharge gas gap and treatment time were as neural network input layer parameters. The measured values of contact angle were as the output layer parameters. A nonlinear mathematical model of the surface modification for polyvinyl chloride was developed based upon the neural networks. The optimum model parameters were obtained by the simulation evaluation and error analysis. The results of the optimal model show that the predicted value is very close to the actual test value. The prediction model obtained here are useful for discharge plasma surface modification analysis.
Compatibility and activity of enoxaparin sodium in 0.9% sodium chloride injection for 48 hours.
Mewborn, A L; Kessler, J M; Joyner, K A
1996-01-15
The stability of enoxaparin sodium in 0.9% sodium chloride injection in polyvinyl chloride (PVC) containers was studied. Triplicate solutions of 120 mg (1.2 mL) of enoxaparin (as the sodium salt) and 98.8 mL of 0.9% sodium chloride injection were prepared in 250-mL PVC containers and stored at room temperature (20-22 degrees C). Samples were taken immediately after preparation and at 0.25, 0.5, 0.75, 1, 4, 12, 16, 24, and 48 hours. Inspections for color change and precipitation were performed with a clarity inspection station and a magnifying glass. Samples of the three admixtures were evaluated in duplicate for pharmacologic activity by an automated coagulation heparin assay. Throughout the 48-hour study period, the enoxaparin admixtures were free of color change, evolution of gas, and precipitates. The pharmacologic activity of enoxaparin in the PVC containers remained > 94% of the initial measured activity for 48 hours. Enoxaparin 1.2 mg/mL (as the sodium salt) in 0.9% sodium chloride injection in PVC containers was stable for up to 48 hours at 20-22 degrees C.
Hansen Solubility Parameters for Octahedral Oligomeric Silsesquioxanes
2012-08-28
Chujo, Y. Synthesis of organic-inorganic polymer hybrids from poly(vinyl chloride ) and polyhedral oligomeric silsesquioxane via CH/pi interaction...referred to as octa(phenethyl), POSS and either polystyrene22 or polyvinyl chloride .23 However, in many cases, the reported solubility of POSS...Acetonitrile 1.82 Fail E- 1.85 Fail E- 2.40 Fail E- Acetone 0.33 Pass E+ 0.58 Pass E+ 1.27 Pass U+ Allyl Chloride 1.64 Fail E- 1.83 Fail E- 1.42 Fail E
NASA Astrophysics Data System (ADS)
John, Beena Mary; Ushamani, M.; Sreekumar, K.; Joseph, Rani; Sudha Kartha, C.
2007-01-01
The diffraction efficiency, sensitivity, and storage life of methylene blue-sensitized poly(vinyl chloride) film was improved by the addition of an electron donor in the matrix. The addition of pyridine enhanced the diffraction efficiency by two times, and storage life of the gratings was increased to 2-3 days.
Philippart, François; Gaudry, Stéphane; Quinquis, Laurent; Lau, Nicolas; Ouanes, Islem; Touati, Samia; Nguyen, Jean Claude; Branger, Catherine; Faibis, Frédéric; Mastouri, Maha; Forceville, Xavier; Abroug, Fekri; Ricard, Jean Damien; Grabar, Sophie; Misset, Benoît
2015-03-15
The occurrence of ventilator-associated pneumonia (VAP) is linked to the aspiration of contaminated pharyngeal secretions around the endotracheal tube. Tubes with cuffs made of polyurethane rather than polyvinyl chloride or with a conical rather than a cylindrical shape increase tracheal sealing. To test whether using polyurethane and/or conical cuffs reduces tracheal colonization and VAP in patients with acute respiratory failure. We conducted a multicenter, prospective, open-label, randomized study in four parallel groups in four intensive care units between 2010 and 2012. A cohort of 621 patients with expected ventilation longer than 2 days was included at intubation with a cuff composed of cylindrical polyvinyl chloride (n = 148), cylindrical polyurethane (n = 143), conical polyvinyl chloride (n = 150), or conical polyurethane (n = 162). We used Kaplan-Meier estimates and log-rank tests to compare times to events. After excluding 17 patients who secondarily refused participation or had met an exclusion criterion, 604 were included in the intention-to-treat analysis. Cumulative tracheal colonization greater than 10(3) cfu/ml at Day 2 was as follows (median [interquartile range]): cylindrical polyvinyl chloride, 0.66 (0.58-0.74); cylindrical polyurethane, 0.61 (0.53-0.70); conical polyvinyl chloride, 0.67 (0.60-0.76); and conical polyurethane, 0.62 (0.55-0.70) (P = 0.55). VAP developed in 77 patients (14.4%), and postextubational stridor developed in 28 patients (6.4%) (P = 0.20 and 0.28 between groups, respectively). Among patients requiring mechanical ventilation, polyurethane and/or conically shaped cuffs were not superior to conventional cuffs in preventing tracheal colonization and VAP. Clinical trial registered with clinicaltrials.gov (NCT01114022).
Controlled release chamber for dispensing aromatic substances.
Cilek, J E; Hallmon, C F
2008-12-01
A novel device for the containment and precise release of aromatic substances is described. The device consists of a threaded-tubular polyvinyl chloride chamber (and screw-top cap) with ports for introduction and release of gaseous compounds. This chamber is inexpensive, easy to assemble, and useful for evaluating the combined release of carbon dioxide and aromatic hygroscopic substances as mosquito attractants in field studies.
Experimental Polyvinyl Chloride (PVC) Roofing: Field Test Results.
1987-02-01
construction. These were the single-ply membranes of the ethylene-propylene-diene monomer ( EPDM ) and polyvinyl chloride (PVC) types, and the sprayed-in-place...polyurethane foam (PUF) with an elastomeric coating. EPDM and PUF roofs were constructed in 19802 and the PVC roofs were completed during summer 1983...faced isocyanu- rate foam board in two layers . Roofing systems were installed loose-laid and ballasted. Specific membrane materials were Plymouth
TOXICOLOGY OF MONO- AND DI-ALKYLTIN CHLORIDES
Mono- and di-alkyltin chlorides are reactive compounds used in the production of stabilizers for polyvinyl chloride (PVC) plastics, primarily used for water distribution pipes. Health effects data were compiled or developed by the manufacturers for the EPA's HPV Challenge progra...
TOXICOLOGY OF MONO- AND DI-ALKYLTIN CHLORIDES.
Mono- and di-alkyltin chlorides are reactive compounds used in the production of stabilizers for polyvinyl chloride (PVC) plastics, primarily used for water distribution pipes. Health effects data were compiled or developed by the manufacturers for the EPA's HPV Challenge progra...
Wu, Chunfei; Nahil, Mohamad A; Miskolczi, Norbert; Huang, Jun; Williams, Paul T
2014-01-01
Producing both hydrogen and high-value carbon nanotubes (CNTs) derived from waste plastics is reported here using a pyrolysis-reforming technology comprising a two-stage reaction system, in the presence of steam and a Ni-Mn-Al catalyst. The waste plastics consisted of plastics from a motor oil container (MOC), commercial waste high density polyethylene (HDPE) and regranulated HDPE waste containing polyvinyl chloride (PVC). The results show that hydrogen can be produced from the pyrolysis-reforming process, but also carbon nanotubes are formed on the catalyst. However, the content of 0.3 wt.% polyvinyl chloride in the waste HDPE (HDPE/PVC) has been shown to poison the catalyst and significantly reduce the quantity and purity of CNTs. The presence of sulfur has shown less influence on the production of CNTs in terms of quantity and CNT morphologies. Around 94.4 mmol H2 g(-1) plastic was obtained for the pyrolysis-reforming of HDPE waste in the presence of the Ni-Mn-Al catalyst and steam at a reforming temperature of 800 °C. The addition of steam in the process results in an increase of hydrogen production and reduction of carbon yield; in addition, the defects of CNTs, for example, edge dislocations were found to be increased with the introduction of steam (from Raman analysis).
NASA Astrophysics Data System (ADS)
İmren, Dilek; Boztuğ, Ali; Yılmaz, Ersen; Zengin, H. Bayram
2008-11-01
In this study, a blend of poly(vinyl chloride) (PVC)/ethylene-co-vinyl acetate (EVA) was compatibilized by terpolymer of maleic anhydride-styrene-vinyl acetate (MAStVA) used as a compatibilizer. It was prepared the blends of 50/50 PVC/EVA containing 2-10% of the terpolymer. The compatibility experiences of these blends were investigated by using viscometric method in the range of concentrations (0.5-2.0 g dL -1) where tetrahydrofuran (THF) is the solvent. The interaction parameter (Δ b) was used to study the miscibility and compatibility of polymer blend in solution, obtained from the modified Krigbaum and Wall theory. Turbidity and FTIR measurements were also used to investigate the miscibility of this pair of polymers. The values of the relative viscosities of the each polymer solution and their blends were measured by a Cannon-Fenske type viscometer. In consequence of the study, it was observed that a considerable improvement was achieved in the miscibility of PVC/EVA blends by adding among 5 and 10 wt% of compatibilizer.
New Tetra-Schiff Bases as Efficient Photostabilizers for Poly(vinyl chloride).
Ahmed, Dina S; El-Hiti, Gamal A; Hameed, Ayad S; Yousif, Emad; Ahmed, Ahmed
2017-09-09
Three new tetra-Schiff bases were synthesized and characterized to be used as photostabilizers for poly(vinyl chloride) (PVC) films. The photostability of PVC films (40 μm thickness) in the presence of Schiff bases (0.5 wt %) upon irradiation (300 h) with a UV light (λ max = 365 nm and light intensity = 6.43 × 10 -9 ein∙dm -3 ∙s -1 ) was examined using various spectroscopic measurements and surface morphology analysis. The changes in various functional groups' indices, weight and viscosity average molecular weight of PVC films were monitored against irradiation time. The additives used showed photostability for PVC films, with Schiff base 1 being the most effective additive upon irradiation, followed by 2 and 3 . The atomic force microscopy (AFM) images for the PVC surface containing Schiff base 1 after irradiation were found to be smooth, with a roughness factor ( R q) of 36.8, compared to 132.2 for the PVC (blank). Several possible mechanisms that explain PVC photostabilization upon irradiation in the presence of tetra-Schiff bases were proposed.
Stability of Metronidazole Suspensions.
Donnelly, Ronald F; Ying, James
2015-01-01
Metronidazole is an antiprotozoal agent used in the treatment of bacterial and protozoal anaerobic infections. The objectives of this study were to develop concentrated metronidazole suspensions that are inexpensive and easy to prepare and determine the stability of these suspensions after storage in amber polyvinyl chloride bottles at room temperature (23°C) and under refrigeration (5°C). Metronidazole suspensions (50 mg/mL) were prepared from powder using Ora-Blend or simple syrup as the vehicles. Samples were collected in triplicate from each container on days 0, 7, 14, 28, 56, and 93. Samples were assayed using a high-performance liquid chromatography method that had been validated as stability indicating. Color, change in physical appearance, and pH were also monitored at each time interval. There was no apparent change in color or physical appearance. The pH values changed by less than 0.20 units over the 93 days. The stability of metronidazole suspensions compounded from United States Pharmacopeia powder using Ora-Blend or simple syrup and packaged in amber polyvinyl chloride bottles was determined to be 93 days when stored at either room temperature or under refrigeration.
Sun, Yingying; Hua, Xiuyi; Ge, Rui; Guo, Aitong; Guo, Zhiyong; Dong, Deming; Sun, Wentian
2013-08-01
Centrifugal mother liquid (CML) is one of the main sources of wastewater produced during the production of polyvinyl chloride in chlor-alkali industry. CML is a typical poorly biodegradable organic wastewater, containing many kinds of refractory pollutants. Specifically, it contains dissolved refractory polymers, especially polyvinyl alcohol (PVA), which can pass though the biotreatment processes and clog the membranes used for further treatment. In this study, to ensure the CML applicable to biotreatment and membrane treatment, a novel efficient and mild technique, air-Fenton treatment, was employed as a pretreatment technique to improve biodegradability of the CML and to break down the polymers in the CML. Firstly, the technique was optimized for the CML treatment by optimizing the main parameters, including the dosage of ferrous sulfate, initial pH of the wastewater, [H2O2]/[Fe(2+)], aeration rate, reaction time, and temperature, based on removal efficiency of COD and PVA from the CML. Then, the optimized technique was tested and evaluated. The results indicated that under the optimized conditions, the air-Fenton treatment could remove 66, 98, and 55 % of the COD, PVA, and TOC, respectively, from the CML. After the treatment, biodegradability of the wastewater increased significantly (BOD/COD increased from 0.31 to 0.68), and almost all of the PVA polymers were removed or broken down. Meanwhile, concentration of the remaining iron ions, which were added during the treatment, was also quite low (only 2.9 mg/L). Furthermore, most of the suspended materials and ammonia nitrogen, and some of the phosphorus in the wastewater were removed simultaneously.
NASA Astrophysics Data System (ADS)
Junaidi, Triyana, Kuwat; Harsojo, Suharyadi, Edi
2016-04-01
We report our investigation on the effect of chloride ions oncontrolling the shapes and properties of silver nanorods(AgNRs) synthesized using a polyol method. In this study, we used polyvinyl alcohol (PVA) as a capping agent and sodium chloride (NaCl) as asalt precursor and performed at the oilbath temperature of 140 °C. The chloride ions originating from the NaCl serve to control the growth of the silver nanorods. Furthermore, the synthesized silver nanorodswere characterized using UV-VIS, XRD, SEM and TEM. The results showed that besides being able to control the growth of AgCl atoms, the chloride ions were also able to control the growth of multi-twinned-particles into the single crystalline silver nanorods by micrometer-length. At an appropriate concentration of NaCl, the diameter of silver nanorodsdecreased significantly compared to that of without chloride ion addition. This technique may be useful since a particular diameter of silver nanorods affects a particular application in the future.
Acute health effects among firefighters exposed to a polyvinyl chloride (PVC) fire
DOE Office of Scientific and Technical Information (OSTI.GOV)
Markowitz, J.S.; Gutterman, E.M.; Schwartz, S.
1989-05-01
Firefighters are frequently being called on to fight fires that are chemical in nature. In the aftermath of a chemical fire in Plainfield, New Jersey on March 20-21, 1985, the authors conducted a retrospective cohort study which surveyed 80 firefighters exposed to burning polyvinyl chloride (PVC) as well as 15 nonexposed firefighter subjects. By means of an 81-item symptom checklist, exposed firefighters reported more frequent and severe symptoms at 5-6 weeks post incident. This was true for a total symptomatology score as well as 19 individual items. Some of the items with an elevated risk were consistent with exposure tomore » hydrogen chloride, the main pyrolysis product of polyvinyl chloride. Other items with an elevated risk appeared to be related to smoke inhalation while others seemed psychosocial in nature. Analyses conducted within the exposed firefighter group showed that fighting the fire the first day, being a truckman, and residence within 1 mile (1.6 km) of the firehouse were significant risk factors for high total symptom scores. These risk factors may have been associated with level or duration of exposure to the toxic substances produced during the fire.« less
TSCA Section 21 Petition to Promulgate Regulations Governing PVCs
This petition requests EPA to promulgate regulations governing the safe treatment, storage and disposal of polyvinyl chloride (PVC), vinyl chloride and associated dialkyl- and alkylarylesters of 1,2-benzenedicarboxylic acid.
Stability of levothyroxine injection in glass, polyvinyl chloride, and polyolefin containers.
Frenette, Anne Julie; MacLean, Robert D; Williamson, David; Marsolais, Pierre; Donnelly, Ronald F
2011-09-15
The 24-hour stability of a levothyroxine solution admixed and stored in three common infusion containers and infused through polyvinyl chloride (PVC) tubing was evaluated. Levothyroxine sodium 1-μg/mL injection prepared in glass bottles and PVC and polyolefin bags were assayed using high-performance liquid chromatography at 0, 1, 3, 6, 12, and 24 hours; samples drawn directly from the containers, as well as from the distal end of attached PVC tubing, were assayed. The area under the time-versus-concentration curve (AUC) for predicted and delivered doses was calculated; analysis of variance was used for comparison of the percentages of predicted and actual AUC values. The levothyroxine concentration was stable in glass bottles and polyolefin bags through 24 hours (mean ± S.D. percentage of initial concentration remaining, 103.5% ± 2.5% and 100.0% ± 2.9%, respectively). In the PVC infusion bags, the amount of drug decreased to 90% of the initial concentration within 1 hour and then rose and remained within acceptability limits. The levothyroxine concentration of the samples infused through PVC line from glass and polyolefin containers decreased after 1 hour by about 13%; the loss of the drug from the samples infused from PVC bags was higher (18%), presumably due to additive adsorptive effects. In all samples tested, the drug concentration rebounded and remained above 90% to the end of the study. Levothyroxine sodium 1-μg/mL solution was stable for 24 hours in glass bottles and polyolefin bags but when stored in PVC bags, the concentration decreased by 10% after 1 hour.
Code of Federal Regulations, 2011 CFR
2011-07-01
... basis and analyzes the samples with gas chromatography or, if the owner or operator assumes that all... concentration of vinyl chloride in the exhaust gases does not exceed 10 ppm (average for 3-hour period), or... chloride in the exhaust gases does not exceed 10 ppm (average for 3-hour period), or equivalent as provided...
IRIS Toxicological Review of Vinyl Chloride (Final Report ...
EPA is announcing the release of the final report, Toxicological Review of Vinyl Chloride: in support of the Integrated Risk Information System (IRIS). The updated Summary for Vinyl Chloride and accompanying Quickview have also been added to the IRIS Database. Common synonyms of vinyl chloride (VC) include chloroethene, chloroethylene, ethylene monochloride, and monochloroethene. VC is a synthetic chemical used as a chemical intermediate in the polymerization of polyvinyl chloride.
Apparatus for inspecting piping
Zollingger, W. Thor; Appel, D. Keith; Park, Larry R.
1995-01-01
An inspection rabbit for inspecting piping systems having severe bends therein. The rabbit consists of a flexible, modular body containing a miniaturized eddy current inspection probe, a self-contained power supply for proper operation of the rabbit, an outer surface that allows ease of movement through piping systems and means for transmitting data generated by the inspection device. The body is preferably made of flexible polyvinyl chloride (PVC) tubing or, alternatively, silicone rubber with a shrink wrapping of polytetrafluoroethylene (TEFLON.RTM.). The body is formed to contain the power supply, preferably a plurality of batteries, and a spool of communication wire that connects to a data processing computer external to the piping system.
Brown, Suree; Yue, Yanfeng; Kuo, Li-Jung; ...
2016-03-11
The need to secure future supplies of energy attracts researchers in several countries to a vast resource of nuclear energy fuel: uranium in seawater (estimated at 4.5 billion tons in seawater). In this study, we developed effective adsorbent fibers for the recovery of uranium from seawater via atom-transfer radical polymerization (ATRP) from a poly-(vinyl chloride)-co-chlorinated poly(vinyl chloride) (PVC-co-CPVC) fiber. ATRP was employed in the surface graft polymerization of acrylonitrile (AN) and tert-butyl acrylate (tBA), precursors for uranium-interacting functional groups, from PVC-co-CPVC fiber. The [tBA]/[AN] was systematically varied to identify the optimal ratio between hydrophilic groups (from tBA) and uranyl-binding ligandsmore » (from AN). The best performing adsorbent fiber, the one with the optimal [tBA]/[AN] ratio and a high degree of grafting (1390%), demonstrated uranium adsorption capacities that are significantly greater than those of the Japan Atomic Energy Agency (JAEA) reference fiber in natural seawater tests (2.42 3.24 g/kg in 42 days of seawater exposure and 5.22 g/kg in 49 days of seawater exposure, versus 1.66 g/kg in 42 days of seawater exposure and 1.71 g/kg in 49 days of seawater exposure for JAEA). Lastly, adsorption of other metal ions from seawater and their corresponding kinetics were also studied. The grafting of alternative monomers for the recovery of uranium from seawater is now under development by this versatile technique of ATRP.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Brown, Suree; Yue, Yanfeng; Kuo, Li-Jung
The need to secure future supplies of energy attracts researchers in several countries to a vast resource of nuclear energy fuel: uranium in seawater (estimated at 4.5 billion tons in seawater). In this study, we developed effective adsorbent fibers for the recovery of uranium from seawater via atom-transfer radical polymerization (ATRP) from a poly-(vinyl chloride)-co-chlorinated poly(vinyl chloride) (PVC-co-CPVC) fiber. ATRP was employed in the surface graft polymerization of acrylonitrile (AN) and tert-butyl acrylate (tBA), precursors for uranium-interacting functional groups, from PVC-co-CPVC fiber. The [tBA]/[AN] was systematically varied to identify the optimal ratio between hydrophilic groups (from tBA) and uranyl-binding ligandsmore » (from AN). The best performing adsorbent fiber, the one with the optimal [tBA]/[AN] ratio and a high degree of grafting (1390%), demonstrated uranium adsorption capacities that are significantly greater than those of the Japan Atomic Energy Agency (JAEA) reference fiber in natural seawater tests (2.42 3.24 g/kg in 42 days of seawater exposure and 5.22 g/kg in 49 days of seawater exposure, versus 1.66 g/kg in 42 days of seawater exposure and 1.71 g/kg in 49 days of seawater exposure for JAEA). Lastly, adsorption of other metal ions from seawater and their corresponding kinetics were also studied. The grafting of alternative monomers for the recovery of uranium from seawater is now under development by this versatile technique of ATRP.« less
Mechanical degradation temperature of waste storage materials
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fink, M.C.; Meyer, M.L.
1993-05-13
Heat loading analysis of the Solid Waste Disposal Facility (SWDF) waste storage configurations show the containers may exceed 90{degrees}C without any radioactive decay heat contribution. Contamination containment is primarily controlled in TRU waste packaging by using multiple bag layers of polyvinyl chloride and polyethylene. Since literature values indicate that these thermoplastic materials can begin mechanical degradation at 66{degrees}C, there was concern that the containment layers could be breached by heating. To better define the mechanical degradation temperature limits for the materials, a series of heating tests were conducted over a fifteen and thirty minute time interval. Samples of a low-densitymore » polyethylene (LDPE) bag, a high-density polyethylene (HDPE) high efficiency particulate air filter (HEPA) container, PVC bag and sealing tape were heated in a convection oven to temperatures ranging from 90 to 185{degrees}C. The following temperature limits are recommended for each of the tested materials: (1) low-density polyethylene -- 110{degrees}C; (2) polyvinyl chloride -- 130{degrees}C; (3) high-density polyethylene -- 140{degrees}C; (4) sealing tape -- 140{degrees}C. Testing with LDPE and PVC at temperatures ranging from 110 to 130{degrees}C for 60 and 120 minutes also showed no observable differences between the samples exposed at 15 and 30 minute intervals. Although these observed temperature limits differ from the literature values, the trend of HDPE having a higher temperature than LDPE is consistent with the reference literature. Experimental observations indicate that the HDPE softens at elevated temperatures, but will retain its shape upon cooling. In SWDF storage practices, this might indicate some distortion of the waste container, but catastrophic failure of the liner due to elevated temperatures (<185{degrees}C) is not anticipated.« less
Michelot, Harmonie; Fu, Shanlin; Stuart, Barbara; Shimmon, Ronald; Raymond, Tony; Crandell, Tony; Roux, Claude
2017-04-01
In the area of clandestine laboratory investigations, plastic bags are used to collect and store evidence, such as solvents, precursors, and other compounds usually employed for the manufacturing of drugs (although liquids may be stored in glass containers within the bags first). In this study, three different types of plastic bags were provided by the NSW Police Force and investigated for their suitability for evidence collection: two different types of low-density polyethylene (LDPE) bags and one type of polyvinyl chloride (PVC) bag. Three different experiments were carried out: (1) storing relevant chemicals in the bags for up to three months; (2) exposing the bags including their content to accelerated conditions using a weatherometer, and (3) simulating an expected real case scenario. This study indicates that drugs and related chemicals stored in plastic bags may lead to a change in the composition of the chemical and an alteration or degradation of the plastic bag. All experiments led to the same conclusion: the polyvinyl chloride bags appeared to be the most affected. LDPE bags seem to be more appropriate for routine use, although it has been established they are not suitable for the collection of liquids (unless pre-packaged in, for instance, a glass container). Copyright © 2017 Elsevier B.V. All rights reserved.
40 CFR 61.64 - Emission standard for polyvinyl chloride plants.
Code of Federal Regulations, 2011 CFR
2011-07-01
...) before being opened. (d) Monomer recovery system. The concentration of vinyl chloride in each exhaust gas stream from each monomer recovery system is not to exceed 10 ppm (average for 3-hour period), except as...
NASA Astrophysics Data System (ADS)
Junaidi, Yunus, Muhammad; Triyana, Kuwat; Harsojo, Suharyadi, Edi
2016-04-01
We report our investigation on the effect of chloride ions on controlling the shapes and properties of silver nanorods (AgNRs) synthesized using a polyol method. In this study, we used polyvinyl alcohol (PVA) as a capping agent and sodium chloride (NaCl) as a salt precursor and performed at the oil bath temperature of 140°C. The chloride ions originating from the NaCl serve to control the growth of the silver nanorods. Furthermore, the synthesized silver nanorods were characterized using SEM and XRD. The results showed that besides being able to control the growth of AgCl atoms, the chloride ions were also able to control the growth of multi-twinned-particles into the single crystalline of silver nanorods by micrometer-length. At an appropriate concentration of NaCl, the diameter of silver nanorods decreased significantly compared to that of without chloride ion addition. This technique may be useful since a particular diameter of silver nanorods affects a particular application in the future.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Junaidi; Departement of Physics, Lampung University, Bandar Lampung; Triyana, Kuwat, E-mail: triyana@ugm.ac.id
2016-04-19
We report our investigation on the effect of chloride ions oncontrolling the shapes and properties of silver nanorods(AgNRs) synthesized using a polyol method. In this study, we used polyvinyl alcohol (PVA) as a capping agent and sodium chloride (NaCl) as asalt precursor and performed at the oilbath temperature of 140 °C. The chloride ions originating from the NaCl serve to control the growth of the silver nanorods. Furthermore, the synthesized silver nanorodswere characterized using UV-VIS, XRD, SEM and TEM. The results showed that besides being able to control the growth of AgCl atoms, the chloride ions were also able tomore » control the growth of multi-twinned-particles into the single crystalline silver nanorods by micrometer-length. At an appropriate concentration of NaCl, the diameter of silver nanorodsdecreased significantly compared to that of without chloride ion addition. This technique may be useful since a particular diameter of silver nanorods affects a particular application in the future.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Junaidi, E-mail: junaidi.1982@fmipa.unila.ac.id; Department of Physics, Lampung University, Bandar Lampung; Yunus, Muhammad, E-mail: muhammad.yunus@mail.ugm.ac.id
2016-04-19
We report our investigation on the effect of chloride ions on controlling the shapes and properties of silver nanorods (AgNRs) synthesized using a polyol method. In this study, we used polyvinyl alcohol (PVA) as a capping agent and sodium chloride (NaCl) as a salt precursor and performed at the oil bath temperature of 140°C. The chloride ions originating from the NaCl serve to control the growth of the silver nanorods. Furthermore, the synthesized silver nanorods were characterized using SEM and XRD. The results showed that besides being able to control the growth of AgCl atoms, the chloride ions were alsomore » able to control the growth of multi-twinned-particles into the single crystalline of silver nanorods by micrometer-length. At an appropriate concentration of NaCl, the diameter of silver nanorods decreased significantly compared to that of without chloride ion addition. This technique may be useful since a particular diameter of silver nanorods affects a particular application in the future.« less
Polishing compound for plastic surfaces
Stowell, Michael S.
1995-01-01
A polishing compound for plastic surfaces. The compound contains by weight approximately 4 to 17 parts at least one petroleum distillate lubricant, 1 to 6 parts mineral spirits, 2.5 to 15 parts abrasive particles, and 2.5 to 10 parts water. The abrasive is tripoli or a similar material that contains fine particles silica. Preferably, most of the abrasive particles are less than approximately 10 microns, more preferably less than approximately 5 microns in size. The compound is used on PLEXIGLAS.TM., LEXAN.TM., LUCITE.TM., polyvinyl chloride (PVC) and similar plastic materials whenever a smooth, clear polished surface is desired.
Polishing compound for plastic surfaces
Stowell, M.S.
1993-01-01
A polishing compound for plastic surfaces is disclosed. The compound contains by weight approximately 4 to 17 parts at least one petroleum distillate lubricant, 1 to 6 parts mineral spirits, 2.5 to 15 parts abrasive particles, and 2.5 to 10 parts water. The abrasive is tripoli or a similar material that contains colloidal silica. Preferably, most of the abrasive particles are less than approximately 10 microns, more preferably less than approximately 5 microns in size. The compound is used on PLEXIGLAS{sup TM}, LEXAN{sup TM}, LUCITE{sup TM}, polyvinyl chloride (PVC) and similar plastic materials whenever a smooth, clear polished surface is desired.
Polishing compound for plastic surfaces
Stowell, M.S.
1995-08-22
A polishing compound for plastic surfaces is disclosed. The compound contains by weight approximately 4 to 17 parts at least one petroleum distillate lubricant, 1 to 6 parts mineral spirits, 2.5 to 15 parts abrasive particles, and 2.5 to 10 parts water. The abrasive is tripoli or a similar material that contains fine particles silica. Preferably, most of the abrasive particles are less than approximately 10 microns, more preferably less than approximately 5 microns in size. The compound is used on PLEXIGLAS{trademark}, LEXAN{trademark}, LUCITE{trademark}, polyvinyl chloride (PVC) and similar plastic materials whenever a smooth, clear polished surface is desired. 5 figs.
NASA Astrophysics Data System (ADS)
John, Beena Mary; Joseph, Rani; Sreekumar, K.; Sudha Kartha, C.
2006-11-01
Copper doped methylene blue sensitized poly(vinyl alcohol) (MBPVA)-acrylamide films were fabricated to improve the storage life of recorded gratings. The films were fabricated using gravity settling method and the copper chloride concentration was optimized as 3.18× 10-3 mol/l for a dye concentration of 6.2× 10-4 mol/l. The gratings recorded on the optimized film constitution could be stored for months with stable diffraction efficiency (24%) without any chemical or thermal fixing techniques. The resolution of the material is found to be unaffected with the addition of copper chloride.
Leaching of lead from new unplasticized polyvinyl chloride (uPVC) pipes into drinking water.
Zhang, Yuanyuan; Lin, Yi-Pin
2015-06-01
Unplasticized polyvinyl chloride (uPVC) pipes have been used in the premise plumbing system due to their high strength, long-term durability, and low cost. uPVC pipes, however, may contain lead due to the use of lead compounds as the stabilizer during the manufacturing process. The release of lead from three locally purchased uPVC pipes was investigated in this study. The effects of various water quality parameters including pH value, temperature, and type of disinfectant on the rate of lead release were examined. The elemental mapping obtained using scanning electron microscopy-energy dispersive X-ray spectroscopy (SEM-EDX) confirmed the presence of lead on the inner surfaces of the uPVC pipes and their surface lead weight percentages were determined. The leachable lead concentration for each pipe was determined using high strength acidic EDTA solutions (pH 4, EDTA = 100 mg/L). Lead leaching experiments using tap water and reconstituted tape water under static conditions showed that the rate of lead release increased with the decreasing pH value and increasing temperature. In the presence of monochloramine, lead release was faster than that in the presence of free chlorine.
Antimicrobial allergy from polyvinyl chloride gloves.
Aalto-Korte, Kristiina; Alanko, Kristiina; Henriks-Eckerman, Maj-Len; Jolanki, Riitta
2006-10-01
Contact allergy to plastic gloves is rare. Benzisothiazolinone is a biocide that is mainly used in industrial settings. We first suspected delayed-type contact allergy to benzisothiazolinone from polyvinyl chloride (PVC) gloves in 2004. We looked through our medical records from 1991 to 2005 to find similar cases. We found a total of 8 patients who are allergic to benzisothiazolinone and who had had exacerbations of their hand dermatitis while using PVC gloves. Patch testing revealed that 3 of them had weak allergic or doubtful reactions to the glove materials. Six of them had used Evercare Soft, Medi-Point, or Derma Grip PVC gloves, which in chemical analysis were shown to contain 9 to 32 ppm of benzisothiazolinone. Seven of the patients worked in dentistry or health care and 1 in farming. All of them had had hand dermatitis for many years. To our knowledge, there have been no previous reports of contact allergy to antimicrobial agents in plastic gloves. Benzisothiazolinone is widely used as a biocide in the manufacture of disposable PVC gloves. Small amounts of benzisothiazolinone in the gloves may sensitize those who already have hand dermatitis. We recommend that all patients with hand dermatitis while using PVC gloves should be patch tested with benzisothiazolinone.
Ferri, Marcella; Marcella, Ferri; Chiellini, Federica; Federica, Chiellini; Pili, Giorgio; Giorgio, Pili; Grimaldi, Luca; Luca, Grimaldi; Florio, Elena Tiziana; Pili, Stefania; Stefania, Pili; Cucci, Francesco; Francesco, Cucci; Latini, Giuseppe; Giuseppe, Latini
2012-07-01
Irradiation with 20-25 kGy is a process commonly used for sterilizing poly(vinyl chloride) (PVC) medical devices. Moreover, whole blood and blood components undergo additional irradiation with 25-50 Gy to inhibit the proliferative capacity of lymphocytes and reduce the risk of transfusion-associated graft-vs-host disease (GVHD). Di-(2-ethylhexyl)-phthalate (DEHP) plasticized PVC is extensively used for the production of flexible medical devices including blood bags, but since DEHP is not covalently bound to PVC, it tends to migrate and leach out of the medical device, with harmful consequences for the patients. In this study, the effects of different doses of gamma irradiation on DEHP migration from PVC blood bags was investigated using differential scanning calorimetry (DSC) analysis. Our findings indicate that irradiation with 25-100 Gy reduces the ability of DEHP to migrate from the blood bags, and in the case of a primary container a correlation between the doses of gamma ray irradiation was also observed. In particular, a decrease in DEHP leachability was obtained by increasing the dose of gamma ray irradiation. Copyright © 2012 Elsevier B.V. All rights reserved.
Sakurada, Osamu; Kato, Yasutake; Kito, Noriyoshi; Kameyama, Keiichi; Hattori, Toshiaki; Hashiba, Minoru
2004-02-01
Zirconium oxy-salts were hydrolyzed to form positively charged polymer or cluster species in acidic solutions. The zirconium hydrolyzed polymer was found to react with a negatively charged polyelectrolyte, such as poly(vinyl sulfate), and to form a stoichiometric polyion complex. Thus, colloidal titration with poly(vinyl sulfate) was applied to measure the zirconium concentration in an acidic solution by using a Toluidine Blue selective plasticized poly(vinyl chloride) membrane electrode as a potentiometric end-point detecting device. The determination could be performed with 1% of the relative standard deviation. The colloidal titration stoichiometry at pH < or = 2 was one mol of zirconium per equivalent mol of poly(vinyl sulfate).
Apparatus for inspecting piping
Zollingger, W.T.; Appel, D.K.; Park, L.R.
1995-03-21
An inspection rabbit is described for inspecting piping systems having severe bends therein. The rabbit consists of a flexible, modular body containing a miniaturized eddy current inspection probe, a self-contained power supply for proper operation of the rabbit, an outer surface that allows ease of movement through piping systems and means for transmitting data generated by the inspection device. The body is preferably made of flexible polyvinyl chloride (PVC) tubing or, alternatively, silicone rubber with a shrink wrapping of polytetrafluoroethylene (TEFLON{trademark}). The body is formed to contain the power supply, preferably a plurality of batteries, and a spool of communication wire that connects to a data processing computer external to the piping system. 6 figures.
Toxicity of pyrolysis gases from some cellular polymers
NASA Technical Reports Server (NTRS)
Hilado, C. J.; Machado, A. M.
1978-01-01
Various samples of cellular polymers were evaluated for toxicity of pyrolysis gases, using the screening test method developed at the University of San Francisco. The cellular polymer samples included polyimide, polymethacrylimide, polybismaleimide, polyurethane, polyisocyanurate, polyethylene, polychloroprene, polyvinyl chloride, polystyrene, polysiloxane, and polyphosphazene. The cellular polymers exhibited varying levels of toxicity under these test conditions. Among the rigid cellular polymers, times to death were shortest with the imide type foams and longest with polyvinyl chloride and polystyrene. Among the flexible cellular polymers, times to death were shortest with polyimide and polyester, and longest with polychloroprene and polysiloxane. Increased char yield was not necessarily associated with reduced toxicity.
Biochemistry of whole blood in poly(ethylene-co-ethylacrylate) experimental blood containers.
Horowitz, B; Rowe, A W; Stryker, M H; Van der Sande, J; Waldman, A A; Wong, S C; Gass, J D; Woods, K R
1985-01-01
The biochemical status of whole blood stored in containers fabricated of ethylene ethylacrylate (EEA) film was monitored at several times during 4 weeks of storage at 4 degrees C. Fifteen biochemical indicators were studied to reflect on erythrocyte integrity, cellular metabolism, plasma protein stability, and microaggregate formation. Comparison to storage in polyvinyl chloride (PVC) containers was made by distributing aliquots from each unit of blood among the containers being compared. Whole blood in EEA developed significantly higher levels of plasma hemoglobin, erythrocyte osmotic fragility, and D-glycerate-2,3-diphosphate (2,3-DPG), and somewhat greater glucose utilization, lactate production, and pH. These biochemical differences were not of great magnitude and the data suggest that EEA containers are compatible with the storage of whole blood.
Microorganisms and methods for degrading plant cell walls and complex hydrocarbons
DOE Office of Scientific and Technical Information (OSTI.GOV)
Polne-Fuller, M.
1991-09-24
This patent describes a biologically pure multinucleated marine amoeba having the identifying characteristics of ATCC 40319. The amoeba being capable of digesting algal cell walls and having the further capacity to degrade paraffin, wax, polyethylene, polypropylene, polyvinyl chloride polyvinylidene di-chloride and mixtures thereof.
Impact behaviour of an innovative plasticized poly(vinyl chloride) for the automotive industry
NASA Astrophysics Data System (ADS)
Bernard, C. A.; Bahlouli, N.; Wagner-Kocher, C.; Ahzi, S.; Rémond, Y.
2015-09-01
Plasticized poly(vinyl chloride) (PPVC) is widely used in the automotive industry in the design of structural parts for crashworthiness applications. Thus, it is necessary to study and understand the influence of the mechanical response and mechanical properties of PPVC over a wide range of strain rate, from quasi-static to dynamic loadings. The process is also investigated using different sample thicknesses. In this work, the strain rate effect of a new PPVC is investigated over a wide range of strain rates at three temperatures and for three thicknesses. A modelling of the yield stress is also proposed. The numerical prediction is in good agreement with the experimental results.
NASA Astrophysics Data System (ADS)
Abou Taleb, W. M.; Madi, N. K.; Kassem, M. E.; El-Khatib, A. M.
1996-05-01
The effect of both dopant and neutron radiation on the optical and thermal properties of polyvinyl chloride (PVC) has been studied. The doped samples with Pb and Cd were irradiated with a 14 MeV-neutron fluence in the range 7-28.8 × 10 9 n/cm 2. The optical energy gap Eop exhibits a significant dependence on the type of additive and the neutron irradiation fluence. The specific heat at constant pressure Cp showed a nonmonotonical change with radiation fluence. The results of this study show that PVC:Pb behaves as a crystalline structure which is only slightly affected by neutron irradiation, while PVC:Cd is highly affected.
Sliding of poly(vinyl chloride) on metals studied by Auger electron spectroscopy
NASA Technical Reports Server (NTRS)
Pepper, S. V.
1974-01-01
The sliding of polyvinyl chloride on nickel, iron and S-Monel has been studied by Auger electron spectroscopy. Polymer was not transferred to the metals, rather shear appeared to take place at the interface. The metal was progressively chlorinated as the polymer made multiple passes on the surface. The thickness of this chlorine film was the order of one atomic layer. Electron-induced desorption studies indicate that the chlorine is chemisorbed to the metal. These results are interpreted as evidence for mechanically induced and/or thermal degradation of the polymer during sliding. Degradation products of HCl and Cl2 which chemisorb to the metal are evolved near the interface.
Fox, A J; Collier, P F
1977-01-01
Identification particulars were obtained for over 7000 men who were at some time between 1940 and 1974 exposed to vinyl chloride monomer in the manufacture of polyvinyl chloride. Approximately 99% of these men have been traced and their mortality experience studied. The overall standardised mortality ratio, 75-4, shows a significant reduction compared with the national rates. Four cases of liver cancer were found. Two of these have been confirmed by a panel of liver pathologists as angiosarcoma and two as not angiosarcoma. There is no evidence to support the hypothesis that cancers other than those of the liver are associated with exposure to vinyl chloride monomer. The two cases of angiosarcoma were found in men who had been exposed to high concentrations of the monomer although the second man died only eight years after first exposure. The industry in Great Britain has expanded considerably since the second world war with over 50% of men having entered with the last decade. Conclusions drawn about the effect of vinyl chloride monomer on the mortality experience of men in this industry must consequently be tempered by the reservation that the full impact may not yet be in evidence. PMID:557328
NASA Astrophysics Data System (ADS)
Hajibeygi, Mohsen; Maleki, Mahdiye; Shabanian, Meisam; Ducos, Franck; Vahabi, Henri
2018-05-01
New ternary nanocomposite systems containing polylvinyl chloride (PVC), chitosan modified ZnO (CMZN) nanoparticles and new synthesized polyamide (PA) were designed and prepared by solution casting method. As a potential reinforcement, CMZN was used in PVC system combined with and without PA. Morphology, mechanical, thermal and combustion properties of the all PVC systems were studied. In the presence of the CMZN, PA showed a synergistic effect on improvement of the all investigated properties of PVC. The 5 mass% loss temperature (T5) was increased from 195 °C to 243 °C in PVC/CMZN-PA nanocomposite containing 1 mass% of each PA and CMZN (PZP 2). The peak of heat release rate was decreased from 131 W/g for PVC to 104 W/g for PVC/CMZN-PA nanocomposite containing 3 mass% of each PA and CMZN (PZP 6). According to the tensile tests, compared to the neat PVC, the tensile strength was increased from 35.4 to 53.4 MPa for PZP 6.
Pesticidal seed coats based on azadirachtin-A: release kinetics, storage life and performance.
Nisar, Keyath; Kumar, Jitendra; Arun Kumar, M B; Walia, Suresh; Shakil, Najam A; Parsad, Rajender; Parmar, Balraj S
2009-02-01
Infestation of seeds by pests during storage leads to deterioration in quality. Seed coating is an effective option to overcome the menace. Unlike synthetic fungicidal seed coats, little is known of those based on botanicals. This study aims at developing azadirachtin-A-based pesticidal seed coats to maintain seed quality during storage. Polymer- and clay-based coats containing azadirachtin-A were prepared and evaluated for quality maintenance of soybean seed during storage. Gum acacia, gum tragacanth, rosin, ethyl cellulose, hydroxyethyl cellulose, polyethyl methacrylate, methyl cellulose, polyethylene glycol, polyvinyl chloride, polyvinyl acetate, polyvinyl pyrrolidone and Agrimer VA 6 polymers and the clay bentonite were used as carriers. The time for 50% release (t(1/2)) of azadirachtin-A into water from the seeds coated with the different coats ranged from 8.02 to 21.36 h. The half-life (T(1/2)) of azadirachtin-A in the coats on seed ranged from 4.37 to 11.22 months, as compared with 3.45 months in azadirachtin-A WP, showing an increase by a factor of nearly 1.3-3.3 over the latter. The coats apparently acted as a barrier to moisture to reduce azadirachtin-A degradation and prevented proliferation of storage fungi. Polyethyl methacrylate, polyvinyl acetate and polyvinyl pyrrolidone were significantly superior to the other polymers. Azadirachtin-A showed a significant positive correlation with seed germination and vigour, and negative correlation with moisture content. Effective polymeric carriers for seed coats based on azadirachtin-A are reported. These checked seed deterioration during storage by acting as a barrier to moisture and reduced the degradation of azadirachtin-A.
Yasuhara, A; Katami, T; Okuda, T; Ohno, N; Shibamoto, T
2001-04-01
Exhaust gases from the combustion of newspaper alone, from branches of London plane tree alone, and from newspapers mixed with sodium chloride (NaCl), polyethylene, or poly(vinyl chloride) (PVC) were collected. The samples were analyzed for dioxins by gas chromatography/mass spectrometry. Total amounts of dioxins found in the samples were 0.186 ng/g from newspapers alone, 1.42 ng/g from the branches of London plane, 102 ng/g from newspapers impregnated with sodium chloride (CI wt % = 3.1), 101 ng/g from newspapers impregnated with sodium chloride mixed with PVC (Cl wt % = 2.6), and 146 ng/g from newspapers mixed with PVC (Cl wt % = 5.1). Samples with a higher chloride content produced more dioxins, and there is a clear correlation between dioxin formation and chloride content. The amount of dioxins formed in the samples according to the number of chlorides was Cl5 > Cl4 > Cl6 > Cl7 > Cl8 in PCDD isomers and Cl4 > Cl5 > Cl6 > Cl7 > Cl8 in PCDF isomers, except in the case of newspapers alone. Benzofurans composed 78-92% of the total dioxins formed in the exhaust gases. The higher the number of the chlorides, the lower the production of benzofuran observed. NaCl vaporized at the temperature of the flame used for combustion of the samples (760-1080 degrees C). The results indicate that NaCl and PVC contribute significantly to dioxin formation from waste materials combusted in incinerators.
Three different polyvinyl chloride (PVC) pipe types were subjected to de–ionized water exposures over the course of at least 180 days. Water exposed to the pipe was analyzed for organotin speciation and concentration. Organotin concentrations were the highest during the fir...
21 CFR 175.270 - Poly(vinyl fluoride) resins.
Code of Federal Regulations, 2014 CFR
2014-04-01
...(vinyl fluoride) basic resins have an intrinsic viscosity of not less than 0.75 deciliter per gram as determined by ASTM method D1243-79, “Standard Test Method for Dilute Solution Viscosity of Vinyl Chloride... (ASTM method D1243-79, “Standard Test Method for Dilute Solution Viscosity of Vinyl Chloride Polymers...
40 CFR 61.64 - Emission standard for polyvinyl chloride plants.
Code of Federal Regulations, 2012 CFR
2012-07-01
... was taken to prevent the discharge, and measures adopted to prevent future discharges. (b) Stripper. The concentration of vinly chloride in each exhaust gas stream from each stripper is not to exceed 10... precedes the stripper (or the reactor if the plant has no stripper) in the plant process flow is not to...
40 CFR 61.64 - Emission standard for polyvinyl chloride plants.
Code of Federal Regulations, 2014 CFR
2014-07-01
... was taken to prevent the discharge, and measures adopted to prevent future discharges. (b) Stripper. The concentration of vinly chloride in each exhaust gas stream from each stripper is not to exceed 10... precedes the stripper (or the reactor if the plant has no stripper) in the plant process flow is not to...
40 CFR 61.64 - Emission standard for polyvinyl chloride plants.
Code of Federal Regulations, 2013 CFR
2013-07-01
... was taken to prevent the discharge, and measures adopted to prevent future discharges. (b) Stripper. The concentration of vinly chloride in each exhaust gas stream from each stripper is not to exceed 10... precedes the stripper (or the reactor if the plant has no stripper) in the plant process flow is not to...
Khan, Mohammad Mujahid Ali; Rafiuddin; Inamuddin
2013-05-01
The aim of this study was to investigate the preparation of novel membrane and the characterization of their properties. A new class of polyvinyl chloride (PVC) based polyvinyl alcohol Ce(IV) phosphate composite membrane was successfully prepared by solution casting method. The structural formation was confirmed by X-ray diffraction (XRD), Fourier transform infrared (FTIR) spectroscopy and morphological studies. The thermal property was investigated by thermogravimetry analysis (TGA) method. The order of surface charge density for various electrolytes was found to be LiCl
Dynamic response of a lenticular microlens array using a polyvinyl chloride gel
NASA Astrophysics Data System (ADS)
Li, Xiaolong; Zhou, Zuowei; Ren, Hongwen
2017-12-01
We prepared a lenticular microlens array (LMA) using a polyvinyl chloride (PVC) gel and an interdigitated electrode. By applying a DC voltage to the electrode, the surface of the PVC gel can be waved with an LMA character. When the voltage is removed, the wavy PVC gel can recover its flat surface gradually. With the aid of a polarity-inverted voltage, the recovering time can be largely reduced. The LMA can present a stable dynamic response when it is repetitively impacted by a pulse voltage. The experimental results are given, and the mechanism of reducing the dynamic response time is explained. Our LMA with improved response time has potential applications in sensing, beam steering, biometrics, and displays.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Brown, Suree; Yue, Yanfeng; Kuo, Li-Jung
The need to secure future supplies of energy attracts researchers in several countries to a vast resource of nuclear energy fuel: uranium in seawater (estimated at 4.5 billion tons in seawater). In this study, we developed effective adsorbent fibers for the recovery of uranium from seawater via atom-transfer radical polymerization (ATRP) from a poly- (vinyl chloride)-co-chlorinated poly(vinyl chloride) (PVC-co-CPVC) fiber. ATRP was employed in the surface graft polymerization of acrylonitrile (AN) and tert-butyl acrylate (tBA), precursors for uranium-interacting functional groups, from PVC-co-CPVC fiber. The [tBA]/[AN] was systematically varied to identify the optimal ratio between hydrophilic groups (from tBA) and uranyl-bindingmore » ligands (from AN). The best performing adsorbent fiber, the one with the optimal [tBA]/[AN] ratio and a high degree of grafting (1390%), demonstrated uranium adsorption capacities that are significantly greater than those of the Japan Atomic Energy Agency (JAEA) reference fiber in natural seawater tests (2.42-3.24 g/kg in 42 days of seawater exposure and 5.22 g/kg in 49 days of seawater exposure, versus 1.66 g/kg in 42 days of seawater exposure and 1.71 g/kg in 49 days of seawater exposure for JAEA). Adsorption of other metal ions from seawater and their corresponding kinetics were also studied. The grafting of alternative monomers for the recovery of uranium from seawater is now under development by this versatile technique of ATRP.« less
Zhou, Zhuang; Rajabzadeh, Saeid; Fang, Lifeng; Miyoshi, Taro; Kakihana, Yuriko; Matsuyama, Hideto
2017-08-01
Braid-reinforced hollow fiber membranes with high mechanical properties and considerable antifouling surface were prepared by blending poly(vinyl chloride) (PVC) with poly(vinyl chloride-co-poly(ethylene glycol) methyl ether methacrylate) (poly(VC-co-PEGMA)) copolymer via non-solvent induced phase separation (NIPS). The tensile strength of the braid-reinforced PVC hollow fiber membranes were significantly larger than those of previously reported various types of PVC hollow fiber membranes. The high interfacial bonding strength indicated the good compatibility between the coating materials and the surface of polyethylene terephthalate (PET)-braid. Owing to the surface segregation phenomena, the membrane surface PEGMA coverage increased upon increasing the poly(VC-co-PEGMA)/PVC blending ratio, resulting in higher hydrophilicities and bovine serum albumin (BSA) repulsion. To compare the fouling properties, membranes with similar PWPs were prepared by adjusting the dope solution composition to eliminate the effect of hydrodynamic conditions on the membrane fouling performance. The blend membranes surface exhibited considerable fouling resistance to the molecular adsorption from both BSA solution and activated sludge solution. In both cases, the flux recovered to almost 80% of the initial flux using only water backflush. Considering their great mechanical properties and antifouling resistance to activated sludge solution, these novel membranes show good potential for application in wastewater treatment. Copyright © 2017 Elsevier B.V. All rights reserved.
[Survey of plasticizers in polyvinyl chloride toys].
Abe, Yutaka; Yamaguchi, Miku; Mutsuga, Motoh; Hirahara, Yoshichika; Kawamura, Yoko
2012-01-01
Plasticizers in 101 samples of polyvinyl chloride (PVC) toys on the Japanese market were surveyed. No phthalates were detected in designated toys, though bis(2-ethylhexyl)phthalate, diisononyl phthalate, diisobutyl phthalate, dibutyl phthalate, diisodecyl phthalate and benzyl butyl phthalate were detected in more than half of other toys. 2,2,4-Tributyl-1,3-pentanediol diisobutylate, o-acetyl tributyl citrate, adipates and diacetyl lauroyl glycerol, which are alternative plasticizers to phthalates, were detected. The results of structural analysis confirmed the presence of di(2-ethylhexyl)terephthalate, tributyl citrate, diisononyl 1,2-cyclohexanedicarboxylate and neopentyl glycol esters; these have not previonsly been reported in Japan. There appears to be a shift in plasticizers used for designated toys from phthalates to new plasticizers, and the number of different plasticizers is increasing.
Stability of Dexmedetomidine in 0.9% Sodium Chloride in Two Types of Intravenous Infusion Bags.
Marquis, Kathleen; Hohlfelder, Benjamin; Szumita, Paul M
2017-01-01
Dexmedetomidine is a frequently used sedative in the critical care setting. It is commercially available as a 4-mg/mL premixed compound or as 200-mcg/2-mL vials that must be further diluted prior to administration. However, limited data exist regarding the stability of dexmedetomidine admixtures compounded from the 200-mcg/2-mL vials, particularly for durations greater than 48 hours. Therefore, we performed stability testing on compounded dexmedetomidine prepared in two types of intravenous infusion bags for 14 days. Dexmedetomidine is available as 200-mcg/2-mL vials for dilution, 80-mcg/20-mL single-dose vials, and as 200-mcg/50-mL and 400-mcg/100-mL glass bottles. The stability of dexmedetomidine admixtures has previously been tested for 48 hours. The purpose of this analysis was to test the stability of dexmedetomidine admixtures for 14 days. Six dexmedetomidine admixtures of 200 mcg/50 mL were compounded in polyvinyl chloride and non-polyvinyl chloride bags, three of which were stored under refrigeration and three of which were kept at room temperature. High-performance liquid chromatography testing was performed to determine the concentration at Days 1 through 14. Stability was determined by taking the mean concentration of samples taken from each bag. All samples were tested in duplicate. A sample was considered stable if the concentration was greater than 90% of the original concentration. All samples retained over 90% of the drug under their respective storage conditions for the duration of the study. At time 0, the concentration of dexmedetomidine was between 3.99 mcg/mL and 4.01 mcg/mL. On Day 14, the mean concentration was between 95.8% and 98.9%, depending on the bag type and storage condition. The pH remained between 4.7 and 5.8 during the study period as has previously been reported in the literature. Dexmedetomidine admixtures of 200 mcg/50 mL were stable in both polyvinyl chloride bags and non-polyvinyl chloride bags for 14 days under refrigeration and 48 hours at room temperature. This represents the longest time allowable under United States Pharmacopeia Chapter <797> without the need for sterility testing. Copyright© by International Journal of Pharmaceutical Compounding, Inc.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hagmar, L.; Akesson, B.; Nielsen, J.
1990-01-01
To study whether exposure to low levels of vinyl chloride monomer (VCM) causes increased risk for cancer morbidity and death from ischemic heart disease, a cohort study was performed among 2,031 male workers at a polyvinyl chloride (PVC) processing plant who had been employed for at least 3 months during the period 1945-1980. An almost significantly increased total mortality (SMR = 116, 95% CI 99-136) was found. Deaths caused by violence or intoxication were significantly increased (SMR = 153, 95% CI 109-213), but not deaths from ischemic heart disease (SMR = 100, 95% CI 73-135). A significant increase in totalmore » cancer morbidity was observed (SMR = 128, 95% CI 101-161). Respiratory cancers were significantly increased (SMR = 213, 95% CI 127-346). Furthermore, six brain tumors (vs. 2.6 expected) were observed. This increase, however, was not significant (SMR = 229, 95% CI 84-498). No liver hemangiosarcoma was observed. Applying a latency period of greater than or equal to 10 years from start of employment did not change the risk patterns. There were no significant exposure-response associations between exposure estimates for VCM, asbestos, and plasticizers and cancer morbidity.« less
Kuiper, Melanie W.; Wullings, Bart A.; Akkermans, Antoon D. L.; Beumer, Rijkelt R.; van der Kooij, Dick
2004-01-01
The need for protozoa for the proliferation of Legionella pneumophila in aquatic habitats is still not fully understood and is even questioned by some investigators. This study shows the in vivo growth of L. pneumophila in protozoa in aquatic biofilms developing at high concentrations on plasticized polyvinyl chloride in a batch system with autoclaved tap water. The inoculum, a mixed microbial community including indigenous L. pneumophila originating from a tap water system, was added in an unfiltered as well as filtered (cellulose nitrate, 3.0-μm pore size) state. Both the attached and suspended biomasses were examined for their total amounts of ATP, for culturable L. pneumophila, and for their concentrations of protozoa. L. pneumophila grew to high numbers (6.3 log CFU/cm2) only in flasks with an unfiltered inoculum. Filtration obviously removed the growth-supporting factor, but it did not affect biofilm formation, as determined by measuring ATP. Cultivation, direct counting, and 18S ribosomal DNA-targeted PCR with subsequent sequencing revealed the presence of Hartmannella vermiformis in all flasks in which L. pneumophila multiplied and also when cycloheximide had been added. Fluorescent in situ hybridization clearly demonstrated the intracellular growth of L. pneumophila in trophozoites of H. vermiformis, with 25.9% ± 10.5% of the trophozoites containing L. pneumophila on day 10 and >90% containing L. pneumophila on day 14. Calculations confirmed that intracellular growth was most likely the only way for L. pneumophila to proliferate within the biofilm. Higher biofilm concentrations, measured as amounts of ATP, gave higher L. pneumophila concentrations, and therefore the growth of L. pneumophila within engineered water systems can be limited by controlling biofilm formation. PMID:15528550
Xu, Miao; Jin, Boya; He, Rui; Ren, Hongwen
2016-04-18
We report a new approach to preparing a lenticular microlens array (LMA) using polyvinyl chloride (PVC)/dibutyl phthalate (DBP) gels. The PVD/DBP gels coated on a glass substrate form a membrane. With the aid of electrostatic repulsive force, the surface of the membrane can be reconfigured with sinusoidal waves by a DC voltage. The membrane with wavy surface functions as a LMA. By switching over the anode and cathode, the convex shape of each lenticular microlens in the array can be converted to the concave shape. Therefore, the LMA can present a large dynamic range. The response time is relatively fast and the driving voltage is low. With the advantages of compact structure, optical isotropy, and good mechanical stability, our LMA has potential applications in imaging, information processing, biometrics, and displays.
NASA Astrophysics Data System (ADS)
Chen, J.; Nie, X. A.; Jiang, J. C.; Zhou, Y. H.
2018-01-01
A natural plasticizer cardanol derivatives glycidyl ether (CGE) was synthesized and employed as a plasticizer for the poly(vinyl chloride). The effect of CGE on thermal degradation of PVC films and its plasticizing mechanism were firstly reported. The molecular structure of CGE was characterized with Fourier transform infrared spectroscopy (FTIR). Thermal properties, degradation properties and compatibility of the PVC films were investigated by Differential scanning calorimeter analysis (DSC), Thermogravimetric analysis (TGA) and FTIR, respectively. Compared with the commercial plasticizers dioctylphthalate (DOP), CGE can endow PVC film with a decrease of 4.31 °C in glass transition temperature (Tg), an increase of 24.01 °C and 25.53 °C in 10% weight loss (T 10) and 50% weight loss (T 50) respectively, and a higher activetion energy of thermal degradation (Ea ).
NASA Astrophysics Data System (ADS)
Zuñiga-Zamorano, Ivette; Meléndez-Ortiz, H. Iván; Costoya, Alejandro; Alvarez-Lorenzo, Carmen; Concheiro, Angel; Bucio, Emilio
2018-01-01
Radiation-grafting of pH-responsive methacrylic acid (MAA) onto poly(vinyl chloride) (PVC) was carried out by the pre-irradiation method using gamma rays, which demonstrated to be an efficient and fast procedure for obtaining PVC-g-MAA copolymers. The influence of preparation conditions, such as absorbed dose, monomer concentration, reaction time, and reaction temperature on the grafting yield was studied. The grafting of MAA onto PVC catheters was confirmed by means of Fourier transform infrared spectroscopy (FT-IR), thermogravimetry analysis (TGA), and differential scanning calorimetry (DSC). The pH-responsiveness of the grafted copolymers (critical point 8.5) was measured by swelling under cyclic changes in the pH of the medium. Interestingly, PVC-g-MAA showed enhanced capability to immobilize benzalkonium chloride and, particularly, ciprofloxacin and to sustain the release this antimicrobial agent at both acid and alkaline pH. Tests carried out with Escherichia coli, Pseudomonas aeruginosa, and Staphylococcus aureus point out that the developed functionalized catheters may play a role in the prevention/management of urinary tract infections.
CONTECH(R) A-2000 polyvinyl chloride (PVC) plastic pipe.
DOT National Transportation Integrated Search
2015-03-01
Determine the effectiveness and long-term durability of the Contech A-2000 PVC pipe : in an irrigation application. This type of pipe may prove to be a viable alternative to : reinforced concrete pipe (RCP).
PVC removal from mixed plastics by triboelectrostatic separation.
Park, Chul-Hyun; Jeon, Ho-Seok; Park, Jai-Koo
2007-06-01
Ever increasing oil price and the constant growth in generation of waste plastics stimulate a research on material separation for recycling of waste plastics. At present, most waste plastics cause serious environmental problems due to the disposal by reclamation and incineration. Particularly, polyvinyl chloride (PVC) materials among waste plastics generates hazardous HCl gas, dioxins containing Cl, and so on, which lead to air pollution and shorten the life of incinerator, and it makes difficultly recycling of other plastics. Therefore, we designed a bench scale triboelectrostatic separator for PVC removal from mixed plastics (polyvinyl chloride/polyethylene terephthalate), and then carried out material separation tests. In triboelectrostatic separation, PVC and PET particles are charged negatively and positively, respectively, due to the difference of the work function of plastics in tribo charger of the fluidized-bed, and are separated by means of splitter through an opposite electric field. In this study, the charge efficiency of PVC and PET was strongly dependent on the tribo charger material (polypropylene), relative humidity (below 30%), air velocity (over 10 m/s), and mixture ratio (PET:PVC=1:1). At the optimum conditions (electrode potential of 20 kV and splitter position of -2 cm), PVC rejection and PET recovery in PET products were 99.60 and 98.10%, respectively, and the reproducibility of optimal test was very good (+/-1%). In addition, as a change of splitter position, we developed the technique to recover high purity PET (over 99.99%) although PET recovery decreases by degrees.
Respiratory illness caused by overheating of polyvinyl chloride.
Froneberg, B; Johnson, P L; Landrigan, P J
1982-01-01
On 9 August 1979, 62 (30.8%) of 201 workers and one of 60 management personnel in a polyvinyl chloride (PVC) fabricating plant developed acute upper and lower respiratory irritation, headache, nausea, and fainting. All were taken to hospital; none died. Sixty of the patients were women. Interviews two weeks later with 57 affected and 14 unaffected workers disclosed that illness had followed exposure to fumes from an overheated (362 degrees C) PVC extruding machine. Fumes were emitted from 1100 until 1150; cases occurred from 1100 until late afternoon. All workers who became ill worked west of the overheated extruder, and the affected manager had visited that area. The earliest cases occurred closest to the machine, and incidence decreased (from 53.3% to 15.4%) with distance westward. This pattern was consistent with plant ventilation. Incidence rates in men and women did not differ (p greater than 0.1). At two and 14 weeks, pulmonary function testing of workers with persistent pulmonary symptoms showed abnormalities in 13 of 16 and in 9 of 11 respectively; the group with persistent symptoms contained an excess of non-smokers and of those with previous respiratory illnesses. One kilogram of PVC heated to 300 degrees C releases an estimated 12.9 g of hydrochloric acid (HCl) and 4.9 g of carbon monoxide (CO). We attributed the outbreak to exposure to toxic HCl and CO and rejected the hypothesis of mass psychogenic illness. PMID:7093150
Jikihara, Atsushi; Ohashi, Reina; Kakihana, Yuriko; Higa, Mitsuru; Kobayashi, Kenichi
2013-01-02
Random-type anion-exchange membranes (AEMs) have been prepared by blending poly(vinyl alcohol) (PVA) and the random copolymer-type polycation, poly(vinyl alcohol-co-methacryloyl aminopropyl trimethyl ammonium chloride) at various molar percentages of anion-exchange groups to vinyl alcohol groups, Cpc, and by cross-linking the PVA chains with glutaraldehyde (GA) solution at various GA concentrations, CGA. The characteristics of the random-type AEMs were compared with blend-type AEMs prepared in our previous study. At equal molar percentages of the anion exchange groups, the water content of the random-type AEMs was lower than that of the blend-type AEMs. The effective charge density of the random-type AEMs increased with increasing Cpc and reached a maximum value. Further, the maximum value of the effective charge density increased with increasing CGA. The maximum value of the effective charge density, 0.42 mol/dm3, was obtained for the random-type AEM with Cpc = 4.2 mol % and CGA = 0.15 vol %. A comparison of the random-type and blend-type AEMs with almost the same Cpc showed that the random-type AEMs had lower membrane resistance than the blend-type ones. The membrane resistance and dynamic transport number of the random-type AEM with Cpc = 6.0 mol % and CGA = 0.15 vol % were 4.8 Ω cm2 and 0.83, respectively.
Jikihara, Atsushi; Ohashi, Reina; Kakihana, Yuriko; Higa, Mitsuru; Kobayashi, Kenichi
2012-01-01
Random-type anion-exchange membranes (AEMs) have been prepared by blending poly(vinyl alcohol) (PVA) and the random copolymer-type polycation, poly(vinyl alcohol-co-methacryloyl aminopropyl trimethyl ammonium chloride) at various molar percentages of anion-exchange groups to vinyl alcohol groups, Cpc, and by cross-linking the PVA chains with glutaraldehyde (GA) solution at various GA concentrations, CGA. The characteristics of the random-type AEMs were compared with blend-type AEMs prepared in our previous study. At equal molar percentages of the anion exchange groups, the water content of the random-type AEMs was lower than that of the blend-type AEMs. The effective charge density of the random-type AEMs increased with increasing Cpc and reached a maximum value. Further, the maximum value of the effective charge density increased with increasing CGA. The maximum value of the effective charge density, 0.42 mol/dm3, was obtained for the random-type AEM with Cpc = 4.2 mol % and CGA = 0.15 vol %. A comparison of the random-type and blend-type AEMs with almost the same Cpc showed that the random-type AEMs had lower membrane resistance than the blend-type ones. The membrane resistance and dynamic transport number of the random-type AEM with Cpc = 6.0 mol % and CGA = 0.15 vol % were 4.8 Ω cm2 and 0.83, respectively. PMID:24958543
Effect of copper chloride on the emissions of PCDD/Fs and PAHs from PVC combustion.
Wang, Dongli; Xu, Xiaobai; Zheng, Minghui; Chiu, Chung H
2002-09-01
The influences of temperature, air flow and the amount of copper chloride upon the types and amount of the toxic emissions such as polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans (PCDD/Fs) and polycyclic aromatic hydrocarbons (PAHs) during combustion of polyvinyl chloride (PVC) were investigated. The mechanism concerning the effect of temperature and copper chloride on the PCDD/Fs and PAHs formation was discussed. The results shown that without copper chloride, trace amounts of PCDD/Fs and large amounts of PAHs were found in the emissions from the pure PVC combustion under various combustion conditions. The addition of copper chloride enhanced PCDD/Fs formation, but it seems that the formation of PAHs decreased with increasing amount of copper chloride, and greater total amount of PAHs were produced at the higher temperature under our experimental conditions.
Masadome, Takashi; Yamagishi, Yuichi; Takano, Masaki; Hattori, Toshiaki
2008-03-01
A potentiometric titration method using a cationic surfactant as an indicator cation and a plasticized poly(vinyl chloride) membrane electrode sensitive to the cationic surfactant is proposed for the determination of polyhexamethylene biguanide hydrochloride (PHMB-HCl), which is a cationic polyelectrolyte. A sample solution of PHMB-HCl containing an indicator cation (hexadecyltrimethylammonium ion, HTA) was titrated with a standard solution of an anionic polyelectrolyte, potassium poly(vinyl sulfate) (PVSK). The end-point was detected as a sharp potential change due to an abrupt decrease in the concentration of the indicator cation, HTA, which is caused by its association with PVSK. The effects of the concentrations of HTA ion and coexisting electrolytes in the sample solution on the degree of the potential change at the end-point were examined. A linear relationship between the concentration of PHMB-HCl and the end-point volume of the titrant exists in the concentration range from 2.0 x 10(-5) to 4.0 x 10(-4) M in the case that the concentration of HTA is 1.0 x 10(-5) M, and that from 1.0 x 10(-6) to 1.2 x 10(-5) M in the case that the concentration of HTA is 5.0 x 10(-6) M, respectively. The proposed method was applied to the determination of PHMB-HCl in some contact-lens detergents.
Friction loss in straight pipes of unplasticized polyvinyl chloride.
Iwasaki, T; Ojima, J
1996-01-01
In order to design proper ductwork for a local exhaust system, airflow characteristics were investigated in straight pipes of unplasticized polyvinyl chloride (PVC). A linear decrease in static pressure was observed downstream at points from the opening of the VU pipes (JIS K 6741) located at distances greater than 10 times the pipe diameter, for velocities ranging between 10.18-36.91 m/s. Roughness inside pipes with small diameters was found to be 0.0042-0.0056 mm and the friction factor was calculated on the basis of Colebrook's equation for an airflow transition zone. An extended friction chart was then constructed on the basis of the roughness value and the friction factor. This chart can be applied when designing a local exhaust system with the ducts of diameters ranging from 40 to 900 mm. The friction loss of the PVC pipe was found to be approximately 2/3 of that of a galvanized steel pipe.
Adaptive microlens array based on electrically charged polyvinyl chloride/dibutyl phthalate gel
NASA Astrophysics Data System (ADS)
Xu, Miao; Ren, Hongwen
2016-09-01
We prepared an adaptive microlens array (MLA) using a polyvinyl chloride/dibutyl phthalate gel and an indium-tin-oxide (ITO) glass substrate. The gel forms a membrane on the glass substrate and the ITO electrode has a ring array pattern. When the membrane is electrically charged by a DC voltage, the surface of the membrane above each circular electrode in the ring array can be deformed with a convex shape. As a result, the membrane functions as an MLA. By applying a voltage from 20 to ˜65 V to the electrode, the focal length of each microlens can be tuned from 300 to ˜160 μm. The dynamic response time can by reduced largely by changing the polarity of the DC voltage. Due to the advantages of optical isotropy, compact structure, and good stability, our MLA has potential applications in imaging, biometrics, and electronic displays.
Chang, Chang-Tang; Chiou, Chyow-Shan
2006-05-01
This study attempts to assess the effectiveness of control strategies for reducing volatile organic compound (VOC) emission from the polyvinyl chloride (PVC) wallpaper production industry. In Taiwan, methyl ethyl ketone, TOL, and cyclohexanone have comprised the major content of solvents, accounting for approximately 113,000 t/yr to avoid excessive viscosity of plasticizer dioctyl phthalate (DOP) and to increase facility in working. Emissions of these VOCs from solvents have caused serious odor and worse air quality problems. In this study, 80 stacks in five factories were tested to evaluate emission characteristics at each VOC source. After examining the VOC concentrations in the flue gases and contents, the VOC emission rate before treatment and from fugitive sources was 93,000 and 800 t/yr, respectively. In this study, the semiwet electrostatic precipitator is recommended for use as cost-effective control equipment.
NASA Astrophysics Data System (ADS)
Haryono, Agus; Triwulandari, Evi; Jiang, Pingping
2017-01-01
Plasticizer molecules are low molecular weight compounds that are widely used in polymer industries especially in polyvinyl chloride (PVC) resin. As an additive in PVC resin, the important role of plasticizer molecules is to improve the flexibility and processability of PVC by lowering the glass transition temperature (Tg). However, the commercial plasticizer like di(2-ethylhexyl)phthalate (DEHP) is known to cause liver cancer, at least in laboratory rats. DEHP can leach out from PVC into blood, certain drug solutions and fatty foods, which has been detected in the bloodstream of patients undergoing transfusion. Vegetable oil based plasticizers have some attractive properties such as non-toxic, bio-degradable, good heat and light stability, renewable resources, and environmentally friendly. Here we discussed the main results and development of vegetable oil based plasticizer, and especially palm oil based plasticizer. The interaction between plasticizer and polymer was discussed from the properties of the plasticized polymeric material.
Design Guide: Designing and Building High Voltage Power Supplies. Volume 2
1988-08-01
and edges. * Isolation system: * One layer ol’ Tedlar: or type 120 glass fabric with a compatible resin : or finish. 199 5.4.2 Composite Joints...plastics Cellulose esters Asphalt Cork Chloride flux Epoxy resins Copper (bare) Masonite Fiber board Melamine resins Greases Nylon Polyvinyl chloride resins ...cycloaliphatic epoxy to a level inferior to the porcelain. In one application having a glass -cloth epoxy- based laminate coated with cycloaliphatic epoxy the
Passivation-free solid state battery
Abraham, Kuzhikalail M.; Peramunage, Dharmasena
1998-01-01
This invention pertains to passivation-free solid-state rechargeable batteries composed of Li.sub.4 Ti.sub.5 O.sub.12 anode, a solid polymer electrolyte and a high voltage cathode. The solid polymer electrolyte comprises a polymer host, such as polyacrylonitrile, poly(vinyl chloride), poly(vinyl sulfone), and poly(vinylidene fluoride), plasticized by a solution of a Li salt in an organic solvent. The high voltage cathode includes LiMn.sub.2 O.sub.4, LiCoO.sub.2, LiNiO.sub.2 and LiV.sub.2 O.sub.5 and their derivatives.
NASA Astrophysics Data System (ADS)
Fontanilla-Urdaneta, R. C.; Hernández-Garay, M. P.; Olivares-Pérez, A.; Páez-Trujillo, G.; Fuentes-Tapia, I.
2008-02-01
Experimental results to the saturation and diffraction efficiency from holographic gratings are presented in this investigation. The experiments were carried out during real time holographic gratings formation. Dichromated poly(vinyl alcohol) was doped with nickel(II) chloride hexahydrate and it is used like optical material. The influence of the hologram parameters to get the maximum diffraction efficiency is studied at room conditions. This study contributes to get more information about the behavior of this material for holographic gratings recording.
IMMUNOTOXICITY OF INDIVIDUAL ORGANOTIN COMPOUNDS IN SPRAGUE-DAWLEY RATS
Organotins, used as stabilizers for polyvinyl chloride pipe, leach into drinking water from supply pipes and may cause multisystem toxicity, including immunotoxicity. We assessed immune function in Sprague-Dawley rats exposed to dibutyltin dichloride (DBTC) or dimethyltin dichlor...
Medical vest broadens treatment capability
NASA Technical Reports Server (NTRS)
Johnson, G. S.
1970-01-01
Universal sized vest, with specially tailored pockets designed to hold medical supplies, provides first aid/first care medical teams with broadened on-site capability. Vest is made of nylon, tough fibrous materials, and polyvinyl chloride. Design facilitates rapid donning, doffing, and adjustment.
Yancey, E J; Hunt, M C; Dikeman, M E; Addis, P B; Katsanidis, E
2001-10-01
Grain-finished, high-percentage Charolais steers (n = 36) were selected for uniformity. Immediately after jugular vein exsanguination, 27 steers were infused at 10% of live weight via the carotid artery with a solution developed by MPSC, Inc. (St. Paul, MN) consisting of 98.52% water, 0.97% saccharides, 0.23% sodium chloride, and 0.28% phosphate blend plus either 500 ppm vitamin C (MPSC+C; n = 9), 500 ppm vitamin E (MPSC+E; n = 9), or 500 ppm vitamin C + 500 ppm vitamin E (MPSC+C+E; n = 9). Uninfused controls (CON) were exsanguinated conventionally. Carcasses were fabricated at 48 h postmortem. Longissimus thoracis (LT), psoas major (PM), and semimembranosus (SM) muscles were removed, vacuum-packaged, and stored at 2 degrees C until 14 d postmortem. Then, steaks 2.54 cm thick were sliced from the three muscles, placed on foam trays, and overwrapped with polyvinyl chloride film. Ground beef (GB) was formulated from the quadriceps femoris to contain 20% fat, mounded into 0.45-kg portions, placed on styrofoam trays, and wrapped with polyvinyl chloride film. Steaks were visually evaluated for uniformity and initial color on display d 0. Instrumental color measurements of L*, a*, b* and trained sensory panel color evaluations were obtained daily for 4 d (PM and GB) or 5 d (LT and SM) of display. No display time x treatment interaction existed for L*, a*, or b* values. The LT from CON cattle had more uniform color (P < 0.05) and was more cherry red than that from all infused cattle on d 0. Visual scores indicated that GB from MPSC+E cattle was more red (P < 0.05) than that from MPSC+C infused cattle throughout display, and GB from MPSC+E cattle was more red (P < 0.05) than that from CON cattle for the last 3 d of display. The vascular infusion solutions generally did not improve color or display-color stability of steaks, but the infusion solution with vitamin E did improve display-color stability of GB.
Heterogeneous electro-Fenton catalyst for 1-butylpyridinium chloride degradation.
Meijide, Jessica; Pazos, Marta; Sanromán, Maria Ángeles
2017-10-15
The application of the electro-Fenton process for organic compound mineralisation has been widely reported over the past years. However, operational problems related to the use of soluble iron salt as a homogeneous catalyst involve the development of novel catalysts that are able to operate in a wide pH range. For this purpose, polyvinyl alcohol-alginate beads, containing goethite as iron, were synthesised and evaluated as heterogeneous electro-Fenton catalyst for 1-butylpyridinium chloride mineralisation. The influence of catalyst dosage and pH solution on ionic liquid degradation was analysed, achieving almost total oxidation after 60 min under optimal conditions (2 g/L catalyst concentration and pH 3). The results showed good catalyst stability and reusability, although its effectiveness decreases slightly after three successive cycles. Furthermore, a plausible mineralisation pathway was proposed based on the oxidation byproducts determined by chromatographic techniques. Finally, the Microtox® test revealed notable detoxification after treatment which demonstrates high catalyst ability for pyridinium-based ionic liquid degradation by the electro-Fenton process.
Ignition characteristics of some aircraft interior fabrics
NASA Technical Reports Server (NTRS)
Hilado, C. J.; Brandt, D. L.
1978-01-01
Six samples of aircraft interior fabrics were evaluated with regard to resistance to ignition by radiant heat. Five samples were aircraft seat upholstery fabrics and one sample was an aircraft curtain fabric. The aircraft seat fabrics were 100% wool (2 samples), 83% wool/17% nylon, 49% wool/51% polyvinyl chloride, and 100% rayon. The aircraft curtain fabric was 92% modacrylic/8% polyester. The five samples of aircraft seat upholstery fabrics were also evaluated with regard to resistance to ignition by a smoldering cigarette. The four samples of wool-containing aircraft seat fabrics appeared to be superior to the sample of rayon seat fabric in resistance to ignition, both by radiant heat and by a smoldering cigarette.
Recycling of spent lithium-ion battery with polyvinyl chloride by mechanochemical process.
Wang, Meng-Meng; Zhang, Cong-Cong; Zhang, Fu-Shen
2017-09-01
In the present study, cathode materials (C/LiCoO 2 ) of spent lithium-ion batteries (LIBs) and waste polyvinyl chloride (PVC) were co-processed via an innovative mechanochemical method, i.e. LiCoO 2 /PVC/Fe was co-grinded followed by water-leaching. This procedure generated recoverable LiCl from Li by the dechlorination of PVC and also generated magnetic CoFe 4 O 6 from Co. The effects of different additives (e.g. alkali metals, non-metal oxides, and zero-valent metals) on (i) the conversion rates of Li and Co and (ii) the dechlorination rate of PVC were investigated, and the reaction mechanisms were explored. It was found that the chlorine atoms in PVC were mechanochemically transformed into chloride ions that bound to the Li in LiCoO 2 to form LiCl. This resulted in reorganization of the Co and Fe crystals to form the magnetic material CoFe 4 O 6 . This study provides a more environmentally-friendly, economical, and straightforward approach for the recycling of spent LIBs and waste PVC compared to traditional processes. Copyright © 2017. Published by Elsevier Ltd.
Measuring and Modeling Surface Sorption Dynamics of OPFRs in Stainless Steel Empty Chambers
Organophosphorus flame retardants (OPFRs) are produced and used widely as alternative additives in building materials and consumer products such as spray polyurethane foam (SPF), polyvinyl chloride flooring, electrical and electronic products, furniture, textile coatings, and pla...
LINERS FOR SANITARY LANDFILLS AND CHEMICAL AND HAZARDOUS WASTE DISPOSAL SITES
This report lists addresses of sanitary landfills and chemical and hazardous waste disposal sites and holding ponds with some form of impermeable lining. Liners included are polyethylene, polyvinyl chloride, Hypalon R, ethylene propylene diene monomer, butyl rubber, conventional ...
Singh, Rina; Singh, Jagjit; Singh, Ramanpreet; Nanda, Sonia
2013-01-01
Objective:To determine the effect of different retraction cord medicaments on surface detail reproduction of polyvinyl siloxane impression materials and compare this effect on any two brands of commercially available polyvinyl siloxane impression materials. Material and methods: Four stainless steel dies were made according to ADA specification no.19. Three dies were treated with aluminium chloride (5%), ferric sulphate (13.3%) and epinephrine (0.1%) while the fourth one was left untreated to serve as control. Two impression materials (Dentsply and 3M ESPE) were used. Results: All the three medicaments adversely affected the surface detail reproduction of both the brands of the polyvinyl siloxane impression materials. These effects were statistically significant as compared to untreated control. The impressions of 3M ESPE brand have shown better surface detail reproduction as compared to Dentsply impression material. Conclusion: Surface detail reproduction of the polyvinyl siloxane impression materials is adversely affected by the retraction cord medicaments. The presence of moisture or any traces of the medicaments should be removed from the tooth surface to provide a dry field for the correct reproduction of the surface detail of these materials. Key words:Polyvinyl Siloxane, retraction cord medicaments, surface detail reproduction. PMID:24455069
New high-frequency weldable polyolefin films.
Kelch, R
2000-05-01
There is an increasing desire for plastic films that can be sealed using high-frequency energy. Tests on new high-frequency polyolefin film structures are reported, which compare them with the characteristics and performance of poly(vinyl chloride), ethylene-vinyl acetate and thermoplastic polyurethane films.
TRACER DISPERSION STUDIES FOR HYDRAULIC CHARACTERIZATION OF PIPES
A series of experiments were conducted at the U. S. Environmental Protection Agency (EPA) Test & Evaluation (T&E) Facility in Cincinnati, Ohio, to quantify longitudinal dispersion of a sodium fluoride tracer in polyvinyl chloride (PVC) pipe and ductile iron pipe under laminar, tr...
Lau, Arthur C W; Lam, S M; Yan, W W
2014-02-01
OBJECTIVES. To compare three endotracheal tubes for leakage across the cuff (microaspiration) under a comprehensive set of simulated clinical situations. These were the Mallinckrodt TaperGuard (Covidien, US) with a tapered polyvinyl chloride cuff; the KimVent Microcuff (Kimberly-Clark Health Care, US) with a cylindrical polyurethane cuff; and a conventional Portex (Smiths Medical International Ltd, UK) with a globular polyvinyl chloride cuff. DESIGN. A benchtop experimental study. SETTING AND MATERIALS. A silicone cylinder serving as the model trachea was intubated with each of the three endotracheal tubes, one at a time. A total of 20 mL of water were added above the cuff and leakage measured every minute for 20 minutes under five simulated mechanical ventilation scenarios, including different positive end-expiratory pressure levels, and disconnection with and without spontaneous breathing efforts. Each scenario was studied under three cuff pressures of 10, 20 and 30 cm H2O, and then repeated with the application of a continuous suction force of 200 cm H2O, and leakage measured every minute for 3 minutes. RESULTS. The outcome of interest was the cumulative amount of leakage. The Microcuff endotracheal tubes with an ultrathin polyurethane cuff consistently provided the best protection against microaspiration under all simulated clinical situations, followed by TaperGuard with a tapered cuff, and lastly Portex with a globular polyvinyl chloride cuff. Clinical scenarios associated with the greatest leakage were mechanical ventilation with zero positive end-expiratory pressure, circuit disconnection with spontaneous breathing efforts, application of suction, and a low cuff pressure. CONCLUSIONS. Microcuff endotracheal tubes outperformed TaperGuard and Portex endotracheal tubes in preventing microaspiration, which is one of the major mechanisms for ventilator-associated pneumonia.
Passivation-free solid state battery
Abraham, K.M.; Peramunage, D.
1998-06-16
This invention pertains to passivation-free solid-state rechargeable batteries composed of Li{sub 4}Ti{sub 5}O{sub 12} anode, a solid polymer electrolyte and a high voltage cathode. The solid polymer electrolyte comprises a polymer host, such as polyacrylonitrile, poly(vinyl chloride), poly(vinyl sulfone), and poly(vinylidene fluoride), plasticized by a solution of a Li salt in an organic solvent. The high voltage cathode includes LiMn{sub 2}O{sub 4}, LiCoO{sub 2}, LiNiO{sub 2} and LiV{sub 2}O{sub 5} and their derivatives. 5 figs.
Compatibility of butorphanol and droperidol in 0.9% sodium chloride injection.
Chen, Fu-Chao; Fang, Bao-Xia; Li, Peng; Yang, Jin-Guo; Zhou, Ben-Hong
2013-03-15
The compatibility and stability of butorphanol tartrate and droperidol in polyvinyl chloride (PVC) bags and glass bottles stored at 4°C and 25°C for up to 15 days were studied. Admixtures were assessed initially and for 15 days after preparation in PVC bags and glass bottles using 0.9% sodium chloride injection as a diluent and stored at 4°C and 25°C. The initial drug concentrations were 0.08 mg/mL for butorphanol tartrate and 0.05 mg/mL for droperidol. Samples were withdrawn from each container immediately after preparation and at predetermined intervals (2, 4, 8, 24, 48, 72, 120, 168, 240, and 360 hours after preparation). The solutions were visually inspected for precipitation, cloudiness, and discoloration at each sampling interval. Drug concentrations were determined using a validated high-pressure liquid chromatography method. After 15 days of storage, all formulations tested retained >98% of the initial concentrations of both drugs. The drug mixtures were clear in appearance, and no color change or precipitation was observed. Throughout this period, pH values remained stable. Admixtures of butorphanol tartrate 0.08 mg/mL and droperidol 0.05 mg/mL in 0.9% sodium chloride injection were stable for at least 360 hours when stored in PVC bags or glass bottles at 4°C and 25°C and protected from light.
Detecting strain in birefringent materials using spectral polarimetry
NASA Technical Reports Server (NTRS)
Garner, Harold R. (Inventor); Ragucci, Anthony J. (Inventor); Cisar, Alan J. (Inventor); Huebschman, Michael L. (Inventor)
2010-01-01
A method, computer program product and system for analyzing multispectral images from a plurality of regions of birefringent material, such as a polymer film, using polarized light and a corresponding polar analyzer to identify differential strain in the birefringent material. For example, the birefringement material may be low-density polyethylene (LDPE), high-density polyethylene (HDPE), polypropylene, polyethylene terephthalate (PET), polyvinyl chloride (PVC), polyvinylidene chloride, polyester, nylon, or cellophane film. Optionally, the method includes generating a real-time quantitative strain map.
Perilous plastics - are phthalate esters a risk for human reproductive health?
Phthalate diesters are high-production volume chemicals used to impart flexibility to polyvinyl chloride plastic (e.g. children’s toys and medical tubing) and are also found in other products (e.g. health and beauty products). Certain phthalate esters inhibit reproductive develop...
IMMUNE FUNCTION IN ADULT RATS EXPOSED TO DBT IN DRINKING WATER
Organotins are used commercially as agricultural pesticides, antifouling agents and stabilizers for polyvinyl chloride (PVC) pipe. Mono- and di-substituted methyl and butyltins, used in PVC pipe production, are of concern to the USEPA as they leach from supply pipes into drinking...
IMMUNE FUNCTION IN RATS DEVELOPMENTALLY EXPOSED TO DIBUTYLTIN DICHLORIDE
Organotins are used commercially as pesticides, antifouling agents and stabilizers for polyvinyl chloride (PVC) pipe. Mono- and di-substituted methyl and butyltins, used in PVC pipe production, are of concern to the USEPA as they leach from supply pipes into drinking water and ha...
THE DEVELOPMENTAL IMMUNOTOXICITY OF DIBUTYLTIN DICHLORIDE IN SPRAGUE-DAWLEY RATS
Methyl- and butyltin compounds used as stabilizers in polyvinyl chloride (PVC) pipe production are of concern as they leach from supply pipes into drinking water and have been associated with multisystem toxicity. This study assessed immune function in Sprague-Dawley (CD) rats d...
Perilous plasticizers - are phthalate esters a risk for human reproductive health?
Phthalate diesters are high-production volume chemicals used to impart flexibility to polyvinyl chloride plastic (e.g. children’s toys and medical tubing) as well as other products (e.g. health and beauty products). Certain phthalate esters inhibit reproductive development in la...
NASA Astrophysics Data System (ADS)
Zhang, Yanjuan; Gan, Tao; Li, Qian; Su, Jianmei; Lin, Ye; Wei, Yongzuo; Huang, Zuqiang; Yang, Mei
2014-09-01
Cassava stillage residue (CSR), a kind of agro-industrial plant fiber, was modified by coupling agent (CA), mechanical activation (MA), and MA-assisted CA (MACA) surface treatments, respectively. The untreated and different surface treated CSRs were used to prepare plant fibers/polymer composites (PFPC) with poly(vinyl chloride) (PVC) as polymer matrix, and the properties of these CSR/PVC composites were compared. Surface treated CSR/PVC composites possessed better mechanical properties, water resistance and dimensional stability compared with the untreated CSR/PVC composite, attributing to the improvement of interfacial properties between CSR and PVC matrix. MACA-treated CSR was the best reinforcement among four types of CSRs (untreated, MA-treated, CA-treated, and MACA-treated CSRs) because MACA treatment led to the significant improvement of dispersion, interfacial adhesion and compatibility between CSR and PVC. MACA treatment could be considered as an effective and green method for enhancing reinforcement efficiency of plant fibers and the properties of PFPC.
NASA Astrophysics Data System (ADS)
Ali, Z. I.; Said, Hossam M.; Ali, H. E.
2006-01-01
Films of poly(vinyl alcohol) (PVA) composites with triphenyl tetrazolium chloride (TTC) dye were prepared and exposed to various radiation doses delivered by accelerated electrons. The results showed that at a low dose of 50 kGy, the colour difference (Δ E*) of PVA/TTC films was increased by ˜10 times of the initial value. However, the change in colour differences did not go systematically with increasing the TTC content, in which the composite with 1.5 wt% displayed higher value than that with 3.5 wt%. The differential scanning calorimetry (DSC) showed that the presence of the TTC dye caused a depression in the melting point ( Tm) and heat of fusion (Δ Hf) of the PVA bulk polymer. However, the thermogravimetric analysis (TGA) showed that the presence of the TTC dye improved the thermal stability of PVA. Also, the tensile strength at break of PVA/TTC composites was improved after electron beam irradiation.
Testicular cancer and occupational exposure to polyvinyl chloride plastics: a case-control study.
Hardell, Lennart; Malmqvist, Nils; Ohlson, Carl-Göran; Westberg, Håkan; Eriksson, Mikael
2004-04-10
Exposure to polyvinyl chloride (PVC) plastics as a risk factor for testicular cancer was investigated. In total, 981 cases who were 20-75 years old and had reported to the Swedish Cancer Registry during 1993-1997 were included. One matched control from the population registry was used. Exposure was assessed by a questionnaire that was supplemented over the phone. Furthermore, an occupational hygienist qualified all exposures. In all, 791 matched pairs completed the questionnaire. Overall exposure to PVC plastics gave the odds ratio (OR)=1.35, 95% confidence interval (CI)=1.06-1.71, increasing with >10 year latency period to OR=1.45, 95% CI=1.06-1.98. No dose-response relationships were found but rather an inverse relationship with the highest odds ratios in the lowest exposure category. In conclusion, no clear association with testicular cancer and exposure to PVC could be found in our study in contrast to a previous observation. Copyright 2004 Wiley-Liss, Inc.
Case report of occupational asthma induced by polyvinyl chloride and nickel.
Song, Ga-Won; Ban, Ga-Young; Nam, Young-Hee; Park, Hae-Sim; Ye, Young-Min
2013-10-01
Polyvinyl chloride (PVC) is a widely used chemical for production of plastics. However occupational asthma (OA) caused by PVC has been reported only rarely. We report a 34-yr-old male wallpaper factory worker with OA due to PVC and nickel (Ni) whose job was mixing PVC with plasticizers. He visited the emergency room due to an asthma attack with moderate airflow obstruction and markedly increased sputum eosinophil numbers. A methacholine challenge test was positive (PC20 2.5 mg/mL). Bronchoprovocation tests with both PVC and Ni showed early and late asthmatic responses, respectively. Moreover, the fractional concentration of exhaled nitric oxide (FeNO) was increased after challenge with PVC. To our knowledge, this is the first case of OA in Korea induced by exposure to both PVC and Ni. We suggest that eosinophilic inflammation may be involved in the pathogenesis of PVC-induced OA and that FeNO monitoring can be used for its diagnosis.
Case Report of Occupational Asthma Induced by Polyvinyl Chloride and Nickel
Song, Ga-Won; Ban, Ga-Young; Nam, Young-Hee; Park, Hae-Sim
2013-01-01
Polyvinyl chloride (PVC) is a widely used chemical for production of plastics. However occupational asthma (OA) caused by PVC has been reported only rarely. We report a 34-yr-old male wallpaper factory worker with OA due to PVC and nickel (Ni) whose job was mixing PVC with plasticizers. He visited the emergency room due to an asthma attack with moderate airflow obstruction and markedly increased sputum eosinophil numbers. A methacholine challenge test was positive (PC20 2.5 mg/mL). Bronchoprovocation tests with both PVC and Ni showed early and late asthmatic responses, respectively. Moreover, the fractional concentration of exhaled nitric oxide (FeNO) was increased after challenge with PVC. To our knowledge, this is the first case of OA in Korea induced by exposure to both PVC and Ni. We suggest that eosinophilic inflammation may be involved in the pathogenesis of PVC-induced OA and that FeNO monitoring can be used for its diagnosis. PMID:24133363
Miniaci, Marco; Marzani, Alessandro; Testoni, Nicola; De Marchi, Luca
2015-02-01
In this work the existence of band gaps in a phononic polyvinyl chloride (PVC) plate with a square lattice of cross-like holes is numerically and experimentally investigated. First, a parametric analysis is carried out to find plate thickness and cross-like holes dimensions capable to nucleate complete band gaps. In this analysis the band structures of the unitary cell in the first Brillouin zone are computed by exploiting the Bloch-Floquet theorem. Next, time transient finite element analyses are performed to highlight the shielding effect of a finite dimension phononic region, formed by unitary cells arranged into four concentric square rings, on the propagation of guided waves. Finally, ultrasonic experimental tests in pitch-catch configuration across the phononic region, machined on a PVC plate, are executed and analyzed. Very good agreement between numerical and experimental results are found confirming the existence of the predicted band gaps. Copyright © 2014 Elsevier B.V. All rights reserved.
ACCUMULATION OF DIBUTYLTIN IN HUMAN NATURAL KILLER CELLS
NK cells are a subset of lymphocytes capable of killing tumor cells, virally infected cells and antibody coated cells. Dibutyltin dichloride (DBT) is a butyltin that has been used as a stabilizer in polyvinyl chloride (PVC) plastics and also as a deworming product in poultry. DBT...
URINARY METABOLITES OF DI-N-OCTYL PHTHALATE IN RATS
Di-n-octyl phthalate (DnOP) is a plasticizer used in polyvinyl chloride plastics, cellulose esters, and polystyrene resins. The metabolism of DnOP results in the hydrolysis of one ester linkage to produce mono-n-octyl phthalate (MnOP), which subsequently metabolizes to form oxida...
Effects of Prenatal Exposure to Phthalates
ERIC Educational Resources Information Center
Johnson, Laurie A.
2012-01-01
The purpose of this review of literature is to examine the association of phthalate exposure with development. Phthalates are chemical compounds used in poly-vinyl chloride, PVC; vinyl flooring, cosmetics, shampoo, air fresheners, soft plastic items, intravenous tubing, food packaging and wraps, textiles, paints, cleaning products and detergents.…
CORRELATION OF THE GLASS TRANSITION TEMPERATURE OF PLASTICIZED PVC USING A LATTICE FLUID MODEL
A model has been developed to describe the composition dependence of the glass transition temperature (Tg) of polyvinyl chloride (PVC) + plasticizer mixtures. The model is based on Sanchez-Lacombe equation of state and the Gibbs-Di Marzio criterion, which states that th...
NASA Technical Reports Server (NTRS)
Senturia, S. D.
1977-01-01
Polymer responses to a variety of smouldering sources, including cellulose, acrylic, urethane, polyvinyl chloride, and wool were investigated. A suitable trapping system for combustion products was developed and a charge flow transistor was fabricated to monitor the transverse or sheet resistance of a thin film.
Phthalates are plasticizers used to impart flexibility in products widely used by the general population, including polyvinyl chloride, plastic toys, and medical devices. Some phthalates act as anti-androgens, and prenatal or perinatal exposure to phthalates in laboratory animals...
Construction of Experimental Polyvinyl Chloride (PVC) Roofing.
1984-04-01
in. War II vintage; squash and handball courts were (13-mm) fiberboard, to comply with Sarnafil re- added in 1966. The entire structure is of wood con...squash and handball courts had a gravel surface. pendently, avoiding difficulties of trying to handle Figure 23 shows the building arrangements. two
The Analysis of Organotins in Polyvinyl Chloride Pipe and Their Diffusion into Water Over Time
Organotins are commonly used as thermal stabilizers in the manufacturing of PVC pipes, which are widely used in drinking water distribution systems. Additives, such as organotins, have been show to leach through PVC pipe into water. While tri-substituted organotin compounds hav...
Occupational asthma due to polyethylene shrink wrapping (paper wrapper's asthma).
Gannon, P F; Burge, P S; Benfield, G F
1992-01-01
Occupational asthma due to the pyrolysis products of polyvinyl chloride (PVC) produced by shrink wrapping processes has previously been reported. The first case of occupational asthma in a shrink wrap worker using a different plastic, polyethylene, is reported; the association was confirmed by specific bronchial provocation testing. PMID:1440477
Synthesis and application of a natural plasticizer based on cardanol for poly(vinyl chloride)
USDA-ARS?s Scientific Manuscript database
A natural plasticizer with multifunctional groups, similar in structure to phthalates, cardanol derivatives glycidyl ether (CGE) was synthesized from cardanol by a two-step modification process and characterized by FT-IR, 1-HNMR, and 13-CNMR. The resulting product was incorporated to PVC (CGE/PVC), ...
IMMUNE RESPONSES IN SPRAGUE-DAWLEY RATS EXPOSED TO DIBUTYLTIN DICHLORIDE IN DRINKING WATER AS ADULTS
Organotins are used commercially as agricultural pesticides, antifouling agents and stabilizers for
polyvinyl chloride (PVC) pipe. Mono- and di-substituted methyl and butyltins, used in PVC
pipe production, are of concern as they leach from supply pipes into drinkin...
Serum supplementation modulates the effects of dibutyltin on human natural killer cell function
NK cells are a subset of lymphocytes capable of killing tumor cells, virally infected cells and antibody coated cells. Dibutyltin dichloride (DBT) is an organotin used as a stabilizer in polyvinyl chloride (PVC) plastics and as a deworming product in poultry. DBT may leach from P...
ERIC Educational Resources Information Center
Bliss, Angela; Bell, Elizabeth; Spence, Lundie
2013-01-01
Oranges, flying disks, pool noodles, and polyvinyl chloride (PVC) pipe may seem like items discarded after a Rube Goldberg experiment, but in fact, these objects were used in teaching science, technology, engineering, and math (STEM). This article describes a project in which The Center of Ocean Sciences Education Excellence SouthEast (COSEE SE)…
Predicting the Migration Rate of Dialkyl Organotins from PVC Pipe into Water
Organotins (OTs) are additives widely used as thermal and light stabilizers in polyvinyl chloride (PVC) plastics. OTs can leach into water flowing through PVC pipes. This work examines the leaching rates of two neurotoxic OTs, dimethyl tin (DMT) and dibutyl tin (DBT), from PVC pi...
Installation Restoration Program. Phase I. Records Search. Vandenberg Air Force Base, California.
1984-12-01
acidity or alkalinity POL Petroleum, oils, and lubricants PVC Polyvinyl chloride plastic RCRA Resource Conservation and Recovery Act RP-1 Rocket propellant...multiplter: Subscore 3 K ?hvsical State ulriptier Waste Caracteristics Subscore 50 X 1 50 11-1. CS-I HAZARD ASSESSMENT RATING METHODOLOGY FORM (Continued
MONO-(3-CARBOXYPROPYL) PHTHALATE, A METABOLITE OF DI-N-OCTYL PHTHALATE
Di-n-octyl phthalate (DnOP) is found as a component of mixed C6–C10 linear-chain phthalates used as plasticizers in various polyvinyl chloride applications, including flooring and carpet tiles. Following exposure and absorption, DnOP is metabolized to its hydrolytic monoester, mo...
Kawakami, Tsuyoshi; Isama, Kazuo; Matsuoka, Atsuko
2011-01-01
The aim of this study was to determine the concentrations of six phthalic acid diesters (PAEs) [di(2-ethylhexyl) phthalate (DEHP), di-n-butyl phthalate (DBP), butyl benzyl phthalate (BBP), diisononyl phthalate (DINP), di-n-octyl phthalate (DNOP), and diisodecyl phthalate (DIDP)], two non-phthalic plasticizers [di(2-ethylhexyl) adipate (DEHA), 2,2,4-trimethyl-1,3-pentanediol diisobutylate (TMPDIB)], and mono 2-ethylhexyl phthalate(MEHP) in polyvinyl chloride (PVC) household products that children often places in their mouths and/or contact with their skin (41 products, 47 samples) in Japan. The detection frequencies of the studied compounds were as follows: DEHP (79 %), DINP-2 (13 %), DINP-1 (11 %), DBP (8.5 %), DEHA (8.5 %), DIDP (4.3 %), and DNOP (2.1 %). Concentrations of these compounds ranged from 0.021 % to 48 %. BBP and TMPDIB were not detected in the all samples. Most samples contained DEHP and DINP at high concentrations over 0.1 %. High concentrations of PAEs were detected in PVC household products that appear appealing to children and can possibly be licked and chewed by them. Di(2-ethylhexyl) terephtalete, diisononyl 1,2-cyclohexanedicarboxylic acid, acetyl tributyl citrate, and di(2-ethylhexyl) 4-cyclohexene-1,2-dicarboxylate used as substitute plasticizers were also detected in several samples. MEHP was present in 70 % of the samples, with concentrations ranging from trace amounts to 140 μg/g. The ratios of MEHP against DEHP were 6.2 × 10(-4) to 1.6 × 10(-1) %. MEHP in the household products investigated in this study was most probably an impurity in DEHP. The high concentrations of PAEs detected in products that children often place in their mouth reveal the importance of replacing plasticizers in common household products, and not just children's toys, with safer alternatives.
Eiden, Céline; Philibert, Laurent; Bekhtari, Khedidja; Poujol, Sylvain; Malosse, Francoise; Pinguet, Frédéric
2009-11-01
The physicochemical stability of extemporaneous dilutions of oxaliplatin in 5% dextrose injection stored in polyvinyl chloride (PVC), polypropylene, and polyethylene infusion bags was studied. Oxaliplatin 100 mg/20 mL concentrated solution was diluted in 100 mL of 5% dextrose injection in PVC, polypropylene, and polyethylene infusion bags to produce nominal oxaliplatin concentrations of 0.2 and 1.3 mg/mL. The filled bags were stored for 14 days at 20 degrees C and protected from light, at 20 degrees C under normal fluorescent light, and at 4 degrees C. A 1-mL sample was removed from each bag at time 0 and at 24, 48, 72, 120, 168, and 336 hours. The samples were visually inspected for color and clarity, and the pH values of the solutions were measured. High-performance liquid chromatography was used to assay oxaliplatin concentration. Bacterial contamination was assessed on study day 14 after incubation in trypticase soy solution for three days at 37 degrees C. Solutions of oxaliplatin 0.2 and 1.3 mg/mL in 5% dextrose injection were stable in the three container types for at least 14 days at both 4 degrees C and 20 degrees C without regard to light exposure. No color change was detected during the storage period, and pH values remained stable. No microbial contamination was detected in any samples over the study period. Oxaliplatin solutions diluted in 5% dextrose injection to 0.2 and 1.3 mg/mL were stable in PVC and PVC-free infusion bags for at least 14 days at both 4 degrees C and 20 degrees C without regard to light exposure.
Handa, Hitesh; Brisbois, Elizabeth J.; Major, Terry C.; Refahiyat, Lahdan; Amoako, Kagya A.; Annich, Gail M.; Bartlett, Robert H.; Meyerhoff, Mark E.
2013-01-01
Nitric oxide (NO) is an endogenous vasodilator as well as natural inhibitor of platelet adhesion and activation that can be released from a NO donor species, such as diazeniumdiolated dibutylhexanediamine (DBHD/N2O2) within a polymer coating. In this study, various Food and Drug Administration approved poly(lactic-co-glycolic acid) (PLGA) species were evaluated as additives to promote a prolonged NO release from DBHD/N2O2 within a plasticized poly(vinyl chloride) (PVC) matrix. When using an ester-capped PLGA additive with a slow hydrolysis time, the resulting coatings continuously release between 7–18×10-10 mol cm-2 min-1 NO for 14 d at 37°C in PBS buffer. The corresponding pH changes within the polymer films were visualized using pH sensitive indicators and are shown to correlate with the extended NO release pattern. The optimal combined diazeniumdiolate/PLGA-doped NO release (NOrel) PVC coating was evaluated in vitro and its effect on the hemodynamics was also studied within a 4 h in vivo extracorporeal circulation (ECC) rabbit model of thrombogenicity. Four out of 7 control circuits clotted within 3 h, whereas all the NOrel coated circuits were patent after 4 h. Platelet counts on the NOrel ECC were preserved (79 ± 11% compared to 54 ± 6% controls). The NOrel coatings showed a significant decrease in the thrombus area as compared to the controls. Results suggest that by using ester-capped PLGAs as additives to a conventional plasticized PVC material containing a lipophilic diazeniumdiolates, the NO release can be prolonged for up to 2 weeks by controlling the pH within the organic phase of the coating. PMID:23914297
Carbon film electrodes for super capacitor applications
Tan, Ming X.
1999-01-01
A microporous carbon film for use as electrodes in energy strorage devices is disclosed, which is made by the process comprising the steps of: (1) heating a polymer film material consisting essentially of a copolymer of polyvinylidene chloride and polyvinyl chloride in an inert atmosphere to form a carbon film; and (2) activating said carbon film to form said microporous carbon film having a density between about 0.7 g/cm.sup.2 and 1 g/cm.sup.2 and a gravimetric capacitance of about between 120 F/g and 315 F/g.
Polyvinyl alcohol battery separator containing inert filler. [alkaline batteries
NASA Technical Reports Server (NTRS)
Sheibley, D. W.; Hsu, L. C.; Manzo, M. A. (Inventor)
1981-01-01
A cross-linked polyvinyl alcohol battery separator is disclosed. A particulate filler, inert to alkaline electrolyte of an alkaline battery, is incorporated in the separator in an amount of 1-20% by weight, based on the weight of the polyvinyl alcohol, and is dispersed throughout the product. Incorporation of the filler enhances performance and increases cycle life of alkaline batteries when compared with batteries containing a similar separator not containing filler. Suitable fillers include titanates, silicates, zirconates, aluminates, wood floor, lignin, and titania. Particle size is not greater than about 50 microns.
Evaluation of Pad 18 Spent Mercury Gold Trap Stainless Steel Container Failure
DOE Office of Scientific and Technical Information (OSTI.GOV)
Skidmore, E.
Failure of the Pad 18 spent mercury gold trap stainless steel waste container is principally attributed to corrosion induced by degradation of plasticized polyvinyl chloride (pPVC) waste packaging material. Dehydrochlorination of pPVC polymer by thermal and/or radiolytic degradation is well-known to evolve HCl gas, which is highly corrosive to stainless steel and other metals in the presence of moisture. Degradation of the pPVC packaging material was likely caused by radiolysis in the presence of tritium gas within the waste container, though other degradation mechanisms (aging, thermo-oxidation, plasticizer migration) over 30 years storage may have contributed. Corrosion was also likely enhancedmore » by the crevice in the container weld design, and may have been enhanced by the presence of tritiated water. Similar non-failed spent mercury gold trap waste containers did not show radiographic evidence of plastic packaging or trapped free liquid within the container. Therefore, those containers are not expected to exhibit similar failures. Halogenated polymers such as pPVC subject to degradation can evolve halide gases such as HCl, which is corrosive in the presence of moisture and can generate pressure in sealed systems.« less
Hexamoll DINCH plasticised PVC containers for the storage of platelets
Nair, C. S. Bhaskaran; Vidya, R.; Ashalatha, P. M.
2011-01-01
Introduction: Containers for the storage of platelets are made using polyvinyl chloride plasticised with di, (2-ethyl hexyl) phthalate, n-butyryl, tri (n-hexyl) citrate and tri (2-ethyl hexyl) mellitate or using special poly olefins without plasticiser. Of these, the first two have disadvantages such as plasticiser leaching and impairment of platelet function. Polyolefin bags cannot be HF welded or steam sterilized. Mellitate plasticised bags can store platelets well for five days but they are not completely phthalate free. Research and Development: We have developed a new generation of containers made of PVC plasticised with the non DEHP, non aromatic plasticiser,1,2- Cyclohexanedicarboxylic acid, diisononyl ester (Hexamoll DINCH) which can store platelets without loss of function for at least six days. Observation: The present studies show that DINCH plasticised PVC bags (TPL-167) are well suited for the storage of platelet concentrates for more than five days. Conclusion: The present studies show that the PVC plasticised with the non phthalate, non aromatic, non toxic plasticiser DINCH is a viable alternative to other existing containers for the storage of platelets for more than five days. PMID:21572709
Code of Federal Regulations, 2012 CFR
2012-07-01
... Pollutant Emissions for Polyvinyl Chloride and Copolymers Production Testing and Compliance Requirements... organic compounds concentration (in parts per million by volume) as methane from the air stripping testing... compounds concentration (as methane) in the stripping gas of 3.9 parts per million by volume. (2) If you...
Code of Federal Regulations, 2013 CFR
2013-07-01
... Pollutant Emissions for Polyvinyl Chloride and Copolymers Production Testing and Compliance Requirements... organic compounds concentration (in parts per million by volume) as methane from the air stripping testing... compounds concentration (as methane) in the stripping gas of 3.9 parts per million by volume. (2) If you...
Code of Federal Regulations, 2014 CFR
2014-07-01
... Pollutant Emissions for Polyvinyl Chloride and Copolymers Production Testing and Compliance Requirements... organic compounds concentration (in parts per million by volume) as methane from the air stripping testing... compounds concentration (as methane) in the stripping gas of 3.9 parts per million by volume. (2) If you...
USDA-ARS?s Scientific Manuscript database
A novel plasticizer, epoxidized cardanol diethyl phosphate (ECEP), based on cardanol was synthesized. Chemical structure of ECEP was characterized by fourier transform infrared (FTIR), 1H-nuclear magnetic resonance(1H NMR) and 13C-nuclear magnetic resonance(13C NMR) spectroscopy. Effects of ECEP sub...
Lead and Cadmium in Vinyl Children's Products. A Greenpeace Expose.
ERIC Educational Resources Information Center
Di Gangi, Joseph
Polyvinyl chloride (vinyl or PVC) is a substance widely used in children's products. Because children in contact with these products may ingest substantial quantities of potentially harmful chemicals during normal play, especially when they chew on the product, this Greenpeace study examined the levels of lead and cadmium in a variety of consumer…
Direct Colony Baiting of Termite Colonies: A Tool for Ecological Studies
Don McG Ewart
1991-01-01
The benefits of direct colony baiting are described: bait substrates enclosed in polyvinyl chloride tubes are applied in direct contact with the galleries of the termite nest. Attention of researchers is drawn to the potential of this method for species other than the mound-building Coptotermes 1acteus. \\t
Imidacloprid mobility and logevity in soil columns at a termiticidal application rate
Chris J. Peterson
2007-01-01
The mobility, longevity and termiticidal activity of imidacloprid (Premiseï 2 termiticide; BayerEnvironmental Sciences) at the termiticidal labeled rate for perimeter treatment were tested in vegetated and non-vegetated soil columns in two tests: in cone plots and in polyvinyl chloride (PVC) pipes. Imidacloprid content in the...
49 CFR 179.201-3 - Lined tanks.
Code of Federal Regulations, 2010 CFR
2010-10-01
... Specifications for Non-Pressure Tank Car Tanks (Classes DOT-111AW and 115AW) § 179.201-3 Lined tanks. (a) Rubber... the service temperatures. (b) Before a tank car tank is lined with rubber, or other rubber compound, a... suitable for the service temperatures. (f) Polyvinyl chloride lined tanks. Tank car tanks or each...
Ototraumatic Effects of Hard Rock Music
Reddell, Rayford C.; Lebo, Charles P.
1972-01-01
Temporary and permanent shifts in auditory thresholds were found in 43 hard rock musicians and temporary shifts were also observed in some listeners. The threshold shifts involved all of the conventional puretone test frequencies. Custom-fitted polyvinyl chloride ear protectors were found to be effective in prevention of these noise-induced hearing losses. PMID:5008499
Abstract
Organotins are used commercially as pesticides, antifouling agents and stabilizers for polyvinyl chloride (PVC) pipe. Mono- and di-substituted butyltins, used in PVC pipe production, are of concern to the U.S. EPA because they leach from supply pipes into drinkin...
Organotins can be classified into a broad class of compounds referred to as endocrine disruptors and are presently being used in many applications such as UV stabilizers in polyvinyl chloride (PVC) pipes, antifoulants in marine paints, and as fungicides to name a few. The organo...
Three different polyvinyl chloride (PVC) pipe types were subjected to de-ionized water exposures over the course of at least 180 days. Water exposed to the pipe was analyzed for organotin speciation and concentration. Organotin concentrations were the highest during the first 1-5...
Several of the phthalate esters (widely used as plasticizers of polyvinyl chloride and other applications) have been shown to inhibit fetal testicular testosterone (T) production and Insl3 mRNA in the laboratory rat. The current study was designed to define the dose response of 7...
ERIC Educational Resources Information Center
LaFratta, Christopher N.; Huh, Sun Phill; Mallillin, Allistair C.; Riviello, Peter J.; Walt, David R.
2010-01-01
We describe an inexpensive hand-held fluorescence imager (low-magnification microscope), constructed from poly(vinyl chloride) pipe and other inexpensive components for use as a teaching tool to understand the principles of fluorescence detection. Optical filters are used to select the excitation and emission wavelengths and can be easily…
Mallakpour, Shadpour; Darvishzadeh, Marzieh
2018-03-01
In this project, physicochemical properties of poly(vinyl chloride) (PVC) reinforced by ZnO nanoparticles (NPs) were studied. Firstly, ZnO NPs were modified with bovine serum albumin (BSA) as an organo-modifier and biocompatible substance through ultrasound irradiation as environmental friendly, low cost and rapid means. Nanocomposite (NC) films were prepared by loadings of various ratios of ZnO/BSA NPs (3, 6 and 9wt%) inside the PVC. Structural morphology and physical properties of the ZnO-BSA NPs and NC films were investigated via Fourier transform infrared spectroscopy, X-ray diffraction, thermogravimetric analysis (TGA), transmission electron microscopy and field emission scanning electron microscopy. According to the obtained information from the TGA, an increase in the thermal stability can be clearly observed. Also the results of contact angle analysis indicated with increasing percent of ZnO/BSA NPs into PVC the hydrophilic behaviors of NCs were increased. Copyright © 2017 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Jung, Chan-Hee; Sohn, Joon-Yong; Kim, Hyo-Sub; Hwang, In-Tae; Lee, Hong-Joon; Shin, Junhwa; Choi, Jae-Hak
2018-05-01
In this work, we demonstrated that carbon nanosheet (CNS) can easily be produced by a room-temperature, solid-state proton irradiation-induced clustering of poly(vinyl chloride) (PVC) films followed by carbonization. The results of the optical, chemical, and structural analyses revealed that oxidized and sp2-hybridized carbon clusters were effectively created in the PVC thin film by combined dehydrochlorination and inter-coupling reactions during proton irradiation. This was further converted to pseudo-hexagonally-structured nano-crystalline CNS with 2-D symmetry and metallic transporting character by high-temperature treatment. As a result, the CNS exhibited a very high electrical conductivity (587 S/cm) without a significant change in their thickness, a low surface roughness (0.36 nm), and a high work function (5.11 eV). These findings demonstrate that the radiation-based approach opens new avenues for the design and development of 2-D CNS as a graphene allotrope for the application of electronic devices, including field-effect transistors, electric heating devices, biosensors, supercapacitors, and fuel cells.
Physical and chemical basics of modification of poly(vinyl chloride) by means of polyisocyanate
NASA Astrophysics Data System (ADS)
Islamov, Anvar; Fakhrutdinova, Venera; Abdrakhmanova, Lyailya
2016-01-01
This research presents data relating to polyvinyl chloride (PVC) modification by means of reactive oligomer and measures technological, physical and mechanical properties of the modified composites. Polyisocyanate (PIC) has been chosen as the modifying reactive oligomer. It has been shown that insertion of the oligomer has a double effect on PVC. Primarily, PIC produces a plasticizing effect on PVC and in particular leads to an increase in thermal stability and melt flow index at the stage of processing. In addition, the molded PVC composites possess higher strength properties and lower deformability when exposed to temperature because of chemical transformations of PIC in polymer matrix and, as the result, the formation of cross-linked systems takes place. In this case, semi-interpenetrating structures are formed based on cross-linked products of PIC chemical transformations homogeneously distributed in the PVC matrix. It has been determined by means of IR-spectroscopy that the basic products of PIC curing are compounds with urea and biuret groups which leads to modifying effect on PVC especially: increase in strength, thermal and mechanical properties, and chemical resistance.
Investigation of the source of residual phthalate in sundried salt.
Kim, Jin Hyo; Lee, Jin Hwan; Kim, So-Young
2014-03-01
Phthalate contamination in sundried salt has recently garnered interest in Korea. Phthalate concentrations were investigated in Korean sundried salts, source waters, and aqueous extracts from polyvinyl chloride materials used in salt ponds. Preliminary screening results for phthalates in Korean sundried salts revealed that only di(2-ethylhexyl)phthalate (DEHP) was over the limit of detection, with an 8.6% detection rate, and the concentration ranged from below the limit of detection to 0.189 mg/kg. The tolerable daily intake contribution ratio of the salt was calculated to be only 0.001%. Residual phthalates were below 0.026 mg/liter in source water, and the aqueous extracted di-n-butylphthalate, benzylbutylphthalate, and DEHP, which are considered endocrine disruptors, were below 0.029 mg/kg as derived from the polyvinyl chloride materials in salt ponds. The transfer ratios of the six phthalates from seawater to sundried salts were investigated; transfer ratio was correlated with vapor pressure (r(2) = 0.9875). Thus, di-n-butylphthalate, benzylbutylphthalate, DEHP, and di-n-octylphthalate can be considered highly likely residual pollutants in some consumer salts.
Xing, Yuanna; Lin, Zhihui; Feng, Anhong; Wang, Xin; Gong, Yemeng; Chen, Zeyong
2015-02-01
A novel method was established to determine short chain chlorinated paraffins (SC-CPs) in polyvinyl chloride (PVC) plastics by gas chromatography-negative chemical ion/mass spectrometry (GC-NCI/MS). Ultrasonic extraction was used to extract SCCPs from PVC plastics. The optimal extraction time was 1.5 h, and concentrated sulfuric acid was adopted to purify the extracted solution. Finally, SCCPs in a sample were detected by GC-NCI/MS at 160 C and with methane reagent gas at 1. 5 mL/min. This method was not influenced by medium chain chlorinated paraffins (MCCPs) in the sample, and accurate quantitation was made for SCCPs. Twelve batches of samples were analyzed and SCCPs were detected in each batch with the contents from 0. 3 x 10(2)mg/kg to 3. 5 x 10(4)mg/kg. With respect to European limitation of SC-CPs (1%), four batches of samples did not comply with the European regulation, and they accounted for 33. 3%. Obviously, high SCCPs risk was presented in PVC plastics.
Wang, Jianchao; Wang, Hui; Wang, Chongqing; Zhang, Lingling; Wang, Tao; Zheng, Long
2017-11-01
A novel method, calcium hypochlorite (CHC) treatment, was proposed for separation of hazardous poly(vinyl chloride) (PVC) plastic from mixed plastic wastes (MPWs) by froth flotation. Flotation behavior of single plastic indicates that PVC can be separated from poly(ethylene terephthalate) (PET), poly(acrylonitrile-co-butadiene-co-styrene) (ABS), polystyrene (PS), polycarbonate (PC) and poly(methyl methacrylate) (PMMA) by froth flotation combined with CHC treatment. Mechanism of CHC treatment was examined by contact angle measurement, scanning electron microscopy, Fourier transform infrared and X-ray photoelectron spectroscopy. Under the optimum conditions, separation of PVC from binary plastics with different particle sizes is achieved efficiently. The purity of PC, ABS, PMMA, PS and PET is greater than 96.8%, 98.5%, 98.8%, 97.4% and 96.3%, respectively. Separation of PVC from multi-plastics was further conducted by two-stage flotation. PVC can be separated efficiently from MPWs with residue content of 0.37%. Additionally, reusing CHC solution is practical. This work indicates that separation of hazardous PVC from MPWs is effective by froth flotation. Copyright © 2017 Elsevier Ltd. All rights reserved.
Spirou, Gloria M; Mandelis, Andreas; Vitkin, I Alex; Whelan, William M
2008-05-10
Photoacoustic (more precisely, photothermoacoustic) signals generated by the absorption of photons can be related to the incident laser fluence rate. The dependence of frequency domain photoacoustic (FD-PA) signals on the optical absorption coefficient (micro(a)) and the effective attenuation coefficient (micro(eff)) of a turbid medium [polyvinyl chloride-plastisol (PVCP)] with tissuelike optical properties was measured, and empirical relationships between these optical properties and the photoacoustic (PA) signal amplitude and the laser fluence rate were derived for the water (PVCP system with and without optical scatterers). The measured relationships between these sample optical properties and the PA signal amplitude were found to be linear, consistent with FD-PA theory: micro(a)=a(A/Phi)-b and micro(eff)=c(A/Phi)+d, where Phi is the laser fluence, A is the FD-PA amplitude, and a, ...,d are empirical coefficients determined from the experiment using linear frequency-swept modulation and a lock-in heterodyne detection technique. This quantitative technique can easily be used to measure the optical properties of general turbid media using FD-PAs.
Golcs, Ádám; Horváth, Viola; Huszthy, Péter; Tóth, Tünde
2018-05-03
Lead is a particularly toxic heavy metal that is present above acceptable levels in the water of many countries. This article describes a quick detection method of lead(II) ions using a polyvinyl chloride (PVC)-based ion-selective membrane electrode containing an acridono-crown ether ionophore by potentiometry. The electrochemical cell exhibits a Nernstian response for lead(II) ions between the concentration range of 10 −4 to 10 −2 M, and can be used in the pH range of 4⁻7. The applicability of this sensor was verified by measuring a multicomponent aqueous sample. Under the given conditions, this electrode is suitable for the selective quantitative analysis of lead(II) ions in the presence of many additional metal ions.
Chick, Hope E; Hunter, Kathleen F; Moore, Katherine N
2013-02-01
To highlight the challenges faced in adjusting to intermittent catheterisation for families and children affected by spina bifida. Toileting is a particular issue for children with spina bifida resulting in difficulty emptying their bladder. Management of incomplete emptying is intermittent catheterisation, which is now part of routine clinical care. The physical benefits of intermittent catheterisation are critical to renal health, and significant attention has been paid to this; less attention has been given to the personal aspects for the family or older child. A descriptive study of satisfaction with two products for intermittent catheterisation: polyvinyl chloride and hydrophilic catheters based on data obtained from a randomised controlled trial on urinary tract infections in catheter users. At the end of each of the polyvinyl chloride and hydrophilic study arms, parents or older children completed a 'Satisfaction Questionnaire' and then participated in a follow-up interview. Data were analysed for emerging themes. Three themes emerged: adjustment, ease of use and self-reliance. Key findings include: increased independence and confidence of the child catheterising using the hydrophilic catheter, self-management strategies to successfully manipulate the slippery hydrophilic catheter and reasons for the lack of success, and identification of participants who preferred polyvinyl chloride catheters. Descriptive data revealed potential areas where a hydrophilic catheter could improve the lives of the family and child as well as noting the need for user choice in product selection. Listening to the stories of children and families increases the nurse's ability to act as a guide as families struggle to assist their children in reaching their potential. Incontinence has been demonstrated to be the cause of self-isolation potentially leading to a decreased sense of self-worth. Ambulatory care nurses play a large role in helping families find the routine and resources necessary to reduce the incidence of incontinence, in children with spina bifida. © 2012 Blackwell Publishing Ltd.
DOE Office of Scientific and Technical Information (OSTI.GOV)
None
1959-07-15
A description is given of laminated sheet, consisting of a first layer of absorbing and preferably fibrous material (e.g., filter or blotting paper, or felt), a second layer of adhesive, impermeable, and hydrophobic material (e.g., wax, bitumen, a polyvinyl or polyacrylic compound, or a polyhydrocarbon), and a third (and fourth) layer of rigid material more or less impermeable to liquids (e.g., metal (aluminum), polyvinyl chloride, polyethylene, or cardboard). These sheets can be used for covering laboratory tables and walls, for radiation protection (manufacture of clothes, etc.), or for packaging radioactive waste (manufacture of boxes, bags, etc.). (NPO)
NASA Astrophysics Data System (ADS)
Nishio, Takashi; Naka, Kensuke
2015-06-01
Photoinduced crystallization of calcium carbonate (CaCO3), which was based on the photodecarboxylation of ketoprofen (KP, 2-(3-benzoylphyenyl)propionic acid) under alkaline conditions of pH 8.4 and 10 was studied for preparation of CaCO3 composite particles in single-digit micrometer-sizes. In this method, a homogeneous solution comprising KP, calcium chloride, ammonia, and partially hydrolyzed poly(vinyl alcohol) (PVAPS, degree of saponification: 86.5-89.0 mol%) was used as a precursor solution and was exposed to ultraviolet (UV) irradiation for different time periods. After the UV irradiation for 50 min, calcite spheroids in single-digit micrometer-sizes were obtained as major products at pH 8.4. The obtained calcite spheroids contained organic components of about 10 wt%. The comparison of the characteristics of the CaCO3 obtained at pH 8.4 and 10 suggests that the nucleation and crystallization of both vaterite and calcite continuously took place in a moderated supersaturation owing to the CO2 hydration equilibrium as long as the photodecarboxylation of KP continued. Consequently, the aggregation-based crystal growth in the presence of PVAPS seemed to enable the formation of the spheroidal composites of calcite in single-digit micrometer-sizes.
Thermal degradation products from PVC film in food-wrapping operations.
Boettner, E A; Ball, G L
1980-07-01
Thermal degradation products of polyvinyl chloride (PVC) food-wrap films were studied under simulated supermarket conditons using a commercial wrapping machine with either a hot wire or a cool rod cutting device. A sampling hood was constructed around the wire/rod to confine and allow collection of thermal degradation products produced. Compounds analyzed and normal concentration ranges found included hydrogen chloride (1-10 micrograms per cut), plasticizer (1-50 micrograms per cut), benzene and toluene (each < 5-20 ng per cut), acrolein (25-150 ng per cut), and carbon monoxide (2-4 micrograms per cut) using the hot wire. Room air samples, collected during hot-wire cutting without the sampling hood, had < 0.25 ppm hydrogen chloride. Using the cool-rod cutting device hydrogen chloride, benzene, and toluene were not detected. Plasticizer was detected (25-86 micrograms per cut) using the cool rod.
USDA-ARS?s Scientific Manuscript database
Listeria monocytogenes can colonize a poultry processing or further processing plant as a resident in floor drains. Limiting growth and attachment to drain surfaces may help lessen the potential for cross contamination of product. The objective of this study was to compare a synthetic hydrogen per...
USDA-ARS?s Scientific Manuscript database
Polyvinyl chloride polymer (pvc) dispensers loaded with ethyl (E,Z)-2,4-decadienoate (pear ester) plus the sex pheromone, (E,E)-8,10-dodecadien-1-ol (codlemone) of codling moth, Cydia pomonella (L.), were compared with similar dispensers and a commercial dispenser (Isomate®-C Plus) loaded with codle...
Advances and challenges of wood polymer composites
Roger M. Rowell
2006-01-01
Wood flour and fiber have been blended with thermoplastic such as polyethylene, polypropylene, polylactic acid and polyvinyl chloride to form wood plastic composites (WPC). WPCs have seen a large growth in the United States in recent years mainly in the residential decking market with the removal of CCA treated wood decking from residential markets. While there are...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-04-17
.... EPA-HQ-OAR-2002-0037. All documents in the docket are listed on the http://www.regulations.gov Web... voluntary consensus standards VOC volatile organic compound WWW World Wide Web Organization of This Document. The following outline is provided to aid in locating information in this preamble. I. General...
Organotins are used commercially as pesticides, antifouling agents and stabilizers for polyvinyl chloride (PVC) pipe. Mono- and di-substituted methyl and butyltins, used in PVC pipe production, are of concern to the U.S. EPA as they leach from supply pipes into drinking water an...
O'Rourke, Michelle; Duffy, Noel; De Marco, Roland; Potter, Ian
2011-01-01
Electrochemical impedance spectroscopy (EIS) has been used to estimate the non-frequency dependent (static) dielectric constants of base polymers such as poly(vinyl chloride) (PVC), cellulose triacetate (CTA) and polystyrene (PS). Polymer inclusion membranes (PIMs) containing different amounts of PVC or CTA, along with the room temperature ionic liquid Aliquat 336 and plasticizers such as trisbutoxyethyl phosphate (TBEP), dioctyl sebecate (DOS) and 2-nitrophenyloctyl ether (NPOE) have been investigated. In this study, the complex and abstract method of EIS has been applied in a simple and easy to use way, so as to make the method accessible to membrane scientists and engineers who may not possess the detailed knowledge of electrochemistry and interfacial science needed for a rigorous interpretation of EIS results. The EIS data reported herein are internally consistent with a percolation threshold in the dielectric constant at high concentrations of Aliquat 336, which illustrates the suitability of the EIS technique since membrane percolation with ion exchangers is a well-known phenomenon. PMID:24957616
Datta, Pallab; Chatterjee, Jyotirmoy; Dhara, Santanu
2013-01-01
Polyvinyl alcohol (PVA) and polylactic acids (PLA) are biocompatible materials possessing some inherent contrasting limitations which have reduced the scope of their individual applicability. Specifically, overcoming strong hydrophobicity and introducing chemical groups for biofunctionalization are unmet challenges for PLA whilst chemical endeavors to render adequate aqueous stability and cell adhesion properties to PVA have not produced completely intended results. Objective of the present work is to explore synthesis of a graft polymer as an approach towards coupling biofunctional groups with PLA materials. In a two-step reaction, PPVA (phosphorylated polyvinyl alcohol or PVA pre-functionalized with phosphate) is esterified with lactic acid followed by polymerization into PLA in presence of stannous chloride as catalyst to obtain phosphorylated polyvinyl alcohol-graft-polylactic acid (PPVA-g-LA) copolymer. Product is characterized by nuclear magnetic resonance, X-ray diffraction, and thermogravimetric analysis. PPVA-g-LA shows an increase in uniaxial elongation compared to parent PPVA under condition of tensile loading. The graft copolymer also exhibits higher water contact angles compared to PPVA, but a more hydrophilic surface compared to PLA. Culture of MG-63 cells on solvent cast films of polymers demonstrates that PPVA-g-LA as a cell substrate can significantly (p < 0.05) improve proliferation and differentiation of cells compared to PPVA substrate whereas in comparison to PLA can significantly ameliorate osteoblast function of cultured cells. Overall, results illustrate the feasibility of PVA to act as a carrier for biofunctional agents to be coupled to lactic acid-based biomaterials with subsequent improvement in cell response on the polymers. In this attempt, it also affords materials with tunable surface or bulk properties of relevance for tissue engineering applications.
Kaiser, Jeanette; Krämer, Irene
2012-06-01
The aim of this study was to investigate the physicochemical stability of clofarabine (CAFdA) injection concentrate and ready-to-use CAFdA infusion solutions over a prolonged period of 28 days. To determine the stability of CAFdA infusion solutions, the injection concentrate (Evoltra®, 1 mg/mL, Genzyme) was diluted either with 0.9% sodium chloride or 5% glucose infusion solution. The resulting concentrations of 0.2 mg/mL or 0.6 mg/mL, respectively, were chosen to represent the lower and upper limit of the ordinary concentration range. Test solutions were stored under refrigeration (2-8°C) or at room temperature either light protected or exposed to light. CAFdA concentrations and pH values were determined at different time intervals throughout a 28-day storage period. Compatibility of diluted CAFdA infusion solutions (0.1-0.4 mg/mL) with different container materials (polyvinyl chloride (PVC), glass, and polypropylene/polyethylene (PP/PE)) was tested over a 48-h storage period. CAFdA concentrations were measured by a stability-indicating reversed phase high-performance liquid chromatography (HPLC) assay with ultraviolet detection. CAFdA injection concentrate and CAFdA infusion solutions remained physicochemically stable (>90% CAFdA) for 4 weeks. Results are independent of storage conditions, drug concentrations (0.2, 0.6, and 1.0 mg/mL) and diluents (0.9% sodium chloride, 5% glucose infusion solution). Adsorption of CAFdA to container material can be excluded. CAFdA injection concentrate and diluted infusion solutions in commonly used vehicles are stable for at least 28 days either refrigerated or at room temperature. Physicochemical stability favors pharmacy-based centralized preparation. Due to microbiological reasons, strict aseptic handling and storage of the products under refrigeration is recommended.
Yang, Si; Wo, Yaqi; Meyerhoff, Mark E.
2014-01-01
Cobalt(III) 5, 10, 15-tris(4-tert-butylphenyl) corrole with a triphenylphosphine axial ligand and rhodium(III) 5,10,15,20-tetra(p-tert-butylphenyl)porphyrin are incorporated into plasticized poly(vinyl chloride) films to fabricate nitrite-selective bulk optodes via absorbance measurements. The resulting films yield sensitive, fast and fully reversible response toward nitrite with significantly enhanced nitrite selectivity over other anions including lipophilic anions such as thiocyanate and perchlorate. The selectivity patterns differ greatly from the Hofmeister series based on anion lipophilicity and are consistent with selectivity obtained with potentiometric sensors based on the same ionophores. The optical nitrite sensors are shown to be useful for detecting rates of emission of nitric oxide (NO) from NO releasing polymers containing S-nitroso-N-acetyl-penicillamine. PMID:25150700
Electrospinning of PVC with natural rubber
NASA Astrophysics Data System (ADS)
Othman, Muhammad Hariz; Mohamed, Mahathir; Abdullah, Ibrahim
2013-11-01
Polyvinyl chloride (PVC) was mixed with natural rubbers which are liquid natural rubber (LNR), liquid epoxidised natural rubber (LENR) and liquid epoxidised natural rubber acrylate (LENRA) for a preparation of a fine non-woven fiber's mat. PVC and each natural rubbers(PVC:LENR, PVC:LNR and PVC:LENRA) were mixed based on ratio of 70:30. Electrospinning method was used to prepare the fiber. The results show that the spinnable concentration of PVC/ natural rubber/THF solution is 16 wt%. The morphology, diameter, structure and degradation temperature of electrospun fibers were investigated by scanning electron microscopy (SEM) and thermogravimetric analysis (TGA). SEM photos showed that the morphology and diameter of the fibers were mainly affected by the addition of natural rubber. TGA results suggested that PVC electrospun fiber has higher degradation temperature than those electrospun fibers that contain natural rubber.
Co-pyrolysis characteristics and kinetic analysis of organic food waste and plastic.
Tang, Yijing; Huang, Qunxing; Sun, Kai; Chi, Yong; Yan, Jianhua
2018-02-01
In this work, typical organic food waste (soybean protein (SP)) and typical chlorine enriched plastic waste (polyvinyl chloride (PVC)) were chosen as principal MSW components and their interaction during co-pyrolysis was investigated. Results indicate that the interaction accelerated the reaction during co-pyrolysis. The activation energies needed were 2-13% lower for the decomposition of mixture compared with linear calculation while the maximum reaction rates were 12-16% higher than calculation. In the fixed-bed experiments, interaction was observed to reduce the yield of tar by 2-69% and promote the yield of char by 13-39% compared with linear calculation. In addition, 2-6 times more heavy components and 61-93% less nitrogen-containing components were formed for tar derived from mixtures. Copyright © 2017 Elsevier Ltd. All rights reserved.
Air-Inflated Fabric Structures
2006-11-05
environmental exposure to ultraviolet rays, moisture, fire, chemicals, etc. Coating such as urethane, PVC (polyvinyl chloride), neoprene, EPDM (ethylene...tests on rubber -coated, plain-woven fabrics and established that the initial shear response was dominated by the coating and with increased shearing...Farboodmanesh, S., Chen, J., Mead, J. L., White, K., "Effect of Construction on Mechanical Behavior of Fabric Reinforced Rubber ," Rubber Division
Solid polymer electrolyte lithium batteries
Alamgir, M.; Abraham, K.M.
1993-10-12
This invention pertains to Lithium batteries using Li ion (Li[sup +]) conductive solid polymer electrolytes composed of solvates of Li salts immobilized in a solid organic polymer matrix. In particular, this invention relates to Li batteries using solid polymer electrolytes derived by immobilizing solvates formed between a Li salt and an aprotic organic solvent (or mixture of such solvents) in poly(vinyl chloride). 3 figures.
Solid polymer electrolyte lithium batteries
Alamgir, Mohamed; Abraham, Kuzhikalail M.
1993-01-01
This invention pertains to Lithium batteries using Li ion (Li.sup.+) conductive solid polymer electrolytes composed of solvates of Li salts immobilized in a solid organic polymer matrix. In particular, this invention relates to Li batteries using solid polymer electrolytes derived by immobilizing solvates formed between a Li salt and an aprotic organic solvent (or mixture of such solvents) in poly(vinyl chloride).
Specific adhesion model for bonding hot-melt polyamides to vinyl
Charles R. Frihart
2004-01-01
Hot-melt polyamides are an important market for the dimer acid made from the tall oil fatty acids liberated during the Kraft pulping process. These polyamides bond well to many substrates, but not to polyvinyl chloride (PVC), commonly called vinyl. Dimer-based polyamides made from secondary amines such as piperazine bond well to vinyl. No model for this unique adhesion...
USDA-ARS?s Scientific Manuscript database
An in vitro experiment was conducted to understand the nature of biofilm growth on polyvinyl chloride (PVC) surface when exposed to sub optimal quality microbial water (> 4 log10 cfu/ml) obtained from poultry drinking water source mimicking water in waterlines during the first week of poultry broodi...
NASA Astrophysics Data System (ADS)
Nouh, S. A.
Non isothermal studies were carried out using thermogravimetry (TG) and differential thermogravimetry (DTG) to obtain the activation energy of decomposition for chlorinated polyvinyl chloride (CPVC) before and after exposure to gamma doses at levels between 5.0 and 50.0 KGy. Thermal gravitational analysis (TGA) indicated that the CPVC polymer decomposes in one main breakdown stage and a decrease in activation energies was observed followed by an increase on increasing the gamma dose. The variation of melting temperatures with the gamma dose has been determined using differential thermal analysis (DTA). Also, mechanical and structural property studies were performed on all irradiated and non-irradiated CPVC samples using stress-strain relations and X-ray diffraction. The results indicated that the exposure to gamma doses at levels between 27.5 and 50 KGy leads to further enhancement of the thermal stability, tensile strength and isotropic character of the polymer samples due to the crosslinking phenomenon. This suggests that gamma radiation could be a suitable technique for producing a plastic material with enhanced properties that can be suitable for high temperature applications and might be a suitable candidate for dosimetric applications.
Zhong, Zhixiong; Li, Gongke; Luo, Zhibin; Liu, Zhe; Shao, Yijuan; He, Wanwen; Deng, Jianchao; Luo, Xingling
2015-08-12
A carboxylated graphene oxide/polyvinyl chloride (CGO/PVC) material was prepared as a sorbent for the selective extraction of sulphonamides from complex sample. After being dispersed in buffer solution, sample was transferred into the prefabricated solid-phase extraction (SPE) column, which integrated extraction and cleanup into one single-step. A multi-response optimization based on the Box-Behnken design was used to optimize factors affecting extraction efficiency. Compared with the commonly commercial sorbents including MCX, WCX and C18, CGO/PVC hybrid material had higher extraction selectivity and capacity to sulphonamides. The limits of detection and quantification for seven target compounds were in the range of 3.4-7.1 μg/L and 11.4-23.7 μg/L, respectively. The self-assembly SPE cartridge was successfully used to enrich seven analytes in anti-acne cosmetics prior to ion chromatography detection with good recoveries of 87.8-102.0% and relative standard deviations of 1.2-6.4%, implying that this method was suitable for routine analysis of cosmetics. Copyright © 2015 Elsevier B.V. All rights reserved.
Pressure loss in elbow pipes of unplasticized polyvinyl chloride.
Iwasaki, T; Ojima, J
1996-01-01
In the ductwork of local exhaust systems, 90 degrees elbow pipes (JIS K 6739) are commonly used to alter the direction of airflow; thus, are important components of polyvinyl chloride (PVC) ducts. Pressure loss in 90 degrees PVC elbow pipes was investigated by measuring static pressure, and the characteristics of airflow was determined. First, a linear decrease in static pressure was observed at points of the downstream side beyond a distance of 10 times the diameter (10d) from the flanged round opening of the smooth VU ducts (JIS K6741). The linear decrease was also observed at points of the downstream side located at distances of greater than 30d from the elbow pipe. Coefficients of loss in the PVC elbow pipes were found to be constant for the Reynolds numbers ranging from 3.38 x 10(4) to 5.96 x 10(5) for all diameters examined, and a chart of pressure loss was constructed with these coefficients. The coefficients of loss in PVC elbow pipes were not equivalent to those of metal stamped elbows for any R/d. However, the differences in the coefficients between the metal stamped elbow and the PVC elbow were smaller with larger R/d values.
Wang, Hongxing; Liu, Dong; Du, Pengcheng; Wei, Wenli; Wang, Qi; Liu, Peng
2017-11-15
The free-standing polyaniline (PANI)-based composite film electrodes were prepared with polyvinyl chloride (PVC) and the aniline modified PVC (PVC-An) films as flexible substrates for supercapacitors, via facile in-situ chemical oxidative polymerization of aniline, with conventional chemical oxidative polymerization or rapid-mixing chemical oxidative polymerization technique. Owing to the grafting of PANI from the PVC-An film as substrate and the suppression of the secondary growth of the primary PANI particles in the rapid-mixing chemical oxidative polymerization, the PVC-g-PANI-2 composite film with loose surface possessed better comprehensive performance, accompanying the high specific capacitance (645.3F/g at a current density of 1A/g), good rate capacitance (retaining 63.2% of original value at a current density of 10A/g and 52.0% at a scan rate of 100mV/s), good cycle stability (retaining 83.1% after 1000 cycles) and the improved internal resistance. Besides its excellent flexibility, it could retain 61.2% of its original specific capacitance under the stress of 8.66MPa for 1h, demonstrating a good tensile-resistance. Copyright © 2017 Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bai, Ying; Wang, Zhen; Wu, Chuan
2015-02-27
Two types of hard carbon materials were synthesized through direct pyrolysis of commercial polyvinyl chloride (PVC) particles and pyrolysis of PVC nanofibers at 600-800 degrees C, respectively, where the nanofibers were prepared by an electrospinning PVC precursors method. These as-prepared hard carbon samples were used as anode materials for Na-ion batteries. The hard carbon obtained from PVC nanofibers achieved a high reversible capacity of 271 mAh/g and an initial Coulombic efficiency of 69.9%, which were much superior to the one from commercial PVC, namely, a reversible capacity of 206 mAh/g and an initial Coulombic efficiency of 60.9%. In addition, themore » hard carbon originated from the PVC nanofibers exhibited good cycling stability and rate performance: the initial discharge capacities were 389, 228, 194, 178, 147 mAh/g at the current density of 12, 24, 60, 120, and 240 mA/g, respectively, retaining 211 mAh/g after 150 cycles. Such excellent cycle performance, high reversible capacity, and good rate capability enabled this hard carbon to be a promising candidate as anode material for Na-ion battery application.« less
NASA Astrophysics Data System (ADS)
Rodríguez-Fernández, Oliverio S.; Rodríguez-Calzadíaz, C. A.; Yáñez-Flores, Isaura G.; Montemayor, Sagrario M.
In this work two kind of materials: (1) grafted, cross-linked and plasticized poly(vinyl chloride) (PVC) "plastic films" and (2) magnetic plastic films "magneto-polymeric nanocomposites" were prepared. Precursor solutions or "plastisols" used to obtain the plastic films were obtained by mixing PVC (emulsion grade) as polymeric matrix, di(2-ethylhexyl)phthalate (DOP) as plasticizer, a thermal stabilizer based in Ca/Zn salts, and a cross-linking agent, 3-mercaptopropyltrimethoxysilane (MTMS) or 3-aminopropyltriethoxysilane (ATES), at several concentrations. Flexible films were obtained from the plastisols using static casting. The stress-strain behavior and the gel content (determined by Soxhlet extraction with boiling THF) of the flexible films were measured in order to evaluate the effect of the cross-linking agent and their content on the degree of cross-linking. The magneto-polymeric nanocomposites were obtained by mixing the optimum composition of the plastisols (analyzed previously) with magnetite (Fe 3O 4)-based ferrofluid and DOP. Later, flexible films were obtained by static casting of the plastisol/ferrofluid systems. The magnetic films were characterized by the above-mentioned techniques and X-ray diffraction, vibrating sample magnetometry and thermogravimetrical analysis.
Bai, Ying; Wang, Zhen; Wu, Chuan; Xu, Rui; Wu, Feng; Liu, Yuanchang; Li, Hui; Li, Yu; Lu, Jun; Amine, Khalil
2015-03-11
Two types of hard carbon materials were synthesized through direct pyrolysis of commercial polyvinyl chloride (PVC) particles and pyrolysis of PVC nanofibers at 600-800 °C, respectively, where the nanofibers were prepared by an electrospinning PVC precursors method. These as-prepared hard carbon samples were used as anode materials for Na-ion batteries. The hard carbon obtained from PVC nanofibers achieved a high reversible capacity of 271 mAh/g and an initial Coulombic efficiency of 69.9%, which were much superior to the one from commercial PVC, namely, a reversible capacity of 206 mAh/g and an initial Coulombic efficiency of 60.9%. In addition, the hard carbon originated from the PVC nanofibers exhibited good cycling stability and rate performance: the initial discharge capacities were 389, 228, 194, 178, 147 mAh/g at the current density of 12, 24, 60, 120, and 240 mA/g, respectively, retaining 211 mAh/g after 150 cycles. Such excellent cycle performance, high reversible capacity, and good rate capability enabled this hard carbon to be a promising candidate as anode material for Na-ion battery application.
Chemically Modified Polyvinyl Chloride for Removal of Thionine Dye (Lauth’s Violet)
Silva, Cleuzilene V.; Royer, Betina; Rodrigues Filho, Guimes; Cerqueira, Daniel A.; Assunção, Rosana M. N.
2017-01-01
The chemical modification of hydrophobic polymer matrices is an alternative way to elchange their surface properties. The introduction of sulfonic groups in the polymer changes the surface properties such as adhesion, wettability, catalytic ability, and adsorption capacity. This work describes the production and application of chemically modified polyvinyl chloride (PVC) as adsorbent for dyes removal. Chemical modification of PVC was evaluated by infrared spectroscopy and elemental analysis, which indicated the presence of sulfonic groups on PVC. The chemically modified PVC (PVCDS) showed an ion exchange capacity of 1.03 mmol−1, and efficiently removed the thionine dye (Lauth’s violet) from aqueous solutions, reaching equilibrium in 30 min. The adsorption kinetics was better adjusted for a pseudo second order model. This result indicates that the adsorption of thionine onto PVCDS occurs by chemisorption. Among the models for the state of equilibrium, SIPS and Langmuir exhibited the best fit to the experimental results and PVCDS showed high adsorption capacities (370 mg−1). Thus, it is assumed that the system presents homogeneous characteristics to the distribution of active sites. The modification promoted the formation of surface characteristics favorable to the dye adsorption by the polymer. PMID:29137158
Farrah, S R; Erdos, G W
1991-06-01
Two procedures were used to modify gauze bandages, polyester sutures, silicone tubing, and polyvinyl chloride tubing. In one procedure, the materials were first modified by in situ precipitation of metallic hydroxides and then used to adsorb silver ions. In the second procedure, the materials were soaked in sodium pyrophosphate or sodium chloride, dried, and then soaked in silver nitrate. These procedures produced materials with silver deposited on the surface of the tubing and sutures and both on the surface and within the gauze fibers. The modified materials inhibited the growth of Pseudomonas aeruginosa. Escherichia coli, and Staphylococcus aureus in vitro.
Landfill Liners and Covers: Properties and Application to Army Landfills.
1984-06-01
polymers, TPE can be seamed by heat techniques. Materials such as thermoplastic EPDM and nitrile rubber /PVC blends are still being tested to determine their...such as polyethylene (PE), polyvinyl chloride (PVC), butyl rubber , ethylene propylene diene monomer ( EPDM ), chlorinated polyethylene (CPE), and others...chlorosulfonated polyethy- lene (CSPE), chlorinated polyethylene (CPE), butyl rubber , ethylene propylene S rubber ( EPDM ), neoprene, high-density polyethylene
Dual UV/thermally curable plastisols
DOE Office of Scientific and Technical Information (OSTI.GOV)
Morgan, C.R.
1983-10-01
Photoactive, thermally curable plastisol compositions are made by mixing a thermoplastic (preferably poly(vinyl chloride)), a (meth)acrylate, a thermal initiator, a photoinitiator, and a conventional plasticizer. A short exposure of these compositions to UV results in a tack-free skin cure. Heating after UV irradiation gives simultaneous crosslinking and fusion. These dual UV/thermally curable plastisols are useful as adhesives, sealants, encapsulants, and in many other applications.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Norsworthy, R.
A rating system was developed for several coating types used for underground pipeline systems. Consideration included soil stress, adhesion, surface preparation, cathodic protection (CP) shielding, CP requirements, handling and construction, repair, field joint system, bends and other components, and the application process. Polyethylene- and polyvinyl chloride-backed tapes, woven polyolefin geotextile fabric (WGF)-backed tapes, hot-applied tapes, petrolatum- and wax-based tapes, and shrink sleeves were evaluated. WGF-backed tapes had the highest rating.
Outplanting long tubes with the expandable stinger: A new treatment for riparian restoration
David E. Steinfeld; Thomas D. Landis; Dan Culley
2002-01-01
Long tubes are a new stock type developed specifically for restoration of challenging sites such as disturbed riparian areas. Constructed out of polyvinyl chloride plastic pipe, long tubes have a Vexar lining to promote good root growth and easier extraction. The expandable stinger is a new invention that was developed to outplant long tubes. The stinger is attached to...
ERIC Educational Resources Information Center
Burmeister, Mareike; Eilks, Ingo
2014-01-01
People use many different products made from plastics every day. But conventional plastics such as polyvinyl chloride (PVC) do not always have a good reputation in society at large. Bioplastics such as thermoplastic starch (TPS) promise to be better alternatives but are they really better than conventional plastics? This article presents a new…
Fujimori, Takashi; Itai, Takaaki; Goto, Akitoshi; Asante, Kwadwo A; Otsuka, Masanari; Takahashi, Shin; Tanabe, Shinsuke
2016-02-01
Open burning of electronic waste (e-waste) releases various metals and organohalogen compounds in the environment. Here we investigated the interplay of metals (Cu, Pb, Zn, Fe, Co, and Sr) and bromine (Br) in the formation of dioxin-related compounds (DRCs), including polychlorinated dibenzo-p-dioxins/furans (PCDD/Fs) and dioxin-like polychlorinated biphenyls (DL-PCBs), as well as non-regulated DRCs such as polybrominated dibenzo-p-dioxins/furans (PBDD/Fs) and their monobrominated PCDD/Fs in soils sampled from open burning e-waste sites at Agbogbloshie in Accra, Ghana. The predominant DRCs were PBDFs, PCDFs, PCDDs, and DL-PCBs. Statistical analyzes, X-ray absorption spectroscopy, and the PCDF/PCDD ratio suggested possible formation paths of PCDD/Fs and DL-PCBs by catalytic behaviors of copper chlorides (CuCl, CuCl2, and Cu2(OH)3Cl) and thermal breakdown of polyvinyl chloride. Predominant formation of brominated furans may be derived from electron transfer from intermediates of PBDE to copper, Cu(II) → Cu(I). Lead chloride also contributed to generate DRCs and may become highly bioaccessible through the open burning of e-waste. The main zinc species (ZnCl2 and ZnS) suggested a possible relationship to generate DRCs and specific zinc source such as tire burning. Cu, Pb, Zn, and Br contained in various e-wastes, wires/cables, plastics, and tires strongly influenced generation of many DRCs. Copyright © 2015 Elsevier Ltd. All rights reserved.
Electrospinning of PVC with natural rubber
DOE Office of Scientific and Technical Information (OSTI.GOV)
Othman, Muhammad Hariz; Abdullah, Ibrahim; Mohamed, Mahathir
Polyvinyl chloride (PVC) was mixed with natural rubbers which are liquid natural rubber (LNR), liquid epoxidised natural rubber (LENR) and liquid epoxidised natural rubber acrylate (LENRA) for a preparation of a fine non-woven fiber’s mat. PVC and each natural rubbers(PVC:LENR, PVC:LNR and PVC:LENRA) were mixed based on ratio of 70:30. Electrospinning method was used to prepare the fiber. The results show that the spinnable concentration of PVC/ natural rubber/THF solution is 16 wt%. The morphology, diameter, structure and degradation temperature of electrospun fibers were investigated by scanning electron microscopy (SEM) and thermogravimetric analysis (TGA). SEM photos showed that the morphologymore » and diameter of the fibers were mainly affected by the addition of natural rubber. TGA results suggested that PVC electrospun fiber has higher degradation temperature than those electrospun fibers that contain natural rubber.« less
Effect of tubing on loss of clonazepam administered by continuous subcutaneous infusion.
Schneider, Jennifer J; Good, Phillip; Ravenscroft, Peter J
2006-06-01
Previous studies have reported loss of clonazepam from solutions administered intravenously from plastic infusion bags and administration sets. In palliative care, clonazepam is sometimes administered through syringe drivers using polyvinyl chloride (PVC) infusion tubing. No data currently exist to show whether use of PVC tubing affects the amount of clonazepam actually received by the patient. This study compared the use of two different types of PVC tubing with a non-PVC tubing. Solutions containing clonazepam or clonazepam and morphine were prepared with either normal saline or water for injection as diluent. Concentrations of morphine and clonazepam were determined using high-performance liquid chromatography. Significant loss of clonazepam (up to 50%) was observed in all solutions infused through PVC tubing. Solutions infused through non-PVC tubing retained greater than 90% of the initial concentration of clonazepam. It is recommended that when administering clonazepam using a syringe driver, non-PVC tubing be used.
Ashagre, Mekonnen Abiyot; Masadome, Takashi
2018-01-01
A new microfluidic polymer chip with an embedded cationic surfactant (CS) ion-selective optode (CS-optode) as a detector of flow-injection analysis (FIA) for the determination of CSs was developed. The optode sensing membrane is based on a poly(vinyl chloride) membrane plasticized with 2-nitrophenyl octyl ether containing tetrabromophenolphthalein ethyl ester. Under the optimal flow conditions of the FIA system, the CS-optode showed a good linear relationship between the peak heights in the absorbance, and the concentrations of CS in a concentration range from 50 to 400 μmol dm -3 . The sample throughput of the present system for the determination of a CS ion (300 μmol dm -3 zephiramine) was ca. 11 samples h -1 . The proposed FIA system was applied to determine the level of CS in dental rinses.
Rosas-Luis, Rigoberto
2016-12-15
Squids are active and opportunistic predators that feed on a wide range of prey. Their active movements in the water column and their voracity promote a high consumption of food. In the pelagic environment off Ecuador, marine pollution is characterized by plastic debris with a mainland origin, including plastics trash of fishing gears. The objective of this work was to describe the presence of plastic remains in the stomach contents of Dosidicus gigas caught off the coast of Ecuador. Results demonstrated that 12% of the stomachs contained plastic remains. These plastics were identified as multifilament of polyethylene lines and polyvinyl chloride remains. Findings of this work could be related to an increase in the discharge of solid materials in the water column, increasing the probability to be ingested by the jumbo squid. Copyright © 2016 Elsevier Ltd. All rights reserved.
Pilot study on novel blood containers with alternative plasticizers for red cell concentrate storage
Fukui, Chie; Kawakami, Tsuyoshi; Ikeda, Toshiyuki; Mukai, Tomokazu; Yuba, Toshiyasu; Inamura, Ken-ichi; Yamaoka, Hisatoki; Miyazaki, Ken-ichi; Okazaki, Hitoshi
2017-01-01
Di (2-ethylhexyl) phthalate (DEHP), a typical plasticizer used for polyvinyl chloride (PVC) blood containers, is eluted from the blood containers and exerts protective effects on red blood cells. However, a concern for detrimental effects of DEHP on human health has led to the development of potential DEHP substitutes. Here, we compared the red blood cell preservation ability of two types of non-DEHP blood containers with safe alternative plasticizers to that of DEHP blood containers. Red cell concentrates in mannitol-adenine-phosphate solution (MAP/RCC) were stored for 6 weeks in PVC blood bags containing DEHP, di-isononyl-cyclohexane-1,2-dicarboxylate (DINCH) and di (2-ethylhexyl) 4-cyclohexene-1,2-dicarboxylate (DOTH), or 4-cyclohexene-1,2-dicarboxylic acid dinonyl ester (DL9TH) and DOTH. There was no significant difference in the total amount of plasticizer eluted into MAP/RCC (till 3 weeks from the beginning of the experiment), hemolysis of MAP/RCC, and osmotic fragility of MAP/RCC between the non-DEHP blood containers and DEHP blood containers. Hematological and blood chemical indices of MAP/RCC in all containers were nearly the same. Thus, DOTH/DINCH and DOTH/DL9TH blood containers demonstrate the same quality of MAP/RCC storing as the DEHP blood containers. Since DOTH, DINCH, and DL9TH were reported to be safe, DOTH/DINCH and DOTH/DL9TH blood containers are promising candidate substitutes for DEHP blood containers. PMID:28957448
Morishita, Yuki; Nomura, Yusuke; Fukui, Chie; Kawakami, Tsuyoshi; Ikeda, Toshiyuki; Mukai, Tomokazu; Yuba, Toshiyasu; Inamura, Ken-Ichi; Yamaoka, Hisatoki; Miyazaki, Ken-Ichi; Okazaki, Hitoshi; Haishima, Yuji
2017-01-01
Di (2-ethylhexyl) phthalate (DEHP), a typical plasticizer used for polyvinyl chloride (PVC) blood containers, is eluted from the blood containers and exerts protective effects on red blood cells. However, a concern for detrimental effects of DEHP on human health has led to the development of potential DEHP substitutes. Here, we compared the red blood cell preservation ability of two types of non-DEHP blood containers with safe alternative plasticizers to that of DEHP blood containers. Red cell concentrates in mannitol-adenine-phosphate solution (MAP/RCC) were stored for 6 weeks in PVC blood bags containing DEHP, di-isononyl-cyclohexane-1,2-dicarboxylate (DINCH) and di (2-ethylhexyl) 4-cyclohexene-1,2-dicarboxylate (DOTH), or 4-cyclohexene-1,2-dicarboxylic acid dinonyl ester (DL9TH) and DOTH. There was no significant difference in the total amount of plasticizer eluted into MAP/RCC (till 3 weeks from the beginning of the experiment), hemolysis of MAP/RCC, and osmotic fragility of MAP/RCC between the non-DEHP blood containers and DEHP blood containers. Hematological and blood chemical indices of MAP/RCC in all containers were nearly the same. Thus, DOTH/DINCH and DOTH/DL9TH blood containers demonstrate the same quality of MAP/RCC storing as the DEHP blood containers. Since DOTH, DINCH, and DL9TH were reported to be safe, DOTH/DINCH and DOTH/DL9TH blood containers are promising candidate substitutes for DEHP blood containers.
ERIC Educational Resources Information Center
Stringer, Ruth; Labounskaia, Irina; Santillo, David; Johnston, Paul; Siddorn, John; Stephenson, Angela
Polyvinyl chloride (vinyl or PVC) is widely used in toys and other children's products. This study, conducted by Greenpeace, examined the composition and quantity of phthalate ester additives in children's PVC toys, used to give the toys added flexibility. Drawn from 17 countries, a total of 71 toys designed to be chewed by babies and young…
2005-04-01
Bray-Curtis distance measure with an Unweighted Pair Group Method with Arithmetic Averages ( UPGMA ) linkage method to perform a cluster analysis of the...59 35 Comparison of reef condition indicators clustering by UPGMA analysis...Polyvinyl Chloride RBD Red-band Disease SACEX Supporting Arms Coordination Exercise SAV Submerged Aquatic Vegetation SD Standard Deviation UPGMA
Bags of toys: the demise of PVC.
Williams, D
1999-01-01
Poly(vinyl chloride) (PVC) is a widely used commodity plastic that has many applications in medical devices. Recent concerns over the oestrogenic activity of some of the phthalate plasticizers used in PVC, and the hazards associated with dioxin that may be produced during the incineration of PVC waste have initiated an assessment of the future role of this material. This article addresses some of the underlying toxicological and risk assessment issues.
David G. Grimble
1988-01-01
Four types of spruce budworm pheromone lures were field-tested in sparse spruce budworm populations in Maine. BioLures® with constant pheromone emission rates less than 1.0, ca. 1.0-1.5, and ca. 15.0 micrograms of pheromone per day were compared to polyvinyl chloride (PVC) lures with rapidly decreasing pheromone emission rates. Mean trap catch was roughly proportional...
PVC: health implications and production trends.
Karstadt, M
1976-01-01
Poly(vinyl chloride) (PVC) is a complex plastic system. Individual components of the PVC system, including residual vinyl chloride monomer (RVCM) and certain additives, may pose risks of harm to human health. There have been significant reductions in the RVCM content of PVC resin since 1974, reducing the cancer risk of workers in PVC fabrication plants and consumers of PVC products. A "no-effect" level for vinyl chloride monomer (VCM)-induced carcinogenesis has not been found to date; therefore, the significance of human exposure to low levels of RVCM remains to be determined. Exposure to PVC dust may cause pulmonary dysfunctions. Pulmonary and other possible health effects of PVC dust require further study. The PVC plastics system should be characterized as to interactions among its various components and as to interactions of the components and the PVC system as a whole with biological systems. Images FIGURE 1. FIGURE 2. PMID:799961
NASA Astrophysics Data System (ADS)
Chuaponpat, N.; Areerat, S.
2017-11-01
This research studies the effects of foaming conditions by using liquid carbon dioxide (CO2) as a physical blowing agent on plasticized polyvinyl chloride (PVC) foam morphology. Foaming conditions were soaking time of 6, 10, and 12 h, foaming temperature of 70, 80, 90 °C for 5 s, at constant soaking temperature of -20 °C and pressure of 50 bar. Instantaneously increasing temperature was employed in this process for making foam structure. PVC foam samples were calculated percentage of shrinkage (Sh) by using density at before and after aging process at 30 °C for 12 h. When PVC samples were activated to form foam by using liquid CO2 as a physical blowing agent, it reveal bimodal foam structure with a thick bubble wall (10-20 μm). Bubble diameter of PVC foam at longer soaking time is in the range of 40-60 μm and its at shorter soaking time reveal a large bubble that is in the range of 80-120 μm. Foaming condition slightly affected to bubble density that was in the narrow range of 106-108 bubbles/cm3. PVC foam reveal reduction of density up to 65% when compare with PVC and Sh is less than 10%.
Kirbas, Ahmet; Celik, Sezai; Gurer, Onur; Yildiz, Yahya; Isik, Omer
2011-01-01
Osteoporosis, a major risk factor for sternum-related morbidity after median sternotomy, is quite prevalent among the elderly. In this prospective study, we investigated the potential of sternal protection by use of the "sternal wrapping method" in elderly osteoporotic patients who were undergoing median sternotomy.For this study, we chose 100 elderly osteoporotic patients who were scheduled to undergo median sternotomy. During surgery, we wrapped the sternal edges with polyvinyl chloride tubing in 50 patients (group 1) and omitted the sternal wrapping in the remaining 50 patients (group 2). We then compared the groups with regard to postoperative pain, bleeding, early and late sternum-related morbidity, sternal fractures, and duration of hospitalization.Sternal wrapping was associated with fewer sternal fractures, less chest pain, and shorter hospital stays. Overall sternal morbidity was significantly less common among patients with sternal wrapping (4% vs. 20%, P = 0.03); however, the difference in individual rates for early and late dehiscence or deep sternal infection did not reach statistical significance.Sternal wrapping using polyvinyl chloride tubes provides mechanical protection and, apparently, less postoperative chest pain and shorter hospitalizations. Probably, it reduces sternum-related complications, particularly in high-risk patients. Its benefits, however, should be confirmed in larger studies.
Kirbas, Ahmet; Celik, Sezai; Gurer, Onur; Yildiz, Yahya; Isik, Omer
2011-01-01
Osteoporosis, a major risk factor for sternum-related morbidity after median sternotomy, is quite prevalent among the elderly. In this prospective study, we investigated the potential of sternal protection by use of the “sternal wrapping method” in elderly osteoporotic patients who were undergoing median sternotomy. For this study, we chose 100 elderly osteoporotic patients who were scheduled to undergo median sternotomy. During surgery, we wrapped the sternal edges with polyvinyl chloride tubing in 50 patients (group 1) and omitted the sternal wrapping in the remaining 50 patients (group 2). We then compared the groups with regard to postoperative pain, bleeding, early and late sternum-related morbidity, sternal fractures, and duration of hospitalization. Sternal wrapping was associated with fewer sternal fractures, less chest pain, and shorter hospital stays. Overall sternal morbidity was significantly less common among patients with sternal wrapping (4% vs 20%, P = 0.03); however, the difference in individual rates for early and late dehiscence or deep sternal infection did not reach statistical significance. Sternal wrapping using polyvinyl chloride tubes provides mechanical protection and, apparently, less postoperative chest pain and shorter hospitalizations. Probably, it reduces sternum-related complications, particularly in high-risk patients. Its benefits, however, should be confirmed in larger studies. PMID:21494519
In-Line Ultrasonic Monitoring for Sediments Stuck on Inner Wall of a Polyvinyl Chloride Pipe
2014-01-01
This research verified the applicability and effectiveness of the ultrasonic monitoring of sediments stuck on the inner wall of polyvinyl chloride (PVC) pipes. For identifying the transmittance of acoustic energy and the speed of sound in the PVC material, the pulse-echo ultrasonic testing was conducted for PVC sheets of different thicknesses. To simulate the solidified sediment, the hot melt adhesive (HMA) was covered on the inner wall of the PVC pipe in different heights. From the experiment, the speeds of sound in the PVC and the HMA materials were obtained as about 2258 and 2000 m/s, respectively. The thickness of the materials was calculated through the signal processing such as taking the absolute value and low pass filtering, the echo detection, and the measurement of the time of flight. The errors between actual and measured thicknesses of PVC sheets were below 5%. In the case of the substance stuck on the inner wall, the errors were below 2.5%. Since the pulse-echo ultrasonic inspection is available on the outer surface and its measurement accuracy was over 95%, it can be an efficient and effective in-service structural health monitoring for the sediment on the wall of PVC pipes. PMID:25243223
Zhang, Yanhao; Zhong, Fohua; Xia, Siqing; Wang, Xuejiang; Li, Jixiang
2009-10-15
A hollow fiber membrane biofilm reactor (MBfR) using polyvinyl chloride (PVC) hollow fiber was evaluated in removing nitrate form contaminated drinking water. During a 279-day operation period, the denitrification rate increased gradually with the increase of influent nitrate loading. The denitrification rate reached a maximum value of 414.72 g N/m(3)d (1.50 g N/m(2)d) at an influent NO(3)(-)-N concentration of 10mg/L and a hydraulic residence time of 37.5 min, and the influent nitrate was completely reduced. At the same time, the effluent quality analysis showed the headspace hydrogen content (3.0%) was lower enough to preclude having an explosive air. Under the condition of the influent nitrate surface loading of 1.04 g N/m(2)d, over 90% removal efficiencies of the total nitrogen and nitrate were achieved at the hydrogen pressure above 0.04 MPa. The results of denaturing gel gradient electrophoresis (DGGE), 16S rDNA gene sequence analysis, and hierarchical cluster analysis showed that the microbial community structures in MBfR were of low diversity, simple and stable at mature stages; and the beta-Proteobacteria, including Rhodocyclus, Hydrogenophaga, and beta-Proteobacteria HTCC379, probably play an important role in autohydrogenotrophic denitrification.
Reported vague symptoms and at-risk status: the case of polyvinyl chloride workers in Louisville.
Sands, R G; Greenberg, R A
1987-01-01
This study concerns the frequency of visits to the dispensary by workers with vague symptoms of physical illness at a polyvinyl chloride plant in Louisville, KY, where an outbreak of hepatic angiosarcoma occurred. The illness behavior of three cohorts of workers at three levels of risk--workers removed from the chemical plant to a pallet plant (PP) because their screening results indicated liver abnormalities; workers who had some positive test results (TP); and workers whose test results were negative (TN)--was studied before (time 1) and after (time 2) the angiosarcoma crisis. It was predicted that, during time 2, the groups' visits to the dispensary would increase in relation to their levels of risk (PP greater than TP greater than TN). Although there was an overall increase in the percentage of visits because of vague symptoms during time 2, the only cohort with different behavior was the group of TP workers: they reduced their use of the dispensary. These results are similar to those in a previous study in which all symptoms of illness were included. It is speculated that social and individual factors, as well as the labeling phenomenon, explain the results. Health care providers are encouraged to follow up with workers at risk who seem to avoid monitoring their health. PMID:3112857
Wang, Chongqing; Wang, Hui; Fu, Jiangang; Zhang, Lingling; Luo, Chengcheng; Liu, Younian
2015-11-01
Surface modification with potassium permanganate (KMnO4) solution was developed for separation of polyvinyl chloride (PVC) and polyethylene terephthalate (PET) waste plastics. The floatability of PVC decreases with increasing of KMnO4 concentration, treatment time, temperature and stirring rate, while that of PET is unaffected. Fourier transform infrared (FT-IR) analysis confirms that mechanism of surface modification may be due to oxidization reactions occurred on PVC surface. The optimum conditions are KMnO4 concentration 1.25 mM/L, treatment time 50 min, temperature 60°C, stirring rate 300 r/min, frother concentration 17.5 g/L and flotation time 1 min. PVC and PET with different particle sizes were separated efficiently through two-stage flotation. Additionally, after ultrasonic assisted surface modification, separation of PVC and PET with different mass ratios was obtained efficiently through one-stage flotation. The purity and the recovery of the obtained products after flotation separation are up to 99.30% and 99.73%, respectively. A flotation process was designed for flotation separation of PVC and PET plastics combined with surface modification. This study provides technical insights into physical separation of plastic wastes for recycling industry. Copyright © 2015 Elsevier Ltd. All rights reserved.
Characterisation of historic plastics using terahertz time-domain spectroscopy and pulsed imaging.
Pastorelli, Gianluca; Trafela, Tanja; Taday, Phillip F; Portieri, Alessia; Lowe, David; Fukunaga, Kaori; Strlič, Matija
2012-05-01
Terahertz (THz) time-domain spectroscopy and 3D THz pulsed imaging have been explored with regard to polymer materials, both commodity and historic polymers. A systematic spectroscopic study of a wide range of different polymer materials showed significant differences in their spectra. Polyolefins and polystyrenes generally exhibit lower absorption than other examined polymers, various cellulose derivates, poly(vinyl chloride), poly(methyl methacrylate), polyamide, hard rubber and phenol formaldehyde resin, the last of these exhibiting the most intense absorption over the entire range, 0.15-4.2 THz. It was also examined how the presence of plasticisers in poly(vinyl chloride), the presence of fillers in polypropylene, and the degree of branching in polyethylene and polystyrene affect the spectra; inorganic fillers in polypropylene affected the absorption most. With 3D THz pulsed imaging, features in polymer objects were explored, appearing either as integral parts of the material (coatings and pores in foams) or as a consequence of physical deterioration (cracks, delamination). All of these features of various complexities can be successfully imaged in 3D. Terahertz technology is thus shown to have significant potential for both chemical and structural characterisation of polymers, which will be of interest to heritage science, but also to the polymer industry and development of analytical technologies in general.
Romano, Nicholas; Ashikin, Munirah; Teh, Jun Chin; Syukri, Fadhil; Karami, Ali
2018-06-01
Silver barb Barbodes gonionotus fry were exposed to polyvinyl chloride (PVC) fragments at increasing concentrations of 0.2, 0.5 and 1.0 mg/L for 96 h, following which whole body histological evaluation and analysis of the digestive enzymes trypsin and chymotrypsin were performed. Whole body trypsin and chymotrypsin activities increased significantly in fish exposed to 0.5 and 1.0 mg/L PVC as compared those exposed to zero or 0.2 mg/L PVC. In fish exposed to all tested concentrations, PVCs were observed in both the proximal and distal intestine, and fish exposed to 0.5-1.0 and 1.0 mg/L PVC, respectively, and these particles were associated with localized thickening of the mucosal epithelium. No tissue damage was evident in any other internal organs or gills. This lack of damage may be attributed to the absence of contaminants associated with the PVC fragments and their relatively smooth surface. The increased whole body trypsin and chymotrypsin activities may indicate an attempt to enhance digestion to compensate for epithelial thickening of the intestine and/or to digest the plastics. Copyright © 2017 Elsevier Ltd. All rights reserved.
Greenway, Joseph A; Gerstenberger, Shawn
2010-10-01
Childhood exposure to environmental lead continues to be a major health concern. This study examined lead content within the plastic of children's toys collected from licensed day care centers in the Las Vegas valley, Nevada. It was hypothesized that the use of lead as a plastics stabilizer would result in elevated lead (≥600 ppm) in polyvinyl chloride plastics (PVC) compared to non-PVC plastics. It was also hypothesized that, due to the use of lead chromate as a coloring agent, yellow toys would contain higher concentrations of lead (≥600 ppm) than toys of other colors. Toy samples were limited to those found in day care centers in Las Vegas, Nevada. 10 day care centers were visited and approximately 50 toy samples were taken from each center. Of the 535 toys tested, 29 contained lead in excess of 600 parts per million (ppm). Of those 29 toys, 20 were PVC and 17 were yellow. Both of the two hypotheses were strongly supported by the data.
NASA Astrophysics Data System (ADS)
Yanqoritha, Nyimas; Turmuzi, Muhammad; Derlini
2017-05-01
The appropriate process to resolve sewage contamination which have a high organic using anaerobic technology. Hybrid Upflow Anaerobic Sludge Blanket reactor is one of the anaerobic process which consists of a suspended growth media and attached growth media. The reactor has the ability to work at high load rate, sludge produced easily settles, high biomass and the separation of gas, solid and liquid excelent. The purpose of research is to study the acclimatization process in the reactor of Hybrid Upflow Anaerobic Sludge Blanket using a polyvinl chloride ring as the attached growth medium. Reactor of Hybrid Upflow Anaerobic Sludge Blanket use a working volume of 8.6 L. The operation consisting of 3 L suspended reactor and 5.6 L attached reactor. Acclimatization is conducted by providing the substrate from the smallest concentration of COD up to a concentration that will be processed. During the 50th day, acclimatization process assumed the bacteria begin to work, indicated by the dissolved COD and VSS decrease and biogas production. Due to the wastewater containing the high of protein in consequence operational parameters should be controlled and some precautions should be taken to prevent process partially or totally inhibited.
Clark, Dennis A.; Izbicki, John A.; Metzger, Loren F.; Everett, Rhett; Smith, Gregory A.; O'Leary, David R.; Teague, Nicholas F.; Burgess, Matthew K.
2012-01-01
Data were collected by the U.S. Geological Survey from 2003 through 2008 in the Eastern San Joaquin Groundwater Subbasin, 80 miles east of San Francisco, California, as part of a study of the increasing chloride concentrations in groundwater processes. Data collected include geologic, geophysical, chemical, and hydrologic data collected during and after the installation of five multiple-well monitoring sites, from three existing multiple-well sites, and from 79 selected public-supply, irrigation, and domestic wells. Each multiple-well monitoring site installed as part of this study contained three to five 2-inch diameter polyvinyl chloride (PVC)-cased wells ranging in depth from 68 to 880 feet below land surface. Continuous water-level data were collected from the 19 wells installed at these 5 sites and from 10 existing monitoring wells at 3 additional multiple-well sites in the study area. Thirty-one electromagnetic logs were collected seasonally from the deepest PVC-cased monitoring well at seven multiple-well sites. About 200 water samples were collected from 79 wells in the study area. Coupled well-bore flow data and depth-dependent water-quality data were collected from 12 production wells under pumped conditions, and well-bore flow data were collected from 10 additional wells under unpumped conditions.
Ferguson, Stephen A; Meyerhoff, Mark E
2017-10-27
The detection of four different polyquaterniums (PQs) using a fully reversible potentiometric polyion sensor in three different detection modes is described. The polyion sensing "pulstrodes" serve as the detector for direct dose-response experiments, beaker titrations, and in a flow-injection analysis (FIA) system. Direct polycation response toward PQ-2, PQ-6, PQ-10, and poly(2-methacryloxyethyltrimethylammonium) chloride (PMETAC) yields characteristic information about each PQ species (e.g., relative charge densities, etc.) via syringe pump addition of each PQ species to a background electrolyte solution. Quantitative titrations are performed using a syringe pump to deliver heparin as the polyanion titrant to quantify all four PQs at μg/mL levels. Both the direct and indirect methods incorporate the use of a three-electrode system including counter, double junction reference, and working electrodes. The working electrode possesses a plasticized poly(vinyl chloride) (PVC) membrane containing the neutral lipophilic salt of dinonylnaphthalenesulfonate (DNNS - ) tridodecylmethylammonium (TDMA + ). Further, the titration method is shown to be useful to quantify PQ-6 levels in recreational swimming pool water collected in Ann Arbor, MI. Finally, a FIA system equipped with a pulstrode detector is used to demonstrate the ability to potentially quantify PQ levels via a more streamlined and semiautomated testing platform.
NASA Astrophysics Data System (ADS)
Nishio, Takashi; Naka, Kensuke
2015-04-01
Photoinduced crystallization of calcium carbonate (CaCO3) was demonstrated by the photodecarboxylation of ketoprofen (KP, 2-(3-benzoylphenyl)propionic acid) under alkaline conditions (pH 10). In this method, a homogeneous solution comprising KP, calcium chloride, ammonia, and partially hydrolyzed poly(vinyl alcohol) (PVAPS, degree of saponification: 86.5-89.0 mol %) was used as the precursor solution and was exposed to ultraviolet (UV) irradiation for different time periods. Thermogravimetric analysis of the obtained xerogels showed that increasing the UV irradiation time increased the amount of CaCO3 formed and the complete conversion of calcium ions to calcite was achieved after 50 min of UV irradiation. Furthermore, solid phase analyses suggested that nanometer-to-micron-sized calcite crystals were formed and dispersed in the obtained PVAPS matrix.
Novel Elastomeric Closed Cell Foam - Nonwoven Fabric Composite Material (Phase III)
2008-10-01
increasing the polymer content of the foam. From laboratory studies, processing was found to improve by using different types of NBR rubber . The AF07 B...Foam Optimization (Task 1) Prior development of fire retarded closed cell foam yielded attractive candidates for scale-up. Nitrile-butadiene rubber ... NBR ) and polyvinyl chloride (PVC) blends provided the most cost effective solutions. Two types of formulas were chosen for optimization. The first
Work Plan and Field Sampling Plan Site Investigations Fort Devens, Massachusetts
1992-02-01
Plan PPE Personal Protective Equipment PPM Parts Per Million PRI Potomac Research , Inc. PSI Pounds Per Square Inch PVC Polyvinyl Chloride QAPjP Quality...Aquifers with Completely or Partially Penetrating Wells, Water Resources Research , 12: 423-428. Brackley, Richard A. and B. P. Hansen, 1977, Water...of a Finite Diameter Well to an Instantaneous Charge of Water, Water Resources Research , 3: 263-269. Directorate of Engineering and Housing (DEH
1979-05-01
polyethylene (PE), polyvinyl chloride (PVC), butyl rubber , Hyalon (a registered trademark of Dupont), ethylene propylene diene monomer ( EPDM ), chlorinated...studies are explained in part by the following factors: age of the landfill and corresponding state of stabilization; composition of the solid waste, the...an active anaerobic population of methane formers. The removal of organics resulted in a more rapid stabilization or " aging " of the experimental
Design and Prototyping of a Satellite Antenna Slew Testbed
2013-12-01
polycarbonate plastic PC personal computer PD proportional derivative PDO process data objects PVC polyvinyl chloride PVT position...part. The CAD model of the current design iteration can be exported to 3D printer to produce a plastic prototype of the testbed assembly. The 3D... extruded shaft) and connected by set screws as shown in Figure 8. The set screws translate the force from motor to gears to shaft, thus creating an
2016-12-30
Operational Variable LeakFinderRT Equipment Logistics Portable Case Pipe Material Pit Cast Iron, Spun Cast Iron, Steel , Ductile Iron, Asbestos Cement ...AND ACRONYMS AC asbestos cement AMI advanced metering infrastructure AWWA American Water Works Association CI cast iron DI ductile iron DoD...assessing their ability to detect and accurately locate leaks in challenging pipe types such as polyvinyl chloride (PVC), asbestos cement (AC), and
1995-03-15
billion volume ppm parts per million PT pole-mounted PTFE polytetrafluoro-ethylene PUF polyurethane foam PVC polyvinyl chloride QA quality assurance...and Illinois Environmental Protection Agency (IEPA) quality assurance (QA) objectives. The format of the OQAPP is based on "Interim Guidelines and...County. The till material deposited in the Fort Sheridan region has been classified as the Wadsworth Till Member of the Wedron Formation . This till
The Mediterranean Plastic Soup: synthetic polymers in Mediterranean surface waters.
Suaria, Giuseppe; Avio, Carlo G; Mineo, Annabella; Lattin, Gwendolyn L; Magaldi, Marcello G; Belmonte, Genuario; Moore, Charles J; Regoli, Francesco; Aliani, Stefano
2016-11-23
The Mediterranean Sea has been recently proposed as one of the most impacted regions of the world with regards to microplastics, however the polymeric composition of these floating particles is still largely unknown. Here we present the results of a large-scale survey of neustonic micro- and meso-plastics floating in Mediterranean waters, providing the first extensive characterization of their chemical identity as well as detailed information on their abundance and geographical distribution. All particles >700 μm collected in our samples were identified through FT-IR analysis (n = 4050 particles), shedding for the first time light on the polymeric diversity of this emerging pollutant. Sixteen different classes of synthetic materials were identified. Low-density polymers such as polyethylene and polypropylene were the most abundant compounds, followed by polyamides, plastic-based paints, polyvinyl chloride, polystyrene and polyvinyl alcohol. Less frequent polymers included polyethylene terephthalate, polyisoprene, poly(vinyl stearate), ethylene-vinyl acetate, polyepoxide, paraffin wax and polycaprolactone, a biodegradable polyester reported for the first time floating in off-shore waters. Geographical differences in sample composition were also observed, demonstrating sub-basin scale heterogeneity in plastics distribution and likely reflecting a complex interplay between pollution sources, sinks and residence times of different polymers at sea.
The Mediterranean Plastic Soup: synthetic polymers in Mediterranean surface waters
NASA Astrophysics Data System (ADS)
Suaria, Giuseppe; Avio, Carlo G.; Mineo, Annabella; Lattin, Gwendolyn L.; Magaldi, Marcello G.; Belmonte, Genuario; Moore, Charles J.; Regoli, Francesco; Aliani, Stefano
2016-11-01
The Mediterranean Sea has been recently proposed as one of the most impacted regions of the world with regards to microplastics, however the polymeric composition of these floating particles is still largely unknown. Here we present the results of a large-scale survey of neustonic micro- and meso-plastics floating in Mediterranean waters, providing the first extensive characterization of their chemical identity as well as detailed information on their abundance and geographical distribution. All particles >700 μm collected in our samples were identified through FT-IR analysis (n = 4050 particles), shedding for the first time light on the polymeric diversity of this emerging pollutant. Sixteen different classes of synthetic materials were identified. Low-density polymers such as polyethylene and polypropylene were the most abundant compounds, followed by polyamides, plastic-based paints, polyvinyl chloride, polystyrene and polyvinyl alcohol. Less frequent polymers included polyethylene terephthalate, polyisoprene, poly(vinyl stearate), ethylene-vinyl acetate, polyepoxide, paraffin wax and polycaprolactone, a biodegradable polyester reported for the first time floating in off-shore waters. Geographical differences in sample composition were also observed, demonstrating sub-basin scale heterogeneity in plastics distribution and likely reflecting a complex interplay between pollution sources, sinks and residence times of different polymers at sea.
Transformation of methyltin chlorides and stannic chloride under simulated landfill conditions.
Björn, Annika; Hörsing, Maritha; Ejlertsson, Jörgen; Svensson, Bo H
2011-12-01
There is increasing concern regarding the fate of methyltins in the environment, particularly since large amounts of polyvinyl chloride (PVC) plastics are deposited in landfills. The potential transformation of methyltin chlorides and stannic chloride in landfills was investigated, by incubating the target substances at concentrations relevant to landfill conditions (100 and 500 µg Sn L(-1)). The amounts of methane formed in all treatment bottles, and controls, were measured to evaluate the general microbial activity of the inocula and possible effects of methyltins on the degradation of organic matter. The methyltins and stannic chloride were found to have no significant inhibitory effects on the activity of landfill micro-organisms, and the methanol used to disperse the tin compounds was completely degraded. In some experimental bottles, the methanol degradation gave rise to larger methane yields than expected, which was attributed to enhanced degradation of the waste material. Alkyltin analyses showed that monomethyltin trichloride at an initial concentration of 500 µg Sn L(-1) promoted methylation of inorganic tin present in the inoculum. No methylation activities were detected in the incubations with 100 µg Sn L(-1) methyltin chlorides (mono-, di- or tri-methyltin), but demethylation occurred instead. Levels of soluble inorganic tin increased during the incubation period, due partly to demethylation and partly to a release of tin from the waste inocula.
Suppressing effect of goethite on PCDD/F and HCB emissions from plastic materials incineration.
Jin, Guang-Zhu; Lee, Se-Jin; Kang, Jung-Ho; Chang, Yoon-Seok; Chang, Yoon-Young
2008-02-01
Polyethylene (PE) and polyvinyl chloride (PVC) are the leading plastics in total production in the world. The incineration of plastic-based materials forms many chlorinated compounds, such as polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans (PCDD/Fs). In this study the addition of goethite (alpha-FeOOH) was investigated to determine its suppressing effect on the emission of PCDD/Fs and hexachlorobenzene (HCB) during the combustion of wastes containing PE and PVC. Goethite was being considered since it acts as a dioxin-suppressing catalyst during incineration. Results showed that incorporation of goethite greatly reduced the generation of PCDD/Fs and HCB in the exhaust gas and fly ash. The concentration of PCDD/Fs in flue gas decreased by 45% for lab-scale and 52% for small incinerator combustion experiments, where the goethite ratios in feed samples were 0.54% and 0.34%, respectively. Under the same conditions, the concentration of HCB in flue gas decreased by 88% and 62%, respectively. The present study showed a possible mechanism of the suppressing effect of the goethite for PCDD/F formation. It is likely that iron chlorides react with particulate carbon to form organo-chlorine compounds and promote PCDD/F formation in the gas phase. XRD analysis of combustion ash revealed that the goethite was partially dehydrated and converted to alpha-Fe(2)O(3) and Fe(3)O(4) but no iron chlorides formation. Therefore the goethite impregnated plastics can contribute the reduction of PCDD/Fs and HCB in the exhaust gas during incineration of MSW.
Organogel polymers from 10-undecenoic acid and poly(vinyl acetate)
USDA-ARS?s Scientific Manuscript database
Organogels are used in a variety of high value applications including the removal of toxic solvents from aqueous environments and the time-controlled release of compounds. One of the most promising gelators is a polyvinyl polymer containing medium chain length carboxylic acids. The existing producti...
USDA-ARS?s Scientific Manuscript database
This study aimed to develop and characterize biodegradable films containing mucilage, chitosan and polyvinyl alcohol (PVA) in different concentrations. The films were prepared by casting on glass plates using glycerol as plasticizer. Mechanical properties, water vapor and oxygen barrier, as well as ...
Immobilization of ammonia-oxidizing bacteria by polyvinyl alcohol and sodium alginate.
Dong, Yuwei; Zhang, Yanqiu; Tu, Baojun
Ammonia-oxidizing bacteria were immobilized by polyvinyl alcohol (PVA) and sodium alginate. The immobilization conditions and ammonia oxidation ability of the immobilized bacteria were investigated. The following immobilization conditions were observed to be optimal: PVA, 12%; sodium alginate, 1.1%; calcium chloride, 1.0%; inoculum concentration, 1.3 immobilized balls/mL of immobilized medium; pH, 10; and temperature, 30°C. The immobilized ammonia-oxidizing bacteria exhibited strong ammonia oxidation ability even after being recycled four times. The ammonia nitrogen removal rate of the immobilized ammonia-oxidizing bacteria reached 90.30% under the optimal immobilization conditions. When compared with ammonia-oxidizing bacteria immobilized by sodium alginate alone, the bacteria immobilized by PVA and sodium alginate were superior with respect to pH resistance, the number of reuses, material cost, heat resistance, and ammonia oxidation ability. Copyright © 2017 Sociedade Brasileira de Microbiologia. Published by Elsevier Editora Ltda. All rights reserved.
Assessment of relative flammability and thermochemical properties of some thermoplastic materials
NASA Technical Reports Server (NTRS)
Kourtides, D. A.; Parker, J. A.
1978-01-01
The thermochemical and flammability characteristics of some typical thermoplastic materials currently in use and others being considered for use in aircraft interiors are described. The properties studied included (1) thermal mechanical properties such as glass transition and melt temperature, (2) changes in polymer enthalpy by differential scanning calorimetry, (3) thermogravimetric analysis in an anaerobic and oxidative environment, (4) oxygen index, (5) smoke evolution, (6) relative toxicity of the volatile products of pyrolysis, and (7) selected physical properties. The generic polymers which were evaluated included: acrylonitrile-butadiene-styrene, bisphenol A polycarbonate, bisphenol fluorenone carbonatedimethylsiloxane block polymer, phenolphthalein-bisphenol A polycarbonate, phenolphthalein polycarbonate, polyether sulfone, polyphenylene oxide, polyphenylene sulfide, polyaryl sulfone, chlorinated polyvinyl chloride homopolymer, polyvinyl fluoride, and polyvinylidene fluoride. Processing parameters including molding characteristics of some of the advanced polymers are described. Test results and relative rankings of some of the flammability, smoke and toxicity properties are presented.
Thermoplastic polymers for improved fire safety
NASA Technical Reports Server (NTRS)
Kourtides, D. A.; Parker, J. A.; Hilado, C. J.
1976-01-01
The thermochemical and flammability characteristics of some typical thermoplastic materials currently in use and others being considered for use in aircraft interiors are described. The properties studied included (1) thermomechanical properties such as glass transition and melt temperature, (2) changes in polymer enthalpy by differential scanning calorimetry, (3) thermogravimetric analysis in anaerobic and oxidative environments, (4) oxygen index, (5) smoke evolution, (6) relative toxicity of the volatile products of pyrolysis, and (7) selected physical properties. The generic polymers that were evaluated included: acrylonitrile butadiene styrene, bisphenol A polycarbonate, 9,9 bis (4-hydroxyphenyl) fluorene polycarbonatepoly (dimethyl siloxane) block polymer, phenolphthalein bisphenol A polycarbonate, phenolphthalein polycarbonate, polyether sulfone, polyphenylene oxide, polyphenylene sulfide, polyaryl sulfone, chlorinated polyvinyl chloride homopolymer, polyvinyl fluoride, and polyvinylidene fluoride. Processing parameters, including molding characteristics of some of the advanced polymers, are described. Test results and relative ranking of some of the flammability, smoke, and toxicity properties are presented.
Translations on Near East and North Africa, Number 1662
1977-06-07
Group 5D, 5C, 5K, 15 18. Availability Statement Unlimited Availability Sold by NTIS Springfield, Virginia 22151 19. Security Class (This...branch stations. Ŗ. Nineteen villages have been built in the desert at a cost of 1.25 million dinars. Each includes 820 homes, 19 schools , 19 clinics...will produce 150,000 tons of polyethylene and polyvinyl chloride and 40,000 tons of caustic soda per year. In addition to all these projects which
Dielectric Constant and Loss Data Part 2
1975-12-01
fluoride, single crystal, Melamine - formaldehyde resins , Columbia Univ., P.R.-75 IV-21,22,112; V-8,88 Manganese-magnesium ferrite, Melamine GMG, IV-2i...butylperoxy) Urea - formaldehyde resins , IV-23 hexane, P.R.-197 U.S. Army Engineering Research and War Dept., Picatinny Arsenal, see Dev. Lab., Fort...IV.-36 irradiated, P.R,-161 "Bakelite" polyvinyl chloride- "Amplifilm," IV-14; V-74 acetate, see "Vinylites" Axiiliine- formaldehyde resins , IV-21
New Polymeric Materials Expected to Have Superior Properties for Space-Based Use.
1985-07-01
Polymethacrylic esters Polvacrylic esters GB3 +CH 2-CH1 +CH 2-C4 COOR COOR Pa lyacrylamide Polymethacrylamide +CH -CH+ CH CONH 2 JCH 2-C4 Polyvinyl chloride...fl.. tetracarboxylic acid dianhydride or with pyromellitic dianhydride. These polymers have shown excellent thermal and radiolytic stability...than the crosslinked phthalocyanines. They can be dissolved in sulfuric acid and sublimed into thin films. 2 2 ,2 3 No mechanical properties have been
Ezerskis, Z; Morkūnas, V; Suman, M; Simoneau, C
2007-11-26
Fourteen poly(vinyl chloride) (PVC) gasket seals and 15 samples of pesto, tomatoes sauces, olive oil and olives in oil were analysed for the additives and plasticisers. The systematic screening of the representative samples revealed that epoxidised soybean oil (ESBO) was the principal plasticiser in eight gaskets and the concentrations of the substance ranged from 15% to 42%. Diisodecyl phthalate (DIDP) as main plasticiser was revealed in three samples and the amount ranged from 37 to 41%. Polyadipate was added in four samples at 16-46%. The concentration of ESBO exceeded 60 mg kg(-1) in three food samples with extreme at 281.9 mg kg(-1) and average 61.3 mg kg(-1). Di-(2-ethylhexyl) phthalate (DEHP) was detected in six food samples and it ranged from 2.5 to 8.7 mg kg(-1). The concentration of DEHP exceeded SML (3 mg kg(-1)) in five cases. The concentration of total polyadipate (PA) was 16.3 mg kg(-1) in average. All eight positive food samples for total PA showed the concentrations below SML (30 mg kg(-1)), which are specified for the fraction of polyadipates lower than 1000 Da. The migration rate of polyadipate in the food ranged from 1 to 7%. At such low transfer rate the polyadipates could be promising plasticisers for PVC gasket seals used in food industry.
Fristachi, Anthony; Xu, Ying; Rice, Glenn; Impellitteri, Christopher A; Carlson-Lynch, Heather; Little, John C
2009-11-01
The leaching of organotin (OT) heat stabilizers from polyvinyl chloride (PVC) pipes used in residential drinking water systems may affect the quality of drinking water. These OTs, principally mono- and di-substituted species of butyltins and methyltins, are a potential health concern because they belong to a broad class of compounds that may be immune, nervous, and reproductive system toxicants. In this article, we develop probability distributions of U.S. population exposures to mixtures of OTs encountered in drinking water transported by PVC pipes. We employed a family of mathematical models to estimate OT leaching rates from PVC pipe as a function of both surface area and time. We then integrated the distribution of estimated leaching rates into an exposure model that estimated the probability distribution of OT concentrations in tap waters and the resulting potential human OT exposures via tap water consumption. Our study results suggest that human OT exposures through tap water consumption are likely to be considerably lower than the World Health Organization (WHO) "safe" long-term concentration in drinking water (150 microg/L) for dibutyltin (DBT)--the most toxic of the OT considered in this article. The 90th percentile average daily dose (ADD) estimate of 0.034 +/- 2.92 x 10(-4)microg/kg day is approximately 120 times lower than the WHO-based ADD for DBT (4.2 microg/kg day).
NASA Astrophysics Data System (ADS)
Khoryani, Zahra; Seyfi, Javad; Nekoei, Mehdi
2018-01-01
The main aim of this research is to study the effects of polymer molecular weight as well as non-solvent concentration on the phase separation, surface morphology and wettability of polyvinyl chloride (PVC) films. Gel permeation chromatography (GPC) results showed that the Mn of the used PVC grades is 6 × 104, 8.7 × 104 and 1.26 × 105 g/mol. It was found that a proper combination of polymer molecular weight and non-solvent content could result in superhydrophobic and self-cleaning behaviors. Scanning electron microscopy (SEM) results demonstrated that addition of ethanol causes the polymer chains to be severely aggregated at the films' surface forming strand-like structures decorated by nano-scale polymer spheres. The polymer molecular weight was found to affect the degree of porosity which is highly influential on the hydrophobicity of the films. The mechanism of phase separation process was also discussed and it was found that the instantaneous demixing is the dominant mechanism once higher contents of non-solvent were used. However, a delayed demixing mechanism was detected when the lower molecular weight PVC has been used which resulted in a pore-less and dense skin layer. Differential scanning calorimetry was also utilized to study the crystallization and glass transition behavior of samples.
Zhan, Faqiang; Zhang, Haijun; Wang, Jing; Xu, Jiazhi; Yuan, Heping; Gao, Yuan; Su, Fan; Chen, Jiping
2017-08-15
Chlorinated paraffin (CP) mixture is a common additive in polyvinyl chloride (PVC) products as a plasticizer and flame retardant. During the PVC plastic life cycle, intentional or incidental thermal processes inevitably cause an abrupt release of short-chain CPs (SCCPs). In this study, the thermal processing of PVC plastics was simulated by heating PVC flooring at 100-200 °C in a chamber. The 1 h thermal treatment caused the release of 1.9-10.7% of the embedded SCCPs. A developed emission model indicated that SCCP release was mainly controlled by material-gas partitioning at 100 °C. However, release control tended to be subjected to material-phase diffusion above 150 °C, especially for SCCP congeners with shorter carbon-chain lengths. A cascade impactor (NanoMoudi) was used to collect particles of different sizes and gas-phase SCCPs. The elevated temperature resulted in a higher partition of SCCPs from the gas-phase to particle-phase. SCCPs were not strongly inclined to form aerosol particles by nucleation, and less present in the Aitken mode particles. Junge-Pankow adsorption model well fitted the partitioning of SCCPs between the gas-phase and accumulation mode particles. Inhalation exposure estimation indicated that PVC processing and recycling workers could face a considerably high risk for exposure to SCCPs.
Booth, Robert K.; Hotchkiss, Sara C.; Wilcox, Douglas A.
2005-01-01
Summary: 1. Discoloration of polyvinyl chloride (PVC) tape has been used in peatland ecological and hydrological studies as an inexpensive way to monitor changes in water-table depth and reducing conditions. 2. We investigated the relationship between depth of PVC tape discoloration and measured water-table depth at monthly time steps during the growing season within nine kettle peatlands of northern Wisconsin. Our specific objectives were to: (1) determine if PVC discoloration is an accurate method of inferring water-table depth in Sphagnum-dominated kettle peatlands of the region; (2) assess seasonal variability in the accuracy of the method; and (3) determine if systematic differences in accuracy occurred among microhabitats, PVC tape colour and peatlands. 3. Our results indicated that PVC tape discoloration can be used to describe gradients of water-table depth in kettle peatlands. However, accuracy differed among the peatlands studied, and was systematically biased in early spring and late summer/autumn. Regardless of the month when the tape was installed, the highest elevations of PVC tape discoloration showed the strongest correlation with midsummer (around July) water-table depth and average water-table depth during the growing season. 4. The PVC tape discoloration method should be used cautiously when precise estimates are needed of seasonal changes in the water-table.
NASA Astrophysics Data System (ADS)
Nugraha, Aditya D.; Wulandari, Ika O.; Hutami Rahayu, L. B.; Riva'i, Imam; Santojo, D. J. Djoko H.; Sabarudin, Akhmad
2018-01-01
Among the various substances developed through nanoparticles, iron oxide (Fe3O4) nanoparticle is one of the substances that have been widely used in various fields such as industry, agriculture, biotechnology and biomedicine. The synthesis of Fe3O4 nanoparticle can be carried out by two methods, consist of chemical and mechanical synthesis methods. Coprecipitation is one of the most commonly used methods for chemical synthesis. Fe3O4 compounds are easily oxidized because they are amphoteric. To avoid the continuous oxidation process, chemical modification process should be carried out with the addition of a solution of polyvinyl alcohol (PVA). In this study, PVA-coated Fe3O4 nanoparticles were synthesized by in-situ coprecipitation and ultrasonication methods through direct mixing (one-pot synthesis) of the iron (II) chloride tetrahydrate (FeCl2.4H2O), iron (III) chloride hexahydrate (FeCl3.6H2O), and PVA under alkaline condition. The effects of addition amount of NH3solution (by adjusting its flow rate using automated syringe pump) and PVA concentration were gently studied. Interaction of PVA with Fe3O4 nanoparticle was identified by infrared spectroscopy whereas lattice parameters and crystallite sizes of the synthesized Fe3O4 nanoparticles and PVA-coated Fe3O4 nanoparticles were assessed by X-ray diffraction (XRD).
Pin, Jean-Mathieu; Behazin, Ehsan; Misra, Manjusri; Mohanty, Amar
2018-05-02
The dynamic thermal history impact of poly(vinyl chloride) (PVC) has been explored for a wide range of pre-cooling rates, from 1 to 30 °C min-1. A first macroscopic insight into the dynamic thermal history influence has been highlighted through a decrease in the apparent activation energy (Eapp) in the first stage of the glass transition. The overall glass transition Eapp surface was successfully modeled in a polynomial fashion regarding the pre-cooling range. Raman scattering was used to associate the Eapp variations along the glass transition conversion with the stereochemistry evolution during the polymeric relaxation. Herein, the selection of atactic PVC as the polymer model permits us to monitor the glassy polymer segment stereodynamics during the heating ramp through the C-Cl stretching. The intermolecular H-Cl dipole interactions, as well as intramolecular conformational reorganizations among syndiotactic, isotactic and heterotactic polymer sequences, have been associated with non-cooperative and cooperative motions, i.e. the β- and α-process, respectively. The fruitful comparison of the two extreme values of the pre-cooling rates permits us to propose a thermokinetic scenario that explains the occurrence, intensity, and inter-dependence of β- and α-processes in the glassy state and during the glass transition. This scenario could potentially be generalized to all the other polymeric glass-formers.
Electromagnetic-induction logging to monitor changing chloride concentrations
Metzger, Loren F.; Izbicki, John A.
2013-01-01
Water from the San Joaquin Delta, having chloride concentrations up to 3590 mg/L, has intruded fresh water aquifers underlying Stockton, California. Changes in chloride concentrations at depth within these aquifers were evaluated using sequential electromagnetic (EM) induction logs collected during 2004 through 2007 at seven multiple-well sites as deep as 268 m. Sequential EM logging is useful for identifying changes in groundwater quality through polyvinyl chloride-cased wells in intervals not screened by wells. These unscreened intervals represent more than 90% of the aquifer at the sites studied. Sequential EM logging suggested degrading groundwater quality in numerous thin intervals, typically between 1 and 7 m in thickness, especially in the northern part of the study area. Some of these intervals were unscreened by wells, and would not have been identified by traditional groundwater sample collection. Sequential logging also identified intervals with improving water quality—possibly due to groundwater management practices that have limited pumping and promoted artificial recharge. EM resistivity was correlated with chloride concentrations in sampled wells and in water from core material. Natural gamma log data were used to account for the effect of aquifer lithology on EM resistivity. Results of this study show that a sequential EM logging is useful for identifying and monitoring the movement of high-chloride water, having lower salinities and chloride concentrations than sea water, in aquifer intervals not screened by wells, and that increases in chloride in water from wells in the area are consistent with high-chloride water originating from the San Joaquin Delta rather than from the underlying saline aquifer.
Polyvinyl alcohol cross-linked with two aldehydes
NASA Technical Reports Server (NTRS)
Sheibley, D. W.; Rieker, L. L.; Hsu, L. C.; Manzo, M. A. (Inventor)
1982-01-01
A film forming polyvinyl alcohol resin is admixed, in aqueous solution, with a dialdehyde crosslinking agent which is capable of crosslinking the polyvinyl alcohol resin and a water soluble acid aldehyde containing a reactive aldehyde group capable of reacting with hydroxyl groups in the polyvinyl alcohol resin and an ionizable acid hydrogen atom. The dialdehyde is present in an amount sufficient to react with from 1 to 20% by weight of the theoretical amount required to react with all of the hydroxyl groups of the polyvinyl alcohol. The amount of acid aldehyde is from 1 to 50% by weight, same basis, and is sufficient to reduce the pH of the aqueous admixture to 5 or less. The admixture is then formed into a desired physical shape, such as by casting a sheet or film, and the shaped material is then heated to simultaneously dry and crosslink the article.
Chen, Fuchao; Fang, Baoxia; Li, Peng; Zhu, Xuesong; Zhou, Benhong
2014-08-01
This study was to investigate the physical and chemical compatibility of butorphanol with tramadol or fentanyl in 0.9% sodium chloride injections for patient controlled analgesia administration. The solutions were prepared in polyvinyl chloride (PVC) infusion bags and stored without protected from light exposure at room temperature (25 degrees C) or refrigerated (4 degrees C). Over a period of 168 hours, stabilities were determined by visual inspection, pH measurement, and high-pressure liquid chromatography (HPLC) assay of drug concentrations. At both temperatures, admixtures of butorphanol-tramadol and butorphanol-fentanyl were clear in appearance, and no color change or precipitation was observed during the study period. The maximum losses obtained were lower than 5% for the three drugs after 168 hours of storage. The results indicate that, at ambient or refrigerated storage conditions, the drug mixtures of butorphanol-tramadol and butorphanol-fentanyl in 0.9% sodium chloride injections were physically and chemically stable for at least 168 hours when stored in PVC syringes.
Factors influencing lead and iron release from some Egyptian drinking water pipes.
Lasheen, M R; Sharaby, C M; El-Kholy, N G; Elsherif, I Y; El-Wakeel, S T
2008-12-30
The major objective of this study is to assess the effect of stagnation time, pipe age, pipes material and water quality parameters such as pH, alkalinity and chloride to sulfate mass ratio on lead and iron release from different types of water pipes used in Egypt namely polyvinyl chloride (PVC), polypropylene (PP) and galvanized iron (GI), by using fill and dump method. Low pH increased lead and iron release from pipes. Lead and iron release decreased as pH and alkalinity increased. Lead and iron release increased with increasing chloride to sulfate mass ratio in all pipes. EDTA was used as an example of natural organic matter which may be influence metals release. It is found that lead and iron release increased then this release decreased with time. In general, GI pipes showed to be the most effected by water quality parameters tested and the highest iron release. PVC pipes are the most lead releasing pipes while PP pipes are the least releasing.
Development of a novel osmotically driven drug delivery system for weakly basic drugs.
Guthmann, C; Lipp, R; Wagner, T; Kranz, H
2008-06-01
The drug substance SAG/ZK has a short biological half-life and because of its weakly basic nature a strong pH-dependent solubility was observed. The aim of this study was to develop a controlled release (cr) multiple unit pellet formulation for SAG/ZK with pH-independent drug release. Pellets with a drug load of 60% were prepared by extrusion/spheronization followed by cr-film coating with an extended release polyvinyl acetate/polyvinyl pyrrolidone dispersion (Kollidon SR 30 D). To overcome the problem of pH-dependent drug release the pellets were then coated with a second layer of an enteric methacrylic acid and ethyl acrylate copolymer (Kollicoat MAE 30 DP). To increase the drug release rates from the double layered cr-pellets different osmotically active ionic (sodium and potassium chloride) and nonionic (sucrose) additives were incorporated into the pellet core. Drug release studies were performed in media of different osmotic pressure to clarify the main release mechanism. Extended release coated pellets of SAG/ZK demonstrated pH-dependent drug release. Applying a second enteric coat on top of the extended release film coat failed in order to achieve pH-independent drug release. Already low enteric polymer levels on top of the extended release coated pellets decreased drug release rates at pH 1 drastically, thus resulting in a reversal of the pH-dependency (faster release at pH 6.8 than in 0.1N HCl). The addition of osmotically active ingredients (sodium and potassium chloride, and sucrose) increased the imbibing of aqueous fluids into the pellet cores thus providing a saturated drug solution inside the beads and increasing drug concentration gradients. In addition, for these pellets increased formation of pores and cracks in the polymer coating was observed. Hence drug release rates from double layered beads increased significantly. Therefore, pH-independent osmotically driven SAG/ZK release was achieved from pellets containing osmotically active ingredients and coated with an extended and enteric polymer. In contrast, with increasing osmotic pressure of the dissolution medium the in vitro drug release rates decreased significantly.
Haned, Zohra; Moulay, Saad; Lacorte, Silvia
2018-04-12
Flexible poly(vinyl chloride) (PVC) is widely used in the pharmaceutical industry for the manufacture of medical devices (tubes, probes, bags, primary packaging, etc.). The objective of the present study was to develop a procedure to evaluate the migration potential of nine plastic additives in aqueous infusion bags (NaCl 0.9% and glucose 5%): five phthalates, one adipate, two alkylphenols, and benzophenone. Two types of materials were analyzed: (i) new and outdated plasticized PVC (containing 40% of diethylhexyl phthalate DEHP); and (ii) tri-laminate polyethylene-polyamide-polypropylene, a multilayer material presumably exempt from DEHP. In addition, we evaluated the migration of plasticizers from PVC raw materials (film and grain) under controlled conditions to compare the migration levels according to Regulation 2011/10. Solid phase extraction and liquid-liquid extraction with gas-chromatography coupled to mass spectrometry were used in all tests. The migration of DEHP in PVC grain exceeded the maximum regulated level of 5000 μg/kg, whereas the levels were much lower in films. In new PVC bags, DEHP was the only compound detected at 4.31 ± 0.5 μg/L in NaCl 0.9% and 4.29 ± 0.25 μg/L in glucose 5% serums, whereas the levels increased 10 times in three-year shelf-life bags. In multilayer bags, DEHP was not found but instead, two plasticizers were detected namely dibuthylphthalate (DBP) and diethylphthalate (DEP) at 0.7 ± 0.1 μg/L and 4.14 ± 0.6 μg/L, respectively. These plasticizers are not mentioned as additives allowed in materials intended for parenteral use (European Pharmacopoeia 8.0, 3.1.5. and 3.1.6.). Caprolactam was tentatively identified and could have stemmed from the polyamide of the multilayer composite. The levels of phthalates remained low but not negligible and might constitute a risk to public health in the case of reiterative infusions. Copyright © 2018. Published by Elsevier B.V.
Task 3 - Pyrolysis of Plastic Waste. Semiannual report, November 1, 1996--March 31, 1997
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ness, Robert O.; Aulich, Ted R.
1997-12-31
Over the last 50 years, the U.S. Department of Energy (DOE) has produced a wide variety of radioactive wastes from activities associated with nuclear defense and nuclear power generation. These wastes include low-level radioactive solid wastes, mixed wastes, and transuranic (TRU) wastes. A portion of these wastes consists of high- organic-content materials, such as resins, plastics, and other polymers; synthetic and natural rubbers; cellulosic-based materials; and oils, organic solvents, and chlorinated organic solvents. Many of these wastes contain hazardous and/or pyrophoric materials in addition to radioactive species. Physical forms of the waste include ion-exchange resins used to remove radioactive elementsmore » from nuclear reactor cooling water, lab equipment and tools (e.g., measurement and containment vessels, hoses, wrappings, equipment coverings and components, and countertops), oil products (e.g., vacuum pump and lubrication oils), bags and other storage containers (for liquids, solids, and gases), solvents, gloves, lab coats and anti-contamination clothing, and other items. Major polymer and chemical groups found in high-organic-content radioactive wastes include polyvinyl chloride (PVC), low-density polyethylene (LDPE), polypropylene (PP), Teflon(TM), polystyrene (PS), nylon, latex, polyethylene terephthalate (PET), vinyl, high-density polyethylene (HDPE), polycarbonate, nitriles, Tygon(R), butyl, and Tyvec(R).« less
NASA Astrophysics Data System (ADS)
Masoomi, Mohsen; Katbab, Ali Asghar; Nazockdast, Hossein
2006-09-01
Attempts have been made for the first time to prepare a friction material with the characteristic of thermal sensitive modulus, by the inclusion of thermoplastic elastomers (TPE) as viscoelastic polymeric materials into the formulation in order to the increase the damping behavior of the cured friction material. Styrene butadiene styrene (SBS), styrene ethylene butylene styrene (SEBS) and nitrile rubber/polyvinyl chloride (NBR/PVC) blend system were used as TPE materials. In order to evaluate the viscoelastic parameters such as loss factor (tan δ) and storage modulus (E‧) for the friction material, dynamic mechanical analyzer (DMA) were used. Natural frequencies and mode shapes of friction material and brake disc were determined by modal analysis. However, NBR/PVC and SEBS were found to be much more effective in damping behavior. The results from this comparative study suggest that the damping characteristics of commercial friction materials can be strongly affected by the TPE ingredients. This investigation also confirmed that the specimens with high TPE content had low noise propensity.
Gao, Jun; Manard, Benjamin Thomas; Castro, Alonso; ...
2017-02-02
Advances in sample nebulization and injection technology have significantly reduced the volume of solution required for trace impurity analysis in plutonium and uranium materials. Correspondingly, we have designed and tested a novel chip-based microfluidic platform, containing a 100-µL or 20-µL solid-phase microextraction column, packed by centrifugation, which supports nuclear material mass and solution volume reductions of 90% or more compared to standard methods. Quantitative recovery of 28 trace elements in uranium was demonstrated using a UTEVA chromatographic resin column, and trace element recovery from thorium (a surrogate for plutonium) was similarly demonstrated using anion exchange resin AG MP-1. Of ninemore » materials tested, compatibility of polyvinyl chloride (PVC), polypropylene (PP), and polytetrafluoroethylene (PTFE) chips with the strong nitric acid media was highest. Finally, the microcolumns can be incorporated into a variety of devices and systems, and can be loaded with other solid-phase resins for trace element assay in high-purity metals.« less
Hazardous metals in vintage plastic toys measured by a handheld X-ray fluorescence spectrometer.
Miller, Gillian Zaharias; Harris, Zoe E
2015-01-01
Over 100 plastic toys from the 1970s and 1980s, both polyvinyl chloride ("vinyl") and nonvinyl, were analyzed in the study described here using a handheld X-ray fluorescence spectrometer to quantify hazardous metal content. A sampling of recent vinyl toys was also tested. The majority of nonvinyl samples were Fisher Price brand toys. The vinyl toys consisted largely of Barbie dolls and other dolls. Overall, lead or cadmium was found in 67% of vintage plastic toys, frequently at concentrations exceeding current U.S. and European limits. Arsenic was detected at levels of concern in 16% of the samples. In the nonvinyl toys, heavy metal content was found to correlate with certain colors of plastic. The likely sources of the detected metals are discussed. None of the contemporary vinyl toys contained detectable cadmium, lead, or arsenic. Given that vintage toys remain in widespread use by children in homes and other locations, the results illuminate a potential source of heavy metal exposure for children.
Jung, Melissa R; Horgen, F David; Orski, Sara V; Rodriguez C, Viviana; Beers, Kathryn L; Balazs, George H; Jones, T Todd; Work, Thierry M; Brignac, Kayla C; Royer, Sarah-Jeanne; Hyrenbach, K David; Jensen, Brenda A; Lynch, Jennifer M
2018-02-01
Polymer identification of plastic marine debris can help identify its sources, degradation, and fate. We optimized and validated a fast, simple, and accessible technique, attenuated total reflectance Fourier transform infrared spectroscopy (ATR FT-IR), to identify polymers contained in plastic ingested by sea turtles. Spectra of consumer good items with known resin identification codes #1-6 and several #7 plastics were compared to standard and raw manufactured polymers. High temperature size exclusion chromatography measurements confirmed ATR FT-IR could differentiate these polymers. High-density (HDPE) and low-density polyethylene (LDPE) discrimination is challenging but a clear step-by-step guide is provided that identified 78% of ingested PE samples. The optimal cleaning methods consisted of wiping ingested pieces with water or cutting. Of 828 ingested plastics pieces from 50 Pacific sea turtles, 96% were identified by ATR FT-IR as HDPE, LDPE, unknown PE, polypropylene (PP), PE and PP mixtures, polystyrene, polyvinyl chloride, and nylon. Published by Elsevier Ltd.
A discrimination model in waste plastics sorting using NIR hyperspectral imaging system.
Zheng, Yan; Bai, Jiarui; Xu, Jingna; Li, Xiayang; Zhang, Yimin
2018-02-01
Classification of plastics is important in the recycling industry. A plastic identification model in the near infrared spectroscopy wavelength range 1000-2500 nm is proposed for the characterization and sorting of waste plastics using acrylonitrile butadiene styrene (ABS), polystyrene (PS), polypropylene (PP), polyethylene (PE), polyethylene terephthalate (PET), and polyvinyl chloride (PVC). The model is built by the feature wavelengths of standard samples applying the principle component analysis (PCA), and the accuracy, property and cross-validation of the model were analyzed. The model just contains a simple equation, center of mass coordinates, and radial distance, with which it is easy to develop classification and sorting software. A hyperspectral imaging system (HIS) with the identification model verified its practical application by using the unknown plastics. Results showed that the identification accuracy of unknown samples is 100%. All results suggested that the discrimination model was potential to an on-line characterization and sorting platform of waste plastics based on HIS. Copyright © 2017 Elsevier Ltd. All rights reserved.
Evaluation of optical excitation conditions for ruthenium complex for biosensor optodes
NASA Astrophysics Data System (ADS)
Pieper, Sean; Zhong, Zhong; Lear, Kevin L.; Reardon, Ken
2007-03-01
Development of a fiber optic biosensor incorporating genetically engineered enzymes which catalyze chlorinated ethenes in an oxygen-consuming reaction for in situ monitoring of groundwater contaminants motivates optimization of optode excitation conditions. These conditions affect the sensitivity, signal-to-noise, and optode service life impacting the quality of the overall biosensor. Optodes are generally comprised of a fluorophore conjugated with a polymer as a substrate cross linked at the distal end of a fiber optic. We investigate the excitation conditions of tris(4,7-diphenyl-1,10-phenanthroline) ruthenium(II) chloride (Ru(dpp)3) conjugated with poly(vinyl alcohol) (PVOH) as an optode. A reported advantage of Ru(dpp)3 is that it has no emission spectral shift occurring under varying chemical and environmental conditions. Photostability degradation due to photobleaching of Ru(dpp)3 with PVOH as a substrate is explored by varying the optical irradiance of the fluorophore containing optode. Other issues relating to practical implementation of Ru(dpp)3 as oxygen sensitive biosensors will be discussed.
THE GENERAL ECOLOGY AND GROWTH OF A SOLITARY ASCIDIAN, CORELLA WILLMERIANA.
Lambert, Gretchen
1968-10-01
1. A one-year field study of the ecology of the solitary ascidian Corella willmeriana Herdman was conducted between April, 1966, and April, 1967, at the Bremerton Yacht Club, Bremerton, Washington, where two polyvinyl chloride frames containing glass plates were examined at monthly intervals. 2. The results indicate that Corella is a primary colonizer, preferring to settle on clean surfaces. Growth is rapid during the summer, when sexual maturity, corresponding to a size of 12 mm., may be attained in three months and life span is approximately five months. Individuals grow at a slower rate and live longer during the winter; the life span then is seven or eight months. 3. Very young specimens of Corella are frequently overgrown during the winter by the colonial ascidian Diplosoma macdonaldi. The causes of death of adult Corella are not completely known, although a small percentage of them are eaten by the polyclad flatworm Eurylepta leoparda. A luxuriant spring growth of filamentous diatoms may cause death of adult Corella by smothering them.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gao, Jun; Manard, Benjamin Thomas; Castro, Alonso
Advances in sample nebulization and injection technology have significantly reduced the volume of solution required for trace impurity analysis in plutonium and uranium materials. Correspondingly, we have designed and tested a novel chip-based microfluidic platform, containing a 100-µL or 20-µL solid-phase microextraction column, packed by centrifugation, which supports nuclear material mass and solution volume reductions of 90% or more compared to standard methods. Quantitative recovery of 28 trace elements in uranium was demonstrated using a UTEVA chromatographic resin column, and trace element recovery from thorium (a surrogate for plutonium) was similarly demonstrated using anion exchange resin AG MP-1. Of ninemore » materials tested, compatibility of polyvinyl chloride (PVC), polypropylene (PP), and polytetrafluoroethylene (PTFE) chips with the strong nitric acid media was highest. Finally, the microcolumns can be incorporated into a variety of devices and systems, and can be loaded with other solid-phase resins for trace element assay in high-purity metals.« less
Separation of packaging plastics by froth flotation in a continuous pilot plant.
Carvalho, Teresa; Durão, Fernando; Ferreira, Célia
2010-11-01
The objective of the research was to apply froth flotation to separate post-consumer PET (Polyethylene Terephthalate) from other packaging plastics with similar density, in a continuously operated pilot plant. A representative sample composed of 85% PET, 2.5% PVC (Polyvinyl Chloride) and 11.9% PS (Polystyrene) was subjected to a combination of alkaline treatment and surfactant adsorption followed by froth flotation. A mineral processing pilot plant, owned by a Portuguese mining company, was adapted for this purpose. The experimentation showed that it is possible to produce an almost pure concentrate of PET, containing 83% of the PET in feed, in a single bank of mechanical flotation cells. The concentrate grade attained was 97.2% PET, 1.1% PVC and 1.1% PS. By simulation it was shown that the Portuguese recycling industry specifications can be attained if one cleaning and one scavenger stages are added to the circuit. Copyright © 2010 Elsevier Ltd. All rights reserved.
Flue Dust Agglomeration in the Secondary Lead Industry
NASA Astrophysics Data System (ADS)
Schwitzgebel, Klaus
1981-01-01
A secondary lead smelter produces several tons of bag-house dust a day. Appropriate handling of this dust is mandatory to meet the proposed OSHA and EPA workroom and ambient standards. Dust agglomeration proved a successful approach. Dusts with a high concentration of PbCl2, or compounds containing PbCl2 can be agglomerated at much lower temperatures than samples with low PbCl2 concentrations. The chlorine sources are polyvinyl chloride (PVC) battery plate separators. Since PVC is used in Europe to a much greater extent than in the U.S., the composition of feedstock must be considered in equipment selection at U.S. secondary smelters. The vapor pressure characteristics of PbCl2 favor its evaporation at blast furnace temperatures. Condensation occurs in the gas cooling system. Recycling of baghouse dust leads to a buildup of PbCl2 in the smelter. Its removal from the system is eventually necessary through leaching, if charges with a high PVC content are processed.
Construction and demolition waste as a source of PVC for recycling.
Prestes, Sabrina Moretto Darbello; Mancini, Sandro Donnini; Rodolfo, Antonio; Keiroglo, Raquel Carramillo
2012-02-01
Construction and demolition waste can contain considerable amounts of polyvinyl chloride (PVC). This paper describes a study of the recycling of PVC pipes collected from such waste materials. In a sorting facility for the specific disposal of construction and demolition waste, PVC was found to represent one-third of the plastics separated by workers. Pipes were sorted carefully to preclude any possible contamination by poly(ethylene terephthalate) (PET) found in the waste. The material was ground into two distinct particle sizes (final mesh of 12.7 and 8 mm), washed, dried and recycled. The average formulation of the pipes was determined based on ash content tests and used in the fabrication of a similar compound made mainly of virgin PVC. Samples of recycled pipes and of compound based on virgin material were subjected to tensile and impact tests and provided very similar results. These results are a good indication of the application potential of the recycled material and of the fact that longer grinding to obtain finer particles is not necessarily beneficial.
Levels of CEA among vinyl chloride and polyvinyl chloride exposed workers
DOE Office of Scientific and Technical Information (OSTI.GOV)
Anderson, H.A.; Snyder, J.; Lewinson, T.
1978-09-01
In 1974, vinyl chloride exposed workers were found to have an increased risk of malignant disease (hemangiosarcoma of the liver). We have examined 1,147 workers exposed to vinyl chloride monomer in three VC/PVC polymerization plants, and 269 workers from a PVC extrusion plant manufacturing PVC textile leather, exposed to much lower concentrations of vinyl chloride. Included among the comprehensive clinical and laboratory studies conducted was the CEA titer. We obtained, respectively, 1,115 and 248 CEA titers. Multiple factors were demonstrated which affected the distribution of CEA titers. Cigarette use had the greatest effect, followed by history of specific past illnessesmore » and alcohol intake history. After removing these possible confounding effects, the distribution of CEA titers among the polymerization workers was significantly different from the extrusion plant group and from an unexposed comparison group. Of the six job categories analyzed, only production and maintenance workers had CEA titer distributions significantly different from the comparison group and the extrusion workers. The investigation demonstrates that occupational exposures in VC/PVC polymerization plants can cause elevations in the CEA titers of otherwise healthy individuals. Prospective follow-up is necessary before conclusions can be drawn concerning the usefulness of the CEA titer as a predictive indicator of possible increased risk.« less
Stability of Fentanyl Citrate in Polyolefin Bags.
Donnelly, Ronald F
2016-01-01
Fentanyl is used to manage pain because it is a potent lipophilic opiate agonist. The stability of fentanyl in polyolefin bags when diluted to either 10 µg/mL or 50 µg/mL with sodium chloride 0.9% has not been studied. The chemical stability of fentanyl 50 µg/mL packaged in polyvinyl chloride bags has been studied, however, the stability in polyolefin bags is lacking. Polyolefin bags were aseptically filled with either 10-µg/mL or 50-µg/mL fentanyl solution. Containers were then stored at either 5°C and protected from light or 22°C and exposed to light for 93 days. Fentanyl peaks were monitored using a stability-indicatin high-performance liquid chromatographic method. Changes to color, clarity, and pH were also monitored. There were no signs of chemical degradation of fentanyl packaged in polyolefin bags at either 5°C or 22°C after storage for 93 days. Over the course of the study, all solutions remained colorless and clear. The pH showed a slight decrease during the 93 days of storage. The stability of both undiluted (50-µg/mL) and diluted (10-µg/mL) fentanyl solutions when packaged in polyolefin bags was 93 days when stored at either 5°C or 22°C. Copyright© by International Journal of Pharmaceutical Compounding, Inc.
Cao, Qiongmin; Yuan, Guoan; Yin, Lijie; Chen, Dezhen; He, Pinjing; Wang, Hai
2016-12-01
In this research morphological techniques were used to characterize dechlorination process of PVC when it is in the mixed waste plastics and the two important factors influencing this process, namely, the proportion of PVC in the mixed plastics and heating rate adopted in the pyrolysis process were investigated. During the pyrolysis process for the mixed plastics containing PVC, the morphologic characteristics describing PVC dechlorination behaviors were obtained with help of a high-speed infrared camera and image processing tools. At the same time emission of hydrogen chloride (HCl) was detected to find out the start and termination of HCl release. The PVC contents in the mixed plastics varied from 0% to 12% in mass and the heating rate for PVC was changed from 10 to 60°C/min. The morphologic parameters including "bubble ratio" (BR) and "pixel area" (PA) were found to have obvious features matching with PVC dechlorination process therefore can be used to characterize dechlorination of PVC alone and in the mixed plastics. It has been also found that shape of HCl emission curve is independent of PVC proportions in the mixed plastics, but shifts to right side with elevated heating rate; and all of which can be quantitatively reflected in morphologic parameters vs. temperature curves. Copyright © 2016 Elsevier Ltd. All rights reserved.
Jaffee, B A
2004-09-01
Soil cages (polyvinyl chloride pipe with mesh-covered ends) were used to determine how the quantity of two organic amendments affected the nematode-trapping fungi Dactylellina haptotyla and Arthrobotrys oligospora, which were studied independently in two different vineyards. Each cage contained 80 cm(3) of field soil (120 g dry weight equivalent), fungal inoculum (two alginate pellets, each weighing 1.9 mg and containing assimilative hyphae of one fungus), and dried grape or alfalfa leaves (0, 360, or 720 mg equivalent to 0, 4,500, or 9,000 kg/ha) with a C:N of 28:1 and 8:1, respectively. Cages were buried in the vineyards, recovered after 25 to 39 days, and returned to the laboratory where fungus population density and trapping were quantified. Dactylellina haptotyla population density and trapping were most enhanced by the smaller quantity of alfalfa amendment and were not enhanced by the larger quantity of alfalfa amendment. Arthrobotrys oligospora population density was most enhanced by the larger quantity of alfalfa amendment, but A. oligospora trapped few or no nematodes, regardless of amendment. Trapping and population density were correlated for D. haptotyla but not for A. oligospora.
Thanh Truc, Nguyen Thi; Lee, Byeong-Kyu
2016-10-04
This study reports simple, selective, and sustainable separation of chlorinated plastic (polyvinyl chloride, PVC) and acrylonitrile butadiene styrene (ABS) containing brominated flame retardants (BFRs) from mixed waste electrical and electronic equipment (WEEE) plastics using microwave and/or mild-heat treatment. Microwave treatment after plastic coating with powdered activated carbon (PAC) selectively increased the hydrophilicity of the PVC surface, which facilitated PVC separation (100% recovery and purity) from the WEEE plastic mixture under the optimum flotation conditions. A further mild-heat treatment for 100 s facilitated selective separation with the highest recovery and purity (100%) of PAC-coated ABS containing BFRs from the remaining plastic mixture due to selective formation of a twisted structure with a lower density than water and the untreated ABS. Mild-heat treatment only of PAC-coated WEEE plastic mixture resulted in successful recovery of (100%) the ABS and PVC. However, the recovered PVC had slightly reduced purity (96.8%) as compared to that obtained using the combined heat and microwave treatments. The combination of both treatments with flotation facilitated selective and sustainable separation of PVC and ABS from WEEE plastics to improve their recycling quality.
NASA Astrophysics Data System (ADS)
Oshima, Keisuke; Inoue, Junta; Sadakata, Shifumi; Shiraishi, Yukihide; Toshima, Naoki
2017-05-01
Carbon nanotubes (CNTs) have recently received much attention as thermoelectric materials. Although the carrier mobility within a single CNT is very high, the charge carrier transport between CNTs is quite slow. We have utilized nanoparticles (NPs) for promotion of the carrier transport between CNTs for improving their thermoelectric performance. Poly(vinyl chloride) (PVC) was used as a binder of the CNTs. Thus, hybrid-type organic thermoelectric materials containing the NPs were constructed from Pd NPs, CNTs, and PVC. The thermoelectric properties were slightly improved in the three-component films by only mixing the separately-prepared Pd NPs. The NPs of a polymer complex, poly(nickel 1,1,2,2-ethenetetrathiolate) (n-PETT), were also used as a charge carrier transport promoter instead of the Pd NPs to produce n-PETT/CNT/PVC hybrid films. Treatment of the three-component films with methanol produced a high thermoelectric power factor and low thermal conductivity, resulting in a high "apparent" thermoelectric performance ( ZT ˜ 0.3 near room temperature) although the thermal conductivity was measured in the through-plane direction, which is a different direction from that for the electrical conductivity.
2011-03-01
Mile per hour ms Millisecond NEDU Navy Experimental Diving Unit PFD Personal flotation device PIW Person in the water PVC Polyvinyl chloride RDC...electrically resistive, yet conductive, clay. We then encapsulated the clay around a 1/2” diameter, 6-inch long copper rod, and then tightly wrapped it with...short length of 12 American Wire Gauge (AWG) stranded copper wire to the copper rod within each electrode. For each electrode pair, we joined
Barrow, C S; Lucia, H; Stock, M F; Alarie, Y
1979-05-01
The physiological stress imposed upon mice due to the irritating properties of thermal decomposition products of polymeric materials was evaluated. Acute lethality and histopathological evaluation were included in the study. The rankings of the polymeric materials studied from most to least hazardous was concluded to be polytetrafluoroethylene greater than polyvinyl chloride greater than Douglas Fir and flexible polyurethane foam greater than fiber glass reinforced polyester greater than copper coated wire with mineral insulation.
Remediation of DNAPL through Sequential In Situ Chemical Oxidation and Bioaugmentation
2009-04-01
Specific Electrode Field Field-filtered, ICP - PSC 0.05 mg/L 125 mL plastic nitric acid to pHɚ 28 days cool to 4oC Ion Chromatography 25310 C PSC 0.2...oxidized by MnO2 at a significant rate; however, MnO2 reacted rapidly with oxalic acid ; • Complete dechlorination occurred only in microcosms...controller PLFA phospholipid fatty acid ppb parts per billion PTA pilot test area PVC polyvinyl chloride QAPP quality assurance project plan QA
Polarization analysis of holographic gratings recorded in organic conductive material
NASA Astrophysics Data System (ADS)
Fontanilla-Urdaneta, R.; Hernández-Garay, M. P.; Olivares-Pérez, A.; Páez-Trujillo, G.; Fuentes-Tapia, I.
2007-09-01
This work presents experimental results of intensity changes by polarization conditions at the resultant diffraction patters. The substrate used as retarder plate was a commercial transparency film for use with plain paper copier (3M-PP2900 TM). The conductive material composition was introduce to dichromated poly(vinyl alcohol) by adding a metallic salt as nickel(II) chloride hexahydrate. Some electro-optical characteristics of organic conductive material that are used in the holographic gratings storage specifically when applied voltage.
Hansen, O Grøndahl
2008-10-01
Some hospitals in Europe still recommend medical devices that are not made from poly(vinyl chloride) (PVC) mainly because of environmental concerns. Yet, a brand new life cycle analysis that compares a medical device made from PVC with two devices made from alternative plastic materials shows that deselection of PVC is not advisable. This article reports on the latest scientific opinion on the possible risks related to the use of di(2-ethylhexyl) phthalate in medical devices and addresses some of the conclusions of the life cycle analysis.
A Study of the Effects of Insulation Gaps on Building Heat Loss
1980-04-01
the Guarded Hot Box. Figure 4, taken from ASTM C-236, shows the essential details of the Guarded Hot Box Test Apparatus. Details of the Johns - Manville Research...The walls are 1-3/- inches thick and are of sandwich construction, with a core of 2 pcf polyvinyl-chloride foam ( Johns - Manville Vinylcel) with faces...Council of Canada (NRC) ane at the Johns - Manville Research Center, was installed and tested as a wall. The test history of that pane] is shown in Table 3
The Mediterranean Plastic Soup: synthetic polymers in Mediterranean surface waters
Suaria, Giuseppe; Avio, Carlo G.; Mineo, Annabella; Lattin, Gwendolyn L.; Magaldi, Marcello G.; Belmonte, Genuario; Moore, Charles J.; Regoli, Francesco; Aliani, Stefano
2016-01-01
The Mediterranean Sea has been recently proposed as one of the most impacted regions of the world with regards to microplastics, however the polymeric composition of these floating particles is still largely unknown. Here we present the results of a large-scale survey of neustonic micro- and meso-plastics floating in Mediterranean waters, providing the first extensive characterization of their chemical identity as well as detailed information on their abundance and geographical distribution. All particles >700 μm collected in our samples were identified through FT-IR analysis (n = 4050 particles), shedding for the first time light on the polymeric diversity of this emerging pollutant. Sixteen different classes of synthetic materials were identified. Low-density polymers such as polyethylene and polypropylene were the most abundant compounds, followed by polyamides, plastic-based paints, polyvinyl chloride, polystyrene and polyvinyl alcohol. Less frequent polymers included polyethylene terephthalate, polyisoprene, poly(vinyl stearate), ethylene-vinyl acetate, polyepoxide, paraffin wax and polycaprolactone, a biodegradable polyester reported for the first time floating in off-shore waters. Geographical differences in sample composition were also observed, demonstrating sub-basin scale heterogeneity in plastics distribution and likely reflecting a complex interplay between pollution sources, sinks and residence times of different polymers at sea. PMID:27876837
Kozlov, Mikhail; McCarthy, Thomas J
2004-10-12
The adsorption of poly(vinyl alcohol) (PVOH) from aqueous solutions to a silicon-supported fluoroalkyl monolayer is described. Thickness, wettability, and roughness of adsorbed films are studied as a function of polymer molecular weight, degree of hydrolysis (from the precursor, poly(vinyl acetate)), polymer concentration, salt type and concentration, and temperature. The data suggest a two-stage process for adsorption of the polymer: physisorption due to a hydrophobic effect (decrease in interfacial free energy) and subsequent stabilization of the adsorbed layer due to crystallization of the polymer. Adsorption of lower-molecular-weight polymers results in thicker films than those prepared with a higher molecular weight; this is ascribed to better crystallization of more mobile short chains. Higher contents of unhydrolyzed acetate groups on the poly(vinyl alcohol) chain lead to thicker adsorbed films. Residual acetate groups partition to the outermost surface of the films and determine wettability. Salts, including sodium chloride and sodium sulfate, promote adsorption, which results in thicker films; at the same time, their presence over a wide concentration range leads to formation of rough coatings. Sodium thiocyanate has little effect on PVOH adsorption, only slightly reducing the thickness in a 2 M salt solution. Increased temperature promotes adsorption in the presence of salt, but has little effect on salt-free solutions. Evidently, higher temperatures favor adsorption but cause crystallization to be less thermodynamically favorable. These competing effects result in the smoothest coatings being formed in an intermediate temperature range. Copyright 2004 American Chemical Society
Gas Sensor Evaluations in Polymer Combustion Product Atmospheres
NASA Technical Reports Server (NTRS)
Delgado, Rafael H.; Davis, Dennis D.; Beeson, Harold D.
1999-01-01
Toxic gases produced by the combustion or thermo-oxidative degradation of materials such as wire insulation, foam, plastics, or electronic circuit boards in space shuttle or space station crew cabins may pose a significant hazard to the flight crew. Toxic gas sensors are routinely evaluated in pure gas standard mixtures, but the possible interferences from polymer combustion products are not routinely evaluated. The NASA White Sands Test Facility (WSTF) has developed a test system that provides atmospheres containing predetermined quantities of target gases combined with the coincidental combustion products of common spacecraft materials. The target gases are quantitated in real time by infrared (IR) spectroscopy and verified by grab samples. The sensor responses are recorded in real time and are compared to the IR and validation analyses. Target gases such as carbon monoxide, hydrogen cyanide, hydrogen chloride, and hydrogen fluoride can be generated by the combustion of poly(vinyl chloride), polyimide-fluoropolymer wire insulation, polyurethane foam, or electronic circuit board materials. The kinetics and product identifications for the combustion of the various materials were determined by thermogravimetric-IR spectroscopic studies. These data were then scaled to provide the required levels of target gases in the sensor evaluation system. Multisensor toxic gas monitors from two manufacturers were evaluated using this system. In general, the sensor responses satisfactorily tracked the real-time concentrations of toxic gases in a dynamic mixture. Interferences from a number of organic combustion products including acetaldehyde and bisphenol-A were minimal. Hydrogen bromide in the products of circuit board combustion registered as hydrogen chloride. The use of actual polymer combustion atmospheres for the evaluation of sensors can provide additional confidence in the reliability of the sensor response.
USDA-ARS?s Scientific Manuscript database
Whole air sampling using containers such as flexible bags or rigid canisters is commonly used to collect samples of volatile organic compounds (VOC) in air. The objective of this study was to compare the stability of polyester aluminum (PEA) and polyvinyl fluoride (PVF, brand name Tedlar®) bags for ...
A novel second-generation polyolefin container for storage of single-donor apheresis platelets.
Shimizu, T; Kouketsu, K; Kamiya, T; Futagawa, H; Hirose, S
1989-01-01
A non-blow-molded LE-2 polyolefin (PO) container was developed to store single-donor apheresis platelet concentrates (PCs) processed by the Haemonetics Plasma Collecting System (PCS) at 22 degrees C for over 1 day. We molded PO containers with heat-sealing of light-weight polymer alloy films with a thickness of 0.25 mm. The film was made of polymer blends consisting of polypropylene, styrene ethylene butylene styrene-block copolymer, and ethylene ethylacrylate copolymer. The PO container with enough strength and flexibility in routine practice has 2 and 1.6 times higher oxygen and carbon dioxide gas transfer properties than standard polyvinyl chloride (PVC) plastic containers. PCs (1-1.9 x 10(11) platelets) processed from 450 ml platelet-rich plasma were stored in 0.6-liter PO containers at 22 degrees C with flatbed agitation for up to 6 days. The pH of PCs was well maintained at the mean values of 7.0 in PO containers after 6 days in the well-oxygenated condition. The energy metabolism of stored platelets was determined. Oxygen consumption rates of platelets stored in PO containers averaged 1.5 nmol/min/10(9) platelets. The rates of glucose consumption and lactate production were 0.4 and 0.8 nmol/min/10(11) platelets, respectively. The rates of adenosine triphosphate (ATP) generation of platelets, 9.7 nmol/min/10(9) platelets, in PO containers did not differ from those in the PVC containers. Aggregation responses to adenosine diphosphate and hypotonic shock response of platelets were better maintained in PO containers. The morphological changes into sphere forms with projections and the appearance of unclassified forms were more frequently observed in PO than in PVC containers.(ABSTRACT TRUNCATED AT 250 WORDS)
Efficacy of heat treatment for disinfestation of concrete grain silos.
Opit, G P; Arthur, F H; Bonjour, E L; Jones, C L; Phillips, T W
2011-08-01
Field experiments were conducted in 2007 and 2008 to evaluate heat treatment for disinfestations of empty concrete elevator silos. A Mobile Heat Treatment Unit was used to introduce heat into silos to attain target conditions of 50 degrees C for at least 6 h. Ventilated plastic containers with a capacity of 100 g of wheat, Triticum aestivum L., held Rhyzopertha dominica (F.) (Coleoptera: Bostrichidae) and Tribolium castaneum (Herbst) (Coleoptera: Tenebrionidae). Polyvinyl chloride containers with a capacity of 300 g of wheat held adults of Liposcelis corrodens (Heymons) (Psocoptera: Liposcelididae) and Liposcelis decolor (Pearman), which were contained in 35-mm Petri dishes within the grain. Containers were fastened to a rope suspended from the top of the silo at depths of 0 m (just under the top manhole), 10 m, 20 m, and 30 m (silo floor). When the highest temperature achieved was approximately 50 degrees C for 6 h, parental mortality ofR. dominica and T. castaneum, and both psocid species was 98-100%. Progeny production of R. dominica occurred when there was parental survival, but in general R. dominica seemed less impacted by the heat treatment than T. castaneum. There was 100% mortality of L. corrodens at all depths in the heat treatments but only 92.5% mortality for L. decolor, with most survivors located in the bioassay containers at the top of the silo. Results show wheat kernels may have an insulating effect and heat treatment might be more effective when used in conjunction with sanitation and cleaning procedures.
Shelby, Michael D
2006-11-01
The National Toxicology Program (NTP) Center for the Evaluation of Risks to Human Reproduction (CERHR) conducted an updated evaluation of the potential for DEHP to cause adverse effects on reproduction and development in humans. The first CERHR expert panel evaluation of DEHP was completed in 2000 by the Phthalates Expert Panel. CERHR selected DEHP for an updated evaluation because of: (1) widespread human exposure, (2) public and government interest in adverse health effects, (3) recently available human exposure studies, and (4) the large number of relevant toxicity papers published since the earlier evaluation. DEHP (CAS RN: 117-81-7) is a high production volume chemical used as a plasticizer of polyvinyl chloride in the manufacture of a wide variety of consumer goods, such as building products, car products, clothing, food packaging, children's products (but not in toys intended for mouthing), and in medical devices made of polyvinyl chloride. The public can be exposed to DEHP by ingesting food, drink or dust that has been in contact with DEHP-containing materials, by inhaling contaminated air or dust, or by undergoing a medical procedure that uses polyvinyl chloride medical tubing or storage bags. It is estimated that the general population of the United States is exposed to DEHP levels ranging from 1 to 30 microg/kg bw/day (micrograms per kilogram body weight per day). The results of this DEHP update evaluation are published in an NTP-CERHR monograph that includes: (1) the NTP Brief, (2) the Expert Panel Update on the Reproductive and Developmental Toxicity of DEHP, and (3) public comments on the expert panel report. The NTP reached the following conclusions on the possible effects of exposure to DEHP on human development and reproduction. Note that the possible levels of concern, from lowest to highest, are negligible concern, minimal concern, some concern, concern, and serious concern. There is serious concern that certain intensive medical treatments of male infants may result in DEHP exposure levels that adversely affect development of the male reproductive tract. DEHP exposure from medical procedures in infants was estimated to be as high as 6000 microg/kg bw/day. There is concern for adverse effects on development of the reproductive tract in male offspring of pregnant and breast feeding women undergoing certain medical procedures that may result in exposure to high levels of DEHP. There is concern for effects of DEHP exposure on development of the male reproductive tract for infants less than one year old. Diet, mouthing of DEHP-containing objects, and certain medical treatments may lead to DEHP exposures that are higher than those experienced by the general population. There is some concern for effects of DEHP exposure on development of the reproductive tract of male children older than one year. As in infants, exposures of children to DEHP may be higher than in the general population. There is some concern for adverse effects of DEHP exposure on development of the male reproductive tract in male offspring of pregnant women not medically exposed to DEHP. Although DEHP exposures are assumed to be the same as for the general population, the developing male reproductive tract is sensitive to the adverse effects of DEHP. There is minimal concern for reproductive toxicity in adults exposed to DEHP at 1 - 30 microg/kg bw/day. This level of concern is not altered for adults medically exposed to DEHP. NTP will transmit the NTP-CERHR Monograph on DEHP to federal and state agencies, interested parties, and the public and it will be available in electronic PDF format on the CERHR web site http://cerhr.niehs.nih.gov and in printed text or CD-ROM from the CERHR.
NASA Astrophysics Data System (ADS)
Kim, Jin Kyu; Lee, Chang Soo; Lee, Sang-Yup; Cho, Hyung Hee; Kim, Jong Hak
2016-12-01
Bimodal porous TiO2 (BP-TiO2) with large surface area, high porosity, good interconnectivity, and excellent light-scattering ability are synthesized via a facile one-step method using a self-assembled blend template consisting of an amphiphilic poly(vinyl chloride)-g-poly(oxyethylene methacrylate) (PVC-g-POEM) graft copolymer and a hydrophobic poly(vinyl chloride) (PVC) homopolymer. The hydrophilically surface-modified TiO2 nanoparticles selectively interact with the hydrophilic POEM chains, while the addition of the PVC homopolymer increases the hydrophobic domain size, resulting in the formation of dual pores (i.e., macropores and mesopores). The sizes and numbers of macropores can easily be controlled by changing the molecular weight and amount of the PVC homopolymer. The polymer electrolyte dye-sensitized solar cells (DSSCs) fabricated with BP-TiO2 photoanodes exhibited energy conversion efficiencies of up to 7.6% at 100 mW cm-2, which is much higher than those of mesoporous TiO2 (5.8%) with PVC-g-POEM only and conventional nanocrystalline TiO2 (4.9%) with commercial Dyesol paste. The enhanced energy conversion efficiencies mostly resulted from the light-scattering effects of the macropores, which increased the light-harvesting efficiencies. The improved light-harvesting and photovoltaic performances of the DSSCs were characterized by UV-vis spectroscopy, incident photon-to-current conversion efficiency analysis, electrochemical impedance spectroscopy, intensity-modulated photocurrent spectroscopy, and intensity-modulated photovoltage spectroscopy.
Gonzalez, Dennis; Tjandraatmadja, Grace; Barry, Karen; Vanderzalm, Joanne; Kaksonen, Anna H; Dillon, Peter; Puzon, Geoff J; Sidhu, Jatinder; Wylie, Jason; Goodman, Nigel; Low, Jason
2016-11-15
The injection of stormwater into aquifers for storage and recovery during high water demand periods is a promising technology for augmenting conventional water reserves. Limited information exists regarding the potential impact of aquifer treated stormwater in distribution system infrastructure. This study describes a one year pilot distribution pipe network trial to determine the biofouling potential for cement, copper and polyvinyl chloride pipe materials exposed to stormwater stored in a limestone aquifer compared to an identical drinking water rig. Median alkalinity (123 mg/L) and colour (12 HU) in stormwater was significantly higher than in drinking water (82 mg/L and 1 HU) and pipe discolouration was more evident for stormwater samples. X-ray Diffraction and Fluorescence analyses confirmed this was driven by the presence of iron rich amorphous compounds in more thickly deposited sediments also consistent with significantly higher median levels of iron (∼0.56 mg/L) in stormwater compared to drinking water (∼0.17 mg/L). Water type did not influence biofilm development as determined by microbial density but faecal indicators were significantly higher for polyvinyl chloride and cement exposed to stormwater. Treatment to remove iron through aeration and filtration would reduce the potential for sediment accumulation. Operational and verification monitoring parameters to manage scaling, corrosion, colour, turbidity and microbial growth in recycled stormwater distribution networks are discussed. Crown Copyright © 2016. Published by Elsevier Ltd. All rights reserved.
Shao, Jing; Lu, KeQiao; Tian, Ge; Cui, YanYan; Yan, YuanYuan; Wang, TianMing; Zhang, XinLong; Wang, ChangZhong
2015-02-01
The assembly of a man-made gravity-supported free-flow biofilm incubator (GS-FFBI) was described, which was composed of a gas cushion injector and four incubators. The GS-FFBI had the characteristics of (i) a bottom-up flow direction, and (ii) lab-scale biofilm preparation without the use of a multichannel pump. Two opportunistic fungal strains, namely Candida albicans and Candida glabrata, were employed to incubate C. albicans and dual C. albicans-C. glabrata biofilms on the surface of medical-grade polyvinyl chloride perfusion tube. In terms of the results from {2, 3-bis (2-methoxy-4-nitro-5-sulfo-phenyl)-2H-tetrazolium-5-carboxanilide} (XTT) assay, dry weight measurement, colony-forming unit counting, susceptibility test, and scanning electron microscopy, it was demonstrated that GS-FFBI could form both stable single and dual Candida biofilms with no significant variations among the four incubators or the three daily incubations within 21h, and could operate for at least 96h smoothly with no contamination of stock medium. The results also indicated, for the first time, that C. albicans and C. glabrata might be co-existent competitively and symbiotically in the dual biofilms with flowing media. GS-FFBI would be a useful device to study in vitro morphological and physiological features of microbial biofilms in the medical settings. Copyright © 2014 Elsevier B.V. All rights reserved.
Yuan, G; Chen, D; Yin, L; Wang, Z; Zhao, L; Wang, J Y
2014-06-01
In this research a gas-liquid fluidized bed reactor was developed for removing chlorine (Cl) from polyvinyl chloride (PVC) to favor its pyrolysis treatment. In order to efficiently remove Cl within a limited time before extensive generation of hydrocarbon products, the gas-liquid fluidized bed reactor was running at 280-320 °C, where hot N2 was used as fluidizing gas to fluidize the molten polymer, letting the molten polymer contact well with N2 to release Cl in form of HCl. Experimental results showed that dechlorination efficiency is mainly temperature dependent and 300 °C is a proper reaction temperature for efficient dechlorination within a limited time duration and for prevention of extensive pyrolysis; under this temperature 99.5% of Cl removal efficiency can be obtained within reaction time around 1 min after melting is completed as the flow rate of N2 gas was set around 0.47-0.85 Nm(3) kg(-1) for the molten PVC. Larger N2 flow rate and additives in PVC would enhance HCl release but did not change the final dechlorination efficiency; and excessive N2 flow rate should be avoided for prevention of polymer entrainment. HCl is emitted from PVC granules or scraps at the mean time they started to melt and the melting stage should be taken into consideration when design the gas-liquid fluidized bed reactor for dechlorination. Copyright © 2013 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Guo, Jian-Wei; Lin, Zhen-Yu; Chang, Chi-Jung; Lu, Chien-Hsing; Chen, Jem-Kun
2018-05-01
In this study, poly(vinyl chloride) (PVC) was electrospun into fibrous membranes and then reacted with NaN3 to generate azido-terminated PVC fibrous membranes. A propargyl-terminated poly(N-isopropylacrylamide) (PNIPAAm) was also synthesized and then grafted, through click reactions, onto the azido-terminated PVC fiber surface. Protrusion-, scale-, and joint-like structures of the PNIPAAm grafts on the PVC fibers were formed upon increasing the molecular weight of the PNIPAAm grafts. The PNIPAAm-grafted PVC fibrous mats exhibited completely wetted surfaces at 25 °C because of their high roughness. The static water contact angle of the PNIPAAm-grafted PVC fibrous mats reached 140° when the temperature was increased to 45 °C. This thermoresponsive behavior was significantly greater than that of the PNIPAAm grafted on a flat surface. Temperature-responsive membranes were constructed having a pore size of 1.38 μm and applied as protein valves to block and release an antibody (fluorescein-conjugated AffiniPure goat anti-rabbit IgG). At 25 °C, the collection efficiency remained at 94% for antibody concentrations up to 60 ng/L. As the temperature increased to 45 °C, the collection efficiency decreased abruptly, to 4%, when the antibody concentration was greater than 20 ng/L. Accordingly, this system of PNIPAAm-grafted PVC fibers functioned as a protein valve allowing the capture and concentration of proteins.
Efficacy of disinfecting solutions in removing biofilms from polyvinyl chloride tracheostomy tubes.
Silva, Rodrigo C; Carver, Ryan A; Ojano-Dirain, Carolyn P; Antonelli, Patrick J
2013-01-01
Bacterial biofilms are prevalent in pediatric tracheostomy tubes (TTs) and are not completely cleared by standard cleaning with gauze and household detergents. We aimed to examine the effectiveness of different disinfecting solutions to remove Staphylococcus aureus (SA) and Pseudomonas aerginosa (PA) biofilms from TTs. Prospective, controlled, in vitro microbiologic study. Uniform coupons obtained from polyvinyl chloride (PVC) pediatric TTs were briefly exposed to human plasma. The samples were incubated in growth media with either PA or SA for 7 days, and total bacterial growth was monitored by media turbidity. Five sets of 18 coupons each were exposed for 5 minutes to one of five different solutions: 2% aqueous chlorhexidine gluconate solution, 0.3% aqueous sodium hypochlorite, Polident denture cleanser, 3% hydrogen peroxide, or preservative-free phosphate-buffered saline (PBS) as a negative control. Biofilm presence was measured with bacterial counts, and surface integrity was assessed with scanning electron microscopy (SEM). All treatments significantly reduced mean SA counts (P = <.001). Sodium hypochlorite and chlorhexidine were more effective than peroxide and Polident. Chlorhexidine, sodium hypochlorite, and peroxide reduced PA counts (P = .001, .001, and .002, respectively), but Polident tabs had no significant effect. SEM revealed preserved TT surface integrity after exposure to all solutions. Disinfection with sodium hypochlorite or chlorhexidine solutions significantly reduces SA and PA biofilms on PVC TTs. Standard home care of reusable pediatric TTs may be improved by use of these readily available solutions. Copyright © 2012 The American Laryngological, Rhinological, and Otological Society, Inc.
NASA Technical Reports Server (NTRS)
Kourtides, D. A.; Parker, J. A.; Hilado, C. J.
1977-01-01
The thermochemical and flammability characteristics of some typical thermoplastic materials currently in use or being considered for use in aircraft interiors are described. The properties studied included thermomechanical properties such as glass-transition and melt temperature, changes in polymer enthalpy, thermogravimetric analysis in anerobic and oxidative environments, oxygen index, smoke evolution, relative toxicity of the volatile products of pyrolysis, and selected physical properties. The generic polymers evaluated included acrylonitrile butadiene styrene, bisphenol A polycarbonate, 9,9 bis (4-hydroxyphenyl) fluorene polycarbonate-poly (dimethylsiloxane) block polymer, phenolphthalein-bisphenol A polycarbonate, phenolphthalein polycarbonate, polyether sulfone, polyphenylene oxide, polyphenylene sulfide, polyaryl sulfone, chlorinated polyvinyl chloride homopolymer, polyvinyl fluoride, and polyvinylidene fluoride. Processing parameters, including molding characteristics of some of the advanced polymers, are described. Test results and relative rankings of some of the flammability, smoke, and toxicity properties are presented. Under these test conditions, some of the advanced polymers evaluated were significantly less flammable and toxic than or equivalent to polymers in current use.
Kregiel, Dorota; Berlowska, Joanna; Mizerska, Urszula; Fortuniak, Witold; Chojnowski, Julian; Ambroziak, Wojciech
2013-07-01
Disease-causing bacteria of the genus Aeromonas are able to adhere to pipe materials, colonizing the surfaces and forming biofilms in water distribution systems. The aim of our research was to study how the modification of materials used commonly in the water industry can reduce bacterial cell attachment. Polyvinyl chloride and silicone elastomer surfaces were activated and modified with reactive organo-silanes by coupling or co-crosslinking silanes with the native material. Both the native and modified surfaces were tested using the bacterial strain Aeromonas hydrophila, which was isolated from the Polish water distribution system. The surface tension of both the native and modified surfaces was measured. To determine cell viability and bacterial adhesion two methods were used, namely plate count and luminometry. Results were expressed in colony-forming units (c.f.u.) and in relative light units (RLU) per cm(2). Almost all the chemically modified surfaces exhibited higher anti-adhesive and anti-microbial properties in comparison to the native surfaces. Among the modifying agents examined, poly[dimethylsiloxane-co-(N,N-dimethyl-N-n-octylammoniopropyl chloride) methylsiloxane)] terminated with hydroxydimethylsilyl groups (20 %) in silicone elastomer gave the most desirable results. The surface tension of this modifier, was comparable to the non-polar native surface. However, almost half of this value was due to the result of polar forces. In this case, in an adhesion analysis, only 1 RLU cm(-2) and less than 1 c.f.u. cm(-2) were noted. For the native gumosil, the results were 9,375 RLU cm(-2) and 2.5 × 10(8) c.f.u. cm(-2), respectively. The antibacterial activity of active organo-silanes was associated only with the carrier surface because no antibacterial compounds were detected in liquid culture media, in concentrations that were able to inhibit cell growth.
Ramesh, Sivalingam; Kim, Heung Soo; Lee, Young-Jun; Hong, Gwang-Wook; Kim, Joo-Hyung
2017-12-01
It is demonstrated in this paper that silica nanoparticles coated with core/shell gold provide efficient thermal, optical, and morphological properties with respect to the cellulose-polyhedral oligomeric silsesquioxanes (POSS) hybrid system. The one-step synthesis of a silica/gold nanocomposite is achieved with a simultaneous hydrolysis and reduction of gold chloride in the presence of formic acid, and the trimethoxysilane group acts as a silica precursor. The focus here comprises the synthesis of cellulose-POSS and silica/gold hybrid nanocomposites using the following two methods: (1) an in situ sol-gel process and (2) a polyvinyl alcohol/tetrakis (hydroxymethyl)phosphonium chloride process. Accordingly, the silica/gold core/shell nanoparticles are synthesized. The growth and attachment of the gold nanoparticles onto the functionalized surface of the silica at the nanometer scale is achieved via both the sol-gel and the tetrakis (hydroxymethyl) phosphonium chloride processes. The cellulose-POSS-silica/gold nanocomposites are characterized according to Fourier transformed infrared spectroscopy, Raman, X-ray diffraction, UV, photoluminescence, SEM, energy-dispersive X-ray spectroscopy, TEM, thermogravimetric, and Brunauer-Emmett-Teller analyses.
NASA Astrophysics Data System (ADS)
Ramesh, Sivalingam; Kim, Heung Soo; Lee, Young-June; Hong, Gwang-Wook; Kim, Joo-Hyung
2017-06-01
It is demonstrated in this paper that silica nanoparticles coated with core/shell gold provide efficient thermal, optical, and morphological properties with respect to the cellulose-polyhedral oligomeric silsesquioxanes (POSS) hybrid system. The one-step synthesis of a silica/gold nanocomposite is achieved with a simultaneous hydrolysis and reduction of gold chloride in the presence of formic acid, and the trimethoxysilane group acts as a silica precursor. The focus here comprises the synthesis of cellulose-POSS and silica/gold hybrid nanocomposites using the following two methods: (1) an in situ sol-gel process and (2) a polyvinyl alcohol/tetrakis (hydroxymethyl)phosphonium chloride process. Accordingly, the silica/gold core/shell nanoparticles are synthesized. The growth and attachment of the gold nanoparticles onto the functionalized surface of the silica at the nanometer scale is achieved via both the sol-gel and the tetrakis (hydroxymethyl) phosphonium chloride processes. The cellulose-POSS-silica/gold nanocomposites are characterized according to Fourier transformed infrared spectroscopy, Raman, X-ray diffraction, UV, photoluminescence, SEM, energy-dispersive X-ray spectroscopy, TEM, thermogravimetric, and Brunauer-Emmett-Teller analyses.
[Liver angiosarcoma from past exposure to vinyl chloride: a case report].
Di Lorenzo, L; Corfiati, Marisa; Catacchio, Teresa
2012-01-01
Experimental data and large occupational cohort studies in polyvinyl chloride (PVC) manufacturing plants have shown that vinyl chloride monomer (VCM) at high environmental concentrations, such as those measured in western chemical companies at least until the mid-1970's can cause liver angiosarcoma. To describe a recent, accurately diagnosed case of fatal liver angiosarcoma, for which it was possible to establish the causal relationship with past VCM exposure. The deceased subject had been working as blue-collar for at least eleven years (1968-1979) in a PVC plant. VCM exposure was high on average and very high during autoclave cleaning, compared with VCM air measurements reported in those years at plants in Europe and the United States. The latency period was about 40 years. The duration of exposure, the cumulative exposure and the latency described were similar to those associated in the scientific literature with an excess risk for liver angiosarcoma. The Italian Workers' Compensation Authority (INAIL) has already acknowledged the occupational origin of this neoplastic disease with clear advantages for all parties concerned, not only in economical terms.
Sensitive microplate assay for the detection of proteolytic enzymes using radiolabeled gelatin
DOE Office of Scientific and Technical Information (OSTI.GOV)
Robertson, B.D.; Kwan-Lim, G.E.; Maizels, R.M.
1988-07-01
A sensitive, microplate assay is described for the detection of a wide range of proteolytic enzymes, using radio-iodine-labeled gelatin as substrate. The technique uses the Bolton-Hunter reagent to label the substrate, which is then coated onto the wells of polyvinyl chloride microtiter plates. By measuring the radioactivity released the assay is able to detect elastase, trypsin, and collagenase in concentrations of 1 ng/ml or less, while the microtiter format permits multiple sample handling and minimizes sample volumes required for analysis.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nabeel, A.; Khan, T.A.; Sharma, D.K.
The kinetics of co-combustion/co-cracking of Topa coal with polystyrene, poly(vinyl chloride), and bakelite have been studied by theromogravimetric analysis at a linear heating rate of 20C/min in a stream of air for combustion and in nitrogen for cracking with a flow rate of 20 cm{sup 3}/min up to the temperature of 900C under non-isothermal conditions. The order of reaction and overall activation energy of the reactions have been calculated. These studies may help in synergistic production of value-added organic compounds and spatiality chemicals from coal and plastics.
2015-06-01
exposure settings…………………...26 Table 4. Kodak 9500 Cone Beam 3D System exposure settings…………..….27 Table 5. Average and statistical analysis results...42 Figure 6 Image of Mounted PVC Skull Model on the Kodak 9500……….…......43 Figure 7 Screen image of Reconstructed CBCT Digital...replica was taken with the Kodak 9500 Cone Beam 3D System. To create the digital dental models fifteen type IV maxillary dental casts were made on the
Dupuytren's contracture in manual workers.
Bennett, B
1982-01-01
The incidence of Dupuytren's contracture in a polyvinyl chloride (PVC) manufacturing plant, where a great deal of bagging and packing took place by hand, was higher than in another plant in which there was no bagging or packing. The incidence in the packing plant was double that found in an earlier survey by Early at Crewe Locomotive Works of 4801 individuals, most of whom were manual workers. The implication is that the nature of the work of bagging and packing in our PVC compounding plant may have triggered Dupuytren's contracture. PMID:7066227
Rugged Video System For Inspecting Animal Burrows
NASA Technical Reports Server (NTRS)
Triandafils, Dick; Maples, Art; Breininger, Dave
1992-01-01
Video system designed for examining interiors of burrows of gopher tortoises, 5 in. (13 cm) in diameter or greater, to depth of 18 ft. (about 5.5 m), includes video camera, video cassette recorder (VCR), television monitor, control unit, and power supply, all carried in backpack. Polyvinyl chloride (PVC) poles used to maneuver camera into (and out of) burrows, stiff enough to push camera into burrow, but flexible enough to bend around curves. Adult tortoises and other burrow inhabitants observable, young tortoises and such small animals as mice obscured by sand or debris.
Fréchette-Viens, Laurie; Hadioui, Madjid; Wilkinson, Kevin J
2017-01-15
The applicability of single particle ICP-MS (SP-ICP-MS) for the analysis of nanoparticle size distributions and the determination of particle numbers was evaluated using the rare earth oxide, La 2 O 3 , as a model particle. The composition of the storage containers, as well as the ICP-MS sample introduction system were found to significantly impact SP-ICP-MS analysis. While La 2 O 3 nanoparticles (La 2 O 3 NP) did not appear to interact strongly with sample containers, adsorptive losses of La 3+ (over 24h) were substantial (>72%) for fluorinated ethylene propylene bottles as opposed to polypropylene (<10%). Furthermore, each part of the sample introduction system (nebulizers made of perfluoroalkoxy alkane (PFA) or glass, PFA capillary tubing, and polyvinyl chloride (PVC) peristaltic pump tubing) contributed to La 3+ adsorptive losses. On the other hand, the presence of natural organic matter in the nanoparticle suspensions led to a decreased adsorptive loss in both the sample containers and the introduction system, suggesting that SP-ICP-MS may nonetheless be appropriate for NP analysis in environmental matrices. Coupling of an ion-exchange resin to the SP-ICP-MS led to more accurate determinations of the La 2 O 3 NP size distributions. Copyright © 2016 Elsevier B.V. All rights reserved.
Thailand's downstream projects proliferate
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1991-06-03
Thailand continues to press expansion and modernization of its downstream sector. Among recent developments: Construction of an olefins unit at Thailand's second major petrochemical complex and a worldscale aromatics unit in Thailand is threatened by rising costs. Thailand's National Petrochemical Corp (NPC) let a 9 billion yen contract to Mitsui Engineering and Shipbuilding Co. and C. Itoh and Co. for a dual fuel cogeneration power plant at its Mab Ta Phud, Rayong province, petrochemical complex. Financing is in place to flash a green light for a $530 million Belgian-Thai joint venture sponsoring a worldscale polyvinyl chloride/vinyl chloride monomer plant inmore » Thailand. Work is more than 50% complete on the $345 million second phase expansion of Thai Oil's Sri Racha refinery in Chon Buri province. Petroleum Authority of Thailand (PTT) endorsed a plan to install two more natural gas processing plants in Thailand to meet rapidly growing domestic demand for petroleum gas.« less
Decontaminating materials used in ground water sampling devices: Organic contaminants
DOE Office of Scientific and Technical Information (OSTI.GOV)
Parker, L.V.; Ranney, T.A.
2000-12-31
In these studies, the efficiency of various decontamination protocols was tested on small pieces of materials commonly used in ground water sampling devices. Three materials, which ranged in ability to sorb organic solutes, were tested: stainless steel (SS), rigid polyvinyl chloride (PVC), and polytetrafluoroethylene (PTFE). The test pieces were exposed to two aqueous test solutions: One contained three volatile organic compounds (VOCs) and one nitroaromatic compound, and the other contained four pesticides. Also, three types of polymetic tubing were exposed to pesticide solutions. Generally, the contact times were 10 minutes and 24 hours for sorption and desorption. The contaminants weremore » removed from the nonpermeable SS and the less-sorptive rigid PVC test pieces simply by washing with a hot detergent solution and rinsing with hot water. Additional treatment was required for the PTFE test pieces exposed to the VOCs and for the low-density polyethylene (LDPE) tubing exposed to the pesticide test solution. Solvent rinsing did not improve removal of the three VOCs form the PTFE and only marginally improved removal of the residual pesticides from the LDPE. However, a hot water and detergent wash and rinse followed by oven drying at approximately 105 C was effective for removing the VOCs from the PTFE and substantially reduced pesticide contamination from the LDPE.« less
Ohno, Hiroyuki; Suzuki, Masako; Nakashima, Shigehito; Aoyama, Taiki; Mitani, Kazunori
2002-08-01
A simultaneous determination method for 9 organotin compounds in polyvinyl chloride (PVC) and silicone products used as kitchen utensils and food packages was developed using ethyl derivatization with sodium tetraethylborate (NaBEt4). Organotin compounds were extracted with acetone-hexane (3:7) from the samples after acidification and the extract was filtered and concentrated at under 40 degrees C. After centrifugal separation, these compounds were derivatized with 2% NaBEt4 solution and determined by GC/MS. This method was applicable for simple routine analysis. Recoveries of spiked compounds were 49.1-118.1% for 3 PVC products and 88.8-102.2% for a siliconized paper. Monooctyltin, dioctyltin and trioctyltin compounds were found in all PVC food containers at the levels of 123-1,380 micrograms/g, 1,770-13,200 micrograms/g and 6.6-139 micrograms/g, respectively. They also were found in 3 gloves, 5 spouts, 1 hose and 5 pipes. Some PVC products contained monomethyltin, dimethyltin, trimethyltin, monobutyltin and dibutyltin compounds at the levels of 97.3-433 micrograms/g, 96.5-5,120 micrograms/g, 8.5-24.9 micrograms/g, 1.2-852 micrograms/g and 1.2-29.4 micrograms/g, respectively.
Okutani, Satoshi; Iwai, Takayoshi; Iwatani, Shintaro; Matsuno, Kiyoshi; Takahashi, Yasuhiro; Hase, Toshiharu
2015-09-01
During amino-acid crystal fermentation, mechanical stress on bacterial cells caused by crystal collision often impacts negatively on bacterial growth and amino-acid production. When Escherichia coli cells were cultivated under mechanical stress of polyvinyl chloride particles as a model of the crystal fermentation, activities of iron-sulfur (Fe-S) cluster-containing enzymes were apparently decreased. Based on an assumption that function of Fe-S cluster assembly machinery would be elevated to recover the enzyme activities in such stressed cells, we analyzed levels of various components of Fe-S cluster assembly machinery by western blotting. It was found that the expression of HscA, a chaperon component of the machinery, was up-regulated and that shorter forms of HscA with the N-terminal region truncated were accumulated, suggesting an important role of HscA against the mechanical stress. An overexpression of HscA gene in E. coli cells gave a positive effect on rescue of the stress-induced decrease of the activity of Fe-S cluster-containing enzyme. These results may provide a new strategy to alleviate the mechanical stress during the amino-acid crystal fermentation. Copyright © 2015 The Society for Biotechnology, Japan. Published by Elsevier B.V. All rights reserved.
Application of a TiO2 nanocomposite in earplugs, a case study of noise reduction.
Ibrahimi Ghavamabadi, Leila; Fouladi Dehaghi, Behzad; Hesampour, Morteza; Ahmadi Angali, Kambiz
2018-03-13
Use of hearing protection devices (HPDs) has become necessary when other control measures cannot reduce noise to a safe and standard level. In most countries, more effective hearing protection devices are in demand. The aim of this study was to examine the effects of titanium dioxide (TiO 2 ) nanoparticles on noise reduction efficiency in a polyvinyl chloride (PVC) earplug. An S-60 type PVC polymer as main matrix and TiO 2 with 30 nm size were used. PVC/TiO 2 nanocomposite was mixed at a temperature of 160 °C and 40 rounds per minute (rpm) and the samples were prepared with 0, 0.2 and 0.5 wt% of TiO 2 nanoparticle concentrations. Earplug samples with PVC/TiO 2 (0.2, 0.5 wt%) nanoparticles, when compared with raw earplugs, showed almost equal noise attenuation at low frequencies (500- 125 Hz). However, at high frequencies (2-8 kHz), the power of noise reduction of earplugs containing TiO 2 nanoparticles was significantly increased. The results of the present study showed that samples containing nanoparticles of TiO 2 had more noticeable noise reduction abilities at higher frequencies in comparison with samples without the nanoparticles.
Complex Coacervate Core Micelles Containing Poly(vinyl alcohol) Inhibit Ice Recrystallization.
Sproncken, Christian C M; Surís-Valls, Romà; Cingil, Hande E; Detrembleur, Christophe; Voets, Ilja K
2018-04-10
Complex coacervate core micelles (C3Ms) form upon complexation of oppositely charged copolymers. These co-assembled structures are widely investigated as promising building blocks for encapsulation, nanoparticle synthesis, multimodal imaging, and coating technology. Here, the impact on ice growth is investigated of C3Ms containing poly(vinyl alcohol), PVA, which is well known for its high ice recrystallization inhibition (IRI) activity. The PVA-based C3Ms are prepared upon co-assembly of poly(4-vinyl-N-methyl-pyridinium iodide) and poly(vinyl alcohol)-block-poly(acrylic acid). Their formation conditions, size, and performance as ice recrystallization inhibitors are studied. It is found that the C3Ms exhibit IRI activity at PVA monomer concentrations as low as 1 × 10 -3 m. The IRI efficacy of PVA-C3Ms is similar to that of linear PVA and PVA graft polymers, underlining the influence of vinyl alcohol monomer concentration rather than polymer architecture. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Kaewprachu, Pimonpan; Osako, Kazufumi; Benjakul, Soottawat; Rawdkuen, Saroat
2016-04-01
The effect of protein concentrations on the properties of fish myofibrillar protein film (FMP) were investigated and compared with commercial wrap film (polyvinyl chloride; PVC). FMP (2 %, w/v) showed the highest mechanical properties [tensile strength: 4.38 MPa and elongation at break: 133.05 %], and water vapor permeability [2.81 × 10(-10) g m(-1) s(-1) Pa(-1)]. FMP contained high molecular weight cross-links, resulting in complex film network, as indicated by lower film solubility (19-22 %) and protein solubility (0.6-1.3 %). FMP showed excellent barrier properties to UV light at the wavelength of 200-280 nm. FMP had the thickness [0.007-0.032 mm], color attributes and transparency similar to PVC film [thickness: 0.010 mm]. Therefore, protein concentration majority influenced the properties of develop FMP. The protein content of 1 % (w/v) had potential to be developed the biodegradable film with comparable properties to the commercial wrap film.
Bourdeaux, Daniel; Sautou-Miranda, Valérie; Bagel-Boithias, Sandrine; Boyer, Anne; Chopineau, Jean
2004-04-01
Di(2-ethylhexyl)phthalate (DEHP), a plasticiser present in infusion equipment, is known to be harmful to human health. Various studies have shown that DEHP is released into drug solutions from polyvinyl chloride (PVC) infusion lines. New multi-layer tubing has therefore been marketed to overcome this problem. We assessed the inertness of this tubing when placed in contact with a solution of CELLTOP. Chromatographic assay of DEHP showed no significant difference in DEHP levels in the solution when placed in contact with PVC and with multi-layer tubing. Analysis by infrared spectrometry showed that DEHP was initially present in the polyethylene layer of the multi-layer tubing even before contact with the drug solution. Contact with the solution results in release of DEHP from the container into the contents. The substance responsible for this release is in fact an excipient of CELLTOP, polysorbate. This release of DEHP further proves to depend on parameters such as temperature, time of contact between solution and tubing, and the concentration of polysorbate in the infused drug solution.
McCombie, Gregor; Biedermann, Sandra; Suter, Gaby; Biedermann, Maurus
2017-04-16
Plasticizers in toys are a recurring source of criticism and concern, as consumers feel they may endanger the health of their children. Most of the information available in literature concerns the presence or absence of certain phthalic acid ester plasticizers. Very little information can be found in the public domain with respect to the actually used plasticizers at a given time and place. In this paper, we present the plasticizer composition of 118 samples from 88 polyvinyl chloride toys found on the Swiss market in autumn 2015. Bis(2-ethylhexyl) terephthalate (DEHT) was by far the most frequent main plasticizer in the analyzed samples, which is a change when compared to the plasticizers found in toys and child care articles in 2007. Furthermore, the data show that the banned phthalates in toys are only a minor concern. The occurrence, however, is not evenly distributed between importers. If a toy is not designed to be sold on the European market by the manufacturer, it seems to be more likely to contain a banned phthalic acid ester.
Development of a field method for measuring manganese in welding fume.
Dale Marcy, A; Drake, Pamela L
2007-11-01
Workers who perform routine welding tasks are potentially exposed to fume that may contain manganese. Manganese may cause respiratory problems and is implicated in causing the occurrence of Parkinson-like symptoms. In this study, a field colorimetric method for extracting and measuring manganese in welding fume was developed. The method uses ultrasonic extraction with an acidic hydrogen peroxide solution to extract welding fume collected on polyvinyl chloride filters. Commercially available pre-packaged reagents are used to produce a colored solution, created by a reaction of manganese(ii) with 1-(2-pyridylazo)-2-naphthol. Absorbance measurements are then made using a portable spectrophotometer. The method detection limit and limit of quantification (LOQ) were 5.2 microg filter(-1) and 17 microg filter(-1), respectively, with a dynamic range up to 400 microg filter(-1). When the results are above the LOQ for the colorimetric method, the manganese masses are equivalent to those measured by the International Organization for Standardization Method 15202-2, which employs a strong acid digestion and analysis using inductively coupled plasma-optical emission spectrometry.
Jung, Melissa R.; Horgen, F. David; Orski, Sara V.; Rodriguez, Viviana; Beers, Kathryn L.; Balazs, George H.; Jones, T. Todd; Work, Thierry M.; Brignac, Kayla C.; Royer, Sarah-Jeanne; Hyrenbach, David K.; Jensen, Brenda A.; Lynch, Jennifer M.
2018-01-01
Polymer identification of plastic marine debris can help identify its sources, degradation, and fate. We optimized and validated a fast, simple, and accessible technique, attenuated total reflectance Fourier transform infrared spectroscopy (ATR FT-IR), to identify polymers contained in plastic ingested by sea turtles. Spectra of consumer good items with known resin identification codes #1–6 and several #7 plastics were compared to standard and raw manufactured polymers. High temperature size exclusion chromatography measurements confirmed ATR FT-IR could differentiate these polymers. High-density (HDPE) and low-density polyethylene (LDPE) discrimination is challenging but a clear step-by-step guide is provided that identified 78% of ingested PE samples. The optimal cleaning methods consisted of wiping ingested pieces with water or cutting. Of 828 ingested plastics pieces from 50 Pacific sea turtles, 96% were identified by ATR FT-IR as HDPE, LDPE, unknown PE, polypropylene (PP), PE and PP mixtures, polystyrene, polyvinyl chloride, and nylon.
Distribution of di(2-ethylhexyl) phthalate and products in blood and blood components.
Rock, G; Labow, R S; Tocchi, M
1986-01-01
In order to impart flexibility, plastic medical devices incorporate liquid plasticizers into their structure. Data from several laboratories, including ours, have shown that these compounds leach from blood bags and tubing during collection of blood, storage of various blood components and during kidney dialysis and cell and plasma apheresis procedures. After the plasticizer di(2-ethylhexyl) phthalate leaches from poly(vinyl chloride) blood packs, it is converted by a plasma enzyme to a more toxic metabolite, mono(2-ethylhexyl) phthalate. Blood fractionation products from outdated plasma contain mono(2-ethylhexyl) phthalate, the highest level being found in normal serum albumin. Recently, we have reported that di(2-ethylhexyl) phthalate actually binds to the red blood cell membrane and reduces its osmotic fragility. Current methods of red cells storage, which permit utilization up to 35 days after collection, are not possible without this membrane stabilization. Platelets are now stored for 5 days in the Fenwal PL 732 polyolefin bag. Although stated to be essentially free of liquid plasticizers, a significant level of leaching from this bag into the extracts of stored platelet concentrates was observed. PMID:3709456
Matsuba, Sota; Kato, Ryo; Okumura, Koichi; Sawada, Kazuaki; Hattori, Toshiaki
2018-01-01
In biochemistry, Ca 2+ and K + play essential roles to control signal transduction. Much interest has been focused on ion-imaging, which facilitates understanding of their ion flux dynamics. In this paper, we report a calcium and potassium multi-ion image sensor and its application to living cells (PC12). The multi-ion sensor had two selective plasticized poly(vinyl chloride) membranes containing ionophores. Each region on the sensor responded to only the corresponding ion. The multi-ion sensor has many advantages including not only label-free and real-time measurement but also simultaneous detection of Ca 2+ and K + . Cultured PC12 cells treated with nerve growth factor were prepared, and a practical observation for the cells was conducted with the sensor. After the PC12 cells were stimulated by acetylcholine, only the extracellular Ca 2+ concentration increased while there was no increase in the extracellular K + concentration. Through the practical observation, we demonstrated that the sensor was helpful for analyzing the cell events with changing Ca 2+ and/or K + concentration.
Weathering of oil (in Norwegian)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rosmanith, P.P.; Haegh, T.; Audunson, T.
Ekofisk crude oil (250 L) was exposed to weathering in Nov. 1977 contained in an oil boom on Trondheimsfjorden. Meteorologic and hydrographic data were recorded. Immediately after release of the oil, concentrations of up to 190 ppm of gas were measured 50 cm above the slick. In the water 20 cm below the oil, several parts per million of hydrocarbons was detected. Evaporation and solution of the oil was studied over a period of one month by gas chromatography. The loss of oil during this period was approximately 40%. Trials conducted with a polyvinyl chloride skimmer to study the adhesivemore » properties of the oil showed that the amount of oil recoverable by this method varied between 0.03 and 0.13 ml/sq cm. Microbiological investigations, phytoplankton growth, and growth rate measurements of Ascophyllum nodosum in oil/water mixtures also were made. The total number of bacteria in the polluted water increased by approximately 1000 times during 2 days following release of the oil. The phytoplankton were only slightly affected (75 cm below the slick), though A. nodosum showed a clear reduction in growth rate.« less
O'Connor, Isabel A; Golsteijn, Laura; Hendriks, A Jan
2016-12-15
Marine plastic debris are found worldwide in oceans and coastal areas. They degrade only slowly and contain chemicals added during manufacture or absorbed from the seawater. Therefore, they can pose a long-lasting contaminant source and potentially transfer chemicals to marine organisms when ingested. In order to assess their risk, the contaminant concentration in the plastics needs to be estimated and differences understood. We collected from literature plastic water partition coefficients of various organic chemicals for seven plastic types: polydimethylsiloxane (PDMS), high-density, low-density and ultra-high molecular weight polyethylene (LDPE, HDPE, UHMWPE), polystyrene (PS), polypropylene (PP), and polyvinyl chloride (PVC). Most data was available for PDMS (1060) and LDPE (220), but much less for the remaining plastics (73). Where possible, regression models were developed and the partitioning was compared between the different plastic types. The partitioning of chemicals follows the order of LDPE≈HDPE≥PP>PVC≈PS. Data describing the impact of weathering are urgently needed. Copyright © 2016 Elsevier Ltd. All rights reserved.
Gupta, Vinod K; Goyal, Rajendra N; Sharma, Ram A
2008-08-15
A potentiometric acetate-selective sensor, based on the use of butane-2,3-dione,bis[(2,4-dinitrophenyl)hydrazone] (BDH) as a neutral carrier in poly(vinyl chloride) (PVC) matrix, is reported. Effect of various plasticizers and cation excluder, cetryaltrimethylammonium bromide (CTAB) was studied. The best performance was obtained with a membrane composition of PVC:BDH:CTAB ratio (w/w; mg) of 160:8:8. The sensor exhibits significantly enhanced selectivity toward acetate ions over a wide concentration range 5.0 x 10(-6) to 1.0 x 10(-1)M with a lower detection limit of 1.2 x 10(-6)M within pH range 6.5-7.5 with a response time of <15s and a Nernstian slope of 60.3+/-0.3 mV decade(-1) of activity. Influences of the membrane composition, and possible interfering anions were investigated on the response properties of the electrode. Fast and stable response, good reproducibility and long-term stability are demonstrated. The sensor has a response time of 15s and can be used for at least 65 days without any considerable divergence in their potential response. Selectivity coefficients determined with the separate solution method (SSM) and fixed interference method (FIM) indicate that high selectivity for acetate ion. The proposed electrode shows fairly good discrimination of acetate from several inorganic and organic anions. It was successfully applied to direct determination of acetate within food preservatives. Total concentration of acetic acid in vinegar samples were determined by direct potentiometry and the values agreed with those mentioned by the manufacturers.
Wonoputri, Vita; Gunawan, Cindy; Liu, Sanly; Barraud, Nicolas; Yee, Lachlan H; Lim, May; Amal, Rose
2015-10-14
In this study, catalytic generation of nitric oxide by a copper(II) complex embedded within a poly(vinyl chloride) matrix in the presence of nitrite (source of nitric oxide) and ascorbic acid (reducing agent) was shown to effectively control the formation and dispersion of nitrifying bacteria biofilms. Amperometric measurements indicated increased and prolonged generation of nitric oxide with the addition of the copper complex when compared to that with nitrite and ascorbic acid alone. The effectiveness of the copper complex-nitrite-ascorbic acid system for biofilm control was quantified using protein analysis, which showed enhanced biofilm suppression when the copper complex was used in comparison to that with nitrite and ascorbic acid treatment alone. Confocal laser scanning microscopy (CLSM) and LIVE/DEAD staining revealed a reduction in cell surface coverage without a loss of viability with the copper complex and up to 5 mM of nitrite and ascorbic acid, suggesting that the nitric oxide generated from the system inhibits proliferation of the cells on surfaces. Induction of nitric oxide production by the copper complex system also triggered the dispersal of pre-established biofilms. However, the addition of a high concentration of nitrite and ascorbic acid to a pre-established biofilm induced bacterial membrane damage and strongly decreased the metabolic activity of planktonic and biofilm cells, as revealed by CLSM with LIVE/DEAD staining and intracellular adenosine triphosphate measurements, respectively. This study highlights the utility of the catalytic generation of nitric oxide for the long-term suppression and removal of nitrifying bacterial biofilms.
Wang, Chong-Qing; Wang, Hui; Huang, Luo-Luo
2017-07-01
A novel process was proposed for separation of ternary waste plastics by froth flotation. Pretreatment of plastics with potassium permanganate (KMnO 4 ) solution was conducted to aid flotation separation of polycarbonate (PC), polyvinyl chloride (PVC) and polymethyl methacrylate (PMMA) plastics. The effect of pretreatment parameters including KMnO 4 concentration, treatment time, temperature and stirring rate on flotation recovery were investigated by single factor experiments. Surface treatment with KMnO 4 changes selectively the flotation behavior of PC, PVC and PMMA, enabling separation of the plastics by froth flotation. Mechanism of surface treatment was studied by Fourier transform infrared spectroscopy (FTIR), scanning electron microscopy (SEM) and X-ray photoelectron spectrum (XPS). Effect of frother concentration and flotation time on flotation behavior of plastic mixtures was further studied for flotation separation. The optimized conditions for separation of PC are KMnO 4 concentration 2mmolL -1 , treatment time 10min, temperature 60°C, stirring rate 300rpm, flotation time 1min and frother concentration 17.5mgL -1 . Under optimum conditions, PVC and PMMA mixtures are also separated efficiently by froth flotation associated with KMnO 4 treatment. The purity of PC, PVC and PMMA is up to 100%, 98.41% and 98.68%, while the recovery reaches 96.82%, 98.71% and 98.38%, respectively. Economic analysis manifests remarkable profits of the developed process. Reusing KMnO 4 solution is feasible, enabling the process greener. Copyright © 2017 Elsevier Ltd. All rights reserved.
PLUTONIUM RECOVERY FROM NEUTRON-BOMBARDED URANIUM FUEL
Moore, R.H.
1962-04-10
A process of recovering plutonium from neutronbombarded uranium fuel by dissolving the fuel in equimolar aluminum chloride-potassium chloride; heating the mass to above 700 deg C for decomposition of plutonium tetrachloride to the trichloride; extracting the plutonium trichloride into a molten salt containing from 40 to 60 mole % of lithium chloride, from 15 to 40 mole % of sodium chloride, and from 0 to 40 mole % of potassium chloride or calcium chloride; and separating the layer of equimolar chlorides containing the uranium from the layer formed of the plutonium-containing salt is described. (AEC)
Fermentation of cucumbers brined with calcium chloride instead of sodium chloride
USDA-ARS?s Scientific Manuscript database
Generation of waste water containing sodium chloride from cucumber fermentation tank yards could be eliminated if cucumbers were fermented in brines that did not contain this salt. To determine if this is feasible, cucumbers were fermented in brines that contained only calcium chloride to maintain f...
Optimized Spectral Editing of 13C MAS NMR Spectra of Rigid Solids Using Cross-Polarization Methods
NASA Astrophysics Data System (ADS)
Sangill, R.; Rastrupandersen, N.; Bildsoe, H.; Jakobsen, H. J.; Nielsen, N. C.
Combinations of 13C magic-angle spinning (MAS) NMR experiments employing cross polarization (CP), cross polarization-depolarization (CPD), and cross polarization-depolarization-repolarization are analyzed quantitatively to derive simple and general procedures for optimized spectral editing of 13C CP/MAS NMR spectra of rigid solids by separation of the 13C resonances into CH n subspectra ( n = 0, 1, 2, and 3). Special attention is devoted to a differentiation by CPD/MAS of CH and CH 2 resonances since these groups behave quite similarly during spin lock under Hartmann-Hahn match and are therefore generally difficult to distinguish unambiguously. A general procedure for the design of subexperiments and linear combinations of their spectra to provide optimized signal-to-noise ratios for the edited subspectra is described. The technique is illustrated by a series of edited 13C CP/MAS spectra for a number of rigid solids ranging from simple organic compounds (sucrose and l-menthol) to complex pharmaceutical products (calcipotriol monohydrate and vitamin D 3) and polymers (polypropylene, polyvinyl alcohol, polyvinyl chloride, and polystyrene).
Method of processing aluminous ores
Loutfy, Raouf O.; Keller, Rudolf; Yao, Neng-Ping
1981-01-01
A method of producing aluminum chloride from aluminous materials containing compounds of iron, titanium and silicon comprising reacting the aluminous materials with carbon and a chlorine-containing gas at a temperature of about 900.degree. K. to form a gaseous mixture containing chlorides of aluminum, iron, titanium and silicon and oxides of carbon; cooling the gaseous mixture to a temperature of about 400.degree. K. or lower to condense the aluminum chlorides and iron chlorides while titanium chloride and silicon chloride remain in the gas phase to effect a separation thereof; heating the mixture of iron chlorides and aluminum chlorides to a temperature of about 800.degree. K. to form gaseous aluminum chlorides and iron chlorides; passing the heated gases into intimate contact with aluminum sulfide to precipitate solid iron sulfide and to form additional gaseous aluminum chlorides; and separating the gaseous aluminum chloride from the solid iron sulfide.
Li, Rui; Zhou, Jun; Liu, Hujun; Pei, Jianzhong
2017-01-01
Piezoelectric lead zirconatetitanate (PZT)/polymer composites were prepared by two typical polymer matrixes using the hot-press method. The micromorphology, microstructure, dielectric properties, and piezoelectric properties of the PZT/polymer composites were characterized and investigated. The results showed that when the condition of frequency is 103 Hz, the dielectric and piezoelectric properties of PZT/poly(vinylidene fluoride) were both better than that of PZT/polyvinyl chloride (PVC). When the volume fraction of PZT was 50%, PZT/PVDF prepared by the hot-press method had better comprehensive electric property. PMID:28805730
Fisher, B E
1999-01-01
From its creation to its disposal, there are environmental and health problems associated with polyvinyl chloride (vinyl), the major component of vinyl flooring. The production of vinyl creates toxic waste that must be dumped or incinerated. Because very little vinyl is recycled, the waste material must also be landfilled or burned. Furthermore, the heavy chlorine content of these materials result in the release of dioxins into the environment. A new flooring alternative to vinyl recently entered the market. Stratica, manufactured by Amtico Company Limited based in Coventry, United Kingdom, is made from polymer resins and offers the durability of vinyl without the environmental impact. PMID:10379015
NASA Astrophysics Data System (ADS)
Khan, F. A.; Yousaf, A.; Reindl, L. M.
2018-04-01
This paper presents a multi segment capacitive level monitoring sensor based on distributed E-fields approach Glocal. This approach has an advantage to analyze build-up problem by the local E-fields as well the fluid level monitoring by the global E-fields. The multi segment capacitive approach presented within this work addresses the main problem of unwanted parasitic capacitance generated from Copper (Cu) strips by applying active shielding concept. Polyvinyl chloride (PVC) is used for isolation and parafilm is used for creating artificial build-up on a CLS.
Acute urinary retention: which catheter?
Allardice, J. T.; Standfield, N. J.; Wyatt, A. P.
1988-01-01
There is no scientific data on which is the best method and catheter to use in acute urinary retention in males. We therefore compared the efficiency of a size 12 G latex rubber balloon catheter with a similar calibre but more expensive catheter made of polyvinyl-chloride (PVC). A total of 50 patients was studied and a 100% successful catheterisation rate was recorded at first attempt with both catheters, with no significant complications. The importance of the correct management of acute urinary retention, especially adequate analgesia, is stressed and it is concluded that either catheter is satisfactory. PMID:3207328
Fisher, B E
1999-07-01
From its creation to its disposal, there are environmental and health problems associated with polyvinyl chloride (vinyl), the major component of vinyl flooring. The production of vinyl creates toxic waste that must be dumped or incinerated. Because very little vinyl is recycled, the waste material must also be landfilled or burned. Furthermore, the heavy chlorine content of these materials result in the release of dioxins into the environment. A new flooring alternative to vinyl recently entered the market. Stratica, manufactured by Amtico Company Limited based in Coventry, United Kingdom, is made from polymer resins and offers the durability of vinyl without the environmental impact.
Adaptation of ion beam technology to microfabrication of solid state devices and transducers
NASA Technical Reports Server (NTRS)
Topich, J. A.
1978-01-01
A number of areas were investigated to determine the potential uses of ion beam techniques in the construction of solid state devices and transducers and the packaging of implantable electronics for biomedical applications. The five areas investigated during the past year were: (1) diode-like devices fabricated on textured silicon; (2) a photolithographic technique for patterning ion beam sputtered PVC (polyvinyl chloride); (3) use of sputtered Teflon as a protective coating for implantable pressure sensors; (4) the sputtering of Macor to seal implantable hybrid circuits; and (5) the use of sputtered Teflon to immobilize enzymes.
Jäppinen, A; Kokki, H; Naaranlahti, T J; Rasi, A S
1999-12-01
Combinations of opioids and adjuvant drug solutions are often used in clinical practice while little information is available on their microbiological or chemical stability. Currently there are no commercially available, prepacked, ready-to-use epidural or subcutaneous mixtures. Thus, epidural and subcutaneous analgesic mixtures must be prepared in the pharmacy on an as-needed basis. Such mixtures are typically used for the treatment of severe pain in cancer patients. The aim of this study was to investigate the microbiological and chemical stability of a buprenorphine, haloperidol and glycopyrrolate mixture in a 0.9% sodium chloride solution. A high performance liquid chromatographic (HPLC) method and pH-meter were used to conduct the analyses. Antimicrobial activity of each component was studied by an agar dilution method. According to the results from the chemical and microbiological stability studies, this mixture can be stored in polypropylene (PP) syringes and polyvinyl chloride (PVC) medication cassettes for at least 30 days at either 21 degrees C or 4 degrees C, and for 16 days in PP syringes at 36 degrees C, and for 9 days in PVC medication cassettes at 36 degrees C.
Hou, Li; Fan, Chunguang; Liu, Chenghu; Qu, Qiujin; Wang, Chunren
2018-01-01
Abstract Systemic toxicity caused by repeated exposure to both polar and nonpolar leachables of di(2-ethylhexyl)-1,2-cyclohexane plasticized polyvinyl chloride (PVC) was evaluated with dual routes of parenteral administration method on rats in the study. Experimental group and control group were designed by researchers. Tail intravenous injection with 0.9% sodium chloride injection extracts and intraperitoneal injection with corn oil extracts were conducted to the experimental rats while tail intravenous injection with 0.9% sodium chloride Injection and intraperitoneal injection with corn oil were conducted to the control rats. After 14 days, blood specimens were collected for clinical pathology (hematology and clinical chemistry) analysis. Selected organs were weighed and a histopathological examination was conducted. As a result, compared with the control animals, there were no toxicity-related changes on the parameters above. The results show that the rats do not show obvious systemic toxicity reaction caused by repeated exposure with dual routes of parenteral administration method on rats after administration with both polar and nonpolar exacts of di(2-ethylhexyl)-1,2-cyclohexane plasticized PVC simultaneously up for 14 days. PMID:29423263
Hatanaka, T; Imagawa, T; Kitajima, A; Takeuchi, M
2001-12-15
Combustion experiments in a laboratory-scale fluidized-bed reactor were performed to elucidate the effects of combustion temperature on PCDD/Fs formation during incineration of model wastes with poly(vinyl chloride) or sodium chloride as a chlorine source and copper chloride as a catalyst. Each temperature of primary and secondary combustion zones in the reactor was set independently to 700, 800, and 900 degrees C using external electric heaters. The PCDD/Fs concentration is reduced as the temperature of the secondary combustion zone increases. It is effective to keep the temperature of the secondary combustion zone high enough to reduce their release during the waste incineration. On the other hand, as the temperature of the primary combustion zone rises, the PCDD/Fs concentration also increases. Lower temperature of the primary combustion zone results in less PCDD/Fs concentration in these experimental conditions. This result is probably related to the devolatilization rate of the solid waste in the primary combustion zone. The temperature decrease slows the devolatilization rate and promotes mixing of oxygen and volatile matters from the solid waste. This contributes to completing combustion reactions, resulting in reducing the PCDD/Fs concentration.
Boeris, Valeria; Balce, Izabella; Vennapusa, Rami Reddy; Arévalo Rodríguez, Miguel; Picó, Guillermo; Lahore, Marcelo Fernández
2012-07-01
β-Galactosidase is a hydrolase enzyme that catalyzes the hydrolysis of β-galactosides into monosaccharides; its major application in the food industry is to reduce the content of lactose in lactic products. The aim of this work is to recover this enzyme from a cell lysate by adsorption onto Streamline-DEAE in an expanded bed, avoiding, as much as possible, biomass deposition onto the adsorbent matrix. So as to achieve less cell debris-matrix interaction, the adsorbent surface was covered with polyvinyl pyrrolidone. The enzyme showed to bind in the same extent to naked and covered Streamline-DEAE (65 mg β-gal/g matrix) in batch mode in the absence of any biomass. The kinetics of the adsorption process was studied and no effect of the polyvinyl pyrrolidone covering was found. The optimal conditions for the recovery were achieved by using a lysate made of 40% wet weight of cells, a polyvinyl pyrrolidone-covered matrix/lysate ratio of 10% and carrying out the adsorption process in expanded bed with recirculation over 2h in 20 mM phosphate buffer pH 7.4. The fraction recovered after the elution contained 65% of the initial amount of enzyme with a 12.6-fold increased specific activity with respect to the lysate. The polyvinyl pyrrolidone content in the eluate was determined and found negligible. The remarkable point of this work is that it was possible to partially purify the enzyme using a feedstock containing an unusually high biomass concentration in the presence of polyvinyl pyrrolidone onto weak anion exchangers. Copyright © 2012 Elsevier B.V. All rights reserved.
Amin, Mohd C I; Fell, John T
2004-01-01
Percolation theory has been used with great interest in understanding the design and characterization of dosage forms. In this study, work has been carried out to investigate the behavior of binary mixture tablets containing excipients of similar and different deformation properties. The binary mixture tablets were prepared by direct compression using lactose, polyvinyl chloride (PVC), Eudragit RS 100, and microcrystalline cellulose (MCC). The application of percolation theory on the relationships between compactibility, Pmax, or compression susceptibility (compressibility), gamma, and mixture compositions reveals the presence of percolation thresholds even for mixtures of similar deformation properties. The results showed that all mixture compositions exhibited at least one discreet change in the slope, which was referred to as the percolation threshold. The PVC/Eudragit RS100 mixture compositions showed significant percolation threshold at 80% (w/w) PVC loading. Two percolation thresholds were observed from a series of binary mixtures containing similar plastic deformation materials (PVC/MCC). The percolation thresholds were determined at 20% (w/w) and 80% (w/w) PVC loading. These are areas where one of the components percolates throughout the system and the properties of the tablets are expected to experience a sudden change. Experimental results, however, showed that total disruption of the tablet physical properties at the specified percolation thresholds can be observed for PVC/lactose mixtures at 20-30% (w/w) loading while only minor changes in the tablets' strength for PVC/MCC or PVC/Eudragit RS 100 mixtures were observed.
LeBlanc, Denis R.; Vroblesky, Don A.
2008-01-01
Laboratory and field tests were conducted at Camp Edwards on the Massachusetts Military Reservation on Cape Cod to examine the utility of passive diffusion sampling for long-term monitoring of concentrations of perchlorate and explosive compounds in ground water. The diffusion samplers were constructed of 1-inch-diameter rigid, porous polyethylene tubing. The results of laboratory tests in which diffusion samplers were submerged in containers filled with ground water containing perchlorate, RDX (hexahydro-1,3,5-trinitro-1,3,5-triazine), and HMX (octahydro-1,3,5,7-tetranitro-1,3,5,7-tetrazocine) indicate that concentrations inside the diffusion samplers equilibrated with concentrations in the containers within the 19-day-long test period. Field tests of the diffusion samplers were conducted in 15 wells constructed of 2- or 2.5-inch-diameter polyvinyl chloride pipe with 10-foot-long slotted screens. Concentrations of perchlorate, RDX, and HMX in the diffusion samplers placed in the wells for 42 to 52 days were compared to concentrations in samples collected by low-flow pumped sampling from 53 days before to 109 days after retrieval of the diffusion samples. The results of the field tests indicate generally good agreement between the pumped and diffusion samples for concentrations of perchlorate, RDX, and HMX. The concentration differences indicate no systematic bias related to contaminant type or concentration levels.
Legislation, control and research in the Nordic countries on plastics for packaging food.
Svensson, K
1994-01-01
The present legislation in the Nordic countries for food contact materials is expressed in general terms and contains few detailed requirements. At present Finland is implementing the EEC legislation, Sweden and Norway will probably do so shortly and Denmark has been a member of the EEC since 1973. Current food legislation in Sweden only covers materials or articles intended to come into contact with foodstuffs during processing or packaging in the food industry or by retailers. It does not apply to food packaging materials purchased for use at home or to household utensils. Upon request, the Toxicology Division at the Swedish National Food Administration (NFA) carries out evaluations of materials intended to come into contact with food. In addition, a voluntary organization--Normpack--is currently operating in Sweden. Normpack consists of manufacturers, dealers and users of food packaging materials, who have agreed to abide by certain common standards. In Norway, the Packaging Convention (Emballasjekonvensjonen--on safety of food packaging material from the health point view) serves a similar purpose. Research in this field is conducted at the National Food Agency of Denmark, The Danish Packaging and Transportation Research Institute (ETi) of the Danish Technological Institute (DTI), the Food Research Laboratory at the Technical Research Centre of Finland, MATFORSK, Norconserv and Statoil in Norway and the NFA, PackForsk and the Swedish Institute for Food Research (SIK) in Sweden. Previous studies have concerned plasticizers in PVC (polyvinyl chloride) cling film, overall migration studies on cling film, specific migration of vinyl chloride, styrene and acrylonitrile and off-flavours.(ABSTRACT TRUNCATED AT 250 WORDS)
Zhang, Lujia L; Cattrall, Robert W; Kolev, Spas D
2011-06-15
This paper reports the first use of a polymer inclusion membrane (PIM) for on-line separation in flow injection analysis (FIA) involving simultaneous extraction and back-extraction. The FIA system containing the PIM separation module was used for the determination of Zn(II) in aqueous samples in the presence of Mg(II), Ca(II), Cd(II), Co(II), Ni(II), Cu(II), and Fe(III). The Fe(III) and Cu(II) interferences were eliminated by off-line precipitation with phosphate and on-line complexation with chloride, respectively. The concentration of Zn(II) was determined spectrophotometrically using 4-(2-pyridylazo) resorcinol (PAR). The optimal composition of the PIM consisted of 40% (m/m) di(2-ethlyhexyl) phosphoric acid (D2EHPA) as carrier, 10% (m/m) dioctyl phthalate (DOP) as plasticizer and 50% (m/m) poly(vinyl chloride) (PVC) as the base polymer. The optimized FIA system was characterized by a linear calibration curve in the range from 1.0 to 30.0 mg L(-1) Zn(II), a detection limit of 0.05 mg L(-1) and a relative standard deviation of 3.4% with a sampling rate of 4h(-1). Reproducible results were obtained for 20 replicate injections over a 5h period which demonstrated a good membrane stability. The FIA system was applied to the determination of Zn(II) in pharmaceuticals and samples from the galvanizing industry and very good agreement with atomic absorption spectrometry was obtained. Copyright © 2011 Elsevier B.V. All rights reserved.
Polyvinyl chloride plastisol breast phantoms for ultrasound imaging.
de Carvalho, Isabela Miller; De Matheo, Lucas Lobianco; Costa Júnior, José Francisco Silva; Borba, Cecília de Melo; von Krüger, Marco Antonio; Infantosi, Antonio Fernando Catelli; Pereira, Wagner Coelho de Albuquerque
2016-08-01
Ultrasonic phantoms are objects that mimic some features of biological tissues, allowing the study of their interactions with ultrasound (US). In the diagnostic-imaging field, breast phantoms are an important tool for testing performance and optimizing US systems, as well as for training medical professionals. This paper describes the design and manufacture of breast lesions by using polyvinyl chloride plastisol (PVCP) as the base material. Among the materials available for this study, PVCP was shown to be stable, durable, and easy to handle. Furthermore, it is a nontoxic, nonpolluting, and low-cost material. The breast's glandular tissue (image background) was simulated by adding graphite powder with a concentration of 1% to the base material. Mixing PVCP and graphite powder in differing concentrations allows one to simulate lesions with different echogenicity patterns (anechoic, hypoechoic, and hyperechoic). From this mixture, phantom materials were obtained with speed of sound varying from 1379.3 to 1397.9ms(-1) and an attenuation coefficient having values between 0.29 and 0.94dBcm(-1) for a frequency of 1MHz at 24°C. A single layer of carnauba wax was added to the lesion surface in order to evaluate its applicability for imaging. The images of the phantoms were acquired using commercial ultrasound equipment; a specialist rated the images, elaborating diagnoses representative of both benign and malignant lesions. The results indicated that it was possible to easily create a phantom by using low-cost materials, readily available in the market and stable at room temperature, as the basis of ultrasonic phantoms that reproduce the image characteristics of fatty breast tissue and typical lesions of the breast. Copyright © 2016 Elsevier B.V. All rights reserved.
Zhang, Hong; Yang, Fengmin; Shen, Gang; Yang, Yueyang; Tang, Yalin
2015-05-01
Polyvinyl-chloride (PVC) with plasticizers of di(2-ethylhexyl) phthalate (DEHP) and tris(2-ethyl- hexyl) trimellitate (TOTM) is widely used in medical and paramedical appliances. However, such plasticizers can leach from PVC products into contact solutions. The aim of this study is to investigate the release behaviors of DEHP and TOTM from the PVC intravenous infusion set into various pharmaceutical solutions under the simulated clinical conditions, such as the lipophilic substances (paclitaxel) , parenteral nutrition (fat emulsion injection) , acid and alkali pharmaceutical solution (levofloxacin hydrochloride injection, pH 3.0-5.0 and furosemide, pH 8.0-9.0). A simple and rapid high-performance liquid chromatographic method with UV detection (HPLC-UV) for the determination of DEHP or TOTM released from PVC medical devices into the above intravenous preparations was developed. The cumulative amounts of DEHP or TOTM released in 24 h were in the same following order: paclitaxel > fat emulsion injection levofloxacin hydrochloride > furosemide solution. From a comparison of the cumulative amounts of released DEHP and TOTM from the above solutions, we found that the cumulative amount of TOTM is far less than that of DEHP, under the same conditions. The cumulative amount of the DEHP released in 24 h in the paclitaxel solution was 21. 14 mg, while under the same conditions, the cumulative amount of TOTM was only 0. 078 mg. The cumulative amount of DEHP is assumed to be about 270 times that of the released TOTM. Thus TOTM could be a superior alternative to DEHP for use in medical devices because of its potential lower leachability.
Evaluation of the Utility of Recycling Used Products made of Polyvinyl Chloride
NASA Astrophysics Data System (ADS)
Matsuda, Satoshi; Kubota, Hiroshi
This study intends to propose a new approach to evaluate the utility of recycling used products made of Polyvinyl Chloride (PVC) . In order to determine whether or not these used products can be recycled, there must be some indicators that appropriately and quantitatively show the degree that the contribution of recycling these targeted used products has on society. It was indicated that the rights and wrongs of incineration and/or heat recovery using a material such as wallpaper or floor cover made of PVC could be judged by the concept of "Social Energy Consumption" originally proposed by the authors (Chap. 3 in the text) . On the other hand, in the case where the used products such as PVC pipes and joints are dug out from underground and recycled, this research shows the estimation of its utility should be accomplished by extending the concept: Specifically, the manpower converted to the value of the social energy consumption was added, because labor costs for digging out these used products occupy a large portion of the total recycling cost, although manpower is not taken into account in the usual energy balance calculation, which leads to the contradiction of the estimation results from the standpoint of energy balance and economy. In this study, the marginal cost for digging out PVC pipes and joints evaluated by this method was shown as an example of a trial calculation (Chap. 2 in the text) . As a whole, this research quantitatively demonstrated an example trial calculation showing whether or not these used products should be recycled disregarding if the economic efficiency should be evaluated as a result of the analysis based upon the concept of "Social Energy Consumption".
Karlage, Kelly; Earhart, Zachary; Green-Boesen, Kelly; Myrdal, Paul B
2011-08-15
The stability of midazolam hydrochloride injection 1-mg/mL solutions in polyvinyl chloride (PVC) and polyolefin bags under varying conditions was evaluated. Triplicate solutions of midazolam hydrochloride 1-mg/mL were prepared in polyolefin and PVC i.v. bags by diluting midazolam hydrochloride injection 5 mg/mL with 5% dextrose injection. Bags were then stored under refrigeration (3-4 °C), exposed to light at room temperature (20-25 °C), or protected from light in amber bags at room temperature. Samples were taken immediately after preparation (day 0) and on days 1, 2, 3, 6, 13, 20, and 27 for analysis with a stability-indicating high-performance liquid chromatography assay in order to determine solution concentration. Stability was defined as retention of at least 90% of the initial drug concentration. The pH of each solution was also measured weekly. Sterility of the i.v. bags was determined at the end of the study by microbiological testing with culture in growth media. Differences in concentrations under the various storage conditions and bags used were analyzed using analysis of variance. All solutions retained over 98% of the initial midazolam hydrochloride concentration, with no statistically significant (p ≥ 0.05) change in concentration over the four-week period. Stability was not affected by temperature, exposure to light, or bag type. The pH of all solutions remained between 3.2 and 3.4 throughout the study. Sterility after 28 days was retained. Midazolam hydrochloride 1-mg/mL solutions diluted in 5% dextrose injection remained stable over 27 days in both polyolefin and PVC i.v. bags, regardless of storage condition.
Exposure to Bisphenol A and Other Phenols in Neonatal Intensive Care Unit Premature Infants
Calafat, Antonia M.; Weuve, Jennifer; Ye, Xiaoyun; Jia, Lily T.; Hu, Howard; Ringer, Steven; Huttner, Ken; Hauser, Russ
2009-01-01
Objective We previously demonstrated that exposure to polyvinyl chloride plastic medical devices containing di(2-ethylhexyl) phthalate (DEHP) was associated with higher urinary concentrations of several DEHP metabolites in 54 premature infants in two neonatal intensive care units than in the general population. For 42 of these infants, we evaluated urinary concentrations of several phenols, including bisphenol A (BPA), in association with the use of the same medical devices. Measurements We measured the urinary concentrations of free and total (free plus conjugated) species of BPA, triclosan, benzophenone-3, methyl paraben, and propyl paraben. Results The percentage of BPA present as its conjugated species was > 90% in more than three-quarters of the premature infants. Intensity of use of products containing DEHP was strongly associated with BPA total concentrations but not with any other phenol. Adjusting for institution and sex, BPA total concentrations among infants in the group of high use of DEHP-containing products were 8.75 times as high as among infants in the low use group (p < 0.0001). Similarly, after adjusting for sex and DEHP-containing product use category, BPA total concentrations among infants in Institution A were 16.6 times as high as those among infants in Institution B (p < 0.0001). Conclusion BPA geometric mean urinary concentration (30.3 μg/L) among premature infants undergoing intensive therapeutic medical interventions was one order of magnitude higher than that among the general population. Conjugated species were the primary urinary metabolites of BPA, suggesting that premature infants have some capacity to metabolize BPA. The differences in exposure to BPA by intensity of use of DEHP-containing medical products highlight the need for further studies to determine the specific source(s) of exposure to BPA. PMID:19440505
DOE Office of Scientific and Technical Information (OSTI.GOV)
Abd El-Kader, F.H.; Ibrahim, S.S.; Attia, G.
1993-11-15
The influence of neutron irradiation on ultraviolet/visible absorption and thermally stimulated depolarization current in nickel chloride-poly(vinyl alcohol) (PVA) cast films has been investigated. The spectral measurements indicate the responsibility of the Ni[sup 2][sup +] ion in its octahedral symmetry. Dopant concentrations higher than 10 wt % NiCl[sub 2] are found to make the samples more resistant to a degradation effect caused by neutron irradiation. The thermally stimulated depolarization currents (TSDC) of pure PVA revealed the existence of the glass transition T[sub g] and space charge relaxation peaks, whereas doped-PVA samples show a new sub-T[sub g] relaxation peak. A proposed mechanismmore » is introduced to account for the neutron effects on both glass transition and space charge relaxation peaks. The peak positions, peak currents, and stored charges of the sub-T[sub g] relaxation peak are strongly affected by both the concentration of the dopant and neutron exposure doses.« less
Ohno, Hiroyuki; Suzuki, Masako; Kawamura, Yoko
2011-01-01
The amount of evaporation residue was investigated as an index of total amount of non-volatile substances that migrated from plastic kitchen utensils into four food-simulating solvents (water, 4% acetic acid, 20% ethanol and heptane). The samples were 71 products made of 12 types of plastics for food contact use. The amount was determined in accordance with the Japanese testing method. The quantitation limit was 5 µg/mL. In the cases of polyethylene, polypropylene, polystyrene, acrylonitrile styrene resin, acrylonitrile butadiene styrene resin, polyvinyl chloride, polyvinylidene chloride, polymethylpentene, polymethylmethacrylate and polyethylene terephthalate samples, the amount was highest for heptane and very low for the other solvents. On the other hand, in the cases of melamine resin and polyamide samples, the amount was highest for 4% acetic acid or 20% ethanol and lowest for heptane. These results enabled the selection of the most suitable solvent, and the rapid and efficient determination of evaporation residue.
An in vitro bacterial adhesion assessment of surface-modified medical-grade PVC.
Asadinezhad, Ahmad; Novák, Igor; Lehocký, Marián; Sedlarík, Vladimir; Vesel, Alenka; Junkar, Ita; Sáha, Petr; Chodák, Ivan
2010-06-01
Medical-grade polyvinyl chloride was surface modified by a multistep physicochemical approach to improve bacterial adhesion prevention properties. This was fulfilled via surface activation by diffuse coplanar surface barrier discharge plasma followed by radical graft copolymerization of acrylic acid through surface-initiated pathway to render a structured high density brush. Three known antibacterial agents, bronopol, benzalkonium chloride, and chlorhexidine, were then individually coated onto functionalized surface to induce biological properties. Various modern surface probe techniques were employed to explore the effects of the modification steps. In vitro bacterial adhesion and biofilm formation assay was performed. Escherichia coli strain was found to be more susceptible to modifications rather than Staphylococcus aureus as up to 85% reduction in adherence degree of the former was observed upon treating with above antibacterial agents, while only chlorhexidine could retard the adhesion of the latter by 50%. Also, plasma treated and graft copolymerized samples were remarkably effective to diminish the adherence of E. coli. Copyright 2010 Elsevier B.V. All rights reserved.
Van Vliet, EDS; Reitano, EM; Chhabra, JS; Bergen, GP; Whyatt, RM
2012-01-01
Objective To conduct an extensive literature and toxicological database review on substitute compounds and available alternative medical products to replace polyvinyl chloride (PVC) and/or di(2-ethylhexyl) phthalate (DEHP), and conduct a DEHP-medical inventory analysis at a large metropolitan neonatal intensive care unit (NICU). Study Design A systematic search for DEHP-free alternative products was performed using online databases. An informal audit of a large metropolitan NICU was undertaken in 2005 and 2006; 21 products were identified that could potentially contain DEHP. Availability of DEHP-free alternatives was determined through company websites and phone interviews. Result Two alternative approaches are available for replacing DEHP in NICU medical products: (1) replacement by DEHP-free plasticizers; and (2) replacement of PVC entirely through the use of other polymers. Both approaches seem to provide less harmful substitutes to DEHP, but support PVC-free polymers as the preferred alternative. However, significant data gaps exist, particularly for the alternative polymers. In all, 10 out of 21 (48%) products in the NICU audit were DEHP-free; six consisted of alternative polymers and four of alternative plasticizers. Of the remaining 11 products, only three were available without DEHP at the time of the audit. Conclusion Because of significant data gaps, systematic toxicological testing of DEHP-free alternatives is imperative. Continued development of alternative products is also needed. PMID:21311501
SEM/EDS and optical microscopy analyses of microplastics in ocean trawl and fish guts.
Wang, Zhong-Min; Wagner, Jeff; Ghosal, Sutapa; Bedi, Gagandeep; Wall, Stephen
2017-12-15
Microplastic particles from Atlantic and Pacific Ocean trawls, lab-fed fish guts and ocean fish guts have been characterized using optical microscopy and SEM/EDS in terms of size, morphology, and chemistry. We assessed whether these measurements could serve as a rapid screening process for subsequent identification of the likely microplastic candidates by micro-spectroscopy. Optical microscopy enabled morphological classification of the types of particles or fibers present in the sample, as well as the quantification of particle size ranges and fiber lengths. SEM/EDS analysis was used to rule out non-plastic particles and screen the prepared samples for potential microplastic, based on their element signatures and surface characteristics. Chlorinated plastics such as polyvinyl chloride (PVC) could be easily identified with SEM/EDS due to their unique elemental signatures including chlorine, as could mineral species that are falsely identified as plastics by optical microscopy. Particle morphology determined by optical microscopy and SEM suggests the fish ingested particles contained both degradation fragments from larger plastic pieces and also manufactured microplastics. SEM images of microplastic particle surfaces revealed characteristic cracks consistent with environmental exposure, as well as pigment particles consistent with manufactured materials. Most of the microplastic surfaces in the fish guts and ocean trawls were covered with biofilms, radiolarians, and crustaceans. Many of the fish stomachs contained micro-shell pieces which visually resembled microplastics. Copyright © 2017 Elsevier B.V. All rights reserved.
Khan, Md. Rajibur Rahaman; Khalilian, Alireza; Kang, Shin-Won
2016-01-01
In this paper, we proposed an interdigitated capacitor (IDC)-based glucose biosensor to measure different concentrations of glucose from 1 μM to 1 M. We studied four different types of solvatochromic dyes: Auramine O, Nile red, Rhodamine B, and Reichardt’s dye (R-dye). These dyes were individually incorporated into a polymer [polyvinyl chloride (PVC)] and N,N-Dimethylacetamide (DMAC) solution to make the respective dielectric/sensing materials. To the best of our knowledge, we report for the first time an IDC glucose biosensing system utilizing a solvatochromic-dye-containing sensing membrane. These four dielectric or sensing materials were individually placed into the interdigitated electrode (IDE) by spin coating to make four IDC glucose biosensing elements. The proposed IDC glucose biosensor has a high sensing ability over a wide dynamic range and its sensitivity was about 23.32 mV/decade. It also has fast response and recovery times of approximately 7 s and 5 s, respectively, excellent reproducibility with a standard deviation of approximately 0.023, highly stable sensing performance, and real-time monitoring capabilities. The proposed IDC glucose biosensor was compared with an IDC, potentiometric, FET, and fiber-optic glucose sensor with respect to response time, dynamic range width, sensitivity, and linearity. We observed that the designed IDC glucose biosensor offered excellent performance. PMID:26907291
Treatment of iron(II)-rich acid mine water with limestone and oxygen.
Mohajane, G B; Maree, J P; Panichev, N
2014-01-01
The main components of acid mine water are free acid, sulphate, and Fe²⁺. Limestone is the most cost-effective alkali that can be used for neutralization. The purpose of this investigation was to identify conditions where Fe²⁺ is removed with limestone and simultaneously oxidized with oxygen to Fe³⁺, in a polyvinyl chloride pipe under pressure. Gypsum scaling is prevented by passing rubber balls through the pipe of the so-called Oxygen-Pipe-Neutralization (OPeN) process pilot plant. Two synthetic waters were treated: (A) acid mine water containing 123 mg L⁻¹ Fe²⁺ representing gold mine water, and (B) acid mine water containing 6,032 mg L⁻¹ Fe²⁺ representing coal mine water. Batch studies were carried out in a pipe reactor and showed that the rate of Fe²⁺ oxidation depended on the Fe²⁺ concentration, oxygen pressure, amount of recycled sludge, limestone dosage and the mixing rate. Continuous studies in an OPeN process pilot plant resulted in 100% removal of total acidity from synthetic coal mine water and a 98% removal from synthetic gold mine water. Fe²⁺ was removed completely as precipitated Fe(OH)₃ from both synthetic coal and gold mine water at around pH 7 at 200 and 100 kPa oxygen pressure, respectively.
Khan, Md Rajibur Rahaman; Khalilian, Alireza; Kang, Shin-Won
2016-02-20
In this paper, we proposed an interdigitated capacitor (IDC)-based glucose biosensor to measure different concentrations of glucose from 1 μM to 1 M. We studied four different types of solvatochromic dyes: Auramine O, Nile red, Rhodamine B, and Reichardt's dye (R-dye). These dyes were individually incorporated into a polymer [polyvinyl chloride (PVC)] and N,N-Dimethylacetamide (DMAC) solution to make the respective dielectric/sensing materials. To the best of our knowledge, we report for the first time an IDC glucose biosensing system utilizing a solvatochromic-dye-containing sensing membrane. These four dielectric or sensing materials were individually placed into the interdigitated electrode (IDE) by spin coating to make four IDC glucose biosensing elements. The proposed IDC glucose biosensor has a high sensing ability over a wide dynamic range and its sensitivity was about 23.32 mV/decade. It also has fast response and recovery times of approximately 7 s and 5 s, respectively, excellent reproducibility with a standard deviation of approximately 0.023, highly stable sensing performance, and real-time monitoring capabilities. The proposed IDC glucose biosensor was compared with an IDC, potentiometric, FET, and fiber-optic glucose sensor with respect to response time, dynamic range width, sensitivity, and linearity. We observed that the designed IDC glucose biosensor offered excellent performance.
Effect of PVC and iron materials on Mn(II) deposition in drinking water distribution systems.
Cerrato, José M; Reyes, Lourdes P; Alvarado, Carmen N; Dietrich, Andrea M
2006-08-01
Polyvinyl chloride (PVC) and iron pipe materials differentially impacted manganese deposition within a drinking water distribution system that experiences black water problems because it receives soluble manganese from a surface water reservoir that undergoes biogeochemical cycling of manganese. The water quality study was conducted in a section of the distribution system of Tegucigalpa, Honduras and evaluated the influence of iron and PVC pipe materials on the concentrations of soluble and particulate iron and manganese, and determined the composition of scales formed on PVC and iron pipes. As expected, total Fe concentrations were highest in water from iron pipes. Water samples obtained from PVC pipes showed higher total Mn concentrations and more black color than that obtained from iron pipes. Scanning electron microscopy demonstrated that manganese was incorporated into the iron tubercles and thus not readily dislodged from the pipes by water flow. The PVC pipes contained a thin surface scale consisting of white and brown layers of different chemical composition; the brown layer was in contact with the water and contained 6% manganese by weight. Mn composed a greater percentage by weight of the PVC scale than the iron pipe scale; the PVC scale was easily dislodged by flowing water. This research demonstrates that interactions between water and the infrastructure used for its supply affect the quality of the final drinking water.
Impregnated metal-polymeric functional beads
NASA Technical Reports Server (NTRS)
Rembaum, Alan (Inventor); Volksen, Willi (Inventor)
1980-01-01
Amine containing polymeric microspheres such as polyvinyl pyridine are complexed with metal salts or acids containing metals such as gold, platinum or iron. After reduction with sodium borohydride, the salt is reduced to finely divided free metal or metal oxides, useful as catalysts. Microspheres containing covalent bonding sites can be used for labeling or separating proteins.
Impregnated metal-polymeric functional beads
NASA Technical Reports Server (NTRS)
Rembaum, Alan (Inventor); Volksen, Willi (Inventor)
1978-01-01
Amine containing polymeric microspheres such as polyvinyl pyridine are complexed with metal salts or acids containing metals such as gold, platinum or iron. After reduction with sodium borohydride, the salt is reduced to finely divided free metal or metal oxides, useful as catalysts. Microspheres containing covalent bonding sites can be used for labeling or separating proteins.
Method for the regeneration of spent molten zinc chloride
Zielke, Clyde W.; Rosenhoover, William A.
1981-01-01
In a process for regenerating spent molten zinc chloride which has been used in the hydrocracking of coal or ash-containing polynuclear aromatic hydrocarbonaceous materials derived therefrom and which contains zinc chloride, zinc oxide, zinc oxide complexes and ash-containing carbonaceous residue, by incinerating the spent molten zinc chloride to vaporize the zinc chloride for subsequent condensation to produce a purified molten zinc chloride: an improvement comprising the use of clay in the incineration zone to suppress the vaporization of metals other than zinc. Optionally water is used in conjunction with the clay to further suppress the vaporization of metals other than zinc.
Dancing on coke: smuggling cocaine dispersed in polyvinyl alcohol.
van Nuijs, Alexander L N; Maudens, Kristof E; Lambert, Willy E; Van Calenbergh, Serge; Risseeuw, Martijn D P; Van hee, Paul; Covaci, Adrian; Neels, Hugo
2012-01-01
Recent trends suggest that cocaine smugglers have become more and more inventive to avoid seizures of large amounts of cocaine transported between countries. We report a case of a mail parcel containing a dance pad which was seized at the Customs Department of Brussels Airport, Belgium. After investigation, the inside of the dance pad was found to contain a thick polymer, which tested positive for cocaine. Analysis was performed using a routine colorimetric swipe test, gas chromatography coupled with mass spectrometry and nuclear magnetic resonance spectroscopy. The polymer was identified as polyvinyl alcohol (PVA) and contained 18% cocaine, corresponding to a street value of € 20,000. Laboratory experiments showed that cocaine could be easily extracted from the PVA matrix. This case report reveals a new smuggling technique for the transportation of large amounts of cocaine from one country to another. © 2011 American Academy of Forensic Sciences.
1981-05-20
broken and the material outgasses hydrogen. Halogenated polymers (e.g., Teflon or polyvinyl chloride) outgas the halogen or even yield the acid (e.g...the etching of the glass by HF. In other words, halogenated polymers when they are irradiated outgas acid vapors which are quite corrosive to any...Si~o S n 4~-1 -zi s -ic!et a:-:r su’i~ K :rs :c 3 xS I, :-aat, :.e ef-:n2 -n tc’ : "s-iacz on. a’ Iv-?g im :y’-,q st~c! y nay ze I :,.;es:*r:m I
Detection of explosive materials by differential reflection spectroscopy
NASA Astrophysics Data System (ADS)
Hummel, Rolf E.; Fuller, Anna M.; Schöllhorn, Claus; Holloway, Paul H.
2006-06-01
It is shown that traces of 2,4,6-trinitrotoluene (TNT) display strong and distinct structures in differential reflectograms, near 420 and 250nm. These characteristic peaks are not observed from moth balls, nail polish, polyvinyl chloride, starch, soap, paper, epoxy, aspirin, polycarbonate, aspartame, polystyrene, polyester, fertilizer, or sugar, to mention a few substances which may be in or on a suitcase. The described technique for detection of TNT is fast, inexpensive, reliable, and portable and does not require contact with the surveyed substance. Moreover, we have developed a curve recognition program for field applications of the technique. The origin of the spectra is discussed.
High-density polyethylene pipe: A new material for pass-by passive integrated transponder antennas
Kazyak, David C.; Zydlewski, Joseph D.
2012-01-01
Pass-by passive integrated transponder (PIT) antennas are widely used to study the movements of fish in streams. At many sites, stream conditions make it difficult to maintain antennas and obtain a continuous record of movement. We constructed pass-by PIT antennas by using high-density polyethylene (HDPE) and found them to be robust to high flows and winter ice flows. Costs for HDPE antennas were similar to those of traditional polyvinyl chloride (PVC) antennas, although construction was somewhat more complicated. At sites where PVC antennas are frequently damaged, HDPE is a durable and economical alternative for PIT antenna construction.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hyoungjin Kim
1993-03-03
In mid-February an eight-member Chinese delegation from the Ministry of Chemicals visited South Korea in search of petrochemicals joint venture partners. The delegation opened negotiations with Seoul-based Lucky (polyacetal resins, polymethacrylates, and polyvinyl chloride [PVC]); Hanyang Chemical (PVC); Samsung Petrochemical (aromatics); Korea Steel Chemical (carbon black); Il Shin Chemical (film for agricultural use); Shinsung Chemical (acrylonitrile butadiene styrene); Shin-A Chemical (expanded polystyrene). Meanwhile, Daelim (Seoul) is negotiating on a project to build 70,000-m.t./year octanol and butanol plants at Zhenjiang, China, plus shore tanks for its ethylene and propylene exports at Zhangbei and Liu Jiang. Daelim officials will visit China againmore » in May.« less
Metastatic angiosarcoma of the spleen after accidental radiation exposure: a case report.
Geffen, D B; Zirkin, H J; Mermershtain, W; Cohen, Y; Ariad, S
1998-04-01
Angiosarcoma is a rare malignant tumor arising from endothelial cells of blood vessels or lymphatic channels. Therapeutic irradiation, thoriumdioxide administration, pyothorax, and polyvinyl chloride exposure have been shown to be predisposing factors for developing angiosarcoma. Accidental radiation exposure has not been associated with angiosarcoma. We present an unusual case of angiosarcoma of the spleen, with metastases to bone, liver, breast, and bone marrow, in a woman who lived near the Chernobyl nuclear facility in the former Soviet Union at the time of the reactor accident in 1986. To the best of our knowledge, this is the first report of metastatic angiosarcoma after accidental radiation exposure.
Moriguchi, K; Ohno, N; Ogawa, T; Hirai, K
1999-01-01
When human polymorphonuclear leukocytes (PMN) were attached to glass coverslips, cells always spread and formed reactive oxygen species prior to any experimental stimulation. To avoid this, a polyvinylidine chloride film was used as an inactive substance to place the cells. Cells engaged in phagocytosis on the film exhibited a specific H2O2-mediated luminol chemiluminescence (LCL) at the cell-particle interface; the cells stimulated with 12-O-tetradecanoylphorbol-13-acetate became aggregated and the LCL was observed at the cell-cell contact. These results corresponded well with those obtained by an electron microscopic H2O2-demonstration method.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-08-17
... determined that Halflytely and Bisacodyl Tablets Bowel Prep Kit (polyethylene glycol (PEG) 3350, sodium chloride, sodium bicarbonate, and potassium chloride for oral solution and two bisacodyl delayed release... kits containing PEG-3350, sodium chloride, sodium bicarbonate, and potassium chloride for oral solution...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-03-19
... determined that HALFLYTELY AND BISACODYL TABLETS BOWEL PREP KIT (polyethylene glycol (PEG) 3350, sodium chloride, sodium bicarbonate, and potassium chloride for oral solution and 4 bisacodyl delayed release... kits containing PEG-3350, sodium chloride, sodium bicarbonate, and potassium chloride for oral solution...
[Identification of migrants from nitrile-butadiene rubber gloves].
Mutsuga, Motoh; Kawamura, Yoko; Wakui, Chiseko; Maitani, Tamio
2003-04-01
Polyvinyl chloride gloves containing di(2-ethylhexyl) phthalate are restricted for food contact use. In their place, disposable gloves made from nitrile-butadiene rubber (NBR) are used in contact with foodstuffs. Some unknown substances were found to migrate into n-heptane from NBR gloves. By GC/MS, HR-MS and NMR, their chemical structures were confirmed to be 2,2,4-trimethyl-1,3-pentanediol diisobutyrate (used as a plasticizer), 4,4'-butylidenedi(6-tert-butyl-m-cresol), a mixture of styrenated phenols consisting of 2-(alpha-methylbenzyl)phenol, 4-(alpha-methylbenzyl)phenol, 2,6-di(alpha-methylbenzyl)phenol, 2,4-di(alpha-methylbenzyl)phenol and 2,4,6-tri(alpha-methylbenzyl)phenol (used as antioxidants), and 2,4-di-tert-butylphenol, which seems to a degradation product of antioxidant. Migration levels of these compounds were 1.68 micrograms/cm2 of 2,4-di-tert-butylphenol, 2.80 micrograms/cm2 of 2,2,4-trimethyl-1,3-pentanediol diisobutyrate, 46.08 micrograms/cm2 of styrenated phenols and 4.22 micrograms/cm2 of 4,4'-butylidenedi(6-tert-butyl-m-cresol) into n-heptane, respectively. The content of total styrenated phenols was 6,900 micrograms/g in NBR gloves.
NASA Astrophysics Data System (ADS)
Zhang, Bin; Jiang, Yujie; Han, Jian
2017-12-01
The core-double-shell microcapsules flame retardant has been regarded as a promising additive for improving the fire safety of PVC. In this article, melamine-formaldehyde resin (MF)/silicon dioxide (SiO2)/zinc hydroxystannate (ZHS) microcapsule was prepared. The effect of synthetic parameters (such as pH, agitation speed, reaction time and reaction temperature) on the morphologies and sizes of the SiO2/ZHS microcapsules were investigated in details. MF/SiO2/ZHS microcapsule was introduced into PVC to prepare biofunctional composites with excellent fire resistance and smoke suppression. The flammability of PVC composites was characterized by limiting oxygen index (LOI), smoke density (SDR), cone calorimeter test. The results showed that the sample containing 16.4% MF/SiO2/ZHS microcapsule (the mass ratio of MF:SiO2:ZHS = 2.5:2:8) achieved the maximal LOI value of 35.6%, minimal SDR value of 21.2%, and significantly decreased the peak heat release rate from 179.7 kW/m2 of neat PVC to 108.3 kW/m2. The thermal behaviors of PVC composites and the morphologies of residues were characterized.
NASA Astrophysics Data System (ADS)
Divya Madhuri, U.; Kesava Rao, V.; Hariprasad, E.; Radhakrishnan, T. P.
2016-04-01
A simple protocol for the in situ generation of platinum nanoparticles in a poly(vinyl alcohol) (PVA) thin film is developed. Chloroplatinic acid as well as potassium platinum(II) chloride are used as precursors and the film is fabricated by spin coating followed by mild thermal annealing. The chemical process occurring inside the film, wherein the polymer itself acts as the reducing agent, is explored through different spectroscopy and microscopy techniques. The Pt-PVA film, <100 nm thick and containing ˜1 nm size Pt nanoparticles, is shown to be a highly efficient catalyst for the reduction of methylene blue using sodium borohydride. The ease of retrieval and reuse of the thin film is highlighted by the term ‘dip catalyst’. The reaction yield, kinetics and rate are reproducible through several reuses of the same catalyst film. Turnover number (TON = number of mols of product/number of mols of catalyst) and turnover frequency (TOF = TON/reaction time) are significantly higher than those reported earlier for this reaction using metal nanocatalysts. Utility of Pt-PVA film as an efficient catalyst for other hydrogenation reactions is demonstrated.
Jaakkola, J J; Oie, L; Nafstad, P; Botten, G; Samuelsen, S O; Magnus, P
1999-01-01
OBJECTIVES: This study assessed the role of polyvinyl chloride (PVC) plastics and textile materials in the home in the development of bronchial obstruction during the first 2 years of life. METHODS: The study was a matched pair case-control study based on a cohort of 3754 newborns in Oslo in 1992 and 1993 who were followed up for 2 years. The case group consisted of 251 children with bronchial obstruction; the control group was matched one-to-one for date of birth. RESULTS: In conditional logistic regression analysis, the risk of bronchial obstruction was related to the presence of PVC flooring (adjusted odds ratio [OR] = 1.89; 95% confidence interval [CI] = 1.14, 3.14) and textile wall materials (adjusted OR = 1.58; 95% CI = 0.98, 2.54). The reference category was wood or parquet flooring and painted walls and ceiling. Further analysis revealed an exposure-response relationship between the assessed amount of PVC and other plasticizer-containing surface materials and the risk of bronchial obstruction. CONCLUSIONS: This study provides new evidence of the role of PVC and textile wall materials in the development of bronchial obstruction in young children. PMID:9949747
Oxidative stability of cooked, frozen, reheated beef patties: effect of antioxidants.
Colindres, Paola; Brewer, M Susan
2011-03-30
The effect of selected antioxidants (grape seed extract (GS), oleoresin rosemary (OR), water-soluble oregano extract (WO), propyl gallate (PG), butylated hydroxyanisole (BHA)), butylated hydroxytoluene (BHT)) on sensory, color and oxidative stability of cooked, frozen, reheated ground beef patties was evaluated. Beef lean and trim were ground; antioxidants and salt were added. Patties were cooked (71 °C), overwrapped in commercial polyvinyl chloride film, and stored frozen (-18 °C), then evaluated monthly for 6 months. Flavor, odor and color were determined using a descriptive panel. Instrumental color was determined by a spectrocolorimeter. Lipid oxidation was determined using thiobarbituric acid reactive substances (TBARS). After 6 months of storage, PG and GS samples had lower rancid odor scores and TBARS than controls. Control samples and those containing BHT did not differ statistically in sensory grassy or rancid odor, indicating that they were the most oxidized. TBARS correlated with grassy, rancid, cardboard and beef odors during the 6-month storage period. Based on TBARS, the order of effectiveness of the antioxidants was PG and GS > OR > BHA > WO and BHT > control. TBARS were well correlated with sensory evaluations of odor and flavor. Antioxidants also protected a* values during storage. Copyright © 2011 Society of Chemical Industry.
Jaakkola, J J; Oie, L; Nafstad, P; Botten, G; Samuelsen, S O; Magnus, P
1999-02-01
This study assessed the role of polyvinyl chloride (PVC) plastics and textile materials in the home in the development of bronchial obstruction during the first 2 years of life. The study was a matched pair case-control study based on a cohort of 3754 newborns in Oslo in 1992 and 1993 who were followed up for 2 years. The case group consisted of 251 children with bronchial obstruction; the control group was matched one-to-one for date of birth. In conditional logistic regression analysis, the risk of bronchial obstruction was related to the presence of PVC flooring (adjusted odds ratio [OR] = 1.89; 95% confidence interval [CI] = 1.14, 3.14) and textile wall materials (adjusted OR = 1.58; 95% CI = 0.98, 2.54). The reference category was wood or parquet flooring and painted walls and ceiling. Further analysis revealed an exposure-response relationship between the assessed amount of PVC and other plasticizer-containing surface materials and the risk of bronchial obstruction. This study provides new evidence of the role of PVC and textile wall materials in the development of bronchial obstruction in young children.
Mutagenic substances in pyrolysate obtained by burning polyvinylchloride-product at 1000 degrees C.
Yonezawa, Y; Saigusa, S; Takahagi, M; Nishioka, H
1999-06-25
In order to detect possible mutagenic substances in pyrolysate obtained by burning polyvinyl chloride product (PVC-P) at approximately 1000 degrees C, mutagenicity of rough extracts obtained by extraction with various solvents for the products was investigated by means of reversion mutation assay using Salmonella typhimurium TA98 and TA100 with or without microsomal metabolic activation (S9 mix). Strong mutagenicity in TA98 without S9 mix was observed in acetone-extract of PVC-P. The extract was fractionated into acidic, neutral and basic by liquid-liquid distribution and the mutagenicity in TA98 without S9 mix was found in the neutral fraction. Identification of mutagenic substances in the neutral fraction from acetone extract, which showed the strongest mutagenicity, was attempted by means of thin layer chromatography and capillary gas chromatography. The results suggest that mutagenic substances from pyrolysate of PVC-P are benzanthrone and an isomer of benzo(c)cinnoline. The results also suggest that burning wastes containing plastic products is not always safe even if at 1000 degrees C and further research on the problem is necessary. Copyright 1999 Elsevier Science B.V.
NASA Astrophysics Data System (ADS)
Sabri, N. A.; Nawi, M. A.; Nawawi, W. I.
2015-10-01
Carbon coated nitrogen-doped Degussa P25TiO2 (or C,N-P25TiO2) was successfully immobilized on a glass plate using epoxidized natural rubber (ENR-50) and polyvinyl chloride (PVC) as the organic binders. Photo-etching of the fabricated system for 10 h oxidized its PVC binder into polyenes as well as forming a highly porous surface. The band gap energy (Eg) of the photo-etched immobilized photocatalyst system (C,N-P25TiO2/ENR/PVC-10 h) was reduced from 2.91 to 2.86 eV. Its photocatalytic activity was studied via photocatalytic degradation of 2,4-dichlorophenoxyacetic acid (2,4-D) under a 45 W visible light fluorescent lamp. C,N-P25TiO2/ENR/PVC-10 h with polyenes performed better than its slurry counterpart under visible light irradiation where the conjugated double bonds acted as photo sensitizers. The immobilized C,N-P25TiO2/ENR/PVC-10 h has excellent reusability and sustainable with an average k value of 0.056 ± 0.011 min-1 and average percent removal of 99.18 ± 0.54%.
Periportal fibrosis and other liver ultrasonography findings in vinyl chloride workers
Maroni, M; Mocci, F; Visentin, S; Preti, G; Fanetti, A
2003-01-01
Aims: To investigate the presence of liver lesions and their relation with vinyl chloride monomer (VCM) exposure or other personal risk factors, in workers involved in the production of VCM and polyvinyl chloride (PVC). Methods: A liver ultrasonography examination was conducted in 757 workers, some of whom had long standing service in the production of VCM and PVC. The study involved: assessment of individual past and present VCM exposure of each worker; collection of past personal health history, lifestyle and personal data; routine liver function tests; and liver ultrasonography. Results: No cases of liver malignancies were detected. Angiomas and liver cysts were found with a frequency of occurrence within the expected range of the general population. The main findings consisted of hepatomegaly (34.7%), steatosis (31.8%), and periportal fibrosis (16.0%). A logistic regression analysis indicated that hepatomegaly and steatosis were associated with obesity and lipid metabolism disturbances and not with VCM exposure. Periportal fibrosis, in addition to constitutional or dietary factors, was shown to be associated with VCM exposure, but only when maximum exposure in the subject's history had been at least 200 ppm as a yearly average; no effects were observed at 50 ppm or below. Conclusions: Workers exposed to 200 ppm VCM for at least one year have a fourfold increased risk of developing periportal liver fibrosis. Liver ultrasonography is a suitable and important diagnostic test for the medical surveillance of vinyl chloride workers. PMID:12499459
Chen, Kuo-Yu; Lin, Yu-Sheng; Yao, Chun-Hsu; Li, Ming-Hsien; Lin, Jui-Che
2010-01-01
2-[(acryloyloxy)ethyl]Trimethylammonium chloride (AETMAC) was grafted onto poly(vinyl alcohol) (PVA) using ceric ammonium nitrate (CAN) as a redox initiator. A series of graft co-polymer (PVA-g-PAETMAC) membranes with different contents of AETMAC were prepared with a casting method. The incorporation of AETMAC into PVA chains was confirmed by element analysis and Fourier transform infrared spectroscopy. The effects of grafting on the thermal properties, water take, water vapor transmission rate (WVTR), contact angle, antibacterial activity and cytotoxicity of PVA-g-PAETMAC membranes were investigated. The experiment results showed that PVA-g-PAETMAC membrane has a higher equilibrium swelling ratio, surface hydrophilicity and WVTR than pure PVA membrane. Moreover, the higher the content of AETMAC, the higher were equilibrium swelling ratio, surface hydrophilicity and WVTR. In vitro bacterial adhesion study demonstrated a significantly reduced number of Staphylococcus aureus and Escherichia coli on PVA-g-PAETMAC surfaces when compared to PVA surface. In addition, no significant difference in the in vitro cytotoxicity was observed between PVA and PVA-g-PAETMAC membranes. The presence of quaternary ammonium groups did not reduce L929 cell growth. Therefore, the PVA-g-PAETMAC membranes have the potential for wound-dressing application.
Sekhavat Pour, Zahra; Makvandi, Pooyan; Ghaemy, Mousa
2015-09-01
There has been a growing interest in developing antibacterial polymeric materials. In the present work, novel antibacterial cross-linked blend films were prepared based on polyvinyl alcohol (PVA) and quaternary ammonium starch (ST-GTMAC) using citric acid (CA) as plasticizer and glutaraldehyde (GA) as cross-linker. The ST-GTMAC was successfully synthesized from reaction between water-soluble oxidized starch and glycidyltrimethylammonium chloride (GTMAC). The effect of ST-GTMAC, CA and GA contents on the swelling, solubility, mechanical and thermal properties of the films was investigated. It was found that incorporation of ST-GTMAC reduced UV-transmittance and provided antibacterial properties, increasing GA content increased tensile strength and decreased solubility and swelling degree of the films, while CA acted as plasticizer when its concentration was above 10 wt%. The results showed that ST-GTMAC/PVA/CA/GA film has fair antibacterial activity against Gram-positive (Staphylococcus aureus and Bacillus subtilis) and Gram-negative (Escherichia coli and Pseudomonas aeruginosa) bacteria. These results suggest that the prepared film might be used as potential antibacterial material in medical and packaging applications. Copyright © 2015 Elsevier B.V. All rights reserved.
Wilkes, R A; Aristilde, L
2017-09-01
Synthetic plastics, which are widely present in materials of everyday use, are ubiquitous and slowly-degrading polymers in environmental wastes. Of special interest are the capabilities of microorganisms to accelerate their degradation. Members of the metabolically diverse genus Pseudomonas are of particular interest due to their capabilities to degrade and metabolize synthetic plastics. Pseudomonas species isolated from environmental matrices have been identified to degrade polyethylene, polypropylene, polyvinyl chloride, polystyrene, polyurethane, polyethylene terephthalate, polyethylene succinate, polyethylene glycol and polyvinyl alcohol at varying degrees of efficiency. Here, we present a review of the current knowledge on the factors that control the ability of Pseudomonas sp. to process these different plastic polymers and their by-products. These factors include cell surface attachment within biofilms, catalytic enzymes involved in oxidation or hydrolysis of the plastic polymer, metabolic pathways responsible for uptake and assimilation of plastic fragments and chemical factors that are advantageous or inhibitory to the biodegradation process. We also highlight future research directions required in order to harness fully the capabilities of Pseudomonas sp. in bioremediation strategies towards eliminating plastic wastes. © 2017 The Society for Applied Microbiology.
Raphael, Chenzira D; Zhao, Fang; Hughes, Susan E; Juba, Katherine M
2015-01-01
Levetiracetam is a commonly used antiepileptic medication for tumor-related epilepsy. However, the 100 mL intravenous (IV) infusion volume can be burdensome to imminently dying hospice patients. A reduced infusion volume would improve patient tolerability. The purpose of this study was to evaluate the stability of 1000 mg/25 mL (40 mg/mL) levetiracetam IV solution in sodium chloride 0.9%. We prepared levetiracetam 40 mg/mL IV solution and added it to polyvinyl chloride (PVC) bags, polyolefin bags, and polypropylene syringes. Triplicate samples of each product were stored at refrigeration (2-8°C) and analyzed on days 0, 1, 4, 7, and 14. Samples were subjected to visual inspection, pH measurement, and stability-indicating high-performance liquid chromatography (HPLC) analysis. Over the 2-week storage period, there was no significant change in visual appearance or pH for any of the stability samples. The HPLC results confirmed that all stability samples retained 94.2-101.3% of initial drug concentration and no degradation products or leachable material from the packaging materials were observed. We conclude that levetiracetam 1000 mg/25 mL IV solution in sodium chloride 0.9% is physically and chemically stable for up to 14 days under refrigeration in polypropylene syringes, PVC bags, and polyolefin bags.
Kim, Jin; Lee, Chang-Moon
2017-06-01
In this study, we investigated the effect of a polyvinyl alcohol-blended pectin hydrogel (PVA-PT HG) containing the extracts of Hippophae rhamnoides L. (H. rhamnoides L.) leaves on wound healing in a rat model. The total phenolic content in the extract solution was 40.64±2.7 GAE mg/g and that of flavonoids was 13.15±1.8 QE mg/g. Of the total flavonoids in HGs, 61.6 and 50.0% were released at pH 5.5 and 7.4 after 60min. In rat acute wound models, the wound size was reduced significantly and the recovery rate was significantly higher after treatment with HG containing the extracts, compared with treatment with the control and HG only. The wound healing effects of the HG containing the extracts were confirmed by histological evaluation of the wound tissue. Therefore, HG containing extracts from H. rhamnoides L. leaves enhanced wound healing effectively, and so may be developed as a cover to promote wound healing. Copyright © 2017 Elsevier B.V. All rights reserved.
Maphutha, Selby; Moothi, Kapil; Meyyappan, M.; Iyuke, Sunny E.
2013-01-01
A carbon nanotube (CNT) integrated polymer composite membrane with a polyvinyl alcohol barrier layer has been prepared to separate oil from water for treatment of oil-containing waste water. The CNTs were synthesised using chemical vapour deposition, and a phase inversion method was employed for the blending of the CNTs in the polymer composite solution for casting of the membrane. Relative to the baseline polymer, an increase of 119% in the tensile strength, 77% in the Young's modulus and 258% in the toughness is seen for a concentration of 7.5% CNTs in the polymer composite. The permeate through the membrane shows oil concentrations below the acceptable 10 mg/L limit with an excellent throughput and oil rejection of over 95%. PMID:23518875
Peper, Shane; Gonczy, Chad
2011-01-01
Csmore » + -selective solvent polymeric membrane-based ion-selective electrodes (ISEs) were developed by doping ethylene glycol-functionalized cross-linked polystyrene microspheres (P-EG) into a plasticized poly(vinyl chloride) (PVC) matrix containing sodium tetrakis-(3,5-bis(trifluoromethyl)phenyl) borate (TFPB) as the ion exchanger. A systematic study examining the effects of the membrane plasticizers bis(2-ethylhexyl) sebacate (DOS), 2-nitrophenyl octyl ether (NPOE), and 2-fluorophenyl nitrophenyl ether (FPNPE) on the potentiometric response and selectivity of the corresponding electrodes was performed. Under certain conditions, P-EG-based ion-selective electrodes (ISEs) containing TFPB and plasticized with NPOE exhibited a super-Nernstian response between 1 × 10 − 3 and 1 × 10 − 4 M + , a response characteristic not observed in analogous membranes plasticized with either DOS or FPNPE. Additionally, the performance of P-EG-based ISEs was compared to electrodes based on two mobile ionophores, a neutral lipophilic ethylene glycol derivative (ethylene glycol monooctadecyl ether (U-EG)) and a charged metallacarborane ionophore, sodium bis(dicarbollyl)cobaltate(III) (CC). In general, P-EG-based electrodes plasticized with FPNPE yielded the best performance, with a linear range from 10 -1 –10 -5 M + , a conventional lower detection limit of 8.1 × 10 − 6 M + , and a response slope of 57.7 mV/decade. The pH response of P-EG ISEs containing TFPB was evaluated for membranes plasticized with either NPOE or FPNPE. In both cases, the electrodes remained stable throughout the pH range 3–12, with only slight proton interference observed below pH 3.« less
Mikiciński, Artur; Sobiczewski, Piotr; Puławska, Joanna; Malusa, Eligio
2016-08-01
In a previous study (Mikiciński et al. in Eur J Plant Pathol, doi: 10.1007/s10658-015-0837-y , 2015), we described the characterization of novel strain 49M of Pseudomonas graminis, isolated from the phyllosphere of apple trees in Poland showing a good protective activity against fire blight on different organs of host plants. We now report investigations to clarify the basis for this activity. Strain 49M was found to produce siderophores on a medium containing complex CAS-Fe(3+) and HDTMA, but was not able to produce N-acyl homoserine lactones (AHLs). Moreover, it formed a biofilm on polystyrene and polyvinyl chloride (PVC) surfaces. Strain 49M gave a positive reaction in PCR with primers complementary to gacA, the regulatory gene influencing the production of several secondary metabolites including antibiotics. The genes prnD (encoding pyrrolnitrin), pltC, pltB (pyoluteorin), phlD (2,4-diacetyl-phloroglucinol) and phzC as well as phzD (and their homologs phzF and phzA encoding phenazine), described for antagonistic fluorescent pseudomonads, however, were not detected. Research into the biotic relationship between strain 49M and Erwinia amylovora strain Ea659 on five microbiological media showed that this strain clearly inhibited the growth of the pathogen on King's B and nutrient agar with glycerol media, to a very small extent on nutrient agar with sucrose, and not at all on Luria-Bertani agar. On medium 925, strain 49M even stimulated E. amylovora growth. The addition of ferric chloride to King's B resulted in the loss of its inhibitory ability. Testing the survival of 49M in vitro showed its resistance to drought, greater than that of E. amylovora.
Long-term stability of 5-fluorouracil stored in PVC bags and in ambulatory pump reservoirs.
Martel, P; Petit, I; Pinguet, F; Poujol, S; Astre, C; Fabbro, M
1996-02-01
Prolonged infusions of 5-fluorouracil (5FU) have been used since the early 1960s, but recently there has been a major resurgence of interest, partly because of the advent of electronically controlled portable infusion pumps. Admixtures of new formulation 5FU were subjected to stability studies to establish the feasability of continuous infusions. In the first study, the stability of 5FU, 1 or 10 mg ml(-1), was determined in poly(vinyl chloride) (PVC) bags (0.9% sodium chloride injection or 5% dextrose injection) at 4 and 21 degrees C after storage for 0, 1, 2, 3, 4, 7 and 14 days. In the second study, the stability of undiluted 5FU was tested at different temperatures (4 or 33 degrees C) in ethylene-vinyl acetate (EVA) or PVC ambulatory pump reservoirs after storage for 0, 3, 5, 7 and 14 days. For each condition, samples from each admixture were tested for drug concentration by stability-indicating high-performance liquid chromatography. The admixtures were also monitored for precipitation, colour change and pH. Evaporative water loss from the containers was measured. The stability of 5FU in PVC bags was unaffected by 14 days of storage at either 4 or 21 degrees C. When stored in EVA reservoirs, 5FU was stable for at least 2 weeks at 33 degrees C and for 3 days at 4 degrees C (a precipitate was observed after 3 days). In PVC reservoirs, 5FU was stable for over 14 days at 33 degrees C, but at 4 degrees C a precipitate appeared after 5 days. Loss of water through the reservoirs was substantial only at 33 degrees C for 14 days, and gave falsely high readings.
Pietrzak-Johnston, S M; Bishop, H; Wahlquist, S; Moura, H; Da Silva, N D; Da Silva, S P; Nguyen-Dinh, P
2000-05-01
Formalin and mercuric chloride-based low-viscosity polyvinyl alcohol (LV-PVA) are widely used by most diagnostic parasitology laboratories for preservation of helminth eggs and protozoan cysts and trophozoites in fecal specimens. Concerns about the toxicity of formalin and the difficulty of disposal of LV-PVA are powerful incentives to use alternate preservatives. Such alternatives have been marketed by several companies and are often presented as one-vial, non-mercuric chloride fixatives that aim at performing the same role as formalin and PVA combined. We compared five, one-vial commercial preservatives, two from Meridian Diagnostics, Inc. (Ecofix and sodium acetate-acetic acid-formalin), and one each from Scientific Device Laboratories, Inc. (Parasafe), Alpha Tec Systems, Inc. (Proto-fix), and Streck Laboratories, Inc. (STF), with 10% formalin and LV-PVA. Fecal specimens obtained from patients in a Brazilian hospital were aliquoted within 12 h of collection into the seven preservatives mentioned above and were processed after 1 month at the Centers for Disease Control and Prevention. Direct and concentrated permanent smears as well as concentrates for 20 positive specimens (a total of 259 processed samples) were prepared, stained according to the manufacturers' instructions, examined, and graded. Positive specimens contained one or more parasites with stages consisting of eggs, larvae, cysts, and a few trophozoites of Giardia intestinalis. Criteria for assessment of the preservatives included the quality of the diagnostic characteristics of helminth eggs, protozoan cysts, and trophozoites, ease of use, and cost. Acceptable alternatives to formalin for wet preparations were found. Ecofix was found to be comparable to the traditional "gold standard" LV-PVA for the visualization of protozoa in permanent stained smears. This study suggests that more acceptable alternatives to the traditional formalin and LV-PVA exist.
Polyvinyl alcohol-based nanocomposite hydrogels containing magnetic laponite RD to remove cadmium.
Mola Ali Abasiyan, Sara; Mahdavinia, Gholam Reza
2018-05-01
In this study, magnetic nanocomposite hydrogels based on polyvinyl alcohol were synthesized. Magnetic polyvinyl alcohol/laponite RD (PVA-mLap) nanocomposites were characterized by scanning electron microscopy, X-ray diffraction, transmission electron microscopy, and Fourier transform infrared spectroscopy. The results indicated that PVA-mLap had desirable magnetic-sorption properties and magnetic-laponite nanoparticles were successfully synthesized and added to polyvinyl alcohol. The present nanocomposites were applied to remove Cd 2+ from aqueous solution. The influence of initial Cd 2+ concentration, magnetic-laponite concentration, pH, and ionic strength on adsorption isotherm was investigated. Heterogeneity of adsorption sites was intensified by increasing magnetic concentration of adsorbents and by rising pH value. Results of ionic strength studies indicated that by increasing ionic strength more than four times, the adsorption of Cd 2+ has only decreased around 15%. According to the results, the dominant mechanism of Cd 2+ sorption by the present adsorbents was determined chemical and specific sorption. Therefore, the use of the present nanocomposites as a powerful adsorbent of Cd 2+ in the wastewater treatment is suggested. Isotherm data were described by using Freundlich and Langmuir models, and better fitting was introduced Langmuir model.
Congdon, Thomas R; Notman, Rebecca; Gibson, Matthew I
2016-09-12
Antifreeze (glyco) proteins are produced by many cold-acclimatized species to enable them to survive subzero temperatures. These proteins have multiple macroscopic effects on ice crystal growth which makes them appealing for low-temperature applications-from cellular cryopreservation to food storage. Poly(vinyl alcohol) has remarkable ice recrystallization inhibition activity, but its mode of action is uncertain as is the extent at which it can be incorporated into other high-order structures. Here the synthesis and characterization of well-defined block copolymers containing poly(vinyl alcohol) and poly(vinylpyrrolidone) by RAFT/MADIX polymerization is reported, as new antifreeze protein mimetics. The effect of adding a large second hydrophilic block is studied across a range of compositions, and it is found to be a passive component in ice recrystallization inhibition assays, enabling retention of all activity. In the extreme case, a block copolymer with only 10% poly(vinyl alcohol) was found to retain all activity, where statistical copolymers of PVA lose all activity with very minor changes to composition. These findings present a new method to increase the complexity of antifreeze protein mimetic materials, while retaining activity, and also to help understand the underlying mechanisms of action.
2016-01-01
Antifreeze (glyco) proteins are produced by many cold-acclimatized species to enable them to survive subzero temperatures. These proteins have multiple macroscopic effects on ice crystal growth which makes them appealing for low-temperature applications—from cellular cryopreservation to food storage. Poly(vinyl alcohol) has remarkable ice recrystallization inhibition activity, but its mode of action is uncertain as is the extent at which it can be incorporated into other high-order structures. Here the synthesis and characterization of well-defined block copolymers containing poly(vinyl alcohol) and poly(vinylpyrrolidone) by RAFT/MADIX polymerization is reported, as new antifreeze protein mimetics. The effect of adding a large second hydrophilic block is studied across a range of compositions, and it is found to be a passive component in ice recrystallization inhibition assays, enabling retention of all activity. In the extreme case, a block copolymer with only 10% poly(vinyl alcohol) was found to retain all activity, where statistical copolymers of PVA lose all activity with very minor changes to composition. These findings present a new method to increase the complexity of antifreeze protein mimetic materials, while retaining activity, and also to help understand the underlying mechanisms of action. PMID:27476873
Calcination process for radioactive wastes
Kilian, Douglas C.
1976-05-04
The present invention provides a method for minimizing the volatilization of chlorides during solidification in a fluidized-bed calciner of liquids containing sodium, nitrate and chloride ions. Zirconium and fluoride are introduced into the liquid, and one-half mole of calcium nitrate is added per mole of fluoride present in the liquid mixture. The mixture is calcined in the fluidized-bed calciner at about 500.degree.C., producing a high bulk density calcine product containing the chloride, thus tying up the chloride in the solid product and minimizing chloride volatilization.
Corrosion Inhibitors for Metals in Naval Environments
1988-06-15
chlorides (PCCOCl) were treated with an amino acid containing a long aliphatic chain (either li-aminoundecanoic acid or 6- aminocaproic acid ) to give the long...phthalocyanines as corrosion inhibiting coatings - poyeriz by decarboxylation of chloroiron (Il1) tetracarboxcyphthalocyanine and reacting the acid chloride...by converting the tetracarboxy- phthalocyanines to the corresponding acid chloride and reacting the acid chloride with amino acids containing 6 or 12
Weir, D C; Robertson, A S; Jones, S; Burge, P S
1989-01-01
Two cases of occupational asthma due to soft corrosive soldering fluxes used in metal jointing are described in which the diagnosis was based on work related deterioration in daily peak expiratory flow rate and positive responses in bronchial provocation tests. Both fluxes contained ammonium chloride and zinc chloride. Occupational asthma provoked by these agents has not previously been reported. PMID:2705153
Study of Swift Heavy Ion Modified Conducting Polymer Composites for Application as Gas Sensor
Srivastava, Alok; Singh, Virendra; Dhand, Chetna; Kaur, Manindar; Singh, Tejvir; Witte, Karin; Scherer, Ulrich W.
2006-01-01
A polyaniline-based conducting composite was prepared by oxidative polymerisation of aniline in a polyvinylchloride (PVC) matrix. The coherent free standing thin films of the composite were prepared by a solution casting method. The polyvinyl chloride-polyaniline composites exposed to 120 MeV ions of silicon with total ion fluence ranging from 1011 to 1013 ions/cm2, were observed to be more sensitive towards ammonia gas than the unirradiated composite. The response time of the irradiated composites was observed to be comparably shorter. We report for the first time the application of swift heavy ion modified insulating polymer conducting polymer (IPCP) composites for sensing of ammonia gas.
A new venous infusion path monitoring system utilizing electrostatic induced potential.
Ogawa, Hidekuni; Yonezawa, Yoshiharu; Maki, Hiromichi; Caldwell, W Morton
2008-01-01
A new venous infusion pathway monitoring system has been developed for hospital and home use. The system consists of linear and digital integrated circuits and a low-power 8-bit single chip microcomputer which constantly monitors the infusion pathway intactness. A 330 kHz AC voltage, which is induced on the patient's body by electrostatic coupling from a 330 kHz pulse oscillator, can be recorded by main and reference electrodes wrapped around the infusion polyvinyl chloride tube. If the injection needle or infusion tube becomes detached, then the system detects changes in the induced AC voltages and alerts the nursing station, via the nurse call system or PHS (personal handy phone system).
Phthalate-induced testicular dysgenesis syndrome: Leydig cell influence.
Hu, Guo-Xin; Lian, Qing-Quan; Ge, Ren-Shan; Hardy, Dianne O; Li, Xiao-Kun
2009-04-01
Phthalates, the most abundantly produced plasticizers, leach out from polyvinyl chloride plastics and disrupt androgen action. Male rats that are exposed to phthalates in utero develop symptoms characteristic of the human condition referred to as testicular dysgenesis syndrome (TDS). Environmental influences have been suspected to contribute to the increasing incidence of TDS in humans (i.e. cryptorchidism and hypospadias in newborn boys and testicular cancer and reduced sperm quality in adult males). In this review, we discuss the recent findings that prenatal exposure to phthalates affects Leydig cell function in the postnatal testis. This review also focuses on the recent progress in our understanding of how Leydig cell factors contribute to phthalate-mediated TDS.
Gamma radiation grafted polymers for immobilization of Brucella antigen in diagnostic test studies
NASA Astrophysics Data System (ADS)
Docters, E. H.; Smolko, E. E.; Suarez, C. E.
The radiation grafting process has a wide field of industrial applications, and in the recent years the immobilization of biocomponents in grafted polymeric materials obtained by means of ionizing radiations is a new and important contribution to biotechnology. In the present work, gamma preirradiation grafting method was employed to produce acrylics hydrogels onto polyethylene (PE), polyvinyl chloride (PVC) and polystyrene (PS). Two monomers were used to graft the previously mentioned polymers: methacrylic acid (MAAc) and acrylamide (AAm), and several working conditions were considered as influencing the degree of grafting. All this grafted polymers were used to study the possibility of a subsequent immobilization of Brucella antigen (BAg) in diagnostic test studies (ELISA).
Infusion of di-2-ethylhexylphthalate for neonates: a review of potential health risk.
Jaeger, Rudolph J; Weiss, Arlene L; Brown, Karen
2005-01-01
Plasticizers leach from polyvinyl chloride medical devices into infusion fluids. One plasticizer frequently found is di-2-ethylhexylphthalate. The Food and Drug Administration estimates that di-2-ethylhexylphthalate exposure exceeding a daily tolerable intake of 0.6 mg/kg per day may harm newborns, especially males. Exposure 20 times the tolerable intake or more may be given daily to certain infants, neonates, and premature infants in the neonatal intensive care unit. Currently, scant data exist on the exact dosage to this population. Furthermore, the exact potential for harm, either subtle or overt, is unknown or disputed. Thus, the recording of exposure history and "dose" in the medical record is warranted.
Barker, Charles E.; Dallegge, Todd A.; Clark, Arthur C.
2002-01-01
We have updated a simple polyvinyl chloride plastic canister design by adding internal headspace temperature measurement, and redesigned it so it is made with mostly off-the-shelf components for ease of construction. Using self-closing quick connects, this basic canister is mated to a zero-head manometer to make a simple coalbed methane desorption system that is easily transported in small aircraft to remote localities. This equipment is used to gather timed measurements of pressure, volume and temperature data that are corrected to standard pressure and temperature (STP) and graphically analyzed using an Excel(tm)-based spreadsheet. Used together these elements form an effective, practical canister desorption method.
Polishing compound for plastic surfaces
Stowell, M.S.
1991-01-01
This invention is comprised of a polishing compound for plastic materials. The compound includes approximately by approximately by weight 25 to 80 parts at least one petroleum distillate lubricant, 1 to 12 parts mineral spirits, 50 to 155 parts abrasive paste, and 15 to 60 parts water. Preferably, the compound includes approximately 37 to 42 parts at least one petroleum distillate lubricant, up to 8 parts mineral spirits, 95 to 110 parts abrasive paste, and 50 to 55 parts water. The proportions of the ingredients are varied in accordance with the particular application. The compound is used on PLEXIGLAS{trademark}, LEXAN{trademark}, LUCITE{trademark}, polyvinyl chloride (PVC), and similar plastic materials whenever a smooth, clear polished surface is desired.
Aydın, Ahmet Alper; Ilberg, Vladimir
2016-01-20
A series of gelatinized polyvinyl alcohol (PVA):starch blends were prepared with various polyol-based plasticizers in 5 wt%, 15 wt% and 25 wt% ratios via solution casting method. The obtained films were analyzed by Fourier transform infrared (FT-IR) spectroscopy, differential scanning calorimetry (DSC) and thermogravimetric analysis (TGA). Remarkable changes have been observed in glass-transition temperature (Tg) and thermal stability of the samples containing varying concentrations of different plasticizers and they have been discussed in detail with respect to the conducted thermal and chemical analyses. The observed order of Tg point depression of the samples containing 15 wt% plasticizer is 1,4-butanediol - 1,2,6-hexanetriol--pentaerythriyol--xylitol--mannitol, which is similar to the sequence of the thermal stability changes of the samples. Copyright © 2015 Elsevier Ltd. All rights reserved.
Zhang, Ri-Chao; Sun, Dan; Lu, Ai; Askari, Sadegh; Macias-Montero, Manuel; Joseph, Paul; Dixon, Dorian; Ostrikov, Kostya; Maguire, Paul; Mariotti, Davide
2016-06-01
This Research Article reports on the enhancement of the thermal transport properties of nanocomposite materials containing hexagonal boron nitride in poly(vinyl alcohol) through room-temperature atmospheric pressure direct-current microplasma processing. Results show that the microplasma treatment leads to exfoliation of the hexagonal boron nitride in isopropyl alcohol, reducing the number of stacks from >30 to a few or single layers. The thermal diffusivity of the resulting nanocomposites reaches 8.5 mm(2) s(-1), 50 times greater than blank poly(vinyl alcohol) and twice that of nanocomposites containing nonplasma treated boron nitride nanosheets. From TEM analysis, we observe much less aggregation of the nanosheets after plasma processing along with indications of an amorphous carbon interfacial layer, which may contribute to stable dispersion of boron nitride nanosheets in the resulting plasma treated colloids.
NASA Astrophysics Data System (ADS)
Peng, Sha; Zhou, Ming; Liu, Feiyan; Zhang, Chang; Liu, Xueqing; Liu, Jiyan; Zou, Liyong; Chen, Jia
2017-08-01
Flame-retardant polyvinyl alcohol (PVA) membranes with high transparency and flexibility were prepared by mixing an aqueous solution of a phosphorus-containing acrylic acid (AOPA) with PVA. The reaction between AOPA and PVA, the transparency, the crystallinity and the flexibility of the membrane were investigated with Fourier transform infrared spectrometry (FTIR), UV-vis light transmittance, X-ray diffraction and tensile tests, respectively. The limited oxygen index (LOI) and vertical flame (UL 94 VTM), microscale combustion calorimetry, thermogravimetric analysis (TGA) and TGA-FTIR were employed to evaluate the flame retardancy as well as to reveal the corresponding mechanisms. Results showed that PVA containing 30 wt% of AOPA can reach the UL 94 VTM V0 rating with an LOI of 27.3% and retain 95% of the original transparency of pure PVA. Adding AOPA reduces crystallinity of PVA, while the flexibility is increased. AOPA depresses the thermal degradation of PVA and promotes char formation during combustion. The proposed decomposition mechanism indicates that AOPA acts mainly in the condensed phase.
Production of anhydrous aluminum chloride composition
Vandergrift, G.F. III; Krumpelt, M.; Horwitz, E.P.
1981-10-08
A process is described for producing an anhydrous aluminum chloride composition from a water-based aluminous material such as a slurry of aluminum hydroxide in a multistage extraction process in which the aluminum ion is first extracted into an organic liquid containing an acidic extractant and then extracted from the organic phase into an alkali metal chloride or chlorides to form a melt containing a mixture of chlorides of alkali metal and aluminum. In the process, the organic liquid may be recycled. In addition, the process advantageously includes an electrolysis cell for producing metallic aluminum and the alkali metal chloride or chlorides may be recycled for extraction of the aluminum from the organic phase.
Production of anhydrous aluminum chloride composition and process for electrolysis thereof
Vandegrift, George F.; Krumpelt, Michael; Horwitz, E. Philip
1983-01-01
A process for producing an anhydrous aluminum chloride composition from a water-based aluminous material such as a slurry of aluminum hydroxide in a multistage extraction process in which the aluminum ion is first extracted into an organic liquid containing an acidic extractant and then extracted from the organic phase into an alkali metal chloride or chlorides to form a melt containing a mixture of chlorides of alkali metal and aluminum. In the process, the organic liquid may be recycled. In addition, the process advantageously includes an electrolysis cell for producing metallic aluminum and the alkali metal chloride or chlorides may be recycled for extraction of the aluminum from the organic phase.
[Decreasing the Output of Biomedical Waste in the Intensive Care Unit].
Shen, Ming-Yi; Chang, Chun-Chu; Li, Mung-Yeng; Lin, Jui-Hsiang
2017-10-01
Advancing healthcare technologies have increased the use of disposable supplies that are made with PVC (polyvinyl chloride). Furthermore, biomedical effluents are steadily increasing due to severe patient treatment requirements in intensive care units. If these biomedical wastes are not properly managed and disposed, they will cause great harm to the environment and to public health. The statistics from an intensive care unit at one medical center in northern Taiwan show that the per-person biomedical effluents produced in 2014 increased 8.51% over 2013 levels. The main reasons for this increase included the low accuracy of classification of the contents of biomedical effluent collection buckets and of personnel effluents in the intensive care unit and the generally poor selection and designation of appropriate containers. Improvement measures were implemented in order to decrease the per-day weight of biomedical effluents by 10% per person (-0.22 kg/person/day). The project team developed various strategies, including creating classification-related slogans and posting promotional posters, holding education and training using actual case studies, establishing an "environmental protection pioneer" team, and promoting the use of appropriate containers. The implementation of the project decreased the per-day weight of biomedical effluents by 13.2% per person. Implementation of the project effectively reduced the per-person daily output of biological wastes and improved the waste separation behavior of healthcare personnel in the unit, giving patients and their families a better healthcare environment and helping advance the cause of environmental protection worldwide.
Proteus mirabilis biofilm - qualitative and quantitative colorimetric methods-based evaluation.
Kwiecinska-Piróg, Joanna; Bogiel, Tomasz; Skowron, Krzysztof; Wieckowska, Ewa; Gospodarek, Eugenia
2014-01-01
Proteus mirabilis strains ability to form biofilm is a current topic of a number of research worldwide. In this study the biofilm formation of P. mirabilis strains derived from urine of the catheterized and non-catheterized patients has been investigated. A total number of 39 P. mirabilis strains isolated from the urine samples of the patients of dr Antoni Jurasz University Hospital No. 1 in Bydgoszcz clinics between 2011 and 2012 was used. Biofilm formation was evaluated using two independent quantitative and qualitative methods with TTC (2,3,5-triphenyl-tetrazolium chloride) and CV (crystal violet) application. The obtained results confirmed biofilm formation by all the examined strains, except quantitative method with TTC, in which 7.7% of the strains did not have this ability. It was shown that P. mirabilis rods have the ability to form biofilm on the surfaces of both biomaterials applied, polystyrene and polyvinyl chloride (Nelaton catheters). The differences in ability to form biofilm observed between P. mirabilis strains derived from the urine of the catheterized and non-catheterized patients were not statistically significant.
Hoechst and Wacker plan joint venture in PVC
DOE Office of Scientific and Technical Information (OSTI.GOV)
Young, I.
1992-12-02
Restructuring of Europe's petrochemical industry has taken a further step with the announcement that Hoechst (Frankfurt) and Wacker Chemie (Munich) are planning a joint venture in polyvinyl chloride (PVC). The venture would include production, R D, sales and marketing, plus both companies' PVC recycling activities. However, their vinyl chloride monomer (VCM) plants, and Hoechst's Kalle PVC film business, have been left out. Erich Schnitzler, head of Hoechst's PVC business unit, does not anticipate problems with the European Community's competition directorate. We are both among the middle-sized European PVC producers, and together we would have a 9%-10% market share. Our jointmore » venture would not limit competition. Both partners are hoping for approval from Brussels in first-quarter 1993. Hoechst has 255,000 m.t./year of PVC capacity at Gendorfand Knapsack, while Wacker has 365,000 m.t./year at Burghausen and Cologne. All the units, except Wacker's Cologne plant, are back integrated to VCM. The joint venture would buy VCM from the two parent companies and on the merchant market.« less
One step linear reconstruction method for continuous wave diffuse optical tomography
NASA Astrophysics Data System (ADS)
Ukhrowiyah, N.; Yasin, M.
2017-09-01
The method one step linear reconstruction method for continuous wave diffuse optical tomography is proposed and demonstrated for polyvinyl chloride based material and breast phantom. Approximation which used in this method is selecting regulation coefficient and evaluating the difference between two states that corresponding to the data acquired without and with a change in optical properties. This method is used to recovery of optical parameters from measured boundary data of light propagation in the object. The research is demonstrated by simulation and experimental data. Numerical object is used to produce simulation data. Chloride based material and breast phantom sample is used to produce experimental data. Comparisons of results between experiment and simulation data are conducted to validate the proposed method. The results of the reconstruction image which is produced by the one step linear reconstruction method show that the image reconstruction almost same as the original object. This approach provides a means of imaging that is sensitive to changes in optical properties, which may be particularly useful for functional imaging used continuous wave diffuse optical tomography of early diagnosis of breast cancer.
NASA Astrophysics Data System (ADS)
Bao, Lixia; Yang, Simei; Luo, Xin; Lei, Jingxin; Cao, Qiue; Wang, Jiliang
2015-12-01
The hydroxylated PVC (PVC-OH) was successfully synthesized by a suspension polymerization of vinyl chloride (VC), butyl acrylate (BA) and hydroxyethyl acrylate (HEA). Novel hydrophobic CaCO3 was then prepared by a urethane formation reaction between methylene diphenyl diisocyanate (MDI) and the sbnd OH groups both in the PVC-OH chains and on the surface of pristine CaCO3 particles. The effect of the PVC-OH content on the grafting ratio of treated CaCO3 particles was extensively investigated. Combining the result of Fourier transform infrared (FTIR) with that of water contact angle, it can be concluded that the hydrophobicity of CaCO3 had been efficiently improved by the PVC-OH segments grafted on the surface of CaCO3 particles. X-ray diffraction (XRD), thermal gravity analysis (TGA), scanning electron microscope (SEM) and transmission electron microscope (TEM) were also used to study crystalline behaviors, thermal stability and surface morphology of the modified CaCO3 particles, respectively. The change of specific surface area implying surface modification was investigated as well.
Diffusion of residual monomer in polymer resins.
Piver, W T
1976-01-01
A simplified mathematical model which made use of Fick's laws of diffusion written in spherical coordinates was developed to describe the rate of diffusion of residual monomers from polymer resins. The properties of the monomer-polymer system which influenced the amount of monomer remaining in the polymer as a function of time were the diffusivity and solubility of the monomer in the polymer, and the particle size of the polymer resin. This model was used to analyze literature data on the diffusion of residual vinyl chloride monomer in polyvinyl chloride resins made by the suspension process. It was concluded that particle size of the resin was a significant parameter which should be taken advantage of in process equipment designed to remove residual monomer from PVC resins. The diffusivity of the monomer in the polymer was a function of the solubility of the monomer in the polymer. Monomer solubility can be determined from Henry's law. It was suggested that this model could be adapted to describe diffusion of monomers from any monomer-polymer system, and would be a useful approach to modeling the transport of nonreactive chemical additives from plastics. PMID:1026410
Mundt, Kenneth A; Dell, Linda D; Crawford, Lori; Gallagher, Alexa E
2017-01-01
Objective To evaluate mortality risks of angiosarcoma of the liver (ASL), primary hepatocellular carcinoma (HCC) and other cancers among 9951 men employed between 1942 and 1972 at 35 US vinyl chloride (VC) or polyvinyl chloride plants followed for mortality through 31 December 2013. Methods SMR and time-dependent Cox proportional hazards analyses were used to evaluate mortality risks by cumulative VC exposure. Results Liver cancer mortality was elevated (SMR=2.87, 95% CI 2.40 to 3.40), and ASL and HCC were strongly associated with cumulative VC exposure ≥865 parts per million-years (ppm-years) (ASL: HR=36.3, 95% CI 13.1 to 100.5; and HCC: HR=5.3, 95% CI 1.6 to 17.7 for ≥2271 ppm-years). Excess deaths due to connective and soft tissue cancers (SMR=2.43, 95% CI 1.48 to 3.75), mesothelioma (SMR=2.29, 95% CI 1.18 to 4.00) and explosions (SMR=3.43, 95% CI 1.25 to 7.47) were seen. Mortalities due to melanoma, brain cancer, lung cancer and non-Hodgkin’s lymphoma were not increased or associated with VC exposure. Conclusion The association between VC and ASL first reported in this cohort 44 years ago persisted and was strongest among workers most highly exposed. VC exposure also was associated with HCC mortality, although it remains possible that misdiagnosis of early ASLs influenced findings. PMID:28490663
Abdelkader, D H; Osman, M A; El-Gizawy, S A; Faheem, A M; McCarron, P A
2016-03-16
Poly(vinyl alcohol) hydrogels cross-linked with the tetrahydroxyborate anion possess textural and rheological properties that can be used as novel drug-loaded vehicles for application to traumatic wounds. However, addition of soluble drug substances causes concentration-dependent phase separation and rheological changes. The aim of this work was to investigate the effect of adding a local anaesthetic, but keeping the concentration low in an attempt to prevent these changes. Cross-linked hydrogels prepared from three grades of poly(vinyl alcohol) were characterised rheologically. Temperature sweep studies showed an elevated complex viscosity upon moving from 25°C to 80°C, which remained high for 48 h following completion of the cycle. Adhesion to model dermal surfaces achieved a maximum of 2.62 N cm(-2) and were greater than that observed to epidermal substrates, with a strong dependence on the rate of detachment used during testing. An optimised formulation (6% w/w PVA (31-50; 99) and 2% w/w THB) containing lidocaine hydrochloride loaded to an upper maximum concentration of 1.5% w/w was assessed for phase separation and drug crystallisation. After six months, crystallisation was present in formulations containing 0.7% and 1.5% lidocaine HCl. Changes in pH in response to increases in lidocaine loading were low. Drug release was shown to operate via a non-Fickian process for all three concentrations, with 60% occurring after approximately 24h. It can be concluded that using a low concentration of lidocaine hydrochloride in hydrogels based on poly(vinyl alcohol) will result in crystallisation. Furthermore, these hydrogels are unlikely to induce rapid anaesthesia due to the low loading and slow release kinetics. Copyright © 2016 Elsevier B.V. All rights reserved.
Pyrolysis of poly(vinyl chloride) and-electric arc furnacedust mixtures.
Al-Harahsheh, Mohammad; Al-Otoom, Awni; Al-Makhadmah, Leema; Hamilton, Ian E; Kingman, Sam; Al-Asheh, Sameer; Hararah, Muhanned
2015-12-15
An investigation into the pyrolysis kinetics of PVC mixed with electric arc furnace dust (EAFD) was performed. Mixtures of both materials with varying PVC ratios (1:1, 1:2, 1:3) were prepared and pyrolyzed in a nitrogen atmosphere under dynamic heating conditions at different heating rates (5, 10, 30 and 50 °C/min). The pyrolysis process proceeded through two main decomposition steps; the first step involved the release of HCl which reacted with the metal oxides present in the dust, subsequently forming metal chlorides and water vapor. Benzene was also found to release as detected by TGA-MS. The remaining hydrocarbons in the polymer backbone decomposed further in the second step releasing further volatile hydrocarbons. Different models were used to fit the kinetic data namely the integral, the Van Krevelen, and Coats and Red fern methods. The presence of EAFD during PVC decomposition resulted in a considerable decrease in the activation energy of the reaction occurring during the first decomposition region. Furthermore, iron oxides were retained in the pyrolysis residue, whilst other valuable metals, including Zn and Pb, were converted to chlorides that are recoverable by leaching in water. It is believed that EAFD can be utilized as an active catalyst to produce energy gases such as propyneas evident from the TGA-MS. Copyright © 2015 Elsevier B.V. All rights reserved.
Peng, Tzu-Huan; Lin, Chiou-Liang; Wey, Ming-Yen
2015-09-15
A novel low-temperature two-stage fluidized bed (LTTSFB) incinerator has been successfully developed to control heavy-metal emissions during municipal solid waste (MSW) treatment. However, the characteristics of the residual metal patterns during this process are still unclear. The aim of this study was to investigate the metal patterns in the different partitions of the LTTSFB bottom ash by chemical sequential extraction. Artificial waste was used to simulate the MSW. Different parameters including the first-stage temperature, chloride additives, and operating gas velocity were also considered. Results indicated that during the low-temperature treatment process, a high metal mobility phase exists in the first-stage sand bed. The main patterns of Cd, Pb, and Cr observed were the water-soluble, exchangeable, and residual forms, respectively. With the different Cl additives, the results showed that polyvinyl chloride addition increased metal mobility in the LTTSFB bottom ash, while, sodium chloride addition may have reduced metal mobility due to the formation of eutectic material. The second-stage sand bed was found to have a lower risk of metal leaching. The results also suggested that, the residual ashes produced by the LTTSFB system must be taken into consideration given their high metal mobility. Copyright © 2015 Elsevier B.V. All rights reserved.
Berrang, Mark E; Hofacre, Charles L; Frank, Joseph F
2014-12-01
Listeria monocytogenes can colonize a poultry processing plant as a resident in floor drains. Limiting growth and attachment to drain surfaces may help lessen the potential for cross-contamination of product. The objective of this study was to compare a hydrogen peroxide-peroxyacetic acid-based chemical to chitosan-arginine or heat to prevent attachment of or destroy existing L. monocytogenes on the inner surface of model floor drains. L. monocytogenes was introduced to result in about 10(9) planktonic and attached cells within untreated polyvinyl chloride model drain pipes. Treatments (0.13 % peroxide-based sanitizer, 0.1 % chitosan-arginine, or 15 s of hot water at 95 to 100°C) were applied immediately after inoculation or after 24 h of incubation. Following treatment, all pipes were incubated for an additional 24 h; planktonic and attached cells were enumerated by plate count. All treatments significantly (P < 0.05) lowered numbers of planktonic and attached cells recovered. Chitosan-arginine resulted in approximately a 6-log reduction in planktonic cells when applied prior to incubation and a 3-log reduction after the inoculum had a chance to grow. Both heat and peroxide significantly outperformed chitosan-arginine (8- to 9-log reduction) and were equally effective before and after incubation. Heat was the only treatment that eliminated planktonic L. monocytogenes. All treatments were less effective against attached cells. Chitosan-arginine provided about a 4.5-log decrease in attached cells when applied before incubation and no significant decrease when applied after growth. Like with planktonic cells, peroxide-peroxyacetic acid and heat were equally effective before or after incubation, causing decreases ranging from 7 to 8.5 log for attached L. monocytogenes. Applied at the most efficacious time, any of these techniques may lessen the potential for L. monocytogenes to remain as a long-term resident in processing plant floor drains.
Ferrocene bound poly(vinyl chloride) as ion to electron transducer in electrochemical ion sensors.
Pawlak, Marcin; Grygolowicz-Pawlak, Ewa; Bakker, Eric
2010-08-15
We report here on the synthesis of poly(vinyl chloride) (PVC) covalently modified with ferrocene groups (FcPVC) and the electrochemical behavior of the resulting polymeric membranes in view of designing all solid state voltammetric ion sensors. The Huisgen cycloaddition ("click chemistry") was found to be a simple and efficient method for ferrocene attachment. A degree of PVC modification with ferrocene groups between 1.9 and 6.1 mol % was achieved. The chemical modification of the PVC backbone does not significantly affect the ion-selective properties (selectivity, mobility, and solvent casting ability) of potentiometric sensing membranes applying this polymer. Importantly, the presence of such ferrocene groups may eliminate the need for an additional redox-active layer between the membrane and the inner electric contact in all solid state sensor designs. Electrochemical doping of this system was studied in a symmetrical sandwich configuration: glassy carbon electrode |FcPVC| glassy carbon electrode. Prior electrochemical doping from aqueous solution, resulting in a partial oxidation of the ferrocene groups, was confirmed to be necessary for the sandwich configuration to pass current effectively. The results suggest that only approximately 2.3 mol % of the ferrocene groups are electrochemically accessible, likely due to surface confined electrochemical behavior in the polymer. Indeed, cyclic voltammetry of aqueous hexacyanoferrate (III) remains featureless at cathodic potentials (down to -0.5 V). This indicates that the modified membrane is not responsive to redox-active species in the sample solution, making it possible to apply this polymer as a traditional, single membrane. Yet, the redox capacity of the electrode modified with this type of membrane was more than 520 microC considering a 20 mm(2) active electrode area, which appears to be sufficient for numerous practical ion voltammetric applications. The electrode was observed to operate reproducibly, with 1% standard deviation, when applying pulsed amperometric techniques.
42 CFR 84.250 - Vinyl chloride respirators; description.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 42 Public Health 1 2010-10-01 2010-10-01 false Vinyl chloride respirators; description. 84.250... Respirators § 84.250 Vinyl chloride respirators; description. Vinyl chloride respirators, including all... escape from vinyl chloride atmospheres containing adequate oxygen to support life, are described...
NASA Astrophysics Data System (ADS)
Shah, Bhavesh
This dissertation focuses on overcoming existing limitations of WPCs which prevent them from realizing their full market potential. These limitations include: (i) lack of a continuous extrusion process for microcellular foaming of polyvinyl chloride (PVC) and its composites using supercritical fluids to reduce the high density of the WPCs, (ii) need for an efficient coupling agent for WPCs to overcome the poor compatibility between wood and plastic, and (iii) unproven use of wood as a filler for the biopolymer polylactide (PLA) to make "green" composites. These limitations were addressed through experimentation to develop a continuous extrusion process for microcellular foaming, and through surface modification of wood flour using natural coupling agents. The effects of wood flour, acrylic modifier and plasticizer content on the rheological properties of PVC based WPCs were studied using an extrusion capillary rheometer and a two-level factorial design. Wood flour content and acrylic modifier content were the major factors affecting the die swell ratio. Addition of plasticizer decreased the true viscosity of unfilled and filled PVC, irrespective of the acrylic modifier content. However, the addition of acrylic modifier significantly increased the viscosity of unfilled PVC but decreased the composite viscosity. Results of the rheological study were used to set baseline conditions for the continuous extrusion foaming of PVC WPCs using supercritical CO 2. Effects of material composition and processing conditions on the morphology of foamed samples were investigated. Foamed samples were produced using various material compositions and processing conditions, but steady-state conditions could not be obtained for PVC. Thus the relationships could not be determined. Incompatibility between wood flour and PVC was the focus of another study. The natural polymers chitin and chitosan were used as novel coupling agents to improve interfacial adhesion between the polymer matrix and wood fiber. Results indicated that addition of chitin and chitosan significantly increased the flexural properties and storage modulus of PVC WPCs, compared to composites without coupling agent. Significant improvements were attained with 0.5 wt. % chitosan and with 6.67 wt. % chitin. Based on the efficiency of chitosan as a coupling agent for PVC based WPCs, a biodegradable composite using polylactide (PLA) and chitosan was developed. Wood flour (0--40 wt. %) was evaluated as a filler for PLA composites and its effect on mechanical, thermal and chemical properties was studied with and without chitosan (0--10 wt. %). Addition of wood flour significantly increased the flexural and storage moduli of PLA-wood flour composites, but had no effect on glass transition temperature (Tg). Chitosan had no significant effect on any of the properties of the composites studied. Development of an efficient and effective coupling agent for PVC wood composite is a significant development which will increase performance while reducing cost. Wood filled PLA composites can further expand WPCs into applications such as packaging and automotive. Results from these studies have broadened the current knowledge base for WPC products and will be useful in the continued expansion of wood composites technology into a variety of industries.
Wang, Hai-Yan; Lu, Shu-Shen; Lun, Zhao-Rong
2009-02-01
Knowledge of the glass transition behavior of vitrification solutions is important for research and planning of the cryopreservation of biological materials by vitrification. This brief communication shows the analysis for the glass transition and glass stability of the multi-component vitrification solutions containing propanediol (PE), dimethyl sulfoxide (Me2SO) and polyvinyl alcohol (PVA) by using differential scanning calorimetry (DSC) during the cooling and subsequent warming between 25 and -150 degrees C. The glass formation of the solutions was enhanced by introduction of PVA. Partial glass formed during cooling and the fractions of free water in the partial glass matrix increased with the increasing of PVA concentration, which caused slight decline of glass transition temperature, T(g). Exothermic peaks of devitrification were delayed and broadened, which may result from the inhibition of ice nucleation or recrystallization of PVA.
PVC-based composite material containing recycled non-metallic printed circuit board (PCB) powders.
Wang, Xinjie; Guo, Yuwen; Liu, Jingyang; Qiao, Qi; Liang, Jijun
2010-12-01
The study is directed to the use of non-metallic powders obtained from comminuted recycled paper-based printed circuit boards (PCBs) as an additive to polyvinyl chloride (PVC) substrate. The physical properties of the non-metallic PCB (NMPCB) powders were measured, and the morphological, mechanical and thermal properties of the NMPCB/PVC composite material were investigated. The results show that recycled NMPCB powders, when added below a threshold, tended to increase the tensile strength and bending strength of PVC. When 20 wt% NMPCB powders (relative to the substrate PVC) of an average diameter of 0.08 mm were added, the composite tensile strength and bending strength reached 22.6 MPa and 39.83 MPa, respectively, representing 107.2% and 123.1% improvement over pure PVC. The elongation at break of the composite material reached 151.94% of that of pure PVC, while the Vicat softening temperature of the composite material did not increase significantly compared to the pure PVC. The above results suggest that paper-based NMPCB powders, when used at appropriate amounts, can be effective for toughening PVC. Thus, this study suggests a new route for reusing paper-based NMPCB, which may have a significant beneficial environmental impact. Copyright © 2010 Elsevier Ltd. All rights reserved.
Masadome, Takashi; Miyanishi, Takaaki; Watanabe, Keita; Ueda, Hiroshi; Hattori, Toshiaki
2011-01-01
A solution of polyhexamethylene biguanide hydrochloride (PHMB-HCl) was titrated with a standard solution of potassium poly(vinyl sulfate) (PVSK) using crystal violet (CV) as an photometric indicator cation. The end point was detected by a sharp absorbance change due to an abrupt decrease in the concentration of CV. A linear relationship between the concentration of PHMB-HCl and the end-point volume of the titrant existed in the concentration range from 2 to 10 × 10(-6) eq mol L(-1). Back-titration was based on adding an excess amount of PVSK to a sample solution containing CV, which was titrated with a standard solution of poly(diallyldimethylammonium chloride) (PDADMAC). The calibration curve of the PHMB-HCl concentration to the end point volume of the titrant was also linear in the concentration range from 2 to 8 × 10(-6) eq mol L(-1). Both photometric titrations were applied to the determination of PHMB-HCl in a few contact-lens detergents. Back-titration showed a clear end point, but direct titration showed an unclear end point. The results of the back-titration of PHMB-HCl were compared with the content registered in its labels. 2011 © The Japan Society for Analytical Chemistry
NASA Astrophysics Data System (ADS)
Dinesh, Meghala; Chikkakuntappa, Ranganathaiah
2013-09-01
Ternary polymer blends of poly(styrene-co-acrylonitrile)/poly(ethylene-co-vinylacetate)/poly(vinyl chloride) (SAN/EVA/PVC) and poly(vinyl acetate)/bisphenol A/polyvinylpyrrolidone (PVAc/BPA/PVP) with different compositions have been prepared by solvent casting method and characterized by positron lifetime spectroscopy and differential scanning calorimetry DSC. Phase modifications have been induced by irradiating the blends with microwave radiation. These changes have been monitored by measuring the free-volume content in the blends. The results clearly show improved interactions between the constituent polymers of the blends upon microwave irradiation. However, the free-volume data and DSC measurements are found to be inadequate to reveal the changes at the interfaces and the interfaces determine the final properties of the blend. For this we have used hydrodynamic interaction (αij) approach developed by us to measure strength of hydrodynamic interaction at the interfaces. These results show that microwave irradiation stabilizes the interfaces if the blend contains strong polar groups. SAN/EVA/PVC blend shows an increased effective hydrodynamic interaction from -3.18 to -4.85 at composition 50/35/15 upon microwave irradiation and PVAc/BPA/PVP blend shows an increased effective hydrodynamic interaction from -3.81 to -7.57 at composition 20/50/30 after irradiation.
Comparison of bacterial attachment to platelet bags with and without preconditioning with plasma.
Loza-Correa, M; Kalab, M; Yi, Q-L; Eltringham-Smith, L J; Sheffield, W P; Ramirez-Arcos, S
2017-07-01
Canadian Blood Services produces apheresis and buffy coat pooled platelet concentrates (PCs) stored in bags produced by two different manufacturers (A and B, respectively), both made of polyvinyl chloride-butyryl trihexyl citrate. This study was aimed at comparing Staphylococcus epidermidis adhesion to the inner surface of both bag types in the presence or absence of plasma factors. Sets (N = 2-6) of bags type A and B were left non-coated (control) or preconditioned with platelet-rich, platelet-poor or defibrinated plasma (PRP, PPP and DefibPPP, respectively). Each bag was inoculated with a 200-ml S. epidermidis culture adjusted to 0·5 colony-forming units/ml. Bags were incubated under platelet storage conditions for 7 days. After culture removal, bacteria attached to the plastic surface were either dislodged by sonication for bacterial quantification or examined in situ by scanning electron microscopy (SEM). Higher bacterial adhesion was observed to preconditioned PC bags than control containers for both bag types (P < 0·0001). Bacterial attachment to preconditioned bags was confirmed by SEM. Bacteria adhered equally to both types of containers in the presence of PRP, PPP and DefibPPP residues (P > 0·05). By contrast, a significant increase in bacterial adherence was observed to type A bags compared with type B bags in the absence of plasma (P < 0·05) [Correction added on 16 June 2017, after first online publication: this sentence has been corrected]. The ability of S. epidermidis to adhere to preconditioned platelet collection bags depends on the presence of plasma factors. Future efforts should be focused on reducing plasma proteins' attachment to platelet storage containers to decrease subsequent bacterial adhesion. © 2017 International Society of Blood Transfusion.
Mallampati, Srinivasa Reddy; Lee, Byoung Ho; Mitoma, Yoshiharu; Simion, Cristian
2017-02-01
One method of weakening the inherently hydrophobic surface of plastics relevant to flotation separation is heterogeneous nano-Fe/Ca/CaO catalytic ozonation. Nano-Fe/Ca/CaO-catalyzed ozonation for 15 min efficiently decreases the surface hydrophobicity of brominated and chlorinated flame retardant (B/CFR)-containing plastics (such as acrylonitrile-butadienestyrene (ABS), high-impact polystyrene (HIPS), and polyvinyl chloride (PVC)) in automobile shredder residue (ASR) to such an extent that their flotation ability is entirely depressed. Such a hydrophilization treatment also stimulates the ABS, HIPS, and PVC surface roughness, wetting of the surface, and the thermodynamic equilibrium conditions at the surface and ultimately changes surface polarity. SEM-EDS, AFM, and XPS analyses of the PVC and ABS surfaces demonstrated a marked decrease in [Cl/Br] and a significant increase in the number of hydrophilic groups, such as C-O, C=O, and (C=O)-O. Under froth flotation conditions at 50 rpm, about 99.5 % of ABS and 99.5 % of HIPS in ASR samples settled out, resulting in a purity of 98 and 98.5 % for ABS and HIPS in ASR samples, respectively. Furthermore, at 150 rpm, we also obtained 100 % PVC separation in the settled fraction, with 98 % purity in ASR. Total recovery of non-B/CFR-containing plastics reached nearly 100 % in the floating fraction. The amount of nano-Fe/Ca/CaO reagent employed during ozonation is very small, and additional removal of surface contaminants from the recycled ASR plastic surfaces by ozonation makes the developed process simpler, greener, and more effective.
21 CFR 522.1862 - Sterile pralidoxime chloride.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Sterile pralidoxime chloride. 522.1862 Section 522....1862 Sterile pralidoxime chloride. (a) Chemical name. 2-Formyl-1-methylpyridinium chloride oxime. (b) Specifications. Sterile pralidoxime chloride is packaged in vials. Each vial contains 1 gram of sterile...
Lindemann, J; Leiacker, R; Wiesmiller, K; Rettinger, G; Keck, T
2004-08-01
Benzalkonium chloride is a preservative commonly used in nasal decongestant sprays. It has been suggested that benzalkonium chloride may be harmful to the nasal mucosa. Decongestion with the vasoconstrictor xylometazoline containing benzalkonium chloride has been shown to cause a significant reduction of the nasal mucosal temperature. The purpose of the present study was to determine the short-term influence of xylometazoline nasal spray with and without benzalkonium chloride on the nasal mucosal temperature. Healthy volunteers (30) were included in the study. Fifteen volunteers received xylometazoline nasal spray (1.0 mg/mL) containing benzalkonium chloride (0.1 mg/mL) and 15 age-matched subjects, received xylometazoline nasal spray without benzalkonium chloride. Using a miniaturized thermocouple the septal mucosal temperature was continuously measured at defined intranasal detection sites before and after application of the nasal spray. The mucosal temperature values did not significantly differ between the group receiving xylometazoline containing benzalkonium chloride and the group receiving xylometazoline spray without benzalkonium chloride before and after decongestion (P > 0.05). In both study groups septal mucosal temperatures significantly decreased after decongestion (P < 0.05) because of a reduction of the nasal mucosal blood flow following vasoconstriction. This study indicates that benzalkonium chloride itself does not seem to influence nasal blood flow and nasal mucosal temperature in topical nasal decongestants.
Microstickies agglomeration by electric field.
Du, Xiaotang Tony; Hsieh, Jeffery S
2016-01-01
Microstickies deposits on both paper machine and paper products when it agglomerates under step change in ionic strength, pH, temperature and chemical additives. These stickies increase the down time of the paper mill and decrease the quality of paper. The key property of microstickies is its smaller size, which leads to low removal efficiency and difficulties in measurement. Thus the increase of microstickies size help improve both removal efficiency and reduce measurement difficulty. In this paper, a new agglomeration technology based on electric field was investigated. The electric treatment could also increase the size of stickies particles by around 100 times. The synergetic effect between electric field treatment and detacky chemicals/dispersants, including polyvinyl alcohol, poly(diallylmethylammonium chloride) and lignosulfonate, was also studied.
A new infusion pathway monitoring system utilizing electrostatic induced potential.
Maki, Hiromichi; Yonezawa, Yoshiharu; Ogawa, Hidekuni; Ninomiya, Ishio; Sada, Kouji; Hamada, Shingo; Hahn, Alien W; Caldwell, W Morton
2006-01-01
We have developed a new infusion pathway monitoring system employing linear integrated circuits and a low-power 8-bit single chip microcomputer. The system is available for hospital and home use and it constantly monitors the intactness of the pathway. The sensor is an electro-conductive polymer electrode wrapped around the infusion polyvinyl chloride infusion tube. This records an AC (alternating current) voltage induced on the patient's body by electrostatic coupling from the normal 100 volt, 60 Hz AC power line wiring field in the patient's room. If the injection needle or infusion tube becomes detached, then the system detects changes in the induced AC voltage and alerts the nursing station, via the nurse call system or PHS (personal handy phone System).
Auger analysis of films formed on metals in sliding contact with halogenated polymers
NASA Technical Reports Server (NTRS)
Pepper, S. V.
1974-01-01
The use of Auger electron spectroscopy (AES) to search for transferred polymer must contend with the fact that there has been no published work on Auger analysis of polymers. Since this is a new area for AES, the Auger spectra of polymers and of halogenated polymers in particular is discussed. It is shown that the Auger spectra of halogenated polymers have certain characteristics that permit an assessment of whether a polymeric transfer film has been established by sliding contact. The discussion is general and the concepts should be useful in considering the Auger analysis of any polymer. The polymers chosen for this study are the halogenated polymers polytetrafluoroethylene (PTFE), polyvinyl chloride (PVC), and polychlorotrifluorethylene (PCTFE).
Experiments on elastic cloaking in thin plates.
Stenger, Nicolas; Wilhelm, Manfred; Wegener, Martin
2012-01-06
Following a theoretical proposal [M. Farhat et al., Phys. Rev. Lett. 103, 024301 (2009)], we design, fabricate, and characterize a cloaking structure for elastic waves in 1 mm thin structured polymer plates. The cloak consists of 20 concentric rings of 16 different metamaterials, each being a tailored composite of polyvinyl chloride and polydimethylsiloxane. By using stroboscopic imaging with a camera from the direction normal to the plate, we record movies of the elastic waves for monochromatic plane-wave excitation. We observe good cloaking behavior for carrier frequencies in the range from 200 to 400 Hz (one octave), in good agreement with a complete continuum-mechanics numerical treatment. This system is thus ideally suited for demonstration experiments conveying the ideas of transformation optics.
Lewis, Michele A.; Johnson, Terry R.
1993-01-01
The invention is a method for the encapsulation of soluble radioactive waste chloride salts containing radionuclides such as strontium, cesium and hazardous wastes such as barium so that they may be permanently stored without future threat to the environment. The process consists of contacting the salts containing the radionuclides and hazardous wastes with certain zeolites which have been found to ion exchange with the radionuclides and to occlude the chloride salts so that the resulting product is leach resistant.
Lewis, Michele A.; Johnson, Terry R.
1993-09-07
The invention is a method for the encapsulation of soluble radioactive waste chloride salts containing radionuclides such as strontium, cesium and hazardous wastes such as barium so that they may be permanently stored without future threat to the environment. The process consists of contacting the salts containing the radionuclides and hazardous wastes with certain zeolites which have been found to ion exchange with the radionuclides and to occlude the chloride salts so that the resulting product is leach resistant.
Method for synthesizing pollucite from chabazite and cesium chloride
Pereira, C.
1999-02-23
A method is described for immobilizing waste chlorides salts containing radionuclides and hazardous nuclear material for permanent disposal, and in particular, a method is described for immobilizing waste chloride salts containing cesium, in a synthetic form of pollucite. The method for synthesizing pollucite from chabazite and cesium chloride includes mixing dry, non-aqueous cesium chloride with chabazite and heating the mixture to a temperature greater than the melting temperature of the cesium chloride, or above about 700 C. The method further comprises significantly improving the rate of retention of cesium in ceramic products comprised of a salt-loaded zeolite by adding about 10% chabazite by weight to the salt-loaded zeolite prior to conversion at elevated temperatures and pressures to the ceramic composite. 3 figs.
Method for synthesizing pollucite from chabazite and cesium chloride
Pereira, Candido
1999-01-01
A method for immobilizing waste chlorides salts containing radionuclides and hazardous nuclear material for permanent disposal, and in particular, a method for immobilizing waste chloride salts containing cesium, in a synthetic form of pollucite. The method for synthesizing pollucite from chabazite and cesium chloride includes mixing dry, non-aqueous cesium chloride with chabazite and heating the mixture to a temperature greater than the melting temperature of the cesium chloride, or above about 700.degree. C. The method further comprises significantly improving the rate of retention of cesium in ceramic products comprised of a salt-loaded zeolite by adding about 10% chabazite by weight to the salt-loaded zeolite prior to conversion at elevated temperatures and pressures to the ceramic composite.
Solid state NMR and LVSEM studies on the hardening of latex modified tile mortar systems
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rottstegge, J.; Arnold, M.; Herschke, L.
Construction mortars contain a broad variety of both inorganic and organic additives beside the cement powder. Here we present a study of tile mortar systems based on portland cement, quartz, methyl cellulose and different latex additives. As known, the methyl cellulose stabilizes the freshly prepared cement paste, the latex additive enhances final hydrophobicity, flexibility and adhesion. Measurements were performed by solid state nuclear magnetic resonance (NMR) and low voltage scanning electron microscopy (LVSEM) to probe the influence of the latex additives on the hydration, hardening and the final tile mortar properties. While solid state NMR enables monitoring of the bulkmore » composition, scanning electron microscopy affords visualization of particles and textures with respect to their shape and the distribution of the different phases. Within the alkaline cement paste, the poly(vinyl acetate) (VAc)-based latex dispersions stabilized by poly(vinyl alcohol) (PVA) were found to be relatively stable against hydrolysis. The influence of the combined organic additives methyl cellulose, poly(vinyl alcohol) and latexes stabilized by poly(vinyl alcohol) on the final silicate structure of the cement hydration products is small. But even small amounts of additives result in an increased ratio of ettringite to monosulfate within the final hydrated tile mortar as monitored by {sup 27}Al NMR. The latex was found to be adsorbed to the inorganic surfaces, acting as glue to the inorganic components. For similar latex water interfaces built up by poly(vinyl alcohol), a variation in the latex polymer composition results in modified organic textures. In addition to the networks of the inorganic cement and of the latex, there is a weak network build up by thin polymer fibers, most probably originating from poly(vinyl alcohol). Besides the weak network, polymer fibers form well-ordered textures covering inorganic crystals such as portlandite.« less
Peng, Sha; Zhou, Ming; Liu, Feiyan; Zhang, Chang; Liu, Xueqing; Liu, Jiyan; Zou, Liyong; Chen, Jia
2017-08-01
Flame-retardant polyvinyl alcohol (PVA) membranes with high transparency and flexibility were prepared by mixing an aqueous solution of a phosphorus-containing acrylic acid (AOPA) with PVA. The reaction between AOPA and PVA, the transparency, the crystallinity and the flexibility of the membrane were investigated with Fourier transform infrared spectrometry (FTIR), UV-vis light transmittance, X-ray diffraction and tensile tests, respectively. The limited oxygen index (LOI) and vertical flame (UL 94 VTM), microscale combustion calorimetry, thermogravimetric analysis (TGA) and TGA-FTIR were employed to evaluate the flame retardancy as well as to reveal the corresponding mechanisms. Results showed that PVA containing 30 wt% of AOPA can reach the UL 94 VTM V0 rating with an LOI of 27.3% and retain 95% of the original transparency of pure PVA. Adding AOPA reduces crystallinity of PVA, while the flexibility is increased. AOPA depresses the thermal degradation of PVA and promotes char formation during combustion. The proposed decomposition mechanism indicates that AOPA acts mainly in the condensed phase.
Ikeuchi-Takahashi, Yuri; Ishihara, Chizuko; Onishi, Hiraku
2017-09-01
The purpose of the present work was to evaluate polyvinyl alcohols (PVAs) as a mucoadhesive polymer for mucoadhesive buccal tablets prepared by direct compression. Various polymerization degree and particle diameter PVAs were investigated for their usability. The tensile strength, in vitro adhesive force, and water absorption properties of the tablets were determined to compare the various PVAs. The highest values of the tensile strength and the in vitro adhesive force were observed for PVAs with a medium viscosity and small particle size. The optimal PVA was identified by a factorial design analysis. Mucoadhesive tablets containing the optimal PVA were compared with carboxyvinyl polymer and hydroxypropyl cellulose formulations. The optimal PVA gives a high adhesive force, has a low viscosity, and resulted in relatively rapid drug release. Formulations containing carboxyvinyl polymer had high tensile strengths but short disintegration times. Higher hydroxypropyl cellulose concentration formulations had good adhesion forces and very long disintegration times. We identified the optimal characteristics of PVA, and the usefulness of mucoadhesive buccal tablets containing this PVA was suggested from their formulation properties.
USDA-ARS?s Scientific Manuscript database
Use of glycerin and calcium chloride to reduce the freezing point and improve quality of bulk stored fermented cucumbers brined without NaCl, was explored. The incidence of pre-freezing injury on the fruits, caused by deposition in tanks containing cushion brine prepared with 2.5% calcium chloride, ...
Desmaris, Romain-Pacôme; Mercier, Lionel; Paci, Angelo
2015-09-01
Melphalan is an alkylating agent frequently used in an intravenous formulation to treat hematologic malignancies and solid tumors in both adults and children. According to the manufacturer, melphalan is stable in sterile 0.9% sodium chloride for 90 min at room temperature (RT). Several authors have studied the stability of different concentrations of melphalan; however, most were not adapted to the current manufacturing process applied in pharmaceutical centralized units. This study was conducted to determine the stability of melphalan in 0.9% sodium chloride solutions at concentrations used for intravenous injection in practice. Melphalan is commonly prepared in diluted solutions ranging from 2 to 4 mg/ml for the treatment of adult patients and at lower concentrations (down to 0.5 mg/ml) for pediatric use. Accordingly, these were the three concentrations chosen for this study. Melphalan concentrations were measured with high-performance thin-layer chromatography (HPTLC). At RT, admixtures prepared at 4 mg/ml were stable for up to 8 h without protection from light; however, at lower concentrations, such as 0.5 and 2 mg/ml, stability did not exceed 2 h. When refrigerated, melphalan was stable for 24 h at 2 mg/ml; however, at 0.5 and 4 mg/ml, the drug was not stable. Melphalan solutions present with limited stability at 0.5, 2, and 4 mg/ml and are not adapted for delayed administration in pharmaceutical centralized units. However, at 4 mg/ml and at RT, a stability of 8 h is very interesting in practice and allows sufficient time for preparation, pharmaceutical control, transport, and administration.
NASA Astrophysics Data System (ADS)
Ovchinnikov, I. I.; Snezhkina, O. V.; Ovchinnikov, I. G.
2017-11-01
The task of modeling the kinetics of chloride-containing medium penetration into construction elements out of reinforced concrete that have partially damaged anti-corrosion protective coatings is being discussed. As a result, chlorides penetrate the construction element via local surface areas which leads to irregularities between chloride dispersion volumes. The kinetics of chloride penetration is described by the equation of diffusion to solve which the CONDUCT software complex by professor S. Patankar was used. The methodology used to solve the diffusional equation is described. The results of the evaluation of concentration field in the axial section of a cylindrical construction element, which was centrally reinforced, are given. The chloride diffusion was symmetrical to the axis, the medium was applied through the central ring area equal to one third of the side surface area while the rest of the surface was isolated. It was shown that the methodology of evaluation and its algorithm allow one to evaluate the concentration field of chlorides in reinforced concrete structural elements under local or asymmetrical action of the chloride - containing medium. The example given illustrates that after a certain time interval critical the concentration of chlorides develops even in protected areas which are located far from the initial damaged area. This means that the corrosion destruction of reinforced elements develops not only in the immediate damage area, but also further away from it.
EFFECTS OF CHRONIC EXCESS SALT FEEDING
Dahl, Lewis K.; Heine, Martha
1961-01-01
Female rats were fed diets containing either excess sea salt or excess sodium chloride for periods up to 14 months. The hypertension produced by sea salt was more pronounced than that caused by sodium chloride alone, although the average amount of sodium chloride contained in the sea salt feeding was slightly less. The ions involved in this incremental effect of sea salt were not identified. PMID:13719314
A METHOD OF PREPARING URANIUM DIOXIDE
Scott, F.A.; Mudge, L.K.
1963-12-17
A process of purifying raw, in particular plutonium- and fission- products-containing, uranium dioxide is described. The uranium dioxide is dissolved in a molten chloride mixture containing potassium chloride plus sodium, lithium, magnesium, or lead chloride under anhydrous conditions; an electric current and a chlorinating gas are passed through the mixture whereby pure uranium dioxide is deposited on and at the same time partially redissolved from the cathode. (AEC)
[Sodium chloride 0.9%: nephrotoxic crystalloid?].
Dombre, Vincent; De Seigneux, Sophie; Schiffer, Eduardo
2016-02-03
Sodium chloride 0.9%, often incorrectly called physiological saline, contains higher concentration of chloride compared to plasma. It is known that the administration of sodium chloride 0.9% can cause hyperchloremic metabolic acidosis in a reproducible manner. The elevated chloride concentration in 0.9% NaCl solution can also adversely affect renal perfusion. This effect is thought to be induced by hyperchloremia that causes renal artery vasoconstriction. For these reasons, the use of 0.9% NaCl solution is raising attention and some would advocate the use of a more "physiological" solution, such as balanced solutions that contain a level of chloride closer to that of plasma. Few prospective, randomized, controlled trials are available today and most were done in a perioperative setting. Some studies suggest that the chloride excess in 0.9% NaCl solution could have clinical consequences; however, this remains to be established by quality randomized controlled trials.
Buried chloride stereochemistry in the Protein Data Bank
2014-01-01
Background Despite the chloride anion is involved in fundamental biological processes, its interactions with proteins are little known. In particular, we lack a systematic survey of its coordination spheres. Results The analysis of a non-redundant set (pairwise sequence identity?30%) of 1739 high resolution (<2 Å) crystal structures that contain at least one chloride anion shows that the first coordination spheres of the chlorides are essentially constituted by hydrogen bond donors. Amongst the side-chains positively charged, arginine interacts with chlorides much more frequently than lysine. Although the most common coordination number is 4, the coordination stereochemistry is closer to the expected geometry when the coordination number is 5, suggesting that this is the coordination number towards which the chlorides tend when they interact with proteins. Conclusions The results of these analyses are useful in interpreting, describing, and validating new protein crystal structures that contain chloride anions. PMID:25928393
Buried chloride stereochemistry in the Protein Data Bank.
Carugo, Oliviero
2014-09-23
Despite the chloride anion is involved in fundamental biological processes, its interactions with proteins are little known. In particular, we lack a systematic survey of its coordination spheres. The analysis of a non-redundant set (pairwise sequence identity < 30%) of 1739 high resolution (<2 Å) crystal structures that contain at least one chloride anion shows that the first coordination spheres of the chlorides are essentially constituted by hydrogen bond donors. Amongst the side-chains positively charged, arginine interacts with chlorides much more frequently than lysine. Although the most common coordination number is 4, the coordination stereochemistry is closer to the expected geometry when the coordination number is 5, suggesting that this is the coordination number towards which the chlorides tend when they interact with proteins. The results of these analyses are useful in interpreting, describing, and validating new protein crystal structures that contain chloride anions.
Mitani, Kurie; Narimatsu, Shizuo; Izushi, Fumio; Kataoka, Hiroyuki
2003-07-14
A simple and rapid method was developed for analyzing contamination of endocrine disruptors in liquid medicines and intravenous injection solutions. Endocrine disrupting compounds such as bisphenol A (BPA), alkylphenols and phthalates were quantitated by on-line in-tube solid-phase microextraction coupled with high performance liquid chromatography (in-tube SPME/HPLC) with UV detection. The liquid medicines and intravenous injection solutions could be used directly without any pretreatment, and the BPA, alkylphenols and phthalates in these solutions were automatically analyzed. The limits of quantification for these compounds were 1-10 ng/ml. Recoveries of these compounds spiked to the intravenous injection solutions was over 80%, except for some phthalates. Di-n-butyl phthalate (DBP) was detected at a concentration of 7-60 ng/ml in most intravenous injection solutions in plastic containers, but it was not detected in solutions in glass bottles. Diethyl phthalate, di-n-propyl phthalate, DBP and di-2-ethylhexyl phthalate (DEHP) were also detected in syrup, lotion and eye drops in plastic containers. On the other hand, BPA and alkylphenols were not detected at all in these solutions. DEHP contamination from an administration set increased when total vitamin formulation was added to the infusion solution. DEHP was easily leached from polyvinyl chloride tubing by polysorbate 80. The in-tube SPME/HPLC method is simple, rapid and automatic, and it provides a useful tool for the screening and determination of endocrine disruptor contamination in liquid medicines and intravenous injection solutions.
Adhesion of Streptococcus sanguis CH3 to polymers with different surface free energies.
van Pelt, A W; Weerkamp, A H; Uyen, M H; Busscher, H J; de Jong, H P; Arends, J
1985-01-01
The adhesion of the oral bacterium Streptococcus sanguis CH3 to various polymeric surfaces with surface free energies (gamma s) ranging from 22 to 141 erg cm-2 was investigated. Suspensions containing nine different bacterial concentrations (2.5 X 10(7) to 2.5 X 10(9) cells per ml) were used. After adhesion for 1 h at 21 degrees C and a standardized rinsing procedure, the number of attached bacteria per square centimeter (nb) was determined by scanning electron microscopy. The highest number of bacteria was consistently found on polytetrafluorethylene (gamma s = 22 erg cm-2), and the lowest number was found on glass (gamma s = 141 erg cm-2) at all bacterial concentrations tested. The overall negative correlation between nb and gamma s was weak. However, the slope of the line showing this decrease, calculated from an assumed linear relationship between nb and gamma s, appeared to depend strongly on the bacterial concentration and increased with increasing numbers of bacteria in the suspension. Analysis of the data for each separate polymer showed that the numbers of attached cells on polyvinyl chloride and polypropylene were higher but that those on polycarbonate were lower than would be expected on basis of a linear relationship between nb and gamma s. Desorption experiments were performed by first allowing the bacteria to attach to substrata for 1 h, after which the substrata and attached bacteria were removed to bacterial suspensions containing 10-fold lower bacterial concentrations.(ABSTRACT TRUNCATED AT 250 WORDS) Images PMID:4004241
Bonggotgetsakul, Ya Ya Nutchapurida; Cattrall, Robert W; Kolev, Spas D
2015-12-08
Poly(vinyl chloride) (PVC) based polymer inclusion membranes (PIMs), with different concentrations of Cyphos® IL 104 as the membrane extractant/carrier, were studied for their ability to extract Au(III) from hydrochloric acid solutions. Some of the PIMs also contained one of the following plasticizers or modifiers: 2-nitrophenyloctyl ether, dioctylphthalate, 1-dodecanol, 1-tetradecanol, or tri(2-ethylhexyl) phosphate. The best performance, in terms of extraction rate and amount of Au(III) extracted, was exhibited by a PIM consisting of 25 wt% Cyphos(®) IL 104, 5 wt% 1-dodecanol, and 70 wt% PVC. An almost complete back-extraction of the Au(III) extracted from this membrane was achieved by using a 0.10 mol L(-1) Na₂SO₃ receiver solution at pH 8. The stoichiometry of the extracted Au(III)/Cyphos® IL 104 adduct was determined as [P]⁺ [AuCl₄](-) H⁺ [PO₂](-) where [P]⁺ and [PO₂](-) represent trihexyl(tetradecyl) phosphonium and bis(2,4,4-trimethylpentyl) phosphinate ions, respectively. Back-extraction of Au(III) is suggested to occur by reduction of Au(III) to Au(I), with the formation of the species [Au(SO₃)₂](3-) in the aqueous receiver solution. Loss of 1-dodecanol from the newly developed PIM to the aqueous solutions in contact with it was observed, which indicated that this membrane was suitable for single use in the efficient recovery of Au(III) from hydrochloric acid solutions of electronic scrap or recycled jewelry.
MACHADO, Carlos Eduardo Palhares; GUEDES, Carlos Gramani
2011-01-01
Objectives This study investigated the possible interactions between three addition silicone materials (Express®, Aquasil Ultra® and Adsil®), three hemostatic agents (ferric sulfate, StatGel FS®; aluminum sulfate, GelCord®; and aluminum chloride, Hemostop®) and gingival retraction cords previously handled with latex gloves to determine whether direct contact with medicaments or indirect contamination by latex in conditions similar to those found in clinical practice inhibit or affect the setting of the impression materials. Material and Methods A portable device for the simultaneous test of several specimens was specifically developed for this study. Polymerization inhibition was analyzed by examination of the impressions and the molded surface. Ten trials were performed for each addition silicone material used in the study, at a total of 240 study samples. Results All the samples tested (N=240) were nonreactive regardless of the type of combination used. Conclusions Aluminum sulfate, ferric sulfate and aluminum chloride hemostatic solutions did not show any inhibitory potential on the addition silicone samples under study, and there were no changes in polymerization as a result of contact between addition silicone and retraction cords handled with latex gloves. PMID:22230998
Yuan, Wenjin; Lu, Yunhua; Xu, Shiai
2016-01-01
A new titanate coupling agent synthesized from polyethylene glycol (PEG), isooctyl alcohol, and phosphorus pentoxide (P2O5) was used for the modification of calcium sulfate whiskers (CSWs) and the preparation of high-performance CSW/poly(vinyl chloride) (PVC) composites. The titanate coupling agent (sTi) and the modified CSWs (sTi–CSW) were characterized by Fourier transform infrared (FTIR) spectroscopy, and the mechanical, dynamic mechanical, and heat resistant properties and thermostability of sTi–CSW/PVC and CSW/PVC composites were compared. The results show that sTi–CSW/PVC composite with 10 wt. % whisker content has the best performance, and its tensile strength, Young’s modulus, elongation at break, break strength, and impact strength are 67.2 MPa, 1926 MPa, 233%, 51.1 MPa, and 12.75 KJ·m−2, with an increase of 20.9%, 11.5%, 145.3%, 24.6%, and 65.4% compared to that of CSW/PVC composite at the same whisker content. As the whisker content increases, the storage modulus increases, the Vicat softening temperature decreases slightly, and the glass transition temperature increases at first and then decreases. PMID:28773748
Machado, Carlos Eduardo Palhares; Guedes, Carlos Gramani
2011-01-01
This study investigated the possible interactions between three addition silicone materials (Express®, Aquasil Ultra® and Adsil®), three hemostatic agents (ferric sulfate, StatGel FS®; aluminum sulfate, GelCord®; and aluminum chloride, Hemostop®) and gingival retraction cords previously handled with latex gloves to determine whether direct contact with medicaments or indirect contamination by latex in conditions similar to those found in clinical practice inhibit or affect the setting of the impression materials. A portable device for the simultaneous test of several specimens was specifically developed for this study. Polymerization inhibition was analyzed by examination of the impressions and the molded surface. Ten trials were performed for each addition silicone material used in the study, at a total of 240 study samples. All the samples tested (N=240) were nonreactive regardless of the type of combination used. Aluminum sulfate, ferric sulfate and aluminum chloride hemostatic solutions did not show any inhibitory potential on the addition silicone samples under study, and there were no changes in polymerization as a result of contact between addition silicone and retraction cords handled with latex gloves.
Barrow, C S; Alarie, Y; Stock, M F
1978-01-01
A decrease in respiratory rate in mice during exposure to irritating airborne chemicals has been utilized as a response parameter to characterize the degree of upper respiratory tract irritation (sensory irritation) to the thermal decomposition products of various polymers. These included polystyrene, polyvinyl chloride, flexible polyurethane foam, polytetrafluorethylene, a fiber glass reinforced polyester resin, and Douglas Fir. Each of the materials was thermally decomposed in a low-mass vertical furnace in an air atmosphere at a programmed heating rate of 20 degrees C/min. Mice, in groups of four, were exposed to graded concentrations of the thermal decomposition products of each of the above materials. Dose-response curves were obtained by utilizing the maximum percent decrease in respiratory rate as the response parameter during each exposure. Comparison of these dose-response curves with other sensory irritants such as chlorine, ammonia, hydrogen chloride, sulfur dioxide, and toluene diisocyanate gave an indication of the sensory irrtation potential of the thermal decomposition products of these various polymers versus that of well-known single airborne chemical irritants. Total stress and incapacitation of the organism during exposure to sensory irritants such as from the thermal decomposition products of synthetic polymers is discussed.
Lacey, Steven; Alexander, Barbara M; Baxter, C Stuart
2014-01-01
Chemical exposures may be responsible for firefighters' elevated incidences of cancer and cardiovascular disease. This study characterized semivolatile chemical contamination on firefighter personal protective clothing to assess exposure of firefighters to these chemicals. Samples from used firefighter protective clothing, including gloves, hood, and one coat wristlet, were extracted with methylene chloride and analyzed by EPA method 8270 for semivolatile contaminants, including 20 polycyclic aromatic hydrocarbons (PAHs) and 6 phthalate diesters. Twenty-two of the chemicals of interest were found on at least one clothing swatch. Only di-(2-ethylhexyl) phthalate (DEHP), a plasticizer, added to polyvinyl chloride (PVC) to increase flexibility, was found on every swatch. DEHP concentrations were the highest of any chemical measured, and were 52 to 875 times higher than any PAH concentration measured. DEHP was also detected on most items of unused firefighter personal protective clothing, although at much lower levels. These findings suggest that firefighters are exposed to high levels of DEHP, a probable human carcinogen, and at levels much higher than PAHs, the semivolatile toxic combustion products most extensively studied historically. Firefighter exposure to DEHP and other phthalate diesters therefore merits further study.
Instrument for Analysis of Greenland's Glacier Mills
NASA Technical Reports Server (NTRS)
Behar, Alberto E.; Matthews, Jaret B.; Tran, Hung B.; Steffen, Konrad; McGrath, Dan; Phillips, Thomas; Elliot, Andrew; OHern, Sean; Lutz, Colin; Martin, Sujita;
2010-01-01
A new instrument is used to study the inner workings of Greenland s glacier mills by riding the currents inside a glacier s moulin. The West Greenland Moulin Explorer instrument was deployed into a tubular shaft to autonomously record temperature, pressure, 3D acceleration, and location. It is built with a slightly positive buoyancy in order to assist in recovery. The unit is made up of several components. A 3-axis MEMS (microelectromechanical systems) accelerometer with 0.001-g resolution forms the base of the unit. A pressure transducer is added that is capable of withstanding 500 psi (=3.4 MPa), and surviving down to -40 C. An Iridium modem sends out data every 10 minutes. The location is traced by a GPS (Global Positioning System) unit. This GPS unit is also used for recovery after the mission. Power is provided by a high-capacity lithium thionyl chloride D-sized battery. The accelerometer is housed inside a cylindrical, foot-long (=30 cm) polyvinyl chloride (PVC) shell sealed at each end with acrylic. The pressure transducer is attached to one of these lids and a MEMS accelerometer to the other, recording 100 samples per second per axis.
Liu, Zhen; Wang, Han-Qing; Zhou, Yue-Yun; Zhang, Xiao-Dong; Liu, Jian-Wen
2017-07-01
The present study focuses on pretreatment of enhancing the properties of refuse-derived fuel (RDF) via low-temperature microwave irradiation. These improved properties include lower chlorine content, a more porous surface structure and better combustion characteristics. In this study, low-temperature microwave irradiation was carried out in a modified microwave apparatus and the range of temperature was set to be 220-300℃. We found that the microwave absorbability of RDF was enhanced after being partly carbonized. Moreover, with the increasing of the final temperature, the organochlorine removal ratio was greatly increased to 80% and the content of chlorine was dramatically decreased to an extremely low level. It was also interesting to find that the chlorine of RDF was mainly released as HCl rather than organic chloride volatiles. The finding is just the same as the polyvinyl chloride pyrolysis process. In addition, pores and channels emerged during the modifying operation and the modified RDF has better combustibility and combustion stability than traditional RDF. This work revealed that low-temperature modification of RDF via microwave irradiation is significant for enhancing the quality of RDF and avoiding HCl erosion of equipment substantially.
Sato, Harumi; Higashi, Noboru; Ikehata, Akifumi; Koide, Noriko; Ozaki, Yukihiro
2007-07-01
The aim of the present study is to propose a totally new technique for the utilization of far-ultraviolet (UV) spectroscopy in polymer thin film analysis. Far-UV spectra in the 120-300 nm region have been measured in situ for six kinds of commercial polymer wrap films by use of a novel type of far-UV spectrometer that does not need vacuum evaporation. These films can be straightforwardly classified into three groups, polyethylene (PE) films, polyvinyl chloride (PVC) films, and polyvinylidene chloride (PVDC) films, by using the raw spectra. The differences in the wavelength of the absorption band due to the sigma-sigma* transition of the C-C bond have been used for the classification of the six kinds of films. Using this method, it was easy to distinguish the three kinds of PE films and to separate the two kinds of PVDC films. Compared with other spectroscopic methods, the advantages of this technique include nondestructive analysis, easy spectral measurement, high sensitivity, and simple spectral analysis. The present study has demonstrated that far-UV spectroscopy is a very promising technique for polymer film analysis.
Mahakarnchanakul, W; Beuchat, L R
1999-03-15
A study was done to determine the influence of temperature on growth and toxin production characteristics of psychrotrophic and mesophilic strains of Bacillus cereus when inoculated into mashed potatoes and chicken gravy containing various concentrations of sodium chloride and held at temperatures different from those at which cells had been cultured. Logarithmic growth phase cells (10 h, 30 degrees C) of psychrotrophic (F3802A/84) and mesophilic (B4ac-1) strains of Bacillus cereus were inoculated into rehydrated commercially processed instant mashed potatoes and chicken gravy supplemented with 0, 2, or 4% sodium chloride. Growth, survival, and diarrheal toxin production in potatoes and gravy held at 30, 37, and 10 degrees C (strain F3802A/84) or 30, 40, and 10 degrees C (strain B4ac-1) were monitored. Both strains grew in both foods containing no added sodium chloride or 2% sodium chloride when held at 30, 37, or 40 degrees C for 2 days. Strain B4ac-1 grew better than strain F3802A/84 in foods containing 4% sodium chloride. Maximum amounts of enterotoxin (1024 ng/g) were produced by strain B4ac-1 in chicken gravy held at 30 and 40 degrees C. Strain F3802A/84 grew to populations of 7 log10 CFU/g in foods containing no added sodium chloride or 2% sodium chloride at 10 degrees C. Strain F3802A/84 produced the highest amount of enterotoxin (1024 ng/g) at 30 degrees C in chicken gravy containing 0.7 or 2% sodium chloride; however, little or low amounts of toxin (4-16 ng/g) were produced in chicken gravy at 10 degrees C. Compared to strain B4ac-1, cells of strain F3802A/84 subjected to a downward shift in incubation temperature (10 degrees C) grew more rapidly in chicken gravy. Strain B4ac-1 produced the highest amount of toxin (1024 ng/g) at 30 degrees C in gravy containing 4% sodium chloride and at 40 degrees C in gravy containing 0.7% sodium chloride. Toxin was not detected in inoculated mashed potatoes. Results of this study indicate that shifts in incubation temperature influence growth and toxin production by psychrotrophic and mesophilic strains of B. cereux differently. It is important to store pasteurized, ready-to-eat foods at a temperature low enough to prevent the growth of B. cereus.
21 CFR 184.1845 - Stannous chloride (anhydrous and dihydrated).
Code of Federal Regulations, 2010 CFR
2010-04-01
.... Anhydrous stannous chloride (SnCl2, CAS Reg. No. 7772-99-8) is the chloride salt of metallic tin. It is prepared by reacting molten tin with either chlorine or gaseous tin tetrachloride. Dihydrated stannous chloride (SnCl2·2H2O, CAS Reg. No. 10025-0969-091) is the chloride salt of metallic tin that contains two...
21 CFR 184.1845 - Stannous chloride (anhydrous and dihydrated).
Code of Federal Regulations, 2013 CFR
2013-04-01
.... Anhydrous stannous chloride (SnCl2, CAS Reg. No. 7772-99-8) is the chloride salt of metallic tin. It is prepared by reacting molten tin with either chlorine or gaseous tin tetrachloride. Dihydrated stannous chloride (SnCl2·2H2O, CAS Reg. No. 10025-69-1) is the chloride salt of metallic tin that contains two...
21 CFR 184.1845 - Stannous chloride (anhydrous and dihydrated).
Code of Federal Regulations, 2011 CFR
2011-04-01
.... Anhydrous stannous chloride (SnCl2, CAS Reg. No. 7772-99-8) is the chloride salt of metallic tin. It is prepared by reacting molten tin with either chlorine or gaseous tin tetrachloride. Dihydrated stannous chloride (SnCl2·2H2O, CAS Reg. No. 10025-0969-091) is the chloride salt of metallic tin that contains two...
21 CFR 184.1845 - Stannous chloride (anhydrous and dihydrated).
Code of Federal Regulations, 2012 CFR
2012-04-01
.... Anhydrous stannous chloride (SnCl2, CAS Reg. No. 7772-99-8) is the chloride salt of metallic tin. It is prepared by reacting molten tin with either chlorine or gaseous tin tetrachloride. Dihydrated stannous chloride (SnCl2·2H2O, CAS Reg. No. 10025-69-1) is the chloride salt of metallic tin that contains two...
21 CFR 520.310 - Caramiphen ethanedisulfonate and ammonium chloride tablets.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Caramiphen ethanedisulfonate and ammonium chloride... § 520.310 Caramiphen ethanedisulfonate and ammonium chloride tablets. (a) Specifications. Each tablet contains 10 milligrams of 5st caramiphen ethanedisulfonate and 80 milligrams of ammonium chloride.1 1 These...
REMOVAL OF CHLORIDE FROM AQUEOUS SOLUTIONS
Schulz, W.W.
1959-08-01
The removal of chlorides from aqueons solutions is described. The process involves contacting the aqueous chloride containing solution with a benzene solution about 0.005 M in phenyl mercuric acetate whereby the chloride anions are taken up by the organic phase and separating the organic phase from the aqueous solutions.
Mori, Masanobu; Yamamoto, Tsukasa; Kaseda, Maki; Yamada, Sachiko; Itabashi, Hideyuki
2012-03-01
A combination of polyvinyl alcohol chemically coated capillary (PVA capillary) and background electrolyte (BGE) with ion-pair reagent (hexamethonium dichloride, HMC) was used on capillary ion electrophoresis-UV detection (CIE-UV) for analysis of Br⁻, I⁻, NO₂⁻, NO₃⁻, SCN⁻ and uric acid in human saliva. The PVA capillary prepared in our laboratory minimized electro-osmotic flow (EOF) at the BGE in pH 3-10, and did not affect the UV detection at 210 nm by the PVA-layer on capillary wall. Therefore, use of the PVA capillary was suitable for sensitive UV detection for analyte anions, as well as suppression of protein adsorption. In this study, we optimized the BGE of 10 mM phosphate plus 10 mM HMC with applying a voltage of -15 kV. HMC as an additive to BGE could manipulate the electrophoretic mobility of anions, without electrostatic adsorption to the PVA capillary. The CIE-UV could separate and determine analyte anions in human saliva containing proteins by the direct injection without pretreatments such as dilution or deproteinization within 13 min. The relative standard deviations (n=10) were ranged of 0.5-1.6% in migration times, 2.2-6.8% in peak heights and 2.8-8.4% in peak areas. The limits of detection (S/N=3) were ranged of 3.42-6.87 μM. The peak height of anions in this system was gradually decreased through the successive injections of saliva samples, but the problem was successfully solved by periodically conditioning the PVA capillary. The quantifiability of anions in human saliva samples by the CIE-UV was evaluated through the recoveries by standard addition methods and comparison of other representative analytical methods, as well as identification by ion chromatography (IC). From the anion analyses in 12 different saliva samples, the CIE-UV demonstrated that can obtain obvious differences in concentrations of SCN⁻ between of smoker and non-smoker and those of uric acid between male and female with satisfactory results. Copyright © 2012 Elsevier B.V. All rights reserved.
Degradation of PVC/HC blends. II. Terrestrial plant growth test.
Pascu, Mihaela; Agafiţei, Gabriela-Elena; Profire, Lenuţa; Vasile, Cornelia
2009-01-01
The behavior at degradation by soil burial of some plasticized polyvinyl chloride (PVC) based blends with a variable content of hydrolyzed collagen (HC) has been followed. The modifications induced in the environment by the polymer systems (pH variation, physiologic state of the plants, assimilatory pigments) were studied. Using the growth test of the terrestrial plants, we followed the development of Triticum (wheat), Helianthus annus minimus (little sunflower), Pisum sativum (pea), and Vicia X hybrida hort, during a vegetation cycle. After the harvest, for each plant, the quantities of chlorophyll and carotenoidic pigments and of trace- and macroelements were determined. It was proved that, in the presence of polymer blends, the plants do not suffer morphological and physiological modifications, the products released in the culture soil being not toxic for the plants growth.
Applications and societal benefits of plastics.
Andrady, Anthony L; Neal, Mike A
2009-07-27
This article explains the history, from 1600 BC to 2008, of materials that are today termed 'plastics'. It includes production volumes and current consumption patterns of five main commodity plastics: polypropylene, polyethylene, polyvinyl chloride, polystyrene and polyethylene terephthalate. The use of additives to modify the properties of these plastics and any associated safety, in use, issues for the resulting polymeric materials are described. A comparison is made with the thermal and barrier properties of other materials to demonstrate the versatility of plastics. Societal benefits for health, safety, energy saving and material conservation are described, and the particular advantages of plastics in society are outlined. Concerns relating to littering and trends in recycling of plastics are also described. Finally, we give predictions for some of the potential applications of plastic over the next 20 years.
Applications and societal benefits of plastics
Andrady, Anthony L.; Neal, Mike A.
2009-01-01
This article explains the history, from 1600 BC to 2008, of materials that are today termed ‘plastics’. It includes production volumes and current consumption patterns of five main commodity plastics: polypropylene, polyethylene, polyvinyl chloride, polystyrene and polyethylene terephthalate. The use of additives to modify the properties of these plastics and any associated safety, in use, issues for the resulting polymeric materials are described. A comparison is made with the thermal and barrier properties of other materials to demonstrate the versatility of plastics. Societal benefits for health, safety, energy saving and material conservation are described, and the particular advantages of plastics in society are outlined. Concerns relating to littering and trends in recycling of plastics are also described. Finally, we give predictions for some of the potential applications of plastic over the next 20 years. PMID:19528050
Park, Kang Hoon; Chung, Dong June
2015-01-01
Di-2-ethylhexyl phthalate (DEHP) are added to poly(vinyl chloride)(PVC) infusion tubes as a plasticizer to ensure tube flexibility. In addition to previously reported disadvantages of DEHP, released DEHP molecules from PVC tubes can easily interact with surfactants in anticancer drug solutions (i.e., polysorbate 80 for Taxotere®-Inj) and reduce the solubility of docetaxel in aqueous solution during anticancer drug administration. In this study, we investigated the in vitro stability of docetaxel in a 0.9% saline solution under an intravenous administration condition using a PVC tube (high DEHP content) and non-PVC infused tube. The docetaxel solution circulating through the non-PVC tube had better solution stability than through the PVC tube(high DEHP content).
[Experimental rationale for a procedure for correction of the residual cavity in hydatidectomy].
Biriukov, Iu V; Streliaeva, A V; Sadykov, R V; Lazareva, N B; Sadykov, V M; Chebyshev, N V
2010-01-01
Thirty-six piglets (15 days old) were inoculated with Echinococcus according to the authors' procedure. Hepatic hydatid cyst growth in the piglets was ultrasonographically monitored 3 months after inoculation. In 15 piglets, the size of hepatic hydatid cysts was as high as 6.5 x 8.5 cm 5 months after infection. The cavity of larvocystic fibrous capsule was eliminated, by inverting the resection margins inward with interrupted catgut sutures. For content aspiration, the cystic bed was occasionally drained by a polyvinyl chloride tube with two side holes, which was brought outward through an individual incision. Thesubhepatic area was also drained by a "cigar" tampon through an individual incision. The wound healed in layers, tightly. Marginal resection of the liver was performed to stimulate regenerative processes in the resected area.
Two-week studies of survivors from exposures to pyrolysis gases
NASA Technical Reports Server (NTRS)
Bucci, T. J.; Hilado, C. J.; Marcussen, W. H.; Furst, A.
1978-01-01
Swiss Webster male mice which had survived near-lethal concentrations of pyrolysis gases from a variety of polymeric materials were killed two weeks after exposure, and the lungs, heart, liver, kidney, and spleen were examined. Microscopic examination revealed no significant effects on the liver, kidney, and spleen, while the effect on lungs could not be determined because of the high level of pathology in both experimental and control animals. The polymeric materials which were pyrolyzed were polyethylene, ABS, polycarbonate, polyaryl sulfone, polyether sulfone, polyphenylene sulfide, modified polyphenylene oxide, chlorinated polyvinyl chloride, polyvinylidene fluoride, and fluorene polycarbonate. It is suggested that tissue specimens should be examined 24 or 48 hr after exposure rather than 2 wks after exposure, since the 2 wk period permits healing to occur.
Polymer nanocomposite dielectric and electrical properties with quantum dots nanofiller
NASA Astrophysics Data System (ADS)
Ahmed, R. M.; Morsi, R. M. M.
2017-10-01
Nanocomposite films of different contents of CdSe/ZnS quantum dots nanoparticles embedded in hosting matrix of polyvinyl chloride (PVC) were prepared by simple solution casting method. Electrical and dielectric properties of nanocomposites films were investigated in the temperature range 323-393 (K) and at frequencies (50-2000) kHz. The frequency dependence of AC conductivity was following the universal power law. The values of the frequency exponent, s, revealed that the conduction mechanism at low temperature is considered by small polaron tunneling model, whereas at high temperature, it is related to CBH model. The activation energy values (ΔE) were depending on nanoparticle concentration as well as frequency. Also, X-ray diffraction (XRD) enabled approximately estimating the average particle size of the nanoparticles incorporated in PVC.
21 CFR 175.270 - Poly(vinyl fluoride) resins.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 3 2010-04-01 2009-04-01 true Poly(vinyl fluoride) resins. 175.270 Section 175... Substances for Use as Components of Coatings § 175.270 Poly(vinyl fluoride) resins. Poly(vinyl fluoride... the purpose of this section, poly(vinyl fluoride) resins consist of basic resins produced by the...
21 CFR 175.270 - Poly(vinyl fluoride) resins.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 3 2011-04-01 2011-04-01 false Poly(vinyl fluoride) resins. 175.270 Section 175... Substances for Use as Components of Coatings § 175.270 Poly(vinyl fluoride) resins. Poly(vinyl fluoride... the purpose of this section, poly(vinyl fluoride) resins consist of basic resins produced by the...
Vote, D J; Platter, W J; Tatum, J D; Schmidt, G R; Belk, K E; Smith, G C; Speer, N C
2000-04-01
Beef strip loins (46 U.S. Choice loins and 49 U.S. Select loins) were used to evaluate the potential for enhancing beef tenderness, juiciness, and flavor by injecting fresh cuts with solutions containing sodium tripolyphosphate, sodium lactate, and sodium chloride. One half of each loin served as an untreated control, and the other half was injected with either distilled water (110% of raw weight) or a solution containing phosphate/lactate/chloride solution (107.5, 110, 112.5, or 115% of raw weight). All phosphate/lactate/chloride solutions were formulated to produce injected product concentrations of .25% sodium tripolyphosphate, .5% sodium chloride, and 2.5% sodium lactate. Ten additional U.S. Select loins were injected to 110% of raw weight with a phosphate-only solution (final product concentration of .25% sodium tripolyphosphate) for comparison with Select loins injected to 110% with phosphate/lactate/chloride and with distilled water. Steaks from each control and treated loin section were cooked to two final internal temperatures (66 degrees C and 77 degrees C) for sensory panel evaluation and shear force measurement. Injection of subprimal cuts with phosphate/lactate/chloride solutions improved tenderness (P < .05), juiciness (P < .05), and cooked beef flavor (P < .10) of strip loin steaks and was especially effective for maintaining tenderness and juiciness of steaks cooked to the higher final internal temperature. Injection of Select loins with a solution containing only sodium tripolyphosphate was not effective for improving beef tenderness or juiciness and tended to impart off-flavors characterized by sensory panelists as soapy and sour. Injection of fresh cuts with phosphate/lactate/chloride solutions could assist the beef industry's efforts to improve product quality and consistency.